Renovating Residential HVAC Systems HVAC Systems  

E-Print Network [OSTI]

- 1 - LBNL 57406 Renovating Residential HVAC Systems HVAC Systems J.A. McWilliams and I.S. Walker and Air Conditioning), and Stacy Hunt and Ananda Harzell (IBACOS). #12;- 3 - Renovating Residential HVAC Guideline for Residential HVAC Retrofits (http

2

Optimized Fan Control In Variable Air Volume HVAC Systems Using Static Pressure Resets: Strategy Selection and Savings Analysis.  

E-Print Network [OSTI]

??The potential of static pressure reset (SPR) control to save fan energy in variable air volume HVAC systems has been well documented. Current research has… (more)

Kimla, John

2010-01-01T23:59:59.000Z

3

Optimized Fan Control In Variable Air Volume HVAC Systems Using Static Pressure Resets: Strategy Selection and Savings Analysis  

E-Print Network [OSTI]

The potential of static pressure reset (SPR) control to save fan energy in variable air volume HVAC systems has been well documented. Current research has focused on the creation of reset strategies depending on specific system features...

Kimla, John

2010-07-14T23:59:59.000Z

4

Advanced HVAC Systems | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

HVAC Systems Advanced HVAC Systems Lead Performer: Oak Ridge National Laboratory - Oak Ridge, TN Partners: -- Indian Institute of Technology Bombay - Maharashtra, India -- Malviya...

5

Neuro-optimal operation of a variable air volume HVAC&R system  

Science Journals Connector (OSTI)

Low operational efficiency especially under partial load conditions and poor control are some reasons for high energy consumption of heating, ventilation, air conditioning and refrigeration (HVAC&R) systems. To improve energy efficiency, HVAC&R systems should be efficiently operated to maintain a desired indoor environment under dynamic ambient and indoor conditions. This study proposes a neural network based optimal supervisory operation strategy to find the optimal set points for chilled water supply temperature, discharge air temperature and VAV system fan static pressure such that the indoor environment is maintained with the least chiller and fan energy consumption. To achieve this objective, a dynamic system model is developed first to simulate the system behavior under different control schemes and operating conditions. A multi-layer feed forward neural network is constructed and trained in unsupervised mode to minimize the cost function which is comprised of overall energy cost and penalty cost when one or more constraints are violated. After training, the network is implemented as a supervisory controller to compute the optimal settings for the system. Simulation results show that compared to the conventional night reset operation scheme, the optimal operation scheme saves around 10% energy under full load condition and 19% energy under partial load conditions.

Min Ning; M. Zaheeruddin

2010-01-01T23:59:59.000Z

6

VOLUME 16, NUMBER 3 HVAC&R RESEARCH MAY 2010 The Effects of Filtration on  

E-Print Network [OSTI]

VOLUME 16, NUMBER 3 HVAC&R RESEARCH MAY 2010 273 The Effects of Filtration on Pressure Drop and Energy Consumption in Residential HVAC Systems (RP-1299) Brent Stephens Atila Novoselac, PhD Jeffrey A of high-efficiency HVAC filters is a common strategy to control exposure to airborne particulate matter

Siegel, Jeffrey

7

SIMULATION OF RESIDENTIAL HVAC SYSTEM PERFORMANCE  

E-Print Network [OSTI]

1 LBNL-47622 SIMULATION OF RESIDENTIAL HVAC SYSTEM PERFORMANCE Walker, I., Siegel, J ..................................................... 9 #12;3 ABSTRACT In many parts of North America residential HVAC systems are installed outside of the simulations is that they are dynamic - which accounts for cyclic losses from the HVAC system and the effect

8

CALIFORNIA ENERGY Small HVAC System Design Guide  

E-Print Network [OSTI]

CALIFORNIA ENERGY COMMISSION Small HVAC System Design Guide DESIGNGUIDELINES October 2003 500;#12;Small HVAC System Design Guide Acknowledgements i Acknowledgements The products and outcomes presented; Darren Goody, PECI, Design Guide review. #12;Small HVAC System Design Guide Preface ii Preface The Small

9

Energirigtige pumpekoblinger i HVAC-systemer  

E-Print Network [OSTI]

Energirigtige pumpekoblinger i HVAC-systemer PSO 2003 - FORSKNING & UDVIKLING I EFFEKTIV energieffektive HVAC-aggregater #12;InformationomProjektnr.:335-021 PROCESSEN: Projektet er gennemført af en reguleringsprincipper, mens Exhausto har leveret HVAC-aggregat og knowhow inden for klimasystemer. Grundfos

10

Measuring Advances in HVAC Distribution System Design  

E-Print Network [OSTI]

Advances in HV AC Distribution System Design Ellen FranconiAdvances in HVAC Distribution System Design Ellen Franconisavings result from distribution system design improvements,

Franconi, E.

2011-01-01T23:59:59.000Z

11

Modeling and Identification for HVAC Systems.  

E-Print Network [OSTI]

?? Heating, Ventilation and Air Conditioning (HVAC) systems consist of all the equipment that control the conditions and distribution of indoor air. Indoor air must… (more)

Scotton, Francesco

2012-01-01T23:59:59.000Z

12

Integration of HVAC System Design with Simplified Duct Distribution...  

Broader source: Energy.gov (indexed) [DOE]

Integration of HVAC System Design with Simplified Duct Distribution - Building America Top Innovation Integration of HVAC System Design with Simplified Duct Distribution - Building...

13

System dynamics based models for selecting HVAC systems for office buildings: a life cycle assessment from carbon emissions perspective.  

E-Print Network [OSTI]

??This study aims to explore the life cycle environmental impacts of typical heating ventilation and air condition (HVAC) systems including variable air volume (VAV) system,… (more)

Chen, S

2011-01-01T23:59:59.000Z

14

Salsbury and Diamond: Automated Testing of HVAC Systems for Commissioning -1 -Automated Testing of HVAC Systems for Commissioning  

E-Print Network [OSTI]

and Diamond: Automated Testing of HVAC Systems for Commissioning - 1 - Automated Testing of HVAC Systems This paper describes an approach to the automation of the commissioning of HVAC systems. The approach of many HVAC systems is limited more by poor installation, commissioning, and maintenance than by poor

15

System Optimization - The Global Approach to HVAC Control  

E-Print Network [OSTI]

System Optimization is a new approach to HVAC control as implemented by Energy Management Control Systems. System Optimization is defined as electronic building control strategies which treat a building's HVAC components as a complete energy...

Thielman, D. E.

1984-01-01T23:59:59.000Z

16

Review of modeling methods for HVAC systems  

Science Journals Connector (OSTI)

Abstract This work presents the literature review of the methods used to model the heating, ventilation, and air conditioning (HVAC) systems. The model development is necessary for the study of the energy consumption of HVAC systems. Models are also required to simulate the different supervisory and local loop control strategies to improve the energy consumption efficiency. HVAC systems have complex structures consisting of heat and mass transfer equipment such as chiller, boiler, heating/cooling coils, and supply air ducts. HVAC systems also consist of several sensors and controllers for regulating the controllable variables such as zone temperature, supply air temperature, supply air fan speed, duct static pressure, and chilled water temperature at their set-points. To predict the energy consumption by the HVAC systems accurately, one needs to model the individual components either from the measured data or based on the knowledge of the underlying physical phenomenon. This results in three broad classes of the models known as data driven, physics based, and grey box models. In this paper, major data driven, physics based, and grey box modeling techniques reported in the recent literature are reviewed.

Abdul Afram; Farrokh Janabi-Sharifi

2014-01-01T23:59:59.000Z

17

Implementation and main results Ecient Management of HVAC Systems  

E-Print Network [OSTI]

water to remove heat from the air in the building. In HVAC system equipped with chillers, the electrical #12;Motivation Implementation and main results HVAC Systems Multiple-chiller systems Heating, Ventilation and Air-Conditioning System Heating, Ventilation and Air Conditioning Systems (HVAC) represents

Schenato, Luca

18

A PDI for your HVAC System  

Broader source: Energy.gov (indexed) [DOE]

8/3/2012 Technical Approach Develop a PDI for HVAC PDI focus is on Inspecting Installation - a $10 Chinese sweatshop t-shirt gets a QA/QC sticker, why not a $10k HVAC system? Develop & require diagnostics that confirm good installations: - Air flow, duct leakage, refrigerant charge, delivered temperatures, system pressures, filter requirements, fan power, noise - On board diagnostics (OBD) for flow, pressures, fan power, charge Make it a warranty requirement, code requirement, permit requirement, etc. Recommended Guidance Develop the PDI checklist and label (include target and system test results) - External Tests: duct leaks - Internal Tests: OBD for system pressures, air flow, charge, fan power - Labels: Certify tight equipment

19

Theoretical Minimum Energy Use of a Building HVAC System  

E-Print Network [OSTI]

This paper investigates the theoretical minimum energy use required by the HVAC system in a particular code compliant office building. This limit might be viewed as the "Carnot Efficiency" for HVAC system. It assumes that all ventilation and air...

Tanskyi, O.

2011-01-01T23:59:59.000Z

20

Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings  

E-Print Network [OSTI]

Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings Tom Rogg REU Student to assist HVAC has the potential to significantly reduce life cycle cost and energy consumption and electrical system that will tie thermostats to controlled valves in the actual HVAC system. Based on results

Mountziaris, T. J.

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Implementation of a Scenario-based MPC for HVAC Systems  

E-Print Network [OSTI]

Implementation of a Scenario-based MPC for HVAC Systems: an Experimental Case Study Alessandra, Ventilation and Air Conditioning (HVAC) systems play a fundamental role in maintaining acceptable thermal energy savings potential. Developing effective MPC-based control strategies for HVAC systems

Johansson, Karl Henrik

22

Practical Approach in Design of HVAC Systems Utilizing Geothermal Energy  

Science Journals Connector (OSTI)

Geothermal is the Earth’s thermal energy. In recent years geothermal energy has been utilized for generation of electricity, heating and air conditioning (HVAC). Geothermal HVAC systems are cost effective, energy

M. Fathizadeh; D. Seims

2014-01-01T23:59:59.000Z

23

Long Range Passive UHF RFID System Using HVAC Ducts  

E-Print Network [OSTI]

INVITED P A P E R Long Range Passive UHF RFID System Using HVAC Ducts To provide a potential communications channel, HVAC ducts can function as electromagnetic waveguides; a 30-m read range has been-conditioning (HVAC) ducts as a potential communication channel between passive ultrahigh-frequency (UHF) radio

Hochberg, Michael

24

Pitfalls in Building and HVAC Systems  

E-Print Network [OSTI]

the summer savings. ? Consider all forms of savings, not just en ergy. Opportunities are often missed be cause only energy savings are consideted. For example, the installation of extetior wall insulation or aluminum thermopane win dows result in a...PITFALLS IN BUILDING AND HVAC SYSTEMS B. N. Gidwani, P.E. Roy F. Weston, Inc. West Chester, Pennsylvania ABSTRACT The purpose of an energy audit is to identify and analyze areas of energy consumption and to pro pose methods of conservation...

Gidwani, B. N.

25

Applications of HVAC System Utilizing Building Thermal Mass in Japan  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Applications of HVAC System Utilizing Building Thermal Mass in Japan Applications of HVAC System Utilizing Building Thermal Mass in Japan Speaker(s): Katsuhiro Miura Date: January 27, 2012 - 10:00am Location: 90-3122 Seminar Host/Point of Contact: Michael Wetter Buildings have a large thermal capacity and it affects much on building thermal load for the HVAC system. The thermal mass can be utilized also to control the thermal load by storing thermal energy before HVAC operation. There are two ways to store thermal energy. One is by operating the HVAC system and the other is by natural ventilation, mainly at night. The latter could be combined with daily HVAC operation as a hybrid ventilation. Thermal mass storage is useful to decrease the hourly peak load and the daily thermal load and can be used for both cooling and heating purpose.

26

Fault Detection and Diagnosis in Building HVAC Systems.  

E-Print Network [OSTI]

??Building HVAC systems account for more than 30% of annual energy consumption in United States. However, it has become apparent that only in a small… (more)

Najafi, Massieh

2010-01-01T23:59:59.000Z

27

HVAC's Variable Refrigerant Flow (VRF) Technology  

E-Print Network [OSTI]

1 Comfort by Design Steve Jones Commercial Sales Manager for Mitsubishi Southwest Business Unit HVAC?s Variable Refrigerant Flow (VRF) Technology HVAC Industry Overview HVAC Market Dollar Volume $18 Billion Source:;NABH Research....2M Systems Ductless is a small percent of the U.S. HVAC market but current building and energy usage trends indicate a large growth opportunity Determining the Proper Application Worldwide Usage-Opportunity Window Unitary Chillers...

Jones, S.

2012-01-01T23:59:59.000Z

28

Improving the Efficiency of Light-Duty Vehicle HVAC Systems using...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Light-Duty Vehicle HVAC Systems using Zonal Thermoelectric Devices and Comfort Modeling Improving the Efficiency of Light-Duty Vehicle HVAC Systems using Zonal Thermoelectric...

29

A Scenario-based Predictive Control Approach to Building HVAC Management Systems  

E-Print Network [OSTI]

A Scenario-based Predictive Control Approach to Building HVAC Management Systems Alessandra Parisio and Air Conditioning (HVAC) systems while minimizing the overall energy use. The strategy uses

Johansson, Karl Henrik

30

Energy efficient HVAC system features thermal storage and heat recovery  

SciTech Connect (OSTI)

This article describes a HVAC system designed to efficiently condition a medical center. The topics of the article include energy efficient design of the HVAC system, incentive rebate program by the local utility, indoor air quality, innovative design features, operations and maintenance, payback and life cycle cost analysis results, and energy consumption.

Bard, E.M. (Bard, Rao + Athanas Consulting Engineering Inc., Boston, MA (United States))

1994-03-01T23:59:59.000Z

31

A Fault Detection and Diagnosis Method for HVAC Systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

A Fault Detection and Diagnosis Method for HVAC Systems A Fault Detection and Diagnosis Method for HVAC Systems Speaker(s): Peng Xu Date: December 2, 2002 - 12:00pm Location: Bldg. 90 There is a growing consensus that most buildings do not perform as well as intended and that faults in HVAC systems are widespread in commercial buildings. An automated fault detection and diagnosis tool for HVAC systems is being developed, based on an integrated, life-cycle, approach to commissioning and performance monitoring. The tool uses component-level HVAC equipment models implemented in the SPARK equation-based simulation environment. The models are configured using design information and component manufacturers' data and then fine-tuned to match the actual performance of the equipment by using data measured during functional tests

32

HVAC & Building Management Control System Energy Efficiency Replacements  

SciTech Connect (OSTI)

The project objective was the replacement of an aging, un-repairable HVAC system which has grown inefficient and a huge energy consumer with low energy and efficient HVAC units, and installation of energy efficient building control technologies at City's YMCA Community Center.

Hernandez, Adriana

2012-09-21T23:59:59.000Z

33

Heat recovery and the economizer for HVAC systems  

SciTech Connect (OSTI)

This articles examines why a combined heat reclaim/economizer system with priority to heat reclaim operation is most likely to result in the least annual total HVAC energy. PC-based, hour-by-hour simulation programs evaluate annual HVAC energy requirements when using combined operation of heat reclaim and economizer cycle, while giving priority to operation of either one. These simulation programs also enable the design engineer to select the most viable heat reclaim and/or economizer system for any given type of HVAC system serving the building internal load level, building geographical location and other building/system variables.

Anantapantula, V.S. (Emerson Electric Co., St. Louis, MO (United States). Alco Controls Div.); Sauer, H.J. Jr. (Univ. of Missouri, Rolla, MO (United States))

1994-11-01T23:59:59.000Z

34

Commercial thermal distribution systems, Final report for CIEE/CEC  

E-Print Network [OSTI]

air-volume HVAC systems, static pressures across theIn VAY HVAC systems, the static pressures may likely changefor the Static Pressure Analysis Tool are: • HVAC schedule

Xu, T.

2011-01-01T23:59:59.000Z

35

Thermal model of solar absorption HVAC systems  

SciTech Connect (OSTI)

This paper presents a thermal model that describes the performance of solar absorption HVAC systems. The model considers the collector array, the building cooling and heating loads, the absorption chiller and the high temperature storage. Heat losses from the storage tank and piping are included in the model. All of the results presented in the paper are for an array of flat plate solar collectors with black chrome (selective surface) absorber plates. The collector efficiency equation is used to calculate the useful heat output from the array. The storage is modeled as a non-stratified tank with polyurethane foam insulation. The system is assumed to operate continuously providing air conditioning during the cooling season, space heating during the winter and hot water throughout the year. The amount of heat required to drive the chiller is determined from the coefficient of performance of the absorption cycle. Results are presented for a typical COP of 0.7. The cooling capacity of the chiller is a function of storage (generator) temperature. The nominal value is 190 F (88 C) and the range of values considered is 180 F (82 C) to 210 F (99 C). Typical building cooling and heating loads are determined as a function of ambient conditions. Performance results are presented for Sacramento, CA and Washington, D.C. The model described in the paper makes use of National Solar Radiation Data Base (NSRDB) data and results are presented for these two locations. The uncertainties in the NSRDB are estimated to be in a range of 6% to 9%. This is a significant improvement over previously available data. The model makes it possible to predict the performance of solar HVAC systems and calculate quantities such as solar fraction, storage temperature, heat losses and parasitic power for every hour of the period for which data are available.

Bergquam, J.B.; Brezner, J.M. [California State Univ., Sacramento, CA (United States). Dept. of Mechanical Engineering; [Bergquam Energy Systems, Sacramento, CA (United States)

1995-11-01T23:59:59.000Z

36

Index to Evaluate Energy Efficiency of the Building HVAC System  

E-Print Network [OSTI]

1An Index to Evaluate Energy Efficiency of the Entire Building HVAC System Presented by Dr. Claridge Date: 09/15/2014 ESL-IC-14-09-15 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14..., Beijing, China, September 14-17, 2014 3• Why we need the Energy/Load Ratio 1. Building 2. HVAC Systems 3. Common Index • Building sector consumes 40% of total energy usage in US (Residential buildings – 22%, Commercial building – 19%) • HVAC systems...

Wang, L.; Wang, L.; Claridge,D.

2014-01-01T23:59:59.000Z

37

Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable-Speed-Drive Chillers  

E-Print Network [OSTI]

LBNL-58636 Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable Efficient Cleanrooms Efficient HVAC Water Systems: Variable-Speed-Drive Chillers Tengfang Xu Contents HVAC.................................................................................................................................... 6 #12;HVAC Water Systems Variable-Speed-Drive Chillers Summary Cleanroom energy benchmarking data

38

OBSERVE: Occupancy-Based System for Efficient Reduction of HVAC Energy  

E-Print Network [OSTI]

OBSERVE: Occupancy-Based System for Efficient Reduction of HVAC Energy Varick L. Erickson, Miguel Á & control General Terms Algorithms, Machine Learning, Measurement Keywords Occupancy, HVAC, Ventilation for heating, ventilation, and air-conditioning (HVAC) systems[2]. Studies suggest that 15% to 25% of HVAC

Carreira-Perpiñán, Miguel Á.

39

A Web Based CBR System for HVAC Sales Support  

Science Journals Connector (OSTI)

This paper describes the implementation of a CBR system to support HVAC sales staff operating in remote locations. The ... the world wide web and uses the new standard of XML as a communications protocol between....

Dan Gardingen; Ian Watson

1999-01-01T23:59:59.000Z

40

Building HVAC Control System Interaction Issues: Two Case Studies  

E-Print Network [OSTI]

Direct Digital Control (DDC) allows HVAC equipment to be controlled at an upper level (supervisory control) through commands from a central system, or at a lower-level (local-loop control) by local controllers. The various levels of equipment...

Chen, Q.; Deng, S.; Toole, C.; Xu, C.

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

A PDI for your HVAC System  

Broader source: Energy.gov [DOE]

This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question "HVAC proper installation energy savings: over-promising or under-deliverying?"

42

Modeling and optimization of building HVAC systems.  

E-Print Network [OSTI]

??This thesis presents the development of hybrid modeling methodologies for HVAC component static/steady-state models and dynamic/transient models, and the development and implementation of a model-based… (more)

Jin, Guang Yu.

2012-01-01T23:59:59.000Z

43

Review of Residential Low-Load HVAC Systems  

SciTech Connect (OSTI)

In support of the U.S. Department of Energy’s (DOE’s) Building America Program, Pacific Northwest National Laboratory (PNNL) conducted an investigation to inventory commercially available HVAC technologies that are being installed in low-load homes. The first step in this investigation was to conduct a review of published literature to identify low-load HVAC technologies available in the United States and abroad, and document the findings of existing case studies that have evaluated the performance of the identified technologies. This report presents the findings of the literature review, identifies gaps in the literature or technical understanding that must be addressed before low-load HVAC technologies can be fully evaluated, and introduces PNNL’s planned research and analysis for this project to address identified gaps and potential future work on residential low-load HVAC systems.

Brown, Scott A.; Thornton, Brian; Widder, Sarah H.

2013-09-01T23:59:59.000Z

44

System-Level Monitoring and Diagnosis of Building HVAC System.  

E-Print Network [OSTI]

??Heating, ventilation, and air conditioning (HVAC) is an indoor environmental technology that is extensively instrumented for large-scale buildings. Among all subsystems of buildings, the HVAC… (more)

Wu, Siyu

2013-01-01T23:59:59.000Z

45

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage  

E-Print Network [OSTI]

Optimised Scheduling of a Solar-Assisted HVAC System withA. Mammoli. Modeling of a solar-assisted HVAC system withOPTIMISED SCHEDULING OF A SOLAR-ASSISTED HVAC SYSTEM WITH

Mammoli, Andrea

2014-01-01T23:59:59.000Z

46

Automatic Control Technology in the HVAC System  

Science Journals Connector (OSTI)

In the field of VAV air-conditioning system (Variable Air Volume, VAV) control theory and practical study, the paper analyzed the methods used by the China's VAV control procedures including Static Pressure Control, Variable Pressure Control and Total ...

Ren Tao; Gao Jingmin; Jia Wenwen

2009-01-01T23:59:59.000Z

47

Energy-Efficient Building HVAC Control Using Hybrid System LBMPC  

E-Print Network [OSTI]

Improving the energy-efficiency of heating, ventilation, and air-conditioning (HVAC) systems has the potential to realize large economic and societal benefits. This paper concerns the system identification of a hybrid system model of a building-wide HVAC system and its subsequent control using a hybrid system formulation of learning-based model predictive control (LBMPC). Here, the learning refers to model updates to the hybrid system model that incorporate the heating effects due to occupancy, solar effects, outside air temperature (OAT), and equipment, in addition to integrator dynamics inherently present in low-level control. Though we make significant modeling simplifications, our corresponding controller that uses this model is able to experimentally achieve a large reduction in energy usage without any degradations in occupant comfort. It is in this way that we justify the modeling simplifications that we have made. We conclude by presenting results from experiments on our building HVAC testbed, which s...

Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

2012-01-01T23:59:59.000Z

48

Building energy modeling programs comparison Research on HVAC systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

energy modeling programs comparison Research on HVAC systems energy modeling programs comparison Research on HVAC systems simulation part Title Building energy modeling programs comparison Research on HVAC systems simulation part Publication Type Journal Year of Publication 2013 Authors Zhou, Xin, Da Yan, Tianzhen Hong, and Dandan Zhu Keywords Building energy modeling programs, comparison tests, HVAC system simulation, theory analysis Abstract Building energy simulation programs are effective tools for the evaluation of building energy saving and optimization of design. The fact that large discrepancies exist in simulated results when different BEMPs are used to model the same building has caused wide concern. Urgent research is needed to identify the main elements that contribute towards the simulation results. This technical report summarizes methodologies, processes, and the main assumptions of three building energy modeling programs (BEMPs) for HVAC calculations: EnergyPlus, DeST, and DOE-2.1E, and test cases are designed to analyze the calculation process in detail. This will help users to get a better understanding of BEMPs and the research methodology of building simulation. This will also help build a foundation for building energy code development and energy labeling programs.

49

Airborne Particulate Matter in HVAC Systems and its Influence on Indoor Air Quality  

E-Print Network [OSTI]

This paper first reviews the mechanisms governing movement of PMs in HVAC systems. Then, the basic equations governing PM deposition in ducts are introduced and investigations on airborne PMs distribution in HVAC systems are reviewed. The influence...

Fu, Z.; Li, N.; Wang, H.

2006-01-01T23:59:59.000Z

50

Direct Digital Control- A Tool for Energy Management of HVAC Systems  

E-Print Network [OSTI]

Direct digital control (DDC) applied to heating, ventilating, and air-conditioning (HVAC) systems corrects many of the deficiencies of conventional automatic temperature control systems. By applying new control sequences, DDC optimizes HVAC energy...

Swanson, K.

51

Commissioning and Performance Diagnostics for HVAC Control Systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Commissioning and Performance Diagnostics for HVAC Control Systems Commissioning and Performance Diagnostics for HVAC Control Systems Speaker(s): Ashish Singhal Date: December 20, 2006 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Philip Haves The presentation will focus on practical aspects of commissioning control loops in commercial HVAC systems and evaluating their routine performance. Simple and theoretically sound methods for diagnosing control performance will be presented that detect serious performance issues associated with control loops in modern buildings. The discussion will center on a new control loop commissioning tool that helps field personnel to quickly test, tune and troubleshoot control loops. In addition to the active tests for commissioning control loops, a suite of diagnostic algorithms are used in a

52

Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond  

E-Print Network [OSTI]

Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond Lawrence Berkeley of the commissioning of HVAC systems. The approach is based on software that generates a sequence of test signals for new and retrofit projects. Introduction The performance of many HVAC systems is limited more by poor

Diamond, Richard

53

Co-simulation for performance prediction of integrated building and HVAC systems -An analysis of solution  

E-Print Network [OSTI]

Co-simulation for performance prediction of integrated building and HVAC systems - An analysis performance simulation of buildings and heating, ventilation and air- conditioning (HVAC) systems can help, heating, ventilation and air-conditioning (HVAC) systems are responsible for 10%-60% of the total building

54

BLACK-BOX MODELLING OF HVAC SYSTEM: IMPROVING THE PERFORMANCES OF NEURAL NETWORKS  

E-Print Network [OSTI]

BLACK-BOX MODELLING OF HVAC SYSTEM: IMPROVING THE PERFORMANCES OF NEURAL NETWORKS Eric FOCK Ile de La Réunion - FRANCE ABSTRACT This paper deals with neural networks modelling of HVAC systems of HVAC system can be modelled using manufacturer design data presented as derived performance maps

Boyer, Edmond

55

EVALUATION OF EMERGING DIAGNOSTIC TOOLS FOR COMMERCIAL HVAC SYSTEMS Hannah Friedman Mary Ann Piette  

E-Print Network [OSTI]

EVALUATION OF EMERGING DIAGNOSTIC TOOLS FOR COMMERCIAL HVAC SYSTEMS Hannah Friedman Mary Ann Piette for commercial HVAC systems. We present a brief description of the diagnostic tools, and then focus on evaluating, ventilating, and air-conditioning (HVAC) systems (Gregerson, 1997, Claridge et al., 2000). If these energy

56

Fuzzy Rule Reduction and Tuning of Fuzzy Logic Controllers for a HVAC System  

E-Print Network [OSTI]

Fuzzy Rule Reduction and Tuning of Fuzzy Logic Controllers for a HVAC System R. Alcal´a, J. Alcal, Ventilating and Air Conditioning (HVAC) Systems are equip- ments usually implemented for maintaining satisfactory comfort conditions in build- ings. The design of Fuzzy Logic Controllers (FLCs) for HVAC Systems

Granada, Universidad de

57

Tile of the document: HVAC system component-based modeling and implementation  

E-Print Network [OSTI]

1 Abstract Tile of the document: HVAC system component-based modeling and implementation Karam the foundation for modeling components that are used in HVAC systems (heating, ventilation, and air conditioning such functionalities. #12;2 HVAC system component-based modeling and implementation By Karam H. Rajab Scholarly

Austin, Mark

58

A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS  

E-Print Network [OSTI]

1 A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS T. I describes a control scheme with fault detection capabilities suitable for application to HVAC systems as a reference of correct operation. Faults that occur in the HVAC system under control cause the PI

59

Air filtration: Choosing the right filter class for HVAC systems  

Science Journals Connector (OSTI)

As anyone who works with air filtration knows, getting the best from a system is about more than choosing efficient media and correct installation. Thomas Carlson of Vokes Air explains the importance of using and selecting the right filter class for a typical HVAC system.

Thomas Carlson

2008-01-01T23:59:59.000Z

60

Conventional Facilities Chapter 6: HVAC Systems 6-1 NSLS-II Preliminary Design Report  

E-Print Network [OSTI]

Conventional Facilities Chapter 6: HVAC Systems 6-1 NSLS-II Preliminary Design Report 6 MECHANICAL ­ HVAC SYSTEMS 6.1 Design Criteria 6.1.1 Codes and Standards The latest edition of the codes, standards have adequate capacity and head, no chilled water pumps #12;Conventional Facilities Chapter 6: HVAC

Ohta, Shigemi

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

RF propagation in an HVAC duct system: impulse response characteristics of the channel  

E-Print Network [OSTI]

RF propagation in an HVAC duct system: impulse response characteristics of the channel Pavel V, the heating, ventilation, and air conditioning (HVAC) duct system in buildings is a complex network of hollow at RF and microwave frequencies of com- mon interest. HVAC ducts can be used as a wireless communication

Stancil, Daniel D.

62

RoomZoner: Occupancy-based Room-Level Zoning of a Centralized HVAC System  

E-Print Network [OSTI]

RoomZoner: Occupancy-based Room-Level Zoning of a Centralized HVAC System Tamim Sookoor & Kamin. In this paper we present a CPS that enables a centralized Heating, Ventila- tion, and Air Conditioning (HVAC application due to residential HVAC systems ac- counting for over 15% of all U.S. energy usage, making it one

Whitehouse, Kamin

63

Performance Validation and Energy Analysis of HVAC Systems using Simulation  

E-Print Network [OSTI]

that energy savings of between 15% and 40% could be made in commercial buildings by closer monitoring and supervision of energy-usage and related data. An earlier study by Kao and Pierce (1983) showed that sensor1 Performance Validation and Energy Analysis of HVAC Systems using Simulation Tim Salsbury and Rick

Diamond, Richard

64

Randomized Model Predictive Control for HVAC Systems Alessandra Parisio, Damiano Varagnolo, Daniel Risberg,  

E-Print Network [OSTI]

Randomized Model Predictive Control for HVAC Systems Alessandra Parisio, Damiano Varagnolo, Daniel Conditioning (HVAC) sys- tems play a fundamental role in maintaining acceptable ther- mal comfort and Indoor. A possible solu- tion is to develop effective control strategies for HVAC sys- tems, but this is complicated

Johansson, Karl Henrik

65

Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture  

E-Print Network [OSTI]

Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture Ariton E. Xhafa, Paisarn-- In this paper, we present an innovative solution to the handover problem in multi-story buildings using HVAC of the indoor wireless networks that use the heating, ventilation, and air conditioning (HVAC) ducts

Stancil, Daniel D.

66

Plutonium Finishing Plant (PFP) HVAC System Component Index  

SciTech Connect (OSTI)

This document lists safety class (SC) and safety significant (SS) components for the Heating Ventilation Air Conditioning (HVAC) and specifies the critical characteristics for Commercial Grade Items (CGI), as required by HNF-PRO-268 and HNF-PRO-18 19. These are the minimum specifications that the equipment must meet in order to properly perform its safety function. There may be several manufacturers or models that meet the critical characteristics for any one item. The Plutonium Finishing Plant (PFP) HVAC System includes sub-systems 25A through 25K. Specific system boundaries and justifications are contained in HNF-SD-CP-SDD-005, ''Definition and Means of Maintaining the Ventilation System Confinement Portion of the PFP Safety Envelope.'' The procurement requirements associated with the system necessitates procurement of some system equipment as Commercial Grade Items in accordance with HNF-PRO-268, ''Control of Purchased Items and Services.''

DIAZ, E.N.

2000-03-30T23:59:59.000Z

67

HVAC systems in the current stock of U. S. K-12 schools. Final report, May 91-Mar 92  

SciTech Connect (OSTI)

The report summarizes information on heating, ventilating, and air-conditioning (HVAC) systems commonly found in U.S. school buildings and the effect that operating these systems has on indoor radon levels. The report describes the ability of various HVAC systems to pressurize and ventilate classroom spaces, how they operate, and how they are controlled. Some information is given to compare systems from the standpoint of energy use, cost, and their ability to maintain stable levels of static pressure in classrooms and/or to adequately ventilate the spaces. There do not appear to be any well defined trends in types of HVAC systems involved in current school building construction and modification. Systems looked at include those using reheat and/or mixing, unit ventilators (UVs), and two-fan, dual-duct variable air volume (VAV) systems.

Parker, J.D.

1992-07-01T23:59:59.000Z

68

An Application of State-Of-The-Art HVAC and Building Systems  

E-Print Network [OSTI]

AN APPLICATION OF STATE-OF-THE-ART HVAC AND BUILDING SYSTEMS DONALD P. FIORINO, M.S., P.E. Energy Conservation Manager Texas Instruments, Inc. Defense Systems and Electronics Group Dallas, Texas ABSTRACT This case study describes... the successful application of state-of-the-art HVAC and building systems at a large commercial office and industrial facility. The facility's exterior envelope systems, HVAC systems, lighting systems, energy conservation systems, exhaust/heat recovery...

Fiorino, D. P.

69

Wireless Demand Response Controls for HVAC Systems  

E-Print Network [OSTI]

art VAV: variable-air-volume VFD: variable frequency drivespeed command to the variable frequency drive(s) (VFDs). The

Federspiel, Clifford

2010-01-01T23:59:59.000Z

70

Measuring rates of outdoor airflow into HVAC systems  

SciTech Connect (OSTI)

During the last few years, new technologies have been introduced for measuring the flow rates of outside air into HVAC systems. This document describes one particular technology for measuring these airflows, a system and a related protocol developed to evaluate this and similar measurement technologies under conditions without wind, and the results of our evaluations. We conclude that the measurement technology evaluated can provide a reasonably accurate measurement of OA flow rate over a broad range of flow, without significantly increasing airflow resistance.

Fisk, William J.; Faulkner, David; Sullivan, Douglas P.; Delp, Woody

2002-10-01T23:59:59.000Z

71

Outdoor airflow into HVAC systems: An evaluation of measurement  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Outdoor airflow into HVAC systems: An evaluation of measurement Outdoor airflow into HVAC systems: An evaluation of measurement technologies Title Outdoor airflow into HVAC systems: An evaluation of measurement technologies Publication Type Report LBNL Report Number LBNL-53834 Year of Publication 2003 Authors Fisk, William J., David Faulkner, Douglas P. Sullivan, and William W. Delp Abstract During the last few years, new technologies have been introduced for measuring the flow rates of outdoor air (OA) into HVAC systems; however, an evaluation of these measurement technologies has not previously been published. This document describes a test system and protocols developed for controlled evaluation of these measurement technologies. The results of tests of three measurement technologies are also summarized. The test system and protocol were judged practical and very useful. The test results indicate that one measurement technology can measure OA flow rates with errors of 20% or less without a field-based calibration, as long as the OA velocities are sufficient to provide an accurately measurable pressure signal. The test results for a second measurement technology are similar; however, a difficult field-based calibration relating the OA flow rate with the pressure signal would be required to reduce errors below approximately 30%. The errors in OA flow rates measured with the third measurement technology, that uses six electronic airspeed sensors downstream of the OA inlet louver, exceeded 100%; however, these errors could be substantially reduced through a difficult field based calibration. The effects of wind on the accuracy of these measurement technologies still needs to be evaluated

72

Wavelet based artificial neural network applied for energy efficiency enhancement of decoupled HVAC system  

Science Journals Connector (OSTI)

Control methodologies could lower energy demand and consumption of heating, ventilating and air conditioning (HVAC) systems and, simultaneously, achieve better comfort conditions. However, the application of classical controllers is unsatisfactory as HVAC systems are non-linear and the control variables such as temperature and relative humidity (RH) inside the thermal zone are coupled. The objective of this study is to develop and simulate a wavelet-based artificial neural network (WNN) for self tuning of a proportional-derivative (PD) controller for a decoupled bi-linear HVAC system with variable air volume and variable water flow responsible for controlling temperature and RH of a thermal zone, where thermal comfort and energy consumption of the system are evaluated. To achieve the objective, a WNN is used in series with an infinite impulse response (IIR) filter for faster and more accurate identification of system dynamics, as needed for on-line use and off-line batch mode training. The WNN-IIR algorithm is used for self-tuning of two PD controllers for temperature and RH. The simulation results show that the WNN-IIR controller performance is superior, as compared with classical PD controller. The enhancement in efficiency of the HVAC system is accomplished due to substantially lower consumption of energy during the transient operation, when the gain coefficients of PD controllers are tuned in an adaptive manner, as the steady state setpoints for temperature and RH are better reached in a shorter period of time. The multi-zone analyses are suggested for future work.

G. Jahedi; M.M. Ardehali

2012-01-01T23:59:59.000Z

73

Total Quality Commissioning for HVAC Systems to Assure High Performance Throughout the Whole Life Cycle  

E-Print Network [OSTI]

TOTAL QUALITY COMMISSIONING FOR HVAC SYSTEMS TO ASSURE HIGH PERFORMANCE THROUGHOUT THE WHOLE LIFE CYCLE By: Grahame E. Maisey, P.E., and Beverly Milestone, LEED AP Building Services Consultants INTRODUCTION Current HVAC systems... are not coming close to approaching life cycle performance expectations for energy, operation and maintenance, occupant comfort and productivity and longevity. HVAC systems in buildings claiming to be sustainable, with integrated, energy conscious design...

Maisey, G.; Milestone, B.

2005-01-01T23:59:59.000Z

74

REDESIGN OF HVAC SYSTEM TO IMPROVE ENERGY EFFICIENCY OF EDUCATIONAL BUILDING.  

E-Print Network [OSTI]

??An energy modeling software was used to analyze the current building configuration and simulations were performed in an attempt to redesign the current HVAC system… (more)

Hagene, Brian Matthew

2012-01-01T23:59:59.000Z

75

Energy Consumption Analyses of Frequently-used HVAC System Types in High Performance Office Buildings.  

E-Print Network [OSTI]

??The high energy consumption of heating, ventilation and air-conditioning (HVAC) systems in commercial buildings is a hot topic. Office buildings, a typical building set of… (more)

Yan, Liusheng

2014-01-01T23:59:59.000Z

76

Co-design of control algorithm and embedded platform for building HVAC systems  

Science Journals Connector (OSTI)

The design of heating, ventilation and air conditioning (HVAC) systems is crucial for reducing energy consumption in buildings. As complex cyber-physical systems, HVAC systems involve three closely-related subsystems -- the control algorithm, the physical ... Keywords: building energy efficiency, co-design, platform-based design

Mehdi Maasoumy; Qi Zhu; Cheng Li; Forrest Meggers; Alberto Sangiovanni-Vincentelli

2013-04-01T23:59:59.000Z

77

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage  

E-Print Network [OSTI]

of a solar-thermal- assisted hvac system. Energy andsolar thermal collectors using flat reflective surfaces. Solar Energy,of a solar-assisted HVAC system with thermal storage. Energy

Mammoli, Andrea

2014-01-01T23:59:59.000Z

78

Thermal Storage Options for HVAC Systems  

E-Print Network [OSTI]

this method is based on the specific heat of water rather than the latent 'heat of fusion of ice as in ice storage, it requires about 4 times the storage capacity of an equivalent ice storage system. ? Salt Storage: This system utilizes eutectic salts... which freeze and melt around 47 o F. Exist ing chillers can be easily retrofitted for salt storage or chilled water storage. For ice stor age systems, a direct refrigerant system or glycol chillers are suitable. This paper discusses the details...

Weston, R. F.; Gidwani, B. N.

79

An experimental system for advanced heating, ventilating and air conditioning (HVAC) control  

Science Journals Connector (OSTI)

While having the potential to significantly improve heating, ventilating and air conditioning (HVAC) system performance, advanced (e.g., optimal, robust and various forms of adaptive) controllers have yet to be incorporated into commercial systems. Controllers consisting of distributed proportional-integral (PI) control loops continue to dominate commercial HVAC systems. Investigation into advanced HVAC controllers has largely been limited to proposals and simulations, with few controllers being tested on physical systems. While simulation can be insightful, the only true means for verifying the performance provided by HVAC controllers is by actually using them to control an HVAC system. The construction and modeling of an experimental system for testing advanced HVAC controllers, is the focus of this article. A simple HVAC system, intended for controlling the temperature and flow rate of the discharge air, was built using standard components. While only a portion of an overall HVAC system, it is representative of a typical hot water to air heating system. In this article, a single integrated environment is created that is used for data acquisition, controller design, simulation, and closed loop controller implementation and testing. This environment provides the power and flexibility needed for rapid prototyping of various controllers and control design methodologies.

Michael Anderson; Michael Buehner; Peter Young; Douglas Hittle; Charles Anderson; Jilin Tu; David Hodgson

2007-01-01T23:59:59.000Z

80

Reliability and Functional Availability of HVAC Systems  

E-Print Network [OSTI]

This paper presents a model to calculate the reliability and availability of heating, ventilation and air conditioning systems. The reliability is expressed in the terms of reliability, maintainability and decision capability. These terms are a...

Myrefelt, S.

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Electric, Gas, and Electric/Gas Energy Options for Cold-Air HVAC Systems  

E-Print Network [OSTI]

An important aspect of the design of cost-effective HVAC systems today is (a) sensitivity to the cost impact of the interplay of utility demand charges, time-of-day rates, gas rates, and gas/electric utility incentive programs vis-à-vis HVAC system...

Meckler, G.

1989-01-01T23:59:59.000Z

82

Proposal for the Award of a Contract for Maintenance, Operation and Minor Installation Work for CERN Cooling and HVAC Systems  

E-Print Network [OSTI]

Proposal for the Award of a Contract for Maintenance, Operation and Minor Installation Work for CERN Cooling and HVAC Systems

1996-01-01T23:59:59.000Z

83

Case study field evaluation of a systems approach to retrofitting a residential HVAC system  

SciTech Connect (OSTI)

This case study focusing on a residence in northern California was undertaken as a demonstration of the potential of a systems approach to HVAC retrofits. The systems approach means that other retrofits that can affect the HVAC system are also considered. For example, added building envelope insulation reduces building loads so that smaller capacity HVAC system can be used. Secondly, we wanted to examine the practical issues and interactions with contractors and code officials required to accomplish the systems approach because it represents a departure from current practice. We identified problems in the processes of communication and installation of the retrofit that led to compromises in the final energy efficiency of the HVAC system. These issues must be overcome in order for HVAC retrofits to deliver the increased performance that they promise. The experience gained in this case study was used to optimize best practices guidelines for contractors (Walker 2003) that include building diagnostics and checklists as tools to assist in ensuring the energy efficiency of ''house as a system'' HVAC retrofits. The best practices guidelines proved to be an excellent tool for evaluating the eight existing homes in this study, and we received positive feedback from many potential users who reviewed and used them. In addition, we were able to substantially improve the energy efficiency of the retrofitted case study house by adding envelope insulation, a more efficient furnace and air conditioner, an economizer and by reducing duct leakage.

Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

2003-09-01T23:59:59.000Z

84

Energy Conservation Studies of Existing HVAC Systems  

E-Print Network [OSTI]

start and stop of air handling unit~ consists of controlling uni t operation based on the time of day and day of the week. This can be accomplished by time clock control at the air ' handler or central control from an automatic I system. This scheme... start and stop of air handling unit~ consists of controlling uni t operation based on the time of day and day of the week. This can be accomplished by time clock control at the air ' handler or central control from an automatic I system. This scheme...

Patterson, C. L.; Phelan, T. R.

85

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage  

E-Print Network [OSTI]

solar energy available would result in overcharging of the hot storage.of a solar-assisted HVAC system with thermal storage. Energystorage and solar- assisted HVAC for the purpose of optimizing its energy

Mammoli, Andrea

2014-01-01T23:59:59.000Z

86

Procedures to identify Energy Conservation Opportunities applied to HVAC system: example of VSD of chilled water pumps  

E-Print Network [OSTI]

Procedures to identify Energy Conservation Opportunities applied to HVAC system: example of VSD of HVAC equipment using variable speed drive (VSD) is an Energy Conservation Opportunity (ECO) which can

Paris-Sud XI, Université de

87

Energy Savings with Energy-Efficient HVAC Systems in Commercial Buildings of Hong Kong  

E-Print Network [OSTI]

of the electricity in Hong Kong is consumed by commercial buildings, and heating, ventilation and air-conditioning (HVAC) is the largest end-user in such buildings, improving the efficiency of HVAC systems in commercial buildings, is the key measure to take in Hong...

Yang, J.; Chan, K.; Wu, X.

2006-01-01T23:59:59.000Z

88

Feasibility of Retrofitting Centralized HVAC Systems for Room-Level Zoning Tamim Sookoor, Brian Holben, Kamin Whitehouse  

E-Print Network [OSTI]

Feasibility of Retrofitting Centralized HVAC Systems for Room-Level Zoning Tamim Sookoor, Brian {sookoor,bnh4k,whitehouse}@cs.virginia.edu Abstract--Heating, ventilation, and cooling (HVAC) accounts's largest energy consumers. Many attempts have been made to optimize the control of HVAC systems

Whitehouse, Kamin

89

Fabrication of A Quantum Well Based System for Truck HVAC  

Broader source: Energy.gov [DOE]

Discusses performance differences between conventional modules and quantum well modules and details a conventional HZ-14 device, using bulk bismuth-telluride advantageous for truck HVAC applications.

90

Comparison of Building Energy Modeling Programs: HVAC Systems  

E-Print Network [OSTI]

or FAU with no control), supply water temperature, pressureunder the same control The supply air temperature and supplyHVAC control strategies of supply air temperature, supply

Zhou, Xin

2014-01-01T23:59:59.000Z

91

Minimization of energy consumption in HVAC systems with data-driven models and an interior-point method  

E-Print Network [OSTI]

Minimization of energy consumption in HVAC systems with data-driven models and an interior online 13 June 2014 Keywords: HVAC Interior-point method Internal heat gain Multilayer perceptron-driven approach is applied to minimize energy consumption of a heating, ventilating, and air conditioning (HVAC

Kusiak, Andrew

92

Requirements for Commissioning HVAC Systems Using BEMS and Commissioning the BEMS Itself Based on Questionnaire Surveys  

E-Print Network [OSTI]

In this paper the present status and requirements for commissioning of HVAC Systems using Building Energy Management Systems (BEMS) and commissioning the BEMS itself are investigated and summarized. The information presented is based on the results...

Yoshida, H.; Vaezi-Nejad, H.; Choiniere, D.; Wang, F.

2004-01-01T23:59:59.000Z

93

A Qualitive Modeling Approach for Fault Detection and Diagnosis on HVAC Systems  

E-Print Network [OSTI]

This paper describes the basics and first test results of a model based approach using qualitative modeling to perform Fault Detection and Diagnostics (FDD) on HVAC and R systems. A quantized system describing the qualitative behavior of a...

Muller, T.; Rehault, N.; Rist, T.

2013-01-01T23:59:59.000Z

94

PV modules, with a life measured in decades, will typically be in place longer than the outdoor unit of a HVAC system.  

E-Print Network [OSTI]

unit of a HVAC system. When the performance of an HVAC system deteriorates, it is usually inspected remain installed on the roof even after the system is no longer being used. Although HVAC units have only jumpers and screws effectively bond all parts of the listed device together. HVAC components are typically

Johnson, Eric E.

95

HVAC Market Study:  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

HVAC Market Study: Understanding how energy efficient products get to market Fall 2014 through Winter 2015 Research Manager: Carrie Cobb, clcobb@bpa.gov, 503-230-4985 HVAC systems...

96

A Unified and Integrated Energy Management System for HVAC Spaces and Power House  

E-Print Network [OSTI]

A UNIFIED AND INTEGRATED ENERGY MANAGEMENT SYSTEM FOR HVAC SPACES AND POWER HOUSE A.Kaya The University of Akron Mechanical Engineering Akron,OH 44325 ABSTRACT This paper describes a totally integrated energy management system throughout... the plant and facilities. The equipment involves: the power flant (boilers, cogeneration turbines, chillers); HVAC 0 buildings; air handling and other distribution systems. The energy management system has the architecture for data transmission...

Kaya, A.; Debban, G. D.

97

Air-Side Energy Use Calculations for Four HVAC Systems: Dual Duct Constant Volume (DDCAV), Dual Duct Variable Volume (DDVAV), Constant Volume with Reheat (CAVRH), Variable Volume with Reheat (VAVRH), Four Pipe Fan Coil Unit (FC), Four Pipe Induction Unit (FI), and Single Zone (SZ) Systems, Revised June 2002  

E-Print Network [OSTI]

(CAVRH), and variable volume with reheat (VAVRH), four pipe fan coil unit (FC), four pipe induction unit (FI), and a single zone air conditioning system (SZ). These calculations are presented in spreadsheets that include a running commentary so...

Haberl, J. S.; Bou-Saada, T. E.; Saman, N. F.

2001-01-01T23:59:59.000Z

98

CALIFORNIA ENERGY Large HVAC Building  

E-Print Network [OSTI]

CALIFORNIA ENERGY COMMISSION Large HVAC Building Survey Information Database of Buildings over 100 Design of Large Commercial HVAC Systems research project, one of six research elements in the Integrated Design of Large Commercial HVAC Systems Integrated Design of Small Commercial HVAC Systems Integrated

99

Total and Peak Energy Consumption Minimization of Building HVAC Systems Using Model Predictive Control  

E-Print Network [OSTI]

inputs. The idea of modeling building thermal behavior usingThe detail of building thermal modeling is pre- sented in [Modeling and optimal control algorithm design for hvac systems in energy efficient buildings,’’

Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2012-01-01T23:59:59.000Z

100

HVAC system optimization with CO2 concentration control using genetic algorithms  

Science Journals Connector (OSTI)

This study describes the use of genetic algorithms (GAs) for operating standard HVAC systems (HVAC—heating, ventilation and air conditioning) in order to optimize performance, primarily with regard to power saving. Genetic algorithms were introduced as an instrument for solving optimization problems. Analytic optimization procedures are widely used in other fields of engineering, but they are difficult to operate within HVAC systems, because the range of the research is usually too broad, the problems are not linear but rather discontinuous, and they mostly have complex limitations. This is why for this type of system genetic algorithms are used, since they have the qualities of robustness and efficiency that are crucial for finding the optimal solution. A simulation is conducted in order to demonstrate how much power can be saved by using the suggested method of CO2 concentration control in a standard HVAC system. In addition to Matlab Simulink, the suggested method is verified with Energy software.

Velimir Congradac; Filip Kulic

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

CO 2 - Based Demand-Controlled Ventilation Control Strategies for Multi-Zone HVAC Systems  

E-Print Network [OSTI]

CO 2-based demand-controlled ventilation DCV strategy offers a great opportunity to reduce energy consumption in HVAC systems while providing the required ventilation. However, implementing CO 2-based DCV under ASHRAE 62.1.2004 through 2010...

Nassif, N.

2011-01-01T23:59:59.000Z

102

Analysis of the HVAC System at the Willow Branch Intermediate School  

E-Print Network [OSTI]

This report presents an analysis of the HVAC system at the Willow Branch Intermediate School for the MEEN 685 class project. The school is located at College Station, Texas. A portion of the school belonged to Oakwood Intermediate School which...

Wei, G.

1997-01-01T23:59:59.000Z

103

Computational Study on Thermal Properties of HVAC System with Building Structure Thermal Storage  

E-Print Network [OSTI]

Building structure thermal storage (BSTS) HVAC systems can store heat during nighttime thermal storage operation (nighttime operation hours) by using off-peak electricity and release it in the daytime air-conditioning operation (daytime operation...

Sato, Y.; Sagara, N.; Ryu, Y.; Maehara, K.; Nagai, T.

2007-01-01T23:59:59.000Z

104

Development of HVAC System Performance Criteria Using Factorial Design and DOE-2 Simulation  

E-Print Network [OSTI]

A new approach is described for the development of Heating, Ventilating, and Air-conditioning (HVAC) System Performance Criteria for the Texas Building Energy Design Standard. This approach integrates a design of experimental methodology and DOE-2...

Hou, D.; Jones, J. W.; Hunn, B. D.; Banks, J. A.

1996-01-01T23:59:59.000Z

105

Fight Fall Allergies and Save Energy by Checking Your HVAC System |  

Broader source: Energy.gov (indexed) [DOE]

Fight Fall Allergies and Save Energy by Checking Your HVAC System Fight Fall Allergies and Save Energy by Checking Your HVAC System Fight Fall Allergies and Save Energy by Checking Your HVAC System October 15, 2012 - 3:19pm Addthis Change your furnace filter to help keep allergies at bay and keep your furnace and air conditioner running efficiently. | Photo courtesy of ©iStockphoto.com/JaniceRichard. Change your furnace filter to help keep allergies at bay and keep your furnace and air conditioner running efficiently. | Photo courtesy of ©iStockphoto.com/JaniceRichard. Elizabeth Spencer Communicator, National Renewable Energy Laboratory What does this mean for me? Change your furnace filters every month or two to keep your HVAC equipment operating efficiently. I have unbelievably horrible fall allergies. I've never figured out what

106

Outdoor airflow into HVAC systems: An evaluation of measurement technologies  

SciTech Connect (OSTI)

During the last few years, new technologies have been introduced for measuring the flow rates of outdoor air (OA) into HVAC systems; however, an evaluation of these measurement technologies has not previously been published. This document describes a test system and protocols developed for controlled evaluation of these measurement technologies. The results of tests of three measurement technologies are also summarized. The test system and protocol were judged practical and very useful. The test results indicate that one measurement technology can measure OA flow rates with errors of 20% or less without a field-based calibration, as long as the OA velocities are sufficient to provide an accurately measurable pressure signal. The test results for a second measurement technology are similar; however, a difficult field-based calibration relating the OA flow rate with the pressure signal would be required to reduce errors below approximately 30%. The errors in OA flow rates measured with the third measurement technology, that uses six electronic airspeed sensors downstream of the OA inlet louver, exceeded 100%; however, these errors could be substantially reduced through a difficult field based calibration. The effects of wind on the accuracy of these measurement technologies still needs to be evaluated.

Fisk, William J.; Faulkner, David; Sullivan, Douglas P.; Delp, Woody

2003-09-01T23:59:59.000Z

107

HVAC Installed Performance  

Broader source: Energy.gov (indexed) [DOE]

HVAC Installed Performance HVAC Installed Performance ESI, Tim Hanes Context * The building envelope has historically been the focus in residential homes. * The largest consumer of energy in residential homes is typically the HVAC system. * Testing the performance of the HVAC system has not been pursued to its full potential. Technical Approach * Currently very little performance testing is being done to the HVAC system. * The only way to know if a HVAC system is operating correctly is to measure the Btu/h. * This should be done at the equipment and at the the system. Recommended Guidance * Training of HVAC technicians, installers, and salespeople is a must. * If only the technician is trained than implementing the change will not happen. * Public awareness of proper installation and its

108

Improving the Efficiency of Light-Duty Vehicle HVAC Systems using Zonal Thermoelectric Devices and Comfort Modeling  

Broader source: Energy.gov [DOE]

Summarizes results from a study to identify and demonstrate technical and commercial approaches necessary to accelerate the deployment of zonal TE HVAC systems in light-duty vehicles

109

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage  

E-Print Network [OSTI]

1980, but its thermal solar and storage systems received achiller. A 30 m heat storage tank solar decouples heatfacility with thermal storage and solar- assisted HVAC for

Mammoli, Andrea

2014-01-01T23:59:59.000Z

110

CALIFORNIA ENERGY Large HVAC Energy Impact Report  

E-Print Network [OSTI]

CALIFORNIA ENERGY COMMISSION Large HVAC Energy Impact Report Statewide Energy Impact Report are part of the Integrated Design of Large Commercial HVAC Systems research project. The reports: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

111

Survival of bioaerosols in HVAC system photocatalytic filters  

Science Journals Connector (OSTI)

Abstract The survival of an experimental bioaerosol in photocatalytic and non-photocatalytic filters was investigated under UV-A or UV-C radiation exposure. To ensure the generation of reproducible bioaerosols in real operating conditions of Heating, Ventilation and Air Conditioning (HVAC) systems and their homogeneous coating on filters, a reactor with an optimal geometry was developed. The bacterial aerosol was generated from standardised bacterial suspensions and the Gram-negative bacterial model Escherichia coli was used as the experimental organism. The bioaerosol was characterised in terms of particle size distribution, reproducibility and stability over time. The coating of aerosolised cells on the filters was then studied. The total number of aerosolised E. coli cells was different from the amount of cultivable bacterial cells extracted from filters, probably resulting from the stress of the aerosolisation process. Damages to the outer membrane of E. coli cells were clearly observed through SEM and epifluorescent microscopy analysis. The influence of important physical parameters in the reactor-aerosolisation duration, frontal velocity and relative humidity- on the amount of aerosolised cells coated on filters were also investigated. Finally, the effects of UV-A or UV-C radiation were assessed on aerosolised microorganisms coated on HEPA photocatalytic filters and on photocatalytic or non-photocatalytic filters containing activated charcoal. The HEPA photocatalytic filters demonstrated a better disinfection efficiency with full damages of the aerosolised bacterial cells, probably resulting from an optimal contact between TiO2 coating and the microorganisms. In contrast, the use of filters with activated charcoal resulted in the apparition of an inactivation threshold that could be attributed to the penetration of aerosolised cells within the activated charcoal layer and the absence of contact with the photocatalyst. However, UV-C photocatalysis was able to inactivate faster and, at the same time, mineralise biological pollutants than UV-A.

S. Pigeot-Remy; J.C. Lazzaroni; F. Simonet; P. Petinga; C. Vallet; P. Petit; P.J. Vialle; C. Guillard

2014-01-01T23:59:59.000Z

112

Multi-objective optimization of HVAC system with an evolutionary computation algorithm  

Science Journals Connector (OSTI)

A data-mining approach for the optimization of a HVAC (heating, ventilation, and air conditioning) system is presented. A predictive model of the HVAC system is derived by data-mining algorithms, using a dataset collected from an experiment conducted at a research facility. To minimize the energy while maintaining the corresponding IAQ (indoor air quality) within a user-defined range, a multi-objective optimization model is developed. The solutions of this model are set points of the control system derived with an evolutionary computation algorithm. The controllable input variables — supply air temperature and supply air duct static pressure set points — are generated to reduce the energy use. The results produced by the evolutionary computation algorithm show that the control strategy saves energy by optimizing operations of an HVAC system.

Andrew Kusiak; Fan Tang; Guanglin Xu

2011-01-01T23:59:59.000Z

113

Cooperative Control of Air Flow for HVAC Systems Shuai Liu1,2, Yushen Long1, Lihua Xie1 and Alexandre M. Bayen3  

E-Print Network [OSTI]

Cooperative Control of Air Flow for HVAC Systems Shuai Liu1,2, Yushen Long1, Lihua Xie1 for building heating, ven- tilation and air-conditioning (HVAC) systems. The strategy consists in two level and the HVAC system parameters. I. INTRODUCTION In recent years, energy saving and environment protection have

114

Residential commissioning to assess envelope and HVAC system performance  

SciTech Connect (OSTI)

Houses do not perform optimally or even as many codes and forecasts predict. For example, Walker et al. (1998a) found large variations in thermal distribution system efficiency, as much as a factor of two even between side-by-side houses with the same system design and installation crew. This and other studies (e.g., Jump et al. 1996) indicate that duct leakage testing and sealing can readily achieve a 25 to 30% reduction in installed cooling capacity and energy consumption. As another example, consider that the building industry has recognized for at least 20 years the substantial impact that envelope airtightness has on thermal loads, energy use, comfort, and indoor air quality. However, Walker et al. (1998a) found 50% variances in airtightness for houses with the same design and construction crews, within the same subdivision. A substantial reason for these problems is that few houses are now built or retrofitted using formal design procedures, most are field assembled from a large number of components, and there is no consistent process to identify problems or to correct them. Solving the problems requires field performance evaluations of houses using appropriate and agreed upon procedures. Many procedural elements already exist in a fragmented environment; some are ready now to be integrated into a new process called residential commissioning (Wray et al. 2000). For example, California's Title 24 energy code already provides some commissioning elements for evaluating the energy performance of new houses. A house consists of components and systems that need to be commissioned, such as building envelopes, air distribution systems, cooling equipment, heat pumps, combustion appliances, controls, and other electrical appliances. For simplicity and practicality, these components and systems are usually evaluated individually, but we need to bear in mind that many of them interact. Therefore, commissioning must not only identify the energy and non-energy benefits associated with improving the performance of a component, it must also indicate how individual components interact in the complete building system. For this paper, we limit our discussion to diagnostics in areas of particular concern with significant interactions: envelope and HVAC systems. These areas include insulation quality, windows, airtightness, envelope moisture, fan and duct system airflows, duct leakage, cooling equipment charge, and combustion appliance backdrafting with spillage. The remainder of this paper first describes what residential commissioning is, its characteristic elements, and how one might structure its process. Subsequent sections describe a consolidated set of practical diagnostics that the building industry can use now. Where possible, we also discuss the accuracy and usability of these diagnostics, based on recent laboratory work and field studies. We conclude by describing areas in need of research and development, such as practical field diagnostics for envelope thermal conductance and combustion safety. There are several potential benefits for builders, consumers, code officials, utilities, and energy planners of commissioning houses using a consistent set of validated methods. Builders and/or commissioning agents will be able to optimize system performance and reduce consumer costs associated with building energy use. Consumers will be more likely to get what they paid for and builders can show they delivered what was expected. Code officials will be better able to enforce existing and future energy codes. As energy reduction measures are more effectively incorporated into the housing stock, utilities and energy planners will benefit through greater confidence in predicting demand and greater assurance that demand reductions will actually occur. Performance improvements will also reduce emissions from electricity generating plants and residential combustion equipment. Research to characterize these benefits is underway.

Wray, Craig P.; Sherman, Max H.

2001-08-31T23:59:59.000Z

115

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Massieh Najafi1  

E-Print Network [OSTI]

of the building's air conditioning units from reaching occupied spaces, so this unit's energy is simply wastedModeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Massieh Najafi1 , David, Lawrence Berkeley National Laboratory, mdsohn@lbl.gov ABSTRACT Many studies have shown that energy savings

116

This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)  

E-Print Network [OSTI]

at Oklahoma State University (www.hvac.okstate.edu) The correct citation for the paper is: Rees, S.J., J cooling loads is of critical concern to designers of HVAC systems. The work reported here has been carried of the HVAC industry worldwide would be improved if common methods of performing key design calculations were

Ghajar, Afshin J.

117

A Simple Path Loss Prediction Model for HVAC Systems O. K. Tonguz, D. D. Stancil, A. E. Xhafa, A. G. Cepni, P. V. Nikitin  

E-Print Network [OSTI]

1 A Simple Path Loss Prediction Model for HVAC Systems O. K. Tonguz, D. D. Stancil, A. E. Xhafa, A, and air conditioning (HVAC) cylindrical ducts in 2.4-2.5 GHz frequency band. The model we propose predicts the average power loss between a transmitter-receiver pair in an HVAC duct network. This prediction model

Stancil, Daniel D.

118

Detection and diagnosis of faults and energy monitoring of HVAC systems with least-intrusive power analysis  

E-Print Network [OSTI]

Faults indicate degradation or sudden failure of equipment in a system. Widely existing in heating, ventilating, and air conditioning (HVAC) systems, faults always lead to inefficient energy consumption, undesirable indoor ...

Luo, Dong, 1966-

2001-01-01T23:59:59.000Z

119

Energy Master Plans for Sustainable, High Performance HVAC and Associated Systems for Hot and Humid Climates  

E-Print Network [OSTI]

; Equal pressure ducting systems; Modular heating and cooling generation, small zone control. 4.Complexity: If you cannot understand the system without explanation, it is too complex. If you need to read a sequence of operation more than once... by over 75%. It is the HVAC system selection and in particular the distribution systems that require to be carefully selected and designed to achieve long-term minimum electrical use. Electrical refrigeration uses only 25% of the electricity...

Maisey, G. E.; Milestone, B.

2004-01-01T23:59:59.000Z

120

VOLUME 11, NUMBER 2 HVAC&R RESEARCH APRIL 2005 An Optimization-Based Approach for  

E-Print Network [OSTI]

of energy consumption, and human comfort requirements. This paper presents a daily energy management in view of rising energy costs, the government mandate on reduction of energy consumption (Capehart et al requirements. A major portion of energy consumption of a building comes from HVAC units. For example

Luh, Peter

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM  

SciTech Connect (OSTI)

In this paper, a hotel with hybrid geothermal heat pump system (HyGSHP) in the Pensacola is selected and simulated by the transient simulation software package TRNSYS [1]. To verify the simulation results, the validations are conducted by using the monthly average entering water temperature, monthly facility consumption data, and etc. And three types of HVAC systems are compared based on the same building model and HVAC system capacity. The results are presented to show the advantages and disadvantages of HyGSHP compared with the other two systems in terms of energy consumptions, life cycle cost analysis.

Jiang Zhu; Yong X. Tao

2011-11-01T23:59:59.000Z

122

Integrated Ice Storage/Sprinkler HVAC System Sharply Cuts Energy Costs and Air-Distribution First Costs  

E-Print Network [OSTI]

Integrated ice thermal storage/sprinkler HVAC systems developed and applied by the author in several commercial applications shift a major portion of electric utility demand to cheaper off-peak hours, while also reducing significantly the first cost...

Meckler, G.

1986-01-01T23:59:59.000Z

123

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage  

E-Print Network [OSTI]

performance of a solar-thermal- assisted hvac system. Energyfor rows of fixed solar thermal collectors using flatassisted by a 232 m solar thermal array providing heat to a

Mammoli, Andrea

2014-01-01T23:59:59.000Z

124

Proceedings of Healthy Buildings 2009 Paper 680 Do forced air HVAC systems have a role in healthy homes?  

E-Print Network [OSTI]

Proceedings of Healthy Buildings 2009 Paper 680 Do forced air HVAC systems have a role in healthy-extreme weather conditions. #12;Proceedings of Healthy Buildings 2009 Paper 680 Thus, a central forced air

Siegel, Jeffrey

125

Post-Retrocommissioning HVAC Operations Monitoring Using Enterprise-Wide energy Management System  

E-Print Network [OSTI]

Post-retrocommissioning HVAC Operations Monitoring Using Enterprise-wide Energy Management System Narendra Amarnani Project Manager Brian Roberts Section Manager County of Los Angeles – ISD Los Angeles, California, USA Howard Choy... earned a graduate degree from Cal Poly University, Pomona. He is a Certified Energy Manager, a LEED® AP, and a Certified Energy Plan Examiner. Brian’s is the Section Manager of the Systems Section within Energy Management Division. His...

Amarnani, N.; Roberts, B.; Choy, H.

2007-01-01T23:59:59.000Z

126

Comparative guide to emerging diagnostic tools for large commercial HVAC systems  

SciTech Connect (OSTI)

This guide compares emerging diagnostic software tools that aid detection and diagnosis of operational problems for large HVAC systems. We have evaluated six tools for use with energy management control system (EMCS) or other monitoring data. The diagnostic tools summarize relevant performance metrics, display plots for manual analysis, and perform automated diagnostic procedures. Our comparative analysis presents nine summary tables with supporting explanatory text and includes sample diagnostic screens for each tool.

Friedman, Hannah; Piette, Mary Ann

2001-05-01T23:59:59.000Z

127

Definition: HVAC | Open Energy Information  

Open Energy Info (EERE)

HVAC HVAC Jump to: navigation, search Dictionary.png HVAC An abbreviation for the heating, ventilation, and air-conditioning system; the system or systems that condition air in a building.[1] View on Wikipedia Wikipedia Definition HVAC is the technology of indoor and vehicular environmental comfort. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. Refrigeration is sometimes added to the field's abbreviation as HVAC&R or HVACR, or ventilating is dropped as in HACR (such as the designation of HACR-rated circuit breakers). HVAC is important in the design of medium to large industrial and office buildings such as skyscrapers and in marine environments such as aquariums, where safe and

128

A new modelling methodology to control HVAC systems  

Science Journals Connector (OSTI)

Thermal comfort plays an important role in any working environment, but it is a very vague term and it is also very difficult to represent it on modern computers. Its proper definition could be a condition of the mind which expresses satisfaction with the thermal environment and, therefore, it depends on the individual’s physiology and psychology. Several researchers have investigated the relationships between room conditions and thermal comfort. Generally speaking, statistical approaches had been used whereas fuzzy and neural approaches have been recently proposed. In this work it is proposed a new thermal comfort model based on the P.O. Fanger PMV index according to the Institute of the University of Kansas and it has been adapted to a specific indoor ambience with a thermal comfort logger. The results showed that this methodology puts forward an adequate accuracy and suggests temperatures according to the present HVAC standards and those adaptive models show adequate values for thermal neutralities even though they are not suitable for energy saving due to its static value on a daily basis.

José A. Orosa

2011-01-01T23:59:59.000Z

129

Discussion of an Optimization Scheme for the Ground Source Heat Pump System of HVAC  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Renewable Energy Resources and a Greener Future Vol.VIII-13-3 Discussion of an Optimization Scheme for the Ground Source Heat Pump System of HVAC Wei Mu Suilin Wang Shuyuan Pan Yongzheng Shi Master Student... the Jurisdiction of Beijing Municipality (BJE10016200511). REFERENCES [1]Rongguang Wang,Yufeng Zhang,Yang,Xiaotong Zheng. Study on Direct Use Of Geothermal Energy For Heating And Its Energy Efficency Effects [J]. ACTA ENERGIAE SOLARIS SINICA, 2002, 23...

Mu, W.; Wang, S.; Pan, S.; Shi, Y.

2006-01-01T23:59:59.000Z

130

Energy saving by integrated control of natural ventilation and HVAC systems using model guide for comparison  

Science Journals Connector (OSTI)

Abstract Integrated control by controlling both natural ventilation and HVAC systems based on human thermal comfort requirement can result in significant energy savings. The concept of this paper differs from conventional methods of energy saving in HVAC systems by integrating the control of both these HVAC systems and the available natural ventilation that is based on the temperature difference between the indoor and the outdoor air. This difference affects the rate of change of indoor air enthalpy or indoor air potential energy storage. However, this is not efficient enough as there are other factors affecting the rate of change of indoor air enthalpy that should be considered to achieve maximum energy saving. One way of improvement can be through the use of model guide for comparison (MGFC) that uses physical-empirical hybrid modelling to predict the rate of change of indoor air potential energy storage considering building fabric and its fixture. Three methods (normal, conventional and proposed) are tested on an identical residential building model using predicted mean vote (PMV) sensor as a criterion test for thermal comfort standard. The results indicate that the proposed method achieved significant energy savings compared with the other methods while still achieving thermal comfort.

Raad Z. Homod; Khairul Salleh Mohamed Sahari; Haider A.F. Almurib

2014-01-01T23:59:59.000Z

131

Project examples Install new HVAC, electrical, fire protection,  

E-Print Network [OSTI]

Project examples Install new HVAC, electrical, fire protection, and plumbing systems in Mechanical. · Totransformthisspaceandincreaseaccessibility, anelevatorisrequired.Currently,Blakelydoesnot haveone. Replace HVAC and electrical system

Blanchette, Robert A.

132

Development of an energy evaluation methodology to make multiple predictions of the HVAC&R system energy demand for office buildings  

Science Journals Connector (OSTI)

Abstract HVAC&R systems are the most energy consuming building services, representing approximately half of the final energy use in the building sector. Despite their significant energy use, there is a lack of a consistent and homogeneous framework to efficiently guide research, mainly due to the complexity and variety of HVAC&R systems, but also to insufficient rigor in their energy analysis. Quantifying the energy consumption characteristics of HVAC&R system is complicated, because the energy savings provided by this system depend on various factors. This research evaluates energy consumption characteristics of HVAC&R systems, with the aim of establishing a common idea for the analysis of building energy efficiency. The objective of this study is to develop an energy evaluation methodology and a simple simulation program that may be used by engineers and designers to assess the effectiveness and economic benefits of HVAC&R systems. Our approach deals with the concept of HVAC&R system energy use aggregation levels that are composed of subsystems. To carry out a techno-economical estimation of HVAC&R systems considering different types of subsystems, the matrix combination analyzed, and a total of 960 HVAC&R systems can be implemented for a large-scale office building. The methodology of energy analysis that was carried out in this study highlights how to plan and design toward utilizing the most effective HVAC&R systems.

Jinkyun Cho; Seungho Shin; Jonghurn Kim; Hiki Hong

2014-01-01T23:59:59.000Z

133

Proposal for the award of a contract for the design, supply, installation and commissioning of an HVAC (Heating, Ventilation and Air Conditioning) system for Building 3862  

E-Print Network [OSTI]

Proposal for the award of a contract for the design, supply, installation and commissioning of an HVAC (Heating, Ventilation and Air Conditioning) system for Building 3862

2014-01-01T23:59:59.000Z

134

Proposal for the award of a contract for the design, supply, installation and commissioning of Heating, Ventilation and Air-Conditioning (HVAC) systems for the PS accelerator infrastructure  

E-Print Network [OSTI]

Proposal for the award of a contract for the design, supply, installation and commissioning of Heating, Ventilation and Air-Conditioning (HVAC) systems for the PS accelerator infrastructure

2012-01-01T23:59:59.000Z

135

Proposal to negotiate an amendment to an existing contract for the supply and installation of an HVAC system for the HIE-ISOLDE infrastructure  

E-Print Network [OSTI]

Proposal to negotiate an amendment to an existing contract for the supply and installation of an HVAC system for the HIE-ISOLDE infrastructure

2014-01-01T23:59:59.000Z

136

Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel  

E-Print Network [OSTI]

Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel

2012-01-01T23:59:59.000Z

137

Continuous Energy Management of the HVAC&R System in an Office Building System Operation and Energy Consumption for the Eight Years after Building Completion  

E-Print Network [OSTI]

The authors continuously studied the energy consumption of a heating, ventilating, air- conditioning and refrigerating (HVAC&R) system in an office for the operation of the system in terms of its expected performance. A fault in the system control...

Akashi, Y.; Shinozaki, M.; Kusuda, R.; Ito, S.

2006-01-01T23:59:59.000Z

138

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage Title Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage Publication Type Conference Proceedings Refereed Designation Refereed LBNL Report Number LBNL-6127E Year of Publication 2013 Authors Mammoli, Andrea, Michael Stadler, Nicholas DeForest, Hans Barsun, Richard Burnett, and Chris Marnay Conference Name 3rd International Conference on Microgeneration and Related Technologies Date Published 04/2013 Conference Location Naples, Italy Keywords absorption cooling, mixed integer programming, optimisation, software-as-a-service, thermal storage Abstract The UNM Mechanical Engineering HVAC system incorporates cooling assisted by a 232 m2 solar thermal array providing heat to a 70 kWthermal absorption chiller. A 30 m3 heat storage tank solar decouples heat production and absorption cooling. Additionally, 350 m3 of chilled water storage shifts the cooling electrical load of this high desert location off-peak. While this system already provides substantial energy and cost savings compared to similar conventional buildings, there are still opportunities for improvement. Absorption cooling (augmented by an electrically powered central cooling loop) suffers from parasitic electric loads from a cooling tower pump, a cooling tower fan, and hot and chilled water circulation pumps. Moreover, depending on seasonal, weather, occupancy, and cost conditions, the cold storage tanks may only need partial charging to meet the next day's net building load, and losses need to be considered. Optimally operating this complex thermal-electrical system poses a challenging mathematical problem. A model of the system was built on LBNL's Distributed Resources Customer Adoption Model (DER-CAM) platform. A direct interface between the building energy control system, and DER-CAM hosted on LBNL's server was developed. This interface delivers daily scheduling based on weather forecasts, tariffs, etc., to the building controller. It is found that energy cost savings can be proportionally substantial (almost 30%) - although in this case the payback period for system implementation is long, due to the very low energy consumption of the building. Also, it is found that accurate weather forecasting is a key ingredient of the optimization, although local biases can be corrected for in the optimization.

139

Methodology to Analyze the Sensitivity of Building Energy Consumption to HVAC System Sensor Error  

E-Print Network [OSTI]

Siemens TR 200/300 1 yr. (Siemens) GE Sensing Telaire 7000 1 yr.(GE-B,2011) 2.5.2 Pressure Sensors Based on the review of the manufacturers? specification literature, the most commonly used pressure sensors in HVAC systems are piezoresistive pressure... divided by the pump efficiency. Wpump=Wfluid/Effpump (42) Wpump(hp)=V(gal/min) ?Ptotal(ft-H2O)/(3960(gal-ft/min-hp)*Effpump) (43) The total pressure drop through the piping system includes the difference in static pressure of the inlet and outlet...

Ma, Liang

2012-02-14T23:59:59.000Z

140

NETL Sorbents Licensed to Help Lower Power Draw of HVAC  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

the energy efficiency of commercial HVAC (heating, ventilation, and air conditioning) systems. HVAC is one of the largest draws of electric power in the United States. In many...

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Combined solar and internal load effects on selection of heat reclaim-economizer HVAC systems  

SciTech Connect (OSTI)

The concern for energy conservation has led to the development and use of heat recovery systems which reclaim the building internal heat before it is discarded in the exhaust air. On the other hand, economizer cycles have been widely used for many years in a variety of types of HVAC systems. Economizer cycles are widely accepted as a means to reduce operating time for chilling equipment when cool outside air is available. It has been suggested that heat reclaim systems should not be used in conjunction with an HVAC system which incorporates an economizer cycle because the economizer operation would result in heat being exhausted which might have been recovered. Others suggest that the economizer cycle can be used economically in a heat recovery system if properly controlled to maintain an overall building heat balance. This study looks at potential energy savings of such combined systems with particular emphasis on the effects of the solar load (amount of glass) and the internal load level (lights, people, appliances, etc.). For systems without thermal storage, annual energy savings of up to 60 percent are predicted with the use of heat reclaim systems in conjunction with economizers when the heat reclaim has priority. These results demonstrate the necessity of complete engineering evaluations if proper selection and operation of combined heat recovery and economizer cycles are to be obtained. This paper includes the basic methodology for making such evaluations.

Sauer, H.J. Jr.; Howell, R.H.; Wang, Z. (Missouri Univ., Rolla, MO (USA). Dept. of Mechanical Engineering)

1990-05-01T23:59:59.000Z

142

Air filters from HVAC systems as possible source of volatile organic compounds (VOC) – laboratory and field assays  

Science Journals Connector (OSTI)

The emission of volatile organic compounds (VOC) from air filters of HVAC systems was to be evaluated. In a first study carbonyl compounds (14 aldehydes and two ketones) were measured by reacting them with 2,4-dinitrophenylhydrazine (DNPH). Analysis was done by HPLC and UV detection. In laboratory experiments pieces of used and unused HVAC filters were incubated in test chambers. Filters to be investigated were taken from a filter bank of a large HVAC system in the centre of Berlin. First results show that – among those compounds – formaldehyde and acetone were found in higher concentrations in the test chambers filled with used filters in comparison to those with unused filters. Parallel field measurements were carried out at the prefilter and main filter banks of the two HVAC systems. Here measurements were carried out simultaneously before and after the filters to investigate whether those aldehydes or ketones arise from the filter material on site. Formaldehyde and acetone significantly increased in concentration after the filters of one HVAC system. In parallel experiments microorganisms were proved to be able to survive on air filters. Therefore, a possible source of formaldehyde and acetone might be microbes.

Hans Schleibinger; Henning Rüden

1999-01-01T23:59:59.000Z

143

Energy efficient control of HVAC systems with ice cold thermal energy storage  

Science Journals Connector (OSTI)

Abstract In heating, ventilation and air conditioning (HVAC) systems of medium/high cooling capacity, energy demands can be matched with the help of thermal energy storage (TES) systems. If properly designed, TES systems can reduce energy costs and consumption, equipment size and pollutant emissions. In order to design efficient control strategies for TES systems, we present a model-based approach with the aim of increasing the performance of HVAC systems with ice cold thermal energy storage (CTES). A simulation environment based on Matlab/Simulink® is developed, where thermal behaviour of the plant is analysed by a lumped formulation of the conservation equations. In particular, the ice CTES is modelled as a hybrid system, where the water phase transitions (solid–melting–liquid and liquid–freezing–solid) are described by combining continuous and discrete dynamics, thus considering both latent and sensible heat. Standard control strategies are compared with a non-linear model predictive control (NLMPC) approach. In the simulation examples model predictive control proves to be the best control solution for the efficient management of ice CTES systems.

Alessandro Beghi; Luca Cecchinato; Mirco Rampazzo; Francesco Simmini

2014-01-01T23:59:59.000Z

144

Comparison of Building Energy Modeling Programs: HVAC Systems  

E-Print Network [OSTI]

Four Pipe Fan Coil; Four Pipe Induction Unit; Heating andTwo Pipe Fan Coil; Two Pipe Induction Unit; Unit Heater;units (AHUs) – four CAV systems, four VAV systems, and one fan coil

Zhou, Xin

2014-01-01T23:59:59.000Z

145

Co-simulation of innovative integrated HVAC systems in buildings  

E-Print Network [OSTI]

Developing an Integrated Building Design Tool by Couplingdesign energy ecient building systems in this complex setting, integrated

Trcka, Marija

2010-01-01T23:59:59.000Z

146

Case Study of an Innovative HVAC System with Integral Dehumidifier  

E-Print Network [OSTI]

prototype air conditioning/dehumidification system was initiated and focused on integrating a standalone room air dehumidifier and a conventional residential air handler into a single package. Potential benefits of the integrated system include lower... and construction of the prototype unit and the laboratory and field tests that were performed to evaluate the performance of the prototype system. Further details are available in the final task report (Raustad et al. 2007). PROTOTYPE CONSTRUCTION...

Shirey, D. B.; Raustad, R. A.

147

The Optimization of Control Parameters for VAV HVAC System Commissioning  

E-Print Network [OSTI]

, Menlo Park, CA. [6] L. Ljung 1995, ?System Identification Toolbox ? For Use with MATLAB 3rd ed, The MATH WORKS Inc, Natich, MA. [7] SIMULINK-Dynamic System Simulation for MATLAB-Using Simulink Ver.4, 2000, The MATH WORKS Inc, Natich, MA. ..., Menlo Park, CA. [6] L. Ljung 1995, ?System Identification Toolbox ? For Use with MATLAB 3rd ed, The MATH WORKS Inc, Natich, MA. [7] SIMULINK-Dynamic System Simulation for MATLAB-Using Simulink Ver.4, 2000, The MATH WORKS Inc, Natich, MA. ...

Song, S.; Maehara, K.; Sagara, N.

2006-01-01T23:59:59.000Z

148

Decentralized model predictive control of a multiple evaporator HVAC system  

E-Print Network [OSTI]

Vapor compression cooling systems are the primary method used for refrigeration and air conditioning, and as such are a major component of household and commercial building energy consumption. Application of advanced control techniques...

Elliott, Matthew Stuart

2009-05-15T23:59:59.000Z

149

Comparison of emerging diagnostic tools for large commercial HVAC systems  

SciTech Connect (OSTI)

Diagnostic software tools for large commercial buildings are being developed to help detect and diagnose energy and other performance problems with building operations. These software applications utilize energy management control system (EMCS) trend log data. Due to the recent development of diagnostic tools, there has been little detailed comparison among the tools and a limited awareness of tool capabilities by potential users. Today, these diagnostic tools focus mainly on air handlers, but the opportunity exists for broadening the scope of the tools to include all major parts of heating, cooling, and ventilation systems in more detail. This paper compares several tools in the following areas: (1) Scope, intent, and background; (2) Data acquisition, pre-processing, and management; (3) Problems detected; (4) Raw data visualization; (5) Manual and automated diagnostic methods and (6) Level of automation. This comparison is intended to provide practitioners and researchers with a picture of the current state of diagnostic tools. There is tremendous potential for these tools to help improve commercial building energy and non-energy performance.

Friedman, Hannah; Piette, Mary Ann

2001-04-06T23:59:59.000Z

150

CALIFORNIA ENERGY Small HVAC Database Of Monitored  

E-Print Network [OSTI]

CALIFORNIA ENERGY COMMISSION Small HVAC Database Of Monitored Information Database of Compiled of the Integrated Design of Small Commercial HVAC Systems research project. The reports are a result of funding: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

151

CALIFORNIA ENERGY Small HVAC Problems and Potential  

E-Print Network [OSTI]

CALIFORNIA ENERGY COMMISSION Small HVAC Problems and Potential Savings Reports Summary of Problems of the Integrated Design of Small Commercial HVAC Systems research project. The reports are a result of funding: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

152

Validation of a Building Simulation Tool Using Field Data for Three Identical Configuration Full-Serve Restaurants Using Different HVAC Systems  

E-Print Network [OSTI]

A new building application for a pre-existing HVAC software tool which calculates the benefits of desiccant-assisted HVAC equipment versus the performance of a standard vapor-compression system is used to model the monitored results, see Yborra...

Brillhart, P. L.; Worek, W. M.

2000-01-01T23:59:59.000Z

153

CALIFORNIA ENERGY Large HVAC Field and Baseline Data  

E-Print Network [OSTI]

CALIFORNIA ENERGY COMMISSION Large HVAC Field and Baseline Data Field Data Collection: Site Survey of the Integrated Design of Large Commercial HVAC Systems research project. The reports are a result of funding Design of Large Commercial HVAC Systems Integrated Design of Small Commercial HVAC Systems Integrated

154

HVAC: Maintaining HVAC equipment with air intake filters  

Science Journals Connector (OSTI)

Airborne debris, such as domestic waste, leaves, pollen, insects and even plastic carrier bags is the leading cause of fouling and clogging of cooling towers, heat exchangers, air cooled chillers and other HVAC systems. Richard Betts, managing director of UK-based RAB Specialist Engineers, provides Filtration+Separation with some practical advice on how to maintain HVAC equipment.

Richard Betts

2013-01-01T23:59:59.000Z

155

Development of a High-Efficiency Zonal Thermoelectric HVAC System for Automotive Applications  

Broader source: Energy.gov [DOE]

Identify a technical and business approach to accelerate the deployment of light-duty automotive TE HVAC technology, maintain occupant comfort, and improve energy efficiency.

156

Warming impact on energy use of HVAC system in buildings of different thermal qualities and in different climates  

Science Journals Connector (OSTI)

Abstract In order to combat climate change, energy use in the building must be further reduced. Heating ventilation and air conditioning (HVAC) systems in residential buildings account for considerable fraction of global energy consumption. The potential contribution the domestic sector can make in reducing energy consumption is recognized worldwide. The driving energy of \\{HVACs\\} depends on the thermal quality of the building envelope (TQBE) and outside temperature. Definitely, building regulations are changing with the time toward reduce the thermal loads of buildings. However, most of the existing residential buildings were built to lower TQBE. For instant, 72% of residential dwellings in the 15-EU were built before 1972. To investigate the impact of warming on driving energy of \\{HVACs\\} of a residential building a computer model was developed. Three climate categories/cities were considered, i.e. Stockholm (cold), Istanbul (mild), and Doha (hot). In each city, two buildings were modeled: one was assumed to be built according to the current local buildings regulations (standard TQBE), while the anther was built to lower TQBE. The simulations were run for present and future (in 2050) outdoor designing conditions. The calculations show that the impact of the warming on annual driving energy of \\{HVACs\\} (reduction or increase) depends very much on the climate category and on the TQBE. Based on the climate and TQBE, the change in annual \\{HVACs\\} energy varies from ?7.4% (in cold climate) to 12.7% (in hot climate). In mild climate, it was shown that the warming does not have significant impact on annual \\{HVACs\\} energy. Improving the TQBE can mitigate the impact of the warming.

Mohamad Kharseh; Lobna Altorkmany; Mohammed Al-Khawaj; Ferri Hassani

2014-01-01T23:59:59.000Z

157

PROJECT REPORT HVAC EQUIPMENT DEMOGRAPHICS AND CAPACITY  

E-Print Network [OSTI]

PROJECT REPORT HVAC EQUIPMENT DEMOGRAPHICS AND CAPACITY ANALYSIS TOOLS APPLICABLE TO MULTI Commercial HVAC Design Process 12 5.0 Conclusion 18 6.0 References 19 TABLE OF CONTENTS SECTIONS #12;MULTI performance by collectively improving the enve- lope, lighting and HVAC systems. The primary goals of the UC

California at Davis, University of

158

Proper Setup of HVAC System in Conjunction with Sound Building 'Skin' Design for Alleviation of IAQ and Energy Performance Problems  

E-Print Network [OSTI]

climates, not only because of the loss of energy, but also because of damage that can result to insulation, drywall, and structure in addition to promotion of mold and mildew growth. Proper setup of the HVAC system, in conjunction with sound building “skin...

Rosenberg, M.

2006-01-01T23:59:59.000Z

159

A comparative study on energy consumption for HVAC systems of high-tech \\{FABs\\}  

Science Journals Connector (OSTI)

The unique system dynamics of five different HVAC designs including the RCU (recirculation air unit) system, the MAU (make-up air unit) + RCU system, the MAU + RCU + FCU (fan coil unit) system, the MAU + axial fan system, and the MAU + FFU (fan-filter unit) system for a typical 200 mm DRAM wafer fabrication plant are discussed and compared. The energy performances of the RCU system, the MAU + RCU system, the MAU + RCU + FCU system, and the MAU + axial fan system are 3.8, 1.19, 1.12 and 1.08, respectively, folds that of the most efficient MAU + FFU system. The MAU + axial fan system exhibits slight less efficient in energy performance, compared with the MAU + FFU system. The most influential factor on energy performance between these two systems is the design of the noise abatement system, especially the pressure drop of the silencer, which dominates almost half of the internal static pressure of axial fan. When the static pressure of silencer of the MAU + axial fan system is reduced to 50 Pa, energy consumption of these two systems is comparable. Bypassing a certain portion of FAB return air to mix with make-up air can maximally reduce 50% of energy consumption of the RCU system.

Shih-Cheng Hu; Jhy-Ming Tsao

2007-01-01T23:59:59.000Z

160

Variable Speed Drive Volumetric Tracking (VSDVT) for Airflow Control in Variable Air Volume (VAV) Systems  

E-Print Network [OSTI]

Volume Systems.? Proceedings of ACEEE 1994 Summer Study on Energy Efficiency in Buildings, Vol. 5, pp. 219-223. 3. Liu M., Zhu Y., Claridge D.E., and White E., 1997. ?Impact of Static Pressure Set Level on HVAC Energy Consumption and Indoor... Volume Systems.? Proceedings of ACEEE 1994 Summer Study on Energy Efficiency in Buildings, Vol. 5, pp. 219-223. 3. Liu M., Zhu Y., Claridge D.E., and White E., 1997. ?Impact of Static Pressure Set Level on HVAC Energy Consumption and Indoor...

Liu, M.

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

HVAC Improvements for Existing Houses  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

HVAC Improvements for Existing Houses HVAC Improvements for Existing Houses Speaker(s): Chryséis Bovagnet Date: September 5, 2002 - 12:00pm Location: Bldg. 90 Many older houses in the US are either not well designed from a thermal point of view or have HVAC (Heating Ventilation and Air Conditioning) systems in need of repairs or improvements. The building envelopes tend to have poor insulation and lots of leakage, and the HVAC systems are inefficient. The cooling/heating equipment is often located outside of the conditioned space (e.g. in attics or crawlspaces) with ducts that leak and have poor insulation, which cause energy loss and bad occupant comfort on peak days or in extreme climates. We developed a series of retrofits that will allow us to reduce the energy consumption of residential HVAC

162

Strategy Guideline: HVAC Equipment Sizing  

SciTech Connect (OSTI)

The heating, ventilation, and air conditioning (HVAC) system is arguably the most complex system installed in a house and is a substantial component of the total house energy use. A right-sized HVAC system will provide the desired occupant comfort and will run efficiently. This Strategy Guideline discusses the information needed to initially select the equipment for a properly designed HVAC system. Right-sizing of an HVAC system involves the selection of equipment and the design of the air distribution system to meet the accurate predicted heating and cooling loads of the house. Right-sizing the HVAC system begins with an accurate understanding of the heating and cooling loads on a space; however, a full HVAC design involves more than just the load estimate calculation - the load calculation is the first step of the iterative HVAC design procedure. This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

Burdick, A.

2012-02-01T23:59:59.000Z

163

Dust loading on electrostatitically charged filters in a standard test and a real HVAC system  

Science Journals Connector (OSTI)

The efficiency and pressure drop of filters made from synthetic fibres carrying electrostatic charges and filters made from uncharged glass fibres were measured repeatedly for more than 19 weeks in operating HVAC systems. Results showed efficiency reductions as large as 40% for the filters made from charged fibres whereas the efficiency of filters made from uncharged fibres changed little. Clean filters were sent to a testing laboratory for efficiency measurements according to ASHRAE Standard 52.2-1999. When the filters experienced accelerated dust loading according to the ASHRAE procedure, the efficiency of both the glass and synthetic fibre filters increased. Efficiency reductions like those observed for the charged filters during actual use were not replicated by this standard test.

Peter C. Raynor; Soo Jae Chae

2003-01-01T23:59:59.000Z

164

2013 Energy Code Changes That Effect the HVAC  

E-Print Network [OSTI]

2013 Energy Code Changes That Effect the HVAC Industry Tav Commins Mechanical Engineer California Energy Commission #12;HVAC Mandatory Measures For All Newly Installed Residential HVAC Systems (New Watt Draw at .58 W/CFM, or (return duct and filter sizing) MERV 6 Filter #12;Residential HVAC Measures

California at Davis, University of

165

Airflow regulation in variable-speed systems for residential HVAC applications  

SciTech Connect (OSTI)

In the majority of heating, ventilating, and air-conditioning (HVAC) systems, air is the final medium for adding or extracting heat from or to the space to be air conditioned. Air is heated by passing it over a heat transfer device called a coil, which is a heat exchanger with air on the outside and the primary heating/cooling medium (water, steam, electricity, refrigerant, etc.) on the inside. One of the major factors determining heat transfer is the airflow rate, which can be controlled by mechanical means or by controlling the speed of the fan. Centrifugal fans driven by single-speed induction motors traditionally have been used in the JVAC industry but have an airflow characteristic that depends on the static pressure seen by the system. Variable-speed systems are starting to emerge as a strong alternative to traditional systems because of their ability to match the demand of the air-conditioned space, resulting in higher efficiencies and higher comfort. System efficiency can be improved by constraining the range of airflows provided by the fan or blower system in response to system pressure, that is, by controlling the airflow over the heat exchanger. This paper presents a method to regulate airflow independent of the static pressure and without the need for airflow sensors.

Becerra, R.C.; Beifus, B.L. [General Electric Co., Fort Wayne, IN (United States)

1996-11-01T23:59:59.000Z

166

Energy Savings Potential and RD&D Opportunities for Residential Building HVAC Systems  

Broader source: Energy.gov [DOE]

This report assesses 135 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. residential buildings to identify and provide analysis on 19 priority technology options in various stages of development.

167

HVAC efficiency: Can filter selection reduce HVAC energy costs?  

Science Journals Connector (OSTI)

In a society becoming more aware of the effects of energy consumption, Zoe Grainge takes a look at whether filter efficiency can go some way to ease the energy burden of HVAC systems.

Zoe Grainge

2007-01-01T23:59:59.000Z

168

Characterization of HVAC operation uncertainty in EnergyPlus AHU modules.  

E-Print Network [OSTI]

??This study addresses 5 uncertainties that exist in the operation of HVAC systems, which will presumably affect the actual energy consumption of the HVAC system… (more)

Sui, Di

2014-01-01T23:59:59.000Z

169

Performance analysis of supply and return fans for HVAC systems under different operating strategies of economizer dampers  

Science Journals Connector (OSTI)

HVAC systems and associated equipment consume a relatively large fraction of total building energy consumption, a significant portion of which is attributed to fan operation. The operation of economizer dampers when installed can cause high energy consumption in fans if they are not functioning in proper and optimal manner. This will mainly be due to the potential high pressure drops through those dampers and associated high total pressures that should be developed by supply and/or return fans. It is then necessary to ensure that a proper strategy to operate optimally the economizer dampers is implemented with minimum fan energy use. The paper examines several operation strategies of the economizer dampers and investigates their effects on the performance of both the supply and return fans in HVAC system. It also discusses a new operating strategy for economizer dampers that can lead to lower fan energy use. The strategies are evaluated by simulations for a typically existing HVAC system. Several factors such as the building locations, system characteristics, resistance in the duct where the dampers are installed, supply air temperature and economizer control, and minimum ventilation requirements are also considered during the evaluations. The results show that the way of the economizer dampers been controlled has a significant effect on fan performance and its energy use. The proposed strategy if properly implemented can provide fan energy saving in the range of 5–30%, depending mainly on the number of hours when the system operates in the free cooling mode, damper characteristics, and minimum outdoor air.

Nabil Nassif

2010-01-01T23:59:59.000Z

170

Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems  

Science Journals Connector (OSTI)

The capability of air filters (filterclass: F6, F7) to retain airborne outdoor microorganisms was examined in field experiments in two heating, ventilating and air conditioning (HVAC) systems. At the beginning of the 15-month investigation period, the first filter stages of both HVAC systems were equipped with new unused air filters. The number of airborne bacteria and molds before and behind the filters were determined simultaneously in 14 days-intervals using 6-stage Andersen cascade impactors. Under relatively dry ( 12 °C) outdoor air conditions air filters led to a marked reduction of airborne microorganism concentrations (bacteria by approximately 70 % and molds by > 80 %). However, during long periods of high relative humidity (> 80 % R. H.) a proliferation of bacteria on air filters with subsequent release into the filtered air occured. These microorganisms were mainly smaller than 1.1 ?m therefore being part of the respirable fraction. The results showed furthermore that one possibility to avoid microbial proliferation is to limit the relative humidity in the area of the air filters to 80 % R. H. (mean of 3 days), e. g. by using preheaters in front of air filters in HVAC-systems.

Martin Möritz; Hans Peters; Bettina Nipko; Hennin Rüden

2001-01-01T23:59:59.000Z

171

HVAC Commissioning - A Status Report in Taiwan  

E-Print Network [OSTI]

HVAC HVAC CommisioningCommisioning ?? A Status Report in TaiwanA Status Report in Taiwan Dr. K.H. YangDr. K.H. Yang Fellow ASHRAEFellow ASHRAEProfessor, National Sun Professor, National Sun Yat... ,decided to conduct an overall renovation program for the HVAC systems of existing governmental buildings where it is mandatory to adapt BEMS and conducting system commissioning .?This program not only constructs an important step in responding...

Yang, K. H.

2006-01-01T23:59:59.000Z

172

Radiant heating and cooling, displacement ventilation with heat recovery and storm water cooling: An environmentally responsible HVAC system  

SciTech Connect (OSTI)

This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.

Carpenter, S.C.; Kokko, J.P. [Enermodal Engineering Ltd., Kitchener, Ontario (Canada)

1998-12-31T23:59:59.000Z

173

HVAC Technician | Princeton Plasma Physics Lab  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

HVAC Technician HVAC Technician Department: Facilities Supervisor(s): Tom Ward Staff: L&S 07 Requisition Number: 1300884 Under the supervision of the General Lead Technician and Lead HVAC Technician, the incumbent will be responsible for the installation, preventative maintenance, troubleshooting and repair of various HVAC and refrigeration equipment; local HVAC control systems and ancillary support equipment; and will work with other groups within the Division and throughout the Laboratory to ensure long-term, safe and efficient operation of HVAC and refrigeration systems. All tasks must be completed in a timely, cost efficient manner, support on-going sustainability initiatives and energy efficiency programs at the Laboratory. The incumbent is expected to utilize thorough theoretical knowledge and techniques to accomplish

174

Adaptive HVAC zone modeling for sustainable buildings  

Science Journals Connector (OSTI)

Control of energy flows within a building is critical to achieving optimal performance of heating, ventilation and air-conditioning (HVAC) systems. To design optimal HVAC control strategies, a dynamic model of the HVAC system – particularly the building zones that it services – is essential. As analysis of building energy consumption is facilitated by the accurate prediction of indoor environmental conditions, techniques that dynamically model HVAC zones are crucial, and as such, is an active area of research. This paper focuses on real-time HVAC zone model fitting and prediction techniques based on physical principles, as well as the use of genetic algorithms for optimization. The proposed approach is validated by comparing real-time HVAC zone model fitting and prediction against the corresponding experimental measurements. In addition, comparison with prediction results using an algorithm based on feedback-delayed Kalman filters has demonstrated the superiority of the proposed approach in terms of prediction accuracy.

Glenn Platt; Jiaming Li; Ronxin Li; Geoff Poulton; Geoff James; Josh Wall

2010-01-01T23:59:59.000Z

175

EECBG Success Story: HVAC Upgrade Saving Money, Protecting History...  

Broader source: Energy.gov (indexed) [DOE]

HVAC Upgrade Saving Money, Protecting History EECBG Success Story: HVAC Upgrade Saving Money, Protecting History November 2, 2010 - 5:37pm Addthis A new heating and cooling system...

176

Modeling Building Thermal Response to HVAC Zoning Virginia Smith  

E-Print Network [OSTI]

Modeling Building Thermal Response to HVAC Zoning Virginia Smith Department of Computer Science HVAC systems account for 38% of building energy usage. Studies have indicated at least 5-15% waste due to unoccu- pied spaces being conditioned. Our goal is to minimize this waste by retrofitting HVAC systems

Whitehouse, Kamin

177

Lessons Learned During HVAC Installation Dept. of Computer Science  

E-Print Network [OSTI]

Lessons Learned During HVAC Installation Ian Watson AI-CBR Dept. of Computer Science University of HVAC equipment. It has been developed as an adjunct to an existing system that uses case-based reasoning to reuse previous HVAC installation specifications and designs. The system described lets

Watson, Ian

178

Duty-Cycling Buildings Aggressively: The Next Frontier in HVAC Control  

E-Print Network [OSTI]

Duty-Cycling Buildings Aggressively: The Next Frontier in HVAC Control Yuvraj Agarwal, Bharathan the dominant energy consumer is the HVAC system. Despite this fact, in most buildings the HVAC system is run sensing to guide the operation of a building HVAC system. We show how we can enable aggressive duty

Simunic, Tajana

179

An evaluation of technologies for real-time measurement of rates of outdoor airflow into HVAC systems  

SciTech Connect (OSTI)

During the last few years, new technologies have been introduced for real-time continuous measurement of the flow rates of outdoor air (OA) into HVAC systems; however, an evaluation of these measurement technologies has not previously been published. This document describes a test system and protocols developed for a controlled evaluation of these measurement technologies. The results of tests of four commercially available measurement technologies and one prototype based on a new design are also summarized. The test system and protocol were judged practical and very useful. The series of tests identified three commercially available measurement technologies that should provide reasonably accurate measurements of OA flow rates as long as air velocities are maintained high enough to produce accurately measurable pressure signals. In HVAC systems with economizer controls, to maintain the required air velocities the OA intake will need to be divided into two sections in parallel, each with a separate OA damper. The errors in OA flow rates measured with the fourth commercially available measurement technology were 20% to 30% with horizontal probes but much larger with vertical probes. The new prototype measurement technology was the only one that appears suitable for measuring OA flow rates over their full range from 20% OA to 100% OA without using two separate OA dampers. All of the measurement devices had pressure drops that are likely to be judged acceptable. The influence of wind on the accuracy of these measurement technologies still needs to be evaluated.

Fisk, William J.; Faulkner, David; Sullivan, Douglas P.

2004-09-01T23:59:59.000Z

180

An evaluation of three commercially available technologies forreal-time measurement of rates of outdoor airflow into HVAC systems  

SciTech Connect (OSTI)

During the last few years, new technologies have been introduced for real-time continuous measurement of the flow rates of outdoor air (OA) into HVAC systems; however, an evaluation of these measurements technologies has not previously been published. This document describes a test system and protocols developed for a controlled evaluation of these measurement technologies. The results of tests of three commercially available measurement technologies are also summarized. The test system and protocol were judged practical and very useful. The three commercially available measurement technologies should provide reasonably, e.g., 20%, accurate measurements of OA flow rates as long as air velocities are maintained high enough to produce accurately measurable pressure signals. In HVAC systems with economizer controls, to maintain the required air velocities the OA intake will need to be divided into two sections in parallel, each with a separate OA damper. All of the measurement devices had pressure drops that are likely to be judged acceptable. The influence of wind on the accuracy of these measurement technologies still needs to be evaluated.

Fisk, William J.; Faulkner, David; Sullivan, Douglas P.

2004-10-28T23:59:59.000Z

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Variation in indoor particle number and PM2.5 concentrations in a radio station surrounded by busy roads before and after an upgrade of the HVAC system  

Science Journals Connector (OSTI)

Indoor particle number and PM2.5 concentrations were investigated in a radio station surrounded by busy roads. Two extensive field measurement campaigns were conducted to determine the critical parameters affecting indoor air quality. The results indicated that indoor particle number and PM2.5 concentrations were governed by outdoor air, and were significantly affected by the location of air intake and design of HVAC system. Prior to the upgrade of the HVAC system and relocation of the air intake, the indoor median particle number concentration was 7.4×103 particles/cm3 and the median PM2.5 concentration was 7 ?g/m3. After the relocation of air intake and the redesign of the HVAC system, the indoor particle number concentration was between 2.3×103 and 3.4×103 particles/cm3, with a median value of 2.7×103 particles/cm3, and the indoor PM2.5 concentration was in the range of 3–5 ?g/m3, with a median value of 4 ?g/m3. By relocating the air intake of the HVAC, the outdoor particle number and PM2.5 concentrations near the air intake were reduced by 35% and 55%, respectively. In addition, with the relocation of air intake and the redesign of the HVAC system, the particle number penetration rate was reduced from 42% to 14%, and the overall filtration efficiency of the HVAC system (relocation of air intake, pre-filter, AHU and particle losses in the air duct) increased from 58% to 86%. For PM2.5, the penetration rate after the upgrade was approximately 18% and the overall filtration efficiency was 82%. This study demonstrates that by using a comprehensive approach, including the assessment of outdoor conditions and characterisation of ventilation and filtration parameters, satisfactory indoor air quality can be achieved, even for those indoor environments facing challenging outdoor air conditions.

L. Morawska; M. Jamriska; H. Guo; E.R. Jayaratne; M. Cao; S. Summerville

2009-01-01T23:59:59.000Z

182

MATERIALS AND INFORMATION FLOWS FOR HVAC DUCTWORK FABRICATION AND SITE  

E-Print Network [OSTI]

MATERIALS AND INFORMATION FLOWS FOR HVAC DUCTWORK FABRICATION AND SITE INSTALLATION Matt Holzemer,1, and air-conditioning (HVAC) systems requires a set of complex activities and handoffs between multiple architecture-, engineering-, and construction practitioners. This paper highlights one part of the HVAC

Tommelein, Iris D.

183

Modeling and simulation of HVAC Results in EnergyPlus  

E-Print Network [OSTI]

LBNL-5564E Modeling and simulation of HVAC Results in EnergyPlus Mangesh Basarkar, Xiufeng Pang;MODELING AND SIMULATION OF HVAC FAULTS IN ENERGYPLUS Mangesh Basarkar, Xiufeng Pang, Liping Wang, Philip not capture the significant impact of installation, operational and degradation HVAC system faults on actual

184

Deposition of Biological Aerosols on HVAC Heat Exchangers  

E-Print Network [OSTI]

LBNL-47669 Deposition of Biological Aerosols on HVAC Heat Exchangers Jeffrey Siegel and Iain Walker of Biological Aerosols on HVAC Heat Exchangers Jeffrey A. Siegel Iain S. Walker, Ph.D. ASHRAE Student Member that are found in commercial and residential HVAC systems of 1 - 6 m/s (200 - 1200 ft/min), particle diameters

185

Commercial Building HVAC: How it Affects People  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Commercial Building HVAC: How it Affects People Commercial Building HVAC: How it Affects People Speaker(s): William Fisk Date: November 13, 2000 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: David Faulkner Commercial building heating, ventilating, and air conditioning (HVAC) systems are designed primarily to maintain a reasonable level of thermal comfort while limiting first costs and energy consumption. However, research conducted predominately within the last decade suggests that commercial building HVAC significantly influences human outcomes other than thermal comfort, including the health, satisfaction, and work performance of the building's occupants. This presentation will review the relationships of these outcomes with HVAC system type, filtration system efficiency, indoor air temperature, and outside air ventilation rate.

186

Development Practice in HVAC Controls  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Development Practice in HVAC Controls Development Practice in HVAC Controls Speaker(s): John Zhou Date: April 11, 2011 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Philip Haves The presentation will introduce development tools and design considerations used in HVAC controls development. Controls development use simulation, lab testing and field trial at different phases of the project cycle to improve control performance and to achieve rapid development. Development starts with simulation to originate and define algorithm concept. The concept is then implemented in a prototype controller, and tested in lab environment. The concept is refined and verified by analyzing lab results. In the final phase of development, controllers with refined and verified algorithms are installed in field trial sites to ensure system integration and to confirm

187

NREL's Advanced Thermal Conversion Laboratory at the Center for Buildings and Thermal Systems: On the Cutting-Edge of HVAC and CHP Technology (Revised)  

SciTech Connect (OSTI)

This brochure describes how the unique testing capabilities of NREL's Advanced Thermal Conversion Laboratory at the Center For Buildings and Thermal Systems can help industry meet the challenge of developing the next generation of heating, ventilating, and air-conditioning (HVAC) and combined heat and power (CHP) equipment and concepts.

Not Available

2005-09-01T23:59:59.000Z

188

HVAC Maintenance and Technologies  

Broader source: Energy.gov (indexed) [DOE]

HVAC - HVAC - Maintenance and Technologies Federal Utility Partnership Working Group Meeting Providence, Rhode Island April 15, 2010 BY Ramin Faramarzi, P.E. Technology Test Centers (TTC) Design and Engineering Services Southern California Edison (SCE) www.sce.com/rttc 2 Outline * Introduction to SCE's TTC * Overview of energy challenges in California (CA) * Role of HVAC in CA's energy and demand equations * Factors affecting HVAC performance * Focus on SCE's research on maintenance faults * Next generation of HVAC equipment * HVAC technologies on SCE's TTC radar * Black boxes - do they all work? 3 SCE's Technology Test Centers * SCE applied research facilities located in Irwindale, CA comprised of 3 test beds: * Refrigeration * HVAC * Lighting * Coming Soon! - A new ZNE lab 4 Refrigeration Testing

189

Assessment of organic compound exposures, thermal comfort parameters, and HVAC system-driven air exchange rates in public school portable classrooms in California  

E-Print Network [OSTI]

no no, y e s - only HVAC filters: sizes, when changed 68%n=2) (n=19) 100% no 95% no Current HVAC air filter was notoriginal When HVAC air filter was last changed (reported as

Shendell, Derek Garth

2010-01-01T23:59:59.000Z

190

Evaluation of commercially available techniques and development of simplified methods for measuring grille airflows in HVAC systems  

SciTech Connect (OSTI)

In this report, we discuss the accuracy of flow hoods for residential applications, based on laboratory tests and field studies. The results indicate that commercially available hoods are often inadequate to measure flows in residential systems, and that there can be a wide range of performance between different flow hoods. The errors are due to poor calibrations, sensitivity of existing hoods to grille flow non-uniformities, and flow changes from added flow resistance. We also evaluated several simple techniques for measuring register airflows that could be adopted by the HVAC industry and homeowners as simple diagnostics that are often as accurate as commercially available devices. Our test results also show that current calibration procedures for flow hoods do not account for field application problems. As a result, organizations such as ASHRAE or ASTM need to develop a new standard for flow hood calibration, along with a new measurement standard to address field use of flow hoods.

Walker, Iain S.; Wray, Craig P.; Guillot, Cyril; Masson, S.

2003-08-01T23:59:59.000Z

191

Interdisciplinary Innovation and Vision in the HVAC  

E-Print Network [OSTI]

potentials for optimizing costs can be found in the HVAC systems when calculated over the total Life-Cycle-Cost (LCC) of a building incorporating planning through to facility management. This requires an accurate plan specifying an efficient technical...

Hecker, T.

2008-01-01T23:59:59.000Z

192

HVAC Maintenance and Technologies  

Broader source: Energy.gov [DOE]

Presentation covers the HVAC maintenance and technologies, and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Providence, Rhode Island.

193

Methodology for design, calibration, system identification and operation of an experimental Hvac system.  

E-Print Network [OSTI]

??It is well known that building control systems rarely function as designed, contributing to excessive energy use and poor environmental control performance. In addition, most… (more)

Cui, Li

2013-01-01T23:59:59.000Z

194

Ozone removal by HVAC filters  

Science Journals Connector (OSTI)

Residential and commercial HVAC filters that have been loaded with particles during operation in the field can remove ozone from intake or recirculated air. However, knowledge of the relative importance of HVAC filters as a removal mechanism for ozone in residential and commercial buildings is incomplete. We measured the ozone removal efficiencies of clean (unused) fiberglass, clean synthetic filters, and field-loaded residential and commercial filters in a controlled laboratory setting. For most filters, the ozone removal efficiency declined rapidly but converged to a non-zero (steady-state) value. This steady-state ozone removal efficiency varied from 0% to 9% for clean filters. The mean steady-state ozone removal efficiencies for loaded residential and commercial filters were 10% and 41%, respectively. Repeated exposure of filters to ozone following a 24-h period of no exposure led to a regeneration of ozone removal efficiency. Based on a theoretical scaling analysis of mechanisms that are involved in the ozone removal process, we speculate that the steady-state ozone removal efficiency is limited by reactant diffusion out of particles, and that regeneration is due to internal diffusion of reactive species to sites available to ozone for reaction. Finally, by applying our results to a screening model for typical residential and commercial buildings, HVAC filters were estimated to contribute 22% and 95%, respectively, of total ozone removal in HVAC systems.

P. Zhao; J.A. Siegel; R.L. Corsi

2007-01-01T23:59:59.000Z

195

Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating Ventilation and Air Conditioning (HVAC) system for the HIE-ISOLDE infrastructure  

E-Print Network [OSTI]

Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating Ventilation and Air Conditioning (HVAC) system for the HIE-ISOLDE infrastructure

2012-01-01T23:59:59.000Z

196

Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre  

E-Print Network [OSTI]

Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

2012-01-01T23:59:59.000Z

197

Ventilation, temperature, and HVAC characteristics in small and medium  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ventilation, temperature, and HVAC characteristics in small and medium Ventilation, temperature, and HVAC characteristics in small and medium commercial buildings in California Title Ventilation, temperature, and HVAC characteristics in small and medium commercial buildings in California Publication Type Journal Article Refereed Designation Refereed Year of Publication 2012 Authors Bennett, Deborah H., William J. Fisk, Michael G. Apte, X. Wu, Amber L. Trout, David Faulkner, and Douglas P. Sullivan Journal Indoor Air Volume 22 Issue 4 Pagination 309-20 Abstract This field study of 37 small and medium commercial buildings throughout California obtained information on ventilation rate, temperature, and heating, ventilating, and air-conditioning (HVAC) system characteristics. The study included seven retail establishments; five restaurants; eight offices; two each of gas stations, hair salons, healthcare facilities, grocery stores, dental offices, and fitness centers; and five other buildings. Fourteen (38%) of the buildings either could not or did not provide outdoor air through the HVAC system. The air exchange rate averaged 1.6 (s.d. = 1.7) exchanges per hour and was similar between buildings with and without outdoor air supplied through the HVAC system, indicating that some buildings have significant leakage or ventilation through open windows and doors. Not all buildings had sufficient air exchange to meet ASHRAE 62.1 Standards, including buildings used for fitness centers, hair salons, offices, and retail establishments. The majority of the time, buildings were within the ASHRAE temperature comfort range. Offices were frequently overcooled in the summer. All of the buildings had filters, but over half the buildings had a filter with a minimum efficiency reporting value rating of 4 or lower, which are not very effective for removing fine particles. PRACTICAL IMPLICATIONS: Most U.S. commercial buildings (96%) are small- to medium-sized, using nearly 18% of the country's energy, and sheltering a large population daily. Little is known about the ventilation systems in these buildings. This study found a wide variety of ventilation conditions, with many buildings failing to meet relevant ventilation standards. Regulators may want to consider implementing more complete building inspections at commissioning and point of sale.

198

The impact of filter loading on residential hvac performance.  

E-Print Network [OSTI]

??Buildings are the primary user of energy in the USA. Within homes, the heating, ventilation, and air condition (HVAC) system is the largest energy consumer.… (more)

Kruger, Abraham J.

2013-01-01T23:59:59.000Z

199

HVAC Efficiency Controls Could Mean Significant Savings | Department of  

Broader source: Energy.gov (indexed) [DOE]

HVAC Efficiency Controls Could Mean Significant Savings HVAC Efficiency Controls Could Mean Significant Savings HVAC Efficiency Controls Could Mean Significant Savings April 27, 2012 - 11:58am Addthis HVAC Efficiency Controls Could Mean Significant Savings April Saylor April Saylor Former Digital Outreach Strategist, Office of Public Affairs What does this mean for me? Commercial building owners could save an average 38% on their heating & cooling bills just by installing a few new controls onto their HVAC systems. According to a new report from Pacific Northwest National Lab, commercial building owners could save an average 38 percent on their heating and cooling bills just by installing a few new controls onto their HVAC systems. These findings mean significant potential savings for building owners who use commercial rooftop systems - but there's just one problem: the

200

Modeling and Optimal Control Algorithm Design for HVAC Systems in Energy Efficient Buildings  

E-Print Network [OSTI]

Litz. Simulation of thermal building behaviour in modelica.of the 2nd International Modelica Conference, volume 154.building behaviour using Modelica. Mathematical and Computer

Maasoumy, Mehdi

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

A robust CO2-based demand-controlled ventilation control strategy for multi-zone HVAC systems  

Science Journals Connector (OSTI)

There have been increasingly growing concerns over the quality of the air inside buildings and the associated energy use. The CO2-based demand-controlled ventilation DCV is one of the strategies that could offer a great opportunity to reduce energy consumption in HVAC systems. However, implementing CO2-based DCV under ASHRAE Standard 62.1 2004–2010 is not simple as it was under previous versions due to the changes in breathing-zone ventilating rate calculations. Thus, this paper provides insight into the performance of a multi-zone VAV system under different operating and ventilation conditions, discusses the difficulties in the CO2-based DCV, and proposes a robust DCV strategy based on the supply air CO2 concentration. The proposed strategy offers great benefits in terms of better indoor air control and improved energy efficiency. To evaluate the proposed strategy, energy simulations were performed on various USA locations and for a typical two-story office building conditioned by a VAV system. The results show that a significant energy saving could be achieved by implementing the proposed strategy as compared to the design-occupancy ASHRAE Standard 62.1 2010 multi-zone procedure and the amount of saving that could be up to 23% depends mainly on locations and the actual occupancy profile.

Nabil Nassif

2012-01-01T23:59:59.000Z

202

Optimal supply air temperature with respect to energy use in a variable air volume system  

Science Journals Connector (OSTI)

In a variable air volume (VAV) system with 100% outdoor air, the cooling need in the building is satisfied with a certain air flow at a certain supply air temperature. To minimize the system energy use, an optimal supply air temperature can be set dependent on the load, specific fan power (SFP), chiller coefficient of performance, outdoor temperature and the outdoor relative humidity. The theory for an optimal supply air temperature is presented and the heating, ventilation and air-conditioning (HVAC) energy use is calculated depending on supply air temperature control strategy, average U-value of the building envelope and two outdoor climates. The analyses show that controlling the supply air temperature optimally results in a significantly lower HVAC energy use than with a constant supply air temperature. The optimal average U-value of the building envelope is in practise mostly zero.

Fredrik Engdahl; Dennis Johansson

2004-01-01T23:59:59.000Z

203

System Effects of High Efficiency Filters in Homes  

E-Print Network [OSTI]

FIELD TESTING OF FILTER IMPACTS ON HVAC SYSTEM PERFORMANCEof Filters in Residential and Light-Commercial HVAC systems.HVAC system performance changes with different MERV filters

Walker, Iain S.

2014-01-01T23:59:59.000Z

204

TITLE: HVAC TESTING & BALANCING FOR MAJOR AND MINOR PROJECTS OBJECTIVE AND  

E-Print Network [OSTI]

TITLE: HVAC TESTING & BALANCING FOR MAJOR AND MINOR PROJECTS OBJECTIVE AND PURPOSE: To provide an independent test & balance for the adjustment of all HVAC systems in all major projects and minor projects

Fernandez, Eduardo

205

VOLUME 11, NUMBER 4 HVAC&R RESEARCH OCTOBER 2005 A Model for Annual Simulation of Standing  

E-Print Network [OSTI]

wells. An approach that uti- lizes an "enhanced" thermal conductivity to account for the natural ­ Standing column well (SCW) systems, which utilize a single well for both extraction and injection of groundwater ­ Open-loop groundwater systems with separate extraction and injection wells or single extraction

206

Wireless Infrastructure for Performing Monitoring, Diagnostics, and Control HVAC and Other Energy-Using Systems in Small Commercial Buildings  

SciTech Connect (OSTI)

This project focused on developing a low-cost wireless infrastructure for monitoring, diagnosing, and controlling building systems and equipment. End users receive information via the Internet and need only a web browser and Internet connection. The system used wireless communications for: (1) collecting data centrally on site from many wireless sensors installed on building equipment, (2) transmitting control signals to actuators and (3) transmitting data to an offsite network operations center where it is processed and made available to clients on the Web (see Figure 1). Although this wireless infrastructure can be applied to any building system, it was tested on two representative applications: (1) monitoring and diagnostics for packaged rooftop HVAC units used widely on small commercial buildings and (2) continuous diagnosis and control of scheduling errors such as lights and equipment left on during unoccupied hours. This project developed a generic infrastructure for performance monitoring, diagnostics, and control, applicable to a broad range of building systems and equipment, but targeted specifically to small to medium commercial buildings (an underserved market segment). The proposed solution is based on two wireless technologies. The first, wireless telemetry, is used for cell phones and paging and is reliable and widely available. This risk proved to be easily managed during the project. The second technology is on-site wireless communication for acquiring data from sensors and transmitting control signals. The technology must enable communication with many nodes, overcome physical obstructions, operate in environments with other electrical equipment, support operation with on-board power (instead of line power) for some applications, operate at low transmission power in license-free radio bands, and be low cost. We proposed wireless mesh networking to meet these needs. This technology is relatively new and has been applied only in research and tests. This proved to be a major challenge for the project and was ultimately abandoned in favor of a directly wired solution for collecting sensor data at the building. The primary reason for this was the relatively short ranges at which we were able to effectively place the sensor nodes from the central receiving unit. Several different mesh technologies were attempted with similar results. Two hardware devices were created during the original performance period of the project. The first device, the WEB-MC, is a master control unit that has two radios, a CPU, memory, and serves as the central communications device for the WEB-MC System (Currently called the 'BEST Wireless HVAC Maintenance System' as a tentative commercial product name). The WEB-MC communicates with the local mesh network system via one of its antennas. Communication with the mesh network enables the WEB-MC to configure the network, send/receive data from individual motes, and serves as the primary mechanism for collecting sensor data at remote locations. The second antenna enables the WEB-MC to connect to a cellular network ('Long-Haul Communications') to transfer data to and from the NorthWrite Network Operations Center (NOC). A third 'all-in-one' hardware solution was created after the project was extended (Phase 2) and additional resources were provided. The project team leveraged a project funded by the State of Washington to develop a hardware solution that integrated the functionality of the original two devices. The primary reason for this approach was to eliminate the mesh network technical difficulties that severely limited the functionality of the original hardware approach. There were five separate software developments required to deliver the functionality needed for this project. These include the Data Server (or Network Operations Center), Web Application, Diagnostic Software, WEB-MC Embedded Software, Mote Embedded Software. Each of these developments was necessarily dependent on the others. This resulted in a challenging management task - requiring high bandwidth communications among

Patrick O'Neill

2009-06-30T23:59:59.000Z

207

HVAC Installed Performance  

Broader source: Energy.gov [DOE]

This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question HVAC proper installation energy savings: over-promising or under-delivering?"

208

Modeling Building Thermal Response to HVAC Virginia Smith, Tamim Sookoor, and Kamin Whitehouse  

E-Print Network [OSTI]

Modeling Building Thermal Response to HVAC Zoning Virginia Smith, Tamim Sookoor, and Kamin,sookoor,whitehouse}@virginia.edu Abstract. HVAC systems account for 38% of building energy usage. Studies have indicated at least 5 HVAC systems to enable room-level zoning where each room is conditioned in- dividually based on its

Whitehouse, Kamin

209

A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2  

E-Print Network [OSTI]

A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2 3 4 Peng Xu, Philip Haves HVAC system (air handling units and air distribution systems). The models are used to predict of automatic documentation methods in the library. INTRODUCTION The increasing complexity of building HVAC

210

Chapter 5: Lighting, HVAC, and Plumbing  

Broader source: Energy.gov (indexed) [DOE]

: Lighting, : Lighting, HVAC, and Plumbing High-Performance Engineering Design Lighting System Design Mechanical System Design Central Plant Systems Plumbing and Water Use Building Control Systems Electrical Power Systems Metering LANL | Chapter 5 High-Performance Engineering Design Lighting, HVAC, and Plumbing By now, the building envelope serves multiple roles. It protects the occupants from changing weather condi- tions and it plays a key part in meeting the occupants' comfort needs. The heating, ventilating, air-conditioning, and lighting (HVAC&L) systems complement the archi- tectural design, govern the building's operation and maintenance costs, and shape the building's long-term environmental impact. The architectural design maximizes the potential for a high-performance building, but it is the

211

ETME 422 -REFRIGERATION & HVAC SYSTEMS FALL 2011 LEC -10:00 -10:50am M W F RH 312  

E-Print Network [OSTI]

-1209(h) Office Hours: M-F 1-2p.m. Text: Heating, Ventilating, and Air Conditioning - Analysis and Design. -- Refrigeration and heating, ventilating and air-conditioning (HVAC) for comfort and industrial applications of the fundamentals of Heating, Ventilating, Air Conditioning, and Refrigeration as they relate to human comfort

Dyer, Bill

212

Sentinel: Occupancy Based HVAC Actuation using Existing WiFi Infrastructure within Commercial Buildings  

E-Print Network [OSTI]

Sentinel: Occupancy Based HVAC Actuation using Existing WiFi Infrastructure within Commercial.agarwal@cs.cmu.edu ABSTRACT Commercial buildings contribute to 19% of the primary energy consumption in the US, with HVAC systems accounting for 39.6% of this usage. To reduce HVAC energy use, prior studies have pro- posed using

Gupta, Rajesh

213

Multi-carrier Signal Transmission through HVAC Ducts: Experimental Results for Channel Capacity  

E-Print Network [OSTI]

Multi-carrier Signal Transmission through HVAC Ducts: Experimental Results for Channel Capacity, for the first time, experimental results on channel capacity of heating, ventilation, and air-conditioning (HVAC through a building HVAC duct system demonstrate the ability to transmit with a spectral efficiency of 3

Stancil, Daniel D.

214

Improving efficiency of a vehicle HVAC system with comfort modeling, zonal design, and thermoelectric devices  

Broader source: Energy.gov [DOE]

Discusses progress on thermal comfort modeling and detailed design, fabrication, and component/system-level testing of TE architecture

215

An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings  

E-Print Network [OSTI]

Developing an Integrated Building Design Tool by Couplingdesign energy efficient building systems in this complex setting, integrated

Trcka, Marija

2010-01-01T23:59:59.000Z

216

Building Energy Software Tools Directory: HVAC 1 Toolkit  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

HVAC 1 Toolkit HVAC 1 Toolkit HVAC 1 Toolkit logo. The Toolkit for Primary HVAC System Energy Calculations is a collection of thirty-eight separate subroutines and corresponding documentation that describes algorithms for predicting the performance of HVAC components. The Toolkit documentation includes thorough descriptions of the component models and solution algorithms, detailed information on the structure of the individual FORTRAN 77 routines, as well as illustrative examples of system simulations with the Toolkit routines. The Toolkit serves two purposes: modules for large-scale simulation and stand-alone component performance prediction. The Toolkit components can also be used to calculate the energy performance of a component with a dedicated driver program to provide the necessary information flow to the Toolkit routines.

217

HVAC | OpenEI  

Open Energy Info (EERE)

HVAC HVAC Dataset Summary Description The following data-set is for a benchmark residential home for all TMY3 locations across all utilities in the US. The data is indexed by utility service provider which is described by its "unique" EIA ID ( Source National Renewable Energy Laboratory Date Released April 05th, 2012 (2 years ago) Date Updated April 06th, 2012 (2 years ago) Keywords AC apartment CFL coffeemaker Computer cooling cost demand Dishwasher Dryer Furnace gas HVAC Incandescent Laptop load Microwave model NREL Residential television tmy3 URDB Data text/csv icon Residential Cost Data for Common Household Items (csv, 14.5 MiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually Time Period License License Open Data Commons Public Domain Dedication and Licence (PDDL)

218

Development of a Thermoelectric Device for an Automotive Zonal HVAC System  

Broader source: Energy.gov [DOE]

Presents development of a thermoelectric device using liquid working fluid on the waste? side and air as working fluid on the main? side to enable zonal or distributed heating/cooling systems within a vehicle

219

A BEMS-Assisted Commissioning Tool to Improve the Energy Performance of HVAC Systems  

E-Print Network [OSTI]

The evolving capabilities of Building Energy Management Systems (BEMS) offer new opportunities to automate some parts of the commissioning process and can generate benefits over the entire life of a building. These benefits include a reduction...

Choiniere, D.; Corsi, M.

2003-01-01T23:59:59.000Z

220

Thermal Modeling for a HVAC Controlled Real-life Yong Fu1, Mo Sha1, Chengjie Wu1, Andrew Kutta1, Anna Leavey2, Chenyang Lu1,  

E-Print Network [OSTI]

Thermal Modeling for a HVAC Controlled Real-life Auditorium Yong Fu1, Mo Sha1, Chengjie Wu1, Andrew consumption in build- ings is heating, ventilation, and air conditioning (HVAC). For an HVAC system to provide, especially in large open spaces. To optimize HVAC control, it is important to establish accurate dynamic

Lu, Chenyang

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Analysis of the Design of an HVAC System in a Public Building  

E-Print Network [OSTI]

to west, 2.5 meters high, 1560 m2 in area, fire resistant rating, with four exists. It is planed the reconstructed as a public building with the function of amusement, recreation and performance, so the air conditioning system is necessary...

Wei, P.; Shao, Z.; Chen, H.

2006-01-01T23:59:59.000Z

222

Life Cycle cost Analysis of Waste Heat Operated Absorption Cooling Systems for Building HVAC Applications  

E-Print Network [OSTI]

was used to calculate the PWC of the system for annual operating hours of 8760 and the same is compared with the electric based vapour compression chiller (VCRS) of same capacity. The life cycle cost (LCC) of waste heat operated absorption chiller...

Saravanan, R.; Murugavel, V.

2010-01-01T23:59:59.000Z

223

Heat recovery highlighted in state-of-the-art HVAC system  

SciTech Connect (OSTI)

The new $35 million corporate headquarters building of Steelcase, Inc., provides 385,000 sq. ft. of office space and support areas for more than 500 employees. The building embodies state-of-the-art energy storage and heat recovery systems, and the extensive use of computers to predict, monitor, and control space comfort conditions. The heat storage and recovery equipment are described.

Speyer, J.R.

1984-11-01T23:59:59.000Z

224

Phase-change wallboard and mechanical night ventilation in commercial buildings: Potential for HVAC system downsizing  

SciTech Connect (OSTI)

As thermal storage media, phase-change materials (PCMs) such as paraffin, eutectic salts, etc. offer an order-of-magnitude increase in thermal storage capacity, and their discharge is almost isothermal. By embedding PCMs in dypsum board, plaster, or other wall-covering materials, the building structure acquires latent storage properties. Structural elements containing PCMs can store large amounts of energy while maintaining the indoor temperature within a relatively narrow range. As heat storage takes place inside the building where the loads occur, rather than at a central exterior location, the internal loads are removed without the need for additional transport energy. Distributed latent storage can thus be used to reduce the peak power demand of a building, downsize the cooling system, and/or switch to low-energy cooling sources. The authors used RADCOOL, a thermal building simulation program based on the finite difference approach, to numerically evaluate the thermal performance of PCM wallboard coupled with mechanical night ventilation in office buildings offers the opportunity for system downsizing in climates where the outside air temperature drops below 18 C at night. In climates where the outside air temperature remains above 19 C at night, the use of PCM wallboard should be coupled with discharge mechanisms other than mechanical night ventilation with outside air.

Stetiu, C.; Feustel, H.E.

1998-07-01T23:59:59.000Z

225

A Method for On-Going Commissioning of VRV Package Systems Using a Simulation Model  

E-Print Network [OSTI]

Variable refrigerant volume (VRV) systems, which have several indoor units and a single outdoor unit, have become very popular HVAC systems in Japan. However, some systems may be operated under inefficient conditions and consume excessive energy...

Yamaha, M.; Sekiyama, K.; Misaki, S.

2006-01-01T23:59:59.000Z

226

HVAC-systems.  

E-Print Network [OSTI]

?? It is of interest for companies to keep the annual operating cost of their buildings as low as possible. A substantial share of the… (more)

Alvsvåg, Øyvind

2011-01-01T23:59:59.000Z

227

A study on static pressure reset and instability in variable air volume HVAC systems.  

E-Print Network [OSTI]

??This project began with testing five different versions of supply duct static pressure reset strategies that fall into two general categories: Proportional plus Integral control… (more)

Housholder, Brian Wayne

2011-01-01T23:59:59.000Z

228

A Quasi-Dynamic HVAC and Building Simulation Methodology  

E-Print Network [OSTI]

This thesis introduces a quasi-dynamic building simulation methodology which complements existing building simulators by allowing transient models of HVAC (heating, ventilating and air-conditioning) systems to be created in an analogous way...

Davis, Clinton Paul

2012-07-16T23:59:59.000Z

229

Columbia Water and Light- Residential HVAC Rebate Program  

Broader source: Energy.gov [DOE]

Columbia Water and Light (CWL) provides an HVAC incentive for residential customers that are replacing an older heating and cooling system. Customers should submit the mechanical permit from a...

230

EECBG Success Story: HVAC Upgrade Saving Money, Protecting History  

Broader source: Energy.gov [DOE]

With financial support from a $250,000 PA Conservation Works! grant – funded through the federal Energy Efficiency and Conservation Block Grant program and the Recovery Act – CCHS purchased a new Desert-Aire HVAC system. Learn more.

231

The Impact of Uncertain Physical Parameters on HVAC Demand Response  

SciTech Connect (OSTI)

HVAC units are currently one of the major resources providing demand response (DR) in residential buildings. Models of HVAC with DR function can improve understanding of its impact on power system operations and facilitate the deployment of DR technologies. This paper investigates the importance of various physical parameters and their distributions to the HVAC response to DR signals, which is a key step to the construction of HVAC models for a population of units with insufficient data. These parameters include the size of floors, insulation efficiency, the amount of solid mass in the house, and efficiency of the HVAC units. These parameters are usually assumed to follow Gaussian or Uniform distributions. We study the effect of uncertainty in the chosen parameter distributions on the aggregate HVAC response to DR signals, during transient phase and in steady state. We use a quasi-Monte Carlo sampling method with linear regression and Prony analysis to evaluate sensitivity of DR output to the uncertainty in the distribution parameters. The significance ranking on the uncertainty sources is given for future guidance in the modeling of HVAC demand response.

Sun, Yannan; Elizondo, Marcelo A.; Lu, Shuai; Fuller, Jason C.

2014-03-01T23:59:59.000Z

232

Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1  

E-Print Network [OSTI]

LBL-34045 UC-1600 Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting-uses include Heating, Ventilation and Air Conditioning (HVAC). Our analysis uses the modeling framework provided by the HVAC module in the Residential End-Use Energy Planning System (REEPS), which was developed

233

7/11/00-draft copy: do not quote 1 of 30 New Technologies for Residential HVAC Ducts  

E-Print Network [OSTI]

7/11/00-draft copy: do not quote 1 of 30 New Technologies for Residential HVAC Ducts Burke Treidler is not evaluated and HVAC contractors overcome duct system shortcomings by installing oversized equipment Technologies for Residential HVAC Ducts fittings with some use of ductboard. Fittings that snap together were

234

E-Print Network 3.0 - air conditioning hvac Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

systems play an important role in providing comfort in residential, commercial... of Heating, Refrigerating, and Air-Conditioning Engineers. Batterman S. and Burge H. 1995. "HVAC...

235

Diagnosis of Effectiveness of HVAC System and Energy Performance of Osaka-Gas Building through Retro-Commissioning Part 1 Outline of HVAC Systems and Diagnosis of Energy Efficiency of Air Systems  

E-Print Network [OSTI]

-22b AC-22a AC-22b INV Output 97% (58.2Hz) 84% (50.4Hz) 70% (40.8Hz) Air volume at the outlet duct 87,848 m3/h 56,968 m3/h 42,635 m3/h Power consumption 70.0kW 46.8kW 20.6kW Outlet static pressure 854Pa 798Pa 802Pa 5F MD... 2013 Note 1: Circles (?) in Figure 6.1 represent operating points of the fans alone. Triangles (?) represent operating air volumes calculated based on the fan’s static pressure. Note 2: Numbers in boxes ??? represent air volume measurement...

Hatanaka,T.; Aoki,K; Matsuda, N.; Yamaha,M.; Tanaka,H.; Nakahara,N.

2014-01-01T23:59:59.000Z

236

Chapter 19: HVAC Controls (DDC/EMS/BAS) Evaluation Protocol  

SciTech Connect (OSTI)

The HVAC Controls Evaluation Protocol is designed to address evaluation issues for direct digital controls/energy management systems/building automation systems (DDC/EMS/BAS) that are installed to control heating, ventilation, and air-conditioning (HVAC) equipment in commercial and institutional buildings. (This chapter refers to the DDC/EMS/BAS measure as HVAC controls.) This protocol may also be applicable to industrial facilities such as clean rooms and labs, which have either significant HVAC equipment or spaces requiring special environmental conditions. This protocol addresses only HVAC-related equipment and the energy savings estimation methods associated with installing such control systems as an energy efficiency measure. The affected equipment includes: Air-side equipment (air handlers, direct expansion systems, furnaces, other heating- and cooling-related devices, terminal air distribution equipment, and fans); Central plant equipment (chillers, cooling towers, boilers, and pumps). These controls may also operate or affect other end uses, such as lighting, domestic hot water, irrigation systems, and life safety systems such as fire alarms and other security systems. Considerable nonenergy benefits, such as maintenance scheduling, system component troubleshooting, equipment failure alarms, and increased equipment lifetime, may also be associated with these systems. When connected to building utility meters, these systems can also be valuable demand-limiting control tools. However, this protocol does not evaluate any of these additional capabilities and benefits.

Romberger, J.

2014-11-01T23:59:59.000Z

237

High-Speed Internet Access via HVAC Ducts: A New Approach Daniel D. Stancil, Ozan K. Tonguz, Ariton Xhafa, Ahmet Cepni, and Pavel Nikitin  

E-Print Network [OSTI]

High-Speed Internet Access via HVAC Ducts: A New Approach Daniel D. Stancil, Ozan K. Tonguz, Ariton conditioning (HVAC) ducts for indoor wireless transmission systems and networks. Mea- surements and system to 100 Mbps should be possible, when HVAC system is used in con- junction with OFDM technology. Keywords

Stancil, Daniel D.

238

Modeling of Solar-Powered Single-Effect Absorption Cooling System and Supermarket Refrigeration/HVAC System.  

E-Print Network [OSTI]

??This thesis consists of two different research problems. In the first one, the aim is to model and simulate a solar-powered, single-effect, absorption refrigeration system… (more)

Bahman, Ammar

2011-01-01T23:59:59.000Z

239

Chapter 4, Small Commercial and Residential Unitary and Split System HVAC Cooling Equipment-Efficiency Upgrade Evaluation Protocol: The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures  

Broader source: Energy.gov (indexed) [DOE]

4: Small Commercial 4: Small Commercial and Residential Unitary and Split System HVAC Cooling Equipment-Efficiency Upgrade Evaluation Protocol David Jacobson, Jacobson Energy Research Subcontract Report NREL/SR-7A30-53827 April 2013 The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures 4 - 1 Chapter 4 - Table of Contents 1 Measure Description .............................................................................................................. 2 2 Application Conditions of Protocol ....................................................................................... 3 2.1 Programs with Enhanced Measures ................................................................................. 5 3 Savings Calculations .............................................................................................................. 6

240

Fouling of HVAC Fin and Tube Heat Exchangers Jeffrey Siegel and Van P. Carey  

E-Print Network [OSTI]

Fouling of heat exchangers used in heating, ventilating, and air conditioning (HVAC) systems is important contributor to overall energy use and peak electric demand. Furthermore, the location of heat exchangers in HVAC systems means that if bioaerosols containing bacteria, fungi, and viruses deposit on heat

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Removal of submicron particles using a carbon fiber ionizer-assisted medium air filter in a heating, ventilation, and air-conditioning (HVAC) system  

Science Journals Connector (OSTI)

Laboratory tests of particle removal were performed with a pair of carbon fiber ionizers installed upstream of a glass fiber air filter. For air flow face velocities of 0.4, 0.6, and 0.8 m/s, the overall particle removal efficiencies of the filter for all submicron particles were 17%, 16%, and 14%, respectively, when the ionizers were not turned on. These values increased to 27%, 23%, and 19%, respectively, when the ionizers were used to generate ions of 6.0 × 109 ions/cm3 in concentration. The carbon fiber ionizers were then installed in front of a glass fiber air filter located in a heating, ventilation, and air-conditioning (HVAC) system. Field tests were performed in a test office room with a total indoor particle concentration of 2.2 × 104 particles/cm3. When the flow rate was 75 cubic meters per hour (CMH), the steady-state values of the total indoor particle concentrations using the glass fiber air filter with and without ionizers decreased to 0.87 × 104 particles/cm3 and 1.15 × 104 particles/cm3, respectively, resulting in a 25% decrease of the ionizer effect. When the operation flow rate was increased to 115 and 150 CMH, the effect of the ionizer decreased to 19% and 17%, respectively. These experimental data match the results calculated using a mass-balance model whose parameters were determined from laboratory tests.

Jae Hong Park; Ki Young Yoon; Jungho Hwang

2011-01-01T23:59:59.000Z

242

IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, VOL. 51, NO. 5, MAY 2003 945 Propagation Model for the HVAC Duct as a  

E-Print Network [OSTI]

for the HVAC Duct as a Communication Channel Pavel V. Nikitin, Member, IEEE, Daniel D. Stancil, Senior Member (HVAC) ducts in buildings are typically hollow metal pipes which can be used as waveguides to carry such a communication system. This paper presents a propagation model for a straight HVAC duct terminated at both ends

Stancil, Daniel D.

243

Application of Multizone HVAC Control Using Wireless Sensor Networks and Actuating Vent Registers  

E-Print Network [OSTI]

Most residential heating, ventilating, and air conditioning (HVAC) systems are designed to treat the home as a single zone. Single zone control consists of one thermostat, in a central area of the house that controls the HVAC operation. In a single...

Watts, W.; Koplow, M.; Redfern, A.; Wright, P.

2007-01-01T23:59:59.000Z

244

A plug and play framework for an HVAC air handling unit and temperature sensor auto recognition technique.  

E-Print Network [OSTI]

??A plug and play framework for an HVAC air handling unit control system is proposed in this study. This is the foundation and the first… (more)

Zhou, Xiaohui

2010-01-01T23:59:59.000Z

245

MODELING PARTICLE DEPOSITION ON HVAC HEAT EXCHANGERS  

E-Print Network [OSTI]

LBNL-49339 MODELING PARTICLE DEPOSITION ON HVAC HEAT EXCHANGERS J.A. Siegel1,3 * and W.W. Nazaroff2 Department of Energy under contract DE-AC03-76SF00098. #12;MODELING PARTICLE DEPOSITION ON HVAC HEAT, such as discontinuities in the fins, are hypothesized to be responsible for the discrepancy. INDEX TERMS HVAC, Fouling

246

Development of New HVAC Design Tools: Search for the Holy Grail of  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Development of New HVAC Design Tools: Search for the Holy Grail of Development of New HVAC Design Tools: Search for the Holy Grail of Ventilation Research Speaker(s): Jelena Srebric Date: January 29, 2004 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: William Fisk HVAC systems are very important to our wellbeing, energy, and the environment. Current design tools are typically supported by basic knowledge, and keep us at arm's length from the many practical problems. The design paradigm has been shifted several times in the past from thermal comfort, energy conservation, health concerns, and now probably to security issues. Each of the shift has required better design tools of HVAC systems.A team led by Dr. Jelena Srebric at the Department of Architecture, the Penn State University (PSU) is developing new HVAC design tools to meet

247

This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)  

E-Print Network [OSTI]

at Oklahoma State University (www.hvac.okstate.edu) The correct citation for the paper is: Xiao, D., J) and may become part of the ASHRAE standard method of test for whole building energy simulation programs (ASHRAE Standard 140). The existing test suite is comprised of tests that use a single building zone

248

This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)  

E-Print Network [OSTI]

at Oklahoma State University (www.hvac.okstate.edu) The correct citation for the paper is: Pedersen, C.O., D in the NBSLD program developed at the US National Bureau of Standards (now NIST) in the same time period of Standards (now NIST). The DOE eff

249

Best practices guide for residential HVAC Retrofits  

SciTech Connect (OSTI)

This best practices guide for residential HVAC system retrofits is aimed at contractors who want guidance on delivering energy efficient, cost effective and innovative products. It has been developed around the idea of having packages of changes to the building HVAC system and building envelope that are climate and house construction dependent. These packages include materials, procedures and equipment and are designed to remove some of the guesswork from a builder, contractor, installer or homeowner decisions about how best to carry out HVAC changes. The packages are not meant to be taken as rigid requirements--instead they are systems engineered guidelines that form the basis for energy efficient retrofits. Similar approaches have been taken previously for new construction to develop extremely energy efficient homes that are comfortable safe and durable, and often cost less than standard construction. This is best epitomized by the Building America program whose partners have built thousands of residences throughout the U.S. using these principles. The differences between retrofitting and new construction tend to limit the changes one can make to a building, so these packages rely on relatively simple and non-intrusive technologies and techniques. The retrofits also focus on changes to a building that will give many years of service to the occupants. Another key aspect of these best practices is that we need to know how a house is working so that we know what parts have the potential for improvement. To do this we have put together a set of diagnostic tools that combine physical measurements and checklists/questionnaires. The measured test results, observations and homeowner answers to questions are used to direct us towards the best retrofits applicable to each individual house. The retrofits will depend on the current condition of the building envelope and HVAC system, the local climate, the construction methods used for the house, and the presence of various energy saving systems (e.g., a Heat Recovery Ventilator) and/or materials. This is just like a doctor referring a patient for blood tests or x-rays before actually performing surgery. This way the doctor can be sure that he does the right thing. To take this analogy further--we can borrow from the medical profession and say that the first thought when retrofitting a house is to do no harm, i.e., do not make changes that could make the house worse to live in.

Walker, Iain S.

2003-08-11T23:59:59.000Z

250

Model Predictive Control Approach to Online Computation of Demand-Side Flexibility of Commercial Buildings HVAC Systems for Supply Following  

E-Print Network [OSTI]

the summation of fan power, cooling power and heating power,non-electric heating and cooling powers of these systems. (time t Power consumption of fan, heating and cooling systems

Maasoumy, Mehdi

2014-01-01T23:59:59.000Z

251

Software tools for HVAC research  

Science Journals Connector (OSTI)

Energy saving methods can be employed to reduce energy consumption in buildings, or improve indoor thermal conditions. An example of those methods is the use of permeable coverings, but there are other important parameters like thermal inertia. To understand ... Keywords: Building, Computer, Design, Energy saving, HVAC, Software tools

José A. Orosa; Armando C. Oliveira

2011-10-01T23:59:59.000Z

252

STATE OF CALIFORNIA CERTIFICATE OF COMPLIANCE, PRESCRIPTIVE HVAC ALTERATIONS  

E-Print Network [OSTI]

STATE OF CALIFORNIA CERTIFICATE OF COMPLIANCE, PRESCRIPTIVE HVAC ALTERATIONS CEC-MECH-1C-ALT-HVAC (Revised 07/10) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE MECH-1C-ALT-HVAC Prescriptive HVAC Steps" column below. Note: After installation of HVAC units and/or ducts, the Installation

253

Indirect Benefits (Increased Roof Life and HVAC Savings) from a Solar PV System at the San José Convention Center  

Broader source: Energy.gov [DOE]

The City of San José is considering the installation of a solar photovoltaic (PV) system on the roof of the San José Convention Center. The installation would be on a lower section of the roof covering approximately 21,000 ft2. To assist city staff in making a decision on the PV installation, the Department of Energy Tiger Team has investigated potential indirect benefits of installing a solar PV system on the Convention Center roof. The indirect benefits include potential increase in roof life, as well as potential reduced heating and cooling load in the building due to roof shading from the PV system.

254

Optimizing HVAC Control to Improve Building Comfort and Energy Performance  

E-Print Network [OSTI]

This paper demonstrates the benefits of optimal control in well-designed and operated buildings using a case study. The case study building was built in 2001. The HVAC and control systems have been installed with state-of-the-art equipment which...

Song, L.; Joo, I.; Dong, D.; Liu, M.; Wang, J.; Hansen, K.; Quiroz, L.; Swiatek, A.

2003-01-01T23:59:59.000Z

255

Cold Vacuum Drying facility personnel monitoring system design description (SYS 12)  

SciTech Connect (OSTI)

This document describes the Cold Vacuum Drying Facility (CVDF) instrument air (IA) system that provides instrument quality air to the CVDF. The IA system provides the instrument quality air used in the process, HVAC, and HVAC instruments. The IA system provides the process skids with air to aid in the purging of the annulus of the transport cask. The IA system provides air for the solenoid-operated valves and damper position controls for isolation, volume, and backdraft in the HVAC system. The IA system provides air for monitoring and control of the HVAC system, process instruments, gas-operated valves, and solenoid-operated instruments. The IA system also delivers air for operating hand tools in each of the process bays.

PITKOFF, C.C.

1999-07-06T23:59:59.000Z

256

Combining HVAC energy conservation measures to achieve energy savings over standard requirements  

Science Journals Connector (OSTI)

Abstract This paper presents the energy savings over the minimum American Society of Heating Refrigeration and Air-Conditioning Engineers (ASHRAE) Standard 90.1-2010 requirements due to the combination of two or three HVAC energy conservation measures using EnergyPlus simulation software. Prototype commercial building models, which satisfy the requirements of ASHRAE Standard 90.1-2010 were used as base-cases. Five prototype commercial buildings, eight HVAC systems, and eight climate zones were considered. Four cases were studied for the combination: energy recovery ventilation (ERV) and demand control ventilation (DCV); ERV and Multiple-zone variable air volume (VAV) System Ventilation Optimization (VentOpt); ERV, DCV and VentOpt; and Single Zone VAV controls, and kitchen transfer air. Of the four cases studied, the integration of ERV and DCV, which was applied to primary school and standalone retail prototype buildings, provided a maximum savings of 1.93% and 8.10% respectively compared to the base-cases.

Teshome Edae Jiru

2014-01-01T23:59:59.000Z

257

Empirical Methodologies for Improving HVAC Efficiency  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Empirical Methodologies for Improving HVAC Efficiency Empirical Methodologies for Improving HVAC Efficiency Speaker(s): Anil Aswani Date: September 21, 2012 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Michael Wetter This talk describes the use of empirical methodologies that we have developed for the purpose of improving heating, ventilation, and air-conditioning (HVAC) efficiency through better control algorithms and configuration. We show that semiparametric regression can both identify simplified models of thermal HVAC dynamics while also estimating time-varying heating loads using only real-time temperature measurements from thermostats. These models can be used with our learning-based model predictive control (LBMPC) method in order to improve the energy-efficiency of HVAC. Experiments on testbeds with different types of HVAC show the

258

Application of Various HVAC Simulation Programs and Visual Tools to Commissioning  

E-Print Network [OSTI]

Various existing HVAC system simulation programs and visualization tools are considered to be potentially powerful tools for commissioning. Although not originally developed as commissioning tools, these programs facilitate the confirmation...

Zheng, M.; Pan, S.

2007-01-01T23:59:59.000Z

259

Building America Whole-House Solutions for Existing Homes: Inverted Attic Bulkhead for HVAC Ductwork  

Broader source: Energy.gov [DOE]

This occupied test home received a modified truss system to accommodate ductwork within an inverted insulated bulkhead along the attic floor, which saves energy by placing heating, ventilating, and air-conditioning (HVAC) ductwork within the home's thermal boundary.

260

HVAC, Water Heating, and Appliances | Department of Energy  

Energy Savers [EERE]

HVAC, Water Heating, and Appliances HVAC, Water Heating, and Appliances How a Small Business is Transforming the Cold Climate Heating Market How a Small Business is Transforming...

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Energy Department Releases Roadmaps on HVAC Technologies, Water...  

Energy Savers [EERE]

Energy Department Releases Roadmaps on HVAC Technologies, Water Heating, Appliances, and Low-GWP Refrigerants Energy Department Releases Roadmaps on HVAC Technologies, Water...

262

DOE Convening Report on Certification of Commercial HVAC and...  

Broader source: Energy.gov (indexed) [DOE]

Convening Report on Certification of Commercial HVAC and CRE Products DOE Convening Report on Certification of Commercial HVAC and CRE Products This document is the convening...

263

Solid State Vehicular Generators and HVAC Development | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Solid State Vehicular Generators and HVAC Development Solid State Vehicular Generators and HVAC Development 2009 DOE Hydrogen Program and Vehicle Technologies Program Annual Merit...

264

Chapter 5: Lighting, HVAC, and Plumbing | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

5: Lighting, HVAC, and Plumbing Chapter 5: Lighting, HVAC, and Plumbing Chapter 5 of the LANL Sustainable Design Guide with guidelines for developing sustainable, healthy,...

265

Utveckling av provmetodik för HVAC på lastbil; Development of test methodology for climatic testing of truck HVAC on trucks.  

E-Print Network [OSTI]

?? I detta examensarbetet undersöks hur provningen av HVAC på lastbilar skall utföras i klimatvindtunneln CD7 som Scania färdigställer till år 2013. HVAC omfattar kupéuppvärmning,… (more)

Jonsson, Björn-Emil

2011-01-01T23:59:59.000Z

266

Coordinated Control of HVAC Systems  

E-Print Network [OSTI]

This paper describes the development of new control logic for starting and stopping energy-intensive equipment in buildings such as staged air-conditioning units. The concept is to use pulse-width modulation (PWM) instead of level-crossing logic. A...

Federspiel, C.; Lanning, S. D.; Li, H.; Auslander, D. M.

2001-01-01T23:59:59.000Z

267

VOLUME 11, NUMBER 2 HVAC&R RESEARCH APRIL 2005 Ground-Source Heat Pump System Research--  

E-Print Network [OSTI]

discussion in Sanner, B. 2001. Some history of shallow geothermal energy use. International Summer School on Direct Application of Geothermal Energy, Skopje. Available online at http

268

Optimization Control Strategies for HVAC Terminal Boxes  

E-Print Network [OSTI]

The HVAC terminal boxes are one of the major building HVAC components. They directly impact the building room comfort conditions and the energy costs. How to operate the box in a highly energy efficient way and maintain the room comfort level...

Zhu, Y.; Batten, T.; Noboa, H.; Claridge, D. E.; Turner, W. D.; Liu, M.; Zhou, J.; Cameron, C.; Keeble, D.; Hirchak, R.

2000-01-01T23:59:59.000Z

269

Free-cooling: A total HVAC design concept  

SciTech Connect (OSTI)

This paper discusses a total ''free cooling'' HVAC design concept in which mechanical refrigeration is practically obviated via the refined application of existing technological strategies and a new diffuser terminal. The principles being applied are as follows; Thermal Swing: This is the active contribution of programmed heat storage to overall HVAC system performance. Reverse Diffuser: This is a new air terminal design that facilitates manifesting the thermal storage gains. Developing the thermal storage equation system into a generalized simulation model, optimizing the thermal storage and operating strategies with a computer program and developing related algorithms are subsequently illustrated. Luminair Aspiration: This feature provides for exhausting all luminair heat totally out of the building envelope, via an exhaust duct system and insulated boots. Two/Three-Stage Evaporative Cooling: This concept comprises a system of air conditioning that entails a combination of closed and open loop evaporative cooling with standby refrigeration only.

Janeke, C.E.

1982-01-01T23:59:59.000Z

270

Quantitative Methods for Comparing Different HVAC Control Schemes  

E-Print Network [OSTI]

Experimentally comparing the energy usage and comfort characteristics of different controllers in heating, ventilation, and air-conditioning (HVAC) systems is difficult because variations in weather and occupancy conditions preclude the possibility of establishing equivalent experimental conditions across the order of hours, days, and weeks. This paper is concerned with defining quantitative metrics of energy usage and occupant comfort, which can be computed and compared in a rigorous manner that is capable of determining whether differences between controllers are statistically significant in the presence of such environmental fluctuations. Experimental case studies are presented that compare two alternative controllers (a schedule controller and a hybrid system learning-based model predictive controller) to the default controller in a building-wide HVAC system. Lastly, we discuss how our proposed methodology may also be able to quantify the efficiency of other building automation systems.

Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

2012-01-01T23:59:59.000Z

271

Variable Refrigerant Flow HVAC  

E-Print Network [OSTI]

Conference, San Antonio, Texas Dec. 16-18 What do they know that we don’t know? Japan 90% Over 7 Million Systems China 86% Over 17 Million Systems Europe 81% Over 7 Million Systems USA 4% .5 Million Systems ESL-KT-13-12-33 CATEE 2013: Clean Air Through...-source VRF IEER 11.5 - 17.7 19.6 9.7 10.3 10.9 10.5 IPLV - 14.2 - - SCHE - - 18.6 N/A Energy Efficiency - commercial EER ESL-KT-13-12-33 CATEE 2013: Clean Air Through Energy Efficiency Conference, San Antonio, Texas Dec. 16-18 More Comfort & Quiet ? 4 ton...

Jones, S.

2013-01-01T23:59:59.000Z

272

Unusual HVAC challenges require innovative solutions  

SciTech Connect (OSTI)

There were many reasons behind Motorola`s decision to build the first 225,000 sq ft of a planned one million sq ft manufacturing facility in Chihuahua, Mexico. Among these were the availability of skilled labor in the area, lower construction costs, some export tax advantages, and the close proximity to the US border. The new facility is made up of a variety of functional areas that together create an impressively efficient plant. Phase 1 construction included a large manufacturing floor, shipping and receiving areas, a bulk storage facility, and a large office area with a view of the factory floor. The structure also houses a retail store where Motorola consumer products are sold, a conference and banquet center, a commercial kitchen, and dining facilities for 750. The design cooling load is 750 tons; the heating load is 4.5 million Btuh. The paper discusses the challenging location, the HVAC system, and the future expansion planned.

Jardine, G.M.; Gwin, O.D. [Heery International, Inc., Atlanta, GA (United States)

1998-02-01T23:59:59.000Z

273

Cooling and Dehumidification HVAC Technology for 1990s  

E-Print Network [OSTI]

Desiccant Cooling and Dehumidification HVAC Technology for 1990s HVAC: Heating, Ventilation Research Trusts SERI #12;Challenges Facing HVAC Industry in 1990's * Reduction of CFCs * Indoor air quality to solve the problems of the HVAC industry faced in1990's for space conditioning. SERI #12;l- = m mN a- mg

Oak Ridge National Laboratory

274

Residential HVAC Indoor Air Quality(ASHRAE 62.2)  

E-Print Network [OSTI]

Residential HVAC && Indoor Air Quality(ASHRAE 62.2) Tav Commins #12;Contact Information · Energy construction, Additions /Alterations · Nonresidential and Residential #12;Residential HVAC && Indoor Air Quality(ASHRAE 62.2) ·HVAC EfficiencyHVAC Efficiency ·Quality Installation (HERS Measures) S li b HERS R t

275

Particle loading rates for HVAC filters, heat exchangers, and ducts Nomenclature  

E-Print Network [OSTI]

Particle loading rates for HVAC filters, heat exchangers, and ducts Nomenclature Afl surface area of floor (m2 ) bf fraction of bypass flow around the filter (dimensionless) Cout outdoor concentration on the filter per volume of air (mg/lm m3 ) Mf,tot total mass deposited on the filter per month of operation (g

Siegel, Jeffrey

276

Investigation of IAQ-Relevant Surface Chemistry and Emissions on HVAC Filter Materials  

E-Print Network [OSTI]

VOCs emitted by reactions of HVAC filters with ozone usingand Emissions on HVAC Filter Materials Hugo Destaillats andChemistry and Emissions on HVAC Filter Materials Authors:

Destaillats, Hugo

2010-01-01T23:59:59.000Z

277

HVAC Optimized Heat Exchangers Research Project | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Optimized Heat Exchangers Research Optimized Heat Exchangers Research Project HVAC Optimized Heat Exchangers Research Project The U.S. Department of Energy is currently conducting research into heating, ventilation, and air conditioning (HVAC) optimized heat exchangers. The information generated in this study will demonstrate performance improvements that can be achieved through optimization of refrigerant circuitry for non-uniform inlet air distribution. The tubing circuitry on fin-tube heat exchangers used in residential space-conditioning systems is typically designed assuming uniform airflow through the finned passageways. However, the air flow in installed systems is highly non-uniform, resulting in mismatched refrigerant-air heat transfer that reduces the capacity of the heat exchanger and efficiency of

278

Bus HVAC energy consumption test method based on HVAC unit behavior  

Science Journals Connector (OSTI)

This paper presents a test method for determination of energy consumption of bus HVAC unit. The energy consumption corresponds to a bus engine fuel consumption increase during the HVAC unit operation period. The HVAC unit energy consumption is determined from the unit input power, which is measured under several levels of bus engine speeds and at different levels of testing heat load in the laboratory environment. Since the bus engine fuel consumption is incrementally induced by powering an HVAC unit, the results are subsequently recalculated to the unit fuel consumption under the defined road cycles in terms of standardized diesel engine. The method is likewise applicable either for classic or electric HVAC units with a main consumer (compressor or high voltage alternator) mechanically driven directly from the bus engine and also for electric HVAC units supplied from an alternative electric energy source in case of hybrid or fully electric buses.

M. Hegar; M. Kolda; M. Kopecka; V. Rajtmajer; A. Ryska

2013-01-01T23:59:59.000Z

279

Utveckling av provmetodik för HVAC på lastbil; Development of test methodology for truck HVAC.  

E-Print Network [OSTI]

?? The issue about how Scania shall perform HVAC tests in the climatic wind tunnel CD7, which Scania is about to complete by year 2013,… (more)

Tedenäs, Jimmy

2011-01-01T23:59:59.000Z

280

BS-8: HVAC Modeling and Simulation  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

BS-8: HVAC Modeling and Simulation BS-8: HVAC Modeling and Simulation Speaker(s): Darko Sucic Date: December 5, 2001 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Satkartar K. Kinney Industry Foundation Classes (IFC), an object data model of buildings, are being developed by the International Alliance for Interoperability (IAI) to support data sharing and exchange in the building and construction industry. The IAI, founded in 1995, has published four releases of IFC so far. Several prototype implementations by leading software companies show that commercial IFC software is beginning to meet end user expectations of interoperability in the industry. BS-8 is an LBNL project that started last summer. It is developing the IFC HVAC extension schemata that will extend the IFC object data model and support the exchange of HVAC information

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

HVAC Equipment Rebate Program | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

HVAC Equipment Rebate Program HVAC Equipment Rebate Program HVAC Equipment Rebate Program < Back Eligibility Agricultural Commercial Industrial Installer/Contractor Institutional Multi-Family Residential Nonprofit Schools Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Heat Pumps Maximum Rebate Rebates of greater than $5,000 require pre-approval Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Varies depending on technology and efficiency Provider Efficiency Vermont NOTE: Rebate reservations are required for all boiler and furnace projects. Efficiency Vermont offers rebates for commercial installations of high-efficiency HVAC equipment and controls. For businesses and purchases

282

Recovery Act-Funded HVAC projects  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy was allocated funding from the American Recovery and Reinvestment Act to conduct research into heating, ventilation, and air conditioning (HVAC) technologies and...

283

HVAC Energy Recovery Design and Economic Evaluation  

E-Print Network [OSTI]

ENRECO has prepared this paper on HVAC energy recovery to provide the engineer with an overview of the design engineering as well as the economic analysis considerations necessary to evaluate the potential benefits of energy recovery....

Kinnier, R. J.

1979-01-01T23:59:59.000Z

284

Non-Vapor Compression HVAC Technologies Report  

Broader source: Energy.gov [DOE]

While vapor-compression technologies have served heating, ventilation, and air-conditioning (HVAC) needs very effectively, and have been the dominant HVAC technology for close to 100 years, the conventional refrigerants used in vapor-compression equipment contribute to global climate change when released to the atmosphere. The Building Technologies Office is evaluating low-global warming potential (GWP) alternatives to vapor-compression technologies.

285

Building Technologies Office: HVAC Optimized Heat Exchangers Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Optimized Heat Optimized Heat Exchangers Research Project to someone by E-mail Share Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Facebook Tweet about Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Twitter Bookmark Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Google Bookmark Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Delicious Rank Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Digg Find More places to share Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research Building Envelope Research

286

Section 38 - HVAC (Heating, Ventilation, Air Conditioning)  

Science Journals Connector (OSTI)

The term HVAC is an acronym for Heating, Ventilation (and) Air Conditioning, the industry term for any of various efforts to control conditions in a building or other enclosed area to improve comfort and efficiency. A closely related section is Refrigeration, which follows this one. Some contemporary HVAC techniques have ancient roots. Early forms of central heating and solar home heating were in use in Rome in the first century A.D. The earliest use of glass in windows (as opposed to a covering of wood, cloth, or hide, or simply an opening) is also attributed to the Romans at this same time. The first known use of solar-oriented building design in North America dates back to about the year 1050; i.e., the cliff dwellings built by the Anasazi (Ancient Pueblo) people of the Colorado Plateau area. Geothermal district heating was employed as early as the 1300s, in the Auvergne region of southern France. The foundation for modern central heating was established in the 1700s, first in England and then in France. The 1800s saw significant advances in the use of water heaters, especially the first automatic storage water heater (Edwin Ruud, 1889) and the first commercial solar water heater (Clarence Kemp, 1891). In comparison with heating, cooling technology was late in developing. The first successful method of producing ice occurred in 1851, and it was not until 1902 that Willis Haviland Carrier designed the first industrial air-conditioning system. His Carrier Air Conditioning Corporation would go on to develop air-conditioning systems for stores and theaters (1924) and for residential buildings (1928). Carrier remains the global leader in air conditioner production. The first air-conditioned automobile was produced by Packard in 1939. Recent entries in this section emphasize the use of alternative energy sources in heating and cooling, such as solar, photovoltaic, geothermal, and fuel cells. These advances include the ground-source heat pump, the Trombe wall, the heat pipe, and the PV/thermal hybrid system.

Cutler J. Cleveland; Christopher Morris

2014-01-01T23:59:59.000Z

287

Building America Whole-House Solutions for New Homes: HVAC Design Strategy for a Hot-Humid Production Builder  

Broader source: Energy.gov [DOE]

In this project, BSC worked with the builder to develop a cost-effective design for moving the HVAC system into conditioned space and increase the energy performance of future production houses in anticipation of 2015 IECC codes.

288

Building Technologies Office: Recovery Act-Funded HVAC Research Projects  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

HVAC Research Projects to someone by E-mail HVAC Research Projects to someone by E-mail Share Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Facebook Tweet about Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Twitter Bookmark Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Google Bookmark Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Delicious Rank Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Digg Find More places to share Building Technologies Office: Recovery Act-Funded HVAC Research Projects on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research Building Envelope Research Windows, Skylights, & Doors Research Space Heating & Cooling Research

289

Building Technologies Office: HVAC and Water Heater Field Tests Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

HVAC and Water Heater HVAC and Water Heater Field Tests Research Project to someone by E-mail Share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Facebook Tweet about Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Twitter Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Google Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Delicious Rank Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Digg Find More places to share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research

290

Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions for  

Broader source: Energy.gov (indexed) [DOE]

Critical Question #4: What are the Best Off-the-Shelf HVAC Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions for Low-Load, High-Performance Homes and Apartments? Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions for Low-Load, High-Performance Homes and Apartments? What is currently in the market? What are the limitations of these systems? What are the desired specifications for these systems? What are the realistic space conditioning loads of these high-performance homes and apartments? cq4_forced_air_systems_walker.pdf cq4_simplified_space_cond_prahl.pdf cq4_ground_heat_exchanger_im.pdf More Documents & Publications Track C - Market-Driven Research Solutions Track B - Critical Guidance for Peak Performance Homes Energy Storage & Power Electronics 2008 Peer Review - Power Electronics

291

Building America Best Practices Series Vol. 14: Energy Renovations - HVAC: A Guide for Contractors to Share with Homeowners  

Broader source: Energy.gov (indexed) [DOE]

HVAC HVAC A Guide for Contractors to Share with Homeowners PREPARED BY Pacific Northwest National Laboratory & Oak Ridge National Laboratory August 2011 August 2011 * PNNL-20421 BUILDING AMERICA BEST PRACTICES SERIES VOLUME 14. R BUILDING AMERICA BEST PRACTICES SERIES Energy Renovations Volume 14: HVAC A Guide for Contractors to Share with Homeowners Prepared by Pacific Northwest National Laboratory Program Manager: Michael C. Baechler Theresa L. Gilbride, Michael C. Baechler, Marye G. Hefty, and James R. Hand and Oak Ridge National Laboratory Pat M. Love August 2011 Prepared for the U.S. Department of Energy Building America Program PNNL-20421 Pacific Northwest National Laboratory Richland, Washington 99352 Contract DE-AC05-76RLO 1830 This report was prepared as an account of work sponsored by an agency of the

292

High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems  

Broader source: Energy.gov [DOE]

High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems presentation at the April 2013 peer review meeting held in Denver, Colorado.

293

Atmospheric Environment 41 (2007) 31513160 Ozone removal by HVAC filters  

E-Print Network [OSTI]

Atmospheric Environment 41 (2007) 3151­3160 Ozone removal by HVAC filters P. Zhao, J.A. Siegel�, R May 2006; accepted 14 June 2006 Abstract Residential and commercial HVAC filters that have been loaded of the relative importance of HVAC filters as a removal mechanism for ozone in residential and commercial

Siegel, Jeffrey

294

ThermoSense: Occupancy Thermal Based Sensing for HVAC Control  

E-Print Network [OSTI]

ThermoSense: Occupancy Thermal Based Sensing for HVAC Control Alex Beltran Elect. Eng. & Comp Occupancy Sensing, Thermal Sensing, HVAC Control 1. INTRODUCTION From 1980 to 2010, energy in the United, November 13-14 2013, Rome, Italy. Copyright 2013 ACM 978-1-4503-2431-1/13/11 ...$15.00. (HVAC) consumed 42

Cerpa, Alberto E.

295

Department of Mechanical Engineering Spring 2012 HVAC Filter Sensor -Global  

E-Print Network [OSTI]

PENNSTATE Department of Mechanical Engineering Spring 2012 HVAC Filter Sensor - Global Overview The purpose of this project is to develop a heating, ventilation, and air conditioning (HVAC) monitoring a residential, forced flow, multi-zone HVAC filter needs to be replaced, and then alerts the users

Demirel, Melik C.

296

SMUD's HVAC Programs Ravi Patel-Program Planning  

E-Print Network [OSTI]

1 SMUD's HVAC Programs 5-7-13 Ravi Patel- Program Planning Bruce Baccei- R&D #12;SMUD's Residential contractors trained and BPI certified ­ Majority were pushing only HVAC; now driving the HPP · Program encourages more HVAC replacements to occur through HPP ­ Move away from stand alone programs ­ Start

California at Davis, University of

297

An update on acoustics designs for HVAC (Engineering) K. Marriott  

E-Print Network [OSTI]

An update on acoustics designs for HVAC (Engineering) K. Marriott IOA, 29a Ashburton Road, Croydon and Air Conditioning (HVAC) engineer is to engineer ways for keeping these factors under control the HVAC engineer's environmental requirements while minimizing noise generated in the process considering

Paris-Sud XI, Université de

298

Monitoring-based HVAC Commissioning of an Existing Office  

E-Print Network [OSTI]

LBNL-5940E Monitoring-based HVAC Commissioning of an Existing Office Building for Energy Efficiency thereof or The Regents of the University of California. #12;1 Monitoring-based HVAC Commissioning@lbl.gov, Tel: 1-510-486-4921 Abstract The performance of Heating, Ventilation and Air Conditioning (HVAC

299

Handover Performance of HVAC Duct Based Indoor Wireless Networks  

E-Print Network [OSTI]

Handover Performance of HVAC Duct Based Indoor Wireless Networks A. E. Xhafa, P. Sonthikorn, and O in indoor wireless net- works (IWN) that use heating, ventilation, and air conditioning (HVAC) ducts.e., new call blocking and handover dropping probabilities, of an IWN that uses HVAC ducts are up to 6

Stancil, Daniel D.

300

Continued on next page A letter explaining the 2005 HVAC  

E-Print Network [OSTI]

Continued on next page A letter explaining the 2005 HVAC Change-out to consumers is available this bulletin, or downloaded from the 2005 HVAC Change out Information website at: www.energy.ca.gov/title24 duct sealing requirements for HVAC change-outs in existing homes become effective October 1, 2005

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Tematiche di ricerca Controllo di sistemi HVAC&R  

E-Print Network [OSTI]

Tematiche di ricerca Controllo di sistemi HVAC&R Controllo di processo per l'industria dei;Tematiche di ricerca Controllo di sistemi HVAC&R Controllo di processo per l'industria dei semiconduttori controllo di sistemi HVAC&R 2 Controllo di processo per l'industria dei semiconduttori 3 Problemi di

Schenato, Luca

302

Research & Development Roadmap: Emerging HVAC Technologies  

Broader source: Energy.gov [DOE]

The Research and Development (R&D) Roadmap for Emerging Heating, Ventilation, and Air-Conditioning (HVAC) Technologies provides recommendations to the Building Technologies Office (BTO) on R&D activities to pursue that will aid in achieving BTO’s energy savings goals.

303

INTEGRATED ENERGY SYSTEMS: PRODUCTIVITY & BUILDING SCIENCE  

E-Print Network [OSTI]

Integrated Design of Commercial Building Ceiling Systems Integrated Design of Residential Ducting & Air FlowINTEGRATED ENERGY SYSTEMS: PRODUCTIVITY & BUILDING SCIENCE Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design of Small Commercial HVAC Systems

304

University of North Carolina at Charlotte Design and Construction Manual Section 2, Division 23 HVAC  

E-Print Network [OSTI]

­ HVAC SECTION 2 DIVISION 23 HVAC #12;University of North Carolina at Charlotte Design and Construction Manual Section 2, Division 23 ­ HVAC DIVISION 23 - HVAC Note: This is a guide for Designers only 23 0510 - MECHANICAL GENERAL - HVAC PART 1 - GENERAL 1.1 MECHANICAL DESIGNER: A. Design

Xie,Jiang (Linda)

305

Pre-Commercial Demonstration of Cost-Effective Advanced HVAC Controls- 2014 BTO Peer Review  

Broader source: Energy.gov [DOE]

Presenter: Hayden Reeve, United Technologies Research Center Optimal control coordination of heating, ventilation, and air conditioning (HVAC) equipment can reduce energy by more than 20% over current building automation systems (BASs) but is not widely deployed due to challenges with complexity, scalability, and deployment.

306

IFC HVAC interface to EnergyPlus - A case of expanded interoperability for energy simulation  

SciTech Connect (OSTI)

Tedious manual input of data that define a building, its systems and its expected pattern of use and operating schedules for building energy performance simulation has in the past diverted time and resources from productive simulation runs. In addition to its previously released IFCtoIDF utility that semiautomates the import of building geometry, the new IFC HVAC interface to EnergyPlus (released at the end of 2003) makes it possible to import and export most of the data that define HVAC equipment and systems in a building directly from and to other IFC compatible software tools. This reduces the manual input of other data needed for successful simulation with EnergyPlus to a minimum. The main purpose of this new interface is to enable import of HVAC equipment and systems definitions, generated by other IFC compatible software tools (such as HVAC systems design tools) and data bases, into EnergyPlus, and to write such definitions contained in EnergyPlus input files to the original IFC files from which building geometry was extracted for the particular EnergyPlus input. In addition, this interface sets an example for developers of other software tools how to import and/or export data other than building geometry from and/or into EnergyPlus. This paper describes the necessary simplifications and shortcuts incorporated in this interface, its operating environment, interface architecture, and the basic conditions and methodology for its use with EnergyPlus.

Bazjanac, Vladimir; Maile, Tobias

2004-03-29T23:59:59.000Z

307

Department of Energy and Mineral Engineering Spring 2013 Solar Innovations -HVAC and Waste Stream Analysis  

E-Print Network [OSTI]

included providing accurate floor plans and improve the system for improvement in indoor air qualityPENNSTATE Department of Energy and Mineral Engineering Spring 2013 Solar Innovations - HVAC areas and indoor air quality is below satisfactory. The waste stream was to be analysed to assess

Demirel, Melik C.

308

This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)  

E-Print Network [OSTI]

to air source heat pump systems, ground source systems have not been so widely used. This may. INTRODUCTION Ground source heat pump systems have become increas- ingly popular for both residential tools. In ground source heat pump systems, heat is extracted from or rejected to the ground via either

Ghajar, Afshin J.

309

This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)  

E-Print Network [OSTI]

efficient than conventional air-to-air systems. In practice, ground-source heat pump systems have also.J. Rees, and C. Yavuzturk. 2000. Recent Developments in Ground Source Heat Pump System Design, Modelling A28, p.34. #12;Page 1 of 1 Recent Developments in Ground Source Heat Pump System Design, Modeling

310

Two-Nucleon Systems in a Finite Volume  

SciTech Connect (OSTI)

I present the formalism and methodology for determining the nucleon-nucleon scattering parameters from the finite volume spectra obtained from lattice quantum chromodynamics calculations. Using the recently derived energy quantization conditions and the experimentally determined scattering parameters, the bound state spectra for finite volume systems with overlap with the 3S1-3D3 channel are predicted for a range of volumes. It is shown that the extractions of the infinite-volume deuteron binding energy and the low-energy scattering parameters, including the S-D mixing angle, are possible from Lattice QCD calculations of two-nucleon systems with boosts of |P| <= 2pi sqrt{3}/L in volumes with spatial extents L satisfying fm <~ L <~ 14 fm.

Briceno, Raul

2014-11-01T23:59:59.000Z

311

Laboratory measurement of secondary pollutant yields from ozone reaction with HVAC filters.  

E-Print Network [OSTI]

Ozone Reaction with HVAC Filters Hugo Destaillats, WenhaoOzone Reaction with HVAC Filters Hugo Destaillats 1,3,* ,Ozone Reaction with HVAC Filters Hugo Destaillats 1,3,* ,

Destaillats, Hugo

2012-01-01T23:59:59.000Z

312

Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Radial Air Bearing Radial Air Bearing Heat Exchanger Research Project to someone by E-mail Share Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Facebook Tweet about Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Twitter Bookmark Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Google Bookmark Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Delicious Rank Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Digg Find More places to share Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE

313

Earth System Modelling - Volume 2: Algorithms, Code Infrastructure and Optimisation  

Science Journals Connector (OSTI)

Collected articles in this series are dedicated to the development and use of software for earth system modelling and aims at bridging the gap between IT solutions and climate science. The particular topic covered in this volume addresses the historical ...

Luca Bonaventura; Ren Redler; Reinhard Budich

2011-10-01T23:59:59.000Z

314

This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)  

E-Print Network [OSTI]

-term temperature response of the ground. Energy consumption for this system is compared to that of a conventional performance and long-term temperature response of the ground. Energy consumption for this system is compared system with condensing gas boilers and vapor compression refrigeration. Introduction Ground source heat

315

Air-Side Energy Use Calculations for Four HVAC Systems: Dual Duct Constant Volume (DDCAV), Dual Duct Variable Volume (DDVAV), Constant Volume with Reheat (CAVRH0), Variable Volume with Reheat (VAVRH)  

E-Print Network [OSTI]

.7 13.7 Next, calculate the ventilation air mass flow rate for Zone #2 using m2,min = CFMZMIN2 x 60 x 1/v m2,min= 1311.7 1312.8 moa,(zone#l+#2)=(ml,min + m2,min) moa,l+2= 2189.7 2191.5 Next, calculate the mass of the return air = mra = (ml+m2) NOTE: 7....7 13.7 Next, calculate the ventilation air mass flow rate for Zone #2 using m2,min = CFMZMIN2 x 60 x 1/v m2,min= 1311.7 1312.8 moa,(zone#l+#2)=(ml,min + m2,min) moa,l+2= 2189.7 2191.5 Next, calculate the mass of the return air = mra = (ml+m2) NOTE: 7...

Haberl, J. S.

2001-01-01T23:59:59.000Z

316

Can ASHRAE Standard 62-1989 Requirements be Satisfied while Maintaining Moisture Control using Stock HVAC Equipment in Hot, Humid Climates?  

E-Print Network [OSTI]

increase latent loads more than sensible loads, requiring lower sensible heat ratios. Stock HVAC package units and split systems are not available with the requisite sensible heat ratios, and cannot maintain moisture control in small commercial buildings...

Turner, S. C.

1996-01-01T23:59:59.000Z

317

Pedernales Electric Cooperative - HVAC Rebate Program | Department of  

Broader source: Energy.gov (indexed) [DOE]

Pedernales Electric Cooperative - HVAC Rebate Program Pedernales Electric Cooperative - HVAC Rebate Program Pedernales Electric Cooperative - HVAC Rebate Program < Back Eligibility Commercial Residential Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Program Info State Texas Program Type Utility Rebate Program Utility Rebate Program Rebate Amount Central AC with Gas Furnace: $300 - $400/unit Heat Pump: $400 - $500/unit Dual-Fuel Heat Pump: $400 - $500/unit Geothermal Heat Pump: $1,000/unit Water-Source Heat Pump: $1,000/unit Provider Pedernales Electric Cooperative Pedernales Electric Cooperative offers equipment rebates to members who install energy efficient HVAC equipment. Eligible equipment includes:

318

SIMULATION AND EXPERIMENTAL VALIDATION OF AIRBORNE AND STRUCTURE-BORNE NOISE TRANSMISSION IN HVAC PLENUMS.  

E-Print Network [OSTI]

??This research demonstrates the usage of numerical acoustics to model sound and vibrational energy propagation in HVAC ducts and plenums. Noise and vibration in HVAC… (more)

Ramalingam, Srinivasan

2012-01-01T23:59:59.000Z

319

This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)  

E-Print Network [OSTI]

trenches or vertical boreholes. The heat exchange fluid is usually water, brine, or an antifreeze solution and the soil/rock and prevents cross- contamination of groundwater. In nonresidential ground- coupled systems

320

High-Temperature-High-Volume Lifting For Enhanced Geothermal Systems  

Open Energy Info (EERE)

Temperature-High-Volume Lifting For Enhanced Geothermal Systems Temperature-High-Volume Lifting For Enhanced Geothermal Systems Geothermal Project Jump to: navigation, search Last modified on July 22, 2011. Project Title High-Temperature-High-Volume Lifting For Enhanced Geothermal Systems Project Type / Topic 1 Recovery Act: Enhanced Geothermal Systems Component Research and Development/Analysis Project Type / Topic 2 High-Temperature-High-Volume Lifting Project Description The proposed scope of work is divided into three Phases. Overall system requirements will be established in Phase 1, along with an evaluation of existing lifting system capability, identification of technology limitations, and a conceptual design of an overall lifting system. In developing the system components in Phase 2, component-level tests will be conducted using GE facilities. Areas of development will include high-temperature drive system materials, journal and thrust bearings, and corrosion and erosion-resistant lifting pump components. Finally, in Phase 3, the overall lab-scale lifting system will be demonstrated in a flow loop that will be constructed at GE Global Research.

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)  

E-Print Network [OSTI]

to eliminate or reduce dangerous driving conditions caused by snow and ice. The first important task in sizing of idling time, heating capacity, pipe spacing, bottom insulation, and control strategies on system snow through a pipe network embedded in the slab to melt snow and ice on the surface of the slab. The pipe

322

The new standard’s HVAC background noise requirements and their implementation in building design  

Science Journals Connector (OSTI)

The new ANSI classroom standard recommends long?term steady?state background sound level limits of 35 dBA and 55 dBC. Since the HVAC system is typically a room’s dominant steady?state noise source it is usually reasonable to apply these limits to the design of the system assuming that other noise sources produce insignificant additions to the room’s long?term background noise environment. The recommended sound level limits are significantly lower than current industry standards and complying with them will increase system costs. School administrators architects and HVAC system designers should therefore be prepared for the changes. This paper summarizes equipment selection and system design guidelines that have been found to be necessary for ensuring compliance with the sound level limits.

2001-01-01T23:59:59.000Z

323

Modeling the Earth System, volume 3  

SciTech Connect (OSTI)

The topics covered fall under the following headings: critical gaps in the Earth system conceptual framework; development needs for simplified models; and validating Earth system models and their subcomponents.

Ojima, D.

1992-01-01T23:59:59.000Z

324

Microsoft Word - HVAC_20100824.doc  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

air-handling units, exhaust fans, and HEPA filters and design specifications to allow for remote operation. The system design comprises approximately 70 drawings, which are...

325

Occupancy Based Demand Response HVAC Control Strategy Varick L. Erickson  

E-Print Network [OSTI]

Occupancy Based Demand Response HVAC Control Strategy Varick L. Erickson University of California an efficient demand response HVAC control strategy, actual room usage must be considered. Temperature and CO2 are used for simulations but not for predictive demand response strategies. In this paper, we develop

Cerpa, Alberto E.

326

Columbia Water and Light - HVAC and Lighting Efficiency Rebates |  

Broader source: Energy.gov (indexed) [DOE]

Columbia Water and Light - HVAC and Lighting Efficiency Rebates Columbia Water and Light - HVAC and Lighting Efficiency Rebates Columbia Water and Light - HVAC and Lighting Efficiency Rebates < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Lighting: 50% of invoiced cost up to $22,500 Program Info State Missouri Program Type Utility Rebate Program Rebate Amount HVAC Replacements: $570 - $3,770 Lighting: $300/kW reduction or half of project cost Provider Columbia Water and Light Columbia Water and Light (CWL) offers rebates to its commercial and industrial customers for the purchase of high efficiency HVAC installations and efficient lighting. Incentives for certain measures are based upon the

327

HVAC Right-Sizing Part 1: Calculating Loads  

Broader source: Energy.gov (indexed) [DOE]

Building America Building America Presented by: Mike Gestwick - National Renewable Energy Laboratory Arlan Burdick, Anthony Grisolia - IBACOS, a Building America Research Team HVAC Right-Sizing Part 1: Calculating Loads Thursday, April 28 11:00 a.m. - 12:00 p.m. Eastern Building Technologies Program Mike Gestwick michael.gestwick@nrel.gov Building America: Introduction April 28, 2011 Introduction to Building America * Reduce energy use in new and existing residential buildings * Promote building science and systems engineering / integration approach * "Do no harm": Ensure safety, health and durability are maintained or improved * Accelerate adoption of high performance technologies www.buildingamerica.gov 15 Industry Research Teams Habitat Cost Effective Energy Retrofit Program

328

VARIABLE SPEED INTEGRATED INTELLIGENT HVAC BLOWER  

SciTech Connect (OSTI)

This comprehensive topical report discusses the key findings in the development of an advanced blower for HVAC applications. The benefits of rearward inclined blades over that of traditional forward inclined blades is well documented, and several prototype wheels are demonstrated in various housings. A comparison of retrofitted blowers to that of three typical units from the industry is presented. The design and modification of the blower housing is addressed and the impact of size limitations on static efficiency is discussed. The roadmap to rearward-inclined wheel technology insertion is presented and typical static efficiency gains are documented.

Herman Wiegman; Charlie Stephens; Xiaoyue Liu; Ralph Carl; Sunny Zhuang; Paul Szczesny; Kamron Wright

2003-09-23T23:59:59.000Z

329

Evaluation of HVAC filters as a sampling mechanism for indoor microbial communities  

E-Print Network [OSTI]

Evaluation of HVAC filters as a sampling mechanism for indoor microbial communities Federico Noris Fungi Microbial community HVAC filter Settled dust Air a b s t r a c t HVAC filters are in place of bacterial and fungal concentrations and communities in HVAC filter dust and other sampling locations

Siegel, Jeffrey

330

Integrated safety management system verification: Volume 2  

SciTech Connect (OSTI)

Department of Energy (DOE) Policy (P) 450.4, Safety Management System Policy, commits to institutionalization of an Integrated Safety Management System (ISMS) throughout the DOE complex. The DOE Acquisition Regulations (DEAR, 48 CFR 970) requires contractors to manage and perform work in accordance with a documented Integrated Safety Management System (ISMS). Guidance and expectations have been provided to PNNL by incorporation into the operating contract (Contract DE-ACM-76FL0 1830) and by letter. The contract requires that the contractor submit a description of their ISMS for approval by DOE. PNNL submitted their proposed Safety Management System Description for approval on November 25,1997. RL tentatively approved acceptance of the description pursuant to a favorable recommendation from this review. The Integrated Safety Management System Verification is a review of the adequacy of the ISMS description in fulfilling the requirements of the DEAR and the DOE Policy. The purpose of this review is to provide the Richland Operations Office Manager with a recommendation for approval of the ISMS description of the Pacific Northwest Laboratory based upon compliance with the requirements of 49 CFR 970.5204(-2 and -78); and to verify the extent and maturity of ISMS implementation within the Laboratory. Further the review will provide a model for other DOE laboratories managed by the Office of Assistant Secretary for Energy Research.

Christensen, R.F.

1998-08-10T23:59:59.000Z

331

Wireless Demand Response Controls for HVAC Systems  

E-Print Network [OSTI]

all network nodes on AA batteries for years and still haveon a pair of AA lithium batteries. Assuming the worst caseper battery for two batteries, the annual cost of battery

Federspiel, Clifford

2010-01-01T23:59:59.000Z

332

MAPPING HVAC SYSTEMS FOR SIMULATION IN ENERGYPLUS  

E-Print Network [OSTI]

apps1.eere.energy.gov/buildings/energyplus/. Modelica, 2012.Modelica andthe Modelica Association — Modelica Association [WWW

Basarkar, Mangesh

2013-01-01T23:59:59.000Z

333

Measuring Advances in HVAC Distribution System Design  

E-Print Network [OSTI]

Energy Efficiency and Renewable Energy, Office of BuildingEnergy Efficiency and Renewable Energy, Office of Building

Franconi, E.

2011-01-01T23:59:59.000Z

334

Wireless Demand Response Controls for HVAC Systems  

E-Print Network [OSTI]

Strategies Linking Demand Response and Energy Efficiency,”Fully Automated Demand Response Tests in Large Facilities,technical support from the Demand Response Research Center (

Federspiel, Clifford

2010-01-01T23:59:59.000Z

335

Comparisons of HVAC Simulations between EnergyPlus and DOE-2.2 for Data Centers  

SciTech Connect (OSTI)

This paper compares HVAC simulations between EnergyPlus and DOE-2.2 for data centers. The HVAC systems studied in the paper are packaged direct expansion air-cooled single zone systems with and without air economizer. Four climate zones are chosen for the study - San Francisco, Miami, Chicago, and Phoenix. EnergyPlus version 2.1 and DOE-2.2 version 45 are used in the annual energy simulations. The annual cooling electric consumption calculated by EnergyPlus and DOE-2.2 are reasonablely matched within a range of -0.4percent to 8.6percent. The paper also discusses sources of differences beween EnergyPlus and DOE-2.2 runs including cooling coil algorithm, performance curves, and important energy model inputs.

Hong, Tianzhen; Sartor, Dale; Mathew, Paul; Yazdanian, Mehry

2008-08-13T23:59:59.000Z

336

Remote-handled transuranic system assessment appendices. Volume 2  

SciTech Connect (OSTI)

Volume 2 of this report contains six appendices to the report: Inventory and generation of remote-handled transuranic waste; Remote-handled transuranic waste site storage; Characterization of remote-handled transuranic waste; RH-TRU waste treatment alternatives system analysis; Packaging and transportation study; and Remote-handled transuranic waste disposal alternatives.

NONE

1995-11-01T23:59:59.000Z

337

Improved Air Volume Control Logic for VAV Systems  

E-Print Network [OSTI]

In a VAV (variable air volume) system, the set point of the static pressure (usually measured at 213 downstream of the main supply air duct) is maintained by modulating the fan speed or inlet guide vane position. The set point of the static pressure...

Wei, G.; Claridge, D. E.; Sakuri, Y.; M. Liu

2000-01-01T23:59:59.000Z

338

Demo Abstract: TOSS: Thermal Occupancy Sensing System  

E-Print Network [OSTI]

to a building's energy management system in order to control the Heating, Ventilation, Air Condition- ing, (HVAC, Measurement, Performance Keywords Occupancy sensing, Occupancy-based HVAC 1. INTRODUCTION To increase energy materials harnessing passive solar technologies along with increasingly efficient HVAC systems have

Cerpa, Alberto E.

339

Connexus Energy - Residential Efficient HVAC Rebate Program | Department of  

Broader source: Energy.gov (indexed) [DOE]

Connexus Energy - Residential Efficient HVAC Rebate Program Connexus Energy - Residential Efficient HVAC Rebate Program Connexus Energy - Residential Efficient HVAC Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Program Info Expiration Date 12/31/2013 State Minnesota Program Type Utility Rebate Program Rebate Amount Air Source Heat Pumps: $480 - $630 Ductless Heat Pump: $150 Geothermal Heat Pump: $200/ton Provider Connexus Energy Connexus Energy offers rebates for residential customers to improve the energy efficiency of homes. Rebates are available for air source heat pumps, ductless heat pumps and ground-source heat pumps. Equipment must meet all efficiency standards listed on the web site, and must be installed by a certified HVAC contractor. Contact Connexus Energy for other program

340

HVAC Cabinet Air Leakage Test Method- Building America Top Innovation  

Broader source: Energy.gov [DOE]

This 2014 Top Innovation describes Building America research that resulted in the development of an ASHRAE standard and standardized testing method for testing the air leakage of HVAC air handlers and furnace cabinets.

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics  

E-Print Network [OSTI]

Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate...

Graham, E. L.

1980-01-01T23:59:59.000Z

342

Study on Commissioning Process for Control Logic of Thermal Storage System  

E-Print Network [OSTI]

The Heating, Ventilation, and Air-Conditioning (HVAC) System Control Logic Tracer, or 'CLT' , can trace the control moves of an HVAC system and display it on a flowchart based on operation data collected in BEMS. Through comparison between estimates...

Shioya, M.; Tsubaki, M.; Nakahara, N.

2004-01-01T23:59:59.000Z

343

Reaerosolization of Fluidized Spores in Ventilation Systems  

Science Journals Connector (OSTI)

...high-efficiency particulate air filters were added to the air...and air conditioning (HVAC) systems. Particles...deposited on the walls of the HVAC test apparatus (Fig...reaerosolization under simulated HVAC operational conditions...particulate air (HEPA) filter cartridges were added...

Paula Krauter; Arthur Biermann

2007-02-09T23:59:59.000Z

344

Variable Speed Drive (VSD) Applications in Dual-Duct Constant Volume Systems  

E-Print Network [OSTI]

Models have been developed for static pressure and potential supply fan energy savings by using variable speed drive (VSD) in dual-duct constant volume systems. Experiments have been performed using a full size dual-duct constant volume system...

Joo, I.; Liu, M.; Conger, K.; Wang, G.

2002-01-01T23:59:59.000Z

345

Comfort by Design: An Introduction to HVAC's Variable Refrigerant Flow (VRF) Technology  

E-Print Network [OSTI]

Comfort by Design An Introduction to HVAC’s Variable Refrigerant Flow (VRF) Technology Keith Reihl kreihl@hvac.mea.com ESL-KT-14-11-13 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 HVAC Market Overview 0% 27% 9% 5% 4... Through Efficiency Conference, Dallas, Texas Nov. 18-20 How LOUD is a traditional HVAC unit? 33 dB(A) Library 50 dB(A) Refrigerator 60 dB(A) Conversation 78 dB(A) Vacuum 25 dB(A) Recording Studio 65-75 dB(A) Residential 3-ton HVAC Unit How Q IET are VRF...

Reihl,K.

2014-01-01T23:59:59.000Z

346

Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1  

E-Print Network [OSTI]

Imports/Exports Gas Availability Change efficiency choice equation Add technologiestoHVAC model Adjust cost-efficiency parameter Develop HVAC Conversion

Johnson, F.X.

2010-01-01T23:59:59.000Z

347

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review ...  

Energy Savers [EERE]

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review Presenter: Tony Bouza, U.S. Department of Energy This...

348

Building America Whole-House Solutions for New Homes: HVAC Design...  

Energy Savers [EERE]

HVAC Design Strategy for a Hot-Humid Production Builder Building America Whole-House Solutions for New Homes: HVAC Design Strategy for a Hot-Humid Production Builder In this...

349

CoolCab Thermal Load Reduction Project: CoolCalc HVAC Tool Development...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Thermal Load Reduction Project: CoolCalc HVAC Tool Development CoolCab Thermal Load Reduction Project: CoolCalc HVAC Tool Development 2010 DOE Vehicle Technologies and Hydrogen...

350

Uncertainties in Achieving Energy Savings from HVAC Maintenance Measures in the Field  

E-Print Network [OSTI]

Uncertainties in Achieving Energy Savings from HVAC Maintenance Measures in the Field Kristin utilities across the nation to include HVAC maintenance measures in energy efficiency programs Maintenance measures have a significant potential for energy savings in residential and commercial unitary

California at Davis, University of

351

Issue #3: HVAC Proper Installation Energy Savings: Over-Promising or Under-Delivering?  

Office of Energy Efficiency and Renewable Energy (EERE)

What energy savings are realistically achievable by following quality installation standards for installation, operation, and maintenance of residential HVAC?

352

Evaluation of flow capture techniques for measuring HVAC grilleairflows  

SciTech Connect (OSTI)

This paper discusses the accuracy of commercially available flow hoods for residential applications. Results of laboratory and field tests indicate these hoods can be inadequate to measure airflows in residential systems, and there can be large measurement discrepancies between different flow hoods. The errors are due to poor calibrations, sensitivity of the hoods to grille airflow non-uniformities, and flow changes from added flow resistance. It is possible to obtain reasonable results using some flow hoods if the field tests are carefully done, the grilles are appropriate, and grille location does not restrict flow hood placement. We also evaluated several simple flow capture techniques for measuring grille airflows that could be adopted by the HVAC industry and homeowners as simple diagnostics. These simple techniques can be as accurate as commercially available devices. Our test results also show that current calibration procedures for flow hoods do not account for field application problems. As a result, agencies such as ASHRAE or ASTM need to develop a new standard for flow hood calibration, along with a new measurement standard to address field use of flow capture techniques.

Walker, Iain S.; Wray, Craig P.

2002-11-01T23:59:59.000Z

353

Deposition of biological aerosols on HVAC heat exchangers  

SciTech Connect (OSTI)

Many biologically active materials are transported as bioaerosols 1-10 {micro}m in diameter. These particles can deposit on cooling and heating coils and lead to serious indoor air quality problems. This paper investigates several of the mechanisms that lead to aerosol deposition on fin and tube heat exchangers. A model has been developed that incorporates the effects of several deposition mechanisms, including impaction, Brownian and turbulent diffusion, turbophoresis, thermophoresis, diffusiophoresis, and gravitational settling. The model is applied to a typical range of air velocities that are found in commercial and residential HVAC systems 1 - 6 m/s (200 - 1200 ft/min), particle diameters from 1 - 8 {micro}m, and fin spacings from 3.2 - 7.9 fins/cm (8 - 16 fins/inch or FPI). The results from the model are compared to results from an experimental apparatus that directly measures deposition on a 4.7 fins/cm (12 FPI) coil. The model agrees reasonably well with this measured data and suggests that cooling coils are an important sink for biological aerosols and consequently a potential source of indoor air quality problems.

Siegel, Jeffrey; Walker, Ian

2001-09-01T23:59:59.000Z

354

Theoretical Estimates of HVAC Duct Channel Capacity for High-Speed Internet Access  

E-Print Network [OSTI]

Theoretical Estimates of HVAC Duct Channel Capacity for High-Speed Internet Access Ariton E. Xhafa-conditioning (HVAC) ducts based on multi-carrier transmission that uses M-QAM mod- ulation and measured channel- flections in HVAC ducts). Our work also shows that data rates in excess of 300 Mbps are possible over

Stancil, Daniel D.

355

Comparison of HVAC filter test methods for particle removal efficiency Brent Stephens1,*  

E-Print Network [OSTI]

Comparison of HVAC filter test methods for particle removal efficiency Brent Stephens1,* , Jeffrey Introduction The use of HVAC filters in buildings is one strategy to reduce occupant exposure to particulate matter. However, HVAC filters are typically tested only in laboratory settings and little is known about

Siegel, Jeffrey

356

Comparison of dust from HVAC filters, indoor surfaces, and indoor air Federico Noris*  

E-Print Network [OSTI]

Comparison of dust from HVAC filters, indoor surfaces, and indoor air Federico Noris* , Kerry A and Environmental Engineering * Corresponding email: Fedenoris@mail.utexas.edu SUMMARY HVAC filters are long heavy metal (Pb, Cd and As) concentrations. HVAC filter microbial concentrations appear to be consistent

Siegel, Jeffrey

357

Self-Correcting HVAC Controls: Algorithms for Sensors and Dampers in Air-Handling Units  

SciTech Connect (OSTI)

This report documents the self-correction algorithms developed in the Self-Correcting Heating, Ventilating and Air-Conditioning (HVAC) Controls project funded jointly by the Bonneville Power Administration and the Building Technologies Program of the U.S. Department of Energy. The algorithms address faults for temperature sensors, humidity sensors, and dampers in air-handling units and correction of persistent manual overrides of automated control systems. All faults considered create energy waste when left uncorrected as is frequently the case in actual systems.

Fernandez, Nicholas; Brambley, Michael R.; Katipamula, Srinivas

2009-12-31T23:59:59.000Z

358

Entropy Production : From Open Volume Preserving to Dissipative Systems  

E-Print Network [OSTI]

We generalize Gaspard's method for computing the \\epsilon-entropy production rate in Hamiltonian systems to dissipative systems with attractors considered earlier by T\\'el, Vollmer, and Breymann. This approach leads to a natural definition of a coarse grained Gibbs entropy which is extensive, and which can be expressed in terms of the SRB measures and volumes of the coarse graining sets which cover the attractor. One can also study the entropy and entropy production as functions of the degree of resolution of the coarse graining process, and examine the limit as the coarse graining size approaches zero. We show that this definition of the Gibbs entropy leads to a positive rate of irreversible entropy production for reversible dissipative systems. We apply the method to the case of a two dimensional map, based upon a model considered by Vollmer, T\\'el and Breymann, that is a deterministic version of a biased-random walk. We treat both volume preserving and dissipative versions of the basic map, and make a comparison between the two cases. We discuss the \\epsilon-entropy production rate as a function of the size of the coarse graining cells for these biased-random walks and, for an open system with flux boundary conditions, show regions of exponential growth and decay of the rate of entropy production as the size of the cells decreases. This work describes in some detail the relation between the results of Gaspard, those of T\\'el, Vollmer and Breymann, and those of Ruelle, on entropy production in various systems described by Anosov or Anosov-like maps.

T. Gilbert; J. R. Dorfman

1999-03-11T23:59:59.000Z

359

Optimized HVAC Management Service to Enhance Demand Response  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Optimized HVAC Management Service to Enhance Demand Response Optimized HVAC Management Service to Enhance Demand Response Speaker(s): John Steinberg Date: August 18, 2011 - 12:00pm Location: 90-4133 Seminar Host/Point of Contact: Janie Page Many utilities are investing vast sums deploying smart meters to customers, some of whom remain stubbornly opposed to those deployments, in large part because they remain unmoved by the claimed benefits. EcoFactor has developed a thermostat management service that delivers (and quantifies) significant energy savings for consumers and a number of additional benefits to other players in the energy value chain. It does so without relying on consumers to modify behavior, study energy information displays, or even pay attention to their energy use. EcoFactor also significantly boosts DR yield while it increases occupant comfort. It can identify HVAC

360

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency  

Broader source: Energy.gov (indexed) [DOE]

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives < Back Eligibility Commercial Industrial Multi-Family Residential Nonprofit Savings Category Other Heating & Cooling Commercial Heating & Cooling Cooling Home Weatherization Construction Commercial Weatherization Design & Remodeling Manufacturing Sealing Your Home Ventilation Heat Pumps Heating Appliances & Electronics Commercial Lighting Lighting Water Heating Maximum Rebate $600,000/year/facility. Incentives $1-$200,000: paid at 100% Incentives $200,000-$600,000: paid at 50% Custom: 50% of incremental cost Retro-Commissioning: $200,000/year/facility; $100,000/project Leak Survey: $10,000

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Approved Module Information for EE3PSY, 2014/5 Module Title/Name: Power Systems 6 Module Code: EE3PSY  

E-Print Network [OSTI]

HVDC and HVAC. The work also covers several case studies on system collapse based in the UK, EU and USA

Neirotti, Juan Pablo

362

Approved Module Information for EE4PSY, 2014/5 Module Title/Name: Power Systems 6 Module Code: EE4PSY  

E-Print Network [OSTI]

HVDC and HVAC. The work also covers several case studies on system collapse based in the UK, EU and USA

Neirotti, Juan Pablo

363

Report on HVAC option selections for a relocatable classroom energy and indoor environmental quality field study  

SciTech Connect (OSTI)

It is commonly assumed that efforts to simultaneously develop energy efficient building technologies and to improve indoor environmental quality (IEQ) are unfeasible. The primary reason for this is that IEQ improvements often require additional ventilation that is costly from an energy standpoint. It is currently thought that health and productivity in work and learning environments requires adequate, if not superior, IEQ. Despite common assumptions, opportunities do exist to design building systems that provide improvements in both energy efficiency and IEQ. This report outlines the selection of a heating, ventilation, and air conditioning (HVAC) system to be used in demonstrating such an opportunity in a field study using relocatable school classrooms. Standard classrooms use a common wall mounted heat pump HVAC system. After reviewing alternative systems, a wall-mounting indirect/direct evaporative cooling system with an integral hydronic gas heating is selected. The anticipated advantages of this system include continuous ventilation of 100 percent outside air at or above minimum standards, projected cooling energy reductions of about 70 percent, inexpensive gas heating, improved airborne particle filtration, and reduced peak load electricity use. Potential disadvantages include restricted climate regions and possible increases in indoor relative humidity levels under some conditions.

Apte, Michael G.; Delp, Woody W.; Diamond, Richard C.; Hodgson, Alfred T.; Kumar, Satish; Rainer, Leo I.; Shendell, Derek G.; Sullivan, Doug P.; Fisk, William J.

2001-10-11T23:59:59.000Z

364

Preliminary Systems Design Study assessment report. Volume 8, Appendixes  

SciTech Connect (OSTI)

The System Design Study (SDS), part of the Waste Technology Development Department at the Idaho National Engineering Laboratory (INEL), examined techniques available for the remediation of hazardous and transuranic waste stored at the Radioactive Waste Management Complex`s Subsurface Disposal Area at the INEL. Using specific technologies, system concepts for treating the buried waste and the surrounding contaminated soil were evaluated. Evaluation included implementability, effectiveness, and cost. The SDS resulted in the development of technology requirements including demonstration, testing, and evaluation activities needed for implementing each concept. This volume of the Systems Design Study contain four Appendixes that were part of the study. Appendix A is an EG&G Idaho, Inc., report that represents a review and compilation of previous reports describing the wastes and quantities disposed in the Subsurface Disposal Area of the Idaho National Engineering Laboratory. Appendix B contains the process flowsheets considered in this study, but not selected for detailed analysis. Appendix C is a historical tabulation of radioactive waste incinerators. Appendix D lists Department of Energy facilities where cementation stabilization systems have been used.

Mayberry, J.L.; Feizollahi, F.; Del Signore, J.C.

1992-01-01T23:59:59.000Z

365

Columbia River System Operation Review : Final Environmental Impact Statement, Appendix T (Second Continued Volume): Comments & Responses.  

SciTech Connect (OSTI)

This is Appendix T (second continued volume) giving public comments and responses to the final environmental impact statement for the Columbia River System.

Columbia River System Operation Review (U.S.)

1995-11-01T23:59:59.000Z

366

Phase transition in compressible Ising systems at fixed volume Akira Onuki and Akihiko Minami  

E-Print Network [OSTI]

Phase transition in compressible Ising systems at fixed volume Akira Onuki and Akihiko Minami transition behavior of compressible Ising systems at constant volume by varying the temperature. Simulations have been performed on compressible Ising systems and a number of numerical results still remain

367

Use of EMCS Recorded Data to Identify Potential Savings Due to Improved HVAC Operations & Maintenance (O&M)  

E-Print Network [OSTI]

Use of EMCS Recorded Data to Identify Potential Savings Due to Improved HVAC Operations & Maintenance(O&M) Mingsheng Liu, Yeqiao Zhu, and David Claridge Energy Systems Laboratory Texas A&M University ABSTRACT In most chiller and boiler central... and cooling energy consumption using an appropriate model [Liu 1995, Liu and Claridge 19951 with the bin weather data for each building. Step 5: Calculate the campus consumption as the sum of consumption of all buildings. Step 6: Compare the simulated...

Liu, M.; Zhu, Y.; Claridge, D. E.

1996-01-01T23:59:59.000Z

368

BULGARIAN ACADEMY OF SCIENCES CYBERNETICS AND INFORMATION TECHNOLOGIES Volume 7, No 1  

E-Print Network [OSTI]

, electrical heating, co-generation (gas turbine, diesels). To integrate subsystems with various functions by developing Java-based software according FIPA specifications. Simulation results for simplified HVAC system HVAC systems [2, 18, 19, 21, 30, 37] give promising results overcome some emergent problems: To develop

Borissova, Daniela

369

HVAC Design Strategy for a Hot-Humid Production Builder, Houston, Texas (Fact Sheet)  

SciTech Connect (OSTI)

BSC worked directly with the David Weekley Homes - Houston division to redesign three floor plans in order to locate the HVAC system in conditioned space. The purpose of this project is to develop a cost effective design for moving the HVAC system into conditioned space. In addition, BSC conducted energy analysis to calculate the most economical strategy for increasing the energy performance of future production houses. This is in preparation for the upcoming code changes in 2015. The builder wishes to develop an upgrade package that will allow for a seamless transition to the new code mandate. The following research questions were addressed by this research project: 1. What is the most cost effective, best performing and most easily replicable method of locating ducts inside conditioned space for a hot-humid production home builder that constructs one and two story single family detached residences? 2. What is a cost effective and practical method of achieving 50% source energy savings vs. the 2006 International Energy Conservation Code for a hot-humid production builder? 3. How accurate are the pre-construction whole house cost estimates compared to confirmed post construction actual cost? BSC and the builder developed a duct design strategy that employs a system of dropped ceilings and attic coffers for moving the ductwork from the vented attic to conditioned space. The furnace has been moved to either a mechanical closet in the conditioned living space or a coffered space in the attic.

Not Available

2014-03-01T23:59:59.000Z

370

PRODIAG: Combined expert system/neural network for process fault diagnosis. Volume 2, Code manual  

SciTech Connect (OSTI)

We recommend the reader first review Volume 1 of this document, Code Theory, before reading Volume 2. In this volume we make extensive use of terms and concepts described and defined in Volume 1 which are not redefined here to the same extent. To try to reduce the amount of redundant information, we have restricted this volume to the presentation of the expert system code and refer back to the theory described in Volume 1 when necessary. Verification and validation of the results are presented in Volume 3, Application, of this document. Volume 3 also presents the implementation of the component characteristics diagnostic approach through artificial neural networks discussed in Volume 1. We decided to present the component characteristics approach in Volume 3, as opposed to write a separate code manual for it, because the approach, although general, requires a case-by-case analysis. The purpose of this volume is to present the details of the expert system (ES) portion o the PRODIAG process diagnostic program. In addition, we present here the graphical diagnostics interface (GDI) and illustrate the combined use of the ES and GDI with a sample problem. For completeness, we provide the file names of all files, programs and major subroutines of these two systems, ES and GDI, and their corresponding location in the Reactor Analysis Division (RA) computer network and Reactor Engineering Division (RE) computer network as of 30 September 1995.

Reifman, J.; Wei, T.Y.C.

1995-09-01T23:59:59.000Z

371

System 80+{trademark} Standard Design: CESSAR design certification. Volume 3: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report - Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These documents describe the Combustion Engineering, Inc. System 80+{sup TM} Standard Design. This report, Volume 3, in conjunction with Volume 2, provides the design of structures, components, equipment and systems.

Not Available

1990-12-21T23:59:59.000Z

372

System 80+{trademark} Standard Design: CESSAR design certification. Volume 2: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report - Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These documents describe the Combustion Engineering, Inc. System 80+{sup TM} Standard Design. This report, Volume 2, in conjunction with Volume 3, provides the design of structures, components, equipment and systems.

Not Available

1990-12-21T23:59:59.000Z

373

State energy price system. Volume I: overview and technical documentation  

SciTech Connect (OSTI)

This study utilizes existing data sources and previous analyses of state-level energy prices to develop consistent state-level energy prices series by fuel type and by end-use sector. The fuels are electricity, natural gas, coal, distillate fuel oil, motor gasoline, diesel, kerosene, jet fuel, residual fuel, and liquefied petroleum gas. The end-use sectors are residential, commercial, industrial, transportation, and electric utility. Based upon an evaluation of existing data sources, recommendations were formulated on the feasible approaches for developing a consistent state energy price series. The data series were compiled based upon the approaches approved after a formal EIA review. Detailed documentation was provided, including annual updating procedures. Recommendations were formulated for future improvements in the collection of data or in data processing. Generally, the geographical coverage includes the 50 states and the District of Columbia. Information on state-level energy use was generally taken from the State Energy Data System (SEDS). Corresponding average US prices are also developed using volumes reported in SEDS. To the extent possible, the prices developed are quantity weighted average retail prices. Both a Btu price series and a physical unit price series are developed for each fuel. The period covered by the data series is 1970 through 1980 for most fuels, though prices for electricity and natural gas extend back to 1960. (PSB)

Fang, J.M.; Nieves, L.A.; Sherman, K.L.; Hood, L.J.

1982-06-01T23:59:59.000Z

374

Environmental control principles - A textbook supplement to the ASHRAE handbook 1985 fundamentals volume and the companion solutions manual to environmental control principles  

SciTech Connect (OSTI)

This book reviews HVAC General Concepts, Systems Equipment and challenges the reader to provide solutions for the Problems and Examples section.

Not Available

1985-01-01T23:59:59.000Z

375

Two Alabama Elementary Schools Get Cool with New HVAC Units | Department of  

Broader source: Energy.gov (indexed) [DOE]

Alabama Elementary Schools Get Cool with New HVAC Units Alabama Elementary Schools Get Cool with New HVAC Units Two Alabama Elementary Schools Get Cool with New HVAC Units October 1, 2010 - 2:05pm Addthis Winston County School District will receive 14 new HVAC units with State Energy Program funding. | File photo Winston County School District will receive 14 new HVAC units with State Energy Program funding. | File photo Lindsay Gsell What are the key facts? Two public elementary schools receive 14 new HVAC units for classrooms. School district estimates nearly 10 percent in electrical savings with new units. Nineteen Alabama public school districts using Recovery Act grants to save energy and money. Addison Elementary School and Double Springs Elementary School in northwestern Alabama were warm. Some classrooms just didn't cool fast enough. The buildings, which were

376

CHARACTERIZATION OF AIRFLOWS NEAR THE EXIT OF HVAC REGISTERS USING LASER DOPPLER VELOCIMETRY (LDV).  

SciTech Connect (OSTI)

A facility to characterize the airflow at the exit of HVAC registers was designed and fabricated. The objective of this work is to obtain velocity and turbulence data at the exit of registers, which can then be used as an input boundary condition in a modern Computational Fluid Dynamics (CFD) code to predict the velocity and temperature distribution in an enclosure, and also the register performance parameters such as throw. During the course of this work, two commonly used registers were tested. Both registers were 8 inch x 4 inch sidewall registers. Laser Doppler Velocimetry was used to measure the axial and vertical components of the velocity vector at various locations across the face of the registers. For the two cases of registers studied here, the results suggest that the velocity field at the very exit of each of these registers scales with the flow rate through the registers. This means that, in the mode of operation in which the supply fan (of an HVAC system) has a ''High'' and ''Low'' setting, similar velocity scaling would result for the type of registers tested here.

TUTU,N.K.; KRISHNA,C.R.; ANDREWS,J.W.; BUTCHER,T.A.

2003-03-13T23:59:59.000Z

377

HVAC Radial Air Bearing Heat Exchangers Research Project | Department of  

Broader source: Energy.gov (indexed) [DOE]

Radial Air Bearing Heat Exchangers Radial Air Bearing Heat Exchangers Research Project HVAC Radial Air Bearing Heat Exchangers Research Project The U.S. Department of Energy is currently conducting research into heating, ventilation, and air conditioning (HVAC) radial air bearing heat exchangers. Rotary air bearing heat exchanger technology simultaneously solves four long standing problems of conventional "fan-plus-finned-heat-sink" heat exchangers. Project Description This project seeks to design, fabricate, and test successive generations of prototype radial air bearing heat exchanger devices based on lessons learned and further insights into device optimization, computational fluid dynamic studies for parametric optimization and determination of scaling laws, and laboratory measurement of flow field and heat transfer

378

DOE Zero Energy Ready Home Low Load High Efficiency HVAC Webinar (Text Version)  

Broader source: Energy.gov [DOE]

Below is the text version of the DOE Zero Energy Ready Home webinar, Low Load High Efficiency HVAC, presented in May 2014.

379

Characterization of the HVAC performance with defroster grillers and instrument panel registers  

Science Journals Connector (OSTI)

Improving HVAC performance is of paramount importance to sustain ... was between 15 to 25 degrees with a standard distance ratio of one. During the cooling...

M. F. Kader; Y. M. Youn; Y. D. Jun…

2009-06-01T23:59:59.000Z

380

Numerical Investigation of Flow Induced Noise in a Simplified HVAC Duct with OpenFOAM.  

E-Print Network [OSTI]

?? Due to the growing demand for comfort, the noise generated by HVAC components should be considered by the designers. Flow induced noise is one… (more)

Wang, Cong

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Active Integrated Perimeter Building Systems | Department of...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

sensor data, but sharing the data with faade and HVAC control systems to implement load reduction or demand-side ventilation strategies is difficult because the data are...

382

System 80+{trademark} Standard Design: CESSAR design certification. Volume 11: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80{sup +}{trademark} Standard Design. This volume 11 discusses Radiation Protection, Conduct of Operations, and the Initial Test Program.

Not Available

1990-12-21T23:59:59.000Z

383

System 80+{trademark} Standard Design: CESSAR design certification. Volume 17: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describes the Combustion Engineering, Inc. System 80+{trademark} Standard Design. This Volume 17 provides Appendix A of this report, closure of unresolved and Genetic Safety Issues.

Not Available

1990-12-21T23:59:59.000Z

384

System 80+{trademark} Standard Design: CESSAR design certification. Volume 1: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report - Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These Volumes, describe the Combustion Engineering, Inc. System 80+{sup TM} Standard Design. This document, Volume 1, provides an introduction and general description of plant and site envelope characteristics.

Not Available

1990-12-21T23:59:59.000Z

385

System 80+{trademark} Standard Design: CESSAR design certification. Volume 8: Amendment I  

SciTech Connect (OSTI)

This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80{sup +}{trademark} Standard Design. This volume 8 provides a description of instrumentation and controls.

Not Available

1990-12-21T23:59:59.000Z

386

System-Level Monitoring and Diagnosis of Building HVAC System  

E-Print Network [OSTI]

695. [50] M. Wetter, Modelica-based modelling and simulationhave been working on Modelica and EnergyPlus simulation59], DOE-2, TRANSYS, Modelica [50], etc. make use of the

Wu, Siyu

2013-01-01T23:59:59.000Z

387

Optimization of Ice Thermal Storage Systems Design for HVAC Systems  

E-Print Network [OSTI]

Ice thermal storage is promising technology to reduce energy costs by shifting the cooling cost from on-peak to off-peak periods. The paper discusses the optimal design of ice thermal storage and its impact on energy consumption, demand, and total...

Nassif, N.; Hall, C.; Freelnad, D.

2013-01-01T23:59:59.000Z

388

Proceedings of Healthy Buildings 2009 Paper 535 HVAC filters as "passive" samplers: fate analysis of indoor particles  

E-Print Network [OSTI]

Proceedings of Healthy Buildings 2009 Paper 535 HVAC filters as "passive" samplers: fate analysis the effectiveness of using HVAC filters as an indoor sampling technique. #12;Proceedings of Healthy Buildings 2009

Siegel, Jeffrey

389

Renewable Electricity Futures Study. Volume 4: Bulk Electric Power Systems: Operations and Transmission Planning  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Bulk Electric Power Systems: Bulk Electric Power Systems: Operations and Transmission Planning Volume 4 of 4 Volume 2 PDF Volume 3 PDF Volume 1 PDF Volume 4 PDF NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Renewable Electricity Futures Study Edited By Hand, M.M. National Renewable Energy Laboratory Baldwin, S. U.S. Department of Energy DeMeo, E. Renewable Energy Consulting Services, Inc. Reilly, J.M. Massachusetts Institute of Technology Mai, T. National Renewable Energy Laboratory Arent, D. Joint Institute for Strategic Energy Analysis Porro, G. National Renewable Energy Laboratory Meshek, M. National Renewable Energy Laboratory Sandor, D. National Renewable

390

HVAC, Water Heating, and Appliance Publications | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

to identify opportunities to reduce the energy consumption of electric motor-driven systems in the residential and commercial sectors through the use of advanced motor...

391

Impact of the Variable Refrigerant Volume Air Conditioning System on Building Energy Efficiency  

E-Print Network [OSTI]

The application of the variable refrigerant volume multi-zone air conditioning systems has met with mixed results since the publication of the Design Standard for Energy Efficiency of Public Buildings. This paper analyzes the characteristics...

Zhu, H.

2006-01-01T23:59:59.000Z

392

Two-particle multichannel systems in a finite volume with arbitrary spin  

SciTech Connect (OSTI)

The quantization condition for two-particle systems with arbitrary number of two-body open coupled channels, spin and masses in a finite cubic volume with either periodic or twisted boundary conditions is presented. The condition presented is in agreement with all previous studies of two-body systems in a finite volume. The result is relativistic, holds for all momenta below the three- and four-particle thresholds, and is exact up to exponential volume corrections that are governed by L/r, where L is the spatial extent of the volume and r is the range of the interactions between the particles. For hadronic systems the range of the interaction is set by the inverse of the pion mass, m?, and as a result the formalism presented is suitable for m?L>>1. Implications of the formalism for the studies of multichannel baryon-baryon systems are discussed.

Briceno, Raul A. [JLAB

2014-04-01T23:59:59.000Z

393

HVAC Component Data Modeling Using Industry Foundation Classes Vladimir Bazjanac, Lawrence Berkeley National Laboratory, U.S.A.  

E-Print Network [OSTI]

1 HVAC Component Data Modeling Using Industry Foundation Classes Vladimir Bazjanac, Lawrence. This paper describes a number of aspects of a major extension of the HVAC part of the IFC data model. First is the introduction of a more generic approach for handling HVAC components. This includes type information, which

394

1736 IEEE TRANSACTIONS ON COMMUNICATIONS, VOL. 51, NO. 10, OCTOBER 2003 Impulse Response of the HVAC Duct as a  

E-Print Network [OSTI]

of the HVAC Duct as a Communication Channel Pavel V. Nikitin, Member, IEEE, Daniel D. Stancil, Senior Member (HVAC) ducts in buildings behave as multimode waveguides when excited at radio frequencies and thus, can of a usual indoor propagation channel. In this paper, we describe physical mechanisms which affect the HVAC

Hochberg, Michael

395

IEEE TRANSACTIONS ON COMMUNICATIONS, VOL. 53, NO. 2, FEBRUARY 2005 335 On the Capacity Limits of HVAC Duct Channel for  

E-Print Network [OSTI]

of HVAC Duct Channel for High-Speed Internet Access Ariton E. Xhafa, Member, IEEE, Ozan K. Tonguz, Member and experimental channel-capacity estimates of heating, ventilation, and air condi- tioning (HVAC) ducts based suppressed. Our experimental results also show that even in the case of more complex HVAC duct networks (i

Stancil, Daniel D.

396

HVAC filter bypass modelling and experimental validation Jeffrey A. Siegel1,*  

E-Print Network [OSTI]

standards that address HVAC filtration efficacy including ASHRAE Standard 52.2 (ASHRAE, 2007) and EN 779HVAC filter bypass modelling and experimental validation Jeffrey A. Siegel1,* , David B. Chojnowski of filter bypass, an ASHRAE Standard 52.2-2007 compliant apparatus was modified to accept filters

Siegel, Jeffrey

397

Strategy Guideline: Compact Air Distribution Systems  

SciTech Connect (OSTI)

This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

Burdick, A.

2013-06-01T23:59:59.000Z

398

Source attenuating HVAC equipment—Just the facts  

Science Journals Connector (OSTI)

Current classroom designs range from NC 63 to NC 25. The ASA/ANSI 12.60 Classroom Standard sets a relatively low background sound requirement for classrooms. Achieving 12.60 levels economically requires the maximum in source sound attenuation. This paper will provide a manufacturer’s perspective on current and low noiseHVAC products and the resulting classroomsound levels. Predictive acoustics software will be used to predict the space sound power level and some indication of equipment cost will be provided in order to assist designers in what is the best approach to low noiseclassroom design.

2004-01-01T23:59:59.000Z

399

Decomposition of formaldehyde by EPD photocatalyst filters in HVAC  

Science Journals Connector (OSTI)

This study used electrophoretic deposition (EPD) to apply titanium oxide (TiO2) coating on stainless steel filters and investigated the effectiveness of photocatalytic oxidation of formaldehyde by TiO2 under various conditions of heating ventilation air conditioning (HVAC). The results showed photocatalytic efficiency could reach 35.59% at 21 °C and 36.39% at 26 °C with 7 photocatalyst filters and 5 UVC lamps, the overall efficiency of formaldehyde removal of 52.37% at 21 °C, and 56.8% at 26 °C. By all experimental data can be found that the temperature for the photocatalytic performance is not obvious in the range of this study.

Chien-Chih Chen; Ching-Song Jwo; Tun-Ping Teng

2011-01-01T23:59:59.000Z

400

Building America Webinar: High Performance Space Conditioning Systems, Part II  

Broader source: Energy.gov [DOE]

The webinar on Nov. 18, 2014, continued the series on strategies to improve the performance of HVAC systems for low load homes and home performance retrofits.

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Building America Webinar: High Performance Space Conditioning Systems, Part I  

Broader source: Energy.gov [DOE]

The webinar on Oct. 23, 2014 focused on strategies to improve the performance of HVAC systems for low load homes and home performance retrofits.

402

Applications of Optimal Building Energy System Selection and Operation  

E-Print Network [OSTI]

as a Service ST: solar thermal SVOW: Storage Viability WebPerformance of a Solar-Thermal-Assisted HVAC System,” Energyscheduling, PV, solar thermal, batteries INTRODUCTION

Marnay, Chris

2014-01-01T23:59:59.000Z

403

Buildings Energy Data Book: 5.5 Thermal Distribution Systems  

Buildings Energy Data Book [EERE]

HVAC Equipment Manufacturers (2009 Million) Air-Handling Units 1032 Cooling Towers 533 Pumps 333 Central System Terminal Boxes 192 Classroom Unit Ventilator 160 Fan Coil Units 123...

404

Grundfos HVAC OEM Efficient water hydraulics  

E-Print Network [OSTI]

Compact Hydro Block for Heat Pumps Hydraulic solution for small Heat Pump Systems p condensor Heating Future opportunities for heat pumps Grundfos Compact Hydro block Composite Design for Heat Pumps hydraulics Available today: Compact Hydro Block for integration High degree of pre-design Most important

Oak Ridge National Laboratory

405

Assessment of effectiveness of geologic isolation systems. CIRMIS data system. Volume 3. Generator routines  

SciTech Connect (OSTI)

The Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program is developing and applying the methodology for assessing the far-field, long-term post-closure safety of deep geologic nuclear waste repositories. AEGIS is being performed by Pacific Northwest Laboratory (PNL) under contract with the Office of Nuclear Waste Isolation (ONWI) for the Department of Energy (DOE). One task within AEGIS is the development of methodology for analysis of the consequences (water pathway) from loss of repository containment as defined by various release scenarios. The various input parameters required in the analysis are compiled in data systems. The data are organized and prepared by various input subroutines for utilization by the hydraulic and transport codes. The hydrologic models simulate the groundwater flow systems and provide water flow directions, rates, and velocities as inputs to the transport models. Outputs from the transport models are basically graphs of radionuclide concentration in the groundwater plotted against time. After dilution in the receiving surface-water body (e.g., lake, river, bay), these data are the input source terms for the dose models, if dose assessments are required. The dose models calculate radiation dose to individuals and populations. CIRMIS (Comprehensive Information Retrieval and Model Input Sequence) Data System, a storage and retrieval system for model input and output data, including graphical interpretation and display is described. This is the third of four volumes of the description of the CIRMIS Data System.

Friedrichs, D.R.; Argo, R.S.

1980-01-01T23:59:59.000Z

406

Modelica-based Modeling and Simulation to Support Research and Development in Building Energy and Control Systems  

E-Print Network [OSTI]

applied earlier for building energy modeling applicationstowards building HVAC system modeling and simulation. Forof equation-based modeling for building systems. We believe

Wetter, Michael

2010-01-01T23:59:59.000Z

407

Fouling of HVAC fin and tube heat exchangers  

SciTech Connect (OSTI)

Fin and tube heat exchangers are used widely in residential, commercial and industrial HVAC applications. Invariably, indoor and outdoor air contaminants foul these heat exchangers. This fouling can cause decreased capacity and efficiency of the HVAC equipment as well as indoor air quality problems related to microbiological growth. This paper describes laboratory studies to investigate the mechanisms that cause fouling. The laboratory experiments involve subjecting a 4.7 fins/cm (12 fins/inch) fin and tube heat exchanger to an air stream that contains monodisperse particles. Air velocities ranging from 1.5-5.2 m/s (295 ft/min-1024 ft/min) and particle sizes from 1--8.6 {micro}m are used. The measured fraction of particles that deposit as well as information about the location of the deposited material indicate that particles greater than about 1 {micro}m contribute to fouling. These experimental results are used to validate a scaling analysis that describes the relative importance of several deposition mechanisms including impaction, Brownian diffusion, turbophoresis, thermophoresis, diffusiophoresis, and gravitational settling. The analysis is extended to apply to different fin spacings and particle sizes typical of those found in indoor air.

Siegel, Jeffrey; Carey, Van P.

2001-07-01T23:59:59.000Z

408

Sound quality descriptors for HVAC equipment from ARI Standards  

Science Journals Connector (OSTI)

The Air Conditioning and Refrigeration Institute (ARI) has several standards that provide methods to evaluate the sound quality of heating ventilating and air?conditioning (HVAC) equipment. These include Standard 270 Sound rating of outdoor unitary equipment Standard 350 Sound rating of non?ducted indoor air?conditioning equipment and Standard 1140P Procedures for evaluating sound quality of HVAC equipment. The preferred method in these standards is best described in Standard 1140P which uses one?third octave band sound power levels that are weighted to adjust for the sensitivity to frequency distribution and presence of tones and are then converted to a single number sound quality indicator. The tone adjustment is based on the projection of a given one?third octave band level relative to the average of the adjacent one?third octave bands. An alternate use of Zwicker method B to determine loudness and loudness level is also provided in ARI Standard 1140P. These standards provide a convenient method by which complex sounds for similar products may be compared.

2003-01-01T23:59:59.000Z

409

Modeling and optimization of HVAC energy consumption  

Science Journals Connector (OSTI)

A data-driven approach for minimization of the energy to air condition a typical office-type facility is presented. Eight data-mining algorithms are applied to model the nonlinear relationship among energy consumption, control settings (supply air temperature and supply air static pressure), and a set of uncontrollable parameters. The multiple-linear perceptron (MLP) ensemble outperforms other models tested in this research, and therefore it is selected to model a chiller, a pump, a fan, and a reheat device. These four models are integrated into an energy optimization model with two decision variables, the setpoint of the supply air temperature and the static pressure in the air handling unit. The model is solved with a particle swarm optimization algorithm. The optimization results have demonstrated the total energy consumed by the heating, ventilation, and air-conditioning system is reduced by over 7%.

Andrew Kusiak; Mingyang Li; Fan Tang

2010-01-01T23:59:59.000Z

410

TPX: Contractor preliminary design review. Volume 2, PF systems engineering  

SciTech Connect (OSTI)

This system development specification covers the Poloidal Field (PF) Magnet System, WBS 14 in the Princeton Plasma Physics Laboratory TPX Program to build a tokamak fusion reactor. This specification establishes the performance, design, development and test requirements of the PF Magnet System.

Calvin, H.A. [Lawrence Livermore National Lab., CA (United States)

1995-07-28T23:59:59.000Z

411

Joint HVAC transmission EMF environmental study  

SciTech Connect (OSTI)

This document describes the rationale, procedures, and results of a carefully controlled study conducted to establish whether chronic exposure of female (ewe) Suffolk lambs to the environment of a 500-kV 60-Hz transmission line would affect various characteristics of growth, endocrine function, and reproductive development. This experiment used identical housing and management schemes for control and line-exposed ewes, thus minimizing these factors as contributors to between-group experimental error. Further, throughout the 10-month duration of this study, changes in electric and magnetic fields, audible noise, and weather conditions were monitored continuously by a computerized system. Such measurements provided the opportunity to identify any relationship between environmental factors and biological responses. Because of reports in the literature that electric and magnetic fields alter concentrations of melatonin in laboratory animals, the primary objective of this study was to ascertain whether a similar effect occurs in lambs exposed to a 500-kV a-c line in a natural setting. In addition, onset of puberty, changes in body weight, wool growth, and behavior were monitored. To determine whether the environment of a 500-kV line caused stress in the study animals, serum levels of cortisol were measured. The study was conducted at Bonneville Power Administration's Ostrander Substation near Estacada, Oregon.

Stormshak, F.; Thompson, J. (Oregon State Univ., Corvallis, OR (United States))

1992-05-01T23:59:59.000Z

412

Reaerosolization of Fluidized Spores in Ventilation Systems  

Science Journals Connector (OSTI)

...and air conditioning (HVAC) systems. Particles...velocity included the static charge attraction between...determined (12). The static charge from plastic was...deposited on the walls of the HVAC test apparatus (Fig...the duct system. Air pressure was exerted in the chamber...

Paula Krauter; Arthur Biermann

2007-02-09T23:59:59.000Z

413

Low-Volume Power Supply for Vehicular Fuel Injection Systems  

E-Print Network [OSTI]

include reduced fuel consumption, pollution and noise levels. The fuel injectors adjust the engine actuated fuel injection systems have resulted in major advances in internal combustion engines [1]. Those for the engine injection system The fuel is supplied using fast motion injector needles. The motion

Prodiæ, Aleksandar

414

Economic development through biomass system integration. Volumes 2--4  

SciTech Connect (OSTI)

Report documents a feasibility study for an integrated biomass power system, where an energy crop (alfalfa) is the feedstock for a processing plant and a power plant (integrated gasification combined cycle) in a way that benefits the facility owners.

DeLong, M.M.

1995-10-01T23:59:59.000Z

415

Integrated thermal treatment system study: Phase 1 results. Volume 1  

SciTech Connect (OSTI)

An integrated systems engineering approach is used for uniform comparison of widely varying thermal treatment technologies proposed for management of contact-handled mixed low-level waste (MLLW) currently stored in the US Department of Energy complex. Ten different systems encompassing several incineration design options are studied. All subsystems, including facilities, equipment, and methods needed for integration of each of the ten systems are identified. Typical subsystems needed for complete treatment of MLLW are incoming waste receiving and preparation (characterization, sorting, sizing, and separation), thermal treatment, air pollution control, primary and secondary stabilization, metal decontamination, metal melting, mercury recovery, lead recovery, and special waste and aqueous waste treatment. The evaluation is performed by developing a preconceptual design package and planning life-cycle cost (PLCC) estimates for each system. As part of the preconceptual design process, functional and operational requirements, flow sheets and mass balances, and conceptual equipment layouts are developed for each system. The PLCC components estimated are technology development, production facility construction, pre-operation, operation and maintenance, and decontamination and decommissioning. Preconceptual design data and other technology information gathered during the study are examined and areas requiring further development, testing, and evaluation are identified and recommended. Using a qualitative method, each of the ten systems are ranked.

Feizollahi, F.; Quapp, W.J.; Hempill, H.G.; Groffie, F.J.

1994-07-01T23:59:59.000Z

416

Inverted Attic Bulkhead for HVAC Ductwork, Roseville, California (Fact Sheet), Building America Case Study: Efficient Solutions for New and Existing Homes, Building Technologies Office (BTO)  

Broader source: Energy.gov (indexed) [DOE]

Inverted Attic Bulkhead for Inverted Attic Bulkhead for HVAC Ductwork Roseville, California PROJECT INFORMATION Project Name: Long-Term Monitoring of Occupied Test House Location: Roseville, CA Partners: K. Hovnanian® Homes®, www.khov.com IBACOS www.ibacos.com Building Component: Envelope, structural, HVAC ducts Construction: New Application: New; single and/or multifamily Year Tested: 2012 Applicable Climate Zone(s): Hot-dry climate PERFORMANCE DATA HERS Index: 52 Projected Energy Savings: 11 million Btu/year heating and cooling savings Projected Energy Cost Savings: $116/year Modifying the truss system of a new home to accommodate ductwork within an inverted insulated bulkhead along the attic floor can save energy by placing

417

RELAP5/MOD3 code manual: Code structure, system models, and solution methods. Volume 1  

SciTech Connect (OSTI)

The RELAP5 code has been developed for best estimate transient simulation of light water reactor coolant systems during postulated accidents. The code models the coupled behavior of the reactor coolant system and the core for loss-of-coolant accidents, and operational transients, such as anticipated transient without scram, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling, approach is used that permits simulating a variety of thermal hydraulic systems. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater systems. RELAP5/MOD3 code documentation is divided into seven volumes: Volume I provides modeling theory and associated numerical schemes.

NONE

1995-08-01T23:59:59.000Z

418

Dynamic Simulation of a Superinsulated Residential Structure with a Hybrid Desiccant Cooling System.  

E-Print Network [OSTI]

??This thesis explores the efficiency and performance of residential HVAC systems applied to new high performance buildings which meet the standards of the Passivhaus movement.… (more)

O'Kelly, Matthew E.

2012-01-01T23:59:59.000Z

419

Indoor humidity and human health: part II--buildings and their systems  

E-Print Network [OSTI]

Northwest homes. Healthy Buildings: Proceeding of IAQ ’91,inside an HVAC system compatible with a healthy building?Healthy Buildings: Proceeding of IAQ ’91, September,

Arens, Edward A; Baughman, A.

1996-01-01T23:59:59.000Z

420

What are the Best HVAC Solutions for Low-Load, High Performance Homes?"  

Broader source: Energy.gov [DOE]

This presentation was given at the Summer 2012 DOE Building America meeting on July 26, 2012, and addressed the question What are the best HVAC solutions for low-load, high performance homes?"

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Building America Webinar: HVAC Right-Sizing Part 1—Calculating Loads  

Broader source: Energy.gov [DOE]

During this webinar, Building America Research Team IBACOS highlighted the key criteria required to create accurate heating and cooling load calculations. Current industry rules of thumb, perceptions and barriers to right-sizing HVAC were also discussed.

422

DOE Convening Report on Certification of Commercial HVAC and CRE Products  

Broader source: Energy.gov [DOE]

This document is the convening report on the feasibility of a negotiated rulemaking to revise the certification program for commercial HVAC and CRE products published on October 2, 2012.

423

Energy Savings Potential and RD&D Opportunities for Commercial Building HVAC  

Broader source: Energy.gov [DOE]

This Building Technologies Office report assesses heating, ventilation, and air-conditioning (HVAC) technologies for U.S. commercial buildings to identify and provide analysis on 17 priority technology options in various stages of development.

424

Community energy systems and the law of public utilities. Volume 20. Louisiana  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Louisiana governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities--Volume One: An overview. This report also contains a summary of a strategy described in Volume One--An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enchance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

425

Community Energy Systems and the Law of Public Utilities. Volume Twenty-four. Michigan  

SciTech Connect (OSTI)

A detailed description of the laws and programs of the State of Michigan governing the regulation of public energy facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

426

DOE Convening Report on Certification of Commercial HVAC and CRE Products  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Convening Report on Certification of Commercial HVAC and CRE Products, October 2, 2012 Convening Report on Certification of Commercial HVAC and CRE Products, October 2, 2012 1 U.S. DEPARTMENT OF ENERGY CONVENING REPORT ON THE FEASIBILITY OF A NEGOTIATED RULEMAKING TO REVISE THE CERTIFICATION PROGRAM FOR COMMERCIAL HEATING, VENTILATING AIR CONDITIONING AND COMMERCIAL REFRIGERATION EQUIPMENT October 2, 2012 Alan W. Strasser, Esq., MA Convener

427

Economic development through biomass system integration: Volume 1  

SciTech Connect (OSTI)

This report documents a feasibility study for an integrated biomass power system, where an energy crop (alfalfa) is the feedstock for a processing plant and a power plant (integrated gasification combined cycle) in a way that benefits the facility owners. Chapters describe alfalfa basics, production risks, production economics, transportation and storage, processing, products, market analysis, business analysis, environmental impact, and policy issues. 69 figs., 63 tabs.

DeLong, M.M. [Northern States Power Co., Minneapolis, MN (United States)

1995-10-01T23:59:59.000Z

428

GENII: The Hanford Environmental Radiation Dosimetry Software System: Volume 1, Conceptual representation  

SciTech Connect (OSTI)

The Hanford Environmental Dosimetry Upgrade Project was undertaken to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) in updated versions of the environmental pathway analysis models used at Hanford. The resulting second generation of Hanford environmental dosimetry computer codes is compiled in the Hanford Environmental Dosimetry System (Generation II, or GENII). The purpose of this coupled system of computer codes is to analyze environmental contamination resulting from acute or chronic releases to, or initial contamination of, air, water, or soil. This is accomplished by calculating radiation doses to individuals or populations. GENII is described in three volumes of documentation. The first volume describes the theoretical considerations of the system. The second volume is a Users' Manual, providing code structure, users' instructions, required system configurations, and QA-related topics. The third volume is a Code Maintenance Manual for the user who requires knowledge of code detail. It includes code logic diagrams, global dictionary, worksheets, example hand calculations, and listings of the code and its associated data libraries. 72 refs., 15 figs., 34 tabs.

Napier, B.A.; Peloquin, R.A.; Strenge, D.L.; Ramsdell, J.V.

1988-12-01T23:59:59.000Z

429

Frontiers in Public Health Services and Systems Research Volume 1 | Number 1 Article 6  

E-Print Network [OSTI]

improvement plans. Since these activities are fundamental aspects of accreditation and health reformFrontiers in Public Health Services and Systems Research Volume 1 | Number 1 Article 6 4-17-2012 Patterns of Interaction Among Local Public Health Officials and the Adoption of Recommended Practices

Sadeh, Norman M.

430

Evaluation of Emerging Diagnostic Tools for Commercial HVAC Systems  

E-Print Network [OSTI]

six tools in our analysis: Architectural Energy Corporation's ENFORMA? software, Facility Dynamics Engineering's Performance And Continuous Re-commissioning Analysis Tool (PACRAT), Pacific Northwest National Laboratory's Whole Building Diagnostician...

Friedman, H.; Piette, M. A.

2001-01-01T23:59:59.000Z

431

Comparison of Building Energy Modeling Programs: HVAC Systems  

E-Print Network [OSTI]

Comparison of Building Energy Modeling Programs: BuildingComparison of Building Energy Modeling Programs: HVACassumptions of three building energy modeling programs (

Zhou, Xin

2014-01-01T23:59:59.000Z

432

Comparison of Control Strategies for Energy Efficient Building HVAC Systems  

E-Print Network [OSTI]

transfer in rooms in the modelica buildings library. [18] A.Building models are first captured in Modelica [1]to leverage Modelica’s rich building component library and

Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2014-01-01T23:59:59.000Z

433

Co-simulation of innovative integrated HVAC systems in buildings  

E-Print Network [OSTI]

Wetter, M. , 2009. Modelica-based Modeling and Simulation totools like TRNSYS or Modelica [http://www.modelica.org] have

Trcka, Marija

2010-01-01T23:59:59.000Z

434

Model-Based Hierarchical Optimal Control Design for HVAC Systems  

E-Print Network [OSTI]

sun on the external sides of the walls in deriving the differential equations of the temperature distribution

Maasoumy, Mehdi; Pinto, Alessandro; Sangiovanni-Vincentelli, Alberto

2014-01-01T23:59:59.000Z

435

Fault Detection and Diagnosis in Building HVAC Systems  

E-Print Network [OSTI]

box, fan, and heating/cooling coils in air-handling units.fan efficiency and coil duty. In this chapter, we present a statistical approach for rooftop unit

Najafi, Massieh

2010-01-01T23:59:59.000Z

436

Retrofit Analysis of HVAC Systems Using Artificial Neural Networks.  

E-Print Network [OSTI]

??This thesis aims to explore the benefits of retrofits applied to the compressor and burner in the AC and furnace respectively and how best to… (more)

Anand, Anish

2014-01-01T23:59:59.000Z

437

BIM vid installationsprojektering; Planning HVAC systems using BIM.  

E-Print Network [OSTI]

?? Planet rendering plays an important role in universe visualization and geographic visualization. The recent tools and methods allow better data acquisition, usually with very… (more)

Louise, Kollberg

2009-01-01T23:59:59.000Z

438

Development of an adaptive fuzzy logic controller for HVAC system.  

E-Print Network [OSTI]

??An adaptive approach to control a cooling coil chilled water valve operation, called adaptive fuzzy logic control (AFLC), is developed and validated in this study.… (more)

Navale, Rahul Laxman

2006-01-01T23:59:59.000Z

439

Software for fault detection in HVAC systems in commercial buildings  

E-Print Network [OSTI]

The building sector of the United States currently consumes over 41% of the United States primary energy supply. Estimates suggest that between 5 and 30% of any building's annual energy consumption is unknowingly wasted ...

Deshmukh, Suhrid Avinash

2014-01-01T23:59:59.000Z

440

Multi-Sensor Single-Actuator Control of HVAC Systems  

E-Print Network [OSTI]

to replace the single sensor in one room with a network of sensors having at least one sensor per room. This paper addresses this multi-sensor, single-actuator control problem. We used computer simulations and optimization to study the problem. We designed a...

Lin, C.; Auslander, D.; Federspiel, C.

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Co-simulation of innovative integrated HVAC systems in buildings  

E-Print Network [OSTI]

Canada: International Building Perfor- mance SimulationExternal coupling between building energy simulation andexternal coupling of building energy and air ow modeling

Trcka, Marija

2010-01-01T23:59:59.000Z

442

Position feedback system for volume holographic storage media  

DOE Patents [OSTI]

A method of holographic recording in a photorefractive medium wherein stored holograms may be retrieved with maximum signal-to noise ratio (SNR) is disclosed. A plurality of servo blocks containing position feedback information is recorded in the crystal and made non-erasable by heating the crystal. The servo blocks are recorded at specific increments, either angular or frequency, depending whether wavelength or angular multiplexing is applied, and each servo block is defined by one of five patterns. Data pages are then recorded at positions or wavelengths enabling each data page to be subsequently reconstructed with servo patterns which provide position feedback information. The method of recording data pages and servo blocks is consistent with conventional practices. In addition, the recording system also includes components (e.g. voice coil motor) which respond to position feedback information and adjust the angular position of the reference angle of a reference beam to maximize SNR by reducing crosstalk, thereby improving storage capacity.

Hays, Nathan J. (San Francisco, CA); Henson, James A. (Morgan Hill, CA); Carpenter, Christopher M. (Sunnyvale, CA); Akin, Jr.. William R. (Morgan Hill, CA); Ehrlich, Richard M. (Saratoga, CA); Beazley, Lance D. (San Jose, CA)

1998-07-07T23:59:59.000Z

443

Building HVAC Requirements Overview Page 4-1 4 Building HVAC Requirements  

E-Print Network [OSTI]

heating, radiant floor systems, evaporative cooling, gas cooling, ground-source heat pumps, and wood space requirements for additions to existing dwellings and for alterations to existing heating and cooling systems packages. Package C permits electric resistance space heating, but requires significantly greater

444

Demand Response-Enabled Model Predictive HVAC Load Control in Buildings using Real-Time Electricity Pricing.  

E-Print Network [OSTI]

??A practical cost and energy efficient model predictive control (MPC) strategy is proposed for HVAC load control under dynamic real-time electricity pricing. The MPC strategy… (more)

Avci, Mesut

2013-01-01T23:59:59.000Z

445

Systems and methods for controlling energy use in a building management system using energy budgets  

DOE Patents [OSTI]

Systems and methods for limiting power consumption by a heating, ventilation, and air conditioning (HVAC) subsystem of a building are shown and described. A feedback controller is used to generate a manipulated variable based on an energy use setpoint and a measured energy use. The manipulated variable may be used for adjusting the operation of an HVAC device.

Wenzel, Michael J; Drees, Kirk H

2014-09-23T23:59:59.000Z

446

Computerized Control of Environmental Systems  

E-Print Network [OSTI]

This paper examines the actual implementation of two computerized environmental system maintenance control centers. Project "A" is a candy manufacturing plant where controlled systems included subfreezing storage, HVAC, and cold storage (40F to 55F...

Gatti, F. L.

1980-01-01T23:59:59.000Z

447

Mechanically Cooled Large-Volume Germanium Detector Systems for Nuclear Explosion Monitoring  

SciTech Connect (OSTI)

Compact maintenance free mechanical cooling systems are being developed to operate large volume (~570 cm3, ~3 kg, 140% or larger) germanium detectors for field applications. We are using a new generation of Stirling-cycle mechanical coolers for operating the very largest volume germanium detectors with absolutely no maintenance or liquid nitrogen requirements. The user will be able to leave these systems unplugged on the shelf until needed. The flip of a switch will bring a system to life in ~1 hour for measurements. The maintenance-free operating lifetime of these detector systems will exceed five years. These features are necessary for remote long-duration liquid-nitrogen free deployment of large-volume germanium gamma-ray detector systems for Nuclear Explosion Monitoring (NEM). The Radionuclide Aerosol Sampler/Analyzer (RASA) will greatly benefit from the availability of such detectors by eliminating the need for liquid nitrogen at RASA sites while still allowing the very largest available germanium detectors to be utilized. These mechanically cooled germanium detector systems being developed here will provide the largest, most sensitive detectors possible for use with the RASA. To provide such systems, the appropriate technical fundamentals are being researched. Mechanical cooling of germanium detectors has historically been a difficult endeavor. The success or failure of mechanically cooled germanium detectors stems from three main technical issues: temperature, vacuum, and vibration. These factors affect one another. There is a particularly crucial relationship between vacuum and temperature. These factors will be experimentally studied both separately and together to insure a solid understanding of the physical limitations each factor places on a practical mechanically cooled germanium detector system for field use. Using this knowledge, a series of mechanically cooled germanium detector prototype systems are being designed and fabricated. Our collaborators at Pacific Northwest National Laboratory (PNNL) will evaluate these detector systems on the bench top and eventually in RASA systems to insure reliable and practical operation.

Hull, Ethan L.; Pehl, Richard H.; Lathrop, James R.; Martin, Gregory N.; Mashburn, R. B.; Miley, Harry S.; Aalseth, Craig E.; Hossbach, Todd W.; Bowyer, Ted W.

2006-09-21T23:59:59.000Z

448

Utility FGD survey: January--December 1989. Volume 1, Categorical summaries of FGD systems  

SciTech Connect (OSTI)

This is Volume 1 of the Utility flue gas desulfurization (FGD) Survey report, which is generated by a computerized data base management system, represents a survey of operational and planned domestic utility flue gas desulfurization (FGD) systems. It summarizes information contributed by the utility industry, system and equipment suppliers, system designers, research organizations, and regulatory agencies. The data cover system design, fuel characteristics, operating history, and actual system performance. Also included is a unit-by-unit discussion of problems and solutions associated with the boilers, scrubbers, and FGD systems. The development status (operational, under construction, or in the planning stages), system supplier, process, waste disposal practice, and regulatory class are tabulated alphabetically by utility company.

Hance, S.L.; McKibben, R.S.; Jones, F.M.

1992-03-01T23:59:59.000Z

449

Control Volume Analysis, Entropy Balance and the Entropy Production in Flow Systems  

E-Print Network [OSTI]

This chapter concerns "control volume analysis", the standard engineering tool for the analysis of flow systems, and its application to entropy balance calculations. Firstly, the principles of control volume analysis are enunciated and applied to flows of conserved quantities (e.g. mass, momentum, energy) through a control volume, giving integral (Reynolds transport theorem) and differential forms of the conservation equations. Several definitions of steady state are discussed. The concept of "entropy" is then established using Jaynes' maximum entropy method, both in general and in equilibrium thermodynamics. The thermodynamic entropy then gives the "entropy production" concept. Equations for the entropy production are then derived for simple, integral and infinitesimal flow systems. Some technical aspects are examined, including discrete and continuum representations of volume elements, the effect of radiation, and the analysis of systems subdivided into compartments. A Reynolds decomposition of the entropy production equation then reveals an "entropy production closure problem" in fluctuating dissipative systems: even at steady state, the entropy production based on mean flow rates and gradients is not necessarily in balance with the outward entropy fluxes based on mean quantities. Finally, a direct analysis of an infinitesimal element by Jaynes' maximum entropy method yields a theoretical framework with which to predict the steady state of a flow system. This is cast in terms of a "minimum flux potential" principle, which reduces, in different circumstances, to maximum or minimum entropy production (MaxEP or MinEP) principles. It is hoped that this chapter inspires others to attain a deeper understanding and higher technical rigour in the calculation and extremisation of the entropy production in flow systems of all types.

Robert K. Niven; Bernd R. Noack

2014-07-21T23:59:59.000Z

450

Energy Performance and Economic Evaluations of the Geothermal Heat Pump System used in the KnowledgeWorks I and II Buildings, Blacksburg, Virginia.  

E-Print Network [OSTI]

??Heating, Ventilating and Air Conditioning Systems (HVAC) are not only one of the most energy consuming components in buildings but also contribute to green house… (more)

Charoenvisal, Kongkun

2008-01-01T23:59:59.000Z

451

Developing a Standard Method of Test for Packaged, Solid-Desiccant Based Dehumidification Systems  

E-Print Network [OSTI]

for moving process and regeneration air; · May include other system components for filtering, pre of the dehumidification system is presented in terms that would be most familiar and useful to designers of building HVAC that include many of the ancillary components mentioned above. An HVAC system designer who considers a packaged

Oak Ridge National Laboratory

452

Deep Drilling Basic Research: Volume 5 - System Evaluations. Final Report, November 1988--August 1990  

SciTech Connect (OSTI)

This project is aimed at decreasing the costs and increasing the efficiency of drilling gas wells in excess of 15,000 feet. This volume presents a summary of an evaluation of various drilling techniques. Drilling solutions were compared quantitatively against typical penetration rates derived from conventional systems. A qualitative analysis measured the impact of a proposed system on the drilling industry. The evaluations determined that the best candidates f o r improving the speed and efficiency of drilling deep gas wells include: PDC/TSD bits, slim-hole drilling, roller-cone bits, downhole motors, top-driven systems, and coiled-tubing drilling.

None

1990-06-01T23:59:59.000Z

453

Compression effects on pressure loss in flexible HVAC ducts  

SciTech Connect (OSTI)

A study was conducted to evaluate the effect of compression on pressure drop in flexible, spiral wire helix core ducts used in residential and light commercial applications. Ducts of 6 inches, 8 inches and 10 inches (150, 200 and 250 mm) nominal diameters were tested under different compression configurations following ASHRAE Standard 120-1999--Methods of Testing to Determine Flow Resistance of HVAC Air Ducts and Fittings. The results showed that the available published references tend to underestimate the effects of compression. The study demonstrated that moderate compression in flexible ducts, typical of that often seen in field installations, could increase the pressure drop by a factor of four, while further compression could increase the pressure drop by factors close to ten. The results proved that the pressure drop correction factor for compressed ducts cannot be independent of the duct size, as suggested by ASHRAE Fundamentals, and therefore a new relationship was developed for better quantification of the pressure drop in flexible ducts. This study also suggests potential improvements to ASHRAE Standard 120-1999 and provides new data for duct design.

Abushakra, Bass; Walker, Iain S.; Sherman, Max H.

2002-07-01T23:59:59.000Z

454

Hot-gas cleanup system model development. Volume I. Final report  

SciTech Connect (OSTI)

This two-volume report summarizes the state of the art in performance modeling of advanced high-temperature, high-pressure (HTHP) gas cleanup devices. Volume I contains the culmination of the research effort carried over the past 12 months and is a summary of research achievements. Volume II is the user's manual for the computer programs developed under the present research project. In this volume, Section 2 presents background information on pressurized, fluidized-bed combustion concepts, a description of the role of the advanced gas cleanup systems, and a list of advanced gas cleanup systems that are currently in development under DOE sponsorship. Section 3 describes the methodology for the software architecture that forms the basis of the well-disciplined and structured computer programs developed under the present project. Section 4 reviews the fundamental theories that are important in analyzing the cleanup performance of HTHP gas filters. Section 5 discusses the effect of alkali agents in HTHP gas cleanup. Section 6 evaluates the advanced HTHP gas cleanup models based on their mathematical integrity, availability of supporting data, and the likelihood of commercialization. As a result of the evaluation procedure detailed in Section 6, five performance models were chosen to be incorporated into the overall system simulation code, ASPEN. These five models (the electrocyclone, ceramic bag filter, moving granular bed filter, electrostatic granular bed filter, and electrostatic precipitator) are described in Section 7. The method of cost projection for these five models is discussed in Section 8. The supporting data and validation of the computer codes are presented in Section 9, and finally the conclusions and recommendations for the HTHP gas cleanup system model development are given in Section 10. 72 references, 19 figures, 25 tables.

Ushimaru, K.; Bennett, A.; Bekowies, P.J.

1982-11-01T23:59:59.000Z

455

Reducing Building Energy Costs Using Optimized Operation Strategies for Constant Volume Air Handling Systems  

E-Print Network [OSTI]

SDCVP 67.380 $153.200 $41.800 $195.000 $2.89 measured energy consumption for each building. The horizontal axis is the ambient temperature. The venical axis is the average daily energy consumption in MMBtulhr. Figure 5 compares the predicted...REDUCING BUILDING ENERGY COSTS USING OPTIMIZED OPERATION STRATEGIES FOR CONSTANT VOLUME AIR HANDLING SYSTEMS Mingsheng Liu, her Atha, Agarni Reddy Ed White David Claridge and Jeff Haberl Department of Physical Plant Texas A&M University...

Liu, M.; Athar, A.; Reddy, A.; Claridge, D. E.; Haberl, J. S.; White, E.

1994-01-01T23:59:59.000Z

456

Evaluation of HVAC filters as a sampling mechanism for indoor microbial communities  

Science Journals Connector (OSTI)

HVAC filters are in place for extended periods of time and can serve as integrated air samplers. This paper presents a comparison of bacterial and fungal concentrations and communities in HVAC filter dust and other sampling locations in occupied residences and in the unoccupied \\{UTest\\} House. A DNA-based, culture-independent approach was utilized to characterize the microbial communities. Microbial concentrations and communities in HVAC filter dust samples were not statistically different from those in high surface dust samples in occupied homes. Despite the general similarity in the communities, Proteobacteria were present in greater proportion in HVAC filter dust samples than in surface dust samples suggesting the air origin of this phylum. Gram-positive bacteria were present in greater proportion in occupied residences than in an unoccupied test house, confirming the potential association of this group with occupants. HVAC filter microbial communities were not different from those present in a composited month-long indoor air sample providing preliminary evidence that filters could be a viable option for long-term investigation of airborne biological contaminants.

Federico Noris; Jeffrey A. Siegel; Kerry A. Kinney

2011-01-01T23:59:59.000Z

457

Deep Drilling Basic Research: Volume 4 - System Description. Final Report, November 1988--August 1990  

SciTech Connect (OSTI)

The first section of this Volume will discuss the ''Conventional Drilling System''. Today's complex arrangement of numerous interacting systems has slowly evolved from the very simple cable tool rigs used in the late 1800s. Improvements to the conventional drilling rig have varied in size and impact over the years, but the majority of them have been evolutionary modifications. Each individual change or improvement of this type does not have significant impact on drilling efficiency and economics. However, the change is almost certain to succeed, and over time--as the number of evolutionary changes to the system begin to add up--improvements in efficiency and economics can be seen. Some modifications, defined and described in this Volume as Advanced Modifications, have more than just an evolutionary effect on the conventional drilling system. Although the distinction is subtle, there are several examples of incorporated advancements that have had significantly more impact on drilling procedures than would a truly evolutionary improvement. An example of an advanced modification occurred in the late 1970s with the introduction of Polycrystalline Diamond Compact (PDC) drill bits. PDC bits resulted in a fundamental advancement in drilling procedures that could not have been accomplished by an evolutionary improvement in materials metallurgy, for example. The last drilling techniques discussed in this Volume are the ''Novel Drilling Systems''. The extent to which some of these systems have been developed varies from actually being tested in the field, to being no more than a theoretical concept. However, they all have one thing in common--their methods of rock destruction are fundamentally different from conventional drilling techniques. When a novel drilling system is introduced, it is a revolutionary modification of accepted drilling procedures and will completely replace current techniques. The most prominent example of a revolutionary modification in recent history was the complete displacement of cable tool rigs by rotary drilling rigs in the late 1920s.

Anderson, E.E.; Maurer, W.C.; Hood, M.; Cooper, G.; Cook, N.

1990-06-01T23:59:59.000Z

458

Predicting the energy use and operation cost of HVAC air filters  

Science Journals Connector (OSTI)

A model has been developed to predict the energy efficiency and annual operation cost for filters installed in an HVAC air handling system using filter data from standard ASHRAE 52.2-2007 filter tests. Thirty filters from six manufacturers were investigated to determine the most energy efficient and cost effective filtration solutions for an airport installation in Vancouver, Canada. A comparison of the output of the proposed model with the ‘kep’ and Wattage methods was performed to highlight the possible differences in filter choice that would be made using alternative approaches. The outcomes have been shown to differ due to data not incorporated in the older models such as filtration efficiency and particulate concentration. The sensitivity of filter cost to model parameters was also studied. It was found that the concentration of particles in the air stream and the cost of electricity had the largest effect on annual cost of operation. Increasing the concentration of particles in the air stream increases the cost of operating the filter and causes the installation of a prefilter upstream of the primary filter to be more economically attractive. Increasing electricity cost also increases the operation cost but has the reverse effect on attractiveness of prefilter installations.

James F. Montgomery; Sheldon I. Green; Steven N. Rogak; Karen Bartlett

2012-01-01T23:59:59.000Z

459

Impact of Different Glazing Systems on Cooling Load of a Detached Residential Building at Bhubaneswar, India  

E-Print Network [OSTI]

assuming north?south and east?west facings of the building. For each orientation, different types of glazing (Table 4) and different glazing areas are considered. The first case(the base case) assumes a single clear glazing with a window-to-wall ratio.... Floor plan of the east-west oriented residential building taken for study (not to scale) Table 1. The zones basic characteristics Zone Area (m2) Volume (m3) Occupancy (people/m2) Venti- lation (l/s) HVAC system Bed room1 15.12 52...

Sahoo, P. K.; Sahoo, R.

2010-01-01T23:59:59.000Z

460

Logue and Singer, HVAC&R, 20(2): 264-275, 2014. Energy Impacts of Effective Residential Range Hood Use, LBNL-6683E Page 1  

E-Print Network [OSTI]

Logue and Singer, HVAC&R, 20(2): 264-275, 2014. Energy Impacts of Effective Residential Range Hood and Singer, HVAC&R, 20(2): 264-275, 2014. Energy Impacts of Effective Residential Range Hood Use, LBNL-6683E Laboratory is an equal opportunity employer. #12;Logue and Singer, HVAC&R, 20(2): 264-275, 2014. Energy

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

462

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

463

Community Energy Systems and the Law of Public Utilities. Volume Forty-seven. Vermont  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of Vermont governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

464

Community Energy Systems and the Law of Public Utilities. Volume Eleven. Florida  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Florida governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D A; Weaver, C L

1981-01-01T23:59:59.000Z

465

Community Energy Systems and the Law of Public Utilities. Volume Fourteen. Idaho  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Idaho governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

466

Community Energy Systems and the Law of Public Utilities. Volume Three. Alabama  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Alabama governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

467

Community Energy Systems and the Law of Public Utilities. Volume Twenty-one. Maine  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Maine governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

468

Community Energy Systems and the Law of Public Utilities. Volume Forty-nine. Washington  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of Washington governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

469

Community Energy Systems and the Law of Public Utilities. Volume Twenty-two. Maryland  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Maryland governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

470

Community Energy Systems and the Law of Public Utilities. Volume Six. Arkansas  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Arkansas governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

471

Community Energy Systems and the Law of Public Utilities. Volume Twelve. Georgia  

SciTech Connect (OSTI)

A detailed description of the laws and programs of the State of Georgia governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

472

Community Energy Systems and the Law of Public Utilities. Volume Forty-eight. Virginia  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of Virginia governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

473

Community Energy Systems and the Law of Public Utilities. Volume Fifty-one. Wisconsin  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of Wisconsin governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

474

Community Energy Systems and the Law of Public Utilities. Volume Nine. Connecticut  

SciTech Connect (OSTI)

A detailed description of the laws and programs of the State of Connecticut governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

475

Community Energy Systems and the Law of Public Utilities. Volume Seventeen. Iowa  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Iowa governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

476

Community Energy Systems and the Law of Public Utilities. Volume Forty. Pennsylvania  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of Pennsylvania governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

477

Community Energy Systems and the Law of Public Utilities. Volume Nineteen. Kentucky  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Kentucky governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

478

Community Energy Systems and the Law of Public Utilities. Volume Thirteen. Hawaii  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Hawaii governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

479

Community Energy Systems and the Law of Public Utilities. Volume Forty-five. Texas  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of Texas governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

480

Community Energy Systems and the Law of Public Utilities. Volume Thirty-nine. Oregon  

SciTech Connect (OSTI)

A detailed description is presented of the laws and programs of the State of Oregon governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hvac systems volume" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Community Energy Systems and the Law of Public Utilities. Volume Twenty-five. Minnesota  

SciTech Connect (OSTI)

A detailed description is given of the laws and programs of the State of Minnesota governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

Feurer, D.A.; Weaver, C.L.

1981-01-01T23:59:59.000Z

482

Radon Mitigation in Schools Utilising Heating, Ventilating and Air Conditioning Systems  

Science Journals Connector (OSTI)

......and Air Conditioning Engineers (ASHRAE) standard Ventilation for Acceptable Indoor Air Quality...Two case studies are presented where HVAC technology was implemented for controlling...system in a two-storey building. The HVAC system's controls were restored and modified......

G. Fisher; B. Ligman; T. Brennan; R. Shaughnessy; B.H. Turk; B. Snead

1994-12-01T23:59:59.000Z

483

Energy Management and Information Systems  

E-Print Network [OSTI]

?infrastructure energy?audits,?HVAC?upgrades,? heat?recovery,?etc. Improve?operations processes?and?day?to?day? operations,?retro? commissioning ENERGY?MANAGEMENT?INFORMATION?SYSTEM the?project Hardware ? $3.0?million?investment ? 400+?meters...

Conraud, J.

2013-01-01T23:59:59.000Z

484

A system for calculating the merchantable volume of oak trees in the northwest of the state of Chihuahua, Mexico  

Science Journals Connector (OSTI)

The taper functions of Kozak (1988), Bi (2000) and Fang et al. (2000) were comparatively analyzed in the present paper to develop a system for calculating the merchantable volume of oaks in the northwestern regio...

Marín Pompa-García; José Javier Corral-Rivas…

2009-12-01T23:59:59.000Z

485

Comparisons of type and volume of growth media and two cropping systems for production of greenhouse tomatoes Lycopersicon esculentum Mill  

E-Print Network [OSTI]

COMPARISONS OF TYPE AND VOLUME OF GROWTH MEDIA AND TWO CROPPING SYSTEMS FOR PRODUCTION OF GREENHOUSE TOMATOES LYCOPERSICON ESCULENTUM MILL. A Thesis by JOHN DARRYL BYRD Submitted to the Graduate College of Texas A & M University in partial... fulfillment of the requirement for the degree of MASTER OF SCIENCE August 1977 Major Subject: Horticulture COMPARISONS OF TYPE AND VOLUME OF GROWTH MEDIA AND TWO CROPPING SYSTEMS FOR PRODUCTIOF OF GREENHOUSE TOMATOES LYCOPERSICON ESCULENTUM MILL. A...

Byrd, John Darryl

2012-06-07T23:59:59.000Z

486

Selecting Thermal Storage Systems for Schools  

E-Print Network [OSTI]

-in freezers and refrigerators. 10. Occupancy sensors for lighting and HVAC control. 11. Electrical distribution system broken down into HVAC, lighting, and miscellaneous loads with each load submetered. 12. All the meters and submeters can be remotely... start automatically when area served is occupied. I. DDC Control System - Controls equipment, provides system operation information, generates historical data files for meter readings and selected system points. The greatest innovation...

Maxwell, C. L.

1990-01-01T23:59:59.000Z

487

AUTOMATIC VARIABLE VENTILATION CONTROL SYSTEMS BASED ON AIR QUALITY DETECTION  

E-Print Network [OSTI]

Control Systems Based on Air Quality Detection Isaac Turiel,HVAC CONTROL SYSTEM BASED ON AIR QUALITY SENSING To Zl)(lecontrol systems based on air quality detection Isaac Turiel,

Turiel, Isaac

2011-01-01T23:59:59.000Z

488

A Study of Pressure Losses in Residential Air Distribution Systems Bass Abushakra Iain S. Walker Max H. Sherman  

E-Print Network [OSTI]

. The experimental tests conformed to ASHRAE Standard 120P ­ Methods of Testing to Determine Flow Resistance of HVAC on the power consumption and the overall performance of the HVAC system. To satisfy the ARI 210 in the air-distribution system is critical. Proctor and Parker (2000) noted that the measured external static

489

Model Code for the Control of Residential HVAC Distribution System Leakage and HVAC-Induced Building Leakage  

E-Print Network [OSTI]

, Underwriters Laboratories, Inc., the Air Conditioning Contractors Of America, the Thermal Insulation Manufacturers Association, the National Fire Protection Association, and the Gypsum Association....

Wemhoff, P.

1990-01-01T23:59:59.000Z

490

2014-04-28 Issuance: Certification of Commercial HVAC, Water Heating, and Refrigeration Equipment; Final Rule  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register final rule regarding the certification of commercial heating, ventilation, and air-conditioning (HVAC), water heating (WH), and refrigeration (CRE) equipment, as issued by the Deputy Assistant Secretary for Energy Efficiency on April 28, 2014.

491

Estimates of HVAC filtration efficiency for fine and ultrafine particles of outdoor origin  

Science Journals Connector (OSTI)

Abstract This work uses 194 outdoor particle size distributions (PSDs) from the literature to estimate single-pass heating, ventilating, and air-conditioning (HVAC) filter removal efficiencies for PM2.5 and ultrafine particles (UFPs: HVAC filters identified in the literature. Filters included those with a minimum efficiency reporting value (MERV) of 5, 6, 7, 8, 10, 12, 14, and 16, as well as HEPA filters. We demonstrate that although the MERV metric defined in ASHRAE Standard 52.2 does not explicitly account for UFP or PM2.5 removal efficiency, estimates of filtration efficiency for both size fractions increased with increasing MERV. Our results also indicate that outdoor PSD characteristics and assumptions for particle density and typical size-resolved infiltration factors (in the absence of HVAC filtration) do not drastically impact estimates of HVAC filter removal efficiencies for PM2.5. The impact of these factors is greater for UFPs; however, they are also somewhat predictable. Despite these findings, our results also suggest that MERV alone cannot always be used to predict UFP or PM2.5 removal efficiency given the various size-resolved removal efficiencies of different makes and models, particularly for MERV 7 and MERV 12 filters. This information improves knowledge of how the MERV designation relates to PM2.5 and UFP removal efficiency for indoor particles of outdoor origin. Results can be used to simplify indoor air quality modeling efforts and inform standards and guidelines.

Parham Azimi; Dan Zhao; Brent Stephens

2014-01-01T23:59:59.000Z

492

Building America Expert Meeting: Transitioning Traditional HVAC Contractors to Whole House Performance Contractors  

Broader source: Energy.gov [DOE]

This report outlines findings resulting from a U.S. Department of Energy Building America expert meeting held on March 29, 2011 by IBACOS to determine how HVAC companies can transition from a traditional contractor status to a service provider for whole house energy upgrade contracting.

493

HYBRID GROUND SOURCE HEAT PUMP SYSTEM SIMULATION USING VISUAL MODELING TOOL FOR HVACSIM+  

E-Print Network [OSTI]

, and plotting the output are also included. INTRODUCTION HVACSIM+, which stands for `HVAC SIMulation PLUS other systems', is a non-proprietary simulation package developed at the National Institute of Standards and Technology (NIST), Gaithersburg, Maryland, U.S.A. It is capable of modeling HVAC (heating, ventilation

494

Operation Diagnostics - Use of Operation Patterns to Verify and Optimize Building and System Operation  

E-Print Network [OSTI]

.ensan.de), and the Annex 40 "Commissioning of Buildings and HVAC Systems for Improved Energy Per- formance" (www.commissioning-hvac.org) within the ECBCS Program of the International Energy Agency (IEA). The author is grateful for the free use of Pia, countless emails...

Baumann, O.

2004-01-01T23:59:59.000Z

495

Volume Comparison  

Gasoline and Diesel Fuel Update (EIA)

Volume Comparison Volume Comparison Data for October 2013 | Release Date: January 7, 2014 | Complete XLS File Beginning with data for August 2010, natural gas consumption for the residential and commercial sectors was derived from the total system sendout reported by local distribution companies on Form EIA-857, "Monthly Report of Natural Gas Purchases and Deliveries." The new methodology was designed to yield estimates that more closely reflect calendar month consumption patterns. Total system sendout is the sum of all volumes dispatched into the service territory during the report month, less any storage injections and deliveries to points outside the service territory. Previously, residential and commercial consumption estimates were based solely on reported sector

496

1996 international conference on power electronics, drives and energy systems for industrial growth: Proceedings. Volume 1  

SciTech Connect (OSTI)

This book contains Volume 1 of the proceedings of the IEEE International Conference on Power Electronics, Drives and Energy Systems for Industrial Growth held January, 1996, in New Delhi. The topics of the papers include resonant and soft switching converters, induction motor drives, solar power generation, control aspects of power generation, PWM and DC/DC converters, field oriented control of AC machines, wind power generation, analysis of electrical machines, topology and control of power electronic converters, switched reluctance and permanent magnet motor drives, active filters and VAR compensation schemes, analysis and design of induction generators/motors, simulation of power electronics converters and drive, brushless and special electrical machines, UPS and battery energy storage systems.

Murthy, S.S.; Roy, S. [eds.] [Indian Inst. of Tech., New Delhi (India); Divan, D. [ed.] [Univ. of Wisconsin, Madison, WI (United States); Doradla, S.R. [ed.] [Indian Inst. of Tech., Kanpur (India); Murthy, B.V. [ed.] [General Motors, Detroit, MI (United States)

1995-12-31T23:59:59.000Z

497

The relationship between filter pressure drop, indoor air quality, and energy consumption in rooftop HVAC units  

Science Journals Connector (OSTI)

Abstract HVAC filters are commonly used to decrease exposure to particulate matter, yet little is known about the energy impacts and air quality consequences of high efficiency filters installed in commercial buildings. To explore these effects, system airflow, filter and coil pressure drop, fan pressure rise, and power draw were measured, and cooling capacity and compressor power were modeled for at least four filter pressure drops in 15 rooftop units equipped with and without fan speed control. Energy implications and clean-air-delivery-rate were estimated for a large dataset of filters divided into four efficiency (MERV) categories. Field measurements conducted on units without fan speed control showed that increased filter pressure drop decreased flow, cooling capacity, and power. For a unit with fan speed control, the same increase in pressure drop resulted in the same magnitude change of fan power but in the opposite direction, and other parameters were unchanged. Replacing MERV 8 with MERV 13/14 resulted in higher energy consumption (2–4%) during cooling mode for both unit types, energy savings during fan-only mode (8–13%) in units without fan speed control, and increased energy consumption in fan-only mode (11–18%) in the unit with fan speed control. Energy consumption increases were offset by improvement in clean-air-delivery-rate, especially for PM2.5 (2.9–3.8 times increase going from MERV 8 to MERV 13/14), with larger benefits achieved for the unit with fan speed control. A comprehensive understanding of the impact of filtration is essential to selecting the appropriate efficiency of filters that ensures low-energy use and a healthy indoor environment.

Marwa Zaatari; Atila Novoselac; Jeffrey Siegel

2014-01-01T23:59:59.000Z

498

Buildings Energy Data Book: 5.5 Thermal Distribution Systems  

Buildings Energy Data Book [EERE]

5 5 Typical Commercial Building Thermal Energy Distribution Design Load Intensities (Watts per SF) Distribution System Fans Other Central System Supply Fans Cooling Tower Fan Central System Return Fans Air-Cooled Chiller Condenser Fan 0.6 Terminal Box Fans 0.5 Exhaust Fans (2) Fan-Coil Unit Fans (1) Condenser Fans 0.6 Packaged or Split System Indoor Blower 0.6 Pumps Chilled Water Pump Condenser Water Pump Heating Water Pump Note(s): Source(s): 0.1 - 0.2 0.1 - 0.2 1) Unducted units are lower than those with some ductwork. 2) Strong dependence on building type. BTS/A.D. Little, Energy Consumption Characteristics of Commercial Building HVAC Systems, Volume II:Thermal Distribution, Auxiliary Equipment, and Ventilation, Oct. 1999, Table 3-1, p. 3-6. 0.3 - 1.0 0.1 - 0.3 0.1 - 0.4

499

Introducing Energy Management Systems into Smaller Facilities  

E-Print Network [OSTI]

Many small and medium sized commercial buildings are energy hogs. Typically they were designed and built to meet low first cost criteria. Control system capability is usually minimal, insulation is thin, glass areas are large, and HVAC equipment...

Lawrence, J. A.

1983-01-01T23:59:59.000Z

500

ACCEPTANCE REQUIREMENTS AND HOME ENERGY RATING SYSTEMS  

E-Print Network [OSTI]

TESTING REGULATIONS CALIFORNIA ENERGY COMMISSION for the 2005 BUILDING ENERGY EFFICIENCY STANDARDS FOR NONRESIDENTIAL HGH- RISE RESIDENTIAL and HOTELS/MOTELS BUILDINGS STANDARDS/REGULATIONS July 2005 Effective ............................................................ NJ-3 NJ.4 Packaged HVAC Systems