Powered by Deep Web Technologies
Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

High resolution time interval meter  

DOE Patents [OSTI]

Method and apparatus are provided for measuring the time interval between two events to a higher resolution than reliability available from conventional circuits and component. An internal clock pulse is provided at a frequency compatible with conventional component operating frequencies for reliable operation. Lumped constant delay circuits are provided for generating outputs at delay intervals corresponding to the desired high resolution. An initiation START pulse is input to generate first high resolution data. A termination STOP pulse is input to generate second high resolution data. Internal counters count at the low frequency internal clock pulse rate between the START and STOP pulses. The first and second high resolution data are logically combined to directly provide high resolution data to one counter and correct the count in the low resolution counter to obtain a high resolution time interval measurement.

Martin, A.D.

1986-05-09T23:59:59.000Z

2

Use of Utility Interval Meters in an Industrial Energy Audit  

E-Print Network [OSTI]

This paper describes a unique approach to an energy audit of a large tank farm. The audit was unusual in that it was located out-of-doors and the energy-using equipment was made up almost entirely of pumps. The auditors used the utility interval...

Wallace, M.

2007-01-01T23:59:59.000Z

3

Insights from Smart Meters: The Potential for Peak-Hour Savings from Behavior-Based Programs  

SciTech Connect (OSTI)

The rollout of smart meters in the last several years has opened up new forms of previously unavailable energy data. Many utilities are now able in real-time to capture granular, household level interval usage data at very high-frequency levels for a large proportion of their residential and small commercial customer population. This can be linked to other time and locationspecific information, providing vast, constantly growing streams of rich data (sometimes referred to by the recently popular buzz word, big data). Within the energy industry there is increasing interest in tapping into the opportunities that these data can provide. What can we do with all of these data? The richness and granularity of these data enable many types of creative and cutting-edge analytics. Technically sophisticated and rigorous statistical techniques can be used to pull interesting insights out of this highfrequency, human-focused data. We at LBNL are calling this behavior analytics. This kind of analytics has the potential to provide tremendous value to a wide range of energy programs. For example, highly disaggregated and heterogeneous information about actual energy use would allow energy efficiency (EE) and/or demand response (DR) program implementers to target specific programs to specific households; would enable evaluation, measurement and verification (EM&V) of energy efficiency programs to be performed on a much shorter time horizon than was previously possible; and would provide better insights in to the energy and peak hour savings associated with specifics types of EE and DR programs (e.g., behavior-based (BB) programs). In this series, Insights from Smart Meters, we will present concrete, illustrative examples of the type of value that insights from behavior analytics of these data can provide (as well as pointing out its limitations). We will supply several types of key findings, including: Novel results, which answer questions the industry previously was unable to answer; Proof-of-concept analytics tools that can be adapted and used by others; and Guidelines and protocols that summarize analytical best practices. This report focuses on one example of the kind of value that analysis of this data can provide: insights into whether behavior-based (BB) efficiency programs have the potential to provide peak-hour energy savings.

Todd, Annika; Perry, Michael; Smith, Brian; Sullivan, Michael; Cappers, Peter; Goldman, Charles

2014-03-25T23:59:59.000Z

4

Insights from Smart Meters: The Potential for Peak-Hour Savings from Behavior-Based Programs  

E-Print Network [OSTI]

top graph) as a percent of the total average energy usage ofgraph) as a percentage of each hours average energy usagegraph: first, kWh savings; second, normalized savings as a percent of the total average energy usage

Todd, Annika

2014-01-01T23:59:59.000Z

5

BPA Metering Services Editing and Estimating Procedures  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Editing and Estimating Interval Data 1. Introduction This section defines the meter interval data editing and estimation techniques performed by BPA's Metering Services...

6

installed on all three resoitors. Between February 27 and necessary at a 1.2 m (4.0 it) depth for a reason-and May 15, 1980 all the time metern, the house watt-ably sized earth coil in this location.hour meter, and the indoor temperature as measured by Th  

E-Print Network [OSTI]

.hour meter, and the indoor temperature as measured by The design procedure for the length of the eartha glass. Thea the CROC5 heating seson werelyfth day from the running time meter. heat input QH(i) ist The second at by using a differnt set of "xperimental measurements (air handler time meter for B1, and house Q (i) " B

Oak Ridge National Laboratory

7

Metering Systems  

Broader source: Energy.gov [DOE]

A variety of metering systems are currently on the market for Federal facility implementation. The information below outlines common metering system capabilities and common metering system components.

8

Federal Metering Requirements  

Broader source: Energy.gov (indexed) [DOE]

Metering Requirements Metering Requirements FUPWG - May 23, 2013 Brad Gustafson Federal Energy Management Program 2 42 USC 8253 - ENERGY MANAGEMENT REQUIREMENT (e) Metering By October 1, 2012, in accordance with guidelines established by the Secretary under paragraph (2), all Federal buildings shall, for the purposes of efficient use of energy and reduction in the cost of electricity used in such buildings, be metered. Each agency shall use, to the maximum extent practicable, advanced meters or advanced metering devices that provide data at least daily and that measure at least hourly consumption of electricity in the Federal buildings of the agency. Not later than October 1, 2016, each agency shall provide for equivalent metering of natural gas and steam, in accordance with guidelines established by the Secretary

9

Metering Process  

Broader source: Energy.gov [DOE]

Developing and implementing a metering plan is highly dependent on the individual facility's needs, mission, metering equipment, and available infrastructure. One size does not fit all.

10

Utility Metering - AGL Resources  

Broader source: Energy.gov (indexed) [DOE]

AGL Resources AGL Resources Mike Ellis Director, AGL Energy Services Federal Utility Partnership Working Group Spring 2013 - May 22-23 San Francisco, CA Hosted by: Pacific Gas and Electric Company  Multiple LDCs with legacy metering equipment  Several use Itron 100G technology ◦ Mobile, once-a-month data collection ◦ Meter can store interval data for >30 days ◦ Meter technology could be leverage on fixed-base network, however there are no current plans for upgrade  Technology for capturing interval data is installed on case by case basis ◦ Customers on Interruptible Rate ◦ Large users  Electronic corrector installed on the meter ◦ Pressure and Temperature compensation  Typically data is retrieved once a day ◦ Transmission frequency impacts battery life

11

Net Metering  

Broader source: Energy.gov [DOE]

In October 2009, the Regulatory Commission of Alaska (RCA) approved net metering regulations. These rules were finalized and approved by the lieutenant governor in January 2010 and became...

12

Net Metering  

Broader source: Energy.gov [DOE]

North Dakota's net-metering policy, adopted in 1991 by the state Public Service Commission (PSC), applies to renewable-energy systems and combined heat and power (CHP) systems up to 100 kilowatts ...

13

Net Metering  

Broader source: Energy.gov [DOE]

[http://nebraskalegislature.gov/FloorDocs/101/PDF/Final/LB436.pdf LB 436], signed in May 2009, established statewide net metering rules for all electric utilities in Nebraska. The rules apply to...

14

Net Metering  

Broader source: Energy.gov [DOE]

Nevada's original net-metering law for renewable-energy systems was enacted in 1997 and amended in 2001, 2003, 2005 and 2007. Systems up to one megawatt (MW) in capacity that generate electricity...

15

Saturation meter  

DOE Patents [OSTI]

A saturation meter for use in a pressurized water reactor plant comprising a differential pressure transducer having a first and second pressure sensing means and an alarm. The alarm is connected to the transducer and is preset to activate at a level of saturation prior to the formation of a steam void in the reactor vessel.

Gregurech, S.

1984-08-01T23:59:59.000Z

16

LADWP - Net Metering (California) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering (California) Net Metering (California) LADWP - Net Metering (California) < Back Eligibility Agricultural Commercial General Public/Consumer Industrial Residential Savings Category Solar Buying & Making Electricity Wind Program Info State California Program Type Net Metering Provider Los Angeles Department of Water and Power LADWP allows its customers to net meter their photovoltaic (PV), wind, and hybrid systems with a capacity of not more than one megawatt. LADWP will provide the necessary metering equipment unless an installation requires atypical metering equipment. In these cases the customer must cover the additional metering expenses. The customer must also pay any related interconnection fees. Excess kilowatt-hours (kWh) generated by the customer's system will be

17

Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Program Areas » Operations & Maintenance » Metering Program Areas » Operations & Maintenance » Metering Metering October 7, 2013 - 9:21am Addthis Historically, the Federal sector has lagged in metering applications. It is not uncommon to find one meter serving hundreds of Federal facilities. These master meters make it very difficult to manage energy use and are a primary driver for Federal metering requirements. To help Federal agencies meet these requirements, this section outlines strategies and resources surrounding metering best practices, including: Metering Systems: Overview of metering system capabilities and functionality as well as common components across various metering systems Metering Approaches: Description of the four primary approaches to metering, including required equipment common for each approach

18

Metering | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

the federal sector has lagged in metering applications. It is not uncommon to find one meter serving hundreds of federal facilities. These master meters make it very difficult to...

19

Discussion the Traceability of Quantity Value of Digital Watthour Meter  

Science Journals Connector (OSTI)

To resolve the traceability of quantity value and calibration of digital watt-hour meter, in this paper introduced working principium of digital electric power metering system briefly, and analyzed the main origin of error from the theory of digital watt-hour meter and its calibration device. This paper also proposed new verification method of digital watt-hour meter calibration device and project of digital watt-hour meter traceability of quantity value. The method is used in digital signal generator calibration. The traceability project is traceability to the national primary standard which is corresponding to the device using in the method. The project in this paper, which is figure out verification and traceability of quantity value from main origin of error, provides a reasonable approach to traceability of digital watt-hour meter and a useful reference to decriminalization of digital metrology. Meantime, the scheme provides strong technical support for construction of digital transformer substation and Smart Strong Grid.

Meng Xiangfu; Liu Yuchao; Wang Yuhua

2012-01-01T23:59:59.000Z

20

Western Meter Policy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

WESTERN AREA POWER ADMINISTRATION Meter Policy November 22, 2013 Western Area Power Administration Meter Policy Version: Final 11222013 2 | P a g e Table of Contents 1. Purpose...

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

SRP - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

SRP - Net Metering SRP - Net Metering SRP - Net Metering < Back Eligibility Commercial Residential Savings Category Buying & Making Electricity Solar Wind Program Info State Arizona Program Type Net Metering Provider SRP Salt River Project (SRP) modified an existing net-metering program for residential and commercial customers in November 2013. Net metering is now available to customers who generate electricity using photovoltaic (PV), geothermal, or wind systems up to 300 kilowatts (kW) in AC peak capacity. The kilowatt-hours (kWh) delivered to SRP are subtracted from the kWh delivered from SRP for each billing cycle. If the kWh calculation is net positive for the billing cycle, SRP will bill the net kWh to the customer under the applicable price plan, Standard Price Plan E-21, E-23, E-26,

22

Propeller Flow Meter  

E-Print Network [OSTI]

Propeller flow meters are commonly used to measure water flow rate. They can also be used to estimate irrigation water use. This publication explains how to select, install, read and maintain propeller flow meters....

Enciso, Juan; Santistevan, Dean; Hla, Aung K.

2007-10-01T23:59:59.000Z

23

Economics of Energy Metering  

E-Print Network [OSTI]

history of industrial usage and their mechanical simplicity. The Flow Technology Group divided orifice meters into three basic types -- Class A, B, and C. Class A meters are the ultimate current technology can provide. Their overall accuracy is ~l... cost for a Class A orifice is $45,000, excluding the computer cost. Class B meters have an accuracy of +2%. The transmitter analog outputs are usually recorded on charts. These meters are used for utilities accounting and non critical production...

Duncan, J. D.

1979-01-01T23:59:59.000Z

24

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Residential Residential Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Wyoming Program Type Net Metering Provider Wyoming Public Service Commission Wyoming enacted legislation in February 2001 that established statewide net metering. The law applies to investor-owned utilities, electric cooperatives and irrigation districts. Eligible technologies include solar, wind, biomass and hydropower systems up to 25 kilowatts (kW) in capacity. Systems must be intended primarily to offset part or all of the customer-generator's requirements for electricity. Net excess generation (NEG) is treated as a kilowatt-hour (kWh) credit or other compensation on the customer's following bill.* When an annual period ends, a utility will purchase unused credits at the utility's avoided-cost

25

Smart Meters Help Balance Energy Consumption at Solar Decathlon |  

Broader source: Energy.gov (indexed) [DOE]

Smart Meters Help Balance Energy Consumption at Solar Decathlon Smart Meters Help Balance Energy Consumption at Solar Decathlon Smart Meters Help Balance Energy Consumption at Solar Decathlon September 28, 2011 - 10:57am Addthis The Team Tidewater Virginia smart meter, as seen on opening day, indicates the team generated 5 kW hours of electricity in the first several hours of the competition. | Image courtesy of Lachlan Fletcher, Studio 18a The Team Tidewater Virginia smart meter, as seen on opening day, indicates the team generated 5 kW hours of electricity in the first several hours of the competition. | Image courtesy of Lachlan Fletcher, Studio 18a Liisa O'Neill Liisa O'Neill Former New Media Specialist, Office of Public Affairs Clouds, rain, thunderstorms... at Solar Decathlon Village? Oh my, you may say. But less-than-ideal weather conditions are no match for this year's

26

Smart Meters Help Balance Energy Consumption at Solar Decathlon |  

Broader source: Energy.gov (indexed) [DOE]

Smart Meters Help Balance Energy Consumption at Solar Decathlon Smart Meters Help Balance Energy Consumption at Solar Decathlon Smart Meters Help Balance Energy Consumption at Solar Decathlon September 28, 2011 - 10:57am Addthis The Team Tidewater Virginia smart meter, as seen on opening day, indicates the team generated 5 kW hours of electricity in the first several hours of the competition. | Image courtesy of Lachlan Fletcher, Studio 18a The Team Tidewater Virginia smart meter, as seen on opening day, indicates the team generated 5 kW hours of electricity in the first several hours of the competition. | Image courtesy of Lachlan Fletcher, Studio 18a Liisa O'Neill Liisa O'Neill Former New Media Specialist, Office of Public Affairs Clouds, rain, thunderstorms... at Solar Decathlon Village? Oh my, you may say. But less-than-ideal weather conditions are no match for this year's

27

EPAct 2005 Metering Guidance Overview  

Broader source: Energy.gov (indexed) [DOE]

EPAct 2005 Metering Guidance EPAct 2005 Metering Guidance Overview Dave Hunt Pacific Northwest National Laboratory Section 103 Requirements * What to meter - Building electric usage - All buildings * How to meter - Standard meters - Advanced meters * When - by 10/1/2012 FEMP's Response * Metering guidance document * Agency planning workshops * Metering training course * Metering Best Practices Guide (FY 2007) Important Dates * August 3, 2006 - agency plans due * As determined by individual agencies - site metering plans * October 1, 2012 - compliance deadline Issues * Funding * Practicability * EPAct time-based rate schedule * Agency policies/guidance Potential Roles for Utilities * Guidance/updates on time-based pricing * Metering services * Finance installations * Other? Useful Documents

28

The Economic Value of PV and Net Metering to Residential Customers in California  

E-Print Network [OSTI]

metering than with a feed-in tariff where all PV generationnet metering, MPR- based feed-in tariff, hourly netting, and1) An MPR-based feed-in tariff, under which the customer is

Darghouth, Naim

2010-01-01T23:59:59.000Z

29

Federal Energy Management Program: Metering  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Metering Metering Historically, the Federal sector has lagged in metering applications. It is not uncommon to find one meter serving hundreds of Federal facilities. These master meters make it very difficult to manage energy use and are a primary driver for Federal metering requirements. To help Federal agencies meet these requirements, this section outlines strategies and resources surrounding metering best practices, including: Metering Systems: Overview of metering system capabilities and functionality as well as common components across various metering systems. Metering Approaches: Description of the four primary approaches to metering, including required equipment common for each approach. Metering Process: Outline of the five step process typically used to evaluate, design, install, and implement Federal metering programs.

30

Energy Metering Audit Procedure  

E-Print Network [OSTI]

Energy Meterilg Audtt Procedure Wiliam S Whitaker Engineering Specialist T X E INC. laPorte Texas INTROOUCI'ION This paper describes the recent audit of the utility distriooticn meters in a petrochanica1 plant. These meters measure the steam..., cx:ndensate, natural gas, water, nitrogen and air flCMS to the different process units within the plant. This audit started as an attellPt to resolve discrepan::ies between the 650 PSIG steam distriootion and supply meters. Theoretically the sum...

Whitaker, W. S.

31

Federal Energy Management Program: Metering  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Metering to Metering to someone by E-mail Share Federal Energy Management Program: Metering on Facebook Tweet about Federal Energy Management Program: Metering on Twitter Bookmark Federal Energy Management Program: Metering on Google Bookmark Federal Energy Management Program: Metering on Delicious Rank Federal Energy Management Program: Metering on Digg Find More places to share Federal Energy Management Program: Metering on AddThis.com... Sustainable Buildings & Campuses Operations & Maintenance Federal Requirements Program Management Commissioning Metering Systems Approaches Process Computerized Maintenance Management Systems Maintenance Types Major Equipment Types Resources Contacts Greenhouse Gases Water Efficiency Data Center Energy Efficiency Industrial Facilities

32

Meter Expansion Plan Existing Multi-Space Meter  

E-Print Network [OSTI]

Meter Expansion Plan 11 35 9 7 10 20 12 11 12 46 23 15 15 60 23 Existing Multi-Space Meter Split Regulations 136 New Multi-Space Meter Visitor Only New Multi-Space Meter Split Regulations KEY 97 Updated 7/8/13 11 5 #12;HAVE.HAVE. UNION DR. 1 2 3 4 5 New Multi-space Meter After: 5 Meter Spaces Regulations

Duchowski, Andrew T.

33

Meters | OpenEI  

Open Energy Info (EERE)

Meters Meters Dataset Summary Description The UK Department of Energy and Climate Change (DECC) releases annual statistics on domestic and non-domestic electricity and gas consumption (and number of meters) at the Middle Layer Super Output Authority (MLSOA) and Intermediate Geography Zone (IGZ) level (there are over 950 of these subregions throughout England, Scotland and Wales). Both MLSOAs (England and Wales) and IGZs (Scotland) include a minimum of approximately 2,000 households. The electricity consumption data data is split by ordinary electricity and economy7 electricity usage. Source UK Department of Energy and Climate Change (DECC) Date Released March 25th, 2010 (4 years ago) Date Updated Unknown Keywords Electricity Consumption gas Meters regional

34

WOOD STREET METERED LOT  

E-Print Network [OSTI]

LOT E1 LOT O WOOD STREET METERED LOT LOT W5 LOT C4 LOT B4 LOT L LOT M MARSHFIELDAVENUE PAULINASTREET Clinical Sciences Building UI Hospital Wood Street Station Clinical Sciences North Grand Grounds Garden

Dai, Yang

35

Net Metering Resources  

Broader source: Energy.gov [DOE]

State net metering policies allow customers to produce onsite electricity and sell excess generation to the utility at a set price, which creates an incentive for private investment in distributed...

36

NASA's Metering Plan  

Energy Savers [EERE]

4 May '06 Response to Response to EPAct EPAct * Agency-Wide (17 sites) * All Energy Utilities * Potable Water * E-Survey (all sites) * Physical Survey (3 sites) * Metering...

37

Ashland Electric- Net Metering  

Broader source: Energy.gov [DOE]

In 1996, Ashland adopted a net-metering program that includes simple interconnection guidelines. The program encourages the adoption of renewable-energy systems by committing the city to purchase,...

38

Advanced Metering Infrastructure  

SciTech Connect (OSTI)

The report provides an overview of the development of Advanced Metering Infrastructure (AMI). Metering has historically served as the cash register for the utility industry. It measured the amount of energy used and supported the billing of customers for that usage. However, utilities are starting to look at meters in a whole different way, viewing them as the point of contact with customers in supporting a number of operational imperatives. The combination of smart meters and advanced communications has opened up a variety of methods for utilities to reduce operating costs while offering new services to customers. A concise look is given at what's driving interest in AMI, the components of AMI, and the creation of a business case for AMI. Topics covered include: an overview of AMI including the history of metering and development of smart meters; a description of the key technologies involved in AMI; a description of key government initiatives to support AMI; an evaluation of the current market position of AMI; an analysis of business case development for AMI; and, profiles of 21 key AMI vendors.

NONE

2007-10-15T23:59:59.000Z

39

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Energy Sources Solar Home Weatherization Wind Program Info State Massachusetts Program Type Net Metering Provider Department of Public Utilities In Massachusetts, the state's investor-owned utilities must offer net metering. Municipal utilities are not obligated to offer net metering, but they may do so voluntarily. (There are no electric cooperatives in Massachusetts.) Class I, Class II, Class III net metering facilities In Massachusetts, there are several categories of net-metering facilities.

40

Neutron dose equivalent meter  

DOE Patents [OSTI]

A neutron dose equivalent detector for measuring neutron dose capable of accurately responding to neutron energies according to published fluence to dose curves. The neutron dose equivalent meter has an inner sphere of polyethylene, with a middle shell overlying the inner sphere, the middle shell comprising RTV.RTM. silicone (organosiloxane) loaded with boron. An outer shell overlies the middle shell and comprises polyethylene loaded with tungsten. The neutron dose equivalent meter defines a channel through the outer shell, the middle shell, and the inner sphere for accepting a neutron counter tube. The outer shell is loaded with tungsten to provide neutron generation, increasing the neutron dose equivalent meter's response sensitivity above 8 MeV.

Olsher, Richard H. (Los Alamos, NM); Hsu, Hsiao-Hua (Los Alamos, NM); Casson, William H. (Los Alamos, NM); Vasilik, Dennis G. (Los Alamos, NM); Kleck, Jeffrey H. (Menlo Park, CA); Beverding, Anthony (Foster City, CA)

1996-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Murray City Power - Net Metering Pilot Program | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Murray City Power - Net Metering Pilot Program Murray City Power - Net Metering Pilot Program Murray City Power - Net Metering Pilot Program < Back Eligibility Commercial General Public/Consumer Residential Savings Category Solar Buying & Making Electricity Home Weatherization Water Wind Program Info State Utah Program Type Net Metering Provider Murray City Power Under a pilot program, Murray City Power offers net metering to customers that generate electricity using photovoltaic (PV), wind-electric or hydroelectric systems with a maximum capacity of 10 kilowatts (kW).* The utility will install and maintain a revenue meter capable of registering the bi-directional flow of electricity at the customer's facility. Any customer net excess generation (NEG) is carried over to the customer's next bill as a kilowatt-hour credit. Each April, any remaining NEG credits are

42

Efficient Metering Schemes with Pricing  

E-Print Network [OSTI]

Efficient Metering Schemes with Pricing Barbara Masucci Dipartimento di Informatica ed Applicazioni and Pinkas [7] introduced metering schemes. They proposed metering schemes in which any server is able and proposed metering schemes with pricing. In their schemes any server is able to construct a proof which

Stinson, Douglas

43

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government General Public/Consumer Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Wind Solar Home Weatherization Program Info State Arkansas Program Type Net Metering Provider Arkansas Economic Development Commission In April 2001, Arkansas enacted legislation (HB 2325) directing the Arkansas Public Service Commission (PSC) to establish net-metering rules for certain renewable-energy systems.* The PSC approved final rules for net metering in July 2002. Subsequent legislation enacted in April 2007 (HB 2334) expanded the availability of net metering; increased the capacity

44

Elbow mass flow meter  

DOE Patents [OSTI]

Elbow mass flow meter. The present invention includes a combination of an elbow pressure drop generator and a shunt-type mass flow sensor for providing an output which gives the mass flow rate of a gas that is nearly independent of the density of the gas. For air, the output is also approximately independent of humidity.

McFarland, Andrew R. (College Station, TX); Rodgers, John C. (Santa Fe, NM); Ortiz, Carlos A. (Bryan, TX); Nelson, David C. (Santa Fe, NM)

1994-01-01T23:59:59.000Z

45

Federal Metering Requirements  

Broader source: Energy.gov [DOE]

Presentationgiven at the Spring 2013 Federal Utility Partnership Working Group (FUPWG) meetingcovers the 42 USC 8253 Energy Management Requirement; Executive Order 13514(g) High-Performance Sustainable Federal Buildings; federal metering needs, history, and status; and utility/agency opportunities.

46

Metering Systems | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Systems Systems Metering Systems October 7, 2013 - 9:23am Addthis A variety of metering systems are currently on the market for Federal facility implementation. The information below outlines common metering system capabilities and common metering system components. Metering System Capabilities The capabilities and functionality of metering systems vary depending on the individual metering system. The following are some of the more common features used by Federal facilities. Data Recording: Advanced meters can record total energy resource consumption in addition to enhanced functions like time-of-use, peak demand, load survey, and power outage. Electrical meters may also be able to record data points such as voltage, current, and power factor. Total Consumption: The most basic data function, total consumption records

47

Flow metering valve  

DOE Patents [OSTI]

An apparatus for metering fluids at high pressures of about 20,000 to 60,000 psi is disclosed. The apparatus includes first and second plates which are positioned adjacent each other to form a valve chamber. The plates are made of materials which have substantially equal elastic properties. One plate has a planar surface area, and the other a recessed surface area defined by periphery and central lips. When the two plates are positioned in adjacent contacting relationship, a valve chamber is formed between the planar surface area and the recessed surface area. Fluid is introduced into the chamber and exits therefrom when a deformation occurs at positions where they no longer form a valve seat. This permits the metering of fluids at high pressures and at slow variable rates. Fluid then exits from the chamber until an applied external force becomes large enough to bring the valve seats back into contact.

Blaedel, Kenneth L. (Dublin, CA)

1985-01-01T23:59:59.000Z

48

Flow metering valve  

DOE Patents [OSTI]

An apparatus for metering fluids at high pressures of about 20,000 to 60,000 psi is disclosed. The apparatus includes first and second plates which are positioned adjacent each other to form a valve chamber. The plates are made of materials which have substantially equal elastic properties. One plate has a planar surface area, and the other a recessed surface area defined by periphery and central lips. When the two plates are positioned in adjacent contacting relationship, a valve chamber is formed between the planar surface area and the recessed surface area. Fluid is introduced into the chamber and exits therefrom when a deformation occurs at positions where they no longer form a valve seat. This permits the metering of fluids at high pressures and at slow variable rates. Fluid then exits from the chamber until an applied external force becomes large enough to bring the valve seats back into contact.

Blaedel, K.L.

1983-11-03T23:59:59.000Z

49

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial Industrial Residential Fed. Government Institutional Local Government Multi-Family Residential Nonprofit Schools State Government Savings Category Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Solar Home Weatherization Wind Program Info State District of Columbia Program Type Net Metering Provider Washington State University Washington's net-metering law applies to systems up to 100 kilowatts (kW) in capacity that generate electricity using solar, wind, hydro, biogas from animal waste, or combined heat and power technologies (including fuel cells). All customer classes are eligible, and all utilities -- including municipal utilities and electric cooperatives -- must offer net metering.

50

A microwave impedance meter  

E-Print Network [OSTI]

A MICROWAVE IMPEDANCE METER A Thesis Virgil Layfaette 8oaz Submitted to the Graduate School of the Agricultural and Mechanical College oi' Texas in partial fulfillment of the requirements for the degree of MASTER OF SC I ENCE August 1 g61... and advice of Dr. J. P, German who suggested the research proj ct and rendered assistance when necessary. Further thanks are extended to the Electrical Engineering Faculty and Staff for their patience and suggestions, 1v CONTENTS LIST OF FIGURES...

Boaz, Virgil Layfaette

2012-06-07T23:59:59.000Z

51

How to Read Your Electric Meter | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Your Electric Meter Your Electric Meter How to Read Your Electric Meter July 2, 2012 - 8:21pm Addthis The difference between one month's reading and the next is the amount of energy units that have been used for that billing period. | Photo courtesy of Warren Gretz, NREL. The difference between one month's reading and the next is the amount of energy units that have been used for that billing period. | Photo courtesy of Warren Gretz, NREL. What are the key facts? The basic unit of measure of electric power is the Watt, and one thousand Watts are called a kilowatt. Your electric utility bills you by the kilowatt-hour -- the number of kilowatts you use per hour. When reading an electric meter, read and write down the numbers as shown on the dials from right to left. You may also wish to contact your local utility company for more

52

How to Read Your Electric Meter | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

How to Read Your Electric Meter How to Read Your Electric Meter How to Read Your Electric Meter July 2, 2012 - 8:21pm Addthis The difference between one month's reading and the next is the amount of energy units that have been used for that billing period. | Photo courtesy of Warren Gretz, NREL. The difference between one month's reading and the next is the amount of energy units that have been used for that billing period. | Photo courtesy of Warren Gretz, NREL. What are the key facts? The basic unit of measure of electric power is the Watt, and one thousand Watts are called a kilowatt. Your electric utility bills you by the kilowatt-hour -- the number of kilowatts you use per hour. When reading an electric meter, read and write down the numbers as shown on the dials from right to left.

53

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Solar Home Weatherization Wind Program Info State Vermont Program Type Net Metering Provider Vermont Department of Public Service NOTE: Legislation enacted in May 2012 (HB475) further amends Vermont's net metering policy. Vermont's original net-metering legislation was enacted in 1998, and the law has been expanded several times subsequently. Any electric customer in Vermont may net meter after obtaining a Certificate of Public Good from the Vermont Public Service Board (PSB). Solar net metered systems 10 kilowatts

54

Metering Systems | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

categories: electrical and flow-related. Electrical meters can track whole-building energy use (e.g., utility meters), sub-panel energy use (e.g., lighting), or a specific end...

55

Smart Meter Company Boosting Production, Workforce | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Smart Meter Company Boosting Production, Workforce Smart Meter Company Boosting Production, Workforce Smart Meter Company Boosting Production, Workforce September 30, 2010 - 10:53am Addthis Kevin Craft What does this mean for me? This South Carolina company is producing enough smart meters to reduce annual electricity use by approximately 1.7 million megawatt hours Smart meters provide detailed data on energy usage to both utilities and consumers and is a key component of the Smart Grid. In 2009, Itron Inc.'s manufacturing facility in West Union, South Carolina was the third largest industrial employer in Oconee County. Then, the company used a $5.2 million 48C Advanced Manufacturing Tax Credit awarded via the Recovery Act to re-equip the facility and hired 420 additional employees. "Improving our production capacity allowed us to hire more employees, and

56

Smart Meter Company Boosting Production, Workforce | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Smart Meter Company Boosting Production, Workforce Smart Meter Company Boosting Production, Workforce Smart Meter Company Boosting Production, Workforce September 30, 2010 - 10:53am Addthis Kevin Craft What does this mean for me? This South Carolina company is producing enough smart meters to reduce annual electricity use by approximately 1.7 million megawatt hours Smart meters provide detailed data on energy usage to both utilities and consumers and is a key component of the Smart Grid. In 2009, Itron Inc.'s manufacturing facility in West Union, South Carolina was the third largest industrial employer in Oconee County. Then, the company used a $5.2 million 48C Advanced Manufacturing Tax Credit awarded via the Recovery Act to re-equip the facility and hired 420 additional employees. "Improving our production capacity allowed us to hire more employees, and

57

DSW_RMR Meter Policy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

WESTERN AREA POWER ADMINISTRATION WESTERN AREA POWER ADMINISTRATION Metering Policy Desert Southwest and Rocky Mountain Regions August 08, 2012 Western Meter Policy DSW and RMR Regions Version 1.0 08/08/2012 2 | P a g e Contents 1. Purpose......................................................................................................................................4 2. Scope .........................................................................................................................................4 3. General Meter Policy Requirements ............................................................................................5 4. Western Owned Facilities ............................................................................................................... 6

58

Portable wastewater flow meter  

DOE Patents [OSTI]

A portable wastewater flow meter particularly adapted for temporary use at a single location in measuring the rate of liquid flow in a circular entrance conduit of a sewer manhole both under free flow and submerged, open channel conditions and under fill pipe, surcharged conditions, comprising an apparatus having a cylindrical external surface and an inner surface that constricts the flow through the apparatus in such a manner that a relationship exists between (1) the difference between the static pressure head of liquid flowing through the entrance of the apparatus and the static pressure head of liquid flowing through the constriction, and (2) the rate of liquid flow through the apparatus.

Hunter, Robert M. (320 S. Wilson Ave., Bozeman, MT 59715)

1999-02-02T23:59:59.000Z

59

Portable wastewater flow meter  

DOE Patents [OSTI]

A portable wastewater flow meter particularly adapted for temporary use at a single location in measuring the rate of liquid flow in a circular entrance conduit of a sewer manhole both under free flow and submerged, open channel conditions and under full pipe, surcharged conditions, comprising an apparatus having a cylindrical external surface and an inner surface that constricts the flow through the apparatus in such a manner that a relationship exists between (1) the difference between the static pressure head of liquid flowing through the entrance of the apparatus and the static pressure head of liquid flowing through the constriction, and (2) the rate of liquid flow through the apparatus.

Hunter, Robert M. (320 S. Wilson Ave., Bozeman, MT 59715)

1990-01-01T23:59:59.000Z

60

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Tribal Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State North Carolina Program Type Net Metering Provider North Carolina Utilities Commission The North Carolina Utilities Commission (NCUC) requires the state's three investor-owned utilities -- Duke Energy, Progress Energy and Dominion North Carolina Power -- to make net metering available to customers that own and operate systems that generate electricity using solar energy, wind energy, hydropower, ocean or wave energy, biomass resources, combined heat and

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Missouri Program Type Net Metering Provider Missouri Public Service Commission Missouri enacted legislation in June 2007 (S.B. 54)* requiring all electric utilities -- investor-owned utilities, municipal utilities and electric cooperatives -- to offer net metering to customers with systems up to 100 kilowatts (kW) in capacity that generate electricity using wind energy, solar-thermal energy, hydroelectric energy, photovoltaics (PV), fuel cells

62

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Solar Home Weatherization Water Wind Program Info State Maryland Program Type Net Metering Provider Maryland Public Service Commission Note: The program web site listed above links to the Maryland Public Service Commission's Net Metering Working Group page, which contains a variety of information resources related to the ongoing implementation of net metering in Maryland, such as meeting agendas, minutes, and draft utility tariffs.

63

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial Residential Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Solar Home Weatherization Program Info State District of Columbia Program Type Net Metering Provider DC Public Service Commission In the District of Columbia (DC), net metering is currently available to residential and commercial customer-generators with systems powered by renewable-energy sources, combined heat and power (CHP), fuel cells and microturbines, with a maximum capacity of 1 megawatt (MW). The term "renewable energy sources" is defined as solar, wind, tidal, geothermal, biomass, hydroelectric power and digester gas. In October 2008, the Clean

64

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Biofuels Alternative Fuel Vehicles Commercial Heating & Cooling Manufacturing Buying & Making Electricity Hydrogen & Fuel Cells Water Energy Sources Solar Home Weatherization Wind Program Info State New Hampshire Program Type Net Metering Provider New Hampshire Public Utilities Commission New Hampshire requires all utilities selling electricity in the state to offer net metering to customers who own or operate systems up to one megawatt (1 MW) in capacity that generate electricity using solar, wind, geothermal, hydro, tidal, wave, biomass, landfill gas, bio-oil or

65

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Buying & Making Electricity Water Solar Home Weatherization Wind Program Info State Virginia Program Type Net Metering Provider Virginia Department of Mines, Minerals, and Energy '''''Note: In March 2011, Virginia enacted HB 1983, which increased the residential net-metering limit to 20 kW. However, residential facilities with a capacity of greater than 10 kW must pay a monthly standby charge. The Virginia State Corporation Commission approved standby charges for transmissions and distribution components as proposed by Virginia Electric and Power Company (Dominion Virginia Power) on November 3, 2011.'''''

66

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Industrial Residential Local Government Multi-Family Residential Nonprofit Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Solar Home Weatherization Wind Program Info State West Virginia Program Type Net Metering Provider West Virginia Public Service Commission Net metering in West Virginia is available to all retail electricity customers. System capacity limits vary depending on the customer type and electric utility type, according to the following table. Customer Type IOUs with 30,000 customers or more IOUs with fewer than 30,000 customers, municipal utilities, electric cooperatives

67

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Wind Solar Home Weatherization Water Program Info State New York Program Type Net Metering Provider New York State Department of Public Service Note: In October 2012 the New York Public Service Commission (PSC) issued an order directing Central Hudson Gas and Electric to file net metering tariff revisions tripling the aggregate net metering cap for most systems from 1% of 2005 peak demand (12 MW) to 3% of 2005 peak demand (36 MW). The PSC issued another order in June 2013 to raise the aggregate net metering cap

68

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Wind Solar Home Weatherization Program Info State Illinois Program Type Net Metering Provider Illinois Commerce Commission '''''NOTE: Legislation enacted in 2011 and 2012 (S.B. 1652, H.B. 3036, and S.B. 3811) has changed several aspects of net metering in Illinois. For customers in competitive classes as of July 1, 2011, the law prescribes a dual metering and bill crediting system which does not meet the definition of net metering as the term is generally defined. Click here for information regarding competitive classes, and

69

Net Metering | Open Energy Information  

Open Energy Info (EERE)

Metering Metering Jump to: navigation, search For electric customers who generate their own electricity, net metering allows for the flow of electricity both to and from the customer,– typically through a single, bi-directional meter. With net metering, when a customer’'s generation exceeds the customer’'s use, the customer's electricity flows back to the grid, offsetting electricity consumed by the customer at a different time. In effect, the customer uses excess generation to offset electricity that the customer otherwise would have to purchase at the utility’'s full retail rate. Net metering is required by law in most states, but some of these laws only apply to investor-owned utilities,– not to municipal utilities or electric cooperatives. [1] Net Metering Incentives

70

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial General Public/Consumer Industrial Residential Fed. Government Local Government State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Water Solar Home Weatherization Wind Program Info State Oklahoma Program Type Net Metering Provider Oklahoma Corporation Commission Net metering has been available in Oklahoma since 1988 under Oklahoma Corporation Commission (OCC) Order 326195. The OCC's rules require investor-owned utilities and electric cooperatives under the commission's jurisdiction* to file net-metering tariffs for customer-owned renewable-energy systems and combined-heat-and-power (CHP) facilities up to 100 kilowatts (kW) in capacity. Net metering is available to all customer

71

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial Industrial Residential Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Wind Solar Home Weatherization Program Info State Ohio Program Type Net Metering Provider Ohio Public Utilities Commission '''''Note: In July 2012, the Public Utilities Commission of Ohio (PUCO) opened a docket ([http://dis.puc.state.oh.us/CaseRecord.aspx?CaseNo=12-2050-EL-ORD Case 12-0250-EL-RDR]) to review the net metering rules for investor-owned utilities. Details will be posted as more information is available.''''' Ohio's net-metering law requires electric distribution utilities to offer net metering to customers who generate electricity using wind energy, solar energy, biomass, landfill gas, hydropower, fuel cells or microturbines.

72

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial Industrial Residential Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Solar Home Weatherization Program Info State New Mexico Program Type Net Metering Provider New Mexico Public Regulation Commission Net metering is available to all "qualifying facilities" (QFs), as defined by the federal Public Utility Regulatory Policies Act of 1978 (PURPA)*, which pertains to systems up to 80 megawatts (MW) in capacity. Previously, net metering in New Mexico was limited to systems up to 10 kilowatts (kW) in capacity. Net-metered customers are credited or paid for any monthly net excess generation (NEG) at the utility's avoided-cost rate. If a customer has net

73

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Net Metering Net Metering < Back Eligibility Commercial Fed. Government Local Government Residential State Government Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Hawaii Program Type Net Metering Provider Hawaii Public Utilities Commission NOTE: Kauai Island Electric Cooperative's (KIUC) net metering program has reached its capacity and has implemented a Net Energy Metering Pilot Program. Hawaii's original net-metering law was enacted in 2001 and expanded in 2004 by HB 2048, which increased the eligible capacity limit of net-metered systems from 10 kilowatts (kW) to 50 kW. In 2005, the law was further amended by SB 1003, which authorized the Hawaii Public Utilities Commission

74

Advanced Metering - Using advanced Metering to Improve Building...  

Broader source: Energy.gov (indexed) [DOE]

bills *Tenant energy use (sub metering) *Identifying best rates *Participating in demand response programs OptimizeReview performance *Diagnose equipment & systems operations...

75

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial Industrial Residential Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Water Energy Sources Solar Home Weatherization Wind Program Info State Minnesota Program Type Net Metering Provider Minnesota Department of Commerce '''''Note: H.F. 729, enacted in May 2013, includes many changes to Minnesota's net metering law. These changes are described above, but most will not take effect until rules are implemented at the PUC. The below summary reflects the current rules.''''' Minnesota's net-metering law, enacted in 1983, applies to all investor-owned utilities, municipal utilities and electric cooperatives. All "qualifying facilities" less than 40 kilowatts (kW) in capacity are

76

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Energy Sources Solar Home Weatherization Wind Program Info State Pennsylvania Program Type Net Metering Provider Pennsylvania Public Utility Commission Note: In March 2012 the Pennsylvania Public Utilities Commission (PUC) issued a Final Order (Docket M-2011-2249441) approving the use of third-party ownership models (i.e., system leases or retail power purchase agreements) in conjunction with net metering. The Order allows these types of arrangements for net metered systems, subject to a restriction that the

77

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Net Metering Net Metering < Back Eligibility Commercial Industrial Residential Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Iowa Program Type Net Metering Provider Iowa Utilities Board Iowa's statutes do not explicitly authorize the Iowa Utilities Board (IUB) to mandate net metering, but this authority is implicit through the board's enforcement of PURPA and Iowa Code § 476.41 ''et seq.'' Iowa's net-metering subrule, adopted by the IUB in July 1984, applies to customers that generate electricity using alternate energy production facilities (AEPs). Net metering is available to all customer classes of Iowa's two investor-owned utilities -- MidAmerican Energy and Interstate Power and

78

Electric Metering | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Electric Electric Metering Electric Metering Saving Money by Saving Energy The Department of Energy has installed meters in the James Forrestal Building that will enable DOE to measure electricity use and costs in its headquarters facility. You may explore this data further by visiting our Forrestal Metering Dashboard at the following website: http://forrestal.nrel.gov The Forrestal electric meters provide daily read-outs and comparison of data on electricity consumption for overhead lighting and power outlets. The purpose is to measure the electricity used by equipment that building occupants can control. Data is collected and reported by zones throughout Forrestal's north, south and west buildings. See the Forrestal metering zone map, below, for details on the zones.

79

Common Help Room Hours  

E-Print Network [OSTI]

Common Help Room Hours for Spring 2015. Monday, Tuesday, Wednesday, Thursday, Friday. 10:30 am. 11:30 am. MA 16200 - MATH 205 - Nathanael Cox...

80

Common Help Room Hours  

E-Print Network [OSTI]

Common Help Room Hours for Spring 2015. Monday, Tuesday, Wednesday, Thursday, Friday. 10:30 am. 11:30 am. MA 16010 - MATH 205 - Alessandra...

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Contacts / Hours - Hanford Site  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Station Real Time Met Data from Around the Site Current HMS Observations Daily HMS Extremes in Met Data Met and Climate Data Summary Products Contacts Hours Current NWS...

82

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Residential Residential Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Wind Solar Home Weatherization Program Info State Louisiana Program Type Net Metering Provider Louisiana Public Service Commission '''''Note: Ongoing proceedings related to net metering can be found in Docket R-31417.''''' Louisiana enacted legislation in June 2003 establishing net metering. Modeled on Arkansas's law, Louisiana's law requires investor-owned utilities, municipal utilities and electric cooperatives to offer net metering to customers that generate electricity using solar, wind, hydropower, geothermal or biomass resources. Fuel cells and microturbines that generate electricity entirely derived from renewable resources are

83

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Multi-Family Residential Nonprofit Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Connecticut Program Type Net Metering Provider Public Utilities Regulatory Authority Connecticut's two investor-owned utilities -- Connecticut Light and Power Company (CL&P) and United Illuminating Company (UI) -- are required to provide net metering to customers that generate electricity using "Class I" renewable-energy resources, which include solar, wind, landfill gas, fuel

84

O&M Metering Guidance  

Broader source: Energy.gov [DOE]

Presentation covers the O&M Metering Guidance and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Rapid City, South Dakota.

85

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Agricultural Agricultural Commercial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Kentucky Program Type Net Metering Provider Kentucky Public Service Commission In April 2008, Kentucky enacted legislation that expanded its net metering law by requiring utilities to offer net metering to customers that generate electricity with photovoltaic (PV), wind, biomass, biogas or hydroelectric systems up to 30 kilowatts (kW) in capacity. The Kentucky Public Service Commission (PSC) issued rules on January 8, 2009. Utilities had 90 days from that date to file tariffs that include all terms and conditions of their net metering programs, including interconnection.

86

LIBRARY SERVICES LIBRARY HOURS  

E-Print Network [OSTI]

LIBRARY SERVICES LIBRARY HOURS Up-to-date library hours are posted at http Wesleyan ID that is linked to the library circulation database is needed to charge out library materials to visit the Circulation Office in Olin Library 115 to set up their borrowing privileges. If you have

Royer, Dana

87

Impact of orifice metering uncertainties  

SciTech Connect (OSTI)

In a recent utility study, attributed 38% of its unaccounted-for UAF gas to orifice metering uncertainty biasing caused by straightening vanes. How this was determined and how this applied to the company's orifice meters is described. Almost all (97%) of the company's UAF gas was found to be attributed to identifiable accounting procedures, measurement problems, theft and leakage.

Stuart, J.W. (Pacific Gas and Electric Co., San Francisco, CA (USA))

1990-12-01T23:59:59.000Z

88

Wavelength meter having elliptical wedge  

DOE Patents [OSTI]

A wavelength meter is disclosed which can determine the wavelength of a laser beam from a laser source within an accuracy range of two parts in 10.sup.8. The wavelength meter has wedge having an elliptically shaped face to the optical path of the laser source and includes interferometer plates which form a vacuum housing.

Hackel, Richard P. (Livermore, CA); Feldman, Mark (Livermore, CA)

1992-01-01T23:59:59.000Z

89

Wavelength meter having elliptical wedge  

DOE Patents [OSTI]

A wavelength meter is disclosed which can determine the wavelength of a laser beam from a laser source within an accuracy range of two parts in 10[sup 8]. The wavelength meter has wedge having an elliptically shaped face to the optical path of the laser source and includes interferometer plates which form a vacuum housing. 7 figs.

Hackel, R.P.; Feldman, M.

1992-12-01T23:59:59.000Z

90

Gerson Recinos Onramp Metering System  

E-Print Network [OSTI]

Gerson Recinos Onramp Metering System Using Arduino and Processing Overview­ For this project I built an Onramp Metering System using Arduino and Processing. The Microcontroller used was Arduino (based on Atmel168) and the programming languages were Processing and Wiring (derivative

Kachroo, Pushkin

91

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Tribal Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Solar Water Wind Program Info State New Jersey Program Type Net Metering Provider New Jersey Board of Public Utilities New Jersey's net-metering rules apply to all residential, commercial and industrial customers of the state's investor-owned utilities and energy suppliers (and certain competitive municipal utilities and electric cooperatives). Systems that generate electricity using solar, wind, geothermal, wave, tidal, landfill gas or sustainable biomass resources, including fuel cells (all "Class I" technologies under the state RPS), are

92

Metering Process | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Process Process Metering Process October 7, 2013 - 9:34am Addthis Developing and implementing a metering plan is highly dependent on the individual facility's needs, mission, metering equipment, and available infrastructure. One size does not fit all. The following guidelines outline the typical process for planning and implementing a metering program. Establish Program Goals and Objectives Establishing program goals and objectives is the critical first step for all metering programs. While the ultimate goal is usually measuring and lowering utility use or costs, the objectives needed to get this done varies. Examples of program objectives include: To fully enable energy bill allocation throughout the facility To effectively manage electric loads and minimize costs under a

93

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Net Metering Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Michigan Program Type Net Metering Provider Michigan Public Service Commission '''''The MPSC is reviewing state interconnection and net metering policies in [http://efile.mpsc.state.mi.us/efile/viewcase.php?casenum=15919&submit.x=... Case U-15919].''''' In October 2008, Michigan enacted legislation (P.A. 295) requiring the Michigan Public Service Commission (PSC) to establish a statewide net metering program for renewable-energy systems within 180 days. On May 26, 2009 the Michigan Public Service Commission (PSC) issued an order formally

94

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Commercial Industrial Residential Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Solar Home Weatherization Wind Program Info State Colorado Program Type Net Metering Provider Colorado Public Utilities Commission [http://www.leg.state.co.us/clics/clics2009a/csl.nsf/fsbillcont3/571064D8... Senate Bill 51] of April 2009 made several changes, effective September 1, 2009, to the state's net metering rules for investor-owned utilities, as they apply to solar-electric systems. These changes include converting the maximum system size for solar-electric systems from two megawatts (MW) to 120% of the annual consumption of the site; redefining a site to include

95

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Net Metering < Back Eligibility Agricultural Commercial Industrial Residential Fed. Government General Public/Consumer Local Government Low-Income Residential Multi-Family Residential Nonprofit Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Solar Wind Program Info State California Program Type Net Metering Provider California Public Utilities Commission California's net-metering law originally took effect in 1996 and applies to all utilities with one exception*. The law has been amended numerous times since its enactment, most recently by AB 327 of 2013. '''Eligible Technologies''' The original law applied to wind-energy systems, solar-electric systems and hybrid (wind/solar) systems. In September 2002, legislation (AB 2228)

96

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Alternative Fuel Vehicles Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Delaware Program Type Net Metering Provider Delaware Public Service Commission In Delaware, net metering is available to any customer that generates electricity using solar, wind or hydro resources, anaerobic digesters, or fuel cells capable of being powered by renewable fuels. Grid-interactive electric vehicles are also eligible for net metering treatment for electricity that they put on the grid, although these vehicles do not themselves generate electricity. The maximum capacity of a net-metered system is 25 kilowatts (kW) for residential customers; 100 kW for farm customers on residential rates; two megawatts (MW) per meter for

97

2,279 METERS BOUYANT POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,279 METERS BOUYANT POLYOLEFIN MOORING LINE 4,900 METERS NYLON LINE, CONTINUOUS 700 METERS KEO 1: DATE: DATE: MOORING: SCOPE: NOAA-PMEL-KE 1.4:1 TC5 METERS 700 METERS WIRE ROPE FAIRING TO 500 METERS TC10 METERS 50 METERS 25 METERS TC TC 75 METERS TC 100 METERS TP 150 METERS TC 200 METERS TC 300 METERS

98

hourly | OpenEI  

Open Energy Info (EERE)

hourly hourly Dataset Summary Description This dataset contains hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). This dataset also includes the Residential Energy Consumption Survey (RECS) for statistical references of building types by location. Source Commercial and Residential Reference Building Models Date Released April 18th, 2013 (7 months ago) Date Updated July 02nd, 2013 (5 months ago) Keywords building building demand building load Commercial data demand Energy Consumption energy data hourly kWh load profiles Residential Data Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually

99

Federal Energy Management Program: Metering Systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Metering Systems Metering Systems to someone by E-mail Share Federal Energy Management Program: Metering Systems on Facebook Tweet about Federal Energy Management Program: Metering Systems on Twitter Bookmark Federal Energy Management Program: Metering Systems on Google Bookmark Federal Energy Management Program: Metering Systems on Delicious Rank Federal Energy Management Program: Metering Systems on Digg Find More places to share Federal Energy Management Program: Metering Systems on AddThis.com... Sustainable Buildings & Campuses Operations & Maintenance Federal Requirements Program Management Commissioning Metering Systems Approaches Process Computerized Maintenance Management Systems Maintenance Types Major Equipment Types Resources Contacts Greenhouse Gases Water Efficiency

100

Smart meters | Open Energy Information  

Open Energy Info (EERE)

meters meters Jump to: navigation, search Smart meters are part of the initiative to install a smart grid to better power the United States in the coming year, helping incorporate renewable energy technologies into the grid while also making the existing grid more efficient. About Smart Grid Smartgridlogo.png The purpose of smart meters is to aid development of the United States Smart Grid initiative. The purpose of Smart Grid "to support the modernization of the nation's electricity transmission and distribution system to maintain a reliable and secure electricity infrastructure, outlined in Title XIII of the Energy Independence and Security Act of 2007 (PDF 821 KB)." More in-depth information can be found at SmartGrid.gov. It is believed that the implementation of a new Smart Grid "will make our grid more secure

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Electric Metering | Department of Energy  

Office of Environmental Management (EM)

has installed meters in the James Forrestal Building that will enable DOE to measure electricity use and costs in its headquarters facility. You may explore this data further by...

102

Valley Electric Association- Net Metering  

Broader source: Energy.gov [DOE]

The Board of Directors for Valley Electric Association (VEA) approved net metering in April 2008. The rules apply to systems up to 30 kW, though owners of larger systems may be able to negotiate...

103

Gamma radiation field intensity meter  

DOE Patents [OSTI]

A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode. 4 figs.

Thacker, L.H.

1995-10-17T23:59:59.000Z

104

Gamma radiation field intensity meter  

DOE Patents [OSTI]

A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode. 4 figs.

Thacker, L.H.

1994-08-16T23:59:59.000Z

105

Gamma radiation field intensity meter  

DOE Patents [OSTI]

A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode.

Thacker, Louis H. (Knoxville, TN)

1995-01-01T23:59:59.000Z

106

Gamma radiation field intensity meter  

DOE Patents [OSTI]

A gamma radiation intensity meter measures dose rate of a radiation field. The gamma radiation intensity meter includes a tritium battery emitting beta rays generating a current which is essentially constant. Dose rate is correlated to an amount of movement of an electroscope element charged by the tritium battery. Ionizing radiation decreases the voltage at the element and causes movement. A bleed resistor is coupled between the electroscope support element or electrode and the ionization chamber wall electrode.

Thacker, Louis H. (Knoxville, TN)

1994-01-01T23:59:59.000Z

107

START USING THE NEW ONLINE METER  

E-Print Network [OSTI]

START USING THE NEW ONLINE METER REQUEST FORM TOOL CAS login Logging in with your Princeton Net and convenient way for departments to send outgoing metered mail with Mail Services! The new Online Meter Request

Singh, Jaswinder Pal

108

Microsoft Word - CX -Lewis County PUD metering_.doc  

Broader source: Energy.gov (indexed) [DOE]

KEC-4 KEC-4 SUBJECT: Environmental Clearance Memorandum John Brank Project Manager - TPC-Olympia Proposed Action: Installation of metering equipment at existing facilities for power scheduling. Budget Information: Work order 00202861, Task 01 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.6 Additions or modifications to electric power transmission facilities that would not affect the environment beyond the previously developed facility area... Location: Lewis County, Washington Proposed by: BPA Description of the Proposed Action: BPA proposes to install meter equipment at multiple locations in Lewis County, Washington. The project is needed as Lewis county PUD plans to become a BPA Slice customer and needs to obtain meter data at 5 minute intervals. The

109

DVS5.2 METERS 8 METERS OCR507, STOR-X DATA LOGGER  

E-Print Network [OSTI]

DVS5.2 METERS 10 METERS 8 METERS OCR507, STOR-X DATA LOGGER 16" BATTERY HOUSING TC INVERTED5 METERS 1" SAS INDUCTIVE CABLE BREAKOUT RADAR REFLECTOR OS PAPA RECOVERY HANDLE 1 METER-SBE 37 MICROCAT TC HUMIDITY (FLEX) CTD/GTD/O2 4 METERS WETLabs FLNTUSB FLUOROMETER DOUBLE NUT AND TORQUE ALL LOAD CELL NUTS

110

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Agricultural Agricultural Commercial Fed. Government Industrial Institutional Local Government Multi-Family Residential Nonprofit Residential Schools State Government Tribal Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Heating & Cooling Commercial Heating & Cooling Wind Program Info State Indiana Program Type Net Metering Provider Indiana Utility Regulatory Commission The Indiana Utility Regulatory Commission (IURC) adopted rules for net metering in September 2004, requiring the state's investor-owned utilities (IOUs) to offer net metering to all electric customers. The rules, which apply to renewable energy resource projects [defined by IC 8-1-37-4(a)(1) - (8)] with a maximum capacity of 1 megawatt (MW), include the following

111

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Agricultural Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Oregon Program Type Net Metering Oregon has established separate net-metering programs for the state's primary investor-owned utilities (PGE and PacifiCorp), and for its municipal utilities and electric cooperatives. '''PGE and PacifiCorp Customers''' The Oregon Public Utilities Commission (PUC) adopted new rules for net metering for PGE and PacifiCorp customers in July 2007, raising the individual system limit from 25 kilowatts (kW) to two megawatts (MW) for non-residential applications. (The rules do not apply to customers of Idaho

112

NERSC Edison Hours Used Report  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Hours Used Edison Hours Used 2014 Edison Usage Chart Edison Usage Chart 2013 Edison Usage Chart Edison Usage Chart 2014 Date Hours Used (in millions) Percent of Maximum Possible...

113

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Institutional Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Solar Home Weatherization Wind Program Info State Arizona Program Type Net Metering Provider Arizona Corporation Commission Net metering is available to customers who generate electricity using solar, wind, hydroelectric, geothermal, biomass, biogas, combined heat and power (CHP) or fuel cell technologies. The ACC has not set a firm kilowatt-based limit on system size capacity; instead, systems must be sized to not exceed 125% of the customer's total connected load. If there is no available load data for the customer, the generating system may not

114

Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Industrial Industrial Residential Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Water Energy Sources Solar Home Weatherization Wind Program Info State Wisconsin Program Type Net Metering Provider Public Service Commission of Wisconsin The Public Service Commission of Wisconsin (PSC) issued an order on January 26, 1982 requiring all regulated utilities to file tariffs allowing net metering to customers that generate electricity with systems up to 20 kilowatts (kW)* in capacity. The order applies to investor-owned utilities and municipal utilities, but not to electric cooperatives. All distributed-generation (DG) systems, including renewables and combined heat and power (CHP), are eligible. There is no limit on total enrollment.

115

Station design using orifice meters  

SciTech Connect (OSTI)

This paper reports that proper meter station design using gas orifice meters must include consideration of a number of factors to minimize operation and maintenance problems while obtaining the best accuracy over the life of the station. A station should provide accuracy, be safe, functional, economical and free of undue maintenance. It should comply with all codes, reports and specifications but most of all it should be able to comply with terms set forth in the contract. All measuring stations should be designed with considerations of growth or reductions in volume. It should be attractive and built to last for many years.

Upp, E.L. (Daniel Industries, Inc., Houston, TX (United States))

1992-07-01T23:59:59.000Z

116

Hardware Metering: A Survey Farinaz Koushanfar  

E-Print Network [OSTI]

Chapter 1 Hardware Metering: A Survey Farinaz Koushanfar Abstract This chapter provides the first comprehensive overview of hard- ware integrated circuits (IC) protection by metering. Hardware metering, or IC metering refers to mechanisms, methods, and protocols that enable track- ing of the ICs post

117

meter:alittlelonger kilometer:alittlemore  

E-Print Network [OSTI]

Yard Meter meter:alittlelonger thanayard mile kilometer kilometer:alittlemore thanhalfamile gramM1000000 gigaG1000000000 COMMONPREFIXES 1 8765432 9 161514131211101 8765432 9 16151413121110 cm Yard Meter meter:alittlelonger thanayard mile kilometer kilometer:alittlemore thanhalfamile gram

118

Federal Energy Management Program: Metering Process  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Process Process to someone by E-mail Share Federal Energy Management Program: Metering Process on Facebook Tweet about Federal Energy Management Program: Metering Process on Twitter Bookmark Federal Energy Management Program: Metering Process on Google Bookmark Federal Energy Management Program: Metering Process on Delicious Rank Federal Energy Management Program: Metering Process on Digg Find More places to share Federal Energy Management Program: Metering Process on AddThis.com... Sustainable Buildings & Campuses Operations & Maintenance Federal Requirements Program Management Commissioning Metering Systems Approaches Process Computerized Maintenance Management Systems Maintenance Types Major Equipment Types Resources Contacts Greenhouse Gases Water Efficiency Data Center Energy Efficiency

119

FALL AND SPRING Per Hour # Hours # Semesters Total  

E-Print Network [OSTI]

$4,060.00 FALL AND SPRING Per Hour # Hours # Semesters Total Tuition $765.00 15 2 $22,950.00 ISS, Engineering, Journalism & Mass Communications, Music and Social Welfare fees. These amounts do NOT include to complete at least 12 hours each fall and spring semester. Calculations are based on 15 hours (an average

120

Alternative Fuels Data Center: Natural Gas Metering  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Natural Gas Metering Natural Gas Metering to someone by E-mail Share Alternative Fuels Data Center: Natural Gas Metering on Facebook Tweet about Alternative Fuels Data Center: Natural Gas Metering on Twitter Bookmark Alternative Fuels Data Center: Natural Gas Metering on Google Bookmark Alternative Fuels Data Center: Natural Gas Metering on Delicious Rank Alternative Fuels Data Center: Natural Gas Metering on Digg Find More places to share Alternative Fuels Data Center: Natural Gas Metering on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Natural Gas Metering Individuals who use natural gas for residential or other tax-free purposes may not use natural gas in motor vehicles unless the natural gas is obtained through a separate meter installed by the alternative fuels

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

2,270 METERS BOUYANT POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,270 METERS BOUYANT POLYOLEFIN MOORING LINE 10 METER LENGTH NYLON STIFFENER APPLIED TO 1" NYLON 3/4" SAS EYE INTO EYE SPLICE ACOUSTIC RELEASE 20 METERS 1 1/8" NYLON 5/8" SAS 5/8" SAS 3/4" SAS .5 METER CHAIN 697.4 METERS 7/16" WIRE ROPE 7.1 METERS 10 METERS 37.1 METERS 75 METERS 100 METERS 125 METERS 225

122

2,309 METERS BOUYANT POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,309 METERS BOUYANT POLYOLEFIN MOORING LINE 10 METER LENGTH NYLON STIFFENER APPLIED TO 1" NYLON EYE INTO EYE SPLICE 20 METERS 1 1/8" NYLON 697.4 METERS 7/16" WIRE ROPE 36.1 METERS TC inverted35 METERS 40 METERS 700 METERS 3/4" SAS, Wrench tighten. ** 3/4" SAS WITH BUSHING, Wrench tighten. ** .5

123

Metering Approaches | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Approaches Approaches Metering Approaches October 7, 2013 - 9:24am Addthis Metering approaches vary depending on facility design and intended purpose (e.g., administrative offices, laboratory, warehouse, etc.). No one approach fits all applications. In fact, different approaches are often needed at different times. For example, a different approach is needed depending on whether the program is trying to verify utility rates, implement demand response or load management programs, or support certification efforts. One-Time Measurements One-time measurements are useful in many baseline activities to understand instantaneous energy use, equipment performance, or loading. These measurements become particularly useful in trending equipment performance over time. For example, one-time measurements are useful when an energy-efficiency

124

Electrical Metering Equipment and Sensors Appendix D -Electrical Metering Equipment and Sensors  

E-Print Network [OSTI]

Appendix D ­ Electrical Metering Equipment and Sensors #12;D.1 Appendix D - Electrical Metering schedules, and view system status from the convenience of a standard web-browser. D.2 Metering Data Logger

125

Federal Building Metering Guidance (Per U.S.C. 8253(e), Metering of Energy Use)  

Broader source: Energy.gov [DOE]

Guidance defines which Federal buildings are appropriate to meter, provides metering prioritization recommendations for agencies with limited resources, and discusses the requirement for agencies to submit metering implementation plans the U.S. Department of Energy.

126

Government Program Briefing: Smart Metering  

Office of Energy Efficiency and Renewable Energy (EERE)

This document is adapted and updated from a memo delivered to the City Council of New Orleans, the office of the Mayor of New Orleans, the Chairperson of the Citizen Stakeholders Group (New Orleans Energy Task Force) and the U.S. Department of Energy (DOE) Project Officer in March 2008. This briefing piece provides an overview of the benefits, costs, and challenges of smart metering.

127

Dynamics of acyclic interval maps  

E-Print Network [OSTI]

Vol. 6 (2009) Dynamics of acyclic interval maps [16] D.orbits and bifurcation of maps of the interval. SIAM J.Dynamics of acyclic interval maps Morris W. Hirsch He who

Hirsch, Morris W

2009-01-01T23:59:59.000Z

128

Idaho Power - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Idaho Power - Net Metering < Back Eligibility Agricultural Commercial Residential Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Idaho Program Type Net Metering Provider Idaho Power Company Idaho does not have a statewide net-metering policy. However, each of the state's three investor-owned utilities -- Avista Utilities, Idaho Power and Rocky Mountain Power -- has developed a net-metering tariff that has been approved by the Idaho Public Utilities Commission (PUC). The framework of the utilities' net-metering programs is similar, in that each utility: (1) offers net metering to customers that generate electricity using solar, wind, hydropower, biomass or fuel cells; (2) limits residential systems to

129

greenMeter | Open Energy Information  

Open Energy Info (EERE)

greenMeter greenMeter Jump to: navigation, search Tool Summary LAUNCH TOOL Name: greenMeter Agency/Company /Organization: Hunter Research & Technology Sector: Energy Focus Area: Energy Efficiency Resource Type: Software/modeling tools User Interface: Mobile Device Website: hunter.pairsite.com/greenmeter/ Web Application Link: hunter.pairsite.com/greenmeter/ Cost: Paid greenMeter Screenshot References: greenMeter[1] Logo: greenMeter greenMeter is an app for the iPhone and iPod Touch that computes your vehicle's power and fuel usage characteristics and evaluates your driving to increase efficiency, reduce fuel consumption and cost, and lower your environmental impact. Results are displayed in real time, while driving, to give instantaneous feedback. Overview Using accelerometer data and the advanced physics engine from the gMeter

130

Avista Utilities - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Avista Utilities - Net Metering Avista Utilities - Net Metering Avista Utilities - Net Metering < Back Eligibility Agricultural Commercial Residential Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Idaho Program Type Net Metering Provider Avista Utilities Idaho does not have a statewide net-metering policy. However, each of the state's three investor-owned utilities -- Avista Utilities, Idaho Power and Rocky Mountain Power -- has developed a net-metering tariff that has been approved by the Idaho Public Utilities Commission (PUC). The framework of the utilities' net-metering programs is similar, in that each utility: (1) offers net metering to customers that generate electricity using solar,

131

NASA's Metering Plan | Department of Energy  

Energy Savers [EERE]

NASA's Metering Plan NASA's Metering Plan Presentation covers NASA's Meterting Plan and is given at the FUPWG 2006 Spring meeting, held on May 3-4, 2006 in Atlanta, Georgia....

132

Metered Mail Form International Mail Only  

E-Print Network [OSTI]

Metered Mail Form International Mail Only Charge to Department USPS First Class Mail International International Metered Mail Form and must be kept separate from all other domestic mail. · International mail

Palmeri, Thomas

133

Heating Energy Meter Validation for Apartments  

E-Print Network [OSTI]

Household heat metering is the core of heating system reform. Because of many subjective and objective factors, household heat metering has not been put into practice to a large extent in China. In this article, the research subjects are second...

Cai, B.; Li, D.; Hao, B.

2006-01-01T23:59:59.000Z

134

Energy Measurement Techniques for Smart Metering  

Science Journals Connector (OSTI)

This chapter discusses topology, architecture and circuit design of energy measurement unit for Smart Metering. The chapter establishes step-by-step design methodology of energy measurement unit of a smart meter ...

Sumit Adhikari

2013-01-01T23:59:59.000Z

135

Dead-time compensation for a logarithmic display rate meter  

DOE Patents [OSTI]

An improved circuit is provided for application to a radiation survey meter that uses a detector that is subject to dead time. The circuit compensates for dead time over a wide range of count rates by producing a dead-time pulse for each detected event, a live-time pulse that spans the interval between dead-time pulses, and circuits that average the value of these pulses over time. The logarithm of each of these values is obtained and the logarithms are subtracted to provide a signal that is proportional to a count rate that is corrected for the effects of dead time. The circuit produces a meter indication and is also capable of producing an audible indication of detected events.

Larson, John A. (Aurora, IL); Krueger, Frederick P. (Aurora, IL)

1988-09-20T23:59:59.000Z

136

Dead-time compensation for a logarithmic display rate meter  

DOE Patents [OSTI]

An improved circuit is provided for application to a radiation survey meter that uses a detector that is subject to dead time. The circuit compensates for dead time over a wide range of count rates by producing a dead-time pulse for each detected event, a live-time pulse that spans the interval between dead-time pulses, and circuits that average the value of these pulses over time. The logarithm of each of these values is obtained and the logarithms are subtracted to provide a signal that is proportional to a count rate that is corrected for the effects of dead time. The circuit produces a meter indication and is also capable of producing an audible indication of detected events. 5 figs.

Larson, J.A.; Krueger, F.P.

1987-10-05T23:59:59.000Z

137

NERSC Hopper Hours Used Report  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Hours Used Hopper Hours Used 2014 Hopper Usage Chart Hopper Usage Chart 2013 Hopper Usage Chart Hopper Usage Chart 2012 Hopper Usage Chart Hopper Usage Chart 2011 Hopper Usage...

138

DOE Releases Federal Building Metering Guidance  

Broader source: Energy.gov [DOE]

The guidance requires federal agencies to review, revise, and submit to FEMP its metering implementation plan within one year.

139

Metering Schemes for General Access Structures  

E-Print Network [OSTI]

Metering Schemes for General Access Structures Barbara Masucci Dipartimento di Informatica ed, Canada E­mail: dstinson@cacr.math.uwaterloo.ca Abstract A metering scheme is a method by which an audit time frame. In this paper we construct metering schemes for more general access structures, which

Stinson, Douglas

140

A PHOTOELECTRIC CURRENT METER Marine Biological Laboratory!  

E-Print Network [OSTI]

330 A PHOTOELECTRIC CURRENT METER Marine Biological Laboratory! WOODS HOLE, MASS. SPECIAL CURRENT METER by H. C. Boyar Fishery Research Biologist Bureau of Commercial Fisheries Biological. March 1960 #12;#12;TABLE OF CONTENTS Page Introduction 1 Description and operation of the meter

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

THE ELECTRICAL RESISTIVITY METER IN FISHERY INVESTIGATIONS  

E-Print Network [OSTI]

THE ELECTRICAL RESISTIVITY METER IN FISHERY INVESTIGATIONS I Marine Biological Laboratory! WOODS RESISTIVITY METER IN FISHERY INVESTIGATIONS By Robert E. Lennon Fishery Research Biologist Appalachian Sport) BiblioKiMpliy : p. ]!. 1. Electric meters. 2. Water--Analysis. 3. Electric fishing. I. Title. ( Series

142

Metered Mail Form Domestic Mail Only  

E-Print Network [OSTI]

Metered Mail Form Domestic Mail Only For USPS Mail Only Charge to Department First Class Mail Media Meter Form. · All outgoing USPS Mail that needs postage should be kept separate from all other mail already be sealed prior to being metered. Failure to properly seal this type of mail could result

Palmeri, Thomas

143

Smart Meter Security Infrastructure: Some Observations  

E-Print Network [OSTI]

to infer otherwise-private life-style details of the Smart Meter user. 2 An attacker who can issue on the capa- bility of the device, such an attacker can reset a Smart Meter, cut off electricity supply, access Smart Grid nodes via the Smart Meter, or pretend electricity use that is other than the actual use

Ladkin, Peter B.

144

Monitoring the Thermal Power of Nuclear Reactors with a Prototype Cubic Meter Antineutrino Detector  

E-Print Network [OSTI]

In this paper, we estimate how quickly and how precisely a reactor's operational status and thermal power can be monitored over hour to month time scales, using the antineutrino rate as measured by a cubic meter scale detector. Our results are obtained from a detector we have deployed and operated at 25 meter standoff from a reactor core. This prototype can detect a prompt reactor shutdown within five hours, and monitor relative thermal power to three percent within seven days. Monitoring of short-term power changes in this way may be useful in the context of International Atomic Energy Agency's (IAEA) Reactor Safeguards Regime, or other cooperative monitoring regimes.

A. Bernstein; N. S. Bowden; A. Misner; T. Palmer

2008-04-30T23:59:59.000Z

145

Melodic cues to meter 1 Running Head: MELODIC CUES TO METER  

E-Print Network [OSTI]

Melodic cues to meter 1 Running Head: MELODIC CUES TO METER The Role of Melodic and Temporal Cues in Perceiving Musical Meter Erin E. Hannon Cornell University Joel S. Snyder Cornell University Tuomas Eerola-569-4326 Tel: 905-828-5415 E-mail: eeh5@cornell.edu #12;Melodic cues to meter 2 Abstract A number of different

Ahmad, Sajjad

146

ANALYSIS OF HIGH PRESSURE TESTS ON WET GAS FLOW METERING WITH A VENTURI METER  

E-Print Network [OSTI]

ANALYSIS OF HIGH PRESSURE TESTS ON WET GAS FLOW METERING WITH A VENTURI METER P. Gajan , Q, 64018 Pau cedex, France pierre.gajan@onera.fr Abstract This work deals with the flow metering of wet gas on the CEESI facilities are presented. They are performed at 75 bars with 0.6 beta ratio Venturi meter

147

PQMII POWER QUALITY METER INSTRUCTION MANUAL 11 PQMII Power Quality Meter  

E-Print Network [OSTI]

#12;#12;#12;PQMII POWER QUALITY METER ­ INSTRUCTION MANUAL 1­1 PQMII Power Quality Meter Chapter 1 Multilin PQMII Power Quality Meter is an ideal choice for continuous monitoring of a single or three-phase system. It provides metering for current, voltage, real power, reactive power, apparent power, energy use

Meyers, Steven D.

148

Ramp meters on trial: Evidence from the Twin Cities metering holiday  

E-Print Network [OSTI]

Ramp meters on trial: Evidence from the Twin Cities metering holiday David Levinson a,*, Lei Zhang; accepted 15 December 2004 Abstract Ramp meters in the Twin Cities have been the subject of a recent test metering for several representative freeways during the afternoon peak period. Seven performance measures

Levinson, David M.

149

2,275 METERS BOUYANT POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,275 METERS BOUYANT POLYOLEFIN MOORING LINE 10 METERS NYLON STIFFENER 3/4" SAS .5 M 1/2" CHAIN 3" GLASS BALL FLOATS on 2.5 M Chain ACOUSTIC RELEASE 20 METERS 1 1/8" NYLON 5/8" SAS 5/8" SAS 3/4" SAS .5 METER CHAIN 5/8" SAS 2 METER CHAIN 697.4 METERS 7/16" WIRE ROPE SONTEK7 METERS 10 METERS 8.3 METERS TV

150

2,279 METERS BOUYANT POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,279 METERS BOUYANT POLYOLEFIN MOORING LINE 10 METERS NYLON STIFFENER 3/4" SAS .5 M 1/2" CHAIN 5 SPLICE 6 ea.17" GLASS BALL FLOATS ACOUSTIC RELEASE 20 METERS 1 1/8" NYLON 5/8" SAS 5/8" SAS 3/4" SAS .5 METER CHAIN 5/8" SAS 2 METER CHAIN TC INVERTED5 METERS 697.4 METERS WIRE ROPE SONTEK7 METERS 10 METERS 8

151

Insights from Smart Meters: The Potential for Peak-Hour Savings from Behavior-Based Programs  

E-Print Network [OSTI]

2012. Evaluation, Measurement, and Verification (EM&V) of2012. Evaluation, Measurement, and Verification (EM&V) ofevaluation, measurement and verification (EM&V) of energy

Todd, Annika

2014-01-01T23:59:59.000Z

152

Insights from Smart Meters: The Potential for Peak-Hour Savings from Behavior-Based Programs  

E-Print Network [OSTI]

andRenewableEnergy(DOEEERE)underLawrenceBerkeleyandRenewableEnergy(DOEEERE)underLawrenceBerkeley

Todd, Annika

2014-01-01T23:59:59.000Z

153

Kansas - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Kansas - Net Metering Kansas - Net Metering Kansas - Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Kansas Program Type Net Metering Provider Kansas Corporation Commission Kansas adopted the Net Metering and Easy Connection Act in May 2009 (see K.S.A. 66-1263 through 66-1271), establishing net metering for customers of investor-owned utilities in Kansas. Net metering applies to systems that generate electricity using solar, wind, methane, biomass or hydro resources, and to fuel cells using hydrogen produced by an eligible

154

Progress Energy - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Progress Energy - Net Metering Progress Energy - Net Metering Progress Energy - Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Tribal Government Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State South Carolina Program Type Net Metering Provider Progress Energy Carolinas In August 2009, the South Carolina Public Service Commission issued an order mandating net metering be made available by the regulated electric utilities; the order incorporates a net metering settlement signed by the individual interveners, the Office of Regulatory Staff and the three investor-owned utilities (IOUs). The order detailed the terms of net metering, including ownership of RECs, in South Carolina and standardized

155

Net Metering Webinar | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Webinar Net Metering Webinar Net Metering Webinar June 25, 2014 11:00AM MDT Attendees will become familiar with the services provided by utility net metering and their importance in making projects cost-effective. The speakers will provide information based on case histories of how facilities that generate their own electricity from renewable energy sources can feed electricity they do not use back into the grid. Many states have net-metering laws with which utilities must comply. In states without such legislation, utilities may offer net-metering programs voluntarily or as a result of regulatory decisions. The webinar will cover the general differences between states' legislation and implementation and how the net-metering benefits can vary widely for facilities in different areas of

156

Duke Energy - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Duke Energy - Net Metering Duke Energy - Net Metering Duke Energy - Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Tribal Government Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State South Carolina Program Type Net Metering In August 2009, the South Carolina Public Service Commission issued an [http://dms.psc.sc.gov/pdf/matters/F05030FC-E19A-9225-B838F72EDF4557DC.pdf] order mandating net metering be made available by the regulating utilities; the order incorporates a net metering settlement signed by the individual interveners, the Office of Regulatory Staff and the three investor-owned utilities (IOUs). The order detailed the terms of net metering, including

157

EPAct 2005 Metering Guidance Overview | Department of Energy  

Energy Savers [EERE]

EPAct 2005 Metering Guidance Overview EPAct 2005 Metering Guidance Overview Presentation covers an overview of the EPAct 2005 Metering Guidance and is given at the FUPWG 2006...

158

FALL AND SPRING Per Hour # Hours # Semesters Total  

E-Print Network [OSTI]

$4,060.00 FALL AND SPRING Per Hour # Hours # Semesters Total Tuition $828.00 15 2 $24,840.00 ISS Living Expenses Please see reverse side for Architecture, Arts, Business, Design & Planning, Engineering to change. Tuition will be guaranteed through spring 2018; however, expect approximately a 5% increase each

159

NERSC Franklin Hours Used Report  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Franklin Hours Used Franklin Hours Used Franklin Hours Used 2011 Franklin Usage in Hours 2011 Franklin Usage in Hours 2010 2010 Franklin Usage in Hours 2009 2009 Franklin Usage in Hours 2007-2008 2008 Franklin Usage in Hours 2008 Franklin Usage in Hours Date Hours Used (in thousands) Percentage of Maximum Possible (24 hours/day) 04/28/2012 0.00 0.00 04/27/2012 272.62 29.40 04/26/2012 692.81 74.71 04/25/2012 841.60 90.75 04/24/2012 53.86 5.81 04/23/2012 432.01 46.59 04/22/2012 823.23 88.77 04/21/2012 473.95 51.11 04/20/2012 173.75 18.74 04/19/2012 449.22 48.44 04/18/2012 816.23 88.02 04/17/2012 754.35 81.34 04/16/2012 648.89 69.97 04/15/2012 812.25 87.59 04/14/2012 843.46 90.95 04/13/2012 737.46 79.52 04/12/2012 711.97 76.77 04/11/2012 734.65 79.22 04/10/2012 815.65 87.95 04/09/2012 897.25 96.75

160

Widget:GoalMeter | Open Energy Information  

Open Energy Info (EERE)

GoalMeter GoalMeter Jump to: navigation, search This widget produces an image showing progress against some numeric goal. Parameters Parameter Type Required? Example Description goal Integer Y 100 Total goal value http_link String Y groups.google.com/group/openei URL to which the meter will hyperlink. Note that the leading "http://" must be omitted. title String Y Google Group Members The goal's title. value Integer Y 25 Current value of progress against the goal. height Integer N (default=100) 150 Height of the meter image (in pixels). width Integer N (default=200) 300 Width of the meter image (in pixels). Example Output Google Group Members (goal: 100) Retrieved from "http://en.openei.org/w/index.php?title=Widget:GoalMeter&oldid=271157"

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Guam - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Guam - Net Metering Guam - Net Metering Guam - Net Metering < Back Eligibility Agricultural Commercial Industrial Institutional Nonprofit Residential Schools Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Wind Solar Home Weatherization Program Info Program Type Net Metering Provider Guam Energy Office Guam's Public Utilities Commission (PUC) reviewed net metering and interconnection during a regular meeting in February 2009 (Docket 08-10). Please contact the [http://www.guampuc.com/ Guam PUC] for the results of that docket review. In 2004, Guam enacted legislation requiring the Guam Power Authority (GPA) to allow net metering for customers with fuel cells, microturbines, wind energy, biomass, hydroelectric, solar energy or hybrid systems of these

162

Net Metering Rules (Arkansas) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Rules (Arkansas) Net Metering Rules (Arkansas) Net Metering Rules (Arkansas) < Back Eligibility Commercial Industrial Installer/Contractor Investor-Owned Utility Retail Supplier Rural Electric Cooperative Systems Integrator Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Arkansas Program Type Net Metering Provider Arkansas Public Service Commission The Net Metering Rules are promulgated under the authority of the Arkansas Public Service Commission. These rules are created to establish rules for net energy metering and interconnection. These rules are developed pursuant to the Arkansas Renewable Energy Development Act (Arkansas Code Annotated 23-18-603). These rules apply to all electric utilities.

163

A Million Meter Milestone | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

A Million Meter Milestone A Million Meter Milestone A Million Meter Milestone March 4, 2011 - 2:36pm Addthis To see what installing the 1 millionth meter looked like, check out this video. Don Macdonald Program Manager, Smart Grid Investment Grant Program What does this mean for me? Smart meters allow consumers to take personal control and ownership of her energy usage in a way not possible before. As program manager for the Department of Energy's Recovery Act funded Smart Grid Investment Grant (SGIG) program, I've had the pleasure of seeing SGIG reach several important milestones recently. Among the most notable has been the recent achievement of three million smart meters installed by SGIG recipients as of December 31, 2010. On February 23, 2011, along with my colleague Chris Irwin, I was in Houston, Texas where SGIG

164

Nonclassical dynamics induced by a quantum meter  

Science Journals Connector (OSTI)

Conventionally, the effect of measurements on a quantum system is assumed to introduce decoherence, which renders the system classical-like. We consider here a microscopic meter, that is, an auxiliary essentially quantum system whose state is measured repeatedly, and show that it can be employed to induce transitions from classical states into inherently quantumlike states. The meter state is assumed to be lost in the environment and we derive a non-Markovian master equation for the dynamic system in the case of nondemolition coupling to the meter; this equation can be cast in the form of an (Na)th-order differential equation in time, where Na is the dimension of the meter basis. We apply the approach to a harmonic oscillator coupled to a spin-12 meter and demonstrate how it can be used to engineer effective Hamiltonian evolution, subject to decoherence induced by the projective meter measurements.

J. Clausen; J. Salo; V. M. Akulin; S. Stenholm

2005-12-05T23:59:59.000Z

165

O&M Metering Guidance  

Broader source: Energy.gov (indexed) [DOE]

O&M and Metering Guidance O&M and Metering Guidance Ab Ream Ab.ream@ee.doe.gov Federal Utility Partnership Working Group October 2010, Rapid City SD 2 | FEDERAL ENERGY MANAGEMENT PROGRAM femp.energy.gov O&M and Metering Guidance FEMP Mission Statement "The Federal Energy Management Program facilitates the Federal government's implementation of sound, cost- effective energy management practices to enhance the nation's energy security and environmental stewardship" 3 | FEDERAL ENERGY MANAGEMENT PROGRAM femp.energy.gov O&M and Metering Guidance O&M Best Practice Guidance Release 3.0 - August 2010 General Updates Include:

166

Ellsworth Air Force Base Advanced Metering Project  

Broader source: Energy.gov [DOE]

Presentation covers the Ellsworth Air Force Base Advanced Metering project and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Providence, Rhode Island.

167

Advanced Metering Infrastructure Security Considerations | Department...  

Broader source: Energy.gov (indexed) [DOE]

Infrastructure Security Considerations The purpose of this report is to provide utilities implementing Advanced Metering Infrastructure (AMI) with the knowledge necessary to...

168

The Impact of Rate Design and Net Metering on the Bill Savings from  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The Impact of Rate Design and Net Metering on the Bill Savings from The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California Title The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California Publication Type Report Refereed Designation Unknown Year of Publication 2010 Authors Darghouth, Naïm, Galen L. Barbose, and Ryan H. Wiser Pagination 62 Date Published 04/2010 Publisher LBNL City Berkeley Keywords electricity markets and policy group, electricity rate design, energy analysis and environmental impacts department, net metering, photovoltaics Abstract Net metering has become a widespread policy in the U.S. for supporting distributed photovoltaics (PV) adoption.1 Though specific design details vary, net metering allows customers with PV to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption - in effect, compensating the PV generation at retail electricity rates (Rose et al. 2009). Though net metering has played an important role in jump-starting the PV market in the U.S., challenges to net metering policies have emerged in a number of states and contexts, and alternative compensation methods are under consideration. Moreover, one inherent feature of net metering is that the value of the utility bill savings it provides to customers with PV depends heavily on the structure of the underlying retail electricity rate, as well as on the characteristics of the customer and PV system. Consequently, the bill-savings value of net metering - and the impact of moving to alternative compensation mechanisms - can vary substantially from one customer to the next. For these reasons, it is important for policymakers and others that seek to support the development of distributed PV to understand both how the bill savings benefits of PV varies under net metering, and how the bill savings under net metering compares to savings associated with other possible compensation mechanisms. To advance this understanding, we analyze the bill savings from PV for residential customers of California's two largest electric utilities, Pacific Gas and Electric (PG&E) and Southern California Edison (SCE).3 The analysis is based on hourly load data from a sample of 215 residential customers located in the service territories of the two utilities, matched with simulated hourly PV production for the same time period based on data from the nearest of 73 weather stations in the state. We focus on these two utilities, both because we had ready access to a sample of load data for their residential customers, and because their service territories are the largest markets for residential PV in the country.

169

Assessment of Demand Response and Advanced Metering  

E-Print Network [OSTI]

#12;#12;2008 Assessment of Demand Response and Advanced Metering Staff Report Federal Energy metering penetration and potential peak load reduction from demand response have increased since 2006. Significant activity to promote demand response or to remove barriers to demand response occurred at the state

Tesfatsion, Leigh

170

Proton recoil scintillator neutron rem meter  

DOE Patents [OSTI]

A neutron rem meter utilizing proton recoil and thermal neutron scintillators to provide neutron detection and dose measurement. In using both fast scintillators and a thermal neutron scintillator the meter provides a wide range of sensitivity, uniform directional response, and uniform dose response. The scintillators output light to a photomultiplier tube that produces an electrical signal to an external neutron counter.

Olsher, Richard H. (Los Alamos, NM); Seagraves, David T. (Los Alamos, NM)

2003-01-01T23:59:59.000Z

171

Energy savings attributable to switching from master metering to individual metering of electricity  

SciTech Connect (OSTI)

This technical memo reviews and analyzes the published literature on electricity consumption by tenants in residential buildings with individual meters, compared with electricity consumption in residential buildings with master meters. An important finding is that energy savings of individual over master metering are strongly correlated with the price of electricity.

Nelson, S.H.

1981-01-01T23:59:59.000Z

172

Puerto Rico - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Puerto Rico - Net Metering Puerto Rico - Net Metering Puerto Rico - Net Metering < Back Eligibility Agricultural Commercial Industrial Institutional Local Government Multi-Family Residential Nonprofit Residential Schools State Government Savings Category Energy Sources Buying & Making Electricity Solar Wind Program Info Program Type Net Metering Provider Autoridad de Energía Electrica de Puerto Rico Puerto Rico enacted net-metering legislation in August 2007, allowing customers of Puerto Rico Electric Power Authority (PREPA) to use electricity generated by solar, wind or "other" renewable-energy resources to offset their electricity usage. This law applies to residential systems with a generating capacity of up to 25 kilowatts (kW) and non-residential systems up to one megawatt (MW) in capacity.*

173

Definition: Meter Communications Network | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Meter Communications Network Jump to: navigation, search Dictionary.png Meter Communications Network The communications infrastructure that supports two-way delivery of information between smart meters and data collectors or access points. This infrastructure can be wired or wireless, and can be owned by the utility or a third party service provider. This network is sometimes referred to as a "field area network".[1] Related Terms smart grid References ↑ https://www.smartgrid.gov/category/technology/meter_communications_network [[C Like Like You like this.Sign Up to see what your friends like. ategory: Smart Grid Definitions|Template:BASEPAGENAME]] Retrieved from "http://en.openei.org/w/index.php?title=Definition:Meter_Communications_Network&oldid=493063"

174

EIA-930 Hourly and Daily Balancing ...  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

not change from day-to-day or hour-to-hour, as specified in the immediately preceding section. For each hour of the day, hourly integrated demand is to be posted within ten...

175

Energy Sub-Metering Equipment and Applications  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Energy Sub-Metering Equipment and Applications Energy Sub-Metering Equipment and Applications Speaker(s): Sim Gurewitz Date: July 24, 2008 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Paul Mathew This talk will address the following topics:Submetering basics: What is it? How does a submeter work?How to obtain a finer level of energy information within the buildingApplications: Who submeters and why?LEED NC/EB/CS and submetering / Energy & Atmosphere pointsSubmetering equipment: gas, electric, water, steam, CW Btu and HHW BtuHow to install equipment without scheduling an outageLoad Control option for automated load shedding and peak shavingWireless submeters and communication options / integration to EMS-BMCSAutomatic remote meter reading and cost allocation softwarePutting it all together into a metering SYSTEM: read from anywhere, IP

176

Algorithms for revenue metering and their evaluation  

E-Print Network [OSTI]

systems, which include, among other functions, the remote measurement systems. The new generation of meters is capable of calculating almost any definition for the power components. The problem now is which definitions are going to be implemented...

Martinez-Lagunes, Rodrigo

2012-06-07T23:59:59.000Z

177

June 25 Webinar to Explore Net Metering  

Broader source: Energy.gov [DOE]

Register for the Net Metering webinar, which will be held on Wednesday, June 25, 2014, from 11 a.m. to 12:30 p.m. Mountain time.

178

Portable Liquid Flow Metering for Energy Conservation Programs  

E-Print Network [OSTI]

meters to measure liquids. This paper reviews the principles of ultrasonic flow meters. Applications and costs of ultrasonic versus orifice flow meters are important to consider in energy audits. A discussion follows on 'how' and 'where' to use...

Miles, F. J.

1982-01-01T23:59:59.000Z

179

Working With Your Utility to Obtain Metering Services  

Broader source: Energy.gov [DOE]

Presentationgiven at the Spring 2013 Federal Utility Partnership Working Group (FUPWG) meetingcovers the government metering requirement, the U.S. Department of Defense (DoD) metering directive, and customer metering services available from utilities.

180

You Can Justify Meters for Your Energy Conservation Program  

E-Print Network [OSTI]

Meters don't save energy' This statement has often concluded a meeting or terminated a budget request leaving the metering proponent feeling frustrated. Such a statement is technically correct when meters are evaluated in the same way as equipment...

Rusnak, J. J.

1981-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Use Meters to Put Teeth into Your Conservation Programs  

E-Print Network [OSTI]

is effective flow metering, but that is a difficult job even in more traditional applications. The problem is compounded by the fact that traditional metering concepts are inadequate for the unique problems presented by retro-metering for in...

Hayes, J. W.; Rusnak, J. J.

1980-01-01T23:59:59.000Z

182

NERSC Carver Hours Used Report  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Carver Hours Carver Hours Used Carver Hours Used Hopper Usage Chart Hopper Usage Chart Date Hours Used (in millions) Percent of Maximum Possible (24 hours/day) 01/05/2014 170.00 89.35 01/04/2014 174.38 91.65 01/03/2014 174.15 91.53 01/02/2014 179.72 94.45 01/01/2014 173.76 91.32 12/31/2013 172.25 90.53 12/30/2013 169.62 89.14 12/29/2013 164.72 86.57 12/28/2013 177.92 93.51 12/27/2013 171.61 90.19 12/26/2013 172.74 90.79 12/25/2013 172.13 90.46 12/24/2013 173.48 91.18 12/23/2013 174.92 91.93 12/22/2013 175.26 92.11 12/21/2013 173.58 91.23 12/20/2013 174.50 91.71 12/19/2013 170.02 89.36 12/18/2013 178.25 93.68 12/17/2013 176.17 92.59 12/16/2013 162.03 85.16 12/15/2013 157.09 82.56 12/14/2013 173.40 91.13 12/13/2013 185.02 97.24 12/12/2013 150.91 79.31 12/11/2013 31.67 16.64 12/10/2013 92.44 48.58

183

2,279 METERS BOUYANT POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,279 METERS BOUYANT POLYOLEFIN MOORING LINE 10 METERS NYLON STIFFENER 3/4" SAS .5 M 1/2" CHAIN 5 SPLICE 17" GLASS BALL FLOATS 5/8" SAS 5/8" SAS 3 TON SWIVEL ACOUSTIC RELEASE 20 METERS 1 1/8" NYLON 5/8" SAS 5/8" SAS 3/4" SAS .5 METER CHAIN 5/8" SAS 2 METER CHAIN .5 METER CHAIN 3/4" SAS WITH BUSHING TC

184

Metering Best Practices: A Guide to Achieving Utility Resource Efficiency  

Broader source: Energy.gov [DOE]

Guide describes information about energy and resource metering at federal facilities, including metering requirements under the Energy Policy Act of 2005.

185

Demand Response and Smart Metering Policy Actions Since the Energy...  

Broader source: Energy.gov (indexed) [DOE]

Demand Response and Smart Metering Policy Actions Since the Energy Policy Act of 2005: A Summary for State Officials Demand Response and Smart Metering Policy Actions Since the...

186

Fuel Quality and Metering: Current Status and Future Needs |...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Fuel Quality and Metering: Current Status and Future Needs Fuel Quality and Metering: Current Status and Future Needs These slides were presented at the Onboard Storage Tank...

187

,,,,,"Capacity MW",,,,,"Number of Meters",,,,,"Energy Sold Back...  

U.S. Energy Information Administration (EIA) Indexed Site

Other",,,"All Technologies" ,,,,,"Capacity MW",,,,,"Number of Meters",,,,,"Energy Sold Back MWh",,,,,"Capacity MW",,,,,"Number of Meters",,,,,"Energy Sold Back...

188

Location and Hours | ornl.gov  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Location and Hours Location The ORNL Research Library is located off the central corridor of Bldg. 4500N on the main ORNL campus. Hours The library is open 24 hours, seven days a...

189

hourly data | OpenEI  

Open Energy Info (EERE)

data data Dataset Summary Description (Abstract): Each data file is a set of hourly values of solar radiation and meteorological elements for a 1-year period. Solar radiation is modeled using the NREL METSTAT model, with surface observed cloud cover being the principal model input. Each container file contains up to 30 yearly files for one station, plus the Typical Meteorological Year (TMY) file for the selected station, plus documentation files and a TMY data reader file for use with Microsoft Excel. Source U.S. National Renewable Energy Laboratory (NREL) Date Released May 03rd, 2005 (9 years ago) Date Updated November 01st, 2007 (7 years ago) Keywords DNI GHI hourly data NREL solar Sri Lanka SWERA TILT TMY UNEP Data application/zip icon Download TMY data (zip, 67.5 MiB)

190

Guidance for Electric Metering in Federal Buildings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

blank. blank. Executive Summary The Energy Policy Act of 2005 (EPAct 2005), Section 103, requires all federal agencies to install metering and advanced metering where found to be cost-effective, according to guidelines developed by the Department of Energy (DOE), in consultation with a number of interest groups. DOE has met with representatives from the metering industry, the utility industry, energy services industry, energy efficiency industry, energy effi- ciency advocacy organizations, national laboratories, universities, and federal facility managers to develop the guidelines set forth in this document. There were several areas in the language of Section 103 that required some level of clarification prior to finaliz- ing these guidelines, as follows: * DOE has determined that Section 103 pertains to

191

An Angstrom-long Meter Stick  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Physical Review Focus Physical Review Focus An Angstrom-long Meter Stick When you want to measure the width of a window frame or the height of your growing child, it helps to have a good meter stick. But on the atomic scale, accurate measurements are harder to come by. In the 17 July PRL, a team reports a potential new standard of length for short distances based on radiation from the excited nuclei of iron atoms. Further improvements may make this standard an important tool for probing the structure of matter, where physicists must gauge the separations between nuclei with an accuracy of millionths of an angstrom. Figure by Robert Irion depicting Mossbauer effect. by Robert Irion The meter, once defined as the gap between two etchings on a metal bar in Paris, is now set as the distance that light from a helium-neon laser

192

Hour-by-Hour Cost Modeling of Optimized Central Wind-Based Water...  

Broader source: Energy.gov (indexed) [DOE]

Hour-by-Hour Cost Modeling of Optimized Central Wind-Based Water Electrolysis Production Hour-by-Hour Cost Modeling of Optimized Central Wind-Based Water Electrolysis Production...

193

Liquid metal Flow Meter - Final Report  

SciTech Connect (OSTI)

Measuring the flow of liquid metal presents serious challenges. Current commercially-available flow meters use ultrasonic, electromagnetic, and other technologies to measure flow, but are inadequate for liquid metal flow measurement because of the high temperatures required by most liquid metals. As a result of the reactivity and high temperatures of most liquid metals, corrosion and leakage become very serious safety concerns. The purpose of this project is to develop a flow meter for Lockheed Martin that measures the flow rate of molten metal in a conduit.

Andersen C, Hoogendoom S, Hudson B, Prince J, Teichert K, Wood J, Chase K

2007-01-30T23:59:59.000Z

194

INSTRUCTION MANUAL digital pH/mV meter  

E-Print Network [OSTI]

INSTRUCTION MANUAL model 701A digital pH/mV meter /r^ ORION RESEARCH #12;contents Introduction 1 701A digital pH/mV meter is the ideal meter for all research and precision measurements with pH and chemical sensing electrodes. In both the absolute and relative mV modes, the meter covers a range of ± 1999

Kleinfeld, David

195

Definition: Kilowatt-hour | Open Energy Information  

Open Energy Info (EERE)

Kilowatt-hour Kilowatt-hour Jump to: navigation, search Dictionary.png Kilowatt-hour A unit of measure for energy, typically applied to electricity usage; equal to the amount of energy used at a rate of 1,000 watts over the course of one hour. One kWh is equivalent to 3,412 Btu, or 3,600 kJ.[1][2] View on Wikipedia Wikipedia Definition The kilowatt hour, or kilowatt-hour, (symbol kW·h, kW h or kWh) is a unit of energy equal to 1000 watt hours or 3.6 megajoules. For constant power, energy in watt hours is the product of power in watts and time in hours. The kilowatt hour is most commonly known as a billing unit for energy delivered to consumers by electric utilities. Also Known As kWh Related Terms British thermal unit, Electricity, Energy, Kilowatt, energy, electricity generation

196

Laser Power Meter Large, bright, backlit LCD  

E-Print Network [OSTI]

Laser Power Meter FEATURES · Large, bright, backlit LCD display · Digital accuracy with analog-like movement for laser tuning · Works with thermopile and optical sensors · Intuitive button-driven user COMPATIBILITY · PowerMax® thermal sensors · Optical sensors FieldMaxII-TO Coherent Laser Measurement and Control

Woodall, Jerry M.

197

Monitoring Advanced Metering Infrastructures with Amilyzer  

E-Print Network [OSTI]

-way communications between smart meters and utility control centers. They are a key component of the smart grid mechanisms are part of communication standards such as the ANSI #12;C12.22. While those protective measures detecting intrusions in IT environments have been developed and evaluated. Through the Trustworthy Cyber

Sanders, William H.

199

KVP meter errors induced by plastic wrap  

SciTech Connect (OSTI)

The purpose of this study was to determine whether erroneous kVp meter readings, induced by plastic wrap, affected the actual kVp (output) of a dental X-ray machine. To evaluate the effect of plastic wrap on dental X-ray machine kVp meters, a radiation output device was used to measure output in mR/ma.s. An intraoral dental X-ray unit (S.S. White Model {number sign}90W) was used to make the exposures. First, the kVp meter was not covered with plastic wrap and output readings were recorded at various kVp settings with the milliamperage and time held constant. Secondly, the same kVp settings were selected before the plastic wrap was placed. Milliamperage and time were again held to the same constant. The X-ray console was then covered with plastic wrap prior to measuring the output for each kVp. The wrap possessed a static charge. This charge induced erroneous kVp meter readings. Out-put readings at the various induced kVp settings were then recorded. A kVp of 50 with no wrap present resulted in the same output as a kVp of 50 induced to read 40 or 60 kVp by the presence of wrap. Similar results were obtained at other kVp settings. This indicates that the plastic wrap influences only the kVp meter needle and not the actual kilovoltage of the X-ray machine. Dental X-ray machine operators should select kVp meter readings prior to placing plastic wrap and should not adjust initial settings if the meter is deflected later by the presence of wrap. The use of such a procedure will result in proper exposures, fewer retakes, and less patient radiation. If plastic wrap leads to consistent exposure errors, clinicians may wish to use a 0.5% sodium hypochlorite disinfectant as an alternative to the barrier technique.

Jefferies, D.; Morris, J.W.; White, V.P. (Southern Illinois Univ., Carbondale (USA))

1991-02-01T23:59:59.000Z

200

Frequent-Interval Seismic CPTu  

Broader source: Energy.gov (indexed) [DOE]

Frequent-Interval Frequent-Interval Seismic CPTu D. Bruce Nothdurft, MSCE, PE, PG SRS Geotechnical Engineering Department Savannah River Nuclear Solutions Alec V. McGillivray, PhD, PE Geotechnical Consultant Brent J. Gutierrez, PhD, PE NPH Engineering Manager, DOE-SR Motivation  The seismic piezocone penetration test (SCPTu) utilized at SRS because it provides rapid and thorough site characterization.  Evaluation of non-linear soil behavior...  detailed stratigraphy  small-strain velocity measurements  large-strain non-seismic measurements  Depth scale disparity  large-strain non-seismic measurements nearly continuous with depth  small-strain velocity measurements over 1 m depth intervals. 2 October 25-26, 2011 DOE NPH Conference

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Constancy of built-in luminance meter measurements in diagnostic displays  

SciTech Connect (OSTI)

Purpose: Liquid crystal displays used to interpret medical images are often equipped with built-in luminance meters to evaluate luminance response and Grayscale Standard Display Function conformance. This work evaluates agreement between luminance reported by the built-in meters and external measurements. Methods: The white level luminance was measured using a built-in meter and an external meter for 93 primary review workstations (Models MFGD 3420 and MDCG 3120-CB) with between 117 and 49?336 backlight hours (BLH). Measured luminance values were compared viat-test for displays with less than 25?000 BLH and those with more than 25?000 BLH. Bias between meters was also evaluated. Changes in luminance uniformity with increasing backlight hours were explored by determining the maximum luminance deviation (MLD) for subsets of these displays with less than 800 BLH and greater than 35?000 BLH. Results: The mean difference between built-in and external luminance measurements was 5.84% and 38.92% for displays with less than 25?000 and greater than 25?000 BLH, respectively, with a statistically significant difference in the means (p < 0.001). For displays with low BLH, a statistically significant bias was observed (p < 0.001) between built-in and external measurements. A high degree of correlation was observed between measurements made with two separate external meters (r = 0.999). The mean MLD was 9.5% and 11.2% for MDCG 3120-CB displays with less than 800 and greater than 35?000 BLH, respectively. The difference in the mean values was not statistically significant (p < 0.001). Conclusions: Disagreement between the white level luminance measured using the built-in and external meter increased with BLH. Consequently, reliance on values reported by the built-in luminance meter may result in a reduction in image contrast with time. Recommendations have been proposed regarding luminance response testing and corrective action for failing displays.

Silosky, M., E-mail: michael.silosky@ucdenver.edu; Marsh, R. M. [Department of Radiology, University of Colorado, School of Medicine Aurora, Colorado 80045 (United States)] [Department of Radiology, University of Colorado, School of Medicine Aurora, Colorado 80045 (United States)

2013-12-15T23:59:59.000Z

202

The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California  

SciTech Connect (OSTI)

Net metering has become a widespread policy in the U.S. for supporting distributed photovoltaics (PV) adoption. Though specific design details vary, net metering allows customers with PV to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption - in effect, compensating the PV generation at retail electricity rates (Rose et al. 2009). While net metering has played an important role in jump-starting the residential PV market in the U.S., challenges to net metering policies have emerged in a number of states and contexts, and alternative compensation methods are under consideration. Moreover, one inherent feature of net metering is that the value of the utility bill savings it provides to customers with PV depends heavily on the structure of the underlying retail electricity rate, as well as on the characteristics of the customer and PV system. Consequently, the value of net metering - and the impact of moving to alternative compensation mechanisms - can vary substantially from one customer to the next. For these reasons, it is important for policymakers and others that seek to support the development of distributed PV to understand both how the bill savings varies under net metering, and how the bill savings under net metering compares to other possible compensation mechanisms. To advance this understanding, we analyze the bill savings from PV for residential customers of California's two largest electric utilities, Pacific Gas and Electric (PG&E) and Southern California Edison (SCE). The analysis is based on hourly load data from a sample of 215 residential customers located in the service territories of the two utilities, matched with simulated hourly PV production for the same time period based on data from the nearest of 73 weather stations in the state.

Darghouth, Naim; Barbose, Galen; Wiser, Ryan

2010-03-30T23:59:59.000Z

203

Frequent-Interval Seismic CPTu  

Broader source: Energy.gov [DOE]

Frequent-Interval Seismic CPTu D. Bruce Nothdurft, MSCE, PE, PG SRS Geotechnical Engineering Department Savannah River Nuclear Solutions Alec V. McGillivray, PhD, PE Geotechnical Consultant Brent J. Gutierrez, PhD, PE NPH Engineering Manager, DOE-SR

204

Upgrading of Traditional Electric Meter into Wireless Electric Meter Using ZigBee Technology  

Science Journals Connector (OSTI)

Since the electric generating, distributing and marketing has been possible; the Electric Meter was introduced and developed along the years, but never like this time. The digital technology, the wireless comm...

Berhanu Regassa; Ana Vernica Medina; Isabel M. Gmez; Octavio Rivera

2012-01-01T23:59:59.000Z

205

2010 Assessment of Demand Response and Advanced Metering - Staff Report |  

Broader source: Energy.gov (indexed) [DOE]

Assessment of Demand Response and Advanced Metering - Staff Assessment of Demand Response and Advanced Metering - Staff Report 2010 Assessment of Demand Response and Advanced Metering - Staff Report 2010 Assessment of Demand Response and Advanced Metering - Staff Report. The Federal Energy Regulatory Commission's 2010 Demand Response and Advanced Metering Survey (2010 FERC Survey, covering calendar year 2009) indicates that advanced metering penetration (i.e., the fraction of all installed meters that are advanced meters) reached approximately 8.7 percent in the United States, compared to approximately 4.7 percent in the 2008 FERC Survey (covering calendar year 2007). The upper Midwest, West and Texas have advanced meter penetrations exceeding 13 percent. As in previous surveys, electric cooperatives have the largest penetration, nearly 25 percent, among

206

2010 Assessment of Demand Response and Advanced Metering - Staff Report |  

Broader source: Energy.gov (indexed) [DOE]

2010 Assessment of Demand Response and Advanced Metering - Staff 2010 Assessment of Demand Response and Advanced Metering - Staff Report 2010 Assessment of Demand Response and Advanced Metering - Staff Report 2010 Assessment of Demand Response and Advanced Metering - Staff Report. The Federal Energy Regulatory Commission's 2010 Demand Response and Advanced Metering Survey (2010 FERC Survey, covering calendar year 2009) indicates that advanced metering penetration (i.e., the fraction of all installed meters that are advanced meters) reached approximately 8.7 percent in the United States, compared to approximately 4.7 percent in the 2008 FERC Survey (covering calendar year 2007). The upper Midwest, West and Texas have advanced meter penetrations exceeding 13 percent. As in previous surveys, electric cooperatives have the largest penetration, nearly 25 percent, among

207

Ellsworth Air Force Base Advanced Metering Project  

Broader source: Energy.gov (indexed) [DOE]

Ellsworth Air Force Base Ellsworth Air Force Base Advanced Metering Project A Partnership between Ellsworth AFB and MDU Resources Group, Inc. to install advanced metering on all large buildings on EAFB  Based in Bismarck, North Dakota  Celebrated our 85 th year in 2009  NYSE - MDU for over 60 years  Over $4B market cap  Fortune 500 Company  Member of the S&P MidCap 400 Index  Over 8,000 employees in 44 states  Business Lines:  Energy  Utility Resources  Construction Materials  Construction Materials  Energy  Oil and Gas Production  Utility Resources  Natural Gas Pipelines  Construction Services  Electric / Natural Gas Utilities  Utility Resources  Montana - Dakota Utilities Co.  Cascade Natural Gas Co.  Intermountain Gas Corporation

208

Resonant speed meter for gravitational wave detection  

E-Print Network [OSTI]

Gravitational-wave detectors have been well developed and operated with high sensitivity. However, they still suffer from mirror displacement noise. In this paper, we propose a resonant speed meter, as a displacement noise-canceled configuration based on a ring-shaped synchronous recycling interferometer. The remarkable feature of this interferometer is that, at certain frequencies, gravitational-wave signals are amplified, while displacement noises are not.

Atsushi Nishizawa; Seiji Kawamura; Masa-aki Sakagami

2008-05-01T23:59:59.000Z

209

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Honduras from SUNY Honduras from SUNY Dataset Summary Description (Abstract): Zip file contains year-site specific files including time series of global, direct and diffuse irradiance (Purpose): The time series are useful for performing site specific simulation of customized solar energy systems (Supplemental Information): Each file's name identifies year and location, by listing Country_City_latitude-longitude_year, e.g., EL_SALVADOR_San_Salvador_13.75-89.15_98.out is for the city of San Salvador, in El Salvador, latitude 13.75 degrees, longitude -89.15 degrees, year 1998. The content of each file includes A one line header, listing latitude, longitude and ground elevation in meters,Hourly records including, year, month, day, time (GMT), global irradiance, direct irradiance and

210

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Nicaragua from SUNY Nicaragua from SUNY Dataset Summary Description (Abstract): Zip file contains year-site specific files including time series of global, direct and diffuse irradiance (Purpose): The time series are useful for performing site specific simulation of customized solar energy systems (Supplemental Information): Each file's name identifies year and location, by listing Country_City_latitude-longitude_year, e.g., EL_SALVADOR_San_Salvador_13.75-89.15_98.out is for the city of San Salvador, in El Salvador, latitude 13.75 degrees, longitude -89.15 degrees, year 1998. The content of each file includes A one line header, listing latitude, longitude and ground elevation in meters,Hourly records including, year, month, day, time (GMT), global irradiance, direct irradiance and

211

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Guatemala from SUNY Guatemala from SUNY Dataset Summary Description (Abstract): Zip file contains year-site specific files including time series of global, direct and diffuse irradiance (Purpose): The time series are useful for performing site specific simulation of customized solar energy systems (Supplemental Information): Each file's name identifies year and location, by listing Country_City_latitude-longitude_year, e.g., EL_SALVADOR_San_Salvador_13.75-89.15_98.out is for the city of San Salvador, in El Salvador, latitude 13.75 degrees, longitude -89.15 degrees, year 1998. The content of each file includes A one line header, listing latitude, longitude and ground elevation in meters,Hourly records including, year, month, day, time (GMT), global irradiance, direct irradiance and

212

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Cuba sites from SUNY Cuba sites from SUNY Dataset Summary Description (Abstract): Zip file contains year-site specific files including time series of global, direct and diffuse irradiance (Purpose): The time series are useful for performing site specific simulation of customized solar energy systems (Supplemental Information): Each file's name identifies year and location, by listing Country_City_latitude-longitude_year, e.g., EL_SALVADOR_San_Salvador_13.75-89.15_98.out is for the city of San Salvador, in El Salvador, latitude 13.75 degrees, longitude -89.15 degrees, year 1998. The content of each file includes A one line header, listing latitude, longitude and ground elevation in meters,Hourly records including, year, month, day, time (GMT), global irradiance, direct irradiance and

213

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

El Salvador sites from SUNY El Salvador sites from SUNY Dataset Summary Description (Abstract): Zip file contains year-site specific files including time series of global, direct and diffuse irradiance (Purpose): The time series are useful for performing site specific simulation of customized solar energy systems (Supplemental Information): Each file's name identifies year and location, by listing Country_City_latitude-longitude_year, e.g., EL_SALVADOR_San_Salvador_13.75-89.15_98.out is for the city of San Salvador, in El Salvador, latitude 13.75 degrees, longitude -89.15 degrees, year 1998. The content of each file includes A one line header, listing latitude, longitude and ground elevation in meters,Hourly records including, year, month, day, time (GMT), global irradiance, direct irradiance and

214

Nevada Smart Meter Program Launches | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Nevada Smart Meter Program Launches Nevada Smart Meter Program Launches Nevada Smart Meter Program Launches October 18, 2010 - 11:30am Addthis Workers began installing smart meters for NV Energy's smart meter project three weeks ago. The project is expected to create 200 jobs, according to NV Energy. | Photo courtesy of NV Energy Workers began installing smart meters for NV Energy's smart meter project three weeks ago. The project is expected to create 200 jobs, according to NV Energy. | Photo courtesy of NV Energy Paul Lester Communications Specialist, Office of Energy Efficiency and Renewable Energy What does this mean for me? These meters will not only allow residents to lower their energy bills by providing them information on their energy use, but by reducing operating costs, the utility expects to pass on these savings as well.

215

City of St. George - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

City of St. George - Net Metering City of St. George - Net Metering City of St. George - Net Metering < Back Eligibility Commercial General Public/Consumer Residential Savings Category Solar Buying & Making Electricity Program Info State Utah Program Type Net Metering Provider City of St. George The St. George City Council adopted a [http://www.sgcity.org/wp/power/NetMeteringPolicy.pdf net-metering program for area utilities], including interconnection procedures, in October 2005.* The interconnection procedures include different requirements, based on system size, for systems up to 10 megawatts (MW). Net metering is available to residential and commercial customers that generate electricity using photovoltaic (PV) systems. The net metering agreements currently available on the utility's web site only pertain to

216

Two-Meter Temperature Surveys for Geothermal Exploration Project...  

Open Energy Info (EERE)

Two-Meter Temperature Surveys for Geothermal Exploration Project at NAS Fallon Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: Two-Meter...

217

WINDExchange: Offshore 90-Meter Wind Maps and Wind Resource Potential  

Wind Powering America (EERE)

Offshore 90-Meter Wind Maps and Wind Resource Potential The U.S. Department of Energy provides 90-meter (m) height, high-resolution wind maps and estimates of the total offshore...

218

WINDExchange: Community-Scale 50-Meter Wind Maps  

Wind Powering America (EERE)

Community-Scale 50-Meter Wind Maps The U.S. Department of Energy provides 50-meter (m) height, high-resolution wind resource maps for most of the states and territories of Puerto...

219

WINDExchange: Residential-Scale 30-Meter Wind Maps  

Wind Powering America (EERE)

Residential-Scale 30-Meter Wind Maps The U.S. Department of Energy provides 30-meter (m) height, high-resolution wind resource maps for the United States. Businesses, farms, and...

220

Borehole gravity meter survey in drill hole USW G-4, Yucca Mountain Area, Nye County, Nevada  

SciTech Connect (OSTI)

Drill hole USW G-4 was logged with the US Geological Survey borehole gravity meter (BHGM) BH-6 as part of a detailed study of the lithostratigraphic units penetrated by this hole. Because the BHGM measures a larger volume of rock than the conventional gamma-gamma density tool, it provides an independent and more accurate measurement of the in situ average bulk density of thick lithologic units. USW G-4 is an especially important hole because of its proximity to the proposed exploratory shaft at Yucca Mountain. The BHGM data were reduced to interval densities using a free-air gradient (F) of 0.3083 mGal./m (0.09397 mGal/ft) measured at the drill site. The interval densities were further improved by employing an instrument correction factor of 1.00226. This factor was determined from measurements obtained by taking gravity meter BH-6 over the Charleston Peak calibration loop. The interval density data reported herein, should be helpful for planning the construction of the proposed shaft.

Healey, D.L.; Clutsom, F.G.; Glover, D.A.

1986-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Shared Signals: Using Existing Facility Meters for Energy Savings Verification  

E-Print Network [OSTI]

energy conservation projects. (2) These guidelines provide monitoring and verification options that have different levels of accuracy and cost. They are specifically designed for energy savings performance contracts and are designed to provide... with a fair degree of accuracy. The costs of using existing meters are often not as clear. Obviously, if an existing meter is used, the costs of purchasing new metering equipment is avoided. However, using an existing meter is not free of costs...

McBride, J. R.; Bohmer, C. J.; Price, S. D.; Carlson, K.; Lopez, J.

222

Calibration of Predicted Hourly Zone-Level Supply Air Flows with Measurements  

E-Print Network [OSTI]

the chemical composition, then sends a signal to the control system to increase the ventilation rate, if necessary. This system cannot be modeled in eQuest. The null hypothesis H0 is true only if the t-value is less than tcritical; if t-value is greater..., daily and monthly calibration analysis: CV-RMSE[%] vs. t-test CV-RMSE [%] Zone Interval Time step t t,cr 2.1 NE Summer Hourly 18.8 Daily 9.5 Monthly 4.2 3 days Hourly 24.2 2.4 SW Summer Hourly 28.4 Daily 12.7 Monthly 4...

Mihai, A.; Zmeureanu, R.

2013-01-01T23:59:59.000Z

223

SmartD: smart meter data analytics dashboard  

Science Journals Connector (OSTI)

The ability of smart meters to communicate energy consumption data in (near) real-time enables data analytics for novel applications, such as pervasive demand response, personalized energy feedback, outage management, and theft detection. Smart meter ... Keywords: energy consumption analysis, smart meters, visualization

Aylin Jarrah Nezhad, Tri Kurniawan Wijaya, Matteo Vasirani, Karl Aberer

2014-06-01T23:59:59.000Z

224

RIS-M-2254 ON A RADIOCHROMIC DYE DOSE METER  

E-Print Network [OSTI]

RIS?-M-2254 ON A RADIOCHROMIC DYE DOSE METER Arne Miller and William L. McLaughlin Abstract. Radiochromic dye dose meters made of polyvinyl butyral (PVB) with hexa(hydroxyethyl)pararosaniline cyanide (HPR results and outlines plans for further research on this dose meter. Currently the response is found

225

ONE GEV BEAM ACCELERATION IN A ONE METER LONG  

E-Print Network [OSTI]

ONE GEV BEAM ACCELERATION IN A ONE METER LONG PLASMA CELL A Proposal to the Stanford Linear. A single SLC bunch is used to both induce wakefields in the one meter long plasma and to witness that are needed to apply high-gradient plasma wakefield acceleration to large scale accelerators. The one meter

226

Model 1918-C Hand-held Optical Meter  

E-Print Network [OSTI]

Model 1918-C Hand-held Optical Meter Start Up Guide #12;Start Up Guide 1 First printing 2006 © 2006, including safety precautions and start up procedures, needed to get your new optical meter up and running the use and operation of the optical meter is included in the complete User's Manual. The complete User

Kleinfeld, David

227

Math for Poets and Drummers The Mathematics of Meter  

E-Print Network [OSTI]

Math for Poets and Drummers The Mathematics of Meter Rachel Hall Saint Joseph's University 5600 a number of problems that are explored in class. In English and Spanish, the rhythm, or meter, of a piece- speare are written in the meter called iambic pentameter: five pairs of alternating unstressed

Hall, Rachel W.

228

Arnold Schwarzenegger TIME-OF-USE WATER METER EFFECTS  

E-Print Network [OSTI]

Arnold Schwarzenegger Governor TIME-OF-USE WATER METER EFFECTS ON CUSTOMER WATER USE; Master Meter Ed Amelung; Southern California Edison Company ­ Matt Garcia, Curtis DeWoody, and James · Transportation TimeofUse Water Meter Impacts on Customer Water Use is the final report for the project 500 07022

229

Weak measurements with a qubit meter  

E-Print Network [OSTI]

We derive schemes to measure the so-called weak values of quantum system observables by coupling of the system to a qubit meter system. We highlight, in particular, the meaning of the imaginary part of the weak values, and show how it can be measured directly on equal footing with the real part of the weak value. We present compact expressions for the weak value of single qubit observables and of product observables on qubit pairs. Experimental studies of the results are suggested with cold trapped ions.

Shengjun Wu; Klaus Mlmer

2009-11-13T23:59:59.000Z

230

Assessment of Interval Data and Their Potential Application to Residential Electricity End-Use Modeling, An  

Reports and Publications (EIA)

The Energy Information Administration (EIA) is investigating the potential benefits of incorporating interval electricity data into its residential energy end use models. This includes interval smart meter and submeter data from utility assets and systems. It is expected that these data will play a significant role in informing residential energy efficiency policies in the future. Therefore, a long-term strategy for improving the RECS end-use models will not be complete without an investigation of the current state of affairs of submeter data, including their potential for use in the context of residential building energy modeling.

2015-01-01T23:59:59.000Z

231

Long Island Power Authority - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Long Island Power Authority - Net Metering < Back Eligibility Agricultural Commercial Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Wind Solar Program Info State New York Program Type Net Metering Provider Long Island Power Authority : Note: In October 2012 the LIPA Board of Trustees adopted changes to the utility's net metering tariff that permit remote net metering for non-residential solar and wind energy systems, and farm-based biogas and wind energy systems. It also adopted a measure to increase the aggregate net metering cap for solar, agricultural biogas, residential micro-CHP and

232

Rocky Mountain Power - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Rocky Mountain Power - Net Metering Rocky Mountain Power - Net Metering Rocky Mountain Power - Net Metering < Back Eligibility Agricultural Commercial Fed. Government Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Idaho Program Type Net Metering Provider Rocky Mountain Power Idaho does not have a statewide net-metering policy. However, each of the state's three investor-owned utilities -- Avista Utilities, Idaho Power and Rocky Mountain Power -- has a net-metering tariff on file with the Idaho Public Utilities Commission (PUC). The framework of the utilities' net-metering programs is similar, in that each utility: (1) offers net

233

Austin Energy - Net Metering (Texas) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Austin Energy - Net Metering (Texas) Austin Energy - Net Metering (Texas) Austin Energy - Net Metering (Texas) < Back Eligibility Commercial Savings Category Bioenergy Buying & Making Electricity Solar Home Weatherization Water Wind Program Info State Texas Program Type Net Metering Provider Austin Energy Austin Energy, the municipal utility of Austin Texas, offers net metering for renewable energy systems up to 20 kilowatts (kW) to its non-residential retail electricity customers. The definition of renewable includes solar*, wind, geothermal, hydroelectric, wave and tidal energy, biomass, and biomass-based waste products, including landfill gas. Systems must be used primarily to offset a portion or all of a customer's on-site electric load. Metering is accomplished using a single meter capable of registering the

234

Montana Electric Cooperatives - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Electric Cooperatives - Net Metering Electric Cooperatives - Net Metering Montana Electric Cooperatives - Net Metering < Back Eligibility Commercial Residential Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Solar Home Weatherization Wind Program Info State Montana Program Type Net Metering Provider Montana Electric Cooperatives' Association The Montana Electric Cooperatives' Association (MECA) adopted model interconnection guidelines in 2001 and a revised net-metering policy in September 2008. Net metering is available in whole or part by most of the 26 electric cooperatives in Montana. A map of the service areas of each of member cooperative is available on the MECA web site. To determine if a specific cooperative offers net metering, view the MECA

235

Definition: Meter Data Management System | Open Energy Information  

Open Energy Info (EERE)

System System Jump to: navigation, search Dictionary.png Meter Data Management System A meter data management system (MDMS) collects and stores meter data from a head-end system and processes that meter data into information that can be used by other utility applications including billing, customer information systems, and outage management systems. The MDMS is a key resource for managing large quantities of meter data.[1] Related Terms system, outage management system References ↑ https://www.smartgrid.gov/category/technology/meter_data_management_system [[Ca LikeLike UnlikeLike You like this.Sign Up to see what your friends like. tegory: Smart Grid Definitionssmart grid,smart grid, |Template:BASEPAGENAME]]smart grid,smart grid, Retrieved from "http://en.openei.org/w/index.php?title=Definition:Meter_Data_Management_System&oldid=50258

236

Washington City Power - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Washington City Power - Net Metering Washington City Power - Net Metering Washington City Power - Net Metering < Back Eligibility General Public/Consumer Savings Category Solar Buying & Making Electricity Wind Program Info State Utah Program Type Net Metering Provider Washington City Washington City adopted a net-metering program, including interconnection procedures, in January 2008.* Net metering is available to residential and commercial customers that generate electricity using photovoltaic (PV) systems or wind-energy systems up to 10 kilowatts (kW) in capacity. At the customer's expense, the municipal utility will provide a single, bidirectional meter to measure the in-flow and out-flow of electricity at the customer's home. Systems are restricted to being sized to provide no more than 120% of the historic maximum monthly energy consumption of the

237

Farmington Electric Utility System - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Farmington Electric Utility System - Net Metering Farmington Electric Utility System - Net Metering Farmington Electric Utility System - Net Metering < Back Eligibility Residential Savings Category Energy Sources Buying & Making Electricity Solar Home Weatherization Water Wind Program Info State New Mexico Program Type Net Metering Provider Farmington Electric Utility System Net metering rules developed by the New Mexico Public Regulation Commission (PRC) apply to the state's investor-owned utilities and electric cooperatives. Municipal utilities, which are not regulated by the commission, are exempt from the PRC rules but authorized to develop their own net metering programs. Farmington Electric, a municipal utility, offers net metering to residential customers with systems up to 10 kilowatts (kW) in capacity.

238

Smart Metering Pilot Program Inc SMPPI | Open Energy Information  

Open Energy Info (EERE)

Metering Pilot Program Inc SMPPI Metering Pilot Program Inc SMPPI Jump to: navigation, search Name Smart Metering Pilot Program, Inc. (SMPPI) Place Washington, DC Product SMPPI is a non-profit corporation composed of representatives of Pepco, the D.C. Public Service Commission, the D.C. Office of People's Counsel, the D.C. Consumer Utility Board, and the International Brotherhood of Electrical Workers Local 1900. References Smart Metering Pilot Program, Inc. (SMPPI)[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Smart Metering Pilot Program, Inc. (SMPPI) is a company located in Washington, DC . References ↑ "Smart Metering Pilot Program, Inc. (SMPPI)" Retrieved from "http://en.openei.org/w/index.php?title=Smart_Metering_Pilot_Program_Inc_SMPPI&oldid=351192"

239

Smart Meters Offer 'Instant Gratification;' Help Houston Homeowners  

Broader source: Energy.gov (indexed) [DOE]

Meters Offer 'Instant Gratification;' Help Houston Meters Offer 'Instant Gratification;' Help Houston Homeowners Save Smart Meters Offer 'Instant Gratification;' Help Houston Homeowners Save July 1, 2011 - 12:15pm Addthis Houston resident Ruth Diorio explains to KPRC Local 2 News how much she's saved with her recently installed smart meter, which allows her to see her savings in real time. Houston resident Ruth Diorio explains to KPRC Local 2 News how much she's saved with her recently installed smart meter, which allows her to see her savings in real time. Liisa O'Neill Liisa O'Neill Former New Media Specialist, Office of Public Affairs What does this mean for me? Smart meters offer real time information on your energy use, which can help you lower your electricity bill. "Instant gratification" from a smart meter? So raves Houston homeowner Ruth

240

Scotia Energy Electricity - Net Metering Program (Nova Scotia, Canada) |  

Broader source: Energy.gov (indexed) [DOE]

Scotia Energy Electricity - Net Metering Program (Nova Scotia, Scotia Energy Electricity - Net Metering Program (Nova Scotia, Canada) Scotia Energy Electricity - Net Metering Program (Nova Scotia, Canada) < Back Eligibility Agricultural Commercial Industrial Low-Income Residential Multi-Family Residential Residential Schools Savings Category Water Buying & Making Electricity Home Weatherization Solar Wind Program Info State Nova Scotia Program Type Net Metering Provider Nova Scotia Power, Inc Nova Scotia Power Inc. Net Metering allows residential and commercial customers to connect small, renewable energy generating units to the provincial power grid. Generating units that produce renewable energy such as wind, solar, small hydro or biomass can be added to homes or businesses with the addition of a bi-directional meter. This meter monitors the electricity generated by the

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

SCE&G - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

SCE&G - Net Metering SCE&G - Net Metering SCE&G - Net Metering < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Tribal Government Savings Category Bioenergy Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State South Carolina Program Type Net Metering In August 2009, the South Carolina Public Service Commission issued an order mandating net metering be made available by the regulated electric utilities; the order incorporates a net metering settlement signed by the individual interveners, the Office of Regulatory Staff and the three investor-owned utilities (IOUs). The order detailed the terms of net metering, including ownership of RECs, in South Carolina and standardized

242

E-Print Network 3.0 - automatic survey meter Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

management services such as fine grained pricing schemes, automatic meter reading, demand response... to demand measurement and billing. Meters supporting automatic meter reading...

243

E-Print Network 3.0 - automatic meter reading Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

fine grained pricing schemes, automatic meter reading, demand response... to demand measurement and billing. Meters supporting automatic meter reading (AMR) can report demand......

244

Information and Instructions for Your Office Hours  

E-Print Network [OSTI]

Aug 7, 2014 ... INFORMATION on OFFICE HOURS and INSTRUCTIONS for TAOH. Please view rather than print this information. Current dates can be found...

Dominic Naughton

2014-08-07T23:59:59.000Z

245

High Performance Computing Data Center Metering Protocol  

Broader source: Energy.gov (indexed) [DOE]

High Performance High Performance Computing Data Center Metering Protocol Prepared for: U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Federal Energy Management Program Prepared by: Thomas Wenning Michael MacDonald Oak Ridge National Laboratory September 2010 ii Introduction Data centers in general are continually using more compact and energy intensive central processing units, but the total number and size of data centers continues to increase to meet progressive computing requirements. In addition, efforts are underway to consolidate smaller data centers across the country. This consolidation is resulting in a growth of high-performance computing facilities (i.e. - supercomputers) which consume large amounts of energy to support the numerically intensive

246

Secretary Chu's Message about Forrestal Electric Metering  

Broader source: Energy.gov (indexed) [DOE]

0 0 Dear Colleagues, The Department of Energy has a responsibility and an opportunity to lead by example in promoting sustainable energy practices. As many of you have heard me say, energy efficiency is one of our best and most immediate opportunities to save energy, cut utility bills and decrease carbon pollution. I want to thank you for the steps many of you have already taken to reduce energy consumption. Today, I'm asking all employees at the Forrestal Building to take these efforts to the next level by participating in a competition to save money by saving energy. We recently divided the Forrestal complex into five zones and installed electric meters to measure the daily electricity consumption of overhead lights and power outlets in each zone. You've probably seen

247

ARRA Program Celebrates Milestone 600,000 Smart Meter Installations |  

Broader source: Energy.gov (indexed) [DOE]

ARRA Program Celebrates Milestone 600,000 Smart Meter Installations ARRA Program Celebrates Milestone 600,000 Smart Meter Installations ARRA Program Celebrates Milestone 600,000 Smart Meter Installations April 17, 2012 - 3:09pm Addthis On April 11, 2012, DOE Recovery Act funding recipient Sacramento Municipal Utility District (SMUD) celebrated a major milestone in the development of a regional smart grid in California: the installation of over 600,000 smart meters. For the event, Congresswoman Doris Matsui (D-Sacramento) visited SMUD's customer service center and praised the program for implementing a system "that will be more efficient, more reliable, and better for consumers." SMUD's meter installations are nearly complete, with only a few thousand remaining. In addition to smart meters, SMUD's grid modernization efforts will include automated distribution systems, a

248

City of New Orleans - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

City of New Orleans - Net Metering City of New Orleans - Net Metering City of New Orleans - Net Metering < Back Eligibility Agricultural Commercial Residential Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Wind Solar Home Weatherization Program Info State Louisiana Program Type Net Metering Provider City Council Utilities Regulatory Office In May 2007, the New Orleans City Council adopted net-metering rules that are similar to rules adopted by the Louisiana Public Service Commission (PSC) in November 2005. The City Council's rules require Entergy New Orleans, an investor-owned utility regulated by the city, to offer net metering to customers with systems that generate electricity using solar energy, wind energy, hydropower, geothermal or biomass resources. Fuel

249

The Need for Essential Consumer Protections: Smart metering proposals and  

Broader source: Energy.gov (indexed) [DOE]

metering metering proposals and the move to time-based pricing. August 2010 The Need for Essential Consumer Protections: Smart metering proposals and the move to time-based pricing. August 2010 There is widespread consensus that the U.S. distribution and transmission systems for vital electricity service need to be modernized and upgraded. This modernization has been recently promoted under the rubric of the Smart Grid. The Smart Grid vision has three primary parts: (1) new communication and digital sensors and automation capabilities for the distribution and transmission systems; (2) new digital metering systems for all customers; and (3) direct interfaces between the new metering systems and customers through inhome technologies. The Need for Essential Consumer Protections: Smart metering proposals and

250

SaskPower Net Metering (Saskatchewan, Canada) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

SaskPower Net Metering (Saskatchewan, Canada) SaskPower Net Metering (Saskatchewan, Canada) SaskPower Net Metering (Saskatchewan, Canada) < Back Eligibility Commercial Agricultural Industrial Residential Savings Category Solar Buying & Making Electricity Program Info Funding Source SaskPower State Saskatchewan Program Type Net Metering Provider SaskPower Residents, farms and businesses with approved Environmental Preferred Technologies of up to 100 kilowatts (kW) of nominal (nameplate) generating capacity can deliver their excess electricity to our electrical grid. SaskPower will pay a one-time rebate, equivalent to 20% of eligible costs to a maximum payment of $20,000, for an approved and grid interconnected net metering project. The Net Metering Rebate is available to SaskPower, Saskatoon Light and Power and City of Swift Current electricity customers

251

U.S. Virgin Islands - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

U.S. Virgin Islands - Net Metering U.S. Virgin Islands - Net Metering U.S. Virgin Islands - Net Metering < Back Eligibility Commercial Fed. Government Institutional Local Government Residential Schools State Government Tribal Government Savings Category Solar Buying & Making Electricity Wind Program Info Program Type Net Metering In February 2007, the U.S. Virgin Islands Public Services Commission approved a limited net-metering program for residential and commercial photovoltaic (PV), wind-energy or other renewable energy system up to 10 kilowatts (kW) in capacity. In July 2009, the legislature passed Act 7075 that raised the capacity limits to 20 kW for residential systems, 100 kW for commercial systems, and 500 kW for public (which includes government, schools, hospitals). The aggregate capacity limit of all net-metered systems is five megawatts

252

City of Brenham - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

City of Brenham - Net Metering City of Brenham - Net Metering City of Brenham - Net Metering < Back Eligibility Agricultural Commercial General Public/Consumer Industrial Institutional Nonprofit Residential Schools State Government Savings Category Bioenergy Wind Buying & Making Electricity Energy Sources Solar Program Info State Texas Program Type Net Metering Provider City of Brenham In September 2010, the City of Brenham passed an ordinance adopting net metering and interconnection procedures. Customer generators up to 10 megawatts (MW) are eligible to participate, although customer generators with systems 20 kilowatts (kW) or less are eligible for a separate rider and expedited interconnection. The utility will install and maintain a meter capable of measuring flow of electricity in both directions. Any net

253

Utility-Scale Smart Meter Deployments, Plans & Proposals  

Broader source: Energy.gov (indexed) [DOE]

edisonfoundation.net/IEE edisonfoundation.net/IEE Utility-Scale Smart Meter Deployments, Plans & Proposals April 2010 Utility State Target Number of Meters Notes Resources AEP 1 IN, KY, MI, OH, OK, TX, VA, WV 5,000,000 AEP plans on deploying smart meters to all customers within their service territory and have deployed 10,000 meters to customers in South Bend, IN, and are presently deploying another 700,000 to AEP-Texas customers. Timing for the remaining deployments will depend on specific conditions in each of the seven operating company subsidiaries. AEP Corporate Sustainability Report 2009 2 Allegheny Power MD, PA, WV 700,000 Allegheny launched pilots in Morgantown, WV and Urbana, MD to test smart meters and thermostats (1,140 meters installed). In PA, Act 129 (2008)

254

Test procedures help ensure accuracy of orifice meters  

SciTech Connect (OSTI)

Orifice meter measurement with a chart recorder has been a standard in the petroleum industry for years. The meter consists of the plate/tube and recorder, requires minimal maintenance and can accurately measure a wide range of flow rates. It must be routinely tested to ensure sustained accuracy. The orifice meter measures differential pressure, static pressure, and temperature. However, the accuracy of the measurement is only as good as the calibration devices used in the test. A typical meter test consists of meter calibration, orifice plate inspection, quality of gas tests, and documentation (test report) to verify the data. The paper describes 19 steps that a gas technician can follow to conduct a thorough meter test.

Fillman, C.R. [Coastal Flow Measurement, Inc., Houston, TX (United States)

1996-07-01T23:59:59.000Z

255

2,363 METERS BOUYANT 7/8" POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,363 METERS BOUYANT 7/8" POLYOLEFIN MOORING LINE 10 METER LENGTH NYLON STIFFENER APPLIED TO TOP OF 1" NYLON EYE INTO EYE SPLICE 20 METERS 1 1/8" NYLON 697.4 METERS 7/16" WIRE ROPE 35 METERS 40 METERS 700 METERS 3/4" SAS, Wrench tighten. ** 3/4" SAS WITH BUSHING, Wrench tighten. ** .5 METER 1/2" CHAIN

256

Basic DC Meter Design ECE 2100 Circuit Analysis Laboratory  

E-Print Network [OSTI]

Basic DC Meter Design ECE 2100 Circuit Analysis Laboratory updated 8 January 2008 Pre-Laboratory Assignment 1. Design an ammeter with full scale current IFS equal to 5 mA using a meter movement rated at 0.5 mA and 100 mV. 2. Design a voltmeter with a full scale voltage VFS equal to 10 V using the meter

Miller, Damon A.

257

Proper Oil Sampling Intervals and Sample Collection Techniques Gasoline/Diesel/Natural Gas Engines  

E-Print Network [OSTI]

Proper Oil Sampling Intervals and Sample Collection Techniques Gasoline/Diesel/Natural Gas Engines: · Oil samples can be collected during oil changes. Follow manufacturers recommendations on frequency (hours, mileage, etc) of oil changes. · Capture a sample from the draining oil while the oil is still hot

258

Metering Best Practices: A Guide to Achieving Utility Resource...  

Broader source: Energy.gov (indexed) [DOE]

Policy Act of 2005. mbpg.pdf More Documents & Publications Operations & Maintenance Best Practices Guide: Chapter 8 Guidance for Electric Metering in Federal Buildings...

259

BELANGER, T. V., AND M. T. MONTGOMERY. Seepage meter errors  

Science Journals Connector (OSTI)

tor is applied, field test point estimates of seep- ..... Location, depth, and mean seepage rate for each meter in a transect across Indian River lagoon near.

2000-03-19T23:59:59.000Z

260

Maritime Electric- Net Metering (Prince Edward Island, Canada)  

Broader source: Energy.gov [DOE]

In December 2005 The Renewable Energy Act and associated Regulations came into effect. A Government policy objective incorporated in the Act was the introduction of net metering for...

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

A spectral light absorption meter for measurements in the sea  

Science Journals Connector (OSTI)

Dec 17, 1974 ... the measuring period, that the horizontal di- ... ance in the upper few meters at high solar ... area of the spherical collector and the ratio.

2000-01-04T23:59:59.000Z

262

Stick-on Electricity Meter - Energy Innovation Portal  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Building Energy Efficiency Find More Like This Return to Search Stick-on Electricity Meter Lawrence Berkeley National Laboratory Contact LBL About This Technology Publications:...

263

Wavelength meter having single mode fiber optics multiplexed inputs  

DOE Patents [OSTI]

A wavelength meter having a single mode fiber optics input is disclosed. The single mode fiber enables a plurality of laser beams to be multiplexed to form a multiplexed input to the wavelength meter. The wavelength meter can provide a determination of the wavelength of any one or all of the plurality of laser beams by suitable processing. Another aspect of the present invention is that one of the laser beams could be a known reference laser having a predetermined wavelength. Hence, the improved wavelength meter can provide an on-line calibration capability with the reference laser input as one of the plurality of laser beams.

Hackel, R.P.; Paris, R.D.; Feldman, M.

1993-02-23T23:59:59.000Z

264

Nevada Renewable Energy Application For Net Metering Customers...  

Open Energy Info (EERE)

Renewable Energy Application For Net Metering Customers Jump to: navigation, search OpenEI Reference LibraryAdd to library Form: Nevada Renewable Energy Application For Net...

265

The Intersection of Net Metering and Retail Choice: An Overview...  

Office of Environmental Management (EM)

five different theoretical models describing different ways competitive suppliers and utilities provide net metering options for their customers. They then provided case studies to...

266

The Need for Essential Consumer Protections: Smart metering proposals...  

Broader source: Energy.gov (indexed) [DOE]

Grid vision has three primary parts: (1) new communication and digital sensors and automation capabilities for the distribution and transmission systems; (2) new digital metering...

267

Wavelength meter having single mode fiber optics multiplexed inputs  

DOE Patents [OSTI]

A wavelength meter having a single mode fiber optics input is disclosed. The single mode fiber enables a plurality of laser beams to be multiplexed to form a multiplexed input to the wavelength meter. The wavelength meter can provide a determination of the wavelength of any one or all of the plurality of laser beams by suitable processing. Another aspect of the present invention is that one of the laser beams could be a known reference laser having a predetermined wavelength. Hence, the improved wavelength meter can provide an on-line calibration capability with the reference laser input as one of the plurality of laser beams.

Hackel, Richard P. (Livermore, CA); Paris, Robert D. (San Ramon, CA); Feldman, Mark (Pleasanton, CA)

1993-01-01T23:59:59.000Z

268

2,349 METERS BOUYANT 7/8" POLYOLEFIN MOORING LINE  

E-Print Network [OSTI]

2,349 METERS BOUYANT 7/8" POLYOLEFIN MOORING LINE 10 METER LENGTH NYLON STIFFENER APPLIED TO 1" NYLON EYE INTO EYE SPLICE 697.4 METERS 7/16" WIRE ROPE 40 METERS 700 METERS 3/4" SAS, Wrench tighten. ** 3/4" SAS WITH BUSHING, Wrench tighten. ** .5 METER 1/2" CHAIN 5 TON SWIVEL INDUCTIVE CABLE BREAKOUT

269

Bradbury Science Museum announces winter opening hours  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Bradbury Science Museum winter hours Bradbury Science Museum winter hours Bradbury Science Museum announces winter opening hours Museum will be closed on Christmas Day (December 25) and New Year's Day (January 1, 2011). December 21, 2010 Bradbury Science Museum Bradbury Science Museum Contact Communications Office (505) 667-7000 Often called "a window to the Laboratory," the museum annually attracts thousands of visitors from all over the world. LOS ALAMOS, New Mexico, December 21, 2010-Los Alamos National Laboratory's Bradbury Science Museum will be closed on Christmas Day (December 25) and New Year's Day (January 1, 2011). On all other days, the museum will observe regular opening hours: from 10 a.m. to 5 p.m. Tuesdays to Saturdays, and from 1 to 5 p.m. Sundays and Mondays. Often called "a window to the Laboratory," the museum annually attracts

270

MARKETING DEPARTMENT Office Hours Fall 2014  

E-Print Network [OSTI]

MARKETING DEPARTMENT Office Hours Fall 2014 NAME OFFICE HOURS COURSE # COURSE TITLE DAY TIME ROOM MKTG 470.2 MKTG 496.1 Marketing Research Marketing & Sales Analytics MW MW 1000-1150 1400-1550 SSW 3620-1400 and by appointment MKTG 498.1-3 MKTG 779.1 MKTG 790.1 MKTG 797.1 MKTG 798.1-3 Investigation & Report Ad. Marketing

Gallo, Linda C.

271

About equivalent interval colorings of weighted graphs  

Science Journals Connector (OSTI)

Given a graph G=(V,E) with strictly positive integer weights @w"i on the vertices i@?V, a k-interval coloring of G is a function I that assigns an interval I(i)@?{1,...,k} of @w"i consecutive integers (called colors) to each vertex i@?V. If two adjacent ... Keywords: Equivalent colorings, Interval coloring problem, Weighted graphs

Mathieu Bouchard; Mirjana angalovi?; Alain Hertz

2009-10-01T23:59:59.000Z

272

Spectral Statistics of RR Intervals in ECG  

E-Print Network [OSTI]

The statistical properties (fluctuations) of heartbeat intervals (RR intervals) in ECG are studied and compared with the predictions of Random Matrix Theory (RMT). It is found that heartbeat intervals only locally exhibit the fluctuation patterns (universality) predicted by the RMT. This finding shows that heartbeat dynamics is of the mixed type where regular and irregular (chaotic) regimes coexist and the Berry-Robnik theory can be applied. It is also observed that the distribution of heartbeat intervals is well described by the one-parameter Brody distribution. The parameter $\\beta $ of the Brody distribution is seen to be connected with the dynamical state of the heart.

Martinis, M; Knezevic, A; Crnugelj, J

2003-01-01T23:59:59.000Z

273

Recent developments in orifice meter and flow conditioner research  

SciTech Connect (OSTI)

In 1969 concerns were raised regarding the validity of the orifice meter`s coefficient of discharge uncertainty. An effort to resolve these concerns resulted in an internationally supported research project which produced a new sharp-edged concentric orifice meter empirical database and coefficient of discharge equation. However, the new empirical database and coefficient of discharge equation did not account for all of the differences being encountered in orifice metering. And in 1986, as a derivative of the coefficient of discharge equation research, questions were raised regarding the influences of installation effects on the orifice meter`s coefficient of discharge. The 1986 EC research data indicated that the flow conditioner and straight pipe installation requirements of the flow measurement standards were inadequate to prevent biasing of the orifice meter`s coefficient of discharge by flow disturbances generated from upstream piping elements. Data generated from 1990 through 1993 by GRI sponsored SWRI and NIST research confirmed the original EC biasing and further identified differential pressure tap radial position sensitivity and velocity profile and swirl angle theory deficiencies. Current research is continuing to define installation effects influences and identify possible solutions.

LaNasa, P.J. [CPL and Associates, Houston, TX (United States)

1995-12-31T23:59:59.000Z

274

Multiphase pumps and flow meters avoid platform construction  

SciTech Connect (OSTI)

One of the newest wrinkles in efficiency in BP`s Eastern Trough Area Project (ETAP) is the system for moving multiphase oil, water and gas fluids from the Machar satellite field to the Marnock Central Processing Facility (CPF). Using water-turbine-driven multiphase pumps and multiphase flow meters, the system moves fluid with no need for a production platform. In addition, BP has designed the installation so it reduces and controls water coning, thereby increasing recoverable reserves. Both subsea multiphase booster stations (SMUBS) and meters grew out of extensive development work and experience at Framo Engineering AS (Framo) in multiphase meters and multiphase pump systems for subsea installation. Multiphase meter development began in 1990 and the first subsea multiphase meters were installed in the East Spar Project in Australia in 1996. By September 1998, the meters had been operating successfully for more than 1 year. A single multiphase meter installed in Marathon`s West Brae Project has also successfully operated for more than 1 year. Subsea meters for ETAP were installed and began operating in July 1998.

Elde, J.

1999-02-01T23:59:59.000Z

275

Energy Secretary Chu Announces Five Million Smart Meters Installed  

Broader source: Energy.gov (indexed) [DOE]

Announces Five Million Smart Meters Installed Announces Five Million Smart Meters Installed Nationwide as Part of Grid Modernization Effort Energy Secretary Chu Announces Five Million Smart Meters Installed Nationwide as Part of Grid Modernization Effort June 13, 2011 - 12:00am Addthis Washington, DC - At a White House Grid Modernization event today, U.S. Department of Energy Secretary Steven Chu announced that more than five million smart meters have been installed nationwide as part of Recovery Act-funded efforts to accelerate modernization of the Nation's electric grid. Smart meters will provide utility companies with greater information about how much electricity is being used throughout their service areas. They will also give consumers access to real-time information about their energy consumption, allowing them to make well-informed decisions about how

276

Grays Harbor PUD - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Net Metering Net Metering Grays Harbor PUD - Net Metering < Back Eligibility Commercial Industrial Residential Savings Category Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Solar Home Weatherization Wind Program Info State District of Columbia Program Type Net Metering Provider Grays Harbor PUD Grays Harbor PUD's net-metering program differs slightly from what is required by Washington state law in that Grays Harbor PUD reimburses customers for net excess generation (NEG), at the end of each year, at 50% of the utility's retail rate. State law allows utilities to require customers to surrender NEG to the utility, without reimbursement, at the end of a 12-month billing cycle. Grays Harbor PUD has voluntarily gone

277

Improvements in Shallow (Two-Meter) Temperature Measurements and Data  

Open Energy Info (EERE)

Improvements in Shallow (Two-Meter) Temperature Measurements and Data Improvements in Shallow (Two-Meter) Temperature Measurements and Data Interpretation Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Improvements in Shallow (Two-Meter) Temperature Measurements and Data Interpretation Abstract The Great Basin Center for Geothermal Energy has been working on improvements in shallow (two-meter) temperature surveys in two areas: overcoming limitations posed by difficult ground conditions with the use of a portable rock drill, and improvements in temperature measurements and interpretations Previous 2-meter temperature surveys conducted by the Great Basin Center for Geothermal Energy have been limited to areas that were not excessively rocky. This limitation has been overcome by the use of a

278

Secretary Chu Announces Two Million Smart Grid Meters Installed Nationwide  

Broader source: Energy.gov (indexed) [DOE]

Two Million Smart Grid Meters Installed Two Million Smart Grid Meters Installed Nationwide Secretary Chu Announces Two Million Smart Grid Meters Installed Nationwide August 31, 2010 - 12:00am Addthis Columbus, OH - At an event today at Battelle headquarters in Columbus, Ohio, U.S. Energy Secretary Steven Chu announced that two million smart grid meters have been installed across the country, helping to reduce energy costs for families and businesses. As a result of funding from the Recovery Act, smart grid technology is speeding the modernization of the nation's electrical grid, helping to reduce the amount of time needed to respond to energy disruptions and enable consumers to monitor their energy consumption and costs. So far, more than 180,000 smart meters have been installed in Ohio. "As a result of an unprecedented investment from the Recovery Act, smart

279

Smart Meters on Tap for Owasso, Oklahoma | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Meters on Tap for Owasso, Oklahoma Meters on Tap for Owasso, Oklahoma Smart Meters on Tap for Owasso, Oklahoma September 10, 2010 - 12:52pm Addthis Stephen Graff Former Writer & editor for Energy Empowers, EERE What does this mean for me? Recovery Act-funded smart meter pilot project will help residents lower utility bills. Smart meter installations help utility company respond quicker to power outages. Seeing real-time energy use could help cities save 10% of their annual energy consumption. Owasso, Oklahoma, known as the "city with no limits," is living up to its name with sustainability and energy. The evidence is everywhere. You can't visit the city's website -- or Facebook, Twitter and Flickr accounts, for that matter -- without noticing its robust recycling and composting program, water conversation focus or

280

Colorado Wind Resource at 50 Meters Above Ground Level  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Wind Resource at 50 Meters Above Ground Level Wind Resource at 50 Meters Above Ground Level Metadata also available as Metadata: Identification_Information Data_Quality_Information Spatial_Data_Organization_Information Spatial_Reference_Information Entity_and_Attribute_Information Distribution_Information Metadata_Reference_Information Identification_Information: Citation: Citation_Information: Originator: AWS TrueWind/NREL Publication_Date: December 2003 Title: Colorado Wind Resource at 50 Meters Above Ground Level Geospatial_Data_Presentation_Form: vector digital data Online_Linkage: Description: Abstract: Annual average wind resource potential for the state of Colorado,

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Chevron facility focused on commercial orifice-meter research  

SciTech Connect (OSTI)

Research to determine the accuracy of commercial orifice meters for custody-transfer measurement has indicated that high-volume gas meters can be flow-proven while in such service. The research further yielded more accurate orifice-meter discharge coefficient equations (at Reynolds numbers greater than 4,000,000) than current equations of the International Standards Organization (ISO) and the American Petroleum Institute (API). These are partial findings of a major study conducted by Chevron Oil Field Research Co. at its Venice, La., calibration facility.

Jones, E.H.; Ferguson, K.R.

1987-07-27T23:59:59.000Z

282

Parity meter for charge qubits: an efficient quantum entangler  

E-Print Network [OSTI]

We propose a realization of a charge parity meter based on two double quantum dots alongside a quantum point contact. Such a device is a specific example of the general class of mesoscopic quadratic quantum measurement detectors previously investigated by Mao et al. [Phys. Rev. Lett. 93, 056803 (2004)]. Our setup accomplishes entangled state preparation by a current measurement alone, and allows the qubits to be effectively decoupled by pinching off the parity meter. Two applications of the parity meter are discussed: the measurement of Bell's inequality in charge qubits and the realization of a controlled NOT gate.

B. Trauzettel; A. N. Jordan; C. W. J. Beenakker; M. Buttiker

2006-04-26T23:59:59.000Z

283

hourly solar radiation | OpenEI  

Open Energy Info (EERE)

solar radiation solar radiation Dataset Summary Description (Abstract): A need for predicting hourly global radiation exists for many locations particularly in Bangladesh for which measured values are not available and daily values have to be estimated from sunshine data. The CPRG model has been used to predict values of hourly Gh for Dhaka (23.770N, 90.380E), Chittagong (22.270N, 91.820E) and Bogra (24.850N, 89.370E) for = ±7.50, ±22.50, ±37.50, ±52.50, ±67.50, ±82.50 and ±97.50 i.e., for ±1/2, ±3/2, ±5/2, ±7/2, ±9/2, ±11/2, ±13/2 hours before and after solar noon and the computed values for Source Renewable Energy Research Centre Date Released October 22nd, 2003 (11 years ago) Date Updated Unknown Keywords Bangladesh documentation hourly solar radiation SWERA

284

Ethics and Public Health 3 credit hours  

E-Print Network [OSTI]

PUB H Ethics and Public Health 3 credit hours Summer, 2009 Instructor: Ann Cook, PhD, MPA, Research U.S. public health policies. The course begins with a rationale for studying the ethical dimensions of public health and then examines ethical decisonmaking in arenas such as policy development, research

Vonessen, Nikolaus

285

Credit Based; Beginning Swimming Credit/Hour  

E-Print Network [OSTI]

the pool. To be able to swim at least 50 yards with one of the learned strokes. Required Materials: Swim. Make-Ups: Only two make-ups allowed by swimming laps during open swim/lap swim at MSU pool. Lap swimCredit Based; Beginning Swimming Credit/Hour s Class Title Lead Instructo r Phone Email Office

Maxwell, Bruce D.

286

Project Management Foundation 21 hours, $895  

E-Print Network [OSTI]

Project Management Foundation 21 hours, $895 The fundamental project management processes. In group exercises, participants gain an understanding of how the project management processes are used during each phase of a project to build a better, more effective project plan. Topics Include

Alabama in Huntsville, University of

287

2009-2010 Advertising Curriculum Hours PREREQUISITES  

E-Print Network [OSTI]

2009-2010 Advertising Curriculum Hours PREREQUISITES First Year English 101, 102 6 or satisfactory placement test score Second Year Advertising 250 3 ___ Public Relations 270 3 ___ 3 History 241 ___ Statistics 201 3 ___ Math 125 or Math 141 Accounting 200 3 ___ Advertising 310 3 ___ Advertising 250 TOTAL 31

Grissino-Mayer, Henri D.

288

2007-2008 Advertising Curriculum Hours PREREQUISITES  

E-Print Network [OSTI]

2007-2008 Advertising Curriculum Hours PREREQUISITES First Year English 101, 102 6-4 ___ Math 119 or 123 or satisfactory placement test score TOTAL 32-33 Second Year Advertising 250 3 ___ Advertising 310 3 ___ Adv 250 and admission to the major TOTAL 31 Third Year Psychology 110 3 ___ Business

Grissino-Mayer, Henri D.

289

2011-12 Advertising Curriculum Hours PREREQUISITES  

E-Print Network [OSTI]

2011-12 Advertising Curriculum Hours PREREQUISITES First Year English 101, 102 6-33 Math 141: Math 130 or placement level Second Year Advertising 250 3 ___ Public Relations 270 3 ___ 3 Economics 201 4 ___ Statistics 201 3 ___ Math 125 or Math 141 Accounting 200 3 ___ Advertising 310 3

Grissino-Mayer, Henri D.

290

2010-11 Advertising Curriculum Hours PREREQUISITES  

E-Print Network [OSTI]

2010-11 Advertising Curriculum Hours PREREQUISITES First Year English 101, 102 6-33 Math 141: Math 130 or placement level Second Year Advertising 250 3 ___ Public Relations 270 3 ___ 3 Economics 201 4 ___ Statistics 201 3 ___ Math 125 or Math 141 Accounting 200 3 ___ Advertising 310 3

Grissino-Mayer, Henri D.

291

2012-13 Advertising Curriculum Hours PREREQUISITES  

E-Print Network [OSTI]

2012-13 Advertising Curriculum Hours PREREQUISITES First Year English 101*, 102* 6 Advertising 250 3 ___ Public Relations 270 3 ___ 3 History 241*, 242* or 261*, 262* 6 ___ ___ 4 English or Math 141 Accounting 200 3 ___ Advertising 310 3 ___ Advertising 250 TOTAL 31 Third Year Psychology 110

Grissino-Mayer, Henri D.

292

The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California  

SciTech Connect (OSTI)

Net metering has become a widespread mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), but has faced challenges as PV installations grow to a larger share of generation in a number of states. This paper examines the value of the bill savings that customers receive under net metering, and the associated role of retail rate design, based on a sample of approximately two hundred residential customers of California's two largest electric utilities. We find that the bill savings per kWh of PV electricity generated varies by more than a factor of four across the customers in the sample, which is largely attributable to the inclining block structure of the utilities' residential retail rates. We also compare the bill savings under net metering to that received under three potential alternative compensation mechanisms, based on California's Market Price Referent (MPR). We find that net metering provides significantly greater bill savings than a full MPR-based feed-in tariff, but only modestly greater savings than alternative mechanisms under which hourly or monthly net excess generation is compensated at the MPR rate.

Energy and Resources Group, University of California, Berkeley; Darghouth, Naim R.; Barbose, Galen; Wiser, Ryan

2011-06-01T23:59:59.000Z

293

NERSC Edison Phase I Hours Used Report  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Edison Phase I Hours Used Edison Phase I Hours Used Edison Phase I Hours Used Edison Usage Chart Edison Usage Chart Date Hours Used (in millions) Percent of Maximum Possible (24 hours/day) 06/23/2013 0.226 88.6 06/22/2013 0.239 93.9 06/21/2013 0.248 97.1 06/20/2013 0.240 94.0 06/19/2013 0.233 91.3 06/18/2013 0.245 96.0 06/17/2013 0.251 98.4 06/16/2013 0.243 95.3 06/15/2013 0.245 95.9 06/14/2013 0.246 96.5 06/13/2013 0.240 94.1 06/12/2013 0.128 50.4 06/11/2013 0.215 84.5 06/10/2013 0.225 88.4 06/09/2013 0.228 89.6 06/08/2013 0.225 88.3 06/07/2013 0.121 47.5 06/06/2013 0.223 87.4 06/05/2013 0.250 98.0 06/04/2013 0.234 91.6 06/03/2013 0.218 85.5 06/02/2013 0.246 96.4 06/01/2013 0.230 90.0 05/31/2013 0.215 84.5 05/30/2013 0.212 83.1 05/29/2013 0.223 87.3 05/28/2013 0.237 93.0 05/27/2013 0.226 88.5 05/26/2013 0.229 89.9

294

Health Promotion Graduate Student Coordinator 15-20 hours/week $18/hour (pending approval)  

E-Print Network [OSTI]

Health Promotion Graduate Student Coordinator 15-20 hours/week $18/hour (pending approval year. The Graduate Student Coordinator for Health Promotion is responsible for assisting the Fitness & Health Promotion Coordinator in the development, promotion, management and implementation of Campus Rec

Lafferriere, Gerardo

295

Society, Technology and the Environment-3credit hours Spanish for Engineering-6 credit hours  

E-Print Network [OSTI]

Society, Technology and the Environment- 3credit hours Spanish for Engineering- 6 credit hours 21st May to 22nd June 2012 The University of Alabama College of Engineering in collaboration with Pamplona for any student interested in technology and the environment; students will have the opportunity to study

Simaan, Nabil

296

The influence of frequency of milking and nursing upon twenty four hour milk production of Hereford cows  

E-Print Network [OSTI]

and atght medium producing Holeteiae ta early or late lectsttoa. The cows werc hand~mtlhad for one and oae-half dsye at two-hour intervals aad were tn)ected with 10 X. U. of oaytocia bofors they ware milked. Rha hLgh producing cows ehouad a marked...

Chow, Guillermo

1964-01-01T23:59:59.000Z

297

Sub-Hour Solar Data for Power System Modeling From Static Spatial Variability Analysis: Preprint  

SciTech Connect (OSTI)

High penetration renewable integration studies need high quality solar power data with spatial-temporal correlations that are representative of a real system. This paper will summarize the research relating sequential point-source sub-hour global horizontal irradiance (GHI) values to static, spatially distributed GHI values. This research led to the development of an algorithm for generating coherent sub-hour datasets that span distances ranging from 10 km to 4,000 km. The algorithm, in brief, generates synthetic GHI values at an interval of one-minute, for a specific location, using SUNY/Clean Power Research, satellite-derived, hourly irradiance values for the nearest grid cell to that location and grid cells within 40 km.

Hummon, M.; Ibanez, E.; Brinkman, G.; Lew, D.

2012-12-01T23:59:59.000Z

298

Nano-to-Meter-Scale Building, a Summary  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Nano-to-Meter-Scale Building, a Summary Nano-to-Meter-Scale Building, a Summary Speaker(s): Danijel Rebolj Date: December 18, 2009 - 12:00pm Location: 90-3122 Development of the core nanotechnologies and synthetic biology is leading to results that are extremely interesting for production of the buildings on the nano level, thus growing buildings on site from the nano into the meter range. Although areas like nanorobotics, programmable materials, and programmable cells are still considered to be speculative to some extent, their fast development encouraged us to start systematic research of new ways for modeling and construction of buildings using bio-nano-technologies. The main motivation, however, was the recognition that, if designed in a sustainable way, the new ways of nano-to-meter-scale

299

City of Danville - Net Metering | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Danville - Net Metering Danville - Net Metering City of Danville - Net Metering < Back Eligibility Commercial Residential Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Water Solar Program Info State Virginia Program Type Net Metering For a renewable fuel generator with a capacity of 25 kilowatts (kW) or less, a notification form shall be submitted at least 30 days prior to the date the customer intends to interconnect their renewable fuel generator to the Utility's facilities. Renewable fuel generators with capacity over 25 kW are required to submit forms no later than 60 days prior to planned interconnection. The Utility will review and determine whether the requirements for Interconnection have been met. More information on this

300

Smart Meters Helping Oklahoma Consumers Save Hundreds During Summer Heat |  

Broader source: Energy.gov (indexed) [DOE]

Smart Meters Helping Oklahoma Consumers Save Hundreds During Summer Smart Meters Helping Oklahoma Consumers Save Hundreds During Summer Heat Smart Meters Helping Oklahoma Consumers Save Hundreds During Summer Heat July 26, 2011 - 4:27pm Addthis Small business owner Steve Kaplan told ABC News’ “Show Me the Money” on Good Morning America that he's saving over $320 per month compared to last summer, which they calculated could result in $1,300 a year. Small business owner Steve Kaplan told ABC News' "Show Me the Money" on Good Morning America that he's saving over $320 per month compared to last summer, which they calculated could result in $1,300 a year. Liisa O'Neill Liisa O'Neill Former New Media Specialist, Office of Public Affairs What does this mean for me? Utility-provided meters give consumers real-time information on how

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Two Million Smart Meters and Counting | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Million Smart Meters and Counting Million Smart Meters and Counting Two Million Smart Meters and Counting August 31, 2010 - 6:02pm Addthis Elizabeth Meckes Elizabeth Meckes Director of User Experience & Digital Technologies, Office of Public Affairs What does this mean for me? Smart meter technology will help families and businesses cut their energy costs by reducing response time for energy disruptions and enabling consumers to better monitor their consumption. The implementation of smart grid technologies could reduce electricity use by more than four percent annually by 2030 -- that would mean consumers around the country would see savings of over $20 billion each year. Secretary Steven Chu visited Battelle headquarters in Columbus, Ohio, today to make a big announcement about our nation's electrical grid: an

302

Category:Smart Grid Projects - Advanced Metering Infrastructure | Open  

Open Energy Info (EERE)

Metering Infrastructure Metering Infrastructure Jump to: navigation, search Smart Grid Projects - Advanced Metering Infrastructure category Pages in category "Smart Grid Projects - Advanced Metering Infrastructure" The following 31 pages are in this category, out of 31 total. A ALLETE Inc., d/b/a Minnesota Power Smart Grid Project B Baltimore Gas and Electric Company Smart Grid Project Black Hills Power, Inc. Smart Grid Project Black Hills/Colorado Electric Utility Co. Smart Grid Project C CenterPoint Energy Smart Grid Project Central Maine Power Company Smart Grid Project Cheyenne Light, Fuel and Power Company Smart Grid Project City of Fulton, Missouri Smart Grid Project City of Glendale Water and Power Smart Grid Project City of Quincy, FL Smart Grid Project City of Westerville, OH Smart Grid Project

303

A continuous reading fluorescence meter for eddy diffusion studies  

E-Print Network [OSTI]

LIBRARY A AIS COLLEGE OF TEXAS A CONTINUOUS READINO FLUORESCENCE METER FOR EDDY DIFFUSION STUDIES BY Frank Wooten Moon, Jr. A Thesis Submitted to ths Qraduate Scbool of the Agricultural and Mechanical College oi' Texas in partial...

Moon, Frank Wooten

1956-01-01T23:59:59.000Z

304

Value creation and value capture of advanced electricity meter information  

E-Print Network [OSTI]

Advanced or smart metering has been a hot topic in the electricity community for several years. Despite the excitement about the technology, few business cases are actually able to justify the investment cost. One reason ...

Oesterlin, Ulf

2011-01-01T23:59:59.000Z

305

Radiofrequency fields associated with the Itron smart meter  

Science Journals Connector (OSTI)

......density enhancement factor of (1.6)2 or 2.56 for use in Equation (A1). REFERENCES 1 FERC. Assessment of Demand Response and Advanced Metering. (2008) Federal Energy Regulatory Commission. 2 FCC. Evaluating Compliance with FCC Guidelines......

R. A. Tell; G. G. Sias; A. Vazquez; J. Sahl; J. P. Turman; R. I. Kavet; G. Mezei

2012-08-01T23:59:59.000Z

306

25 years ago: the official farewell to the meter  

E-Print Network [OSTI]

On october 21st 1983 took place in S\\`evres on the western outskirts of Paris the official funeral of the meter. With it the notion of distance as a physical observable was buried.

Thomas Schucker

2008-10-20T23:59:59.000Z

307

LM to Meet Energy Metering Goals Through Enhanced Data Collection...  

Broader source: Energy.gov (indexed) [DOE]

usage and metering. The first goal states that LM should reduce energy use intensity (EUI) by 30 percent by fiscal year (FY) 2020, as compared to the FY 2003 baseline. The...

308

Metering and Calibration in LoanSTAR Buildings  

E-Print Network [OSTI]

or many stories away from each other. Power measurements across multiple panels can increase costs dramatically. Buildings often have multiple electrical feeds or feed additional buildings. Asbestos is found in many chilled and hot water piping... installed before 1970. Installation of thermal metering requires asbestos abatement. The cost to remove the asbestos may be too high to justify the thermal metering. (6) Timely installation of equipment requires an intensive coordination effort during...

O'Neal, D. L.; Bryant, J. A.; Turner, W. D.; Glass, M. G.

1990-01-01T23:59:59.000Z

309

Frequency domain design of interval controller  

E-Print Network [OSTI]

significant role in the analysis and design of interval systems. Its external properties are also discussed. The image set approach & frequency domain criteria can be used to calculate the IP stability margin. The frequency domain criteria are used...

Park, Wunyong

1993-01-01T23:59:59.000Z

310

The One-Way Speed of Light on Rotating Earth and the Definition of the Meter  

E-Print Network [OSTI]

Since 1983 the meter is defined to be the "length of the path travelled by light in vacuum during a time interval of 1/299792458 of a second". If there was exactly one single consistent method of synchronizing clocks, or if all corresponding methods were equivalent, one could infer from the validity of special relativity theory on a definite value of the one-way speed of light c in inertial frames. It is true that sufficiently slowly separated clocks always show middle in time reflection when sending and receiving light signals. But a simple consideration proves that the one-way speed of light is not a constant in rotating systems, in principle detectable with only one clock. On basis of a new internal synchronization method, this also affects all local inertial frames on rotating Earth, too, violating an absolute constancy of the one-way speed of light. This is not a contradiction to Einstein's original theory of relativity but to the present definition of the meter. Based on the constant local average value c of light going there and back, however, a modification for the definition of the meter is suggested, which would not depend on synchronization of any distant clocks. Appendix: FitzGerald-Lorentz contraction and time dilation, according to Einstein's generally accepted understanding, should be purely kinematic effects and would not need any dynamic explanation. But an analysis of Ehrenfest's paradox of the rotating disk shows that it is not possible to separate exactly relativistic kinematics from dynamics. The necessity of such a fundamental restriction is well known for a long time - though only from quantum mechanics till now.

Peter Ostermann

2002-08-19T23:59:59.000Z

311

Extremal properties of interval control systems  

E-Print Network [OSTI]

EXTREMAL PROPERTIES OF INTERVAL CONTROL SYSTEMS A Thesis by FARIS RAGHEB KAMAL Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE May 1991 Major... Subject: Electrical Engineering EXTREMAL PROPERTIES OF INTERVAL CONTROL SYSTEMS A Thesis by FARIS RAGHEB I&AMAL Approved as to style and content b1 Mohammed A. Dahleh (Chair of Committee) ostas Georghiades (Member ) Ehsani Mehrdad (Member...

Kamal, Faris Ragheb

2012-06-07T23:59:59.000Z

312

Faculty Office Hours Fall 2014 Aberle, James  

E-Print Network [OSTI]

Faculty Office Hours Fall 2014 Aberle, James GWC 326 01:30 PM 02:45 PMM T W F to Tuesday is through:30 AMR to Coleman, James BYENG 450 08:45 AM 09:45 AMT R to By Appointment Cotter, Jeff GWC 424 03:15 PM:00 AM 09:30 AMF to Or at a time arranged via e-mail to reisslein@asu.edu Rodriguez, Armando GWC 352 10

Zhang, Yanchao

313

Modeling demand response and economic impact of advanced and smart metering  

Science Journals Connector (OSTI)

Advanced metering constitutes an essential component of communications between electricity suppliers and consumers. It may be possible to augment demand response by coupling Advanced Metering Infrastructure (AMI)...

Praneeth Aketi; Suvrajeet Sen

2014-09-01T23:59:59.000Z

314

Building a wireless mesh networked real-time electricity metering system in an MIT dormitory .  

E-Print Network [OSTI]

??A competitive, closed-loop information feedback system of wireless electricity meters was designed, tested, and implemented in seven MIT dormitory rooms. The meters utilized Allegro Hall (more)

Oehlerking, Austin L

2009-01-01T23:59:59.000Z

315

Hour-by-Hour Cost Modeling of Optimized Central Wind-Based Water Electrolysis Production  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Hour-by-Hour Cost Hour-by-Hour Cost Modeling of Optimized Central Wind-Based Water Electrolysis Production Genevieve Saur (PI), Chris Ainscough (Presenter), Kevin Harrison, Todd Ramsden National Renewable Energy Laboratory January 17 th , 2013 This presentation does not contain any proprietary, confidential, or otherwise restricted information 2 Acknowledgements * This work was made possible by support from the U.S. Department of Energy's Fuel Cell Technologies Office within the Office of Energy Efficiency and Renewable Energy (EERE). http://www.eere.energy.gov/topics/hydrogen_fuel_cells.html * NREL would like to thank our DOE Technology Development Managers for this project, Sara Dillich, Eric Miller, Erika Sutherland, and David Peterson. * NREL would also like to acknowledge the indirect

316

Smart Meters and a Smarter Grid | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Smart Meters and a Smarter Grid Smart Meters and a Smarter Grid Smart Meters and a Smarter Grid May 16, 2011 - 4:40pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory Have you heard of smart meters? Do you understand them? If so, you've had a leg up on me until now. I've heard of smart meters here and there from the odd news article or website, but to me the grapevine has been more like an invisible beehive: all buzz and no honey. Where are they? Why don't I have one yet, and will I have to buy it to be part of the system? Do they really save energy? Is Big Brother counting my kilowatts for me now, or what? These are the questions that don't keep me up at night, but I suspect more and more people are asking. Photo credit: U.S. Department of Energy We talked about what a Smart Grid is in February. The standard electrical

317

Compensated count-rate circuit for radiation survey meter  

DOE Patents [OSTI]

A count-rate compensating circuit is provided which may be used in a portable Geiger-Mueller (G-M) survey meter to ideally compensate for counting loss errors in the G-M tube detector. In a G-M survey meter, wherein the pulse rate from the G-M tube is converted into a pulse rate current applied to a current meter calibrated to indicate dose rate, the compensated circuit generates and controls a reference voltage in response to the rate of pulses from the detector. This reference voltage is gated to the current-generating circuit at a rate identical to the rate of pulses coming from the detector so that the current flowing through the meter is varied in accordance with both the frequency and amplitude of the reference voltage pulses applied thereto so that the count rate is compensated ideally to indicate a true count rate within 1% up to a 50% duty cycle for the detector. A positive feedback circuit is used to control the reference voltage so that the meter output tracks true count rate indicative of the radiation dose rate.

Todd, Richard A. (Powell, TN)

1981-01-01T23:59:59.000Z

318

Compensated count-rate circuit for radiation survey meter  

DOE Patents [OSTI]

A count-rate compensating circuit is provided which may be used in a portable Geiger-Mueller (G-M) survey meter to ideally compensate for couting loss errors in the G-M tube detector. In a G-M survey meter, wherein the pulse rate from the G-M tube is converted into a pulse rate current applied to a current meter calibrated to indicate dose rate, the compensation circuit generates and controls a reference voltage in response to the rate of pulses from the detector. This reference voltage is gated to the current-generating circuit at a rate identical to the rate of pulses coming from the detector so that the current flowing through the meter is varied in accordance with both the frequency and amplitude of the reference voltage pulses applied thereto so that the count rate is compensated ideally to indicate a true count rate within 1% up to a 50% duty cycle for the detector. A positive feedback circuit is used to control the reference voltage so that the meter output tracks true count rate indicative of the radiation dose rate.

Todd, R.A.

1980-05-12T23:59:59.000Z

319

20140430_Green Machine Florida Canyon Hourly Data  

SciTech Connect (OSTI)

Employing innovative product developments to demonstrate financial and technical viability of producing electricity from low temperature geothermal fluids, coproduced in a mining operation, by employing ElectraTherm's modular and mobile heat-to-power "micro geothermal" power plant with output capacity expected in the 30-70kWe range. The Green Machine is an Organic Rankine Cycle power plant. The Florida Canyon machine is powered by geothermal brine with air cooled condensing. The data provided is an hourly summary from 01 April to 30 April 2014.

Thibedeau, Joe

2014-05-05T23:59:59.000Z

320

Green Machine Florida Canyon Hourly Data 20130731  

SciTech Connect (OSTI)

Employing innovative product developments to demonstrate financial and technical viability of producing electricity from low temperature geothermal fluids, coproduced in a mining operation, by employing ElectraTherm's modular and mobile heat-to-power "micro geothermal" power plant with output capacity expected in the 30-70kWe range. The Green Machine is an Organic Rankine Cycle power plant. The Florida Canyon machine is powered by geothermal brine with air cooled condensing. The data provided is an hourly summary from 7/1/13 to 7/31/13.

Vanderhoff, Alex

2013-08-30T23:59:59.000Z

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

20130416_Green Machine Florida Canyon Hourly Data  

SciTech Connect (OSTI)

Employing innovative product developments to demonstrate financial and technical viability of producing electricity from low temperature geothermal fluids, coproduced in a mining operation, by employing ElectraTherm's modular and mobile heat-to-power "micro geothermal" power plant with output capacity expected in the 30-70kWe range. The Green Machine is an Organic Rankine Cycle power plant. The Florida Canyon machine is powered by geothermal brine with air cooled condensing. The data provided is an hourly summary from 4/16/13.

Vanderhoff, Alex

2013-04-24T23:59:59.000Z

322

Green Machine Florida Canyon Hourly Data  

SciTech Connect (OSTI)

Employing innovative product developments to demonstrate financial and technical viability of producing electricity from low temperature geothermal fluids, coproduced in a mining operation, by employing ElectraTherm's modular and mobile heat-to-power "micro geothermal" power plant with output capacity expected in the 30-70kWe range. The Green Machine is an Organic Rankine Cycle power plant. The Florida Canyon machine is powered by geothermal brine with air cooled condensing. The data provided is an hourly summary from 6/1/13 to 6/30/13

Vanderhoff, Alex

2013-07-15T23:59:59.000Z

323

Green Machine Florida Canyon Hourly Data  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Employing innovative product developments to demonstrate financial and technical viability of producing electricity from low temperature geothermal fluids, coproduced in a mining operation, by employing ElectraTherm's modular and mobile heat-to-power "micro geothermal" power plant with output capacity expected in the 30-70kWe range. The Green Machine is an Organic Rankine Cycle power plant. The Florida Canyon machine is powered by geothermal brine with air cooled condensing. The data provided is an hourly summary from 6/1/13 to 6/30/13

Vanderhoff, Alex

324

20130416_Green Machine Florida Canyon Hourly Data  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Employing innovative product developments to demonstrate financial and technical viability of producing electricity from low temperature geothermal fluids, coproduced in a mining operation, by employing ElectraTherm's modular and mobile heat-to-power "micro geothermal" power plant with output capacity expected in the 30-70kWe range. The Green Machine is an Organic Rankine Cycle power plant. The Florida Canyon machine is powered by geothermal brine with air cooled condensing. The data provided is an hourly summary from 4/16/13.

Vanderhoff, Alex

325

20140430_Green Machine Florida Canyon Hourly Data  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Employing innovative product developments to demonstrate financial and technical viability of producing electricity from low temperature geothermal fluids, coproduced in a mining operation, by employing ElectraTherm's modular and mobile heat-to-power "micro geothermal" power plant with output capacity expected in the 30-70kWe range. The Green Machine is an Organic Rankine Cycle power plant. The Florida Canyon machine is powered by geothermal brine with air cooled condensing. The data provided is an hourly summary from 01 April to 30 April 2014.

Thibedeau, Joe

326

Green Machine Florida Canyon Hourly Data 20130731  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Employing innovative product developments to demonstrate financial and technical viability of producing electricity from low temperature geothermal fluids, coproduced in a mining operation, by employing ElectraTherm's modular and mobile heat-to-power "micro geothermal" power plant with output capacity expected in the 30-70kWe range. The Green Machine is an Organic Rankine Cycle power plant. The Florida Canyon machine is powered by geothermal brine with air cooled condensing. The data provided is an hourly summary from 7/1/13 to 7/31/13.

Vanderhoff, Alex

327

Interval Data Systems Inc | Open Energy Information  

Open Energy Info (EERE)

Interval Data Systems Inc Interval Data Systems Inc Jump to: navigation, search Name Interval Data Systems Inc Address 135 Beaver Street Place Waltham, Massachusetts Zip 02452 Sector Efficiency Product Efficiency and monitoring solutions for buildings Website http://www.intdatsys.com/ Coordinates 42.384614°, -71.207508° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.384614,"lon":-71.207508,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

328

Cleanroom After-Hours Policy Original: 11/04  

E-Print Network [OSTI]

Cleanroom After-Hours Policy Original: 11/04 Revised: 2//05 CAMD strives to maintain and improve laboratory and User safety along with User efficiency. After- Hours work inside the cleanroom (CR + all hours of LSU Staff holidays. After-Hours Access Request · Cleanroom-trained Users can apply for CR

329

Guidelines for Use MIT Libraries' 24 Hour Study Space  

E-Print Network [OSTI]

Guidelines for Use MIT Libraries' 24 Hour Study Space Access to and use of the MIT Libraries' 24://libguides.mit.edu/hours)). The following principles guide access to 24-hour spaces for all users of the MIT Libraries: Expectations Library policies Behavior Library users in the 24-hour study spaces are expected to refrain from: � Behaviors

330

Smart Meter Investments Support Rural Economy in Arkansas  

Broader source: Energy.gov (indexed) [DOE]

Smart Meter Investments Support Rural Economy in Arkansas Smart Meter Investments Support Rural Economy in Arkansas Woodruff Electric Cooperative (Woodruff) serves customers in seven eastern Arkansas counties. The proportion of residents living in poverty in those counties is more than double the national average. As a member-owned rural electric cooperative, Woodruff is connected to its customers and engaged in economic development efforts to bring more jobs and higher incomes to local communities. In order to bring the capital investment and its accompanying economic benefits to the region without delay, Woodruff completed its project installation ahead of schedule. With a total budget of $5 million, funded partially with nearly $2.4 million in Recovery Act funding from the U.S. Department of Energy (DOE), Woodruff was able to install 14,450 smart meters and supporting

331

Smarter Meters Help Customers Budget Electric Service Costs  

Broader source: Energy.gov (indexed) [DOE]

Tri-State Smart Grid Investment Grant Tri-State Smart Grid Investment Grant 1 Tri-State's service area includes parts of Fannin County, Georgia; Polk County, Tennessee; and Cherokee County, North Carolina. Smarter Meters Help Customers Budget Electric Service Costs Tri-State Electric Membership Cooperative (Tri-State) is a distribution rural electric cooperative that primarily serves more than 12,000 rural customers, many of whom have low-incomes living at or near poverty level across a multi-state region (see map). Under their smart grid project, Tri-State has replaced conventional electromechanical meters with solid-state smart meters and implemented advanced electricity service programs in order to give customers greater control over their energy use and costs.

332

The Need for Essential Consumer Protections: Smart Metering Proposals and  

Broader source: Energy.gov (indexed) [DOE]

Metering Metering Proposals and the Move to Time-Based Pricing The Need for Essential Consumer Protections: Smart Metering Proposals and the Move to Time-Based Pricing There is a widespread consensus that the U.S. distribution and transmission systems for vital electricity service need to be modernized and upgraded to handle not only load growth, but the integration of renewable resources and the potential for a significant increase in electric-powered vehicles. This modernization has been recently promoted under the rubric of the Smart Grid. The Smart Grid vision has three primary parts: (1) new communication and digital sensors and automation capabilities for the distribution and transmission systems, designed to make the grid more reliable and capable of integrating renewable and local-level distribution

333

Cyprus Smart metering demo (Smart Grid Project) | Open Energy Information  

Open Energy Info (EERE)

Cyprus Smart metering demo (Smart Grid Project) Cyprus Smart metering demo (Smart Grid Project) Jump to: navigation, search Project Name Cyprus Smart metering demo Country Cyprus Coordinates 35.126411°, 33.429859° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":35.126411,"lon":33.429859,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

334

Working With Your Utility to Obtain Metering Services  

Broader source: Energy.gov (indexed) [DOE]

Dykes Dykes Federal Segment Mgr Georgia Power/Southern Company Wednesday, 22 May 2013 Federal Utility Partnership Working Group Spring 2013 - May 22-23 San Francisco, CA Hosted by: Pacific Gas and Electric Company  What is the Government Requirement ◦ New DoD Directive  What is Available from Your Serving Utility  Customer Metering Services  Issues to Consider  Conclusion 4.4 million customers 42,000+ MW 27,000 miles of transmission lines 3,700 substations 26,000 employees Other subsidiaries: Southern Linc, Southern Power, Southern Telecom, Southern Nuclear Retail Service Territory across 120,000 square miles  Section 103, EPAct 2005 - All Federal Agencies ◦ Meter electricity on all facilities 30,000 SqFt and larger ◦ Meter those facilities with significant energy usage

335

Microsoft Word - CLPUD Revenue Metering CX.doc  

Broader source: Energy.gov (indexed) [DOE]

Gregory Vassallo Gregory Vassallo TPC-ALVEY Proposed Action: New Revenue Meters at Central Lincoln's Florence and Berrydale Substations Budget Information: Work Order # 00004866, Task 04 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.6 Additions or modifications to electric power transmission facilities that would not affect the environment beyond the previously developed facility... Location: Lane County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA plans to upgrade revenue metering at Central Lincoln People's Utility District's (Central Lincoln) Florence and Berrydale Substations to 115-kV. Bonneville will retire the 12.5-kV revenue metering at Central Lincoln's Florence, Berrydale, and Heceta Beach Substations once

336

Entropy Meters and the Entropy of Non-extensive Systems  

E-Print Network [OSTI]

In our derivation of the second law of thermodynamics from the relation of adiabatic accessibility of equilibrium states we stressed the importance of being able to scale a system's size without changing its intrinsic properties. This leaves open the question of defining the entropy of macroscopic, but unscalable systems, such as gravitating bodies or systems where surface effects are important. We show here how the problem can be overcome, in principle, with the aid of an `entropy meter'. An entropy meter can also be used to determine entropy functions for non-equilibrium states and mesoscopic systems.

Elliott H. Lieb; Jakob Yngvason

2014-03-30T23:59:59.000Z

337

Accurate 100:1 Rangeability Linear Response Head Meter  

E-Print Network [OSTI]

as regards its sensitivity to changes in density, ie; a change of 1% in density results in a metering error of 1/2%. The compensation equation is: mass flow Qm volumetric f 10\\'/Qv Additionally, factors such as vapor expansion and thermal expansion... as regards its sensitivity to changes in density, ie; a change of 1% in density results in a metering error of 1/2%. The compensation equation is: mass flow Qm volumetric f 10\\'/Qv Additionally, factors such as vapor expansion and thermal expansion...

Grant, G. H.

338

Commercial Buildings Partnership Projects - Metered Data Format and Delivery  

SciTech Connect (OSTI)

A number of the Commercial Building Partnership Projects (CBPs) will require metering, monitoring, data analysis and verification of savings after the retrofits are complete. Although monitoring and verification (M&V) agents are free to use any metering and monitoring devices that they chose, the data they collect should be reported to Pacific Northwest National Laboratory (PNNL) in a standard format. PNNL will store the data collected in its CBP database for further use by PNNL and U.S. Department of Energy. This document describes the data storage process and the deliver format of the data from the M&V agents.

Katipamula, Srinivas

2010-11-16T23:59:59.000Z

339

US Recovery Act Smart Grid Projects - Advanced Metering Infrastructure |  

Open Energy Info (EERE)

Projects - Advanced Metering Infrastructure Projects - Advanced Metering Infrastructure Jump to: navigation, search CSV Loading map... {"format":"googlemaps3","type":"ROADMAP","types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"limit":500,"offset":0,"link":"all","sort":[""],"order":[],"headers":"show","mainlabel":"","intro":"","outro":"","searchlabel":"\u2026 further results","default":"","geoservice":"google","zoom":false,"width":"600px","height":"350px","centre":false,"layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","icon":"","visitedicon":"","forceshow":true,"showtitle":true,"hidenamespace":false,"template":false,"title":"","label":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"locations":[{"text":"

340

Microwave Pickup on the Crawford Hill 7-meter Jeff McMahon  

E-Print Network [OSTI]

Microwave Pickup on the Crawford Hill 7-meter Telescope Jeff McMahon Project Advisor: Suzanne-Meter Telescope The Crawford Hill 7-meter telescope located at Bell labs in Holmdel, New Jersey is being considered for use in the CapMAP project. This antenna is a 7-meter offset Cassegrain reflector antenna

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

EVALUATING EFFECTIVENESS OF RAMP Evidence from the twin cities ramp meter shut-off  

E-Print Network [OSTI]

Chapter 9 EVALUATING EFFECTIVENESS OF RAMP METERS Evidence from the twin cities ramp meter shut-625-6354 Abstract: Ramp meters in the Twin Cities have been turned off for eight weeks in Fall 2000 in an experiment representative freeways during the afternoon peak period. Several performance measures for ramp metering

Levinson, David M.

342

Active fault creep variations at Chihshang, Taiwan, revealed by creep meter monitoring, 19982001  

E-Print Network [OSTI]

Active fault creep variations at Chihshang, Taiwan, revealed by creep meter monitoring, 1998] The daily creep meter data recorded at Chihshang in 1998­2001 are presented. The Chihshang creep meter similar annual shortening rates: 16.2 mm at the Tapo site (comprising two connected creep meters) and 15

Lee, Jian-Cheng

343

How to Read Residential Electric and Natural Gas Meters | Department of  

Broader source: Energy.gov (indexed) [DOE]

Residential Electric and Natural Gas Meters Residential Electric and Natural Gas Meters How to Read Residential Electric and Natural Gas Meters June 24, 2012 - 3:00pm Addthis An electromechanical electric meter on the side of a house. | Photo courtesy of ©iStockphoto/epantha An electromechanical electric meter on the side of a house. | Photo courtesy of ©iStockphoto/epantha A digital electric meter on the side of a house. | Photo courtesy of ©iStockphoto/nbehmans A digital electric meter on the side of a house. | Photo courtesy of ©iStockphoto/nbehmans A natural gas meter on a house. | Photo courtesy of ©iStockphoto/fstockfoto A natural gas meter on a house. | Photo courtesy of ©iStockphoto/fstockfoto An electromechanical electric meter on the side of a house. | Photo courtesy of ©iStockphoto/epantha

344

hourly emission factors | OpenEI  

Open Energy Info (EERE)

60 60 Varnish cache server Browse Upload data GDR 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142278660 Varnish cache server hourly emission factors Dataset Summary Description Emissions from energy use in buildings are usually estimated on an annual basis using annual average multipliers. Using annual numbers provides a reasonable estimation of emissions, but it provides no indication of the temporal nature of the emissions. Therefore, there is no way of understanding the impact on emissions from load shifting and peak shaving technologies such as thermal energy storage, on-site renewable energy, and demand control. Source NREL Date Released April 11th, 2011 (3 years ago) Date Updated April 11th, 2011 (3 years ago)

345

Estimation of hourly global and diffuse solar radiation from hourly sunshine duration  

SciTech Connect (OSTI)

A statistical procedure has been employed to develop correlations of monthly-mean-hourly global and diffuse solar radiation on a horizontal surface to hourly sunshine duration. Several years of measured data on solar radiation and sunshine duration, reported in the literature for two stations in the southern African region, is employed for this purpose. The applicability of the developed correlations is tested by estimating solar radiation for a new location. The excellent agreement between the measured and estimated data for that station the wide applicability of the method.

Gopinathan, K.K (National Univ. of Lesotho, Roma (South Africa))

1992-01-01T23:59:59.000Z

346

P\\procedure\\EU#7 Page 1 of 2 TITLE: PROCEDURE FOR RECORDING AND TRANSMITTING METER READINGS  

E-Print Network [OSTI]

P\\procedure\\EU#7 Page 1 of 2 TITLE: PROCEDURE FOR RECORDING AND TRANSMITTING METER READINGS FOR NEW METER SETS, METER REPLACEMENTS AND WHEN THE ACCOUNTABILITY FOR THE METERS USAGE CHANGES OBJECTIVE AND PURPOSE: To provide a timely and accurate method of capturing meter readings when a meter is changed out

Fernandez, Eduardo

347

1. From the Mail Services website, (www.princeton.edu/mail) click on Metered Mail to access the Meter Request Form.  

E-Print Network [OSTI]

1. From the Mail Services website, (www.princeton.edu/mail) click on Metered Mail to access the Meter Request Form. 2. Log in using your Princeton NetID and password. The system will pre the drop-down menu. To enter a new chartstring, click "Create New." Online Meter Request Form A step

Singh, Jaswinder Pal

348

Advanced computational simulation of flow phenomena associated with orifice meters  

SciTech Connect (OSTI)

This paper presents and discusses results from a series of computational fluid dynamics (CFD) simulations of fluid flow phenomena associated with orifice meters. These simulations were performed using a new, state-of-the-art CFD code developed at Southwest Research Institute. This code is based on new techniques designed to take advantage of parallel computers to increase computational performance and fidelity of simulation results. This algorithm uses a domain decomposition strategy to create grid systems for very complex geometries composed of simpler geometric subregions, allowing for the accurate representation of the fluid flow domain. The domain decomposition technique maps naturally to parallel computer architectures. Here, the concept of message-passing is used to create a parallel algorithm, using the Parallel Virtual Machine (PVM) library. This code is then used to simulate the flow through an orifice meter run consisting of an orifice with a beta ratio of 0.5 and air flowing at a Reynolds number of 91,100. The work discussed in this paper is but the first step in developing a Virtual Metering Research Facility to support research, analysis, and formulation of new standards for metering.

Freitas, C.J. [Southwest Research Inst., San Antonio, TX (United States)

1995-12-31T23:59:59.000Z

349

Advanced accelerator simulation research: miniaturizing accelerators from kilometers to meters  

E-Print Network [OSTI]

Advanced accelerator simulation research: miniaturizing accelerators from kilometers to meters W: Advanced accelerator research is aimed at finding new technologies that can dramatically reduce the size and cost of future high-energy accelerators. Supercomputing is already playing a dramatic and critical role

Geddes, Cameron Guy Robinson

350

Multi-vendor Penetration Testing in the Advanced Metering Infrastructure  

E-Print Network [OSTI]

Infrastructure (AMI) is changing the way electric energy is produced, priced, and consumed. The introduction,mcdaniel}@cse.psu.edu Abstract - The advanced metering infrastructure (AMI) is revolutionizing electrical grids. Intelligent AMI we develop an archetypal attack tree approach to guide penetration testing across multiple

McDaniel, Patrick Drew

351

The Statewide Benefits Of Net-Metering In California  

E-Print Network [OSTI]

on the costs and benefits of NEM to the Governor and Legislature. 4 Id. 5 California Solar Future: Growing to the total, "bundled" energy rate, which includes not only the cost of generation, but transmission of 2013 3 See Net Energy Metering Cost-Effectiveness Evaluation, Energy and Environmental Economics, Inc

Kammen, Daniel M.

352

Secure and robust multipath routings for advanced metering infrastructure  

Science Journals Connector (OSTI)

A Smart Grid is the modernization of the electricity grid using communication technology with the prime goals of reducing energy consumption as well as cost increasing reliability and creating new services for all participants. It comprises key components ... Keywords: Advanced Metering Infrastructure, Last-mile access, Multipath routing protocols, Security, Smart grid, Wireless mesh network

Binod Vaidya; Dimitrios Makrakis; Hussein Mouftah

2013-11-01T23:59:59.000Z

353

ParkingMeter: Balancing Energy Savings and Service Availability  

E-Print Network [OSTI]

ParkingMeter: Balancing Energy Savings and Service Availability Riccardo Crepaldi University of Illinois at Urbana Champaign rcrepal2@illinois.edu Ryan Welsh University of Illinois at Urbana Champaign rjwelsh2@illinois.edu Robin H. Kravets University of Illinois at Urbana Champaign rhk@illinois

Kravets, Robin

354

Hydrostatic bearings for a turbine fluid flow metering device  

DOE Patents [OSTI]

A rotor assembly fluid metering device has been improved by development of a hydrostatic bearing fluid system which provides bearing fluid at a common pressure to rotor assembly bearing surfaces. The bearing fluid distribution system produces a uniform film of fluid between bearing surfaces and allows rapid replacement of bearing fluid between bearing surfaces, thereby minimizing bearing wear and corrosion. 3 figs.

Fincke, J.R.

1982-05-04T23:59:59.000Z

355

Personal energy metering Simon Hay, Andrew Rice and Andy Hopper  

E-Print Network [OSTI]

based on energy and usage data collected over the course of a year. We also studied the addi- tionalPersonal energy metering Simon Hay, Andrew Rice and Andy Hopper {sjeh3,acr31,ah12}@cam.ac.uk Computer Laboratory, University of Cambridge 1 Introduction Every day each of us consumes a significant

Cambridge, University of

356

Commercial building end-use energy metering inventory  

SciTech Connect (OSTI)

Pacific Northwest Laboratory conducted a comprehensive inventory of end-use metered data. The inventory did not discover many sources of metered end-use data; however, research into existing data bases and extensive discussions with professionals associated with building energy conservation have enabled a clear characterization to be developed of the types of metered data that are required to further energy conservation in commercial buildings. Based on the results of the inventory and this clarification of data requirements, the adequacy of existing data bases has been assessed, and recommendations have been developed for future federal data collection efforts. A summary of sources of existing metered end-use data is provided in Section 2.1 and its adequacy has been summarized. Collection of further end-use metered data is both desirable and valuable for many areas of building energy conservation research. Empirical data are needed to address many issues which to date have been addressed using only simulation techniques. The adequacy of using simulation techniques for various purposes needs to be assessed through comparison with measured data. While these data are expensive to acquire, it is cost-effective to do so in the long run, and the need is not being served by the private market. The preceding conclusion based on results from the inventory of existing data highlights two important facts: First, although the data are widely desired in the private sector, they are not widely available. Second, where suitable data are publicly available and contain the desired supporting information, their collection has generally been funded by government-sponsored research.

Heidell, J.A.; Mazzucchi, R.P.; Reilly, R.W.

1985-03-01T23:59:59.000Z

357

"YEAR","MONTH","STATE","UTILITY CODE","UTILITY NAME","RESIDENTIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","TOTAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","COMMERCIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","INDUSTRIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","TRANSPORTATION PHOTOVOLTAIC NET METERING CUSTOMER COUNT","TOTAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","RESIDENTIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION WIND ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL WIND INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL WIND INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL WIND INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION WIND INSTALLED NET METERING CAPACITY (MW)","TOTAL WIND INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL WIND NET METERING CUSTOMER COUNT","COMMERCIAL WIND NET METERING CUSTOMER COUNT","INDUSTRIAL WIND NET METERING CUSTOMER COUNT","TRANSPORTATION WIND NET METERING CUSTOMER COUNT","TOTAL WIND NET METERING CUSTOMER COUNT","RESIDENTIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL OTHER INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL OTHER INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL OTHER INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION OTHER INSTALLED NET METERING CAPACITY (MW)","TOTAL OTHER INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL OTHER NET METERING CUSTOMER COUNT","COMMERCIAL OTHER NET METERING CUSTOMER COUNT","INDUSTRIAL OTHER NET METERING CUSTOMER COUNT","TRANSPORTATION OTHER NET METERING CUSTOMER COUNT","TOTAL OTHER NET METERING CUSTOMER COUNT","RESIDENTIAL TOTAL ENERGY SOLD BACK TO THE UTILITY (MWh)","COMMERCIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION TOTAL INSTALLED NET METERING CAPACITY (MW)","TOTAL INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL TOTAL NET METERING CUSTOMER COUNT","COMMERCIAL TOTAL NET METERING CUSTOMER COUNT","INDUSTRIAL TOTAL NET METERING CUSTOMER COUNT","TRANSPORTATION TOTAL NET METERING CUSTOMER COUNT","TOTAL NET METERING CUSTOMER COUNT","RESIDENTIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","COMMERCIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","INDUSTRIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TRANSPORTATION ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TOTAL ELECTRIC ENERGY SOLD BACK TO THE UTILITYFOR ALL STATES SERVED(MWh)","RESIDENTIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","COMMERCIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INDUSTRIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","TRANSPORTATION INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","RESIDENTIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","COMMERCIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","INDUSTRIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","TRANSPORTATION NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","NET METERING CUSTOMER COUNT FOR ALL STATES SERVED"  

U.S. Energy Information Administration (EIA) Indexed Site

UTILITYFOR ALL STATES SERVED(MWh)","RESIDENTIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","COMMERCIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INDUSTRIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","TRANSPORTATION INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","RESIDENTIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","COMMERCIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","INDUSTRIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","TRANSPORTATION NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","NET METERING CUSTOMER COUNT FOR ALL STATES SERVED"

358

"YEAR","MONTH","STATE","UTILITY CODE","UTILITY NAME","RESIDENTIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","TOTAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","COMMERCIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","INDUSTRIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","TRANSPORTATION PHOTOVOLTAIC NET METERING CUSTOMER COUNT","TOTAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","RESIDENTIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION WIND ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL WIND INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL WIND INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL WIND INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION WIND INSTALLED NET METERING CAPACITY (MW)","TOTAL WIND INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL WIND NET METERING CUSTOMER COUNT","COMMERCIAL WIND NET METERING CUSTOMER COUNT","INDUSTRIAL WIND NET METERING CUSTOMER COUNT","TRANSPORTATION WIND NET METERING CUSTOMER COUNT","TOTAL WIND NET METERING CUSTOMER COUNT","RESIDENTIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL OTHER INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL OTHER INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL OTHER INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION OTHER INSTALLED NET METERING CAPACITY (MW)","TOTAL OTHER INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL OTHER NET METERING CUSTOMER COUNT","COMMERCIAL OTHER NET METERING CUSTOMER COUNT","INDUSTRIAL OTHER NET METERING CUSTOMER COUNT","TRANSPORTATION OTHER NET METERING CUSTOMER COUNT","TOTAL OTHER NET METERING CUSTOMER COUNT","RESIDENTIAL TOTAL ENERGY SOLD BACK TO THE UTILITY (MWh)","COMMERCIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION TOTAL INSTALLED NET METERING CAPACITY (MW)","TOTAL INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL TOTAL NET METERING CUSTOMER COUNT","COMMERCIAL TOTAL NET METERING CUSTOMER COUNT","INDUSTRIAL TOTAL NET METERING CUSTOMER COUNT","TRANSPORTATION TOTAL NET METERING CUSTOMER COUNT","TOTAL NET METERING CUSTOMER COUNT","RESIDENTIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","COMMERCIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","INDUSTRIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TRANSPORTATION ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TOTAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","RESIDENTIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","COMMERCIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INDUSTRIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","TRANSPORTATION INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","RESIDENTIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","COMMERCIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","INDUSTRIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","TRANSPORTATION NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","NET METERING CUSTOMER COUNT FOR ALL STATES SERVED"  

U.S. Energy Information Administration (EIA) Indexed Site

UTILITY FOR ALL STATES SERVED(MWh)","RESIDENTIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","COMMERCIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INDUSTRIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","TRANSPORTATION INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","RESIDENTIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","COMMERCIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","INDUSTRIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","TRANSPORTATION NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","NET METERING CUSTOMER COUNT FOR ALL STATES SERVED"

359

BNL | Center for Functional Nanomaterials Hours of Operation  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

CFN Hours of Operation CFN Hours of Operation Normal working hours at the CFN are 8 a.m. to 6 p.m. Working Outside of Normal Hours CFN scientific and technical personnel, as well as external users, may need to work outside of normal operating hours, during which time support is limited and many colleagues may not be around. Therefore, working outside the 8 a.m. to 6 p.m. envelope on weekdays, or anytime on weekends and holidays, requires special precautions, especially if working in a laboratory. CFN users are expected to work at the CFN during normal working hours. Users with extensive experience working at the CFN may be granted permission by the appropriate facility leader and ES&H Coordinator to work after hours. Users first must complete the Request to Work After-Hours at

360

ESB Smart Meter Projects (Smart Grid Project) | Open Energy Information  

Open Energy Info (EERE)

ESB Smart Meter Projects ESB Smart Meter Projects Country Ireland Headquarters Location Cork, Ireland Coordinates 51.897873°, -8.471087° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":51.897873,"lon":-8.471087,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Clustering of Meter-wave Luminous Objects toward Monoceros  

E-Print Network [OSTI]

A distribution of the meter-wave luminous objects, which are bright at frequency 74 MHz (a wavelength of 4 m) but not detectable at 1.4 GHz (21 cm) in the VLA surveys, shows a notable concentration in a scale of a few degrees toward Monoceros [(l, b)=(225, 4)]. We argue that it is a part of giant radio relics associated with a nearby cluster of galaxies with cz~2400$ km s^{-1} centered on the spiral galaxy NGC 2377. The angular separation of these objects from the clustering center is consistent with the separation of distant relics to the cluster center if scaled by distance. This fact implies that the concentrations of meter-wave luminous objects can be used as a tracer of the structure of the Local Supercluster and it's vicinity.

Shuji Deguchi; Kazutaka Koike

2008-11-19T23:59:59.000Z

362

Hydrostatic bearings for a turbine fluid flow metering device  

DOE Patents [OSTI]

A rotor assembly fluid metering device has been improved by development of a hydrostatic bearing fluid system which provides bearing fluid at a common pressure to rotor assembly bearing surfaces. The bearing fluid distribution system produces a uniform film of fluid distribution system produces a uniform film of fluid between bearing surfaces and allows rapid replacement of bearing fluid between bearing surfaces, thereby minimizing bearing wear and corrosion.

Fincke, J.R.

1980-05-02T23:59:59.000Z

363

EFFECTS OF AN ANTIDEPRESSANT DOSE OF KETAMINE ON PREFRONTAL ASPARTATE, GLUTAMINE AND GABA LEVELS IN HEALTHY SUBJECTS: ASSESSING THE POST-INFUSION INTERVAL WITH 1H-MRS  

E-Print Network [OSTI]

IN HEALTHY SUBJECTS: ASSESSING THE POST-INFUSION INTERVAL WITH 1H-MRS Milan Scheidegger1,2 , Alexander Fuchs1 at investigating the neurometabolic changes in the 3-4 hour post-infusion interval when the antidepressant effect by a continuous infusion of 0.25 mg/kg/h over 40 minutes. Single voxel 1 H MRS data were acquired from a volume

364

Microsoft Word - eMeter 10-11-01 Response to DOE RFI.doc  

Broader source: Energy.gov (indexed) [DOE]

Addressing Policy and Logistical Challenges to smart grid Implementation: Addressing Policy and Logistical Challenges to smart grid Implementation: Response to Department of Energy RFI November 1, 2010 eMeter Strategic Consulting Background eMeter is a smart grid software company that provides smart network application platform (SNAP) software to integrate smart meters and smart grid communications networks and devices with utility IT systems. eMeter also provides smart grid application software such as meter data management (MDM) and consumer engagement software. Being vendor-neutral toward all meter, hardware, and legacy utility software systems (e.g. CIS and Billing), eMeter has a unique, unbiased and global perspective on smart grid IT issues. In addition, eMeter's principals have participated in the definition and development of the

365

100 Meter Time of Flight System for Transmission Experiments Michael Rapp, Yaron Danon, Robert Block  

E-Print Network [OSTI]

100 Meter Time of Flight System for Transmission Experiments Michael Rapp, Yaron Danon, Robert of the detectors was chosen to take advantage of the neutron beam geometry at the detector location, 100 meters

Danon, Yaron

366

WINDExchange: Utility-Scale Land-Based 80-Meter Wind Maps  

Wind Powering America (EERE)

Programs & Data Utility-Scale Land-Based 80-Meter Wind Maps The U.S. Department of Energy provides an 80-meter (m) height, high-resolution wind resource map for the United...

367

Why Is the Speed of Light in Meters Per Second What It Is? |...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Invention > Stump the Scientist > Why Is the Speed of Light in Meters Per Second What It Is? Why Is the Speed of Light in Meters Per Second What It Is? 2012.08.27 Chief Scientist...

368

Effects of geometric scaling on static pressure measurements in orifice flow-meters  

E-Print Network [OSTI]

. (Mech) University of Mysore, India Chair of Advisory Committee: Dr. G. L. Morrison It is estimated that there are over one million orifice meters in operation today in the United States of America. . The accuracy of these meters.... It is estimated that there are over one million orifice meters in operation today in the United States of America. The accuracy of these meters is such that uncertainties of millions of dollars a year result from their use [1]. The basic idea employed...

Sarker, Arunava

2012-06-07T23:59:59.000Z

369

Video game console usage and national energy consumption: Results from a field-metering study  

E-Print Network [OSTI]

with their free energy audit program. Meters were installedinstalled as part of an energy audit program. Users may be

Desroches, Louis-Benoit

2013-01-01T23:59:59.000Z

370

1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. HIGH-ACCURACY LASER POWER AND ENERGY METER CALIBRATION SYSTEM . . . . . . . . 2  

E-Print Network [OSTI]

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. HIGH-ACCURACY LASER POWER AND ENERGY METER CALIBRATION SYSTEM . . . . . . . . 2 2.1 Calibration

371

Status of Net Metering: Assessing the Potential to Reach Program Caps (Poster)  

SciTech Connect (OSTI)

Several states are addressing the issue of net metering program caps, which limit the total amount of net metered generating capacity that can be installed in a state or utility service territory. In this analysis, we examine net metering caps to gain perspective on how long net metering will be available in various jurisdictions under current policies. We also surveyed state practices and experience to understand important policy design considerations.

Heeter, J.; Bird, L.; Gelman, R.

2014-10-01T23:59:59.000Z

372

Status of Net Metering: Assessing the Potential to Reach Program Caps  

SciTech Connect (OSTI)

Several states are addressing the issue of net metering program caps, which limit the total amount of net metered generating capacity that can be installed in a state or utility service territory. In this analysis, we examine net metering caps to gain perspective on how long net metering will be available in various jurisdictions under current policies. We also surveyed state practices and experience to understand important policy design considerations.

Heeter, J.; Gelman, R.; Bird, L.

2014-09-01T23:59:59.000Z

373

United States- Land Based and Offshore Annual Average Wind Speed at 100 Meters  

Broader source: Energy.gov [DOE]

Full-size, high resolution version of the 100-meter land-based and offshore wind speed resource map.

374

Meter as Mechanism: A Neural Network that Learns Metrical Michael Gasser, Douglas Eck and Robert Port  

E-Print Network [OSTI]

Meter as Mechanism: A Neural Network that Learns Metrical Patterns Michael Gasser, Douglas Eck that apparently underlies both music and some examples of speech production is meter. Yet detailed measurements of pulses that conform to particular meters. In addition, beginning with an initial state with no biases

Gasser, Michael

375

Feeling Music: Integration of Auditory and Tactile Inputs in Musical Meter Perception  

E-Print Network [OSTI]

Feeling Music: Integration of Auditory and Tactile Inputs in Musical Meter Perception Juan Huang1 are integrated in humans performing a musical meter recognition task. Subjects discriminated between two types coherent meter percepts, and 3) Simultaneously presented bimodal inputs where the two channels contained

Wang, Xiaoqin

376

Detecting Meter in Recorded Music Joseph E. Flannick, Rachel W. Hall, and Robert Kelly  

E-Print Network [OSTI]

Detecting Meter in Recorded Music Joseph E. Flannick, Rachel W. Hall, and Robert Kelly Dept) to identify the primary rhythmic content of pieces of popular music. The meter of such pieces is deter- mined of energy bursts in each band. We found that the meters of the pieces we analyzed were characterized

Hall, Rachel W.

377

Broadband precision wavelength meter based on a stepping FabryProt interferometer  

E-Print Network [OSTI]

Broadband precision wavelength meter based on a stepping Fabry­Pérot interferometer T. J. Scholl. INTRODUCTION Wavelength meters based on Michelson or Fizeau inter- ferometers have long been the standard a more general laser wavelength meter in which the FP ring pattern was employed to compare

Rehse, Steven J.

378

Meter Any Wire, Anywhere by Virtualizing the Voltage Channel Thomas Schmid, David Culler, Prabal Dutta  

E-Print Network [OSTI]

Meter Any Wire, Anywhere by Virtualizing the Voltage Channel Thomas Schmid, David Culler, Prabal}@eecs.umich.edu culler@cs.berkeley.edu Abstract AC power meters require both voltage and current to be sampled physical proximity and fed into a single power metering de- vice. In this paper, we explore the viability

Dutta, Prabal

379

Behavioral/Systems/Cognitive Selective Neuronal Entrainment to the Beat and Meter  

E-Print Network [OSTI]

Behavioral/Systems/Cognitive Selective Neuronal Entrainment to the Beat and Meter Embedded Fundamental to the experience of music, beat and meter perception refers to the perception of periodicities the spontaneous building of beat and meter hypothesized to emerge from the selective entrainment of neuronal

380

RIS-M-2243 THE RADIOCHROMIC DYE FILM DOSE METER AS A POSSIBLE TEST OF PARTICLE  

E-Print Network [OSTI]

RIS?-M-2243 THE RADIOCHROMIC DYE FILM DOSE METER AS A POSSIBLE TEST OF PARTICLE TRACK THEORY Johnny-film radlochromlc dye cyanide plastic dose meter to Ionizing radiation of electrons and heavy charged particles - 1. INTRODUCTION The radiochromic dye cyanide film dose meter has been investigated as a pos- sible

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

TRACKING THE "ODD": METER INFERENCE IN A CULTURALLY DIVERSE MUSIC CORPUS  

E-Print Network [OSTI]

TRACKING THE "ODD": METER INFERENCE IN A CULTURALLY DIVERSE MUSIC CORPUS Andre Holzapfel New York, containing a variety of meter types. We demonstrate that by adapting the model to specific styles, we can track beats and down- beats in odd meter types like 9/8 or 7/8 with an accuracy significantly improved

382

C-Meter: A Framework for Performance Analysis of Computing Clouds  

E-Print Network [OSTI]

C-Meter: A Framework for Performance Analysis of Computing Clouds Nezih Yigitbasi, Alexandru Iosup virtualization and network communications overheads. To address these issues, we have designed and implemented C-Meter of computing clouds. Then, we present the architecture of the C-Meter framework and discuss several resource

Iosup, Alexandru

383

Infants Prefer the Musical Meter of Their Own Culture: A Cross-Cultural Comparison  

E-Print Network [OSTI]

Infants Prefer the Musical Meter of Their Own Culture: A Cross-Cultural Comparison Gaye Soley to determine whether cultural background would influence their preferences for musical meter. In Experiment 1, American infants preferred Western over Balkan meter, whereas Turkish infants, who were familiar with both

Ahmad, Sajjad

384

DESIGN OF INTELLIGENT CONDUCTIVITY METER BASED ON MSP430F149  

E-Print Network [OSTI]

DESIGN OF INTELLIGENT CONDUCTIVITY METER BASED ON MSP430F149 Yaoguang Wei, Jianqing Wang, Daoliang are agriculture information technology. dliangl@cau.edu.cn Abstract: An intelligent conductivity meter based on MSP430F149 microcontroller was proposed in this paper. The intelligent conductive meter was composed

385

Finding Meter in Music Using an Autocorrelation Phase Matrix and Shannon Douglas Eck  

E-Print Network [OSTI]

Finding Meter in Music Using an Autocorrelation Phase Matrix and Shannon Entropy Douglas Eck. This approach yields a good model for predicting the meter of a piece of music. Finally we can use the phase information in the matrix to align a can- didate meter with music, making it possible to perform beat

Eck, Doug

386

meters in CO2 euthanasia chambers. All CO2 euthanasia chambers in both  

E-Print Network [OSTI]

meters in CO2 euthanasia chambers. All CO2 euthanasia chambers in both the facilities and laboratories will need flow meters. ULAR is currently in the process of identifying a cost-effective, accurate, and durable flow meter to install in all of the CO2 chambers in all of the vivaria. When a specific model

Bushman, Frederic

387

A Scalable Soft Spot Analysis Methodology for Compound Noise Effects in Nano-meter Circuits  

E-Print Network [OSTI]

A Scalable Soft Spot Analysis Methodology for Compound Noise Effects in Nano-meter Circuits Chong@ece.ucsd.edu ABSTRACT Circuits using nano-meter technologies are becoming increasingly vulnerable to signal interference methodology to study the vulnerability of digital ICs exposed to nano-meter noise and transient soft errors

California at San Diego, University of

388

Principle and implementations of a refracto-nephelo-turbidi-meter for  

E-Print Network [OSTI]

1 Principle and implementations of a refracto-nephelo-turbidi-meter for seawater measurements B of physical oceanography requires a compact high-resolution in-situ salino-turbidi-meter to measure these two the requirements and challenges of refracto-turbidi-meter design from their measurement principles and correlations

Paris-Sud XI, Université de

389

Design study of 8 meter monolithic mirror UV/optical space telescope H. Philip Stahl  

E-Print Network [OSTI]

Design study of 8 meter monolithic mirror UV/optical space telescope H. Philip Stahl NASA Marshall Space Flight Center, Huntsville, AL 35812 ABSTRACT The planned Ares V launch vehicle with its 10 meter to 8 meter class monolithic primary mirror telescope to Sun-Earth L2 using an Ares V. Specific

Sirianni, Marco

390

Behavioral/Systems/Cognitive Tagging the Neuronal Entrainment to Beat and Meter  

E-Print Network [OSTI]

Behavioral/Systems/Cognitive Tagging the Neuronal Entrainment to Beat and Meter Sylvie Nozaradan,1 (BRAMS), Universite´ de Montre´al, Quebec C.P. 6128 H3C 3J7, Canada Feeling the beat and meter to the beat frequency. Most importantly, we found that meter imagery elicits an additional frequency tuned

391

A model of the VU (volume-unit) meter, with speech applications Bryce Lobdell  

E-Print Network [OSTI]

A model of the VU (volume-unit) meter, with speech applications Bryce Lobdell Jont Allen Beckman Institute, University of Illinois Urbana, IL 61801 (October 11, 2006) Running title: volume unit meter usage ABSTRACT The Volume Unit (VU) meter, used in speech research prior to the ad- vent of computers and modern

Allen, Jont

392

Gemini: A Non-Invasive, Energy-Harvesting True Power Meter Bradford Campbell and Prabal Dutta  

E-Print Network [OSTI]

Gemini: A Non-Invasive, Energy-Harvesting True Power Meter Bradford Campbell and Prabal Dutta,prabal}@umich.edu Abstract--Power meters are critical for submetering loads in residential and commercial settings, but high by proposing non-invasive meters that easily clip onto a wire, or stick onto a circuit breaker, to perform

Dutta, Prabal

393

Reference Directions for a Sound Level Meter , M.R. Vaabenb  

E-Print Network [OSTI]

0 and 90 Reference Directions for a Sound Level Meter E. Aflaloa , M.R. Vaabenb , P. Pourtaua , D the requirements of the IEC 61672 standard on sound level meters taking into account noise incidence from level meter must be pointed at the source according to standard IEC 60651. The purpose of the paper

Paris-Sud XI, Université de

394

MSET modeling of Crystal River-3 venturi flow meters.  

SciTech Connect (OSTI)

The analysis of archived Crystal River-3 feedwater flow data reveals a slow and steady degradation of the flow meter measurements during the 1992/1993 operating cycle. MSET can reliably estimate the true flow rate and quantify the degree of departure between the indicated signal and the true flow rate with high accuracy. The MSET computed flow rate could, in principle, be used to provide an improved estimate of the reactor power and hence avoid the revenue loss associated with derating the reactor based on a faulty feedwater flow rate indication.

Bockhorst, F. K.; Gross, K. C.; Herzog, J. P.; Wegerich, S. W.

1998-01-05T23:59:59.000Z

395

The Coldest Cubic Meter in the Known Universe  

E-Print Network [OSTI]

CUORE is a 741 kg array of TeO2 bolometers that will search for the neutrinoless double beta decay of 130Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso in Italy, where it will begin taking data in 2015. The CUORE cryostat will cool several metric tonnes of material to below 1 K and the CUORE detector itself will operate at a typical temperature of 10 mK. At this temperature, the CUORE detector will be the coldest contiguous cubic meter in the known Universe.

Jonathan Ouellet

2014-10-14T23:59:59.000Z

396

Meter-baseline tests of sterile neutrinos at Daya Bay  

E-Print Network [OSTI]

We explore the sensitivity of an experiment at the Daya Bay site, with a point radioactive source and a few meter baseline, to neutrino oscillations involving one or more eV mass sterile neutrinos. We find that within a year, the entire 3+2 and 1+3+1 parameter space preferred by global fits can be excluded at the 3\\sigma level, and if an oscillation signal is found, the 3+1 and 3+2 scenarios can be distinguished from each other at more than the 3\\sigma level provided one of the sterile neutrinos is lighter than 0.5 eV.

Y. Gao; D. Marfatia

2013-05-07T23:59:59.000Z

397

The Coldest Cubic Meter in the Known Universe  

E-Print Network [OSTI]

CUORE is a 741 kg array of TeO2 bolometers that will search for the neutrinoless double beta decay of 130Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso in Italy, where it will begin taking data in 2015. The CUORE cryostat will cool several metric tonnes of material to below 1 K and the CUORE detector itself will operate at a typical temperature of 10 mK. At this temperature, the CUORE detector will be the coldest contiguous cubic meter in the known Universe.

Ouellet, Jonathan

2014-01-01T23:59:59.000Z

398

2010 Assessment of Demand Response and Advanced Metering - Staff Report  

Broader source: Energy.gov (indexed) [DOE]

2010 Assessment of Demand Response and Advanced Metering Staff Report Federal Energy Regulatory Commission February 2011 The opinions and views expressed in this staff report do not necessarily represent those of the Federal Energy Regulatory Commission, its Chairman, or individual Commissioners, and are not binding on the Commission. ACKNOWLEDGEMENTS Federal Energy Regulatory Commission Staff Team Dean Wight, Team Lead Caroline Daly David Kathan Michael P. Lee Kamaria Martin Pamela Silberstein Michael Tita Rebecca Vertes Z, INC. Team Bryan Templeton (Z, INC.) Valerie Richardson (KEMA) Will Gifford (KEMA) Christopher Elsner (Z, INC.) Matthew S. Pettit (KEMA) Geoff Barker (KEMA) Ron Chebra (KEMA) TABLE OF CONTENTS Executive Summary

399

Preliminaries Conserved Interval Distance between Non-trivial  

E-Print Network [OSTI]

Outline Preliminaries Results Conclusion Conserved Interval Distance between Non-trivial Genomes.Rizzi@unitn.it August the 16th Guillaume Blin, Romeo Rizzi Conserved Interval Distance between Non-trivial Genomes #12 Guillaume Blin, Romeo Rizzi Conserved Interval Distance between Non-trivial Genomes #12;Outline

Blin, Guillaume

400

ASYMPTOTIC BEHAVIOR OF THE ENTROPY OF INTERVAL MAPS  

E-Print Network [OSTI]

ASYMPTOTIC BEHAVIOR OF THE ENTROPY OF INTERVAL MAPS ALEXANDER BLOKH AND JOZEF BOBOK Abstract. We obtain upper estimates on the entropy of interval maps of given modality and Sharkovskii type. Following our results we formulate a conjecture on asymptotic behavior of the entropy of interval maps. 1

Blokh, Alexander

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Thoron detection with an active Radon exposure meterFirst results  

SciTech Connect (OSTI)

For state-of-the-art discrimination of Radon and Thoron several measurement techniques can be used, such as active sampling, electrostatic collection, delayed coincidence method, and alpha-particle-spectroscopy. However, most of the devices available are bulky and show high power consumption, rendering them unfeasible for personal exposition monitoring. Based on a Radon exposure meter previously realized at the Helmholtz Center Munich (HMGU), a new electronic prototype for Radon/Thoron monitoring is currently being developed, which features small size and weight. Operating with pin-diode detectors, the low-power passive-sampling device can be used for continuous concentration measurements, employing alpha-particle-spectroscopy and coincidence event registration to distinguish decays originating either from Radon or Thoron isotopes and their decay products. In open geometry, preliminary calibration measurements suggest that one count per hour is produced by a 11?Bq?m{sup ?3} Radon atmosphere or by a 15?Bq?m{sup ?3} Thoron atmosphere. Future efforts will concentrate on measurements in mixed Radon/Thoron atmospheres.

Irlinger, J., E-mail: josef.irlinger@helmholtz-muenchen.de; Wielunski, M.; Rhm, W. [ISS, Helmholtz Center Munich, Research Center for Environment and Health, 85764 Neuherberg (Germany)] [ISS, Helmholtz Center Munich, Research Center for Environment and Health, 85764 Neuherberg (Germany)

2014-02-15T23:59:59.000Z

402

Hospital Triage in First Hours After Nuclear or Radiological...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Hospital Triage in the First 24 Hours after a Nuclear or Radiological Disaster Medical professionals with the Radiation Emergency Assistance CenterTraining Site (REACTS) at the...

403

Delayed Start or Cancellation of Business Hours | Argonne National...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

if you have questions. When regular business hours are suspended The laboratory may not conduct regular operations because of inclement weather. In this case, employees are not...

404

The magnetic flywheel flow meter: Theoretical and experimental contributions  

SciTech Connect (OSTI)

The development of contactless flow meters is an important issue for monitoring and controlling of processes in different application fields, like metallurgy, liquid metal casting, or cooling systems for nuclear reactors and transmutation machines. Shercliff described in his book The Theory of Electromagnetic Flow Measurement, Cambridge University Press, 1962 a simple and robust device for contact-less measurements of liquid metal flow rates which is known as magnetic flywheel. The sensor consists of several permanent magnets attached on a rotatable soft iron plate. This arrangement will be placed closely to the liquid metal flow to be measured, so that the field of the permanent magnets penetrates into the fluid volume. The flywheel will be accelerated by a Lorentz force arising from the interaction between the magnetic field and the moving liquid. Steady rotation rates of the flywheel can be taken as a measure for the mean flow rate inside the fluid channel. The present paper provides a detailed theoretical description of the sensor in order to gain a better insight into the functional principle of the magnetic flywheel. Theoretical predictions are confirmed by corresponding laboratory experiments. For that purpose, a laboratory model of such a flow meter was built and tested on a GaInSn-loop under various test conditions.

Buchenau, D., E-mail: d.buchenau@hzdr.de; Galindo, V.; Eckert, S. [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, Bautzner Landstrae 400, 01328 Dresden (Germany)

2014-06-02T23:59:59.000Z

405

Meter scale plasma source for plasma wakefield experiments  

SciTech Connect (OSTI)

High accelerating gradients generated by a high density electron beam moving through plasma has been used to double the energy of the SLAC electron beam [1]. During that experiment, the electron current density was high enough to generate its own plasma without significant head erosion. In the newly commissioned FACET facility at SLAC, the peak current will be lower and without pre-ionization, head erosion will be a significant challenge for the planned experiments. In this work we report on our design of a meter scale plasma source for these experiments to effectively avoid the problem of head erosion. The plasma source is based on a homogeneous metal vapor gas column that is generated in a heat pipe oven [2]. A lithium oven over 30 cm long at densities over 10{sup 17} cm{sup -3} has been constructed and tested at UCLA. The plasma is then generated by coupling a 10 TW short pulse Ti:Sapphire laser into the gas column using an axicon lens setup. The Bessel profile of the axicon setup creates a region of high intensity that can stretch over the full length of the gas column with approximately constant diameter. In this region of high intensity, the alkali metal vapor is ionized through multi-photon ionization process. In this manner, a fully ionized meter scale plasma of uniform density can be formed. Methods for controlling the plasma diameter and length will also be discussed.

Vafaei-Najafabadi, N.; Shaw, J. L.; Marsh, K. A.; Joshi, C.; Hogan, M. J. [Department of Electrical Engineering, University of California Los Angeles, Los Angeles, CA 90095 (United States); SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States)

2012-12-21T23:59:59.000Z

406

Microsoft Word - CX-OTEC-West-JohnDaySub-MeterProjectFY13_WEB.doc  

Broader source: Energy.gov (indexed) [DOE]

Walker Miller Walker Miller Electrical Engineer - TPCF-PASCO Proposed Action: Revenue Meter Replacement at Oregon Trail Electric Co-op's (OTEC's) West John Day Substation PP&A Project No: 2595 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.7 Electronic Equipment Location: Grant County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to replace an old JEM1 revenue meter at OTEC's West John Day Substation. The meter would be replaced with a new JEMStar meter inside OTEC's existing control house. The new meter would allow BPA to meter load from a new transformer OTEC is installing. This meter will be installed by BPA personnel and it will remain the property and responsibility of BPA.

407

Analysis of PG&E`s residential end-use metered data to improve electricity demand forecasts -- final report  

SciTech Connect (OSTI)

This report summarizes findings from a unique project to improve the end-use electricity load shape and peak demand forecasts made by the Pacific Gas and Electric Company (PG&E) and the California Energy Commission (CEC). First, the direct incorporation of end-use metered data into electricity demand forecasting models is a new approach that has only been made possible by recent end-use metering projects. Second, and perhaps more importantly, the joint-sponsorship of this analysis has led to the development of consistent sets of forecasting model inputs. That is, the ability to use a common data base and similar data treatment conventions for some of the forecasting inputs frees forecasters to concentrate on those differences (between their competing forecasts) that stem from real differences of opinion, rather than differences that can be readily resolved with better data. The focus of the analysis is residential space cooling, which represents a large and growing demand in the PG&E service territory. Using five years of end-use metered, central air conditioner data collected by PG&E from over 300 residences, we developed consistent sets of new inputs for both PG&E`s and CEC`s end-use load shape forecasting models. We compared the performance of the new inputs both to the inputs previously used by PG&E and CEC, and to a second set of new inputs developed to take advantage of a recently added modeling option to the forecasting model. The testing criteria included ability to forecast total daily energy use, daily peak demand, and demand at 4 P.M. (the most frequent hour of PG&E`s system peak demand). We also tested the new inputs with the weather data used by PG&E and CEC in preparing their forecasts.

Eto, J.H.; Moezzi, M.M.

1993-12-01T23:59:59.000Z

408

California Solar Initiative (CSI) Thermal Program Metering Installation Guide Purpose: The purpose of this metering installation guide is to provide participating eligible contractors  

E-Print Network [OSTI]

1 California Solar Initiative (CSI) Thermal Program Metering Installation Guide Purpose: The purpose of this metering installation guide is to provide participating eligible contractors in the CSI-Thermal to the mixing valve. Place the hot sensor on the pipe between the solar tank and the backup water heater. #12

409

The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California  

E-Print Network [OSTI]

net metering, and policies for supporting solar deployment.net metering, and policies for supporting solar deployment.Energy Policy, 36: MRW & Associates. 2007. Solar PV and

Darghouth, Naim

2010-01-01T23:59:59.000Z

410

Credit Based; Beginning Swimming Credit/Hours Class  

E-Print Network [OSTI]

Center Pool Course Description: Beginning swimming skills and water safety. Prerequisites: Must about experience at the meet. 3) Swim laps during open swim/lap swim at MSU pool. A sheet will be postedCredit Based; Beginning Swimming Credit/Hours Class Title Lead Instructor Phone Email Office Hours

Maxwell, Bruce D.

411

Steam turbine-generator outage interval extension  

SciTech Connect (OSTI)

In the industry`s growing competitive climate, utilities are seeking ways to tap the economic benefits to be derived from maximizing intervals between major turbine-generator (T-G) inspections and overhauls--while ensuring protection of these assets. EPRI and others have developed a substantial body of technology which addresses many of the condition assessment issues that underlie T-G inspection and overhaul decisions. Examples include remaining life determination of critical components such as rotors and blades. While the initial focus of this technology had previously been to support T-G run-repair-replace decision making, this technology can also serve as a basis for run-inspect decisions. This paper describes EPRI`s initiative to develop and implement a T-G Health Management System. By providing key status reports reflecting the on-line health of critical components, in terms of life consumption, performance degradation and probability of failure, this system will provide a means to justify extending T-G operations between inspections and overhauls.

McCloskey, T.H. [Electric Power Research Institute, Palo Alto, CA (United States); Pollard, M. [Carolina Power & Light Company, Raleigh, NC (United States); Dewey, R.; Roemer, M. [Stress Technology Inc., Rochester, NY (United States)

1996-07-01T23:59:59.000Z

412

General Education and Major Coursework: Credit Hours General Education and Major Coursework: Credit Hours ENGN 110 2 ECE 111 2  

E-Print Network [OSTI]

: 128 ** Meets philosophy and ethics general education requirement. Electrical engineering majors mustGeneral Education and Major Coursework: Credit Hours General Education and Major Coursework: Credit (C or better required) 3 PHYS 231N 4 COMM 101R 3 General Education and Major Coursework: Credit Hours

413

Trillion Cubic Feet Billion Cubic Meters Residential Commercial  

Gasoline and Diesel Fuel Update (EIA)

2 2 4 6 8 10 0 50 100 150 200 250 Trillion Cubic Feet Billion Cubic Meters Residential Commercial Industrial Electric Utilities 1930 1935 1940 1945 1950 1955 1960 1965 1970 1980 1985 1990 1995 1975 2000 Note: In 1996, consumption of natural gas for agricultural use is classified as industrial use. In 1995 and earlier years, agricultural use was classified as commercial use. Sources: 1930-1975: Bureau of Mines, Minerals Yearbook, "Natural Gas" chapter. 1976-1978: Energy Information Administration (EIA), Energy Data Reports, Natural Gas Annual. 1979: EIA, Natural Gas Production and Consumption, 1979. 1980-1996: Form EIA- 176, "Annual Report of Natural and Supplemental Gas Supply and Disposition" and Form EIA-759, "Monthly Power Plant Report." 23. Natural Gas Delivered to Consumers in the United States, 1930-1996 Figure

414

ESB Smart Meter Projects (Smart Grid Project) (Limerick, Ireland) | Open  

Open Energy Info (EERE)

Projects (Smart Grid Project) (Limerick, Ireland) Projects (Smart Grid Project) (Limerick, Ireland) Jump to: navigation, search Project Name ESB Smart Meter Projects Country Ireland Headquarters Location Limerick, Ireland Coordinates 52.663857°, -8.626773° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":52.663857,"lon":-8.626773,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

415

Microsoft Word - CX-Paisley_Meter_08Aug2013.doc  

Broader source: Energy.gov (indexed) [DOE]

3 3 REPLY TO ATTN OF: KEC-4 SUBJECT: Environmental Clearance Memorandum Robert Trismen Project Manager -TEP-CSB-1 Proposed Action: Paisley Geothermal Integration Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.7 Electronic Equipment Location: Lake County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to integrate Surprise Valley Electrification Corporation's (SVEC) 3.65-megawatt Paisley Geothermal Project into BPA's balancing authority (BA) in response to a SVEC small generator interconnection request. The proposed point of interconnection would be at SVEC's existing Paisley Substation. In order to integrate the proposed geothermal generation project, BPA would provide and review metering drawings,

416

Positron Beam Propagation in a Meter Long Plasma Channel  

SciTech Connect (OSTI)

Recent experiments and simulations have shown that positron beams propagating in plasmas can be focused and also create wakes with large accelerating gradients. For similar parameters, the wakes driven by positron beams are somewhat smaller compared to the case of an electron beam. Simulations have shown that the wake amplitude can be increased if the positron beam is propagated in a hollow plasma channel (Ref. 1). This paper, compares experimentally, the propagation and beam dynamics of a positron beam in a meter scale homogeneous plasma, to a positron beam hollow channel plasma. The results show that positron beams in hollow channels are less prone to distortions and deflections. Hollow channels were observed to guide the positron beam onto the channel axis. Beam energy loss was also observed implying the formation of a large wake amplitude. The experiments were carried out as part of the E-162 plasma wakefield experiments at SLAC.

Marsh, K.A.; Blue, B.E.; Clayton, C.E.; Joshi, C.; Mori, W.B.; /UCLA; Decker, F.-J.; Hogan, M.J.; Iverson, R.; O'Connell, C.; Raimondi, P.; Siemann, Robert H.; Walz, D.; /SLAC; Katsouleas, T.C.; Muggli, P.; /Southern California U.

2008-03-17T23:59:59.000Z

417

Quantum Metrology: Towards an alternative definition for the meter  

E-Print Network [OSTI]

The motivation for this article came from an attempt to give an alternative definition for the meter, the SI unit for measuring length. As a starting point towards this goal, in this piece of work we present the underlying theory behind our approach which uses ideas from quantum field theory and noncommutative geometry, in particular the notion of an odd K-cycle which is based on the Dirac operator (and its inverse, the Dirac propagator). Using (the perhaps more familiar) physics terminology, the key point in our strategy is this: instead of measuring length directly in space-time we measure the "algebraic (spectral) length" in the space of the corresponding quantum states of some particle (fermion) acted upon by the Dirac propagator. This approach shares the spirit of the unanimus vote of the 24th General Conference of Standards and Measures (21st October 2011) in Serves, France for the redefinition of the fundamental units using Planck's constant.

Ioannis P. Zois

2012-03-05T23:59:59.000Z

418

"YEAR","MONTH","STATE","UTILITY CODE","UTILITY NAME","RESIDENTIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL PHOTOVOLTAIC ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","TOTAL PHOTOVOLTAIC INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","COMMERCIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","INDUSTRIAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","TRANSPORTATIONPHOTOVOLTAIC NET METERING CUSTOMER COUNT","TOTAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","RESIDENTIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION WIND ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL WIND INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL WIND INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL WIND INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION WIND INSTALLED NET METERING CAPACITY (MW)","TOTAL WIND INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL WIND NET METERING CUSTOMER COUNT","COMMERCIAL WIND NET METERING CUSTOMER COUNT","INDUSTRIAL WIND NET METERING CUSTOMER COUNT","TRANSPORTATION WIND NET METERING CUSTOMER COUNT","TOTAL WIND NET METERING CUSTOMER COUNT","RESIDENTIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL OTHER INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL OTHER INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL OTHER INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION OTHER INSTALLED NET METERING CAPACITY (MW)","TOTAL OTHER INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL OTHER NET METERING CUSTOMER COUNT","COMMERCIAL OTHER NET METERING CUSTOMER COUNT","INDUSTRIAL OTHER NET METERING CUSTOMER COUNT","TRANSPORTATION OTHER NET METERING CUSTOMER COUNT","TOTAL OTHER NET METERING CUSTOMER COUNT","RESIDENTIAL TOTAL ENERGY SOLD BACK TO THE UTILITY (MWh)","COMMERCIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION TOTAL INSTALLED NET METERING CAPACITY (MW)","TOTAL INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL TOTAL NET METERING CUSTOMER COUNT","COMMERCIAL TOTAL NET METERING CUSTOMER COUNT","INDUSTRIAL TOTAL NET METERING CUSTOMER COUNT","TRANSPORTATION TOTAL NET METERING CUSTOMER COUNT","TOTAL NET METERING CUSTOMER COUNT","RESIDENTIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","COMMERCIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","INDUSTRIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TRANSPORTATION ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TOTAL ELECTRIC ENERGY SOLD BACK TO THE UTILITYFOR ALL STATES SERVED(MWh)","RESIDENTIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","COMMERCIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INDUSTRIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","TRANSPORTATION INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","RESIDENTIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","COMMERCIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","INDUSTRIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","TRANSPORTATION NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","NET METERING CUSTOMER COUNT FOR ALL STATES SERVED"  

U.S. Energy Information Administration (EIA) Indexed Site

TRANSPORTATIONPHOTOVOLTAIC NET METERING CUSTOMER COUNT","TOTAL PHOTOVOLTAIC NET METERING CUSTOMER COUNT","RESIDENTIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION WIND ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL WIND ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL WIND INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL WIND INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL WIND INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION WIND INSTALLED NET METERING CAPACITY (MW)","TOTAL WIND INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL WIND NET METERING CUSTOMER COUNT","COMMERCIAL WIND NET METERING CUSTOMER COUNT","INDUSTRIAL WIND NET METERING CUSTOMER COUNT","TRANSPORTATION WIND NET METERING CUSTOMER COUNT","TOTAL WIND NET METERING CUSTOMER COUNT","RESIDENTIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","COMMERCIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION OTHER ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL OTHER ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL OTHER INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL OTHER INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL OTHER INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION OTHER INSTALLED NET METERING CAPACITY (MW)","TOTAL OTHER INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL OTHER NET METERING CUSTOMER COUNT","COMMERCIAL OTHER NET METERING CUSTOMER COUNT","INDUSTRIAL OTHER NET METERING CUSTOMER COUNT","TRANSPORTATION OTHER NET METERING CUSTOMER COUNT","TOTAL OTHER NET METERING CUSTOMER COUNT","RESIDENTIAL TOTAL ENERGY SOLD BACK TO THE UTILITY (MWh)","COMMERCIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","INDUSTRIAL TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TRANSPORTATION TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","TOTAL ELECTRIC ENERGY SOLD BACK (MWh)","RESIDENTIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","COMMERCIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","INDUSTRIAL TOTAL INSTALLED NET METERING CAPACITY (MW)","TRANSPORTATION TOTAL INSTALLED NET METERING CAPACITY (MW)","TOTAL INSTALLED NET METERING CAPACITY (MW)","RESIDENTIAL TOTAL NET METERING CUSTOMER COUNT","COMMERCIAL TOTAL NET METERING CUSTOMER COUNT","INDUSTRIAL TOTAL NET METERING CUSTOMER COUNT","TRANSPORTATION TOTAL NET METERING CUSTOMER COUNT","TOTAL NET METERING CUSTOMER COUNT","RESIDENTIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","COMMERCIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","INDUSTRIAL ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TRANSPORTATION ELECTRIC ENERGY SOLD BACK TO THE UTILITY FOR ALL STATES SERVED(MWh)","TOTAL ELECTRIC ENERGY SOLD BACK TO THE UTILITYFOR ALL STATES SERVED(MWh)","RESIDENTIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","COMMERCIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INDUSTRIAL INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","TRANSPORTATION INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","INSTALLED NET METERING CAPACITY FOR ALL STATES SERVED(MW)","RESIDENTIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","COMMERCIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","INDUSTRIAL NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","TRANSPORTATION NET METERING CUSTOMER COUNT FOR ALL STATES SERVED","NET METERING CUSTOMER COUNT FOR ALL STATES SERVED"

419

NIST Releases Test Framework for Upgrading of Smart Meters | Department of  

Broader source: Energy.gov (indexed) [DOE]

NIST Releases Test Framework for Upgrading of Smart Meters NIST Releases Test Framework for Upgrading of Smart Meters NIST Releases Test Framework for Upgrading of Smart Meters July 12, 2012 - 10:46am Addthis The National Institute of Standards and Technology (NIST) has released a draft set of guidelines that will help utilities test their procedures for upgrading their smart meters securely from a remote location and determine whether their procedures conform with the National Electrical Manufacturers Association (NEMA) Standard for Smart Grid Upgradeability. Available now for public comment, the Advanced Metering Infrastructure Smart Meter Upgradeability Test Framework includes test procedures and detailed steps for conducting the test, reviewing results, and producing records to assess and report on these results.

420

Hydro-Québec Net Metering (Quebec, Canada) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Hydro-Québec Net Metering (Quebec, Canada) Hydro-Québec Net Metering (Quebec, Canada) Hydro-Québec Net Metering (Quebec, Canada) < Back Eligibility Commercial Agricultural Residential Savings Category Buying & Making Electricity Solar Program Info Funding Source Hydro-Quebec State Quebec Program Type Net Metering In line with Hydro-Québec's commitment to the environment and sustainable development, Hydro-Québec is supporting self-generation with a new rate offering: the net metering option. This option reflects a broad approach to energy efficiency. It is both environmentally friendly and advantageous for self-generators seeking to optimize their energy management. Net metering provides a way to act on convictions by using renewable energy and state-of-the-art technology to truly take control of consumption

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Microsoft Word - CX-BentonCoPUD-FinleySubstationMeterProject_FY13_WEB.doc  

Broader source: Energy.gov (indexed) [DOE]

John Roeder John Roeder Contractor - TEP-CSB-1 Proposed Action: Revenue Meter Replacement at Benton County Public Utility District's (PUD) Finley Substation PP&A Project No: 2594 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.7 Electronic Equipment Location: Benton County, Washington Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to replace an existing JEM1 revenue meter with a new JEMStar revenue meter within an existing meter rack at Benton County PUD's Finley Substation. BPA would own the rack and meter. No ground disturbance or alteration to the meter house would occur. Findings: BPA has determined that the proposed action complies with Section 1021.410 and

422

Vids4Grids: Smart Meters and Super Cables | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Grids: Smart Meters and Super Cables Grids: Smart Meters and Super Cables Vids4Grids: Smart Meters and Super Cables March 14, 2011 - 4:46pm Addthis This episode of Vids 4 Grids will take us to Itron's smart meter factory in West Union, SC where we will learn the role smart meters play in the Smart Grid. Deborah J. Buterbaugh Energy Project Specialist at National Energy Technology Laboratory What does this mean for me? Smart meters allow consumers to get real time information about their energy usage. Super cables help provide more reliable electricity to your home. In January we introduced you to the Vids4Grids project, a series of videos targeting students in high school and starting college. Through integration into curricula and online posting for open viewing, the project aims to increase awareness and create interest in power systems careers to help

423

Vids4Grids: Smart Meters and Super Cables | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Vids4Grids: Smart Meters and Super Cables Vids4Grids: Smart Meters and Super Cables Vids4Grids: Smart Meters and Super Cables March 14, 2011 - 4:46pm Addthis This episode of Vids 4 Grids will take us to Itron's smart meter factory in West Union, SC where we will learn the role smart meters play in the Smart Grid. Deborah J. Buterbaugh Energy Project Specialist at National Energy Technology Laboratory What does this mean for me? Smart meters allow consumers to get real time information about their energy usage. Super cables help provide more reliable electricity to your home. In January we introduced you to the Vids4Grids project, a series of videos targeting students in high school and starting college. Through integration into curricula and online posting for open viewing, the project aims to increase awareness and create interest in power systems careers to help

424

Have You Used an Electric Meter to Measure Your Energy Use? | Department of  

Broader source: Energy.gov (indexed) [DOE]

Have You Used an Electric Meter to Measure Your Energy Use? Have You Used an Electric Meter to Measure Your Energy Use? Have You Used an Electric Meter to Measure Your Energy Use? December 10, 2009 - 7:30am Addthis This week, you read about using an electric meter to measure and manage your energy use. Using a meter could make you more conscious of exactly what items are costing you the most money. Plus, it can be kind of fun to put actual numbers to the various items in your home. Have you used an electric meter to measure your energy use? Tell us about your experience. Each Thursday, you have the chance to share your thoughts on a question about energy efficiency or renewable energy for consumers. E-mail your responses to the Energy Saver team at consumer.webmaster@nrel.gov. Addthis Related Articles You Can't Manage Energy Use That You Don't Measure

425

VP 100: Smart Meters Will Help Customers Avoid High Electric Bills |  

Broader source: Energy.gov (indexed) [DOE]

Smart Meters Will Help Customers Avoid High Electric Bills Smart Meters Will Help Customers Avoid High Electric Bills VP 100: Smart Meters Will Help Customers Avoid High Electric Bills October 4, 2010 - 3:00pm Addthis An employee installs a smart meter as part of a smart grid initiative by EPB. The project is supporting 390 jobs in the Chattanooga area. | Photo courtesy of EPB An employee installs a smart meter as part of a smart grid initiative by EPB. The project is supporting 390 jobs in the Chattanooga area. | Photo courtesy of EPB Kevin Craft What are the key facts? EPB will install approximately 170,000 smart meters and 1,500 automated switches. They have the potential to provide a $300 million value to EPB and customers over a ten-year period. "Last winter I received a call from my son saying he had a $400 electric

426

VP 100: Smart Meters Will Help Customers Avoid High Electric Bills |  

Broader source: Energy.gov (indexed) [DOE]

VP 100: Smart Meters Will Help Customers Avoid High Electric Bills VP 100: Smart Meters Will Help Customers Avoid High Electric Bills VP 100: Smart Meters Will Help Customers Avoid High Electric Bills October 4, 2010 - 3:00pm Addthis An employee installs a smart meter as part of a smart grid initiative by EPB. The project is supporting 390 jobs in the Chattanooga area. | Photo courtesy of EPB An employee installs a smart meter as part of a smart grid initiative by EPB. The project is supporting 390 jobs in the Chattanooga area. | Photo courtesy of EPB Kevin Craft What are the key facts? EPB will install approximately 170,000 smart meters and 1,500 automated switches. They have the potential to provide a $300 million value to EPB and customers over a ten-year period. "Last winter I received a call from my son saying he had a $400 electric

427

Mooring Motion Bias of Point-Doppler Current Meter Measurements Paul Freitag, Michael McPhaden, Chris Meinig, Patricia Plimpton  

E-Print Network [OSTI]

Mooring Motion Bias of Point-Doppler Current Meter Measurements Paul Freitag, Michael Mc). Until 1998 the moorings were instrumented with mechanical current meters (MCMs, either Vector Averaging Current Meters (VACM) or Vector Measuring Current Meters (VMCM)). Comparison with nearby subsurface 150 k

428

Four Current Meter Models Compared in Strong Currents in Drake Passage D. RANDOLPH WATTS, MAUREEN A. KENNELLY, KATHLEEN A. DONOHUE,  

E-Print Network [OSTI]

Four Current Meter Models Compared in Strong Currents in Drake Passage D. RANDOLPH WATTS, MAUREEN A February 2013, in final form 11 June 2013) ABSTRACT Seven current meters representing four models: two vector-measuring current meters (VMCMs), two Aanderaa recording current meter (RCM) 11s, two

Rhode Island, University of

429

Team Surpasses 1 Million Hours Safety Milestone | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Team Surpasses 1 Million Hours Safety Milestone Team Surpasses 1 Million Hours Safety Milestone Team Surpasses 1 Million Hours Safety Milestone October 30, 2013 - 12:00pm Addthis The Separations Process Research Unit Demolition Project Safety Committee meets regularly with employees and supervisors to discuss safety issues and reinforce safe work habits. The Separations Process Research Unit Demolition Project Safety Committee meets regularly with employees and supervisors to discuss safety issues and reinforce safe work habits. NISKAYUNA, N.Y. - Vigilance and dedication to safety led the EM program's disposition project team at the Separations Process Research Unit (SPRU) to achieve a milestone of one million hours - over two-and-a-half-years - without injury or illness resulting in time away from work.

430

Team Surpasses 1 Million Hours Safety Milestone | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Team Surpasses 1 Million Hours Safety Milestone Team Surpasses 1 Million Hours Safety Milestone Team Surpasses 1 Million Hours Safety Milestone October 30, 2013 - 12:00pm Addthis The Separations Process Research Unit Demolition Project Safety Committee meets regularly with employees and supervisors to discuss safety issues and reinforce safe work habits. The Separations Process Research Unit Demolition Project Safety Committee meets regularly with employees and supervisors to discuss safety issues and reinforce safe work habits. NISKAYUNA, N.Y. - Vigilance and dedication to safety led the EM program's disposition project team at the Separations Process Research Unit (SPRU) to achieve a milestone of one million hours - over two-and-a-half-years - without injury or illness resulting in time away from work.

431

DOE Awards Over a Billion Supercomputing Hours to Address Scientific  

Broader source: Energy.gov (indexed) [DOE]

Over a Billion Supercomputing Hours to Address Over a Billion Supercomputing Hours to Address Scientific Challenges DOE Awards Over a Billion Supercomputing Hours to Address Scientific Challenges January 26, 2010 - 12:00am Addthis Washington, DC. - The U.S. Department of Energy announced today that approximately 1.6 billion supercomputing processor hours have been awarded to 69 cutting-edge research projects through the Innovative and Novel Computational Impact on Theory and Experiment (INCITE) program. The INCITE program provides powerful resources to enable scientists and engineers to conduct cutting-edge research in just weeks or months rather than the years or decades needed previously. This facilitates scientific breakthroughs in areas such as climate change, alternative energy, life sciences, and materials science.

432

DOE Awards Over a Billion Supercomputing Hours to Address Scientific  

Broader source: Energy.gov (indexed) [DOE]

DOE Awards Over a Billion Supercomputing Hours to Address DOE Awards Over a Billion Supercomputing Hours to Address Scientific Challenges DOE Awards Over a Billion Supercomputing Hours to Address Scientific Challenges January 26, 2010 - 12:00am Addthis Washington, DC. - The U.S. Department of Energy announced today that approximately 1.6 billion supercomputing processor hours have been awarded to 69 cutting-edge research projects through the Innovative and Novel Computational Impact on Theory and Experiment (INCITE) program. The INCITE program provides powerful resources to enable scientists and engineers to conduct cutting-edge research in just weeks or months rather than the years or decades needed previously. This facilitates scientific breakthroughs in areas such as climate change, alternative energy, life

433

Balancing Authority Cooperation Concepts - Intra-Hour Scheduling  

SciTech Connect (OSTI)

The overall objective of this study was to understand, on an Interconnection-wide basis, the effects intra-hour scheduling compared to hourly scheduling. Moreover, the study sought to understand how the benefits of intra-hour scheduling would change by altering the input assumptions in different scenarios. This report describes results of three separate scenarios with differing key assumptions and comparing the production costs between hourly scheduling and 10-minute scheduling performance. The different scenarios were chosen to provide insight into how the estimated benefits might change by altering input assumptions. Several key assumptions were different in the three scenarios, however most assumptions were similar and/or unchanged among the scenarios.

Hunsaker, Matthew; Samaan, Nader; Milligan, Michael; Guo, Tao; Liu, Guangjuan; Toolson, Jacob

2013-03-29T23:59:59.000Z

434

DOE's Office of Science Awards 18 Million Hours of Supercomputing...  

Office of Environmental Management (EM)

Supercomputing Time to 15 Teams for Large-Scale Scientific Computing DOE's Office of Science Awards 18 Million Hours of Supercomputing Time to 15 Teams for Large-Scale Scientific...

435

SunShot Announces 24-Hour Solar Data Hackathon  

Broader source: Energy.gov [DOE]

SunShot will host a 24-hour solar data hackathon at the 2014 SunShot Grand Challenge Summit. Learn more over at the EERE blogand register here.

436

Pay and Leave Administration and Hours of Duty  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Order establishes requirements and responsibilities for the management of pay, including overtime and compensatory time, leave administration, and hours of duty. Cancels DOE O 322.1A. Canceled by DOE O 322.1C.

2005-01-14T23:59:59.000Z

437

Pay and Leave Administration and Hours of Duty  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The order establishes requirements and responsibilities for the management of pay, including overtime pay and compensatory time, leave administration, time and attendance reporting, and hours of duty. Cancels DOE O 322.1B and DOE O 535.1

2011-01-19T23:59:59.000Z

438

A study of the coherent structures and installation effects in an orifice flow meter  

E-Print Network [OSTI]

. Errors on the order of approximately 250 millions of dollar per year have been estimated for the natural gas industry. The urgent need to improve the accuracy has fueled basic research in the area of orifice flow meters. The objectives of this present... study were to analyze the coherent structures present in an orifice flow meter, and to examine the effect of a flow conditioner placed upstream of the orifice plate on the flow meter's accuracy, The coherent structures were measured by performing...

Pattabhi, Srikanth

2012-06-07T23:59:59.000Z

439

Metering and the New Federal Requirements of Energy Policy Act 2005  

E-Print Network [OSTI]

METERING AND THE NEW FEDERAL REQUIREMENTS OF ENERGY POLICY ACT 2005 Ab Ream Federal Energy Management Program U.S. Department of Energy Washington, DC Malcolm E. Verdict Energy Systems Laboratory Texas A&M University System College... Station, Texas ABSTRACT Section 103 of the Energy Policy Act of 2005 (EPAct 2005) (1) mandates the installation of meters and advanced electric meters on all Federal Buildings by 2012 using guidelines developed by the US Department of Energy...

Ream, A.; Verdict, M.

2006-01-01T23:59:59.000Z

440

NIST Special Publication 1039r1 Liquid Flow Meter Calibrations with the  

E-Print Network [OSTI]

NIST Special Publication 1039r1 Liquid Flow Meter Calibrations with the 0.1 L/s and the 2.5 L Publication 1039r1 Liquid Flow Meter Calibrations with the 0.1 L/s and the 2.5 L/s Piston Provers Jodie G. Technol. Spec. Publ. 1039r1, 55 pages (December 2013) CODEN: NSPUE2 #12;Liquid Flow Meter Calibrations

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Feasibility of the design of dual-lane ramp meters in Texas  

E-Print Network [OSTI]

Of Single- And Dual-Lane Ramp Meters . . . . . . . . . . . . . Microscopic Simulation Analysis Of Traffic Control And Operational Characteristics . 58 60 61 63 65 65 66 V STUDY RESULTS . . . 72 Gessner Street/Katy Freeway Single-Lane Ramp Meter... . . . . . . 108 APPENDIX A DUAL-LANE RAMP METER SURVEY AND MAILING LIST . . . . . . 112 APPENDIX B MAY 1997 QUEUE AND DEMAND VOLUME DATA FOR THE GESSNER STREET/KATY FREEWAY SINGLE-LANE RAMP . . . . 120 APPENDIX C PROPOSED GESSNER STREET/KATY FREEWAY DUAL...

Butorac, Marc Allen

2012-06-07T23:59:59.000Z

442

Genetic fuzzy logic approach to local ramp metering control using microscopic traffic simulation.  

E-Print Network [OSTI]

??Ramp metering, one of the most effective solutions for improving motorway traffic flows, is playing increasingly important role in traffic management systems. Because of its (more)

Yu, Xue Feng

2009-01-01T23:59:59.000Z

443

Uncertainty Analysis for a Virtual Flow Meter Using an Air-Handling Unit Chilled Water Valve  

SciTech Connect (OSTI)

A virtual water flow meter is developed that uses the chilled water control valve on an air-handling unit as a measurement device. The flow rate of water through the valve is calculated using the differential pressure across the valve and its associated coil, the valve command, and an empirically determined valve characteristic curve. Thus, the probability of error in the measurements is significantly greater than for conventionally manufactured flow meters. In this paper, mathematical models are developed and used to conduct uncertainty analysis for the virtual flow meter, and the results from the virtual meter are compared to measurements made with an ultrasonic flow meter. Theoretical uncertainty analysis shows that the total uncertainty in flow rates from the virtual flow meter is 1.46% with 95% confidence; comparison of virtual flow meter results with measurements from an ultrasonic flow meter yielded anuncertainty of 1.46% with 99% confidence. The comparable results from the theoretical uncertainty analysis and empirical comparison with the ultrasonic flow meter corroborate each other, and tend to validate the approach to computationally estimating uncertainty for virtual sensors introduced in this study.

Song, Li; Wang, Gang; Brambley, Michael R.

2013-04-28T23:59:59.000Z

444

Systematic Errors in Measuring the Energy of Wet Steam with Dry-Steam Meters  

Science Journals Connector (OSTI)

Systematic errors are considered in measuring mass flow rate, specific enthalpy, thermal power, and energy for wet steam by means of meters intended for dry saturated steam.

E. G. Abarinov; K. S. Sarelo

2002-03-01T23:59:59.000Z

445

Experience in the Application of Single-Beam Ultrasonic Flow Meters for Turbines  

SciTech Connect (OSTI)

Experience in the use of ultrasonic flow meters at the Bratskaya and Vilyuiskaya HPP is described. The article is of interest to field engineers.

Krasilnikov, A. M.; Dmitriev, S. G. [Joint-Stock Company 'Research Institute for Power Constructions' (Russian Federation); Karyakin, V. A. [Zagorsk Hydroelectric Pumped Storage Power Plant (Russian Federation)

2002-03-15T23:59:59.000Z

446

Meter Damage: Many customers have questions about who is responsible for repair to the electrical service at their homes. These pages may help to answer  

E-Print Network [OSTI]

Meter Damage: Many customers have questions about who is responsible for repair. weather head stack meter base connectors house knob weather head connectors mast clamp stack meter base meter meter #12; Let's start with definitions: Meter base: This is the metal box mounted

Rose, Annkatrin

447

Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering  

E-Print Network [OSTI]

The Private and Public Economies of Renewable Electricityprivate sector, began to push for deregulation in the electricityprivate customer value of behind-the-meter PV generation, as potential customers most often will consider the value of avoided electricity

Darghouth, Naim Richard

2013-01-01T23:59:59.000Z

448

Analysis of interval-censored data with Weibull lifetime distribution  

E-Print Network [OSTI]

& OR Unit, Indian Statistical Institute, 203 B.T. Road, Kolkata, Pin 700108, India. Department of Mathematics and Statistics, Indian Institute of Technology Kanpur, Pin 208016, India. Corresponding author, e point. The event time is considered to be interval censored when an event occurs within some interval

Kundu, Debasis

449

Ash level meter for a fixed-bed coal gasifier  

DOE Patents [OSTI]

An ash level meter for a fixed-bed coal gasifier is provided which utilizes the known ash level temperature profile to monitor the ash bed level. A bed stirrer which travels up and down through the extent of the bed ash level is modified by installing thermocouples to measure the bed temperature as the stirrer travels through the stirring cycle. The temperature measurement signals are transmitted to an electronic signal process system by an FM/FM telemetry system. The processing system uses the temperature signals together with an analog stirrer position signal, taken from a position transducer disposed to measure the stirrer position to compute the vertical location of the ash zone upper boundary. The circuit determines the fraction of each total stirrer cycle time the stirrer-derived bed temperature is below a selected set point, multiplies this fraction by the average stirrer signal level, multiplies this result by an appropriate constant and adds another constant such that a 1 to 5 volt signal from the processor corresponds to a 0 to 30 inch span of the ash upper boundary level. Three individual counters in the processor store clock counts that are representative of: (1) the time the stirrer temperature is below the set point (500.degree. F.), (2) the time duration of the corresponding stirrer travel cycle, and (3) the corresponding average stirrer vertical position. The inputs to all three counters are disconnected during any period that the stirrer is stopped, eliminating corruption of the measurement by stirrer stoppage.

Fasching, George E. (Morgantown, WV)

1984-01-01T23:59:59.000Z

450

Flow meter evaluation for U.S. Navy Public Works Center, San Diego, California  

SciTech Connect (OSTI)

The U.S. Navy Public Works Center San Diego (PWCSD) was concerned about the accuracy of various flow meters on steam and compressed air lines serving Naval facilities in San Diego, California. The flow meters had experienced various inconsistencies that had not been resolved prior to July 1993. Pacific Northwest Laboratory, Richland, Washington, evaluated the operation of 10 out of 79 steam and compressed air flow meters at PWCSD. The evaluation was limited to analysis of historical information and review of existing operating procedures. On-site investigation of the flow meters was limited to external observations of the flow-sensing equipment and a check of the flow computer program. PNL did not remove installed sensing equipment (i.e., flow meters or temperature or pressure sensors) to evaluate existing condition or check calibration. Although many of the flow meter errors can be traced to improperly normalized readings and to meters improperly compensated for temperature and pressure, lack of regular maintenance, including proper calibration, was evidenced throughout this study. A strict calibration schedule should be established for all steam and air flow meters, including calibration of the temperature sensor, pressure sensor, and flow turbine. It is recommended that the most crucial flow meters (such as the 10 evaluated in this study) be calibrated yearly. The remaining 69 flow meters could be placed on a staggered, biyearly calibration schedule. Calibration should be done by qualified personnel only. Improper calibration is often worse than no calibration at all. An outside firm is recommended to be contracted with to perform all maintenance and calibration on flow meters at the Naval facilities. Use of an outside firm would better facilitate regular, reliable calibration while removing liability for damaged parts.

Chvala, W.D. Jr.; McMordie, K.L.; Szydlowski, R.F.

1995-06-01T23:59:59.000Z

451

Response of a slotted plate flow meter to horizontal two phase flow  

E-Print Network [OSTI]

meter is always better in performance and accuracy than the standard orifice plate flow meter. This study is primarily based on how a slotted plate responds to horizontal two-phase flow with air and water being used as the working fluids. The plates...

Muralidharan, Vasanth

2005-02-17T23:59:59.000Z

452

Unaccounted-for gas project. Measurement Task Force (orifice meter studies). Volume 2B. Final report  

SciTech Connect (OSTI)

The study was aimed at determining unaccounted-for (UAF) gas volumes resulting from operating Pacific Gas and Electric Co.'s transmission and distribution systems during 1987. Activities and methods are described and results are presented for research conducted on orifice meter accuracy. The Measurement Task Force determined that orifice metering inaccuracies were the largest single contributor to 1987 UAF.

Godkin, B.J.; Robertson, J.D.; Wlasenko, R.G.; Cowgill, R.M.; Grinstead, J.R.

1990-06-01T23:59:59.000Z

453

Quantum noise of non-ideal Sagnac speed meter interferometer with asymmetries  

E-Print Network [OSTI]

The speed meter concept has been identified as a technique that can potentially provide laser-interferometric measurements at a sensitivity level which surpasses the Standard Quantum Limit (SQL) over a broad frequency range. As with other sub-SQL measurement techniques, losses play a central role in speed meter interferometers and they ultimately determine the quantum noise limited sensitivity that can be achieved. So far in the literature, the quantum noise limited sensitivity has only been derived for lossless or lossy cases using certain approximations (for instance that the arm cavity round trip loss is small compared to the arm cavity mirror transmission). In this article we present a generalised, analytical treatment of losses in speed meters that allows accurate calculation of the quantum noise limited sensitivity of Sagnac speed meters with arm cavities. In addition, our analysis allows us to take into account potential imperfections in the interferometer such as an asymmetric beam splitter or differences of the reflectivities of the two arm cavity input mirrors. Finally,we use the examples of the proof-of-concept Sagnac speed meter currently under construction in Glasgow and a potential implementation of a Sagnac speed meter in the Einstein Telescope (ET) to illustrate how our findings affect Sagnac speed meters with meter- and kilometre-long baselines.

S. L. Danilishin; C. Graef; S. S. Leavey; J. Hennig; E. A. Houston; D. Pascucci; S. Steinlechner; J. Wright; S. Hild

2014-12-02T23:59:59.000Z

454

Trinity College Green Week 2012 Energy Competition Win a Domestic Energy Meter  

E-Print Network [OSTI]

Trinity College Green Week 2012 Energy Competition ­ Win a Domestic Energy Meter As part of College Green Week the "e3" programme and Director of Buildings Office is promoting an energy related would you like to win a domestic whole house energy meter as part of Trinity College Green Week 2012

O'Mahony, Donal E.

455

THE CONGESTION PIE: DELAY FROM COLLISIONS, POTENTIAL RAMP METERING GAIN, AND EXCESS DEMAND  

E-Print Network [OSTI]

THE CONGESTION PIE: DELAY FROM COLLISIONS, POTENTIAL RAMP METERING GAIN, AND EXCESS DEMAND the great potential to mitigate congestion by ramp metering. In addition to the three congestion pie slices in the division of the congestion `pie' into its constituent slices as in Figure 1. Knowledge of the congestion

Varaiya, Pravin

456

Performance Evaluation of Adaptive Ramp-Metering Algorithms Using Microscopic Traffic Simulation Model  

E-Print Network [OSTI]

to implementation on the target freeway network. In this paper, a capability-enhanced PARAMICS simulation model has evaluation; Simulation models; Algorithms. Introduction Ramp metering has been recognized as an effectivePerformance Evaluation of Adaptive Ramp-Metering Algorithms Using Microscopic Traffic Simulation

Levinson, David M.

457

Form EIA-930 HOURLY AND DAILY BALANCING AUTHORITY OPERATIONS REPORT  

U.S. Energy Information Administration (EIA) Indexed Site

930 930 HOURLY AND DAILY BALANCING AUTHORITY OPERATIONS REPORT INSTRUCTIONS Due Date: mm/dd/yyyy Approved: OMB No. 1905-0129 Approval Expires: 10/31/2016 Burden: 0.19 hours Page 1 Draft for Discussion only PURPOSE Form EIA-930 requires Internet posting of hourly balancing authority operating data. The posted data are used to monitor the current status and trends of the electric power industry, and to support enhancement of electric system operations. REQUIRED RESPONDENTS For the contiguous United States: all entities that are listed in NERC's Compliance Registry as a balancing authority must post balancing authority operating information required by this survey. Other than the Midwest ISO (MISO), registered balancing authorities that are parties

458

Hourly Energy Emission Factors for Electricity Generation in the United  

Open Energy Info (EERE)

Hourly Energy Emission Factors for Electricity Generation in the United Hourly Energy Emission Factors for Electricity Generation in the United States Dataset Summary Description Emissions from energy use in buildings are usually estimated on an annual basis using annual average multipliers. Using annual numbers provides a reasonable estimation of emissions, but it provides no indication of the temporal nature of the emissions. Therefore, there is no way of understanding the impact on emissions from load shifting and peak shaving technologies such as thermal energy storage, on-site renewable energy, and demand control. This project utilized GridViewTM, an electric grid dispatch software package, to estimate hourly emission factors for all of the eGRID subregions in the continental United States. These factors took into account electricity imports and exports

459

INCITE Program Doles Out Hours on Supercomputers | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

INCITE Program Doles Out Hours on Supercomputers INCITE Program Doles Out Hours on Supercomputers INCITE Program Doles Out Hours on Supercomputers November 5, 2012 - 1:30pm Addthis Mira, the 10-petaflop IBM Blue Gene/Q system at Argonne National Laboratory, is capable of carrying out 10 quadrillion calculations per second. Each year researchers apply to the INCITE program to get to use this machine's incredible computing power. | Photo courtesy of Argonne National Lab. Mira, the 10-petaflop IBM Blue Gene/Q system at Argonne National Laboratory, is capable of carrying out 10 quadrillion calculations per second. Each year researchers apply to the INCITE program to get to use this machine's incredible computing power. | Photo courtesy of Argonne National Lab. Charles Rousseaux Charles Rousseaux Senior Writer, Office of Science

460

Hanford Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Shipped  

Broader source: Energy.gov (indexed) [DOE]

Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Shipped Four Months Ahead of Schedule Hanford Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Shipped Four Months Ahead of Schedule June 2, 2011 - 12:00pm Addthis Media Contact Cameron Hardy, DOE (509) 376-5365 Cameron.Hardy@rl.doe.gov RICHLAND, WASH. - The U.S. Department of Energy (DOE) at Hanford surpassed a Tri-Party Agreement Milestone by four months in shipping 1,000 cubic meters of transuranic waste off the Hanford Site in route to the Waste Isolation Pilot Plant (WIPP) in New Mexico before September 30, 2011. The milestone for shipping waste was met in May 2011. Since the shipments began in 2000, 620 shipments have left the Hanford Site, a total of 4,137 cubic meters of transuranic waste. Milestones for

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Tips: Smart Meters and a Smarter Power Grid | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tips: Smart Meters and a Smarter Power Grid Tips: Smart Meters and a Smarter Power Grid Tips: Smart Meters and a Smarter Power Grid July 2, 2012 - 8:13pm Addthis The Smart Grid will consist of controls, computers, automation, and new technologies and equipment -- including a smart meter at your home -- working together to respond digitally to our quickly changing electric demand. The Smart Grid will consist of controls, computers, automation, and new technologies and equipment -- including a smart meter at your home -- working together to respond digitally to our quickly changing electric demand. What are the key facts? Like the Internet, the Smart Grid will consist of controls, computers, automation, and new technologies and equipment working together to respond digitally to our quickly changing electric demand.

462

Hydro-Québec Net Metering (Quebec, Canada) | Open Energy Information  

Open Energy Info (EERE)

Hydro-Québec Net Metering (Quebec, Canada) Hydro-Québec Net Metering (Quebec, Canada) No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Last modified on February 13, 2013. EZFeed Policy Place Quebec, Canada Applies to Utility Hydro-Quebec Name Hydro-Québec Net Metering (Quebec, Canada) Policy Type Net Metering Affected Technologies Geothermal Electric, Solar Photovoltaics Active Policy Yes Implementing Sector Utility Funding Source Hydro-Quebec Primary Website http://www.hydroquebec.com/self-generation/index.html Summary In line with Hydro-Québec's commitment to the environment and sustainable development, Hydro-Québec is supporting self-generation with a new rate offering: the net metering option. This option reflects a broad approach to

463

Demand Response and Smart Metering Policy Actions Since the Energy Policy  

Broader source: Energy.gov (indexed) [DOE]

and Smart Metering Policy Actions Since the Energy and Smart Metering Policy Actions Since the Energy Policy Act of 2005: A Summary for State Officials Demand Response and Smart Metering Policy Actions Since the Energy Policy Act of 2005: A Summary for State Officials This report represents a review of policy developments on demand response and other related areas such as smart meters and smart grid. It has been prepared by the Demand Response Coordinating Committ ee (DRCC) for the National Council on Electricity Policy (NCEP). The report focuses on State and Federal policy developments during the period from 2005 to mid-year 2008. It is an att empt to catalogue information on policy developments at both the federal and state level, both in the legislative and regulatory arenas. Demand Response and Smart Metering Policy Actions Since the Energy Policy

464

Hanford Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Shipped  

Broader source: Energy.gov (indexed) [DOE]

Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Shipped Four Months Ahead of Schedule Hanford Surpasses Transuranic Waste Milestone: 1,000 Cubic Meters Shipped Four Months Ahead of Schedule June 2, 2011 - 12:00pm Addthis Media Contact Cameron Hardy, DOE (509) 376-5365 Cameron.Hardy@rl.doe.gov RICHLAND, WASH. - The U.S. Department of Energy (DOE) at Hanford surpassed a Tri-Party Agreement Milestone by four months in shipping 1,000 cubic meters of transuranic waste off the Hanford Site in route to the Waste Isolation Pilot Plant (WIPP) in New Mexico before September 30, 2011. The milestone for shipping waste was met in May 2011. Since the shipments began in 2000, 620 shipments have left the Hanford Site, a total of 4,137 cubic meters of transuranic waste. Milestones for

465

Navy Estimated Average Hourly Load Profile by Month (in MW)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Navy Estimated Average Hourly Load Profile by Month (in MW) MONTH HE1 HE2 HE3 HE4 HE5 HE6 HE7 HE8 HE9 HE10 HE11 HE12 HE13 HE14 HE15 HE16 HE17 HE18 HE19 HE20 HE21 HE22 HE23 HE24...

466

BIOLOGY 650 (credit 2 hours) Animal Physiology LABORATORY  

E-Print Network [OSTI]

BIOLOGY 650 (credit 2 hours) Animal Physiology LABORATORY Spring 2011 Instructor: ROBIN COOPER , Ph role of ion channels and transporters in regulation of the membrane potential will be covered in great-neuron communication through electrical and chemical synapses will be examined in live preparations. The historical

Cooper, Robin L.

467

Aegis Combat and Weapon Systems Overview 24 hours, $1495  

E-Print Network [OSTI]

Aegis Combat and Weapon Systems Overview 24 hours, $1495 Launched from the Advanced Surface Missile that led to the initiation of Aegis. Topics Include: · AegisOverviewandHistory · AegisBMD · AegisWeaponSEprocessensuresthatsystemsaredevelopedtomeet affordable, operationally effective, and timely mission objectives. FocusonengineeringtheWeapon

Fork, Richard

468

BRASENOSE COLLEGE 8-HOUR STIPENDIARY LECTURERSHIP IN PHILOSOPHY  

E-Print Network [OSTI]

BRASENOSE COLLEGE OXFORD 8-HOUR STIPENDIARY LECTURERSHIP IN PHILOSOPHY FURTHER PARTICULARS in Philosophy at Brasenose College, Oxford. The post is tenable from 1 October 2013 (finishing date: 31st information about the College can be found at www.bnc.ox.ac.uk. Brasenose has a strong tradition in Philosophy

Oxford, University of

469

Folding Proteins at 500 ns/hour with Work Queue  

E-Print Network [OSTI]

in part to the unbiased nature of these simulations: the low-energy regions of the free-energy landscape to achieve an aggregate sampling rate of over 500 ns/hour. As a comparison, a single process typically are oversampled while the (arguably more interesting) high-energy tran- sition regions are rarely observed

Thain, Douglas

470

Credit Based; Intermediate Swimming Credit/Hours Class  

E-Print Network [OSTI]

Center Pool Course Description: Intermediate stroke and swimming skills Prerequisites: Must have by swimming laps during open swim/lap swim at MSU pool. Lap swim times are available online or at the frontCredit Based; Intermediate Swimming Credit/Hours Class Title Lead Instructor Phone Email Office

Maxwell, Bruce D.

471

Credit Based; Intermediate Swimming Credit/Hours Class  

E-Print Network [OSTI]

at the meet. 3) Swim laps during open swim/lap swim at MSU pool. A sheet will be posted on D2l that you. Emergency phone B. Pool Rules C key swimming skills 1. Breathing 2. Floating/body position 3. Treading waterCredit Based; Intermediate Swimming Credit/Hours Class Title Lead Instructor Phone Email Office

Maxwell, Bruce D.

472

Pay and Leave Administration and Hours of Duty  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The order establishes requirements and responsibilities for the management of pay, including overtime pay and compensatory time, leave administration, time and attendance reporting, and hours of duty. Cancels DOE O 322.1B and DOE O 535.1. Admin Chg 1, dated 5-10-12, cancels DOE O 322.1C.

2011-01-19T23:59:59.000Z

473

Experimental test results presented for field-damaged orifice meter plates  

SciTech Connect (OSTI)

Tests demonstrate that, unlike other types of meters, there is minimal loss of accuracy with orifice meters even when operational excursions are such that severe damage occurs. Both flange taps and pipe taps effectively have the same general pattern in that the actual coefficient increases with increasing permanent deformation. Of the two types of orifice tap, these data indicate that flange-tapped orifices may be less susceptible to severe deformation. This is probably caused by changes in the local pressure gradients in the vicinity of the plate. Since pipe taps are at such a large distance from the plate, these changes are probably not noticeable due to the turbulent mixing that takes place. With orifice meters, visual inspection of the plates after severe operation is recommended, to tell the user if the plate is beyond specifications. With other types of meters (i.e., other than differential meters) recalibration is the only method of determining if the meter has been affected. Where damage is apparent, the plate (or the meter if it is not of the differential type) should be immediately replaced.

Teyssandier, R.G.; Chisman, W.E.

1984-04-30T23:59:59.000Z

474

Instrument Qualification of Custom Fabricated Water Activity Meter for Hot Cell Use  

SciTech Connect (OSTI)

This report describes a custom fabricated water activity meter and the results of the qualification of this meter as described in the laboratory test plan LAB-PLN-11-00012, Testing and Validation of an Enhanced Acquisition and Control System. It was calibrated against several NaOH solutions of varying concentrations to quantify the accuracy and precision of the instrument at 20 C and 60 C. Also, a schematic and parts list of the equipment used to make the water activity meter will be presented in this report.

McCoskey, Jacob K.

2014-01-22T23:59:59.000Z

475

A model of the VU (volume-unit) meter, with speech applications Bryce E. Lobdell and Jont B. Allen  

E-Print Network [OSTI]

A model of the VU (volume-unit) meter, with speech applications Bryce E. Lobdell and Jont B. Allen October 2006; accepted 12 October 2006 The Volume-Unit VU meter, used in speech research prior. There are no known software implementations of this meter, which meet the 1954 ASA standard and provide

Allen, Jont

476

Monjolo: An Energy-Harvesting Energy Meter Architecture Samuel DeBruin, Bradford Campbell, and Prabal Dutta  

E-Print Network [OSTI]

Monjolo: An Energy-Harvesting Energy Meter Architecture Samuel DeBruin, Bradford Campbell 48109 {sdebruin,bradjc,prabal}@eecs.umich.edu ABSTRACT Conventional AC power meters perform at least two distinct func- tions: power conversion, to supply the meter itself, and energy me- tering, to measure

Dutta, Prabal

477

Electricit de France's study of the acoustic scintillation flow meter results in expanding its range and sensitivity  

E-Print Network [OSTI]

Electricité de France's study of the acoustic scintillation flow meter results in expanding its to study the Acoustic Scintillation Flow Meter (ASFM) developed by ASL AQFlow. The study was done for the next generation of acoustic scintillation flow meters. 1. Background For EDF's hydraulic power division

Paris-Sud XI, Université de

478

Traffic Equilibration: The Case of the Twin Cities Ramp Meter Shut Off David Levinson1and Atif Sheikh2  

E-Print Network [OSTI]

Traffic Equilibration: The Case of the Twin Cities Ramp Meter Shut Off David Levinson1and Atif Sheikh2 Abstract In Fall 2000, more than 430 ramp meters in the Twin Cities metropolitan area were shut down in order to evaluate the effectiveness of the metering system. This shutdown disturbed normal

Levinson, David M.

479

SDG&E Customers Can Connect Home Area Network Devices With Smart Meters |  

Open Energy Info (EERE)

SDG&E Customers Can Connect Home Area Network Devices With Smart Meters SDG&E Customers Can Connect Home Area Network Devices With Smart Meters Home > Groups > Utility Rate Graham7781's picture Submitted by Graham7781(2002) Super contributor 16 January, 2013 - 11:09 OpenEI San Diego Gas and Electric Smart Meters Smartgrid article reposted from Smartgrid.gov SAN DIEGO, Jan. 10, 2013 - San Diego Gas & Electric (SDG&E) customers can now purchase and install home area network devices to see how much energy they are using in near real-time and help identify high energy use appliances. With in-home energy display devices connected to their electric smart meters, SDG&E customers have access to a new tool to help them make smart energy consumption decisions to reduce their overall energy usage and costs. SDG&E has tested several new in-home energy display devices and customers

480

Development of 2-Meter Soil Temperature Probes and Results of Temperature  

Open Energy Info (EERE)

Development of 2-Meter Soil Temperature Probes and Results of Temperature Development of 2-Meter Soil Temperature Probes and Results of Temperature Survey Conducted at Desert Peak, Nevada, USA Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Development of 2-Meter Soil Temperature Probes and Results of Temperature Survey Conducted at Desert Peak, Nevada, USA Abstract Temperature gradient drilling has historically been a key tool in the exploration for geothermal resources in the Great Basin, USA but regulatory, environmental, and accessibility issues, as well as the expense of drilling, are increasingly limiting its use. In cases where thermal groundwater is not overlain by near-surface cold aquifers, temperatures measured at a depth of 2-meters is an efficient method for mapping thermal anomalies at a high level of detail. This is useful for augmenting deeper

Note: This page contains sample records for the topic "hourly interval meters" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Pantex installs new meters to help to reduce energy consumption | National  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

meters to help to reduce energy consumption | National meters to help to reduce energy consumption | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Pantex installs new meters to help to ... Pantex installs new meters to help to reduce energy consumption Posted By Office of Public Affairs Project Manager Janice Clark gives a safety briefing.

482

Tips: Smart Meters and a Smarter Power Grid | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Tips: Smart Meters and a Smarter Power Grid Tips: Smart Meters and a Smarter Power Grid July 2, 2012 - 8:13pm Addthis The Smart Grid will consist of controls, computers, automation, and new technologies and equipment -- including a smart meter at your home -- working together to respond digitally to our quickly changing electric demand. The Smart Grid will consist of controls, computers, automation, and new technologies and equipment -- including a smart meter at your home -- working together to respond digitally to our quickly changing electric demand. What are the key facts? Like the Internet, the Smart Grid will consist of controls, computers, automation, and new technologies and equipment working together to respond digitally to our quickly changing electric demand.

483

Pantex installs new meters to help to reduce energy consumption | National  

National Nuclear Security Administration (NNSA)

meters to help to reduce energy consumption | National meters to help to reduce energy consumption | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Pantex installs new meters to help to ... Pantex installs new meters to help to reduce energy consumption Posted By Office of Public Affairs Project Manager Janice Clark gives a safety briefing.

484

Use of Rapid Temperature Measurements at a 2-Meter Depth to Augment Deeper  

Open Energy Info (EERE)

Use of Rapid Temperature Measurements at a 2-Meter Depth to Augment Deeper Use of Rapid Temperature Measurements at a 2-Meter Depth to Augment Deeper Temperature Gradient Drilling Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Use of Rapid Temperature Measurements at a 2-Meter Depth to Augment Deeper Temperature Gradient Drilling Abstract Temperature gradient drilling has historically been a key tool in the exploration for geothermal resources in the Great Basin, USA, but regulatory, environmental, and accessibility issues, as well as the expense of drilling, are increasingly limiting its use. In cases where thermal groundwater is not overlain by near-surface cold aquifers, it is possible to augment temperature gradient drilling with temperatures measured from a 2-meter depth. We discuss the development of a rapid, efficient, and

485

Nissan and Centro partner to reduce energy cost 20% through improved metering  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Centro Inc. Nissan Centro Inc. Nissan 321 Hill Avenue 983 Nissan Drive Nashville, TN 37210 Smyrna, TN 37167 Business: Flow Control Distributor & Representative Business: Automobile Manufacturing Brad Davis Chris Goddard Territory Manager Environmental Engineer Phone: 615-255-2220 Phone: 615-459-1633 Email: bdavis@centromemphis.com Email: chris.goddard@nissan-usa.com Nissan and Centro partner to reduce energy cost 20% through improved metering Project Scope Nissan wanted to precisely measure consumption by department in their Smyrna facility. For low pressure natural gas applications, Nissan sought a simple, reliable metering device with no moving parts. Centro determined that the Aaliant Target Flow meter and the Fox Thermal Mass Flow meter would meet

486

The Intersection of Net Metering and Retail Choice: An Overview of Policy, Practice and Issues  

Broader source: Energy.gov [DOE]

In this report, the authors studied different facets of crediting mechanisms, and defined five different theoretical models describing different ways competitive suppliers and utilities provide net metering options for their customers. They then provided case studies to illustrate the models.

487

A Key Management Scheme for Secure Communications of Advanced Metering Infrastructure  

Science Journals Connector (OSTI)

Key management for secure communications of Advanced Metering Infrastructure is an unsolved problem until now. The ... proposing a key management scheme based on a hybrid-tree graph for AMI. The cyber security...

Jinshan Chen; Nian Liu; Wenxia Liu; Hong Luo

2011-01-01T23:59:59.000Z

488

Evaluation of a Close Coupled Slotted Orifice, Electrical Impedance, and Swirl Flow Meters for Multiphase Flow  

E-Print Network [OSTI]

homogenized flow for several pipe diameters downstream of the plate. This characteristic provides a homogeneous mixture at the inlet of the swirl meter, and impedance probe for gas volume fraction measurement (GVF). In order to evaluate the performance...

Cevik, Muhammet

2013-09-11T23:59:59.000Z

489

Too expensive to meter: the influence of transaction costs in transportation and communication  

Science Journals Connector (OSTI)

...the US Atomic Energy Commission, is...enjoy in their homes electrical energy too cheap to meter...of electricity consumption in the system...reduce electricity consumption or at least shift...the declining average (or per user...

2008-01-01T23:59:59.000Z

490

High Resolution Study of Micro-Meter Particle Detachment and Resuspension on Different Surfaces  

E-Print Network [OSTI]

In an effort to understand the resuspension phenomena, interactions of spherical micro-meter particles (glass beads (GB) and Stainless steel (SS)) were investigated experimentally on different surfaces (glass, ceramic, hardwood, metal and chemical...

Kassab, Asmaa 1983-

2012-08-16T23:59:59.000Z

491

Nissan North America: How Sub-Metering Changed the Way a Plant Does Business  

Broader source: Energy.gov [DOE]

This case study describes how Nissan North America uses sub-meters to measure a range of variables at its U.S. plants, including electricity and compressed air, and identify opportunities to reduce energy consumption.

492

The Impact of Rate Design and Net Metering on the Bill Savings from  

Open Energy Info (EERE)

Impact of Rate Design and Net Metering on the Bill Savings from Impact of Rate Design and Net Metering on the Bill Savings from Distributed Photovoltaics (PV) for Residential Customers in California Jump to: navigation, search Tool Summary LAUNCH TOOL Name: The Impact of Rate Design and Net Metering on the Bill Savings from Distributed Photovoltaics (PV) for Residential Customers in California Focus Area: Renewable Energy Topics: Best Practices Website: eetd.lbl.gov/ea/emp/reports/lbnl-3276e.pdf Equivalent URI: cleanenergysolutions.org/content/impact-rate-design-and-net-metering-b Language: English Policies: Deployment Programs DeploymentPrograms: Demonstration & Implementation This report analyzes the bill savings from photovoltaic (PV) deployment for residential customers of California's two largest electric utilities -

493

A field example of a gas orifice meter with debris-ridden liquid in mist flow  

SciTech Connect (OSTI)

A field example of debris-ridden liquids in an orifice meter is presented in this paper. Flow conditions in gas pipelines containing hydrocarbon liquids and particulate matter are discussed. Known effects on measurement of the presence of these materials in orifice meters is presented. By definition, gas measurement is accurate if performed on a clean and dry flow stream. This paper demonstrates the importance of removing as much liquid and debris as possible prior to measurement.

Chisholm, J.L.; Mooney, C.V. [Texas A and M Univ., Kingsville, TX (United States); Datta-Barua, L.; Feldmann, R.J.

1995-12-31T23:59:59.000Z

494

Metering and Monitoring Approaches for Verifying Energy Savings from Energy Conservation Retrofits: Experiences from the Field  

E-Print Network [OSTI]

METERING AND MONITORING APPROACHES FOR VERIFYING ENERGY SAVINGS FROM ENERGY CONSERVATION RETROFITS: EXPERIENCES FROM THE FIELD John R. McBride Charles J. Bohmer Roger H. Lippman Senior Scientist Senior Instrumentation Senior Instrumentation... drying process that operates at a constant energy level on a constant schedule are examples of this class of load. Engineering calculations without in-field metering and monitoring may be sufficient for this project class. Next in complexity...

McBride, J. R.; Bohmer, C. J.; Lippman, R. H.

495

The effects between two slotted plate flow meter under single, two, three components flow condition  

E-Print Network [OSTI]

THE INTERACTION BETWEEN A TWO SLOTTED PLATE FLOW METER UNDER ONE, TWO, OR THREE COMPONENT FLOW CONDITIONS A Thesis by SANG HYUN PARK Submitted to the Office of Graduate Studies of Texas A&M University in partial... fulfillment of the requirements for the degree of MASTER OF SCIENCE December 2004 Major Subject: Mechanical Engineering THE INTERACTION BETWEEN A TWO SLOTTED PLATE FLOW METER UNDER ONE, TWO, OR THREE COMPONENT FLOW...

Park, Sang Hyan

2005-02-17T23:59:59.000Z

496

Sub-metering to Electricity Use in Large-scale Commercial Buildings  

E-Print Network [OSTI]

;?#0;? Practice??Project example #0;?#0;? Use of data??Analysis Software Sub-metering and statistics to electricity use in commercial buildings 8 Method of sub-metering Whole electric power consumption of a building Hvac system Heating Circulating pump Oter... systems and equipments Equipments on Socket Special function room Electrically driven heating equipment Chiller Fan of cooling tower Chilled pump cooling pump Air hand unit Fresh air hand unit Fan coil unit Air conditioner Heating water system drinking...

Yuan, W.

2006-01-01T23:59:59.000Z

497

Evaluation of a slotted orifice plate flow meter using horizontal two phase flow  

E-Print Network [OSTI]

of MASTER OF SCIENCE December 2000 Major Subject: Mechanical Engineering EVALUATION OF A SLOTTED ORIFICE PLATE FLOW METER USING HORIZONTAL TWO PHASE FLOW A Thesis by ANITA ELENA FLORES Submitted to Texas A&M University in partial fulfillment...: Mechanical Engineering ABSTRACT Fvaluation of a Slotted Orifice Plate Flow Meter Using Horizontal Two Phase Flow. (December 2000) Anita Elena Flores, B. S. , Texas A&M I Jniversitv Chair of Advisory Committee: Dr. Herald L. Morrison In the past several...

Flores, Anita Elena

2012-06-07T23:59:59.000Z

498

Systematic mapping of Leaf Area Index across Canada using 250-meter MODIS data  

Science Journals Connector (OSTI)

An approach to generate a 250-meter Canada wide Leaf Area Index (LAI) map using 250-meter MODIS data is described. The full processing chain is introduced. The approach is based on intercalibration of Landsat and MODIS vegetation indices (VI's) combined with LAIVI's empirical relationships. Preliminary validation over two sites where field work was carried out shows promising results. Intercalibration of MODIS VI's before deriving LAI maps provides up to 65% improvement of the LAI overall accuracy.

Nadia Rochdi; Richard Fernandes

2010-01-01T23:59:59.000Z

499

Phase Structure of Gauge Theories on an Interval  

E-Print Network [OSTI]

We discuss gauge symmetry breaking in a general framework of gauge theories on an interval. We first derive a possible set of boundary conditions for a scalar field, which are compatible with several consistency requirements. It is shown that with these boundary conditions the scalar field can acquire a nontrivial vacuum expectation value even if the scalar mass square is positive. Any nonvanishing vacuum expectation value cannot be a constant but, in general, depends on the extra dimensional coordinate of the interval. The phase diagram of broken/unbroken gauge symmetry possesses a rich structure in the parameter space of the length of the interval, the scalar mass and the boundary conditions. We also discuss 4d chiral fermions and fermion mass hierarchies in our gauge symmetry breaking scenario.

Fujimoto, Yukihiro; Ohya, Satoshi; Sakamoto, Makoto

2011-01-01T23:59:59.000Z

500

Phase Structure of Gauge Theories on an Interval  

E-Print Network [OSTI]

We discuss gauge symmetry breaking in a general framework of gauge theories on an interval. We first derive a possible set of boundary conditions for a scalar field, which are compatible with several consistency requirements. It is shown that with these boundary conditions the scalar field can acquire a nontrivial vacuum expectation value even if the scalar mass square is positive. Any nonvanishing vacuum expectation value cannot be a constant but, in general, depends on the extra dimensional coordinate of the interval. The phase diagram of broken/unbroken gauge symmetry possesses a rich structure in the parameter space of the length of the interval, the scalar mass and the boundary conditions. We also discuss 4d chiral fermions and fermion mass hierarchies in our gauge symmetry breaking scenario.

Yukihiro Fujimoto; Tomoaki Nagasawa; Satoshi Ohya; Makoto Sakamoto

2011-08-09T23:59:59.000Z