Powered by Deep Web Technologies
Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

A Realistic Hot Water Draw Specification for Rating Solar Water...  

NLE Websites -- All DOE Office Websites (Extended Search)

thornton@tess-inc.com ABSTRACT In the United States, annual performance ratings for solar water heaters are simulated, using TMY weather and specified water draw. Bias...

2

Realistic Hot Water Draw Specification for Rating Solar Water Heaters: Preprint  

DOE Green Energy (OSTI)

In the United States, annual performance ratings for solar water heaters are simulated, using TMY weather and specified water draw. A more-realistic ratings draw is proposed that eliminates most bias by improving mains inlet temperature and by specifying realistic hot water use. This paper outlines the current and the proposed draws and estimates typical ratings changes from draw specification changes for typical systems in four cities.

Burch, J.

2012-06-01T23:59:59.000Z

3

Hot Water Draw Patterns in Single-Family Houses: Findings from Field  

NLE Websites -- All DOE Office Websites (Extended Search)

Hot Water Draw Patterns in Single-Family Houses: Findings from Field Hot Water Draw Patterns in Single-Family Houses: Findings from Field Studies Title Hot Water Draw Patterns in Single-Family Houses: Findings from Field Studies Publication Type Report LBNL Report Number LBNL-4830E Year of Publication 2011 Authors Lutz, James D., Renaldi, Alexander B. Lekov, Yining Qin, and Moya Melody Document Number LBNL-4830E Pagination 26 Date Published 05/2011 Publisher Lawrence Berkeley National Laboratory City Berkeley Abstract This report describes data regarding hot water draw patterns that Lawrence Berkeley National Laboratory obtained from 10 studies. The report describes our purposes in collecting the data; the ways in which we managed, cleaned, and analyzed the data; and the results of our data analysis. We found that daily hot water use is highly variable both among residences and within the same residence. We also found that the distributions of daily hot water use are not symmetrical normal distributions. Thus we used median, not average, values to characterize typical daily hot water use. This report presents summary information that illustrates the results of our data collection and some initial analysis.

4

Solar heating and hot water system installed at the Senior Citizen Center, Huntsville, Alabama. [Includes engineering drawings  

DOE Green Energy (OSTI)

Information is provided on the solar energy system installed at the Huntsville Senior Citizen Center. The solar space heating and hot water facility and the project involved in its construction are described in considerable detail and detailed drawings of the complete system and discussions of the planning, the hardware, recommendations, and other pertinent information are included. The facility was designed to provide 85 percent of the hot water and 85 percent of the space heating requirements. Two important factors concerning this project for commercial demonstration are the successful use of silicon oil as a heat transfer fluid and the architecturally aesthetic impact of a large solar energy system as a visual centerpoint. There is no overheat or freeze protection due to the characteristics of the silicon oil and the design of the system. Construction proceeded on schedule with no cost overruns. It is designed to be relatively free of scheduled maintenance, and has experienced practically no problems.

Not Available

1980-02-01T23:59:59.000Z

5

Hot Water Draw Patterns in Single-Family Houses: Findings from Field Studies  

E-Print Network (OSTI)

water also is used by dishwashers and clothes washers. Hotand water efficient dishwashers and clothes washers. Thepeople clotheswasher dishwasher showers city state bathubs

Lutz, Jim

2012-01-01T23:59:59.000Z

6

Texas Hot Water Report  

NLE Websites -- All DOE Office Websites (Extended Search)

coil hot water storage tank, a backup instantaneous electric water heater, a hydronic fan coil unit for space heating, and an efficient plumbing manifold for domestic hot water...

7

Madrid Hot Water Report  

NLE Websites -- All DOE Office Websites (Extended Search)

Comprehensive Assessment of Hot Water System Page 1 of 2 HOT WATER SYSTEM In general, the plumbing system in MAGIC BOX is designed to concentrate all devices, be they storage,...

8

Solar hot water heater  

SciTech Connect

A solar hot water heater includes an insulated box having one or more hot water storage tanks contained inside and further having a lid which may be opened to permit solar radiation to heat a supply of water contained within the one or more hot water storage tanks. A heat-actuated control unit is mounted on an external portion of the box, such control unit having a single pole double throw thermostat which selectively activates an electric winch gear motor to either open or close the box lid. The control unit operates to open the lid to a predetermined position when exposed to the sun's rays, and further operates to immediately close the lid in response to any sudden drop in temperature, such as might occur during a rainstorm, clouds moving in front of the sun, or the like.

Melvin, H.A.

1982-12-28T23:59:59.000Z

9

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

E-Print Network (OSTI)

hot water draw and energy usage for household samples,Support Document [10]. Energy usage for tankless watersuch a large population, energy usage would be reduced and

Lu, Alison

2011-01-01T23:59:59.000Z

10

Green Systems Solar Hot Water  

E-Print Network (OSTI)

Green Systems Solar Hot Water Heating the Building Co-generation: Heat Recovery System: Solar Thermal Panels (Trex enclosure) Hot Water Storage Tank (TS-5; basement) Hot Water Heaters (HW-1,2; basement) Pre-heats water so water heaters don't need to use as much energy Gas-powered, high efficiency

Schladow, S. Geoffrey

11

Hot water supply system  

SciTech Connect

A hot water supply system is described which consists of: a boiler having an exhaust; solar panels; and a frame supporting the solar panels and including a compartment beneath the solar panels, the boiler exhaust termining in the compartment beneath the solar panels, the boiler being within the compartment.

Piper, J.R.

1986-06-10T23:59:59.000Z

12

Cornell University Hot Water Report  

NLE Websites -- All DOE Office Websites (Extended Search)

Hot Water System Hot Water System The production and delivery of hot water in the CUSD home is technologically advanced, economical, and simple. Hot water is produced primarily by the evacuated solar thermal tube collectors on the roof of the house. The solar thermal tube array was sized to take care of the majority of our heating and hot water needs throughout the course of the year in the Washington, DC climate. The solar thermal tube array also provides heating to the radiant floor. The hot water and radiant floor systems are tied independently to the solar thermal tube array, preventing the radiant floor from robbing the water heater of much needed thermal energy. In case the solar thermal tubes are not able to provide hot water to our system, the hot water tank contains an electric heating

13

Virginia Tech Hot Water Report  

NLE Websites -- All DOE Office Websites (Extended Search)

The team chose to use a water-to-water heat pump (WWHP) connected to an earth coupled heat exchanger to provide water heating. This system provides not only domestic hot water...

14

Estimating Energy and Water Losses in Residential Hot Water Distribution Systems  

E-Print Network (OSTI)

For dishwashers, not only is energy wasted as the hot waterhas the energy used to heat this water been wasted, but thewasted heat as water cools down in the distribution system after a draw; and the energy

Lutz, James

2005-01-01T23:59:59.000Z

15

NREL: Learning - Solar Hot Water  

NLE Websites -- All DOE Office Websites (Extended Search)

Hot Water Hot Water Photo of solar collectors on a roof for a solar hot water system. For solar hot water systems, flat-plate solar collectors are typically installed facing south on a rooftop. The shallow water of a lake is usually warmer than the deep water. That's because the sunlight can heat the lake bottom in the shallow areas, which in turn, heats the water. It's nature's way of solar water heating. The sun can be used in basically the same way to heat water used in buildings and swimming pools. Most solar water heating systems for buildings have two main parts: a solar collector and a storage tank. The most common collector is called a flat-plate collector. Mounted on the roof, it consists of a thin, flat, rectangular box with a transparent cover that faces the sun. Small tubes

16

Residential hot water distribution systems: Roundtablesession  

Science Conference Proceedings (OSTI)

Residential building practice currently ignores the lossesof energy and water caused by the poor design of hot water systems. Theselosses include: combustion and standby losses from water heaters, thewaste of water (and energy) while waiting for hot water to get to thepoint of use; the wasted heat as water cools down in the distributionsystem after a draw; heat losses from recirculation systems and thediscarded warmth of waste water as it runs down the drain. Severaltechnologies are available that save energy (and water) by reducing theselosses or by passively recovering heat from wastewater streams and othersources. Energy savings from some individual technologies are reported tobe as much as 30 percent. Savings calculations of prototype systemsincluding bundles of technologies have been reported above 50 percent.This roundtable session will describe the current practices, summarizethe results of past and ongoing studies, discuss ways to think about hotwater system efficiency, and point to areas of future study. We will alsorecommend further steps to reduce unnecessary losses from hot waterdistribution systems.

Lutz, James D.; Klein, Gary; Springer, David; Howard, Bion D.

2002-08-01T23:59:59.000Z

17

Design and installation package for solar hot water system  

DOE Green Energy (OSTI)

This report contains the design and installation procedure for the Solar Engineering and Manufacturing Company's solar hot water system. Included are the system performance specifications, system design drawings, hazard analysis and other information necessary to evaluate the design and instal the system.

Not Available

1978-12-01T23:59:59.000Z

18

Feasibility study and roadmap to improve residential hot water distribution systems  

E-Print Network (OSTI)

dishwashers, not only is the energy wasted by the hot waterwasted heat as water cools down in the distribution system after a draw; and the energywasted heat as water cools down in the distribution system after a draw; and the energy

Lutz, James D.

2004-01-01T23:59:59.000Z

19

Commonwealth Solar Hot Water Commercial Program | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial Program Commonwealth Solar Hot Water Commercial Program Eligibility Agricultural Commercial Fed. Government Industrial Local Government Multi-Family Residential...

20

dist_hot_water.pdf  

U.S. Energy Information Administration (EIA) Indexed Site

District Hot Water Usage Form District Hot Water Usage Form 1999 Commercial Buildings Energy Consumption Survey (CBECS) 1. Timely submission of this report is mandatory under Public Law 93-275, as amended. 2. This completed questionnaire is due by 3. Data reported on this questionnaire are for the entire building identified in the label to the right. 4. Data may be submitted directly on this questionnaire or in any other format, such as a computer-generated listing, which provides the same i nformation and is conve nient for y our company. a. You may submit a single report for the entire building, or if it i s easier, a separate report for each of several accounts in the building. These will then be aggregated by the survey contractor. b. If you are concerned about your individual account information, you may c

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Estimating Energy and Water Losses in Residential Hot WaterDistribution Systems  

DOE Green Energy (OSTI)

Residential single family building practice currently ignores the losses of energy and water caused by the poor design of hot water systems. These losses include; the waste of water while waiting for hot water to get to the point of use; the wasted heat as water cools down in the distribution system after a draw; and the energy needed to reheat water that was already heated once before. Average losses of water are estimated to be 6.35 gallons (24.0 L) per day. (This is water that is rundown the drain without being used while waiting for hot water.) The amount of wasted hot water has been calculated to be 10.9 gallons (41.3L) per day. (This is water that was heated, but either is not used or issued after it has cooled off.) A check on the reasonableness of this estimate is made by showing that total residential hot water use averages about 52.6 gallons (199 L) per day. This indicates about 20 percent of average daily hot water is wasted.

Lutz, James

2005-02-26T23:59:59.000Z

22

Prototype solar heating and hot water systems  

DOE Green Energy (OSTI)

This document is a collection of two quarterly status reports from Colt, Inc., covering the period from October 1, 1977 through June 30, 1978. Colt is developing two prototype solar heating and hot water systems consisting of the following subsystems: collector, storage, control, transport, hot water, and auxiliary energy. The two systems are being installed at Yosemite, California and Pueblo, Colorado.

Not Available

1978-04-01T23:59:59.000Z

23

Domestic Hot Water Event Schedule Generator - Energy ...  

Residential hot water use in the United States accounts for 14-25% of all the energy consumed in a home. With the rise of more advanced water heating ...

24

Solar heating and hot water system installed at Listerhill, Alabama  

DOE Green Energy (OSTI)

The solar system was installed into a new buildng and was designed to provide 79% of the estimated annual space heating load and 59% of the estimated annual potable hot water requirement. The collectors are flat plate, liquid manufactured by Reynolds Metals Company and cover a total area of 2344 square feet. The storage medium is water inhibited with NALCO 2755 and the container is an underground, unpressurized steel tank with a capacity of 5000 gallons. This final report describes in considerable detail the solar heating facility and contains detailed drawings of the completed system.

Not Available

1978-12-01T23:59:59.000Z

25

DOE Solar Decathlon: 2005 Contests and Scoring - Hot Water  

NLE Websites -- All DOE Office Websites (Extended Search)

teams will install systems that can do even more. The Hot Water contest demonstrates that solar hot water heating systems can supply all the hot water we use daily - to bathe and...

26

Commercial Solar Hot Water Financing Program | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

the commercial solar hot water industry in Massachusetts. Commercial and non-profit building owners can use the financing program to install solar hot water systems that heat...

27

Direct Use for Building Heat and Hot Water Presentation Slides...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Direct Use for Building Heat and Hot Water Presentation Slides and Text Version Direct Use for Building Heat and Hot Water Presentation Slides and Text Version Download...

28

FEMP Solar Hot Water Calculator | Open Energy Information  

Open Energy Info (EERE)

Solar Hot Water Calculator Jump to: navigation, search Name FEMP Solar Hot Water Calculator Abstract Online tool to help Federal agencies meet Energy Independence and Security Act...

29

System design package for SIMS prototype system 3, solar heating and domestic hot water  

DOE Green Energy (OSTI)

This report is a collation of documents and drawings that describe a prototype solar heating and hot water system using liquid flat plat collectors and a gas or electric furnace energy subsystem. The system was designed for installation into a single-family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system are packaged for evaluation of the system with information sufficient to assemble a similar system. The SIMS Prototype Heating and Hot Water System, Model Number 3 has been installed in a residence at Glendo State Park, Glendo, Wyoming.

Not Available

1978-11-01T23:59:59.000Z

30

Solar heating, cooling and domestic hot water system installed at Columbia Gas System Service Corp. , Columbus, Ohio. Final report  

DOE Green Energy (OSTI)

The Solar Energy System located at the Columbia Gas Corporation, Columbus, Ohio, has 2978 ft/sup 2/ of Honeywell single axis tracking, concentrating collectors and provides solar energy for space heating, space cooling and domestic hot water. A 1,200,000 Btu/h Bryan water-tube gas boiler provides hot water for space heating. Space cooling is provided by a 100 ton Arkla hot water fired absorption chiller. Domestic hot water heating is provided by a 50 gallon natural gas domestic storage water heater. Extracts are included from the site files, specification references, drawings, installation, operation and maintenance instructions.

Not Available

1980-11-01T23:59:59.000Z

31

Hot tips on water heating  

SciTech Connect

Water-heater manufacturers responded to the call for energy conservation with innovations and efficiency standards for the home, business, and plant. Conventional tank-type water heaters offer better design and insulation, but the heat-pump water heater offers the highest efficiency. Available in add-on units and integral units, they now represent up to 40% of manufacturers' sales. Other advances are the desuperheater devices which recapture air-conditioner waste heat, solar-water-heating systems, instantaneous water heaters, and industrial heat-recovery systems for process water. 1 figure. (DCK)

Forker, J.

1982-03-01T23:59:59.000Z

32

Feasibility study and roadmap to improve residential hot water distribution systems  

DOE Green Energy (OSTI)

Residential building practice currently ignores the losses of energy and water caused by the poor design of hot water systems. These losses include: the waste of water while waiting for hot water to get to the point of use; the wasted heat as water cools down in the distribution system after a draw; and the energy to reheat water that was already heated once before. A feasibility study and an action plan for a proposed research project involving residential hot water distribution systems is being developed. The feasibility study will use past work to estimate of hot water and energy loses caused by current hot water distribution systems in residences. Proposed research project, or roadmap, will develop recommendations for improvements to residential hot water distribution systems. The roadmap addresses the technical obstacles and gaps in our knowledge that prevent water and energy reductions and market adoption of water- and energy-efficient technologies. The initial results of the feasibility study are presented here along with a discussion of a roadmap to improve the efficiency of residential hot water distribution systems.

Lutz, James D.

2004-03-31T23:59:59.000Z

33

Water Heaters and Hot Water Distribution Systems  

E-Print Network (OSTI)

gas water heaters; and pressure loss calculations for residentialgas water heaters; and pressure loss calculations for residential

Lutz, Jim

2012-01-01T23:59:59.000Z

34

University of Colorado Hot Water Report  

NLE Websites -- All DOE Office Websites (Extended Search)

Hot water system Brief Contest Report Hot water system Brief Contest Report Recognizing that the sun is an abundant source of clean energy that reaches the earth at an intensity of up to 1000 Watts/m 2 , the University of Colorado will be showcasing top-of-the-line technology in which solar radiation is converted into heat for the purposes of heating the home and providing domestic hot water. Solar Thermal System - Basics Colorado's 2005 Solar Decathlon team has chosen to harness the sun's thermal energy with 4 arrays of 20 Mazdon evacuated tube collectors manufactured by Thermomax, as shown in Figure 1 below. These collectors have incredibly high efficiencies - about 60% over the course of an entire day. In addition, the evacuated tube collectors resist internal condensation and corrosion more effectively than their counterparts

35

Water Heaters and Hot Water Distribution Systems  

E-Print Network (OSTI)

The effect on water and gas usage from cross-flow betweencontrols have on water and gas usage over a large number ofsystems, and their water and gas usage. Hourly schedules for

Lutz, Jim

2012-01-01T23:59:59.000Z

36

Solar heating and hot water system installed at Shoney's Restaurant, North Little Rock, Arkansas. Final report  

Science Conference Proceedings (OSTI)

The solar heating system is designed to supply a major portion of the space and water heating requirements for a newly built Shoney's Big Boy Restaurant which was installed with completion occurring in December 1979. The restaurant has a floor space of approximately 4,650 square feet and requires approximately 1500 gallons of hot water daily. The solar energy system consists of 1,428 square feet of Chamberlain flat plate liquid collector subsystem, and a 1500 gallon storage subsystem circulating hot water producing 321 x 10/sup 6/ Btu/yr (specified) building heating and hot water heating. Designer - Energy Solutions, Incorporated. Contractor - Stephens Brothers, Incorporated. This report includes extracts from site files, specification references for solar modifications to existing building heating and hot water systems, drawings installation, operation and maintenance instructions.

Not Available

1980-08-01T23:59:59.000Z

37

STATE OF CALIFORNIA DOMESTIC HOT WATER (DHW)  

E-Print Network (OSTI)

: Heater Type CEC Certified Mfr Name & Model Number Distribution Type (Std, Point-of- Use, etc; and Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements six or fewer dwelling units which have (1) less than 25' of distribution piping outdoors; (2) zero

38

Validation of a Hot Water Distribution Model Using Laboratory and Field Data  

SciTech Connect

Characterizing the performance of hot water distribution systems is a critical step in developing best practice guidelines for the design and installation of high performance hot water systems. Developing and validating simulation models is critical to this effort, as well as collecting accurate input data to drive the models. In this project, the ARBI team validated the newly developed TRNSYS Type 604 pipe model against both detailed laboratory and field distribution system performance data. Validation efforts indicate that the model performs very well in handling different pipe materials, insulation cases, and varying hot water load conditions. Limitations of the model include the complexity of setting up the input file and long simulation run times. In addition to completing validation activities, this project looked at recent field hot water studies to better understand use patterns and potential behavioral changes as homeowners convert from conventional storage water heaters to gas tankless units. Based on these datasets, we conclude that the current Energy Factor test procedure overestimates typical use and underestimates the number of hot water draws. This has implications for both equipment and distribution system performance. Gas tankless water heaters were found to impact how people use hot water, but the data does not necessarily suggest an increase in usage. Further study in hot water usage and patterns is needed to better define these characteristics in different climates and home vintages.

Backman, C.; Hoeschele, M.

2013-07-01T23:59:59.000Z

39

Water Heaters and Hot Water Distribution Systems  

E-Print Network (OSTI)

Water Distribution System Recommendations for the 2008 Title- 24 Residential Building Energy Efficiency Standards .. 4 Multi-FamilyWater Distribution System Recommendations for the 2008 Title- 24 Residential Building Energy Efficiency Standards 11 Multi-FamilyWater Distribution System Recommendations for the 2008 Title- 24 Residential Building Energy Efficiency Standards 48 Multi-Family

Lutz, Jim

2012-01-01T23:59:59.000Z

40

Alternatives for reducing hot-water bills  

DOE Green Energy (OSTI)

A two stage approach to reducing residential water heating bills is described. In Stage I, simple conservation measures were included to reduce the daily hot water energy consumption and the energy losses from the water tank. Once these savings are achieved, Stage II considers more costly options for further reducing the water heating bill. Four alternatives are considered in Stage II: gas water heaters; solar water heaters (two types); heat pump water heaters; and heat recovery from a heat pump or air conditioner. To account for variations within the MASEC region, information on water heating in Rapid City, Minneapolis, Chicago, Detroit, and Kansas City is presented in detail. Information on geography, major population centers, fuel prices, climate, and state solar incentives is covered. (MCW)

Bennington, G.E.; Spewak, P.C.

1981-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

home power 114 / august & september 2006 in Solar Hot Water  

E-Print Network (OSTI)

water entering the heat exchanger, and the hot water being produced. "I don't know..." I replied. The graphs show that the ultimate temperature of the solar-produced hot water is indeed higher therms) Percentage of hot water produced annually: Approximately 70 percent Equipment Collectors: Two

Knowles, David William

42

Solar Hot Water Resources and Technologies | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Hot Water Resources and Technologies Solar Hot Water Resources and Technologies Solar Hot Water Resources and Technologies October 7, 2013 - 11:49am Addthis Photo of a standalone solar hot water system standing in front of a clothesline with a backdrop of evergreen trees. This solar hot water system tracks sunlight using a standalone, single-axis mount to optimize hot water production for residential applications. This page provides a brief overview of solar hot water (SHW) technologies supplemented by specific information to apply SHW within the Federal sector. Overview Although a large variety of solar hot water systems exist, the basic technology is simple. A collector absorbs and transfers heat from the sun to water, which is stored in a tank until needed. Active solar heating systems use circulating pumps and controls. These are more expensive but

43

Arnold Schwarzenegger WATER HEATERS AND HOT WATER  

E-Print Network (OSTI)

controls. This response applies to markets that have a demand for central water heating systems Distribution Systems Subtask 2.1 Multifamily Water Heating Construction Practices, Pricing and Availability systems in multifamily buildings. This market characterization study is helping HMG develop

44

Federal Energy Management Program: Solar Hot Water Resources and  

NLE Websites -- All DOE Office Websites (Extended Search)

Solar Hot Water Solar Hot Water Resources and Technologies to someone by E-mail Share Federal Energy Management Program: Solar Hot Water Resources and Technologies on Facebook Tweet about Federal Energy Management Program: Solar Hot Water Resources and Technologies on Twitter Bookmark Federal Energy Management Program: Solar Hot Water Resources and Technologies on Google Bookmark Federal Energy Management Program: Solar Hot Water Resources and Technologies on Delicious Rank Federal Energy Management Program: Solar Hot Water Resources and Technologies on Digg Find More places to share Federal Energy Management Program: Solar Hot Water Resources and Technologies on AddThis.com... Energy-Efficient Products Technology Deployment Renewable Energy Federal Requirements Renewable Resources & Technologies

45

Solar-hot-water-heater lease program  

SciTech Connect

Ten domestic hot-water solar systems were installed, leased to homeowners, and monitored for two years. All of the systems were installed as back-ups to electric water heaters. The systems consist of two to four collectors, a solar storage tank (as well as the existing non-solar heater), and a heat exchanger package. Eight are three-collector systems, one is a four-collector and one a two-collector system. The systems were sized according to family size and predicted hot water demand. The monitoring consists of a separate KW reading on the non-solar water heater, a reading of gallons of how water consumed, and hot and cold outlet temperatures. The purpose for the study was fourfold: (1) to determine the level of acceptance by the general public of solar water heaters if available on a lease rather than a purchase basis; (2) to measure the actual energy savings to the average homeowner in central Illinois with a solar water heater; (3) to measure the potential reduction of Cilco's energy production requirements, should there be widespread utilization of these systems; and (4) to determine the feasibility of an entrepreneur making these systems available on a rental basis and remaining a going concern. The results of this study indicate that the leasing of solar equipment to homeowners has a more widespread acceptance than the direct purchase of such systems. Homeowners, however, do not want to spend as much money on monthly lease payments as the supplier of the equipment would deem necessary. This seriously questions the feasibility of an entrepreneurial leasing program.

Rutherford, S.

1983-04-01T23:59:59.000Z

46

Efficiency of Steam and Hot Water Heat Distribution Systems  

E-Print Network (OSTI)

Efficiency of Steam and Hot Water Heat Distribution Systems Gary Phetteplace September 1995- tion medium (steam or hot water) and temperature for heat distribution systems. The report discusses the efficiency of both steam and hot water heat distribution systems in more detail. The results of several field

47

Prototype solar heating and cooling systems, including potable hot water. Quarterly report  

DOE Green Energy (OSTI)

The progress made in the development, delivery and support of two prototype solar heating and cooling systems including potable hot water is reported. The system consists of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition. Included is a comparison of the proposed Solaron-Heat Pump and Solaron-Desiccant Heating and Cooling Systems, Installation Drawings, data on the Akron House at Akron, Ohio, and other program activities from July 1, 1977 through November 9, 1977.

Not Available

1977-12-01T23:59:59.000Z

48

System design package for SIMS Prototype System 2, solar hot water  

DOE Green Energy (OSTI)

This report is a collection of documents and drawings that describe a solar hot water system. The necessary information to evaluate the design and with information sufficient to assemble a similar system is presented. The International Business Machines Corporation developed prototype system 2 solar hot water for use in a single family dwelling. The system has been installed in Building Number 20, which is a single family residence on the grounds of the Veterans Administration Hospital at Togus, Maine. It consists of the following subsystems: collector, storage, energy transport, and control. It is a design with wide-spread application potential with only slight adjustments necessary in system size.

Not Available

1977-12-01T23:59:59.000Z

49

The Chilled Water and Hot Water Building Differential Pressure Setpoint Calculation - Chilled Water and Hot Water Pump Speed Control  

E-Print Network (OSTI)

More and more variable frequency devices (VFD) are being installed on the chilled water and hot water pumps on the TAMU campus. Those pump speeds are varied to maintain chilled water or hot water building deferential pressure (DP) or return temperature or flow rate at their setpoints. The chilled water and hot water DP setpoint or return temperature setpoint or flow rate setpoint was a constant value or reset based on outside air temperature. In some buildings, the chilled water and hot water DP setpoints were reset based on flow rate, but in many instances those setpoint schedules were either too low to maintain enough building DP requirement or too high and consumed excess energy. The building DP reset schedule based on flow rate is studied and compared with the other pump speed control methods. Because the building DP setpoint based on flow rate method is achieved by tracking the load change, it saves energy than the other methods. In this paper its calculation procedure is generated and the example of the building DP calculation is given.

Turner, W. D.; Bruner, H., Jr.; Claridge, D.; Liu, C.; Deng, S.

2002-01-01T23:59:59.000Z

50

Hot water can freeze faster than cold?!?  

E-Print Network (OSTI)

We review the Mpemba effect, where intially hot water freezes faster than initially cold water. While the effect appears impossible at first sight, it has been seen in numerous experiments, was reported on by Aristotle, Francis Bacon, and Descartes, and has been well-known as folklore around the world. It has a rich and fascinating history, which culminates in the dramatic story of the secondary school student, Erasto Mpemba, who reintroduced the effect to the twentieth century scientific community. The phenomenon, while simple to describe, is deceptively complex, and illustrates numerous important issues about the scientific method: the role of skepticism in scientific inquiry, the influence of theory on experiment and observation, the need for precision in the statement of a scientific hypothesis, and the nature of falsifiability. We survey proposed theoretical mechanisms for the Mpemba effect, and the results of modern experiments on the phenomenon. Studies of the observation that hot water pipes are more likely to burst than cold water pipes are also described.

Monwhea Jeng

2005-12-29T23:59:59.000Z

51

Savings Project: Insulate Hot Water Pipes for Energy Savings | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Insulate Hot Water Pipes for Energy Savings Insulate Hot Water Pipes for Energy Savings Savings Project: Insulate Hot Water Pipes for Energy Savings Addthis Project Level Medium Energy Savings $8-$12 annually Time to Complete 3 hours for a small house Overall Cost $10-$15 Insulating water pipes can save you water, energy, and money. | Photo courtesy of iStockphoto.com/nsj-images Insulating water pipes can save you water, energy, and money. | Photo courtesy of iStockphoto.com/nsj-images Insulating your hot water pipes reduces heat loss and can raise water temperature 2°F-4°F hotter than uninsulated pipes can deliver, allowing for a lower water temperature setting. You also won't have to wait as long for hot water when you turn on a faucet or showerhead, which helps conserve water. Paying for someone to insulate your pipes-as a project on its own-may

52

Geothermal hot water pump. Final report  

DOE Green Energy (OSTI)

The design, testing and performance capabilities of a Geothermal Hot Water Pumping System being developed are described. The pumping system is intended to operate submerged in geothermal brine wells for extended periods of time. Such a system confines the hot brine in a closed-loop under pressure to prevent the liquid from flashing into steam, in addition to providing a means for reinjecting cooled water and the contaminants into a return well. The system consists of a single-stage centrifugal pump driven by an oil-cooled, high-speed electric motor with integral heat exchanger. For testing purposes a diesel engine driven 400 Hz generator is used for supplying power to the motor. In some areas where commercial power may not be available, the diesel-generator unit or either a rotating or solid state frequency converter may be used to produce the high frequency power required by the motor. Fabrication of a prototype system and testing of the electric motor at frequencies up to 250 Hz was completed. While testing at 275 Hz it was necessary to terminate the testing when the motor stator was damaged as a result of a mechanical failure involving the motor-dynamometer drive adaptor. Test results, although limited, confirm the design and indicate that the performance is as good, or better than predicted. These results also indicate that the motor is capable of achieving rated performance.

Not Available

1977-09-30T23:59:59.000Z

53

Geothermal hot water pump. Final report  

SciTech Connect

The design, testing and performance capabilities of a Geothermal Hot Water Pumping System are described. The pumping system is intended to operate submerged in geothermal brine wells for extended periods of time. Such a system confines the hot brine in a closed-loop under pressure to prevent the liquid from flashing into steam, in addition to providing a means for reinjecting cooled water and the contaminates into a return well. The system consists of a single-stage centrifugal pump driven by an oil-cooled, high-speed electric motor with integral heat exchanger. For testing purposes a diesel engine driven 400 Hz generator is used for supplying power to the motor. In some areas where commercial power may not be available, the diesel-generator unit or either a rotating or solid state frequency converter may be used to produce the high frequency power required by the motor. Fabrication of a prototype system and testing of the electric motor at frequencies up to 250 Hz was completed. While testing at 275 Hz it was necessary to terminate the testing when the motor stator was damaged as a result of a mechanical failure involving the motor-dynamometer drive adaptor.

1977-09-30T23:59:59.000Z

54

Webinar: ENERGY STAR Hot Water Systems for High Performance Homes  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Star Hot Water Systems for High Performance Homes Star Hot Water Systems for High Performance Homes 1 | Building America Program www.buildingamerica.gov Buildings Technologies Program Date: September 30, 2011 ENERGY STAR ® Hot Water Systems for High Performance Homes Welcome to the Webinar! We will start at 11:00 AM Eastern. There is no call in number. The audio will be sent through your computer speakers. All questions will be submitted via typing. Video of presenters Energy Star Hot Water Systems for High Performance Homes 2 | Building America Program www.buildingamerica.gov Energy Star Hot Water Systems for High Performance Homes 3 | Building America Program www.buildingamerica.gov Building America Program: Introduction Building Technologies Program Energy Star Hot Water Systems for High Performance Homes

55

Hot New Advances in Water Heating Technology | ornl.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

ENERGY.GOV - Hot New Advances in Water Heating Technology April 18, 2013 Here at the Energy Department, we are working with our National Laboratories, private companies and...

56

Solar heating and hot water system installed at St. Louis, Missouri. Final report  

DOE Green Energy (OSTI)

Information is provided on the solar heating and hot water system installed at the William Tao and Associates, Inc., office building in St. Louis, Missouri. The information consists of description, photos, maintenance and construction problems, final drawing, system requirements and manufacturer's component data. The solar system was designed to provide 50% of the hot water requirements and 45% of the space heating needs for a 900 square foot office space and drafting room. The solar facility has 252 square foot of glass tube concentrator collectors and a 1000 gallon steel storage tank buried below a concrete slab floor. Freeze protection is provided by a propylene glycol/water mixture in the collector loop. The collectors are roof mounted on a variable tilt array which is adjusted seasonally and is connected to the solar thermal storage tank by a tube-in-shell heat exchanger. Incoming city water is preheated through the solar energy thermal storage tank.

Not Available

1980-04-01T23:59:59.000Z

57

HEATING OF OIL WELL BY HOT WATER CIRCULATION  

E-Print Network (OSTI)

HEATING OF OIL WELL BY HOT WATER CIRCULATION Mladen Jurak Department of Mathematics University.prnic@ina.hr Abstract When highly viscous oil is produced at low temperatures, large pressure drops will significantly decrease production rate. One of possible solu- tions to this problem is heating of oil well by hot water

Rogina, Mladen

58

Analysis Model for Domestic Hot Water Distribution Systems: Preprint  

DOE Green Energy (OSTI)

A thermal model was developed to estimate the energy losses from prototypical domestic hot water (DHW) distribution systems for homes. The developed model, using the TRNSYS simulation software, allows researchers and designers to better evaluate the performance of hot water distribution systems in homes. Modeling results were compared with past experimental study results and showed good agreement.

Maguire, J.; Krarti, M.; Fang, X.

2011-11-01T23:59:59.000Z

59

Modeling patterns of hot water use in households  

E-Print Network (OSTI)

various usage characteristics associated with electric, gas-Usage: A Review of Published Metered Studies. Prepared for Gasgas, may be an incentive for people with electric water heaters to reduce their hot water usage.

Lutz, James D.; Liu, Xiaomin; McMahon, James E.; Dunham, Camilla; Shown, Leslie J.; McCure, Quandra T.

1996-01-01T23:59:59.000Z

60

Reduce Hot Water Use for Energy Savings | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Reduce Hot Water Use for Energy Savings Reduce Hot Water Use for Energy Savings Reduce Hot Water Use for Energy Savings June 15, 2012 - 5:51pm Addthis Low-flow fixtures and showerheads can achieve water savings of 25%–60%. | Photo courtesy of ©iStockphoto/DaveBolton. Low-flow fixtures and showerheads can achieve water savings of 25%-60%. | Photo courtesy of ©iStockphoto/DaveBolton. What does this mean for me? Fix leaks, install low-flow fixtures, and purchase an energy-efficient dishwasher and clothes washer to use less hot water and save money. You can lower your water heating costs by using and wasting less hot water in your home. To conserve hot water, you can fix leaks, install low-flow fixtures, and purchase an energy-efficient dishwasher and clothes washer. Fix Leaks You can significantly reduce hot water use by simply repairing leaks in

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Solar Hot Water Creates Savings for Homeless Shelters | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Hot Water Creates Savings for Homeless Shelters Solar Hot Water Creates Savings for Homeless Shelters Solar Hot Water Creates Savings for Homeless Shelters July 15, 2010 - 12:10pm Addthis Kevin Craft What are the key facts? Recovery Act funds are being used to install solar hot water systems at 5 Phoenix shelters. The systems will save Phoenox 33,452 kWh of energy -- about $4,000 -- annually. The systems will reduce about 40,000 pounds of carbon emissions annually. "This project will save us a huge amount of money," says Paul Williams, House of Refuge Sunnyslope's Executive Director. Williams is referring to a recent partnership between the state of Arizona and House of Refuge Sunnyslope to install solar hot water systems at five Phoenix-area housing sites for homeless men, which will make an immediate difference at the

62

Tool for Generating Realistic Residential Hot Water Event Schedules: Preprint  

SciTech Connect

The installed energy savings for advanced residential hot water systems can depend greatly on detailed occupant use patterns. Quantifying these patterns is essential for analyzing measures such as tankless water heaters, solar hot water systems with demand-side heat exchangers, distribution system improvements, and recirculation loops. This paper describes the development of an advanced spreadsheet tool that can generate a series of year-long hot water event schedules consistent with realistic probability distributions of start time, duration and flow rate variability, clustering, fixture assignment, vacation periods, and seasonality. This paper also presents the application of the hot water event schedules in the context of an integral-collector-storage solar water heating system in a moderate climate.

Hendron, B.; Burch, J.; Barker, G.

2010-08-01T23:59:59.000Z

63

NREL: Learning - Student Resources on Solar Hot Water  

NLE Websites -- All DOE Office Websites (Extended Search)

Solar Hot Water Solar Hot Water Photo of a school building next to a pond. Roy Lee Walker Elementary School in Texas incorporates many renewable energy design features, including solar hot water heating. The following resources will help you learn more about solar water heating systems. If you are unfamiliar with this technology, see the introduction to solar hot water. Grades 7-12 NREL Educational Resources Educational resources available to students from the National Renewable Energy Laboratory. High School and College Level U.S. Department of Energy's Energy Savers: Solar Water Heaters Features comprehensive basic information and resources. U.S. Department of Energy's Energy Savers: Solar Swimming Pool Heaters Features comprehensive basic information and resources. U.S. Department of Energy Solar Decathlon

64

HOt Water SavEr (HOWSE) Project. Final report  

SciTech Connect

The dishwasher effluent is pumped into the flue of the exchange tank by the normal dishwasher pump (or auxiliary pump). The effluent is stored in this tank until next operation of the dishwasher. Thus, thermal equilibrium can be reached between the tank and the effluent, promoting high efficiency. The output from the exchange tank feeds the household normal hot water tank, reducing its requirement for fuel as the input water temperature is higher. Counterflow exchangers may be used for other hot water users where the flow and drain is continuous. In this case the discharged hot (or warm) water flows counter to the flow of cold water into the hot water heater. The two flows are closely coupled thermally but not in direct contract so they cannot mix. Counter flow exchangers and storage type exchangers may be used in the same installation.

Olson, W.R.

1981-12-31T23:59:59.000Z

65

System design package for SIMS Prototype System 4, solar heating and domestic hot water  

DOE Green Energy (OSTI)

This report is a collation of documents and drawings that describe a prototype solar heating and hot water system using air type solar energy collection techniques. The system consists of a modular designed prepackaged solar unit containing solar collctors, a rock storage container, blowers, dampers, ducting, air-to-water heat exchanger, DHW preheat tank, piping and system controls. The system was designed to be installed adjacent to a small single family dwelling. The description, performance specification, subsystem drawings, verification plan/procedure, and hazard analysis of the system are packaged for evaluation of the system with inforation sufficient to assemble a similar system. The prepackage solar unit has been installed at the Mississippi Power and Light Company, Training Facilities, Clinton, Mississippi.

Not Available

1978-11-01T23:59:59.000Z

66

Solar Hot Water Contractor Licensing | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Hot Water Contractor Licensing Hot Water Contractor Licensing Solar Hot Water Contractor Licensing < Back Eligibility Installer/Contractor Savings Category Heating & Cooling Solar Water Heating Program Info State Arkansas Program Type Solar/Wind Contractor Licensing Arkansas offers several limited, specialty licenses for solar thermal installers under the general plumbing license. There are three specialty classifications available for solar thermal installers: a Restricted Solar Mechanic license, a Supervising Solar Mechanic license, and a Solar Mechanic Trainee classification. Installers with a Restricted Solar Mechanic license can install and maintain systems used to heat domestic hot water, but are not allowed to perform any other plumbing work. Individuals holding a Supervising Solar Mechanic license are able to supervise, install

67

Circulo: Saving Energy with Just-In-Time Hot Water Recirculation  

Science Conference Proceedings (OSTI)

The average home in the US flushes 1000's of gallons of water down the drain each year while standing at the fixture and waiting for hot water. Some households use a pump for hot water recirculation (HWR) to ensure that hot water is always immediately ... Keywords: Energy and Water Conservation, Hot Water Recirculation

Andrew Frye, Michel Goraczko, Jie Liu, Anindya Prodhan, Kamin Whitehouse

2013-11-01T23:59:59.000Z

68

City of San Jose - Solar Hot Water Heaters and Photovoltaic Systems...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Hot Water Heaters and Photovoltaic Systems Permit Requirements City of San Jose - Solar Hot Water Heaters and Photovoltaic Systems Permit Requirements Eligibility Commercial...

69

Domestic Hot Water Consumption in Four Low-Income Apartment Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Domestic Hot Water Consumption in Four Low-Income Apartment Buildings Title Domestic Hot Water Consumption in Four Low-Income Apartment Buildings Publication Type Conference...

70

DOE Solar Decathlon: News Blog » Hot Water  

NLE Websites -- All DOE Office Websites (Extended Search)

Hot Water Hot Water Below you will find Solar Decathlon news from the Hot Water archive, sorted by date. New Contest Data Displays Provide Insight into Competition Scoring Saturday, October 5, 2013 By Solar Decathlon New contest data displays are now available on the U.S. Department of Energy Solar Decathlon website. If you are interested in the real-time performance of each house and want to keep a close eye on the competition, check out the Contests section pages. In the Contests section, the pages for the measured contests (Comfort Zone, Hot Water, Appliances, Home Entertainment, and Energy Balance) explain the contest requirements and provide real-time graphical displays of the accumulated measurements/scores for each team. Roll your cursor over the graphics to see more detailed information about each contest. For example,

71

An Energy Policy Perspective on Solar Hot Water Equipment Mandates  

E-Print Network (OSTI)

An Energy Policy Perspective on Solar Hot Water EquipmentU.S. OIL VULNERABILITY: ENERGY POLICY FOR THE 1980's, DOE/cited as Langston]. ENERGY POLICY tween a new house with

Williams, Stephen F.

1981-01-01T23:59:59.000Z

72

Observations from the field: Solar domestic hot water installation recommendations  

SciTech Connect

The Florida Solar Energy Center (FSEC) was ten years old in 1984. Constant contact has been maintained between the Center and solar businesses selling and installing domestic hot water systems in Florida and throughout the Southern states of the Caribbean. FSEC has thus had the opportunity to visit or discuss thousands of DHW system installations with homeowners and installers. This paper provides an overview of lessons learned and some of the resulting installation recommendations for direct, open-loop domestic hot water systems.

Cromer, C.J.

1985-01-01T23:59:59.000Z

73

Hot New Advances in Water Heating Technology | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Hot New Advances in Water Heating Technology Hot New Advances in Water Heating Technology Hot New Advances in Water Heating Technology April 18, 2013 - 1:15pm Addthis Learn how a cooperative R&D agreement with the Energy Department's Oak Ridge National Laboratory helped contributed to the success of GE's GeoSpring Hybrid Water Heater -- one of the most efficient electric heat pump water heaters on the market today. Rebecca Matulka Rebecca Matulka Digital Communications Specialist, Office of Public Affairs Got Energy Efficiency Questions? Our energy efficiency and renewable energy experts will answer your questions about ways to save money and incorporate renewable energy into your home during our Earth Day Google+ Hangout on April 22 at 3 pm ET. Submit your questions on Twitter, G+ and YouTube using #askEnergy,

74

Hot New Advances in Water Heating Technology | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Hot New Advances in Water Heating Technology Hot New Advances in Water Heating Technology Hot New Advances in Water Heating Technology April 18, 2013 - 1:15pm Addthis Learn how a cooperative R&D agreement with the Energy Department's Oak Ridge National Laboratory helped contributed to the success of GE's GeoSpring Hybrid Water Heater -- one of the most efficient electric heat pump water heaters on the market today. Rebecca Matulka Rebecca Matulka Digital Communications Specialist, Office of Public Affairs Got Energy Efficiency Questions? Our energy efficiency and renewable energy experts will answer your questions about ways to save money and incorporate renewable energy into your home during our Earth Day Google+ Hangout on April 22 at 3 pm ET. Submit your questions on Twitter, G+ and YouTube using #askEnergy,

75

Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet)  

SciTech Connect

Over recent years, heat pump water heaters (HPWHs) have become more readily available and more widely adopted in the marketplace. For a 6-month period, the Building America team Consortium for Advanced Residential Buildings monitored the performance of a GE Geospring HPWH in Windermere, Florida. The study found that the HPWH performed 144% more efficiently than a traditional electric resistance water heater, saving approximately 64% on water heating annually. The monitoring showed that the domestic hot water draw was a primary factor affecting the system's operating efficiency.

Metzger, C.; Puttagunta, S.; Williamson, J.

2013-11-01T23:59:59.000Z

76

Commonwealth Solar Hot Water Residential Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commonwealth Solar Hot Water Residential Program Commonwealth Solar Hot Water Residential Program Commonwealth Solar Hot Water Residential Program < Back Eligibility Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Solar Heating Water Heating Maximum Rebate $3,500 per building or 25% of total installed costs Program Info Funding Source Massachusetts Renewable Energy Trust Fund Start Date 02/07/2011 Expiration Date 12/31/2016 State Massachusetts Program Type State Rebate Program Rebate Amount Base rate: $45 X SRCC rating in thousands btu/panel/day (Category D, Mildly Cloudy Day) Additional $200/system for systems with parts manufactured in Massachusetts Additional $1,500/system for metering installation Adder for natural disaster relief of twice the base rebate.

77

NV Energy (Northern Nevada) - Solar Hot Water Incentive Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NV Energy (Northern Nevada) - Solar Hot Water Incentive Program NV Energy (Northern Nevada) - Solar Hot Water Incentive Program NV Energy (Northern Nevada) - Solar Hot Water Incentive Program < Back Eligibility Commercial Fed. Government Local Government Nonprofit Residential Schools State Government Savings Category Heating & Cooling Solar Water Heating Maximum Rebate Residential electric customers: Lesser of 50% or $2,000 Residential gas customers: Lesser of 30% or $3,000 Small commercial gas customers: Lesser of 30% or $7,500 Nonprofits, schools and other public gas customers: Lesser of 50% or $30,000 Program Info Start Date 2/1/2011 State Nevada Program Type Utility Rebate Program Rebate Amount Residential electric customers: Lesser of 50% or $2,000 Residential gas customers: $14.50 per therm Small commercial gas customers: $14.50 per therm

78

Modeling patterns of hot water use in households  

Science Conference Proceedings (OSTI)

This report presents a detailed model of hot water use patterns in individual household. The model improves upon an existing model by including the effects of four conditions that were previously unaccounted for: the absence of a clothes washer; the absence of a dishwasher; a household consisting of seniors only; and a household that does not pay for its own hot water use. Although these four conditions can significantly affect residential hot water use, and have been noted in other studies, this is the first time that they have been incorporated into a detailed model. This model allows detailed evaluation of the impact of potential efficiency standards for water heaters and other market transformation policies. 21 refs., 3 figs., 10 tabs.

Lutz, J.D.; Liu, Xiaomin; McMahon, J.E. [and others

1996-11-01T23:59:59.000Z

79

Modeling patterns of hot water use in households  

SciTech Connect

This report presents a detailed model of hot water use patterns in individual households. The model improves upon an existing model by including the effects of four conditions that were previously unaccounted for: the absence of a clothes washer; the absence of a dishwasher; a household consisting of seniors only; and a household that does not pay for its own hot water use. Although these four conditions can significantly affect residential hot water use, and have been noted in other studies, this is the first time that they have been incorporated into a detailed model. This model allows detailed evaluation of the impact of potential efficiency standards for water heaters and other market transformation policies.

Lutz, James D.; Liu, Xiaomin; McMahon, James E.; Dunham, Camilla; Shown, Leslie J.; McCure, Quandra T.

1996-01-01T23:59:59.000Z

80

Solar Hot Water Contractor Licensing | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Hot Water Contractor Licensing Solar Hot Water Contractor Licensing Solar Hot Water Contractor Licensing < Back Eligibility Installer/Contractor Savings Category Heating & Cooling Solar Water Heating Program Info State Maine Program Type Solar/Wind Contractor Licensing In order to be eligible for Maine's solar thermal rebate program, systems must be installed by licensed plumbers who have received additional certification for solar thermal systems from the North American Board of Certified Energy Practitioners (NABCEP). The state solar thermal rebate program maintains a list of Efficiency Maine registered vendors/installers. In addition, Efficiency Maine has information for vendors interested in becoming registered and listed on the [http://www.efficiencymaine.com/at-home/registered-vendor-locator web

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Commonwealth Solar Hot Water Commercial Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commonwealth Solar Hot Water Commercial Program Commonwealth Solar Hot Water Commercial Program Commonwealth Solar Hot Water Commercial Program < Back Eligibility Agricultural Commercial Fed. Government Industrial Local Government Multi-Family Residential Nonprofit Schools State Government Tribal Government Savings Category Heating & Cooling Solar Water Heating Maximum Rebate Feasibility study: $5,000; Construction: 25% system costs or $50,000 Program Info Funding Source Massachusetts Renewable Energy Trust Fund Start Date 08/04/2011 State Massachusetts Program Type State Rebate Program Rebate Amount Feasibility study: $5,000; Construction grants: $45*number of collectors*SRCC Rating (Private); $55*number of collectors*SRCC Rating (Public/Non-Profit) Massachusetts Manufactured adder: $200-$500 Metering adder: Up to $1,500

82

A model of the domestic hot water load  

SciTech Connect

The electrical load required to supply domestic hot water is an important load for two reasons: (1) It represents a large portion (30 to 50%) of the domestic load; (2) It is a load which can easily be controlled by the consumer or the supplier, because the use of the hot water need not coincide with the heating of hot water. A model representing the electrical system load due to hot water consumption from storage water heaters is provided. Variable parameters include the average amount of water used, the mean and deviation of distributions of usage times, thermostat settings, inlet water temperature and electrical heating element ratings. These parameters are used to estimate the after diversity electricity demand profile, and were verified for accuracy by comparison with measurements. The model enables this prediction of the effects of load control, examples of which are given in this paper. The model is also useful for evaluation of the response which could be expected from demand-side management options. These include changing the size of heating elements, reduction in water consumption and reduction in thermostat settings.

Lane, I.E. [Energy Efficiency Enterprises, Lynnwood Manor (South Africa); Beute, N. [Cape Technikon, Cape Town (South Africa)

1996-11-01T23:59:59.000Z

83

Solar Hot Water for Your Home  

DOE Green Energy (OSTI)

A brochure describing the cost-saving and energy-saving benefits of using solar heated water in your home.

American Solar Energy Society

2001-06-19T23:59:59.000Z

84

Commonwealth Solar Hot Water Residential Program | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heating Water Heating Maximum Rebate 3,500 per building or 25% of total installed costs Program Information Funding Source Massachusetts Renewable Energy Trust Fund Start Date...

85

Residential hot water distribution systems: Roundtable session  

E-Print Network (OSTI)

include: combustion and standby losses from water heaters,System Efficiency Losses Standby Loss Combustion LossBecause of their very low standby losses they can achieve

Lutz, James D.; Klein, Gary; Springer, David; Howard, Bion D.

2002-01-01T23:59:59.000Z

86

DOE Solar Decathlon: News Blog » Hot Water  

NLE Websites -- All DOE Office Websites (Extended Search)

'Hot Water' 'Hot Water' New Contest Data Displays Provide Insight into Competition Scoring Saturday, October 5, 2013 By Solar Decathlon New contest data displays are now available on the U.S. Department of Energy Solar Decathlon website. If you are interested in the real-time performance of each house and want to keep a close eye on the competition, check out the Contests section pages. In the Contests section, the pages for the measured contests (Comfort Zone, Hot Water, Appliances, Home Entertainment, and Energy Balance) explain the contest requirements and provide real-time graphical displays of the accumulated measurements/scores for each team. Roll your cursor over the graphics to see more detailed information about each contest. For example, in the Appliances Contest graphic, the scores for running the refrigerator,

87

Catalytic Behavior of Dense Hot Water  

DOE Green Energy (OSTI)

Water is known to exhibit fascinating physical properties at high pressures and temperatures. Its remarkable structural and phase complexity suggest the possibility of exotic chemical reactivity under extreme conditions, though this remains largely unstudied. Detonations of high explosives containing oxygen and hydrogen produce water at thousands of K and tens of GPa, similar to conditions of giant planetary interiors. These systems thus provide a unique means to elucidate the chemistry of 'extreme water'. Here we show that water plays an unexpected role in catalyzing complex explosive reactions - contrary to the current view that it is simply a stable detonation product. Using first-principles atomistic simulations of the detonation of high explosive pentaerythritol tetranitrate (PETN), we discovered that H{sub 2}O (source), H (reducer) and OH (oxidizer) act as a dynamic team that transports oxygen between reaction centers. Our finding suggests that water may catalyze reactions in other explosives and in planetary interiors.

Wu, C J; Fried, L E; Yang, L H; Goldman, N; Bastea, S

2008-06-05T23:59:59.000Z

88

Solar hot water system installed at Anderson, South Carolina  

DOE Green Energy (OSTI)

The solar energy hot water system installed in the Days Inns of America, Inc., at Anderson, South Carolina is described. The building is a low-rise two-story 114-room motel. The solar components were partly funded by the Department of Energy. The solar system was designed to provide 40% of the total hot water demand. The collector is a flat plate, liquid with an area of 750 square feet. Operation of this system was begun in November 1977, and has performed flawlessly for one year.

Not Available

1978-12-01T23:59:59.000Z

89

CPS Energy- Solar Hot Water Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

As part of a larger program designed to reduce electricity demand within its service territory, CPS Energy now offers rebates for solar water heaters to its customers. In general, any CPS Energy...

90

Commonwealth Solar Hot Water Residential Program (Massachusetts...  

Open Energy Info (EERE)

Low Emission Development Strategies Oil & Gas Smart Grid Solar U.S. OpenLabs Utilities Water Wind Page Actions View form View source History View New Pages Recent Changes All...

91

Commonwealth Solar Hot Water Commercial Program (Massachusetts...  

Open Energy Info (EERE)

Low Emission Development Strategies Oil & Gas Smart Grid Solar U.S. OpenLabs Utilities Water Wind Page Actions View form View source History View New Pages Recent Changes All...

92

LARGO hot water system thermal performance test report  

DOE Green Energy (OSTI)

The thermal performance tests and results on the LARGO Solar Hot Water System under natural environmental conditions are presented. Some objectives of these evaluations are to determine the amount of energy collected, the amount of energy delivered to the household as contributed by solar power supplied to operate the system and auxiliary power to maintain tank temperature at proper level, overall system efficiency and to determine temperature distribution within the tank. The tests and evaluation were performed at the Marshall Space Flight Center solar test facility. The Solar Hot Water system is termed a ''Dump-type'' because of the draining system for freeze protection. The solar collector is a single glazed flat plate. An 82-gallon domestic water heater is provided as the energy storage vessel. Water is circulated through the collector and water heater by a 5.3 GPM capacity pump, and control of the pump motor is achieved by a differential temperature controller.

Not Available

1978-11-01T23:59:59.000Z

93

Waste heat from kitchen cuts hot water electricity 23%  

SciTech Connect

Heat recovered from the Hamburger Hamlet's kitchen in Bethesada, Maryland and used to pre-heat the million gallons of hot water used annually reduced hot water costs 23% and paid off the investment in 1.5 years. Potomac Electric initiated the installation of an air-to-water heat pump in the restaurant kitchen above the dishwasher at a cost of about $5300, with the restaurant obliged to reimburse the utility if performance was satisfactory. Outside water recirculates through storage tanks and the ceiling heat pump until it reaches the required 140/sup 0/F. The amount of electricity needed to bring the preheated water to that temperature was $3770 lower after the installation. Cooled air exhausted from the heat pump circulates throughout the kitchen.

Barber, J.

1984-05-21T23:59:59.000Z

94

grid drawing  

Science Conference Proceedings (OSTI)

NIST. grid drawing. (definition). Definition: A graph drawing in which each vertex is represented by a point with integer coordinates. ...

2013-08-23T23:59:59.000Z

95

New hot-water use data for commercial buildings  

Science Conference Proceedings (OSTI)

This article reports that researchers have found that hot water usage in certain commercial buildings may be significantly higher than designers expect. ASHRAE Technical Committee 6.6, Service Water Heating, recognized the need for a comprehensive compilation and evaluation of available hot water usage information in residential and commercial installations. The bulk of the commercial building hot water demand and sizing information presented in Chapter 44 of the 1991 ASHRAE Handbook--HVAC Application is based on a comprehensive study published in 1969. However, information received by members of TC 6.6 and data appearing in some of the current literature suggest that the Handbook values may be too conservative. Because of conflicting information in the literature and possible variations in lifestyles and use patterns since the Handbook values were originally published, ASHRAE sponsored research project RP-600 to study and review these issues. In this research project, domestic hot water consumption was monitored at five separate commercial buildings in four building category types: one nursing home, two dormitories (one coed and one women's), one full-service restaurant and one hotel.

Thrasher, W.H.; DeWerth, D.W. (American Gas Association Lab., Cleveland, OH (United States))

1994-09-01T23:59:59.000Z

96

Solar heating/cooling and domestic hot-water systems  

Science Conference Proceedings (OSTI)

Increasing awareness of global warming forces policy makers and industries to face two challenges: reducing greenhouse gas emissions and securing stable energy supply against ever-increasing world energy consumption, which is projected to increase by ... Keywords: buildings heating, domestic hot-water, energetical analysis, renewable energy sources, solar cooling technologies, solar energy collection, solar thermal systems

Ioan Srbu; Marius Adam

2011-02-01T23:59:59.000Z

97

Large scale solar hot water heating systems for green hospital  

Science Conference Proceedings (OSTI)

Concerns over the impact of the environment on the massive usage of fossil fuels, combined with soaring energy prices, triggered increased interest in the use of solar energy. Solar energy is abundant, provides an important saving to the consumer, and ... Keywords: energy savings, evacuated tubes, greenhouse gas reduction, solar assisted hot water heaters

Poorya Ooshaksaraei; Baharudin Ali; Sohif Mat; M. Yahya; Kamaruzaman Ibrahim; Azami Zaharim; Kamaruzaman Sopian

2010-01-01T23:59:59.000Z

98

Ocala Utility Services - Solar Hot Water Heating Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Ocala Utility Services - Solar Hot Water Heating Rebate Program Ocala Utility Services - Solar Hot Water Heating Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Maximum Rebate One rebate per account Program Info State Florida Program Type Utility Rebate Program Rebate Amount $450 per system Provider Ocala Utility Services The Solar Water Heater Rebate Program is offered to residential retail electric customers by the City of Ocala Utility Services. Interested customers must complete an application and receive approval from the Ocala Utility Services before installing equipment. The application can be found on the [http://www.ocalafl.org/COO3.aspx?id=947 program web site.] The system must be installed by a licensed Florida contractor on the customer's

99

Solar heating and hot water system installed at Southeast of Saline, Unified School District 306, Mentor, Kansas  

DOE Green Energy (OSTI)

A cooperative agreement was negotiated in April 1978 for the installation of a space and domestic hot water system at Southeast of Saline, Kansas Unified School District 306, Mentor, Kansas. The solar system was installed in a new building and was designed to provide 52 percent of the estimated annual space heating load and 84 percent of the estimated annual potable hot water requirement. The collectors are liquid flat plate. They are ground-mounted and cover a total area of 5125 square feet. The system will provide supplemental heat for the school's closed-loop water-to-air heat pump system and domestic hot water. The storage medium is water inside steel tanks with a capacity of 11,828 gallons for space heating and 1,600 gallons for domestic hot water. This final report, which describes in considerable detail the solar heating facility, contains detailed drawings of the completed system. The facility was declared operational in September 1978, and has functioned successfully since.

Not Available

1979-07-01T23:59:59.000Z

100

Tapping Solar for Hot Water and Cheaper Bills for Puerto Rico...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tapping Solar for Hot Water and Cheaper Bills for Puerto Rico Tapping Solar for Hot Water and Cheaper Bills for Puerto Rico November 3, 2010 - 10:00am Addthis Stephen Graff Former...

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Evaluation of Residential Hot Water Distribution Ssytems by Numeric Simulation  

SciTech Connect

The objective of this project was to evaluate the performance and economics of various domestic hot water distribution systems in representative California residences. While the greatest opportunities for improved efficiency occur in new construction, significant improvements can also be made in some existing distribution systems. Specific objectives of the project tasks were: (1) Simulate potential energy savings of, perform cost-benefit analyses of, and identify market barriers to alternative new systems. (2) Simulate potential energy savings of, perform cost-benefit analyses of, and identify market barriers to maintenance, repair, and retrofit modifications of existing systems. (3) Evaluate potential impact of adopting alternative hot water distribution systems and report project findings. The outcome of this project is to provide homeowners, homebuilders, systems suppliers, municipal code officials and utility providers (both electric and water/sewer) with a neutral, independent, third party, cost-benefit analysis of alternative hot water distribution systems for use in California. The results will enable these stakeholders to make informed decisions regarding which system is most appropriate for use.

Wendt, ROBERT

2005-08-17T23:59:59.000Z

102

Direct Use for Building Heat and Hot Water Presentation Slides and Text Version  

Energy.gov (U.S. Department of Energy (DOE))

Download presentation slides from the DOE Office of Indian Energy webinar on direct use for building heat and hot water.

103

Water Heating: Energy-efficient strategies for supplying hot water in the home (BTS Technology Fact Sheet)  

SciTech Connect

Fact sheet for homeowners and contractors on how to supply hot water in the home while saving energy.

NAHB Research Center; Southface Energy Institute; U.S. Department of Energy' s Oak Ridge Laboratory; U.S. Department of Energy' s National Renewable Energy Laboratory

2001-08-15T23:59:59.000Z

104

Overheating in Hot Water- and Steam-Heated Multifamily Buildings  

Science Conference Proceedings (OSTI)

Apartment temperature data have been collected from the archives of companies that provide energy management systems (EMS) to multifamily buildings in the Northeast U.S. The data have been analyzed from more than 100 apartments in eighteen buildings where EMS systems were already installed to quantify the degree of overheating. This research attempts to answer the question, 'What is the magnitude of apartment overheating in multifamily buildings with central hot water or steam heat?' This report provides valuable information to researchers, utility program managers and building owners interested in controlling heating energy waste and improving resident comfort. Apartment temperature data were analyzed for deviation from a 70 degrees F desired setpoint and for variation by heating system type, apartment floor level and ambient conditions. The data shows that overheating is significant in these multifamily buildings with both hot water and steam heating systems.

Dentz, J.; Varshney, K.; Henderson, H.

2013-10-01T23:59:59.000Z

105

Improving thermosyphon solar domestic hot water system model performance. Final report, March 1994--February 1995  

DOE Green Energy (OSTI)

Data from an indoor solar simulator experimental performance test is used to develop a systematic calibration procedure for a computer model of a thermosyphoning, solar domestic hot water heating system with a tank-in-tank heat exchanger. Calibration is performed using an indoor test with a simulated solar collector to adjust heat transfer in the heat exchanger and heat transfer between adjacent layers of water in the storage tank. An outdoor test is used to calibrate the calculation of the friction drop in the closed collector loop. Additional indoor data with forced flow in the annulus of the heat exchanger leads to improved heat transfer correlations for the inside and outside regions of the tank-in-tank heat exchanger. The calibrated simulation model is compared to several additional outdoor tests both with and without auxiliary heating. Integrated draw energies are predicted with greater accuracy and draw temperature profiles match experimental results to a better degree. Auxiliary energy input predictions improve significantly. 63 figs., 29 tabs.

Swift, T.N.

1996-09-01T23:59:59.000Z

106

Controllers for solar domestic hot-water systems  

SciTech Connect

This document is intended as a resource for designers and installers of solar domestic hot water systems. It provides key functional control strategy and equipment alternatives and equipment descriptions adequate for writing effective DHW controller specifications. It also provides the installer with adequate technical background to understand the functional aspects of the controller. Included are specific instructions to install, check out, and troubleshoot the controller installation.

1981-10-01T23:59:59.000Z

107

Solar domestic hot water system inspection and performance evaluation handbook  

DOE Green Energy (OSTI)

A reference source and procedures are provided to a solar technician for inspecting a solar domestic hot water system after installation and for troubleshooting the system during a maintenance call. It covers six generic DHW systems and is designed to aid the user in identifying a system type, diagnosing a system's problem, and then pinpointing and evaluating specific component problems. A large amount of system design and installation information is also included.

Not Available

1981-10-01T23:59:59.000Z

108

Heating of Oil Well by Hot Water Circulation  

E-Print Network (OSTI)

When highly viscous oil is produced at low temperatures, large pressure drops will significantly decrease production rate. One of possible solutions to this problem is heating of oil well by hot water recycling. We construct and analyze a mathematical model of oil-well heating composed of three linear parabolic PDE coupled with one Volterra integral equation. Further on we construct numerical method for the model and present some simulation results.

Mladen Jurak; Zarko Prnic

2005-03-04T23:59:59.000Z

109

Solar Water Heating: What's Hot and What's Not  

E-Print Network (OSTI)

A handful of electric utilities in the United States now pay incentives to their customers to install solar water heaters or are developing programs to do so. The solar water heater incentives are part of a broader utility demand-side management program designed to reduce system demand during peak summer hours. Solar hot water has the potential to generate significant savings during periods of high solar intensity. For summer peaking utilities, these periods of high solar intensity coincide with the overall system peak. This paper discusses the basics of analyzing solar water heaters as a demand-side management measure. In addition, four utility solar water heater incentive programs are studied in detail. The paper describes each program and notes the stage of development. Where such information is available, incentive amounts and cost-effectiveness calculations are included.

Stein, J.

1992-05-01T23:59:59.000Z

110

Hotel in the Bahamas profits from solar hot water system  

SciTech Connect

On Paradise Island, located in the Bahamas, American Energy Technologies Inc. (AET) recently designed and supplied a domestic solar water heating system for the new Comfort Suites Hotel. AET is a Florida manufacturer of solar thermal collectors. The hotel has 150 rooms. Hot water usage entails the laundry facilities and the limited kitchen facilities. Access to hot showers is more of a luxury in some places, but guests at the Comfort Suites Hotel need not be concerned. During the development of the hotel, it was noted that the high heating costs of the propane-fueled hotel boiler were somewhat prohibitive. Propane cost approximately $1.67/gallon, causing the cost of heating water for the hotel to be estimated at over $1,000 per month. To offset the high heating costs, a 49-collector system on a 3200 gallon storage tank was designed into the plans for the new facility. The 49 roof mounted collectors were placed on a direct solar link to the 3200 gallon storage tank. The water is preheated before it gets to the boiler, cutting costs tremendously.

1993-01-01T23:59:59.000Z

111

Solar hot water systems for the southeastern United States: principles and construction of breadbox water heaters  

DOE Green Energy (OSTI)

The use of solar energy to provide hot water is among the easier solar technologies for homeowners to utilize. In the Southeastern United States, because of the mild climate and abundant sunshine, solar energy can be harnessed to provide a household's hot water needs during the non-freezing weather period mid-April and mid-October. This workbook contains detailed plans for building breadbox solar water heaters that can provide up to 65% of your hot water needs during warm weather. If fuel costs continue to rise, the annual savings obtained from a solar water heater will grow dramatically. The designs in this workbook use readily available materials and the construction costs are low. Although these designs may not be as efficient as some commercially available systems, most of a household's hot water needs can be met with them. The description of the breadbox water heater and other types of solar systems will help you make an informed decision between constructing a solar water heater or purchasing one. This workbook is intended for use in the southeastern United States and the designs may not be suitable for use in colder climates.

None

1983-02-01T23:59:59.000Z

112

Pumped Solar Domestic Hot Water (SDHW) system design guidelines  

SciTech Connect

This article provides practical guidelines based on experience gained from the design, installation, and commissioning of a pumped Solar Domestic Hot Water (SDHW) system in Saudi Arabia. The authors believe that such information is not readily available and will be useful to designers and installers of SDHW systems within the region. Since the current motivation for buying SDHW systems in Saudi Arabia is not strictly economic, it is imperative that a professional reference be available, against which the soundness of any technical decisions could be confirmed prior to their implementation. The intent is to ensure that systems designed and installed will operate reliably, therefore enhancing customer satisfaction.

Arshad, K.; Said, S.A.M. (King Fahd Univ. of Petroleum Minerals, Dhahran (Saudi Arabia))

1989-01-01T23:59:59.000Z

113

Residential hot water usage: A review of published metered studies. Topical report, August-December 1994  

SciTech Connect

The report presents a review of residential hot water usage studies. The studies included were published and publicly available, they measured actual hot water usage or energy usage, and they had sufficient demographic information to determine the number of people per household. The available hot water usage data were normalized to a 135 F setpoint temperature to eliminate the variations in usage caused by different water heater thermostat settings. Typical hot water usage as a function of family size was determined from linear regression analyses of the normalized metered studies` data points. A national average hot water usage of 53 gallons per day was determined from the regression analyses and census data on average household size. The review of metered studies also shows that there is no discernible difference in hot water usage for households with either electric or gas water heaters.

Paul, D.D.; Ide, B.E.; Hartford, P.A.

1994-12-01T23:59:59.000Z

114

Fort Hood Solar Total Energy Project. Volume III. Engineering drawings. Final report  

DOE Green Energy (OSTI)

Engineering drawings are presented for the Solar Total Energy System at Fort Hood, Texas. Drawings are given for the solar collector subsystem, power conversion subsystem, instrumentation and control subsystem, thermal storage subsystem, site preparation, thermal storage area piping and equipment layout, heating/cooling and domestic hot water subsystem, STES building and facility, and electrical distribution. (WHK)

None,

1979-01-01T23:59:59.000Z

115

Optimum hot water temperature for absorption solar cooling  

SciTech Connect

The hot water temperature that maximizes the overall instantaneous efficiency of a solar cooling facility is determined. A modified characteristic equation model is used and applied to single-effect lithium bromide-water absorption chillers. This model is based on the characteristic temperature difference and serves to empirically calculate the performance of real chillers. This paper provides an explicit equation for the optimum temperature of vapor generation, in terms of only the external temperatures of the chiller. The additional data required are the four performance parameters of the chiller and essentially a modified stagnation temperature from the detailed model of the thermal collector operation. This paper presents and discusses the results for small capacity machines for air conditioning of homes and small buildings. The discussion highlights the influence of the relevant parameters. (author)

Lecuona, A.; Ventas, R.; Venegas, M.; Salgado, R. [Dpto. Ingenieria Termica y de Fluidos, Universidad Carlos III de Madrid, Avda. Universidad 30, 28911 Leganes, Madrid (Spain); Zacarias, A. [ESIME UPA, IPN, Av. de las Granjas 682, Col. Santa Catarina, 02550, D.F. Mexico (Mexico)

2009-10-15T23:59:59.000Z

116

Water and Energy Wasted During Residential Shower Events: Findings from a Pilot Field Study of Hot Water Distribution Systems  

E-Print Network (OSTI)

study to determine waste of water and energy in residential30 percent. The average waste of energy in the hot water ispaper examines the waste of water and energy associated with

Lutz, Jim

2012-01-01T23:59:59.000Z

117

Direct uses of hot water (geothermal) in dairying  

DOE Green Energy (OSTI)

Digital computer simulation was used to investigate the peak, steady energy utilization of a geothermal energy-supported dairy. A digital computer program was also written to assess the lifetime economics of the dairy operation. A dynamic simulation program was written to design water storage tanks under diurnal transient loading. The geothermal site specified is the artesian spring named Hobo Wells near Susanville, California. The dairy configuration studies are unique, but consist of conventional processing equipment. In the dairy, cattle waste would be used to generate methane and carbon dioxide by anaerobic digestion. Some carbon dioxide would be removed from the gas stream with a pressurized water scrubber to raise the heating value. The product gas would be combusted in a spark ignition engine connected to an electric generator. The electrical power produced would be used for operation of fans, pumps, lights and other equipment in the dairy. An absorption chiller using a geothermal water driven generator would provide milk chilling. Space heating would be done with forced air hot water unit heaters.

Barmettler, E.R.; Rose, W.R. Jr.

1978-01-01T23:59:59.000Z

118

Rock-Water Interactions In Hot Dry Rock Geothermal Systems- Field...  

Open Energy Info (EERE)

Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon Rock-Water Interactions In Hot Dry Rock Geothermal Systems- Field Investigations Of In Situ...

119

graph drawing  

Science Conference Proceedings (OSTI)

... Layout Program (C). Graphviz: Graph Visualization Software (C), consisting of many graph drawing programs, viewers (C, Java, and TCL/TK), etc. ...

2013-11-18T23:59:59.000Z

120

EERE Roofus' Solar and Efficient Home: Solar Hot Water  

NLE Websites -- All DOE Office Websites (Extended Search)

of Roofus, a golden retriever, sitting in front of three black, rectangular solar collectors. Sunshine is really hot, and it makes my roof get hot, too So I use a...

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Affordable Solar Hot Water and Power LLC | Open Energy Information  

Open Energy Info (EERE)

Water and Power LLC Water and Power LLC Jump to: navigation, search Name Affordable Solar Hot Water and Power LLC Place Dothan, Alabama Zip 36305 Sector Solar Product Solar and Energy Efficiency for buildings and homes Year founded 2006 Number of employees 1-10 Phone number 334-828-1024 Website http://www.asolarpro.com Coordinates 31.2070554°, -85.4994192° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":31.2070554,"lon":-85.4994192,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

122

Building America Top Innovations Hall of Fame Profile … Model Simulating Real Domestic Hot Water Use  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

and the Davis Energy Group used the and the Davis Energy Group used the Domestic Hot Water Event Schedule Generator to accurately quantify effects of low and high water usage on distribution system measures such as pipe insulation, home run plumbing, and demand-controlled recirculation loops. As progress continues with high-R, tightly sealed thermal enclosures, domestic hot water becomes an increasingly important energy use in high-performance homes. Building America research has improved our ability to model hot water use so new hot water technologies can be more accurately assessed and more readily integrated into high-performance homes. Energy savings for certain residential building technologies depend greatly on occupant behavior. Domestic hot water use is a good example. Simulating

123

Prototype solar heating and cooling systems including potable hot water. Quarterly reports  

DOE Green Energy (OSTI)

The activities conducted by Solaron Corporation from November 1977 through September 1978 are summarized and the progress made in the development, delivery and support of two prototype solar heating and cooling systems including potable hot water is covered. The system consists of the following subsystems: solar collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition.

Williamson, R.

1978-10-01T23:59:59.000Z

124

Prototype solar heating and cooling systems including potable hot water. Quarterly reports, November 1976--June 1977  

DOE Green Energy (OSTI)

This report covers the progress made in the development, delivery and support of two prototype solar heating and cooling systems including potable hot water. The system consists of the following subsystems: collector, auxiliary heating, potable hot water, storage, control, transport, and government-furnished site data acquisition.

Not Available

1978-12-01T23:59:59.000Z

125

Development of Standardized Domestic Hot Water Event Schedules for Residential Buildings  

SciTech Connect

The Building America Research Benchmark is a standard house definition created as a point of reference for tracking progress toward multi-year energy savings targets. As part of its development, the National Renewable Energy Laboratory has established a set of domestic hot water events to be used in conjunction with sub-hourly analysis of advanced hot water systems.

Hendron, R.; Burch, J.

2008-08-01T23:59:59.000Z

126

Hot Corrosion of Shipboard Turbine Components in High Water ...  

Science Conference Proceedings (OSTI)

While the resulting degradation for the two types of hot corrosion has been well documented for traditional fuel ... Hardware Materials in Carbonate Fuel Cell.

127

Water geochemistry and hydrogeology of the shallow aquifer at Roosevelt Hot Springs, southern Utah: A hot dry rock prospect  

DOE Green Energy (OSTI)

On the western edge of the geothermal field, three deep holes have been drilled that are very hot but mostly dry. Two of them (Phillips 9-1 and Acord 1-26 wells) have been studied by Los Alamos National Laboratory for the Hot Dry Rock (HDR) resources evaluation program. A review of data and recommendations have been formulated to evaluate the HDR geothermal potential at Roosevelt. The present report is directed toward the study of the shallow aquifer of the Milford Valley to determine if the local groundwater would be suitable for use as make-up water in an HDR system. This investigation is the result of a cooperative agreement between Los Alamos and Phillips Petroleum Co., formerly the main operator of the Roosevelt Hot Springs Unit. The presence of these hot dry wells and the similar setting of the Roosevelt area to the prototype HDR site at Fenton Hill, New Mexico, make Roosevelt a very good candidate site for creation of another HDR geothermal system. This investigation has two main objectives: to assess the water geochemistry of the valley aquifer, to determine possible problems in future make-up water use, such as scaling or corrosion in the wells and surface piping, and to assess the hydrogeology of the shallow groundwaters above the HDR zone, to characterize the physical properties of the aquifer. These two objectives are linked by the fact that the valley aquifer is naturally contaminated by geothermal fluids leaking out of the hydrothermal reservoir. In an arid region where good-quality fresh water is needed for public water supply and irrigation, nonpotable waters would be ideal for an industrial use such as injection into an HDR energy extraction system. 50 refs., 10 figs., 10 tabs.

Vuataz, F.D.; Goff, F.

1987-12-01T23:59:59.000Z

128

Waters of Hot Springs National Park, Arkansas: their nature and origin  

DOE Green Energy (OSTI)

The 47 hot springs of Hot Springs National Park, Arkansas, issue from the plunging crestline of a large overturned anticline, along the southern margin of the Ouachita anticlinorium, in the Zigzag Mountains. The combined flow of the hot springs ranges from 750,000 to 950,000 gallons per day (3.29 x 10/sup -2/ to 4.16 x 10/sup -2/ cubic meters per second). The radioactivity and chemical composition of the hot-water springs are similar to that of the cold-water springs and wells in the area. The tritium and carbon-14 analyses of the water indicate that the water is a mixture of a very small amount of water less than 20 years old and a preponderance of water about 4400 years old. The presence of radium and radon in the hot-springs waters has been established by analyses. Mathematical models were employed to test various conceptual models of the hot-springs flow system. The geochemical data, flow measurements, and geologic structure of the region support the concept that virtually all the hot-springs water is of local, meteoric origin. Recharge to the hot-springs artesian-flow system is by infiltration of rainfall in the outcrop areas of the Bigfork Chert and the Arkansas Novaculite. The water moves slowly to depth where it is heated by contact with rocks of high temperature. Highly permeable zones, related to jointing or faulting, collect the heated water in the aquifer and provide avenues for the water to travel rapidly to the surface.

Bedinger, M.S.; Pearson, F.J. Jr.; Reed, J.E.; Sniegocki, R.T.; Stone, C.G.

1979-01-01T23:59:59.000Z

129

A search for the Mpemba effect: When hot water freezes faster then cold water James D. Brownridge  

E-Print Network (OSTI)

..." and "...Preheating the melt produces no certain effect upon it ..."6 In other words, if a specimen of water voltage produced the when latent heat of freezing is released. (A) Glass tube and water, (B) 500k, (CA search for the Mpemba effect: When hot water freezes faster then cold water James D. Brownridge

Suzuki, Masatsugu

130

DOE Office of Indian Energy Foundational Course on Direct Use for Building Heat and Hot Water  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Direct Use for Building Direct Use for Building Heat and Hot Water Webinar (text version) Below is the text version of the Webinar titled "DOE Office of Indian Energy Foundational Courses Renewable Energy Technologies: Direct Use for Building Heat and Hot Water." Slide 1 Amy Hollander: Hello, I'm Amy Hollander with the National Renewable Energy Laboratory. Welcome to today's webinar on Building Heat and Hot Water sponsored by the U.S. Department of Energy Office of Indian Energy Policy and Programs. This webinar is being recorded from DOE's National Renewable Energy Laboratory's new state-of-the-art net zero

131

Apparatus and method for pumping hot, erosive slurry of coal solids in coal derived, water immiscible liquid  

SciTech Connect

An apparatus for and method of pumping hot, erosive slurry of coal solids in a coal derived, water immiscible liquid to higher pressure involves the use of a motive fluid which is miscible with the liquid of the slurry. The apparatus includes a pump 12, a remote check valve 14 and a chamber 16 between and in fluid communication with the pump 12 and check valve 14 through conduits 18,20. Pump 12 exerts pressure on the motive fluid and thereby on the slurry through a concentration gradient of coal solids within chamber 16 to alternately discharge slurry under pressure from the outlet port of check valve 14 and draw slurry in through the inlet port of check valve 14.

Ackerman, Carl D. (Olympia, WA)

1983-03-29T23:59:59.000Z

132

Performance of Heat Pump Water Heaters: Initial Findings of Draw Profile Effect on HPWH Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Performance of Heat Pump Water Heaters Performance of Heat Pump Water Heaters © 2011 Steven Winter Associates, Inc. All rights reserved. © 2011 Steven Winter Associates, Inc. All rights reserved. Evaluation Overview  2000-2002 Evaluated 20 installations with CL&P  Product had problems; not ready for prime time (average COPs of 1.67 was not the problem)  New batch of heaters available, including:  GE's GeoSpring Hybrid (50 gal)  A.O.Smith's Voltex Hybrid (60 & 80 gal)  Stiebel-Eltron's Accelera 300 (80 gal)  Evaluating 14 installations for National Grid, NSTAR, & Cape Light Compact. © 2011 Steven Winter Associates, Inc. All rights reserved. © 2011 Steven Winter Associates, Inc. All rights reserved.

133

Final report : testing and evaluation for solar hot water reliability.  

DOE Green Energy (OSTI)

Solar hot water (SHW) systems are being installed by the thousands. Tax credits and utility rebate programs are spurring this burgeoning market. However, the reliability of these systems is virtually unknown. Recent work by Sandia National Laboratories (SNL) has shown that few data exist to quantify the mean time to failure of these systems. However, there is keen interest in developing new techniques to measure SHW reliability, particularly among utilities that use ratepayer money to pay the rebates. This document reports on an effort to develop and test new, simplified techniques to directly measure the state of health of fielded SHW systems. One approach was developed by the National Renewable Energy Laboratory (NREL) and is based on the idea that the performance of the solar storage tank can reliably indicate the operational status of the SHW systems. Another approach, developed by the University of New Mexico (UNM), uses adaptive resonance theory, a type of neural network, to detect and predict failures. This method uses the same sensors that are normally used to control the SHW system. The NREL method uses two additional temperature sensors on the solar tank. The theories, development, application, and testing of both methods are described in the report. Testing was performed on the SHW Reliability Testbed at UNM, a highly instrumented SHW system developed jointly by SNL and UNM. The two methods were tested against a number of simulated failures. The results show that both methods show promise for inclusion in conventional SHW controllers, giving them advanced capability in detecting and predicting component failures.

Caudell, Thomas P. (University of New Mexico, Albuquerque, NM); He, Hongbo (University of New Mexico, Albuquerque, NM); Menicucci, David F. (Building Specialists, Inc., Albuquerque, NM); Mammoli, Andrea A. (University of New Mexico, Albuquerque, NM); Burch, Jay (National Renewable Energy Laboratory, Golden CO)

2011-07-01T23:59:59.000Z

134

Geothermal: Sponsored by OSTI -- Residential hot water distribution...  

Office of Scientific and Technical Information (OSTI)

Technologies Legacy Collection HelpFAQ | Site Map | Contact Us | Admin Log On HomeBasic Search About Publications Advanced Search New Hot Docs News Related Links You are...

135

Estimating market penetration of steam, hot water and chilled water in commercial sector using a new econometric model  

SciTech Connect

For the first time in the public domain, we have estimated the energy consumption and expenditures of district steam, hot water, and chilled water. Specifically, the combined energy consumption and expenditures of steam, hot water, and chilled water in 1989 were approximately 800 trillion Btu and 7 billion dollars, respectively. The purpose of this paper is to introduce a new model developed at Argonne National Laboratory (ANL) for estimating market penetration of steam, hot water, and chilled water systems in commercial buildings over the next 20 years. This research sponsored by the US Department of Energy (DOE) used the 1989 Commercial Building Energy Consumption Surveys (CBECS) to provide information on energy consumption and expenditures and related factors in about 6000 buildings. A general linear model to estimated parameters for each of the three equations for steam, hot water, and chilled water demand in the buildings. A logarithmic transformation was made for the dependent variable and most of the explanatory variables. The model provides estimates of building steam, hot water, and chilled water consumption and expenditures between now and the year 2010. This model should be of interest to policymakers, researchers, and market participants involved with planning and implementing community-based energy-conserving and environmentally beneficial energy systems.

Teotia, A.P.S.; Karvelas, D.E.; Daniels, E.J.; Anderson, J.L.

1993-08-01T23:59:59.000Z

136

Solar Hot Water Technology: Office of Power Technologies (OPT) Success Stories Series Fact Sheet  

NLE Websites -- All DOE Office Websites (Extended Search)

Buildings Program Buildings Program Office of Solar Energy Technologies Every home, commercial building, and indus- trial facility requires hot water. An enormous amount of energy is consumed in the United States producing and maintaining our supply of on-demand hot water; the residential and commercial sectors combined use 3 quads (quadrillion Btus) of energy per year, roughly 3% of the total U.S. energy consumption. As of 1998, 1.2 million systems have been installed on homes in the United States, with 6000 currently being added each year. Yet the potential for growth is huge, as solar hot water systems are supplying less than 2% of the nation's hot water. For industrial applications, the growth potential lies in large-scale systems, using flat-plate and trough-type collectors which are being installed in increasing numbers in

137

Tribal Renewable Energy Foundational Course: Direct Use for Building Heat and Hot Water  

Energy.gov (U.S. Department of Energy (DOE))

Watch the U.S. Department of Energy Office of Indian Energy foundational course webinar on direct use for building heat and hot water by clicking on the .swf link below. You can also download the...

138

Water Sampling At Hot Lake Area (Wood, 2002) | Open Energy Information  

Open Energy Info (EERE)

Hot Lake Area (Wood, 2002) Hot Lake Area (Wood, 2002) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Water Sampling At Hot Lake Area (Wood, 2002) Exploration Activity Details Location Hot Lake Area Exploration Technique Water Sampling Activity Date Usefulness could be useful with more improvements DOE-funding Unknown Notes Geothermal fluids from hot springs and wells have been sampled from a number of locations, including: 1) the North Island of New Zealand (three sets of samples from three different years) and the South Island of New Zealand (1 set of samples); 2) the Cascades of Oregon; 3) the Harney, Alvord Desert and Owyhee geothermal areas of Oregon; 4) the Dixie Valley and Beowawe fields in Nevada; 5) Palinpiiion, the Philippines; 6) the Salton Sea and Heber geothermal fields of southern California; and 7) the

139

Water Sampling At Crane Hot Springs Area (Wood, 2002) | Open Energy  

Open Energy Info (EERE)

Hot Springs Area (Wood, 2002) Hot Springs Area (Wood, 2002) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Water Sampling At Crane Hot Springs Area (Wood, 2002) Exploration Activity Details Location Crane Hot Springs Area Exploration Technique Water Sampling Activity Date Usefulness could be useful with more improvements DOE-funding Unknown Notes Geothermal fluids from hot springs and wells have been sampled from a number of locations, including: 1) the North Island of New Zealand (three sets of samples from three different years) and the South Island of New Zealand (1 set of samples); 2) the Cascades of Oregon; 3) the Harney, Alvord Desert and Owyhee geothermal areas of Oregon; 4) the Dixie Valley and Beowawe fields in Nevada; 5) Palinpiiion, the Philippines; 6) the

140

Water Sampling At Mccredie Hot Springs Area (Wood, 2002) | Open Energy  

Open Energy Info (EERE)

Mccredie Hot Springs Area (Wood, 2002) Mccredie Hot Springs Area (Wood, 2002) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Water Sampling At Mccredie Hot Springs Area (Wood, 2002) Exploration Activity Details Location Mccredie Hot Springs Area Exploration Technique Water Sampling Activity Date Usefulness could be useful with more improvements DOE-funding Unknown Notes Geothermal fluids from hot springs and wells have been sampled from a number of locations, including: 1) the North Island of New Zealand (three sets of samples from three different years) and the South Island of New Zealand (1 set of samples); 2) the Cascades of Oregon; 3) the Harney, Alvord Desert and Owyhee geothermal areas of Oregon; 4) the Dixie Valley and Beowawe fields in Nevada; 5) Palinpiiion, the Philippines; 6) the

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Installation package for a domestic solar heating and hot water system  

DOE Green Energy (OSTI)

Fern Engineering Company, Inc. has developed two prototype solar heating and hot water systems. The systems have been installed at Tunkhannock, Pennsylvania, and Lansing, Michigan. The system consists of the following subsystems: solar collector, storage, control, transport, and auxiliary energy. General guidelines which may be utilized in development of detailed installation plans and specifications are presented. In addition, instruction on operation, maintenance, and repair of a solar heating and hot water system is provided.

Not Available

1978-08-01T23:59:59.000Z

142

Recovery of energy from geothermal brine and other hot water sources  

DOE Patents (OSTI)

Process and system for recovery of energy from geothermal brines and other hot water sources, by direct contact heat exchange between the brine or hot water, and an immiscible working fluid, e.g. a hydrocarbon such as isobutane, in a heat exchange column, the brine or hot water therein flowing countercurrent to the flow of the working fluid. The column can be operated at subcritical, critical or above the critical pressure of the working fluid. Preferably, the column is provided with a plurality of sieve plates, and the heat exchange process and column, e.g. with respect to the design of such plates, number of plates employed, spacing between plates, area thereof, column diameter, and the like, are designed to achieve maximum throughput of brine or hot water and reduction in temperature differential at the respective stages or plates between the brine or hot water and the working fluid, and so minimize lost work and maximize efficiency, and minimize scale deposition from hot water containing fluid including salts, such as brine. Maximum throughput approximates minimum cost of electricity which can be produced by conversion of the recovered thermal energy to electrical energy.

Wahl, III, Edward F. (Claremont, CA); Boucher, Frederic B. (San Juan Capistrano, CA)

1981-01-01T23:59:59.000Z

143

Tapping Solar for Hot Water and Cheaper Bills for Puerto Rico | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tapping Solar for Hot Water and Cheaper Bills for Puerto Rico Tapping Solar for Hot Water and Cheaper Bills for Puerto Rico Tapping Solar for Hot Water and Cheaper Bills for Puerto Rico November 3, 2010 - 10:00am Addthis Stephen Graff Former Writer & editor for Energy Empowers, EERE What does this mean for me? 150 new jobs. 1200 solar water heaters installed. In Puerto Rico, solar water heaters have been popular for decades. But even with energy savings, not everyone can afford one. Through a new Recovery Act-funded program for the island, more families are showering with water heated by the sun. The U.S. Department of Energy's new Weatherization Assistance Program (WAP) in Puerto Rico has made it a priority to install the systems in homes of income-eligible residents, as part of its weatherization assistance services. The Puerto Rico Energy Affairs Administration (PREAA), which

144

Water Sampling At Alvord Hot Springs Area (Wood, 2002) | Open Energy  

Open Energy Info (EERE)

Water Sampling At Alvord Hot Springs Area (Wood, Water Sampling At Alvord Hot Springs Area (Wood, 2002) Exploration Activity Details Location Alvord Hot Springs Area Exploration Technique Water Sampling Activity Date Usefulness could be useful with more improvements DOE-funding Unknown Notes Geothermal fluids from hot springs and wells have been sampled from a number of locations, including: 1) the North Island of New Zealand (three sets of samples from three different years) and the South Island of New Zealand (1 set of samples); 2) the Cascades of Oregon; 3) the Harney, Alvord Desert and Owyhee geothermal areas of Oregon; 4) the Dixie Valley and Beowawe fields in Nevada; 5) Palinpiiion, the Philippines; 6) the Salton Sea and Heber geothermal fields of southern California; and 7) the Dieng field in Central Java, Indonesia. We have analyzed the samples from

145

Water Sampling At Beowawe Hot Springs Area (Wood, 2002) | Open Energy  

Open Energy Info (EERE)

Water Sampling At Beowawe Hot Springs Area (Wood, Water Sampling At Beowawe Hot Springs Area (Wood, 2002) Exploration Activity Details Location Beowawe Hot Springs Area Exploration Technique Water Sampling Activity Date Usefulness could be useful with more improvements DOE-funding Unknown Notes Geothermal fluids from hot springs and wells have been sampled from a number of locations, including: 1) the North Island of New Zealand (three sets of samples from three different years) and the South Island of New Zealand (1 set of samples); 2) the Cascades of Oregon; 3) the Harney, Alvord Desert and Owyhee geothermal areas of Oregon; 4) the Dixie Valley and Beowawe fields in Nevada; 5) Palinpiiion, the Philippines; 6) the Salton Sea and Heber geothermal fields of southern California; and 7) the Dieng field in Central Java, Indonesia. We have analyzed the samples from

146

New Hampshire Electric Co-Op - Solar Hot Water | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

New Hampshire Electric Co-Op - Solar Hot Water New Hampshire Electric Co-Op - Solar Hot Water New Hampshire Electric Co-Op - Solar Hot Water < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Maximum Rebate $1,500 Program Info State New Hampshire Program Type Utility Rebate Program Rebate Amount 20% of installed costs Provider New Hampshire Electric Co-Op New Hampshire Electric Co-Op (NHEC) offers rebates to residential customers who install qualified solar water-heating systems. The rebate is equal to 20% of installed system costs, with a maximum award of $1,500. Systems must be pre-approved, and installed in NHEC's service territory by a qualified installer. Program funds are available on a first-come, first-served basis. See the program web site listed above for more information, an application

147

Measured electric hot water standby and demand loads from Pacific Northwest homes  

SciTech Connect

The Bonneville Power Administration began the End-Use Load and Consumer Assessment Program (ELCAP) in 1983 to obtain metered hourly end-use consumption data for a large sample of new and existing residential and commercial buildings in the Pacific Northwest. Loads and load shapes from the first 3 years of data fro each of several ELCAP residential studies representing various segments of the housing population have been summarized by Pratt et al. The analysis reported here uses the ELCAP data to investigate in much greater detail the relationship of key occupant and tank characteristics to the consumption of electricity for water heating. The hourly data collected provides opportunities to understand electricity consumption for heating water and to examine assumptions about water heating that are critical to load forecasting and conservation resource assessments. Specific objectives of this analysis are to: (A) determine the current baseline for standby heat losses by determining the standby heat loss of each hot water tank in the sample, (B) examine key assumptions affecting standby heat losses such as hot water temperatures and tank sizes and locations, (C) estimate, where possible, impacts on standby heat losses by conservation measures such as insulating tank wraps, pipe wraps, anticonvection valves or traps, and insulating bottom boards, (D) estimate the EF-factors used by the federal efficiency standards and the nominal R-values of the tanks in the sample, (E) develop estimates of demand for hot water for each home in the sample by subtracting the standby load from the total hot water load, (F) examine the relationship between the ages and number of occupants and the hot water demand, (G) place the standby and demand components of water heating electricity consumption in perspective with the total hot water load and load shape.

Pratt, R.G.; Ross, B.A.

1991-11-01T23:59:59.000Z

148

New Infographic and Projects to Keep Your Energy Bills Out of Hot Water |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Infographic and Projects to Keep Your Energy Bills Out of Hot Infographic and Projects to Keep Your Energy Bills Out of Hot Water New Infographic and Projects to Keep Your Energy Bills Out of Hot Water April 19, 2013 - 3:21pm Addthis New Energy Saver 101 infographic lays out the different types of water heaters on the market and will help you figure out how to select the best model for your home. Download a high-resolution version of the infographic. | Infographic by Sarah Gerrity. New Energy Saver 101 infographic lays out the different types of water heaters on the market and will help you figure out how to select the best model for your home. Download a high-resolution version of the infographic. | Infographic by Sarah Gerrity. Rebecca Matulka Rebecca Matulka Digital Communications Specialist, Office of Public Affairs

149

Water Sampling At Buffalo Valley Hot Springs Area (Laney, 2005) | Open  

Open Energy Info (EERE)

Water Sampling At Buffalo Valley Hot Springs Area Water Sampling At Buffalo Valley Hot Springs Area (Laney, 2005) Exploration Activity Details Location Buffalo Valley Hot Springs Area Exploration Technique Water Sampling Activity Date Usefulness not indicated DOE-funding Unknown Notes Geochemical Sampling of Thermal and Non-thermal Waters in Nevada, Shevenell and Garside. The objective of this project is to obtain geochemical data from springs (and some wells) for which data are not publicly available, or for which the analyses are incomplete, poor, or nonexistent. With these data, geothermometers are being calculated and a preliminary assessment of the geothermal potential and ranking of the sampled areas is being conducted using the new geochemical data. Objectives changed slightly in 2004. Samples are now being collected at sites identified by other

150

Solar heating and hot water system installed at Cherry Hill, New Jersey. [Hotels  

DOE Green Energy (OSTI)

The solar heating and hot water system installed in existing buildings at the Cherry Hill Inn in Cherry Hill, New Jersey is described in detail. The system went into operation November 8, 1978 and is expected to furnish 31.5% of the overall heating load and 29.8% of the hot water load. The collectors are General Electric Company liquid evacuated tube type. The storage system is an above ground insulated steel water tank with a capacity of 7,500 gallons.

Not Available

1979-05-16T23:59:59.000Z

151

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

SciTech Connect

Residential water heating is a large source of energy use in California homes. This project took a life cycle approach to comparing tank and tankless water heaters in Northern and Southern California. Information about the life cycle phases was calculated using the European Union?s Methodology study for EcoDesign of Energy-using Products (MEEUP) and the National Renewable Energy Laboratory?s Life Cycle Inventory (NREL LCI) database. In a unit-to-unit comparison, it was found that tankless water heaters would lessen impacts of water heating by reducing annual energy use by 2800 MJ/year (16% compared to tank), and reducing global warming emissions by 175 kg CO2 eqv./year (18% reduction). Overall, the production and combustion of natural gas in the use phase had the largest impact. Total waste, VOCs, PAHs, particulate matter, and heavy-metals-to-air categories were also affected relatively strongly by manufacturing processes. It was estimated that tankless water heater users would have to use 10 more gallons of hot water a day (an increased usage of approximately 20%) to have the same impact as tank water heaters. The project results suggest that if a higher percentage of Californians used tankless water heaters, environmental impacts caused by water heating would be smaller.

Lu, Alison; McMahon, James; Masanet, Eric; Lutz, Jim

2008-08-13T23:59:59.000Z

152

Commissioning the Domestic Hot Water System on a Large University Campus: A Case Study  

E-Print Network (OSTI)

The Texas A&M University (TAMU) main campus in College Station consists of 110 buildings with 12.5 million square feet of gross building space. Seventy-one of these buildings are connected to the main campus domestic hot water (DHW) distribution system. The DHW loop is more than 50 years old and has had continuing distribution problems. The main problems reported from several buildings were low hot water temperature and long delays in obtaining hot water at fixtures. The objective of this study was to investigate the causes of these problems and help determine how to best operate the system. It was found that reported problems of low flows, low temperatures and long hot water lag time resulted from reverse flows and no hot water circulation caused by: 1) Unadjusted return pumps with heads too high. 2) Pumps not installed or not running where needed. 3) Pumps with heads too low. 4) Check valves not installed where needed. 5) Insufficient piping capacity in two locations. This paper presents possible control strategies to alleviate these problems identified during the field investigation.

Chen, H.; Bensouda, N.; Claridge, D.; Bruner, H.

2004-01-01T23:59:59.000Z

153

Commercial Solar Hot Water Financing Program | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Nonprofit Schools State Government Savings Category Solar Buying & Making Electricity Heating & Cooling Commercial Heating & Cooling Water Heating Program Info State Massachusetts...

154

Rock-Water Interactions In Hot Dry Rock Geothermal Systems- Field  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Rock-Water Interactions In Hot Dry Rock Geothermal Systems- Field Investigations Of In Situ Geochemical Behavior Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Rock-Water Interactions In Hot Dry Rock Geothermal Systems- Field Investigations Of In Situ Geochemical Behavior Details Activities (5) Areas (2) Regions (0) Abstract: Two hot dry rock (HDR) geothermal energy reservoirs have been created by hydraulic fracturing of Precambrian granitic rock between two wells on the west flank of the Valles Caldera in the Jemez Mountains of northern New Mexico. Heat is extracted by injecting water into one well,

155

Why Is Nevada in Hot Water? Structural Controls and Tectonic Model of  

Open Energy Info (EERE)

Why Is Nevada in Hot Water? Structural Controls and Tectonic Model of Why Is Nevada in Hot Water? Structural Controls and Tectonic Model of Geothermal Systems in the Northwestern Great Basin Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Why Is Nevada in Hot Water? Structural Controls and Tectonic Model of Geothermal Systems in the Northwestern Great Basin Abstract In the western Great Basin, the Walker Lane is a system of right-lateral strike-slip faults accommodating ~15-25% of relative motion between the Pacific and North American plates. Relatively high rates of recent (<10 Ma) west-northwest extension absorb northwestward declining dextral motion in the Walker Lane, diffusing that motion into the Basin-Range. Abundant geothermal fields cluster in several northeasttrending belts in the

156

City of San Jose - Solar Hot Water Heaters and Photovoltaic Systems Permit  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

San Jose - Solar Hot Water Heaters and Photovoltaic Systems San Jose - Solar Hot Water Heaters and Photovoltaic Systems Permit Requirements City of San Jose - Solar Hot Water Heaters and Photovoltaic Systems Permit Requirements < Back Eligibility Commercial Construction Industrial Installer/Contractor Multi-Family Residential Residential Savings Category Solar Buying & Making Electricity Program Info State California Program Type Solar/Wind Permitting Standards Provider City of San Jose Building, Planning and Electrical Permits are required for Photovoltiac (PV) systems installed in San Jose. In most cases, PV systems must also undergo a Building Plan Review and an Electrical Plan Review. Building Plan Reviews are not required for installations that meet all of the following criteria: 1. Total panel weight (including frame) is not greater than 5 lbs. per

157

Experience on design and operation of hotel/motel solar hot water systems  

SciTech Connect

The use of solar energy to preheat domestic hot water in hotels and motels has many advantages. Year long use of these solar systems provides shorter payback periods. Temperature requirements for hotel/motel use are relatively low and are compatible with low cost flat plate collectors. Simple controls relate to higher reliability in both drain-down and heat exchanger configurations. Solar systems are easily retrofitted to most existing hotel/motel hot water systems and there are many hotels and motels across the country with roof area sufficient in size to hold the required collector arrays. Hotel/motel systems with payback periods of less than four years, which provide 70% of the total hot water load, are discussed.

Brohl, E.C.; Struss, R.G.; Sidles, P.H.

1978-01-01T23:59:59.000Z

158

Pattern Of Shallow Ground Water Flow At Mount Princeton Hot Springs,  

Open Energy Info (EERE)

Pattern Of Shallow Ground Water Flow At Mount Princeton Hot Springs, Pattern Of Shallow Ground Water Flow At Mount Princeton Hot Springs, Colorado, Using Geoelectrical Methods Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Pattern Of Shallow Ground Water Flow At Mount Princeton Hot Springs, Colorado, Using Geoelectrical Methods Details Activities (2) Areas (1) Regions (0) Abstract: In geothermal fields, open faults and fractures often act as high permeability pathways bringing hydrothermal fluids to the surface from deep reservoirs. The Mount Princeton area, in south-central Colorado, is an area that has an active geothermal system related to faulting and is therefore a suitable natural laboratory to test geophysical methods. The Sawatch range-front normal fault bordering the half-graben of the Upper Arkansas

159

Air Pollution Control Regulations: No. 13- Particulate Emissions from Fossil Fuel Fired Steam or Hot Water Generating Units (Rhode Island)  

Energy.gov (U.S. Department of Energy (DOE))

The purpose of this regulation is to limit emissions of particulate matter from fossil fuel fired and wood-fired steam or hot water generating units.

160

Solar heating of buildings and domestic hot water  

SciTech Connect

Design criteria and cost analysis methods are presented for the sizing and justification of solar heat collectors for augmentation of potable water heaters and space heaters. Sufficient information is presented to enable engineers to design solar space and water heating systems or conduct basic feasibility studies preparatory to design of large installations. Both retrofit and new installations are considered. (WDM)

Beck, E.J. Jr.; Field, R.L.

1976-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Opportunities for utility involvement with solar domestic hot water  

SciTech Connect

Solar water heating is one of a number of options that can be considered under utility demand-side management (DSM) programs. Utilities perceive a range of potential benefits for solar water heating in terms of customer service, energy conservation, load management, environmental enhancement, and public relations. The solar industry may benefit from utility marketing efforts, economies of scale, added credibility, financing options, and long-term maintenance arrangements. This paper covers three topics: (1) the energy and demand impacts of solar water heating on utility load profiles based on the results of four studies in the literature, (2) the results of workshops sponsored by the National Renewable Energy Laboratory (NREL) to identify key issues faced by utilities in considering residential solar water heating as a DSM option, (3) several current or planned utility programs to promote solar water heating. 7 refs.

Carlisle, N.; Christensen, C. [National Renewable Energy Lab., Golden, CO (United States); Barrett, L. [Barrett Consulting Associates, Inc., Colorado Springs, CO (United States)

1992-05-01T23:59:59.000Z

162

Hot water system is energized by exhaust gas  

Science Conference Proceedings (OSTI)

The combustion of hydrocarbon fuels (natural gas or oil) results in the formation of carbon dioxide and water (water vapor). This water vapor contains approximately 1000 Btu/lb. as latent heat and amounts to 10% of all the heat input to the boiler (combustion). This means that for an 80% efficient boiler operation, 50% of the heat wasted in the flue gas is latent heat - which can only be recovered by condensing the water vapor. Since the dew point of the flue gases is approximately 130/sup 0/F, it is necessary to cool the gases to ambient temperature for complete heat recovery. By reducing these gases to within 10/sup 0/ of the incoming cold water, this Eldon Corporation heat reclaimer can achieve temperatures as low as 45/sup 0/ in winter.

Not Available

1985-09-01T23:59:59.000Z

163

Performance of active solar domestic hot water heating systems. Comparative report, 1979-1980 season  

Science Conference Proceedings (OSTI)

The most recent composite results of analysis performed by Vitro Laboratories of solar hot water heating data for selected hot water sites in the National Solar Data Network (NSDN) are presented. Results presented have been developed on the basis of analysis of instrumented sites monitored through 1979-1980. A total of 45 sites in the National Solar Data Network (NSDN) were examined for this study. Eighteen of these were selected for in-depth treatment because of the availability of valid long term data. System descriptions, schematic diagrams and energy flow diagrams for these 18 sites are presented in Appendices A, B, and C, respectively. (WHK)

Cramer, M.A.; Kendall, P.W.; Rosenbusch, J.M.; Weinstein, R.A.

1980-01-01T23:59:59.000Z

164

Water Sampling At Mickey Hot Springs Area (Wood, 2002) | Open Energy  

Open Energy Info (EERE)

Mickey Hot Springs Area (Wood, Mickey Hot Springs Area (Wood, 2002) Exploration Activity Details Location Mickey Hot Springs Area Exploration Technique Water Sampling Activity Date Usefulness could be useful with more improvements DOE-funding Unknown Notes Geothermal fluids from hot springs and wells have been sampled from a number of locations, including: 1) the North Island of New Zealand (three sets of samples from three different years) and the South Island of New Zealand (1 set of samples); 2) the Cascades of Oregon; 3) the Harney, Alvord Desert and Owyhee geothermal areas of Oregon; 4) the Dixie Valley and Beowawe fields in Nevada; 5) Palinpiiion, the Philippines; 6) the Salton Sea and Heber geothermal fields of southern California; and 7) the Dieng field in Central Java, Indonesia. We have analyzed the samples from

165

Water Sampling At Umpqua Hot Springs Area (Wood, 2002) | Open Energy  

Open Energy Info (EERE)

Umpqua Hot Springs Area (Wood, Umpqua Hot Springs Area (Wood, 2002) Exploration Activity Details Location Umpqua Hot Springs Area Exploration Technique Water Sampling Activity Date Usefulness could be useful with more improvements DOE-funding Unknown Notes Geothermal fluids from hot springs and wells have been sampled from a number of locations, including: 1) the North Island of New Zealand (three sets of samples from three different years) and the South Island of New Zealand (1 set of samples); 2) the Cascades of Oregon; 3) the Harney, Alvord Desert and Owyhee geothermal areas of Oregon; 4) the Dixie Valley and Beowawe fields in Nevada; 5) Palinpiiion, the Philippines; 6) the Salton Sea and Heber geothermal fields of southern California; and 7) the Dieng field in Central Java, Indonesia. We have analyzed the samples from

166

Savings Project: Insulate Hot Water Pipes for Energy Savings...  

NLE Websites -- All DOE Office Websites (Extended Search)

the insulation done during new construction of a home, during other work on your water heater or pipes, or insulating the pipes yourself, is well worth the effort. In special...

167

CPS Energy - Solar Hot Water Rebate Program (Texas) | Open Energy...  

Open Energy Info (EERE)

Clean Energy Analysis Low Emission Development Strategies Oil & Gas Smart Grid Solar U.S. OpenLabs Utilities Water Wind Page Actions View form View source History View New...

168

Orange County - Solar Hot Water Rebate Program (Florida) | Open...  

Open Energy Info (EERE)

Clean Energy Analysis Low Emission Development Strategies Oil & Gas Smart Grid Solar U.S. OpenLabs Utilities Water Wind Page Actions View form View source History View New...

169

Measurements of the Electrical Conductivities of Air over Hot Water  

Science Conference Proceedings (OSTI)

Measurements of the conduction current between two electrodes in air over recently boiled water have been interpreted by Carlon as indicating that the humidified air became highly conductive and that large numbers of ions were produced in the air ...

C. B. Moore; B. Vonnegut

1988-03-01T23:59:59.000Z

170

Solar hot water pays off for commercial enterprises  

SciTech Connect

Two solar water heating systems in Florida are described. One system supplies a motel for guest rooms, laundry, and kitchen. The other system serves a coin-operated laundry. (WDM)

Jones, H.

1976-05-01T23:59:59.000Z

171

NV Energy (Southern Nevada)- Solar Hot Water Incentive Program  

Energy.gov (U.S. Department of Energy (DOE))

NV Energy is providing an incentive for its residential customers to install solar water heaters on their homes. As of May 1, 2012, NV Energy electric customers in Southern Nevada who own their...

172

Solar Hot Water Contractor Licensing (Arkansas) | Open Energy...  

Open Energy Info (EERE)

Low Emission Development Strategies Oil & Gas Smart Grid Solar U.S. OpenLabs Utilities Water Wind Page Actions View form View source History View New Pages Recent Changes All...

173

Commercial Solar Hot Water Financing Program | Open Energy Information  

Open Energy Info (EERE)

Low Emission Development Strategies Oil & Gas Smart Grid Solar U.S. OpenLabs Utilities Water Wind Page Actions View form View source History View New Pages Recent Changes All...

174

Water Sampling At Zim's Hot Springs Geothermal Area (Wood, 2002) | Open  

Open Energy Info (EERE)

2002) 2002) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Water Sampling At Zim's Hot Springs Geothermal Area (Wood, 2002) Exploration Activity Details Location Zim's Hot Springs Geothermal Area Exploration Technique Water Sampling Activity Date Usefulness could be useful with more improvements DOE-funding Unknown Notes Geothermal fluids from hot springs and wells have been sampled from a number of locations, including: 1) the North Island of New Zealand (three sets of samples from three different years) and the South Island of New Zealand (1 set of samples); 2) the Cascades of Oregon; 3) the Harney, Alvord Desert and Owyhee geothermal areas of Oregon; 4) the Dixie Valley and Beowawe fields in Nevada; 5) Palinpiiion, the Philippines; 6) the

175

Water Sampling At Breitenbush Hot Springs Area (Wood, 2002) | Open Energy  

Open Energy Info (EERE)

Wood, 2002) Wood, 2002) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Water Sampling At Breitenbush Hot Springs Area (Wood, 2002) Exploration Activity Details Location Breitenbush Hot Springs Area Exploration Technique Water Sampling Activity Date Usefulness could be useful with more improvements DOE-funding Unknown Notes Geothermal fluids from hot springs and wells have been sampled from a number of locations, including: 1) the North Island of New Zealand (three sets of samples from three different years) and the South Island of New Zealand (1 set of samples); 2) the Cascades of Oregon; 3) the Harney, Alvord Desert and Owyhee geothermal areas of Oregon; 4) the Dixie Valley and Beowawe fields in Nevada; 5) Palinpiiion, the Philippines; 6) the

176

Water Sampling At Belknap-Foley-Bigelow Hot Springs Area (Wood, 2002) |  

Open Energy Info (EERE)

Wood, 2002) Wood, 2002) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Water Sampling At Belknap-Foley-Bigelow Hot Springs Area (Wood, 2002) Exploration Activity Details Location Belknap-Foley-Bigelow Hot Springs Area Exploration Technique Water Sampling Activity Date Usefulness could be useful with more improvements DOE-funding Unknown Notes Geothermal fluids from hot springs and wells have been sampled from a number of locations, including: 1) the North Island of New Zealand (three sets of samples from three different years) and the South Island of New Zealand (1 set of samples); 2) the Cascades of Oregon; 3) the Harney, Alvord Desert and Owyhee geothermal areas of Oregon; 4) the Dixie Valley and Beowawe fields in Nevada; 5) Palinpiiion, the Philippines; 6) the

177

Hot water tank for use with a combination of solar energy and heat-pump desuperheating  

DOE Patents (OSTI)

A water heater or system is described which includes a hot water tank having disposed therein a movable baffle to function as a barrier between the incoming volume of cold water entering the tank and the volume of heated water entering the tank which is heated by the circulation of the cold water through a solar collector and/or a desuperheater of a heat pump so as to optimize the manner in which heat is imparted to the water in accordance to the demand on the water heater or system. A supplemental heater is also provided and it is connected so as to supplement the heating of the water in the event that the solar collector and/or desuperheater cannot impart all of the desired heat input into the water.

Andrews, J.W.

1980-06-25T23:59:59.000Z

178

Hot water tank for use with a combination of solar energy and heat-pump desuperheating  

DOE Patents (OSTI)

A water heater or system which includes a hot water tank having disposed therein a movable baffle to function as a barrier between the incoming volume of cold water entering the tank and the volume of heated water entering the tank which is heated by the circulation of the cold water through a solar collector and/or a desuperheater of a heat pump so as to optimize the manner in which heat is imparted to the water in accordance to the demand on the water heater or system. A supplemental heater is also provided and it is connected so as to supplement the heating of the water in the event that the solar collector and/or desuperheater cannot impart all of the desired heat input into the water.

Andrews, John W. (Sag Harbor, NY)

1983-06-28T23:59:59.000Z

179

NORTH PORTAL-HOT WATER CALCULATION-SHOP BUILDING #5006  

SciTech Connect

The purpose of this design analysis and calculation is to determine the demand for domestic cold water and to size the supply main for the Shop Building No.5006 in accordance with the Uniform Plumbing Code (UPC) (Section 4.4.1) and the U.S. Department of Energy, Order 6430.1A-1540 (Section 4.4.2).

R. Blackstone

2006-01-25T23:59:59.000Z

180

Natural radioactivity in geothermal waters, Alhambra Hot Springs and nearby areas, Jefferson County, Montana  

DOE Green Energy (OSTI)

Radioactive hot springs issue from a fault zone in crystalline rock of the Boulder batholith at Alhambra, Jefferson County, in southwestern Montana. The discharge contains high concentrations of radon, and the gross activity and the concentration of radium-226 exceed maximum levels recommended by the Environmental Protection Agency for drinking water. Part of the discharge is diverted for space heating, bathing, and domestic use. The radioactive thermal waters at measured temperatures of about 60/sup 0/C are of the sodium bicarbonate type and saturated with respect to calcium carbonate. Radium-226 in the rock and on fractured surfaces or coprecipitated with calcium carbonate probably is the principal source of radon that is dissolved in the thermal water and discharged with other gases from some wells and springs. Local surface water and shallow ground water are of the calcium bicarbonate type and exhibit low background radioactivity. The temperature, percent sodium, and radioactivity of mixed waters adjacent to the fault zone increase with depth. Samples from most of the major hot springs in southwestern Montana have been analyzed for gross alpha and beta. The high level of radioactivity at Alhambra appears to be related to leaching of radioactive material from fractured siliceous veins by ascending thermal waters, and is not a normal characteristic of hot springs issuing from fractured crystalline rock in Montana.

Leonard, R.B.; Janzer, W.J.

1977-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Performance of a Heat Pump Water Heater in the Hot-Humid Climate, Windermere, Florida (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Performance of a Performance of a Heat Pump Water Heater in the Hot-Humid Climate Windermere, Florida Over recent years, heat pump water heaters (HPWHs) have become more read- ily available and more widely adopted in the marketplace. A key feature of an HPWH unit is that it is a hybrid system. When conditions are favorable, the unit will operate in heat pump mode (using a vapor compression system that extracts heat from the surrounding air) to efficiently provide domestic hot water (DHW). Homeowners need not adjust their behavior to conform to the heat pump's capabilities. If a heat pump cannot meet a higher water draw demand, the heater will switch to electric resistance to provide a higher heating rate. This flexibility

182

INSTALLATION CERTIFICATE CF-6R-MECH-01 Domestic Hot Water (DHW) (Page 1 of 2)  

E-Print Network (OSTI)

: Heater Type CEC Certified Mfr Name & Model Number Distribution Type (Std, Point-of- Use, etc; and Pipe insulation for steam hydronic heating systems or hot water systems >15 psi, meets the requirements or fewer dwelling units which have (1) less than 25' of distribution piping outdoors; (2) zero distribution

183

LARGO hot water system long range thermal performance test report. Addendum  

DOE Green Energy (OSTI)

The test procedure used and the test results obtained during the long range thermal performance tests of the LARGO Solar Hot Water System under natural environmental conditions are presented. Objectives of these tests were to determine the amount of energy collected, the amount of power required for system operation, system efficiency temperature distribution and system performance degradation.

Not Available

1978-11-01T23:59:59.000Z

184

Improved Airborne Hot-Wire Measurements of Ice Water Content in Clouds  

Science Conference Proceedings (OSTI)

Airborne measurements of ice water content (IWC) in both ice and mixed phase clouds remain one of the long standing problems in experimental cloud physics. For nearly three decades, IWC has been measured with the help of the Nevzorov hot-wire ...

A. Korolev; J. W. Strapp; G. A. Isaac; E. Emery

185

Operation manual: solar hot water preheat, Henry's Lake State Park. Final technical report  

DOE Green Energy (OSTI)

Instructions for the assembling of the panel array and start-up procedures for the water heater are provided. The preheat system is designed for the months of May through September and provides 75% of hot water for an 800 gal/day use. The panels are disassembled and stored during the winter months. Information on troubleshooting the system, a set of as built plans and warranty material are included.

Not Available

1985-01-01T23:59:59.000Z

186

Don't Let Your Money and Hot Water Go Down the Drain | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Don't Let Your Money and Hot Water Go Down the Drain Don't Let Your Money and Hot Water Go Down the Drain Don't Let Your Money and Hot Water Go Down the Drain December 9, 2008 - 4:00am Addthis John Lippert Do you look at your retirement savings statements and feel like you're sending your money down the drain? Do you deposit more money each paycheck into your retirement account, but find the balance goes down, not up? Pssst, want to invest in a "sure thing?" No, this isn't a scam. It's a device that has no moving parts to break down, but is certain to save you energy, and thus save you money by lowering your utility bills. When we all take showers and baths, wash the dishes or clothes, and wash our hands, we send heated water literally down the drain. That typically represents 80%-90% of the energy used to heat water in a home. Drain-water (or

187

Active space heating and hot water supply with solar energy  

DOE Green Energy (OSTI)

Technical and economic assessments are given of solar water heaters, both circulating, and of air-based and liquid-based solar space heating systems. Both new and retrofit systems are considered. The technical status of flat-plate and evacuated tube collectors and of thermal storage is also covered. Non-technical factors are also briefly discussed, including the participants in the use of solar heat, incentives and deterrents. Policy implications are considered as regards acceleration of solar use, goals for solar use, means for achieving goals, and interaction of governments, suppliers, and users. Government actions are recommended. (LEW)

Karaki, S.; Loef, G. O.G.

1981-04-01T23:59:59.000Z

188

Low rank coal upgrading in a flow of hot water  

Science Conference Proceedings (OSTI)

Simultaneous hydrothermal degradation and extraction at around 350{sup o}C using flowing solvent as a reaction/extraction medium were proposed for upgrading brown coal, more specifically, for converting brown coal into several fractions having different molecular weight and chemical structure under mild conditions. When an Australian brown coal, Loy Yang coal, was treated by water at 350{sup o}C under 18 MPa, the coal was separated into four fractions: gaseous product by 8% yield, water-soluble extract at room temperature (soluble) by 23% yield, extract precipitates as solid at room temperature (deposit) by 23% yield, and residual coal (upgraded coal) by 46% yield on daf basis. The separation was found to be realized by in situ extraction of low-molecular-weight substances released from coal macromolecular structure and/or those generated by hydrothermal decomposition reactions at 350{sup o}C. The solid products obtained, deposit and upgraded coal, were characterized in detail to examine the possibility of their effective utilization as solid fuel and chemical feed stock. The upgraded coal showed higher heating value and higher gasification reactivity than the parent coal, indicating that the upgraded coal can be a better solid fuel than the parent coal. The solid extract, deposit, was found to show thermoplasticity at less than 200{sup o}C, suggesting the possibility of utilizing the deposit as a raw material of high performance carbon materials. Several variables affecting the performance of the proposed method are also examined in detail in this paper. 12 refs., 8 figs., 3 tabs.

Masato Morimoto; Hiroyuki Nakagawa; Kouichi Miura [Kyoto University, Kyoto (Japan). Department of Chemical Engineering

2009-09-15T23:59:59.000Z

189

Promising freeze protection alternatives in solar domestic hot water systems  

DOE Green Energy (OSTI)

Since the gains associated with solar thermal energy technologies are comparatively small in relation to the required capital investment, it is vital to maximize conversion efficiency. While providing the necessary function of freeze protection, the heat exchanger commonly included in solar domestic water heating systems represents a system inefficiency. This thesis explores two alternate methods of providing freeze protection without resorting to a heat exchanger. Commonly, collectors are made of rigid copper tubes separated by copper or aluminum fins. Cracking damage can occur when water is allowed to freeze and expand inside the non compliant tubes. The possibility of making collectors out of an elastic material was investigated and shown to be effective. Since unlike copper, elastomers typically have low thermal conductivities, the standard collector performance prediction equations do not apply. Modified thermal performance prediction equations were developed which can be used for both low and high thermal conductivity materials to provide accurate predictions within a limited range of plate geometries. An elastomeric collector plate was then designed and shown to have comparable performance to a copper plate collector whose aperture area is approximately 33% smaller. Another options for providing freeze protection to an SDHW system is to turn it off during the winter. Choosing a three-season operating period means two things. First, the system will have different optimums such as slope and collector area. Second, the wintertime solar energy incident on the collector is unavailable for meeting a heating load. However, the system`s heat exchanger becomes unnecessary and removing it increases the amount of energy that arrives at the storage tank during those periods in which the system is operating.

Bradley, D.E.

1997-12-31T23:59:59.000Z

190

Measure Guideline: Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems  

SciTech Connect

This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heating equipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

Rudd, A.

2012-08-01T23:59:59.000Z

191

Polyethylene fiber drawing optimization  

E-Print Network (OSTI)

Polymer fiber drawing creates fibers with enhanced thermal conductivity and strength compared to bulk polymer because drawing aligns the molecular chains. I optimize the polymer fiber drawing method in order to achieve ...

Chiloyan, Vazrik

2011-01-01T23:59:59.000Z

192

Solar hot water demonstration project at Red Star Industrial Laundry, Fresno, California  

SciTech Connect

The Final Report of the Solar Hot Water System located at the Red Star Industrial Laundry, 3333 Sabre Avenue, Fresno, California, is presented. The system was designed as an integrated wastewater heat recovery and solar preheating system to supply a part of the hot water requirements. It was estimated that the natural gas demand for hot water heating could be reduced by 56 percent (44 percent heat reclamation and 12 percent solar). The system consists of a 16,500 gallon tube-and-shell wastewater heat recovery subsystem combined with a pass-through 6,528 square foot flat plate Ying Manufacturing Company Model SP4120 solar collector subsystem, a 12,500 gallon fiber glass water storage tank subsystem, pumps, heat exchangers, controls, and associated plumbing. The design output of the solar subsystem is approximately 2.6 x 10/sup 9/ Btu/year. Auxiliary energy is provided by a gas fired low pressure boiler servicing a 4,000 gallon service tank. This project is part of the US Department of Energy's Solar Demonstration Program with DOE sharing $184,841 of the $260,693 construction cost. The system was turned on in July 1977, and acceptance tests completed in September 1977. The demonstration period for this project ends September 2, 1982.

1980-07-01T23:59:59.000Z

193

Cost effective solar hot water system for econo-travel motor hotel located at Hampton, VA  

SciTech Connect

This paper gives the final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 2708 Mercury Boulevard, Hampton, Virginia. The description of the system along with the final cost breakdown, performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

1978-11-01T23:59:59.000Z

194

Cost effective solar hot water system for Econo-Travel Motor Hotel, Chesapeake, Virginia. Final report  

SciTech Connect

The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 4725 W. Military Highway, Chesapeake, Virginia, is presented. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

1978-12-01T23:59:59.000Z

195

Cost effective solar hot water system for econo-travel motor hotel located at Hampton, VA  

DOE Green Energy (OSTI)

This paper gives the final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 2708 Mercury Boulevard, Hampton, Virginia. The description of the system along with the final cost breakdown, performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

Not Available

1978-11-01T23:59:59.000Z

196

Cost effective solar hot water system for Econo-Travel Motor Hotel, Chesapeake, Virginia. Final report  

DOE Green Energy (OSTI)

The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 4725 W. Military Highway, Chesapeake, Virginia, is presented. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

Not Available

1978-12-01T23:59:59.000Z

197

Surface water supply for the Clearlake, California Hot Dry Rock Geothermal Project  

DOE Green Energy (OSTI)

It is proposed to construct a demonstration Hot Dry Rock (HDR) geothermal plant in the vicinity of the City of Clearlake. An interim evaluation has been made of the availability of surface water to supply the plant. The evaluation has required consideration of the likely water consumption of such a plant. It has also required consideration of population, land, and water uses in the drainage basins adjacent to Clear Lake, where the HDR demonstration project is likely to be located. Five sources were identified that appear to be able to supply water of suitable quality in adequate quantity for initial filling of the reservoir, and on a continuing basis, as makeup for water losses during operation. Those sources are California Cities Water Company, a municipal supplier to the City of Clearlake; Clear Lake, controlled by Yolo County Flood Control and Water Conservation District; Borax Lake, controlled by a local developer; Southeast Regional Wastewater Treatment Plant, controlled by Lake County; and wells, ponds, and streams on private land. The evaluation involved the water uses, water rights, stream flows, precipitation, evaporation, a water balance, and water quality. In spite of California`s prolonged drought, the interim conclusion is that adequate water is available at a reasonable cost to supply the proposed HDR demonstration project.

Jager, A.R.

1996-03-01T23:59:59.000Z

198

Design and Experiments of a Solar Low-temperature Hot Water Floor Radiant Heating System  

E-Print Network (OSTI)

The solar low-temperature hot water floor radiant heating system combines solar energy heating with floor radiant heating. This kind of environmental heating way not only saves fossil resources and reduces pollution, but also makes people feel more comfortable. First, the authors devised an experimental scheme and set up the laboratory. Second, we collected a great deal of data on the system in different situations. Finally, we conclude that such heating system is feasible and one of the best heating methods.

Wu, Z.; Li, D.

2006-01-01T23:59:59.000Z

199

Consumer thermal energy storage costs for residential hot water, space heating and space cooling systems  

DOE Green Energy (OSTI)

The cost of household thermal energy storage (TES) in four utility service areas that are representative for hot water, space heating, and space cooling systems in the United States is presented. There are two major sections of the report: Section 2.0 is a technology characterization of commercially available and developmental/conceptual TES systems; Section 3.0 is an evaluation of the consumer cost of the three TES systems based on typical designs in four utility service areas.

None

1976-11-30T23:59:59.000Z

200

Solar production of industrial process hot water: operation and evaluation of the Campbell Soup hot water solar facility. Final report, September 1, 1979-December 10, 1980  

DOE Green Energy (OSTI)

The operation and evaluation of a solar hot water facility designed by Acurex Corporation and installed (November 1977) at the Campbell Soup Company Sacramento, California canning plant is summarized. The period of evaluation was for 12 months from October 1979 through September 1980. The objective of the work was to obtain additional, long term data on the operation and performance of the facility. Minor modifications to the facility were completed. The system was operated for 15 months, and 12 months of detailed data were evaluated. The facility was available for operation 99% of the time during the last 8 months of evaluation. A detailed description of the solar facility and of the operating experience is given, and a summary of system performance for the 12 month operation/evaluation period is presented. Recommendations for large-scale solar facilities based on this project's experience are given, and an environmental impact assessment for the Campbell Soup solar facility is provided. (WHK)

Kull, J. I.; Niemeyer, W. N.; Youngblood, S. B.

1980-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Multielement geochemistry of solid materials in geothermal systems and its applications. Part 1. Hot-water system at the Roosevelt Hot Springs KGRA, Utah  

DOE Green Energy (OSTI)

Geochemical studies of the geothermal system at Roosevelt Hot Springs, Utah, have led to development of chemical criteria for recognition of major features of the system and to a three-dimensional model for chemical zoning in the system. Based on this improved level of understanding several new or modified geochemical exploration and assessment techniques have been defined and are probably broadly applicable to evaluation of hot-water geothermal systems. The main purpose of this work was the development or adaptation of solids geochemical exploration techniques for use in the geothermal environment. (MHR)

Bamford, R.W.; Christensen, O.D.; Capuano, R.M.

1980-02-01T23:59:59.000Z

202

Application of solar energy to the supply of hot water for textile dyeing. Final report, CDRL/PA 10  

DOE Green Energy (OSTI)

The design plan for a solar process hot water system for a textile dye beck at Riegel Textile Corporation's LaFrance, South Carolina, facilities is presented. The solar system consists of 396 GE model TC 100 evacuated tube collector modules arranged in a ground mounted array with a total collector area of 6680 square feet. The system includes an 8000-gallon hot water storage tank. Systems analyses, specification sheets, performance data, and an economic evaluation of the proposed system are presented. (WHK)

None

1977-09-01T23:59:59.000Z

203

Estimating Energy and Water Losses in Residential Hot Water Distribution Systems  

E-Print Network (OSTI)

by showers, faucets, and dishwashers. (Actual leaks of hotdraws for sinks and dishwashers may not waste water, from anheat the water. For dishwashers, not only is energy wasted

Lutz, James

2005-01-01T23:59:59.000Z

204

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network (OSTI)

heater analysis model (WHAM) and a hot water draw model,heaters is calculated using WHAM, which accounts for a rangeTo account for this factor, WHAM is expanded to include the

Franco, Victor

2011-01-01T23:59:59.000Z

205

DOE Office of Indian Energy Foundational Course on Direct Use for Building Heat and Hot Water  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DIRECT USE FOR BUILDING HEAT & HOT WATER Presented by the National Renewable Energy Laboratory Course Outline 2 What we will cover...  About the DOE Office of Indian Energy Education Initiative  Course Introduction  Solar Thermal and Solar Ventilation Air Pre-Heat - Resources, Technology, Examples & Cost, and References  Biomass Heat - Resources, Technology, Examples & Cost, and References  Geothermal Building Heat - Resources, Technology, Examples & Cost, and References  Additional Information & Resources Introduction The U.S. Department of Energy (DOE) Office of Indian Energy Policy and Programs is responsible for assisting Tribes with energy planning and development, infrastructure, energy costs, and electrification of Indian

206

Applications of Commercial Heat Pump Water Heaters in Hot, Humid Climates  

E-Print Network (OSTI)

Heat pump water heaters can provide high-efficiency water heating and supplemental space cooling and dehumidification in commercial buildings throughout the United States. They are particularly attractive in hot, humid areas where cooling loads are high and the cooling season is long. Because commercial kitchens and laundry facilities have simultaneous water heating and cooling needs, they are excellent applications for heat pump water heaters. Typical heat pump water heaters (HPWHs) operate at an annual coefficient of performance (COP) of approximately 3.0 for water heating alone. Space conditioning benefits of about 0.67 Btu are delivered at no additional cost for each Btu of water heating output. In situations in which this cooling output is valued, the dual thermal outputs for heating and cooling make heat pump water heaters particularly attractive. The comfort value of added cooling in overheated facilities and the resulting increase in employee and customer satisfaction are frequently cited as additional benefits. This paper describes currently available heat pump water heating equipment and offers guidelines for successful applications in commercial facilities. The results of field test programs involving more than 100 units in Alabama, Georgia, Mississippi, Tennessee, South Carolina, and other areas are incorporated. Initial conclusions are drawn from a reliability database, and interviews with utility applications specialists and manufacturers are discussed. Design tools are reviewed, including a new comprehensive computer simulation model. Emphasis is placed on identifying sound candidates for installations and on application and design considerations. A brief survey is provided of environmental implications of heat pump water heaters and new developments in heat pump water heater equipment.

Johnson, K. F.; Shedd, A. C.

1992-05-01T23:59:59.000Z

207

Drawing phylogenetic trees  

Science Conference Proceedings (OSTI)

We present linear-time algorithms for drawing phylogenetic trees in radial and circular representations. In radial drawings given edge lengths (representing evolutionary distances) are preserved, but labels (names of taxons represented in the leaves) ...

Christian Bachmaier; Ulrik Brandes; Barbara Schlieper

2005-12-01T23:59:59.000Z

208

Measured electric hot water standby and demand loads from Pacific Northwest homes. End-Use Load and Consumer Assessment Program  

SciTech Connect

The Bonneville Power Administration began the End-Use Load and Consumer Assessment Program (ELCAP) in 1983 to obtain metered hourly end-use consumption data for a large sample of new and existing residential and commercial buildings in the Pacific Northwest. Loads and load shapes from the first 3 years of data fro each of several ELCAP residential studies representing various segments of the housing population have been summarized by Pratt et al. The analysis reported here uses the ELCAP data to investigate in much greater detail the relationship of key occupant and tank characteristics to the consumption of electricity for water heating. The hourly data collected provides opportunities to understand electricity consumption for heating water and to examine assumptions about water heating that are critical to load forecasting and conservation resource assessments. Specific objectives of this analysis are to: (A) determine the current baseline for standby heat losses by determining the standby heat loss of each hot water tank in the sample, (B) examine key assumptions affecting standby heat losses such as hot water temperatures and tank sizes and locations, (C) estimate, where possible, impacts on standby heat losses by conservation measures such as insulating tank wraps, pipe wraps, anticonvection valves or traps, and insulating bottom boards, (D) estimate the EF-factors used by the federal efficiency standards and the nominal R-values of the tanks in the sample, (E) develop estimates of demand for hot water for each home in the sample by subtracting the standby load from the total hot water load, (F) examine the relationship between the ages and number of occupants and the hot water demand, (G) place the standby and demand components of water heating electricity consumption in perspective with the total hot water load and load shape.

Pratt, R.G.; Ross, B.A.

1991-11-01T23:59:59.000Z

209

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

E-Print Network (OSTI)

Study on Eco-Design of Water Heaters, Van Holstein en Kemnaand Assessment in Water Heating Rulemaking TechnicalG. Smith, Tankless Gas Water Heaters: Oregon Market Status,

Lu, Alison

2011-01-01T23:59:59.000Z

210

High performance in low-flow solar domestic hot water systems  

DOE Green Energy (OSTI)

Low-flow solar hot water heating systems employ flow rates on the order of 1/5 to 1/10 of the conventional flow. Low-flow systems are of interest because the reduced flow rate allows smaller diameter tubing, which is less costly to install. Further, low-flow systems result in increased tank stratification. Lower collector inlet temperatures are achieved through stratification and the useful energy produced by the collector is increased. The disadvantage of low-flow systems is the collector heat removal factor decreases with decreasing flow rate. Many solar domestic hot water systems require an auxiliary electric source to operate a pump in order to circulate fluid through the solar collector. A photovoltaic driven pump can be used to replace the standard electrical pump. PV driven pumps provide an ideal means of controlling the flow rate, as pumps will only circulate fluid when there is sufficient radiation. Peak performance was always found to occur when the heat exchanger tank-side flow rate was approximately equal to the average load flow rate. For low collector-side flow rates, a small deviation from the optimum flow rate will dramatically effect system performance.

Dayan, M.

1997-12-31T23:59:59.000Z

211

Evaluation of economics of hotel/motel solar hot water projects  

SciTech Connect

Experience gained by the Ames Laboratory in managing projects in the Solar Hotel/Motel Hot Water initiative is used to evaluate economic factors. The analysis studies costs and trends from a limited number of projects. Initial analysis, based on cost data presented in the project proposals, shows that cost estimates vary widely for various reasons. Further analysis, based on incurred costs as projects are completed, is a continuing process. These actual costs are normalized to the extent possible to provide consistent comparisons between the systems of various projects. Correlations between proposed costs and actual costs are made to assist future evaluation of similar projects. Several projects, which were offered a grant to participate in these Hotel/Motel demonstrations, have declined to accept the grant on economic grounds. Economic analysis of these projects provides rationale for the apparent cost ineffectiveness. Systems now in operation have provided fuel cost savings data which are presented to show system payback periods. Finally, results of economic analysis of these projects are presented together with initial conclusions regarding cost-effective solar hot water system design.

Struss, R.G.; Brohl, E.C.; Sidles, P.H.

1978-01-01T23:59:59.000Z

212

Residential Ground Source Heat Pumps with Integrated Domestic Hot Water Generation: Performance Results from Long-Term Monitoring  

SciTech Connect

Ground source heat pumps (GSHPs) show promise for reducing house energy consumption, and a desuperheater can potentially further reduce energy consumption where the heat pump from the space conditioning system creates hot water. Two unoccupied houses were instrumented to document the installed operational space conditioning and water heating efficiency of their GSHP systems. This paper discusses instrumentation methods and field operation characteristics of the GSHPs, compares manufacturers' values of the coefficients of performance calculated from field measured data for the two GSHPs, and compares the measured efficiency of the desuperheater system to other domestic hot water systems.

Stecher, D.; Allison, K.

2012-11-01T23:59:59.000Z

213

Cold-Climate Solar Domestic Hot Water Systems: Cost/Benefit Analysis and Opportunities for Improvement  

DOE Green Energy (OSTI)

To determine potential for reduction in the cost of saved energy (COSE) for cold-climate solar domestic hot water (SDHW) systems, COSE was computed for three types of cold climate water heating systems. For each system, a series of cost-saving measures was considered: (1) balance of systems (BOS): tank, heat exchanger, and piping-valving measures; and (2) four alternative lower-cost collectors. Given all beneficial BOS measures in place, >50% reduction of COSE was achievable only with selective polymer collectors at half today's selective collector cost. In all three system types, today's metal-glass selective collector achieved the same COSE as the hypothesized non-selective polymer collector.

Burch, J.; Hillman, T.; Salasovich, J.

2005-01-01T23:59:59.000Z

214

LWRS Fuels Pathway: Engineering Design and Fuels Pathway Initial Testing of the Hot Water Corrosion System  

Science Conference Proceedings (OSTI)

The Advanced LWR Nuclear Fuel Development R&D pathway performs strategic research focused on cladding designs leading to improved reactor core economics and safety margins. The research performed is to demonstrate the nuclear fuel technology advancements while satisfying safety and regulatory limits. These goals are met through rigorous testing and analysis. The nuclear fuel technology developed will assist in moving existing nuclear fuel technology to an improved level that would not be practical by industry acting independently. Strategic mission goals are to improve the scientific knowledge basis for understanding and predicting fundamental nuclear fuel and cladding performance in nuclear power plants, and to apply this information in the development of high-performance, high burn-up fuels. These will result in improved safety, cladding, integrity, and nuclear fuel cycle economics. To achieve these goals various methods for non-irradiated characterization testing of advanced cladding systems are needed. One such new test system is the Hot Water Corrosion System (HWCS) designed to develop new data for cladding performance assessment and material behavior under simulated off-normal reactor conditions. The HWCS is capable of exposing prototype rodlets to heated, high velocity water at elevated pressure for long periods of time (days, weeks, months). Water chemistry (dissolved oxygen, conductivity and pH) is continuously monitored. In addition, internal rodlet heaters inserted into cladding tubes are used to evaluate repeated thermal stressing and heat transfer characteristics of the prototype rodlets. In summary, the HWCS provides rapid ex-reactor evaluation of cladding designs in normal (flowing hot water) and off-normal (induced cladding stress), enabling engineering and manufacturing improvements to cladding designs before initiation of the more expensive and time consuming in-reactor irradiation testing.

Dr. John Garnier; Dr. Kevin McHugh

2012-09-01T23:59:59.000Z

215

U.S. Marine Corps Base Camp Pendleton: Using The Sun For Hot Water And Electricity, Federal Energy Management Program (FEMP) (Fact Sheet)  

DOE Green Energy (OSTI)

Case study overview of integrated solar hot water/photovoltaic systems at the U.S. Marine Corps Camp Pendleton training pools.

Not Available

2009-09-01T23:59:59.000Z

216

Proposal for the Purchase, Without a Call for Tenders, of a Medium-Temperature Hot Water Boiler for the 300 GeV Accelerator  

E-Print Network (OSTI)

Proposal for the Purchase, Without a Call for Tenders, of a Medium-Temperature Hot Water Boiler for the 300 GeV Accelerator

1976-01-01T23:59:59.000Z

217

American Recovery and Reinvestment Act (ARRA) Federal Energy Management Program Technical Assistance Project 281 Solar Hot Water Application Assessment for U.S. Army IMCOM-Southeast Region  

SciTech Connect

The Energy Independence and Security Act of 2007 requires installations (EISA) to install solar systems of sufficient capacity to provide 30% of service hot water in new construction and renovations where cost-effective. However, installations are struggling with how to implement solar hot water, and while several installations are installing solar hot water on a limited basis, paybacks remain long. Pacific Northwest National Laboratory (PNNL) was tasked to address this issue to help determine how best to implement solar hot water projects. This documents discusses the results of that project.

Russo, Bryan J.; Chvala, William D.

2010-09-30T23:59:59.000Z

218

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

E-Print Network (OSTI)

heater storage tank wastes energy to continuous heating.fired water heater Total Energy Total Waste Emissions (Air)fired water heater Total Energy Total Waste Emissions (Air)

Lu, Alison

2011-01-01T23:59:59.000Z

219

Integrated solar heating, cooling and hot water system for the San Diego City Schools, University City High School (Engineering Materials)  

DOE Green Energy (OSTI)

The solar system consists of a heating circuit, two 200-ton absorption chiller hot water circuits and a hot water tube bundle circuit combined with solar collection and storage loops into a single integrated thermal system. Gas fired boilers provide backup and load peaking. Solar collection is provided by three types of panels located on a south facing hill from top to bottom are as follows: parabolic tracking concentrating reflectors, 7680 ft/sup 2/; parabolic fixed concentrating reflectors, 7364 ft/sup 2/; and fresnel lens concentrating, tracking, 2488 ft/sup 2/. The storage capacity is 88,800 gallons in 3 steel tanks. Reference DOE/CS/31499-T2.

Not Available

220

An investigation of photovoltaic powered pumps in direct solar domestic hot water systems  

DOE Green Energy (OSTI)

The performance of photovoltaic powered pumps in direct solar domestic hot water (PV-SDHW) systems has been studied. The direct PV- SDHW system employs a photovoltaic array, a separately excited DC- motor, a centrifugal pump, a thermal collector, and a storage tank. A search methodology for an optimum PV-SDHW system configuration has been proposed. A comparison is made between the long-term performance of a PV-SDHW system and a conventional SDHW system operating under three control schemes. The three schemes are: an ON-OFF flow controlled SDHW system operating at the manufacturer-recommended constant flow rate, and a linear proportional flow controlled SDHW system with the flow proportional to the solar radiation operating under an optimum proportionality. 13 refs., 6 figs.

Al-Ibrahim, A.M.; Klein, S.A.; Mitchell, J.W.; Beckman, W.A.

1996-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Analysis of space heating and domestic hot water systems for energy-efficient residential buildings  

DOE Green Energy (OSTI)

An analysis of the best ways of meeting the space heating and domestic hot water (DHW) needs of new energy-efficient houses with very low requirements for space heat is provided. The DHW load is about equal to the space heating load in such houses in northern climates. The equipment options which should be considered are discussed, including new equipment recently introduced in the market. It is concluded that the first consideration in selecting systems for energy-efficient houses should be identification of the air moving needs of the house for heat distribution, heat storage, ventilation, and ventilative cooling. This is followed, in order, by selection of the most appropriate distribution system, the heating appliances and controls, and the preferred energy source, gas, oil, or electricity.

Dennehy, G

1983-04-01T23:59:59.000Z

222

Solar heating and hot water system for the central administrative office facility. Technical progress report  

DOE Green Energy (OSTI)

Progress on the solar heating and hot water system for the central administrative office facility of the Lincoln Housing Authority, Lincoln, NE is covered. An acceptance test plan is presented and the results of the test are tabulated. A complete blueprint of the system as built is provided. The monitoring system is drawn and settings and installation are described. An operation and maintenance manual discusses procedures for start up, shut down and seasonal changeover and include a valve list and pictures and specifications of components and materials used. Photographs of the final installation are included, and technical data and performance data are given. Finally, there is a brief description of system design and operation and a discussion of major maintenance problems encountered and their solutions. (LEW)

Not Available

1978-11-01T23:59:59.000Z

223

Assembly and comparison of available solar hot water system reliability databases and information.  

DOE Green Energy (OSTI)

Solar hot water (SHW) systems have been installed commercially for over 30 years, yet few quantitative details are known about their reliability. This report describes a comprehensive analysis of all of the known major previous research and data regarding the reliability of SHW systems and components. Some important conclusions emerged. First, based on a detailed inspection of ten-year-old systems in Florida, about half of active systems can be expected to fail within a ten-year period. Second, valves were identified as the probable cause of a majority of active SHW failures. Third, passive integral and thermosiphon SHW systems have much lower failure rates than active ones, probably due to their simple design that employs few mechanical parts. Fourth, it is probable that the existing data about reliability do not reveal the full extent of fielded system failures because most of the data were based on trouble calls. Often an SHW system owner is not aware of a failure because the backup system silently continues to produce hot water. Thus, a repair event may not be generated in a timely manner, if at all. This final report for the project provides all of the pertinent details about this study, including the source of the data, the techniques to assure their quality before analysis, the organization of the data into perhaps the most comprehensive reliability database in existence, a detailed statistical analysis, and a list of recommendations for additional critical work. Important recommendations include the inclusion of an alarm on SHW systems to identify a failed system, the need for a scientifically designed study to collect high-quality reliability data that will lead to design improvements and lower costs, and accelerated testing of components that are identified as highly problematic.

Menicucci, David F. (Building Specialists, Inc., Albuquerque, NM)

2009-05-01T23:59:59.000Z

224

Feasibility Study for Photovoltaics, Wind, solar Hot Water and Hybrid Systems  

DOE Green Energy (OSTI)

Southwestern Indian Polytechnic Institute (SIPI) located in Albuquerque New Mexico is a community college that serves American Indians and Alaska Natives. SIPIs student body represents over 100 Native American Tribes. SIPI completed a renewable energy feasibility study program and established renewable energy hardware on the SIPI campus, which supplements and creates an educational resource to teach renewable energy courses. The SIPI campus is located, and has as student origins, areas, in which power is an issue in remote reservations. The following hardware was installed and integrated into the campus facilities: small wind turbine, large photovoltaic array that is grid-connected, two photovoltaic arrays, one thin film type, and one polycrystalline type, one dual-axis active tracker and one passive tracker, a hot air system for heating a small building, a portable hybrid photovoltaic system for remote power, and a hot water system to preheat water used in the SIPI Child Care facility. Educational curriculum has been developed for two renewable energy courses one being the study of energy production and use, and especially the roles renewable energy forms like solar, wind, geothermal, hydro, and biomass plays, and the second course being a more advanced in-depth study of renewable energy system design, maintenance, installation, and applications. Both courses rely heavily on experiential learning techniques so that installed renewable energy hardware is continuously utilized in hand-on laboratory activities and are part of the Electronics program of studies. Renewable energy technologies and science has also been included in other SIPI programs of study such as Environmental Science, Natural Resources, Agriculture, Engineering, Network Management, and Geospatial Technology.

Hooks, Ronald; Montoya, Valerie

2008-03-26T23:59:59.000Z

225

Applicability of Related Data, Algorithms, and Models to the Simulation of Ground-Coupled Residential Hot Water Piping in California  

SciTech Connect

Residential water heating is an important consideration in California?s building energy efficiency standard. Explicit treatment of ground-coupled hot water piping is one of several planned improvements to the standard. The properties of water, piping, insulation, backfill materials, concrete slabs, and soil, their interactions, and their variations with temperature and over time are important considerations in the required supporting analysis. Heat transfer algorithms and models devised for generalized, hot water distribution system, ground-source heat pump and ground heat exchanger, nuclear waste repository, buried oil pipeline, and underground electricity transmission cable applications can be adapted to the simulation of under-slab water piping. A numerical model that permits detailed examination of and broad variations in many inputs while employing a technique to conserve computer run time is recommended.

Warner, J.L.; Lutz, J.D.

2006-01-01T23:59:59.000Z

226

Application of solar energy to the supply of industrial process hot water. Aerotherm final report, 77-235. [Can washing in Campbell Soup plant  

DOE Green Energy (OSTI)

The objectives of the Solar Industrial Process Hot Water Program are to design, test, and evaluate the application of solar energy to the generation and supply of industrial process hot water, and to provide an assessment of the economic and resource benefits to be gained. Other objectives are to stimulate and give impetus to the use of solar energy for supplying significant amounts of industrial process heat requirements. The plant selected for the design of a solar industrial process hot water system was the Campbell Soup facility in Sacramento, California. The total hot water demand for this plant varies between 500 and 800 gpm during regular production shifts, and hits a peak of over 1,000 gpm for approximately one hour during the cleanup shift. Most of the hot water is heated in the boiler room by a combination of waste heat recovery and low pressure (5 psi) steam-water heat exchangers. The hot water emerges from the boiler room at a temperature between 160/sup 0/F and 180/sup 0/F and is transported to the various process areas. Booster heaters in the process areas then use low pressure (5 psi) or medium pressure (20 psi) steam to raise the temperature of the water to the level required for each process. Hot water is used in several processes at the Campbell Soup plant, but the can washing process was selected to demonstrate the feasibility of a solar hot water system. A detailed design and economic analysis of the system is given. (WHK)

None

1977-01-01T23:59:59.000Z

227

Drawing in the lamposcope  

Science Conference Proceedings (OSTI)

The Lamposcope is a low-cost mixed reality system that enables a shared experience of art or design communication and collaboration mediated by light. Two participants in different places share a single drawing, to which they can contribute using familiar ... Keywords: CSCW, art, collaboration, drawing, lamposcope, media space, mixed reality, natural materials, physical computing, place, remote collaboration, sketching

Viveka Weiley; Matt Adcock

2013-06-01T23:59:59.000Z

228

Solar heating, cooling, and hot water systems installed at Richland, Washington. Final report  

DOE Green Energy (OSTI)

Project Sunburst is a demonstration system for solar space heating and cooling and solar hot water heating for a 14,400 square foot office building in Richland, Washington. The project is part of the US Department of Energy's solar demonstration program, and became operational in April 1978. The solar system uses 6,000 square feet of flat-plate liquid collectors in a closed loop to deliver solar energy through a liquid--liquid heat exchanger to the building heat-pump duct work or 9,000-gallon thermal energy storage tank. A 25-ton Arkla solar-driven absorption chiller provides the cooling, in conjunction with a 2,000 gallon chilled water storage tank and reflective ponds on three sides of the building to reject surplus heat. A near-by building is essentially identical except for having conventional heat-pump heating and cooling, and can serve as an experimental control. An on-going public relations program has been provided from the beginning of the program and has resulted in numerous visitors and tour groups.

Not Available

1979-06-01T23:59:59.000Z

229

Drawing the electric  

E-Print Network (OSTI)

This thesis explores the intersection of craft and electronics by way of paper and conductive ink, a domain that I'm terming papercraft electronics-a synthesis of electronics, drawing, and painting. I investigate the nature ...

Jacoby, Samuel (Samuel David Glauberman)

2013-01-01T23:59:59.000Z

230

Tank farms essential drawing plan  

SciTech Connect

The purpose of this document is to define criteria for selecting Essential Drawings, Support Drawings, and Controlled Print File (CPF) drawings and documents for facilities that are part of East and West Tank Farms. Also, the drawings and documents that meet the criteria are compiled separate listings. The Essential Drawing list and the Support Drawing list establish a priority for updating technical baseline drawings. The CPF drawings, denoted by an asterisk (*), defined the drawings and documents that Operations is required to maintain per the TWRS Administration Manual. The Routing Boards in Buildings 272-WA and 272-AW are not part of the CPF.

Domnoske-Rauch, L.A.

1998-08-04T23:59:59.000Z

231

New and retrofit solar hot water installations in Florida, January--June 1977  

SciTech Connect

The purpose of this project was to ascertain the number of solar hot water installations in new buildings versus the number retrofitted to existing buildings in Florida during the January to June period of 1977. The methodology was to survey all installations started, in progress, or completed during that period. A by-product of the survey is a comprehensive list of manufacturers and another of distributors and installers in Florida. The survey excludes space heating and cooling and pool heating applications. However, the latter is being considered for a separate survey. Installations included are in the single-family and multi-family residential, commercial, industrial and public sectors. In the single-family residential sector, care has been taken to determine a new or retrofit breakdown, average square footage of collector per installation, average cost per square foot of collector in Florida, and subsequently, using F-CHART and system sizing programs developed at the Center, the fraction of load supplied by solar and its equivalent barrels of oil saved per year. In the multi-family residential, commercial, industrial and public sectors, specific information on each installation has been provided. This information includes new or retrofit, ownership, type of collector and manufacturer, square footage of installation, design percentage energy by solar, suxiliary fuel, system cost, and federal grants, if any.

1978-04-01T23:59:59.000Z

232

Low-Cost Solar Domestic Hot Water Systems for Mild Climates  

DOE Green Energy (OSTI)

In FY99, Solar Heating and Lighting set the goal to reduce the life-cycle cost of saved-energy for solar domestic hot water (SDHW) systems in mild climates by 50%, primarily through use of polymer technology. Two industry teams (Davis Energy Group/SunEarth (DEG/SE) and FAFCO) have been developing un-pressurized integral-collector-storage (ICS) systems having load-side heat exchangers, and began field-testing in FY04. DEG/SE?s ICS has a rotomolded tank and thermoformed glazing. Based upon manufacturing issues, costs, and poor performance, the FAFCO team changed direction in late FY04 from an un-pressurized ICS to a direct thermosiphon design based upon use of pool collectors. Support for the teams is being provided for materials testing, modeling, and system testing. New ICS system models have been produced to model the new systems. A new ICS rating procedure for the ICS systems is undergoing testing and validation. Pipe freezing, freeze protection valves, and overheating have been tested and analyzed.

Burch, J.; Christensen, C.; Merrigan, T.; Hewett, R.; Jorgensen, G.

2005-01-01T23:59:59.000Z

233

Annual fuel usage charts for oil-fired boilers. [Building space heating and hot water supplies  

SciTech Connect

On the basis of laboratory-determined boiler efficiency data, one may calculate the annual fuel usage (AFU) for any oil-fired boiler, serving a structure of a given design heat load, for any specified hourly weather pattern. Further, where data are available regarding the energy recapture rates of the strucutre due to direct gain solar energy (windows), lighting, cooking, electrical appliances, metabolic processes, etc., the annual fuel usage savings due to such (re) capture are straightforwardly determinable. Employing the Brookhaven National Laboratory annual fuel usage formulation, along with efficiency data determined in the BNL Boiler Laboratory, computer-drawn annual fuel usage charts can be generated for any selected boiler for a wide range of operating conditions. For two selected boilers operating in any one of the hour-by-hour weather patterns which characterize each of six cities over a wide range of firing rates, domestic hot water consumption rates, design heat loads, and energy (re) capture rates, annual fuel usages are determined and graphically presented. Figures 1 to 98, inclusive, relate to installations for which energy recapture rates are taken to be zero. Figures 97 to 130, inclusive, apply to a range of cases for which energy recapture rates are nonzero and determinable. In all cases, simple, direct and reliable annual fuel usage values can be determined by use of charts and methods such as those illustrated.

Berlad, A.L.; Yeh, Y.J.; Salzano, F.J.; Hoppe, R.J.; Batey, J.

1978-07-01T23:59:59.000Z

234

Testing and analysis of load-side immersed heat exchangers for solar domestic hot water systems  

DOE Green Energy (OSTI)

This report describes work to determine the performance of load-side heat exchangers for use in residential solar domestic hot water systems. We measured the performance of four heat exchangers: a smooth coil and a finned coil having heat transfer areas of 2.5 m/sup 2/ (26 ft/sup 2/) and those having areas of 1.7 m/sup 2/ (19 ft/sup 2/). A numerical model using the thermal network program MITAS was constructed, and results were compared to the experimental results. Research showed a smooth coil with only 70% of the surface area of a finned coil performed better than the finned coil. Also, load-side heat exchangers can maintain and enhance stratification in storage tanks, permitting the use of control strategies that take advantage of stratified storage tanks to increase system performance. The analytical model, which agreed reasonably well with the experimental results, was used to vary heat exchanger flow rate and area and initial tank temperature for both a smooth- and a finned-coil heat exchanger. Increasing the heat exchanger flow rate and area results in higher heat transfer rates but not necessarily optimal performance. Lower initial tank temperatures resulted in reduced tank stratification. The smooth heat exchanger outperformed the finned heat exchanger with the same outside surface area. 15 refs., 37 figs., 9 tabs.

Farrington, R.B.; Bingham, C.E.

1987-10-01T23:59:59.000Z

235

Light-stable-isotope studies of spring and thermal waters from the Roosevelt Hot Springs and Cove Fort/Sulphurdale Thermal areas and of clay minerals from the Roosevelt Hot Springs thermal area  

DOE Green Energy (OSTI)

The isotopic compositions of hydrogen and oxygen have been determined for spring waters and thermal fluids from the Roosevelt Hot Springs and Cove Fort-Sulphurdale thermal areas, for clay mineral separates from shallow alteration of the acid-sulfate type in the Roosevelt Hot Springs area, and for spring and well waters from the Goshen Valley area of central Utah. The water analyses in the Roosevelt Hot Springs thermal area confirm the origin of the thermal fluids from meteoric water in the Mineral Range. The water analyses in the Cove Fort-Sulphurdale thermal area restrict recharge areas for this system to the upper elevations of the Pavant and/or Tushar Ranges. The low /sup 18/O shift observed in these thermal fluids (+0.7 permil) implies either high water/rock ratios or incomplete isotope exchange or both, and further suggests minimal interaction between the thermal fluid and marble country rock in the system. Hydrogen and oxygen-isotope data for clay mineral separates from shallow alteration zones in the Roosevelt Hot Springs thermal system suggest that the fluids responsible for the shallow acid-sulfate alteration were in part derived from condensed steam produced by boiling of the deep reservoir fluid. The isotope evidence supports the chemical model proposed by Parry et al. (1980) for origin of the acid-sulfate alteration at Roosevelt Hot Springs. The isotope analyses of spring and well waters from the Goshen Valley area indicate only a general correlation of isotope composition, salinity and chemical temperatures.

Bowman, J.R.; Rohrs, D.T.

1981-10-01T23:59:59.000Z

236

Cost effective solar hot water system for Econo-Travel Motor Hotel located at Bluefield, West Virginia. Final report  

SciTech Connect

The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 3400 Cumberland Road, Bluefield, West Virginia. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately five (5) years instead of the 7.73 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. The success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

1979-07-01T23:59:59.000Z

237

Cost effective solar hot water system for Econo-Travel Motor Hotel located at Richmond, Virginia. Final report  

SciTech Connect

The final report is presented of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 5408 Williamsburg Road, Richmond, Virginia. The description of the system is given along with the final cost breakdown, expected performance data and expected payback time for the installed system is estimated to be approximately five (5) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. The success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

1979-09-01T23:59:59.000Z

238

Impact of a solar domestic hot water demand-side management program on an electric utility and its customers  

DOE Green Energy (OSTI)

A methodology to assess the economic and environmental impacts of a large scale implementation of solar domestic hot water (SDHW) systems is developed. Energy, emission and demand reductions and their respective savings are quantified. It is shown that, on average, an SDHW system provides an energy reduction of about 3200 kWH, avoided emissions of about 2 tons and a capacity contribution of 0.7 kW to a typical Wisconsin utility that installs 5000 SDHW system. The annual savings from these reductions to utility is {dollar_sign}385,000, providing a return on an investment of over 20{percent}. It is shown that, on average, a consumer will save {dollar_sign}211 annually in hot water heating bills. 8 refs., 7 figs.

Trzeniewski, J.; Mitchell, J.W.; Klein, S.A.; Beckman, W.A.

1996-09-01T23:59:59.000Z

239

Cost effective solar hot water system for Econo-Travel Motor Hotel located at Woodbrdge, VA. Final report  

SciTech Connect

The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 13317 Gordon Boulevard, Woodbridge, Virginia is given. The description of the system along with the final breakdown, performance data and payback time are given. The payback time for the installed system will be approximately four (4) years instead of the 7.2 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. As called for in the proposal to DOE, the success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

1978-11-01T23:59:59.000Z

240

Cost effective solar hot water system for Econo-Travel Motor Hotel located at Bluefield, West Virginia. Final report  

DOE Green Energy (OSTI)

The final report of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 3400 Cumberland Road, Bluefield, West Virginia. The description of the system along with the final breakdown performance data and payback time are given. The payback time for the installed system will be approximately five (5) years instead of the 7.73 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. The success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

Not Available

1979-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Cost effective solar hot water system for Econo-Travel Motor Hotel located at Richmond, Virginia. Final report  

DOE Green Energy (OSTI)

The final report is presented of a cost effective solar hot water heating system installed on the Econo-Travel Motor Hotel at 5408 Williamsburg Road, Richmond, Virginia. The description of the system is given along with the final cost breakdown, expected performance data and expected payback time for the installed system is estimated to be approximately five (5) years instead of the 6.65 years estimated for the proposal. The additional savings is due to the reduction in the peak demand charge since the electric hot water heaters are not required to operate at the same time each morning as the dryers used for the laundry. The success of the system will be determined by the reduction in the utility cost and reduced use of our fossil fuels. The results shown in the hotel's monthly electricity bills indicate that this goal has been accomplished.

Not Available

1979-09-01T23:59:59.000Z

242

Schematisation of Tree Drawings  

E-Print Network (OSTI)

Abstract. Given a tree T spanning a set of points S in the plane, we study the problem of drawing T using only line segments aligned with a fixed set of directions C. The vertices in the drawing must lie within a given distance r of each original point p ? S, and an objective function counting the number of bends must be minimised. We propose five versions of this problem using different objective functions, and algorithms to solve them. This work has potential applications in geographic map schematisation and metro map layout. 1

Joachim Gudmundsson; Marc Van Kreveld; Damian Merrick

2006-01-01T23:59:59.000Z

243

Characterization equipment essential drawing plan  

SciTech Connect

The purpose of this document is to list the Characterization equipment drawings that are classified as Essential Drawings and Support Drawings. Essential Drawings: Are those drawings identified by the facility staff as necessary to directly support the safe operation of the facility or equipment (HNF 1997a). Support Drawings: Are those drawings identified by facility staff that further describe the design details of structures, systems, or components shown on essential drawings. (HNF 1997a) The Characterization equipment drawings identified in this report are deemed essential drawings as defined in HNF-PRO-242, Engineering Drawing Requirements (HNF 1997a). These drawings will be prepared, revised, and maintained per HNF-PRO-440, Engineering Document Change Control (HNF 1997b). All other Characterization equipment drawings not identified in this document will be considered General drawings until the Characterization Equipment Drawing Evaluation Report (Wilson 1998) is updated during fiscal year 1999. Trucks 1 and 2 drawings are not included in this revision of the essential drawing list due to uncertainty about future use.

WILSON, G.W.

1999-05-14T23:59:59.000Z

244

Solar process heat technology in action: The process hot water system at the California Correctional Institution at Tehachapi  

DOE Green Energy (OSTI)

Solar process heat technology relates to solar thermal energy systems for industry, commerce, and government. Applications include water preheating and heating, steam generation, process hot air, ventilation air heating, and refrigeration. Solar process heat systems are available for commercial use. At the present time, however, they are economically viable only in niche markets. This paper describes a functioning system in one such market. The California Department of Corrections (CDOC), which operates correctional facilities for the state of California, uses a solar system for providing hot water and space heating at the California Correctional Institute at Tehachapi (CCI/Tehachapi). CCI/Tehachapi is a 5100-inmate facility. The CDOC does not own the solar system. Rather, it buys energy from private investors who own the solar system located on CCI/Tehachapi property; this arrangement is part of a long-term energy purchase agreement. United Solar Technologies (UST) of Olympia Washington is the system operator. The solar system, which began operating in the fall of 1990, utilizes 2677 m{sup 2} (28,800 ft{sup 2}) of parabolic through solar concentrators. Thermal energy collected by the system is used to generate hot water for showers, kitchen operations, and laundry functions. Thermal energy collected by the system is also used for space heating. At peak operating conditions, the system is designed to meet approximately 80 percent of the summer thermal load. 4 figs., 4 tabs.

Hewett, R. [National Renewable Energy Lab., Golden, CO (United States); Gee, R.; May, K. [Industrial Solar Technology, Arvada, CO (United States)

1991-12-01T23:59:59.000Z

245

Report on the analysis of field data relating to the reliability of solar hot water systems.  

DOE Green Energy (OSTI)

Utilities are overseeing the installations of thousand of solar hot water (SHW) systems. Utility planners have begun to ask for quantitative measures of the expected lifetimes of these systems so that they can properly forecast their loads. This report, which augments a 2009 reliability analysis effort by Sandia National Laboratories (SNL), addresses this need. Additional reliability data have been collected, added to the existing database, and analyzed. The results are presented. Additionally, formal reliability theory is described, including the bathtub curve, which is the most common model to characterize the lifetime reliability character of systems, and for predicting failures in the field. Reliability theory is used to assess the SNL reliability database. This assessment shows that the database is heavily weighted with data that describe the reliability of SHW systems early in their lives, during the warranty period. But it contains few measured data to describe the ends of SHW systems lives. End-of-life data are the most critical ones to define sufficiently the reliability of SHW systems in order to answer the questions that the utilities pose. Several ideas are presented for collecting the required data, including photometric analysis of aerial photographs of installed collectors, statistical and neural network analysis of energy bills from solar homes, and the development of simple algorithms to allow conventional SHW controllers to announce system failures and record the details of the event, similar to how aircraft black box recorders perform. Some information is also presented about public expectations for the longevity of a SHW system, information that is useful in developing reliability goals.

Menicucci, David F. (Building Specialists, Inc., Albuquerque, NM)

2011-07-01T23:59:59.000Z

246

SOLERAS - Solar Energy Water Desalination Project: Chicago Bridge and Iron Company. Final report: system design extension. Volume 2. Appendices and drawings  

Science Conference Proceedings (OSTI)

The report concerns the design of a solar energy powered, seawater desalination pilot plant for installation at Yanbu, Saudi Arabia, on the shore of the Red Sea. General specifications, major equipment specifications, vendor and operation and maintenance information, as well as design drawings, are presented.

Not Available

1985-01-01T23:59:59.000Z

247

Don't Let Your Money and Hot Water Go Down the Drain | Department...  

NLE Websites -- All DOE Office Websites (Extended Search)

recovery systems capture some of this energy to preheat cold water entering the water heater or going to other water fixtures. How It Works In its simplest form, a drain-water...

248

Field monitoring of solar domestic hot water systems based on simple tank temperature measurement  

DOE Green Energy (OSTI)

By dynamically measuring solar storage tank temperature(s), the solar storage tank effectively becomes a dynamic calorimeter to measure the energy flows in a solar system. The energy flows include solar loop gain, tank losses, and potentially draw extraction. With one-channel temperature loggers storing data over several days to several weeks, this approach provides low-cost, modest-accuracy performance assessment, useful for determination of savings persistence and diagnostics. Analysis is based upon the tank energy balance, identifying solar gain during the day and tank losses at night. These gains and losses can be compared to expectations based upon prior knowledge, and estimated weather conditions. Diagnostics include controller and pump operation, and excessive nighttime losses. With one point temperature logger, solar gain accuracy is expected to be 20 to 50%, depending on draw frequency and volume. Two examples are shown, a properly operating system and a system with excessive nighttime losses.

Burch, J.; Xie, Yuantao [National Renewable Energy Lab., Golden, CO (United States); Murley, C.S. [Sacramento Municipal Utility District, CA (United States)

1995-05-01T23:59:59.000Z

249

A comparison of central and individual systems for space conditioning and domestic hot water in new multifamily buildings  

SciTech Connect

This report compares the energy performance and life-cycle cost of central and individual heating, ventilating, and air-conditioning (HVAC) systems as well as domestic hot water (DHW) systems in new multifamily buildings. The different systems were analyzed by using DOE-2.1C to model prototypical apartment buildings in Chicago and Atlanta with Weather Year for Energy Calculation weather data. The building is equipped with either a central chiller and gas-fired boiler, which supply four-pipe fan coils in each apartment, or is conditioned by individual packaged terminal air conditioners in each apartment. The building with central HVAC also has a central, gas-fired domestic hot water system; the building with individual units has electric water heaters in each apartment. The individual systems were modeled with and without a setback thermostat. The use of natural gas for space and water heating and the more efficient central chiller resulted in an annual energy cost savings for the central system in both cities. A life-cycle cost comparison of system types shows that apartment buildings with as few as five units in Chicago and as few as 30 units in Atlanta should be designed with central HVAC and DHW systems.

Byrne, S.J. (Lawrence Berkeley Lab., Berkeley, CA (US)); Fay, J.M. (Gas Research Inst., Chicago, IL (US))

1989-01-01T23:59:59.000Z

250

Potential of solar domestic hot water systems in rural areas for greenhouse gas emission reduction in Poland  

SciTech Connect

Application of solar energy for preparing domestic hot water is one of the easiest methods of utilization of this energy. At least part of the needs for warm tap water could be covered by solar systems. At present, mainly coal is used for water heating at dwellings in rural areas in Poland. Warm tap water consumption will increase significantly in the future as standards of living are improved. This can result in the growth of electricity use and an increase in primary fuel consumption. Present and future methods of warm sanitary water generation in rural areas in Poland is discussed, and associated greenhouse gas (GHG) emissions are estimated. It is predicted that the emission of CO{sub 2} and NOx will increase. The emission of CO and CH{sub 4} will decrease because of changes in the structure of the final energy carriers used. The economic and market potentials of solar energy for preparing warm water in rural areas are discussed. It is estimated that solar systems can meet 30%-45% of the energy demand for warm water generation in rural areas at a reasonable cost, with a corresponding CO{sub 2} emission reduction. The rate of realization of the economic potential of solar water heaters depends on subsidies for the installation of equipment. 13 refs., 9 tabs.

Skowronski, P. [Polish Foundation for Energy Efficiency, Warsaw (Poland); Wisniewski, G. [Institute for Building, Mechanization and Electrification of Agriculture, Warsaw (Poland)

1996-09-01T23:59:59.000Z

251

Pilot Phase of a Field Study to Determine Waste of Water and Energy in Residential Hot-Water Distribution Systems  

E-Print Network (OSTI)

understanding the waste of energy and water in residentialStudy to Determine Waste of Water and Energy in ResidentialStudy to Determine Waste of Water and Energy in Residential

Lutz, Jim

2012-01-01T23:59:59.000Z

252

Development of a gas backup heater for solar domestic hot-water systems. Final report, April 1978-April 1980  

DOE Green Energy (OSTI)

A comprehensive program was undertaken to develop a unique gas fired backup for solar domestic hot water systems. Detailed computer design tools were written. A series of heat transfer experiments were performed to characterize the performance of individual components. A full scale engineering prototype, including the solar preheat tank and solar heat exchanger, was designed, fabricated and subjected to limited testing. Firing efficiency for the backup system was found to be 81.4% at a firing rate of 50,000 Btu/h. Long term standby losses should be negligible.

Morrison, D.J.; Grunes, H.E.; de Winter, F.; Armstrong, P.R.

1980-06-01T23:59:59.000Z

253

Prediction of Severe Accident Counter Current Natural Circulation Flows in the Hot Leg of a Pressurized Water Reactor  

Science Conference Proceedings (OSTI)

During certain phases of a severe accident in a pressurized water reactor (PWR), the core becomes uncovered and steam carries heat to the steam generators through natural circulation. For PWR's with U-tube steam generators and loop seals filled with water, a counter current flow pattern is established in the hot leg. This flow pattern has been experimentally observed and has been predicted using computational fluid dynamics (CFD). Predictions of severe accident behavior are routinely carried out using severe accident system analysis codes such as SCDAP/RELAP5 or MELCOR. These codes, however, were not developed for predicting the three-dimensional natural circulation flow patterns during this phase of a severe accident. CFD, along with a set of experiments at 1/7. scale, have been historically used to establish the flow rates and mixing for the system analysis tools. One important aspect of these predictions is the counter current flow rate in the nearly 30 inch diameter hot leg between the reactor vessel and steam generator. This flow rate is strongly related to the amount of energy that can be transported away from the reactor core. This energy transfer plays a significant role in the prediction of core failures as well as potential failures in other reactor coolant system piping. CFD is used to determine the counter current flow rate during a severe accident. Specific sensitivities are completed for parameters such as surge line flow rates, hydrogen content, as well as vessel and steam generator temperatures. The predictions are carried out for the reactor vessel upper plenum, hot leg, a portion of the surge line, and a steam generator blocked off at the outlet plenum. All predictions utilize the FLUENT V6 CFD code. The volumetric flow in the hot leg is assumed to be proportional to the square root of the product of normalized density difference, gravity, and hydraulic diameter to the 5. power. CFD is used to determine the proportionality constant in the range from 0.11 to 0.13 and termed a discharge coefficient. The value is relatively unchanged for typical surge line flow rates as well as the hydrogen content in the flow. Over a significant range of expected temperature differences for the steam generator and reactor vessel upper plenum, the discharge coefficient also remained consistent. The discharge coefficient is a suitable model for determining the hot leg counter current flow rates during this type of severe accident. (author)

Boyd, Christopher F. [United States Nuclear Regulatory Commission, Washington, DC 20555-0001 (United States)

2006-07-01T23:59:59.000Z

254

In-situ parameter estimation for solar domestic hot water heating systems components. Final report, June 1995--May 1996  

DOE Green Energy (OSTI)

Three different solar domestic hot water systems are being tested at the Colorado State University Solar Energy Applications Laboratory; an unpressurized drain-back system with a load side heat exchanger, an integral collector storage system, and an ultra low flow natural convection heat exchanger system. The systems are fully instrumented to yield data appropriate for in-depth analyses of performance. The level of detail allows the observation of the performance of the total system and the performance of the individual components. This report evaluates the systems based on in-situ experimental data and compares the performances with simulated performances. The verification of the simulations aids in the rating procedure. The whole system performance measurements are also used to analyze the performance of individual components of a solar hot water system and to develop improved component models. The data are analyzed extensively and the parameters needed to characterize the systems fully are developed. Also resulting from this indepth analysis are suggested design improvements wither to the systems or the system components.

Smith, T.R.

1997-03-01T23:59:59.000Z

255

Performance and economic evaluation of the seahorse natural gas hot water heater conversion at Fort Stewart. Interim report, 1994 Summer  

Science Conference Proceedings (OSTI)

The federal government is the largest single energy consumer in the United States cost valued at nearly $10 billion annually. The US Department of Energy`s (DOE) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the federal sector. One such effort, the New Technology Demonstration Program (NTDP), seeks to evaluate new energy-saving US technologies and secure their more timely adoption by the US government. Pacific Northwest Laboratory (PNL) is one of four DOE laboratories that participate in the New Technologies Demonstration Program, providing technical expertise and equipment to evaluate new, energy-saving technologies being studied under that program. This interim report provides the results of a field evaluation that PNL conducted for DOE/FEMP and the US Department of Defense (DoD) Strategic Environmental Research and Development Program (SERDP) to examine the performance of a candidate energy-saving technology-a hot water heater conversion system to convert electrically heated hot water tanks to natural gas fuel. The unit was installed at a single residence at Fort Stewart, a US Army base in Georgia, and the performance was monitored under the NTDP. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) were Gas Fired Products, developers of the technology; the Public Service Company of North Carolina; Atlanta Gas Light Company; the Army Corps of Engineers; Fort Stewart; and Pacific Northwest Laboratory.

Winiarski, D.W.

1995-01-01T23:59:59.000Z

256

Geochemistry of thermal/mineral waters in the Clear Lake region, California, and implications for hot dry rock geothermal development  

DOE Green Energy (OSTI)

Thermal/mineral waters of the Clear Lake region are broadly classified as thermal meteoric and connote types based on chemical and isotopic criteria. Ratios of conservative components such as B/Cl are extremely different among all thermal/mineral waters of the Clear Lake region except for clusters of waters emerging from specific areas such as the Wilbur Springs district and the Agricultural Park area south of Mt. Konocti. In contrast, ratios of conservative components in large, homogeneous geothermal reservoirs are constant. Stable isotope values of Clear Lake region waters show a mixing trend between thermal meteoric and connote end-members. The latter end-member has enriched [delta]D as well as enriched d[sup l8]O, very different from typical high-temperature geothermal reservoir waters. Tritium data and modeling of ages indicate most Clear Lake region waters are 500 to > 10,000 yr., although mixing of old and young components is implied by the data. The age of end-member connate water is probably > 10,000 yr. Subsurface equilibration temperature of most thermal/mineral waters of the Clear Lake region is [le] 150[degrees]C based on chemical geothermometers but it is recognized that Clear Lake region waters are not typical geothermal fluids and that they violate rules of application of many geothermometers. The combined data indicate that no large geothermal reservoir underlies the Clear Lake region and that small localized reservoirs have equilibration temperatures [le] 150[degrees]C (except for Sulphur Bank Mine). Hot dry rock technologies are the best way to commercially exploit the known high temperatures existing beneath the Clear Lake region, particularly within the main Clear Lake volcanic field.

Goff, F.; Adams, A.I.; Trujillo, P.E.; Counce, D.; Mansfield, J.

1993-02-01T23:59:59.000Z

257

Water and Energy Wasted During Residential Shower Events: Findings from a Pilot Field Study of Hot Water Distribution Systems  

E-Print Network (OSTI)

the shower only. The wasted energy is the difference betweenLBNL-5115E Water and Energy Wasted During Residential Showercalculate the water and energy wasted during shower events

Lutz, Jim

2012-01-01T23:59:59.000Z

258

Performance Evaluation of Hot Water Efficiency Plumbing System Using Thermal Valve  

E-Print Network (OSTI)

In Korea two popular water distribution systemsthe branch type and the separate type systemshave serious drawbacks. The branch type suffers from temperature instability while the separate type suffers from excessive piping. Neither of them re-circulates water. The system proposed in this paper utilizes a water-conserving piping system with a thermostat valve. This paper compares the proposed system with that of the separate type. Our findings show that the proposed system wastes less water. After re-circulating for 78-87 seconds, water is available at set point temperature (40C). Also, when multiple water taps are in use, the average temperature deviation is less than 0.6C. Moreover, the proposed system has 50% less flow rate than the separate type system.

Cha, K. S.; Park, M. S.; Seo, H. Y.

2010-08-01T23:59:59.000Z

259

Application of solar energy to the supply of industrial process hot water: preliminary design and performance report. Volume I. Technical report. Aerotherm report TR-76-219. [For can washing at Campbell Soup Plant in Sacramento  

DOE Green Energy (OSTI)

The design and performance of a solar hot water system for can washing at the Campbell Soup Plant in Sacramento, California, are presented. The collector field is located on the roof of the finished products warehouse of the Campbell Soup Sacramento plant. Water is supplied from a 3.8 cm (1/sup 1///sub 2/ in.) supply line which is located directly below an existing roof access hatch. A supply pipe will be brought up through that hatch. The water flow will then be split into two manifold lines which supply the dual rows of flat plate collectors. The preheated water from the flat plates is then passed into six sets of parallel connected concentrators. Each set consist of eight 1.83 x 3.05 m (6 x 10 foot) modules connected in series. The water from these units is gathered in a 3.8 cm (1/sup 1///sub 2/ in.) insulated pipe which transports it to the storage tank. This pipe will be attached to an existing pipe run until it reaches the can washing building. From there the pipe will follow the can washing building around to the storage tank. The storage tank is a 75,200 1 (20,000 gal) steel tank which is coated internally with a USDA approved phenolic liner. The outside of the tank is insulated. A 2.2 kw (3 hp) motor is used to pump the stored water for the tank into the can washing line. Detail drawings and descriptions of the collector field, installation, piping, controls, data acquisition equipment, and roof structure are included. Furthermore, a program schedule with equipment and manpower costs for successfully completing Phase II of this contract is included. Also included is an organization chart of the Phase II program personnel. (WHK)

None

1976-10-14T23:59:59.000Z

260

Solar preheating of both domestic hot water and space. Final technical report for the Sea Loft restaurant in Long Branch, New Jersey  

Science Conference Proceedings (OSTI)

Stephen Giddio's Sea Loft Restaurant in Long Branch, NJ is equipped with an active solar system for preheating water for both space heating and domestic hot water. Three pumped water loops, each a closed circuit, transfer heat from one major component to another. Solar heat is collected by an array of 83 evacuated tube collectors. The acceptance test results are appended, as well as the operational and maintenance manual. Reference CAPE-2805. (LEW)

Not Available

1982-11-28T23:59:59.000Z

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Design manual for solar heating of buildings and domestic hot water  

SciTech Connect

This manual presents design and cost analysis methods for sizing and payback estimating of solar heat collectors for augmentation of portable water heaters and space heaters. Sufficient information is presented to enable almost anyone to design solar space and water heating systems or conduct basic feasibility studies preparatory to design of large installations. Both retrofit and new installations are considered. (MOW)

Field, R.L.

1977-01-01T23:59:59.000Z

262

Manhattan Project: CP-1 Drawing  

Office of Scientific and Technical Information (OSTI)

Drawing of CP-1 Events > Difficult Choices, 1942 > Picking Horses, November 1942 Events > The Plutonium Path to the Bomb, 1942-1944 > Production Reactor (Pile) Design, Met Lab,...

263

Case Study of Stratified Chilled Water Storage Utilization for Comfort and Process Cooling in a Hot, Humid Climate  

E-Print Network (OSTI)

The advantages of thermal storage are enhanced in hot and humid climates. Year-round cooling loads increase thermal storage operating cost savings. The absence of a long winter during which major maintenance tasks can be accomplished without compromising system reliability increases the importance of thermal storage as back-up capacity. In an industrial setting, operating cost savings due to thermal storage go directly to the bottom line of a manufacturing process and the avoidance of lost production due to process cooling outages can save millions of dollars per year. This paper presents a case study of chilled water storage use at the campus of a major US electronics manufacturer located in Dallas, TX. An overview of the system and its operation is followed by presentation of operating data taken during 1997.

Bahnfleth, W. P.; Musser, A.

1998-01-01T23:59:59.000Z

264

Feasibility study and roadmap to improve residential hot water distribution systems  

E-Print Network (OSTI)

perspective, the sink and dishwashers must be considered incool off once again. For dishwashers, not only is the energyit must be made up by the dishwasher heating the cool water

Lutz, James D.

2004-01-01T23:59:59.000Z

265

Effects of plumbing attachments on heat losses from solar domestic hot water storage tanks. Final report, Part 2  

DOE Green Energy (OSTI)

The Solar Rating and Certification Corporation (SRCC) has established a standardized methodology for determining the performance rating of the Solar Domestic Hot Water (SDHW) systems it certifies under OG-300. Measured performance data for the solar collector component(s) of the system are used along with numerical models for the balance of the system to calculate the system`s thermal performance under a standard set of rating conditions. SRCC uses TRNSYS to model each of the components that comprise the system. The majority of the SRCC certified systems include a thermal storage tank with an auxiliary electrical heater. The most common being a conventional fifty gallon electric tank water heater. Presently, the thermal losses from these tanks are calculated using Q = U {center_dot} A {center_dot} {Delta}T. Unfortunately, this generalized formula does not adequately address temperature stratification both within the tank as well as in the ambient air surrounding the tank, non-uniform insulation jacket, thermal siphoning in the fluid lines attached to the tank, and plumbing fittings attached to the tank. This study is intended to address only that part of the problem that deals with the plumbing fittings attached to the tank. Heat losses from a storage tank and its plumbing fittings involve three different operating modes: charging, discharging and standby. In the charging mode, the tank receives energy from the solar collector. In the discharge mode, water flows from the storage tank through the distribution pipes to the faucets and cold city water enters the tank. In the standby mode, there is no forced water flow into or out of the tank. In this experimental study, only the standby mode was considered.

Song, J.; Wood, B.D. [Univ. of Nevada, Reno, NV (United States); Ji, L.J. [Arizona State Univ., Tempe, AZ (United States)

1998-03-01T23:59:59.000Z

266

Stereoscopic 3D line drawing  

Science Conference Proceedings (OSTI)

This paper discusses stereoscopic 3D imaging based on line drawing of 3D shapes. We describe the major issues and challenges in generating stereoscopic 3D effects using lines only, with a couple of relatively simple approaches called each-eye-based and ... Keywords: binocular rivalry, line drawing, line stylization, non-photorealism, stereo coherence, stereoscopy

Yongjin Kim; Yunjin Lee; Henry Kang; Seungyong Lee

2013-07-01T23:59:59.000Z

267

Application of solar energy to the supply of industrial hot water. Technical report 4  

SciTech Connect

A solar water heating and steam generating system is being designed for a California laundry. Progress reported includes completion of the analysis of the existing process services, determination of collectable solar energy at El Centro, California, selection of water as the heat transfer fluid in the 200/sup 0/F system and further analyses of heat transfer fluids for the 300/sup 0/F system, meetings and discussions with respect to system controls and monitoring and the collector support structure, and a proposal for the waste heat recovery system. (LEW)

1976-09-01T23:59:59.000Z

268

Regulatory, Land Ownership, and Water Availability Factors for a Magma Well: Long Valley Caldera and Coso Hot Springs, California  

DOE Green Energy (OSTI)

The U.S. Department of Energy is currently engaged in a program to demonstrate the engineering feasibility of extracting thermal energy from high-level molten magma bodies. The program is being carried out under the direction of Sandia National Laboratories where a number of individual projects support the overall program. The existing program elements include (1) high-temperature materials compatibility testing; (2) studies of properties of melts of various compositions; and (3) the investigation of the economics of a magma energy extraction system. Another element of the program is being conducted with the cooperation of the U.S. Geological Survey, and involves locating and outlining magma bodies at selected sites using various geophysical techniques. The ultimate goal here will be to define the limits of a magma body as a drilling target. During an earlier phase of the program, more than twenty candidate study sites considered were evaluated based upon: (1) the likelihood of the presence of a shallow magma chamber, (2) the accessibility of the site, and (3) physical and institutional constraints associated with each site with respect to performing long-term experiments. From these early phase activities, the number of candidate sites were eventually narrowed to just 2. The sites currently under consideration are Coso Hot Springs and the Long Valley caldera (Figure 1). This report describes certain attributes of these sites in order to help identify potential problems related to: (1) state and federal regulations pertaining to geothermal development; (2) land ownership; and (3) water resource availability. The information sources used in this study were mainly maps, publications, and informative documents gathered from the California Division of Oil and Gas and the U.S. Department of the Interior. Environmental studies completed for the entire Long Valley caldera study area, and for portions of the Coso Hot Springs study area were also used for reference.

Blackett, Robert

1985-09-01T23:59:59.000Z

269

Application of solar energy to the supply of industrial hot water. Technical report 3  

SciTech Connect

A solar water heating and steam generating system is being developed for a California laundry. Progress reported includes accumulation of data on process usage and demands for the purpose of collector sizing, studies of insulation for piping and thermal storage tanks, investigation in the selection of the heat transfer fluid, and weather measurements. Further analyses on the supporting structure for the solar collector arrays are reported. A concept review meeting is discussed. (LEW)

1976-08-01T23:59:59.000Z

270

Economic viability of heat pump desuperheaters for supplying domestic hot water  

Science Conference Proceedings (OSTI)

The heat reclaimer is a heat exchange device that removes superheat from the refrigerant gas in a heat pump or central air conditioning unit and uses that extracted energy to heat water for domestic uses. This analysis examines the energy-saving potential and economic benefit of the heat reclaimer. Energy savings were calculated using a modified bin analytical technique. Economic viability was determined using the simple payback criterion. The analysis was performed for 28 cities in the United States to gain an understanding of the relationship between energy savings, economic viability, and climate. The results of the assessment indicate that the heat reclaimer has payback periods greater than seven years when compared with oil- or gas-fired water heating systems. Because of the long payback periods, the heat reclaimer does not appear to be economically feasible for these applications. However, when compared to electric-resistance water heating units, the heat reclaimer is economically viable, especially in areas where the air conditioning load is substantial or where the price of electricity is high.

Olszewski, M.

1984-01-01T23:59:59.000Z

271

A VISUAL STUDY OF THE CORROSION OF DEFECTED ZIRCALOY-2-CLAD FUEL SPECIMENS BY HOT WATER  

DOE Green Energy (OSTI)

The failure of defected Zircaloy-2-clad uranium and uranium -2 wt.% zircorium fuel specimens in high-purity high-pressure water at 200 to 345 deg C was observed in a windowed antcclave. Time-lapse color motion pictures were taken to provide a record of the progressive changes ending in the complete disintegration of the core material in the specimens. Continuous measurement of the pressure increase caused by accumulation of hydrogen served to monitor the progress of the reaction when clouding of the water by corrosion products made visual observation impossible. The nature of the attack of all specimens was similar, although the time at which different stages occurred varied. Following an induction period, the first evidence of attack was the slow formation of a blister in the cladding area surrounding the defect. Eventually, a copions evolution of hydrogen occurried at the base of the swollen area. In general, a crack could be seen in the cladding at this stage. Catastrophic failure of the specimen followed swiftly. The time required for each phase of the reaction was reduced as the temperature was raised. Initial swelling occurred after about 24 min at 345 deg C but only after 8 hr at 200 deg C. Diffusion-treated uranium2 wt.% zirconium-cored specimens were most resistant to attack. Specimens with beta-treated water-quenched natural-uranium cores were least resistant (auth)

Stephan, E.F.; Miller, P.D.; Fink, F.W.

1959-10-19T23:59:59.000Z

272

Solar preheating of both domestic hot water and space. Final technical report for the Sea Loft restaurant in Long Branch, New Jersey (Engineering Materials)  

Science Conference Proceedings (OSTI)

Stephen Giddio's Sea Loft Restaurant in Long Branch, NJ is equipped with an active solar system for preheating of both Space and Domestic Hot Water (DHW). Three pumped water loops, each closed circuit, transfer heat from one major equipment component to another. The closed loop drain back solar energy collection circuit uses a 3/4 horsepower pump to circulate seventeen gallons per minute of deionized water from the Solar Storage Tank to the Solar Collector Array, and return. This tank has a capacity of 600 gallons. The solar array consist of eighty-three evacuated tube type concentrating collectors. The heat gathered in this circuit is stored in the tank for either simultaneous or future use in either or both of the Space and DHW preheating loops. The preheating of city water prior to its entrance into the gas fired 86 gallon DHW heater is accomplished in a separate 600 gallon capacity tank. Two thirty-five square foot tubed heat exchanger bundles inserted into this tank accept solar heated hot water from the Solar Storage Tank. This solar heated water is pumped at sixteen GPM in a closed loop circuit using a 1/4 HP pump. The preheating of restaurant space is accomplished in a closed loop circuit between the Solar Storage Tank and an eight SF hot water coil inserted into the return air from the Main Dining Room of the restaurant. A 1/4 HP pump circulates fifteen gallons of solar heated hot water per minute. This system incorporates a differential temperature controller that utilizes a multitude of pressure sensors and temperature thermistors located throughout the various portions of the system components and piping. The Display Board mounted on the wall of the Bar-Lounge Area serves to integrate the entire solar system. It not only displays the flow but houses the Btu flowmeters, Digital temperature readouts, and HVAC EMS Programmer. Reference DOE/CS/30007-T1.

Not Available

1982-11-28T23:59:59.000Z

273

Stable isotope investigation of fluids and water-rock interaction in the Roosevelt Hot Springs thermal area, Utah  

DOE Green Energy (OSTI)

Carbon-hydrogen-oxygen isotope compositions have been measured in regional cold waters, geothermal fluids, and hydrothermally altered rocks from the Roosevelt Hot Springs geothermal area. These data have been used, in conjunction with other geological and geochemical data from this geothermal system, to place some limits on the origin of geothermal fluids and reservoir carbon, the fluid recharge area, physical-chemical environment of hydrothermal alteration, and relative permeability of the geothermal system. The similarity of hydrogen isotope compositions of local meteoric water and geothermal reservoir fluid indicate that the geothermal fluids are virtually entirely of surface derivation. An isotopically reasonable source area would be the Mineral Mountains directly to the east of the Roosevelt system. Hydrothermal calcite appears to be in isotopic equilibrium with the deep reservoir fluid. The deltaC/sup 13/ values of deep calcites and T- pH-f0/sub 2/ conditions of the reservoir defined by measured temperature, fluid chemistry, and alteration mineralogy fix the delta/sup 13/C value of the geothermal system to -5 to -6.5% (PDB). These values do not unambiguously define any one source or process, however. There is a relatively small increase in /sup 18/O of geothermal fluids relative to their cold surface water precursors and significant /sup 18/O depletion accompanying hydrothermal alteration of the granitic host rock. These isotopic shifts indicate a high ratio of geothermal fluid to altered rock for the geothermal system, implying relatively rapid (geologically) recirculation rates and significant permeability of the geothermal system.

Bowman, J.R.

1979-01-01T23:59:59.000Z

274

Standard Guide for On-Site Inspection and Verification of Operation of Solar Domestic Hot Water Systems  

E-Print Network (OSTI)

1.1 This guide covers procedures and test methods for conducting an on-site inspection and acceptance test of an installed domestic hot water system (DHW) using flat plate, concentrating-type collectors or tank absorber systems. 1.2 It is intended as a simple and economical acceptance test to be performed by the system installer or an independent tester to verify that critical components of the system are functioning and to acquire baseline data reflecting overall short term system heat output. 1.3 This guide is not intended to generate accurate measurements of system performance (see ASHRAE standard 95-1981 for a laboratory test) or thermal efficiency. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine th...

American Society for Testing and Materials. Philadelphia

1987-01-01T23:59:59.000Z

275

Validation of Hot Water and Lactic Acid Sprays for the Reduction of Enteric Pathogens on the Surface of Beef Carcasses  

E-Print Network (OSTI)

Escherichia coli O157:H7 and Salmonella have emerged as the most common foodborne enteric pathogens causing human illness from the consumption of beef. By mandate of the U.S. Department of Agriculture (USDA), Food Safety and Inspection Service (FSIS), the industry has implemented a Hazard Analysis and Critical Control Points (HACCP) system that utilize intervention technologies for controlling, preventing, and/or reducing enteric pathogens. In addition, USDA-FSIS has mandated that each facility must validate, monitor, and verify the effectiveness of each intervention implemented to eliminate E. coli O157:H7 and Salmonella. For this study, microbial decontamination interventions at two beef slaughter facilities were validated to demonstrate effectiveness in eliminating or reducing enteric pathogens. The facilities selected utilized either a lactic acid spray treatment or a combination of hot water followed by a lactic acid treatment. At both facilities, mesophilic plate counts (MPC) were significantly (P < 0.05) reduced, and E. coli and coliforms were eliminated below detectable limits at both facilities. No Salmonella positive samples were detected after either facility's intervention sequence. The framework used in this research to validate interventions can also be utilized in the future for yearly verification of the effectiveness of each intervention.

Wright, Kyle D.

2009-12-01T23:59:59.000Z

276

U.S. Marine Corps Base Camp Pendleton: Using The Sun For Hot Water And Electricity, Federal Energy Management Program (FEMP) (Fact Sheet)  

NLE Websites -- All DOE Office Websites (Extended Search)

U.S. Marine Corps Base Camp Pendleton, U.S. Marine Corps Base Camp Pendleton, covering 125,000 acres including 17 miles of Southern-California coastline, is the largest expeditionary training facility on the West Coast. More than 41,500 marines and family members call the base home, which reaches a daytime population of approximately 100,000. In fiscal year 2007, Camp Pendleton saved energy and money and reduced greenhouse gas (GHG) emissions through solar hot water (SHW) and photovoltaic (PV) arrays. The base implemented two integrated solar thermal/PV systems at its 53 Area and 62 Area training pools. The projects demonstrate Camp Pendleton's continuing commitment to energy conservation while helping meet Federal requirements for on-site renewable energy and solar hot water generation.

277

U.S. Marine Corps Base Camp Pendleton: Using The Sun For Hot Water And Electricity, Federal Energy Management Program (FEMP) (Fact Sheet)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

U.S. Marine Corps Base Camp Pendleton, U.S. Marine Corps Base Camp Pendleton, covering 125,000 acres including 17 miles of Southern-California coastline, is the largest expeditionary training facility on the West Coast. More than 41,500 marines and family members call the base home, which reaches a daytime population of approximately 100,000. In fiscal year 2007, Camp Pendleton saved energy and money and reduced greenhouse gas (GHG) emissions through solar hot water (SHW) and photovoltaic (PV) arrays. The base implemented two integrated solar thermal/PV systems at its 53 Area and 62 Area training pools. The projects demonstrate Camp Pendleton's continuing commitment to energy conservation while helping meet Federal requirements for on-site renewable energy and solar hot water generation.

278

Impacts of Water Quality on Residential Water Heating Equipment  

SciTech Connect

Water heating is a ubiquitous energy use in all residential housing, accounting for 17.7% of residential energy use (EIA 2012). Today, there are many efficient water heating options available for every fuel type, from electric and gas to more unconventional fuel types like propane, solar, and fuel oil. Which water heating option is the best choice for a given household will depend on a number of factors, including average daily hot water use (total gallons per day), hot water draw patterns (close together or spread out), the hot water distribution system (compact or distributed), installation constraints (such as space, electrical service, or venting accommodations) and fuel-type availability and cost. While in general more efficient water heaters are more expensive than conventional water heating technologies, the savings in energy use and, thus, utility bills can recoup the additional upfront investment and make an efficient water heater a good investment over time in most situations, although the specific payback period for a given installation will vary widely. However, the expected lifetime of a water heater in a given installation can dramatically influence the cost effectiveness and savings potential of a water heater and should be considered, along with water use characteristics, fuel availability and cost, and specific home characteristics when selecting the optimum water heating equipment for a particular installation. This report provides recommendations for selecting and maintaining water heating equipment based on local water quality characteristics.

Widder, Sarah H.; Baechler, Michael C.

2013-11-01T23:59:59.000Z

279

LANL Foundation conference draws teachers  

NLE Websites -- All DOE Office Websites (Extended Search)

LANL Foundation Conference Draws Teachers LANL Foundation Conference Draws Teachers Community Connections: Our link to Northern New Mexico Communities Latest Issue:Dec. 2013 - Jan. 2014 All Issues » submit LANL Foundation conference draws teachers The conference was made possible by a financial investment from LANS, LLC in the Foundation's Inquiry Science Education Consortium and from the Department of Energy. November 1, 2012 dummy image Read our archives Contacts Editor Linda Anderman Email Community Programs Office Kurt Steinhaus Email Close to 1,500 people, including teachers, principals, and others, attended the recent Los Alamos National Laboratory Foundation's 15th annual education conference. The speakers included Harry K. and Rosemary Wong on the subject of ""Effective Teaching."

280

Application of solar energy to the supply of industrial hot water. Volume 1. Final design report. [For American Linen Supply laundry in El Centro, California  

SciTech Connect

The conceptual design of a solar system for integration into the process hot water and steam services for the laundry facility, American Linen Sypply, located in El Centro, California is presented. A tracking parabolic collector array and thermal storage tanks will be used. Process analysis, instrumentation for control and data analysis, construction, maintenance and safety, energy reduction analysis, and economic analysis are described. A waste heat reclamation system is included in the design. (WHK)

1977-01-31T23:59:59.000Z

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Development and testing of a photometric method to identify non-operating solar hot water systems in field settings.  

DOE Green Energy (OSTI)

This report presents the results of experimental tests of a concept for using infrared (IR) photos to identify non-operational systems based on their glazing temperatures; operating systems have lower glazing temperatures than those in stagnation. In recent years thousands of new solar hot water (SHW) systems have been installed in some utility districts. As these numbers increase, concern is growing about the systems dependability because installation rebates are often based on the assumption that all of the SHW systems will perform flawlessly for a 20-year period. If SHW systems routinely fail prematurely, then the utilities will have overpaid for grid-energy reduction performance that is unrealized. Moreover, utilities are responsible for replacing energy for loads that failed SHW system were supplying. Thus, utilities are seeking data to quantify the reliability of SHW systems. The work described herein is intended to help meet this need. The details of the experiment are presented, including a description of the SHW collectors that were examined, the testbed that was used to control the system and record data, the IR camera that was employed, and the conditions in which testing was completed. The details of the associated analysis are presented, including direct examination of the video records of operational and stagnant collectors, as well as the development of a model to predict glazing temperatures and an analysis of temporal intermittency of the images, both of which are critical to properly adjusting the IR camera for optimal performance. Many IR images and a video are presented to show the contrast between operating and stagnant collectors. The major conclusion is that the technique has potential to be applied by using an aircraft fitted with an IR camera that can fly over an area with installed SHW systems, thus recording the images. Subsequent analysis of the images can determine the operational condition of the fielded collectors. Specific recommendations are presented relative to the application of the technique, including ways to mitigate and manage potential sources of error.

He, Hongbo (University of New Mexico, Albuquerque, NM); Vorobieff, Peter V. (University of New Mexico, Albuquerque, NM); Menicucci, David (University of New Mexico, Albuquerque, NM); Mammoli, Andrea A. (University of New Mexico, Albuquerque, NM); Carlson, Jeffrey J.

2012-06-01T23:59:59.000Z

282

On Water Flow in Hot Fractured Rock -- A Sensitivity Study on the Impact of Fracture-Matrix Heat Transfer  

E-Print Network (OSTI)

phases stored in matrix pores, the energy E M contained in VEnough energy is transmitted from the matrix to effectivelyfor energy transfer from the adjacent hot rock matrix rather

Birkholzer, Jens T.; Zhang, Yingqi

2005-01-01T23:59:59.000Z

283

On Water Flow in Hot Fractured Rock -- A Sensitivity Study on the Impact of Fracture-Matrix Heat Transfer  

E-Print Network (OSTI)

for both liquid and heat transfer processes. In order to beprocesses in hot fractured rock with ( 1) flow channeling in fractures, (2) interface reduction in F-M heat transfer,

Birkholzer, Jens T.; Zhang, Yingqi

2005-01-01T23:59:59.000Z

284

Engineering and economic evaluation of direct hot-water geothermal energy applications on the University of New Mexico campus. Final technical report  

DOE Green Energy (OSTI)

The potential engineering and economic feasibility of low-temperature geothermal energy applications on the campus of the University of New Mexico is studied in detail. This report includes three phases of work: data acquisition and evaluation, system synthesis, and system refinement and implementation. Detailed process designs are presented for a system using 190/sup 0/F geothermal water to substitute for the use of 135 x 10/sup 9/ Btu/y (141 TJ/y) of fossil fuels to provide space and domestic hot water heating for approximately 23% of the campus. Specific areas covered in the report include economic evaluation, environmental impact and program implementation plans.

Kauffman, D.; Houghton, A.V.

1980-12-31T23:59:59.000Z

285

ITL's TREC 2002 Draws Strong International Participation  

Science Conference Proceedings (OSTI)

ITL's Annual Information Retrieval Conference Draws Strong International Participation. The Information Access Division ...

286

Hot Springs | Open Energy Information  

Open Energy Info (EERE)

Springs Springs Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Hot Springs Dictionary.png Hot Springs: A naturally occurring spring of hot water, heated by geothermal processes in the subsurface, and typically having a temperature greater than 37°C. Other definitions:Wikipedia Reegle Modern Geothermal Features Typical list of modern geothermal features Hot Springs Fumaroles Warm or Steaming Ground Mudpots, Mud Pools, or Mud Volcanoes Geysers Blind Geothermal System Mammoth Hot Springs at Yellowstone National Park (reference: http://www.hsd3.org/HighSchool/Teachers/MATTIXS/Mattix%20homepage/studentwork/Laura%20Cornelisse%27s%20Web%20Page/Yellowstone%20National%20Park.htm) Hot springs occur where geothermally heated waters naturally flow out of the surface of the Earth. Hot springs may deposit minerals and spectacular

287

Thermal performance and economics of solar space and hot water heating system on Long Island, New York. [F-chart method  

DOE Green Energy (OSTI)

A practical method for designing solar space and water heating systems, called the ''f-chart'' method, is described with the results calculated for Long Island, New York. The solar heating systems to be considered consist of a solar collector which uses either liquid or air, an energy storage which can be either a water tank or a pebble bed, and an auxiliary energy source which supplies heat when solar energy is not available. Solar heated water from storage can be used either for space heating or for preheating the domestic hot water. The results of the ''f-chart'' analysis can simply be expressed as follows. For the thermal performance, Annual Load Fraction Supplied by Solar Energy versus Collector Area, and for the economic performance, Life Cycle Cost Savings versus Collector Area.

Auh, P C

1978-06-01T23:59:59.000Z

288

Implementation plan for the demonstration of a 50,000 ft/sup 2/ solar hot water system for the textile industry. Final report  

DOE Green Energy (OSTI)

An analysis of textile processes was conducted to determine their applicability to integration into a 50,000 ft/sup 2/ collector field and into a waste heat recovery system. Various processes in a typical carpet finishing plant, a typical cotton/cotton blend finishing plant, and a typical 100% synthetic fabric pressurized beck finishing plant are analyzed. The flat-plate, evacuated tube, and parabolic concentrator are discussed and evaluated. Evaluations of direct heat exchange, closed cycle enhanced recovery, and open cycle enhanced heat recovery techniques as applied to textile processes are presented. Conceptual designs are discussed that use a solar array to produce hot water and use standard boilers to produce process steam and to augment the hot water output when insolation values are insufficient to meet process demands. Conceptual designs and cost estimates are presented for: process water systems with evacuated tube solar collectors; process water system with concentrating-tracking solar collectors; feedwater system with concentrating-tracking solar collectors; templifier and direct exchange waste heat recovery system; direct heat recovery systems; integrated system using enhanced heat recovery and concentrating-tracking solar collectors; integrated system using direct heat recovery and concentrating-tracking solar collectors; integrated system using direct heat recovery, evacuated tube solar collectors and concentrating-tracking solar collectors; and integrated system using enhanced heat recovery, evacuated tube collectors, and concentrating-tracking source collectors. An economic evaluation of the systems is presented using the rate of return method. Results and recommendations are summarized. (MCW)

Hester, J.C.; Beasley, D.E.; Rogers, W.A. Jr.

1980-08-01T23:59:59.000Z

289

Detector of the flowing of a fluid in a pipe and energy saving device for a hot water system using this detector  

SciTech Connect

A fluid flow sensor, comprising a tubular element having a greater diameter than and vertically mounted on a pipe for serially interconnecting two portions of this pipe. One portion is connected to the upper end of the tubular element while the other portion is connected to its lower end. A magnetic piston is slidably mounted within the tubular element and is therefore free to move along it. A by-pass conduit interconnects the lower portion of the pipe with the upper portion of the pipe. The piston moves upwardly in the tubular element when the fluid flows. Fluid flows from the portion of the pipe connected at the lower end of the tubular element to the one connected at its upper end through the by-pass. The piston moves downwardly by gravity to the lower end of the tubular element when the fluid stops flowing. A coil wound around a portion of the tubular element produces in electrical signal when the piston moves in the tubular element. The piston has a frustroconical element on each end to absorb shocks which result when the piston seats in each position. This detecting device can be mounted on a hot water supply pipe and used in combination with an electronic circuit for saving energy in operating a hot water system. The electronic circuit allows or prevents the thermostat to control the water heating apparatus.

Lawless, J.

1985-02-05T23:59:59.000Z

290

Conceptual Drawing CMRR Facility Past  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Volume 1 Volume 1 Chapters 1 through 10 Appendices A through D To submit questions regarding this CMRR-NF SEIS, or to request a copy, please contact: AVAILABILITY OF THE FINAL SUPPLEMENTAL ENVIRONMENTAL IMPACT STATEMENT FOR THE NUCLEAR FACILITY PORTION OF THE CHEMISTRY AND METALLURGY RESEARCH BUILDING REPLACEMENT PROJECT AT LOS ALAMOS NATIONAL LABORATORY, LOS ALAMOS, NEW MEXICO (CMRR-NF SEIS) Printed with soy ink on recycled paper John Tegtmeier, EIS Document Manager Los Alamos Site Office National Nuclear Security Administration U.S. Department of Energy 3747 West Jemez Road Los Alamos, NM 87544 Telephone: 505-665-0113 Conceptual Drawing CMRR Facility Past Present Future Past Final Supplemental Environmental Impact Statement for the

291

Preliminary Modeling, Testing and Analysis of a Gas Tankless Water Heater  

SciTech Connect

Tankless water heaters offer significant energy savings over conventional storage-tank water heaters, because thermal losses to the environment are much less. Although standard test results are available to compare tankless heaters with storage tank heaters, actual savings depend on the draw details because energy to heat up the internal mass depends on the time since the last draw. To allow accurate efficiency estimates under any assumed draw pattern, a one-node model with heat exchanger mass is posed here. Key model parameters were determined from test data. Burner efficiency showed inconsistency between the two data sets analyzed. Model calculations show that efficiency with a realistic draw pattern is {approx}8% lower than that resulting from using only large {approx}40 liter draws, as specified in standard water-heater tests. The model is also used to indicate that adding a small tank controlled by the tankless heater ameliorates unacceptable oscillations that tankless with feedback control can experience with pre-heated water too hot for the minimum burner setting. The added tank also eliminates problematic low-flow cut-out and hot-water-delay, but it will slightly decrease efficiency. Future work includes model refinements and developing optimal protocols for parameter extraction.

Burch, J.; Thornton, J.; Hoeschele, M.; Springer, D.; Rudd, A.

2008-01-01T23:59:59.000Z

292

Experimental comparison of hot water/propane injection to steam/propane injection for recovery of heavy oil.  

E-Print Network (OSTI)

??Generating enough heat to convert water into steam is a major expense for projects that inject steam into reservoirs to enhance hydrocarbon recovery. If the (more)

Nesse, Thomas

2005-01-01T23:59:59.000Z

293

Heat-pump desuperheaters for supplying domestic hot water - estimation of energy savings and economic viability for residential applications  

SciTech Connect

The heat reclaimer is a double-wall heat exchange system that removes superheat from the heat pump (or central air conditioning) cycle and uses it to heat water for domestic uses. During summer operation, this heat would normally be rejected to the atmosphere without being used. Thus, water heating is accomplished using essentially no primary fuel. In winter, the heat extracted from the cycle would have been used for space heating. However, energy savings are possible above the heat pump balance point because water heating is performed at an enhanced efficiency. Potential energy savings and economic viability of the heat reclaimer were determined for 28 sites throughout the United States. These results indicate that the heat reclaimer is not economically attractive compared with gas- or oil-fired water heating systems. However, it is competitive with electric resistance water heaters. Based on these results, a calculational scheme has been developed that could be integrated into the model audit procedure.

Olszewski, M.; Fontana, E.C.

1983-05-01T23:59:59.000Z

294

Beppu hot springs  

SciTech Connect

Beppu is one of the largest hot springs resorts in Japan. There are numerous fumaroles and hot springs scattered on a fan-shaped area, extending 5 km (3.1 miles) from east to west and 8 km (5.0 miles) from north to south. Some of the thermal manifestations are called {open_quotes}Jigoku (Hells){close_quotes}, and are of interest to visitors. The total amount of discharged hot springs water is estimated to be 50,000 ton/day (9,200 gpm) indicating a huge geothermal system. The biggest hotel in Beppu (Suginoi Hotel) installed a 3-MW geothermal power plant in 1981 to generate electricity for its own private use.

Taguchi, Schihiro [Fukuoka Univ. (Japan); Itoi, Ryuichi [Kyushu Univ., Kasuga (Japan); Yusa, Yuki [Kyoto Univ., Beppu (Japan)

1996-05-01T23:59:59.000Z

295

NETL: Exploration Technologies - EOR Process Drawings  

NLE Websites -- All DOE Office Websites (Extended Search)

Exploration & Production Technologies Exploration Technologies - EOR Process Drawings Listed below are links to cross-sectional illustrations of Enhanced Oil Recovery (EOR)...

296

Performance Comparison of Residential Hot Water Systems; Period of Performance: January 30, 2001 through July 29, 2002  

DOE Green Energy (OSTI)

A laboratory test experiment was conducted to measure the energy performance of two different types of water heaters--electric storage tank and demand (tankless)--in two types of plumbing distribution systems--copper piping in a tree configuration and cross-linked polyethylene (PEX) piping in a parallel configuration. Two water-usage patterns were used in the week-long experiments and in the annual simulations: one representing a high-usage home and the other representing a low-usage home. Results of weekly performance testing and annual simulations of electric water-heating systems are presented.

Wiehagen, J.; Sikora, J. L.

2003-03-01T23:59:59.000Z

297

Hot air drum evaporator  

DOE Patents (OSTI)

An evaporation system for aqueous radioactive waste uses standard 30 and 55 gallon drums. Waste solutions form cascading water sprays as they pass over a number of trays arranged in a vertical stack within a drum. Hot dry air is circulated radially of the drum through the water sprays thereby removing water vapor. The system is encased in concrete to prevent exposure to radioactivity. The use of standard 30 and 55 gallon drums permits an inexpensive compact modular design that is readily disposable, thus eliminating maintenance and radiation build-up problems encountered with conventional evaporation systems.

Black, Roger L. (Idaho Falls, ID)

1981-01-01T23:59:59.000Z

298

Drawing graphs nicely using simulated annealing  

Science Conference Proceedings (OSTI)

The paradigm of simulated annealing is applied to the problem of drawing graphs nicely. Our algorithm deals with general undirected graphs with straight-line edges, and employs several simple criteria for the aesthetic quality of the result. ... Keywords: aesthetics, graph drawing, simulated annealing

Ron Davidson; David Harel

1996-10-01T23:59:59.000Z

299

Wind Tunnel Measurements of the Response of Hot-Wire Liquid Water Content Instruments to Large Droplets  

Science Conference Proceedings (OSTI)

Wet wind tunnel tests were performed on more than 23 cloud liquid water content (LWC) probes and drop spectrometers at the NASA Icing Research Tunnel, with a main objective to characterize their response to large-droplet conditions. As a part of ...

J. W. Strapp; J. Oldenburg; R. Ide; L. Lilie; S. Bacic; Z. Vukovic; M. Oleskiw; D. Miller; E. Emery; G. Leone

2003-06-01T23:59:59.000Z

300

Application of solar energy to the supply of industrial process hot water. Energy reduction and economic analysis report. Aerotherm report TR-76-220. [Can washing at Campbell Soup Company in California  

DOE Green Energy (OSTI)

A discussion is provided of the following aspects of the solar process hot water program: criteria and rationale used in process selection, expected fuel savings to be provided by widespread use of the solar energy system in the industry, and economic evaluation of the system. The design, construction, operation, and evaluation of a solar water heating system for application to the can washing process at the Campbell Soup Company's plant located in Sacramento, California are included.

None

1976-10-14T23:59:59.000Z

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Interim Stabilization Equipment Essential and Support Drawing Plan  

SciTech Connect

The purpose of this document is to list the Interim Stabilization equipment drawings that are classified as Essential or Support drawings. Essential Drawings: Those drawings identified by the facility staff as necessary to directly support the safe operation of the facility or equipment. Support Drawings: Those drawings identified by the facility staff that further describe the design details of structures, systems or components shown on essential drawings.

KOCH, M.R.

1999-10-22T23:59:59.000Z

302

Interim Stabilization Equipment Essential and Support Drawing Plan  

Science Conference Proceedings (OSTI)

The purpose of this document is to list the Interim Stabilization equipment drawings that are classified as Essential or Support drawings. Essential Drawings are those drawings identified by the facility staff as necessary to directly support the safe operation of the facility or equipment. [CHG 2000a]. Support Drawings are those drawings identified by the facility staff that further describe the design details of structures, systems or components shown on essential drawings. [CHG 2000a].

HORNER, T.M.

2000-10-16T23:59:59.000Z

303

Performance and economic evaluation of the seahorse natural gas hot water heater conversion at Fort Stewart. Final report  

SciTech Connect

The Federal government is the largest single energy consumer in the United States with consumption of nearly 1.5 quads/year of energy (10{sup 15} quad = 1015 Btu) and cost valued at nearly $10 billion annually. The US Department of Energy`s (DOE) Federal Energy Management Program (FEMP) supports efforts to reduce energy use and associated expenses in the Federal sector. One such effort, the New Technology Demonstration Program (NTDP) seeks to evaluate new energy -- saving US technologies and secure their more timely adoption by the US government. Pacific Northwest Laboratory (PNL) is one of four DOE laboratories that participate in the New Technologies Demonstration Program, providing technical expertise and equipment to evaluate new, energy-saving technologies being studied under that program. This report provides the results of a field evaluation that PNL conducted for DOE/FEMP with funding support from the US Department of Defense (DoD) Strategic Environmental Research and Development Program (SERDP) to examine the performance of 4 candidate energy-saving technology-a water heater conversion system to convert electrically powered water heaters to natural gas fuel. The unit was installed at a single residence at Fort Stewart, a US Army base in Georgia, and the performance was monitored under the NTDP. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) were Gas Fired Products, developers of the technology; the Public Service Company of North Carolina; Atlanta Gas Light Company; the Army Corps of Engineers; Fort Stewart; and Pacific Northwest Laboratory.

Winiarski, D.W.

1995-12-01T23:59:59.000Z

304

Performance Evaluation of a 4.5 kW (1.3 Refrigeration Tons) Air-Cooled Lithium Bromide/Water Solar Powered (Hot-Water-Fired) Absorption Unit  

Science Conference Proceedings (OSTI)

During the summer months, air-conditioning (cooling) is the single largest use of electricity in both residential and commercial buildings with the major impact on peak electric demand. Improved air-conditioning technology has by far the greatest potential impact on the electric industry compared to any other technology that uses electricity. Thermally activated absorption air-conditioning (absorption chillers) can provide overall peak load reduction and electric grid relief for summer peak demand. This innovative absorption technology is based on integrated rotating heat exchangers to enhance heat and mass transfer resulting in a potential reduction of size, cost, and weight of the "next generation" absorption units. Rotartica Absorption Chiller (RAC) is a 4.5 kW (1.3 refrigeration tons or RT) air-cooled lithium bromide (LiBr)/water unit powered by hot water generated using the solar energy and/or waste heat. Typically LiBr/water absorption chillers are water-cooled units which use a cooling tower to reject heat. Cooling towers require a large amount of space, increase start-up and maintenance costs. However, RAC is an air-cooled absorption chiller (no cooling tower). The purpose of this evaluation is to verify RAC performance by comparing the Coefficient of Performance (COP or ratio of cooling capacity to energy input) and the cooling capacity results with those of the manufacturer. The performance of the RAC was tested at Oak Ridge National Laboratory (ORNL) in a controlled environment at various hot and chilled water flow rates, air handler flow rates, and ambient temperatures. Temperature probes, mass flow meters, rotational speed measuring device, pressure transducers, and a web camera mounted inside the unit were used to monitor the RAC via a web control-based data acquisition system using Automated Logic Controller (ALC). Results showed a COP and cooling capacity of approximately 0.58 and 3.7 kW respectively at 35 C (95 F) design condition for ambient temperature with 40 C (104 F) cooling water temperature. This is in close agreement with the manufacturer data of 0.60 for COP and 3.9 kW for cooling capacity. This study resulted in a complete performance map of RAC which will be used to evaluate the potential benefits of rotating heat exchangers in making the "next-generation" absorption chillers more compact and cost effective without any significant degradation in the performance. In addition, the feasibility of using rotating heat exchangers in other applications will be evaluated.

Zaltash, Abdolreza [ORNL; Petrov, Andrei Y [ORNL; Linkous, Randall Lee [ORNL; Vineyard, Edward Allan [ORNL

2007-01-01T23:59:59.000Z

305

DOE Sponsored College Night Draws Thousands | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sponsored College Night Draws Thousands Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands September 6, 2013 - 12:00pm Addthis DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands College recruiters from the Golden State to the Peach State gathered in a packed arena for the twentieth annual CSRA College Night in Augusta, Georgia. The event is a cooperative effort among Department of Energy

306

DOE Sponsored College Night Draws Thousands | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands September 6, 2013 - 12:00pm Addthis DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands DOE Sponsored College Night Draws Thousands College recruiters from the Golden State to the Peach State gathered in a packed arena for the twentieth annual CSRA College Night in Augusta, Georgia. The event is a cooperative effort among Department of Energy

307

Potential for crop drying with geothermal hot water resources in the western United States: alfalfa, a case study. Report 305-100-02  

DOE Green Energy (OSTI)

Preliminary results of engineering, economic, and geographic analysis of the use of low-temperature geothermal heat for the commercial drying of grains, grasses, fruits, vegetables and livestock products in the United States are reported. Alfalfa (lucerne) dehydration was chosen for detailed process and cost study. Six different geothermal heat exchanger/dryer configurations were examined. A conveyor type that could utilize geothermal hot water for its entire heat requirement proved to be the most economical. A capital cost estimate for an all-geothermal alfalfa dehydration plant near the Heber Known Geothermal Resource Area in the Imperial Valley, California was prepared. The combined cost for heat exchangers and dryer is about $1.6 million. Output is about 11 metric tons per hour. Acreage, production and dollar value data for 22 dryable crops were compiled for the areas surrounding identified hydrothermal resources in 11 western states. The potential magnitude of fossil fuel use that could be replaced by geothermal heat for drying these crops will be estimated.

Wright, T.C.

1977-06-22T23:59:59.000Z

308

Hot Water Electric Energy Use in Single-Family Residences in the Pacific Northwest : Regional End-Use Metering Project (REMP).  

SciTech Connect

The Office of Energy Resources of the Bonneville Power Administration carriers out generation and conservation resource planning. The analysis of historical trends in and determinants of energy consumption is carried out by the office's End-Use Research Section. The End-Use Research Section operates a comprehensive data collection program to provide pertinent information to support demand-side conservation planning, load forecasting, and conservation program development and delivery. Part of this on-going program, commonly known as the End-Use Load and Consumer Assessment Program (ELCAP), was recently renamed the Regional End-Use Metering Project (REMP) to reflect an emphasis on metering rather than analytical activities. REMP is designed to collect electricity usage data through direct monitoring of end-use loads in buildings in the residential and commercial sectors and is conducted for Bonneville by Pacific Northwest Laboratories (Battelle). The detailed summary information in this report is on energy used for water heaters in the residential sector and is based on data collected from September 1985 through December 1990 for 336 of the 499 REMP metered homes. Specific information is provided on annual loads averaged over the years and their variation across residences. Descriptions are given of use as associated with demographic and energy-related characteristics. Summaries are also provided for electricity use by each year, month, and daytype, as well as at peak hot water load and peak system times. This is the second residential report. This report focuses on a specific end use and adds detail to the first report. Subsequent reports are planned on other individual end uses or sets of end uses. 15 refs., 29 figs., 10 tabs.

Taylor, Megan E., Ritland, Keith G., Pratt, R.G.

1991-09-01T23:59:59.000Z

309

Building America Top Innovations Hall of Fame Profile … Tankless Gas Water Heater Performance  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Incorporating tankless water heaters was one Incorporating tankless water heaters was one of many energy-efficiency recommendations Building America's research team IBACOS had for San Antonio builder Imagine Homes. Although tankless gas water heaters should save approximately 33% on hot water heating compared to a conventional storage water heater, actual energy savings vary significantly based on individual draw volume. Above 10 gallons per draw, the efficiency approaches the rated energy factor. The greatest savings occur at a daily use quantity of about 50 gallons. BUILDING AMERICA TOP INNOVATIONS HALL OF FAME PROFILE INNOVATIONS CATEGORY: 1. Advanced Technologies and Practices 1.2 Energy Efficient Components Tankless Gas Water Heater Performance As improved thermal enclosures dramatically reduce heating and cooling loads,

310

NUFO Science Exhibition on Capitol Hill Draws Congressmen, Crowds  

NLE Websites -- All DOE Office Websites (Extended Search)

NUFO Science Exhibition on Capitol Hill Draws Congressmen, Crowds NUFO Science Exhibition on Capitol Hill Draws Congressmen, Crowds Print At the invitation of the House Science and...

311

Solar space and water heating system at Stanford University Central Food Services Building. Final report  

DOE Green Energy (OSTI)

This active hydronic domestic hot water and space heating system was 840 ft/sup 2/ of single-glazed, liquid, flat plate collectors and 1550 gal heat storage tanks. The following are discussed: energy conservation, design philosophy, operation, acceptance testing, performance data, collector selection, bidding, costs, economics, problems, and recommendations. An operation and maintenance manual and as-built drawings are included in appendices. (MHR)

Not Available

1980-05-01T23:59:59.000Z

312

Solar hot water system update  

DOE Green Energy (OSTI)

Brief descriptions are given of the following three systems: (1) thermosyphon system, (2) system with drain-down freeze protection, and (3) system with antifreeze as freeze protection. (MOW)

Levary, A.

1978-01-01T23:59:59.000Z

313

"Hot" for Warm Water Cooling  

NLE Websites -- All DOE Office Websites (Extended Search)

Published 112011 Conference Location Seattle, WA Call Number LBNL-5128E Abstract Liquid cooling is key to reducing energy consumption for this generation of supercomputers and...

314

"Hot" for Warm Water Cooling  

Science Conference Proceedings (OSTI)

Liquid cooling is key to reducing energy consumption for this generation of supercomputers and remains on the roadmap for the foreseeable future. This is because the heat capacity of liquids is orders of magnitude larger than that of air and once heat has been transferred to a liquid, it can be removed from the datacenter efficiently. The transition from air to liquid cooling is an inflection point providing an opportunity to work collectively to set guidelines for facilitating the energy efficiency of liquid-cooled High Performance Computing (HPC) facilities and systems. The vision is to use non-compressor-based cooling, to facilitate heat re-use, and thereby build solutions that are more energy-efficient, less carbon intensive and more cost effective than their air-cooled predecessors. The Energy Efficient HPC Working Group is developing guidelines for warmer liquid-cooling temperatures in order to standardize facility and HPC equipment, and provide more opportunity for reuse of waste heat. This report describes the development of those guidelines.

IBM Corporation; Energy Efficient HPC Working Group; Hewlett Packard Corporation; SGI; Cray Inc.; Intel Corporation; U.S. Army Engineer Research Development Center; Coles, Henry; Ellsworth, Michael; Martinez, David J.; Bailey, Anna-Maria; Banisadr, Farhad; Bates, Natalie; Coghlan, Susan; Cowley, David E.; Dube, Nicholas; Fields, Parks; Greenberg, Steve; Iyengar, Madhusudan; Kulesza, Peter R.; Loncaric, Josip; McCann, Tim; Pautsch, Greg; Patterson, Michael K.; Rivera, Richard G.; Rottman, Greg K.; Sartor, Dale; Tschudi, William; Vinson, Wade; Wescott, Ralph

2011-08-26T23:59:59.000Z

315

"Hot" for Warm Water Cooling  

E-Print Network (OSTI)

liquid cooling, dry cooler, cooling tower 1. INTRODUCTIONsolutions for cooling. Substituting cooling towers,hybrid cooling towers, or dry coolers that provide warmer

Coles, Henry

2012-01-01T23:59:59.000Z

316

Geochemical studies at four northern Nevada hot spring areas. [Kyle Hot Springs, Leach Hot Springs, Buffalo Hot Springs, and Beowave Hot Springs  

DOE Green Energy (OSTI)

Water samples from both hot and cold sources in the hydrologic areas surrounding the hot springs were collected and analyzed. Analyses of major, trace, and radio-element abundances of the water samples and of associated rock samples are presented. From this study it is possible that trace- and major-element abundances and/or ratios may be discerned which are diagnostic as chemical geothermometers, complementing those of silica and alkali elements that are presently used. Brief discussions of mixing calculations, possible new chemical geothermometers, and interelement relationships are also included.

Wollenberg, H.; Bowman, H.; Asaro, F.

1977-08-01T23:59:59.000Z

317

Solar process water heat for the Iris Images Custom Color Photo Lab. Final report  

DOE Green Energy (OSTI)

This is the final technical report of the solar facility locted at Iris Images Custom Photo Laboratory in Mill Valley, California. It was designed to provide 59 percent of the hot water requirements for developing photographic film and domestic hot water use. The design load is to provide 6 gallons of hot water per minute for 8 hours per working day at 100/sup 0/F. It has 640 square feet of flat plate collectors and 360 gallons of hot water storage. The auxiliary back up system is a conventional gas-fired water heater. Freeze protection in this mild climate was originally provided by closed-loop circulation of hot water from the storage tank. Later this was changed to a drain-down system due to a freeze when electrical power failed. This system has been relatively successful with little or no scheduled maintenance. The site and building description, subsystem description, as-built drawings, cost breakdown and analysis, performance analysis, lessons learned, and the operation and maintenance manual are included.

Not Available

1980-03-01T23:59:59.000Z

318

Water Heaters and Hot Water Distribution Systems  

E-Print Network (OSTI)

distribution system, ground-source heat pump and ground heatdistribution systems, ground-source heat pumps and ground

Lutz, Jim

2012-01-01T23:59:59.000Z

319

Water Heaters and Hot Water Distribution Systems  

E-Print Network (OSTI)

the elimination of the standby losses common to gas storageflow rates. Eliminating the standby heat loss results in ais used to account for standby losses. Although storage

Lutz, Jim

2012-01-01T23:59:59.000Z

320

Hydrogeologic investigation of Coso Hot Springs, Inyo County...  

Open Energy Info (EERE)

and springs and other features of hydrologic significance and sampling of waters for chemical analysis; determination of the local Coso Hot Springs and regional groundwater...

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Heat Pump Water Heaters and American Homes: A Good Fit?  

SciTech Connect

Heat pump water heaters (HPWHs) are over twice as energy-efficient as conventional electric resistance water heaters, with the potential to save substantial amounts of electricity. Drawing on analysis conducted for the U.S. Department of Energy's recently-concluded rulemaking on amended standards for water heaters, this paper evaluates key issues that will determine how well, and to what extent, this technology will fit in American homes. The key issues include: 1) equipment cost of HPWHs; 2) cooling of the indoor environment by HPWHs; 3) size and air flow requirements of HPWHs; 4) performance of HPWH under different climate conditions and varying hot water use patterns; and 5) operating cost savings under different electricity prices and hot water use. The paper presents the results of a life-cycle cost analysis of the adoption of HPWHs in a representative sample of American homes, as well as national impact analysis for different market share scenarios. Assuming equipment costs that would result from high production volume, the results show that HPWHs can be cost effective in all regions for most single family homes, especially when the water heater is not installed in a conditioned space. HPWHs are not cost effective for most manufactured home and multi-family installations, due to lower average hot water use and the water heater in the majority of cases being installed in conditioned space, where cooling of the indoor environment and size and air flow requirements of HPWHs increase installation costs.

Franco, Victor; Lekov, Alex; Meyers, Steve; Letschert, Virginie

2010-05-14T23:59:59.000Z

322

TofuDraw : choreographing robot behavior through Digital Painting  

E-Print Network (OSTI)

In this document, TofuDraw is introduced as an expressive robotic character with interfaces that enable children to choreograph robotic behaviors through controlling both physical motion and form. Unique to the TofuDraw ...

Wistort, Ryan Mark

2010-01-01T23:59:59.000Z

323

NEWTON: Green Hot  

NLE Websites -- All DOE Office Websites (Extended Search)

to two different phenomena. The 'red-hot' or 'white-hot' designations are due to black body radiation, which you can read about on-line. The colors of flames are due to ionization...

324

Interim Stabilization Equipment Essential and Support Drawing Plan  

Science Conference Proceedings (OSTI)

This supporting document provides a list of the Essential and Support drawings for the Interim Stabilization project equipment.

KOCH, M.R.

2000-01-14T23:59:59.000Z

325

Interim Stabilization Equipment Essential and Support Drawing Plan  

SciTech Connect

This supporting document provides a list of the Essential and Support drawings for the Interim Stabilization project equipment.

KOCH, M.R.

2000-01-28T23:59:59.000Z

326

Waste Receiving and Processing Facility (WRAP) Drawing List  

SciTech Connect

This supporting document delineates the process of identification, categorization, and/or classification of the WRAP facility drawings used to support facility operations and maintenance. This document provides a listing of those essential or safety related drawings which have been identified to date. All other WRAP facility drawings have been classified as general.

WEIDERT, J.R.

1999-10-25T23:59:59.000Z

327

Children's drawing and telling of sustainability in the home  

Science Conference Proceedings (OSTI)

This paper describes a pilot study about children's perspective on environmental sustainability in the home through the drawing-telling technique. We utilize the drawing-telling technique as described by Susan Wright [6] for interviewing children about ... Keywords: children, drawing and telling method, eco-visualization, home, sustainability

Audrey Desjardins; Ron Wakkary

2011-05-01T23:59:59.000Z

328

Performance Testing Residential Heat Pump Water Heaters under South- and Central-Florida Climate Conditions: Hot, Humid Climate and Warm Ground Water Pose Unusual Operating Environment for Heat Pump Water Heaters  

Science Conference Proceedings (OSTI)

Heat pump water heaters (HPWHs) are known to provide considerable energy savings compared with electric resistance devices in many applications. However, as their performance is climate-dependent, it is important to understand their operation in extreme climates. Southern and Central Florida presents an extreme climate for HPWHs, as the air temperature, humidity, and entering water temperatures are all high nearly year-round. This report examines HPWH performance in the Florida Power & Light ...

2013-09-30T23:59:59.000Z

329

Hot Showers, Fresh Laundry, Clean Dishes | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Hot Showers, Fresh Laundry, Clean Dishes Hot Showers, Fresh Laundry, Clean Dishes Hot Showers, Fresh Laundry, Clean Dishes March 5, 2013 - 11:17am Addthis The GE GeoSpring™ Electric Heat Pump Water Heater is readily integrated into new and existing home designs. Taking up the same footprint as a traditional 50-gallon tank water heater, the Electric Heat Pump Water Heater uses the existing water heater's plumbing and electrical connections. Credit: GE The GE GeoSpring(tm) Electric Heat Pump Water Heater is readily integrated into new and existing home designs. Taking up the same footprint as a traditional 50-gallon tank water heater, the Electric Heat Pump Water Heater uses the existing water heater's plumbing and electrical connections. Credit: GE To introduce this new electric heat pump water heater, GE ran a memorable ad during the 2010 Winter Olympics featuring snow monkeys enjoying a hot soak. Credit: GE

330

Preliminary Modeling, Testing, and Analysis of a Gas Tankless Water Heater: Preprint  

DOE Green Energy (OSTI)

Today's gas tankless water heaters offer significant energy savings over conventional gas storage tank water heaters, but savings depends on the draw pattern. A one-node model incorporating heat exchanger mass is used to address this and other issues. Key model parameters are determined from least-squares regression on short-term data, including burner efficiency, thermal capacitance, and thermal loss coefficient. The calibrated model agrees with data to ~5% on Qgas, with temperature RMS deviation of ~4..deg..C. Efficiency with a standard realistic draw is 71%, compared to 81% predicted from standard energy-factors. Adding a small tank controlled by the tankless heater solves issues of oscillations with solar pre-heat, low-flow and hot-water-delay issues. Future work includes model refinements and developing optimal data protocols for model parameter extraction.

Burch, J.; Hoeschele, M.; Springer, D.; Rudd, A.

2008-05-01T23:59:59.000Z

331

DOE fundamentals handbook: Engineering symbology, prints, and drawings  

Science Conference Proceedings (OSTI)

The Engineering Symbology, Prints, and Drawings Handbook was developed to assist nuclear facility operating contractors in providing operators, maintenance personnel, and technical staff with the necessary fundamentals training to ensure a basic understanding of engineering prints, their use, and their function. The handbook includes information on engineering fluid drawings and prints; piping and instrument drawings; major symbols and conventions; electronic diagrams and schematics; logic circuits and diagrams; and fabrication, construction, and architectural drawings. This information will provide personnel with a foundation for reading, interpreting, and using the engineering prints and drawings that are associated with various DOE nuclear facility operations and maintenance.

Not Available

1993-01-01T23:59:59.000Z

332

DOE fundamentals handbook: Engineering symbology, prints, and drawings. Volume 1  

Science Conference Proceedings (OSTI)

The Engineering Symbology, Prints, and Drawings Handbook was developed to assist nuclear facility operating contractors in providing operators, maintenance personnel, and technical staff with the necessary fundamentals training to ensure a basic understanding of engineering prints, their use, and their function. The handbook includes information on engineering fluid drawings and prints; piping and instrument drawings; major symbols and conventions; electronic diagrams and schematics; logic circuits and diagrams; and fabrication, construction, and architectural drawings. This information will provide personnel with a foundation for reading, interpreting, and using the engineering prints and drawings that are associated with various DOE nuclear facility operations and maintenance.

Not Available

1993-01-01T23:59:59.000Z

333

DOE fundamentals handbook: Engineering symbology, prints, and drawings. Volume 2  

SciTech Connect

The Engineering Symbology, Prints, and Drawings Handbook was developed to assist nuclear facility operating contractors in providing operators, maintenance personnel, and technical staff with the necessary fundamentals training to ensure a basic understanding of engineering prints, their use, and their function. The handbook includes information on engineering fluid drawings and prints; piping and instrument drawings; major symbols and conventions; electronic diagrams and schematics; logic circuits and diagrams; and fabrication, construction, and architectural drawings. This information will provide personnel with a foundation for reading, interpreting, and using the engineering prints and drawings that are associated with various DOE nuclear facility operations and maintenance.

Not Available

1993-01-01T23:59:59.000Z

334

Potential of thermal insulation and solar thermal energy in domestic hot water and space heating and cooling sectors in Lebanon in the period 2010 - 2030.  

E-Print Network (OSTI)

??The potential of thermal insulation and solar thermal energy in domestic water heating, space heating and cooling in residential and commercial buildings Lebanon is studied (more)

Zaatari, Z.A.R.

2012-01-01T23:59:59.000Z

335

Geothermal: Hot Documents Search  

Office of Scientific and Technical Information (OSTI)

GEOTHERMAL TECHNOLOGIES LEGACY COLLECTION - Hot Documents Search Geothermal Technologies Legacy Collection HelpFAQ | Site Map | Contact Us | Admin Log On HomeBasic Search About...

336

Hydrogeologic investigation of Coso Hot Springs, Inyo County, California.  

Open Energy Info (EERE)

Hydrogeologic investigation of Coso Hot Springs, Inyo County, California. Hydrogeologic investigation of Coso Hot Springs, Inyo County, California. Final report October 1977--January 1978 Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Report: Hydrogeologic investigation of Coso Hot Springs, Inyo County, California. Final report October 1977--January 1978 Details Activities (2) Areas (1) Regions (0) Abstract: This investigation included: review of existing geologic, geophysical, and hydrologic information; field examination of geologic rock units and springs and other features of hydrologic significance and sampling of waters for chemical analysis; determination of the local Coso Hot Springs and regional groundwater hydrology, including consideration of recharge, discharge, movement, and water quality; and determination of the

337

Team China Solar Decathlon 2011 Construction Drawings  

NLE Websites -- All DOE Office Websites (Extended Search)

NAME NAME ELEVATION 1 A101 SIM 12 21 31.A2 AREA TAG CENTERLINE CALL OUT TAG SYMBOL LEGEND MARK DESCRIPTION DOOR TAG REFERENCE KEYNOTE TAG STRUCTURAL GRID TAG ELEVATION MARKER REVISION TAG NORTH ARROW ROOM TAG INTERIOR ELEVATION TAG SECTION TAG EXTERIOR ELEVATION TAG WALL TAG SPOT ELEVATION WINDOW TAG SHEET KEYNOTE TAG WINDOW TAG GRAPHIC SCALE VIEW TITLE A101 1 Ref 1 Ref 1 Ref 1 Ref 1 A101 C4 DRAWING BLOCK TITLE 1 1/2" = 1'-0" 101 A101 1 SIM ROOM NAME 150 SF 0 01 ROOM NAME 101 ? 1L 1T 0 3m 1 2 0.5 1 2 3 4 5 6 7 A B C D E 1 2 3 4 5 6 7 A B C D E SHEET TITLE LOT NUMBER: DRAWN BY: CHECKED BY: COPYRIGHT: CLIENT U.S. DEPARTMENT OF ENERGY SOLAR DECATHLON 2011 WWW.SOLARDECATHLON.GOV TEAM NAME: ADDRESS: CONTACT: FANTASTIC ARCHITECTURE CONSULTANTS AMAZING ENGINEERS PERFECT LANDSCAPING SAFETY FIRST CODE CONSULTANTS NONE: PROJECT IS PUBLIC DOMAIN 8/13/2011

338

Nano/Micro Vacuum Triodes Using Glass Fiber Drawing Methods  

Nano/Micro Vacuum Triodes Using Glass Fiber Drawing Methods Note: The technology described above is an early stage opportunity. Licensing rights to this intellectual ...

339

Microstructural Evolution in TWIP Steels during Wire Drawing  

Science Conference Proceedings (OSTI)

The results obtained by wire drawing have been compared with those by uniaxial tension and cold rolling. It has been shown that the evolution of texture and...

340

PL FINAL DESIGN REPORT. VOLUME II. PLANT DRAWINGS  

SciTech Connect

Plant drawings for the final design for the Army Reactor (PL-2) are presented. Two hundred and twenty-eight figures are included. (M.C.G.)

Combustion Engineering, Inc. Nuclear Div., Windsor, Conn.

1961-06-30T23:59:59.000Z

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Japanese Officials Draw on Expertise of National Laboratories...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Draw on Expertise of National Laboratories for Fukushima Plant Cleanup TEPCO officials tour the Hanford site to learn about cleanup technologies that could be used in the cleanup...

342

Storage capacity in hot dry rock reservoirs  

DOE Patents (OSTI)

A method is described for extracting thermal energy, in a cyclic manner, from geologic strata which may be termed hot dry rock. A reservoir comprised of hot fractured rock is established and water or other liquid is passed through the reservoir. The water is heated by the hot rock, recovered from the reservoir, cooled by extraction of heat by means of heat exchange apparatus on the surface, and then re-injected into the reservoir to be heated again. Water is added to the reservoir by means of an injection well and recovered from the reservoir by means of a production well. Water is continuously provided to the reservoir and continuously withdrawn from the reservoir at two different flow rates, a base rate and a peak rate. Increasing water flow from the base rate to the peak rate is accomplished by rapidly decreasing backpressure at the outlet of the production well in order to meet periodic needs for amounts of thermal energy greater than a baseload amount, such as to generate additional electric power to meet peak demands. The rate of flow of water provided to the hot dry rock reservoir is maintained at a value effective to prevent depletion of the liquid inventory of the reservoir. 4 figs.

Brown, D.W.

1997-11-11T23:59:59.000Z

343

Storage capacity in hot dry rock reservoirs  

DOE Patents (OSTI)

A method of extracting thermal energy, in a cyclic manner, from geologic strata which may be termed hot dry rock. A reservoir comprised of hot fractured rock is established and water or other liquid is passed through the reservoir. The water is heated by the hot rock, recovered from the reservoir, cooled by extraction of heat by means of heat exchange apparatus on the surface, and then re-injected into the reservoir to be heated again. Water is added to the reservoir by means of an injection well and recovered from the reservoir by means of a production well. Water is continuously provided to the reservoir and continuously withdrawn from the reservoir at two different flow rates, a base rate and a peak rate. Increasing water flow from the base rate to the peak rate is accomplished by rapidly decreasing backpressure at the outlet of the production well in order to meet periodic needs for amounts of thermal energy greater than a baseload amount, such as to generate additional electric power to meet peak demands. The rate of flow of water provided to the hot dry rock reservoir is maintained at a value effective to prevent depletion of the liquid

Brown, Donald W. (Los Alamos, NM)

1997-01-01T23:59:59.000Z

344

Energy resource alternatives competition. Progress report for the period February 1, 1975--December 31, 1975. [Space heating and cooling, hot water, and electricity for homes, farms, and light industry  

DOE Green Energy (OSTI)

This progress report describes the objectives and results of the intercollegiate Energy Resource Alternatives competition. The one-year program concluded in August 1975, with a final testing program of forty student-built alternative energy projects at the Sandia Laboratories in Albuquerque, New Mexico. The goal of the competition was to design and build prototype hardware which could provide space heating and cooling, hot water, and electricity at a level appropriate to the needs of homes, farms, and light industry. The hardware projects were powered by such nonconventional energy sources as solar energy, wind, biologically produced gas, coal, and ocean waves. The competition rules emphasized design innovation, economic feasibility, practicality, and marketability. (auth)

Matzke, D.J.; Osowski, D.M.; Radtke, M.L.

1976-01-01T23:59:59.000Z

345

Tips: Water Heating | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

2, 2012 - 4:53pm Addthis Keep Your Energy Bills Out of Hot Water. Insulate your water heater to save energy and money, or choose an on-demand hot water heater to save even more....

346

Integrated Geophysical Exploration of a Known Geothermal Resource: Neal Hot  

Open Energy Info (EERE)

Geophysical Exploration of a Known Geothermal Resource: Neal Hot Geophysical Exploration of a Known Geothermal Resource: Neal Hot Springs Jump to: navigation, search OpenEI Reference LibraryAdd to library Book Section: Integrated Geophysical Exploration of a Known Geothermal Resource: Neal Hot Springs Abstract We present integrated geophysical data to characterize a geothermal system at Neal Hot Springs in eastern Oregon. This system is currently being developed for geothermal energy production. The hot springs are in a region of complex and intersecting fault trends associated with two major extensional events, the Oregon-Idaho Graben and the Western Snake River Plain. The intersection of these two fault systems, coupled with high geothermal gradients from thin continental crust produces pathways for surface water and deep geothermal water interactions at Neal Hot Springs.

347

Hubble Space Telescope hot Jupiter Transmission Spectral Survey: detection of water in HAT-P-1b from Wide Field Camera 3 near-infrared spatial scan observations  

E-Print Network (OSTI)

We present Hubble Space Telescope near-infrared transmission spectroscopy of the transiting hot-Jupiter HAT-P-1b. We observed one transit with Wide Field Camera 3 using the G141 low-resolution grism to cover the wavelength range 1.087- 1.678 {\\mu}m. These time series observations were taken with the newly available spatial scan mode that increases the duty cycle by nearly a factor of two, thus improving the resulting photometric precision of the data. We measure a planet-to-star radius ratio of Rp/R*=0.11709+/-0.00038 in the white light curve with the centre of transit occurring at 2456114.345+/-0.000133 (JD). We achieve S/N levels per exposure of 1840 (0.061%) at a resolution of {\\Delta\\lambda}=19.2nm (R~70) in the 1.1173 - 1.6549{\\mu}m spectral region, providing the precision necessary to probe the transmission spectrum of the planet at close to the resolution limit of the instrument. We compute the transmission spectrum using both single target and differential photometry with similar results. The resultan...

Wakeford, H R; Deming, D; Gibson, N P; Fortney, J J; Burrows, A S; Ballester, G; Nikolov, N; Aigrain, S; Henry, G; Knutson, H; Etangs, A Lecavelier des; Pont, F; Showman, A P; Vidal-Madjar, A; Zahnle, K

2013-01-01T23:59:59.000Z

348

Programmable rendering of line drawing from 3D scenes  

Science Conference Proceedings (OSTI)

This article introduces a programmable approach to nonphotorealistic line drawings from 3D models, inspired by programmable shaders in traditional rendering. This approach relies on the assumption generally made in NPR that style attributes (color, thickness, ... Keywords: Line drawing, nonphotorealistic rendering (NPR), style

Stphane Grabli; Emmanuel Turquin; Frdo Durand; Franois X. Sillion

2010-03-01T23:59:59.000Z

349

Japanese Officials Draw on Expertise of National Laboratories for Fukushima  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Japanese Officials Draw on Expertise of National Laboratories for Japanese Officials Draw on Expertise of National Laboratories for Fukushima Plant Cleanup Japanese Officials Draw on Expertise of National Laboratories for Fukushima Plant Cleanup January 30, 2013 - 12:00pm Addthis Japanese Officials Draw on Expertise of National Laboratories for Fukushima Plant Cleanup TEPCO officials tour the Hanford site to learn about cleanup technologies that could be used in the cleanup of the Fukushima Daiichi Nuclear Power Plant accident that occurred in 2011. TEPCO officials tour the Hanford site to learn about cleanup technologies that could be used in the cleanup of the Fukushima Daiichi Nuclear Power Plant accident that occurred in 2011. Japanese Officials Draw on Expertise of National Laboratories for Fukushima Plant Cleanup

350

Water  

NLE Websites -- All DOE Office Websites (Extended Search)

Laws Envirosearch Institutional Controls NEPA Activities RCRA RQ*Calculator Water HSS Logo Water Laws Overview of water-related legislation affecting DOE sites Clean...

351

Instantaneous gas water heater  

SciTech Connect

Hot water supply temperature is set by a temperature setting device in response to an instantaneous flow rate signal from a water flow rate sensor arranged in a water supply pipe and a feeding water temperature signal from a feeding water temperature sensor which are compared with a predetermined hot water supply temperature and calculated in a control unit. A proportional valve and other devices in a gas supply pipe are controlled in response to the result of the comparison and calculation to define a required volume of gas for ignition and heating. At the same time, a fan damper is controlled by a damper control device so as to adjust the volume of combustion air. A signal representing discharging hot water temperature from a discharging hot water temperature sensor arranged in a hot water feeding pipe is fed back to the control unit and calculated therein, and a valve in the hot water supply pipe is adjusted in response to the result of calculation to attain the desired hot water supply temperature. In order to prevent freezing in the system in winter season, a signal from a thermostat in the water feeding pipe is transmitted to a heater arranged in an air supply chamber so as to heat a heat exchanger pipe and, at the same time, heaters arranged in the water feeding pipe and the hot water supply pipe are also controlled to prevent freezing.

Tsutsui, O.; Kuwahara, H.; Murakami, Sh.; Yasunaga, Sh.

1985-02-26T23:59:59.000Z

352

Geothermal resource assessment of Waunita Hot Springs, Colorado  

DOE Green Energy (OSTI)

This assessment includes the project report; the geothermal prospect reconnaissance evaluation and recommendations; interpretation of water sample analyses; a hydrogeochemical comparison of the Waunita Hot Springs, Hortense, Castle Rock, and Anderson Hot Springs; geothermal resistivity resource evaluation survey, the geophysical environment; temperature, heat flow maps, and temperature gradient holes; and soil mercury investigations.

Zacharakis, T.G. (ed.)

1981-01-01T23:59:59.000Z

353

Hot and Cold  

NLE Websites -- All DOE Office Websites (Extended Search)

What happens to neon gas when it gets very hot? In this experiment, liquid nitrogen and Tesla coils are used to study the effects of extreme temperatures on everyday objects. Don't...

354

Reactor hot spot analysis  

SciTech Connect

The principle methods for performing reactor hot spot analysis are reviewed and examined for potential use in the Applied Physics Division. The semistatistical horizontal method is recommended for future work and is now available as an option in the SE2-ANL core thermal hydraulic code. The semistatistical horizontal method is applied to a small LMR to illustrate the calculation of cladding midwall and fuel centerline hot spot temperatures. The example includes a listing of uncertainties, estimates for their magnitudes, computation of hot spot subfactor values and calculation of two sigma temperatures. A review of the uncertainties that affect liquid metal fast reactors is also presented. It was found that hot spot subfactor magnitudes are strongly dependent on the reactor design and therefore reactor specific details must be carefully studied. 13 refs., 1 fig., 5 tabs.

Vilim, R.B.

1985-08-01T23:59:59.000Z

355

Hot Dry Rock - Summary  

SciTech Connect

Hot Dry Rock adds a new flexibility to the utilization of geothermal energy. Almost always the approach has been to limit that utilization to places where there is a natural source of water associated with a source of heat. Actually, the result was that steam was mined. Clearly there are much larger heat resources available which lack natural water to transport that energy to the surface. Also, as is found in hydrothermal fields being mined for steam, the water supply finally gets used up. There is a strong motive in the existing capital investment to revitalize those resources. Techniques for introducing, recovering and utilizing the water necessary to recover the heat from below the surface of the earth is the subject of this session. Implicit in that utilization is the ability to forecast with reasonable accuracy the busbar cost of that energy to the utility industry. The added element of supplying the water introduces costs which must be recovered while still supplying energy which is competitive. Hot Dry Rock technology can supply energy. That has been proved long since. The basic barrier to its use by the utility industry has been and remains proof to the financial interests that the long term cost is competitive enough to warrant investment in a technology that is new to utility on-grid operations. As the opening speaker for this session states, the test that is underway will ''simulate the operations of a commercial facility in some ways, but it will not show that energy from HDR can be produced at a variety of locations with different geological settings''. Further, the Fenton Hill system is a research facility not designed for commercial production purposes, but it can give indications of how the system must be changed to provide economic HDR operations. And so it is that we must look beyond the long term flow test, at the opportunities and challenges. Proving that the huge HDR resources can be accessed on a worldwide scale must involve the construction of additional sites, preferably to the specifications of the now Federal geothermal community. These facilities will have to be engineered to produce and market energy at competitive prices. At the same time, we must not rest on our technological laurels, though they be many. Design and operational techniques have been conceived which could lead to improved economics and operations for HDR. These must be pursued and where merit is found, vigorously pursued. Accelerated research and development ought to include revolutionary drilling techniques, reservoir interrogation, and system modeling to assure the competitiveness and geographical diversity of applications of HDR. Much of this work will be applicable to the geothermal industry in general. More advanced research ought to include such innovations as the utilization of other operating fluids. Supercritical carbon dioxide and the ammonia/water (Kalina) cycle have been mentioned. But even as the near and more distant outlook is examined, today's work was reported in the HDR session. The start-up operations for the current test series at the Fenton Hill HDR Pilot Plant were described. The surface plant is complete and initial operations have begun. While some minor modifications to the system have been required, nothing of consequence has been found to impede operations. Reliability, together with the flexibility and control required for a research system were shown in the system design, and demonstrated by the preliminary results of the plant operations and equipment performance. Fundamental to the overall success of the HDR energy resource utilization is the ability to optimize the pressure/flow impedance/time relationships as the reservoir is worked. Significant new insights are still being developed out of the data which will substantially affect the operational techniques applied to new systems. However, again, these will have to be proved to be general and not solely specific to the Fenton Hill site. Nevertheless, high efficiency use of the reservoir without unintended reservoir grow

Tennyson, George P. Jr.

1992-03-24T23:59:59.000Z

356

Tankless Demand Water Heaters  

Energy.gov (U.S. Department of Energy (DOE))

Demand (tankless or instantaneous) water heaters have heating devices that are activated by the flow of water, so they provide hot water only as needed and without the use of a storage tank. They...

357

President Bush Directs Energy Secretary to Draw Down Strategic...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

by pipeline slowly return, so it is critical that our refineries remain supplied with crude oil. "Last night, President Bush took the historic step of directing me to draw down and...

358

Medieval Islamic and Gothic architectural drawings : masons, craftsmen and architects  

E-Print Network (OSTI)

As medieval designers and craftsmen have left us with no textual evidence of their thinking processes, their drawings offer valuable sources through which their approach to design and construction can be investigated. ...

Etemad Yousefi, Arash

2005-01-01T23:59:59.000Z

359

Generating Semantic Description from Drawings of Scenes with Shadows  

E-Print Network (OSTI)

The research reported here concerns the principles used to automatically generate three-dimensional representations from line drawings of scenes. The computer programs involved look at scenes which consist of polyhedra and ...

Waltz, David L.

360

Norwich University Solar Decathlon 2011 Construction Drawings  

NLE Websites -- All DOE Office Websites (Extended Search)

Delta T90 House explores the interdependency Delta T90 House explores the interdependency between the economy and the built environment by revealing the hidden values and richness of a conservation-based lifestyle. This high-performance home models the future of affordable, energy efficient living in Vermont. NORWICH UNIVERSITY CODES: This project was developed under IBC 2012 and using NEC 2011 Article 690. Date Drawn by CONSULTANT: MATTHEW LUTZ CONSULTANT: EDWIN SCHMECKPEPER NORWICH UNIVERSITY 158 HARMON DR. NORTHFIELD VERMONT 05663 WWW.SOLARDECATHLON.GOV REVISIONS 90 A B C D E 1 2 3 4 5 6 7 AS BUILT 8/9/2013 11:28:13 PM G-001 SET TABLE OF CONTENTS DELTA T90 2012/8/1 Author 2013 NORWICH UNIVERSITY SOLAR DECATHLON SHT NO SHEET NAME P-501 WATER STORAGE DETAILS P-601 SUPPLY LINE DIAGRAMS P-603 SUPPLY PLUMBING ISOMETRICS P-604 WASTE PLUMBING ISOMETRICS

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Water | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

daylighting, passive solar and active solar. They also have an 80 gallon solar hot water heater. | Photo by Dennis Schroeder, National Renewable Energy Laboratory. A guide to...

362

12Pixels: exploring social drawing on mobile phones  

Science Conference Proceedings (OSTI)

In this paper we present the design and development of 12Pixels, a novel interface, application, and social web service that allows people to create and share drawings directly from a regular mobile phone. We detail the release of 12Pixels ... Keywords: 12Pixels, art, cellphone, content creation, creativity, creativity support tools, design, drawing, mobile phone, social web, twelve pixels, user generated content, web applications

Karl D. D. Willis; Ivan Poupyrev

2010-05-01T23:59:59.000Z

363

Geothermometry At Hot Springs Ranch Area (Szybinski, 2006) | Open Energy  

Open Energy Info (EERE)

Hot Springs Ranch Area (Szybinski, 2006) Hot Springs Ranch Area (Szybinski, 2006) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Geothermometry At Hot Springs Ranch Area (Szybinski, 2006) Exploration Activity Details Location Hot Springs Ranch Area Exploration Technique Geothermometry Activity Date Usefulness useful DOE-funding Unknown Notes The brine from the drill holes, hot springs, seepages, and irrigation wells was sampled, as well as water from two nearby creeks, (total of 13 samples) and sent for analysis to Thermochem Inc. For sample locations refer to Figure 35; the geochemical data are presented in Appendix C. Geochemical results indicate the presence of two distinct waters in this group of samples (Tom Powell of Thermochem Inc., personal communication, 2005).

364

Water Data Report: An Annotated Bibliography  

E-Print Network (OSTI)

Towers Dishwashers Evaporative coolers Faucets Food steamers Hot water dispensers Ice machines Landscape irrigation Pre-rinse spray

Dunham Whitehead, Camilla; Melody, Moya

2007-01-01T23:59:59.000Z

365

Hot air drum evaporator. [Patent application  

DOE Patents (OSTI)

An evaporation system for aqueous radioactive waste uses standard 30 and 55 gallon drums. Waste solutions form cascading water sprays as they pass over a number of trays arranged in a vertical stack within a drum. Hot dry air is circulated radially of the drum through the water sprays thereby removing water vapor. The system is encased in concrete to prevent exposure to radioactivity. The use of standard 30 and 55 gallon drums permits an inexpensive compact modular design that is readily disposable, thus eliminating maintenance and radiation build-up problems encountered with conventional evaporation systems.

Black, R.L.

1980-11-12T23:59:59.000Z

366

Hot Cell Window Shielding Analysis Using MCNP  

SciTech Connect

The Idaho National Laboratory Materials and Fuels Complex nuclear facilities are undergoing a documented safety analysis upgrade. In conjunction with the upgrade effort, shielding analysis of the Fuel Conditioning Facility (FCF) hot cell windows has been conducted. This paper describes the shielding analysis methodology. Each 4-ft thick window uses nine glass slabs, an oil film between the slabs, numerous steel plates, and packed lead wool. Operations in the hot cell center on used nuclear fuel (UNF) processing. Prior to the shielding analysis, shield testing with a gamma ray source was conducted, and the windows were found to be very effective gamma shields. Despite these results, because the glass contained significant amounts of lead and little neutron absorbing material, some doubt lingered regarding the effectiveness of the windows in neutron shielding situations, such as during an accidental criticality. MCNP was selected as an analysis tool because it could model complicated geometry, and it could track gamma and neutron radiation. A bounding criticality source was developed based on the composition of the UNF. Additionally, a bounding gamma source was developed based on the fission product content of the UNF. Modeling the windows required field inspections and detailed examination of drawings and material specifications. Consistent with the shield testing results, MCNP results demonstrated that the shielding was very effective with respect to gamma radiation, and in addition, the analysis demonstrated that the shielding was also very effective during an accidental criticality.

Chad L. Pope; Wade W. Scates; J. Todd Taylor

2009-05-01T23:59:59.000Z

367

Water heater heat reclaimer  

SciTech Connect

This invention relates to the conservation of energy in a domestic gas water heater by utilizing the hot exhaust gases in a gas water heater for the preheating of the incoming unheated water into the water heater. The exhaust gases from a domestic gas water heater carry wasted heat and the present invention provides a mean to reclaim part of the wasted heat for the preheating of the incoming unheated water during hot water usage periods. During non hot water usage periods the heat in the exhaust gases is not reclaimed to prevent overheating of the water and also to prevent the formation of water deposit in the preheating assembly or heat reclaimer. During the non hot water usage periods the heat produced in the water heater is normally needed only to maintain the desired water temperature of the stored water in the water tank of the water heater. Due to the rapid heating or recovery rate, the present invention enables the use of a smaller water heater. The use of a smaller water heater reduces the normal heat loss from the stored hot water thereby further reduces energy consumption.

Wie, C.T.

1983-08-09T23:59:59.000Z

368

Side-by-Side Testing of Water Heating Systems: Results from the 2010 - 2011 Evaluation  

DOE Green Energy (OSTI)

The Florida Solar Energy Center (FSEC) continues the testing and evaluation of seven water heating systems operating side-by-side at the HWS laboratory in Cocoa, Florida, and documents results in this report. All systems are submitted to alternating hot water draw schedules (ASHRAE 90.1 and NREL/BA). The most significant system change under the latest testing rotation comes from the evaluation of a new state-of-the-art electric heat pump water heater (HPWH) system. The HPWH water heater has demonstrated that under favorable ambient conditions it can perform very well against the best system evaluated in Phase I (2009-2010) ? the differentially controlled solar flat plate solar system.

Colon, C.; Parker, D.

2013-03-01T23:59:59.000Z

369

DOE National Analytical Management Program Draws Global Interest |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

National Analytical Management Program Draws Global Interest National Analytical Management Program Draws Global Interest DOE National Analytical Management Program Draws Global Interest February 27, 2013 - 12:00pm Addthis Hnin Khaing focuses on her work at WIPP Laboratories near Carlsbad, New Mexico Hnin Khaing focuses on her work at WIPP Laboratories near Carlsbad, New Mexico Corey White works at WIPP Laboratories near Carlsbad, New Mexico Corey White works at WIPP Laboratories near Carlsbad, New Mexico Hnin Khaing focuses on her work at WIPP Laboratories near Carlsbad, New Mexico Corey White works at WIPP Laboratories near Carlsbad, New Mexico CARLSBAD, N.M. - The National Analytical Management Program (NAMP), which coordinates analytical services and capabilities throughout DOE, has garnered global interest. "NAMP is addressing a vital need to attain the most effective use of

370

President Bush Directs Energy Secretary to Draw Down Strategic Petroleum  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Directs Energy Secretary to Draw Down Strategic Directs Energy Secretary to Draw Down Strategic Petroleum Reserve President Bush Directs Energy Secretary to Draw Down Strategic Petroleum Reserve September 3, 2005 - 9:49am Addthis Washington, DC - U.S. Secretary of Energy Samuel W. Bodman today released the following statement regarding President Bush's historic decision to authorize the drawdown and sale of oil from America's Strategic Petroleum Reserve. "We continue to work hard to aggressively address the oil and gasoline supply interruption caused by Hurricane Katrina. Over the past several days we have seen the capacity to ship gasoline by pipeline slowly return, so it is critical that our refineries remain supplied with crude oil. "Last night, President Bush took the historic step of directing me to

371

Tips: Water Heating | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tips: Water Heating Tips: Water Heating Tips: Water Heating May 2, 2012 - 4:53pm Addthis Keep Your Energy Bills Out of Hot Water. Insulate your water heater to save energy and money, or choose an on-demand hot water heater to save even more. Keep Your Energy Bills Out of Hot Water. Insulate your water heater to save energy and money, or choose an on-demand hot water heater to save even more. Water heating is the second largest energy expense in your home. It typically accounts for about 18% of your utility bill. There are four ways to cut your water heating bills: use less hot water, turn down the thermostat on your water heater, insulate your water heater, or buy a new, more efficient model. Water Heating Tips Install aerating, low-flow faucets and showerheads. Repair leaky faucets promptly; a leaky faucet wastes gallons of

372

Tips: Water Heating | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Heating Water Heating Tips: Water Heating May 2, 2012 - 4:53pm Addthis Keep Your Energy Bills Out of Hot Water. Insulate your water heater to save energy and money, or choose an on-demand hot water heater to save even more. Keep Your Energy Bills Out of Hot Water. Insulate your water heater to save energy and money, or choose an on-demand hot water heater to save even more. Water heating is the second largest energy expense in your home. It typically accounts for about 18% of your utility bill. There are four ways to cut your water heating bills: use less hot water, turn down the thermostat on your water heater, insulate your water heater, or buy a new, more efficient model. Water Heating Tips Install aerating, low-flow faucets and showerheads. Repair leaky faucets promptly; a leaky faucet wastes gallons of

373

Preliminary geothermal investigations at Manley Hot Springs, Alaska  

DOE Green Energy (OSTI)

Manley Hot Springs is one of several hot springs which form a belt extending from the Seward Peninsula to east-central Alaska. All of the hot springs are low-temperature, water-dominated geothermal systems, having formed as the result of circulation of meteoric water along deepseated fractures near or within granitic intrusives. Shallow, thermally disturbed ground at Manley Hot Springs constitutes an area of 1.2 km by 0.6 km along the lower slopes of Bean Ridge on the north side of the Tanana Valley. This area includes 32 springs and seeps and one warm (29.1/sup 0/C) well. The hottest springs range in temperature from 61/sup 0/ to 47/sup 0/C and are presently utilized for space heating and irrigation. This study was designed to characterize the geothermal system present at Manley Hot Springs and delineate likely sites for geothermal drilling. Several surveys were conducted over a grid system which included shallow ground temperature, helium soil gas, mercury soil and resistivity surveys. In addition, a reconnaissance ground temperature survey and water chemistry sampling program was undertaken. The preliminary results, including some preliminary water chemistry, show that shallow hydrothermal activity can be delineated by many of the surveys. Three localities are targeted as likely geothermal well sites, and a model is proposed for the geothermal system at Manley Hot Springs.

East, J.

1982-04-01T23:59:59.000Z

374

Residential Hot Water Distribution Systems: Roundtable Session  

NLE Websites -- All DOE Office Websites (Extended Search)

David Springer, Davis Energy Group Bion D. Howard, Building Environmental Science & Technology ABSTRACT Residential building practice currently ignores the losses of energy...

375

Hot Water Distribution System Model Enhancements  

Science Conference Proceedings (OSTI)

This project involves enhancement of the HWSIM distribution system model to more accurately model pipe heat transfer. Recent laboratory testing efforts have indicated that the modeling of radiant heat transfer effects is needed to accurately characterize piping heat loss. An analytical methodology for integrating radiant heat transfer was implemented with HWSIM. Laboratory test data collected in another project was then used to validate the model for a variety of uninsulated and insulated pipe cases (copper, PEX, and CPVC). Results appear favorable, with typical deviations from lab results less than 8%.

Hoeschele, M.; Weitzel, E.

2012-11-01T23:59:59.000Z

376

DOE Solar Decathlon: Hot Water Contest  

NLE Websites -- All DOE Office Websites (Extended Search)

Decathlon 2011 New Zealand team members jumping in celebration. U.S. Department of Energy Solar Decathlon Bookmark and Share - Home About Competition Rules Contests - Architecture...

377

Session: Hot Dry Rock  

DOE Green Energy (OSTI)

This session at the Geothermal Energy Program Review X: Geothermal Energy and the Utility Market consisted of four presentations: ''Hot Dry Rock - Summary'' by George P. Tennyson, Jr.; ''HDR Opportunities and Challenges Beyond the Long Term Flow Test'' by David V. Duchane; ''Start-Up Operations at the Fenton Hill HDR Pilot Plant'' by Raymond F. Ponden; and ''Update on the Long-Term Flow Testing Program'' by Donald W. Brown.

Tennyson, George P. Jr.; Duchane, David V.; Ponden, Raymond F.; Brown, Donald W.

1992-01-01T23:59:59.000Z

378

``Hot particle`` intercomparison dosimetry  

SciTech Connect

Dosimetry measurements of four ``hot particles`` were made at different density thickness values using five different methods. The hot particles had maximum dimensions of 650 {mu}m and maximum beta energies of 0.97, 046, 0.36 and 0.32 MeV. Absorbers were used to obtain the dose at different depths for each dosimeter. Measurements were made using exoelectron dosimeters, an extrapolation chamber, NE extremity tape dosimeters, Eberline RO-2 and RO-2A survey meters, and two sets of GafChromic dye film with each set read out at a different institution. From these results the dose was calculated averaged over 1 cm{sup 2} of tissue at 18, 70, 125, and 400 {mu}m depth. Comparisons of tissue-dose averaged over 1 cm{sup 2} for 18, 70 and 125 {mu}m depth based on interpolated measured values, were within 30% for the GafChromic dye film, extrapolation chamber, NE Extremity Tape dosimeters, and Eberline RO-2 and 2A survey meters except for the hot particle with 0.46 MeV maximum beta energy. The results for this source showed differences of up to 60%. The extrapolation chamber and NE Extremity Tape dosimeters under-responded for measurements at 400 {mu}m by about a factor of 2 compared with the Gaf Chromic dye films for two hot particles with maximum beta energy of 0.32 and 0.36 MeV which each emitted two 100% 1 MeV photons per disintegration. Tissue doses determined using exoelectron dosimeters were a factor of 2 to 5 less than those determined using other dosimeters, possibly due to failures of the equipment.

Kaurin, D.G.L.; Baum, J.W. [Brookhaven National Lab., Upton, NY (United States); Charles, M.W.; Darley, D.P.J. [Birmingham Univ. (United Kingdom); Durham, J.S. [Pacific Northwest Lab., Richland, WA (United States); Scannell, M.J. [Yankee Atomic Electric Co., Bolton, MA (United States); Soares, C.G. [National Inst. of Standards and Technology, Gaithersburg, MD (United States)

1996-06-01T23:59:59.000Z

379

Artificial geothermal reservoirs in hot volcanic rock  

SciTech Connect

S>Some recent results from the Los Alamos program in which hydraulic fracturing is used for the recovery of geothermal energy are discussed. The location is about 4 kilometers west and south of the ring fault of the enormous Jemez Caldera in the northcentral part of New Mexico. It is shown that geothermal energy may be extracted from hot rock that does not contain circulating hot water or steam and is relatively impermeable. A fluid is pumped at high pressure into an isolated section of a wellbore. If the well is cased the pipe in this pressurized region is perforated as it is in the petroleum industry, so that the pressure may be applied to the rock, cracking it. A second well is drilled a few hundred feet away from the first. Cold water is injected through the first pipe, circulates through the crack, and hot water returns to the surface through the second pipe. Results are described and circumstances are discussed under which artiflcial geothermal reservoirs might be created in the basaltic rock of Hawaii. (MCW)

Aamodt, R.L.

1974-02-08T23:59:59.000Z

380

Water-Heating Dehumidifier - Energy Innovation Portal  

Hydrogen and Fuel Cell; Hydropower, Wave and Tidal; Industrial Technologies; Solar ... When the tank of water heater is full of hot water or a ...

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

THE NEGATIVE IMPACT OF COLD WATER...  

NLE Websites -- All DOE Office Websites (Extended Search)

NEGATIVE IMPACT OF COLD WATER BYPASS ON SOLAR DOMESTIC HOT WATER SYSTEMS Final Report DRAFT Prepared for THE NEW YORK STATE ENERGY RESEARCH AND DEVELOPMENT AUTHORITY Albany, NY...

382

Isotopic Analysis- Fluid At Indian Valley Hot Springs Geothermal Area  

Open Energy Info (EERE)

Isotopic Analysis- Fluid At Indian Valley Hot Springs Geothermal Area Isotopic Analysis- Fluid At Indian Valley Hot Springs Geothermal Area (1990) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Isotopic Analysis- Fluid At Indian Valley Hot Springs Geothermal Area (1990) Exploration Activity Details Location Indian Valley Hot Springs Geothermal Area Exploration Technique Isotopic Analysis- Fluid Activity Date 1990 Usefulness not indicated DOE-funding Unknown Exploration Basis Determine the recharge of the area Notes Hydrogen and oxygen isotope data on waters of Coso thermal and nonthermal waters were studied. Hydrogen and oxygen isotopes do not uniquely define the recharge area for the Coso geothermal system but strongly suggest Sierran recharge with perhaps some local recharge. References

383

Kelley Hot Spring Geothermal Project: Kelly Hot Spring Agricultural Center conceptual design  

DOE Green Energy (OSTI)

The proposed core activity in the Kelly Hot Spring Agricultural Center is a nominal 1200 sow swine raising complex. The swine raising is to be a totally confined operation for producing premium pork in controlled environment facilities that utilize geothermal energy. The complex will include a feedmill for producing the various feed formulae required for the animals from breeding through gestation, farrowing, nursery, growing and finishing. The market animals are shipped live by truck to slaughter in Modesto, California. A complete waste management facility will include manure collection from all raising areas, transport via a water flush sysem to methane (biogas) generators, manure separation, settling ponds and disposition of the surplus agricultural quality water. The design is based upon the best commercial practices in confined swine raising in the US today. The most unique feature of the facility is the utilization of geothermal hot water for space heating and process energy throughout the complex.

Longyear, A.B. (ed.)

1980-06-01T23:59:59.000Z

384

Waste and Encapsulation Storage Facility (WESF) Essential and Support Drawing List  

Science Conference Proceedings (OSTI)

The drawings identified in this document will comprise the Waste Encapsulation and Storage Facility essential and support drawing list. This list will replace drawings identified as the ''WESF Essential and support drawing list''. Additionally, this document will follow the applicable requirements of HNF-PRO-242 ''Engineering Drawing Requirements'' and FSP-WESF-001, Section EN-1 ''Documenting Engineering Changes''. An essential drawing is defined as an engineering drawing identified by the facility staff as necessary to directly support the safe operation or maintenance of the facility. A support drawing is defined as a drawing identified by the facility staff that further describes the design details of structures, systems, or components shown on essential drawings or is frequently used by the support staff.

SHANNON, W.R.

1999-08-31T23:59:59.000Z

385

ANALYSIS OF OFF-GRID, OFF-PIPE HOUSING FOR HOT-HUMID AND HOT-ARID CLIMATES  

E-Print Network (OSTI)

This paper investigates the feasibility of off-grid, off-pipe housing in hot-humid and hot-arid climates in the U.S. The study aims to eliminate the need for non-renewable sources of energy and municipal water in residences by using off-grid, off-pipe design approach. To accomplish this, a 2001 International Energy Conservation Code compliant house in Houston, TX and Phoenix, AZ was simulated to determine the base-case energy and water use. Based on the availability of on-site renewable energy and water sources (i.e., solar, wind and biomass and rainfall) in these locations, energy and water efficiency measures were selected in order to reduce the energy and water use to a level that could be met solely by on-site renewable resources. Finally, the sizing of the renewable energy and rainwater harvesting systems was performed to provide for daily needs as well as cumulative needs during the critical periods, in order to achieve complete self sufficiency in terms of energy and water use. The analysis was performed by integrating the results of DOE-2.1e, F-Chart and PV F-Chart programs, and cumulative rainwater supply and water demand analysis. The simulation results demonstrate the differences between the priorities for energy efficiency, water-efficiency and renewable energy measures in hot-humid and hot-arid climates.

Malhotra, M.; Haberl, J.

2008-12-01T23:59:59.000Z

386

Session: Hot Dry Rock  

SciTech Connect

This session at the Geothermal Energy Program Review X: Geothermal Energy and the Utility Market consisted of four presentations: ''Hot Dry Rock - Summary'' by George P. Tennyson, Jr.; ''HDR Opportunities and Challenges Beyond the Long Term Flow Test'' by David V. Duchane; ''Start-Up Operations at the Fenton Hill HDR Pilot Plant'' by Raymond F. Ponden; and ''Update on the Long-Term Flow Testing Program'' by Donald W. Brown.

Tennyson, George P. Jr.; Duchane, David V.; Ponden, Raymond F.; Brown, Donald W.

1992-01-01T23:59:59.000Z

387

Method and apparatus for drawing monocrystalline ribbon from a melt  

DOE Patents (OSTI)

A method and apparatus for drawing a monocrystalline ribbon or web from a melt comprising utilizing a shaping die including at least two elements spaced one from the other each having a portion thereof located below the level of the melt and another portion located above the level of the melt a distance sufficient to form a raised meniscus of melt about the corresponding element.

Ciszek, Theodore F. (Evergreen, CO); Schwuttke, Guenter H. (Poughkeepsie, NY)

1981-11-10T23:59:59.000Z

388

Energy from hot dry rock  

DOE Green Energy (OSTI)

The Hot Dry Rock Geothermal Energy Program is described. The system, operation, results, development program, environmental implications, resource, economics, and future plans are discussed. (MHR)

Hendron, R.H.

1979-01-01T23:59:59.000Z

389

Dmplet Interaction with Hot Surfaces  

Science Conference Proceedings (OSTI)

... served at the NGP Technical Program Manager for ... contains a 10 mW, polarized Helium-Neon laser. ... with Hot Surfaces, NGP Annual Report, 1998. ...

2013-04-15T23:59:59.000Z

390

Integration of the geological/engineering model with production performance for Patrick Draw Field, Wyoming  

SciTech Connect

The NIPER Reservoir Assessment and Characterization Research Program incorporates elements of the near-term, mid-term and long-term objectives of the National Energy Strategy-Advanced Oil Recovery Program. The interdisciplinary NIPER team focuses on barrier island reservoirs, a high priority class of reservoirs, that contains large amounts of remaining oil in place located in mature fields with a high number of shut-in and abandoned wells. The project objectives are to: (1) identify heterogeneities that influence the movement and trapping of reservoir fluids in two examples of shoreline barrier reservoirs (Patrick Draw Field, WY and Bell Creek Field, MT); (2) develop geological and engineering reservoir characterization methods to quantify reservoir architecture and predict mobile oil saturation distribution for application of targeted infill drilling and enhanced oil recovery (EOR) processes; and (3) summarize reservoir and production characteristics of shoreline barrier reservoirs to determine similarities and differences. The major findings of the research include: (1) hydrogeochemical analytical techniques were demonstrated to be an inexpensive reservoir characterization tool that provides information on reservoir architecture and compartmentalization; (2) the formation water salinity in Patrick Draw Field varies widely across the field and can result in a 5 to 12% error in saturation values calculated from wireline logs if the salinity variations and corresponding resistivity values are not accounted for; and (3) an analysis of the enhanced oil recovery (EOR) potential of Patrick Draw Field indicates that CO{sub 2} flooding in the Monell Unit and horizontal drilling in the Arch Unit are potential methods to recover additional oil from the field.

Jackson, S.

1993-03-01T23:59:59.000Z

391

Integration of the geological/engineering model with production performance for Patrick Draw Field, Wyoming  

SciTech Connect

The NIPER Reservoir Assessment and Characterization Research Program incorporates elements of the near-term, mid-term and long-term objectives of the National Energy Strategy-Advanced Oil Recovery Program. The interdisciplinary NIPER team focuses on barrier island reservoirs, a high priority class of reservoirs, that contains large amounts of remaining oil in place located in mature fields with a high number of shut-in and abandoned wells. The project objectives are to: (1) identify heterogeneities that influence the movement and trapping of reservoir fluids in two examples of shoreline barrier reservoirs (Patrick Draw Field, WY and Bell Creek Field, MT); (2) develop geological and engineering reservoir characterization methods to quantify reservoir architecture and predict mobile oil saturation distribution for application of targeted infill drilling and enhanced oil recovery (EOR) processes; and (3) summarize reservoir and production characteristics of shoreline barrier reservoirs to determine similarities and differences. The major findings of the research include: (1) hydrogeochemical analytical techniques were demonstrated to be an inexpensive reservoir characterization tool that provides information on reservoir architecture and compartmentalization; (2) the formation water salinity in Patrick Draw Field varies widely across the field and can result in a 5 to 12% error in saturation values calculated from wireline logs if the salinity variations and corresponding resistivity values are not accounted for; and (3) an analysis of the enhanced oil recovery (EOR) potential of Patrick Draw Field indicates that CO[sub 2] flooding in the Monell Unit and horizontal drilling in the Arch Unit are potential methods to recover additional oil from the field.

Jackson, S.

1993-03-01T23:59:59.000Z

392

Hot Leg Piping Materials Issues  

SciTech Connect

With Naval Reactors (NR) approval of the Naval Reactors Prime Contractor Team (NRPCT) recommendation to develop a gas cooled reactor directly coupled to a Brayton power conversion system as the space nuclear power plant (SNPP) for Project Prometheus (References a and b) the reactor outlet piping was recognized to require a design that utilizes internal insulation (Reference c). The initial pipe design suggested ceramic fiber blanket as the insulation material based on requirements associated with service temperature capability within the expected range, very low thermal conductivity, and low density. Nevertheless, it was not considered to be well suited for internal insulation use because its very high surface area and proclivity for holding adsorbed gases, especially water, would make outgassing a source of contaminant gases in the He-Xe working fluid. Additionally, ceramic fiber blanket insulating materials become very friable after relatively short service periods at working temperatures and small pieces of fiber could be dislodged and contaminate the system. Consequently, alternative insulation materials were sought that would have comparable thermal properties and density but superior structural integrity and greatly reduced outgassing. This letter provides technical information regarding insulation and materials issues for the Hot Leg Piping preconceptual design developed for the Project Prometheus space nuclear power plant (SNPP).

V. Munne

2006-07-19T23:59:59.000Z

393

TRUEX hot demonstration  

SciTech Connect

In FY 1987, a program was initiated to demonstrate technology for recovering transuranic (TRU) elements from defense wastes. This hot demonstration was to be carried out with solution from the dissolution of irradiated fuels. This recovery would be accomplished with both PUREX and TRUEX solvent extraction processes. Work planned for this program included preparation of a shielded-cell facility for the receipt and storage of spent fuel from commercial power reactors, dissolution of this fuel, operation of a PUREX process to produce specific feeds for the TRUEX process, operation of a TRUEX process to remove residual actinide elements from PUREX process raffinates, and processing and disposal of waste and product streams. This report documents the work completed in planning and starting up this program. It is meant to serve as a guide for anyone planning similar demonstrations of TRUEX or other solvent extraction processing in a shielded-cell facility.

Chamberlain, D.B.; Leonard, R.A.; Hoh, J.C.; Gay, E.C.; Kalina, D.G.; Vandegrift, G.F.

1990-04-01T23:59:59.000Z

394

Energy-efficient water heating  

SciTech Connect

This fact sheet describes how to reduce the amount of hot water used in faucets and showers, automatic dishwashers, and washing machines; how to increase water-heating system efficiency by lowering the water heater thermostat, installing a timer and heat traps, and insulating hot water pipes and the storage tank; and how to use off-peak power to heat water. A resource list for further information is included.

NONE

1995-01-01T23:59:59.000Z

395

Geothermometry At Buffalo Valley Hot Springs Area (Laney, 2005) | Open  

Open Energy Info (EERE)

Buffalo Valley Hot Springs Area (Laney, 2005) Buffalo Valley Hot Springs Area (Laney, 2005) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Geothermometry At Buffalo Valley Hot Springs Area (Laney, 2005) Exploration Activity Details Location Buffalo Valley Hot Springs Area Exploration Technique Geothermometry Activity Date Usefulness not indicated DOE-funding Unknown Notes Geochemical Sampling of Thermal and Non-thermal Waters in Nevada, Shevenell and Garside. The objective of this project is to obtain geochemical data from springs (and some wells) for which data are not publicly available, or for which the analyses are incomplete, poor, or nonexistent. With these data, geothermometers are being calculated and a preliminary assessment of the geothermal potential and ranking of the sampled areas is being

396

An Effective Vector Extraction Method on Architectural Imaging Using Drawing Characteristics  

Science Conference Proceedings (OSTI)

In this paper, vectorization is achieved by the recognition of architectural drawing images. To obtain vector components, an architectural drawing recognizer (ADR) is developed. The ADR recognizes line components such as main wall, dimension line and ...

Young-Jun Park; Young-Bin Kwon

2001-09-01T23:59:59.000Z

397

U.S. Scientific Team Draws on New Data, Multiple Scientific Methodolog...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Team Draws on New Data, Multiple Scientific Methodologies to Reach Updated Estimate of Oil Flows from BP's Well U.S. Scientific Team Draws on New Data, Multiple Scientific...

398

Hot Dry Rock Geothermal Energy Development Program  

DOE Green Energy (OSTI)

During Fiscal Year 1987, emphasis in the Hot Dry Rock Geothermal Energy Development Program was on preparations for a Long-Term Flow Test'' of the Phase II'' or Engineering'' hot dry rock energy system at Fenton Hill, New Mexico. A successful 30-day flow test of the system during FY86 indicated that such a system would produce heat at a temperature and rate that could support operation of a commercial electrical power plant. However, it did not answer certain questions basic to the economics of long-term operation, including the rate of depletion of the thermal reservoir, the rate of water loss from the system, and the possibility of operating problems during extended continuous operation. Preparations for a one-year flow test of the system to answer these and more fundamental questions concerning hot dry rock systems were made in FY87: design of the required surface facilities; procurement and installation of some of their components; development and testing of slimline logging tools for use through small-diameter production tubing; research on temperature-sensitive reactive chemical tracers to monitor thermal depletion of the reservoir; and computer simulations of the 30-day test, extended to modeling the planned Long-Term Flow Test. 45 refs., 34 figs., 5 tabs.

Smith, M.C.; Hendron, R.H.; Murphy, H.D.; Wilson, M.G.

1989-12-01T23:59:59.000Z

399

Enhancing naturalness of pen-and-tablet drawing through context sensing  

Science Conference Proceedings (OSTI)

Among artists and designers, the pen-and-tablet combination is widely used for creating digital drawings, as digital pens outperform other input devices in replicating the experience of physical drawing tools. In this paper, we explore how contextual ... Keywords: context sensing, drawing, pen interface

Minghui Sun; Xiang Cao; Hyunyoung Song; Shahram Izadi; Hrvoje Benko; Francois Guimbretiere; Xiangshi Ren; Ken Hinckley

2011-11-01T23:59:59.000Z

400

Re-engineering the Engineering Change Management process for a drawing-less environment  

Science Conference Proceedings (OSTI)

Currently, 3D models and 2D drawings are the main basic elements that together form and carry the product definition throughout the product lifecycle. With the advent of the Digital Product Definition trend, industries have been interested in adopting ... Keywords: Drawing-less, Engineering Change Management (ECM), Engineering drawing, Model-based Definition (MBD), Product lifecycle

Virgilio Quintana; Louis Rivest; Robert Pellerin; Fawzi Kheddouci

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Advanced system demonstration for utilization of biomass as an energy source. Volume IV. Design drawings  

DOE Green Energy (OSTI)

This volume contains design drawings for the biomass cogeneration plant to be built in Maine. The drawings show a considerable degree of detail, however, they are not to be considered released for construction. There has been no actual procurement of equipment, therefore equipment drawings certified by suppliers have not been included. (DMC)

None

1980-10-01T23:59:59.000Z

402

Our Environment in Hot Water: Comparing Water Heaters, A Life...  

NLE Websites -- All DOE Office Websites (Extended Search)

Group Electricity Markets and Policy Group Energy Efficiency Standards Group Indoor Environment Group International Energy Studies Group Sustainable Energy Systems Group Energy...

403

Geothermal Exploration in Hot Springs, Montana  

SciTech Connect

The project involves drilling deeper in the Camp Aqua well dri lled in June 1982 as part of an effort to develop an ethanol plant. The purpose of the current drill ing effort is to determine if water at or above 165???????????????????????????????°F exists for the use in low temperature resource power generation. Previous geothermal resource study efforts in and around Hot Springs , MT and the Camp Aqua area (NE of Hot Springs) have been conducted through the years. A confined gravel aquifer exists in deep alluvium overlain by approximately 250???????????????¢???????????????????????????????? of si lt and c lay deposits from Glacial Lake Missoula. This gravel aquifer overlies a deeper bedrock aquifer. In the Camp Aqua area several wel l s exist in the gravel aquifer which receives hot water f rom bedrock fractures beneath the area. Prior to this exploration, one known well in the Camp Aqua area penetrated into the bedrock without success in intersecting fractures transporting hot geothermal water. The exploration associated with this project adds to the physical knowledge database of the Camp Aqua area. The dri l l ing effort provides additional subsurface information that can be used to gain a better understanding of the bedrock formation that i s leaking hot geothermal water into an otherwise cold water aquifer. The exi s t ing well used for the explorat ion is located within the ???????????????¢????????????????????????????????center???????????????¢??????????????????????????????? of the hottest water within the gravel aquifer. This lent i t sel f as a logical and economical location to continue the exploration within the existing well. Faced with budget constraints due to unanticipated costs, changing dril l ing techniques stretched the limited project resources to maximize the overa l l well depth which f e l l short of original project goals. The project goal of finding 165???????????????????????????????°F or hotter water was not achieved; however the project provides additional information and understanding of the Camp Aqua area that could prove valuable in future exploration efforts

Toby McIntosh, Jackola Engineering

2012-09-26T23:59:59.000Z

404

Hot Hydrogen Test Facility  

DOE Green Energy (OSTI)

The core in a nuclear thermal rocket will operate at high temperatures and in hydrogen. One of the important parameters in evaluating the performance of a nuclear thermal rocket is specific impulse, ISp. This quantity is proportional to the square root of the propellants absolute temperature and inversely proportional to square root of its molecular weight. Therefore, high temperature hydrogen is a favored propellant of nuclear thermal rocket designers. Previous work has shown that one of the life-limiting phenomena for thermal rocket nuclear cores is mass loss of fuel to flowing hydrogen at high temperatures. The hot hydrogen test facility located at the Idaho National Lab (INL) is designed to test suitability of different core materials in 2500C hydrogen flowing at 1500 liters per minute. The facility is intended to test non-uranium containing materials and therefore is particularly suited for testing potential cladding and coating materials. In this first installment the facility is described. Automated Data acquisition, flow and temperature control, vessel compatibility with various core geometries and overall capabilities are discussed.

W. David Swank

2007-02-01T23:59:59.000Z

405

Line Heat-Source Guarded Hot Plate  

Science Conference Proceedings (OSTI)

Line Heat-Source Guarded Hot Plate. Description: The 1-meter guarded hot-plate apparatus measures thermal conductivity of building insulation. ...

2012-03-06T23:59:59.000Z

406

Section 6.1 Water Management: Greening Federal Facilities; Second...  

NLE Websites -- All DOE Office Websites (Extended Search)

resources, reduces the amount of energy and chemicals used for water and wastewater treatment, and, to the extent that the use of hot water is reduced, increases energy...

407

GeoSprings Hybrid Water Heater - Energy Innovation Portal  

The GeoSpring Hybrid Water Heater creates the same amount of hot water as a traditional electric ... Hydrogen and Fuel Cell; Hydropower, Wave and ...

408

Water and Energy Wasted During Residential Shower Events: Findings...  

NLE Websites -- All DOE Office Websites (Extended Search)

Water and Energy Wasted During Residential Shower Events: Findings from a Pilot Field Study of Hot Water Distribution Systems Speaker(s): James Lutz Date: October 18, 2011 -...

409

Water and Energy Wasted During Residential Shower Events: Findings...  

NLE Websites -- All DOE Office Websites (Extended Search)

Wasted During Residential Shower Events: Findings from a Pilot Field Study of Hot Water Distribution Systems Title Water and Energy Wasted During Residential Shower Events:...

410

616 Nonradioactive Dangerous Waste Storage Facility -- Essential/support drawing list. Revision 2  

SciTech Connect

This document identifies the essential and supporting engineering drawings for the 616 Nonradioactive Dangerous Waste Storage Facility. The purpose of the documents is to describe the criteria used to identify and the plan for updating and maintaining their accuracy. Drawings are designated as essential if they relate to safety systems, environmental monitoring systems, effluents, and facility HVAC, electrical, and plumbing systems. Support drawings are those which are frequently used or describe a greater level of detail for equipment, components, or systems shown on essential drawings. A listing of drawings identified as essential or support is provided in Table A.

Busching, K.R.

1994-09-29T23:59:59.000Z

411

Hot Beverages Cold Beverages  

E-Print Network (OSTI)

Juices $3.19 Vitamin Water $1.79 Java Tree Iced Coffee $2.59 Milk, 2% or Low Fat $1.39 20 oz. Coke $4.99 Chicken Caesar Wrap $4.99 Buffalo Chicken Wrap $4.99 Hummus and Vegetables $4.99 Steak &Cheese

New Hampshire, University of

412

The decay of hot nuclei  

Science Conference Proceedings (OSTI)

The formation of hot compound nuclei in intermediate-energy heavy ion reactions is discussed. The statistical decay of such compound nuclei is responsible for the abundant emission of complex fragments and high energy gamma rays. 43 refs., 23 figs.

Moretto, L.G.; Wozniak, G.J.

1988-11-01T23:59:59.000Z

413

Estimation and reduction of the uncertainties in chemical models: Application to hot core chemistry  

E-Print Network (OSTI)

It is not common to consider the role of uncertainties in the rate coefficients used in interstellar gas-phase chemical models. In this paper, we report a new method to determine both the uncertainties in calculated molecular abundances and their sensitivities to underlying uncertainties in the kinetic data utilized. The method is used in hot core models to determine if previous analyses of the age and the applicable cosmic-ray ionization rate are valid. We conclude that for young hot cores ($\\le 10^4$ yr), the modeling uncertainties related to rate coefficients are reasonable so that comparisons with observations make sense. On the contrary, the modeling of older hot cores is characterized by strong uncertainties for some of the important species. In both cases, it is crucial to take into account these uncertainties to draw conclusions from the comparison of observations with chemical models.

Wakelam, V; Herbst, E; Caselli, P; Wakelam, Valentine; Selsis, Franck; Herbst, Eric; Caselli, Paola

2005-01-01T23:59:59.000Z

414

Estimation and reduction of the uncertainties in chemical models: Application to hot core chemistry  

E-Print Network (OSTI)

It is not common to consider the role of uncertainties in the rate coefficients used in interstellar gas-phase chemical models. In this paper, we report a new method to determine both the uncertainties in calculated molecular abundances and their sensitivities to underlying uncertainties in the kinetic data utilized. The method is used in hot core models to determine if previous analyses of the age and the applicable cosmic-ray ionization rate are valid. We conclude that for young hot cores ($\\le 10^4$ yr), the modeling uncertainties related to rate coefficients are reasonable so that comparisons with observations make sense. On the contrary, the modeling of older hot cores is characterized by strong uncertainties for some of the important species. In both cases, it is crucial to take into account these uncertainties to draw conclusions from the comparison of observations with chemical models.

Valentine Wakelam; Franck Selsis; Eric Herbst; Paola Caselli

2005-09-07T23:59:59.000Z

415

Los Alamos hot dry rock geothermal project  

DOE Green Energy (OSTI)

The greatest potential for geothermal energy is the almost unlimited energy contained in the vast regions of hot, but essentially impermeable, rock within the first six or seven km of the Earth's crust. For the past five years, the Los Alamos Scientific Laboratory has been investigating and developing a practical, economical and environmentally acceptable method of extracting this energy. By early 1978, a 10 MW (thermal) heat extraction experiment will be in operation. In the Los Alamos concept, a man-made geothermal reservoir is formed by drilling into a region of suitably hot rock, and then creating within the rock a very large surface for heat transfer by large-scale hydraulic-fracturing techniques. After a circulation loop is formed by drilling a second hole to intersect the fractured region, the heat contained in this reservoir is brought to the surface by the buoyant closed-loop circulation of water. The water is kept liquid throughout the loop by pressurization, thereby increasing the rate of heat transport up the withdrawal hole compared to that possible with steam.

Brown, D.W.; Pettitt, R.A.

1977-01-01T23:59:59.000Z

416

Development of hot dry rock resources  

DOE Green Energy (OSTI)

The LASL Hot Dry Rock Geothermal Energy Project is the only U.S. field test of this geothermal resource. In the LASL concept, a man-made geothermal reservoir would be formed by drilling a deep hole into relatively impermeable hot rock, creating a large surface area for heat transfer by fracturing the rock hydraulically, then drilling a second hole to intersect the fracture to complete the circulation loop. In 1974, the first hole was drilled to a depth of 2929 m (9610 ft) and a hydraulic fracture was produced near the bottom. In 1975, a second hole was directionally drilled to intersect the fracture. Although the desired intersection was not achieved, a connection was made through which water was circulated. After a year's study of the fracture system, drilling began again in April 1977 and an improved connection was achieved. In September of 1977 a 5 MW (thermal) heat extraction and circulation experiment was conducted for 100 h as a preliminary test of the concept. An 1800-h circulation experiment was concluded on April 13, 1978 to determine temperature-drawdown, permeation water loss and flow characteristics of the pressurized reservoir, to examine chemistry changes in the circulating fluid, and to monitor for induced seismic effects.

Pettitt, R.A.; Tester, J.W.

1978-01-01T23:59:59.000Z

417

Industrial applications of hot dry rock geothermal energy  

DOE Green Energy (OSTI)

Geothermal resources in the form of naturally occurring hot water or steam have been utilized for many years. While these hydrothermal resources are found in many places, the general case is that the rock at depth is hot, but does not contain significant amounts of mobile fluid. An extremely large amount of geothermal energy is found around the world in this hot dry rock (HDR). Technology has been under development for more than twenty years at the Los Alamos National Laboratory in the United States and elsewhere to develop the technology to extract the geothermal energy from HDR in a form useful for electricity generation, space heating, or industrial processing. HDR technology is especially attractive for industrial applications because of the ubiquitous distribution of the HDR resource and the unique aspects of the process developed to recover it. In the HDR process, as developed at Los Alamos, water is pumped down a well under high pressure to open up natural joints in hot rock and create an artificial geothermal reservoir. Energy is extracted by circulating water through the reservoir. Pressurized hot water is returned to the surface through the production well, and its thermal energy is extracted for practical use. The same water is then recirculated through the system to mine more geothermal heat. Construction of a pilot HDR facility at Fenton Hill, NM, USA, has recently been completed by the Los Alamos National Laboratory. It consists of a large underground reservoir, a surface plant, and the connecting wellbores. This paper describes HDR technology and the current status of the development program. Novel industrial applications of geothermal energy based on the unique characteristics of the HDR energy extraction process are discussed.

Duchane, D.V.

1992-09-01T23:59:59.000Z

418

Industrial applications of hot dry rock geothermal energy  

DOE Green Energy (OSTI)

Geothermal resources in the form of naturally occurring hot water or steam have been utilized for many years. While these hydrothermal resources are found in many places, the general case is that the rock at depth is hot, but does not contain significant amounts of mobile fluid. An extremely large amount of geothermal energy is found around the world in this hot dry rock (HDR). Technology has been under development for more than twenty years at the Los Alamos National Laboratory in the United States and elsewhere to develop the technology to extract the geothermal energy from HDR in a form useful for electricity generation, space heating, or industrial processing. HDR technology is especially attractive for industrial applications because of the ubiquitous distribution of the HDR resource and the unique aspects of the process developed to recover it. In the HDR process, as developed at Los Alamos, water is pumped down a well under high pressure to open up natural joints in hot rock and create an artificial geothermal reservoir. Energy is extracted by circulating water through the reservoir. Pressurized hot water is returned to the surface through the production well, and its thermal energy is extracted for practical use. The same water is then recirculated through the system to mine more geothermal heat. Construction of a pilot HDR facility at Fenton Hill, NM, USA, has recently been completed by the Los Alamos National Laboratory. It consists of a large underground reservoir, a surface plant, and the connecting wellbores. This paper describes HDR technology and the current status of the development program. Novel industrial applications of geothermal energy based on the unique characteristics of the HDR energy extraction process are discussed.

Duchane, D.V.

1992-01-01T23:59:59.000Z

419

Exploration Of The Upper Hot Creek Ranch Geothermal Resource, Nye County,  

Open Energy Info (EERE)

Of The Upper Hot Creek Ranch Geothermal Resource, Nye County, Of The Upper Hot Creek Ranch Geothermal Resource, Nye County, Nevada Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Report: Exploration Of The Upper Hot Creek Ranch Geothermal Resource, Nye County, Nevada Details Activities (2) Areas (1) Regions (0) Abstract: The Upper Hot Creek Ranch (UHCR) geothermal system had seen no significant exploration activity prior to initiation of this GRED III project. Geochemical geothermometers calculated from previously available but questionable quality analyses of the UHCR hot spring waters indicated possible subsurface temperatures of +320 oF. A complex Quaternary and Holocene faulting pattern associated with a six mile step over of the Hot Creek Range near the UHCR also indicated that this area was worthy of some

420

Thermal Gradient Holes At Spencer Hot Springs Area (Shevenell, Et Al.,  

Open Energy Info (EERE)

Hot Springs Area (Shevenell, Et Al., Hot Springs Area (Shevenell, Et Al., 2008) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Thermal Gradient Holes At Spencer Hot Springs Area (Shevenell, Et Al., 2008) Exploration Activity Details Location Spencer Hot Springs Area Exploration Technique Thermal Gradient Holes Activity Date Usefulness useful DOE-funding Unknown Notes Collaboration with the gold mining industry has brought two new geothermal discoveries to the attention of the geothermal community. Exploration holes at Tungsten Mountain and McGuiness Hills (Spencer Hot Springs?) in 2004 and 2005 encountered hot water and steam at depths of meters with fluid geothermometry indicating reservoir temperatures of 170 to 200oC. More information can be obtained from the Nevada Bureau of Mines and Geology web

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Self Potential At Mt Princeton Hot Springs Area (Richards, Et Al., 2010) |  

Open Energy Info (EERE)

Self Potential At Mt Princeton Hot Springs Area (Richards, Et Al., 2010) Self Potential At Mt Princeton Hot Springs Area (Richards, Et Al., 2010) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Self Potential At Mt Princeton Hot Springs Area (Richards, Et Al., 2010) Exploration Activity Details Location Mt Princeton Hot Springs Area Exploration Technique Self Potential Activity Date Usefulness useful DOE-funding Unknown Notes Used to map fracture and fluid flow patterns. References K. Richards, A. Revil, A. Jardani, F. Henderson, M. Batzle, A. Haas (2010) Pattern Of Shallow Ground Water Flow At Mount Princeton Hot Springs, Colorado, Using Geoelectrical Methods Retrieved from "http://en.openei.org/w/index.php?title=Self_Potential_At_Mt_Princeton_Hot_Springs_Area_(Richards,_Et_Al.,_2010)&oldid=388680"

422

Solar water heater lease program. Interim report  

SciTech Connect

The Solar Water Heater Lease Program consists of the installation and leasing of ten solar systems to central Illinois homeowners. The measured energy savings to the homeowners and the impact of such systems on energy production requirements are studied. Each homeowner collects data on the gallons of hot water used, electricity used to heat water, and the temperatures of the cold and hot water outlet temperatures at the sink. The data are presented and conclusions are drawn, including the optimum slope of the collector, comparison of the actual hot water consumption and the estimated consumption, evaluation of the effects of temperature settings of the non-solar water heater, and the percentage of the energy provided for hot water by the solar system. The monitoring procedures and results are evaluated. Recommendations for improving the solar hot water systems are presented. (LEW)

1982-01-01T23:59:59.000Z

423

The Hot Deformation Behavior of an As-Cast Alloy 718 Ingot  

Science Conference Proceedings (OSTI)

The data suggest that hot working in the temperature range of .... 12.5% distilled water, 10% ... The stress-strain curves for samples deformed at 950C exhibited.

424

Tribology and Tool Wear of Hot Dip Galvanized Zinc Magnesium Alloys on Cold Rolled Steel Sheets  

SciTech Connect

Recently zinc based coatings on cold rolled steel with improved functionality in terms of forming and/or corrosion behaviour have been intensively investigated in the steel industry. One of the most promising products are zinc magnesium alloys produced in hot dip galvanizing process. These coatings were already introduced in construction industry a few years ago. With some modifications the improved properties of the coating are also interesting for automotive industry. In the present work the tribological potential of hot dip galvanized zinc magnesium coatings (HDG/ZM) produced at an industrial line under regular production, was studied in terms of sliding properties, adhesive and abrasive tool wear.First a short introduction into surface morphology of HDG/ZM will be given. For the tribological characterization of the material, which is the main topic of the contribution, different tests were performed on hot dip galvanised zinc magnesium material and results were compared with classic hot dip galvanized zinc coating (HDG/Z). The investigations are mainly based on the strip draw test which allows the determination of the friction coefficient directly by using a constant contact pressure. Deep drawing property was tested by forming model cups. The abrasive tool wear was tested using a standard test for material used in automotive industry. The adhesive tool wear was investigated by characterizing the coating material transferred to the tool in the strip draw test.All performed tests show an improved drawability of HDG/ZM compared to classical HDG/Z reference material. However the most promising difference between HDG/ZM and HDG/Z is that galling was found to be less for HDG/ZM than for HDG/Z. Therefore HDG/ZM is an interesting system not only with respect to corrosion protection but also in terms of tribology and provides clear advantages in formability.

Raab, A. E.; Berger, E.; Freudenthaler, J.; Leomann, F.; Walch, C. [Research and Development, Forming Technology voestalpine Stahl GmbH, Voest-Alpine Strasse 3, 4031 Linz (Austria)

2011-05-04T23:59:59.000Z

425

Thermal Gradient Holes At Hot Springs Ranch Area (Szybinski, 2006) | Open  

Open Energy Info (EERE)

Thermal Gradient Holes At Hot Springs Ranch Area (Szybinski, 2006) Thermal Gradient Holes At Hot Springs Ranch Area (Szybinski, 2006) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Thermal Gradient Holes At Hot Springs Ranch Area (Szybinski, 2006) Exploration Activity Details Location Hot Springs Ranch Area Exploration Technique Thermal Gradient Holes Activity Date Usefulness useful DOE-funding Unknown Notes In 2005, Nevada Geothermal Power Company drilled four geothermal gradient wells, PVTG-1, -2, -3, and -4, and all four encountered geothermal fluids. The holes provided valuable water geochemistry, supporting the geothermometry results obtained from the hot springs and Magma well. The temperature data gathered from all the wells clearly indicates the presence of a major plume of thermal water centered on the Pumpernickel Valley

426

The Nevzorov Airborne Hot-Wire LWCTWC Probe: Principle of Operation and Performance Characteristics  

Science Conference Proceedings (OSTI)

The Nevzorov liquid water content (LWC) and total water content (TWC) probe is a constant-temperature, hot-wire probe designed for aircraft measurements of the ice and liquid water content of clouds. The probe consists of two separate sensors for ...

A. V. Korolev; J. W. Strapp; G. A. Isaac; A. N. Nevzorov

1998-12-01T23:59:59.000Z

427

Promethus Hot Leg Piping Concept  

SciTech Connect

The Naval Reactors Prime Contractor Team (NRPCT) recommended the development of a gas cooled reactor directly coupled to a Brayton energy conversion system as the Space Nuclear Power Plant (SNPP) for NASA's Project Prometheus. The section of piping between the reactor outlet and turbine inlet, designated as the hot leg piping, required unique design features to allow the use of a nickel superalloy rather than a refractory metal as the pressure boundary. The NRPCT evaluated a variety of hot leg piping concepts for performance relative to SNPP system parameters, manufacturability, material considerations, and comparison to past high temperature gas reactor (HTGR) practice. Manufacturability challenges and the impact of pressure drop and turbine entrance temperature reduction on cycle efficiency were discriminators between the piping concepts. This paper summarizes the NRPCT hot leg piping evaluation, presents the concept recommended, and summarizes developmental issues for the recommended concept.

AM Girbik; PA Dilorenzo

2006-01-24T23:59:59.000Z

428

Hot conditioning equipment conceptual design report  

SciTech Connect

This report documents the conceptual design of the Hot Conditioning System Equipment. The Hot conditioning System will consist of two separate designs: the Hot Conditioning System Equipment; and the Hot Conditioning System Annex. The Hot Conditioning System Equipment Design includes the equipment such as ovens, vacuum pumps, inert gas delivery systems, etc.necessary to condition spent nuclear fuel currently in storage in the K Basins of the Hanford Site. The Hot Conditioning System Annex consists of the facility of house the Hot Conditioning System. The Hot Conditioning System will be housed in an annex to the Canister Storage Building. The Hot Conditioning System will consist of pits in the floor which contain ovens in which the spent nuclear will be conditioned prior to interim storage.

Bradshaw, F.W., Westinghouse Hanford

1996-08-06T23:59:59.000Z

429

Hot Gas Halos in Galaxies  

Science Conference Proceedings (OSTI)

We use Chandra and XMM-Newton to study how the hot gas content in early-type galaxies varies with environment. We find that the L{sub X}-L{sub K} relationship is steeper for field galaxies than for comparable galaxies in groups and clusters. This suggests that internal processes such as supernovae driven winds or AGN feedback may expel hot gas from low mass field galaxies. Such mechanisms are less effective in groups and clusters where the presence of an intragroup or intracluster medium may confine outflowing material.

Mulchaey, John S. [Carnegie Observatories (United States); Jeltema, Tesla E. [UCO/Lick Observatories (United States)

2010-06-08T23:59:59.000Z

430

Hot dry rock geothermal heat extraction  

DOE Green Energy (OSTI)

A man-made geothermal reservoir has been created at a depth of 2.7 km in hot, dry granite by hydraulic fracturing. The system was completed by directionally drilling a second well in close proximity with the top of the vertical fracture. In early 1978 heat was extracted from this reservoir for a period of 75 days. During this period thermal power was produced at an average rate of 4 MW(t). Theoretical analysis of th measured drawdown suggests a total fracture heat transfer area of 16,000 m/sup 2/. Viscous impedance to through-flow declined continuously so that at the end of the experiment this impedance was only one-fifth its initial value. Water losses to the surrounding rock formation also decreased continuously, and eventually this loss rate was less than 1% of the circulated flow rate. Geochemical analyses suggest that, with scale up of the heat transfer area and deeper, hotter reservoirs, hot dry rock reservoirs can ultimately produce levels of power on a commercial scale.

Murphy, H.D.

1979-01-01T23:59:59.000Z

431

Compound and Elemental Analysis At Hot Springs Ranch Area (Szybinski, 2006)  

Open Energy Info (EERE)

Compound and Elemental Analysis At Hot Springs Ranch Compound and Elemental Analysis At Hot Springs Ranch Area (Szybinski, 2006) Exploration Activity Details Location Hot Springs Ranch Area Exploration Technique Compound and Elemental Analysis Activity Date Usefulness useful DOE-funding Unknown Notes The brine from the drill holes, hot springs, seepages, and irrigation wells was sampled, as well as water from two nearby creeks, (total of 13 samples) and sent for analysis to Thermochem Inc. For sample locations refer to Figure 35; the geochemical data are presented in Appendix C. Geochemical results indicate the presence of two distinct waters in this group of samples (Tom Powell of Thermochem Inc., personal communication, 2005). Powell found that MDH, TRS-1 and TRS-6 are the most prospective waters and tend to be more bicarbonate rich with much higher proportions of B, Li and

432

Enviropower hot gas desulfurization pilot  

SciTech Connect

The objectives of the project are to develop and demonstrate (1) hydrogen sulfide removal using regenerable zinc titanate sorbent in pressurized fluidized bed reactors, (2) recovery of the elemental sulfur from the tail-gas of the sorbent regenerator and (3) hot gas particulate removal system using ceramic candle filters. Results are presented on pilot plant design and testing and modeling efforts.

Ghazanfari, R.; Feher, G.; Konttinen, J.; Ghazanfari, R.; Lehtovaara, A.; Mojtahedi, W.

1994-11-01T23:59:59.000Z

433

Energy extraction characteristics of hot dry rock geothermal systems  

DOE Green Energy (OSTI)

The LASL Hot Dry Rock Geothermal Energy Project is investigating methods to extract energy at useful temperatures and rates from naturally heated crustal rock in locations where the rock does not spontaneously yield natural steam or hot water at a rate sufficient to support commercial utilization. Several concepts are discussed for application to low and high permeability formations. The method being investigated first is intended for use in formations of low initial permeability. It involves producing a circulation system within the hot rock by hydraulic fracturing to create a large crack connecting two drilled holes, then operating the system as a closed pressurized-water heat-extration loop. With the best input assumptions that present knowledge provides, the fluid-flow and heat-exchange calculations indicate that unpumped (buoyant) circulation through a large hydraulic fracture can maintain a commercially useful rate of heat extraction throughout a usefully long system life. With a power cycle designed for the temperature of the fluid produced, total capital investment and generating costs are estimated to be at least competitive with those of fossil-fuel-fired and nuclear electric plants. This paper discusses the potential of the hot dry rock resource, various heat extraction concepts, prediction of reservoir performance, and economic factors, and summarizes recent progress in the LASL field program.

Tester, J.W.; Smith, M.C.

1977-01-01T23:59:59.000Z

434

Hot Dry Rock Overview at Los Alamos  

DOE Green Energy (OSTI)

The Hot Dry Rock (HDR) geothermal energy program is a renewable energy program that can contribute significantly to the nation's balanced and diversified energy mix. Having extracted energy from the first Fenton Hill HDR reservoir for about 400 days, and from the second reservoir for 30 days in a preliminary test, Los Alamos is focusing on the Long Term Flow Test and reservoir studies. Current budget limitations have slowed preparations thus delaying the start date of that test. The test is planned to gather data for more definitive reservoir modeling with energy availability or reservoir lifetime of primary interest. Other salient information will address geochemistry and tracer studies, microseismic response, water requirements and flow impedance which relates directly to pumping power requirements. During this year of ''preparation'' we have made progress in modeling studies, in chemically reactive tracer techniques, in improvements in acoustic or microseismic event analysis.

Berger, Michael; Hendron, Robert H.

1989-03-21T23:59:59.000Z

435

An Economic Analysis of Erosion and Sediment Damage in the Lower Running Draw Watershed  

E-Print Network (OSTI)

The development and implementation of agricultural non-point source (NPS) pollution control plans was mandated by the 1972 Federal Pollution Control Act Amendments, Public Law 92-500. The purpose of this particular report is to present the results of a study on the economic impact of implementing potential agricultural NPS pollution controls in Lower Running Water Draw watershed. The study focuses on: (a) the effects of erosion control on farm income, (b) off-site sediment damages in the watershed; (c) the costs of administering and enforcing alternative erosion controls, and (d) on-farm economics of soil conservation practices. Erosion controls considered include the traditional voluntary programs combined with economic incentives as well as possible regulatory programs. The focus of the study is on erosion and sedimentation because sediment is a potential transporter of pollutants. Practices to control agricultural non-point source pollution would probably be aimed at reducing soil loss. Conservation and conservation related practices are, at present, considered the best technical practices to abate agricultural non-point source pollution. This is a study of both conservation and environmental economics, two areas that tend to be closely related. For this project, the concern was over potential pollution (an off-site problem), but because of long-run farm income consequences, this concern cannot be separated from conservation problems (an on-farm problem). Accordingly, the report contains substantial information on the short and long-run on-farm benefits and costs of various soil conservation practices for the specific soil mapping units in Lower Running Water Draw watershed. The results of this study are applicable to the majority of the soils in the High Plains Land Resource Area. Only sheet and rill erosion are considered in the study. The first section of the report describes the selected "Best Management Practices" and examines the on-farm economics of soil conservation. The second section postulates various sediment damage control options and models the economic consequences of implementation, both to agricultural producers as a group, and to society.

Reneau, D. R.; Taylor, C. R.; Harris, B. L.; Lacewell, R. D.; Mueller, P. E.

1978-08-01T23:59:59.000Z

436

Hot Diggity Dog CFC Fundraiser | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sites Power Marketing Administration Other Agencies You are here Home Hot Diggity Dog CFC Fundraiser Hot Diggity Dog CFC Fundraiser Hot Diggity Dog CFC Fundraiser December...

437

Solar space- and water-heating system at Stanford University. Final report  

DOE Green Energy (OSTI)

Application of an active hydronic domestic hot water and space heating solar system for the Central Food Services Building is discussed. The closed-loop drain-back system is described as offering dependability of gravity drain-back freeze protection, low maintenance, minimal costs, and simplicity. The system features an 840 square-foot collector and storage capacity of 1550 gallons. The acceptance testing and the predicted system performance data are briefly described. Solar performance calculations were performed using a computer design program (FCHART). Bidding, costs, and economics of the system are reviewed. Problems are discussed and solutions and recommendations given. An operation and maintenance manual is given in Appendix A, and Appendix B presents As-built Drawings. (MCW)

Not Available

1980-05-01T23:59:59.000Z

438

Paper supercapacitors by a solvent-free drawing method Guangyuan Zheng,a  

E-Print Network (OSTI)

Paper supercapacitors by a solvent-free drawing method Guangyuan Zheng,a Liangbing Hu,b Hui Wu designed and fabricated supercapacitors by directly drawing graphite on cellulose paper. The supercapacitors show stable long cycling performance and a high areal capacitance of 2.3 mF cm?2 , which is much

Cui, Yi

439

Acord 1-26 hot, dry well, Roosevelt Hot Springs hot dry rock prospect, Utah  

DOE Green Energy (OSTI)

The Acord 1-26 well is a hot, dry well peripheral to the Roosevelt Hot Springs known geothermal resource area (KGRA) in southwestern Utah. The bottom-hole temperature in this 3854-m-deep well is 230/sup 0/C, and the thermal gradient is 54/sup 0/C/km. The basal 685 m, comprised of biotite monzonite and quartz schist and gneiss, is a likely hot, dry rock (HDR) prospect. The hole was drilled in a structural low within the Milford Valley graben and is separated from the Roosevelt KGRA to the east by the Opal Mound Fault and other basin faults. An interpretation of seismic data approximates the subsurface structure around the well using the lithology in the Acord 1-26 well. The hole was drilled with a minimum of difficulty, and casing was set to 2411 m. From drilling and geophysical logs, it is deduced that the subsurface blocks of crystalline rock in the vicinity of the Acord 1-26 well are tight, dry, shallow, impermeable, and very hot. A hydraulic fracture test of the crystalline rocks below 3170 m is recommended. Various downhole tools and techniques could be tested in promising HDR regimes within the Acord 1-26 well.

Shannon, S.S. Jr.; Pettitt, R.; Rowley, J.; Goff, F.; Mathews, M.; Jacobson, J.J.

1983-08-01T23:59:59.000Z

440

Early Guarded-Hot-Plate Apparatus  

Science Conference Proceedings (OSTI)

... published a recommended plan advocating the ... with the US Department of Energy, completed measurements ... hot plate apparatus described above. ...

2011-07-27T23:59:59.000Z

Note: This page contains sample records for the topic "hot water draw" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Drain Water Heat Recovery | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Drain Water Heat Recovery Drain Water Heat Recovery Drain Water Heat Recovery June 15, 2012 - 6:20pm Addthis Diagram of a drain water heat recovery system. Diagram of a drain water heat recovery system. How does it work? Use heat from water you've already used to preheat more hot water, reducing your water heating costs. Any hot water that goes down the drain carries away energy with it. That's typically 80%-90% of the energy used to heat water in a home. Drain-water (or greywater) heat recovery systems capture this energy from water you've already used (for example, to shower, wash dishes, or wash clothing) to preheat cold water entering the water heater or going to other water fixtures. This reduces the amount of energy needed for water heating. How It Works Drain-water heat recovery technology works well with all types of water

442

Drain Water Heat Recovery | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Drain Water Heat Recovery Drain Water Heat Recovery Drain Water Heat Recovery June 15, 2012 - 6:20pm Addthis Diagram of a drain water heat recovery system. Diagram of a drain water heat recovery system. How does it work? Use heat from water you've already used to preheat more hot water, reducing your water heating costs. Any hot water that goes down the drain carries away energy with it. That's typically 80%-90% of the energy used to heat water in a home. Drain-water (or greywater) heat recovery systems capture this energy from water you've already used (for example, to shower, wash dishes, or wash clothing) to preheat cold water entering the water heater or going to other water fixtures. This reduces the amount of energy needed for water heating. How It Works Drain-water heat recovery technology works well with all types of water

443

Trace-Element Distribution In An Active Hydrothermal System, Roosevelt Hot  

Open Energy Info (EERE)

Trace-Element Distribution In An Active Hydrothermal System, Roosevelt Hot Trace-Element Distribution In An Active Hydrothermal System, Roosevelt Hot Springs Thermal Area, Utah Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Trace-Element Distribution In An Active Hydrothermal System, Roosevelt Hot Springs Thermal Area, Utah Details Activities (3) Areas (1) Regions (0) Abstract: Chemical interaction of thermal fluids with reservoir rock in the Roosevelt Hot Springs thermal area, Utah, has resulted in the development of characteristic trace-element dispersion patterns. Multielement analyses of surface rock samples, soil samples and drill cuttings from deep exploration wells provide a three-dimensional perspective of chemical redistribution within this structurally-controlled hot-water geothermal system. Five distinctive elemental suites of chemical enrichment are

444

Geothermometry At Upper Hot Creek Ranch Area (Benoit & Blackwell, 2006) |  

Open Energy Info (EERE)

Geothermometry At Upper Hot Creek Ranch Area (Benoit & Blackwell, 2006) Geothermometry At Upper Hot Creek Ranch Area (Benoit & Blackwell, 2006) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Geothermometry At Upper Hot Creek Ranch Area (Benoit & Blackwell, 2006) Exploration Activity Details Location Upper Hot Creek Ranch Area Exploration Technique Geothermometry Activity Date Usefulness useful DOE-funding Unknown Notes Ten water samples were collected for chemical analysis and interpretation. Analyses of three samples of the UHCR thermal give predicted subsurface temperatures ranging from 317 to 334 oF from the Na-K-Ca, silica (quartz), and Na-Li geothermometers. The fact that all three thermometers closely agree gives the predictions added credibility. References Dick Benoit, David Blackwell (2006) Exploration Of The Upper Hot

445

Dynamics of precipitation pattern formation at geothermal hot springs  

E-Print Network (OSTI)

We formulate and model the dynamics of spatial patterns arising during the precipitation of calcium carbonate from a supersaturated shallow water flow. The model describes the formation of travertine deposits at geothermal hot springs and rimstone dams of calcite in caves. We find explicit solutions for travertine domes at low flow rates, identify the linear instabilities which generate dam and pond formation on sloped substrates, and present simulations of statistical landscape evolution.

Nigel Goldenfeld; Pak Yuen Chan; John Veysey

2006-01-13T23:59:59.000Z

446

Solar water heaters | Open Energy Information  

Open Energy Info (EERE)

water heaters water heaters (Redirected from - Solar Hot Water) Jump to: navigation, search (The following text is derived from the United States Department of Energy's description of Solar Water Heating technology.)[1] Solar Water Heater One of the most cost-effective ways to include renewable technologies into a building is by incorporating solar hot water. A typical residential solar water-heating system reduces the need for conventional water heating by about two-thirds. It minimizes the expense of electricity or fossil fuel to heat the water and reduces the associated environmental impacts. Solar Water Heating for Buildings Most solar water-heating systems for buildings have two main parts: (1) a solar collector and (2) a storage tank. The most common collector used in solar hot water systems is the

447

Hot and Dense QCD Matter  

NLE Websites -- All DOE Office Websites (Extended Search)

QCD Matter QCD Matter A Community White Paper on the Future of Relativistic Heavy-Ion Physics in the US Unraveling the Mysteries of the Strongly Interacting Quark-Gluon-Plasma Executive Summary This document presents the response of the US relativistic heavy-ion community to the request for comments by the NSAC Subcommittee, chaired by Robert Tribble, that is tasked to recommend optimizations to the US Nuclear Science Program over the next five years. The study of the properties of hot and dense QCD matter is one of the four main areas of nuclear physics research described in the 2007 NSAC Long Range Plan. The US nuclear physics community plays a leading role in this research area and has been instrumental in its most important discovery made over the past decade, namely that hot and dense QCD matter acts as a strongly interacting system with unique and previously unexpected

448

Hot atom chemistry and radiopharmaceuticals  

Science Conference Proceedings (OSTI)

The chemical products made in a cyclotron target are a combined result of the chemical effects of the nuclear transformation that made the radioactive atom and the bulk radiolysis in the target. This review uses some well-known examples to understand how hot atom chemistry explains the primary products from a nuclear reaction and then how radiation chemistry is exploited to set up the optimal product for radiosynthesis. It also addresses the chemical effects of nuclear decay. There are important principles that are common to hot atom chemistry and radiopharmaceutical chemistry. Both emphasize short-lived radionuclides and manipulation of high specific activity nuclides. Furthermore, they both rely on radiochromatographic separation for identification of no-carrieradded products.

Krohn, Kenneth A.; Moerlein, Stephen M.; Link, Jeanne M.; Welch, Michael J. [University of Washington, Department of Radiology, Molecular Imaging Center, 1959 NE Pacific St., Box 356004, Seattle, WA 98195-6004 (United States); Washington University, Department of Radiology, Division of Radiological Sciences, 510 South Kingshighway, St. Louis, MO 63110 (United States); University of Washington, Department of Radiology, Molecular Imaging Center, 1959 NE Pacific St., Box 356004, Seattle, WA 98195-6004 (United States); Washington University, Department of Radiology, Division of Radiological Sciences, 510 South Kingshighway, St. Louis, MO 63110 (United States)

2012-12-19T23:59:59.000Z

449

Compact Liquid Waste Evaporator for Cleanup on Hanfords Hot Cells [FULL PAPER  

SciTech Connect

Removal of radionuclide and hazardous contaminants from hot cells in Hanford's 324 Building will produce an aqueous waste stream requiring volume reduction and packaging. This paper describes a compact and remotely-operated evaporator system that was designed for use in the 324 Building's B-Cell (a shielded hot cell) to volume-reduce the waste waters that are generated from pressure washing of hot cell ceiling, wall, and floor surfaces. The evaporator incorporates an electric-heated reboiler to provide evaporation and drying to allow disposal of waste material. Design features of the evaporator system were strongly influenced by the need for remote handling and remote maintenance. Purified water vapor from the evaporation process will be released directly to the hot cell ventilation air.

HOBART, R.L.

2003-11-14T23:59:59.000Z

450

HotSpot | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HotSpot HotSpot HotSpot Current Central Registry Toolbox Version(s): 2.07.1 Code Owner: Department of Energy, Office of Emergency Operations and Lawrence Livermore National Laboratory (LLNL) Description: The HotSpot Health Physics Code is used for safety-analysis of DOE facilities handling nuclear material. Additionally, HotSpot provides emergency response personnel and emergency planners with a fast, field-portable set of software tools for evaluating incidents involving radioactive material. HotSpot provides a fast and usually conservative means for estimation of the radiation effects associated with atmospheric release of radioactive materials. The HotSpot atmospheric dispersion models are designed for near-surface releases, short-range (less than 10 km) dispersion, and short-term (less than 24 hours) release durations in

451

Thermopolis hydrothermal system with an analysis of Hot Springs State Park  

Science Conference Proceedings (OSTI)

Thermopolis is the site of Hot Springs State Park, where numerous hot springs produce nearly 3000 gallons per minute (gpm) of 130/sup 0/F (54/sup 0/C) water. The University of Wyoming Geothermal Resource Assessment Group has studied a 1700-square-mile area centered roughly on the State Park. Available literature, bottom-hole temperatures from over 400 oil well logs, 62 oil field drill stem tests, the Wyoming State Engineer's water well files, 60 formation water analyses, thermal logs of 19 holes, and field investigations of geology and hydrology form the basis of this report.

Hinckley, B.S.; Heasler, H.P.; King, J.K.

1982-01-01T23:59:59.000Z

452

Los Alamos hot dry rock geothermal energy experiment  

DOE Green Energy (OSTI)

Recent heat flow data indicates that about 95,000 sq. mi. in 13 western U.S. states is underlain, at a depth of 5 km (16,400 ft) by hot dry rock at temperatures above 290/sup 0/C (440/sup 0/F.). Therefore a geothermal energy development program was undertaken to develop methods from extracting thermal energy from hot rock in the earth crust by man-made underground circulation systems; demonstrate the commercial feasibility of such systems; and encourage use of this technology. Experiments performed on the Jemez Plateau in New Mexico are described with information on the drilling of boreholes, hydraulic fracturing of hot rocks, well logging, and environmental monitoring to establish base line data and define the potential effects of the project. The technical achievements of the project include boreholes were drilled to 3k (10,000 ft) with bottomhole temperatures of approximately 200/sup 0/C (390/sup 0/F); hydraulic fracturing produced fractured regions with 150 m (500 ft) radii; at least 90 percent of the water injected was recovered; and data was obtained on geologic conditions, seismic effects, and thermal, fracturing, and chemical properties of the downhole rocks. A geothermal power-production system model was formulated for evaluating the total cost of developing power production using a hot-dry-rock geothermal energy source. (LCL)

Pettitt, R.A.

1976-01-01T23:59:59.000Z

453

Tankless Demand Water Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Demand Water Heater Basics Demand Water Heater Basics Tankless Demand Water Heater Basics August 19, 2013 - 2:57pm Addthis Illustration of an electric demand water heater. At the top of the image, the heating unit is shown. Cold water flows in one end of a pipe, flows through and around several curved pipes over the heating elements, and out the other end as hot water. Beneath the heating unit, a typical sink setup is shown. The sink has two pipes coming out the bottom, one for the hot water line and one for the cold water line. Both pipes lead to the heating unit, which is installed in close proximity to the area of hot water use, and is connected to a power source (110 or 220 volts). Demand (tankless or instantaneous) water heaters have heating devices that are activated by the flow of water, so they provide hot water only as

454

Tankless Demand Water Heater Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tankless Demand Water Heater Basics Tankless Demand Water Heater Basics Tankless Demand Water Heater Basics August 19, 2013 - 2:57pm Addthis Illustration of an electric demand water heater. At the top of the image, the heating unit is shown. Cold water flows in one end of a pipe, flows through and around several curved pipes over the heating elements, and out the other end as hot water. Beneath the heating unit, a typical sink setup is shown. The sink has two pipes coming out the bottom, one for the hot water line and one for the cold water line. Both pipes lead to the heating unit, which is installed in close proximity to the area of hot water use, and is connected to a power source (110 or 220 volts). Demand (tankless or instantaneous) water heaters have heating devices that are activated by the flow of water, so they provide hot water only as

455

Environmental assessment for Kelley Hot Spring geothermal project: Kelley Hot Spring Agricultural Center  

DOE Green Energy (OSTI)

The environmental impacts of an integrated swine production unit are analyzed together with necessary ancillary operations deriving its primary energy from a known geothermal reservoir in accordance with policies established by the National Energy Conservation Act. This environmental assessment covers 6 areas designated as potentially feasible project sites, using as the basic criteria for selection ground, surface and geothermal water supplies. The six areas, comprising +- 150 acres each, are within a 2 mile radius of Kelley Hot Springs, a known geothermal resource of many centuries standing, located 16 miles west of Alturas, the county seat of Modoc County, California. The project consists of the construction and operation of a 1360 sow confined pork production complex expandable to 5440 sows. The farrow to finish system for 1360 sows consists of 2 breeding barns, 2 gestation barns, 1 farrowing and 1 nursery barn, 3 growing and 3 finishing barns, a feed mill, a methane generator for waste disposal and water storage ponds. Supporting this are one geothermal well and 1 or 2 cold water wells, all occupying approximately 12 acres. Environmental reconnaissance involving geology, hydrology, soils, vegetation, fauna, air and water quality, socioeconomic, archaelogical and historical, and land use aspects were carefully carried out, impacts assessed and mitigations evaluated.

Neilson, J.A.

1981-04-01T23:59:59.000Z

456

Electric Tankless Water Heater (TWH) Performance Evaluation and System Compatibility Report  

Science Conference Proceedings (OSTI)

The Instantaneous Water Heater or Tankless Water Heater (TWH) or Demand Water Heater is designed to provide hot water on demand without a storage tank. Tank water heaters require energy to maintain the water temperature in the tank when not in demand. In tank water heaters, due to the specific heat of the water, the thermal time constant of the water heater will not allow it to supply hot water at the same rate as it is used, hence the use of the tank, storing hot water for instant availability. In the e...

2005-12-22T23:59:59.000Z

457

Assessment of hot gas contaminant control  

SciTech Connect

The objective of this work is to gather data and information to assist DOE in responding to the NRC recommendation on hot gas cleanup by performing a comprehensive assessment of hot gas cleanup systems for advanced coal-based Integrated Gasification Combined Cycle (IGCC) and Pressurized Fluidized Bed Combustion (PFBC) including the status of development of the components of the hot gas cleanup systems, and the probable cost and performance impacts. The scope and time frame of information gathering is generally responsive to the boundaries set by the National Research council (NRC), but includes a broad range of interests and programs which cover hot gas cleanup through the year 2010. As the status of hot gas cleanup is continually changing, additional current data and information are being obtained for this effort from this 1996 METC Contractors` Review Meeting as well as from the 1996 Pittsburgh Coal Conference, and the University of Karlsruhe Symposium. The technical approach to completing this work consists of: (1) Determination of the status of hot gas cleanup technologies-- particulate collection systems, hot gas desulfurization systems, and trace contaminant removal systems; (2) Determination of hot gas cleanup systems cost and performance sensitivities. Analysis of conceptual IGCC and PFBC plant designs with hot gas cleanup have been performed. The impact of variations in hot gas cleanup technologies on cost and performance was evaluated using parametric analysis of the baseline plant designs and performance sensitivity.

Rutkowski, M.D.; Klett, M.G.; Zaharchuk, R.

1996-12-31T23:59:59.000Z

458

Kelly Hot Spring Geothermal Project: Kelly Hot Spring Agricultural Center preliminary design. Final technical report  

DOE Green Energy (OSTI)

A Phase 1 Preliminary Design, Construction Planning and Economic Analysis has been conducted for the Kelly Hot Spring Agricultural Center in Modoc County, California. The core activity is a 1360 breeding sow, swine raising complex that utilizes direct heat energy from the Kelly Hot Spring geothermal resource. The swine is to be a totally confined operation for producing premium pork in controlled-environment facilities. The complex contains a feed mill, swine raising buildings and a complete waste management facility that produces methane gas to be delivered to a utility company for the production of electricity. The complex produces 6.7 million pounds of live pork (29,353 animals) shipped to slaughter per year; 105,000 cu. ft. of scrubbed methane per day; and fertilizer. Total effluent is less than 200 gpm of agricultural quality-water with full odor control. The methane production rate made possible with geothermal direct heat is equivalent to at least 400 kw continuous. Sale of the methane on a co-generation basis is being discussed with the utility company. The use of geothermal direct heat energy in the complex displaces nearly 350,000 gallons of fuel oil per year. Generation of the biogas displaces an additional 300,000 gallons of fuel oil per year.

Longyear, A.B. (ed.)

1980-08-01T23:59:59.000Z

459

Hot Dry Rock energy annual report fiscal year 1992  

DOE Green Energy (OSTI)

Hot Dry Rock technology took a giant leap forward this year as the long-awaited long-term flow test (LTFT) of the Phase II HDR reservoir at Fenton Hill got underway. Energy was produced on a twenty-four hour a day basis for a continuous period of nearly four months of steady-state testing. Hot water was brought to the surface at 90-100 gallons per minute (gpm) with temperatures of 180[degrees]C (356[degrees]F) and higher. During that time, the HDR plant achieved an on-line record of 98.8%. Surface temperature measurements and temperature logging deep within the wellbore confirmed that no decline in the average temperature of fluid produced from the reservoir occurred. Tracer experiments indicated that flow paths within the reservoir were undergoing continuous change during the test. Remarkably, it appeared that longer flow paths carried a larger proportion of the flow as the test proceeded, while more direct fluid pathways disappeared or carried a significantly reduced flow. In sum, access to hot rock appeared to improve over the span of the test. Water losses during the test averaged 10-12% and showed a slow long-term decline. These results confirmed what had been previously discovered in static pressurization testing: Water consumption declines significantly during extended operation of an HDR reservoir. In combination with a recent demonstration by the Japanese that water losses can be greatly reduced by the proper placement of multiple production wells, the recent results at Fenton Hill have effectively demonstrated that excessive water consumption should not be an issue for a properly engineered HDR facility at a well chosen site.

Duchane, D.V.; Winchester, W.W.

1993-04-01T23:59:59.000Z

460

Hot Dry Rock energy annual report fiscal year 1992  

DOE Green Energy (OSTI)

Hot Dry Rock technology took a giant leap forward this year as the long-awaited long-term flow test (LTFT) of the Phase 2 HDR reservoir at Fenton Hill got underway. Energy was produced on a twenty-four hour a day basis for a continuous period of nearly four months of steady-state testing. Hot