Buildings Energy Data Book: 3.10 Hotels/Motels  

Buildings Energy Data Book (EERE)

1 2003 Floorspace and Energy Consumption for Hotels and MotelsInns (1) Hotels MotelsInns Average Electricity Consumption(kBtusSF): 61.3 40.5 Average Natural Gas...

2

Hotel/motel energy use strategies  

SciTech Connect

A monitoring program for Hotel/Motel energy use in three areas-space heating, space cooling, and domestic hot water systems is reported on. In space heating, thermostats were poorly maintained, base loads were unacceptably high. Waste in space cooling could be reduced by use of economizer systems such as the strainer cycle, indoor-outdoor control, and flywheel storage. Recirculating loops, which provide instantaneous hot water to rooms, might be turned off during non-peak hours. Incoming city main well temperatures can be used to preheat water. The survey found little concern for energy conservation in the commercial areas of hotels. For example, at 2 a.m. all the lights were on in an empty ballroom. Many kitchen appliances were left running. In kitchens the heat booster in dishwashers is left on when the machine is off. The habit of turning on all appliances when the kitchen opens is wasteful. Several other examples are given. Management of hotels must be shown, then, that they are sitting on top of a prime cost center of potential savings.

Smith, A.M.

1982-06-01T23:59:59.000Z

3

ENERGY STAR Building Upgrade Manual Chapter 12: Hotels and Motels...  

NLE Websites -- All DOE Office Websites (Extended Search)

care resources Small business resources State and local government resources ENERGY STAR Building Upgrade Manual Chapter 12: Hotels and Motels The Building Upgrade Manual is...

4

Energy Star Building Upgrade Manual Facility Type: Hotels and Motels Chapter 12  

NLE Websites -- All DOE Office Websites (Extended Search)

2. Facility Type: 2. Facility Type: Hotels and Motels Revised December 2007 12.1 Challenges and Opportunities 2 12.2 Energy-Use Profile 3 12.3 Technical Recommendations 4 Retrocommissioning 5 Lighting 8 Load Reduction 11 Air Distribution Systems 13 Heating and Cooling Systems 15 12.4 Financial and Implementation Issues 16 Bibliography 17 Glossary G-1 ENERGY STAR ® Building Manual 2 12. Facility Type: Hotels and Motels 12.1 Challenges and Opportunities The United States' 47,000 hotels and motels spend an average of $2,196 per available room each year on energy, an amount that represents about 6 percent of all hotel operating costs. The varied nature of the physical facilities and the activities that they host can make energy management especially challenging, whether the facility is a large convention hotel, part of

5

Summary report of energy usage/consumption analysis for six hotels/motels  

SciTech Connect

An analysis of energy consumption and energy use profiles for six hotels and motels of various types (transient, convention, resort) located in different geographical areas of the United States is summarized. Data include information collected at the six demonstration sites only during the heating and cooling seasons. Data show where the energy is used, how much is used and when it is used. A brief examination of strategies for reducing energy consumption is also included. Major hotel/motel functions are identified as: guest rooms, public areas, kitchens, dining areas, laundries, pools, elevators, and others. Energy use categories examined are: space heating, space cooling, domestic water heating, cooking, laundry dryers, lighting, HVAC auxiliaries, elevators, and others. The six hotels/motels are located in Vermont, Minnesota, Arizona, Georgia, and two in Texas. The building configuration, facilities, energy-using systems, and climatic conditions are described for each site. (LEW)

1981-12-01T23:59:59.000Z

6

ENERGY STAR Building Upgrade Manual Chapter 12: Hotels and Motels | ENERGY  

NLE Websites -- All DOE Office Websites (Extended Search)

12: Hotels and Motels 12: Hotels and Motels Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In This Section Campaigns Commercial building design Communications resources Energy management guidance Financial resources Portfolio Manager Products and purchasing Recognition Research and reports Service and product provider (SPP) resources Success stories Target Finder Technical documentation

7

Glossary G-1 ENERGY STAR ® Building Manual 1 12. Facility Type: Hotels and Motels  

E-Print Network (OSTI)

The United States ’ 47,000 hotels and motels spend an average of $2,196 per available room each year on energy, an amount that represents about 6 percent of all hotel operating costs. The varied nature of the physical facilities and the activities that they host can make energy management especially challenging, whether the facility is a large convention hotel, part of a large national chain, or a small inn or motel. However, the opportunities for improved guest comfort, longer equipment life, lower operating costs, and an improved corporate image make pursing energy efficiency worthwhile. ENERGY STAR partners in the lodging industry have greatly reduced their expenditures on energy through measures such as lighting upgrades in guest rooms, lobbies, and hallways; occupancy-based guest-room energy controls; and the installation of energy-efficient water heating equipment, while still providing benefits for hotel guests, owners, operators, and shareholders. Hotels and motels operate 24 hours a day, hosting guests and offering various services and amenities. Guest rooms, public lobbies, banquet facilities and restaurants, lounges, offices, retail outlets, and swimming pools fill the building or multiple buildings. Ice machines, vending machines, and game rooms may be scattered throughout. Laundries and kitchens are typically

unknown authors

2007-01-01T23:59:59.000Z

8

STATE OF CALIFORNIA HOTEL / MOTEL TRANSIENT OCCUPANCY TAX WAIVER  

E-Print Network (OSTI)

FOR STATE AGENCIES) HOTEL MOTEL OPERATORS: RETAIN THIS WAIVER FOR YOUR FILES TO SUBSTANTIATE YOUR REPORTS of the State Agency indicated below; that the charge for the occupancy at the above establishment on the dates of California. $ OCCUPANCY DATES AMOUNT PAID California State University, Fullerton STATE AGENCY NAME 800 North

de Lijser, Peter

9

Experience on design and operation of hotel/motel solar hot water systems  

SciTech Connect

The use of solar energy to preheat domestic hot water in hotels and motels has many advantages. Year long use of these solar systems provides shorter payback periods. Temperature requirements for hotel/motel use are relatively low and are compatible with low cost flat plate collectors. Simple controls relate to higher reliability in both drain-down and heat exchanger configurations. Solar systems are easily retrofitted to most existing hotel/motel hot water systems and there are many hotels and motels across the country with roof area sufficient in size to hold the required collector arrays. Hotel/motel systems with payback periods of less than four years, which provide 70% of the total hot water load, are discussed.

Brohl, E.C.; Struss, R.G.; Sidles, P.H.

1978-01-01T23:59:59.000Z

10

Buildings Energy Data Book: 3.10 Hotels/Motels  

Buildings Energy Data Book (EERE)

2 2 Lodging Industy, Sales and Occupancy Rates Year Sales ($2010 billion) Avg. Occupancy Rate Avg. Room Rate ($2010) 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 Note(s): Source(s): 1) Based on properties with 15 or more rooms The American Hotel & Lodging Association, 2002 Lodging Industy Profile, p. 2-3; The American Hotel & Lodging Association, 2003 Lodging Industy Profile, p. 2-3, 2002; The American Hotel & Lodging Association, 2004 Lodging Industy Profile, p. 2-4, 2004; The American Hotel & Lodging Association, 2005 Lodging Industy Profile, p. 2-4, 2005; The American Hotel & Lodging Association, 2006 Lodging Industy Profile, p. 2-4, 2006; The American Hotel & Lodging Association, 2007 Lodging Industy Profile, p. 2-4, 2007; The American Hotel & Lodging Association, 2008 Lodging Industry Profile p. 2-4, 2008; The American

11

Home Hotel and Motel Pool & Spa Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Home Hotel and Motel Pool & Spa Low Temperature Geothermal Facility Home Hotel and Motel Pool & Spa Low Temperature Geothermal Facility Jump to: navigation, search Name Home Hotel and Motel Pool & Spa Low Temperature Geothermal Facility Facility Home Hotel and Motel Sector Geothermal energy Type Pool and Spa Location Lava Hot Springs, Idaho Coordinates 42.6193625°, -112.0110712° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

12

Forecasting Uncertain Hotel Room Demand  

E-Print Network (OSTI)

Economic systems are characterized by increasing uncertainty in their dynamics. This increasing uncertainty is likely to incur bad decisions that can be costly in financial terms. This makes forecasting of uncertain economic variables an instrumental activity in any organization. This paper takes the hotel industry as a practical application of forecasting using the Holt-Winters method. The problem here is to forecast the uncertain demand for rooms at a hotel for each arrival day. Forecasting is part of hotel revenue management system whose objective is to maximize the revenue by making decisions regarding when to make rooms available for customers and at what price. The forecast approach discussed in this paper is based on quantitative models and does not incorporate management expertise. Even though, forecast results are found to be satisfactory for certain days, this is not the case for other arrival days. It is believed that human judgment is important when dealing with ...

Mihir Rajopadhye Mounir; Mounir Ben Ghaliay; Paul P. Wang; Timothy Baker; Craig V. Eister

2001-01-01T23:59:59.000Z

13

Texas energy conservation program: existing commercial, hotels and motels. [Workshop material  

SciTech Connect

This publication describes some simple methods by which the owner, manager, or operator of a hotel or motel can analyze its energy uses, determine the areas in which energy savings can be made, and estimate the magnitude of the cost savings in accordance with federal Department of Energy Procedures. The workbook is designed to provide a do-it-yourself fill-in-the-blanks approach to an energy-conservation program and is intended for use in small to medium hotels and motels which do not have full-time engineering personnel. The main energy-intensive functions of a hotel and some of the frequently observed areas of energy waste are emphasized, but it is recognized that each building will have its unique energy-use patterns that must be learned by the owner, manager, or operator or their designated energy coordinator and an energy-management committee. Specific measures are provided for restaurants and coffee shops. A pamphlet on Duo-Aire, the self-contained supply and exhaust air cooking ventilation system, is included.

1978-01-01T23:59:59.000Z

14

Buildings Energy Data Book: 3.10 Hotels/Motels  

Buildings Energy Data Book (EERE)

5 5 Energy Benchmarks for Newly Constructed Large Hotels, by Selected City and End-Use (thousand Btu per square foot) Miami 1A Houston 2A Phoenix 2B Atlanta 3A Los Angeles 3B Las Vegas 3B San Francisco 3C Baltimore 4A Albuquerque 4B Seattle 4C Chicago 5A Boulder 5B Minneapolis 6A Helena 6B Duluth 7 Fairbanks 8 Note(s): Source(s): 60.9 13.2 76.3 8.4 Commercial building energy benchmarks are based off of the current stock of commercial buildings and reflect 2004 ASHRAE 90.1 Climate Zones. They are designed to provide a consistent baseline to compare building performance in energy-use simulations.The benchmark building had 122,075 square feet and 6 floors. Benchmark interior lighting energy = 11.28 thousand Btu/SF. Interior equipment energy consumption = 24.77 thousand Btu/SF. DOE/EERE/BT, Commercial Building Benchmark Models, Version 1.3_5.0, Nov. 2010, accessed January 2012 at

15

Buildings Energy Data Book: 3.10 Hotels/Motels  

Buildings Energy Data Book (EERE)

6 6 Energy Benchmarks for Newly Constructed Small Hotels, by Selected City and End-Use (thousand Btu per square foot) Miami 1A Houston 2A Phoenix 2B Atlanta 3A Los Angeles 3B Las Vegas 3B San Francisco 3C Baltimore 4A Albuquerque 4B Seattle 4C Chicago 5A Boulder 5B Minneapolis 6A Helena 6B Duluth 7 Fairbanks 8 Note(s): Source(s): 36.6 2.7 12.0 3.9 Commercial building energy benchmarks are based off of the current stock of commercial buildings and reflect 2004 ASHRAE 90.1 Climate Zones. They are designed to provide a consistent baseline to compare building performance in energy-use simulations.The benchmark building had 43,186 square feet and 4 floors. Benchmark interior lighting energy = 13.79 thousand Btu/SF. Interior equipment energy consumption = 21.98 thousand Btu/SF. DOE/EERE/BT, Commercial Building Benchmark Models, Version 1.3_5.0, Nov. 2010, accessed January 2012 at

16

Buildings Energy Data Book: 3.10 Hotels/Motels  

Buildings Energy Data Book (EERE)

3 3 Lodging Industry Profile (Thousands) 2004 2006 2008 2010 Location Properties Rooms Properties Rooms Properties Rooms Properties Rooms Suburban Highway Urban Airport Resort Small Metro Rate Under $30 $30-44.99 $45-59.99 $60-85 Over $85 Number of Rooms Under 75 75 - 149 150 - 299 300 - 500 Over 500 Source(s): 17.5 1,746 6.7 446 6.8 452 7.1 480 7.3 498 15.8 1,564 15.9 1,577 16.8 1,668 4.9 754 1.9 274 2.0 275 2.1 294 2.2 305 4.6 706 4.5 691 4.7 721 3.8 595 14.5 826 14.4 827 15.1 878 15.4 904 4.1 595 3.6 567 3.7 584 0.8 54 8.0 510 7.1 435 7.3 418 6.6 406 0.9 56 0.9 58 1.2 54 14.5 896 14.3 1,368 14.2 1295 14.5 1326 15.8 1386 16.1 1,045 14.8 933 15.0 916 13.4 2060 27.5 1,164 26.9 1147 27.8 1188 28.1 1212 8.3 1,434 10.1 1668 11.4 1913 16.9 1773 4.2 847 4.1 824 4.3 853 4.4 876 14.3 1,524 14.5 1542 15.8 1668 The American Lodging Association, 2007 Lodging Industy Profile, p. 2-4, 2007; The American Lodging Association, 2008 Lodging Industry Profile p. 2-4,

17

Evaluation of economics of hotel/motel solar hot water projects  

SciTech Connect

Experience gained by the Ames Laboratory in managing projects in the Solar Hotel/Motel Hot Water initiative is used to evaluate economic factors. The analysis studies costs and trends from a limited number of projects. Initial analysis, based on cost data presented in the project proposals, shows that cost estimates vary widely for various reasons. Further analysis, based on incurred costs as projects are completed, is a continuing process. These actual costs are normalized to the extent possible to provide consistent comparisons between the systems of various projects. Correlations between proposed costs and actual costs are made to assist future evaluation of similar projects. Several projects, which were offered a grant to participate in these Hotel/Motel demonstrations, have declined to accept the grant on economic grounds. Economic analysis of these projects provides rationale for the apparent cost ineffectiveness. Systems now in operation have provided fuel cost savings data which are presented to show system payback periods. Finally, results of economic analysis of these projects are presented together with initial conclusions regarding cost-effective solar hot water system design.

Struss, R.G.; Brohl, E.C.; Sidles, P.H.

1978-01-01T23:59:59.000Z

18

HOTELS  

NLE Websites -- All DOE Office Websites (Extended Search)

U U Ur rb ba an n A At tm mo os sp ph he er ri ic c O Ob bs se er rv va at to or ry y ( ( U UA AO O) ) F F i ir rs st t P Pl la an nn ni in ng g W Wo or rk ks sh ho op p A Ag ge en nd da a 27-28 January, 2003 HOTELS Please Note: This list is not all-inclusive, but compiled to provide some suggestions. Occupancy at the Government rate is based on availability. The rates vary depending on the time of year, day of the week, number of nights. There are also special rates and packages available at different times of the year. Some hotels offer weekend rates. For an extended list click on this link and search NY: http://www.hotels.com EML is located on the West Side of Manhattan - "lower Manhattan" - Greenwich Village/SoHo area. The following hotels are on the West Side of Manhattan. EML can be reached by subway or taxi. Hotels

19

A room with a viewpoint: Using social norms to motivate environmental conservation in hotels  

E-Print Network (OSTI)

Two field experiments examined the effectiveness of signs requesting hotel guests’ participation in an environmental conservation program. Appeals employing descriptive norms (e.g., “the majority of guests reuse their towels”) proved superior to a traditional appeal widely used by hotels that focused solely on environmental protection. Moreover, normative appeals were most effective when describing group behavior that occurred in the setting that most closely matched individuals’ immediate situational circumstances (e.g., “the majority of guests in this room reuse their towels”), which we refer to as provincial norms. Theoretical and practical implications for managing proenvironmental efforts are discussed. Until recently, the greatest towel-related dilemma travelers faced was reflected in the old joke told by the nightclub comic, Henny Youngman, about the hotel where he had stayed the previous night: “What a hotel: the towels were so big and fluffy that I could hardly close my suitcase.” In recent years, however, the question of whether or not to remove hotel towels has been supplanted by the question of whether or not to reuse hotel towels during the course of one’s stay. With the adoption of environmental programs by hotels, more and more travelers are finding themselves urged to reuse their towels to help conserve environmental resources by saving energy and reducing the amount of detergent-related pollutants released into the environment. *Noah J. Goldstein is assistant professor of behavioral sciences at the

Noah J. Goldstein; Robert B. Cialdini

2008-01-01T23:59:59.000Z

20

Valance heating/cooling system attains largest application in 1,000-room hotel  

SciTech Connect

Room temperatures in the 1,000 guest rooms of Chicago's Hyatt Regency Hotel are controlled by a valance heating and cooling system that functions by means of radiation and convection. The valances are mounted below the ceiling and consists of finned tubes and a drain tube contained within a wall-mounted enclosure. The finned tubes and drain are connected to a riser system, that is connected to a hot and cold water supply. The economics of the system is discussed and with no fans, motors, or blowers to run, energy is conserved. (MCW)

1976-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Occupancy sensors for HVAC gaining in hotel industry  

SciTech Connect

The hotel industry is overcoming its skepticism as occupancy sensors with built-in thermistors to control heating, ventilating, and air conditioning (HVAC) units demonstrate their ability to cut energy costs as much as 30%. Despite the successful demonstrations and acceptance by Holiday Inn, some hotel managers of other chains continue to resist. Occupancy sensors have either ultrasonic or infrared signals, but differ from lighting control devices by also having internal thermistors and remote door switches. This allows the rooms to reach comfort levels only when the guest is present since occupants are only minimally affected if temperatures are modified during unoccupied periods. The system works best for roadside-type motels rather than convention hotels, where occupants are in and out of their rooms.

Ladd, C.

1985-12-02T23:59:59.000Z

22

SRI2013 | Hotel Accommodations  

Science Conference Proceedings (OSTI)

... blocks of rooms in two local hotels: ... DC North/Gaithersburg hotel (apparently booked up). ... Cornell High Energy Synchrotron Source; Canadian Light ...

23

Berkeley Hotels  

NLE Websites -- All DOE Office Websites (Extended Search)

Conference Hotel Block Room Reservation Information Conference Hotel Block Room Reservation Information If you plan to attend the SNAP Collaboration Meeting (June 1-3, 2006) and require lodging, please make your hotel reservations as soon as possible. We have block room reservations at these two hotels: 1) Doubletree Berkeley Marina Hotel (block of rooms reserved until May 10, 2006) 2) Hotel Durant (block of rooms reserved until May 1, 2006) Doubletree Berkeley Marina (three star hotel). Government Rates are: $100 (Single), $100 (Double), $110 (Triple), $120(Quad). Block room reservation for 30 rooms are for May 31 through June 3 (check-out), and is valid through Wednesday, May 10, 2006. To make a reservation: Please call the hotel (510-548-7920) by May 10th to make your reservations. To obtain the government rate, please let them know that you are with the "SNAP" group or the three letter code, "SNA". You will then need to give them your credit card information to make the reservation.

24

Initial Study of Solar Control Film in a Hotel Guest Room in Winter  

E-Print Network (OSTI)

In recent years, energy-efficient facilities have prevailed in the Hong Kong and China markets. Many of these facilities claim to generate considerable energy and money savings. Hoteliers, however, find that there is a lack of independent and local studies about energy performance and its related financial savings and environmental improvement brought by those facilities, such as heat pumps, solar-control film on the window, sensor and dimmer for lighting control, etc. Nevertheless, there is a lack of reliable and independent data about the energy performance and economic viability of the solar-control film applied in a real environment. In many situations, consumers are only given the laboratory's result of this energy saving facility. Research was carried out in summer to estimate its positive effect on energy saving. There is also a paucity of experiments conducted in winter to show its negative effect in cold weather. This study carries out an experiment in hotel guest rooms in winter in order to estimate the energy and lighting performance of solar-control film in winter. This experiment was conducted when the illuminance under 1000lux, the average visible light transmittance for the film was 49.8%, and with very low solar radiation being transmitted into indoor environment. Under these situations, the study found that the effect of solar energy passing through the film coating in the guest room can be neglected. Instead, the film can act as a layer to prevent heat to transmit to the outdoors, just like the greenhouse effect.

Chan, W. C.; Chen, Y.; Mak, B.; Li, D.; Huang, Y.; Xie, H.; Hou, G.

2006-01-01T23:59:59.000Z

25

Local Hotels/Motels - Gaithersburg, MD  

Science Conference Proceedings (OSTI)

... relationship with NIST. We provide this information as a convenience to NIST visitors and conference attendees. NIST does ...

2013-07-25T23:59:59.000Z

26

Sheraton Seattle Hotel Floor Plans  

Science Conference Proceedings (OSTI)

139th Annual Meeting & Exhibition. Sheraton Seattle Hotel Floor Plans. MEETING ROOMS. RESTROOMS. LEVEL 1. LEVEL. MEETING INFORMATION.

27

Evaluate hotel energy performance using data envelopment analysis.  

E-Print Network (OSTI)

???There are many factors affecting the hotel energy consumption, such as hotel classifications, floor area, numbers of guest rooms, nos. of room guests, mix of… (more)

Wan, Chun-wah.

2012-01-01T23:59:59.000Z

28

Sheraton Seattle Hotel Floor Plans - TMS  

Science Conference Proceedings (OSTI)

LEARN • NETWORK • ADVANCE. Sheraton Seattle Hotel Floor Plans. MEETING ROOMS. RESTROOMS. LEVEL. PIKE ST. TOWER. UNION ST. TOWER.

29

Solid-State Lighting: Hotel Information  

NLE Websites -- All DOE Office Websites (Extended Search)

Hotel Information to someone by Hotel Information to someone by E-mail Share Solid-State Lighting: Hotel Information on Facebook Tweet about Solid-State Lighting: Hotel Information on Twitter Bookmark Solid-State Lighting: Hotel Information on Google Bookmark Solid-State Lighting: Hotel Information on Delicious Rank Solid-State Lighting: Hotel Information on Digg Find More places to share Solid-State Lighting: Hotel Information on AddThis.com... Conferences & Meetings Past Conferences Presentations Publications Webcasts Videos Tools Hotel Information Hilton Tampa Downtown 211 N. Tampa St. Tampa, FL 33602 A block of hotel rooms has been reserved at the Hilton Tampa at a special rate for DOE workshop attendees. The rate for a standard room is $116 per night from January 25-February 1. The room block has been extended until noon ET on Friday, January 17,

30

Apparatus for conserving energy in a building. [Patent equipment for controlling energy use in unoccupied hotel rooms and other buildings  

SciTech Connect

Apparatus for turning off power-consuming appliances in rooms of a building having a private automatic branch exchange telephone system includes computer-controlled means at the exchange central periodically to apply short bursts of audio-frequency oscillations to telephone lines going to rooms in which power can be conserved. Detecting means in each room connected to the room telephone line provide an output on receipt of a burst which operates a line relay in the room, disconnecting power from the appliance in the room, for a predetermined time period greater than the time period between the periodic application of bursts at the exchange central.

James, E.C.; Fairfax, G.H.

1977-05-03T23:59:59.000Z

31

Solid-State Lighting: Hotel Information  

NLE Websites -- All DOE Office Websites (Extended Search)

Program » Solid-State Lighting » Program » Solid-State Lighting » Information Resources Printable Version Share this resource Send a link to Solid-State Lighting: Hotel Information to someone by E-mail Share Solid-State Lighting: Hotel Information on Facebook Tweet about Solid-State Lighting: Hotel Information on Twitter Bookmark Solid-State Lighting: Hotel Information on Google Bookmark Solid-State Lighting: Hotel Information on Delicious Rank Solid-State Lighting: Hotel Information on Digg Find More places to share Solid-State Lighting: Hotel Information on AddThis.com... Home Conferences & Meetings Past Conferences Presentations Publications Webcasts Videos Hotel Information Wyndham Grand Pittsburgh, 600 Commonwealth Place, Pittsburgh, PA 15222 The Wyndham Grand Pittsburgh room block has expired; however,

32

Enegiutredning Hotell Princess.  

E-Print Network (OSTI)

?? This report will show the energy usage of Hotel Princess in Sandviken, Sweden. When the hotel changed owner an examination of the hotels heating,… (more)

Ros, Henrik

2012-01-01T23:59:59.000Z

33

hotels.PDF  

NLE Websites -- All DOE Office Websites (Extended Search)

Some Berkeley Hotels 1 4 2 3 5 1. Hotel Shattuck Plaza, 2086 Allston Way 510845-7300 2. Hotel Durant, 2600 Durant Ave. 510845-8981 3. Bancroft Club Hotel, 2680 Bancroft Way 510...

34

In order to take advantage of these rates, please book directly with the hotel via email, phone or fax  

E-Print Network (OSTI)

VENUE 2 STAR HOTELS Hotel Balbi ** Via Balbi 21/3 ­ tel +39 010 2759288 ­ fax +39 010 252362 website www quadruple room 105 breakfast included Hotel della Posta ** Via Balbi 24 ­ tel +39 010 252929 ­ fax +39 010 from 70 triple room from 85 breakfast included Hotel Acquaverde ** Via Balbi 29 ­ tel +39 010 265427

Genova, Università degli Studi di

35

Shoshone Motel & Trailer Park Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

Shoshone Motel & Trailer Park Space Heating Low Temperature Geothermal Shoshone Motel & Trailer Park Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Shoshone Motel & Trailer Park Space Heating Low Temperature Geothermal Facility Facility Shoshone Motel & Trailer Park Sector Geothermal energy Type Space Heating Location Death Valley, California Coordinates Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

36

Wiesbaden Motel & Health Resort Space Heating Low Temperature Geothermal  

Open Energy Info (EERE)

Wiesbaden Motel & Health Resort Space Heating Low Temperature Geothermal Wiesbaden Motel & Health Resort Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Wiesbaden Motel & Health Resort Space Heating Low Temperature Geothermal Facility Facility Wiesbaden Motel & Health Resort Sector Geothermal energy Type Space Heating Location Ouray, Colorado Coordinates 38.0227716°, -107.6714487° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

37

Box Canyon Motel Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Motel Space Heating Low Temperature Geothermal Facility Motel Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Box Canyon Motel Space Heating Low Temperature Geothermal Facility Facility Box Canyon Motel Sector Geothermal energy Type Space Heating Location Ouray, Colorado Coordinates 38.0227716°, -107.6714487° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

38

Twin Peaks Motel Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Peaks Motel Space Heating Low Temperature Geothermal Facility Peaks Motel Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Twin Peaks Motel Space Heating Low Temperature Geothermal Facility Facility Twin Peaks Motel Sector Geothermal energy Type Space Heating Location Ouray, Colorado Coordinates 38.0227716°, -107.6714487° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

39

IntegratedEnergySysteminHotel (GasTechnologyInstitute)  

E-Print Network (OSTI)

A experimental area, using beams from the present GSI accelerator complex (energy range: 500 to 10 Me a contingent of rooms is available at the IBIS hotel in Darmstadt. The room rate is 71.00 per person and night, breakfast included. This arrangement will be valid latest until October 19. Please contact the hotel

Oak Ridge National Laboratory

40

Energy saving thermostat  

SciTech Connect

A thermostat device is disclosed for motels/hotels requiring the guest to use a key to select a desired room temperature which in turn requires that the thermostat must be set back to a preset temperature when guest desires to lock the door to his motel/hotel room upon leaving the room.

Fodera, A.W.

1983-09-13T23:59:59.000Z

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

ENERGY STAR Score for Hotels  

NLE Websites -- All DOE Office Websites (Extended Search)

Hotels in the United States Page 1 ENERGY STAR Score for Hotels in the United States Technical Reference OVERVIEW The ENERGY STAR Score for Hotels applies to properties renting...

42

SRO : single room occupancy  

E-Print Network (OSTI)

During August of 1996, I stayed in a series of SRO hotels in New York City leaving a book and diary behind when I checked out of each room. The books that were left in the rooms differ from one room to the other but all ...

Shimada, Taketo

1997-01-01T23:59:59.000Z

43

Airport, Transport & Hotel Information | ORNL  

NLE Websites -- All DOE Office Websites (Extended Search)

Departures - Live departure schedule Airlines - Links to individual airlines' websites Car Rental Flight Schedules Hotels - Area hotels Parking - Rates and suggestions Taxi -...

44

Oak Ridge Hotels | ornl.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Conferences Highlights Success Stories Contact Us Index Home | ORNL | Visiting ORNL SHARE Oak Ridge Hotels Contact information for local hotels is listed below. At ORNL Hotel...

45

Solid-State Lighting: Hotel Information  

NLE Websites -- All DOE Office Websites (Extended Search)

Hotel Information on Twitter Bookmark Solid-State Lighting: Hotel Information on Google Bookmark Solid-State Lighting: Hotel Information on Delicious Rank Solid-State...

46

Cogeneration for resort hotels  

Science Conference Proceedings (OSTI)

Resort Hotels should be considered for application of co-generation to take advantage of higher thermal efficiency and consequent energy cost avoidance. Modern resort hotels require comfort and reliability from mechanical and electrical systems on an around the clock basis. Load profiling reveals simultaneous process heating and electricity use requirements that aid in the selection and sizing of co-generation equipment. Resort Hotel needs include electrical loads for lighting, fan motors, elevators, escalators and receptacle uses. Process heat demands arise from kitchen, servery, banquet, restaurant, laundry, and bakery functions. Once the loads requiring service have been quantified and realigned (shifted) to maximize simultaneous demands the engineering task of co-generation application becomes one of economics. National legislation is now in place to foster the use of co-generating central utility plants. Serving utility companies are now by law required to buy back excess energy during periods of reduced hotel demands. Resort Hotel loads, converted into electricity and heat demands are tabulated in terms of savings (positive cash flow) or costs (negative cash flows). Cash flow tabulations expressed in graphs are included. The graphs show the approximate simple payback on initial costs of co-generation systems based on varying electricity charges.

Baker, T.D.

1986-01-01T23:59:59.000Z

47

Spa Motel Pool & Spa Low Temperature Geothermal Facility | Open Energy  

Open Energy Info (EERE)

Spa Motel Pool & Spa Low Temperature Geothermal Facility Spa Motel Pool & Spa Low Temperature Geothermal Facility Jump to: navigation, search Name Spa Motel Pool & Spa Low Temperature Geothermal Facility Facility Spa Motel Sector Geothermal energy Type Pool and Spa Location White Sulphur Springs, Montana Coordinates 46.548277°, -110.9021561° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

48

Caliente Hot Springs Motel Pool & Spa Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Motel Pool & Spa Low Temperature Geothermal Facility Motel Pool & Spa Low Temperature Geothermal Facility Jump to: navigation, search Name Caliente Hot Springs Motel Pool & Spa Low Temperature Geothermal Facility Facility Caliente Hot Springs Motel Sector Geothermal energy Type Pool and Spa Location Caliente, Nevada Coordinates 37.6149648°, -114.5119378° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

49

Charles Motel & Bathhouse Pool & Spa Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Motel & Bathhouse Pool & Spa Low Temperature Geothermal Facility Motel & Bathhouse Pool & Spa Low Temperature Geothermal Facility Jump to: navigation, search Name Charles Motel & Bathhouse Pool & Spa Low Temperature Geothermal Facility Facility Charles Motel & Bathhouse Sector Geothermal energy Type Pool and Spa Location Truth or Consequences, New Mexico Coordinates 33.1284047°, -107.2528069° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

50

Category:SmallHotel | Open Energy Information  

Open Energy Info (EERE)

SmallHotel SmallHotel Jump to: navigation, search Go Back to PV Economics By Building Type Media in category "SmallHotel" The following 77 files are in this category, out of 77 total. SVSmallHotel Bismarck ND Montana-Dakota Utilities Co (North Dakota).png SVSmallHotel Bismarck ... 71 KB SVSmallHotel International Falls MN Northern States Power Co (Minnesota) Excel Energy.png SVSmallHotel Internati... 83 KB SVSmallHotel LA CA City of Los Angeles California (Utility Company).png SVSmallHotel LA CA Cit... 87 KB SVSmallHotel Memphis TN City of Memphis Tennessee (Utility Company).png SVSmallHotel Memphis T... 65 KB SVSmallHotel Minneapolis MN Northern States Power Co (Minnesota) Excel Energy.png SVSmallHotel Minneapol... 83 KB SVSmallHotel Minot ND Montana-Dakota Utilities Co (North Dakota).png

51

Category:LargeHotel | Open Energy Information  

Open Energy Info (EERE)

LargeHotel LargeHotel Jump to: navigation, search Go Back to PV Economics By Building Type Media in category "LargeHotel" The following 77 files are in this category, out of 77 total. SVLargeHotel Bismarck ND Montana-Dakota Utilities Co (North Dakota).png SVLargeHotel Bismarck ... 70 KB SVLargeHotel International Falls MN Northern States Power Co (Minnesota) Excel Energy.png SVLargeHotel Internati... 85 KB SVLargeHotel LA CA City of Los Angeles California (Utility Company).png SVLargeHotel LA CA Cit... 88 KB SVLargeHotel Memphis TN City of Memphis Tennessee (Utility Company).png SVLargeHotel Memphis T... 67 KB SVLargeHotel Minneapolis MN Northern States Power Co (Minnesota) Excel Energy.png SVLargeHotel Minneapol... 85 KB SVLargeHotel Minot ND Montana-Dakota Utilities Co (North Dakota).png

52

The Luxury casino hotel dynamic price strategy practices for the FIT customer segment.  

E-Print Network (OSTI)

??This research paper compares room rate luxury casino hotel pricing pattern between the periods of 4/1/2009 to 6/30/2009). A good price strategy can help a… (more)

Chen, Lei

2009-01-01T23:59:59.000Z

53

Hotel in the Bahamas profits from solar hot water system  

SciTech Connect

On Paradise Island, located in the Bahamas, American Energy Technologies Inc. (AET) recently designed and supplied a domestic solar water heating system for the new Comfort Suites Hotel. AET is a Florida manufacturer of solar thermal collectors. The hotel has 150 rooms. Hot water usage entails the laundry facilities and the limited kitchen facilities. Access to hot showers is more of a luxury in some places, but guests at the Comfort Suites Hotel need not be concerned. During the development of the hotel, it was noted that the high heating costs of the propane-fueled hotel boiler were somewhat prohibitive. Propane cost approximately $1.67/gallon, causing the cost of heating water for the hotel to be estimated at over $1,000 per month. To offset the high heating costs, a 49-collector system on a 3200 gallon storage tank was designed into the plans for the new facility. The 49 roof mounted collectors were placed on a direct solar link to the 3200 gallon storage tank. The water is preheated before it gets to the boiler, cutting costs tremendously.

1993-01-01T23:59:59.000Z

54

Quark Matter 2004 Conference Hotel  

NLE Websites -- All DOE Office Websites (Extended Search)

as the conference Hotel. It is adjacent to the Oakland Convention Center where all Quark Matter talks will be held. Quark Matter attendees can get a reduced price of 126...

55

ENERGY STAR Success Story: HEI Hotels & Resorts | ENERGY STAR  

NLE Websites -- All DOE Office Websites (Extended Search)

Story: HEI Hotels & Resorts HEI Hotels & Resorts is a growing hospitality company with 30 hotel properties in 13 states. Since launching its partnership with ENERGY STAR in 2006,...

56

Drainable evacuated tubular solar cooling system at Frenchman's Reef Hotel  

SciTech Connect

The Frenchman's Reef Hotel in the Virgin Islands operates its own total energy plant which has the capacity to satisfy the entire requirements of the 510-room hotel for electricity, desalinated drinking water and sewage treatment. The solar energy system consists of a 13,384 square foot array of drainable evacuated tube collectors arranged on three wings of the hotel. Solar heated water is supplied to a 200 ton absorption chiller which cools public rooms in the hotel. A programmable microprocessor controller oversees all functions of the solar energy system and monitors and records data which can be subsequently recovered locally or over the telephone, either as hard copy printout or on tape. The construction and startup of the array and system operating results are discussed. System heat losses are assessed. (LEW)

Platt, D.M.

1981-05-01T23:59:59.000Z

57

Spinning Reserve From Hotel Load Response: Initial Progress  

SciTech Connect

This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby and Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.

Kueck, John D [ORNL; Kirby, Brendan J [ORNL

2008-11-01T23:59:59.000Z

58

Hotels & Accommodations - Clean Cities Transportation Workshop...  

NLE Websites -- All DOE Office Websites (Extended Search)

Hotels & Accommodations Workshops Clean Cities Transportation Workshop for Almaty KZ Workshop Home First Announcement (EN), PDF 288KB First Announcement (RU), PDF 404KB Trainers &...

59

Hotel Scoring Model FAQs | ENERGY STAR  

NLE Websites -- All DOE Office Websites (Extended Search)

use per square foot, and service levels based on operating characteristics. Download the ENERGY STAR Hotel Rating Model FAQs here. Energy Efficient Products Learn about ENERGY...

60

Hotel energy use contributes to global warming.  

E-Print Network (OSTI)

??Before learning about the consequences of global warming and the efforts hotels are making to reverse the effects, it is important to get a better… (more)

Faja, Christine

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Energy End-Use Patterns in Full-Service Hotels: A Case Study  

SciTech Connect

The U.S. Department of Energy (DOE) recently initiated a program -- Commercial Building Partnerships (CBP) -- to work with private-sector companies in the design of highly-efficient retrofit and new construction projects. Pacific Northwest National Laboratory (PNNL) is conducting a project with a major hotel company to retrofit a full-service, large hotel with the goal of reducing energy consumption by at least 30%. The first step of the project was an intensive metering and monitoring effort aimed at understanding energy end use patterns in the hotel. About 10% of the guest rooms (32), as well as circuits for most of the end uses in public spaces (lighting, elevators, air handlers and other HVAC system components, and various equipment), were equipped with meters. Data are being collected at 1- or 5-minute intervals and downloaded on a monthly basis for analysis. This paper presents results from the first four months of the monitoring effort, which revealed energy end-use consumption patterns, variability of guest room energy use, daily load curves, monthly variations, and other aspects of hotel energy use. Metered end-use data for hotels at this level of detail are not available from any currently-available public sources. This study presents unique information and insight into energy end-use patterns in the lodging sector of commercial buildings and can also serve as a case study of a complex sub-metering project.

Placet, Marylynn; Katipamula, Srinivas; Liu, Bing; Dirks, James A.; Xie, YuLong; Sullivan, Greg; Walent, Jim; Williamson, Rebecca

2010-06-30T23:59:59.000Z

62

Symes Hotel and Medicinal Springs Pool & Spa Low Temperature...  

Open Energy Info (EERE)

Hotel and Medicinal Springs Pool & Spa Low Temperature Geothermal Facility Facility Symes Hotel and Medicinal Springs Sector Geothermal energy Type Pool and Spa Location Hot...

63

Glenwood Hot Springs Hotel Pool & Spa Low Temperature Geothermal...  

Open Energy Info (EERE)

Hotel Pool & Spa Low Temperature Geothermal Facility Facility Glenwood Hot Springs Hotel Sector Geothermal energy Type Pool and Spa Location Glenwood Springs, Colorado...

64

Servidyne Systems and The Ritz Carlton Hotel Company: SPP Success Story |  

NLE Websites -- All DOE Office Websites (Extended Search)

Systems and The Ritz Carlton Hotel Company: SPP Success Systems and The Ritz Carlton Hotel Company: SPP Success Story Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In This Section Campaigns Commercial building design Communications resources Energy management guidance Financial resources Portfolio Manager Products and purchasing Recognition Research and reports Service and product provider (SPP) resources

65

SPP sales flyer for hospitality and hotels | ENERGY STAR Buildings & Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

hospitality and hotels hospitality and hotels Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In This Section Campaigns Commercial building design Communications resources Energy management guidance Financial resources Portfolio Manager Products and purchasing Recognition Research and reports Service and product provider (SPP) resources Success stories Target Finder Technical documentation

66

Eficiencia energtica y energas renovables en los hoteles de Uruguay  

E-Print Network (OSTI)

-Mashaqbah, S., Mashal, K., & Mohsen, M. (2008). Potential of energy savings in the hotel sector in Jordan identifying energy consumption, attitudes, willingness and practices of certain classified hotels. The data classified hotels had installed energy saving tools, and only (2 -5) higher starred hotels managers were

Escolano, Francisco

67

Spinning reserve from hotel load response  

SciTech Connect

Even though preliminary tests were not conducted during times of highest system or hotel loading during the summer, they showed that hotel load can be curtailed by 22 to 37 percent depending on the outdoor temperature and time of day. Full response occurred in 12 to 60 seconds from when the system operator's command to shed load was issued and the load drop was very rapid. (author)

Kirby, Brendan; Kueck, John; Laughner, Theo; Morris, Keith

2008-12-15T23:59:59.000Z

68

REDUCTIONS WITHOUT REGRET: AVOIDING WRONG TURNS, ROACH MOTELS, AND BOX CANYONS  

SciTech Connect

This is the third of three papers (in addition to an introductory summary) aimed at providing a framework for evaluating future reductions or modifications of the U.S. nuclear force, first by considering previous instances in which nuclear-force capabilities were eliminated; second by looking forward into at least the foreseeable future at the features of global and regional deterrence (recognizing that new weapon systems currently projected will have expected lifetimes stretching beyond our ability to predict the future); and third by providing examples of past or possible undesirable outcomes in the shaping of the future nuclear force, as well as some closing thoughts for the future. In this paper, we provide one example each of our judgments on what constitutes a box canyon, a roach motel, and a wrong turn: ? Wrong Turn: The Reliable Replacement Warhead ? Roach Motel: SRAM T vs the B61 ? A Possible Box Canyon: A Low-Yield Version of the W76 SLBM Warhead Recognizing that new nuclear missions or weapons are not demanded by current circumstances ? a development path that yields future capabilities similar to those of today, which are adequate if not always ideal, and a broader national-security strategy that supports nonproliferation and arms control by reducing the role for, and numbers, of nuclear weapons ? we briefly consider alternate, less desirable futures, and their possible effect on the complex problem of regional deterrence. In this regard, we discuss the issues posed by, and possible responses to, three example regional deterrence challenges: in-country defensive use of nuclear weapons by an adversary; reassurance of U.S. allies with limited strategic depth threatened by an emergent nuclear power; and extraterritorial, non-strategic offensive use of nuclear weapons by an adversary in support of limited military objectives against a U.S. ally.

Swegle, J.; Tincher, D.

2013-09-11T23:59:59.000Z

69

Jebel Ali Hotel PV lighting systems  

SciTech Connect

A large stand-alone PV lighting project was installed in June 1983 at the Jebel Ali Hotel in Dubai, United Arab Emirates. A high mast lighting system provides illumination for a 130 meter diameter traffic roundabout. The high mast system is powered by a 15 kilowatt peak array of Mobil Solar ribbon PV modules. Along the 700 meter access road leading to the hotel entrance, twenty-one PV powered streetlights provide low-level lighting. Each streetlight consists of a 20 watt fluorescent tube powered by two 35 Wp modules. Operation of both systems is completely automatic. Design, installation, and operating experience to date are reviewed.

Ellis, M.

1984-05-01T23:59:59.000Z

70

Assessing the applicability of trigeneration in the hotel sector  

Science Conference Proceedings (OSTI)

The objective of the present work is to propose a methodology through which the decision makers can assess the feasibility of promoting trigeneration systems in the hotel industry. The power demand of a representative hotel in N. Cyprus was monitored ... Keywords: absorption chiller, economical analysis, energy, hotels, trigeneration

M. Ozdenefe; U. Atikol

2010-02-01T23:59:59.000Z

71

COLLEGE OF HOTEL ADMINISTRATION SUMMARY: UNLV CAREER OUTCOMES 2008 -2009  

E-Print Network (OSTI)

UTILIZED BY HOTEL ADMINISTRATION STUDENTS #1 UNLV CareerLink (Online Recruiting System) #2 UNLV Career DayCOLLEGE OF HOTEL ADMINISTRATION SUMMARY: UNLV CAREER OUTCOMES 2008 - 2009 Summary of the Career! For College of Hotel Administration graduates, 82% of all respondents indicated they worked while attending

Hemmers, Oliver

72

STATISTICAL MECHANICS CONFERENCE HOTEL INFORMATION The following hotels can be used during the conference and will provide a discounted rate. When making your reservation please mention  

E-Print Network (OSTI)

conference stay at this hotel and will utilize the shuttle service) Convenient to Rutgers University ­ lessSTATISTICAL MECHANICS CONFERENCE HOTEL INFORMATION The following hotels can be used during Hotel front desk: 732-828-8000 | Hotel fax: 732-220-0314 Howard Johnson Express Inn official website

Glashausser, Charles

73

Index of /2006_SNAPCollab/hotel_files  

NLE Websites -- All DOE Office Websites (Extended Search)

hotel_files hotel_files Icon Name Last modified Size Description [DIR] Parent Directory - [IMG] 1bancroft_hotel.gif 07-Sep-2007 17:56 23K [IMG] FH_logo.jpg 07-Sep-2007 17:56 4.1K [IMG] beau_sky.gif 07-Sep-2007 17:56 12K [IMG] claremont.gif 07-Sep-2007 17:56 20K [IMG] doubletree.jpg 07-Sep-2007 17:56 23K [IMG] holidayinn.gif 07-Sep-2007 17:56 3.6K [IMG] hoteldurant.gif 07-Sep-2007 17:56 8.0K [IMG] radisson.gif 07-Sep-2007 17:56 4.1K [IMG] ramadalogo.gif 07-Sep-2007 17:56 9.4K [IMG] sh_hp_logo.gif 07-Sep-2007 17:56 2.7K [IMG] shattuck_hotel.gif 07-Sep-2007 17:56 5.8K [IMG] travelodge.gif 07-Sep-2007 17:56 8.2K

74

Archive Reference Buildings by Building Type: Large Hotel | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Large Hotel Large Hotel Archive Reference Buildings by Building Type: Large Hotel Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available. You can download ZIP files that contain the following: An EnergyPlus software input file (.idf) An html file showing the results from the EnergyPlus simulation (.html) A spreadsheet that summarizes the inputs and results for each location (.xls) The EnergyPlus TMY2 weather file (.epw). benchmark-v1.0_3.0-large_hotel.zip benchmark-v1.1_3.1-large_hotel.zip benchmark-new-v1.2_4.0-large_hotel.zip More Documents & Publications Archive Reference Buildings by Building Type: Small Hotel

75

Preplanning gives savings in new hotel construction  

SciTech Connect

A new trend toward preplanning energy conservation in new hotel design is lowering energy costs for new construction 25 to 50%. The architectural/engineering preplanning options that can accomplish an energy goal and be integrated into the architectural/engineering process include how the building is oriented, how much and what kind of glass it contains, what energy-management systems will be installed, and whether to include cogeneration with waste-heat recovery systems. (DCK)

Watson, F.

1983-11-07T23:59:59.000Z

76

Update to ENERGY STAR Ratings for Hotels, FAQs  

NLE Websites -- All DOE Office Websites (Extended Search)

Update to ENERGY STAR Ratings for Hotels Update to ENERGY STAR Ratings for Hotels May 2009 Frequently Asked Questions EPA's energy performance rating system evaluates actual, as-billed energy data to create a whole building indicator of energy performance and compare a building to its national peer group. EPA analyzes national survey data, develops regression models to predict energy use based on operation, and assigns a 1-to-100 rating to a building. Each point on the performance scale represents one percentile of buildings. A full overview of this process and specific details on the hotel model are available online. 1 A revised rating model for hotels was released into Portfolio Manager on February 23, 2009. How was the Hotel Model Updated? The new hotel model incorporates several updates to the original model, as described below. All of the changes have

77

1999 Baldrige Award Recipient, Ritz-Carlton Hotel Company ...  

Science Conference Proceedings (OSTI)

... Ritz-Carlton President and Chief Operating Officer Horst Schulze began his career in the hospitality industry as a waiter's apprentice at a hotel in ...

2010-10-05T23:59:59.000Z

78

Servidyne Systems and The Ritz Carlton Hotel Company: SPP Success...  

NLE Websites -- All DOE Office Websites (Extended Search)

performance ratings through ENERGY STAR. Download the Servidyne Systems and Ritz Carlton Hotel Company SPP Success Story here. Energy Efficient Products Learn about ENERGY STAR...

79

Greening in the United States hotel sector: An exploratory examination.  

E-Print Network (OSTI)

??The aim of this paper is to explore the concept of greening in the U.S. hotel sector. Much of the existing research on the topic… (more)

Kaplan, Adam

2008-01-01T23:59:59.000Z

80

Hotel restaurant concept selection considerations: Which factors to take into account?.  

E-Print Network (OSTI)

??Hotels fulfill a variety of roles in our society. For many travelers and vacationers, a hotel is a home away from home. A wide range… (more)

Bakker, Michiel A.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

COLLEGE OF HOTEL ADMINISTRATION SUMMARY: UNLV CAREER OUTCOMES 2007 -2008  

E-Print Network (OSTI)

Outcomes Survey conducted by Career Services after graduation TOP 7 CAREER SERVICES UTILIZED BY HOTELCOLLEGE OF HOTEL ADMINISTRATION SUMMARY: UNLV CAREER OUTCOMES 2007 - 2008 Summary of the Career of Hotel Administration graduates, 84% of respondents indicated they worked while attending school, about

Hemmers, Oliver

82

Forecasting Hotel Arrivals and Occupancy Using Monte Carlo Simulation  

E-Print Network (OSTI)

Forecasting Hotel Arrivals and Occupancy Using Monte Carlo Simulation Athanasius Zakhary Faculty University, Giza, Egypt (n.elgayar@fci-cu.edu.eg) #12;Abstract Forecasting hotel arrivals and occupancy simulation approach for the arrivals and occupancy forecasting problem. In this approach we simulate

Atiya, Amir

83

ENERGY STAR Success Story: HEI Hotels & Resorts, August 2009  

NLE Websites -- All DOE Office Websites (Extended Search)

HEI Hotels & Resorts HEI Hotels & Resorts HEI Hotels & Resorts is a growing hospitality company with 30 hotel properties in 13 states. Since launching its partnership with ENERGY STAR in 2006, HEI has expanded its corporate commitment to become an industry leader in sustainability initiatives, demonstrating that environmentally sound projects can be financially sound projects as well. HEI has earned the ENERGY STAR for two hotel properties, and has been recognized by the Association of Energy Engineers with the 2009 International Corporate Energy Management Award. Energy Management with ENERGY STAR HEI has integrated the ENERGY STAR strategic approach to energy management in all facets of its business - from procurement of ENERGY STAR qualified lighting, HVAC, computer, and commercial

84

How much sense do room occupancy sensor controls make  

SciTech Connect

Hotel operators are faced with a confusing array of both remote and local guest room energy control devices. A wide variety of decentralized electronic room controllers, each with its own control logic and vendor claims are in competition with remote front desk microprocessor controls which are essentially ''blind'' to actual occupancy. This paper is a review of the characteristics of various controllers, their behaviour with different in-room environmental equipment, and guest reactions to the potpourri of available devices.

Becker, H.P.

1986-01-01T23:59:59.000Z

85

Peppermill Hotel Casino Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Peppermill Hotel Casino Space Heating Low Temperature Geothermal Facility Peppermill Hotel Casino Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Peppermill Hotel Casino Space Heating Low Temperature Geothermal Facility Facility Peppermill Hotel Casino Sector Geothermal energy Type Space Heating Location Reno, Nevada Coordinates 39.5296329°, -119.8138027° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

86

SunShot Concentrating Solar Power Program Review 2013 - Hotel...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

SunShot Concentrating Solar Power Program Review 2013 April 23-25, 2013 Phoenix, Arizona Skip navigation to main content Menu Home About Agenda Register Venue Presentations Hotel...

87

Spinning Reserve from Hotel Air Conditioning Load - SHORT VERSION  

SciTech Connect

Even though preliminary tests were not conducted during times of highest system or hotel loading during the summer, they showed that hotel load can be curtailed by 22 to 37 percent depending on the outdoor temperature and time of day. Full response occurred in 12 to 60 seconds from when the system operator's command to shed load was issued and the load drop was very rapid.

Kueck, John D [ORNL; Kirby, Brendan J [ORNL

2008-01-01T23:59:59.000Z

88

Muon Collider Collaboration Meeting Hotel Information  

NLE Websites -- All DOE Office Websites (Extended Search)

meeting will take place at the Hampton Inn in Orange Beach, AL. This is located on the Gulf of Mexico and is a beachfront resort style setting. The room rate will be 70 per day...

89

InterContinental Hotels Group | Open Energy Information  

Open Energy Info (EERE)

InterContinental Hotels Group InterContinental Hotels Group Jump to: navigation, search Name InterContinental Hotels Group Place Salt Lake City, Utah Zip 84130 Website http://www.intercontinentalhot Coordinates 40.7°, -111.94° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.7,"lon":-111.94,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

90

ENERGY STAR Portfolio Manager Data Trends: Energy Use In Hotels  

NLE Websites -- All DOE Office Websites (Extended Search)

Hotels Hotels The U.S. Environmental Protection Agency's (EPA) ENERGY STAR Portfolio Manager is changing the way organizations track and manage energy. Because of this widespread market adoption, EPA has prepared the DataTrends series to examine benchmarking and trends in energy and water consumption in Portfolio Manager. To learn more, visit www.energystar.gov/DataTrends. Energy use intensity (EUI) ranges from less than 100 to more than 800 kBtu/ft 2 across all hotel buildings, with those at the 95th percentile using almost 4 times the energy of those at the 5th percentile. The distribution has a negative skew, which means the most energy intensive buildings are much further away from

91

Fusion Energy Sciences Advisory Committee Meeting Marriott Hotel (301-590-0044)  

E-Print Network (OSTI)

/Registration - Sheraton Hotel 12:00pm ­ 10:00pm Students arrive throughout the day 11:00am Box lunches Sheraton Hotel ·Hill Top ·SSRL 5:15pm Shuttle Bus from hotels to SLAC ­ Top of the Hill 6:00pm ­ 6:30pm Opening General Transportation to Hotels and/or to Stanford Student Observatory 8:15pm­ 9:30pm Stanford Student Observatory Tour

92

Hotel gets 1-yr. payback from propane-fired cogenerator  

SciTech Connect

A Philadelphia Ramada Inn recovered the costs of a $150,000 propane-fired cogenerator system within a year. The system reduced the energy consumed for hot water and air conditioning by 35% and reversed the high energy costs the hotel incurred when it was forced to shift from natural gas to electricity. The 170 horsepower system, which handles a variety of liquid and gaseous fuels as well as propane, replaces two boilers that were used to heat water. The hotel supplements cogenerated power with purchases from the utility. Waste heat is recaptured for space and water heating. The system's overall efficiency is 96%.

Barber, J.

1983-08-22T23:59:59.000Z

93

WastetoEnergy using Fuel Cells Workshop Capital Hilton Hotel, Washington DC  

E-Print Network (OSTI)

nice hotel near the top from which the ski slopes drop to the lakeshore, and it is here in the early 1900's ­ spent time in the Koli region and at the mountain hotel in particular. They came. Looking from the mountain top hotel out toward the lake. #12;The reason for our visit also had something

94

Typically, hotel bathroom lights are left on between five to eight hours per occupied  

E-Print Network (OSTI)

, receptions, coffee breaks, ground transportation, and conference materials. You are responsible for all hotel costs. CONFERENCE HOTELS Crown Plaza Cabana 4290 El Camino Real Palo Alto, CA 94306 Do not call the hotel directly for reservations. All reservations will be handled through The DANI Group once your

95

Exploring user-producer interaction in an online community: the case of Habbo Hotel  

Science Conference Proceedings (OSTI)

This article attempts to explore the user-producer interaction in the online community of Habbo Hotel. Based on desk research, interviews, an online survey among more than 3000 Habbo Hotel users in The Netherlands and online discussion groups with ... Keywords: Habbo Hotel, The Netherlands, communication, online communities, online safety, user-generated content, user-producer interaction, virtual communities, web-based communities

Mijke Slot

2008-11-01T23:59:59.000Z

96

Reserve asset values and the "hotelling valuation principle"  

E-Print Network (OSTI)

The Hotelling Valuation Principle, that the in-situ value of a mineral unit equals the current net price, is a special case of a more general relation. Tested against a set of recent Canadian sales of oil and gas reserves, ...

Adelman, Morris Albert

1992-01-01T23:59:59.000Z

97

The Philadelphia Marriott: A convention center flagship hotel  

SciTech Connect

This article describes the state-of-the-art HVAC system at the Philadelphia Marriott Hotel. Thermal comfort and indoor air quality are emphasized. The system uses a hybrid gas absorption/electric centrifugal chilled water plant, variable flow pumping, water-side economizers to provide free cooling, central air handling units with air-side economizers and flow monitoring equipment.

Shulman, M.S. [Giovanetti-Shulman Associates, Drexel Hill, PA (United States); Mattocks, J. [Mechanical Design International, Inc., Ellicott City, MD (United States)

1997-01-01T23:59:59.000Z

98

Stroppel Hotel Space Heating Low Temperature Geothermal Facility | Open  

Open Energy Info (EERE)

Space Heating Low Temperature Geothermal Facility Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Stroppel Hotel Space Heating Low Temperature Geothermal Facility Facility Stroppel Hotel Sector Geothermal energy Type Space Heating Location Midland, South Dakota Coordinates 44.0716539°, -101.1554178° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

99

Performance of a hotel chilled water plant with cool storage  

SciTech Connect

A comprehensive monitoring suite was installed at a large convention hotel located in San Francisco, CA. The instrumentation was used for a research project to evaluate the effectiveness of electricity price based controls that automate response to real time pricing and to characterize the operation and performance of the hotel's chilled water plant that included a newly installed ice cool storage system. The hotel operates under real-time electricity rates. To date, over four years of data have been collected. Data included electricity use for all chillers, secondary coolant, chilled water, condenser pumps, and the cooling tower fans. Thermal flow data were also collected for the storage system, ice chiller, direct cooling chillers, and chilled water load loops. This paper (1) describes the chilled water plant, (2) defines the performance measurement objectives for the project, (3) discusses operational experience with the plant, focusing on the cool storage system, (4) analyzes chilled water plant and cool storage system operation by examining the charge/discharge heat flow data, and (5) evaluates how well the plant as a whole and the cool storage system specifically met cooling loads of the facility, and how this affected their use.

Gillespie, K.L.; Blanc, S.L.; Parker, S.

1999-07-01T23:59:59.000Z

100

Commercial Reference Building: Large Hotel | OpenEI  

Open Energy Info (EERE)

Hotel Hotel Dataset Summary Description Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus simulation software. Included here is data pertaining to the reference building type Large Hotel for each of the 16 climate zones, and each of three construction categories: new construction, post-1980 construction existing buildings, pre-1980 construction existing buildings.The dataset includes four key components: building summary, zone summary, location summary and a picture. Building summary includes details about: form, fabric, and HVAC. Zone summary includes details such as: area, volume, lighting, and occupants for all types of zones in the building. Location summary includes key building information as it pertains to each climate zone, including: fabric and HVAC details, utility costs, energy end use, and peak energy demand.In total, DOE developed 16 reference building types that represent approximately 70% of commercial buildings in the U.S.; for each type, building models are available for each of the three construction categories. The commercial reference buildings (formerly known as commercial building benchmark models) were developed by the U.S. Department of Energy (DOE), in conjunction with three of its national laboratories.Additional data is available directly from DOE's Energy Efficiency & Renewable Energy (EERE) Website, including EnergyPlus software input files (.idf) and results of the EnergyPlus simulations (.html).

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Workshop on Renewable Energy Certificate (REC) Markets and Challenges Renaissance Washington Hotel, Washington, DC  

E-Print Network (OSTI)

Workshop on Renewable Energy Certificate (REC) Markets and Challenges Renaissance Washington Hotel Berkeley National Laboratory Paul Douglas, California Public Utilities Commission Paul Helgeson, Wisconsin

102

Reactivation or expansion of Hotel Baker Hydro plant. Feasibility assessment report  

SciTech Connect

The Hotel Baker Hydroelectric Power plant, built in 1928 at St. Charles, IL., has two generating units which until 1970 supplied the hotel with 100 kW output at 6 ft. head. The feasibility of reactivating, upgrading, or replacing these units to again supply power for the hotel was evaluated considering installation and operating costs, financing requirements, environmental impacts, and regulatory requirements. It was concluded that the reactivation project is marginally attractive only with full use of the power output by an expanded hotel and if electric utility rates increase at 8% per year. (LCL)

1979-03-01T23:59:59.000Z

103

An Analysis of the environmental content of Las Vegas Strip hotels.  

E-Print Network (OSTI)

??This study examines the environmental content of hotel properties websites. The central question of this study is whether Las Vegas Strip properties have gone green,… (more)

Levey, Andrew M.

2007-01-01T23:59:59.000Z

104

An Investigation of sustainable environmental practices and consumer attitudes & behaviors toward hotel bathroom amenities.  

E-Print Network (OSTI)

??In the 1980s hotel operators became concerned with greening and sustainability. It was at this time the hospitality industry began focusing on energy efficiency and… (more)

Bobbett, Edward James

2010-01-01T23:59:59.000Z

105

Green energy initiatives in the hotel industry: factors influencing adoption decisions.  

E-Print Network (OSTI)

??Adopting green energy initiatives is deemed significant in reducing the carbon footprint of the hotel industry. In general, energy-efficient and renewable energy technologies offer wide… (more)

Halbe, Akanksha

2013-01-01T23:59:59.000Z

106

Development of an Enterprise-wide Energy Information and Utility Monitoring System in a Major Hotel Chain: The Hyatt Hotels Corporation Experience  

E-Print Network (OSTI)

Hyatt Hotels Corporation is currently implementing an enterprise-wide Energy Information and Utility Monitoring System (UMS). New Horizon Technologies and eComponents Technology have teamed to provide an integrated solution that will ultimately include all Hyatt Hotels in North America. In addition, these 120 Hyatt Hotels participate in a monthly web-based energy benchmarking and hotel engineering reporting system. For hotels with Utility Monitoring Systems (UMS) installed, energy and water consumption data is automatically summarized for the web reports. Hotels without the UMS enter monthly utility data manually on the website. The base UMS at the hotels consists of electric, gas and domestic water consumption and local temperature and relative humidity measurements. The Hyatt UMS is one of the first enterprise-wide systems to include domestic water metering. Many hotels elect to install additional sub-metering for major loads or end uses such as chillers, kitchens and laundries. The local hotel UMS consists of a data acquisition system capable of displaying real-time data that also logs 15-minute interval data. The system transfers interval data daily, to a data center and also transfers interval data hourly, via a Local Area Network, to an on-site workstation with a local database. The local workstation permits users to have real-time alarming capability, access to easy-touse data visualization and analysis tools, and the ability to generate both customized and standard daily and monthly reports. Report writing and utility costing software are used to generate daily and month-to-date cost reports. Bill estimation software uses actual utility rate tariff models to create estimates of utility costs for any custom defined period. Data resident in the Hyatt data center is accessible to the individual hotels using a web-based system. Senior engineers with authorization can access data for all Hyatt Hotels in their regions. The corporate energy director and senior management have access to all data in the Hyatt data center. Browser-based hotel benchmarking data is also available through a similar system with an authorization hierarchy. This paper will describe the design and implementation of the Hyatt UMS in detail, review how the system is currently being used by Hyatt personnel, discuss potential future applications and provide an initial look at UMS system-wide data, including a preliminary return on investment (ROI) analysis.

Burke, B.; McBride, J.; Kimble, K.

2003-01-01T23:59:59.000Z

107

Impact of the Great East Japan Earthquake on Hotel Industry in Pacific Tohoku Prefectures: From spatio-temporal dependence of hotel availability  

E-Print Network (OSTI)

This paper investigates the impact of the Great Japan Earthquake (and subsequent tsunami turmoil) on socio-economic activities by using data on hotel opportunities collected from an electronic hotel booking service. A method to estimate both primary and secondary regional effects of a natural disaster on human behavior is proposed. It is confirmed that temporal variation in the regional share of available hotels before and after a natural disaster may be an indicator to measure the socio-economic impact at each district.

Sato, Aki-Hiro

2012-01-01T23:59:59.000Z

108

Hotel dual-cogeneration plant saving 33% on electricity costs  

SciTech Connect

Hotel Del Coronado in California has two cogeneration systems in operation, one gas turbine based, the other an advanced solar photovoltaic installation which cuts its electric bill by $400,000 per year. In order to make the new installation as unobstrusive as possible, the gas turbine and waste heat boiler units were placed underground. The sunlight-to-electricity efficiency of the photovoltaic cogeneration system is about 8% and the thermal conversion efficiency about 50%. That makes for an overall 58% cogeneration efficiency. The design uses silicon solar cells specially designed for concentrator application.

Stambler, I.

1983-09-01T23:59:59.000Z

109

Carlson Rezidor Hotel Group Maximizes Revenue Through Improved Demand Management and Price Optimization  

Science Conference Proceedings (OSTI)

Under changing market conditions for the hospitality industry, the Carlson Rezidor Hotel Group CRHG collaborated with JDA Software Group to use operations research to drive higher revenue for its hoteliers and to stay ahead of the competition. This highly ... Keywords: competitor prices, demand forecasting, hospitality, hotel, price elasticity, price optimization, revenue management

Pelin Pekgün; Ronald P. Menich; Suresh Acharya; Phillip G. Finch; Frederic Deschamps; Kathleen Mallery; Jim Van Sistine; Kyle Christianson; James Fuller

2013-01-01T23:59:59.000Z

110

Curriculum for B.S. in Restaurant, Hotel, and Institutional Management  

E-Print Network (OSTI)

Curriculum for B.S. in Restaurant, Hotel, and Institutional Management FIRST YEAR Fall Spring HUSC., Organization 3 NS 1410, Science of Nutrition 4 RHIM 2310, Intro. to Hospitality Mgmt. 3 RHIM 2308, Hotel, Facilities Management 3 ANSC 3404, Cons. Selec./Util. 4 Oral Communications* 3 RHIM 3390, Purchasing in Hosp

Rock, Chris

111

CEF06, Amathus Beach Hotel, Limassol, Cyprus, June 22-24, 2006  

E-Print Network (OSTI)

of Excellence in Low-energy Ion-Beam Research and Applications (LIBRA). Location NCSR "Demokritos" is located been reserved for workshop participants at the President Hotel, Kifissias Avenue, at a special rate by completing the attached form (download) and sending it to the hotel Reservations Department (Ms. Maria

Nagurney, Anna

112

PART I  

NLE Websites -- All DOE Office Websites (Extended Search)

take advantage of travel discounts offered to Federal contractor employee travelers by AMTRAK, hotels, motels, or car rental companies, when use of such discounts would result in...

113

Microsoft Word - SECTION I - 08GO28308_Modification 599  

NLE Websites -- All DOE Office Websites (Extended Search)

take advantage of travel discounts offered to Federal contractor employee travelers by AMTRAK, hotels, motels, or car rental companies, when use of such discounts would result in...

114

Microsoft Word - DE-FE0004001 Full text of Clauses.doc  

NLE Websites -- All DOE Office Websites (Extended Search)

take advantage of travel discounts offered to Federal contractor employee travelers by AMTRAK, hotels, motels, or car rental companies, when use of such discounts would result in...

115

PART I SECTION B SUPPLIES AND SERVICES AND PRICE/COSTS DE-AC36...  

NLE Websites -- All DOE Office Websites (Extended Search)

take advantage of travel discounts offered to Federal contractor employee travelers by AMTRAK, hotels, motels, or car rental companies, when use of such discounts would result in...

116

Part I Section B Supplies and Services and Price/Costs  

NLE Websites -- All DOE Office Websites (Extended Search)

take advantage of travel discounts offered to Federal contractor employee travelers by AMTRAK, hotels, motels, or car rental companies, when use of such discounts would result in...

117

Travel and Entertainment All Airlines  

E-Print Network (OSTI)

, Flying Fields Travel Agencies and Tour Operators Bridge and Road Fees, Tolls Services (Utilities) Wire Institutions Securities Brokers /Dealers Insurance Sales, Underwriting and Premiums Lodging Hotels, Motels

Castillo, Steven P.

118

NIST - Bell Labs Workshop on Large-Scale Complex ...  

Science Conference Proceedings (OSTI)

... tree-like structure in these networks using traditional tools such as ... Information about Hotels/Motels, Food/Dining, Weather, Transportation can be ...

2012-06-06T23:59:59.000Z

119

Visitor Information, Boulder Laboratories  

Science Conference Proceedings (OSTI)

... Visitors must wear a visitor badge at all times while on the NIST campus. Hotels/Motels, NIST Boulder Tours. Food/Dining. Local restaurants. Weather ...

2013-08-23T23:59:59.000Z

120

Public Reading Room  

Office of Legacy Management (LM)

has established a Public Reading Room at 955 has established a Public Reading Room at 955 Mound Road, Miamisburg, Ohio, which contains documents and information related to Mound as required under Section 117(d) of SARA. Copies of key Mound records, including the CERCLA Administrative Record and Information Repository, are kept in the Public Reading Room. The Administrative Record and Information Repository for Mound are updated as new documents are created and an index of documents in the complete collections accompanies each update. The Public Reading Room also contains reference items consisting of technical documents, news clippings, videotapes, journal articles, annual reports, and environmental restoration and decontamination and decommissioning decisional documents. Stakeholders are

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Room Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

of Superefficient Room Air Conditioners year month keywords appliance energy efficiency energy efficiency incentives Market Transformation standards url https isswprod lbl gov...

122

Demolishing Searle's Chinese Room  

E-Print Network (OSTI)

Searle's Chinese Room argument is refuted by showing that he has actually given two different versions of the room, which fail for different reasons. Hence, Searle does not achieve his stated goal of showing ``that a system could have input and output capabilities that duplicated those of a native Chinese speaker and still not understand Chinese''.

Wolfram Schmied

2004-03-08T23:59:59.000Z

123

Alexis Park Hotel, Las Vegas Topic Group Meeting Participants were:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Notes Tuesday, January 20, 1998 8:00-11:30 a.m. Notes Tuesday, January 20, 1998 8:00-11:30 a.m. Alexis Park Hotel, Las Vegas Topic Group Meeting Participants were: Audrey Adamson, UETC Daren Gilbert, State of Nevada James Baranski, State of New York Phil Marbut, Canadian Pacific Railway Kevin Blackwell, US DOT/FRA Bruce Marriott, US DOT/FRA Mike Butler, UETC Kevin Miller, CSX Transportation Sandy Covi, Union Pacific RR Markus Popa, US DOE-OCRWM Ray English, US DOE-NR David Schoendorfer, Norfolk Southern RR Bob Fronczak, AAR John Tijan, US DOT/FRA The group convened at approximately 8:00 a.m. Mr. Butler distributed a meeting agenda, welcomed participants and introduced himself as the new Rail Topic Group lead and facilitator. He introduced Item I, "Existing Business"; specifically the two matrices tasked to the Group by

124

Heating facilities for the MGM Grand Hotel, Reno, Nevada  

SciTech Connect

The MGM Grand Hotel-Reno is located adjacent to an area with a well-documented geothermal resource. Currently, there is a number of entities seeking to determine the exact nature of the resource at the MGM site. This report concerns itself with identifying current natural gas loads within the MGM complex which could be met by geothermal should a source become available. The two principle assumptions upon which the following material is based are (1) that a source of 190/sup 0/F or higher temperature water is available and (2) all systems discussed would be installed in parallel with existing systems. That is, existing systems would remain in place providing 100 percent backup for the geothermal systems.

1981-09-01T23:59:59.000Z

125

Commercial Reference Building: Small Hotel | OpenEI  

Open Energy Info (EERE)

60 60 Varnish cache server Browse Upload data GDR 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142278160 Varnish cache server Commercial Reference Building: Small Hotel Dataset Summary Description Commercial reference buildings provide complete descriptions for whole building energy analysis using EnergyPlus simulation software. Included here is data pertaining to the reference building type Small Hotel for each of the 16 climate zones, and each of three construction categories: new construction, post-1980 construction existing buildings, pre-1980 construction existing buildings.The dataset includes four key components: building summary, zone summary, location summary and a picture. Building summary includes details about: form, fabric, and HVAC. Zone summary includes details such as: area, volume, lighting, and occupants for all types of zones in the building. Location summary includes key building information as it pertains to each climate zone, including: fabric and HVAC details, utility costs, energy end use, and peak energy demand.In total, DOE developed 16 reference building types that represent approximately 70% of commercial buildings in the U.S.; for each type, building models are available for each of the three construction categories. The commercial reference buildings (formerly known as commercial building benchmark models) were developed by the U.S. Department of Energy (DOE), in conjunction with three of its national laboratories.Additional data is available directly from DOE's Energy Efficiency & Renewable Energy (EERE) Website, including EnergyPlus software input files (.idf) and results of the EnergyPlus simulations (.html).

126

SRNL - News Room  

NLE Websites -- All DOE Office Websites (Extended Search)

& Development Projects in the "Press Room" at www.doe.gov for further details.) Expected funding for the SRNL project is estimated at approximately one-half million dollars a year...

127

Glenwood Hot Springs Hotel Pool & Spa Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Hotel Pool & Spa Low Temperature Geothermal Facility Hotel Pool & Spa Low Temperature Geothermal Facility Jump to: navigation, search Name Glenwood Hot Springs Hotel Pool & Spa Low Temperature Geothermal Facility Facility Glenwood Hot Springs Hotel Sector Geothermal energy Type Pool and Spa Location Glenwood Springs, Colorado Coordinates 39.5505376°, -107.3247762° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

128

Emerging patterns of adaptive re-use : the new American House Hotel  

E-Print Network (OSTI)

This thesis aims to develop a design solution for the adaptive reuse of the American House Hotel that answers an architectural design challenge with technical responses. The process of actualization has been pushed a bit ...

Moody, Linda A

1984-01-01T23:59:59.000Z

129

Symes Hotel and Medicinal Springs Pool & Spa Low Temperature Geothermal  

Open Energy Info (EERE)

Symes Hotel and Medicinal Springs Pool & Spa Low Temperature Geothermal Symes Hotel and Medicinal Springs Pool & Spa Low Temperature Geothermal Facility Jump to: navigation, search Name Symes Hotel and Medicinal Springs Pool & Spa Low Temperature Geothermal Facility Facility Symes Hotel and Medicinal Springs Sector Geothermal energy Type Pool and Spa Location Hot Springs, Montana Coordinates 47.6091041°, -114.6687414° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

130

BERAC Meeting May 19-20, 2008 Hilton Hotel Gaithersburg, MD | U.S. DOE  

Office of Science (SC) Website

9-20, 2008 Hilton Hotel Gaithersburg, MD 9-20, 2008 Hilton Hotel Gaithersburg, MD Biological and Environmental Research Advisory Committee (BERAC) BERAC Home Meetings BERAC Minutes BERAC Minutes Archive Members Charges/Reports Charter .pdf file (40KB) BER Committees of Visitors BER Home Meetings BERAC Meeting May 19-20, 2008 Hilton Hotel Gaithersburg, MD Print Text Size: A A A RSS Feeds FeedbackShare Page BERAC Meeting May 19-20, 2008 Hilton Hotel Gaithersburg, MD Agenda .pdf file (17KB) Presentations Mike Hochella .ppt file (388KB), Environmental Remediation Sciences Division Committee of Visitors Report Jim Adelstein .ppt file (1.1MB), Report on the Low Dose Radiation Research Program Himadri Pakrasi .ppt file (22.3MB), Science Talk, Membrane Biology Grand Challenge Jeff Amthor .ppt file (11.7MB), Update on BER Program for Ecosystems

131

Proceedings of the 45th IEEE Conference on Decision & Control Manchester Grand Hyatt Hotel  

E-Print Network (OSTI)

Proceedings of the 45th IEEE Conference on Decision & Control Manchester Grand Hyatt Hotel San towards these two goals utilizing a minimal 3-CMG array to provide 646% singularity-free momentum

132

Volatility of hotel market fundamentals and the determinants of variations between markets  

E-Print Network (OSTI)

How can volatility as well as other dynamics and characteristics in hotel market fundamentals affecting risk be better understood? This paper explores that fundamental question along with other more specific questions that ...

Cason, Brian (Brian Paul)

2010-01-01T23:59:59.000Z

133

Luxury condos : an analysis of sales price and hotel amenities in Manhattan  

E-Print Network (OSTI)

The purpose of this research project is to examine the market pricing behavior of condos with hotel amenities in the Manhattan condo market. To do this, data was compiled from multiple sources to track variations in price ...

Dolan, Amelia Jane

2011-01-01T23:59:59.000Z

134

Solar Energy Program: Chapter from the Energy and Environmental Division Annual Report 1980  

E-Print Network (OSTI)

growth rate of energy use in the hotel and motel category isEnergy's San Francisco Operations Office's (DOE/SAN) overall management of commercial-building solar demonstration projects and hotel/

Energy and Environment Division

1981-01-01T23:59:59.000Z

135

DOE Solar Decathlon: Press Room  

NLE Websites -- All DOE Office Websites (Extended Search)

Bios Press Releases Photos Videos Education Sponsors Volunteers History FAQs Contacts Solar Decathlon Press Room The U.S. Department of Energy Solar Decathlon press room provides...

136

Executive Summary The Morgantown metropolitan statistical area (MSA) continues to be a force for growth in West  

E-Print Network (OSTI)

year growth. Leisure and hospitality includes motels/hotels, bars and restaurants, as well as local at a slower pace, as investments in hotels/motels in the region generate future job gains. Finally Corporation www.bber.wvu.edu This conference is made possible by the following underwriters: Chesapeake Energy

Mohaghegh, Shahab

137

An attempt to value Canadian oil and natural gas reserves : an extension of the hotelling valuation principle .  

E-Print Network (OSTI)

??The importance of the Hotelling Valuation Principle (HVP) in economic study lies in its ability to examine and drive the decision of how much of… (more)

Shumlich, Michael

2008-01-01T23:59:59.000Z

138

Electronic Reading Room  

NLE Websites -- All DOE Office Websites (Extended Search)

Electronic Reading Room - making information about the Freedom of Information Act (FOIA) and Privacy Act process accessible to the public electronically. Electronic Reading Room - making information about the Freedom of Information Act (FOIA) and Privacy Act process accessible to the public electronically. Major Information Systems - Final Opinions - [5 USC 552 (a)(2)](A) final opinions, including concurring and dissenting opinions, as well as orders, made in the adjudication of cases within the Office of Hearings and Appeals Statements of Policy and Interpretation and Administrative Staff Manuals and Instructions - [5 USC 552 (a)(2)](B) those statements of policy and interpretation which have been adopted by the agency and are not published in the Federal Register - Directives, DOE Orders, Headquarters Orders, Secretarial Notices, Technical Standards, Forms, Delegations, Electronic Library Public Reading Facilities - making information available for public inspection and copying

139

Reading Room Locations  

NLE Websites -- All DOE Office Websites (Extended Search)

FOIA Offices and Reading Rooms FOIA Offices and Reading Rooms FOIA Office Locations Our FOIA Officers are located at various sites throughout the DOE complex, each with responsibility for records located at or under the jurisdiction of the site. We recommend that you send your request directly to that specific site. This will shorten the processing time. However, if you do not know which location has responsive records, you may either call the Headquarters FOIA office at (202) 586-5955 to determine the appropriate office, or mail the request to the Headquarters FOIA office. Other records are publicly available in the facilities listed below: Headquarters U.S. Department of Energy FOIA/Privacy Act Group 1000 Independence Avenue, SW Washington, D.C. 20585 Phone: 202-586-5955 Fax: 202-586-0575

140

Stroppel Hotel Pool & Spa Low Temperature Geothermal Facility | Open Energy  

Open Energy Info (EERE)

Stroppel Hotel Pool & Spa Low Temperature Geothermal Facility Stroppel Hotel Pool & Spa Low Temperature Geothermal Facility Facility Stroppel Hotel Sector Geothermal energy Type Pool and Spa Location Midland, South Dakota Coordinates 44.0716539°, -101.1554178° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Red Lion Hotel Richland Hanford House Richland, Washington U. S. DEPARTMENT OF ENERGY  

NLE Websites -- All DOE Office Websites (Extended Search)

Lion Hotel Richland Hanford House Lion Hotel Richland Hanford House Richland, Washington U. S. DEPARTMENT OF ENERGY Performance Assessment Community of Practice Technical Exchange April 13 - 14, 2010 Performance Assessment Community of Practice Technical Exchange 1 Welcome Dear Participant, On behalf of the Department of Energy and the Savannah River National Laboratory, we welcome you to the Performance Assessment Community of Practice Technical Exchange. Each of you bring a wealth of experience from a variety of different perspectives that will be essential for the effective and compliant imple- mentation of performance and risk assessments in support of tank closure, site operations, and area completion projects. The Performance Assess-

142

Proceedings of the 45th IEEE Conference on Decision & Control Manchester Grand Hyatt Hotel  

E-Print Network (OSTI)

Proceedings of the 45th IEEE Conference on Decision & Control Manchester Grand Hyatt Hotel San can supply. For a DES, commonly applied performance metrics include average system time, utilization and operate the system or the resources that the system utilizes, such as communication channels, space, time

Cassandras, Christos G.

143

SICE Annual Conference 2010 August 18-21, 2010, The Grand Hotel, Taipei, Taiwan  

E-Print Network (OSTI)

SICE Annual Conference 2010 August 18-21, 2010, The Grand Hotel, Taipei, Taiwan ¥400 © 2010 SICE. Thus, the proposed system can potentially be utilized in the legged robots where the COM moves due utilized in various applications, including navigation (robots, vehicles, rockets, and etc) [2-4], state

Lin, Pei-Chun

144

Proceedings of the 45th IEEE Conference on Decision & Control Manchester Grand Hyatt Hotel  

E-Print Network (OSTI)

Proceedings of the 45th IEEE Conference on Decision & Control Manchester Grand Hyatt Hotel San describing the left and right turn minimum radius paths of the vehicle. Utilizing this construction, a weak then be utilized to plan shortest path segments in the presence of obstacles in future work. In order to avoid

Barth, Eric J.

145

Fulfilled and missed requirements for online reservation systems: an empirical investigation of austrian and swiss hotels  

Science Conference Proceedings (OSTI)

Temporal data are a core element of a reservation. In this paper we formulate 10 requirements and 14 sub-requirements for handling temporal data in online hotel reservation systems (OHRS) from a usability viewpoint. We test the fulfillment of these requirements ... Keywords: B2C systems, requirements engineering, reservation systems, temporal data, tests, travel, usability

Gerhard F. Knolmayer, Viola Sini, Polina Chelnokova

2013-07-01T23:59:59.000Z

146

Geothermal feasibility study for hotel/apartment complex: Decker Land Development, Tucson, Arizona  

SciTech Connect

The commercial project studied consists of a 200-unit hotel and a 300-unit apartment complex, to be served by a common geothermal system. An additional 200-unit is assumed to be operational within seven years. The following aspects of the geothermal resource, project assumptions, geothermal utilization techniques, and energy analysis techniques.

1982-03-01T23:59:59.000Z

147

Changing How We Choose Hotels Would you pay more to stay in a  

E-Print Network (OSTI)

Fusion Energy Sciences Advisory Committee Meeting March 1-2, 2007 Marriott Hotel/301-590-0044 9751. Raymond L. Orbach, Under Secretary of Science 12:30 Lunch 1:30 Fusion Energy Sciences FY 2008 Budget Tom:45 Discussion of the New Charge FESAC 5:30 Adjourn #12;Fusion Energy Sciences Advisory Committee Meeting March 1

Soerens, Thomas

148

Media Room | National Nuclear Security Administration  

NLE Websites -- All DOE Office Websites (Extended Search)

Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog The National Nuclear Security Administration Media Room Home > Media Room Media Room NNSA's Office of...

149

Proceedings of the 45th IEEE Conference on Decision & Control ThAl8.6 Manchester Grand Hyatt Hotel  

E-Print Network (OSTI)

Proceedings of the 45th IEEE Conference on Decision & Control ThAl8.6 Manchester Grand Hyatt Hotel that the energy efficiency of wireless networks can be greatly improved by utilizing transmission control

Cassandras, Christos G.

150

Select-service hotels : a guide to understanding the lodging industry and one of its most attractive segments  

E-Print Network (OSTI)

This thesis serves as a pedagogical guide to the hospitality industry, and presents a broad overview of the unique issues that arise through the development, ownership and management of select-service franchised hotels. ...

Berger, Brandon B. (Brandon Brooks)

2007-01-01T23:59:59.000Z

151

90.1 Prototype Building Models Large Hotel | Building Energy Codes Program  

NLE Websites -- All DOE Office Websites (Extended Search)

Hotel Hotel The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. This suite of ASHRAE Standard 90.1 prototype buildings covers all the Reference Building types except supermarket, and also adds a new building prototype representing high-rise apartment buildings.The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007 and 90.1-2010. This combination leads to a set of 816 building models (in EnergyPlus Version 6.0). Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the

152

90.1 Prototype Building Models Small Hotel | Building Energy Codes Program  

NLE Websites -- All DOE Office Websites (Extended Search)

Hotel Hotel The ASHRAE Standard 90.1 prototype building models were developed by Pacific Northwest National Laboratory in support of the U.S. Department of Energy's (DOE's) Building Energy Codes Program. These prototype buildings were derived from DOE's Commercial Reference Building Models. This suite of ASHRAE Standard 90.1 prototype buildings covers all the Reference Building types except supermarket, and also adds a new building prototype representing high-rise apartment buildings.The prototype models include 16 building types in 17 climate locations for ASHRAE Standards 90.1-2004, 90.1-2007 and 90.1-2010. This combination leads to a set of 816 building models (in EnergyPlus Version 6.0). Also included is a scorecard for each prototype building. The scorecard is a spreadsheet that summarizes the

153

Cost effective solar hot water system for econo-travel motor hotel located at Hampton, VA  

SciTech Connect

This paper gives the final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 2708 Mercury Boulevard, Hampton, Virginia. The description of the system along with the final cost breakdown, performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

1978-11-01T23:59:59.000Z

154

Cost effective solar hot water system for Econo-Travel Motor Hotel, Chesapeake, Virginia. Final report  

SciTech Connect

The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 4725 W. Military Highway, Chesapeake, Virginia, is presented. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

1978-12-01T23:59:59.000Z

155

3,000 kW Suginoi Hotel geothermal power plant  

SciTech Connect

The Suginoi Hotel is located 200 m above sea level, in Beppu City, which is one of the largest hot spring resort area in Japan. In this hotel, there are some unique hot spring baths, which are interesting to visitors. In Beppu, there are numerous hot springs, some are call {open_quotes}Jigoku{close_quotes} (Hells). The main attraction in Beppu are the hell-like spots created by hot springs such as the Torando Hell, which erupt to a heights of more than 50 meters, The Blood Pond Hell which is bloody red due to red clay content. In yield, these hot springs rank second in the world next to those of Yellowstone National Park in the USA.

Kudo, Kisumi [Beppu Suginoi Hotel, Beppu (Japan)

1996-05-01T23:59:59.000Z

156

Cost effective solar hot water system for econo-travel motor hotel located at Hampton, VA  

DOE Green Energy (OSTI)

This paper gives the final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 2708 Mercury Boulevard, Hampton, Virginia. The description of the system along with the final cost breakdown, performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

Not Available

1978-11-01T23:59:59.000Z

157

Cost effective solar hot water system for Econo-Travel Motor Hotel, Chesapeake, Virginia. Final report  

DOE Green Energy (OSTI)

The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 4725 W. Military Highway, Chesapeake, Virginia, is presented. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

Not Available

1978-12-01T23:59:59.000Z

158

Developing a localisation indicator for chain hotel websites: a Greek case study  

Science Conference Proceedings (OSTI)

Web visitors differ across regional, linguistic and country boundaries and their requirements are strongly influenced by their local cultural perspective. The localisation of a website is the process of adapting it to a particular language, culture and ... Keywords: Greece, business information systems, collectivism, cultural perspectives, culture, evaluation models, femininity, hospitality industry, hotel chains, hoteliers, individualism, internet, language, linguistic factors, local, localisation indicators, masculinity, power distance, quantitative measurement, tourism, uncertainty avoidance, websites, world wide web

Dimitris Kanellopoulos; Fotis Lazarinis

2010-03-01T23:59:59.000Z

159

Hypercomputation in the Chinese Room  

Science Conference Proceedings (OSTI)

I rehearse a number of objections to John Searle's famous Chinese room argument. One is the 'hypercomputational objection' (Copeland 2002a). Hypercomputation is the computation of functions that cannot be computed in the sense of Turing (1936); the term ...

B. Jack Copeland

2002-10-01T23:59:59.000Z

160

Heater/cooler unit  

SciTech Connect

Air conditioning apparatus especially adapted for cooling adjacent rooms in a motel, hotel, hospital or like structure is described comprising: a first evaporator disposed in one room; a second evaporator disposed in an adjacent room; a condenser disposed outside the rooms but in fluid communication with both the first and second evaporators; a compressor disposed outside the rooms but in fluid communication with the condenser and with a return side of the first and second evaporators; control means for controlling the fluid flow through each evaporator, the control means permitting fluid flow through the first evaporator to be controlled independently of fluid flow through the second evaporator; and a housing exposed to the atmosphere through the exterior wall of the structure and forming a portion of the common interior wall of the rooms, the evaporators, condenser, compressor, and control means being disposed within the housing.

Mintz, A.

1988-01-26T23:59:59.000Z

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Nuclear reactor control room construction  

DOE Patents (OSTI)

A control room for a nuclear plant is disclosed. In the control room, objects labelled 12, 20, 22, 26, 30 in the drawing are no less than four inches from walls labelled 10.2. A ceiling contains cooling fins that extend downwards toward the floor from metal plates. A concrete slab is poured over the plates. Studs are welded to the plates and are encased in the concrete. 6 figures.

Lamuro, R.C.; Orr, R.

1993-11-16T23:59:59.000Z

162

Reading Room | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Freedom of Information Act » Reading Freedom of Information Act » Reading Room Reading Room Welcome to the Freedom of Information Act (FOIA) Electronic Reading Room for the Department of Energy at Headquarters. The FOIA requires certain kinds of documents to be made available to the public for inspection and copying. This is a requirement for agencies of the executive branch of the federal government. The documents that are required to be made available by the FOIA are: Final Opinions [5 USC 552 (a)(2)](A) final opinions, including concurring and dissenting opinions, as well as orders, made in the adjudication of cases. Office of Hearings and Appeal - FOIA Appeals Initial agency determinations in response to FOIA and Privacy Act requests may be appealed to the Office of Hearings and Appeals (OHA). Decisions of

163

Reading Room | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Reading Reading Room Reading Room Welcome to the Freedom of Information Act (FOIA) Electronic Reading Room for the Department of Energy at Headquarters. The FOIA requires certain kinds of documents to be made available to the public for inspection and copying. This is a requirement for agencies of the executive branch of the federal government. The documents that are required to be made available by the FOIA are: Final Opinions [5 USC 552 (a)(2)](A) final opinions, including concurring and dissenting opinions, as well as orders, made in the adjudication of cases. Office of Hearings and Appeal - FOIA Appeals Initial agency determinations in response to FOIA and Privacy Act requests may be appealed to the Office of Hearings and Appeals (OHA). Decisions of the OHA constitute the agency's final determinations on requests made under

164

Room temperature terahertz polariton emitter  

SciTech Connect

Terahertz (THz) range electroluminescence from intersubband polariton states is observed in the ultra strong coupling regime, where the interaction energy between the collective excitation of a dense electron gas and a photonic mode is a significant portion of the uncoupled excitation energy. The polariton's increased emission efficiency along with a parabolic electron confinement potential allows operation up to room temperature in a nonresonant pumping scheme. This observation of room temperature electroluminescence of an intersubband device in the THz range is a promising proof of concept for more powerful THz sources.

Geiser, Markus; Scalari, Giacomo; Castellano, Fabrizio; Beck, Mattias; Faist, Jerome [Institute for Quantum Electronics, ETH Zurich, Wolfgang-Pauli-Strasse 16, 8093 Zurich (Switzerland)

2012-10-01T23:59:59.000Z

165

Hotel Cedes 7 months' savings for total lighting retrofit  

SciTech Connect

In an unusual shared-savings agreement, the Hilton Florida Center at Orlando, where a retrofit program was begun two years ago, will give up all savings from a lighting retrofit program for seven months, avoiding upfront costs of equipment purchase, and will then become sole owner of the equipment and beneficiary of the savings. The four-month-old program has improved the lighting and cut electricity costs $2000 to $2500 per month, which would have been a six-month payback. Contracts for two other hotels are expected where retrofitting has begun. Retrofit details are given.

Warrock, A.M.

1983-07-11T23:59:59.000Z

166

Solar cooling system performance, Frenchman's Reef Hotel, Virgin Islands. Final report  

SciTech Connect

The operational and thermal performance of a variety of solar systems are described. The Solar Cooling System was installed in a hotel at St. Thomas, U. S. Virgin Islands. The system consists of the evacuated glass tube collectors, two 2500 gallon tanks, pumps, computerized controller, a large solar optimized industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat.

Harber, H.

1981-09-01T23:59:59.000Z

167

Field Measurement of Heating System in a Hotel Building in Harbin  

E-Print Network (OSTI)

Heating energy consumption in winter is an important component of the whole building energy consumption in the severe cold zone in north China. This paper presents a heating water system of a hotel building in Harbin, finishes the testing of its heating energy consumption in winter under operational conditions, and presents an stimation index of the performance of an exchanger, pump and motor. Analysis of device running conditions based on testing data is conducted. Results show that low stream supply temperature and wide-range flow fluctuation mainly lead to unhealthy working conditions of the device and excessive energy consumption, and a corresponding improved method is presented.

Zhao, T.; Zhang, J.; Li, Y.

2006-01-01T23:59:59.000Z

168

SLAC National Accelerator Laboratory - Meeting Rooms  

NLE Websites -- All DOE Office Websites (Extended Search)

41 144D 3117 30-C Blue Room (20) 41 207 2868 30-C Castle Craigs Conference Room 280B 241 2804 29-D Cedar Room (15) 48 101 3485 30-B CEF Conference Room 35 4A 3534 27-E Controls...

169

City of San Carlos Building Division  

E-Print Network (OSTI)

Residential: The construction of R2, R3, R3.1, and R4 buildings, except hotels and motels. C. Residential of any or all utilities (water, electrical, natural gas, or sewer); or the project provided no permanent

170

West Virginia Higher Education Graduate  

E-Print Network (OSTI)

the importance of the energy sector to the state. The coal and natural gas sectors continued to post strong includes hotels, motels, restaurants, and bars. It also includes the gaming sector. #12;W.Va. Graduate

Mohaghegh, Shahab

171

Hotel archiphilia  

E-Print Network (OSTI)

Jean-Francois de Bastide's mid-eighteenth century novel, The Little House, describes an erotic encounter between a persistent man, and a reluctant woman. More remarkably, the novel introduces a third character, the estate ...

Jusczyk, Thaddeus P

2009-01-01T23:59:59.000Z

172

DOE Solar Decathlon: Press Room  

NLE Websites -- All DOE Office Websites (Extended Search)

Press Room Press Room The U.S. Department of Energy Solar Decathlon is an award-winning program that challenges collegiate teams to design, build, and operate solar-powered houses that are cost-effective, energy-efficient, and attractive. The winner of the competition is the team that best blends affordability, consumer appeal, and design excellence with optimal energy production and maximum efficiency. The first Solar Decathlon was held in 2002; the competition has since occurred every two years in 2005, 2007, 2009, and 2011. The last event was held at the National Mall's West Potomac Park in Washington, D.C., Sept. 23-Oct. 2, 2011. Solar Decathlon 2013 takes place Oct. 3-13, 2013, at Orange County Great Park in Irvine, California. Open to the public free of charge, the Solar Decathlon gives visitors the

173

News Room | Argonne National Laboratory  

NLE Websites -- All DOE Office Websites (Extended Search)

News Room News Room In a 3D structure of the protein, the binding site is shown in pink, representing a potential drug target. The green molecule shows binding of an antibiotic to the protein. Click to enlarge. Image courtesy of Wladek Minor. Newly ID'd protein provides target for antibiotic-resistant hospital bacterium Full Story » Researchers have made inroads into tackling a bacterium that plagues hospitals and is highly resistant to most antibiotics. Andrey Elagin (left), postdoctoral scholar at the Enrico Fermi Institute at the University of Chicago, and Matthew Wetstein, the Grainger Postdoctoral Fellow at the Enrico Fermi Institute at the University of Chicago, adjust the optics in the Large Area Picosecond Photodetector testing facility. The facility uses extremely short laser pulses to precisely measure the time resolution of the photodetectors. Click to enlarge.

174

NETL: NewsRoom - Multimedia  

NLE Websites -- All DOE Office Websites (Extended Search)

NewsRoom NewsRoom Multimedia Now you can download videos to your computer by right clicking the "download" link and selecting the "Save target as" option. It is suggested that mac users use this link. Carbon Cycle Animation Carbon Cycle Animation - 2012 Animation that depicts the carbon cycle as it relates to nature, land use, and energy production. Movie Icon Windows Media Video (WMV-5.7MB) [ view | download ] Earth Day Animation Earth Day Animation - 2011 A compilation of three Earth Day animations that demonstrate being green around your home, office, and community Movie Icon Windows Media Video (WMV-16MB) [ view | download ] Interview with Anthony Cugini Interview with Anthony Cugini - 2011 Interview at the International Pittsburgh Coal Conference with Dr. Cugini regarding Carbon Capture Utilization and Storage technologies.

175

A room in the city : housing itinerant lifestyles  

E-Print Network (OSTI)

In a globalized world, people are becoming more transient, and the turnover in cities continues to increase. For the white-collar labor force, the difference between residing and staying is becoming less defined. Hotel and ...

Webster, Meghan Elizabeth

2008-01-01T23:59:59.000Z

176

A Small-Business Guide: Lodging  

Science Conference Proceedings (OSTI)

Members of the small business community historically have had little contact with their utility providers. This guidebook was developed to facilitate communication between electric utilities and the motels and hotels in their communities. The Lodging guidebook is intended to familiarize readers with the business of owning and/or operating motels and hotels by providing a historic overview of the lodging industry and summarizing its current issues and challenges. The guide specifically focuses on delineat...

1996-12-24T23:59:59.000Z

177

Classified Reading Room Instructions/Guidelines  

NLE Websites -- All DOE Office Websites (Extended Search)

Classified Reading Room Instructions/Guidelines Classified Reading Room Instructions/Guidelines * Reading Room Points of Contact: Milesha Grier, (202) 586-8210, milesha.gier@nnsa.doe.gov Reading Room Location: DOE Forrestal Building, 1000 Independence Ave., Washington, D.C. Room 4A-045, 4 th Floor, "A" Corridor, Behind Glass Doors, dial 6-8210 Reading Room Availability: By Appointment - Reading Room will be available until RFP Closes except (12/5/11 thru 12/16/11, December 23, January 2, 2012 and January 16, 2012). Reading Room Hours: Morning, 9:00 a.m. - 11:30 a.m.; and Afternoon 1:00 p.m. - 3:30 p.m. Reading Room Will Accommodate: Up to 5-6 people * All personnel must: a. submit a formal Intent to Bid IAW Section L of the RFP, via email to: SEB1@doeal.gov

178

Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Room Air Conditioners Room Air Conditioners Room Air Conditioners July 1, 2012 - 5:35pm Addthis A window air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/kschulze. A window air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/kschulze. What does this mean for me? Room air conditioners are less expensive and disruptive to install than central air conditioning systems. Room air conditioners can be a cost-effective alternative to central air conditioning systems. How does it work? Room air conditioners work by cooling one part of your home. Room or window air conditioners cool rooms rather than the entire home or business. If they provide cooling only where they're needed, room air conditioners are less expensive to operate than central units, even though

179

SPIE 's 4TH Annual Symposium on Smart Structures and Materials, paper 3041 -38, Catamaran Resort Hotel, San Diego,  

E-Print Network (OSTI)

Hotel, San Diego, CA, 2-6 March 97 LARGE-AMPLITUDE ROTARY INDUCED-STRAIN (LARIS) ACTUATOR PROOF-strain material stacks is proposed. The concept utilizes the theory of twist-warping coupling in thin-wall open-amplifier utilizing the warping-torsion coupling of an open tube, is a viable design option, of great constructive

Giurgiutiu, Victor

180

Media Room | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Media Room | National Nuclear Security Administration Media Room | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog The National Nuclear Security Administration Media Room Home > Media Room Media Room NNSA's Office of Congressional, Intergovernmental, and Public Affairs regularly updates the web site with current press releases, newsletters,

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Novel room temperature ferromagnetic semiconductors  

SciTech Connect

Today's information world, bits of data are processed by semiconductor chips, and stored in the magnetic disk drives. But tomorrow's information technology may see magnetism (spin) and semiconductivity (charge) combined in one 'spintronic' device that exploits both charge and 'spin' to carry data (the best of two worlds). Spintronic devices such as spin valve transistors, spin light emitting diodes, non-volatile memory, logic devices, optical isolators and ultra-fast optical switches are some of the areas of interest for introducing the ferromagnetic properties at room temperature in a semiconductor to make it multifunctional. The potential advantages of such spintronic devices will be higher speed, greater efficiency, and better stability at a reduced power consumption. This Thesis contains two main topics: In-depth understanding of magnetism in Mn doped ZnO, and our search and identification of at least six new above room temperature ferromagnetic semiconductors. Both complex doped ZnO based new materials, as well as a number of nonoxides like phosphides, and sulfides suitably doped with Mn or Cu are shown to give rise to ferromagnetism above room temperature. Some of the highlights of this work are discovery of room temperature ferromagnetism in: (1) ZnO:Mn (paper in Nature Materials, Oct issue, 2003); (2) ZnO doped with Cu (containing no magnetic elements in it); (3) GaP doped with Cu (again containing no magnetic elements in it); (4) Enhancement of Magnetization by Cu co-doping in ZnO:Mn; (5) CdS doped with Mn, and a few others not reported in this thesis. We discuss in detail the first observation of ferromagnetism above room temperature in the form of powder, bulk pellets, in 2-3 mu-m thick transparent pulsed laser deposited films of the Mn (<4 at. percent) doped ZnO. High-resolution transmission electron microscopy (HRTEM) and electron energy loss spectroscopy (EELS) spectra recorded from 2 to 200nm areas showed homogeneous distribution of Mn substituting for Zn a 2+ state in the ZnO lattice. Ferromagnetic Resonance (FMR) technique is used to confirm the existence of ferromagnetic ordering at temperatures as high as 425K. The ab initio calculations were found to be consistent with the observation of ferromagnetism arising from fully polarized Mn 2+ state. The key to observed room temperature ferromagnetism in this system is the low temperature processing, which prevents formation of clusters, secondary phases and the host ZnO from becoming n-type. The electronic structure of the same Mn doped ZnO thin films studied using XAS, XES and RIXS, revealed a strong hybridization between Mn 3d and O 2p states, which is an important characteristic of a Dilute magnetic Semiconductor (DMS). It is shown that the various processing conditions like sintering temperature, dopant concentration and the properties of precursors used for making of DMS have a great influence on the final properties. Use of various experimental techniques to verify the physical properties, and to understand the mechanism involved to give rise to ferromagnetism is presented. Methods to improve the magnetic moment in Mn doped ZnO are also described. New promising DMS materials (such as Cu doped ZnO are explored). The demonstrated new capability to fabricate powder, pellets, and thin films of room temperature ferromagnetic semiconductors thus makes possible the realization of a wide range of complex elements for a variety of new multifunctional phenomena related to Spintronic devices as well as magneto-optic components.

Gupta, Amita

2004-11-01T23:59:59.000Z

182

SLAC Linac Coherent Light Source User Site  

NLE Websites -- All DOE Office Websites (Extended Search)

Accommodations / Hours / Maps Accommodations / Hours / Maps Stanford Guest House This comfortable and convenient housing structure is located on SLAC's campus. Guests have access to in-room, high-speed Internet access, a fitness center, a 24-hour reception desk, laundry facilities, free parking, complimentary tea and coffee, and a 24-hour gift shop. The Guest House offers single as well as shared rooms, but all rooms have their own bathroom, and at very reasonable rates. All rooms are non-smoking only. Please reserve accommodations using their on-line form. If the Guest House is not available, additional accommodations may be made at local hotels/motels. For longer term visits, please contact the User Research Administration office. Gate Hours Maps & Directions SLAC Maps Directions to SLAC Security Gate 17

183

Combined Heating and Power Using Microturbines in a Major Urban Hotel  

SciTech Connect

This paper describes the results of a cooperative effort to install and operate a Cooling, Heating and Power (CHP) System at a major hotel in San Francisco, CA. The packaged CHP System integrated four microturbines, a double-effect absorption chiller, two fuel gas boosters, and the control hardware and software to ensure that the system operated predictably, reliably, and safely. The chiller was directly energized by the recycled hot exhaust from the microturbines, and could be configured to provide either chilled or hot water. As installed, the system was capable of providing up to 227 kW of net electrical power and 142 Refrigeration Tons (RT) of chilled water at a 59oF (15oC) ambient temperature. For the year, the CHP efficiency was 54 percent. Significant lessons learned from this test and verification project are discussed as well as measured performance and economic considerations.

Sweetser, Richard [Exergy Partners Corp.; Wagner, Timothy [United Technologies Research Center (UTRC); Leslie, Neil [Gas Technology Institute; Stovall, Therese K [ORNL

2009-01-01T23:59:59.000Z

184

Solar-cooling-system performance, Frenchman's Reef Hotel, St. Thomas, US Virgin Islands. Final report  

DOE Green Energy (OSTI)

The Solar Cooling System installed in the Frenchman's Reef Resort Hotel Test Site, St. Thomas, US Virgin Islands, used 956 Sunmaster Corporation evacuated glass tube collector modules which provide an effective solar collector aperture of 13,384 square feet. The system consists of the collectors, two 2500 gallon tanks, pumps, an Andover Controls Corporation computerized controller, a large solar optimized Carrier Corporation industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat. The system, its operation sequence, and performance are described.

Harber, H.

1981-09-25T23:59:59.000Z

185

Shared-savings cuts hotel's losses from EMS removal  

SciTech Connect

A shared-savings contract will minimize the Myrtle Beach, SC Downtown Holiday Inn's losses of replacing a poorly performing Energy Master energy-management system with Scientific Atlanta equipment. The contract with Energy Master Inc. (EMI), which saved Holiday Inn the $80,000 to $90,000 purchase price, also permitted removal (a year after installation) of the equipment when it failed to generate energy savings. A dispute between Associated Energy Consultants (AEC), which was to receive half the savings in exchange for arranging the equipment financing, is described. At $51,745, the 262-point Scientific Atlanta system should have a 1.7-year payback. The hotel's electric bills were $2000 a month lower during the first three months of operation. (DCK)

Galvin, C.

1982-11-08T23:59:59.000Z

186

Energy Integration Visualization Room (Fact Sheet)  

SciTech Connect

This two-page fact sheet describes the new Energy Integration Visualization Room in the ESIF and talks about some of the capabilities and unique visualization features of the the room.

Not Available

2012-08-01T23:59:59.000Z

187

The room noise criteria (RNC) metric.  

Science Conference Proceedings (OSTI)

The recent ANSI S12.2:2008 room noise criteria contains both a survey and an engineering method to specify room noise criteria. The methods use A?weighting and extended NC

2009-01-01T23:59:59.000Z

188

Room temperature nano- and microstructure photon detectors  

Science Conference Proceedings (OSTI)

The development of room temperature infrared (IR) detectors for wavelengths beyond NIR will open up many applications that are currently limited due to cooling requirements. Three approaches are discussed, which show promise for room temperature IR detection. ... Keywords: Infrared, PbS quantum dot, Room temperature detector, Split-off band, Tunneling quantum dot

A. G. U. Perera; P. V. V. Jayaweera; G. Ariyawansa; S. G. Matsik; K. Tennakone; M. Buchanan; H. C. Liu; X. H. Su; P. Bhattacharya

2009-03-01T23:59:59.000Z

189

FOIA Reading Room - privacy act  

NLE Websites -- All DOE Office Websites (Extended Search)

Reading Room - pricacy act Reading Room - pricacy act CH Frequently Requested Documents Under FOIA Administrative Electronic FOIA Form Privacy Act Advisory (Microsoft Word(tm) document) DOE-CH Government Purchase Card Cardholders: December 2012 CH Organizational Chart: Current Version Policies and Procedures - Office of Science (including Chicago Office) Office of Hearings and Appeals Decisions Department of Justice Cases and Legal Documents Department of Energy Directives DOE Office of Inspector General Reports Responses Under FOIA FY10 Management and Operating Contracts "FY2012 Laboratory Performance Report Cards" The following management and operating prime contracts under the jurisdiction of DOE-CH have been renewed and posted for your convenience. Modifications that change, delete, or add language to any portion of these contracts (referred to as "M" Mods) will be posted as expeditiously as possible after execution. It is at the discretion of the Contractors whether or not they include modifications that change the amount obligated by the Government. Ames Laboratory - Contract No. No.DE-AC02-07CH11358

190

Reading Room | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Reading Room | National Nuclear Security Administration Reading Room | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog The National Nuclear Security Administration Reading Room Home > About Us > Our Operations > Acquisition and Project Management > Major Contract Solicitations > Environmental Program Services Contract > Reading Room

191

Heating remote rooms in passive solar buildings  

DOE Green Energy (OSTI)

Remote rooms can be effectively heated by convection through a connecting doorway. A simple steady-state equation is developed for design purposes. Validation of a dynamic model is achieved using data obtained over a 13-day period. Dynamic effects are investigated using a simulation analysis for three different cases of driving temperature; the effect is to reduce the temperature difference between the driving room and the remote room compared to the steady-state model. For large temperature swings in the driving room a strategy which uses the intervening door in a diode mode is effective. The importance of heat-storing mass in the remote room is investigated.

Balcomb, J.D.

1981-01-01T23:59:59.000Z

192

Matchstick: A Room-to-Room Thermal Model for Predicting Indoor Temperature from Wireless Sensor Data  

E-Print Network (OSTI)

Matchstick: A Room-to-Room Thermal Model for Predicting Indoor Temperature from Wireless Sensor present a room-to-room thermal model used to accurately predict temperatures in residential buildings. We that our model can predict future indoor temperature trends with a 90th percentile aggregate error between

Hazas, Mike

193

Public Reading Room: Environmental Documents, Reports  

NLE Websites -- All DOE Office Websites (Extended Search)

Public Reading Room: Environmental Documents, Reports Public Reading Room: Environmental Documents, Reports Public Reading Room: Environmental Documents, Reports Environmental documents and reports are available online. Hard copies are available at the Laboratory's Public Reading Room in Pojoaque, New Mexico. Contact Environmental Communication & Public Involvement P.O. Box 1663 MS M996 Los Alamos, NM 87545 (505) 667-0216 Email Public Reading Room: Environmental Documents, Reports Online Annual Environmental Report Electronic Public Reading Room (EPRR) Plans, Procedures A listing of procedures available in the EPRR Hard copy Public Reading Room 94 Cities of Gold Road Pojoaque, NM Vie Screen reader users: click here for plain HTML Go to Google Maps Home 94 cities of gold Road, Pojoaque, NM Loading... Map Sat Ter Did you mean a different:

194

Train directions from Newark Airport to Nassau Inn or Palmer House Hotel Train is the most convenient way to get to Princeton from EWR. From the terminals at  

E-Print Network (OSTI)

Train directions from Newark Airport to Nassau Inn or Palmer House Hotel Train is the most://tinyurl.com/yc8g3rf or the Palmer House http://www.princeton.edu/palmerhouse/images/map.jpg Train directions from

195

Nuclear Energy Research Advisory Committee Meeting April 15-16, 2002, Marriott Crystal City Hotel, Arlington, Virginia  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

15-16, 2002, Marriott Crystal City Hotel, Arlington, Virginia 15-16, 2002, Marriott Crystal City Hotel, Arlington, Virginia NERAC members present: John Ahearne (Monday only) Robert Long Thomas Cochran Warren F. Miller, Jr. Joseph Comfort Benjamin F. Montoya Michael L. Corradini Sekazi Mtingwa Jose Luis Cortez Lura Powell Maureen S. Crandall Richard Reba (Tuesday only) Allen Croff Joy Rempe James Duderstadt (Chair) Daniel C. Sullivan (Monday morning only) Steve Fetter John Taylor Beverly Hartline Ashok Thadani (ad hoc; Monday only) Leslie Hartz Charles E. Till Andrew Klein Neil Todreas (Tuesday only) Dale Klein (Monday only) NERAC members absent: Marvin Fertel Allen Sessoms J. Bennett Johnston C. Bruce Tarter Linda C. Knight Joan Woodard Also present: Ralph Bennett, Director for Advanced Nuclear Energy, Idaho National Engineering and

196

Cost effective solar hot water system for Econo-Travel Motor Hotel located at Bluefield, West Virginia. Final report  

SciTech Connect

The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 3400 Cumberland Road, Bluefield, West Virginia. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately five (5) years instead of the 7.73 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. The success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

1979-07-01T23:59:59.000Z

197

Cost effective solar hot water system for Econo-Travel Motor Hotel located at Richmond, Virginia. Final report  

SciTech Connect

The final report is presented of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 5408 Williamsburg Road, Richmond, Virginia. The description of the system is given along with the final cost breakdown, expected performance data and expected payback time for the installed system is estimated to be approximately five (5) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. The success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

1979-09-01T23:59:59.000Z

198

Cost effective solar hot water system for Econo-Travel Motor Hotel located at Woodbrdge, VA. Final report  

SciTech Connect

The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 13317 Gordon Boulevard, Woodbridge, Virginia is given. The description of the system along with the final breakdown, performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 7.2 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

1978-11-01T23:59:59.000Z

199

Cost effective solar hot water system for Econo-Travel Motor Hotel located at Bluefield, West Virginia. Final report  

DOE Green Energy (OSTI)

The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 3400 Cumberland Road, Bluefield, West Virginia. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately five (5) years instead of the 7.73 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. The success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

Not Available

1979-07-01T23:59:59.000Z

200

Cost effective solar hot water system for Econo-Travel Motor Hotel located at Richmond, Virginia. Final report  

DOE Green Energy (OSTI)

The final report is presented of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 5408 Williamsburg Road, Richmond, Virginia. The description of the system is given along with the final cost breakdown, expected performance data and expected payback time for the installed system is estimated to be approximately five (5) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. The success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

Not Available

1979-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

NEPA Reading Room | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Reading Room | National Nuclear Security Administration Reading Room | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog NEPA Reading Room Home > About Us > Our Operations > NNSA Office of General Counsel > National Environmental Policy Act (NEPA) > NEPA Reading Room NEPA Reading Room Welcome to the National Nuclear Security Administration's NEPA Reading

202

Data for Room Fire Model Comparisons  

Science Conference Proceedings (OSTI)

... of the burn room; and, possibly, a load platform. ... by the use of the oxygen consumption principle ... be used to estimate the rate of energy production of ...

2004-10-05T23:59:59.000Z

203

NEPA Reading Room | National Nuclear Security Administration  

NLE Websites -- All DOE Office Websites (Extended Search)

NEPA Reading Room | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing...

204

NEPA Reading Room | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Reading Room | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our...

205

Test and Reconstruction of Air Conditioning System in a Hotel Lobby  

E-Print Network (OSTI)

Two air conditioning systems are equipped in a hotel lobby. It is found from the field test that the actual air rate is 40% and 16% of the nominal value, respectively, of the two systems, which is far lower than the design requirement. The air rate of the outlets varies greatly, and the coefficient of uniformity is 129.1% and 111.6% respectively of the two systems. Air distribution in the lobby is bad and thermal comfort is poor. Moreover, sharp reduction of return air makes portions of fresh air increase, which will lead to high energy consumption. Reconstruction is carried out to improve the thermal environment with the assistance of the CFD method. First, the original system is simulated by CFD method to verify the CFD method and propose modification suggestions. Then air conditioning load and air rate of the lobby is recalculated and duct redesigned. Simulation results show that the air distribution and thermal comfort of the improved scheme can meet the design requirement. The reconstructed system has been running for about two years and has shown good performance.

Wang, G.; Hu, Y.; Hu, S.; Chen, Q.

2006-01-01T23:59:59.000Z

206

Housing forms  

Science Conference Proceedings (OSTI)

Jan 18, 2002 ... TMS has contracted a block of rooms at the headquarters hotel, Sheraton Seattle Hotel & Towers, along with each of the hotels, and therefore ...

207

The Live Room: transducing resonant architectures  

Science Conference Proceedings (OSTI)

The Live Room was a temporary site-specific installation presented in building N51, room 117 on the MIT campus on 7 May 1998 and concluded on 10 June 1998. Using small acoustic-intensifying equipment which mounted directly to the structure of ...

Mark Bain

2003-08-01T23:59:59.000Z

208

Social media marketing in the hospitality industry: The role of benefits in increasing brand community participation and the impact of participation on consumer trust and commitment toward hotel and restaurant brands.  

E-Print Network (OSTI)

??Online community is an effective tool for building the relationship with consumers. Many hospitality firms (i.e., hotels and restaurants) have utilized online communities a new… (more)

Kang, Juhee

2011-01-01T23:59:59.000Z

209

DOE-ID FOIA Reading Room  

NLE Websites -- All DOE Office Websites (Extended Search)

Reading Room Reading Room READING ROOM Eectronic Freedom of Information Act, E-FOIA RECORDS UNDER THE E-FOIA The Electronic Freedom of Information Act Amendments of 1996 addresses the issues and procedural aspects of FOIA administration. The amendment: defines the term "record" as including "any information that would be an agency record subject to the requirements of the FOIA when maintained by an agency in any format, including an electronic format; addresses the form or format in which a requested record is disclosed providing the record is readily reproducible by the agency in the requestor's desired form or format; directs Federal agencies to maintain both conventional reading rooms and electronic reading rooms to meet FOIA responsibilities.

210

Los Alamos test-room results  

DOE Green Energy (OSTI)

Fourteen Los Alamos test rooms have been operated for several years; this paper covers operation during the winters of 1980-81 and 1981-82. Extensive data have been taken and computer analyzed to determine performance parameters such as efficiency, solar savings fraction, and comfort index. The rooms are directly comparable because each has the same net coefficient and solar collection area and thus the same load collector ratio. Configurations include direct gain, unvented Trombe walls, water walls, phase change walls, and two sunspace geometries. Strategies for reducing heat loss include selective surfaces, two brands of superglazing windows, a heat pipe system, and convection-suppression baffles. Significant differences in both backup heat and comfort are observed among the various rooms. The results are useful, not only for direct room-to-room comparisons, but also to provide data for validation of computer simulation programs.

McFarland, R.D.; Balcomb, J.D.

1982-01-01T23:59:59.000Z

211

Sorption of organic gases in residential rooms  

NLE Websites -- All DOE Office Websites (Extended Search)

residential rooms residential rooms Title Sorption of organic gases in residential rooms Publication Type Journal Article LBNL Report Number LBNL-59303 Year of Publication 2007 Authors Singer, Brett C., Alfred T. Hodgson, Toshifumi Hotchi, Katherine Y. Ming, Richard G. Sextro, Emily E. Wood, and Nancy J. Brown Journal Atmospheric Environment Volume 41 Start Page Chapter Pagination 3251-3265 Keywords adsorption, hazardous air pollutants, nerve agents, sink effect, volatile organic compounds Abstract Experiments were conducted to characterize organic gas sorption in residential rooms studied ''as-is'' with furnishings and material surfaces unaltered and in a furnished chamber designed to simulate a residential room. Results are presented for 10 rooms (five bedrooms, two bathrooms, a home office, and two multi-function spaces) and the chamber. Exposed materials were characterized and areas quantified. A mixture of volatile organic compounds (VOCs) was rapidly volatilized within each room as it was closed and sealed for a 5-h Adsorb phase; this was followed by 30-min Flush and 2-h closed-room Desorb phases. Included were alkane, aromatic, and oxygenated VOCs representing a range of ambient and indoor air pollutants. Three organophosphorus compounds served as surrogates for Sarin-like nerve agents. Measured gas-phase concentrations were fit to three variations of a mathematical model that considers sorption occurring at a surface sink and potentially a second, embedded sink. The 3-parameter sink-diffusion model provided acceptable fits for most compounds and the 4-parameter two-sink model provided acceptable fits for the others. Initial adsorption rates and sorptive partitioning increased with decreasing vapor pressure for the alkanes, aromatics and oxygenated VOCs. Best-fit sorption parameters obtained from experimental data from the chamber produced best-fit sorption parameters similar to those obtained from the residential rooms

212

Energy Consumption Measuring and Diagnostic Analysis of Air-conditioning Water System in a Hotel Building in Harbin  

E-Print Network (OSTI)

This paper introduces an air-conditioning water system in a hotel building in Harbin, finishes its air-conditioning energy consumption measurement in summer conditions, and presents an estimation index of performance of chiller, pump and motor. By means of testing data analysis, it is indicated that several problems such as unsuitable operation schedule of the chiller, low COP, irrational matching of pump and motor, unbalanced conditions of chilled water flow, and low working stability and efficiency ratio of the pump are existent. The paper presents suggestions for improvement with relevance based on the induction and analysis of system fault found in measurements.

Zhao, T.; Zhang, J.; Li, Y.

2006-01-01T23:59:59.000Z

213

An analysis of the performance of certification schemes in the hotel sector in terms of CO2 emissions reduction.  

E-Print Network (OSTI)

, Selina Hext, Freya Roe, Sarah Farmer, Gary Watson and Jason Maynard and Howard Carter on making it possible for me to continue my studies. Thank you for the incredible friendships I have made over the years in Cambridge which I hope will last... 8 xiii List of Publications Peer Reviewed Conference papers Houlihan Wiberg, A., Baker, N.V., 20 08a. 305: Certification in The Hotel Sector; Does It Actually Reduce Global CO2 Emissions? In: PLEA 2008 – 25th Conference on Passive...

Houlihan-Wiberg, Aoife Anne-marie

2010-07-18T23:59:59.000Z

214

Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

you need to mount the air conditioner at the narrow end of a long room, then look for a fan control known as "Power Thrust" or "Super Thrust" that sends the cooled air farther...

215

Design of the CTX diagnostics screen room  

DOE Green Energy (OSTI)

The design of a shielded enclosure (or screen room) to house data acquisition equipment in an area in which substantial, time varying magnetic fields are present and capable of producing significant interference is described.

Chandler, G.I. II

1981-01-01T23:59:59.000Z

216

Software Support during a Control Room Upgrade  

SciTech Connect

In 2004, after 14 years of accelerator operations and commissioning, Jefferson Lab renovated its main control room. Changes in technology and lessons learned during those 14 years drove the control room redesign in a new direction, one that optimizes workflow and makes critical information and controls available to everyone in the control room. Fundamental changes in a variety of software applications were required to facilitate the new operating paradigm. A critical component of the new control room design is a large-format video wall that is used to make a variety of operating information available to everyone in the room. Analog devices such as oscilloscopes and function generators are now displayed on the video wall through two crosspoint switchers: one for analog signals and another for video signals. A new software GUI replaces manual configuration of the oscilloscopes and function generators and helps automate setup. Monitoring screens, customized for the video wall, now make important operating information visible to everyone, not just a single operator. New alarm handler software gives any operator, on any workstation, access to all alarm handler functionality, and multiple users can now contribute to a single electronic logbook entry. To further support the shift to distributed access and control, many applications have been redesigned to run on servers instead of on individual workstations.

Michele Joyce; Michael Spata; Thomas Oren; Anthony Cuffe; Theo McGuckin; Isadoro Carlino; C. Higgins; Harry Fanning; Matthew Bickley; Brian Bevins

2005-09-21T23:59:59.000Z

217

Method of remotely constructing a room  

DOE Patents (OSTI)

The testing of nuclear devices of high explosive yield has required that cavities of relatively large size be provided at considerable distances below the surface of the earth for the pre-detonation emplacement of the device. The construction of an essentially watertight chamber or room in the cavity is generally required for the actual emplacement of the device. A method is described of constructing such a room deep within the earth by personnel at the surface. A dual wall bladder of a watertight, pliable fabric material is lowered down a shaft into a selected position. The bladder is filled with a concrete grout while a heavy fluid having essentially the same density as the grout is maintained on both sides of the bladder, to facilitate complete deployment of the bladder by the grout to form a room of desired configuration. (10 claims)

Michie, J.D.; De Hart, R.C.

1971-10-05T23:59:59.000Z

218

Carbon War Room | Open Energy Information  

Open Energy Info (EERE)

War Room War Room Jump to: navigation, search Name Carbon War Room Place Washington, DC Number of employees 1-10 Website http://www.carbonwarroom.com/ Coordinates 38.8951118°, -77.0363658° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":38.8951118,"lon":-77.0363658,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

219

A New Control Room for SLAC Accelerators  

SciTech Connect

We are planning to construct a new control room at SLAC to unify and improve the operation of the LCLS, SPEAR3, and FACET accelerator facilities, and to provide the space and flexibility needed to support the LCLS-II and proposed new test beam facilities. The existing control rooms for the linac and SPEAR3 have been upgraded in various ways over the last decade, but their basic features have remained unchanged. We propose to build a larger modern Accelerator Control Room (ACR) in the new Research Support Building (RSB) which is currently under construction at SLAC. Shifting the center of control for the accelerator facilities entails both technical and administrative challenges. In this paper, we describe the history, concept, and status of this project.

Erickson, Roger; Guerra, E.; Stanek, M.; Hoover, Z.Van; Warren, J.; /SLAC

2012-06-04T23:59:59.000Z

220

Matchstick: a room-to-room thermal model for predicting indoor temperature from wireless sensor data  

Science Conference Proceedings (OSTI)

In this paper we present a room-to-room thermal model used to accurately predict temperatures in residential buildings. We evaluate the accuracy of this model with ground truth data from four occupied family homes (two in the UK and two in the US). The ... Keywords: forced air, home automation, prediction, radiators, thermal modelling, underfloor heating

Carl Ellis; Mike Hazas; James Scott

2013-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Thermostat response and room temperature control  

Science Conference Proceedings (OSTI)

This article examines the impact to thermal comfort of the operation of the room thermostat. The topics of the article include types of thermostat response, reset response, proportional response, digital systems, system response, verification of building temperatures, thermal comfort analysis, and productivity costs of implementing mandated setpoints.

Int-Hout, D. (Carrier Corp., Syracuse, NY (United States))

1994-01-01T23:59:59.000Z

222

Texas Union Pizza Order Form ROOM RESERVED ______________________________________________________  

E-Print Network (OSTI)

#12;#12;Texas Union Pizza Order Form ROOM RESERVED: ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ Pick-up All orders are to be picked up at the Texas Union Hospitality Center desk in the south end West with the Texas Union Policies and Procedures. I understand that I will be held responsible for any debts incurred

Texas at Austin, University of

223

Advanced nuclear plant control room complex  

DOE Patents (OSTI)

An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.

Scarola, Kenneth (Windsor, CT); Jamison, David S. (Windsor, CT); Manazir, Richard M. (North Canton, CT); Rescorl, Robert L. (Vernon, CT); Harmon, Daryl L. (Enfield, CT)

1993-01-01T23:59:59.000Z

224

Operating Room Pooling and Parallel Surgery Processing Under Uncertainty  

Science Conference Proceedings (OSTI)

Operating room (OR) scheduling is an important operational problem for most hospitals. In this study, we present a novel two-stage stochastic mixed-integer programming model to minimize total expected operating cost given that scheduling decisions are ... Keywords: multiple operating rooms, operating room pooling, operating room scheduling, parallel surgery processing, two-stage stochastic mixed-integer programs

Sakine Batun; Brian T. Denton; Todd R. Huschka; Andrew J. Schaefer

2011-04-01T23:59:59.000Z

225

Disability Etiquette Guide The Basics  

E-Print Network (OSTI)

, child, applicant, etc. Has, uses, utilizes, etc. Wheelchair, autism, developmental delay, etc services Handicapped parking, hotel room, etc. Accessible parking, hotel room, etc. Client, consumer

Sibille, Etienne

226

Solar-cooling-system performance, Frenchman's Reef Hotel, St. Thomas, US Virgin Islands. Final report  

SciTech Connect

The Solar Cooling System installed in the Frenchman's Reef Resort Hotel Test Site, St. Thomas, US Virgin Islands, used 956 Sunmaster Corporation evacuated glass tube collector modules which provide an effective solar collector aperture of 13,384 square feet. The system consists of the collectors, two 2500 gallon tanks, pumps, an Andover Controls Corporation computerized controller, a large solar optimized Carrier Corporation industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat. The system, its operation sequence, and performance are described.

Harber, H.

1981-09-25T23:59:59.000Z

227

Priority coding for control room alarms  

SciTech Connect

Indicating the priority of a spatially fixed, activated alarm tile on an alarm tile array by a shape coding at the tile, and preferably using the same shape coding wherever the same alarm condition is indicated elsewhere in the control room. The status of an alarm tile can change automatically or by operator acknowledgement, but tones and/or flashing cues continue to provide status information to the operator.

Scarola, Kenneth (Windsor, CT); Jamison, David S. (Windsor, CT); Manazir, Richard M. (North Canton, CT); Rescorl, Robert L. (Vernon, CT); Harmon, Daryl L. (Enfield, CT)

1994-01-01T23:59:59.000Z

228

Federal Energy Management Program: Covered Product Category: Room Air  

NLE Websites -- All DOE Office Websites (Extended Search)

Room Air Conditioners to someone by E-mail Room Air Conditioners to someone by E-mail Share Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Facebook Tweet about Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Twitter Bookmark Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Google Bookmark Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Delicious Rank Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Digg Find More places to share Federal Energy Management Program: Covered Product Category: Room Air Conditioners on AddThis.com... Energy-Efficient Products Federal Requirements Covered Product Categories Product Designation Process

229

Release of DRAFT RFP Headquarters Reading Room Instructions/Guidelines  

NLE Websites -- All DOE Office Websites (Extended Search)

Release of DRAFT RFP Release of DRAFT RFP Headquarters Reading Room Instructions/Guidelines 1. Reading Room Points of Contact: 7/21 - 8/8, Mike Baehre, (202) 586-6575 8/9 - Close of Draft RFP, John Bernier, (202) 586-6416 Reading Room Availability: By Appointment - Reading Room will be available until DRAFT RFP Closes. Reading Room Hours: Morning, 9:00 a.m. - 11:30 a.m.; and Afternoon 1:00 p.m. - 3:30 p.m. Reading Room Will Accommodate: Up to 5-6 people 2. All personnel must: a. Sign-in b. Identify their Company or Firm they work for or are affiliated c. Indicate if they have a "Q" clearance 3. Personnel must stay in the Reading Room to view documents. The "A" corridor is inside a classified area and all visitors to the Reading Room must be escorted at all times.

230

Evaluation of Energy-Efficiency Standards for Room Air Conditioners...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy-Efficiency Standards for Room Air Conditioners in the US Title Evaluation of Energy-Efficiency Standards for Room Air Conditioners in the US Publication Type Journal Article...

231

UNIVERSITY OF MASSACHUSETTS AMHERST Engineering Laboratory Building, Box 32210  

E-Print Network (OSTI)

on the second floor of the hotel. One larger room and one smaller room were utilized through the course in Hotel Mercure near downtown Grenoble. Accommodations were offered in the same hotel where the conference

Massachusetts at Amherst, University of

232

Pre-validation of nuclear power plant control room design  

Science Conference Proceedings (OSTI)

Evaluation of the design of complex automation and control room systems is an essential phase in the design process in the nuclear field. For example, in order to meet the nuclear regulatory requirements, the new control room systems have to be evaluated ... Keywords: concept of operations, control room, pre-validation, verification & validation

Jari Laarni; Paula Savioja; Hannu Karvonen; Leena Norros

2011-07-01T23:59:59.000Z

233

Tritium Room Air Monitor Operating Experience Review  

SciTech Connect

Monitoring the breathing air in tritium facility rooms for airborne tritium is a radiological safety requirement and a best practice for personnel safety. Besides audible alarms for room evacuation, these monitors often send signals for process shutdown, ventilation isolation, and cleanup system actuation to mitigate releases and prevent tritium spread to the environment. Therefore, these monitors are important not only to personnel safety but also to public safety and environmental protection. This paper presents an operating experience review of tritium monitor performance on demand during small (1 mCi to 1 Ci) operational releases, and intentional airborne inroom tritium release tests. The tritium tests provide monitor operation data to allow calculation of a statistical estimate for the reliability of monitors annunciating in actual tritium gas airborne release situations. The data show a failure to operate rate of 3.5E-06/monitor-hr with an upper bound of 4.7E-06, a failure to alarm on demand rate of 1.4E-02/demand with an upper bound of 4.4E-02, and a spurious alarm rate of 0.1 to 0.2/monitor-yr.

L. C. Cadwallader; B. J. Denny

2008-09-01T23:59:59.000Z

234

NETL: NewsRoom - LabNotes  

NLE Websites -- All DOE Office Websites (Extended Search)

LabNotes LabNotes NewsRoom LabNotes January 2014 Chemical Looping 101: The Basics NETL's Chemical Looping Research Facilities Oxygen Carriers in Chemical Looping Combustion Chemical Looping Modeling and Simulation Research at NETL December 2013 Foamed Cement Can Seal Tricky Oil and Gas Wells November 2013 High-Performance Rechargeable Batteries May Help Keep the Lights On Rocks Demystified in Geomechanical Properties Lab October 2013 NETL's Morgantown Supercomputer Sets a High Bar for Energy Efficiency September 2013 NETL's Energy Data Exchange (EDX): Providing Access to Quality Energy Data Sorbents Capturing CO2 Will Make Power Plants Cleaner August 2013 Collaborative Technology Demonstrates Potential in Diabetes Testing Quantifying Uncertainty in Computer Model Predictions

235

Absorber Materials at Room and Cryogenic Temperatures  

Science Conference Proceedings (OSTI)

We recently reported on investigations of RF absorber materials at cryogenic temperatures conducted at Jefferson Laboratory (JLab). The work was initiated to find a replacement material for the 2 Kelvin low power waveguide Higher Order Mode (HOM) absorbers employed within the original cavity cryomodules of the Continuous Electron Beam Accelerator Facility (CEBAF). This effort eventually led to suitable candidates as reported in this paper. Furthermore, though constrained by small funds for labor and resources, we have analyzed a variety of lossy ceramic materials, several of which could be usable as HOM absorbers for both normal conducting and superconducting RF structures, e.g. as loads in cavity waveguides and beam tubes either at room or cryogenic temperatures and, depending on cooling measures, low to high operational power levels.

F. Marhauser, T.S. Elliott, A.T. Wu, E.P. Chojnacki, E. Savrun

2011-09-01T23:59:59.000Z

236

Room air monitor for radioactive aerosols  

DOE Patents (OSTI)

A housing assembly for use with a room air monitor for simultaneous collection and counting of suspended particles includes a casing containing a combination detector-preamplifier system at one end, a filter system at the other end, and an air flow system consisting of an air inlet formed in the casing between the detector-preamplifier system and the filter system and an air passageway extending from the air inlet through the casing and out the end opposite the detector-preamplifier combination. The filter system collects suspended particles transported directly through the housing by means of the air flow system, and these particles are detected and examined for radioactivity by the detector-pre The U.S. Government has rights in this invention pursuant to Contract No. DE-AC04-76DP03533 between the Department of Energy and Rockwell International Corporation.

Balmer, David K. (Broomfield, CO); Tyree, William H. (Boulder, CO)

1989-04-11T23:59:59.000Z

237

Room air monitor for radioactive aerosols  

DOE Patents (OSTI)

A housing assembly for use with a room air monitor for simultaneous collection and counting of suspended particles includes a casing containing a combination detector-preamplifier system at one end, a filter system at the other end, and an air flow system consisting of an air inlet formed in the casing between the detector-preamplifier system and the filter system and an air passageway extending from the air inlet through the casing and out the end opposite the detector-preamplifier combination. The filter system collects suspended particles transported directly through the housing by means of the air flow system, and these particles are detected and examined for radioactivity by the detector-preamplifier combination. 2 figs.

Balmer, D.K.; Tyree, W.H.

1987-03-23T23:59:59.000Z

238

A Meta-Analysis of Energy Savings from Lighting Controls in Commercial Buildings  

E-Print Network (OSTI)

Technologies Program: hotel guest room energy controls. Sanhotel and institutional bathroom lighting. [CEC] California Energy

Williams, Alison

2012-01-01T23:59:59.000Z

239

Electrorecovery of actinides at room temperature  

Science Conference Proceedings (OSTI)

There are a large number of purification and processing operations involving actinide species that rely on high-temperature molten salts as the solvent medium. One such application is the electrorefining of impure actinide metals to provide high purity material for subsequent applications. There are some drawbacks to the electrodeposition of actinides in molten salts including relatively low yields, lack of accurate potential control, maintaining efficiency in a highly corrosive environment, and failed runs. With these issues in mind we have been investigating the electrodeposition of actinide metals, mainly uranium, from room temperature ionic liquids (RTILs) and relatively high-boiling organic solvents. The RTILs we have focused on are comprised of 1,3-dialkylimidazolium or quaternary ammonium cations and mainly the {sup -}N(SO{sub 2}CF{sub 3}){sub 2} anion [bis(trif1uoromethylsulfonyl)imide {equivalent_to} {sup -}NTf{sub 2}]. These materials represent a class of solvents that possess great potential for use in applications employing electrochemical procedures. In order to ascertain the feasibility of using RTILs for bulk electrodeposition of actinide metals our research team has been exploring the electron transfer behavior of simple coordination complexes of uranium dissolved in the RTIL solutions. More recently we have begun some fundamental electrochemical studies on the behavior of uranium and plutonium complexes in the organic solvents N-methylpyrrolidone (NMP) and dimethylsulfoxide (DMSO). Our most recent results concerning electrodeposition will be presented in this account. The electrochemical behavior of U(IV) and U(III) species in RTILs and the relatively low vapor pressure solvents NMP and DMSO is described. These studies have been ongoing in our laboratory to uncover conditions that will lead to the successful bulk electrodeposition of actinide metals at a working electrode surface at room temperature or slightly elevated temperatures. The RTILs we have focused on thus far are based on 1,3-dialkylimidazolium or quaternary ammonium cations and {sup -}N(SO{sub 2}CF{sub 3}){sub 2} anions. Our results from XPS studies of e1ectrooxidized uranium metal surfaces indicate that uranium metal reacts with the anion from the RTIL, most likely through an initial f1uoride abstraction, forming decomposition products that inhibit the bulk electrodeposition of uranium metal. Similar results were found when the organic solvents were used with TBA[B(C{sub 6}F{sub 5}){sub 4}] as the supporting electrolyte, although the voltammetric data of uranium ions in these solutions is more encouraging in relation to electrodeposition of uranium metal. Preliminary results on the voltammetric behavior and bulk electrodeposition of plutonium species are also presented.

Stoll, Michael E [Los Alamos National Laboratory; Oldham, Warren J [Los Alamos National Laboratory; Costa, David A [Los Alamos National Laboratory

2008-01-01T23:59:59.000Z

240

Carbon promoted water electrolysis to produce hydrogen at room temperature.  

E-Print Network (OSTI)

??The objective of the work was to conduct water electrolysis at room temperature with reduced energy costs for hydrogen production. The electrochemical gasification of carbons… (more)

Ranganathan, Sukanya.

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Building Energy Software Tools Directory: Cold Room Calc  

NLE Websites -- All DOE Office Websites (Extended Search)

skills helpful but not required. Users More than 200 around the world. Audience Cold room design engineers, refrigeration equipment suppliers and contractors, owners of...

242

A holistic investigation of complexity sources in nuclear power plant control rooms  

E-Print Network (OSTI)

The nuclear power community in the United States is moving to modernize aging power plant control rooms as well as develop control rooms for new reactors. New generation control rooms, along with modernized control rooms, ...

Sasangohar, Farzan

2011-01-01T23:59:59.000Z

243

Differential impact of gas shortages and fuel-price increases on demand: the case of the hotel industry in New York State  

SciTech Connect

The authors assess the impact of the energy crisis on the lodging industry in New York (excluding New York City) by estimating the effects of two related, but not necessarily correlated, variables: gas shortages and energy price increases. Strong evidence supports the conclusion that energy shortages dampen hotel demand while price increases encourage international, intrastate, and interstate shifts in distance distributions of travel destinations as well as changes in number of trips and length of stay, resulting in a slight aggregate increase in demand. Recent industry data relating to occupancy rates and profitability seem to support this conclusion. 16 references, 2 tables.

Arbel, A. (Cornell Univ., Ithaca, NY); Ravid, A.

1983-04-01T23:59:59.000Z

244

Effective May 1, 2013, UT System rolled out the use of Concur for online booking of business travel. The University of Texas at Dallas faculty and staff can utilize one simple tool to book their flights, car rentals, and hotel stays.  

E-Print Network (OSTI)

. The University of Texas at Dallas faculty and staff can utilize one simple tool to book their flights, car rentals, and hotel stays. Advantages of Booking through Concur: Ease of booking all travel necessities Personal Credit Card (for hotels or non-direct bill car rentals) #12;#12;Travel Arrangers and Assistants

O'Toole, Alice J.

245

Simulation of a mannequin's thermal plume in a small room  

Science Conference Proceedings (OSTI)

Simulation results are presented for the buoyancy-driven flow in a small room containing a seated mannequin that is maintained at a constant temperature. The study was motivated, in part, by a published experimental study of the thermal plume around ... Keywords: Heated mannequin, Lattice Boltzmann method, Particle trajectories, Small room, Thermal plume

Xinli Jia; John B. Mclaughlin; Jos Derksen; Goodarz Ahmadi

2013-01-01T23:59:59.000Z

246

Physical Education Building Building Room Material Amount Percentage Priority Action  

E-Print Network (OSTI)

Physical Education Building Building Room Material Amount Percentage Priority Action Phys Ed Level Mechanical Insulation 250 LF 70.00 P6 Manage Phys Ed Level 1 East PE1H2 Pipe Fitting Mud 6 each 85.00 P5 #12;Building Room Material Amount Percentage Priority Action Phys Ed Level 2 West PE200 Pipe Fitting

Seldin, Jonathan P.

247

Service Building 4 Building Room Material Amount Percentage Priority Action  

E-Print Network (OSTI)

Service Building 4 Building Room Material Amount Percentage Priority Action Service Building 4 S160 65 sqft 15.00 P5 Manage S1J74 Friday, February 18, 2011 Page 1 of 2 #12;Building Room Material Amount Manage Mechanical Insulation 100 LF 55.00 P5 Manage Service Buliding 4 S16H6A Gypsum Wallboard Joint

Seldin, Jonathan P.

248

ENERGY STAR Qualified Room Air Conditioners | Data.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Room Air Conditioners Room Air Conditioners Consumer Data Apps Challenges Resources About Blogs Let's Talk Feedback Consumer You are here Data.gov » Communities » Consumer » Data ENERGY STAR Qualified Room Air Conditioners Dataset Summary Description Room Air Conditioners that have earned the ENERGY STAR are more efficient than standard models. ENERGY STAR is the trusted symbol for energy efficiency helping consumers save money and protect the environment through energy-efficient products and practices. More information on ENERGY STAR is available at www.energystar.gov. Tags {"Room Air Conditioners","Energy Star",products,"energy efficiency",efficient,"greenhouse gas emissions",climate,utility,utilities,household,savings,labels,partners,certification}

249

Building Energy Software Tools Directory: Room Air Conditioner Cost  

NLE Websites -- All DOE Office Websites (Extended Search)

Room Air Conditioner Cost Estimator Room Air Conditioner Cost Estimator Screen capture of Room Air Conditioner Cost Estimator The cost estimator compares high-efficiency room air conditioners to standard equipment in terms of life cycle cost. It provides an alternative to complicated building simulation models, while offering more precision than simplified estimating tools that are commonly available. The cost estimator assists decision-making regarding the purchase or replacement of room air conditioning equipment, by estimating a product�s lifetime energy cost savings at various efficiency levels. Screen Shots Keywords air conditioner, life-cycle cost, energy performance, residential buildings, energy savings Validation/Testing Internal reviews at Pacific Northwest National Laboratory.

250

Regulations establishing energy-conservation standards for new residential buildings  

SciTech Connect

The text of the California Administrative Code, Title 24, Part 6, Article 1 is presented. The energy conservation standards described apply to all new hotels, motels, apartment houses, lodging houses, dwellings, and other residential buildings which are heated or mechanically cooled. Standards for the building envelope, climate control systems and equipment, and water heating are included. (MCW)

Not Available

1980-02-01T23:59:59.000Z

251

SLAC National Accelerator Laboratory - Accommodations  

NLE Websites -- All DOE Office Websites (Extended Search)

4.3 14 Super 8 3200 El Camino Real, Palo Alto 650-493-9085 4.7 15 Hotel California 2431 Ash St., Palo Alto 650-322-7666 5.0 16 Coronet Motel 2455 El Camino Real, Palo Alto...

252

St. Johns River Water Management District 4049 Reid Street P.O. Box 1429 Palatka, FL 32178-1429  

E-Print Network (OSTI)

, ground or surface water and· water from public and private utilities. Additional information Irrigation withdrawn from ground or surface· water, from a private well or pump, or from a public or private utility or transient housing units, hotel and motel units, and public medians and rights-of-way. #12;St. Johns River

Watson, Craig A.

253

Morbidity and Mortality Weekly Report Weekly June 6, 2003 / Vol. 52 / No. 22  

E-Print Network (OSTI)

underscore the utility of these data for public- health decision making and the need for increased training,131 inspections; the majority (67.5%) occurred in pools for which no pool type (e.g., hotel/motel) was speci- fied

254

Foreign Fishery Developments Marine Angling in Australia  

E-Print Network (OSTI)

with bait, while those using spinning lures number 26 percent; 18 percent utilize pots and/or rings to take in 1983-84 to $2.2 billion (not included in this figure, however, was money spent for hotel/motel etc

255

Quest Hotel and Travel  

Science Conference Proceedings (OSTI)

... Waterfront. They serve BWI Airport/Amtrak, Penn Station Baltimore, Reagan National Airport and Dulles Airport. Airport ...

2013-02-21T23:59:59.000Z

256

Reiz Continental Hotel  

E-Print Network (OSTI)

WORKSHOP OBJECTIVES:> To proffer solution to the energy problems in Africa by providing a forum for exchange of ideas by major stake holders.:> To address important aspects of the implementation of Renewable Energy Programmes in Africa.:> Explore emerging policy issues, regulations and implementation frameworks for the development of renewable energy and energy efficiency markets in Africa.:> Public awareness creation among poiicy makers, investors and the generai public on the potentials of renewable energy and energy efficiency in Africa SCOPE OF WORKSHOP:> State-of-the-art lectures to be delivered by seasoned experts in renewable energy in such areas as: • Sea Water desalination • Solar drying (food & cash crops,

University Nigeria; Sustalnable Economie

2010-01-01T23:59:59.000Z

257

Energy Consumption Estimation for Room Air-conditioners Using Room Temperature Simulation with One-Minute Intervals  

E-Print Network (OSTI)

For the purpose of developing optimized control algorithm for room air-conditioners to ensure their energy efficiency, a short time interval (i.e., one minute) simulation of building thermal performance is necessary because the sampling time interval for room air-conditioner control is one minute in general. This paper studies the short-time interval room air temperature simulation method using the response factor method. Using the simulated room air temperature, an air-conditioner's running time can be known so that its energy consumption can be estimated accurately. In order to verify the simulation accuracy, an actual room equipped with a gas-engine heat pump (GHP) air-conditioning system is studied by both simulation and measurement. The cooling amount produced by the GHP is calculated using measured refrigerant pressure and temperature at condenser and evaporator respectively. The Root Mean Square Error (RMSE) between measured cooling amount and simulated cooling load is 18.9 percent of the average measured value. The profile of simulated room air temperature in both air-conditioned daytime and nighttime without air-conditioning can match the measured room air temperature. With respect to the estimated energy consumption, the profile of simulated energy consumption can match the measured data. The simulation accuracy of room air temperature and energy consumption during the air-conditioner start-up period is not good and needs to be improved in future research. But in general, the verification shows that this energy consumption simulation method is acceptable for evaluating the energy performance of a room air-conditioner, and can also be a useful tool for commissioning room air-conditioners.

Wang, F.; Yoshida, H.; Matsumoto, K.

2006-01-01T23:59:59.000Z

258

Solar hot water pays off for commercial enterprises  

SciTech Connect

Two solar water heating systems in Florida are described. One system supplies a motel for guest rooms, laundry, and kitchen. The other system serves a coin-operated laundry. (WDM)

Jones, H.

1976-05-01T23:59:59.000Z

259

Quantitative room-temperature mineralization of airborne formaldehyde using  

NLE Websites -- All DOE Office Websites (Extended Search)

Quantitative room-temperature mineralization of airborne formaldehyde using Quantitative room-temperature mineralization of airborne formaldehyde using manganese oxide catalysts Title Quantitative room-temperature mineralization of airborne formaldehyde using manganese oxide catalysts Publication Type Journal Article Year of Publication 2011 Authors Sidheswaran, Meera A., Hugo Destaillats, Douglas P. Sullivan, Joern Larsen, and William J. Fisk Journal Applied Catalysis B - Environmental Issue 107 Pagination 34-41 Date Published 2011 Keywords commercial building ventilation & indoor environmental quality group, commercial building ventilation and indoor environmental quality group, energy analysis and environmental impacts department, indoor environment department, indoor environment group DOI 10.1016/j.apcatb.2011.06.032 Attachment Size

260

Monitoring radioactive xenon gas in room air using activated charcoal  

SciTech Connect

A method for monitoring room air for radioactive xenon gas is described. It uses activated charcoal vials, a vacuum source and a well-type scintillation counter. The method may be adapted for detection and identification of any radioactive gas excluding those with ultra-short half-lives. Sampling room air during xenon-133 ({sup 133}Xe) ventilation lung studies was performed using this technique. The results show that low concentrations of {sup 133}Xe in room air can be reliably detected and that staff exposure to {sup 133}Xe at this institution was within ICRP recommendations.

Langford, J.; Thompson, G. (Princess Margaret Hospital for Children, Perth (Australia) Sir Charles Gairdner Hospital, Perth (Australia))

1990-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

WIPP Reaches Milestone „ First Disposal Room Filled  

NLE Websites -- All DOE Office Websites (Extended Search)

WIPP Reaches Milestone - First Disposal Room Filled CARLSBAD, N.M., September 4, 2001 - The U.S. Department of Energy's (DOE) Carlsbad Field Office today announced that Room 7 of Panel 1 at the Waste Isolation Pilot Plant (WIPP), the first underground room used for disposal operations, has been filled to capacity with transuranic waste. The milestone was reached at about 3:30 p.m. on August 24, as Waste Handling personnel emplaced a shipment of waste from the Idaho National Engineering and Environmental Laboratory. On August 25, Underground Operations personnel completed installation of a chain link mesh barrier and cloth drape across the entrance to the room to officially declare the area "closed." The first shipment of waste, which came

262

Dorm Room Idea Now Revolutionizing Energy | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Dorm Room Idea Now Revolutionizing Energy Dorm Room Idea Now Revolutionizing Energy Dorm Room Idea Now Revolutionizing Energy April 16, 2010 - 11:07am Addthis Joshua DeLung What does this project do? Princeton Power Systems is currently installing a 200-kW solar array and advanced battery system on company grounds to provide clean power to its building and to showcase advancements in renewable energy technology to businesses, municipalities and utilities that may be curious about renewable energy projects. While many college students might spend their time playing Ultimate Frisbee or enjoying the nightlife, Darren Hammell and several other Princeton University classmates transformed an idea fostered in a dorm room into one of the fastest-growing businesses in the energy industry, creating jobs and

263

Virtual Reading Room prior to 2000 | National Nuclear Security  

National Nuclear Security Administration (NNSA)

prior to 2000 | National Nuclear Security prior to 2000 | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Virtual Reading Room prior to 2000 Home > About Us > Our Operations > NNSA Office of General Counsel > Freedom of Information Act (FOIA) > Virtual Reading Room prior to 2000 Virtual Reading Room prior to 2000 Printer-friendly version Printer-friendly version

264

Control and Room Temperature Optimization of Energy Efficient Buildings  

SciTech Connect

The building sector consumes a large part of the energy used in the United States and is responsible for nearly 40% of greenhouse gas emissions. It is therefore economically and environmentally important to reduce the building energy consumption to realize massive energy savings. In this paper, a method to control room temperature in buildings is proposed. The approach is based on a distributed parameter model represented by a three dimensional (3D) heat equation in a room with heater/cooler located at ceiling. The latter is resolved using finite element methods, and results in a model for room temperature with thousands of states. The latter is not amenable to control design. A reduced order model of only few states is then derived using Proper Orthogonal Decomposition (POD). A Linear Quadratic Regulator (LQR) is computed based on the reduced model, and applied to the full order model to control room temperature.

Djouadi, Seddik M [ORNL; Kuruganti, Phani Teja [ORNL

2012-01-01T23:59:59.000Z

265

Covered Product Category: Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Room Air Conditioners Room Air Conditioners Covered Product Category: Room Air Conditioners October 7, 2013 - 10:40am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including room air conditioners, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

266

Demonstration of Intelligent Control and Fan Improvements in Computer Room  

NLE Websites -- All DOE Office Websites (Extended Search)

Demonstration of Intelligent Control and Fan Improvements in Computer Room Demonstration of Intelligent Control and Fan Improvements in Computer Room Air Handlers Title Demonstration of Intelligent Control and Fan Improvements in Computer Room Air Handlers Publication Type Report Refereed Designation Unknown LBNL Report Number LBNL-6007E Year of Publication 2012 Authors Coles, Henry C., Steve E. Greenberg, and Corrine Vita Document Number LBNL-6007E Date Published 12/2012 Publisher Lawrence Berkeley National Laboratory City Berkeley, CA Keywords air distribution, building technology and urban systems department, computer room air handler, crah control, data center, data center crah, ec fan, ecm, ecm fan, fan speed control, high tech and industrial systems group, plug fan, variable frequency drive, vfd, wireless control Abstract

267

Covered Product Category: Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Room Air Conditioners Room Air Conditioners Covered Product Category: Room Air Conditioners October 7, 2013 - 10:40am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including room air conditioners, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

268

MODELING OF HEAT TRANSFER IN ROOMS IN THE MODELICA  

NLE Websites -- All DOE Office Websites (Extended Search)

MODELING MODELING OF HEAT TRANSFER IN ROOMS IN THE MODELICA "BUILDINGS" LIBRARY Michael Wetter, Wangda Zuo, Thierry Stephane Nouidui Simulation Research Group, Building Technologies Department Environmental Energy Technologies Division, Lawrence Berkeley National Laboratory Berkeley, CA 94720, USA ABSTRACT This paper describes the implementation of the room heat transfer model in the free open-source Modelica "Buildings" library. The model can be used as a single room or to compose a multizone building model. We discuss how the model is de- composed into submodels for the individual heat transfer phenomena. We also discuss the main physical assumptions. The room model can be parameterized to use di↵erent modeling assump- tions, leading to linear or non-linear di↵erential algebraic systems of equations. We present nu- merical experiments that show

269

Press Room - U.S. Energy Information Administration (EIA)  

U.S. Energy Information Administration (EIA)

Search EIA.gov. A-Z Index; A-Z Index A B C D E F G H I J K L M N O P Q R S T U V W XYZ. Press Room. Glossary ...

270

Design of a multisystem remote maintenance control room  

SciTech Connect

The Remote Systems Development Section of the Consolidated Fuel Reprocessing Program at the Oak Ridge National Laboratory (ORNL) and Japan's Power Reactor and Nuclear Fuel Development Corporation (PNC) recently collaborated in the development of a control room concept for remote operations. This report describes design methods and the resulting control room concept. The design project included five stages. The first was compilation of a complete function list; functions are tasks performed by operators in the control room while operating equipment located in the remote area. The second step was organization of the function list into ''function groups;'' function groups are sets of functions that operate one piece of equipment. The third stage was determination of crew size and requirements for supervision. The fourth stage was development of conceptual designs of displays and controls. The fifth stage was development of plans for placement of crew stations within the control room. 5 figs., 1 tab.

Draper, J.V.; Handel, S.J.; Kring, C.T.; Kawatsuma, S.

1988-01-01T23:59:59.000Z

271

Jeremiah Holzbauer Michigan State University Bldg. 401, Room...  

NLE Websites -- All DOE Office Websites (Extended Search)

Jeremiah Holzbauer Michigan State University Bldg. 401, Room B-4100 Wednesday February 8, 1:30 pm Host: Ali Nassiri The Beams and Applications Seminar Series For more information...

272

Grid Support for Collaborative Control Room in Fusion Science  

Science Conference Proceedings (OSTI)

The National Fusion Collaboratory project seeks to enable fusion scientists to exploit Grid capabilities in support of experimental science. To this end we are exploring the concept of a collaborative control room that harnesses Grid and collaborative ...

K. Keahey; M. E. Papka; Q. Peng; D. Schissel; G. Abla; T. Araki; J. Burruss; E. Feibush; P. Lane; S. Klasky; T. Leggett; D. Mccune; L. Randerson

2005-10-01T23:59:59.000Z

273

NETL: NewsRoom - This Week at NETL  

NLE Websites -- All DOE Office Websites (Extended Search)

NewsRoom This Week at NETL 2013 October September August July October 15, 2013 October 7, 2013 September 30, 2013 September 23, 2013 September 16, 2013 September 9, 2013 September...

274

Second Panel of Disposal Rooms Completed in WIPP Underground  

NLE Websites -- All DOE Office Websites (Extended Search)

Isolation Pilot Plant P.O. Box 3090 Carlsbad, New Mexico 88221 DOENews -2- Underground waste disposal panels are arranged in parallel sets of seven rooms each. Each set of seven...

275

Variable Speed Fan Retrofits for Computer Room Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

Variable-Speed Fan Retrofits for Computer-Room Air Conditioners Prepared for the U.S. Department of Energy Federal Energy Management Program Technology Case Study Bulletin By...

276

Near room temperature lithographically processed metal-oxide transistors  

E-Print Network (OSTI)

A fully lithographic process at near-room-temperature was developed for the purpose of fabricating transistors based on metal-oxide channel materials. The combination of indium tin oxide (ITO) as the source/drain electrodes, ...

Tang, Hui, M. Eng. Massachusetts Institute of Technology

2008-01-01T23:59:59.000Z

277

Five ENERGY STAR Room Air Conditioners Fail Testing  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy's Office of Enforcement announced today that DOE testing has identified five Friedrich room air conditioners that do not meet the ENERGY STAR Program’s energy...

278

Virtual Reading Room after to 2000 | National Nuclear Security  

National Nuclear Security Administration (NNSA)

after to 2000 | National Nuclear Security after to 2000 | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Virtual Reading Room after to 2000 Home > About Us > Our Operations > NNSA Office of General Counsel > Freedom of Information Act (FOIA) > Virtual Reading Room after to 2000 Virtual Reading Room after to 2000 Printer-friendly version Printer-friendly version

279

Tertiary Containment in a Multi-Room Tritium Facility  

SciTech Connect

An experimental system to provide tertiary containment at Mound has been upgraded to support a new multi-room tritium handling facility. This system is used to remove tritium from room air in the event of primary (process) and secondary (glovebox) containment failure. The upgraded system includes a faster response time, piping and valves that are more leaktight, and a new control panel that better indicates the system status and operating conditions.

Kent, L. R.

1985-04-01T23:59:59.000Z

280

How (and where) to book rooms This guide will tell you how and where to book rooms and spaces in the Students'  

E-Print Network (OSTI)

How (and where) to book rooms This guide will tell you how and where to book rooms and spaces are completely FREE to use for societies and committees. All you need is a current Room Booking Card to show per society/committee). If you want a valid room booking card for the academic year 12/13 you MUST

Dixon, Peter

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

ENERGY STAR  

NLE Websites -- All DOE Office Websites (Extended Search)

STAR certified buildings > photo of a room in the W Hotel, San Francisco, CA W HOTEL, San Francisco, Calif. In 2007, hotel employees submitted a petition asking management to...

282

Using a Research Simulator for Validating Control Room Modernization Concepts  

SciTech Connect

The Light Water Reactor Sustainability Program is a research, development, and deployment program sponsored by the United States Department of Energy. The program is operated in close collaboration with industry research and development programs to provide the technical foundations for licensing and managing the long-term, safe, and economical operation of nuclear power plants that are currently in operation. Advanced instrumentation and control (I&C) technologies are needed to support the continued safe and reliable production of power from nuclear energy systems during sustained periods of operation up to and beyond their expected licensed lifetime. This requires that new capabilities to achieve process control be developed and eventually implemented in existing nuclear control rooms. It also requires that approaches be developed and proven to achieve sustainability of I&C systems throughout the period of extended operation. Idaho National Laboratory (INL) is working closely with nuclear utilities to develop technologies and solutions to help ensure the safe life extension of current reactors. One of the main areas of focus is control room modernization. Current analog control rooms are growing obsolete, and it is difficult for utilities to maintain them. Using its reconfigurable control room simulator adapted from a training simulator, INL serves as a neutral test bed for implementing new control room system technologies and assisting in control room modernization efforts across.

Ronald L. Boring; Vivek Agarwal; Julius J. Persensky; Jeffrey C. Joe

2012-05-01T23:59:59.000Z

283

Transactions of the twenty-third water reactor safety information meeting to be held at Bethesda Marriott Hotel, Bethesda, Maryland, October 23--25, 1995  

SciTech Connect

This report contains summaries of papers on reactor safety research to be presented at the 23rd Water Reactor Safety Information Meeting at the Bethesda Marriott Hotel, Bethesda, Maryland, October 23--25, 1995. The summaries briefly describe the programs and results of nuclear safety research sponsored by the Office of Nuclear Regulatory, Research, US NRC. Summaries of invited papers concerning nuclear safety issues from US government laboratories, the electric utilities, the nuclear industry, and from foreign governments and industry are also included. The summaries have been compiled in one report to provide a basis for meaningful discussion and information exchange during the course of the meeting and are given in the order of their presentation in each session.

Monteleone, S. [comp.

1995-09-01T23:59:59.000Z

284

ARIEL: automatic wi-fi based room fingerprinting for indoor localization  

Science Conference Proceedings (OSTI)

People spend the majority of their time indoors, and human indoor activities are strongly correlated with the rooms they are in. Room localization, which identifies the room a person or mobile phone is in, provides a powerful tool for characterizing ...

Yifei Jiang; Xin Pan; Kun Li; Qin Lv; Robert P. Dick; Michael Hannigan; Li Shang

2012-09-01T23:59:59.000Z

285

Charles Motel & Bathhouse Pool & Spa Low Temperature Geothermal...  

Open Energy Info (EERE)

Generation 1.00x109 Btuyr 0.30 GWhyr Delat T 5.00 F Load Factor 0.38 Contact Kathy Clark; 505-894-7154 References Oregon Institute of Technology's Geo-Heat Center1 Charles...

286

Pilot Study: Measurement of Room Illuminance to Assess Automatic Brightness  

NLE Websites -- All DOE Office Websites (Extended Search)

Study: Measurement of Room Illuminance to Assess Automatic Brightness Study: Measurement of Room Illuminance to Assess Automatic Brightness Control in Televisions Title Pilot Study: Measurement of Room Illuminance to Assess Automatic Brightness Control in Televisions Publication Type Conference Proceedings Year of Publication 2012 Authors Greenblatt, Jeffery B., Mia Forbes Pirie, Louis-Benoit Desroches, Sally M. Donovan, Clancy Donnelly, Craig Billingsley, and Chris Calwell Pagination 13 Date Published August 12 Conference Location Berkeley Abstract Automatic brightness control (ABC) is an increasingly common feature found in newtelevisions (TVs) and computer monitors. ABC is intended to adjust TV screen brightness(luminance) according to the ambient light level (room illuminance). When implementedcorrectly, this can both reduce energy consumption and improve viewing quality. The currentENERGY STAR test procedure provides for a more favorable energy use rating for TVs withABC, by measuring power consumption at two light levels (0 and 300 lux) and reporting aweighted-average energy use. However, this and other studies suggest that these levels are notrepresentative of actual TV viewing conditions.As there were currently only limited data available concerning room illuminance, weundertook a small pilot study in 2011 to begin to answer two key questions: 1. To what extent doroom illuminance levels vary depending on the location of measurement (e.g., center of theroom, on the couch, or at the TV)? 2. What room illuminance conditions are prevalent whenpeople watch TV?We measured room illuminance in the homes of nine volunteers in California andColorado to begin addressing the above two questions. Although the study had the usualdrawbacks of a pilot (limited sample size, time duration, etc.), it has, nonetheless, yielded usefulresults. The study shows definitively that there is large variability between measurements madeat different locations in the room and, therefore, that location of room illuminance measurementsis critical. Moreover, the majority (over 75%) of TV viewing occurred at illuminance levels ofless than 50 lux (though measurements of up to several hundred lux were also recorded), a resultthat was consistent with subsequent larger-scale studies. This type of information can helpdetermine how ABC-enabled TVs should be tested to best represent actual viewing conditions.

287

When Emergency Rooms Close: Ambulance Diversion in the West San Fernando Valley  

E-Print Network (OSTI)

Multiple critical patients APP: When Emergency Rooms Closeparamedics sit in a crowded emergency room. 16 These waitsS. Chan. “The effect of emergency department crowding on

Natasha Mihal; Renee Moilanen

2005-01-01T23:59:59.000Z

288

Community Activity Room (CAR) Painter, Version 4.0  

Science Conference Proceedings (OSTI)

The CAR V4 software visualizes transmission congestion and grid reliability in both a two-dimensional painting and a three-dimension rendering of walls enclosing a Community Activity Room. EPRI developed the concept of the Community Activity Room in the spring of 2002. It was implemented in the CAR Painter software. A demonstration software was issued in September 2002. In April, 2004, version 2.0 was released with many features added to the CAR Painter, including a 3-D visualization module. Version 3.0 ...

2005-11-30T23:59:59.000Z

289

Lighting program at L. A. 's Westin leaves no room for energy waste  

SciTech Connect

This paper describes how one of the largest hotels in the Western US achieved dramatic reductions in energy consumption with a fluorescent energy saving device and a facility-wide energy management program. The Westin Bonaventure in Los Angeles has been able to reduce their energy consumption over 30 percent on 600 or more eight-foot fluorescent fixtures throughout the property. In addition, there were hidden savings like extended ballast life and reduced air-conditioning expenses due to cooler operation of the lamps. Other aspects of the hotel's energy management program include an energy management system for heating, ventilating and air-conditioning (HVAC) of public areas, flow restrictors on shower heads and faucets, the use of energy saving lamps and the extensive use of glass to take advantage of the sun for heating and lighting.

1984-04-01T23:59:59.000Z

290

Patient/Family Waiting Room Analysis For Susquehanna Health's  

E-Print Network (OSTI)

for WRMC against others in the industry, the team found that the industry average cost was $1.57 per square objectives included measuring the square footage of the waiting rooms, researching utility costs, utilization foot. This value is less than the WRMC maintenance costs, so the team provided recommendations

Demirel, Melik C.

291

Information Foraging in Nuclear Power Plant Control Rooms  

SciTech Connect

nformation foraging theory articulates the role of the human as an 'informavore' that seeks information and follows optimal foraging strategies (i.e., the 'information scent') to find meaningful information. This paper briefly reviews the findings from information foraging theory outside the nuclear domain and then discusses the types of information foraging strategies operators employ for normal and off-normal operations in the control room. For example, operators may employ a predatory 'wolf' strategy of hunting for information in the face of a plant upset. However, during routine operations, the operators may employ a trapping 'spider' strategy of waiting for relevant indicators to appear. This delineation corresponds to information pull and push strategies, respectively. No studies have been conducted to determine explicitly the characteristics of a control room interface that is optimized for both push and pull information foraging strategies, nor has there been empirical work to validate operator performance when transitioning between push and pull strategies. This paper explores examples of control room operators as wolves vs. spiders and con- cludes by proposing a set of research questions to investigate information foraging in control room settings.

R.L. Boring

2011-09-01T23:59:59.000Z

292

Measurement of Absorption in Rooms with Sound Absorbing Ceilings  

Science Conference Proceedings (OSTI)

Serious difficulties have been encountered in attempts to measure the absorption coefficients of sound absorbing ceilings in large offices. An analysis of the sound field is made and it is concluded (1) that the reverberation time formula is usually invalid if the absorption is concentrated on one surface of the room

J. R. Power

1938-01-01T23:59:59.000Z

293

Science Career & Cooperative Education Burke Science Building Room 127  

E-Print Network (OSTI)

Science Career & Cooperative Education Burke Science Building Room 127 www.science event. Visit the SCCE website to find event dates and details: www.science.mcmaster.ca/scce Attend a Co visit: www.science.mcmaster.ca/scce Enroll in SCIENCE 2C00 to learn the skills for career success

Hitchcock, Adam P.

294

Press Room - Testimony - U.S. Energy Information Administration (EIA)  

U.S. Energy Information Administration (EIA)

A B C D E F G H I J K L M N O P Q R S T U V W XYZ. Press Room. ... Subcommittee on Energy Committee on Science, Space and Technology U.S. House of Representatives ...

295

FUEL HANDLING FACILITY BACKUP CENTRAL COMMUNICATIONS ROOM SPACE REQUIREMENTS CALCULATION  

SciTech Connect

The purpose of the Fuel Handling Facility Backup Central Communications Room Space Requirements Calculation is to determine a preliminary estimate of the space required to house the backup central communications room in the Fuel Handling Facility (FHF). This room provides backup communications capability to the primary communication systems located in the Central Control Center Facility. This calculation will help guide FHF designers in allocating adequate space for communications system equipment in the FHF. This is a preliminary calculation determining preliminary estimates based on the assumptions listed in Section 4. As such, there are currently no limitations on the use of this preliminary calculation. The calculations contained in this document were developed by Design and Engineering and are intended solely for the use of Design and Engineering in its work regarding the FHF Backup Central Communications Room Space Requirements. Yucca Mountain Project personnel from Design and Engineering should be consulted before the use of the calculations for purposes other than those stated herein or use by individuals other than authorized personnel in Design and Engineering.

B. SZALEWSKI

2005-03-22T23:59:59.000Z

296

China Energy Efficiency Round Robin Testing Results for Room  

E-Print Network (OSTI)

LBNL-3502E China Energy Efficiency Round Robin Testing Results for Room Air Conditioners Nan Zhou Round Robin Testing Results and Analysis by China National Institute of Standardization..................................................................................................................... 1 I.1.1 China's Energy Constraint Problem and the Need to Improve the Energy Efficiency of Energy

297

The Influence of Operating Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner  

E-Print Network (OSTI)

A field investigation was carried out in an office building of Changsha city in winter and summer, the influence of different running modes, curtain styles and room temperature set point on energy consumption of room air conditioner (RAC) was studied. The results show that: In summer automatic speed mode consumes the least refrigerating energy in different running modes, compared with low speed and high speed modes, it can conserve energy for 27.3% and 15.8%, respectively. In the same running mode, setting outer curtain can conserve energy for 40.9% and 20.4% compared with no curtain and inner curtain states, respectively. In winter high speed mode is the most efficient for saving energy which can decrease 40.3% and 30.9% compared with low speed and automatic speed modes. In the same running mode, setting inner curtain state makes the least heating energy consumption in cloudy day, about 10.8% and 2.7% less than no curtain and outer curtain states. However, it is not obvious when the day is fine. The heating energy consumption decreases as room temperature set point falls, compared with the energy consumption at 20.5 C and 19.5 C, it is decreases for 34.1% and17.0 % at 18.5 C, respectively. All the results will be the reference of environment design and control for air conditioning room.

Yu, J.; Yang, C.; Guo, R.; Wu, D.; Chen, H.

2006-01-01T23:59:59.000Z

298

Airflow Simulation and Energy Analysis in Ventilated Room with a New Type of Air Conditioning  

E-Print Network (OSTI)

Airflow simulation in one ventilated room with radiant heating and natural ventilation has been carried out. Three cases are compared: the closed room, the room with full openings, and the room with small openings. The radiator heating room with small openings is recommended. The airflow and thermal comfort are discussed for the last case. It is suitable for two kinds of civil buildings, housing buildings and office buildings, which take up the largest part of all functional buildings.

Liu, D.; Tang, G.; Zhao, F.

2006-01-01T23:59:59.000Z

299

Press Room - Radio - U.S. Energy Information Administration (EIA)  

U.S. Energy Information Administration (EIA) Indexed Site

Press Room Press Room Glossary › FAQS › Overview Press Releases Testimony Presentations Radio Events Radio Spots Ready-to-broadcast news stories. Transcripts provided so radio spots can be re-recorded in whole or in part. Residential heating oil prices virtually unchanged mp3 Date: December 18, 2013 Description: The average retail price for home heating oil fell 4-tenths of a penny from a week ago to $3.95 per gallon. That's down 8-tenths of a penny from a year ago, based on the residential heating fuel survey by the U.S. Energy Information Administration. Heating oil prices in the New England region rose 3.92 per gallon, up 3-tenths of a cent from last week, and up 3 cents from a year ago. Contact/Author: Amerine Woodyard, 202-586-1256 Transcript: http://www.eia.gov/radio/transcript/heating_oil_prices_12182013.pdf

300

List of Room Air Conditioners Incentives | Open Energy Information  

Open Energy Info (EERE)

Conditioners Incentives Conditioners Incentives Jump to: navigation, search The following contains the list of 112 Room Air Conditioners Incentives. CSV (rows 1 - 112) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio - Commercial New Construction Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Industrial Local Government Municipal Utility Nonprofit Schools State Government Central Air conditioners Chillers Comprehensive Measures/Whole Building Custom/Others pending approval Energy Mgmt. Systems/Building Controls Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Motors Water Heaters Commercial Cooking Equipment Commercial Refrigeration Equipment Room Air Conditioners Yes Alexandria Light and Power - Residential Energy Efficiency Rebate Program (Minnesota) Utility Rebate Program Minnesota Residential Central Air conditioners

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Press Room - U.S. Energy Information Administration (EIA)  

U.S. Energy Information Administration (EIA) Indexed Site

Press Room Press Room Glossary › FAQS › Overview Press Releases Testimony Presentations Radio Events Press Releases State Energy Profiles enhanced and renewables sections added December 19, 2013 Growing oil and natural gas production continues to reshape the U.S. energy economy December 16, 2013 MEDIA ADVISORY: EIA to Release Updated Energy Forecasts to 2040 December 4, 2013 EIA initiates new monthly Drilling Productivity Report October 22, 2013 More press releases... Congressional Testimony U.S. petroleum supply system pdf Subject: EIA, Petroleum Presented by: Adam Sieminski, Administrator Presented to: Committee on Energy and Natural Resources U.S. Senate Washington, DC-July 16, 2013 Renewable Fuel Standard (RFS) program pdf Subject: EIA, Renewable, Forecasts Presented by: Adam Sieminski, Administrator

302

Sorption of organic gases in a furnished room  

NLE Websites -- All DOE Office Websites (Extended Search)

a furnished room a furnished room Title Sorption of organic gases in a furnished room Publication Type Journal Article LBNL Report Number LBNL-53943 Year of Publication 2004 Authors Singer, Brett C., Kenneth L. Revzan, Toshifumi Hotchi, Alfred T. Hodgson, and Nancy J. Brown Journal Atmospheric Environment Volume 38 Start Page Chapter Issue 16 Pagination 2483-2494 Abstract We present experimental data and semi-empirical models describing the sorption of organic gases in a simulated indoor residential environment. Two replicate experiments were conducted with 20 volatile organic compounds (VOCs) in a 50-m3 room finished with painted wallboard, carpet and cushion, draperies and furnishings. The VOCs span a wide volatility range and include ten Hazardous Air Pollutants. VOCs were introduced to the static chamber as a pulse and their gas-phase concentrations were measured during a net adsorption period and a subsequent net desorption period. Three sorption models were fit to the measured concentrations for each compound to determine the simplest formulation needed to adequately describe the observed behavior. Sorption parameter values were determined by fitting the models to adsorption period data then checked by comparing measured and predicted behavior during desorption. The adequacy of each model was evaluated using a goodness of fit parameter calculated for each period. Results indicate that sorption usually does not greatly affect indoor concentrations of methyl-tert-butyl ether, 2-butanone, isoprene and benzene. In contrast, sorption appears to be a relevant indoor process for many of the VOCs studied, including C8-C10 aromatic hydrocarbons (HC), terpenes, and pyridine. These compounds sorbed at rates close to typical residential air change rates and exhibited substantial sorptive partitioning at equilibrium. Polycyclic aromatic HCs, aromatic alcohols, ethenylpyridine and nicotine initially adsorbed to surfaces at rates of 1.5 to >6 h-1 and partitioned 95 to >99% in the sorbed phase at equilibrium

303

Room Air Conditioning Energy Efficiency and Demand Response Potential  

Science Conference Proceedings (OSTI)

Room or window air conditioners are a common appliance in parts of the United States residential sector for providing summertime cooling. The technology is based on the same vapor compression cycle common in central air conditioning and refrigeration applications, but with all system components in one enclosure, which is generally small and comparatively inexpensive. The systems are simple and modular enough to be installed by the homeowner, and can be installed in windows without major modification, or ...

2011-06-30T23:59:59.000Z

304

Community Activity Room (CAR) Code, Demo Version 1.0  

Science Conference Proceedings (OSTI)

Examining a computer image akin to a weather map, transmission system operators are now able to visualize congestion on the high voltage power lines that make up our nation's massive regional electricity grids. The multi-dimensional image, which represents power market activities, is made possible by a new software tool called the Community Activity Room, or CAR (TM). The colorful graphic shows the current state of wholesale power transactions and their effect on the reliability of an interconnected powe...

2002-09-10T23:59:59.000Z

305

OSU WEBVIEWER PROVIDING WEB BASED ACCESS TO ROOM SCHEDULING INFORMATION  

E-Print Network (OSTI)

for a specific room. You can also search for an event name. For example, entering ANTH will display all and the starting date of next term's CS 419 course. You'll notice there is no way to filter this search by date be ignored. If we want all 400 level CS courses, we just enter "cs 4". SPACE QUICK SEARCH OR LOOKUP You can

Escher, Christine

306

Plenary session Room F2 Chairman: Doc. J. Langer  

E-Print Network (OSTI)

. O Modeling of Bacterial Chemotaxis in Steady-state System 17:15 Poster Session Symposium Room M1., Glosik J. O State-selective Recombination of H3 + Ions with Electrons at Temperatures 50­300 K 14:55 f2 Referee: Prof. F. Marsik 13:30 f11 Netusil M. O Modeling of Arterial Wall ­ The Current State of Knowledge

307

Determination of the Acceptable Room Temperature Range for Local Cooling  

E-Print Network (OSTI)

Determination of the acceptable room temperature range is a key problem in satisfactory design of local cooling for energy savings. At the room temperatures ranging from neutral to warm, three sensitive body parts-the face, chest and back-were each exposed to local cooling airflow, where temperatures were 22, 25 and 28°C. Thirty randomly-selected male subjects, dressed in shorts, were exposed to each condition for 30 minutes. Data were collected on their local thermal sensations of each body part, overall thermal sensation, and overall thermal acceptability on voting scales at regular intervals during the exposure. Results show that the non-uniformity of thermal sensation is a key factor affecting thermal acceptability except for overall thermal sensation. A new assessment model for local cooling was proposed. The model shows that face cooling can improve thermal acceptability more than chest or back cooling, and the upper boundary of the acceptable range of room temperature can be shifted from 26°C to 30.5°C when face cooling is provided.

Zhang, Y.; Zhao, R.

2006-01-01T23:59:59.000Z

308

Research on Thermal Properties in a Phase Change Wallboard Room Based on Air Conditioning Cold Storage  

E-Print Network (OSTI)

After comparing the thermal performance parameters of an ordinary wall room to a phase change wall (PCW) room, we learn that phase change wallboard affects the fluctuation of temperature in air-conditioning room in the summer. We built a PCW room and an ordinary wall room, which are cooled by an air-conditioner. We used differential scanning calorimetry (DSC) to test the temperature field and heat flow fluctuation in these rooms. Through analyzing the data tested, we found that the mean temperature of PCW is lower than that of ordinary wall room by 1 to 2?, and PCW can lower the heat flow by 4.6W/m2. Combining phase change material with the building envelope can lower the indoor temperature, make the room thermally comfortable, and cut down the turn-on-and-off frequency of the air-conditioner and the primary investment and operating costs. It alleviates the urgent need for electricity.

Feng, G.; Li, W.; Chen, X.

2006-01-01T23:59:59.000Z

309

Tobacco smoke aging in the presence of ozone: a room-sized chamber...  

NLE Websites -- All DOE Office Websites (Extended Search)

Tobacco smoke aging in the presence of ozone: a room-sized chamber study Title Tobacco smoke aging in the presence of ozone: a room-sized chamber study Publication Type Journal...

310

Modeling of Heat Transfer in Rooms in the Modelica Buildings Library  

E-Print Network (OSTI)

for convective and radiative heat transfer yielded a twofoldModeling of Heat Transfer in Rooms in the Modelica “of California. MODELING OF HEAT TRANSFER IN ROOMS IN THE

Wetter, Michael

2013-01-01T23:59:59.000Z

311

How do operators monitor a complex, dynamic work domain? The impact of control room technology  

Science Conference Proceedings (OSTI)

Keywords: cognitive engineering, control rooms, human-machine interface, monitoring, nuclear power plants, process control, supervisory control

2001-06-01T23:59:59.000Z

312

INFORMATION INTEGRATION IN CONTROL ROOMS AND TECHNICAL OFFICES IN NUCLEAR POWER PLANTS  

E-Print Network (OSTI)

Information integration in control rooms and technical offices in nuclear power plants Report prepared within the framework of the

unknown authors

2001-01-01T23:59:59.000Z

313

Fuzzy expert system design for operating room air-condition control systems  

Science Conference Proceedings (OSTI)

In this study, a controlled fuzzy expert system (FES) was designed to provide the conditions necessary for operating rooms. For this purpose, existing operating rooms have been studied to see if there are more useful, reliable and comfortable ones. How ... Keywords: Adaptive fuzzy control, Expert systems, Fuzzy control systems, Operating room control

Nazmi Etik; Novruz Allahverdi; Ibrahim Unal Sert; Ismail Saritas

2009-08-01T23:59:59.000Z

314

Designing for man: advances in control room operation  

SciTech Connect

Considers the human factor in nuclear power plants in relation to improving control room and maintenance operations. Control room operators face thousands of dials, meters, and indicator lights dispersed over large control boards. Components may not be arranged in clearly identifiable panels of related elements; sometimes related controls may not be near each other. Extensive alarm systems may sometimes confuse rather than alert the operators; communications with other parts of the plant may be difficult. Maintenance personnel may have to squeeze past pipes and similar obstructions to make repairs while carrying equipment and tools, sometimes while wearing protective gear. EPRI has developed a cool suit consisting of 16 pounds of water-filled compartments built into a two-piece repair suit that can be frozen to keep body temperatures at acceptable levels for up to 2 hrs. in high-heat areas of the plant. An ergonomics guide, which examines alternative solutions to heat stress (such as rest cycles and worker screening) is also being developed. Because few new nuclear plants are currently being built, many of the improvements will be retrofits in existing plants. EPRI's human factors work emphasizes thorough validation of new techniques through simulators and mockups.

Lihach, N.

1982-07-01T23:59:59.000Z

315

Microsoft Word - SmallServerRoomEfficiencyFactSheet.docx  

NLE Websites -- All DOE Office Websites (Extended Search)

5E 5E Fact Sheet: Improving Energy Efficiency for Server Rooms and Closets Hoi Ying (Iris) Cheung, Rod Mahdavi, Steve Greenberg, Rich Brown and William Tschudi, Lawrence Berkeley National Laboratory (LBNL) Pierre Delforge, National Resources Defense Council (NRDC) Joyce Dickerson, Google Environmental Energy Technologies Division September 2012 DISCLAIMER This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor The Regents of the University of California, nor any of their employees, makes any warranty, express or implied, or assumes any legal responsibility for the accuracy, completeness, or usefulness of any information,

316

Variable Speed Fan Retrofits for Computer Room Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Variable-Speed Fan Variable-Speed Fan Retrofits for Computer-Room Air Conditioners Prepared for the U.S. Department of Energy Federal Energy Management Program Technology Case Study Bulletin By Lawrence Berkeley National Laboratory Steve Greenberg September 2013 2 Contacts Steve Greenberg Lawrence Berkeley National Laboratory One Cyclotron Road, 90R3111 Berkeley, California 94720 (510) 486-6971 segreenberg@lbl.gov For more information on FEMP, please contact: Will Lintner, P.E., CEM Federal Energy Management Program U.S. Department of Energy 1000 Independence Ave. S.W. Washington, D. C. 20585-0121 (202) 586-3120 william.lintner@ee.doe.gov 3 Acknowledgements EPRI: Dennis Symanski, Brian Fortenbery Synapsense: Garret Smith, Patricia Nealon Vigilent: Corinne Vita

317

Observation of visible luminescence from indium nitride at room temperature  

SciTech Connect

InN films were grown on sapphire substrates with AlN buffer layers by reactive sputtering. C-axis-oriented crystalline InN films with a wurtzite structure were confirmed by x-ray diffraction and Raman scattering. Strong photoluminescence (PL) at 1.87 eV, together with a clear absorption edge at 1.97 eV, was observed at room temperature, which clearly demonstrates that it is not accurate in the previous assignment of an {approx}0.7 eV fundamental band gap for intrinsic InN simply from PL and absorption data. The possible origin of the present large band gap was discussed in terms of the effects of oxygen and the Burstein-Moss shift.

Guo, Q.X.; Tanaka, T.; Nishio, M.; Ogawa, H.; Pu, X.D.; Shen, W.Z. [Department of Electrical and Electronic Engineering, Saga University, Saga 840-8502 (Japan); Laboratory of Condensed Matter Spectroscopy and Opto-Electronic Physics, Department of Physics, Shanghai Jiao Tong University, 1954 Hua Shan Road, Shanghai 200030 (China)

2005-06-06T23:59:59.000Z

318

The Committee convened in the Clark Room, Holiday Inn Capitol,  

U.S. Energy Information Administration (EIA) Indexed Site

MEETING MEETING - - - Thursday, April 25, 1996 - - - The Committee convened in the Clark Room, Holiday Inn Capitol, 550 C Street, S.W., Washington, D.C., at 9:00 a.m., Dr. Timothy D. Mount, Chairman, presiding. PRESENT: TIMOTHY D. MOUNT, Chairman SAMPRIT CHATTERJEE BRENDA G. COX JOHN D. GRACE CALVIN KENT GRETA M. LJUNG RICHARD A. LOCKHART DANIEL A. RELLES PRESENT (Continued): BRADLEY O. SKARPNESS G. CAMPBELL WATKINS ALSO PRESENT: RENEE MILLER YVONNE BISHOP MARY HUTZLER JAY HAKES DOUGLAS HALE ART HOLLAND ARTHUR RYPINSKI LOUISE GUEY-LEE JOHN CYMBALSKY ERIN BOEDECKER JERRY COFFEY INDER KUNDRA C O N T E N T S PAGE Presentation by Jay Hakes 6 Presentation by Yvonne Bishop 34 Presentation by Art Rypinski 43 Presentation by Richard A. Lockhart 61 Presentation by Douglas Hale 84

319

Generation of coherent terahertz pulses in ruby at room temperature  

Science Conference Proceedings (OSTI)

We have shown that a coherently driven solid state medium can potentially produce strong controllable short pulses of THz radiation. The high efficiency of the technique is based on excitation of maximal THz coherence by applying resonant optical pulses to the medium. The excited coherence in the medium is connected to macroscopic polarization coupled to THz radiation. We have performed detailed simulations by solving the coupled density matrix and Maxwell equations. By using a simple V-type energy scheme for ruby, we have demonstrated that the energy of generated THz pulses ranges from hundreds of pico-Joules to nano-Joules at room temperature and micro-Joules at liquid helium temperature, with pulse durations from picoseconds to tens of nanoseconds. We have also suggested a coherent ruby source that lases on two optical wavelengths and simultaneously generates THz radiation. We discussed also possibilities of extension of the technique to different solid-state materials.

Kuznetsova, Elena; Rostovtsev, Yuri; Kalugin, Nikolai G.; Kolesov, Roman; Kocharovskaya, Olga [Institute for Quantum Studies and Department of Physics, Texas A and M University, College Station, Texas 77843 (United States); Scully, Marlan O. [Institute for Quantum Studies and Department of Physics, Texas A and M University, College Station, Texas 77843 (United States); Princeton Institute for Material Science and Department of Mechanical and Aerospace Engineering, Princeton University, New Jersey 08544 (United States)

2006-08-15T23:59:59.000Z

320

COMMERCIAL UTILITY PERSPECTIVES ON NUCLEAR POWER PLANT CONTROL ROOM MODERNIZATION  

SciTech Connect

Commercial nuclear power plants (NPPs) in the United States need to modernize their main control rooms (MCR). Many NPPs have done partial upgrades with some success and with some challenges. The Department of Energy’s (DOE) Light Water Reactor Sustainability (LWRS) Program, and in particular the Advanced Instrumentation and Controls (I&C) and Information Systems Technologies Research and Development (R&D) Pathway within LWRS, is designed to assist commercial nuclear power industry with their MCR modernization efforts. As part of this framework, a survey was issued to utility representatives of the LWRS Program Advanced Instrumentation, Information, and Control Systems/Technologies (II&C) Utility Working Group to obtain their views on a range of issues related to MCR modernization, including: drivers, barriers, and technology options, and the effects these aspects will have on concepts of operations, modernization strategies, and staffing. This paper summarizes the key survey results and discusses their implications.

Jeffrey C. Joe; Ronald L. Boring; Julius J. Persensky

2012-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

200-GeV ISA with room temperature magnets  

SciTech Connect

A conceptual design study of 200-GeV proton intersecting storage accclerators with room temperature magnets is presented. The key to this study was thc desire to keep the electric power consumptiom to an acceptable level (40 MW). The design has been optimized by choosing small-gap (4 cm) aluminum coil dipoles operating at about 15 kG. The luminosity of this machine is limited to about 10/sup 32/ cm-/sup -2/ sec/sup -1/ by transverse space-charg e effects. An order of magnitude higher luminositics can be obtained by adding a booster of modest cost. A novel vacuum system using distributed Ti-sublimation pumps results in considerable savings. A cost comparison with a high-luminosity superconducting machine is given. (auth)

Willis, W.J.; Danby, G.T.; Hahn, H.; Halama, H.J.; Maschke, A.W.; Month, M.; Parzen, G.; Polk, I.

1974-02-11T23:59:59.000Z

322

SPRING 2011 JOB FAIR Job Fair: Wednesday, Feb 2, 2011 10 am to 3 pm  

E-Print Network (OSTI)

for hotel operations. Air conditioning systems use large amounts of energy and water, and because many, I'll reuse my towel.' That's 100 rooms. The hotels are saving not only the water and energy but also1 Changing How We Choose Hotels Would you pay more to stay in a hotel that took steps

Boone, Randall B.

323

Many exterior entry and walkway lights in residential and commercial  

E-Print Network (OSTI)

. E N V I R O N M E N T A L L Y S O U N D A N D E N E R G Y E F F I C I E N T #12;Hotel/motel staff, contractors, and utility staff can use the information on this system. Key next steps include: · Building Owners/Managers and Lighting Specifiers--Specify the LED Hybrid Outdoor Fixture. · Utility Staff

324

2002 TMS Annual Meeting & Exhibition: Bhakta Rath Honorary Dinner  

Science Conference Proceedings (OSTI)

Feb 18, 2002 ... February 17–21 · 2002 TMS ANNUAL MEETING · Seattle, Washington ... Location: Sheraton Seattle Hotel & Towers Room: Aspen Room

325

The Kolkata Paise Hotel Problem  

E-Print Network (OSTI)

For $N$ possible customers or agents and $N$ pricewise identical restaurants, we study the collective dynamical states of choices. Each evening, every agent makes his/her choice based on (a) his/her own past experiences and (b) the past restaurant utilisation records (available to everyone). Moreover, each agent makes his/her choice independent of others. If more than one agent turns up in any particular restaurant, one of them is randomly selected by the restaurant and the rest do not get any dinner that evening. Although the prices are the same for all the restaurants, there is a prevailing opinion across agents about the preference rankings of these restaurants and it is commonly shared by all the $N$ agents. Of the $N^N$ possible states, only $N!$ states are ``socially efficient" or Pareto efficient in the sense that no agent can be made better off without making any other agent worse off. This is achieved when all the agents get their dinners. In the absence of mutual interaction across agents occurance ...

Chakrabarti, Bikas K; Chakrabarti, Anindya-Sundar

2007-01-01T23:59:59.000Z

326

Application Summary HOTEL COMPANY, LLC  

Science Conference Proceedings (OSTI)

... Apprentices were trained in the craft and qualified by examination to become craftsmen. ... Apprentice Programs, Inspection/Audit by the Master ...

327

Airport, Transport & Hotel Information | ORNL  

NLE Websites -- All DOE Office Websites (Extended Search)

Airport Information SHARE Airport Information Information related to the Knoxville Airport is listed below. You can find individual airlines' websites by following the "Airlines"...

328

REWAS 2008: Hotel and Travel  

Science Conference Proceedings (OSTI)

The 40-mile coastline offers warm waters, calm surf and white sandy beaches. Average temperature is 25.5 degrees Celsius (78 degrees Fahrenheit).

329

Data:6470ceed-feec-4fc1-8224-82320d66e2ec | Open Energy Information  

Open Energy Info (EERE)

ceed-feec-4fc1-8224-82320d66e2ec ceed-feec-4fc1-8224-82320d66e2ec No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Empire District Electric Co (Missouri) Effective date: 2013/04/01 End date if known: Rate name: Schedule CB Commercial Service < 40 kW Sector: Commercial Description: This schedule is available to any general service customer on the lines of the Company whose electric load is not in excess of 40 kW, except those who are conveying electric service received to others whose utilization of same is for residential purposes other than transient or seasonal. Motels, hotels, inns, resorts, etc., and others who provide transient rooms and/or board service and/or provide service to dwellings on a transient or seasonal basis are not excluded from the use of this rate. The Company reserves the right to determine the applicability or the availability of this rate to any specific applicant for electric service.

330

Road to room-temperature superconductivity: A universal model  

E-Print Network (OSTI)

In a semiclassical view superconductivity is attributed exclusively to the advance of atoms' outer s electrons through the nuclei of neighbor atoms in a solid. The necessary progression of holes in the opposite direction has the electric and magnetic effect as if two electrons were advancing instead of each actual one. Superconductivity ceases when the associated lateral oscillation of the outer s electrons extends between neighbor atoms. If such overswing occurs already at T = 0, then the material is a normal conductor. Otherwise, lateral overswing can be caused by lattice vibrations at a critical temperature Tc or by a critical magnetic field Bc. Lateral electron oscillations are reduced - and Tc is increased - when the atoms of the outer s electrons are squeezed, be it in the bulk crystal, in a thin film, or under external pressure on the sample. The model is applied to alkali metals and alkali-doped fullerenes. Aluminum serves as an example of a simple metal with superconductivity. Application of the model to transition metals, intertransitional alloys and compounds of transition metals with other elements sheds light on the pattern of their critical temperature. More examples of the squeeze effect are provided by the superconductivity of PdH, MgB2, borocarbides, ferropnictides, and organic charge-transfer salts. The model also provides the superconduction mechanism in the oxide superconductors, exemplified by YBa2Cu3O7. Finally the model suggests which steps to take in order to reach superconductivity at room temperature and above.

Manfred Bucher

2013-02-15T23:59:59.000Z

331

Renewable energy has political support, room to grow  

Science Conference Proceedings (OSTI)

Renewable energy sources enjoy growing political support and have plenty of room to grow in the worldwide energy mix. And grow they will, according to most projections. The US Energy Information Administration`s (EIA`s) International Energy Outlook 1997 says consumption of hydroelectricity and other renewables will increase by 56% during 1995--2015. The renewable share of the total energy mix will remain at about current levels, however. The EIA projection includes only renewable fuels used in the generation of electricity. It therefore excludes most biomass energy. Despite the importance of biomass energy, data on consumption of it are sparse. IEA estimates that in the industrialized world, the biomass share of primary energy consumption amounts to 3.5%. Also excluded from EIA`s projection because of insufficiency of data are dispersed renewables, a category that includes energy consumed at the site of production, such as solar panels used for water heating. This paper discusses regional trends, North American activity, Western Europe, Asian developments, and the rest of the world.

NONE

1997-08-11T23:59:59.000Z

332

BSA 07-22: Compact Room-Temperature Radiation Detector for Oil ...  

These small, solid-state radiation detectors can be used at room temperature, making them more practical, mobile, and cost-effective than existing devices.

333

Design of a ventilation system for carbon dioxide reduction in two gym rooms.  

E-Print Network (OSTI)

?? This project is mainly focused on the improving and design of the ventilation system of two rooms at different levels of a gym (Friskis… (more)

Barroeta, Ander

2013-01-01T23:59:59.000Z

334

The Virtual Control Room for Fusion Energy Sciences (V3) (A24771)  

E-Print Network (OSTI)

Proc. Of The Virtual Control Room For Fusion Energy Sciences (V3)US DOE National Collaboratories Program Meeting(2004) Champaign Illinois, US, 2004999610460

Schissel, D.P.

2004-07-23T23:59:59.000Z

335

10:20AM, P1 Room Temperature Lasing From Excited Stated of ...  

Science Conference Proceedings (OSTI)

Quantum dots formed by highly strained epilayers undergoing a ... The quantum dots demonstrate room temperature photoluminescence at 1.32 um with a full ...

336

Large Room Temperature Magnetoresistance in FeCo-SiN Granular ...  

Science Conference Proceedings (OSTI)

Abstract Scope, Large magnetoresistance (MR) materials have broad applications in ... Giant Low-Field Magnetocaloric Effect with Small Hysteresis Near Room ...

337

BSA 07-22: Compact Room-Temperature Radiation Detector for Oil ...  

BSA 07-22: Compact Room-Temperature Radiation Detector for Oil & Gas Exploration. BNL Reference Number: BSA 07-22. Patent Status: U.S. Patent ...

338

Sunday, June 13, 2010 Arrival and hotel check-in (Shilla Hotel and The Suites Hotel)  

E-Print Network (OSTI)

Midzyzdroje, Island of Wolin, Poland 14 - 18 June 2010 Changing water, energy and biogeochemical cycles) of the Coordinated Energy and Water Cycle Observations Project (CEOP) within the Global Energy and Water Cycle has been on various aspects of regional climate change and its effects on water, energy

339

Sorption of organic gases in a furnished room  

SciTech Connect

We present experimental data and semi-empirical models describing the sorption of organic gases in a simulated indoor residential environment. Two replicate experiments were conducted with 20 volatile organic compounds (VOCs) in a 50-m{sup 3} room finished with painted wallboard, carpet and cushion, draperies and furnishings. The VOCs span a wide volatility range and include ten Hazardous Air Pollutants. VOCs were introduced to the static chamber as a pulse and their gas-phase concentrations were measured during a net adsorption period and a subsequent net desorption period. Three sorption models were fit to the measured concentrations for each compound to determine the simplest formulation needed to adequately describe the observed behavior. Sorption parameter values were determined by fitting the models to adsorption period data then checked by comparing measured and predicted behavior during desorption. The adequacy of each model was evaluated using a goodness of fit parameter calculated for each period. Results indicate that sorption usually does not greatly affect indoor concentrations of methyl-tert-butyl ether, 2-butanone, isoprene and benzene. In contrast, sorption appears to be a relevant indoor process for many of the VOCs studied, including C{sub 8}-C{sub 10} aromatic hydrocarbons (HC), terpenes, and pyridine. These compounds sorbed at rates close to typical residential air change rates and exhibited substantial sorptive partitioning at equilibrium. Polycyclic aromatic HCs, aromatic alcohols, ethenylpyridine and nicotine initially adsorbed to surfaces at rates of 1.5 to >6 h{sup -1} and partitioned 95 to >99% in the sorbed phase at equilibrium.

Singer, Brett C.; Revzan, Kenneth L.; Hotchi, Toshifumi; Hodgson, Alfred T.; Brown, Nancy J.

2003-11-30T23:59:59.000Z

340

Effect of room air recirculation delay on the decay rate of tracer gas  

NLE Websites -- All DOE Office Websites (Extended Search)

Effect of room air recirculation delay on the decay rate of tracer gas Effect of room air recirculation delay on the decay rate of tracer gas Title Effect of room air recirculation delay on the decay rate of tracer gas Publication Type Conference Proceedings Year of Publication 2004 Authors Kristoffersen, Astrid H., Ashok J. Gadgil, and David M. Lorenzetti Conference Name 9th International Conference on Air Distribution in Rooms - RoomVent 2004, Pagination pp 6 Date Published September 5-8, 2 Conference Location Coimbra, Portugal Abstract Tracer gas measurements are commonly used to estimate the fresh air exchange rate in a room or building. Published tracer decay methods account for fresh air supply, infiltration, and leaks in ductwork. However, the time delay associated with a ventilation system recirculating tracer back to the room also affects the decay rate. We present an analytical study of tracer gas decay in a well-mixed, mechanically-ventilated room with recirculation. The analysis shows that failing to account for delays can lead to under- or over-estimates of the fresh air supply, depending on whether the decay rate calculation includes the duct volume

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Boiler Room Coal Drying Heat Exchanger Numerical Computational Simulation and Analysis  

Science Conference Proceedings (OSTI)

Northeast area city district heating boiler room of coal with high moisture content, have caused a large number of waste of coal resources. Boiler coal drying heat exchanger is a long design cycle, testing workload and investment is more equipment. In ... Keywords: District heating boiler room, Dry heat exchanger, Numerical simulation, Heat transfer calculation

Zhao Xuefeng, Xiong Wen-zhuo

2012-07-01T23:59:59.000Z

342

Managing Complexity in TeamRooms, a Tcl-Based Internet Groupware Application  

E-Print Network (OSTI)

Managing Complexity in TeamRooms, a Tcl-Based Internet Groupware Application Mark Roseman Dept@cpsc.ucalgary.ca Abstract This paper describes TeamRooms, a Tcl-based real time groupware application that provides "network the use of several Tcl programming techniques -- meta-architectures, multiple interpreters, and embedded

Greenberg, Saul

343

UC Davis Medical Education Building | 4610 X Street | Room 1222 & 2222 ONLINE REGISTRATION  

E-Print Network (OSTI)

UC Davis Medical Education Building | 4610 X Street | Room 1222 & 2222 ONLINE REGISTRATION/ TECHNOLOGIST SYMPOSIUM Advances In Cardiovascular Medical and Surgical Care SAVE THE DATE Saturday, May 5, 2012-734-5512, janine.neely@ucdmc.ucdavis.edu. LOCATION UC Davis Medical Education Building 4610 X Street, Room 1222

Hammock, Bruce D.

344

Joan Stevens Hall 1st-year students. 242 242 single rooms.  

E-Print Network (OSTI)

single rooms, 38 twin-share places. $170­$213 Yes Yes # Gym area Music room 15 free off-street car parks fee* Electricity included in fee Internet included in fee Facilities available #12;uStay McKenzies = 1

Frean, Marcus

345

Room ventilation and its influence on the performance of fume cupboards: A parametric numerical study  

Science Conference Proceedings (OSTI)

The three-dimensional turbulent flow in a typical chemical laboratory containing two fume cupboards and furniture is investigated numerically in order to obtain detailed information needed for the improved design of ventilating systems for such rooms. The flow inside the two fume cupboards is simulated simultaneously with the room flow, and its dependence on the flow structure in the room is shown. The flow inside the cupboards and in the vicinity of their sash openings has been found to be essentially three-dimensional. Several room parameters are varied, and a quantitative evaluation of their influence on the flow, the comfort characteristics, and the ventilation efficiency is given. Additional ceiling-mounted openings, which extract room air outside the fume cupboards, can affect the capture efficiency of the cupboards, as well as the quality of the air in the room. It has been found also that small changes in the position of the radial inlet ceiling-mounted diffuser can influence the air quality of the room and at the same time the draught risk. These effects are shown for a given room arrangement. To accommodate the complex geometry, the elliptical nature of the mathematical problem, and the use of a turbulence model, a multigrid acceleration method with 245,000 control volumes is used, allowing CPU times on a workstation to become acceptable.

Denev, J.A.; Durst, F.; Mohr, B. [Friedrich Alexander Univ. Erlangen-Nuernberg, Erlangen (Germany)] [Friedrich Alexander Univ. Erlangen-Nuernberg, Erlangen (Germany)

1997-02-01T23:59:59.000Z

346

Human Factors Guidance for Control Room and Digital Human-System Interface Design and Modification  

Science Conference Proceedings (OSTI)

Operators of nuclear power plants face a significant challenge designing and modifying control rooms that will be produced at various stages of instrumentation and control (I&C) modernization. This report provides guidance on planning, specifying, designing, implementing, operating, maintaining, and training for modernized control rooms and digital human-system interfaces.

2005-12-08T23:59:59.000Z

347

Validation and Application of the Room Model of the Modelica Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Validation and Application of the Room Model of the Modelica Buildings Validation and Application of the Room Model of the Modelica Buildings Library Title Validation and Application of the Room Model of the Modelica Buildings Library Publication Type Conference Proceedings LBNL Report Number LBNL-5932E Year of Publication 2012 Authors Nouidui, Thierry Stephane, Kaustubh Phalak, Wangda Zuo, and Michael Wetter Conference Name Proc. of the 9th International Modelica Conference Date Published 09/2012 Conference Location Munich, Germany Abstract The Modelica Buildings library contains a package with a model for a thermal zone that computes heat transfer through the building envelope and within a room. It considers various heat transfer phenomena of a room, including conduction, convection, short-wave and long-wave radiation. The first part of this paper describes the physical phenomena considered in the room model. The second part validates the room model by using a standard test suite provided by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). The third part focuses on an application where the room model is used for simulation-based controls of a window shading device to reduce building energy consumption.

348

OVERVIEW OF A RECONFIGURABLE SIMULATOR FOR MAIN CONTROL ROOM UPGRADES IN NUCLEAR POWER PLANTS  

SciTech Connect

This paper provides background on a reconfigurable control room simulator for nuclear power plants. The main control rooms in current nuclear power plants feature analog technology that is growing obsolete. The need to upgrade control rooms serves the practical need of maintainability as well as the opportunity to implement newer digital technologies with added functionality. There currently exists no dedicated research simulator for use in human factors design and evaluation activities for nuclear power plant modernization in the U.S. The new research simulator discussed in this paper provides a test bed in which operator performance on new control room concepts can be benchmarked against existing control rooms and in which new technologies can be validated for safety and usability prior to deployment.

Ronald L. Boring

2012-10-01T23:59:59.000Z

349

A field demonstration of energy conservation using occupancy sensor lighting control in equipment rooms  

SciTech Connect

The Pacific Northwest Laboratory identified energy savings potential of automatic equipment-room lighting controls, which was demonstrated by the field experiment described in this report. Occupancy sensor applications have gained popularity in recent years due to improved technology that enhances reliability and reduces cost. Automatic lighting control using occupancy sensors has been accepted as an energy-conservation measure because it reduces wasted lighting. This study focused on lighting control for equipment rooms, which have inherent conditions ideal for automatic lighting control, i.e., an area which is seldom occupied, multiple users of the area who would not know if others are in the room when they leave, and high lighting energy intensity in the area. Two rooms were selected for this study: a small equipment room in the basement of the 337 Building, and a large equipment area in the upper level of the 329 Building. The rooms were selected to demonstrate the various degrees of complexity which may be encountered in equipment rooms throughout the Hanford Site. The 337 Building equipment-room test case demonstrated a 97% reduction in lighting energy consumption, with an annual energy savings of $184. Including lamp-replacement savings, a total savings of $306 per year is offset by an initial installation cost of $1,100. The installation demonstrates a positive net present value of $2,858 when the lamp-replacement costs are included in a life-cycle analysis. This also corresponds to a 4.0-year payback period. The 329 Building equipment-room installation resulted in a 92% reduction in lighting energy consumption. This corresponds to annual energy savings of $1,372, and a total annual savings of $2,104 per year including lamp-replacement savings. The life-cycle cost analysis shows a net present value of $15,855, with a 5.8-year payback period.

Dagle, J.E.

1992-09-01T23:59:59.000Z

350

Electrochemical Windows of Room-Temperature Ionic Liquids from Molecular Dynamics and Density Functional Theory Calculations  

E-Print Network (OSTI)

We investigated the cathodic and anodic limits of six room-temperature ionic liquids (ILs) formed from a combination of two common cations, 1-butyl-3-methylimidazolium (BMIM) and N,N-propylmethylpyrrolidinium (P13), and ...

Ong, Shyue Ping

351

HQFMSP Chapter 2, Limited Areas, Valut-Type Rooms and Temporary Limited  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2, Limited Areas, Valut-Type Rooms and Temporary 2, Limited Areas, Valut-Type Rooms and Temporary Limited Areas HQFMSP Chapter 2, Limited Areas, Valut-Type Rooms and Temporary Limited Areas October 2013 2013 Headquarters Facilities Master Security Plan - Chapter 2, Limited Areas, Valut-Type Rooms and Temporary Limited Areas This chapter covers the establishment, maintenance, and termination of areas within HQ buildings where classified activities take place. It covers the requirements applicable to each type of security area, including physical protection measures, controls on the use of electronic devices, restrictions on what security activities can take place, and what security equipment must be present. The procedures in this chapter were developed and are maintained jointly by HS-91 and the Office of Information Security

352

Human-factors engineering-control-room design review: Shoreham Nuclear Power Station. Draft audit report  

Science Conference Proceedings (OSTI)

A human factors engineering preliminary design review of the Shoreham control room was performed at the site on March 30 through April 3, 1981. This design review was carried out by a team from the Human Factors Engineering Branch, Division of Human Factors Safety. This report was prepared on the basis of the HFEB's review of the applicant's Preliminary Design Assessment and the human factors engineering design review/audit performed at the site. The presented sections are numbered to conform to the guidelines of the draft version of NUREG-0700. They summarize the teams's observations of the control room design and layout, and of the control room operators' interface with the control room environment.

Peterson, L.R.; Preston-Smith, J.; Savage, J.W.; Rousseau, W.F.

1981-04-24T23:59:59.000Z

353

Route to Room-Temperature Superconductivity from a Practical Point of View  

E-Print Network (OSTI)

To synthesize a new superconductor which has a critical temperature, Tc, exceeding the room temperature, one needs to know what chemical components to start with. This chapter presents analysis of experimental data which allow one to draw a conclusion about components and the structure of a potential room-temperature superconductor. The two essential components of a roomtemperature superconductor are large organic molecules (polymers, tissues) and atoms/molecules which are magnetic in the intercalated state. This conclusion is fully based on experimental facts known today, and does not require any assumptions about the mechanism of room-temperature superconductivity. This, however, does not mean that to synthesize a room-temperature superconductor is an easy task. Never let them persuade you that things are too difficult or impossible.

A. Mourachkine

2007-01-01T23:59:59.000Z

354

Numerical method for computing nonlinear, time dependent, buoyant circulation of air in rooms  

Science Conference Proceedings (OSTI)

A method is described which solves the dynamic equations for air circulation at Grashof numbers that are in the range of environmental temperatures of rooms. Previous two-dimensional computation techniques were limited to G ? 105 ...

J. E. Fromm

1971-05-01T23:59:59.000Z

355

NSLS ESH&Q | NSLS Laboratory Rooms and Experimental Safety Reviews  

NLE Websites -- All DOE Office Websites (Extended Search)

NSLS Laboratory Rooms and Experimental Safety Reviews Some beamlines have dedicated lab space. Fill out the form below and e-mail it to the Lab Steward for that beamline first. If...

356

Optical gain and lasing from band-engineered Ge-on-Si at room temperature  

E-Print Network (OSTI)

We present theoretical modeling and experimental results of optical gain and lasing from tensile-strained, n[superscript +] Ge-on-Si at room temperature. Compatible with silicon CMOS, these devices are ideal for large-scale ...

Liu, Jifeng

357

Room-temperature direct bandgap electroluminesence from Ge-on-Si light-emitting diodes  

E-Print Network (OSTI)

We report what we believe to be the first demonstration of direct bandgap electroluminescence (EL) from Ge/Si heterojunction light-emitting diodes (LEDs) at room temperature. In-plane biaxial tensile strain is used to ...

Sun, Xiaochen

358

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air  

NLE Websites -- All DOE Office Websites (Extended Search)

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners Title Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners Publication Type Report LBNL Report Number LBNL-63204 Year of Publication 2007 Authors McNeil, Michael A., and Maithili Iyer Date Published 03/2007 Keywords India Air Conditioner Efficiency Standards Abstract The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency.

359

Room coolers prior to 1930 and the technical impediments to their development  

SciTech Connect

Numerous attempts at room cooling can be found beginning in the mid 1800's. These attempts became more common as the refrigeration industry developed; however, it was not until the 1900's that the many technical problems were solved, primarily by the fledgling household refrigeration industry. Isolated installations of room cooling for residential and commercial use gave way to mass production of engineered products by the late 1920's, setting the stage for widespread manufacture and use in the 1930's and beyond.

Nagengast, B.A.

1986-01-01T23:59:59.000Z

360

TRANSIENT ACCIDENT ANALYSIS OF THE GLOVEBOX SYSTEM IN A LARGE PROCESS ROOM  

DOE Green Energy (OSTI)

Local transient hydrogen concentrations were evaluated inside a large process room when the hydrogen gas was released by three postulated accident scenarios associated with the process tank leakage and fire leading to a loss of gas confinement. The three cases considered in this work were fire in a room, loss of confinement from a process tank, and loss of confinement coupled with fire event. Based on these accident scenarios in a large and unventilated process room, the modeling calculations of the hydrogen migration were performed to estimate local transient concentrations of hydrogen due to the sudden leakage and release from a glovebox system associated with the process tank. The modeling domain represented the major features of the process room including the principal release or leakage source of gas storage system. The model was benchmarked against the literature results for key phenomena such as natural convection, turbulent behavior, gas mixing due to jet entrainment, and radiation cooling because these phenomena are closely related to the gas driving mechanisms within a large air space of the process room. The modeling results showed that at the corner of the process room, the gas concentrations migrated by the Case 2 and Case 3 scenarios reached the set-point value of high activity alarm in about 13 seconds, while the Case 1 scenario takes about 90 seconds to reach the concentration. The modeling results were used to estimate transient radioactive gas migrations in an enclosed process room installed with high activity alarm monitor when the postulated leakage scenarios are initiated without room ventilation.

Lee, S

2008-01-11T23:59:59.000Z

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

ICTs and the limits of integration: Converging professional routines and ICT support in colocated emergency response control rooms  

Science Conference Proceedings (OSTI)

In this article we have tried to establish how the nature of professional routines affects the ICT supported standardization and scripting of work performed by operators in Dutch colocated emergency response control rooms. In this type of multidisciplinary ... Keywords: Emergency response control room, ICTs, colocated control room, emergency response services, inter-organizational collaboration, professional routines

Stefan Soeparman; Hein van Duivenboden; Pieter Wagenaar; Peter Groenewegen

2008-12-01T23:59:59.000Z

362

MIT Plasma Science & Fusion Center: research>alcator>Conference Room  

NLE Websites -- All DOE Office Websites (Extended Search)

Density Physics Density Physics Waves & Beams Technology & Engineering Useful Links Conference Rooms The PSFC is using google apps for education to support calendars for shared resources. There are currently two calendars implemented. One for the Alcator C-Mod Run Schedule, and one to schedule the NW17-132 conference room. These links will display read only views of the calendars. In order to schedule the conference room visit your personal psfc calendar as described below. In order to view these calendars you must be signed in to the g-apps.psfc.mit.edu domain. When prompted by https://sso.psfc.mit.edu/ for a username and password, enter your PSFC login credentials. After you authenticate for the first time, you get a screen which asks you to accept new account. Note that: THIS IS DIFFERENT AND SEPARATE FROM YOUR OTHER GOOGLE

363

State of Washington officials join department of energy to dedicate WIPP disposal room  

NLE Websites -- All DOE Office Websites (Extended Search)

State of Washington Officials Join Department of Energy State of Washington Officials Join Department of Energy To Dedicate WIPP Disposal Room CARLSBAD, N.M., June 2, 2000 - U.S. Congressman Doc Hastings of Washington state joined U.S. Department of Energy (DOE) officials today in dedicating the "Washington Room" at the Waste Isolation Pilot Plant (WIPP). Disposal Room 2 of Panel 1 in the WIPP underground will be filled with transuranic radioactive waste from the Hanford Site near Richland, Wash., as well as other DOE facilities. "The state of Washington is pleased that WIPP is open and will soon accept transuranic waste from Hanford," said Congressman Hastings. "This event recognizes the years of cooperation and dedication among all parties in making WIPP a reality. It also shows continuing progress on the cleanup of the Hanford Site."

364

HYBRID ALARM SYSTEMS: COMBINING SPATIAL ALARMS AND ALARM LISTS FOR OPTIMIZED CONTROL ROOM OPERATION  

SciTech Connect

The US Department of Energy (DOE) is sponsoring research, development, and deployment on Light Water Reactor Sustainability (LWRS), in which the Idaho National Laboratory (INL) is working closely with nuclear utilities to develop technologies and solutions to help ensure the safe operational life extension of current nuclear power plants. One of the main areas of focus is control room modernization. Within control room modernization, alarm system upgrades present opportunities to meet the broader goals of the LWRS project in demonstrating the use and safety of the advanced instrumentation and control (I&C) technologies and the short-term and longer term objectives of the plant. In this paper, we review approaches for and human factors issues behind upgrading alarms in the main control room of nuclear power plants.

Ronald L. Boring; J.J. Persensky

2012-07-01T23:59:59.000Z

365

The role of hydrogen in room-temperature ferromagnetism at graphite surfaces  

DOE Green Energy (OSTI)

We present a x-ray dichroism study of graphite surfaces that addresses the origin and magnitude of ferromagnetism in metal-free carbon. We find that, in addition to carbon {pi} states, also hydrogen-mediated electronic states exhibit a net spin polarization with significant magnetic remanence at room temperature. The observed magnetism is restricted to the top {approx}10 nm of the irradiated sample where the actual magnetization reaches {approx_equal} 15 emu/g at room temperature. We prove that the ferromagnetism found in metal-free untreated graphite is intrinsic and has a similar origin as the one found in proton bombarded graphite.

Ohldag, Hendrik

2011-08-12T23:59:59.000Z

366

Laser sheet light flow visualization for evaluating room air flowsfrom Registers  

SciTech Connect

Forced air heating and cooling systems and whole house ventilation systems deliver air to individual rooms in a house via supply registers located on walls ceilings or floors; and occasionally less straightforward locations like toe-kicks below cabinets. Ideally, the air velocity out of the registers combined with the turbulence of the flow, vectoring of air by register vanes and geometry of register placement combine to mix the supply air within the room. A particular issue that has been raised recently is the performance of multiple capacity and air flow HVAC systems. These systems vary the air flow rate through the distribution system depending on the system load, or if operating in a ventilation rather than a space conditioning mode. These systems have been developed to maximize equipment efficiency, however, the high efficiency ratings do not include any room mixing effects. At lower air flow rates, there is the possibility that room air will be poorly mixed, leading to thermal stratification and reduced comfort for occupants. This can lead to increased energy use as the occupants adjust the thermostat settings to compensate and parts of the conditioned space have higher envelope temperature differences than for the well mixed case. In addition, lack of comfort can be a barrier to market acceptance of these higher efficiency systems To investigate the effect on room mixing of reduced air flow rates requires the measurement of mixing of supply air with room air throughout the space to be conditioned. This is a particularly difficult exercise if we want to determine the transient performance of the space conditioning system. Full scale experiments can be done in special test chambers, but the spatial resolution required to fully examine the mixing problem is usually limited by the sheer number of thermal sensors required. Current full-scale laboratory testing is therefore severely limited in its resolution. As an alternative, we used a water-filled scale model of a room in which whole-field supply air mixing maps of two vertical planes were measured using a Planar Laser-Induced Fluorescence (PLIF) measurement technique. Water marked with fluorescent dye was used to simulate the supply airflow; and the resulting concentrations within the water filled model show how the supply air mixes with the room air and are an analog for temperature (for thermal loads) or fresh air (for ventilation). In addition to performing experiments over a range of flow rates, we also changed register locations and examined the effects for both heating and cooling operation by changing the water density (simulating air density changes due to temperature changes) using dissolved salt.

Walker, Iain S.; Claret, Valerie; Smith, Brian

2006-04-01T23:59:59.000Z

367

Press Room  

NLE Websites -- All DOE Office Websites (Extended Search)

photos and graphics from Fermilab's online, up-to-the-minute archive. Video Archive Animations and videos based on streaming video technology, ready for watching without long...

368

Room-temperature electric-field controlled spin dynamics in ,,110... InAs quantum wells  

E-Print Network (OSTI)

Room-temperature electric-field controlled spin dynamics in ,,110... InAs quantum wells K. C. Halla pseudomagnetic fields exceeding 1 T when only 140 mV is applied across a single quantum well. Using this large­11 and the influence of the Rashba pseudomagnetic fields on the electron spin relaxation time in GaAs quantum wells

Flatte, Michael E.

369

Effect of room air recirculation delay on the decay rate of tracer gas  

NLE Websites -- All DOE Office Websites (Extended Search)

Effect of room air recirculation delay on the decay rate of tracer gas Effect of room air recirculation delay on the decay rate of tracer gas concentration Title Effect of room air recirculation delay on the decay rate of tracer gas concentration Publication Type Journal Article Year of Publication 2007 Authors Lorenzetti, David M., Astrid H. Kristoffersen, and Ashok J. Gadgil Journal Indoor Air Pagination 7 Keywords recirculating ventilation, tracer decay rate Abstract Tracer gas measurements are used to estimate the flow rate of fresh air into a room or building. These methods commonly account for the decay of tracer gas concentration as the result of ventilation air supply and infiltration, using a well-mixed model of the space. Some researchers also have considered the effect of leakage in the ventilation ductwork. This paper considers the effect of recirculation through ventilation ducts on the calculated fresh air supply rate. Transport delay in the ducts can significantly alter the time evolution of tracer concentration, and hence alter the estimated air change rate.

370

THE CONSTRUCTION AND OPERATION OF EXPERIMENTAL ROOMS FOR THE STUDY OF AIR-BORNE INFECTION*  

E-Print Network (OSTI)

In order to carry out adequately controlled studies on the effects of temperature and humidity on the behavior of bacteria and viruses suspended in the air under various experimental conditions, it became necessary to have available enclosed spaces in which any desired atmospheric state could be produced and maintained. The use of conventional methods of air conditioning is unsuitable for this purpose because all of these depend upon exchange of the air inside the experimental space with conditioned air. Hence, two identical air-tight, glass-walled rooms 8 feet X 10 feet and 8 feet high were built each within a separate air-conditioned shell which can be kept constantly at any temperature and relative humidity likely to be encountered in spaces occupied by human beings. Rapid circulation of the conditioned air over all surfaces of the inner room provides a sufficiently high rate of heat transfer to insure constant temperature conditions within that space. The relative humidity of the inner room can be maintained at the same level as the air of the outer shell or can be increased by the introduction of steam. Two rooms provide much greater

O. H. Robertson; Theodore T. Puck, Ph.D.; Henry Wise

1946-01-01T23:59:59.000Z

371

Study on Energy Saving of the Interlayer Ventilation Walla Used in Clean Operation Rooms  

E-Print Network (OSTI)

Recovery energy of the exhaust in air conditioning is very important to clean operating rooms. In disinfected operating rooms, we often use completely fresh air conditioning system in order to maintain cleanliness. All the return air of the air conditioning must be discharged. For recovering the exhaust energy, whole heat exchangers are used, and they may bring cross-infection in clean operating rooms. Cross-infection would negatively affect cleanness. This paper puts forward an air layer inside of a building's external wall that acts as a passageway for air conditioning exhaust, and also providing a place for the thermal exchange of the air conditioning exhaust. This kind of envelope is named an interlayer ventilation wall. There are two advantages. First, it will recover and reutilize the energy that the air conditioning exhaust takes, avoid cross-infection between the fresh air and the exhaust. Second, it will lower the energy loss of the heat exchange through the envelope. The energy saving effect will be very significant in clean operating rooms.

Feng, J.; Lian, Z.; Hou, Z.

2006-01-01T23:59:59.000Z

372

Fabrication of a Miniaturized Room Temperature Ionic Liquid Gas Sensor for Human Health and  

E-Print Network (OSTI)

Fabrication of a Miniaturized Room Temperature Ionic Liquid Gas Sensor for Human Health and Safety temperature ionic liquid (RTIL) gas sensors utilizing electrochemical instrumentation demonstrate promising that enables miniaturized, rapid response, gas sensors to be realized using RTIL interfaces on a permeable

Mason, Andrew

373

Current methods to handle wall conduction and room internal heat transfer  

SciTech Connect

This paper reviews methods of handling wall conduction and room internal heat exchange adopted by ASHRAE (1993 Handbook of Fundamentals and later developments), CIBSE (1986 Guide and current proposals), and the CEN/TC89/WG6 proposals to calculate heating and cooling loads and related topics.

Davies, M.G.

1999-07-01T23:59:59.000Z

374

Method of installing a control room console in a nuclear power plant  

DOE Patents (OSTI)

An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.

Scarola, Kenneth (Windsor, CT); Jamison, David S. (Windsor, CT); Manazir, Richard M. (North Canton, CT); Rescorl, Robert L. (Vernon, CT); Harmon, Daryl L. (Enfield, CT)

1994-01-01T23:59:59.000Z

375

ECE 461 FUNDAMENTALS OF SOLAR ENERGY Time/Day: TBA Room: TBA  

E-Print Network (OSTI)

1 ECE 461 FUNDAMENTALS OF SOLAR ENERGY Time/Day: TBA Room: TBA Instructor: Rajendra Singh Topics Covered Topic Hours Course Overview 1 Solar Energy: Introduction 2 Importance of Solar Energy as Clean & Sustainable Energy 3 Fundamentals & Technology of Solar Thermal Systems 3 Fundamentals

Bolding, M. Chad

376

Room-temperature oxygen sensitization in highly textured, nanocrystalline PbTe films: A mechanistic study  

E-Print Network (OSTI)

In this paper, we report large mid-wave infrared photoconductivity in highly textured, nanocrystalline PbTe films thermally evaporated on Si at room temperature. Responsivity as high as 25 V/W is measured at the 3.5 ?m ...

Wang, Jianfei

377

Electrical properties of room temperature sputtered Y2O3and MOSFET characteristics  

Science Conference Proceedings (OSTI)

We closely evaluated the properties of Y2O3 deposited by RF sputter system at room temperature for the application to a transparent thin film transistor. Although the leakage current density hardly depends on the deposition conditions, ... Keywords: IGZO, TTFT(transparent thin film transistor), Y2O3, electrical characterization, gate oxide, leakage current

Young-Je Cho; Ji-Hoon Shin; Jae-Kyu Lee; Young-Bae Kim; Duck-Kyun Choi

2008-02-01T23:59:59.000Z

378

A study towards applying thermal inertia for energy conservation in rooms  

Science Conference Proceedings (OSTI)

We are in an age where people are paying increasing attention to energy conservation around the world. The heating and air-conditioning systems of buildings introduce one of the largest chunks of energy expenses. In this article, we make a key observation ... Keywords: Thermal inertia, energy conservation, room management, wireless sensor networks

Yi Yuan; Dawei Pan; Dan Wang; Xiaohua Xu; Yu Peng; Xiyuan Peng; Peng-Jun Wan

2013-11-01T23:59:59.000Z

379

Trends in the living room and beyond: results from ethnographic studies using creative and playful probing  

Science Conference Proceedings (OSTI)

In this article we present the findings of two ethnographic studies embedded into two broader projects on interactive television in the home environment. Based on previous research on the home context and inspired by ongoing trends around interactive ... Keywords: cultural probes, ethnography, home context, interactive TV, living room

Regina Bernhaupt; Marianna Obrist; Astrid Weiss; Elke Beck; Manfred Tscheligi

2008-05-01T23:59:59.000Z

380

Design and performance of a rule-based controller in a naturally ventilated room  

Science Conference Proceedings (OSTI)

The objective of this work is to design and implement a fuzzy controller for naturally ventilated buildings. The controller is implemented in a test room using MATLABTM. Initially the controller was validated using simulated data. Simulations ... Keywords: fuzzy logic control, naturally ventilated buildings, thermal comfort

M. Eftekhari; L. Marjanovic; P. Angelov

2003-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

The KidsRoom: A Perceptually-Based Interactive and Immersive Story Environment  

Science Conference Proceedings (OSTI)

The KidsRoom is a perceptually-based, interactive, narrative playspace for children. Images, music, narration, light, and sound effects are used to transform a normal child's bedroom into a fantasy land where children are guided through a reactive adventure ...

Aaron F. Bobick; Stephen S. Intille; James W. Davis; Freedom Baird; Claudio S. Pinhanez; Lee W. Campbell; Yuri A. Ivanov; Arjan Schütte; Andrew Wilson

1999-08-01T23:59:59.000Z

382

A room temperature CuO nanowire sensor for organic volatile gases  

Science Conference Proceedings (OSTI)

CuO nanowires have been synthesised by the thermal method in 100% oxygen ambient at 600°C. Gas sensing property has been examined by measuring the resistance change of the materials to 1% of butane gas and 1% of ethanol vapour separately under the ... Keywords: copper oxide (CuO) nanowires, room temperature gas sensor and organic volatile gas

C. F. Dee; T. Y. Tiong; M. M. Salleh; M. M. Yahya; B. Y. Majlis

2011-02-01T23:59:59.000Z

383

Raman and IR spectra of butane: Anharmonic calculations and interpretation of room temperature spectra  

E-Print Network (OSTI)

Raman and IR spectra of butane: Anharmonic calculations and interpretation of room temperature-principles anharmonic calculations are carried out for the IR and Raman spectra of the CAH stretch- ing bands in butane.V. All rights reserved. 1. Introduction n-Butane is of great importance in several disciplines

Potma, Eric Olaf

384

Room temperature 1.6 m electroluminescence from Ge light emitting diode on Si substrate  

E-Print Network (OSTI)

Room temperature 1.6 µm electroluminescence from Ge light emitting diode on Si substrate Szu n+/p light emitting diode on a Si substrate. Unlike normal electrically pumped devices, this device.4670) Optical materials; (230.3670) Light-emitting diodes. References and links 1. L. C. Kimerling, "Silicon

Vuckovic, Jelena

385

Room-temperature mid-infrared laser sensor for trace gas detection  

E-Print Network (OSTI)

, and pipeline leak detection. Applications such as landfill emissions monitoring require measurements of gasRoom-temperature mid-infrared laser sensor for trace gas detection Thomas To¨ pfer, Konstantin P. Petrov, Yasuharu Mine, Dieter Jundt, Robert F. Curl, and Frank K. Tittel Design and operation

386

Dye-doped cholesteric-liquid-crystal room-temperature single-photon source*  

E-Print Network (OSTI)

Dye-doped cholesteric-liquid-crystal room-temperature single-photon source* SVETLANA G. LUKISHOVAy, 250 East River Road, Rochester, New York 14623-1299, USA (Received 30 June 2003) Abstract. Fluorescence antibunching from single terrylene molecules embedded in a cholesteric-liquid-crystal host is used

Stroud, Carlos R.

387

MULTI - TRACER CONTROL ROOM AIR INLEAKAGE PROTOCOL AND SIMULATED PRIMARY AND EXTENDED MULTI - ZONE RESULTS.  

SciTech Connect

The perfluorocarbon tracer (PFT) technology can be applied simultaneously to the wide range in zonal flowrates (from tens of cfms in some Control Rooms to almost 1,000,000 cfm in Turbine Buildings), to achieve the necessary uniform tagging for subsequent determination of the desired air inleakage and outleakage from all zones surrounding a plant's Control Room (CR). New types of PFT sources (Mega sources) were devised and tested to handle the unusually large flowrates in a number of HVAC zones in power stations. A review of the plans of a particular nuclear power plant and subsequent simulations of the tagging and sampling results confirm that the technology can provide the necessary concentration measurement data to allow the important ventilation pathways involving the Control Room and its air flow communications with all adjacent zones to be quantitatively determined with minimal uncertainty. Depending on need, a simple single or 3-zone scheme (involving the Control Room alone or along with the Aux. Bldg. and Turbine Bldg.) or a more complex test involving up to 7 zones simultaneously can be accommodated with the current revisions to the technology; to test all the possible flow pathways, several different combinations of up to 7 zones would need to be run. The potential exists that for an appropriate investment, in about 2 years, it would be possible to completely evaluate an entire power plant in a single extended multizone test with up to 12 to 13 separate HVAC zones. With multiple samplers in the Control Room near each of the contiguous zones, not only will the prevalent inleakage or outleakage zones be documented, but the particular location of the pathway's room of ingress can be identified. The suggested protocol is to perform a 3-zone test involving the Control Room, Aux. Bldg., and Turbine Bldg. to (1) verify CR total inleakage and (2) proportion that inleakage to distinguish that from the other 2 major buildings and any remaining untagged locations. These results would then direct the next subsequent tests. Final results would point to where mitigation steps should be initiated. Protocols for repeat testing as well as long term continual testing are suggested.

DIETZ,R.N.

2002-01-01T23:59:59.000Z

388

Symposium on the Global Energy Future October 1 5, 2010  

E-Print Network (OSTI)

to $5000 for travel related expenses to St. Louis in addition to providing one (1) hotel room at the Ritz of the institution. For example, the entire allowance can be utilized to cover the expenses of one guest only are the responsibility of the institution. Hotel rates and information are provided on the "Hotel Information" page

389

Journal of Arti cial Intelligence Research 15 2001 189-206 Submitted 2 01; published 9 01 ATTac-2000: An Adaptive Autonomous Bidding Agent  

E-Print Network (OSTI)

and departure dates; hotel rooms The Grand Hotel and Le Fleabag Inn; and entertainment tickets symphony, theater, and baseball. To obtain utility for a client, an agent must construct a travel package for that client by purchasing airline tickets to and from TACtown and securing hotel reservations; it is possible to obtain

Plotkin, Joshua B.

390

Helsinki Journal, Entry 29, February 4, 2007 This weekend Alex and I took a trip to a remote region in eastern Finland near the  

E-Print Network (OSTI)

to the research exercise. One natural approach is for researchers to cooperate, by addressing their design energy) room reservations at two available hotels­one considered higher quality than the other, and (3 on the first day), eight hotel auctions (two hotel types and four nights), and twelve entertainment ticket

Bardsley, John

391

Optimization of X-ray Radiographic Imaging Birsen Yazici, Il-Young Son, An Jin  

E-Print Network (OSTI)

- Energy Storage and Organic Photovoltaic Devices - Next-Generation Organic Materials and Device after July 14, 2010. Accommodations Hotels Many comfortable hotels with easy access to the conference venue are located along with the subway lines in Kyoto City. Blocks of rooms at the following hotels

Yazici, Birsen

392

Communication Between U.S. Nuclear Waste Technical Review Board  

E-Print Network (OSTI)

hotel brand to mandate that all its properties pursue USGBC's Leadership in Energy and Environmental,000 hotels within a decade. Starwood will aim for a 30 percent reduction in energy use per available roomAug. 2, 2010, 9:00 a.m. EDT · Recommend · Post: PRESS RELEASE Element Hotels, Starwood's "Green

393

TMS 2010 Corporate Sponsorship  

Science Conference Proceedings (OSTI)

Cyber Center - SOLD! Event Signage - SOLD! Exhibit Entrance - SOLD! Exhibitor Lounge; Hotel Room Key Holder w/Map - SOLD! Information Booth - SOLD!

394

program addendum (pdf download)  

Science Conference Proceedings (OSTI)

Sep 19, 2007 ... “High Efficiency Solid State Lighting: Solutions for Global Warming”. Location: MGM Grand Hotel Conference Center, Room: Premier. Ballroom.

395

PRICM-3: Travel and Destination Information  

Science Conference Proceedings (OSTI)

Each guest room has air conditioning, alarm clocks, balcony, cable TV with HBO, ... fee of $200 to their registration to assist in paying meeting space at the hotel.

396

Register for TMS 2010  

Science Conference Proceedings (OSTI)

February 14-18, 2010 • Washington State Convention Center • Seattle, WA ... Book a room at either the Sheraton Seattle Hotel or the Westin Seattle and you will ...

397

TMS e-News: The monthly electronic newsletter for TMS  

Science Conference Proceedings (OSTI)

Room reservations at the Marriott New Orleans Hotel, where the conference will take place, must be made by August 26. .... Houston, Texas February 10-12 ...

398

Federal Register /Vol. 67, No. 140/Monday, July 22, 2002/Notices 47777  

U.S. Energy Information Administration (EIA)

the Westgate Hotel located at 1055 Second Avenue, San Diego, CA 92101. ... Department of Energy, Forrestal Building—Room 8H–089, 1000 Independence Avenue NW.,

399

2001 TMS FALLMEETING CALENDAR OF EVENTS  

Science Conference Proceedings (OSTI)

Oct 5, 2002 ... Crowne Plaza Hotel Riviera Room. SUNDAY, OCTOBER 6, 2002. Meeting Activities. Registration. 2:00pm-7:00pm. Convention Center. Hall C.

400

The Annual DOE JGI User Meeting  

NLE Websites -- All DOE Office Websites (Extended Search)

Hotels, Travel, Meals, etc. Hotels, Travel, Meals, etc. Venue Hotel A limited block of rooms for User Meeting attendees has been set aside at the Marriott Hotel Walnut Creek, the meeting venue, which is convenient to the Walnut Creek BART stop and about a ten-minute drive from the JGI. The room rate for this limited-room block is $117/night. Rooms in the block will be available on a first-come, first-served basis and will be held until February 24, 2014. (After this date, the discounted rate will be contingent upon room availability and the hotel's occupancy). Government ID will not be required to receive this rate; however, you will need to mention the correct reservation code (see below) when you make your reservation. Marriott Hotel 2355 North Main Street Walnut Creek, CA 94596 Phone: (925) 934-2000

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

LED Light Fixture Project FC1 Director's Conference Room: Life Cycle Cost and Break-even Analysis  

E-Print Network (OSTI)

LED Light Fixture Project ­ FC1 Director's Conference Room: Life Cycle Cost and Break-even Analysis. #12;LED Light Fixture Project ­ FC1 Director's Conference Room: Life Cycle Cost and Break,812 Maintenance Cost $620 $0 $97 $0 Life Cycle Cost $1,787 $1,693 $2,980 $2,980 #12;LED Light Fixture Project ­ FC

Hofmann, Hans A.

402

REDUCTIONS WITHOUT REGRET: DETAILS - AVOIDING BOX CANYONS, ROACH MOTELS, AND WRONG TURNS  

SciTech Connect

The United States is concurrently pursuing the goals of reducing the size of its nuclear weapons force – strategic and non-strategic, deployed and non-deployed – and of modernizing the weapons it continues to possess. Many of the existing systems were deployed 30 to 50 years ago, and the modernization process can be expected to extend over the next decade or more. Given the impossibility of predicting the future over the lifetime of systems that could extend to the end of this century, it is essential that dead ends in force development be avoided, and the flexibility and availability of options be retained that allow for • Scalability downward in the event that further reductions are agreed upon; • Reposturing to respond to changes in threat levels and to new nuclear actors; and • Breakout response in the event that a competitor significantly increases its force size or force capability, In this paper, we examine the current motivations for reductions and modernization; review a number of historical systems and the attendant capabilities that have been eliminated in recent decades; discuss the current path forward for the U.S. nuclear force; provide a view of the evolving deterrence situation and our assessment of the uncertainties involved; and present examples of possibly problematic directions in force development. We close with our thoughts on how to maintain flexibility and the availability of options for which a need might recur in the future.

Swegle, John A.; Tincher, Douglas J.

2013-08-09T23:59:59.000Z

403

BEYOND INTEGRATED SYSTEM VALIDATION: USE OF A CONTROL ROOM TRAINING SIMULATOR FOR PROOF-OF-CONCEPT INTERFACE DEVELOPMENT  

Science Conference Proceedings (OSTI)

This paper provides background on a reconfigurable control room simulator for nuclear power plants. The main control rooms in current nuclear power plants feature analog technology that is growing obsolete. The need to upgrade control rooms serves the practical need of maintainability as well as the opportunity to implement newer digital technologies with added functionality. There currently exists no dedicated research simulator for use in human factors design and evaluation activities for nuclear power plants in the US. The new research simulator discussed in this paper provides a test bed in which operator performance on new control room concepts can be benchmarked against existing control rooms and in which new technologies can be validated for safety and usability prior to deployment.

Ronald Boring; Vivek Agarwal

2012-07-01T23:59:59.000Z

404

CFN Operations and Safety Awareness (COSA) Checklist Nanofabrication (Clean Room) Facility  

NLE Websites -- All DOE Office Websites (Extended Search)

Nanofabrication (Clean Room) Facility Nanofabrication (Clean Room) Facility Building 735 This COSA form must be completed for all experimenters working in the CFN and must be submitted to the CFN User Office for badge access. CFN Safety Awareness Policy: Each user must be instructed in the safe procedures in CFN related activities. CFN Facility Laboratory personnel shall keep readily available all relevant instructions and safety literature. Employee/Guest Name Life/Guest Number Department/Division ES&H Coordinator/Ext. Facility Manager COSA Trainer Guest User Staff USER ADMINISTRATION Checked in at User Administration and has valid BNL ID badge Safety Approval Form (SAF) approved. Training requirements completed (Indicate additional training specified in SAF or ESR in lines provided below):

405

Section_201_Establishing_Maintaining_and_Deactivating_Limited_and_Vault-Type_Rooms  

NLE Websites -- All DOE Office Websites (Extended Search)

201 201 Establishing, Maintaining, and Deactivating Limited Areas and Vault-Type Rooms Description Classified matter must be processed, discussed, handled, or stored in designated Limited Areas (LAs) or Vault-Type Rooms (VTRs). LAs and VTRs must have security measures in place to detect and deter unauthorized persons from gaining access to the classified matter. This includes measures to prevent unauthorized persons from seeing or hearing classified information. All LAs and VTRs at Headquarters (HQ) must be approved by the Office of HQ Security Operations (HS-90) prior to the initiation of classified activities or the introduction of classified material or equipment. Definitions of a LA and VTR: 1. Limited Area (LA)--An LA is a security area designated for the protection of classified

406

Impact of the Energy Efficiency Labeling and Standards Program on Room  

NLE Websites -- All DOE Office Websites (Extended Search)

Impact of the Energy Efficiency Labeling and Standards Program on Room Impact of the Energy Efficiency Labeling and Standards Program on Room Air-conditioner in Korea Speaker(s): Jun-Young Choi Date: January 31, 2006 - 12:00pm Location: Bldg. 90 There is a significant amount of trade in energy-using equipment all over the world. A study of trade in air conditioners, refrigerators, electric motors and lighting products found that air-conditioner trade all among all economies was worth about US$35 billion in 2003. Window/wall air conditioners represented about 40% of the value of trade, and other types (split system and ducted types) about 60%. Air conditioner is the one of most energy-consuming equipments in residential sector, which reaches to include air conditioner in MEPS and energy labeling program in many economies. Much of this trade is affected in some way by minimum energy

407

The role of hydrogen in room-temperature ferromagnetism at graphite surfaces  

DOE Green Energy (OSTI)

We present a x-ray dichroism study of graphite surfaces that addresses the origin and magnitude of ferromagnetism in metal-free carbon. We find that, in addition to carbon {pi} states, also hydrogen-mediated electronic states exhibit a net spin polarization with significant magnetic remanence at room temperature. The observed magnetism is restricted to the top {approx}10 nm of the irradiated sample where the average magnetization reaches {approx_equal} 15 emu/g at room temperature. We prove that the ferromagnetism found in metal-free untreated graphite is intrinsic and has a similar origin as the one found in proton bombarded graphite. Also, our findings show that the magnetic properties of graphite surfaces, thin films or two dimensional graphene samples can be reliably studied using soft x-ray dichroism. Fundamental new insight into the magnetic properties of carbon based systems can thus be obtained.

Ohldag, H.; Esquinazi, P.; Arenholz, E.; Spemann, D.; Rothermel, M.; Setzer, A.; Butz, T.

2010-05-01T23:59:59.000Z

408

Building a Model Patient Room to Test Design Innovations With Actual Patients  

E-Print Network (OSTI)

comfortable hospital environment SUMMARY Designing and constructing a new hospital is a complex and costly undertaking that involves experts from many disciplines both inside and outside the health care arena. But despite expending funds and time, hospital leaders often discover significant flaws once a hospital opens that can undermine the quality of patient care and staff effectiveness and efficiency. From 2010 to 2012, a team at the Princeton HealthCare System worked to devise an optimal design for inpatient rooms at a new hospital: the University Medical Center of Princeton at Plainsboro. The project entailed building a “functional model patient room.” This was a unique and innovative method to allow the team to test design innovations with actual patients, according to project director Susan Lorenz, DrNP, RN, vice president of patient care services and chief nursing officer for the Princeton HealthCare System. The project helped support the emerging field of evidence-based hospital design.

A Princeton; More Efficient; Key Results

2013-01-01T23:59:59.000Z

409

Mirror thermal noise in laser interferometer gravitational wave detectors operating at room and cryogenic temperature  

E-Print Network (OSTI)

Mirror thermal noise is and will remain one of the main limitations to the sensitivity of gravitational wave detectors based on laser interferometers. We report about projected mirror thermal noise due to losses in the mirror coatings and substrates. The evaluation includes all kind of thermal noises presently known. Several of the envisaged substrate and coating materials are considered. The results for mirrors operated at room temperature and at cryogenic temperature are reported.

Janyce Franc; Nazario Morgado; Raffaele Flaminio; Ronny Nawrodt; Iain Martin; Liam Cunningham; Alan Cumming; Sheila Rowan; James Hough

2009-12-01T23:59:59.000Z

410

Pushover, Response Spectrum and Time History Analyses of Safe Rooms in a Poor Performance Masonry Building  

Science Conference Proceedings (OSTI)

The idea of safe room has been developed for decreasing the earthquake casualties in masonry buildings. The information obtained from the previous ground motions occurring in seismic zones expresses the lack of enough safety of these buildings against earthquakes. For this reason, an attempt has been made to create some safe areas inside the existing masonry buildings, which are called safe rooms. The practical method for making these safe areas is to install some prefabricated steel frames in some parts of the existing structure. These frames do not carry any service loads before an earthquake. However, if a devastating earthquake happens and the load bearing walls of the building are destroyed, some parts of the floors, which are in the safe areas, will fall on the roof of the installed frames and the occupants who have sheltered there will survive. This paper presents the performance of these frames located in a destroying three storey masonry building with favorable conclusions. In fact, the experimental pushover diagram of the safe room located at the ground-floor level of this building is compared with the analytical results and it is concluded that pushover analysis is a good method for seismic performance evaluation of safe rooms. For time history analysis the 1940 El Centro, the 2003 Bam, and the 1990 Manjil earthquake records with the maximum peak accelerations of 0.35g were utilized. Also the design spectrum of Iranian Standard No. 2800-05 for the ground kind 2 is used for response spectrum analysis. The results of time history, response spectrum and pushover analyses show that the strength and displacement capacity of the steel frames are adequate to accommodate the distortions generated by seismic loads and aftershocks properly.

Mazloom, M. [Department of Civil Engineering, Shahid Rajaee University, P.O. Box 16785-163, Tehran (Iran, Islamic Republic of)

2008-07-08T23:59:59.000Z

411

Design and Validation of Control Room Upgrades Using a Research Simulator Facility  

SciTech Connect

Since 1981, the United States (U.S.) Nuclear Regulatory Commission (NRC) [1] requires a plant- specific simulator facility for use in training at U.S. nuclear power plants (NPPs). These training simulators are in near constant use for training and qualification of licensed NPP operators. In the early 1980s, the Halden Man-Machine Laboratory (HAMMLab) at the Halden Reactor Project (HRP) in Norway first built perhaps the most well known set of research simulators. The HRP offered a high- fidelity simulator facility in which the simulator is functionally linked to a specific plant but in which the human-machine interface (HMI) may differ from that found in the plant. As such, HAMMLab incorporated more advanced digital instrumentation and controls (I&C) than the plant, thereby giving it considerable interface flexibility that researchers took full advantage of when designing and validating different ways to upgrade NPP control rooms. Several U.S. partners—the U.S. NRC, the Electrical Power Research Institute (EPRI), Sandia National Laboratories, and Idaho National Laboratory (INL) – as well as international members of the HRP, have been working with HRP to run control room simulator studies. These studies, which use crews from Scandinavian plants, are used to determine crew behavior in a variety of normal and off-normal plant operations. The findings have ultimately been used to guide safety considerations at plants and to inform advanced HMI design—both for the regulator and in industry. Given the desire to use U.S. crews of licensed operators on a simulator of a U.S. NPP, there is a clear need for a research simulator facility in the U.S. There is no general-purpose reconfigurable research oriented control room simulator facility in the U.S. that can be used for a variety of studies, including the design and validation of control room upgrades.

Ronald L. Boring; Vivek Agarwal; Jeffrey C. Joe; Julius J. Persensky

2012-11-01T23:59:59.000Z

412

Room temperature ferromagnetism in Mn, Ni and Co ions doped Cu{sub 2}O nanorods  

SciTech Connect

Here we report the synthesis and characterization of Cu{sub 2}O nanorods doped with Mn, Ni and Co transition metal ions and the study of their magnetic properties. Synthesis of the nanorods was carried out by the modified polyol method. Powder X-ray diffraction patterns clearly showed them to be polycrystalline single phase material. They exhibited ferromagnetic behavior at room temperature, however no such behavior was observed for the reference undoped sample, which indicated that unintentionally introduced magnetic impurities were not responsible for the observed phenomenon. Ferromagnetic behavior was found to be dependent on the dopant concentration and increased consistently with its increment in the material. The total magnetic moments contribution was calculated for the dopant concentration and was found to be insignificant to account for the observed ferromagnetism, therefore it was suggested that ferromagnetism could have conjured up from the induced magnetic moment in the defects created as cation vacancies in the material. The presence of the defects was supported by the room temperature photoluminescence study which showed that intensity of the peaks was dependent on the dopant concentration and increased consistently with it. There was strong correlation between the magnitude of the photoluminescence peak and the observed ferromagnetic property in the doped samples. -- Graphical Abstract: Room temperature ferromagnetism was observed in the Cu{sub 2}O nanorods doped with Mn, Ni and Co ions. The origin seems to be the defects of cation vacancies created by the dopant ions. Display Omitted

Ahmed, Asar [Department of Chemistry, SL-214, Southern Lab, Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh (India); Gajbhiye, Namdeo S., E-mail: nsg@iitk.ac.i [Department of Chemistry, SL-214, Southern Lab, Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh (India)

2010-12-15T23:59:59.000Z

413

Risk associated with hospital rooms contaminated with 131I by patients being treated for thyroid carcinoma  

E-Print Network (OSTI)

Iodine-131 contamination is known to be present in hospital rooms that are used to confine patients being treated with quantities of 1311 in excess of 1. 1 GBq. These activities of 13 'I are used as a post-surgical follow-up procedure to a thyroidectomy as a means of treating thyroid cancer. Previous studies have indicated the extent of contamination in hospital rooms being used during these procedures. However, contamination has not been related to risk. This paper quantifies the risk in terms of effective dose equivalent to members of the public and personnel from 1311 contamination when only minimal precautions are taken to contain the contamination during the 1311 thyroid cancer treatment procedure. Total Effective Dose Equivalent (TEDE) calculations using the NRC published dose models for surface contamination results in public exposures of less than 2.7 uSv per patient and personnel exposures of less than 2.1 uSv yr-1. Maximum TEDE to the public considering the detectable limits of portable area survey equipment indicated a worst case exposure of 340 uSv per patient. As a result, conservative protective measures utilized by many institutions, such a lining the room with plastic, appear not to be warranted.

Jones, David Maurice

1995-01-01T23:59:59.000Z

414

Commissioning Tools for Heating/Cooling System in Residence - Verification of Floor Heating System and Room Air Conditioning System Performance  

E-Print Network (OSTI)

Tools of evaluating the performance of floor heating and room air conditioner are examined as a commissioning tool. Simple method is needed to check these performance while in use by residents, because evaluation currently requires significant time and effort. Therefore, this paper proposes a) two methods of evaluating the floor heating efficiency from the room / crawl space temperature and the energy consumption and b) method of evaluating COP of the room air conditioner from the data measured at the external unit. Case studies in which these tools were applied to actual residences are presented to demonstrate their effectiveness.

Miura, H.; Hokoi, S.; Iwamae, A.; Umeno, T.; Kondo, S.

2004-01-01T23:59:59.000Z

415

2005 EIA-821 SURVEY: LINE-BY-LINE REFERENCE GUIDE  

U.S. Energy Information Administration (EIA) Indexed Site

Page 1 Page 1 2012 EIA-821 SURVEY: LINE-BY-LINE REFERENCE GUIDE Kerosene Line No. Sold directly to consumers for: 1 Residential Use (Non-Farm): * Backup generator * Home heating and cooking * Personal lawn equipment * EXCLUDE: Apartment buildings and Farmhouses 2 Commercial Use: * Apartment building * Bank * Casino * Church * College/School/Institution * Department/Retail store * Environmental clean-up service * Flushing fuel lines * Forestry service * Golf course * Government (Federal, State, local, and district; INCLUDE fuel used in vehicles) * Hazardous waste company * Hospital * Hotel/Motel * Landfill site government owned * Landscaping * Laundry company * Lumber yard that sells the lumber * Medical service * Port Authority/publicly owned port or loading dock

416

Property:CBECSSubCategories | Open Energy Information  

Open Energy Info (EERE)

CBECSSubCategories CBECSSubCategories Jump to: navigation, search This is a property of type String. Subproperties This property has the following 1 subproperty: S Service Pages using the property "CBECSSubCategories" Showing 13 pages using this property. E Education + elementary or middle school +, high school +, college or university +, ... F Food Sales + grocery store or food market +, gas station with a convenience store +, convenience store + Food Service + fast food +, restaurant or cafeteria + H Health Care (Inpatient) + hospital +, inpatient rehabilitation + Health Care (Outpatient) + medical office +, clinic or other outpatient health care +, outpatient rehabilitation +, ... L Lodging + motel or inn; hotel; dormitory +, fraternity +, or sorority; retirement home; nursing home +, ...

417

Characterization of commercial building appliances. Final report  

SciTech Connect

This study focuses on ``other`` end-uses category. The purpose of this study was to determine the relative importance of energy end-use functions other than HVAC and lighting for commercial buildings, and to identify general avenues and approaches for energy use reduction. Specific energy consuming technologies addressed include non-HVAC and lighting technologies in commercial buildings with significant energy use to warrant detailed analyses. The end-uses include office equipment, refrigeration, water heating, cooking, vending machines, water coolers, laundry equipment and electronics other than office equipment. The building types include offices, retail, restaurants, schools, hospitals, hotels/motels, grocery stores, and warehouses.

Patel, R.F.; Teagan, P.W.; Dieckmann, J.T.

1993-08-01T23:59:59.000Z

418

On-site fuel cell field test support program. Annual report Jul 81-Jun 82  

SciTech Connect

United continued this past year to assist the utilities and the Gas Research Institute in the review and selection of sites for data monitoring. Each of these sites will be instrumented and its energy requirements monitored and analyzed for one year prior to the selection of 40 Kilowatt fuel cell field test sites. Analyses in support of the selection of sites for instrumentation continued to show that many building sectors offered considerable market potential. These sectors include nursing home, health club, restaurant, industrial, hotel/motel and apartment.

Staniunas, J.W.; Merten, G.P.

1982-09-01T23:59:59.000Z

419

Lodging | Open Energy Information  

Open Energy Info (EERE)

Lodging Lodging Jump to: navigation, search Building Type Lodging Definition Buildings used to offer multiple accommodations for short-term or long-term residents, including skilled nursing and other residential care buildings. Sub Categories motel or inn; hotel; dormitory, fraternity, or sorority; retirement home; nursing home, assisted living, or other residential care; convent or monastery; shelter, orphanage, or children's home; halfway house References EIA CBECS Building Types [1] References ↑ EIA CBECS Building Types U.S. Energy Information Administration (Oct 2008) Retrieved from "http://en.openei.org/w/index.php?title=Lodging&oldid=270114" Category: CBECS Building Types What links here Related changes Special pages Printable version Permanent link

420

Human Factors Guidance for Control Room and Digital Human-System Interface Design and Modification, Guidelines for Planning, Specification, Design, Licensing, Implementation, Training, Operation and Maintenance  

Science Conference Proceedings (OSTI)

Nuclear plant operators face a significant challenge designing and modifying control rooms. This report provides guidance on planning, designing, implementing and operating modernized control rooms and digital human-system interfaces.

R. Fink, D. Hill, J. O'Hara

2004-11-30T23:59:59.000Z

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

WIPP supplementary roof support system Room 1, Panel 1: Geotechnical field data analysis report  

SciTech Connect

The design of the Room 1, Panel 1, supplementary roof support system was finalized in September 1991, and the system successfully installed in the test bin area between the bulkheads by December 1991. Simultaneously with the support system installation, existing monitoring system was upgraded to meet the needs of the installed roof support. This included extensometers, closure stations, rockbolt load cells as well as survey measurements of roof sag and floor lift. A Project Control Group (PCG) was established in order to monitor room and support system performance. Weekly meetings of the PCG were held to review all monitored data against criteria set in the initial design, and to modify these where necessary. Records of these meetings have been kept, with copies of all data summaries and action notes. These data records are maintained in the Engineering data files. After more than ten months of monitoring and reviewing experience, several modifications have been made both to the way data has been reported as well as to the load adjustment criteria. The support system has performed as expected in the design, with no signs of instability developing considering the rates of roof deformation, the rock bolt loads and the observed fracture behavior in the roof. This is particularly true of the horizon in which the rockbolt anchors are located, the most critical part of the design. The distribution of load build-up, throughout the 286 rockbolt load cells installed, in the Room 1 has been found satisfactory, and the load increases as evaluated by the PCG on a weekly basis have been within the acceptable range. The minimum life of the installed support system is estimated at 15 years based on the highest roof expansion rate experienced to date. This report provides analysis of geotechnical field data collected up to December 1992.

1993-03-01T23:59:59.000Z

422

Minimizing lighting power density in office rooms equipped with Anidolic Daylighting Systems  

Science Conference Proceedings (OSTI)

Electric lighting is responsible for up to one third of an office building's electricity needs. Making daylight more available in office buildings can not only contribute to significant energy savings but also enhance the occupants' performance and wellbeing. Anidolic Daylighting Systems (ADS) are one type of very effective facade-integrated daylighting systems. All south-facing office rooms within the LESO solar experimental building in Lausanne (Switzerland) are equipped with a given type of ADS. A recent study has shown that these offices' occupants are highly satisfied with their lighting environment. The most energy-efficient south-facing offices have a lighting power density of less than 5W/m{sup 2}. The lighting situation within these ''best practice''-offices has been assessed using the lighting simulation software RELUX Vision. Because this lighting situation is very much appreciated by the occupants, it was used as a starting point for developing even more energy-efficient office lighting designs. Two new lighting designs, leading to lighting power densities of 3.9W/m{sup 2} and 3W/m{sup 2}, respectively, have been suggested and simulated with RELUX Vision. Simulation results have shown that the expected performances of these new systems are comparable to that of the current lighting installation within the ''best practice''-offices or even better. These simulation results have been confirmed during experiments on 20 human subjects in a test office room recently set up within the LESO building. This article gives engineers, architects and light planers valuable information and ideas on how to design energy-efficient and comfortable electric lighting systems in office rooms with abundant access to daylight. (author)

Linhart, Friedrich; Scartezzini, Jean-Louis [Solar Energy and Building Physics Laboratory (LESO-PB), Ecole Polytechnique Federale de Lausanne (EPFL), 1015 Lausanne (Switzerland)

2010-04-15T23:59:59.000Z

423

The Committee met in the Clark Room in the Holiday Inn Capitol,  

U.S. Energy Information Administration (EIA) Indexed Site

FRIDAY FRIDAY APRIL 24, 1998 - - - The Committee met in the Clark Room in the Holiday Inn Capitol, 550 C Street, S.W., Washington, D.C., at 9:00 a.m., Daniel Relles, Chair, presiding. PRESENT: DANIEL RELLES Chair CHARLES BISCHOFF Member CAROL CRAWFORD Member CALVIN KENT Member GRETA M. LJUNG Member POLLY PHIPPS Member SEYMOUR SUDMAN Member ROY WHITMORE Member JAMES HAMMITT Guest I N D E X Page Opening Comments from the Chair 3 Recognizing Previous Judges of the EIA Graphics 4 Contest and Announcing Winners, Jay Hakes EIA Survey Issues: Addressing Declining Budgets 12 Dwight French (EIA) Discussion: Seymour Sudman (ASA) 36 Questions from the Committee 45

424

Room-Temperature Ferromagnetism in Ion-Implanted Co-Doped TiO?(110) Rutile  

SciTech Connect

Interest in diluted magnetic semiconductros (DMS) is growing rapidly within the emerging field of spintronics. For example, the ability to efficiently inject spin-polarized carriers into nonmagnetic semiconductor heterostructures creates new and exciting possibilities for utilizing DMS materials in spin-based devices. Several III-V and II-VI semiconductor materials doped with magnetic transition metal elements have been explored. Although these materials show promising behavior in some cases, most exhibit Curie temperatures of ~170 K or less. It has recently been shown that certain oxide semiconductors doped with magnetic transition elements show room-temperature ferromagnetism.

Shutthanandan, V.; Thevuthasan, Suntharampillai; Heald, Steve M.; Droubay, Timothy; Engelhard, Mark H.; Kaspar, Tiffany C.; McCready, David E.; Saraf, Laxmikant V.; Chambers, Scott A.; Mun, B. S.; Hamdan, N. M.; Nachimuthu, Ponnusamy; Taylor, B.; Sears, R.; Sinkovic, Boris

2004-05-31T23:59:59.000Z

425

Analysis of Energy Saving in a Clean Room Air-conditioning System  

E-Print Network (OSTI)

To address the issue of the substantial energy cost and operating cost of an all-return air system for a clean room, we changed the former system to a 2nd return air system. With the newest building energy simulation program, Energy Plus, we simulated and compared the summer energy consuming conditions of the two systems. Results prove the superiority of the 2nd return air system, and the validity of the simulation. Also, the air system energy performance in summer was illustrated with typical meteorological hour-to-hour data.

Liu, S.; Liu, J.; Pei, J.; Wang, M.

2006-01-01T23:59:59.000Z

426

Floatabilities of treated coal in water at room temperature. Annual topical report, September 1992--August 1993  

SciTech Connect

This report contains a research paper entitled ``Floatability of Treated Coal in Water at Room Temperature.`` Experimental data on equilibrium adsorption loadings of probe compounds on coal, and flotation of raw coals as well as treated coal were obtained, using Illinois No. 6 coal (PSOC-1539), Adaville No. 1 coal (PSOC-1544), Wyodak coal (PSOC-1545) and Pittsburgh No. 8 coal (PSOC-1549). The raw data of this Annual Topical Report are also available in the Quarterly Progress Report for the period April--June 1993 and the Quarterly Progress Report July--September 1993.

Kwon, K.C. [Tuskegee Univ., AL (United States). Dept. of Chemical Engineering; Rohrer, R.L.; Lai, R.W.; Finseth, D.H. [USDOE Pittsburgh Energy Technology Center, PA (United States)

1993-12-31T23:59:59.000Z

427

Oxygen Reordering Near Room temperature in YBa2Cu3O6+x: A Thermodynamic Model  

SciTech Connect

We propose a thermodynamic model to explain an unusual phase transformation occurring near room temperature in YBa{sub 2}Cu{sub 3}O{sub 6+x} that greatly affects properties of the superconductor. Based on our model, the material's thermodynamic response functions, specific heat, thermal-expansion coefficient, and elastic compliances are deduced at the critical temperature of the phase transformation. We discuss the change of critical temperature with stress, and analyze the anomaly of specific heat in critical temperature of the phase transformation.

Meng, Q.; Welch, D.; Zhu, Y.

2011-04-14T23:59:59.000Z

428

Enhanced room temperature electronic and thermoelectric properties of the dilute bismuthide InGaBiAs  

SciTech Connect

We report room temperature electronic and thermoelectric properties of Si-doped In{sub 0.52}Ga{sub 0.48}Bi{sub y}As{sub 1-y} with varying Bi concentrations. These films were grown epitaxially on a semi-insulating InP substrate by molecular beam epitaxy. We show that low Bi concentrations are optimal in improving the conductivity, Seebeck coefficient, and thermoelectric power factor, possibly due to the surfactant effects of bismuth. We observed a reduction in thermal conductivity with increasing Bi concentration, which is expected because of alloy scattering. We report a peak ZT of 0.23 at 300 K.

Dongmo, Pernell; Zhong Yujun; Bomberger, Cory; Zide, Joshua [Department of Materials Science and Engineering, University of Delaware, Newark, Delaware 19716 (United States); Attia, Peter [Department of Chemical Engineering, University of Delaware, Newark, Delaware 19716 (United States); Cheaito, Ramez; Hopkins, Patrick E. [Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, Virginia 2294 (United States); Ihlefeld, Jon F. [Sandia National Laboratories, P.O. Box 5800, M.S. 1069, Albuquerque, New Mexico 87185 (United States)

2012-11-01T23:59:59.000Z

429

Reference Buildings by Building Type: Small Hotel  

Energy.gov (U.S. Department of Energy (DOE))

In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

430

Reference Buildings by Building Type: Large Hotel  

Energy.gov (U.S. Department of Energy (DOE))

In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

431

Julian Szekely Memorial Symposium: Royal Sonesta Hotel  

Science Conference Proceedings (OSTI)

... easy access to the historic waterfront, Quincy Market and the financial district. ... If you need any additional information on location directions, please contact ...

432

Extended-stay hotel as home.  

E-Print Network (OSTI)

??Housing plays an important interpersonal and sociopolitical role in American culture. Perceptions of personal achievement and life satisfaction in adulthood are often determined by the… (more)

Lewinson, Terri Wingate

2007-01-01T23:59:59.000Z

433

ENERGY STAR Success Story: Loews Hotels  

NLE Websites -- All DOE Office Websites (Extended Search)

variable frequency drives on large motors across all 18 facilities 30% reduction in motor electric load Installed capacitors on large pumps, motors, and air handler units in...

434

Avoiding 100 new power plants by increasing efficiency of room air conditioners in India: opportunities and challenges  

SciTech Connect

Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40% cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

Phadke, Amol; Abhyankar, Nikit; Shah, Nihar; [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

2013-10-15T23:59:59.000Z

436

An indoor radon survey of the X-ray rooms of Mexico City hospitals  

SciTech Connect

This paper presents the results of measurements of indoor radon concentrations in the X-ray rooms of a selection of hospitals in the metropolitan area of Mexico City. The metropolitan area of Mexico City is Mexico's largest metropolitan area by population; the number of patients requiring the use of X-rays is also the highest. An understanding of indoor radon concentrations in X-ray rooms is necessary for the estimation of the radiological risk to which patients, radiologists and medical technicians are exposed. The indoor radon concentrations were monitored for a period of six months using nuclear track detectors (NTD) consisting of a closed-end cup system with CR-39 (Lantrack Registered-Sign ) polycarbonate as detector material. The indoor radon concentrations were found to be between 75 and 170 Bq m{sup -3}, below the USEPA-recommended indoor radon action level for working places of 400 Bq m{sup -3}. It is hoped that the results of this study will contribute to the establishment of recommended action levels by the Mexican regulatory authorities responsible for nuclear safety.

Juarez, Faustino [Facultad de Ciencias, Universidad Autonoma del Estado de Mexico, Instituto Literario No. 100. Estado de Mexico, 50000, Mexico. Instituto de Geofisica, Universidad Nacional Autonoma de Mexico, Circuito (Mexico); Reyes, Pedro G. [Facultad de Ciencias, Universidad Autonoma del Estado de Mexico, Instituto Literario No. 100. Estado de Mexico, 50000 (Mexico); Espinosa, Guillermo [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Circuito Exterior Ciudad Universitaria, Mexico D.F. Cp.04510 (Mexico)

2013-07-03T23:59:59.000Z

437

Supported Room Temperature Ionic Liquid Membranes for CO{sub 2}/CH{sub 4} Separation  

SciTech Connect

Room temperature ionic liquids (RTILs) are organic salts which are liquid at or around room temperature. These compounds exhibit many outstanding physical properties such as great thermal stability and no measurable vapor pressure. In this work supported ionic liquid membranes (SILMs) were prepared by impregnating pores of ?-alumina inorganic supports with various ionic liquids. In addition to membranes prepared with pure RTILs we were able to synthesize membranes with RTIL mixtures using 1-aminopyridinium iodide dissolved in 1-butyl-4-methylpyridinium tetrafluoroborate or methyltrioctylammonium bis(trifluoromethylsulfonyl)imide. This combination of an RTIL with an organic salt containing an amine group dramatically improved the membrane separation properties. The SILMs displayed CO{sub 2} permeance on the order of 5 × 10{sup ?10} to 5 × 10{sup ?9} mol m{sup ?2} s{sup ?1} Pa{sup ?1} combined with CO{sub 2}/CH{sub 4} selectivity of 5–30. Although these values are comparable with the current systems for CO{sub 2} purification, CO{sub 2} permeance is still rather low for these compounds.

Iarikov, D. D.; Hacarlioglu, P.; Oyama, S. T.

2011-01-01T23:59:59.000Z

438

Room temperature all-silicon photonic crystal nanocavity light emitting diode at sub-bandgap wavelengths  

E-Print Network (OSTI)

Silicon is now firmly established as a high performance photonic material. Its only weakness is the lack of a native electrically driven light emitter that operates CW at room temperature, exhibits a narrow linewidth in the technologically important 1300- 1600 nm wavelength window, is small and operates with low power consumption. Here, an electrically pumped all-silicon nano light source around 1300-1600 nm range is demonstrated at room temperature. Using hydrogen plasma treatment, nano-scale optically active defects are introduced into silicon, which then feed the photonic crystal nanocavity to enahnce the electrically driven emission in a device via Purcell effect. A narrow ({\\Delta}{\\lambda} = 0.5 nm) emission line at 1515 nm wavelength with a power density of 0.4 mW/cm2 is observed, which represents the highest spectral power density ever reported from any silicon emitter. A number of possible improvements are also discussed, that make this scheme a very promising light source for optical interconnects a...

Shakoor, A; Cardile, P; Portalupi, S L; Gerace, D; Welna, K; Boninelli, S; Franzo, G; Priolo, F; Krauss, T F; Galli, M; Faolain, L O

2013-01-01T23:59:59.000Z

439

Ashford TRS Nickel, LP 3800 American Boulevard East, Bloomington MN 55425  

E-Print Network (OSTI)

to as "Hotel") and Regents of the University of Minnesota, through its (hereinafter referred DATES: «ARR_DATE» -«DEPARTDATE» GUEST ROOM COMMITMENT The hotel agrees that it will provide and University agrees that it will be responsible for utilizing the total number of room nights as indicated

Weiblen, George D

440

MINUTES OF THE BOARD OF REGENTS NEW MEXICO STATE UNIVERSITY  

E-Print Network (OSTI)

The Board of Regents of New Mexico State University met in the Hacienda Room of the Hotel Santa Fe, in Santa, in the Canyon Room of the Hotel Santa Fe, in Santa Fe, New Mexico, to discuss personnel, legal, and real estate) Approval of Grant of Underground Utility Easement to El Paso Electric Company from the Regents of New

Castillo, Steven P.

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

The Committee met in the Columbia Room at the Holiday Inn  

U.S. Energy Information Administration (EIA) Indexed Site

Friday, April 21, 1995 - - - The Committee met in the Columbia Room at the Holiday Inn Capitol, 550 C Street S.W., Washington, D.C., at 9:00 a.m., Timothy D. Mount, Chairman, presiding. PRESENT: TIMOTHY D. MOUNT, Chair DAVID R. BELLHOUSE CHARLES W. BISCHOFF BRENDA G. COX FAYE DUCHIN JOHN D. GRACE PHILIP HANSWER CALVIN KENT GRETA M. LJUNG JAMES L. O'BRIEN DANIEL A. RELLES BRADLEY O. SKARPNESS G. CAMPBELL WATKINS A-G-E-N-D-A Page No. Introductory Remarks, TIMOTHY MOUNT, Chairman 3 Announcement of Winners on Contest On 3 Statistical Graphs, LARRY PETTIS Review of Survey Design for Residential Energy Consumption Survey BRENDA COX, Discussant 7 DAVID BELLHOUSE, Discussant 29 Dates for Future Meetings, TIMOTHY MOUNT 42

442

The Committee met at 8:30 a.m., in Room 8E-089, Forrestal  

U.S. Energy Information Administration (EIA) Indexed Site

+ + + + + + + + + + FALL MEETING + + + + + Friday, November 3, 2000 + + + + + The Committee met at 8:30 a.m., in Room 8E-089, Forrestal Building, U.S. Department of Energy, 1000 Independence Avenue, S.W., Washington, D.C., Dr. Carol Gotway Crawford, Chairperson, presiding. PRESENT: CAROL A. GOTWAY CRAWFORD, Ph.D., Chairperson F. JAY BREIDT, Ph.D., Vice Chairperson THOMAS G. COWING, Ph.D. JAMES K. HAMMITT, Ph.D. CALVIN A. KENT, Ph.D. W. DAVID MONTGOMERY, Ph.D. WILLIAM G. MOSS, Ph.D. PRESENT (Continued): POLLY A. PHIPPS, Ph.D. RANDY R. SITTER, Ph.D. ROY W. WHITMORE, Ph.D. GUESTS PRESENT: JOHNNY BLAIR NICOLAS HENGARTNER ALSO PRESENT: STAN FREEDMAN, Designated Federal Official MARK MAZUR, Acting Administrator, EIA LARRY PETTIS, Deputy Administrator, EIA C-O-N-T-E-N-T-S

443

The meeting was held at 8:30 in Room 8E-089 of the Department  

U.S. Energy Information Administration (EIA) Indexed Site

THURSDAY, THURSDAY, OCTOBER 24, 2002 The meeting was held at 8:30 in Room 8E-089 of the Department of Energy, 1000 Independence Avenue, S.W., Washington, D.C., Carol A. Gotway Crawford, Chair, presiding. PRESENT: CAROL A. GOTWAY CRAWFORD, Ph.D. Chair F. JAY BREIDT, Ph.D. Vice Chair MARK BERNSTEIN, Ph.D. JOHNNY BLAIR MARK BURTON, Ph.D. JAY EDMONDS, Ph.D. JAMES K. HAMMITT, Ph.D. NICHOLAS W. HENGARTNER WILLIAM G. MOSS, Ph.D. POLLY A. PHIPPS, Ph.D. RANDY R. SITTER, Ph.D. ROY WHITMORE, Ph.D. ENERGY INFORMATION ADMINISTRATION REPRESENTATIVES: GUY F. CARUSO Administrator MARY J. HUTZLER Acting Deputy Administrator NANCY J. KIRKENDALL Director, Statistics and Methods Group RICHARD BONSKOWSKI ELIZABETH CAMPBELL

444

The Committee met in Room 1E-246 of the Forrestal Building at  

U.S. Energy Information Administration (EIA) Indexed Site

MEETING MEETING + + + + + THURSDAY NOVEMBER 19, 1998 The Committee met in Room 1E-246 of the Forrestal Building at the Department of Energy, 1000 Independence Avenue, S.W., Washington, D.C., at 8:30 a.m., Daniel A. Relles, Chair, presiding. PRESENT: DANIEL A. RELLES Chair CAROL GOTWAY CRAWFORD Vice Chair DAVID R. BELLHOUSE CHARLES W. BISCHOFF JAY BREIDT R. SAMPRIT CHATTERJEE JAMES HAMMITT GRETA M. LJUNG POLLY A. PHIPPS SEYMOUR SUDMAN ALSO PRESENT: ERIN BOEDECKER STEPHEN CALOPEDIS LYNDA CARLSON SAM COHEN JOHN COLLIGAN CATHY DIPPO STAN FREEDMAN DWIGHT FRENCH JAY HAKES MARY HUTZLER W. CALVIN KILGORE PERRY LINDSTROM HERB MILLER RENEE MILLER BETSY O'BRIEN LARRY PETTIS ARTHUR RYPINSKI HANK SATTLETHIGHT JOHN SHERWELL BILL WEINIG C O N T E N T S PAGE Welcome 5

445

The Committee met in the Columbia Room at the Holiday Inn Capitol,  

U.S. Energy Information Administration (EIA) Indexed Site

THURSDAY, THURSDAY, APRIL 20, 1995 The Committee met in the Columbia Room at the Holiday Inn Capitol, 550 C Street, S.W., Washington, D.C., at 9:00 a.m., Timothy D. Mount, Chair, presiding. PRESENT: TIMOTHY D. MOUNT, Chair DAVID R. BELLHOUSE CHARLES W. BISCHOFF BRENDA G. COX FAYE DUCHIN JOHN D. GRACE PHILIP HANSER CALVIN KENT GRETA M. LJUNG JAMES L. O'BRIEN DANIEL A. RELLES BRADLEY O. SKARPNESS G. CAMPBELL WATKINS AGENDA Introductions by Committee Chair . . . . . . . . . 3 Opening Remarks by Administrator . . . . . . . . . 6 Summary of EIA Follow-up on Comments From Previous Meetings, Yvonne Bishop . . . . . . . . 28 Effects of Structural Changes in Industry 1. Electricity Issues Impact on EIA's Data Collection Activities . . 31 Noel Balthasar, Presenter Phil Hanser, Discussant

446

Direct Observation of Room-Temperature Polar Ordering in Colloidal GeTe Nanocrystals  

SciTech Connect

Ferroelectrics and other materials that exhibit spontaneous polar ordering have demonstrated immense promise for applications ranging from non-volatile memories to microelectromechanical systems. However, experimental evidence of polar ordering and effective synthetic strategies for accessing these materials are lacking for low-dimensional nanomaterials. Here, we demonstrate the synthesis of size-controlled nanocrystals of the polar material germanium telluride (GeTe) using colloidal chemistry and provide the first direct evidence of room-temperature polar ordering in nanocrystals less than 5 nm in size using aberration-corrected transmission electron microscopy. Synchrotron x-ray diffraction and Raman studies demonstrate a sizeable polar distortion and a reversible size-dependent polar phase transition in these nanocrystals. The stability of polar ordering in solution-processible nanomaterials suggests an economical avenue to Tbit/in2-density non-volatile memory devices and other applications.

Polking, Mark J.; Zheng, Haimei; Urban, Jeffrey J.; Milliron, Delia J.; Chan, Emory; Caldwell, Marissa A.; Raoux, Simone; Kisielowski, Christian F.; Ager III, Joel W.; Ramesh, Ramamoorthy; Alivisatos, A.P.

2009-12-07T23:59:59.000Z

447

Scanning tunneling microscopy reveals LiMnAs is a room temperature anti-ferromagnetic semiconductor  

SciTech Connect

We performed scanning tunneling microscopy and spectroscopy on a LiMnAs(001) thin film epitaxially grown on an InAs(001) substrate by molecular beam epitaxy. While the in situ cleavage exposed only the InAs(110) non-polar planes, the cleavage continued into the LiMnAs thin layer across several facets. We combined both topography and current mappings to confirm that the facets correspond to LiMnAs. By spectroscopy we show that LiMnAs has a band gap. The band gap evidenced in this study, combined with the known Neel temperature well above room temperature, confirms that LiMnAs is a promising candidate for exploring the concepts of high temperature semiconductor spintronics based on antiferromagnets.

Wijnheijmer, A. P.; Koenraad, P. M. [COBRA Inter-University Research Institute, Department of Applied Physics, Eindhoven University of Technology, P. O. Box 513, NL-5600 MB Eindhoven (Netherlands); Marti, X. [Faculty of Mathematics and Physics, Charles University in Prague, Ke Karlovu 3, 121 16 Prague 2 (Czech Republic); Institute of Physics ASCR, v.v.i., Cukrovarnicka 10, 162 53 Prague 6 (Czech Republic); Holy, V. [Faculty of Mathematics and Physics, Charles University in Prague, Ke Karlovu 3, 121 16 Prague 2 (Czech Republic); Cukr, M.; Novak, V. [Institute of Physics ASCR, v.v.i., Cukrovarnicka 10, 162 53 Prague 6 (Czech Republic); Jungwirth, T. [Institute of Physics ASCR, v.v.i., Cukrovarnicka 10, 162 53 Prague 6 (Czech Republic); School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD (United Kingdom)

2012-03-12T23:59:59.000Z

448

Room-temperature diluted magnetic semiconductors p-(Ga,Ni)N  

SciTech Connect

High concentration (5 at. %) Ni was incorporated into a chemical vapor deposition-grown GaN film by using a thin protecting Ni layer on top of the GaN film during ion implantation. After etching off the protecting layer, subsequent annealing up to 800 deg. C under flowing N{sub 2} resulted in a p-type GaN with apparent ferromagnetic behavior up to {approx}320 K. In addition, the ferromagnetic behavior became more manifest with increasing annealing temperature that increases hole concentration. No presence of any other second phases nor clusters in the Ni-implanted region was identifiable, at least to the 0.2 nm point-to-point resolution of high resolution transmission electron microscopy. This novel indirect implantation process that being easy to implement appears promising for attaining room-temperature diluted magnetic semiconductors which are applicable to magnetotransport, magneto-optical and spintronics devices, among others.

Huang, R.-T.; Hsu, C.-F.; Kai, J.-J.; Chen, F.-R.; Chin, T.-S. [Department of Engineering and System Science, National Tsing-Hua University, Hsinchu 300, Taiwan (China); Department of Materials Science and Engineering, National Tsing-Hua University, Hsinchu 300, Taiwan (China)

2005-11-14T23:59:59.000Z

449

Room-Temperature Ferromagnetism in Chemically Synthesized Sn?-xCox O? Powders  

SciTech Connect

Room temperature ferromagnetism is observed in chemically synthesized powder samples of Sn??xCox O? with x = 0.005 and 0.01. Magnetic hysteresis loops are ovserved at 300K with coercivity Hc ~ 630 Oe, saturation magnetization Ms ~0.133?? and about 31% remenance. Analyses of the magnetization data of paramagnetic samples with x = 0.01 and 0.03, measured as a function of temperature (3-330K) and magnetic field (up to 50kOe), indicated the presence of Co²? ions with spin S = 3/2. Magnetic data obtained from samples prepared at different temperatures indicate that the observed ferromagnetism for x ? 0.01 might have been triggered by changes in the oxygen stiochiometry.

Punnoose, Alex; Hays, Jason S.; Gopal, Vidyut; Shutthanandan, V.

2004-08-30T23:59:59.000Z

450

Method for stabilizing low-level mixed wastes at room temperature  

DOE Patents (OSTI)

A method to stabilize solid and liquid waste at room temperature is provided comprising combining solid waste with a starter oxide to obtain a powder, contacting the powder with an acid solution to create a slurry, said acid solution containing the liquid waste, shaping the now-mixed slurry into a predetermined form, and allowing the now-formed slurry to set. The invention also provides for a method to encapsulate and stabilize waste containing cesium comprising combining the waste with Zr(OH).sub.4 to create a solid-phase mixture, mixing phosphoric acid with the solid-phase mixture to create a slurry, subjecting the slurry to pressure; and allowing the now pressurized slurry to set. Lastly, the invention provides for a method to stabilize liquid waste, comprising supplying a powder containing magnesium, sodium and phosphate in predetermined proportions, mixing said powder with the liquid waste, such as tritium, and allowing the resulting slurry to set.

Wagh, Arun S. (Joliet, IL); Singh, Dileep (Westmont, IL)

1997-01-01T23:59:59.000Z

451

Method for stabilizing low-level mixed wastes at room temperature  

DOE Patents (OSTI)

A method to stabilize solid and liquid waste at room temperature is provided comprising combining solid waste with a starter oxide to obtain a powder, contacting the powder with an acid solution to create a slurry, said acid solution containing the liquid waste, shaping the now-mixed slurry into a predetermined form, and allowing the now-formed slurry to set. The invention also provides for a method to encapsulate and stabilize waste containing cesium comprising combining the waste with Zr(OH){sub 4} to create a solid-phase mixture, mixing phosphoric acid with the solid-phase mixture to create a slurry, subjecting the slurry to pressure; and allowing the now pressurized slurry to set. Lastly, the invention provides for a method to stabilize liquid waste, comprising supplying a powder containing magnesium, sodium and phosphate in predetermined proportions, mixing said powder with the liquid waste, such as tritium, and allowing the resulting slurry to set. 4 figs.

Wagh, A.S.; Singh, D.

1997-07-08T23:59:59.000Z

452

The Committee met in Room 1E-245 of the Forrestal Building,  

U.S. Energy Information Administration (EIA) Indexed Site

COMMITTEE ON ENERGY STATISTICS MEETING FRIDAY NOVEMBER 20, 1998 The Committee met in Room 1E-245 of the Forrestal Building, Department of Energy, 1000 Independence Avenue, S.W., Washington, D.C. at 8:30 a.m., Daniel A. Relles, Chair, presiding. PRESENT: Daniel A. Relles, Chair Carol Gotway Crawford, Vice Chair David R. Bellhouse Charles W. Bischoff Jay Breidt R. Samprit Chatterjee Greta M. Ljung Polly A. Phipps Seymour Sudman ALSO PRESENT: Lynda CarlsonBob Jewett Mary CarlsonRoy Kass Jay CasselberryInderjit Kundra Dave CostelloM.T. Lawrence Ramesh DandekarNancy Leach Stan FreedmanRei-Pyng Lu Dwight FrenchRenee Miller Joan HeinkelLarry Pettis Bill Weinig I-N-D-E-X Page No. Opening Comments from the Chair Dan Relles 3 A New Natural Gas Imports Model for STIFS Presenter, David Costello, (EIA) 4

453

The Committee met in Conference Room 8E-089 in the Forrestal  

U.S. Energy Information Administration (EIA) Indexed Site

THURSDAY THURSDAY APRIL 13, 2000 + + + + + The Committee met in Conference Room 8E-089 in the Forrestal Building at 10th Street and Independence Avenue, S.W., Washington, D.C., at 8:30 a.m., Carol Gotway Crawford, Chair, presiding. PRESENT: CAROL A. GOTWAY CRAWFORD, PhD Chair JAY BREIDT, PhD Member THOMAS G. COWING, PhD Member CALVIN A. KENT, PhD Member W. DAVID MONTGOMERY, PhD Member WILLIAM G. MOSS, PhD Member POLLY A. PHIPPS, PhD Member RANDY R. SITTER, PhD Member ROY WHITMORE, PhD Member JOHNNY BLAIR, PhD Member I-N-D-E-X Page Welcome and Introduction 3 Chairman Crawford Opening Remarks 9 Jay Hakes, Administrator, EIA

454

Unusual Room Temperature Ferromagnetism in Bulk Sintered GaP Doped with Copper  

Science Conference Proceedings (OSTI)

Robust room temperature ferromagnetism is obtained in single phase Gallium Phosphide doped with Cu{sup 2+} prepared by simple solid state reaction route. The saturation magnetization at 300 K is 1.5 times 10{sup -2} emu/g and the coercivity was found to be 125 Oe. A strong ferromagnetic resonance signal confirms the long range magnetic order which persists to temperatures as high as 739 K. X-ray absorption spectroscopy (XAS) indicate that Cu is in a +2 state. Ab initio calculations also show that the ferromagnetic ordering is energetically favorable in Cu doped GaP. When the spin-orbit coupling is included we get an enhanced total magnetic moment of 0.31 muB with a local moment on Cu 0.082 and on P 0.204 mu{sub B}. per atom.

Owens, F. J.; Gupta, A.; Rao, K. V.; Iqbal, Z.; Osorio Guillen, J. M.; Ahuja, R.; Guo, J.-H.

2007-06-01T23:59:59.000Z

455

Energy Savings in Buildings Using Air Movement and Allowing Floating Temperature in Rooms  

E-Print Network (OSTI)

The purpose of the research study was to determine if building loads could be reduced by using an intelligent controller rather than a thermostatic controller to operate heating and air conditioning equipment. In order to switch the equipment on and off at the proper times, the intelligent controller calculated temperature limits using a mathematical procedure that determined the percentage of people who would be comfortable in rooms of the building. Simulations showed the annual cost savings from intelligent controllers ranged from 6 to 37 percent for residences and from 6 to 29 percent for the offices. An ancillary study showed that a ceiling fan provided comfort in a 112 square foot floor area to 85 F and in a 200 to 250 square foot area to 82 F.

Spain, S.

1985-01-01T23:59:59.000Z

456

Conjectured explanation for room-temperature superconductivity in narrow channels in oxidized polypropylene  

SciTech Connect

Two groups of scientists have observed conductivity at least five orders of magnitude higher than that of copper at room temperature in narrow channels perpendicular to surfaces of films in oxidized polypropylene. For pulsed currents, this conductivity starts at a minimum value of applied current, and is destroyed at a current of about 30-60 times this value. Because of the existence of an upper critical current and of the observation that electronic thermal conductivity is negligible in the channels, it is thought that the channels are superconducting. A study is made of the hypothesis that these results are due to enhanced pairing, as first suggested by Parameter, when the drift velocity of current carriers becomes close to the velocity of sound or, in work by Hone and by the present author, to an appropriate phase velocity of optical phonons. Such enhancements can be expected to be larger in quasi-one-dimensional systems. 10 refs.

Eagles, D.M. (NASA Marshall Space Flight Center, Huntsville, AL (United States))

1994-06-01T23:59:59.000Z

457

Experimental Observation of the Inverse Spin Hall Effect at Room Temperature  

SciTech Connect

We observe the inverse spin Hall effect in a two-dimensional electron gas confined in Al-GaAs/InGaAs quantum wells. Specifically, they find that an inhomogeneous spin density induced by the optical injection gives rise to an electric current transverse to both the spin polarization and its gradient. The spin Hall conductivity can be inferred from such a measurement through the Einstein relation and the onsager relation, and is found to have the order of magnitude of 0.5(e{sup 2}/h). The observation is made at the room temperature and in samples with macroscopic sizes, suggesting that the inverse spin Hall effects is a robust macroscopic transport phenomenon.

Liu, Baoli; Shi, Junren; Wang, Wenxin; Zhao, Hongming; Li, Dafang; /Beijing, Inst. Phys.; Zhang, Shoucheng; /Stanford U., Phys. Dept.; Xue, Qikun; Chen, Dongmin; /Beijing, Inst. Phys.

2010-03-16T23:59:59.000Z

458

From molten salts to room temperature ionic liquids: Simulation studies on chloroaluminate systems  

E-Print Network (OSTI)

An interaction potential including chloride anion polarization effects, constructed from first-principles calculations, is used to examine the structure and transport properties of a series of chloroaluminate melts. A particular emphasis was given to the study of the equimolar mixture of aluminium chloride with 1-ethyl-3-methylimidazolium chloride, which forms a room temperature ionic liquid EMI-AlCl 4. The structure yielded by the classical simulations performed within the framework of the polarizable ion model is compared to the results obtained from entirely electronic structure-based simulations: An excellent agreement between the two flavors of molecular dynamics is observed. When changing the organic cation EMI+ by an inorganic cation with a smaller ionic radius (Li+, Na+, K+), the chloroaluminate speciation becomes more complex, with the formation of Al2Cl 7- in small amounts. The calculated transport properties (diffusion coefficients, electrical conductivity and viscosity) of EMI-AlCl4 are in good ag...

Salanne, Mathieu; Seitsonen, Ari P; Madden, Paul A; Kirchner, Barbara; 10.1039/C1FD00053E

2013-01-01T23:59:59.000Z

459

CDZNTE ROOM-TEMPERATURE SEMICONDUCTOR GAMMA-RAY DETECTOR FOR NATIONAL-SECURITY APPLICATIONS.  

Science Conference Proceedings (OSTI)

One important mission of the Department of Energy's National Nuclear Security Administration is to develop reliable gamma-ray detectors to meet the widespread needs of users for effective techniques to detect and identify special nuclear- and radioactive-materials. Accordingly, the Nonproliferation and National Security Department at Brookhaven National Laboratory was tasked to evaluate existing technology and to develop improved room-temperature detectors based on semiconductors, such as CdZnTe (CZT). Our research covers two important areas: Improving the quality of CZT material, and exploring new CZT-based gamma-ray detectors. In this paper, we report on our recent findings from the material characterization and tests of actual CZT devices fabricated in our laboratory and from materials/detectors supplied by different commercial vendors. In particular, we emphasize the critical role of secondary phases in the current CZT material and issues in fabricating the CZT detectors, both of which affect their performance.

CAMARDA,G.S.; BOLOTNIKOV, A.E.; CUI, Y.; HOSSAIN, A.; KOHMAN, K.T.; JAMES, R.B.

2007-05-04T23:59:59.000Z

460

The Committee convened in the Clark Room of the Holiday Inn  

U.S. Energy Information Administration (EIA) Indexed Site

- - - - - - - - - - COMMITTEE ON ENERGY STATISTICS - - - - - MEETING - - - - - FRIDAY, APRIL 26, 1996 The Committee convened in the Clark Room of the Holiday Inn Capitol, 550 C Street, S.W., Washington, D.C., at 9:00 a.m., DR. TIMOTHY D. MOUNT, Chair, presiding. PRESENT: TIMOTHY D. MOUNT, Chair SAMPRIT CHATTERJEE BRENDA G. COX JOHN D. GRACE CALVIN KENT GRETA M. LJUNG RICHARD A. LOCKHART DANIEL A. RELLES BRADLEY O. SKARPNESS G. CAMPBELL WATKINS ALSO PRESENT: RENEE MILLER YVONNE M. BISHOP DIANE LIQUE L.A. PETTIS JAY HAKES JOHN WOOD GORDON M. KAUFMAN ROY KASS NANCY LEACH I-N-D-E-X Introductory Remarks: Announcement of Winners of the Contest on Graphs and Visuals Displays 3 Restructuring the Oil and Gas Crude Reserves Program (Agenda Item 5) Presenter: John Wood, Office of Oil and Gas 8

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

The Committee met in the Clark Room, Holiday Inn Capitol at 550  

U.S. Energy Information Administration (EIA) Indexed Site

PUBLIC MEETING + + + THURSDAY, APRIL 10, 1997 + + + The Committee met in the Clark Room, Holiday Inn Capitol at 550 C Street, S.W., Washington, D.C., at 9:00 a.m., G. Campbell Watkins, Chairman, presiding. PRESENT: G. CAMPBELL WATKINS, Chairman DAVID R. BELLHOUSE CHARLES W. BISCHOFF BRENDA G. COX CAROL A. GOTWAY CRAWFORD CALVIN KENT GRETA M. LJUNG DANIEL A. RELLES BRADLEY O. SKARPNESS PRESENT (Continued): ROY WHITMORE C O N T E N T S PAGE Opening Remarks, Lynda Carlson 10 Update on 1997 Residential Energy Consumption Survey, Mike Laurence 16 The Use of a Variant of Poisson Sampling: Paula Weir 58, 85 David Bellhouse 72 Roy Whitmore 79 Presentation by Administrator Jay Hakes 112 Results of Customer Satisfaction Survey, Colleen Blessing 138 Annual Energy Outlook/Short-term Energy

462

The Committee met in Room 8E089 in the Forrestal Building, 1800  

U.S. Energy Information Administration (EIA) Indexed Site

APRIL 4, 2003 APRIL 4, 2003 + + + + + The Committee met in Room 8E089 in the Forrestal Building, 1800 Independence Avenue, S.W., Washington, D.C., at 8:30 a.m., Jay Breidt, Chair, presiding. PRESENT: F. JAY BREIDT, Chair MARK BERNSTEIN, Committee Member JOHNNY BLAIR, Committee Member JAE EDMONDS, Committee Member MOSHE FEDER, Committee Member JAMES K. HAMMITT, Committee Member NEHA KHANNA, Committee Member WILLIAM G. MOSS, Committee Member NAGARAJ K. NEERCHAL, Committee Member POLLY A. PHIPPS, Committee Member RANDY R. SITTER, Committee Member ALSO PRESENT: GUY CARUSO, Administrator, Energy Information Administration HOWARD GRUENSPECHT, Deputy Administrator, EIA NANCY J. KIRKENDALL, Designated Federal Official BILL WEINIG, EIA CALVIN KENT, Invited Guest CRYSTAL LINKLETTER, Invited Guest

463

Sailing into the Mainstream of Energy and Water Efficiency, Affordably |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sailing into the Mainstream of Energy and Water Efficiency, Sailing into the Mainstream of Energy and Water Efficiency, Affordably Sailing into the Mainstream of Energy and Water Efficiency, Affordably October 13, 2010 - 11:50am Addthis John Lippert I took off work on Friday, September 10, to have a 3-day weekend with my wife visiting a research center in Virginia Beach. After consulting Virginia's green lodging Web site, my wife and I jotted down nearly a dozen participating hotels, motels, and bed and breakfasts not far from the research center. We checked rates and availability and were surprised to find many of the hotels with no vacancies. Little did we know that Virginia Beach was observing September 11th with a parade, and a lot of people were in town. Fortunately, the one place both my wife and I liked had

464

SRNL PHASE II SHELF LIFE STUDIES - SERIES 1 ROOM TEMPERATURE AND HIGH RELATIVE HUMIDITY  

SciTech Connect

The Savannah River National Laboratory (SRNL) Phase II, Series 1 shelf-life corrosion testing for the Department of Energy Standard 3013 container is presented and discussed in terms of the localized corrosion behavior of Type 304 stainless steel in contact with moist plutonium oxide and chloride salt mixtures and the potential impact to the 3013 inner container. This testing was designed to address the influence of temperature, salt composition, initial salt moisture, residual stress and type of oxide/salt contact on the relative humidity inside a 3013 container and the initiation and propagation of localized corrosion, especially stress corrosion cracking. The integrated plan is being conducted by Los Alamos National Laboratory and SRNL. SRNL is responsible for conducting a corrosion study in small scale vessels containing plutonium oxide and chloride salts under conditions of humidity, temperature and oxide/salt compositions both within the limits of 3013 storage conditions as well as beyond the 3013 storage requirements to identify margins for minimizing the initiation of stress corrosion cracking. These worst case conditions provide data that bound the material packaged in 3013 containers. Phase I of this testing was completed in 2010. The Phase II, Series 1 testing was performed to verify previous results from Phase I testing and extend our understanding about the initiation of stress corrosion cracking and pitting that occur in 304L under conditions of room temperature, high humidity, and a specific plutonium oxide/salt chemistry. These results will aid in bounding the safe storage conditions of plutonium oxides in 3013 containers. A substantial change in the testing was the addition of the capability to monitor relative humidity during test exposure. The results show that under conditions of high initial moisture ({approx}0.5 wt%) and room temperature stress corrosion cracking occurred in 304L teardrop coupons in contact with the oxide/salt mixture at times as short as 85 days. In all cases, the cracking appeared to be associated with pitting or localized general corrosion. Crack initiation at other sites, such as surface imperfections or inclusions, cannot be excluded. Cracks appear in most cases to initiate through an intergranular mode and transition to a transgranular mode.

Mickalonis, J.; Duffey, J.

2012-09-12T23:59:59.000Z

465

Human Factors Guidance for Control Room and Digital Human-System Interface Design and Modification: Guidelines for Planning, Specifi cation, Design, Licensing, Implementation, Training, Operation, and Maintenance  

Science Conference Proceedings (OSTI)

Operators of nuclear power plants face a significant challenge designing and modifying control rooms that will be produced at various stages of instrumentation and control modernization. This report provides guidance on planning, specifying, designing, implementing, operating, maintaining, and training for modernized control rooms and digital human-system interfaces. Much of the guidance also will support new plant control rooms. This report also presents detailed information and guidelines on specific t...

2004-11-29T23:59:59.000Z

466

Absence of molecular deuterium dissociation during room-temperature permeation into polystyrene ICF target shells  

DOE Green Energy (OSTI)

Polystyrene microshells filled with deuterium and tritium gas are important target shells for inertially confined fusion (ICF) and are particularly promising for target containing spin-polarized hydrogens fuels. A currently active approach to the latter uses polarized D in HD, in a method which requires preservation of the high purity of the initially prepared HD (very low specified H{sub 2} and D{sub 2} concentrations). This would not be possible if dissociation should occur during permeation into the target shells. We have thus tested polystyrene shells using a novel method which employs very pure polystyrene shells using a novel method which employs very pure ortho-D{sub 2} as the test gas. An upper limit of 6 {times} 10{sup {minus}4} was deduced for the dissociation of D{sub 2} upon room temperature permeation through an approximately 8 um wall of polystyrene, clearing the way for use of polystyrene target shells for ICF fusion experiments with spin-polarized hydrogens fuels. 19 refs., 1 fig.

Honig, A.; Alexander, N.; Fan, Q. (Syracuse Univ., NY (USA). Dept. of Physics); Gram, R.; Kim, H. (Rochester Univ., NY (USA). Lab. for Laser Energetics)

1991-01-01T23:59:59.000Z

467

Benzyl-Functionalized Room Temperature Ionic Liquids for CO2/N2 Separation  

Science Conference Proceedings (OSTI)

In this work, three classes of room temperature ionic liquids (RTILs), including imidazolium, pyridinium, and pyrrolidinium ionic liquids with a benzyl group appended to the cation, were synthesized and tested for their performance in separating CO{sub 2} and N{sub 2}. All RTILs contained the bis(trifluoromethylsulfonyl)imide anion, permitting us to distinguish the impact of the benzyl moiety attached to the cation on gas separation performance. In general, the attachment of the benzyl group increased the viscosity of the ionic liquid compared with the unfunctionalized analogs and decreased the CO{sub 2} permeability. However, all of the benzyl-modified ionic liquids exhibited enhanced CO{sub 2}/N{sub 2} selectivities compared with alkyl-based ionic liquids, with values ranging from 22.0 to 33.1. In addition, CO{sub 2} solubilities in the form of Henry's constants were also measured and compared with unfunctionalized analogs. Results of the membrane performance tests and CO{sub 2} solubility measurements demonstrate that the benzyl-functionalized RTILs have significant potential for use in the separation of carbon dioxide from combustion products.

Mahurin, Shannon Mark [ORNL; Dai, Thomas N [ORNL; Yeary, Joshua S [ORNL; Luo, Huimin [ORNL; Dai, Sheng [ORNL

2011-01-01T23:59:59.000Z

468

REVIEW Of COMPUTERIZED PROCEDURE GUIDELINES FOR NUCLEAR POWER PLANT CONTROL ROOMS  

SciTech Connect

Computerized procedures (CPs) are recognized as an emerging alternative to paper-based procedures for supporting control room operators in nuclear power plants undergoing life extension and in the concept of operations for advanced reactor designs. CPs potentially reduce operator workload, yield increases in efficiency, and provide for greater resilience. Yet, CPs may also adversely impact human and plant performance if not designed and implemented properly. Therefore, it is important to ensure that existing guidance is sufficient to provide for proper implementation and monitoring of CPs. In this paper, human performance issues were identified based on a review of the behavioral science literature, research on computerized procedures in nuclear and other industries, and a review of industry experience with CPs. The review of human performance issues led to the identification of a number of technical gaps in available guidance sources. To address some of the gaps, we developed 13 supplemental guidelines to support design and safety. This paper presents these guidelines and the case for further research.

David I Gertman; Katya Le Blanc; Ronald L Boring

2011-09-01T23:59:59.000Z

469

Room Temperature Control During Season Switchover with Single Duct Variable Air Volume System Without Reheat  

E-Print Network (OSTI)

The Langford “A” building houses the College of Architecture on TAMU campus. There are ten singleduct variable air volume (VAV) air-handling units (AHUs) without reheat serving the building. The local pneumatic thermostats modulate the dampers of VAV boxes to maintain room temperature at their setpoints. The thermostat action is switched from direct acting (DA) to reverse acting (RA) when the season changes from fall to winter and vice versa from winter to spring, based on the out side air temperature, when season changes. This results in various parts of the building ether too cold or too hot during the season change. This paper presents that the thermostat action will be switched according to cooling loads or discharge air temperature, instead of outside air temperature. For the interior zone, thermostat action does not need to be switched at all. The comfort is improved and savings is achieved by the new control scheme. Because some air-handling units (AHUs) serve both interior and exterior zones, this system never worked as intended. The system must be modified to have zone reheat and the AHUs discharge air temperature is set below dew point for humidity control.

Liu, C.; Deng, S.; Claridge, D. E.; Turner, W. D.; Bruner, H.

2003-01-01T23:59:59.000Z

470

Impact Testing of Stainless Steel Material at Room and Elevated Temperatures  

SciTech Connect

Stainless steels are used for the construction of numerous spent nuclear fuel or radioactive material containers that may be subjected to high strains and moderate strain rates during accidental drop events. Mechanical characteristics of these base materials and their welds under dynamic loads in the strain rate range of concern are not well documented. However, three previous papers [1, 2, 3] reported on impact testing and analysis results performed at the Idaho National Laboratory using 304/304L and 316/316L stainless steel base material specimens that began the investigation of these characteristics. The goal of the work presented herein is to add the results of additional tensile impact testing for 304/304L and 316/316L stainless steel material specimens. Utilizing a drop-weight impact test machine and 1/4-inch to 1/2-inch thick dog-bone shaped test specimens, additional tests achieved target strain rates of 5, 10, and 22 per second at room temperature, 300, and 600 degrees Fahrenheit. Elevated true stress-strain curves for these materials at each designated strain rate and temperature are presented herein.

Dana K. Morton; Spencer D. Snow; Tom E. Rahl; Robert K. Blandford

2007-07-01T23:59:59.000Z

471

Room temperature green light emission from nonpolar cubic InGaN/GaN multi-quantum-wells  

E-Print Network (OSTI)

Room temperature green light emission from nonpolar cubic InGaN/GaN multi-quantum-wells Shunfeng Li Cubic InGaN/GaN multi-quantum-wells MQWs with high structural and optical quality are achieved by utilizing freestanding 3C-SiC 001 substrates and optimizing InGaN quantum well growth. Superlattice peaks up

As, Donat Josef

472

How the Number and Placement of Sensors Controlling Room Air Distribution Systems Affect Energy Use and Comfort  

E-Print Network (OSTI)

This study assesses the impact of sensor number and placement on the energy needed to condition a typical office using several likely variants of an underfloor air distribution system (UFAD). The study uses an empirical-based room stratification model developed from full-scale tests of UFAD systems. Annual energy consumption is calculated for an interior zone using outside air temperature bin data. The comfort criteria are taken from ASHRAE standard 55-92. The simulations indicate that there are benefits derived from using more than one temperature sensor to control conditions in the occupied zone of a room. Among these are: 1. By adjusting both supply air temperature and volume to maintain the maximum allowable thermal gradient in the occupied (lower) part of the room, an optimal supply air condition can reduce energy use (relative to the best arrangement of a single sensor) while maintaining comfort; 2. Discomfort caused by stratification can be detected by having one of the sensors located at foot level; 3. For the simulated UFAD interior zone of a typical office building in Sacramento, an overall energy saving of 8%/24% (VAV/CAV respectively) can be achieved when two sensors as opposed to one are used to control room conditions.

Wang, D.; Arens, E.; Webster, T.; Shi, M.

2002-01-01T23:59:59.000Z

473

Room-temperature electroluminescence from germanium in an Al0.3Ga0.7As/Ge heterojunction  

E-Print Network (OSTI)

.7As/Ge heterojunction light-emitting diode without any complicated manipulation for alternating. ©2012 Optical Society of America OCIS codes: (230.3670) Light-emitting diodes; (230.3990) Micro. Vuckovi, and Y. Nishi, "Room temperature 1.6 microm electroluminescence from Ge light emitting diode on Si

Kolner, Brian H.

474

Estimation of Thermal Resistance from Room Temperature Electrical Resistance Measurements for Different LHC Beam Screen Support Systems  

E-Print Network (OSTI)

In this note the thermal resistance between the LHC beam screen and cold bore is estimated from room temperature electrical resistance measurements. The results indicate that the beam screen without supports should have a comparable, if not better, thermal performance than the one with the existing spring supports. This prediction from electrical resistance measurements is confirmed by recent preliminary thermal measurements.

Jenninger, B

1999-01-01T23:59:59.000Z

475

Buildings Energy Data Book  

Buildings Energy Data Book (EERE)

3.1 Commercial Sector Energy Consumption 3.1 Commercial Sector Energy Consumption 3.2 Commercial Sector Characteristics 3.3 Commercial Sector Expenditures 3.4 Commercial Environmental Emissions 3.5 Commercial Builders and Construction 3.6 Office Building Markets and Companies 3.7 Retail Markets and Companies 3.8 Hospitals and Medical Facilities 3.9 Educational Facilities 3.10 Hotels/Motels 4Federal Sector 5Envelope and Equipment 6Energy Supply 7Laws, Energy Codes, and Standards 8Water 9Market Transformation Glossary Acronyms and Initialisms Technology Descriptions Building Descriptions Other Data Books Biomass Energy Transportation Energy Power Technologies Hydrogen Download the Entire Book Skip down to the tables Chapter 3 focuses on energy use in the commercial sector. Section 3.1 covers primary and site energy consumption in commercial buildings, as well as the delivered energy intensities of various building types and end uses. Section 3.2 provides data on various characteristics of the commercial sector, including floorspace, building types, ownership, and lifetimes. Section 3.3 provides data on commercial building expenditures, including energy prices. Section 3.4 covers environmental emissions from the commercial sector. Section 3.5 briefly addresses commercial building construction and retrofits. Sections 3.6, 3.7, 3.8, 3.9, and 3.10 provide details on select commercial buildings types, specifically office and retail space, medical facilities, educational facilities, and hotels and motels.

476

THURSDAY MORNING, 3 JULY 2008 ROOM 242B, 8:00 A.M. TO 12:00 NOON Session 4aAAa  

E-Print Network (OSTI)

Design Presentations: Tuesday, April 21, 2009 Time: 3:00-4:00 p.m. Room: 214 EERC Title: Stirling Engine

477

Ionic liquid pretreatment of poplar wood at room temperature: swelling and incorporation of nanoparticles  

DOE Green Energy (OSTI)

Lignocellulosic biomass represents a potentially sustainable source of liquid fuels and commodity chemicals. It could satisfy the energy needs for transportation and electricity generation, while contributing substantially to carbon sequestration and limiting the accumulation of greenhouse gases in the atmosphere. Potential feedstocks are abundant and include crops, agricultural wastes, forest products, grasses, and algae. Among those feedstocks, wood is mainly constituted of three components: cellulose, hemicellulose, and lignin. The conversion process of lignocellulosic biomass typically consists of three steps: (1) pretreatment; (2) hydrolysis of cellulose and hemicellulose into fermentable sugars; and (3) fermentation of the sugars into liquid fuels (ethanol) and other commodity chemicals. The pretreatment step is necessary due to the complex structure of the plant cell wall and the chemical resistance of lignin. Most current pretreatments are energy-intensive and/or polluting. So it is imperative to develop new pretreatments that are economically viable and environmentally friendly. Recently, ionic liquids have attracted considerable interest, due to their ability to dissolve biopolymers, such as cellulose, lignin, native switchgrass, and others. Ionic liquids are also considered green solvents, since they have been successfully recycled at high yields for further use with limited efficiency loss. Also, a few microbial cellulases remain active at high ionic liquid concentration. However, all studies on the dissolution of wood in ionic liquids have been conducted so far at high temperatures, typically above 90 C. Development of alternative pretreatments at room temperature is desirable to eliminate the additional energy cost. In this study, thin sections of poplar wood were swollen at room temperature by a 3 h ionic liquid (1-ethyl-3-methylimidazolium acetate or EMIMAc) pretreatment. The pretreated sample was then exposed to an aqueous suspension of nanoparticles that resulted in the sample contraction and the deposition of nanoparticles onto the surface and embedded into the cell wall. To date, both silver and gold particles ranging in size from 40-100 nm have been incorporated into wood. Penetration of gold nanoparticles of 100 nm diameter in the cell walls was best confirmed by near-infrared confocal Raman microscopy, since the deposition of gold nanoparticles induces a significant enhancement of the Raman signal from the wood in their close proximity, an enhancement attributed to the surface-enhanced Raman effect (SERS). After rinsing with water, scanning electron microscopy (SEM) and Raman images of the same areas show that most nanoparticles remained on the pretreated sample. Raman images at different depths reveal that a significant number of nanoparticles were incorporated into the wood sample, at depths up to 4 {micro}m, or 40 times the diameter of the nanoparticles. Control experiments on an untreated wood sample resulted in the deposition of nanoparticles only at the surface and most nanoparticles were removed upon rinsing. This particle incorporation process enables the development of new pretreatments, since the nanoparticles have a high surface-to-volume ratio and could be chemically functionalized. Other potential applications for the incorporated nanoparticles include isotope tracing, catalysis, imaging agents, drug-delivery systems, energy-storage devices, and chemical sensors.

Lucas, Marcel [Los Alamos National Laboratory; Macdonald, Brian A [Los Alamos National Laboratory; Wagner, Gregory L [Los Alamos National Laboratory; Joyce, Steven A [Los Alamos National Laboratory; Rector, Kirk D [Los Alamos National Laboratory

2010-01-01T23:59:59.000Z

478

Minimally Invasive Catheter Procedures to Assist Complicated Pacemaker Lead Extraction and Implantation in the Operating Room  

SciTech Connect

We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 {+-} 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thus required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.

Kroepil, Patric; Lanzman, Rotem S., E-mail: rotemshlomo@yahoo.de; Miese, Falk R.; Blondin, Dirk [University Hospital Duesseldorf, Department of Radiology (Germany); Winter, Joachim [University Hospital Duesseldorf, Department of Cardiovascular Surgery (Germany); Scherer, Axel; Fuerst, Guenter [University Hospital Duesseldorf, Department of Radiology (Germany)

2011-04-15T23:59:59.000Z

479

Advanced Biofuels Workshop U.S. Energy Information Administration 1000 Independence Ave. SW, Room 2E-069 Washington, DC 20585  

Gasoline and Diesel Fuel Update (EIA)

U.S. Energy Information Administration 1000 Independence Ave. SW, Room 2E-069 Washington, DC 20585 U.S. Energy Information Administration 1000 Independence Ave. SW, Room 2E-069 Washington, DC 20585 August 1, 2012 Presenter Bios (Arranged in presentation order) Anthony Radich Tony Radich is an economist with the Energy Information Administration. He is currently a member of the Biofuels and Emerging Technologies Team in the Petroleum, Natural Gas and Biofuels Analysis group of the Office of Energy Analysis. Dr. Radich has worked on biofuels issues since he joined EIA in 2001. He developed the cost models for the production of ethanol and biodiesel, the National Energy Modeling System, which is used to produce the EIA Annual Energy Outlook. He has served as a contributing author to numerous EIA publications, including the Annual Energy Outlook and the Short-Term

480

PHYSICAL FIDELITY CONSIDERATIONS FOR NRC ADVANCED REACTOR CONTROL ROOM TRAINING SIMULATORS USED FOR INSPECTOR/EXAMINER TRAINING  

Science Conference Proceedings (OSTI)

This paper describes research into the physical fidelity requirements of control room simulators to train U.S. Nuclear Regulatory Commission (NRC) staff for their duties as inspectors and license examiners for next-generation nuclear power plants. The control rooms of these power plants are expected to utilize digital instrumentation and controls to a much greater extent than do current plants. The NRC is assessing training facility needs, particularly for control room simulators, which play a central role in NRC training. Simulator fidelity affects both training effectiveness and cost. Research has shown high simulation fidelity sometimes positively affects transfer to the operational environment but sometimes makes no significant difference or actually impedes learning. The conditions in which these different effects occur are often unclear, especially for regulators (as opposed to operators) about whom research is particularly sparse. This project developed an inventory of the tasks and knowledges, skills, and abilities that NRC regulators need to fulfill job duties and used expert panels to characterize the inventory items by type and level of cognitive/behavioral capability needed, difficulty to perform, importance to safety, frequency of performance, and the importance of simulator training for learning these capabilities. A survey of current NRC staff provides information about the physical fidelity of the simulator on which the student trained to the control room to which the student was assigned and the effect lack of fidelity had on learning and job performance. The study concludes that a high level of physical fidelity is not required for effective training of NRC staff.

Branch, Kristi M.; Mitchell, Mark R.; Miller, Mark; Cochrum, Steven

2010-11-07T23:59:59.000Z

Note: This page contains sample records for the topic "hotel rooms motel" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Techno-Economic Analysis of Indian Draft Standard Levels for RoomAir Conditioners  

SciTech Connect

The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency. In support of BEE's refrigerator program, Lawrence Berkeley National Laboratory (LBNL) produced an analysis of national impacts of standards in collaboration with the Collaborative Labeling and Standards Program (CLASP). That analysis drew on LBNL's experience with standards programs in the United States, as well as many other countries. Subsequently, as part of the process for setting optimal levels for air conditioner regulations, CLASP commissioned LBNL to provide support to BEE in the form of a techno-economic evaluation of air conditioner efficiency technologies. This report describes the methodology and results of this techno-economic evaluation. The analysis consists of three components: (1) Cost effectiveness to consumers of efficiency technologies relative to current baseline. (2) Impacts on the current market from efficiency regulations. (3) National energy and financial impacts. The analysis relied on detailed and up-to-date technical data made available by BEE and industry representatives. Technical parameters were used in conjunction with knowledge about air conditioner use patterns in the residential and commercial sectors, and prevailing marginal electricity prices, in order to give an estimate of per-unit financial impacts. In addition, the overall impact of the program was evaluated by combining unit savings with market forecasts in order to yield national impacts. LBNL presented preliminary results of these analyses in May 2006, at a meeting of BEEs Technical Committee for Air Conditioners. This meeting was attended by a wide array of stakeholder, including industry representatives, engineers and consumer advocates. Comments made by stakeholders at this meeting are incorporated into the final analysis presented in this report. The current analysis begins with the Rating Plan drafted by BEE in 2006, along with an evaluation of the market baseline according to test data submitted by manufacturers. MEPS, label rating levels, and baseline efficiencies are presented in Section 2. First, we compare Indian MEPS with current standards in other countries, and assess their relative stringency. Baseline efficiencies are then used to estimate the fraction of models likely to remain on the market at each phase of the program, and the impact on market-weighted efficiency levels. Section 3 deals with cost-effectiveness of higher efficiency design options. The cost-benefit analysis is grounded in technical parameters provided by industry representatives in India. This data allows for an assessment of financial costs and benefits to consumers as a result of the standards and labeling program. A Life-Cycle Cost (LCC) calculation is used to evaluate the impacts of the program at the unit level, thus providing some insight into the appropriateness of the levels chosen, and additional opportunities for further ratcheting. In addition to LCC, we also calculate payback periods, cost of conserved energy (CCE), and return on investment (ROI). Finally, Section 4 covers national impacts. This is an extension of unit level estimates in the two previous sections. Extrapolation to the national level depends on a forecast of air conditioner purchases (shipments), which we describe here. Following the cost-benefit analysis, we construct several efficiency scenarios including the BEE plan, but also considering further potential for efficiency improvement. These are combined with shipments through a stock accounting model in order to forecast air conditioner energy consumption

McNeil, Michael A.; Iyer, Maithili

2007-03-01T23:59:59.000Z

482

Digital Full-Scope Simulation of a Conventional Nuclear Power Plant Control Room, Phase 2: Installation of a Reconfigurable Simulator to Support Nuclear Plant Sustainability  

SciTech Connect

The U.S. Department of Energy’s Light Water Reactor Sustainability program has developed a control room simulator in support of control room modernization at nuclear power plants in the U.S. This report highlights the recent completion of this reconfigurable, full-scale, full-scope control room simulator buildout at the Idaho National Laboratory. The simulator is fully reconfigurable, meaning it supports multiple plant models developed by different simulator vendors. The simulator is full-scale, using glasstop virtual panels to display the analog control boards found at current plants. The present installation features 15 glasstop panels, uniquely achieving a complete control room representation. The simulator is also full-scope, meaning it uses the same plant models used for training simulators at actual plants. Unlike in the plant training simulators, the deployment on glasstop panels allows a high degree of customization of the panels, allowing the simulator to be used for research on the design of new digital control systems for control room modernization. This report includes separate sections discussing the glasstop panels, their layout to mimic control rooms at actual plants, technical details on creating a multi-plant and multi-vendor reconfigurable simulator, and current efforts to support control room modernization at U.S. utilities. The glasstop simulator provides an ideal testbed for prototyping and validating new control room concepts. Equally importantly, it is helping create a standardized and vetted human factors engineering process that can be used across the nuclear industry to ensure control room upgrades maintain and even improve current reliability and safety.

Ronald L. Boring; Vivek Agarwal; Kirk Fitzgerald; Jacques Hugo; Bruce Hallbert

2013-03-01T23:59:59.000Z

483

Room Temperature ppb Level Chlorine Gas Sensor Based on Copper (II) 1, 4, 8, 11, 15, 18, 22, 25-octabutoxy-29 H, 31 H-phthalocyanine Films  

SciTech Connect

Spin coating technique has been used to fabricate room temperature chlorine gas sensor based on copper (II) 1, 4, 8, 11, 15, 18, 22, 25-octabutoxy-29 H, 31 H-phthalocyanine (CuPc(OBu){sub 8}) films. Gas sensor shows a response of 185% to few parts per billion level of Cl{sub 2} gas with response time of 9.5 minutes at room temperature. The interactions between sensor and analytes followed first order kinetics with rate constant 0.01{<=}k{<=}0.02. The chemiresistive sensor showed very good stability at room temperature over a long period of time.

Bedi, R. K.; Saini, Rajan; Mahajan, Aman [Material Science Laboratory, Department of PhysicsGuru Nanak Dev University, Amritsar-143005 (India)

2010-12-01T23:59:59.000Z

484

CAR Demo 3.0: Community Activity Room Visualization of Probabilistic Reliability Contours for Operator Guidance, Version 3.0  

Science Conference Proceedings (OSTI)

The Community Activity Room (CAR) Version 3.0 software visualizes the probabilistic reliability index by means of color bands in the two-dimensional operating space of a power system. EPRI developed the concept of the CAR software in the spring of 2002. It was implemented in the CAR Painter software. A demonstration software (version 1.0) was issued in September 2002. Version 2.0 was issued in March 2004. The CAR Painter includes a 2D and a 3D visualization mode. CAR 3.0 can visualize the probabilistic r...

2004-12-08T23:59:59.000Z

485

Deployment of a Full-Scope Commercial Nuclear Power Plant Control Room Simulator at the Idaho National Laboratory  

Science Conference Proceedings (OSTI)

The INL operates the HSSL to conduct research in the design and evaluation of advanced reactor control rooms, integration of intelligent support systems to assist operators, development and assessment of advanced human performance models, and visualizations to assess advanced operational concepts across various infrastructures. This advanced facility consists of a reconfigurable simulator and a virtual reality capability (known as the Computer-Aided Virtual Environment (CAVE)) (Figure 2). It supports human factors research, including human-in-the-loop performance, HSI, and analog and digital hybrid control displays. It can be applied to the development and evaluation of control systems and displays for complex systems such as existing and advanced NPP control rooms, command and control systems, and advance emergency operations centers. The HSSL incorporates a reconfigurable control room simulator, which is currently housed in the Center for Advanced Energy Studies (CAES), a joint venture of the DOE and the Idaho University System. The simulator is a platform- and plant-neutral environment intended for full-scope and part-task testing of operator performance in various control room configurations. The simulator is not limited to a particular plant or even simulator architecture. It can support engineering simulator platforms from multiple vendors using digital interfaces. Due to its ability to be reconfigured, it is possible to switch the HSI - not just to digital panels but also to different control modalities such as those using greater plant automation or intelligent alarm filtering. The simulator currently includes three operator workstations, each capable of driving up to eight 30-inch monitors. The size and number of monitors varies depending on the particular front-end simulator deployed for a simulator study. These operator workstations would typically be used for the shift supervisor or senior reactor operator, reactor operator, and assistant reactor operator in current US NPPs. In addition to the three workstations, information can be shared between the workstations and further displayed on a large-screen overview display or a panel mimic. An 82-inch high-definition display is commonly used for the overview display.

Ronald Boring; Julius Persensky; Kenneth Thomas

2011-09-01T23:59:59.000Z

486

Draft audit report, human factors engineering control room design review: Saint Lucie Nuclear Power Plant, Unit No. 2  

SciTech Connect

A human factors engineering preliminary design review of the Saint Lucie Unit 2 control room was performed at the site on August 3 through August 7, 1981. This design review was carried out by a team from the Human Factors Engineering Branch, Division of Human Factors Safety. This report was prepared on the basis of the HFEB's review of the applicant's Preliminary Design Assessment and the human factors engineering design review/audit performed at the site. The review team included human factors consultants from BioTechnology, Inc., Falls Church, Virginia, and from Lawrence Livermore National Laboratory (University of California), Livermore, California.

Peterson, L.R.; Lappa, D.A.; Moore, J.W.

1981-09-03T23:59:59.000Z

487

Buildings Energy Data Book: 8.3 Commercial Sector Water Consumption  

Buildings Energy Data Book (EERE)

5 5 Normalized Annual End Uses of Water in Select Hotels in Western United States (Gallons per Room per Year) (1) Fixture/End Use Bathtub (2) Faucets Showers Toilets Leaks Laundry Ice making (3) Other/misc. indoor Total Indoor Use Number of Rooms Logged average daily use, kgal: Peak instantaneous demand, gpm: Benchmarking Values for Hotels N Indoor Use, gal./day/occupied room 98 Cooling Use, gal./year/occupied room 97 Note(s): Source(s): 25th Percentile of Users 60 - 115 7,400 - 41,600 Based on four budget hotels and one luxury hotel. Three budget hotels in Southern California, one in Phoenix, AZ. Luxury hotel in Los Angeles, CA. 1) Water use data for the buildings was collected over a few days. Estimates of annual use were created by accounting for seasonal use and other variables, billing data, and interviews with building managers. 2) Based on one hotel. 3) Based on three hotels. 5) The

488

UWM-CBU Concrete Materials Technology Series Program No. 72 Construction Demonstration for Use of Residuals and Reject Fibers  

E-Print Network (OSTI)

-Products Utilization, Milwaukee, WI August 28, 2008, Brookfield, WI Best Western Midway Hotel-Brookfield, 1005 S-Products Utilization NONPROFIT ORGANIZATION 3200 North Cramer Street, Room W309 U.S. POSTAGE P. O. Box 784 PAID will be presented. #12;PROGRAM August 28, 2008 Best Western Midway Hotel-Brookfield, 1005 S. Moorland Rd. (I-94

Saldin, Dilano

489

A constraint programming agent for automated trading  

E-Print Network (OSTI)

), and out-flight (mandatory), rooms in one hotel during the nights on location (mandatory) and entertainment, and bonuses for the choice of hotel and entertainment tickets. All the goods to be bundled have to be acquired distributing goods to clients that hold non-additive utilities. As such it can be contrasted with other

Janson, Sverker

490

Sem-Fit: A semantic based expert system to provide recommendations in the tourism domain  

Science Conference Proceedings (OSTI)

The hotel industry is one of the leading stakeholders in the tourism sector. In order to reduce the traveler's cost of seeking accommodations, enforce the return ratio efficiency of guest rooms and enhance total operating performance, evaluating and ... Keywords: Fuzzy logic, Hotels, Recommender systems, Semantic labeling, Semantic technologies

Ángel García-Crespo; José Luis López-Cuadrado; Ricardo Colomo-Palacios; Israel González-Carrasco; Belén Ruiz-Mezcua

2011-09-01T23:59:59.000Z

491

The Committee met at 8:30 a.m. in Room 8E-089 of the Forrestal  

U.S. Energy Information Administration (EIA) Indexed Site

FALL MEETING FALL MEETING THURSDAY, NOVEMBER 2, 2000 + + + + + The Committee met at 8:30 a.m. in Room 8E-089 of the Forrestal Building, U.S. Department of Energy, 1000 Independence Avenue, S.W., Washington, D.C., Dr. Carol A. Gotway Crawford, Chair, presiding. PRESENT: CAROL A. GOTTWAY CRAWFORD, PhD Chair JOHNNY BLAIR Guest F. JAY BREIDT, PhD Member THOMAS C. COWING, PhD Member JAMES K. HAMMITT, PhD Member NICOLAS HENGARTNER Guest CALVIN A. KENT, PhD Member W. DAVID MONTGOMERY, PhD Member WILLIAM G. MOSS, PhD Member POLLY A. PHIPPS, PhD Member RANDY R. SITTER, PhD Member ROY W. WHITMORE, PhD Member

492

Hydrogen incorporation induced metal-semiconductor transition in ZnO:H thin films sputtered at room temperature  

Science Conference Proceedings (OSTI)

The room temperature deposited ZnO:H thin films having high conductivity of 500 Ohm-Sign {sup -1} cm{sup -1} and carrier concentration reaching 1.23 Multiplication-Sign 10{sup 20} cm{sup -3} were reactively sputter deposited on glass substrates in the presence of O{sub 2} and 5% H{sub 2} in Ar. A metal-semiconductor transition at 165 K is induced by the increasing hydrogen incorporation in the films. Hydrogen forms shallow donor complex with activation energy of {approx}10-20 meV at oxygen vacancies (V{sub O}) leading to increase in carrier concentration. Hydrogen also passivates V{sub O} and V{sub Zn} causing {approx}4 times enhancement of mobility to 25.4 cm{sup 2}/V s. These films have potential for use in transparent flexible electronics.

Singh, Anil; Chaudhary, Sujeet; Pandya, D. K. [Thin Film Laboratory, Department of Physics, Indian Institute of Technology Delhi, New Delhi 110016 (India)] [Thin Film Laboratory, Department of Physics, Indian Institute of Technology Delhi, New Delhi 110016 (India)

2013-04-29T23:59:59.000Z

493

Synthesis of Room-Temperature Ferromagnetic Cr-doped TiO?(110) Rutile Single Crystals using Ion Implantation  

SciTech Connect

Ferromagnetic Cr-doped rutile TiO? single crystals were synthesized by high-temperature ion implantation. The associated structural, compositional and magnetic properties were studied by x-ray photoelectron spectroscopy, Rutherford backscattering spectrometry, proton induced x-ray emission, x-ray diffraction, Cr K- and L-shell near-edge x-ray absorption spectroscopy, and vibrating sample magnetometry. Cr was distributed uniformly to the depth of about 300 nm with an average concentration of ~1 at. %. The samples are semiconducting and ferromagnetic as implanted, with a saturation magnetization of 0.29???B/Cr atom at room temperature. Cr is in a formal oxidation state of +3 throughout the implanted region, and no CrO? is detected.

Shutthanandan, V.; Thevuthasan, Suntharampillai; Droubay, Timothy; Heald, Steve M.; Engelhard, Mark H.; McCready, David E.; Chambers, Scott A.; Nachimuthu, Ponnusamy; Mun, B. S.

2006-01-01T23:59:59.000Z

494

Advanced Biofuels Workshop U.S. Energy Information Administration 1000 Independence Ave. SW, Room 2E-069 Washington, DC 20585  

Gasoline and Diesel Fuel Update (EIA)

Advanced Biofuels Workshop Advanced Biofuels Workshop U.S. Energy Information Administration 1000 Independence Ave. SW, Room 2E-069 Washington, DC 20585 August 1, 2012 Contact Information Hosts: Mindi Farber-DeAnda Team Lead, Energy Information Administration, Biofuels and Emerging Technologies Mindi.Farber-DeAnda@eia.gov 202-586-6419 Vishakh Mantri, Ph.D, P.E. Chemical Engineer, Energy Information Administration, Biofuels and Emerging Technologies Team Vishakh.Mantri@eia.gov 202-586-4815 Presenters Biofuels Year in Review Anthony Radich Analyst, Energy Information Administration Anthony.Radich@eia.gov 202-586-0504 Biofuels Outlook Terrence Higgins Hart Downstream Energy Services thiggins@hartenergy.com 703-891-4815 703-891-4815 Sustainability of Biofuels

495

Dynamic polarization of single nuclear spins by optical pumping of NV color centers in diamond at room temperature  

E-Print Network (OSTI)

We report a versatile method to efficiently polarize single nuclear spins in diamond, which is based on optical pumping of a single NV color center and mediated by a level-anti crossing in its excited state. A nuclear spin polarization higher than 98% is achieved at room temperature for the 15N nuclear spin associated to the NV center, corresponding to $\\mu$K effective nuclear spin temperature. We then show simultaneous deterministic initialization of two nuclear spins (13C and 15N) in close vicinity to a NV defect. Such robust control of nuclear spin states is a key ingredient for further scaling up of nuclear-spin based quantum registers in diamond.

V. Jacques; P. Neumann; J. Beck; M. Markham; D. Twitchen; J. Meijer; F. Kaiser; G. Balasubramanian; F. Jelezko; J. Wrachtrup

2008-08-01T23:59:59.000Z

496

Upgrading of the Air-conditioning of the Computer Room in the Computer Centre for the LHC era  

E-Print Network (OSTI)

Built in the beginning of 1970's, the Computer Centre air-conditioning and cooling systems were designed to be modular and easily adaptable to the unpredictable future needs of computing. The infrastructure of LHC-computing that will be housed in the existing Computer Room with its five Computing farms and over 11000 PC's increases the requirements of cooling and air-conditioning power to a new level. The nominal thermal loads from the equipment rise from the current design maximum of 1MW to estimated maximum of 2MW in the future. This paper presents calculations and proposes solutions to meet the new nominal requirements. The air-conditioning system must also be able to cope with a situation of power cut in the main supply. A calculation of the temperature evolution during the power cut and a justified operation strategy for this scenario is also presented.

Lindroos, J

2001-01-01T23:59:59.000Z