  1. Optimized Fan Control In Variable Air Volume HVAC Systems Using Static Pressure Resets: Strategy Selection and Savings Analysis 

    E-Print Network [OSTI]

    Kimla, John

    2010-07-14

    The potential of static pressure reset (SPR) control to save fan energy in variable air volume HVAC systems has been well documented. Current research has focused on the creation of reset strategies depending on specific ...

  2. VOLUME 11, NUMBER 2 HVAC&R RESEARCH APRIL 2005 Ground-Source Heat Pump System Research--

    E-Print Network [OSTI]

    VOLUME 11, NUMBER 2 HVAC&R RESEARCH APRIL 2005 165 EDITORIAL Ground-Source Heat Pump System Research-- Past, Present, and Future J.D. Spitler, PhD, PE Fellow ASHRAE Ground-source heat pump (GSHP to Heinrich Zoelly is the first known reference to ground-source heat pump systems.2 In the US, some ground-source

  3. Renovating Residential HVAC Systems HVAC Systems

    E-Print Network [OSTI]

    Efficiency and Renewable Energy, Building Technologies, of the US Department of Energy (DOE) under contract Guideline for Residential HVAC Retrofits (http://www.eere.energy.gov/buildings/building, two of the houses were evaluated by an independent energy efficiency contractor. One of the test

  4. Air-Side Energy Use Calculations for Four HVAC Systems: Dual Duct Constant Volume (DDCAV), Dual Duct Variable Volume (DDVAV), Constant Volume with Reheat (CAVRH), Variable Volume with Reheat (VAVRH), Four Pipe Fan Coil Unit (FC), Four Pipe Induction Unit (FI), and Single Zone (SZ) Systems, Revised June 2002 

    E-Print Network [OSTI]

    Haberl, J. S.; Bou-Saada, T. E.; Saman, N. F.

    2001-01-01

    This report contains engineering calculations for seven (7) air-side, heating, ventilating and air conditioning systems (HVAC) systems, including: dual duct constant volume (DDCAV), dual duct variable volume (DDVAV), ...

  5. Wireless Demand Response Controls for HVAC Systems

    E-Print Network [OSTI]

    Federspiel, Clifford

    2010-01-01

    conditioning. Figure 2: Wireless discharge air temperatureWireless Demand Response Controls for HVAC Systems Cliffordcontrol software and wireless hardware that could enable

  6. Energy Efficient HVAC System for Distributed Cooling/Heating...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Efficient HVAC System for Distributed CoolingHeating with Thermoelectric Devices Energy Efficient HVAC System for Distributed CoolingHeating with Thermoelectric Devices 2012 DOE...

  7. Integration of HVAC System Design with Simplified Duct Distribution...

    Energy Savers [EERE]

    Integration of HVAC System Design with Simplified Duct Distribution - Building America Top Innovation Integration of HVAC System Design with Simplified Duct Distribution - Building...

  8. Development of a High-Efficiency Zonal Thermoelectric HVAC System...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    a High-Efficiency Zonal Thermoelectric HVAC System for Automotive Applications Development of a High-Efficiency Zonal Thermoelectric HVAC System for Automotive Applications...

  9. Improving efficiency of a vehicle HVAC system with comfort modeling...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    efficiency of a vehicle HVAC system with comfort modeling, zonal design, and thermoelectric devices Improving efficiency of a vehicle HVAC system with comfort modeling, zonal...

  10. Study of lubricant circulation in HVAC systems. Volume 1: Description of technical effort and results; Final technical report, March 1995--April 1996

    SciTech Connect (OSTI)

    Biancardi, F.R.; Michels, H.H.; Sienel, T.H.; Pandy, D.R.

    1996-10-01

    The purpose of this program was to conduct experimental and analytical efforts to determine lubricant circulation characteristics of new HFC/POE pairs and HFC/mineral oil pairs in a representative central residential HVAC system and to compare their behavior with the traditional HCFC-22/mineral oil (refrigerant/lubricant) pair. A dynamic test facility was designed and built to conduct the experimental efforts. This facility provided a unique capability to visually and physically measure oil circulation rates, on-line, in operating systems. A unique on-line ultraviolet-based measurement device was used to obtain detailed data on the rate and level of lubricant oil circulated within the operating heat pump system. The experimental and analytical data developed during the program are presented as a function of vapor velocity, refrigerant/lubricant viscosity, system features and equipment. Both visual observations and instrumentation were used to understand ``worst case`` oil circulation situations. This report is presented in two volumes. Volume 1 contains a complete description of the program scope, objective, test results summary, conclusions, description of test facility and recommendations for future effort. Volume 2 contains all of the program test data essentially as taken from the laboratory dynamic test facility during the sequence of runs.

  11. Theoretical Minimum Energy Use of a Building HVAC System 

    E-Print Network [OSTI]

    Tanskyi, O.

    2011-01-01

    This paper investigates the theoretical minimum energy use required by the HVAC system in a particular code compliant office building. This limit might be viewed as the "Carnot Efficiency" for HVAC system. It assumes that all ventilation and air...

  12. Implementation and main results Ecient Management of HVAC Systems

    E-Print Network [OSTI]

    Schenato, Luca

    Motivation Implementation and main results Ecient Management of HVAC Systems Mirco Rampazzo Management of HVAC Systems #12;Motivation Implementation and main results Outline 1 Motivation HVAC Systems Multiple-chiller systems 2 Implementation and main results Models, Control and Optimization Examples Mirco

  13. Text-Alternative Version of Building America Webinar: High Performance HVAC Systems, Part II: Low-Load HVAC Systems for Single and Multifamily Applications

    Broader source: Energy.gov [DOE]

    Transcript for the Nov. 16 webinar, High Performance HVAC Systems, Part II: Low-Load HVAC Systems for Single and Multifamily Applications.

  14. Pitfalls in Building and HVAC Systems 

    E-Print Network [OSTI]

    Gidwani, B. N.

    1985-01-01

    AND HVAC SYSTEMS B. N. Gidwani, P.E. Roy F. Weston, Inc. West Chester, Pennsylvania ABSTRACT The purpose of an energy audit is to identify and analyze areas of energy consumption and to pro pose methods of conservation. In the process... opportunities for energy savings. When performing a detailed energy audit, the fol lowing areas should be examined with respect to the building envelope: Walls ? Roofs ? Windows ? Doors ? Ceiling Height ? In order to minimize energy losses through...

  15. Low-Global Warming Potential HVAC System with Ultra-Small Centrifugal...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Global Warming Potential HVAC System with Ultra-Small Centrifugal Compression Low-Global Warming Potential HVAC System with Ultra-Small Centrifugal Compression Mechanical...

  16. Improving the Efficiency of Light-Duty Vehicle HVAC Systems using...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Light-Duty Vehicle HVAC Systems using Zonal Thermoelectric Devices and Comfort Modeling Improving the Efficiency of Light-Duty Vehicle HVAC Systems using Zonal Thermoelectric...

  17. HVAC & Building Management Control System Energy Efficiency Replacements

    SciTech Connect (OSTI)

    Hernandez, Adriana

    2012-09-21

    The project objective was the replacement of an aging, un-repairable HVAC system which has grown inefficient and a huge energy consumer with low energy and efficient HVAC units, and installation of energy efficient building control technologies at City's YMCA Community Center.

  18. Heat recovery and the economizer for HVAC systems

    SciTech Connect (OSTI)

    Anantapantula, V.S. . Alco Controls Div.); Sauer, H.J. Jr. )

    1994-11-01

    This articles examines why a combined heat reclaim/economizer system with priority to heat reclaim operation is most likely to result in the least annual total HVAC energy. PC-based, hour-by-hour simulation programs evaluate annual HVAC energy requirements when using combined operation of heat reclaim and economizer cycle, while giving priority to operation of either one. These simulation programs also enable the design engineer to select the most viable heat reclaim and/or economizer system for any given type of HVAC system serving the building internal load level, building geographical location and other building/system variables.

  19. The Optimization of Control Parameters for VAV HVAC System Commissioning 

    E-Print Network [OSTI]

    Song, S.; Maehara, K.; Sagara, N.

    2006-01-01

    kind of commissioning technique as follows. We identified the dynamic characteristics of components of an actual VAV HVAC system such as rooms, VAV dampers, two way valves and chilled water coils, and verified the behaviors of the models and choose...

  20. Case Study of an Innovative HVAC System with Integral Dehumidifier 

    E-Print Network [OSTI]

    Shirey, D. B.; Raustad, R. A.

    2008-01-01

    . Although this technology is not new, the integration of a dehumidification system with a standard air conditioner is an innovative strategy that can be used to address moisture control in buildings. This new HVAC configuration would provide a low...

  1. Evaluation of Emerging Diagnostic Tools for Commercial HVAC Systems 

    E-Print Network [OSTI]

    Friedman, H.; Piette, M. A.

    2001-01-01

    This paper compares and evaluates the capabilities of six emerging diagnostic tools for commercial HVAC systems. We present a brief description of the diagnostic tools, and then focus on evaluating the features of the tools. We include the following...

  2. Review of Residential Low-Load HVAC Systems

    SciTech Connect (OSTI)

    Brown, Scott A.; Thornton, Brian; Widder, Sarah H.

    2013-09-01

    In support of the U.S. Department of Energy’s (DOE’s) Building America Program, Pacific Northwest National Laboratory (PNNL) conducted an investigation to inventory commercially available HVAC technologies that are being installed in low-load homes. The first step in this investigation was to conduct a review of published literature to identify low-load HVAC technologies available in the United States and abroad, and document the findings of existing case studies that have evaluated the performance of the identified technologies. This report presents the findings of the literature review, identifies gaps in the literature or technical understanding that must be addressed before low-load HVAC technologies can be fully evaluated, and introduces PNNL’s planned research and analysis for this project to address identified gaps and potential future work on residential low-load HVAC systems.

  3. Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage

    E-Print Network [OSTI]

    Mammoli, Andrea

    2014-01-01

    Assisted HVAC System with Thermal Storage A. Mammoli a , M.HVAC system with thermal storage. Energy and Buildings, 42(ASSISTED HVAC SYSTEM WITH THERMAL STORAGE A. Mammoli a , M.

  4. An Application of State-Of-The-Art HVAC and Building Systems 

    E-Print Network [OSTI]

    Fiorino, D. P.

    1988-01-01

    This case study describes the successful application of state-of-the-art HVAC and building systems at a large commercial office and industrial facility. The facility's exterior envelope systems, HVAC systems, lighting ...

  5. Energy-Efficient Building HVAC Control Using Hybrid System LBMPC

    E-Print Network [OSTI]

    Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

    2012-01-01

    Improving the energy-efficiency of heating, ventilation, and air-conditioning (HVAC) systems has the potential to realize large economic and societal benefits. This paper concerns the system identification of a hybrid system model of a building-wide HVAC system and its subsequent control using a hybrid system formulation of learning-based model predictive control (LBMPC). Here, the learning refers to model updates to the hybrid system model that incorporate the heating effects due to occupancy, solar effects, outside air temperature (OAT), and equipment, in addition to integrator dynamics inherently present in low-level control. Though we make significant modeling simplifications, our corresponding controller that uses this model is able to experimentally achieve a large reduction in energy usage without any degradations in occupant comfort. It is in this way that we justify the modeling simplifications that we have made. We conclude by presenting results from experiments on our building HVAC testbed, which s...

  6. Variable-Speed, Low-Cost Motor for Residential HVAC Systems ...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    HVAC Systems Variable-Speed, Low-Cost Motor for Residential HVAC Systems Lower-Cost, Variable-Speed Electric Motor Improves Energy Efficiency In 2011, the U.S. industrial,...

  7. Measuring Advances in HVAC Distribution System Design

    SciTech Connect (OSTI)

    Franconi, E.

    1998-05-01

    Substantial commercial building energy savings have been achieved by improving the performance of the HV AC distribution system. The energy savings result from distribution system design improvements, advanced control capabilities, and use of variable-speed motors. Yet, much of the commercial building stock remains equipped with inefficient systems. Contributing to this is the absence of a definition for distribution system efficiency as well as the analysis methods for quantifying performance. This research investigates the application of performance indices to assess design advancements in commercial building thermal distribution systems. The index definitions are based on a first and second law of thermodynamics analysis of the system. The second law or availability analysis enables the determination of the true efficiency of the system. Availability analysis is a convenient way to make system efficiency comparisons since performance is evaluated relative to an ideal process. A TRNSYS simulation model is developed to analyze the performance of two distribution system types, a constant air volume system and a variable air volume system, that serve one floor of a large office building. Performance indices are calculated using the simulation results to compare the performance of the two systems types in several locations. Changes in index values are compared to changes in plant energy, costs, and carbon emissions to explore the ability of the indices to estimate these quantities.

  8. Performance Validation and Energy Analysis of HVAC Systems using Simulation

    E-Print Network [OSTI]

    1 Performance Validation and Energy Analysis of HVAC Systems using Simulation Tim Salsbury and Rick This paper describes the concept of using simulation as a tool for performance validation and energy analysis and supervision of building systems in order to optimize operational performance. The paper describes one way

  9. RF propagation in an HVAC duct system: impulse response characteristics of the channel

    E-Print Network [OSTI]

    Stancil, Daniel D.

    RF propagation in an HVAC duct system: impulse response characteristics of the channel Pavel V, the heating, ventilation, and air conditioning (HVAC) duct system in buildings is a complex network of hollow at RF and microwave frequencies of com- mon interest. HVAC ducts can be used as a wireless communication

  10. System-Level Monitoring and Diagnosis of Building HVAC System

    E-Print Network [OSTI]

    Wu, Siyu

    2013-01-01

    and global relationships between end-use energy consumptionHVAC Energy Consumption Due to rapid global population

  11. A systems approach to retrofitting residential HVAC systems

    SciTech Connect (OSTI)

    McWilliams, J.A.; Walker, I.S.

    2004-05-01

    A Best Practices Guide for retrofitting residential HVAC systems has recently been completed by DOE. The guide uses diagnostics and checklists to guide the user to specific retrofit packages that maximize retrofit energy savings, comfort and safety potential. The guide uses a systems approach to retrofitting where the interaction of different building components is considered throughout the retrofit selection process. For example, added building envelope insulation reduces building loads so that smaller capacity HVAC systems can be used. In this study, several houses were surveyed using the Best Practices Guide and a single house was selected for retrofitting. The objectives were to demonstrate how a successful system-wide retrofit can be carried out and to provide feedback to improve the guide. Because it represents a departure from current practice, a key aspect of this study was to investigate the interactions with contractors and code officials who are unfamiliar with the systems approach. The study found that the major barrier to the systems approach in retrofits was in changing the working practices of contractors and code officials.

  12. Model Predictive Control of HVAC Systems: Implementation and Testing at the University of California, Merced

    E-Print Network [OSTI]

    Haves, Phillip

    2010-01-01

    plants  with  thermal  storage.   The  project objectives systems with  active thermal storage systems in commercial of  HVAC  systems  with  thermal  storage.   Modulation  of 

  13. Energy Renovations: Volume 14: HVAC - A Guide for Contractors to Share with Homeowners

    SciTech Connect (OSTI)

    Gilbride, Theresa L.; Baechler, Michael C.; Hefty, Marye G.; Hand, James R.; Love, Pat M.

    2011-08-29

    This report was prepared by PNNL for DOE's Building America program and is intended as a guide that energy performance contractors can share with homeowners to describe various energy-efficient options for heating, cooling, and ventilating existing homes. The report provides descriptions of many common and not-so-common HVAC systems, including their advantages and disadvantages, efficiency ranges and characteristics of high-performance models, typical costs, and climate considerations. The report also provides decision trees and tables of useful information for homeowners who are making decisions about adding, replacing, or upgrading existing HVAC equipment in their homes. Information regarding home energy performance assessments (audits) and combustion safety issues when replacing HVAC equipment are also provided.

  14. An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings

    E-Print Network [OSTI]

    Trcka, Marija

    2010-01-01

    Heating and Cooling Task 12B and IEA Energy Conservation inNeymark, J. and Judkoff, R. 2002. IEA HVAC BESTEST volume 1,Technical report of a IEA Solar Heating and Cooling

  15. Multi-objective optimization of the HVAC (heating, ventilation, and air conditioning) system performance

    E-Print Network [OSTI]

    Kusiak, Andrew

    Multi-objective optimization of the HVAC (heating, ventilation, and air conditioning) system, ventilation, and air conditioning) system in a typical office facility is presented. A multi-layer perceptron. 1. Introduction HVAC (heating, ventilating and air conditioning) systems are designed to maintain

  16. Design of Control Systems for HVAC Applications 

    E-Print Network [OSTI]

    Smith, A. L.

    1984-01-01

    The design and application of temperature control systems on a commercial building will bring the question to mind: Should the system be Pneumatic? Should it be Electronic? There is concern as to which system will be more appropriate to a certain...

  17. Reliability and Functional Availability of HVAC Systems 

    E-Print Network [OSTI]

    Myrefelt, S.

    2004-01-01

    the probability that a component or a system works when no maintenance is made. A system with a high reliability thus has minimal maintenance requirements; it is a robust system. The decision capability is used to assess the organisation?s capacity to start... the system is in operation in relation to intended operating time. It mainly shows the technical capability to keep on operating while maintenance is being carried out. Systems that must be taken out of operation for longer repair works have a lower level...

  18. Thermal Storage Options for HVAC Systems 

    E-Print Network [OSTI]

    Weston, R. F.; Gidwani, B. N.

    1986-01-01

    is based on the specific heat of water rather than the latent 'heat of fusion of ice as in ice storage, it requires about 4 times the storage capacity of an equivalent ice storage system. ? Salt Storage: This system utilizes eutectic salts which... freeze and melt around 47 o F. Exist ing chillers can be easily retrofitted for salt storage or chilled water storage. For ice stor age systems, a direct refrigerant system or glycol chillers are suitable. This paper discusses the details of each...

  19. Index to Evaluate Energy Efficiency of the Building HVAC System 

    E-Print Network [OSTI]

    Wang, L.; Wang, L.; Claridge,D.

    2014-01-01

    Efficiency of the Entire Building HVAC System Presented by Dr. Claridge Date: 09/15/2014 ESL-IC-14-09-15 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 2Outline •Why we need the Energy.../Load Ratio •How to get the Energy/Load Ratio •Methodology Adjustment •Case Study •Results Showed by tables and Plots ESL-IC-14-09-15 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 3...

  20. Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage

    E-Print Network [OSTI]

    Mammoli, Andrea

    2014-01-01

    of a solar-thermal- assisted hvac system. Energy andsolar thermal collectors using flat reflective surfaces. Solar Energy,of a solar-assisted HVAC system with thermal storage. Energy

  1. Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture

    E-Print Network [OSTI]

    Stancil, Daniel D.

    Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture Ariton E. Xhafa, Paisarn ducts for wireless communications. The proposed solution is based on a new system architecture design of the indoor wireless networks that use the heating, ventilation, and air conditioning (HVAC) ducts

  2. Electric, Gas, and Electric/Gas Energy Options for Cold-Air HVAC Systems 

    E-Print Network [OSTI]

    Meckler, G.

    1989-01-01

    An important aspect of the design of cost-effective HVAC systems today is (a) sensitivity to the cost impact of the interplay of utility demand charges, time-of-day rates, gas rates, and gas/electric utility incentive programs vis-ŕ-vis HVAC system...

  3. Wireless Demand Response Controls for HVAC Systems

    SciTech Connect (OSTI)

    Federspiel, Clifford

    2009-06-30

    The objectives of this scoping study were to develop and test control software and wireless hardware that could enable closed-loop, zone-temperature-based demand response in buildings that have either pneumatic controls or legacy digital controls that cannot be used as part of a demand response automation system. We designed a SOAP client that is compatible with the Demand Response Automation Server (DRAS) being used by the IOUs in California for their CPP program, design the DR control software, investigated the use of cellular routers for connecting to the DRAS, and tested the wireless DR system with an emulator running a calibrated model of a working building. The results show that the wireless DR system can shed approximately 1.5 Watts per design CFM on the design day in a hot, inland climate in California while keeping temperatures within the limits of ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy.

  4. Case study field evaluation of a systems approach to retrofitting a residential HVAC system

    SciTech Connect (OSTI)

    Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

    2003-09-01

    This case study focusing on a residence in northern California was undertaken as a demonstration of the potential of a systems approach to HVAC retrofits. The systems approach means that other retrofits that can affect the HVAC system are also considered. For example, added building envelope insulation reduces building loads so that smaller capacity HVAC system can be used. Secondly, we wanted to examine the practical issues and interactions with contractors and code officials required to accomplish the systems approach because it represents a departure from current practice. We identified problems in the processes of communication and installation of the retrofit that led to compromises in the final energy efficiency of the HVAC system. These issues must be overcome in order for HVAC retrofits to deliver the increased performance that they promise. The experience gained in this case study was used to optimize best practices guidelines for contractors (Walker 2003) that include building diagnostics and checklists as tools to assist in ensuring the energy efficiency of ''house as a system'' HVAC retrofits. The best practices guidelines proved to be an excellent tool for evaluating the eight existing homes in this study, and we received positive feedback from many potential users who reviewed and used them. In addition, we were able to substantially improve the energy efficiency of the retrofitted case study house by adding envelope insulation, a more efficient furnace and air conditioner, an economizer and by reducing duct leakage.

  5. Microsoft Word - HVAC_20100824.doc

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    design for the High-Level Waste (HLW) Vitrification Facility's heating, ventilation and air-conditioning (HVAC) system. Critical to facility operations, the HVAC system will...

  6. Energy Conservation Studies of Existing HVAC Systems 

    E-Print Network [OSTI]

    Patterson, C. L.; Phelan, T. R.

    1985-01-01

    that projected savings can be real ized. The following examples are from an electronics manufacturing facility. Over 140 air handlers serving offices, laboratori es and clean roan manu facturing areas were investigated. The design cooling load of the central... preventive maintenance program with regular tube cleaning intervals, automated brush clean system for condensers, and proper condenser water chemical treatment would provide effective means of controlling the deterioration of fouling factors. ? Increase...

  7. Case Studies of Commissioning HVAC Systems 

    E-Print Network [OSTI]

    Browning, B. K.

    2001-01-01

    and changed in character, but not eliminated. As shown by Figure 3, the space relative humidity was still very high, but now the problem was primarily during unoccupied periods. 70.0 72.5 75.0 77.5 60 70 80 60 80 17 Sun 18 Mon 19 Tue 20 Wed 21 Thu 22 Fri 23... & condenser. He felt it was wise to check before starting the system. 70 75 80 60 70 80 60 70 80 29 Sat May 99 30 Sun 31 Mon 1 Jun 2 Wed 3 Thu 4 Fri Deg FDeg F% RH se7.pl1 Space Temp 1-2 Supply Temp Space RH Figure 6 - Space Temp, Supply Temp, & Relative...

  8. Dynamic Modeling and Wavelet-Based Multi-Parametric Tuning and Validation for HVAC Systems 

    E-Print Network [OSTI]

    Liang, Shuangshuang

    2014-07-10

    Dynamic Heating, Ventilation, and Air-Conditioning (HVAC) system models are used for the purpose of control design, fault detection and diagnosis, system analysis, design and optimization. Therefore, ensuring the accuracy ...

  9. Direct Digital Control- A Tool for Energy Management of HVAC Systems 

    E-Print Network [OSTI]

    Swanson, K.

    1993-01-01

    Direct digital control (DDC) applied to heating, ventilating, and air-conditioning (HVAC) systems corrects many of the deficiencies of conventional automatic temperature control systems. By applying new control sequences, ...

  10. HVAC Market Study:

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    HVAC Market Study: Understanding how energy efficient products get to market Fall 2014 through Winter 2015 Research Manager: Carrie Cobb, clcobb@bpa.gov, 503-230-4985 HVAC systems...

  11. A Unified and Integrated Energy Management System for HVAC Spaces and Power House 

    E-Print Network [OSTI]

    Kaya, A.; Debban, G. D.

    1988-01-01

    AND INTEGRATED ENERGY MANAGEMENT SYSTEM FOR HVAC SPACES AND POWER HOUSE A.Kaya The University of Akron Mechanical Engineering Akron,OH 44325 ABSTRACT This paper describes a totally integrated energy management system throughout the plant and facilities.... The equipment involves: the power flant (boilers, cogeneration turbines, chillers); HVAC 0 buildings; air handling and other distribution systems. The energy management system has the architecture for data transmission and processing including multilevel...

  12. Analysis of the HVAC System at the Willow Branch Intermediate School 

    E-Print Network [OSTI]

    Wei, G.

    1997-01-01

    This report presents an analysis of the HVAC system at the Willow Branch Intermediate School for the MEEN 685 class project. The school is located at College Station, Texas. A portion of the school belonged to Oakwood Intermediate School which...

  13. Development of HVAC System Performance Criteria Using Factorial Design and DOE-2 Simulation 

    E-Print Network [OSTI]

    Hou, D.; Jones, J. W.; Hunn, B. D.; Banks, J. A.

    1996-01-01

    A new approach is described for the development of Heating, Ventilating, and Air-conditioning (HVAC) System Performance Criteria for the Texas Building Energy Design Standard. This approach integrates a design of experimental methodology and DOE-2...

  14. Energy Savings with Energy-Efficient HVAC Systems in Commercial Buildings of Hong Kong 

    E-Print Network [OSTI]

    Yang, J.; Chan, K.; Wu, X.

    2006-01-01

    Kong for sustainable development. In this study, the major factors influencing the electricity use of HVAC systems are studied with the building energy simulation program EnergyPlus, which include chiller efficiency, space cooling temperature, variable...

  15. Computational Study on Thermal Properties of HVAC System with Building Structure Thermal Storage 

    E-Print Network [OSTI]

    Sato, Y.; Sagara, N.; Ryu, Y.; Maehara, K.; Nagai, T.

    2007-01-01

    Building structure thermal storage (BSTS) HVAC systems can store heat during nighttime thermal storage operation (nighttime operation hours) by using off-peak electricity and release it in the daytime air-conditioning operation (daytime operation...

  16. CO2 - Based Demand-Controlled Ventilation Control Strategies for Multi-Zone HVAC Systems 

    E-Print Network [OSTI]

    Nassif, N.

    2011-01-01

    CO2-based demand-controlled ventilation DCV strategy offers a great opportunity to reduce energy consumption in HVAC systems while providing the required ventilation. However, implementing CO2-based DCV under ASHRAE 62.1.2004 through 2010...

  17. Energy Master Plans for Sustainable, High Performance HVAC and Associated Systems for Hot and Humid Climates 

    E-Print Network [OSTI]

    Maisey, G. E.; Milestone, B.

    2004-01-01

    for SUSTAINABLE, HIGH PERFORMANCE HVAC & ASSOCIATED SYSTEMS for HOT AND HUMID CLIMATES Grahame E. Maisey, P.E. Beverly Milestone Chief Engineer President GEMCO Energy Master Planners GEMCO Energy Master Planners Div. of Building... the pieces of true sustainable design and then assemble the pieces into whole sustainable, high performance HVAC systems. These are presented to the owner as the target to reach. A detailed, in depth energy master plan is the ideal way to achieve...

  18. Improving the Efficiency of Light-Duty Vehicle HVAC Systems using Zonal Thermoelectric Devices and Comfort Modeling

    Broader source: Energy.gov [DOE]

    Summarizes results from a study to identify and demonstrate technical and commercial approaches necessary to accelerate the deployment of zonal TE HVAC systems in light-duty vehicles

  19. ETME 422 -REFRIGERATION & HVAC SYSTEMS FALL 2011 LEC -10:00 -10:50am M W F RH 312

    E-Print Network [OSTI]

    Dyer, Bill

    , fans, compressors, heat exchangers, heaters, refrigerators, etc.) of heating, ventilation, air Load - Introduction HVAC Systems Comfort and Health Solar Radiation Radiant Time Series Method Moist

  20. Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage

    E-Print Network [OSTI]

    Mammoli, Andrea

    2014-01-01

    1980, but its thermal solar and storage systems received achiller. A 30 m heat storage tank solar decouples heatfacility with thermal storage and solar- assisted HVAC for

  1. Deposition of Biological Aerosols on HVAC Heat Exchangers

    E-Print Network [OSTI]

    on biological contamination on HVAC coils. Muyshondt et al. (1998) discuss the HVAC system as both a source

  2. EVALUATION OF EMERGING DIAGNOSTIC TOOLS FOR COMMERCIAL HVAC SYSTEMS Hannah Friedman Mary Ann Piette

    E-Print Network [OSTI]

    management control systems (EMCS), utility demand metering, and dedicated monitoring systems. By combining and Electric's Universal Translator, UC Berkeley's Fan System Tools, and Silicon Energy's Enterprise Energy, ventilating, and air-conditioning (HVAC) systems (Gregerson, 1997, Claridge et al., 2000). If these energy

  3. Minimization of energy consumption in HVAC systems with data-driven models and an interior-point method

    E-Print Network [OSTI]

    Kusiak, Andrew

    -driven approach is applied to minimize energy consumption of a heating, ventilating, and air conditioning (HVAC, ventilating and air conditioning (HVAC) systems have been recognized as major consumers of energy air conditioning system. Parameshwaran et al. [9] developed a genetic fuzzy optimization method

  4. Integrated high efficiency blower apparatus for HVAC systems

    DOE Patents [OSTI]

    Liu, Xiaoyue; Weigman, Herman; Wang, Shixiao

    2007-07-24

    An integrated centrifugal blower wheel for a heating, ventilation and air conditioning (HVAC) blower unit includes a first blade support, a second blade support, and a plurality of S-shaped blades disposed between the first and second blade supports, wherein each of the S-shaped blades has a trailing edge bent in a forward direction with respect to a defined direction of rotation of the wheel.

  5. Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond

    E-Print Network [OSTI]

    Diamond, Richard

    carrying out a proof of operation. In large modern buildings, the energy management and control system monitoring period following each change in setpoint, characterize system performance. These indicesAutomated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond Lawrence Berkeley

  6. FAULT DETECTION IN HVAC SYSTEMS USING MODEL-BASED FEEDFORWARD CONTROL

    E-Print Network [OSTI]

    Diamond, Richard

    the controller with a simulated dual-duct air-handling unit. We also discuss recent experiences of implementing, Comfort/Energy, Control/Simulation/Field Tests, Air-Conditioning Systems, Feedforward Control, Diagnostics 1 INTRODUCTION Heating, ventilating, and air-conditioning (HVAC) systems are typically controlled

  7. System-Level Monitoring and Diagnosis of Building HVAC System

    E-Print Network [OSTI]

    Wu, Siyu

    2013-01-01

    integrated into building automation systems, particularlydata from existing building automation systems (BASs) forcapabilities of modern building automation and control

  8. A BEMS-Assisted Commissioning Tool to Improve the Energy Performance of HVAC Systems 

    E-Print Network [OSTI]

    Choiniere, D.; Corsi, M.

    2003-01-01

    -ASSISTED COMMISSIONING TOOL TO IMPROVE THE ENERGY PERFORMANCE OF HVAC SYSTEMS Daniel Choiničre Technology Expert CANMET-Energy Technology Centre Natural Resources Canada 1615 Lionel-Boulet Blvd., P.O. Box 4800, Varennes, Quebec, J3X 1S6, Canada Maria Corsi1...

  9. System-Level Monitoring and Diagnosis of Building HVAC System

    E-Print Network [OSTI]

    Wu, Siyu

    2013-01-01

    systems coupling on building energy performance, Energy andabout the building energy performance without consideringuser behavior on building energy performance [141]. With an

  10. Optimization of Ice Thermal Storage Systems Design for HVAC Systems 

    E-Print Network [OSTI]

    Nassif, N.; Hall, C.; Freelnad, D.

    2013-01-01

    energy cost. A tool for optimal ice storage design is developed, considering the charging and discharge times and optimal sizing of ice thermal storage system. Detailed simulation studies using real office building located near Orlando, FL including...

  11. Detection and diagnosis of faults and energy monitoring of HVAC systems with least-intrusive power analysis

    E-Print Network [OSTI]

    Luo, Dong, 1966-

    2001-01-01

    Faults indicate degradation or sudden failure of equipment in a system. Widely existing in heating, ventilating, and air conditioning (HVAC) systems, faults always lead to inefficient energy consumption, undesirable indoor ...

  12. Building America Best Practices Series Volume 14 - HVAC. A Guide for Contractors to Share with Homeowners

    SciTech Connect (OSTI)

    Baechler, Michael C.; Gilbride, Theresa L.; Hefty, Marye G.; Hand, James R.; Love, Pat M.

    2011-08-01

    This guide, which is part of a series of Best Practices guides produced by DOE’s Building America program, describes ways homeowners can reduce their energy costs and improve the comfort, health, and safety of their homes by upgrading their heating, ventilation, and air conditioning (HVAC) equipment.

  13. COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM

    SciTech Connect (OSTI)

    Jiang Zhu; Yong X. Tao

    2011-11-01

    In this paper, a hotel with hybrid geothermal heat pump system (HyGSHP) in the Pensacola is selected and simulated by the transient simulation software package TRNSYS [1]. To verify the simulation results, the validations are conducted by using the monthly average entering water temperature, monthly facility consumption data, and etc. And three types of HVAC systems are compared based on the same building model and HVAC system capacity. The results are presented to show the advantages and disadvantages of HyGSHP compared with the other two systems in terms of energy consumptions, life cycle cost analysis.

  14. Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage

    E-Print Network [OSTI]

    Mammoli, Andrea

    2014-01-01

    performance of a solar-thermal- assisted hvac system. Energyfor rows of fixed solar thermal collectors using flatassisted by a 232 m solar thermal array providing heat to a

  15. Predictive modeling and optimization of a multi-zone HVAC system with data mining and firefly algorithms

    E-Print Network [OSTI]

    Kusiak, Andrew

    . Sakulpipatsin et al. [6] proposed an extended method for energy and exergy analysis of HVAC systems data-driven framework is examined in the computational studies. A sensitivity analysis of the potential

  16. ZonePAC: Zonal Power Estimation and Control via HVAC Metering and Occupant Feedback

    E-Print Network [OSTI]

    Gupta, Rajesh

    Ventillation and Air Conditioning (HVAC) systems ac- count for nearly 40% of primary energy consumption Measurement, Human Factors, Design Keywords HVAC, Thermostat, Energy Estimation, Variable Air Volume, User buildings [2], and is one of the prime targets for improving building energy efficiency. Several studies

  17. Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes - Business Case Assessment

    SciTech Connect (OSTI)

    Baxter, Van D

    2007-05-01

    The long range strategic goal of the Department of Energy's Building Technologies (DOE/BT) Program is to create, by 2020, technologies and design approaches that enable the construction of net-zero energy homes at low incremental cost (DOE/BT 2005). A net zero energy home (NZEH) is a residential building with greatly reduced needs for energy through efficiency gains, with the balance of energy needs supplied by renewable technologies. While initially focused on new construction, these technologies and design approaches are intended to have application to buildings constructed before 2020 as well resulting in substantial reduction in energy use for all building types and ages. DOE/BT's Emerging Technologies (ET) team is working to support this strategic goal by identifying and developing advanced heating, ventilating, air-conditioning, and water heating (HVAC/WH) technology options applicable to NZEHs. Although the energy efficiency of heating, ventilating, and air-conditioning (HVAC) equipment has increased substantially in recent years, new approaches are needed to continue this trend. Dramatic efficiency improvements are necessary to enable progress toward the NZEH goals, and will require a radical rethinking of opportunities to improve system performance. The large reductions in HVAC energy consumption necessary to support the NZEH goals require a systems-oriented analysis approach that characterizes each element of energy consumption, identifies alternatives, and determines the most cost-effective combination of options. In particular, HVAC equipment must be developed that addresses the range of special needs of NZEH applications in the areas of reduced HVAC and water heating energy use, humidity control, ventilation, uniform comfort, and ease of zoning. In FY05 ORNL conducted an initial Stage 1 (Applied Research) scoping assessment of HVAC/WH systems options for future NZEHs to help DOE/BT identify and prioritize alternative approaches for further development. Eleven system concepts with central air distribution ducting and nine multi-zone systems were selected and their annual and peak demand performance estimated for five locations: Atlanta (mixed-humid), Houston (hot-humid), Phoenix (hot-dry), San Francisco (marine), and Chicago (cold). Performance was estimated by simulating the systems using the TRNSYS simulation engine (Solar Energy Laboratory et al. 2006) in two 1800-ft{sup 2} houses--a Building America (BA) benchmark house and a prototype NZEH taken from BEopt results at the take-off (or crossover) point (i.e., a house incorporating those design features such that further progress towards ZEH is through the addition of photovoltaic power sources, as determined by current BEopt analyses conducted by NREL). Results were summarized in a project report, 'HVAC Equipment Design options for Near-Zero-Energy Homes--A Stage 2 Scoping Assessment', ORNL/TM-2005/194 (Baxter 2005). The 2005 study report describes the HVAC options considered, the ranking criteria used, and the system rankings by priority. Table 1 summarizes the energy savings potential of the highest scoring options from the 2005 study for all five locations. All system options were scored by the ORNL building equipment research team and by William Goetzler of Navigant Consulting. These scores were reviewed by DOE/BT's Residential Integration program leaders and Building America team members. Based on these results, the two centrally ducted integrated heat pump (IHP) systems (air source and ground source versions) were selected for advancement to Stage 2 (Exploratory Development) business case assessments in FY06. This report describes results of these business case assessments. It is a compilation of three separate reports describing the initial business case study (Baxter 2006a), an update to evaluate the impact of an economizer cooling option (Baxter 2006b), and a second update to evaluate the impact of a winter humidification option (Baxter 2007). In addition it reports some corrections made subsequent to release of the first two reports to correct so

  18. Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel

    E-Print Network [OSTI]

    2012-01-01

    Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel

  19. Proposal for the award of a contract for the design, supply, installation and commissioning of an HVAC (Heating, Ventilation and Air Conditioning) system for Building 3862

    E-Print Network [OSTI]

    2014-01-01

    Proposal for the award of a contract for the design, supply, installation and commissioning of an HVAC (Heating, Ventilation and Air Conditioning) system for Building 3862

  20. Energy Savings Potential of Flexible and Adaptive HVAC Distribution Systems for Office Buildings

    SciTech Connect (OSTI)

    Loftness, Vivian; Brahme, Rohini; Mondazzi, Michelle; Vineyard, Edward; MacDonald, Michael

    2002-06-01

    It has been understood by architects and engineers that office buildings with easily re-configurable space and flexible mechanical and electrical systems are able to provide comfort that increases worker productivity while using less energy. Raised floors are an example of how fresh air, thermal conditioning, lighting needs, and network access can be delivered in a flexible manner that is not ''embedded'' within the structure. What are not yet documented is how well these systems perform and how much energy they can save. This area is being investigated in phased projects of the 21st Century Research Program of the Air-conditioning and Refrigeration Technology Institute. For the initial project, research teams at the Center for Building Performance and Diagnostics, Pittsburgh, Pennsylvania, and Oak Ridge National Laboratory, Oak Ridge, Tennessee, documented the diversity, performance, and incidence of flexible and adaptive HVAC systems. Information was gathered worldwide from journal and conference articles, case studies, manufactured products and assemblies, and interviews with design professionals. Their report thoroughly describes the variety of system types along with the various design alternatives observed for plenums, diffusers, individual control, and system integration. Many of the systems are illustrated in the report and the authors provide quantitative and qualitative comparisons. Among conclusions regarding key design issues, and barriers to widespread adoption, the authors state that flexible and adaptive HVAC systems, such as underfloor air, perform as well if not better than ceiling-based systems. Leading engineers have become active proponents after their first experience, which is resulting in these flexible and adaptive HVAC systems approaching 10 percent of the new construction market. To encourage adoption of this technology that improves thermal comfort and indoor air quality, follow-on work is required to further document performance. Architects, professional engineers, and commercial real estate developers will benefit from the availability of information that quantifies energy savings, first cost construction differences, and additional operating costs created when office space must be reconfigured to accommodate new tenants.

  1. Continuous Energy Management of the HVAC&R System in an Office Building System Operation and Energy Consumption for the Eight Years after Building Completion 

    E-Print Network [OSTI]

    Akashi, Y.; Shinozaki, M.; Kusuda, R.; Ito, S.

    2006-01-01

    The authors continuously studied the energy consumption of a heating, ventilating, air- conditioning and refrigerating (HVAC&R) system in an office for the operation of the system in terms of its expected performance. A fault in the system control...

  2. Combined solar and internal load effects on selection of heat reclaim-economizer HVAC systems

    SciTech Connect (OSTI)

    Sauer, H.J. Jr.; Howell, R.H.; Wang, Z. . Dept. of Mechanical Engineering)

    1990-05-01

    The concern for energy conservation has led to the development and use of heat recovery systems which reclaim the building internal heat before it is discarded in the exhaust air. On the other hand, economizer cycles have been widely used for many years in a variety of types of HVAC systems. Economizer cycles are widely accepted as a means to reduce operating time for chilling equipment when cool outside air is available. It has been suggested that heat reclaim systems should not be used in conjunction with an HVAC system which incorporates an economizer cycle because the economizer operation would result in heat being exhausted which might have been recovered. Others suggest that the economizer cycle can be used economically in a heat recovery system if properly controlled to maintain an overall building heat balance. This study looks at potential energy savings of such combined systems with particular emphasis on the effects of the solar load (amount of glass) and the internal load level (lights, people, appliances, etc.). For systems without thermal storage, annual energy savings of up to 60 percent are predicted with the use of heat reclaim systems in conjunction with economizers when the heat reclaim has priority. These results demonstrate the necessity of complete engineering evaluations if proper selection and operation of combined heat recovery and economizer cycles are to be obtained. This paper includes the basic methodology for making such evaluations.

  3. Modeling and Control of AHUs in Building HVAC Systems

    E-Print Network [OSTI]

    Liang, Wei

    2014-01-01

    integration. R and is easily implemented into • The algorithm is based on WebCTRL , building automation systems.

  4. Plutonium Finishing Plant (PFP) HVAC System Component Index

    SciTech Connect (OSTI)

    DICK, J.D.

    2000-02-28

    The Plutonium Finishing Plant (PFP) WAC System includes sub-systems 25A through 25K. Specific system boundaries and justifications are contained in HNF-SD-CP-SDD-005, ''Definition and Means of Maintaining the Ventilation System Confinement Portion of the PFP Safety Envelope.'' The procurement requirements associated with the system necessitates procurement of some system equipment as Commercial Grade Items in accordance with HNF-PRO-268, ''Control of Purchased Items and Services.'' This document lists safety class and safety significant components for the Heating Ventilation Air Conditioning and specifies the critical characteristics for Commercial Grade Items, as required by HNF-PRO-268 and HNF-PRO-1819. These are the minimum specifications that the equipment must meet in order to properly perform its safety function. There may be several manufacturers or models that meet the critical characteristics for any one item.

  5. Building HVAC Control System Interaction Issues: Two Case Studies 

    E-Print Network [OSTI]

    Chen, Q.; Deng, S.; Toole, C.; Xu, C.

    2007-01-01

    the existing systems. This paper presents the CC measures identified in two case studies to improve building comfort and energy efficiency with minimal hardware investment....

  6. Low-Load HVAC Systems for Single and Multifamily Applications

    Energy Savers [EERE]

    during system on cycle Room-to-Thermostat Temperature Drift during unoccupied period Entry slightly warmer, balancing risk during winter Humidifier? May perform better in...

  7. Decentralized model predictive control of a multiple evaporator HVAC system 

    E-Print Network [OSTI]

    Elliott, Matthew Stuart

    2009-05-15

    Vapor compression cooling systems are the primary method used for refrigeration and air conditioning, and as such are a major component of household and commercial building energy consumption. Application of advanced control ...

  8. COMPREHENSIVE DIAGNOSTIC AND IMPROVEMENT TOOLS FOR HVAC-SYSTEM INSTALLATIONS IN LIGHT COMMERCIAL BUILDINGS

    SciTech Connect (OSTI)

    Abram Conant; Mark Modera; Joe Pira; John Proctor; Mike Gebbie

    2004-10-31

    Proctor Engineering Group, Ltd. (PEG) and Carrier-Aeroseal LLP performed an investigation of opportunities for improving air conditioning and heating system performance in existing light commercial buildings. Comprehensive diagnostic and improvement tools were created to address equipment performance parameters (including airflow, refrigerant charge, and economizer operation), duct-system performance (including duct leakage, zonal flows and thermal-energy delivery), and combustion appliance safety within these buildings. This investigation, sponsored by the National Energy Technology Laboratory, a division of the U.S. Department of Energy, involved collaboration between PEG and Aeroseal in order to refine three technologies previously developed for the residential market: (1) an aerosol-based duct sealing technology that allows the ducts to be sealed remotely (i.e., without removing the ceiling tiles), (2) a computer-driven diagnostic and improvement-tracking tool for residential duct installations, and (3) an integrated diagnosis verification and customer satisfaction system utilizing a combined computer/human expert system for HVAC performance. Prior to this work the aerosol-sealing technology was virtually untested in the light commercial sector--mostly because the savings potential and practicality of this or any other type of duct sealing had not been documented. Based upon the field experiences of PEG and Aeroseal, the overall product was tailored to suit the skill sets of typical HVAC-contractor personnel.

  9. The Effect of Optimal Tuning of the Heating/Cooling Curve in AHU of HVAC System in Real Practice 

    E-Print Network [OSTI]

    2004-01-01

    TNO Bouw, The Netherlands Page: 1 of 12 THE EFFECT OF OPTIMAL TUNING OF THE HEATING-/ COOLING CURVE IN AHU OF HVAC SYSTEM IN REAL PRACTISE P.A. (Bert) Elkhuizen(1), J.E. (Jan Ewout) Scholten(1), H.C. (Henk) Peitsman(1), A (Ad) Kooijman (2... of the heating/ cooling curve in the central Air Handling Unit?s (AHU?s) of HVAC systems without loss of comfort. In most cases the number of complaints will also be reduced. The method can be used in both new and existing buildings. The approach will generate...

  10. Development of a High-Efficiency Zonal Thermoelectric HVAC System for Automotive Applications

    Broader source: Energy.gov [DOE]

    Identify a technical and business approach to accelerate the deployment of light-duty automotive TE HVAC technology, maintain occupant comfort, and improve energy efficiency.

  11. Value impact analysis of Generic Issue 143, Availability of Heating, Ventilation, Air Conditioning (HVAC) and Chilled Water Systems

    SciTech Connect (OSTI)

    Daling, P.M.; Marler, J.E.; Vo, T.V.; Phan, H.; Friley, J.R. [Pacific Northwest Lab., Richland, WA (United States)

    1993-11-01

    This study evaluates the values (benefits) and impacts (costs) associated with potential resolutions to Generic Issue 143, ``Availability of HVAC and Chilled Water Systems.`` The study identifies vulnerabilities related to failures of HVAC, chilled water, and room cooling systems; develops estimates of room heatup rates and safety-related equipment vulnerabilities following losses of HVAC/room cooler systems; develops estimates of the core damage frequencies and public risks associated with failures of these systems; develops three proposed resolution strategies to this generic issue; and performs a value/impact analysis of the proposed resolutions. Existing probabilistic risk assessments for four representative plants, including one plant from each vendor, form the basis for the core damage frequency and public risk calculations. Both internal and external events were considered. It was concluded that all three proposed resolution strategies exceed the $1,000/person-rem cost-effectiveness ratio. Additional evaluations were performed to develop ``generic`` insights on potential design-related and configuration-related vulnerabilities and potential high-frequency ({approximately}1E-04/RY) accident sequences that involve failures of HVAC/room cooling functions. It was concluded that, although high-frequency accident sequences may exist at some plants, these high-frequency sequences are plant-specific in nature or have been resolved through hardware and/or operational changes. The plant-specific Individual Plant Examinations are an effective vehicle for identification and resolution of these plant-specific anomalies and hardware configurations.

  12. Chapter 5: Lighting, HVAC, and Plumbing

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    : Lighting, HVAC, and Plumbing High-Performance Engineering Design Lighting System Design Mechanical System Design Central Plant Systems Plumbing and Water Use Building Control...

  13. Variable Refrigerant Flow HVAC 

    E-Print Network [OSTI]

    Jones, S.

    2013-01-01

    Variable refrigerant flow technology HVAC CATEE 2013 San Antonio, TX ESL-KT-13-12-33 CATEE 2013: Clean Air Through Energy Efficiency Conference, San Antonio, Texas Dec. 16-18 What is the acronym VRF? ? Variable Refrigerant Flow Operates like a... heat pump utilizing VFD Inverter Compressors and LEV’s Unlike conventional commercial and residential HVAC systems in the USA The predominate method of cooling and heating in the world ESL-KT-13-12-33 CATEE 2013: Clean Air Through Energy Efficiency...

  14. Energy Savings From System Efficiency Improvements in Iowa’s HVAC SAVE Program

    SciTech Connect (OSTI)

    Yee, S.; Baker, J.; Brand, L.; Wells, J.

    2013-08-01

    The objective of this project is to explore the energy savings potential of maximizing furnace and distribution system performance by adjusting operating, installation, and distribution conditions. The goal of the Iowa HVAC System Adjusted and Verified Efficiency (SAVE) program is to train contractors to measure installed system efficiency as a diagnostic tool to ensure that the homeowner achieves the energy reduction target for the home rather than simply performing a tune-up on the furnace or having a replacement furnace added to a leaky system. The PARR research team first examined baseline energy usage from a sample of 48 existing homes, before any repairs or adjustments were made, to calculate an average energy savings potential and to determine which system deficiencies were prevalent. The results of the baseline study of these homes found that, on average, about 10% of the space heating energy available from the furnace was not reaching the conditioned space. In the second part of the project, the team examined a sample of 10 homes that had completed the initial evaluation for more in-depth study. For these homes, the diagnostic data shows that it is possible to deliver up to 23% more energy from the furnace to the conditioned space by doing system tune ups with or without upgrading the furnace. Replacing the furnace provides additional energy reduction. The results support the author's belief that residential heating and cooling equipment should be tested and improved as a system rather than a collection of individual components.

  15. Analysis of Innovative HVAC System Technologies and Their Application for Office Buildings in Hot and Humid Climates 

    E-Print Network [OSTI]

    Tanskyi, Oleksandr

    2012-02-14

    parameters for the Wisenbaker Engineering Research Center HVAC system simulation model.................................................................. 66 Table 3.8. DOE-2.1E system hourly reports variables... used in commercial buildings design are not adequate to save energy in both depth (savings per square foot) and scale (square footage improved each year) (RMI 2010). There are several ways to decrease energy consumption and CO2 emission caused...

  16. Initial Business Case Analysis of Two Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes

    SciTech Connect (OSTI)

    Baxter, Van D

    2006-11-01

    The long range strategic goal of the Department of Energy's Building Technologies (DOE/BT) Program is to create, by 2020, technologies and design approaches that enable the construction of net-zero energy homes at low incremental cost (DOE/BT 2005). A net zero energy home (NZEH) is a residential building with greatly reduced needs for energy through efficiency gains, with the balance of energy needs supplied by renewable technologies. While initially focused on new construction, these technologies and design approaches are intended to have application to buildings constructed before 2020 as well resulting in substantial reduction in energy use for all building types and ages. DOE/BT's Emerging Technologies (ET) team is working to support this strategic goal by identifying and developing advanced heating, ventilating, air-conditioning, and water heating (HVAC/WH) technology options applicable to NZEHs. Although the energy efficiency of heating, ventilating, and air-conditioning (HVAC) equipment has increased substantially in recent years, new approaches are needed to continue this trend. Dramatic efficiency improvements are necessary to enable progress toward the NZEH goals, and will require a radical rethinking of opportunities to improve system performance. The large reductions in HVAC energy consumption necessary to support the NZEH goals require a systems-oriented analysis approach that characterizes each element of energy consumption, identifies alternatives, and determines the most cost-effective combination of options. In particular, HVAC equipment must be developed that addresses the range of special needs of NZEH applications in the areas of reduced HVAC and water heating energy use, humidity control, ventilation, uniform comfort, and ease of zoning. In FY05 ORNL conducted an initial Stage 1 (Applied Research) scoping assessment of HVAC/WH systems options for future NZEHs to help DOE/BT identify and prioritize alternative approaches for further development. Eleven system concepts with central air distribution ducting and nine multi-zone systems were selected and their annual and peak demand performance estimated for five locations: Atlanta (mixed-humid), Houston (hot-humid), Phoenix (hot-dry), San Francisco (marine), and Chicago (cold). Performance was estimated by simulating the systems using the TRNSYS simulation engine (Solar Energy Laboratory et al. 2006) in two 1800-ft{sup 2} houses--a Building America (BA) benchmark house and a prototype NZEH taken from BEopt results at the take-off (or crossover) point (i.e., a house incorporating those design features such that further progress towards ZEH is through the addition of photovoltaic power sources, as determined by current BEopt analyses conducted by NREL). Results were summarized in a project report, 'HVAC Equipment Design options for Near-Zero-Energy Homes--A Stage 2 Scoping Assessment,' ORNL/TM-2005/194 (Baxter 2005). The 2005 study report describes the HVAC options considered, the ranking criteria used, and the system rankings by priority. Table 1 summarizes the energy savings potential of the highest scoring options from the 2005 study for all five locations.

  17. MODELING PARTICLE DEPOSITION ON HVAC HEAT EXCHANGERS

    E-Print Network [OSTI]

    in supplying ventilation and air conditioning. This paper explores mechanisms that cause particle deposition energy and indoor air quality degradation for heating, ventilating, and air conditioning (HVAC) systems

  18. Randomized Model Predictive Control for HVAC Systems Alessandra Parisio, Damiano Varagnolo, Daniel Risberg,

    E-Print Network [OSTI]

    Johansson, Karl Henrik

    temperature and CO2 con- centration levels. More specifically, we propose a random- ization technique Conditioning (HVAC) sys- tems play a fundamental role in maintaining acceptable ther- mal comfort and Indoor- pancy and weather conditions and uses them to build proba- bilistic constraints on the indoor

  19. An evaluation of three commercially available technologies forreal-time measurement of rates of outdoor airflow into HVAC systems

    SciTech Connect (OSTI)

    Fisk, William J.; Faulkner, David; Sullivan, Douglas P.

    2004-10-28

    During the last few years, new technologies have been introduced for real-time continuous measurement of the flow rates of outdoor air (OA) into HVAC systems; however, an evaluation of these measurements technologies has not previously been published. This document describes a test system and protocols developed for a controlled evaluation of these measurement technologies. The results of tests of three commercially available measurement technologies are also summarized. The test system and protocol were judged practical and very useful. The three commercially available measurement technologies should provide reasonably, e.g., 20%, accurate measurements of OA flow rates as long as air velocities are maintained high enough to produce accurately measurable pressure signals. In HVAC systems with economizer controls, to maintain the required air velocities the OA intake will need to be divided into two sections in parallel, each with a separate OA damper. All of the measurement devices had pressure drops that are likely to be judged acceptable. The influence of wind on the accuracy of these measurement technologies still needs to be evaluated.

  20. An evaluation of technologies for real-time measurement of rates of outdoor airflow into HVAC systems

    SciTech Connect (OSTI)

    Fisk, William J.; Faulkner, David; Sullivan, Douglas P.

    2004-09-01

    During the last few years, new technologies have been introduced for real-time continuous measurement of the flow rates of outdoor air (OA) into HVAC systems; however, an evaluation of these measurement technologies has not previously been published. This document describes a test system and protocols developed for a controlled evaluation of these measurement technologies. The results of tests of four commercially available measurement technologies and one prototype based on a new design are also summarized. The test system and protocol were judged practical and very useful. The series of tests identified three commercially available measurement technologies that should provide reasonably accurate measurements of OA flow rates as long as air velocities are maintained high enough to produce accurately measurable pressure signals. In HVAC systems with economizer controls, to maintain the required air velocities the OA intake will need to be divided into two sections in parallel, each with a separate OA damper. The errors in OA flow rates measured with the fourth commercially available measurement technology were 20% to 30% with horizontal probes but much larger with vertical probes. The new prototype measurement technology was the only one that appears suitable for measuring OA flow rates over their full range from 20% OA to 100% OA without using two separate OA dampers. All of the measurement devices had pressure drops that are likely to be judged acceptable. The influence of wind on the accuracy of these measurement technologies still needs to be evaluated.

  1. Measurements of Smoke Characteristics in HVAC Ducts 

    E-Print Network [OSTI]

    Wolin, Steven D; Ryder, Noah L; Leprince, Frederic; Milke, James; Mowrer, Frederick; Torero, Jose L

    2001-01-01

    The characteristics of smoke traveling in an HVAC duct have been observed along with the response of selected duct smoke detectors. The simulated HVAC system consists of a 9 m long duct, 0.45 m in diameter. An exhaust fan is placed at one end...

  2. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (http://www.hvac.okstate.edu).

    E-Print Network [OSTI]

    .D., and J. Cullin. 2008. Misconceptions Regarding Design of Ground-source Heat Pump Systems. Proceedings of Ground-source Heat Pump Systems Prof. Jeffrey Spitler1 & James Cullin1 1 School of Mechanical-405-744-7873. Email: spitler@okstate.edu, http://www.hvac.okstate.edu 1 Introduction Ground-source heat pump (GSHP

  3. Identifying Models of HVAC Systems Using Semiparametric Regression Anil Aswani, Neal Master, Jay Taneja, Virginia Smith, Andrew Krioukov, David Culler, and Claire Tomlin

    E-Print Network [OSTI]

    McAuliffe, Jon

    , and air-conditioning (HVAC) systems use a large amount of energy, and so they are an interesting area models that incorporate such nonlinearities. I. INTRODUCTION Heating, ventilation, and air-conditioning for efficiency improvements. The focus here is on the use of semiparametric regression to identify models, which

  4. CALIFORNIA ENERGY Large HVAC Building

    E-Print Network [OSTI]

    CALIFORNIA ENERGY COMMISSION Large HVAC Building Survey Information Database of Buildings over 100 Energy Systems: Productivity and Building Science Program. This program was funded by the California of Portland Energy Conservation, Inc. Project Management: Cathy Higgins, Program Director for New Buildings

  5. Research and Development Roadmap for Emerging HVAC Technologies

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    that focus on systems-level approach to HVAC sizingdesign 2 Develop an open-source building automation system to drive innovation 1 Develop optimized components for...

  6. Interdisciplinary Innovation and Vision in the HVAC 

    E-Print Network [OSTI]

    Hecker, T.

    2008-01-01

    potentials for optimizing costs can be found in the HVAC systems when calculated over the total Life-Cycle-Cost (LCC) of a building incorporating planning through to facility management. This requires an accurate plan specifying an efficient technical...

  7. Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating Ventilation and Air Conditioning (HVAC) system for the HIE-ISOLDE infrastructure

    E-Print Network [OSTI]

    2012-01-01

    Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating Ventilation and Air Conditioning (HVAC) system for the HIE-ISOLDE infrastructure

  8. Compression effects on pressure loss in flexible HVAC ducts

    E-Print Network [OSTI]

    Abushakra, Bass; Walker, Iain S.; Sherman, Max H.

    2002-01-01

    Flow Resistance of HVAC Air Ducts and Fittings. American= pitch of the flexible duct (longitudinal distance between49700. ACCA. 1995. Residential Duct Systems. Manual D. Air

  9. Modeling and Optimal Control Algorithm Design for HVAC Systems in Energy Efficient Buildings

    E-Print Network [OSTI]

    Maasoumy, Mehdi

    2014-01-01

    Litz. Simulation of thermal building behaviour in modelica.of the 2nd International Modelica Conference, volume 154.building behaviour using Modelica. Mathematical and Computer

  10. Flexibility of Commercial Building HVAC Fan as Ancillary Service for Smart Grid

    E-Print Network [OSTI]

    Maasoumy, Mehdi

    2013-01-01

    Efficient Building Control Systems, Smart Grid and AircraftCommercial Building HVAC Fan as Ancillary Service for Smart

  11. Co-design of Control Algorithm and Embedded Platformfor Building HVAC Systems

    E-Print Network [OSTI]

    Maasoumy, Mehdi; Zhu, Qi; Li, Cheng; Meggers, Forrest; Sangiovanni-Vincentelli, Alberto

    2013-01-01

    A design flow for building automation and control systems,”Development of building automation and control systems,”systems as part of a Building Automation System (BAS). The

  12. VOLUME 11, NUMBER 4 HVAC&R RESEARCH OCTOBER 2005 A Model for Annual Simulation of Standing

    E-Print Network [OSTI]

    be used as highly efficient ground heat exchangers in geothermal heat pump systems. This paper describes been in use in limited numbers since the advent of geothermal heat pump systems but are recently wells. An approach that uti- lizes an "enhanced" thermal conductivity to account for the natural

  13. Sentinel: Occupancy Based HVAC Actuation using Existing WiFi Infrastructure within Commercial Buildings

    E-Print Network [OSTI]

    Gupta, Rajesh

    , Control Keywords Sentinel, HVAC, occupancy, buildings, energy efficiency 1. INTRODUCTION Commercial.00. As a result, improving the energy-efficiency of building HVAC systems is key from both a cost saving

  14. Wireless Infrastructure for Performing Monitoring, Diagnostics, and Control HVAC and Other Energy-Using Systems in Small Commercial Buildings

    SciTech Connect (OSTI)

    Patrick O'Neill

    2009-06-30

    This project focused on developing a low-cost wireless infrastructure for monitoring, diagnosing, and controlling building systems and equipment. End users receive information via the Internet and need only a web browser and Internet connection. The system used wireless communications for: (1) collecting data centrally on site from many wireless sensors installed on building equipment, (2) transmitting control signals to actuators and (3) transmitting data to an offsite network operations center where it is processed and made available to clients on the Web (see Figure 1). Although this wireless infrastructure can be applied to any building system, it was tested on two representative applications: (1) monitoring and diagnostics for packaged rooftop HVAC units used widely on small commercial buildings and (2) continuous diagnosis and control of scheduling errors such as lights and equipment left on during unoccupied hours. This project developed a generic infrastructure for performance monitoring, diagnostics, and control, applicable to a broad range of building systems and equipment, but targeted specifically to small to medium commercial buildings (an underserved market segment). The proposed solution is based on two wireless technologies. The first, wireless telemetry, is used for cell phones and paging and is reliable and widely available. This risk proved to be easily managed during the project. The second technology is on-site wireless communication for acquiring data from sensors and transmitting control signals. The technology must enable communication with many nodes, overcome physical obstructions, operate in environments with other electrical equipment, support operation with on-board power (instead of line power) for some applications, operate at low transmission power in license-free radio bands, and be low cost. We proposed wireless mesh networking to meet these needs. This technology is relatively new and has been applied only in research and tests. This proved to be a major challenge for the project and was ultimately abandoned in favor of a directly wired solution for collecting sensor data at the building. The primary reason for this was the relatively short ranges at which we were able to effectively place the sensor nodes from the central receiving unit. Several different mesh technologies were attempted with similar results. Two hardware devices were created during the original performance period of the project. The first device, the WEB-MC, is a master control unit that has two radios, a CPU, memory, and serves as the central communications device for the WEB-MC System (Currently called the 'BEST Wireless HVAC Maintenance System' as a tentative commercial product name). The WEB-MC communicates with the local mesh network system via one of its antennas. Communication with the mesh network enables the WEB-MC to configure the network, send/receive data from individual motes, and serves as the primary mechanism for collecting sensor data at remote locations. The second antenna enables the WEB-MC to connect to a cellular network ('Long-Haul Communications') to transfer data to and from the NorthWrite Network Operations Center (NOC). A third 'all-in-one' hardware solution was created after the project was extended (Phase 2) and additional resources were provided. The project team leveraged a project funded by the State of Washington to develop a hardware solution that integrated the functionality of the original two devices. The primary reason for this approach was to eliminate the mesh network technical difficulties that severely limited the functionality of the original hardware approach. There were five separate software developments required to deliver the functionality needed for this project. These include the Data Server (or Network Operations Center), Web Application, Diagnostic Software, WEB-MC Embedded Software, Mote Embedded Software. Each of these developments was necessarily dependent on the others. This resulted in a challenging management task - requiring high bandwidth communications among

  15. Analysis of the Design of an HVAC System in a Public Building 

    E-Print Network [OSTI]

    Wei, P.; Shao, Z.; Chen, H.

    2006-01-01

    Based on an example of the design of air conditioning system for a public building, this paper analyzes the characteristics of similar buildings, and introduces the air conditioning system, ventilating system, and the fire control system...

  16. Total Quality Commissioning for HVAC Systems to Assure High Performance Throughout the Whole Life Cycle 

    E-Print Network [OSTI]

    Maisey, G.; Milestone, B.

    2005-01-01

    In this paper, life cycle cost analysis (LCCA) of waste heat operated vapour absorption air conditioning system (VARS) incorporated in a building cogeneration system is presented and discussed. The life cycle cost analysis (LCCA) based on present...

  17. Post-Retrocommissioning HVAC Operations Monitoring Using Enterprise-Wide energy Management System 

    E-Print Network [OSTI]

    Amarnani, N.; Roberts, B.; Choy, H.

    2007-01-01

    components/systems to diagnose and resolve root causes of operational deficiencies. During the implementation phase, new energy efficiency measures were installed, sequence of operations were optimized and functionally tested. System-level benchmark models...

  18. Life Cycle cost Analysis of Waste Heat Operated Absorption Cooling Systems for Building HVAC Applications 

    E-Print Network [OSTI]

    Saravanan, R.; Murugavel, V.

    2010-01-01

    In this paper, life cycle cost analysis (LCCA) of waste heat operated vapour absorption air conditioning system (VARS) incorporated in a building cogeneration system is presented and discussed. The life cycle cost analysis (LCCA) based on present...

  19. Improving efficiency of a vehicle HVAC system with comfort modeling, zonal design, and thermoelectric devices

    Office of Energy Efficiency and Renewable Energy (EERE)

    Discusses progress on thermal comfort modeling and detailed design, fabrication, and component/system-level testing of TE architecture

  20. Nuclear power reactor instrumentation systems handbook. Volume...

    Office of Scientific and Technical Information (OSTI)

    Nuclear power reactor instrumentation systems handbook. Volume 1 Citation Details In-Document Search Title: Nuclear power reactor instrumentation systems handbook. Volume 1 You...

  1. Commissioning of Building HVAC Systems for Improved Energy Performance: A Summary of Annex 40 Results 

    E-Print Network [OSTI]

    Visier, J. C.

    2004-01-01

    main achievements. These achievements can be split in 4 categories: 1) tools to manage the commissioning process, 2) manual commissioning tools, 3) approaches to use building energy management system to assist in building commissioning, 4) approaches...

  2. A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS

    E-Print Network [OSTI]

    operating conditions change. Poor control performance can lead to occupant discomfort in a building, greater it is controlling. Faults that lead to performance deterioration or a change in system behavior are often masked. In addition, the model acts as a reference of correct behavior, which facilitates the detection of faults

  3. FAULT DETECTION IN HVAC SYSTEMS USING MODEL-BASED FEEDFORWARD CONTROL

    E-Print Network [OSTI]

    operating conditions change. Poor control performance can lead to occupant discomfort in the treated the process it is controlling. Faults that lead to performance deterioration, or a change in system behavior. The model used in the feedforward controller acts as a baseline of correct behavior, and facilitates

  4. Re-Commissioning of the CAMET HVAC System: A Successful Case Study 

    E-Print Network [OSTI]

    Andre, P.; Cuevas, C.; Lacote, P.; Lebrun, J.

    2003-01-01

    conditioning system. Focus is given here to the so-called “recommissioning” and the proposed principles are illustrated by reference to a specific case study: the “CAMET” building. The "CA-MET" is a new ministry office building, designed for an occupancy...

  5. Methodology to Analyze the Sensitivity of Building Energy Consumption to HVAC System Sensor Error 

    E-Print Network [OSTI]

    Ma, Liang

    2012-02-14

    (MIL-HDBK-338B, 2008). The report entitled ?Failure Mode/Mechanism Distribution 1997? offers abundant failure mode data defined alternatively for equipment, actuators, etc. In this report, short, open and drift are all considered failure modes..., 2010). The least common failure mode is the shorted circuit, which comprises 15% of thermistor failures. The Electronic Reliability Design Handbook (MIL-HDBK-338B, 2008) uses a different classification system for thermistor failure modes classifying...

  6. Grundfos HVAC OEM Efficient water hydraulics

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    .7 mio. integrated water circuits are running already in boiler systems . Efficient water hydraulics HVAC complexity ·20 years of experience in hydraulics for the Boiler System industry. ·Key success factor is our of boiler capacity the flow requirements for heat pumps are up to 4 times bigger. With UPML GEO we

  7. Model Predictive Control of HVAC Systems: Implementation and Testing at the University of California, Merced

    SciTech Connect (OSTI)

    Haves, Phillip; Hencey, Brandon; Borrell, Francesco; Elliot, John; Ma, Yudong; Coffey, Brian; Bengea, Sorin; Wetter, Michael

    2010-06-29

    A Model Predictive Control algorithm was developed for the UC Merced campus chilled water plant. Model predictive control (MPC) is an advanced control technology that has proven successful in the chemical process industry and other industries. The main goal of the research was to demonstrate the practical and commercial viability of MPC for optimization of building energy systems. The control algorithms were developed and implemented in MATLAB, allowing for rapid development, performance, and robustness assessment. The UC Merced chilled water plant includes three water-cooled chillers and a two million gallon chilled water storage tank. The tank is charged during the night to minimize on-peak electricity consumption and take advantage of the lower ambient wet bulb temperature. The control algorithms determined the optimal chilled water plant operation including chilled water supply (CHWS) temperature set-point, condenser water supply (CWS) temperature set-point and the charging start and stop times to minimize a cost function that includes energy consumption and peak electrical demand over a 3-day prediction horizon. A detailed model of the chilled water plant and simplified models of the buildings served by the plant were developed using the equation-based modeling language Modelica. Steady state models of the chillers, cooling towers and pumps were developed, based on manufacturers performance data, and calibrated using measured data collected and archived by the control system. A detailed dynamic model of the chilled water storage tank was also developed and calibrated. Simple, semi-empirical models were developed to predict the temperature and flow rate of the chilled water returning to the plant from the buildings. These models were then combined and simplified for use in a model predictive control algorithm that determines the optimal chiller start and stop times and set-points for the condenser water temperature and the chilled water supply temperature. The report describes the development and testing of the algorithm and evaluates the resulting performance, concluding with a discussion of next steps in further research. The experimental results show a small improvement in COP over the baseline policy but it is difficult to draw any strong conclusions about the energy savings potential for MPC with this system only four days of suitable experimental data were obtained once correct operation of the MPC system had been achieved. These data show an improvement in COP of 3.1% {+-} 2.2% relative to a baseline established immediately prior to the period when the MPC was run in its final form. This baseline includes control policy improvements that the plant operators learned by observing the earlier implementations of MPC, including increasing the temperature of the water supplied to the chiller condensers from the cooling towers. The process of data collection and model development, necessary for any MPC project, resulted in the team uncovering various problems with the chilled water system. Although it is difficult to quantify the energy savings resulting from these problems being remedied, they were likely on the same order as the energy savings from the MPC itself. Although the types of problems uncovered and the level of energy savings may differ significantly from other projects, some of the benefits of detecting and diagnosing problems are expected from the use of MPC for any chilled water plant. The degree of chiller loading was found to be a key factor for efficiency. It is more efficient to operate the chillers at or near full load. In order to maximize the chiller load, one would maximize the temperature difference across chillers and the chilled water flow rate through the chillers. Thus, the CHWS set-point and the chilled water flow-rate can be used to limit the chiller loading to prevent chiller surging. Since the flow rate has an upper bound and the CHWS set point has a lower bound, the chiller loading is constrained and often determined by the chilled water return temperature (CHWR). The CHWR temperature

  8. Advanced control strategies for HVAC&R systems—An overview: Part II: Soft and fusion control

    SciTech Connect (OSTI)

    D. Subbaram Naidu; Craig G. Rieger

    2011-04-01

    A chronological overview of the advanced control strategies for HVAC&R is presented. The overview focuses on hard-computing or control techniques, such as proportional-integral-derivative, optimal, nonlinear, adaptive, and robust; soft-computing or control techniques, such as neural networks, fuzzy logic, genetic algorithms; and the fusion or hybrid of hard and soft control techniques. Part I focused on hardcontrol strategies; Part II focuses on soft and fusion control and some future directions in HVA&R research. This overview is not intended to be an exhaustive survey on this topic, and any omissions of other works is purely unintentional.

  9. Analysis and characterization of ancillary service demand response strategies for variable air volume HVAC systems

    E-Print Network [OSTI]

    Blum, David H. (David Henry)

    2013-01-01

    Output variability and prediction difficulties with respect to solar and wind electricity resources increase the requirement of grid-scale reserve capacity and add strain to existing firm generators used for reserves and ...

  10. Demonstration of HVAC chiller control for power grid frequency regulation

    E-Print Network [OSTI]

    Su, Po-An (Po-An Leo)

    2015-01-01

    Secondary frequency regulation is a necessary electric grid ancillary service that balances electric power system supply and demand on short time intervals of seconds to minutes. Commercial HVAC chillers may be well ...

  11. A Quasi-Dynamic HVAC and Building Simulation Methodology 

    E-Print Network [OSTI]

    Davis, Clinton Paul

    2012-07-16

    This thesis introduces a quasi-dynamic building simulation methodology which complements existing building simulators by allowing transient models of HVAC (heating, ventilating and air-conditioning) systems to be created in an analogous way...

  12. Automotive Thermoelectric Generators and HVAC | Department of...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Generators and HVAC Automotive Thermoelectric Generators and HVAC Provides overview of DOE-supported projects in automotive thermoelectric generators and heatersair conditioners...

  13. The Impact of Uncertain Physical Parameters on HVAC Demand Response

    SciTech Connect (OSTI)

    Sun, Yannan; Elizondo, Marcelo A.; Lu, Shuai; Fuller, Jason C.

    2014-03-01

    HVAC units are currently one of the major resources providing demand response (DR) in residential buildings. Models of HVAC with DR function can improve understanding of its impact on power system operations and facilitate the deployment of DR technologies. This paper investigates the importance of various physical parameters and their distributions to the HVAC response to DR signals, which is a key step to the construction of HVAC models for a population of units with insufficient data. These parameters include the size of floors, insulation efficiency, the amount of solid mass in the house, and efficiency of the HVAC units. These parameters are usually assumed to follow Gaussian or Uniform distributions. We study the effect of uncertainty in the chosen parameter distributions on the aggregate HVAC response to DR signals, during transient phase and in steady state. We use a quasi-Monte Carlo sampling method with linear regression and Prony analysis to evaluate sensitivity of DR output to the uncertainty in the distribution parameters. The significance ranking on the uncertainty sources is given for future guidance in the modeling of HVAC demand response.

  14. Initial Business Case Analysis of Two Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes - Update to Include Evaluation of Impact of Including a Humidifier Option

    SciTech Connect (OSTI)

    Baxter, Van D

    2007-02-01

    The long range strategic goal of the Department of Energy's Building Technologies (DOE/BT) Program is to create, by 2020, technologies and design approaches that enable the construction of net-zero energy homes at low incremental cost (DOE/BT 2005). A net zero energy home (NZEH) is a residential building with greatly reduced needs for energy through efficiency gains, with the balance of energy needs supplied by renewable technologies. While initially focused on new construction, these technologies and design approaches are intended to have application to buildings constructed before 2020 as well resulting in substantial reduction in energy use for all building types and ages. DOE/BT's Emerging Technologies (ET) team is working to support this strategic goal by identifying and developing advanced heating, ventilating, air-conditioning, and water heating (HVAC/WH) technology options applicable to NZEHs. In FY05 ORNL conducted an initial Stage 1 (Applied Research) scoping assessment of HVAC/WH systems options for future NZEHs to help DOE/BT identify and prioritize alternative approaches for further development. Eleven system concepts with central air distribution ducting and nine multi-zone systems were selected and their annual and peak demand performance estimated for five locations: Atlanta (mixed-humid), Houston (hot-humid), Phoenix (hot-dry), San Francisco (marine), and Chicago (cold). Performance was estimated by simulating the systems using the TRNSYS simulation engine (Solar Energy Laboratory et al. 2006) in two 1800-ft{sup 2} houses--a Building America (BA) benchmark house and a prototype NZEH taken from BEopt results at the take-off (or crossover) point (i.e., a house incorporating those design features such that further progress towards ZEH is through the addition of photovoltaic power sources, as determined by current BEopt analyses conducted by NREL). Results were summarized in a project report, HVAC Equipment Design options for Near-Zero-Energy Homes--A Stage 2 Scoping Assessment, ORNL/TM-2005/194 (Baxter 2005). The 2005 study report describes the HVAC options considered, the ranking criteria used, and the system rankings by priority. In 2006, the two top-ranked options from the 2005 study, air-source and ground-source versions of a centrally ducted integrated heat pump (IHP) system, were subjected to an initial business case study. The IHPs were subjected to a more rigorous hourly-based assessment of their performance potential compared to a baseline suite of equipment of legally minimum efficiency that provided the same heating, cooling, water heating, demand dehumidification, and ventilation services as the IHPs. Results were summarized in a project report, Initial Business Case Analysis of Two Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes, ORNL/TM-2006/130 (Baxter 2006a). The present report is an update to that document which summarizes results of an analysis of the impact of adding a humidifier to the HVAC system to maintain minimum levels of space relative humidity (RH) in winter. The space RH in winter has direct impact on occupant comfort and on control of dust mites, many types of disease bacteria, and 'dry air' electric shocks. Chapter 8 in ASHRAE's 2005 Handbook of Fundamentals (HOF) suggests a 30% lower limit on RH for indoor temperatures in the range of {approx}68-69F based on comfort (ASHRAE 2005). Table 3 in chapter 9 of the same reference suggests a 30-55% RH range for winter as established by a Canadian study of exposure limits for residential indoor environments (EHD 1987). Harriman, et al (2001) note that for RH levels of 35% or higher, electrostatic shocks are minimized and that dust mites cannot live at RH levels below 40%. They also indicate that many disease bacteria life spans are minimized when space RH is held within a 30-60% range. From the foregoing it is reasonable to assume that a winter space RH range of 30-40% would be an acceptable compromise between comfort considerations and limitation of growth rates for dust mites and many bacteria. In addition it reports som

  15. HVAC Cabinet Air Leakage Test Method - Building America Top Innovation...

    Energy Savers [EERE]

    HVAC Cabinet Air Leakage Test Method - Building America Top Innovation HVAC Cabinet Air Leakage Test Method - Building America Top Innovation While HVAC installers have improved...

  16. Chapter 19: HVAC Controls (DDC/EMS/BAS) Evaluation Protocol

    SciTech Connect (OSTI)

    Romberger, J.

    2014-11-01

    The HVAC Controls Evaluation Protocol is designed to address evaluation issues for direct digital controls/energy management systems/building automation systems (DDC/EMS/BAS) that are installed to control heating, ventilation, and air-conditioning (HVAC) equipment in commercial and institutional buildings. (This chapter refers to the DDC/EMS/BAS measure as HVAC controls.) This protocol may also be applicable to industrial facilities such as clean rooms and labs, which have either significant HVAC equipment or spaces requiring special environmental conditions. This protocol addresses only HVAC-related equipment and the energy savings estimation methods associated with installing such control systems as an energy efficiency measure. The affected equipment includes: Air-side equipment (air handlers, direct expansion systems, furnaces, other heating- and cooling-related devices, terminal air distribution equipment, and fans); Central plant equipment (chillers, cooling towers, boilers, and pumps). These controls may also operate or affect other end uses, such as lighting, domestic hot water, irrigation systems, and life safety systems such as fire alarms and other security systems. Considerable nonenergy benefits, such as maintenance scheduling, system component troubleshooting, equipment failure alarms, and increased equipment lifetime, may also be associated with these systems. When connected to building utility meters, these systems can also be valuable demand-limiting control tools. However, this protocol does not evaluate any of these additional capabilities and benefits.

  17. Review of Pre- and Post-1980 Buildings in CBECS - HVAC Equipment

    SciTech Connect (OSTI)

    Winiarski, David W.; Jiang, Wei; Halverson, Mark A.

    2006-12-01

    PNNL was tasked by DOE to look at HVAC systems and equipment for Benchmark buildings based on 2003 CBECS data. This white paper summarizes the results of PNNL’s analysis of 2003 CBECS data and provides PNNL’s recommendations for HVAC systems and equipment for use in the Benchmark buildings.

  18. Lighting/HVAC interactions and their effects on annual and peak HVAC requirements in commercial buildings

    SciTech Connect (OSTI)

    Sezgen, A.O.; Huang, Y.J.

    1994-08-01

    Lighting measures is one effective strategy for reducing energy use in commercial buildings. Reductions in lighting energy have secondary effects on cooling/heating energy consumption and peak HVAC requirements; in general, they increase the heating and decrease cooling requirements of a building. Net change in a building`s annual and peak energy requirements, however, is difficult to quantify and depends on building characteristics, operating conditions, climate. This paper characterizes impacts of lighting/HVAC interactions on annual and peak heating/cooling requirements of prototypical US commercial buildings through computer simulations using DOE-2.1E building energy analysis program. Ten building types of two vintages and nine climates are chosen to represent the US commercial building stock. For each combination, a prototypical building is simulated with two lighting power densities, and resultant changes in heating and cooling loads are recorded. Simple concepts of Lighting Coincidence Factors are used to describe the observed interactions between lighting and HVAC requirements. (Coincidence Factor (CF) is ratio of changes in HVAC loads to those in lighting loads, where load is either annual or peak load). The paper presents tables of lighting CF for major building types and climates. These parameters can be used for regional or national cost/benefit analyses of lighting- related policies and utility DSM programs. Using Annual CFs and typical efficiencies for heating and cooling systems, net changes in space conditioning energy use from a lighting measure can be calculated. Similarly, Demand CFs can be used to estimate the changes in HVAC sizing, which can then be converted to changes in capital outlay using standard-design curves; or they can be used to estimate coincident peak reductions for the analysis of the utility`s avoided costs. Results from use of these tables are meaningful only when they involve a significantly large number of buildings.

  19. Multi-carrier Signal Transmission through HVAC Ducts: Experimental Results for Channel Capacity

    E-Print Network [OSTI]

    Stancil, Daniel D.

    Multi-carrier Signal Transmission through HVAC Ducts: Experimental Results for Channel Capacity) ducts based on multi-carrier transmission technique and mea- sured channel frequency responses in the 2 through a building HVAC duct system demonstrate the ability to transmit with a spectral efficiency of 3

  20. Building America Top Innovations 2014 Profile: HVAC Cabinet Air Leakage Test Method

    SciTech Connect (OSTI)

    none,

    2014-11-01

    This 2014 Top Innovation profile describes Building America-funded research by teams and national laboratories that resulted in the development of an ASHRAE standard and a standardized testing method for testing the air leakage of HVAC air handlers and furnace cabinets and has spurred equipment manufacturers to tighten the cabinets they use for residential HVAC systems.

  1. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, VOL. 51, NO. 5, MAY 2003 945 Propagation Model for the HVAC Duct as a

    E-Print Network [OSTI]

    Hannaford, Blake

    for the HVAC Duct as a Communication Channel Pavel V. Nikitin, Member, IEEE, Daniel D. Stancil, Senior Member (HVAC) ducts in buildings are typically hollow metal pipes which can be used as waveguides to carry such a communication system. This paper presents a propagation model for a straight HVAC duct terminated at both ends

  2. Integrated Ice Storage/Sprinkler HVAC System Sharply Cuts Energy Costs and Air-Distribution First Costs 

    E-Print Network [OSTI]

    Meckler, G.

    1986-01-01

    by distributing a small quantity (0.1 to 0.2 cfm/sq ft) of very dry, 40°F primary air. All dehumidification is handled by the ice-chilled primary air, which is distributed in variable, volume, determined by the space dehumidification requirement, to fan-coil...

  3. Pedernales Electric Cooperative- HVAC Rebate Program

    Broader source: Energy.gov [DOE]

    Pedernales Electric Cooperative offers equipment rebates to its members who install energy efficient HVAC equipment. Eligible equipment includes:

  4. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    Simulation and Its Implementation in EnergyPlus. Proceedings of Building Simulation '99, Vol. 3, pp. 1245 IMPLEMENTATION IN ENERGYPLUS Daniel E Fisher1 , Russell D. Taylor2 , Fred Buhl3 , Richard J Liesen2 , and Richard K Strand4 ABSTRACT This paper presents the new EnergyPlus HVAC simulation environment, which differs

  5. OPTIMUM DUCT DESIGN FOR VARIABLE AIR VOLUME SYSTEMS

    E-Print Network [OSTI]

    OPTIMUM DUCT DESIGN FOR VARIABLE AIR VOLUME SYSTEMS By TAECHEOL KIM Master of Science Oklahoma May, 2001 #12;ii OPTIMUM DUCT DESIGN FOR VARIABLE AIR VOLUME SYSTEMS Thesis Approved Volume Systems ............................................. 5 1.2.2. Duct Design Methods

  6. Initial Business Case Analysis of Two Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes -- Update to Include Analyses of an Economizer Option and Alternative Winter Water Heating Control Option

    SciTech Connect (OSTI)

    Baxter, Van D

    2006-12-01

    The long range strategic goal of the Department of Energy's Building Technologies (DOE/BT) Program is to create, by 2020, technologies and design approaches that enable the construction of net-zero energy homes at low incremental cost (DOE/BT 2005). A net zero energy home (NZEH) is a residential building with greatly reduced needs for energy through efficiency gains, with the balance of energy needs supplied by renewable technologies. While initially focused on new construction, these technologies and design approaches are intended to have application to buildings constructed before 2020 as well resulting in substantial reduction in energy use for all building types and ages. DOE/BT's Emerging Technologies (ET) team is working to support this strategic goal by identifying and developing advanced heating, ventilating, air-conditioning, and water heating (HVAC/WH) technology options applicable to NZEHs. Although the energy efficiency of heating, ventilating, and air-conditioning (HVAC) equipment has increased substantially in recent years, new approaches are needed to continue this trend. Dramatic efficiency improvements are necessary to enable progress toward the NZEH goals, and will require a radical rethinking of opportunities to improve system performance. The large reductions in HVAC energy consumption necessary to support the NZEH goals require a systems-oriented analysis approach that characterizes each element of energy consumption, identifies alternatives, and determines the most cost-effective combination of options. In particular, HVAC equipment must be developed that addresses the range of special needs of NZEH applications in the areas of reduced HVAC and water heating energy use, humidity control, ventilation, uniform comfort, and ease of zoning. In FY05 ORNL conducted an initial Stage 1 (Applied Research) scoping assessment of HVAC/WH systems options for future NZEHs to help DOE/BT identify and prioritize alternative approaches for further development. Eleven system concepts with central air distribution ducting and nine multi-zone systems were selected and their annual and peak demand performance estimated for five locations: Atlanta (mixed-humid), Houston (hot-humid), Phoenix (hot-dry), San Francisco (marine), and Chicago (cold). Performance was estimated by simulating the systems using the TRNSYS simulation engine (Solar Energy Laboratory et al. 2006) in two 1800-ft{sup 2} houses--a Building America (BA) benchmark house and a prototype NZEH taken from BEopt results at the take-off (or crossover) point (i.e., a house incorporating those design features such that further progress towards ZEH is through the addition of photovoltaic power sources, as determined by current BEopt analyses conducted by NREL). Results were summarized in a project report, HVAC Equipment Design options for Near-Zero-Energy Homes--A Stage 2 Scoping Assessment, ORNL/TM-2005/194 (Baxter 2005). The 2005 study report describes the HVAC options considered, the ranking criteria used, and the system rankings by priority. In 2006, the two top-ranked options from the 2005 study, air-source and ground-source versions of an integrated heat pump (IHP) system, were subjected to an initial business case study. The IHPs were subjected to a more rigorous hourly-based assessment of their performance potential compared to a baseline suite of equipment of legally minimum efficiency that provided the same heating, cooling, water heating, demand dehumidification, and ventilation services as the IHPs. Results were summarized in a project report, Initial Business Case Analysis of Two Integrated Heat Pump HVAC Systems for Near-Zero-Energy Homes, ORNL/TM-2006/130 (Baxter 2006). The present report is an update to that document. Its primary purpose is to summarize results of an analysis of the potential of adding an outdoor air economizer operating mode to the IHPs to take advantage of free cooling (using outdoor air to cool the house) whenever possible. In addition it provides some additional detail for an alternative winter water heating/space heating (WH/S

  7. Indirect Benefits (Increased Roof Life and HVAC Savings) from a Solar PV System at the San José Convention Center

    Office of Energy Efficiency and Renewable Energy (EERE)

    The City of San José is considering the installation of a solar photovoltaic (PV) system on the roof of the San José Convention Center. The installation would be on a lower section of the roof covering approximately 21,000 ft2. To assist city staff in making a decision on the PV installation, the Department of Energy Tiger Team has investigated potential indirect benefits of installing a solar PV system on the Convention Center roof. The indirect benefits include potential increase in roof life, as well as potential reduced heating and cooling load in the building due to roof shading from the PV system.

  8. Development of an Automated Fault Detection and Diagnostic Tool for Unitary HVAC Systems at Industrial Energy Audits 

    E-Print Network [OSTI]

    Parikh, Priyam

    2014-10-30

    their repair with a monetary value without the use of a quick tool. Existing methods and tools require system specific models or manufacturer’s map models that are not easily available to energy auditors. The proposed automated fault detection and diagnostic...

  9. Application of Various HVAC Simulation Programs and Visual Tools to Commissioning 

    E-Print Network [OSTI]

    Zheng, M.; Pan, S.

    2007-01-01

    Various existing HVAC system simulation programs and visualization tools are considered to be potentially powerful tools for commissioning. Although not originally developed as commissioning tools, these programs facilitate the confirmation...

  10. 1999 Commercial Buildings Characteristics--HVAC Conservation...

    U.S. Energy Information Administration (EIA) Indexed Site

    Center at (202) 586-8800. Energy Information Administration Commercial Buildings Energy Consumption Survey Those commercial buildings that used HVAC conservation features...

  11. Columbia Water & Light- Residential HVAC Rebates

    Broader source: Energy.gov [DOE]

    Columbia Water & Light (CWL) provides residential customers with rebates on energy efficient HVAC equipment. Customers should submit the mechanical permit from a Protective Inspection, a copy...

  12. Building America Expert Meeting: Transitioning Traditional HVAC...

    Energy Savers [EERE]

    validate the general business models for traditional HVAC companies and whole house energy upgrade companies Review preliminary findings on the differences between the structure...

  13. Energy Department Releases Roadmaps on HVAC Technologies, Water...

    Office of Environmental Management (EM)

    Energy Department Releases Roadmaps on HVAC Technologies, Water Heating, Appliances, and Low-GWP Refrigerants Energy Department Releases Roadmaps on HVAC Technologies, Water...

  14. Promising Technology: Variable-Air-Volume Ventilation System

    Broader source: Energy.gov [DOE]

    Variable-air-volume (VAV) ventilation saves energy compared to a constant-air-volume (CAV) ventilation system, mainly by reducing energy consumption associated with fans.

  15. HVAC component data modeling using industry foundation classes

    SciTech Connect (OSTI)

    Bazjanac, Vladimir; Forester, James; Haves, Philip; Sucic, Darko; Xu, Peng

    2002-07-01

    The Industry Foundation Classes (IFC) object data model of buildings is being developed by the International Alliance for Interoperability (IAI). The aim is to support data sharing and exchange in the building and construction industry across the life-cycle of a building. This paper describes a number of aspects of a major extension of the HVAC part of the IFC data model. First is the introduction of a more generic approach for handling HVAC components. This includes type information, which corresponds to catalog data, occurrence information, which defines item-specific attributes such as location and connectivity, and performance history information, which documents the actual performance of the component instance over time. Other IFC model enhancements include an extension of the connectivity model used to specify how components forming a system can be traversed and the introduction of time-based data streams. This paper includes examples of models of particular types of HVAC components, such as boilers and actuators, with all attributes included in the definitions. The paper concludes by describing the on-going process of model testing, implementation and integration into the complete IFC model and how the model can be used by software developers to support interoperability between HVAC-oriented design and analysis tools.

  16. A standard simulation testbed for the evaluation of control algorithms & strategies related to variable air volume HVAC systems

    E-Print Network [OSTI]

    DeSimone, Mark

    1995-01-01

    The parameters for a dynamic, computer simulation model were developed. The parameters characterize the physical and geometric properties of a building shell, the internal and external building loads, the buildings secondary ...

  17. Quantitative Methods for Comparing Different HVAC Control Schemes

    E-Print Network [OSTI]

    Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

    2012-01-01

    Experimentally comparing the energy usage and comfort characteristics of different controllers in heating, ventilation, and air-conditioning (HVAC) systems is difficult because variations in weather and occupancy conditions preclude the possibility of establishing equivalent experimental conditions across the order of hours, days, and weeks. This paper is concerned with defining quantitative metrics of energy usage and occupant comfort, which can be computed and compared in a rigorous manner that is capable of determining whether differences between controllers are statistically significant in the presence of such environmental fluctuations. Experimental case studies are presented that compare two alternative controllers (a schedule controller and a hybrid system learning-based model predictive controller) to the default controller in a building-wide HVAC system. Lastly, we discuss how our proposed methodology may also be able to quantify the efficiency of other building automation systems.

  18. Realt-Time Building Occupancy Sensing for Supporting Demand Driven HVAC Operations 

    E-Print Network [OSTI]

    Ekwevugbe, T.; Brown, N.; Pakka, V.

    2013-01-01

    use. Previous research have proposed up to 56% HVAC related energy savings with improvements in operation and management of HVAC systems (Sun et al., 2011, Tachwali et al., 2007). Real- time building occupancy sensing is useful for efficient.... The area enjoys good natural lighting due to its large side windows, although it is shaded from the direct effect of the sun by an adjacent part of the building. It is ventilated with three glazed roof vents. The vents are controlled together by room...

  19. Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues

    SciTech Connect (OSTI)

    Wang, Liping; Hong, Tianzhen

    2013-01-01

    Almost half of the total energy used in the U.S. buildings is consumed by heating, ventilation and air conditionings (HVAC) according to EIA statistics. Among various driving factors to energy performance of building, operations and maintenance play a significant role. Many researches have been done to look at design efficiencies and operational controls for improving energy performance of buildings, but very few study the impacts of HVAC systems maintenance. Different practices of HVAC system maintenance can result in substantial differences in building energy use. If a piece of HVAC equipment is not well maintained, its performance will degrade. If sensors used for control purpose are not calibrated, not only building energy usage could be dramatically increased, but also mechanical systems may not be able to satisfy indoor thermal comfort. Properly maintained HVAC systems can operate efficiently, improve occupant comfort, and prolong equipment service life. In the paper, maintenance practices for HVAC systems are presented based on literature reviews and discussions with HVAC engineers, building operators, facility managers, and commissioning agents. We categorize the maintenance practices into three levels depending on the maintenance effort and coverage: 1) proactive, performance-monitored maintenance; 2) preventive, scheduled maintenance; and 3) reactive, unplanned or no maintenance. A sampled list of maintenance issues, including cooling tower fouling, boiler/chiller fouling, refrigerant over or under charge, temperature sensor offset, outdoor air damper leakage, outdoor air screen blockage, outdoor air damper stuck at fully open position, and dirty filters are investigated in this study using field survey data and detailed simulation models. The energy impacts of both individual maintenance issue and combined scenarios for an office building with central VAV systems and central plant were evaluated by EnergyPlus simulations using three approaches: 1) direct modeling with EnergyPlus, 2) using the energy management system feature of EnergyPlus, and 3) modifying EnergyPlus source code. The results demonstrated the importance of maintenance for HVAC systems on energy performance of buildings. The research is intended to provide a guideline to help practitioners and building operators to gain the knowledge of maintaining HVAC systems in efficient operations, and prioritize HVAC maintenance work plan. The paper also discusses challenges of modeling building maintenance issues using energy simulation programs.

  20. Higher Efficiency HVAC Motors | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    and the world leader in HVAC and refrigeration solutions. QM Power's Parallel Path Magnetic Technology(tm) (PPMT(tm)) uses permanent magnets in a novel yet simple magnetic...

  1. Predicting particle deposition on HVAC heat exchangers

    E-Print Network [OSTI]

    Siegel, J A; Nazaroff, William W

    2003-01-01

    Processing 75 (1), 121-127. Muyshondt, A. , Nutter, D. ,Bott and Bemrose, 1983; Muyshondt et al. , 1998). However,HVAC heat exchanger fouling (Muyshondt et al. , 1998). It is

  2. Better Buildings Neighborhood Program Business Models Guide: HVAC Contractor Business Model Conclusion

    Broader source: Energy.gov [DOE]

    Better Buildings Neighborhood Program Business Models Guide: HVAC Contractor Business Model Conclusion, Summary of HVAC Contractor Insights.

  3. VARIABLE SPEED INTEGRATED INTELLIGENT HVAC BLOWER

    SciTech Connect (OSTI)

    Shixiao Wang; Herman Wiegman; Wilson Wu; John Down; Luana Iorio; Asha Devarajan; Jing Wang; Ralph Carl; Charlie Stephens; Jeannine Jones; Paul Szczesny

    2001-11-14

    This comprehensive topical report discusses the key findings in the development of a intelligent integrated blower for HVAC applications. The benefits of rearward inclined blades over that of traditional forward inclined blades is well documented and a prototype blower design is presented. A comparison of the proposed blower to that of three typical units from the industry is presented. The design of the blower housing is also addressed and the impact of size limitations on static efficiency is discussed. Issues of air flow controllability in the rearward inclined blower is addressed and a solution to this problem is proposed. Several motor design options are discussed including inside-out radial flux designs and novel axial flux designs, all are focused on the various blower needs. The control of the motor-blower and airflow through the use of a high density inverter stage and modern digital signal processor is presented. The key technical challenges of the approach are discussed. The use of the motor as a sensor in the larger heating/ventilating system is also discussed. Diagnostic results for both the motor itself and the blower system are presented.

  4. CIRMIS Data system. Volume 2. Program listings

    SciTech Connect (OSTI)

    Friedrichs, D.R.

    1980-01-01

    The Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program is developing and applying the methodology for assessing the far-field, long-term post-closure safety of deep geologic nuclear waste repositories. AEGIS is being performed by Pacific Northwest Laboratory (PNL) under contract with the Office of Nuclear Waste Isolation (OWNI) for the Department of Energy (DOE). One task within AEGIS is the development of methodology for analysis of the consequences (water pathway) from loss of repository containment as defined by various release scenarios. Analysis of the long-term, far-field consequences of release scenarios requires the application of numerical codes which simulate the hydrologic systems, model the transport of released radionuclides through the hydrologic systems, model the transport of released radionuclides through the hydrologic systems to the biosphere, and, where applicable, assess the radiological dose to humans. The various input parameters required in the analysis are compiled in data systems. The data are organized and prepared by various input subroutines for utilization by the hydraulic and transport codes. The hydrologic models simulate the groundwater flow systems and provide water flow directions, rates, and velocities as inputs to the transport models. Outputs from the transport models are basically graphs of radionuclide concentration in the groundwater plotted against time. After dilution in the receiving surface-water body (e.g., lake, river, bay), these data are the input source terms for the dose models, if dose assessments are required.The dose models calculate radiation dose to individuals and populations. CIRMIS (Comprehensive Information Retrieval and Model Input Sequence) Data System is a storage and retrieval system for model input and output data, including graphical interpretation and display. This is the second of four volumes of the description of the CIRMIS Data System.

  5. MODELING AND SIMULATION OF HVAC FAULTS IN ENERGYPLUS

    E-Print Network [OSTI]

    Basarkar, Mangesh

    2013-01-01

    http://www.eia.doe.gov/emeu/cbecs/ EnergyPlus. 2011, http://of HVAC Results in EnergyPlus Mangesh Basarkar, XiufengOF HVAC FAULTS IN ENERGYPLUS Mangesh Basarkar, Xiufeng Pang,

  6. Cooling and Dehumidification HVAC Technology for 1990s

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    Desiccant Cooling and Dehumidification HVAC Technology for 1990s HVAC: Heating, Ventilation, and Air Conditioning Desiccant Cooling Group Solar Energy Research Institute Golden, Colorado #12;Table of Contents * Background and Fundamentals * SERI Desiccant Research * Status of Desiccant Technology * Future

  7. Energy Savings Potential and RD&D Opportunities for Non-Vapor-Compression HVAC Technologies

    SciTech Connect (OSTI)

    none,

    2014-03-01

    While vapor-compression technologies have served heating, ventilation, and air-conditioning (HVAC) needs very effectively, and have been the dominant HVAC technology for close to 100 years, the conventional refrigerants used in vapor-compression equipment contribute to global climate change when released to the atmosphere. This Building Technologies Office report: --Identifies alternatives to vapor-compression technology in residential and commercial HVAC applications --Characterizes these technologies based on their technical energy savings potential, development status, non-energy benefits, and other factors affecting end-user acceptance and their ability to compete with conventional vapor-compression systems --Makes specific research, development, and deployment (RD&D) recommendations to support further development of these technologies, should DOE choose to support non-vapor-compression technology further.

  8. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    In ENERGYPLUS. Proceedings of Building Simulation '99, Volume 2: 653-660. #12;1 ENHANCING AND EXTENDING THE CAPABILITIES OF THE BUILDING HEAT BALANCE SIMULATION TECHNIQUE FOR USE IN ENERGYPLUS Richard Strand, School achieved by the team of researchers developing the EnergyPlus program for the United States Department

  9. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    .J. Huang, A.E. Erdem. ENERGYPLUS, A New-Generation Building Energy Simulation Program. Proceedings of Building Simulation '99, Volume 1: 81-88. #12;1 ENERGYPLUS, A NEW-GENERATION BUILDING ENERGY SIMULATION simulation tool, EnergyPlus, building on the capabilities and features of BLAST and DOE-2. This paper focuses

  10. Vehicle & Systems Simulation & Testing

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    EV - EVSE Interoperability Advanced Charging Grid Integration Vehicle Systems Optimization Fast and Wireless Charging Grid Integration Load Reduction, HVAC, & Preconditioning...

  11. This paper was downloaded from the Oklahoma State University Building and Environmental Thermal Systems Research Group website, www.hvac.okstate.edu.

    E-Print Network [OSTI]

    design flow velocities on system performance of ground source heat pump systems in cold climates. ASHRAE Exchanger Design Flow Velocities on System Performance of Ground Source Heat Pump Systems in Cold Climates guidelines for ground source heat pump (GSHP) systems provide recommendations for minimum and maximum flow

  12. Duty-Cycling Buildings Aggressively: The Next Frontier in HVAC Control

    E-Print Network [OSTI]

    Simunic, Tajana

    network across an entire floor of a university building and our data shows several periods of low energy savings of 7.59% to 12.85% for the HVAC system by controlling just one floor of our four floor- sumers can be lighting, computing infrastructure, or what is most often the case, heating ventilation

  13. Modeling Building Thermal Response to HVAC Virginia Smith, Tamim Sookoor, and Kamin Whitehouse

    E-Print Network [OSTI]

    Whitehouse, Kamin

    temperatures has to be predicted. Making such a prediction is complicated by the fact that weather has a larger the influence of the HVAC system. We present a technique for dynamically estimating the heat load due to weather rooms at a comfortable temperature without wasting any energy conditioning unoccupied rooms. Many homes

  14. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    -Loop Ground-Source Heat Pump Systems. ASHRAE Transactions. 106(1): 380-393. Reprinted by permission from. INTRODUCTION Ground-source heat pump systems have become increas- ingly popular for both residential with conventional systems. In closed-loop ground- source heat pump systems, heat rejection/extraction is accom

  15. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    .D. Smith, J.D. Spitler. 2002. Advances in Ground Source Heat Pump Systems - An International Overview-22, 2002. #12;313 ADVANCES IN GROUND SOURCE HEAT PUMP SYSTEMS AN INTERNATIONAL OVERVIEW James E. Bose, Ph properties, modeling of ground source heat pump systems, development of hybrid systems and further

  16. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    . INTRODUCTION Ground source heat pump systems have become increas- ingly popular for both residential to air source heat pump systems, ground source systems have not been so widely used. This may tools. In ground source heat pump systems, heat is extracted from or rejected to the ground via either

  17. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    source heat pump systems, and design of hybrid ground source systems. This paper describes-coupled heat pump systems is important for design of ground loop heat exchangers, energy analysis of ground in ground-coupled heat pump systems. The short time-step response factors allow for a direct evalu- ation

  18. Two-Nucleon Systems in a Finite Volume

    SciTech Connect (OSTI)

    Briceno, Raul

    2014-11-01

    I present the formalism and methodology for determining the nucleon-nucleon scattering parameters from the finite volume spectra obtained from lattice quantum chromodynamics calculations. Using the recently derived energy quantization conditions and the experimentally determined scattering parameters, the bound state spectra for finite volume systems with overlap with the 3S1-3D3 channel are predicted for a range of volumes. It is shown that the extractions of the infinite-volume deuteron binding energy and the low-energy scattering parameters, including the S-D mixing angle, are possible from Lattice QCD calculations of two-nucleon systems with boosts of |P| <= 2pi sqrt{3}/L in volumes with spatial extents L satisfying fm <~ L <~ 14 fm.

  19. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    properties, modeling of ground source heat pump systems, development of hybrid systems and further.D. Smith, J.D. Spitler. 2002. Advances in Ground Source Heat Pump Systems - An International Overview. Proceedings of the Seventh International Energy Agency Heat Pump Conference. 1:313-324. Beijing. May 19

  20. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    . Underwood. 2003. UK Application of Direct Cooling Ground Source Heat Pump Systems. Proceedings of ASHRAE Tyne, NE18ST, chris.underwood@unn.ac.uk Summary One form of ground-source heat pump (GSHP) system system with condensing gas boilers and vapor compression refrigeration. Introduction Ground source heat

  1. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    .J. Rees, and C. Yavuzturk. 2000. Recent Developments in Ground Source Heat Pump System Design, Modelling A28, p.34. #12;Page 1 of 1 Recent Developments in Ground Source Heat Pump System Design, Modeling research and developments in ground source heat pump system design, modeling, and applications

  2. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (http://www.hvac.okstate.edu).

    E-Print Network [OSTI]

    and Validation of Ground-Source Heat Pump System Models in an Integrated Building and System Simulation and lower maintenance benefits of ground-source heat pump (GSHP) systems, little work has been undertaken Ground Source Heat Pump Laboratory have been used to validate both the heat pump and ground heat

  3. HVAC Equipment Design Options for Near-Zero-Energy Homes (NZEH) -A Stage 2 Scoping Assessment

    SciTech Connect (OSTI)

    Baxter, Van D

    2005-11-01

    Although the energy efficiency of heating, ventilating, and air-conditioning (HVAC) equipment has increased substantially in recent years, new approaches are needed to continue this trend. Conventional unitary equipment and system designs have matured to a point where cost-effective, dramatic efficiency improvements that meet near-zero-energy housing (NZEH) goals require a radical rethinking of opportunities to improve system performance. The large reductions in HVAC energy consumption necessary to support the NZEH goals require a systems-oriented analysis approach that characterizes each element of energy consumption, identifies alternatives, and determines the most cost-effective combination of options. In particular, HVAC equipment must be developed that addresses the range of special needs of NZEH applications in the areas of reduced HVAC and water heating energy use, humidity control, ventilation, uniform comfort, and ease of zoning. This report describes results of a scoping assessment of HVAC system options for NZEH homes. ORNL has completed a preliminary adaptation, for consideration by The U.S. Department of Energy, Energy Efficiency and Renewable Energy Office, Building Technologies (BT) Program, of Cooper's (2001) stage and gate planning process to the HVAC and Water Heating element of BT's multi-year plan, as illustrated in Figure 1. In order to adapt to R&D the Cooper process, which is focused on product development, and to keep the technology development process consistent with an appropriate role for the federal government, the number and content of the stages and gates needed to be modified. The potential federal role in technology development involves 6 stages and 7 gates, but depending on the nature and status of the concept, some or all of the responsibilities can flow to the private sector for product development beginning as early as Gate 3. In the proposed new technology development stage and gate sequence, the Stage 2 'Scoping Assessment' provides the deliverable leading into the Gate 3 'Scoping Assessment Screen'. This report is an example of a Stage 2 deliverable written to document the screening of options against the Gate 3 criteria and to support DOE decision making and option prioritization. The objective of this scoping assessment was to perform a transparent evaluation of the HVAC system options for NZEH based on the applying the Gate 3 criteria uniformly to all options.

  4. R&D Opportunity Assessment: Joining Technologies in HVAC&R -...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    R&D Opportunity Assessment: Joining Technologies in HVAC&R - Workshop on Joining Technologies in HVAC&R R&D Opportunity Assessment: Joining Technologies in HVAC&R - Workshop on...

  5. IEM5303/4323-Manufacturing Systems Design: High Volume Manufacturing Systems

    E-Print Network [OSTI]

    Bukkapatnam, Satish T.S.

    -time quality and asset management in high-volume manufacturing operations elicit student interests to pursue/CAM Technology for High-Volume Manufacturing: Control Hierarchy and Elements Process Planning and NumericalIEM5303/4323-Manufacturing Systems Design: High Volume Manufacturing Systems Schedule: 2-3:30 TR

  6. Higher Efficiency HVAC Motors | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum12,ExecutiveFinancingR Walls - Building America Topa HighHigher Efficiency HVAC

  7. HVAC, Water Heating, and Appliances Overview - 2015 BTO Peer...

    Office of Environmental Management (EM)

    Heating, and Appliances Overview - 2015 BTO Peer Review HVAC, Water Heating, and Appliances Overview - 2015 BTO Peer Review Presenter: Tony Bouza, U.S. Department of Energy View...

  8. Pre-Commercial Demonstration of Cost-Effective Advanced HVAC...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Research Center Optimal control coordination of heating, ventilation, and air conditioning (HVAC) equipment can reduce energy by more than 20% over current building...

  9. Columbia Water & Light- HVAC and Lighting Efficiency Rebates

    Broader source: Energy.gov [DOE]

    Columbia Water & Light (CWL) offers rebates to its commercial and industrial customers for the purchase of high efficiency HVAC installations and efficient lighting. Incentives for certain...

  10. Building America Top Innovations 2014 Profile: HVAC Cabinet Air...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building Science Solutions Optimized Comfort Solutions HVAC Cabinet Air Leakage Test Method (top left) Building America teams evaluated several testing methods to identify...

  11. HVAC component data modeling using industry foundation classes

    E-Print Network [OSTI]

    Bazjanac, Vladimir; Forester, James; Haves, Philip; Sucic, Darko; Xu, Peng

    2002-01-01

    of HVAC components, such as boilers and actuators, with allTable 1. actuator air handler boiler chiller coil controllerattribute lists for the boiler and actuator components. A

  12. Inverted Attic Bulkhead for HVAC Ductwork, Roseville, California...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    for HVAC Ductwork Roseville, California PROJECT INFORMATION Project Name: Long-Term Monitoring of Occupied Test House Location: Roseville, CA Partners: K. Hovnanian Homes,...

  13. Thermoelectric HVAC and Thermal Comfort Enablers for Light-Duty...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and Thermal Comfort Enablers for Light-Duty Vehicle Applications Thermoelectric HVAC and Thermal Comfort Enablers for Light-Duty Vehicle Applications 2012 DOE Hydrogen and Fuel...

  14. PV modules, with a life measured in decades, will typically be in place longer than the outdoor unit of a HVAC system.

    E-Print Network [OSTI]

    Johnson, Eric E.

    PV modules, with a life measured in decades, will typically be in place longer than the outdoor and repaired promptly. PV systems suffer gradual degradation that is often not monitored, and the PV array may with copper conductors. On the other hand, PV systems have numerous modules (tens to thousands) and mounting

  15. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (http://www.hvac.okstate.edu).

    E-Print Network [OSTI]

    .D., J.D. Spitler, and S.J. Rees. 2006. Performance Analysis of Standing Column Well Ground Heat. A comparative life-cycle cost analysis is conducted considering 20 year system operation. INTRODUCTION Ground-source heat pump (GSHP) systems have been gaining increasing popularity in commercial and residential

  16. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    . Ramamoorthy 2000. Bridge Deck Deicing using Geothermal Heat Pumps. Proceedings of the Fourth International using Geothermal Heat Pumps JEFFREY D. SPITLER, PH.D., P.E., MAHADEVAN RAMAMOORTHY Oklahoma State. A system with 16 heat pumps of nominal 30-ton capacity and 250 boreholes, each 76 m deep, was selected

  17. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    and June 1996 on next-generation building energy simulation tools. We first describe the methods usedThis paper has been downloaded from the Building and Environmental Thermal Systems Research Group-Generation in Building Energy Simulation -- A Glimpse of the Future. Proceedings of Building Simulation '97, Vol. 3, pp

  18. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    This paper has been downloaded from the Building and Environmental Thermal Systems Research Group is modular in structure, and uses the heat balance technique to simulate building thermal loads. The Energy been made in the development of airflow models that can simulate interzone airflows and pollution

  19. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    University Stillwater, OK, U.S.A. KEY WORDS Ground source heat pump systems, ground loop heat exchangers. GLHEPRO -- A Design Tool For Commercial Building Ground Loop Heat Exchangers. Proceedings of the Fourth International Heat Pumps in Cold Climates Conference, Aylmer, Québec. August 17-18, 2000. #12;GLHEPRO ­ A DESIGN

  20. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    ., V. Ghatti, D.E. Fisher, and D.G. Scheatzle. 2003. "Experimental Validation of the EnergyPlus Low systems. With the recent release of EnergyPlus (Crawley et al. 2000), designers now have the opportunity ASHRAE Vinay Ghatti Student MemberASHRAE The EnergyPlus low-temperature radiant model was experimentally

  1. Study on Control Performance of HVAC System or Interior Zone and Perimeter Zone in Office Building; Estimation of Optimal PI Tuning in Cooling Operation 

    E-Print Network [OSTI]

    Maehara, K.; Sagara, N.

    2007-01-01

    of not being able to satisfy the requirements of room temperature control during the cooling period in summer, an optimal PID parameter (O-PI) is selected through simulation of its two feedback control systems with mutual influence using the models identified...

  2. Modeling the Earth System, volume 3

    SciTech Connect (OSTI)

    Ojima, D.

    1992-01-01

    The topics covered fall under the following headings: critical gaps in the Earth system conceptual framework; development needs for simplified models; and validating Earth system models and their subcomponents.

  3. Occupancy Based Demand Response HVAC Control Strategy Varick L. Erickson

    E-Print Network [OSTI]

    Cerpa, Alberto E.

    Occupancy Based Demand Response HVAC Control Strategy Varick L. Erickson University of California an efficient demand response HVAC control strategy, actual room usage must be considered. Temperature and CO2 are used for simulations but not for predictive demand response strategies. In this paper, we develop

  4. High-performance commercial building systems

    E-Print Network [OSTI]

    Selkowitz, Stephen

    2003-01-01

    heat pump-based HVAC system (HPAC) and a continuously ventilating, and potentially more energy efficient Advanced Hybrid

  5. M. Bahrami ENSC 461 (S 11) Gas Vapor Mixtures and HVAC 1 Gas Vapor Mixtures and HVAC

    E-Print Network [OSTI]

    Bahrami, Majid

    to the vapor pressure: Tdp = Tsat@ Pv Sling Psychrometer: a rotating set of thermometers one of which measuresM. Bahrami ENSC 461 (S 11) Gas Vapor Mixtures and HVAC 1 Gas Vapor Mixtures and HVAC Atmospheric air normally contains some water vapor (moisture). The dry-air contains no water. Although the amount

  6. Better Buildings Neighborhood Program Business Models Guide: HVAC Contractor Business Model Introduction

    Broader source: Energy.gov [DOE]

    Better Buildings Neighborhood Program Business Models Guide: HVAC Contractor Business Model Introduction.

  7. Measuring Advances in HVAC Distribution System Design

    E-Print Network [OSTI]

    Franconi, E.

    2011-01-01

    lIIvall RH avail Thermal Energy Thermal Avail Input energythermal based index EDE and thermal energy end-use indices.Thus mechanical and thermal energy sources can be combined

  8. Measuring Advances in HVAC Distribution System Design

    E-Print Network [OSTI]

    Franconi, E.

    2011-01-01

    Energy Efficiency and Renewable Energy, Office of BuildingEnergy Efficiency and Renewable Energy, Office of Building

  9. SIMULATION OF RESIDENTIAL HVAC SYSTEM PERFORMANCE

    E-Print Network [OSTI]

    ., and Degenetais, G. Environmental Energy Technologies Division Energy Performance of Buildings Group Lawrence Institute for Energy Efficiency (CIEE) through the U.S. Department of Energy. The research reported here was funded by the California Institute for Energy Efficiency (CIEE), a research unit of the University

  10. Measuring Advances in HVAC Distribution System Design

    E-Print Network [OSTI]

    Franconi, E.

    2011-01-01

    with the inlet flow stream and energy transfers. Thewhen the input energy/fuel streams are a different "quality"

  11. Measuring Advances in HVAC Distribution System Design

    E-Print Network [OSTI]

    Franconi, E.

    2011-01-01

    that provide a useful measure of energy utilization inresults from energy being a poor indicator of useful workuseful can be destroyed - the quality of the energy in the

  12. MAPPING HVAC SYSTEMS FOR SIMULATION IN ENERGYPLUS

    E-Print Network [OSTI]

    Basarkar, Mangesh

    2013-01-01

    Semi-Automated Building Energy Performance Simulation, in:Simulation of Energy Performance, in: Building Simulation

  13. MAPPING HVAC SYSTEMS FOR SIMULATION IN ENERGYPLUS

    E-Print Network [OSTI]

    Basarkar, Mangesh

    2013-01-01

    of a user interface for the EnergyPlus whole building energyAutomated Simulation with EnergyPlus, in: CIB W078-W102:Antipolis, France. EnergyPlus, 2012. EnergyPlus Energy

  14. Designing Forced-Air HVAC Systems

    SciTech Connect (OSTI)

    2010-08-31

    This guide explains proper calculation of heating and cooling design loads for homes.used to calculated for the home using the protocols set forth in the latest edition of the Air Conditioning Contractors of America’s (ACCA) Manual J (currently the 8th edition), ASHRAE 2009 Handbook of Fundamentals, or an equivalent computation procedure.

  15. Wireless Demand Response Controls for HVAC Systems

    E-Print Network [OSTI]

    Federspiel, Clifford

    2010-01-01

    Linksys WRT54G3G-ST Wireless G router for mobile broadband.This router includes a 4-port switch, a wireless G accessrouters for connecting to the DRAS, and tested the wireless

  16. MAPPING HVAC SYSTEMS FOR SIMULATION IN ENERGYPLUS

    E-Print Network [OSTI]

    Basarkar, Mangesh

    2013-01-01

    apps1.eere.energy.gov/buildings/energyplus/. Modelica, 2012.Modelica andthe Modelica Association — Modelica Association [WWW

  17. Advanced HVAC Systems | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i n c i p a l De p u t y A sCOLONY PROJECTRecord For Irradiation -- Indian

  18. Improved Air Volume Control Logic for VAV Systems 

    E-Print Network [OSTI]

    Wei, G.; Claridge, D. E.; Sakuri, Y.; M. Liu

    2000-01-01

    In a VAV (variable air volume) system, the set point of the static pressure (usually measured at 213 downstream of the main supply air duct) is maintained by modulating the fan speed or inlet guide vane position. The set point of the static pressure...

  19. Comparisons of HVAC Simulations between EnergyPlus and DOE-2.2 for Data Centers

    SciTech Connect (OSTI)

    Hong, Tianzhen; Sartor, Dale; Mathew, Paul; Yazdanian, Mehry

    2008-08-13

    This paper compares HVAC simulations between EnergyPlus and DOE-2.2 for data centers. The HVAC systems studied in the paper are packaged direct expansion air-cooled single zone systems with and without air economizer. Four climate zones are chosen for the study - San Francisco, Miami, Chicago, and Phoenix. EnergyPlus version 2.1 and DOE-2.2 version 45 are used in the annual energy simulations. The annual cooling electric consumption calculated by EnergyPlus and DOE-2.2 are reasonablely matched within a range of -0.4percent to 8.6percent. The paper also discusses sources of differences beween EnergyPlus and DOE-2.2 runs including cooling coil algorithm, performance curves, and important energy model inputs.

  20. The Dwyer Series 640 air velocity transmitter is ideal for a wide range of HVAC measurement and control applications, particularly

    E-Print Network [OSTI]

    Berns, Hans-Gerd

    measurements, supply and exhaust fan tracking, industrial hygiene and clean-room systems, air pollution studiesThe Dwyer Series 640 air velocity transmitter is ideal for a wide range of HVAC measurement for use in reasonably clean and dry air streams, appli- cations include multi-point air velocity

  1. Strategy Guideline: Transitioning HVAC Companies to Whole House Performance Contractors

    SciTech Connect (OSTI)

    Burdick, A.

    2012-05-01

    This report describes the findings from research IBACOS conducted related to heating, ventilation, and air conditioning (HVAC) companies who have made the decision to transition to whole house performance contracting (WHPC).

  2. Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics 

    E-Print Network [OSTI]

    Graham, E. L.

    1980-01-01

    Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate...

  3. Strategy Guideline. Transitioning HVAC Companies to Whole House Performance Contractors

    SciTech Connect (OSTI)

    Burdick, Arlan

    2012-05-01

    This report describes the findings from research IBACOS conducted related to heating, ventilation, and air conditioning (HVAC) companies who have made the decision to transition to whole house performance contracting (WHPC).

  4. Deposition of biological aerosols on HVAC heat exchangers

    E-Print Network [OSTI]

    Siegel, Jeffrey; Walker, Iain

    2001-01-01

    ASHRAE IAQ ’88, pp. 10-24. Muyshondt, A. , D. Nutter, and M.contamination on HVAC coils. Muyshondt et al. (1998) discussdynamic simulations of Muyshondt et al. (1998). The current

  5. System 80+{trademark} Standard Design: CESSAR design certification. Volume 13

    SciTech Connect (OSTI)

    1997-12-31

    This report has been prepared in support of the industry effort to standardize nuclear plant designs. This document describes the Combustion Engineering, Inc. System 80+{trademark} Standard Design. This volume contains sections 2 thru 7 of Chapter 15 -- Accident Analyses. Topics covered are: decrease in heat removal by the secondary system; decrease in reactor coolant flow rate; reactivity and power distribution anomalies; increase in RCS inventory; decrease in RCS inventory; and radioactive material release from a system or component. Appendices 15A, 15B, and 15C are included.

  6. CoolCab Test and Evaluation and CoolCalc HVAC Tool Development...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Test and Evaluation and CoolCalc HVAC Tool Development CoolCab Test and Evaluation and CoolCalc HVAC Tool Development 2012 DOE Hydrogen and Fuel Cells Program and Vehicle...

  7. CoolCab Test and Evaluation and CoolCalc HVAC Tool Development...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Evaluation and CoolCalc HVAC Tool Development CoolCab Test and Evaluation and CoolCalc HVAC Tool Development 2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies...

  8. Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions...

    Energy Savers [EERE]

    4: What are the Best Off-the-Shelf HVAC Solutions for Low-Load, High-Performance Homes and Apartments? Critical Question 4: What are the Best Off-the-Shelf HVAC Solutions for...

  9. Issue #7: What are the Best HVAC Solutions for Low-Load, High...

    Energy Savers [EERE]

    7: What are the Best HVAC Solutions for Low-Load, High Performance Homes? Issue 7: What are the Best HVAC Solutions for Low-Load, High Performance Homes? What components and...

  10. CoolCab Thermal Load Reduction Project: CoolCalc HVAC Tool Development...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Thermal Load Reduction Project: CoolCalc HVAC Tool Development CoolCab Thermal Load Reduction Project: CoolCalc HVAC Tool Development 2010 DOE Vehicle Technologies and Hydrogen...

  11. Building America Whole-House Solutions for New Homes: HVAC Design...

    Energy Savers [EERE]

    HVAC Design Strategy for a Hot-Humid Production Builder Building America Whole-House Solutions for New Homes: HVAC Design Strategy for a Hot-Humid Production Builder In this...

  12. Guidelines for the verification and validation of expert system software and conventional software: Bibliography. Volume 8

    SciTech Connect (OSTI)

    Miller, L.A.; Hayes, J.E.; Mirsky, S.M.

    1995-03-01

    This volume contains all of the technical references found in Volumes 1-7 concerning the development of guidelines for the verification and validation of expert systems, knowledge-based systems, other AI systems, object-oriented systems, and conventional systems.

  13. Deposition of biological aerosols on HVAC heat exchangers

    SciTech Connect (OSTI)

    Siegel, Jeffrey; Walker, Ian

    2001-09-01

    Many biologically active materials are transported as bioaerosols 1-10 {micro}m in diameter. These particles can deposit on cooling and heating coils and lead to serious indoor air quality problems. This paper investigates several of the mechanisms that lead to aerosol deposition on fin and tube heat exchangers. A model has been developed that incorporates the effects of several deposition mechanisms, including impaction, Brownian and turbulent diffusion, turbophoresis, thermophoresis, diffusiophoresis, and gravitational settling. The model is applied to a typical range of air velocities that are found in commercial and residential HVAC systems 1 - 6 m/s (200 - 1200 ft/min), particle diameters from 1 - 8 {micro}m, and fin spacings from 3.2 - 7.9 fins/cm (8 - 16 fins/inch or FPI). The results from the model are compared to results from an experimental apparatus that directly measures deposition on a 4.7 fins/cm (12 FPI) coil. The model agrees reasonably well with this measured data and suggests that cooling coils are an important sink for biological aerosols and consequently a potential source of indoor air quality problems.

  14. High Performance HVAC Systems, Part II: Low-Load HVAC Systems for Single and Multifamily Applications

    Broader source: Energy.gov [DOE]

    The Building America Program hosted this no-cost webinar that will discuss the current research on comfort in residential buildings. Results will be presented from 37 new homes that were monitored...

  15. The System 80+ Standard Plant design control document. Volume 17

    SciTech Connect (OSTI)

    1997-12-31

    This Design Control Document (DCD) is a repository of information comprising the System 80+{trademark} Standard Plant Design. The DCD also provides that design-related information to be incorporated by reference in the design certification rule for the System 80+ Standard Plant Design. Applicants for a combined license pursuant to 10 CFR 52 must ensure that the final Design Certification Rule and the associated Statements of Consideration are used when making all licensing decisions relevant to the System 80+ Standard Plant Design. The Design Control Document contains the DCD introduction, The Certified Design Material (CDM) [i.e., ``Tier 1``] and the Approved Design Material (ADM) [i.e., ``Tier 2``] for the System 80+ Standard Plant Design. The CDM includes the following sections: (1) Introductory material; (2) Certified Design Material for System 80+ systems and structures; (3) Certified Design Material for non-system-based aspects of the System 80+ Certified design; (4) Interface requirements; and (5) Site parameters. The ADM, to the extent applicable for the System 80+ Standard Plant Design, includes: (1) the information required for the final safety analysis report under 20 CFR 50.34; (2) other relevant information required by 10 CFR 52.47; and (3) emergency operations guidelines. This volume contains parts 2-7 and appendix 15A for section 15 (Accident Analysis) of the ADM Design and Analysis. Topics covered in these parts are: decrease in heat removal; decrease in RCS flow rate; power distribution anomalies; increase in RCS inventory; decrease in RCS inventory; release of radioactive materials. The appendix covers radiological release models. Also contained here are five technical specifications for section 16 (Technical Specifications) of the ADM Design and Analysis. They are: TS 1.0 Use and Applications; TS 2.0 Safety Limits; TS 3.0 LCO Availability; TS 3.1 Reactivity Control; and TS 3.2 Power Distribution.

  16. Columbia River System Operation Review : Final Environmental Impact Statement, Appendix T (Second Continued Volume): Comments & Responses.

    SciTech Connect (OSTI)

    Columbia River System Operation Review (U.S.)

    1995-11-01

    This is Appendix T (second continued volume) giving public comments and responses to the final environmental impact statement for the Columbia River System.

  17. VOLUME 18, NUMBER 2, 2010 n LINCOLN LABORATORY JOURNAL 47 Wind-Shear System

    E-Print Network [OSTI]

    Cho, John Y. N.

    VOLUME 18, NUMBER 2, 2010 n LINCOLN LABORATORY JOURNAL 47 Wind-Shear System Cost-Benefit Analysis. » #12;48 LINCOLN LABORATORY JOURNAL n VOLUME 18, NUMBER 2, 2010 WIND-SHEAR SYSTEM COST-BENEFIT ANALYSIS-shear system cost benefits in order to retrospectively evaluate the expected safety benefits of wind

  18. Handover Performance of HVAC Duct Based Indoor Wireless Networks

    E-Print Network [OSTI]

    Stancil, Daniel D.

    in indoor wireless net- works (IWN) that use heating, ventilation, and air conditioning (HVAC) ducts point to serve one floor and its staircase region achieves the best handover performance for IWN]. An alternative approach to transmitt/receive the RF signal is to use heating, ventilation, and airconditioning

  19. HVAC Design Strategy for a Hot-Humid Production Builder, Houston, Texas (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-03-01

    BSC worked directly with the David Weekley Homes - Houston division to redesign three floor plans in order to locate the HVAC system in conditioned space. The purpose of this project is to develop a cost effective design for moving the HVAC system into conditioned space. In addition, BSC conducted energy analysis to calculate the most economical strategy for increasing the energy performance of future production houses. This is in preparation for the upcoming code changes in 2015. The builder wishes to develop an upgrade package that will allow for a seamless transition to the new code mandate. The following research questions were addressed by this research project: 1. What is the most cost effective, best performing and most easily replicable method of locating ducts inside conditioned space for a hot-humid production home builder that constructs one and two story single family detached residences? 2. What is a cost effective and practical method of achieving 50% source energy savings vs. the 2006 International Energy Conservation Code for a hot-humid production builder? 3. How accurate are the pre-construction whole house cost estimates compared to confirmed post construction actual cost? BSC and the builder developed a duct design strategy that employs a system of dropped ceilings and attic coffers for moving the ductwork from the vented attic to conditioned space. The furnace has been moved to either a mechanical closet in the conditioned living space or a coffered space in the attic.

  20. System 80+{trademark} Standard Design: CESSAR design certification. Volume 10: Amendment I

    SciTech Connect (OSTI)

    Not Available

    1990-12-21

    This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80{sup +}{trademark} Standard Design. This volume 10 discusses the Steam and Power Conversion System and Radioactive Waste Management.

  1. System 80+{trademark} Standard Design: CESSAR design certification. Volume 9: Amendment I

    SciTech Connect (OSTI)

    Not Available

    1990-12-21

    This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80{sup +}{trademark} Standard Design. This volume 9 discusses Electric Power and Auxiliary Systems.

  2. State energy price system. Volume I: overview and technical documentation

    SciTech Connect (OSTI)

    Fang, J.M.; Nieves, L.A.; Sherman, K.L.; Hood, L.J.

    1982-06-01

    This study utilizes existing data sources and previous analyses of state-level energy prices to develop consistent state-level energy prices series by fuel type and by end-use sector. The fuels are electricity, natural gas, coal, distillate fuel oil, motor gasoline, diesel, kerosene, jet fuel, residual fuel, and liquefied petroleum gas. The end-use sectors are residential, commercial, industrial, transportation, and electric utility. Based upon an evaluation of existing data sources, recommendations were formulated on the feasible approaches for developing a consistent state energy price series. The data series were compiled based upon the approaches approved after a formal EIA review. Detailed documentation was provided, including annual updating procedures. Recommendations were formulated for future improvements in the collection of data or in data processing. Generally, the geographical coverage includes the 50 states and the District of Columbia. Information on state-level energy use was generally taken from the State Energy Data System (SEDS). Corresponding average US prices are also developed using volumes reported in SEDS. To the extent possible, the prices developed are quantity weighted average retail prices. Both a Btu price series and a physical unit price series are developed for each fuel. The period covered by the data series is 1970 through 1980 for most fuels, though prices for electricity and natural gas extend back to 1960. (PSB)

  3. Research on Fuzzy Regulation Strategies in the Constant Air Volume Air Conditioning System 

    E-Print Network [OSTI]

    Bai, T.; Zhang, J.; Ning, N.; Tong, K.; Wu, Y.; Wang, H.

    2006-01-01

    The energy consumption of the constant air volume (CAV) system largely depends on the regulation strategies. Although some air conditioning systems are equipped with automatic regulation devices, others lack effective regulation strategies. To avoid...

  4. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking WithTelecentric viewing system forPortal.1 - MarchVISTAS E x p8,

  5. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking WithTelecentric viewing system forPortal.1 - MarchVISTAS E x

  6. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking WithTelecentric viewing system forPortal.1 - MarchVISTAS E x0,

  7. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking WithTelecentric viewing system forPortal.1 - MarchVISTAS E x0,9,

  8. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking WithTelecentric viewing system forPortal.1 - MarchVISTAS E x0,9,3

  9. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking WithTelecentric viewing system forPortal.1 - MarchVISTAS E x0,9,36

  10. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking WithTelecentric viewing system forPortal.1 - MarchVISTAS E

  11. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking WithTelecentric viewing system forPortal.1 - MarchVISTAS E8,

  12. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking WithTelecentric viewing system forPortal.1 - MarchVISTAS

  13. VOLUME

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effectWorking WithTelecentric viewing system forPortal.1 - MarchVISTAS18 P H Y S

  14. Recent Developments of the Modelica"Buildings" Library for Building Energy and Control Systems

    SciTech Connect (OSTI)

    Wetter, Michael; Zuo, Wangda; Nouidui, Thierry Stephane

    2011-04-01

    At the Modelica 2009 conference, we introduced the Buildings library, a freely available Modelica library for building energy and control systems. This paper reports the updates of the library and presents example applications for a range of heating, ventilation and air conditioning (HVAC) systems. Over the past two years, the library has been further developed. The number of HVAC components models has been doubled and various components have been revised to increase numerical robustness.The paper starts with an overview of the library architecture and a description of the main packages. To demonstrate the features of the Buildings library, applications that include multizone airflow simulation as well as supervisory and local loop control of a variable air volume (VAV) system are briefly described. The paper closes with a discussion of the current development.

  15. DOE Zero Energy Ready Home Low Load High Efficiency HVAC Webinar (Text Version)

    Broader source: Energy.gov [DOE]

    Below is the text version of the DOE Zero Energy Ready Home webinar, Low Load High Efficiency HVAC, presented in May 2014.

  16. R&D Opportunity Assessment: Joining Technologies in HVAC&R -...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    HVAC&R More Documents & Publications Research & Development Roadmap: Next-Generation Low Global Warming Potential Refrigerants Advanced Rotating Heat Exchangers Working Fluids Low...

  17. Optimizing Your Motor-Driven System

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and air conditioning (HVAC) systems in many buildings use single or three-phase electrical power controlled by timers and thermostats to drive motors. These motors supply...

  18. Energy Management Systems: Maximizing Energy Savings

    Broader source: Energy.gov [DOE]

    This webinar covered how to optimize installations of new energy management systems, review EMS strategies following lighting/HVAC retrofit projects, and utilize excess EECBG funding.

  19. System 80+{trademark} Standard Design: CESSAR design certification. Volume 6: Amendment I

    SciTech Connect (OSTI)

    Not Available

    1990-12-21

    This report, entitled Combustion Engineering Standard Safety Analysis Report - Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These documents describe the Combustion Engineering, Inc. System 80+{sup TM} Standard Design. This report, Volume 6, in conjunction with Volume 7, provides a description of engineered safety features.

  20. System 80+{trademark} Standard Design: CESSAR design certification. Volume 8: Amendment I

    SciTech Connect (OSTI)

    Not Available

    1990-12-21

    This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80{sup +}{trademark} Standard Design. This volume 8 provides a description of instrumentation and controls.

  1. System 80+{trademark} Standard Design: CESSAR design certification. Volume 18: Amendment I

    SciTech Connect (OSTI)

    Not Available

    1990-12-21

    This report, entitled Combustion Engineering Standard Safety Analysis Report -- Design Certification (CESSAR-DC), has been prepared in support of the industry effort to standardize nuclear plant designs. These volumes describe the Combustion Engineering, Inc. System 80+{trademark} Standard Design. This Volume 18 provides Appendix B, Probabilistic Risk Assessment.

  2. System-Level Monitoring and Diagnosis of Building HVAC System

    E-Print Network [OSTI]

    Wu, Siyu

    2013-01-01

    Housing, energy and thermal comfort: A review of 10D. Liao, Evaluation on energy and thermal perfor- mance forsystematic evaluation on energy and thermal performance for

  3. A systems approach to retrofitting residential HVAC systems

    E-Print Network [OSTI]

    McWilliams, J.A.; Walker, I.S.

    2004-01-01

    LBNL’s Home Energy Saver (http://homeenergysaver.lbl.gov/),to DOE’s Home Energy Saver (homenergysaver.lbl.gov) and the

  4. System-Level Monitoring and Diagnosis of Building HVAC System

    E-Print Network [OSTI]

    Wu, Siyu

    2013-01-01

    695. [50] M. Wetter, Modelica-based modelling and simulationhave been working on Modelica and EnergyPlus simulation59], DOE-2, TRANSYS, Modelica [50], etc. make use of the

  5. A Metadata Generation System for Scanned Scientic Volumes

    E-Print Network [OSTI]

    Giles, C. Lee

    functionalities to digital library users. We propose methods for automatically generating volume level, issue are underway at public and commercial digital libraries to preserve cultural artifacts in digital format in the public domain, the Universal Library Project (also called the Million Book Project) [8] has completed

  6. A Metadata Generation System for Scanned Scientific Volumes

    E-Print Network [OSTI]

    Giles, C. Lee

    functionalities to digital library users. We propose methods for automatically generating volume level, issue are underway at public and commercial digital libraries to preserve cultural artifacts in digital format in the public domain, the Universal Library Project (also called the Million Book Project) [8] has completed

  7. Two-particle multichannel systems in a finite volume with arbitrary spin

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Briceno, Raul A.

    2014-04-08

    The quantization condition for two-particle systems with arbitrary number of two-body open coupled channels, spin and masses in a finite cubic volume with either periodic or twisted boundary conditions is presented. The condition presented is in agreement with all previous studies of two-body systems in a finite volume. The result is relativistic, holds for all momenta below the three- and four-particle thresholds, and is exact up to exponential volume corrections that are governed by L/r, where L is the spatial extent of the volume and r is the range of the interactions between the particles. With hadronic systems the rangemore »of the interaction is set by the inverse of the pion mass, m?, and as a result the formalism presented is suitable for m?L>>1. Implications of the formalism for the studies of multichannel baryon-baryon systems are discussed.« less

  8. Page 1 of 4 Fig. 1. Wireless system for bladder volume monitoring. The belt is

    E-Print Network [OSTI]

    Chiao, Jung-Chih

    Page 1 of 4 Fig. 1. Wireless system for bladder volume monitoring. The belt is worn at the waist of the patient. In this conceptual drawing, the belt is moved upward in order to show the implant location

  9. Impact of the Variable Refrigerant Volume Air Conditioning System on Building Energy Efficiency 

    E-Print Network [OSTI]

    Zhu, H.

    2006-01-01

    The application of the variable refrigerant volume multi-zone air conditioning systems has met with mixed results since the publication of the Design Standard for Energy Efficiency of Public Buildings. This paper analyzes the characteristics...

  10. Evaluation of spatial-spectral filtering in non-paraxial volume holographic imaging systems

    E-Print Network [OSTI]

    Watson, Jonathan M

    2008-01-01

    In this thesis, the properties of transmission-mode volume phase holograms as spatial-spectral filters in optical systems for microscopic medical imaging are evaluated. In experiment, the relationship between the angle of ...

  11. System and method for radiation dose calculation within sub-volumes of a monte carlo based particle transport grid

    DOE Patents [OSTI]

    Bergstrom, Paul M. (Livermore, CA); Daly, Thomas P. (Livermore, CA); Moses, Edward I. (Livermore, CA); Patterson, Jr., Ralph W. (Livermore, CA); Schach von Wittenau, Alexis E. (Livermore, CA); Garrett, Dewey N. (Livermore, CA); House, Ronald K. (Tracy, CA); Hartmann-Siantar, Christine L. (Livermore, CA); Cox, Lawrence J. (Los Alamos, NM); Fujino, Donald H. (San Leandro, CA)

    2000-01-01

    A system and method is disclosed for radiation dose calculation within sub-volumes of a particle transport grid. In a first step of the method voxel volumes enclosing a first portion of the target mass are received. A second step in the method defines dosel volumes which enclose a second portion of the target mass and overlap the first portion. A third step in the method calculates common volumes between the dosel volumes and the voxel volumes. A fourth step in the method identifies locations in the target mass of energy deposits. And, a fifth step in the method calculates radiation doses received by the target mass within the dosel volumes. A common volume calculation module inputs voxel volumes enclosing a first portion of the target mass, inputs voxel mass densities corresponding to a density of the target mass within each of the voxel volumes, defines dosel volumes which enclose a second portion of the target mass and overlap the first portion, and calculates common volumes between the dosel volumes and the voxel volumes. A dosel mass module, multiplies the common volumes by corresponding voxel mass densities to obtain incremental dosel masses, and adds the incremental dosel masses corresponding to the dosel volumes to obtain dosel masses. A radiation transport module identifies locations in the target mass of energy deposits. And, a dose calculation module, coupled to the common volume calculation module and the radiation transport module, for calculating radiation doses received by the target mass within the dosel volumes.

  12. UGA DESIGN & CONSTRUCTION SUPPLEMENTAL GENERAL REQUIREMENTS & STANDARDS GENERAL MECHANICAL REQUIREMENTS (HVAC)

    E-Print Network [OSTI]

    Arnold, Jonathan

    UGA DESIGN & CONSTRUCTION SUPPLEMENTAL GENERAL REQUIREMENTS & STANDARDS GENERAL MECHANICAL REQUIREMENTS (HVAC) JANUARY 16, 2015 23 00 001 23 00 00 GENERAL MECHANICAL REQUIREMENTS (HVAC) 1. GENERAL A. Related sections: i. 00 00 07 ­ Design Professional Design Process Requirements ii. 00 00

  13. A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2

    E-Print Network [OSTI]

    A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2 3 4 Peng Xu, Philip Haves a library of equipment reference models developed for automated fault detection and diagnosis of secondary of automatic documentation methods in the library. INTRODUCTION The increasing complexity of building HVAC

  14. IBM and Energy Efficiency: Systems Recommisiong and Optimization 

    E-Print Network [OSTI]

    Veilleux, Y.; Boulianne, J. P.; Lefebvre, P.

    2013-01-01

    and revision of calibration process; and Tuning of PID control loops. IBM Bromont Manufacturing Plant IBM and Energy Efficiency - Recommissioning: Improving Buildings Systems Efficiency ? 2013 IBM Corporation8 Boilers: Steam pressure optimization Before.... The recommissioning and optimization program for the HVAC systems was established and based on the following activities: IBM Bromont Recommissioning Program: HVAC HVAC Systems Optimization Key Activities IBM Bromont Manufacturing Plant IBM and Energy Efficiency...

  15. Strategy Guideline: Compact Air Distribution Systems

    SciTech Connect (OSTI)

    Burdick, A.

    2013-06-01

    This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  16. HVAC's Variable Refrigerant Flow (VRF) Technology 

    E-Print Network [OSTI]

    Jones, S.

    2012-01-01

    Ducted Units Ceiling Suspended Floor Standing 27 VRF Energy-Efficiency and Environmental Impact Utilizing VRF with LEED ? Energy and Atmosphere: VRF can achieve up to 21 points ? Environmental Quality: VRF can achieve up to seven... points LEED NC 3.0 ? Certified: 40-49 points ? Silver: 50-59 points ? Gold: 60-79 points ? Platinum: 80 + points 29 VRF Systems and Energy Modeling ? Energy usage and cost for the VRF systems can be modeled using EnergyPro EnergyPro uses...

  17. Research & Development Roadmap: Emerging HVAC Technologies | Department of

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on DeliciousMathematicsEnergyInterestedReplacement-2-A Wholesale Power RateEnergySection 1222Energy HVAC

  18. Building America Webinar: High Performance Space Conditioning Systems, Part II

    Broader source: Energy.gov [DOE]

    The webinar on Nov. 18, 2014, continued the series on strategies to improve the performance of HVAC systems for low load homes and home performance retrofits.

  19. Building America Webinar: High Performance Space Conditioning Systems, Part I

    Broader source: Energy.gov [DOE]

    The webinar on Oct. 23, 2014 focused on strategies to improve the performance of HVAC systems for low load homes and home performance retrofits.

  20. High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems

    Broader source: Energy.gov [DOE]

    Project objective: Advance the technology for well fluids lifting systems to meet the foreseeable pressure; temperature; and longevity needs of the Enhanced Geothermal Systems (EGS) industry.

  1. Mechanically Cooled Large-Volume Germanium Detector Systems for Nuclear Explosion Monitoring DOENA27323-1

    SciTech Connect (OSTI)

    Hull, E.L.

    2006-07-28

    Compact maintenance free mechanical cooling systems are being developed to operate large volume germanium detectors for field applications. To accomplish this we are utilizing a newly available generation of Stirling-cycle mechanical coolers to operate the very largest volume germanium detectors with no maintenance. The user will be able to leave these systems unplugged on the shelf until needed. The flip of a switch will bring a system to life in ~ 1 hour for measurements. The maintenance-free operating lifetime of these detector systems will exceed 5 years. These features are necessary for remote long-duration liquid-nitrogen free deployment of large-volume germanium gamma-ray detector systems for Nuclear Explosion Monitoring. The Radionuclide Aerosol Sampler/Analyzer (RASA) will greatly benefit from the availability of such detectors by eliminating the need for liquid nitrogen at RASA sites while still allowing the very largest available germanium detectors to be reliably utilized.

  2. Assessment of effectiveness of geologic isolation systems. CIRMIS data system. Volume 3. Generator routines

    SciTech Connect (OSTI)

    Friedrichs, D.R.; Argo, R.S.

    1980-01-01

    The Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program is developing and applying the methodology for assessing the far-field, long-term post-closure safety of deep geologic nuclear waste repositories. AEGIS is being performed by Pacific Northwest Laboratory (PNL) under contract with the Office of Nuclear Waste Isolation (ONWI) for the Department of Energy (DOE). One task within AEGIS is the development of methodology for analysis of the consequences (water pathway) from loss of repository containment as defined by various release scenarios. The various input parameters required in the analysis are compiled in data systems. The data are organized and prepared by various input subroutines for utilization by the hydraulic and transport codes. The hydrologic models simulate the groundwater flow systems and provide water flow directions, rates, and velocities as inputs to the transport models. Outputs from the transport models are basically graphs of radionuclide concentration in the groundwater plotted against time. After dilution in the receiving surface-water body (e.g., lake, river, bay), these data are the input source terms for the dose models, if dose assessments are required. The dose models calculate radiation dose to individuals and populations. CIRMIS (Comprehensive Information Retrieval and Model Input Sequence) Data System, a storage and retrieval system for model input and output data, including graphical interpretation and display is described. This is the third of four volumes of the description of the CIRMIS Data System.

  3. State energy price system. Volume II: data base development

    SciTech Connect (OSTI)

    Fang, J.M.; Nieves, L.A.; Sherman, K.L.; Hood, L.J.

    1982-06-01

    This volume documents the entire data development process in sufficient detail to permit critical assessment of the data base. However, since a methodological discussion is included in Chapter 3 of Volume I, it is not repeated here. The data base development process was conducted in a fuel-by-fuel fashion, following the general sequence of electricity, natural gas, coal, distillate fuel, motor gasoline, diesel, kerosene, jet fuel, residual fuel, and liquefied petroleum gas. For each of the fuels, a detailed data source review was conducted, which included a preliminary screening against criteria set up for this purpose. After this first screening, the data sources that met most of the review criteria were evaluated in more detail. If one data source met all the criteria, that data source was recommended for use, with minimal change or imputation. If there were substantial gaps in the available data series, then alternative imputation procedures were developed and compared, and recommendations were formulated. This entire procedure was then documented in a draft working paper for review and discussion. To the extent reasonable and practical, comments from the formal EIA reviews were then incorporated into the final recommendations and the data base was developed.

  4. Fouling of HVAC fin and tube heat exchangers

    SciTech Connect (OSTI)

    Siegel, Jeffrey; Carey, Van P.

    2001-07-01

    Fin and tube heat exchangers are used widely in residential, commercial and industrial HVAC applications. Invariably, indoor and outdoor air contaminants foul these heat exchangers. This fouling can cause decreased capacity and efficiency of the HVAC equipment as well as indoor air quality problems related to microbiological growth. This paper describes laboratory studies to investigate the mechanisms that cause fouling. The laboratory experiments involve subjecting a 4.7 fins/cm (12 fins/inch) fin and tube heat exchanger to an air stream that contains monodisperse particles. Air velocities ranging from 1.5-5.2 m/s (295 ft/min-1024 ft/min) and particle sizes from 1--8.6 {micro}m are used. The measured fraction of particles that deposit as well as information about the location of the deposited material indicate that particles greater than about 1 {micro}m contribute to fouling. These experimental results are used to validate a scaling analysis that describes the relative importance of several deposition mechanisms including impaction, Brownian diffusion, turbophoresis, thermophoresis, diffusiophoresis, and gravitational settling. The analysis is extended to apply to different fin spacings and particle sizes typical of those found in indoor air.

  5. Diagnosis of Effectiveness of HVAC System and Energy Performance of Osaka-Gas Building through Retro-Commissioning Part 2 Handling the Data Produced by BEMS and Some Results of Analyses 

    E-Print Network [OSTI]

    Yamaha, M.; Ando,T.

    2014-01-01

    Syst.-Tech Nagoya, Japan 1 ESL-IC-14-09-17a Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 Outlines • Description of the system • Performance indices for co-generation • Data... properties from BEMS • Results • Conclusions 2 ESL-IC-14-09-17a Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 Description of the system 3 R1 R2 Waste heat recovery type absorption...

  6. Joint HVAC transmission EMF environmental study

    SciTech Connect (OSTI)

    Stormshak, F.; Thompson, J. (Oregon State Univ., Corvallis, OR (United States))

    1992-05-01

    This document describes the rationale, procedures, and results of a carefully controlled study conducted to establish whether chronic exposure of female (ewe) Suffolk lambs to the environment of a 500-kV 60-Hz transmission line would affect various characteristics of growth, endocrine function, and reproductive development. This experiment used identical housing and management schemes for control and line-exposed ewes, thus minimizing these factors as contributors to between-group experimental error. Further, throughout the 10-month duration of this study, changes in electric and magnetic fields, audible noise, and weather conditions were monitored continuously by a computerized system. Such measurements provided the opportunity to identify any relationship between environmental factors and biological responses. Because of reports in the literature that electric and magnetic fields alter concentrations of melatonin in laboratory animals, the primary objective of this study was to ascertain whether a similar effect occurs in lambs exposed to a 500-kV a-c line in a natural setting. In addition, onset of puberty, changes in body weight, wool growth, and behavior were monitored. To determine whether the environment of a 500-kV line caused stress in the study animals, serum levels of cortisol were measured. The study was conducted at Bonneville Power Administration's Ostrander Substation near Estacada, Oregon.

  7. TPX: Contractor preliminary design review. Volume 2, PF systems engineering

    SciTech Connect (OSTI)

    Calvin, H.A.

    1995-07-28

    This system development specification covers the Poloidal Field (PF) Magnet System, WBS 14 in the Princeton Plasma Physics Laboratory TPX Program to build a tokamak fusion reactor. This specification establishes the performance, design, development and test requirements of the PF Magnet System.

  8. Evaluation of line focus solar central power systems. Volume II. Systems evaluation

    SciTech Connect (OSTI)

    Not Available

    1980-03-15

    An evaluation was completed to ascertain the applicability of line focus technologies to electrical power applications and to compare their performance and cost potential with point focus central receiver power systems. It was concluded that although the high temperature line focus (SRI) and fixed mirror line focus (GA) concepts duplicate the heat source characteristics and power conversion technology of the central receiver concepts these configurations do not offer a sufficient improvement in cost to warrant full scale development. The systems are, however, less complex than their point focus counterpart and should the central receiver system development falter they provide reasonable technology alternatives. The parabolic trough concept (BDM) was found to provide a low temperature technology alternative to the central receiver concept with promising performance and cost potential. Its continued development is recommended, with special emphasis on lower temperature (< 700/sup 0/F) applications. Finally, a variety of new promising line focus power system configurations were identified for a range of utility and industrial applications and recommendations were made on their implementation. This volume contains the detailed report. (WHK)

  9. Building America Expert Meeting Report: Transitioning Traditional HVAC Contractors to Whole House Performance Contractors

    SciTech Connect (OSTI)

    Burdick, A.

    2011-10-01

    This report outlines findings resulting from a U.S. Department of Energy Building America expert meeting to determine how HVAC companies can transition from a traditional contractor status to a service provider for whole house energy upgrade contracting. IBACOS has embarked upon a research effort under the Building America Program to understand business impacts and change management strategies for HVAC companies. HVAC companies can implement these strategies in order to quickly transition from a 'traditional' heating and cooling contractor to a service provider for whole house energy upgrade contracting. Due to HVAC service contracts, which allow repeat interaction with homeowners, HVAC companies are ideally positioned in the marketplace to resolve homeowner comfort issues through whole house energy upgrades. There are essentially two primary ways to define the routes of transition for an HVAC contractor taking on whole house performance contracting: (1) Sub-contracting out the shell repair/upgrade work; and (2) Integrating the shell repair/upgrade work into their existing business. IBACOS held an Expert Meeting on the topic of Transitioning Traditional HVAC Contractors to Whole House Performance Contractors on March 29, 2011 in San Francisco, CA. The major objectives of the meeting were to: Review and validate the general business models for traditional HVAC companies and whole house energy upgrade companies Review preliminary findings on the differences between the structure of traditional HVAC Companies and whole house energy upgrade companies Seek industry input on how to structure information so it is relevant and useful for traditional HVAC contractors who are transitioning to becoming whole house energy upgrade contractors Seven industry experts identified by IBACOS participated in the session along with one representative from the National Renewable Energy Laboratory (NREL). The objective of the meeting was to validate the general operational profile of an integrated whole house performance contracting company and identify the most significant challenges facing a traditional HVAC contractor looking to transition to a whole house performance contractor. To facilitate the discussion, IBACOS divided the business operations profile of a typical integrated whole house performance contracting company (one that performs both HVAC and shell repair/upgrade work) into seven Operational Areas with more detailed Business Functions and Work Activities falling under each high-level Operational Area. The expert panel was asked to review the operational profile or 'map' of the Business Functions. The specific Work Activities within the Business Functions identified as potential transition barriers were rated by the group relative to the value in IBACOS creating guidance ensuring a successful transition and the relative difficulty in executing.

  10. International Journal of Intelligent Systems Volume 21, Issue 12, 2006

    E-Print Network [OSTI]

    Michalski, Ryszard S.

    Mason University Fairfax, VA, 22030 *Also with the Institute of Computer Science, Polish Academy, specialized for the optimization of evaporators and condensers in cooling systems, respectively. The designs

  11. Renewable Electricity Futures Study Volume 4: Bulk Electric Power Systems: Operations and Transmission Planning

    Office of Energy Efficiency and Renewable Energy (EERE)

    This volume focuses on the role of variable renewable generation in creating challenges to the planning and operations of power systems and the expansion of transmission to deliver electricity from remote resources to load centers. The technical and institutional changes to power systems that respond to these challenges are, in many cases, underway, driven by the economic benefits of adopting more modern communication, information, and computation technologies that offer significant operational cost savings and improved asset utilization. While this volume provides background information and numerous references, the reader is referred to the literature for more complete tutorials.

  12. RELAP5/MOD3 code manual: Code structure, system models, and solution methods. Volume 1

    SciTech Connect (OSTI)

    1995-08-01

    The RELAP5 code has been developed for best estimate transient simulation of light water reactor coolant systems during postulated accidents. The code models the coupled behavior of the reactor coolant system and the core for loss-of-coolant accidents, and operational transients, such as anticipated transient without scram, loss of offsite power, loss of feedwater, and loss of flow. A generic modeling, approach is used that permits simulating a variety of thermal hydraulic systems. Control system and secondary system components are included to permit modeling of plant controls, turbines, condensers, and secondary feedwater systems. RELAP5/MOD3 code documentation is divided into seven volumes: Volume I provides modeling theory and associated numerical schemes.

  13. Economic development through biomass system integration. Volumes 2--4

    SciTech Connect (OSTI)

    DeLong, M.M.

    1995-10-01

    Report documents a feasibility study for an integrated biomass power system, where an energy crop (alfalfa) is the feedstock for a processing plant and a power plant (integrated gasification combined cycle) in a way that benefits the facility owners.

  14. POEM: Power-efficient Occupancy-based Energy Management System

    E-Print Network [OSTI]

    Cerpa, Alberto E.

    is electrical energy [1]. Of this total, 50% of the energy consumed in buildings is used for heating, air-conditioningPOEM: Power-efficient Occupancy-based Energy Management System Varick L. Erickson Elect. Eng for Heating Ventilation and Air-Conditioning (HVAC) systems. Current HVAC systems only condition based

  15. Particle loading rates for HVAC filters, heat exchangers, and ducts Nomenclature

    E-Print Network [OSTI]

    Siegel, Jeffrey

    particle mass emission rate distribution func- tion for resuspension (mg/lm h) Es particle mass emission The results in this paper suggest important factors that lead to particle deposition on HVAC components

  16. What are the Best HVAC Solutions for Low-Load, High Performance Homes?"

    Broader source: Energy.gov [DOE]

    This presentation was given at the Summer 2012 DOE Building America meeting on July 26, 2012, and addressed the question ŤWhat are the best HVAC solutions for low-load, high performance homes?"

  17. Flexibility of Commercial Building HVAC Fan as Ancillary Service for Smart Grid

    E-Print Network [OSTI]

    Maasoumy, Mehdi

    2013-01-01

    controlled loads for ancillary services,” in Proc. PSCC,P. Barooah, and S. Meyn, “Ancillary service for the grid viaBuilding HVAC Fan as Ancillary Service for Smart Grid Mehdi

  18. Building America Expert Meeting Report. Transitioning Traditional HVAC Contractors to Whole House Performance Contractors

    SciTech Connect (OSTI)

    Burdick, Arlan

    2011-10-01

    This expert meeting was hosted by the IBACOS Building America research team to determine how HVAC companies can transition from a traditional contractor status to a service provider for whole house energy upgrade contracting.

  19. Mechanically Cooled Large-Volume Germanium Detector Systems for Neclear Explosion Monitoring DOENA27323-2

    SciTech Connect (OSTI)

    Hull, E.L.

    2006-10-30

    Compact maintenance free mechanical cooling systems are being developed to operate large volume high-resolution gamma-ray detectors for field applications. To accomplish this we are utilizing a newly available generation of Stirling-cycle mechanical coolers to operate the very largest volume germanium detectors with no maintenance. The user will be able to leave these systems unplugged on the shelf until needed. The maintenance-free operating lifetime of these detector systems will exceed 5 years. Three important factors affect the operation of mechanically cooled germanium detectors: temperature, vacuum, and vibration. These factors will be studied in the laboratory at the most fundamental levels to insure a solid understanding of the physical limitations each factor places on a practical mechanically cooled germanium detector system. Using this knowledge, mechanically cooled germanium detector prototype systems will be designed and fabricated.

  20. Progress in passive solar energy systems. Volume 8. Part 1

    SciTech Connect (OSTI)

    Hayes, J.; Andrejko, D.A.

    1983-01-01

    This book presents the papers given at a conference sponsored by the US DOE, the Solar Energy Research Institute, SolarVision, Inc., and the Southern California Solar Energy Society. The topics considered at the conference included sizing solar energy systems for agricultural applications, a farm scale ethanol production plant, the EEC wind energy RandD program, the passive solar performance assessment of an earth-sheltered house, the ARCO 1 MW photovoltaic power plant, the performance of a dendritic web photovoltaic module, second generation point focused concentrators, linear fresnel lens concentrating photovoltaic collectors, photovoltaic conversion efficiency, amorphous silicon thin film solar cells, a photovoltaic system for a shopping center, photovoltaic power generation for the utility industry, spectral solar radiation, and the analysis of insolation data.

  1. Economic development through biomass system integration: Volume 1

    SciTech Connect (OSTI)

    DeLong, M.M.

    1995-10-01

    This report documents a feasibility study for an integrated biomass power system, where an energy crop (alfalfa) is the feedstock for a processing plant and a power plant (integrated gasification combined cycle) in a way that benefits the facility owners. Chapters describe alfalfa basics, production risks, production economics, transportation and storage, processing, products, market analysis, business analysis, environmental impact, and policy issues. 69 figs., 63 tabs.

  2. Volume 50, Number 4 2009 361 Weakly electric fishes have been an important model system

    E-Print Network [OSTI]

    Chacron, Maurice

    Volume 50, Number 4 2009 361 Abstract Weakly electric fishes have been an important model system in behavioral neuroscience for more than 40 years. These fishes use a specialized electric organ to produce fish. Weakly electric fish have been routinely used in tightly con- trolled neurophysiological

  3. Comparison of Building Energy Modeling Programs: HVAC Systems

    E-Print Network [OSTI]

    Zhou, Xin

    2014-01-01

    combustion turbine chiller; electric chiller chiller; Screwturbine chillers, and electric chillers. DeST has screw

  4. Unified HVAC and Refrigeration Control Systems for Small Footprint...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Presentationname Benchmark Volttron on small devices Intel Next Unit of Computing (NUC) Raspberry Pi 2 BeagleBone Black 350 - 400 35 (85 fully loaded) 21...

  5. Using Energy Management Control Systems for HVAC Operational Diagnostics 

    E-Print Network [OSTI]

    Stum, K.

    1998-01-01

    unit (TU). If this is greater than 10% of the maximum box CFM rating, there may be a flow sensor or control loop malfunction. The moving average space temperature deviation is also hacked and can immediately detect when there is a problem...

  6. Fault Detection and Diagnosis in Building HVAC Systems

    E-Print Network [OSTI]

    Najafi, Massieh

    2010-01-01

    of outside air condition, occupant behavior, and buildingair condition and occupant behavior) and fault condition (

  7. Co-simulation of innovative integrated HVAC systems in buildings

    E-Print Network [OSTI]

    Trcka, Marija

    2010-01-01

    ESP-r [http://www.esru.strath.ac.uk], EnergyPlus [http://Morrison 2009], COMIS and EnergyPlus [Huang et al. 1999],McDowell et al. 2003], EnergyPlus and MIT-CFD [Zhai 2003],

  8. Comparison of Building Energy Modeling Programs: HVAC Systems

    E-Print Network [OSTI]

    Zhou, Xin

    2014-01-01

    energy balance on the water and air sides of the air/watercurves and performed on the water and air side of thebalance on the water and outdoor air web-bulb air/water

  9. The Application of Ultraviolet Germicidal Technology in HVAC Systems 

    E-Print Network [OSTI]

    Taylor, M. J.

    2000-01-01

    ) filtration is another alternative. HEPA filters have the ability to intercept many fungal spores. However, they also intercept nutrients, and if damp, provide a site for the spores to grow and multiply. The spores may grow through the filter material..., releasing spores on the downstream side of the filter.12 The result is that the filter contributes to the increase in the number of spores in the occupied space rather than decreases them. HEPA filters are unable to remove viruses. Typical HEPA filters...

  10. Comparison of Control Strategies for Energy Efficient Building HVAC Systems

    E-Print Network [OSTI]

    Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

    2014-01-01

    transfer in rooms in the modelica buildings library. [18] A.Building models are first captured in Modelica [1]to leverage Modelica’s rich building component library and

  11. Co-simulation of innovative integrated HVAC systems in buildings

    E-Print Network [OSTI]

    Trcka, Marija

    2010-01-01

    Wetter, M. , 2009. Modelica-based Modeling and Simulation totools like TRNSYS or Modelica [http://www.modelica.org] have

  12. Multi-Sensor Single-Actuator Control of HVAC Systems 

    E-Print Network [OSTI]

    Lin, C.; Auslander, D.; Federspiel, C.

    2002-01-01

    to replace the single sensor in one room with a network of sensors having at least one sensor per room. This paper addresses this multi-sensor, single-actuator control problem. We used computer simulations and optimization to study the problem. We designed a...

  13. Software for fault detection in HVAC systems in commercial buildings

    E-Print Network [OSTI]

    Deshmukh, Suhrid Avinash

    2014-01-01

    The building sector of the United States currently consumes over 41% of the United States primary energy supply. Estimates suggest that between 5 and 30% of any building's annual energy consumption is unknowingly wasted ...

  14. Energy Efficient HVAC System for Distributed Cooling/Heating with

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum12, 2015 Infographic courtesyEducation Data JamDepartment ofEEREPrecipitator

  15. Integration of HVAC System Design with Simplified Duct Distribution -

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on DeliciousMathematicsEnergy HeadquartersFuelBConservationEnergy5975-01 REPORTDepartmentMethodologyfrom

  16. Unified HVAC and Refrigeration Control Systems for Small Footprint Supermarkets

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on DeliciousMathematics And Statistics » USAJobs Search USAJobs Search The jobs listedNuclear1 1DOE NuclearUnearthing for

  17. enVerid Systems - HVAC Load Reduction | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX E LIST OFAMERICA'S FUTURE.EnergyWooden Rooftops |.doc&#0;8 I N S P

  18. Position feedback system for volume holographic storage media

    DOE Patents [OSTI]

    Hays, Nathan J. (San Francisco, CA); Henson, James A. (Morgan Hill, CA); Carpenter, Christopher M. (Sunnyvale, CA); Akin, Jr.. William R. (Morgan Hill, CA); Ehrlich, Richard M. (Saratoga, CA); Beazley, Lance D. (San Jose, CA)

    1998-07-07

    A method of holographic recording in a photorefractive medium wherein stored holograms may be retrieved with maximum signal-to noise ratio (SNR) is disclosed. A plurality of servo blocks containing position feedback information is recorded in the crystal and made non-erasable by heating the crystal. The servo blocks are recorded at specific increments, either angular or frequency, depending whether wavelength or angular multiplexing is applied, and each servo block is defined by one of five patterns. Data pages are then recorded at positions or wavelengths enabling each data page to be subsequently reconstructed with servo patterns which provide position feedback information. The method of recording data pages and servo blocks is consistent with conventional practices. In addition, the recording system also includes components (e.g. voice coil motor) which respond to position feedback information and adjust the angular position of the reference angle of a reference beam to maximize SNR by reducing crosstalk, thereby improving storage capacity.

  19. Model documentation Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1

    SciTech Connect (OSTI)

    1996-02-26

    The Natural Gas Transmission and Distribution Model (NGTDM) of the National Energy Modeling System is developed and maintained by the Energy Information Administration (EIA), Office of Integrated Analysis and Forecasting. This report documents the archived version of the NGTDM that was used to produce the natural gas forecasts presented in the Annual Energy Outlook 1996, (DOE/EIA-0383(96)). The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic approach, and provides detail on the methodology employed. Previously this report represented Volume I of a two-volume set. Volume II reported on model performance, detailing convergence criteria and properties, results of sensitivity testing, comparison of model outputs with the literature and/or other model results, and major unresolved issues.

  20. Technical specifications manual for the MARK-1 pulsed ionizing radiation detection system. Volume 1

    SciTech Connect (OSTI)

    Lawrence, R.S.; Harker, Y.D.; Jones, J.L.; Hoggan, J.M.

    1993-03-01

    The MARK-1 detection system was developed by the Idaho National Engineering Laboratory for the US Department of Energy Office of Arms Control and Nonproliferation. The completely portable system was designed for the detection and analysis of intense photon emissions from pulsed ionizing radiation sources. This manual presents the technical design specifications for the MARK-1 detection system and was written primarily to assist the support or service technician in the service, calibration, and repair of the system. The manual presents the general detection system theory, the MARK-1 component design specifications, the acquisition and control software, the data processing sequence, and the system calibration procedure. A second manual entitled: Volume 2: Operations Manual for the MARK-1 Pulsed Ionizing Radiation Detection System (USDOE Report WINCO-1108, September 1992) provides a general operational description of the MARK-1 detection system. The Operations Manual was written primarily to assist the field operator in system operations and analysis of the data.

  1. Mechanically Cooled Large-Volume Germanium Detector Systems for Nuclear Explosion Monitoring

    SciTech Connect (OSTI)

    Hull, Ethan L.; Pehl, Richard H.; Lathrop, James R.; Martin, Gregory N.; Mashburn, R. B.; Miley, Harry S.; Aalseth, Craig E.; Hossbach, Todd W.; Bowyer, Ted W.

    2006-09-21

    Compact maintenance free mechanical cooling systems are being developed to operate large volume (~570 cm3, ~3 kg, 140% or larger) germanium detectors for field applications. We are using a new generation of Stirling-cycle mechanical coolers for operating the very largest volume germanium detectors with absolutely no maintenance or liquid nitrogen requirements. The user will be able to leave these systems unplugged on the shelf until needed. The flip of a switch will bring a system to life in ~1 hour for measurements. The maintenance-free operating lifetime of these detector systems will exceed five years. These features are necessary for remote long-duration liquid-nitrogen free deployment of large-volume germanium gamma-ray detector systems for Nuclear Explosion Monitoring (NEM). The Radionuclide Aerosol Sampler/Analyzer (RASA) will greatly benefit from the availability of such detectors by eliminating the need for liquid nitrogen at RASA sites while still allowing the very largest available germanium detectors to be utilized. These mechanically cooled germanium detector systems being developed here will provide the largest, most sensitive detectors possible for use with the RASA. To provide such systems, the appropriate technical fundamentals are being researched. Mechanical cooling of germanium detectors has historically been a difficult endeavor. The success or failure of mechanically cooled germanium detectors stems from three main technical issues: temperature, vacuum, and vibration. These factors affect one another. There is a particularly crucial relationship between vacuum and temperature. These factors will be experimentally studied both separately and together to insure a solid understanding of the physical limitations each factor places on a practical mechanically cooled germanium detector system for field use. Using this knowledge, a series of mechanically cooled germanium detector prototype systems are being designed and fabricated. Our collaborators at Pacific Northwest National Laboratory (PNNL) will evaluate these detector systems on the bench top and eventually in RASA systems to insure reliable and practical operation.

  2. Systems and methods for controlling energy use in a building management system using energy budgets

    DOE Patents [OSTI]

    Wenzel, Michael J; Drees, Kirk H

    2014-09-23

    Systems and methods for limiting power consumption by a heating, ventilation, and air conditioning (HVAC) subsystem of a building are shown and described. A feedback controller is used to generate a manipulated variable based on an energy use setpoint and a measured energy use. The manipulated variable may be used for adjusting the operation of an HVAC device.

  3. Building HVAC Requirements Overview Page 4-1 4 Building HVAC Requirements

    E-Print Network [OSTI]

    heating, radiant floor systems, evaporative cooling, gas cooling, ground-source heat pumps, and wood space.1.1 Introduction and Organization This chapter addresses the requirements for heating, ventilating, and air the following topics: 1. Heating Equipment. The first section addresses the requirements for heating equipment

  4. Deep Drilling Basic Research: Volume 5 - System Evaluations. Final Report, November 1988--August 1990

    SciTech Connect (OSTI)

    None

    1990-06-01

    This project is aimed at decreasing the costs and increasing the efficiency of drilling gas wells in excess of 15,000 feet. This volume presents a summary of an evaluation of various drilling techniques. Drilling solutions were compared quantitatively against typical penetration rates derived from conventional systems. A qualitative analysis measured the impact of a proposed system on the drilling industry. The evaluations determined that the best candidates f o r improving the speed and efficiency of drilling deep gas wells include: PDC/TSD bits, slim-hole drilling, roller-cone bits, downhole motors, top-driven systems, and coiled-tubing drilling.

  5. 28. annual offshore technology conference: Proceedings. Volume 4: Field drilling and development systems

    SciTech Connect (OSTI)

    1996-12-31

    The 88 papers in this volume cover the following topics: Small operator implementation of subsea technology; Control system umbilicals, components and ROV interfacing; DeepStar--Results and plans; Deepwater subsea manifold systems; Drilling technology; Limit state design criteria for pipelines; Liuhua project; Mobile offshore drilling units; Offshore coiled tubing operations; Oman-India gas pipeline; Paraffin and hydrate control; Pompano--A deepwater subsea development; Severe operating conditions; Subsea production systems; and Well completions technology. Papers have been processed separately for inclusion on the data base.

  6. Hot-gas cleanup system model development. Volume I. Final report

    SciTech Connect (OSTI)

    Ushimaru, K.; Bennett, A.; Bekowies, P.J.

    1982-11-01

    This two-volume report summarizes the state of the art in performance modeling of advanced high-temperature, high-pressure (HTHP) gas cleanup devices. Volume I contains the culmination of the research effort carried over the past 12 months and is a summary of research achievements. Volume II is the user's manual for the computer programs developed under the present research project. In this volume, Section 2 presents background information on pressurized, fluidized-bed combustion concepts, a description of the role of the advanced gas cleanup systems, and a list of advanced gas cleanup systems that are currently in development under DOE sponsorship. Section 3 describes the methodology for the software architecture that forms the basis of the well-disciplined and structured computer programs developed under the present project. Section 4 reviews the fundamental theories that are important in analyzing the cleanup performance of HTHP gas filters. Section 5 discusses the effect of alkali agents in HTHP gas cleanup. Section 6 evaluates the advanced HTHP gas cleanup models based on their mathematical integrity, availability of supporting data, and the likelihood of commercialization. As a result of the evaluation procedure detailed in Section 6, five performance models were chosen to be incorporated into the overall system simulation code, ASPEN. These five models (the electrocyclone, ceramic bag filter, moving granular bed filter, electrostatic granular bed filter, and electrostatic precipitator) are described in Section 7. The method of cost projection for these five models is discussed in Section 8. The supporting data and validation of the computer codes are presented in Section 9, and finally the conclusions and recommendations for the HTHP gas cleanup system model development are given in Section 10. 72 references, 19 figures, 25 tables.

  7. Solar/hydrogen systems for the 1985 to 2000 time frame. Volume I. Solar/hydrogen systems assessment. Final report

    SciTech Connect (OSTI)

    Foster, R. W.; Tison, R. R.; Escher, W. J.D.; Hanson, J. A.

    1980-06-01

    The findings of a study of opportunities for commercialization of systems capable of producing hydrogen from solar energy are presented in two volumes. A compendium of monographs by specialists in the fields of solar energy conversion technologies, hydrogen production technologies and related technology descriptions from the general literature comprise Volume II. This data base was used to support an evaluation and selection process that identified four candidate solar/hydrogen systems best suited to commercialization within the next two decades. Volume I first reviews the background of the work and the methods used. Then an evaluation of the hydrogen product costs that might be achieved by the four selected candidate systems (photovoltaic/water electrolysis, thermal-heat engine/water electrolysis, wind energy/water electrolysis, small hydrogen/water electrolysis) is compared with the pricing structure and practices of the commodity gas market. Subsequently, product cost and market price match is noted to exist in the small user sector of the hydrogen marketplace. Barriers to and historical time lags in, commercialization of new technologies are then reviewed. Finally, recommendations for development and demonstration programs designed to accelerate the commercialization of the candidate systems are presented.

  8. Deep Drilling Basic Research: Volume 4 - System Description. Final Report, November 1988--August 1990

    SciTech Connect (OSTI)

    Anderson, E.E.; Maurer, W.C.; Hood, M.; Cooper, G.; Cook, N.

    1990-06-01

    The first section of this Volume will discuss the ''Conventional Drilling System''. Today's complex arrangement of numerous interacting systems has slowly evolved from the very simple cable tool rigs used in the late 1800s. Improvements to the conventional drilling rig have varied in size and impact over the years, but the majority of them have been evolutionary modifications. Each individual change or improvement of this type does not have significant impact on drilling efficiency and economics. However, the change is almost certain to succeed, and over time--as the number of evolutionary changes to the system begin to add up--improvements in efficiency and economics can be seen. Some modifications, defined and described in this Volume as Advanced Modifications, have more than just an evolutionary effect on the conventional drilling system. Although the distinction is subtle, there are several examples of incorporated advancements that have had significantly more impact on drilling procedures than would a truly evolutionary improvement. An example of an advanced modification occurred in the late 1970s with the introduction of Polycrystalline Diamond Compact (PDC) drill bits. PDC bits resulted in a fundamental advancement in drilling procedures that could not have been accomplished by an evolutionary improvement in materials metallurgy, for example. The last drilling techniques discussed in this Volume are the ''Novel Drilling Systems''. The extent to which some of these systems have been developed varies from actually being tested in the field, to being no more than a theoretical concept. However, they all have one thing in common--their methods of rock destruction are fundamentally different from conventional drilling techniques. When a novel drilling system is introduced, it is a revolutionary modification of accepted drilling procedures and will completely replace current techniques. The most prominent example of a revolutionary modification in recent history was the complete displacement of cable tool rigs by rotary drilling rigs in the late 1920s.

  9. 1736 IEEE TRANSACTIONS ON COMMUNICATIONS, VOL. 51, NO. 10, OCTOBER 2003 Impulse Response of the HVAC Duct as a

    E-Print Network [OSTI]

    Stancil, Daniel D.

    of the HVAC Duct as a Communication Channel Pavel V. Nikitin, Member, IEEE, Daniel D. Stancil, Senior Member (HVAC) ducts in buildings behave as multimode waveguides when excited at radio frequencies and thus, can be used to distribute radio signals. The channel properties of the ducts are different from the properties

  10. Community energy systems and the law of public utilities. Volume thirty-four. New York

    SciTech Connect (OSTI)

    Feurer, D.A.; Weaver, C.L.

    1981-01-01

    A detailed description is presented of the laws and programs of the State of New York governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

  11. Community Energy Systems and the Law of Public Utilities. Volume Eight. Colorado

    SciTech Connect (OSTI)

    Feurer, D A; Weaver, C L

    1981-01-01

    A detailed description is given of the laws and programs of the State of Colorado governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

  12. Community Energy Systems and the Law of Public Utilities. Volume Nine. Connecticut

    SciTech Connect (OSTI)

    Feurer, D A; Weaver, C L

    1981-01-01

    A detailed description of the laws and programs of the State of Connecticut governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

  13. Community Energy Systems and the Law of Public Utilities. Volume Twenty-three. Massachusetts

    SciTech Connect (OSTI)

    Feurer, D.A.; Weaver, C.L.

    1981-01-01

    A detailed description is given of the laws and programs of the State of Massachusetts governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

  14. Community Energy Systems and the Law of Public Utilities. Volume Fifty-one. Wisconsin

    SciTech Connect (OSTI)

    Feurer, D.A.; Weaver, C.L.

    1981-01-01

    A detailed description is presented of the laws and programs of the State of Wisconsin governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

  15. Community Energy Systems and the Law of Public Utilities. Volume Fifty-two. Wyoming

    SciTech Connect (OSTI)

    Feurer, D.A.; Weaver, C.L.

    1981-01-01

    A detailed description is presented of the laws and programs of the State of Wyoming governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

  16. Community Energy Systems and the Law of Public Utilities. Volume Seven. California

    SciTech Connect (OSTI)

    Feurer, D A; Weaver, C L

    1981-01-01

    A detailed description is given of the laws and programs of the State of California governing the regulation of public energy utilities, the siting of energy generating and transmission facilities, the municipal franchising of public energy utilities, and the prescription of rates to be charged by utilities including attendant problems of cost allocations, rate base and operating expense determinations, and rate of return allowances. These laws and programs are analyzed to identify impediments which they may present to the implementation of Integrated Community Energy Systems (ICES). This report is one of fifty-one separate volumes which describe such regulatory programs at the Federal level and in each state as background to the report entitled Community Energy Systems and the Law of Public Utilities - Volume One: An Overview. This report also contains a summary of a strategy described in Volume One - An Overview for overcoming these impediments by working within the existing regulatory framework and by making changes in the regulatory programs to enhance the likelihood of ICES implementation.

  17. Solar Central Receiver Hybrid Power Systems sodium-cooled receiver concept. Final report. Volume III. Appendices

    SciTech Connect (OSTI)

    None

    1980-01-01

    The overall, long term objective of the Solar Central Receiver Hybrid Power System is to identify, characterize, and ultimately demonstrate the viability and cost effectiveness of solar/fossil, steam Rankine cycle, hybrid power systems that: (1) consist of a combined solar central receiver energy source and a nonsolar energy source at a single, common site, (2) may operate in the base, intermediate, and peaking capacity modes, (3) produce the rated output independent of variations in solar insolation, (4) provide a significant savings (50% or more) in fuel consumpton, and (5) produce power at the minimum possible cost in mills/kWh. It is essential that these hybrid concepts be technically feasible and economically competitive with other systems in the near to mid-term time period (1985-1990) on a commercial scale. The program objective for Phase I is to identify and conceptually characterize solar/fossil steam Rankine cycle, commercial-scale, power plant systems that are economically viable and technically feasible. This volume contains appendices to the conceptual design and systems analysis studies gien in Volume II, Books 1 and 2. (WHK)

  18. Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature? 

    E-Print Network [OSTI]

    Wei, G.; Turner, W. D.; Claridge, D.; Liu, M.

    2002-01-01

    The supply air temperature set point for a singleduct constant air volume air handling unit (AHU) system is often reset based on either return air temperature or outside air temperature in order to reduce simultaneous cooling and heating energy...

  19. Volume shrinkage effects on a planar integrated optical micro-channel system Christiane Gimkiewicz, Detlev Hagedorn, Jurgen Jahns

    E-Print Network [OSTI]

    Jahns, Jürgen

    shrinkage may occur while the replication process like hot embossing or injection molding, this shrinkageVolume shrinkage effects on a planar integrated optical micro-channel system Christiane Gimkiewicz

  20. Auto Defect Classification (ADC) Value for Patterned Wafer Inspection Systems in PLY Within a High Volume Wafer Manufacturing Fabrication Facility

    E-Print Network [OSTI]

    Durniak, John

    2010-05-14

    The purpose of this investigation is to demonstrate value for Auto Defect Classification (ADC) for patterned wafer inspection systems within a high volume manufacturing fabrication in the Process Limited Yield (PLY) defect area. Process excursions...

  1. Model documentation: Natural Gas Transmission and Distribution Model of the National Energy Modeling System; Volume 1

    SciTech Connect (OSTI)

    1994-02-24

    The Natural Gas Transmission and Distribution Model (NGTDM) is a component of the National Energy Modeling System (NEMS) used to represent the domestic natural gas transmission and distribution system. NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the Energy Information Administration (EIA) and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. This report documents the archived version of NGTDM that was used to produce the natural gas forecasts used in support of the Annual Energy Outlook 1994, DOE/EIA-0383(94). The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic design, provides detail on the methodology employed, and describes the model inputs, outputs, and key assumptions. It is intended to fulfill the legal obligation of the EIA to provide adequate documentation in support of its models (Public Law 94-385, Section 57.b.2). This report represents Volume 1 of a two-volume set. (Volume 2 will report on model performance, detailing convergence criteria and properties, results of sensitivity testing, comparison of model outputs with the literature and/or other model results, and major unresolved issues.) Subsequent chapters of this report provide: (1) an overview of the NGTDM (Chapter 2); (2) a description of the interface between the National Energy Modeling System (NEMS) and the NGTDM (Chapter 3); (3) an overview of the solution methodology of the NGTDM (Chapter 4); (4) the solution methodology for the Annual Flow Module (Chapter 5); (5) the solution methodology for the Distributor Tariff Module (Chapter 6); (6) the solution methodology for the Capacity Expansion Module (Chapter 7); (7) the solution methodology for the Pipeline Tariff Module (Chapter 8); and (8) a description of model assumptions, inputs, and outputs (Chapter 9).

  2. Thermal Storage with Conventional Cooling Systems 

    E-Print Network [OSTI]

    McGee, E. E.

    1990-01-01

    "Thermal Storage" is a term that describes a mechanical systems ability to sustain normal HVAC operations through a thermal retention source. This system allows for the curtailment of operating major refrigeration equipment during periods of high kw...

  3. Hybrid Parallelism for Volume Rendering on Large, Multi-core Systems

    E-Print Network [OSTI]

    Howison, Mark

    2010-01-01

    W. , and Childs, H. (2010) MPI-hybrid parallelism for volumeHybrid Parallelism for Volume Rendering on Large, Multi-corecharacteristics of “hybrid” parallel program- ming and

  4. Transportation Sector Model of the National Energy Modeling System. Volume 2 -- Appendices: Part 1

    SciTech Connect (OSTI)

    1998-01-01

    This volume contains input data and parameters used in the model of the transportation sector of the National Energy Modeling System. The list of Transportation Sector Model variables includes parameters for the following: Light duty vehicle modules (fuel economy, regional sales, alternative fuel vehicles); Light duty vehicle stock modules; Light duty vehicle fleet module; Air travel module (demand model and fleet efficiency model); Freight transport module; Miscellaneous energy demand module; and Transportation emissions module. Also included in these appendices are: Light duty vehicle market classes; Maximum light duty vehicle market penetration parameters; Aircraft fleet efficiency model adjustment factors; and List of expected aircraft technology improvements.

  5. Model Code for the Control of Residential HVAC Distribution System Leakage and HVAC-Induced Building Leakage 

    E-Print Network [OSTI]

    Wemhoff, P.

    1990-01-01

    , and nonmetallic flexible duct. Also addressed are (1) detailed requirements for the sealing of mechanical closets when they function as plenum chambers, (2) detailed requirements for the sealing of enclosed support platforms or air handlers and furnaces when...

  6. Technical and economic assessment of fluidized bed augmented compressed air energy storage system. Volume III. Preconceptual design

    SciTech Connect (OSTI)

    Giramonti, A.J.; Lessard, R.D.; Merrick, D.; Hobson, M.J.

    1981-09-01

    A technical and economic assessment of fluidized bed combustion augmented compressed air energy storage systems is presented. The results of this assessment effort are presented in three volumes. Volume III - Preconceptual Design contains the system analysis which led to the identification of a preferred component configuration for a fluidized bed combustion augmented compressed air energy storage system, the results of the effort which transformed the preferred configuration into preconceptual power plant design, and an introductory evaluation of the performance of the power plant system during part-load operation and while load following.

  7. Fouling of HVAC Fin and Tube Heat Exchangers Jeffrey Siegel and Van P. Carey

    E-Print Network [OSTI]

    LBNL-47668 Fouling of HVAC Fin and Tube Heat Exchangers Jeffrey Siegel and Van P. Carey FIN AND TUBE HEAT EXCHANGERS Jeffrey Siegel1,2 and Van P. Carey2 1 Lawrence Berkeley National, USA; E-mail: vcarey@euler.me.berkeley.edu ABSTRACT Fin and tube heat exchangers are used widely

  8. Assessment of solar options for small power systems applications. Volume III. Analysis of concepts

    SciTech Connect (OSTI)

    Laity, W.W.; Aase, D.T.; Apley, W.J.; Bird, S.P.; Drost, M.K.; Garrett-Price, B.A.; Williams, T.A.

    1980-09-01

    A comparative analysis of solar thermal conversion concepts that are potentially suitable for development as small electric power systems (1 to 10 MWe) is given. Seven generic types of collectors, together with associated subsystems for electric power generation, were considered. The collectors can be classified into three categories: (1) two-axis tracking (with compound-curvature reflecting surfaces; (2) one-axis tracking (with single-curvature reflecting suraces; and (3) nontracking (with low-concentration reflecting surfaces). All seven collectors were analyzed in conceptual system configurations with Rankine-cycle engines. In addition, two of the collectors (the Point Focus Central Receiver and the Point Focus Distributed Receiver) were analyzed with Brayton-cycle engines, and the latter of the two also was analyzed with Stirling-cycle engines. This volume describes the systems analyses performed on all the alternative configurations of the seven generic collector concepts and the results obtained. The SOLSTEP computer code used to determine each configuration's system cost and performance is briefly described. The collector and receiver performance calculations used are also presented. The capital investment and related costs that were obtained from the systems studies are presented, and the levelized energy costs are given as a function of capacity factor obtained from the systems studies. Included also are the values of the other attributes used in the concepts' final ranking. The comments, conclusions, and recommendations developed by the PNL study team during the concept characterization and systems analysis tasks of the study are presented. (WHK)

  9. Two-nucleon systems in a finite volume. II. S13-D13 coupled channels and the deuteron

    SciTech Connect (OSTI)

    Briceno, Raul [JLAB; Davoudi, Zohreh [Washington U.; Luu, Thomas C. [Forschungszentrum Jülich; Savage, Martin J. [Washington U.

    2013-12-01

    The energy spectra of two nucleons in a cubic volume provide access to the two phase shifts and one mixing angle that define the S matrix in the S13-D13 coupled channels containing the deuteron. With the aid of recently derived energy quantization conditions for such systems, and the known scattering parameters, these spectra are predicted for a range of volumes. It is found that extractions of the infinite-volume deuteron binding energy and leading scattering parameters, including the S-D mixing angle at the deuteron pole, are possible from lattice QCD calculations of two-nucleon systems with boosts of |P|?2?/L{radical}3 in volumes with 10??fm?L?14??fm. The viability of extracting the asymptotic D/S ratio of the deuteron wave function from lattice QCD calculations is discussed.

  10. Idaho Field Experiment 1981. Volume 1. Experimental design and measurement systems

    SciTech Connect (OSTI)

    Start, G E; Cate, J H; Dickson, C R; Sagendorf, J F; Ackermann, G R

    1983-10-01

    The Idaho Field Experiment is reported in three volumes and supplemented by special contractor reports. Volume I describes the design and goals of the measurement program and the measurement systems utilized during the field program. The measurement systems layouts are described as well. The 1981 Idaho Field Experiment was conducted in South East Idaho over the Upper Snake River Plain. Nine test-day case studies were measured between July 15 and 30, 1981. Eight-hour releases of SF/sub 6/ gaseous tracer were made from 46 m above ground. Tracer was sampled hourly, for 12 sequential hours, at about 100 locations within an area 24 km square. Also, a single total integrated sample, of about 30 hours duration, was collected at approximately 100 sites within an area 48 by 72 km (using 6 km spacings). Extensive tower profiles of meteorology at the release point were collected. RAWINSONDES, RABALS and PIBALS were collected at 3 to 5 sites. Horizontal, low-altitude winds were monitored using the INEL MESONET. SF/sub 6/ tracer plumes were marked with co-located oil fog releases and bi-hourly sequential launches of tetroon pairs. Aerial LIDAR observations of the oil fog plume and airborne samples of SF/sub 6/ were collected. High-altitude aerial photographs of daytime plumes were also collected. 10 references, 14 figures, 5 tables.

  11. Hybrid Parallelism for Volume Rendering on Large, Multi-core Systems

    SciTech Connect (OSTI)

    Howison, Mark; Bethel, E. Wes; Childs, Hank

    2010-07-12

    This work studies the performance and scalability characteristics of"hybrid'"parallel programming and execution as applied to raycasting volume rendering -- a staple visualization algorithm -- on a large, multi-core platform. Historically, the Message Passing Interface (MPI) has become the de-facto standard for parallel programming and execution on modern parallel systems. As the computing industry trends towards multi-core processors, with four- and six-core chips common today and 128-core chips coming soon, we wish to better understand how algorithmic and parallel programming choices impact performance and scalability on large, distributed-memory multi-core systems. Our findings indicate that the hybrid-parallel implementation, at levels of concurrency ranging from 1,728 to 216,000, performs better, uses a smaller absolute memory footprint, and consumes less communication bandwidth than the traditional, MPI-only implementation.

  12. MPI-hybrid Parallelism for Volume Rendering on Large, Multi-core Systems

    SciTech Connect (OSTI)

    Howison, Mark; Bethel, E. Wes; Childs, Hank

    2010-03-20

    This work studies the performance and scalability characteristics of"hybrid'" parallel programming and execution as applied to raycasting volume rendering -- a staple visualization algorithm -- on a large, multi-core platform. Historically, the Message Passing Interface (MPI) has become the de-facto standard for parallel programming and execution on modern parallel systems. As the computing industry trends towards multi-core processors, with four- and six-core chips common today and 128-core chips coming soon, we wish to better understand how algorithmic and parallel programming choices impact performance and scalability on large, distributed-memory multi-core systems. Our findings indicate that the hybrid-parallel implementation, at levels of concurrency ranging from 1,728 to 216,000, performs better, uses a smaller absolute memory footprint, and consumes less communication bandwidth than the traditional, MPI-only implementation.

  13. Hybrid Parallelism for Volume Rendering on Large, Multi-core Systems

    SciTech Connect (OSTI)

    Howison, Mark; Bethel, E. Wes; Childs, Hank

    2010-06-14

    This work studies the performance and scalability characteristics of"hybrid" parallel programming and execution as applied to raycasting volume rendering -- a staple visualization algorithm -- on a large, multi-core platform. Historically, the Message Passing Interface (MPI) has become the de-facto standard for parallel programming and execution on modern parallel systems. As the computing industry trends towards multi-core processors, with four- and six-core chips common today and 128-core chips coming soon, we wish to better understand how algorithmic and parallel programming choices impact performance and scalability on large, distributed-memory multi-core systems. Our findings indicate that the hybrid-parallel implementation, at levels of concurrency ranging from 1,728 to 216,000, performs better, uses a smaller absolute memory footprint, and consumes less communication bandwidth than the traditional, MPI-only implementation.

  14. Volume 67A, number 5,6 PHYSICS LETTERS 4 September 1978 POSITION OPERATORS FOR SYSTEMS EXHIBITING

    E-Print Network [OSTI]

    O'Connell, Robert F.

    Volume 67A, number 5,6 PHYSICS LETTERS 4 September 1978 POSITION OPERATORS FOR SYSTEMS EXHIBITING and arbitrary spin s, as an elementary system, the choice ofposition operator well as systemsof zero mass shown [1] that if theposition operator is definedas in ref. [21, themovementof the mean position ofa

  15. High-Performance Home Technologies: Solar Thermal & Photovoltaic Systems; Volume 6 Building America Best Practices Series

    SciTech Connect (OSTI)

    2007-06-01

    The sixth volume of the Building America Best Practices Series presents information that is useful throughout the U.S. for enhancing the energy efficiency practices in the specific climate zones that are presented in each of the volumes.

  16. Improving Energy Efficiency by Developing Components for Distributed Cooling and Heating Based on Thermal Comfort Modeling[Thermoelectric (TE) HVAC

    Broader source: Energy.gov [DOE]

    Discusses results from TE HVAC project to add detail to a human thermal comfort model and further allow load reduction in the climate control energy through a distributed TE network

  17. Proceedings of the seventh annual gasification and gas stream cleanup systems contractors review meeting: Volume 2

    SciTech Connect (OSTI)

    Ghate, M.R.; Markel, K.E. Jr.; Jarr, L.A.; Bossart, S.J.

    1987-08-01

    On June 16 through 19, 1987, METC sponsored the Seventh Annual Gasification and Gas Stream Cleanup Systems Contractors Review Meeting which was held at the Sheraton Lakeview Conference Center in Morgantown, West Virginia. The primary purpose of the meeting was threefold: to review the technical progress and current status of the gasification and gas stream cleanup projects sponsored by the Department of Energy; to foster technology exchange among participating researchers and other technical communities; to facilitate interactive dialogues which would identify research needs that would make coal-based gasification systems more attractive economically and environmentally. More than 310 representatives of Government, academia, industry, and foreign energy research organizations attended the 4-day meeting. Fifty-three papers and thirty poster dsplays were presented summarizing recent developments in the gasification and gas stream cleanup programs. Volume II covers papers presented at sessions 5 and 6 on system for the production of synthesis gas, and on system for the production of power. All papers have been processed for inclusion in the Energy Data Base.

  18. Building and Environment 42 (2007) 203217 Model-based analysis and simulation of airflow control systems of

    E-Print Network [OSTI]

    Melnik, Roderick

    2007-01-01

    extracted from the room, and the temperature of the air exited of heat exchanger and supplied from for two different types of loading conditions. r 2005 Elsevier Ltd. All rights reserved. Keywords: HVAC, testing, operation, and management of heating, ventilation and air conditioning (HVAC) systems rely

  19. Impact Factors for Microinvasion in Intrahepatic Cholangiocarcinoma: A Possible System for Defining Clinical Target Volume

    SciTech Connect (OSTI)

    Bi Aihong [Department of Radiation Oncology, Zhongshan Hospital, Fudan University, Shanghai (China); Zeng Zhaochong, E-mail: zeng.zhaochong@zs-hospital.sh.c [Department of Radiation Oncology, Zhongshan Hospital, Fudan University, Shanghai (China); Ji Yuan; Zeng Haiying; Xu Chen [Department of Pathology, Zhongshan Hospital, Fudan University, Shanghai (China); Tang Zhaoyou; Fan Jia; Zhou Jian [Liver Cancer Institute, Zhongshan Hospital, Fudan University, Shanghai (China); Zeng Mengsu [Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai (China); Tan Yunshan [Department of Pathology, Zhongshan Hospital, Fudan University, Shanghai (China)

    2010-12-01

    Purpose: To quantify microscopic invasion of intrahepatic cholangiocarcinoma (IHC) into nontumor tissue and define the gross tumor volume (GTV)-to-clinical target volume (CTV) expansion necessary for radiotherapy. Methods and Materials: One-hundred IHC patients undergoing radical resection from January 2004 to July 2008 were enrolled in this study. Pathologic and clinical data including maximum tumor diameter, tumor boundary type, TNM stage, histologic grade, tumor markers, and liver enzymes were reviewed. The distance of microinvasion from the tumor boundary was measured by microscopy. The contraction coefficient for tumor measurements in radiographs and slide-mounted tissue was calculated. SPSS15.0 was used for statistical analysis. Results: Sixty-five patients (65%) exhibited tumor microinvasions. Microinvasions ranged from 0.4-8 mm, with 96% of patients having a microinvasion distance {<=}6 mm measured on slide. The radiograph-to-slide contraction coefficient was 82.1%. The degree of microinvasion was correlated with tumor boundary type, TNM stage, histologic grade, and serum levels of carbohydrate antigen 19-9, alanine aminotransferase, aspartate aminotransferase, {gamma}-glutamyltransferase and alkaline phosphatase. To define CTV accurately, we devised a scoring system based on combination of these factors. According to this system, a score {<=}1.5 is associated with 96.1% sensitivity in detecting patients with a microextension {<=}4.9 mm in radiographs, whereas a score {>=}2 has a 95.1% sensitivity in detecting microextension {<=}7.9 mm measured on radiograph. Conclusions: Patients with a score {<=}1.5 and {>=}2 require a radiographic GTV-to-CTV expansions of 4.9 and 7.9 mm, respectively, to encompass >95% of microinvasions.

  20. Best Practices for Energy Efficient Cleanrooms: Control of Chilled Water System

    E-Print Network [OSTI]

    : Control of chilled water system Tengfang Xu Contents HVAC WATER SYSTEMSLBNL-58635 Best Practices for Energy Efficient Cleanrooms: Control of Chilled Water System Tengfang.............................................................................................. 2 Control of chilled water system

  1. Improving Building Control and System Operation Through the Continuous Commissioning® Process: A Case Study 

    E-Print Network [OSTI]

    Redmann, N.; Liu, M.

    2003-01-01

    , and Energy Management and Control System (EMCS) functionality. It also aided in the identification of mechanical systems needing repair. The optimization of the HVAC systems and advanced utilization of the EMCS reduced the combined heating and cooling energy...

  2. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Control modules -- Volume 1, Revision 4

    SciTech Connect (OSTI)

    Landers, N.F.; Petrie, L.M.; Knight, J.R.

    1995-04-01

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. This manual is divided into three volumes: Volume 1--for the control module documentation, Volume 2--for the functional module documentation, and Volume 3 for the documentation of the data libraries and subroutine libraries.

  3. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Miscellaneous -- Volume 3, Revision 4

    SciTech Connect (OSTI)

    Petrie, L.M.; Jordon, W.C.; Edwards, A.L. |

    1995-04-01

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice; (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System developments has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. This manual is divided into three volumes: Volume 1--for the control module documentation, Volume 2--for the functional module documentation, and Volume 3--for the data libraries and subroutine libraries.

  4. Duct leakage impacts on VAV system performance in California large commercial buildings

    SciTech Connect (OSTI)

    Wray, Craig P.; Matson, Nance E.

    2003-10-01

    The purpose of this study is to evaluate the variability of duct leakage impacts on air distribution system performance for typical large commercial buildings in California. Specifically, a hybrid DOE-2/TRNSYS sequential simulation approach was used to model the energy use of a low-pressure terminal-reheat variable-air-volume (VAV) HVAC system with six duct leakage configurations (tight to leaky) in nine prototypical large office buildings (representing three construction eras in three California climates where these types of buildings are common). Combined fan power for the variable-speed-controlled supply and return fans at design conditions was assumed to be 0.8 W/cfm. Based on our analyses of the 54 simulation cases, the increase in annual fan energy is estimated to be 40 to 50% for a system with a total leakage of 19% at design conditions compared to a tight system with 5% leakage. Annual cooling plant energy also increases by about 7 to 10%, but reheat energy decreases (about 3 to 10%). In combination, the increase in total annual HVAC site energy is 2 to 14%. The total HVAC site energy use includes supply and return fan electricity consumption, chiller and cooling tower electricity consumption, boiler electricity consumption, and boiler natural gas consumption. Using year 2000 average commercial sector energy prices for California ($0.0986/kWh and $7.71/Million Btu), the energy increases result in 9 to 18% ($7,400 to $9,500) increases in HVAC system annual operating costs. Normalized by duct surface area, the increases in annual operating costs are 0.14 to 0.18 $/ft{sup 2}. Using a suggested one-time duct sealing cost of $0.20 per square foot of duct surface area, these results indicate that sealing leaky ducts in VAV systems has a simple payback period of about 1.3 years. Even with total leakage rates as low as 10%, duct sealing is still cost effective. This suggests that duct sealing should be considered at least for VAV systems with 10% or more total duct leakage. The VAV system that we simulated had perfectly insulated ducts, and maintained constant static pressure in the ducts upstream of the VAV boxes and a constant supply air temperature at the airhandler. Further evaluations of duct leakage impacts should be carried out in the future after methodologies are developed to deal with duct surface heat transfer effects, to deal with airflows entering VAV boxes from ceiling return plenums (e.g., to model parallel fan-powered VAV boxes), and to deal with static pressure reset and supply air temperature reset strategies.

  5. Systems and methods for controlling energy use in a building management system using energy budgets

    SciTech Connect (OSTI)

    Wenzel, Michael J.

    2012-06-17

    Systems and methods for limiting power consumption by a heating, ventilation, and air conditioning (HVAC) subsystem of a building are shown and described. A mathematical linear operator is found that transforms the unused or deferred cooling power usage of the HVAC system based on pre-determined temperature settings to a target cooling power usage. The mathematical operator is applied to the temperature settings to create a temperature setpoint trajectory expected to provide the target cooling power usage.

  6. Feasibility of developing a portable driver performance data acquisition system for human factors research: Design specifications. Volume 3

    SciTech Connect (OSTI)

    Carter, R.J.; Barickman, F.S.

    1998-01-01

    A two-phase, multi-year research program entitled ``development of a portable driver performance data acquisition system for human factors research was recently completed. The primary objective of the project was to develop a portable data acquisition system for crash avoidance research (DASCAR) that will allow driver performance data to be collected using a large variety of vehicle types and that would be capable of being installed on a given vehicle type within a relatively short-time frame. During Phase 1 a feasibility study for designing and fabricating DASCAR was conducted. In phase 2 of the research DASCAR was actually developed and validated. This technical memorandum documents the results from the feasibility study. It is subdivided into three volumes. Volume one addresses the last five items in the phase 1 research and the first issue in the second phase of the project. Volume 2 presents the related appendices. Volume three (this report) displays the design specifications developed for DASCAR during the ``develop design requirements and specifications for a portable driver performance data acquisition system`` task. Design specifications were assembled for each DASCAR element. The specifications were prepared in sufficient detail to allow a third party to use them to design, develop, procure, and subsequently construct the data acquisition system. This report also covers the background to the program.

  7. VOLUME 71, NUMBER 19 PHYSICAL REVIEW LETTERS 8 NOVEMBER 1993 Non-Gaussian Energy Level Statistics for Some Integrable Systems

    E-Print Network [OSTI]

    Bleher, Pavel

    VOLUME 71, NUMBER 19 PHYSICAL REVIEW LETTERS 8 NOVEMBER 1993 Non-Gaussian Energy Level Statistics statistics [1,4). We first describe the results informally in the language of energy levels and then give with energy less than E of an integrable quantum system with two degrees of freedom is equal to XE+sE', where

  8. GENII (Generation II): The Hanford Environmental Radiation Dosimetry Software System: Volume 3, Code maintenance manual: Hanford Environmental Dosimetry Upgrade Project

    SciTech Connect (OSTI)

    Napier, B.A.; Peloquin, R.A.; Strenge, D.L.; Ramsdell, J.V.

    1988-09-01

    The Hanford Environmental Dosimetry Upgrade Project was undertaken to incorporate the internal dosimetry models recommended by the International Commission on Radiological Protection (ICRP) in updated versions of the environmental pathway analysis models used at Hanford. The resulting second generation of Hanford environmental dosimetry computer codes is compiled in the Hanford Environmental Dosimetry System (Generation II, or GENII). This coupled system of computer codes is intended for analysis of environmental contamination resulting from acute or chronic releases to, or initial contamination of, air, water, or soil, on through the calculation of radiation doses to individuals or populations. GENII is described in three volumes of documentation. This volume is a Code Maintenance Manual for the serious user, including code logic diagrams, global dictionary, worksheets to assist with hand calculations, and listings of the code and its associated data libraries. The first volume describes the theoretical considerations of the system. The second volume is a Users' Manual, providing code structure, users' instructions, required system configurations, and QA-related topics. 7 figs., 5 tabs.

  9. 552 nature neuroscience volume 5 no 6 june 2002 To understand the problems the nervous system faces in analyzing

    E-Print Network [OSTI]

    Hooper, Scott

    552 nature neuroscience · volume 5 no 6 · june 2002 To understand the problems the nervous system; in the studies described here we investigated the neur- al mechanism underlying this ability. Neurons that fire- lus, thalamus and cortex3­5. Three types of duration-sensitive neuron are known: low-pass (which fire

  10. Modeling water uptake by a root system growing in a fixed soil volume

    E-Print Network [OSTI]

    Albrieu, J L Blengino; Tarzia, D A

    2015-01-01

    The water uptake by roots of plants is examined for an ideal situation, with an approximation that resembles plants growing in pots, meaning that the total soil volume is fixed. We propose a coupled water uptake-root growth model. A one-dimensional model for water flux and water uptake by a root system growing uniformly distributed in the soil is presented, and the Van Genuchten model for the transport of water in soil is used. The governing equations are represented by a moving boundary model for which the root length, as a function of time, is prescribed. The solution of the model is obtained by front-fixing and finite element methods. Model predictions for water uptake by a same plant growing in loam, silt and clay soils are obtained and compared. A sensitivity analysis to determine relative effects on water uptake when system parameters are changed is also presented and shows that the model and numerical method proposed are more sensitive to the root growth rate than to the rest of the parameters. This se...

  11. Advanced systems demonstration for utilization of biomass as an energy source. Volume II. Technical specifications

    SciTech Connect (OSTI)

    1980-10-01

    This volume contains all of the technical specifications relating to materials and construction of the biomass cogeneration facility in the state of Maine. (DMC)

  12. Hybrid Parallelism for Volume Rendering on Large, Multi-core Systems

    E-Print Network [OSTI]

    Howison, Mark

    2010-01-01

    Hybrid Parallelism for Volume Rendering on Large, Multi-corendings indicate that the hybrid-parallel implementation, atpassing against a “hybrid” parallel im- plementation, which

  13. DISTRIBUTED ENERGY SYSTEMS IN CALIFORNIA'S FUTURE: A PRELIMINARY REPORT, VOLUME I

    E-Print Network [OSTI]

    Authors, Various

    2010-01-01

    on Nuclear and Alternative Energy Strategies (CONAES), draftVolume 5, Status of Alternative Energy Technologies, 1977on Nuclear and Alternative Energy Strategies (CONAES), draft

  14. Nuclear proliferation and civilian nuclear power. Report of the Nonproliferation Alternative Systems Assessment Program. Volume IV. Commercial potential

    SciTech Connect (OSTI)

    Not Available

    1980-06-01

    This volume of the Nonproliferation Alternative Systems Assessment Program (NASAP) report provides time and cost estimates for positioning new nuclear power systems for commercial deployment. The assessment also estimates the rates at which the new systems might penetrate the domestic market, assuming the continuing viability of the massive light-water reactor network that now exists worldwide. This assessment does not recommend specific, detailed program plans and budgets for individual systems; however, it is clear from this analysis that any of the systems investigated could be deployed if dictated by national interest.

  15. Assessment of Energy Storage Alternatives in the Puget Sound Energy System Volume 2: Energy Storage Evaluation Tool

    SciTech Connect (OSTI)

    Wu, Di; Jin, Chunlian; Balducci, Patrick J.; Kintner-Meyer, Michael CW

    2013-12-01

    This volume presents the battery storage evaluation tool developed at Pacific Northwest National Laboratory (PNNL), which is used to evaluate benefits of battery storage for multiple grid applications, including energy arbitrage, balancing service, capacity value, distribution system equipment deferral, and outage mitigation. This tool is based on the optimal control strategies to capture multiple services from a single energy storage device. In this control strategy, at each hour, a look-ahead optimization is first formulated and solved to determine battery base operating point. The minute by minute simulation is then performed to simulate the actual battery operation. This volume provide background and manual for this evaluation tool.

  16. This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research

    E-Print Network [OSTI]

    Kusiak, Andrew

    , ventilation, and air conditioning (HVAC) system in an office building is presented. A neural network (NN reserved. 1. Introduction Heating, ventilating, and air conditioning (HVAC) systems, account for over 50 air volume air conditioning system using a genetic algorithm. HVAC systems are complex, nonlinear

  17. June 9, 2010 12:39 World Scientific Review Volume -9in x 6in ComplexAndEconophisics5 Introduction to Complex and Econophysics Systems

    E-Print Network [OSTI]

    Aste, Tomaso

    June 9, 2010 12:39 World Scientific Review Volume - 9in x 6in ComplexAndEconophisics5 Chapter 1 Notes in Complex Systems Vol.9 (World Scientific, Singapore 2010) pag.1- 35. This Chapter of complex system, but if we 1 #12;June 9, 2010 12:39 World Scientific Review Volume - 9in x 6in Complex

  18. 96 ASHRAE Transactions: Research Current duct design methods for variable air volume

    E-Print Network [OSTI]

    -round electrical energy cost of the fan. The initial cost of the fan is not included. The calculation procedure to determine duct sizes, overall system pressure drop, and fan energy cost. However, in VAV systems for effective, energy-efficient, and comfortable heating, ventilat- ing, and air-conditioning (HVAC) systems

  19. Proceedings of the 1996 spring technical conference of the ASME Internal Combustion Engine Division. Volume 2: Engine design and engine systems; ICE-Volume 26-2

    SciTech Connect (OSTI)

    Uzkan, T.

    1996-12-31

    Although the cost of the petroleum crude has not increased much within the last decade, the drive to develop internal combustion engines is still continuing. The basic motivation of this drive is to reduce both emissions and costs. Recent developments in computer chip production and information management technology have opened up new applications in engine controls and monitoring. The development of new information is continuing at a rapid pace. Some of these research and development results were presented at the 1996 Spring Technical Conference of the ASME Internal Combustion Engine Division in Youngstown, Ohio, April 21--24, 1996. The papers presented covered various aspects of the design, development, and application of compression ignition and spark ignition engines. The conference was held at the Holiday Inn Metroplex Complex and hosted by Altronic Incorporated of Girard, Ohio. The written papers submitted to the conference have been published in three conference volumes. Volume 2 includes the papers on the topics of engine design, engine systems, and engine user experience.

  20. Finite Volume Based Computer Program for Ground Source Heat Pump System

    SciTech Connect (OSTI)

    Menart, James A.

    2013-02-22

    This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled ?Finite Volume Based Computer Program for Ground Source Heat Pump Systems.? The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump. The price paid for the three-dimensional detail is the large computational times required with GEO3D. The computational times required for GEO2D are reasonable, a few minutes for a 20 year simulation. For a similar simulation, GEO3D takes days of computational time. Because of the small simulation times with GEO2D, a number of attractive features have been added to it. GEO2D has a user friendly interface where inputs and outputs are all handled with GUI (graphical user interface) screens. These GUI screens make the program exceptionally easy to use. To make the program even easier to use a number of standard input options for the most common GSHP situations are provided to the user. For the expert user, the option still exists to enter their own detailed information. To further help designers and GSHP customers make decisions about a GSHP heating and cooling system, cost estimates are made by the program. These cost estimates include a payback period graph to show the user where their GSHP system pays for itself. These GSHP simulation tools should be a benefit to the advancement of GSHP systems.

  1. Recovery Act: Finite Volume Based Computer Program for Ground Source Heat Pump Systems

    SciTech Connect (OSTI)

    James A Menart, Professor

    2013-02-22

    This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled ���¢��������Finite Volume Based Computer Program for Ground Source Heat Pump Systems.���¢������� The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump. The price paid for the three-dimensional detail is the large computational times required with GEO3D. The computational times required for GEO2D are reasonable, a few minutes for a 20 year simulation. For a similar simulation, GEO3D takes days of computational time. Because of the small simulation times with GEO2D, a number of attractive features have been added to it. GEO2D has a user friendly interface where inputs and outputs are all handled with GUI (graphical user interface) screens. These GUI screens make the program exceptionally easy to use. To make the program even easier to use a number of standard input options for the most common GSHP situations are provided to the user. For the expert user, the option still exists to enter their own detailed information. To further help designers and GSHP customers make decisions about a GSHP heating and cooling system, cost estimates are made by the program. These cost estimates include a payback period graph to show the user where their GSHP system pays for itself. These GSHP simulation tools should be a benefit to the advancement of GSHP system

  2. Building America Webinar: High Performance Space Conditioning Systems, Part II

    Broader source: Energy.gov [DOE]

    The webinar will continue our series on strategies to improve the performance of HVAC systems for low load homes and home performance retrofits. Presenters and specific topics for this webinar...

  3. Building America Webinar: High Performance Space Conditioning Systems, Part I

    Broader source: Energy.gov [DOE]

    The webinar will focus on strategies to improve the performance of HVAC systems for low load homes and home performance retrofits. Presenters and specific topics for this webinar will be:

  4. Applications of Optimal Building Energy System Selection and Operation

    E-Print Network [OSTI]

    Marnay, Chris

    2014-01-01

    PDP: Peak Day Pricing PV: solar photovoltaic systems SaaS:Software as a Service ST: solar thermal SVOW: StorageEnvironmental Performance of a Solar-Thermal-Assisted HVAC

  5. Applications of Optimal Building Energy System Selection and Operation

    E-Print Network [OSTI]

    Marnay, Chris

    2014-01-01

    solar thermal SVOW: Storage Viability Web Service UCD: University of California, Davis campus, near Sacramento UNM: University of New Mexico,solar-assisted heating ventilation and air conditioning (HVAC) system of a University of New Mexico (

  6. Optimal Control of Harvesting Ice Thermal Storage Systems 

    E-Print Network [OSTI]

    Knebel, D. E.

    1988-01-01

    Thermal storage is becoming a standard consideration in HVAC and process cooling systems. As the technology is refined, more attention is being given to minimize the energy consumption and power demand requirements. This paper addresses a method...

  7. Systems Description; Sperry Low Temperature Geothermal Conversion System - Phase I and Phase II; Final Report, Volume III

    SciTech Connect (OSTI)

    Matthews, Hugh B.

    1982-01-01

    This Volume should be considered the introductory volume to the series of six volumes even though numbered out of sequence. Volumes I and II were completed first and released in 1981 while a staff member was available to do the work. Volumes III through VI are being written and released some two years later as DOE funding became available for the purpose. They are as complete as possible considering that almost all the people involved in the program are now unavailable. This Volume III is an overview of the entire program, and many of the items presented herein briefly will be found in expanded form in one of the other five volumes. It will be noticed that assumptions and parameters such as well flow, well temperature, wet bulb temperatures, etc., involved in the several different performance calculations in the volume vary somewhat. These calculations were made at different times for different purposes and no attempt has been made to bring them into exact agreement.

  8. DOE ZERH Webinar: Low Load High Efficiency HVAC

    Broader source: Energy.gov [DOE]

    Zero Energy Ready Homes have advanced insulation and draft sealing that reduce energy consumption and enable the design and installation of an engineered comfort system that is significantly...

  9. EECBG Success Story: HVAC Upgrade Saving Money, Protecting History...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Saving Money, Protecting History November 2, 2010 - 5:37pm Addthis A new heating and cooling system at Chester County Historical Societys history center is saving the...

  10. Indirect Benefits (Increased Roof Life and HVAC Savings) from...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    a decision on the PV installation, the Department of Energy Tiger Team has investigated potential indirect benefits of installing a solar PV system on the Convention Center roof....

  11. Lean Implementation Considerations in Factory Operations of Low Volume/High Complexity Production Systems

    E-Print Network [OSTI]

    Shields, Thomas J.

    The researchers of the Lean Aircraft Initiative developed a hypothesized lean implementation model seeking to provide its members guidance on implementing lean transitions in factory operations of low volume/high complexity ...

  12. Room Temperature Control During Season Switchover with Single Duct Variable Air Volume System Without Reheat 

    E-Print Network [OSTI]

    Liu, C.; Deng, S.; Claridge, D. E.; Turner, W. D.; Bruner, H.

    2003-01-01

    The Langford “A” building houses the College of Architecture on TAMU campus. There are ten singleduct variable air volume (VAV) air-handling units (AHUs) without reheat serving the building. The local pneumatic thermostats modulate the dampers...

  13. A flexible assembly system for low volume and high diversity production

    E-Print Network [OSTI]

    Schwenke, Richard Clemens

    2009-01-01

    This thesis project seeks to optimize floor layouts for semiconductor equipment assembly operations. The assembly of semiconductor equipment is characterized by low volume and high product diversity and complexity. Demand ...

  14. 27. Annual Offshore Technology Conference: 1995 Proceedings. Volume 4: Field drilling and development systems

    SciTech Connect (OSTI)

    1995-12-31

    This conference proceedings represents volume 4 of a four volume set of offshore oil and gas operation and development. This proceedings includes papers dealing with subsea flowlines and connectors; well completion practices; new technologies associated with subsea wellheads; multiphase flow pumping and flow meters; and materials testing procedures for well tubulars. It also has a section on the overall technology utilization in developing the offshore areas of Brazil and Norway.

  15. BULGARIAN ACADEMY OF SCIENCES CYBERNETICS AND INFORMATION TECHNOLOGIES Volume 7, No 1

    E-Print Network [OSTI]

    Borissova, Daniela

    , electrical heating, co-generation (gas turbine, diesels). To integrate subsystems with various functions 2007 HVAC Control via Hybrid Intelligent Systems Mincho Hadjiski1,2 , Vassil Sgurev1 , Venelina and Metallurgy, 1756 Sofia Abstract: A new hybrid intelligent system is proposed for Heating, Ventilation and Air

  16. High-Temperature-High-Volume Lifting for Enhanced Geothermal...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems High-Temperature-High-Volume Lifting for...

  17. Leak testing plan for the Oak Ridge National Laboratory liquid low-level waste systems (active tanks): Revision 2. Volume 1: Regulatory background and plan approach; Volume 2: Methods, protocols, and schedules; Volume 3: Evaluation of the ORNL/LT-823DP differential pressure leak detection method; Appendix to Revision 2: DOE/EPA/TDEC correspondence

    SciTech Connect (OSTI)

    Douglas, D.G.; Wise, R.F.; Starr, J.W.; Maresca, J.W. Jr. [Vista Research, Inc., Mountain View, CA (United States)

    1994-11-01

    This document, the Leak Testing Plan for the Oak Ridge National Laboratory Liquid Low-Level Waste System (Active Tanks), comprises three volumes. The first two volumes address the component-based leak testing plan for the liquid low-level waste system at Oak Ridge, while the third volume describes the performance evaluation of the leak detection method that will be used to test this system. Volume 1, describes that portion of the liquid low-level waste system at that will be tested; it provides the regulatory background, especially in terms of the requirements stipulated in the Federal Facilities Agreement, upon which the leak testing plan is based. Volume 1 also describes the foundation of the plan, portions of which were abstracted from existing federal documents that regulate the petroleum and hazardous chemicals industries. Finally, Volume 1 gives an overview the plan, describing the methods that will be used to test the four classes of components in the liquid low-level waste system. Volume 2 takes the general information on component classes and leak detection methods presented in Volume 1 and shows how it applies particularly to each of the individual components. A complete test plan for each of the components is presented, with emphasis placed on the methods designated for testing tanks. The protocol for testing tank systems is described, and general leak testing schedules are presented. Volume 3 describes the results of a performance evaluation completed for the leak testing method that will be used to test the small tanks at the facility (those less than 3,000 gal in capacity). Some of the details described in Volumes 1 and 2 are expected to change as additional information is obtained, as the viability of candidate release detection methods is proven in the Oak Ridge environment, and as the testing program evolves.

  18. Final Report: Mobile Surveillance and Wireless Communication Systems Field Operational Test; Volume 1: Executive Summary

    E-Print Network [OSTI]

    Klein, Lawrence

    1999-01-01

    and Wireless Communication Systems Field Operational Testand Wireless Communication Systems Field Operational Testand Wireless Communication Systems Field Operational Test;

  19. Inverted Attic Bulkhead for HVAC Ductwork, Roseville, California (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-10-01

    K. Hovnanian Homes constructed a 2,253-ft single-story slab-on-grade ranch house for an occupied test house (new construction) in Roseville, California. One year of monitoring and analysis focused on the effectiveness of the space conditioning system at maintaining acceptable temperature and relative humidity levels in several rooms of the home, as well as room-to-room differences and the actual measured energy consumption by the space conditioning system. In this home, the air handler unit (AHU) and ducts were relocated to inside the thermal boundary. The AHU was relocated from the attic to a mechanical closet, and the ductwork was located inside an insulated and air-sealed bulkhead in the attic. To describe the performance and comfort in the home, the research team selected representative design days and extreme days from the annual data for analysis. To ensure that temperature differences were within reasonable occupant expectations, the team followed Air Conditioning Contractors of America guidance. At the end of the monitoring period, the occupant of the home had no comfort complaints in the home. Any variance between the modeled heating and cooling energy and the actual amounts used can be attributed to the variance in temperatures at the thermostat versus the modeled inputs.

  20. Commercial HVAC and Water-Heating Equipment Minimum Efficiency Standards in the United States

    SciTech Connect (OSTI)

    Nasseri, Cyrus H.; Somasundaram, Sriram

    2001-08-01

    ABSTRACT In 1992, Federal legislation mandated that the U.S. Department of Energy (DOE) set the efficiency levels in the then-current ASHRAE Standard 90.1 as mandatory minimums for heating, ventilating, and air-conditioning (HVAC) and service water-heating (SWH) equipment sold in the U.S. market, as well as a process for revising the minimum equipment efficiency standards to comply with requirements in an updated Standard 90.1. Because Standard 90.1 was updated in October 1999 (Standard 90.1-1999), DOE is now undertaking a rulemaking process for these equipment categories. In January 2001, DOE published a final rule adopting Standard 90.1-1999 levels as uniform national standards for 18 product categories of commercial HVAC and SWH equipment. For 11 other categories of commercial products, DOE has signaled its intention to consider more stringent standards than those adopted by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE). DOE has now initiated a formal rulemaking process to further analyze these equipment categories.

  1. Communications of the Association for Information Systems | Number 1Volume 28 Article 22

    E-Print Network [OSTI]

    -1-2011 Information Security Risk Management: In Which Security Solutions Is It Worth Investing? Stefan Fenz Vienna, Thomas (2011) "Information Security Risk Management: In Which Security Solutions Is It Worth Investing://aisel.aisnet.org/cais/vol28/iss1/22 #12;Volume 28 Article 22 Information Security Risk Management: In Which Security Solutions

  2. Advanced system demonstration for utilization of biomass as an energy source. Volume IV. Design drawings

    SciTech Connect (OSTI)

    None

    1980-10-01

    This volume contains design drawings for the biomass cogeneration plant to be built in Maine. The drawings show a considerable degree of detail, however, they are not to be considered released for construction. There has been no actual procurement of equipment, therefore equipment drawings certified by suppliers have not been included. (DMC)

  3. Third order nite volume evolution Galerkin (FVEG) methods for two-dimensional wave equation system

    E-Print Network [OSTI]

    Galerkin schemes, recovery stage, #12;nite volume. 1 Introduction Evolution Galerkin methods (EG and Warnecke constructed further EG-schemes, namely EG1, EG2 and EG3. In [14] Zahaykah derived the approximate these results new 2D EG schemes, namely FREG, SREG and EG4 schemes were de- rived, cf. [14]. These methods were

  4. Control Humidity With Single-Duct, Single-Zone, Constant Air Volume System 

    E-Print Network [OSTI]

    Chen, H.; Deng, S.; Bruner, H. L.; Claridge, D. E.

    2000-01-01

    The lecture hall of the Richardson Petroleum Building at Texas A&M University is a large lecture hall, with a total floor area of approximately 2500 ft^2. The lecture hall was served by a constant air volume (CAV) air handling unit (AHU) which had...

  5. APS-5: 5th international symposium on automotive propulsion systems. Volume 2

    SciTech Connect (OSTI)

    1980-10-01

    Thirty papers presented at the meeting are included in this volume. A separate abstract was prepared for each of 28 papers. Two papers were previously processed for the Energy Data Base. Abstracts for individual papers were not prepared for Energy Abstracts for Policy Analysis (EAPA). (LCL)

  6. Dynamic Modeling and Cascaded Control for a Multi-Evaporator Supermarket Refrigeration System 

    E-Print Network [OSTI]

    Gupta, Ankush 1986-

    2012-09-27

    The survey from US Department of Energy showed that about one-third of energy consumption in US is due to air conditioning and refrigeration systems. This significant usage of electricity in the HVAC industry has prompted researchers to develop...

  7. Application of real time transient temperature (RT{sup 3}) program on nuclear power plant HVAC analysis

    SciTech Connect (OSTI)

    Cai, Y.; Tomlins, V.A.; Haskell, N.L.; Giffels, F.W.

    1996-08-01

    A database oriented technical analysis program (RT) utilizing a lumped parameter model combined with a finite difference method was developed to concurrently simulate transient temperatures in single or multiple room(s)/area(s). Analyses can be seen for postulated design basis events, such as, 10CFR50 Appendix-R, Loss of Coolant Accident concurrent with Loss of Offsite Power (LOCA/LOOP), Station BlackOut (SBO), and normal station operating conditions. The rate of change of the air temperatures is calculated by explicitly solving a series of energy balance equations with heat sources and sinks that have been described. For building elements with heat absorbing capacity, an explicit Forward Time Central Space (FTCS) model of one dimensional transient heat conduction in a plane element is used to describe the element temperature profile. Heat migration among the rooms/areas is considered not only by means of conduction but also by means of natural convection induced by temperature differences through openings between rooms/areas. The program also provides a means to evaluate existing plant HVAC system performance. The performance and temperature control of local coolers/heaters can be also simulated. The program was used to calculate transient temperature profiles for several buildings and rooms housing safety-related electrical components in PWR and BWR nuclear power plants. Results for a turbine building and reactor building in a BWR nuclear power plant are provided here. Specific calculational areas were defined on the basis of elevation, physical barriers and components/systems. Transient temperature profiles were then determined for the bounding design basis events with winter and summer outdoor air temperatures.

  8. 7/11/00-draft copy: do not quote 1 of 30 New Technologies for Residential HVAC Ducts

    E-Print Network [OSTI]

    7/11/00-draft copy: do not quote 1 of 30 New Technologies for Residential HVAC Ducts Burke Treidler, and are difficult to install in a manner which will insure no leaks. This report summarizes the potential for new technologies for ducts, duct fittings, and insulation. It begins with a review of what technology is currently

  9. Residential Forced Air System Cabinet Leakage and Blower Performance

    SciTech Connect (OSTI)

    Walker, Iain S.; Dickerhoff, Darryl J.; Delp, William W.

    2010-03-01

    This project evaluated the air leakage and electric power consumption of Residential HVAC components, with a particular focus on air leakage of furnace cabinets. Laboratory testing of HVAC components indicated that air leakage can be significant and highly variable from unit to unit ? indicating the need for a standard test method and specifying maximum allowable air leakage in California State energy codes. To further this effort, this project provided technical assistance for the development of a national standard for Residential HVAC equipment air leakage. This standard is being developed by ASHRAE and is called"ASHRAE Standard 193P - Method of test for Determining the Air Leakage Rate of HVAC Equipment". The final part of this project evaluated techniques for measurement of furnace blower power consumption. A draft test procedure for power consumption was developed in collaboration with the Canadian General Standards Board: CSA 823"Performance Standard for air handlers in residential space conditioning systems".

  10. Development of High-Efficiency Low-Lift Vapor Compression System - Final Report

    SciTech Connect (OSTI)

    Katipamula, Srinivas; Armstrong, Peter; Wang, Weimin; Fernandez, Nicholas; Cho, Heejin; Goetzler, W.; Burgos, J.; Radhakrishnan, R.; Ahlfeldt, C.

    2010-03-31

    PNNL, with cofunding from the Bonneville Power Administration (BPA) and Building Technologies Program, conducted a research and development activity targeted at addressing the energy efficiency goals targeted in the BPA roadmap. PNNL investigated an integrated heating, ventilation and air conditioning (HVAC) system option referred to as the low-lift cooling system that potentially offers an increase in HVAC energy performance relative to ASHRAE Standard 90.1-2004.

  11. Definition and means of maintaining the ventilation system confinement portion of the PFP safety envelope

    SciTech Connect (OSTI)

    Dick, J.D.; Grover, G.A.; O`Brien, P.M., Fluor Daniel Hanford

    1997-03-05

    The Plutonium Finishing Plant Heating Ventilation and Cooling system provides for the confinement of radioactive releases to the environment and provides for the confinement of radioactive contamination within designated zones inside the facility. This document identifies the components and procedures necessary to ensure the HVAC system provides these functions. Appendices E through J provide a snapshot of non-safety class HVAC equipment and need not be updated when the remainder of the document and Appendices A through D are updated.

  12. Home Energy Article: A Systems Approach to Retrofitting Residential HVAC Systems

    E-Print Network [OSTI]

    McWilliams, Jennifer A.; Walker, Iain S.

    2005-01-01

    s (LBNL) Home Energy Saver (http://homeenergysaver.lbl.gov),to DOE’s Home Energy Saver ( www.homenergysaver.lbl.gov )

  13. Economic evaluation of the annual cycle energy system (ACES). Final report. Volume III, appendices

    SciTech Connect (OSTI)

    Not Available

    1980-06-01

    This volume consists of seven appendices related to ACES, the first three of which are concerned with computer programs. The appendices are entitled: (A) ACESIM: Residential Program Listing; (B) Typical Inputs and Outputs of ACESIM; (C) CACESS: Commercial Building Program Listing; (D) Typical Weather-Year Selection Requirements; (E) Building Characteristics; (F) List of Major Variables Used in the Computer Programs; and (G) Bibliography. 79 references.

  14. IEA Wind Task 24 Integration of Wind and Hydropower Systems; Volume 2: Participant Case Studies

    SciTech Connect (OSTI)

    Acker, T.

    2011-12-01

    This report describes the background, concepts, issues and conclusions related to the feasibility of integrating wind and hydropower, as investigated by the members of IEA Wind Task 24. It is the result of a four-year effort involving seven IEA member countries and thirteen participating organizations. The companion report, Volume 2, describes in detail the study methodologies and participant case studies, and exists as a reference for this report.

  15. Proceedings of the coal-fired power systems 94: Advances in IGCC and PFBC review meeting. Volume 1

    SciTech Connect (OSTI)

    McDaniel, H.M.; Staubly, R.K.; Venkataraman, V.K. [eds.

    1994-06-01

    The Coal-Fired Power Systems 94 -- Advances in IGCC and PFBC Review Meeting was held June 21--23, 1994, at the Morgantown Energy Center (METC) in Morgantown, West Virginia. This Meeting was sponsored and hosted by METC, the Office of Fossil Energy, and the US Department of Energy (DOE). METC annually sponsors this conference for energy executives, engineers, scientists, and other interested parties to review the results of research and development projects; to discuss the status of advanced coal-fired power systems and future plans with the industrial contractors; and to discuss cooperative industrial-government research opportunities with METC`s in-house engineers and scientists. Presentations included industrial contractor and METC in-house technology developments related to the production of power via coal-fired Integrated Gasification Combined Cycle (IGCC) and Pressurized Fluidized Bed Combustion (PFBC) systems, the summary status of clean coal technologies, and developments and advancements in advanced technology subsystems, such as hot gas cleanup. A keynote speaker and other representatives from the electric power industry also gave their assessment of advanced power systems. This meeting contained 11 formal sessions and one poster session, and included 52 presentations and 24 poster presentations. Volume I contains papers presented at the following sessions: opening commentaries; changes in the market and technology drivers; advanced IGCC systems; advanced PFBC systems; advanced filter systems; desulfurization system; turbine systems; and poster session. Selected papers have been processed separately for inclusion in the Energy Science and Technology Database.

  16. CFD-based design of the ventilation system for the PHENIX detector

    SciTech Connect (OSTI)

    Parietti, L.; Martin, R.A.; Gregory, W.S.

    1996-10-01

    The three-dimensional flow and thermal fields surrounding the large PHENIX sub-atomic particle detector enclosed in the Major Facility Hall are simulated numerically in this study using the CFX finite volume, commercial, computer code. The predicted fields result from the interaction of an imposed downward ventilation system cooling flow and a buoyancy-driven thermal plume rising from the warm detector. An understanding of the thermal irregularities on the surface of the detector and in the flow surrounding is needed to assess the potential for adverse thermal expansion effects in detector subsystems, and to prevent ingestion of electronics cooling air from hot spots. With a computational model of the thermal fields on and surrounding the detector, HVAC engineers can evaluate and improve the ventilation system design prior to the start of construction. This paper summarizes modeling and results obtained for a conceptual MFH ventilation scheme.

  17. Feasibility of developing a portable driver performance data acquisition system for human factors research: Technical tasks. Volume 1

    SciTech Connect (OSTI)

    Carter, R.J.; Barickman, F.S.; Spelt, P.F.; Schmoyer, R.L.; Kirkpatrick, J.R.

    1998-01-01

    A two-phase, multi-year research program entitled ``development of a portable driver performance data acquisition system for human factors research`` was recently completed. The primary objective of the project was to develop a portable data acquisition system for crash avoidance research (DASCAR) that will allow drive performance data to be collected using a large variety of vehicle types and that would be capable of being installed on a given vehicle type within a relatively short-time frame. During phase 1 a feasibility study for designing and fabricating DASCAR was conducted. In phase 2 of the research DASCAR was actually developed and validated. This technical memorandum documents the results from the feasibility study. It is subdivided into three volumes. Volume one (this report) addresses the last five items in the phase 1 research and the first issue in the second phase of the project. Volumes two and three present the related appendices, and the design specifications developed for DASCAR respectively. The six tasks were oriented toward: identifying parameters and measures; identifying analysis tools and methods; identifying measurement techniques and state-of-the-art hardware and software; developing design requirements and specifications; determining the cost of one or more copies of the proposed data acquisition system; and designing a development plan and constructing DASCAR. This report also covers: the background to the program; the requirements for the project; micro camera testing; heat load calculations for the DASCAR instrumentation package in automobile trunks; phase 2 of the research; the DASCAR hardware and software delivered to the National Highway Traffic Safety Administration; and crash avoidance problems that can be addressed by DASCAR.

  18. Survey of strong motion earthquake effects on thermal power plants in California with emphasis on piping systems. Volume 2, Appendices

    SciTech Connect (OSTI)

    Stevenson, J.D.

    1995-11-01

    Volume 2 of the ``Survey of Strong Motion Earthquake Effects on Thermal Power Plants in California with Emphasis on Piping Systems`` contains Appendices which detail the detail design and seismic response of several power plants subjected to strong motion earthquakes. The particular plants considered include the Ormond Beach, Long Beach and Seal Beach, Burbank, El Centro, Glendale, Humboldt Bay, Kem Valley, Pasadena and Valley power plants. Included is a typical power plant piping specification and photographs of typical power plant piping specification and photographs of typical piping and support installations for the plants surveyed. Detailed piping support spacing data are also included.

  19. An evaluation of a prototype laboratory fume hood for use in a variable air volume, face velocity reducing system 

    E-Print Network [OSTI]

    Vickery, Cynthia Schoonmaker

    1992-01-01

    18000 Pressure Transmitter (Type 020), an EFT-5000-1 square rooting circuit, a PIC-1000 proportional integral controller, and a Honeywell E to P transducer. During the initial hood set-up phase, the Accu-Aire controls were connected to a sash sensor.... (Model GVT46015). Redd-i, Inc. Variable-Air-Volume Box (Model MV10, serial number 41511) Accu-Aire Systems, Inc. control panel with: MOD 18000 Pressure Transmitter (Type 020, serial number 9E10803), EFT-5000-1 square rooting circuit PIC-1000...

  20. Expert system for the design of heating, ventilating, and air-conditioning systems. Master's thesis

    SciTech Connect (OSTI)

    Camejo, P.J.

    1989-12-01

    Expert systems are computer programs that seek to mimic human reason. An expert system shelf, a software program commonly used for developing expert systems in a relatively short time, was used to develop a prototypical expert system for the design of heating, ventilating, and air-conditioning (HVAC) systems in buildings. Because HVAC design involves several related knowledge domains, developing an expert system for HVAC design requires the integration of several smaller expert systems known as knowledge bases. A menu program and several auxiliary programs for gathering data, completing calculations, printing project reports, and passing data between the knowledge bases are needed and have been developed to join the separate knowledge bases into one simple-to-use program unit.

  1. Fermilab D-0 Experimental Facility: Energy conservation report and mechanical systems design optimization and cost analysis study

    SciTech Connect (OSTI)

    Krstulovich, S.F.

    1987-10-31

    This report is developed as part of the Fermilab D-0 Experimental Facility Project Title II Design Documentation Update. As such, it concentrates primarily on HVAC mechanical systems design optimization and cost analysis.

  2. Energy Performance Evaluation and Development of Control Strategies for the Air-conditioning System of a Building at Construction Stage 

    E-Print Network [OSTI]

    Wang, S.; Xu, X.; Ma, Z.

    2006-01-01

    Energy consumption of HVAC systems in commercial buildings takes a great part of the total building energy consumption. Energy performance evaluation plays an important role in building energy efficiency improvement for existing buildings and new...

  3. HVAC Program

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration would likeUniverse (Journalvivo Low-Dose Lowď‚—34 Revision 0August 9, 2012 ISMscientists

  4. Distributed Energy Systems in California's Future: A Preliminary Report Volume 2

    E-Print Network [OSTI]

    Balderston, F.

    2010-01-01

    advantage of passive solar systems. Moreover, in the case of community energyenergy systems are shown in Table IX-7. That solar systems have a large advantagesolar rights and at the same time to take advantage of energy

  5. Distributed Energy Systems in California's Future: A Preliminary Report Volume 2

    E-Print Network [OSTI]

    Balderston, F.

    2010-01-01

    1976. R.T. Tamblyn, " Thermal Storage: June 1977. A Sleepinga flatplate collector and thermal storage system. With thethe collector and thermal storage and its exchange systems

  6. Distributed Energy Systems in California's Future: A Preliminary Report Volume 2

    E-Print Network [OSTI]

    Balderston, F.

    2010-01-01

    of Environmental Impacts of Energy Supply SOME OBSERVATIONS~. ~r:hnologies of energy supply, except for IIsupplyingllwith these systems. The energy supply system is described in

  7. Distributed Energy Systems in California's Future: A Preliminary Report Volume 2

    E-Print Network [OSTI]

    Balderston, F.

    2010-01-01

    Wind Cogeneration and Solar Thermal Hydroelectric Powerbasic heat source is solar thermal. Such a system includes afrom solar heat is o These solar thermal systems provide low

  8. DISTRIBUTED ENERGY SYSTEMS IN CALIFORNIA'S FUTURE: A PRELIMINARY REPORT, VOLUME I

    E-Print Network [OSTI]

    Authors, Various

    2010-01-01

    of various distributed and renewable energy systems forto operate on renewable, largely distributed energy systems,distributed and largely renewable resources and from non-renewable energy

  9. Distributed Energy Systems in California's Future: A Preliminary Report Volume 2

    E-Print Network [OSTI]

    Balderston, F.

    2010-01-01

    of Some Major Energy Alternatives." Unpublishe d paper. (on Nuclear and Alternative Energy Systems (CONAES), FinalStudy of Nuclear and Alternative .Energy Systems, National

  10. Transportation Sector Model of the National Energy Modeling System. Volume 2 -- Appendices: Part 3

    SciTech Connect (OSTI)

    NONE

    1998-01-01

    This Appendix consists of two unpublished reports produced by Energy and Environmental Analysis, Inc., under contract to Oak Ridge National Laboratory. These two reports formed the basis for the subsequent development of the Fuel Economy Model described in Volume 1. They are included in order to document more completely the efforts undertaken to construct a comprehensive model of automobile fuel economy. The supplemental reports are as follows: Supplement 1--Documentation Attributes of Technologies to Improve Automotive Fuel Economy; Supplement 2--Analysis of the Fuel Economy Boundary for 2010 and Comparison to Prototypes.

  11. Distributed Energy Systems in California's Future: A Preliminary Report Volume 2

    E-Print Network [OSTI]

    Balderston, F.

    2010-01-01

    combined household greywater, human urine, and industrialwater system, the remaining greywater inflow could be reused

  12. Distributed Energy Systems in California's Future: A Preliminary Report Volume 2

    E-Print Network [OSTI]

    Balderston, F.

    2010-01-01

    systems. Alternative Energy Cooperative. Julie Reynolds,founder of Alternative Energy Cooperative), August 1, 1977,

  13. Study to assess the effects of magnetohydrodynamic electromagnetic pulse on electric power systems. Phase I, final report. Volume 3

    SciTech Connect (OSTI)

    Legro, J.R.; Abi-Samra, N.C.; Tesche, F.M.

    1985-05-01

    In addition to the initial transients designated as fast transient high-altitude EMP (HEMP) and intermediate time EMP, electromagnetic signals are also perceived at times from seconds to hundreds of seconds after a high-altitude nuclear burst. This signal has been defined by the term magnetohydrodynamic-electromagnetic pulse (MHD-EMP). The MHD-EMP phenomena has been both detected in actual weapon tests and predicted from theoretical models. This volume documents a preliminary research effort to investigate the nature and coupling of the MHD-EMP environments to electric power systems, define the construction of approximate system response network models, and document the development of a unified methodology to assess equipment and systematic vulnerability. The MHD-EMP environment is compared to a qualitatively similar natural event, the electromagnetic environment produced by geomagnetic storms.

  14. Market assessment for active solar heating and cooling products. Category B: a survey of decision-makers in the HVAC marketplace. Final report

    SciTech Connect (OSTI)

    1980-09-01

    A comprehensive evaluation of the market for solar heating and cooling products for new and retrofit markets is reported. The emphasis is on the analysis of solar knowledge among HVAC decision makers and a comprehensive evaluation of their solar attitudes and behavior. The data from each of the following sectors are described and analyzed: residential consumers, organizational and manufacturing buildings, HVAC engineers and architects, builders/developers, and commercial/institutional segments. (MHR)

  15. Distributed Energy Systems in California's Future: A Preliminary Report Volume 2

    E-Print Network [OSTI]

    Balderston, F.

    2010-01-01

    OF UTILIZING DISTRIBUTED ENERGY TECHNOLOGIES . . . . . . .DISTRIBUTED ENERGY SYSTEMS I~N CALIF RNIA/S FUTURE: UU-6831Ur'l1E:i\\i-fS SECTION DISTRIBUTED ENERGY SYSTEMS STUDY GROUP

  16. Distributed Energy Systems in California's Future: A Preliminary Report Volume 2

    E-Print Network [OSTI]

    Balderston, F.

    2010-01-01

    ENVIRONMENTAL IMPACTS OF ALTERNATIVE ENERGY TECHNOLOGIES FORENVIRONMENTAL IMPACTS OF ALTERNATIVE ENERGY TECHNOLOGIES FORon Nuclear and Alternative Energy Systems (CONAES), Final

  17. Hybrid Parallelism for Volume Rendering on Large, Multi- and Many-core Systems

    SciTech Connect (OSTI)

    Howison, Mark; Bethel, E. Wes; Childs, Hank

    2011-01-01

    With the computing industry trending towards multi- and many-core processors, we study how a standard visualization algorithm, ray-casting volume rendering, can benefit from a hybrid parallelism approach. Hybrid parallelism provides the best of both worlds: using distributed-memory parallelism across a large numbers of nodes increases available FLOPs and memory, while exploiting shared-memory parallelism among the cores within each node ensures that each node performs its portion of the larger calculation as efficiently as possible. We demonstrate results from weak and strong scaling studies, at levels of concurrency ranging up to 216,000, and with datasets as large as 12.2 trillion cells. The greatest benefit from hybrid parallelism lies in the communication portion of the algorithm, the dominant cost at higher levels of concurrency. We show that reducing the number of participants with a hybrid approach significantly improves performance.

  18. Arch-based configurations in the volume ensemble of static granular systems

    E-Print Network [OSTI]

    D. Slobinsky; Luis A. Pugnaloni

    2014-11-27

    We propose an alternative approach to count the microscopic static configurations of granular packs under gravity by considering arches. This strategy simplifies the problem of filtering out configurations that are not mechanically stable, opening the way for a range of granular models to be studied via ensemble theory. Following this arch-based approach, we have obtained the exact density of states for a two-dimensional non-interacting rigid arch model of granular assemblies. The calculated arch size distribution and volume fluctuations show qualitative agreement with realistic simulations of tapped granular beds. We have also validated our calculations by comparing with the analytic solution for the limiting case of a quasi-one-dimensional column of frictionless disks.

  19. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Functional modules F9--F16 -- Volume 2, Part 2, Revision 4

    SciTech Connect (OSTI)

    West, J.T.; Hoffman, T.J.; Emmett, M.B.; Childs, K.W.; Petrie, L.M.; Landers, N.F.; Bryan, C.B.; Giles, G.E.

    1995-04-01

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. The manual is divided into three volumes: Volume 1--for the control module documentation, Volume 2--for functional module documentation; and Volume 3--for documentation of the data libraries and subroutine libraries. This volume discusses the following functional modules: MORSE-SGC; HEATING 7.2; KENO V.a; JUNEBUG-II; HEATPLOT-S; REGPLOT 6; PLORIGEN; and OCULAR.

  20. 2013 TCEQ Annual Report Volume I. Energy Systems Laboratory, Texas A&M University 

    E-Print Network [OSTI]

    Haberl, J.S.; Yazdani, b; Baltazar, J. C.; Do, S. L.; Ellis, S.; Mukhopadhyay, J.; Parker, P.; Degelman, L.; Zilbertshtein, G.; Claridge, D.

    2014-01-01

    Estimates) All ERCOT ESL-Single Family ESL-Multifamily ESL-Commercial PUC (SB7) SECO Wind-ERCOT SEER13-Single Family SEER13-Multi Family 2013 TERP Report, Vol. I, p. 5 November 2014 Energy Systems Laboratory, The Texas A&M University System... .......................................................................................... 154 2013 TERP Report, Vol. I, p. 13 November 2014 Energy Systems Laboratory, The Texas A&M University System 1 Overview The Energy Systems Laboratory (Laboratory), at the Texas Engineering Experiment Station of the Texas A...

  1. Power-efficient hydraulic systems. Volume 1. Study phase. Final report, October 1985-July 1988

    SciTech Connect (OSTI)

    Hupp, R.V.; Haning, R.K.

    1988-07-01

    Energy-saving concepts for aircraft hydraulic systems were studied in a two-phase program. Task I was an investigation of methods and techniques to reduce overall hydraulic-system power requirements by lowering system demands and increasing component efficiencies. Task II involved hardware demonstration test on selected concepts. Task I: Study Phase. A baseline hydraulic system for an advanced aircraft design was established. Twenty energy-saving techniques were studied as candidates for application to the baseline vehicle. A global systems-analysis approach was employed. The candidates were compared on the basis of total fuel consumption and six qualitative factors. Nine of the most-promising techniques were applied to a Target System . The target system had a 28% reduction in energy consumption and an 868 lb weight reduction over the baseline aircraft.

  2. HVDC-AC system interaction from AC harmonics. Volume 1. Harmonic impedance calculations. Final report

    SciTech Connect (OSTI)

    Breuer, G D; Chow, J H; Lindh, C B; Miller, N W; Numrich, F H; Price, W W; Turner, A E; Whitney, R R

    1982-09-01

    Improved methods are needed to characterize ac system harmonic behavior for ac filter design for HVDC systems. The purpose of this General Electric Company RP1138 research is to evaluate the present filter design practice and to investigate methods for calculating system harmonic impedances. An overview of ac filter design for HVDC systems and a survey of literature related to filter design have been performed. Two methods for calculating system harmonic impedances have been investigated. In the measurement method, an instrumentation system for measuring system voltage and current has been assembled. Different schemes of using the measurements to calculate system harmonic impedances have been studied. In the analytical method, a procedure to include various operating conditions has been proposed. Computer programs for both methods have been prepared, and the results of the measurement and analytical methods analyzed. A conclusion of the project is that the measurement and analytical methods both provided reasonable results. There are correlations between the measured and analytical results for most harmonics, although there are discrepancies between the assumptions used in the two methods. A sensitivity approach has been proposed to further correlate the results. From the results of the analysis, it is recommended that both methods should be tested further. For the measurement method, more testing should be done to cover different system operating conditions. In the analytical method, more detailed models for representing system components should be studied. In addition, alternative statistical and sensitivity approaches should be attempted.

  3. Technical and economic assessment of fluidized bed augmented compressed air energy-storage system. Volume II. Introduction and technology assessment

    SciTech Connect (OSTI)

    Giramonti, A.J.; Lessard, R.D.; Merrick, D.; Hobson, M.J.

    1981-09-01

    The results are described of a study subcontracted by PNL to the United Technologies Research Center on the engineering feasibility and economics of a CAES concept which uses a coal fired, fluidized bed combustor (FBC) to heat the air being returned from storage during the power production cycle. By burning coal instead of fuel oil, the CAES/FBC concept can completely eliminate the dependence of compressed air energy storage on petroleum fuels. The results of this assessment effort are presented in three volumes. Volume II presents a discussion of program background and an in-depth coverage of both fluid bed combustion and turbomachinery technology pertinent to their application in a CAES power plant system. The CAES/FBC concept appears technically feasible and economically competitive with conventional CAES. However, significant advancement is required in FBC technology before serious commercial commitment to CAES/FBC can be realized. At present, other elements of DOE, industrial groups, and other countries are performing the required R and D for advancement of FBC technology. The CAES/FBC will be reevaluated at a later date when FBC technology has matured and many of the concerns now plaguing FBC are resolved. (LCL)

  4. Guidelines for the verification and validation of expert system software and conventional software: Survey and documentation of expert system verification and validation methodologies. Volume 3

    SciTech Connect (OSTI)

    Groundwater, E.H.; Miller, L.A.; Mirsky, S.M.

    1995-03-01

    This report is the third volume in the final report for the Expert System Verification and Validation (V&V) project which was jointly sponsored by the Nuclear Regulatory Commission and the Electric Power Research Institute. The ultimate objective is the formulation of guidelines for the V&V of expert systems for use in nuclear power applications. The purpose of this activity was to survey and document techniques presently in use for expert system V&V. The survey effort included an extensive telephone interviewing program, site visits, and a thorough bibliographic search and compilation. The major finding was that V&V of expert systems is not nearly as established or prevalent as V&V of conventional software systems. When V&V was used for expert systems, it was almost always at the system validation stage after full implementation and integration usually employing the non-systematic dynamic method of {open_quotes}ad hoc testing.{close_quotes} There were few examples of employing V&V in the early phases of development and only weak sporadic mention of the possibilities in the literature. There is, however, a very active research area concerning the development of methods and tools to detect problems with, particularly, rule-based expert systems. Four such static-testing methods were identified which were not discovered in a comprehensive review of conventional V&V methods in an earlier task.

  5. SOLERAS - Solar Controlled Environment Agriculture Project. Final report, Volume 5. Science Applications, Incorporated system requirements definition

    SciTech Connect (OSTI)

    Not Available

    1985-01-01

    This report sets forth the system requirements for a Solar Controlled-Environment Agriculture System (SCEAS) Project. In the report a conceptual baseline system description for an engineering test facility is given. This baseline system employs a fluid roof/roof filter in combination with a large storage tank and a ground water heat exchanger in order to provide cooling and heating as needed. Desalination is accomplished by pretreatment followed by reverse osmosis. Energy is provided by means of photovoltaics and wind machines in conjunction with storage batteries. Site and climatic data needed in the design process are given. System performance specifications and integrated system design criteria are set forth. Detailed subsystem design criteria are presented and appropriate references documented.

  6. Energy Management and Information Systems 

    E-Print Network [OSTI]

    Conraud, J.

    2013-01-01

    ?lb steam?/?year ? 2?power?distribution?networks 30MW?peak?demand ? 3?main?chilled?water?distribution? networks 12,000?ton?capacity ? ?1,000?HVAC?systems? P h o t o : ? F l i c k e r ? U s e r ? t r e p e l u h t t p...?of?Measures ? Review?HVAC?schedules to?realign?occupants??needs? and?optimal?operations ? Optimize?ventilation?and? temperature?set?points ? Enthalpy?control?of?fresh? air ? Peak?shaving steam?generation?and?peak? power the?project the?project the?project the...

  7. Radioisotope thermoelectric generator transportation system safety analysis report for packaging. Volumes 1 and 2

    SciTech Connect (OSTI)

    Ferrell, P.C.

    1996-04-18

    This SARP describes the RTG Transportation System Package, a Type B(U) packaging system that is used to transport an RTG or similar payload. The payload, which is included in this SARP, is a generic, enveloping payload that specifically encompasses the General Purpose Heat Source (GPHS) RTG payload. The package consists of two independent containment systems mounted on a shock isolation transport skid and transported within an exclusive-use trailer.

  8. Power-efficient hydraulic systems. Volume 2. Hardware demonstration phase. Final report, October 1985-July 1988

    SciTech Connect (OSTI)

    Hupp, R.V.; Haning, R.K.

    1988-07-01

    Energy-saving concepts for aircraft hydraulic systems were studied in a two-phase program. Task I was an investigation of methods and techniques to reduce overall hydraulic-system power requirements by lowering system demands and increasing component efficiencies. Task II involved hardware demonstration tests on selected concepts. Task I: Study phase. A baseline hydraulic system for an advanced aircraft design was established. Twenty energy-saving techniques were studied as candidates for application to the baseline vehicle. A global systems analysis approach was employed. The candidates were compared on the basis of total fuel consumption and six qualitative factors. Task II: Hardware demonstration phase. Two techniques demonstrated for energy savings were control valves with overlap and dual pressure-level systems. Tests were conducted on control valves, a servo actuator, dual pressure pumps, and a lightweight hydraulic system simulator. Valves with 0.002-in. overlap reduced system energy consumption 18% compared to using valves with zero lap. Operation at 4000 psi reduced system energy consumption 53% compared to operation at 8000 psi. Pressure-level switching was accomplished with excellent results.

  9. Distributed Energy Systems in California's Future: A Preliminary Report Volume 2

    E-Print Network [OSTI]

    Balderston, F.

    2010-01-01

    Most Desirable Passive Solar Design Active Solar Heat On-Energy Systems Passive solar design of buildings Solar waterof implementing passive solar design techniques on a large

  10. Distributed Energy Systems in California's Future: A Preliminary Report Volume 2

    E-Print Network [OSTI]

    Balderston, F.

    2010-01-01

    will production and consumption of solar energy for heatingsolar technologies and reduced energy consumption. Theconsumption must be reduced for alternative energy systems (eg. solar,

  11. DISTRIBUTED ENERGY SYSTEMS IN CALIFORNIA'S FUTURE: A PRELIMINARY REPORT, VOLUME I

    E-Print Network [OSTI]

    Authors, Various

    2010-01-01

    DOCU[viENTS SECTION DISTRIBUTED ENERGY SYSTEMS STUDY GROUPIMPLICATIONS OF UTILIZING DISTRIBUTED ENERGY TECHNOLOGIES .to implement a distributed energy future. RECENT TRENDS IN

  12. DISTRIBUTED ENERGY SYSTEMS IN CALIFORNIA'S FUTURE: A PRELIMINARY REPORT, VOLUME I

    E-Print Network [OSTI]

    Authors, Various

    2010-01-01

    and Solar Thermal Hydroelectric Power Geothermal . Land UsePower Commission, Hydroelectric Power Resources of thesome development for the hydroelectric power system. Nuclear

  13. DISTRIBUTED ENERGY SYSTEMS IN CALIFORNIA'S FUTURE: A PRELIMINARY REPORT, VOLUME I

    E-Print Network [OSTI]

    Authors, Various

    2010-01-01

    serves as the solar collector and storage (Anderson, 1977).with neighborhood solar collection The and storage, anduse active solar systems (collectors plus storage) to meet

  14. The integration of renewable energy sources into electric power distribution systems. Volume 2, Utility case assessments

    SciTech Connect (OSTI)

    Zaininger, H.W.; Ellis, P.R.; Schaefer, J.C.

    1994-06-01

    Electric utility distribution system impacts associated with the integration of renewable energy sources such as photovoltaics (PV) and wind turbines (WT) are considered in this project. The impacts are expected to vary from site to site according to the following characteristics: (1) The local solar insolation and/or wind characteristics; (2) renewable energy source penetration level; (3) whether battery or other energy storage systems are applied; and (4) local utility distribution design standards and planning practices. Small, distributed renewable energy sources are connected to the utility distribution system like other, similar kW- and MW-scale equipment and loads. Residential applications are expected to be connected to single-phase 120/240-V secondaries. Larger kw-scale applications may be connected to three-phase secondaries, and larger hundred-kW and MW-scale applications, such as MW-scale windfarms or PV plants, may be connected to electric utility primary systems via customer-owned primary and secondary collection systems. Small, distributed renewable energy sources installed on utility distribution systems will also produce nonsite-specific utility generation system benefits such as energy and capacity displacement benefits, in addition to the local site-specific distribution system benefits. Although generation system benefits are not site-specific, they are utility-specific, and they vary significantly among utilities in different regions. In addition, transmission system benefits, environmental benefits and other benefits may apply. These benefits also vary significantly among utilities and regions. Seven utility case studies considering PV, WT, and battery storage were conducted to identify a range of potential renewable energy source distribution system applications.

  15. Proceedings of the coal-fired power systems 94: Advances in IGCC and PFBC review meeting. Volume 2

    SciTech Connect (OSTI)

    McDaniel, H.M.; Staubly, R.K.; Venkataraman, V.K.

    1994-06-01

    The Coal-Fired Power Systems 94 -- Advances in IGCC and PFBC Review Meeting was held June 21--23, 1994, at the Morgantown Energy Center (METC) in Morgantown, West Virginia. This Meeting was sponsored and hosted by METC, the Office of Fossil Energy, and the US Department of Energy (DOE). METC annually sponsors this conference for energy executives, engineers, scientists, and other interested parties to review the results of research and development projects; to discuss the status of advanced coal-fired power systems and future plans with the industrial contractors; and to discuss cooperative industrial-government research opportunities with METC`s in-house engineers and scientists. Presentations included industrial contractor and METC in-house technology developments related to the production of power via coal-fired Integrated Gasification Combined Cycle (IGCC) and Pressurized Fluidized Bed Combustion (PFBC) systems, the summary status of clean coal technologies, and developments and advancements in advanced technology subsystems, such as hot gas cleanup. A keynote speaker and other representatives from the electric power industry also gave their assessment of advanced power systems. This meeting contained 11 formal sessions and one poster session, and included 52 presentations and 24 poster presentations. Volume II contains papers presented at the following sessions: filter technology issues; hazardous air pollutants; sorbents and solid wastes; and membranes. Selected papers have been processed separately for inclusion in the Energy Science and Technology Database.

  16. Solar Central Receiver Hybrid Power Systems sodium-cooled receiver concept. Final report. Volume I. Executive summary

    SciTech Connect (OSTI)

    None

    1980-01-01

    The overall, long-term objective of the Solar Central Receiver Hybrid Power System program is to identify, characterize, and ultimately demonstrate the viability and cost effectiveness of solar/fossil, steam Rankine cycle, hybrid power systems that: (1) consist of a combined solar central receiver energy source and a nonsolar energy source at a single, common site, (2) may operate in the base, intermediate, and peaking capacity modes, (3) produce the rated output independent of variations in solar insolation, (4) provide a significant savings (50% or more) in fuel consumption, and (5) produce power at the minimum possible cost in mills/kWh. It is essential that these hybrid concepts be technically feasible and economically competitive with other systems in the near to mid-term time period (1985-1990) on a commercial scale. The program objective for Phase I is to identify and conceptually characterize solar/fossil steam Rankine cycle, commercial-scale, power plant systems that are economically viable and technically feasible. A summary of results of Phase I is given in this volume. (WHK)

  17. SPEAR-BETA fuel performance code system. Volume 1. General description. Final report. [BWR; PWR

    SciTech Connect (OSTI)

    Christensen, R.

    1982-04-01

    This document provides a general description of the SPEAR-BETA fuel reliability code system. Included is a discussion of the methodology employed and the structure of the code system, as well as discussion of the major components: the data preparation routines, the mechanistic fuel performance model, the mechanistic cladding failure model, and the statistical failure model.

  18. Excluded-volume interactions and structure formation in thin layers of bent-core systems

    E-Print Network [OSTI]

    Lech Longa; Pawe? Karbowniczek; Micha? Cie?la; Agnieszka Chrzanowska

    2015-10-14

    Two-dimensional assemblies of bent-core shaped molecules attain at highly orienting surfaces liquid crystalline structures characteristic mostly for lamellar chiral or nonchiral antiferroelectric order [J. Phys. Chem. B {\\bf 109}, 18733 (2005)]. Here, using the Onsager-type of density functional theory we investigate the role of excluded-volume interactions in stabilizing different structures in thin films filled with bent-shaped molecules. We study influence of molecular features, like the apex angle, thickness of the arm and the type of the arm edges on the stability of layered structures. For molecular shapes taken the observed phases are dominated by the lamellar antiferroelectric type as observed experimentally, but a considerable sensitivity of the ordering to details of the molecular shape is also found for high packing fractions. In particular, smectic A, ferroelectric smectic A and ferroelectric nematic phases are foreseen from the bifurcation analysis in this limit. The presented theory models equilibrium properties of bent-core liquid crystals subjected to strong planar anchoring, \\emph{i.e.} in the case when details of the surface are of secondary importance.

  19. Nuclear Engine System Simulation (NESS). Volume 1: Program user's guide. Final Report

    SciTech Connect (OSTI)

    Pelaccio, D.G.; Scheil, C.M.; Petrosky, L.J.

    1993-03-01

    A Nuclear Thermal Propulsion (NTP) engine system design analysis tool is required to support current and future Space Exploration Initiative (SEI) propulsion and vehicle design studies. Currently available NTP engine design models are those developed during the NERVA program in the 1960's and early 1970's and are highly unique to that design or are modifications of current liquid propulsion system design models. To date, NTP engine-based liquid design models lack integrated design of key NTP engine design features in the areas of reactor, shielding, multi-propellant capability, and multi-redundant pump feed fuel systems. Additionally, since the SEI effort is in the initial development stage, a robust, verified NTP analysis design tool could be of great use to the community. This effort developed an NTP engine system design analysis program (tool), known as the Nuclear Engine System Simulation (NESS) program, to support ongoing and future engine system and stage design study efforts. In this effort, Science Applications International Corporation's (SAIC) NTP version of the Expanded Liquid Engine Simulation (ELES) program was modified extensively to include Westinghouse Electric Corporation's near-term solid-core reactor design model. The ELES program has extensive capability to conduct preliminary system design analysis of liquid rocket systems and vehicles. The program is modular in nature and is versatile in terms of modeling state-of-the-art component and system options as discussed. The Westinghouse reactor design model, which was integrated in the NESS program, is based on the near-term solid-core ENABLER NTP reactor design concept. This program is now capable of accurately modeling (characterizing) a complete near-term solid-core NTP engine system in great detail, for a number of design options, in an efficient manner.

  20. Compliance problems of small utility systems with the Powerplant and Industrial Fuel Use Act of 1978: volume II - appendices

    SciTech Connect (OSTI)

    1981-01-01

    A study of the problems of compliance with the Powerplant and Industrial Fuel Use Act of 1978 experienced by electric utility systems which have a total generating capacity of less than 2000 MW is presented. This volume presents the following appendices: (A) case studies (Farmington, New Mexico; Lamar, Colorado; Dover, Delaware; Wolverine Electric Cooperative, Michigan; Central Telephone and Utilities, Kansas; Sierra Pacific Power Company, Nevada; Vero Beach, Florida; Lubbock, Texas; Western Farmers Cooperative, Oklahoma; and West Texas Utilities Company, Texas); (B) contacts and responses to study; (C) joint action legislation chart; (D) Texas Municipal Power Agency case study; (E) existing generating units jointly owned with small utilities; (F) future generating units jointly owned with small utilities; (G) Federal Register Notice of April 17, 1980, and letter of inquiry to utilities; (H) small utility responses; and (I) Section 744, PIFUA. (WHK)

  1. ''Rancho Hydro'': a low-head, high volume residential hydroelectric power system, Anahola, Kauai, Hawaii

    SciTech Connect (OSTI)

    Harder, J.D.

    1982-07-01

    The site is a 1.75 acre residential site with two households. The Anahola stream intersects the property line. Design of the proposed hydroelectric system is described, along with the permit process. Construction is in progress. (DLC)

  2. DISTRIBUTED ENERGY SYSTEMS IN CALIFORNIA'S FUTURE: A PRELIMINARY REPORT, VOLUME I

    E-Print Network [OSTI]

    Authors, Various

    2010-01-01

    a certain amount of energy: useful energy. 0.1 quad (Note that 0.1 quad of useful energy from a solar system Theto provide a unit of useful energy can be extended to the

  3. Distributed Energy Systems in California's Future: A Preliminary Report Volume 2

    E-Print Network [OSTI]

    Balderston, F.

    2010-01-01

    Electricity CMMBtu) of useful energy. Because many costs areis actually $2.62/MMBtu of useful energy. at four cents per5 to 10 percent of the useful energy delivered by the system

  4. Distributed Energy Systems in California's Future: A Preliminary Report Volume 2

    E-Print Network [OSTI]

    Balderston, F.

    2010-01-01

    in the thermal mass of a passive building. for degree dayEnergy Systems Passive solar design of buildings Solar waterPassive Solar Architecture and the California Building Code,

  5. Transportation Sector Model of the National Energy Modeling System. Volume 2 -- Appendices: Part 2

    SciTech Connect (OSTI)

    1998-01-01

    The attachments contained within this appendix provide additional details about the model development and estimation process which do not easily lend themselves to incorporation in the main body of the model documentation report. The information provided in these attachments is not integral to the understanding of the model`s operation, but provides the reader with opportunity to gain a deeper understanding of some of the model`s underlying assumptions. There will be a slight degree of replication of materials found elsewhere in the documentation, made unavoidable by the dictates of internal consistency. Each attachment is associated with a specific component of the transportation model; the presentation follows the same sequence of modules employed in Volume 1. The following attachments are contained in Appendix F: Fuel Economy Model (FEM)--provides a discussion of the FEM vehicle demand and performance by size class models; Alternative Fuel Vehicle (AFV) Model--describes data input sources and extrapolation methodologies; Light-Duty Vehicle (LDV) Stock Model--discusses the fuel economy gap estimation methodology; Light Duty Vehicle Fleet Model--presents the data development for business, utility, and government fleet vehicles; Light Commercial Truck Model--describes the stratification methodology and data sources employed in estimating the stock and performance of LCT`s; Air Travel Demand Model--presents the derivation of the demographic index, used to modify estimates of personal travel demand; and Airborne Emissions Model--describes the derivation of emissions factors used to associate transportation measures to levels of airborne emissions of several pollutants.

  6. Development of a Dispatchable PV Peak Shainv System. PV: Bonus Program - Phase 1 Report. Volume 1

    SciTech Connect (OSTI)

    1995-10-01

    This report summarizes the work performed by Delmarva Power and Light and its subcontractors in Phase 1 of the US Department of Energy's PV:BONUS Program. The purpose of the program is to develop products and systems for buildings which utilize photovoltaic (N) technology. Beginning with a cooperative research effort with the University of Delaware's Center for Energy and Environmental Policy Research Delmarva Power developed and demonstrated the concept of Dispatchable PV Peak Shaving. This concept and the system which resulted horn the development work are unique from other grid-connected PV systems because it combines a PV, battery energy storage, power conversion and control technologies into an integrated package. Phase 1 began in July 1993 with the installation of a test and demonstration system at Delmarva's Northern Division General Office building near Newark, Delaware. Following initial testing throughout the summer and fall of 1993, significant modifications were made under an amendment to the DOE contract. Work on Phase 1 concluded in the early spring of 1995. Significant progress towards the goal of commercializing the system was made during Phase 1, and is summarized. Based on progress in Phase 1, a proposal to continue the work in Phase 2 was submitted to the US DOE in May 1995. A contract amendment and providing funds for the Phase 2 work is expected in July 1995.

  7. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Functional modules F1--F8 -- Volume 2, Part 1, Revision 4

    SciTech Connect (OSTI)

    Greene, N.M.; Petrie, L.M.; Westfall, R.M.; Bucholz, J.A.; Hermann, O.W.; Fraley, S.K.

    1995-04-01

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. The manual is divided into three volumes: Volume 1--for the control module documentation; Volume 2--for functional module documentation; and Volume 3--for documentation of the data libraries and subroutine libraries.

  8. Building America Best Practices Series, Volume 6: High-Performance Home Technologies: Solar Thermal & Photovoltaic Systems

    SciTech Connect (OSTI)

    Baechler, Michael C.; Gilbride, Theresa L.; Ruiz, Kathleen A.; Steward, Heidi E.; Love, Pat M.

    2007-06-04

    This guide is was written by PNNL for the US Department of Energy's Building America program to provide information for residential production builders interested in building near zero energy homes. The guide provides indepth descriptions of various roof-top photovoltaic power generating systems for homes. The guide also provides extensive information on various designs of solar thermal water heating systems for homes. The guide also provides construction company owners and managers with an understanding of how solar technologies can be added to their homes in a way that is cost effective, practical, and marketable. Twelve case studies provide examples of production builders across the United States who are building energy-efficient homes with photovoltaic or solar water heating systems.

  9. Hanford Environmental Information System (HEIS). Volume 3, Subject Area reference manual

    SciTech Connect (OSTI)

    Schreck, R.I.

    1994-01-14

    The Hanford Environmental Information System (HEIS) Subject Area manuals are designed as reference guides, that is, each chapter provides the information needed to make best use of each subject area, its tables, and reporting capabilities. Each subject area is documented in a chapter in one of the subject area manuals. Because these are reference manuals, most of the information is also available in the online help system as well. See Section 5.4.2 of the HEIS User`s Guide (DOE-RL 1994a) for a detailed description of the online help.

  10. Bases for solid waste volume estimates for tank waste remediation system

    SciTech Connect (OSTI)

    Reddick, G.W., Westinghouse Hanford

    1996-08-01

    This document presents the background and basis for the Tank Waste Remediation System forecast for solid waste submitted in June 1996. The forecast was generated for single-shell tank and double-shell tank activities including operations through retrieval and disposal of chemical tank waste.

  11. Promoting high efficiency residential HVAC equipment: Lessons learned from leading utility programs

    SciTech Connect (OSTI)

    Neme, C.; Peters, J.; Rouleau, D.

    1998-07-01

    The Consortium for Energy Efficiency recently sponsored a study of leading electric utility efforts to promote high efficiency residential HVAC equipment. Given growing concerns from some utilities about the level of expenditures associated with rebate programs, special emphasis was placed on assessing the success of financing and other non-rebate options for promoting efficiency. Emphasis was also placed on review of efforts--rebate or otherwise--to push the market to very high levels of efficiency (i.e., SEER 13). This paper presents the results of the study. It includes discussion of key lessons from the utility programs analyzed. It also examines program participation rates and other potential indicators of market impacts. One notable conclusion is that several utility programs have pushed market shares for SEER 12 equipment to about 50% (the national average is less than 20%). At least one utility program has achieved a 50% market share for SEER 13 equipment (the national average is less than 3%). In general, financing does not appear to have as broad an appeal as consumer rebates. However, one unique utility program which combines the other of customer financing with modest incentives to contractors--in the form of frequent seller points that can be redeemed for advertising, technician training, travel and other merchandise--offers some promise that high participation rates can be achieved without customer rebates.

  12. Hanford Environmental Information System (HEIS) Operator`s Manual. Volume 1

    SciTech Connect (OSTI)

    Schreck, R.I.

    1991-10-01

    The Hanford Environmental Information System (HEIS) is a consolidated set of automated resources that effectively manage the data gathered during environmental monitoring and restoration of the Hanford Site. The HEIS includes an integrated database that provides consistent and current data to all users and promotes sharing of data by the entire user community. This manual describes the facilities available to the operational user who is responsible for data entry, processing, scheduling, reporting, and quality assurance. A companion manual, the HEIS User`s Manual, describes the facilities available-to the scientist, engineer, or manager who uses the system for environmental monitoring, assessment, and restoration planning; and to the regulator who is responsible for reviewing Hanford Site operations against regulatory requirements and guidelines.

  13. Desk study of production energy savings control systems feasibility study. (Russia). Volume 1. Export trade information

    SciTech Connect (OSTI)

    Not Available

    1992-07-17

    The objective of the feasibility study is to determine the marketability of heating/ventilating energy conserving control systems in the major city markets of eastern Russia. The second part of the objective is to determine if the existing military based Zelenograd micro-electronic manufacturing and research facility can be utilized to produce Direct Digital Control systems for use within Russia as well as for export to the European Economic Community (EEC) and other countries. Because significant exports of U.S. products and services to support the joint venture are questionable, it is suggested that, potential markets for U.S. products be identified. Sources of capital to finance the joint venture should be identified.

  14. Advanced coal-fueled gas turbine systems, Volume 1: Annual technical progress report

    SciTech Connect (OSTI)

    Not Available

    1988-07-01

    This is the first annual technical progress report for The Advanced Coal-Fueled Gas Turbine Systems Program. Two semi-annual technical progress reports were previously issued. This program was initially by the Department of Energy as an R D effort to establish the technology base for the commercial application of direct coal-fired gas turbines. The combustion system under consideration incorporates a modular three-stage slagging combustor concept. Fuel-rich conditions inhibit NO/sub x/ formation from fuel nitrogen in the first stage; coal ash and sulfur is subsequently removed from the combustion gases by an impact separator in the second stage. Final oxidation of the fuel-rich gases and dilution to achieve the desired turbine inlet conditions are accomplished in the third stage. 27 figs., 15 tabs.

  15. Reducing Building Energy Costs Using Optimized Operation Strategies for Constant Volume Air Handling Systems 

    E-Print Network [OSTI]

    Liu, M.; Athar, A.; Reddy, A.; Claridge, D. E.; Haberl, J. S.; White, E.

    1994-01-01

    , they involve resetting the cooling deck or heating deck temperature according to the ambient temperature such that maximum energy efficiency can be achieved without compromising indoor air quality and comfort. Extended O&M Measures optimize system..., building energy consumption can be further reduced even after these traditional O&M measures are applied. This involves optimal adjusting of cold deck and hot deck settings according to the ambient temperature and organizing cold deck settings properly...

  16. Operating experience feedback report -- turbine-generator overspeed protection systems: Commercial power reactors. Volume 11

    SciTech Connect (OSTI)

    Ornstein, H.L.

    1995-04-01

    This report presents the results of the US Nuclear Regulatory Commission`s Office for Analysis and Evaluation of Operational Data (AEOD) review of operating experience of main turbine-generator overspeed and overspeed protection systems. It includes an indepth examination of the turbine overspeed event which occurred on November 9, 1991, at the Salem Unit 2 Nuclear Power Plant. It also provides information concerning actions taken by other utilities and the turbine manufacturers as a result of the Salem overspeed event. AEOD`s study reviewed operating procedures and plant practices. It noted differences between turbine manufacturer designs and recommendations for operations, maintenance, and testing, and also identified significant variations in the manner that individual plants maintain and test their turbine overspeed protection systems. AEOD`s study provides insight into the shortcomings in the design, operation, maintenance, testing, and human factors associated with turbine overspeed protection systems. Operating experience indicates that the frequency of turbine overspeed events is higher than previously thought and that the bases for demonstrating compliance with NRC`s General Design Criterion (GDC) 4, Environmental and dynamic effects design bases, may be nonconservative with respect to the assumed frequency.

  17. 169 Australasian Journal of Information Systems Volume 13 Number 2 May 2006 ICT INTEGRITY: BRINGING THE ACS CODE OF ETHICS UP TO DATE

    E-Print Network [OSTI]

    De Montfort University

    Recognition of professionalism in information and communications technology (ICT) in Australia requires Weckert School of Information Studies, Center for Applied Philosophy and Public Ethics Charles Sturt169 Australasian Journal of Information Systems Volume 13 Number 2 May 2006 ICT INTEGRITY: BRINGING

  18. Lechowicz, M.J., 2001. Phenology. In the Encyclopedia of Global Environmental Change, Volume 2. The Earth System:biological and ecological dimensions of global environmental

    E-Print Network [OSTI]

    Lechowicz, Martin J.

    Lechowicz, M.J., 2001. Phenology. In the Encyclopedia of Global Environmental Change, Volume 2. The Earth System:biological and ecological dimensions of global environmental change. Wiley, London. Phenology Martin J. Lechowicz Department of Biology McGill University Montréal, Québec, CANADA Phenology

  19. Model documentation: Natural gas transmission and distribution model of the National Energy Modeling System. Volume 1

    SciTech Connect (OSTI)

    1995-02-17

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of integrated Analysis and Forecasting of the Energy information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The methodology employed allows the analysis of impacts of regional capacity constraints in the interstate natural gas pipeline network and the identification of pipeline capacity expansion requirements. There is an explicit representation of core and noncore markets for natural gas transmission and distribution services, and the key components of pipeline tariffs are represented in a pricing algorithm. Natural gas pricing and flow patterns are derived by obtaining a market equilibrium across the three main elements of the natural gas market: the supply element, the demand element, and the transmission and distribution network that links them. The NGTDM consists of four modules: the Annual Flow Module, the Capacity F-expansion Module, the Pipeline Tariff Module, and the Distributor Tariff Module. A model abstract is provided in Appendix A.

  20. Hanford Environmental Information System (HEIS). Volume 2, Operator`s guide

    SciTech Connect (OSTI)

    Not Available

    1994-01-14

    This report discusses the procedures that establish the configuration control processes for the Hanford Environmental Information System (HEIS) software. The procedures also provide the charter and function of the HEIS Configuration Control Board (CCB) for maintaining software. The software configuration control items covered under these procedures include the HEIS software and database structure. The configuration control processes include both administrative and audit functions. The administrative role includes maintaining the overall change schedule, ensuring consistency of proposed changes, negotiating change plan adjustments, setting priorities, and tracking the status of changes. The configuration control process audits to ensure that changes are performed to applicable standards.

  1. 2013 TCEQ Annual Report Volume II. Energy Systems Laboratory, Texas A&M University 

    E-Print Network [OSTI]

    Haberl, J.S.; Yazdani, B.; Baltazar, J. C.; Do, S. L.; Ellis, S.; Mukhopadhyay, J.; Parker, P.; Degelman, L.; Zilbertshtein, G.; Claridge, D.

    2014-01-01

    am also grateful to Dr. D. J, Hartfiel and Dr. L. J. Ringer, for serving as committee members TABLE OF CONTENTS Chapter Page I. BASIC NOTIONS OF MACHINES. Basic Definitions. Equivalence and Realizations Partitions and S. P. Partitions 1 8... properties: yh hh hh 1 tha hh 1 1 11 hh hyl 1 hh ~P11* of the American Mathematical ~gociet l. a finite set, X, of inputs such that any finite sequence of elements of X can be applied to the given digital system; 2. a finite set, S, of states which can...

  2. Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1

    SciTech Connect (OSTI)

    1998-01-01

    The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic design, provides detail on the methodology employed, and describes the model inputs, outputs, and key assumptions. Subsequent chapters of this report provide: an overview of NGTDM; a description of the interface between the NEMS and NGTDM; an overview of the solution methodology of the NGTDM; the solution methodology for the Annual Flow Module; the solution methodology for the Distributor Tariff Module; the solution methodology for the Capacity Expansion Module; the solution methodology for the Pipeline Tariff Module; and a description of model assumptions, inputs, and outputs.

  3. The Coastal Ocean Prediction Systems program: Understanding and managing our coastal ocean. Volume 1: Strategic summary

    SciTech Connect (OSTI)

    Not Available

    1990-05-15

    The proposed COPS (Coastal Ocean Prediction Systems) program is concerned with combining numerical models with observations (through data assimilation) to improve our predictive knowledge of the coastal ocean. It is oriented toward applied research and development and depends upon the continued pursuit of basic research in programs like COOP (Coastal Ocean Processes); i.e., to a significant degree it is involved with ``technology transfer`` from basic knowledge to operational and management applications. This predictive knowledge is intended to address a variety of societal problems: (1) ship routing, (2) trajectories for search and rescue operations, (3) oil spill trajectory simulations, (4) pollution assessments, (5) fisheries management guidance, (6) simulation of the coastal ocean`s response to climate variability, (7) calculation of sediment transport, (8) calculation of forces on structures, and so forth. The initial concern is with physical models and observations in order to provide a capability for the estimation of physical forces and transports in the coastal ocean. For all these applications, there are common needs for physical field estimates: waves, tides, currents, temperature, and salinity, including mixed layers, thermoclines, fronts, jets, etc. However, the intent is to work with biologists, chemists, and geologists in developing integrated multidisciplinary prediction systems as it becomes feasible to do so. From another perspective, by combining observations with models through data assimilation, a modern approach to monitoring is provided through whole-field estimation.

  4. Economic evaluation of the Annual Cycle Energy System (ACES). Volume II. Detailed results. Final report

    SciTech Connect (OSTI)

    Not Available

    1980-05-01

    The energy effectiveness and the economic viability of the ACES concept are examined. ACES is studied in a variety of different applications and compared to a number of conventional systems. The different applications are studied in two groups: the class of building into which the ACES is incorporated and the climatic region in which the ACES is located. Buildings investigated include single-family and multi-family residences and a commercial office building. The application of ACES to each of these building types is studied in Minneapolis, Atlanta, and Philadelphia. The economic evaluation of the ACES is based on a comparison of the present worth of the ACES to the present worth of conventional systems; namely, electric resistance heating, electric air conditioning, and electric domestic water heating; air-to-air heat pump and electric domestic water heating; oil-fired furnace, electric air conditioning, and electric domestic water heating; and gas-fired furnace, electric air conditioning, and gas domestic water heating.

  5. Progress toward Development of a High-Efficiency Zonal Thermoelectric HVAC System for Automotive Applications

    Broader source: Energy.gov [DOE]

    Presentation given at the 16th Directions in Engine-Efficiency and Emissions Research (DEER) Conference in Detroit, MI, September 27-30, 2010.

  6. Supervisory control for energy savings and thermal comfort in commercial building HVAC systems.

    E-Print Network [OSTI]

    Martin, Rodney A; Federspiel, Clifford C Ph.D.; Auslander, David M Ph.D.

    2002-01-01

    the goal of reduced energy and thermal comfort has been pro-treat the issues of energy, thermal comfort, and commercialControl for Energy Savings and Thermal Comfort in Commercial

  7. Model Predictive Control of HVAC Systems: Implementation and Testing at the University of California, Merced

    E-Print Network [OSTI]

    Haves, Phillip

    2010-01-01

    TOTAL ELECTRICAL AND THERMAL ENERGIES , AND CUMULATIVE COPtotal electrical and thermal energies, and  cumulative COP and parameter estimator  If thermal energy storage (TES) is 

  8. A Qualitive Modeling Approach for Fault Detection and Diagnosis on HVAC Systems 

    E-Print Network [OSTI]

    Muller, T.; Rehault, N.; Rist, T.

    2013-01-01

    Modelling Toolbox, Tutorial, Release 6.1. Ruhr-University Bochum, Fakult?t f?r Elektrotechnik und Informationstechnik. Lichtenberg, G. (2011). Methoden der modellbasierten Fehlerdiagnose. ModQS Workshop. Technische Universit?t Hamburg- Harburg...

  9. Whole-Building Commercial HVAC System Simulation for Use in Energy Consumption Fault Detection 

    E-Print Network [OSTI]

    Painter, Frank

    2007-01-01

    Consumption The calibrated simulation of step 2 is then run using the appropriate weather input data and other measured input data that may be available (e.g., internal electrical gains, return temperatures, etc.). The output of this simulation is corrected..., temperature and pressure sensors, and VSD speeds. One of the major factors that lead to selection of this building for study was the extensive utility metering that is present. Electricity consumption, cooling consumption, and heating consumption are all...

  10. Fight Fall Allergies and Save Energy by Checking Your HVAC System...

    Broader source: Energy.gov (indexed) [DOE]

    right? Oh, such navet. Three months into my stay, I developed a persistent, dry cough. After weeks of suffering, I realized that my heating unit was causing it. It was...

  11. Model Predictive Control of HVAC Systems: Implementation and Testing at the University of California, Merced

    E-Print Network [OSTI]

    Haves, Phillip

    2010-01-01

    motor speed  pump power [W]    volumetric flow rate [m 3 /i f f e volumetric flow [m /s] Figure 2.15: Pump model fit volumetric  flow?rate  and  ? p 0 is  the  nominal  pressure  across  the  pump.  

  12. Energy Efficient HVAC System for Distributed Cooling/Heating with Thermoelectric Devices

    Broader source: Energy.gov [DOE]

    2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

  13. Comparative guide to emerging diagnostic tools for large commercial HVAC systems

    E-Print Network [OSTI]

    Friedman, Hannah; Piette, Mary Ann

    2001-01-01

    Summer Study on Energy Efficiency in Buildings, WashingtonSummer Study on Energy Efficiency in Buildings, WashingtonSummer Study on Energy Efficiency in Buildings, Washington

  14. Co-design of Control Algorithm and Embedded Platformfor Building HVAC Systems

    E-Print Network [OSTI]

    Maasoumy, Mehdi; Zhu, Qi; Li, Cheng; Meggers, Forrest; Sangiovanni-Vincentelli, Alberto

    2013-01-01

    Fig. 5 show the energy cost and discomfort index of the sixdiscussion on energy cost and discomfort index, refer to [both en- ergy cost and discomfort index. For instance, the

  15. Remote Fault Detection of Building HVAC System Using a Global Optimization Program 

    E-Print Network [OSTI]

    Lee, S. U.; Claridge, D. E.

    2004-01-01

    117 of 120 faulty parameters in the presence of 10% noise. These results are based on acceptable errors for each parameter defined as ±5°F for Tcl, ±2°F for Tr, ±0.4cfm/sf for Vs, and ±5% for OA(%). If the acceptable errors for each parameter...

  16. Joint-Frequency Bins versus Conventional Bin Weather Data in Analysis of HVAC System Operation 

    E-Print Network [OSTI]

    Jones, A.; Baltazar, J. C.; Claridge, D. E.

    2009-01-01

    Often in simplified energy analysis the use of bin weather data is employed for a more time efficient and better organized analysis than using the full 8760-hour annual weather data. It has been suggested that joint-frequency bins be used instead...

  17. An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings

    E-Print Network [OSTI]

    Trcka, Marija

    2010-01-01

    DELIGHT2 daylighting analysis in EnergyPlus: Integration andflow model with the EnergyPlus Building Energy Simulationsuch tools include eQuest, EnergyPlus, DOE 2.1, IES VE, and

  18. Analysis of a hybrid UFAD and radiant hydronic slab HVAC system

    E-Print Network [OSTI]

    Raftery, Paul; Lee, Kwang Ho; Webster, Thomas; Bauman, Fred

    2011-01-01

    Validation of the EnergyPlus Low-Temperature Radiantviewsede/ DOE, “EnergyPlus: Building Technologies Program,”apps1.eere.energy.gov/buildings/energyplus/ DOE, “EnergyPlus

  19. Discussion of an Optimization Scheme for the Ground Source Heat Pump System of HVAC 

    E-Print Network [OSTI]

    Mu, W.; Wang, S.; Pan, S.; Shi, Y.

    2006-01-01

    With the implementation of the global sustainable development strategy, people pay more attention to renewable energy resources such as ground source heat pumps. The technology of ground source heat pump is widely applied to heat and cold...

  20. Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable-Speed-Drive Chillers

    E-Print Network [OSTI]

    facilities. At part-load conditions, the pumps and heat rejection device often operated at constant speed-Speed-Drive Chillers Tengfang Xu June 15, 2005 The project is funded by the California Energy Commission's Industrial of individual components and subsystems in the plant. Major components include chillers, water pumps