Sample records for hvac systems simulation

  1. MAPPING HVAC SYSTEMS FOR SIMULATION IN ENERGYPLUS

    E-Print Network [OSTI]

    Basarkar, Mangesh

    2013-01-01T23:59:59.000Z

    LBNL-XXXXX MAPPING HVAC SYSTEMS FOR SIMULATION IN ENERGYPLUSof California. MAPPING HVAC SYSTEMS FOR SIMULATION INpresent a conventional view of HVAC systems to the user, and

  2. SIMULATION OF RESIDENTIAL HVAC SYSTEM PERFORMANCE

    E-Print Network [OSTI]

    1 LBNL-47622 SIMULATION OF RESIDENTIAL HVAC SYSTEM PERFORMANCE Walker, I., Siegel, J ..................................................... 9 #12;3 ABSTRACT In many parts of North America residential HVAC systems are installed outside of the simulations is that they are dynamic - which accounts for cyclic losses from the HVAC system and the effect

  3. Co-simulation of innovative integrated HVAC systems in buildings

    E-Print Network [OSTI]

    Trcka, Marija

    2010-01-01T23:59:59.000Z

    Integrated Simulation for HVAC Per- formance Prediction:air-conditioning equipment models (HVAC BESTEST), volume 1:air-conditioning equipment models (HVAC BESTEST), volume 2:

  4. Co-simulation for performance prediction of integrated building and HVAC systems - An analysis of solution characteristics using a two-body system

    E-Print Network [OSTI]

    Trcka, Marija

    2010-01-01T23:59:59.000Z

    of innovative integrated HVAC systems in buildings, infor building envelope and HVAC systems simu- lation - WillIntegrated simulation for HVAC performance prediction: State

  5. Performance Validation and Energy Analysis of HVAC Systems using Simulation

    E-Print Network [OSTI]

    Diamond, Richard

    monitored system outputs for performance validation and energy analysis. The paper presents results from1 Performance Validation and Energy Analysis of HVAC Systems using Simulation Tim Salsbury and Rick Francisco. 1 Introduction Significant potential exists with the current technology of energy management

  6. Co-simulation for performance prediction of integrated building and HVAC systems -An analysis of solution

    E-Print Network [OSTI]

    performance simulation of buildings and heating, ventilation and air- conditioning (HVAC) systems can help, heating, ventilation and air-conditioning (HVAC) systems are responsible for 10%-60% of the total building

  7. Comparison of Building Energy Modeling Programs: HVAC Systems

    E-Print Network [OSTI]

    Zhou, Xin

    2014-01-01T23:59:59.000Z

    and Mehry Yazdanian. Comparisons of HVAC Simulations betweeninformation Comparison of HVAC System Simulations inCLT (kW) Comparison of HVAC System Simulations in Different

  8. Co-simulation of innovative integrated HVAC systems in buildings

    SciTech Connect (OSTI)

    Trcka, Marija; Hensena, Jan L.M.; Wetter, Michael

    2010-06-21T23:59:59.000Z

    Integrated performance simulation of buildings HVAC systems can help in reducing energy consumption and increasing occupant comfort. However, no single building performance simulation (BPS) tool offers sufficient capabilities and flexibilities to analyze integrated building systems and to enable rapid prototyping of innovative building and system technologies. One way to alleviate this problem is to use co-simulation, as an integrated approach to simulation. This article elaborates on issues important for co-simulation realization and discusses multiple possibilities to justify the particular approach implemented in the here described co-simulation prototype. The prototype is validated with the results obtained from the traditional simulation approach. It is further used in a proof-of-concept case study to demonstrate the applicability of the method and to highlight its benefits. Stability and accuracy of different coupling strategies are analyzed to give a guideline for the required coupling time step.

  9. An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings

    E-Print Network [OSTI]

    Trcka, Marija

    2010-01-01T23:59:59.000Z

    and Judkoff, R. 2002. IEA HVAC BESTEST volume 1, Technicaland Judkoff, R. 2004. IEA HVAC BESTEST volume 2, TechnicalOF INNOVATIVE INTEGRATED HVAC SYSTEMS IN BUILDINGS Marija

  10. Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues

    E-Print Network [OSTI]

    Wang, Liping

    2014-01-01T23:59:59.000Z

    of Commercial Building HVAC Systems, Atlanta: American2012. Modeling and simulation of HVAC faults in EnergyPlus,Modeling and Simulation of HVAC Faulty Operations and

  11. Renovating Residential HVAC Systems HVAC Systems

    E-Print Network [OSTI]

    - 1 - LBNL 57406 Renovating Residential HVAC Systems HVAC Systems J.A. McWilliams and I.S. Walker Environmental Energy Technologies Division April 2005 ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY #12 Laboratory is an equal opportunity employer. This work was supported by the Assistant Secretary for Energy

  12. Model-Based Hierarchical Optimal Control Design for HVAC Systems

    E-Print Network [OSTI]

    Maasoumy, Mehdi; Pinto, Alessandro; Sangiovanni-Vincentelli, Alberto

    2014-01-01T23:59:59.000Z

    trol algorithm design for hvac systems in energy efficientH.R. Sualem. Building and HVAC System simulation with theOPTIMAL CONTROL DESIGN FOR HVAC SYSTEMS Mehdi Maasoumy,

  13. Measuring Advances in HVAC Distribution System Design

    E-Print Network [OSTI]

    Franconi, E.

    2011-01-01T23:59:59.000Z

    Gabel and Andresen, HVAC Secondary Toolkil. Atlanta: ASHRAE,P_02 Measuring Advances in HVAC Distribution System Designdesign and operation of the HVAC thermal distribution system

  14. Wireless Demand Response Controls for HVAC Systems

    E-Print Network [OSTI]

    Federspiel, Clifford

    2010-01-01T23:59:59.000Z

    Response Controls for HVAC Systems Clifford Federspiel,tests. Figure 5: Specific HVAC electric power consumptioncontrol, demand response, HVAC, wireless Executive Summary

  15. Co-simulation of innovative integrated HVAC systems in buildings

    E-Print Network [OSTI]

    Trcka, Marija

    2010-01-01T23:59:59.000Z

    General-Purpose Approach for Co-Simulation with ADAMS. In :and to scale the use of co-simulation to a large communitymore research and development. Co-simulation has been

  16. Co-simulation of innovative integrated HVAC systems in buildings

    E-Print Network [OSTI]

    Trcka, Marija

    2010-01-01T23:59:59.000Z

    Canada: International Building Perfor- mance SimulationExternal coupling between building energy simulation andexternal coupling of building energy and air ow modeling

  17. Co-simulation of innovative integrated HVAC systems in buildings

    E-Print Network [OSTI]

    Trcka, Marija

    2010-01-01T23:59:59.000Z

    Wetter, M. , 2009. Modelica-based Modeling and Simulation totools like TRNSYS or Modelica [http://www.modelica.org] have

  18. Development of HVAC System Performance Criteria Using Factorial Design and DOE-2 Simulation

    E-Print Network [OSTI]

    Hou, D.; Jones, J. W.; Hunn, B. D.; Banks, J. A.

    1996-01-01T23:59:59.000Z

    A new approach is described for the development of Heating, Ventilating, and Air-conditioning (HVAC) System Performance Criteria for the Texas Building Energy Design Standard. This approach integrates a design of experimental methodology and DOE-2...

  19. MODELING AND SIMULATION OF HVAC FAULTS IN ENERGYPLUS

    E-Print Network [OSTI]

    Basarkar, Mangesh

    2013-01-01T23:59:59.000Z

    Methodology for Secondary HVAC Systems, Doctoral Thesis,2002, Particulate Fouling of HVAC Heat Exchangers, Doctoraland diagnosis strategy for HVAC systems involving sensor

  20. A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS

    E-Print Network [OSTI]

    thresholds are exceeded. The paper presents results from testing the controller with a dual-duct air-handling unit. INTRODUCTION Heating, ventilating, and air-conditioning (HVAC) systems are typically controlled energy consumption, and increased wear on controlled elements, such as actuators, valves, and dampers

  1. Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems

    E-Print Network [OSTI]

    Najafi, Massieh

    2010-01-01T23:59:59.000Z

    in Fault Diagnostics for HVAC Systems Massieh Najafi 1 ,tools for determining HVAC diagnostics, methods todetect faults in HVAC systems are still generally

  2. Fault Detection and Diagnosis in Building HVAC Systems

    E-Print Network [OSTI]

    Najafi, Massieh

    2010-01-01T23:59:59.000Z

    Wright, “Condition monitoring in HVAC subsystems using firstmonitoring packaged HVAC equipment. ASHRAE Transactions”,Detection and Diagnosis of HVAC Systems Using Support Vector

  3. Comparisons of HVAC Simulations between EnergyPlus and DOE-2.2 for Data Centers

    E-Print Network [OSTI]

    Hong, Tianzhen

    2009-01-01T23:59:59.000Z

    ABORATORY Comparisons of HVAC Simulations between EnergyPlusemployer. Comparisons of HVAC Simulations between EnergyPlusThis paper compares HVAC simulations between EnergyPlus and

  4. CALIFORNIA ENERGY Small HVAC System Design Guide

    E-Print Network [OSTI]

    CALIFORNIA ENERGY COMMISSION Small HVAC System Design Guide DESIGNGUIDELINES October 2003 500;#12;Small HVAC System Design Guide Acknowledgements i Acknowledgements The products and outcomes presented; Darren Goody, PECI, Design Guide review. #12;Small HVAC System Design Guide Preface ii Preface The Small

  5. Energirigtige pumpekoblinger i HVAC-systemer

    E-Print Network [OSTI]

    Energirigtige pumpekoblinger i HVAC-systemer PSO 2003 - FORSKNING & UDVIKLING I EFFEKTIV energieffektive HVAC-aggregater #12;InformationomProjektnr.:335-021 PROCESSEN: Projektet er gennemført af en reguleringsprincipper, mens Exhausto har leveret HVAC-aggregat og knowhow inden for klimasystemer. Grundfos

  6. Modeling and simulation of HVAC Results in EnergyPlus

    E-Print Network [OSTI]

    LBNL-5564E Modeling and simulation of HVAC Results in EnergyPlus Mangesh Basarkar, Xiufeng Pang;MODELING AND SIMULATION OF HVAC FAULTS IN ENERGYPLUS Mangesh Basarkar, Xiufeng Pang, Liping Wang, Philip

  7. An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings

    E-Print Network [OSTI]

    Trcka, Marija

    2010-01-01T23:59:59.000Z

    Heating and Cooling Task 12B and IEA Energy Conservation inNeymark, J. and Judkoff, R. 2002. IEA HVAC BESTEST volume 1,Technical report of a IEA Solar Heating and Cooling

  8. Cooperative Control of Air Flow for HVAC Systems

    E-Print Network [OSTI]

    Shuai, Liu; Lihua, Xie

    2013-01-01T23:59:59.000Z

    in a variable air volume HVAC system,” Energy, vol. 21, no.Global optimization for overall HVAC systems-part I problemGlobal optimization for overall HVAC systems-part II problem

  9. Comparison of Control Strategies for Energy Efficient Building HVAC Systems

    E-Print Network [OSTI]

    Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

    2014-01-01T23:59:59.000Z

    optimal control design for HVAC systems. In Dynamic SystemOpti- mal control of HVAC systems in the presence of imper-consumption minimization of hvac sys- tems using model

  10. Improving efficiency of a vehicle HVAC system with comfort modeling...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    efficiency of a vehicle HVAC system with comfort modeling, zonal design, and thermoelectric devices Improving efficiency of a vehicle HVAC system with comfort modeling, zonal...

  11. Energy Efficient HVAC System for Distributed Cooling/Heating...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Efficient HVAC System for Distributed CoolingHeating with Thermoelectric Devices Energy Efficient HVAC System for Distributed CoolingHeating with Thermoelectric Devices 2012 DOE...

  12. Development of a High-Efficiency Zonal Thermoelectric HVAC System...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    a High-Efficiency Zonal Thermoelectric HVAC System for Automotive Applications Development of a High-Efficiency Zonal Thermoelectric HVAC System for Automotive Applications...

  13. Case study field evaluation of a systems approach to retrofitting a residential HVAC system

    E-Print Network [OSTI]

    Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

    2003-01-01T23:59:59.000Z

    Practices for Residential HVAC Systems”. Boston, MA. Jump,techniques for measuring HVAC grille air flows". ASHRAEPractices Guide for Residential HVAC Retrofits. LBNL 53592.

  14. Optimal Control of Building HVAC Systems in the Presence of Imperfect Predictions

    E-Print Network [OSTI]

    Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

    2014-01-01T23:59:59.000Z

    minimization of building hvac systems using model predictivealgorithm design for hvac systems in energy efficient build-optimal control design for HVAC systems,” in Dynamic System

  15. Co-design of Control Algorithm and Embedded Platformfor Building HVAC Systems

    E-Print Network [OSTI]

    Maasoumy, Mehdi; Zhu, Qi; Li, Cheng; Meggers, Forrest; Sangiovanni-Vincentelli, Alberto

    2013-01-01T23:59:59.000Z

    algorithm design for hvac systems in energy efficientOptimal control of HVAC systems in the presence of imperfectminimization of building hvac systems using model predictive

  16. Model Predictive Control of HVAC Systems: Implementation and Testing at the University of California, Merced

    E-Print Network [OSTI]

    Haves, Phillip

    2010-01-01T23:59:59.000Z

    Model Predictive Control of HVAC Systems:    Implementation and  air  conditioning  (HVAC)  account  for  27%  of  the reduction potential of HVAC systems with  active thermal 

  17. Total and Peak Energy Consumption Minimization of Building HVAC Systems Using Model Predictive Control

    E-Print Network [OSTI]

    Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

    2012-01-01T23:59:59.000Z

    optimal control design for HVAC systems,’’ in Proc. Dynamicelectricity consumption in hvac using learning- based model-algorithm design for hvac systems in energy efficient

  18. Co-simulation for performance prediction of integrated building and HVAC systems - An analysis of solution characteristics using a two-body system

    SciTech Connect (OSTI)

    Trcka, Marija; L.M. Hensena, Jan; Wetter, Michael

    2010-06-21T23:59:59.000Z

    Integrated performance simulation of buildings and heating, ventilation and airconditioning (HVAC) systems can help reducing energy consumption and increasing occupant comfort. However, no single building performance simulation (BPS) tool offers suffcient capabilities and flexibilities to analyze integrated building systems and to enable rapid prototyping of innovative building and system technologies. One way to alleviate this problem is to use co-simulation to integrate different BPS tools. Co-simulation approach represents a particular case of simulation scenario where at least two simulators solve coupled differential-algebraic systems of equations and exchange data that couples these equations during the time integration. This article analyzes how co-simulation influences consistency, stability and accuracy of the numerical approximation to the solution. Consistency and zero-stability are studied for a general class of the problem, while a detailed consistency and absolute stability analysis is given for a simple two-body problem. Since the accuracy of the numerical approximation to the solution is reduced in co-simulation, the article concludes by discussing ways for how to improve accuracy.

  19. MAPPING HVAC SYSTEMS FOR SIMULATION IN Author(s), Mangesh Basarkar, James O'Donnell, Philip

    E-Print Network [OSTI]

    Lawrence Berkeley National Laboratory, Berkeley, CA, 94720 ­ U.S.A. ABSTRACT For building energy simulation required by the whole building energy simulation tool EnergyPlus. This paper describes each stage energy simulation models are difficult to create and modify (See et al., 2011). Building geometry

  20. System Optimization - The Global Approach to HVAC Control

    E-Print Network [OSTI]

    Thielman, D. E.

    1984-01-01T23:59:59.000Z

    System Optimization is a new approach to HVAC control as implemented by Energy Management Control Systems. System Optimization is defined as electronic building control strategies which treat a building's HVAC components as a complete energy...

  1. Implementation and main results Ecient Management of HVAC Systems

    E-Print Network [OSTI]

    Schenato, Luca

    , Ventilation and Air-Conditioning System Heating, Ventilation and Air Conditioning Systems (HVAC) represents Implementation and main results HVAC Systems Multiple-chiller systems Heating, Ventilation and Air #12;Motivation Implementation and main results HVAC Systems Multiple-chiller systems Heating

  2. Theoretical Minimum Energy Use of a Building HVAC System 

    E-Print Network [OSTI]

    Tanskyi, O.

    2011-01-01T23:59:59.000Z

    This paper investigates the theoretical minimum energy use required by the HVAC system in a particular code compliant office building. This limit might be viewed as the "Carnot Efficiency" for HVAC system. It assumes that all ventilation and air...

  3. The Optimization of Control Parameters for VAV HVAC System Commissioning

    E-Print Network [OSTI]

    Song, S.; Maehara, K.; Sagara, N.

    2006-01-01T23:59:59.000Z

    One of the technical subjects in commissioning for HVAC system is to enhance control performance and time efficiency, while the tuning of the optimal parameters to control HVAC system takes much time and labor in particular. Therefore, we propose a...

  4. Theoretical Minimum Energy Use of a Building HVAC System

    E-Print Network [OSTI]

    Tanskyi, O.

    2011-01-01T23:59:59.000Z

    This paper investigates the theoretical minimum energy use required by the HVAC system in a particular code compliant office building. This limit might be viewed as the "Carnot Efficiency" for HVAC system. It assumes that all ventilation and air...

  5. Optimal Control of Building HVAC Systems in the Presence of Imperfect Predictions, ASME Dynamic System Control Conference

    E-Print Network [OSTI]

    Maasoumy, Mehdi

    2012-01-01T23:59:59.000Z

    optimal control design for HVAC systems,” in Dynamic Systemalgorithm design for hvac systems in energy efficient build-OPTIMAL CONTROL OF BUILDING HVAC SYSTEMS IN THE PRESENCE OF

  6. Implementation of a Scenario-based MPC for HVAC Systems

    E-Print Network [OSTI]

    Johansson, Karl Henrik

    Implementation of a Scenario-based MPC for HVAC Systems: an Experimental Case Study Alessandra, Ventilation and Air Conditioning (HVAC) systems play a fundamental role in maintaining acceptable thermal energy savings potential. Developing effective MPC-based control strategies for HVAC systems

  7. Modeling and Simulation of HVAC Faulty Operations and

    E-Print Network [OSTI]

    effort and coverage: 1) proactive, performance-monitored maintenance; 2) preventive, scheduled to Maintenance Issues Liping Wang, Tianzhen Hong Environmental Energy Technologies Division January 2013 and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues Liping Wang

  8. Comparison of Building Energy Modeling Programs: HVAC Systems

    E-Print Network [OSTI]

    LBNL-6432E Comparison of Building Energy Modeling Programs: HVAC Systems Xin Zhou1 , Tianzhen Hong2 programs (BEMPs) for HVAC calculations: EnergyPlus, DeST, and DOE-2.1E. This is a joint effort between purposes, BEMPs can be divided into load modules and HVAC system modules. This technical report

  9. Salsbury and Diamond: Automated Testing of HVAC Systems for Commissioning -1 -Automated Testing of HVAC Systems for Commissioning

    E-Print Network [OSTI]

    and Diamond: Automated Testing of HVAC Systems for Commissioning - 1 - Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond Lawrence Berkeley National Laboratory Berkeley, CA 94720 Synopsis This paper describes an approach to the automation of the commissioning of HVAC systems. The approach

  10. Cold Vacuum Drying facility HVAC system design description (SYS 30-1 THRU 30-5)

    SciTech Connect (OSTI)

    PITKOFF, C.C.

    1999-07-02T23:59:59.000Z

    This document describes the Cold Vacuum Drying Facility (CVDF) heating, ventilation, and air conditioning system (HVAC). The CVDF HVAC system consists of the Administrative building HVAC system, the process bay recirculation HVAC system, the process bay local HVAC and process vent system, the process general supply/exhaust HVAC system, and the Reference air system. These HVAC sub-systems support the CVDF process and provide secondary confinement of contamination and the required filtration of exhaust.

  11. Long Range Passive UHF RFID System Using HVAC Ducts

    E-Print Network [OSTI]

    Hochberg, Michael

    INVITED P A P E R Long Range Passive UHF RFID System Using HVAC Ducts To provide a potential communications channel, HVAC ducts can function as electromagnetic waveguides; a 30-m read range has been-conditioning (HVAC) ducts as a potential communication channel between passive ultrahigh-frequency (UHF) radio

  12. Pitfalls in Building and HVAC Systems

    E-Print Network [OSTI]

    Gidwani, B. N.

    PITFALLS IN BUILDING AND HVAC SYSTEMS B. N. Gidwani, P.E. Roy F. Weston, Inc. West Chester, Pennsylvania ABSTRACT The purpose of an energy audit is to identify and analyze areas of energy consumption and to pro pose methods of conservation.... In the process of completing an audit the following areas of consump tion should be considered: ? Building Envelope ? Air-Handling Systems ? Chilled Water Systems ? Boiler Systems ? Lighting/Electrical Systems Within these areas many potential...

  13. Model Predictive Control Approach to Online Computation of Demand-Side Flexibility of Commercial Buildings HVAC Systems for Supply Following

    E-Print Network [OSTI]

    Maasoumy, Mehdi

    2014-01-01T23:59:59.000Z

    of commercial building HVAC fan as ancillary service foralgorithm design for hvac systems in energy efficientoptimal control design for HVAC systems,” in Dynamic System

  14. MODELING AND SIMULATION OF HVAC FAULTS IN ENERGYPLUS

    E-Print Network [OSTI]

    Basarkar, Mangesh

    2013-01-01T23:59:59.000Z

    Symptoms Decreased boiler efficiency due to the increasedresult in reduced boiler efficiency if the sensor hasboiler and two chillers in the plant loop. The building envelope prescriptive minimums and HVAC system efficiencies

  15. Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues

    SciTech Connect (OSTI)

    Wang, Liping; Hong, Tianzhen

    2013-01-01T23:59:59.000Z

    Almost half of the total energy used in the U.S. buildings is consumed by heating, ventilation and air conditionings (HVAC) according to EIA statistics. Among various driving factors to energy performance of building, operations and maintenance play a significant role. Many researches have been done to look at design efficiencies and operational controls for improving energy performance of buildings, but very few study the impacts of HVAC systems maintenance. Different practices of HVAC system maintenance can result in substantial differences in building energy use. If a piece of HVAC equipment is not well maintained, its performance will degrade. If sensors used for control purpose are not calibrated, not only building energy usage could be dramatically increased, but also mechanical systems may not be able to satisfy indoor thermal comfort. Properly maintained HVAC systems can operate efficiently, improve occupant comfort, and prolong equipment service life. In the paper, maintenance practices for HVAC systems are presented based on literature reviews and discussions with HVAC engineers, building operators, facility managers, and commissioning agents. We categorize the maintenance practices into three levels depending on the maintenance effort and coverage: 1) proactive, performance-monitored maintenance; 2) preventive, scheduled maintenance; and 3) reactive, unplanned or no maintenance. A sampled list of maintenance issues, including cooling tower fouling, boiler/chiller fouling, refrigerant over or under charge, temperature sensor offset, outdoor air damper leakage, outdoor air screen blockage, outdoor air damper stuck at fully open position, and dirty filters are investigated in this study using field survey data and detailed simulation models. The energy impacts of both individual maintenance issue and combined scenarios for an office building with central VAV systems and central plant were evaluated by EnergyPlus simulations using three approaches: 1) direct modeling with EnergyPlus, 2) using the energy management system feature of EnergyPlus, and 3) modifying EnergyPlus source code. The results demonstrated the importance of maintenance for HVAC systems on energy performance of buildings. The research is intended to provide a guideline to help practitioners and building operators to gain the knowledge of maintaining HVAC systems in efficient operations, and prioritize HVAC maintenance work plan. The paper also discusses challenges of modeling building maintenance issues using energy simulation programs.

  16. Methodology to Analyze the Sensitivity of Building Energy Consumption to HVAC System Sensor Error 

    E-Print Network [OSTI]

    Ma, Liang

    2012-02-14T23:59:59.000Z

    This thesis proposes a methodology for determining sensitivity of building energy consumption of HVAC systems to sensor error. It is based on a series of simulations of a generic building, the model for which is based on several typical input...

  17. Thermal Storage Options for HVAC Systems

    E-Print Network [OSTI]

    Weston, R. F.; Gidwani, B. N.

    THERMAL STORAGE OPTIONS FOR HVAC SYSTEMS B. N. Gidwani, P.E. Roy F. Weston, Inc. West Chester, Pennsylvania ABSTRACT With the ever-increasing cost of electricity and the high demand charges levied by utility compa nies, thermal storage... for cooling is rapidly becom ing a widely recognized method to lower cooling costs. There are three maior types of thermal stor age systems: ? Ice Storage: This utilizes the latent heat of fusion of ice for thermal storage. During off Deak periods...

  18. Reliability and Functional Availability of HVAC Systems

    E-Print Network [OSTI]

    Myrefelt, S.

    2004-01-01T23:59:59.000Z

    RELIABILITY AND FUNCTIONAL AVAILABILITY OF HVAC SYSTEMS Sonny Myrefelt Dep. of Build. Serv. Eng., KTH, 10044 Stockholm, Sweden, and SKANSKA Sydost, V?xj?, Sweden Summary This paper presents a model to calculate the reliability... system, therefore, there must be sufficient documentation of design airflow rates. The compulsory ventilation checks performed in Sweden have focused on the importance of maintaining the design air flow rates. More about this activity can be seen...

  19. Analysis of a hybrid UFAD and radiant hydronic slab HVAC system

    E-Print Network [OSTI]

    Raftery, Paul; Lee, Kwang Ho; Webster, Thomas; Bauman, Fred

    2011-01-01T23:59:59.000Z

    Air- Conditioning Engineers HVAC & R Research, vol. 50, Sep.and radiant hydronic slab HVAC system.   Paul RAFTERY a,* ,of a novel integrated HVAC system. This system combines an

  20. Integration of HVAC System Design with Simplified Duct Distribution...

    Energy Savers [EERE]

    about this Top Innovation. See an example of this Top Innovation in action. Find more case studies of Building America projects across the country that integrate HVAC system...

  1. Improving the Efficiency of Light-Duty Vehicle HVAC Systems using...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Light-Duty Vehicle HVAC Systems using Zonal Thermoelectric Devices and Comfort Modeling Improving the Efficiency of Light-Duty Vehicle HVAC Systems using Zonal Thermoelectric...

  2. A Scenario-based Predictive Control Approach to Building HVAC Management Systems

    E-Print Network [OSTI]

    Johansson, Karl Henrik

    A Scenario-based Predictive Control Approach to Building HVAC Management Systems Alessandra Parisio and Air Conditioning (HVAC) systems while minimizing the overall energy use. The strategy uses

  3. Thinking small leads to efficient HVAC system

    SciTech Connect (OSTI)

    Not Available

    1981-06-01T23:59:59.000Z

    The energy efficient design of a Park Avenue office tower is discussed. The 27 story, 260,000 sq. ft. building features an energy efficient HVAC system, including separate mechanical rooms on each floor and a pre-cooling coil utilizing water from a cooling tower. The building was designed so that condenser water from the cooling tower is run through a pre-cooling coil on each floor in order to provide free cooling before the water goes through the condenser coil. The building also uses a Honeywell energy management system to control the start and stop of various mechanical equipment according to outside conditions and building loads. (MJF)

  4. Design and tuning of robust PID controller for HVAC systems

    SciTech Connect (OSTI)

    Kasahara, Masato; Matsuba, Tadahiko; Kuzuu, Yoshiaki; Yamazaki, Takanori; Hashimoto, Yukihiro; Kamimura, Kazuyuki; Kurosu, Shigeru

    1999-07-01T23:59:59.000Z

    This paper concerns the development of a new design and tuning method for use with robust proportional-plus-integral-plus-derivative (PID) controllers that are commonly used in the heating, ventilating, and air-conditioning (HVAC) fields. The robust PID controller is designed for temperature control of a single-zone environmental space. Although the dynamics of environmental space are described by higher-order transfer functions, most HVAC plants are approximated by first-order lag plus deadtime systems. Its control performance is examined for this commonly approximated controlled plant. Since most HVAC plants are complex with nonlinearity, distributed parameters, and multivariables, a single set of PID gains does not necessarily yield a satisfactory control performance. For this reason, the PID controller must be designed as a robust control system considering model uncertainty caused by changes in characteristics of the plant. The PID gains obtained by solving a two-disk type of mixed sensitivity problem can be modified by contrast to those tuned by the traditional Ziegler-Nichols rule. The results, which are surprisingly simple, are given as linear functions of ratio of deadtime to time constant for robustness. The numerical simulation and the experiments on a commercial-size test plant for air conditioning suggest that the robust PID controller proposed in this paper is effective enough for practical applications.

  5. Energy efficient HVAC system features thermal storage and heat recovery

    SciTech Connect (OSTI)

    Bard, E.M. (Bard, Rao + Athanas Consulting Engineering Inc., Boston, MA (United States))

    1994-03-01T23:59:59.000Z

    This article describes a HVAC system designed to efficiently condition a medical center. The topics of the article include energy efficient design of the HVAC system, incentive rebate program by the local utility, indoor air quality, innovative design features, operations and maintenance, payback and life cycle cost analysis results, and energy consumption.

  6. HVAC & Building Management Control System Energy Efficiency Replacements

    SciTech Connect (OSTI)

    Hernandez, Adriana

    2012-09-21T23:59:59.000Z

    The project objective was the replacement of an aging, un-repairable HVAC system which has grown inefficient and a huge energy consumer with low energy and efficient HVAC units, and installation of energy efficient building control technologies at City's YMCA Community Center.

  7. Analysis of a hybrid UFAD and radiant hydronic slab HVAC system

    E-Print Network [OSTI]

    Raftery, Paul; Lee, Kwang Ho; Webster, Thomas; Bauman, Fred

    2011-01-01T23:59:59.000Z

    cooling systems,” American Society of Heating, Refrigerating and Air- Conditioning Engineers HVAC & R Research,

  8. The influence of HVAC systems on secondary organic aerosol formation Michael S. Waring1

    E-Print Network [OSTI]

    Siegel, Jeffrey

    The influence of HVAC systems on secondary organic aerosol formation Michael S. Waring1 , Jeffrey A, ventilation, and air- conditioning (HVAC) system. This study models the influence of HVAC systems on SOA. The most influential HVAC parameters are the flow rates, particle filtration, and indoor temperature

  9. OBSERVE: Occupancy-Based System for Efficient Reduction of HVAC Energy

    E-Print Network [OSTI]

    Carreira-Perpiñán, Miguel Á.

    OBSERVE: Occupancy-Based System for Efficient Reduction of HVAC Energy Varick L. Erickson, Miguel Á & control General Terms Algorithms, Machine Learning, Measurement Keywords Occupancy, HVAC, Ventilation for heating, ventilation, and air-conditioning (HVAC) systems[2]. Studies suggest that 15% to 25% of HVAC

  10. Building HVAC Control System Interaction Issues: Two Case Studies

    E-Print Network [OSTI]

    Chen, Q.; Deng, S.; Toole, C.; Xu, C.

    2007-01-01T23:59:59.000Z

    Direct Digital Control (DDC) allows HVAC equipment to be controlled at an upper level (supervisory control) through commands from a central system, or at a lower-level (local-loop control) by local controllers. The various levels of equipment...

  11. A PDI for your HVAC System

    Broader source: Energy.gov [DOE]

    This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question "HVAC proper installation energy savings: over-promising or under-deliverying?"

  12. Comparisons of HVAC Simulations between EnergyPlus and DOE-2.2 for Data Centers

    SciTech Connect (OSTI)

    Hong, Tianzhen; Sartor, Dale; Mathew, Paul; Yazdanian, Mehry

    2008-08-13T23:59:59.000Z

    This paper compares HVAC simulations between EnergyPlus and DOE-2.2 for data centers. The HVAC systems studied in the paper are packaged direct expansion air-cooled single zone systems with and without air economizer. Four climate zones are chosen for the study - San Francisco, Miami, Chicago, and Phoenix. EnergyPlus version 2.1 and DOE-2.2 version 45 are used in the annual energy simulations. The annual cooling electric consumption calculated by EnergyPlus and DOE-2.2 are reasonablely matched within a range of -0.4percent to 8.6percent. The paper also discusses sources of differences beween EnergyPlus and DOE-2.2 runs including cooling coil algorithm, performance curves, and important energy model inputs.

  13. COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM

    SciTech Connect (OSTI)

    Jiang Zhu; Yong X. Tao

    2011-11-01T23:59:59.000Z

    In this paper, a hotel with hybrid geothermal heat pump system (HyGSHP) in the Pensacola is selected and simulated by the transient simulation software package TRNSYS [1]. To verify the simulation results, the validations are conducted by using the monthly average entering water temperature, monthly facility consumption data, and etc. And three types of HVAC systems are compared based on the same building model and HVAC system capacity. The results are presented to show the advantages and disadvantages of HyGSHP compared with the other two systems in terms of energy consumptions, life cycle cost analysis.

  14. Review of Residential Low-Load HVAC Systems

    SciTech Connect (OSTI)

    Brown, Scott A.; Thornton, Brian; Widder, Sarah H.

    2013-09-01T23:59:59.000Z

    In support of the U.S. Department of Energy’s (DOE’s) Building America Program, Pacific Northwest National Laboratory (PNNL) conducted an investigation to inventory commercially available HVAC technologies that are being installed in low-load homes. The first step in this investigation was to conduct a review of published literature to identify low-load HVAC technologies available in the United States and abroad, and document the findings of existing case studies that have evaluated the performance of the identified technologies. This report presents the findings of the literature review, identifies gaps in the literature or technical understanding that must be addressed before low-load HVAC technologies can be fully evaluated, and introduces PNNL’s planned research and analysis for this project to address identified gaps and potential future work on residential low-load HVAC systems.

  15. Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage

    E-Print Network [OSTI]

    Mammoli, Andrea

    2014-01-01T23:59:59.000Z

    solar-thermal- assisted hvac system. Energy and Buildings, [of a Solar-Assisted HVAC System with Thermal Storage A.of a solar-assisted HVAC system with thermal storage. Energy

  16. A standard simulation testbed for the evaluation of control algorithms & strategies related to variable air volume HVAC systems

    E-Print Network [OSTI]

    DeSimone, Mark

    1995-01-01T23:59:59.000Z

    The parameters for a dynamic, computer simulation model were developed. The parameters characterize the physical and geometric properties of a building shell, the internal and external building loads, the buildings secondary ...

  17. Using measured equipment load profiles to "right-size" HVAC systems and reduce energy use in laboratory buildings (Pt. 2)

    E-Print Network [OSTI]

    Mathew, Paul; Greenberg, Steve; Frenze, David; Morehead, Michael; Sartor, Dale; Starr, William

    2008-01-01T23:59:59.000Z

    load profiles to “right-size” HVAC systems and reduce energyGeorgia. ASHRAE [1999]. HVAC Applications Handbook 1999.Inefficiency of a Common Lab HVAC System,” presented at the

  18. Energy-Efficient Building HVAC Control Using Hybrid System LBMPC

    E-Print Network [OSTI]

    Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

    2012-01-01T23:59:59.000Z

    Improving the energy-efficiency of heating, ventilation, and air-conditioning (HVAC) systems has the potential to realize large economic and societal benefits. This paper concerns the system identification of a hybrid system model of a building-wide HVAC system and its subsequent control using a hybrid system formulation of learning-based model predictive control (LBMPC). Here, the learning refers to model updates to the hybrid system model that incorporate the heating effects due to occupancy, solar effects, outside air temperature (OAT), and equipment, in addition to integrator dynamics inherently present in low-level control. Though we make significant modeling simplifications, our corresponding controller that uses this model is able to experimentally achieve a large reduction in energy usage without any degradations in occupant comfort. It is in this way that we justify the modeling simplifications that we have made. We conclude by presenting results from experiments on our building HVAC testbed, which s...

  19. Direct Digital Control- A Tool for Energy Management of HVAC Systems

    E-Print Network [OSTI]

    Swanson, K.

    Direct digital control (DDC) applied to heating, ventilating, and air-conditioning (HVAC) systems corrects many of the deficiencies of conventional automatic temperature control systems. By applying new control sequences, DDC optimizes HVAC energy...

  20. Simulation of Control Options for HVAC Management of a Typical Office Julien CAILLET julien.caillet@mines-paristech.fr

    E-Print Network [OSTI]

    Boyer, Edmond

    Simulation of Control Options for HVAC Management of a Typical Office Building. Julien CAILLET thermal comfort and to reduce energy consumption of buildings. Among defect correction, HVAC control appears as a way of significant improvement. HVAC control is examined by using a dynamic simulation

  1. Multicriteria Genetic Tuning for the Optimization and Control of HVAC Systems

    E-Print Network [OSTI]

    Casillas Barranquero, Jorge

    Multicriteria Genetic Tuning for the Optimization and Control of HVAC Systems Rafael Alcala1, Jose of genetic algorithms for the optimization and control of Heating, Ventilating and Air Conditioning (HVAC of these systems. An optimum operation of the HVAC systems is a necessary condition for mini- mizing energy

  2. Fuzzy Rule Reduction and Tuning of Fuzzy Logic Controllers for a HVAC System

    E-Print Network [OSTI]

    Granada, Universidad de

    Fuzzy Rule Reduction and Tuning of Fuzzy Logic Controllers for a HVAC System R. Alcal´a, J. Alcal, Ventilating and Air Conditioning (HVAC) Systems are equip- ments usually implemented for maintaining satisfactory comfort conditions in build- ings. The design of Fuzzy Logic Controllers (FLCs) for HVAC Systems

  3. Tile of the document: HVAC system component-based modeling and implementation

    E-Print Network [OSTI]

    Austin, Mark

    1 Abstract Tile of the document: HVAC system component-based modeling and implementation Karam the foundation for modeling components that are used in HVAC systems (heating, ventilation, and air conditioning such functionalities. #12;2 HVAC system component-based modeling and implementation By Karam H. Rajab Scholarly

  4. BLACK-BOX MODELLING OF HVAC SYSTEM: IMPROVING THE PERFORMANCES OF NEURAL NETWORKS

    E-Print Network [OSTI]

    Boyer, Edmond

    BLACK-BOX MODELLING OF HVAC SYSTEM: IMPROVING THE PERFORMANCES OF NEURAL NETWORKS Eric FOCK Ile de La Réunion - FRANCE ABSTRACT This paper deals with neural networks modelling of HVAC systems of HVAC system can be modelled using manufacturer design data presented as derived performance maps

  5. Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable-Speed-Drive Chillers

    E-Print Network [OSTI]

    -Speed-Drive Chillers Tengfang Xu June 15, 2005 The project is funded by the California Energy Commission's Industrial Efficient Cleanrooms Efficient HVAC Water Systems: Variable-Speed-Drive Chillers Tengfang Xu Contents HVAC.............................................................................................. 2 Variable-Speed-Drive Chillers

  6. RF propagation in an HVAC duct system: impulse response characteristics of the channel

    E-Print Network [OSTI]

    Stancil, Daniel D.

    RF propagation in an HVAC duct system: impulse response characteristics of the channel Pavel V, the heating, ventilation, and air conditioning (HVAC) duct system in buildings is a complex network of hollow at RF and microwave frequencies of com- mon interest. HVAC ducts can be used as a wireless communication

  7. RoomZoner: Occupancy-based Room-Level Zoning of a Centralized HVAC System

    E-Print Network [OSTI]

    Whitehouse, Kamin

    RoomZoner: Occupancy-based Room-Level Zoning of a Centralized HVAC System Tamim Sookoor & Kamin. In this paper we present a CPS that enables a centralized Heating, Ventila- tion, and Air Conditioning (HVAC application due to residential HVAC systems ac- counting for over 15% of all U.S. energy usage, making it one

  8. Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings

    E-Print Network [OSTI]

    Mountziaris, T. J.

    Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings Tom Rogg REU Student are important considerations in building design. Incorporation of a combination of passive ventilation systems of the National Science Foundation. Research Objectives · To provide proof of concept that a passive ventilation

  9. Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture

    E-Print Network [OSTI]

    Stancil, Daniel D.

    Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture Ariton E. Xhafa, Paisarn-- In this paper, we present an innovative solution to the handover problem in multi-story buildings using HVAC of the indoor wireless networks that use the heating, ventilation, and air conditioning (HVAC) ducts

  10. Randomized Model Predictive Control for HVAC Systems Alessandra Parisio, Damiano Varagnolo, Daniel Risberg,

    E-Print Network [OSTI]

    Johansson, Karl Henrik

    Randomized Model Predictive Control for HVAC Systems Alessandra Parisio, Damiano Varagnolo, Daniel Conditioning (HVAC) sys- tems play a fundamental role in maintaining acceptable ther- mal comfort and Indoor. A possible solu- tion is to develop effective control strategies for HVAC sys- tems, but this is complicated

  11. A systems approach to retrofitting residential HVAC systems

    SciTech Connect (OSTI)

    McWilliams, J.A.; Walker, I.S.

    2004-05-01T23:59:59.000Z

    A Best Practices Guide for retrofitting residential HVAC systems has recently been completed by DOE. The guide uses diagnostics and checklists to guide the user to specific retrofit packages that maximize retrofit energy savings, comfort and safety potential. The guide uses a systems approach to retrofitting where the interaction of different building components is considered throughout the retrofit selection process. For example, added building envelope insulation reduces building loads so that smaller capacity HVAC systems can be used. In this study, several houses were surveyed using the Best Practices Guide and a single house was selected for retrofitting. The objectives were to demonstrate how a successful system-wide retrofit can be carried out and to provide feedback to improve the guide. Because it represents a departure from current practice, a key aspect of this study was to investigate the interactions with contractors and code officials who are unfamiliar with the systems approach. The study found that the major barrier to the systems approach in retrofits was in changing the working practices of contractors and code officials.

  12. Measuring Advances in HVAC Distribution System Design

    SciTech Connect (OSTI)

    Franconi, E.

    1998-05-01T23:59:59.000Z

    Substantial commercial building energy savings have been achieved by improving the performance of the HV AC distribution system. The energy savings result from distribution system design improvements, advanced control capabilities, and use of variable-speed motors. Yet, much of the commercial building stock remains equipped with inefficient systems. Contributing to this is the absence of a definition for distribution system efficiency as well as the analysis methods for quantifying performance. This research investigates the application of performance indices to assess design advancements in commercial building thermal distribution systems. The index definitions are based on a first and second law of thermodynamics analysis of the system. The second law or availability analysis enables the determination of the true efficiency of the system. Availability analysis is a convenient way to make system efficiency comparisons since performance is evaluated relative to an ideal process. A TRNSYS simulation model is developed to analyze the performance of two distribution system types, a constant air volume system and a variable air volume system, that serve one floor of a large office building. Performance indices are calculated using the simulation results to compare the performance of the two systems types in several locations. Changes in index values are compared to changes in plant energy, costs, and carbon emissions to explore the ability of the indices to estimate these quantities.

  13. Using Energy Management Control Systems for HVAC Operational Diagnostics

    E-Print Network [OSTI]

    Stum, K.

    1998-01-01T23:59:59.000Z

    USING ENERGY MANAGEMENT CONTROL SYSTEMS FOR HVAC OPERATIONAL DIAGNOSTICS Karl Stum, P.E. Portland Energy Conservation, Inc. 92 1 SW Washington, Suite 3 12 Portland, OR 97205 503-248-4636 Fax 503-295-0820 ABSTRACT The power and flexibility... Proceedings, June 1997. Meyers, S.; E. Mills; A. Chen; L. Demsetz "Building Data Visualization for Diagnostics," ASHRAE Journal, June 1996. PECl (Portland Energy Conservation, Inc.). Energy Management C0ntrof Systems-A Practical Guiak, 1997. Sparks, R...

  14. Total Quality Commissioning for HVAC Systems to Assure High Performance Throughout the Whole Life Cycle 

    E-Print Network [OSTI]

    Maisey, G.; Milestone, B.

    2005-01-01T23:59:59.000Z

    TOTAL QUALITY COMMISSIONING FOR HVAC SYSTEMS TO ASSURE HIGH PERFORMANCE THROUGHOUT THE WHOLE LIFE CYCLE By: Grahame E. Maisey, P.E., and Beverly Milestone, LEED AP Building Services Consultants INTRODUCTION Current HVAC systems... not provide a life cycle, high performance assurance program. Continuous commissioning is being used to continually adjust the HVAC systems to regain good performance from the original systems, but again, is not a life cycle, high performance assurance...

  15. NREL research determines optimal HVAC system design for proper air mixing and thermal comfort in homes.

    E-Print Network [OSTI]

    NREL research determines optimal HVAC system design for proper air mixing and thermal comfort in homes. As U.S. homes become more energy efficient, heating, ventilation, and cooling (HVAC) systems to optimize overall space conditioning system design in both heating and cooling modes. Potential Impact

  16. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (http://www.hvac.okstate.edu).

    E-Print Network [OSTI]

    . For these reasons, ground-coupled heat pump systems are potentially more efficient than conven- tional air-to-air -Source Heat Pump System Models in an Integrated Building and System Simulation Environment. HVAC&R Research 12 and Validation of Ground-Source Heat Pump System Models in an Integrated Building and System Simulation

  17. Proposal for the Award of a Contract for Maintenance, Operation and Minor Installation Work for CERN Cooling and HVAC Systems

    E-Print Network [OSTI]

    1996-01-01T23:59:59.000Z

    Proposal for the Award of a Contract for Maintenance, Operation and Minor Installation Work for CERN Cooling and HVAC Systems

  18. Case study field evaluation of a systems approach to retrofitting a residential HVAC system

    SciTech Connect (OSTI)

    Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

    2003-09-01T23:59:59.000Z

    This case study focusing on a residence in northern California was undertaken as a demonstration of the potential of a systems approach to HVAC retrofits. The systems approach means that other retrofits that can affect the HVAC system are also considered. For example, added building envelope insulation reduces building loads so that smaller capacity HVAC system can be used. Secondly, we wanted to examine the practical issues and interactions with contractors and code officials required to accomplish the systems approach because it represents a departure from current practice. We identified problems in the processes of communication and installation of the retrofit that led to compromises in the final energy efficiency of the HVAC system. These issues must be overcome in order for HVAC retrofits to deliver the increased performance that they promise. The experience gained in this case study was used to optimize best practices guidelines for contractors (Walker 2003) that include building diagnostics and checklists as tools to assist in ensuring the energy efficiency of ''house as a system'' HVAC retrofits. The best practices guidelines proved to be an excellent tool for evaluating the eight existing homes in this study, and we received positive feedback from many potential users who reviewed and used them. In addition, we were able to substantially improve the energy efficiency of the retrofitted case study house by adding envelope insulation, a more efficient furnace and air conditioner, an economizer and by reducing duct leakage.

  19. Index to Evaluate Energy Efficiency of the Building HVAC System

    E-Print Network [OSTI]

    Wang, L.; Wang, L.; Claridge,D.

    2014-01-01T23:59:59.000Z

    1An Index to Evaluate Energy Efficiency of the Entire Building HVAC System Presented by Dr. Claridge Date: 09/15/2014 ESL-IC-14-09-15 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14...-17, 2014 2Outline •Why we need the Energy/Load Ratio •How to get the Energy/Load Ratio •Methodology Adjustment •Case Study •Results Showed by tables and Plots ESL-IC-14-09-15 Proceedings of the 14th International Conference for Enhanced Building Operations...

  20. Measurements of Smoke Characteristics in HVAC Ducts 

    E-Print Network [OSTI]

    Wolin, Steven D; Ryder, Noah L; Leprince, Frederic; Milke, James; Mowrer, Frederick; Torero, Jose L

    2001-01-01T23:59:59.000Z

    The characteristics of smoke traveling in an HVAC duct have been observed along with the response of selected duct smoke detectors. The simulated HVAC system consists of a 9 m long duct, 0.45 m in diameter. An exhaust fan is placed at one end...

  1. Design of Control Systems for HVAC Applications

    E-Print Network [OSTI]

    Smith, A. L.

    1984-01-01T23:59:59.000Z

    The design and application of temperature control systems on a commercial building will bring the question to mind: Should the system be Pneumatic? Should it be Electronic? There is concern as to which system will be more appropriate to a certain...

  2. Design of Control Systems for HVAC Applications 

    E-Print Network [OSTI]

    Smith, A. L.

    1984-01-01T23:59:59.000Z

    The design and application of temperature control systems on a commercial building will bring the question to mind: Should the system be Pneumatic? Should it be Electronic? There is concern as to which system will be more appropriate to a certain...

  3. Wireless Demand Response Controls for HVAC Systems

    SciTech Connect (OSTI)

    Federspiel, Clifford

    2009-06-30T23:59:59.000Z

    The objectives of this scoping study were to develop and test control software and wireless hardware that could enable closed-loop, zone-temperature-based demand response in buildings that have either pneumatic controls or legacy digital controls that cannot be used as part of a demand response automation system. We designed a SOAP client that is compatible with the Demand Response Automation Server (DRAS) being used by the IOUs in California for their CPP program, design the DR control software, investigated the use of cellular routers for connecting to the DRAS, and tested the wireless DR system with an emulator running a calibrated model of a working building. The results show that the wireless DR system can shed approximately 1.5 Watts per design CFM on the design day in a hot, inland climate in California while keeping temperatures within the limits of ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy.

  4. Energy Conservation Studies of Existing HVAC Systems

    E-Print Network [OSTI]

    Patterson, C. L.; Phelan, T. R.

    and control system (EMCS) can provide the energy.savings of the local microprocessor control system and also be used to moni to r buil di ng energy consumption. An EMCS application program for monitori ng operation conditions of air handling units would... be corrected. Construction cost of an EMCS for monitori ng of the 25 ai r handl i ng sys tems was es timated to be about .$260,000. Estimated energy saving fran monitoring is $170,000 per year. An EMCS capable of both monitori ng and control of the 25 air...

  5. ETME 422 -REFRIGERATION & HVAC SYSTEMS FALL 2011 LEC -10:00 -10:50am M W F RH 312

    E-Print Network [OSTI]

    Dyer, Bill

    10/31/2011 ETME 422 - REFRIGERATION & HVAC SYSTEMS FALL 2011 LEC - 10:00 - 10:50am M W F RH 312. -- Refrigeration and heating, ventilating and air-conditioning (HVAC) for comfort and industrial applications, low temperature refrigeration cycles; air distribution and fan-duct analysis, design/selection of HVAC

  6. Minimization of energy consumption in HVAC systems with data-driven models and an interior-point method

    E-Print Network [OSTI]

    Kusiak, Andrew

    Minimization of energy consumption in HVAC systems with data-driven models and an interior-driven approach is applied to minimize energy consumption of a heating, ventilating, and air conditioning (HVAC online 13 June 2014 Keywords: HVAC Interior-point method Internal heat gain Multilayer perceptron

  7. Joint-Frequency Bins versus Conventional Bin Weather Data in Analysis of HVAC System Operation

    E-Print Network [OSTI]

    Jones, A.; Baltazar, J. C.; Claridge, D. E.

    this study the use of joint-frequency bins has relative added value to the analysis of HVAC system operation depending on whether the system is dominated by ventilation loads....

  8. Requirements for Commissioning HVAC Systems Using BEMS and Commissioning the BEMS Itself Based on Questionnaire Surveys

    E-Print Network [OSTI]

    Yoshida, H.; Vaezi-Nejad, H.; Choiniere, D.; Wang, F.

    2004-01-01T23:59:59.000Z

    In this paper the present status and requirements for commissioning of HVAC Systems using Building Energy Management Systems (BEMS) and commissioning the BEMS itself are investigated and summarized. The information presented is based on the results...

  9. A Qualitive Modeling Approach for Fault Detection and Diagnosis on HVAC Systems

    E-Print Network [OSTI]

    Muller, T.; Rehault, N.; Rist, T.

    2013-01-01T23:59:59.000Z

    This paper describes the basics and first test results of a model based approach using qualitative modeling to perform Fault Detection and Diagnostics (FDD) on HVAC and R systems. A quantized system describing the qualitative behavior of a...

  10. Airborne Particulate Matter in HVAC Systems and its Influence on Indoor Air Quality

    E-Print Network [OSTI]

    Fu, Z.; Li, N.; Wang, H.

    2006-01-01T23:59:59.000Z

    ], microorganisms [2], in the case of abnormal maintenance. Because there are all kinds of components in the duct systems, tapping the law of particle distribution in HVAC systems is not an easy work. Generally speaking, flow in the duct system... is turbulent except those in some kind of components like filters. Particle movement, especially particle deposition, is strongly related to organized structures in near-wall turbulence [3]. The mechanisms governing particle transport in HVAC systems...

  11. IFC HVAC interface to EnergyPlus - A case of expanded interoperability for energy simulation

    E-Print Network [OSTI]

    Bazjanac, Vladimir; Maile, Tobias

    2004-01-01T23:59:59.000Z

    D. Sucic and P. Xu. 2002. HVAC Component Data Modeling Using2001. BS-8 project: IFC HVAC extension schemata. http://IFC HVAC INTERFACE TO ENERGYPLUS – A CASE OF EXPANDED

  12. CO2 - Based Demand-Controlled Ventilation Control Strategies for Multi-Zone HVAC Systems

    E-Print Network [OSTI]

    Nassif, N.

    2011-01-01T23:59:59.000Z

    CO2-based demand-controlled ventilation DCV strategy offers a great opportunity to reduce energy consumption in HVAC systems while providing the required ventilation. However, implementing CO2-based DCV under ASHRAE 62.1.2004 through 2010...

  13. Computational Study on Thermal Properties of HVAC System with Building Structure Thermal Storage

    E-Print Network [OSTI]

    Sato, Y.; Sagara, N.; Ryu, Y.; Maehara, K.; Nagai, T.

    2007-01-01T23:59:59.000Z

    Building structure thermal storage (BSTS) HVAC systems can store heat during nighttime thermal storage operation (nighttime operation hours) by using off-peak electricity and release it in the daytime air-conditioning operation (daytime operation...

  14. A Unified and Integrated Energy Management System for HVAC Spaces and Power House 

    E-Print Network [OSTI]

    Kaya, A.; Debban, G. D.

    1988-01-01T23:59:59.000Z

    This paper describes a totally integrated energy management system throughout the plant and facilities. The equipment involves: the power plant (boilers, cogeneration turbines, chillers); HVAC of buildings; air handling and other distribution...

  15. Application of Various HVAC Simulation Programs and Visual Tools to Commissioning 

    E-Print Network [OSTI]

    Zheng, M.; Pan, S.

    2007-01-01T23:59:59.000Z

    , aperture size etc., Calculate PAL and BEE Calculate PAL and BEE with BECS,CASBEE Buil- ding Plan/ Design Cx Optimize building location, envelop structure, aperture size, and aperture position etc. Simulate heat load and natural room temperature yearly... peak heat load by using MicroPeak, confirm airflow, thermal environment by CFD Preliminary design Cx Optimize HVAC, heat source, equipment capacity, number division of equipment Calculate hourly heat load through the year in detail Normal...

  16. Validation of a Building Simulation Tool Using Field Data for Three Identical Configuration Full-Serve Restaurants Using Different HVAC Systems

    E-Print Network [OSTI]

    Brillhart, P. L.; Worek, W. M.

    2000-01-01T23:59:59.000Z

    and Spears (2000), for three full-service restaurants. A standard vapor-compression system, an enthalpy assisted vapor-compression system, and a desiccant-assisted vapor-compression system are compared. The vapor-compression portion of each system...

  17. Distributed scheduling for efficient HVAC precooling operations

    E-Print Network [OSTI]

    Yang, Su

    2014-01-01T23:59:59.000Z

    of supply and return fans for HVAC systems under di?erentOp- timal Scheduling of HVAC Pre-cooling Operations withScheduling for E?cient HVAC Pre-cooling Operations ? Yang

  18. Application of black-box models to HVAC systems for fault detection

    SciTech Connect (OSTI)

    Peitsman, H.C. [TNO Building and Construction Research, Delft (Netherlands). Dept. of Indoor Environment, Building Physics and Systems; Bakker, V.E. [Univ. of Twente, Enschede (Netherlands). Dept. of Computer Science

    1996-11-01T23:59:59.000Z

    This paper describes the application of black-box models for fault detection and diagnosis (FDD) in heating, ventilating, and air-conditioning (HVAC) systems. In this study, multiple-input/single-output (MISO) ARX models and artificial neural network (ANN) models are used. The ARX models are examined for different processes and subprocesses and compared with each other. Two types of models are established--system models and component models. In the case of system models, the HVAC system as a whole is regarded as a black box instead of as a collection of component models. With the component model type, the components of the HVAC system are regarded as separate black boxes.

  19. MAPPING HVAC SYSTEMS FOR SIMULATION IN ENERGYPLUS

    E-Print Network [OSTI]

    Basarkar, Mangesh

    2013-01-01T23:59:59.000Z

    apps1.eere.energy.gov/buildings/energyplus/. Modelica, 2012.Modelica andthe Modelica Association — Modelica Association [WWW

  20. Flexibility of Commercial Building HVAC Fan as Ancillary Service for Smart Grid

    E-Print Network [OSTI]

    Maasoumy, Mehdi

    2013-01-01T23:59:59.000Z

    optimal control design for HVAC systems,” in Dynamic Systemminimization of building hvac systems using model pre-algorithm design for hvac systems in energy efficient

  1. Cooperative Control of Air Flow for HVAC Systems Shuai Liu1,2, Yushen Long1, Lihua Xie1 and Alexandre M. Bayen3

    E-Print Network [OSTI]

    Cooperative Control of Air Flow for HVAC Systems Shuai Liu1,2, Yushen Long1, Lihua Xie1 for building heating, ven- tilation and air-conditioning (HVAC) systems. The strategy consists in two level and the HVAC system parameters. I. INTRODUCTION In recent years, energy saving and environment protection have

  2. A Quasi-Dynamic HVAC and Building Simulation Methodology 

    E-Print Network [OSTI]

    Davis, Clinton Paul

    2012-07-16T23:59:59.000Z

    functions, such as maintaining the water level in a boiler, controlling the output water temperature of a chiller, and throttling a fan. As a result of the numerous system configurations available, the method of control used in a particular control system...

  3. Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond

    E-Print Network [OSTI]

    Diamond, Richard

    carrying out a proof of operation. In large modern buildings, the energy management and control system to exercise systems while under closed-loop control. The test signals are in the form of setpoint changesAutomated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond Lawrence Berkeley

  4. Electric, Gas, and Electric/Gas Energy Options for Cold-Air HVAC Systems

    E-Print Network [OSTI]

    Meckler, G.

    1989-01-01T23:59:59.000Z

    and incorporated into HVAC design for medium-to-large buildings, it is possible to structure system arrangements that reduce energy operating costs very significantly compared to conventional all-air VAV systems and also to all-air VAV ice thermal storage systems...

  5. A Quasi-Dynamic HVAC and Building Simulation Methodology

    E-Print Network [OSTI]

    Davis, Clinton Paul

    2012-07-16T23:59:59.000Z

    Circuit Branch ......................................... 56 Figure 4-40 ? Calculated Cold Water Loop Pressures ..................................................... 57 Figure 5-1 ? A Single Duct Constant Air Volume System... for approximately 25% of the flow through fans. In commercial duct systems, most of this leakage typically occurs at joints versus the seams. Leakage rates typically vary as an exponential function of the static pressure difference at the duct?s surface (Aydin...

  6. Procedures to identify Energy Conservation Opportunities applied to HVAC system: example of VSD of chilled water pumps

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Procedures to identify Energy Conservation Opportunities applied to HVAC system: example of VSD among the list of Energy Conservation Opportunities (137) identified in the HARMONAC project [1]. First of HVAC equipment using variable speed drive (VSD) is an Energy Conservation Opportunity (ECO) which can

  7. Integrated high efficiency blower apparatus for HVAC systems

    DOE Patents [OSTI]

    Liu, Xiaoyue; Weigman, Herman; Wang, Shixiao

    2007-07-24T23:59:59.000Z

    An integrated centrifugal blower wheel for a heating, ventilation and air conditioning (HVAC) blower unit includes a first blade support, a second blade support, and a plurality of S-shaped blades disposed between the first and second blade supports, wherein each of the S-shaped blades has a trailing edge bent in a forward direction with respect to a defined direction of rotation of the wheel.

  8. Monitoring-based HVAC Commissioning of an Existing Office Building for Energy Efficiciency

    E-Print Network [OSTI]

    Wang, Liping

    2014-01-01T23:59:59.000Z

    Dascalaki E, Gaglia A. HVAC and indoor thermal conditions inCommissioning of Building HVAC Systems for Improving Energyand diagnosis strategy for HVAC systems involving sensor

  9. Analysis of the HVAC System at the Willow Branch Intermediate School

    E-Print Network [OSTI]

    Wei, G.

    1997-01-01T23:59:59.000Z

    was built in 1983. It was recently expanded in 1994 and renamed the Willow Branch Intermediate School. It now has a total floor area of 88,617 square feet. The system under investigation is a water-loop heat pump system which provides the HVAC needs...

  10. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    Ghajar, Afshin J.

    at Oklahoma State University (www.hvac.okstate.edu) The correct citation for the paper is: Rees, S.J., J cooling loads is of critical concern to designers of HVAC systems. The work reported here has been carried of the HVAC industry worldwide would be improved if common methods of performing key design calculations were

  11. Re-Commissioning of the CAMET HVAC System: A Successful Case Study

    E-Print Network [OSTI]

    Andre, P.; Cuevas, C.; Lacote, P.; Lebrun, J.

    2003-01-01T23:59:59.000Z

    Commissioning is a unique opportunity, for all partners concerned, to learn a lot about the real behavior of a HVAC system. It has to start from comfort and health requirements in occupancy zones, and going back to the plant through the whole air...

  12. System-Level Monitoring and Diagnosis of Building HVAC System

    E-Print Network [OSTI]

    Wu, Siyu

    2013-01-01T23:59:59.000Z

    integrated into building automation systems, particularlyfrom existing building automation systems (BASs) for add-onof modern building automation and control systems, we have

  13. System-Level Monitoring and Diagnosis of Building HVAC System

    E-Print Network [OSTI]

    Wu, Siyu

    2013-01-01T23:59:59.000Z

    695. [50] M. Wetter, Modelica-based modelling and simulationhave been working on Modelica and EnergyPlus simulation59], DOE-2, TRANSYS, Modelica [50], etc. make use of the

  14. Detection and diagnosis of faults and energy monitoring of HVAC systems with least-intrusive power analysis

    E-Print Network [OSTI]

    Luo, Dong, 1966-

    2001-01-01T23:59:59.000Z

    Faults indicate degradation or sudden failure of equipment in a system. Widely existing in heating, ventilating, and air conditioning (HVAC) systems, faults always lead to inefficient energy consumption, undesirable indoor ...

  15. Optimized Fan Control In Variable Air Volume HVAC Systems Using Static Pressure Resets: Strategy Selection and Savings Analysis

    E-Print Network [OSTI]

    Kimla, John

    2010-07-14T23:59:59.000Z

    The potential of static pressure reset (SPR) control to save fan energy in variable air volume HVAC systems has been well documented. Current research has focused on the creation of reset strategies depending on specific system features...

  16. Integrated Ice Storage/Sprinkler HVAC System Sharply Cuts Energy Costs and Air-Distribution First Costs

    E-Print Network [OSTI]

    Meckler, G.

    1986-01-01T23:59:59.000Z

    Integrated ice thermal storage/sprinkler HVAC systems developed and applied by the author in several commercial applications shift a major portion of electric utility demand to cheaper off-peak hours, while also reducing significantly the first cost...

  17. Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage

    E-Print Network [OSTI]

    Mammoli, Andrea

    2014-01-01T23:59:59.000Z

    performance of a solar-thermal- assisted hvac system. Energyfor rows of fixed solar thermal collectors using flatassisted by a 232 m solar thermal array providing heat to a

  18. Comparative guide to emerging diagnostic tools for large commercial HVAC systems

    SciTech Connect (OSTI)

    Friedman, Hannah; Piette, Mary Ann

    2001-05-01T23:59:59.000Z

    This guide compares emerging diagnostic software tools that aid detection and diagnosis of operational problems for large HVAC systems. We have evaluated six tools for use with energy management control system (EMCS) or other monitoring data. The diagnostic tools summarize relevant performance metrics, display plots for manual analysis, and perform automated diagnostic procedures. Our comparative analysis presents nine summary tables with supporting explanatory text and includes sample diagnostic screens for each tool.

  19. IMPLEMENTATION OF A HYBRID CONTROLLER FOR CRITICAL BUILDING HVAC SYSTEMS

    SciTech Connect (OSTI)

    Craig Rieger

    2008-11-01T23:59:59.000Z

    Many industrial facilities utilize pressure control gradients to prevent migration of hazardous species from containment areas to occupied zones, often using Proportional-Integral-Derivative (PID) control systems. When operators rebalance the plant, variation from the desired gradients can occur and the operating conditions can change enough that the PID parameters are no longer adequate to maintain a stable system. As the goal of the ventilation control system is to optimize the pressure gradients and associated flows for the plant, Linear Quadratic Tracking (LQT) is a method that provides a time-based approach to guiding plant interactions. However, LQT methods are susceptible to modeling and measurement errors, and therefore the additional use of soft computing methods is proposed for implementation to account for these errors and nonlinearities. The performance of the resulting hybrid controller is demonstrated through simulation and experimental testing as compared to a representative PID controller.

  20. Life Cycle cost Analysis of Waste Heat Operated Absorption Cooling Systems for Building HVAC Applications

    E-Print Network [OSTI]

    Saravanan, R.; Murugavel, V.

    2010-01-01T23:59:59.000Z

    effect from CO2 emission resulting from the combustion of fossil fuels in utility power plants and the use of chlorofluorocarbon refrigerants, which is currently thought to affect depletion of the ozone layer. The ban on fluorocarbon fluids has been...LIFE CYCLE COST ANALYSIS OF WASTE HEAT OPERATED ABSORPTION COOLING SYSTEMS FOR BUILDING HVAC APPLICATIONS V. Murugavel and R. Saravanan Refrigeration and Air conditioning Laboratory Department of Mechanical Engineering, Anna University...

  1. Building HVAC Requirements Overview Page 4-1 4 Building HVAC Requirements

    E-Print Network [OSTI]

    Building HVAC Requirements ­ Overview Page 4-1 4 Building HVAC Requirements 4.1 Overview 4 conditioning (HVAC) systems. The requirements are presented in this chapter so that it may serve as a single. 2008 Residential Compliance Manual August 2009 #12;Page 4-2 Building HVAC Requirements ­ Overview 4

  2. Proposal for the award of a contract for the design, supply, installation and commissioning of an HVAC (Heating, Ventilation and Air Conditioning) system for Building 3862

    E-Print Network [OSTI]

    2014-01-01T23:59:59.000Z

    Proposal for the award of a contract for the design, supply, installation and commissioning of an HVAC (Heating, Ventilation and Air Conditioning) system for Building 3862

  3. Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel

    E-Print Network [OSTI]

    2012-01-01T23:59:59.000Z

    Proposal for the award of a contract for dismantling, removal and packaging of the existing Heating, Ventilation and Air-Conditioning (HVAC) systems in the PS tunnel

  4. Proposal for the award of a contract for the design, supply, installation and commissioning of Heating, Ventilation and Air-Conditioning (HVAC) systems for the PS accelerator infrastructure

    E-Print Network [OSTI]

    2012-01-01T23:59:59.000Z

    Proposal for the award of a contract for the design, supply, installation and commissioning of Heating, Ventilation and Air-Conditioning (HVAC) systems for the PS accelerator infrastructure

  5. Proposal to negotiate an amendment to an existing contract for the supply and installation of an HVAC system for the HIE-ISOLDE infrastructure

    E-Print Network [OSTI]

    2014-01-01T23:59:59.000Z

    Proposal to negotiate an amendment to an existing contract for the supply and installation of an HVAC system for the HIE-ISOLDE infrastructure

  6. Thermovote: Participatory Sensing for Efficient Building HVAC Conditioning

    E-Print Network [OSTI]

    Cerpa, Alberto E.

    Thermovote: Participatory Sensing for Efficient Building HVAC Conditioning Varick L. Erickson, Measurement, Performance Keywords HVAC conditioning, PMV, thermal comfort, phones 1 Introduction Recently goal, the service that HVAC systems provide is arguably more important than reducing energy. Before we

  7. HVAC, Water Heating, and Appliances Overview - 2015 BTO Peer...

    Office of Environmental Management (EM)

    HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review Research & Development Roadmap: Emerging HVAC Technologies This thermoelastic system provides a promising...

  8. Energy Savings Potential of Flexible and Adaptive HVAC Distribution Systems for Office Buildings

    SciTech Connect (OSTI)

    Loftness, Vivian; Brahme, Rohini; Mondazzi, Michelle; Vineyard, Edward; MacDonald, Michael

    2002-06-01T23:59:59.000Z

    It has been understood by architects and engineers that office buildings with easily re-configurable space and flexible mechanical and electrical systems are able to provide comfort that increases worker productivity while using less energy. Raised floors are an example of how fresh air, thermal conditioning, lighting needs, and network access can be delivered in a flexible manner that is not ''embedded'' within the structure. What are not yet documented is how well these systems perform and how much energy they can save. This area is being investigated in phased projects of the 21st Century Research Program of the Air-conditioning and Refrigeration Technology Institute. For the initial project, research teams at the Center for Building Performance and Diagnostics, Pittsburgh, Pennsylvania, and Oak Ridge National Laboratory, Oak Ridge, Tennessee, documented the diversity, performance, and incidence of flexible and adaptive HVAC systems. Information was gathered worldwide from journal and conference articles, case studies, manufactured products and assemblies, and interviews with design professionals. Their report thoroughly describes the variety of system types along with the various design alternatives observed for plenums, diffusers, individual control, and system integration. Many of the systems are illustrated in the report and the authors provide quantitative and qualitative comparisons. Among conclusions regarding key design issues, and barriers to widespread adoption, the authors state that flexible and adaptive HVAC systems, such as underfloor air, perform as well if not better than ceiling-based systems. Leading engineers have become active proponents after their first experience, which is resulting in these flexible and adaptive HVAC systems approaching 10 percent of the new construction market. To encourage adoption of this technology that improves thermal comfort and indoor air quality, follow-on work is required to further document performance. Architects, professional engineers, and commercial real estate developers will benefit from the availability of information that quantifies energy savings, first cost construction differences, and additional operating costs created when office space must be reconfigured to accommodate new tenants.

  9. Zuo, W. and Chen, Q. 2010 "Simulations of air distribution in buildings by FFD on GPU," HVAC&R Research, 16(6): 785-798.

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    Zuo, W. and Chen, Q. 2010 "Simulations of air distribution in buildings by FFD on GPU," HVAC&R Research, 16(6): 785-798. SIMULATIONS OF AIR DISTRIBUTIONS IN BUILDINGS BY FFD ON GPU Wangda Zuo, Ph to perform real-time simulation for a moderate size building with 107 grids and t = 0.1s using the FFD

  10. COMPREHENSIVE DIAGNOSTIC AND IMPROVEMENT TOOLS FOR HVAC-SYSTEM INSTALLATIONS IN LIGHT COMMERCIAL BUILDINGS

    SciTech Connect (OSTI)

    Abram Conant; Mark Modera; Joe Pira; John Proctor; Mike Gebbie

    2004-10-31T23:59:59.000Z

    Proctor Engineering Group, Ltd. (PEG) and Carrier-Aeroseal LLP performed an investigation of opportunities for improving air conditioning and heating system performance in existing light commercial buildings. Comprehensive diagnostic and improvement tools were created to address equipment performance parameters (including airflow, refrigerant charge, and economizer operation), duct-system performance (including duct leakage, zonal flows and thermal-energy delivery), and combustion appliance safety within these buildings. This investigation, sponsored by the National Energy Technology Laboratory, a division of the U.S. Department of Energy, involved collaboration between PEG and Aeroseal in order to refine three technologies previously developed for the residential market: (1) an aerosol-based duct sealing technology that allows the ducts to be sealed remotely (i.e., without removing the ceiling tiles), (2) a computer-driven diagnostic and improvement-tracking tool for residential duct installations, and (3) an integrated diagnosis verification and customer satisfaction system utilizing a combined computer/human expert system for HVAC performance. Prior to this work the aerosol-sealing technology was virtually untested in the light commercial sector--mostly because the savings potential and practicality of this or any other type of duct sealing had not been documented. Based upon the field experiences of PEG and Aeroseal, the overall product was tailored to suit the skill sets of typical HVAC-contractor personnel.

  11. The Effect of Optimal Tuning of the Heating/Cooling Curve in AHU of HVAC System in Real Practice

    E-Print Network [OSTI]

    2004-01-01T23:59:59.000Z

    Paper 81, ICEBO 2004 TNO Bouw, The Netherlands Page: 1 of 12 THE EFFECT OF OPTIMAL TUNING OF THE HEATING-/ COOLING CURVE IN AHU OF HVAC SYSTEM IN REAL PRACTISE P.A. (Bert) Elkhuizen(1), J.E. (Jan Ewout) Scholten(1), H.C. (Henk) Peitsman(1... to the settings of the heating/ cooling curve in the central Air Handling Unit?s (AHU?s) of HVAC systems without loss of comfort. In most cases the number of complaints will also be reduced. The method can be used in both new and existing buildings...

  12. The Effect of Optimal Tuning of the Heating/Cooling Curve in AHU of HVAC System in Real Practice 

    E-Print Network [OSTI]

    2004-01-01T23:59:59.000Z

    Paper 81, ICEBO 2004 TNO Bouw, The Netherlands Page: 1 of 12 THE EFFECT OF OPTIMAL TUNING OF THE HEATING-/ COOLING CURVE IN AHU OF HVAC SYSTEM IN REAL PRACTISE P.A. (Bert) Elkhuizen(1), J.E. (Jan Ewout) Scholten(1), H.C. (Henk) Peitsman(1... to the settings of the heating/ cooling curve in the central Air Handling Unit?s (AHU?s) of HVAC systems without loss of comfort. In most cases the number of complaints will also be reduced. The method can be used in both new and existing buildings...

  13. Model-Based Hierarchical Optimal Control Design for HVAC Systems

    E-Print Network [OSTI]

    Maasoumy, Mehdi; Pinto, Alessandro; Sangiovanni-Vincentelli, Alberto

    2014-01-01T23:59:59.000Z

    Re- frigerating, and Air-Conditioning Engineers, 1989. [16]ventilating, and air conditioning system with thermal loadand cooling loads in air conditioning practice. The walls

  14. VOLUME 11, NUMBER 2 HVAC&R RESEARCH APRIL 2005 Ground-Source Heat Pump System Research--

    E-Print Network [OSTI]

    VOLUME 11, NUMBER 2 HVAC&R RESEARCH APRIL 2005 165 EDITORIAL Ground-Source Heat Pump System Research-- Past, Present, and Future J.D. Spitler, PhD, PE Fellow ASHRAE Ground-source heat pump (GSHP-source heat pumps installed worldwide. These systems may be closed-loop ("ground-coupled") or open

  15. Analysis of Innovative HVAC System Technologies and Their Application for Office Buildings in Hot and Humid Climates

    E-Print Network [OSTI]

    Tanskyi, Oleksandr

    2012-02-14T23:59:59.000Z

    air distribution system VAV ? Variable air volume VFD ? Variable frequency drive wb ? wet-bulb WERC ? Wisenbaker Engineering Research Center viii TABLE OF CONTENTS Page ABSTRACT... fulfillment of the requirements for the degree of MASTER OF SCIENCE December 2010 Major Subject: Mechanical Engineering Analysis of Innovative HVAC System Technologies and Their Application for Office...

  16. Case Study of an Innovative HVAC System with Integral Dehumidifier

    E-Print Network [OSTI]

    Shirey, D. B.; Raustad, R. A.

    and humidistat. The dehumidification element of the system is completely independent from the air conditioner and works nearly the same as conventional dehumidification equipment. At times, both the dehumidification equipment and the air conditioner operate...

  17. Comparison of emerging diagnostic tools for large commercial HVAC systems

    SciTech Connect (OSTI)

    Friedman, Hannah; Piette, Mary Ann

    2001-04-06T23:59:59.000Z

    Diagnostic software tools for large commercial buildings are being developed to help detect and diagnose energy and other performance problems with building operations. These software applications utilize energy management control system (EMCS) trend log data. Due to the recent development of diagnostic tools, there has been little detailed comparison among the tools and a limited awareness of tool capabilities by potential users. Today, these diagnostic tools focus mainly on air handlers, but the opportunity exists for broadening the scope of the tools to include all major parts of heating, cooling, and ventilation systems in more detail. This paper compares several tools in the following areas: (1) Scope, intent, and background; (2) Data acquisition, pre-processing, and management; (3) Problems detected; (4) Raw data visualization; (5) Manual and automated diagnostic methods and (6) Level of automation. This comparison is intended to provide practitioners and researchers with a picture of the current state of diagnostic tools. There is tremendous potential for these tools to help improve commercial building energy and non-energy performance.

  18. Value impact analysis of Generic Issue 143, Availability of Heating, Ventilation, Air Conditioning (HVAC) and Chilled Water Systems

    SciTech Connect (OSTI)

    Daling, P.M.; Marler, J.E.; Vo, T.V.; Phan, H.; Friley, J.R. [Pacific Northwest Lab., Richland, WA (United States)

    1993-11-01T23:59:59.000Z

    This study evaluates the values (benefits) and impacts (costs) associated with potential resolutions to Generic Issue 143, ``Availability of HVAC and Chilled Water Systems.`` The study identifies vulnerabilities related to failures of HVAC, chilled water, and room cooling systems; develops estimates of room heatup rates and safety-related equipment vulnerabilities following losses of HVAC/room cooler systems; develops estimates of the core damage frequencies and public risks associated with failures of these systems; develops three proposed resolution strategies to this generic issue; and performs a value/impact analysis of the proposed resolutions. Existing probabilistic risk assessments for four representative plants, including one plant from each vendor, form the basis for the core damage frequency and public risk calculations. Both internal and external events were considered. It was concluded that all three proposed resolution strategies exceed the $1,000/person-rem cost-effectiveness ratio. Additional evaluations were performed to develop ``generic`` insights on potential design-related and configuration-related vulnerabilities and potential high-frequency ({approximately}1E-04/RY) accident sequences that involve failures of HVAC/room cooling functions. It was concluded that, although high-frequency accident sequences may exist at some plants, these high-frequency sequences are plant-specific in nature or have been resolved through hardware and/or operational changes. The plant-specific Individual Plant Examinations are an effective vehicle for identification and resolution of these plant-specific anomalies and hardware configurations.

  19. Feasibility of Retrofitting Centralized HVAC Systems for Room-Level Zoning Tamim Sookoor, Brian Holben, Kamin Whitehouse

    E-Print Network [OSTI]

    Whitehouse, Kamin

    and enable rooms to be heated or cooled individually, in order to reduce waste caused by conditioning into each room. Such a system could reduce wasted energy that is used to heat and cool unoccupied rooms {sookoor,bnh4k,whitehouse}@cs.virginia.edu Abstract--Heating, ventilation, and cooling (HVAC) accounts

  20. Proper Setup of HVAC System in Conjunction with Sound Building 'Skin' Design for Alleviation of IAQ and Energy Performance Problems

    E-Print Network [OSTI]

    Rosenberg, M.

    2006-01-01T23:59:59.000Z

    climates, not only because of the loss of energy, but also because of damage that can result to insulation, drywall, and structure in addition to promotion of mold and mildew growth. Proper setup of the HVAC system, in conjunction with sound building “skin...

  1. 2013 Energy Code Changes That Effect the HVAC

    E-Print Network [OSTI]

    California at Davis, University of

    2013 Energy Code Changes That Effect the HVAC Industry Tav Commins Mechanical Engineer California Energy Commission #12;HVAC Mandatory Measures For All Newly Installed Residential HVAC Systems (New tons provided by air cooled chillers #12;Non Residential HVAC Measures Cooling Towers greater than 150

  2. Strategy Guideline: HVAC Equipment Sizing

    SciTech Connect (OSTI)

    Burdick, A.

    2012-02-01T23:59:59.000Z

    The heating, ventilation, and air conditioning (HVAC) system is arguably the most complex system installed in a house and is a substantial component of the total house energy use. A right-sized HVAC system will provide the desired occupant comfort and will run efficiently. This Strategy Guideline discusses the information needed to initially select the equipment for a properly designed HVAC system. Right-sizing of an HVAC system involves the selection of equipment and the design of the air distribution system to meet the accurate predicted heating and cooling loads of the house. Right-sizing the HVAC system begins with an accurate understanding of the heating and cooling loads on a space; however, a full HVAC design involves more than just the load estimate calculation - the load calculation is the first step of the iterative HVAC design procedure. This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

  3. DEMONSTRATION OF A HYBRID INTELLIGENT CONTROL STRATEGY FOR CRITICAL BUILDING HVAC SYSTEMS

    SciTech Connect (OSTI)

    Craig Rieger; D. Subbaram Naidu

    2010-06-01T23:59:59.000Z

    Many industrial facilities utilize pressure control gradients to prevent migration of hazardous species from containment areas to occupied zones, often using Proportional-Integral-Derivative (PID) control. Within these facilities, PID control is often inadequate to maintain desired performance due to changing operating conditions. As the goal of the Heating, Ventilation and Air-Conditioning (HVAC) control system is to optimize the pressure gradients and associated flows for the plant, Linear Quadratic Tracking (LQT) provides a time-based approach to guiding plant interactions. However, LQT methods are susceptible to modeling and measurement errors, and therefore a hybrid design using the integration of soft control methods with hard control methods is developed and demonstrated to account for these errors and nonlinearities.

  4. Hvac systems as a tool in controlling indoor air quality: A literature review. Final report, May-August 1993

    SciTech Connect (OSTI)

    Samfield, M.M.

    1995-12-01T23:59:59.000Z

    The report gives results of a review of literature on the use of heating, ventilation, and air-conditioning (HVAC) systems to control indoor air quality (IAQ). One conclusion of the review is that HVAC systems very often contribute to the indoor air pollution because of (1) poor system maintenance, (2) overcrowding or the introduction of new pollution-generating sources with buildings, and (3) the location of outdoor air near ambient pollution sources. Another conclusion is that failure to trade off between energy conservation and employee productivity may result in increased IAQ problems. The report contents are based on literature survey covering the years 1988 through 1993, involving 60 references, 32 of which are cited in the report.

  5. Report on HVAC option selections for a relocatable classroom energy and indoor environmental quality field study

    E-Print Network [OSTI]

    2001-01-01T23:59:59.000Z

    LBNL- 49026 Report on HVAC Option Selections for aTable 3. High performance HVAC system filter selectionDrop ("H 2 O) Appendix A – RC HVAC working drawings. Figure

  6. Distributed scheduling for efficient HVAC precooling operations

    E-Print Network [OSTI]

    Yang, Su

    2014-01-01T23:59:59.000Z

    heating, ventilating and air conditioning. Springer, J. W.ventilation and air conditioning in buildings. Wiley, 2012.Ventilation and Air Conditioning (HVAC) systems’ in-building

  7. Module Development and Simulation of the Variable Refrigerant Flow Air Conditioning System under Cooling Conditions in Energyplus

    E-Print Network [OSTI]

    Zhou, Y.; Wu, J.; Wang, R.; Shiochi, S.

    2006-01-01T23:59:59.000Z

    ICEBO2006, Shenzhen, China HVAC Technologies for Energy Efficiency Vol.IV-1-2 Module Development and Simulation of the Variable Refrigerant Flow Air Conditioning System under Cooling Conditions in Energyplus Yanping Zhou Jingyi..., especially for those who ICEBO2006, Shenzhen, China HVAC Technologies for Energy Efficiency Vol.IV-1-2 show some interest about high-efficiency systems like VRF, it becomes of interest to compare the VRF to other systems and evaluate VRF?s performance...

  8. Indirect Benefits (Increased Roof Life and HVAC Savings) from...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Indirect Benefits (Increased Roof Life and HVAC Savings) from a Solar PV System at the San Jos Convention Center Indirect Benefits (Increased Roof Life and HVAC Savings) from a...

  9. HVAC Program

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField8,Dist.NewofGeothermal848 Unlimited Release1/2 HR 1.00 $ ForHVAC

  10. Energy Savings Potential and RD&D Opportunities for Commercial Building HVAC Systems

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny:RevisedAdvisoryStandard |inHVAC | Department of Energy HVAC EnergyCommercial

  11. Duty-Cycling Buildings Aggressively: The Next Frontier in HVAC Control

    E-Print Network [OSTI]

    Simunic, Tajana

    Duty-Cycling Buildings Aggressively: The Next Frontier in HVAC Control Yuvraj Agarwal, Bharathan the dominant energy consumer is the HVAC system. Despite this fact, in most buildings the HVAC system is run sensing to guide the operation of a building HVAC system. We show how we can enable aggressive duty

  12. Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1

    E-Print Network [OSTI]

    Johnson, F.X.

    2010-01-01T23:59:59.000Z

    Efficiency Choice 6.3 New Home HVAC System Choice 6.4. NewJuly. EPRI. 1990. REEPS 2.0 HVAC Model Logic, prepared by1990. Review of Equipment HVAC Choice Parameters. Cambridge

  13. Deposition of Biological Aerosols on HVAC Heat Exchangers

    E-Print Network [OSTI]

    LBNL-47669 Deposition of Biological Aerosols on HVAC Heat Exchangers Jeffrey Siegel and Iain Walker of Biological Aerosols on HVAC Heat Exchangers Jeffrey A. Siegel Iain S. Walker, Ph.D. ASHRAE Student Member that are found in commercial and residential HVAC systems of 1 - 6 m/s (200 - 1200 ft/min), particle diameters

  14. MATERIALS AND INFORMATION FLOWS FOR HVAC DUCTWORK FABRICATION AND SITE

    E-Print Network [OSTI]

    Tommelein, Iris D.

    MATERIALS AND INFORMATION FLOWS FOR HVAC DUCTWORK FABRICATION AND SITE INSTALLATION Matt Holzemer,1, and air-conditioning (HVAC) systems requires a set of complex activities and handoffs between multiple architecture-, engineering-, and construction practitioners. This paper highlights one part of the HVAC

  15. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    Ghajar, Afshin J.

    of system energy consumption and electrical demand in hourly or shorter time intervals. The development, and environmental friendli- ness make them a viable alternative for residential and commercial HVAC systems. Ground and improvements in load profiles. However, despite the perceived economic benefits of such systems, there has been

  16. Comparisons of HVAC Simulations between EnergyPlus and DOE-2.2 for Data Centers

    E-Print Network [OSTI]

    Hong, Tianzhen

    2009-01-01T23:59:59.000Z

    cooling systems with and without water economizer Variable air volume systems Multiple CRAC units for the data center

  17. Measurement of HVAC system performance and local ventilation using passive perfluorocarbon tracer technology

    SciTech Connect (OSTI)

    Dietz, R.N.; Goodrich, R.W.

    1995-06-01T23:59:59.000Z

    In April of 1993, two (2) perfluorocarbon tracer (PFT) ventilation/indoor air quality assessment tests were performed in the Gleeson Hall building of the SUNY Farmingdale campus. The building was being modified, in part, as a result of significant occupant complaints of perceived poor air quality. The four story building had a basement first floor with air supplied normally by an HVAC system labelled as AC1. During this study, AC1 was inoperational and the basement interior rooms (walls) were primarily gone; the other three floors were still being used for classes. It is possible that a sense of poor air quality may have been perceived by first-floor occupants because they were working in the basement, but this issue could not be addressed. The second floor had two (2) lecture halls--Rm 202 (handled by AC4) and Rm 204 (handled by AC5); the balance of the second floor interior rooms and corridors was split between two other air handling systems, AC2 for the west side of the building and AC3 for the east side. The remaining 3rd and 4th floors were also split about evenly between AC2 and AC3. The perimeter rooms, equipped with wall units having their own outside air (OA) source plus centralized return air (RA) bypasses, were not included in this testing which was restricted to the basement floor (1st floor) and the four operating air handling systems, AC2 to AC5, during Test 1 and only AC2 to AC5 during Test 2. Two types of tests were performed using the full suite of 5 PFT types available. The first test was designed to measure the infiltration, exfiltration, and air exchange between the 5 AC zones above and the second test used the 5th tracer, which had been in the basement, as a distributed source throughout the four other zones to act as a surrogate pollutant source. This report provides final conclusions of both tests and suggestions regarding its usefulness in similar building ventilation and indoor air quality assessments.

  18. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (http://www.hvac.okstate.edu).

    E-Print Network [OSTI]

    at Oklahoma State University (http://www.hvac.okstate.edu). The correct citation for the paper is: Spitler, J.D. 2007. Research Planning for the HVAC&R Industry. HVAC&R Research 13(5):681- 682. #12;VOLUME 13, NUMBER 5 HVAC&R RESEARCH SEPTEMBER 2007 681 EDITORIAL Research Planning for the HVAC&R Industry Jeffrey D

  19. NREL's Advanced Thermal Conversion Laboratory at the Center for Buildings and Thermal Systems: On the Cutting-Edge of HVAC and CHP Technology (Revised)

    SciTech Connect (OSTI)

    Not Available

    2005-09-01T23:59:59.000Z

    This brochure describes how the unique testing capabilities of NREL's Advanced Thermal Conversion Laboratory at the Center For Buildings and Thermal Systems can help industry meet the challenge of developing the next generation of heating, ventilating, and air-conditioning (HVAC) and combined heat and power (CHP) equipment and concepts.

  20. Variable Refrigerant Flow HVAC

    E-Print Network [OSTI]

    Jones, S.

    2013-01-01T23:59:59.000Z

    heat pump utilizing VFD Inverter Compressors and LEV’s Unlike conventional commercial and residential HVAC systems in the USA The predominate method of cooling and heating in the world ESL-KT-13-12-33 CATEE 2013: Clean Air Through Energy Efficiency... Conference, San Antonio, Texas Dec. 16-18 Heat Pump operation at lower ambient conditions -13 -4 5 17 23 32 41 470 0.2 0.4 0.6 0.8 1 1.2 Residential Heating Capacity at Low Temperatures MUZ-FE18NA MUZ-FE09NA MUZ-FE12NA Unitary Outdoor Temperature (F...

  1. Comparison of heating and cooling energy consumption by HVAC system with mixing and displacement air distribution for a restaurant dining area in different climates

    SciTech Connect (OSTI)

    Zhivov, A.M. [International Air Technologies, Inc., Savoy, IL (United States); Rymkevich, A.A. [St. Petersburg Academy of Refrigeration and Food Technology (Russian Federation). Dept. of Refrigeration Machines and Air-Conditioning Systems

    1998-12-31T23:59:59.000Z

    Different ventilation strategies to improve indoor air quality and to reduce HVAC system operating costs in a restaurant with nonsmoking and smoking areas and a bar are discussed in this paper. A generic sitting-type restaurant is used for the analysis. Prototype designs for the restaurant chain with more than 200 restaurants in different US climates were analyzed to collect the information on building envelope, dining area size, heat and contaminant sources and loads, occupancy rates, and current design practices. Four constant air volume HVAC systems wit h a constant and variable (demand-based) outdoor airflow rate, with a mixing and displacement air distribution, were compared in five representative US climates: cold (Minneapolis, MN); Maritime (Seattle, WA); moderate (Albuquerque, NM); hot-dry (Phoenix, AZ); and hot-humid (Miami, FL). For all four compared cases and climatic conditions, heating and cooling consumption by the HVAC system throughout the year-round operation was calculated and operation costs were compared. The analysis shows: Displacement air distribution allows for better indoor air quality in the breathing zone at the same outdoor air supply airflow rate due to contaminant stratification along the room height. The increase in outdoor air supply during the peak hours in Miami and Albuquerque results in an increase of both heating and cooling energy consumption. In other climates, the increase in outdoor air supply results in reduced cooling energy consumption. For the Phoenix, Minneapolis, and Seattle locations, the HVAC system operation with a variable outdoor air supply allows for a decrease in cooling consumption up to 50% and, in some cases, eliminates the use of refrigeration machines. The effect of temperature stratification on HVAC system parameters is the same for all locations; displacement ventilation systems result in decreased cooling energy consumption but increased heating consumption.

  2. Assessment of organic compound exposures, thermal comfort parameters, and HVAC system-driven air exchange rates in public school portable classrooms in California

    E-Print Network [OSTI]

    Shendell, Derek Garth

    2010-01-01T23:59:59.000Z

    SPECIFY UNITS) when heat (of HVAC) is turned off?using the heat (from HVAC)? A. B. C. D. January Februaryair conditionmg (from HVAC)? A. B. C. D. January February

  3. Air-Side Energy Use Calculations for Four HVAC Systems: Dual Duct Constant Volume (DDCAV), Dual Duct Variable Volume (DDVAV), Constant Volume with Reheat (CAVRH0), Variable Volume with Reheat (VAVRH)

    E-Print Network [OSTI]

    Haberl, J. S.

    2001-01-01T23:59:59.000Z

    This report contains engineering calculations for four (4) air-side, heating, ventilating and air-conditioning systems (HVAC) systems, including: dual duct constant volume (DDCAV), dual duct variable volume (DDVAV), constant volume with reheat...

  4. CALIFORNIA ENERGY Large HVAC Building

    E-Print Network [OSTI]

    CALIFORNIA ENERGY COMMISSION Large HVAC Building Survey Information Database of Buildings over 100 Energy Systems: Productivity and Building Science Program. This program was funded by the California of Portland Energy Conservation, Inc. Project Management: Cathy Higgins, Program Director for New Buildings

  5. Thermal Modeling for a HVAC Controlled Real-life Yong Fu1, Mo Sha1, Chengjie Wu1, Andrew Kutta1, Anna Leavey2, Chenyang Lu1,

    E-Print Network [OSTI]

    Lu, Chenyang

    consumption in build- ings is heating, ventilation, and air conditioning (HVAC). For an HVAC system to provide of energy consumption in buildings is heating, ventilation, and air conditioning (HVAC), accounting for 33

  6. Distributed Control of HVAC&R Networks

    E-Print Network [OSTI]

    Elliott, Matthew Stuart

    2013-07-05T23:59:59.000Z

    retains a degree of modularity—changing one component does not require changing all controllers. The final contribution is a new distributed optimization algorithm that is rooted in distributed MPC and is especially motivated by HVAC&R systems...

  7. FAULT DETECTION IN HVAC SYSTEMS USING MODEL-BASED FEEDFORWARD CONTROL

    E-Print Network [OSTI]

    Diamond, Richard

    building, greater energy consumption, and increased wear on controlled elements, such as actuators, valves Laboratory 507 E Michigan Street 1 Cyclotron Road Milwaukee, WI 53201, USA Berkeley, California 94720, USA, Comfort/Energy, Control/Simulation/Field Tests, Air-Conditioning Systems, Feedforward Control, Diagnostics

  8. HVAC Maintenance and Technologies

    Broader source: Energy.gov [DOE]

    Presentation covers the HVAC maintenance and technologies, and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Providence, Rhode Island.

  9. Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

    E-Print Network [OSTI]

    2012-01-01T23:59:59.000Z

    Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

  10. Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating Ventilation and Air Conditioning (HVAC) system for the HIE-ISOLDE infrastructure

    E-Print Network [OSTI]

    2012-01-01T23:59:59.000Z

    Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating Ventilation and Air Conditioning (HVAC) system for the HIE-ISOLDE infrastructure

  11. STANDARD DATA FILES FOR COMPUTER THERMAL SIMULATION

    E-Print Network [OSTI]

    Amor, Robert

    University Box 600 Wellington November 2003 REPORT PREPARED AS PART OF RESEARCH CONTRACT WITH MARKET Project Objective 1 The Building Simulation Programs 2 HVAC Systems (2); Location of Spaces (2) Building Gains A-II-7 HVAC Regime A-II-16 Building Dimensions A-II-19 APPENDIX III WEATHER PROCESSING A-III-1

  12. Flexibility of Commercial Building HVAC Fan as Ancillary Service for Smart Grid

    E-Print Network [OSTI]

    Maasoumy, Mehdi

    2013-01-01T23:59:59.000Z

    Efficient Building Control Systems, Smart Grid and AircraftCommercial Building HVAC Fan as Ancillary Service for Smart

  13. Building and Environment 42 (2007) 203217 Model-based analysis and simulation of airflow control systems of

    E-Print Network [OSTI]

    Melnik, Roderick

    2007-01-01T23:59:59.000Z

    , testing, operation, and management of heating, ventilation and air conditioning (HVAC) systems rely systems of ventilation units in building environments Zhuang Wua , Roderick V.N. Melnikb,Ã, Finn Borupc and simulation of the airflow control system of ventilation units is of primary importance for the design

  14. Field Evaluation of Desiccant-Integrated HVAC Systems: A Review of Case Studies in Multiple Commercial/Institutional Building Types

    E-Print Network [OSTI]

    Yborra, S. C.

    1998-01-01T23:59:59.000Z

    An independent field research effort co-funded by the Gas Research Institute and The U.S. Department of Energy (DOE) Oak Ridge National Laboratory is documenting the performance and energy usage characteristics of active desiccant-integrated HVAC...

  15. Occupancy Based Demand Response HVAC Control Strategy Varick L. Erickson

    E-Print Network [OSTI]

    Cerpa, Alberto E.

    Occupancy Based Demand Response HVAC Control Strategy Varick L. Erickson University of California an efficient demand response HVAC control strategy, actual room usage must be considered. Temperature and CO2 are used for simulations but not for predictive demand response strategies. In this paper, we develop

  16. TITLE: HVAC TESTING & BALANCING FOR MAJOR AND MINOR PROJECTS OBJECTIVE AND

    E-Print Network [OSTI]

    Fernandez, Eduardo

    TITLE: HVAC TESTING & BALANCING FOR MAJOR AND MINOR PROJECTS OBJECTIVE AND PURPOSE: To provide an independent test & balance for the adjustment of all HVAC systems in all major projects and minor projects

  17. Department of Energy and Mineral Engineering Spring 2013 Solar Innovations -HVAC and Waste Stream Analysis

    E-Print Network [OSTI]

    Demirel, Melik C.

    PENNSTATE Department of Energy and Mineral Engineering Spring 2013 Solar Innovations - HVAC and Waste Stream Analysis Overview There are two problems that were voiced by Solar Innovations, HVAC system design and recycling stream improvement. The HVAC system was not providing even conditioning of office

  18. VOLUME 11, NUMBER 2 HVAC&R RESEARCH APRIL 2005 An Optimization-Based Approach for

    E-Print Network [OSTI]

    Luh, Peter

    VOLUME 11, NUMBER 2 HVAC&R RESEARCH APRIL 2005 215 An Optimization-Based Approach for Facility formulation and the correspond- ing solution methodology for HVAC systems. The problem is to minimize the energy and demand costs through control of HVAC units while satisfying human comfort, system dynamics

  19. Origins of Analysis Methods in Energy Simulation Programs Used for High Performance Commercial Buildings

    E-Print Network [OSTI]

    Oh, Sukjoon

    2013-08-19T23:59:59.000Z

    Current designs of high performance buildings utilize hourly building energy simulations of complex, interacting systems. Such simulations need to quantify the benefits of numerous features including: thermal mass, HVAC systems and, in some cases...

  20. Modeling Building Thermal Response to HVAC Zoning Virginia Smith

    E-Print Network [OSTI]

    Whitehouse, Kamin

    . Much of this wasted energy is used to heat or cool unoccupied spaces during long periods when people HVAC systems account for 38% of building energy usage. Studies have indicated at least 5-15% waste due to unoccu- pied spaces being conditioned. Our goal is to minimize this waste by retrofitting HVAC systems

  1. Methodology to Analyze the Sensitivity of Building Energy Consumption to HVAC System Sensor Error

    E-Print Network [OSTI]

    Ma, Liang

    2012-02-14T23:59:59.000Z

    parameters. There are a total of eight scenarios considered in this simulation. The simulation tool was developed based on Excel. The control parameters examined include room temperature, cold deck temperature, hot deck temperature, pump pressure, and fan...

  2. HVAC Installed Performance

    Broader source: Energy.gov [DOE]

    This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question HVAC proper installation energy savings: over-promising or under-delivering?"

  3. VOLUME 16, NUMBER 3 HVAC&R RESEARCH MAY 2010 The Effects of Filtration on

    E-Print Network [OSTI]

    Siegel, Jeffrey

    VOLUME 16, NUMBER 3 HVAC&R RESEARCH MAY 2010 273 The Effects of Filtration on Pressure Drop and Energy Consumption in Residential HVAC Systems (RP-1299) Brent Stephens Atila Novoselac, PhD Jeffrey A of high-efficiency HVAC filters is a common strategy to control exposure to airborne particulate matter

  4. Sentinel: Occupancy Based HVAC Actuation using Existing WiFi Infrastructure within Commercial Buildings

    E-Print Network [OSTI]

    Gupta, Rajesh

    Sentinel: Occupancy Based HVAC Actuation using Existing WiFi Infrastructure within Commercial.agarwal@cs.cmu.edu ABSTRACT Commercial buildings contribute to 19% of the primary energy consumption in the US, with HVAC systems accounting for 39.6% of this usage. To reduce HVAC energy use, prior studies have pro- posed using

  5. Multi-carrier Signal Transmission through HVAC Ducts: Experimental Results for Channel Capacity

    E-Print Network [OSTI]

    Stancil, Daniel D.

    Multi-carrier Signal Transmission through HVAC Ducts: Experimental Results for Channel Capacity, for the first time, experimental results on channel capacity of heating, ventilation, and air-conditioning (HVAC through a building HVAC duct system demonstrate the ability to transmit with a spectral efficiency of 3

  6. Wireless Infrastructure for Performing Monitoring, Diagnostics, and Control HVAC and Other Energy-Using Systems in Small Commercial Buildings

    SciTech Connect (OSTI)

    Patrick O'Neill

    2009-06-30T23:59:59.000Z

    This project focused on developing a low-cost wireless infrastructure for monitoring, diagnosing, and controlling building systems and equipment. End users receive information via the Internet and need only a web browser and Internet connection. The system used wireless communications for: (1) collecting data centrally on site from many wireless sensors installed on building equipment, (2) transmitting control signals to actuators and (3) transmitting data to an offsite network operations center where it is processed and made available to clients on the Web (see Figure 1). Although this wireless infrastructure can be applied to any building system, it was tested on two representative applications: (1) monitoring and diagnostics for packaged rooftop HVAC units used widely on small commercial buildings and (2) continuous diagnosis and control of scheduling errors such as lights and equipment left on during unoccupied hours. This project developed a generic infrastructure for performance monitoring, diagnostics, and control, applicable to a broad range of building systems and equipment, but targeted specifically to small to medium commercial buildings (an underserved market segment). The proposed solution is based on two wireless technologies. The first, wireless telemetry, is used for cell phones and paging and is reliable and widely available. This risk proved to be easily managed during the project. The second technology is on-site wireless communication for acquiring data from sensors and transmitting control signals. The technology must enable communication with many nodes, overcome physical obstructions, operate in environments with other electrical equipment, support operation with on-board power (instead of line power) for some applications, operate at low transmission power in license-free radio bands, and be low cost. We proposed wireless mesh networking to meet these needs. This technology is relatively new and has been applied only in research and tests. This proved to be a major challenge for the project and was ultimately abandoned in favor of a directly wired solution for collecting sensor data at the building. The primary reason for this was the relatively short ranges at which we were able to effectively place the sensor nodes from the central receiving unit. Several different mesh technologies were attempted with similar results. Two hardware devices were created during the original performance period of the project. The first device, the WEB-MC, is a master control unit that has two radios, a CPU, memory, and serves as the central communications device for the WEB-MC System (Currently called the 'BEST Wireless HVAC Maintenance System' as a tentative commercial product name). The WEB-MC communicates with the local mesh network system via one of its antennas. Communication with the mesh network enables the WEB-MC to configure the network, send/receive data from individual motes, and serves as the primary mechanism for collecting sensor data at remote locations. The second antenna enables the WEB-MC to connect to a cellular network ('Long-Haul Communications') to transfer data to and from the NorthWrite Network Operations Center (NOC). A third 'all-in-one' hardware solution was created after the project was extended (Phase 2) and additional resources were provided. The project team leveraged a project funded by the State of Washington to develop a hardware solution that integrated the functionality of the original two devices. The primary reason for this approach was to eliminate the mesh network technical difficulties that severely limited the functionality of the original hardware approach. There were five separate software developments required to deliver the functionality needed for this project. These include the Data Server (or Network Operations Center), Web Application, Diagnostic Software, WEB-MC Embedded Software, Mote Embedded Software. Each of these developments was necessarily dependent on the others. This resulted in a challenging management task - requiring high bandwidth communications among

  7. WEATHER SEQUENCES FOR PREDICTING HVAC SYSTEM BEHAVIOUR IN RESIDENTIAL UNITS LOCATED IN TROPICAL CLIMATES.

    E-Print Network [OSTI]

    Boyer, Edmond

    . The sensations of thermal discomfort in these buildings have increased the energy consumption by the use. This development needs precise information about the effect of climate patterns on buildings. For energy find three types of database for the energy buildings simulations: - Simulations can be made by using

  8. Co-design of Control Algorithm and Embedded Platformfor Building HVAC Systems

    E-Print Network [OSTI]

    Maasoumy, Mehdi; Zhu, Qi; Li, Cheng; Meggers, Forrest; Sangiovanni-Vincentelli, Alberto

    2013-01-01T23:59:59.000Z

    as part of a Building Automation System (BAS). The task of aflow for building automation and control systems,” in Real-of building automation and control systems,” Design Test of

  9. Post-Retrocommissioning HVAC Operations Monitoring Using Enterprise-Wide energy Management System

    E-Print Network [OSTI]

    Amarnani, N.; Roberts, B.; Choy, H.

    2007-01-01T23:59:59.000Z

    components/systems to diagnose and resolve root causes of operational deficiencies. During the implementation phase, new energy efficiency measures were installed, sequence of operations were optimized and functionally tested. System-level benchmark models...

  10. Total Quality Commissioning for HVAC Systems to Assure High Performance Throughout the Whole Life Cycle

    E-Print Network [OSTI]

    Maisey, G.; Milestone, B.

    2005-01-01T23:59:59.000Z

    popular systems. Although first costs can sometimes be greater, they can be designed to be highly flexible and adaptable, not to mention efficient and long lived. Systems employing earth or geothermal conditions can provide increased efficiency.... FIGURE 12 – GEOTHERMAL SYSTEM WITH ROTARY WHEEL – Although the geothermal portion of this system is highly advisable, the rotary wheel is not. The rotary wheel does not perform well for very long and has an average useful life cycle of six years...

  11. Air-Side Energy Use Calculations for Four HVAC Systems: Dual Duct Constant Volume (DDCAV), Dual Duct Variable Volume (DDVAV), Constant Volume with Reheat (CAVRH), Variable Volume with Reheat (VAVRH), Four Pipe Fan Coil Unit (FC), Four Pipe Induction Unit (FI), and Single Zone (SZ) Systems, Revised June 2002

    E-Print Network [OSTI]

    Haberl, J. S.; Bou-Saada, T. E.; Saman, N. F.

    2001-01-01T23:59:59.000Z

    This report contains engineering calculations for seven (7) air-side, heating, ventilating and air conditioning systems (HVAC) systems, including: dual duct constant volume (DDCAV), dual duct variable volume (DDVAV), constant volume with reheat...

  12. Using Simulation Models for Building Commissioning

    E-Print Network [OSTI]

    Claridge, D. E.

    2004-01-01T23:59:59.000Z

    , Sweden. This building utilizes multiple innovative HVAC systems. They used the IDA simulation environment to assess these untested HVAC-solutions and for dimensioning. During the initial commissioning they evaluated the performance using extensive... D2 is titled Use of Whole Building Simulation in Commissioning. Regular participants of the subtask meetings have included Oliver Baumann (Germany), David Claridge, Chair (USA), Jorgen Eriksson (Sweden), Nestor Fonseca, Johnny Holst (Norway), Per...

  13. Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Massieh Najafi1

    E-Print Network [OSTI]

    . of Statistics, U. of California Berkeley, bartlett@cs.berkeley.edu 4 Leader, Commercial Building Systems Group of five to fifteen percent are achievable in commercial buildings by detecting and correcting building;1. Introduction A commercial building's various energy systems creep from their original design goals

  14. Co-design of Control Algorithm and Embedded Platformfor Building HVAC Systems

    E-Print Network [OSTI]

    Maasoumy, Mehdi; Zhu, Qi; Li, Cheng; Meggers, Forrest; Sangiovanni-Vincentelli, Alberto

    2013-01-01T23:59:59.000Z

    Co-design of Control Algorithm and Embedded Platform foroptimal systems. We propose a co-design approach that an-mod- els, we explore the co-design of the control algorithm

  15. Analysis of a hybrid UFAD and radiant hydronic slab HVAC system

    E-Print Network [OSTI]

    Raftery, Paul; Lee, Kwang Ho; Webster, Thomas; Bauman, Fred

    2011-01-01T23:59:59.000Z

    speed, and the cooling tower supply water temperature set-operates in ‘free-cooling’ mode to supply cool water to thealso include a cooling system that can supply cool water to

  16. Analysis of the Design of an HVAC System in a Public Building

    E-Print Network [OSTI]

    Wei, P.; Shao, Z.; Chen, H.

    2006-01-01T23:59:59.000Z

    . The optimized combination of these three systems is carried out in this building to meet the demand on comfort, energy conservation, and fire control and protection, which can provide a reference for the design of similar buildings....

  17. Classroom HVAC: Improving ventilation and saving energy -- field study plan

    SciTech Connect (OSTI)

    Apte, Michael G.; Faulkner, David; Hodgson, Alfred T.; Sullivan, Douglas P.

    2004-10-14T23:59:59.000Z

    The primary goals of this research effort are to develop, evaluate, and demonstrate a very practical HVAC system for classrooms that consistently provides classrooms (CRs) with the quantity of ventilation in current minimum standards, while saving energy, and reducing HVAC-related noise levels. This research is motivated by the public benefits of energy efficiency, evidence that many CRs are under-ventilated, and public concerns about indoor environmental quality in CRs. This document provides a summary of the detailed plans developed for the field study that will take place in 2005 to evaluate the energy and IAQ performance of a new classroom HVAC technology. The field study will include measurements of HVAC energy use, ventilation rates, and IEQ conditions in 10 classrooms with the new HVAC technology and in six control classrooms with a standard HVAC system. Energy use and many IEQ parameters will be monitored continuously, while other IEQ measurements will be will be performed seasonally. Continuously monitored data will be remotely accessed via a LonWorks network. Instrument calibration plans that vary with the type of instrumentation used are established. Statistical tests will be employed to compare energy use and IEQ conditions with the new and standard HVAC systems. Strengths of this study plan include the collection of real time data for a full school year, the use of high quality instrumentation, the incorporation of many quality control measures, and the extensive collaborations with industry that limit costs to the sponsors.

  18. PROJECT REPORT HVAC EQUIPMENT DEMOGRAPHICS AND CAPACITY

    E-Print Network [OSTI]

    California at Davis, University of

    - nently reduce the connected capacity, with respect to the HVAC system, by disconnecting compressors within RTUs that contain multiple compressors. We reviewed existing literature and col- lected primary data by conducting field surveys in order to estab- lish how multiple compressor RTUs are typically

  19. Energy Master Plans for Sustainable, High Performance HVAC and Associated Systems for Hot and Humid Climates

    E-Print Network [OSTI]

    Maisey, G. E.; Milestone, B.

    2004-01-01T23:59:59.000Z

    of the upper management objectives and strategies. If upper management considers comfort and productivity an issue, then it will be improved. If upper management considers energy efficiency and overall maintenance effectiveness an issue, it will improve... than the ambient temperature for thermal comfort. A radiant temperature system using water in pipes, serpentined in the ceiling and floor, walls, etc., not only will provide better comfort, but it can move energy around ten times more efficiently...

  20. Development of a Thermoelectric Device for an Automotive Zonal HVAC System

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny:Revised Finding of No53197E T A * S HBatteries withAbstractSystemHydrocarbon

  1. Model Predictive Control of HVAC Systems: Implementation and Testing at the University of California, Merced

    SciTech Connect (OSTI)

    Haves, Phillip; Hencey, Brandon; Borrell, Francesco; Elliot, John; Ma, Yudong; Coffey, Brian; Bengea, Sorin; Wetter, Michael

    2010-06-29T23:59:59.000Z

    A Model Predictive Control algorithm was developed for the UC Merced campus chilled water plant. Model predictive control (MPC) is an advanced control technology that has proven successful in the chemical process industry and other industries. The main goal of the research was to demonstrate the practical and commercial viability of MPC for optimization of building energy systems. The control algorithms were developed and implemented in MATLAB, allowing for rapid development, performance, and robustness assessment. The UC Merced chilled water plant includes three water-cooled chillers and a two million gallon chilled water storage tank. The tank is charged during the night to minimize on-peak electricity consumption and take advantage of the lower ambient wet bulb temperature. The control algorithms determined the optimal chilled water plant operation including chilled water supply (CHWS) temperature set-point, condenser water supply (CWS) temperature set-point and the charging start and stop times to minimize a cost function that includes energy consumption and peak electrical demand over a 3-day prediction horizon. A detailed model of the chilled water plant and simplified models of the buildings served by the plant were developed using the equation-based modeling language Modelica. Steady state models of the chillers, cooling towers and pumps were developed, based on manufacturers performance data, and calibrated using measured data collected and archived by the control system. A detailed dynamic model of the chilled water storage tank was also developed and calibrated. Simple, semi-empirical models were developed to predict the temperature and flow rate of the chilled water returning to the plant from the buildings. These models were then combined and simplified for use in a model predictive control algorithm that determines the optimal chiller start and stop times and set-points for the condenser water temperature and the chilled water supply temperature. The report describes the development and testing of the algorithm and evaluates the resulting performance, concluding with a discussion of next steps in further research. The experimental results show a small improvement in COP over the baseline policy but it is difficult to draw any strong conclusions about the energy savings potential for MPC with this system only four days of suitable experimental data were obtained once correct operation of the MPC system had been achieved. These data show an improvement in COP of 3.1% {+-} 2.2% relative to a baseline established immediately prior to the period when the MPC was run in its final form. This baseline includes control policy improvements that the plant operators learned by observing the earlier implementations of MPC, including increasing the temperature of the water supplied to the chiller condensers from the cooling towers. The process of data collection and model development, necessary for any MPC project, resulted in the team uncovering various problems with the chilled water system. Although it is difficult to quantify the energy savings resulting from these problems being remedied, they were likely on the same order as the energy savings from the MPC itself. Although the types of problems uncovered and the level of energy savings may differ significantly from other projects, some of the benefits of detecting and diagnosing problems are expected from the use of MPC for any chilled water plant. The degree of chiller loading was found to be a key factor for efficiency. It is more efficient to operate the chillers at or near full load. In order to maximize the chiller load, one would maximize the temperature difference across chillers and the chilled water flow rate through the chillers. Thus, the CHWS set-point and the chilled water flow-rate can be used to limit the chiller loading to prevent chiller surging. Since the flow rate has an upper bound and the CHWS set point has a lower bound, the chiller loading is constrained and often determined by the chilled water return temperature (CHWR). The CHWR temperature

  2. Columbia Water and Light- Residential HVAC Rebate Program

    Broader source: Energy.gov [DOE]

    Columbia Water and Light (CWL) provides an HVAC incentive for residential customers that are replacing an older heating and cooling system. Customers should submit the mechanical permit from a...

  3. Advanced control strategies for HVAC&R systems—An overview: Part II: Soft and fusion control

    SciTech Connect (OSTI)

    D. Subbaram Naidu; Craig G. Rieger

    2011-04-01T23:59:59.000Z

    A chronological overview of the advanced control strategies for HVAC&R is presented. The overview focuses on hard-computing or control techniques, such as proportional-integral-derivative, optimal, nonlinear, adaptive, and robust; soft-computing or control techniques, such as neural networks, fuzzy logic, genetic algorithms; and the fusion or hybrid of hard and soft control techniques. Part I focused on hardcontrol strategies; Part II focuses on soft and fusion control and some future directions in HVA&R research. This overview is not intended to be an exhaustive survey on this topic, and any omissions of other works is purely unintentional.

  4. The Impact of Uncertain Physical Parameters on HVAC Demand Response

    SciTech Connect (OSTI)

    Sun, Yannan; Elizondo, Marcelo A.; Lu, Shuai; Fuller, Jason C.

    2014-03-01T23:59:59.000Z

    HVAC units are currently one of the major resources providing demand response (DR) in residential buildings. Models of HVAC with DR function can improve understanding of its impact on power system operations and facilitate the deployment of DR technologies. This paper investigates the importance of various physical parameters and their distributions to the HVAC response to DR signals, which is a key step to the construction of HVAC models for a population of units with insufficient data. These parameters include the size of floors, insulation efficiency, the amount of solid mass in the house, and efficiency of the HVAC units. These parameters are usually assumed to follow Gaussian or Uniform distributions. We study the effect of uncertainty in the chosen parameter distributions on the aggregate HVAC response to DR signals, during transient phase and in steady state. We use a quasi-Monte Carlo sampling method with linear regression and Prony analysis to evaluate sensitivity of DR output to the uncertainty in the distribution parameters. The significance ranking on the uncertainty sources is given for future guidance in the modeling of HVAC demand response.

  5. Comparative Study of Availability on Energy/Environment Commissioning Using Existing HVAC Simulation Programs for a Model Building

    E-Print Network [OSTI]

    Niwa, H.; Nakahara, N.; Okumiya, M.; Suganaga, M.; Tanaka, H.; Pan, S.; Watanabe, T.; Zheng, M.

    2004-01-01T23:59:59.000Z

    limit of VAV air flow rate: 50% of minimum ? Heat Source System: Thermal storage system using AHP(Air-soure HeatPumps) ? Performance characteristics of fan, pump, heat pump are defined as manufacturer's ? Internal heat gain schedules are set...

  6. A Runtime Verification Framework for Control System Simulation

    SciTech Connect (OSTI)

    Ciraci, Selim; Fuller, Jason C.; Daily, Jeffrey A.; Makhmalbaf, Atefe; Callahan, Charles D.

    2014-08-02T23:59:59.000Z

    n a standard workflow for the validation of a control system, the control system is implemented as an extension to a simulator. Such simulators are complex software systems, and engineers may unknowingly violate constraints a simulator places on extensions. As such, errors may be introduced in the implementation of either the control system or the simulator leading to invalid simulation results. This paper presents a novel runtime verification approach for verifying control system implementations within simulators. The major contribution of the approach is the two-tier specification process. In the first tier, engineers model constraints using a domain-specific language tailored to modeling a controller’s response to changes in its input. The language is high-level and effectively hides the implementation details of the simulator, allowing engineers to specify design-level constraints independent of low-level simulator interfaces. In the second tier, simulator developers provide mapping rules for mapping design-level constraints to the implementation of the simulator. Using the rules, an automated tool transforms the design-level specifications into simulator-specific runtime verification specifications and generates monitoring code which is injected into the implementation of the simulator. During simulation, these monitors observe the input and output variables of the control system and report changes to the verifier. The verifier checks whether these changes follow the constraints of the control system. We describe application of this approach to the verification of the constraints of an HVAC control system implemented with the power grid simulator GridLAB-D.

  7. Personalized HVAC control system

    E-Print Network [OSTI]

    Feldmeier, Mark Christopher

    We present a novel method of building comfort control, focused around the occupant. Custom sensing, communication, and actuation hardware were developed to locate users in a building, and measure various parameters directly ...

  8. A New Model to Simulate Energy Performance of VRF Systems

    SciTech Connect (OSTI)

    Hong, Tianzhen; Pang, Xiufeng; Schetrit, Oren; Wang, Liping; Kasahara, Shinichi; Yura, Yoshinori; Hinokuma, Ryohei

    2014-03-30T23:59:59.000Z

    This paper presents a new model to simulate energy performance of variable refrigerant flow (VRF) systems in heat pump operation mode (either cooling or heating is provided but not simultaneously). The main improvement of the new model is the introduction of the evaporating and condensing temperature in the indoor and outdoor unit capacity modifier functions. The independent variables in the capacity modifier functions of the existing VRF model in EnergyPlus are mainly room wet-bulb temperature and outdoor dry-bulb temperature in cooling mode and room dry-bulb temperature and outdoor wet-bulb temperature in heating mode. The new approach allows compliance with different specifications of each indoor unit so that the modeling accuracy is improved. The new VRF model was implemented in a custom version of EnergyPlus 7.2. This paper first describes the algorithm for the new VRF model, which is then used to simulate the energy performance of a VRF system in a Prototype House in California that complies with the requirements of Title 24 ? the California Building Energy Efficiency Standards. The VRF system performance is then compared with three other types of HVAC systems: the Title 24-2005 Baseline system, the traditional High Efficiency system, and the EnergyStar Heat Pump system in three typical California climates: Sunnyvale, Pasadena and Fresno. Calculated energy savings from the VRF systems are significant. The HVAC site energy savings range from 51 to 85percent, while the TDV (Time Dependent Valuation) energy savings range from 31 to 66percent compared to the Title 24 Baseline Systems across the three climates. The largest energy savings are in Fresno climate followed by Sunnyvale and Pasadena. The paper discusses various characteristics of the VRF systems contributing to the energy savings. It should be noted that these savings are calculated using the Title 24 prototype House D under standard operating conditions. Actual performance of the VRF systems for real houses under real operating conditions will vary.

  9. High-Speed Internet Access via HVAC Ducts: A New Approach Daniel D. Stancil, Ozan K. Tonguz, Ariton Xhafa, Ahmet Cepni, and Pavel Nikitin

    E-Print Network [OSTI]

    Stancil, Daniel D.

    High-Speed Internet Access via HVAC Ducts: A New Approach Daniel D. Stancil, Ozan K. Tonguz, Ariton conditioning (HVAC) ducts for indoor wireless transmission systems and networks. Mea- surements and system to 100 Mbps should be possible, when HVAC system is used in con- junction with OFDM technology. Keywords

  10. Classroom HVAC: Improving ventilation and saving energy -- field study plan

    E-Print Network [OSTI]

    Apte, Michael G.; Faulkner, David; Hodgson, Alfred T.; Sullivan, Douglas P.

    2004-01-01T23:59:59.000Z

    in this study. Classroom HVAC: Improving Ventilation andV8doc.sas.com/sashtml. Classroom HVAC: Improving VentilationBerkeley, CA 94720. Classroom HVAC: Improving Ventilation

  11. HVAC component data modeling using industry foundation classes

    E-Print Network [OSTI]

    Bazjanac, Vladimir; Forester, James; Haves, Philip; Sucic, Darko; Xu, Peng

    2002-01-01T23:59:59.000Z

    HVAC Component Data Modeling Using Industry Foundationof a major extension of the HVAC part of the IFC data model.generic approach for handling HVAC components. This includes

  12. HVAC Market Study:

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField8,Dist.NewofGeothermal848 Unlimited Release1/2 HR 1.00 $ ForHVAC Market

  13. Chapter 19: HVAC Controls (DDC/EMS/BAS) Evaluation Protocol

    SciTech Connect (OSTI)

    Romberger, J.

    2014-11-01T23:59:59.000Z

    The HVAC Controls Evaluation Protocol is designed to address evaluation issues for direct digital controls/energy management systems/building automation systems (DDC/EMS/BAS) that are installed to control heating, ventilation, and air-conditioning (HVAC) equipment in commercial and institutional buildings. (This chapter refers to the DDC/EMS/BAS measure as HVAC controls.) This protocol may also be applicable to industrial facilities such as clean rooms and labs, which have either significant HVAC equipment or spaces requiring special environmental conditions. This protocol addresses only HVAC-related equipment and the energy savings estimation methods associated with installing such control systems as an energy efficiency measure. The affected equipment includes: Air-side equipment (air handlers, direct expansion systems, furnaces, other heating- and cooling-related devices, terminal air distribution equipment, and fans); Central plant equipment (chillers, cooling towers, boilers, and pumps). These controls may also operate or affect other end uses, such as lighting, domestic hot water, irrigation systems, and life safety systems such as fire alarms and other security systems. Considerable nonenergy benefits, such as maintenance scheduling, system component troubleshooting, equipment failure alarms, and increased equipment lifetime, may also be associated with these systems. When connected to building utility meters, these systems can also be valuable demand-limiting control tools. However, this protocol does not evaluate any of these additional capabilities and benefits.

  14. Review of Pre- and Post-1980 Buildings in CBECS - HVAC Equipment

    SciTech Connect (OSTI)

    Winiarski, David W.; Jiang, Wei; Halverson, Mark A.

    2006-12-01T23:59:59.000Z

    PNNL was tasked by DOE to look at HVAC systems and equipment for Benchmark buildings based on 2003 CBECS data. This white paper summarizes the results of PNNL’s analysis of 2003 CBECS data and provides PNNL’s recommendations for HVAC systems and equipment for use in the Benchmark buildings.

  15. Monitoring-based HVAC Commissioning of an Existing Office Building for Energy Efficiciency

    E-Print Network [OSTI]

    Wang, Liping

    2014-01-01T23:59:59.000Z

    EnergyPlus, Trend Data Introduction The performance of HVACthe commissioning of HVAC systems. Analyzing trend data is aHVAC systems, such as improper operations of air-side economizers, simultaneous heating and cooling, and ineffective optimal start, were identified through trend

  16. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, VOL. 51, NO. 5, MAY 2003 945 Propagation Model for the HVAC Duct as a

    E-Print Network [OSTI]

    Stancil, Daniel D.

    for the HVAC Duct as a Communication Channel Pavel V. Nikitin, Member, IEEE, Daniel D. Stancil, Senior Member (HVAC) ducts in buildings are typically hollow metal pipes which can be used as waveguides to carry such a communication system. This paper presents a propagation model for a straight HVAC duct terminated at both ends

  17. An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings

    E-Print Network [OSTI]

    Trcka, Marija

    2010-01-01T23:59:59.000Z

    Canada. Conference ACKNOWLEDGEMENTS This research was supported by the Assistant Secretary for Energy Efficiency and Renewable

  18. An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings

    E-Print Network [OSTI]

    Trcka, Marija

    2010-01-01T23:59:59.000Z

    Canada. Conference ACKNOWLEDGEMENTS This research was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy,

  19. HVAC's Variable Refrigerant Flow (VRF) Technology

    E-Print Network [OSTI]

    Jones, S.

    2012-01-01T23:59:59.000Z

    1 Comfort by Design Steve Jones Commercial Sales Manager for Mitsubishi Southwest Business Unit HVAC?s Variable Refrigerant Flow (VRF) Technology HVAC Industry Overview HVAC Market Dollar Volume $18 Billion Source:;NABH Research... Moveable Ductless 5 VRF Technology Overview 6 What is VRF Technology? Variable Refrigerant Flow More Comfort, Less Energy Usage 8 INVERTER-driven Compressor Time R oo m T em pe ra tur e ? Enables capacity operation as low as 4% ? Sizing...

  20. Pedernales Electric Cooperative- HVAC Rebate Program

    Broader source: Energy.gov [DOE]

    Pedernales Electric Cooperative offers equipment rebates to its members who install energy efficient HVAC equipment. Eligible equipment includes:

  1. Diagnosis of Effectiveness of HVAC System and Energy Performance of Osaka-Gas Building through Retro-Commissioning Part 1 Outline of HVAC Systems and Diagnosis of Energy Efficiency of Air Systems

    E-Print Network [OSTI]

    Hatanaka,T.; Aoki,K; Matsuda, N.; Yamaha,M.; Tanaka,H.; Nakahara,N.

    2014-01-01T23:59:59.000Z

    volumes in the AC-22 system at 11:00 on January 17, 2014 Based on Fig. 6.4, the cold air/warm air ratio in the cooling/heating areas is as follows: Cooling supply area: QH = 0.22QC Heating supply area: QC = 0.10QH 11?00 17?00 INV Output % Power...

  2. A Method for On-Going Commissioning of VRV Package Systems Using a Simulation Model

    E-Print Network [OSTI]

    Yamaha, M.; Sekiyama, K.; Misaki, S.

    2006-01-01T23:59:59.000Z

    Variable refrigerant volume (VRV) systems, which have several indoor units and a single outdoor unit, have become very popular HVAC systems in Japan. However, some systems may be operated under inefficient conditions and consume excessive energy...

  3. Best practices guide for residential HVAC Retrofits

    SciTech Connect (OSTI)

    Walker, Iain S.

    2003-08-11T23:59:59.000Z

    This best practices guide for residential HVAC system retrofits is aimed at contractors who want guidance on delivering energy efficient, cost effective and innovative products. It has been developed around the idea of having packages of changes to the building HVAC system and building envelope that are climate and house construction dependent. These packages include materials, procedures and equipment and are designed to remove some of the guesswork from a builder, contractor, installer or homeowner decisions about how best to carry out HVAC changes. The packages are not meant to be taken as rigid requirements--instead they are systems engineered guidelines that form the basis for energy efficient retrofits. Similar approaches have been taken previously for new construction to develop extremely energy efficient homes that are comfortable safe and durable, and often cost less than standard construction. This is best epitomized by the Building America program whose partners have built thousands of residences throughout the U.S. using these principles. The differences between retrofitting and new construction tend to limit the changes one can make to a building, so these packages rely on relatively simple and non-intrusive technologies and techniques. The retrofits also focus on changes to a building that will give many years of service to the occupants. Another key aspect of these best practices is that we need to know how a house is working so that we know what parts have the potential for improvement. To do this we have put together a set of diagnostic tools that combine physical measurements and checklists/questionnaires. The measured test results, observations and homeowner answers to questions are used to direct us towards the best retrofits applicable to each individual house. The retrofits will depend on the current condition of the building envelope and HVAC system, the local climate, the construction methods used for the house, and the presence of various energy saving systems (e.g., a Heat Recovery Ventilator) and/or materials. This is just like a doctor referring a patient for blood tests or x-rays before actually performing surgery. This way the doctor can be sure that he does the right thing. To take this analogy further--we can borrow from the medical profession and say that the first thought when retrofitting a house is to do no harm, i.e., do not make changes that could make the house worse to live in.

  4. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (http://www.hvac.okstate.edu).

    E-Print Network [OSTI]

    function (TF) method was the method of choice for cooling load calculation. There- fore, information; Rundquist 1990; Treado and Bean 1992). Recently, ASHRAE developed two new cooling load calculation: Chantrasrisalai, C., and D.E. Fisher. 2007. Lighting heat gain parameters: Experimental results. HVAC&R Research

  5. Simulating neural systems with Xyce.

    SciTech Connect (OSTI)

    Schiek, Richard Louis; Thornquist, Heidi K.; Mei, Ting; Warrender, Christina E.; Aimone, James Bradley; Teeter, Corinne; Duda, Alex M. [University of Illinois, Urbana-Champaign

    2012-12-01T23:59:59.000Z

    Sandia's parallel circuit simulator, Xyce, can address large scale neuron simulations in a new way extending the range within which one can perform high-fidelity, multi-compartment neuron simulations. This report documents the implementation of neuron devices in Xyce, their use in simulation and analysis of neuron systems.

  6. Green Scheduling: Scheduling of Control Systems for Peak Power Reduction

    E-Print Network [OSTI]

    Pappas, George J.

    and refrigera- tion (HVAC&R) system, chiller systems, and lighting systems trigger concurrently resulting

  7. IEEE TRANSACTIONS ON COMMUNICATIONS, VOL. 53, NO. 2, FEBRUARY 2005 335 On the Capacity Limits of HVAC Duct Channel for

    E-Print Network [OSTI]

    Stancil, Daniel D.

    and experimental channel-capacity estimates of heating, ventilation, and air condi- tioning (HVAC) ducts based in indoor wireless networks. Index Terms--Heating, ventilation, and air conditioning (HVAC) systems building is already equipped with a microwave distribution system: the heating, ventilation, and air

  8. Co-Simulation of Building Energy and Control Systems with the Building Controls Virtual Test Bed

    SciTech Connect (OSTI)

    Wetter, Michael

    2010-08-22T23:59:59.000Z

    This article describes the implementation of the Building Controls Virtual Test Bed (BCVTB). The BCVTB is a software environment that allows connecting different simulation programs to exchange data during the time integration, and that allows conducting hardware in the loop simulation. The software architecture is a modular design based on Ptolemy II, a software environment for design and analysis of heterogeneous systems. Ptolemy II provides a graphical model building environment, synchronizes the exchanged data and visualizes the system evolution during run-time. The BCVTB provides additions to Ptolemy II that allow the run-time coupling of different simulation programs for data exchange, including EnergyPlus, MATLAB, Simulink and the Modelica modelling and simulation environment Dymola. The additions also allow executing system commands, such as a script that executes a Radiance simulation. In this article, the software architecture is presented and the mathematical model used to implement the co-simulation is discussed. The simulation program interface that the BCVTB provides is explained. The article concludes by presenting applications in which different state of the art simulation programs are linked for run-time data exchange. This link allows the use of the simulation program that is best suited for the particular problem to model building heat transfer, HVAC system dynamics and control algorithms, and to compute a solution to the coupled problem using co-simulation.

  9. Scaling and Optimization of Magnetic Refrigeration for Commercial Building HVAC Systems Greater than 175 kW in Capacity

    SciTech Connect (OSTI)

    Abdelaziz, Omar [ORNL] [ORNL; West, David L [ORNL] [ORNL; Mallow, Anne M [ORNL] [ORNL

    2012-01-01T23:59:59.000Z

    Heating, ventilation, air-conditioning and refrigeration (HVACR) account for approximately one- third of building energy consumption. Magnetic refrigeration presents an opportunity for significant energy savings and emissions reduction for serving the building heating, cooling, and refrigeration loads. In this paper, we have examined the magnet and MCE material requirements for scaling magnetic refrigeration systems for commercial building cooling applications. Scaling relationships governing the resources required for magnetic refrigeration systems have been developed. As system refrigeration capacity increases, the use of superconducting magnet systems becomes more applicable, and a comparison is presented of system requirements for permanent and superconducting (SC) magnetization systems. Included in this analysis is an investigation of the ability of superconducting magnet based systems to overcome the parasitic power penalty of the cryocooler used to keep SC windings at cryogenic temperatures. Scaling relationships were used to develop the initial specification for a SC magnet-based active magnetic regeneration (AMR) system. An optimized superconducting magnet was designed to support this system. In this analysis, we show that the SC magnet system consisting of two 0.38 m3 regenerators is capable of producing 285 kW of cooling power with a T of 28 K. A system COP of 4.02 including cryocooler and fan losses which illustrates that an SC magnet-based system can operate with efficiency comparable to traditional systems and deliver large cooling powers of 285.4 kW (81.2 Tons).

  10. Analysis of Innovative HVAC System Technologies and Their Application for Office Buildings in Hot and Humid Climates 

    E-Print Network [OSTI]

    Tanskyi, Oleksandr

    2012-02-14T23:59:59.000Z

    to evaluate energy reduction potential and the performance of innovative technologies such as dedicated outdoor air system, displacement ventilation, improved cooling system efficiency, air source heat pumps and natural gas heat pumps....

  11. Compression effects on pressure loss in flexible HVAC ducts

    E-Print Network [OSTI]

    Abushakra, Bass; Walker, Iain S.; Sherman, Max H.

    2002-01-01T23:59:59.000Z

    to Determine Flow Resistance of HVAC Air Ducts and Fittings.Pressure Loss in Flexible HVAC Ducts Bass Abushakra, Ph.D.to Determine Flow Resistance of HVAC Air Ducts and Fittings.

  12. Fouling of HVAC fin and tube heat exchangers

    E-Print Network [OSTI]

    Siegel, Jeffrey; Carey, Van P.

    2001-01-01T23:59:59.000Z

    air ? air ? part ? part FPI HVAC REFERENCES Anonymous, 1987,LBNL-47668 Fouling of HVAC Fin and Tube Heat ExchangersCIEE SPONSOR. FOULING OF HVAC FIN AND TUBE HEAT EXCHANGERS

  13. Simulation of open quantum systems

    E-Print Network [OSTI]

    Florian Mintert; Eric J. Heller

    2008-03-27T23:59:59.000Z

    We present an approach for the semiclassical treatment of open quantum systems. An expansion into localized states allows restriction of a simulation to a fraction of the environment that is located within a predefined vicinity of the system. Adding and dropping environmental particles during the simulation yields an effective reduction of the size of the system that is being treated.

  14. D-Zero HVAC Heat Pump Controls

    SciTech Connect (OSTI)

    Markley, Dan; /Fermilab

    2004-04-14T23:59:59.000Z

    This engineering note documents the integration of Dzero Heat Pump 1 through Heat Pump 15 into the cryo/gas process control system commonly referred to as the cryo control system. Heat pumps 1 through 15 control the ambient air temperature on the 3rd, 5th, and 6th floor office areas at Dzero. The entire Johnson HVAC control system was replaced with a Siemens control system in 1999 leaving behind the 15 heat pumps with stand-alone Johnson controllers. Now, these 15 heat pump Johnson controllers are being replaced with small stand alone Beckhoff BC9000 controllers. The Beckhoff BC9000 controllers are network able into the existing Intellution control system. The Beckhoff BC9000 controllers use the cryo private Ethernet network and an OPC driver to get data into the Intellution SCADA node databases. The BC9000 is also programmed over this same Ethernet network.

  15. Building America Webinar: HVAC Right-Sizing Part 1-Calculating...

    Energy Savers [EERE]

    HVAC Right-Sizing Part 1-Calculating Loads Building America Webinar: HVAC Right-Sizing Part 1-Calculating Loads During this webinar, Building America Research Team IBACOS...

  16. Presented at SimBuild 2004, August 4-6, 2004, Boulder, CO, and published in the proceedings. A Simulation-Based Testing and Training Environment for Building

    E-Print Network [OSTI]

    in the proceedings. A Simulation-Based Testing and Training Environment for Building Controls Peng Xu and Philip, Building Sustainability and Performance Through Simulation, August 4-6, 2004, Boulder, CO, USA A SIMULATION for controls testing and training is described. A real-time simulation of a building and HVAC system is coupled

  17. Building America Expert Meeting: Transitioning Traditional HVAC...

    Energy Savers [EERE]

    validate the general business models for traditional HVAC companies and whole house energy upgrade companies Review preliminary findings on the differences between the structure...

  18. Columbia Water & Light- Residential HVAC Rebates

    Broader source: Energy.gov [DOE]

    Columbia Water & Light (CWL) provides residential customers with rebates on energy efficient HVAC equipment. Customers should submit the mechanical permit from a Protective Inspection, a copy...

  19. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (http://www.hvac.okstate.edu).

    E-Print Network [OSTI]

    Elementalheatexchangermodelsareincreasinglyusedin heat pump design calculations because of their ability to accu. INTRODUCTION The heat exchanger model is an important aspect of the overall design and simulation of the air-to-air heat pump. There are many convergence criteria in the system design and simulation program

  20. Quantitative Methods for Comparing Different HVAC Control Schemes

    E-Print Network [OSTI]

    Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

    2012-01-01T23:59:59.000Z

    Experimentally comparing the energy usage and comfort characteristics of different controllers in heating, ventilation, and air-conditioning (HVAC) systems is difficult because variations in weather and occupancy conditions preclude the possibility of establishing equivalent experimental conditions across the order of hours, days, and weeks. This paper is concerned with defining quantitative metrics of energy usage and occupant comfort, which can be computed and compared in a rigorous manner that is capable of determining whether differences between controllers are statistically significant in the presence of such environmental fluctuations. Experimental case studies are presented that compare two alternative controllers (a schedule controller and a hybrid system learning-based model predictive controller) to the default controller in a building-wide HVAC system. Lastly, we discuss how our proposed methodology may also be able to quantify the efficiency of other building automation systems.

  1. SIMMODEL: A DOMAIN DATA MODEL FOR WHOLE BUILDING ENERGY SIMULATION

    E-Print Network [OSTI]

    O'Donnell, James

    2013-01-01T23:59:59.000Z

    whole building energy simulation program. In: IBPSA BuildingExchange Protocols for Energy Simulation of HVAC&R EquipmentInteroperability for Energy Simulation. buildingSmart (2010)

  2. Residential HVAC Indoor Air Quality(ASHRAE 62.2)

    E-Print Network [OSTI]

    Residential HVAC && Indoor Air Quality(ASHRAE 62.2) Tav Commins #12;Contact Information · Energy construction, Additions /Alterations · Nonresidential and Residential #12;Residential HVAC && Indoor Air Quality(ASHRAE 62.2) ·HVAC EfficiencyHVAC Efficiency ·Quality Installation (HERS Measures) S li b HERS R t

  3. HVAC Modeling for Cost of Ownership Assessment in Biotechnology & Drugs Manufacturing

    E-Print Network [OSTI]

    Broomes, Peter; Dornfeld, David A

    2003-01-01T23:59:59.000Z

    2000 Broomes, Peter. , “HVAC Modeling for Cost of Ownership2000 Broomes, Peter. , “HVAC Results Comparison”, April,HVAC Modeling for Cost of Ownership Assessment in

  4. Investigation of IAQ-Relevant Surface Chemistry and Emissions on HVAC Filter Materials

    E-Print Network [OSTI]

    Destaillats, Hugo

    2010-01-01T23:59:59.000Z

    VOCs emitted by reactions of HVAC filters with ozone usingChemistry and Emissions on HVAC Filter Materials HugoChemistry and Emissions on HVAC Filter Materials Authors:

  5. Laboratory measurement of secondary pollutant yields from ozone reaction with HVAC filters.

    E-Print Network [OSTI]

    Destaillats, Hugo

    2012-01-01T23:59:59.000Z

    from Ozone Reaction with HVAC Filters Hugo Destaillats,from Ozone Reaction with HVAC Filters Hugo Destaillatsfrom Ozone Reaction with HVAC Filters Hugo Destaillats

  6. An Evaluation of the HVAC Load Potential for Providing Load Balancing Service

    SciTech Connect (OSTI)

    Lu, Ning

    2012-09-30T23:59:59.000Z

    This paper investigates the potential of providing aggregated intra-hour load balancing services using heating, ventilating, and air-conditioning (HVAC) systems. A direct-load control algorithm is presented. A temperature-priority-list method is used to dispatch the HVAC loads optimally to maintain consumer-desired indoor temperatures and load diversity. Realistic intra-hour load balancing signals were used to evaluate the operational characteristics of the HVAC load under different outdoor temperature profiles and different indoor temperature settings. The number of HVAC units needed is also investigated. Modeling results suggest that the number of HVACs needed to provide a {+-}1-MW load balancing service 24 hours a day varies significantly with baseline settings, high and low temperature settings, and the outdoor temperatures. The results demonstrate that the intra-hour load balancing service provided by HVAC loads meet the performance requirements and can become a major source of revenue for load-serving entities where the smart grid infrastructure enables direct load control over the HAVC loads.

  7. Nuclear Systems Modeling & Simulation | More Science | ORNL

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Systems Modeling and Simulation SHARE Nuclear Systems Modeling and Simulation Reactor physics depletion model for the Advanced Test Reactor Reactor physics depletion model for the...

  8. Nuclear Systems Modeling, Simulation & Validation | ORNL

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Systems Modeling and Simulation SHARE Nuclear Systems Modeling, Simulation and Validation Reactor physics depletion model for the Advanced Test Reactor Reactor physics depletion...

  9. Experimental results of a predictive neural network HVAC controller

    SciTech Connect (OSTI)

    Jeannette, E.; Assawamartbunlue, K.; Kreider, J.F. [Univ. of Colorado, Boulder, CO (United States); Curtiss, P.S. [Architectural Energy Corp., Boulder, CO (United States)

    1998-12-31T23:59:59.000Z

    Proportional, integral, and derivative (PID) control is widely used in many HVAC control processes and requires constant attention for optimal control. Artificial neural networks offer the potential for improved control of processes through predictive techniques. This paper introduces and shows experimental results of a predictive neural network (PNN) controller applied to an unstable hot water system in an air-handling unit. Actual laboratory testing of the PNN and PID controllers show favorable results for the PNN controller.

  10. Study on Control Performance of HVAC System or Interior Zone and Perimeter Zone in Office Building; Estimation of Optimal PI Tuning in Cooling Operation

    E-Print Network [OSTI]

    Maehara, K.; Sagara, N.

    2007-01-01T23:59:59.000Z

    of not being able to satisfy the requirements of room temperature control during the cooling period in summer, an optimal PID parameter (O-PI) is selected through simulation of its two feedback control systems with mutual influence using the models identified...

  11. ASHRAE Transactions: Symposia 1107 The interest in both modular simulation and alternative

    E-Print Network [OSTI]

    a limited Modular HVAC Simulation and the Future Integration of Alternative Cooling Systems in a New cooling systems continues to rise both in the United States and in other countries, particularly those method of the new program as back- ground and then discusses some of the alternative cooling system

  12. Recovery Act-Funded HVAC projects

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy was allocated funding from the American Recovery and Reinvestment Act to conduct research into heating, ventilation, and air conditioning (HVAC) technologies and...

  13. 1736 IEEE TRANSACTIONS ON COMMUNICATIONS, VOL. 51, NO. 10, OCTOBER 2003 Impulse Response of the HVAC Duct as a

    E-Print Network [OSTI]

    Hochberg, Michael

    Member, IEEE, and Dagfin Brodtkorb, Member, IEEE Abstract--Heating, ventilation, and air conditioning-area network (LAN). I. INTRODUCTION THE heating, ventilation, and air conditioning (HVAC) duct system in most

  14. Recovery act: development of design and simulation tool for hybrid geothermal heat pump system

    SciTech Connect (OSTI)

    Wang, Shaojie

    2014-05-29T23:59:59.000Z

    The ground source heat pump (GSHP) system is one of the most energy efficient HVAC technologies in the current market. However, the heat imbalance may degrade the ability of the ground loop heat exchanger (GLHX) to absorb or reject heat. The hybrid GSHP system, which combines a geothermal well field with a supplemental boiler or cooling tower, can balance the loads imposed on the ground loop heat exchangers to minimize its size while retaining superior energy efficiency. This paper presents a recent simulation-based study with an intention to compare multiple common control strategies used in hybrid GSHP systems, including fixed setpoint, outside air reset, load reset, and wetbulb reset. A small office in Oklahoma City conditioned by a hybrid GSHP system was simulated with the latest version of eQUEST 3.7[1]. The simulation results reveal that the hybrid GSHP system has the excellent capability to meet the cooling and heating setpoints during the occupied hours, balance thermal loads on the ground loop, as well as improve the thermal comfort of the occupants with the undersized well field.

  15. SERI DOE-2 solar simulator study

    SciTech Connect (OSTI)

    Eden, A.; Simms, D.A.

    1980-01-01T23:59:59.000Z

    The Solar Energy Research Institute's (SERI) analysis of the solar energy simulator section of DOE-2, a public domain computer program that allows users to explore the energy-use patterns of proposed and existing buildings and their heating, ventilating, and air conditioning (HVAC) systems is discussed. This computer program contains a solar energy simulation portion called Component-Based Simulator (CBS) incorporated into the HVAC Plant (large equipment) section. SERI is investigating the adequacy and sensitivity of DOE-2's solar portion when various active solar energy systems and combinations of solar components are interfaced with standard space conditioning systems or used in a stand-alone mode. The components have been assembled into typical configurations and parametric test runs have been performed examining the problems associated with the program and the characteristics of the output for eventual comparison with other energy analysis computer programs.

  16. VARIABLE SPEED INTEGRATED INTELLIGENT HVAC BLOWER

    SciTech Connect (OSTI)

    Shixiao Wang; Herman Wiegman; Wilson Wu; John Down; Luana Iorio; Asha Devarajan; Jing Wang; Ralph Carl; Charlie Stephens; Jeannine Jones; Paul Szczesny

    2001-11-14T23:59:59.000Z

    This comprehensive topical report discusses the key findings in the development of a intelligent integrated blower for HVAC applications. The benefits of rearward inclined blades over that of traditional forward inclined blades is well documented and a prototype blower design is presented. A comparison of the proposed blower to that of three typical units from the industry is presented. The design of the blower housing is also addressed and the impact of size limitations on static efficiency is discussed. Issues of air flow controllability in the rearward inclined blower is addressed and a solution to this problem is proposed. Several motor design options are discussed including inside-out radial flux designs and novel axial flux designs, all are focused on the various blower needs. The control of the motor-blower and airflow through the use of a high density inverter stage and modern digital signal processor is presented. The key technical challenges of the approach are discussed. The use of the motor as a sensor in the larger heating/ventilating system is also discussed. Diagnostic results for both the motor itself and the blower system are presented.

  17. Atmospheric Environment 41 (2007) 31513160 Ozone removal by HVAC filters

    E-Print Network [OSTI]

    Siegel, Jeffrey

    Atmospheric Environment 41 (2007) 3151­3160 Ozone removal by HVAC filters P. Zhao, J.A. Siegel�, R May 2006; accepted 14 June 2006 Abstract Residential and commercial HVAC filters that have been loaded of the relative importance of HVAC filters as a removal mechanism for ozone in residential and commercial

  18. Tematiche di ricerca Controllo di sistemi HVAC&R

    E-Print Network [OSTI]

    Schenato, Luca

    Tematiche di ricerca Controllo di sistemi HVAC&R Controllo di processo per l'industria dei;Tematiche di ricerca Controllo di sistemi HVAC&R Controllo di processo per l'industria dei semiconduttori controllo di sistemi HVAC&R 2 Controllo di processo per l'industria dei semiconduttori 3 Problemi di

  19. Proceedings: Indoor Air 2005 OZONE REMOVAL BY RESIDENTIAL HVAC FILTERS

    E-Print Network [OSTI]

    Siegel, Jeffrey

    Proceedings: Indoor Air 2005 2366 OZONE REMOVAL BY RESIDENTIAL HVAC FILTERS P Zhao1,2 , JA Siegel1, Austin, Texas 78758, USA ABSTRACT HVAC filters have a significant influence on indoor air quality% for Filter #2 at a face velocity of 0.81 cm/s. The potential for HVAC filters to affect ozone concentrations

  20. An update on acoustics designs for HVAC (Engineering) K. Marriott

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    An update on acoustics designs for HVAC (Engineering) K. Marriott IOA, 29a Ashburton Road, Croydon and Air Conditioning (HVAC) engineer is to engineer ways for keeping these factors under control the HVAC engineer's environmental requirements while minimizing noise generated in the process considering

  1. Co-Simulation of Detailed Whole Building with the Power System to Study Smart Grid Applications

    SciTech Connect (OSTI)

    Makhmalbaf, Atefe; Fuller, Jason C.; Srivastava, Viraj; Ciraci, Selim; Daily, Jeffrey A.

    2014-12-24T23:59:59.000Z

    Modernization of the power system in a way that ensures a sustainable energy system is arguably one of the most pressing concerns of our time. Buildings are important components in the power system. First, they are the main consumers of electricity and secondly, they do not have constant energy demand. Conventionally, electricity has been difficult to store and should be consumed as it is generated. Therefore, maintaining the demand and supply is critical in the power system. However, to reduce the complexity of power models, buildings (i.e., end-use loads) are traditionally modeled and represented as aggregated “dumb” nodes in the power system. This means we lack effective detailed whole building energy models that can support requirements and emerging technologies of the smart power grid. To gain greater insight into the relationship between building energy demand and power system performance, it is important to constitute a co-simulation framework to support detailed building energy modeling and simulation within the power system to study capabilities promised by the modern power grid. This paper discusses ongoing work at Pacific Northwest National Laboratory and presents underlying tools and framework needed to enable co-simulation of building, building energy systems and their control in the power system to study applications such as demand response, grid-based HVAC control, and deployment of buildings for ancillary services. The optimal goal is to develop an integrated modeling and simulation platform that is flexible, reusable, and scalable. Results of this work will contribute to future building and power system studies, especially those related to the integrated ‘smart grid’. Results are also expected to advance power resiliency and local (micro) scale grid studies where several building and renewable energy systems transact energy directly. This paper also reviews some applications that can be supported and studied using the framework introduced to understand their implications before they can be successfully implemented in the power system.

  2. Continuous Energy Management of the HVAC&R System in an Office Building System Operation and Energy Consumption for the Eight Years after Building Completion

    E-Print Network [OSTI]

    Akashi, Y.; Shinozaki, M.; Kusuda, R.; Ito, S.

    2006-01-01T23:59:59.000Z

    setting was detected, and the system performance improved significantly as a result of correcting the fault. Recently, however, problematic issues, such as the malfunction of chillers and deteriorated performance of the heat exchangers, have emerged...

  3. Energy Renovations: Volume 14: HVAC - A Guide for Contractors to Share with Homeowners

    SciTech Connect (OSTI)

    Gilbride, Theresa L.; Baechler, Michael C.; Hefty, Marye G.; Hand, James R.; Love, Pat M.

    2011-08-29T23:59:59.000Z

    This report was prepared by PNNL for DOE's Building America program and is intended as a guide that energy performance contractors can share with homeowners to describe various energy-efficient options for heating, cooling, and ventilating existing homes. The report provides descriptions of many common and not-so-common HVAC systems, including their advantages and disadvantages, efficiency ranges and characteristics of high-performance models, typical costs, and climate considerations. The report also provides decision trees and tables of useful information for homeowners who are making decisions about adding, replacing, or upgrading existing HVAC equipment in their homes. Information regarding home energy performance assessments (audits) and combustion safety issues when replacing HVAC equipment are also provided.

  4. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    numerical groundwater flow and heat transfer model has been used to simulate the effects of groundwater flow

  5. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    Plus is a new whole-building energy simulation program being developed for the United States Department is modular in structure, and uses the heat balance technique to simulate building thermal loads. The Energy to calculate the airflows, which are used by EnergyPlus in the subsequent heat balance simulation. The paper

  6. Low Energy Quantum System Simulation

    E-Print Network [OSTI]

    Peter Cho; Karl Berggren

    2003-10-26T23:59:59.000Z

    A numerical method for solving Schrodinger's equation based upon a Baker-Campbell-Hausdorff (BCH) expansion of the time evolution operator is presented herein. The technique manifestly preserves wavefunction norm, and it can be applied to problems in any number of spatial dimensions. We also identify a particular dimensionless ratio of potential to kinetic energies as a key coupling constant. This coupling establishes characteristic length and time scales for a large class of low energy quantum states, and it guides the choice of step sizes in numerical work. Using the BCH method in conjunction with an imaginary time rotation, we compute low energy eigenstates for several quantum systems coupled to non-trivial background potentials. The approach is subsequently applied to the study of 1D propagating wave packets and 2D bound state time development. Failures of classical expectations uncovered by simulations of these simple systems help develop quantum intuition. Finally, we investigate the response of a Superconducting Quantum Interference Device (SQUID) to a time dependent potential. We discuss how to engineer the potential's energy and time scales so that the SQUID acts as a quantum NOT gate. The notional simulation we present for this gate provides useful insight into the design of one candidate building block for a quantum computer.

  7. University of North Carolina at Charlotte Design and Construction Manual Section 2, Division 23 HVAC

    E-Print Network [OSTI]

    Xie,Jiang (Linda)

    ­ HVAC SECTION 2 DIVISION 23 HVAC #12;University of North Carolina at Charlotte Design and Construction Manual Section 2, Division 23 ­ HVAC DIVISION 23 - HVAC Note: This is a guide for Designers only 23 0510 - MECHANICAL GENERAL - HVAC PART 1 - GENERAL 1.1 MECHANICAL DESIGNER: A. Design

  8. Modeling Building Thermal Response to HVAC Virginia Smith, Tamim Sookoor, and Kamin Whitehouse

    E-Print Network [OSTI]

    Whitehouse, Kamin

    by the occupants. Much of this wasted energy is used to heat or cool unoccupied spaces during long periods when-15% waste due to unoccupied spaces be- ing conditioned. Our goal is to minimize this waste by retrofitting the influence of the HVAC system. We present a technique for dynamically estimating the heat load due to weather

  9. VOL. 6, NO. 1 HVAC&R RESEARCH JANUARY 2000 Qualitative Comparison of North American and

    E-Print Network [OSTI]

    Calculation of design cooling and heating loads is an essential task in the design of HVAC systems and has societies publish methods for calculating design cooling and heating load calculations in their handbooks.K. Cooling Load Calculation Methods Simon J. Rees, Ph.D Jeffrey D. Spitler, Ph.D., P.E. Member ASHRAE Member

  10. Uncertainties in Achieving Energy Savings from HVAC Maintenance Measures in the Field

    E-Print Network [OSTI]

    California at Davis, University of

    Uncertainties in Achieving Energy Savings from HVAC Maintenance Measures in the Field Kristin Group, Davis, CA, USA 4 Southern California Edison, Irwindale, CA, USA ABSTRACT HVAC maintenance utilities across the nation to include HVAC maintenance measures in energy efficiency programs

  11. Method for simulating discontinuous physical systems

    DOE Patents [OSTI]

    Baty, Roy S. (Albuquerque, NM); Vaughn, Mark R. (Albuquerque, NM)

    2001-01-01T23:59:59.000Z

    The mathematical foundations of conventional numerical simulation of physical systems provide no consistent description of the behavior of such systems when subjected to discontinuous physical influences. As a result, the numerical simulation of such problems requires ad hoc encoding of specific experimental results in order to address the behavior of such discontinuous physical systems. In the present invention, these foundations are replaced by a new combination of generalized function theory and nonstandard analysis. The result is a class of new approaches to the numerical simulation of physical systems which allows the accurate and well-behaved simulation of discontinuous and other difficult physical systems, as well as simpler physical systems. Applications of this new class of numerical simulation techniques to process control, robotics, and apparatus design are outlined.

  12. Thermoelectric HVAC and Thermal Comfort Enablers for Light-Duty...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and Thermal Comfort Enablers for Light-Duty Vehicle Applications Thermoelectric HVAC and Thermal Comfort Enablers for Light-Duty Vehicle Applications 2012 DOE Hydrogen and Fuel...

  13. 2014-04-28 Issuance: Certification of Commercial HVAC, Water...

    Broader source: Energy.gov (indexed) [DOE]

    heating, ventilation, and air-conditioning (HVAC), water heating (WH), and refrigeration (CRE) equipment, as issued by the Deputy Assistant Secretary for Energy Efficiency...

  14. Pre-Commercial Demonstration of Cost-Effective Advanced HVAC...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Hayden Reeve, United Technologies Research Center Optimal control coordination of heating, ventilation, and air conditioning (HVAC) equipment can reduce energy by more than...

  15. HVAC Cabinet Air Leakage Test Method - Building America Top Innovation...

    Broader source: Energy.gov (indexed) [DOE]

    Furthermore, this research led to the creation of ASHRAE Standard 193, "Method of Test for Determining the Airtightness of HVAC Equipment," which was ready for adoption in...

  16. HVAC Efficiency Controls Could Mean Significant Savings | Department...

    Energy Savers [EERE]

    to produce more advanced HVAC controllers and for building owners to adopt these energy-saving methods." The PNNL team hopes the report will encourage manufacturers to...

  17. Columbia Water and Light- HVAC and Lighting Efficiency Rebates

    Broader source: Energy.gov [DOE]

    Columbia Water and Light (CWL) offers rebates to its commercial and industrial customers for the purchase of high efficiency HVAC installations and efficient lighting. Incentives for certain...

  18. DOE Convening Report on Certification of Commercial HVAC and...

    Broader source: Energy.gov (indexed) [DOE]

    of a negotiated rulemaking to revise the certification program for commercial HVAC and CRE products published on October 2, 2012. conveningreporthvaccre1.pdf More...

  19. Two Alabama Elementary Schools Get Cool with New HVAC Units ...

    Broader source: Energy.gov (indexed) [DOE]

    campaign. Winston's HVAC replacement project received a boost from the Alabama State Energy Program, which granted the school district a little more than 82,000 in Recovery...

  20. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    efficient than conventional air-to-air systems. In practice, ground-source heat pump systems have also.J. Rees, and C. Yavuzturk. 2000. Recent Developments in Ground Source Heat Pump System Design, Modelling A28, p.34. #12;Page 1 of 1 Recent Developments in Ground Source Heat Pump System Design, Modeling

  1. Short communication Optimization of hybrid ground coupled and air source heat pump systems

    E-Print Network [OSTI]

    Fernández de Córdoba, Pedro

    Short communication Optimization of hybrid ­ ground coupled and air source ­ heat pump systems 2008 Accepted 14 January 2010 Available online 28 January 2010 Keywords: Ground coupled heat pump Air to water heat pump Thermal storage device Hybrid HVAC system Energy efficiency Numerical simulation a b

  2. Interdisciplinary Innovation and Vision in the HVAC 

    E-Print Network [OSTI]

    Hecker, T.

    2008-01-01T23:59:59.000Z

    8th International Conference for Enhanced Building Operations - ICEBO?08 Conference Center of the Federal Ministry of Economics and Technology Berlin, October 20 - 22, 2008 Tomas Hecker AL-KO Therm GmbH Hauptstrasse 248 - 250 89343... Jettingen-Scheppach 00 49 82 25/ 39 - 1 28 tomas.hecker@al-ko.de Interdisciplinary Innovation and Vision in the HVAC High energy costs in buildings are forcing the building owners, developers, fund and facility managers to find alternate energy...

  3. Daylighting controls; Orphan of HVAC design

    SciTech Connect (OSTI)

    Rundquist, R.A. (R.A. Rundquist Associates Inc., Northampton, MA (US))

    1991-11-01T23:59:59.000Z

    This paper reports that in the array of strategies employed for energy-efficient design and retrofitting in commercial buildings, the use of daylighting controls is often overlooked or omitted. Thus, daylighting controls are a worthy but neglected orphan of the design process, stranded between the lighting designer, architect and engineer. Most daylighting analysis ignores HVAC effects, despite obvious interactions between windows, heat-from-lights, and thermal loads.

  4. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    is presented. INTRODUCTION Although originating in the residential building sector, ground-source heat pump conductivity is a signif- icant challenge facing designers of ground-source heat pump (GSHP heat pump systems" may include a range of system configurations, closed-loop systems, where the ground

  5. Simulation model air-to-air plate heat exchanger

    SciTech Connect (OSTI)

    Wetter, Michael

    1999-01-01T23:59:59.000Z

    A simple simulation model of an air-to-air plate heat exchanger is presented. The model belongs to a collection of simulation models that allows the eflcient computer simulation of heating, ventilation, and air-conditioning (HVAC) systems. The main emphasis of the models is to shorten computation time and to use only input data that are known in the design process of an HVAC system. The target of the models is to describe the behavior of HVAC components in the part-load operation mode, which is becoming increasingly important in energy eficient HVAC systems. The models are intended to be used for yearly energy calculations or load calculations with time steps of about 10 minutes or larger. Short- time dynamic effects, which are of interest for different aspects of control theory, are neglected. The part-load behavior is expressed in terms of the nominal condition and the dimensionless variation of the heat transfer with change of mass flow and temperature. The effectiveness- NTU relations are used to parametrize the convective heat transfer at nominal conditions and to compute the part-load condition. If the heat transfer coefficients on the two exchanger sides are not equal (i. e. due to partial bypassing of air), their ratio can be easily calculated and set as a parameter. The model is static and uses explicit equations only. The explicit model formulation ensures short computation time and numerical stability, which allows using the model with sophisticated engineering methods like automatic system optimization. This paper fully outlines the algorithm description and its simplifications. It is not tailored for any particular simulation program to ensure easy implementation in any simulation program.

  6. PV modules, with a life measured in decades, will typically be in place longer than the outdoor unit of a HVAC system.

    E-Print Network [OSTI]

    Johnson, Eric E.

    PV modules, with a life measured in decades, will typically be in place longer than the outdoor and repaired promptly. PV systems suffer gradual degradation that is often not monitored, and the PV array may with copper conductors. On the other hand, PV systems have numerous modules (tens to thousands) and mounting

  7. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    system with condensing gas boilers and vapor compression refrigeration. Introduction Ground source heat to that of a conventional system with condensing gas boilers and vapor compression refrigeration. #12;Building Representative time series of heating and cooling plant demands were required for the analysis of the ground

  8. A New Approach to Commissioning of the VAV Control System

    E-Print Network [OSTI]

    Han, Z.; Xia, C.; Zhu, Y.; Xu, G.

    2006-01-01T23:59:59.000Z

    Commissioning of the HVAC system has been practiced in buildings for the purpose of energy conservation and performance optimization. Commissioning of the HVAC automation system should be paid more attention. In this paper, Objective Control Method...

  9. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    Ghajar, Afshin J.

    to reductions in electrical energy usage, and allow more effective demand-side management. However, comparedThis paper has been downloaded from the Building and Environmental Thermal Systems Research Group

  10. Better Buildings Neighborhood Program Business Models Guide: HVAC Contractor Business Model Introduction

    Broader source: Energy.gov [DOE]

    Better Buildings Neighborhood Program Business Models Guide: HVAC Contractor Business Model Introduction.

  11. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (http://www.hvac.okstate.edu).

    E-Print Network [OSTI]

    This paper has been downloaded from the Building and Environmental Thermal Systems Research Group that is typically only the case for envelope-dominated buildings in a given location. · Reasonably constant ground thermal properties between locations for which the rule-of-thumb would be applied. The main example

  12. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (http://www.hvac.okstate.edu).

    E-Print Network [OSTI]

    -source heat pump (GSHP) systems have been gaining increasing popularity in commercial and residential in construction to a domestic water well). Water is circulated from the well through the heat pump in an open, water is recirculated between the well and the building (heat pump). Deep bores are drilled in hard rock

  13. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    International Heat Pumps in Cold Climates Conference, Aylmer, Québec. August 17-18, 2000. #12;GLHEPRO ­ A DESIGN University Stillwater, OK, U.S.A. KEY WORDS Ground source heat pump systems, ground loop heat exchangers size in order to meet user-specified minimum or maximum heat pump entering fluid temperatures

  14. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    include improved performance of heat pumps with water as the working fluid (instead of air) and lower.D. Smith, J.D. Spitler. 2002. Advances in Ground Source Heat Pump Systems - An International Overview. Proceedings of the Seventh International Energy Agency Heat Pump Conference. 1:313-324. Beijing. May 19

  15. This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)

    E-Print Network [OSTI]

    environmental systems. The accuracy ofthe thermal load calculation procedure is, therefore, ofconcern to heating oftwo newproceduresfor design cooling load calculations: the heat balance method (HBM) andradiant time (Spitler et al. 1997) is a simplified, heat balance-based design cooling load method intended

  16. Green Scheduling of Control Systems for Peak Demand Reduction Truong X. Nghiem, Madhur Behl, Rahul Mangharam and George J. Pappas

    E-Print Network [OSTI]

    Pappas, George J.

    and refrigeration (HVAC&R) systems, chiller sys- tems, and lighting systems operate independently of each other

  17. POEM: Power-efficient Occupancy-based Energy Management System

    E-Print Network [OSTI]

    Cerpa, Alberto E.

    for Heating Ventilation and Air-Conditioning (HVAC) systems. Current HVAC systems only condition based to reach target temperatures and minimize ventilation requirements. Based on live tests of the system, we, Measurement, Performance Keywords Occupancy, HVAC, Ventilation, Energy savings 1. INTRODUCTION Permission

  18. Modeling of Diesel Exhaust Systems: A methodology to better simulate...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Diesel Exhaust Systems: A methodology to better simulate soot reactivity Modeling of Diesel Exhaust Systems: A methodology to better simulate soot reactivity Discussed...

  19. Vehicle Technologies Office: 2013 Vehicle and Systems Simulation...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Vehicle Technologies Office: 2013 Vehicle and Systems Simulation and Testing R&D Annual Progress Report Vehicle Technologies Office: 2013 Vehicle and Systems Simulation and Testing...

  20. Communication Simulations for Power System Applications

    SciTech Connect (OSTI)

    Fuller, Jason C.; Ciraci, Selim; Daily, Jeffrey A.; Fisher, Andrew R.; Hauer, Matthew L.

    2013-05-29T23:59:59.000Z

    New smart grid technologies and concepts, such as dynamic pricing, demand response, dynamic state estimation, and wide area monitoring, protection, and control, are expected to require considerable communication resources. As the cost of retrofit can be high, future power grids will require the integration of high-speed, secure connections with legacy communication systems, while still providing adequate system control and security. While considerable work has been performed to create co-simulators for the power domain with load models and market operations, limited work has been performed in integrating communications directly into a power domain solver. The simulation of communication and power systems will become more important as the two systems become more inter-related. This paper will discuss ongoing work at Pacific Northwest National Laboratory to create a flexible, high-speed power and communication system co-simulator for smart grid applications. The framework for the software will be described, including architecture considerations for modular, high performance computing and large-scale scalability (serialization, load balancing, partitioning, cross-platform support, etc.). The current simulator supports the ns-3 (telecommunications) and GridLAB-D (distribution systems) simulators. Ongoing and future work will be described, including planned future expansions for a traditional transmission solver. A test case using the co-simulator, utilizing a transactive demand response system created for the Olympic Peninsula and AEP gridSMART demonstrations, requiring two-way communication between distributed and centralized market devices, will be used to demonstrate the value and intended purpose of the co-simulation environment.

  1. Simulation framework for intelligent transportation systems

    SciTech Connect (OSTI)

    Ewing, T.; Doss, E.; Hanebutte, U.; Tentner, A.

    1996-10-01T23:59:59.000Z

    A simulation framework has been developed for a large-scale, comprehensive, scaleable simulation of an Intelligent Transportation System (ITS). The simulator is designed for running on parallel computers and distributed (networked) computer systems, but can run on standalone workstations for smaller simulations. The simulator currently models instrumented smart vehicles with in-vehicle navigation units capable of optimal route planning and Traffic Management Centers (TMC). The TMC has probe vehicle tracking capabilities (display position and attributes of instrumented vehicles), and can provide two-way interaction with traffic to provide advisories and link times. Both the in-vehicle navigation module and the TMC feature detailed graphical user interfaces to support human-factors studies. Realistic modeling of variations of the posted driving speed are based on human factors studies that take into consideration weather, road conditions, driver personality and behavior, and vehicle type. The prototype has been developed on a distributed system of networked UNIX computers but is designed to run on parallel computers, such as ANL`s IBM SP-2, for large-scale problems. A novel feature of the approach is that vehicles are represented by autonomous computer processes which exchange messages with other processes. The vehicles have a behavior model which governs route selection and driving behavior, and can react to external traffic events much like real vehicles. With this approach, the simulation is scaleable to take advantage of emerging massively parallel processor (MPP) systems.

  2. Self-Correcting HVAC Controls Project Final Report

    SciTech Connect (OSTI)

    Fernandez, Nicholas; Brambley, Michael R.; Katipamula, Srinivas; Cho, Heejin; Goddard, James K.; Dinh, Liem H.

    2010-01-04T23:59:59.000Z

    This document represents the final project report for the Self-Correcting Heating, Ventilating and Air-Conditioning (HVAC) Controls Project jointly funded by Bonneville Power Administration (BPA) and the U.S. Department of Energy (DOE) Building Technologies Program (BTP). The project, initiated in October 2008, focused on exploratory initial development of self-correcting controls for selected HVAC components in air handlers. This report, along with the companion report documenting the algorithms developed, Self-Correcting HVAC Controls: Algorithms for Sensors and Dampers in Air-Handling Units (Fernandez et al. 2009), document the work performed and results of this project.

  3. Wireless Demand Response Controls for HVAC Systems

    E-Print Network [OSTI]

    Federspiel, Clifford

    2010-01-01T23:59:59.000Z

    Strategies Linking Demand Response and Energy Efficiency,”Fully Automated Demand Response Tests in Large Facilities,technical support from the Demand Response Research Center (

  4. Case Studies of Commissioning HVAC Systems

    E-Print Network [OSTI]

    Browning, B. K.

    2001-01-01T23:59:59.000Z

    This paper discusses problems found during third party commissioning of projects where humidity control was an indicator of significant problems. Project 1 was an 8000 square foot library. Problems found included air conditioning (A/C) and heating...

  5. Wireless Demand Response Controls for HVAC Systems

    E-Print Network [OSTI]

    Federspiel, Clifford

    2010-01-01T23:59:59.000Z

    to the most recent CBECS survey (EIA, 2003) only 24% of theEIA, 2003, “Commercial Building Energy Consumption Survey,”

  6. Wireless Demand Response Controls for HVAC Systems

    E-Print Network [OSTI]

    Federspiel, Clifford

    2010-01-01T23:59:59.000Z

    temperature-based demand response in buildings that havedemand response advantages of global zone temperature setup in buildings

  7. Advanced HVAC Systems | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently20,000 RussianBy:Whether you're a16-17, 201529, 2015Lead Performer: OakJoeLead

  8. Co-simulation for performance prediction of integrated building and HVAC systems - An analysis of solution characteristics using a two-body system

    E-Print Network [OSTI]

    Trcka, Marija

    2010-01-01T23:59:59.000Z

    buildings and heating, ventilation and air- conditioning (building type, heating, ventilation and air-conditioning (

  9. Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1

    E-Print Network [OSTI]

    Johnson, F.X.

    2010-01-01T23:59:59.000Z

    of contractors in the HVAC market will certainly have anational version of the HVAC market share decision model,equipment 4.5. HVAC Equipment Market Shares We now define

  10. Influence Of Three Dynamic Predictive Clothing Insulation Models On Building Energy Use, HVAC Sizing And Thermal Comfort

    E-Print Network [OSTI]

    Schiavon, Stefano; Lee, Kwang Ho

    2013-01-01T23:59:59.000Z

    ON BUILDING ENERGY USE, HVAC SIZING AND THERMAL COMFORT aThe results showed that when the HVAC is controlled based onequipment sizing. When the HVAC is controlled based on the

  11. Strategy Guideline: Transitioning HVAC Companies to Whole House Performance Contractors

    SciTech Connect (OSTI)

    Burdick, A.

    2012-05-01T23:59:59.000Z

    This report describes the findings from research IBACOS conducted related to heating, ventilation, and air conditioning (HVAC) companies who have made the decision to transition to whole house performance contracting (WHPC).

  12. HVAC EFFICIENCY BUSINESS CASE DEMAND CONTROL KITCHEN VENTILATION

    E-Print Network [OSTI]

    California at Davis, University of

    HVAC EFFICIENCY BUSINESS CASE DEMAND CONTROL KITCHEN VENTILATION Selecting, financing ventilation (DCKV) for kitchen exhaust hoods. Implementation can be relatively simple in either new of demand control kitchen ventilation (DCKV) in many small, medium, and large kitchen exhaust hood

  13. Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics

    E-Print Network [OSTI]

    Graham, E. L.

    1980-01-01T23:59:59.000Z

    Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate...

  14. STATE OF CALIFORNIA CERTIFICATE OF COMPLIANCE, PRESCRIPTIVE HVAC ALTERATIONS

    E-Print Network [OSTI]

    Equipment Equipment Type, Efficiency and Capacity 1 Floor Area Served 2 Distribution Type and Location 3 Equipment Type; Air Handler, Condenser, Heat Pump, Evap. Cooling, Boiler, Electric Resistance, etc. & HVAC

  15. Ameren Illinois (Electric)- Custom, HVAC, and Motor Business Efficiency Incentives

    Broader source: Energy.gov [DOE]

    Prescriptive rebates are available for many HVAC and motor efficiency improvements. Pre-approval is required for all rebates. The programs are available only to non-residential customers that...

  16. Argonne simulation framework for intelligent transportation systems

    SciTech Connect (OSTI)

    Ewing, T.; Doss, E.; Hanebutte, U.; Canfield, T.; Brown-VanHoozer, A.; Tentner, A.

    1996-04-01T23:59:59.000Z

    A simulation framework has been developed which defines a high-level architecture for a large-scale, comprehensive, scalable simulation of an Intelligent Transportation System (ITS). The simulator is designed to run on parallel computers and distributed (networked) computer systems; however, a version for a stand alone workstation is also available. The ITS simulator includes an Expert Driver Model (EDM) of instrumented ``smart`` vehicles with in-vehicle navigation units. The EDM is capable of performing optimal route planning and communicating with Traffic Management Centers (TMC). A dynamic road map data base is sued for optimum route planning, where the data is updated periodically to reflect any changes in road or weather conditions. The TMC has probe vehicle tracking capabilities (display position and attributes of instrumented vehicles), and can provide 2-way interaction with traffic to provide advisories and link times. Both the in-vehicle navigation module and the TMC feature detailed graphical user interfaces that includes human-factors studies to support safety and operational research. Realistic modeling of variations of the posted driving speed are based on human factor studies that take into consideration weather, road conditions, driver`s personality and behavior and vehicle type. The simulator has been developed on a distributed system of networked UNIX computers, but is designed to run on ANL`s IBM SP-X parallel computer system for large scale problems. A novel feature of the developed simulator is that vehicles will be represented by autonomous computer processes, each with a behavior model which performs independent route selection and reacts to external traffic events much like real vehicles. Vehicle processes interact with each other and with ITS components by exchanging messages. With this approach, one will be able to take advantage of emerging massively parallel processor (MPP) systems.

  17. Theory and Simulation of Multiphase Polymer Systems

    E-Print Network [OSTI]

    Friederike Schmid

    2010-01-08T23:59:59.000Z

    The theory of multiphase polymer systems has a venerable tradition. The 'classical' theory of polymer demixing, the Flory-Huggins theory, was developed already in the forties of the last century. It is still the starting point for most current approaches -- be they improved theories for polymer (im)miscibility that take into account the microscopic structure of blends more accurately, or sophisticated field theories that allow to study inhomogeneous multicomponent systems of polymers with arbitrary architectures in arbitrary geometries. In contrast, simulations of multiphase polymer systems are relatively young. They are still limited by the fact that one must simulate a large number of large molecules in order to obtain meaningful results. Both powerful computers and smart modeling and simulation approaches are necessary to overcome this problem. This article gives an overview over the state-of-the art in both areas, theory and simulation. While the theory has reached a fairly mature stage by now, and many aspects of it are covered in textbooks on polymer physics, the information on simulations is much more scattered. This is why some effort has been invested into putting together a representative list of references in this area (up to the year of 2008) -- which is of course still far from complete.

  18. Expert systems for design and simulation

    SciTech Connect (OSTI)

    Aldridge, J.; Cerutti, J.; Draisin, W.; Steuerwalt, M.

    1985-01-01T23:59:59.000Z

    We discuss work in progress on two expert systems. We are developing systems that use artificial intelligence techniques to simplify the use of large simulation codes and to help design complicated physical devices. The simulation codes are used in analyzing and designing weapons, and the devices are themselves part of weapon systems. But we focus not only on the particular applications, but also on the broader issues common to design problems: large solution spaces and tentative reasoning. We also discuss some practical difficulties encountered during the project. One expert system provides an interface between users and several simulation codes. It checks input for errors, builds input files for the codes, and submits jobs to a central computing facility. The other expert system helps turn a description of a device into a particular design. Currently this expert system includes three major parts: a translator of descriptions into designs, a graphics interface that presents the design to the user and allows him to manipulate it, and a refiner of designs. The latter is the ''smartest'' part of the system, and the target of much of our present efforts.

  19. LHC RF System Time-Domain Simulation

    SciTech Connect (OSTI)

    Mastorides, T.; Rivetta, C.; /SLAC

    2010-09-14T23:59:59.000Z

    Non-linear time-domain simulations have been developed for the Positron-Electron Project (PEP-II) and the Large Hadron Collider (LHC). These simulations capture the dynamic behavior of the RF station-beam interaction and are structured to reproduce the technical characteristics of the system (noise contributions, non-linear elements, and more). As such, they provide useful results and insight for the development and design of future LLRF feedback systems. They are also a valuable tool for the study of diverse longitudinal beam dynamics effects such as coupled-bunch impedance driven instabilities and single bunch longitudinal emittance growth. Results from these studies and related measurements from PEP-II and LHC have been presented in multiple places. This report presents an example of the time-domain simulation implementation for the LHC.

  20. Design and Optimization of Control Strategies and Parameters by Building and System Simulation 

    E-Print Network [OSTI]

    Baumann, O.

    2003-01-01T23:59:59.000Z

    . The shading system is controlled by the building control system to ensure proper operation in particularly during unoccupied periods. HVAC System Central heating system The central heating system consists of two heat pumps and one wood-fired furnace.... The ground water coupled heat pumps, 120 kW each, supply the basic load for heating at low temperatures of 28 ?C (82 ?F) to a maximum of 35 ?C (95 ?F). At these supply tem- peratures, in combination with ground water tempera- tures at about 10 ?C (50 ?F...

  1. Development of Design and Simulation Tool for Hybrid Geothermal...

    Open Energy Info (EERE)

    performance analysis for various purposes, including LEED certification and optimization of building envelop andor HVAC system designs. In 2006, as a cooperative effort...

  2. Maui Electrical System Simulation Model Validation

    E-Print Network [OSTI]

    Maui Electrical System Simulation Model Validation Prepared for the U.S. Department of Energy Office of Electricity Delivery and Energy Reliability Under Award No. DE-FC-06NT42847 Task 9 Deliverable ­ Baseline Model Validation By GE Global Research Niskayuna, New York And University of Hawaii Hawaii Natural

  3. Lattice Boltzmann simulations of soft matter systems

    E-Print Network [OSTI]

    Burkhard Duenweg; Anthony J. C. Ladd

    2008-06-09T23:59:59.000Z

    This article concerns numerical simulations of the dynamics of particles immersed in a continuum solvent. As prototypical systems, we consider colloidal dispersions of spherical particles and solutions of uncharged polymers. After a brief explanation of the concept of hydrodynamic interactions, we give a general overview over the various simulation methods that have been developed to cope with the resulting computational problems. We then focus on the approach we have developed, which couples a system of particles to a lattice Boltzmann model representing the solvent degrees of freedom. The standard D3Q19 lattice Boltzmann model is derived and explained in depth, followed by a detailed discussion of complementary methods for the coupling of solvent and solute. Colloidal dispersions are best described in terms of extended particles with appropriate boundary conditions at the surfaces, while particles with internal degrees of freedom are easier to simulate as an arrangement of mass points with frictional coupling to the solvent. In both cases, particular care has been taken to simulate thermal fluctuations in a consistent way. The usefulness of this methodology is illustrated by studies from our own research, where the dynamics of colloidal and polymeric systems has been investigated in both equilibrium and nonequilibrium situations.

  4. Simulating Complex Window Systems using BSDF Data

    SciTech Connect (OSTI)

    Konstantoglou, Maria; Jonsson, Jacob; Lee, Eleanor

    2009-06-22T23:59:59.000Z

    Nowadays, virtual models are commonly used to evaluate the performance of conventional window systems. Complex fenestration systems can be difficult to simulate accurately not only because of their geometry but also because of their optical properties that scatter light in an unpredictable manner. Bi-directional Scattering Distribution Functions (BSDF) have recently been developed based on a mixture of measurements and modelling to characterize the optics of such systems. This paper describes the workflow needed to create then use these BSDF datasets in the Radiance lighting simulation software. Limited comparisons are made between visualizations produced using the standard ray-tracing method, the BSDF method, and that taken in a full-scale outdoor mockup.

  5. Simulating the Daylight Performance of Complex Fenestration Systems Using

    E-Print Network [OSTI]

    LBNL-4414E Simulating the Daylight Performance of Complex Fenestration Systems Using Bidirectional, January 21, 2011. 1 Simulating the Daylight Performance of Complex Fenestration Systems Using (BSDFs) to model the daylighting performance of complex fenestration systems (CFS), enabling greater

  6. Comparison of Two Statistical Approaches to Detect Abnormal Building Energy Consumption with Simulation Test

    E-Print Network [OSTI]

    Lin, G.; Claridge, D.

    2012-01-01T23:59:59.000Z

    ?or? Emea?Esim Eller?Building ? HVAC?system:?DDVAV ? Baseline?period:?March?August,1997 Simulation?Data?Sets 8 0...?ID Eller 1 Outside?airflow?ratio??increase?of??3.1% 2 Outside?airflow?ratio??decrease?of??3.1% 3 Cold?deck?leaving?temperature??increase?of?4?F 4 Cold?deck?leaving?temperature??decrease?of?4.5?F 5 Hot?deck?leaving?temperature??increase?of?10?F 6 Hot...

  7. Advanced simulation of intelligent transportation systems

    SciTech Connect (OSTI)

    Ewing, T.; Doss, E.; Hanebutte, U.; Tentner, A. [Argonne National Lab., IL (United States)

    1996-11-01T23:59:59.000Z

    A large-scale, comprehensive, scaleable simulation of an Intelligent Transportation System (ITS) has been developed which is capable of running on parallel computers and distributed (networked) computer systems. The simulator currently models instrumented {open_quotes}smart{close_quotes} vehicles with in-vehicle navigation units capable of optimal route planning and Traffic Management Centers (TMC). The TMC has probe vehicle tracking capabilities (display position and attributes of instrumented vehicles), and can provide two-way interaction with traffic to provide advisories and link times. Both the in-vehicle navigation module and the TMC feature detailed graphical user interfaces to support human-factors studies. The prototype has been developed on a distributed system of networked UNIX computers but is designed to run on parallel computers, such as ANL`s IBM SP-2, for large-scale problems. A novel feature of this approach is that vehicles are represented by autonomous computer processes which exchange messages with other processes. The vehicles have a behavior model which governs route selection and driving behavior, and can react to external traffic events much like real vehicles. With this approach, the simulation is scaleable to take advantage of emerging massively parallel processor (MPP) systems.

  8. Fast time domain simulation for large order hybrid systems

    E-Print Network [OSTI]

    Sou, Kin Cheong, 1979-

    2002-01-01T23:59:59.000Z

    Simulation is an important tool for the analysis and design of complex systems. As the models become more and more complex, more powerful simulation methods are desired. As an attempt to address this problem, a simulation ...

  9. Building America Whole-House Solutions for New Homes: HVAC Design...

    Energy Savers [EERE]

    HVAC Design Strategy for a Hot-Humid Production Builder Building America Whole-House Solutions for New Homes: HVAC Design Strategy for a Hot-Humid Production Builder In this...

  10. CoolCab Test and Evaluation and CoolCalc HVAC Tool Development...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Evaluation and CoolCalc HVAC Tool Development CoolCab Test and Evaluation and CoolCalc HVAC Tool Development 2012 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies...

  11. CoolCab Thermal Load Reduction Project: CoolCalc HVAC Tool Development...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Thermal Load Reduction Project: CoolCalc HVAC Tool Development CoolCab Thermal Load Reduction Project: CoolCalc HVAC Tool Development 2010 DOE Vehicle Technologies and Hydrogen...

  12. Simulation of cooling systems in gas turbines

    SciTech Connect (OSTI)

    Ebenhoch, G.; Speer, T.M. [Motoren- und Turbinen-Union Muenchen GmbH (Germany)

    1996-04-01T23:59:59.000Z

    The design of cooling systems for gas turbine engine blades and vanes calls for efficient simulation programs. The main purpose of the described program is to determine the complete boundary condition at the coolant side to support a temperature calculation for the solid. For the simulation of convection and heat pick up of the coolant flow, pressure loss, and further effects to be found in a rotating frame, the cooling systems are represented by networks of nodes and flow elements. Within each flow element the fluid flow is modeled by a system of ordinary differential equations based on the one-dimensional conservation of mass, momentum, and energy. In this respect, the computer program differs from many other network computation programs. Concerning cooling configurations in rotating systems, the solution for a single flow element or the entire flow system is not guaranteed to be unique. This is due to rotational forces in combination with heat transfer and causes considerable computational difficulties, which can be overcome by a special path following method in which the angular velocity is selected as the parameter of homotopy. Results of the program are compared with measurements for three applications.

  13. Comparison of dust from HVAC filters, indoor surfaces, and indoor air Federico Noris*

    E-Print Network [OSTI]

    Siegel, Jeffrey

    Comparison of dust from HVAC filters, indoor surfaces, and indoor air Federico Noris* , Kerry A and Environmental Engineering * Corresponding email: Fedenoris@mail.utexas.edu SUMMARY HVAC filters are long heavy metal (Pb, Cd and As) concentrations. HVAC filter microbial concentrations appear to be consistent

  14. Theoretical Estimates of HVAC Duct Channel Capacity for High-Speed Internet Access

    E-Print Network [OSTI]

    Stancil, Daniel D.

    Theoretical Estimates of HVAC Duct Channel Capacity for High-Speed Internet Access Ariton E. Xhafa-conditioning (HVAC) ducts based on multi-carrier transmission that uses M-QAM mod- ulation and measured channel- flections in HVAC ducts). Our work also shows that data rates in excess of 300 Mbps are possible over

  15. Comparison of HVAC filter test methods for particle removal efficiency Brent Stephens1,*

    E-Print Network [OSTI]

    Siegel, Jeffrey

    Comparison of HVAC filter test methods for particle removal efficiency Brent Stephens1,* , Jeffrey Introduction The use of HVAC filters in buildings is one strategy to reduce occupant exposure to particulate matter. However, HVAC filters are typically tested only in laboratory settings and little is known about

  16. Self-Correcting HVAC Controls: Algorithms for Sensors and Dampers in Air-Handling Units

    SciTech Connect (OSTI)

    Fernandez, Nicholas; Brambley, Michael R.; Katipamula, Srinivas

    2009-12-31T23:59:59.000Z

    This report documents the self-correction algorithms developed in the Self-Correcting Heating, Ventilating and Air-Conditioning (HVAC) Controls project funded jointly by the Bonneville Power Administration and the Building Technologies Program of the U.S. Department of Energy. The algorithms address faults for temperature sensors, humidity sensors, and dampers in air-handling units and correction of persistent manual overrides of automated control systems. All faults considered create energy waste when left uncorrected as is frequently the case in actual systems.

  17. A framework for on-line simulation systems

    E-Print Network [OSTI]

    Drake, Glenn Richardson

    1996-01-01T23:59:59.000Z

    Simulation has traditionally been used for off-line planning and design. The advent of computer integrated manufacturing and flexible manufacturing systems has increased interest in shop floor control systems that use simulation technology for real-time...

  18. Deposition of biological aerosols on HVAC heat exchangers

    SciTech Connect (OSTI)

    Siegel, Jeffrey; Walker, Ian

    2001-09-01T23:59:59.000Z

    Many biologically active materials are transported as bioaerosols 1-10 {micro}m in diameter. These particles can deposit on cooling and heating coils and lead to serious indoor air quality problems. This paper investigates several of the mechanisms that lead to aerosol deposition on fin and tube heat exchangers. A model has been developed that incorporates the effects of several deposition mechanisms, including impaction, Brownian and turbulent diffusion, turbophoresis, thermophoresis, diffusiophoresis, and gravitational settling. The model is applied to a typical range of air velocities that are found in commercial and residential HVAC systems 1 - 6 m/s (200 - 1200 ft/min), particle diameters from 1 - 8 {micro}m, and fin spacings from 3.2 - 7.9 fins/cm (8 - 16 fins/inch or FPI). The results from the model are compared to results from an experimental apparatus that directly measures deposition on a 4.7 fins/cm (12 FPI) coil. The model agrees reasonably well with this measured data and suggests that cooling coils are an important sink for biological aerosols and consequently a potential source of indoor air quality problems.

  19. Report on HVAC option selections for a relocatable classroom energy and indoor environmental quality field study

    SciTech Connect (OSTI)

    Apte, Michael G.; Delp, Woody W.; Diamond, Richard C.; Hodgson, Alfred T.; Kumar, Satish; Rainer, Leo I.; Shendell, Derek G.; Sullivan, Doug P.; Fisk, William J.

    2001-10-11T23:59:59.000Z

    It is commonly assumed that efforts to simultaneously develop energy efficient building technologies and to improve indoor environmental quality (IEQ) are unfeasible. The primary reason for this is that IEQ improvements often require additional ventilation that is costly from an energy standpoint. It is currently thought that health and productivity in work and learning environments requires adequate, if not superior, IEQ. Despite common assumptions, opportunities do exist to design building systems that provide improvements in both energy efficiency and IEQ. This report outlines the selection of a heating, ventilation, and air conditioning (HVAC) system to be used in demonstrating such an opportunity in a field study using relocatable school classrooms. Standard classrooms use a common wall mounted heat pump HVAC system. After reviewing alternative systems, a wall-mounting indirect/direct evaporative cooling system with an integral hydronic gas heating is selected. The anticipated advantages of this system include continuous ventilation of 100 percent outside air at or above minimum standards, projected cooling energy reductions of about 70 percent, inexpensive gas heating, improved airborne particle filtration, and reduced peak load electricity use. Potential disadvantages include restricted climate regions and possible increases in indoor relative humidity levels under some conditions.

  20. Large-scale Intelligent Transporation Systems simulation

    SciTech Connect (OSTI)

    Ewing, T.; Canfield, T.; Hannebutte, U.; Levine, D.; Tentner, A.

    1995-06-01T23:59:59.000Z

    A prototype computer system has been developed which defines a high-level architecture for a large-scale, comprehensive, scalable simulation of an Intelligent Transportation System (ITS) capable of running on massively parallel computers and distributed (networked) computer systems. The prototype includes the modelling of instrumented ``smart`` vehicles with in-vehicle navigation units capable of optimal route planning and Traffic Management Centers (TMC). The TMC has probe vehicle tracking capabilities (display position and attributes of instrumented vehicles), and can provide 2-way interaction with traffic to provide advisories and link times. Both the in-vehicle navigation module and the TMC feature detailed graphical user interfaces to support human-factors studies. The prototype has been developed on a distributed system of networked UNIX computers but is designed to run on ANL`s IBM SP-X parallel computer system for large scale problems. A novel feature of our design is that vehicles will be represented by autonomus computer processes, each with a behavior model which performs independent route selection and reacts to external traffic events much like real vehicles. With this approach, one will be able to take advantage of emerging massively parallel processor (MPP) systems.

  1. CS 661: System Simulation Spring Semester at NJIT

    E-Print Network [OSTI]

    Lin, Xiaodong

    are to learn how to plan, build and use simulation models and to develop an understanding of when simulation and software tools for building simulation models, performing experiments with them, and interpretingCS 661: System Simulation Spring Semester at NJIT Tuesday Evenings, 6:00 - 9:05pm Instructor Prof

  2. CS 661: System Simulation Spring Semester at NJIT

    E-Print Network [OSTI]

    Nakayama, Marvin K.

    are to learn how to plan, build and use simulation models and to develop an understanding of when simulation tools for building simulation models, performing experiments with them, and interpreting the resultsCS 661: System Simulation Spring Semester at NJIT Thursdays, 2:30 ­ 5:25pm Instructor Prof. Marvin

  3. Department of Mechanical Engineering Spring 2012 HVAC Filter Sensor -Global

    E-Print Network [OSTI]

    Demirel, Melik C.

    , a pressure sensor, a fan, and a photo-resistor. The photo-resistor and fan concepts were developed in the home and communicates wirelessly with the sensor. Either the photo-resistor or the fan can be usedPENNSTATE Department of Mechanical Engineering Spring 2012 HVAC Filter Sensor - Global Overview

  4. Handover Performance of HVAC Duct Based Indoor Wireless Networks

    E-Print Network [OSTI]

    Stancil, Daniel D.

    in indoor wireless net- works (IWN) that use heating, ventilation, and air conditioning (HVAC) ducts]. An alternative approach to transmitt/receive the RF signal is to use heating, ventilation, and airconditioning and is connected to one or more antennas in the duct. Each antenna acts as a remote antenna (RA) for a particular

  5. SMUD's HVAC Programs Ravi Patel-Program Planning

    E-Print Network [OSTI]

    California at Davis, University of

    with building envelop · Higher overall rebate ­ More measures may be added soon · Thermostats (pending smart-grid1 SMUD's HVAC Programs 5-7-13 Ravi Patel- Program Planning Bruce Baccei- R&D #12;SMUD's Residential program planning process · What's on the horizon for Title 24, CEE, etc? · Modify programs accordingly

  6. HVAC Design Strategy for a Hot-Humid Production Builder, Houston, Texas (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-03-01T23:59:59.000Z

    BSC worked directly with the David Weekley Homes - Houston division to redesign three floor plans in order to locate the HVAC system in conditioned space. The purpose of this project is to develop a cost effective design for moving the HVAC system into conditioned space. In addition, BSC conducted energy analysis to calculate the most economical strategy for increasing the energy performance of future production houses. This is in preparation for the upcoming code changes in 2015. The builder wishes to develop an upgrade package that will allow for a seamless transition to the new code mandate. The following research questions were addressed by this research project: 1. What is the most cost effective, best performing and most easily replicable method of locating ducts inside conditioned space for a hot-humid production home builder that constructs one and two story single family detached residences? 2. What is a cost effective and practical method of achieving 50% source energy savings vs. the 2006 International Energy Conservation Code for a hot-humid production builder? 3. How accurate are the pre-construction whole house cost estimates compared to confirmed post construction actual cost? BSC and the builder developed a duct design strategy that employs a system of dropped ceilings and attic coffers for moving the ductwork from the vented attic to conditioned space. The furnace has been moved to either a mechanical closet in the conditioned living space or a coffered space in the attic.

  7. Applications of Optimal Building Energy System Selection and Operation

    E-Print Network [OSTI]

    Marnay, Chris

    2014-01-01T23:59:59.000Z

    ventilation, and air conditioning LBNL: Ernest Orlandoventilation and air conditioning system of a universityheating ventilation and air conditioning (HVAC) system of a

  8. Scalable Scheduling of Building Control Systems for Peak Demand Reduction

    E-Print Network [OSTI]

    Pappas, George J.

    by the Department of Energy under Award Number DE-EE0004261. (HVAC&R) systems, boiler/chiller systems, and lighting

  9. Room air stratification in combined chilled ceiling and displacement ventilation systems.

    E-Print Network [OSTI]

    Schiavon, Stefano; Bauman, Fred; Tully, Brad; Rimmer, Julian

    2012-01-01T23:59:59.000Z

    and displacement ventilation systems. HVAC&R Research, 12 (and displacement ventilation system. ASHRAE RP-1438 Finalof Displacement Ventilation System—Experimental and

  10. MODELING AND SIMULATION OF HVAC FAULTS IN ENERGYPLUS

    E-Print Network [OSTI]

    Basarkar, Mangesh

    2013-01-01T23:59:59.000Z

    Survey administered by the Energy Information Agency (EIA,EIA. 2003. Commercial Building End Use Survey. http://

  11. MODELING AND SIMULATION OF HVAC FAULTS IN ENERGYPLUS

    E-Print Network [OSTI]

    Basarkar, Mangesh

    2013-01-01T23:59:59.000Z

    Mangesh Basarkar, Xiufeng Pang, Liping Wang, Philip Haves,Mangesh Basarkar, Xiufeng Pang, Liping Wang, Philip Haves,

  12. THE DOE-2 COMPUTER PROGRAM FOR THERMAL SIMULATION OF BUILDINGS

    E-Print Network [OSTI]

    of the energy addition and extraction actually to be supplied at the heating and cooling coils by the HVAC of the hour-by-hour heat loss and gain to the building spaces and the heating and cooling loads imposed upon of the HVAC system, the time-varying temperature set-points, and the heating, cooling and fan schedules

  13. Sensitivity, Approximation and Uncertainty in Power System Dynamic Simulation

    E-Print Network [OSTI]

    1 Sensitivity, Approximation and Uncertainty in Power System Dynamic Simulation Ian A. Hiskens, Fellow, IEEE Jassim Alseddiqui Student Member, IEEE Abstract-- Parameters of power system models the influence of uncertainty in simulations of power system dynamic behaviour. It is shown that trajectory

  14. Simulation- Assisted Audit of an Air Conditioned Office Building

    E-Print Network [OSTI]

    Bertagnolio, S.; Lebrun, J.; Hannay, J.; Silva, C. A.

    , an equation-based building-HVAC simulation tool is used to assist the audit. Fuel and electricity consumption are then interpreted and significant energy saving opportunities are identified....

  15. A View on Future Building System Modeling and Simulation

    SciTech Connect (OSTI)

    Wetter, Michael

    2011-04-01T23:59:59.000Z

    This chapter presents what a future environment for building system modeling and simulation may look like. As buildings continue to require increased performance and better comfort, their energy and control systems are becoming more integrated and complex. We therefore focus in this chapter on the modeling, simulation and analysis of building energy and control systems. Such systems can be classified as heterogeneous systems because they involve multiple domains, such as thermodynamics, fluid dynamics, heat and mass transfer, electrical systems, control systems and communication systems. Also, they typically involve multiple temporal and spatial scales, and their evolution can be described by coupled differential equations, discrete equations and events. Modeling and simulating such systems requires a higher level of abstraction and modularisation to manage the increased complexity compared to what is used in today's building simulation programs. Therefore, the trend towards more integrated building systems is likely to be a driving force for changing the status quo of today's building simulation programs. Thischapter discusses evolving modeling requirements and outlines a path toward a future environment for modeling and simulation of heterogeneous building systems.A range of topics that would require many additional pages of discussion has been omitted. Examples include computational fluid dynamics for air and particle flow in and around buildings, people movement, daylight simulation, uncertainty propagation and optimisation methods for building design and controls. For different discussions and perspectives on the future of building modeling and simulation, we refer to Sahlin (2000), Augenbroe (2001) and Malkawi and Augenbroe (2004).

  16. Simulation model finned water-air-coil withoutcondensation

    SciTech Connect (OSTI)

    Wetter, Michael

    1999-01-01T23:59:59.000Z

    A simple simulation model of a finned water-to- air coil without condensation is presented. The model belongs to a collection of simulation models that allows eficient computer simulation of heating, ventilation, and air-conditioning (HVAC) systems. The main emphasis of the models is short computation time and use of input data that are known in the design process of an HVAC system. The target of the models is to describe the behavior of HVAC components in the part load operation mode, which is becoming increasingly important for energy efficient HVAC systems. The models are intended to be used for yearly energy calculation or load calculation with time steps of about 10 minutes or larger. Short-time dynamic effects, which are of interest for different aspects of control performance, are neglected. The part load behavior of the coil is expressed in terms of the nominal condition and the dimensionless variation of the heat transfer with change of mass flow and temperature on the water side and the air side. The effectiveness- NTU relations are used to parametrize the convective heat transfer at nominal conditions and to compute the part load conditions. Geometrical data for the coil are not required, The calculation of the convective heat transfer coefficients at nominal conditions is based on the ratio of the air side heat transfer coefficients multiplied by the fin eficiency and divided by the water side heat transfer coefficient. In this approach, the only geometrical information required are the cross section areas, which are needed to calculate the~uid velocities. The formulas for estimating this ratio are presented. For simplicity the model ignores condensation. The model is static and uses only explicit equations. The explicit formulation ensures short computation time and numerical stability. This allows using the model with sophisticated engineering methods such as automatic system optimization. The paper fully outlines the algorithm description and its simplifications. It is not tailored for a particular simulation program to ensure easy implementation in any simulation program.

  17. Educational systems need appropriate animations and simulations Ruddy LELOUCHE

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    -mail: LELOUCHE@IFT.ULAVAL.CA Abstract Animations and simulations are often presented as tools for learning in a simulation-based system to help practising and learning algorithmics. Finally, the paper proposes a guideline, learning activity, knowledge type. Résumé Les animations et les simulations sont souvent présentées comme

  18. Chapter 5: Lighting, HVAC, and Plumbing

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Design Mechanical System Design Central Plant Systems Plumbing and Water Use Building Control Systems Electrical Power Systems Metering LANL | Chapter 5 High-Performance...

  19. CHARACTERIZATION OF AIRFLOWS NEAR THE EXIT OF HVAC REGISTERS USING LASER DOPPLER VELOCIMETRY (LDV).

    SciTech Connect (OSTI)

    TUTU,N.K.; KRISHNA,C.R.; ANDREWS,J.W.; BUTCHER,T.A.

    2003-03-13T23:59:59.000Z

    A facility to characterize the airflow at the exit of HVAC registers was designed and fabricated. The objective of this work is to obtain velocity and turbulence data at the exit of registers, which can then be used as an input boundary condition in a modern Computational Fluid Dynamics (CFD) code to predict the velocity and temperature distribution in an enclosure, and also the register performance parameters such as throw. During the course of this work, two commonly used registers were tested. Both registers were 8 inch x 4 inch sidewall registers. Laser Doppler Velocimetry was used to measure the axial and vertical components of the velocity vector at various locations across the face of the registers. For the two cases of registers studied here, the results suggest that the velocity field at the very exit of each of these registers scales with the flow rate through the registers. This means that, in the mode of operation in which the supply fan (of an HVAC system) has a ''High'' and ''Low'' setting, similar velocity scaling would result for the type of registers tested here.

  20. Explosive simulants for testing explosive detection systems

    DOE Patents [OSTI]

    Kury, John W. (Danville, CA); Anderson, Brian L. (Lodi, CA)

    1999-09-28T23:59:59.000Z

    Explosives simulants that include non-explosive components are disclosed that facilitate testing of equipment designed to remotely detect explosives. The simulants are non-explosive, non-hazardous materials that can be safely handled without any significant precautions. The simulants imitate real explosives in terms of mass density, effective atomic number, x-ray transmission properties, and physical form, including moldable plastics and emulsions/gels.

  1. Simulating Complex Window Systems using BSDF Data

    E-Print Network [OSTI]

    Konstantoglou, Maria

    2011-01-01T23:59:59.000Z

    BSDF simulated values, due to differences in sky luminancesky distribution, modelled interior and exterior conditions, and slight differences in location of view. Still, the luminance

  2. R&D Opportunity Assessment: Joining Technologies in HVAC&R -...

    Energy Savers [EERE]

    Joining Technologies in HVAC&R More Documents & Publications Research & Development Roadmap: Next-Generation Low Global Warming Potential Refrigerants Advanced Rotating Heat...

  3. Simulation methods for the development of modular strategic guidance systems

    E-Print Network [OSTI]

    Long, Stephen Michael, Ensign

    2003-01-01T23:59:59.000Z

    The traditional approach to simulation-based system design results in a stovepiped development process where subsystems are developed independently and integration requirements are then levied on the system architecture. ...

  4. The Simulation of Synchronous Reactive Systems In Ptolemy II

    E-Print Network [OSTI]

    The Simulation of Synchronous Reactive Systems In Ptolemy II by Paul Whitaker Submitted to the Department of Electrical Engineering and Computer Sciences, University of California at Berkeley, in partial;_____________________________________________________________________ Simulation of Synchronous Reactive Systems in Ptolemy II ii Abstract The Synchronous Reactive (SR) domain

  5. Dynamic wind turbine models in power system simulation tool

    E-Print Network [OSTI]

    Dynamic wind turbine models in power system simulation tool DIgSILENT Anca D. Hansen, Florin Iov Iov, Poul Sørensen, Nicolaos Cutululis, Clemens Jauch, Frede Blaabjerg Title: Dynamic wind turbine system simulation tool PowerFactory DIgSILENT for different wind turbine concepts. It is the second

  6. Integrated Hybrid-Simulation of Electric Power and Communications Systems

    SciTech Connect (OSTI)

    Nutaro, James J [ORNL; Kuruganti, Phani Teja [ORNL; Miller, Laurie E [ORNL; Mullen, Sara [ORNL; Shankar, Mallikarjun [ORNL

    2007-01-01T23:59:59.000Z

    The modern power grid is strongly integrated with its communication network. While a power system primarily consists of elements that are modeled by continuous equations, a communication system has discrete event dynamics. We model the integrated operation of these two systems with a hybrid modeling and simulation technique. Systematically combining continuous and discrete event system models is necessary for correctly simulating critical system behaviors. This paper discusses an approach based on the discrete event system specification (DEVS) that characterizes the interaction of the two systems formally to preserve simulation correctness. We demonstrate the implementation of our integrated hybrid simulation technique with detailed generator and network models in a wide-area cooperative automatic load-control scenario.

  7. Simulation Models for Improved Water Heating Systems

    E-Print Network [OSTI]

    Lutz, Jim

    2014-01-01T23:59:59.000Z

    and Simulation of a Smart Water Heater. ” In Workshop inFreezers, Furnaces, Water Heaters, Room and Central AirNovember. ADL. 1982b. Water Heater Computer Model User’s

  8. Driven harmonic oscillator as a quantum simulator for open systems

    E-Print Network [OSTI]

    Jyrki Piilo; Sabrina Maniscalco

    2006-10-03T23:59:59.000Z

    We show theoretically how a driven harmonic oscillator can be used as a quantum simulator for non-Markovian damped harmonic oscillator. In the general framework, the results demonstrate the possibility to use a closed system as a simulator for open quantum systems. The quantum simulator is based on sets of controlled drives of the closed harmonic oscillator with appropriately tailored electric field pulses. The non-Markovian dynamics of the damped harmonic oscillator is obtained by using the information about the spectral density of the open system when averaging over the drives of the closed oscillator. We consider single trapped ions as a specific physical implementation of the simulator, and we show how the simulator approach reveals new physical insight into the open system dynamics, e.g. the characteristic quantum mechanical non-Markovian oscillatory behavior of the energy of the damped oscillator, usually obtained by the non-Lindblad-type master equation, can have a simple semiclassical interpretation.

  9. Building America Webinar: High Performance Space Conditioning Systems, Part I

    Broader source: Energy.gov [DOE]

    The webinar on Oct. 23, 2014 focused on strategies to improve the performance of HVAC systems for low load homes and home performance retrofits.

  10. Building America Webinar: High Performance Space Conditioning Systems, Part II

    Broader source: Energy.gov [DOE]

    The webinar on Nov. 18, 2014, continued the series on strategies to improve the performance of HVAC systems for low load homes and home performance retrofits.

  11. Simulation of the secondary air system of aero engines

    SciTech Connect (OSTI)

    Kutz, K.J.; Speer, T.M. (MTU Motoren- und Turbinen-Union Muenchen GmbH, Munich (Germany))

    1994-04-01T23:59:59.000Z

    This paper describes a computer program for the simulation of secondary air systems. Typical flow system elements are presented, such as restrictors, tappings, seals, vortices, and coverplates. Two-phase flow as occurring in bearing chamber vent systems is briefly discussed. An algorithm is described for the solution of the resulting nonlinear equations. The validity of the simulation over the engine operation envelope is demonstrated by a comparison with test results.

  12. Demo Abstract: TOSS: Thermal Occupancy Sensing System

    E-Print Network [OSTI]

    Cerpa, Alberto E.

    materials harnessing passive solar technologies along with increasingly efficient HVAC systems have,jlusby,acerpa}@andes.ucmerced.edu ABSTRACT We propose a system that can accurately determine the oc- cupancy of zones within a building to a building's energy management system in order to control the Heating, Ventilation, Air Condition- ing, (HVAC

  13. Proceedings of Healthy Buildings 2009 Paper 535 HVAC filters as "passive" samplers: fate analysis of indoor particles

    E-Print Network [OSTI]

    Siegel, Jeffrey

    Proceedings of Healthy Buildings 2009 Paper 535 HVAC filters as "passive" samplers: fate analysis: fedenoris@mail.utexas.edu SUMMARY To assess the potential use of HVAC filters as passive indoor samplers, exfiltration, and capture in the HVAC filter. The results suggest that large particles are likely to deposit

  14. Nuclear Power - System Simulations and Operation 

    E-Print Network [OSTI]

    2011-01-01T23:59:59.000Z

    A&M University United States of America 1 Simulation and Simulators for Nuclear Power Generation J a n o s Sebe s ty e n Janos y MTA KFKI Atomic Energy Research Institute Hungary 1. Introduction T h i s chapte r deals with simula... t i o n , a very po werfu l tool in designi n g , constru c t i n g and operat i n g nuclea r power genera t i n g facili ti es . There are very differ e n t types of power plants , and the exampl e s mentio n e d in this chapte r or igin a t e from...

  15. Reactor Subsystem Simulation for Nuclear Hybrid Energy Systems

    SciTech Connect (OSTI)

    Shannon Bragg-Sitton; J. Michael Doster; Alan Rominger

    2012-09-01T23:59:59.000Z

    Preliminary system models have been developed by Idaho National Laboratory researchers and are currently being enhanced to assess integrated system performance given multiple sources (e.g., nuclear + wind) and multiple applications (i.e., electricity + process heat). Initial efforts to integrate a Fortran-based simulation of a small modular reactor (SMR) with the balance of plant model have been completed in FY12. This initial effort takes advantage of an existing SMR model developed at North Carolina State University to provide initial integrated system simulation for a relatively low cost. The SMR subsystem simulation details are discussed in this report.

  16. A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2

    E-Print Network [OSTI]

    A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2 3 4 Peng Xu, Philip Haves a library of equipment reference models developed for automated fault detection and diagnosis of secondary of automatic documentation methods in the library. INTRODUCTION The increasing complexity of building HVAC

  17. Recent Developments of the Modelica"Buildings" Library for Building Energy and Control Systems

    SciTech Connect (OSTI)

    Wetter, Michael; Zuo, Wangda; Nouidui, Thierry Stephane

    2011-04-01T23:59:59.000Z

    At the Modelica 2009 conference, we introduced the Buildings library, a freely available Modelica library for building energy and control systems. This paper reports the updates of the library and presents example applications for a range of heating, ventilation and air conditioning (HVAC) systems. Over the past two years, the library has been further developed. The number of HVAC components models has been doubled and various components have been revised to increase numerical robustness.The paper starts with an overview of the library architecture and a description of the main packages. To demonstrate the features of the Buildings library, applications that include multizone airflow simulation as well as supervisory and local loop control of a variable air volume (VAV) system are briefly described. The paper closes with a discussion of the current development.

  18. PowerSystemsSimulation NSERC Industrial Research Chair in

    E-Print Network [OSTI]

    Chaudhary, Sanjay

    an offshore wind power plant to an onshore grid. To develop a PSCAD/EMTDC simulation model of an offshore WPPPowerSystemsSimulation NSERC Industrial Research Chair in Legends: 1. Without negative sequence, Aalborg Univ. and Univ. of Manitoba, email:skc@et.aau.dk A 400MW offshore wind power plant has been

  19. Proton corebeam system in the expanding solar wind: Hybrid simulations

    E-Print Network [OSTI]

    California at Berkeley, University of

    Proton corebeam system in the expanding solar wind: Hybrid simulations Petr Hellinger1,2 and Pavel 9 November 2011. [1] Results of a twodimensional hybrid expanding box simulation of a proton to a decrease of the ratio between the proton perpendicular and parallel temperatures as well as to an increase

  20. System-Level Monitoring and Diagnosis of Building HVAC System

    E-Print Network [OSTI]

    Wu, Siyu

    2013-01-01T23:59:59.000Z

    setpoint may demand less cooling supply air. A fouled airsetpoint may demand less cooling supply air. A fouled airrequires more cooling or heating supply air from its upper-

  1. System-Level Monitoring and Diagnosis of Building HVAC System

    E-Print Network [OSTI]

    Wu, Siyu

    2013-01-01T23:59:59.000Z

    Y. Shu, Building envelope regulations on thermal comfort inof the building envelope on indoor thermal behavior, serveof the building envelope on indoor thermal behavior. This is

  2. Optimization of Ice Thermal Storage Systems Design for HVAC Systems

    E-Print Network [OSTI]

    Nassif, N.; Hall, C.; Freelnad, D.

    2013-01-01T23:59:59.000Z

    Ice thermal storage is promising technology to reduce energy costs by shifting the cooling cost from on-peak to off-peak periods. The paper discusses the optimal design of ice thermal storage and its impact on energy consumption, demand, and total...

  3. A Simulation Study of Demand Responsive Transit System Design

    E-Print Network [OSTI]

    Dessouky, Maged

    A Simulation Study of Demand Responsive Transit System Design Luca Quadrifoglio, Maged M. Dessouky changed the landscape for demand responsive transit systems. First, the demand for this type of transit experiencing increased usage for demand responsive transit systems. The National Transit Summaries and Trends

  4. Simulation Algorithms in Vehicle System Dynamics MARTIN ARNOLD

    E-Print Network [OSTI]

    , hydraulic and other system components [1, 2], see also [3] for a summary of recent developments and [4 an overview on classical and more advanced simu- lation algorithms in vehicle system dynamics that are closelySimulation Algorithms in Vehicle System Dynamics MARTIN ARNOLD SUMMARY Multi-body dynamics may

  5. Simulating sensorimotor systems with cortical topology 

    E-Print Network [OSTI]

    Saxon, James Bennett

    1991-01-01T23:59:59.000Z

    . And Dr. Shebilske, who introduced me to the other side of the loop, is also due many thanks. I would also like to thank the researchers of the Scientific Visualization Laboratory, Hassan Charara, Sandip Barua, Niels Konrad Bauer, and especially Sheng... for observing and present- ing this type of information, such as animation and high volume density plots, must be developed. 1. 1. 3. Reinvestigation of Kohonen Self-Organizing Network and the Neu- robot II Simulations Preliminary results in reinvestigating...

  6. Systems simulation of oil additives to grain at terminal elevators

    E-Print Network [OSTI]

    Goforth, Kerry James

    1985-01-01T23:59:59.000Z

    SYSTEMS SIMULATION OF OIL ADDITIVES TO GRAIN AT TERMINAL ELEVATORS A Thesis by Kerry James Goforth Submitted to the Graduate College of Texas A8M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE May... 1985 Major Subject: Agricultural Engineering SYSTEMS SIMULATION OF OIL ADDITIVES TO GRAIN AT TERMINAL ELEVATORS A Thesis by KERRY J. GOFORTH Approved as to style and content by: Calvin B. Parne 1, Jr. (Chairman of Committee) tto R. Kunze...

  7. Simulated performance of an airborne lidar wind shear detection system

    E-Print Network [OSTI]

    Griffith, Kenneth Scott

    1987-01-01T23:59:59.000Z

    SIMULATED PERFORMANCE OF AN AIRBORNE LIDAR WIND SHEAR DETECTION SYSTEM A Thesis by KENNETH SCOTT GRIFFITH Submitted to the Graduate College of Texas ASM University in partial fulfillment of the requirement for the degree of MASTER OF SCIENCE... December 1987 Major Subject: Physics SIMULATED PERFORMANCE OF AN AIRBORNE LIDAR WIND SHEAR DETECTION SYSTEM A Thesis by KENNETH SCOTT GRIFFITH Approved as to style and content by: e . atta ar (Chair an of Committee) T omas . air, III (Member) ic...

  8. Acceleration of the matrix multiplication of Radiance three phase daylighting simulations with parallel computing on heterogeneous hardware of personal computer

    SciTech Connect (OSTI)

    University of Miami; Zuo, Wangda; McNeil, Andrew; Wetter, Michael; Lee, Eleanor S.

    2013-04-30T23:59:59.000Z

    Building designers are increasingly relying on complex fenestration systems to reduce energy consumed for lighting and HVAC in low energy buildings. Radiance, a lighting simulation program, has been used to conduct daylighting simulations for complex fenestration systems. Depending on the configurations, the simulation can take hours or even days using a personal computer. This paper describes how to accelerate the matrix multiplication portion of a Radiance three-phase daylight simulation by conducting parallel computing on heterogeneous hardware of a personal computer. The algorithm was optimized and the computational part was implemented in parallel using OpenCL. The speed of new approach was evaluated using various daylighting simulation cases on a multicore central processing unit and a graphics processing unit. Based on the measurements and analysis of the time usage for the Radiance daylighting simulation, further speedups can be achieved by using fast I/O devices and storing the data in a binary format.

  9. LDV HVAC Model Development and Validation | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport(FactDepartment ofLetter Report:40PM to 2:05PMDOE-STD-1107-97LSEED:LDV HVAC Model

  10. Supercomputers model and simulate complex, dynamic systems

    Broader source: Energy.gov (indexed) [DOE]

    Laboratory System has built and deployed some of the most significant high-performance computing (HPC) resources available anywhere, including 32 of the 500 fastest...

  11. Dynamic simulation of a proposed ITER tritium processing system

    SciTech Connect (OSTI)

    Kuan, W.; Abdou, M.A. [Univ. of California, Los Angeles, CA (United States); Scott W.R. [Los Alamos National Lab., NM (United States)

    1995-10-01T23:59:59.000Z

    Dynamically simulating the fuel cycle in a fusion reactor is crucial to developing a better understanding of the safe and reliable operation of this complex system. In this work, we propose a tritium processing system for ITER`s plasma exhaust. The dynamic simulation of this proposed system is then performed with the TRUFFLES (TRitiUm Fusion Fuel cycLE dynamic Simulation) model. The fuel management, storage, and fueling operations are developed and coupled with previous cryopump and fuel cleanup unit subsystems to fully realize the complete torus exhaust flow cycle. Results show that tritium inventories will vary widely depending upon reactor operation, individual subsystem and unit operation designs. A diverse collection of batch-controlled subsystems with changes in their processing parameters are simulated in this work. In particular, the effects from the fuel management subsystem`s fuel reserve and tank switching times are quantified using sensitivity studies. 6 refs., 10 figs., 2 tabs.

  12. Kentucky Power- Residential Efficient HVAC Rebate Program

    Broader source: Energy.gov [DOE]

    Kentucky Power's High Efficiency Heat Pump Program offers a $400 rebate to residential customers living in existing (site-built) homes who upgrade electric resistance heating systems with a new,...

  13. Chapitre 8: Simulation for Product Driven Systems

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    of controlling production through traditional MRP² systems. hal-00341987,version1-26Nov2008 Author manuscript) 221-255" #12;There is a large consensus in the IMS community between holonic control, production to the planning function is based on the five steps Manufacturing Planning and Control System (MPCS) structure

  14. THE DISTRIBUTED SPACECRAFT ATTITUDE CONTROL SYSTEM SIMULATOR

    E-Print Network [OSTI]

    Hall, Christopher D.

    compensation of an under-actuated system and coupled attitude control and energy storage techniques. Formation. INTRODUCTION Complex space systems are often both high-visibility and high-risk. However, programs that might@vt.edu 1 #12;custom hardware and software we have developed. The body of the paper presents information

  15. Simulating sensorimotor systems with cortical topology

    E-Print Network [OSTI]

    Saxon, James Bennett

    1991-01-01T23:59:59.000Z

    Design. . . . Figure 9. The Brain Function . . Figure 10. Chaotic Behavior of a Simple Recurrent Equation of One Variable . . Page . . . . 13 . . . . 15 . . . . 1 6 24 . . . 25 Figure 11. Difference between Cartesian Image Space and Joint... intelli- gence and/or neural networks on the technological side and involve anatomical, physiological, and psychological systems on the biological side. We will characterize recent robotic sensorimotor system designs by comparing them from...

  16. Grundfos HVAC OEM Efficient water hydraulics

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    complexity ·20 years of experience in hydraulics for the Boiler System industry. ·Key success factor is our Benefits with an integrated solution #12;Heat pump unit with storage tank 1 2 Efficient water hydraulics 3 return Heatin g supply Cold wate r Hot water PRV Drain 3 way valve 1 2 3 air ventPT Grundfos flow sensor

  17. CALIFORNIA ENERGY Small HVAC Database Of Monitored

    E-Print Network [OSTI]

    , it is not individual building components, equipment, or materials that optimize energy efficiency. Instead, energy efficiency is improved through the integrated design, construction, and operation of building systems: Architectural Energy Corporation Pete Jacobs, Lead Author Boulder, Colorado Managed By: New Buildings Institute

  18. CALIFORNIA ENERGY Large HVAC Energy Impact Report

    E-Print Network [OSTI]

    , it is not individual building components, equipment, or materials that optimize energy efficiency. Instead, energy efficiency is improved through the integrated design, construction, and operation of building systems Buildings Institute Cathy Higgins, Program Director White Salmon, Washington CEC Contract No. 400

  19. CALIFORNIA ENERGY Small HVAC Problems and Potential

    E-Print Network [OSTI]

    , it is not individual building components, equipment, or materials that optimize energy efficiency. Instead, energy efficiency is improved through the integrated design, construction, and operation of building systems in Each Building (product 4.5.1) Statewide Energy Impact (product 4.5.3) TECHNICALREPORT October 2003 500

  20. Modelling and simulation of multidisciplinary dynamic systems Lead: A. Fakri.

    E-Print Network [OSTI]

    Baudoin, Geneviève

    Modelling and simulation of multidisciplinary dynamic systems Lead: A. Fakri. Permanent members: P. Integration of various engineering disciplines and the consideration of the dynamic control need a concurrent suited for the energy exchanges to study multidisciplinary dynamic engineering systems modelling. Our

  1. VALUE-ADDED SIMULATION OF HYBRID SYSTEMS Ian A. Hiskens

    E-Print Network [OSTI]

    Hiskens, Ian A.

    of real-world, hybrid dynamical systems are technically challenging. Con- sequently, simulation plays- sidered in Section 5. Conclusions are provided in Section 6. 2 Model Systems that exhibit intrinsic, 2000) that these specifications can be met by a model that consists of a set of differential

  2. High speed simulation of microprocessor systems using LTU dynamic binary translation 

    E-Print Network [OSTI]

    Jones, Daniel

    2010-01-01T23:59:59.000Z

    This thesis presents new simulation techniques designed to speed up the simulation of microprocessor systems. The advanced simulation techniques may be applied to the simulator class which employs dynamic binary translation ...

  3. HVAC Energy Recovery Design and Economic Evaluation

    E-Print Network [OSTI]

    Kinnier, R. J.

    1979-01-01T23:59:59.000Z

    . As shown in Chart 5, the power requirements to operate an energy recovery system are a significant factor in the economic evaluations of the project as well as the additional costs for auxiliary components. These extra costs must be included... in the overall feasibility analysis. Chart 5 - Auxiliary Components FAN TYPE SUPPLY EXHAUST STATIC PRESSURE EXCHANGER FAN FAN PUMP COMPRESSOR FILTERS CONTROLS REQUIREMENTS, IN WG SUPPLY EXHAUST STATIONARY ? ? ? 1 1.0- 2.0 l.0- 2.0 HEAT WHEEL HYGROSCOPIC...

  4. Final Technical Report "Multiscale Simulation Algorithms for Biochemical Systems"

    SciTech Connect (OSTI)

    Petzold, Linda R.

    2012-10-25T23:59:59.000Z

    Biochemical systems are inherently multiscale and stochastic. In microscopic systems formed by living cells, the small numbers of reactant molecules can result in dynamical behavior that is discrete and stochastic rather than continuous and deterministic. An analysis tool that respects these dynamical characteristics is the stochastic simulation algorithm (SSA, Gillespie, 1976), a numerical simulation procedure that is essentially exact for chemical systems that are spatially homogeneous or well stirred. Despite recent improvements, as a procedure that simulates every reaction event, the SSA is necessarily inefficient for most realistic problems. There are two main reasons for this, both arising from the multiscale nature of the underlying problem: (1) stiffness, i.e. the presence of multiple timescales, the fastest of which are stable; and (2) the need to include in the simulation both species that are present in relatively small quantities and should be modeled by a discrete stochastic process, and species that are present in larger quantities and are more efficiently modeled by a deterministic differential equation (or at some scale in between). This project has focused on the development of fast and adaptive algorithms, and the fun- damental theory upon which they must be based, for the multiscale simulation of biochemical systems. Areas addressed by this project include: (1) Theoretical and practical foundations for ac- celerated discrete stochastic simulation (tau-leaping); (2) Dealing with stiffness (fast reactions) in an efficient and well-justified manner in discrete stochastic simulation; (3) Development of adaptive multiscale algorithms for spatially homogeneous discrete stochastic simulation; (4) Development of high-performance SSA algorithms.

  5. Building a Web-Based Federated Simulation System with Jini and XML Xueqin Huang

    E-Print Network [OSTI]

    Miller, John A.

    Building a Web-Based Federated Simulation System with Jini and XML Xueqin Huang John A. Miller 415 the process of building complex collaborative simulation systems, reuse of existing simulation models-Based federated simulation system, a group of simulation models residing on different machines attached

  6. Building America Expert Meeting Report: Transitioning Traditional HVAC Contractors to Whole House Performance Contractors

    SciTech Connect (OSTI)

    Burdick, A.

    2011-10-01T23:59:59.000Z

    This report outlines findings resulting from a U.S. Department of Energy Building America expert meeting to determine how HVAC companies can transition from a traditional contractor status to a service provider for whole house energy upgrade contracting. IBACOS has embarked upon a research effort under the Building America Program to understand business impacts and change management strategies for HVAC companies. HVAC companies can implement these strategies in order to quickly transition from a 'traditional' heating and cooling contractor to a service provider for whole house energy upgrade contracting. Due to HVAC service contracts, which allow repeat interaction with homeowners, HVAC companies are ideally positioned in the marketplace to resolve homeowner comfort issues through whole house energy upgrades. There are essentially two primary ways to define the routes of transition for an HVAC contractor taking on whole house performance contracting: (1) Sub-contracting out the shell repair/upgrade work; and (2) Integrating the shell repair/upgrade work into their existing business. IBACOS held an Expert Meeting on the topic of Transitioning Traditional HVAC Contractors to Whole House Performance Contractors on March 29, 2011 in San Francisco, CA. The major objectives of the meeting were to: Review and validate the general business models for traditional HVAC companies and whole house energy upgrade companies Review preliminary findings on the differences between the structure of traditional HVAC Companies and whole house energy upgrade companies Seek industry input on how to structure information so it is relevant and useful for traditional HVAC contractors who are transitioning to becoming whole house energy upgrade contractors Seven industry experts identified by IBACOS participated in the session along with one representative from the National Renewable Energy Laboratory (NREL). The objective of the meeting was to validate the general operational profile of an integrated whole house performance contracting company and identify the most significant challenges facing a traditional HVAC contractor looking to transition to a whole house performance contractor. To facilitate the discussion, IBACOS divided the business operations profile of a typical integrated whole house performance contracting company (one that performs both HVAC and shell repair/upgrade work) into seven Operational Areas with more detailed Business Functions and Work Activities falling under each high-level Operational Area. The expert panel was asked to review the operational profile or 'map' of the Business Functions. The specific Work Activities within the Business Functions identified as potential transition barriers were rated by the group relative to the value in IBACOS creating guidance ensuring a successful transition and the relative difficulty in executing.

  7. Simulation and simplified design studies of photovoltaic systems

    SciTech Connect (OSTI)

    Evans, D.L.; Facinelli, W.A.; Koehler, L.P.

    1980-09-01T23:59:59.000Z

    Results of TRNSYS simulations of photovoltaic systems with electrical storage are described. Studies of the sensitivity of system performance, in terms of the fraction of the electrical load supplied by the solar energy system, to variables such as array size, battery size, location, time of year, and load shape are reported. An accurate simplified method for predicting array output of max-power photovoltaic systems is presented. A second simplified method, which estimates the overall performance of max-power systems, is developed. Finally, a preliminary technique for predicting clamped-voltage system performance is discussed.

  8. Nuclear Systems Modeling, Simulation & Validation | ORNL

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for Renewable Energy:Nanowire3627 Federal Register /76SafeguardsSystems Modeling and

  9. Diagnosis of Effectiveness of HVAC System and Energy Performance of Osaka-Gas Building through Retro-Commissioning Part 2 Handling the Data Produced by BEMS and Some Results of Analyses

    E-Print Network [OSTI]

    Yamaha, M.; Ando,T.

    2014-01-01T23:59:59.000Z

    . Operation patterns of heat source plants vary from 2003 to 2012 according to change in plant’s operational strategy. 90 percent of primary energy was consumed by generators and chillers. Since the plant is run by combined heat and power system, waste... heat from the generators is recovered and used for chillers. The efficiency of the generators had been kept around 0.35 which was almost same as specification of the machines. The efficiency of the entire system, however, was decreased, especially...

  10. Long-term system dynamics simulation methods. Final report

    SciTech Connect (OSTI)

    Manke, J.W.; Pauly, W.R.; Hemmaplardh, K.

    1985-02-01T23:59:59.000Z

    The focus of long-term dynamic simulations is to analyze the effects of wide excursions of voltage, frequency and power flows for extended periods of time on the bulk power system. The emphasis on modeling the sequence of system events over an extended period of time that follows a major disturbance distinguishes long-term dynamics from transient and midterm stability analysis where the effects of inter-machine oscillations on synchronous machines is the primary focus. The assumption of a uniform system frequency during quiscent system conditions makes it possible to use a numerical stepsize of one or more seconds for long-term studies, as opposed to a fraction of a cycle for transient/midterm stability, and to simulate the voltage and frequency effects of such system events as automatic load shedding and unit tripping for long periods of time. Both the time frame and the type of system events of interest in long-term dynamic studies establish the modeling and simulation requirements for a long-term program and the need for system data to validate the models and program. The sequence of system events that occur during the long-term time frame may introduce step changes in the system, i.e., load shedding, which cause transients that must be modeled on the transient stability time scale. This is the basis for the requirements that a long-term program have an adequate interface with a transient stability program.

  11. Joint HVAC transmission EMF environmental study

    SciTech Connect (OSTI)

    Stormshak, F.; Thompson, J. (Oregon State Univ., Corvallis, OR (United States))

    1992-05-01T23:59:59.000Z

    This document describes the rationale, procedures, and results of a carefully controlled study conducted to establish whether chronic exposure of female (ewe) Suffolk lambs to the environment of a 500-kV 60-Hz transmission line would affect various characteristics of growth, endocrine function, and reproductive development. This experiment used identical housing and management schemes for control and line-exposed ewes, thus minimizing these factors as contributors to between-group experimental error. Further, throughout the 10-month duration of this study, changes in electric and magnetic fields, audible noise, and weather conditions were monitored continuously by a computerized system. Such measurements provided the opportunity to identify any relationship between environmental factors and biological responses. Because of reports in the literature that electric and magnetic fields alter concentrations of melatonin in laboratory animals, the primary objective of this study was to ascertain whether a similar effect occurs in lambs exposed to a 500-kV a-c line in a natural setting. In addition, onset of puberty, changes in body weight, wool growth, and behavior were monitored. To determine whether the environment of a 500-kV line caused stress in the study animals, serum levels of cortisol were measured. The study was conducted at Bonneville Power Administration's Ostrander Substation near Estacada, Oregon.

  12. Nuclear Power - System Simulations and Operation

    E-Print Network [OSTI]

    5 w o r s e . It is impos s i bl e to set a valve or contr o l rod to an exact posit i o n if the time resol u t i o n of these inputs is only one second or even 0.2 second. It can happen that the new valve posit i o n is calcul a t e d only once... and the old I&C model s calcul a t e the contr o l parame t e r s (e.g. contro l valv e and rod pos i ti ons ) governi ng the tec hnol o gi c al mod els . The developme n t of the new system is made in four cons ec uti v e steps. 1. T h e new contr o l l e...

  13. UNIT NUMBER: C-304 Buildina/HVAC Picina Svstem- Soil Backfill

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    63 UNIT NUMBER: C-304 BuildinaHVAC Picina Svstem- Soil Backfill UNIT NAME: REGULATORY STATUS: AOC .OCATION: Adjacent to C-304 building APPROXIMATE DIMENSIONS: 100 feet wide by 200...

  14. Fast prototyping and Indirect Adaptive GPC temperature control of a class of passive HVAC

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Fast prototyping and Indirect Adaptive GPC temperature control of a class of passive HVAC TAWEGOUM (temperature, moisture) is a dominating factor, on the one hand to deal with the market quantitative

  15. What are the Best HVAC Solutions for Low-Load, High Performance Homes?"

    Broader source: Energy.gov [DOE]

    This presentation was given at the Summer 2012 DOE Building America meeting on July 26, 2012, and addressed the question What are the best HVAC solutions for low-load, high performance homes?"

  16. Particle loading rates for HVAC filters, heat exchangers, and ducts Nomenclature

    E-Print Network [OSTI]

    Siegel, Jeffrey

    particle mass emission rate distribution func- tion for resuspension (mg/lm h) Es particle mass emission The results in this paper suggest important factors that lead to particle deposition on HVAC components

  17. Systems and methods for controlling energy use in a building management system using energy budgets

    DOE Patents [OSTI]

    Wenzel, Michael J; Drees, Kirk H

    2014-09-23T23:59:59.000Z

    Systems and methods for limiting power consumption by a heating, ventilation, and air conditioning (HVAC) subsystem of a building are shown and described. A feedback controller is used to generate a manipulated variable based on an energy use setpoint and a measured energy use. The manipulated variable may be used for adjusting the operation of an HVAC device.

  18. Analysis of the Energy Savings Potential in K-5 Schools in Hot and Humid Climates: Application of High Performance Measures and Renewable Energy Systems

    E-Print Network [OSTI]

    Im, P.; Haberl, J.

    -08-05 of the building. Since the DOE-2 simulation program is not capable of simulating solar thermal and PV systems, the F-Chart and PV F-Chart program were used to calculate the hot water and the electricity generation from a solar thermal and PV system... measures were applied to the target building. Those measures include: increased glazing U-value, VFD application for the HVAC system, cold deck reset, variable speed for pumps, high-efficiency boiler, skylights, and the application of solar thermal...

  19. Performance simulation of a MRPC-based PET Imaging System

    E-Print Network [OSTI]

    A. Banerjee; S. Chattopadhyay

    2011-06-29T23:59:59.000Z

    The low cost and high resolution gas-based Multi-gap Resistive Plate Chamber (MRPC) opens a new possibility to find an efficient alternative detector for Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the system depends largely on the time resolution of the detector. Suitable converters can be used to increase the efficiency of detection of photons from annihilation. In this work, we perform a detailed GEANT4 simulation to optimize the converter thickness thereby improving the efficiency of photon conversion. Also we have developed a Monte Carlo based simulation of MRPC response thereby obtaining the intrinsic time resolution of the detector, making it possible to simulate the final response of MRPC-based systems for PET imaging. The result of the cosmic ray test of a four-gap Bakelite-based MRPC operating in streamer mode is discussed.

  20. Simulated, Emulated, and Physical Investigative Analysis (SEPIA) of networked systems.

    SciTech Connect (OSTI)

    Burton, David P.; Van Leeuwen, Brian P.; McDonald, Michael James; Onunkwo, Uzoma A.; Tarman, Thomas David; Urias, Vincent E.

    2009-09-01T23:59:59.000Z

    This report describes recent progress made in developing and utilizing hybrid Simulated, Emulated, and Physical Investigative Analysis (SEPIA) environments. Many organizations require advanced tools to analyze their information system's security, reliability, and resilience against cyber attack. Today's security analysis utilize real systems such as computers, network routers and other network equipment, computer emulations (e.g., virtual machines) and simulation models separately to analyze interplay between threats and safeguards. In contrast, this work developed new methods to combine these three approaches to provide integrated hybrid SEPIA environments. Our SEPIA environments enable an analyst to rapidly configure hybrid environments to pass network traffic and perform, from the outside, like real networks. This provides higher fidelity representations of key network nodes while still leveraging the scalability and cost advantages of simulation tools. The result is to rapidly produce large yet relatively low-cost multi-fidelity SEPIA networks of computers and routers that let analysts quickly investigate threats and test protection approaches.

  1. Three-Dimensional Magnetohydrodynamic Simulation of Slapper Initiation Systems

    SciTech Connect (OSTI)

    Christensen, J S; Hrousis, C A

    2010-03-09T23:59:59.000Z

    Although useful information can be gleaned from 2D and even 1D simulations of slapper type initiation systems, these systems are inherently three-dimensional and therefore require full 3D representation to model all relevant details. Further, such representation provides additional insight into optimizing the design of such devices from a first-principles perspective and can thereby reduce experimental costs. We discuss in this paper several ongoing efforts in modeling these systems, our pursuit of validation, and extension of these methods to other systems. Our results show the substantial dependence upon highly accurate global equations of state and resistivity models in these analyses.

  2. Modeling the Arterial System with Reference to an Anesthesia Simulator

    E-Print Network [OSTI]

    Olufsen, Mette Sofie

    Modeling the Arterial System with Reference to an Anesthesia Simulator Ph.D. Thesis 1 by Mette), and at the Department of Anesthesia, Herlev University Hospital. The study has been organized as an industrial Ph S.A. Pedersen, Roskilde University, and M.D. P.F. Jensen, Ph.D., Department of Anesthesia, Herlev

  3. Simulation of the TREAT-Upgrade Automatic Reactor Control System

    SciTech Connect (OSTI)

    Lipinski, W.C.; Kirsch, L.W.; Valente, A.D.

    1984-01-01T23:59:59.000Z

    This paper describes the design of the Automatic Reactor Control System (ARCS) for the Transient Reactor Test Facility (TREAT) Upgrade. A simulation was used to facilitate the ARCS design and to completely test and verify its operation before installation at the TREAT facility.

  4. Design, Analysis, and Simulation of Rocket Propulsion System

    E-Print Network [OSTI]

    Kulhanek, Sarah Logan

    2012-08-31T23:59:59.000Z

    . The program currently provides a symbolic link in the form of a button on the output page which will open Unigraphics NX CAD program. The post-processing simulation of the rocket propulsion system is done in a computational fluid dynamics (CFD) program...

  5. Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1

    E-Print Network [OSTI]

    Johnson, F.X.

    2010-01-01T23:59:59.000Z

    Administration. April. EPRI. 1982. Residential End-UseInstitute. EA-2512. July. EPRI. 1990. REEPS 2.0 HVAC ModelInstitute. October 11. EPRI, Electric Power Research

  6. Big Data Visual Analytics for Exploratory Earth System Simulation Analysis

    SciTech Connect (OSTI)

    Steed, Chad A [ORNL; Ricciuto, Daniel M [ORNL; Shipman, Galen M [ORNL; Smith, Brian E [ORNL; Thornton, Peter E [ORNL; Wang, Dali [ORNL; Shi, Xiaoying [ORNL; Williams, Dean N. [Lawrence Livermore National Laboratory (LLNL)

    2013-01-01T23:59:59.000Z

    Rapid increases in high performance computing are feeding the development of larger and more complex data sets in climate research, which sets the stage for so-called big data analysis challenges. However, conventional climate analysis techniques are inadequate in dealing with the complexities of today s data. In this paper, we describe and demonstrate a visual analytics system, called the Exploratory Data analysis ENvironment (EDEN), with specific application to the analysis of complex earth system simulation data sets. EDEN represents the type of interactive visual analysis tools that are necessary to transform data into insight, thereby improving critical comprehension of earth system processes. In addition to providing an overview of EDEN, we describe real-world studies using both point ensembles and global Community Land Model Version 4 (CLM4) simulations.

  7. Large-scale simulations of complex physical systems

    SciTech Connect (OSTI)

    Belic, A. [Scientific Computing Laboratory, Institute of Physics, Pregrevica 118, 11080 Belgrade (Serbia and Montenegro)

    2007-04-23T23:59:59.000Z

    Scientific computing has become a tool as vital as experimentation and theory for dealing with scientific challenges of the twenty-first century. Large scale simulations and modelling serve as heuristic tools in a broad problem-solving process. High-performance computing facilities make possible the first step in this process - a view of new and previously inaccessible domains in science and the building up of intuition regarding the new phenomenology. The final goal of this process is to translate this newly found intuition into better algorithms and new analytical results.In this presentation we give an outline of the research themes pursued at the Scientific Computing Laboratory of the Institute of Physics in Belgrade regarding large-scale simulations of complex classical and quantum physical systems, and present recent results obtained in the large-scale simulations of granular materials and path integrals.

  8. Generic solar photovoltaic system dynamic simulation model specification.

    SciTech Connect (OSTI)

    Ellis, Abraham; Behnke, Michael Robert; Elliott, Ryan Thomas

    2013-10-01T23:59:59.000Z

    This document is intended to serve as a specification for generic solar photovoltaic (PV) system positive-sequence dynamic models to be implemented by software developers and approved by the WECC MVWG for use in bulk system dynamic simulations in accordance with NERC MOD standards. Two specific dynamic models are included in the scope of this document. The first, a Central Station PV System model, is intended to capture the most important dynamic characteristics of large scale (> 10 MW) PV systems with a central Point of Interconnection (POI) at the transmission level. The second, a Distributed PV System model, is intended to represent an aggregation of smaller, distribution-connected systems that comprise a portion of a composite load that might be modeled at a transmission load bus.

  9. Simulation system provides unique training method for the oilfield

    SciTech Connect (OSTI)

    Beck, K. [Halliburton Energy Service, Dallas, TX (United States). Dallas Technology Center; Schwendemann, K. [Halliburton Energy Service, Carrollton, TX (United States). Dallas/Fort Worth Technology Center

    1997-02-01T23:59:59.000Z

    Integrated services and turnkey operations are becoming the norm for the industry, and oilfield service companies are finding themselves linked with operators and contractors in long-term service contracts that would never have been considered in the 1980`s. In this paper, the authors discuss a unique simulator that can resolve the training needs that have surfaced as a result of the rapidly changing operational concepts in the oilfield environment. They will present the concepts of the equipment simulator and capabilities of the global simulator methodology, and they will use an actual case history to describe in detail how the equipment simulator was used offshore on a recent well-test job in the Gulf Coast area to introduce a new well-test tool and to train a new design engineer. With this information, the authors conclude that the use of the simulator will provide unparalleled training support for oilfield equipment and system applications and facilitate efficient development of integrated solutions for oilfield projects.

  10. Decentralized model predictive control of a multiple evaporator HVAC system

    E-Print Network [OSTI]

    Elliott, Matthew Stuart

    2009-05-15T23:59:59.000Z

    separate body of water, referred to as a cooling zone. The two evaporators are connected to a single condenser and variable speed compressor, and feature variable water flow and electronic expansion valves. The control problem lies in development of a...

  11. Model-Based Hierarchical Optimal Control Design for HVAC Systems

    E-Print Network [OSTI]

    Maasoumy, Mehdi; Pinto, Alessandro; Sangiovanni-Vincentelli, Alberto

    2014-01-01T23:59:59.000Z

    sun on the external sides of the walls in deriving the differential equations of the temperature distribution

  12. The Application of Ultraviolet Germicidal Technology in HVAC Systems

    E-Print Network [OSTI]

    Taylor, M. J.

    2000-01-01T23:59:59.000Z

    capability, which increases the operating costs of the equipment. Fortunately, IAQ degradation, foul odor, and increased expenses can be eliminated with the installation of the ultraviolet 'C' band (W-C) lamps. The ultraviolet germicidal lamps are designed...

  13. Multi-Sensor Single-Actuator Control of HVAC Systems 

    E-Print Network [OSTI]

    Lin, C.; Auslander, D.; Federspiel, C.

    2002-01-01T23:59:59.000Z

    It is common to control several rooms in a building with a single sensor in one of the rooms and a single actuator driving just one control element such as an air damper. New, low-cost, wireless sensor technology now offers the opportunity...

  14. Multi-Sensor Single-Actuator Control of HVAC Systems

    E-Print Network [OSTI]

    Lin, C.; Auslander, D.; Federspiel, C.

    2002-01-01T23:59:59.000Z

    It is common to control several rooms in a building with a single sensor in one of the rooms and a single actuator driving just one control element such as an air damper. New, low-cost, wireless sensor technology now offers the opportunity...

  15. Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems

    E-Print Network [OSTI]

    Najafi, Massieh

    2010-01-01T23:59:59.000Z

    methods. Computers in Chemical Engineering, 2003, vol. 27,Computers in Chemical Engineering, 2003, vol. 27, pp. 313-methods. Computers in Chemical Engineering, 2003, vol. 27,

  16. Software for fault detection in HVAC systems in commercial buildings

    E-Print Network [OSTI]

    Deshmukh, Suhrid Avinash

    2014-01-01T23:59:59.000Z

    The building sector of the United States currently consumes over 41% of the United States primary energy supply. Estimates suggest that between 5 and 30% of any building's annual energy consumption is unknowingly wasted ...

  17. Comparison of emerging diagnostic tools for large commercial HVAC systems

    E-Print Network [OSTI]

    Friedman, Hannah; Piette, Mary Ann

    2001-01-01T23:59:59.000Z

    Tool UT (PG&E) WBE WBD OA/E PACRAT EEM Suite IMDS/ ElectricUT (PG&E) WBE WBD OA/E PACRAT EEM Suite Note 1: The user canDiagnostics from DDC Data PACRAT,” Proceedings of the 8 th

  18. Evaluation of Emerging Diagnostic Tools for Commercial HVAC Systems

    E-Print Network [OSTI]

    Friedman, H.; Piette, M. A.

    2001-01-01T23:59:59.000Z

    six tools in our analysis: Architectural Energy Corporation's ENFORMA? software, Facility Dynamics Engineering's Performance And Continuous Re-commissioning Analysis Tool (PACRAT), Pacific Northwest National Laboratory's Whole Building Diagnostician...

  19. Integration of HVAC System Design with Simplified Duct Distribution -

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreaking of BlytheDepartmentEnergy Integrated EnergyIntegratedAdaptingBuilding

  20. enVerid Systems - HVAC Load Reduction | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn AprilA group currentBradleyTable of Contents: A NoteAPPENDIX I

  1. Energy Efficient HVAC System for Distributed Cooling/Heating with

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny:RevisedAdvisoryStandard |in STEMEnergyI.of Energy EnergyPrecipitator

  2. The Development of A Human Systems Simulation Laboratory: Strategic Direction

    SciTech Connect (OSTI)

    Jacques Hugo; Katya le Blanc; David Gertman

    2012-07-01T23:59:59.000Z

    The Human System Simulation Laboratory (HSSL) at the Idaho National Laboratory is one of few facilities of its kind that allows human factors researchers to evaluate various aspects of human performance and human system interaction for proposed reactor designs and upgrades. A basic system architecture, physical configuration and simulation capability were established to enable human factors researchers to support multiple, simultaneous simulations and also different power plant technologies. Although still evolving in terms of its technical and functional architecture, the HSSL is already proving its worth in supporting current and future nuclear industry needs for light water reactor sustainability and small modular reactors. The evolution of the HSSL is focused on continual physical and functional refinement to make it a fully equipped, reconfigurable facility where advanced research, testing and validation studies can be conducted on a wider range of reactor technologies. This requires the implementation of additional plant models to produce empirical research data on human performance with emerging human-system interaction technologies. Additional beneficiaries of this information include system designers and HRA practitioners. To ensure that results of control room crew studies will be generalizable to the existing and evolving fleet of US reactors, future expansion of the HSSL may also include other SMR plant models, plant-specific simulators and a generic plant model aligned to the current generation of pressurized water reactors (PWRs) and future advanced reactor designs. Collaboration with industry partners is also proving to be a vital component of the facility as this helps to establish a formal basis for current and future human performance experiments to support nuclear industry objectives. A long-range Program Plan has been developed for the HSSL to ensure that the facility will support not only the Department of Energy’s Light Water Reactor Sustainability Program, but also to provide human factors guidance for all future developments of the nuclear industry.

  3. An Integrated System Simulation Approach for Wireless Networked Control Systems

    E-Print Network [OSTI]

    Koutsoukos, Xenofon D.

    Vanderbilt University Nashville, TN, USA Abstract--Cyber-Physical Systems (CPS), such as networked control wireless networks. Accurate modeling of these communication networks is essential in the design and verification of CPS. Controller design needs to take into ac- count the wireless channel characteristics (e

  4. A graphical electromagnetic simulation laboratory for power systems engineering programs

    SciTech Connect (OSTI)

    Gole, A.M. [Univ. of Manitoba, Winnipeg, Manitoba (Canada)] [Univ. of Manitoba, Winnipeg, Manitoba (Canada); Nayak, O.B. [Manitoba HVDC Research Centre, Winnipeg, Manitoba (Canada)] [Manitoba HVDC Research Centre, Winnipeg, Manitoba (Canada); Sidhu, T.S.; Sachdev, M.S. [Univ. of Saskatchewan, Saskatoon, Saskatchewan (Canada)] [Univ. of Saskatchewan, Saskatoon, Saskatchewan (Canada)

    1996-05-01T23:59:59.000Z

    The recent availability of Electromagnetic Transient Programs with graphical front ends now makes it possible to put together models for circuits and systems in a manner similar to the connection of components in a laboratory. In the past, the non-graphical EMT Programs required considerable expertise in their use and thus distracted the students into the details or simulation. The introduction of a graphical simulation based laboratory into Undergraduate and Graduate Engineering Programs is presented, based on the PSCAD/EMTDC program. The philosophy behind the design of suitable example cases is presented within the framework of an Undergraduate Power Electronics Course, an HVdc Transmission Course and a course on Power System Protection.

  5. CLARREO shortwave observing system simulation experiments of the twenty-first century: Simulator design and implementation

    SciTech Connect (OSTI)

    Feldman, D.R.; Algieri, C.A.; Ong, J.R.; Collins, W.D.

    2011-04-01T23:59:59.000Z

    Projected changes in the Earth system will likely be manifested in changes in reflected solar radiation. This paper introduces an operational Observational System Simulation Experiment (OSSE) to calculate the signals of future climate forcings and feedbacks in top-of-atmosphere reflectance spectra. The OSSE combines simulations from the Intergovernmental Panel on Climate Change (IPCC) Fourth Assessment Report for the NCAR Community Climate System Model (CCSM) with the MODTRAN radiative transfer code to calculate reflectance spectra for simulations of current and future climatic conditions over the 21st century. The OSSE produces narrowband reflectances and broadband fluxes, the latter of which have been extensively validated against archived CCSM results. The shortwave reflectance spectra contain atmospheric features including signals from water vapor, liquid and ice clouds, and aerosols. The spectra are also strongly influenced by the surface bidirectional reflectance properties of predicted snow and sea ice and the climatological seasonal cycles of vegetation. By comparing and contrasting simulated reflectance spectra based on emissions scenarios with increasing projected and fixed present-day greenhouse gas and aerosol concentrations, we find that prescribed forcings from increases in anthropogenic sulfate and carbonaceous aerosols are detectable and are spatially confined to lower latitudes. Also, changes in the intertropical convergence zone and poleward shifts in the subsidence zones and the storm tracks are all detectable along with large changes in snow cover and sea ice fraction. These findings suggest that the proposed NASA Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission to measure shortwave reflectance spectra may help elucidate climate forcings, responses, and feedbacks.

  6. A Study of mixing in computer simulated laminar flow systems 

    E-Print Network [OSTI]

    McFarland, Allison Anne

    1984-01-01T23:59:59.000Z

    1984 Major Subject: Chemical Engineering A STUDY OF MIXING IN COMPUTER SIMULATED LAMINAR FLOW SYSTEMS A Thesis by ALLISON ANNE MCFARLAND Approved as to style and content by: Gary B. Tatterson (Chairman) ries J. Glover (Member) A. Ted Watson...: Dr. Gary B. Tatterson Mixing is a process that reduces nonuniformities or gradients in composition, properties, or temperature of material in bulk. It is a basic part of many chemical engineering processes, yet the theoretical understanding...

  7. SYSTEM PLANNING WITH THE HANFORD WASTE OPERATIONS SIMULATOR

    SciTech Connect (OSTI)

    CRAWFORD TW; CERTA PJ; WELLS MN

    2010-01-14T23:59:59.000Z

    At the U. S. Department of Energy's Hanford Site in southeastern Washington State, 216 million liters (57 million gallons) of nuclear waste is currently stored in aging underground tanks, threatening the Columbia River. The River Protection Project (RPP), a fully integrated system of waste storage, retrieval, treatment, and disposal facilities, is in varying stages of design, construction, operation, and future planning. These facilities face many overlapping technical, regulatory, and financial hurdles to achieve site cleanup and closure. Program execution is ongoing, but completion is currently expected to take approximately 40 more years. Strategic planning for the treatment of Hanford tank waste is by nature a multi-faceted, complex and iterative process. To help manage the planning, a report referred to as the RPP System Plan is prepared to provide a basis for aligning the program scope with the cost and schedule, from upper-tier contracts to individual facility operating plans. The Hanford Tank Waste Operations Simulator (HTWOS), a dynamic flowsheet simulation and mass balance computer model, is used to simulate the current planned RPP mission, evaluate the impacts of changes to the mission, and assist in planning near-term facility operations. Development of additional modeling tools, including an operations research model and a cost model, will further improve long-term planning confidence. The most recent RPP System Plan, Revision 4, was published in September 2009.

  8. A Virtual Engineering Framework for Simulating Advanced Power System

    SciTech Connect (OSTI)

    Mike Bockelie; Dave Swensen; Martin Denison; Stanislav Borodai

    2008-06-18T23:59:59.000Z

    In this report is described the work effort performed to provide NETL with VE-Suite based Virtual Engineering software and enhanced equipment models to support NETL's Advanced Process Engineering Co-simulation (APECS) framework for advanced power generation systems. Enhancements to the software framework facilitated an important link between APECS and the virtual engineering capabilities provided by VE-Suite (e.g., equipment and process visualization, information assimilation). Model enhancements focused on improving predictions for the performance of entrained flow coal gasifiers and important auxiliary equipment (e.g., Air Separation Units) used in coal gasification systems. In addition, a Reduced Order Model generation tool and software to provide a coupling between APECS/AspenPlus and the GE GateCycle simulation system were developed. CAPE-Open model interfaces were employed where needed. The improved simulation capability is demonstrated on selected test problems. As part of the project an Advisory Panel was formed to provide guidance on the issues on which to focus the work effort. The Advisory Panel included experts from industry and academics in gasification, CO2 capture issues, process simulation and representatives from technology developers and the electric utility industry. To optimize the benefit to NETL, REI coordinated its efforts with NETL and NETL funded projects at Iowa State University, Carnegie Mellon University and ANSYS/Fluent, Inc. The improved simulation capabilities incorporated into APECS will enable researchers and engineers to better understand the interactions of different equipment components, identify weaknesses and processes needing improvement and thereby allow more efficient, less expensive plants to be developed and brought on-line faster and in a more cost-effective manner. These enhancements to APECS represent an important step toward having a fully integrated environment for performing plant simulation and engineering. Furthermore, with little effort the modeling capabilities described in this report can be extended to support other DOE programs, such as ultra super critical boiler development, oxy-combustion boiler development or modifications to existing plants to include CO2 capture and sequestration.

  9. Simulation of the treat-upgrade automatic reactor control system

    SciTech Connect (OSTI)

    Lipinski, W.C.; Kirsch, L.W.; Valente, A.D.

    1985-02-01T23:59:59.000Z

    This paper describes the design of the Automatic Reactor Control System (ARCS) for the Transient Reactor Test Facility (TREAT) Upgrade. A simulation was used to facilitate the ARCS design, and to completely test and verify its operation before installation at the TREAT facility. The ARCS is a microprocessor network based closed loop control system that provides a position demand control signal to the transient rod hydraulic drive system. There are four identical servo-hydraulic rod drives and each operates as a position control system. The ARCS updates its position demand control signal every 1 msec and its function is to control the transient rods so that the reactor follows a prescribed power-time profile (planned transient). The Main Control Algorithm (MCA) for the ARCS is an optimal reactivity demand algorithm. At each time step, the MCA generates a set of reference reactor functions, e.g., power, period, energy, and delayed neutron power. These functions are compared to plant measurements and estimated values at each time step and are operated on by appropriate algorithms to generate the reactivity demand function. The data necessary to calculate the reference functions is supplied from a Transient Prescription Control Data Set (TPCDS). The TPCDS specifies the planned transient as a fixed number of simply connected independent power profile segments. The developed simulation code models the TREAT reactor kinetics, the hydraulic rod drive system, the plant measurement system, and the ARCS control processor MCA. All of the models operate as continuous systems with the exception of the MCA which operates as a discrete time system at fixed multiples of 1 msec. The study indicates that the ARCS will meet or exceed all of its design specifications.

  10. Comparison Between TRNSYS Software Simulation and PV F-Chart Program on Photovoltaic System

    E-Print Network [OSTI]

    Haberl, J. S.; Baltazar, J. C.; Mao, C.

    2012-01-01T23:59:59.000Z

    This report covers the comparisons of Photovoltaic System by TRNSYS simulation and PV F-Chart program to test TRNSYS simulation accuracy. The report starts with the Photovoltaic (PV) (PV) System introduction in Section one which is followed...

  11. Development of Design and Simulation Tool for Hybrid Geothermal Heat Pump System

    Broader source: Energy.gov [DOE]

    This project will expand Expand eQUEST, a building energy analysis software with latest implementation of DOE-2, for simulations of HGSHP systems and improve its existing simulation capabilities for ordinary GSHP systems.

  12. Comparison Between TRNSYS Software Simulation and PV F-Chart Program on Photovoltaic System 

    E-Print Network [OSTI]

    Haberl, J. S.; Baltazar, J. C.; Mao, C.

    2012-01-01T23:59:59.000Z

    This report covers the comparisons of Photovoltaic System by TRNSYS simulation and PV F-Chart program to test TRNSYS simulation accuracy. The report starts with the Photovoltaic (PV) (PV) System introduction in Section one which is followed...

  13. Uncalibrated Building Energy Simulation Modeling Results 

    E-Print Network [OSTI]

    Ahmad, M.; Culp, C.H.

    2006-01-01T23:59:59.000Z

    VOLUME 12, NUMBER 4 HVAC&R RESEARCH OCTOBER 2006 1141 Uncalibrated Building Energy Simulation Modeling Results Mushtaq Ahmad Charles H. Culp, PhD, PE Associate Member ASHRAE Fellow ASHRAE Received June 23, 2005; accepted April 17, 2006... the uncalibrated simulations were completed. The dis- crepancies between the simulated and measured total yearly building energy use varied over ±30% with one outlier. The results show that discrepancies ranged over ±90% between the sim- ulations and the measured...

  14. Spreader-Bar Radiation Detection System Enhancements: A Modeling and Simulation Study

    SciTech Connect (OSTI)

    Ely, James H.; Ashbaker, Eric D.; Batdorf, Michael T.; Baciak, James E.; Hensley, Walter K.; Jarman, Kenneth D.; Robinson, Sean M.; Sandness, Gerald A.; Schweppe, John E.

    2012-11-13T23:59:59.000Z

    This report provides the modeling and simulation results of the investigation of enhanced spreader bar radiation detection systems.

  15. Simulations of strongly phase-separated liquid-gas systems

    E-Print Network [OSTI]

    A. J. Wagner; C. M. Pooley

    2006-08-22T23:59:59.000Z

    Lattice Boltzmann simulations of liquid-gas systems are believed to be restricted to modest density ratios of less than 10. In this article we show that reducing the speed of sound and, just as importantly, the interfacial contributions to the pressure allows lattice Boltzmann simulations to achieve high density ratios of 1000 or more. We also present explicit expressions for the limits of the parameter region in which the method gives accurate results. There are two separate limiting phenomena. The first is the stability of the bulk liquid phase. This consideration is specific to lattice Boltzmann methods. The second is a general argument for the interface discretization that applies to any diffuse interface method.

  16. Improved Building Energy Performance Modelling through Comparison of Measured Data with Simulated Results 

    E-Print Network [OSTI]

    Bambrook, S.; Jacob, D.

    2008-01-01T23:59:59.000Z

    -ICE for the same building. The dataset collected at the demonstration building consists of total energy consumption, weather data, indoor conditions and HVAC system parameters, measured in at least hourly time steps. This paper presents the first steps in modelling...

  17. Improved Building Energy Performance Modelling through Comparison of Measured Data with Simulated Results

    E-Print Network [OSTI]

    Bambrook, S.; Jacob, D.

    -ICE for the same building. The dataset collected at the demonstration building consists of total energy consumption, weather data, indoor conditions and HVAC system parameters, measured in at least hourly time steps. This paper presents the first steps in modelling...

  18. THE ROLE OF CLOUD MICROPHYSICS PARAMETERIZATION IN THE SIMULATION OF MESOSCALE CONVECTIVE SYSTEMS AND ANVIL

    E-Print Network [OSTI]

    THE ROLE OF CLOUD MICROPHYSICS PARAMETERIZATION IN THE SIMULATION OF MESOSCALE CONVECTIVE SYSTEMS in the Simulation of Mesoscale Convective Systems and Anvil Clouds in the Tropical Western Pacific K. Van Weverberg1 cloud microphysics in the simulation of mesoscale convective systems (MCSs) in the tropical western

  19. Designing Better Scaffolding in Simulation-Based Learning Environments Teaching Science Systems: A Pilot Study Report

    E-Print Network [OSTI]

    Designing Better Scaffolding in Simulation-Based Learning Environments Teaching Science Systems strong science background. They were asked to learn a chemical system in a simulation-based environment; simulation-based learning environments; scaffolding. Research Background Systems thinking skills have become

  20. Information Reuse and System Integration in the Development of a Hurricane Simulation System*

    E-Print Network [OSTI]

    Chen, Shu-Ching

    , the insurance industry was totally shaken to the tune of $15.5 billion losses caused by Hurricane Andrew [20Information Reuse and System Integration in the Development of a Hurricane Simulation System* Shu@fiu.edu * ©©©© 2003 IEEE Abstract - This paper presents our effort in designing and implementing an advanced hurricane

  1. Improving Domotic Services Combining a Dialog System and a Resident Tracking System

    E-Print Network [OSTI]

    Instituto de Sistemas e Robotica

    equip a house nowadays include: alarm systems, HVAC systems (Heating, Ventilation, and Air Conditioning, consider a lights remote control: if the resident has a wireless remote control with which he can control

  2. Lattice simulations for few- and many-body systems

    E-Print Network [OSTI]

    Dean Lee

    2008-12-13T23:59:59.000Z

    We review the recent literature on lattice simulations for few- and many-body systems. We focus on methods and results that combine the framework of effective field theory with computational lattice methods. Lattice effective field theory is discussed for cold atoms as well as low-energy nucleons with and without pions. A number of different lattice formulations and computational algorithms are considered, and an effort is made to show common themes in studies of cold atoms and low-energy nuclear physics as well as common themes in work by different collaborations.

  3. Vehicle & Systems Simulation & Testing | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your DensityEnergy U.S.-China Electric Vehicle and03/02 TUEValidation of& Systems Simulation & Testing

  4. A high-performance workflow system for subsurface simulation

    SciTech Connect (OSTI)

    Freedman, Vicky L.; Chen, Xingyuan; Finsterle, Stefan A.; Freshley, Mark D.; Gorton, Ian; Gosink, Luke J.; Keating, Elizabeth; Lansing, Carina; Moeglein, William AM; Murray, Christopher J.; Pau, George Shu Heng; Porter, Ellen A.; Purohit, Sumit; Rockhold, Mark L.; Schuchardt, Karen L.; Sivaramakrishnan, Chandrika; Vesselinov, Velimir V.; Waichler, Scott R.

    2014-02-14T23:59:59.000Z

    Subsurface modeling applications typically neglect uncertainty in the conceptual models, past or future scenarios, and attribute most or all uncertainty to errors in model parameters. In this contribution, uncertainty in technetium-99 transport in a heterogeneous, deep vadose zone is explored with respect to the conceptual model using a next generation user environment called Akuna. Akuna provides a range of tools to manage environmental modeling projects, from managing simulation data to visualizing results from high-performance computational simulators. Core toolsets accessible through the user interface include model setup, grid generation, parameter estimation, and uncertainty quantification. The BC Cribs site at Hanford in southeastern Washington State is used to demonstrate Akuna capabilities. At the BC Cribs site, conceptualization of the system is highly uncertain because only sparse information is available for the geologic conceptual model, the physical and chemical properties of the sediments, and the history of waste disposal operations. Using the Akuna toolset to perform an analysis of conservative solute transport, significant prediction uncertainty in simulated concentrations is demonstrated by conceptual model variation. This demonstrates that conceptual model uncertainty is an important consideration in sparse data environments such as BC Cribs. It is also demonstrated that Akuna and the underlying toolset provides an integrated modeling environment that streamlines model setup, parameter optimization, and uncertainty analyses for high-performance computing applications.

  5. Screening analysis for EPACT-covered commercial HVAC and water-heating equipment

    SciTech Connect (OSTI)

    S Somasundaram; PR Armstrong; DB Belzer; SC Gaines; DL Hadley; S Katipumula; DL Smith; DW Winiarski

    2000-05-25T23:59:59.000Z

    EPCA requirements state that if the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE) amends efficiency levels prescribed in Standard 90.1-1989, then DOE must establish an amended uniform national manufacturing standard at the minimum level specified in amended Standard 90.1. However, DOE can establish higher efficiency levels if it can show through clear and convincing evidence that a higher efficiency level, that is technologically feasible and economically justified, would produce significant additional energy savings. On October 29, 1999, ASHRAE approved the amended Standard 90.1, which increases the minimum efficiency levels for some of the commercial heating, cooling, and water-heating equipment covered by EPCA 92. DOE asked Pacific Northwest National Laboratory (PNNL) to conduct a screening analysis to determine the energy-savings potential of the efficiency levels listed in Standard 90.1-1999. The analysis estimates the annual national energy consumption and the potential for energy savings that would result if the EPACT-covered products were required to meet these efficiency levels. The analysis also estimates additional energy-savings potential for the EPACT-covered products if they were to exceed the efficiency levels prescribed in Standard 90-1-1999. In addition, a simple life-cycle cost (LCC) analysis was performed for some alternative efficiency levels. This paper will describe the methodology, data assumptions, and results of the analysis. The magnitude of HVAC and SWH loads imposed on equipment depends on the building's physical and operational characteristics and prevailing climatic conditions. To address this variation in energy use, coil loads for 7 representative building types at 11 climate locations were estimated based on a whole-building simulation.

  6. User Simulation in Dialogue Systems using Inverse Reinforcement Learning Senthilkumar Chandramohan 1,3

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    User Simulation in Dialogue Systems using Inverse Reinforcement Learning Senthilkumar Chandramohan based on Inverse Reinforcement Learning (IRL). The task of building the user simulator is perceived is an expensive process. User simulators aim at simulating human users in order to generate synthetic data

  7. Residential Real-time Price Response Simulation

    SciTech Connect (OSTI)

    Widergren, Steven E.; Subbarao, Krishnappa; Chassin, David P.; Fuller, Jason C.; Pratt, Robert G.

    2011-10-10T23:59:59.000Z

    The electric industry is gaining experience with innovative price responsive demand pilots and limited roll-outs to customers. One of these pilots is investigating real-time pricing signals to engage end-use systems and local distributed generation and storage in a distributed optimization process. Attractive aspects about the approach include strong scalability characteristics, simplified interfaces between automation devices, and the adaptability to integrate a wide variety of devices and systems. Experience in this nascent field is revealing a rich array of for engineering decisions and the application of complexity theory. To test the decisions, computer simulations are used to reveal insights about design, demand elasticity, and the limits of response (including consumer fatigue). Agent-based approaches lend themselves well in the simulation to modeling the participation and interaction of each piece of equipment on a distribution feeder. This paper discusses rate design and simulation experiences at the distribution feeder level where consumers and their HVAC systems and water heaters on a feeder receive real-time pricing signals.

  8. Toward Green Systems for Cleanrooms: Energy Efficient Fan-filter Units Ming-Shan Jeng, Industrial Technology Research Institute, msjeng@itri.org.tw

    E-Print Network [OSTI]

    of twenty FFUs collected from the market were tested, including thirteen 1220 mm x 610 mm (or 4 ft x 2 ft technology with architecture and natural resources. Cleanroom HVAC systems account for a large portion of energy use in cleanrooms. Improving energy efficiency of HVAC systems and their components can contribute

  9. A Simulation Tool for Real-time Systems using Environmental Energy Harvesting Maryline CHETTO

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    A Simulation Tool for Real-time Systems using Environmental Energy Harvesting Maryline CHETTO, we present a simulation tool for real-time systems using environmental energy harvesting. Energy. The simulator enables to construct an optimal schedule for any task set, battery capacity and energy source

  10. A Scalable Parallel Monte Carlo Method for Free Energy Simulations of Molecular Systems

    E-Print Network [OSTI]

    Chan, Derek Y C

    A Scalable Parallel Monte Carlo Method for Free Energy Simulations of Molecular Systems MALEK O for problems where the energy dominates the entropy. An example is parallel tempering, in which simulations the free energy of the system as a direct output of the simulation. Traditional Metropolis MC samples phase

  11. Simulative Evaluation of a UMTS-based Car-to-Infrastructure Traffic Information System

    E-Print Network [OSTI]

    Breu, Ruth

    Simulative Evaluation of a UMTS-based Car-to-Infrastructure Traffic Information System (Invited-to-Infrastructure (C2I) applications. Based on our simulation framework, we evaluated a UMTS-based Traffic Information model of the simulated UMTS-based Car-to-Infrastructure communication system 3G networks are quite

  12. Applications of Ontologies for Assembling Simulation Models of Industrial Systems

    E-Print Network [OSTI]

    -automated semantic engine that assembles the simulation model. We represent a structure of a real industrial plant in a plant ontology and available simulation blocks in a simulation ontology. Signals of each simulation critical scenarios of nuclear power plants [9]. As some real experiments cannot be repeated under the same

  13. Use of Building Automation System Trend Data for Inputs Generation in Bottom-Up Simulation Calibration

    E-Print Network [OSTI]

    Zibin, N. F.; Zmeureanu, R. G.; Love, J. A.

    2013-01-01T23:59:59.000Z

    for analysis and use in simulation is very large. This paper explores automating the process of generating inputs from Building Automation System (BAS) trend data for use in building simulation software. A proof-of-concept prototype called the Automatic...

  14. Time-domain Simulation of Multibody Floating Systems based on State-space Modeling Technology 

    E-Print Network [OSTI]

    Yu, Xiaochuan

    2012-10-19T23:59:59.000Z

    A numerical scheme to simulate time-domain motion responses of multibody floating systems has been successfully proposed. This scheme is integrated into a time-domain simulation tool, with fully coupled hydrodynamic ...

  15. Performance comparison of U.K. low-energy cooling systems by energy simulation

    E-Print Network [OSTI]

    Olsen, Erik L. (Erik Lee), 1979-

    2002-01-01T23:59:59.000Z

    Building energy simulation is an important tool for evaluating the energy consumption of a building and can provide guidance in the design of a building and its mechanical systems. EnergyPlus is a new energy simulation ...

  16. Fouling of HVAC Fin and Tube Heat Exchangers Jeffrey Siegel and Van P. Carey

    E-Print Network [OSTI]

    , particularly air conditioner evaporators, is especially important as space cooling in buildings is an important-entrained in the airflow. Before discussing the details of particle deposition on air conditioner evaporators in residential, commercial and industrial HVAC applications. Invariably, indoor and outdoor air contaminants foul

  17. Simulation of electric vehicles with hybrid power systems

    SciTech Connect (OSTI)

    Burke, A.F.; Cole, G.H.

    1990-01-01T23:59:59.000Z

    Computer programs for the simulation of the operation of electric vehicles with hybrid power systems are described. These programs treat cases in which high energy density ultracapacitors or high power density pulse batteries are used to load level the main energy storage battery in the vehicle. A generalized control strategy for splitting the power between the main battery and the pulse power devices is implemented such that the user can specify the nominal battery power as a function of the state-of-charge of the ultracapacitor or pulse power battery. The programs display graphically on the screen, as they run, the power from both the main battery and the pulse power device and the state-of-charge of the pulse power device. After each run is completed, a summary is printed out from which the effect of load leveling the battery on vehicle range and energy consumption can be determined. Default input files are provided with the programs so various combinations of vehicles, driveline components, and batteries of special current interest to the EV community can be run with either type of pulse power device. Typical simulation results are shown including cases in which the pulse power devices are connected in parallel with the main battery without interface electronics. 2 refs., 7 figs., 14 tabs.

  18. Simulated watershed responses to land cover changes using the Regional Hydro-Ecological Simulation System

    E-Print Network [OSTI]

    Tarboton, David

    Simulated watershed responses to land cover changes using the Regional Hydro-Ecological Simulation Old Main Hill, Logan, UT, 84322-8200, USA Abstract: In this work, we used the Regional Hydro

  19. Dynamic Simulation and Optimization of Nuclear Hydrogen Production Systems

    SciTech Connect (OSTI)

    Paul I. Barton; Mujid S. Kaximi; Georgios Bollas; Patricio Ramirez Munoz

    2009-07-31T23:59:59.000Z

    This project is part of a research effort to design a hydrogen plant and its interface with a nuclear reactor. This project developed a dynamic modeling, simulation and optimization environment for nuclear hydrogen production systems. A hybrid discrete/continuous model captures both the continuous dynamics of the nuclear plant, the hydrogen plant, and their interface, along with discrete events such as major upsets. This hybrid model makes us of accurate thermodynamic sub-models for the description of phase and reaction equilibria in the thermochemical reactor. Use of the detailed thermodynamic models will allow researchers to examine the process in detail and have confidence in the accurary of the property package they use.

  20. Stability limit of room air temperature of a VAV system

    SciTech Connect (OSTI)

    Matsuba, Tadahiko; Kamimura, Kazuyuki [Yamatake-Honeywell Co., Ltd., Tokyo (Japan). Building System Div.; Kasahara, Masato; Kimbara, Akiomi; Kurosu, Shigeru [Oyama National Coll. of Technology (Japan); Murasawa, Itaru; Hashimoto, Yukihiko [Tonets Corp., Tokyo (Japan). Engineering Project Dept.

    1998-12-31T23:59:59.000Z

    To control heating, ventilating, and air-conditioning (HVAC) systems, it has been necessary to accept an analog system controlled mainly by proportional-plus-integral-plus-derivative (PID) action. However, when conventional PID controllers are replaced with new digital controllers by selecting the same PID parameters as before, the control loops have often got into hunting phenomena, which result in undamped oscillations. Unstable control characteristics (such as huntings) are thought to be one of the crucial problems faced by field operators. The PID parameters must be carefully selected to avoid instabilities. In this study, a room space is simulated as a thermal system that is air-conditioned by a variable-air-volume (VAV) control system. A dynamic room model without infiltration or exfiltration, which is directly connected to a simple air-handling unit without an economizer, is developed. To explore the possible existence of huntings, a numerical system model is formulated as a bilinear system with time-delayed feedback, and a parametric analysis of the stability limit is presented. Results are given showing the stability region affected by the selection of control and system parameters. This analysis was conducted to help us tune the PID controllers for optimal HVAC control.