National Library of Energy BETA

Sample records for humidity reference system

  1. Surface Temperature Humidity Reference System Handbook - November 2005

    SciTech Connect (OSTI)

    MT Ritsche

    2005-11-30

    The Surface Temperature and Humidity Reference (SURTHREF) system is intended to provide accurate reference values of ambient temperature and relative humidity for comparison with radiosonde prelaunch values.

  2. Direct Expansion Air Conditioning System Selection for Hot & Humid Climates 

    E-Print Network [OSTI]

    Browning, B. K.

    2002-01-01

    This paper discusses some of the difficulties of selecting direct expansion (DX) air conditioning systems to dehumidify conditioned spaces in hot & humid climates. It is a common opinion among designers that concerns of humidity control are best...

  3. Precision displacement reference system

    DOE Patents [OSTI]

    Bieg, Lothar F. (Albuquerque, NM); Dubois, Robert R. (Albuquerque, NM); Strother, Jerry D. (Edgewood, NM)

    2000-02-22

    A precision displacement reference system is described, which enables real time accountability over the applied displacement feedback system to precision machine tools, positioning mechanisms, motion devices, and related operations. As independent measurements of tool location is taken by a displacement feedback system, a rotating reference disk compares feedback counts with performed motion. These measurements are compared to characterize and analyze real time mechanical and control performance during operation.

  4. Technical and Economic Analysis of Solar Cooling Systems in a Hot and Humid Climate 

    E-Print Network [OSTI]

    Moaveni, H.

    2010-01-01

    The aim of this paper is to promote efficient and cost effective implementation of advanced solar cooling systems and techniques for the hot and humid climates cities in the United States. After an introduction of basic ...

  5. SNAP operating system reference manual

    SciTech Connect (OSTI)

    Sabuda, J.D.; Polito, J.; Walker, J.L.; Grant, F.H. III

    1982-03-01

    The SNAP Operating System (SOS) is a FORTRAN 77 program which provides assistance to the safeguards analyst who uses the Safeguards Automated Facility Evaluation (SAFE) and the Safeguards Network Analysis Procedure (SNAP) techniques. Features offered by SOS are a data base system for storing a library of SNAP applications, computer graphics representation of SNAP models, a computer graphics editor to develop and modify SNAP models, a SAFE-to-SNAP interface, automatic generation of SNAP input data, and a computer graphic post-processor for SNAP. The SOS Reference Manual provides detailed application information concerning SOS as well as a detailed discussion of all SOS components and their associated command input formats. SOS was developed for the US Nuclear Regulatory Commission's Office of Nuclear Regulatory Research and the US Naval Surface Weapons Center by Pritsker and Associates, Inc., under contract to Sandia National Laboratories.

  6. Alternate Air Delivery Systems for Hot and Humid Climates 

    E-Print Network [OSTI]

    Wallace, M.

    1996-01-01

    Carter & Burgess first began using triple deck multi-zone units, in place of traditional VAV systems, on the Texas State Capitol restoration. Since the completion of that project design in early 1991, our firm has now used triple deck multi...

  7. Energy Master Plans for Sustainable, High Performance HVAC and Associated Systems for Hot and Humid Climates 

    E-Print Network [OSTI]

    Maisey, G. E.; Milestone, B.

    2004-01-01

    for SUSTAINABLE, HIGH PERFORMANCE HVAC & ASSOCIATED SYSTEMS for HOT AND HUMID CLIMATES Grahame E. Maisey, P.E. Beverly Milestone Chief Engineer President GEMCO Energy Master Planners GEMCO Energy Master Planners Div. of Building... the pieces of true sustainable design and then assemble the pieces into whole sustainable, high performance HVAC systems. These are presented to the owner as the target to reach. A detailed, in depth energy master plan is the ideal way to achieve...

  8. Measured impacts of supermarket humidity level on defrost performance and refrigerating system energy use

    SciTech Connect (OSTI)

    Henderson, H.I.; Khattar, M.

    1999-07-01

    This paper presents field-monitor data from two supermarkets where the impact of space humidity on refrigerating system energy use was evaluated. Direct digital control (DDC) systems were used at both stores to collect 15-minute monitored data. At Store A in Minneapolis, the DDC system was used to monitor system performance as well as to implement temperature-terminated control in place of time-terminated control on 16 refrigerated zones using hot gas defrost. At Store B in Indianapolis, the DDC system was used to quantify the performance trends for the single compressor rack system with electric defrost. The results at Store B showed that refrigerating system energy use decreases by nearly 10 kWh/day for each 1% drop in space relative humidity, or about 0.4% of average annual system energy use. This value includes the impact of reduced latent loads, the reduction in direct energy use and imposed load from reduced electric defrost heater operation, and the smaller imposed load from reduced anti-sweat heater energy use. The measured reductions agree well with the impact predicted using the calculation methods developed by Howell (1933b) in ASHRAE Research Project 596. At Store A, the measured data show that implementing temperature-terminated defrost reduced refrigerating system energy use by nearly 70 kWh/day over the winter period when the average space humidity was 22% RH. The savings from temperature-terminated defrost increase by 4 kWh/day per each 1% drop in relative humidity. At both stores, the same type of mechanical controls were used to duty cycle the anti-sweat heaters based on store dew point. Anti-sweat heater electricity use was observed to decrease by 4.6 kWh/day at Store B and 3.4 kWh/day at Store A for each 1% drop in relative humidity. At Store A, a more aggressive control scheme was implemented with the DDC system that reduced anti-sweat heater energy use by 7.8 kWh/day per % RH. The more aggressive control approach was reported to properly control fogging and condensation on display case surfaces. The overall energy reduction factor at the two stores was 12 kWh/day per % RH at Store A and 15 kWh/day per % RH at Store B. With more aggressive anti-sweat heater control, reduction factors as high as 20 kWh/day per % RH appear to be possible.

  9. Positional reference system for ultraprecision machining

    DOE Patents [OSTI]

    Arnold, J.B.; Burleson, R.R.; Pardue, R.M.

    1980-09-12

    A stable positional reference system for use in improving the cutting tool-to-part contour position in numerical controlled-multiaxis metal turning machines is provided. The reference system employs a plurality of interferometers referenced to orthogonally disposed metering bars which are substantially isolated from machine strain induced position errors for monitoring the part and tool positions relative to the metering bars. A microprocessor-based control system is employed in conjunction with the plurality of positions interferometers and part contour description data input to calculate error components for each axis of movement and output them to corresponding axis driven with appropriate scaling and error compensation. Real-time position control, operating in combination with the reference system, makes possible the positioning of the cutting points of a tool along a part locus with a substantially greater degree of accuracy than has been attained previously in the art by referencing and then monitoring only the tool motion relative to a reference position located on the machine base.

  10. Experimental Study in Energy Performance of Temperature and Humidity Independent Control System with Multiple Split Air-Conditioning System 

    E-Print Network [OSTI]

    Kawano,M.

    2014-01-01

    ? [k W h] E le ct ri c p o w e r co n su m p ti o n ? kW h /y e a r? 12,000 10,0 8,0 6,0 4,0 2,0 0 Outdoor air-conditioning unit Indoor unit Outdoor unit A Humidity Control unit Indoor unit Outdoor unit Outdoor air-conditioning unit A Humidity... Control unit Indoor unit Outdoor unit Developed system onventional system E le ct ri c p o w e r co n su m p ti o n ? kW h /m o n th ? 1,400 1,200 1,000 800 600 400 200 0 E le ct ri c p o w e r co n su m p ti o n ? kW h /m o n th ? 1,400 1,200 1,000 800...

  11. Temperature, Humidity, Wind and Pressure Sensors (THWAPS) Handbook

    SciTech Connect (OSTI)

    Ritsche, MT

    2011-01-17

    The temperature, humidity, wind, and pressure system (THWAPS) provide surface reference values of these measurements for balloon-borne sounding system (SONDE) launches. The THWAPS is located adjacent to the SONDE launch site at the Southern Great Plains (SGP) Central Facility. The THWAPS system is a combination of calibration-quality instruments intended to provide accurate measurements of meteorological conditions near the surface. Although the primary use of the system is to provide accurate surface reference values of temperature, pressure, relative humidity (RH), and wind velocity for comparison with radiosonde readings, the system includes a data logger to record time series of the measured variables.

  12. Organic farming practices for rice under diversified cropping systems in humid tropics.

    E-Print Network [OSTI]

    Varughese, Kuruvilla Dr; Rani, B Dr; Abraham, Suja; John, Jacob Dr; M, Vijayan Dr

    2009-01-01

    HTM (accessed on 15-1- KAU (Kerala Agricultural University).Crops. (2002) 12 th edition, Kerala Agricultural University,humid tropical regions of Kerala there is a reduction in

  13. Reference Model for Control and Automation Systems in Electrical...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Model for Control and Automation Systems in Electrical Power (October 2005) Reference Model for Control and Automation Systems in Electrical Power (October 2005) Modern...

  14. Pronominal System and Reference in Pulaar

    E-Print Network [OSTI]

    Ba, Ibrahima

    2015-12-20

    This paper examines pronominal reference and the long-distance anaphor in Pulaar, a West African language spoken from Senegal to Niger and Cameroon. I am focusing on Toore, a dialect of Pulaar spoken in southern Senegal. ...

  15. Methodology to Develop and Test an Easy-to-use Procedure for the Preliminary Selection of High-performance Systems for Office Buildings in Hot and Humid Climates 

    E-Print Network [OSTI]

    Cho, Sool Yeon

    2010-10-12

    A procedure has been developed for the preliminary selection of high-performance systems for office buildings in hot and humid climates. High-performance building systems and components were surveyed for buildings in the ...

  16. Reference Model for Control and Automation Systems in Electrical...

    Office of Environmental Management (EM)

    Reference Model for Control and Automation Systems in Electrical Power Version 1.2 October 12, 2005 Prepared by: Sandia National Laboratories' Center for SCADA Security Jason...

  17. Integrated Hygrothermal Performance of Building Envelopes and Systems in Hot and Humid Climates 

    E-Print Network [OSTI]

    Karagiozis, A. N.; Desjarlais, A.; Salonvaara, M.

    2000-01-01

    Building Technology, Oak Ridge National Laboratory, Oak Ridge National Laboratory, Espoo, Finland Building Technology Center, Oak Ridge, Tennessee, US Oak Ridge, Tennessee, US ABSTRACT In hot and humid climates the interior and exterior environmental..., Proceedings of the 4th Symposium, Building Physics in the Nordic Countries, Espoo, Finland, Sept. 9-10, pp.447-454. Karagiozis, A. and Hadjisophocleous G. "Wind- Driven Rain on High-Rise Buildings", Thermal Performance of Exterior Envelopes of Buildings...

  18. AC System Equipment Specification, Installation and Operational Options for Improved Indoor Humidity Control 

    E-Print Network [OSTI]

    Shirey, D. B.

    2008-01-01

    Specification, Installation and Operational Options for Improved Indoor Humidity Control Don B. Shirey, III Program Manager Florida Solar Energy Center Cocoa, Florida ABSTRACT High-efficiency home designs have significantly reduced sensible...: Florida Solar Energy Center. James, P., J.E. Cummings, J. Sonne, R. Vieira, J. Klongerbo. 1997. The Effect of Residential Equipment Capacity on Energy Use, Demand, and Run-Time, FSEC-PF-328-97. Cocoa, FL: Florida Solar Energy Center. Lennox...

  19. Data Center Economizer Contamination and Humidity Study

    E-Print Network [OSTI]

    Shehabi, Arman

    2010-01-01

    Data Center Economizer Contamination and Humidity Studyoccupants. To investigate contamination levels, particlemethod of collecting contamination readings. The system,

  20. Apparatus for adjusting and maintaining the humidity of gas at a constant value within a closed system

    DOE Patents [OSTI]

    Abernathy, B.R.; Walters, R.R.

    1985-08-05

    The humidity of a gas within a closed system is maintained at constant level by providing a saturated salt solution within a lower chamber in communication with an upper chamber conjointly defined by upper and lower container sections in sealing contact with each other to establish a closed container. A partition wall separates the salt solution from the test region in the upper chamber. A tube extending through the partition plate allows humidified gas to pass from the lower to the upper chamber. A glass wool plug or membranous material within the tube prevents migration of salt into the test region.

  1. Apparatus for adjusting and maintaining the humidity of gas at a constant value within a closed system

    DOE Patents [OSTI]

    Abernathy, Bethel R. (Franklin, OH); Walters, Ronald R. (Germantown, OH)

    1986-01-01

    The humidity of a gas within a closed system is maintained at constant level by providing a saturated salt solution within a lower chamber in communication with an upper chamber conjointly defined by upper and lower container sections in sealing contact with each other to establish a closed container. A partition wall separates the salt solution from the test region in the upper chamber. A tube extending through the partition plate allows humidified gas to pass from the lower to the upper chamber. A glass wool plug or membranous material within the tube prevents migration of salt into the test region.

  2. PARAMETRIC STUDY OF GROUND SOURCE HEAT PUMP SYSTEM FOR HOT AND HUMID CLMATE

    SciTech Connect (OSTI)

    Jiang Zhu; Yong X. Tao

    2011-11-01

    The U-tube sizes and varied thermal conductivity with different grout materials are studied based on the benchmark residential building in Hot-humid Pensacola, Florida. In this study, the benchmark building is metered and the data is used to validate the simulation model. And a list of comparative simulation cases with varied parameter value are simulated to study the importance of pipe size and grout to the ground source heat pump energy consumption. The simulation software TRNSYS [1] is employed to fulfill this task. The results show the preliminary energy saving based on varied parameters. Future work needs to be conducted for the cost analysis, include the installation cost from contractor and materials cost.

  3. Indoor Humidity Analysis of an Integrated Radiant Cooling and Desiccant Ventilation System 

    E-Print Network [OSTI]

    Gong, X.; Claridge, D. E.

    2006-01-01

    latent heat, they normally are used in conjunction with an independent ventilation system, which is capable of decoupling the space sensible and latent loads. Condensation concerns limit the application of radiant cooling. This paper studies...

  4. Humidity Control Systems for Civil Buildings in Hot Summer and Cold Winter Zone in China 

    E-Print Network [OSTI]

    Yu, X.

    2006-01-01

    ) systems. Based on our research, this paper further provides the rate and characteristics of moisture resources in civil buildings. Although the ventilation rate is limited with the minimum ventilation rate in the sanitation ventilation mode of the air...

  5. Learning user modelling strategies for adaptive referring expression generation in spoken dialogue systems 

    E-Print Network [OSTI]

    Janarthanam, Srinivasan Chandrasekaran

    2011-06-30

    We address the problem of dynamic user modelling for referring expression generation in spoken dialogue systems, i.e how a spoken dialogue system should choose referring expressions to refer to domain entities to users ...

  6. Effects of Radiant Barrier Systems on Ventilated Attics in a Hot and Humid Climate 

    E-Print Network [OSTI]

    Medina, M. A.; O'Neal, D. L.; Turner, W. D.

    1992-01-01

    was not sensitive to increased airflows. The ceiling heat flux reductions produced by the radiant barrier systems were between 25 and 34 percent, with 28 percent being the reduction observed most often in the presence of attic ventilation. All results presented...

  7. Mechanical Air Distribution Interactions with the House System in Hot and Humid Climates 

    E-Print Network [OSTI]

    Garrett, D. A.

    1994-01-01

    as it is with the air conditioner. When a heat pump can no longer meet the demand it falls back on strip heat resulting in a very large loss in system operating efficiency, not just longer run times. Return leaks can also draw in gases like radon as we... LIABILITY Consider for a moment the liability associated with designing or building a home in which interac- tions between the home and the equipment are found to introduce carbon monoxide, large quantities of moisture, radon. allergens, or particulates...

  8. Reference reactor module for NASA's lunar surface fission power system

    SciTech Connect (OSTI)

    Poston, David I; Kapernick, Richard J; Dixon, David D; Werner, James; Qualls, Louis; Radel, Ross

    2009-01-01

    Surface fission power systems on the Moon and Mars may provide the first US application of fission reactor technology in space since 1965. The Affordable Fission Surface Power System (AFSPS) study was completed by NASA/DOE to determine the cost of a modest performance, low-technical risk surface power system. The AFSPS concept is now being further developed within the Fission Surface Power (FSP) Project, which is a near-term technology program to demonstrate system-level TRL-6 by 2013. This paper describes the reference FSP reactor module concept, which is designed to provide a net power of 40 kWe for 8 years on the lunar surface; note, the system has been designed with technologies that are fully compatible with a Martian surface application. The reactor concept uses stainless-steel based. UO{sub 2}-fueled, pumped-NaK fission reactor coupled to free-piston Stirling converters. The reactor shielding approach utilizes both in-situ and launched shielding to keep the dose to astronauts much lower than the natural background radiation on the lunar surface. The ultimate goal of this work is to provide a 'workhorse' power system that NASA can utilize in near-term and future Lunar and Martian mission architectures, with the eventual capability to evolve to very high power, low mass systems, for either surface, deep space, and/or orbital missions.

  9. Consistent methodology for technology and policy impact assessment. [Reference energy system

    SciTech Connect (OSTI)

    Beller, M

    1980-10-01

    A Reference Energy System is a useful tool for providing a baseline for energy technology and policy analysis. The technique of developing a Reference Energy System is described, and its use in various analyses is outlined.

  10. A New Ventilation System Integrates Total Energy Recovery, Conventional Cooling and a Novel 'Passive' Dehumidification Wheel to Mitigate the Energy, Humidity Control and First Cost Concerns Often Raised when Designing for ASHRAE Standard 62-1999 Compliance 

    E-Print Network [OSTI]

    Fischer, J. C.

    2000-01-01

    to very low dewpoints unattainable with conventional cooling approaches. The system allows for precise control of the indoor space humidity while delivering high quantities of outdoor air, at both peak and part load conditions, and during both occupied...

  11. Analysis of the Energy Savings Potential in K-5 Schools in Hot and Humid Climates: Application of High Performance Measures and Renewable Energy Systems 

    E-Print Network [OSTI]

    Im, P.; Haberl, J.

    2010-01-01

    OF THE ENERGY SAVINGS POTENTIAL IN K-5 SCHOOLS IN HOT AND HUMID CLIMATES: APPLICATION OF HIGH PERFORMANCE MEASURES AND RENEWABLE ENERGY SYSTEMS1 Piljae Im1, and Jeff S. Haberl2 1Oak Ridge National Laboratory, Oak Ridge, TN 2Texas A&M University... recommended as in the ASHRAE Advanced Energy Design Guides for K-12 Schools. As an effort to investigate more energy savings potential for the school building, several other energy savings measures and renewable energy measures were applied to the target...

  12. Optical humidity sensor

    DOE Patents [OSTI]

    Tarvin, Jeffrey A. (Ann Arbor, MI)

    1987-01-01

    An optical dielectric humidity sensor which includes a dielectric mirror having multiple alternating layers of two porous water-adsorbent dielectric materials with differing indices of refraction carried by a translucent substrate. A narrow-band polarized light source is positioned to direct light energy onto the mirror, and detectors are positioned to receive light energy transmitted through and reflected by the mirror. A ratiometer indicates humidity in the atmosphere which surrounds the dielectric mirror as a function of a ratio of light energies incident on the detectors.

  13. Optical humidity sensor

    DOE Patents [OSTI]

    Tarvin, J.A.

    1987-02-10

    An optical dielectric humidity sensor is disclosed which includes a dielectric mirror having multiple alternating layers of two porous water-adsorbent dielectric materials with differing indices of refraction carried by a translucent substrate. A narrow-band polarized light source is positioned to direct light energy onto the mirror, and detectors are positioned to receive light energy transmitted through and reflected by the mirror. A ratiometer indicates humidity in the atmosphere which surrounds the dielectric mirror as a function of a ratio of light energies incident on the detectors. 2 figs.

  14. Building America Residential System Research Results: Achieving 30% Whole House Energy Savings Level in Mixed-Humid Climates; January 2006 - December 2006

    SciTech Connect (OSTI)

    Building America Industrialized Housing Partnership; Building Industry Research Alliance; Building Science Consortium; Consortium for Advanced Residential Buildings; Davis Energy Group; IBACOS; National Association of Home Builders Research Center; National Renewable Energy Laboratory

    2006-12-01

    The Building America program conducts the system research required to reduce risks associated with the design and construction of homes that use an average of 30% to 90% less total energy for all residential energy uses than the Building America Research Benchmark, including research on homes that will use zero net energy on annual basis. To measure the program's progress, annual research milestones have been established for five major climate regions in the United States. The system research activities required to reach each milestone take from 3 to 5 years to complete and include research in individual test houses, studies in pre-production prototypes, and research studies with lead builders that provide early examples that the specified energy savings level can be successfully achieved on a production basis. This report summarizes research results for the 30% energy savings level and demonstrates that lead builders can successfully provide 30% homes in the Mixed-Humid Climate Region on a cost-neutral basis.

  15. Control of Vibration in Mechanical Systems Using Shaped Reference Inputs

    E-Print Network [OSTI]

    Meckl, Peter Heinrich

    1988-01-01

    Dynamic systems which undergo rapid motion can excite natural frequencies that lead to residual vibration at the end of motion. This work presents a method to shape force profiles that reduce excitation energy at the ...

  16. Evaluation of Humidity Control Options in Hot-Humid Climate Homes (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2011-12-01

    This technical highlight describes NREL research to analyze the indoor relative humidity in three home types in the hot-humid climate zone, and examine the impacts of various dehumidification equipment and controls. As the Building America program researches construction of homes that achieve greater source energy savings over typical mid-1990s construction, proper modeling of whole-house latent loads and operation of humidity control equipment has become a high priority. Long-term high relative humidity can cause health and durability problems in homes, particularly in a hot-humid climate. In this study, researchers at the National Renewable Energy Laboratory (NREL) used the latest EnergyPlus tool equipped with the moisture capacitance model to analyze the indoor relative humidity in three home types: a Building America high-performance home; a mid-1990s reference home; and a 2006 International Energy Conservation Code (IECC)-compliant home in hot-humid climate zones. They examined the impacts of various dehumidification equipment and controls on the high-performance home where the dehumidification equipment energy use can become a much larger portion of whole-house energy consumption. The research included a number of simulated cases: thermostat reset, A/C with energy recovery ventilator, heat exchanger assisted A/C, A/C with condenser reheat, A/C with desiccant wheel dehumidifier, A/C with DX dehumidifier, A/C with energy recovery ventilator, and DX dehumidifier. Space relative humidity, thermal comfort, and whole-house source energy consumption were compared for indoor relative humidity set points of 50%, 55%, and 60%. The study revealed why similar trends of high humidity were observed in all three homes regardless of energy efficiency, and why humidity problems are not necessarily unique in the high-performance home. Thermal comfort analysis indicated that occupants are unlikely to notice indoor humidity problems. The study confirmed that supplemental dehumidification is needed to maintain space relative humidity (RH) below 60% in a hot-humid climate home. Researchers also concluded that while all the active dehumidification options included in the study successfully controlled space relative humidity excursions, the increase in whole-house energy consumption was much more sensitive to the humidity set point than the chosen technology option. In the high-performance home, supplemental dehumidification equipment results in a significant source energy consumption penalty at 50% RH set point (12.6%-22.4%) compared to the consumption at 60% RH set point (1.5%-2.7%). At 50% and 55% RH set points, A/C with desiccant wheel dehumidifier and A/C with ERV and high-efficiency DX dehumidifier stand out as the two cases resulting in the smallest increase of source energy consumption. At an RH set point of 60%, all explicit dehumidification technologies result in similar insignificant increases in source energy consumption and thus are equally competitive.

  17. Water Rights Analysis Package (WRAP) Modeling System Reference Manual 

    E-Print Network [OSTI]

    Wurbs, R.

    2012-10-01

    Inflows and Outflows ............................................................................................... 96 Hydroelectric Energy Generation ....................................................................................... 96 Instream... contributed to development and improvement of the model. The original WRAP, initially called TAMUWRAP, stemmed from a 1986-1988 research project at Texas A&M University, entitled Optimizing Reservoir System Operations, which was sponsored by a federal...

  18. REFERENCE: The Blue Planet An Introduction to Earth System

    E-Print Network [OSTI]

    Gilbes, Fernando

    on measurements of the expansion, measurements of temperature fluctuations in the cosmic microwave background years. (Hinshaw, G., et al. (2008). "Five-Year Wilkinson Microwave Anisotropy Probe (WMAP) Observations. Scientists hypothesize that the solar system formed from a huge, rotating cloud of cosmic gas (Nebular

  19. Analysis of Innovative HVAC System Technologies and Their Application for Office Buildings in Hot and Humid Climates 

    E-Print Network [OSTI]

    Tanskyi, Oleksandr

    2012-02-14

    parameters for the Wisenbaker Engineering Research Center HVAC system simulation model.................................................................. 66 Table 3.8. DOE-2.1E system hourly reports variables... used in commercial buildings design are not adequate to save energy in both depth (savings per square foot) and scale (square footage improved each year) (RMI 2010). There are several ways to decrease energy consumption and CO2 emission caused...

  20. Energy and economic assessment of desiccant cooling systems coupled with single glazed air and hybrid PV/thermal solar collectors for applications in hot and humid climate

    SciTech Connect (OSTI)

    Beccali, Marco; Finocchiaro, Pietro; Nocke, Bettina

    2009-10-15

    This paper presents a detailed analysis of the energy and economic performance of desiccant cooling systems (DEC) equipped with both single glazed standard air and hybrid photovoltaic/thermal (PV/t) collectors for applications in hot and humid climates. The use of 'solar cogeneration' by means of PV/t hybrid collectors enables the simultaneous production of electricity and heat, which can be directly used by desiccant air handling units, thereby making it possible to achieve very energy savings. The present work shows the results of detailed simulations conducted for a set of desiccant cooling systems operating without any heat storage. System performance was investigated through hourly simulations for different systems and load combinations. Three configurations of DEC systems were considered: standard DEC, DEC with an integrated heat pump and DEC with an enthalpy wheel. Two kinds of building occupations were considered: office and lecture room. Moreover, three configurations of solar-assisted air handling units (AHU) equipped with desiccant wheels were considered and compared with standard AHUs, focusing on achievable primary energy savings. The relationship between the solar collector's area and the specific primary energy consumption for different system configurations and building occupation patterns is described. For both occupation patterns, sensitivity analysis on system performance was performed for different solar collector areas. Also, this work presents an economic assessment of the systems. The cost of conserved energy and the payback time were calculated, with and without public incentives for solar cooling systems. It is worth noting that the use of photovoltaics, and thus the exploitation of related available incentives in many European countries, could positively influence the spread of solar air cooling technologies (SAC). An outcome of this work is that SAC systems equipped with PV/t collectors are shown to have better performance in terms of primary energy saving than conventional systems fed by vapour compression chillers and coupled with PV cells. All SAC systems present good figures for primary energy consumption. The best performances are seen in systems with integrated heat pumps and small solar collector areas. The economics of these SAC systems at current equipment costs and energy prices are acceptable. They become more interesting in the case of public incentives of up to 30% of the investment cost (Simple Payback Time from 5 to 10 years) and doubled energy prices. (author)

  1. FAQS Reference Guide - Mechanical Systems | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum12, 2015Executive Order 13514ConstructionWeapon QualityFireMechanical Systems

  2. Building America Residential System Research Results: Achieving 30% Whole House Energy Savings Level in Mixed-Humid Climates; January 2006 - December 2006

    SciTech Connect (OSTI)

    Anderson, R.; Hendron, R.; Eastment, M.; Jalalzadeh-Azar, A.

    2006-12-01

    This report summarizes research results for the 30% energy savings level and demonstrates that lead builders can successfully provide 30% homes in the Mixed-Humid Climate Region on a cost-neutral basis.

  3. Carbon and Nitrogen Cycling in a Tree - Grass Inter-Cropping System in the Humid Tropics of Mexico. 

    E-Print Network [OSTI]

    Hernandez-Daumas, Salvador

    in Oaxaca, Mexico, where increases in productivity are limited by shortage of capital and where the tree component would be used as green manure. It is difficult to investigate the effectiveness of such a system by only using conventional field trials. I...

  4. The IAU Resolutions on Astronomical Reference Systems, Time Scales, and Earth Rotation Models

    E-Print Network [OSTI]

    George H. Kaplan

    2006-02-03

    Recent resolutions passed by the International Astronomical Union (IAU) on astronomical reference systems, time scales, and Earth rotation models are the most significant set of international agreements in positional astronomy in several decades. These resolutions, the result of over ten years of international research and study, provide a coherent set of foundational standards for the treatment of astrometric data and the modeling of dynamics in the solar system. This circular explains these resolutions and provides a complete set of practical formulas for their implementation. The six main chapters cover relativity, time scales, the fundamental celestial reference system, ephemerides of solar system bodies, precession and nutation, and modeling the Earth's rotation.

  5. Novel Approaches to Immobilized Heteropoly Acid Systems for High Temperature, Low Relative Humidity Polymer-Type Membranes - Final Report

    SciTech Connect (OSTI)

    Herring, Andrew M; Horan, James L; Aieta, Niccolo V; Sachdeva, Sonny; Kuo, Mei-Chen; Ren, Hui; Lingutla, Anitha; Emery, Michael; Haugen, Gregory M; Yandrasits, Michael A; Sharma, Neeraj; Coggio, William D; Hamrock, Steven J; Frey, Matthew H

    2012-05-20

    Original research was carried out at the CSM and the 3M Company from March 2007 through September 2011. The research was aimed at developing new to the world proton electrolyte materials for use in hydrogen fuel cells, in particular with high proton conductivity under hot and dry conditions (>100mS/cm at 120°C and 50%RH). Broadly stated, the research at 3M and between 3M and CSM that led to new materials took place in two phases: In the first phase, hydrocarbon membranes that could be formed by photopolymerization of monomer mixtures were developed for the purpose of determining the technical feasibility of achieving the program's Go/No-Go decision conductivity target of >100mS/cm at 120°C and 50%RH. In the second phase, attempts were made to extend the achieved conductivity level to fluorinated material systems with the expectation that durability and stability would be improved (over the hydrocarbon material). Highlights included: Multiple lots of an HPA-immobilized photocurable terpolymer derived from di-vinyl-silicotungstic acid (85%), n-butyl acrylate, and hexanediol diacrylate were prepared at 3M and characterized at 3M to exhibit an initial conductivity of 107mS/cm at 120°C and 47%RH (PolyPOM85v) using a Bekktech LLC sample fixture and TestEquity oven. Later independent testing by Bekktech LLC, using a different preheating protocol, on the same material, yielded a conductivity value of approximately 20mS/cm at 120°C and 50%RH. The difference in measured values is likely to have been the result of an instability of properties for the material or a difference in the measurement method. A dispersed catalyst fuel cell was fabricated and tested using a 150¼m thick HPA-based photocurable membrane (above, PolyPOM75v), exhibiting a current density of greater than 300mA/cm2 at 0.5V (H2/Air 800/1800sccm 70°C/75%RH ambient outlet pressure). Multiple lots of a co-polymer based on poly-trifluorovinylether (TFVE) derived HPA were synthesized and fabricated into films, Generation II films. These materials showed proton conductivities as high as 1 S/cm under high RH conditions. However, the materials suffered from compromised properties due to impure monomers and low molecular weights. Multiple lots of an HPA-immobilized fluoropolymer derived from preformed PVDF-HFP (Generation III films) were synthesized and formed into membranes at 3M and characterized at 3M to exhibit conductivity reaching approximately 75mS/cm at 120°C/40%RH using a Bekktech sample fixture and TestEquity oven (optimized membrane, at close of program). Initial fuel cell fabrication and testing for this new class of membrane yielded negative results (no measureable proton conductivity); however, the specific early membrane that was used for the two 5cm2 MEAs was later determined to have <1 mS/cm at 80°C/80%RH using the Bekktech fixture, vs. ca. 200 mS/cm at 80°C/80%RH for samples of the later-optimized type described above. Future work in this area (beyond the presently reported contract) should include additional attempts to fabricate and test fuel cells based on the later-optimized Generation II and III polymer. A manufacturing study was performed which predicted no difficulties in any future scale up of the materials.

  6. Hanford Environmental Information System (HEIS). Volume 3, Subject Area reference manual

    SciTech Connect (OSTI)

    Schreck, R.I.

    1994-01-14

    The Hanford Environmental Information System (HEIS) Subject Area manuals are designed as reference guides, that is, each chapter provides the information needed to make best use of each subject area, its tables, and reporting capabilities. Each subject area is documented in a chapter in one of the subject area manuals. Because these are reference manuals, most of the information is also available in the online help system as well. See Section 5.4.2 of the HEIS User`s Guide (DOE-RL 1994a) for a detailed description of the online help.

  7. Measure Guideline: Supplemental Dehumidification in Warm-Humid Climates

    SciTech Connect (OSTI)

    Rudd, A.

    2014-10-01

    This document covers a description of the need and applied solutions for supplemental dehumidification in warm-humid climates, especially for energy efficient homes where the sensible cooling load has been dramatically reduced. In older homes in warm-humid climates, cooling loads are typically high and cooling equipment runs a lot to cool the air. The cooling process also removes indoor moisture, reducing indoor relative humidity. However, at current residential code levels, and especially for above-code programs, sensible cooling loads have been so dramatically reduced that the cooling system does not run a lot to cool the air, resulting in much less moisture being removed. In these new homes, cooling equipment is off for much longer periods of time especially during spring/fall seasons, summer shoulder months, rainy periods, some summer nights, and some winter days. In warm-humid climates, those long off periods allow indoor humidity to become elevated due to internally generated moisture and ventilation air change. Elevated indoor relative humidity impacts comfort, indoor air quality, and building material durability. Industry is responding with supplemental dehumidification options, but that effort is really in its infancy regarding year-round humidity control in low-energy homes. Available supplemental humidity control options are discussed. Some options are less expensive but may not control indoor humidity as well as more expensive and comprehensive options. The best performing option is one that avoids overcooling and avoids adding unnecessary heat to the space by using waste heat from the cooling system to reheat the cooled and dehumidified air to room-neutral temperature.

  8. Measure Guideline: Supplemental Dehumidification in Warm-Humid Climates

    SciTech Connect (OSTI)

    Rudd, Armin

    2014-10-01

    This document covers a description of the need and applied solutions for supplemental dehumidification in warm-humid climates, especially for energy efficient homes where the sensible cooling load has been dramatically reduced. Cooling loads are typically high and cooling equipment runs a lot to cool the air in older homes in warm-humid climates. The cooling process also removes indoor moisture, reducing indoor relative humidity. However, at current residential code levels, and especially for above-code programs, sensible cooling loads have been so dramatically reduced that the cooling system does not run a lot to cool the air, resulting in much less moisture being removed. In these new homes, cooling equipment is off for much longer periods of time especially during spring/fall seasons, summer shoulder months, rainy periods, some summer nights, and winter days. In warm-humid climates, those long-off periods allow indoor humidity to become elevated due to internally generated moisture and ventilation air change. Elevated indoor relative humidity impacts comfort, indoor air quality, and building material durability. Industry is responding with supplemental dehumidification options, but that effort is really in its infancy regarding year-round humidity control in low-energy homes. Available supplemental humidity control options are discussed. Some options are less expensive but may not control indoor humidity as well as more expensive and comprehensive options. The best performing option is one that avoids overcooling and adding unnecessary heat to the space by using waste heat from the cooling system to reheat the cooled and dehumidified air to room-neutral temperature.

  9. Enhancing Performance Contracts: Integrating IAQ Solutions in Hot & Humid Climates 

    E-Print Network [OSTI]

    Turner, S. C.

    1998-01-01

    in hot and humid climates, and have limited applicability along the Gulf Coast. Humidity control problems are abundant, since cool air at dawn or dusk may be near saturated, and sensible loads may be so low that system sensible heat ratio.... Recovery and outdoor air intake ducts must be close enough to make installation practical. Large air flows require large wheels, and wheel geometry dictates limited equipment configurations. Aggressive maintenance is required to sustain performance...

  10. Humidity Control in Residences 

    E-Print Network [OSTI]

    Trowbridge, J.; Peterson, J.

    1994-01-01

    should result in lower energy consumption and peak electric demand during that period. The performance of this new air conditioning system is demonstrated using FSEC 3.0, a building energy simulation program developed by the Florida Solar Energy Center...

  11. Reference concepts for a space-based hydrogen-oxygen combustion, turboalternator, burst power system

    SciTech Connect (OSTI)

    Edenburn, M.W.

    1990-07-01

    This report describes reference concepts for a hydrogen-oxygen combustion, turboalternator power system that supplies power during battle engagement to a space-based, ballistic missile defense platform. All of the concepts are open''; that is, they exhaust hydrogen or a mixture of hydrogen and water vapor into space. We considered the situation where hydrogen is presumed to be free to the power system because it is also needed to cool the platform's weapon and the situation where hydrogen is not free and its mass must be added to that of the power system. We also considered the situation where water vapor is an acceptable exhaust and the situation where it is not. The combination of these two sets of situations required four different power generation systems, and this report describes each, suggests parameter values, and estimates masses for each of the four. These reference concepts are expected to serve as a baseline'' to which other types of power systems can be compared, and they are expected to help guide technology development efforts in that they suggest parameter value ranges that will lead to optimum system designs. 7 refs., 18 figs., 5 tabs.

  12. Model-reference adaptive control applied to load-following of a space-nuclear power system

    SciTech Connect (OSTI)

    Metzger, J.D.; El-Genk, M.S.; Parlos, A.G.; New Mexico Univ., Albuquerque, NM . Inst. for Space Nuclear Power Studies; Texas A and M Univ., College Station, TX . Dept. of Nuclear Engineering)

    1989-01-01

    Nuclear power systems are presently being investigated as an alternative for both commercial and military space power systems because of their projected longevity of 7 to 10 years, their mass advantage over other space power sources at powers above approximately 25 kW{sub e}, and their ability to operate without direct illumination from the sun. These space-nuclear power systems are being designed to supply from tens of kilowatts to multimegawatts of power for continuous operation of seven years and more. Space-nuclear power systems designs that meet these requirements will not be available for refueling or maintenance during their lifetime. To ensure that the space-nuclear power system will operate safely and will respond in a predictable and desired manner, the design of the system's controller must account for changes in the system parameters over its lifetime. This paper applies model-reference adaptive control to an increase in the power demand by the load. A model-reference adaptive controller will force the actual space-nuclear power system to follow the predictable and desired response of a reference model, despite changes in the actual system's operating parameters. Included in this paper are the model-reference adaptive control algorithm, the description of the computer simulation of a space-nuclear power system and the reference model, and results that demonstrate the application of model-reference adaptive control to a change in the load power demand. The results demonstrate that model-reference adaptive control can ensure the transient response of the system despite differences between the design of the system and the as-built system as well as for variations in the systems parameters. 5 refs., 3 figs.

  13. Operators Manual and Technical Reference for the Z-Beamlet Phase Modulation Failsafe System: Version 1.

    SciTech Connect (OSTI)

    Armstrong, Darrell J.

    2014-09-01

    The need for pulse energies exceeding 4 kJ and pulse lengths [?] 2 ns in Sandia's Z-Beamlet laser (ZBL) requires that the single-frequency spectrum of its fiber-laser master oscillator be converted to a phase modulated spectrum with a modulation in dex [?] 5. Because accidental injection of single-frequency light into ZBL could result i n damage to optical materials from transverse stimulated Brillouin scattering, the presence of phase modulated (PM) light must be monitored by a reliable failsafe system that can stop a las er shot within of a few 10's of ns following a failure of the PM system. This requirement is met by combining optical heterodyne detection with high-speed electronics to indicate the pres ence or absence of phase modulated light. The transition time for the failsafe signal resultin g from a sudden failure using this technique is approximately 35 ns. This is sufficiently short to safely stop a single-frequency laser pulse from leaving ZBL's regenerative amplifier with a n approximately 35 ns margin of safety. This manual and technical reference contains detai led instructions for daily use of the PM failsafe system and provides enough additional informat ion for its maintenance and repair.

  14. The Poisson alignment reference system implementation at the Advanced Photon Source.

    SciTech Connect (OSTI)

    Feier, I.

    1998-09-21

    The Poisson spot was established using a collimated laser beam from a 3-mW diode laser. It was monitored on a quadrant detector and found to be very sensitive to vibration and air disturbances. Therefore, for future work we strongly recommend a sealed vacuum tube in which the Poisson line may be propagated. A digital single-axis feedback system was employed to generate an straight line reference (SLR) on the X axis. Pointing accuracy was better than 8 {+-} 2 microns at a distance of 5 m. The digital system was found to be quite slow with a maximum bandwidth of 47 {+-} 9 Hz. Slow drifts were easily corrected but any vibration over 5 Hz was not. We recommend an analog proportional-integral-derivative (PID) controller for high bandwidth and smooth operation of the kinematic mirror. Although the Poisson alignment system (PAS) at the Advanced Photon Source is still in its infancy, it already shows great promise as a possible alignment system for the low-energy undulator test line (LEUTL). Since components such as wigglers and quadruples will initially be aligned with respect to each other using conventional means and mounted on some kind of rigid rail, the goal would be to align six to ten such rails over a distance of about 30 m. The PAS could be used to align these rails by mounting a sphere at the joint between two rails. These spheres would need to be in a vacuum pipe to eliminate the refractive effects of air. Each sphere would not be attached to either rail but instead to a flange connecting the vacuum pipes of each rail. Thus the whole line would be made up of straight, rigid segments that could be aligned by moving the joints. Each sphere would have its own detector, allowing the operators to actively monitor the position of each joint and therefore the overall alignment of the system.

  15. Group 3: Humidity, Temperature, and Voltage (Presentation)

    SciTech Connect (OSTI)

    Wohlgemuth, J.

    2013-05-01

    Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

  16. Data Center Economizer Contamination and Humidity Study

    E-Print Network [OSTI]

    Shehabi, Arman

    2010-01-01

    Program Data Center Economizer Contamination and Humiditylevels for computers. Air economizer cycles, which bring insites to determine how economizers affect humidity control.

  17. Development of a Humid Climate Definition 

    E-Print Network [OSTI]

    Hedrick, R. L.; Shirey, D. B.

    1998-01-01

    are the number of hours per year with space humidity above 60% RH and the number of occupied hours with space humidity above 60% RH. TMY2 weather data (NREL 1995) for 10 cities was used for the annual building energy simulations. TMY2 data was also used...

  18. Data Center Economizer Contamination and Humidity Study

    E-Print Network [OSTI]

    LBNL-2424E Data Center Economizer Contamination and Humidity Study A. Shehabi, W. Tschudi, A Emerging Technologies Program Data Center Economizer Contamination and Humidity Study Lawrence Berkeley 42 #12;Executive Summary Data centers require continuous air conditioning to address high internal

  19. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Code Reference Manual

    SciTech Connect (OSTI)

    C. L. Smith; K. J. Kvarfordt; S. T. Wood

    2008-08-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment (PRA) using a personal computer. SAPHIRE is funded by the U.S. Nuclear Regulatory Commission (NRC) and developed by the Idaho National Laboratory (INL). The INL's primary role in this project is that of software developer. However, the INL also plays an important role in technology transfer by interfacing and supporting SAPHIRE users comprised of a wide range of PRA practitioners from the NRC, national laboratories, the private sector, and foreign countries. SAPHIRE can be used to model a complex system’s response to initiating events, quantify associated damage outcome frequencies, and identify important contributors to this damage (Level 1 PRA) and to analyze containment performance during a severe accident and quantify radioactive releases (Level 2 PRA). It can be used for a PRA evaluating a variety of operating conditions, for example, for a nuclear reactor at full power, low power, or at shutdown conditions. Furthermore, SAPHIRE can be used to analyze both internal and external initiating events and has special features for transforming models built for internal event analysis to models for external event analysis. It can also be used in a limited manner to quantify risk in terms of release consequences to both the public and the environment (Level 3 PRA). SAPHIRE includes a separate module called the Graphical Evaluation Module (GEM). GEM provides a highly specialized user interface with SAPHIRE that automates SAPHIRE process steps for evaluating operational events at commercial nuclear power plants. Using GEM, an analyst can estimate the risk associated with operational events in a very efficient and expeditious manner. This reference guide will introduce the SAPHIRE Version 7.0 software. A brief discussion of the purpose and history of the software is included along with general information such as installation instructions, starting and stopping the program, and some pointers on how to get around inside the program. Next, database concepts and structure are discussed. Following that discussion are nine sections, one for each of the menu options on the SAPHIRE main menu, wherein the purpose and general capabilities for each option are furnished. Next, the capabilities and limitations of the software are provided.

  20. Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) Code Reference Manual

    SciTech Connect (OSTI)

    C. L. Smith; K. J. Kvarfordt; S. T. Wood

    2006-07-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) is a software application developed for performing a complete probabilistic risk assessment (PRA) using a personal computer. SAPHIRE is funded by the U.S. Nuclear Regulatory Commission (NRC) and developed by the Idaho National Laboratory (INL). The INL's primary role in this project is that of software developer. However, the INL also plays an important role in technology transfer by interfacing and supporting SAPHIRE users comprised of a wide range of PRA practitioners from the NRC, national laboratories, the private sector, and foreign countries. SAPHIRE can be used to model a complex system’s response to initiating events, quantify associated damage outcome frequencies, and identify important contributors to this damage (Level 1 PRA) and to analyze containment performance during a severe accident and quantify radioactive releases (Level 2 PRA). It can be used for a PRA evaluating a variety of operating conditions, for example, for a nuclear reactor at full power, low power, or at shutdown conditions. Furthermore, SAPHIRE can be used to analyze both internal and external initiating events and has special features for ansforming models built for internal event analysis to models for external event analysis. It can also be used in a limited manner to quantify risk in terms of release consequences to both the public and the environment (Level 3 PRA). SAPHIRE includes a separate module called the Graphical Evaluation Module (GEM). GEM provides a highly specialized user interface with SAPHIRE that automates SAPHIRE process steps for evaluating operational events at commercial nuclear power plants. Using GEM, an analyst can estimate the risk associated with operational events in a very efficient and expeditious manner. This reference guide will introduce the SAPHIRE Version 7.0 software. A brief discussion of the purpose and history of the software is included along with general information such as installation instructions, starting and stopping the program, and some pointers on how to get around inside the program. Next, database concepts and structure are discussed. Following that discussion are nine sections, one for each of the menu options on the SAPHIRE main menu, wherein the purpose and general capabilities for each option are furnished. Next, the capabilities and limitations of the software are provided.

  1. Using reference frames and the Global Positioning System (GPS) to produce control networks for spatial data 

    E-Print Network [OSTI]

    Naismith, James Mozeney

    1998-01-01

    for setting base control points that cover very large areas. Data obtained from the International GPS Service for Geodynamics (IGS) is used in conjunction with the International Terrestrial Reference Frame (ITRF) to establish control points anywhere...

  2. Assessment of Effectiveness of Geologic Isolation Systems: REFERENCE SITE INITIAL ASSESSMENT FOR A SALT DOME REPOSITORY

    SciTech Connect (OSTI)

    Harwell,, M. A.; Brandstetter,, A.; Benson,, G. L.; Bradley,, D. J.; Serne,, R. J.; Soldat, J. K; Cole,, C. R.; Deutsch,, W. J.; Gupta,, S. K.; Harwell,, C. C.; Napier,, B. A.; Reisenauer,, A. E.; Prater,, L. S.; Simmons,, C. S.; Strenge,, D. L.; Washburn,, J. F.; Zellmer,, J. T.

    1982-06-01

    As a methodology demonstration for the Office of Nuclear Waste Isolation (ONWI), the Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program conducted an initial reference site analysis of the long-term effectiveness of a salt dome repository. The Hainesville Salt Dome in Texas was chosen to be representative of the Gulf Coast interior salt domes; however, the Hainesville Site has been eliminated as a possible nuclear waste repository site. The data used for this exercise are not adequate for an actual assessment, nor have all the parametric analyses been made that would adequately characterize the response of the geosystem surrounding the repository. Additionally, because this was the first exercise of the complete AEGIS and WASTE Rock Interaction Technology (WRIT) methodology, this report provides the initial opportunity for the methodology, specifically applied to a site, to be reviewed by the community outside the AEGIS. The scenario evaluation, as a part of the methodology demonstration, involved consideration of a large variety of potentially disruptive phenomena, which alone or in concert could lead to a breach in a salt dome repository and to a subsequent transport of the radionuclides to the environment. Without waste- and repository-induced effects, no plausible natural geologic events or processes which would compromise the repository integrity could be envisioned over the one-million-year time frame after closure. Near-field (waste- and repository-induced) effects were excluded from consideration in this analysis, but they can be added in future analyses when that methodology development is more complete. The potential for consequential human intrusion into salt domes within a million-year time frame led to the consideration of a solution mining intrusion scenario. The AEGIS staff developed a specific human intrusion scenario at 100 years and 1000 years post-closure, which is one of a whole suite of possible scenarios. This scenario resulted in the delivery of radionuclidecontaminated brine to the surface, where a portion was diverted to culinary salt for direct ingestion by the existing population. Consequence analyses indicated calculated human doses that would be highly deleterious. Additional analyses indicated that doses well above background would occur from such a scenario t even if it occurred a million years into the future. The way to preclude such an intrusion is for continued control over the repository sitet either through direct institutional control or through the effective passive transfer of information. A secondary aspect of the specific human intrusion scenario involved a breach through the side of the salt dome t through which radionuclides migrated via the ground-water system to the accessible environment. This provided a demonstration of the geotransport methodology that AEGIS can use in actual site evaluations, as well as the WRIT program's capabilities with respect to defining the source term and retardation rates of the radionuclides in the repository. This reference site analysis was initially published as a Working Document in December 1979. That version was distributed for a formal peer review by individuals and organizations not involved in its development. The present report represents a revisiont based in part on the responses received from the external reviewers. Summaries of the comments from the reviewers and responses to these comments by the AEGIS staff are presented. The exercise of the AEGIS methodology was successful in demonstrating the methodologyt and thus t in providing a basis for substantive peer review, in terms of further development of the AEGIS site-applications capability and in terms of providing insight into the potential for consequential human intrusion into a salt dome repository.

  3. Assessment of Effectiveness of Geologic Isolation Systems: REFERENCE SITE INITIAL ASSESSMENT FOR A SALT DOME REPOSITORY

    SciTech Connect (OSTI)

    Harwell,, M. A.; Brandstetter,, A.; Benson,, G. L.; Raymond,, J. R.; Brandley,, D. J.; Serne,, R. J.; Soldat,, J. K.; Cole,, C. R.; Deutsch,, W. J.; Gupta,, S. K.; Harwell,, C. C.; Napier,, B. A.; Reisenauer,, A. E.; Prater,, L. S.; Simmons,, C. S.; Strenge,, D. L.; Washburn,, J. F.; Zellmer,, J. T.

    1982-06-01

    As a methodology demonstration for the Office of Nuclear Waste Isolation (ONWI), the Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program conducted an initial reference site analysis of the long-term effectiveness of a salt dome repository. The Hainesville Salt Dome in Texas was chosen to be representative of the Gulf Coast interior salt domes; however, the Hainesville Site has been eliminated as a possible nuclear waste repository site. The data used for this exercise are not adequate for an actual assessment, nor have all the parametric analyses been made that would adequately characterize the response of the geosystem surrounding the repository. Additionally, because this was the first exercise of the complete AEGIS and WASTE Rock Interaction Technology (WRIT) methodology, this report provides the initial opportunity for the methodology, specifically applied to a site, to be reviewed by the community outside the AEGIS. The scenario evaluation, as a part of the methodology demonstration, involved consideration of a large variety of potentially disruptive phenomena, which alone or in concert could lead to a breach in a salt dome repository and to a subsequent transport of the radionuclides to the environment. Without waste- and repository-induced effects, no plausible natural geologic events or processes which would compromise the repository integrity could be envisioned over the one-million-year time frame after closure. Near-field (waste- and repository-induced) effects were excluded from consideration in this analysis, but they can be added in future analyses when that methodology development is more complete. The potential for consequential human intrusion into salt domes within a million-year time frame led to the consideration of a solution mining intrusion scenario. The AEGIS staff developed a specific human intrusion scenario at 100 years and 1000 years post-closure, which is one of a whole suite of possible scenarios. This scenario resulted in the delivery of radionuclidecontaminated brine to the surface, where a portion was diverted to culinary salt for direct ingestion by the existing population. Consequence analyses indicated calculated human doses that would be highly deleterious. Additional analyses indicated that doses well above background would occur from such a scenario t even if it occurred a million years into the future. The way to preclude such an intrusion is for continued control over the repository sitet either through direct institutional control or through the effective passive transfer of information. A secondary aspect of the specific human intrusion scenario involved a breach through the side of the salt dome t through which radionuclides migrated via the ground-water system to the accessible environment. This provided a demonstration of the geotransport methodology that AEGIS can use in actual site evaluations, as well as the WRIT program's capabilities with respect to defining the source term and retardation rates of the radionuclides in the repository. This reference site analysis was initially published as a Working Document in December 1979. That version was distributed for a formal peer review by individuals and organizations not involved in its development. The present report represents a revisiont based in part on the responses received from the external reviewers. Summaries of the comments from the reviewers and responses to these comments by the AEGIS staff are presented. The exercise of the AEGIS methodology was sUGcessful in demonstrating the methodologyt and thus t in providing a basis for substantive peer review, in terms of further development of the AEGIS site-applications capability and in terms of providing insight into the potential for consequential human intrusion into a salt dome repository.

  4. Preliminary Study of a Vented Attic Radiant Barrier System in Hot, Humid Climates Using Side-by-Side, Full-Scale Test Houses 

    E-Print Network [OSTI]

    Lear, W. E.; Barrup, T. E.; Davis, K. E.

    1987-01-01

    A series of side-by-side tests was performed using two full scale test houses to determine the effectiveness of a Vented Radiant Barrier System (VRBS) in reducing the ceiling heat flux during the summer cooling season in North Florida. Another...

  5. Methodology to Develop and Test an Easy-To-Use Procedure for the Preliminary Selection of High-Performance Systems for Office Buildings in Hot and Humid Climates 

    E-Print Network [OSTI]

    Cho, S.

    2009-01-01

    10: Efficient Hot Water Boiler (from 75% Thermal Efficiency to 95% Thermal Efficiency) ...................... 176? 7.4.11? High-performance Measure 11: Efficient Service Water Heater (from 80% Thermal Efficiency to 85% Thermal Efficiency... were implemented including the energy savings, while the comfort level was maintained based on the ASHRAE comfort zone. In addition to the 14 high-performance measures, solar thermal and solar PV system analysis were integrated with the SGDOE-2.1e...

  6. A passive cooling design for multifamily residences [sic] in hot, humid climates

    E-Print Network [OSTI]

    Tang, Joseph C

    1983-01-01

    People living in hot, humid climates suffer either from extremely uncomfortable weather conditions or from the great cost of air-conditioning systems for maintaining comfort. Most of the available passive cooling techniques ...

  7. Demand Controlled Ventilation for Improved Humidity Control 

    E-Print Network [OSTI]

    Rogers, J. K.

    1996-01-01

    , outside air can be minimized without exceeding recommended IAQ guidelines. INTRODUCTION The greatest single contributor to building energy loads in humid climates is the cooling and dehumidifying of outside air which is brought in for ventilation...

  8. Group 3: Humidity, Temperature, and Voltage

    Broader source: Energy.gov [DOE]

    This PowerPoint presentation, focused on humidity, temperature and voltage testing, was originally presented by John Wohlgemuth at the NREL 2013 PV Module Reliability Workshop on Feb. 26-27, 2013 in Denver, CO. It summarizes the activities of a working group chartered to develop accelerated stress tests that can be used as comparative predictors of module life versus stresses associated with humidity, temperature and voltage.

  9. Energy Efficient Crawlspace Foundation Retrofit: Mixed Humid Climate

    SciTech Connect (OSTI)

    Del Bianco, M.; Wiehagen, J.

    2013-01-01

    Residential quality management systems have most often been designed for new home construction. To address quality in existing homes in the form of Scopes of Work (SOW), the NAHB Research Center began with a new construction scope of work and applied it to an existing home project. This document is intended to outline the steps of translating a new home construction SOW to SOW for retrofit and addressed crawlspace foundations in a mixed-humid climate.

  10. Referring Expression Generation Challenge 2008 DIT System Descriptions J.D. Kelleher

    E-Print Network [OSTI]

    is the mechanism used to order the attributes for inclusion. 1.1 DIT-FBI System The DIT-FBI system selects the next

  11. Product-form solution techniques for the performance analysis of multiple-bus multiprocessor systems with nonuniform memory references

    SciTech Connect (OSTI)

    Chiola, G.; Marsan, M.A.; Balbo, G.

    1988-05-01

    Recursive relations are derived for the exact computation of the steady-state probability distribution of some queueing models with passive resources that can be used to analyze the performance of multiple-bus multiprocessor system architectures. The most general case that was shown to admit a product-form solution is described, and a recursive solution is obtained considering different processor access rates, different memory selection probabilities, and an FCFS bus scheduling policy. Several simpler cases allowing easier model solutions are also considered. Numerical evaluations of large computing systems with nonuniform memory references show the usefulness of the results.

  12. Lanthanide and actinide doped glasses as reference standards for dye doped systems

    SciTech Connect (OSTI)

    Pope, E.J.A.; Hentschel, A.

    1996-12-31

    Organic dye molecules are well known to be subject to chemical and optical bleaching damage, temperature instability, and other forms of optical degradation. Currently recognized methods of referencing rely upon fluorescent salt solutions, such as quinine sulfate. In this paper, optically-active lanthanide and actinide doped gel-glasses are compared as reference standards for dye doped polymers. Samples are subjected to continuous illumination by 254 nm UV radiation. While dye-doped polymers exhibited approximately 65 percent decline in fluorescence intensity after 96 hours of irradiation, glass samples and glass powder in resin showed no decline in fluorescence intensities.

  13. Multisensor-Humidity and Light ApplicationsApplications

    E-Print Network [OSTI]

    Levi, Anthony F. J.

    to control dust mites. For people that suffer from allergies and asthma, relative humidity must be between 45. · Extreme humidity generally is uncomfortable and may cause respiratory complications 6 #12;Humidity Effect materials brittle · High humidity ­ Increases conductivity of permeable insulators ­ Condensation causes

  14. Active Humidity Control Through Gas-Fired Desiccant Humidity Pump 

    E-Print Network [OSTI]

    Novosel, D.; Griffiths, W. C.

    1988-01-01

    to new or existing conventional air-conditioning system via a duct. It consists of a triple integrated heat-exchanger combining (liquid) desiccant dehumidification with indirect evaporative cooling, a brine interchanger, and a gas-fired brine heater...

  15. Humidity effects on wire insulation breakdown strength.

    SciTech Connect (OSTI)

    Appelhans, Leah

    2013-08-01

    Methods for the testing of the dielectric breakdown strength of insulation on metal wires under variable humidity conditions were developed. Two methods, an ASTM method and the twisted pair method, were compared to determine if the twisted pair method could be used for determination of breakdown strength under variable humidity conditions. It was concluded that, although there were small differences in outcomes between the two testing methods, the non-standard method (twisted pair) would be appropriate to use for further testing of the effects of humidity on breakdown performance. The dielectric breakdown strength of 34G copper wire insulated with double layer Poly-Thermaleze/Polyamide-imide insulation was measured using the twisted pair method under a variety of relative humidity (RH) conditions and exposure times. Humidity at 50% RH and below was not found to affect the dielectric breakdown strength. At 80% RH the dielectric breakdown strength was significantly diminished. No effect for exposure time up to 140 hours was observed at 50 or 80%RH.

  16. Expert Meeting: Recommended Approaches to Humidity Control in High Performance Homes

    SciTech Connect (OSTI)

    Rudd, A.

    2013-07-01

    The topic of this Building America expert meeting was 'Recommended Approaches to Humidity Control in High Performance Homes,' which was held on October 16, 2012, in Westford, MA, and brought together experts in the field of residential humidity control to address modeling issues for dehumidification. The presentations and discussions centered on computer simulation and field experience with these systems, with the goal of developing foundational information to support the development of a Building America Measure Guideline on this topic.

  17. Lanthanide-halide based humidity indicators

    DOE Patents [OSTI]

    Beitz, James V. (Hinsdale, IL); Williams, Clayton W. (Chicago, IL)

    2008-01-01

    The present invention discloses a lanthanide-halide based humidity indicator and method of producing such indicator. The color of the present invention indicates the humidity of an atmosphere to which it is exposed. For example, impregnating an adsorbent support such as silica gel with an aqueous solution of the europium-containing reagent solution described herein, and dehydrating the support to dryness forms a substance with a yellow color. When this substance is exposed to a humid atmosphere the water vapor from the air is adsorbed into the coating on the pore surface of the silica gel. As the water content of the coating increases, the visual color of the coated silica gel changes from yellow to white. The color change is due to the water combining with the lanthanide-halide complex on the pores of the gel.

  18. Tools and reference standards supporting the engineering and evolution of synthetic biological systems

    E-Print Network [OSTI]

    Kelly, Jason R. (Jason Robert)

    2008-01-01

    Biological engineers have constructed a number of multi-part synthetic biological systems that conduct logical operations on input signals, produce oscillatory output signals, store memory, or produce desired products. ...

  19. WASTES: Wastes system transportation and economic simulation: Version 2, Programmer's reference manual

    SciTech Connect (OSTI)

    Buxbaum, M.E.; Shay, M.R.

    1986-11-01

    The WASTES Version II (WASTES II) Programmer's Reference Manual was written to document code development activities performed under the Monitored Retrievable Storage (MRS) Program at Pacific Northwest Laboratory (PNL). The manual will also serve as a valuable tool for programmers involved in maintenance of and updates to the WASTES II code. The intended audience for this manual are experienced FORTRAN programmers who have only a limited knowledge of nuclear reactor operation, the nuclear fuel cycle, or nuclear waste management practices. It is assumed that the readers of this manual have previously reviewed the WASTES II Users Guide published as PNL Report 5714. The WASTES II code is written in FORTRAN 77 as an extension to the SLAM commercial simulation package. The model is predominately a FORTRAN based model that makes extensive use of the SLAM file maintenance and time management routines. This manual documents the general manner in which the code is constructed and the interactions between SLAM and the WASTES subroutines. The functionality of each of the major WASTES subroutines is illustrated with ''block flow'' diagrams. The basic function of each of these subroutines, the algorithms used in them, and a discussion of items of particular note in the subroutine are reviewed in this manual. The items of note may include an assumption, a coding practice that particularly applies to a subroutine, or sections of the code that are particularly intricate or whose mastery may be difficult. The appendices to the manual provide extensive detail on the use of arrays, subroutines, included common blocks, parameters, variables, and files.

  20. Group 3: Humidity, Temperature and Voltage (Presentation)

    SciTech Connect (OSTI)

    Wohlgemuth, J.

    2013-09-01

    This is a summary of the work of Group 3 of the International PV QA Task Force. Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

  1. Data Center Economizer Contamination and Humidity Study

    SciTech Connect (OSTI)

    Shehabi, Arman; Tschudi, William; Gadgil, Ashok

    2007-03-06

    Data centers require continuous air conditioning to address high internal heat loads (heat release from equipment) and maintain indoor temperatures within recommended operating levels for computers. Air economizer cycles, which bring in large amounts of outside air to cool internal loads when weather conditions are favorable, could save cooling energy. There is reluctance from many data center owners to use this common cooling technique, however, due to fear of introducing pollutants and potential loss of humidity control. Concerns about equipment failure from airborne pollutants lead to specifying as little outside air as permissible for human occupants. To investigate contamination levels, particle monitoring was conducted at 8 data centers in Northern California. Particle counters were placed at 3 to 4 different locations within and outside of each data center evaluated in this study. Humidity was also monitored at many of the sites to determine how economizers affect humidity control. Results from this study indicate that economizers do increase the outdoor concentration in data centers, but this concentration, when averaged annually, is still below current particle concentration limits. Study results are summarized below: (1) The average particle concentrations measured at each location, both outside and at the servers, are shown in Table 1. Measurements show low particle concentrations at all data centers without economizers, regardless of outdoor particle concentrations. Particle concentrations were typically an order of magnitude below both outside particle concentrations and recently published ASHRAE standards. (2) Economizer use caused sharp increases in particle concentrations when the economizer vents were open. The particle concentration in the data centers, however, quickly dropped back to pre-economizer levels when the vents closed. Since economizers only allow outside air part of the time, the annual average concentrations still met the ASHRAE standards. However, concentration were still above the levels measured in data centers that do not use economizers (3) Current filtration in data centers is minimal (ASHRAE 40%) since most air is typically recycled. When using economizers, modest improvements in filtration (ASHRAE 85%) can reduce particle concentrations to nearly match the level found in data centers that do not use economizers. The extra cost associated with improve filters was not determined in this study. (4) Humidity was consistent and within the ASHRAE recommended levels for all data centers without economizers. Results show that, while slightly less steady, humidity in data centers with economizers can also be controlled within the ASHRAE recommended levels. However, this control of humidity reduces energy savings by limiting the hours the economizer vents are open. (5) The potential energy savings from economizer use has been measured in one data center. When economizers were active, mechanical cooling power dropped by approximately 30%. Annual savings at this center is estimated within the range of 60-80 MWh/year, representing approximately a 5% savings off the mechanical energy load of the data center. Incoming temperatures and humidity at this data center were conservative relative to the ASHRAE acceptable temperature and humidity ranges. Greater savings may be available if higher temperature humidity levels in the data center area were permitted. The average particle concentrations measured at each of the eight data center locations are shown in Table 1. The data centers ranged in size from approximately 5,000 ft{sup 2} to 20,000 ft{sup 2}. The indoor concentrations and humidity in Table 1 represents measurements taken at the server rack. Temperature measurements at the server rack consistently fell between 65-70 F. The Findings section contains a discussion of the individual findings from each center. Data centers currently operate under very low contamination levels. Economizers can be expected to increase the particle concentration in data centers, but the increase appears to still be

  2. Methods And Systems For Using Reference Images In Acoustic Image Processing

    DOE Patents [OSTI]

    Moore, Thomas L. (Livermore, CA); Barter, Robert Henry (Oakland, CA)

    2005-01-04

    A method and system of examining tissue are provided in which a field, including at least a portion of the tissue and one or more registration fiducials, is insonified. Scattered acoustic information, including both transmitted and reflected waves, is received from the field. A representation of the field, including both the tissue and the registration fiducials, is then derived from the received acoustic radiation.

  3. Reference Manual for the System Advisor Model's Wind Power Performance Model

    SciTech Connect (OSTI)

    Freeman, J.; Jorgenson, J.; Gilman, P.; Ferguson, T.

    2014-08-01

    This manual describes the National Renewable Energy Laboratory's System Advisor Model (SAM) wind power performance model. The model calculates the hourly electrical output of a single wind turbine or of a wind farm. The wind power performance model requires information about the wind resource, wind turbine specifications, wind farm layout (if applicable), and costs. In SAM, the performance model can be coupled to one of the financial models to calculate economic metrics for residential, commercial, or utility-scale wind projects. This manual describes the algorithms used by the wind power performance model, which is available in the SAM user interface and as part of the SAM Simulation Core (SSC) library, and is intended to supplement the user documentation that comes with the software.

  4. Temporal and spatial distribution of fishes in the upper Galveston Bay System with particular reference to the cooling water system of Cedar Bayou Generating Station 

    E-Print Network [OSTI]

    Holt, Scott Allen

    1976-01-01

    1I:MPORAL AND SPATIAL DISTRIBUTION OF FISHES IN THE UPPER GALVESTON BAY SYSTEM WITH PARTICULAR REFERENCE TO THE COOLING WATER SYSTEM OF CEDAR BAYOU GENERATING STATION A Thesis by SCOTT ALLEN HOLT Submitted to the Graduate College of Texas A... This research was made possible by a grant from Hou-ton Lighting 6 Power Company to the Department of Wildlife and Fisheries Scier. es and the Texas Agricultural Experiment Station (Project 1869-2781) . I would like to express my appreciation to Dr. Kirk...

  5. Energy Wheel Performance and Optimization Opportunities for SDVAV AHU's In a Hot & Humid Climate 

    E-Print Network [OSTI]

    Zhao, J.; Wang, L.; Watt, J.

    2012-01-01

    The HVAC system accounts for 30 to 50 percent of a typical building's energy consumption; in hot & humid climates it is closer to the upper end of that range. Implementing effective energy saving measures for the building HVAC system can reduce...

  6. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II) by Carbon-RichProtonAbout Us HanfordReference Materials Reference

  7. Reference Shelf

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II) by Carbon-RichProtonAbout Us HanfordReference MaterialsReference Shelf

  8. Poroelastic references

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Christina Morency

    2014-12-12

    This file contains a list of relevant references on the Biot theory (forward and inverse approaches), the double-porosity and dual-permeability theory, and seismic wave propagation in fracture porous media, in RIS format, to approach seismic monitoring in a complex fractured porous medium such as Brady?s Geothermal Field.

  9. Poroelastic references

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Christina Morency

    This file contains a list of relevant references on the Biot theory (forward and inverse approaches), the double-porosity and dual-permeability theory, and seismic wave propagation in fracture porous media, in RIS format, to approach seismic monitoring in a complex fractured porous medium such as Brady?s Geothermal Field.

  10. Ventilation Requirements in Hot Humid Climates 

    E-Print Network [OSTI]

    Walker, I. S.; Sherman, M. H.

    2006-01-01

    ,” To be publicshed ASHRAE Trans. Sherman, M.H. and Matson, N.E “Residential Ventilation and Energy Characteristics,” ASHRAE Trans. 103(1), 1997, [LBNL- 39036]. Sherman M. H., “Over-ventilating in Hot, Humid Climates”, IAQ Applications, 7(1) pp. 1-4 ASHRAE, 2006...a. Sherman M. H. , “House Need to Breathe…Right?” Fine Homebuilding, April/May 2006; pp. 64-69, LBL Report 54496. Sherman M.H, Matson N.E. , “Air Tightness in New U.S. Housing” Proc. 22 nd AIVC Conference, Air Infiltration and Ventilation...

  11. Data Center Economizer Contamination and Humidity Study

    E-Print Network [OSTI]

    Shehabi, Arman

    2010-01-01

    Technologies Program Data Center Economizer ContaminationREFERENCES Executive Summary Data centers require continuousreluctance from many data center owners to use this common

  12. An Analysis of Maximum Residential Energy Efficiency in Hot and Humid Climates 

    E-Print Network [OSTI]

    Malhotra, M.; Haberl, J. S.

    2006-01-01

    Christensen et al. 2005 ? BEopt: software for identifying most cost-effective combination of strategies ? User selected predefined measures Review ESL-HH-06-07-26a Proceedings of the Fifteenth Symposium on Improving Buildling Systems in Hot and Humid...

  13. 4B.1 IMPACTS OF HUMIDITY-CORRECTED SONDE DATA ON TOGA COARE ANALYSES

    E-Print Network [OSTI]

    Wang, Junhong

    occurred over the entire depth of sounding profile, but were largest at low levels. Based on extensive humidity sensor. This error affects the entire sounding profile, increases with the age of the sonde at several key sites generally reported hu- midities too dry. In contrast, the sounding systems around 10 N

  14. Expert Meeting. Recommended Approaches to Humidity Control in High Performance Homes

    SciTech Connect (OSTI)

    Rudd, Armin

    2013-07-01

    This meeting was held on October 16, 2012, in Westford, MA, and brought together experts in the field of residential humidity control to address modeling issues for dehumidification. The presentations and discussions centered on computer simulation and field experience with these systems, with the goal of developing foundational information to support the development of a Building America Measure Guideline on this topic.

  15. An isotopic evaluation of the factors controlling low humidity1 air in the troposphere2

    E-Print Network [OSTI]

    Noone, David

    of Colorado21 Boulder, CO 80309-021622 USA23 Phone: +1-303-735-607324 Fax: +1-303-492-352425 26 #12;2 Abstract descending branch of the Hadley cell mostly contributes to relative humidity through its18 influence of the climate system because2 of its role in absorbing terrestrial radiation, allowing the formation of clouds

  16. A Quick Overview of the Art of Humidity Measurement 

    E-Print Network [OSTI]

    Brownawell, M.

    1989-01-01

    for 300 hours. HUMIDITY Relative humidity is measured in many ways. The expansion and contraction of many materials with changes in relative humidity are well known. This phenomenon is used in the hair hygrometers...

  17. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II) by Carbon-RichProtonAbout Us Hanford SiteRecoveryWatertheReference

  18. Reference Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II) by Carbon-RichProtonAbout Us HanfordReference Materials

  19. Building America Expert Meeting: Recommended Approaches to Humidity...

    Broader source: Energy.gov (indexed) [DOE]

    topic of this Building America expert meeting was Recommended Approaches to Humidity Control in High Performance Homes, which was held on October 16, 2012, in Westford, MA, and...

  20. Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate

    SciTech Connect (OSTI)

    Kerrigan, P.; Norton, P.

    2014-10-01

    This report, Evaluation of the Performance of Houses with and without Supplemental Dehumidification in a Hot-Humid Climate, describes a research study that that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance, homes in a Hot-Humid climate. The purpose of this research project was to observe and compare the humidity control performance of new, single family, low energy, and high performance, homes. Specifically, the study sought to compare the interior conditions and mechanical systems operation between two distinct groups of houses, homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were ten single-family new construction homes in New Orleans, LA.Data logging equipment was installed at each home in 2012. Interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space. However, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.

  1. Electric Field and Humidity Trigger Contact Electrification

    E-Print Network [OSTI]

    Yanzhen Zhang; Thomas Pähtz; Yonghong Liu; Xiaolong Wang; Rui Zhang; Yang Shen; Renjie Ji; Baoping Cai

    2015-01-14

    Here, we study the old problem of why identical insulators can charge one another on contact. We perform several experiments showing that, if driven by a preexisting electric field, charge is transferred between contacting insulators. This happens because the insulator surfaces adsorb small amounts of water from a humid atmosphere. We believe the electric field then separates positively from negatively charged ions prevailing within the water, which we believe to be hydronium and hydroxide ions, such that at the point of contact, positive ions of one insulator neutralize negative ions of the other one, charging both of them. This mechanism can explain for the first time the observation made four decades ago that wind-blown sand discharges in sparks if and only if a thunderstorm is nearby.

  2. Building America Indoor Temperature and Humidity Measurement Protocol

    SciTech Connect (OSTI)

    Engebrecht-Metzger, C.; Norton, P.

    2014-02-01

    When modeling homes using simulation tools, the heating and cooling set points can have a significant impact on home energy use. Every 4 years the Energy Information Administration (EIA) Residential Energy Consumption Survey (RECS) asks homeowners about their heating and cooling set points. Unfortunately, no temperature data is measured, and most of the time, the homeowner may be guessing at this number. Even one degree Fahrenheit difference in heating set point can make a 5% difference in heating energy use! So, the survey-based RECS data cannot be used as the definitive reference for the set point for the 'average occupant' in simulations. The purpose of this document is to develop a protocol for collecting consistent data for heating/cooling set points and relative humidity so that an average set point can be determined for asset energy models in residential buildings. This document covers the decision making process for researchers to determine how many sensors should be placed in each home, where to put those sensors, and what kind of asset data should be taken while they are in the home. The authors attempted to design the protocols to maximize the value of this study and minimize the resources required to achieve that value.

  3. The Building America Indoor Temperature and Humidity Measurement Protocol

    SciTech Connect (OSTI)

    Metzger, C.; Norton, Paul

    2014-02-01

    When modeling homes using simulation tools, the heating and cooling set points can have a significant impact on home energy use. Every four years, the Energy Information Administration (EIA) Residential Energy Consumption Survey (RECS) asks homeowners about their heating and cooling set points. Unfortunately, no temperature data is measured, and most of the time, the homeowner may be guessing at this number. Even one degree Fahrenheit difference in heating set point can make a 5% difference in heating energy use! So, the survey-based RECS data cannot be used as the definitive reference for the set point for the "average occupant" in simulations. The purpose of this document is to develop a protocol for collecting consistent data for heating/cooling set points and relative humidity so that an average set point can be determined for asset energy models in residential buildings. This document covers the decision making process for researchers to determine how many sensors should be placed in each home, where to put those sensors, and what kind of asset data should be taken while they are in the home. The authors attempted to design the protocols to maximize the value of this study and minimize the resources required to achieve that value.

  4. Moisture performance of sealed attics in the mixed-humid climate

    SciTech Connect (OSTI)

    Boudreaux, Philip R; Pallin, Simon B; Jackson, Roderick K

    2013-12-01

    Oak Ridge National Laboratory studied 8 homes in the mixed-humid climate, 4 with vented attics and 4 with sealed attics. ORNL wanted to understand the moisture performance of the sealed attic and how it affected the interior environment. We found that the attic and interior of sealed attic homes were more humid than the attic and interior observed in vented attic homes. This is due to the lack of ventilation in the sealed attic. Historically attics have been vented to dehumidify the attic and interior of the home. A sealed attic design greatly reduces the venting potential and thus this drying pathway and can cause elevated interior moisture over a vented attic home. Despite the elevated attic and interior moisture in the sealed attic homes, so far no mold or material degradation has been found. The roof sheathing moisture content has stayed below 20%, indicating low potential for material degradation. Also the relative humidity at the roof sheathing has stayed within the ASHRAE 160 design criteria except for a short time during the 2011/2012 winter. This was due to a combination of the sealed attic design (minimal venting to the outside) and the duct work not being operated in the attic which usually provides a dehumidification pathway. It was also found that when the humidity was controlled using the HVAC system, it resulted in 7% more cooling energy consumption. In the mixed-humid climate this reduces the cost effectiveness of the sealed attic design as a solution for bringing ducts into a semi-conditioned space. Because of this we are recommending the other alternatives be used to bringing ducts into the conditioned space in both new construction and retrofit work in the mixed-humid climate.

  5. Integrated Temperature and Humidity Control: A Unique Approach 

    E-Print Network [OSTI]

    Shah, D. J.

    2000-01-01

    During hot and humid periods, a comfortable indoor environment can be attained only by controlling both the dry-bulb temperature and the humidity in the space. Conventional thermostats control the ON/OFF status of a cooling plant to maintain only...

  6. Integrated and Optimized Energy-Efficient Construction Package for a Community of Production Homes in the Mixed-Humid Climate

    SciTech Connect (OSTI)

    Mallay, D.; Wiehagen, J.; Del Bianco, M.

    2014-10-01

    Selection and integration of high performance home features are two sides of the same coin in energy efficient sustainable construction. Many advanced technologies are available for selection, but it is in the integration of these technologies into an affordable set of features that can be used on a production basis by builders, that ensures whole-house performance meets expectations. This research high performance home analyzes how a set of advanced technologies can be integrated into a durable and energy efficient house in the mixed-humid climate while remaining affordable to homeowners. The technical solutions documented in this report are the cornerstone of the builder's entire business model based on delivering high-performance homes on a production basis as a standard product offering to all price segments of the residential market. Home Innovation Research Labs partnered with production builder Nexus EnergyHomes (CZ 4). The builder plans to adopt the successful components of the energy solution package for all 55 homes in the community. The research objective was to optimize the builder's energy solution package based on energy performance and construction costs. All of the major construction features, including envelope upgrades, space conditioning system, hot water system, and solar electric system were analyzed. The information in this report can be used by builders and designers to evaluate options, and the integration of options, for increasing the efficiency of home designs in climate zone 4. The data also provide a point of reference for evaluating estimates of energy savings and costs for specific features.

  7. The rest mass of a system of two photons in different inertial reference frames: 0+0=0 and 0+0>0

    E-Print Network [OSTI]

    Berhard Rothenstein; Doru P?unescu; ?tefan Popescu

    2007-08-31

    We show that the rest mass of a system consisting of two photons is a relativistic invariant having the same magnitude in all inertial reference frames in relative motion. A scenario which starts with two photons where theirs frequencies are equal to each other the magnitude of the rest mass of the system depends on the angle made by the momentums of the two photons. The behavior of the photons when detected from two inertial reference frames is illustrated using a relativistic diagram which displays in true values the physical quantities (scalar and vector) introduced in order to characterize the dynamical properties of the photon. We consider that the obtained results should be taken in the discussions, some time fierce, between those who ban the concept of relativistic mass and those who consider that its use is harmless.

  8. Ice Surface Entropy Induction by Humidity or How Humidity Prompts Freezing

    E-Print Network [OSTI]

    Jose Luis Perez-Diaz; Marco Antonio Alvarez-Valenzuela; Juan Sanchez-Garcia-Casarrubios; Sergio Jimenez-Lopez

    2015-09-22

    In this work we measured Surface Energy and Freezing Temperature of supercooled water droplets in air. We find that freezing of water droplets is triggered at the water-air interface and that freezing progresses faster on the surface than in the bulk. The Freezing Point of water droplets is strongly depressed by dryness in air and how humidity triggers freezing. Additionally it is shown to be a Surface phenomenon related to a transfer of Entropy from water vapour to the surface of ice.

  9. Optical probe with reference fiber

    DOE Patents [OSTI]

    Da Silva, Luiz B. (Danville, CA); Chase, Charles L. (Dublin, CA)

    2006-03-14

    A system for characterizing tissue includes the steps of generating an emission signal, generating a reference signal, directing the emission signal to and from the tissue, directing the reference signal in a predetermined manner relative to the emission signal, and using the reference signal to compensate the emission signal. In one embodiment compensation is provided for fluctuations in light delivery to the tip of the probe due to cable motion.

  10. BC TIPS - Hot-Humid Climate: New Orleans

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Hot-Humid Climate: New Orleans Building Technologies Program The U.S. Department of Energy's Builders Challenge recognizes quality homes that also save you money. U.S. homebuilders...

  11. Conquering Moisture and Humidity in Your Home | Department of...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    damaged or clogged with lint. If your dryer duct isn't properly venting this can be dangerous and create higher levels of humidity in your home. Clean out your dryer ducts at...

  12. A tropical grammar : an architectural grammar for hot humid climates

    E-Print Network [OSTI]

    Beamish, Anne, 1954-

    1993-01-01

    This thesis considers the viability of an architectural grammar based on traditional Caribbean architecture as an aid to designing climatically responsive architecture in hot humid climates. It argues that since traditional ...

  13. Solutions to Surgical Suite Temperature and Humidity Control 

    E-Print Network [OSTI]

    Crooks, K. W.

    1996-01-01

    . Relative humidity (RH) must still be controlled at these lower temperatures per code guidelines and poses a major hurdle for facilities located throughout the southeastern United States. Heating, ventilating and air conditioning (HVAC) equipment designed...

  14. Atmospheric Condensation Potential of Windows in Hot, Humid Climates 

    E-Print Network [OSTI]

    El Diasty, R.; Budaiwi, I.

    1992-01-01

    condensation rate has been obtained by utilizing a simplified transient uni-dimensional finite difference model. The results show that this model has enhanced the assessment of the potential for atmospheric condensation on windows in hot, humid climates...

  15. Emergency Preparedness Desk Reference Manual

    E-Print Network [OSTI]

    Patzek, Tadeusz W.

    Emergency Preparedness Desk Reference Manual Important Phone Numbers Medical Emergencies / Hazardous Material Fire Emergencies Vehicle Accidents Evacuation Weather Emergencies Building/System Problem or Failure Threat of Violence Terrorism Interpersonal Emergencies Next Page >>> #12;Important Phone Numbers

  16. Wall Drying in Hot and Humid Climates 

    E-Print Network [OSTI]

    Boone, K.; Weston, T.; Pascual, X.

    2004-01-01

    's ability to dry is not considered during the design or material selection process. No cladding system or installation is perfect, therefore wall systems should be designed with the assumption that some moisture will enter and then consider the effects...

  17. Professional References Ready Reference E-11

    E-Print Network [OSTI]

    Professional References Ready Reference E-11 College of Engineering, Architecture & Technology College of Engineering, Architecture & Technology Career Services Office ATRC 109E Stillwater, OK 74078 requested to do so. Create a separate sheet entitled "References." Print it on the same high quality papers

  18. Heating, Ventilation, and Air Conditioning Design Strategy for a Hot-Humid Production Builder

    SciTech Connect (OSTI)

    Kerrigan, P.

    2014-03-01

    Building Science Corporation (BSC) worked directly with the David Weekley Homes - Houston division to develop a cost-effective design for moving the HVAC system into conditioned space. In addition, BSC conducted energy analysis to calculate the most economical strategy for increasing the energy performance of future production houses in preparation for the upcoming code changes in 2015. This research project addressed the following questions: 1. What is the most cost effective, best performing and most easily replicable method of locating ducts inside conditioned space for a hot-humid production home builder that constructs one and two story single family detached residences? 2. What is a cost effective and practical method of achieving 50% source energy savings vs. the 2006 International Energy Conservation Code for a hot-humid production builder? 3. How accurate are the pre-construction whole house cost estimates compared to confirmed post construction actual cost?

  19. Solar-Powered, Liquid-Desiccant Air Conditioner for Low-Electricity Humidity Control: Report and Summary Report

    SciTech Connect (OSTI)

    Dean, J.; Kozubal, E.; Herrmann, L.; Miller, J.; Lowenstein, A.; Barker, G.; Slayzak, S.

    2012-11-01

    The primary objective of this project was to demonstrate the capabilities of a new high-performance, liquid-desiccant dedicated outdoor air system (DOAS) to enhance cooling efficiency and comfort in humid climates while substantially reducing electric peak demand at Tyndall Air Force Base (AFB), which is 12 miles east of Panama City, Florida.

  20. Building America Case Study: Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate, New Orleans, Louisiana (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-11-01

    This report, Evaluation of the Performance of Houses with and without Supplemental Dehumidification in a Hot-Humid Climate, describes a research study that that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance, homes in a Hot-Humid climate. The purpose of this research project was to observe and compare the humidity control performance of new, single family, low energy, and high performance, homes. Specifically, the study sought to compare the interior conditions and mechanical systems operation between two distinct groups of houses, homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were ten single-family new construction homes in New Orleans, LA. Data logging equipment was installed at each home in 2012. Interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space. However, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.

  1. Humidity Implications for Meeting Residential Ventilation Requirements

    E-Print Network [OSTI]

    by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of the Building Technologies Program operation, such as the lack of dehumidification from typical air conditioning systems at the beginning and Max H. Sherman Environmental Energy Technologies Division April 2007 This work was supported

  2. ANALYSIS OF HUMIDITY HALOS AROUND TRADE WIND CUMULUS CLOUDS

    E-Print Network [OSTI]

    , in addition to those of the clouds themselves, which have an impact on the energy balance of the atmosphereANALYSIS OF HUMIDITY HALOS AROUND TRADE WIND CUMULUS CLOUDS M.-L. Lu, J. Wang, A. Freedman, H. H [vol. 60, 1041-1059 (2003)] Environmental Sciences Department Atmospheric Sciences Division Brookhaven

  3. Cattle Production Practices in Grazed Watersheds of the Humid Region

    E-Print Network [OSTI]

    1 Cattle Production Practices in Grazed Watersheds of the Humid Region USDA Proposal Number 2001 Section 406 Integrated Research, Education, and Extension grant for a two-year period to study cattle than 600,000 cattle position points were collected over eight GPS data collection periods spanning two

  4. Humidity-resistant ambient-temperature solid-electrolyte amperometric sensing apparatus

    DOE Patents [OSTI]

    Zaromb, S.

    1994-06-21

    Apparatus and methods for detecting selected chemical compounds in air or other gas streams at room or ambient temperature includes a liquid-free humidity-resistant amperometric sensor comprising a sensing electrode and a counter and reference electrode separated by a solid electrolyte. The sensing electrode preferably contains a noble metal, such as Pt black. The electrolyte is water-free, non-hygroscopic, and substantially water-insoluble, and has a room temperature ionic conductivity [>=]10[sup [minus]4] (ohm-cm)[sup [minus]1], and preferably [>=]0.01 (ohm-cm)[sup [minus]1]. The conductivity may be due predominantly to Ag[sup +] ions, as in Ag[sub 2]WO[sub 4], or to F[sup [minus

  5. Effect of Return Air Leakage on Air Conditioner Performance in Hot/Humid Climates 

    E-Print Network [OSTI]

    O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S.

    1996-01-01

    An experimental study was conducted to quantify the effect of return air leakage from hot/humid attic spaces on the performance of a residential air conditioner. Tests were conducted in psychrometric facilities where temperatures and humidities...

  6. Improving Comfort in Hot-Humid Climates with a Whole-House Dehumidifier, Windermere, Florida (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-11-01

    Maintaining comfort in a home can be challenging in hot-humid climates. At the common summer temperature set point of 75 degrees F, the perceived air temperature can vary by 11 degrees F because higher indoor humidity reduces comfort. Often the air conditioner (AC) thermostat set point is lower than the desirable cooling level to try to increase moisture removal so that the interior air is not humid or "muggy." However, this method is not always effective in maintaining indoor relative humidity (RH) or comfort. In order to quantify the performance of a combined whole-house dehumidifier (WHD) AC system, researchers from the U.S. Department of Energy's Building America team Consortium of Advanced Residential Buildings (CARB) monitored the operation of two Lennox AC systems coupled with a Honeywell DH150 TrueDRY whole-house dehumidifier for a six-month period. By using a WHD to control moisture levels (latent cooling) and optimizing a central AC to control temperature (sensible cooling), improvements in comfort can be achieved while reducing utility costs. Indoor comfort for this study was defined as maintaining indoor conditions at below 60% RH and a humidity ratio of 0.012 lbm/lbm while at common dry bulb set point temperatures of 74 degrees -80 degrees F. In addition to enhanced comfort, controlling moisture to these levels can reduce the risk of other potential issues such as mold growth, pests, and building component degradation. Because a standard AC must also reduce dry bulb air temperature in order to remove moisture, a WHD is typically needed to support these latent loads when sensible heat removal is not desired.

  7. Emergency Information Desk Reference

    E-Print Network [OSTI]

    Gopalakrishnan, K.

    Emergency Information Desk Reference ECU Police Department ECU Environmental Health & Safety Revised Feb 2012 #12;Emergency Information Desk Reference 2 INTRODUCTION Emergencies, accidents, and injuries can occur at any time and without warning. ECU has designed this emergency information desk

  8. Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate

    SciTech Connect (OSTI)

    Kerrigan, P.

    2014-10-01

    This report describes a research study that was conducted by the Building Science Corporation (BSC) Building America Research Team. BSC seeks to research and report on the field monitoring of the performance of in-situ supplemental dehumidification systems in low energy, high performance homes in a hot-humid climate. The purpose of this research project was to observe and compare the humidity control performance. Specifically, the study sought to compare the interior conditions and mechanical systems operation between two distinct groups of houses; homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were 10 single-family, new construction homes in New Orleans, LA.

  9. IMPACT OF ARM RADIOSONDE HUMIDITY CORRECTION ON CALCULATION OF CONVECTIVE INDICES

    E-Print Network [OSTI]

    IMPACT OF ARM RADIOSONDE HUMIDITY CORRECTION ON CALCULATION OF CONVECTIVE INDICES David Troyan the course of the history of the ARM and ASR Programs, there have been efforts to improve the humidity of humidity calibration in ARM- used Vaisala soundings. Determining additional problems, devising

  10. Holocene climate instability during the termination of the African Humid Period

    E-Print Network [OSTI]

    Renssen, Hans

    Holocene climate instability during the termination of the African Humid Period H. Renssen January 2003; published 25 February 2003. [1] The termination of the Holocene African Humid Period ($9. Goosse, Holocene climate instability during the termination of the African Humid Period, Geophys. Res

  11. Heating, Ventilation, and Air Conditioning Design Strategy for a Hot-Humid Production Builder

    SciTech Connect (OSTI)

    Kerrigan, P.

    2014-03-01

    BSC worked directly with the David Weekley Homes - Houston division to redesign three floor plans in order to locate the HVAC system in conditioned space. The purpose of this project is to develop a cost effective design for moving the HVAC system into conditioned space. In addition, BSC conducted energy analysis to calculate the most economical strategy for increasing the energy performance of future production houses. This is in preparation for the upcoming code changes in 2015. The builder wishes to develop an upgrade package that will allow for a seamless transition to the new code mandate. The following research questions were addressed by this research project: 1. What is the most cost effective, best performing and most easily replicable method of locating ducts inside conditioned space for a hot-humid production home builder that constructs one and two story single family detached residences? 2. What is a cost effective and practical method of achieving 50% source energy savings vs. the 2006 International Energy Conservation Code for a hot-humid production builder? 3. How accurate are the pre-construction whole house cost estimates compared to confirmed post construction actual cost? BSC and the builder developed a duct design strategy that employs a system of dropped ceilings and attic coffers for moving the ductwork from the vented attic to conditioned space. The furnace has been moved to either a mechanical closet in the conditioned living space or a coffered space in the attic.

  12. HVAC Design Strategy for a Hot-Humid Production Builder, Houston, Texas (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-03-01

    BSC worked directly with the David Weekley Homes - Houston division to redesign three floor plans in order to locate the HVAC system in conditioned space. The purpose of this project is to develop a cost effective design for moving the HVAC system into conditioned space. In addition, BSC conducted energy analysis to calculate the most economical strategy for increasing the energy performance of future production houses. This is in preparation for the upcoming code changes in 2015. The builder wishes to develop an upgrade package that will allow for a seamless transition to the new code mandate. The following research questions were addressed by this research project: 1. What is the most cost effective, best performing and most easily replicable method of locating ducts inside conditioned space for a hot-humid production home builder that constructs one and two story single family detached residences? 2. What is a cost effective and practical method of achieving 50% source energy savings vs. the 2006 International Energy Conservation Code for a hot-humid production builder? 3. How accurate are the pre-construction whole house cost estimates compared to confirmed post construction actual cost? BSC and the builder developed a duct design strategy that employs a system of dropped ceilings and attic coffers for moving the ductwork from the vented attic to conditioned space. The furnace has been moved to either a mechanical closet in the conditioned living space or a coffered space in the attic.

  13. Performance Evaluation of a Hot-Humid Climate Community

    SciTech Connect (OSTI)

    Osser, R.; Kerrigan, P.

    2012-02-01

    Project Home Again is a development in New Orleans, LA created to provide new homes to victims of Hurricane Katrina. Building Science Corporation acted as a consultant for the project, advocating design strategies for durability, flood resistance, occupant comfort, and low energy use while maintaining cost effectiveness. These techniques include the use of high density spray foam insulation, LoE3 glazing, and supplemental dehumidification to maintain comfortable humidity levels without unnecessary cooling.

  14. References: Elmasri/Navathe:Fundamentals

    E-Print Network [OSTI]

    Brass, Stefan

    7. SQL I 7­1 Part 7: SQL I References: . Elmasri/Navathe:Fundamentals of Database Systems, 3rd Edition, 1999. Chap. 8, ``SQL --- The Relational Database Standard'' (Sect. 8.2, 8.3.3, part of 8. . Date/Darwen: A Guide to the SQL Standard, Fourth Edition, Addison­Wesley , 1997. . Date: A Guide

  15. Humidity-resistant ambient-temperature solid-electrolyte amperometric sensing apparatus and methods

    DOE Patents [OSTI]

    Zaromb, Solomon (9 S 706 William Dr., Hinsdale, IL 60521)

    2001-01-01

    Apparatus and methods for detecting selected chemical compounds in air or other gas streams at room or ambient temperature includes a liquid-free humidity-resistant amperometric sensor comprising a sensing electrode and a counter and reference electrode separated by a solid electrolyte. The sensing electrode preferably contains a noble metal, such as Pt black. The electrolyte is water-free, non-hygroscopic, and substantially water-insoluble, and has a room temperature ionic conductivity .gtoreq.10.sup.-4 (ohm-cm).sup.-1, and preferably .gtoreq.0.01 (ohm-cm).sup.-1. The conductivity may be due predominantly to Ag+ ions, as in Ag.sub.2 WO.sub.4.4AgI, or to F- ions, as in Ce.sub.0.95 Ca.sub.0.05 F.sub.2.95. Electrical contacts serve to connect the electrodes to potentiostating and detecting circuitry which controls the potential of the sensing electrode relative to the reference electrode, detects the signal generated by the sensor, and indicates the detected signal.

  16. Sensor Characteristics Reference Guide

    SciTech Connect (OSTI)

    Cree, Johnathan V.; Dansu, A.; Fuhr, P.; Lanzisera, Steven M.; McIntyre, T.; Muehleisen, Ralph T.; Starke, M.; Banerjee, Pranab; Kuruganti, T.; Castello, C.

    2013-04-01

    The Buildings Technologies Office (BTO), within the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), is initiating a new program in Sensor and Controls. The vision of this program is: • Buildings operating automatically and continuously at peak energy efficiency over their lifetimes and interoperating effectively with the electric power grid. • Buildings that are self-configuring, self-commissioning, self-learning, self-diagnosing, self-healing, and self-transacting to enable continuous peak performance. • Lower overall building operating costs and higher asset valuation. The overarching goal is to capture 30% energy savings by enhanced management of energy consuming assets and systems through development of cost-effective sensors and controls. One step in achieving this vision is the publication of this Sensor Characteristics Reference Guide. The purpose of the guide is to inform building owners and operators of the current status, capabilities, and limitations of sensor technologies. It is hoped that this guide will aid in the design and procurement process and result in successful implementation of building sensor and control systems. DOE will also use this guide to identify research priorities, develop future specifications for potential market adoption, and provide market clarity through unbiased information

  17. Appeared in Sensors and Actuators B: Chemical, vol. 114, no. 1, pp. 254-262, 30 March 2006 Compliant and Low-cost Humidity Sensors using

    E-Print Network [OSTI]

    Sitti, Metin

    inexpensively on various types of nano-porous polymer membranes such as polycarbonate, cellulose acetate. Keywords: Humidity sensor; Nanoporous membrane; Polycarbonate; Shadow mask; 1. INTRODUCTION Humidity humidity sensors. Resistive humidity sensors usually consist of a moisture-sensitive, conductive material

  18. High frequency reference electrode

    DOE Patents [OSTI]

    Kronberg, J.W.

    1994-05-31

    A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or halo' at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes. 4 figs.

  19. High frequency reference electrode

    DOE Patents [OSTI]

    Kronberg, James W. (Aiken, SC)

    1994-01-01

    A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or "halo" at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes.

  20. Optical voltage reference

    DOE Patents [OSTI]

    Rankin, R.; Kotter, D.

    1994-04-26

    An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

  1. Optical voltage reference

    DOE Patents [OSTI]

    Rankin, Richard (Ammon, ID); Kotter, Dale (Bingham County, ID)

    1994-01-01

    An optical voltage reference for providing an alternative to a battery source. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function.

  2. Sandia Energy - Reference Model Documents

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Documents Home Stationary Power Energy Conversion Efficiency Water Power Reference Model Project (RMP) Reference Model Documents Reference Model DocumentsTara Camacho-Lopez2015-05-...

  3. Application Protocol Reference Architecture Application Protocol Reference Architecture

    E-Print Network [OSTI]

    van Sinderen, Marten

    Application Protocol Reference Architecture 165 Chapter 7 Application Protocol Reference Architecture This chapter proposes an alternative reference architecture for application protocols. The proposed reference architecture consists of the set of possible architectures for application protocols

  4. Effect of residential air-to-air heat and moisture exchangers on indoor humidity

    SciTech Connect (OSTI)

    Barringer, C.G.; McGugan, C.A. )

    1989-01-01

    A project was undertaken to develop guidelines for the selection of residential heat and moisture recovery ventilation systems (HRVs) in order to maintain an acceptable indoor humidity for various climatic conditions. These guidelines were developed from reviews on ventilation requirements, HRV performance specifications, and from computer modeling. Space conditions within three house/occupancy models for several types of HRV were simulated for three climatic conditions (Lake Charles, LA; Seattle, WA; and Winnipeg, MB) in order to determine the impact of the HRVs on indoor relative humidity and space-conditioning loads. Results show that when reduction of cooling cost is the main consideration, exchangers with moisture recovery are preferable to sensible HRVs. For reduction of heating costs, moisture recovery should be done for ventilation rates greater than about 15 L/s and average winter temperatures less than about (minus) 10{degrees}C if internal moisture generation rates are low. For houses with higher ventilation rates and colder average winter temperatures, exchangers with moisture recovery should be used.

  5. Building for the Pacific Rim Countries. Energy-efficient building strategies for hot, humid climates

    SciTech Connect (OSTI)

    Sheinkopf, K.

    1991-09-01

    This book has been published by the Solar Energy Industries Association (SEIA), the US trade association of the solar thermal, photovoltaic, and passive solar manufacturers, distributors, and component suppliers. Its purpose is to help architects, builders, and developers construct energy-efficient homes in hot humid climates like the Pacific Rim Countries, and to allow occupants of these homes to enjoy enhanced comfort without reliance on mechanical air-conditioning systems. Two important factors are addressed in this book. First, the past few years have seen a tremendous increase in practical applications of new research. The current popularity of ceiling paddle fans, attic radiant barriers and natural daylighting attest to the importance of keeping up with the latest concepts in energy-reduction and comfort-awareness. Professionals who have been in the field for the past few years may be unaware of the latest research findings--some of which dramatically alter prior thinking on such subjects as natural ventilation or mechanical air conditioning. The second factor is the importance of site-specific characteristics, which greatly affect building strategies and designs. A thorough understanding of the climate is a prerequisite to good building design. Such factors as temperature, humidity, wind speed and direction, and solar radiation must be understood and properly integrated into the design for the home to be truly energy-efficient.

  6. HAZARDOUS WASTE MANAGEMENT REFERENCE

    E-Print Network [OSTI]

    Winfree, Erik

    HAZARDOUS WASTE MANAGEMENT REFERENCE GUIDE Prepared by Environment, Health and Safety Office@caltech.edu http://safety.caltech.edu #12;Hazardous Waste Management Reference Guide Page 2 of 36 TABLE OF CONTENTS Satellite Accumulation Area 9 Waste Accumulation Facility 10 HAZARDOUS WASTE CONTAINER MANAGEMENT Labeling

  7. Reference Hashed Frank Schilder

    E-Print Network [OSTI]

    provides the reader with an introduction to hashing lists and how they can be used for linguistic dam data structure for the representation of discourse referents. A so-called hashing list is employed instead a novel data structure for the representation of discourse referents. A/rushing list t

  8. Impact of Residential Mechanical Ventilation on Energy Cost and Humidity Control

    SciTech Connect (OSTI)

    Martin, Eric

    2014-01-01

    Optimizing whole house mechanical ventilation as part of the Building Ameerica program's systems engineered approach to constructing housing has been an important subject of the program's research. Ventilation in residential buildings is one component of an effective, comprehensive strategy for creation and maintenance of a comfortable and healthy indoor air environment. The study described in this report is based on building energy modeling with an important focus on the indoor humidity impacts of ventilation. The modeling tools used were EnergyPlus version 7.1 (E+) and EnergyGauge USA (EGUSA). Twelve U.S. cities and five climate zones were represented. A total of 864 simulations (2*2*3*3*12= 864) were run using two building archetypes, two building leakage rates, two building orientations, three ventilation systems, three ventilation rates, and twelve climates.

  9. Impact of Residential Mechanical Ventilation on Energy Cost and Humidity Control

    SciTech Connect (OSTI)

    Martin, E.

    2014-01-01

    The DOE Building America program has been conducting research leading to cost effective high performance homes since the early 1990's. Optimizing whole house mechanical ventilation as part of the program's systems engineered approach to constructing housing has been an important subject of the program's research. Ventilation in residential buildings is one component of an effective, comprehensive strategy for creation and maintenance of a comfortable and healthy indoor air environment. The study described in this white paper is based on building energy modeling with an important focus on the indoor humidity impacts of ventilation. The modeling tools used were EnergyPlus version 7.1 (E+) and EnergyGauge USA (EGUSA). Twelve U.S. cities and five climate zones were represented. A total of 864 simulations (2*2*3*3*12= 864) were run using two building archetypes, two building leakage rates, two building orientations, three ventilation systems, three ventilation rates, and twelve climates.

  10. Microgrid cyber security reference architecture.

    SciTech Connect (OSTI)

    Veitch, Cynthia K.; Henry, Jordan M.; Richardson, Bryan T.; Hart, Derek H.

    2013-07-01

    This document describes a microgrid cyber security reference architecture. First, we present a high-level concept of operations for a microgrid, including operational modes, necessary power actors, and the communication protocols typically employed. We then describe our motivation for designing a secure microgrid; in particular, we provide general network and industrial control system (ICS)-speci c vulnerabilities, a threat model, information assurance compliance concerns, and design criteria for a microgrid control system network. Our design approach addresses these concerns by segmenting the microgrid control system network into enclaves, grouping enclaves into functional domains, and describing actor communication using data exchange attributes. We describe cyber actors that can help mitigate potential vulnerabilities, in addition to performance bene ts and vulnerability mitigation that may be realized using this reference architecture. To illustrate our design approach, we present a notional a microgrid control system network implementation, including types of communica- tion occurring on that network, example data exchange attributes for actors in the network, an example of how the network can be segmented to create enclaves and functional domains, and how cyber actors can be used to enforce network segmentation and provide the neces- sary level of security. Finally, we describe areas of focus for the further development of the reference architecture.

  11. PVWatts Version 1 Technical Reference

    SciTech Connect (OSTI)

    Dobos, A. P.

    2013-10-01

    The NREL PVWatts(TM) calculator is a web application developed by the National Renewable Energy Laboratory (NREL) that estimates the electricity production of a grid-connected photovoltaic system based on a few simple inputs. PVWatts combines a number of sub-models to predict overall system performance, and makes several hidden assumptions about performance parameters. This technical reference details the individual sub-models, documents assumptions and hidden parameters, and explains the sequence of calculations that yield the final system performance estimation.

  12. Effect of humid air exposure on photoemissive and structural properties of KBr thin film photocathode

    E-Print Network [OSTI]

    Rai, R; Ghosh, N; Singh, B K

    2014-01-01

    We have investigated the influence of water molecule absorption on photoemissive and structural properties of potassium bromide (KBr) thin film photocathode under humid air exposure at relative humidity (RH) 65%. It is evident from photoemission measurement that the photoelectron yield of KBr photocathode is degraded exponentially with humid air exposed time. Structural studies of the "as-deposited" and "humid air aged" films reveal that there is no effect of RH on film's crystalline face centered cubic (fcc) structure. However, the average crystallite size of "humid air exposed film" KBr film has been increased as compared to "as-deposited". In addition, topographical properties of KBr film are also examined by means of scanning electron microscope (SEM), transmission electron microscope (TEM) and atomic force microscope (AFM) and it is observed that granular characteristic of film has been altered, even for short exposure to humid air.

  13. Value of Information References

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Morency, Christina

    2014-12-12

    This file contains a list of relevant references on value of information (VOI) in RIS format. VOI provides a quantitative analysis to evaluate the outcome of the combined technologies (seismology, hydrology, geodesy) used to monitor Brady's Geothermal Field.

  14. Value of Information References

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Morency, Christina

    This file contains a list of relevant references on value of information (VOI) in RIS format. VOI provides a quantitative analysis to evaluate the outcome of the combined technologies (seismology, hydrology, geodesy) used to monitor Brady's Geothermal Field.

  15. Clause chaining, switch reference and coordination

    E-Print Network [OSTI]

    Nonato, Rafael

    2014-01-01

    In this thesis I ponder over a constellation of phenomena that revolve around switch reference and coordination, drawing mainly on their instantiation in Kisedje (Je, Brazil). I start by investigating Klsedje's case system. ...

  16. Efficient Multifamily Homes in a Hot-Humid Climate by Atlantic Housing Partners

    SciTech Connect (OSTI)

    Chasar, D.; Martin, E.

    2013-04-01

    With assistance from the Florida Solar Energy Center (FSEC) and its Building America Partnership for Improved Residential Construction (BA-PIRC), Atlantic Housing Partners (AHP) has implemented a high performance, systems engineered package of measures. This report demonstrates how the initiative achieves Building America (BA) goals of 30%-50% energy savings. Specifically, the goals are documented as being achieved in the new construction multifamily housing sector in the hot humid climate. Results from energy modeling of the high performance package are presented. The role of utility allowance calculations, used as part of the low-income housing tax credit process, to value those energy savings is discussed, as is customer satisfaction with heat pump water heaters.

  17. Efficient Multifamily Homes in a Hot Humid Climate by Atlantic Housing Partners

    SciTech Connect (OSTI)

    Chaser, Dave; Martin, Eric

    2013-04-01

    With assistance from the Florida Solar Energy Center (FSEC) and its Building America Partnership for Improved Residential Construction (BA-PIRC), Atlantic Housing Partners (AHP) has implemented a high performance, systems engineered package of measures. This report demonstrates how the initiative achieves Building America (BA) goals of 30%-50% energy savings. Specifically, the goals are documented as being achieved in the new construction multifamily housing sector in the hot humid climate. Results from energy modeling of the high performance package are presented. The role of utility allowance calculations, used as part of the low-income housing tax credit process, to value those energy savings is discussed, as is customer satisfaction with heat pump water heaters.

  18. Aluminum reference electrode

    DOE Patents [OSTI]

    Sadoway, Donald R. (Belmont, MA)

    1988-01-01

    A stable reference electrode for use in monitoring and controlling the process of electrolytic reduction of a metal. In the case of Hall cell reduction of aluminum, the reference electrode comprises a pool of molten aluminum and a solution of molten cryolite, Na.sub.3 AlF.sub.6, wherein the electrical connection to the molten aluminum does not contact the highly corrosive molten salt solution. This is accomplished by altering the density of either the aluminum (decreasing the density) or the electrolyte (increasing the density) so that the aluminum floats on top of the molten salt solution.

  19. Aluminum reference electrode

    DOE Patents [OSTI]

    Sadoway, D.R.

    1988-08-16

    A stable reference electrode is described for use in monitoring and controlling the process of electrolytic reduction of a metal. In the case of Hall cell reduction of aluminum, the reference electrode comprises a pool of molten aluminum and a solution of molten cryolite, Na[sub 3]AlF[sub 6], wherein the electrical connection to the molten aluminum does not contact the highly corrosive molten salt solution. This is accomplished by altering the density of either the aluminum (decreasing the density) or the electrolyte (increasing the density) so that the aluminum floats on top of the molten salt solution. 1 fig.

  20. Multifunctional reference electrode

    DOE Patents [OSTI]

    Redey, L.; Vissers, D.R.

    1981-12-30

    A multifunctional, low mass reference electrode of a nickel tube, thermocouple means inside the nickel tube electrically insulated therefrom for measuring the temperature thereof, a housing surrounding the nickel tube, an electrolyte having a fixed sulfide ion activity between the housing and the outer surface of the nickel tube forming the nickel/nickel sulfide/sulfide half-cell are described. An ion diffusion barrier is associated with the housing in contact with the electrolyte. Also disclosed is a cell using the reference electrode to measure characteristics of a working electrode.

  1. Understanding the Temperature and Humidity Environment Inside a PV Module (Presentation), NREL (National Renewable Energy Laboratory)

    Office of Energy Efficiency and Renewable Energy (EERE)

    This PowerPoint presentation was originally given by Michael Kempe of NREL in February 2013 detailing a project funded by the SunShot Initiative. Understanding the Temperature and Humidity Environment Inside a PV Module aims to show that by choosing humidity conditions that more closely match the use environment, one can minimize the uncertainty associated with moisture induced degradation modes.

  2. Grant Reference Lead / Sole

    E-Print Network [OSTI]

    Rank Overall Score Grant Reference Lead / Sole Grant Grant Holder Research Organisation Project of Birmingham Controls on Soil Carbon Export revealed by Novel Tracers on multiple timescales (SCENT) Standard Grant DEC12 8 8 NE/K011871/1 N Melanie Leng NERC British Geological Survey A 500,000-year environmental

  3. Selected data for low-temperature (less than 90{sup 0}C) geothermal systems in the United States: reference data for US Geological Survey Circular 892

    SciTech Connect (OSTI)

    Reed, M.J.; Mariner, R.H.; Brook, C.A.; Sorey, M.L.

    1983-12-15

    Supporting data are presented for the 1982 low-temperature geothermal resource assessment of the United States. Data are presented for 2072 geothermal sites which are representative of 1168 low-temperature geothermal systems identified in 26 States. The low-temperature geothermal systems consist of 978 isolated hydrothermal-convection systems, 148 delineated-area hydrothermal-convection systems, and 42 delineated-area conduction-dominated systems. The basic data and estimates of reservoir conditions are presented for each geothermal system, and energy estimates are given for the accessible resource base, resource, and beneficial heat for each isolated system.

  4. REFERENCES AND RESOURCES SECTION A. REFERENCES

    E-Print Network [OSTI]

    US Army Corps of Engineers

    ANSI/ASME A17.1 Safety Code for Elevators and Escalators ANSI/ASME B30.2 Overhead and Gantry Cranes Training ANSI Z535.1 Safety Color Code ANSI Z535.2 Environmental and Facility Safety Signs ANSI Z535C Specification for Offshore Cranes ANSI/ASME A13.1 Scheme for the Identification of Piping Systems

  5. Citation/Reference Installe AJF, Van den Bosch T, De Moor B, Timmerman D, (2014), Clinical Data Miner: An electronic Case Report Form system with

    E-Print Network [OSTI]

    2014-01-01

    Miner: An electronic Case Report Form system with integrated data preprocessing and machine Paper Clinical Data Miner: An Electronic Case Report Form System With Integrated Data Preprocessing of Clinical Data Miner (CDM) software framework is to offer an eCRF system with integrated data preprocessing

  6. OSH technical reference manual

    SciTech Connect (OSTI)

    Not Available

    1993-11-01

    In an evaluation of the Department of Energy (DOE) Occupational Safety and Health programs for government-owned contractor-operated (GOCO) activities, the Department of Labor`s Occupational Safety and Health Administration (OSHA) recommended a technical information exchange program. The intent was to share written safety and health programs, plans, training manuals, and materials within the entire DOE community. The OSH Technical Reference (OTR) helps support the secretary`s response to the OSHA finding by providing a one-stop resource and referral for technical information that relates to safe operations and practice. It also serves as a technical information exchange tool to reference DOE-wide materials pertinent to specific safety topics and, with some modification, as a training aid. The OTR bridges the gap between general safety documents and very specific requirements documents. It is tailored to the DOE community and incorporates DOE field experience.

  7. Short-Term Test Results. Transitional Housing Energy Efficiency Retrofit in the Hot Humid Climate

    SciTech Connect (OSTI)

    Sutherland, K.

    2013-02-01

    This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30%-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

  8. Short-Term Test Results: Transitional Housing Energy Efficiency Retrofit in the Hot-Humid Climate

    SciTech Connect (OSTI)

    Sutherland, K.; Martin, E.

    2013-02-01

    This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

  9. CVEN 6960 master's project, investigation of a cooling coil in high humidity conditions. Master's thesis

    SciTech Connect (OSTI)

    Sloop, R.E.

    1993-12-10

    The primary purpose of this project is to validate the HVAC*2 Toolkit calculations for a cooling coil in high humidity conditions. A total of 19 experimental runs at different entering air temperature and humidity conditions were performed at the Joint Center for Energy Management HVAC Laboratory that exposed a cooling coil to temperature and humidity conditions that are typically found in the southern United States. The inlet conditions and manufacturer's coil rating data was used as input to the HVAC*2 Toolkit simple cooling coil subroutine (CCSIM). The predicted results from the toolkit were then compared to the experimental results.

  10. Appendix A: Reference case

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet)Decade Year-0ProvedDecade2,948 2,724 2,570Month PreviousDry4,645 8244 Reference

  11. Appendix A: Reference case

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet)Decade Year-0ProvedDecade2,948 2,724 2,570Month PreviousDry4,645 8244 Reference6

  12. Appendix A: Reference case

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet)Decade Year-0ProvedDecade2,948 2,724 2,570Month PreviousDry4,645 8244 Reference64

  13. Appendix A: Reference case

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet)Decade Year-0ProvedDecade2,948 2,724 2,570Month PreviousDry4,645 82444 Reference

  14. Appendix A: Reference case

    Gasoline and Diesel Fuel Update (EIA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustments (Billion Cubic Feet)Decade Year-0ProvedDecade2,948 2,724 2,570Month PreviousDry4,645 82444 Reference6

  15. Manufacturing Energy and Carbon Footprint References | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    References Manufacturing Energy and Carbon Footprint References footprintreferences.pdf More Documents & Publications 2010 Manufacturing Energy and Carbon Footprints: References...

  16. Coal data: A reference

    SciTech Connect (OSTI)

    Not Available

    1995-02-01

    This report, Coal Data: A Reference, summarizes basic information on the mining and use of coal, an important source of energy in the US. This report is written for a general audience. The goal is to cover basic material and strike a reasonable compromise between overly generalized statements and detailed analyses. The section ``Supplemental Figures and Tables`` contains statistics, graphs, maps, and other illustrations that show trends, patterns, geographic locations, and similar coal-related information. The section ``Coal Terminology and Related Information`` provides additional information about terms mentioned in the text and introduces some new terms. The last edition of Coal Data: A Reference was published in 1991. The present edition contains updated data as well as expanded reviews and additional information. Added to the text are discussions of coal quality, coal prices, unions, and strikes. The appendix has been expanded to provide statistics on a variety of additional topics, such as: trends in coal production and royalties from Federal and Indian coal leases, hours worked and earnings for coal mine employment, railroad coal shipments and revenues, waterborne coal traffic, coal export loading terminals, utility coal combustion byproducts, and trace elements in coal. The information in this report has been gleaned mainly from the sources in the bibliography. The reader interested in going beyond the scope of this report should consult these sources. The statistics are largely from reports published by the Energy Information Administration.

  17. An Experimental Evaluation of Duct-Mounted Relative Humidity Sensors: Part 2 – Accuracy Results 

    E-Print Network [OSTI]

    Joshi, S.N.; Pate, M.B.; Nelson, R.M; House, J.H.; Klaasen, C.J.

    2005-01-01

    Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. An Experimental Evaluation of Duct-Mounted Relative Humidity Sensors: Part 2-Accuracy Results Joshi, Shailesh N;House, John M;Pate, Michael B...

  18. Field experiments on occupant comfort and office thermal environments in a hot-humid climate

    E-Print Network [OSTI]

    de Dear, Richard; Fountain, M.

    1994-01-01

    responses to the thermal environment in offices. In Indoorto the thermal environment. ASHRAE Transactions 92(2B):COMFORT AND OFFICE THERMAL ENVIRONMENTS IN A HOT-HUMID

  19. Development and Construction of Bioclimatic Double Skin Active Facade for Hot and Humid Climate of UAE 

    E-Print Network [OSTI]

    Karbor, R. G.; Mohamed, I.

    2010-01-01

    become still more advanced. The present paper deals with the development and construction of mechanically ventilated double skin facade with HVAC integration for hot and humid climate like UAE. A case study is presented, illustrating potential benefits...

  20. Critical Plane Analysis of Wall Assembly in a Hot, Humid Climate 

    E-Print Network [OSTI]

    Turner, S. C.

    2000-01-01

    assemblies are given in 1997 ASHRAE Fundamentals Handbook, Chapter 22 "Thermal and Moisture Control in Insulated Assemblies - Fundamentals." Little original work is available elsewhere in the literature to guide analysis for buildings in hot and humid...

  1. V&A Medieval & Renaissance Galleries: A Passive Approach to Humidity Control 

    E-Print Network [OSTI]

    Lerpiniere, A.

    2011-01-01

    The new Medieval & Renaissance Galleries employ a passive approach to environmental control. The design exploits the massive nature of the building and uses sophisticated control techniques to minimise variations in humidity in the galleries...

  2. Innovative HVAC Cycles for Severe Part Load Conditions in the Humid Climate 

    E-Print Network [OSTI]

    Pate, M. E.; Todd, T. R.

    1987-01-01

    were found in many of the buildings. Face & bypass control is suggested as one of the best methods of achieving passive humidity control under common difficult part load conditions. However, some conditions cannot be handled without additional measures...

  3. Applications of Commercial Heat Pump Water Heaters in Hot, Humid Climates 

    E-Print Network [OSTI]

    Johnson, K. F.; Shedd, A. C.

    1992-01-01

    Heat pump water heaters can provide high-efficiency water heating and supplemental space cooling and dehumidification in commercial buildings throughout the United States. They are particularly attractive in hot, humid areas where cooling loads...

  4. Applying the Leap Experience to Monitoring of Commercial Buildings in Hot and Humid Climates 

    E-Print Network [OSTI]

    Mazzucchi, R. P.; Stoops, J. L.

    1988-01-01

    , hardware installation, and quality assurance should be addressed before monitoring is attempted. This presentation describes our experience with these challenges and offers advice for those considering the monitoring of buildings in hot and humid climates...

  5. Better Unitary Equipment Air-Handlers for Efficiency and Humidity Control 

    E-Print Network [OSTI]

    Sachs, H. M.

    2002-01-01

    procedure gives too little credit for advanced air handlers that reduce air conditioning load and facilitate adaptive humidity control through automatic fan speed adjustment. DC permanent magnet variable speed motors have much lower market share than less...

  6. Relative humidity and its effect on aerosol optical depth in the vicinity of convective clouds

    E-Print Network [OSTI]

    Altaratz, O

    The hygroscopic growth of aerosols is controlled by the relative humidity (RH) and changes the aerosols' physical and hence optical properties. Observational studies of aerosol–cloud interactions evaluate the aerosol ...

  7. Sensors and Actuators B 114 (2006) 254262 Compliant and low-cost humidity nanosensors using

    E-Print Network [OSTI]

    Lin, Qiao

    2006-01-01

    of nanoporous polymer membranes such as polycarbonate, cellulose acetate, and nylon membranes. The nanosensor. On the other hand, capacitive humidity sensors are based on non-conducting materials, which make up

  8. High Temperature/Low Humidity Polymer Electrolytes Derived from Ionic Liquids

    Broader source: Energy.gov [DOE]

    Presentation on High Temperature/Low Humidity Polymer Electrolytes Derived from Ionic Liquids to the High Temperature Membrane Working Group Meeting held in Arlington, Virginia, May 26,2005.

  9. Development of a High-Performance Office Building Simulation Model for a Hot and Humid Climate 

    E-Print Network [OSTI]

    Cho, S.; Haberl, J.

    2009-01-01

    applicable to office buildings in hot and humid climates and to develop a high-performance (maximum energy-efficient) building model that only uses technologies readily available in the contemporary market. The high-performance model showed 48% total... HIGH-PERFORMANCE OFFICE BUILDING SIMULATION MODEL FOR A HOT AND HUMID CLIMATE Soolyeon Cho1 and Jeff S. Haberl2 1The Catholic University of America, Washington, D.C., USA 2Texas A&M University, College Station, TX, USA ABSTRACT...

  10. Victoria & Albert Museum- Medieval & Renaissance Galleries: A Passive Approach to Humidity Control 

    E-Print Network [OSTI]

    Lerpiniere, A.; Bingham, M.; Walker, S.

    2010-01-01

    , Kuwait, October 26-28, 2010 Table 1. Exhibition categories B C D E Collections Sensitive to high humidity (>55%) Collections Sensitive to low humidity (10... with gallery control. Figure 1. Target conditions ESL-IC-10-10-89 Proceedings of the Tenth International Conference Enhanced Building Operations, Kuwait, October 26-28, 2010 CONTROL STRATEGY The internal environment of the galleries is subject to many...

  11. Integrated and Optimized Energy-Efficient Construction Package for a Community of Production Homes in the Mixed-Humid Climate

    SciTech Connect (OSTI)

    Mallay, D.; Wiehagen, J.; Del Bianco, M.

    2014-10-01

    This research high performance home analyzes how a set of advanced technologies can be integrated into a durable and energy-efficient house in the mixed-humid climate while remaining affordable to homeowners. The technical solutions documented in this report are the cornerstone of the builder's entire business model based on delivering high-performance homes on a production basis as a standard product offering to all price segments of the residential market. Home Innovation Research Labs partnered with production builder Nexus EnergyHomes (CZ 4) and they plan to adopt the successful components of the energy solution package for all 55 homes in the community. The research objective was to optimize the builder's energy solution package based on energy performance and construction costs. All of the major construction features, including envelope upgrades, space conditioning system, hot water system, and solar electric system were analyzed.

  12. Tank characterization reference guide

    SciTech Connect (OSTI)

    De Lorenzo, D.S.; DiCenso, A.T.; Hiller, D.B.; Johnson, K.W.; Rutherford, J.H.; Smith, D.J. [Los Alamos Technical Associates, Kennewick, WA (United States); Simpson, B.C. [Westinghouse Hanford Co., Richland, WA (United States)

    1994-09-01

    Characterization of the Hanford Site high-level waste storage tanks supports safety issue resolution; operations and maintenance requirements; and retrieval, pretreatment, vitrification, and disposal technology development. Technical, historical, and programmatic information about the waste tanks is often scattered among many sources, if it is documented at all. This Tank Characterization Reference Guide, therefore, serves as a common location for much of the generic tank information that is otherwise contained in many documents. The report is intended to be an introduction to the issues and history surrounding the generation, storage, and management of the liquid process wastes, and a presentation of the sampling, analysis, and modeling activities that support the current waste characterization. This report should provide a basis upon which those unfamiliar with the Hanford Site tank farms can start their research.

  13. Nuclear Science References Database

    E-Print Network [OSTI]

    B. Pritychenko; E. B?ták; B. Singh; J. Totans

    2014-07-08

    The Nuclear Science References (NSR) database together with its associated Web interface, is the world's only comprehensive source of easily accessible low- and intermediate-energy nuclear physics bibliographic information for more than 210,000 articles since the beginning of nuclear science. The weekly-updated NSR database provides essential support for nuclear data evaluation, compilation and research activities. The principles of the database and Web application development and maintenance are described. Examples of nuclear structure, reaction and decay applications are specifically included. The complete NSR database is freely available at the websites of the National Nuclear Data Center http://www.nndc.bnl.gov/nsr and the International Atomic Energy Agency http://www-nds.iaea.org/nsr.

  14. Terms of Reference Information Security Group

    E-Print Network [OSTI]

    Haase, Markus

    Terms of Reference Information Security Group Version 3.1 8 March 2011 © University of Leeds 2011 Security Group Information Security Management 3.1 (8/3/11) Page 2 of 4 Document Control Owner: Kevin Darley, IT Security Co-ordinator, Information Systems Services, University of Leeds Source Location: V

  15. Office of Classroom Management A quick reference

    E-Print Network [OSTI]

    Thomas, David D.

    Office of Classroom Management A quick reference for how to navigate your classroom's technology of the camera. #12;Office of Classroom Management 1. Press any button other than the "system off" button 2. When and resources www.classroom.umn.edu Classroom Support Hotline: 612-625-1086 ·Controlsforthe

  16. LIBRARY AND INFORMATION SERVICES DIVISION Current References

    E-Print Network [OSTI]

    . Satellne. Data. and InformationService National Oceanographic Data Center #12;· GLOBAL CLIMATE CHANGELIBRARY AND INFORMATION SERVICES DIVISION Current References (90 -1) Global Climate Change FEBRUARY of data centers on which an information system must be built. This bibliography offers a selection

  17. MATLAB Toolbox Quick Reference

    E-Print Network [OSTI]

    Sekerinski, Emil

    Bilinear transformation method for analog-to-digital filter conversion. impinvar Impulse invariance method for analog-to-digital filter conversion. Linear System Transformations latc2tf Convert lattice filter the frequency response of digital filters. freqzplot Plot frequency response data. grpdelay Compute the average

  18. FAQS Reference Guide – Construction Management

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the March 2004 edition of DOE-STD-1180-2004, Construction Management Functional Area Qualification Standard.

  19. FAQS Reference Guide – Industrial Hygiene

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the November 2007 edition of DOE-STD-1138-2007, Industrial Hygiene Functional Area Qualification Standard.

  20. FAQS Reference Guide – Emergency Management

    Office of Energy Efficiency and Renewable Energy (EERE)

    This reference guide addresses the competency statements in the January 2004 edition of DOE-STD-1177-2004, Emergency Management Functional Area Qualification Standard.

  1. FAQS Reference Guide- Chemical Processing

    Office of Energy Efficiency and Renewable Energy (EERE)

    This reference guide addresses the competency statements in the February 2010 edition of DOE-STD-1176-2010, Chemical Processing Functional Area Qualification Standard.

  2. FAQS Reference Guide – Environmental Compliance

    Office of Energy Efficiency and Renewable Energy (EERE)

    This reference guide addresses the competency statements in the June 2011 edition of DOE-STD-1156-2011, Environmental Compliance Functional Area Qualification Standard.

  3. Ris Energy Report 5 References References for Chapter 3

    E-Print Network [OSTI]

    Risø Energy Report 5 References References for Chapter 3 1. UNEP. (2006). Background paper for the ministerial-level consultations on energy and environment for development. Ninth special session energy outlook 2005. Paris: IEA. 3. IEA. (2003). World energy investment outlook. Paris: IEA. 4. World

  4. Ris Energy Report 6 References Reference list for Chapter 3

    E-Print Network [OSTI]

    Risø Energy Report 6 References Reference list for Chapter 3 1. European Commission. (2007). Communication from the Commis- sion to the European Council and the European Parliament ­ An energy policy of the Brussels European Council 8/9 March 2007. Brussels. (7224/1/07 Rev. 1). 3. Danish Energy authority. (2007

  5. Sensor Characteristics Reference Guide

    SciTech Connect (OSTI)

    none,

    2013-04-01

    The purpose of the guide is to inform building owners and operators of the current status, capabilities, and limitations of sensor technologies. It is hoped that this guide will aid in the design and procurement process and result in successful implementation of building sensor and control systems. DOE will also use this guide to identify research priorities, develop future specifications for potential market adoption, and provide market clarity through unbiased information.

  6. Museum Archive Dehumidification in Hot and Humid Climates 

    E-Print Network [OSTI]

    Browning, B. K.

    2004-01-01

    . Portable mechanical dehumidifiers were used for roughly six years until a retrofit project brought this to management's attention. Investigations revealed that the dehumidification system design and installation were causing water to condense...

  7. Evaluation of Energy Efficiency Measures in Hot and Humid Climates 

    E-Print Network [OSTI]

    Zhao, Y.; Erwine, B.; Leonard, P.; Pease, B.; Dole, A.; Lee, A.

    2010-01-01

    . These are usually remedied with conventional mechanical air conditioning systems, but the move toward sustainability urges designers to find less energy intensive solutions. An integrated design process coupled with energy modeling and lifecycle analysis can unite...

  8. Analysis of Energy, Environmental and Life Cycle Cost Reduction Potential of Ground Source Heat Pump (GSHP) in Hot and Humid Climate

    SciTech Connect (OSTI)

    Yong X. Tao; Yimin Zhu

    2012-04-26

    It has been widely recognized that the energy saving benefits of GSHP systems are best realized in the northern and central regions where heating needs are dominant or both heating and cooling loads are comparable. For hot and humid climate such as in the states of FL, LA, TX, southern AL, MS, GA, NC and SC, buildings have much larger cooling needs than heating needs. The Hybrid GSHP (HGSHP) systems therefore have been developed and installed in some locations of those states, which use additional heat sinks (such as cooling tower, domestic water heating systems) to reject excess heat. Despite the development of HGSHP the comprehensive analysis of their benefits and barriers for wide application has been limited and often yields non-conclusive results. In general, GSHP/HGSHP systems often have higher initial costs than conventional systems making short-term economics unattractive. Addressing these technical and financial barriers call for additional evaluation of innovative utility programs, incentives and delivery approaches. From scientific and technical point of view, the potential for wide applications of GSHP especially HGSHP in hot and humid climate is significant, especially towards building zero energy homes where the combined energy efficient GSHP and abundant solar energy production in hot climate can be an optimal solution. To address these challenges, this report presents gathering and analyzing data on the costs and benefits of GSHP/HGSHP systems utilized in southern states using a representative sample of building applications. The report outlines the detailed analysis to conclude that the application of GSHP in Florida (and hot and humid climate in general) shows a good potential.

  9. Archived Reference Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  10. Archived Reference Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  11. Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

    SciTech Connect (OSTI)

    Munk, Jeffrey D [ORNL; Gehl, Anthony C [ORNL; Jackson, Roderick K [ORNL

    2012-04-01

    Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate t

  12. The Temperature and Relative Humidity Control in Cushing Library 

    E-Print Network [OSTI]

    Liu, C.; Deng, S.; Claridge, D. E.; Turner, W. D.; Bruner, H., Jr.

    2002-01-01

    the building. This paper will concentrate the unit, which serves the book stacks. This AHU is a multiple zone, constant air volume (MZCAV) system, with reheat and direct digital control (DDC). It has a standard cooling coil, glycol cooling coil, steam...

  13. APPENDIX A : SYSTEM WALKTHROUGH REFERENCE MATERIAL S

    E-Print Network [OSTI]

    WITH PRODUCTION OF 20,000 IRON AND "METAL WOOD" CLUBS A MONTH . THE MONTHLY OUTPUT WILL BE LATER RAISED TO 50 75 PCT B Y BRIDGESTONE SPORTS, 15 PCT BY UNION PRECISION CASTING CO . OF TAIWAN AND THE REMAINDER BEEN ENTRUSTING PRODUCTION OF GOLF CLUB PARTS WITH UNION PRECISION CASTING AND OTHER TAIWAN COMPANIES

  14. Sandia Energy - Technical Reference for Hydrogen Compatibility...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Technical Reference for Hydrogen Compatibility of Materials Home Transportation Energy Hydrogen Materials & Components Compatibility Technical Reference for Hydrogen Compatibility...

  15. The effect of temperature and humidity on respirator fit 

    E-Print Network [OSTI]

    Niekerk, Gary

    1986-01-01

    benefits of the cilia and mucus are lost. Other defense mechanisms of the upper respiratory tract include sneezing and coughing, which tend to minimize the amount of irritants entering the system. ~ ~ Defense mechanisms of the alveolar sacs include a... cannot detect the presence of irritant smoke a satisfactory fit is assumed. If the test subject involuntarily reacts to the irritant by coughing or sneezing, then the subject has failed the test. When isoamyl acetate is used as the testing agent...

  16. Energy Efficient Crawlspace Foundation Retrofit: Mixed Humid Climate

    SciTech Connect (OSTI)

    Del Bianco, M.; Wiehagen, J.; Wood, A.

    2013-01-01

    Residential quality management systems have most often been designed for new home construction. To address quality in existing homes in the form of Scopes of Work (SOW), the NAHB Research Center began with a new construction scope of work and applied it to an existing home project. This document is intended to outline the steps of translating a new home construction SOW to SOW for retrofit.

  17. Water adsorption on lubricated a-CHx in humid environments Nisha Shuklaa,, Erik Svedberga

    E-Print Network [OSTI]

    Gellman, Andrew J.

    Water adsorption on lubricated a-CHx in humid environments Nisha Shuklaa,Ã, Erik Svedberga , Rene lubricant. The lubricants used included Fomblin Z-03, Z-disoc, and Z-tetraol deposited on the surfaces of a independent of a-CHx film thickness. The presence of the lubricant reduces the amount of adsorbed water

  18. Matrix penetration in the bulk:In uence of humidity: Morphological analysis of wood welding

    E-Print Network [OSTI]

    Psaltis, Demetri

    Matrix penetration in the bulk:In uence of humidity: Morphological analysis of wood welding.pichelin@b .ch Context: Wood can be welded using linear vibration welding tech- niques similar to the ones in plastic and metal industry[1] . Wood welding allows bonding strength similar to glued joints. However, due

  19. A NOTE ON SURFACE HUMIDITY MEASUREMENTS IN THE COLD CANADIAN ENVIRONMENT

    E-Print Network [OSTI]

    Dery, Stephen

    ). With a growing interest in evaluating the water and energy fluxes at high latitudes, there is a renewed demand observations taken by two different sensors at six remote Canadian Arctic locations are compared of climate autostations in Canada. Keywords: Arctic, Hygrometer, Relative Humidity, Snow, Sublimation. 1

  20. Analysis of the Energy Savings Potential in K-5 Schools in Hot and Humid Climates 

    E-Print Network [OSTI]

    Im, P.; Haberl, J.

    2008-01-01

    This paper presents the analysis of the energy savings potential in K-5 schools in hot and humid climates. For the analysis, an existing K-5 school in Central Texas was selected as a case study school, and the building energy related data...

  1. Bio-Char Soil Management on Highly Weathered Soils in the Humid Tropics

    E-Print Network [OSTI]

    Lehmann, Johannes

    36 Bio-Char Soil Management on Highly Weathered Soils in the Humid Tropics Johannes Lehmann1), ColombiaQ1 CONTENTS 36.1 Bio-Char Management and Soil Nutrient Availability ............................................. 518 36.2 Microbial Cycling of Nutrients in Soils with Bio-Char

  2. Distributed Performance of Polymer Electrolyte Fuel Cells under Low-Humidity Conditions

    E-Print Network [OSTI]

    Mench, Matthew M.

    fuel cells PEFC with low humidification. In order to more fully understand and optimize performanceDistributed Performance of Polymer Electrolyte Fuel Cells under Low-Humidity Conditions Q. Dong,a, * M. M. Mench,a, **,z S. Cleghorn,b and U. Beuscherb a Fuel Cell Dynamics and Diagnostics Laboratory

  3. Understanding the Temperature and Humidity Environment Inside a PV Module (Presentation)

    SciTech Connect (OSTI)

    Kempe, M.

    2013-06-01

    This presentation addresses moisture-driven degradation processes in PV modules and the conditions to use for accelerated stress testing. Here we show that by choosing humidity conditions that more closely match the use environment, one can minimize the uncertainty associated with moisture induced degradation modes.

  4. Monitoring groundwater storage changes in the highly1 seasonal humid tropics: validation of GRACE measurements2

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    1 Monitoring groundwater storage changes in the highly1 seasonal humid tropics: validation of GRACE the seasonality and trend in groundwater storage associated with intensive groundwater19 abstraction for dry to 2007) groundwater storage changes21 (GWS) correlate well (r=0.77 to 0.93, p-value

  5. Performance Verification of Production-Scalable Energy-Efficient Solutions: Winchester/Camberley Homes Mixed-Humid Climate

    SciTech Connect (OSTI)

    Mallay, D.; Wiehagen, J.

    2014-07-01

    Winchester/Camberley Homes with the Building America program and its NAHB Research Center Industry Partnership collaborated to develop a new set of high performance home designs that could be applicable on a production scale. The new home designs are to be constructed in the mixed humid climate zone four and could eventually apply to all of the builder's home designs to meet or exceed future energy codes or performance-based programs. However, the builder recognized that the combination of new wall framing designs and materials, higher levels of insulation in the wall cavity, and more detailed air sealing to achieve lower infiltration rates changes the moisture characteristics of the wall system. In order to ensure long term durability and repeatable successful implementation with few call-backs, this report demonstrates through measured data that the wall system functions as a dynamic system, responding to changing interior and outdoor environmental conditions within recognized limits of the materials that make up the wall system. A similar investigation was made with respect to the complete redesign of the heating, cooling, air distribution, and ventilation systems intended to optimize the equipment size and configuration to significantly improve efficiency while maintaining indoor comfort. Recognizing the need to demonstrate the benefits of these efficiency features, the builder offered a new house model to serve as a test case to develop framing designs, evaluate material selections and installation requirements, changes to work scopes and contractor learning curves, as well as to compare theoretical performance characteristics with measured results.

  6. Performance Verification of Production-Scalable Energy-Efficient Solutions: Winchester/Camberley Homes Mixed-Humid Climate

    SciTech Connect (OSTI)

    Mallay, D.; Wiehagen, J.

    2014-07-01

    Winchester/Camberley Homes collaborated with the Building America team Partnership for Home Innovation to develop a new set of high performance home designs that could be applicable on a production scale. The new home designs are to be constructed in the mixed humid climate zone and could eventually apply to all of the builder's home designs to meet or exceed future energy codes or performance-based programs. However, the builder recognized that the combination of new wall framing designs and materials, higher levels of insulation in the wall cavity, and more detailed air sealing to achieve lower infiltration rates changes the moisture characteristics of the wall system. In order to ensure long term durability and repeatable successful implementation with few call-backs, the project team demonstrated through measured data that the wall system functions as a dynamic system, responding to changing interior and outdoor environmental conditions within recognized limits of the materials that make up the wall system. A similar investigation was made with respect to the complete redesign of the HVAC systems to significantly improve efficiency while maintaining indoor comfort. Recognizing the need to demonstrate the benefits of these efficiency features, the builder offered a new house model to serve as a test case to develop framing designs, evaluate material selections and installation requirements, changes to work scopes and contractor learning curves, as well as to compare theoretical performance characteristics with measured results.

  7. RELATIVE HUMIDITY TESTS IN SUPPORT OF THE 3013 STORAGE AND SURVEILLANCE PROGRAM

    SciTech Connect (OSTI)

    Mickalonis, J.; Duffey, J.

    2011-08-01

    Techniques to control the initial relative humidity over oxide/salt mixtures have been developed using cerium oxide as a surrogate for plutonium oxide. Such control is required to validate certain assumptions in the Department of Energy Standard DOE-STD-3013, and to provide essential information to support field surveillance at the storage sites for excess plutonium oxides. Concern over the validity of the assumption that corrosion induced degradation in 3013 containers could be controlled by assuring that the moisture content of any stored oxide/salt mixture was below 0.5 w t% arose when stress corrosion cracks were found in test samples exposed at room temperature to plutonium oxide/salt mixtures having a moisture content only marginally above 0.5 wt %. Additionally, analysis of the stress corrosion cracking observations suggests that the initial relative humidity over the oxide/salt mixture may play a major role in the cracking process. The investigations summarized in this report provide the procedures necessary to control the initial relative humidity to selected values within the range of 16 to 50% by controlling the loading relative humidity (18 to 60%) and the oxide/salt mixture water content (0.05 to 0.45 wt %). The studies also demonstrated that the initial relative humidity may be estimated by calculations using software EQ3/6. Cerium oxide/salt mixtures were used in this study because qualification tests with non-radioactive materials will reduce costs while increasing the breadth of the test programs required to support field surveillances of stored 3013 containers.

  8. SAM Photovoltaic Model Technical Reference

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    SAM Photovoltaic Model Technical Reference P. Gilman National Renewable Energy Laboratory Technical Report NRELTP-6A20-64102 May 2015 NREL is a national laboratory of the U.S....

  9. FAQS Reference Guide – Occupational Safety

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in the July 2011 version of DOE-STD-1160-2011, Occupational Safety Functional Area Qualification Standard.

  10. Safeguards and Security Program References

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2005-08-26

    The manual establishes definitions for terms related to the Department of Energy Safeguards and Security (S&S) Program and includes lists of references and acronyms/abbreviations applicable to S&S Program directives. Cancels the Safeguards and Security Glossary of Terms, dated 12-18-95. Current Safeguards and Security Program References can also be found at Safeguards and Security Policy Information Resource (http://pir.pnl.gov/)

  11. Ventilated Facade Design for Hot and Humid Climates 

    E-Print Network [OSTI]

    Haase, M.; Amato, A.

    2006-01-01

    systems. The Hong Kong climate offers short warm winters which together with a high internal heat gain make heating redundant. Figure 7 illustrates the simulation results of cooling energy savings. The results show significant cooling savings of up... the results significantly. 0% 5% 10% 15% 20% 25% 30% b a s e c a s e ( i n t e r n a l s h a d i n g ) b a s e c a s e w i t h r e f l e c t i v e g l a s s b a s e c a s e s o l a r c o n t r o l g l a s s D S F 1 - 1 D S F 1 - 2 D S F 2...

  12. REFERENCES

    E-Print Network [OSTI]

    2008-08-23

    Mechanism of Fluid Displacement in Sands. Trans. Am. Inst. Min. Metall. Eng.,. 146: 107-116. Chaudhari, N.M., 1971. An Improved Numerical Technique for ...

  13. REFERENCES

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    5 United States Code (U.S.C.) Section 552a. . b. P.L. 104-106, Division E, Clinger Cohen Act (CCA) (formerly Information Technology Management Reform Act of 1996. c. P.L....

  14. Building a 40% Energy Saving House in the Mixed-Humid Climate

    SciTech Connect (OSTI)

    Christian, Jeffrey E [ORNL; Bonar, Jacob [ORNL

    2011-10-01

    This report describes a home that uses 40% less energy than the energy-efficient Building America standard - a giant step in the pursuit of affordable near-zero-energy housing through the evolution of five near-zero-energy research houses. This four-bedroom, two-bath, 1232-ft2 house has a Home Energy Rating System (HERS) index of 35 (a HERS rating of 0 is a zero-energy house, a conventional new house would have a HERS rating of 100), which qualifies it for federal energy efficiency and solar incentives. The house is leading to the planned construction of a similar home in Greensburg, Kansas, and 21 staff houses in the Walden Reserve, a 7000-unit "deep green" community in Cookville, Tennessee. Discussions are underway for construction of similar houses in Charleston, South Carolina, Seattle, Washington, Knoxville and Oak Ridge, Tennessee, and upstate New York. This house should lead to a 40% and 50% Gate-3, Mixed-Humid-Climate Joule for the DOE Building America Program. The house is constructed with structurally-insulated-panel walls and roof, raised metal-seam roof with infrared reflective coating, airtight envelope (1.65 air changes per hour at 50 Pascal), supply mechanical ventilation, ducts inside the conditioned space, extensive moisture control package, foundation geothermal space heating and cooling system, ZEHcor wall, solar water heater, and a 2.2 kWp grid-connected photovoltaic (PV) system. The detailed specifications for the envelope and the equipment used in ZEH5 compared to all the houses in this series are shown in Tables 1 and 2. Based on a validated computer simulation of ZEH5 with typical occupancy patterns and energy services for four occupants, energy for this all-electric house is predicted to cost only $0.66/day ($0.86/day counting the hookup charges). By contrast, the benchmark house would require $3.56/day, including hookup charges (these costs are based on a 2006 residential rates of $0.07/kWh and solar buyback at $0.15/kWh). The solar fraction for this home located in Lenoir City, Tennessee, is predicted to be as high as 41%(accounting for both solar PV and the solar water heater). This all-electric home is predicted to use 25 kWh/day based on the one year of measured data used to calibrate a whole-building simulation model. Based on two years of measured data, the roof-mounted 2.2 kWp PV system is predicted to generate 7.5 kWh/day. The 2005 cost to commercially construct ZEH5, including builder profit and overhead, is estimated at about $150,000. This cost - for ZEH5's panelized construction, premanufactured utility wall (ZEHcor), foundation geothermal system, and the addition of the walkout lower level, and considering the falling cost for PV - suggests that the construction cost per ft2 for a ZEH5 two-story will be even more cost-competitive. The 2005 construction cost estimate for a finished-out ZEH5 with 2632 ft2 is $222,000 or $85/ft2. The intention of this report is to help builders and homeowners make the decision to build zero-energy-ready homes. Detailed drawings, specifications, and lessons learned in the construction and analysis of data from about 100 sensors monitoring thermal performance for a one-year period are presented. This information should be specifically useful to those considering structural insulated panel walls and roof, foundation geothermal space heating and cooling, solar water heater and roof-mounted, photovoltaic, grid-tied systems.

  15. Fast Reference-Based MRI

    E-Print Network [OSTI]

    Weizman, Lior; Ben-Basaht, Dafna

    2015-01-01

    In many clinical MRI scenarios, existing imaging information can be used to significantly shorten acquisition time or to improve Signal to Noise Ratio (SNR). In some cases, a previously acquired image can serve as a reference image, that may exhibit similarity to the image being acquired. Examples include similarity between adjacent slices in high resolution MRI, similarity between various contrasts in the same scan and similarity between different scans of the same patient. In this paper we present a general framework for utilizing reference images for fast MRI. We take into account that the reference image may exhibit low similarity with the acquired image and develop an iterative weighted approach for reconstruction, which tunes the weights according to the degree of similarity. Experiments demonstrate the performance of the method in three different clinical MRI scenarios: SNR improvement in high resolution brain MRI, utilizing similarity between T2-weighted and fluid-attenuated inversion recovery (FLAIR)...

  16. Problem 7-3: The air enters with a dry-bulb temperature of 50 o F and, at 50% relative humidity, with a wet-

    E-Print Network [OSTI]

    of the power-plant Rankine cycle. The actual process evaporates enough water to increase the humidity ratio, with a wet- bulb temperature of 42 o F, according to the Psychrometric Chart (page 821). The main evaporative% relative humidity. This process would evaporate enough water to increase the humidity ratio from 0

  17. Humidity effects on tip-induced polarization switching in lithium niobate

    SciTech Connect (OSTI)

    Ievlev, A. V.; Morozovska, A. N.; Shur, V. Ya.; Kalinin, S. V.

    2014-03-03

    In the last several decades, ferroelectrics have attracted much attention as perspective materials for nonlinear optics and data storage devices. Scanning probe microscopy (SPM) has emerged as a powerful tool both for studies of domain structures with nanoscale spatial resolution and for writing the isolated nanodomains by local application of the electric field. Quantitative analysis of the observed behavior requires understanding the role of environmental factors on imaging and switching process. Here, we study the influence of the relative humidity in the SPM chamber on tip-induced polarization switching. The observed effects are attributed to existence of a water meniscus between the tip and the sample surface in humid atmosphere. These results are important for a deeper understanding of complex investigations of ferroelectric materials and their applications and suggest the necessity for fundamental studies of electrocapillary phenomena at the tip-surface junction and their interplay with bias-induced materials responses.

  18. Humidity effects on tip-induced polarization switching in lithium niobate

    SciTech Connect (OSTI)

    Ievlev, Anton; Morozovska, A. N.; Shur, Vladimir Ya.; Kalinin, Sergei V

    2014-01-01

    In the last several decades, ferroelectrics have attracted much attention as perspective materials for nonlinear optics and data storage devices. Scanning probe microscopy (SPM) has emerged as a powerful tool both for studies of domain structures with nanoscale spatial resolution and for writing the isolated nanodomains by local application of the electric field. Quantitative analysis of the observed behavior requires understanding the role of environmental factors on imaging and switching process. Here we study the influence of the relative humidity in the SPM chamber on tip-induced polarization switching. The observed effects are attributed to existence of a water meniscus between the tip and the sample surface in humid atmosphere. These results are important for a deeper understanding of complex investigations of ferroelectric materials and their applications, and suggest the necessity for fundamental studies of electrocapillary phenomena at the tip-surface junction and their interplay with bias-induced materials responses.

  19. Fischer-Tropsch synthesis from a low H/sub 2/:CO gas in a dry fluidized-bed system. Volume 2. Development of microreactor systems for unsteady-state Fischer-Tropsch synthesis. Final technical report. [408 references

    SciTech Connect (OSTI)

    Whiting, G.K.; Liu, Y.A.; Squires, A.M.

    1986-10-01

    Vibrofluidized microreactor systems have been developed for studies of unsteady-state Fischer-Tropsch synthesis. This development is aimed at preventing carbon deposition on a fused-iron catalyst in a novel reactor called the ''heat tray.'' This reactor involves a supernatant gas flowing over a shallow fluidized bed of catalyst particles. Three systems were built: (1) a vibrofluidized-bed microreactor system for obtaining baseline carbon deposition information under industrially important reaction conditions; (2) a sliding-plug vibrofluidized-bed microreactor system for rapid switching of feed gases in the F-T synthesis; and (3) a cold-flow microreactor model for studying the gas mixing characteristics of the sliding-plug vibrofluidized-bed microreactor. The results show that catalyst defluidization occurred under steady-state synthesis conditions below 395 C using a feed gas of H/sub 2//CO ratio of 2:1 or less. Above 395 C, the probability of hydrocarbon chain growth (..cap alpha.. < 0.50 to prevent accumulation of high-molecular-weight species that cause defluidization. Carbon deposition was rapid above 395 C when a feed gas of H/sub 2//CO ratio of 2:1 or less was used. Cold-flow microreactor model studies show that rapid (on the order of seconds), quantitative switching of feed gases over a vibrofluidized bed of catalyst could be achieved. Vibrofluidization of the catalyst bed induced little backmixing of feed gas over the investigated flow-rate range of 417 to 1650 actual mm/sup 3//s. Further, cold-flow microreactor model studies showed intense solid mixing when a bed of fused-iron catalyst (150 to 300 microns) was vibrofluidized at 24 cycles per second with a peak-to-peak amplitude of 4 mm. The development of the microreactor systems provided an easy way of accurately determining integral fluid-bed kinetics in a laboratory reactor. 408 refs., 156 figs., 27 tabs.

  20. 40% Whole-House Energy Savings in the Hot-Humid Climate

    SciTech Connect (OSTI)

    none,

    2011-09-01

    This guide book is a resource to help builders design and construct highly energy-efficient homes, while addressing building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the hot-humid climate can build homes that achieve whole house energy savings of 40% over the Building America benchmark (the 1993 Model Energy Code) with no added overall costs for consumers.

  1. 40% Whole-House Energy Savings in the Mixed-Humid Climate

    SciTech Connect (OSTI)

    Baechler, Michael C.; Gilbride, T. L.; Hefty, M. G.; Cole, P. C.; Adams, K.; Butner, R. S.; Ortiz, S. J.; Love, Pat M.

    2011-09-01

    This guide book is a resource to help builders design and construct highly energy-efficient homes, while addressing building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the mixed-humid climate can build homes that achieve whole house energy savings of 40% over the Building America benchmark (the 1993 Model Energy Code) with no added overall costs for consumers.

  2. The effect of temperature and relative humidity levels upon charcoal tube sampling for vinyl choloride 

    E-Print Network [OSTI]

    McCaskill, Gerald Daniel

    1983-01-01

    hygienist involves sorbent tubes. '~(hen correctly applied, samples collected in this manner yield time- weighted average values for airborne concentrations to which the individual of interest is exposed. To correctly use the results of this sampling.... This is a significant finding due to the fact that as the ambient air tem- perature rises, so does its capability to hoId water vapor. At 90! relative humidity, the amount of water vapor in the air virtually doubles when the ambient air temperature...

  3. IEC Quality Assurance Task Group 5: UV, Temperature, and Humidity (Presentation)

    SciTech Connect (OSTI)

    Miller, D.; Bath, J.; Kohl, M.; Shioda, T.

    2014-03-01

    Taskgroup 5 (TG5) is concerned with a comparative aging standard incorporating factors including ultraviolet radiation, temperature, and humidity. Separate experiments are being conducted in support of a test standard via the regional sub-groups in Asia, Europe, and the United States. The authors will describe the objectives and timeline for TG5 as well as providing an update on the experiments in progress.

  4. Title: Information theory Reference: 13791

    E-Print Network [OSTI]

    Overill, Richard E.

    environment or communicates with others. One of the fundamental tenets of information theory a spate of publications appeared applying information theory to many aspects of music analysisTitle: Information theory Reference: 13791 Sort key: informationtheory Version: 3.0 Revision

  5. / R Reference May 25, 2010

    E-Print Network [OSTI]

    Loon, E. Emiel van

    of time searching for a simple way to do what I wanted, but at the end of the semester, I was pleasantly that the entire resulting derived work is distributed under the terms of a permission notice identical to this one, Matlab / R Reference 2 Contents 1 Help 3 2 Entering/building/indexing matrices 3 2.1 Cell arrays

  6. Reference Workbook: Pollution Prevention Plans

    E-Print Network [OSTI]

    #12;Reference Workbook: Pollution Prevention Plans DOE FRAP 1994-35 Prepared for: I Environment Canada Environmental Protection Fraser Pollution Abatement Office 224 West Esplanade North Vancouver, B Pollution Abatement Office. Environment Canada is not responsible for the content of this report but has

  7. EMERGENCY PROCEDURES QUICK REFERENCE GUIDE

    E-Print Network [OSTI]

    Frantz, Kyle J.

    1 EMERGENCY PROCEDURES QUICK REFERENCE GUIDE GSU EMERGENCY MANAGEMENT 404-413-0783 GSU POLICE: 404-413-3333 ATLANTA FIRE RESUCE: 911 #12;2 Emergency Response - Order of Priority In any emergency situation, Georgia infrastructure and facilities 3. Resume our research and educational programs Emergency Action Levels: A. Level 1

  8. Technology Solutions Case Study: Improving Comfort in Hot-Humid Climates with a Whole-House Dehumidifier

    SciTech Connect (OSTI)

    2013-11-01

    In order to quantify the performance of a combined whole-house dehumidifier (WHD) AC system, researchers from the Consortium of Advanced Residential Buildings (CARB) team monitored the operation of two Lennox AC systems coupled with a Honeywell DH150 TrueDRY whole-house dehumidifier for a six-month period. By using a WHD to control moisture levels (latent cooling) and optimizing a central AC to control temperature (sensible cooling), improvements in comfort can be achieved while reducing utility costs. Indoor comfort for this study was defined as maintaining indoor conditions at below 60% RH and a humidity ratio of 0.012 lbm/lbm while at common dry bulb set point temperatures of 74°-80°F. In addition to enhanced comfort, controlling moisture to these levels can reduce the risk of other potential issues such as mold growth, pests, and building component degradation. Because a standard AC must also reduce dry bulb air temperature in order to remove moisture, a WHD is typically needed to support these latent loads when sensible heat removal is not desired.

  9. WECC Variable Generation Planning Reference Book

    SciTech Connect (OSTI)

    Makarov, Yuri V.; Du, Pengwei; Etingov, Pavel V.; Ma, Jian; Vyakaranam, Bharat

    2013-05-14

    This planning reference book is a document reflecting a Western Electricity Coordination Council (WECC) effort to put together multiple sources of information and provide a clear, systemic, comprehensive outline of the problems, both existing and anticipated; their impacts on the system; currently used and proposed solutions by the industry and research community; planning practices; new technologies, equipment, and standards; and expected future trends. This living (periodically updated) document could help WECC and other practicing engineers, especially the younger generation of engineers joining the workforce, to get familiar with a large variety of information related to the integration of variable resources into the WECC system, bypassing in part the need for time-consuming information gathering and learning processes from more experienced engineers or from the literature.

  10. Factors contributing to the degradation of poly(p-phenylene benzobisoxazole) (PBO) fibers under elevated temperature and humidity conditions 

    E-Print Network [OSTI]

    O'Neil, Joseph M

    2006-10-30

    The moisture absorption behavior of Zylon fibers was characterized in various high temperature and high humidity conditions in a controlled environment. The results of these thermal cycling tests show that PBO fibers not ...

  11. An Experimental Evaluation of Duct-Mounted Relative Humidity Sensors: Part 3 – Repeatability, Hysteresis and Linearity Results 

    E-Print Network [OSTI]

    Joshi, S.N.; Pate, M.B.; Nelson, R.M.; House, J.H.; Klaassen, C.J.

    2005-01-01

    Reproduced with permission of the copyright owner. Further reproduction prohibited without permission. An Experimental Evaluation of Duct-Mounted Relative Humidity Sensors: Part 3-Repeatability, Hyste... Joshi, Shailesh N;House, John M...

  12. The use of a distributed hydrologic model to predict dynamic landslide susceptibility for a humid basin in Puerto Rico

    E-Print Network [OSTI]

    Kamal, Sameer A. (Sameer Ahmed)

    2009-01-01

    This thesis describes the use of a distributed hydrology model in conjunction with a Factor of Safety (FS) algorithm to predict dynamic landslide susceptibility for a humid basin in Puerto Rico. The Mameyes basin, located ...

  13. The Determination of the Water Vapor Content in the Pulkovo VKM-100 Multipass Vacuum Cell Using Polymer Sensors of Humidity

    E-Print Network [OSTI]

    Galkin, V D; Nikanorova, I N; Sal'nikov, I B; Leiterer, U; Alekseeva, G A; Novikov, V V; Dauß, D

    2010-01-01

    In spectral studies of water vapor under laboratory conditions (determination of molecular constants, measurement for spectral transmission functions), the amount of water vapor in the time of the measurements is one of the most essential parameters, which should be determined accurately. We discuss the application for this purpose of polymer sensors of humidity manufactured by Praktik-NC (Moscow) and used in the Pulkovo VKM-100 multipass vacuum cell. These sensors were examined in the laboratory of Lindenberg Meteorological observatory (Germany) by comparison between their readings and those of standard measuring devices for various values of relative humidity, pressure, and temperature. We also carried out measurements of relative humidity in boxes with saline solution, in which the relative humidity that corresponds to a given solution is guaranteed with the accuracy of several tenths of percent. The analysis of the results of the laboratory examination of the sensors and extended sets of measurements made...

  14. Link between land-ocean warming contrast and surface relative humidities in simulations with coupled climate models

    E-Print Network [OSTI]

    Byrne, Michael Patrick

    Simulations of warming climates with coupled climate models exhibit strong land-ocean contrasts in changes in surface temperature and relative humidity, but little land-ocean contrast in changes in equivalent potential ...

  15. Simulation of Dehumidification Characteristics of High Efficiency Residential Central Air-Conditioners in Hot and Humid Climates 

    E-Print Network [OSTI]

    Katipamula, S.; O'Neal, D.; Somasundram, S.

    1988-01-01

    This study assesses the dehumidifying performance of the high efficiency residential central air conditioners (CAC) in hot/humid climates typified by that of Houston and Galveston. The performance study is based on such factors as: (i) weather (ii...

  16. National Weatherization Assistance Program Impact Evaluation: Impact of Exhaust-Only Ventilation on Radon and Indoor Humidity - A Field Investigation

    SciTech Connect (OSTI)

    Pigg, Scott

    2014-09-01

    The study described here sought to assess the impact of exhaust-only ventilation on indoor radon and humidity in single-family homes that had been treated by the Weatherization Assistance Program (WAP).

  17. Measured Cooling Season Results Relating the Impact of Mechanical Ventilation on Energy, Comfort, and Indoor Air Quality in Humid Climates

    SciTech Connect (OSTI)

    Martin, Eric; Amos, Bryan; McIlvaine, Janet; Chasar, David; Widder, Sarah H.; Fonorow, Ken

    2014-08-22

    Conference Paper for ACEEE Summer Study in Buildings discussing results to date of a project evaluating the impact of ventialtion on energy use, comfort, durability, and cost in the hot humid climate.

  18. Thermal Comfort Study in a Naturally Ventilated Residential Building in a Tropical Hot-Humid Climate Region 

    E-Print Network [OSTI]

    Soebarto, V. I.; Handjarinto, S.

    1998-01-01

    This paper presents a thermal comfort study in a naturally ventilated residential building located in a tropical hot-humid climate region. The specific objective of this study is to investigate whether thermal comfort in this house can be achieved...

  19. Winchester/Camberley Homes New Construction Test House Design, Construction, and Short-Term Testing in a Mixed-Humid Climate

    SciTech Connect (OSTI)

    Mallav, D.; Wiehagen, J.; Wood, A.

    2012-10-01

    The NAHB Research Center partnered with production builder Winchester/Camberley Homes to build a DOE Building America New Construction Test House (NCTH). This single family, detached house, located in the mixed-humid climate zone of Silver Spring, MD, was completed in June 2011. The primary goal for this house was to improve energy efficiency by 30% over the Building America B10 benchmark by developing and implementing an optimized energy solutions package design that could be cost effectively and reliably constructed on a production basis using quality management practices. The intent of this report is to outline the features of this house, discuss the implementation of the energy efficient design, and report on short-term testing results. During the interactive design process of this project, numerous iterations of the framing, air sealing, insulation, and space conditioning systems were evaluated for energy performance, cost, and practical implementation. The final design featured numerous advanced framing techniques, high levels of insulation, and the HVAC system entirely within conditioned space. Short-term testing confirmed a very tight thermal envelope and efficient and effective heating and cooling. In addition, relevant heating, cooling, humidity, energy, and wall cavity moisture data will be collected and presented in a future long-term report.

  20. The proper characteristics of frame reference as a 4-invariants

    E-Print Network [OSTI]

    V. V. Voytik

    2015-06-02

    The paper derived 4-dimensional equation for the proper characteristics of the rigid frame of reference. From these conditions it follows the laws of motion of its proper tetrad and inverse kinematics equation, i. e., differential equations, which solves the problem of recovering the parameters of the motion of rigid frame of reference for their proper acceleration and angular velocity. In particular it is shown that the commission boost the moving frame of reference having Thomas precession for a new laboratory system will have a combination of two rotations: a new self-Thomas precession and rotation Wigner, which combine to give an initial frequency of the Thomas precession.

  1. 7. Flows in a rotating reference frame 7.1. Rotating reference frames

    E-Print Network [OSTI]

    Read, Peter L.

    in a rotating reference frame. We use rotating axes, fixed w.r.t. the rotating system but note that time-derivatives of vectors must be modified: 1 #12;Suppose frame R rotates at constant angular velocity = (0, 0, ) w.r.t. an inertial frame I. Consider vector A(t) ­ suppose for simplicity that it lies in the xy-plane of R and I

  2. Humidity scanning quartz crystal microbalance with dissipation monitoring setup for determination of sorption-desorption isotherms and rheological changes

    SciTech Connect (OSTI)

    Björklund, Sebastian Kocherbitov, Vitaly

    2015-05-15

    A new method to determine water sorption-desorption isotherms with high resolution in the complete range of water activities (relative humidities) is presented. The method is based on quartz crystal microbalance with dissipation monitoring (QCM-D). The QCM-D is equipped with a humidity module in which the sample film is kept in air with controlled humidity. The experimental setup allows for continuous scanning of the relative humidity from either dry to humid conditions or vice versa. The amount of water sorbed or desorbed from the sample is determined from the resonance frequencies of the coated quartz sensor, via analysis of the overtone dependence. In addition, the method allows for characterization of hydration induced changes of the rheological properties from the dissipation data, which is closely connected to the viscoelasticity of the film. The accuracy of the humidity scanning setup is confirmed in control experiments. Sorption-desorption isotherms of pig gastric mucin and lysozyme, obtained by the new method, show good agreement with previous results. Finally, we show that the deposition technique used to coat the quartz sensor influences the QCM-D data and how this issue can be used to obtain further information on the effect of hydration. In particular, we demonstrate that spin-coating represents an attractive alternative to obtain sorption-desorption isotherms, while drop-coating provides additional information on changes of the rheological properties during hydration.

  3. Emergency Responder Radioactive Material Quick Reference Sheet

    Broader source: Energy.gov [DOE]

    Transportation Emergency Preparedness Program (TEPP) Emergency Responder Radioactive Material Quick Reference Sheet

  4. Generic Argillite/Shale Disposal Reference Case

    E-Print Network [OSTI]

    Zheng, Liange

    2014-01-01

    Shale Disposal Reference Case August 2014 Borehole activity: Oil and gas drilling targets for hydrocarbon resource

  5. Start-Up of Air Conditioning Systems After Periods of Shutdown (Humidity Considerations) 

    E-Print Network [OSTI]

    Todd, T. R.

    1986-01-01

    . Unfortunately the latent load required to bring the space back to comfort conditions is usually much higher than the sensible load. Most methods of control are ill suited for this duty. This paper examines the response of various types of air conditioning...

  6. Thermal and lighting performance of toplighting systems in the hot and humid climate of Thailand 

    E-Print Network [OSTI]

    Harntaweewongsa, Siritip

    2006-10-30

    3.10 Scale model materials and reflectance values................................................ 45 5.1 Horizontal exterior illuminance (HEI) level generated from RADIANCE .. 99 5.2 Single unit prototype: illuminance gradient comparison................................................................ 5 1.4.2. Delimitations ............................................................ 5 1.5. Organization of the Thesis ................................................... 6 II REVIEW OF THE LITERATURE...

  7. Direct-Expansion Air-Conditioning System Performance in Low Humidity Applications: A Case Study 

    E-Print Network [OSTI]

    Khattar, M. K.; Keebaugh, D.

    1987-01-01

    . Historic energy-use data and field-measured performance data are analyzed. The importance of certain design and operating parameters such as indoor airflow quantity, cooling coil apparatus dew-point temperature and the air-handling unit's fan operating...

  8. Control Humidity With Single-Duct, Single-Zone, Constant Air Volume System 

    E-Print Network [OSTI]

    Chen, H.; Deng, S.; Bruner, H. L.; Claridge, D. E.

    2000-01-01

    The lecture hall of the Richardson Petroleum Building at Texas A&M University is a large lecture hall, with a total floor area of approximately 2500 ft^2. The lecture hall was served by a constant air volume (CAV) air handling unit (AHU) which had...

  9. Reference Inflow Characterization for River Resource Reference Model (RM2)

    SciTech Connect (OSTI)

    Neary, Vincent S [ORNL

    2011-12-01

    Sandia National Laboratory (SNL) is leading an effort to develop reference models for marine and hydrokinetic technologies and wave and current energy resources. This effort will allow the refinement of technology design tools, accurate estimates of a baseline levelized cost of energy (LCoE), and the identification of the main cost drivers that need to be addressed to achieve a competitive LCoE. As part of this effort, Oak Ridge National Laboratory was charged with examining and reporting reference river inflow characteristics for reference model 2 (RM2). Published turbulent flow data from large rivers, a water supply canal and laboratory flumes, are reviewed to determine the range of velocities, turbulence intensities and turbulent stresses acting on hydrokinetic technologies, and also to evaluate the validity of classical models that describe the depth variation of the time-mean velocity and turbulent normal Reynolds stresses. The classical models are found to generally perform well in describing river inflow characteristics. A potential challenge in river inflow characterization, however, is the high variability of depth and flow over the design life of a hydrokinetic device. This variation can have significant effects on the inflow mean velocity and turbulence intensity experienced by stationary and bottom mounted hydrokinetic energy conversion devices, which requires further investigation, but are expected to have minimal effects on surface mounted devices like the vertical axis turbine device designed for RM2. A simple methodology for obtaining an approximate inflow characterization for surface deployed devices is developed using the relation umax=(7/6)V where V is the bulk velocity and umax is assumed to be the near-surface velocity. The application of this expression is recommended for deriving the local inflow velocity acting on the energy extraction planes of the RM2 vertical axis rotors, where V=Q/A can be calculated given a USGS gage flow time-series and stage vs. cross-section area rating relationship.

  10. A Configurable Reference Modelling Language1 M. Rosemanna

    E-Print Network [OSTI]

    van der Aalst, Wil

    , Configuration, Event-driven Process Chains 1 This research project is financially supported by SAP Corporate reference models "just" depict the possible system capabilities and cannot sufficiently guide the project, Eindhoven, The Netherlands, w.m.p.v.d.aalst@tm.tue.nl Abstract Enterprise Systems (ES) are comprehensive off

  11. 20th Century Reanalysis Project Ensemble Gateway: 56 Estimates of World Temperature, Pressure, Humidity, and Wind, 1871-2010

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    This site provides data from the 20th Century Reanalysis Project, offering temperature, pressure, humidity, and wind predictions in 200 km sections all around the earth from 1871 to 2010, every 6 hours, based on historical data. The ensemble mean and standard deviation for each value were calculated over a set of 56 simulations. Data for each of the 56 ensemble members are included here. The dataset consists of files in netCDF 4 format that are available for download from the National Energy Research. The goal of the 20th Century Reanalysis Project is to use a Kalman filter-based technique to produce a global trophospheric circulation dataset at four-times-daily resolution back to 1871. The only dataset available for the early 20th century consists of error-ridden hand-drawn analyses of the mean sea level pressure field over the Northern Hemisphere. Modern data assimilation systems have the potential to improve upon these maps, but prior to 1948, few digitized upper-air sounding observations are available for such a reanalysis. The global tropospheric circulation dataset will provide an important validation check on the climate models used to make 21st century climate projections....[copied from http://portal.nersc.gov/project/20C_Reanalysis/

  12. SRNL PHASE II SHELF LIFE STUDIES - SERIES 1 ROOM TEMPERATURE AND HIGH RELATIVE HUMIDITY

    SciTech Connect (OSTI)

    Mickalonis, J.; Duffey, J.

    2012-09-12

    The Savannah River National Laboratory (SRNL) Phase II, Series 1 shelf-life corrosion testing for the Department of Energy Standard 3013 container is presented and discussed in terms of the localized corrosion behavior of Type 304 stainless steel in contact with moist plutonium oxide and chloride salt mixtures and the potential impact to the 3013 inner container. This testing was designed to address the influence of temperature, salt composition, initial salt moisture, residual stress and type of oxide/salt contact on the relative humidity inside a 3013 container and the initiation and propagation of localized corrosion, especially stress corrosion cracking. The integrated plan is being conducted by Los Alamos National Laboratory and SRNL. SRNL is responsible for conducting a corrosion study in small scale vessels containing plutonium oxide and chloride salts under conditions of humidity, temperature and oxide/salt compositions both within the limits of 3013 storage conditions as well as beyond the 3013 storage requirements to identify margins for minimizing the initiation of stress corrosion cracking. These worst case conditions provide data that bound the material packaged in 3013 containers. Phase I of this testing was completed in 2010. The Phase II, Series 1 testing was performed to verify previous results from Phase I testing and extend our understanding about the initiation of stress corrosion cracking and pitting that occur in 304L under conditions of room temperature, high humidity, and a specific plutonium oxide/salt chemistry. These results will aid in bounding the safe storage conditions of plutonium oxides in 3013 containers. A substantial change in the testing was the addition of the capability to monitor relative humidity during test exposure. The results show that under conditions of high initial moisture ({approx}0.5 wt%) and room temperature stress corrosion cracking occurred in 304L teardrop coupons in contact with the oxide/salt mixture at times as short as 85 days. In all cases, the cracking appeared to be associated with pitting or localized general corrosion. Crack initiation at other sites, such as surface imperfections or inclusions, cannot be excluded. Cracks appear in most cases to initiate through an intergranular mode and transition to a transgranular mode.

  13. Ferrocyanide safety program: Results of relative humidity experiments using ferrocyanide waste simulants

    SciTech Connect (OSTI)

    King, C.V.

    1994-10-01

    To be categorized as conditionally safe, ferrocyanide tanks containing {ge} 8 wt% Na{sub 2}NiFe(CN){sub 6} on an energy equivalent basis (i.e., {ge} 115 cal/g) are required to contain some amount of water. These tests were conducted to determine the equilibrium moisture content of waste simulant at the conditions of 30% relative humidity and 25{degrees}C. This test report was prepared to disseminate data collected from these tests. These data are used to model the waste tank moisture contents and transport. These models can determine if the moisture in these tanks will drop below the defined safety limits.

  14. Energy Retrofit Field Study and Best Practices in a Hot-Humid Climate

    SciTech Connect (OSTI)

    McIvaine, J.; Sutherland, K.; Martin, E.

    2013-03-01

    Energy efficiency improvement as a component of comprehensive renovation was investigated under U.S. Department of Energy (DOE) funding of the Building America Partnership for Improved Residential Construction (BA-PIRC). Researchers at the Florida Solar Energy Center (FSEC) worked with affordable housing partners renovating foreclosed homes built from the 1950's through the 2000's in the hot-humid climate (within the Southern census region), primarily in Florida. Researchers targeted a 30% improvement in whole-house energy efficiency along with the health and safety, durability, and comfort guidelines outlined in DOE's Builders Challenge Program (Version 1) Quality Criteria.

  15. Thermodynamic Modeling of a Membrane Dehumidification System 

    E-Print Network [OSTI]

    Bynum, John 1983-

    2012-11-28

    In warm and humid climates, a primary source of building energy consumption is dehumidification of conditioned air supplied to the building spaces. The proposed system utilizes a selective membrane to remove water vapor ...

  16. Reference electrode for electrolytic cell

    DOE Patents [OSTI]

    Kessie, R.W.

    1988-07-28

    A reference electrode device is provided for a high temperature electrolytic cell used to electrolytically recover uranium from spent reactor fuel dissolved in an anode pool, the device having a glass tube to enclose the electrode and electrolyte and serve as a conductive membrane with the cell electrolyte, and an outer metal tube about the glass tube to serve as a shield and basket for any glass sections broken by handling of the tube to prevent their contact with the anode pool, the metal tube having perforations to provide access between the bulk of the cell electrolyte and glass membrane. 4 figs.

  17. Electrolytic cell with reference electrode

    DOE Patents [OSTI]

    Kessie, Robert W. (Naperville, IL)

    1989-01-01

    A reference electrode device is provided for a high temperature electrolytic cell used to electrolytically recover uranium from spent reactor fuel dissolved in an anode pool, the device having a glass tube to enclose the electrode and electrolyte and serve as a conductive membrane with the cell electrolyte, and an outer metal tube about the glass tube to serve as a shield and basket for any glass sections broken by handling of the tube to prevent their contact with the anode pool, the metal tube having perforations to provide access between the bulk of the cell electrolyte and glass membrane.

  18. Approaches to 30% Energy Savings at the Community Scale in the Hot-Humid Climate

    SciTech Connect (OSTI)

    Thomas-Rees, S.; Beal, D.; Martin, E.; Fonorow, K.

    2013-03-01

    BA-PIRC has worked with several community-scale builders within the hot humid climate zone to improve performance of production, or community scale, housing. Tommy Williams Homes (Gainesville, FL), Lifestyle Homes (Melbourne, FL), and Habitat for Humanity (various locations, FL) have all been continuous partners of the BA Program and are the subjects of this report to document achievement of the Building America goal of 30% whole house energy savings packages adopted at the community scale. The scope of this report is to demonstrate achievement of these goals though the documentation of production-scale homes built cost-effectively at the community scale, and modeled to reduce whole-house energy use by 30% in the Hot Humid climate region. Key aspects of this research include determining how to evolve existing energy efficiency packages to produce replicable target savings, identifying what builders' technical assistance needs are for implementation and working with them to create sustainable quality assurance mechanisms, and documenting the commercial viability through neutral cost analysis and market acceptance. This report documents certain barriers builders overcame and the approaches they implemented in order to accomplish Building America (BA) Program goals that have not already been documented in previous reports.

  19. Investigating packaging effects on bandgap references

    E-Print Network [OSTI]

    Palakodety, Ravi (Ravi Kiran)

    2007-01-01

    This thesis investigates packaging effects on precision bandgap voltage references used in LTC switching regulators. Packaging stress causes a mean offset and room temperature distribution widening of the bandgap reference ...

  20. National Environmental Information Infrastructure Reference Architecture

    E-Print Network [OSTI]

    Greenslade, Diana

    National Environmental Information Infrastructure Reference Architecture Consultation Draft Contributing to the Australian Government National Plan for Environmental Information initiative #12;National Environmental Information Infrastructure Reference Architecture: Consultation Draft Environmental Information

  1. Sandia Energy - Reference Model Project (RMP)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Project (RMP) Home Stationary Power Energy Conversion Efficiency Water Power Reference Model Project (RMP) Reference Model Project (RMP)Tara Camacho-Lopez2015-05-11T21:01:36+00:00...

  2. Charting Future Directions for Reference Service

    E-Print Network [OSTI]

    Stratton, John M.; Devlin, Frances A.

    2011-10-18

    reference desks. Reference questions were coded using a taxonomy based on subject headings used to organize databases into broad categories, in addition to corresponding to professional schools within the University. Using our earlier study as a point...

  3. Superconductor rotor cooling system

    DOE Patents [OSTI]

    Gamble, Bruce B.; Sidi-Yekhlef, Ahmed; Schwall, Robert E.; Driscoll, David I.; Shoykhet, Boris A.

    2004-11-02

    A system for cooling a superconductor device includes a cryocooler located in a stationary reference frame and a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with a rotating reference frame in which the superconductor device is located. A method of cooling a superconductor device includes locating a cryocooler in a stationary reference frame, and transferring heat from a superconductor device located in a rotating reference frame to the cryocooler through a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with the rotating reference frame.

  4. Superconductor rotor cooling system

    DOE Patents [OSTI]

    Gamble, Bruce B. (Wellesley, MA); Sidi-Yekhlef, Ahmed (Framingham, MA); Schwall, Robert E. (Northborough, MA); Driscoll, David I. (South Euclid, OH); Shoykhet, Boris A. (Beachwood, OH)

    2002-01-01

    A system for cooling a superconductor device includes a cryocooler located in a stationary reference frame and a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with a rotating reference frame in which the superconductor device is located. A method of cooling a superconductor device includes locating a cryocooler in a stationary reference frame, and transferring heat from a superconductor device located in a rotating reference frame to the cryocooler through a closed circulation system external to the cryocooler. The closed circulation system interfaces the stationary reference frame with the rotating reference frame.

  5. Generic Argillite/Shale Disposal Reference Case

    SciTech Connect (OSTI)

    Zheng, Liange; Colon, Carlos Jové; Bianchi, Marco; Birkholzer, Jens

    2014-08-08

    Radioactive waste disposal in a deep subsurface repository hosted in clay/shale/argillite is a subject of widespread interest given the desirable isolation properties, geochemically reduced conditions, and widespread geologic occurrence of this rock type (Hansen 2010; Bianchi et al. 2013). Bianchi et al. (2013) provides a description of diffusion in a clay-hosted repository based on single-phase flow and full saturation using parametric data from documented studies in Europe (e.g., ANDRA 2005). The predominance of diffusive transport and sorption phenomena in this clay media are key attributes to impede radionuclide mobility making clay rock formations target sites for disposal of high-level radioactive waste. The reports by Hansen et al. (2010) and those from numerous studies in clay-hosted underground research laboratories (URLs) in Belgium, France and Switzerland outline the extensive scientific knowledge obtained to assess long-term clay/shale/argillite repository isolation performance of nuclear waste. In the past several years under the UFDC, various kinds of models have been developed for argillite repository to demonstrate the model capability, understand the spatial and temporal alteration of the repository, and evaluate different scenarios. These models include the coupled Thermal-Hydrological-Mechanical (THM) and Thermal-Hydrological-Mechanical-Chemical (THMC) models (e.g. Liu et al. 2013; Rutqvist et al. 2014a, Zheng et al. 2014a) that focus on THMC processes in the Engineered Barrier System (EBS) bentonite and argillite host hock, the large scale hydrogeologic model (Bianchi et al. 2014) that investigates the hydraulic connection between an emplacement drift and surrounding hydrogeological units, and Disposal Systems Evaluation Framework (DSEF) models (Greenberg et al. 2013) that evaluate thermal evolution in the host rock approximated as a thermal conduction process to facilitate the analysis of design options. However, the assumptions and the properties (parameters) used in these models are different, which not only make inter-model comparisons difficult, but also compromise the applicability of the lessons learned from one model to another model. The establishment of a reference case would therefore be helpful to set up a baseline for model development. A generic salt repository reference case was developed in Freeze et al. (2013) and the generic argillite repository reference case is presented in this report. The definition of a reference case requires the characterization of the waste inventory, waste form, waste package, repository layout, EBS backfill, host rock, and biosphere. This report mainly documents the processes in EBS bentonite and host rock that are potentially important for performance assessment and properties that are needed to describe these processes, with brief description other components such as waste inventory, waste form, waste package, repository layout, aquifer, and biosphere. A thorough description of the generic argillite repository reference case will be given in Jové Colon et al. (2014).

  6. Semantic Features for Classifying Referring Search Terms

    SciTech Connect (OSTI)

    May, Chandler J.; Henry, Michael J.; McGrath, Liam R.; Bell, Eric B.; Marshall, Eric J.; Gregory, Michelle L.

    2012-05-11

    When an internet user clicks on a result in a search engine, a request is submitted to the destination web server that includes a referrer field containing the search terms given by the user. Using this information, website owners can analyze the search terms leading to their websites to better understand their visitors needs. This work explores some of the features that can be used for classification-based analysis of such referring search terms. We present initial results for the example task of classifying HTTP requests countries of origin. A system that can accurately predict the country of origin from query text may be a valuable complement to IP lookup methods which are susceptible to the obfuscation of dereferrers or proxies. We suggest that the addition of semantic features improves classifier performance in this example application. We begin by looking at related work and presenting our approach. After describing initial experiments and results, we discuss paths forward for this work.

  7. Intel C++ Compiler User and Reference Guides

    E-Print Network [OSTI]

    Nikolic, Branislav K.

    Intel® C++ Compiler User and Reference Guides Document number: 304968-022US #12;Disclaimer) 2001, Hewlett-Packard Development Company, L.P. #12;#12;v Table of Contents Intel(R) C++ Compiler User and Reference Guides..............................................1 Intel® C++ Compiler User and Reference

  8. Reference Phase of Fresnel Zone Plates

    E-Print Network [OSTI]

    G. W. Webb

    2003-02-28

    The standard zone plate assumes that the shortest ray connecting a radiation source and a detection point has a phase of 0 deg thereby defining a reference phase. Here we examine the experimental consequences of varying this reference phase from 0 deg to 360 deg. It is concluded that reference phase is an intrinsic and useful property of zone plates.

  9. Direct-to-digital holography reduction of reference hologram noise and fourier space smearing

    DOE Patents [OSTI]

    Voelkl, Edgar

    2006-06-27

    Systems and methods are described for reduction of reference hologram noise and reduction of Fourier space smearing, especially in the context of direct-to-digital holography (off-axis interferometry). A method of reducing reference hologram noise includes: recording a plurality of reference holograms; processing the plurality of reference holograms into a corresponding plurality of reference image waves; and transforming the corresponding plurality of reference image waves into a reduced noise reference image wave. A method of reducing smearing in Fourier space includes: recording a plurality of reference holograms; processing the plurality of reference holograms into a corresponding plurality of reference complex image waves; transforming the corresponding plurality of reference image waves into a reduced noise reference complex image wave; recording a hologram of an object; processing the hologram of the object into an object complex image wave; and dividing the complex image wave of the object by the reduced noise reference complex image wave to obtain a reduced smearing object complex image wave.

  10. Bibliography of the Scripps Institution of Oceanography Reference Series 2001

    E-Print Network [OSTI]

    Criqui, Nan P.; Kuhns, Kittie K.

    2002-01-01

    Scripps Institution of Oceanography Reference Series 2001.SCRIPPS INSTITUTION OF OCEANOGRAPHY REFERENCE SERIES 01-01

  11. WECC Variable Generation Planning Reference Book: Appendices

    SciTech Connect (OSTI)

    Makarov, Yuri V.; Du, Pengwei; Etingov, Pavel V.; Ma, Jian; Vyakaranam, Bharat

    2013-05-13

    The document titled “WECC Variable Generation Planning Reference Book”. This book is divided into two volumes; one is the main document (volume 1)and the other is appendices (volume 2). The main document is a collection of the best practices and the information regarding the application and impact of variables generation on power system planning. This volume (appendices) has additional information on the following topics: Probabilistic load flow problems. 2. Additional useful indices. 3. high-impact low-frequency (HILF) events. 4. Examples of wide-area nomograms. 5. Transmission line ratings, types of dynamic rating methods. 6. Relative costs per MW-km of different electric power transmission technologies. 7. Ultra-high voltage (UHV) transmission. 8.High voltage direct current (VSC-HVDC). 9. HVDC. 10. Rewiring of existing transmission lines. 11. High-temperature low sag (HTLS) conductors. 12. The direct method and energy functions for transient stability analysis in power systems. 13.Blackouts caused by voltage instability. 14. Algorithm for parameter continuation predictor-corrector methods. 15. Approximation techniques available for security regions. 16. Impacts of wind power on power system small signals stability. 17. FIDVR. 18. FACTS. 19. European planning standard and practices. 20. International experience in wind and solar energy sources. 21. Western Renewable Energy Zones (WREZ). 22. various energy storage technologies. 23. demand response. 24. BA consolidation and cooperation options. 25. generator power management requirements and 26. European planning guidelines.

  12. Influence of humidity on the scattering of {gamma}-rays in soil

    SciTech Connect (OSTI)

    Cortes, M. L.; Melo, L. M.; Cristancho, F.

    2010-08-04

    Transmission and backscattering of {gamma}-rays have been used to study soil properties such as its porosity, hydraulic conductivity and also for the detection of organic material buried in soil. These applications require a deeper understanding of the interaction of {gamma}-rays with soil. In the present work a study of the interaction of 511 keV {gamma}-rays with layers of sand varying both its humidity and thickness is presented. The experimental set-up uses the positron decay of a {sup 22}Na source, and two gamma detectors connected in fast time-coincidence. Both transmitted and backscattered spectra are obtained. For transmission, the photopeak and the low angle scattered photons are studied, and for backscattering we analyze the number of single and multiple backscattered photons as a function of thickness. Finally, a theoretical model for the derivative of the number of backscattered photons as a function of depth is presented.

  13. Approaches to 30 Percent Energy Savings at the Community Scale in the Hot-Humid Climate

    SciTech Connect (OSTI)

    Thomas-Rees, S.; Beal, D.; Martin, E.

    2013-03-01

    BA-PIRC has worked with several community-scale builders within the hot humid climate zone to improve performance of production, or community scale, housing. Tommy Williams Homes (Gainesville, FL), Lifestyle Homes (Melbourne, FL), and Habitat for Humanity (various locations, FL) have all been continuous partners of the Building America program and are the subjects of this report to document achievement of the Building America goal of 30% whole house energy savings packages adopted at the community scale. Key aspects of this research include determining how to evolve existing energy efficiency packages to produce replicable target savings, identifying what builders' technical assistance needs are for implementation and working with them to create sustainable quality assurance mechanisms, and documenting the commercial viability through neutral cost analysis and market acceptance. This report documents certain barriers builders overcame and the approaches they implemented in order to accomplish Building America (BA) Program goals that have not already been documented in previous reports.

  14. Reducing Thermal Losses and Gains With Buried and Encapsulated Ducts in Hot-Humid Climates

    SciTech Connect (OSTI)

    Shapiro, C.; Magee, A.; Zoeller, W.

    2013-02-01

    The Consortium for Advanced Residential Buildings (CARB) monitored three houses in Jacksonville, FL, to investigate the effectiveness of encapsulated and encapsulated/buried ducts in reducing thermal losses and gains from ductwork in unconditioned attics. Burying ductwork beneath loose-fill insulation has been identified as an effective method of reducing thermal losses and gains from ductwork in dry climates, but it is not applicable in humid climates where condensation may occur on the outside of the duct jacket. By encapsulating the ductwork in closed cell polyurethane foam (ccSPF) before burial beneath loose-fill mineral fiber insulation, the condensation potential may be reduced while increasing the R-value of the ductwork.

  15. Lead Research and Development Activity for DOE's High Temperature, Low Relative Humidity Membrane Program (Topic 2)

    SciTech Connect (OSTI)

    James Fenton, PhD; Darlene Slattery, PhD; Nahid Mohajeri, PhD

    2012-09-05

    The Department of Energy’s High Temperature, Low Relative Humidity Membrane Program was begun in 2006 with the Florida Solar Energy Center (FSEC) as the lead organization. During the first three years of the program, FSEC was tasked with developing non-Nafion® proton exchange membranes with improved conductivity for fuel cells. Additionally, FSEC was responsible for developing protocols for the measurement of in-plane conductivity, providing conductivity measurements for the other funded teams, developing a method for through-plane conductivity and organizing and holding semiannual meetings of the High Temperature Membrane Working Group (HTMWG). The FSEC membrane research focused on the development of supported poly[perfluorosulfonic acid] (PFSA) – Teflon membranes and a hydrocarbon membrane, sulfonated poly(ether ether ketone). The fourth generation of the PFSA membrane (designated FSEC-4) came close to, but did not meet, the Go/No-Go milestone of 0.1 S/cm at 50% relative humidity at 120 °C. In-plane conductivity of membranes provided by the funded teams was measured and reported to the teams and DOE. Late in the third year of the program, DOE used this data and other factors to decide upon the teams to continue in the program. The teams that continued provided promising membranes to FSEC for development of membrane electrode assemblies (MEAs) that could be tested in an operating fuel cell. FSEC worked closely with each team to provide customized support. A logic flow chart was developed and discussed before MEA fabrication or any testing began. Of the five teams supported, by the end of the project, membranes from two of the teams were easily manufactured into MEAs and successfully characterized for performance. One of these teams exceeded performance targets, while the other requires further optimization. An additional team developed a membrane that shows great promise for significantly reducing membrane costs and increasing membrane lifetime.

  16. Reference wind farm selection for regional wind power prediction models

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    1 Reference wind farm selection for regional wind power prediction models Nils Siebert George.siebert@ensmp.fr, georges.kariniotakis@ensmp.fr Abstract Short-term wind power forecasting is recognized today as a major requirement for a secure and economic integration of wind generation in power systems. This paper deals

  17. Constraint Management in Fuel Cells: A Fast Reference Governor Approach

    E-Print Network [OSTI]

    Stefanopoulou, Anna

    admissible current demand to the fuel cell based on on-line optimization of a scalar parameter and onConstraint Management in Fuel Cells: A Fast Reference Governor Approach Ardalan Vahidi Ilya Kolmanovsky Anna Stefanopoulou Abstract-- The air supply system in a fuel cell may be susceptible

  18. Air Conditioner Efficiency Under Hot Dry and Hot Humid Conditions - The Utility Perspective 

    E-Print Network [OSTI]

    Amarnath, A.

    2008-01-01

    Despite the recent growth of social media, rhetorical theory which addresses authorship in this realm has been slow to develop. Static terms such as "reader," "writer," and "author" are often used to refer to the roles ...

  19. Humidity Effects on PFPE Lubricant Bonding to a-CHx Ryan Z. Lei and Andrew J. Gellman*

    E-Print Network [OSTI]

    Gellman, Andrew J.

    Humidity Effects on PFPE Lubricant Bonding to a-CHx Overcoats Ryan Z. Lei and Andrew J. Gellman will place severe stress on the lubricant and overcoat used to protect the surfaces of magnetic media the lubricant-overcoat interactions become increasingly important to the tribological performance of the head

  20. Tribology Letters Vol. 12, No. 2, February 2002 ( 2002) 105 Effect of humidity on lubricated carbon overcoats

    E-Print Network [OSTI]

    Gellman, Andrew J.

    Tribology Letters Vol. 12, No. 2, February 2002 ( 2002) 105 Effect of humidity on lubricated carbon to measure the adsorption of contaminants on the surfaces of lubricated carbon overcoats such as those used) of amorphous hydrogenated carbon (a-CHx) that is then covered with an even thinner film (10 Å) of lubricants

  1. ANALYSIS OF OFF-GRID, OFF-PIPE HOUSING FOR HOT-HUMID AND HOT-ARID CLIMATES 

    E-Print Network [OSTI]

    Malhotra, M.; Haberl, J.

    2008-01-01

    This paper investigates the feasibility of off-grid, off-pipe housing in hot-humid and hot-arid climates in the U.S. The study aims to eliminate the need for non-renewable sources of energy and municipal water in residences by using off-grid, off...

  2. An Analysis of Low Cost, Energy Efficient, Housing for Low-income Residents of How and Humid Climates 

    E-Print Network [OSTI]

    Kootin-Sanwu, Victor

    2004-01-01

    The purpose of this research is to develop methods that will enable the reduction of owning and operating costs of low-income housing in the hot-humid climates of the U. S. The objectives include investigating various scenarios that will enable...

  3. SAPHIRE 8 Volume 2 - Technical Reference

    SciTech Connect (OSTI)

    C. L. Smith; S. T. Wood; W. J. Galyean; J. A. Schroeder; M. B. Sattison

    2011-03-01

    The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of computer programs that were developed to create and analyze probabilistic risk assessment (PRAs). Herein information is provided on the principles used in the construction and operation of Version 8.0 of the SAPHIRE system. This report summarizes the fundamental mathematical concepts of sets and logic, fault trees, and probability. This volume then describes the algorithms used to construct a fault tree and to obtain the minimal cut sets. It gives the formulas used to obtain the probability of the top event from the minimal cut sets, and the formulas for probabilities that apply for various assumptions concerning reparability and mission time. It defines the measures of basic event importance that SAPHIRE can calculate. This volume gives an overview of uncertainty analysis using simple Monte Carlo sampling or Latin Hypercube sampling, and states the algorithms used by this program to generate random basic event probabilities from various distributions. Also covered are enhance capabilities such as seismic analysis, Workspace algorithms, cut set "recovery," end state manipulation, and use of "compound events."

  4. SAM Photovoltaic Model Technical Reference

    SciTech Connect (OSTI)

    Gilman, P.

    2015-05-27

    This manual describes the photovoltaic performance model in the System Advisor Model (SAM). The U.S. Department of Energy’s National Renewable Energy Laboratory maintains and distributes SAM, which is available as a free download from https://sam.nrel.gov. These descriptions are based on SAM 2015.1.30 (SSC 41).

  5. Modelling the influence of temperature and relative humidity on the time-dependent mechanical behaviour of a short glass fibre reinforced polyamide

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    . Introduction Carmakers are facing the challenge of reducing CO2 emis- sions, and are thus strongly interested. Both temperature and relative humidity are known to have an impact on mechanical properties strength of SGFR polyamides is highly sensitive to both temperature and relative humidity (Bernasconi et al

  6. Internship Checklist Ready Reference C-3

    E-Print Network [OSTI]

    Internship Checklist Ready Reference C-3 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of Engineering, Architecture & Technology Career Services Office

  7. Cover Letter Formula Ready Reference F-3

    E-Print Network [OSTI]

    Cover Letter Formula Ready Reference F-3 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of Engineering, Architecture & Technology Career Services Office

  8. Letter of Refusal Ready Reference F-8

    E-Print Network [OSTI]

    Letter of Refusal Ready Reference F-8 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of College of Engineering, Architecture & Technology Career

  9. Sample Withdrawal Letter Ready Reference F-11

    E-Print Network [OSTI]

    Sample Withdrawal Letter Ready Reference F-11 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of College of Engineering, Architecture & Technology

  10. Sample Application Letter Ready Reference F-5

    E-Print Network [OSTI]

    Sample Application Letter Ready Reference F-5 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of College of Engineering, Architecture & Technology

  11. Sample Networking Letter Ready Reference F-6

    E-Print Network [OSTI]

    Sample Networking Letter Ready Reference F-6 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of College of Engineering, Architecture & Technology

  12. Sample Acceptance Letter Ready Reference F-10

    E-Print Network [OSTI]

    Sample Acceptance Letter Ready Reference F-10 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of College of Engineering, Architecture & Technology

  13. Job Search Steps Ready Reference D-1

    E-Print Network [OSTI]

    Job Search Steps Ready Reference D-1 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of Engineering, Architecture & Technology Career Services Office

  14. Preparing A Vita Ready Reference E-13

    E-Print Network [OSTI]

    Preparing A Vita Ready Reference E-13 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of Engineering, Architecture & Technology Career Services Office

  15. FAQS Reference Guide – Facility Maintenance Management

    Office of Energy Efficiency and Renewable Energy (EERE)

    This reference guide addresses the competency statements in the April 2014 edition of DOE Standard DOE-STD-1181-2014, Facility Maintenance Management Functional Area Qualification Standard.

  16. FAQS Reference Guide – NNSA Package Certification Engineer

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the February 2009 edition of DOE-STD-1026-2009, NNSA Package Certification Engineer Functional Area Qualification Standard.

  17. FAQS Reference Guide – General Technical Base

    Broader source: Energy.gov [DOE]

    This reference guide addresses the competency statements in the December 2007 edition of DOE-STD-1146-2007, General Technical Base Functional Area Qualification Standard.

  18. EERE Program Management Quick Reference Guide

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Office of Energy Efficiency and Renewable Energy (EERE) Program Management Reference Guide. It provides an overall description of the EERE program management structure, defines...

  19. Reference Designs for Hydrogen Fueling Stations Webinar

    Broader source: Energy.gov [DOE]

    Access the recording and download the presentation slides from the Fuel Cell Technologies Office webinar "Reference Designs for Hydrogen Fueling Stations" held on October 13, 2015.

  20. REFERENCE CASES FOR USE IN THE CEMENTITOUS PARTNERSHIP PROJECT

    SciTech Connect (OSTI)

    Langton, C.; Kosson, D.; Garrabrants, A.

    2010-08-31

    The Cementitious Barriers Partnership Project (CBP) is a multi-disciplinary, multi-institution cross cutting collaborative effort supported by the US Department of Energy (DOE) to develop a reasonable and credible set of tools to improve understanding and prediction of the structural, hydraulic and chemical performance of cementitious barriers used in nuclear applications. The period of performance is >100 years for operating facilities and > 1000 years for waste management. The CBP has defined a set of reference cases to provide the following functions: (i) a common set of system configurations to illustrate the methods and tools developed by the CBP, (ii) a common basis for evaluating methodology for uncertainty characterization, (iii) a common set of cases to develop a complete set of parameter and changes in parameters as a function of time and changing conditions, (iv) a basis for experiments and model validation, and (v) a basis for improving conceptual models and reducing model uncertainties. These reference cases include the following two reference disposal units and a reference storage unit: (i) a cementitious low activity waste form in a reinforced concrete disposal vault, (ii) a concrete vault containing a steel high-level waste tank filled with grout (closed high-level waste tank), and (iii) a spent nuclear fuel basin during operation. Each case provides a different set of desired performance characteristics and interfaces between materials and with the environment. Examples of concretes, grout fills and a cementitious waste form are identified for the relevant reference case configurations.

  1. CRYSTALLINE CERAMIC WASTE FORMS: REFERENCE FORMULATION REPORT

    SciTech Connect (OSTI)

    Brinkman, K.; Fox, K.; Marra, J.

    2012-05-15

    The research conducted in this work package is aimed at taking advantage of the long term thermodynamic stability of crystalline ceramics to create more durable waste forms (as compared to high level waste glass) in order to reduce the reliance on engineered and natural barrier systems. Durable ceramic waste forms that incorporate a wide range of radionuclides have the potential to broaden the available disposal options and to lower the storage and disposal costs associated with advanced fuel cycles. Assemblages of several titanate phases have been successfully demonstrated to incorporate radioactive waste elements, and the multiphase nature of these materials allows them to accommodate variation in the waste composition. Recent work has shown that they can be successfully produced from a melting and crystallization process. The objective of this report is to explain the design of ceramic host systems culminating in a reference ceramic formulation for use in subsequent studies on process optimization and melt property data assessment in support of FY13 melter demonstration testing. The waste stream used as the basis for the development and testing is a combination of the projected Cs/Sr separated stream, the Trivalent Actinide - Lanthanide Separation by Phosphorous reagent Extraction from Aqueous Komplexes (TALSPEAK) waste stream consisting of lanthanide fission products, the transition metal fission product waste stream resulting from the transuranic extraction (TRUEX) process, and a high molybdenum concentration with relatively low noble metal concentrations. In addition to the combined CS/LN/TM High Mo waste stream, variants without Mo and without Mo and Zr were also evaluated. Based on the results of fabricating and characterizing several simulated ceramic waste forms, two reference ceramic waste form compositions are recommended in this report. The first composition targets the CS/LN/TM combined waste stream with and without Mo. The second composition targets with CS/LN/TM combined waste stream with Mo and Zr removed. Waste streams that contain Mo must be produced in reducing environments to avoid Cs-Mo oxide phase formation. Waste streams without Mo have the ability to be melt processed in air. A path forward for further optimizing the processing steps needed to form the targeted phase assemblages is outlined in this report. Processing modifications including melting in a reducing atmosphere, and controlled heat treatment schedules are anticipated to improve the targeted elemental partitioning.

  2. Development of Reference Models and Design Tools (LCOE Models...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Development of Reference Models and Design Tools (LCOE Models) Development of Reference Models and Design Tools (LCOE Models) Development of Reference Models and Design Tools (LCOE...

  3. Federal Employee Training Desk Reference | Department of Energy

    Energy Savers [EERE]

    College of Learning and Workforce Development Federal Employee Training Desk Reference Federal Employee Training Desk Reference The DOE Federal Employee Training Desk Reference...

  4. Mixed waste characterization reference document

    SciTech Connect (OSTI)

    1997-09-01

    Waste characterization and monitoring are major activities in the management of waste from generation through storage and treatment to disposal. Adequate waste characterization is necessary to ensure safe storage, selection of appropriate and effective treatment, and adherence to disposal standards. For some wastes characterization objectives can be difficult and costly to achieve. The purpose of this document is to evaluate costs of characterizing one such waste type, mixed (hazardous and radioactive) waste. For the purpose of this document, waste characterization includes treatment system monitoring, where monitoring is a supplement or substitute for waste characterization. This document establishes a cost baseline for mixed waste characterization and treatment system monitoring requirements from which to evaluate alternatives. The cost baseline established as part of this work includes costs for a thermal treatment technology (i.e., a rotary kiln incinerator), a nonthermal treatment process (i.e., waste sorting, macronencapsulation, and catalytic wet oxidation), and no treatment (i.e., disposal of waste at the Waste Isolation Pilot Plant (WIPP)). The analysis of improvement over the baseline includes assessment of promising areas for technology development in front-end waste characterization, process equipment, off gas controls, and monitoring. Based on this assessment, an ideal characterization and monitoring configuration is described that minimizes costs and optimizes resources required for waste characterization.

  5. Archived Reference Building Type: Primary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  6. Archived Reference Building Type: Primary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  7. OUTLOOK -MOBILE DEVICE ACCESS QUICK REFERENCE GUIDE

    E-Print Network [OSTI]

    Liley, David

    th OUTLOOK - MOBILE DEVICE ACCESS QUICK REFERENCE GUIDE Quick Reference Guide is designed to step you through the initial set up of your Outlook email account on your Mac. Note: If you're opening Microsoft Outlook 2011 for the first time, you will see the Welcome to Microsoft Outlook for Mac window

  8. OUTLOOK -MOBILE DEVICE ACCESS QUICK REFERENCE GUIDE

    E-Print Network [OSTI]

    Liley, David

    th OUTLOOK - MOBILE DEVICE ACCESS QUICK REFERENCE GUIDE This Quick Reference Guide is designed to step you through the setup of your Outlook email account on your mobile device. When to use this Guide is Outlook. NOTE: After you have set up your account you must remove your old GWSync account ITS

  9. Archived Reference Building Type: Secondary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  10. Archived Reference Building Type: Secondary school

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  11. Archived Reference Building Type: Medium office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  12. Archived Reference Building Type: Medium office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  13. Archived Reference Building Type: Outpatient health care

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  14. Archived Reference Building Type: Outpatient health care

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  15. Intel Fortran Compiler User and Reference Guides

    E-Print Network [OSTI]

    Nikolic, Branislav K.

    Intel® Fortran Compiler User and Reference Guides Document number: 304970-005US #12;Disclaimer) 2001, Hewlett-Packard Development Company, L.P. #12;#12;v Table of Contents Intel(R) Fortran Compiler User and Reference Guides.........................................1 Intel® Fortran Compiler User

  16. Home Energy Rating System Building Energy Simulation Test for Florida (Florida-HERS BESTEST): Tier 1 and Tier 2 Tests; Vol. 1 (User's Manual) and Vol. 2 (Reference Results)

    SciTech Connect (OSTI)

    Judkoff, R.; Neymark, J.

    1997-08-01

    In 1991, the U.S. Department of Energy, in cooperation with the Department of Housing and Urban Development (HUD), initiated a collaborative process to define a residential energy efficiency rating program linked with energy-efficient mortgage (EEM) financing. During this process, the collaborative, consisting of a broad-based group representing stakeholder organizations, identified the need for quality control procedures to evaluate and verify the energy prediction methods used by Home Energy Rating System (HERS) providers. Such procedures were needed so a variety of locally developed rating systems would have equal opportunity to qualify under the umbrella of a national HERS/EEM system by meeting minimum technical requirements (National Renewable Energy Laboratory).

  17. Detection and Prediction of Errors in EPCs of the SAP Reference Model

    E-Print Network [OSTI]

    van der Aalst, Wil

    as a blueprint for roll-out projects of SAP's ERP system. It reflects Version18 4.6 of SAP R/3 which was marketedDetection and Prediction of Errors in EPCs of the SAP Reference Model J. Mendling a, H.M.W. Verbeek provide empirical evidence for these questions based on the SAP reference model. This model collection

  18. Photooxidation of Alpha-Pinene at High Relative Humidity in the Presence of Increasing Concentrations of NOx

    SciTech Connect (OSTI)

    Yu, Yong; Ezell, Michael J.; Zelenyuk, Alla; Imre, Dan G.; Alexander, M. Lizabeth; Ortega, John V.; D'Anna, Barbara; Harmon, Chris W.; Johnson, Stan; Finlayson-Pitts, Barbara J.

    2008-06-01

    The photooxidation of ~1 ppm alpha-pinene in the presence of increasing concentrations of NO2 was studied in a Teflon chamber at relative humidities from 70 - 88% and temperatures from 296 - 304 K. The loss of alpha-pinene and formation of gas phase products were followed using proton transfer reaction mass spectrometry (PTR-MS). Gas phase reaction products measured by PTR-MS and their yields include formaldehyde (5 + 1%), formic acid (2.5 + 1.4%), methanol (0.6 + 0.3%), acetaldehyde (3.9 + 1.7%), acetic acid (10 + 2%), acetone (11.5 + 3.1%), pinonaldehyde (22 + 6%), and pinene oxide (0.9 + 0.1%). There was evidence of organic nitrates in the gas phase and small peaks were tentatively assigned to norpinonaldehyde, 4-oxopinonaldehyde, propanedial, 2,3-dioxobutanal and 3,5,6-trioxoheptanal or 3-hydroxymethyl-2,2-dimethylcyclobutylethanone. The formation and growth of new particles were followed using a scanning mobility particle sizer (SMPS), and their chemical composition was probed using single particle mass spectrometry (SPLAT II). SPLAT II analysis also provided measurements of the vacuum aerodynamic diameters of the newly formed secondary organic aerosol (SOA) particles and, in combination with the electrical mobility diameter, a particle density of 1.21 + 0.02 g cm-3 was calculated, 20% larger than often assumed in calculating SOA yields. SPLAT II showed that the suspended SOA consisted of a complex mixture of organic nitrates and organics, possibly including pinonic acid, pinic acid and trans-sobrerol. Three-wavelength light scattering measurements made using an integrating nephelometer were consistent with particles having a refractive index characteristic of organic compounds, but the data could not be well matched at all three wavelengths with a single refractive index. The effect of addition of cyclohexane or NO on particle formation showed that ozonolysis was the major mechanism of SOA formation in this system. However, unlike simple ozonolysis, organic nitrates are formed in both the gas and particle phases. Identifying and measuring specific organic nitrates in both the gas and particle phases in air may help to elucidate why SOA formation has been reported in field studies to be associated with polluted urban areas, yet the carbon in these particles is largely contemporary, i.e., non-fossil fuel carbon.

  19. Optimization Control Strategy for an Air Handling Unit with Dedicated Rotary Desiccant Dehumidification Wheel in Hot and Humid Climate 

    E-Print Network [OSTI]

    Watt, J.

    2013-01-01

    STRATEGY FOR AN AIR HANDLING UNIT WITH DEDICATED ROTARY DESICCANT DEHUMIDIFICATION WHEEL IN HOT & HUMID CLIMATE Jim Watt Montr?al, Qu?bec October 8, 2013 Outline ? Background ? Introduction?of?desiccant?dehumidification? process ? Mathematical...?Sorption?Process Model?calibration HCU1 HCU2 DB(?F) WB(?F) DB(?F) WB(?F) Inlet 52 52 50 50 Design?outlet 70 54.9 69 53.2 Model?outlet 70.7 55.1 69.7 53.5 Error 0.94% 0.42% 1.03% 0.47% DESCRIPTION?OF?DEDICATED?HUMIDITY? CONTROL?UNITS?(HCU) Run#?1?DESIGN R A W B C...

  20. Fischer-Tropsch synthesis from a low H/sub 2/:CO gas in a dry fluidized-bed system. Technical progress report, September 1, 1982-March 31, 1983. [Large number of references

    SciTech Connect (OSTI)

    Liu, Y.A.; Squires, A.M.; Konrad, K.

    1983-01-01

    The objective of this project is to experimentally develop and demonstrate a novel dry fluidized-bed reactor system (called heat tray) for Fischer-Tropsch synthesis from a low H/sub 2/:CO gas. The new reactor involves conducting catalytic synthesis reactions primarily in a horizontal conveying zone, in which fine particles of iron catalyst are carried in a relatively dilute suspension by a large flow of reacting gas. A secondary reaction zone, in the form of a shallow fluidized bed of catalyst particles, is situated beneath the primary reaction zone. This shallow bed also has immersed horizontal heat-transfer tubes for removing reaction heat. A major thrust of the new reactor development is to prevent carbon deposits from forming on the iron catalyst, which cause deactivation and physical degradation. This is to be achieved by conducting the Fischer-Tropsch synthesis in an unsteady-state mode, particularly by alternately exposing the iron catalyst to a large flow of low H/sub 2/:CO gas for a short period of time and to a small flow of H/sub 2/-rich gas for a long period of time. During the past several months, the design, construction and steady-state testing of a fully-automated vibrofluidized microreactor system have been successfully completed, and a computer-controlled gas chromatographic (GC) system for gas-product analysis has also been tied to the reactor system. Work on unsteady-state Fischer-Tropsch synthesis experiments is to be initiated shortly. In addition, supporting hydrodynamic and heat-transfer studies in several shallow fluidized-bed systems have produced some encouraging data. The results indicate very high heat-transfer coefficients of 300-400 W/m/sup 2/-/sup 0/K between a shallow bed and its immersed horizontal heat-transfer tube, and of about 7000 W/m/sup 2/-/sup 0/K between a supernatant gas stream and a shallow bed which closely simulates the microreactor system in use.

  1. An Experimental Method for Determining the Time Constants of Capacitive Thin-Film Polymer Humidity sensors at Various Duct Air Velocities 

    E-Print Network [OSTI]

    Dooley, B.; O'Neal, D.

    2008-01-01

    of capacitive thin-jïlm polymer humidity sensors to step changes in humidity and temperature as a function of air velocity was investigated. Two duct-mounted humidity sensors (designated Candidate X and Candidate Y) from two manufacturers, each with thin... changes in RH and temperature over a range of air velocities. Duct air velocities ofO (stili air). 200. 500. 800, and UOOft/min (0. 1.0, 2.5. 4.1, and 5.6 m/s) were considered along with .step changes in RH of 20%-40% and step changes in air temperature...

  2. Design and fabrication of a data logger for atmospheric pressure, temperature and relative humidity for gas-filled detector development

    E-Print Network [OSTI]

    Sahu, S; Rudra, Sharmili; Biswas, S; Mohanty, B; Sahu, P K

    2015-01-01

    A novel instrument has been developed to monitor and record the ambient pa- rameters such as temperature, atmospheric pressure and relative humidity. These parameters are very essential for understanding the characteristics such as gain of gas filled detectors like Gas Electron Multiplier (GEM) and Multi Wire Propor- tional Counter (MWPC). In this article the details of the design, fabrication and operation processes of the device has been presented.

  3. The effect of humidity on the collection efficiencies of two monitoring methods when exposed to a mixture of organic solvents 

    E-Print Network [OSTI]

    Rushlow, Lori Ann

    1989-01-01

    the sorbent is zero. ( ) The adsorption process is reversible, so Fick's model cannot be used exclusively as an explanation for the way the OVN operates. A better mathematical model to explain passive dosimetry was developed when general assumptions were...% Relative Humidity. 37 LIST OF FIGURES Figure 1 Figure 2 Figure 3 Figure 4 Schematic Diagram of the Vapor Generation and Exposure Chamber for Acetone and Toluene. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Top and Side View...

  4. Warm Humid Climate: Methodology to Study Air Temperature Distribution: Mobile Phones Base Stations as Viable Alternative for Fixed Points 

    E-Print Network [OSTI]

    Araujo, V.; Costa, A.; Labaki, L.

    2006-01-01

    . The summer period, from October to March is characterized by higher temperatures, lower relative humidity and relatively low wind speeds with southeast predominance, presenting small variations in the direction east - northeast. 2 METHODOLOGY...: METHODOLOGY TO STUDY AIR TEMPERATURE DISTRIBUTION: MOBILE PHONES BASE STATIONS AS VIABLE ALTERNATIVE FOR FIXED POINTS Angelina Dias Leão Costa (1); Lucila Labaki (2); Virgínia Araújo (3) (1) and (2) School of Civil Engineering, Architecture and Urban...

  5. Temperature, humidity and air flow in the emplacement drifts using convection and dispersion transport models

    SciTech Connect (OSTI)

    Danko, G.; Birkholzer, J.T.; Bahrami, D.; Halecky, N.

    2009-10-01

    A coupled thermal-hydrologic-airflow model is developed, solving for the transport processes within a waste emplacement drift and the surrounding rockmass together at the proposed nuclear waste repository at Yucca Mountain. Natural, convective air flow as well as heat and mass transport in a representative emplacement drift during post-closure are explicitly simulated, using the MULTIFLUX model. The conjugate, thermal-hydrologic transport processes in the rockmass are solved with the TOUGH2 porous-media simulator in a coupled way to the in-drift processes. The new simulation results show that large-eddy turbulent flow, as opposed to small-eddy flow, dominate the drift air space for at least 5000 years following waste emplacement. The size of the largest, longitudinal eddy is equal to half of the drift length, providing a strong axial heat and moisture transport mechanism from the hot to the cold drift sections. The in-drift results are compared to those from simplified models using a surrogate, dispersive model with an equivalent dispersion coefficient for heat and moisture transport. Results from the explicit, convective velocity simulation model provide higher axial heat and moisture fluxes than those estimated from the previously published, simpler, equivalent-dispersion models, in addition to showing differences in temperature, humidity and condensation rate distributions along the drift length. A new dispersive model is also formulated, giving a time- and location-variable function that runs generally about ten times higher in value than the highest dispersion coefficient currently used in the Yucca Mountain Project as an estimate for the equivalent dispersion coefficient in the emplacement drift. The new dispersion coefficient variation, back-calculated from the convective model, can adequately describe the heat and mass transport processes in the emplacement drift example.

  6. Oxygen and relative humidity monitoring with films tailored for enhanced photoluminescence

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Cui, Weipan; Liu, Rui; Manna, Eeshita; Park, Joong -Mok; Fungura, Fadzai; Shinar, Joseph; Shinar, Ruth

    2014-10-31

    In this study, approaches to generate porous or doped sensing films, which significantly enhance the photoluminescence (PL) of oxygen optical sensors, and thus improve the signal-to-noise (S/N) ratio, are presented. Tailored films, which enable monitoring the relative humidity (RH) as well, are also presented. Effective porous structures, in which the O2-sensitive dye Pt octaethylporphyrin (PtOEP) or the Pd analog PdOEP was embedded, were realized by first generating blend films of polyethylene glycol (PEG) with polystyrene (PS) or with ethyl cellulose (EC), and then immersing the dried films in water to remove the water-soluble PEG. This approach creates pores (voids) inmore »the sensing films. The dielectric contrast between the films’ constituents and the voids increases photon scattering, which in turn increases the optical path of the excitation light within the film, and hence light absorption by the dye, and its PL. Optimized sensing films with a PEG:PS ratio of 1:4 (PEG’s molecular weight Mw ~8000) led to ~4.4× enhancement in the PL (in comparison to PS films). Lower Mw ~200 PEG with a PEG:EC ratio of 1:1 led to a PL enhancement of ~4.7×. Film-dependent PL enhancements were observed at all oxygen concentrations. The strong PL enhancement enables (i) using lower dye (luminophore) concentrations, (ii) reducing power consumption and enhancing the sensor’s operational lifetime when using organic light emitting diodes (OLEDs) as excitation sources, (iii) improving performance when using compact photodetectors with no internal gain, and (iv) reliably extending the dynamic range.« less

  7. Leucaena and tall grasses as energy crops in humid lower south USA

    SciTech Connect (OSTI)

    Prine, G.M.; Woodard, K.R.; Cunilio, T.V.

    1994-12-31

    The tropical leguminous shrub/tree, leucaena (Leucaena spp. mainly leucocephala), and perennial tropical tall grasses such as elephantgrass (Pennisetum purpureum), sugarcane, and energycane (Saccharum spp.) are well adapted to the long growing seasons and high rainfall of the humid lower South. In much of the area the topgrowth is killed by frost during winter and plants regenerate from underground parts in spring. Selected accessions from a duplicated 373 accession leucaena nursery had an average annual woody stem dry matter production of 31.4 Mg ha{sup -1}. Average oven dry stem wood yields from selected accessions adjusted for environmental enrichment over the 4 growth seasons were 78.9 Mg ha{sup -1} total and average annual yield of 19.7 Mg ha{sup -1}. The tall perennial grasses have linear growth rates of 18 to 27 g m{sup 2}d{sup -1} for long periods (140 to 196 d and sometimes longer) each season. Oven dry biomass yields of tall grasses have varied from 20 to 45 Mg ha{sup -1} in mild temperature locations to over 60 Mg ha{sup -1} yr{sup -1} in warm subtropics of the lower Florida peninsula. Tall grasses and leucaena, once established, may persist for many seasons. A map showing the possible range of the crops in lower South is shown. Highest biomass yields of tall grasses have been produced when irrigated with sewage effluent or when grown on phosphatic clay and muck soils of south Florida. Several companies are considering using leucaena and/or tall grasses for bioenergy in the phosphatic mining area of Polk County, Florida.

  8. LIBRARY AND INFORMATION SERVICES DIVISION Current References

    E-Print Network [OSTI]

    LIBRARY AND INFORMATION SERVICES DIVISION Current References (92 -1) ,..... .. , ... ........,., ECOSYSTEMS OF THE FLORIDA KEYS · A Bibliography U. S. DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration National Environmental Satellite, Data, and Information Service National Oceanographic Data Center

  9. Salary Negotiation Ready ReferenceH-3

    E-Print Network [OSTI]

    Salary Negotiation Ready ReferenceH-3 College of Engineering, Architecture & Technology Career" salary on the top end of your range. Although this range may appear high because it is created from

  10. Writing Career Objectives Ready Reference E-5

    E-Print Network [OSTI]

    Writing Career Objectives Ready Reference E-5 College of Engineering, Architecture & Technology in pharmaceutical research" #12;Oklahoma State University College of Engineering, Architecture & Technology Career your practical skills. Examples: -"A position in a large, high tech organization requiring network

  11. Generic Argillite/Shale Disposal Reference Case

    E-Print Network [OSTI]

    Zheng, Liange

    2014-01-01

    S. and K.S. Johnson, (1984). Shale and other argillaceousand R. T. Cygan, (2010). Shale Disposal of U.S. High-LevelDC. Generic Argillite/Shale Disposal Reference Case August

  12. Archive Reference Buildings by Building Type: Warehouse

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  13. New Construction Commercial Reference Buildings — Archive

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  14. Emergency Responder Radioactive Material Quick Reference Sheet

    Broader source: Energy.gov [DOE]

    This job aid is a quick reference to assist emergency responders in identifying preliminary safety precautions that should be taken during the initial response phase after arrival at the scene of...

  15. FAQS Reference Guide – Civil/ Structural Engineering

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in the March 2004 edition of DOE-STD-1182-2004, Civil/Structural Engineering Functional Area Qualification Standard.

  16. FAQS Reference Guide – Safety Software Quality Assurance

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in the (March 2011) edition of DOE-STD-1172-2011, Safety Software Quality Assurance Functional Area Qualification Standard.

  17. Precision Micropower, Low Dropout Voltage References

    E-Print Network [OSTI]

    Berns, Hans-Gerd

    series references are specified over the extended industrial temperature range (-40°C to +85°C) with typical performance specifications over -40°C to +125°C for applications, such as automotive. All

  18. Archive Reference Buildings by Building Type: Supermarket

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  19. Javarifier : inference of reference immutability in Java

    E-Print Network [OSTI]

    Quinonez, Jamie

    2008-01-01

    Javari is an extension of Java that supports reference immutability constraints. Programmers write Javari type qualifiers, such as the readonly type qualifier, in their programs, and the Javari typechecker detects mutation ...

  20. Generating and interpreting referring expressions in context

    E-Print Network [OSTI]

    Smith, Dustin Arthur

    2013-01-01

    Referring expressions with vague and ambiguous modifiers, such as "a quick visit" and "the big meeting," are difficult for computers to interpret because their meanings are defined in part by context. For the hearer to ...

  1. Integrating Referring and Informing in NP Planning 

    E-Print Network [OSTI]

    O'Donnell, Michael; Knott, Alistair; Hitzeman, Janet; Cheng, Hua

    Two of the functions of an NP are to refer (identify a particular entity) and to inform (provide new information about an entity). While many NPs may serve only one of these functions, some NPs conflate the functions, ...

  2. Population Reference Bureau Kenneth W. Wachter

    E-Print Network [OSTI]

    Wachter, Kenneth W.

    -Recapture Estimates 2. Logistic Regression for Stratum Rates 3. Synthetic Estimation for Small Areas KWW ­ p. 14/2 #12,000 households · American Community Survey: Reverse Record Check KWW ­ p. 20/2 #12;References Bell, Robert and M

  3. An expectation model of referring expressions

    E-Print Network [OSTI]

    Kræmer, John, Ph. D. Massachusetts Institute of Technology

    2010-01-01

    This thesis introduces EMRE, an expectation-based model of referring expressions. EMRE is proposed as a model of non-syntactic dependencies - in particular, discourse-level semantic dependencies that bridge sentence gaps. ...

  4. Quantum communication, reference frames and gauge theory

    E-Print Network [OSTI]

    S. J. van Enk

    2006-04-26

    We consider quantum communication in the case that the communicating parties not only do not share a reference frame but use imperfect quantum communication channels, in that each channel applies some fixed but unknown unitary rotation to each qubit. We discuss similarities and differences between reference frames within that quantum communication model and gauge fields in gauge theory. We generalize the concept of refbits and analyze various quantum communication protocols within the communication model.

  5. "Analysis of SOFCs using reference electrodes?

    SciTech Connect (OSTI)

    Finklea, Harry; Chen,Xiaoke; Gerdes,Kirk; Pakalapati, Suryanarayana; Celik, Ismail

    2013-07-01

    Reference electrodes are frequently applied to isolate the performance of one electrode in a solid oxide fuel cell. However, reference electrode simulations raise doubt to veracity of data collected using reference electrodes. The simulations predict that the reported performance for the one electrode will frequently contain performance of both electrodes. Nonetheless, recent reports persistently treat data so collected as ideally isolated. This work confirms the predictions of the reference electrode simulations on two SOFC designs, and to provides a method of validating the data measured in the 3-electrode configuration. Validation is based on the assumption that a change in gas composition to one electrode does not affect the impedance of the other electrode at open circuit voltage. This assumption is supported by a full physics simulation of the SOFC. Three configurations of reference electrode and cell design are experimentally examined using various gas flows and two temperatures. Impedance data are subjected to deconvolution analysis and equivalent circuit fitting and approximate polarization resistances of the cathode and anode are determined. The results demonstrate that the utility of reference electrodes is limited and often wholly inappropriate. Reported impedances and single electrode polarization values must be scrutinized on this basis.

  6. Can ASHRAE Standard 62-1989 Requirements be Satisfied while Maintaining Moisture Control using Stock HVAC Equipment in Hot, Humid Climates? 

    E-Print Network [OSTI]

    Turner, S. C.

    1996-01-01

    energy costs. Increased ventilation rates create real capital and operating costs for building owners and operators, with implications beyond energy costs relating to increased ventilation requirements. In hot, humid climates, increased ventilation rates...

  7. The Impacts of Indirect Soil Moisture Assimilation and Direct Surface Temperature and Humidity Assimilation on a Mesoscale Model Simulation of an Indian

    E-Print Network [OSTI]

    Niyogi, Dev

    Assimilation on a Mesoscale Model Simulation of an Indian Monsoon Depression VINODKUMAR AND A. CHANDRASEKAR-generation Pennsylvania State University­NCAR Mesoscale Model (MM5) simulation utilized the humidity and temperature

  8. Effectiveness of External Window Attachments Based on Daylight Utilization and Cooling Load Reduction for Small Office Buildings in Hot Humid Climates 

    E-Print Network [OSTI]

    Soebarto, V. I.; Degelman, L. O.

    1994-01-01

    This study explored the effectiveness of selected external shading devices and glazing treatments used to minimize the total annual energy consumption in small office buildings in hot humid climates. The external shading devices included a permanent...

  9. Building America Best Practices Series: Volume 4; Builders and Buyers Handbook for Improving New Home Efficiency, Comfort, and Durability in the Mixed-Humid Climate

    SciTech Connect (OSTI)

    2005-09-01

    This guide book is a resource to help builders large and small build high-quality, energy-efficient homes that achieve 30% energy savings in space conditioning and water heating in the mixed-humid climate region.

  10. Field-Evaluation of Alternative HVAC Strategies to Meet Ventilation, Comfort and Humidity Control Criteria at Three Full-Serve Restaurants 

    E-Print Network [OSTI]

    Yborra, S. C.; Spears, J. W.

    2000-01-01

    Lighting and ventilation represent the majority of the air conditioning loads in office buildings in hot humid climates. Use of motion sensors is one way to minimize the energy used for these loads. This paper describes the methods used...

  11. Bringing simulation to implementation: Presentation of a global approach in the design of passive solar buildings under humid tropical climates

    E-Print Network [OSTI]

    Garde, François; Celaire, Robert

    2012-01-01

    In early 1995, a DSM pilot initiative has been launched in the French islands of Guadeloupe and Reunion through a partnership between several public and private partners (the French Public Utility EDF, the University of Reunion Island, low cost housing companies, architects, energy consultants, etc...) to set up standards to improve thermal design of new residential buildings in tropical climates. This partnership led to defining optimized bio-climatic urban planning and architectural designs featuring the use of passive cooling architectural principles (solar shading, natural ventilation) and components, as well as energy efficient systems and technologies. The design and sizing of each architectural component on internal thermal comfort in building has been assessed with a validated thermal and airflow building simulation software (CODYRUN). These technical specifications have been edited in a reference document which has been used to build over 300 new pilot dwellings through the years 1996-1998 in Reunion...

  12. The design, construction, and instrumentation of a chamber to study heat, mass, and momentum transfer from humid air to metal under conditions of frosting and free convection 

    E-Print Network [OSTI]

    Hutchison, James P

    1961-01-01

    THE DESIGN? CONSTRUCTION? AND INSTRUMENTATION OF A CEAMSER TO STUDY HEAT, MASS? AND MOSNTUM TRANSFER FROM HUMID AIR TO METAL UNDER CONDITIONS OF FROSTING AND FREE CONVECTION A Thesis By James P. Hutchison Submitted to the Graduate School..., AND MOMENTUM TRANSFER FROM HUMID AIR TO METAL UNDER CONDITIONS OF FROSTING AND FREE CONVECTION A Thesis By James P. Hutchison Approved as to Style and Content: Chairman of Committee Head of Departm t + gkA4; August 1961 ACKNOWLEDGEMENT S The writer...

  13. Tracking stochastic resonance curves using an assisted reference model

    SciTech Connect (OSTI)

    Calderón Ramírez, Mario; Rico Martínez, Ramiro; Parmananda, P.

    2015-06-15

    The optimal noise amplitude for Stochastic Resonance (SR) is located employing an Artificial Neural Network (ANN) reference model with a nonlinear predictive capability. A modified Kalman Filter (KF) was coupled to this reference model in order to compensate for semi-quantitative forecast errors. Three manifestations of stochastic resonance, namely, Periodic Stochastic Resonance (PSR), Aperiodic Stochastic Resonance (ASR), and finally Coherence Resonance (CR) were considered. Using noise amplitude as the control parameter, for the case of PSR and ASR, the cross-correlation curve between the sub-threshold input signal and the system response is tracked. However, using the same parameter the Normalized Variance curve is tracked for the case of CR. The goal of the present work is to track these curves and converge to their respective extremal points. The ANN reference model strategy captures and subsequently predicts the nonlinear features of the model system while the KF compensates for the perturbations inherent to the superimposed noise. This technique, implemented in the FitzHugh-Nagumo model, enabled us to track the resonance curves and eventually locate their optimal (extremal) values. This would yield the optimal value of noise for the three manifestations of the SR phenomena.

  14. Fuel cell gas management system

    DOE Patents [OSTI]

    DuBose, Ronald Arthur (Marietta, GA)

    2000-01-11

    A fuel cell gas management system including a cathode humidification system for transferring latent and sensible heat from an exhaust stream to the cathode inlet stream of the fuel cell; an anode humidity retention system for maintaining the total enthalpy of the anode stream exiting the fuel cell equal to the total enthalpy of the anode inlet stream; and a cooling water management system having segregated deionized water and cooling water loops interconnected by means of a brazed plate heat exchanger.

  15. Study on The Intelligence Control System of Artificial Cooling Source in Architecture 

    E-Print Network [OSTI]

    Yang, Z.; Xu, X.

    2006-01-01

    To overcome the shortcoming of constant temperature and humidity in artificial cooling source control system, a dynamic indoor temperature control strategy was put forward under health and thermal comfortable principles. With a lump human model...

  16. Numerical Analysis of Heat and Moisture Transfer in Underground Air-conditioning Systems 

    E-Print Network [OSTI]

    Wang, Q.; Miao, X.; Cheng, B.; Fan, L.

    2006-01-01

    In view of the influence of humidity of room air on room heat load, indoor environment and building energy consumption in underground intermittent air-conditioning systems, numerical simulation was used to dynamically analyze the coupling condition...

  17. Design of Flat-Plate Dehumidifiers for Humidification–Dehumidification Desalination Systems

    E-Print Network [OSTI]

    Sievers, Martin

    Flat-plate heat exchangers are examined for use as dehumidifiers in humidification–dehumidification (HDH) desalination systems. The temperature and humidity ratio differences that drive mass transfer are considerably higher ...

  18. References - DOE Directives, Delegations, and Requirements

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II) by Carbon-RichProtonAbout Us HanfordReference MaterialsReference Shelf

  19. Corrosion problems in Ti/KC1O/sub 4/ loaded devices when subjected to humid environments

    SciTech Connect (OSTI)

    Massis, T.M.; Healey, J.T.; Huskisson, D.H.; Perkins, W.G.

    1980-01-01

    A piston motor/igniter loaded with a Ti/KClO/sub 4/ pyrotechnic and sealed with a silicone adhesive exhibited serious corrosion problems during aging. Five 24-hour thermal cycles between room temperature and 71/sup 0/C at 90% relative humidity resulted in extensive surface corrosion of the Kovar pins and severe stress corrosion cracking of the Kovar pins in the vicinity of the bridgewire weld. No corrosion or cracking of the Nichrome bridgewire was observed. Similar results were observed after 60 days at 50% and 90% relative humidity at room temperature. Tests at ambient relative humidity and room temperature caused limited surface corrosion and no observable cracking. It was determined that these problems resulted from the combined presence of chlorine containing contaminants and atmospheric moisture. Chlorine was detected in both the surface corrosion product and the corrosion product in the subsurface cracks. The absence of reaction and/or morphological alteration of the Ti/KClO/sub 4/ at the pyrotechnic interface with the Kovar indicated the pyrotechnic was not involved in the corrosion reaction, and, hence, the chlorine was present in the surface contamination on the Kovar pins. The aging tests indicate that external moisture was involved in the corrosion reaction. Calculation and experimentation have shown the silicone adhesive used to seal these devices to be permeable to water vapor, and the moisture conditions inside the devices equilibrated with external conditions within a few hours. Corrosion and cracking could be solved by eliminating the source of moisture by hermetically sealing the devices. Tests of hermetically sealed units have confirmed this conclusion.

  20. NIST Standard Reference Database 23 NIST Reference Fluid Thermodynamic and Transport Properties--

    E-Print Network [OSTI]

    measurements and models we have taken from the literature, and without which this database would be much#12;NIST Standard Reference Database 23 NIST Reference Fluid Thermodynamic and Transport Properties (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data

  1. Fast Response and High Sensitivity ZnO/glass Surface Acoustic Wave Humidity Sensors Using Graphene Oxide Sensing Layer

    E-Print Network [OSTI]

    Xuan, Weipeng; He, Mei; Meng, Nan; He, Xingli; Wang, Wenbo; Chen, Jinkai; Shi, Tianjin; Hasan, Tawfique; Xu, Zhen; Xu, Yang; Luo, J. K.

    2014-11-26

    FT-IR spectrum obtained from our GO samples. A strong and broad valley at 3413 cm21 is attributed to the -OH groups in stretching vibrations. This peak implies the good hydro- philicity of the GO samples used for our humidity sensing. Other absorption... the resonance and sensitivity of the SAW devices. Our approach of using an optimized proper thickness of GO layer over the whole surface of the SAW sensors provides a very large effective sensing surface for moisture adsorption without affecting the per...

  2. Risk Management Steering Committee Terms of Reference

    E-Print Network [OSTI]

    Victoria, University of

    Risk Management Steering Committee Terms of Reference October 2009 1.0 Purpose The purposes Facilities Management Risk and Insurance Analyst Associate Vice-President Human Resources Administrative of the Steering Committee are: a) to follow a continuous process to understand and communicate risk from

  3. The Behavioral Interview Ready Reference G-7

    E-Print Network [OSTI]

    The Behavioral Interview Ready Reference G-7 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of College of Engineering, Architecture & Technology in technical and high tech industries within the last 10 years. Behavioral interviews are designed to focus

  4. Questioning Yourself Ready Reference B-2

    E-Print Network [OSTI]

    Questioning Yourself Ready Reference B-2 College of Engineering, Architecture & Technology Career Services Oklahoma State University College of Engineering, Architecture & Technology Career Services Office set my own hours? Do I thrive in a high-stress atmosphere, or would I prefer something a bit more

  5. INVESTIGATION Construction of Reference Chromosome-Scale

    E-Print Network [OSTI]

    Douches, David S.

    INVESTIGATION Construction of Reference Chromosome-Scale Pseudomolecules for Potato: Integrating was genotyped with several types of molecular genetic markers to construct a new ~936 cM linkage map comprising and orientation within the pseudo- molecules are closely collinear with independently constructed high density

  6. Quick-Reference Guide to Optimization with

    E-Print Network [OSTI]

    Nikolic, Branislav K.

    Quick-Reference Guide to Optimization with Intel® Compilers version 11 For IA-32 processors, Intel, you may want to check correctness of your application by building it without optimization using /Od (-O0). In this compiler version, all optimization levels assume support for the SSE2 instruction set

  7. Previous Up Next Article From References: 0

    E-Print Network [OSTI]

    Ottino, Julio M.

    (e.g. laminar) fluid flow. Two decades of interdisciplinary studies in this line of investigationPrevious Up Next Article Citations From References: 0 From Reviews: 0 MR2265644 (Review) 37N10 (37D in applications: micro to macro, fluids to solids. Cambridge Monographs on Applied and Computational Mathematics

  8. Xyce parallel electronic simulator : reference guide.

    SciTech Connect (OSTI)

    Mei, Ting; Rankin, Eric Lamont; Thornquist, Heidi K.; Santarelli, Keith R.; Fixel, Deborah A.; Coffey, Todd Stirling; Russo, Thomas V.; Schiek, Richard Louis; Warrender, Christina E.; Keiter, Eric Richard; Pawlowski, Roger Patrick

    2011-05-01

    This document is a reference guide to the Xyce Parallel Electronic Simulator, and is a companion document to the Xyce Users Guide. The focus of this document is (to the extent possible) exhaustively list device parameters, solver options, parser options, and other usage details of Xyce. This document is not intended to be a tutorial. Users who are new to circuit simulation are better served by the Xyce Users Guide. The Xyce Parallel Electronic Simulator has been written to support, in a rigorous manner, the simulation needs of the Sandia National Laboratories electrical designers. It is targeted specifically to run on large-scale parallel computing platforms but also runs well on a variety of architectures including single processor workstations. It also aims to support a variety of devices and models specific to Sandia needs. This document is intended to complement the Xyce Users Guide. It contains comprehensive, detailed information about a number of topics pertinent to the usage of Xyce. Included in this document is a netlist reference for the input-file commands and elements supported within Xyce; a command line reference, which describes the available command line arguments for Xyce; and quick-references for users of other circuit codes, such as Orcad's PSpice and Sandia's ChileSPICE.

  9. Hazard Communication Program 1.0 REFERENCE

    E-Print Network [OSTI]

    de Lijser, Peter

    Hazard Communication Program 1.0 REFERENCE California Code of Regulations, Title 8, Sections 337 the properties and potential safety and health hazards of the materials which they use or to which they are exposed. Employees who use or may be exposed to potentially hazardous substances or harmful physical

  10. UNIVERSITY PLANNING (SCUP) Terms of Reference

    E-Print Network [OSTI]

    Lennard, William N.

    UNIVERSITY PLANNING (SCUP) Terms of Reference: The Committee is the chief forum within Senate for critical appraisal and coordination of long-term strategic, capital and budget plans for the University planning context, it has specific responsibilities as follows: Long-Range Planning To review and recommend

  11. Campus Planning Committee Terms of Reference

    E-Print Network [OSTI]

    Victoria, University of

    1 Campus Planning Committee Terms of Reference Type: Advisory to President Charge: 1. Recognizing the academic priorities of the institution, the Committee shall advise the President on: a) the long-range plan for the physical development of the Campus; b) amendments to the approved campus plan; c) the University's proposed

  12. Fluid Neutral Momentum Transport Reference Problem

    E-Print Network [OSTI]

    Budny, Robert

    Fluid Neutral Momentum Transport Reference Problem D. P. Stotler, PPPL S. I. Krasheninnikov, UCSD 1 Summary Type of problem: kinetic or fluid neutral transport Physics or algorithm stressed: thermal force term (spatial resolution) in momentum transport equation and treatment of collisions (charge ex- change

  13. Shape Recipes: Scene Representations that Refer

    E-Print Network [OSTI]

    Freeman, William T.

    Shape Recipes: Scene Representations that Refer to the Image William T. Freeman and Antonio to estimate and store. We propose a low-dimensional rep- resentation, called a scene recipe, that relies on the image itself to de- scribe the complex scene configurations. Shape recipes are an example

  14. Macrosegregation Macrosegregation refers to variations in composition

    E-Print Network [OSTI]

    Beckermann, Christoph

    in casting processes: (i) Flow that feeds the solidification shrinkage and the contractions of the liquidMacrosegregation Macrosegregation refers to variations in composition that occur in alloy castings variations have a detrimental impact on the subsequent processing behavior and properties of cast materials

  15. R Reference Manual: A gentle overview

    E-Print Network [OSTI]

    Priestley, Jennifer Lewis

    , yet similar to SAS, R is a commands-driven programming environment to execute statistical analysisR Reference Manual: A gentle overview #12;2 Developed and maintained by the Center for Statistics statistical computing packages ­ Excel, SPSS, Minitab, R and SAS. 1 Readers of this manual are assumed to have

  16. Bibliography of the Scripps Institution of Oceanography Reference Series 1994

    E-Print Network [OSTI]

    Criqui, Nan P.

    1995-01-01

    OF THE SCRIPPS INSTITUTION OF OCEANOGRAPHY REFERENCE SERIESScripps Institution of Oceanography. July 1994. 179p. 94-17Scripps Institution of Oceanography Reference Series 1994.

  17. Bibliography of the Scripps Institution of Oceanography Reference Series 1997

    E-Print Network [OSTI]

    Jennings, Paige A.

    1998-01-01

    SCRIPPS INSTITUTION OF OCEANOGRAPHY REFERENCE SERIES 97-01Scripps Institution of Oceanography Reference Series 1997.held at Scripps Institution of Oceanography 19 August 1997.

  18. Biomass Scenario Model Documentation: Data and References Lin...

    Office of Scientific and Technical Information (OSTI)

    Documentation: Data and References Lin, Y.; Newes, E.; Bush, B.; Peterson, S.; Stright, D. 09 BIOMASS FUELS BIOMASS SCENARIO MODEL; BSM; BIOMASS; BIOFUEL; MODEL; DATA; REFERENCES;...

  19. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Reference Buildings by Climate Zone and Representative City: 4B Albuquerque, New Mexico Reference Buildings by Climate Zone and Representative City: 4B Albuquerque, New...

  20. A Method for Calculating Reference Evapotranspiration on Daily Time Scales

    E-Print Network [OSTI]

    Farmer, William

    Measures of reference evapotranspiration are essential for applications of agricultural management and water resources engineering. Using numerous esoteric variables, one can calculate daily reference evapotranspiration ...

  1. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    akfairbanksnew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 8 Fairbanks, Alaska Reference Buildings by Climate Zone...

  2. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    atxhoustonnew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 2A Houston, Texas Reference Buildings by Climate Zone...

  3. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    mdbaltimorenew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 4A Baltimore, Maryland Reference Buildings by Climate...

  4. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    agaatlantanew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 3A Atlanta, Georgia Reference Buildings by Climate Zone...

  5. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    usaflmiaminew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 1A Miami, Florida Reference Buildings by Climate Zone...

  6. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    samthelenanew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 6B Helena, Montana Reference Buildings by Climate Zone...

  7. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    acobouldernew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 5B Boulder, Colorado Reference Buildings by Climate...

  8. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    awaseattlenew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 4C Seattle, Washington Reference Buildings by Climate...

  9. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    nvlasvegasnew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 3B Las Vegas, Nevada Reference Buildings by Climate...

  10. Reference Model 5 (RM5): Oscillating Surge Wave Energy Converter

    SciTech Connect (OSTI)

    Yu, Y. H.; Jenne, D. S.; Thresher, R.; Copping, A.; Geerlofs, S.; Hanna, L. A.

    2015-01-01

    This report is an addendum to SAND2013-9040: Methodology for Design and Economic Analysis of Marine Energy Conversion (MEC) Technologies. This report describes an Oscillating Water Column Wave Energy Converter (OSWEC) reference model design in a complementary manner to Reference Models 1-4 contained in the above report. A conceptual design for a taut moored oscillating surge wave energy converter was developed. The design had an annual electrical power of 108 kilowatts (kW), rated power of 360 kW, and intended deployment at water depths between 50 m and 100 m. The study includes structural analysis, power output estimation, a hydraulic power conversion chain system, and mooring designs. The results were used to estimate device capital cost and annual operation and maintenance costs. The device performance and costs were used for the economic analysis, following the methodology presented in SAND2013-9040 that included costs for designing, manufacturing, deploying, and operating commercial-scale MEC arrays up to 100 devices. The levelized cost of energy estimated for the Reference Model 5 OSWEC, presented in this report, was for a single device and arrays of 10, 50, and 100 units, and it enabled the economic analysis to account for cost reductions associated with economies of scale. The baseline commercial levelized cost of energy estimate for the Reference Model 5 device in an array comprised of 10 units is $1.44/kilowatt-hour (kWh), and the value drops to approximately $0.69/kWh for an array of 100 units.

  11. REFERENCE: The Blue Planet An Introduction to Earth System

    E-Print Network [OSTI]

    Gilbes, Fernando

    ;Microparticles suspended in a gas (such as air). Ex. Aerogel or "Frozen smoke". Extremely fine particles

  12. REFERENCE: The Blue Planet An Introduction to Earth System

    E-Print Network [OSTI]

    Gilbes, Fernando

    ;#12;Wind blowing across the ocean in the northern hemisphere affects the surface water, producing a net is away from the land, rising subsurface water replaces water moving offshore, producing upwelling. Winds. Murck (2011) Third Edition. John Wiley and Sons Inc. #12;Atlantic Ocean Caribbean Sea Gulf of Mexico

  13. REFERENCE: The Blue Planet An Introduction to Earth System

    E-Print Network [OSTI]

    Gilbes, Fernando

    Hutton incorporated the idea of uplift and erosion into the concept of the rock cycle. · In the 1830s continually around the solid inner core. The flowing stream of molten iron causes an electrical current

  14. REFERENCE: The Blue Planet An Introduction to Earth System

    E-Print Network [OSTI]

    Gilbes, Fernando

    ;#12;Nuclear power is the use of sustained nuclear fission to generate heat and electricity. Nuclear power sensing can be combined with on-site mapping to assess changes in the extent and health of forest cover

  15. REFERENCE: The Blue Planet An Introduction to Earth System

    E-Print Network [OSTI]

    Gilbes, Fernando

    : Is the process by which hot, less dense materials rise upward and are replaced by cold, more dense materials = (2.8 x1023 m2)(1370 W/m2) = 3.8 x 1026 watts 1 watt (W) = J/s #12;The fusion process: Nuclear produces its energy by two fusion reactions: 1. Proton-Proton (PP) ­ 88% 2. Carbon-Nitrogen-Oxygen (CNO

  16. REFERENCE: The Blue Planet An Introduction to Earth System

    E-Print Network [OSTI]

    Gilbes, Fernando

    a progressive shift, or precession, of the spring and autumn equinoxes, with each cycle lasting about 23

  17. Water Rights Analysis Package (WRAP) Modeling System Reference Manual 

    E-Print Network [OSTI]

    Wurbs, Ralph A.

    2003-01-01

    .............................................................................................. 106 Hydroelectric Energy ......................................................................................................... 107 Instream Flow Requirements... called TAMUWRAP, stemmed from a 1986-1988 research project at Texas A&M University (TAMU) entitled Optimizing Reservoir Operations in Texas sponsored by a federal/state cooperative research program administered by the U.S. Geological Survey (USGS...

  18. REFERENCE: The Blue Planet An Introduction to Earth System

    E-Print Network [OSTI]

    Gilbes, Fernando

    : IS THE ENERGY FROM THE SUN THAT ACTUALLY REACHES THE EARTH'S SURFACE. The atmosphere gets its heat energy from the Sun. The flux of energy coming from the Sun is 1370 W/m2. This is the energy flux that would. · Ozone absorbs ultraviolet radiation coming from the Sun. · This absorption converts the energy of the UV

  19. REFERENCE: The Blue Planet An Introduction to Earth System

    E-Print Network [OSTI]

    Gilbes, Fernando

    (start of toolmaking), the Agricultural Revolution (origin of agriculture) and the modern Industrial population, lifestyle, technology, and the environment. #12;Actual Times 0 Technological Revolution Human population has grown in exponential surges after each of the great "revolutions": the Neolithic Revolution

  20. Reference Model for Control and Automation Systems in Electrical Power

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergy AEnergyPresidentialThis 3-DMarch 9, 2015 Cumulative'' issued by(October 2005) |

  1. FAQS Reference Guide - Electrical Systems and Safety Oversight |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum12, 2015Executive Order 13514ConstructionWeapon Quality AssuranceDepartment of

  2. Reference Model for Control and Automation Systems in Electrical Power

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on DeliciousMathematicsEnergyInterested PartiesBuildingBudgetFinancial Opportunities » PastamsReducing

  3. Quantum chaos and order based on classically moving reference frames

    SciTech Connect (OSTI)

    Hai Wenhua [Department of Physics, Hunan Normal University, Changsha 410081 (China); Department of Physics, Jishou University, Jishou 416000, Hunan (China); Xie Qiongtao; Fang Jianshu [Department of Physics, Hunan Normal University, Changsha 410081 (China)

    2005-07-15

    We develop a mathematically consistent approach for treating the quantum systems based on moving classical reference frames. The classical and quantum exact solutions show excellently classical-quantum correspondence, in which the quantum chaotic coherent states correspond to the classically chaotic motions. Applying the approach to the periodically driven linear and nonlinear oscillators, the regular and chaotic quantum states and quantum levels, and the quantum chaotic regions are evidenced. The results indicate that chaos may cause the collapse of matter wave packets and suppress the quantum effect of energy.

  4. JEDI Marine and Hydrokinetic Model: User Reference Guide

    SciTech Connect (OSTI)

    Goldberg, M.; Previsic, M.

    2011-04-01

    The Jobs and Economic Development Impact Model (JEDI) for Marine and Hydrokinetics (MHK) is a user-friendly spreadsheet-based tool designed to demonstrate the economic impacts associated with developing and operating MHK power systems in the United States. The JEDI MHK User Reference Guide was developed to assist users in using and understanding the model. This guide provides information on the model's underlying methodology, as well as the sources and parameters used to develop the cost data utilized in the model. This guide also provides basic instruction on model add-in features, operation of the model, and a discussion of how the results should be interpreted.

  5. NREL Solar Radiation Research Laboratory (SRRL): Baseline Measurement System (BMS); Golden, Colorado (Data)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Stoffel, T.; Andreas, A.

    1981-07-15

    The SRRL was established at the Solar Energy Research Institute (now NREL) in 1981 to provide continuous measurements of the solar resources, outdoor calibrations of pyranometers and pyrheliometers, and to characterize commercially available instrumentation. The SRRL is an outdoor laboratory located on South Table Mountain, a mesa providing excellent solar access throughout the year, overlooking Denver. Beginning with the basic measurements of global horizontal irradiance, direct normal irradiance and diffuse horizontal irradiance at 5-minute intervals, the SRRL Baseline Measurement System now produces more than 130 data elements at 1-min intervals that are available from the Measurement & Instrumentation Data Center Web site. Data sources include global horizontal, direct normal, diffuse horizontal (from shadowband and tracking disk), global on tilted surfaces, reflected solar irradiance, ultraviolet, infrared (upwelling and downwelling), photometric and spectral radiometers, sky imagery, and surface meteorological conditions (temperature, relative humidity, barometric pressure, precipitation, snow cover, wind speed and direction at multiple levels). Data quality control and assessment include daily instrument maintenance (M-F) with automated data quality control based on real-time examinations of redundant instrumentation and internal consistency checks using NREL's SERI-QC methodology. Operators are notified of equipment problems by automatic e-mail messages generated by the data acquisition and processing system. Radiometers are recalibrated at least annually with reference instruments traceable to the World Radiometric Reference (WRR).

  6. NREL Solar Radiation Research Laboratory (SRRL): Baseline Measurement System (BMS); Golden, Colorado (Data)

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Stoffel, T.; Andreas, A.

    The SRRL was established at the Solar Energy Research Institute (now NREL) in 1981 to provide continuous measurements of the solar resources, outdoor calibrations of pyranometers and pyrheliometers, and to characterize commercially available instrumentation. The SRRL is an outdoor laboratory located on South Table Mountain, a mesa providing excellent solar access throughout the year, overlooking Denver. Beginning with the basic measurements of global horizontal irradiance, direct normal irradiance and diffuse horizontal irradiance at 5-minute intervals, the SRRL Baseline Measurement System now produces more than 130 data elements at 1-min intervals that are available from the Measurement & Instrumentation Data Center Web site. Data sources include global horizontal, direct normal, diffuse horizontal (from shadowband and tracking disk), global on tilted surfaces, reflected solar irradiance, ultraviolet, infrared (upwelling and downwelling), photometric and spectral radiometers, sky imagery, and surface meteorological conditions (temperature, relative humidity, barometric pressure, precipitation, snow cover, wind speed and direction at multiple levels). Data quality control and assessment include daily instrument maintenance (M-F) with automated data quality control based on real-time examinations of redundant instrumentation and internal consistency checks using NREL's SERI-QC methodology. Operators are notified of equipment problems by automatic e-mail messages generated by the data acquisition and processing system. Radiometers are recalibrated at least annually with reference instruments traceable to the World Radiometric Reference (WRR).

  7. Indoor air movement acceptability and thermal comfort in hot-humid climates

    E-Print Network [OSTI]

    Candido, Christhina Maria

    2010-01-01

    is heavily weighted towards hydroelectricity, accounting forof rain to drive hydroelectricity generation) and inadequatelack of rain for the hydroelectricity based system) and poor

  8. Indoor air movement acceptability and thermal comfort in hot-humid climates

    E-Print Network [OSTI]

    Candido, Christhina Maria

    2010-01-01

    energy efficiency with the majority of electricity consumption attributed to lighting and air-conditioningair-conditioning and lighting systems without any consideration for energy efficiency

  9. AN OVERVIEW OF BUILDING AMERICA INDUSTRIALIZED HOUSING PARTNERSHIP (BAIHP) ACTIVITIES IN HOT-HUMID CLIMATES 

    E-Print Network [OSTI]

    Chandra, S.; Parker, D.; Sherwin, J.; Colon, C.; Fonorow, K.; Stroer, D.; Martin, E.; McIlvaine, J.; Chasar, D.; Moyer, N.; Thomas-Rees, S.; Hoak, D.; Beal, D.; Gil, C.

    2008-01-01

    -by-side testing is to enhance and validate simulation models for solar water heating systems, particularly the integrated collector and storage (ICS) systems. The three solar collectors have been installed (Figure 6), and the tank and tankless systems... Geothermal, closed vertical loop a/c size (@hi spd), sq. ft/ton 723 818 760 1,044 Dehumidifier No No No Yes Hot water Solar w/electric backup ?open loop, pumped w/ 40 sf /80 gal. Tank Solar w/electric backup, drainback system, w/ 64 sf /120...

  10. Influence of the hydration by the environmental humidity on the metallic speciation and the photocatalytic activity of Cr/MCM-41

    SciTech Connect (OSTI)

    Elías, Verónica R.; Sabre, Ema V.; Winkler, Elin L.; Andrini, Leandro; Requejo, Félix G.; Casuscelli, Sandra G.; Eimer, Griselda A.

    2014-05-01

    The influence of the environmental humidity on the Cr species deposited on inorganic supports like MCM-41 silicates was analyzed by UV–vis Diffuse Reflectance (UV–vis RD), Electronic Spin Resonance (ESR) and X-ray near-edge (XANES) spectroscopy. Metal speciation could be inferred, finding that prolonged exposure periods under environmental humidity provoked the reduction of the active Cr{sup 6+} species and thus, the decrease of the Cr/MCM-41 photoactivity. After the Ti loading over the Cr modified samples, Cr species and the photoactivity were not notably influenced by the humidity exposure. Thus, it could be concluded that the presence of Ti is important because the TiO{sub 2} cover protects the oxidized Cr species, stabilizing them. - Graphical abstract: The load of Ti on the Cr modified MCM-41 produces a TiO{sub 2} cover that protects the active Cr species from their reduction by the environmental humidity. - Highlights: • Spectroscopic analysis shows presence of Cr{sup 6+}/Cr{sup 5+} in calcined/re-calcined samples. • Cr{sup 3+} species increase for hydrated samples causing their photoactivity decrease. • Samples with high Cr loadings are more sensitive to environmental humidity presence. • TiO{sub 2} cover protects oxidized Cr species from their reduction by the water. • Ti is important to allow a synergistic effect and to stabilize active Cr{sup 6+}/Cr{sup 5+}.

  11. Development of Temperature and Humidity-Based Indicators for Diagnosing Problems in Low Tonnage, Split System Air Conditioners 

    E-Print Network [OSTI]

    Watt, J. B.; O'Neal, D. L.; Haberl, J. S.

    1998-01-01

    with the ability to use either a short-tube orifice (STO) or a thermal expansion valve (TXV). The degraded conditions studied include low evaporator airflow, high- and low- charge, and a blocked condenser coil. The empirical work was performed to identify.... The original work showed that low-cost temperature sensors can be used to detect the degraded conditions studied. However, it also showed that the temperature-based indicators of low evaporator airflow depend on three loading factors; outdoor...

  12. Performance and Optimization of an Underfloor Air Distribution System in an Educational Building in a Hot and Humid Climate 

    E-Print Network [OSTI]

    Khmelenko, Vasiliy

    2015-05-01

    Temperatures Supply Plenum Leaving Temperature Supply Plenum Enetering Temperature 29 between 0°C and 10 °C, an average of 2.9 Btu/ft2 between 20°C and 30°C, and a peak of 5.9 Btu/ft2 at 37°C. The variance of heat gain at each temperature is smaller at lower...

  13. Wall Design Redundancy for Improving the Moisture Performance of Building Cladding Systems in Hot-Humid Climates 

    E-Print Network [OSTI]

    Graham, C. W.

    2000-01-01

    problem for building owners. In recent years reports of damage to building envelope components, including rot of wood framing and corrosion of metal earning and fasteners, have increased dramatically. For example, numerous reports of water... the wood fiaming supporting their cladding. Water-related problems with EIFS in over 300 homes in the Wilmington, North Carolina area were reported by the NAHB Research Center in 1996, and before that in the same area by the Wilrnington Section...

  14. Ventilation Requirements in Hot Humid Iain S. Walker and Max H. Sherman

    E-Print Network [OSTI]

    for Energy Efficiency and Renewable Energy, Office of the Building Technologies Program, U.S. Department HVAC system operation, such as the lack of dehumidification from typical air conditioning systems Environmental Energy Technologies Division August 2006 This work was supported by the Assistant Secretary

  15. Reference Design? | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onRAPID/Geothermal/Exploration/Colorado <RAPID/Geothermal/WaterEnergyRedfield CampusReedsville,Reference Design? Home

  16. High Flux Isotope Reactor cold neutron source reference design concept

    SciTech Connect (OSTI)

    Selby, D.L.; Lucas, A.T.; Hyman, C.R.

    1998-05-01

    In February 1995, Oak Ridge National Laboratory`s (ORNL`s) deputy director formed a group to examine the need for upgrades to the High Flux Isotope Reactor (HFIR) system in light of the cancellation of the Advanced neutron Source Project. One of the major findings of this study was that there was an immediate need for the installation of a cold neutron source facility in the HFIR complex. In May 1995, a team was formed to examine the feasibility of retrofitting a liquid hydrogen (LH{sub 2}) cold source facility into an existing HFIR beam tube. The results of this feasibility study indicated that the most practical location for such a cold source was the HB-4 beam tube. This location provides a potential flux environment higher than the Institut Laue-Langevin (ILL) vertical cold source and maximizes the space available for a future cold neutron guide hall expansion. It was determined that this cold neutron beam would be comparable, in cold neutron brightness, to the best facilities in the world, and a decision was made to complete a preconceptual design study with the intention of proceeding with an activity to install a working LH{sub 2} cold source in the HFIR HB-4 beam tube. During the development of the reference design the liquid hydrogen concept was changed to a supercritical hydrogen system for a number of reasons. This report documents the reference supercritical hydrogen design and its performance. The cold source project has been divided into four phases: (1) preconceptual, (2) conceptual design and testing, (3) detailed design and procurement, and (4) installation and operation. This report marks the conclusion of the conceptual design phase and establishes the baseline reference concept.

  17. An Experimental Evaluation of the Time Response of a Duct-Mounted Relative Humidity Sensors 

    E-Print Network [OSTI]

    Joshi, S.N.; Pate, M.B.; Nelson, R.M.; House, J.H.; Klaassen, C.J.

    2007-01-01

    This work is aimed towards the development of an artificially intelligent search algorithm used in conjunction with an Auto Associative Neural Network (AANN) to help locate and reconstruct faulty sensor inputs in control systems. The AANN can...

  18. Enthalpy Wheels Come of Age: Applying Energy Recovery Ventilation to Hospitality Venues in Hot, Humid Climate 

    E-Print Network [OSTI]

    Wellford, B. W.

    2000-01-01

    Energy recovery ventilation systems, including rotary heat exchangers or enthalpy wheels, utilize mature technologies that are routinely applied in commercial buildings. Energy recovery is particularly important in buildings with significant outdoor...

  19. An analysis of maximum residential energy-efficiency in hot and humid climates 

    E-Print Network [OSTI]

    Malhotra, Mini

    2006-04-12

    Energy-efficient building design involves minimizing the energy use and optimizing the performance of individual systems and components of the building. The benefits of energyefficient design, in the residential sector, ...

  20. Residential Slab-On-Grade Heat Transfer in Hot Humid Climates 

    E-Print Network [OSTI]

    Clark, E.; Ascolese, M.; Collins, W.

    1989-01-01

    Heat transfer through an uninsulated slab on grade is calculated using a simple method developed by Kusuda. The seasonal and annual slab loads are graphed as a function of annual average soil temperature, Tm, for a variety of floor system...

  1. Indoor climate and moisture durability performances of houses with unvented attic roof constructions in a mixed-humid climate.

    SciTech Connect (OSTI)

    Pallin, Simon B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Boudreaux, Philip R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jackson, Roderick K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-10-01

    A sealed or unvented attic is an energy-efficient envelope component that can reduce the amount of energy a house consumes for space conditioning if the air handler and/or ducts are located in the attic. The attic is typically sealed by using spray foam on the underside of the roof deck and covering the soffit, ridge and gable vents to minimize air leakage from the attic to the outside. This approach can save up to 10% in space-conditioning energy when ducts are located in the attic (DOE 2013). Past research done by ORNL and Florida Solar Energy Center suggests that in more hot, humid climates, an unvented attic could potentially create a more humid, uncomfortable living environment than a vented attic (Colon 2011, Boudreaux, Pallin et al. 2013). Research showed that controlling the higher indoor humidity could reduce the energy savings from the sealed, unvented attic, which in turn would decrease the energy savings payback. Research also showed that the roof assembly (5.5 inches of open-cell foam, 1inch of closed-cell foam, OSB, felt paper, and asphalt shingles) stored moisture, thus acting as a moisture buffer. During the fall and winter, the roof assembly stored moisture and during the spring and summer it released moisture. This phenomenon is not seen in a vented attic, in which the air exchange rate to the outside is greater and, in the winter, helps to dehumidify the attic air. It was also seen that in a vented attic, the direction of water vapor diffusion is on average from the attic to the interior of the house. Air leakage from the attic to the interior also occurs during more of the year in a house with an unvented attic than in one with a vented attic. These discoveries show that the moisture dynamics in a house with an unvented attic are much different from those in a house with a vented attic. This study reports on a series of computer model investigations completed to determine the key variables impacting indoor comfort and the durability of roof assemblies against moisture. The key variables investigated were the leakage area from the attic to the outside, leakage area from the attic to the interior, leakage area from the interior to the outside, supply duct leakage in the attic, and interior moisture generation. These investigations are described in this report.

  2. Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate, Cocoa, Florida (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-04-01

    Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC has conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season. ?

  3. The use of data from the NIMBUS II satellite to determine the mean relative humidity in the layer below 500 mb 

    E-Print Network [OSTI]

    Morrissette, John Francis

    1967-01-01

    of the requirements for the degree of MASTER OF SCIENCE May 1967 Major Subject: METEOROLOGY THE USE OF DATA FROM THE NIMBUS II SATELLITE TO DETERMINE THE MEAN RELATIVE HUMIDITY IN THE LAYER BELON 5OO MB A Thesis By JOHN FRANCIS MORRISSFTTE Approved... as to style and content by: (Ch rrman of Committee) (Head of Departme & (Member) (Member) (Member) May 1967 ABSTRACT The Use of Data From the NIMBUS II Satellite to Determine the Mean Relative Humidity in the Layer Below 500 mb. (May 1967) John Francis...

  4. Technology Solutions Case Study: Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate

    SciTech Connect (OSTI)

    2014-04-01

    Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.

  5. Department of Energy Construction Safety Reference Guide

    SciTech Connect (OSTI)

    Not Available

    1993-09-01

    DOE has adopted the Occupational Safety and Health Administration (OSHA) regulations Title 29 Code of Federal Regulations (CFR) 1926 ``Safety and Health Regulations for Construction,`` and related parts of 29 CFR 1910, ``Occupational Safety and Health Standards.`` This nonmandatory reference guide is based on these OSHA regulations and, where appropriate, incorporates additional standards, codes, directives, and work practices that are recognized and accepted by DOE and the construction industry. It covers excavation, scaffolding, electricity, fire, signs/barricades, cranes/hoists/conveyors, hand and power tools, concrete/masonry, stairways/ladders, welding/cutting, motor vehicles/mechanical equipment, demolition, materials, blasting, steel erection, etc.

  6. 1993 Solid Waste Reference Forecast Summary

    SciTech Connect (OSTI)

    Valero, O.J.; Blackburn, C.L. [Westinghouse Hanford Co., Richland, WA (United States); Kaae, P.S.; Armacost, L.L.; Garrett, S.M.K. [Pacific Northwest Lab., Richland, WA (United States)

    1993-08-01

    This report, which updates WHC-EP-0567, 1992 Solid Waste Reference Forecast Summary, (WHC 1992) forecasts the volumes of solid wastes to be generated or received at the US Department of Energy Hanford Site during the 30-year period from FY 1993 through FY 2022. The data used in this document were collected from Westinghouse Hanford Company forecasts as well as from surveys of waste generators at other US Department of Energy sites who are now shipping or plan to ship solid wastes to the Hanford Site for disposal. These wastes include low-level and low-level mixed waste, transuranic and transuranic mixed waste, and nonradioactive hazardous waste.

  7. A New Solar Irradiance Reference Spectrum

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach HomeA Better Anode Design to Improve Lithium-Ion Batteries PrintA New Solar Irradiance Reference Spectrum

  8. Technical Reference for Hydrogen Compatibility of Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservationBio-Inspired Solar Fuel ProductionRecoverable15/2008 Technical Reference on

  9. Technical Reference on Hydrogen Compatibility of Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservationBio-Inspired Solar Fuel ProductionRecoverable15/2008 Technical Reference onType

  10. Technical Reference on Hydrogen Compatibility of Materials

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservationBio-Inspired Solar Fuel ProductionRecoverable15/2008 Technical Reference onType1

  11. Administrator References and Logins | Advanced Photon Source

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room News Publications Traditional Knowledge KiosksAboutHelp & Reference Users Home Contacts

  12. Property:Reference material | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmental Jump to:EA EIS Report Url Jump to:Programmable WavemakingPurchasersReference

  13. Commercial Reference Buildings | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTIONRobertsdale, Alabama (Utility Company)| Open EnergyColoradoBiomass EnergyCity,Commercial Reference

  14. Cooling Tower Operation in the Hot and Humid Climates of Arid Zones 

    E-Print Network [OSTI]

    Al-Bassam, E.; Maheshwari, G. P.; Sebzali, M.

    2000-01-01

    Air-conditioning (A/C) in Kuwait is a necessity for comfortable living as the summer is extremely hot. Dry weather for most of the summer months reflects the effectiveness of using water-cooled (WC) systems. Cooling towers (C/Ts) at a Ministry...

  15. Reference worldwide model for antineutrinos from reactors

    E-Print Network [OSTI]

    Marica Baldoncini; Ivan Callegari; Giovanni Fiorentini; Fabio Mantovani; Barbara Ricci; Virginia Strati; Gerti Xhixha

    2015-02-16

    Antineutrinos produced at nuclear reactors constitute a severe source of background for the detection of geoneutrinos, which bring to the Earth's surface information about natural radioactivity in the whole planet. In this framework we provide a reference worldwide model for antineutrinos from reactors, in view of reactors operational records yearly published by the International Atomic Energy Agency (IAEA). We evaluate the expected signal from commercial reactors for ongoing (KamLAND and Borexino), planned (SNO+) and proposed (Juno, RENO-50, LENA and Hanohano) experimental sites. Uncertainties related to reactor antineutrino production, propagation and detection processes are estimated using a Monte Carlo based approach, which provides an overall site dependent uncertainty on the signal in the geoneutrino energy window on the order of 3%. We also implement the off-equilibrium correction to the reference reactor spectra associated with the long-lived isotopes and we estimate a 2.4% increase of the unoscillated event rate in the geoneutrino energy window due to the storage of spent nuclear fuels in the cooling pools. We predict that the research reactors contribute to less than 0.2% to the commercial reactor signal in the investigated 14 sites. We perform a multitemporal analysis of the expected reactor signal over a time lapse of 10 years using reactor operational records collected in a comprehensive database published at www.fe.infn.it/antineutrino.

  16. Preview Draft References for Modeling the Environment

    E-Print Network [OSTI]

    Ford, Andrew

    River, NJ, Prentice Hall. Claussen, M and multiple co-autors. 2000. Earth system models of intermediate

  17. Quick Reference Guide to Campus Emergencies

    E-Print Network [OSTI]

    rdwright

    2011-08-10

    Jun 2, 2010 ... ... the Emergency Notification Group. • Boiler TV: The Boiler Television. Emergency Alerting System may also broadcast emergency information.

  18. Evaluation of Vegetative Roofs' Performance on Energy Consumption in Hot and Humid Climates 

    E-Print Network [OSTI]

    Anderson, J.; Azarbayjani, M.

    2008-01-01

    policy- making. LEED standards evaluate buildings on a point system that considers site development, material selection, energy efficiency, and indoor environmental quality. Vegetative roofs qualify for up to 3 points in LEED as ?potential... technologies and strategies? under the storm water management and heat island effect categories. A vegetative roof may also accumulate points indirectly under the categories on energy efficiency and water efficient landscaping. (USGBC, 2002) Today...

  19. ARM Surface Meteorology Systems Instrument Handbook

    SciTech Connect (OSTI)

    Ritsche, MT

    2011-03-08

    The ARM Surface Meteorology Systems consist mainly of conventional in situ sensors that obtain a defined “core” set of measurements. The core set of measurements is: Barometric Pressure (kPa), Temperature (°C), Relative Humidity (%), Arithmetic-Averaged Wind Speed (m/s), Vector-Averaged Wind Speed (m/s), and Vector-Averaged Wind Direction (deg).

  20. Supplementary Figure 1| Neutron diffraction data at 86 % relative humidity. a) Schematic representation of neutron diffraction geometry for -2 scans. Diffraction data are obtained

    E-Print Network [OSTI]

    White, Stephen

    distributions of lipid and protein under varying levels of hydration. Predicted neutron scattering profiles as number density profiles weighted by the neutron scattering lengths of individual atoms, then symmetrizedSupplementary Figure 1| Neutron diffraction data at 86 % relative humidity. a) Schematic

  1. Analysis of Energy, Environmental and Life Cycle Cost Reduction Potential of Ground Source Heat Pump (GSHP) in Hot and Humid Climate

    Broader source: Energy.gov [DOE]

    Project objectives: Gather and analyze independently the available technical, cost, financial incentive data on installed GSHP/HGSHP applications in residential, commercial and schools in hot and humid climate regions, and develop a calibrated baseline and performance period model of new construction and retrofitted buildings in conjunction with the energy simulation program.

  2. Evapotranspiration of Cool-Season Turfgrasses in the Humid Northeast' L. J. Aronson, A. J. Gold, R. J. Hull, and J. L. Cisar2

    E-Print Network [OSTI]

    Gold, Art

    Evapotranspiration of Cool-Season Turfgrasses in the Humid Northeast' L. J. Aronson, A. J. Gold, R that will lower water requirements as competition for water use increases. Transpiration accounts for most of the water lost from a dense turfgrass canopy (Beard, 1973). It has been established that transpiration rate

  3. A FULLY COUPLED THERMO-HYDRO MECHANICAL ANALYSIS OF THE IMPACT OF TEMPERATURE AND HUMIDITY VARIATION ON THE STATE OF HISTORICAL STONE

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    A FULLY COUPLED THERMO-HYDRO MECHANICAL ANALYSIS OF THE IMPACT OF TEMPERATURE AND HUMIDITY Keywords: Thermo-hydro-mechanical coupling, modelling, inverse problem, tuffeau, monument, in situ measures initiation and growth due to the variation of climate conditions; thermo-hydro-mechanical incompatibility

  4. Building America Best Practices Series: Volume 1; Builders and Buyers Handbook for Improving New Home Efficiency, Comfort, and Durability in the Hot and Humid Climate

    SciTech Connect (OSTI)

    2004-12-01

    This Building America Best Practices guide book is a resource to help builders large and small build high-quality, energy-efficient homes that achieve 30% energy savings in space conditioning and water heating in the hot and humid climate.

  5. Forests, Water and People in the Humid Tropics, ed. M. Bonell and L.A. Bruijnzeel. Published by Cambridge University Press. UNESCO 2005

    E-Print Network [OSTI]

    Chappell, Nick A

    Forests, Water and People in the Humid Tropics, ed. M. Bonell and L.A. Bruijnzeel. Published Minimising the hydrological impact of forest harvesting in Malaysia's rain forests to the use of tracked vehicles ('skidders') and haulage lorries, such extraction is slow and costly

  6. Strain-induced kinetics of intergrain defects as the mechanism of slow dynamics in the nonlinear resonant response of humid sandstone bars

    E-Print Network [OSTI]

    resonant response of humid sandstone bars Oleksiy O. Vakhnenko,1 Vyacheslav O. Vakhnenko,2 Thomas J of sandstone bars, namely, (i) hysteretic behavior of a resonance curve on both its upward and downward slopes strain. In order to reproduce the highly nonlinear elastic features of sandstone grained structure

  7. Environmental Management System Plan

    E-Print Network [OSTI]

    Fox, Robert

    2009-01-01

    OIA/OCA/assurance-sys/IA/index.html Management Program, R-3 • Environmental Management System Plan References 30.targets, and Environmental Management Programs 6. Structure

  8. ACAA fly ash basics: quick reference card

    SciTech Connect (OSTI)

    2006-07-01

    Fly ash is a fine powdery material created when coal is burned to generate electricity. Before escaping into the environment via the utility stacks, the ash is collected and may be stored for beneficial uses or disposed of, if necessary. The use of fly ash provides environmental benefits, such as the conservation of natural resources, the reduction of greenhouse gas emissions and eliminating the needed for ash disposal in landfills. It is also a valuable mineral resource that is used in construction and manufacturing. Fly ash is used in the production of Portland cement, concrete, mortars and stuccos, manufactured aggregates along with various agricultural applications. As mineral filler, fly ash can be used for paints, shingles, carpet backing, plastics, metal castings and other purposes. This quick reference card is intended to provide the reader basic source, identification and composition, information specifically related to fly ash.

  9. Webinar October 13: Reference Designs for Hydrogen Fueling Stations...

    Broader source: Energy.gov (indexed) [DOE]

    titled "Reference Designs for Hydrogen Fueling Stations" on Tuesday, October 13, from 12 to 1 p.m. Eastern Daylight Time (EDT). The goal of the H2FIRST Reference Station Design...

  10. United States Department of the Interior - RM-53 - Reference...

    Open Energy Info (EERE)

    search OpenEI Reference LibraryAdd to library PermittingRegulatory Guidance - GuideHandbook: United States Department of the Interior - RM-53 - Reference Manual - Special Park...

  11. ORNL/TM-2012/501 Small Hydropower Cost Reference

    E-Print Network [OSTI]

    Post, Wilfred M.

    ORNL/TM-2012/501 Small Hydropower Cost Reference Model October 2012 Prepared by Qin Fen (Katherine Government or any agency thereof. #12;ORNL/TM-2012/501 Small Hydropower Cost Reference Model Final Project

  12. Reference Buildings by Climate Zone and Representative City:...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    hicago-oharenew2004v1-47-2.zip More Documents & Publications Reference Buildings by Climate Zone and Representative City: 5A Chicago, Illinois Reference Buildings by Climate...

  13. H2FIRST Reference Station Design Task: Project Deliverable 2...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Reference Station Design Task: Project Deliverable 2-2 H2FIRST Reference Station Design Task: Project Deliverable 2-2 This H2FIRST project report, published in April 2015, presents...

  14. Air Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference

    E-Print Network [OSTI]

    Wechsler, Risa H.

    Air Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference Department: Chemical permit regulations are designed to track, record, and control air pollutants belonging to several on chemical classifications. This reference outlines major categories of air pollutants found at SLAC

  15. Bay Ridge Gardens - Mixed-Humid Affordable Multifamily Housing Deep Energy Retrofit

    SciTech Connect (OSTI)

    Lyons, J.; Moore, M.; Thompson, M.

    2013-08-01

    Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place DER at the Bay Ridge multifamily (MF) development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a 'base scope' retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a 'DER scope' which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. The base scope was applied to the entire apartment complex, except for one 12-unit building which underwent the DER scope. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

  16. Bay Ridge Gardens - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit

    SciTech Connect (OSTI)

    Lyons, James; Moore, Mike; Thompson, Margo

    2013-08-01

    Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost effectiveness of efficiency upgrade measures for a tenant-in-place deep energy retrofit (DER) at the Bay Ridge multifamily development in Annapolis, Maryland. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a "base scope" retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a "DER scope" which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

  17. High sensitivity optomechanical reference accelerometer over 10 kHz

    E-Print Network [OSTI]

    Felipe Guzman Cervantes; Lee Kumanchik; Jon Pratt; Jacob Taylor

    2014-08-28

    We present an optically-detected mechanical accelerometer that achieves a sensitivity of 100 ng/rtHz over a bandwidth of 10kHz and is traceable. We have incorporated a Fabry-Perot fiber-optic micro-cavity that is currently capable of measuring the test-mass displacement with sensitivities of 200 am/rtHz, and whose length determination enables traceability to the International System of Units (SI). The compact size and high mQ-product achieved combined with the high sensitivity and simplicity of the implemented optical detection scheme highlight our device and this category of accelerometers, outlining a path for high sensitivity reference acceleration measurements and observations in seismology and gravimetry.

  18. RECENT REFERENCES: JULY 1, 2006 TO SEPTEMBER 30, 2006

    SciTech Connect (OSTI)

    WINCHELL, D.F.

    2006-09-30

    This document lists experimental references added to Nuclear Science References (NSR) during the period July 1, 2006 to September 30, 2006. The first section lists keynumbers and keywords sorted by mass and nuclide. The second section lists all references, ordered by keynumber.

  19. RECENT REFERENCES: JANUARY 1, 2005 TO DECEMBER 31, 2005

    SciTech Connect (OSTI)

    WINCHELL, D.F.

    2005-12-31

    This document lists experimental references added to Nuclear Science References (NSR) during the period January 1, 2005 to December 31, 2005. The first section lists keynumbers and keywords sorted by mass and nuclide. The second section lists all references, ordered by keynumber.

  20. RECENT REFERENCES: APRIL 1, 2006 TO JUNE 30, 2006

    SciTech Connect (OSTI)

    WINCHELL, D.F.

    2006-06-30

    This document lists experimental references added to Nuclear Science References (NSR) during the period April 1, 2006 to June 30, 2006. The first section lists keynumbers and keywords sorted by mass and nuclide. The second section lists all references, ordered by keynumber.

  1. RECENT REFERENCES: OCTOBER 1, 2005 TO DECEMBER 31, 2005

    SciTech Connect (OSTI)

    WINCHELL, D.F.

    2005-12-31

    This document lists experimental references added to Nuclear Science References (NSR) during the period October 1, 2005 to December 31, 2005. The first section lists keynumbers and keywords sorted by mass and nuclide. The second section lists all references, ordered by keynumber.

  2. On the Intrinsic Locality Properties of Web Reference Streams

    E-Print Network [OSTI]

    Keinan, Alon

    On the Intrinsic Locality Properties of Web Reference Streams Rodrigo Fonseca Virg´ilio Almeida in the study of Web reference streams: sequences of requests for Web objects. In particular, many studies have into the nature of reference stream transformations in the Web. I. INTRODUCTION Considerable effort has gone

  3. Experimental Studies of the Tribological Behavior of Microelectromechanical Systems

    E-Print Network [OSTI]

    Xiang, Hua

    2013-01-01

    3.1 Introduction Microelectromechanical systems (MEMS)Chair Microelectromechanical systems (MEMS) are used in aSystems Microelectromechanical system (MEMS) refers to

  4. Distributed Mathematica { User and Reference Cleopatra Pau

    E-Print Network [OSTI]

    File . . . . . . . . . . . . . . . . . . . . . . . . . 16 LabelD: Create a Label . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4 System Con#12;guration 16 2 #12; 1 Introduction This report and the package described of the Distributed Mathematica package, that is a system for writing distributed applications in Mathematica [2

  5. Previous Up Next Article From References: 2

    E-Print Network [OSTI]

    Froyland, Gary

    maps, Communications in Mathematical Physics, 156 (1993), 355­385. MR1233850 (94g:58172) 4. Michael.-P. Eckmann, Liapunov multipliers and decay of correlations in dynamical systems, Journal of Statistical theory, analysis, and efficient simulation of dynamical systems," pages 145­174. Springer, Berlin, 2001

  6. Reference material manufacture and certification for the AVNG

    SciTech Connect (OSTI)

    Hauck, Danielle K; Mac Arthur, Duncan; Thron, Jonathan L; Livke, Alexander; Kondratov, Sergey; Razinkov, Sergey

    2010-01-01

    Testing and demonstration of any radiation measurement system requires the use of appropriate radioactive sources. The AVNG implementation that we describe is an attribute measurement system built by RFNC - VNIIEF in Sarov, Russia. The AVNG detects neutron and gamma radiation signatures and displays the three unclassified attributes of 'plutonium presence,' 'plutonium mass > 2 kg,' and 'plutonium isotopic ratio ({sup 240}Pu to {sup 239}Pu) < 0.1.' The AVNG was tested using a number of reference material (RM) sources with masses and isotopic ratios above and below these thresholds. The AVNG was demonstrated in June 2009 using several of these sources in addition to detector calibration sources. Since the AVNG was designed to measure multi-kg plutonium sources, the RM was manufactured specifically for use with this system. In addition, the RM was used to test the thresholds in the AVNG, so the size and composition of each RM was certified prior to use. In this presentation, we will describe the various steps in the manufacture and certification of these RM sources.

  7. Geographic Information System At International Geothermal Area...

    Open Energy Info (EERE)

    Information Systems- Tools For Geotherm Exploration, Tracers Data Analysis, And Enhanced Data Distribution, Visualization, And Management Additional References Retrieved from...

  8. Effect of deposition times on structure of Ga-doped ZnO thin films as humidity sensor

    SciTech Connect (OSTI)

    Khalid, Faridzatul Shahira; Awang, Rozidawati [School of Applied Physics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia)

    2014-09-03

    Gallium doped zinc oxide (GZO) has good electrical property. It is widely used as transparent electrode in photovoltaic devices, and sensing element in gas and pressure sensors. GZO thin film was prepared using magnetron sputtering. Film deposition times were set at 10, 15, 20, 25 and 30 minutes to get samples of different thickness. X-ray diffraction (XRD) was used to determine the structure of GZO thin films. Structure for GZO thin film is hexagonal wurtzite structure. Morphology and thickness of GZO thin films was observed from FESEM micrographs. Grain size and thickness of thin films improved with increasing deposition times. However, increasing the thickness of thin films occur below 25 minutes only. Electrical properties of GZO thin films were studied using a four-point probe technique. The changes in the structure of the thin films lead to the changed of their electrical properties resulting in the reduction of the film resistance. These thin films properties significantly implying the potential application of the sample as a humidity sensor.

  9. Assessing health impacts in complex eco-epidemiological settings in the humid tropics: Modular baseline health surveys

    SciTech Connect (OSTI)

    Winkler, Mirko S.; Divall, Mark J.; Krieger, Gary R.; Schmidlin, Sandro; Magassouba, Mohamed L.; Knoblauch, Astrid M.; Singer, Burton H.; Utzinger, Juerg

    2012-02-15

    The quantitative assessment of health impacts has been identified as a crucial feature for realising the full potential of health impact assessment (HIA). In settings where demographic and health data are notoriously scarce, but there is a broad range of ascertainable ecological, environmental, epidemiological and socioeconomic information, a diverse toolkit of data collection strategies becomes relevant for the mainly small-area impacts of interest. We present a modular, cross-sectional baseline health survey study design, which has been developed for HIA of industrial development projects in the humid tropics. The modular nature of our toolkit allows our methodology to be readily adapted to the prevailing eco-epidemiological characteristics of a given project setting. Central to our design is a broad set of key performance indicators, covering a multiplicity of health outcomes and determinants at different levels and scales. We present experience and key findings from our modular baseline health survey methodology employed in 14 selected sentinel sites within an iron ore mining project in the Republic of Guinea. We argue that our methodology is a generic example of rapid evidence assembly in difficult-to-reach localities, where improvement of the predictive validity of the assessment and establishment of a benchmark for longitudinal monitoring of project impacts and mitigation efforts is needed.

  10. FDL: A Prototype Formal Digital Library Description and Draft Reference Manual

    E-Print Network [OSTI]

    Kreitz, Christoph

    FDL: A Prototype Formal Digital Library ­ Description and Draft Reference Manual ­ Stuart Allen Library (FDL). We designed the system and assembled the prototype as part of a research project sponsored by the Office of Naval Research entitled Building Interactive Digital Libraries of Formal Algorithmic Knowledge

  11. Reference History, Page Size, and Migration Daemons in Local/Remote Architectures *

    E-Print Network [OSTI]

    Holliday, Mark A.

    Reference History, Page Size, and Migration Daemons in Local/Remote Architectures * Mark A multiprocessors. We consider the case where the operating system has primary responsibility and uses page migration as its main tool. We identify some of the key issues with respect to architectural sup- port

  12. A Reference-Frame for Installing the Student's Computer to Access a Virtual Medicine University

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    the setup - system and the reference-frame. Services concerning the management of the student' computer management (especially confidential issues), its installation and its testing have been enlightened. Those. De plus, ce référentiel est très utile pour un administrateur de site universitaire ou hospitalier

  13. Switch-reference and the Indentification of Small Pro in Hidatsa

    E-Print Network [OSTI]

    Boyle, John P.

    1999-01-01

    The purpose of this paper is to explore the Hidatsa switch-reference (SR) system and determine the relationship it has with the null category pro. I focus on two morphemes -nk (SS) and -nuk (DS) whose roles have been misidentified (Robinett 1955...

  14. REFERENCES 21 [15] H. M. Mabie and C. F. Reinholtz. Mechanisms and Dynamics of Machinery,

    E-Print Network [OSTI]

    Subramanian, Devika

    REFERENCES 21 [15] H. M. Mabie and C. F. Reinholtz. Mechanisms and Dynamics of Machinery, 4th edition. John Wiley and Sons, 1987. [16] H.M. Paynter. Analysis and Design of Engineering Systems. MIT Press, 1961. [17] M.M. Rueleaux. The Kinematics of Machinery. MacMillan & Co., 1876. Translated by Alex

  15. Reference Design? | OpenEI Community

    Open Energy Info (EERE)

    Well, there are a some decisions to make when setting up DataBus: First, define terms: A "sensor system" where Assets generate Readings from Attributes. For example, a power meter...

  16. International linear collider reference design report

    SciTech Connect (OSTI)

    Aarons, G.

    2007-06-22

    The International Linear Collider will give physicists a new cosmic doorway to explore energy regimes beyond the reach of today's accelerators. A proposed electron-positron collider, the ILC will complement the Large Hadron Collider, a proton-proton collider at the European Center for Nuclear Research (CERN) in Geneva, Switzerland, together unlocking some of the deepest mysteries in the universe. With LHC discoveries pointing the way, the ILC -- a true precision machine -- will provide the missing pieces of the puzzle. Consisting of two linear accelerators that face each other, the ILC will hurl some 10 billion electrons and their anti-particles, positrons, toward each other at nearly the speed of light. Superconducting accelerator cavities operating at temperatures near absolute zero give the particles more and more energy until they smash in a blazing crossfire at the centre of the machine. Stretching approximately 35 kilometres in length, the beams collide 14,000 times every second at extremely high energies -- 500 billion-electron-volts (GeV). Each spectacular collision creates an array of new particles that could answer some of the most fundamental questions of all time. The current baseline design allows for an upgrade to a 50-kilometre, 1 trillion-electron-volt (TeV) machine during the second stage of the project. This reference design provides the first detailed technical snapshot of the proposed future electron-positron collider, defining in detail the technical parameters and components that make up each section of the 31-kilometer long accelerator. The report will guide the development of the worldwide R&D program, motivate international industrial studies and serve as the basis for the final engineering design needed to make an official project proposal later this decade.

  17. Particle rapidity distribution in proton-nucleus collisions using the proton-contributor reference frame

    E-Print Network [OSTI]

    Gines Martinez-Garcia

    2014-08-14

    I define the proton-contributor reference frame in proton nucleus (p--A) collisions as the center of mass of the system formed by the proton and the participant nucleons of the nucleus. Assuming that the rapidity distribution of produced particles is symmetric in the proton-contributor reference frame, several measurements in p-Pb collisions at $\\sqrt{s_{\\rm NN}} = 5.02 {\\rm TeV}$ can be described qualitatively. These include rapidity distributions of charged particles, $J/\\psi$ and Z bosons.

  18. Development of an LED reference light source for calibration of radiographic imaging detectors

    E-Print Network [OSTI]

    M. Weierganz; D. Bar; B. Bromberger; V. Dangendorf; G. Feldman; M. B. Goldberg; M. Lindemann; I. Mor; K. Tittelmeier; D. Vartsky

    2010-02-08

    A stable reference light source based on an LED (Light Emission Diode) is presented for stabilizing the conversion gain of the opto-electronic system of a gamma- and fast-neutron radiographic and tomographic imaging device. A constant fraction of the LED light is transported to the image plane of the camera and provides a stable reference exposure. This is used to normalize the images during off-line image processing. We have investigated parameters influencing the stability of LEDs and developed procedures and criteria to prepare and select LEDs suitable for delivering stable light outputs for several 100 h of operation.

  19. Cross-References Applications of Nanofluidics

    E-Print Network [OSTI]

    Zhigilei, Leonid V.

    coarse-grained representations of the mate- rial structure, with elementary units in the models designed; Dislocation dynamics; Kinetic Monte Carlo method; Mechanical properties of nanomaterials; Mesoscopic modeling systems with submicron thickness of the layers. Atomistic modeling is based on atoms as elementary units

  20. Electromagnetic Radiation REFERENCE: Remote Sensing of

    E-Print Network [OSTI]

    Gilbes, Fernando

    ;2 Electromagnetic Energy Interactions Energy recorded by remote sensing systems undergoes fundamental interactions that should be understood to properly interpret the remotely sensed data. For example, if the energy being nanosecond (10-9 s). The electromagnetic wave consists of two fluctuating fields--one electric and the other