Powered by Deep Web Technologies
Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Complex Quality Assurance of Historical Hourly Surface Airways Meteorological Data  

Science Conference Proceedings (OSTI)

A new complex quality assurance (QA) procedure is developed for historical hourly surface airways meteorological data, recently digitized in a U.S. government–sponsored effort that extends the digital period of record back as early as the late ...

Daniel Y. Graybeal; Arthur T. DeGaetano; Keith L. Eggleston

2004-08-01T23:59:59.000Z

2

Impact of Wind Energy on Hourly Load Following Requirements: An Hourly and Seasonal Analysis; Preprint  

Science Conference Proceedings (OSTI)

The impacts of wind energy on the power system grid can be decomposed into several time scales that include regulation, load following, and unit commitment. Techniques for evaluating the impacts on these time scales are still evolving, and as wind energy becomes a larger part of the electricity supply, valuable experience will be gained that will help refine these methods. Studies that estimated the impact of wind in the load following time scale found differing results and costs, ranging from near zero to approximately $2.50/megawatt-hour (MWh). Part of the reason for these differences is the different interpretation of the impacts that would be allocated to this ancillary service. Because of the low correlation between changes in load and wind, long-term analyses of the load following impact of wind may find low impacts. During the daily load cycle, there is a tremendous variability in load following requirements in systems without wind. When significant levels of wind generation are added to the resource mix, relatively small changes in wind output can complicate the task of balancing the system during periods of large load swings. This paper analyzes the load following impacts of wind by segregating these critical time periods of the day and separating the analysis by season. The analysis compares wind generation at geographically dispersed sites to wind generation based primarily at a single site, and for a large penetration of wind (more than 20% wind capacity to peak load).

Krich, A.; Milligan, M.

2005-05-01T23:59:59.000Z

3

Improved Quality Assurance for Historical Hourly Temperature and Humidity: Development and Application to Environmental Analysis  

Science Conference Proceedings (OSTI)

Historical hourly surface synoptic (airways) meteorological reports from around the United States have been digitized as part of the NOAA Climate Database Modernization Program. An important component is improvement of quality assurance ...

Daniel Y. Graybeal; Arthur T. DeGaetano; Keith L. Eggleston

2004-11-01T23:59:59.000Z

4

Commercial and Residential Hourly Load Data Now Available on OpenEI! |  

Open Energy Info (EERE)

Commercial and Residential Hourly Load Data Now Available on OpenEI! Commercial and Residential Hourly Load Data Now Available on OpenEI! Home > Groups > Utility Rate Sfomail's picture Submitted by Sfomail(48) Member 17 May, 2013 - 12:03 building load building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL I am pleased to announce that simulated hourly residential and commercial building load datasets are now available on OpenEI. These datasets are available for all TMY3 locations in the United States. They contain hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). In addition to various

6

Mirant: Case 67a: Units 3 & 4 & 5 at Max Load for 12 hours and at Min Load  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Mirant: Case 67a: Units 3 & 4 & 5 at Max Load for 12 hours and at Mirant: Case 67a: Units 3 & 4 & 5 at Max Load for 12 hours and at Min Load for 12 hours Mirant: Case 67a: Units 3 & 4 & 5 at Max Load for 12 hours and at Min Load for 12 hours Docket No. EO-05-01. Mirant: Case 67a: Units 3 & 4 & 5 at Max Load for 12 hours and at Min Load for 12 hours. Arial photograph showing plant and location of predicted SO2 violations, predicted in 2000. Mirant: Case 67a: Units 3 & 4 & 5 at Max Load for 12 hours and at Min Load for 12 hours More Documents & Publications Mirant Potomac, Alexandria, Virginia: Maximum Impacts Predicted by AERMOD-PRIME, Units 3, 1, 2 SO2 Case Mirant Potomac, Alexandria, Virginia: Maximum Impacts Predicted by AERMOD-PRIME, Units 4, 1, 2 SO2 Case Mirant Potomac, Alexandria, Virginia: Maximum Impacts Predicted by

7

Commercial and Residential Hourly Load Profiles for all TMY3 Locations in  

Open Energy Info (EERE)

and Residential Hourly Load Profiles for all TMY3 Locations in and Residential Hourly Load Profiles for all TMY3 Locations in the United States Dataset Summary Description This dataset contains hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). This dataset also includes the Residential Energy Consumption Survey (RECS) for statistical references of building types by location. Hourly load profiles are available for over all TMY3 locations in the United States here. Browse files in this dataset, accessible as individual files and as commercial and residential downloadable ZIP files. This dataset is approximately 4.8GiB compressed or 19GiB uncompressed. July 2nd, 2013 update: Residential High and Low load files have been updated from 366 days in a year for leap years to the more general 365 days in a normal year.

8

Effects of electric utility residential conservation programs on hourly load profiles  

SciTech Connect

This paper discusses the potential of using hourly energy simulation models to determine load shape changes resulting from energy conservation activities. It is determined that shifts in the time and the day of the monthly peak demand may occur as the level of conservation increases. The shifting of the peak was from weather-sensitive periods to less-weather-sensitive periods. Seasonal load profile changes resulting from energy conservation were demonstrated. A statistically significant quadratic relationship was identified between the annual percent reduction and annual percent energy conserved for the different distribution systems examined. The relationships are examined between different levels of residential energy conservation from weatherization and heat pumps on the hourly load profiles of different power distribution systems within the TVA power service area.

Harper, J.P.; Sieber, R.E.

1983-01-01T23:59:59.000Z

9

Regional load-curve models: QUERI's model long-run forecasts and sensitivity analysis. Volume 4. Final report. [Hourly demand in 32 US regions  

SciTech Connect

This report presents detailed forecasts of the hourly demand for electricity in 32 regions of the US through the year 2000. The forecasts are generated by a load curve model estimated by QUERI and described in Volume II of this report. Two primary sets of input assumptions for this model are utilized: one based on DRI's macro, regional and sectoral models is called the Baseline Scenario while the other, which is a projection of historical trends, is the Extrapolation Scenario. Under both assumptions, the growth rates of electricity are forecast to slow from historical levels. Load factors are generally projected to continue to decline; most regions are forecast to remain Summer peaking but this is rather sensitive to the choice of scenario. By considering other scenarios which are small perturbations of the Baseline assumptions, elasticities of average, peak and hourly loads are calculated. Different weather assumptions are also examined for the sensitivity of the load shapes to changes in the weather.

Engle, R.F.; Granger, C.W.J.; Ramanathan, R.

1981-09-01T23:59:59.000Z

10

After-hours Power Status of Office Equipment and Inventory of Miscellaneous Plug-load Equipment  

Science Conference Proceedings (OSTI)

This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of ''miscellaneous'' plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers. This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from twelve commercial buildings in California, Georgia, and Pennsylvania: two health care buildings, two large offices (> 500 employees each), three medium offices (50-500 employees), four education buildings, and one ''small office'' that is actually an aggregate of five small businesses. Two buildings are in the San Francisco Bay area of California, five are in Pittsburgh, Pennsylvania, and five are in Atlanta, Georgia.

Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Margaret J.; Busch, John F.

2004-01-22T23:59:59.000Z

11

Short Term Hourly Load Forecasting Using Abductive Networks R. E. Abdel-Aal  

E-Print Network (OSTI)

--Congestion forecasting, price forecasting, wholesale power market, locational marginal price, load partitioning, convex for system planning.1 Many studies have focused on electricity price forecasting based on statistical tools distributed loads and DC-OPF system variable solutions was identified and applied to forecast congestion

Abdel-Aal, Radwan E.

12

Climatic-related Evaluations of the Summer Peak-Hours' Electric Load in Israel  

Science Conference Proceedings (OSTI)

The interrelationship between the Summer peak electric load in Israel and pertinent meteorological parameters, including the commonly used outdoor biometeorological comfort index, is evaluated conceptually and statistically. Linear regression ...

M. Segal; H. Shafir; M. Mandel; P. Alpert; Y. Balmor

1992-12-01T23:59:59.000Z

13

A Historical Perspective and Business Model for Load Response Aggregation Based on Priority Service  

E-Print Network (OSTI)

A Historical Perspective and Business Model for Load Response Aggregation Based on Priority Service] limits consumption during peak demand periods and is set by the customer according to a rate agreements of a colored light indicator which tariff is active. In its June 17, 1985 issue Electric Utility Week published

Oren, Shmuel S.

14

Historical Data  

NLE Websites -- All DOE Office Websites (Extended Search)

Data Historical Data Edison Phase I Hours Used Hours used per day on Hopper. Read More Franklin Hours Used Hours used per day on Franklin. Read More Last edited: 2013-08-28...

15

After-hours power status of office equipment and energy use of miscellaneous plug-load equipment  

Science Conference Proceedings (OSTI)

This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of miscellaneous plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers. For most types of miscellaneous equipment, we also estimated typical unit energy consumption in order to estimate total energy consumption of the miscellaneous devices within our sample. This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from sixteen commercial buildings in California, Georgia, and Pennsylvania: four education buildings, two medical buildings, two large offices (> 500 employees each), three medium offices (50-500 employees each), and five small business offices (< 50 employees each). Two buildings are in the San Francisco Bay are a of California, nine (including the five small businesses) are in Pittsburgh, Pennsylvania, and five are in Atlanta, Georgia.

Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Marageret J.; Busch, John F.

2004-05-27T23:59:59.000Z

16

Observed Temperature Effects on Hourly Residential Electric Load Reduction in Response to an Experimental Critical Peak Pricing Tariff  

E-Print Network (OSTI)

changes to retail electricity rates on an hourly or dailyweekdays 2004 [6] Most electricity rates in use today arerates with control technologies use 30- 40% less electricity

Herter, Karen B.; McAuliffe, Patrick K.; Rosenfeld, Arthur H.

2005-01-01T23:59:59.000Z

17

Using Utility Load Data to Estimate Demand for Space Cooling and Potential for Shiftable Loads  

SciTech Connect

This paper describes a simple method to estimate hourly cooling demand from historical utility load data. It compares total hourly demand to demand on cool days and compares these estimates of total cooling demand to previous regional and national estimates. Load profiles generated from this method may be used to estimate the potential for aggregated demand response or load shifting via cold storage.

Denholm, P.; Ong, S.; Booten, C.

2012-05-01T23:59:59.000Z

18

Observed Temperature Effects on Hourly Residential Electric LoadReduction in Response to an Experimental Critical Peak PricingTariff  

SciTech Connect

The goal of this investigation was to characterize themanual and automated response of residential customers to high-price"critical" events dispatched under critical peak pricing tariffs testedin the 2003-2004 California Statewide Pricing Pilot. The 15-monthexperimental tariff gave customers a discounted two-price time-of-userate on 430 days in exchange for 27 critical days, during which the peakperiod price (2 p.m. to 7 p.m.) was increased to about three times thenormal time-of-use peak price. We calculated response by five-degreetemperature bins as the difference between peak usage on normal andcritical weekdays. Results indicatedthat manual response to criticalperiods reached -0.23 kW per home (-13 percent) in hot weather(95-104.9oF), -0.03 kW per home (-4 percent) in mild weather (60-94.9oF),and -0.07 kW per home (-9 percent) during cold weather (50-59.9oF).Separately, we analyzed response enhanced by programmable communicatingthermostats in high-use homes with air-conditioning. Between 90oF and94.9oF, the response of this group reached -0.56 kW per home (-25percent) for five-hour critical periods and -0.89 kW/home (-41 percent)for two-hour critical periods.

Herter, Karen B.; McAuliffe, Patrick K.; Rosenfeld, Arthur H.

2005-11-14T23:59:59.000Z

19

A Historical Perspective and Business Model for Load Response Aggregation Based on Priority Service  

Science Conference Proceedings (OSTI)

We review early technologies and experiments in the 1980's for implementing demand response. We argue that while new smart grid technologies are cheaper and provide more functionality the barrier to demand response implementation at the retail level ... Keywords: Priority Service, Demand Response, Load Response Aggragation, Energy Economics

Shmuel S. Oren

2013-01-01T23:59:59.000Z

20

hourly | OpenEI  

Open Energy Info (EERE)

hourly hourly Dataset Summary Description This dataset contains hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). This dataset also includes the Residential Energy Consumption Survey (RECS) for statistical references of building types by location. Source Commercial and Residential Reference Building Models Date Released April 18th, 2013 (7 months ago) Date Updated July 02nd, 2013 (5 months ago) Keywords building building demand building load Commercial data demand Energy Consumption energy data hourly kWh load profiles Residential Data Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

A Climatological Measure of Extreme Snowdrift Loading on Building Roofs  

Science Conference Proceedings (OSTI)

A physical model of snow transport and deposition is used in combination with historical climatological data to derive a climatological measure of extreme snowdrift loads on building roofs. The snowdrift metric used relies on hourly wind speed, ...

Arthur T. DeGaetano; Michael J. O'Rourke

2004-01-01T23:59:59.000Z

22

Teach Yourself in 24 Hours  

E-Print Network (OSTI)

"ations .................................................. 302 Reclaiming Memory with the kill Command .................................. 303 Getting System Load in a retrieval system, or transmitted by any means, electronic, mechanical, photo- copying, recording 1 Hour 1 Preparing to Install Linux 3 2 Installing Linux 11 3 Configuring the X Window System 31

Eckmiller, Rolf

23

Does EIA publish data on peak or hourly electricity ...  

U.S. Energy Information Administration (EIA)

Financial market analysis and financial ... load (or demand) data in our Electric Power Annual ... hourly load/demand profiles for some Independent ...

24

Load-shape modeling in southeastern utility systems  

SciTech Connect

Load models are tools which have a wide range of application in the electric-utility industry. Some uses include monitoring load-management policies and helping with on-line commitment problems. The output from a load model can be placed in a suitable software environment where daily load curves are computed and displayed. Also, load models can be extended to perform forecasting functions. A weather sensitive load model that takes into account both weekdays and weekends on an hourly basis has been developed and applied to load shape modeling and short term forecasting on three southeastern electric utilities. A software package associated with the load modeling theory was developed and tested. This load-modeling program computes the daily load curve in terms of identifiable components. The program uses historical hourly load data to compute coefficients related to load components including base, growth, seasonal and weather. These coefficients can be used in a mathematical model to compute an estimate of the daily load curve with load values for each hour of the day. The load-modeling procedure described employs a linear least squares method for computing coefficients in the mathematical model.

Lebby, G.L.

1985-01-01T23:59:59.000Z

25

OpenEI - hourly  

Open Energy Info (EERE)

are given by a location defined by the Typical Meteorological Year (TMY) for which the weather data was collected. Commercial load data is sorted by the (TMY) site as a...

26

Historical Context  

NLE Websites -- All DOE Office Websites (Extended Search)

Context Historical Context for the Conversion EISs Important events and decisions that led to development of the depleted UF6 Conversion EISs. 1992: Concerns Raised by Ohio...

27

NERSC Edison Hours Used Report  

NLE Websites -- All DOE Office Websites (Extended Search)

Edison Hours Used Edison Hours Used Edison Usage Chart Edison Usage Chart Date Hours Used (in millions) Percent of Maximum Possible (24 hoursday) 10142013 1.852 61.8 10132013...

28

hourly emission factors | OpenEI  

Open Energy Info (EERE)

60 60 Varnish cache server Browse Upload data GDR 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142278660 Varnish cache server hourly emission factors Dataset Summary Description Emissions from energy use in buildings are usually estimated on an annual basis using annual average multipliers. Using annual numbers provides a reasonable estimation of emissions, but it provides no indication of the temporal nature of the emissions. Therefore, there is no way of understanding the impact on emissions from load shifting and peak shaving technologies such as thermal energy storage, on-site renewable energy, and demand control. Source NREL Date Released April 11th, 2011 (3 years ago) Date Updated April 11th, 2011 (3 years ago)

29

A Comparison of Forecast Error Generators for Modeling Wind and Load Uncertainty  

SciTech Connect

This paper presents four algorithms to generate random forecast error time series, including a truncated-normal distribution model, a state-space based Markov model, a seasonal autoregressive moving average (ARMA) model, and a stochastic-optimization based model. The error time series are used to create real-time (RT), hour-ahead (HA), and day-ahead (DA) wind and load forecast time series that statistically match historically observed forecasting data sets, used for variable generation integration studies. A comparison is made using historical DA load forecast and actual load values to generate new sets of DA forecasts with similar stoical forecast error characteristics. This paper discusses and compares the capabilities of each algorithm to preserve the characteristics of the historical forecast data sets.

Lu, Ning; Diao, Ruisheng; Hafen, Ryan P.; Samaan, Nader A.; Makarov, Yuri V.

2013-12-18T23:59:59.000Z

30

Historical Tracking  

Science Conference Proceedings (OSTI)

...Historical tracking is a process of measuring, recording, and analyzing one or more specific characteristics of a process. This record then becomes the basis on which the current state of the process can be assessed and the future state of the process predicted....

31

OpenEI - hourly data  

Open Energy Info (EERE)

http:en.openei.orgdatasetstaxonomyterm4980 en Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and diffuse) data for selected stations in Sri Lanka from...

32

Transitioning to 12-hour shifts  

Science Conference Proceedings (OSTI)

In 1989, Yankee Rowe nuclear power station successfully implemented a 12-hour shift schedule for all shiftworkers (control room personnel, auxiliary operators, and radiation protection shift technicians) with many positive effects on morale, motivation, and performance. The transition from an 8-hour to a 12-hour shift schedule was initiated, organized, and promoted by the shiftworkers themselves after they had identified numerous inadequacies in the 8-hour shift schedule. Preliminary and final implementation required several steps: (a) a survey of needs, (b) research of potential schedules, (c) cost/benefit analysis, (d) resolution of any union contract conflicts, (e) management approval, and (f) trial shift schedule periods.

Suter, P.S.; Cervassi, S.M.

1993-03-01T23:59:59.000Z

33

NERSC Franklin Hours Used Report  

NLE Websites -- All DOE Office Websites (Extended Search)

Franklin Hours Used Franklin Hours Used Franklin Hours Used 2011 Franklin Usage in Hours 2011 Franklin Usage in Hours 2010 2010 Franklin Usage in Hours 2009 2009 Franklin Usage in Hours 2007-2008 2008 Franklin Usage in Hours 2008 Franklin Usage in Hours Date Hours Used (in thousands) Percentage of Maximum Possible (24 hours/day) 04/28/2012 0.00 0.00 04/27/2012 272.62 29.40 04/26/2012 692.81 74.71 04/25/2012 841.60 90.75 04/24/2012 53.86 5.81 04/23/2012 432.01 46.59 04/22/2012 823.23 88.77 04/21/2012 473.95 51.11 04/20/2012 173.75 18.74 04/19/2012 449.22 48.44 04/18/2012 816.23 88.02 04/17/2012 754.35 81.34 04/16/2012 648.89 69.97 04/15/2012 812.25 87.59 04/14/2012 843.46 90.95 04/13/2012 737.46 79.52 04/12/2012 711.97 76.77 04/11/2012 734.65 79.22 04/10/2012 815.65 87.95 04/09/2012 897.25 96.75

34

Historical. Information.  

Office of Legacy Management (LM)

Historical. Information. Historical. Information. ~ H.. 1 . General Project Rulison Manager' s Report, April. 1973 DISCLAIMER Portions of this document may be illegible in electronic image products. Images are produced from the best available original document. PROJECT RULISON MANAGER'S R E P O R T APRIL 197.3 UNITED STATES ATOMIC ENERGY COMMISSION NEVADA OPERATIONS OFFICE Las Vegas, Nevada PREFACE , The R u l i s o n ' p r o j e c t , d e t o n a t e d September 1 0 , 1969, 'was t h e second n u c l e a r . d e t o n a t i o n designed t o d e t e r m i n e t h e economic and t e c h n i c a l f e a s i b i l i t y . of u s i n g n u c l e a r e x p l o s i v e s t o s t i m u l a t e an underground, low-productivity n a t u r a l gas r e s e r v o i r . The p r o j e c t was p a r t of t h e Atomic Energy Commission's (AEC) Plowshare program f o r d e v e l o p i n g p e a c e f u l a p p l i c a t i o n of n u c l e a r e x p l

35

Transportation Electrification Load Development For A Renewable Future Analysis: Preprint  

DOE Green Energy (OSTI)

The transition to electricity as a transportation fuel will create a new load for electricity generation. A set of regional hourly load profiles for electrified vehicles was developed for the 2010 to 2050 timeframe. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determine the number of plug-in electric vehicles (PEVs) in each analysis region. Market saturation scenarios of 30% and 50% of sales of PEVs consuming on average approx. 6 kWh per day were considered. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging toward utility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across four daily time slices under optimal control from the utility?s perspective. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetration scenarios.

Markel, T.; Mai, T.; Kintner-Meyer, M.

2010-12-01T23:59:59.000Z

36

load profile | OpenEI Community  

Open Energy Info (EERE)

load profile Home Sfomail's picture Submitted by Sfomail(48) Member 17 May, 2013 - 13:03 Commercial and Residential Hourly Load Data Now Available on OpenEI building load building...

37

Analysis of industrial load management  

SciTech Connect

Industrial Load Management, ILM, has increased the possibilities of changing load profiles and raising load factors. This paper reports on load profile measurements and feasible load management applications that could be implemented in industry e.g. bivalent systems for heating of premises and processes, load priority systems, energy storage and rescheduling processes or parts of processes due to differential electricity rates. Industrial load variations on hourly, daily and seasonal basis are treated as well as the impact by load management on load curves e g peak clipping, valley filling and increased off-peak electricity usage.

Bjork, C.O.; Karlsson, B.G.

1986-04-01T23:59:59.000Z

38

NERSC Carver Hours Used Report  

NLE Websites -- All DOE Office Websites (Extended Search)

Carver Hours Carver Hours Used Carver Hours Used Hopper Usage Chart Hopper Usage Chart Date Hours Used (in millions) Percent of Maximum Possible (24 hours/day) 01/05/2014 170.00 89.35 01/04/2014 174.38 91.65 01/03/2014 174.15 91.53 01/02/2014 179.72 94.45 01/01/2014 173.76 91.32 12/31/2013 172.25 90.53 12/30/2013 169.62 89.14 12/29/2013 164.72 86.57 12/28/2013 177.92 93.51 12/27/2013 171.61 90.19 12/26/2013 172.74 90.79 12/25/2013 172.13 90.46 12/24/2013 173.48 91.18 12/23/2013 174.92 91.93 12/22/2013 175.26 92.11 12/21/2013 173.58 91.23 12/20/2013 174.50 91.71 12/19/2013 170.02 89.36 12/18/2013 178.25 93.68 12/17/2013 176.17 92.59 12/16/2013 162.03 85.16 12/15/2013 157.09 82.56 12/14/2013 173.40 91.13 12/13/2013 185.02 97.24 12/12/2013 150.91 79.31 12/11/2013 31.67 16.64 12/10/2013 92.44 48.58

39

A Comparison of Forecast Error Generators for Modeling Wind and Load Uncertainty  

Science Conference Proceedings (OSTI)

This paper presents four algorithms to generate random forecast error time series. The performance of four algorithms is compared. The error time series are used to create real-time (RT), hour-ahead (HA), and day-ahead (DA) wind and load forecast time series that statistically match historically observed forecasting data sets used in power grid operation to study the net load balancing need in variable generation integration studies. The four algorithms are truncated-normal distribution models, state-space based Markov models, seasonal autoregressive moving average (ARMA) models, and a stochastic-optimization based approach. The comparison is made using historical DA load forecast and actual load values to generate new sets of DA forecasts with similar stoical forecast error characteristics (i.e., mean, standard deviation, autocorrelation, and cross-correlation). The results show that all methods generate satisfactory results. One method may preserve one or two required statistical characteristics better the other methods, but may not preserve other statistical characteristics as well compared with the other methods. Because the wind and load forecast error generators are used in wind integration studies to produce wind and load forecasts time series for stochastic planning processes, it is sometimes critical to use multiple methods to generate the error time series to obtain a statistically robust result. Therefore, this paper discusses and compares the capabilities of each algorithm to preserve the characteristics of the historical forecast data sets.

Lu, Ning; Diao, Ruisheng; Hafen, Ryan P.; Samaan, Nader A.; Makarov, Yuri V.

2013-07-25T23:59:59.000Z

40

hourly data | OpenEI  

Open Energy Info (EERE)

data data Dataset Summary Description (Abstract): Each data file is a set of hourly values of solar radiation and meteorological elements for a 1-year period. Solar radiation is modeled using the NREL METSTAT model, with surface observed cloud cover being the principal model input. Each container file contains up to 30 yearly files for one station, plus the Typical Meteorological Year (TMY) file for the selected station, plus documentation files and a TMY data reader file for use with Microsoft Excel. Source U.S. National Renewable Energy Laboratory (NREL) Date Released May 03rd, 2005 (9 years ago) Date Updated November 01st, 2007 (7 years ago) Keywords DNI GHI hourly data NREL solar Sri Lanka SWERA TILT TMY UNEP Data application/zip icon Download TMY data (zip, 67.5 MiB)

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Historical Natural Gas Annual  

Annual Energy Outlook 2012 (EIA)

8 The Historical Natural Gas Annual contains historical information on supply and disposition of natural gas at the national, regional, and State level as well as prices at...

42

Historical Natural Gas Annual  

Gasoline and Diesel Fuel Update (EIA)

7 The Historical Natural Gas Annual contains historical information on supply and disposition of natural gas at the national, regional, and State level as well as prices at...

43

Historical Natural Gas Annual  

Annual Energy Outlook 2012 (EIA)

6 The Historical Natural Gas Annual contains historical information on supply and disposition of natural gas at the national, regional, and State level as well as prices at...

44

load | OpenEI  

Open Energy Info (EERE)

load load Dataset Summary Description This dataset contains hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). This dataset also includes the Residential Energy Consumption Survey (RECS) for statistical references of building types by location. Source Commercial and Residential Reference Building Models Date Released April 18th, 2013 (9 months ago) Date Updated July 02nd, 2013 (7 months ago) Keywords building building demand building load Commercial data demand Energy Consumption energy data hourly kWh load profiles Residential Data Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually

45

Predicting hourly building energy usage  

SciTech Connect

This article presents the results of an evaluation to identify the most accurate method for making hourly energy use predictions. The prediction of energy usage by HVAC systems is important for the purposes of HVAC diagnostics, system control, parameter and system identification, optimization and energy management. Many new techniques are now being applied to the analysis problems involved with predicting the future behavior of HVAC systems and deducing properties of these systems. Similar problems arise in most observational disciplines, including physics, biology and economics.

Kreider, J.F. (Univ. of Colorado, Boulder, CO (United States). Dept. of Civil, Environmental and Architectural Engineering); Haberl, J.S. (Texas A and M Univ., College Station, TX (United States). Mechanical Engineering Dept.)

1994-06-01T23:59:59.000Z

46

Estimation of Daily Degree-hours  

Science Conference Proceedings (OSTI)

Degree-hours have many applications in fields such as agriculture, architecture, and power generation. Since daily mean temperatures are more readily available than hourly temperatures, the difference between mean daily degree-hours computed from ...

Nathaniel B. Guttman; Richard L. Lehman

1992-07-01T23:59:59.000Z

47

Estimating Demand Response Load Impacts: Evaluation of BaselineLoad Models for Non-Residential Buildings in California  

SciTech Connect

Both Federal and California state policymakers areincreasingly interested in developing more standardized and consistentapproaches to estimate and verify the load impacts of demand responseprograms and dynamic pricing tariffs. This study describes a statisticalanalysis of the performance of different models used to calculate thebaseline electric load for commercial buildings participating in ademand-response (DR) program, with emphasis onthe importance of weathereffects. During a DR event, a variety of adjustments may be made tobuilding operation, with the goal of reducing the building peak electricload. In order to determine the actual peak load reduction, an estimateof what the load would have been on the day of the event without any DRactions is needed. This baseline load profile (BLP) is key to accuratelyassessing the load impacts from event-based DR programs and may alsoimpact payment settlements for certain types of DR programs. We testedseven baseline models on a sample of 33 buildings located in California.These models can be loosely categorized into two groups: (1) averagingmethods, which use some linear combination of hourly load values fromprevious days to predict the load on the event, and (2) explicit weathermodels, which use a formula based on local hourly temperature to predictthe load. The models were tested both with and without morningadjustments, which use data from the day of the event to adjust theestimated BLP up or down.Key findings from this study are: - The accuracyof the BLP model currently used by California utilities to estimate loadreductions in several DR programs (i.e., hourly usage in highest 3 out of10 previous days) could be improved substantially if a morning adjustmentfactor were applied for weather-sensitive commercial and institutionalbuildings. - Applying a morning adjustment factor significantly reducesthe bias and improves the accuracy of all BLP models examined in oursample of buildings. - For buildings with low load variability, all BLPmodels perform reasonably well in accuracy. - For customer accounts withhighly variable loads, we found that no BLP model produced satisfactoryresults, although averaging methods perform best in accuracy (but notbias). These types of customers are difficult to characterize withstandard BLP models that rely on historic loads and weather data.Implications of these results for DR program administrators andpolicymakersare: - Most DR programs apply similar DR BLP methods tocommercial and industrial sector customers. The results of our study whencombined with other recent studies (Quantum 2004 and 2006, Buege et al.,2006) suggests that DR program administrators should have flexibility andmultiple options for suggesting the most appropriate BLP method forspecific types of customers.

Coughlin, Katie; Piette, Mary Ann; Goldman, Charles; Kiliccote,Sila

2008-01-01T23:59:59.000Z

48

Definition: Kilowatt-hour | Open Energy Information  

Open Energy Info (EERE)

Kilowatt-hour Kilowatt-hour Jump to: navigation, search Dictionary.png Kilowatt-hour A unit of measure for energy, typically applied to electricity usage; equal to the amount of energy used at a rate of 1,000 watts over the course of one hour. One kWh is equivalent to 3,412 Btu, or 3,600 kJ.[1][2] View on Wikipedia Wikipedia Definition The kilowatt hour, or kilowatt-hour, (symbol kW·h, kW h or kWh) is a unit of energy equal to 1000 watt hours or 3.6 megajoules. For constant power, energy in watt hours is the product of power in watts and time in hours. The kilowatt hour is most commonly known as a billing unit for energy delivered to consumers by electric utilities. Also Known As kWh Related Terms British thermal unit, Electricity, Energy, Kilowatt, energy, electricity generation

49

Residential equipment part load curves for use in DOE-2  

SciTech Connect

DOE-2 (DOE2 90) includes several correlation curves that predict the energy use of systems underpart load conditions. DOE-2 simulates systems on an hour-by-hour basis, so the correlations are intended to predict part load energy use (and efficiency) as a function of the part load ratio (PLR) for each hour, where PLR = Hourly Load/Available Capacity. Generally residential and small commercial HVAC equipment meets the load at off-design conditions by cycling on and off. Therefore, the part load correlations must predict the degradation due to this on and off operation over an hourly interval.

Henderson, Hugh; Huang, Y.J.; Parker, D.

1999-02-01T23:59:59.000Z

50

Transportation Electrification Load Development For a Renewable Future Analysis  

SciTech Connect

Electrification of the transportation sector offers the opportunity to significantly reduce petroleum consumption. The transportation sector accounts for 70% of US petroleum consumption. The transition to electricity as a transportation fuel will create a new load for electricity generation. In support of a recent US Department of Energy funded activity that analyzed a future generation scenario with high renewable energy technology contributions, a set of regional hourly load profiles for electrified vehicles were developed for the 2010 to 2050 timeframe. These load profiles with their underlying assumptions will be presented in this paper. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determine the number of plug-in electric vehicles (PEVs) in each analysis region. Two market saturation scenarios of 30% of sales and 50% of sales of PEVs consuming on average {approx}6 kWh per day were considered. Results were generated for 3109 counties and were consolidated to 134 Power Control Areas (PCA) for the use NREL's's regional generation planning analysis tool ReEDS. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging toward utility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across 4 daily time slices under optimal control from the utility perspective. No other literature has addressed the potential flexibility in energy delivery to electric vehicles in connection with a regional power generation study. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetration scenarios. EVS25 Copyright.

Markel, Tony; Mai, Trieu; Kintner-Meyer, Michael CW

2010-09-30T23:59:59.000Z

51

ANS Nuclear Historic Landmark  

Science Conference Proceedings (OSTI)

... NCNR declared a Nuclear Historic Landmark by the American Nuclear Society. The NIST Center for Neutron Research ...

52

The Autocorrelation of Hourly Wind Speed Observations  

Science Conference Proceedings (OSTI)

The autocorrelation of hourly wind speed observations is estimated for seven stations on the west coast of Canada at selected lags ranging from one hour to two months. The estimated autocorrelation function is fitted by a model that includes a ...

Arthur C. Brett; Stanton E. Tuller

1991-06-01T23:59:59.000Z

53

Hourly Energy Emission Factors for Electricity Generation in the United  

Open Energy Info (EERE)

Hourly Energy Emission Factors for Electricity Generation in the United Hourly Energy Emission Factors for Electricity Generation in the United States Dataset Summary Description Emissions from energy use in buildings are usually estimated on an annual basis using annual average multipliers. Using annual numbers provides a reasonable estimation of emissions, but it provides no indication of the temporal nature of the emissions. Therefore, there is no way of understanding the impact on emissions from load shifting and peak shaving technologies such as thermal energy storage, on-site renewable energy, and demand control. This project utilized GridViewTM, an electric grid dispatch software package, to estimate hourly emission factors for all of the eGRID subregions in the continental United States. These factors took into account electricity imports and exports

54

Virtualizing office hours in CS 50  

Science Conference Proceedings (OSTI)

In Fall 2007, we introduced "virtual office hours" into Harvard College's introductory computer science course, CS 50, so that students could meet with teaching fellows (TFs) online to discuss problem sets at any hour from anywhere. Our goals were to ... Keywords: CSCW, collaboration, distance education, virtual office hours

David J. Malan

2009-07-01T23:59:59.000Z

55

Historical Natural Gas Annual  

Gasoline and Diesel Fuel Update (EIA)

6 6 The Historical Natural Gas Annual contains historical information on supply and disposition of natural gas at the national, regional, and State level as well as prices at selected points in the flow of gas from the wellhead to the burner-tip. Data include production, transmission within the United States, imports and exports of natural gas, underground storage activities, and deliveries to consumers. The publication presents historical data at the national level for 1930-1996 and detailed annual historical information by State for 1967-1996. The Historical Natural Gas Annual tables are available as self-extracting executable files in ASCII TXT or CDF file formats. Tables 1-3 present annual historical data at the national level for 1930-1996. The remaining tables contain detailed annual historical information, by State, for 1967-1996. Please read the file entitled READMEV2 for a description and documentation of information included in this file.

56

Historical Natural Gas Annual  

Gasoline and Diesel Fuel Update (EIA)

7 7 The Historical Natural Gas Annual contains historical information on supply and disposition of natural gas at the national, regional, and State level as well as prices at selected points in the flow of gas from the wellhead to the burner-tip. Data include production, transmission within the United States, imports and exports of natural gas, underground storage activities, and deliveries to consumers. The publication presents historical data at the national level for 1930-1997 and detailed annual historical information by State for 1967-1997. The Historical Natural Gas Annual tables are available as self-extracting executable files in ASCII TXT or CDF file formats. Tables 1-3 present annual historical data at the national level for 1930-1997. The remaining tables contain detailed annual historical information, by State, for 1967-1997. Please read the file entitled READMEV2 for a description and documentation of information included in this file.

57

Historical Natural Gas Annual  

Gasoline and Diesel Fuel Update (EIA)

8 8 The Historical Natural Gas Annual contains historical information on supply and disposition of natural gas at the national, regional, and State level as well as prices at selected points in the flow of gas from the wellhead to the burner-tip. Data include production, transmission within the United States, imports and exports of natural gas, underground storage activities, and deliveries to consumers. The publication presents historical data at the national level for 1930-1998 and detailed annual historical information by State for 1967-1998. The Historical Natural Gas Annual tables are available as self-extracting executable files in ASCII TXT or CDF file formats. Tables 1-3 present annual historical data at the national level for 1930-1998. The remaining tables contain detailed annual historical information, by State, for 1967-1998. Please read the file entitled READMEV2 for a description and documentation of information included in this file.

58

Texas Historical Commission | Open Energy Information  

Open Energy Info (EERE)

Historical Commission Historical Commission Jump to: navigation, search Logo: Texas Historical Commission Name Texas Historical Commission Address 1511 Colorado St. Place Austin, Texas Zip 78701 Year founded 1953 Phone number 512.463.6100 Website http://www.thc.state.tx.us/ Coordinates 30.2779484°, -97.7403973° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":30.2779484,"lon":-97.7403973,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

59

Galveston Historical Foundation | Open Energy Information  

Open Energy Info (EERE)

Historical Foundation Historical Foundation Jump to: navigation, search Logo: Galveston Historical Foundation Name Galveston Historical Foundation Address 502 20th St. Place Galveston, Texas Zip 77550 Region Texas Area Number of employees 11-50 Year founded 1954 Phone number 409-765-7834 Website http://www.galvestonhistory.or Coordinates 29.3054013°, -94.7900179° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":29.3054013,"lon":-94.7900179,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

60

Load cell  

DOE Patents (OSTI)

A load cell combines the outputs of a plurality of strain gauges to measure components of an applied load. Combination of strain gauge outputs allows measurement of any of six load components without requiring complex machining or mechanical linkages to isolate load components. An example six axis load cell produces six independent analog outputs, each directly proportional to one of the six general load components. 16 figs.

Spletzer, B.L.

1998-12-15T23:59:59.000Z

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Load cell  

DOE Patents (OSTI)

A load cell combines the outputs of a plurality of strain gauges to measure components of an applied load. Combination of strain gauge outputs allows measurement of any of six load components without requiring complex machining or mechanical linkages to isolate load components. An example six axis load cell produces six independent analog outputs which can be combined to determine any one of the six general load components.

Spletzer, Barry L. (Albuquerque, NM)

2001-01-01T23:59:59.000Z

62

Load cell  

DOE Patents (OSTI)

A load cell combines the outputs of a plurality of strain gauges to measure components of an applied load. Combination of strain gauge outputs allows measurement of any of six load components without requiring complex machining or mechanical linkages to isolate load components. An example six axis load cell produces six independent analog outputs, each directly proportional to one of the six general load components.

Spletzer, Barry L. (Albuquerque, NM)

1998-01-01T23:59:59.000Z

63

Commercial equipment loads: End-Use Load and Consumer Assessment Program (ELCAP)  

SciTech Connect

The Office of Energy Resources of the Bonneville Power Administration is generally responsible for the agency's power and conservation resource planning. As associated responsibility which supports a variety of office functions is the analysis of historical trends in and determinants of energy consumption. The Office of Energy Resources' End-Use Research Section operates a comprehensive data collection program to provide pertinent information to support demand-side planning, load forecasting, and demand-side program development and delivery. Part of this on-going program is known as the End-Use Load and Consumer Assessment Program (ELCAP), an effort designed to collect electricity usage data through direct monitoring of end-use loads in buildings. This program is conducted for Bonneville by the Pacific Northwest Laboratory. This report provides detailed information on electricity consumption of miscellaneous equipment from the commercial portion of ELCAP. Miscellaneous equipment includes all commercial end-uses except heating, ventilating, air conditioning, and central lighting systems. Some examples of end-uses covered in this report are office equipment, computers, task lighting, refrigeration, and food preparation. Electricity consumption estimates, in kilowatt-hours per square food per year, are provided for each end-use by building type. The following types of buildings are covered: office, retail, restaurant, grocery, warehouse, school, university, and hotel/motel. 6 refs., 35 figs., 12 tabs.

Pratt, R.G.; Williamson, M.A.; Richman, E.E.; Miller, N.E.

1990-07-01T23:59:59.000Z

64

Independent review of estimated load reductions for PJM's small customer load response pilot project  

E-Print Network (OSTI)

Abbreviations ADDF ALM AMR CSP DOE DR ELRP ETS EWH FERC HVa Curtailment Service Provider (CSP) at PJM’s request. LBNLof load control tests. The CSP collected hourly load data

Heffner, G.; Moezzi, M.; Goldman, C.

2004-01-01T23:59:59.000Z

65

Wavelet-Based Nonlinear Multiscale Decomposition Model for Electricity Load Forecasting  

E-Print Network (OSTI)

ABSTRACT: We propose a wavelet multiscale decomposition based autoregressive approach for the prediction of one-hour ahead ahead load based on historical electricity load data. This approach is based on a multiple resolution decomposition of the signal using the non-decimated or redundant Haar à trous wavelet transform whose advantage is taking into account the asymmetric nature of the time-varying data. There is an additional computational advantage in that there is no need to recompute the wavelet transform (wavelet coefficients) of the full signal if the electricity data (time series) is regularly updated. We assess results produced by this multiscale autoregressive (MAR) method, in both linear and non-linear variants, with single resolution autoregression (AR), multilayer perceptron (MLP), Elman recurrent neural network (ERN) and the general regression neural network (GRNN) models. Results are based on the New South Wales (Australia) electricity load data that is provided by the National Electricity Market

D. Benaouda; F. Murtagh; J. L. Starck; O. Renaud; Universiti Tenaga Nasional; Jalan Kajang-puchong

2005-01-01T23:59:59.000Z

66

historic site award  

Science Conference Proceedings (OSTI)

... Honors 'Historic Site' of NBS Physics Discovery. ... The American Physical Society (APS) has named ... revealed that in certain nuclear processes pairs ...

2011-11-16T23:59:59.000Z

67

ARM - Historical Visitor Statistics  

NLE Websites -- All DOE Office Websites (Extended Search)

and Usage (October 1995 - Present) Historical Visitor Statistics As a national user facility, ARM is required to report facility use for actual visitors and for active user...

68

load data | OpenEI Community  

Open Energy Info (EERE)

51 51 Varnish cache server Home Groups Community Central Green Button Applications Developer Utility Rate FRED: FRee Energy Database More Public Groups Private Groups Features Groups Blog posts Content Stream Documents Discussions Polls Q & A Events Notices My stuff Energy blogs 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142234851 Varnish cache server load data Home Sfomail's picture Submitted by Sfomail(48) Member 17 May, 2013 - 12:03 Commercial and Residential Hourly Load Data Now Available on OpenEI! building load building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL Files: application/zip icon System Advisor Model Tool for Downloading Load Data

69

OpenEI - hourly emission factors  

Open Energy Info (EERE)

http:en.openei.orgdatasetstaxonomyterm4640 en Hourly Energy Emission Factors for Electricity Generation in the United States http:en.openei.orgdatasetsnode488...

70

Electrical and Production Load Factors  

E-Print Network (OSTI)

Load factors are an important simplification of electrical energy use data and depend on the ratio of average demand to peak demand. Based on operating hours of a facility they serve as an important benchmarking tool for the industrial sector. The operating hours of small and medium sized manufacturing facilities are analyzed to identify the most common operating hour or shift work patterns. About 75% of manufacturing facilities fall into expected operating hour patterns with operating hours near 40, 80, 120 and 168 hours/week. Two types of load factors, electrical and production are computed for each shift classification within major industry categories in the U.S. The load factor based on monthly billing hours (ELF) increases with operating hours from about 0.4 for a nominal one shift operation, to about 0.7 for around-the-clock operation. On the other hand, the load factor based on production hours (PLF) shows an inverse trend, varying from about 1.4 for one shift operation to 0.7 for around-the-clock operation. When used as a diagnostic tool, if the PLF exceeds unity, then unnecessary energy consumption may be taking place. For plants operating at 40 hours per week, the ELF value was found to greater than the theoretical maximum, while the PLF value was greater than one, suggesting that these facilities may have significant energy usage outside production hours. The data for the PLF however, is more scattered for plants operating less than 80 hours per week, indicating that grouping PLF data based on operating hours may not be a reasonable approach to benchmarking energy use in industries. This analysis uses annual electricity consumption and demand along with operating hour data of manufacturing plants available in the U.S. Department of Energy’s Industrial Assessment Center (IAC) database. The annual values are used because more desirable monthly data are not available. Monthly data are preferred as they capture the load profile of the facility more accurately. The data there come from Industrial Assessment Centers which employ university engineering students, faculty and staff to perform energy assessments for small to medium-sized manufacturing plants. The nation-wide IAC program is sponsored by the U.S. Department of Energy.

Sen, Tapajyoti

2009-12-01T23:59:59.000Z

71

building load | OpenEI  

Open Energy Info (EERE)

load load Dataset Summary Description This dataset contains hourly load profile data for 16 commercial building types (based off the DOE commercial reference building models) and residential buildings (based off the Building America House Simulation Protocols). This dataset also includes the Residential Energy Consumption Survey (RECS) for statistical references of building types by location. Source Commercial and Residential Reference Building Models Date Released April 18th, 2013 (9 months ago) Date Updated July 02nd, 2013 (7 months ago) Keywords building building demand building load Commercial data demand Energy Consumption energy data hourly kWh load profiles Residential Data Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually

72

Amp-hour counting control for PV hybrid power systems  

SciTech Connect

The performance of an amp-hour (Ah) counting battery charge control algorithm has been defined and tested using the Digital Solar Technologies MPR-9400 microprocessor based PV hybrid charge controller. This work included extensive field testing of the charge algorithm on flooded lead-antimony and valve regulated lead-acid (VRLA) batteries. The test results after one-year have demonstrated that PV charge utilization, battery charge control, and battery state of charge (SOC) has been significantly improved by providing maximum charge to the batteries while limiting battery overcharge to manufacturers specifications during variable solar resource and load periods.

Hund, T.D. [Sandia National Labs., Albuquerque, NM (United States); Thompson, B. [Biri Systems, Ithaca, NY (United States)

1997-06-01T23:59:59.000Z

73

Bradbury Science Museum announces winter opening hours  

NLE Websites -- All DOE Office Websites (Extended Search)

Bradbury Science Museum winter hours Bradbury Science Museum winter hours Bradbury Science Museum announces winter opening hours Museum will be closed on Christmas Day (December 25) and New Year's Day (January 1, 2011). December 21, 2010 Bradbury Science Museum Bradbury Science Museum Contact Communications Office (505) 667-7000 Often called "a window to the Laboratory," the museum annually attracts thousands of visitors from all over the world. LOS ALAMOS, New Mexico, December 21, 2010-Los Alamos National Laboratory's Bradbury Science Museum will be closed on Christmas Day (December 25) and New Year's Day (January 1, 2011). On all other days, the museum will observe regular opening hours: from 10 a.m. to 5 p.m. Tuesdays to Saturdays, and from 1 to 5 p.m. Sundays and Mondays. Often called "a window to the Laboratory," the museum annually attracts

74

Change in historic buildings  

E-Print Network (OSTI)

Change in historic buildings is inevitable. If these changes are not well-managed, the cityscape will be threatened because a city is composed of buildings. A good city should combine both growth and preservation. Controlling ...

Yin, Chien-Ni

1992-01-01T23:59:59.000Z

75

Berkeley Lab: historical Perspective  

NLE Websites -- All DOE Office Websites (Extended Search)

identifies Plutonium: &24;&24; th element on the Periodic Table. Old Town developed for the Manhattan Project fi g u r e 1.7 the historic dome of the 184" cyclotron, now the home of...

76

Manhattan Project Historical Resources  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Energy has developed and made available to the public--in print, online, and on display--a variety of Manhattan Project historical resources. These include histories, websites,...

77

MANHATTAN PROJECT HISTORICAL RESOURCES  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Energy has developed and made available to the public--in print, online, and on display--a variety of Manhattan Project historical resources. These include histories, websites,...

78

Historical Natural Gas Annual 1999  

Gasoline and Diesel Fuel Update (EIA)

1999 The Historical Natural Gas Annual contains historical information on supply and disposition of natural gas at the national, regional, and State level as well as prices at...

79

Historical Monthly Energy Review  

Gasoline and Diesel Fuel Update (EIA)

73-92) 73-92) Distribution Category UC-950 Historical Monthly Energy Review 1973-1992 Energy Information Administration Office of Energy Markets and End Use U.S. Department of Energy Washington, DC 20585 This report was prepared by the Energy Information Administration, the independent statistical and analytical agency within the Department of Energy. The information contained herein should not be construed as advocating or reflecting any policy position of the Department of Energy or any other organization. Historical Monthly Energy Review The Historical Monthly Energy Review (HMER) presents monthly and annual data from 1973 through 1992 on production, consumption, stocks, imports, exports, and prices of the principal energy commodities in the United States. Also included are data on international

80

OpenEI Community - load profile  

Open Energy Info (EERE)

/0 en Commercial and /0 en Commercial and Residential Hourly Load Data Now Available on OpenEI! http://en.openei.org/community/blog/commercial-and-residential-hourly-load-data-now-available-openei <span class=Load data" src="http://en.openei.org/community/files/load_data_figure_small.jpg" style="width:527px; height:285px" title="" />Image source: NREL 

Files: 
application/zip icon

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

An Evaluation of the HVAC Load Potential for Providing Load Balancing Service  

Science Conference Proceedings (OSTI)

This paper investigates the potential of providing aggregated intra-hour load balancing services using heating, ventilating, and air-conditioning (HVAC) systems. A direct-load control algorithm is presented. A temperature-priority-list method is used to dispatch the HVAC loads optimally to maintain consumer-desired indoor temperatures and load diversity. Realistic intra-hour load balancing signals were used to evaluate the operational characteristics of the HVAC load under different outdoor temperature profiles and different indoor temperature settings. The number of HVAC units needed is also investigated. Modeling results suggest that the number of HVACs needed to provide a {+-}1-MW load balancing service 24 hours a day varies significantly with baseline settings, high and low temperature settings, and the outdoor temperatures. The results demonstrate that the intra-hour load balancing service provided by HVAC loads meet the performance requirements and can become a major source of revenue for load-serving entities where the smart grid infrastructure enables direct load control over the HAVC loads.

Lu, Ning

2012-09-30T23:59:59.000Z

82

hourly solar radiation | OpenEI  

Open Energy Info (EERE)

solar radiation solar radiation Dataset Summary Description (Abstract): A need for predicting hourly global radiation exists for many locations particularly in Bangladesh for which measured values are not available and daily values have to be estimated from sunshine data. The CPRG model has been used to predict values of hourly Gh for Dhaka (23.770N, 90.380E), Chittagong (22.270N, 91.820E) and Bogra (24.850N, 89.370E) for = ±7.50, ±22.50, ±37.50, ±52.50, ±67.50, ±82.50 and ±97.50 i.e., for ±1/2, ±3/2, ±5/2, ±7/2, ±9/2, ±11/2, ±13/2 hours before and after solar noon and the computed values for Source Renewable Energy Research Centre Date Released October 22nd, 2003 (11 years ago) Date Updated Unknown Keywords Bangladesh documentation hourly solar radiation SWERA

83

Life of a Six-Hour Hurricane  

Science Conference Proceedings (OSTI)

Hurricane Claudette developed from a weak vortex in 6 h as deep convection shifted from downshear into the vortex center, despite ambient vertical wind shear exceeding 10 m s?1. Six hours later it weakened to a tropical storm, and 12 h after the ...

Kay L. Shelton; John Molinari

2009-01-01T23:59:59.000Z

84

NERSC Edison Phase I Hours Used Report  

NLE Websites -- All DOE Office Websites (Extended Search)

Edison Phase I Hours Used Edison Phase I Hours Used Edison Phase I Hours Used Edison Usage Chart Edison Usage Chart Date Hours Used (in millions) Percent of Maximum Possible (24 hours/day) 06/23/2013 0.226 88.6 06/22/2013 0.239 93.9 06/21/2013 0.248 97.1 06/20/2013 0.240 94.0 06/19/2013 0.233 91.3 06/18/2013 0.245 96.0 06/17/2013 0.251 98.4 06/16/2013 0.243 95.3 06/15/2013 0.245 95.9 06/14/2013 0.246 96.5 06/13/2013 0.240 94.1 06/12/2013 0.128 50.4 06/11/2013 0.215 84.5 06/10/2013 0.225 88.4 06/09/2013 0.228 89.6 06/08/2013 0.225 88.3 06/07/2013 0.121 47.5 06/06/2013 0.223 87.4 06/05/2013 0.250 98.0 06/04/2013 0.234 91.6 06/03/2013 0.218 85.5 06/02/2013 0.246 96.4 06/01/2013 0.230 90.0 05/31/2013 0.215 84.5 05/30/2013 0.212 83.1 05/29/2013 0.223 87.3 05/28/2013 0.237 93.0 05/27/2013 0.226 88.5 05/26/2013 0.229 89.9

85

Analysis of historical residential air-conditioning equipment sizing using monitored data  

SciTech Connect

Monitored data were analyzed to determine whether residential air conditioners in the Pacific Northwest historically have been sized properly to meet or slightly exceed actual cooling requirements. Oversizing air-conditioning equipment results in a loss of efficiency because of increased cycling and also lowers humidity control. On the other hand, the penalty of undersizing air-conditioning equipment may be some loss of comfort during extremely hot weather. The monitored data consist of hourly space-conditioning electrical energy use and internal air temperature data collected during the past 7 years from 75 residences in the Pacific Northwest. These residences are equipped with central air conditioners or heat pumps. The periods with the highest cooling energy use were analyzed for each site. A standard industry sizing methodology was used for each site to determine a sizing estimate. Both the sizing recommendation based on Manual J and peak monitored loads are compared to the capacity of the installed equipment for each site to study how the actual capacity differed from both the estimate of proper sizing and from actual demands. Characteristics of the maximum cooling loads are analyzed here to determine which conditions put the highest demand on the air conditioner. Specifically, internal air temperature data are used to determine when the highest cooling loads occur, at constant thermostat settings or when the thermostat was set down. This analysis of monitored data also provides insight into the extent that occupant comfort may be affected by undersizing air conditioners. The findings of this research indicate that cooling equipment historically has often but not always been oversized beyond industry-recommended levels. However, some occupants in homes with undersized, properly sized, and, in rare occasions, even oversized cooling equipment appear to suffer because the cooling equipment cannot always provide adequate cooling. Key findings are summarized.

Lucas, R.G.

1993-02-01T23:59:59.000Z

86

Load Profiling and Settlement for Retail Markets Methods Assessment Study  

Science Conference Proceedings (OSTI)

Retail electric competition requires estimation of hourly loads for each retail supplier. Load profiling is the means by which loads for customers who do not have hourly metering are accounted for. This report presents an assessment of alternative load profiling and settlement methods for retail electric markets and provides a framework for evaluating costs and benefits of potential improvements to profiling and settlement systems. This report is available only to funders of Program 101A or 101.001. Fund...

1999-06-01T23:59:59.000Z

87

Historic Fuel Standards | OpenEI Community  

Open Energy Info (EERE)

52512 52512 Varnish cache server Home Groups Community Central Green Button Applications Developer Utility Rate FRED: FRee Energy Database More Public Groups Private Groups Features Groups Blog posts Content Stream Documents Discussions Polls Q & A Events Notices My stuff Energy blogs 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142252512 Varnish cache server Historic Fuel Standards Home > Blogs > Graham7781's blog Graham7781's picture Submitted by Graham7781(2002) Super contributor 30 August, 2012 - 15:16 auto fuel efficiency obama standards vehicle White House On Tuesday, Ray Lahood, Secretary of the U.S. Department of Transportation, and Lisa P. Jackson, Environmental Protection Agency Administrator, unveiled the joint effort, along with the Obama Administration, to create

88

Day-Ahead/Hour-Ahead Forecasting for Demand Trading: A Guidebook  

Science Conference Proceedings (OSTI)

Demand trading can be an effective hedge against wholesale power price spikes during times of constraint. However, it also can be a high-risk venture. Profitability depends on reliable demand forecasting. Short-term load forecasting (STLF) can minimize the risks of day-ahead purchasing by providing better predictions at the system level. Additionally, STLF can reduce hour-ahead spot market risks and directly support demand trading by providing more accurate assessments of incremental load reductions from...

2001-12-20T23:59:59.000Z

89

Historic Preservation | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Historic Historic Preservation Historic Preservation 1. What does the Programmatic Agreement on historic preservation entail? DOE staff worked with the Advisory Council on Historic Preservation and the National Conference of State Historic Preservation Officers to complete a prototype Programmatic Agreement (PA). By way of background, the PA will allow flexibility between the States while recognizing that many States have already instituted effective consultation protocols that can be applied to DOE's programs. Through this PA, DOE has taken a categorical approach to activities to streamline reviews, reduce the heavy burden placed on SHPOs, and expedite the obligation of Recovery Act funds. The PA also recognizes the sovereignty of Tribal governments while allowing them

90

Load Control  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Visualization and Controls Peer Review Visualization and Controls Peer Review Load Control for System Reliability and Measurement-Based Stability Assessment Dan Trudnowski, PhD, PE Montana Tech Butte, MT 59701 dtrudnowski@mtech.edu 406-496-4681 October 2006 2 Presentation Outline * Introduction - Goals, Enabling technologies, Overview * Load Control - Activities, Status * Stability Assessment - Activities, Status * Wrap up - Related activities, Staff 3 Goals * Research and develop technologies to improve T&D reliability * Technologies - Real-time load control methodologies - Measurement-based stability-assessment 4 Enabling Technologies * Load control enabled by GridWise technology (e.g. PNNL's GridFriendly appliance) * Real-time stability assessment enabled by Phasor Measurement (PMU) technology 5 Project Overview * Time line: April 18, 2006 thru April 17, 2008

91

G&T adds versatile load management system  

SciTech Connect

Wolverine`s load management system was designed in response to the need to reduce peak demand. The Energy Management System (EMS) prepares short term (seven day) load forecasts, based on a daily peak demand forecst, augmented by a similar day profile based on weather conditions. The software combines the similar day profile with the daily peak demand forecast to yield an hourly load forecast for an entire week. The software uses the accepted load forecast case in many application functions, including interchange scheduling, unit commitment, and transaction evaluation. In real time, the computer updates the accepted forecast hourly, based in actual changes in the weather and load. The load management program executes hourly. The program uses impact curves to calculate a load management strategy that reduces the load forecast below a desired load threshold.

Nickel, J.R.; Baker, E.D.; Holt, J.W.; Chan, M.L.

1995-04-01T23:59:59.000Z

92

Abstract--This paper analyzes a distribution system load time series through autocorrelation coefficient, power spectral density,  

E-Print Network (OSTI)

models [7], [8]. The load model developed in [7] provides different 24-hour load profiles for different seasons. The 24-hour load profile is obtained by a weighted sum of peak loads from different types1 Abstract--This paper analyzes a distribution system load time series through autocorrelation

Bak-Jensen, Birgitte

93

An Optimized Autoregressive Forecast Error Generator for Wind and Load Uncertainty Study  

SciTech Connect

This paper presents a first-order autoregressive algorithm to generate real-time (RT), hour-ahead (HA), and day-ahead (DA) wind and load forecast errors. The methodology aims at producing random wind and load forecast time series reflecting the autocorrelation and cross-correlation of historical forecast data sets. Five statistical characteristics are considered: the means, standard deviations, autocorrelations, and cross-correlations. A stochastic optimization routine is developed to minimize the differences between the statistical characteristics of the generated time series and the targeted ones. An optimal set of parameters are obtained and used to produce the RT, HA, and DA forecasts in due order of succession. This method, although implemented as the first-order regressive random forecast error generator, can be extended to higher-order. Results show that the methodology produces random series with desired statistics derived from real data sets provided by the California Independent System Operator (CAISO). The wind and load forecast error generator is currently used in wind integration studies to generate wind and load inputs for stochastic planning processes. Our future studies will focus on reflecting the diurnal and seasonal differences of the wind and load statistics and implementing them in the random forecast generator.

De Mello, Phillip; Lu, Ning; Makarov, Yuri V.

2011-01-17T23:59:59.000Z

94

Historical Maps Online  

E-Print Network (OSTI)

For 20 years, David Rumsey assembled a collection of more than 150,000 historical maps of the Americas and the world. Motivated by a desire to make his private map collection a free public resource, Rumsey then created an online map library, http://www.davidrumsey.com/, which currently has over 10,000 high resolution images of maps from his collection. He has also built a suite of tools for users to experience and interpret the maps online. These include GIS, which allows users to combine historical maps with modern geospatial data to see change over time. The online map collection can be accessed over the Internet from search engines, library catalogs, GIS databases and many other entry points. Rumsey continues to add new content to the online collection and develops new tools that improve both the user experience and the online library architecture.

Rumsey, David Y.

2005-01-31T23:59:59.000Z

95

Idaho State Historical Society | Open Energy Information  

Open Energy Info (EERE)

Name Idaho State Historical Society Name Idaho State Historical Society Address 2205 Old Penitentiary Road Place Boise, Idaho Zip 83712 Phone number 208-334-2774 Website http://history.idaho.gov/ Coordinates 43.6012441°, -116.1660202° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":43.6012441,"lon":-116.1660202,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

96

Historic Marker.doc  

NLE Websites -- All DOE Office Websites (Extended Search)

your email here@srs.gov your email here@srs.gov Historic Tank Marker Donated to Savannah River Site Archives AIKEN, S.C. (February 6, 2013) - The 1997 marker commemorating the operational closure of the nation's first Cold War era nuclear waste tank has been donated by Savannah River Remediation (SRR) to the Savannah River Cold War Artifact Collection. In accepting the marker, Caroline Bradford, curator of the Savannah River Cold War

97

Hour-by-Hour Cost Modeling of Optimized Central Wind-Based Water Electrolysis Production  

NLE Websites -- All DOE Office Websites (Extended Search)

Hour-by-Hour Cost Hour-by-Hour Cost Modeling of Optimized Central Wind-Based Water Electrolysis Production Genevieve Saur (PI), Chris Ainscough (Presenter), Kevin Harrison, Todd Ramsden National Renewable Energy Laboratory January 17 th , 2013 This presentation does not contain any proprietary, confidential, or otherwise restricted information 2 Acknowledgements * This work was made possible by support from the U.S. Department of Energy's Fuel Cell Technologies Office within the Office of Energy Efficiency and Renewable Energy (EERE). http://www.eere.energy.gov/topics/hydrogen_fuel_cells.html * NREL would like to thank our DOE Technology Development Managers for this project, Sara Dillich, Eric Miller, Erika Sutherland, and David Peterson. * NREL would also like to acknowledge the indirect

98

LOADING DEVICE  

DOE Patents (OSTI)

A device is presented for loading or charging bodies of fissionable material into a reactor. This device consists of a car, mounted on tracks, into which the fissionable materials may be placed at a remote area, transported to the reactor, and inserted without danger to the operating personnel. The car has mounted on it a heavily shielded magazine for holding a number of the radioactive bodies. The magazine is of a U-shaped configuration and is inclined to the horizontal plane, with a cap covering the elevated open end, and a remotely operated plunger at the lower, closed end. After the fissionable bodies are loaded in the magazine and transported to the reactor, the plunger inserts the body at the lower end of the magazine into the reactor, then is withdrawn, thereby allowing gravity to roll the remaining bodies into position for successive loading in a similar manner.

Ohlinger, L.A.

1958-10-01T23:59:59.000Z

99

DOE Awards Over a Billion Supercomputing Hours to Address Scientific...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Over a Billion Supercomputing Hours to Address Scientific Challenges DOE Awards Over a Billion Supercomputing Hours to Address Scientific Challenges January 26, 2010 - 12:00am...

100

DOE's Office of Science Awards 95 Million Hours of Supercomputing...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

95 Million Hours of Supercomputing Time to Advance Research in Science, Academia and Industry DOE's Office of Science Awards 95 Million Hours of Supercomputing Time to Advance...

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Historical Natural Gas Annual 1999  

Gasoline and Diesel Fuel Update (EIA)

1999 1999 The Historical Natural Gas Annual contains historical information on supply and disposition of natural gas at the national, regional, and State level as well as prices at selected points in the flow of gas from the wellhead to the burner-tip. Data include production, transmission within the United States, imports and exports of natural gas, underground storage activities, and deliveries to consumers. The publication presents historical data at the national level for 1930-1999 and detailed annual historical information by State for 1967-1999. The Historical Natural Gas Annual tables are available as self-extracting executable files in ASCII TXT or CSV file formats. Tables 1-3 present annual historical data at the national level for 1930-1999. The remaining tables contain detailed annual historical information, by State, for 1967-1999. Please read the file entitled READMEV2 for a description and documentation of information included in this file.

102

Incremental cooling load determination for passive direct gain heating systems  

DOE Green Energy (OSTI)

This paper examines the applicability of the National Association of Home Builders (NAHB) full load compressor hour method for predicting the cooling load increase in a residence, attributable to direct gain passive heating systems. The NAHB method predictions are compared with the results of 200 hour-by-hour simulations using BLAST and the two methods show reasonable agreement. The degree of agreement and the limitations of the NAHB method are discussed.

Sullivan, P.W.; Mahone, D.; Fuller, W.; Gruber, J.; Kammerud, R.; Place, W.; Andersson, B.

1981-05-01T23:59:59.000Z

103

Advisory Council on Historic Preservation | Open Energy Information  

Open Energy Info (EERE)

on Historic Preservation on Historic Preservation Jump to: navigation, search Logo: Advisory Council on Historic Preservation Name Advisory Council on Historic Preservation Address 1100 Pennsylvania Avenue NW, Suite 803 Place Washington, District of Columbia Zip 200004 Website http://www.achp.gov/index.html Coordinates 38.893686°, -77.0276442° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":38.893686,"lon":-77.0276442,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

104

Montana State Historic Preservation Office | Open Energy Information  

Open Energy Info (EERE)

Montana State Historic Preservation Office Montana State Historic Preservation Office Jump to: navigation, search Logo: Montana State Historic Preservation Office Name Montana State Historic Preservation Office Address 1410 Eighth Avenue Place Helena, Montana Zip 59620 Phone number 406-444-7715 Website http://mhs.mt.gov/shpo/ Coordinates 46.588015°, -112.015825° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":46.588015,"lon":-112.015825,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

105

Historical Interest Rates  

NLE Websites -- All DOE Office Websites (Extended Search)

Current and Historical Interest Rates Current and Historical Interest Rates The table lists interest rates, from the project's inception through the present, for all projects with repayment supervised by the CRSP MC. The latest available interest rate is used for all future interest rate calculations. The Amistad-Falcon, Collbran, Provo River, and Rio Grande Projects are all assigned the average daily "Yield Rate" calculated by the U.S. Treasury, on an annual basis, for Treasury bonds having terms of 15 years or more remaining to maturity. The calculated yield rate is rounded to the nearest one-eighth of one percent. The yield rate is based upon the bond's interest rate, as well as its market value. The Colorado River Storage Project and its participating projects, Dolores and Seedskadee, are assigned the average daily "Coupon Rate," annualized for the same U.S. Treasury bonds used in "Yield Rate" calculations. The coupon rate is the interest rate that the bond carries upon its face.

106

Background - Historical Perspective  

NLE Websites -- All DOE Office Websites (Extended Search)

Historical Perspective Historical Perspective The Highway Trust Fund (HTF) was established in 1956 (Public Law 84-627) to ensure a dependable source of Federal funding to support highway programs. Prior to 1956, motor fuel and vehicle taxes went to the General Fund; although highway funding was provided from the General Fund, there was no relationship between fuel tax receipts and highway funding. Since 1956, legislation has periodically extended taxation of motor fuels and the HTF. The Transportation Equity Act for the 21st Century (TEA-21) extended the HTF through September 30, 2005. The HTF currently contains two accounts: the Highway Account and the Mass Transit Account; this document only concerns funds in the Highway Account. The income and outlays for transportation have increased steadily over time. The closing balance of funds in the Highway Account of the HTF remained at around $10 billion from 1983 through 1995. In 2000, the closing balance in the Highway Account was over $22.5 billion. It is necessary to maintain a balance of funds in the HTF to be able to meet unpaid commitments. This balance is not surplus funds because the HTF functions as a reimbursable program and must maintain funds for reimbursing obligations. The closing balance (income - outlays = closing balance) is shown in the following chart for 1957 through 2000 (the latest available data).

107

LOADED WAVEGUIDES  

DOE Patents (OSTI)

>Loaded waveguides are described for the propagation of electromagnetic waves with reduced phase velocities. A rectangular waveguide is dimensioned so as to cut-off the simple H/sub 01/ mode at the operating frequency. The waveguide is capacitance loaded, so as to reduce the phase velocity of the transmitted wave, by connecting an electrical conductor between directly opposite points in the major median plane on the narrower pair of waveguide walls. This conductor may take a corrugated shape or be an aperature member, the important factor being that the electrical length of the conductor is greater than one-half wavelength at the operating frequency. Prepared for the Second U.N. International ConferThe importance of nuclear standards is duscussed. A brief review of the international callaboration in this field is given. The proposal is made to let the International Organization for Standardization (ISO) coordinate the efforts from other groups. (W.D.M.)

Mullett, L.B.; Loach, B.G.; Adams, G.L.

1958-06-24T23:59:59.000Z

108

Historic Preservation | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Act General Questions Eligibility Buy American Davis Bacon Historic Preservation Appropriations Questions Procurement Other Topics Sign Up for GC Updates Jobs and Internships All...

109

Topic modeling on historical newspapers  

Science Conference Proceedings (OSTI)

In this paper, we explore the task of automatic text processing applied to collections of historical newspapers, with the aim of assisting historical research. In particular, in this first stage of our project, we experiment with the use of topical models ...

Tze-I Yang; Andrew J. Torget; Rada Mihalcea

2011-06-01T23:59:59.000Z

110

BNL | Center for Functional Nanomaterials Hours of Operation  

NLE Websites -- All DOE Office Websites (Extended Search)

CFN Hours of Operation CFN Hours of Operation Normal working hours at the CFN are 8 a.m. to 6 p.m. Working Outside of Normal Hours CFN scientific and technical personnel, as well as external users, may need to work outside of normal operating hours, during which time support is limited and many colleagues may not be around. Therefore, working outside the 8 a.m. to 6 p.m. envelope on weekdays, or anytime on weekends and holidays, requires special precautions, especially if working in a laboratory. CFN users are expected to work at the CFN during normal working hours. Users with extensive experience working at the CFN may be granted permission by the appropriate facility leader and ES&H Coordinator to work after hours. Users first must complete the Request to Work After-Hours at

111

Results of the 1000 Hour Rotary Microfilter Endurance Test  

Stellite on Nitronic 60. 8 SRNL-L3100-2010-00229 Rotary Microfilter 1000 Hour Test Flux Data for 1000 Hour Test 0 1 2 3 4 5 6 0 100 200 300 400 500 ...

112

Day-Ahead/Hour-Ahead Forecasting for Demand Trading: A Guidebook  

Science Conference Proceedings (OSTI)

Download report 1006016 for FREE. Demand trading can be an effective hedge against wholesale power price spikes during times of constraint. However, it also can be a high-risk venture. Profitability depends on reliable demand forecasting. Short-term load forecasting (STLF) can minimize the risks of day-ahead purchasing by providing better predictions at the system level. Additionally, STLF can reduce hour-ahead spot market risks and directly support demand trading by providing more accurate assessments o...

2001-12-20T23:59:59.000Z

113

Reliability analysis of solar photovoltaic system using hourly mean solar radiation data  

Science Conference Proceedings (OSTI)

This paper presents the hourly mean solar radiation and standard deviation as inputs to simulate the solar radiation over a year. Monte Carlo simulation (MCS) technique is applied and MATLAB program is developed for reliability analysis of small isolated power system using solar photovoltaic (SPV). This paper is distributed in two parts. Firstly various solar radiation prediction methods along with hourly mean solar radiation (HMSR) method are compared. The comparison is carried on the basis of predicted electrical power generation with actual power generated by SPV system. Estimation of solar photovoltaic power using HMSR method is close to the actual power generated by SPV system. The deviation in monsoon months is due to the cloud cover. In later part of the paper various reliability indices are obtained by HMSR method using MCS technique. Load model used is IEEE-RTS. Reliability indices, additional load hours (ALH) and additional power (AP) reduces exponentially with increase in load indicates that a SPV source will offset maximum fuel when all of its generated energy is utilized. Fuel saving calculation is also investigated. Case studies are presented for Sagardeep Island in West Bengal state of India. (author)

Moharil, Ravindra M. [Department of Electrical Engineering, Yeshwantrao Chavan College of Engineering, Nagpur, Maharashtra (India); Kulkarni, Prakash S. [Department of Electrical Engineering, Visvesvaraya National Institute of Technology, South Ambazari Road, Nagpur 440011, Maharashtra (India)

2010-04-15T23:59:59.000Z

114

Definition: Base Load | Open Energy Information  

Open Energy Info (EERE)

Load Load Jump to: navigation, search Dictionary.png Base Load The minimum amount of electric power delivered or required over a given period at a constant rate.[1] View on Wikipedia Wikipedia Definition Baseload (also base load, or baseload demand) is the minimum amount of power that a utility or distribution company must make available to its customers, or the amount of power required to meet minimum demands based on reasonable expectations of customer requirements. Baseload values typically vary from hour to hour in most commercial and industrial areas. Related Terms electricity generation, power, smart grid References ↑ Glossary of Terms Used in Reliability Standards An in Like Like You like this.Sign Up to see what your friends like. line Glossary Definition Retrieved from

115

Regional load curve models: specification and estimation of the DRI Model. Final report. [Forecasts of electric loads in 32 US regions  

SciTech Connect

The DRI Model of hourly load curves is developed in this report. The model is capable of producing long-term forecasts for 32 US regions. These regions were created by aggregating hourly system load data from 146 electric utilities. These utilities supply approximately 95% of all electricity consumed in the continental US. The model forecasts electricity demands for each hour of the year for each of the 32 regions. Model output includes forecasts of peak demands, megawatt hour demands, load factors, and load duration curves. The DRI Model is estimated in two stages. In the first stage, for each region and month, hourly electricity demands are parameterized into load components representing the effects of lifestyles and weather on regional loads through a time-series model. In the second stage, the variation in these parameterized load components across months and regions is modeled econometrically in terms of energy prices, income levels, appliance saturation rates, and other variables. The second-stage models are essentially models of electricity demand which are estimated using estimated first-stage parameters as dependent variables, instead of observed demands. Regional price and income demand elasticities are implied by the second-stage models. Moreover, since the dependent variables refer to particular hours of the day, these estimated elasticities are hour-specific. (Since prices did not vary over the day in years when hourly load data were available, hour-to-hour, cross-price elasticities were not estimated.) Integrated system hourly load forecasts are obtained combining the influences of individual customer classes. Finally, approximate customer class hourly load shapes can be produced for each region, though these series may be useful only in research endeavors since they lack the precision available through survey methods.

Platt, H.D.; Einhorn, M.A.; Ignelzi, P.C.; Poirier, D.J.

1981-01-01T23:59:59.000Z

116

Hawaii Department of Land and Natural Resources Historic Preservation  

Open Energy Info (EERE)

Historic Preservation Historic Preservation Division Jump to: navigation, search Name Hawaii Department of Land and Natural Resources Historic Preservation Division Address Kakuhihewa Building 601 Kamokila Blvd., Suite 555 Kakuhihewa Building 601 Kamokila Blvd., Suite 555 Place Honolulu, Hawaii Zip 96707 Website http://hawaii.gov/dlnr/shpd/ Coordinates 21.331284°, -158.083885° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":21.331284,"lon":-158.083885,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

117

PIA - Historical Data for Legal Organizations | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Historical Data for Legal Organizations PIA - Historical Data for Legal Organizations PIA - Historical Data for Legal Organizations PIA - Historical Data for Legal Organizations...

118

Historical Procurement Information- by Location  

Energy.gov (U.S. Department of Energy (DOE))

Small business contracing is difficult to navigate. We've built the Small Business Opportunities Tool to identify historical records of what the Department of Energy has purchased, which you can...

119

ASP Historic Site 2011 | Brookhaven National Lab  

NLE Websites -- All DOE Office Websites (Extended Search)

BNL Home APS Historic Site 2011 The American Physical Society (APS) will commemorate Brookhaven National Laboratory as a historic site in the advancement of the field of physics....

120

Department of Energy Research Opportunities for Historically...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Department of Energy Research Opportunities for Historically Black Colleges and Universities Department of Energy Research Opportunities for Historically Black Colleges and...

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Improving Forecasting: A plea for historical retrospectives  

NLE Websites -- All DOE Office Websites (Extended Search)

Improving Forecasting: A plea for historical retrospectives Title Improving Forecasting: A plea for historical retrospectives Publication Type Journal Article Year of Publication...

122

Historical Natural Gas Annual - 1930 Through 2000  

Annual Energy Outlook 2012 (EIA)

2000 The Historical Natural Gas Annual contains historical information on supply and disposition of natural gas at the national, regional, and State level as well as prices at...

123

Forecasting distribution system loads using curve shape clustering  

SciTech Connect

Trending using curve fitting to past small area load growth is an economical but not highly accurate method of forecasting loads for distribution planning. A new trending method uses clustering of historical load at the small area level as the forecast algorithm. This new method has significant performance advantages over normal curve fit methods and can be implemented in 16 bit integer arithmetic on most computers. The method and test results are discussed in detail.

Willis, H.L.; Northcote-Green, J.E.D.; Schauer, A.E.; Vismor, T.D.

1983-04-01T23:59:59.000Z

124

Peak load management: Potential options  

SciTech Connect

This report reviews options that may be alternatives to transmission construction (ATT) applicable both generally and at specific locations in the service area of the Bonneville Power Administration (BPA). Some of these options have potential as specific alternatives to the Shelton-Fairmount 230-kV Reinforcement Project, which is the focus of this study. A listing of 31 peak load management (PLM) options is included. Estimated costs and normalized hourly load shapes, corresponding to the respective base load and controlled load cases, are considered for 15 of the above options. A summary page is presented for each of these options, grouped with respect to its applicability in the residential, commercial, industrial, and agricultural sectors. The report contains comments on PLM measures for which load shape management characteristics are not yet available. These comments address the potential relevance of the options and the possible difficulty that may be encountered in characterizing their value should be of interest in this investigation. The report also identifies options that could improve the efficiency of the three customer utility distribution systems supplied by the Shelton-Fairmount Reinforcement Project. Potential cogeneration options in the Olympic Peninsula are also discussed. These discussions focus on the options that appear to be most promising on the Olympic Peninsula. Finally, a short list of options is recommended for investigation in the next phase of this study. 9 refs., 24 tabs.

Englin, J.E.; De Steese, J.G.; Schultz, R.W.; Kellogg, M.A.

1989-10-01T23:59:59.000Z

125

Low-cost load research for electric utilities  

Science Conference Proceedings (OSTI)

Golden Valley Electric Association (GVEA) developed two pragmatic approaches to meet most load-research objectives at a substantially lower cost than would be incurred with traditional techniques. GVEA serves three customer classes, with most of its load in the Fairbanks area. GVEA's new approaches simulate load curves for individual customer classes to the degree necessary to meet most load-research objectives for the utility, including applications to cost-of-service analysis, rate design, demand-side management, and load forecasting. These approaches make class load-shape information available to utilities that cannot otherwise afford to develop such data. Although the two approaches were developed for a small utility, they are likely to work at least as well for medium and large utilities. The first approach simulates class curves by combining load data from system feeders with information on customer mix and energy usage. GVEA's supervisory control and data acquisition system gives hourly data on feeder loads, and its billing database provides the number of customers and kilowatt-hour usage by customer class on each feeder. The second approach enhances load-research results by redefining target parameters. Data from several like-hours are used to calculate substitutes for the parameters traditionally defined from single-hour data points. The precision of peak responsibility estimates, for example, can be improved if several of the highest hourly demands in a given time period are used rather than the single highest hourly demand. Arguably, use of several highest hourly demands can also improve the reliability of the allocation of responsibility.

Gray, D.A.; Butcher, M.

1994-08-01T23:59:59.000Z

126

Hospital Triage in First Hours After Nuclear or Radiological...  

NLE Websites -- All DOE Office Websites (Extended Search)

Hospital Triage in the First 24 Hours after a Nuclear or Radiological Disaster Medical professionals with the Radiation Emergency Assistance CenterTraining Site (REACTS) at the...

127

Delayed Start or Cancellation of Business Hours | Argonne National...  

NLE Websites -- All DOE Office Websites (Extended Search)

Twitter Delayed Start or Cancellation of Business Hours Winter Road Closings Winter Weather FAQs Westgate Alternate Routes Reporting IllegalUnethical Activity Working Remotely...

128

BIOLOGY 650 (credit 2 hours) Animal Physiology LABORATORY  

E-Print Network (OSTI)

-neuron communication through electrical and chemical synapses will be examined in live preparations. The historical will have their point total for the course pro-rated. Unexcused absences from an exam will result in a score

Cooper, Robin L.

129

Historical Natural Gas Annual - Energy Information Administration  

U.S. Energy Information Administration (EIA)

Historical Natural Gas Annual. 1996: Published October 1997: 1997: Published October 1998: 1998: Published October 1999

130

Weatherization and Intergovernmental Program: Historic Preservation  

NLE Websites -- All DOE Office Websites (Extended Search)

Program Guidance Program Guidance Site Map Printable Version Share this resource Send a link to Weatherization and Intergovernmental Program: Historic Preservation to someone by E-mail Share Weatherization and Intergovernmental Program: Historic Preservation on Facebook Tweet about Weatherization and Intergovernmental Program: Historic Preservation on Twitter Bookmark Weatherization and Intergovernmental Program: Historic Preservation on Google Bookmark Weatherization and Intergovernmental Program: Historic Preservation on Delicious Rank Weatherization and Intergovernmental Program: Historic Preservation on Digg Find More places to share Weatherization and Intergovernmental Program: Historic Preservation on AddThis.com... Closeout Guidance Recovery Act Monitoring & Reporting

131

How and why distribution loads vary  

SciTech Connect

Because the maximum-use rates of gas customers having differing appliance combinations do not coincide, a distribution system's peak-hour flow rate depends on the relative proportions of the load contributed by the appliances of all the different types of residential, commercial, and industrial customers. The maximum load on Central Hudson's distribution system coincides with the maximum hourly gas flow rate for all residential space-heating purposes; however, Central Hudson analyzes the peak-hour load of its commercial and industrial customers individually. The gas-system sendout presented as a sendout-duration curve is a convenient way to show how these various loads determine gas requirements and to compare the economics of alternative supply methods. The sendout-duration curve consists of long-term weather data plotted against time intervals of 1-365 days. If the threshold temperature and the heating load per degree-day are known, the curve allows the calculation of both normal and design annual peakshaving quantities.

Haber, D.P.

1980-01-01T23:59:59.000Z

132

Identifying Challenging Operating Hours for Solar Intergration in the NV Energy System  

Science Conference Proceedings (OSTI)

Abstract-- In this paper, the ability of the Nevada (NV) Energy generation fleet to meet its system balancing requirements under different solar energy penetration scenarios is studied. System balancing requirements include capacity, ramp rate, and ramp duration requirements for load following and regulation. If, during some operating hours, system capability is insufficient to meet these requirements, there is certain probability that the balancing authority’s control and reliability performance can be compromised. These operating hours are considered as “challenging” hours. Five different solar energy integration scenarios have been studied. Simulations have shown that the NV Energy system will be potentially able to accommodate up to 942 MW of solar photovoltaic (PV) generation. However, the existing generation scheduling procedure should be adjusted to make it happen. Fast-responsive peaker units need to be used more frequently to meet the increasing ramping requirements. Thus, the NV Energy system operational cost can increase. Index Terms—Solar Generation, Renewables Integration, Balancing Process, Load Following, Regulation.

Etingov, Pavel V.; Lu, Shuai; Guo, Xinxin; Ma, Jian; Makarov, Yuri V.; Chadliev, Vladimir; Salgo, Richard

2012-05-09T23:59:59.000Z

133

Optimizing hourly hydro operations at the Salt Lake City Area integrated projects  

DOE Green Energy (OSTI)

The Salt Lake City Area (SLCA) office of the Western Area Power Administration (Western) is responsible for marketing the capacity and energy generated by the Colorado Storage, Collbran, and Rio Grande hydropower projects. These federal resources are collectively called the Salt Lake City Area Integrated Projects (SLCA/IP). In recent years, stringent operational limitations have been placed on several of these hydropower plants including the Glen Canyon Dam, which accounts for approximately 80% of the SLCA/IP resources. Operational limitations on SLCA/IP hydropower plants continue to evolve as a result of decisions currently being made in the Glen Canyon Dam Environmental Impact Statement (EIS) and the Power Marketing EIS. To analyze a broad range of issues associated with many possible future operational restrictions, Argonne National Laboratory (ANL), with technical assistance from Western has developed the Hydro LP (Linear Program) Model. This model simulates hourly operations at SLCA/IP hydropower plants for weekly periods with the objective of maximizing Western`s net revenues. The model considers hydropower operations for the purpose of serving SLCA firm loads, loads for special projects, Inland Power Pool (IPP) spinning reserve requirements, and Western`s purchasing programs. The model estimates hourly SLCA/IP generation and spot market activities. For this paper, hourly SLCA/IP hydropower plant generation is simulated under three operational scenarios and three hydropower conditions. For each scenario an estimate of Western`s net revenue is computed.

Veselka, T.D.; Hamilton, S. [Argonne National Lab., IL (United States); McCoy, J. [Western Area Power Administration, Salt Lake City, UT (United States)

1995-06-01T23:59:59.000Z

134

Accurate Short Term Load Forecasting for an ESKOM Major Distribution Region in South Africa: An Application of EPRI ANNSTLF  

Science Conference Proceedings (OSTI)

ANNSTLF (Artificial Neural Network Short-term Load Forecaster), developed by EPRI, is a Microsoft Windows-based neural-network load forecasting software that uses historical load and weather parameters to predict future load values. The software requires customization for each utility. This project involved customizing ANNSTLF for the Eastern Region of the South African energy company ESKOM.

2005-09-27T23:59:59.000Z

135

Historical Resources | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Resources Resources Historical Resources Historical Resources The Department of Energy maintains and makes accessible to the general public a wide variety of historical resources. These include published and online histories of the Department and its predecessor agencies and records, exhibits, museums, and tours available online and at various locations both within and outside the Department. The Department's Office of History and Heritage Resources (OHHR) serves as the institutional memory for the Department. Overviews of the Department produced by OHHR include the online only A Brief History of the Department of Energy and the more in-depth Department of Energy Timeline as well as the published Department of Energy, 1977-1994: A Summary History. The Department is the lineal descendent of several predecessor agencies,

136

Periodic load balancing  

Science Conference Proceedings (OSTI)

Multiprocessor load balancing aims to improve performance by moving jobs from highly loaded processors to more lightly loaded processors. Some schemes allow only migration of new jobs upon arrival, while other schemes allow migration of ... Keywords: heavy traffic diffusion approximations, load balancing, periodic load balancing, reflected Brownian motion, resource sharing, transient behavior

Gísli Hjálmtýsson; Ward Whitt

1998-06-01T23:59:59.000Z

137

NV Energy Large-Scale Photovoltaic Integration Study: Intra-Hour Dispatch and AGC Simulation  

SciTech Connect

The uncertainty and variability with photovoltaic (PV) generation make it very challenging to balance power system generation and load, especially under high penetration cases. Higher reserve requirements and more cycling of conventional generators are generally anticipated for large-scale PV integration. However, whether the existing generation fleet is flexible enough to handle the variations and how well the system can maintain its control performance are difficult to predict. The goal of this project is to develop a software program that can perform intra-hour dispatch and automatic generation control (AGC) simulation, by which the balancing operations of a system can be simulated to answer the questions posed above. The simulator, named Electric System Intra-Hour Operation Simulator (ESIOS), uses the NV Energy southern system as a study case, and models the system’s generator configurations, AGC functions, and operator actions to balance system generation and load. Actual dispatch of AGC generators and control performance under various PV penetration levels can be predicted by running ESIOS. With data about the load, generation, and generator characteristics, ESIOS can perform similar simulations and assess variable generation integration impacts for other systems as well. This report describes the design of the simulator and presents the study results showing the PV impacts on NV Energy real-time operations.

Lu, Shuai; Etingov, Pavel V.; Meng, Da; Guo, Xinxin; Jin, Chunlian; Samaan, Nader A.

2013-01-02T23:59:59.000Z

138

Enhancements to ANNSTLF, EPRI's Short Term Load Forecaster  

Science Conference Proceedings (OSTI)

Reliable hourly load forecasts are important to electric utilities, power marketers, energy service providers, and independent system operators. To meet this need, EPRI's Artificial Neural Net Short Term Load Forecaster (ANNSTLF), which is already implemented at more than thirty-five utilities, was recently enhanced for greater accuracy and user friendliness.

1997-12-08T23:59:59.000Z

139

Report of 1,000 Hour Catalyst Longevity Evaluation  

DOE Green Energy (OSTI)

This report presents the results of a 1,000 hour, high-pressure, catalyst longevity test for the decomposition of concentrated sulfuric acid. The reaction is used for both the sulfur-iodine (S-I) cycle and hybrid sulfur cycle. By the time of the delivery date of April 17, 2009, for project milestone no. 2NIN07TC050114, the 1% Pt/TiO2 catalyst had been in the reaction environment for 658 hours. During the first 480 hours of testing, the catalyst activity provided stable, near-equilibrium yields of 46.8% SO2 and 22.8% O2. However, product yields declined at sample exposure times >480 hours. At 658 hours of operation, catalyst activity (based on oxygen yield) declined to 57% relative to the stable period of catalyst activity. Thus, as of April 17, this catalyst did not provide the desired stability level of <10% degradation per 1,000 hours. The experiment was terminated on April 27, after 792 hours, when a fitting failed and the catalyst was displaced from the reactor such that the sample could not be recovered. Oxygen conversion at the end of the experiment was 12.5% and declining, suggesting that at that point, catalyst activity had decreased to 54% of the initial level.

Daniel M. Ginosar

2009-06-01T23:59:59.000Z

140

Development of an Hourly Optimization Tool for Renewable Energy Systems  

SciTech Connect

An hourly optimization tool is developed to select and size renewable energy (RE) systems to meet the energy needs for various federal facilities. The optimization is based on life cost analysis of various RE technologies including wind and PV systems. The developed hourly optimization tool is used to evaluate the cost-effectiveness of RE technologies using complex energy and demand charges such time-of-use (TOU) rates. The paper compares results obtained using hourly analysis instead of annual based calculations to optimize the sizing of RE systems for residential, commercial, and industrial facilities in three representative US climates.

Lee, C.; Walker, A.; Krarti, M.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Colorado Office of Archaeology and Historic Preservation | Open Energy  

Open Energy Info (EERE)

Colorado Office of Archaeology and Historic Preservation Colorado Office of Archaeology and Historic Preservation Jump to: navigation, search Logo: Office of Archaeology and Historic Preservation Name Office of Archaeology and Historic Preservation Address 1200 Broadway Place Denver, Colorado Zip 80208 Year founded 1879 Phone number 303-447-8679 Website http://www.historycolorado.org Coordinates 39.7352967°, -104.987378° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":39.7352967,"lon":-104.987378,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

142

California State Historic Preservation Officer | Open Energy Information  

Open Energy Info (EERE)

California State Historic Preservation Officer California State Historic Preservation Officer Jump to: navigation, search Logo: California State Historic Preservation Officer Name California State Historic Preservation Officer Address Dept. of Parks and Recreation, 1416 9th Street Place Sacramento, California Zip 95814 Phone number 800-777-0369 Website http://ohp.parks.ca.gov/?page_ Coordinates 38.575523°, -121.497588° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":38.575523,"lon":-121.497588,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

143

A Quality Assurance System for Canadian Hourly Pressure Data  

Science Conference Proceedings (OSTI)

In this study a comprehensive quality assurance (QA) system, which includes the hydrostatic check combined with a statistical homogeneity test, is designed and applied to hourly pressure records (for 1953–2002) from 761 Canadian stations, to ...

Hui Wan; Xiaolan L. Wang; Val R. Swail

2007-11-01T23:59:59.000Z

144

Team Surpasses 1 Million Hours Safety Milestone | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Team Surpasses 1 Million Hours Safety Milestone Team Surpasses 1 Million Hours Safety Milestone Team Surpasses 1 Million Hours Safety Milestone October 30, 2013 - 12:00pm Addthis The Separations Process Research Unit Demolition Project Safety Committee meets regularly with employees and supervisors to discuss safety issues and reinforce safe work habits. The Separations Process Research Unit Demolition Project Safety Committee meets regularly with employees and supervisors to discuss safety issues and reinforce safe work habits. NISKAYUNA, N.Y. - Vigilance and dedication to safety led the EM program's disposition project team at the Separations Process Research Unit (SPRU) to achieve a milestone of one million hours - over two-and-a-half-years - without injury or illness resulting in time away from work.

145

Team Surpasses 1 Million Hours Safety Milestone | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Team Surpasses 1 Million Hours Safety Milestone Team Surpasses 1 Million Hours Safety Milestone Team Surpasses 1 Million Hours Safety Milestone October 30, 2013 - 12:00pm Addthis The Separations Process Research Unit Demolition Project Safety Committee meets regularly with employees and supervisors to discuss safety issues and reinforce safe work habits. The Separations Process Research Unit Demolition Project Safety Committee meets regularly with employees and supervisors to discuss safety issues and reinforce safe work habits. NISKAYUNA, N.Y. - Vigilance and dedication to safety led the EM program's disposition project team at the Separations Process Research Unit (SPRU) to achieve a milestone of one million hours - over two-and-a-half-years - without injury or illness resulting in time away from work.

146

DOE Awards Over a Billion Supercomputing Hours to Address Scientific  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Over a Billion Supercomputing Hours to Address Over a Billion Supercomputing Hours to Address Scientific Challenges DOE Awards Over a Billion Supercomputing Hours to Address Scientific Challenges January 26, 2010 - 12:00am Addthis Washington, DC. - The U.S. Department of Energy announced today that approximately 1.6 billion supercomputing processor hours have been awarded to 69 cutting-edge research projects through the Innovative and Novel Computational Impact on Theory and Experiment (INCITE) program. The INCITE program provides powerful resources to enable scientists and engineers to conduct cutting-edge research in just weeks or months rather than the years or decades needed previously. This facilitates scientific breakthroughs in areas such as climate change, alternative energy, life sciences, and materials science.

147

DOE Awards Over a Billion Supercomputing Hours to Address Scientific  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE Awards Over a Billion Supercomputing Hours to Address DOE Awards Over a Billion Supercomputing Hours to Address Scientific Challenges DOE Awards Over a Billion Supercomputing Hours to Address Scientific Challenges January 26, 2010 - 12:00am Addthis Washington, DC. - The U.S. Department of Energy announced today that approximately 1.6 billion supercomputing processor hours have been awarded to 69 cutting-edge research projects through the Innovative and Novel Computational Impact on Theory and Experiment (INCITE) program. The INCITE program provides powerful resources to enable scientists and engineers to conduct cutting-edge research in just weeks or months rather than the years or decades needed previously. This facilitates scientific breakthroughs in areas such as climate change, alternative energy, life

148

Global Solar Radiation Estimation from Relative Sunshine Hours in Italy  

Science Conference Proceedings (OSTI)

We examine the existing measurements of global solar radiation and sunshine duration for Italy, and evaluate the errors made in estimating global solar radiation from sunshine hours measurements. We find that the Ångstrom–Black linear relation in ...

A. Andretta; B. Bartoli; B. Coluzzi; V. Cuomo; M. Francesca; C. Serio

1982-10-01T23:59:59.000Z

149

Airport quotas and peak hour pricing : theory and practice  

E-Print Network (OSTI)

This report examines the leading theoretical studies not only of airport peak-hour pricing but also of the congestion costs associated with airport delays and presents a consistent formulation of both. The report also ...

Odoni, Amedeo R.

1976-01-01T23:59:59.000Z

150

An Hourly Assimilation–Forecast Cycle: The RUC  

Science Conference Proceedings (OSTI)

The Rapid Update Cycle (RUC), an operational regional analysis–forecast system among the suite of models at the National Centers for Environmental Prediction (NCEP), is distinctive in two primary aspects: its hourly assimilation cycle and its use ...

Stanley G. Benjamin; Dezsö Dévényi; Stephen S. Weygandt; Kevin J. Brundage; John M. Brown; Georg A. Grell; Dongsoo Kim; Barry E. Schwartz; Tatiana G. Smirnova; Tracy Lorraine Smith; Geoffrey S. Manikin

2004-02-01T23:59:59.000Z

151

Hourly Energy Emission Factors for Electricity Generation in...  

Open Energy Info (EERE)

Hourly Energy Emission Factors for Electricity Generation in the United States

Emissions from energy use in buildings are usually estimated on an annual...

152

The Temperature Sensitivity of the Residential Load and Commercial Building Load  

SciTech Connect

This paper presents a building modeling approach to quickly quantify climate change impacts on energy consumption, peak load, and load composition of residential and commercial buildings. This research focuses on addressing the impact of temperature changes on the building heating and cooling load in 10 major cities across the Western United States and Canada. A building simulation software are first used to quantify the hourly energy consumption of different building types by end-use and by vintage. Then, the temperature sensitivities are derived based on the climate data inputs.

Lu, Ning; Taylor, Zachary T.; Jiang, Wei; Correia, James; Leung, Lai R.; Wong, Pak C.

2009-07-26T23:59:59.000Z

153

Assessment of seismic resistance of a basilica-type church under earthquake loading: Modelling and analysis  

Science Conference Proceedings (OSTI)

In this paper a finite element methodology for the static and dynamic non-linear analysis of historical masonry structures is described and applied to a case study. A basilica-type masonry church is analysed in order to assess its structural behaviour ... Keywords: Earthquake loading, FE modeling seismic vulnerability, Historical masonry building, Non-linear analysis, Strengthening techniques

Michele Betti; Andrea Vignoli

2008-04-01T23:59:59.000Z

154

Wind Power Plants and System Operation in the Hourly Time Domain: Preprint  

DOE Green Energy (OSTI)

Because wind is an intermittent power source, the variability may have significant impacts on system operation. Part of the difficulty of analyzing the load following impact of wind is the inadequacy of most modeling frameworks to accurately treat wind plants and the difficulty of untangling causal impacts of wind plants from other dynamic phenomena. This paper presents a simple analysis of an hourly load-following requirement that can be performed without extensive computer modeling. The approach is therefore useful as a first step to quantifying these impacts when extensive modeling and data sets are not available. The variability that wind plants add to the electricity supply must be analyzed in the context of overall system variability. The approach used in this paper does just that. The results show that wind plants do have an impact on load following, but when calculated as a percentage of the installed wind plant capacity, this impact is not large. Another issue is the extent to which wind forecast errors add to imbalance. The relative statistical independence of wind forecast errors and load forecast errors can be used to help quantify the extent to which wind forecast errors impact overall system imbalances.

Milligan, M.

2003-05-01T23:59:59.000Z

155

Building Energy Software Tools Directory: HAP System Design Load  

NLE Websites -- All DOE Office Websites (Extended Search)

HAP System Design Load HAP System Design Load HAP System Design Load logo. Provides the load estimating and system design features found in its popular cousin � Carrier�s Hourly Analysis Program (HAP). By focusing on system design features, the HAP System Design Load program serves as a simpler, more efficient tool for those users only interested in system design; energy simulation features are omitted. Like the HAP program, HAP System Design Load provides the ease of use of a Windows-based graphical user interface and the computing power of modern 32-bit software. HAP System Design Load uses a system-based approach to HVAC load estimating. This approach tailors sizing procedures and results to the specific type of system being considered. A wide variety of equipment types

156

Propane Watch, historical - Energy Information Administration  

U.S. Energy Information Administration (EIA)

Historical. Propane stocks and prices available weekly during October through March and monthly during the rest of the year.

157

Battery loading device  

SciTech Connect

A battery loading device for loading a power source battery, built in small appliances having a battery loading chamber for selectively loading a number of cylindrical unit batteries or a one body type battery having the same voltage as a number of cylindrical unit batteries, whereby the one body type battery and the battery loading chamber are shaped similarly and asymmetrically in order to prevent the one body type battery from being inserted in the wrong direction.

Phara, T.; Suzuki, M.

1984-08-28T23:59:59.000Z

158

SPR - Historical Oil Sales and Exchanges | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

- Historical Oil Sales and Exchanges SPR - Historical Oil Sales and Exchanges SPR - Historical Oil Sales and Exchanges More Documents & Publications Before the Senate Energy and...

159

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network (OSTI)

composition: The total load profile obtained from  load individual load types if  load profiles of individual load composition validation: Load profiles generated by the load 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

160

Form EIA-930 HOURLY AND DAILY BALANCING AUTHORITY OPERATIONS REPORT  

U.S. Energy Information Administration (EIA) Indexed Site

930 930 HOURLY AND DAILY BALANCING AUTHORITY OPERATIONS REPORT INSTRUCTIONS Due Date: mm/dd/yyyy Approved: OMB No. 1905-0129 Approval Expires: 10/31/2016 Burden: 0.19 hours Page 1 Draft for Discussion only PURPOSE Form EIA-930 requires Internet posting of hourly balancing authority operating data. The posted data are used to monitor the current status and trends of the electric power industry, and to support enhancement of electric system operations. REQUIRED RESPONDENTS For the contiguous United States: all entities that are listed in NERC's Compliance Registry as a balancing authority must post balancing authority operating information required by this survey. Other than the Midwest ISO (MISO), registered balancing authorities that are parties

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

INCITE Program Doles Out Hours on Supercomputers | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

INCITE Program Doles Out Hours on Supercomputers INCITE Program Doles Out Hours on Supercomputers INCITE Program Doles Out Hours on Supercomputers November 5, 2012 - 1:30pm Addthis Mira, the 10-petaflop IBM Blue Gene/Q system at Argonne National Laboratory, is capable of carrying out 10 quadrillion calculations per second. Each year researchers apply to the INCITE program to get to use this machine's incredible computing power. | Photo courtesy of Argonne National Lab. Mira, the 10-petaflop IBM Blue Gene/Q system at Argonne National Laboratory, is capable of carrying out 10 quadrillion calculations per second. Each year researchers apply to the INCITE program to get to use this machine's incredible computing power. | Photo courtesy of Argonne National Lab. Charles Rousseaux Charles Rousseaux Senior Writer, Office of Science

162

Historic Building Renovations | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Historic Building Renovations Historic Building Renovations Historic Building Renovations October 16, 2013 - 4:52pm Addthis Renewable Energy Options for Historical Building Renovations Photovoltaics (PV) Solar Water Heating Geothermal Heat Pumps Biomass Heating When a Federal agency undertakes a renovation to an historic building, the renovation team must consider not only the uses and needs of the facility, but also a range of issues related to historic preservation. Integrating renewable energy such as solar and wind into an historic renovation has been accomplished successfully by agencies; the design and placement of any renewable energy system must be closely integrated with the overall design plans. Any renewable energy additions must maintain the integrity and defining characteristics of the building.

163

Historical Natural Gas Annual - 1930 Through 2000  

Gasoline and Diesel Fuel Update (EIA)

Historical Natural Gas Annual Historical Natural Gas Annual 1930 Through 2000 EIA Home > Natural Gas > Natural Gas Data Publications Historical Natural Gas Annual The Historical Natural Gas Annual contains historical information on supply and disposition of natural gas at the national, regional, and State level as well as prices at selected points in the flow of gas from the wellhead to the burner-tip. Data include production, transmission within the United States, imports and exports of natural gas, underground storage activities, and deliveries to consumers. The publication presents historical data at the national level for 1930-2000 and detailed annual historical information by State for 1967-2000. To read reports in PDF format download a free copy of Adobe Acrobat Reader.

164

Regional load-curve models. Volume 5. Data base. Final report  

SciTech Connect

In preparing to build the models detailed in the first four volumes of the EA-1672 reports, a substantial data gathering, clean-up, and organizing effort was conducted. This volume describes that process and documents the data banks sent to EPRI. Three types of data concepts were needed to explore hourly load forecasting: hourly load, hourly weather and related socioeconomic data concepts. These materials were gathered for the project. EPRI has 32 data tapes that include hourly load and weather data for 32 regions for the period 1962 to 1977. Two other data banks, EPRIDATAA and EPRIDATAM, contain annual and monthly data respectively, gathered for use in this project. Hourly load forecasts out to the year 2000 have also been received by EPRI. DRI's forecasts are contained in the data bank FORECASTBANK. QUERI's forecasts are also available. These data series may prove useful to other researchers exploring related topics.

Platt, H.D.

1984-04-01T23:59:59.000Z

165

Load sensing system  

DOE Patents (OSTI)

A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast

Sohns, Carl W. (Oak Ridge, TN); Nodine, Robert N. (Knoxville, TN); Wallace, Steven Allen (Knoxville, TN)

1999-01-01T23:59:59.000Z

166

Load Response Fundamentally Matches Power System Reliability Requirements  

Science Conference Proceedings (OSTI)

Responsive load is the most underutilized reliability resource available to the power system. Loads are frequently barred from providing the highest value and most critical reliability services; regulation and spinning reserve. Advances in communications and control technology now make it possible for some loads to provide both of these services. The limited storage incorporated in some loads better matches their response capabilities to the fast reliability-service markets than to the hourly energy markets. Responsive loads are frequently significantly faster and more accurate than generators, increasing power system reliability. Incorporating fast load response into microgrids further extends the reliability response capabilities that can be offered to the interconnected power system. The paper discusses the desired reliability responses, why this matches some loads' capabilities, what the advantages are for the power system, implications for communications and monitoring requirements, and how this resource can be exploited.

Kirby, Brendan J [ORNL

2007-01-01T23:59:59.000Z

167

Discharge circuits and loads  

SciTech Connect

This will be an overview in which some of the general properties of loads are examined: their interface with the energy storage and switching devices; general problems encountered with different types of loads; how load behavior and fault modes can impact on the design of a power conditioning system (PCS).

Sarjeant, W.J.

1980-10-15T23:59:59.000Z

168

Renewable Energies program (6 credit hour) Option A: 11  

E-Print Network (OSTI)

Renewable Energies program (6 credit hour) Option A: 11 Option B: The program is organized by t Spanish Institute and the Asso program on renewable energy will provide students with advanced knowledge. opportunities: option A- two renewable energies; option B include on-site visits to renewable energy generation

Simaan, Nabil

169

A Quality-Control Routine for Hourly Wind Observations  

Science Conference Proceedings (OSTI)

The quality of hourly wind speed and direction observations from 41 northeastern U.S. first-order weather stations is evaluated with regard to the recognition of individual observations that are either obviously in error or of suspect quality. An ...

Arthur T. DeGaetano

1997-04-01T23:59:59.000Z

170

Storing hydroelectricity to meet peak-hour demand  

Science Conference Proceedings (OSTI)

This paper reports on pumped storage plants which have become an effective way for some utility companies that derive power from hydroelectric facilities to economically store baseload energy during off-peak hours for use during peak hourly demands. According to the Electric Power Research Institute (EPRI) in Palo Alto, Calif., 36 of these plants provide approximately 20 gigawatts, or about 3 percent of U.S. generating capacity. During peak-demand periods, utilities are often stretched beyond their capacity to provide power and must therefore purchase it from neighboring utilities. Building new baseload power plants, typically nuclear or coal-fired facilities that run 24 hours per day seven days a week, is expensive, about $1500 per kilowatt, according to Robert Schainker, program manager for energy storage at the EPRI. Schainker the that building peaking plants at $400 per kilowatt, which run a few hours a day on gas or oil fuel, is less costly than building baseload plants. Operating them, however, is more expensive because peaking plants are less efficient that baseload plants.

Valenti, M.

1992-04-01T23:59:59.000Z

171

National Historic Preservation Act | Open Energy Information  

Open Energy Info (EERE)

Act Act Jump to: navigation, search Statute Name National Historic Preservation Act Year 1966 Url [[File:|160px|link=http://www.achp.gov/docs/nhpa%202008-final.pdf]] Description 16 USC 470a et seq (2006) and implementing regulations at 36 CFR 800 (2008) References Advisory Council on Historic Preservation[1] (pdf) National Historic Preservation Act[2] 16 USC 470a et seq (2006) and implementing regulations at 36 CFR 800 (2008) The goal of the National Historic Preservation Act (NHPA), which established the Advisory Council on Historic Preservation (ACHP) in 1966, is to have federal agencies act as responsible stewards of our nation's resources when their actions affect historic properties. The ACHP is the only entity with the legal responsibility to encourage federal agencies to

172

A Historic Commitment to Research and Education  

NLE Websites -- All DOE Office Websites (Extended Search)

A Historic Commitment to Research and Education WASHINGTON, DC - In a speech to the National Academy of Sciences, President Obama outlined a bold commitment to basic and applied...

173

Historical Procurement Information | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Note - historical means what the Department has bought in the past. Our procurement Forecast shows what we will buy in the future. Construction Forestry Goods Manufacturing...

174

Historically Underrepresented Communities | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Historically Underrepresented Communities Historically Underrepresented Communities Historically Underrepresented Communities The Department recognizes that embracing diversity in all aspects of our operations is crucial to achieving our mission. Diversity is more than simply numbers and statistics, it is a cross-cutting imperative of our people, programs, partners, and innovation at the Department. Everyone deserves equal participation and access to the energy programs of the Department, and, with the support of Secretary Moniz and President Obama, the Department's Office of Diversity and Inclusion seeks to ensure that underrepresented communities are always at the table. To this end, we seek to help historically underrepresented communities learn how to work with the Department, rectify environmental injustices,

175

Gasoline Prices at Historical Lows  

Gasoline and Diesel Fuel Update (EIA)

0 0 Notes: Before looking at El Paso gasoline prices, let’s take a minute to look at the U.S. average price for context. Gasoline prices this year, adjusted for inflation, are the lowest ever. Back in March, before prices began to rise ahead of the traditional high-demand season, the U.S. average retail price fell to $1.00 per gallon. Prices rose an average of 7.5 cents, less than the typical seasonal runup, to peak in early June. Since then, prices have fallen back to $1.013. Given recent declines in crude oil and wholesale gasoline prices, we expect retail prices to continue to ease over at least the next few weeks. Since their sharp runup during the energy crises of the 1970’s, gasoline prices have actually been non-inflationary. Adjusting the historical prices by the Consumer Price Index, we can see that today’s

176

Market Driven Distributed Energy Storage Requirements for Load Management Applications  

Science Conference Proceedings (OSTI)

Electric energy storage systems are an enabling technology that could help meet the needs of electric utility by managing peak energy demands, helping shift the peak loads to off peak hours and improving the load factor of the electric distribution system. Applications of distributed energy storage systems (DESS) could also provide power quality and reliability benefits to customers and to the electric system. EPRI collaborated with several investor owned utilities to conduct a study to understand the te...

2007-04-18T23:59:59.000Z

177

Load sensing system  

DOE Patents (OSTI)

A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast inventories of stored nuclear material can be continuously monitored and inventoried of minimal cost. 4 figs.

Sohns, C.W.; Nodine, R.N.; Wallace, S.A.

1999-05-04T23:59:59.000Z

178

Historical seismometry database project: A comprehensive relational database for historical seismic records  

Science Conference Proceedings (OSTI)

The recovery and preservation of the patrimony made of the instrumental registrations regarding the historical earthquakes is with no doubt a subject of great interest. This attention, besides being purely historical, must necessarily be also scientific. ... Keywords: Historical seismometry, MySQL, Oracle, Relational database project

Andrea Bono

2007-01-01T23:59:59.000Z

179

Observed Temperature Effects on Hourly Residential Electric Load Reduction in Response to an Experimental Critical Peak Pricing Tariff  

E-Print Network (OSTI)

by building type and climate zone with the intent ofWe roughly describe the climate zones as Coast, Foothills,group A. Stratum B. SPP climate zone - description 1- Coast

Herter, Karen B.; McAuliffe, Patrick K.; Rosenfeld, Arthur H.

2005-01-01T23:59:59.000Z

180

Observed Temperature Effects on Hourly Residential Electric Load Reduction in Response to an Experimental Critical Peak Pricing Tariff  

E-Print Network (OSTI)

means of decreasing residential energy consumption. Journalreductions gained through residential CPP rates, with or7. Hypothetical effects of residential CPP rates with and

Herter, Karen B.; McAuliffe, Patrick K.; Rosenfeld, Arthur H.

2005-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

After-hours power status of office equipment and energy use of miscellaneous plug-load equipment  

E-Print Network (OSTI)

ovens and computer projectors are categorized as ‘electronics’ although they might alternatively be categorized as ‘heating’

Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Margaret; Busch, John F.

2004-01-01T23:59:59.000Z

182

After-hours power status of office equipment and energy use of miscellaneous plug-load equipment  

E-Print Network (OSTI)

industrial refrigerator, S freezer incandescent tracklight, 50 lamps each phone/PBX centrex system coffee maker, residential model microwave oven

Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Margaret; Busch, John F.

2004-01-01T23:59:59.000Z

183

Historical Natural Gas Annual - 1930 Through 2000  

Gasoline and Diesel Fuel Update (EIA)

2000 2000 The Historical Natural Gas Annual contains historical information on supply and disposition of natural gas at the national, regional, and State level as well as prices at selected points in the flow of gas from the wellhead to the burner-tip. Data include production, transmission within the United States, imports and exports of natural gas, underground storage activities, and deliveries to consumers. The publication presents historical data at the national level for 1930-2000 and detailed annual historical information by State for 1967-2000. Entire . The entire report as a single file. PDF 1.5 MB Front Matter . Historical Natural Gas Annual Cover Page, Preface, Common Abbreviations Used, and Table of Contents PDF . . Tables . 1 Quantity and Average Price of Natural Gas Production in the United States, 1930-1998 PDF

184

Cultural (Historical) Resource Management, Environmental Protection  

NLE Websites -- All DOE Office Websites (Extended Search)

History Homepage History Homepage Accelerators & Detectors Cosmotron AGS Strong-focusing 80" Bubble Chamber The omega-minus 7' Bubble Chamber The charmed baryon NSLS RHIC Reactors Graphite Research Reactor High Flux Beam Reactor Medical Research Reactor Life Sciences Medical breakthroughs Biology research Plant Genetics Other BNL Nobel Prizes The First Video Game? BNL Physics Timeline Camp Upton Historic Images BNL Cultural (Historical) Resource Management Cultural (Historical) Resource Management at Brookhaven National Laboratory Photograph of the remains of WWI training trenches The Environmental Protection Division is responsible for ensuring compliance with historic preservation requirements. The BNL Cultural Resource Management Plan identifies and describes the management plans for of all of BNL's cultural resources. These resources include World War I trenches, Civilian Conservation Corps features, World War II buildings, and historic structures, programs and discoveries associated with high energy physics, research reactors, and other science conducted at the Laboratory.

185

ANN-Based Short-Term Load Forecasting in Electricity Markets  

E-Print Network (OSTI)

Abstract—This paper proposes an Artificial Neural Network (ANN)-based short-term load forecasting technique that considers electricity price as one of the main characteristics of the system load, demonstrating the importance of considering pricing when predicting loading in today’s electricity markets. Historical load data from the Ontario Hydro system as well as pricing information from the neighboring system are used for testing, showing the good performance of the proposed method. Keywords: Short-term load forecasting, electricity markets, spot prices, Artificial Neural Networks (ANN)

Hong Chen; Claudio A. Cañizares; Ajit Singh

2001-01-01T23:59:59.000Z

186

Structural load combinations  

SciTech Connect

This paper presents the latest results of the program entitled, ''Probability Based Load Combinations For Design of Category I Structures''. In FY 85, a probability-based reliability analysis method has been developed to evaluate safety of shear wall structures. The shear walls are analyzed using stick models with beam elements and may be subjected to dead load, live load and in-plane eqrthquake. Both shear and flexure limit states are defined analytically. The limit state probabilities can be evaluated on the basis of these limit states. Utilizing the reliability analysis method mentioned above, load combinations for the design of shear wall structures have been established. The proposed design criteria are in the load and resistance factor design (LRFD) format. In this study, the resistance factors for shear and flexure and load factors for dead and live loads are preassigned, while the load factor for SSE is determined for a specified target limit state probability of 1.0 x 10/sup -6/ or 1.0 x 10/sup -5/ during a lifetime of 40 years. 23 refs., 9 tabs.

Hwang, H.; Reich, M.; Ellingwood, B.; Shinozuka, M.

1985-01-01T23:59:59.000Z

187

Watershed Mercury Loading Framework  

Science Conference Proceedings (OSTI)

This report explains and illustrates a simplified stochastic framework, the Watershed Mercury Loading Framework, for organizing and framing site-specific knowledge and information on mercury loading to waterbodies. The framework permits explicit treatment of data uncertainties. This report will be useful to EPRI members, state and federal regulatory agencies, and watershed stakeholders concerned with mercury-related human and ecological health risk.

2003-05-23T23:59:59.000Z

188

Natural Gas Annual, 1999 (HISTORICAL)  

Gasoline and Diesel Fuel Update (EIA)

9 9 The Natural Gas Annual, 1999 provides information on the supply and disposition of natural gas in the United States. Production, transmission, storage, deliveries, and price data are published by State for 1999. Summary data are presented for each Census Division and State for 1995 to 1999. A section of historical data at the National level shows industry activities back to the 1930's. The data that appear in the tables of the Natural Gas Annual, 1999 are available as self-extracting executable files in ASCII TXT or CSV file formats. This volume emphasizes information for 1999, although some tables show a five-year history. Please read the file entitled README.V1 for a description and documentation of information included in this file. Also available are files containing the following data: Summary Statistics - Natural Gas in the United States, 1995-1999 (Table 1) ASCII TXT, and Natural Gas Supply and Disposition by State, 1999 (Table 2) ASCII TXT, are also available.

189

Load-management decision  

Science Conference Proceedings (OSTI)

Utilities require baseload, intermediate, and peaking plants to meet fluctuating customer demand. These can be supplemented with off-peak generation and storage and load management, which can take the form of direct utility control over interruptible and deferrable customers or customer incentives that require off-peak demand. Utilities should make a careful analysis of their load profile, their generation mix, their ability to shift loads, and customer attitudes before deciding on a load-management program that fits their individual needs. They should also be aware that load management is only a limited resource with a number of uncertainties. Research programs into customer relations, system reliability, communications devices, and special control switches and meters will help to relieve some of the uncertainties. (DCK)

Lihach, N.; Gupta, P.

1982-05-01T23:59:59.000Z

190

Implementing Solar PV Projects on Historic Buildings and in Historic Districts  

DOE Green Energy (OSTI)

Many municipalities, particularly in older communities of the United States, have a large amount of historic buildings and districts. In addition to preserving these historic assets, many municipalities have goals or legislative requirements to procure a certain amount of energy from renewable sources and to become more efficient in their energy use; often, these requirements do not exempt historic buildings. This paper details findings from a workshop held in Denver, Colorado, in June 2010 that brought together stakeholders from both the solar and historic preservation industries. Based on these findings, this paper identifies challenges and recommends solutions for developing solar photovoltaic (PV) projects on historic buildings and in historic districts in such a way as to not affect the characteristics that make a building eligible for historic status.

Kandt, A.; Hotchkiss, E.; Walker, A.; Buddenborg, J; Lindberg, J.

2011-09-01T23:59:59.000Z

191

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Cuba from NREL Cuba from NREL Dataset Summary Description (Abstract): Each data file is a set of hourly values of solar radiation and meteorological elements for a 1-year period. Solar radiation is modeled using the NREL METSTAT model, with surface observed cloud cover being the principal model input. Each container file contains up to 30 yearly files for one station, plus the Typical Meteorological Year (TMY) file for the selected station, plus documentation files and a TMY data reader file for use with Microsoft Excel. (Purpose): Simulations (Supplemental Information): The intended use of these data files is for computer simulations of solar energy conversion systems and building systems. The yearly data may be suitable for designing systems and their components to meet the worst-case conditions occurring at a location, if enough years of data are present. The TMY consists of months selected from individual years and concatenated to form a complete year.. Because of the selection criteria, these TMYs are not appropriate for simulations of wind energy conversion systems. A TMY provides a standard for hourly data for solar radiation and other meteorological elements that permit performance comparisons of system types and configurations for one or more locations. A TMY is not necessarily a good indicator of conditions over the next year, or even the next 5 years. Rather, it represents conditions judged to be typical over a long period of time, such as 30 years.

192

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Nepal from NREL Nepal from NREL Dataset Summary Description (Abstract): Each data file is a set of hourly values of solar radiation and meteorological elements for a 1-year period. Solar radiation is modeled using the NREL METSTAT model, with surface observed cloud cover being the principal model input. Each container file contains up to 30 yearly files for one station, plus the Typical Meteorological Year (TMY) file for the selected station, plus documentation files and a TMY data reader file for use with Microsoft Excel. (Purpose): Simulations (Supplemental Information): The intended use of these data files is for computer simulations of solar energy conversion systems and building systems. The yearly data may be suitable for designing systems and their components to meet the worst-case conditions occurring at a location, if enough years of data are present. The TMY consists of months selected from individual years and concatenated to form a complete year.. Because of the selection criteria, these TMYs are not appropriate for simulations of wind energy conversion systems. A TMY provides a standard for hourly data for solar radiation and other meteorological elements that permit performance comparisons of system types and configurations for one or more locations. A TMY is not necessarily a good indicator of conditions over the next year, or even the next 5 years. Rather, it represents conditions judged to be typical over a long period of time, such as 30 years.

193

Folding Proteins at 500 ns/hour with Work Queue  

E-Print Network (OSTI)

Abstract—Molecular modeling is a field that traditionally has large computational costs. Until recently, most simulation techniques relied on long trajectories, which inherently have poor scalability. A new class of methods is proposed that requires only a large number of short calculations, and for which minimal communication between computer nodes is required. We considered one of the more accurate variants called Accelerated Weighted Ensemble Dynamics (AWE) and for which distributed computing can be made efficient. We implemented AWE using the Work Queue framework for task management and applied it to an all atom protein model (Fip35 WW domain). We can run with excellent scalability by simultaneously utilizing heterogeneous resources from multiple computing platforms such as clouds (Amazon EC2, Microsoft Azure), dedicated clusters, grids, on multiple architectures (CPU/GPU, 32/64bit), and in a dynamic environment in which processes are regularly added or removed from the pool. This has allowed us to achieve an aggregate sampling rate of over 500 ns/hour. As a comparison, a single process typically achieves 0.1 ns/hour. I.

Badi Abdul-wahid; Li Yu; Dinesh Rajan

2012-01-01T23:59:59.000Z

194

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Kenya from NREL Kenya from NREL Dataset Summary Description (Abstract): Each data file is a set of hourly values of solar radiation and meteorological elements for a 1-year period. Solar radiation is modeled using the NREL METSTAT model, with surface observed cloud cover being the principal model input. Each container file contains up to 30 yearly files for one station, plus the Typical Meteorological Year (TMY) file for the selected station, plus documentation files and a TMY data reader file for use with Microsoft Excel. (Purpose): Simulations (Supplemental Information): The intended use of these data files is for computer simulations of solar energy conversion systems and building systems. The yearly data may be suitable for designing systems and their components to meet the worst-case conditions occurring at a location, if enough years of data are present. The TMY consists of months selected from individual years and concatenated to form a complete year.. Because of the selection criteria, these TMYs are not appropriate for simulations of wind energy conversion systems. A TMY provides a standard for hourly data for solar radiation and other meteorological elements that permit performance comparisons of system types and configurations for one or more locations. A TMY is not necessarily a good indicator of conditions over the next year, or even the next 5 years. Rather, it represents conditions judged to be typical over a long period of time, such as 30 years.

195

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

China from NREL China from NREL Dataset Summary Description (Abstract): Each data file is a set of hourly values of solar radiation and meteorological elements for a 1-year period. Solar radiation is modeled using the NREL METSTAT model, with surface observed cloud cover being the principal model input. Each container file contains up to 30 yearly files for one station, plus the Typical Meteorological Year (TMY) file for the selected station, plus documentation files and a TMY data reader file for use with Microsoft Excel. (Purpose): Simulations (Supplemental Information): The intended use of these data files is for computer simulations of solar energy conversion systems and building systems. The yearly data may be suitable for designing systems and their components to meet the worst-case conditions occurring at a location, if enough years of data are present. The TMY consists of months selected from individual years and concatenated to form a complete year. Because of the selection criteria, these TMYs are not appropriate for simulations of wind energy conversion systems. A TMY provides a standard for hourly data for solar radiation and other meteorological elements that permit performance comparisons of system types and configurations for one or more locations. A TMY is not necessarily a good indicator of conditions over the next year, or even the next 5 years. Rather, it represents conditions judged to be typical over a long period of time, such as 30 years.

196

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Bangladesh stations from NREL Bangladesh stations from NREL Dataset Summary Description (Abstract): Each data file is a set of hourly values of solar radiation and meteorological elements for a 1-year period. Solar radiation is modeled using the NREL METSTAT model, with surface observed cloud cover being the principal model input. Each container file contains up to 30 yearly files for one station, plus the Typical Meteorological Year (TMY) file for the selected station, plus documentation files and a TMY data reader file for use with Microsoft Excel. (Purpose): Simulations (Supplemental Information): The intended use of these data files is for computer simulations of solar energy conversion systems and building systems. The yearly data may be suitable for designing systems and their components to meet the worst-case conditions occurring at a location, if enough years of data are present. The TMY consists of months selected from individual years and concatenated to form a complete year.. Because of the selection criteria, these TMYs are not appropriate for simulations of wind energy conversion systems. A TMY provides a standard for hourly data for solar radiation and other meteorological elements that permit performance comparisons of system types and configurations for one or more locations. A TMY is not necessarily a good indicator of conditions over the next year, or even the next 5 years. Rather, it represents conditions judged to be typical over a long period of time, such as 30 years.

197

End-Use Load-Shape Estimation: Methods and Validation  

Science Conference Proceedings (OSTI)

In developing effective demand-side management plans and load forecasts, utilities need information on customer hourly load patterns over a range of end-uses. Such information may be obtained using the two methods described in this report for disaggregating whole-building load data. Both methods have been validated using end-use metered data. This report is available only to funders of Program 101A or 101.001. Funders may download this report at http://my.primen.com/Applications/DE/Community/index.asp .

1991-02-01T23:59:59.000Z

198

Climatic indicators for estimating residential heating and cooling loads  

Science Conference Proceedings (OSTI)

An extensive data base of residential energy use generated with the DOE-2.1A simulation code provides an opportunity for correlating building loads predicted by an hourly simulation model to commonly used climatic parameters such as heating and cooling degree-days, and to newer parameters such as insolation-days and latent enthalpy-days. The identification of reliable climatic parameters for estimating cooling loads and the incremental loads for individual building components, such as changing ceiling and wall R-values, infiltration rates or window areas is emphasized.

Huang, Y.J.; Ritschard, R.; Bull, J.; Chang, L.

1986-11-01T23:59:59.000Z

199

Regional load-curve models: scenario and forecast using the DRI model. Final report. [Forecasts of electric power loads in 32 US regions  

SciTech Connect

Regional load curve models were constructed for 32 regions that have been created by aggregating hourly load data from 146 electric utilities. These utilities supply approximately 95% of the electricity consumed in the continental US. The 32 models forecast electricity demands by hour, 8784 regional load forecasts per year. Because projections are made for each hour in the year, contemporaneous forecasts are available for peak demands, megawatt hour demands, load factors, load duration curves, and typical load shapes. The forecast scenario is described and documented in this volume and the forecast resulting from the use of this scenario is presented. The highlights of this forecast are two observations: (1) peak demands will once again become winter phenomena. By the year 2000, 18 of the 32 regions peak in a winter month as compared with the 8 winter peaking regions in 1977. In the heating season, the model is responsive to the number of heating degree-hours, the penetration rate of electric heating equipment, and the rate at which this space conditioning equipment is utilized, which itself is functionally dependent on the level of real electricity prices and real incomes. Thus, as the penetration rate of electric heating equipment increases, winter season demands grow more rapidly than demands in other seasons and peaks begin to appear in winter months; and (2) load factors begin to increase in the forecast, reversing the trend which began in the early 1960s. Nationally, load factors do not leap upwards, instead they increase gradually from .609 in 1977 to .629 in the year 2000. The improvement is more consequential in some regions, with load factors increasing, at times, by .10 or more. In some regions, load factors continue to decline.

Platt, H.D.

1981-08-01T23:59:59.000Z

200

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Ghana from NREL Ghana from NREL Dataset Summary Description (Abstract): Each data file is a set of hourly values of solar radiation and meteorological elements for a 1-year period. Solar radiation is modeled using the NREL METSTAT model, with surface observed cloud cover being the principal model input. Each container file contains up to 30 yearly files for one station, plus the Typical Meteorological Year (TMY) file for the selected station, plus documentation files and a TMY data reader file for use with Microsoft Excel. (Purpose): Simulations (Supplemental Information): The intended use of these data files is for computer simulations of solar energy conversion systems and building systems. The yearly data may be suitable for designing systems and their components to meet the worst-case conditions occurring at a

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Sri Lanka from NREL Sri Lanka from NREL Dataset Summary Description (Abstract): Each data file is a set of hourly values of solar radiation and meteorological elements for a 1-year period. Solar radiation is modeled using the NREL METSTAT model, with surface observed cloud cover being the principal model input. Each container file contains up to 30 yearly files for one station, plus the Typical Meteorological Year (TMY) file for the selected station, plus documentation files and a TMY data reader file for use with Microsoft Excel. (Purpose): Simulations (Supplemental Information): The intended use of these data files is for computer simulations of solar energy conversion systems and building systems. The yearly data may be suitable for designing systems and their components to meet the worst-case conditions occurring at a

202

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Honduras from SUNY Honduras from SUNY Dataset Summary Description (Abstract): Zip file contains year-site specific files including time series of global, direct and diffuse irradiance (Purpose): The time series are useful for performing site specific simulation of customized solar energy systems (Supplemental Information): Each file's name identifies year and location, by listing Country_City_latitude-longitude_year, e.g., EL_SALVADOR_San_Salvador_13.75-89.15_98.out is for the city of San Salvador, in El Salvador, latitude 13.75 degrees, longitude -89.15 degrees, year 1998. The content of each file includes A one line header, listing latitude, longitude and ground elevation in meters,Hourly records including, year, month, day, time (GMT), global irradiance, direct irradiance and

203

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Brazil from NREL Brazil from NREL Dataset Summary Description (Abstract): Each data file is a set of hourly values of solar radiation and meteorological elements for a 1-year period. Solar radiation is modeled using the NREL METSTAT model, with surface observed cloud cover being the principal model input. Each container file contains up to 30 yearly files for one station, plus the Typical Meteorological Year (TMY) file for the selected station, plus documentation files and a TMY data reader file for use with Microsoft Excel. (Purpose): Simulations (Supplemental Information): The intended use of these data files is for computer simulations of solar energy conversion systems and building systems. The yearly data may be suitable for designing systems and their components to meet the worst-case conditions occurring at a

204

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Nicaragua from SUNY Nicaragua from SUNY Dataset Summary Description (Abstract): Zip file contains year-site specific files including time series of global, direct and diffuse irradiance (Purpose): The time series are useful for performing site specific simulation of customized solar energy systems (Supplemental Information): Each file's name identifies year and location, by listing Country_City_latitude-longitude_year, e.g., EL_SALVADOR_San_Salvador_13.75-89.15_98.out is for the city of San Salvador, in El Salvador, latitude 13.75 degrees, longitude -89.15 degrees, year 1998. The content of each file includes A one line header, listing latitude, longitude and ground elevation in meters,Hourly records including, year, month, day, time (GMT), global irradiance, direct irradiance and

205

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Central America from NREL Central America from NREL Dataset Summary Description (Abstract): Each data file is a set of hourly values of solar radiation and meteorological elements for a 1-year period. Solar radiation is modeled using the NREL METSTAT model, with surface observed cloud cover being the principal model input. Each container file contains up to 30 yearly files for one station, plus the Typical Meteorological Year (TMY) file for the selected station, plus documentation files and a TMY data reader file for use with Microsoft Excel. (Purpose): Simulations (Supplemental Information): The intended use of these data files is for computer simulations of solar energy conversion systems and building systems. The yearly data may be suitable for designing systems and their components to meet the worst-case conditions occurring at a

206

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Guatemala from SUNY Guatemala from SUNY Dataset Summary Description (Abstract): Zip file contains year-site specific files including time series of global, direct and diffuse irradiance (Purpose): The time series are useful for performing site specific simulation of customized solar energy systems (Supplemental Information): Each file's name identifies year and location, by listing Country_City_latitude-longitude_year, e.g., EL_SALVADOR_San_Salvador_13.75-89.15_98.out is for the city of San Salvador, in El Salvador, latitude 13.75 degrees, longitude -89.15 degrees, year 1998. The content of each file includes A one line header, listing latitude, longitude and ground elevation in meters,Hourly records including, year, month, day, time (GMT), global irradiance, direct irradiance and

207

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Cuba sites from SUNY Cuba sites from SUNY Dataset Summary Description (Abstract): Zip file contains year-site specific files including time series of global, direct and diffuse irradiance (Purpose): The time series are useful for performing site specific simulation of customized solar energy systems (Supplemental Information): Each file's name identifies year and location, by listing Country_City_latitude-longitude_year, e.g., EL_SALVADOR_San_Salvador_13.75-89.15_98.out is for the city of San Salvador, in El Salvador, latitude 13.75 degrees, longitude -89.15 degrees, year 1998. The content of each file includes A one line header, listing latitude, longitude and ground elevation in meters,Hourly records including, year, month, day, time (GMT), global irradiance, direct irradiance and

208

What do hourly performance data on a building tell us  

DOE Green Energy (OSTI)

Hourly performance data on a building contain valuable information on the dynamics of the building and of the HVAC systems. Quantities such as the building loss coefficient, solar gains, and the net effect of thermal masses and their couplings are all contained in the data. The building element vector analysis (BEVA) method has been applied to a multizone residential passive solar building monitored under the SERI Class B program. Using short-term data (approximately one week), the building parameters were regressed. With these as inputs, the subsequent performance of the building was well predicted. Using performance data for the period February 3-9, 1982, the building vectors were obtained by regression. The resulting best fit for the zone temperature is given. These parameters were used to predict the temperature for the period February 10-14. The resulting values are also plotted along with the outdoor temperature, solar radiation on a south vertical surface, and auxiliary energy for these periods.

Subbarao, K.

1984-11-01T23:59:59.000Z

209

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

El Salvador sites from SUNY El Salvador sites from SUNY Dataset Summary Description (Abstract): Zip file contains year-site specific files including time series of global, direct and diffuse irradiance (Purpose): The time series are useful for performing site specific simulation of customized solar energy systems (Supplemental Information): Each file's name identifies year and location, by listing Country_City_latitude-longitude_year, e.g., EL_SALVADOR_San_Salvador_13.75-89.15_98.out is for the city of San Salvador, in El Salvador, latitude 13.75 degrees, longitude -89.15 degrees, year 1998. The content of each file includes A one line header, listing latitude, longitude and ground elevation in meters,Hourly records including, year, month, day, time (GMT), global irradiance, direct irradiance and

210

Solar: hourly solar (direct normal (DNI), global horizontal (GHI), and  

Open Energy Info (EERE)

Ethiopia from NREL Ethiopia from NREL Dataset Summary Description (Abstract): Each data file is a set of hourly values of solar radiation and meteorological elements for a 1-year period. Solar radiation is modeled using the NREL METSTAT model, with surface observed cloud cover being the principal model input. Each container file contains up to 30 yearly files for one station, plus the Typical Meteorological Year (TMY) file for the selected station, plus documentation files and a TMY data reader file for use with Microsoft Excel. (Purpose): Simulations (Supplemental Information): The intended use of these data files is for computer simulations of solar energy conversion systems and building systems. The yearly data may be suitable for designing systems and their components to meet the worst-case conditions occurring at a

211

322 IEEE TRANSACTIONS ON POWER SYSTEMS. VOL. 25. NO. I. FEBRUARY 2010 Short-Term Load Forecasting: Similar  

E-Print Network (OSTI)

for Short Term Electrical Load Forecasting," IEEE Trans. PWRS, vol. 11, no. 1, Feb. 1996, pp. 397-402. [4Short-Term Load Forecasting by Feed-Forward Neural Networks Saied S. Sharif1 , James H. Taylor2) is presented for the hourly load forecasting of the coming days. In this approach, 24 independent networks

Luh, Peter

212

HLW Glass Waste Loadings  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HLW HLW Glass Waste Loadings Ian L. Pegg Vitreous State Laboratory The Catholic University of America Washington, DC Overview Overview  Vitrification - general background  Joule heated ceramic melter (JHCM) technology  Factors affecting waste loadings  Waste loading requirements and projections  WTP DWPF  DWPF  Yucca Mountain License Application requirements on waste loading  Summary Vitrification  Immobilization of waste by conversion into a glass  Internationally accepted treatment for HLW  Why glass?  Amorphous material - able to incorporate a wide spectrum of elements over wide ranges of composition; resistant to radiation damage  Long-term durability - natural analogs Relatively simple process - amenable to nuclearization at large  Relatively simple process - amenable to nuclearization at large scale  There

213

OpenEI - load  

Open Energy Info (EERE)

are given by a location defined by the Typical Meteorological Year (TMY) for which the weather data was collected. Commercial load data is sorted by the (TMY) site as a...

214

building load data | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

215

electric load data | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

216

commercial load | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

217

residential load | OpenEI Community  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Load data Image source: NREL...

218

Regulating new construction in historic areas  

E-Print Network (OSTI)

This study is an examination of how the restrictiveness of different design regulations impacts the process of new construction in historic areas. The North End, South End, and Back Bay neighborhoods of Boston were identified ...

Sellers-Garcia, Oliver

2006-01-01T23:59:59.000Z

219

Hawaii Department of Land and Natural Resources Historic Preservation...  

Open Energy Info (EERE)

Historic Preservation Division Jump to: navigation, search Name Hawaii Department of Land and Natural Resources Historic Preservation Division Address Kakuhihewa Building 601...

220

Oregon State Historic Preservation Office | Open Energy Information  

Open Energy Info (EERE)

Office Jump to: navigation, search Logo: Oregon State Historic Preservation Office Name Oregon State Historic Preservation Office Address 725 Summer St NE, Ste C Place Salem,...

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

White House Initiative on Historically Black Colleges and Universities...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

White House Initiative on Historically Black Colleges and Universities White House Initiative on Historically Black Colleges and Universities How WHI-HBCU are ran White House...

222

Photovoltaic (PV) Pricing Trends: Historical, Recent, and Near...  

NLE Websites -- All DOE Office Websites (Extended Search)

Photovoltaic (PV) Pricing Trends: Historical, Recent, and Near-Term Projections Title Photovoltaic (PV) Pricing Trends: Historical, Recent, and Near-Term Projections Publication...

223

Soy Protein ProductsChapter 1 Historical Aspects  

Science Conference Proceedings (OSTI)

Soy Protein Products Chapter 1 Historical Aspects Health Nutrition Biochemistry eChapters Health - Nutrition - Biochemistry AOCS Press Downloadable pdf of Chapter 1 Historical Aspects from the book ...

224

5th Annual Historically Black Colleges and Universities (HBCU...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5th Annual Historically Black Colleges and Universities (HBCU) Career Development Marketplace 5th Annual Historically Black Colleges and Universities (HBCU) Career Development...

225

Savannah River National Laboratory Meets with Historically Black...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savannah River National Laboratory Meets with Historically Black Colleges and Universities Savannah River National Laboratory Meets with Historically Black Colleges and...

226

Students, Faculty from Historically Black Colleges and Universities...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Students, Faculty from Historically Black Colleges and Universities Share Research with EM Laboratory in Successful Exchange Students, Faculty from Historically Black Colleges and...

227

Office of Energy Efficiency and Renewable Energy (EERE) -Historically...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency and Renewable Energy (EERE) -Historically Black Colleges and Universities Office of Energy Efficiency and Renewable Energy (EERE) -Historically Black Colleges and...

228

Gallery of Historic Photos | Y-12 National Security Complex  

NLE Websites -- All DOE Office Websites (Extended Search)

Gallery of Historic Photos Gallery of Historic Photos Ed Westcott Manhattan Project official photographer. All photos are by Ed Westcott, the government's official photographer for...

229

Composite Load Model Evaluation  

Science Conference Proceedings (OSTI)

The WECC load modeling task force has dedicated its effort in the past few years to develop a composite load model that can represent behaviors of different end-user components. The modeling structure of the composite load model is recommended by the WECC load modeling task force. GE Energy has implemented this composite load model with a new function CMPLDW in its power system simulation software package, PSLF. For the last several years, Bonneville Power Administration (BPA) has taken the lead and collaborated with GE Energy to develop the new composite load model. Pacific Northwest National Laboratory (PNNL) and BPA joint force and conducted the evaluation of the CMPLDW and test its parameter settings to make sure that: • the model initializes properly, • all the parameter settings are functioning, and • the simulation results are as expected. The PNNL effort focused on testing the CMPLDW in a 4-bus system. An exhaustive testing on each parameter setting has been performed to guarantee each setting works. This report is a summary of the PNNL testing results and conclusions.

Lu, Ning; Qiao, Hong (Amy)

2007-09-30T23:59:59.000Z

230

Building Energy Software Tools Directory: TRACE Load 700  

NLE Websites -- All DOE Office Websites (Extended Search)

Load 700 Load 700 TRACE Load 700 logo. Use TRACE Load 700 software - the building and load design modules of TRACE 700, Trane Air Conditioning Economics - to evaluate the effect of building orientation, size, shape, and mass based on hourly weather data and the resulting heat-transfer characteristics of air and moisture. To assure calculation integrity, the program uses algorithms recommended by the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). Choose from eight different ASHRAE cooling and heating methodologies, including the Exact Transfer Function. The program encourages "what if" analyses, allowing the user to enter construction details in any order and then easily change the resulting building model as the design progresses. Multiple project views and "drag-and-drop"

231

Utah State Historic Preservation Office | Open Energy Information  

Open Energy Info (EERE)

Office Office Jump to: navigation, search Name Utah State Historic Preservation Offic Address 300 S. Rio Grande Street Place Salt Lake City, Utah Zip 84101 Website http://history.utah.gov/state_ Coordinates 40.7623958°, -111.9047846° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.7623958,"lon":-111.9047846,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

232

An energy performance index for historic buildings  

E-Print Network (OSTI)

This thesis reports studies conducted on historic buildings from the 1880 to 1900 era. These buildings were recently renovated and many more years of service are expected. Derivation of an energy demand prediction index was the primary study goal. Texas Historic Commission files were a primary data source to probe the second study goal; definition of data base needs for technical studies using state historic office files. A statistically valid prediction equation was produced which covers buildings between 10,000 and 30,000 square feet in floor area. Buildings from Austin and Galveston, Texas were used in the derivation; thus, these findings are limited to climates similar to those locations. The second goal was also achieved since the file data available were sufficient to support the study. The input data file design provides a proven example for development of a final data base specification. Field audits validated method accuracy and reinforced the starting hypothesis, reused historic buildings are examples of sustainability in action. The massive construction of these buildings furnished 30?% of building energy demand. Also infiltration was found to be a minor energy demand factor for these climates. This last finding supports preserving historic windows and doors rather than replacing them with very efficient but historically inaccurate models.

Campbell, Scott

1991-01-01T23:59:59.000Z

233

Distribution substation load impacts of residential air conditioner load control  

SciTech Connect

An ongoing experiment to monitor the substation level load impacts of end-use load control is described. An overview of the data acquisition system, experimental procedures and analysis techniques are provided. Results of the 1983 and 1984 experiments demonstrate the value of aggregate load impact monitoring as a means of verifying load research results, calculating the diversity of end-use loads, and predicting the impacts of load management on the transmission and distribution systems.

Heffner, G.C.; Kaufman, D.A.

1985-07-01T23:59:59.000Z

234

Use of Residential Smart Appliances for Peak-Load Shifting and Spinning Reserves Cost/Benefit Analysis  

Science Conference Proceedings (OSTI)

In this report, we present the results of an analytical cost/benefit study of residential smart appliances from a utility/grid perspective in support of a joint stakeholder petition to the ENERGY STAR program within the Environmental Protection Agency (EPA) and Department of Energy (DOE). The goal of the petition is in part to provide appliance manufacturers incentives to hasten the production of smart appliances. The underlying hypothesis is that smart appliances can play a critical role in addressing some of the societal challenges, such as anthropogenic global warming, associated with increased electricity demand, and facilitate increased penetration of renewable sources of power. The appliances we consider include refrigerator/freezers, clothes washers, clothes dryers, room air-conditioners, and dishwashers. The petition requests the recognition that providing an appliance with smart grid capability, i.e., products that meet the definition of a smart appliance, is at least equivalent to a corresponding five percent in operational machine efficiencies. It is then expected that given sufficient incentives and value propositions, and suitable automation capabilities built into smart appliances, residential consumers will be adopting these smart appliances and will be willing participants in addressing the aforementioned societal challenges by more effectively managing their home electricity consumption. The analytical model we utilize in our cost/benefit analysis consists of a set of user-definable assumptions such as the definition of on-peak (hours of day, days of week, months of year), the expected percentage of normal consumer electricity consumption (also referred to as appliance loads) that can shifted from peak hours to off-peak hours, the average power rating of each appliance, etc. Based on these assumptions, we then formulate what the wholesale grid operating-cost savings, or benefits, would be if the smart capabilities of appliances were invoked, and some percentage of appliance loads were shifted away from peak hours to run during off-peak hours, and appliance loads served power-system balancing needs such as spinning reserves that would otherwise have to be provided by generators. The rationale is that appliance loads can be curtailed for about ten minutes or less in response to a grid contingency without any diminution in the quality of service to the consumer. We then estimate the wholesale grid operating-cost savings based on historical wholesale-market clearing prices (location marginal and spinning reserve) from major wholesale power markets in the United States. The savings derived from the smart grid capabilities of an appliance are then compared to the savings derived from a five percent increase in traditional operational machine efficiencies, referred to as cost in this report, to determine whether the savings in grid operating costs (benefits) are at least as high as or higher than the operational machine efficiency credit (cost).

Sastry, Chellury; Pratt, Robert G.; Srivastava, Viraj; Li, Shun

2010-12-01T23:59:59.000Z

235

Load Monitoring CEC/LMTF Load Research Program  

SciTech Connect

This white paper addresses the needs, options, current practices of load monitoring. Recommendations on load monitoring applications and future directions are also presented.

Huang, Zhenyu; Lesieutre, B.; Yang, Steve; Ellis, A.; Meklin, A.; Wong, B.; Gaikwad, A.; Brooks, D.; Hammerstrom, Donald J.; Phillips, John; Kosterev, Dmitry; Hoffman, M.; Ciniglio, O.; Hartwell, R.; Pourbeik, P.; Maitra, A.; Lu, Ning

2007-11-30T23:59:59.000Z

236

Mass-Loaded Flows  

E-Print Network (OSTI)

A key process within astronomy is the exchange of mass, momentum, and energy between diffuse plasmas in many types of astronomical sources (including planetary nebulae, wind-blown bubbles, supernova remnants, starburst superwinds, and the intracluster medium) and dense, embedded clouds or clumps. This transfer affects the large scale flows of the diffuse plasmas as well as the evolution of the clumps. I review our current understanding of mass-injection processes, and examine intermediate-scale structure and the global effect of mass-loading on a flow. I then discuss mass-loading in a variety of diffuse sources.

J. M. Pittard

2006-07-13T23:59:59.000Z

237

Implementing Solar Photovoltaic Projects on Historic Buildings and in Historic Districts  

SciTech Connect

Despite a global recession, the number of photovoltaic (PV) installations in the United States grew 30% from 2008 to 2009. A number of trends point toward continued growth of new PV installations. The efficiency of solar panels is increasing, while installation costs are going down. At the same time, federal, state, and local regulations are requiring that greater amounts of energy must come from renewable sources. Incentives for solar power technology implementation are being created and regulatory barriers removed. Corporations and governments are focusing on solar power to demonstrate leadership in environmental sustainability and resource conservation. Architects and builders are including PV arrays as a way to meet green building standards and property owners are seeking PV as a way to reduce their utility bills, as well as their carbon footprints. This publication focuses on the implementation of PV systems on historic properties. Many private property owners, as well as local, state, and national government entities, are seeking guidance on how best to integrate solar PV installations on historic buildings. Historic preservationists maintain that preserving, reusing, and maintaining historic structures is a key sustainable design strategy while also recognizing the importance of accommodating renewable energy technologies where they are appropriate. In some cases, however, conflicts have arisen over the installation of PV panels on historic properties. Addressing these conflicts and providing guidance regarding solutions and best practices is an important step toward resolving or eliminating barriers. Historic properties and districts in the United States provide tangible connections to the nation's past. Thousands of buildings, sites, districts, structures, and objects have been recognized for their historic and architectural significance. Local, state, and national designations of historic properties provide recognition, protection, and incentives that help to preserve those properties for future generations. At the national level, the National Register of Historic Places includes more than 86,000 listings, which encompass a total of more than 1.6 million historic resources. State registers of historic places also provide recognition and protection for historic sites and districts. Locally, more than 2,400 communities have established historic preservation ordinances. Typically implemented through zoning overlays, these local land use regulations manage changes to hundreds of thousands of historic properties. Over a period of 2 years (2007 and 2008) the U.S. Department of Energy (DOE) designated 25 major U.S. cities as Solar America Cities. DOE provided financial and technical assistance to help the cities develop comprehensive approaches to accelerate the adoption of solar energy technologies. The Solar America Cities partnerships represent the foundation of DOE's larger Solar America Communities program. As a part of this program, DOE identified the implementation of solar projects on historic properties and in historic districts as one area to address. A workshop titled 'Implementing Solar Projects on Historic Buildings and in Historic Districts' was held in Denver, Colorado, in June of 2010. Participants included representatives from the solar industry as well as historic preservationists from nonprofit organizations and government agencies at the local, state, and national levels. The workshop provided an opportunity to gain a common understanding of solar technologies and historic preservation procedures and priorities. The workshop participants also discussed some of the challenges involved in locating PV systems on historic properties and identified potential solutions. This publication is based on the discussions that occurred at this workshop and the recommendations that were developed by participants. Ideas expressed by participants in the workshop, and included in this document, do not necessarily reflect the opinion of any government council, agency, or entity.

Kandt, A.; Hotchkiss, E.; Walker, A.

2011-01-01T23:59:59.000Z

238

Cooling load estimation methods  

DOE Green Energy (OSTI)

Ongoing research on quantifying the cooling loads in residential buildings, particularly buildings with passive solar heating systems, is described. Correlations are described that permit auxiliary cooling estimates from monthly average insolation and weather data. The objective of the research is to develop a simple analysis method, useful early in design, to estimate the annual cooling energy required of a given building.

McFarland, R.D.

1984-01-01T23:59:59.000Z

239

LOADING AND UNLOADING DEVICE  

DOE Patents (OSTI)

A device for loading and unloading fuel rods into and from a reactor tank through an access hole includes parallel links carrying a gripper. These links enable the gripper to go through the access hole and then to be moved laterally from the axis of the access hole to the various locations of the fuel rods in the reactor tank.

Treshow, M.

1960-08-16T23:59:59.000Z

240

Multidimensional spectral load balancing  

DOE Patents (OSTI)

A method of and apparatus for graph partitioning involving the use of a plurality of eigenvectors of the Laplacian matrix of the graph of the problem for which load balancing is desired. The invention is particularly useful for optimizing parallel computer processing of a problem and for minimizing total pathway lengths of integrated circuits in the design stage.

Hendrickson, Bruce A. (Albuquerque, NM); Leland, Robert W. (Albuquerque, NM)

1996-12-24T23:59:59.000Z

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Buildings Stock Load Control  

E-Print Network (OSTI)

Researchers and practitioners have proposed a variety of solutions to reduce electricity consumption and curtail peak demand. This research focuses on electricity demand control by applying some strategies in existing building to reduce it during the extreme climate period. The first part of this paper presents the objectives of the study: ? to restrict the startup polluting manufacturing units (power station), ? to limit the environmental impacts (greenhouse emission), ? to reduce the transport and distribution electricity infrastructures The second part presents the approach used to rise the objectives : ? To aggregat the individual loads and to analyze the impact of different strategies from load shedding to reduce peak power demand by: ? Developing models of tertiary buildings stocks (Schools, offices, Shops, hotels); ? Making simulations for different load shedding strategies to calculate potential peak power saving. The third part is dedicated to the description of the developed models: An assembly of the various blocks of the library of simbad and simulink permit to model building. Finally the last part prensents the study results: Graphs and tables to see the load shedding strategies impacts.

Joutey, H. A.; Vaezi-Nejad, H.; Clemoncon, B.; Rosenstein, F.

2006-01-01T23:59:59.000Z

242

OpenEI Community - load data  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

243

OpenEI Community - electric load data  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

244

OpenEI Community - building load  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

245

OpenEI Community - residential load  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

246

OpenEI Community - commercial load  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

247

OpenEI Community - building load data  

Open Energy Info (EERE)

building load data commercial load data dataset datasets electric load data load data load profile OpenEI residential load TMY3 United States Utility Rate OpenEI Community...

248

Independent review of estimated load reductions for PJM's small customer load response pilot project  

SciTech Connect

This study describes the results of a low-cost approach used to measure reported load reductions from a residential electric water heater (EWH) load control program operated as part of PJM Interconnection's Demand Response small customer pilot program. Lawrence Berkeley National Laboratory (LBNL) conducted this independent review of the engineering estimates for EWH load control reported by a Curtailment Service Provider (CSP) at PJM's request. LBNL employed low-cost measurement and verification (M&V) approaches that utilized existing interval metering equipment to monitor results for a series of load control tests. The CSP collected hourly load data for two substations and several hundred households over a six-week period in October and November 2003. During this time period, the CSP operated its electric water heater load control program during pre-specified test periods in the morning, afternoon and early evening. LBNL then analyzed substation and premise-level data from these tests in order to verify the diversified demand reductions claimed by the CSP for customers participating in the EWH load control program. We found that the observed load reductions for the premise-level data aggregated over all households in the two participating electric cooperatives were, respectively, 40 percent-60 percent less and 3 percent less-10 percent higher than the estimated diversified demand reduction values assumed by the CSP, depending on whether observed or normalized results are considered. We also analyzed sub-station level data and found that the observed load reductions during the test periods were significantly lower than expected, although confounding influences and operational problems signifiogram during pre-specified test periods in the morning, afternoon and early evening. LBNL then analyzed substation and premise-level data from these tests in order to verify the diversified demand reductions claimed by the CSP for customers participating in the EWH load control program. We found that the observed load reductions for the premise-level data aggregated over all households in the two participating electric cooperatives were, respectively, 40 percent-60 percent less and 3 percent less-10 percent higher than the estimated diversified demand reduction values assumed by the CSP, depending on whether observed or normalized results are considered. We also analyzed sub-station level data and found that the observed load reductions during the test periods were significantly lower than expected, although confounding influences and operational problems significantly limit our ability to differentiate between control-related and non-control related differences in substation-level load shape data. The usefulness and accuracy of the results were hampered by operational problems encountered during the measurement period as well as in sufficient number of load research grade interval meters at one cooperative. Given the larger sample size at one electric cooperative and more statistically-robust results, there is some basis to suggest that the Adjusted Diversified Demand Factor (ADDF) values used by the CSP somewhat over-state the actual load reductions. Given the results and limitations of the M&V approach as implemented, we suggest several options for PJM to consider: (1) require load aggregators participating in ISODR programs to utilize formal PURPA-compliant load research samples in their M&V plans, and (2) continue developing lower cost M&V approaches for mass market load control programs that incorporate suggested improvements described in this study.

Heffner, G.; Moezzi, M.; Goldman, C.

2004-06-01T23:59:59.000Z

249

Historical Media | Y-12 National Security Complex  

NLE Websites -- All DOE Office Websites (Extended Search)

Historical Media Historical Media Historical Media Image of Y-12 Bulletin dated August 16, 1949 The Y-12 Bulletin was published weekly between May 1947 and sometime in the 1980s. Select a year and a month at right and then click "Retrieve" to bring back links to Adobe PDF files of bulletins printed during that time. Image of T.E.C. Bulletin dated April 1, 1946 T.E.C. Bulletin "A newspaper for the men and women of the Clinton Engineer Works-Tennessee Eastman Corporation" (PDF). Dated Monday, April 1, 1946. (Size: 3 MB) Image of John Googin Employees' Guidebook "Things you will want to know about your job at Clinton Engineer Works, Tennessee Eastman Company" (PDF). Printed about 1944. (Size: 4.8 MB) 1947 1948 1949 1950 1951 1952 1953 1954 1955 1956 1957 1958 1959 1960 1961

250

Historical Natural Gas Annual 1930 through 1997  

Gasoline and Diesel Fuel Update (EIA)

7 7 October 1998 Energy Information Administration Office of Oil and Gas U.S. Department of Energy Washington, DC 20585 This report was prepared by the Energy Information Administration, the independent statistical and analytical agency within the Department of Energy. The information contained herein should not be construed as advocating or reflecting any policy of the Department of Energy or any other organization. DOE/EIA-E-0110(97) Distribution Category/UC-960 ii Energy Information Administration / Historical Natural Gas Annual 1930 Through 1997 Contacts The Historical Natural Gas Annual is prepared by the En- ergy Information Administration, Office of Oil and Gas, Reserves and Natural Gas Division, under the direction of Joan E. Heinkel. General questions and comments concerning the contents of the Historical Natural Gas Annual may be obtained from Ann M. Ducca (202/586-6137)

251

Estimating Hourly All-Sky Solar Irradiation Components from Meteorological Data  

Science Conference Proceedings (OSTI)

A new method to calculate hourly direct beam and diffuse irradiation on a horizontal surface using 3-h standard meteorological data is described. Comparisons of computed and observed irradiations are made with hourly data obtained in Carpentras ...

F. Kermel

1988-02-01T23:59:59.000Z

252

NOAA Awarded 2.6 Million Processor Hours at NERSC to Run Climate...  

NLE Websites -- All DOE Office Websites (Extended Search)

NOAA Awarded 2.6 Million Processor Hours at NERSC to Run Climate Change Models NOAA Awarded 2.6 Million Processor Hours at NERSC to Run Climate Change Models September 11, 2008...

253

Seasonal Variations in the Diurnal Characteristics of Heavy Hourly precipitation across the United States  

Science Conference Proceedings (OSTI)

Hourly precipitation data from 1967 to 1983 for the coterminous, United States were harmonically analyzed in order to document the diurnal variability of several categories of heavy hourly precipitation during winter, spring, summer, and autumn. ...

Julie A. Winkler; Brent R. Skeeter; Paul D. Yamamoto

1988-08-01T23:59:59.000Z

254

Comparison of Historical Satellite-Based Estimates of Solar Radiation Resources with Recent Rotating Shadowband Radiometer Measurements: Preprint  

DOE Green Energy (OSTI)

The availability of rotating shadow band radiometer measurement data at several new stations provides an opportunity to compare historical satellite-based estimates of solar resources with measurements. We compare mean monthly daily total (MMDT) solar radiation data from eight years of NSRDB and 22 years of NASA hourly global horizontal and direct beam solar estimates with measured data from three stations, collected after the end of the available resource estimates.

Myers, D. R.

2009-03-01T23:59:59.000Z

255

Load Capacity of Bodies  

E-Print Network (OSTI)

For the stress analysis in a plastic body $\\Omega$, we prove that there exists a maximal positive number $C$, the \\emph{load capacity ratio,} such that the body will not collapse under any external traction field $t$ bounded by $Y_{0}C$, where $Y_0$ is the elastic limit. The load capacity ratio depends only on the geometry of the body and is given by $$ \\frac{1}{C}=\\sup_{w\\in LD(\\Omega)_D} \\frac{\\int_{\\partial\\Omega}|w|dA} {\\int_{\\Omega}|\\epsilon(w)|dV}=\\left\\|\\gamma_D\\right\\|. $$ Here, $LD(\\Omega)_D$ is the space of isochoric vector fields $w$ for which the corresponding stretchings $\\epsilon(w)$ are assumed to be integrable and $\\gamma_D$ is the trace mapping assigning the boundary value $\\gamma_D(w)$ to any $w\\in LD(\\Omega)_D$.

Reuven Segev

2005-11-01T23:59:59.000Z

256

Load responsive hydrodynamic bearing  

Science Conference Proceedings (OSTI)

A load responsive hydrodynamic bearing is provided in the form of a thrust bearing or journal bearing for supporting, guiding and lubricating a relatively rotatable member to minimize wear thereof responsive to relative rotation under severe load. In the space between spaced relatively rotatable members and in the presence of a liquid or grease lubricant, one or more continuous ring shaped integral generally circular bearing bodies each define at least one dynamic surface and a plurality of support regions. Each of the support regions defines a static surface which is oriented in generally opposed relation with the dynamic surface for contact with one of the relatively rotatable members. A plurality of flexing regions are defined by the generally circular body of the bearing and are integral with and located between adjacent support regions. Each of the flexing regions has a first beam-like element being connected by an integral flexible hinge with one of the support regions and a second beam-like element having an integral flexible hinge connection with an adjacent support region. A least one local weakening geometry of the flexing region is located intermediate the first and second beam-like elements. In response to application of load from one of the relatively rotatable elements to the bearing, the beam-like elements and the local weakening geometry become flexed, causing the dynamic surface to deform and establish a hydrodynamic geometry for wedging lubricant into the dynamic interface.

Kalsi, Manmohan S. (Houston, TX); Somogyi, Dezso (Sugar Land, TX); Dietle, Lannie L. (Stafford, TX)

2002-01-01T23:59:59.000Z

257

Visualizing Plant Community Change Using Historical Records  

Science Conference Proceedings (OSTI)

Ecological data from land surveys from 1811 for the 100,000-acre Connecticut Tract in western New York were transcribed and then analyzed using ArcGIS and IDRISI GIS software. The surveys contained both witness tree data and line descriptions, which ... Keywords: Ecological Data, Geographical Information Systems, Historical Ecology, Land Use, Presettlement Surveys

Evelyn Brister; Elizabeth Hane; Karl Korfmacher

2011-10-01T23:59:59.000Z

258

Measured electric hot water standby and demand loads from Pacific Northwest homes. End-Use Load and Consumer Assessment Program  

SciTech Connect

The Bonneville Power Administration began the End-Use Load and Consumer Assessment Program (ELCAP) in 1983 to obtain metered hourly end-use consumption data for a large sample of new and existing residential and commercial buildings in the Pacific Northwest. Loads and load shapes from the first 3 years of data fro each of several ELCAP residential studies representing various segments of the housing population have been summarized by Pratt et al. The analysis reported here uses the ELCAP data to investigate in much greater detail the relationship of key occupant and tank characteristics to the consumption of electricity for water heating. The hourly data collected provides opportunities to understand electricity consumption for heating water and to examine assumptions about water heating that are critical to load forecasting and conservation resource assessments. Specific objectives of this analysis are to: (A) determine the current baseline for standby heat losses by determining the standby heat loss of each hot water tank in the sample, (B) examine key assumptions affecting standby heat losses such as hot water temperatures and tank sizes and locations, (C) estimate, where possible, impacts on standby heat losses by conservation measures such as insulating tank wraps, pipe wraps, anticonvection valves or traps, and insulating bottom boards, (D) estimate the EF-factors used by the federal efficiency standards and the nominal R-values of the tanks in the sample, (E) develop estimates of demand for hot water for each home in the sample by subtracting the standby load from the total hot water load, (F) examine the relationship between the ages and number of occupants and the hot water demand, (G) place the standby and demand components of water heating electricity consumption in perspective with the total hot water load and load shape.

Pratt, R.G.; Ross, B.A.

1991-11-01T23:59:59.000Z

259

Human-centered design meets cognitive load theory: designing interfaces that help people think  

Science Conference Proceedings (OSTI)

Historically, the development of computer systems has been primarily a technology-driven phenomenon, with technologists believing that "users can adapt" to whatever they build. Human-centered design advocates that a more promising and enduring ... Keywords: cognitive load, educational interfaces, human-centered design, mobile interfaces, multimodal interfaces, pen-based interfaces, performance metrics, robustness, spoken language interfaces, tangible interfaces, usability

Sharon Oviatt

2006-10-01T23:59:59.000Z

260

Question of the Week: How Are You Observing Earth Hour? | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Are You Observing Earth Hour? Are You Observing Earth Hour? Question of the Week: How Are You Observing Earth Hour? March 26, 2009 - 12:16pm Addthis This Saturday, March 28th, people around the world will observe Earth Hour at 8:30 p.m. local time-whatever the local time zone happens to be-by switching off their lights for one hour. While many people are taking part by simply shutting off their lights and lighting some candles, some communities are hosting gatherings or events around Earth Hour. How are you observing Earth Hour? Each Thursday, you have the chance to share your thoughts on a topic related to energy efficiency or renewable energy for consumers. Please e-mail your responses to the Energy Saver team at consumer.webmaster@nrel.gov. Addthis Related Articles Question of the Week: How Will You Save Energy this Spring?

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Variable loading roller  

DOE Patents (OSTI)

An automatic loading roller for transmitting torque in traction drive devices in manipulator arm joints includes a two-part camming device having a first cam portion rotatable in place on a shaft by an input torque and a second cam portion coaxially rotatable and translatable having a rotating drive surface thereon for engaging the driven surface of an output roller with a resultant force proportional to the torque transmitted. Complementary helical grooves in the respective cam portions interconnected through ball bearings interacting with those grooves effect the rotation and translation of the second cam portion in response to rotation of the first. 14 figs.

Williams, D.M.

1988-01-21T23:59:59.000Z

262

Vehicle Technologies Office: Fact #741: August 20, 2012 Historical...  

NLE Websites -- All DOE Office Websites (Extended Search)

1: August 20, 2012 Historical Gasoline Prices, 1929-2011 to someone by E-mail Share Vehicle Technologies Office: Fact 741: August 20, 2012 Historical Gasoline Prices, 1929-2011 on...

263

Vehicle Technologies Office: Fact #364: March 21, 2005 Historical...  

NLE Websites -- All DOE Office Websites (Extended Search)

4: March 21, 2005 Historical Gas Prices, 1919-2004 to someone by E-mail Share Vehicle Technologies Office: Fact 364: March 21, 2005 Historical Gas Prices, 1919-2004 on Facebook...

264

A Homogenized Historical Temperature Extreme Dataset for the United States  

Science Conference Proceedings (OSTI)

A subset of stations from the daily U.S. Historical Climatology Network (HCN) is used as a basis for a historical database of temperature extreme occurrence in the United States. The dataset focuses on daily temperature occurrences that exceed (...

Arthur T. DeGaetano; Robert J. Allen; Kevin P. Gallo

2002-09-01T23:59:59.000Z

265

A Statistical Approach to Historical Records of Flood and Drought  

Science Conference Proceedings (OSTI)

Statistical methods of dichotomous variables are suggested in order to analyze the historical climatic records in ancient writings. From historical descriptive records of floods and droughts, we calculate the variability, persistence and ...

C. S. Yao

1982-04-01T23:59:59.000Z

266

Vehicle Technologies Office: Fact #281: August 18, 2003 Historical...  

NLE Websites -- All DOE Office Websites (Extended Search)

1: August 18, 2003 Historical Light Vehicle Market Share to someone by E-mail Share Vehicle Technologies Office: Fact 281: August 18, 2003 Historical Light Vehicle Market Share on...

267

Emergency Response Transport Forecasting Using Historical Wind Field Pattern Matching  

Science Conference Proceedings (OSTI)

Historical pattern matching, or analog forecasting, is used to generate short-term mesoscale transport forecasts for emergency response at the Idaho National Engineering and Environmental Laboratory. A simple historical pattern-matching algorithm ...

Roger G. Carter; Robert E. Keislar

2000-03-01T23:59:59.000Z

268

Plug-In Electric Vehicle Charging Load Profile Forecasts for the Salt River Project Service Area  

Science Conference Proceedings (OSTI)

As plug-in electric vehicles (PEVs) enter the marketplace, it is important to understand the impacts of the potentially significant new load caused by PEV charging. Time-of-use (TOU) electricity pricing will help shift PEV charging loads to off-peak hours, mitigating the potential problem of raising the system peak load. However, there is a potential for a secondary peak to develop if the TOU plan causes a large PEV load to appear on the grid at a specific time in the evening. So-called smart chargingbid...

2011-06-30T23:59:59.000Z

269

Residential Transportation Historical Publications reports, data and  

U.S. Energy Information Administration (EIA) Indexed Site

Historical Publications Historical Publications Residential Transportation reports, data tables and transportation questionnaires Released: May 2008 The Energy Information Administration conducts several core consumption surveys. Among them was the Residential Transportation Energy Consumption Survey (RTECS). RTECS was designed by EIA to provide information on how energy is used by households for personal vehicles. It was an integral part of a series of surveys (i.e., core consumption surveys) designed by EIA to collect data on energy used by end-use economic sectors. The RTECS collected data on the number and type of vehicles used by the household. For each vehicle, data were collected on the number of miles traveled (commonly called VMT) for the year, the number of gallons of fuel consumed, the type of fuel used, the priced paid for fuel, and the number of miles per gallon. Additional electronic releases are available on the Transportation homepage.

270

Fermilab | Science at Fermilab | Historic Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Historic Results Historic Results Experimental physicists at Fermilab are constantly at work systematically building our understanding of the laws of nature. The following are some of the hallmark discoveries they have made at the three frontiers of research in particle physics. Energy Frontier Art work - Top Quark Headlines Top Quark headlines Discovery of the Top Quark Physicists observed the first proton-antiproton collisions produced by the Tevatron on Oct. 13, 1985. Researchers at the CDF experiment and at DZero, which began operating later in 1992, used the Tevatron to study matter at ever smaller scales. On March 2, 1995, physicists at CDF and DZero announced the discovery of the top quark. Researchers in both collaborations had statistically proven observation of the top quark in collisions at their detectors.

271

Utah Percent of Historical Gas Wells by Production Rate Bracket  

U.S. Energy Information Administration (EIA)

Utah Percent of Historical Gas Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

272

West Virginia Percent of Historical Gas Wells by Production Rate ...  

U.S. Energy Information Administration (EIA)

West Virginia Percent of Historical Gas Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

273

Kansas Percent of Historical Oil Wells by Production Rate Bracket  

U.S. Energy Information Administration (EIA)

Kansas Percent of Historical Oil Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

274

Kentucky Percent of Historical Oil Wells by Production Rate Bracket  

U.S. Energy Information Administration (EIA)

Kentucky Percent of Historical Oil Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

275

Mississippi Percent of Historical Gas Wells by Production Rate Bracket  

U.S. Energy Information Administration (EIA)

Mississippi Percent of Historical Gas Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

276

West Virginia Percent of Historical Oil Wells by Production Rate ...  

U.S. Energy Information Administration (EIA)

West Virginia Percent of Historical Oil Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

277

Federal Gulf Percent of Historical Gas Wells by Production Rate ...  

U.S. Energy Information Administration (EIA)

Federal Gulf Percent of Historical Gas Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

278

Alabama Percent of Historical Gas Wells by Production Rate Bracket  

U.S. Energy Information Administration (EIA)

Alabama Percent of Historical Gas Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

279

North Dakota Percent of Historical Gas Wells by Production Rate ...  

U.S. Energy Information Administration (EIA)

North Dakota Percent of Historical Gas Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

280

Pennsylvania Percent of Historical Gas Wells by Production Rate ...  

U.S. Energy Information Administration (EIA)

Pennsylvania Percent of Historical Gas Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Florida Percent of Historical Gas Wells by Production Rate Bracket  

U.S. Energy Information Administration (EIA)

Florida Percent of Historical Gas Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

282

California Percent of Historical Oil Wells by Production Rate Bracket  

U.S. Energy Information Administration (EIA)

California Percent of Historical Oil Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

283

United States Percent of Historical Gas Wells by Production Rate ...  

U.S. Energy Information Administration (EIA)

United States Percent of Historical Gas Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

284

EIA publishes historical data series on natural gas storage in ...  

U.S. Energy Information Administration (EIA)

The weekly historical inventory data for salt dome storage being released today offer a glimpse of this rapid deliverability, ...

285

Alaska Percent of Historical Gas Wells by Production Rate Bracket  

U.S. Energy Information Administration (EIA)

Alaska Percent of Historical Gas Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

286

Colorado Percent of Historical Oil Wells by Production Rate Bracket  

U.S. Energy Information Administration (EIA)

Colorado Percent of Historical Oil Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

287

Texas Percent of Historical Oil Wells by Production Rate Bracket  

U.S. Energy Information Administration (EIA)

Texas Percent of Historical Oil Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

288

Oklahoma Percent of Historical Oil Wells by Production Rate Bracket  

U.S. Energy Information Administration (EIA)

Oklahoma Percent of Historical Oil Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

289

North Dakota Percent of Historical Oil Wells by Production Rate ...  

U.S. Energy Information Administration (EIA)

North Dakota Percent of Historical Oil Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

290

Wyoming Percent of Historical Oil Wells by Production Rate Bracket  

U.S. Energy Information Administration (EIA)

Wyoming Percent of Historical Oil Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

291

Florida Percent of Historical Oil Wells by Production Rate Bracket  

U.S. Energy Information Administration (EIA)

Florida Percent of Historical Oil Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

292

Michigan Percent of Historical Oil Wells by Production Rate Bracket  

U.S. Energy Information Administration (EIA)

Michigan Percent of Historical Oil Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

293

United States Percent of Historical Oil Wells by Production Rate ...  

U.S. Energy Information Administration (EIA)

United States Percent of Historical Oil Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

294

Federal Gulf Percent of Historical Oil Wells by Production Rate ...  

U.S. Energy Information Administration (EIA)

Federal Gulf Percent of Historical Oil Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

295

South Dakota Percent of Historical Oil Wells by Production Rate ...  

U.S. Energy Information Administration (EIA)

South Dakota Percent of Historical Oil Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

296

Texas Percent of Historical Gas Wells by Production Rate Bracket  

U.S. Energy Information Administration (EIA)

Texas Percent of Historical Gas Wells by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

297

A Framework for Historic Bridge Preservation  

E-Print Network (OSTI)

In an inevitably occurring process, bridges possessing historic, artistic, and engineering significance deteriorate and must be maintained and rehabilitated in order to be kept in service. Ideally, all potentially significant bridges would be properly preserved and continue to beautify and bring character to their surroundings for years to come. However, funding is currently limited for transportation projects in general, and even more so for historic bridge preservation, which some may consider less critical in comparison to other transportation needs. Because of this limitation on resources, it is important that bridge-owning agencies use proper planning and management strategies in order to make the best use of available funding. This thesis presents a framework designed to assist agencies in this process. The framework is devised specifically for TxDOT for use in Tarrant County, Texas, but can be used as a model for agencies anywhere with some modifications to fit the inventory under evaluation. Included in the framework are a methodology for prioritization of bridges within an inventory, guidance on financial and legal procedures, identification of potential funding sources, summary and review of condition assessment practices and bridge mitigation strategies, a template for individual bridge preservation plans, and a framework for resource allocation within a bridge inventory. It can be concluded from this research that early detection of defects, preventive maintenance, condition assessment beyond routine inspection, adjustment of evaluation methodology, and use of engineering judgment when using numerical evaluation methods are critical components of proper management of historic bridges.

Puls, Eric Mark

2013-08-01T23:59:59.000Z

298

Guidelines for the Development of Historic Properties Management Plans For  

E-Print Network (OSTI)

Section 106 of the National Historic Preservation Act (NHPA) requires the Federal Energy Regulatory Commission (FERC or Commission) to take into account the effect of its undertakings on historic properties and to afford the Advisory Council on Historic Preservation (Council) a reasonable opportunity to comment. An undertaking includes

unknown authors

2002-01-01T23:59:59.000Z

299

Frequency Monitoring and Simulation Analysis for Historical Structures Being Retrofitted  

Science Conference Proceedings (OSTI)

Many historical structures now need to be retrofitted to meet the requirements of fast developing cities. To ensure the safety of a historical masonry building during its retrofitting, natural frequency of the structure was measured through ambient vibrating ... Keywords: Historical masonry building, Retrofit, Monitoring, Simulation

Chao Wang, Bin Peng, Peng Wang

2013-01-01T23:59:59.000Z

300

Earth Hour 2009: March 28, 8:30-9:30 PM Local Time | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Earth Hour 2009: March 28, 8:30-9:30 PM Local Time Earth Hour 2009: March 28, 8:30-9:30 PM Local Time Earth Hour 2009: March 28, 8:30-9:30 PM Local Time March 27, 2009 - 6:00am Addthis John Lippert The city of Greenbelt, Maryland, where I live, is living up to its "green" name by participating in Earth Hour. This global event asks everyone to "go dark" for an hour to make a powerful statement of concern about climate change. The city will be turning off all non-essential lights in municipal buildings. Residents are requested to turn off their lights (and other energy-consuming appliances). The Greenbelt Advisory Committee on Environmental Sustainability, which advises the mayor and city council and which I chair, will be sponsoring a flashlight walk around Old Greenbelt during Earth Hour. My wife and I will

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Earth Hour 2009: March 28, 8:30-9:30 PM Local Time | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Earth Hour 2009: March 28, 8:30-9:30 PM Local Time Earth Hour 2009: March 28, 8:30-9:30 PM Local Time Earth Hour 2009: March 28, 8:30-9:30 PM Local Time March 27, 2009 - 6:00am Addthis John Lippert The city of Greenbelt, Maryland, where I live, is living up to its "green" name by participating in Earth Hour. This global event asks everyone to "go dark" for an hour to make a powerful statement of concern about climate change. The city will be turning off all non-essential lights in municipal buildings. Residents are requested to turn off their lights (and other energy-consuming appliances). The Greenbelt Advisory Committee on Environmental Sustainability, which advises the mayor and city council and which I chair, will be sponsoring a flashlight walk around Old Greenbelt during Earth Hour. My wife and I will

302

MTS Table Top Load frame  

NLE Websites -- All DOE Office Websites (Extended Search)

MTS Table Top Load frame MTS Table Top Load frame The Non-destructive Evaluation group operates an MTS Table Top Load frame for ultimate strength and life cycle testing of various ceramic, ceramic-matrix (FGI), carbon, carbon fiber, cermet (CMC) and metal alloy engineering samples. The load frame is a servo-hydraulic type designed to function in a closed loop configuration under computer control. The system can perform non-cyclic, tension, compression and flexure testing and cyclic fatigue tests. The system is comprised of two parts: * The Load Frame and * The Control System. Load Frame The Load Frame (figure 1) is a cross-head assembly which includes a single moving grip, a stationary grip and LVDT position sensor. It can generate up to 25 kN (5.5 kip) of force in the sample under test and can

303

Status of Jefferson Lab's Load Locked Polarized Electron Beam  

DOE Green Energy (OSTI)

A new 100 kV load locked polarized electron gun has been built at Jefferson Lab. The gun is installed in a test stand on a beam line that resembles the first few meters of the CEBAF nuclear physics photoinjector. With this gun, a GaAs photocathode can be loaded from atmosphere, hydrogen cleaned, activated and taken to high voltage in less than 8 hours. The gun is a three chamber design, with all of the moving parts remaining at ground potential during gun operation. Studies of gun performance, photocathode life times, transverse emittance at high bunch charge, helicity correlated effects and beam polarizations from new photocathode samples will all be greatly facilitated by the use of this load locked gun.

M.L. Stutzman; P. Adderley; M. Baylac; J. Clark; A. Day; J. Grames; J. Hansknecht; M. Poelker

2002-09-01T23:59:59.000Z

304

Forecasting electricity load demand: analysis of the 2001 rationing period  

E-Print Network (OSTI)

CEPEL e UENF. Abstract. This paper studies the electricity load demand behavior during the 2001 rationing period, which was implemented because of the Brazilian energetic crisis. The hourly data refers to a utility situated in the southeast of the country. We use the model proposed by Soares and Souza (2003), making use of generalized long memory to model the seasonal behavior of the load. The rationing period is shown to have imposed a structural break in the series, decreasing the load at about 20%. Even so, the forecast accuracy is decreased only marginally, and the forecasts rapidly readapt to the new situation. The forecast errors from this model also permit verifying the public response to pieces of information released regarding the crisis.

Leonardo Rocha Souza; Lacir Jorge Soares; Leonardo Rocha Souza; Epge Fundação; Getúlio Vargas; Lacir Jorge Soares

2003-01-01T23:59:59.000Z

305

Customer Strategies for Responding to Day-Ahead Market Hourly Electricity Pricing  

E-Print Network (OSTI)

facilities that receive electricity service from Niagaraperiods is your facility’s electricity use highest? ( CHECKthe next day’s hourly electricity prices? ( CHECK ONLY ONE )

2005-01-01T23:59:59.000Z

306

Customer Strategies for Responding to Day-Ahead Market Hourly Electricity Pricing  

E-Print Network (OSTI)

next day’s hourly electricity prices? ( CHECK ONLY ONE ) 1.to Real Time Electricity Prices, Unpublished Manuscript atahead Wholesale Market Electricity Prices: Case Study of RTP

2005-01-01T23:59:59.000Z

307

Analysis of Sub-Hourly Ramping Impacts of Wind Energy and Balancing Area Size: Preprint  

DOE Green Energy (OSTI)

In this paper, we analyze sub-hourly ramping requirements and the benefit of combining Balancing Authority operations with significant wind penetrations.

Milligan, M.; Kirby, B.

2008-06-01T23:59:59.000Z

308

Customer Strategies for Responding to Day-Ahead Market Hourly Electricity Pricing  

E-Print Network (OSTI)

nature of electric service and usage, defining the hoursElectric. 12 The resulting evaluation report estimated elasticities and found measurable reductions in energy usage

2005-01-01T23:59:59.000Z

309

Intra-hour Direct Normal Irradiance solar forecasting using genetic programming  

E-Print Network (OSTI)

UNIVERSITY OF CALIFORNIA, SAN DIEGO Intra-hour Direct NormalChair University of California, San Diego iii TABLE OFRPS,” Technical report, California Independent System

Queener, Benjamin Daniel

2012-01-01T23:59:59.000Z

310

Savannah River National Laboratory Meets with Historically Black Colleges  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savannah River National Laboratory Meets with Historically Black Savannah River National Laboratory Meets with Historically Black Colleges and Universities Savannah River National Laboratory Meets with Historically Black Colleges and Universities February 1, 2013 - 9:00am Addthis South Carolina State University students William Dumpson, left, and Alejandra Chirino, center, talk with Savannah River National Laboratory Director Dr. Terry Michalske at a recent research exchange involving the laboratory and seven historically black colleges and universities. South Carolina State University students William Dumpson, left, and Alejandra Chirino, center, talk with Savannah River National Laboratory Director Dr. Terry Michalske at a recent research exchange involving the laboratory and seven historically black colleges and universities.

311

Savannah River National Laboratory Meets with Historically Black Colleges  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savannah River National Laboratory Meets with Historically Black Savannah River National Laboratory Meets with Historically Black Colleges and Universities Savannah River National Laboratory Meets with Historically Black Colleges and Universities February 1, 2013 - 9:00am Addthis South Carolina State University students William Dumpson, left, and Alejandra Chirino, center, talk with Savannah River National Laboratory Director Dr. Terry Michalske at a recent research exchange involving the laboratory and seven historically black colleges and universities. South Carolina State University students William Dumpson, left, and Alejandra Chirino, center, talk with Savannah River National Laboratory Director Dr. Terry Michalske at a recent research exchange involving the laboratory and seven historically black colleges and universities.

312

Preconditioning Outside Air: Cooling Loads from Building Ventilation  

E-Print Network (OSTI)

HVAC equipment manufacturers, specifiers and end users interacting in the marketplace today are only beginning to address the series of issues promulgated by the increased outside air requirements in ASHRAE Standard 62- 1989, "Ventilation for Acceptable Indoor Air Quality", that has cascaded into building codes over the early to mid 1990's. There has been a twofold to fourfold increase in outside air requirements for many commercial building applications, compared to the 1981 version of the standard. To mitigate or nullify these additional weather loads, outdoor air preconditioning technologies are being promoted in combination with conventional HVAC operations downstream as a means to deliver the required fresh air and control humidity indoors. Preconditioning is the term applied for taking outside air to the indoor air setpoint (dry bulb temperature and relative humidity). The large humidity loads from outside air can now be readily recognized and quantified at cooling design point conditions using the extreme humidity ratios/dew points presented in the ASHRAE Handbook of Fundamentals Chapter 26 "Climatic Design Information". This paper presents an annual index called the Ventilation Load Index (VLI), recently developed by the Gas Research Institute (GRI) that measures the magnitude of latent (and sensible) loads for preconditioning outside air to indoor space conditions over the come of an entire year. The VLI has units of ton-hrs/scfm of outside air. The loads are generated using new weather data binning software called ~BinMaker, also from GRI, that organizes the 239 city, 8760 hour by hour, TMY2 weather data into user selected bidtables. The VLI provides a simple methodology for accessing the cooling load impact of increased ventilation air volumes and a potential basis for defining a "humid" climate location.

Kosar, D.

1998-01-01T23:59:59.000Z

313

Web Version of the Artificial Neural Network Short Term Load Forecaster (WebANNSTLF 6.0)  

Science Conference Proceedings (OSTI)

The EPRI-developed ANNSTLF (Artificial Neural Network Short-Term Load Forecaster) is a neural-network load forecasting software system that uses historical load and weather parameters to predict future load values. EPRI has upgraded the most recent desktop version of the software (ANNSTLF 5.1) to a web-based version (WebANNSTLF 6.0). The new version, which retains almost all the functionally of ANNSTLF 5.1, features a web-based user interface that makes it possible to exploit a wide range of web services.

2007-09-17T23:59:59.000Z

314

Vehicle Technologies Office: Fact #599: November 30, 2009 Historical Trend  

NLE Websites -- All DOE Office Websites (Extended Search)

9: November 30, 9: November 30, 2009 Historical Trend for Light Vehicle Sales to someone by E-mail Share Vehicle Technologies Office: Fact #599: November 30, 2009 Historical Trend for Light Vehicle Sales on Facebook Tweet about Vehicle Technologies Office: Fact #599: November 30, 2009 Historical Trend for Light Vehicle Sales on Twitter Bookmark Vehicle Technologies Office: Fact #599: November 30, 2009 Historical Trend for Light Vehicle Sales on Google Bookmark Vehicle Technologies Office: Fact #599: November 30, 2009 Historical Trend for Light Vehicle Sales on Delicious Rank Vehicle Technologies Office: Fact #599: November 30, 2009 Historical Trend for Light Vehicle Sales on Digg Find More places to share Vehicle Technologies Office: Fact #599: November 30, 2009 Historical Trend for Light Vehicle Sales on

315

Geographical extrapolation of typical hourly weather data for energy calculation in buildings  

E-Print Network (OSTI)

FOR REAL 1951 YEARS PASSIVE HOUSES DAILY LOADS FOR REAL 1951Requirements for Real Year Passive Houses DAILY LOADS FORranch house of 112 m^ (1,200 ft^), a more massive passive

Arens, Edward A; Flynn, Larry E; Nall, Daniel N; Ruberg, Kalev

1980-01-01T23:59:59.000Z

316

Historical hydronuclear testing: Characterization and remediation technologies  

SciTech Connect

This report examines the most current literature and information available on characterization and remediation technologies that could be used on the Nevada Test Site (NTS) historical hydronuclear test areas. Historical hydronuclear tests use high explosives and a small amount of plutonium. The explosion scatters plutonium within a contained subsurface environment. There is currently a need to characterize these test areas to determine the spatial extent of plutonium in the subsurface and whether geohydrologic processes are transporting the plutonium away from the event site. Three technologies were identified to assist in the characterization of the sites. These technologies are the Pipe Explorer{trademark}, cone penetrometer, and drilling. If the characterization results indicate that remediation is needed, three remediation technologies were identified that should be appropriate, namely: capping or sealing the surface, in situ grouting, and in situ vitrification. Capping the surface would prevent vertical infiltration of water into the soil column, but would not restrict lateral movement of vadose zone water. Both the in situ grouting and vitrification techniques would attempt to immobilize the radioactive contaminants to restrict or prevent leaching of the radioactive contaminants into the groundwater. In situ grouting uses penetrometers or boreholes to inject the soil below the contaminant zone with low permeability grout. In situ vitrification melts the soil containing contaminants into a solid block. This technique would provide a significantly longer contaminant immobilization, but some research and development would be required to re-engineer existing systems for use at deep soil depths. Currently, equipment can only handle shallow depth vitrification. After existing documentation on the historical hydronuclear tests have been reviewed and the sites have been visited, more specific recommendations will be made.

Shaulis, L.; Wilson, G.; Jacobson, R.

1997-09-01T23:59:59.000Z

317

Load Management: Opportunity or Calamity?  

E-Print Network (OSTI)

After the change in the economics of generating electricity which took place in 1973, many utilities are examining options to hold down their costs. One fact which is clear is that the difference between peak and off peak generating costs is much larger now than prior to 1973. Utilities are examining two options which can be termed load management. One option is to control discretionary loads during peak periods. Cycling of residential water heaters or shutting off industrial electric furnaces during peak periods are both examples of load control which lower the costs borne by the utility. The other option is the use of seasonal surcharges or time-of-day rates to induce customers to alter their usage patterns. Both these load management options focus on reducing utility costs overall without regard to the cost to the consumers affected by the load management options. The issue, then, is whether industrial customers can find opportunities to lower their costs under load management.

Males, R.; Hassig, N.

1981-01-01T23:59:59.000Z

318

Analysis and Synthesis of Load Forecasting Data for Renewable Integration Studies: Preprint  

SciTech Connect

As renewable energy constitutes greater portions of the generation fleet, the importance of modeling uncertainty as part of integration studies also increases. In pursuit of optimal system operations, it is important to capture not only the definitive behavior of power plants, but also the risks associated with systemwide interactions. This research examines the dependence of load forecast errors on external predictor variables such as temperature, day type, and time of day. The analysis was utilized to create statistically relevant instances of sequential load forecasts with only a time series of historic, measured load available. The creation of such load forecasts relies on Bayesian techniques for informing and updating the model, thus providing a basis for networked and adaptive load forecast models in future operational applications.

Steckler, N.; Florita, A.; Zhang, J.; Hodge, B. M.

2013-11-01T23:59:59.000Z

319

Dynamic load balancing of applications  

DOE Patents (OSTI)

An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated.

Wheat, Stephen R. (Albuquerque, NM)

1997-01-01T23:59:59.000Z

320

Dynamic load balancing of applications  

DOE Patents (OSTI)

An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers is disclosed. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated. 13 figs.

Wheat, S.R.

1997-05-13T23:59:59.000Z

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Quantification of Variability and Uncertainty in Hourly NOx Emissions from Coal-Fired Power Plants  

E-Print Network (OSTI)

1 Quantification of Variability and Uncertainty in Hourly NOx Emissions from Coal-Fired Power to quantify variability and uncertainty for NOx emissions from coal-fired power plants. Data for hourly NOx Uncertainty, Variability, Emission Factors, Coal-Fired Power Plants, NOx emissions, Regression Models

Frey, H. Christopher

322

Multi-hour network planning based on domination between sets of traffic matrices  

Science Conference Proceedings (OSTI)

In multi-hour network design, periodic traffic variations along time are considered in the dimensioning process. Then, the non coincidence of traffic peaks along the day or the week can be exploited. This paper investigates the application of the traffic ... Keywords: Multi-hour traffic, Network planning, Traffic domination

P. Pavon-Marino; B. Garcia-Manrubia; R. Aparicio-Pardo

2011-02-01T23:59:59.000Z

323

Optimal Multi-scale Capacity Planning under Hourly Varying Electricity Prices  

E-Print Network (OSTI)

1 Optimal Multi-scale Capacity Planning under Hourly Varying Electricity Prices Sumit Mitra Ignacio;2 Motivation of this work · Deregulation of the electricity markets caused electricity prices to be highly? (retrofit) · Challenge: Multi-scale nature of the problem! Hourly varying electricity prices vs. 10-15 years

Grossmann, Ignacio E.

324

Cloudy Sky Version of Bird's Broadband Hourly Clear Sky Model (Presentation)  

DOE Green Energy (OSTI)

Presentation on Bird's Broadband Hourly Clear Sky Model given by NREL's Daryl Myers at SOLAR 2006. The objective of this report is to produce ''all sky'' modeled hourly solar radiation. This is based on observed cloud cover data using a SIMPLE model.

Myers, D.

2006-08-01T23:59:59.000Z

325

Customization of the EPRI Artificial Neural Network Short-Term Load Forecaster (ANNSTLF) and User Support for the California Independent System Operator (CA-ISO)  

Science Conference Proceedings (OSTI)

Load forecasting is an important part of power system planning and operation. In the past, forecasting was achieved by extrapolating existing load data combined with other influencing factors. This method is no longer accurate enough. The Artificial Neural Network Short-Term Load Forecaster (ANNSTLF) is a tool for the quick and accurate prediction of hourly loads that provides the level of accuracy required by today's complex and competitive power markets. This report describes all the deliverables for t...

2002-11-19T23:59:59.000Z

326

Alaska Village Electric Load Calculator  

DOE Green Energy (OSTI)

As part of designing a village electric power system, the present and future electric loads must be defined, including both seasonal and daily usage patterns. However, in many cases, detailed electric load information is not readily available. NREL developed the Alaska Village Electric Load Calculator to help estimate the electricity requirements in a village given basic information about the types of facilities located within the community. The purpose of this report is to explain how the load calculator was developed and to provide instructions on its use so that organizations can then use this model to calculate expected electrical energy usage.

Devine, M.; Baring-Gould, E. I.

2004-10-01T23:59:59.000Z

327

High-Power Rf Load  

DOE Patents (OSTI)

A compact high-power RF load comprises a series of very low Q resonators, or chokes [16], in a circular waveguide [10]. The sequence of chokes absorb the RF power gradually in a short distance while keeping the bandwidth relatively wide. A polarizer [12] at the input end of the load is provided to convert incoming TE.sub.10 mode signals to circularly polarized TE.sub.11 mode signals. Because the load operates in the circularly polarized mode, the energy is uniformly and efficiently absorbed and the load is more compact than a rectangular load. Using these techniques, a load having a bandwidth of 500 MHz can be produced with an average power dissipation level of 1.5 kW at X-band, and a peak power dissipation of 100 MW. The load can be made from common lossy materials, such as stainless steel, and is less than 15 cm in length. These techniques can also produce loads for use as an alternative to ordinary waveguide loads in small and medium RF accelerators, in radar systems, and in other microwave applications. The design is easily scalable to other RF frequencies and adaptable to the use of other lossy materials.

Tantawi, Sami G. (San Mateo, CA); Vlieks, Arnold E. (Livermore, CA)

1998-09-01T23:59:59.000Z

328

Mirant: Ambient 24 Hour SO2 Values: Model vs Monitor | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Mirant: Ambient 24 Hour SO2 Values: Model vs Monitor Mirant: Ambient 24 Hour SO2 Values: Model vs Monitor Mirant: Ambient 24 Hour SO2 Values: Model vs Monitor Docket No. EO-05-01: Mirant: Ambient 24 Hour SO2 Values: Model vs Monitor, March 2002 to November 2004, showing the model overprediction Mirant: Ambient 24 Hour SO2 Values: Model vs Monitor More Documents & Publications Comments on Department of Energy's Emergency Order To Resume Limited Operation at Mirant's Potomac River Generating Station and Proposed Mirant Compliance Plan Answer of Potomac Electric Power Company and PJM lnterconnection, L.L.C. to the October 6, 2005 motion filed by the Virginia Department of Environmental Quality Special Environmental Analysis For Actions Taken under U.S. Department of Energy Emergency Orders Regarding Operation of the Potomac River Generating

329

Derivation of 24-Hour Average SO2, Background for the Update 1 Report |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Derivation of 24-Hour Average SO2, Background for the Update 1 Derivation of 24-Hour Average SO2, Background for the Update 1 Report Derivation of 24-Hour Average SO2, Background for the Update 1 Report Docket No. EO-05-01. As supporting documentation for "Update 1 to: A Dispersion Modeling Analysis of Downwash from Mirant's Potomac River Power Plant: Modeling Unit 1 Emissions in a Cycling Mode" this memo documents the fact that the observed 24-hour SO2 background concentrations during periods when meteorological conditions produce the highest impacts from Unit 1. Derivation of 24-Hour Average SO2, Background for the Update 1 Report More Documents & Publications Review of the ENSR Report Titled "Update 1 to: A Dispersion Modeling Analysis of Downwash from Mirant's Potomac River Power Plant"

330

Investigation of residential central air conditioning load shapes in NEMS  

SciTech Connect

This memo explains what Berkeley Lab has learned about how the residential central air-conditioning (CAC) end use is represented in the National Energy Modeling System (NEMS). NEMS is an energy model maintained by the Energy Information Administration (EIA) that is routinely used in analysis of energy efficiency standards for residential appliances. As part of analyzing utility and environmental impacts related to the federal rulemaking for residential CAC, lower-than-expected peak utility results prompted Berkeley Lab to investigate the input load shapes that characterize the peaky CAC end use and the submodule that treats load demand response. Investigations enabled a through understanding of the methodology by which hourly load profiles are input to the model and how the model is structured to respond to peak demand. Notably, it was discovered that NEMS was using an October-peaking load shape to represent residential space cooling, which suppressed peak effects to levels lower than expected. An apparent scaling down of the annual load within the load-demand submodule was found, another significant suppressor of the peak impacts. EIA promptly responded to Berkeley Lab's discoveries by updating numerous load shapes for the AEO2002 version of NEMS; EIA is still studying the scaling issue. As a result of this work, it was concluded that Berkeley Lab's customary end-use decrement approach was the most defensible way for Berkeley Lab to perform the recent CAC utility impact analysis. This approach was applied in conjunction with the updated AEO2002 load shapes to perform last year's published rulemaking analysis. Berkeley Lab experimented with several alternative approaches, including modifying the CAC efficiency level, but determined that these did not sufficiently improve the robustness of the method or results to warrant their implementation. Work in this area will continue in preparation for upcoming rulemakings for the other peak coincident end uses, commercial air conditioning and distribution transformers.

Hamachi LaCommare, Kristina; Marnay, Chris; Gumerman, Etan; Chan, Peter; Rosenquist, Greg; Osborn, Julie

2002-05-01T23:59:59.000Z

331

Historical Information O C P G  

Office of Legacy Management (LM)

Historical Information Historical Information ~ O C P G L 2 FILE 8 H.5 ' Radioactivity. Book 1 COPY DISCLAIMER Portions of this document may be illegible in electronic image products. Images are produced from the best available original document. TEST PLAN . . FIELD TEST FT-60 RADIOACTIVITY SAMPLING FOR . . . . . . ON-SITE INSPECTION (- ; \ - 28 August 1969 ~ ~ The F i e l d Operations D i v i s i o n of the Weapons E v a l u a t i o n and Control Bureau assumes o v e r a l l r e s p o n s i b i l i t y for the development o f t h i s document. ( ' This Plan i s part of a broad program o f . r e s e a r c h on inspe'ction and v e r i f i c a t i o n . . a n d does n o t express a U. S . p o s i t i o n . , j - - 'Prepared By FIELD OPERATIONS DIVISION WEAPONS EVALUATION AND CONTROL BUREAU UNITED STATES A R M S CONTROL AND DISARMAMENT AGENCY SYNOPSIS The r

332

Static identification of delinquent loads  

E-Print Network (OSTI)

The effective use of processor caches is crucial to the performance of applications. It has been shown that cache misses are not evenly distributed throughout a program. In applications running on RISC-style processors, a small number of delinquent load instructions are responsible for most of the cache misses. Identification of delinquent loads is the key to the success of many cache optimization and prefetching techniques. In this paper, we propose a method for identifying delinquent loads that can be implemented at compile time. Our experiments over eighteen benchmarks from the SPEC suite shows that our proposed scheme is stable across benchmarks, inputs, and cache structures, identifying an average of 10 % of the total number of loads in the benchmarks we tested that account for over 90 % of all data cache misses. As far as we know, this is the first time a technique for static delinquent load identification with such a level of precision and coverage has been reported. While comparable techniques can also identify load instructions that cover 90 % of all data cache misses, they do so by selecting over 50 % of all load instructions in the code, resulting in a high number of false positives. If basic block profiling is used in conjunction with our heuristic, then our results show that it is possible to pin down just 1.3 % of the load instructions that account for 82 % of all data cache misses. 1.

Vlad-mihai Panait; Amit Sasturkar Ý

2004-01-01T23:59:59.000Z

333

LOAD FORECASTING Eugene A. Feinberg  

E-Print Network (OSTI)

's electricity price forecasting model, produces forecast of gas demand consistent with electric load. #12Gas demand Council's Market Price of Electricity Forecast Natural GasDemand Electric Load Aggregating Natural between the natural gas and electricity and new uses of natural gas emerge. T natural gas forecasts

Feinberg, Eugene A.

334

Wind load reduction for heliostats  

DOE Green Energy (OSTI)

This report presents the results of wind-tunnel tests supported through the Solar Energy Research Institute (SERI) by the Office of Solar Thermal Technology of the US Department of Energy as part of the SERI research effort on innovative concentrators. As gravity loads on drive mechanisms are reduced through stretched-membrane technology, the wind-load contribution of the required drive capacity increases in percentage. Reduction of wind loads can provide economy in support structure and heliostat drive. Wind-tunnel tests have been directed at finding methods to reduce wind loads on heliostats. The tests investigated primarily the mean forces, moments, and the possibility of measuring fluctuating forces in anticipation of reducing those forces. A significant increase in ability to predict heliostat wind loads and their reduction within a heliostat field was achieved.

Peterka, J.A.; Hosoya, N.; Bienkiewicz, B.; Cermak, J.E.

1986-05-01T23:59:59.000Z

335

Exhibits, Museums, Historic Facilities, and Public Tours | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

History » Historical Resources » History » Historical Resources » Exhibits, Museums, Historic Facilities, and Public Tours Exhibits, Museums, Historic Facilities, and Public Tours Exhibits, Museums, Historic Facilities, and Public Tours The Department of Energy (DOE) supports exhibits, museums, and historic facilities across the country dedicated to displaying and interpreting the history of the Department and its scientific and technological missions and accomplishments. Public tours are also available at some of the Department's sites. The Department's headquarters building and some of the DOE field sites have public visitor centers. The visitor centers frequently display history exhibits. The cornerstone of the public visitor center in the lobby at the Forrestal headquarters in Washington, D.C., is a major permanent Manhattan

336

Vehicle Technologies Office: Fact #545: November 17, 2008 Historical  

NLE Websites -- All DOE Office Websites (Extended Search)

5: November 17, 5: November 17, 2008 Historical Alternative Fuel Prices Compared to Gasoline and Diesel to someone by E-mail Share Vehicle Technologies Office: Fact #545: November 17, 2008 Historical Alternative Fuel Prices Compared to Gasoline and Diesel on Facebook Tweet about Vehicle Technologies Office: Fact #545: November 17, 2008 Historical Alternative Fuel Prices Compared to Gasoline and Diesel on Twitter Bookmark Vehicle Technologies Office: Fact #545: November 17, 2008 Historical Alternative Fuel Prices Compared to Gasoline and Diesel on Google Bookmark Vehicle Technologies Office: Fact #545: November 17, 2008 Historical Alternative Fuel Prices Compared to Gasoline and Diesel on Delicious Rank Vehicle Technologies Office: Fact #545: November 17, 2008 Historical Alternative Fuel Prices Compared to Gasoline and Diesel on Digg

337

Manhattan Project National Historical Park | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Manhattan Project National Historical Park Manhattan Project National Historical Park Manhattan Project National Historical Park The Department, as the direct descendent of the Manhattan Engineer District, owns and manages the Federal properties at most of the major Manhattan Project sites, including Oak Ridge, Tennessee; Hanford, Washington; and Los Alamos, New Mexico. For over a decade, the Department, in cooperation with other Federal agencies, state and local governments, and other stakeholders, has pursued the possibility of including its most significant Manhattan Project properties within a Manhattan Project National Historical Park. A panel of distinguished historic preservation experts convened in 2001 by the Advisory Council on Historic Preservation at the request of the Department of Energy recommended that the "ultimate goal" for

338

Washington State Department of Archaeology and Historic Preservation | Open  

Open Energy Info (EERE)

Washington State Department of Archaeology and Historic Preservation Washington State Department of Archaeology and Historic Preservation Jump to: navigation, search Name Washington State Department of Archaeology and Historic Preservation Short Name DAHP Address 1063 South Capitol Way, Suite 106 Place Olympia, Washington Zip 98504 Phone number 360-586-3065 Website http://www.dahp.wa.gov/ References DAHP Website[1] This article is a stub. You can help OpenEI by expanding it. The Department of Archaeology and Historic Preservation is Washington's primary agency for historic preservation. This agency oversees the procedures for cultural resource discovery. References ↑ "DAHP Website" Retrieved from "http://en.openei.org/w/index.php?title=Washington_State_Department_of_Archaeology_and_Historic_Preservation&oldid=694965"

339

Average Data for Each Choke Setting (before 24-May 2010 06:00), 6-hour average (  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Average Data for Each Choke Setting (before 24-May 2010 06:00), 6-hour average (after 24-May 2010 06:00):" Average Data for Each Choke Setting (before 24-May 2010 06:00), 6-hour average (after 24-May 2010 06:00):" ,,"Choke","Average","Average","Fluid","Methanol","Water","Oil","Gas","Hyd. Eq.","Gas" ,"Choke","Setting","Upstream","Upstream","Recovery","Recovery","Recovery","Recovery","Recovery","Recovery","Recovery" "Date and Time","Setting","Duration","Pressure","Temp.","Rate","Rate","Rate","Rate","Rate","Rate","Portion" "dd-mmm-yy","(64ths)","(hours)","(psia)","(degF)","(bfpd)","(bfpd)","(bwpd)","(bopd)","(mmcfpd)","(boepd)","(%)"

340

President Obama Chairs Historic UN Security Council Meeting | National  

National Nuclear Security Administration (NNSA)

Chairs Historic UN Security Council Meeting | National Chairs Historic UN Security Council Meeting | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > About Us > Our History > NNSA Timeline > President Obama Chairs Historic UN Security Council Meeting President Obama Chairs Historic UN Security Council Meeting September 24, 2009

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Utah Percent of Historical Oil Well Production (BOE) by Production ...  

U.S. Energy Information Administration (EIA)

Utah Percent of Historical Oil Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

342

Historic Surface Faulting and Paleoseismicity in the Area of...  

Open Energy Info (EERE)

Historic Surface Faulting and Paleoseismicity in the Area of the 1954 Rainbow Mountain-Stillwater Earthquake Sequence, Central Nevada Jump to: navigation, search OpenEI Reference...

343

California Percent of Historical Oil Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

California Percent of Historical Oil Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

344

Historic preservation : a study in local public administration.  

E-Print Network (OSTI)

?? Do citizen volunteers, sitting on legislatively created local historic architectural review boards, represent a part of the American governance tradition? This study examines the… (more)

Nicolay, John

2007-01-01T23:59:59.000Z

345

Ohio Percent of Historical Gas Well Production (BOE) by Production ...  

U.S. Energy Information Administration (EIA)

Ohio Percent of Historical Gas Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

346

West Virginia Percent of Historical Gas Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

West Virginia Percent of Historical Gas Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

347

Oklahoma Percent of Historical Gas Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

Oklahoma Percent of Historical Gas Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

348

Pennsylvania Percent of Historical Gas Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

Pennsylvania Percent of Historical Gas Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

349

Alaska Federal Oil and Gas Historical Leases | Data.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Federal Oil and Gas Historical Leases Ocean Data Tools Technical Guide Map Gallery Regional Planning Feedback Ocean You are here Data.gov Communities Ocean Data Alaska...

350

Historical Time Line and Information About the Hanford Site  

SciTech Connect

Historical time line of the Hanford Site spanning from 1940 through 1997, including photographs and other information regarding the town sites and living conditions.

Briggs Jr, David

2001-03-07T23:59:59.000Z

351

Texas Percent of Historical Gas Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

Texas Percent of Historical Gas Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

352

Texas Percent of Historical Oil Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

Texas Percent of Historical Oil Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

353

United States Percent of Historical Oil Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

United States Percent of Historical Oil Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

354

United States Percent of Historical Gas Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

United States Percent of Historical Gas Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

355

EIA publishes historical data series on natural gas storage in ...  

U.S. Energy Information Administration (EIA)

In the January 17, 2013 Weekly Natural Gas Storage Report, EIA published historical data back to 2007 showing the breakout of working gas storage in salt caverns ...

356

Michigan Percent of Historical Gas Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

Michigan Percent of Historical Gas Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

357

Historical Carbon Dioxide Record from the Vostok Ice Core  

NLE Websites -- All DOE Office Websites (Extended Search)

Vostok Ice Core Historical Carbon Dioxide Record from the Vostok Ice Core graphics Graphics data Data Investigators J.-M. Barnola, D. Raynaud, C. Lorius Laboratoire de Glaciologie...

358

Historical Carbon Dioxide Record from the Siple Station Ice Core  

NLE Websites -- All DOE Office Websites (Extended Search)

Siple Station Ice Core Historical Carbon Dioxide Record from the Siple Station Ice Core graphics Graphics data Data Investigators A. Neftel, H. Friedli, E. Moor, H. Ltscher, H....

359

Trends and causes of historical wetland loss in coastal ...  

U.S. Energy Information Administration (EIA)

Get this from a library! Trends and causes of historical wetland loss in coastal Louisiana. [Julie Christine Bernier; Geological Survey (U.S.),

360

Alaska Percent of Historical Gas Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

Alaska Percent of Historical Gas Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Historical Renewable Energy Consumption by Energy Use Sector...  

Open Energy Info (EERE)

Historical Renewable Energy Consumption by Energy Use Sector and Energy Source, 1989-2008 Provides annual renewable energy consumption by source and end use between 1989 and 2008....

362

Prime Supplier Report Historical - U.S. Energy Information ...  

U.S. Energy Information Administration (EIA)

Prime Supplier Report Historical. Monthly Report of Prime Supplier Sales of Petroleum Products Sold for Local Consumption. These data measure primary petroleum ...

363

From National Security to Environmental Security: A Historical Overview .  

E-Print Network (OSTI)

??The study attempts to provide a historical approach to the role of the environment in security studies. Contemporary security challenges have shown that the narrow… (more)

Vella, Andre`

2012-01-01T23:59:59.000Z

364

Residential Transportation Historical Data Tables for 1983-2001  

U.S. Energy Information Administration (EIA) Indexed Site

RTECS Historical Data Tables RTECS Historical Data Tables Residential Transportation Historical Data Tables Released: May 2008 Below are historical data tables from the Residential Transportation Energy Consumption Survey (RTECS) and Household Vehicles Energy Use: Latest Data & Trends report. These tables cover the trends in energy consumption for household transportation throughout the survey years. The data focus on several important indicators of demand for transportation: number and type of vehicles per household; vehicle-miles traveled per household and per vehicle; fuel consumption; fuel expenditures; and fuel economy. Excel PDF Trends in Households & Vehicles Table 1. Number of Households with Vehicles excel pdf Table 2. Percent of Households with Vehicles excel pdf

365

Montana Percent of Historical Oil Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

Montana Percent of Historical Oil Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

366

Ohio Percent of Historical Oil Well Production (BOE) by Production ...  

U.S. Energy Information Administration (EIA)

Ohio Percent of Historical Oil Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

367

Florida Percent of Historical Oil Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

Florida Percent of Historical Oil Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

368

Kentucky Percent of Historical Oil Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

Kentucky Percent of Historical Oil Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

369

Arkansas Percent of Historical Oil Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

Arkansas Percent of Historical Oil Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

370

Tennessee Percent of Historical Oil Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

Tennessee Percent of Historical Oil Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

371

West Virginia Percent of Historical Oil Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

West Virginia Percent of Historical Oil Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

372

Colorado Percent of Historical Oil Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

Colorado Percent of Historical Oil Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

373

Missouri Percent of Historical Oil Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

Missouri Percent of Historical Oil Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

374

Wyoming Percent of Historical Oil Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

Wyoming Percent of Historical Oil Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

375

Alaska Percent of Historical Oil Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

Alaska Percent of Historical Oil Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

376

South Dakota Percent of Historical Gas Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

South Dakota Percent of Historical Gas Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

377

New Mexico Percent of Historical Gas Well Production (BOE) by ...  

U.S. Energy Information Administration (EIA)

New Mexico Percent of Historical Gas Well Production (BOE) by Production Rate Bracket. Energy Information Administration (U.S. Dept. of Energy)

378

Historical Natural Gas Annual 1930 Through 1995  

Gasoline and Diesel Fuel Update (EIA)

0 0 Through 1995 Historical Natural Gas Annual Energy Information Administration DOE/EIA-0131(95)/2 November 1996 This publication and other Energy Information Administration (EIA) publications may be purchased from the Superin- tendent of Documents, U.S. Government Printing Office. Telephone orders may be directed to: Superintendent of Documents U.S. Government Printing Office Main Order Desk (202) 512-1800 FAX: (202) 512-2250 8 a.m. to 4:30 p.m., eastern time, M-F All mail orders should be directed to: U.S. Government Printing Office P.O. Box 371954 Pittsburgh, PA 15250-7954 Complimentary subscriptions and single issues are available to certain groups of subscribers, such as public and academic libraries, Federal, State, local and foreign governments, EIA survey respondents, and the media. For further information and for answers to questions

379

Historical river flow rates for dose calculations  

Science Conference Proceedings (OSTI)

Annual average river flow rates are required input to the LADTAP Computer Code for calculating offsite doses from liquid releases of radioactive materials to the Savannah River. The source of information on annual river flow rates used in dose calculations varies, depending on whether calculations are for retrospective releases or prospective releases. Examples of these types of releases are: Retrospective - releases from routine operations (annual environmental reports) and short term release incidents that have occurred. Prospective - releases that might be expected in the future from routine or abnormal operation of existing or new facilities (EIS`s, EID`S, SAR`S, etc.). This memorandum provides historical flow rates at the downstream gauging station at Highway 301 for use in retrospective dose calculations and derives flow rate data for the Beaufort-Jasper and Port Wentworth water treatment plants.

Carlton, W.H.

1991-06-10T23:59:59.000Z

380

A Historical Profile of the Higgs Boson  

Science Conference Proceedings (OSTI)

The Higgs boson was postulated in 1964, and phenomenological studies of its possible production and decays started in the early 1970s, followed by studies of its possible productionin e{sup +} e{sup -}, {anti p}p and pp collisions, in particular. Until recently, the most sensitive searches for the Higgs boson were at LEP between 1989 and 2000, which have been complemented bysearches at the Fermilab Tevatron. The LHC has recently entered the hunt, excluding a Higgs boson over a large range of masses and revealing a tantalizing hint in the range 119 to125 GeV, and there are good prospects that the existence or otherwise of the Higgs boson will soon be established. One of the most attractive possibilities is that the Higgs bosonis accompanied by supersymmetry, though composite options have yet to be excluded. This article reviews some of the key historical developments in Higgs physics over the past half-century.

Ellis, John; Gaillard, Mary K.; Nanopoulos, Dimitri V.

2012-01-31T23:59:59.000Z

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Integrating load management with supply-side operations - A case study  

SciTech Connect

The main topic of this paper analyses and discusses the operational integration of Load Management operations with co-generation, power-pool purchases/sells and other supply-side options, where the common denominator is the hourly short-run marginal cost. The second topic concerns the operational coordination problem between a generating utility and its retail distributors when both parties use load management. The thirds is the interactive impacts of interruptible sales and other demand-side programs on the distribution load curve. The discussion is based on the operational experiences at Skydkraft, the largest investor-owned utility in Sweden.

Edvinsson, M.J.; Nilsson, M.O.

1987-08-01T23:59:59.000Z

382

ELECTRICAL LOAD ANTICIPATOR AND RECORDER  

DOE Patents (OSTI)

A system is described in which an indication of the prevailing energy consumption in an electrical power metering system and a projected power demand for one demand in terval is provided at selected increments of time within the demand interval. Each watt-hour meter in the system is provided with an impulse generator that generates two impulses for each revolution of the meter disc. In each demand interval, for example, one half-hour, of the metering system, the total impulses received from all of the meters are continuously totaled for each 5-minute interval and multiplied by a number from 6 to 1 depending upon which 5- minute interval the impulses were received. This value is added to the total pulses received in the intervals preceding the current 5-minute interval within the half-hour demand interval tc thereby provide an indication of the projected power demand every 5 minutes in the demand interval.

Werme, J.E.

1961-09-01T23:59:59.000Z

383

Electrical load management for the California water system  

DOE Green Energy (OSTI)

To meet its water needs California has developed an extensive system for transporting water from areas with high water runoff to areas with high water demand. This system annually consumes more than 6 billion kilowatt hours (kWh) of electricity for pumping water and produces more than 12 billion kWh/year of hydroelectric power. From the point of view of energy conservation, the optimum operation of the California water supply system would require that pumping be done at night and generation be done during the day. Night pumping would reduce electric power peak load demand and permit the pumps to be supplied with electricity from ''base load'' generating plants. Daytime hydro power generation would augment peak load power generation by fossil-fuel power plants and save fuel. The technical and institutional aspects of this type of electric power load management for water projects are examined for the purpose of explaining some of the actions which might be pursued and to develop recommendations for the California Energy Resources Conservation and Development Commission (ERCDC). The California water supply system is described. A brief description is given of various energy conservation methods, other than load management, that can be used in the management of water resources. An analysis of load management is presented. Three actions for the ERCDC are recommended: the Commission should monitor upcoming power contract negotiations between the utilities and the water projects; it should determine the applicability of the power-pooling provisions of the proposed National Energy Act to water systems; and it should encourage and support detailed studies of load management methods for specific water projects.

Krieg, B.; Lasater, I.; Blumstein, C.

1977-07-01T23:59:59.000Z

384

Nonprofit Organizations: Have Your Los Alamos Employees/Retirees Log Hours  

NLE Websites -- All DOE Office Websites (Extended Search)

Nonprofit Organizations: Have Your Los Alamos Employees/Retirees Log Nonprofit Organizations: Have Your Los Alamos Employees/Retirees Log Hours in VolunteerMatch Community Connections: Our link to Northern New Mexico Communities Latest Issue:Dec. 2013 - Jan. 2014 All Issues » submit Nonprofit Organizations: Have Your Los Alamos Employees/Retirees Log Hours in VolunteerMatch Lab employees and retirees should log their VolunteerMatch hours to benefit local nonprofits. March 1, 2013 Volunteers help fill sandbags during flood season Volunteers help in many different roles including in healthcare. Contacts Editor Linda Anderman Email Community Programs Office Kurt Steinhaus Email So far, employees and retirees have volunteered more than 1.2 million volunteer hours. If you are a nonprofit organization that has Lab employees or retirees as

385

Solar: hourly global horizontal (GHI) and direct normal (DNI) data for  

Open Energy Info (EERE)

Nepal from DLR Nepal from DLR Dataset Summary Description (Abstract): Hourly time series of GHI and DNI for the years 2000, 2002 and 2003 for selected sites in Nepal. The hourly data are stored in ASCII files for each station. Please read the documentation file for additional information. (Purpose): For the selected sites, the hourly time series can be used for the simulation of Photovoltaic (PV)-systems or Concentrating Solar Power (CSP)-systems. Source DLR - Deutsches Zentrum für Luft- und Raumfahrt Date Released October 31st, 2004 (10 years ago) Date Updated November 01st, 2007 (7 years ago) Keywords DLR DNI GEF GHI hourly data Nepal NREL solar SWERA TILT UNEP Data application/zip icon Download data (zip, 1.2 MiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage

386

DOE Awards 265 Million Hours of Supercomputing Time to Advance Leading  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE Awards 265 Million Hours of Supercomputing Time to Advance DOE Awards 265 Million Hours of Supercomputing Time to Advance Leading Scientific Research Projects DOE Awards 265 Million Hours of Supercomputing Time to Advance Leading Scientific Research Projects January 17, 2008 - 10:38am Addthis WASHINGTON, DC -The U.S. Department of Energy's (DOE) Office of Science today announced that 265 million processor-hours were awarded to 55 scientific projects, the largest amount of supercomputing resource awards donated in the Department's history and three times that of last year's award. The projects-with applications from aeronautics to astrophysics, and from climate change to combustion research-were chosen based on their potential breakthroughs in the science and engineering research and their suitability of the project for using supercomputers. These awards will

387

Spatial and Temporal Characteristics of Heavy Hourly Rainfall in the United States  

Science Conference Proceedings (OSTI)

The climatology of heavy rain events from hourly precipitation observations by Brooks and Stensrud is revisited in this study using two high-resolution precipitation datasets that incorporate both gauge observations and radar estimates. Analyses ...

Nathan M. Hitchens; Harold E. Brooks; Russ S. Schumacher

2013-12-01T23:59:59.000Z

388

DOE Awards 265 Million Hours of Supercomputing Time to Advance Leading  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

265 Million Hours of Supercomputing Time to Advance 265 Million Hours of Supercomputing Time to Advance Leading Scientific Research Projects DOE Awards 265 Million Hours of Supercomputing Time to Advance Leading Scientific Research Projects January 17, 2008 - 10:38am Addthis WASHINGTON, DC -The U.S. Department of Energy's (DOE) Office of Science today announced that 265 million processor-hours were awarded to 55 scientific projects, the largest amount of supercomputing resource awards donated in the Department's history and three times that of last year's award. The projects-with applications from aeronautics to astrophysics, and from climate change to combustion research-were chosen based on their potential breakthroughs in the science and engineering research and their suitability of the project for using supercomputers. These awards will

389

Oak Ridge: Approaching 4 Million Safe Work Hours | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ridge: Approaching 4 Million Safe Work Hours Ridge: Approaching 4 Million Safe Work Hours Oak Ridge: Approaching 4 Million Safe Work Hours March 11, 2013 - 12:03pm Addthis Safety inspections are a key element in a nuclear cleanup environment with large pieces of cleanup equipment. Inspections are essential to continuing safety success and reaching new milestones.| Photo courtesy of Oak Ridge Safety inspections are a key element in a nuclear cleanup environment with large pieces of cleanup equipment. Inspections are essential to continuing safety success and reaching new milestones.| Photo courtesy of Oak Ridge David Sheeley Editor/Writer for Environmental Management's Office of External Affairs Workers at URS | CH2M Oak Ridge (UCOR), the prime contractor for EM's Oak Ridge cleanup, are approaching a milestone of 4 million safe work hours

390

Solar: hourly global horizontal (GHI) and direct normal (DNI) data for  

Open Energy Info (EERE)

Ethiopia from DLR Ethiopia from DLR Dataset Summary Description (Abstract): Hourly time series of GHI and DNI for the years 2000, 2001 and 2002 for selected sites in Ethiopia. The hourly data are stored in ASCII files for each station. Please read the documentation file for additional information. (Purpose): For the selected sites, the hourly time series can be used for the simulation of Photovoltaic (PV)-systems or Concentrating Solar Power (CSP)-systems. Source DLR - Deutsches Zentrum für Luft- und Raumfahrt Date Released October 31st, 2004 (10 years ago) Date Updated November 01st, 2007 (7 years ago) Keywords DLR DNI GHI hourly data solar SWERA TILT UNEP Data application/zip icon Download data (zip, 2.1 MiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage

391

WIPP Workers Reach Two Million Man-Hours Without a Lost-Time Accident  

NLE Websites -- All DOE Office Websites (Extended Search)

Workers Reach Two Million Man-Hours Workers Reach Two Million Man-Hours Without a Lost-Time Accident CARLSBAD, N.M., February 22, 2001 - Workers at the U.S. Department of Energy's (DOE) Waste Isolation Pilot Plant (WIPP) reached a safety milestone Feb. 19 by working two million man-hours without a lost-time accident. According to the National Safety Council, facilities with the same industry code as WIPP lose an average of 20.6 workdays (or 164.8 man-hours) a year to accidents. "Safety is at the core of all WIPP operations," said Dr. Inés Triay, Manager of DOE's Carlsbad Field Office. "We are particularly pleased that WIPP workers reached the two million mark during the time in which they mined a new panel and increased shift work." "To make safety a number one priority means more than creating a safe

392

Solar: hourly global horizontal (GHI) and direct normal (DNI) data for  

Open Energy Info (EERE)

Kenya from DLR Kenya from DLR Dataset Summary Description (Abstract): Hourly time series of GHI and DNI for the years 2000, 2001 and 2002 for selected sites in Kenya. The hourly data are stored in ASCII files for each station. Please read the documentation file for additional information. (Purpose): For the selected sites, the hourly time series can be used for the simulation of Photovoltaic (PV)-systems or Concentrating Solar Power (CSP)-systems. Source DLR - Deutsches Zentrum für Luft- und Raumfahrt Date Released October 31st, 2004 (10 years ago) Date Updated November 01st, 2007 (7 years ago) Keywords DLR DNI GEF GHI hourly data Kenya solar SWERA TILT UNEP Data application/zip icon Download data (zip, 3.9 MiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage

393

DOE's Office of Science Awards 95 Million Hours of Supercomputing Time to  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

95 Million Hours of Supercomputing 95 Million Hours of Supercomputing Time to Advance Research in Science, Academia and Industry DOE's Office of Science Awards 95 Million Hours of Supercomputing Time to Advance Research in Science, Academia and Industry January 8, 2007 - 9:59am Addthis WASHINGTON, D.C. - The U.S. Department of Energy's (DOE) Office of Science announced today that 45 projects were awarded a total of 95 million hours of computing time on some of the world's most powerful supercomputers as part of its 2007 Innovative and Novel Computational Impact on Theory and Experiment (INCITE) program. DOE's Under Secretary for Science Dr. Raymond Orbach presented the awards at the Council on Competitiveness in Washington, DC. Supercomputers are playing an increasingly important role in scientific

394

A simple method to downscale daily wind statistics to hourly wind data  

E-Print Network (OSTI)

Wind is the principal driver in the wind erosion models. The hourly wind speed data were generally required for precisely wind erosion modeling. In this study, a simple method to generate hourly wind speed data from daily wind statistics (daily average and maximum wind speeds together or daily average wind speed only) was established. A typical windy location with 3285 days (9 years) measured hourly wind speed data were used to validate the downscaling method. The results showed that the overall agreement between observed and simulated cumulative wind speed probability distributions appears excellent, especially for the wind speeds greater than 5 m s-1 range (erosive wind speed). The results further revealed that the values of daily average erosive wind power density (AWPD) calculated from generated wind speeds fit the counterparts computed from measured wind speeds well with high models' efficiency (Nash-Sutcliffe coefficient). So that the hourly wind speed data can be predicted from daily average and maximu...

Guo, Zhongling

2013-01-01T23:59:59.000Z

395

The Relationships between Network Lightning Surface and Hourly Observations of Thunderstorms  

Science Conference Proceedings (OSTI)

Relationships were established between lightning location data and surface hourly observations of thunderstorms for 132 stations in the northeastern United States. The relationships are based on statistics derived from 2 × 2 contingency tables ...

Ronald M. Reap; Richard E. Orville

1990-01-01T23:59:59.000Z

396

Building Technologies Program: Tax Deduction Qualified Software- Hourly Analysis Program (HAP) version 4.41  

Energy.gov (U.S. Department of Energy (DOE))

Provides required documentation that Hourly Analysis Program (HAP) version 4.41 meets Internal Revenue Code §179D, Notice 2006-52, dated April 10, 2009, for calculating commercial building energy and power cost savings.

397

Building Technologies Program: Tax Deduction Qualified Software- Hourly Analysis Program (HAP) version 4.31  

Energy.gov (U.S. Department of Energy (DOE))

Provides required documentation that Hourly Analysis Program (HAP) version 4.31 meets Internal Revenue Code §179D, Notice 2006-52, dated June 2, 2006, for calculating commercial building energy and power cost savings.

398

Cluster Analysis of Hourly Wind Measurements to Reveal Synoptic Regimes Affecting Air Quality  

Science Conference Proceedings (OSTI)

A clustering algorithm is developed to study hourly, ground-level wind measurements obtained from a network of monitoring stations positioned throughout the San Francisco Bay Area of California. A statistical model based on principal components ...

Scott Beaver; Ahmet Palazoglu

2006-12-01T23:59:59.000Z

399

Building Technologies Program: Tax Deduction Qualified Software- Hourly Analysis Program (HAP) version 4.40  

Energy.gov (U.S. Department of Energy (DOE))

Provides required documentation that Hourly Analysis Program (HAP) version 4.40 meets Internal Revenue Code §179D, Notice 2006-52, dated April 10, 2009, for calculating commercial building energy and power cost savings.

400

Building Technologies Program: Tax Deduction Qualified Software- Hourly Analysis Program (HAP) version 4.34  

Energy.gov (U.S. Department of Energy (DOE))

Provides required documentation that Hourly Analysis Program (HAP) version 4.34 meets Internal Revenue Code §179D, Notice 2006-52, dated June 2, 2006, for calculating commercial building energy and power cost savings.

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Building Technologies Program: Tax Deduction Qualified Software- Hourly Analysis Program (HAP) version 4.50  

Energy.gov (U.S. Department of Energy (DOE))

Provides required documentation that Hourly Analysis Program (HAP) version 4.50 meets Internal Revenue Code §179D, Notice 2006-52, dated June 2, 2006, for calculating commercial building energy and power cost savings.

402

How much carbon dioxide (CO 2 ) is produced per kilowatt-hour ...  

U.S. Energy Information Administration (EIA)

How much carbon dioxide (CO 2) is produced per kilowatt-hour when generating electricity with fossil fuels? You can calculate the amount of CO2 produced per kWh for ...

403

NREL Develops Sub-Hour Solar Power Data Set (Fact Sheet), NREL...  

NLE Websites -- All DOE Office Websites (Extended Search)

Sub-Hour Solar Power Data Set NREL data will help utilities incorporate solar energy into their electric power systems. Large-scale deployment of solar energy requires a favorable...

404

A novel 2-D model approach for the prediction of hourly solar radiation  

Science Conference Proceedings (OSTI)

In this work, a two-dimensional (2-D) representation of the hourly solar radiation data is proposed. The model enables accurate forecasting using image prediction methods. One year solar radiation data that is acquired and collected between August 1, ...

F. Onur Hocaoglu; Ö Nezih Gerek; Mehmet Kurban

2007-06-01T23:59:59.000Z

405

Analysis of Sub-Hourly Ramping Impacts of Wind Energy and Balancing Area Size (Poster)  

DOE Green Energy (OSTI)

WindPower 2008 conference sponsored by AWEA held in Houston, TX on June 1-4 2008. This poster illustrates the data collected for an analysis of sub-hourly ramping impacts of wind energy and balancing area size.

Milligan, M.; Kirby, B.

2008-06-01T23:59:59.000Z

406

Hourly Rainfall Changes in Response to Surface Air Temperature over Eastern Contiguous China  

Science Conference Proceedings (OSTI)

In this study, late-summer rainfall over eastern contiguous China is classified according to hourly intensity and the changes of moderate, intense, and extreme precipitation in response to variation of surface air temperature are analyzed. The e-...

Rucong Yu; Jian Li

2012-10-01T23:59:59.000Z

407

6-Hour to 1-Year Variance of Five Global Precipitation Sets  

Science Conference Proceedings (OSTI)

Three-hourly time series of precipitation from three high-resolution precipitation products [Tropical Rainfall Measuring Mission (TRMM) algorithm 3B-42, the Climate Prediction Center’s morphing method (CMORPH), and the Precipitation Estimation ...

Alex C. Ruane; John O. Roads

2007-08-01T23:59:59.000Z

408

DOE's Office of Science Awards 18 Million Hours of Supercomputing Time to  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Office of Science Awards 18 Million Hours of Supercomputing Office of Science Awards 18 Million Hours of Supercomputing Time to 15 Teams for Large-Scale Scientific Computing DOE's Office of Science Awards 18 Million Hours of Supercomputing Time to 15 Teams for Large-Scale Scientific Computing February 1, 2006 - 11:14am Addthis WASHINGTON, D.C. - Secretary of Energy Samuel W. Bodman announced today that DOE's Office of Science has awarded a total of 18.2 million hours of computing time on some of the world's most powerful supercomputers to help researchers in government labs, universities, and industry working on projects ranging from designing more efficient engines to better understanding Parkinson's disease. The allocations of computing time are made under DOE's Innovative and Novel Computational Impact on Theory and Experiment (INCITE) program, now in its

409

Solar: hourly global horizontal (GHI) and direct normal (DNI) data for  

Open Energy Info (EERE)

Sri Lanka sites from DLR Sri Lanka sites from DLR Dataset Summary Description (Abstract): Hourly time series of GHI and DNI for the years 2000, 2002 and 2003 for selected sites in Sri Lanka. The hourly data are stored in ASCII files for each station. Please read the documentation file for additional information. (Purpose): For the selected sites, the hourly time series can be used for the simulation of Photovoltaic (PV)-systems or Concentrating Solar Power (CSP)-systems. Source DLR - Deutsches Zentrum für Luft- und Raumfahrt Date Released October 31st, 2004 (10 years ago) Date Updated November 01st, 2007 (7 years ago) Keywords DLR DNI GHI hourly data solar Sri Lanka SWERA TILT UNEP Data application/zip icon Download data (zip, 368.2 KiB) Quality Metrics Level of Review Some Review Comment

410

Solar: hourly global horizontal (GHI) and direct normal (DNI) data for  

Open Energy Info (EERE)

Ghana from DLR Ghana from DLR Dataset Summary Description (Abstract): Hourly time series of GHI and DNI for the years 2000, 2001 and 2002 for selected sites in Ghana. The hourly data are stored in ASCII files for each station. Please read the documentation file for additional information. (Purpose): For the selected sites, the hourly time series can be used for the simulation of Photovoltaic (PV)-systems or Concentrating Solar Power (CSP)-systems. Source DLR - Deutsches Zentrum für Luft- und Raumfahrt Date Released October 31st, 2004 (10 years ago) Date Updated November 01st, 2007 (7 years ago) Keywords DLR DNI Ghana GHI hourly data solar SWERA TILT TMY UNEP Data application/zip icon ghanaDLRtimeseries_103.zip (zip, 2.7 MiB) Quality Metrics Level of Review Some Review Comment

411

Solar: hourly global horizontal (GHI) and direct normal (DNI) data for  

Open Energy Info (EERE)

Bangladesh sites from DLR Bangladesh sites from DLR Dataset Summary Description (Abstract): Hourly time series of GHI and DNI for the years 2000, 2002 and 2003 for selected sites in Bangladesh. The hourly data are stored in ASCII files for each station. Please read the documentation file for additional information. (Purpose): For the selected sites, the hourly time series can be used for the simulation of Photovoltaic (PV)-systems or Concentrating Solar Power (CSP)-systems. Source DLR - Deutsches Zentrum für Luft- und Raumfahrt Date Released October 31st, 2004 (10 years ago) Date Updated November 01st, 2007 (7 years ago) Keywords Bangladesh DLR DNI GHI hourly data solar SWERA UNEP Data application/zip icon Download Data (zip, 1.2 MiB) Quality Metrics Level of Review Some Review Comment

412

Pantex celebrates three million hours without a lost time injury | National  

NLE Websites -- All DOE Office Websites (Extended Search)

three million hours without a lost time injury | National three million hours without a lost time injury | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Pantex celebrates three million hours without a ... Pantex celebrates three million hours without a lost time injury Posted By Office of Public Affairs NNSA Blog NNSA Blog

413

Determination of Semivariogram Models to Krige Hourly and Daily Solar Irradiance in Western Nebraska  

Science Conference Proceedings (OSTI)

In this paper, linear and spherical semivariogram models were determined for use in kriging hourly and daily solar irradiation for every season of the year. The data used to generate the models were from 18 weather stations in western Nebraska. ...

G. G. Merino; D. Jones; D. E. Stooksbury; K. G. Hubbard

2001-06-01T23:59:59.000Z

414

Spinning Reserve from Responsive Load  

SciTech Connect

As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host a spinning reserve test. The Tennessee Valley Authority (TVA) supplied real-time metering and monitoring expertise to record total hotel load during both normal operations and testing. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. The load drop was very rapid, essentially as fast as the 2 second metering could detect.

Kueck, John D [ORNL; Kirby, Brendan J [ORNL; Laughner, T [Tennessee Valley Authority (TVA); Morris, K [Tennessee Valley Authority (TVA)

2009-01-01T23:59:59.000Z

415

Hour-by-Hour Cost Modeling of Optimized Central Wind-Based Water Electrolysis Production - DOE Hydrogen and Fuel Cells Program FY 2012 Annual Progress Report  

NLE Websites -- All DOE Office Websites (Extended Search)

3 3 FY 2012 Annual Progress Report DOE Hydrogen and Fuel Cells Program Genevieve Saur (Primary Contact), Chris Ainscough. National Renewable Energy Laboratory (NREL) 15013 Denver West Parkway Golden, CO 80401-3305 Phone: (303) 275-3783 Email: genevieve.saur@nrel.gov DOE Manager HQ: Erika Sutherland Phone: (202) 586-3152 Email: Erika.Sutherland@ee.doe.gov Project Start Date: October 1, 2010 Project End Date: Project continuation and direction determined annually by DOE Fiscal Year (FY) 2012 Objectives Corroborate recent wind electrolysis cost studies using a * more detailed hour-by-hour analysis. Examine consequences of different system configuration * and operation for four scenarios, at 42 sites in five

416

The application of load models of electric appliances to distribution system analysis  

SciTech Connect

This paper proposes a methodology to apply the load models of key electric appliances in residential area for distribution system analysis. According to the load models, the transformer hourly loading is estimated during simulation iteration by the bus voltage and ambient temperature. A three phase load flow program is then executed to find the feeder daily profile of power consumption and system loss with the transformer hourly loading derived. Besides, the daily power consumption by each type of key appliances can also be solved. To demonstrate the effectiveness of the proposed method, a distribution feeder of Taipower system is selected for computer simulation to find the potential of energy conservation by controlling the feeder service voltage at substation. Moreover, the load model of air conditioners, which are temperature sensitive appliances, is also considered in the program to find the impact of ambient temperature change to the power consumption of residential distribution feeders. It is concluded that the load models of key electric appliances can provide a useful tool for distribution engineers to enhance the accuracy of system analysis to estimate the operation efficiency of distribution system in a more effective manner.

Chen, C.S.; Wu, T.H.; Lee, C.C.; Tzeng, Y.M. [National Sun Yat-Sen Univ., Kaohsiung (Taiwan, Province of China). Dept. of Electrical Engineering

1995-08-01T23:59:59.000Z

417

Advanced nonintrusive load monitoring system  

E-Print Network (OSTI)

There is a need for flexible, inexpensive metering technologies that can be deployed in many different monitoring scenarios. Individual loads may be expected to compute information about their power consumption. Utility ...

Wichakool, Warit, 1977-

2011-01-01T23:59:59.000Z

418

OpenEI - building load  

Open Energy Info (EERE)

are given by a location defined by the Typical Meteorological Year (TMY) for which the weather data was collected. Commercial load data is sorted by the (TMY) site as a...

419

Permanent Load Shift Control Strategies  

NLE Websites -- All DOE Office Websites (Extended Search)

of Permanent Load Shifting for HVAC and other storage assets as it relates to summer on-peak demand, how it can be dynamically and autonomously controlled, and its relationship...

420

Building load control and optimization  

E-Print Network (OSTI)

Researchers and practitioners have proposed a variety of solutions to reduce electricity consumption and curtail peak demand. This research focuses on load control by improving the operations in existing building HVAC ...

Xing, Hai-Yun Helen, 1976-

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Efficient and robust graphics recognition from historical maps  

Science Conference Proceedings (OSTI)

Historical maps contain rich cartographic information, such as road networks, but this information is "locked" in images and inaccessible to a geographic information system (GIS). Manual map digitization requires intensive user effort and cannot handle ... Keywords: color image segmentation, historical raster maps, image cleaning, road vectorization

Yao-Yi Chiang; Stefan Leyk; Craig A. Knoblock

2011-09-01T23:59:59.000Z

422

Historical Sulfur Dioxide Emissions 1850-2000: Methods and Results  

E-Print Network (OSTI)

PNNL-14537 Historical Sulfur Dioxide Emissions 1850-2000: Methods and Results S.J. Smith E;PNNL-14537 Historical Sulfur Dioxide Emissions 1850-2000: Methods and Results PNNL Research Report Joint Global Change Research Institute 8400 Baltimore Avenue College Park, Maryland 20740 #12;PNNL-14537

Hultman, Nathan E.

423

HISTORICAL SKETCH OF THE EXPLORATIONS IN THE GULF OF MEXICO  

E-Print Network (OSTI)

CHAPTER I HISTORICAL SKETCH OF THE EXPLORATIONS IN THE GULF OF MEXICO #12;Blank page retained for pagination #12;HISTORICAL SKETCH OF THE EXPLORATIONS IN THE GULF OF MEXICO By PAUL S. GALTSOFF, Fish and explorations in the Gulf of Mexico prcsented in this paper is based on published materials avail- able

424

Savannah River Site Celebrates Historic Closure of Radioactive Waste Tanks:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savannah River Site Celebrates Historic Closure of Radioactive Savannah River Site Celebrates Historic Closure of Radioactive Waste Tanks: Senior DOE Officials and South Carolina Congressional Leadership Gather to Commemorate Historic Cleanup Milestone Savannah River Site Celebrates Historic Closure of Radioactive Waste Tanks: Senior DOE Officials and South Carolina Congressional Leadership Gather to Commemorate Historic Cleanup Milestone October 1, 2012 - 12:00pm Addthis U.S. Energy Under Secretary for Nuclear Security Thomas D'Agostino, left, South Carolina Department of Health and Environmental Control Director Catherine Templeton and U.S. Sen. Lindsey Graham (R-SC) unveil a marker to commemorate the closing of waste tanks at the Savannah River Site in South Carolina. U.S. Energy Under Secretary for Nuclear Security Thomas D'Agostino, left,

425

Savannah River Site Celebrates Historic Closure of Radioactive Waste Tanks:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savannah River Site Celebrates Historic Closure of Radioactive Savannah River Site Celebrates Historic Closure of Radioactive Waste Tanks: Senior DOE Officials and South Carolina Congressional Leadership Gather to Commemorate Historic Cleanup Milestone Savannah River Site Celebrates Historic Closure of Radioactive Waste Tanks: Senior DOE Officials and South Carolina Congressional Leadership Gather to Commemorate Historic Cleanup Milestone October 1, 2012 - 12:00pm Addthis U.S. Energy Under Secretary for Nuclear Security Thomas D'Agostino, left, South Carolina Department of Health and Environmental Control Director Catherine Templeton and U.S. Sen. Lindsey Graham (R-SC) unveil a marker to commemorate the closing of waste tanks at the Savannah River Site in South Carolina. U.S. Energy Under Secretary for Nuclear Security Thomas D'Agostino, left,

426

Strengthening Our Partnerships with Historically Black Colleges and  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Partnerships with Historically Black Colleges and Partnerships with Historically Black Colleges and Universities Strengthening Our Partnerships with Historically Black Colleges and Universities January 13, 2011 - 6:06pm Addthis Strengthening Our Partnerships with Historically Black Colleges and Universities Secretary Chu Secretary Chu Former Secretary of Energy Last February, President Obama renewed the White House Initiative on Historically Black Colleges and Universities to encourage collaboration between government agencies, educational associations, philanthropic organizations, the private sector and others to increase the capacity of HBCUs to provide high-quality education to a greater number of students. The Department of Energy is committed to supporting education at HBCUs and has partnered with HBCUs on a variety of projects. As part of that

427

A new approach to estimate commercial sector end-use load shapes and energy use intensities  

SciTech Connect

We discuss the application of an end-use load shape estimation technique to develop annual energy use intensities (EUIs) and hourly end-use load shapes (LSs) for commercial buildings in the Pacific Gas and Electric Company (PG&E) service territory. Results will update inputs for the commercial sector energy and peak demand forecasting models used by PG&E and the California Energy Commission (CEC). EUIs were estimated for 11 building types, up to 10 end uses, 3 fuel types, 2 building vintages, and up to 5 climate regions. The integrated methodology consists of two major parts. The first part is the reconciliation of initial end-use load-shape estimates with measured whole-building load data to produce intermediate EUIs and load shapes, using LBL`s End-use Disaggregation Algorithm, EDA. EDA is a deterministic hourly algorithm that relies on the observed characteristics of the measured hourly whole-building electricity use and disaggregates it into major end-use components. The end-use EUIs developed through the EDA procedure represent a snap-shot of electricity use by building type and end-use for two regions of the PG&E service territory, for the year that disaggregation is performed. In the second part of the methodology, we adjust the EUIs for direct application to forecasting models based on factors such as climatic impacts on space-conditioning EUIs, fuel saturation effects, building and equipment vintage, and price impacts. Core data for the project are detailed on-site surveys for about 800 buildings, mail surveys ({approximately}6000), load research data for over 1000 accounts, and hourly weather data for five climate regions.

Akbari, H.; Eto, J.; Konopacki, S.; Afzal, A.; Heinemeier, K.; Rainer, L.

1994-08-01T23:59:59.000Z

428

Historical monthly energy review, 1973--1992  

Science Conference Proceedings (OSTI)

The Historical Monthly Energy Review (HMER) presents monthly and annual data from 1973 through 1992 on production, consumption, stocks, imports, exports, and prices of the principal energy commodities in the United States. Also included are data on international production of crude oil, consumption of petroleum products, petroleum stocks, and production of electricity from nuclear-powered facilities. This edition of the HMER extends the original HMER in several ways: (1) Four additional years of monthly data, 1989--1992, have been added. (2) This report fully replaces the earlier one; each data cell that has been revised since the original HMER is marked with an ``R`` so that changes can be quickly noted. (3) Section 1 has been expanded to include Tables 1.7--1.13, which were not available in the first HMER. (4) Tables 3.9 on propane and Table 4.3 on natural gas trade, which have been added to the MER since the release of the first HMER, are included in this edition. In addition, Table 10.4 on nuclear electricity gross generation has been reorganized to align more closely with the current presentation in the MER.

Not Available

1994-08-01T23:59:59.000Z

429

Accessibility and historic districts: design concepts and economic feasibility study for the downtown historic district of Bryan, Texas  

E-Print Network (OSTI)

This study explores the application of the Americans with Disabilities Act (ADA) to historic districts, and design concepts are proposed to bring the district as a whole into compliance with the ADA. Past studies have dealt with accessibility in individual historic properties, but none have touched upon large areas such as an entire district. It is concluded that implementing ADA requirements for an entire district through the sharing of accessible facilities is successful in terms of both cost savings to the owners of buildings and in maintaining the historicity of the area. The historic district of downtown Bryan, Texas has been chosen as a pilot project for the study. Two blocks of buildings were then chosen based on their non-compliance with the ADA, their age, and their contribution to the historicity of the district. This study concentrates on achieving a reasonable balance between a historic district's substantial compliance with the ADA while still maintaining its historic integrity and economic vitality. This is achieved by treating a historic district like a shopping center which allows concepts such as the transfer of development rights and shared facilities to be explored. The final step is an economic feasibility study, in which costs for strict compliance with the ADA of each individual structure in the district were compared to the costs for the recommended design concepts and alterations for the district as a whole.

Shamanna, Jayashree B

1994-01-01T23:59:59.000Z

430

Long-term residential load forecasting. Final report  

SciTech Connect

The main objective of this study was to isolate and evaluate the importance of various factors, many of which are household characteristics and weather conditions, that determine the demand for electricity at different times of day. A second purpose was to investigate one of the factors in detail, namely, prices, which was feasible because half of the households in the sample were subjected to time-of-day pricing. Substantial differences between the load curves of the experimental and control groups were found. Households in the experimental group significantly decreased electricity usage when its price was high, the consumption being shifted partly into the early morning hours but more heavily into the evening. The importance of certain appliances in shifting the load curve is also clearly brought out. For example, households with a dishwasher or electric heating appeared to change the timing of use of these appliances under peak-load pricing. Other appliances were also important in determining the load curve for both groups. Swimming pool pumps and air conditioning, for instance, were important determinants in the summer, whereas in the winter, electric heating and dishwashers substantially increased consumption levels.

Granger, C.W.J.; Engle, R.F.; Ramanathan, R.; Andersen, A.

1978-02-01T23:59:59.000Z

431

Load transfer coupling regression curve fitting for distribution load forecasting  

SciTech Connect

The planning of distribution facilities requires forecasts of future substation and feeder loads. Extrapolation based on a curve fit to past annual peak loads is currently the most popular manner of accomplishing this forecast. Curve fitting suffers badly from data shifts caused by switching as loads are routinely moved from one substation to another during the course of utility operations. This switching contaminates the data, reducing forecast accuracy. A new regression application reduces error due to these transfers by over an order of magnitude. A key to the usefulness of this method is that the amount of the transfer, and its direction (whether it was to or from a substation), is not a required input. The new technique, aspects of computer implementation of it, and a series of tests showing its advantage over normal multiple regression methods are given.

Willis, H.L.; Powell, R.W.

1984-05-01T23:59:59.000Z

432

Realizing load reduction functions by aperiodic switching of load groups  

SciTech Connect

This paper investigates the problem of scheduling ON/OFF switching of residential appliances under the control of a Load Management System (LMS). The scheduling process is intended to reduce the controlled appliances` power demand in accordance with a predefined load reduction profile. To solve this problem, a solution approach, based on the methodology of Pulse Width Modulation (PWM), is introduced. This approach provides a flexible mathematical basis for studying different aspects of the scheduling problem. The conventional practices in this area are shown to be special cases of the PWM technique. By applying the PWM-based technique to the scheduling problem, important classes of scheduling errors are identified and analytical expressions describing them are derived. These expressions are shown to provide sufficient information to compensate for the errors. Detailed simulations of load groups` response to switching actions are use to support conclusions of this study.

Navid-Azarbaijani, N. [McGill Univ., Montreal, Quebec (Canada). Dept. of Electrical Engineering; Banakar, M.H. [CAE Electronics Ltd., St. Laurent, Quebec (Canada)

1996-05-01T23:59:59.000Z

433

Prediction of clock time hourly global radiation from daily values over  

Open Energy Info (EERE)

Prediction of clock time hourly global radiation from daily values over Prediction of clock time hourly global radiation from daily values over Bangladesh Dataset Summary Description (Abstract): A need for predicting hourly global radiation exists for many locations particularly in Bangladesh for which measured values are not available and daily values have to be estimated from sunshine data. The CPRG model has been used to predict values of hourly Gh for Dhaka (23.770N, 90.380E), Chittagong (22.270N, 91.820E) and Bogra (24.850N, 89.370E) for = ±7.50, ±22.50, ±37.50, ±52.50, ±67.50, ±82.50 and ±97.50 i.e., for ±1/2, ±3/2, ±5/2, ±7/2, ±9/2, ±11/2, ±13/2 hours before and after solar noon and the computed values for different months are symmetrical about solar noon whereas for many months experimental data show a clear asymmetry. To obtain improved

434

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network (OSTI)

PSLF that incorporates motor  A?C, ZIP, and electronic load the fractions motors A?C, ZIP, and electronic loads.    Usethat incorporates motor  A?C, ZIP, and  electronic load 

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

435

Monthly Crustal Loading Corrections for Satellite Altimetry  

Science Conference Proceedings (OSTI)

Satellite altimeter measurements of sea surface height include a small contribution from vertical motion of the seafloor caused by crustal loading. Loading by ocean tides is routinely allowed for in altimeter data processing. Here, loading by ...

R. D. Ray; S. B. Luthcke; T. van Dam

2013-05-01T23:59:59.000Z

436

Writing a Historical Book Review Writing a historical book review can be different from a standard review, since it must be read and  

E-Print Network (OSTI)

Writing a Historical Book Review Writing a historical book review can be different from a standard a summary, a historical book review needs to be effective and analytical. The following links will assist you in the writing a book review: Writing an Historical Book Review http

Ellis, Randy

437

NOAA Awarded 2.6 Million Processor Hours at NERSC to Run Climate Change  

NLE Websites -- All DOE Office Websites (Extended Search)

NOAA Awarded 2.6 NOAA Awarded 2.6 Million Processor Hours at NERSC to Run Climate Change Models NOAA Awarded 2.6 Million Processor Hours at NERSC to Run Climate Change Models September 11, 2008 WASHINGTON, DC - The U.S. Department of Energy's (DOE) Office of Science will make available more than 10 million hours of computing time for the U.S. Commerce Department's National Oceanic and Atmospheric Administration (NOAA) to explore advanced climate change models at three of DOE's national laboratories as part of a three-year memorandum of understanding on collaborative climate research signed today by the two agencies. NOAA will work with climate change models as well as perform near real-time high-impact (non-production) weather prediction research using computing time on DOE Office of Science resources including two of the world's top

438

Oak Ridge: Approaching 4 Million Safe Work Hours | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Oak Ridge: Approaching 4 Million Safe Work Hours Oak Ridge: Approaching 4 Million Safe Work Hours Oak Ridge: Approaching 4 Million Safe Work Hours February 27, 2013 - 12:00pm Addthis Mike Tidwell performs a leak check and inspection on propane tanks Mike Tidwell performs a leak check and inspection on propane tanks Inspections ensure hoisting and rigging equipment performs correctly so employees can safely complete their tasks Inspections ensure hoisting and rigging equipment performs correctly so employees can safely complete their tasks Mike Tidwell performs a leak check and inspection on propane tanks Inspections ensure hoisting and rigging equipment performs correctly so employees can safely complete their tasks OAK RIDGE, Tenn. - Workers at URS | CH2M Oak Ridge (UCOR), the prime contractor for EM's Oak Ridge cleanup, are approaching a milestone of 4

439

On a QUEST to Save Oakland 8.4 Gigawatt Hours | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

On a QUEST to Save Oakland 8.4 Gigawatt Hours On a QUEST to Save Oakland 8.4 Gigawatt Hours On a QUEST to Save Oakland 8.4 Gigawatt Hours August 13, 2010 - 3:38pm Addthis Lorelei Laird Writer, Energy Empowers Derrick Rebello wants to make the downtown corridor of Oakland, California, one of the greenest in the nation. Through the new Downtown Oakland Targeted Measure Saturation Project, he and his company, Quantum Energy Services and Technologies (QUEST), are targeting the city's 120-block business district to make as many buildings as possible highly energy efficient. "The goal is to really leave no stone unturned," said Rebello, president of QUEST. "We are trying to achieve 80 percent participation. And of those participating buildings, we are focusing on getting a 20 percent reduction

440

Developing hourly weather data for locations having only daily weather data  

Science Conference Proceedings (OSTI)

A methodology was developed to modify an hourly TMY weather tape to be representative of a location for which only average daily weather parameters were avilable. Typical hourly and daily variations in solar flux, and other parameters, were needed to properly exercise a computer model to predict the transient performance of a solar controlled greenhouse being designed for Riyadh, Saudi Arabia. The starting point was a TMY tape for Yuma, Arizona, since the design temperatures for summer and winter are nearly identical for Yuma and Riyadh. After comparing six of the most important weather variables, the hourly values on the Yuma tape were individually adjusted to give the same overall daily average conditions as existed in the long-term Riyadh data. Finally, a statistical analysis was used to confirm quantitatively that the daily variations between the long term average values for Riyadh and the modified TMY weather tape for Yuma matched satisfactorily.

Talbert, S.G.; Herold, K.E.; Jakob, F.E.; Lundstrom, D.K.

1983-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Solar: hourly global horizontal (GHI) and direct normal (DNI) data for  

Open Energy Info (EERE)

China sites from DLR China sites from DLR Dataset Summary Description (Abstract): Hourly time series of GHI and DNI for the years 2000, 2002 and 2003 for selected sites in China. The hourly data are stored in ASCII files for each station. Please read the documentation file for additional information. (Purpose): For the selected sites, the hourly time series can be used for the simulation of Photovoltaic (PV)-systems or Concentrating Solar Power (CSP)-systems. Source DLR - Deutsches Zentrum für Luft- und Raumfahrt Date Released October 31st, 2004 (10 years ago) Date Updated November 01st, 2007 (7 years ago) Keywords China DLR DNI GEF GHI solar SWERA UNEP Data application/zip icon Download Data (zip, 953.6 KiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage

442

Sub-Hour Solar Data for Power System Modeling From Static Spatial Variability Analysis: Preprint  

Science Conference Proceedings (OSTI)

High penetration renewable integration studies need high quality solar power data with spatial-temporal correlations that are representative of a real system. This paper will summarize the research relating sequential point-source sub-hour global horizontal irradiance (GHI) values to static, spatially distributed GHI values. This research led to the development of an algorithm for generating coherent sub-hour datasets that span distances ranging from 10 km to 4,000 km. The algorithm, in brief, generates synthetic GHI values at an interval of one-minute, for a specific location, using SUNY/Clean Power Research, satellite-derived, hourly irradiance values for the nearest grid cell to that location and grid cells within 40 km.

Hummon, M.; Ibanez, E.; Brinkman, G.; Lew, D.

2012-12-01T23:59:59.000Z

443

Building Energy Software Tools Directory: Load Express  

NLE Websites -- All DOE Office Websites (Extended Search)

graphical interface makes Load Express a powerful engineering tool with a very short learning curve. The "rookie" or experienced user can quickly and accurately perform load...

444

Self-aligning biaxial load frame  

DOE Patents (OSTI)

An self-aligning biaxial loading apparatus for use in testing the strength of specimens while maintaining a constant specimen centroid during the loading operation. The self-aligning biaxial loading apparatus consists of a load frame and two load assemblies for imparting two independent perpendicular forces upon a test specimen. The constant test specimen centroid is maintained by providing elements for linear motion of the load frame relative to a fixed cross head, and by alignment and linear motion elements of one load assembly relative to the load frame. 3 figures.

Ward, M.B.; Epstein, J.S.; Lloyd, W.R.

1994-01-18T23:59:59.000Z

445

Decentralized customerlevel under frequency load shedding in...  

Open Energy Info (EERE)

enables the management of large groups of distributed loads under a single innovative control schemes to use the flexibility of electrical loads for power system purposes....

446

Amp-hour counting charge control for photovoltaic hybrid power systems  

SciTech Connect

An amp-hour counting battery charge control algorithm has been defined and tested using the Digital Solar Technologies MPR-9400 microprocessor based photovoltaic hybrid charge controller. This work included extensive laboratory and field testing of the charge algorithm on vented lead-antimony and valve regulated lead-acid batteries. The test results have shown that with proper setup amp-hour counting charge control is more effective than conventional voltage regulated sub-array shedding in returning the lead-acid battery to a high state of charge.

Hund, T.D. [Sandia National Labs., Albuquerque, NM (United States); Thompson, B. [Biri Systems, Ithaca, NY (United States)

1997-10-01T23:59:59.000Z

447

The Base Load Fallacy and other Fallacies disseminated by Renewable Energy Deniers  

E-Print Network (OSTI)

Abstract: The Base-Load Fallacy is the incorrect notion that renewable energy cannot supply base-load (24-hour) electric power. Alternatives to base-load coal power can be provided by efficient energy use, solar hot water, bioenergy, large-scale wind power, solar thermal electricity with thermal storage, and geothermal, with gas power playing a transitional role. In particular, large-scale wind power from geographically distributed sites is partially reliable and can be made more so by installing a little additional low-cost peak-load back-up from gas turbines. Other fallacies are refuted concisely in the appendix. 1 Opponents of renewable energy, from the coal and nuclear industries and from NIMBY (Not In My Backyard) groups, are disseminating the Base-Load Fallacy, that is, the fallacy that renewable energy cannot provide base-load (24-hour) power to substitute for coal-fired electricity. In Australia, even Government Ministers and some journalists are propagating this conventional ‘wisdom’, although it is false. This fallacy is the principal weapon of renewable energy deniers. Other fallacies are discussed briefly in the appendix. The political implications are that, if these fallacies become widely believed, renewable energy would always have to remain a niche market, rather than achieve its true potential of becoming a

Dr Mark Diesendorf

2010-01-01T23:59:59.000Z

448

Method for loading resin beds  

DOE Patents (OSTI)

An improved method of preparing nuclear reactor fuel by carbonizing a uranium loaded cation exchange resin provided by contacting a H.sup.+ loaded resin with a uranyl nitrate solution deficient in nitrate, comprises providing the nitrate deficient solution by a method comprising the steps of reacting in a reaction zone maintained between about 145.degree.-200.degree. C, a first aqueous component comprising a uranyl nitrate solution having a boiling point of at least 145.degree. C with a second aqueous component to provide a gaseous phase containing HNO.sub.3 and a reaction product comprising an aqueous uranyl nitrate solution deficient in nitrate.

Notz, Karl J. (Oak Ridge, TN); Rainey, Robert H. (Knoxville, TN); Greene, Charles W. (Knoxville, TN); Shockley, William E. (Oak Ridge, TN)

1978-01-01T23:59:59.000Z

449

An hourly-based performance comparison of an integrated micro-structural perforated shading screen with standard shading systems  

E-Print Network (OSTI)

during summer and solar heating gains during the winter. Theconsider heating by increasing solar gains, cooling byand cooling loads. Heating loads excluded solar gains and

Appelfeld, David

2013-01-01T23:59:59.000Z

450

Six- and three-hourly meteorological observations from 223 USSR stations  

SciTech Connect

This document describes a database containing 6- and 3-hourly meteorological observations from a 223-station network of the former Soviet Union. These data have been made available through cooperation between the two principal climate data centers of the United States and Russia: the National Climatic Data Center (NCDC), in Asheville, North Carolina, and the All-Russian Research Institute of Hydrometeorological Information -- World Data Centre (RIHMI-WDC) in Obninsk. Station records consist of 6- and 3-hourly observations of some 24 meteorological variables including temperature, weather type, precipitation amount, cloud amount and type, sea level pressure, relative humidity, and wind direction and speed. The 6-hourly observations extend from 1936 to 1965; the 3-hourly observations extend from 1966 through the mid-1980s (1983, 1984, 1985, or 1986; depending on the station). These data have undergone extensive quality assurance checks by RIHMI-WDC, NCDC, and the Carbon Dioxide Information Analysis Center (CDIAC). The database represents a wealth of meteorological information for a large and climatologically important portion of the earth`s land area, and should prove extremely useful for a wide variety of regional climate change studies. These data are available free of charge as a numeric data package (NDP) from CDIAC. The NDP consists of this document and 40 data files that are available via the Internet or on 8mm tape. The total size of the database is {approximately}2.6 gigabytes.

Razuvaev, V.N.; Apasova, E.B.; Martuganov, R.A. [All-Russian Research Inst. of Hydrometeorologicl Information, Obninsk (Russia). World Data Centre; Kaiser, D.P. [Oak Ridge National Lab., TN (United States)

1995-04-01T23:59:59.000Z

451

NETL: News Release - DOE Awards Local Researcher with 3 Million Hours on  

NLE Websites -- All DOE Office Websites (Extended Search)

8, 2008 8, 2008 DOE Awards Local Researcher with 3 Million Hours on Premier Supercomputer Morgantown, W.Va.-The U.S. Department of Energy's (DOE) Office of Science announced today that a scientist at DOE's National Energy Technology Laboratory (NETL) has been awarded 3 million hours of processor time to conduct advanced research on fossil fuel power plants on one of the world's most powerful supercomputers. http://energy.gov/news/5849.htm The Office of Science awarded the supercomputer hours to Madhava Syamlal, a scientist at NETL, as one of 55 nationwide recipients who received a total of 265 million processor hours. Syamlal, along with his team of co-investigators, will use the powerful Cray XT4 supercomputer at ORNL to vastly increase the speed of coal gasifier simulations to aid in the design and optimization of the power plants. His team is composed of Thomas O'Brien (NETL), Chris Guenther (NETL), Sreekanth Pannala (ORNL), Ramanan Sankaran (ORNL), and Aytekin Gel (Aeolus Research Inc.).

452

Thirty states sign ITER nuclear fusion plant deal 1 hour, 28 minutes ago  

E-Print Network (OSTI)

than 30 countries signed a deal on Tuesday to build the world's most advanced nuclear fusion reactor nuclear reactors, but critics argue it could be at least 50 years before a commercially viable reactorThirty states sign ITER nuclear fusion plant deal 1 hour, 28 minutes ago Representatives of more

453

NREL RSF Weather Data 2011 A csv containing hourly weather data...  

Open Energy Info (EERE)

NREL RSF Weather Data 2011 A csv containing hourly weather data at NREL's Research and Support Facility (RSF) for 2011. 2013-02-12T18:36:26Z 2013-02-12T18:36:26Z I am submitting...

454

Predicting Future Hourly Residential Electrical Consumption: A Machine Learning Case Study  

E-Print Network (OSTI)

(e.g., HVAC) for a specific building, optimizing control systems and strategies for a buildingPredicting Future Hourly Residential Electrical Consumption: A Machine Learning Case Study Richard building energy modeling suffers from several factors, in- cluding the large number of inputs required

Tennessee, University of

455

Sams Teach Yourself Paint Shop Pro 6 in 24 Hours, 1st edition  

Science Conference Proceedings (OSTI)

From the Publisher:This easily accessible tutorial uses a friendly, conversational approach to teach you the basics of Paint Shop Pro 6. With its careful, step-by-step approach, Sams Teach Yourself Paint Shop Pro 6 in 24 Hours makes it easy even for ...

T. Michael Clark; Michael Clark / Kris Tufto

1999-11-01T23:59:59.000Z

456

REDCap 102 Training Session This two-hour session presented by Heather Kim  

E-Print Network (OSTI)

at Vanderbilt. This version of REDCap is main- tained by the UIC Design and Analysis Core, and is offeredREDCap 102 Training Session This two-hour session presented by Heather Kim will explore some Capture) is a secure, web- based application for building and managing online databases for the collection

Illinois at Chicago, University of

457

REDCap 102 Training Session This two-hour session presented by John O'Keefe  

E-Print Network (OSTI)

REDCap team at Vanderbilt. This version of REDCap is main- tained by the UIC Design and Analysis CoreREDCap 102 Training Session This two-hour session presented by John O'Keefe will explore some Data Capture) is a secure, web- based application for building and managing online databases

Illinois at Chicago, University of

458

Climatology of Heavy Rain Events in the United States from Hourly Precipitation Observations  

Science Conference Proceedings (OSTI)

Flash flooding is frequently associated with heavy precipitation (defined here as ?1 in. h?1) occurring over a short period of time. To begin a study of flash flood–producing rain events, the Hourly Precipitation Dataset (HPD) is used to develop ...

Harold E. Brooks; David J. Stensrud

2000-04-01T23:59:59.000Z

459

From the Big Bang to the Higgs Boson in Less Than an Hour  

E-Print Network (OSTI)

From the Big Bang to the Higgs Boson in Less Than an Hour Jeffrey D H Higgs boson Gauge bosons (force field quanta) Higgs boson and vacuum expectation value Strong) photon Z boson W bosons H Higgs boson Gauge bosons (force field quanta) Higgs boson and vacuum

Fygenson, Deborah Kuchnir

460

From the Big Bang to the Higgs Boson in Less Than an Hour  

E-Print Network (OSTI)

From the Big Bang to the Higgs Boson in Less Than an Hour Jeffrey D neutrino Z0 W + W -g gluon (8) photon Z boson W bosons Quarks Leptons H Higgs boson Gauge bosons (force field quanta) Higgs boson and vacuum expectation value Strong force EM force Weak force #12;Par7cles

Fygenson, Deborah Kuchnir

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Fuel Cell Stacks Still Going Strong After 5,000 Hours  

Energy.gov (U.S. Department of Energy (DOE))

Two fuel cell stacks developed by FuelCell Energy in partnership with Versa Power Systems achieved 5,000 hours of service in February, meeting a goal of the U.S. Department of Energy's Solid State Energy Conversion Alliance.

462

EMERGENCY CONTACTS for DOWNER LAB Contact Phone After Hours Purpose/Additional Info  

E-Print Network (OSTI)

EMERGENCY CONTACTS for DOWNER LAB Contact Phone After Hours Purpose/Additional Info UT Police.utexas.edu/facilities/services for further information and non-emergency service request forms) Environmental Health & Safety 471-3511 911 emergencies, call 911 or go to a local hospital emergency room. (see healthyhorns.utexas.edu/emergencies

Shvets, Gennady

463

Development of global hourly 0.5-degree land surface air temperature datasets  

Science Conference Proceedings (OSTI)

Land surface air temperature (SAT) is one of the most important variables in weather and climate studies, and its diurnal cycle and day-to-day variation are also needed for a variety of applications. Global long-term hourly SAT observational data, ...

Aihui Wang; Xubin Zeng

464

Development of Global Hourly 0.5° Land Surface Air Temperature Datasets  

Science Conference Proceedings (OSTI)

Land surface air temperature (SAT) is one of the most important variables in weather and climate studies, and its diurnal cycle is also needed for a variety of applications. Global long-term hourly SAT observational data, however, do not exist. ...

Aihui Wang; Xubin Zeng

2013-10-01T23:59:59.000Z

465

PRB rail loadings shatter record  

Science Conference Proceedings (OSTI)

Rail transport of coal in the Powder River Basin has expanded, with a record 2,197 trains loaded in a month. Arch Coal's Thunder basin mining complex has expanded by literally bridging the joint line railway. The dry fork mine has also celebrated its safety achievements. 4 photos.

Buchsbaum, L.

2008-09-15T23:59:59.000Z

466

Automatic Electric Load Identification in  

E-Print Network (OSTI)

Abstract — A microgrid is the power system of choice for the electrification of rural areas in developing countries. It should be able to adapt to changing load situations without the need for specialists to change the configuration of the microgrid controller. This paper proposes a self-configuring microgrid management system that is able to adjust both generation and demand of the system, so that also in case of growing electricity demand the grid can still be operable by disconnecting unessential loads. A crucial task for the microgrid controller is to automatically identify the connected loads on the basis of their consumption behaviors. For this, a template-matching algorithm is proposed that is based on Dynamic Time Warping, which is primarily used in speech recognition. It has been found that for load profile analysis, simple signal features such as the number of rising edges or the aggregated energy consumption in a given time window is sufficient to describe the signal. In contrast to speech recognition, frequency domain analysis is not necessary.

Self-configuring Microgrids; Friederich Kupzog; Tehseen Zia; Adeel Abbas Zaidi

2009-01-01T23:59:59.000Z

467

Puget Sound Area Electric Reliability Plan. Appendix D, Conservation, Load Management and Fuel Switching Analysis : Draft Environmental Impact Statement.  

SciTech Connect

Various conservation, load management, and fuel switching programs were considered as ways to reduce or shift system peak load. These programs operate at the end-use level, such as residential water heat. Figure D-1a shows what electricity consumption for water heat looks like on normal and extreme peak days. Load management programs, such as water heat control, are designed to reduce electricity consumption at the time of system peak. On the coldest day in average winter, system load peaks near 8:00 a.m. In a winter with extremely cold weather, electricity consumption increases fr all hours, and the system peak shifts to later in the morning. System load shapes in the Puget Sound area are shown in Figure D-1b for a normal winter peak day (February 2, 1988) and extreme peak day (February 3, 1989). Peak savings from any program are calculated to be the reduction in loads on the entire system at the hour of system peak. Peak savings for all programs are measured at 8:00 a.m. on a normal peak day and 9:00 a.m. on an extreme peak day. On extremely cold day, some water heat load shifts to much later in the morning, with less load available for shedding at the time of system peak. Models of hourly end-use consumption were constructed to simulate the impact of conservation, land management, and fuel switching programs on electricity consumption. Javelin, a time-series simulating package for personal computers, was chosen for the hourly analysis. Both a base case and a program case were simulated. 15 figs., 7 tabs.

United States. Bonneville Power Administration.

1991-09-01T23:59:59.000Z

468

End-Use Load and Consumer Assessment Program: Analysis of residential refrigerator/freezer performance  

SciTech Connect

The Bonneville Power Administration (Bonneville) is conducting a large end-use data acquisition program in an effort to understand how energy is utilized in buildings with permanent electric space heating equipment in the Pacific Northwest. The initial portion of effort, known as the End-Use Load and Consumer Assessment Program (ELCAP), was conducted for Bonneville by the Pacific Northwest Laboratory (PNL). The collection of detailed end-use data provided an opportunity to analyze the amount of energy consumed by both refrigerators and separate freezers units located in residential buildings. By obtaining this information, the uncertainty of long- term regional end-use forecasting can be improved and potential utility marketing programs for new appliances with a reduced overall energy demand can be identified. It was found that standby loads derived from hourly averages between 4 a.m. and 5 a.m. reflected the minimum consumption needed to maintain interior refrigerator temperatures at a steady-state condition. Next, an average 24-hour consumption that included cooling loads from door openings and cooling food items was also determined. Later, analyses were conducted to develop a model capable of predicting refrigerator standby loads and 24-hour consumption for comparison with national refrigerator label ratings. Data for 140 residential sites with a refrigeration end-use were screened to develop a sample of 119 residences with pure refrigeration for use in this analysis. To identify those refrigerators that were considered to be pure (having no other devices present on the circuit) in terms of their end-use classification, the screening procedure used a statistical clustering technique that was based on standby loads with 24-hour consumption. 5 refs., 18 figs., 4 tabs.

Ross, B.A.

1991-09-01T23:59:59.000Z

469

Permanent Peak Load Shift Product Deployment for Smart Grid Integration and Operation  

Science Conference Proceedings (OSTI)

This project tested and evaluated an innovative energy storage technology that provides permanent peak load shifting using electro-thermal energy storage in combination with commercial unitary rooftop air conditioning systems. Four Ice Bear 30 units were deployed at a Staples facility to store an estimated 32 kWh each of energy in 10 off-peak hours and reduce an estimated 5 kW of site energy demand for an on-peak six-hour period. The Ice Bear units are monitored and controlled with a smart grid ...

2012-11-14T23:59:59.000Z

470

Historic Railroad Building Goes Net Zero | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Historic Railroad Building Goes Net Zero Historic Railroad Building Goes Net Zero Historic Railroad Building Goes Net Zero July 29, 2010 - 5:16pm Addthis Richmond and Chesapeake Bay Railway Car Barn will serve as an example of green building in the community. | Photo by Julie Wescott Weissend Richmond and Chesapeake Bay Railway Car Barn will serve as an example of green building in the community. | Photo by Julie Wescott Weissend Lindsay Gsell What are the key facts? Former electric railroad barn uses less energy than it generates. Historic building has solar and geothermal energy systems. Construction company receiving federal and state tax credits. Dovetail Construction Company saw a unique challenge - and opportunity - with a neglected 1880s-era Richmond and Chesapeake Bay Railway Car Barn.

471

SAVANNAH RIVER SITE COLD WAR HISTORIC PROPERTY DOCUMENTATION  

NLE Websites -- All DOE Office Websites (Extended Search)

WAR HISTORIC PROPERTY DOCUMENTATION WAR HISTORIC PROPERTY DOCUMENTATION NARRATIVE AND PHOTOGRAPHY CMX AND TNX SAVANNAH RIVER'S PILOT PLANTS Aiken County, South Carolina SAVANNAH RIVER SITE COLD WAR HISTORIC PROPERTY DOCUMENTATION CMX AND TNX CMX AND TNX SA SA V V ANNAH RIVER'S ANNAH RIVER'S PILOT PLANTS PILOT PLANTS Aiken County, South Carolina NARRATIVE AND PHOTOGRAPHY ii ABSTRACT This documentation was prepared in accordance with a Memorandum of Agreement (MOA) signed by the Department of Energy-Savannah River (DOE-SR) and the South Carolina Historic Preservation Office (SHPO) dated February 27, 2003, as well as the Consolidated MOA of August 2004. The MOA stipulated a thematic study and photographic documentation of 679-T and 678-T, known respectively as the CMX and TNX buildings. Initially, this area was called the CMX-TNX

472

A Solar Decathlon Entry for Historic Norfolk | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

A Solar Decathlon Entry for Historic Norfolk A Solar Decathlon Entry for Historic Norfolk A Solar Decathlon Entry for Historic Norfolk August 11, 2011 - 3:22pm Addthis Erin R. Pierce Erin R. Pierce Digital Communications Specialist, Office of Public Affairs How can I participate? The next Solar Decathlon will be held Sept. 23-Oct. 2, 2011, at the National Mall's West Potomac Park in Washington, D.C. Come check it out! In honor of the U.S Department of Energy's Solar Decathlon -- which challenges 20 collegiate teams to design, build, and operate solar-powered houses that are cost-effective, energy-efficient, and attractive -- we are profiling each of the 20 teams participating in the competition. It's a tale of two universities with a vision for one historic city. Students from both Hampton and Old Dominion universities have joined forces

473

Historical Federal Government Energy Use Data Available | Data.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Historical Federal Government Energy Use Data Available Historical Federal Government Energy Use Data Available Energy Data Apps Maps Challenges Resources Blogs Let's Talk Energy Beta You are here Data.gov » Communities » Energy » Blogs Historical Federal Government Energy Use Data Available Submitted by Chris Tremper on Mon, 10/31/2011 - 1:54am Log in to vote 10 Federal Energy Management Program logo The Department of Energy's Federal Energy Management Program (FEMP) is pleased to release historical energy use and cost data for the Federal Government for the fiscal years 1975 through 2007. Data for later years will be released in the near future, but for now, are considered preliminary as the method for collecting the data changed last year to accommodate the 2008 baseline of the Federal greenhouse gas goals under Executive Order 13514.

474

Students, Faculty from Historically Black Colleges and Universities Share  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Students, Faculty from Historically Black Colleges and Universities Students, Faculty from Historically Black Colleges and Universities Share Research with EM Laboratory in Successful Exchange Students, Faculty from Historically Black Colleges and Universities Share Research with EM Laboratory in Successful Exchange February 5, 2013 - 12:00pm Addthis South Carolina State University students William Dumpson, left, and Alejandra Chirino, center, talk with Savannah River National Laboratory Director Dr. Terry Michalske at a recent research exchange involving the laboratory and seven historically black colleges and universities. South Carolina State University students William Dumpson, left, and Alejandra Chirino, center, talk with Savannah River National Laboratory Director Dr. Terry Michalske at a recent research exchange involving the

475

DOE Applauds Opening of Historic Disposal Facility | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE Applauds Opening of Historic Disposal Facility DOE Applauds Opening of Historic Disposal Facility DOE Applauds Opening of Historic Disposal Facility June 6, 2013 - 12:00pm Addthis The Waste Control Specialists Federal Waste Disposal Facility in Andrews, Texas. The Waste Control Specialists Federal Waste Disposal Facility in Andrews, Texas. ANDREWS, Texas - DOE officials participated in an event today to celebrate the opening of the first commercial disposal facility of its kind. EM Senior Advisor Dave Huizenga and several other federal, state and local officials attended the event at Waste Control Specialists (WCS) in Andrews and witnessed the first container being placed in the new state-of-the-art facility. WCS is a waste processing and disposal company. "I am proud to be here today to celebrate this historic event. We

476

Portland Company Weatherizes, Preserves Historic Home | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Company Weatherizes, Preserves Historic Home Company Weatherizes, Preserves Historic Home Portland Company Weatherizes, Preserves Historic Home June 9, 2010 - 2:07pm Addthis Insulation is blown into the home of Roy and Kim Fox in Portland, Ore. EcoTech modified its equipment to avoid damaging the home, which was built in 1884. | Photo courtesy of Roy Fox | Insulation is blown into the home of Roy and Kim Fox in Portland, Ore. EcoTech modified its equipment to avoid damaging the home, which was built in 1884. | Photo courtesy of Roy Fox | Paul Lester Communications Specialist for the Office of Energy Efficiency and Renewable Energy "Lots of people come to see our house but these people were here to see weatherization." Roy Fox, historic homeowner On most days, visitors traipsing up the doorsteps of Roy and Kim Fox's

477

TENNESSEE HISTORICAL COMMISSION DEPARTMENT OF ENVIRONMENT AND CONSERVATION  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

June 30, 20 II June 30, 20 II TENNESSEE HISTORICAL COMMISSION DEPARTMENT OF ENVIRONMENT AND CONSERVATION 2941 LEBANON ROAD NASHVILLE, TN 37243-0442 Ms. Susanna Sutherland (615) 532·1550 City of Knoxville Posl Office Box 1631 Knoxville, Tennessee, 37901 RE: DOE, SOLAR ASSISTED CHARGING STAnONS, KNOXVILLE, KNOX COUNTY Dear Ms. Sutherland: In response to your request, received on Tuesday, June 28, 2011, we have reviewed the documents you submitted regarding your proposed undertaking. Our review of and comment on your proposed undertaking are among the requirements of Section 106 of the National Historic Preservation Act. This Act requires federal agencies or applicant for federal assistance to consult with the appropriate State Historic Preservation Office before tbey carry out their proposed undertakings. The Advisory Council on Historic

478

The 1993 Midwest Extreme Precipitation in Historical and Probabilistic Perspective  

Science Conference Proceedings (OSTI)

Extreme rainfall amounts that resulted in severe flooding during the spring and summer of 1993 along the Missouri and Mississippi Rivers are examined from a historical and probabilistic viewpoint. Long-term average precipitation amounts and the ...

Nathaniel B. Guttman; J. R. M. Hosking; James R. Wallis

1994-10-01T23:59:59.000Z

479

Historic Railroad Building Goes Net Zero | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Historic Railroad Building Goes Net Zero Historic Railroad Building Goes Net Zero Historic Railroad Building Goes Net Zero July 29, 2010 - 5:16pm Addthis Richmond and Chesapeake Bay Railway Car Barn will serve as an example of green building in the community. | Photo by Julie Wescott Weissend Richmond and Chesapeake Bay Railway Car Barn will serve as an example of green building in the community. | Photo by Julie Wescott Weissend Lindsay Gsell What are the key facts? Former electric railroad barn uses less energy than it generates. Historic building has solar and geothermal energy systems. Construction company receiving federal and state tax credits. Dovetail Construction Company saw a unique challenge - and opportunity - with a neglected 1880s-era Richmond and Chesapeake Bay Railway Car Barn.

480

A Solar Decathlon Entry for Historic Norfolk | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

A Solar Decathlon Entry for Historic Norfolk A Solar Decathlon Entry for Historic Norfolk A Solar Decathlon Entry for Historic Norfolk August 11, 2011 - 3:22pm Addthis Erin R. Pierce Erin R. Pierce Digital Communications Specialist, Office of Public Affairs How can I participate? The next Solar Decathlon will be held Sept. 23-Oct. 2, 2011, at the National Mall's West Potomac Park in Washington, D.C. Come check it out! In honor of the U.S Department of Energy's Solar Decathlon -- which challenges 20 collegiate teams to design, build, and operate solar-powered houses that are cost-effective, energy-efficient, and attractive -- we are profiling each of the 20 teams participating in the competition. It's a tale of two universities with a vision for one historic city. Students from both Hampton and Old Dominion universities have joined forces

Note: This page contains sample records for the topic "historical hourly load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Students, Faculty from Historically Black Colleges and Universities Share  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Students, Faculty from Historically Black Colleges and Universities Students, Faculty from Historically Black Colleges and Universities Share Research with EM Laboratory in Successful Exchange Students, Faculty from Historically Black Colleges and Universities Share Research with EM Laboratory in Successful Exchange February 5, 2013 - 12:00pm Addthis South Carolina State University students William Dumpson, left, and Alejandra Chirino, center, talk with Savannah River National Laboratory Director Dr. Terry Michalske at a recent research exchange involving the laboratory and seven historically black colleges and universities. South Carolina State University students William Dumpson, left, and Alejandra Chirino, center, talk with Savannah River National Laboratory Director Dr. Terry Michalske at a recent research exchange involving the

482

The Global Historical Climatology Network: Long-Term Monthly Temperature,  

NLE Websites -- All DOE Office Websites (Extended Search)

The Global Historical Climatology Network: Long-Term Monthly Temperature, The Global Historical Climatology Network: Long-Term Monthly Temperature, Precipitation, Sea Level Pressure, and Station Pressure Data (1992) (NDP-041) DOI: 10.3334/CDIAC/cli.ndp041 data Data PDF PDF File graphics NDP-041 Temperature Stations graphics NDP-041 Precipitation Stations Please note: the latest version of the Global Historical Climatology Network (GHCN) is available directly from NOAA's National Climatic Data Center. Investigators R. S. Vose, R. L. Schmoyer, P. M. Steurer, T. C. Peterson, R. Heim, T. R. Karl, and J. K. Eischeid This NDP contains monthly temperature, precipitation, sea-level pressure, and station-pressure data for thousands of meteorological stations worldwide. The database was compiled from pre-existing national, regional, and global collections of data as part of the Global Historical Climatology

483

Historical Information on the Transportation External Coordination Working  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Historical Information on the Transportation External Coordination Historical Information on the Transportation External Coordination Working Group (TEC) Historical Information on the Transportation External Coordination Working Group (TEC) Historical Information on the Transportation External Coordination Working Group (TEC) TEC was formed in 1992 to improve coordination between the U.S. Department of Energy (DOE) and external groups interested in the Department's transportation activities. TEC was co-chaired by DOE's Office of Civilian Radioactive Waste Management and the Office of Environmental Management. Going the Distance "Going the Distance? The Safe Transport of Spent Nuclear Fuel and High-Level Radioactive Waste in the United States" available for free download from the National Academic Press Resources

484

DOE Applauds Opening of Historic Disposal Facility | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Applauds Opening of Historic Disposal Facility Applauds Opening of Historic Disposal Facility DOE Applauds Opening of Historic Disposal Facility June 6, 2013 - 12:00pm Addthis The Waste Control Specialists Federal Waste Disposal Facility in Andrews, Texas. The Waste Control Specialists Federal Waste Disposal Facility in Andrews, Texas. ANDREWS, Texas - DOE officials participated in an event today to celebrate the opening of the first commercial disposal facility of its kind. EM Senior Advisor Dave Huizenga and several other federal, state and local officials attended the event at Waste Control Specialists (WCS) in Andrews and witnessed the first container being placed in the new state-of-the-art facility. WCS is a waste processing and disposal company. "I am proud to be here today to celebrate this historic event. We

485

A Historic Commitment to Research and Education | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

A Historic Commitment to Research and Education A Historic Commitment to Research and Education A Historic Commitment to Research and Education April 27, 2009 - 12:00am Addthis WASHINGTON, DC -- In a speech to the National Academy of Sciences, President Obama outlined a bold commitment to basic and applied research, innovation and education. The White House fact sheet is below. Read more information about the 46 Energy Frontier Research Centers. View the Funding Opportunity Announcement for ARPA-E. THE WHITE HOUSE Office of the Press Secretary FACT SHEET: A HISTORIC COMMITMENT TO RESEARCH AND EDUCATION Today, President Obama will speak before the Annual Meeting of the National Academy of Sciences, and discuss his plans to reinvigorate the American scientific enterprise through a bold commitment to basic and applied

486

Hermetically sealed encasements for historic document display and preservation  

E-Print Network (OSTI)

The goal of this thesis was to develop designs and methods for the preservation and display of historic documents. The results were applied via the design, manufacture, and installation of five hermetic display encasements ...

Durand, Keith (Keith V.)

2011-01-01T23:59:59.000Z

487

An Introduction to Some Historical Governmental Weather Records of China  

Science Conference Proceedings (OSTI)

Some historical weather records of China in the governmental archives are discussed. The records in the pre-Qing period (before 1636) am briefly summarized and their use for the reconstruction of past climate is assessed. The more-elaborate ...

Pao K. Wang; De'er Zhang

1988-07-01T23:59:59.000Z

488

Distribution of Landscape Types in the Global Historical Climatology Network  

Science Conference Proceedings (OSTI)

The Global Historical Climate Network version 2 (GHCNv.2) surface temperature dataset is widely used for reconstructions such as the global average surface temperature (GAST) anomaly. Because land use and land cover (LULC) affect temperatures, it ...

Laure M. Montandon; Souleymane Fall; Roger A. Pielke Sr.; Dev Niyogi

2011-02-01T23:59:59.000Z

489

Observations from Space and Thermal Convection: A Historical Perspective  

Science Conference Proceedings (OSTI)

An abbreviated historical account of the evolution of the satellite meteorology program is presented. Emphasis is placed on the importance of the satellite and its space platform for observing and studying atmospheric convection. Particular ...

Ernest M. Agee

1984-09-01T23:59:59.000Z

490

Historical Atmospheric Transmission Changes and Changes in Midwestern Air Pollution  

Science Conference Proceedings (OSTI)

Measurements of haze, smoke, dust, and visibility in the midwest available from 1901 to 1980 reveal sizable temporal fluctuations. These appear useful as surrogates of air pollutants not measured before 1950. Their historical record reflects both ...

Stanley A. Changnon

1987-05-01T23:59:59.000Z

491

The 1980 Summer Heat Wave and Drought in Historical Perspective  

Science Conference Proceedings (OSTI)

Economic losses during the hot, dry summer of 1980 were estimated at $16 billion. Despite these substantial economic losses, analyses of historical (1895–1980) monthly temperature and precipitation data across the 48 contiguous United States ...

Thomas R. Karl; Robert G. Quayle

1981-10-01T23:59:59.000Z

492

Contemporary and historical classification of crop types in Arizona  

Science Conference Proceedings (OSTI)

This research compares three different classification algorithms for mapping crops in Pinal County, Arizona, using both present and historical image data. The study area lacked past crop maps, and farmers were dealing with the risk of evolution of resistance ...

KyleA. Hartfield, StuartE. Marsh, ChristaD. Kirk, Yves Carrière

2013-09-01T23:59:59.000Z

493

The Use of Spanish Historical Archives to Reconstruct Climate Variability  

Science Conference Proceedings (OSTI)

Spanish historical archives contain a vast store of information about Spain and its former colonies in America and Asia. Some searches for climate-related information within these archives have been undertaken recently, but they have been by no ...

Ricardo García Herrera; Rolando R. García; M. Rosario Prieto; Emiliano Hernández; Luis Gimeno; Henry F. Díaz

2003-08-01T23:59:59.000Z

494

Historical Records of Asian Dust Events (Hwangsa) in Korea  

Science Conference Proceedings (OSTI)

The observation of dust events in Korea must have been important through its long history because of its geographical and meteorological setting. Descriptions about dust events were well documented in historical archives, such as Samguk sagi (57 ...

Youngsin Chun; Hi-Ku Cho; Hyo-Sang Chung; Meehye Lee

2008-06-01T23:59:59.000Z

495

Historical Climate Records in China and Reconstruction of Past Climates  

Science Conference Proceedings (OSTI)

The principal results of studies on historical climate change from A.D. 1000 to the present in China are reviewed. The studies are based on analysis of local annals and court records. After discussing the methodology of transferring descriptive ...

Jiacheng Zhang; Thomas J. Crowley

1989-08-01T23:59:59.000Z

496

Historical review of Samsung's innovations and further steps  

E-Print Network (OSTI)

Samsung Group has been growing rapidly for the last ten years, based on Korean exclusive historical and economic backgrounds. Especially, Samsung Electronics, the biggest subsidiaries in the Samsung Group has grown very ...

Han, Jiwon, S.M. Massachusetts Institute of Technology

2011-01-01T23:59:59.000Z

497

Highly Radioactive Sludge Removal Complete: Historic Cleanup Effort Reduces  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Highly Radioactive Sludge Removal Complete: Historic Cleanup Effort Highly Radioactive Sludge Removal Complete: Historic Cleanup Effort Reduces the Risk along the Columbia River Highly Radioactive Sludge Removal Complete: Historic Cleanup Effort Reduces the Risk along the Columbia River September 13, 2012 - 12:00pm Addthis Media Contacts Cameron Salony, DOE Cameron.Salony@rl.doe.gov 509-376-0402 Dee Millikin, CH2M HILL Plateau Remediation Company Dee_Millikin@rl.gov 509-376-1297 RICHLAND, WASH. - The U.S. Department of Energy (DOE) and contractor CH2M HILL Plateau Remediation Company (CH2M HILL) announced today the removal of the first phase of highly radioactive sludge from under water storage in the K West Basin about 400 yards away from the Columbia River. "This is a major step forward in protecting the river and a historic

498

Highly Radioactive Sludge Removal Complete: Historic Cleanup Effort Reduces  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Highly Radioactive Sludge Removal Complete: Historic Cleanup Effort Highly Radioactive Sludge Removal Complete: Historic Cleanup Effort Reduces the Risk along the Columbia River Highly Radioactive Sludge Removal Complete: Historic Cleanup Effort Reduces the Risk along the Columbia River September 13, 2012 - 12:00pm Addthis Media Contacts Cameron Salony, DOE Cameron.Salony@rl.doe.gov 509-376-0402 Dee Millikin, CH2M HILL Plateau Remediation Company Dee_Millikin@rl.gov 509-376-1297 RICHLAND, WASH. - The U.S. Department of Energy (DOE) and contractor CH2M HILL Plateau Remediation Company (CH2M HILL) announced today the removal of the first phase of highly radioactive sludge from under water storage in the K West Basin about 400 yards away from the Columbia River. "This is a major step forward in protecting the river and a historic

499

Historic Virginia Market Powered by Solar Energy | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Historic Virginia Market Powered by Solar Energy Historic Virginia Market Powered by Solar Energy Historic Virginia Market Powered by Solar Energy November 3, 2010 - 11:00am Addthis Solar panels at the Community Market Building in Danville, Va., have generated 36.4 MWh of energy since March. | Photo Courtesy of Danville Solar panels at the Community Market Building in Danville, Va., have generated 36.4 MWh of energy since March. | Photo Courtesy of Danville Joshua DeLung The historic building where area farmers sell produce straight from the field to consumers is now home to Danville, Virg.'s first renewable energy project - a 154-panel solar energy system. The city, steeped in history, has taken this significant leap toward a new energy future by using a $202,000 Energy Efficiency and Conservation Block

500

NETL: News Release - Historically Black, Other Minority Colleges...  

NLE Websites -- All DOE Office Websites (Extended Search)

2004 ranging in value from 20,000 up to 200,000. A solicitation, Support of Advanced Fossil Resource Conversion and Utilization Research by Historically Black Colleges and...