High voltage electric substation performance in earthquakes  

SciTech Connect (OSTI)

This paper examines the performance of several types of high voltage substation equipment in past earthquakes. Damage data is provided in chart form. This data is then developed into a tool for estimating the performance of a substation subjected to an earthquake. First, suggests are made about the development of equipment class fragility curves that represent the expected earthquake performance of different voltages and types of equipment. Second, suggestions are made about how damage to individual pieces of equipment at a substation likely affects the post-earthquake performance of the substation as a whole. Finally, estimates are provided as to how quickly a substation, at various levels of damage, can be restored to operational service after the earthquake.

Eidinger, J. [G and E Engineering Systems, Oakland, CA (United States); Ostrom, D. [Southern California Edison, Rosemead, CA (United States); Matsuda, E. [Pacific Gas and Electric, San Francisco, CA (United States)

1995-12-31T23:59:59.000Z

2

Substation voltage upgrading  

SciTech Connect (OSTI)

This report addresses specific issues to support sound yet not unduly conservative uprating practices for substations. The main parts of the report cover the insulation withstand and overvoltage protection aspects, environmental measurements, reliability criteria, and industry experience. First the insulation design concerns are addressed. Substation stress by a backflashover of the line insulation due to lightning in the vicinity of the substation is recognized as a critical stress. A representative part of a 550 kV BIL substation was erected at the EPRI High Voltage Transmission Research Center, where also a special test circuit was assembled to produce a fast front, slow tail (0.2/200 {mu}s) wave. The substation as well as some special configurations were tested for line-to-ground and line-to-line withstand. Computer studies were performed to complement the test results. A number of important conclusions was reached. The most prominent result in that the high frequency oscillations, as caused by reflections within the substation, do not effect the Critical Flashover Voltage (CFO). The present practice, based on the highest peak is therefore very conservative. The slow tail of the wave appears to dictate the CFO. An arrester model for computer studies to represent very fast as well as slow phenomena was derived. It is based on full scale arrester test data, made available in this project. The computer program to calculate arrester model parameters is also a part of the report. The electric environmental measurements are reported for the tested substation at the HVTRC and for the uprated substation of Public Service Company of Colorado, both before and after the uprating. The performance is satisfactory when corona free hardware is used. Insulation design criteria are analyzed based on substation reliability, the system viewpoint and consequences of the failure. Utility experience with uprated substations is reviewed.

Panek, J.; Elahi, H.; Lux, A.; Imece, A.F. (General Electric Co., Schenectady, NY (United States). Power Systems Engineering Dept.); LaPanse, R.A.; Stewart, J.R. (Public Service Co. of Colorado, Denver, CO (United States))

1992-04-01T23:59:59.000Z

3

Substation voltage upgrading  

SciTech Connect (OSTI)

Substation voltage uprating, i.e., conversion of a substation from a lower rated voltage to a higher rated voltage without a complete substation rebuild, can lead to excellent economic benefits. Utilization of the old substation layout and/or the existing equipment, to some extent, is the practical objective of such an uprating. The objective of this project was to assess the opportunities for substation uprating in the industry, to establish feasibility for such uprating and to study methods for accomplishing it. The final aim of the project was to provide guidance to utilities interested in uprating. 56 refs., 41 figs., 18 tabs.

Panek, J.; Elahi, H.; Sublich, M. (General Electric Co., Schenectady, NY (USA). Systems Development and Engineering Dept.)

1989-08-01T23:59:59.000Z

4

Object Oriented Safety Analysis of an Extra High Voltage Substation Bay  

Science Journals Connector (OSTI)

Experiences of application of the object oriented approach to safety analysis of an extra high voltage substation bay are presented. As the first step...

Bartosz Nowicki; Janusz Górski

1998-01-01T23:59:59.000Z

5

Design of the Wireless Temperature Measurement Alarming System in the High-Voltage Transformer Substation  

Science Journals Connector (OSTI)

Due to electric power overload and equipment aging, fire and explosion occur at transmission circuitry joints in high-voltage transformer substation caused by high temperatures accumulated at these...

Qiang Gao; Hongli Wang; Huaxiang Wang

2008-01-01T23:59:59.000Z

6

Study of the electric field generated by the high voltage substations  

Science Journals Connector (OSTI)

The paper outlines the results of a study regarding the electromagnetic field generated by a 400 kV high voltage (HV) substation belonging to the Romanian national Power Grid Company Transelectrica SA. In the first part of the paper, a semi-analytical ... Keywords: HV substations, computation, electromagnetic field, human exposure, limits

Calin Munteanu; Vasile Topa; Marius Purcar; Laura Grindei; Adina Racasan

2010-10-01T23:59:59.000Z

7

Generalized charge simulation method for the calculation of the electric field in high voltage substations  

Science Journals Connector (OSTI)

This paper deals with the calculation of the electric field strength in high voltage (HV) substations comprising complex geometrical structures. Generalized charge simulation ... is to examine the influence of to...

Aleksandar Rankovi?; Milan S. Savi?

2010-07-01T23:59:59.000Z

8

Voltage stabilization system in traction substation of urban electric transport  

Science Journals Connector (OSTI)

The direct current-voltage stabilization system using a high-frequency link in traction substations of urban electric transport based on applying...

S. V. Shapiro; S. F. Muftiev

2011-02-01T23:59:59.000Z

9

The high-voltage substation configuration influence on the estimated lightning performance  

Science Journals Connector (OSTI)

The substation configuration has a great influence on the ... at the lines connected in front of the substations. In most of the analyses the critical substation configuration is assumed with only one connected ....

Z. Stojkovi?; M. S. Savi?

1997-08-01T23:59:59.000Z

10

Voltage asymmetry at the buses of a combined substation  

Science Journals Connector (OSTI)

The voltage asymmetry at the buses of a combined (ac/dc) substation is calculated by phase method, using Mathcad ... , power may be supplied to a combined substation along a common line from a limited-...

A. G. Pakulin; V. A. Zagorskii; V. F. Put’ko

2013-07-01T23:59:59.000Z

11

Reduction of interference on substation low voltage wiring  

SciTech Connect (OSTI)

This paper describes test results and mitigation methods of electromagnetic interference (EMI) on control and low voltage circuits in substations caused by air disconnect switch operation. The tests are focused on a comparison between unshielded and shielded circuits from capacitively coupled voltage transformers (CCVT) and other equipment circuits in the vicinity. New test data are presented comparing unshielded and shielded cables and transient currents on all connections to the CCVT including the pedestal and ground strap. The paper gives a practical and understandable explanation of the causes of EMI in substations and how shielded cable and parallel ground conductors reduce interference. Design guidelines are listed in the Conclusion.

Gavazza, R.J. [Pacific Gas and Electric Co., San Francisco, CA (United States)] [Pacific Gas and Electric Co., San Francisco, CA (United States); Wiggins, C.M. [Carl M. Wiggins and Associates, Friendswood, TX (United States)] [Carl M. Wiggins and Associates, Friendswood, TX (United States)

1996-07-01T23:59:59.000Z

12

Fuzzy Control on Voltage/Reactive Power in Electric Power Substation  

Science Journals Connector (OSTI)

A fuzzy method using in voltage and reactive power control in electric substation is proposed based on the improved 17 ... times at the tap positions of transformers in substation are much less than usual. So,...

Xiu-hua Wu; Jun-cheng Wang; Ping Yang…

2009-01-01T23:59:59.000Z

13

Variable Voltage Substation Electric Fire and Emergency Response  

Broader source: Energy.gov [DOE]

Variable Voltage Substation Electric Fire and Emergency Response My question is from an emergency response perspective. You stated that it took ~ ˝ for electricians to de-energize the electrical components before firefighters were allowed in to fight the fire. This delay causes more damage to equipment and potential propagation of the fire. Is there not a “master” breaker or switch? You’ve brought up a very good point. It gave me a good opportunity to discuss this with our Facilities Department and get a better understanding of the infrastructure upgrade plans. The direct answer to your question is “Yes, but…” Yes, there are “master” breakers and switches, but we can’t control them remotely. SLAC’s AC electrical distribution system at present is manual breakers – we have not installed the infrastructure to remotely control them (except see below). We recently underwent an upgrade to our Master Substation that will allow us to remotely control some high voltage breakers in the future, but we aren’t there yet. We do recognize the value in having this capability (and more importantly, our vulnerability in NOT having it), and have begun the preliminary planning to make this happen. One issue were are working on is cyber security for the power distribution networked infrastructure. Before we install the capability to remotely control the main electrical breakers, we are planning the infrastructure with our Information Technologies organization to ensure we have a robust secure network that is protected from unauthorized access. Once the cyber security issues are addressed and funded, we’re probably 5-10 years out from having remote operation capability due to limited resources to fund and install the infrastructure. Having said the above, we do have the capability of remotely opening the VVS Secondary Main Breakers – the ones that send power to the modulator distribution breakers - from our control room. Those breakers are integral parts of our safety systems in that interlock violation causes the breakers to open and remove power to the klystrons. But everything else is manual only. That remote operation capability would not have helped us in this case, as the VVS Secondary Main Breaker was the one that fried. We needed to open the breaker upstream of the VVS. Thanks for your interest. Let me know if I can provide further information.

14

ABBGroup-1-High voltage lab  

E-Print Network [OSTI]

;©ABBGroup-3- 3-Sep-07 Where does one use circuit breakers? High voltage (HV) circuit breakers are keyA DISTRIBUTION MEDIUM AND LOW VOLTAGE HV circuit breakers #12;©ABBGroup-4- 3-Sep-07 When a breaker fails to interrupt the current... Fault arc at a disconnector Fault arc in a substation #12;©ABBGroup-5- 3-Sep-07

Basse, Nils Plesner

15

The Application of Planning to Power Substation Voltage Control Keith Bell, Andrew Coles, Maria Fox, Derek Long and Amanda Smith  

E-Print Network [OSTI]

The Application of Planning to Power Substation Voltage Control Keith Bell, Andrew Coles, Maria Fox substations is a complex control task involving the coordination of interactions between cus- tomer demand and substation components. In this paper we look at the efficient management of substations in a pre-fault state

Coles, Andrew

16

Substation Expansion Planning  

Science Journals Connector (OSTI)

Consider an 11-load node case as depicted in Fig. 7.1..., fed in 33 kV and to be supplied through high-voltage (HV) substation(s) (say 230 kV:33 kV)... Fig. 7.1 ...

Hossein Seifi; Mohammad Sadegh Sepasian

2011-01-01T23:59:59.000Z

17

Research to Prevent the Anti-charging Incident of the Voltage Transformer in the Substation  

Science Journals Connector (OSTI)

The voltage transformer of the power system is a device which converts the high voltage of the primary side into the low voltage required by secondary device, and the primary side connects to the primary syste...

Hui-Ying Chen; Zhi-Peng Wang; Mu-Qin Tian

2011-01-01T23:59:59.000Z

18

ABBGroup-1-High voltage lab  

E-Print Network [OSTI]

A DISTRIBUTION MEDIUM AND LOW VOLTAGE HV circuit breakers #12;©ABBGroup-4- 3-Sep-07 When a breaker fails to interrupt the current... Fault arc at a disconnector Fault arc in a substation #12;©ABBGroup-5- 3-Sep-07/costs A detailed understanding of arc physics and fluid dynamics is necessary for the development of HV circuit

Basse, Nils Plesner

19

International Symposium on High Voltage Engineering, London, August 1999 page 1 of 4  

E-Print Network [OSTI]

substations (GIS) are described. Calculated transfer functions are presented, showing that transverse electric) in gas insulated substations (GIS) has been described in detail previously [1]. In this paper, we present that occurs somewhere in the insulating region between the high voltage (HV) conductor and the metal cladding

Judd, Martin

20

High-voltage engineering  

E-Print Network [OSTI]

High-voltage engineering covers the application, the useful use and proper working of high voltages and high fields. Here we give some introductory examples, i.e., ‘septa’ and ‘kicker’ at the Large Hadron Collider (14 TeV), the Super Proton Synchrotron (450 GeV) and the Proton Synchrotron (26 GeV) accelerators as found at the European Orginization for Nuclear Research (CERN) today. We briefly cover the theoretical foundation (Maxwell equations) and aspects of numerical field simulation methods. Concepts relating to electrical fields, insulation geometry and medium and breakdown are introduced. We discuss ways of generating high voltages with examples of AC sources (50/60 Hz), DC sources, and pulse sources. Insulation and breakdown in gases, liquids, solids and vacuum are presented, including Paschen’s law (breakdown field and streamer breakdown). Applications of the above are discussed, in particular the general application of a transformer. We briefly discuss measurement techniques of partial disch...

Gaxiola, E

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

HV Substation Earthing Design for Mines  

E-Print Network [OSTI]

Abstract:-High Voltage (HV) substation forms important assets for the mining industries. The existences of these substations necessitate earthing design to ensure safety compliance to the mine regulations. The HV system within the mines is consisted of multiple substations which are connected throughout and underground cable. These substations provide the load with the required electrical power to perform its tasks. This paper endeavours to provide information in regards to the different types of connections between the load and the substations (TT, TN and IT Systems). Furthermore, the earthing arrangements under different connection were assessed. A case study is addressed to show the different earthing arrangements under different connection systems Keywords:- Earth Grid, EPR, Fault Current, High Voltage, Mines, TN and TT systems I.

unknown authors

22

Assessment of precision timing and real-time data networks for digital substation automation.  

E-Print Network [OSTI]

??This project researched the performance of emerging digital technology for high voltage electricity substations that significantly improves safety for staff and reduces the potential impact… (more)

Ingram, David M.E.

2013-01-01T23:59:59.000Z

23

Chapter 3 - Substation Layouts  

Science Journals Connector (OSTI)

Publisher Summary Substations are the points in the power network, where transmission lines and distribution feeders are connected together through circuit breakers or switches via busbars and transformers. This allows for the control of power flows in the network and general switching operations for maintenance purposes. This chapter describes the principal substation layouts, the effects of advancements in substation equipment, the modular design, the compact substations, and the moves toward design and construction “turnkey” contract work. The descriptions concentrate on air insulated switchgear (AIS) outdoor open terminal designs at rated voltages of 72 kV and higher. In an ideal situation all circuits and substation equipment would be duplicated such that following a fault or during maintenance a connection remains available. This would involve very high cost. Methods have therefore been adopted to achieve a compromise between complete security of supply and capital investment. A measure of circuit duplication is adopted while recognizing that duplication may itself reduce the security of supply by, for example, providing additional leakage paths to earth.

C.R. Bayliss; B.J. Hardy

2012-01-01T23:59:59.000Z

24

High voltage pulse conditioning  

DOE Patents [OSTI]

Apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close.

Springfield, Ray M. (Sante Fe, NM); Wheat, Jr., Robert M. (Los Alamos, NM)

1990-01-01T23:59:59.000Z

25

High voltage DC power supply  

DOE Patents [OSTI]

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively. 7 figs.

Droege, T.F.

1989-12-19T23:59:59.000Z

26

High voltage DC power supply  

DOE Patents [OSTI]

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively.

Droege, Thomas F. (Batavia, IL)

1989-01-01T23:59:59.000Z

27

HV Substation Overvoltage Computation Taking into Account Frequency Dependent Transients on the Substation Grounding System  

E-Print Network [OSTI]

Abstract-This paper describes methodology for the computation of the electromagnetic transients in the high voltage substations, taking into account transients on the substation grounding system. Simulation technology is based on the system decomposition. Interconnections between different subsystems are done in each time step using Thevenin equivalents. Frequency dependent impedance of grounding conductors is represented by the parallel combination of resistance-inductance branches, to enable simulation in the time domain. Lightning overvoltage computation is performed for one particular 123 kV high voltage substation.

unknown authors

28

Living and Working Safely Around High-Voltage Power Lines.  

SciTech Connect (OSTI)

High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

United States. Bonneville Power Administration.

2001-06-01T23:59:59.000Z

29

Temperature controlled high voltage regulator  

DOE Patents [OSTI]

A temperature controlled high voltage regulator for automatically adjusting the high voltage applied to a radiation detector is described. The regulator is a solid state device that is independent of the attached radiation detector, enabling the regulator to be used by various models of radiation detectors, such as gas flow proportional radiation detectors.

Chiaro, Jr., Peter J. (Clinton, TN); Schulze, Gerald K. (Knoxville, TN)

2004-04-20T23:59:59.000Z

30

Transient electromagnetic interference in substations  

SciTech Connect (OSTI)

Electromagnetic interference levels on sensitive electronic equipment are quantified experimentally and theoretically in air and gas insulated substations of different voltages. Measurement techniques for recording interference voltages and currents and electric and magnetic fields are reviewed and actual interference data are summarized. Conducted and radiated interference coupling mechanisms and levels in substation control wiring are described using both measurement results and electromagnetic models validated against measurements. The nominal maximum field and control wire interference levels expected in the switchyard and inside the control house from switching operations, faults, and an average lightning strike are estimated using high frequency transient coupling models. Comparisons with standards are made and recommendations given concerning equipment shielding and surge protection.

Wiggins, C.M.; Thomas, D.E.; Nickel, F.S.; Salas, T.M. (BDM International, Inc., Albuquerque, NM (United States)); Wright, S.E. (Electric Power Research Inst., Palo Alto, CA (United States))

1994-10-01T23:59:59.000Z

31

High-Voltage Test Laboratories  

Science Journals Connector (OSTI)

The power for a complete HV laboratory is usually supplied from a medium-...9.20...). One or several three-phase distribution transformers in a nearby substation should be used for that purpose. Their...Sect. 9.2...

Wolfgang Hauschild; Eberhard Lemke

2014-01-01T23:59:59.000Z

32

Microsoft Word - CX_DeMoss_Substation_Expansion_130531  

Broader source: Energy.gov (indexed) [DOE]

Alaric Hsu Alaric Hsu Project Manager - TEP-CSB-2 Proposed Action: De Moss Substation Expansion Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.6 Additions and modifications to transmission facilities Location: Sherman County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to expand its De Moss Substation yard located in Sherman County, Oregon. The expansion is necessary to install additional reactors that would provide the necessary reactive support to address the extreme high voltage at De Moss Substation resulting from the loss of the Big Eddy - DeMoss transmission line during winter peak conditions. The equipment at De Moss Substation is currently sustaining voltage

33

Substation grounding.  

E-Print Network [OSTI]

??Designing a proper substation grounding system is quite complicating. Many parameters affect its design. In order for a grounding design to be safe, it needs… (more)

Baleva, Inna

2012-01-01T23:59:59.000Z

34

Substation grounding programs  

SciTech Connect (OSTI)

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. This report, Volume 3, is a users manual and an installation and validation manual for the computer program SGSYS (Substation Grounding SYStem Analysis Program). This program analyzes the substation ground field given the total electric current injected into the ground field and the design of the grounding system. Standard outputs of the program are (1) total ground resistance, (2) step voltage, (3) touch voltage, (4) voltages on a grid of points, (5) voltage profile along straight lines, (6) transfer voltages, (7) ground potential rise, (8) body currents, (9) step voltage profile along straight lines, and (10) touch voltage profile along straight lines. This program can be utilized in an interactive or batch mode. In the interactive mode, the user defines the grounding system geometry, soil parameters, and output requests interactively, with the use of a user friendly conversational program. The users manual describes data requirements and data preparation procedures. An appendix provides forms which facilitate data collection procedures. The installation and validation manual describes the computer files which make up the program SGSYS and provides a test case for validation purposes.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

35

High voltage RF feedthrough bushing  

DOE Patents [OSTI]

Described is a multi-element, high voltage radio frequency bushing for trmitting RF energy to an antenna located in a vacuum container. The bushing includes a center conductor of complex geometrical shape, an outer coaxial shield conductor, and a thin-walled hollow truncated cone insulator disposed between central and outer conductors. The shape of the center conductor, which includes a reverse curvature portion formed of a radially inwardly directed shoulder and a convex portion, controls the uniformity of the axial surface gradient on the insulator cone. The outer shield has a first substantially cylindrical portion and a second radially inwardly extending truncated cone portion.

Grotz, Glenn F. (Huntington Station, NY)

1984-01-01T23:59:59.000Z

36

Substation Operation  

Science Journals Connector (OSTI)

... THIS book is intended to help the workman to understand the principles of substation operation. It is a good attempt at giving somewhat advanced technical knowledge in such ... ." We are told not to use water to put out a fire at a substation before the station has been made completely " dead." The reason given for this ...

1925-08-01T23:59:59.000Z

37

Seismic vulnerability assessment of a high voltage disconnect switch  

Science Journals Connector (OSTI)

Abstract This paper deals with the seismic vulnerability of high voltage equipment typically installed in electric substations. In particular, the seismic response of a 380 kV vertical disconnect switch has been investigated based on the results of an experimental campaign carried out at Roma Tre University. According to a series of non-linear analyses, the influence of the most significant parameters on the seismic behavior of this apparatus has been analyzed and the corresponding fragility curves have been evaluated by using the Effective Fragility Analysis method. The results showed a limited vulnerability of the disconnect switch, whose most critical parts are the bottom joint of the ceramic support column and the steel column base.

Fabrizio Paolacci; Renato Giannini; Silvia Alessandri; Gianmarco De Felice

2014-01-01T23:59:59.000Z

38

High Voltage Electrolyte for Lithium Batteries  

Broader source: Energy.gov (indexed) [DOE]

battery using high voltage high energy cathode materials to enable large-scale, cost competitive production of the next generation of electric-drive vehicles. To...

39

High voltage load resistor array  

DOE Patents [OSTI]

A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

Lehmann, Monty Ray (Smithfield, VA)

2005-01-18T23:59:59.000Z

40

Substation grounding programs  

SciTech Connect (OSTI)

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. This report, Volume 2, is a users manual and an installation and validation manual for the computer program SMECC (Substation Maximum Earth Current Computation Program). This program analyzes the electric current distribution among grounded structures inside and outside a substation for different fault conditions. The fault conditions are automatically selected by the program, or they may be specified by the user, or both. The fault condition resulting in maximum substation earth current is identified and reported. Data requirements for this program are: ground impedance, transformer data, transmission line data, transmission line grounding impedances, etc. The program provides four types of standard outputs: (1) a report of voltages and current flow in the unfaulted system, (2) a brief report of the maximum ground potential rise (worst fault condition), (3) a summary report of all fault conditions which have been analyzed by the program, and (4) a detailed report of voltages and current flow for a selected set of fault conditions.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

High-Capacity Hybrid Active Power Filter for the Power Substation  

Science Journals Connector (OSTI)

Non-linear loads, such as diode, thyristor converters and arc furnaces are typical sources of harmonic currents. A capacitor clamped voltage source inverter for high-capacity hybrid active power filter (HHAPF)...

Fen Gong; Xiangyang Xia; Shiwu Luo…

2012-01-01T23:59:59.000Z

42

Recent developments in subtransmission substations  

SciTech Connect (OSTI)

Equipment is described which offers the utility engineer flexibility in the layout and location of substations. It is possible with these designs to place HV connected substations directly into load centers and reduce the losses with connections at a lower voltage level. An added advantage of these designs are reduced expenses for engineering, site preparation, foundations, installation and interest payments due to the shorter time between equipment delivery and possible energization of a substation. Reduced maintenance, longer maintenance intervals, small gas leakage, are built-in advantages of this equipment.

Watson, P.W.; Leibold, A.A.; Koglin, B.B.

1980-05-01T23:59:59.000Z

43

Development of High Voltage Electron Microscope  

Science Journals Connector (OSTI)

......Cockcroft Walton Type High Voltage Generator. O Power Line O Fig. 4...pressure in the tank to the atmospheric pressure by removing freon...pump using liquid nitrogen. Water buffer and liquid nitrogen...base plate of high voltage generator. Four poles stand on this......

Shinjiro KATAGIRI; Hirokazu KIMURA; Susumu OZASA; Kazumi SHIRAISHI

1969-01-01T23:59:59.000Z

44

Limitations of High-Voltage Insulation  

Science Journals Connector (OSTI)

... materials such as impregnated paper. The important electrical properties of the materials used for the insulation of high-voltage circuits are conductivity and electric strength. The conductivity measures the ability ... a million times between themselves, but they are all classified as available for high-voltage insulation.

1938-01-08T23:59:59.000Z

45

High Voltage Safety Act | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

High Voltage Safety Act High Voltage Safety Act High Voltage Safety Act < Back Eligibility Commercial Construction Developer General Public/Consumer Industrial Installer/Contractor Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Georgia Program Type Safety and Operational Guidelines Siting and Permitting The purpose of the High Voltage Safety Act is to prevent injury to persons and property and interruptions of utility service resulting from accidental or inadvertent contact with high-voltage electric lines by providing that no work shall be done in the vicinity of such lines unless and until the owner or operator thereof has been notified of such work and has taken the appropriate safety measures. The Georgia Public Service Commission requires

46

Integrating modified Delphi method with fuzzy AHP for optimal power substation location selection  

Science Journals Connector (OSTI)

Evaluation and selection of power substation location is an important strategic decision making problem for both public and private sector. The multi-dimensional, multi-criteria nature of the power substation location problem limits the usefulness of any particular single objective model. Studies have shown that electromagnetic radiations emanating from the high voltage lines and substations, pose serious adverse health consequences to living beings. In this study, social, technological, economical, environmental and site characteristics factors and sub criteria, have been derived to make the optimal power substation location selection decision more realistic and effectual. In this paper, an improved and more appropriate power substation location evaluation and selection model has been developed by integrating Modified Delphi method with Fuzzy Analytic Hierarchy Process (FAHP). A numerical example is presented to show applicability and performance of the proposed methodology followed by a sensitivity analysis to discuss and explain the results.

Golam Kabir; M. Ahsan Akhtar Hasin

2013-01-01T23:59:59.000Z

47

Power substation location selection using fuzzy analytic hierarchy process and PROMETHEE: A case study from Bangladesh  

Science Journals Connector (OSTI)

Abstract Electromagnetic radiations emanating from the high voltage lines and substations pose serious adverse health consequences to living beings. As a result, selection of power substation location is an important strategic decision-making problem for both public and private sectors. In general, many conflicting factors affect the appropriate substation location selection problem which adheres to uncertain and imprecise data. In this paper, a simple, systematic and logical scientific approach is structured to evaluate power substation location through integrating Fuzzy Analytical Hierarchy Process (FAHP) with the Preference Ranking Organization Method for Enrichment Evaluations (PROMETHEE). The proposed integrated approach provides more realistic and reliable results, and facilitates the decision-maker to handle multiple contradictory decision perspectives through eliminating the limitations of FAHP and PROMETHEE methods. To accredit the proposed model, it is implemented in a power substation location selection problem in Bangladesh.

Golam Kabir; Razia Sultana Sumi

2014-01-01T23:59:59.000Z

48

EA-1671: Big River Substation to Poston Substation 69-Kilovolt...  

Broader source: Energy.gov (indexed) [DOE]

671: Big River Substation to Poston Substation 69-Kilovolt Transmission Line Project, Arizona and California EA-1671: Big River Substation to Poston Substation 69-Kilovolt...

49

CHARACTERISTICS OF IMPULSIVE NOISE IN ELECTRICITY SUBSTATIONS Qingshan Shan1  

E-Print Network [OSTI]

CHARACTERISTICS OF IMPULSIVE NOISE IN ELECTRICITY SUBSTATIONS Qingshan Shan1 , Shahzad Bhatti1.shan@eee.strath.ac.uk, website: www.strath.ac.uk ABSTRACT Measurements of noise in an electricity substation are re- ported-voltage electricity substations, has discouraged electricity utility companies from deploying wireless technologies

Atkinson, Robert C

50

Substation alarm multiplexing system (SAMS)  

SciTech Connect (OSTI)

This paper describes an on going R&D project to develop, design, install, and assess the field performance of an advanced substation alarm system. SAMS provides a highly fault-tolerant system for the reporting of equipment alarms. SAMS separates and identifies each of the multiple alarm contacts, transmits an alarm condition over existing substation two-wire system, and displays the alarm source, and its associated technical information, on a touch-screen monitor inside the substation control room, and a remote central location and on a hand held terminal which may be carried anywhere within the substation. SAMS is currently installed at the Sherman Creek substation in the Bronx for the purpose of a three month field evaluation.

ElBadaly, H.; Gaughan, J.; Ward, G.; Amengual, S.

1996-03-01T23:59:59.000Z

51

Vehicle Technologies Office Merit Review 2014: High-Voltage Solid...  

Broader source: Energy.gov (indexed) [DOE]

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles Vehicle Technologies Office Merit Review 2014: High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...

52

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...  

Broader source: Energy.gov (indexed) [DOE]

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2013 DOE Hydrogen and Fuel Cells Program and...

53

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2012 DOE Hydrogen and Fuel Cells Program and...

54

High Voltage Testing of a 5-meter Prototype Triaxial HTS Cable  

SciTech Connect (OSTI)

High voltage tests were performed on a 5-m long prototype triaxial HTS cable (supplied by Ultera) at ORNL in preparation for installation of a 200-m HTS cable of the same design at the AEP utility substation in Columbus, Ohio. The triaxial design comprises three concentric phases and shield around a common former with the phase to phase dielectric at cryogenic temperature. Advantages of this design include increased current density, a reduced amount of HTS tape needed, and reduced heat load. The phase to phase voltage will be 13.2 kVrms (7.6 kVrms to ground). Preliminary testing was done on half-scale and full-scale terminations which successfully passed AC withstand, partial discharge, and impulse tests. High voltage tests conducted on the 5-m cable with the cable straight and after bending 90 degrees were ac withstand to 39 kVrms, partial discharge inception, and a minimum of 10 positive and 10 negative lightning waveform impulses at 110 kV. Phase to phase insulation was tested by applying high voltage to each phase one at a time with all the other phases grounded. Partial discharge data will be presented. The 5-m prototype triaxial HTS cable passed all the HV tests performed, with a PD inception voltage significantly above the required voltage.

Sauers, Isidor [ORNL; James, David Randy [ORNL; Ellis, Alvin R [ORNL; Tuncer, Enis [ORNL; Pace, Marshall O [ORNL; Gouge, Michael J [ORNL; Demko, Jonathan A [ORNL; Lindsay, David T [ORNL

2007-01-01T23:59:59.000Z

55

Modular high voltage power supply for chemical analysis  

DOE Patents [OSTI]

A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2010-05-04T23:59:59.000Z

56

Impact of electric vehicles on distribution substations: A Swiss case study  

Science Journals Connector (OSTI)

Abstract An increasing number of electric vehicles (EVs) will have a significant impact on the electricity grids. For target grid planning, it is essential to identify and quantify this impact in terms of local infrastructure overloads. We study the impact of EV charging loads on Swiss distribution substations under different penetration levels and pricing regimes. Unlike mainly conceptual studies focusing on generic distribution grids, we use real data—driving profiles matched to regional circumstances, Swiss substation capacity and load data in the high-voltage grid together with electricity prices—as the main data inputs. To reflect current regulation and contracting schemes, we apply decentral decision-making instead of central control. The results indicate that under a flat electricity tariff and EV penetration levels around 16% the current substation capacity will be sufficient to cover additional EV charging load. However, beyond penetration levels of 50% an increasing number of substations will be overloaded. More significantly, the introduction of dynamic electricity prices can further increase the risk of substation overloads. These results show that EV charging loads can also cause bottlenecks on substations in the high-voltage grid.

Florian Salah; Jens P. Ilg; Christoph M. Flath; Hauke Basse; Clemens van Dinther

2015-01-01T23:59:59.000Z

57

High voltage overhead long transmission line design and fault analysis.  

E-Print Network [OSTI]

??The goal of this project is to design a reliable high voltage overhead long transmission line that satisfies specific design criteria including voltage regulation, efficiency,… (more)

Elzain, Mohamed Ali

2011-01-01T23:59:59.000Z

58

Electro-optic high voltage sensor  

DOE Patents [OSTI]

A small sized electro-optic voltage sensor capable of accurate measurement of high levels of voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation into the sensor. A polarization beam displacer serves as a filter to separate the input beam into two beams with orthogonal linear polarizations. The beam displacer is oriented in such a way as to rotate the linearly polarized beams such that they enter a Pockels crystal having at a preferred angle of 45 degrees. The beam displacer is therefore capable of causing a linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels electro-optic effect induces a differential phase shift on the major and minor axes of the input beam as it travels through the Pockels crystal, which causes the input beam to be elliptically polarized. A reflecting prism redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization representing the major and minor axes. The system may include a detector for converting the output beams into electrical signals, and a signal processor for determining the voltage based on an analysis of the output beams. The output beams are amplitude modulated by the frequency of the electric field and the amplitude of the output beams is proportional to the magnitude of the electric field, which is related to the voltage being measured.

Davidson, James R. (Idaho Falls, ID); Seifert, Gary D. (Idaho Falls, ID)

2002-01-01T23:59:59.000Z

59

Earth resistivity measurement near substation ground grids  

SciTech Connect (OSTI)

Proper substation grounding grid design requires good, accurate soil resistivity measurements. This data is essential to model the substation ground grid to design a safe ground grid with a satisfactory ground grid resistance at minimum cost. For substations with several decades of service, there is some concern that a grid may have deteriorated, been damaged during equipment installation or excavation, or that initial soil resistivity measurements were lost or may not have been correctly performed. Ground grid conductors change the substation surface voltage distribution. Any voltage measurements taken at the complete substation will also vary from the tests made without conductors present. During testing, current was injected in the soil by probes placed near the ground grid. The current tends to follow the ground grid conductors since copper is a far better conductor than the soil it is placed in. Resistance readings near grids will be lower than readings in undisturbed soil. Since computer models were unavailable for many years, analyzing the effect of the grid conductors on soil resistivity measurements was very difficult. As a result, soil resistivity measurements made close to substations were of little use to the engineer unless some means of correcting the measured values could be developed. This paper will present results of soil resistivity measurements near a substation ground grid before and after a ground grid has been installed and describes a means of calculating the undisturbed soil model.

Lodwig, S.G.; Mateja, S.A. [ComEd, Chicago, IL (United States)

1996-11-01T23:59:59.000Z

60

A High Voltage Direct Current Generator  

Science Journals Connector (OSTI)

When powdered materials are blown through metal tubes by means of compressed air considerable quantities of electricity are produced by contact electrification. It was found that 6×10-5 coulombs could be produced per gram of diatomaceous earth, a form of silica, blown through a short length of copper tube. A generator of extremely high voltage is proposed, and a small scale model of such a generator is described, by means of which currents of 8×10-5 amperes at 260 kilovolts were generated.

Richard E. Vollrath

1932-10-15T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Safe epoxy encapsulant for high voltage magnetics  

SciTech Connect (OSTI)

This paper describes the use of Formula 456, an aliphatic amine cured epoxy for impregnating coils and high voltage transformers. Sandia has evaluated a number of MDA-free epoxy encapsulants which relied on either anhydride or other aromatic amine curing agents. The use of aliphatic amine curing agents was more recently evaluated and has resulted in the definition of Formula 456 resin. Methylene dianiline (MDA) has been used for more than 20 years as the curing agent for various epoxy formulations throughout the Department of Energy and much of industry. Sandia National Laboratories began the process of replacing MDA with other formulations because of regulations imposed by OSHA on the use of MDA. OSHA has regulated MDA because it is a suspect carcinogen. Typically the elimination of OSHA-regulated materials provides a rare opportunity to qualify new formulations in a range of demanding applications. It was important to take full advantage of that opportunity, although the associated materials qualification effort was costly. Small high voltage transformers are one of those demanding applications. The successful implementation of the new formulation for high reliability transformers will be described. The test results that demonstrate the parts are qualified for use in DOE weapon systems will be presented.

Sanchez, R.O.; Archer, W.E.

1998-01-01T23:59:59.000Z

62

An algorithm for faulted phase and feeder selection under high impedance fault conditions  

E-Print Network [OSTI]

substation. One-line diagram of a distribution system with two feeders. Typical high impedance fault, showing little or no change in phase voltage due to the fault. . Phase voltage and high frequency current component during a staged high impedance... substation. One-line diagram of a distribution system with two feeders. Typical high impedance fault, showing little or no change in phase voltage due to the fault. . Phase voltage and high frequency current component during a staged high impedance...

Benner, Carl Lee

2012-06-07T23:59:59.000Z

63

Accelerator System Development at High Voltage Engineering  

SciTech Connect (OSTI)

Throughout the years, HVE has continuously extended the capabilities of its accelerator systems to meet the rising demands from a diverse field of applications, among which are deep level ion implantation, micro-machining, neutron production for biomedical research, isotope production or accelerator mass spectrometry. Characteristic for HVE accelerators is the coaxial construction of the all solid state power supply around the acceleration tubes. With the use of solid state technology, the accelerators feature high stability and very low ripple. Terminal voltages range from 1 to 6 MV for HVE Singletrons and Tandetrons. The high-current versions of these accelerators can provide ion beams with powers of several kW. In the last years, several systems have been built with terminal voltages of 1.25 MV, 2 MV and 5 MV. Recently, the first system based on a 6 MV Tandetron has passed the factory tests. In this paper we describe the characteristics of the HVE accelerator systems and present as example recent systems.

Klein, M. G.; Gottdang, A.; Haitsma, R. G.; Mous, D. J. W. [High Voltage Engineering Europa B.V., P.O. Box 99, Amersfoort 3800 AB (Netherlands)

2009-03-10T23:59:59.000Z

64

The design, construction, and operation of long-distance high-voltage electricity transmission technologies.  

SciTech Connect (OSTI)

This report focuses on transmission lines, which operate at voltages of 115 kV and higher. Currently, the highest voltage lines comprising the North American power grid are at 765 kV. The grid is the network of transmission lines that interconnect most large power plants on the North American continent. One transmission line at this high voltage was built near Chicago as part of the interconnection for three large nuclear power plants southwest of the city. Lines at this voltage also serve markets in New York and New England, also very high demand regions. The large power transfers along the West Coast are generally at 230 or 500 kV. Just as there are practical limits to centralization of power production, there are practical limits to increasing line voltage. As voltage increases, the height of the supporting towers, the size of the insulators, the distance between conductors on a tower, and even the width of the right-of-way (ROW) required increase. These design features safely isolate the electric power, which has an increasing tendency to arc to ground as the voltage (or electrical potential) increases. In addition, very high voltages (345 kV and above) are subject to corona losses. These losses are a result of ionization of the atmosphere, and can amount to several megawatts of wasted power. Furthermore, they are a local nuisance to radio transmission and can produce a noticeable hum. Centralized power production has advantages of economies of scale and special resource availability (for instance, hydro resources), but centralized power requires long-distance transfers of power both to reach customers and to provide interconnections for reliability. Long distances are most economically served at high voltages, which require large-scale equipment and impose a substantial footprint on the corridors through which power passes. The most visible components of the transmission system are the conductors that provide paths for the power and the towers that keep these conductors at a safe distance from each other and from the ground and the natural and built environment. Common elements that are generally less visible (or at least more easily overlooked) include the maintained ROW along the path of the towers, access roads needed for maintenance, and staging areas used for initial construction that may be restored after construction is complete. Also visible but less common elements along the corridor may include switching stations or substations, where lines of similar or different voltages meet to transfer power.

Molburg, J. C.; Kavicky, J. A.; Picel, K. C.

2008-03-03T23:59:59.000Z

65

Low voltage amplifier architecture for high speed switched capacitor circuits  

E-Print Network [OSTI]

This work concentrates on circuit realization of high speed and low voltage switched capacitor circuits, with emphasis on the operational transconductance amplifier (OTA). An overview of switched capacitor circuits is given. Speed and voltage...

Shankar, Asit

2012-06-07T23:59:59.000Z

66

Qualification High Voltage Testing of Short Triax HTS Cables in the Laboratory  

SciTech Connect (OSTI)

In order to qualify the electrical insulation design of future HTS cables installed in the electric grid, a number of high voltage qualification tests are generally performed in the laboratory on either single-phase model cables and/or actual three-phase cable samples. Prior to installation of the 200-m Triax HTS cable at the American Electric Power Bixby substation near Columbus, Ohio, in September, 2006, such tests were conducted on both single-phase model cables made at ORNL and tri-axial cable sections cut off from cable made on a production run. The three-phase tri-axial design provides some specific testing challenges since the ground shield and three phases are concentric about a central former with each phase separated by dielectric tape insulation immersed in liquid nitrogen. The samples were successfully tested and qualified for partial discharge inception, AC withstand, and lightning impulse where voltage is applied to one phase with the other phases grounded. In addition one of the phase pairs was tested for dc withstand as a ldquoworst caserdquo scenario to simulate the effect of VLF (Very Low Frequency) tests on the actual cable installed at the Bixby site. The model and prototype cables will be described and the high voltage test results summarized.

James, David Randy [ORNL; Sauers, Isidor [ORNL; Ellis, Alvin R [ORNL; Tuncer, Enis [ORNL; Gouge, Michael J [ORNL; Demko, Jonathan A [ORNL; Duckworth, Robert C [ORNL; Rey, Christopher M [ORNL

2009-01-01T23:59:59.000Z

67

The implementation of substation automation coordinated with numerical protection relaying  

SciTech Connect (OSTI)

During 1987 Eskom embarked on a process of defining user requirements in the area of substation control. This ultimately resulted in a project being established for the procurement and development of a new generation of substation control equipment. At the same time it was decided to establish a new generation of protection schemes for transmission substations, based on numerical protection relays. From the outset, a high degree of coordination was planned between the substation control and protection equipment. Development contracts were placed with suppliers during late 1990 for the protection schemes and during early 1991 for the substation control equipment. These contracts are nearing completion and the first large installations will commence during 1994. The Transmission Group has committed to employing this new technology in all new substations and all substations to be refurbished. This paper discusses the concept of coordinated substation control and protection and gives insight into implementation issues and functional compromises which had to be made to meet project deadlines.

Welie, G. van; Carolin, T.

1994-12-31T23:59:59.000Z

68

fault diagnosis of a high voltage transmission line using waveform ...  

E-Print Network [OSTI]

Oct 4, 2013 ... FAULT DIAGNOSIS OF A HIGH VOLTAGE TRANSMISSION LINE USING ... Fault types such as single line to ground, line to line, double line to ...

Ripunjoy Phukan

2013-10-04T23:59:59.000Z

69

Substation fire protection features  

SciTech Connect (OSTI)

This paper describes Commonwealth Edison`s (ComEd) approach to substation fire protection. Substation fires can have a major operational, financial, as well as political impact on a utility. The overall Company philosophy encompasses both active and passive fire protection features to provide prompt detection, notification, and confinement of fire and its by-products. Conservatively designed smoke detection systems and floor and wall penetration seals form the backbone of this strategy. The Company has implemented a program to install these features in new and existing substations. Thus far these measures have been successful in mitigating the consequences of substation fires.

Hausheer, T.G. [Commonwealth Edison Co., Chicago, IL (United States)

1995-10-01T23:59:59.000Z

70

Substation PSA Model  

Science Journals Connector (OSTI)

Chapter 6 describes how to create the substation model, the core of the PSA application... Chap. 4 . First, the modelling principles and then the details of the mode...

Liisa Haarla; Mikko Koskinen; Ritva Hirvonen…

2011-01-01T23:59:59.000Z

71

Substation grounding optimization.  

E-Print Network [OSTI]

??Substation grounding is a critical part of the overall electric power system. It is designed to not only provide a path to dissipate electric currents… (more)

Balev, Vadim

2014-01-01T23:59:59.000Z

72

Integrating fuzzy AHP with TOPSIS method for optimal power substation location selection  

Science Journals Connector (OSTI)

Electromagnetic radiations emanating from the high voltage lines and substations pose serious adverse health consequences to living beings. As a result, evaluation and selection of power substation location is an important strategic decision making problem for both public and private sector. In this paper, fuzzy analytic hierarchy process (FAHP) has been integrated with technique for order preference by similarity to an ideal solution (TOPSIS) method to develop an improved and more appropriate power substation location evaluation and selection model considering social, technological, economical, environmental and site characteristics factors and sub criteria. The proposed decision-making approach takes advantage of the synergy between these two well-known multi-criteria analysis (MCA) methods. A numerical example is presented to show applicability and performance of the proposed methodology followed by a sensitivity analysis to discuss and explain the results.

Golam Kabir; M. Ahsan Akhtar Hasin

2013-01-01T23:59:59.000Z

73

Ventilation of Electrical Substations  

Science Journals Connector (OSTI)

... THE type of construction used for substations is generally governed by requirements, for example, fire and air-raid precautions, which ... Electrical Engineers, F. Favell and E. W. Connon record their experiences in overcoming substation ventilation problems in particular cases. Adequate and suitably planned ventilation will maintain ...

1943-05-01T23:59:59.000Z

74

Measurement of high voltage using Rutherford backscattering spectrometry  

E-Print Network [OSTI]

A novel variation of Rutherford Backscattering Spectrometry (RBS) has been utilized to measure a high voltage collected on an aluminum target by Direct Energy Conversion. The maximum high voltage on the target was measured to be 97.5 kV +/- 2 kV...

Abrego, Celestino Pete

2007-04-25T23:59:59.000Z

75

The Cavendish high-voltage laboratory 1935–39  

Science Journals Connector (OSTI)

...the period covered. Nuclear Transmutation|Cavendish...development of high-voltage nuclear transmutation equipment...experimental work in nuclear physics though he continued...a new high-voltage accelerator therefore fell mainly...doubler circuit with six vacuum rectifiers forming a...

1999-01-01T23:59:59.000Z

76

Monte Carlo method for estimating backflashover rates on high voltage transmission lines  

Science Journals Connector (OSTI)

Abstract This paper presents a novel Monte-Carlo based model for the analysis of backflashover rate (BFOR) on high voltage transmission lines. The proposed model aims to take into the account following aspects of the BFOR phenomenon: transmission line (TL) route keraunic level(s), statistical depiction of lightning-current parameters (including statistical correlation), electrogeometric model of lightning attachment, frequency-dependence of TL parameters and electromagnetic coupling effects, tower geometry and surge impedance, tower grounding impulse impedance (with soil ionization), lightning-surge reflections from adjacent towers, non-linearity of the insulator strings flashover characteristic, distribution of lightning strokes along the TL span and power frequency voltage. In the analysis of the BFOR, special attention is given to the influences emanating from the insulator strings flashover characteristic and lightning statistics. The model could be applied to the transmission line as a whole or some of its portions, e.g. first several towers emanating from the substation or several towers crossing a mountain ridge.

Petar Sarajcev

2015-01-01T23:59:59.000Z

77

Substation Configuration Reliability 1 Reliability of Substation Configurations  

E-Print Network [OSTI]

Substation Configuration Reliability 1 Reliability of Substation Configurations Daniel Nack, Iowa substation, it still contains what could be described as weak points or points of failure that would lead to loss of load. By knowing how to calculate the reliability of different substation configurations

McCalley, James D.

78

Sundial Substation Site Baxter Road Substation Site Casey Road  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Sundial Substation Site Baxter Road Substation Site Casey Road Substation Site Monahan Creek Substation Site YALE DAM MERWIN DAM S i l v e r L a k e Lake Merwin Y a l e L a k e V a...

79

Research and Application of FlexRay High-Speed Bus on Transformer Substation Automation System  

Science Journals Connector (OSTI)

Through researching FlexRay high-speed bus technology, this paper auxiliary builds electric power system hardware interface standards and software application layer standards. Meanwhile, this paper also realizes ...

Hui Li; Hao Zhang; Daogang Peng

2010-01-01T23:59:59.000Z

80

Electrical system architecture having high voltage bus  

DOE Patents [OSTI]

An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

Hoff, Brian Douglas (East Peoria, IL); Akasam, Sivaprasad (Peoria, IL)

2011-03-22T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage put under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1996-01-01T23:59:59.000Z

82

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 figs.

Shimer, D.W.; Lange, A.C.

1996-10-15T23:59:59.000Z

83

High-voltage air-core pulse transformers  

SciTech Connect (OSTI)

General types of air core pulse transformers designed for high voltage pulse generation and energy transfer applications are discussed with special emphasis on pulse charging systems which operate up to the multi-megavolt range. The design, operation, dielectric materials, and performance are described. It is concluded that high voltage air core pulse transformers are best suited to applications outside the normal ranges of conventional magnetic core transformers. In general these include charge transfer at high power levels and fast pulse generation with comparatively low energy. When properly designed and constructed, they are capable of delivering high energy transfer efficiency and have demonstrated superior high voltage endurance. The principal disadvantage of high voltage air core transformers is that they are not generally available from commercial sources. Consequently, the potential user must become thoroughly familiar with all aspects of design, fabrication and system application before he can produce a high performance transformer system. (LCL)

Rohwein, G. J.

1981-01-01T23:59:59.000Z

84

Optically triggered high voltage switch network and method for switching a high voltage  

DOE Patents [OSTI]

An optically triggered solid state switch and method for switching a high voltage electrical current. A plurality of solid state switches (350) are connected in series for controlling electrical current flow between a compensation capacitor (112) and ground in a reactive power compensator (50, 50') that monitors the voltage and current flowing through each of three distribution lines (52a, 52b and 52c), which are supplying three-phase power to one or more inductive loads. An optical transmitter (100) controlled by the reactive power compensation system produces light pulses that are conveyed over optical fibers (102) to a switch driver (110') that includes a plurality of series connected optical triger circuits (288). Each of the optical trigger circuits controls a pair of the solid state switches and includes a plurality of series connected resistors (294, 326, 330, and 334) that equalize or balance the potential across the plurality of trigger circuits. The trigger circuits are connected to one of the distribution lines through a trigger capacitor (340). In each switch driver, the light signals activate a phototransistor (300) so that an electrical current flows from one of the energy reservoir capacitors through a pulse transformer (306) in the trigger circuit, producing gate signals that turn on the pair of serially connected solid state switches (350).

El-Sharkawi, Mohamed A. (Renton, WA); Andexler, George (Everett, WA); Silberkleit, Lee I. (Mountlake Terrace, WA)

1993-01-19T23:59:59.000Z

85

Inter substation data communications  

SciTech Connect (OSTI)

The paper briefly describes the scada system operated by ComEd for substation communications. This system has proven a reliable means for monitor and control of the generation, transmission, and distribution system. An attempt to automate stand-alone substation functions into the RTU has had limited success. An automated substation capacitor control algorithm was incorporated into a PC. The PC directly interfaced with the RTU through the serial port for analog monitoring and control of the capacitor banks. There were no further enhancements or development of other control algorithms with the PC. The paper discusses the power system data evolution, the proposed design improvements, and implementation concerns.

Lukas, M.R. [ComEd, Chicago, IL (United States)

1996-10-01T23:59:59.000Z

86

High-voltage supply for backward-wave tube  

SciTech Connect (OSTI)

A high-current high-voltage supply for a backward-wave tube is described that uses a generalppurpose semiconductor converter with pulse-width modulation and two-stage regulation. The load current is up to 250 mA for load voltages of from 0.5 to 4.5 kV. The voltage staiblity is less than or equal to 5 x 10/sup -6/. the root-mean-square output ripple is less than or equal to 2 x 10/sup -6// The supply is equipped with high-speed (5 usec) load-breakdown protection.

Bryvkhanov, A.N.; Kosarev, P.M.; Latushkin, S.T.; Yudin, L.I.

1986-04-01T23:59:59.000Z

87

HEMP-induced transients in electric power substations. Final report  

SciTech Connect (OSTI)

A nuclear detonation in or above the earth`s atmosphere produces an intense electromagnetic pulse (EMP). A large portion of the EMP electromagnetic energy is within the RF spectrum. A detonation at high altitudes above 40 km produces an EMP called high-altitude EMP (HEMP). HEMP is a steep-front short duration transient with a rise time on the order of a few nanoseconds which decays to near zero in less than a microsecond. A single high-altitude burst can subject much of the continental United States to intense HEMP electric fields on the order of tens of kilovolts per meter. The intense transient HEMP will induce fast transients in high-voltage transmission lines and bus structures, instrumentation cables, and control wires in power transmission and distribution (T & D) substations. A system of traveling wave coupling models for a 500 kV substation, including models for the high voltage primary bus, components (circuit breakers, disconnect switches, power transformers, and current and voltage instrument transformers), low voltage control wiring circuits, and a number of conducted and radiated interference coupling modes, had been developed earlier by EPRI. These EPRI served as the baseline for the present HEMP coupling investigations. The HEMP effects on protective relays were assessed for a nominal HEMP environment using several new field coupling models merged with the switching transient data. It is found that a representative solid state relay is unlikely to be damaged or to misoperate by the nominal HEMP threat with a peak field strength of 50 kV/m. However, it is possible for both DC control wires to flash over to ground simultaneously, causing fuses to blow and placing the relay in an inoperative state.

Wiggins, C.M.; Thomas, D.E.; Salas, T.M. [BDM International, Inc., Albuquerque, NM (United States)

1992-02-01T23:59:59.000Z

88

HEMP-induced transients in electric power substations  

SciTech Connect (OSTI)

A nuclear detonation in or above the earth's atmosphere produces an intense electromagnetic pulse (EMP). A large portion of the EMP electromagnetic energy is within the RF spectrum. A detonation at high altitudes above 40 km produces an EMP called high-altitude EMP (HEMP). HEMP is a steep-front short duration transient with a rise time on the order of a few nanoseconds which decays to near zero in less than a microsecond. A single high-altitude burst can subject much of the continental United States to intense HEMP electric fields on the order of tens of kilovolts per meter. The intense transient HEMP will induce fast transients in high-voltage transmission lines and bus structures, instrumentation cables, and control wires in power transmission and distribution (T D) substations. A system of traveling wave coupling models for a 500 kV substation, including models for the high voltage primary bus, components (circuit breakers, disconnect switches, power transformers, and current and voltage instrument transformers), low voltage control wiring circuits, and a number of conducted and radiated interference coupling modes, had been developed earlier by EPRI. These EPRI served as the baseline for the present HEMP coupling investigations. The HEMP effects on protective relays were assessed for a nominal HEMP environment using several new field coupling models merged with the switching transient data. It is found that a representative solid state relay is unlikely to be damaged or to misoperate by the nominal HEMP threat with a peak field strength of 50 kV/m. However, it is possible for both DC control wires to flash over to ground simultaneously, causing fuses to blow and placing the relay in an inoperative state.

Wiggins, C.M.; Thomas, D.E.; Salas, T.M. (BDM International, Inc., Albuquerque, NM (United States))

1992-02-01T23:59:59.000Z

89

Substation grounding programs  

SciTech Connect (OSTI)

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. This report, Volume 5, is an applications guide of the three computer programs. SOMIP, SMECC, and SGSYS, for the purpose of designing a safe substation grounding system. The applications guide utilizes four example substation grounding systems for the purpose of illustrating the application of the programs, SOMIP, SMECC, and SGSYS. The examples are based on data provided by four contributing utilities, namely, Houston Lighting and Power Company, Southern Company Services, Puget Sound Power and Light Company, and Arizona Public Service Company. For the purpose of illustrating specific capabilities of the computer programs, the data have been modified. As a result, the final designs of the four systems do not necessarily represent actual grounding system designs by these utilities. The example system 1 is a 138 kV/35 kV distribution substation. The example system 2 is a medium size 230 kV/115 kV transmission substation. The third example system is a generation substation while the last is a large 525 kV/345 kV/230 kV transmission substation. The four examples cover most of the practical problems that a user may encounter in the design of substation grounding systems.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

90

High Voltage Electrolytes for Li-ion Batteries | Department of...  

Broader source: Energy.gov (indexed) [DOE]

Electrolytes for Li-ion Batteries High Voltage Electrolytes for Li-ion Batteries 2011 DOE Hydrogen and Fuel Cells Program, and Vehicle Technologies Program Annual Merit Review and...

91

High Voltage Electrolytes for Li-ion Batteries | Department of...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

in Support of 5 V Li-ion Chemistries Vehicle Technologies Office Merit Review 2014: Fluorinated Electrolyte for 5-V Li-Ion Chemistry High Voltage Electrolyte for Lithium Batteries...

92

High voltage dry-type air-core shunt reactors  

Science Journals Connector (OSTI)

Dry-type air-core shunt reactors are now being ... systems to limit overvoltages. Recently, high voltage dry-type air-core shunt reactors have been designed, ... transient overvoltages and electrical and magnetic...

Klaus Papp; Michael R. Sharp…

2014-11-01T23:59:59.000Z

93

High-speed low-voltage ultraviolet light source  

Science Journals Connector (OSTI)

A novel quasi-spark gap has been designed and constructed with high-speed and low-spark voltage characteristics. Ultraviolet light generating sparks can be operated at a rate of up to...

Huang, L; Hsu, S C; Kwok, H S

1984-01-01T23:59:59.000Z

94

Microsoft Word - CX_Memo_FranklinSubstation.docx  

Broader source: Energy.gov (indexed) [DOE]

Amy Freel Amy Freel Project Manager - TEP-TPP-1 Proposed Action: Franklin Substation Upgrades Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.11 Electrical power substations and interconnection facilities Location: Pasco, Washington Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: The BPA proposes to make improvements to the BPA fee-owned Franklin Substation located in southeastern Washington in order to bring the substation into compliance with BPA's minimum voltage guidelines. A shunt capacitor bank would be installed to provide voltage support. Project activities would include moving a temporary mobile capacitor bank, removing transformers, extending a 115-kilovolt (kV) bus, installing a new 115-kV

95

High voltage electrical amplifier having a short rise time  

DOE Patents [OSTI]

A circuit, comprising an amplifier and a transformer is disclosed that produces a high power pulse having a fast response time, and that responds to a digital control signal applied through a digital-to-analog converter. The present invention is suitable for driving a component such as an electro-optic modulator with a voltage in the kilovolt range. The circuit is stable at high frequencies and during pulse transients, and its impedance matching circuit matches the load impedance with the output impedance. The preferred embodiment comprises an input stage compatible with high-speed semiconductor components for amplifying the voltage of the input control signal, a buffer for isolating the input stage from the output stage; and a plurality of current amplifiers connected to the buffer. Each current amplifier is connected to a field effect transistor (FET), which switches a high voltage power supply to a transformer which then provides an output terminal for driving a load. The transformer comprises a plurality of transmission lines connected to the FETs and the load. The transformer changes the impedance and voltage of the output. The preferred embodiment also comprises a low voltage power supply for biasing the FETs at or near an operational voltage.

Christie, David J. (Pleasanton, CA); Dallum, Gregory E. (Livermore, CA)

1991-01-01T23:59:59.000Z

96

Design & Fabrication of a High-Voltage Photovoltaic Cell  

SciTech Connect (OSTI)

Silicon photovoltaic (PV) cells are alternative energy sources that are important in sustainable power generation. Currently, applications of PV cells are limited by the low output voltage and somewhat low efficiency of such devices. In light of this fact, this project investigates the possibility of fabricating high-voltage PV cells on float-zone silicon wafers having output voltages ranging from 50 V to 2000 V. Three designs with different geometries of diffusion layers were simulated and compared in terms of metal coverage, recombination, built-in potential, and conduction current density. One design was then chosen and optimized to be implemented in the final device design. The results of the simulation serve as a feasibility test for the design concept and provide supportive evidence of the effectiveness of silicon PV cells as high-voltage power supplies.

Felder, Jennifer; /North Carolina State U. /SLAC

2012-09-05T23:59:59.000Z

97

High Temperature, High Voltage Fully Integrated Gate Driver Circuit  

Broader source: Energy.gov (indexed) [DOE]

driver circuit, 5-V on- chip voltage regulator, short-circuit protection, undervoltage lockout, bootstrap capacitor, dead time controller and temperature sensor * 0.8-micron,...

98

Design issues for high voltage converters for ion engines  

SciTech Connect (OSTI)

A design strategy is presented for a power converter for a high voltage ion engine for a spacecraft application. Various design issues such as appropriate topologies and control methods are considered. In this particular instance it was determined that a full bridge converter with phase shift gating and voltage mode control provided an efficient system with a minimum of electromagnetic interference. This system can be implemented in a straightforward manner, and it is relatively easy to protect from faults at the output.

King, R.J.; Stuart, T.A. [Univ. of Toledo, OH (United States)

1995-12-31T23:59:59.000Z

99

Polymerizable Additive for Passivating High Voltage Cathodes  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

batteries with the goal of significantly increasing battery energy density. Conventional Li-ion battery electrolyte systems are quite unstable at these high potentials, leading to...

100

Modeling and Simulating Blast Effects on Electric Substations  

SciTech Connect (OSTI)

A software simulation tool was developed at the Idaho National Laboratory to estimate the fragility of electric substation components subject to an explosive blast. Damage caused by explosively driven fragments on a generic electric substation was estimated by using a ray-tracing technique to track and tabulate fragment impacts and penetrations of substation components. This technique is based on methods used for assessing vulnerability of military aircraft and ground vehicles to explosive blasts. An open-source rendering and ray-trace engine was used for geometric modeling and interactions between fragments and substation components. Semi-empirical material interactions models were used to calculate blast parameters and simulate high-velocity material interactions between explosively driven fragments and substation components. Finally, a Monte Carlo simulation was added to model the random nature of fragment generation allowing a skilled analyst to predict failure probabilities of substation components.

Lyle G. Roybal; Robert F. Jeffers; Kent E. McGillivary; Tony D. Paul; Ryan Jacobson

2009-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360{degree}/n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load. 7 figs.

Shimer, D.W.; Lange, A.C.

1997-03-11T23:59:59.000Z

102

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1997-01-01T23:59:59.000Z

103

Experiment Hazard Class 13.0 - High Voltage  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3.0 - High Voltage 3.0 - High Voltage Applicability This hazard classification applies to all experiments involving the use of High Voltage Equipment. Other hazard classifications and their associated hazard controls may also apply to experiments in this hazard class. The inspection of electric equipment is covered under the APS Policy For User Electric Equipment Inspections. NOTE: Unless required Argonne training has been completed, users are not authorized to perform electrical work. Experiment Category All Hazard Class 13 experiments are categorized as medium risk experiments. Experiment Hazard Control Verification Statements Engineered Controls - Determined by review and results of a DEEI inspection of the equipment. Procedural Controls - Determined by review and results of a DEEI

104

High voltage stability performance of a gamma ray detection device  

SciTech Connect (OSTI)

An industrial grade digital radiation survey meter device is currently being developed at Malaysian Nuclear Agency. This device used a cylindrical type Geiger Mueller (GM) which acts as a detector. GM detector operates at relatively high direct current voltages depend on the type of GM tube. This thin/thick walled cylindrical type of GM tube operates at 450-650 volts range. Proper value and stability performance of high voltage are important parameters to ensure that this device give a reliable radiation dose measurement. This paper will present an assessment of the stability and performance of the high voltage supply for radiation detector. The assessment is performed using System Identification tools box in MATLAB and mathematical statistics.

Abdullah, Nor Arymaswati; Lombigit, Lojius; Rahman, Nur Aira Abd [Technical Support Division, Malaysian Nuclear Agency, 43000 Kajang, Selangor (Malaysia)

2014-02-12T23:59:59.000Z

105

Substation automation problems and possibilities  

SciTech Connect (OSTI)

The evolutionary growth in the use and application of microprocessors in substations has brought the industry to the point of considering integrated substation protection, control, and monitoring systems. An integrated system holds the promise of greatly reducing the design, documentation, and implementation cost for the substation control, protection, and monitoring systems. This article examines the technical development path and the present implementation problems.

Smith, H.L.

1996-10-01T23:59:59.000Z

106

A Radiofrequency High-Voltage Generator  

Science Journals Connector (OSTI)

A large radio oscillator with unrectified alternating anode power-supply sends high-frequency power into a 50 meter wave-length antenna which is coiled up without insulation, and enclosed in a metal vacuum tank. Over 800,000 volts is generated inside of the tank exactly where it is to be used for x-rays or for accelerating ions. There is no insulation to become punctured. Single tuned-circuit resonance transformers are superior to coupled tuned-circuit Tesla coils. Resonance transformers, oscillator circuits, power tubes, power supply and coil construction are described. X-ray production, and ion acceleration are outlined.

David H. Sloan

1935-01-01T23:59:59.000Z

107

Self-Excited ac High Voltage Generation Using Water Droplets  

Science Journals Connector (OSTI)

By letting water drops fall through rings into cans high voltage can be spontaneously generated with no external electrical excitation. Previous work concerning this type of electric influence machine for dc and three-phase ac high voltage generation is extended to include multiphase multifrequency operation by considering N streams and N cans. A distributed equivalent circuit representation is used to calculate the natural frequencies of the system where it is found that many overstable modes are present. Experimental observations with up to five cans are presented. This device can serve as a model for phenomena concerned with atmospheric electricity.

Markus Zahn

1973-01-01T23:59:59.000Z

108

Substation asset management study  

SciTech Connect (OSTI)

This paper will present an overview of our recent findings in the area of substation asset management and will describe how several utilities, in response to the issues listed above, are re-examining their present maintenance practices in search of more cost-effective programs.

Conroy, M.W.; Conidi, J. [Sargent & Lundy, Chicago, IL (United States)

1996-03-01T23:59:59.000Z

109

Summaries of Addresses of Presidents of Sections: High-Voltage Insulation  

Science Journals Connector (OSTI)

... subject of his presidential address to Section A (Mathematics and Physics) *'High-voltage Insulation".

1963-08-31T23:59:59.000Z

110

Current isolating epitaxial buffer layers for high voltage photodiode array  

DOE Patents [OSTI]

An array of photodiodes in series on a common semi-insulating substrate has a non-conductive buffer layer between the photodiodes and the semi-insulating substrate. The buffer layer reduces current injection leakage between the photodiodes of the array and allows optical energy to be converted to high voltage electrical energy.

Morse, Jeffrey D. (Martinez, CA); Cooper, Gregory A. (Pleasant Hill, CA)

2002-01-01T23:59:59.000Z

111

Field Optimization of Three Dimensional High Voltage C. Trinitis  

E-Print Network [OSTI]

Field Optimization of Three Dimensional High Voltage Equipment C. Trinitis Lehrstuhl f The goal of finding an optimal electric field strength distribution for arbitrary three di­ mensional­ cal optimization algorithm. The package ob­ tained from these three components is then able

Stamatakis, Alexandros

112

High voltage gas insulated transmission line with continuous particle trapping  

DOE Patents [OSTI]

This invention provides a novel high voltage gas insulated transmission line utilizing insulating supports spaced at intervals with snap-in means for supporting a continuous trapping apparatus and said trapping apparatus having perforations and cutouts to facilitate trapping of contaminating particles and system flexibility.

Cookson, Alan H. (Pittsburgh, PA); Dale, Steinar J. (Monroeville, PA)

1983-01-01T23:59:59.000Z

113

High Voltage DC Transmission 2 1.0 Introduction  

E-Print Network [OSTI]

1 High Voltage DC Transmission 2 1.0 Introduction Interconnecting HVDC within an AC system requires on use of switching devices collectively referred to in the HVDC community as valves. Valves may be non. Fig. 1 There have been three types of devices for implementing HVDC converter circuits: mercury

McCalley, James D.

114

Microsoft Word - CX -Ostrander Substation Expansion.doc  

Broader source: Energy.gov (indexed) [DOE]

6, 2011 6, 2011 REPLY TO ATTN OF: KEC-4 SUBJECT: Environmental Clearance Memorandum Amit Sinha Project Manager - TEP-CSB-2 Proposed Action: Ostrander Substation Addition Budget Information: Work order 00262568 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.11 Construction of electric power substations (including switching stations and support facilities)....or modification (other than voltage increases) of existing substations and support facilities... Location: Clackamas County, Oregon (T2S, R3E, Sections 26 and 35) Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA is proposing to expand its existing Ostrander Substation near Barton, Oregon by approximately 4 acres. The expansion would accommodate three new 230/500-kV transformers,

115

Assessment of occupational exposure to magnetic fields in high-voltage substations (154/34.5 kV)  

Science Journals Connector (OSTI)

......workers on lines and cables and 0.2-18.48 microT for electricians(1,2). At the moment, it can be mentioned that ICNIRP...H., Iskender M. F. Radio Frequency Radiation Dosimetry Handbook. (1986) fourth edn. TX: Brooks Air Force Base, School......

S. Helhel; S. Ozen

2008-03-01T23:59:59.000Z

116

ESS 2012 Peer Review - Low Cost, Manufacturable High Voltage...  

Broader source: Energy.gov (indexed) [DOE]

11 kV 600 kW ESS 6 Comparison of solutions for a 13.8 kV 480 V 100 kVA substation transformer 2 S. Bhattacharya, "15kV SiC IGBT Modules for Grid Scale Power Conversion",...

117

Graz University of Technology Institute of High Voltage Engineering and System Performance  

E-Print Network [OSTI]

.hspt@tugraz.at u www.hspt.tugraz.at Institute of High Voltage Engineering and System Performance Test Laboratory systems Test of insulators, fittings and accessories Testing of high voltage equipment Impulse voltage and current tests On-site-test of medium voltage cables Electrical methods in environmental technology

118

High voltage dc--dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.

Shimer, D.W.; Lange, A.C.

1995-05-23T23:59:59.000Z

119

High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1995-01-01T23:59:59.000Z

120

Automatic Voltage Control of Electrical Systems  

Science Journals Connector (OSTI)

... to have complete automatic voltage regulation and it also has supervisory control for its main substations. By a careful application of automatically controlled regulators it is shown that the voltage ...

1934-01-20T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Cutting costs through substation ownership  

SciTech Connect (OSTI)

The term applied to service through a customer-owned main substation is primary service, and such customers are billed at primary metering rates. These terms denote that the customer accepts service (and billing metering is located) on the primary, rather than secondary, side of the main transformer. Some electric utilities are prepared to offer extremely attractive billing reductions to those customers willing to invest in their own main substations instead of renting a substation purchased with utility company capital. Depending on the utility and the particular circumstances, some plants can recover their investment in primary substation equipment in as little as 1 or 2 years.

Keithly, D. (ABB Electric, Waukesba, WI (US))

1989-06-22T23:59:59.000Z

122

Advanced Gate Drive for the SNS High Voltage Converter Modulator  

SciTech Connect (OSTI)

SLAC National Accelerator Laboratory is developing a next generation H-bridge switch plate [1], a critical component of the SNS High Voltage Converter Modulator [2]. As part of that effort, a new IGBT gate driver has been developed. The drivers are an integral part of the switch plate, which are essential to ensuring fault-tolerant, high-performance operation of the modulator. The redesigned driver improves upon the existing gate drive in several ways. The new gate driver has improved fault detection and suppression capabilities; suppression of shoot-through and over-voltage conditions, monitoring of dI/dt and Vce(sat) for fast over-current detection and suppression, and redundant power isolation are some of the added features. In addition, triggering insertion delay is reduced by a factor of four compared to the existing driver. This paper details the design and performance of the new IGBT gate driver. A simplified schematic and description of the construction are included. The operation of the fast over-current detection circuits, active IGBT over-voltage protection circuit, shoot-through prevention circuitry, and control power isolation breakdown detection circuit are discussed.

Nguyen, M.N.; Burkhart, C.; Kemp, M.A.; /SLAC; Anderson, D.E.; /Oak Ridge

2009-05-07T23:59:59.000Z

123

Fiber optic current monitor for high-voltage applications  

DOE Patents [OSTI]

A current monitor which derives its power from the conductor being measured for bidirectionally measuring the magnitude of current (from DC to above 50 khz) flowing through a conductor across which a relatively high level DC voltage is applied, includes a pair of identical transmitter modules connected in opposite polarity to one another in series with the conductor being monitored, for producing from one module a first light signal having an intensity directly proportional to the magnitude of current flowing in one direction through the conductor during one period of time, and from the other module a second light signal having an intensity directly proportional to the magnitude of current flowing in the opposite direction through the conductor during another period of time, and a receiver located in a safe area remote from the high voltage area for receiving the first and second light signals, and converting the same to first and second voltage signals having levels indicative of the magnitude of current being measured at a given time.

Renda, George F. (Plainsboro, NJ)

1992-01-01T23:59:59.000Z

124

Saving Megawatts with Voltage Optimization  

E-Print Network [OSTI]

that had been installed at several electric utility distribution substations in the U.S. and Canada. These systems, being operated in Conservation Voltage Regulation mode, have provided significant energy conservation where they have been installed...

Wilson, T.; Bell, D.

2010-01-01T23:59:59.000Z

125

High Power, High Voltage FETs in Linear Applications: A User's Perspective  

SciTech Connect (OSTI)

The specifications of the current crop of highpower, high-voltage field-effect transistors (FETs) can lure a designer into employing them in high-voltage DC equipment. Devices with extremely low on-resistance and very high power ratings are available from several manufacturers. However, our experience shows that high-voltage, linear operation of these devices at near-continuous duty can present difficult reliability challenges at stress levels well-below their published specifications. This paper chronicles the design evolution of a 600 volt, 8 ampere shunt regulator for use with megawatt-class radio transmitters, and presents a final design that has met its reliability criteria.

N. Greenough, E. Fredd, S. DePasquale

2009-09-21T23:59:59.000Z

126

Distribution System Voltage Performance Analysis for High-Penetration Photovoltaics  

SciTech Connect (OSTI)

This report examines the performance of commonly used distribution voltage regulation methods under reverse power flow.

Liu, E.; Bebic, J.

2008-02-01T23:59:59.000Z

127

500-kV Central Ferry Substation ...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Central Ferry Substation in Garfield County, Wash., to BPA's 500-kV Lower Monumental Substation in Walla Walla County, Wash. BPA is currently considering two routing...

128

Line Rebuild, Relocation and Substation Projects  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Upgrade Palisades-Goshen Rebuild Wind Projects Line Rebuild, Relocation and Substation Projects BPA has identified several critical rebuild and substation projects...

129

CYBER SECURITY OF SUBSTATION AUTOMATION SYSTEMS .  

E-Print Network [OSTI]

??Cyber intrusions into substations of a power grid are a source of vulnerability since most substations are unmanned and with limited protection of the cyber… (more)

[No author

2014-01-01T23:59:59.000Z

130

Substation automation gains momentum with modern options  

SciTech Connect (OSTI)

This paper discusses issues associated with utility substation automation. Monitoring equipment for monitoring power flow, quality, and harmonics for three substations simultaneously is described.

Beaty, W.

1996-12-01T23:59:59.000Z

131

Substation grounding programs  

SciTech Connect (OSTI)

The five volume report comprises the user manual, installation, and validation manual and an applications guide for the SGA (Substation Grounding Analysis) software package. SGA consists of four computer programs: (1) SOMIP, (2) SMECC, (3) SGSYS, and (4) TGRND. The first three programs provide a comprehensive analysis tool for the design of substation grounding systems to meet safety standards. The fourth program, TGRND, provides a state of the art analysis tool for computing transient ground potential rise and ground system impedance. This part of the report, Volume 1, is a users manual and an installation and validation manual for the computer program SOMIP (SOil Measurement Interpretation Program). This program computes the best estimate of the parameters of a two layer soil model from usual soil resistivity measurements. Four pin or three pin soil measurements can be accommodated. In addition, it provides error bounds on the soil parameters for a given confidence level. The users manual describes data requirements and data preparation procedures. The installation and validation manual describes the computer files which make up the program SOMIP and provides two test cases for validation purposes. 4 refs.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). School of Electrical Engineering)

1992-05-01T23:59:59.000Z

132

High-voltage R-F feedthrough bushing  

DOE Patents [OSTI]

Described is a multi-element, high voltage radio frequency bushing for transmitting rf energy to an antenna located in a vacuum container. The bushing includes a center conductor of complex geometrical shape, an outer coaxial shield conductor, and a thin-walled hollow truncated cone insulator disposed between central and outer conductors. The shape of the center conductor, which includes a reverse curvature portion formed of a radially inwardly directed shoulder and a convex portion, controls the uniformity of the axial surface gradient on the insulator cone. The outer shield has a first substantially cylindrical portion and a second radially inwardly extending truncated cone portion.

Grotz, G.F.

1982-09-03T23:59:59.000Z

133

Self-monitoring high voltage transmission line suspension insulator  

DOE Patents [OSTI]

A high voltage transmission line suspension insulator (18 or 22) which monitors its own dielectric integrity. A dielectric rod (10) has one larger diameter end fitting attachable to a transmission line and another larger diameter end fitting attachable to a support tower. The rod is enclosed in a dielectric tube (14) which is hermetically sealed to the rod's end fittings such that a liquidtight space (20) is formed between the rod and the tube. A pressurized dielectric liquid is placed within that space. A discoloring dye placed within this space is used to detect the loss of the pressurized liquid.

Stemler, Gary E. (Vancouver, WA); Scott, Donald N. (Vancouver, WA)

1981-01-01T23:59:59.000Z

134

Testing of complex IEC 61850 based substation automation systems  

Science Journals Connector (OSTI)

The integration of multifunctional intelligent substation devices (ISDs), in complex substation or power plant automation systems, requires the development of methods and tools for their testing that will ensure the correct operation of protection, control, monitoring, recording and metering functions, under normal and abnormal system conditions. The new IEC 61850 standard for communication networks and systems in substations allows the development of high-speed peer-to-peer communications based distributed applications, based on multicast of status changes or sampled analogue values. This paper details the requirements for the testing of complex substation automation systems. The testing methods need to correspond to the functional hierarchy of the substation automation system. Functional element testing, integration and system testing are discussed. Systems with Substation Bus only, and with both Process Bus and Substation Bus, are considered. A method for the testing of both types of system is proposed, based on a specific order of system components testing. Solutions for the testing of the individual components of the IEC 61850 based system, as well as for the testing of distributed applications, are described at the end of the paper.

Alexander Apostolov

2008-01-01T23:59:59.000Z

135

An Approximate Dynamic Programming Algorithm for the Allocation of High-Voltage Transformer Spares in the  

E-Print Network [OSTI]

An Approximate Dynamic Programming Algorithm for the Allocation of High-Voltage Transformer Spares high-voltage transformer spares throughout the electric grid to mitigate the risk of random transformer-voltage transformers are an integral part of the electric transmission system. A catas- trophic transformer failure

Powell, Warren B.

136

Application and field experience of a digital substation switch  

SciTech Connect (OSTI)

There has been an increase in the use of solid-state, microprocessor-based relays, fault recorders, meters, and programmable controllers; in transmission and distribution substations. These devices can be remotely interrogated or programmed, and can send reports back to a host computer through their RS-232 communications ports. These devices use a wide variety of communications software and protocols. Because these devices can be located in the substation yard, induced surges and voltages can be present on the communication lines. This can impair the ability to communicate over RS-232 lines, and even cause equipment damage. In addition. the distance from the control house to the substation yard can limit the use of standard RS-232 protocol. For greater system economy, several devices must use the same communications channel. This requires a means of reliably connecting several devices to the incoming and outgoing communications circuits. This paper describes a digital substation switch (DSS) that was designed for this application, and its initial installation and field experience at Savannah Electric. The DSS connects various meters, transmission relays, and distribution relays to PCs in remote locations through a voice-grade telephone circuit. In this application, the DSS uses a fiber loop to communicate with the devices in the substation yard.

Spain, R.; Fodero, K.

1994-12-31T23:59:59.000Z

137

Type B Accident Investigation of the Serious Personal Injury while Doble Testing at the Western Area Power Administration Hayden Substation, May 19, 1999  

Broader source: Energy.gov [DOE]

On May 19, 1999, at 10:31 a.m., four Western Area Power Administration (Western) employees were performing Doble testing on a circuit breaker at Hayden Substation in Routt County, Colorado. Three electricians were injured when the high-voltage lead (HVL) of the Doble test set encroached on the minimum approach distance to an energized part outside clearance boundaries, drawing arcing faults.

138

Voltage spike detection in high field superconducting accelerator magnets  

SciTech Connect (OSTI)

A measurement system for the detection of small magnetic flux changes in superconducting magnets, which are due to either mechanical motion of the conductor or flux jump, has been developed at Fermilab. These flux changes are detected as small amplitude, short duration voltage spikes, which are {approx}15mV in magnitude and lasts for {approx}30 {micro}sec. The detection system combines an analog circuit for the signal conditioning of two coil segments and a fast data acquisition system for digitizing the results, performing threshold detection, and storing the resultant data. The design of the spike detection system along with the modeling results and noise analysis will be presented. Data from tests of high field Nb{sub 3}Sn magnets at currents up to {approx}20KA will also be shown.

Orris, D.F.; Carcagno, R.; Feher, S.; Makulski, A.; Pischalnikov, Y.M.; /Fermilab

2004-12-01T23:59:59.000Z

139

Monolithic high voltage nonlinear transmission line fabrication process  

DOE Patents [OSTI]

A process for fabricating sequential inductors and varistor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varistor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process. 6 figs.

Cooper, G.A.

1994-10-04T23:59:59.000Z

140

High-speed, sub-pull-in voltage MEMS switching.  

SciTech Connect (OSTI)

We have proposed and demonstrated MEMS switching devices that take advantage of the dynamic behavior of the MEMS devices to provide lower voltage actuation and higher switching speeds. We have explored the theory behind these switching techniques and have demonstrated these techniques in a range of devices including MEMS micromirror devices and in-plane parallel plate MEMS switches. In both devices we have demonstrated switching speeds under one microsecond which has essentially been a firm limit in MEMS switching. We also developed low-loss silicon waveguide technology and the ability to incorporate high-permittivity dielectric materials with MEMS. The successful development of these technologies have generated a number of new projects and have increased both the MEMS switching and optics capabilities of Sandia National Laboratories.

Spahn, Olga Blum; Brewer, Steven; Olsson, Roy H.; Bogart, Gregory R.; Luck, David L.; Watts, Michael R.; Shaw, Michael J.; Nielson, Gregory N.; Resnick, Paul James; Tigges, Christopher P.; Grossetete, Grant David

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Monolithic high voltage nonlinear transmission line fabrication process  

DOE Patents [OSTI]

A process for fabricating sequential inductors and varactor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varactor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process.

Cooper, Gregory A. (346 Primrose Dr., Pleasant Hill, CA 94523)

1994-01-01T23:59:59.000Z

142

Summary of multiterminal high-voltage direct current transmission technology  

SciTech Connect (OSTI)

This report summarizes the present state of multiterminal (MT) high-voltage direct current (HVDC) power transmission. The purpose is to reassess the need for HVDC circuit breakers and to identify needed research for MT HVDC. The fundamentals of this technology are presented, and previous research and development is reviewed. Although no MT HVDC systems have yet been built, many concepts have been proposed. Some require a dc breaker, and others do not. Both options have advantages and disadvantages for various applications, so the selection will depend on the proposed application. Research is needed to define operating characteristics of various MT HVDC systems. In some applications, dc breakers will be useful, so research into HVDC interruption should continue. Also, dc fault detection and control algorithms for MT systems should be studied.

Biggs, R.B.; Jewell, W.T.

1984-05-01T23:59:59.000Z

143

High-voltage supply for neutron tubes in well-logging applications  

DOE Patents [OSTI]

A high voltage supply is provided for a neutron tube used in well logging. The biased pulse supply of the invention combines DC and full pulse techniques and produces a target voltage comprising a substantial negative DC bias component on which is superimposed a pulse whose negative peak provides the desired negative voltage level for the neutron tube. The target voltage is preferably generated using voltage doubling techniques and employing a voltage source which generates bipolar pulse pairs having an amplitude corresponding to the DC bias level.

Humphreys, D.R.

1982-09-15T23:59:59.000Z

144

Electric power substation capital costs  

SciTech Connect (OSTI)

The displacement or deferral of substation equipment is a key benefit associated with several technologies that are being developed with the support of the US Department of Energy`s Office of Utility Technologies. This could occur, for example, as a result of installing a distributed generating resource within an electricity distribution system. The objective of this study was to develop a model for preparing preliminary estimates of substation capital costs based on rudimentary conceptual design information. The model is intended to be used by energy systems analysts who need ``ballpark`` substation cost estimates to help establish the value of advanced utility technologies that result in the deferral or displacement of substation equipment. This cost-estimating model requires only minimal inputs. More detailed cost-estimating approaches are recommended when more detailed design information is available. The model was developed by collecting and evaluating approximately 20 sets of substation design and cost data from about 10 US sources, including federal power marketing agencies and private and public electric utilities. The model is principally based on data provided by one of these sources. Estimates prepared with the model were compared with estimated and actual costs for the data sets received from the other utilities. In general, good agreement (for conceptual level estimating) was found between estimates prepared with the cost-estimating model and those prepared by the individual utilities. Thus, the model was judged to be adequate for making preliminary estimates of typical substation costs for US utilities.

Dagle, J.E.; Brown, D.R.

1997-12-01T23:59:59.000Z

145

Scoping study: Substation design workstation  

SciTech Connect (OSTI)

This project conducted a survey, consisting of a written questionaire, a workshop, and site visits to determine what facets of substation engineering would benefit from incorporation into a workstation environment. Based on the needs expressed by the respondents, a program for the staged development of a Substation Workstation is recommended. Six analytical function modules for assisting in substation engineering were identified for potential inclusion in the workstation: Initial Planning Activities; Physical Plant Design; Analytical Functions; Civil/Structural Design; Environmental Design; and Project Management. The initial release of the Substation Workstation is recommended to include the workstation environment (including MENTOR -- a concept for on-line help, tutorials, notepad, a minor spreadsheet, and interfaces to other regular desktop functions) and portions of the first three functional modules listed above. Recommendations for progress beyond this first release of the workstation included the development of additional capabilities within the initial functional modules, as well as the development of the remaining modules. An overlap exists between the analytical requirements for this workstation and those already included in the EPRI TLWorkstation and the ICWorkstation. In some cases, elements of these other workstations are also suggested for incorporation into the Substation Workstation (such as the foundation analyses from the TLWorkstation), and in others, an assimilation of the other workstation into the Substation Workstation is recommended (as with the ICWorkstation). Estimated resources for implementing the recommended program, including both costs and development time, are also provided.

Mauser, S.F. (Power Technologies, Inc., Wilmerding, PA (United States)); Conroy, M.W. (Sargent and Lundy, Chicago, IL (United States)); Singh, N.M. (Power Computing, Dallas, TX (United States))

1993-03-01T23:59:59.000Z

146

Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power Filter Applications  

E-Print Network [OSTI]

Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power voltage-source inverters connected in series (known as cascaded hybrid asymmetric multilevel inverter voltage application due to semiconductor constraint. In order to achieve higher power level, hybrid

Catholic University of Chile (Universidad CatĂłlica de Chile)

147

Substation grounding programs  

SciTech Connect (OSTI)

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. It can be used to compute transient ground potential rise due to lightning or switching, and the ground impedance (i.e. resistance and reactance) at specified frequencies. This report, Volume 4, is a users manual and an installation and validation manual for the computer program TGRND (Transient GRouNDing System Analysis Program). This program computes transient ground potential rise resulting from lightning, switching, or other transient electric currents injected to a grounding system. The program also computes the impedance (i.e. resistance and reactance) of a grounding system as a function of frequency. This program can be utilized in an interactive or batch mode. The users manual describes data requirements and data preparation procedures. The installation and validation manual describes the computer files which make up the program TGRND and provides a test case for validation purposes.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

148

Radio-Frequency Interference (RFI) From Extra-High-Voltage (EHV) Transmission Lines  

E-Print Network [OSTI]

discharges are a design issue. Extra-high-voltage (EHV) transmission lines have operating voltages of 345 kV building a 345-kV transmission line from Red Hill, NM to Deming, NM which would run east along US60 to its with respect to radio noise: (1) lines with voltages below 70 kV and (2) lines with voltages above 110 kV

Ellingson, Steven W.

149

Control of Analyte Electrolysis in Electrospray Ionization Mass Spectrometry Using Repetitively Pulsed High Voltage  

SciTech Connect (OSTI)

Analyte electrolysis using a repetitively pulsed high voltage ion source was investigated and compared to that using a regular, continuously operating direct current high voltage ion source in electrospray ionization mass spectrometry. The extent of analyte electrolysis was explored as a function of the length and frequency of the high voltage pulse using the model compound reserpine in positive ion mode. Using +5 kV as the maximum high voltage amplitude, reserpine was oxidized to its 2, 4, 6 and 8-electron oxidation products when direct current high voltage was employed. In contrast, when using a pulsed high voltage, oxidation of reserpine was eliminated by employing the appropriate high voltage pulse length and frequency. This effect was caused by inefficient mass transport of the analyte to the electrode surface during the duration of the high voltage pulse and the subsequent relaxation of the emitter electrode/ electrolyte interface during the time period when the high voltage was turned off. This mode of ESI source operation allows for analyte electrolysis to be quickly and simply switched on or off electronically via a change in voltage pulse variables.

Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

2011-01-01T23:59:59.000Z

150

Characterization of ferroresonant modes in HV substation with CB grading capacitors  

Science Journals Connector (OSTI)

This paper reports a ferroresonant experience involving inductive voltage transformers (VT's) in a 400 kV substation equipped with circuit breaker grading capacitors. Field measurements are presented and compared with ATP/EMTP simulation results, showing very good agreement. A parametric analysis has been performed to investigate the effect of the substation capacitance on the occurrence of ferroresonance. Fundamental frequency and sub-harmonic ferroresonant modes have been identified and compiled in a bifurcation diagram. The methodology presented can be used to create risk maps of avoidable switching operations or substation configurations.

M. Val Escudero; I. Dudurych; M.A. Redfern

2007-01-01T23:59:59.000Z

151

High voltage power supply with modular series resonant inverters  

DOE Patents [OSTI]

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360.degree./n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit.

Dreifuerst, Gary R. (Livermore, CA); Merritt, Bernard T. (Livermore, CA)

1995-01-01T23:59:59.000Z

152

High voltage power supply with modular series resonant inverters  

DOE Patents [OSTI]

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360{degree}/n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit. 11 figs.

Dreifuerst, G.R.; Merritt, B.T.

1995-07-18T23:59:59.000Z

153

Theory and practice of dynamic voltage/frequency scaling in the high performance computing environment.  

E-Print Network [OSTI]

?? This dissertation provides a comprehensive overview of the theory and practice of Dynamic Voltage/Frequency Scaling (DVFS) in the High Performance Computing (HPC) environment. We… (more)

Rountree, Barry Louis

2010-01-01T23:59:59.000Z

154

Automotive high-voltage electrical system with integrated safeguard  

Science Journals Connector (OSTI)

For several years the use of higher system voltages has been a topic in the automotive industry. Whether for hybrid or conventional vehicles, safeguards are required which protect both the vehicle...

Thomas Flottmann

2007-03-01T23:59:59.000Z

155

Ashland Area Support Substation Project  

SciTech Connect (OSTI)

The Bonneville Power Administration (BPA) provides wholesale electric service to the City of Ashland (the City) by transferring power over Pacific Power Light Company's (PP L) 115-kilovolt (kV) transmission lines and through PP L's Ashland and Oak Knoll Substations. The City distributes power over a 12.5-kV system which is heavily loaded during winter peak periods and which has reached the limit of its ability to serve peak loads in a reliable manner. Peak loads under normal winter conditions have exceeded the ratings of the transformers at both the Ashland and Oak Knoll Substations. In 1989, the City modified its distribution system at the request of PP L to allow transfer of three megawatts (MW's) of electric power from the overloaded Ashland Substation to the Oak Knoll Substation. In cooperation with PP L, BPA installed a temporary 6-8 megavolt-amp (MVA) 115-12.5-kV transformer for this purpose. This additional transformer, however, is only a temporary remedy. BPA needs to provide additional, reliable long-term service to the Ashland area through additional transformation in order to keep similar power failures from occurring during upcoming winters in the Ashland area. The temporary installation of another 20-MVA mobile transformer at the Ashland Substation and additional load curtailment are currently being studied to provide for sustained electrical service by the peak winter period 1992. Two overall electrical plans-of-service are described and evaluated in this report. One of them is proposed for action. Within that proposed plan-of-service are location options for the substation. Note that descriptions of actions that may be taken by the City of Ashland are based on information provided by them.

Not Available

1992-06-01T23:59:59.000Z

156

Microcomputer Applications in Power System Substation Automation  

Science Journals Connector (OSTI)

The object of this chapter is to describe power system applications of microcomputers, particularly in the area of power substation automation.The major functions required in substation automation are reviewed an...

C. T. Nguyen; R. Grondin; A. St-Jacques…

1983-01-01T23:59:59.000Z

157

Radio-frequency powered glow discharge device and method with high voltage interface  

DOE Patents [OSTI]

A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components. 11 figures.

Duckworth, D.C.; Marcus, R.K.; Donohue, D.L.; Lewis, T.A.

1994-06-28T23:59:59.000Z

158

Classification of sags gathered in distribution substations based on multiway principal component analysis  

Science Journals Connector (OSTI)

Voltage sags, whether they occur in transmission or distribution systems, may severely damage the loads connected to the power system. As these problems could cost a great deal financially, electric utilities are very interested in finding the origins of sags, that is, whether they have been originated in the transmission network (high voltage (HV)) or in the distribution system (medium voltage (MV)). In addition to the needs of utilities and regulators, many researchers have been prompted to develop reliable methods to properly classify sags. Several of these methods, based on classifying meaningful features extracted from data and waveforms, have been proposed in the literature. Unlike those methods, though, we propose a systematic transformation of data, based on multiway principal component analysis (MPCA), to develop a new voltage sag classification procedure. Sampled voltage and current waveforms of previously registered sags are used together with the MPCA technique to obtain a lower dimensional model. This model is then used to project new sags and classify them according to their origin in the power system. Different classification criteria and parameters are examined to maximize the classification rates of not yet seen sags. Applying the proposed method to real sags recorded in substations demonstrates its applicability and power.

Abbas Khosravi; Joaquim Meléndez; Joan Colomer

2009-01-01T23:59:59.000Z

159

Proceedings: Tenth EPRI Substation Equipment Diagnostics Conference  

SciTech Connect (OSTI)

Advanced monitoring and diagnostic sensors and systems are needed to provide reliable and accurate information for determining the condition of major transmission substation equipment. The tenth EPRI Substation Equipment Diagnostics Conference highlighted the work of researchers, universities, manufacturers, and utilities in producing advanced monitoring and diagnostic equipment for substations.

None

2002-06-01T23:59:59.000Z

160

Proceedings: Substation Equipment Diagnostics Conference IX  

SciTech Connect (OSTI)

Advanced monitoring and diagnostic sensors and systems are needed to provide reliable and accurate information for determining the condition of major transmission substation equipment. The ninth EPRI Substation Equipment Diagnostics Conference highlighted the work of researchers, universities, manufacturers, and utilities in producing advanced monitoring and diagnostic equipment for substations.

None

2001-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Proceedings: Substation Equipment Diagnostics Conference VIII  

SciTech Connect (OSTI)

Advanced monitoring and diagnostic sensors and systems are needed to provide reliable and accurate information for determining the condition of major transmission substation equipment. The eighth EPRI Substation Equipment Diagnostics Conference highlighted the work of researchers, universities, manufacturers, and utilities in producing advanced monitoring and diagnostic equipment for substations.

None

2000-06-01T23:59:59.000Z

162

Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions  

E-Print Network [OSTI]

Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 19-1 High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 1. DC Properties of Modern Filled Epoxy Insulation Academic and Research Staff Dr. Chathan Cooke Sponsor

163

Evaluation of Insulation Systems for the Optimal Design of High Voltage Pulse Transformers  

E-Print Network [OSTI]

This paper presents a study for the design of the insulation systems of high voltage pulse transformer based on experimental tests and numerical simulations. Data of high voltage tests on solid and liquid insulation materials are presented and discussed. The understanding of each part of the insulation is supported by electrostatic fields simulations.

Sylvain, Candolfi; Davide, Aguglia; Philippe, Viarouge; Jürgen, Biela; Jerome, Cros

2015-01-01T23:59:59.000Z

164

High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report | Open  

Open Energy Info (EERE)

High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report Jump to: navigation, search Tool Summary LAUNCH TOOL Name: High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report Focus Area: Crosscutting Topics: Policy Impacts Website: www.netl.doe.gov/smartgrid/referenceshelf/reports/HV-BPL_Final_Report. Equivalent URI: cleanenergysolutions.org/content/high-voltage-broadband-over-powerline Language: English Policies: "Deployment Programs,Financial Incentives" is not in the list of possible values (Deployment Programs, Financial Incentives, Regulations) for this property. DeploymentPrograms: Technical Assistance This reports details findings from a pilot High Voltage Broadband over Power Line (HV-BPL) program, an effort to develop a disruptive technology

165

Structure, Vol. 10, 5160, January, 2002, 2002 Elsevier Science Ltd. All rights reserved. PII S0969-2126(01)00699-2 Probing Substates in Sperm Whale Myoglobin  

E-Print Network [OSTI]

-2126(01)00699-2 Probing Substates in Sperm Whale Myoglobin Using High-Pressure Crystallography that protein crystals do in the populations of conforma- tional substates. Furthermore, a novel high-pressure temperatures. Unlike in flash in the conformation of groups of atoms may be described by a simple isotropic expansion or com-mational substates

Phillips, George N. Jr.

166

East Grangeville Substation : Environmental Assessment.  

SciTech Connect (OSTI)

BPA proposes to build a 6/8 MVA, 115/13.8-kV substation about 0.7 mile (1.2 km) east of Grangeville, Idaho. BPA's substation yard would comprise an area of 70 by 72 feet (21 by 22 m) containing a 115/13.8-kV transformer. Energization for the substation is scheduled for September 1983. In connected actions the Co-op would build a 13.8-kV switching station and a 13.8/34.5-kV step-up station. The Co-op would require an area of 100 by 55 feet (31 by 17 m) in addition to the BPA yard. The total area needed for the combined BPA/Co-op substation would be approximately 170 by 127 feet (52 by 40 m) or one-half of an acre (0.20 ha). The Co-op would also build two 13.8-kV feeders and one 34.5-kV feeder underground south of the substation to overhead distribution lines along State Highway 13 with space for one future feeder. Another 13.8-kV feeder would exit the substation underground and loop around to the north to reconnect to the existing 13.8-kV overhead line. TWWP would build a tapline from their Grangeville-Kamiah-Nez Perce (Grangeville-Nez Perce No. 2) 115-kV transmission line to the substation. This line would be approximately 0.75 mile (1.2 km) long and would consist of single wood pole structures built on the route of an existing Co-op distribution line. The new and existing lines would use the same poles. A temporary access road would be built for 0.25 mile (0.4 km). The remaining 0.5 mile (0.8 km) section would be adjacent to a county road and would not require an access road. Two sites were identified as meeting the technical requirements. Site 2 is recommended.

United States. Bonneville Power Administration.

1983-03-01T23:59:59.000Z

167

MOV surge arresters: improved substation equipment protection  

SciTech Connect (OSTI)

The introduction of metal-oxide-varistor (MOV) surge arresters has added a new dimension to substation equipment protection. Through the optimal use of these arresters, it is possible to lower surge arrester ratings and thereby improve protective margins, resulting in a possible reduction of the insulation levels (BIL) of substation equipment. This reduction in BIL can lead to a significant reduction in the cost of substation equipment. General methods are delineated for selecting MOV surge arresters for substation protection and the resulting effect on substation equipment insulation levels.

Niebuhr, W.D.

1985-07-01T23:59:59.000Z

168

Transient performance of substation structures and associated grounding systems  

SciTech Connect (OSTI)

When lightning strikes an electric substation, large currents generated by the stroke flow in the above ground structures and grounding system and dissipate in the soil. The electromagnetic fields generated by such high currents may cause damage to equipment and may be dangerous to personnel working nearby. In this paper, the frequency and time domain performance of a substation subjected to a lightning strike is described and discussed. The computed scalar potentials, electric fields, and magnetic fields are presented graphically as a function of spatial coordinates, as a function of time and as a function of both. Two cases are considered. The first case examines the substation grounding system only, while the second case includes an above-ground structure as well. It is believed that the results of the second case have not been published before. A double exponential lightning surge current is injected at one corner of the substation. The response of the grounding system to the frequency domain electromagnetic spectrum of this signal is computed by a frequency domain electromagnetic field analysis software package. The temporal and spatial distributions of the electromagnetic fields inside and near the substation are obtained by an inverse Fourier transformation of all these responses. The presence of a soil with an arbitrary resistivity and permittivity is accurately taken into account. The analysis sheds some new light on the understanding of the effects which take place at the higher frequencies.

Dawalibi, F.P.; Xiong, W.; Ma, J. [Safe Engineering Services and Technologies Ltd., Montreal, Quebec (Canada)] [Safe Engineering Services and Technologies Ltd., Montreal, Quebec (Canada)

1995-05-01T23:59:59.000Z

169

RECORD OF CATEGORICAL EXCLUSION DETERMINATION Ault Substation Expansion and Equipment Additions, Weld County, CO  

Broader source: Energy.gov (indexed) [DOE]

Ault Substation Expansion and Equipment Additions, Weld County, CO Ault Substation Expansion and Equipment Additions, Weld County, CO A. Proposed Action: Western proposes to expand the existing Ault SUbstation and add electrical equipment. The expansion would be within the existing fee-owned land. B. Number and Title of Categorical Excluison Being Applied . B4.11: Construction of electric power substations (including switching stations and support facilities) with power deliver at 230-kV or below, or modification (other than voltage increases) of existing sutstations and support facilities .. .. C. Regulatory Requirements in 10 CFR 1021.410(b): (Refer to full text in regulation ). (1) The proposed action fits within a class of actions that is listed in Appendix A or B to Subpart D. For classes of actions, listed in Appendix B, the following conditions are

170

The high voltage problem in the saturated core HTS fault current limiter  

Science Journals Connector (OSTI)

A small model of a one-phase saturated core HTS fault current limiter was developed. It consists of an iron core, an AC coil and a DC HTS coil. The HTS coil comprised six 126 turns double-pancakes (ID 70 mm), wound after heat treatment from Bi-2223 multifilamentary tape in Ag matrix. A fault simulation circuit was set up to characterize the dynamic properties of the model limiter. The voltages and currents of the AC coil and the DC HTS coil were measured through a computer-based data acquisition system. The tests have shown that the limiter has a fast response and the first current peak can be easily limited, but a high voltage will be induced on the DC HTS coil side during the fault state. This high voltage can badly affect the DC current equipment on the DC HTS coil side. The origin and value of the high voltage can be explained using a transformer model. For a limiter with n1 turns AC coil and n2 turns DC coil, the largest induced voltage will be roughly close to (n2/n1)U, where U is the rated voltage of the limiter. To commercialize this kind of limiter, the high voltage problem must be solved. Some different designs were introduced to lower the induced voltage.

Y.F. He; J.H. Li; X.H. Zong; J. Sun; Y.N. Wang; C.L. Wu; J.X. Wang

2003-01-01T23:59:59.000Z

171

Public Opinions of Building Additional High-Voltage Electric Power Lines  

E-Print Network [OSTI]

to build new power lines. Residents living in counties with planned routes for new transmission linesPublic Opinions of Building Additional High-Voltage Electric Power Lines A Report to the National-Voltage Electric Power Lines: A Report to the National Science Foundation and the Electric Power Research Center

Tesfatsion, Leigh

172

Microsoft Word - CX_Memo_MonroeSubstation.docx  

Broader source: Energy.gov (indexed) [DOE]

8, 2013 8, 2013 REPLY TO ATTN OF: KEC-4 SUBJECT: Environmental Clearance Memorandum Amy Freel Project Manager - TEP-TPP-1 Proposed Action: Monroe Substation Integrated Project Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.11 Electrical power substations and interconnection facilities Location: Snohomish County, Washington; Township 28 North, Range 7 East, Section 22 Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: The purpose of the project is to provide upgrades required as part of BPA's ongoing sustaining programs by providing voltage support and preventing power outages. The project would consist of the following activities: ď‚· Installation of two new 500-kilovolt (kV) shunt capacitor groups with current limiting

173

Dynamic sub-transmission substation expansion planning using learning automata  

Science Journals Connector (OSTI)

This paper presents a new method to solve the dynamic sub-transmission substation expansion planning (SSEP) in electric power distribution networks. The method employs a new algorithm based on learning automata for optimization process. The developed algorithm includes different electrical constraints such as voltage drops, thermal limits, power flow and radial flow constraints. Moreover, prevalent cost indices are taken into consideration. The proposed method is used to solve the dynamic SSEP for Birjand city, center of South-Khorasan province of Iran, up to the year 2024. In addition, effects of the dynamic and pseudo-dynamic planning models are investigated at the study region and the obtained results are compared to those of genetic algorithm. Detailed numerical results and comparisons presented in the paper show that the proposed approach leads to proper solutions and can be used as an effective tool for the dynamic sub-transmission substation expansion planning in an actual large scale distribution network.

Seyed Mahdi Mazhari; Hassan Monsef

2013-01-01T23:59:59.000Z

174

Redesign process of a 765 kVRMS AC substation connector by means of 3D-FEM simulations  

Science Journals Connector (OSTI)

Abstract This paper shows the capabilities of applying the three-dimensional finite element method (3D-FEM) for designing complex-shaped substation connectors to operate at 765 kVRMS AC. To check this methodology, it was analyzed the feasibility of upgrading a 400 kVRMS substation connector to operate at 765 kVRMS. However, both experimental and simulation results conducted according to the ANSI/NEMA CC 1-2009 standard concluded that although it passed the visual corona test, to ensure a wide safety margin it was desirable an improvement of the electrical behavior of such connector. It was shown that FEM results allowed detecting the peak stress points of the connector regarding the electrical stress thus allowing applying a corrective action. Then, two possible solutions were analyzed, i.e. the use of corona shields and the redesign of the connector assisted by 3D-FEM simulations. Results presented in this work show that both approaches have an excellent behavior in reducing the electric field strength on the connector surface. However, to make the final decision, the production cost of both alternatives was analyzed, thus favoring the redesign option. Next, the redesigned version of the substation connector was manufactured and tested. Experimental results conducted in a high voltage laboratory verified the effectiveness of the methodology and the potential of the proposed system to act as an advanced design tool for optimizing the behavior of complex-shaped substation connectors. Thus, this system allows assisting efficiently the design process while permitting constraining the economic costs.

Joan Hernández-Guiteras; Jordi-Roger Riba; Luís Romeral

2014-01-01T23:59:59.000Z

175

Seismic base isolation of gas insulated electrical substations: Comparison among different solutions  

SciTech Connect (OSTI)

Base isolation of an outdoor 170 kV Gas-Insulated Substation conforming to ENEL standardization is proposed. The analyzed GIS has two separated phases and its layout consists of a compact block composed of five bays and two High-to-Medium Voltage power transformers. The design has been carried out following the International Electrotechnical Commission (IEC) requirements for seismic qualification of HV equipment. Three solutions are presented, each making use of different isolation devices: High-Damping Steel-Laminated Rubber Bearings, helical springs and visco-dampers, Friction Pendulu devices. The procedures adopted in the design of the three isolation systems are briefly explained, pointing out advantages and drawbacks of each solution.

Serino, G. [Univ. di Napoli Federico II (Italy). Dipt. di Analisi e Progettazione Strutturale; Bettinali, F. [ENEL s.p.a., Milano (Italy). Centro di Ricerca Idraulica e Strutturale; Bonacina, G. [ISMES s.p.a., Seriate (Italy). Div. Indagini Strutturali

1995-12-31T23:59:59.000Z

176

Light-weight DC to very high voltage DC converter  

DOE Patents [OSTI]

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current.

Druce, Robert L. (Union City, CA); Kirbie, Hugh C. (Dublin, CA); Newton, Mark A. (Livermore, CA)

1998-01-01T23:59:59.000Z

177

Light-weight DC to very high voltage DC converter  

DOE Patents [OSTI]

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current. 1 fig.

Druce, R.L.; Kirbie, H.C.; Newton, M.A.

1998-06-30T23:59:59.000Z

178

An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.  

SciTech Connect (OSTI)

References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

Litzenberger, Wayne; Lava, Val

1994-08-01T23:59:59.000Z

179

Princeton Power Systems (TRL 5 6 Component)- Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage  

Broader source: Energy.gov [DOE]

Princeton Power Systems (TRL 5 6 Component) - Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage

180

Vehicle Technologies Office Merit Review 2014: High-Voltage Solid Polymer Batteries for Electric Drive Vehicles  

Broader source: Energy.gov [DOE]

Presentation given by Seeo, Inc. at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about high-voltage solid polymer...

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Optical High Voltage Sensor with Oil- and Gas-free Insulation  

Science Journals Connector (OSTI)

We present an electro-optic high voltage sensor with novel oil- and gas-free insulation based on capacitive electric field steering. The sensor's accuracy is within ±0.2% in a...

Marchese, Sergio V; Wildermuth, Stephan; Steiger, Olivier; Pascal, Joris; Bohnert, Klaus; Eriksson, Göran; Czyzewski, Jan

182

Current mode integrators and their applications in low-voltage high frequency CMOS signal processing  

E-Print Network [OSTI]

Low voltage CMOS fully differential integrators for high frequency continuous-time filters using current-mode techniques are presented.. Current mode techniques are employed to avoid the use of the floating differential pair, in order to achieve...

Smith, Sterling Lane

2012-06-07T23:59:59.000Z

183

Low Cost SiOx-Graphite and High Voltage Spinel Cathode | Department...  

Office of Environmental Management (EM)

Cathode Low Cost SiOx-Graphite and High Voltage Spinel Cathode 2011 DOE Hydrogen and Fuel Cells Program, and Vehicle Technologies Program Annual Merit Review and Peer Evaluation...

184

High-voltage pulsed discharge in an electron source with a plasma cathode  

Science Journals Connector (OSTI)

The nature of and mechanism for producing a high-voltage discharge in an electron source with a plasma cathode are investigated. The possibility of generating pulsed electron currents with an amplitude of 103–104

S. P. Bugaev; F. Ya. Zagulov

1973-10-01T23:59:59.000Z

185

Cermet insert high voltage holdoff improvement for ceramic/metal vacuum devices  

DOE Patents [OSTI]

An improved metal-to-ceramic seal is provided wherein the ceramic body of the seal contains an integral region of cermet material in electrical contact with the metallic member, e.g., an electrode, of the seal. The seal is useful in high voltage vacuum devices, e.g., vacuum switches, and increases the high-voltage holdoff capabilities of such devices. A method of fabricating such seals is also provided.

Ierna, W.F.

1986-03-11T23:59:59.000Z

186

Voltage-dependent calcium channels and currents in native neurons and other cells have been divided into high voltage  

E-Print Network [OSTI]

Voltage-dependent calcium channels and currents in native neurons and other cells have been divided than one subtype of channel. A new subfamily of voltage-dependent calcium channel á1 subunit genes. 1999), having four domains, each with a voltage sensor and a pore-forming P loop. However

Dolphin, Annette C.

187

Optical crystal based devices for current and voltage measurement  

SciTech Connect (OSTI)

A prerequisite for safe, stable operation of an electric power system is accurate, reliable measurement of the system parameters, in particular, current and voltage. Traditionally this has been achieved on High Voltage (HV) systems by expensive, bulky iron-cored current transformers (CTs) and capacitor voltage transformers (VTs). Both these devices are increasingly coming under review in modern power systems due to their cost, safety implications for personnel and surrounding plant if failure occurs, installation time and indeed substation land requirements. This paper describes novel designs for magneto-optic and electro-optic crystal sensors providing potentially separate and combined current and voltage measurement. The results of testing programs are presented and details of the work associated with field trials given.

Cruden, A.; Richardson, Z.J.; McDonald, J.R.; Andonovic, I. [Univ. of Strathclyde (United Kingdom)] [Univ. of Strathclyde (United Kingdom)

1995-07-01T23:59:59.000Z

188

Design of AC substation grounding system.  

E-Print Network [OSTI]

??The purpose for this paper is to understand the basic foundation used to safely design a substation grounding system for AC systems. The following criteria… (more)

Meas, Ra

2014-01-01T23:59:59.000Z

189

Substation evaluation using Diagnostic Logic System (DIALOG)  

SciTech Connect (OSTI)

This project investigated the feasibility of applying a Diagnostic Logic System (DIAGLOG) to evaluate substation operation. The purpose was to see if a determination can be made as to whether the equipment in a substation operated correctly or not when an operating event occurred. The work was directed toward modifying an already proven diagnostic system to create a simplified procedure for describing the operation of substation equipment. Special operating tables or modules of logic were identified for describing relay and breaker operations. The resulting model composed of all the modules connected together is used to evaluate the actual observations available at the substation, and to compare them with what the substation should have produced. The report covers the diagnostic approach used, information on how to construct the modules and examples of diagnosis. Also covered are discussions on the special features of substations that offer a challenge to performing diagnostics. Included in the report are the results of modeling a typical substation and several notes are provided along with an initial library of typical modules which were developed in modeling one of the substations belonging to the Pacific Gas and Electric Company. This substation served as a feasibility demonstrator. 15 figs.

Andre, W.L.

1989-08-01T23:59:59.000Z

190

The Simulation Analysis of Fire Feature on Underground Substation  

Science Journals Connector (OSTI)

Underground transformer substations constructed with non-dwelling buildings have a ... out simulation analysis of fire feature on underground substation. The corresponding fire protection strategy is also...

Xin Han; Xie He; Beihua Cong

2012-01-01T23:59:59.000Z

191

Reliability Evaluation of Substations Subject to Protection Failures:.  

E-Print Network [OSTI]

??Reliability evaluation of power system substations is of significant importance when performing asset management. Most of the studies about substation reliability only focus on the… (more)

Wang, F.

2012-01-01T23:59:59.000Z

192

Substation bus arrangement performance analysis program and metrics.  

E-Print Network [OSTI]

??During preliminary substation design, only minimal information is available to the designer. Substation bus arrangements have been defined in textbooks for their advantages and disadvantages.… (more)

Oneal, Trevor Martin

2011-01-01T23:59:59.000Z

193

Distance and overcurrent protection of feeders at distribution substation.  

E-Print Network [OSTI]

??The ???Distance and Overcurrent Protection of Feeders at Distribution Substation??? report will discuss protection of distribution feeders at a substation. The paper will discuss the… (more)

Chedid, Youssef Pierre

2014-01-01T23:59:59.000Z

194

Substation Topology Analysis Based on Improved Tracking Algorithm  

Science Journals Connector (OSTI)

The substation network topology analysis is an important part ... simulation results validate that the proposed algorithm for substation network topology analysis is easy to be...

Shi Jianlei; Zhang Xuan; Zhao Qiang…

2014-01-01T23:59:59.000Z

195

Advanced communication system in substation for integrated protection  

Science Journals Connector (OSTI)

This paper proposes an advanced substation integrated protection communication system based on the ... . The integrated protection communication system within a substation comprises a number of major components s...

Jinghan He ???; Yingli Ren ???; Zhiqian Bo ???…

2008-04-01T23:59:59.000Z

196

EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild...  

Broader source: Energy.gov (indexed) [DOE]

EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild Project, Larimer County, Colorado EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild Project,...

197

Substation automation -- a ``bottoms up`` approach  

SciTech Connect (OSTI)

The proliferation of multi-purpose intelligent electronic devices in substations brought the availability of abundant and often overlapping data at the substation. This data can be used for improving the operation and maintenance of the substations and the entire power system. The objective of substation automation is to use technology to gather, consolidate and utilize this data for increasing the efficiency of power system operation and maintenance. Often automation functions are developed and offered around the capabilities of the preferred hardware and software of the integrator. Emphasis is placed on hardware, software and communication protocols rather than need, methodology and application. This can result in over-automation with complex, expensive and ineffective systems, or under-automation that fails to achieve the user`s objectives. The objective is to select appropriate hardware, software and methodology to build the most cost effective system to get the desired results. This paper describes steps to ensure the successful implementation of substation automation.

Thomas, J. [General Electric, Malvern, PA (United States)

1996-10-01T23:59:59.000Z

198

Connecting Renewables Directly to the Grid: Resilient Multi-Terminal HVDC Networks with High-Voltage High-Frequency Electronics  

SciTech Connect (OSTI)

GENI Project: GE is developing electricity transmission hardware that could connect distributed renewable energy sources, like wind farms, directly to the grid—eliminating the need to feed the energy generated through intermediate power conversion stations before they enter the grid. GE is using the advanced semiconductor material silicon carbide (SiC) to conduct electricity through its transmission hardware because SiC can operate at higher voltage levels than semiconductors made out of other materials. This high-voltage capability is important because electricity must be converted to high-voltage levels before it can be sent along the grid’s network of transmission lines. Power companies do this because less electricity is lost along the lines when the voltage is high.

None

2012-01-23T23:59:59.000Z

199

substation  

Science Journals Connector (OSTI)

This one-of-a-kind reference is unmatched in the breadth and scope of its coverage and serves as the primary reference for students and professionals in computer science and communications. The Dictionary feat...

2001-01-01T23:59:59.000Z

200

Application Analysis on EPON Technology Applied in Communication System of Smart Substation  

Science Journals Connector (OSTI)

This paper pointed out the problem that cost of communication equipments such as industrial Ethernet switch used to build the communication system of smart substation is excessively high, Analyzed the characteri...

Wei Yong; Xu Wei-guo; Zhang Yong-li…

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

A high-gain adaptive observer for detecting Li-ion battery terminal voltage collapse  

Science Journals Connector (OSTI)

We use a high-gain adaptive observer and a trend filtering algorithm to detect early stages that lead to terminal voltage collapses in Li-ion batteries. This approach allows accurate detection without having sophisticated battery models. Theoretical ... Keywords: Adaptive filters, Adaptive systems, Detection algorithms, High-gain, Trend

Shayok Mukhopadhyay, Fumin Zhang

2014-03-01T23:59:59.000Z

202

Dual design resistor for high voltage conditioning and transmission lines  

DOE Patents [OSTI]

A dual resistor for eliminating the requirement for two different value resistors. The dual resistor includes a conditioning resistor at a high resistance value and a run resistor at a low resistance value. The run resistor can travel inside the conditioning resistor. The run resistor is capable of being advanced by a drive assembly until an electrical path is completed through the run resistor thereby shorting out the conditioning resistor and allowing the lower resistance run resistor to take over as the current carrier.

Siggins, Timothy Lynn (Newport News, VA); Murray, Charles W. (Hayes, VA); Walker, Richard L. (Norfolk, VA)

2007-01-23T23:59:59.000Z

203

Optimizing performance per watt on GPUs in High Performance Computing: temperature, frequency and voltage effects  

E-Print Network [OSTI]

The magnitude of the real-time digital signal processing challenge attached to large radio astronomical antenna arrays motivates use of high performance computing (HPC) systems. The need for high power efficiency (performance per watt) at remote observatory sites parallels that in HPC broadly, where efficiency is an emerging critical metric. We investigate how the performance per watt of graphics processing units (GPUs) is affected by temperature, core clock frequency and voltage. Our results highlight how the underlying physical processes that govern transistor operation affect power efficiency. In particular, we show experimentally that GPU power consumption grows non-linearly with both temperature and supply voltage, as predicted by physical transistor models. We show lowering GPU supply voltage and increasing clock frequency while maintaining a low die temperature increases the power efficiency of an NVIDIA K20 GPU by up to 37-48% over default settings when running xGPU, a compute-bound code used in radio...

Price, D C; Barsdell, B R; Babich, R; Greenhill, L J

2014-01-01T23:59:59.000Z

204

Application of evolutionary algorithms for the planning of urban distribution networks of medium voltage  

E-Print Network [OSTI]

Abstract—Currently, an important issue in power distribution is the need to optimize medium voltage (mv) networks serving urban areas. This paper shows how an evolutionary algorithm can be used as the basis for the type of efficient algorithm such optimization demands. The search for optimal network solution will be restricted to a graph defined from the urban map, so each graph branch represents a trench. The solution space (networks) is assumed with “loop feeder circuits”: networks with two electrical paths from the high voltage/medium voltage (hv/mv) substations to the customers. In the optimization process, the investment and loss load costs are considered taking into account the constraints of conductor capacities and voltage drop. The investment costs will take into account that some cables can be lying in the same trench. The process was applied for a Spanish city of 200 000 inhabitants. Index Terms—Evolutionary algorithm, medium voltage network planning, network design, urban distribution network. I.

unknown authors

2002-01-01T23:59:59.000Z

205

Coordination of a distribution level continuously controlled compensation device with existing substation equipment for long term VAR management  

SciTech Connect (OSTI)

The implementation of a continuously controlled reactive compensation device, such as an SVC or a static condenser'' (STATCON), in a distribution-level substation provides opportunities to improve power quality and reliability due to the speed of response of such a device. Further benefits can be gained by coordinating the reactive compensation device and its related controls with other substation voltage control equipment, such as load tap changing (LTC) transformers and mechanically-switched capacitors. The results presented in this paper illustrate the impact that a [+-] 12 Mvar STATCON can have on a 150 MW, 12.5 kV load bus, in the Commonwealth Edison power system. Three control concepts for various levels of integration of the substation STATCON, LTCs, and mechanically-switched capacitors are presented. With broader application of SVCs and STATCONs at distribution substations, various other control strategies may also evolve.

Paserba, J.J.; Leonard, D.J.; Miller, N.W. (GE Industrial and Power Systems, Schenectady, NY (United States). Power Systems Engineering Dept.); Lauby, M.G. (Electric Power Research Inst., Palo Alto, CA (United States)); Naumann, S.T. (Commonwealth Edison Co., Chicago, IL (United States)); Sener, F.P. (PHE Consulting, Brecksville, OH (United States))

1994-04-01T23:59:59.000Z

206

Substation reliability -- Practical application and system approach  

SciTech Connect (OSTI)

Practical application of reliability analysis was made for the comparison of alternate line and bus arrangements of a future transmission substation with potential savings of up to $3.6 M. The paper describes how both the substation and the power system were simulated by using computer programs STAREL and COMREL. It presents the method used to obtain the most accurate estimates for the outage data of the system components. Finally, it expresses the results with simple reliability indices which can be meaningful for management. The results of the study show the need to include the reliability of the transmission system in a substation reliability evaluation.

Save, P. [Southern California Edison Co., Rosemead, CA (United States)] [Southern California Edison Co., Rosemead, CA (United States)

1995-02-01T23:59:59.000Z

207

Substation reliability -- Practical application and system approach  

SciTech Connect (OSTI)

Practical application of reliability analysis was made for the comparison of alternate line and bus arrangements of a future transmission substation with potential savings of up to 53.6 M. The paper describes how both the substation and the power system were simulated by using computer programs STAREL and COMREL. It presents the method used to obtain the most accurate estimates for the outage data of the system components. Finally, it expresses the results with simple reliability indices which can be meaningful for management. The results of the study show the need to include the reliability of the transmission system in a substation reliability evaluation.

Save, P. [Southern California Edison Co., Rosemead, CA (United States)

1994-12-31T23:59:59.000Z

208

Geomagnetically induced currents in the Uruguayan high-voltage power grid  

Science Journals Connector (OSTI)

......currents in the Uruguayan high-voltage power grid R. Caraballo 1 2 L. Sanchez Bettucci...simple topology of the Uruguayan power grid provides some advantages in the calculation...transformers at the South African power grid during the Halloween storm in 2003......

R. Caraballo; L. Sánchez Bettucci; G. Tancredi

2013-01-01T23:59:59.000Z

209

Electro-optic imagery of high-voltage GaAs photoconductive switches  

SciTech Connect (OSTI)

The authors present electro-optic images of GaAs high-voltage photoconductive switches utilizing the electro-optic effect of the semi-insulating GaAs substrate. Experimental methodology for obtaining the images is described along with a self-calibrating data reduction algorithm. Use of the technique for observing fabrication defects is shown.

Falk, R.A.; Adams, J.C.; Capps, C.D.; Ferrier, S.G.; Krinsky, J.A. (Boeing Defense and Space Group, Seattle, WA (United States))

1995-01-01T23:59:59.000Z

210

An earth-isolated optically coupled wideband high voltage probe powered by ambient light  

E-Print Network [OSTI]

(2012) Optimized working conditions for a thermoelectric generator as a topping cycle for gas turbines J (2012) Feasibility study in application of forging waste heat on absorption cooling system J. Renewable-emitting diode that converts high voltage into an amplitude-modulated optical signal, which is then conveyed

Bellan, Paul M.

211

Effect of high solenoidal magnetic fields on breakdown voltages of high vacuum 805 MHz cavities  

SciTech Connect (OSTI)

There is an on going international collaboration studying the feasibility and cost of building a muon collider or neutrino factory [1,2]. An important aspect of this study is the full understanding of ionization cooling of muons by many orders of magnitude for the collider case. An important muon ionization cooling experiment, MICE [3], has been proposed to demonstrate and validate the technology that could be used for cooling. Ionization cooling is accomplished by passing a high-emittance muon beam alternately through regions of low Z material, such as liquid hydrogen, and very high accelerating RF Cavities within a multi-Tesla solenoidal field. To determine the effect of very large solenoidal magnetic fields on the generation of dark current, x-rays and on the breakdown voltage gradients of vacuum RF cavities, a test facility has been established at Fermilab in Lab G. This facility consists of a 12 MW 805 MHz RF station and a large warm bore 5 T solenoidal superconducting magnet containing a pill box type cavity with thin removable window apertures. This system allows dark current and breakdown studies of different window configurations and materials. The results of this study will be presented. The study has shown that the peak achievable accelerating gradient is reduced by a factor greater than 2 when solenoidal field of greater than 2 T are applied to the cavity.

Moretti, A.; Bross, A.; Geer, S.; Qian, Z.; /Fermilab; Norem, J.; /Argonne; Li, D.; Zisman, M.; /LBL, Berkeley; Torun, Y.; /IIT, Chicago; Rimmer, R.; /Jefferson Lab; Errede,; /Illinois U., Urbana

2005-10-01T23:59:59.000Z

212

Partial discharge measurements on a high voltage direct current mass impregnated paper cable  

SciTech Connect (OSTI)

Partial discharge measurement has been a good tool for the quality assurance of cables under alternating voltage. With the growing interest in High Voltage Direct Current cables it seems therefore logical to extend this technique for use at direct voltage. The paper describes this technique as used on a HVDC cable with mass impregnated paper. The different phases of operation (no load, full load, cooling phase, etc.) are characterized by a different discharge behavior. Special attention is given to the dangerous cooling phase. Models have been developed which can explain the discharge patterns that were measured. This paper gives an insight in the electrical behavior of a HVDC cable with mass impregnated paper insulation.

Jeroense, M.J.P. [NKF KABEL B.V., Delft (Netherlands); Kreuger, F.H. [Delft Univ. of Technology (Netherlands)

1996-12-31T23:59:59.000Z

213

Breaking the ice: de-icing power transmission lines with high-frequency, high-voltage excitation  

E-Print Network [OSTI]

Breaking the ice: de-icing power transmission lines with high-frequency, high-voltage excitation of this work in other works must be obtained from the IEEE. #12;CING OF POWER TRANSMISSION lines during winter that applies 33-kV, 100-kHz power. TheoverallsystemisillustratedinFigure1.Itcouldbede- ployed in two different

214

Experimental adoption of RCM in EDF substations  

SciTech Connect (OSTI)

EDF, after testing Reliability Centered Maintenance (RCM) on systems used in nuclear power plants, has now successfully extended RCM to all of its nuclear power plants. In the light of this experience, EDF has committed itself to a pilot study on a line bay of a 400 kV substation in 1992. The RCM method as applied benefited from EDF`s policy of maintenance, introduced five years ago on all substations, which has enhanced prospects of reliability. The original feature in the selection of maintenance tasks was that it brought into play two criteria for failure assessment - frequency and seriousness - and two criteria for maintenance task selection - efficiency and facility. The final outcome of RCM as applied to substation maintenance is to categorize maintenance tasks into: (1) essential maintenance tasks, (2) optional tasks, depending on the type and location of the substation, as well as on factors relating to local management of maintenance policy, and (3) unnecessary tasks.

Heroin, G.; Aupied, J. [Electricite de France, Clarmart (France); Sanchis, G. [Direction EDF Production Transport, Courbevoie (France)

1996-08-01T23:59:59.000Z

215

Network Security for Substation Automation Systems  

Science Journals Connector (OSTI)

The protection of critical infrastructure against electronic and communication network based attacks becomes more and more important. This work investigates the threat of network-based attacks on substations, the...

Martin Naedele; Dacfey Dzung…

2001-01-01T23:59:59.000Z

216

Characterization of electromagnetic transients in power substations  

E-Print Network [OSTI]

CHARACTERIZATION OF ELECTROMAGNETIC TRANSIENTS IN POWER SUBSTATIONS A Thesis by WILLIAM CHESTER CiOERS, JR. Submitted to the Graduate College of Texas A&M University in partial fulfillment of the requirement for the degree of MASTER... OF SCIENCE December 1980 Major Subject: Electrical Engineering CHARACTERIZATION OF ELECTROMAGNETIC TRANSIENTS IN POWER SUBSTATIONS A Thesis by WILLIAM CHESTER GOERS, JR. Approved as to style and content by: Dr. B. Don Russell (Chairman of Committee...

Goers, William Chester

2012-06-07T23:59:59.000Z

217

Optical fiber imaging for high speed plasma motion diagnostics: Applied to low voltage circuit breakers  

SciTech Connect (OSTI)

An integrated portable measurement system is described for the study of high speed and high temperature unsteady plasma flows such as those found in the vicinity of high current switching arcs. An array of optical fibers allows the formation of low spatial resolution images, with a maximum capture rate of 1x10{sup 6} images per second (1 MHz), with 8 bit intensity resolution. Novel software techniques are reported to allow imaging of the arc; and to measure arc trajectories. Results are presented on high current (2 kA) discharge events in a model test fixture and on the application to a commercial low voltage circuit breaker.

McBride, J. W. [School of Engineering Sciences, University of Southampton, Highfield, Southampton SO17 1BJ (United Kingdom); Balestrero, A.; Tribulato, G. [ABB SACE DIVISION, ABB S.p.A., Via Baioni, Bergamo 35 IT-24123 (Italy); Ghezzi, L. [ABB SACE DIVISION, ABB S.p.A., Viale dell'Industria, Vittuone (MI)18 IT-20010 (Italy); Cross, K. J. [Taicaan Ltd., 2 Venture Road, Southampton Science Park, Southampton, Hampshire SO16 7NP (United Kingdom)

2010-05-15T23:59:59.000Z

218

High Voltage Performance of the Beam Screen of the LHC Injection Kicker Magnets  

E-Print Network [OSTI]

The LHC injection kicker magnets include beam screens to shield the ferrite yokes against wakefields resulting from the high intensity beam. The screening is provided by conductors lodged in the inner wall of a ceramic support tube. The design of the beam screen has been upgraded to overcome limitations and permit LHC operation with increasingly higher bunch intensity and short bunch lengths: the new design also significantly reduces the electric field associated with the screen conductors, decreasing the probability of electrical breakdown. The high voltage conditioning process for the upgraded kicker magnets is presented and discussed. In addition a test setup has been utilized to study flashover, on the inner wall of the ceramic tube, as a function of both applied voltage and vacuum pressure: results from the test setup are presented.

Barnes, MJ; Bregliozzi, G; Calatroni, S; Costa Pinto, P; Day, H; Ducimetičre, L; Kramer, T; Namora, V; Mertens, V; Taborelli, M

2014-01-01T23:59:59.000Z

219

Round-robin artificial contamination test on high voltage dc insulators  

SciTech Connect (OSTI)

This paper summarizes the results of a worldwide round-robin test of high voltage dc (HVDC) insulators, which was carried out in six laboratories aiming at standardization of the method for artificial contamination tests on HVDC insulators. Flashover characteristics of three kinds of specimens were evaluated by the clean fog and the salt fog procedures. Sufficient information is now available to allow the preparation of provisional international specifications for artificial contamination testing of HVDC insulators.

Naito, K.; Schneider, H.M.

1995-07-01T23:59:59.000Z

220

Ashland Area Support Substation Project : Environmental Assessment.  

SciTech Connect (OSTI)

The Bonneville Power Administration (BPA) provides wholesale electric service to the City of Ashland (the City) by transferring power over Pacific Power & Light Company`s (PP&L) 115-kilovolt (kV) transmission lines and through PP&L`s Ashland and Oak Knoll Substations. The City distributes power over a 12.5-kV system which is heavily loaded during winter peak periods and which has reached the limit of its ability to serve peak loads in a reliable manner. Peak loads under normal winter conditions have exceeded the ratings of the transformers at both the Ashland and Oak Knoll Substations. In 1989, the City modified its distribution system at the request of PP&L to allow transfer of three megawatts (MW`s) of electric power from the overloaded Ashland Substation to the Oak Knoll Substation. In cooperation with PP&L, BPA installed a temporary 6-8 megavolt-amp (MVA) 115-12.5-kV transformer for this purpose. This additional transformer, however, is only a temporary remedy. BPA needs to provide additional, reliable long-term service to the Ashland area through additional transformation in order to keep similar power failures from occurring during upcoming winters in the Ashland area. The temporary installation of another 20-MVA mobile transformer at the Ashland Substation and additional load curtailment are currently being studied to provide for sustained electrical service by the peak winter period 1992. Two overall electrical plans-of-service are described and evaluated in this report. One of them is proposed for action. Within that proposed plan-of-service are location options for the substation. Note that descriptions of actions that may be taken by the City of Ashland are based on information provided by them.

United States. Bonneville Power Administration.

1992-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Data collecting and processing for substation integration enhancement  

E-Print Network [OSTI]

The issue of substation integration is recognized as a very important one ever since the process of technological development brought a multitude of new computer-based devices and functions into substation operation. During the relatively short time...

Jakovljevic, Sasa

2004-09-30T23:59:59.000Z

222

Design, Simulation, and Analysis of Substation Automation Networks  

E-Print Network [OSTI]

on the Substation Automation Systems (SAS). Substations are nodes in the smart grid infrastructure that help the in transportation of power by connecting the transmission and distribution lines. The SAS applications are con figured to operate with minimal human...

Kembanur Natarajan, Elangovan

2012-07-16T23:59:59.000Z

223

The Study Based on IEC61850 Substation Information System Modeling  

Science Journals Connector (OSTI)

The series of international standards IEC 61850 substation communication networks and systems to provide a ... the power system. This study is the substation automation technology has entered the network developm...

Yu Xian

2013-01-01T23:59:59.000Z

224

The effect of Relay Protection on the Substation Reliability  

Science Journals Connector (OSTI)

This paper presents a model for evaluating the reliability of the substation actions after transmission grid faults. The model ... of different line protection systems by using the substation reliability model is...

Liisa Pottonen; Urho Pulkkinen…

2004-01-01T23:59:59.000Z

225

Planning substation capacity under the single-contingency scenario  

SciTech Connect (OSTI)

Florida Power and Light (FPL) adopts the single contingency emergency policy for its planning of substation capacity. This paper provides an approach to determine the maximum load which a substation can take on under such a policy. The approach consists of two LP models which determine: (1) the maximum substation load capacity, and (2) the reallocation of load when a substation`s demand cannot be met. Both models are formulated under the single-contingency scenario, an issue which had received little attention in the literature. Not only does the explicit treatment of the scenario provide an exact measure of a substation`s load limit, it also raises several important issues which previous works omit. These two models have been applied to the substation network of the Fort Myers District of the State of Florida.

Leung, L.C. [Chinese Univ. of Hong Kong, Shatin (Hong Kong). Decision Sciences and Managerial Economics] [Chinese Univ. of Hong Kong, Shatin (Hong Kong). Decision Sciences and Managerial Economics; Khator, S.K. [Univ. of South Florida, Tampa, FL (United States). Industrial and Management Systems Engineering] [Univ. of South Florida, Tampa, FL (United States). Industrial and Management Systems Engineering; Schnepp, J.C. [Crest Ultrasonics, Trenton, NJ (United States)] [Crest Ultrasonics, Trenton, NJ (United States)

1995-08-01T23:59:59.000Z

226

Security Assessment of Communication Networks for Integrated Substation Automation Systems  

Science Journals Connector (OSTI)

To assess the security of communication networks for integrated substation automation systems, a systematic approach based on ... to communication networks between the control center and substations through the a...

Huisheng Gao; Xuejiao Dai

2011-01-01T23:59:59.000Z

227

Reliability of substation protection system based on IEC61850  

Science Journals Connector (OSTI)

Although the new technology of protection and automation system of substation based on IEC61850 standard has developed rapidly...

Xiaofu Xiong ???; Jun Yu ? ?; Xiaofang Liu ???…

2008-04-01T23:59:59.000Z

228

Grounding Analysis in Heterogeneous Soil Models: Application to Underground Substations  

E-Print Network [OSTI]

Grounding Analysis in Heterogeneous Soil Models: Application to Underground Substations Ignasi category includes all step- up and step-down transmission substations, as well as a number of distribution substations indeed. Nevertheless, the current trend in electric power Engineering moves in another direction

Colominas, Ignasi

229

The Substation of the Future: A Feasibility Study  

E-Print Network [OSTI]

The Substation of the Future: A Feasibility Study Final Project Report Power Systems Engineering Research Center Empowering Minds to Engineer the Future Electric Energy System #12;Substation of the Future Engineering Research Center (PSERC) research project T-38 titled "Substation of the Future: A Feasibility

230

Short proofs of the Quantum Substate Theorem National U. Singapore  

E-Print Network [OSTI]

Short proofs of the Quantum Substate Theorem Rahul Jain National U. Singapore Ashwin Nayak U. Waterloo December 30, 2011 Abstract The Quantum Substate Theorem due to Jain, Radhakrishnan, and Sen (2002 a substate of . We present new proofs of this theorem. The resulting statement is optimal up to a constant

Nayak, Ashwin

231

Techniques for Securing Substation Automation Systems David Guidry1  

E-Print Network [OSTI]

Techniques for Securing Substation Automation Systems David Guidry1 , Mike Burmester1 , Xiuwen Liu1 propose techniques for resilient substation automation of power utility systems with security based-90-5 compliant substation automation systems that are resilient. We demonstrate the feasibility of our approach

Burmester, Mike

232

Abstract--Many functions within a substation can be performed more efficiently if all the substation data is collected  

E-Print Network [OSTI]

1 Abstract--Many functions within a substation can be performed more efficiently if all the substation data is collected from and shared among Intelligent Electronic Devices (IEDs). Gathered measurements and apparatus statuses can be processed by (local) substation computer(s). Processing includes

233

Substation flood protection: A case study  

SciTech Connect (OSTI)

On July 18, 1996, the City of Naperville, Illinois encountered a substantial storm event ranging from nine to fourteen inches of rainfall across town in less than twelve hours, with the majority falling over a four-hour period. The watershed containing the City`s Westside substation encountered the most significant rainfall totals, resulting in a flood crest in the substation area of approximately thirteen inches of water. The station is a 138 kV substation, and the flooding of this station caused a power loss to approximately 60% of the City`s customers for more than eight hours. The water level posed no threat to yard equipment, however, within the substation control building, flood water shorted out control circuits and damaged transmission line relay systems. Crews worked round-the-clock for most of a week to return all transmission lines and transformers to normal service. The 15 kV switchgear ultimately had to be replaced due to recurring control circuit problems. Once the station was restored and the cleanup efforts underway, the City embarked on an evaluation to determine what condition or conditions allowed the flooding to occur, and what could be done in the future to avoid this problem to ensure that the customers of Naperville would not experience another service outage of this magnitude due to flooding.

Gacek, D.B. [City of Naperville, IL (United States); McGovern, L.L. [Burns and McDonnell, Westmont, IL (United States)

1999-11-01T23:59:59.000Z

234

Utility programs for substation diagnostics development  

SciTech Connect (OSTI)

This article is a brief overview of the opening remarks of the utility panel. These remarks developed a number of interesting substation diagnostic activities and concepts in which the electric utilities are engaged and outlined the considerations which must accompany development of diagnostic sensors and systems. These area include transformer diagnostics, circuit breaker diagnostics, and testing/cost of diagnostic systems.

NONE

1996-03-01T23:59:59.000Z

235

Influence of energy contributions to a high-voltage atmospheric-pressure discharge on the efficiency of conversion of ethanol  

Science Journals Connector (OSTI)

The results of experimental investigations of the conversion of ethanol in a high-voltage atmospheric-pressure discharge have been presented. The influence of the energy parameters of the discharge on the yield a...

S. A. Zhdanok; A. V. Krauklis; P. P. Samtsov…

2006-11-01T23:59:59.000Z

236

A high voltage test stand for electron gun qualification for LINACs  

SciTech Connect (OSTI)

An electron gun lest stand has been developed at RRCAT. The test stand consists of a high voltage pulsed power supply, electron gun filament supply, grid supply, UHV system and electron gun current measurement system. Several electron guns developed indigenously were evaluated on this test stand. The shielding is provided for the electron gun set up. Electron gun tests can be tested upto 55 kV with pulse width of 15 microsecs and pulse repetition rates up to 200 Hz. The technical details of the subsystems are furnished and results of performance of the test stand have been reported in this paper. (author)

Wanmode, Yashwant D.; Mulchandani, J.; Acharya, M.; Bhisikar, A.; Singh, H.G.; Shrivastava, Purushottam, E-mail: yash@rrcat.gov.in [Pulsed High Power Microwave Section, Raja Ramanna Centre for Advanced Technology, Indore (India)

2011-07-01T23:59:59.000Z

237

A Fusing Switch for Fault Suppression in the SNS High Voltage Converter Modulators  

SciTech Connect (OSTI)

The High Voltage Converter Modulators (HVCMs) at the Spallation Neutron Source (SNS) have operated in excess of a combined 250,000 hours. Performance and reliability improvements to the HVCM are ongoing to increase modulator availability as accelerator system demands increase. There is a relatively large amount of energy storage in the HVCMs, {approx}180 kJ. This energy has the potential to dump into unsuppressed faults, cause damage, and increase the time to repair. The 'fusing switch' concept involves isolation of this stored energy from the location of the most common faults. This paper introduces this concept and its application to the HVCMs.

Kemp, Mark A.; Burkhart, Craig; Nguyen, Minh N.; /SLAC; Anderson, David E.; /Oak Ridge

2009-08-03T23:59:59.000Z

238

High voltage power supplies for the neutral beam injectors of the stellarator TJ-II  

Science Journals Connector (OSTI)

Neutral beam injection will be available for the second experimental phase of TJ-II. Two injectors, set in co-counter configuration, will inject into the plasma two 40 keV H0 beams, each of up to 1 MW. The two high voltage power supplies to feed the acceleration grids of the injectors, described in this paper, are of the transformer–rectifier type, taking their primary energy from a pulsed flywheel generator, and are coupled to the acceleration grids through a switching device. This environment effectively sets the main operation limits and protection requirements of the power supplies.

J Alonso; M Liniers; L Mart??nez Laso; E Jauregi; C Luc??a; F Valcárcel

2001-01-01T23:59:59.000Z

239

Design Techniques for High Speed Low Voltage and Low Power Non-Calibrated Pipeline Analog to Digital Converters  

E-Print Network [OSTI]

DESIGN TECHNIQUES FOR HIGH SPEED LOW VOLTAGE AND LOW POWER NON-CALIBRATED PIPELINE ANALOG TO DIGITAL CONVERTERS A Dissertation by RIDA SHAWKY ASSAAD Submitted to the Office of Graduate Studies of Texas A&M University... in partial fulfillment of the requirements for the degree of DOCTOR OF PHILOSOPHY December 2009 Major Subject: Electrical Engineering DESIGN TECHNIQUES FOR HIGH SPEED LOW VOLTAGE AND LOW POWER NON-CALIBRATED PIPELINE ANALOG TO DIGITAL...

Assaad, Rida Shawky

2011-02-22T23:59:59.000Z

240

High-voltage nanosecond pulses in a low-pressure radio-frequency discharge  

Science Journals Connector (OSTI)

An influence of a high-voltage (3–17 kV) 20 ns pulse on a weakly-ionized low-pressure (0.1–10 Pa) capacitively coupled radiofrequency (RF) argon plasma is studied experimentally. The plasma evolution after pulse exhibits two characteristic regimes: a bright flash, occurring within 100 ns after the pulse (when the discharge emission increases by 2–3 orders of magnitude over the steady-state level), and a dark phase, lasting a few hundreds ?s (when the intensity of the discharge emission drops significantly below the steady-state level). The electron density increases during the flash and remains very large at the dark phase. 1D3V particle-in-cell simulations qualitatively reproduce both regimes and allow for detailed analysis of the underlying mechanisms. It is found that the high-voltage nanosecond pulse is capable of removing a significant fraction of plasma electrons out of the discharge gap, and that the flash is the result of the excitation of gas atoms, triggered by residual electrons accelerated in the electric field of immobile bulk ions. The secondary emission from the electrodes due to vacuum UV radiation plays an important role at this stage. High-density plasma generated during the flash provides efficient screening of the RF field (which sustains the steady-state plasma). This leads to the electron cooling and, hence, onset of the dark phase.

M. Y. Pustylnik; L. Hou; A. V. Ivlev; L. M. Vasilyak; L. Couëdel; H. M. Thomas; G. E. Morfill; V. E. Fortov

2013-06-10T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Measurement of low radioactivity background in a high voltage cable by high resolution inductively coupled plasma mass spectrometry  

SciTech Connect (OSTI)

The measurement of naturally occurring low level radioactivity background in a high voltage (HV) cable by high resolution inductively coupled plasma mass spectrometry (HR ICP MS) is presented in this work. The measurements were performed at the Chemistry Service of the Gran Sasso National Laboratory. The contributions to the radioactive background coming from the different components of the heterogeneous material were separated. Based on the mass fraction of the cable, the whole contamination was calculated. The HR ICP MS results were cross-checked by gamma ray spectroscopy analysis that was performed at the low background facility STELLA (Sub Terranean Low Level Assay) of the LNGS underground lab using HPGe detectors.

Vacri, M. L. di; Nisi, S.; Balata, M. [Gran Sasso National Laboratory, Chemistry Service, SS 17bis km 18.910, 67100 Assergi (Aq) (Italy)] [Gran Sasso National Laboratory, Chemistry Service, SS 17bis km 18.910, 67100 Assergi (Aq) (Italy)

2013-08-08T23:59:59.000Z

242

Software-Based Challenges of Developing the Future Distribution Grid  

E-Print Network [OSTI]

be  used,  either  in  substations  or  farther  down  the  to  be  sectionalized.    Substations  and  geographical  system  equivalence  at  the  substation  high-­?voltage  

Stewart, Emma

2014-01-01T23:59:59.000Z

243

Conformational Diversity and Sub-states in Enzyme Catalysis | ornl.gov  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Conformational Diversity and Sub-states in Enzyme Catalysis Conformational Diversity and Sub-states in Enzyme Catalysis November 01, 2013 Enzymes are great biocatalysts, and have attracted significant interest for industrial applications (including cellulosic ethanol) due to their remarkable catalytic efficiencies. The understanding of factors that enable enzymes to achieve the high catalytic efficiency will have large impact through design of new and powerful biocatalysts. Unfortunately, the understanding of these factors have largely remain a mystery so far. Using joint computational-experimental methodology we have developed a unique technique named quasi-anharmonic analysis (QAA) for identification of conformational diversity and conformational sub-states associated with enzyme function. As a result of this approach we have been able to develop

244

Research on fuzzy logic based dynamic boundary voltage and reactive power integrated control method  

Science Journals Connector (OSTI)

Aiming at the existing problems of conventional substation voltage and reactive power integrated control method, a new fuzzy logic based dynamic reactive power boundary voltage and reactive power integrated control method is proposed. Fuzzy logic control ... Keywords: dynamic boundary, fuzzy logic, reactive power, voltage

Zigang Xu; Fei Wang

2009-06-01T23:59:59.000Z

245

Monolithically interconnected GaAs solar cells: A new interconnection technology for high voltage solar cell output  

SciTech Connect (OSTI)

Photovoltaic linear concentrator arrays can benefit from high performance solar cell technologies being developed at AstroPower. Specifically, these are the integration of thin GaAs solar cell and epitaxial lateral overgrowth technologies with the application of monolithically interconnected solar cell (MISC) techniques. This MISC array has several advantages which make it ideal for space concentrator systems. These are high system voltage, reliable low cost monolithically formed interconnections, design flexibility, costs that are independent of array voltage, and low power loss from shorts, opens, and impact damage. This concentrator solar cell will incorporate the benefits of light trapping by growing the device active layers over a low-cost, simple, PECVD deposited silicon/silicon dioxide Bragg reflector. The high voltage-low current output results in minimal 12R losses while properly designing the device allows for minimal shading and resistance losses. It is possible to obtain open circuit voltages as high as 67 volts/cm of solar cell length with existing technology. The projected power density for the high performance device is 5 kW/m for an AMO efficiency of 26% at 1 5X. Concentrator solar cell arrays are necessary to meet the power requirements of specific mission platforms and can supply high voltage power for electric propulsion systems. It is anticipated that the high efficiency, GaAs monolithically interconnected linear concentrator solar cell array will enjoy widespread application for space based solar power needs. Additional applications include remote man-portable or ultra-light unmanned air vehicle (UAV) power supplies where high power per area, high radiation hardness and a high bus voltage or low bus current are important. The monolithic approach has a number of inherent advantages, including reduced cost per interconnect and increased reliability of array connections. There is also a high potential for a large number of consumer products.

Dinetta, L.C.; Hannon, M.H.

1995-10-01T23:59:59.000Z

246

Marion Industrial Substation Project : Environmental Assessment.  

SciTech Connect (OSTI)

Consumers Power, Inc. (CPI), proposes to construct a new distribution substation under the existing Bonneville Power Administration (BPA) Albay-Lebanon transmission line near the city of Albany in Linn County, Oregon. BPA is proposing to grant a new Point of Delivery to CPI at this substation. The purpose of the project is to serve the developing industrial needs in the Marion Industrial Park and on the 550 acres of nearby land within CPI's service area that are zoned for residential use. CPI prepared, and the Rural Electrification Administration (REA) has approved a Borrower's Environmental Report (BER) which addresses this action along with several other proposed projects in the CPI service area. Portions of this BER are summarized in this brief EA. BPA is preparing its own EA since Department of Energy National Environmental Policy Act (NEPA) guidelines require additional environmental concerns to be addressed than are required by REA's NEPA guidelines.

United States. Bonneville Power Administration.

1992-04-01T23:59:59.000Z

247

Marion Industrial Substation Project : Environmental Assessment.  

SciTech Connect (OSTI)

Consumers Power, Inc. (CPI), proposes to construct a new distribution substation under the existing Bonneville Power Administration (BPA) Albay-Lebanon transmission line near the city of Albany in Linn County, Oregon. BPA is proposing to grant a new Point of Delivery to CPI at this substation. The purpose of the project is to serve the developing industrial needs in the Marion Industrial Park and on the 550 acres of nearby land within CPI`s service area that are zoned for residential use. CPI prepared, and the Rural Electrification Administration (REA) has approved a Borrower`s Environmental Report (BER) which addresses this action along with several other proposed projects in the CPI service area. Portions of this BER are summarized in this brief EA. BPA is preparing its own EA since Department of Energy National Environmental Policy Act (NEPA) guidelines require additional environmental concerns to be addressed than are required by REA`s NEPA guidelines.

United States. Bonneville Power Administration.

1992-04-01T23:59:59.000Z

248

Short proofs of the Quantum Substate Theorem  

E-Print Network [OSTI]

The Quantum Substate Theorem due to Jain, Radhakrishnan, and Sen (2002) gives us a powerful operational interpretation of relative entropy, in fact, of the observational divergence of two quantum states, a quantity that is related to their relative entropy. Informally, the theorem states that if the observational divergence between two quantum states rho, sigma is small, then there is a quantum state rho' close to rho in trace distance, such that rho' when scaled down by a small factor becomes a substate of sigma. We present new proofs of this theorem. The resulting statement is optimal up to a constant factor in its dependence on observational divergence. In addition, the proofs are both conceptually simpler and significantly shorter than the earlier proof.

Rahul Jain; Ashwin Nayak

2011-03-31T23:59:59.000Z

249

INSITE: An emerging standard for substation monitoring  

SciTech Connect (OSTI)

The functions of the INSITE Substation Apparatus Monitoring System can be broken into two, somewhat arbitrary categories. (1) Data acquisition, storage and communications, (2) Data analysis and apparatus condition assessment. We have defined the first set of functions as comprising the {open_quotes}platform{close_quotes}, the second as an {open_quotes}application{close_quotes}. We have made the distinction to encourage users to contemplate other possible {open_quotes}applications{close_quotes} which may be implemented using the platform. The intent of this paper is to describe in detail the platform functions. The requirements for the platform derive from several overall goals of a substation apparatus monitoring system: (1) Comprehensive: The ability to monitor all important types of substation apparatus, combined with all the tools - the sensors, the Data Acquisition Unit, and the analysis and communications software - for an on-line, real-time condition assessment of your equipment, with critical information at everyone`s fingertips. (2) Dependable: Built-in self-diagnosis that assures optimum system performance. (3) Reliable: From an extremely hot to extremely cold environment, capable of functioning reliably in electrically noisy substations. (4) Expandable: Easily upgradable to accommodate additional sensors available today and any new types developed tomorrow - as well as new software, for monitoring other equipment down the road. (5) Open: The ability to accept non-Doble supplied sensors - with future capability for integrating RS-232-compatible intelligent sensors. (6) Complementary: Compatibility with existing DTA technology, for example, making comparison of both out-of-service and in-service data possible. (7) Easy-to-Use: A Windows application with user-friendly pull-down menus, simple icons and buttons, and dialog sessions that can be mastered easily. On-line Help is also available. (8) Lowest possible cost.

Woodward, R.C. [Doble Engineering Company, Watertown, MA (United States)

1996-03-01T23:59:59.000Z

250

Distribution capacitor automation that controls voltage and saves energy  

SciTech Connect (OSTI)

The Electric Distribution Business Line of Southern California Edison Company (SCE) has begun a program to improve the distribution system operations and electrical efficiency. The program, called the Distribution System Efficiency Enhancement Program (DSEEP), consists of five principal projects: Automated Switching, Circuit Lock-Out Alarming, Substation Monitoring and Control, Outage Management, and Distribution Capacitor Automation Project (DCAP). DCAP is the largest and most sophisticated of the projects being implemented. The project takes advantage of fine-tuning customer voltages for conservation voltage regulation (CVR) benefits as well as minimizes line losses by reducing unnecessary reactive power flow. DCAP can also help to increase transmission line and substation capacity by improving system power factor. The DCAP system takes advantage of the distributed processing capability of meters, capacitor controllers, radios, and substation processors. DCAP uses two-way packet radios and new electronic meters that read real-time customer voltages as well as energy consumption. The radios transmit customer meter voltage information and capacitor status to substation processors, where a control algorithm runs to determine which capacitors should be turned on or off. The objective of DCAP is to reduce over-all net energy transfer from the substation to the customer and meet system VAR requirements. SCE has tested the system on 66 circuit capacitors (including 3 substation capacitors) on 18 circuits served from two substations. The positive results of the DCAP demonstrations has led to an aggressive roll-out plan for system-wide implementation of automating over 7600 switched capacitors by year-end 1995.

Williams, B.R.

1994-12-31T23:59:59.000Z

251

ANUEADflM-31 Electric Power High-Voltage Transmission Lines:  

Office of Scientific and Technical Information (OSTI)

ANUEADflM-31 ANUEADflM-31 Electric Power High-Voltage Transmission Lines: Design Options, Cost, and Electric and Magnetic Field Levels by J.B. Stoffel,' E.D. Pentecost, R.D. Roman, and P.A. Traczyk Environmental Assessment Division, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 November 1994 Work sponsored by United States Department of Energy, Assistant Secretary for Fossil Energy, Office of Fuels Program Stoffel is affiliated with Argonne's Electronics and Computing Technologies Division. D4SlRlBUTlON OF THIS DOCUMENT IS UNLiMltEb - . - . - . - . ... - , . ^ ~ .. , . . . , . . _ I T h i s report i s printed on recycled paper. @ . . .. . ' . . . A :_ - .. ., . . DISCLAIMER This report was .prepared as an account of work sponsored by an agency of the United States Government. Neither

252

ESS 2012 Peer Review - Low Cost, Manufacturable High Voltage Power Module for ESS - Brandon Passmore, APEI  

Broader source: Energy.gov (indexed) [DOE]

W. Research Center Blvd. * Fayetteville, AR 72701 * (479) 443-5759 W. Research Center Blvd. * Fayetteville, AR 72701 * (479) 443-5759 Design and Development of a Low Cost, Manufacturable High Voltage Power Module for Energy Storage Systems Phase I SBIR September 27, 2012 Brandon Passmore, PhD Sr. Electronics Packaging Research Engineer Email: bpassmo@apei.net Acknowledgements * I would like to thank Dr. Imre Gyuk of the DOE Energy Storage Systems Program and Dr. Stan Atcitty for technical support * I would also like to thank 2 Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

253

Artificial SEI Enables High-Voltage Lithium-ion Batteries | ornl.gov  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Functional Materials for Energy Functional Materials for Energy Artificial SEI Enables High-Voltage Lithium-ion Batteries September 03, 2013 Efficacy of Lipon coating as an artificial SEI for suppression of electrolyte decomposition on a 5V spinel cathode: coulombic efficiency was measured versus cycle numbers at samples with different coating thickness. An artificial solid electrolyte interphase (SEI) of lithium phosphorus oxynitride (Lipon) enables the use of 5V cathode materials with conventional carbonate electrolytes in lithium-ion batteries. Five volt cathode materials, such as LiNi0.5Mn1.5O4, are desirable to provide higher energy, however conventional carbonate electrolytes decompose above 4.5V compromising the battery performance. This work shows that Lipon coating suppresses the electrolyte decomposition, as measured by the

254

High open circuit voltages of solar cells based on quantum dot and dye hybrid-sensitization  

SciTech Connect (OSTI)

A type of solar cell based on quantum dot (QD) and dye hybrid-sensitized mesoporous TiO{sub 2} film electrode was designed and reported. The electrode was consisted of a TiO{sub 2} nanoparticle (NP) thin film layer sensitized with CdS quantum dot (QD) and an amorphous TiO{sub 2} coated TiO{sub 2} NP thin film layer that sensitized with C106 dye. The amorphous TiO{sub 2} layer was obtained by TiCl{sub 4} post-treatment to improve the properties of solar cells. Research showed that the solar cells fabricated with as-prepared hybrid-sensitized electrode exhibited excellent photovoltaic performances and a fairly high open circuit voltage of 796?mV was achieved.

Zhao, Yujie; Zhao, Wanyu; Chen, Jingkuo; Li, Huayang; Fu, Wuyou, E-mail: hari@hpu.edu.cn, E-mail: fuwy56@163.com; Sun, Guang; Cao, Jianliang; Zhang, Zhanying [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China)] [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China); Bala, Hari, E-mail: hari@hpu.edu.cn, E-mail: fuwy56@163.com [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China) [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China); College of Chemistry and Chemical Engineering, Inner Mongolia University for the Nationalities, Tongliao 028043 (China)

2014-01-06T23:59:59.000Z

255

Constructing ‘population’ criteria for the comparison of different options for a high voltage line route  

Science Journals Connector (OSTI)

This paper presents a method for comparing the sensitiveness of people to different possible options for the route of High Voltage transmission lines. It has been tested on practical cases. First, we create special dimensions and scales in order to evaluate the different zones of a studied area. Then, the different options for the route of HV lines (which are a succession of different zones) have to be compared. The construction of criteria permitting the comparison of different options raises a theoretical issue: how to punctualise the geographic distribution or the grades of the different zones of an option, in order to reflect preferences? Different methods of punctualisation are proposed which could apply to other cases. But the purpose of the paper is merely to show that these methods of punctualisation are not neutral, they cannot reflect all the characteristics of a distribution of grades.

Nathalie Grassin

1986-01-01T23:59:59.000Z

256

Categorical Exclusion (CX) Determination Proposed Action: Havre Substation, Stage 03.  

Broader source: Energy.gov (indexed) [DOE]

Havre Substation, Stage 03. Havre Substation, Stage 03. Description of Proposed Action: The Western Area Power Administration (Western) is proposing to expand the Havre Substation approximately 150 ft to the north to accommodate a new delivery service from the newly built Herron Substation by Hill County. The expansion also converts the existing 115-kV single bus into a ring bus which will improve reliability. Western is also expanding the yard to the east to accommodate the replacement of the existing control building and control boards. Number and Title of Categorical Exclusions Being Applied: 10 CFR 1021.410 Subpart D, Appendix B, B4.11: Construction of electric power substations .. . or modification of existing substations and support facilities . Regulatory Requirements for CX Determination: The DOE Guidelines for Compliance with

257

Low-Variation 1 MHz Clock Generator,High Sensitivity Linear Voltage-to-Frequency Converter,and High-PSR Bias Circuit for NTSC SYNC Separation.  

E-Print Network [OSTI]

??This thesis includes three topics. The first topic is a low-variation 1 MHz clock generator. The second one is a high sensitivity linear voltage-to-frequency converter.… (more)

Lee, Tzung-Je

2004-01-01T23:59:59.000Z

258

Report of Experiments at Substation No. 11, Nacogdoches, Texas.  

E-Print Network [OSTI]

XAS AGRICULTURAL EXPERIMENT STATION AGRICULTURAL AND MECHANICAL COLLEGE OF TEXAS W. B. BiZZELL. President BULLETIN NO. 254 - NOVEMBER, 19 19 - -- REPORT OF EXPERIMENTS AT SUBSTATION NO. 1 1, NACOGDOCHES, TEXAS - $ B. YOUNGBLOOD, DIRECTOR... of veterinkj ~edkine. A: & M. College of Texas. **In cooperation with the United States Department of Agriculture. REPORT OF EXPERIMENTS AT SUBSTATION NO. 11, NACOGDOCHES, TEXAS. The substation at Nacogdoches is located two and three-fourths iliiles north...

McNess, George Thomas

1919-01-01T23:59:59.000Z

259

Report of Experiments at Substation No. 4, Beaumont, Texas.  

E-Print Network [OSTI]

**W. T. CARTER, JR., B. S.: Chtej T. M. BUSHNELL. B. S.. Sod Suroegur W. B. FRANCIS. B. S.. Soil Sur~euor bondman I?. G. BREWER, B. S., Assisfanf Animal Hus- bandman -- , Soil Sur&yor SUBSTATIONS No. 1. Beeville, Bee County I. E. COWART. M. S... : 19 a.7mm ary ................................................. 20 [Blank Page in Original Bulletin] REPORT OF EXPERIMENTS, SUBSTATION NO. 4, ' BEAUMONT, TEXAS. Substation No. 4, located six miles west of Beaumont, in one of the largest rice...

Laude, H. H. (Hilmer Henry)

1919-01-01T23:59:59.000Z

260

Knowledge engineering tool for training power-substation operators  

SciTech Connect (OSTI)

Artificial intelligence techniques have been applied to create systems that can give answers for different situations and assistance during the substation switching operation. These techniques have also been used for training purposes. This paper presents a computational package for training power substation operators in the control and corrective actions using expert system techniques. Illustrative examples are presented using a 138-kV CEMIG substation.

Lambert-Torres, G. [Escola Federal de Engenharia de Itajuba (Brazil)] [Escola Federal de Engenharia de Itajuba (Brazil); [Univ. of Waterloo, Ontario (Canada); Costa, C.I.A.; Alves da Silva, A.P. [Escola Federal de Engeharia de Itajuba (Brazil)] [Escola Federal de Engeharia de Itajuba (Brazil); Ribeiro, G.M. [Companhia Energetica de Minas Gerais (Brazil)] [Companhia Energetica de Minas Gerais (Brazil); Quintana, V.H. [Univ. of Waterloo, Ontario (Canada)] [Univ. of Waterloo, Ontario (Canada)

1997-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Application of programmable logic controllers to substation control and protection  

SciTech Connect (OSTI)

This paper describes the application of programmable logic controllers (PLCs) to control and protection of bulk power and regional supply substations. PLC requirements are discussed and the concept of zones of control is explained as applied to standard PP L substation arrangements. The use of a peer-to-peer communication network between logic controllers and other substation equipment is also discussed. Details of an installation completed in spring, 1992, are presented, including experience acquired from power system faults.

Gilbert, J.G.; Diehl, G.R. (Pennsylvania Power Light Co., Allentown, PA (United States))

1994-01-01T23:59:59.000Z

262

Holbrook Substation Superconductor Cable System, Long Island, New York Final Report  

SciTech Connect (OSTI)

The LIPA Superconductor project broke ground on July 4, 2006, was first energized on April 22, 2008 (Earth Day) and was commissioned on June 25, 2008. Since commissioning, up until early March, 2009, there were numerous refrigeration events that impacted steady state operations. This led to the review of the alarms that were being generated and a rewrite of the program logic in order to decrease the hypersensitivity surrounding these alarms. The high temperature superconductor (HTS) cable was energized on March 5, 2009 and ran uninterrupted until a human error during a refrigeration system switchover knocked the cable out of the grid in early February 2010. The HTS cable was in the grid uninterrupted from March 5, 2009 to February 4, 2010. Although there have been refrigeration events (propagated mainly by voltage sags/surges) during this period, the system was able to automatically switch over from the primary to the backup refrigeration system without issue as required during this period. On February 4, 2010, when switching from the backup over to the primary refrigeration system, two rather than one liquid nitrogen pumps were started inadvertently by a human error (communication) causing an overpressure in the cable cooling line. This in turn activated the pressure relief valve located in the grounding substation. The cable was automatically taken out of the grid without any damage to the components or system as a result of signals sent from the AMSC control cabinet to the LIPA substation. The cable was switched back into the grid again on March 16, 2010 without incident and has been operational since that time. Since switching from the backup to the primary is not an automatic process, a recent improvement was added to the refrigeration operating system to allow remote commands to return the system from backup to primary cooling. This improvement makes the switching procedure quicker since travel to the site to perform this operation is no longer necessary and safer since it is now a programmed procedure versus the former written procedure that was still subject to human variation in the process.

Maguire, James; McNamara, Joseph

2010-06-25T23:59:59.000Z

263

New live line tester for porcelain suspension insulators on high-voltage power lines  

SciTech Connect (OSTI)

Suspension insulator assemblies known as insulator strings are used in overhead power transmission lines to mechanically support high-voltage conductors while providing adequate insulation to withstand switching and lightning overvoltages. Since the useful life in service of the individual insulator elements making up these strings is hard to predict, they must be verified periodically to insure that adequate line reliability is maintained at all times. Over the years many testing methods have been used for this purpose, each one with its own advantages and disadvantages. Until now at Hydro-Quebec, porcelain insulators had been tested by the buzz method which simply consists of applying a short-circuit to each insulator in a string and listening for a buzz-like sound indicating a good insulator. However, safety considerations that preclude short-circuiting insulators and other disadvantages of that method have led Hydro-Quebec to undertake and complete the development of a new insulator tester. The working principle of this new device is based on the automatic measurement and recording of the electric field along the insulator string which decreases considerably in front of an internally-shorted insulator. The tester is slid along the string while the insulators are counted automatically. The information from tests on up to 200 strings can be stored in the device to be later transferred in a host computer for interpretation and/or permanent storage. The new tester also gives information on voltage distribution along the insulator strings which can be useful for the design of future power transmission lines.

Vaillancourt, G.H.; St-Jean, M. (Hydro-Quebec, Varennes, Quebec (Canada)); Bellerive, J.P. (Hydro-Quebec, Montreal, Quebec (Canada)); Jean, C. (Positron Inc., Montreal, Quebec (Canada))

1994-01-01T23:59:59.000Z

264

Environmental Assessment of Proposed Filbert Substation and Tap Project.  

SciTech Connect (OSTI)

The proposal is a cooperative (jointly funded and owned) action between Bonneville Power Administration (BPS) and FGLandP involving construction of the 115/12.5-kV Filbert Substation. BPA would also build a 0.8-mile overhead 115-kV tapline from BPA's Forest Grove-McMinnville 115-kV line to the proposed substation. The Forest Grove-McMinnville transmission line has available capacity to support the proposed substation. The FGLandP would build four underground distribution circuits to connect the substation to its existing distribution system. It is normally BPA's practice to consider several substation location alternatives as a part of its facility siting process. The proposed substation site was recommended after a preliminary field evaluation by BPA determined that building on the proposed site was preferable because available sites south of the Tualatin Valley Highway and Southern Pacific Railroad were either on presently cultivated farmland, were in a floodplain, or were inaccessible without extensive access road construction. The proposed substation site is owned by FGLandP, is designated for use as a utility substation in the Forest Grove Comprehensive Plan, and was purchased by FGLandP in anticipation of a need for its use as a substation site because of its central location in relation to existing and forecasted loads. The site is accessible from Filbert Street (city road), and is gently sloping. This report describes potential environmental impacts of the proposed actions.

United States. Bonneville Power Administration.

1984-03-01T23:59:59.000Z

265

Design and dimensioning of pressure vessel for a marine substation.  

E-Print Network [OSTI]

?? This thesis presents the mechanical design and dimensioning of a pressure vessel, which is to be used as housing for a marine substation in… (more)

Eriksson, Lars

2010-01-01T23:59:59.000Z

266

On divergence, relative entropy and the substate property  

E-Print Network [OSTI]

In this article we study relationship between three measures of distinguishability of quantum states called as divergence, relative entropy and the substate property.

Jain, R; Sen, P; Jain, Rahul; Radhakrishnan, Jaikumar; Sen, Pranab

2005-01-01T23:59:59.000Z

267

Wireless technology(ZigBee) for communication in substation.  

E-Print Network [OSTI]

??Automation plays a important role in the electric substation. The lack of controlling and monitoring the devices may cause accidents. So automation of devices is… (more)

Kandela, Amit

2013-01-01T23:59:59.000Z

268

On divergence, relative entropy and the substate property  

E-Print Network [OSTI]

In this article we study relationship between three measures of distinguishability of quantum states called as divergence, relative entropy and the substate property.

Rahul Jain; Jaikumar Radhakrishnan; Pranab Sen

2005-06-24T23:59:59.000Z

269

Studies of Monitoring and Diagnosis Systems for Substation Apparatus.  

E-Print Network [OSTI]

??Substation apparatus failure plays a major role in reliability of power delivery systems. Traditionally, most utilities perform regular maintenance in order to prevent equipment breakdown.… (more)

Liang, Yishan

2006-01-01T23:59:59.000Z

270

Substation automation systems and IEC 61850: interoperability testing.  

E-Print Network [OSTI]

??Dissertaçăo de mest., Engenharia Electrónica e Telecomunicaçőes, Faculdade de Cięncias e Tecnologia, Univ. do Algarve, 2011 The Substation Automation System (SAS) is the backbone of… (more)

Evaristo, Henrique A. Guerreiro Dias

2011-01-01T23:59:59.000Z

271

Mechanisms of deflagration-to-detonation transition under initiation by high-voltage nanosecond discharges  

SciTech Connect (OSTI)

An experimental study of detonation initiation in a stoichiometric propane-oxygen mixture by a high-voltage nanosecond gas discharge was performed in a detonation tube with a single-cell discharge chamber. The discharge study performed in this geometry showed that three modes of discharge development were realized under the experimental conditions: a spark mode with high-temperature channel formation, a streamer mode with nonuniform gas excitation, and a transient mode. Under spark and transient initiation, simultaneous ignition inside the discharge channel occurred, forming a shock wave and leading to a conventional deflagration-to-detonation transition (DDT) via an adiabatic explosion. The DDT length and time at 1 bar of initial pressure in the square smooth tube with a 20-mm transverse size amounted to 50 mm and 50{mu}s, respectively. The streamer mode of discharge development at an initial pressure of 1 bar resulted in nonuniform mixture excitation and a successful DDT via a gradient mechanism, which was confirmed by high-speed time resolved ICCD imaging. The gradient mechanism implied a longer DDT time of 150{mu}s, a DDT run-up distance of 50 mm, and an initiation energy of 1 J, which is two orders of magnitude less than the direct initiation energy for a planar detonation under these conditions. (author)

Rakitin, Aleksandr E.; Starikovskii, Andrei Yu. [Physics of Nonequilibrium Systems Lab, Moscow Institute of Physics and Technology, 9 Institutski Lane, Dolgoprudny 141700 (Russian Federation)

2008-10-15T23:59:59.000Z

272

Bonneville Power Administration is investigating wide-area stability and voltage control. The control provides a flexible  

E-Print Network [OSTI]

. There will also be synergy between wide-area control and substation automation (e.g., intelligent electronic Adminis- tration (BPA). For the past decade, wintertime voltage stability has been a major concern [1

Venkatasubramanian, Mani V.

273

The Design of Partial Electric and Control System for 500kV Substation  

Science Journals Connector (OSTI)

The good design of the electric section in substation and its stable move may effect the electrical system of substation directly, this paper aim at the design of an electric primary section in substation and its...

Haimei Xiao; Lichun Shi

2012-01-01T23:59:59.000Z

274

A New Method for Substation Planning Problem Based on Weighted K-Means  

Science Journals Connector (OSTI)

Substation planning is considered the most important step ... and distribution system. In this paper, the substation planning problem is looked as a clustering ... loads into several clusters. The capacity of substation

Wen Peng; Wenxia Liu

2009-01-01T23:59:59.000Z

275

Novel Approach for Detecting Network Anomalies for Substation Automation based on IEC 61850  

Science Journals Connector (OSTI)

An SA (Substation Automation) system based on IEC 61850 is an intelligent substation; it has been receiving considerable attention as ... critical national infrastructures including the power grid. Substation Aut...

Hyunguk Yoo; Taeshik Shon

2014-03-01T23:59:59.000Z

276

Environmental Assessment : Happy Valley [Substation Project].  

SciTech Connect (OSTI)

The proposed Happy Valley project consists of construction of a new BPA customer service 69-kV substation south of Sequim in Clallam County, Washington. A tie line, to be constructed by the customer as part of this project, will link the new BPA facility to the existing customer's transmission system in the area. This project responds to rapid load growth in the Olympic Peninsula, and will strengthen the existing BPA system and interconnected utility systems. It will reduce transmission losses presently incurred, especially on the BPA system supplying power to the Olympic Peninsula. This report describes the potential environmental impact of the proposed actions. 2 figs., 1 tab.

United States. Bonneville Power Administration.

1982-05-01T23:59:59.000Z

277

The Remote Video Monitoring System Design and Development for Underground Substation Construction Process  

Science Journals Connector (OSTI)

From the current situation of underground substation construction in China, we design and development ... image enhancement technology, the construction of underground substation can be clearly and accurately tra...

Siguo Zheng; Yugan You; Fanguang Li; Gang Liu

2012-01-01T23:59:59.000Z

278

The choice of substation electric connection circuits: a unified or an individual approach?1  

Science Journals Connector (OSTI)

Typical substation electric connection circuits, used at the present ... analyzed. Some versions of the use of substation distributor circuits for controlling electric network modes ... analyzed. Recommendations ...

V. P. Budovskii; V. V. Ushakov

2011-07-01T23:59:59.000Z

279

The Study of Substation Automation Remote Communication for Multi-granularity Access Control System  

Science Journals Connector (OSTI)

This paper based on the demands of access control of substation automation system, analyzed two operation objects of ... can fulfill the needs of access control in substation automation.

Lichun Shi; Haimei Xiao

2012-01-01T23:59:59.000Z

280

Assembly and function-test of the main circuit for a marine substation.  

E-Print Network [OSTI]

?? At the Division for Electricity at Uppsala University a new marine substation for waveenergy is being built. The marine substation is required to connect… (more)

Ferhatovic, Senad

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

A three-level buck converter to regulate a high-voltage DC-to-AC inverter  

E-Print Network [OSTI]

A three-level buck converter is designed and analyzed, and shown to be suitable as a high-voltage down converter as a pre-regulation stage for a 600 watt DC-to-AC power inverter. Topology selection for the inverter is ...

Schrock, Kenneth C

2008-01-01T23:59:59.000Z

282

Implementation of superconducting fault current limiter for flexible operation in the power substation  

Science Journals Connector (OSTI)

Abstract The concentration of large-scale power loads located in the metropolitan areas have resulted in high fault current levels during a fault thereby requiring the substation to operate in the double busbar configuration mode. However, the double busbar configuration mode results in deterioration of power system reliability and unbalanced power flow in the adjacent transmission lines which may result in issues such as overloading of lines. This paper proposes the implementation of the superconducting fault current limiter (SFCL) to be installed between the two substation busbars for a more efficient and flexible operation of the substation enabling both single and double busbar configurations depending on the system conditions for guaranteeing power system reliability as well as fault current limitations. Case studies are being performed for the effectiveness of the SFCL installation and results are compared for the cases where the substation is operating in single and double busbar mode and with and without the installation of the SFCL for fault current mitigation.

Chong Suk Song; Hansang Lee; Yoon-sung Cho; Jaewan Suh; Gilsoo Jang

2014-01-01T23:59:59.000Z

283

Analysis on heat loss characteristics of a 10 kV HTS power substation  

Science Journals Connector (OSTI)

Abstract A 10 kV High Temperature Superconducting power substation (10 kV HTS substation), supported by Chinese State 863 projects, was developed and has been running to supply power for several factories for more than two years at an industrial park of Baiyin, Gansu province in Northwest China. The system of the 10 kV HTS substation compositions, including a HTS cable, a HTS transformer, a SFCL, and a SMES, are introduced. The SMES works at liquid helium temperature and the other three apparatus operates under liquid nitrogen condition. There are mainly four types of heat losses existing in each HTS apparatus of the 10 kV HTS substation, including AC loss, Joule heat loss, conductive heat, and leak-in heat from cryostat. A small quantity of AC loss still exists due to the harmonic component of the current when it carries DC for HTS apparatus. The principle and basis for analysis of the heat losses are introduced and the total heat loss of each apparatus are calculated or estimated, which agree well with the test result. The analysis and result presented are of importance for the design of the refrigeration system.

Yuping Teng; Shaotao Dai; Naihao Song; Jingye Zhang; Zhiyuan Gao; Zhiqin Zhu; Weiwei Zhou; Zhourong Wei; Liangzhen Lin; Liye Xiao

2014-01-01T23:59:59.000Z

284

Progress Report, Substation No. 8, Lubbock, Texas, 1909-1914.  

E-Print Network [OSTI]

TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 219 SEPTEMBER, 1917 PROGRESS REPORT, SUBSTATION NO. 8, LUBBOCK, TEXAS B. YOUNGBLOOD, DIR.ECTOR COLLEGE STATION, BRAZOS COUNTY, TEXAS, AGRICULTURAL AND MECHANICAL COLLEGE OF TEXA W. B. BIZZELL... STATION COMMITTEE L. J. HART, Chairman 'WILL A. MILLER, JR. GOVERNING BOARD, STATE SUBSTATIONS P. L Downs President Temple ........ .............................................................................Term CHA ~LES RO~AN, Vice >resident,. AU...

Karper, R. E. (Robert Earl)

1917-01-01T23:59:59.000Z

285

Progress Report of Substation No. 12, Chillicothe, Texas, 1905- 1914.  

E-Print Network [OSTI]

TEXAS AGRICULTURAL EXPERIMENT STATION L BULLETIN NO. 202 DECEMBER, 1916 PROGRESS REPORT OF SUBSTATION NO. 1 2, CHILLICOTHE, TEXAS R. W. EDWARDS, B. S., SUPERINTENDENT POSTOFFICE : COLLEGE STATION, BRAZOS COUNTY, TEXAS. - AUSTIN, TEXAS... ................................................................................................ Term expires 1921 MAIN STATION COMMITTEE L. J. HART; Chairman J. S. WILLIAMS W. A. 'MILLER, Jr- GOVERNING BOARD, STATE SUBSTATIONS p L DOWNS President Temple ............................................................................... Term...

Edwards, R.W.

1916-01-01T23:59:59.000Z

286

Progress Report, Substation No. 9, Pecos, Texas, 1910-1914.  

E-Print Network [OSTI]

TEXAS AGRICULTURAL EXPERIMENT STATION * BULLETIN NO. 221 NOVEMBER, 19 17 -- -- PROGR.ESS REPORT, SUBSTATION NO. 9, PECOS, TEXAS COLLEGE STATION, RRAZOS COUNTY, TEXAS. AUSTIN, TEXAS : VON BOECKMANN-JONES CO., PRINTERS, 1917 AGRICULTURAL...% .................................................................................................... F. M. LAW, Houston em expires 1923 MAIN STATION COMMITTEE L. J. HART. Chairman WILL A. MILLER, JR GOVERNING BOARD, STATE SUBSTATIONS p L DOWNS, Temple. President...

Jackson, J.W.

1917-01-01T23:59:59.000Z

287

Experiments at Substation No. 3 Angleton, Texas 1909-1916.  

E-Print Network [OSTI]

~OLLEGE OF TEXAS LTBM~~~-~~~ AS AGRICULTURAL EXPERIMENT STATION - BULLE~JN NO. 229 MAY, 1918 -- EXPERIMENTS AT SUBSTATION NO. 3 ANGLETON, TEXAS B. Y OUNGBLO OD, DIRECTOR OOUEGE STATION, BRAZOS COUNTY, TEXAS. ' "RICULTURAL AND MECHANICAL... SUBSTATIONS P.'L. Downs, President, Temple ............................................................................. Term expires 191< CHARLES ROGAN, Vlce Presldenf, Austin.. ............................................................... Term expires...

Winters, N. E. (Nathaniel Elmer)

1918-01-01T23:59:59.000Z

288

Progress Report Substation No. 5, Temple, Texas, 1910-1914.  

E-Print Network [OSTI]

TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 2 15 - MAY, 1917 PROGRESS REPORT, SUBSTATION NO. 5, TEMPLE, TEXAS . B. YOUNGBLOOD, DIRECTOR COLLEGE STATION, RRAZOS COUNTY, TEXAS. AGRICULTURAL AND MECHANICAL COLL ECE OF TEXAS W. B. BIZZELL... ............................................................................................... Term explres 192: MAIN STATION COMMITTEE L. J. HART, Chairman WILL A. MILLER, JR GOVERNING BOARD, STATE SUBSTATIONS P. L. DOWNS. Temple, President .................................................................................. Term expires 1911...

Killough, D.T. (David Thornton)

1917-01-01T23:59:59.000Z

289

Evaluating Security Algorithms in the Substation Communication Architecture  

Science Journals Connector (OSTI)

Security becomes the major concern in a modernized electricity network. The IEC 61850 standard has been developed for substation automation, providing more enhancing communication functionalities. The standard defines several kinds of messages for data ... Keywords: IEC 61850, Substation Security, Message authentication, integrity

Sugwon Hong; Dae-Yong Shin; Myongho Lee

2009-09-01T23:59:59.000Z

290

Leveraging the LEDA high voltage power supply systems for the LANSCE refurbishment project  

SciTech Connect (OSTI)

The LANSCE Refurbishment Project (LANSCE-R) will revitalize the LANSCE accelerator infrastructure. Much of the equipment has been in use for over 39 years and is approaching the end of its design lifetime. As obsolescence issues make like-for-like replacements increasingly more expensive, modern systems with lower costs become a reasonable alternative. As part of the LANSCE-R project, four of the seven HV power supplies for the 805 MHz RF klystrons will be replaced. The present and future requirements for these power supplies influence the selection of replacement options. Details of the HV power supply replacement requirements and the different replacement options will be discussed. One option is to use four 95 kV, 21 A DC power supplies originally installed nearby as part of the Low Energy Demonstration Accelerator (LEDA) project. Significant material and labor cost savings can be achieved by leaving these supplies installed where they are and building a HV transport system to bring high voltage power from the existing LEDA facility to the LANSCE facility. The different replacement options will be compared based on material and labor costs as offset by long-term energy savings.

Bradley Iii, Joseph Thomas [Los Alamos National Laboratory; Rees, Daniel E [Los Alamos National Laboratory; Roybal, William T [Los Alamos National Laboratory; Young, Karen A [Los Alamos National Laboratory

2008-01-01T23:59:59.000Z

291

Redesign of the H-Bridge Switch Plate of the SNS High Voltage Converter Modulator  

SciTech Connect (OSTI)

The 1-MW High Voltage Converter Modulators [1] have operated in excess of 250,000 hours at the Spallation Neutron Source. Increased demands on the accelerator performance require increased modulator reliability. An effort is underway at SLAC National Accelerator Laboratory to redesign the modulator H-bridge switch plate with the goals of increasing reliability and performance [2]. The major difference between the SLAC design and the existing design is the use of press-pack IGBTs. Compared to other packaging options, these IGBTs have been shown to have increased performance in pulsed-power applications, have increased cooling capability, and do not fragment and disassemble during a fault event. An overview of the SLAC switch plate redesign is presented. Design steps including electrical modeling of the modulator and H-bridge, development of an integrated IGBT clamping mechanism, and fault tests are discussed. Experimental results will be presented comparing electrical performance of the SLAC switch plate to the existing switchplate under normal and fault conditions.

Kemp, M.A.; Burkhart, C.; Nguyen, M.N.; /SLAC; Anderson, D.E.; /Oak Ridge

2009-05-07T23:59:59.000Z

292

Monitoring the magnetic field in houses under 50 Hz high-voltage overhead transmission lines  

Science Journals Connector (OSTI)

This paper deals with a one-week monitoring of the 50 Hz magnetic field on the ground floor and the first floor of houses under 150, 220 and 380 kV high-voltage overhead three-phase AC transmission lines. The field strength varied with the current intensity, the conductor height, and the storey of the house. Because current intensity varies with time the magnetic field depended on the time of day and the day of the week. The recorded magnetic field ranged from 0.1 µT to 4.5 µT. The maximum value was at least 20 times weaker than the 100 µT exposure level recommended by the guidelines of the International Radiation Protection Association (IRPA) and about 140 times smaller than the 640 µT of the European Prestandard (CENELEC). The B-field was, for 99.9% of the measuring time, larger than the 0.2 µT cut-off point used to define categories of exposed and unexposed subjects in EMF epidemiological studies and, for 99.3% of the time, was greater than the 0.3 µT level used by US private engineering companies as the 'prudent avoidance' exposure limit. The weakest average magnetic field was at least 40 times larger than the 0.02 µT background value.

G. Decat; J. Van Tongerloo

1998-01-01T23:59:59.000Z

293

Electron Energy Analysis of Vacuum Discharge in High-Voltage Accelerator Tube  

Science Journals Connector (OSTI)

......measurement of the electron energy spectrum during discharge adds some new knowledge to the total voltage...authors sincerely thank Electron Energy Analysis of Vacuum Discharge...Physics, Academic Press, New York, Vol. 6, p. 297. 25......

Akio TAKAOKA; Katsumi URA; Kiyokazu YOSHIDA

1982-01-01T23:59:59.000Z

294

Finite element analysis of substation composite insulators  

Science Journals Connector (OSTI)

Composite insulators are rapidly replacing their porcelain counterparts in electrical substation applications. These insulators consist of a glass-reinforced polymer (GRP) rod, with two metal end fittings radially crimped onto the ends of the rod during assembly. In this paper, axisymmetric finite element models are developed to evaluate the mechanical performance of composite insulators under externally applied axial compression. The analyses are performed by assuming both a perfectly bonded interface between the composite rod and the end fittings, and an imperfect interface which permits large relative sliding with Coulomb friction. Results indicate that the perfect interface model is unrealistic since it predicts singular stresses at the interface comer and an overall linear structural response. On the other hand, the imperfect interface model is found to simulate accurately the structural non-linearity caused by relative sliding of the GRP rod within the end fittings. The imperfect interface model has therefore been used to evaluate the effects of interface friction, and the extent of crimping, on the maximum load-bearing capacity of substation composite insulators.

A. Bansal; A. Schubert; M.V. Balakrishnan; M. Kumosa

1995-01-01T23:59:59.000Z

295

Grizzly Substation Fiber Optics : Environmental Assessment.  

SciTech Connect (OSTI)

This notice announces BPA`s decision to construct, operate, and maintain the Grizzly Substation Fiber Optic Project (Project). This Project is part of a continuing effort by BPA to complete a regionwide upgrade of its existing telecommunications system. The US Forest Service and BPA jointly prepared the Grizzly Substation Fiber Optic Project Environmental Assessment (EA) (DOE/EA-1241) evaluating the potential environmental impacts of the Proposed Action, the Underground Installation Alternative, and the No Action Alternative. Based on the analysis in the EA, the US Forest Service and BPA have determined that the Proposed Action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act (NEPA) of 1969. Therefore, the preparation of an Environmental Impact Statement (EIS) is not required and BPA is issuing this FONSI. The US Forest Service has separately issued a FONSI and Decision Notice authorizing BPA to construct, operate, and maintain the Project within the Crooked River National Grassland (Grassland).

United States. Bonneville Power Administration.

1998-02-01T23:59:59.000Z

296

BRIEFINGS ON PHYSICAL SECURITY OF ELECTRICITY SUBSTATIONS - SAN JOSE, CA  

Broader source: Energy.gov (indexed) [DOE]

BRIEFINGS ON PHYSICAL SECURITY OF ELECTRICITY SUBSTATIONS - SAN BRIEFINGS ON PHYSICAL SECURITY OF ELECTRICITY SUBSTATIONS - SAN JOSE, CA BRIEFINGS ON PHYSICAL SECURITY OF ELECTRICITY SUBSTATIONS - SAN JOSE, CA Briefings on Physical Security of Electricity Substations The Department of Energy (DOE) and Department of Homeland Security (DHS), in coordination with the Federal Bureau of Investigation, the Federal Energy Regulatory Commission's Office of Energy Infrastructure Security, the Electricity Sector Information Sharing and Analysis Center (ES-ISAC), North American Electricity Reliability Corporation (NERC), and industry experts, will conduct a series of briefings across the country with electricity sector owners and operators, and local law enforcement on the physical security of electricity substations. The session for FEMA Region IX will be held in San Jose, CA and hosted by

297

RECORD OF CATEGORICAL EXCLUSION DETERMINATION Hygiene Substation Access Road Repairs  

Broader source: Energy.gov (indexed) [DOE]

Hygiene Substation Access Road Repairs Hygiene Substation Access Road Repairs A. Brief Description of Proposal: Western Area Power Administration proposes to repair the access road/driveway into the Hygiene Substation. There is a low spot in the middle of the driveway that impedes maneuvering oflarge maintenance equipment in and out of the yard. Western plans to fill the low spot with road base and crumbled concrete fill. The Hygiene Substation is located in Boulder County, approximately 2 miles northwest of Longmont, CO (T3N, R69W, Sec 18). All proposed construction will occur within the existing, disturbed substation access road/driveway. B. Number and Title of tile Categorical Exclusion Being Applied: (See text in 10 CFR 1021, Subpart D.) BI.3 Routine maintenance activities and custodial services for buildings, structures,

298

Scalable High-Power Redox Capacitors with Aligned Nanoforests of Crystalline MnO2 Nanorods by High Voltage Electrophoretic Deposition  

Science Journals Connector (OSTI)

Scalable High-Power Redox Capacitors with Aligned Nanoforests of Crystalline MnO2 Nanorods by High Voltage Electrophoretic Deposition ... The scalable nanomanufacturing process is demonstrated by roll-printing an aligned forest of ?-MnO2 nanorods on a large flexible substrate (1 inch by 1 foot). ...

Sunand Santhanagopalan; Anirudh Balram; Dennis Desheng Meng

2013-02-01T23:59:59.000Z

299

High voltage capability electrical coils insulated with materials containing SF.sub.6 gas  

DOE Patents [OSTI]

A coil is made having a plurality of layers of adjacent metal conductor windings subject to voltage stress, where the windings have insulation therebetween containing a small number of minute disposed throughout its cross-section, where the voids are voids filled with SF.sub.6 gas to substitute for air or other gaseous materials in from about 60% to about 95% of the cross-sectional void volume in the insulation, thus incorporating an amount of SF.sub.6 gas in the cross-section of the insulation effective to substantially increase corona inception voltages.

Lanoue, Thomas J. (Muncie, IN); Zeise, Clarence L. (Penn Township, Allegheny County, PA); Wagenaar, Loren (Muncie, IN); Westervelt, Dean C. (Acme, PA)

1988-01-01T23:59:59.000Z

300

Room-temperature atmospheric argon plasma jet sustained with submicrosecond high-voltage pulses  

SciTech Connect (OSTI)

In this letter, an experimental study is presented to characterize a room-temperature plasma jet in atmospheric argon generated with submicrosecond voltage pulses at 4 kHz. Distinct from sinusoidally produced argon discharges that are prone to thermal runaway instabilities, the pulsed atmospheric argon plasma jet is stable and cold with an electron density 3.9 times greater than that in a comparable sinusoidal jet. Its optical emission is also much stronger. Electrical measurement suggests that the discharge event is preceded with a prebreakdown phase and its plasma stability is facilitated by the short voltage pulses.

Walsh, J. L.; Kong, M. G. [Department of Electronic and Electrical Engineering, Loughborough University, Loughborough, Leicestershire LE11 3TU (United Kingdom)

2007-11-26T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Some Features of an Electrostatic Generator and Ion Source for High Voltage Research  

Science Journals Connector (OSTI)

A compact generator of the Van de Graaff type is described in which several new features have been incorporated. Short-circuit current of one milliampere is available. When operating at 600 kv as voltage supply for accelerating protons or deutersons, 130?a of charged particles at the target have been obtained from an unusual low voltage capillary arc source. In normal operation as a neutron generator, the equivalent of 15 curies of radon-beryllium is readily produced by the reaction Li+D, and 60 curies by the D on D reaction.

I. A. Getting; J. B. Fisk; H. G. Vogt

1939-12-01T23:59:59.000Z

302

Impact of High Wind Penetration on the Voltage Profile of Distribution Systems  

E-Print Network [OSTI]

that the inclusion of squirrel cage induction generator (SCIG) does not have a large influence on transient stability to the inability of induction generator to support the reactive power. So, the main objective of this study generation on the voltage profile in distribution systems have been presented. The analysis is carried out

Pota, Himanshu Roy

303

Plasma Immersion Ion Implantation with a 4kV/10kHz Compact High Voltage Pulser  

SciTech Connect (OSTI)

Development of a 4 kV/10 kHz Compact High Voltage Pulser and its application to nitrogen plasma immersion ion implantation (PIII) of different materials as Si, Al alloys, SS304 stainless steel and Ti alloys are discussed. Low voltage (1-5 kV) pulses at high frequencies (up to 20 kHz for 2 kV) were obtained with maximum power delivered at 5 kV, 7 kHz. These conditions were not sufficient to reach temperatures above 200 deg. C in the samples because of short duration of the pulses. However, very shallow implantations of nitrogen in Si, Al5052, SS304 were observed by Auger electron spectroscopy and improved corrosion resistance was obtained for Al5052 when it was treated by nitrogen PIII at 2.5 kV, 5{mu}s and 5 kHz pulses.

Ueda, M.; Oliveira, R. M.; Rossi, J. O. [Associated Laboratory of Plasma, National Institute for Space Research, Av. dos Astronautas 1758, Sao Jose dos Campos, Sao Paulo (Brazil); Reuther, H. [Institute of Ion Beam Physics and Materials Research, Rossendorf, Dresden (Germany); Silva, G. [Associated Laboratory of Plasma, National Institute for Space Research, Av. dos Astronautas 1758, Sao Jose dos Campos, Sao Paulo (Brazil); Department of Aeronautics and Mechanics, Technological Institute of Aeronautics, Sao Jose dos Campos, Sao Paulo (Brazil)

2006-11-13T23:59:59.000Z

304

Using Dielectric Losses to De-Ice Power Transmission Lines with 100 kHz High-Voltage  

E-Print Network [OSTI]

capable of exciting a 1 m test line to 30 kV has been tested and show to be capable of removing a 7 mm iceUsing Dielectric Losses to De-Ice Power Transmission Lines with 100 kHz High-Voltage Excitation J DIELECTRIC LOSSES TO DE-ICE POWER TRANSMISSION LINES . . . 1 Using Dielectric Losses to De-Ice Power

305

Substation in Clark County, Nevada RECORD OF CATEGORICAL EXCLUSION DETERMINATION  

Broader source: Energy.gov (indexed) [DOE]

Substation for soil remediation. Substation for soil remediation. The attached map shows the borrow area which is situated in Sections 18, 19,20 Township 18 South Range 64 East, Mount Diablo Meridian, Clark County, Nevada. The corresponding U.S.G.S. 7.S-minute topographic maps are Apex, Dry Lake, Dry Lake NW, and Dry Lake SE, Nevada. B. Categorical Exclusion Applied: 10 CFR, Part 1021, Subpart D, Appendix B, B4.11: "Construction of electric power substations with power delivery at 230kV or below or modification of existing sUbstations." C. Regulatory Requirements in 10 CFR 1021.410 Ib): 1. The proposed action fits within a class of actions that is listed in Appendix B to Subpart D. a. The proposed action was reviewed for the requirements of the Endangered Species Act, the National Environmental Policy Act (NEPA), the National

306

Substation in Clark County, Nevada RECORD OF CATEGORICAL EXCLUSION DETERMINATION  

Broader source: Energy.gov (indexed) [DOE]

SUbstation for soil remediation. SUbstation for soil remediation. The attached map shows the borrow area which is situated in Sections 18, 19,20 Township 18 South Range 64 East, Mount Diablo Meridian, Clark County, Nevada. The corresponding U.S.G.S. 7.5-minute topographic maps are Apex, Dry Lake, Dry Lake NW, and Dry Lake SE, Nevada. B. Categorical Exclusion Applied: 10 CFR, Part 1021, Subpart D, Appendix B, B4.11: "Construction of electric power substations with power delivery at 230kV or below or modification of existing SUbstations." C. Regulatory Requirements in 10 CFR 1021.410 (b): 1. The proposed action fits within a class of actions that is listed in Appendix B to Subpart D. a. The proposed action was reviewed for the requirements of the Endangered Species Act, the National Environmental Policy Act (NEPA), the National

307

Proposed Transmission Towers Proposed New Substation Sites Proposed...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

6-1E: Recreation Inset Maps for Map 6-1C and Map 6-1D Proposed Transmission Towers Proposed New Substation Sites Proposed Route Segments (not drawn to scale) New Access Roads...

308

Gas-Insulated Substation Performance in Brazilian System  

Science Journals Connector (OSTI)

This work is based on a report developed in the Working Group 23–03 of CIGRÉ-Brazil [1], about gas-insulated substations performance in the Brazilian electric system from...

H. J. A. Martins; V. R. Fernandes; R. S. Jacobsen

1991-01-01T23:59:59.000Z

309

APS team works smarter, cuts substation construction costs by 36%  

SciTech Connect (OSTI)

An aggressive, cost-cutting, team of T D employees at Arizona Public Service Co (APS) is building a new distribution substation in Phoenix for less than half the original cost that APS planners had calculated for the project's land, labor and materials. Scheduled for service in June of this year, APS analysts had originally projected land, labor and materials costs for the 20-MVA Bell substation at nearly $1.7-million-not including major equipment such as transformers, circuit breakers, and switches. However, after studying the project, an empowered APS crew was able to slash 36% off the original estimate-more than $610,000. What's more, APS spokesmen say that its new approach to substation construction and design has given its engineers and construction crews a laundry list of additional ideas to try out on future substation ventures. 4 figs., 1 tab.

Not Available

1993-05-01T23:59:59.000Z

310

Progress Report, Substation No. 2, Troup, Texas, 1901-1914.  

E-Print Network [OSTI]

TEXAS AGRICULTURAL EXPERIMENT STATlQl -- BULLETIN NO. 209 JANUARY, 1917 -- --- PROGRESS REPORT, SUBSTATION NO. 2, TROUP, TEXAS B. YOUNGBLOOD, DIRECTOR, COLLEGE STATION, BRAZOS COUNTY, TEXAS. [Blank Page in Original Bulletin] I TEXAS... AGRICULTURAL EXPERIMENT STATION -- BULLETIN NO. 209 JANUARY, 1917 - PROGRESS REPORT, SUBSTATION NO., 2, TROUP,. TEXAS W. S. HOTCHKISS, . Superintendent B. YOTJVGBLOOD, DIRE:CTOR, COLLEGE STATION, RRAZOS COUNTY, TEXAS. - - fl AUSTIN, TEXAS VO K...

Hotchkiss, W.S.

1917-01-01T23:59:59.000Z

311

Progress Report Substation No. 1, Beeville, Texas, 1910-1914.  

E-Print Network [OSTI]

TEXAS AGRICULTURAL EXPERIMENT STATION -- BULLETIN NO. 2 14 APRIL, 1917 .PROGRESS REPORT, SUBSTATION NO. 1, BEEVILLE, TEXAS B. YOUNGBLOOD, ,If. S., DIRECTOR COLLEGE STATION, BRAZOS COUNTY, TEXAS. [Blank Page in Original Bulletin] TEXAS....'AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 214 APRIL, 1917 PROGRESS REPORT, SUBSTATION NO. 1, BEEVILLE, TEXAS 1910-1914 E. E. BINFORD, B. S., Superintendent B. YOUNGBLOOD, $1. S., DIRI~CTOR COLLEGE STATION, BRAZOS COUNTY, TEXM. em- AUSTIN, TEXAS : VON...

Binford, E.E.

1917-01-01T23:59:59.000Z

312

Progress Report Substation No.7, Spur, Texas, 1909-1914.  

E-Print Network [OSTI]

TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 2 18 SEPTEMBER, 1917 PROGRESS REPORT, SUBSTATION NO. 7, SPUR, TEXAS . , B. YOUNGBLOOD, DIRECTOR, COLLEGE STATION, BRAZOS COUNTY, TEXAS. AunlLuL I UKAL AIVD-~LIIAITYILAL LULLEECVPTE~A~ W. B.... ............................................... .Term expires 1923 F. M. LAW, Housto11.. ................................................. .Term expires 1923 MAIN STATION COMMITTEE L. J. HART. Chairman WILL A. MILLER, JR. GOVERNING BOARD, STATE SUBSTATIONS p. L. DOWNS, President, Temple...

Dickson, R.E.

1917-01-01T23:59:59.000Z

313

Corn Variety Experiments, Substation no. 3, Angleton, Texas.  

E-Print Network [OSTI]

XAS AGRICULl'URAL EXPERIMENT STATION ~ AGRICULTURAL AND MECHANICAL COLLEGE OF TEXAS W. B. BIZZELL. Preddent . FEBRUARY, 1921 DIVISION OF AGRONOMY CORN VARIETY EXPERIMENTS SUBSTATION NO. 3, t B. YOUNGBLOOD, DIRECTOR, %LLEOE STATION, BRAZOS... Assistant SOIL SURVEY **W. T. CARTER, JR., B. S.! Chiej T. M. BUSANELL, B: S., Sorl S~ruevot H. W. HAWKER. Sorl Surueuor No. I. Denton Denton County C. H. MCDO\\;ELL. B. S.. Superintenden( SUBSTATIONS No. 7. Spar, Dickene County R. E. DICKSON. B. S...

Reynolds, E. B. (Elbert Brunner)

1921-01-01T23:59:59.000Z

314

Sweet Potato Fertilizer Experiments at Substation No. 2, Troup.  

E-Print Network [OSTI]

TEXAS AGRICULTURAL EXPERIMENT STATION AGRICULTURAL AND MECHANICAL COLLEGE OF TEXAS W. B. BIZZELL, President BULLETIN NO. 277 MARCH, 1921 SWEET POTATO FERTILIZER EXPERIMENTS AT SUBSTATION NO. 2; TROUP B. YOUNGBLOOD, DIRECTOR tmLLIU)E BTATION.... Pecos, Reeves County V. L. CORY, B. S., Superintendent No. 10. College Station, Rrazas County (Feedlng and Breedlng Substation) L. J. MCCALL, Superintendent No. 11. Nacogdoches, Nacogdoches County G. T. McN~ss, Superintendent **No. 12. Chillicothe...

Hotchkiss, W. S.

1921-01-01T23:59:59.000Z

315

PP&L experience with substation reliability centered maintenance  

SciTech Connect (OSTI)

This paper is intended to present a summary of Pennsylvania Power & Light`s (PP&L) experience with substation Reliability Centered Maintenance (RCM). The purpose of this summary is to first explain the process used by PP&L to implement substation RCM, second to explain the differences that are apparent from the use of the classical RCM analysis as compared to the method used by PP&L, and third to provide several insights into the process.

Santarelli, P.D. [Pennsylvania Power & Light Company, Hazleton, PA (United States)

1996-08-01T23:59:59.000Z

316

3D MHD modelling of the glidarc behaviour of a low current high voltage DC plasma torch Journal of Physics D: Applied Physics  

E-Print Network [OSTI]

in terms of: global behaviour, arc length, mean voltage and glidarc frequency. 1. Introduction The non-thermal on magnetohydrodynamic (MHD) modelling of atmospheric pressure direct current (DC) plasma torch operating at low current3D MHD modelling of the glidarc behaviour of a low current ­ high voltage DC plasma torch Journal

Paris-Sud XI, Université de

317

Study of gas insulated substation and its comparison with air insulated substation  

Science Journals Connector (OSTI)

Abstract This paper basically evaluates the two types of substation namely AIS and GIS on the basis of the life-cycle cost method, reliability, and environmental effects. The problems of very fast transient oscillations (VFTO) faced in GIS and their possible solutions. It substantiates and supports the use of GIS over AIS with an in depth analysis. In the end, HIS (hybrid GIS) has been proposed as a solution to overcome drawbacks of both AIS and GIS and to use the advantages of both in a single system for the best results.

Raj Nagarsheth; Sushant Singh

2014-01-01T23:59:59.000Z

318

Numerical calculation of AC substation grounding systems buried in a vertical multilayered earth model by higher-order basis function  

Science Journals Connector (OSTI)

To study the accuracy of numerical simulations for an AC substation grounding problem embedded in a vertical multilayered earth model, this paper proposes a novel algorithm combining the rapidly convergent one-dimensional Galerkin's BEM with higher-order ... Keywords: Green's function, high-order basic function, vertical multilayered earth model

Zhong-Xin Li; Jian-Bin Fan; Yu Yin

2012-05-01T23:59:59.000Z

319

Optical voltage reference  

DOE Patents [OSTI]

An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

Rankin, R.; Kotter, D.

1994-04-26T23:59:59.000Z

320

Experimental investigation of dielectric barrier discharge plasma actuators driven by repetitive high-voltage nanosecond pulses with dc or low frequency sinusoidal bias  

SciTech Connect (OSTI)

Experimental studies were conducted of a flow induced in an initially quiescent room air by a single asymmetric dielectric barrier discharge driven by voltage waveforms consisting of repetitive nanosecond high-voltage pulses superimposed on dc or alternating sinusoidal or square-wave bias voltage. To characterize the pulses and to optimize their matching to the plasma, a numerical code for short pulse calculations with an arbitrary impedance load was developed. A new approach for nonintrusive diagnostics of plasma actuator induced flows in quiescent gas was proposed, consisting of three elements coupled together: the schlieren technique, burst mode of plasma actuator operation, and two-dimensional numerical fluid modeling. The force and heating rate calculated by a plasma model was used as an input to two-dimensional viscous flow solver to predict the time-dependent dielectric barrier discharge induced flow field. This approach allowed us to restore the entire two-dimensional unsteady plasma induced flow pattern as well as characteristics of the plasma induced force. Both the experiments and computations showed the same vortex flow structures induced by the actuator. Parametric studies of the vortices at different bias voltages, pulse polarities, peak pulse voltages, and pulse repetition rates were conducted experimentally. The significance of charge buildup on the dielectric surface was demonstrated. The charge buildup decreases the effective electric field in the plasma and reduces the plasma actuator performance. The accumulated surface charge can be removed by switching the bias polarity, which leads to a newly proposed voltage waveform consisting of high-voltage nanosecond repetitive pulses superimposed on a high-voltage low frequency sinusoidal voltage. Advantages of the new voltage waveform were demonstrated experimentally.

Opaits, Dmitry F.; Likhanskii, Alexandre V.; Neretti, Gabriele; Zaidi, Sohail; Shneider, Mikhail N.; Miles, Richard B. [Mechanical and Aerospace Engineering, Princeton University, Princeton, New Jersey 08544 (United States); Macheret, Sergey O. [Lockheed Martin Aeronautics Company, Palmdale, California 93599 (United States)

2008-08-15T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Video surveillance-based insulator condition monitoring analysis for substation monitoring system (SMS)  

Science Journals Connector (OSTI)

Video surveillance (VS) of electric power lines along with its accessories such as insulators has emerged as a potential alternative for the traditional practice of on-site physical detection. There has been a paradigm shift in electric substation automation using substation monitoring system (SMS). Since the damaged insulators severely affect the distribution system performance in terms of reduction in voltage as well as flow of leakage currents, therefore, the incorporation of insulator health as an augmented feature in SMS would improve the quality and reliability of power supply. By using information technology, the automation of insulator monitoring of power system is made faster to recover the fault system immediately. This paper presents a methodology for insulator condition analysis based on VS combined with wavelet coefficient differentiator (WCD) for SMS purposes. The case studies and results contained herein corroborate the efficacy of the proposed methodology to dispense with the conventional on-site physical methods, which are not only tedious, but also time-consuming.

Velaga Sreerama Murthy; D.K. Mohanta; Sumit Gupta

2011-01-01T23:59:59.000Z

322

Recommended practice for fire protection for electric generating plants and high voltage direct current converter stations. 2005 ed.  

SciTech Connect (OSTI)

The standard outlines fire safety recommendations for gas, oil, coal, and alternative fuel electric generating plants including high voltage direct current converter stations and combustion turbine units greater than 7500 hp used for electric generation. Provisions apply to both new and existing plants. The document provides fire prevention and fire protection recommendations for the: safety of construction and operating personnel; physical integrity of plant components; and continuity of plant operations. The 2005 edition includes revisions and new art that clarify existing provisions. 5 annexes.

NONE

2005-07-01T23:59:59.000Z

323

Feasibility of thyristor controlled series capacitor for distribution substation enhancements  

SciTech Connect (OSTI)

While Thyristor Controlled Series Capacitors (TCSCs) are already being used for control of transmission system power flows, the dynamic adjustment of transmission infeed impedances presents other system enhancement opportunities. In the case of the Con Edison system, distributing substation upgrades are severely constrained by limits to existing circuit breaker interrupting capabilities. Because additional transmission line infeeds cannot be provided without increasing fault current levels, a TCSC was investigated for use as a fault current limiter. In order to demonstrate proper operation in the current limiting mode, Electromagnetic Transients Program (EMTP) simulations were conducted. Three TCSC configurations are presented to illustrate that additional power can be provided during normal operation without increasing fault currents at the substation: (1) series compensation of existing 138 kV infeeds (to allow higher substation MVA uprates), (2) series compensation of new 138 kV infeeds (without fault current increases), and (3) a 13.8 kV TCSC compensated link between two substations (to allow regulated power transfer between substation buses).

Godart, T.F.; Imece, A.F.; McIver, J.C. [GE Industrial and Power Systems, Schenectady, NY (United States). Power Systems Engineering Dept.; Chebli, E.A. [Consolidated Edison Co. of NY, Inc., New York, NY (United States)

1994-12-31T23:59:59.000Z

324

Feasibility of thyristor controlled series capacitor for distribution substation enhancements  

SciTech Connect (OSTI)

While Thyristor Controlled Series Capacitors (TCSCs) are already being used for control of transmission system power flows, the dynamic adjustment of transmission infeed impedances presents other system enhancement opportunities. In the case of the Con Edison system, distribution substation upgrades are severely constrained by limits to existing circuit breaker interrupting capabilities. Because additional transmission line infeeds cannot be provided without increasing fault current levels, a TCSC was investigated for use as a fault current limiter. In order to demonstrate proper operation in the current limiting mode, Electromagnetic Transients Program (EMTP) simulations were conducted. Three TCSC configurations are presented to illustrate that additional power can be provided during normal operation without increasing fault currents at the substation: (1) series compensation of existing 138 kV infeeds (to allow higher substation MVA uprates), (2) series compensation of new 138 kV infeeds (without fault current increases), and (3) a 13.8 kV TCSC compensated link between two substations (to allow regulated power transfer between substation buses).

Godart, T.F.; Imece, A.F.; McIver, J.C. [GE Industrial and Power Systems, Schenectady, NY (United States). Power Systems Engineering Dept.] [GE Industrial and Power Systems, Schenectady, NY (United States). Power Systems Engineering Dept.; Chebli, E.A. [Consolidated Edison Co. of New York Inc., New York, NY (United States)] [Consolidated Edison Co. of New York Inc., New York, NY (United States)

1995-01-01T23:59:59.000Z

325

A high-stability scanning tunneling microscope achieved by an isolated tiny scanner with low voltage imaging capability  

SciTech Connect (OSTI)

We present a novel homebuilt scanning tunneling microscope (STM) with high quality atomic resolution. It is equipped with a small but powerful GeckoDrive piezoelectric motor which drives a miniature and detachable scanning part to implement coarse approach. The scanning part is a tiny piezoelectric tube scanner (industry type: PZT-8, whose d{sub 31} coefficient is one of the lowest) housed in a slightly bigger polished sapphire tube, which is riding on and spring clamped against the knife edges of a tungsten slot. The STM so constructed shows low back-lashing and drifting and high repeatability and immunity to external vibrations. These are confirmed by its low imaging voltages, low distortions in the spiral scanned images, and high atomic resolution quality even when the STM is placed on the ground of the fifth floor without any external or internal vibration isolation devices.

Wang, Qi; Wang, Junting; Lu, Qingyou, E-mail: qxl@ustc.edu.cn [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China) [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China); Hefei National Laboratory for Physical Sciences at Microscale, University of Science and Technology of China, Hefei, Anhui 230026 (China); Hou, Yubin [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China)] [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China)

2013-11-15T23:59:59.000Z

326

The results of systems tests of the 500 kV busbar controllable shunting reactor in the Tavricheskaya substation  

SciTech Connect (OSTI)

The results of systems tests of the 500 kV busbar magnetization-controllable shunting reactor (CSR), set up in the Tavricheskaya substation, including measurements of the quality of the electric power, the harmonic composition of the network currents of the reactor for different values of the reactive power consumed, the determination of the regulating characteristics of the reactor, the speed of response of the shunting reactor in the current and voltage stabilization modes, and also the operation of the reactor under dynamic conditions for different perturbations, are presented. The results obtained are analyzed.

Gusev, S. I. [JSC 'FSK EES' (Russian Federation); Karpov, V. N.; Kiselev, A. N.; Kochkin, V. I. [Scientific-Research Institute of Electric Power Engineering (VNIIE) - Branch of the JSC 'NTTs Elektroenergetiki', (Russian Federation)

2009-09-15T23:59:59.000Z

327

Improving the performance of stainless-steel DC high voltage photoelectron gun cathode electrodes via gas conditioning with helium or krypton  

SciTech Connect (OSTI)

Gas conditioning was shown to eliminate field emission from cathode electrodes used inside DC high voltage photoelectron guns, thus providing a reliable means to operate photoguns at higher voltages and field strengths. Measurements and simulation results indicate that gas conditioning eliminates field emission from cathode electrodes via two mechanisms: sputtering and implantation, with the benefits of implantation reversed by heating the electrode. We have studied five stainless steel electrodes (304L and 316LN) that were polished to approximately 20 nm surface roughness using diamond grit, and evaluated inside a high voltage apparatus to determine the onset of field emission as a function of voltage and field strength. The field emission characteristics of each electrode varied significantly upon the initial application of voltage but improved to nearly the same level after gas conditioning using either helium or krypton, exhibiting less than 10 pA field emission at ?225 kV bias voltage with a 50 mm cathode/anode gap, corresponding to a field strength of ~13 MV/m. Field emission could be reduced with either gas, but there were conditions related to gas choice, voltage and field strength that were more favorable than others.

Bastaninejad, Mahzad [ODU; Elmustafa, Abdelmageed [ODU; Forman, Eric I. [JLAB; Clark, James [JLAB; Covert, Steven R. [JLAB; Grames, Joseph M. [JLAB; Hansknecht, John C. [JLAB; Hernandez-Garcia, Carlos [JLAB; Poelker, Bernard [JLAB; Suleiman, Riad S. [JLAB

2014-10-01T23:59:59.000Z

328

EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild Project,  

Broader source: Energy.gov (indexed) [DOE]

3: Estes to Flatiron Substation Transmission Lines Rebuild 3: Estes to Flatiron Substation Transmission Lines Rebuild Project, Larimer County, CO EIS-0483: Estes to Flatiron Substation Transmission Lines Rebuild Project, Larimer County, CO SUMMARY DOE's Western Area Power Administration (Western) owns and operates two 16-mile, 115-kilovolt transmission lines on separate rights-of-way between Flatiron Reservoir (near Loveland, Colorado) and the town of Estes Park, Colorado. Western is preparing this EIS to evaluate the environmental impacts of a proposal to upgrade and co-locate these transmission lines, by removing one and abandoning its right-of-way, and rebuilding the other along the existing right-of-way as a double-circuit line (i.e., six conductors per pole). The USDA Forest Service, Arapaho and Roosevelt National Forest, is a cooperating agency in preparing the EIS to support

329

Microsoft Word - CX- Eugene Substation Fiber_130520.docx  

Broader source: Energy.gov (indexed) [DOE]

3 3 REPLY TO ATTN OF: KEC-4 SUBJECT: Environmental Clearance Memorandum Jonathan Toobian Project Manager - TPC-TPP-4 Proposed Action: Eugene Substation Fiber Interconnection Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B 4.7 Fiber Optic Cable Location: Eugene, Lane County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes allowing Light Speed Networks (LSN) to interconnect with its existing fiber optic network at BPA's Eugene substation in Lane County, Oregon. To interconnect to BPA's fiber network, LSN would install two new below ground fiber optic vaults within BPA's existing right-of-way. The first vault would be installed on BPA fee-owned land immediately south of the existing substation entrance, while the second vault

330

Reliability and component importance analysis of substation automation systems  

Science Journals Connector (OSTI)

This paper aims to present a comprehensive technique to quantitatively assess the reliability of substation automation systems. The technique is based on the tie-sets methodology. In order to demonstrate the application of the proposed technique, a variety of substation automation architectures is first introduced. The associated reliability block diagrams as well as the exact system reliability are then given. The impacts and the degree of importance of various components on the reliability of substation automation systems are presented. Two suitable measures of importance are selected. The first is the Birnbaum’s measure used to determine the bottleneck of the system reliability. The second measure uses criticality importance to diagnose failures and generating repair or inspection checklists.

Hamze Hajian-Hoseinabadi

2013-01-01T23:59:59.000Z

331

A complete and normalized 61850 substation (Smart Grid Project) | Open  

Open Energy Info (EERE)

complete and normalized 61850 substation (Smart Grid Project) complete and normalized 61850 substation (Smart Grid Project) Jump to: navigation, search Project Name A complete and normalized 61850 substation Country Spain Headquarters Location Madrid, Spain Coordinates 40.488735°, -3.284912° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.488735,"lon":-3.284912,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

332

Implementation and design of a communication system of an agent-based automated substation  

Science Journals Connector (OSTI)

A substation system requires that communication be transmitted reliably, ... the communication system of an agent-based automated substation is introduced. The running principle is discussed ... realization of th...

Yong-jun Lin; Yu-tao Liu; Dan-hui Zhang

2006-12-01T23:59:59.000Z

333

Concerted Interconversion between Ionic Lock Substates of the b2 Adrenergic Receptor Revealed by Microsecond  

E-Print Network [OSTI]

Concerted Interconversion between Ionic Lock Substates of the b2 Adrenergic Receptor Revealed substates (2,5). Recently solved crystallographic structures of b2-adren- ergic receptor (B2AR) have shown

334

Research on Secure Message Transmission of Smart Substation Based on GCM Algorithm  

Science Journals Connector (OSTI)

Based on IEC61850 standard smart substation system using ethernet architecture is required for ... , MMS are common messages used in smart substation , whether these messages can be transmitted ... is critical to...

BaoYi Wang; MinAn Wang; ShaoMin Zhang

2012-01-01T23:59:59.000Z

335

Electrical Substation Performability and Reliability Indicators Modelled by Non-Homogeneous Markov Chains  

Science Journals Connector (OSTI)

In the scope of operating safety in electrical substations, EDF is brought to perform reliability and ... availability computations. These computations declined on the substation performance are used to estimate ...

Agapios Platis; Nikolaos Limnios; Marc Le Du

1996-01-01T23:59:59.000Z

336

ZigBee Performance in 400 KV Air Insulated Power Substation  

Science Journals Connector (OSTI)

An experimental assessment of the impact of the electromagnetic environment of a 400 kV substation on the performance of ZigBee equipment is ... the performance of ZigBee equipment deployed in the substation with...

Qingshan Shan; I A Glover; P J Moore…

2010-01-01T23:59:59.000Z

337

Shared-network scheme of SMV and GOOSE in smart substation  

Science Journals Connector (OSTI)

The network structure of the smart substation in common use was introduced, and the ... measured value (SMV) and generic object oriented substation event (GOOSE) were analyzed, such as ... the network reliabilit...

Wenlong WANG; Minghui LIU; Xicai ZHAO…

2014-09-01T23:59:59.000Z

338

Research on Smart Substation Equipment Condition Monitoring System Based on Wireless Sensor Networks  

Science Journals Connector (OSTI)

Reference to characteristics of wireless sensor networks (WSNs) technology and the three-tier architecture of smart substation, the paper designs an on-line condition monitoring system of smart substation equipme...

Jie He; Xiaoqing Huang; Yang Yang

2012-01-01T23:59:59.000Z

339

Chromosomal effects in lymphocytes of 400 kV-substation workers  

Science Journals Connector (OSTI)

In a previous study we found an increased rate of chromosomal aberations in substation workers. To follow up this finding we ... of circuit breakers and disconnectors in 400 kV-substations. The other 19 served as...

I. Nordenson; K. Hansson Mild; U. Östman…

1988-01-01T23:59:59.000Z

340

Criteria for phase-to-phase clearances of HV substations  

SciTech Connect (OSTI)

To facilitate uprating of HV substations, the paper re-examines line-to-line insulation design criteria. The basis for existing practices and the principles of line-to-line lightning surge overvoltage stresses are reviewed. Results of a digital study for a realistic substation are presented. The conclusions show that the line-to-line stresses, as limited by surge arresters, are substantially higher than line-to-ground stresses. This represents increased requirements as compared to existing standards. However, due to low protective levels of modern arresters, substantial reduction of line-to-line clearances is still feasible.

Panek, J.; Sublich, M.; Elahi, H. (GE Industry and Utility Sales, Schenectady, NY (US))

1990-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Cotton Variety Experiments at Substation No. 2, Troup.  

E-Print Network [OSTI]

-*-:?;,*f{*;".!( pcyv-p, ., AT SUBSTATION NO. 2, ci TROUP . AGRICULTURAL A.ND MECHANICAL COLLEGE OF TEXAS T. 0. WALTON, President STATION STAFF? ADMINISTRATION : A. B. CONNER, M. S., Director R E KARPER M S Vice-Director CLAR'ICE MIXAN 'B"A Secretary M P.... S. Department of Agriculture. ***In cooperation wlth the School of Agr~culture. icine. In tests conducted with 205 varieties and strains of cotton t Substation No. 2, Troup, during the 16 years, 1913 to 1928, ~clusive, Half and Half...

Hotchkiss, W. S.; Johnson, P. R. (Paul Rufus)

1930-01-01T23:59:59.000Z

342

Report of Experiments at Substation No. 12, Chillicothe, Texas.  

E-Print Network [OSTI]

TEXAS AGRICULTURAL EXPERIMENT STATION AGRICULTURAL AND MECHANICAL COLLEGE OF TEXAS W. B. BIZZELL, President BULLETIN NO. 253 NOVEMBER, 1919 heport of Exoeriments at Substation . No. 12, iliicothe, Texas B. YOUNGBLOOD, DIRECTOR aOuEoE STATION... Survegor R. G. BRTWER, B. S., Assisfanf Animal Hus- W. B. FR~NCIS, B. S., Soil Surve~or banaman SUBSTATIONS No. 1. Beevillei Bee County I. E. CLU~ART, M. S., Superinfendent N6. 2. Tromp, Smith County W. S. HOTCHKISS, Superinfendenf No. 3. Angleton...

Edwards, R. W.

1919-01-01T23:59:59.000Z

343

Cotton Variety Experiments: Substation No. 3, Angleton, Texas  

E-Print Network [OSTI]

TEXAS AfiRlCULTURAL EXPERIMENT STATION AGRICULTURAL AND MECHANICAL COLLEGE OF TEXAS ' W. B. BIZZELL, President BULLETIN NO. 274 FEBRUARY, 1921 DIVISION OF AGRONOMY COTTON VARIETY EXPERIMENTS SUBSTATION NO. 3, ANGLETON, TEXAS B. YOUNGBLOOD..... Chief SOIL SURVEY **W. T. CARTER. JR., B, S.. Chief T. M RTJRNNELL. R. S., Soil Surve~or H. W. HAWKER. Soil Sr~rneuar SUBSTATIONS No..l. Beeville. Bee County No. 8. Lubbock. Lubbock County I. E. COWART, M. S., Superintendent H. E. KARPER. B. S...

Reynolds, E. B. (Elbert Brunner)

1921-01-01T23:59:59.000Z

344

Progress Report, Substation No. 11, Nacogdoches, Texas, 1909-1915.  

E-Print Network [OSTI]

I 2XAS AGRlCULrURAL EXPERIMENT STATION AGRICULTURAL AND MECHANICAL COLLEGE OF TEXAS W. B. BIZZELL, President BULLETIN NO. 237 NOVEMBER, 1918 Progress Report, Substation No. 1 1, Nacogdoches, Texas, 1909- 19 15 B. YOUNGBLOOD, DIRECTOR College.... T CARTER JR Chief J. F. ST~OUD. SO;[ ~;rve!,or NFAL GEARREALD Soil Survegor T. M. BUSHNELL, b. S., Soil Survey'r SUBSTATIONS No. 1. Beeville. Bee County No. 8 Lubbock Lubbock County I. E. COWART, M. S., Superintendent R'E KARPE~ B S Superintend D: L...

McNess, George Thomas

1918-01-01T23:59:59.000Z

345

Environmental Assessment of Proposed Haskill Substation and Tap Line.  

SciTech Connect (OSTI)

To solve the service problems in the Marion area, BPA is proposing to construct a new 230/24.9-kV substation to tap BPA's existing Libby-Conkelly 230-kV line (different than Hot Springs-Conkelly 230-kV line, but an equally acceptable source). Haskill Substation would be approximately one mile northeast of the town of Marion, Montana, and would serve the western portion of Flathead Electric Cooperative's service area. This report describes possible environmental impacts of the proposed action. 8 refs., 4 figs.

Not Available

1984-05-01T23:59:59.000Z

346

A short proof of the Quantum Substate Theorem  

E-Print Network [OSTI]

The Quantum Substate Theorem due to Jain, Radhakrishnan, and Sen (2009) gives us a powerful operational interpretation of the observational divergence of two quantum states, a quantity that is closely related to their relative entropy. Informally, the theorem states that if the observational divergence between two quantum states rho, sigma is small, then there is a quantum state rho' close to rho in trace norm, such that rho' when scaled down by a small factor becomes a substate of sigma. We present a new proof of this theorem. The resulting statement is stronger and its proof is both conceptually simpler and significantly shorter than the earlier proof.

Jain, Rahul

2011-01-01T23:59:59.000Z

347

Application Filling Requirements for Transmission Line and Substation  

Broader source: Energy.gov (indexed) [DOE]

Application Filling Requirements for Transmission Line and Application Filling Requirements for Transmission Line and Substation Construction Projects (Wisconsin) Application Filling Requirements for Transmission Line and Substation Construction Projects (Wisconsin) < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Wind Solar Program Info

348

Report on Experiments with Citrus Fruits at the Beeville Sub-station.  

E-Print Network [OSTI]

!TEXAS AGRICULTURAL EXPERIMENT STATIONS BULLETIN No. 148. MAY, 1912. Report on Experiments With Citrus Fruits at The Bee- ville Sub-station A. T. POTTS, Superintendent Beeville Sub-station AUSTIN PRINTING COMPANY AUSTIN. TEXAS TEXAS... EXPERIMENT STATIONS. GOVERNING BOARD. 1 DIRECTOR OF STATIONS. ...................................... B. YOUNOBLOOD, M. S.. .College Station I SUPERINTENDENTS OF SUB-STATIONS. .................. E. E. BINFORD, Beeville Sub-station.. .Beeville, P:.e Cc...

Potts, A. T. (Arthur Tillman)

1912-01-01T23:59:59.000Z

349

Myoglobin-CO Conformational Substate Dynamics: 2D Vibrational Echoes and MD Simulations  

E-Print Network [OSTI]

Myoglobin-CO Conformational Substate Dynamics: 2D Vibrational Echoes and MD Simulations Kusai A over a range of temperatures. The A1 and A3 conformational substates of MbCO are found to have assignments for the MbCO conformational substates. INTRODUCTION Protein dynamics have been the focus of both

Fayer, Michael D.

350

Short proofs of the Quantum Substate Theorem Rahul Jain and Ashwin Nayak  

E-Print Network [OSTI]

1 Short proofs of the Quantum Substate Theorem Rahul Jain and Ashwin Nayak Abstract--The Quantum Substate Theorem due to Jain, Rad- hakrishnan, and Sen (2002) gives us a powerful operational, such that when scaled down by a small factor becomes a substate of . We present new proofs of this theorem

Jain, Rahul

351

Design Considerations for a Large-Scale Wireless Sensor Network for Substation Monitoring  

E-Print Network [OSTI]

Design Considerations for a Large-Scale Wireless Sensor Network for Substation Monitoring Asis University City Blvd. Charlotte, NC 28223 Luke Van der Zel and Bienvenido Rodriguez Substations Group EPRI-Transmissions & Substations 9625 Research Drive Charlotte, NC 28262 Ralph McKosky Technology Innovation, Environment

Nasipuri, Asis

352

Preprint of the paper "A Boundary Element Numerical Approach for Substation Grounding in a Two  

E-Print Network [OSTI]

Preprint of the paper "A Boundary Element Numerical Approach for Substation Grounding in a Two://caminos.udc.es/gmni #12;A BOUNDARY ELEMENT NUMERICAL APPROACH FOR SUBSTATION GROUNDING IN A TWO LAYER EARTH STRUCTURE3~na, SPAIN SUMMARY Analysis and design of substation grounding requires computing the distribution

Colominas, Ignasi

353

An extension to IEC 61850 for solving selectivity problem in electrical substations Mohamad Haffar*,  

E-Print Network [OSTI]

An extension to IEC 61850 for solving selectivity problem in electrical substations Mohamad Haffar substations). The integration of communication networks in critical or safety applications is nowadays to the new standard IEC 61850. We also present the development of new devices in electrical substation domain

Paris-Sud XI, Université de

354

Powerline Communication System for Monitoring and Supervision of Feeder Equipments for MV Substation Automation  

E-Print Network [OSTI]

Substation Automation LiPing LU1,2 , GangYan LI1 , YeQiong SONG2 1 ­ School of Mechanical and Electronical With the deregulation of power market and for providing better services to electric consumers, the current substation into the substations by the utilities to integrate data from relays and Intelligent Electronic Devices (IEDs

Paris-Sud XI, Université de

355

Demo Abstract: Wireless Sensor Network for Substation Monitoring: Design and Deployment  

E-Print Network [OSTI]

Demo Abstract: Wireless Sensor Network for Substation Monitoring: Design and Deployment Asis-Transmissions & Substations 9625 Research Drive Charlotte, NC 28262 {lvanderz,birodriguez} @epri.com Ralph McKosky, Joseph in a substation for monitoring the health of power subsystems such as circuit breakers, trans- formers

Nasipuri, Asis

356

Preprint of the paper "A Boundary Element Formulation for the Substation Grounding Design"  

E-Print Network [OSTI]

Preprint of the paper "A Boundary Element Formulation for the Substation Grounding Design" I://caminos.udc.es/gmni #12;A BOUNDARY ELEMENT FORMULATION FOR THE SUBSTATION GROUNDING DESIGN I. Colominas, F. Navarrina A Boundary Element approach for the numerical computation of substation grounding systems is pre- sented

Colominas, Ignasi

357

Conformational Substates of Myoglobin Intermediate Resolved by Picosecond Xray Solution Scattering  

E-Print Network [OSTI]

Conformational Substates of Myoglobin Intermediate Resolved by Picosecond Xray Solution Scattering: Conformational substates of proteins are generally considered to play important roles in regulating protein with the conformational substates using picosecond X-ray solution scattering. By applying kinetic analysis considering all

Ihee, Hyotcherl

358

Noise Amplitude Distribution of Impulsive Noise from Measurements in a Power Substation  

E-Print Network [OSTI]

Noise Amplitude Distribution of Impulsive Noise from Measurements in a Power Substation Qingshan-This paper presents ultra-wide-band measurements of impulsive noise within an electricity substation compound analysis of these events is presented. Index Terms--Electricity substation, impulsive noise, noise

Atkinson, Robert C

359

The role of the digital fault recorder in the automated substation  

SciTech Connect (OSTI)

This paper addresses the role of the digital fault recorder in the automated substation. The topics of the paper include distributed architecture, the substation LAN and reduced installation costs, multiple functions, improved substation intelligence, record generation and record merging, fault summaries, master station software, and future considerations.

Brandt, J.D. [Hathaway Corp., Littleton, CO (United States)

1996-10-01T23:59:59.000Z

360

Myoglobin-CO Substate Structures and Dynamics: Multidimensional Vibrational Echoes and Molecular Dynamics  

E-Print Network [OSTI]

Myoglobin-CO Substate Structures and Dynamics: Multidimensional Vibrational Echoes and Molecular) having its imidazole nitrogen protonated (N -H). The two conformational substate structures B and R observed in the MD simulations are assigned to the spectroscopic A1 and A3 conformational substates of Mb

Fayer, Michael D.

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

New Solutions for Substation Sensing, Signal Processing and Decision Making M. Kezunovic, Fellow IEEE  

E-Print Network [OSTI]

New Solutions for Substation Sensing, Signal Processing and Decision Making M. Kezunovic, Fellow describes a new solution for integrating substation sensing, signal processing and decision making for more. Introduction The existing substation designs for sensing, signal processing and decision-making have been

362

Peak Power Bi-directional Transfer From High Speed Flywheel to Electrical Regulated Bus Voltage System  

E-Print Network [OSTI]

were performed to determine the energy transfer capabilities of a flywheel coupled high speed permanent magnet synchronous machine through the proposed system's energy storage tank. Results are presented

Szabados, Barna

363

ANUEADflM-31 Electric Power High-Voltage Transmission Lines:  

Office of Scientific and Technical Information (OSTI)

formulated fluid that is kept under high pressure. This fluid helps to dissipate the power loss heat generated by the conductors. The construction costs in 1991 dollars for...

364

Acceleration Factors for Damp-Heat and HAST with High Voltage...  

Broader source: Energy.gov (indexed) [DOE]

High PID Resistant Cross-Linked Encapsulnt Based on Polyolefin SOLAR ASCE Comparing Accelerated Testing and Outdoor Exposure Agenda for the PV Module Reliability Workshop,...

365

A High-Frequency Resonant Inverter Topology With Low-Voltage Stress  

E-Print Network [OSTI]

This paper presents a new switched-mode resonant inverter, which we term the inverter, that is well suited to operation at very high frequencies and to rapid on/off control. Features of this inverter topology include low ...

Rivas, Juan M.

366

Management and Control for Optimal Performance of the Heating Substation  

E-Print Network [OSTI]

With the development of the scale of central heating, a higher managing level is needed for the heating substation. How to economize the more energy is the first factor that managers need to consider while ensuring the comfort of the heating...

Yang, J.

2006-01-01T23:59:59.000Z

367

Acoustic modeling and simulation of an urban substation  

Science Journals Connector (OSTI)

Demographic growth has often resulted in a disorganized occupation of large urban areas. Regions which were previously empty started to be populated frequently resulting in an increasingly more common proximity between residential construction and industrial installations. As a consequence very serious environmental problems have occurred including those caused by acoustic emission from industrial installations. A common problem these days is the disturbance caused by electric substations closely positioned to residential buildings. The disregard for acoustic effects during the design stage can still be observed in some of the older substation designs particularly in areas previously far from city centers. In some countries such as Brazil a systematic acoustic evaluation of substations only started in the 1980s with the main bulk of the work still under development. This paper describes some of the joint work being carried out on noise control by the researchers of Universidade Federal de Minas Gerais and CEMIG (the state power administration). The initial definition of a series of acoustic elements followed by the discussion of the governing equations is considered. The computational implementation of the resulting model is presented aimed at the definition of the most convenient noise control strategy. Finally a few results obtained at a real substation are considered including some experimental results obtained during actual operation.

Eduardo Bauzer Medeiros; Gia Kroeff

1998-01-01T23:59:59.000Z

368

BE 400/18 kV Substation Renovation Project  

E-Print Network [OSTI]

The 400/18 kV SPS main substation was designed for the 400 GeV SPS project and was commissioned in 1974. It has been upgraded several times to form the present 400/66/18 kV SPS and LEP transmission power comprising 490 MVA and 240 MVAR installed power. The beginning of the LHC project and the obsolescence of the main elements, and consequently limited reliability, made it necessary to begin a complete renovation program. The new configuration of the substation will integrate the new compensator of reactive power efficiently into the 18 kV pulsed network. In this way the new compensator will facilitate the functioning of the pulsed network with the new loads and it will improve the performance of the electrical substation. The renovation program consists in a global reorganisation of the substation, with the total replacement of the 18 kV power equipment, a set up of new control and protection systems for the 18 kV and 400 kV section and the reconditioning of all the 400 kV equipment.

Vairo, Antonio

2001-01-01T23:59:59.000Z

369

Simulation of an Electrical Substation Using the Bond Graph Technique  

Science Journals Connector (OSTI)

Simulation and especially computer simulation, is a basic tool since it enables engineers to understand how systems work without actually needing to see them. They can learn how they work in different circumstances and optimize their design with considerably ... Keywords: simulation, electrical substations, elements, electricity, bond graph

Gregorio Romero; Jesus Felez; Joaquin Maroto; Jose Manuel Mera

2008-04-01T23:59:59.000Z

370

Reliability centered maintenance (RCM) for substations project overview  

SciTech Connect (OSTI)

An EPRI Tailored Collaboration project establishing guidelines and tools for implementing Reliability Centered Maintenance (RCM) in substations is nearing completion and final results are being presented at this Substation RCM Conference. The ultimate goal of this RCM project is to help utilities slash substation operations and maintenance costs by optimizing equipment maintenance intervals. Preventive maintenance (PM) programs typically have been developed on a component-by-component basis, relying heavily on equipment vendors` maintenance recommendations. RCM is a logical alternative to traditional PM programs. It is intelligent, common sense maintenance that is function-based rather than component-based. First developed by the airline industry in the 1960s and further developed and applied to the nuclear industry by EPRI in the 1980s, RCM ranks the importance of each function of a system, calculates the impact the loss of the function would have on the overall system, and drives the design of appropriate maintenance tasks for each function. The nuclear industry reaped savings of at least 25% by adopting RCM, and one utility that tried this approach for substation maintenance reported savings of 13% in one year.

Lyons, P.F.

1996-08-01T23:59:59.000Z

371

Achieving low return temperatures from district heating substations  

Science Journals Connector (OSTI)

Abstract District heating systems contribute with low primary energy supply in the energy system by providing heat from heat assets like combined heat and power, waste incineration, geothermal heat, wood waste, and industrial excess heat. These heat assets would otherwise be wasted or not used. Still, there are several reasons to use these assets as efficiently as possible, i.e., ability to compete, further reduced use of primary energy resources, and less environmental impact. Low supply and return temperatures in the distribution networks are important operational factors for obtaining an efficient district heating system. In order to achieve low return temperatures, customer substations and secondary heating systems must perform without temperature faults. In future fourth generation district heating systems, lower distribution temperatures will be required. To be able to have well-performing substations and customer secondary systems, continuous commissioning will be necessary to be able to detect temperature faults without any delays. It is also of great importance to be able to have quality control of eliminated faults. Automatic meter reading systems, recently introduced into district heating systems, have paved the way for developing new methods to be used in continuous commissioning of substations. This paper presents a novel method using the temperature difference signature for temperature difference fault detection and quality assurance of eliminated faults. Annual hourly datasets from 140 substations have been analysed for temperature difference faults. From these 140 substations, 14 were identified with temperature difference appearing or eliminated during the analysed year. Nine appeared during the year, indicating an annual temperature difference fault frequency of more than 6%.

Henrik Gadd; Sven Werner

2014-01-01T23:59:59.000Z

372

Sacramento Area Voltage Support Draft Environmental Impact Statement  

SciTech Connect (OSTI)

The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the ''National Environmental Policy Act'' (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

N /A

2002-11-15T23:59:59.000Z

373

Sacramento Area Voltage Support Final Environmental Impact Statement  

SciTech Connect (OSTI)

The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the National Environmental Policy Act (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: (1) Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; (2) Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and (3) Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

N /A

2003-09-19T23:59:59.000Z

374

Tetrapropyl-tetraphenyl-diindenoperylene derivative as a green absorber for high-voltage stable organic solar cells  

Science Journals Connector (OSTI)

We present small molecule organic solar cells (SMOSC) based on flat heterojunctions (FHJ) of the alternative green donor 2,3,10,11-tetrapropyl-1,4,9,12-tetraphenyl-diindeno[1,2,3-cd:1’,2’,3’-lm]perylene (P4-Ph4-DIP) and the fullerene C60. P4-Ph4-DIP absorbs in the green spectral range and thus fills the spectral gap that standard absorber materials (zinc or copper phthalocyanine for red and C60 for blue absorption) leave, thus allowing broad coverage of the sun spectrum, which is of major interest for tandem devices. The materials properties of P4-Ph4-DIP are studied, and SMOSC are characterized by current voltage, external quantum efficiency, and aging measurements. The solar cells display very high fill factors FF > 76% and open circuit voltages VOC of close to 1 V. Mismatch-corrected efficiencies of up to 1.9% are obtained. Aging measurements show that C60 in conjunction with P4-Ph4-DIP yields extremely stable devices. We observe ? 88% of the initial efficiency after 2500 h illumination at 999 mW/cm2 illumination intensity, with no observable change in short-circuit current density. Furthermore, we also show that a systematic variation of donor thickness in FHJ can be combined with transfer matrix formalism-based optical simulations and the continuity equation for excitons to reliably determine the exciton diffusion length LD. A value of 9 ± 1 nm is found for P4-Ph4-DIP.

Jan Meiss; Martin Hermenau; Wolfgang Tress; Christoph Schuenemann; Franz Selzer; Markus Hummert; Joerg Alex; Gerhard Lackner; Karl Leo; Moritz Riede

2011-04-11T23:59:59.000Z

375

VOLUME 67, NUMBER 1 PHYSICAL REVIEW LETTERS 1 JULY 1991 Optically Induced Coherence Transfer Echoes between Zeeman Substates  

E-Print Network [OSTI]

between Zeeman Substates Dieter Suter and Martin Rosatzin Institute of Quantum Electronics, Swiss Federal

Suter, Dieter

376

Epidemiologic study of Holstein dairy cow performance and reproduction near a high-voltage direct - current powerline  

SciTech Connect (OSTI)

The development and operation of a high-voltage direct-current (HVDC) transmission line in rural Minnesota generated public concern over potential adverse effects to nearby residents and their livestock. Electrical parameters near an HVDC line decline rapidly with distance, but effects on ambient space charge have been detected out to 1 mile. To identify potential adverse effects of HVDC line operation on livestock, case-control and cohort study methods were used to examine various indices of Holstein performance in relation to distance from the line and the onset of line operation. It was believed that these indices would reflect changes in physiologic function or overt health effects that might arise from the HVDC environment. High-quality performance data from existing Dairy Herd Improvement Association (DHIA) records were obtained for 97% of qualifying herds located within 10 miles of the line. The large number of animals and years of observation provided high statistical power to detect even small systematic changes in performance. No significant differences in milk production or reproductive capacity were associated with presumed exposure to the HVDC environment. The absence of measurable effects in a large sentinel animal population may have implications for the assessment of human health risks related to HVDC transmission lines.

Martin, F.B.; Bender, A.; Steuernagel, G.; Robinson, R.A.; Revsbech, R.; Sorensen, D.K.; Williamson, N.; Williams, A.

1986-01-01T23:59:59.000Z

377

Charge-pump voltage converter  

DOE Patents [OSTI]

A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

Brainard, John P. (Albuquerque, NM); Christenson, Todd R. (Albuquerque, NM)

2009-11-03T23:59:59.000Z

378

A Laves phase-body-centered cubic structural relationship determined using high voltage electron microscopy  

SciTech Connect (OSTI)

High energy electron and ion irradiation of a TiCr{sub 2} Laves compound were found previously to result in a transformation to a body-centered cubic (bcc) solid solution. In the case of electron irradiation, the precipitating bcc phase exhibits preferential crystallographic orientation with respect to the initial compound crystal for irradiation temperatures above 200 K. This article presents an analysis of the electron diffraction data gathered in the course of the electron irradiation-induced Laves phase to bcc transformation in TiCr{sub 2}. A structural relationship between the bcc and Laves compound crystal lattices is determined which can account for all observations of preferentially oriented bcc precipitates. The significance of this mechanism for transformations between bcc and the Laves phases is discussed. In addition, the possible significance for deformation mechanisms of the Laves compounds is explored.

Sinkler, W. [GKSS Forschungszentrum, Geesthacht (Germany). Inst. fuer Werkstofforschung] [GKSS Forschungszentrum, Geesthacht (Germany). Inst. fuer Werkstofforschung

1996-04-01T23:59:59.000Z

379

A High -Temperature, High-Voltage, Fast Response Time Linear Regulator in 0.8um BCD-on-SOI.  

E-Print Network [OSTI]

??The sale of hybrid electric vehicles (HEVs) has increased tenfold from the year 2001 to 2009 [1]. With this the demand for high temperature electronics… (more)

Su, Chia Hung

2010-01-01T23:59:59.000Z

380

Voltage Control Devices on the IEEE 8500 Node Test Feeder  

SciTech Connect (OSTI)

The IEEE Test Cases provide researchers with distribution system models that can be used to validate new analytic methods. The newest of these models is the 8500-node test feeder which contains multiple devices for voltage control. In addition to a substation regulator there are multiple inline regulators as well as capacitor banks. This paper will discuss the detail in which voltage control devises should be modeled when examining large distribution systems. This discussion will include issues associated with power flow analysis for a single time step as well as for time series analysis.

Schneider, Kevin P.; Fuller, Jason C.

2010-01-06T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Categorical Exclusion for Pinnacle Peak Substation PCB contaminated Electrical  

Broader source: Energy.gov (indexed) [DOE]

Categorical Exclusion for Pinnacle Peak Substation PCB contaminated Electrical Equipment Removal Project located north of Phoenix, Maricopa County, Arizona RECORD OF CATEGORICAL EXCLUSION DETERMINATION A. Proposed Action: Western proposes drain and dispose of PCB contaminated oil from two bushings, and decontaminate one· bushing and rack, break apart PCB contaminated concrete and excavate PCB contaminated soil at Pinnacle Peak Substation. Western will be use existing access roads and vehicles such as cranes, backhoes, dozers, bucket trucks, crew trucks and pickup trucks to bring personnel and equipment to the work area. This work is necessary to maintain the safety and reliability of the bulk electrical system. The project is located in Maricopa County, Arizona. The attached map shows the

382

Microsoft Word - CX-Santiam_Substation_Renovation_WEB.doc  

Broader source: Energy.gov (indexed) [DOE]

KEPR-4 KEPR-4 SUBJECT: Environmental Clearance Memorandum Noah Carlson Project Manager - NWM-4 Proposed Action: Removal of asbestos and renovation of Santiam Substation PP&A Project No.: PP&A-1566 Budget Information: Work Order # 244751 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.16 Removal of asbestos from buildings Location: Santiam substation in Linn County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: This project entails the removal of all paint from all interior wall surfaces down to bare concrete as well as the removal of the suspended ceiling (painted with the same asbestos containing paint) and lighting systems. The asbestos containing floor tile will be removed as will the asbestos

383

Effects of intentional threats to power substation control systems  

Science Journals Connector (OSTI)

Power station control and management systems represent key elements for guaranteeing the security of the power grid infrastructure. Intrinsically conceived to support the continuous provision of power in secure conditions, those systems today make intensive use of information and communication systems and are therefore exposed to related accidental and intentional cyber threats. This paper describes a simulation of cyber attacks conducted in the CESI RICERCA laboratory testbed on a prototypical substation control infrastructure with the purpose of testing their feasibility and illustrating their impact on the control system services. A set of attack scenarios targeting several subsystems has been experimented, with different simulated threat motivations and different degrees of impact on the global substation service. The paper reports some considerations about the consequences of the implemented attacks, focusing on different facets of the problem, in an effort to elucidate the full significance of the potential cyber threats.

Giovanna Dondossola; Judit Szanto; Marcelo Masera; Igor Nai Fovino

2008-01-01T23:59:59.000Z

384

Measurement system design and implementation for grid-connected marine substation  

Science Journals Connector (OSTI)

A marine substation for a grid-connected wave power plant has been designed and constructed at Uppsala University. The measurement system for the substation has been developed from basics, and the procedure is described in this article. Subsea electrical installations set high constraints on the control and data acquisition systems used, and traditional GSM networks and GPS time synchronization are difficult and inefficient. These circumstances exclude many well-proven methods to be utilized. A compactRIO-based system, with integrated real-time controller and Field-Programmable Gate Array chip, is chosen as most suitable for this task. The system is designed to meet the special requirements encountered in this unusual application, including large data sampling, grid connection control and protection systems. The system is communicating to shore via a subsea copper cable and single-pair high-speed digital subscriber line modems. The design was successful and full-fills all the system requirements. The aim of the article is to provide future researchers with a good design and implementation procedure for setting up large measurement systems.

Rickard Ekström; Venugopalan Kurupath; Olle Svensson; Mats Leijon

2013-01-01T23:59:59.000Z

385

Optimal sparing for SF6 gas insulated substations  

Science Journals Connector (OSTI)

A method is suggested to optimize the number of spare items of substation components which have to be stored at the beginning of each year throughout a planning period. This sparing policy is conceived to provide the minimum total cost consisting of investment and load curtailment costs. The method uses the Hooke and Jeeves' direct search optimization approach. The optimization method is extended to apply to typical HV/MV GIS transformer stations requiring specific reliability modeling.

J. Nahman; V. Mijailovi?

1999-01-01T23:59:59.000Z

386

Low Voltage High-SNR Pipeline Data Converters Charles Myers, Jipeng Li, Dong-Young Chang, and Un-Ku Moon  

E-Print Network [OSTI]

Low Voltage High-SNR Pipeline Data Converters Charles Myers, Jipeng Li, Dong-Young Chang, and Un pipeline data converter. This is accomplished with the removal of the S/H input stage and the use of a rail limitations. In pipeline data converters, noise reduction options such as oversampling and noise shaping

Moon, Un-Ku

387

Substation based data interpretation techniques for improved power system management  

SciTech Connect (OSTI)

There is now considerable pressure on electric utilities to operate their systems in the most efficient manner possible and to provide increased quality of service to customers. This pressure, coupled with the decreasing availability of reserve margins dictates that there is a requirement for comprehensive system operation support through, among other things, the provision of quality information relating to the behavior of the primary and secondary systems. This paper will show how the data available within modern substation control and management systems can be exploited in a cost-effective manner, through the implementation of advanced substation functions in an open systems environment. Certain functions which are presently carried out at the control center could be distributed (or partially distributed) to the substation. These functions may provide the utility staff with quality information, which can in turn be used to satisfy the objectives of increasing quality and security of supply, in addition to optimizing the utility`s information, maintenance and asset management functions.

Booth, C.; McDonald, J.R. [Univ. of Strathclyde, Glasgow (United Kingdom). Centre for Electrical Power Engineering] [Univ. of Strathclyde, Glasgow (United Kingdom). Centre for Electrical Power Engineering; Laycock, W.J.

1997-04-01T23:59:59.000Z

388

Effect of the change in the load resistance on the high voltage pulse transformer of the intense electron-beam accelerators  

SciTech Connect (OSTI)

A high voltage pulse transformer (HVPT) is usually used as a charging device for the pulse forming line (PFL) of intense electron-beam accelerators (IEBAs). Insulation of the HVPT is one of the important factors that restrict the development of the HVPT. Until now, considerable effort has been focused on minimizing high field regions to avoid insulation breakdown between windings. Characteristics of the HVPT have been widely discussed to achieve these goals, but the effects of the PFL and load resistance on HVPT are usually neglected. In this paper, a HVPT is used as a charging device for the PFL of an IEBA and the effect of the change in the load resistance on the HVPT of the IEBA is presented. When the load resistance does not match the wave impedance of the PFL, a high-frequency bipolar oscillating voltage will occur, and the amplitude of the oscillating voltage will increase with the decrease in the load resistance. The load resistance approximates to zero and the amplitude of the oscillating voltage is much higher. This makes it easier for surface flashover along the insulation materials to form and decrease the lifetime of the HVPT.

Cheng Xinbing; Liu Jinliang; Qian Baoliang; Zhang Yu; Zhang Hongbo [College of Photoelectrical Science and Engineering, National University of Defense Technology, Hunan 410073 (China)

2009-11-15T23:59:59.000Z

389

Low-voltage gyrotrons  

SciTech Connect (OSTI)

For a long time, the gyrotrons were primarily developed for electron cyclotron heating and current drive of plasmas in controlled fusion reactors where a multi-megawatt, quasi-continuous millimeter-wave power is required. In addition to this important application, there are other applications (and their number increases with time) which do not require a very high power level, but such issues as the ability to operate at low voltages and have compact devices are very important. For example, gyrotrons are of interest for a dynamic nuclear polarization, which improves the sensitivity of the nuclear magnetic resonance spectroscopy. In this paper, some issues important for operation of gyrotrons driven by low-voltage electron beams are analyzed. An emphasis is made on the efficiency of low-voltage gyrotron operation at the fundamental and higher cyclotron harmonics. These efficiencies calculated with the account for ohmic losses were, first, determined in the framework of the generalized gyrotron theory based on the cold-cavity approximation. Then, more accurate, self-consistent calculations for the fundamental and second harmonic low-voltage sub-THz gyrotron designs were carried out. Results of these calculations are presented and discussed. It is shown that operation of the fundamental and second harmonic gyrotrons with noticeable efficiencies is possible even at voltages as low as 5-10 kV. Even the third harmonic gyrotrons can operate at voltages about 15 kV, albeit with rather low efficiency (1%-2% in the submillimeter wavelength region).

Glyavin, M. Yu.; Zavolskiy, N. A.; Sedov, A. S. [Institute of Applied Physics RAS, N. Novgorod 603600 (Russian Federation); Nusinovich, G. S. [IREAP, University of Maryland, College Park, Maryland 20742-3511 (United States)

2013-03-15T23:59:59.000Z

390

A wide bandgap silicon carbide (SiC) gate driver for high-temperature and high-voltage applications  

SciTech Connect (OSTI)

Limitations of silicon (Si) based power electronic devices can be overcome with Silicon Carbide (SiC) because of its remarkable material properties. SiC is a wide bandgap semiconductor material with larger bandgap, lower leakage currents, higher breakdown electric field, and higher thermal conductivity, which promotes higher switching frequencies for high power applications, higher temperature operation, and results in higher power density devices relative to Si [1]. The proposed work is focused on design of a SiC gate driver to drive a SiC power MOSFET, on a Cree SiC process, with rise/fall times (less than 100 ns) suitable for 500 kHz to 1 MHz switching frequency applications. A process optimized gate driver topology design which is significantly different from generic Si circuit design is proposed. The ultimate goal of the project is to integrate this gate driver into a Toyota Prius plug-in hybrid electric vehicle (PHEV) charger module. The application of this high frequency charger will result in lighter, smaller, cheaper, and a more efficient power electronics system.

Lamichhane, Ranjan [University of Arkansas; Ericson, Milton Nance [ORNL; Frank, Steven Shane [ORNL; BRITTONJr., CHARLES L. [Oak Ridge National Laboratory (ORNL); Marlino, Laura D [ORNL; Mantooth, Alan [University of Arkansas; Francis, Matt [APEI, Inc.; Shepherd, Dr. Paul [University of Arkansas; Glover, Dr. Michael [University of Arkansas; Podar, Mircea [ORNL; Perez, M [University of Arkansas; Mcnutt, Tyler [APEI, Inc.; Whitaker, Mr. Bret [APEI, Inc.; Cole, Mr. Zach [APEI, Inc.

2014-01-01T23:59:59.000Z

391

Measurement of the acoustic pressure distribution occurring around an aerial substation adjacent to apartment buildings  

Science Journals Connector (OSTI)

The subject matter of the research work presented in this paper refers to the measurements of the values of the acoustic pressure levels (noise) occurring around a main feeding?point aerial substation adjacent to apartment buildings. The paper presents the values of the noise accompanying the particular power devices mainly transformers during their regular operation. The main aim of this research work was the comparison and assessment of the acoustic pressure values measured with the permissible values defined by environmental standards binding in Poland. The research analysis carried out proved that during a long?term operation of power appliances installed in substations the acoustic pressure level that they emit into the environment is not constant but is subject to changes. Thus the increase of the noise level above the permissible values can be the cause of violation of environmental standards. Due to a significant increase of people's awareness and readiness to claim their rights the main consequence of violating the standards is a growing number of claims. Therefore it is imperative that the level of the acoustic pressure be monitored during routine tests especially around high?power transformers.

Sebastian Borucki; Tomasz Boczar; Andrzej Cichon

2008-01-01T23:59:59.000Z

392

Substations for Decentralized Solar District Heating: Design, Performance and Energy Cost  

Science Journals Connector (OSTI)

Abstract The development of solar district heating is gaining more and more interest, but, in some case the space available for the integration of solar collectors on the ground is limited and the use of decentralized systems is necessary. For decentralized solar district heating systems different hydraulic schemes at the substation level, with or without local use of solar energy, are possible. The present paper detailed an advanced study on decentralized solar district heating system using dynamic simulation software. Nine different hydraulic schemes for substations have been investigated with a return to return feed in. For each scheme many parameters that influence the performance of the solar installation have been studied such as the district heating network return temperature, the solar collector area and the type of solar collector (low temperature or high temperature solar collector). The comparison between the different hydraulic schemes is based on thermal efficiency but also on solar energy cost using the methodology of the Levelized Cost Of Energy (LCOE).

Cedric Paulus; Philippe Papillon

2014-01-01T23:59:59.000Z

393

Optimal Design of Grounding System for HV / EHV Substations in Two Layered Soil  

E-Print Network [OSTI]

Abstract — Successful operation of entire power system depends to a considerable extent on efficient and satisfactory performance of substations. Hence substations in general can be considered as heart of overall power system. In any substation, a well designed grounding plays an important role. Since absence of safe and effective grounding system can result in mal-operation or non-operation of control and protective devices, grounding system design deserves considerable attention for all the substations. Grounding system has to be safe as it is directly concerned with safety of persons working within the substation. Main purpose of this work is designing safe and cost effective grounding systems for HV / EHV substations situated at such locations where soil of the substation site is not uniform. Here soil is considered to be horizontally stratified into two layers. Initially significance of two layered soil model is introduced and design methodology for design of substation grounding system is discussed. Next, two design problems have been solved by using newly developed software and results obtained here are verified with the help of Ground Grid Systems module of ETAP – professional software. Comparison of the results obtained by both the software shows nice agreement of the results given by ESGSD with those obtained from ETAP. Hence this software is found to be quite satisfactory tool in the field of design of grounding system for HV / EHV substations.

unknown authors

394

Alleviations of Substation Congestions by Distributed Generations â An Optimal Location and Reliability Analysis.  

E-Print Network [OSTI]

??With increased load demands from the customers, substation congestion problems have become inevitable to the utility companies. Instead of expanding related system installations to alleviate… (more)

Melvin, Galicia

2011-01-01T23:59:59.000Z

395

Experience in the installation of a microprocessor system for controlling converter units of the Vyborg substation  

Science Journals Connector (OSTI)

The experience in the installation of modern digital systems for controlling converter units at the Vyborg converter substation on the basis of advanced microprocessor devices...

K. B. Gusakovskii; E. Yu. Zmaznov; S. V. Katantsev…

2006-01-01T23:59:59.000Z

396

An Integrative Approach to Reliability Analysis of an IEC 61850 Digital Substation.  

E-Print Network [OSTI]

??In recent years, reliability evaluation of substation automation systems has received a significant attention from the research community. With the advent of the concept of… (more)

Zhang, Yan 1988-

2012-01-01T23:59:59.000Z

397

Design & Implementation of a Universal Communications Processor for Substation Integration, Automation and Protection.  

E-Print Network [OSTI]

??Substation Automation (SA) is a rapidly increasing area of interest in Electrical Engineering these days embracing numerous benefits to utilities. It is clearly the most… (more)

Ozansoy, Cagil Ramadan

2006-01-01T23:59:59.000Z

398

Improving Reliability of IEEE-1588 in Substation Automation Based on Clock Drift Prediction.  

E-Print Network [OSTI]

?? An electric substation is a node in the power grid network. It serves the purpose of transmitting and distributing electric energy from power sources… (more)

Xiao, Yin

2008-01-01T23:59:59.000Z

399

New testing methods and new testing tools for systems utilizing substation communication networks  

Science Journals Connector (OSTI)

The upcoming standard IEC 61850 prepares the ground for the broad application of data communication networks and systems in substations. With the new systems becoming installed,...

F. Steinhauser Dipl.-Ing. Dr. techn.

2003-12-01T23:59:59.000Z

400

Investigation of Wireless LAN for IEC 61850 based Smart Distribution Substations.  

E-Print Network [OSTI]

??The IEC 61850 standard is receiving acceptance worldwide to deploy Ethernet Local Area Networks (LANs) for electrical substations in a smart grid environment. With the… (more)

Parikh, Palak P

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

A wireless 802.11 condition monitoring sensor for electrical substation environments.  

E-Print Network [OSTI]

??The work reported in this thesis is concerned with the design, development and testing of a wireless 802.11 condition monitoring sensor for an electrical substation… (more)

Bogias, Alexander

2012-01-01T23:59:59.000Z

402

Implementation of embedded Ethernet based on hardware protocol stack in substation automation system  

Science Journals Connector (OSTI)

Embedded Ethernet technology has been utilized increasingly widely as the communication mode in the substation automation system (SAS). This paper introduces...

Qiang Ma ? ?; Jianguo Zhao ???; Bingxu Liu ???

2008-04-01T23:59:59.000Z

403

Microsoft Word - CX-HeboSubstationA- FY13_WEB.doc  

Broader source: Energy.gov (indexed) [DOE]

Todd Nicholson Supervisory Civil Engineer - TELF-TPP-3 Proposed Action: Hebo Substation Access Road Maintenance Budget Information: Work Order 00270316 PP&A Project No.: 2784...

404

Researchers map atomic movements that trigger voltage fade in...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

map atomic movements that trigger voltage fade in high-energy-density batteries January 22, 2015 Voltage and capacity curves from an LMR-NMC high-energy cathode show voltage fade...

405

Microsoft Word - CX-Covington_Substation_WEB.doc  

Broader source: Energy.gov (indexed) [DOE]

8, 2010 8, 2010 REPLY TO ATTN OF: KEPR-4 SUBJECT: Environmental Clearance Memorandum Kerry Cook Project Manager - TELF-TPP-3 Proposed Action: Perform research of groundwater drainage and flooding issues at Covington Complex through the installation of four groundwater monitoring wells PP&A Project No.: PP&A-1772 Budget Information: Work Order #00246440 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B3.6 Siting/ construction/operation/decommissioning of facilities for bench-scale research, conventional laboratory operations, small-scale research and development and pilot projects. Location: Covington Substation in King County, Washington Proposed by: Bonneville Power Administration (BPA)

406

Voltage controlled current source  

DOE Patents [OSTI]

A seven decade, voltage controlled current source is described for use in testing intermediate range nuclear instruments that covers the entire test current range of from 10 picoamperes to 100 microamperes. High accuracy is obtained throughout the entire seven decades of output current with circuitry that includes a coordinated switching scheme responsive to the input signal from a hybrid computer to control the input voltage to an antilog amplifier, and to selectively connect a resistance to the antilog amplifier output to provide a continuous output current source as a function of a preset range of input voltage. An operator controlled switch provides current adjustment for operation in either a real-time simulation test mode or a time response test mode.

Casne, Gregory M. (Pittsburgh, PA)

1992-01-01T23:59:59.000Z

407

Studies of parallelism in distribution networks served by different-source substations  

Science Journals Connector (OSTI)

Despite the fact that the distribution systems usually operate radially, there is the possibility of changing the topology by opening or closing the switching equipment [1]. This change can occur in two situations. In the first one, when one tries to optimize the configuration of the electric network, aiming to achieve lower voltage drop and loss indices, as well an increased reliability. In the second one, when one needs to transfer load from a feeder to another, as result of some contingency or a planned disconnection. In both situations, one has to take into account that multiple switchings in the networks can cause some disconnections for customers, during a short period of time, especially when the feeders are served by different-source substations. These interruptions cause undesirable energy continuity levels for customers, who are more demanding in relation to the electric power supply quality. This context has motivated this paper, whose proposal is the development of a methodology to analyze the technical feasibility of parallelisms in distribution networks by using the Alternative Transient Program (ATP), thus avoiding disconnections for customers. As a result, case studies in AES Sul's concession area, power distribution utility, will be presented.

D.P. Bernardon; L. Comassetto; F.D. Veiga; L.N. Canha

2008-01-01T23:59:59.000Z

408

Identifying surface structural changes in layered Li-excess nickel manganese oxides in high voltage lithium ion batteries: A joint experimental and theoretical study  

SciTech Connect (OSTI)

High voltage cathode materials Li-excess layered oxide compounds Li[Ni{sub x}Li{sub 1/3-2x/3}Mn{sub 2/3-x/3}]O{sub 2} (0 < x < 1/2) are investigated in a joint study combining both computational and experimental methods. The bulk and surface structures of pristine and cycled samples of Li[Ni{sub 1/5}Li{sub 1/5}Mn{sub 3/5}]O{sub 2} are characterized by synchrotron X-Ray diffraction together with aberration corrected Scanning Transmission Electron Microscopy (a-S/TEM). Electron Energy Loss Spectroscopy (EELS) is carried out to investigate the surface changes of the samples before/after electrochemical cycling. Combining first principles computational investigation with our experimental observations, a detailed lithium de-intercalation mechanism is proposed for this family of Li-excess layered oxides. The most striking characteristics in these high voltage high energy density cathode materials are (1) formation of tetrahedral lithium ions at voltage less than 4.45 V and (2) the transition metal (TM) ions migration leading to phase transformation on the surface of the materials. We show clear evidence of a new spinel-like solid phase formed on the surface of the electrode materials after high-voltage cycling. It is proposed that such surface phase transformation is one of the factors contributing to the first cycle irreversible capacity and the main reason for the intrinsic poor rate capability of these materials.

Xu, Bo; Fell, Christopher R.; Chi, Miaofang; Meng, Ying Shirley (ORNL); (Florida); (UCSD)

2011-09-06T23:59:59.000Z

409

A PC-PCL-based control system for the high-voltage pulsed-power operation of the Intense Diagnostic Neutral Beam (IDNB) Experiment  

SciTech Connect (OSTI)

A stand-alone, semiautomated control system for the high-voltage pulsed-power energy sources on the Intense Diagnostic Neutral Beam Experiment at Los Alamos National Laboratory using personal computer (PC) and programmable logic controller (PLC) technology has been developed and implemented. The control system, consisting of a PC with the graphic operator interface, the network connecting the PC to the PLC, the PLC, the PLC I/O modules, fiber-optic interfaces and software, is described.

Gribble, R.

1993-06-01T23:59:59.000Z

410

Ferroresonance Evaluation at Boushehr 230/400 kV GIS Substation of Iran’s Power Network  

Science Journals Connector (OSTI)

Ferroresonance is one of the main and important reasons to distortion equipments in GIS substations. This phenomenon is not always predictable and ... ferroresonance is necessary to analyze before designing the substation

M. Majidi; H. Javadi; M. Oskuoee

2011-01-01T23:59:59.000Z

411

A BOUNDARY ELEMENT FORMULATION FOR THE COMPUTER DESIGN OF SUBSTATION I. Colominas, F. Navarrina, and M. Casteleiro  

E-Print Network [OSTI]

A BOUNDARY ELEMENT FORMULATION FOR THE COMPUTER DESIGN OF SUBSTATION GROUNDING I. Colominas, F approach for the numerical com- putation of substation grounding systems is presented. In this general

Colominas, Ignasi

412

The Fault Diagnosis of Electric Railway Traction Substation with Model-Based Diagnosis of Integration of FDI and DX Approaches  

Science Journals Connector (OSTI)

Most diagnosis systems used in electric railway substation are expert systems based on experiences, which ... applied to diagnose the electric devices in railway substation. The system model knowledge can be obta...

Zhigang Liu; Zhiwei Han; Wei Zhong

2009-01-01T23:59:59.000Z

413

Design and costs estimation of electrical substations based on three-dimensional building blocks  

Science Journals Connector (OSTI)

Substations design is a fundamental engineering component in power network construction. The benefits obtained for having adequate tools and design systems are related mainly to cost savings, reduction of construction problems and faster throughput of ... Keywords: 3D environments, CAD tools, building blocks, electrical substations design

Eduardo Islas Pérez; Jessica Bahena Rada; Jesus Romero Lima; Mirna Molina Marín

2010-11-01T23:59:59.000Z

414

Progress Report of Substation No. 4, Beaumont, Texas, 1909-1914.  

E-Print Network [OSTI]

TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 200 DECEMBER, 1916 = PROGRESS REPORT, SUBSTATION NO. 4, BEAUMONT, TEXAS B. YOUWOBLOOD, DIRECTOR, ' COLLEGE STATION, BRAZOS COUNTY, TEXAS. TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO.... 200 DECEMBER, 191 6 PROGRESS REPORT, SUBSTATION NO. 4, BEAUMONT, TEXAS H. H. LAUDE, B. S., SUPERINTENDENT B. YOUNGBLOOD, DIRECTOR, COLLEGE STATION, BRAZOS COUNTY, TEXAS. - - AUSTIN, TEXAS : VON BOECKMANN- JONES CO., PRINTEBS, 1917...

Laude, H. H. (Hilmer Henry)

1916-01-01T23:59:59.000Z

415

Report of Progress at the Troupe Sub-Station, Smith County Texas.  

E-Print Network [OSTI]

TEXAS AGRICULTUR 146-409-lorn [PERIMENT STATIONS BULLETIN NO. 121 FEBRUARY 1, 1909 REPORT OF PROGRESS AT THE TROUPE SUB-STATION, SMITH COUNTY, TEXAS W. H. HOTCHKISS, SUPERINTENDENT IN CHARGE POSTOFFICE COLLEGE STATION, BRAZOS COUNTY.... ..................................... C. W. CRISLER. .Chief Clerk. .................................. F. R. N~VAILLE. .Stenographer. ...................................... A. S. WARE.. .Stenographer. STATE SUBSTATIONS. ..................... H. H. HARRINGTON, Director. .College...

Hotchkiss, W.S.

1909-01-01T23:59:59.000Z

416

Special design and testing aspects of the 345 kV East Fishkill substation  

SciTech Connect (OSTI)

The installation of two 135 MVAR capacitor banks in the 345 kV East Fishkill substation required special design of the grounding system, installation of reactors in series with the capacitor banks, closing resistors in the circuit breakers and special shielding of control cables. This paper describes the design of the substation and the tests performed before commissioning the capacitor banks.

Fogarty, R.P.; Halleran, T.M.; Laskowski, L.M.; Mark, D.A. (Consolidated Edison Co. of New York, Inc., New York, NY (United States))

1992-10-01T23:59:59.000Z

417

The Functional Design on Fault Recorder of µC / OS-II-based Intelligent Substation  

Science Journals Connector (OSTI)

Regarding the functional requirements for smart substation in fault recorder, this paper introduced µC / OSII, an embedded real-time multitasking operating system as the functional design. The program works with the embedded operating system, the ... Keywords: intelligent substation, fault recorder, embedded operating systems, the ?C / OS-II, state machine

Zhang Yihui; Hu Wenqiang; Liu Shiming; Wang Huabin; Zhang Haiyan

2012-04-01T23:59:59.000Z

418

Abstract--With the deregulation and restructuring of utility industry, many substation automation applications are being  

E-Print Network [OSTI]

1 Abstract--With the deregulation and restructuring of utility industry, many substation automation serves as a handy tool for substation automation related studies. Index Terms--Alternative Transient the deregulation and restructuring of utility industry, it is desirable to introduce more automated functions

419

Requirements Specification for and Evaluation of an Automated Substation Monitoring System  

E-Print Network [OSTI]

, without to much disruption in power supply to the users, Equipment Condition Monitoring (ECM) has to beRequirements Specification for and Evaluation of an Automated Substation Monitoring System Mladen for the Automated Analysis Substation System (AASS) implemented at Texas A&M University, aimed at monitoring

420

Voltage balanced multilevel voltage source converter system  

DOE Patents [OSTI]

A voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means.

Peng, Fang Zheng (Oak Ridge, TN); Lai, Jih-Sheng (Knoxville, TN)

1997-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Voltage balanced multilevel voltage source converter system  

DOE Patents [OSTI]

Disclosed is a voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means. 15 figs.

Peng, F.Z.; Lai, J.S.

1997-07-01T23:59:59.000Z

422

Silicon-on-insulator-based high-voltage, high-temperature integrated circuit gate driver for silicon carbide-based power field effect transistors  

SciTech Connect (OSTI)

Silicon carbide (SiC)-based field effect transistors (FETs) are gaining popularity as switching elements in power electronic circuits designed for high-temperature environments like hybrid electric vehicle, aircraft, well logging, geothermal power generation etc. Like any other power switches, SiC-based power devices also need gate driver circuits to interface them with the logic units. The placement of the gate driver circuit next to the power switch is optimal for minimising system complexity. Successful operation of the gate driver circuit in a harsh environment, especially with minimal or no heat sink and without liquid cooling, can increase the power-to-volume ratio as well as the power-to-weight ratio for power conversion modules such as a DC-DC converter, inverter etc. A silicon-on-insulator (SOI)-based high-voltage, high-temperature integrated circuit (IC) gate driver for SiC power FETs has been designed and fabricated using a commercially available 0.8--m, 2-poly and 3-metal bipolar-complementary metal oxide semiconductor (CMOS)-double diffused metal oxide semiconductor (DMOS) process. The prototype circuit-s maximum gate drive supply can be 40-V with peak 2.3-A sourcing/sinking current driving capability. Owing to the wide driving range, this gate driver IC can be used to drive a wide variety of SiC FET switches (both normally OFF metal oxide semiconductor field effect transistor (MOSFET) and normally ON junction field effect transistor (JFET)). The switching frequency is 20-kHz and the duty cycle can be varied from 0 to 100-. The circuit has been successfully tested with SiC power MOSFETs and JFETs without any heat sink and cooling mechanism. During these tests, SiC switches were kept at room temperature and ambient temperature of the driver circuit was increased to 200-C. The circuit underwent numerous temperature cycles with negligible performance degradation.

Tolbert, Leon M [ORNL; Huque, Mohammad A [ORNL; Blalock, Benjamin J [ORNL; Islam, Syed K [ORNL

2010-01-01T23:59:59.000Z

423

Final environmental assessment for vegetation control at VHF stations, microwave stations, electrical substations, and pole yards  

SciTech Connect (OSTI)

Southwestern Power Adm. operates very high frequency (VHF) and microwave radio stations, electrical substations, and pole yards for electric power transmission throughout AR, MO, and OK. Vegetation growth at the stations must be suppressed for safety of operation and personnel. Southwestern has been using a combination of mechanical/manual and herbicide control for this purpose; Federally- mandated reductions in staff and budgetary resources require Southwestern to evaluate all potentially efficient methods for vegetation control. Three alternatives were examined: no action, mechanical/manual control, and (proposed) a combination of mechanical/manual and herbicide control. Environmental impacts on air and water quality, wetlands, wildlife, endangered species, archaeological and other resources, farmland, human health, transportation, etc. were evaluated.

NONE

1995-10-13T23:59:59.000Z

424

Integrated polymer solar cells in serial architecture with patterned charge-transporting MoOx for miniature high-voltage sources  

Science Journals Connector (OSTI)

We develop miniature high-voltage sources from polymer solar cells (PSCs) with charge-transporting molybdenum oxide (MoOx) integrated in a serial architecture through sacrificial layer (SL)-assisted patterning. The MoOx layer, being patterned by the lift-off process of the SL of a hydrophobic fluorinated-polymer, as a hole transporting layer plays a critical role on the reduction of the dark current and the increase of a high open circuit voltage of an integrated PSC array. The underlying mechanism lies primarily on the elimination of the lateral charge pathways in the MoOx layer in the presence of the electrode interconnection. Two miniature voltage sources consisting of 20 PSCs and 50 PSCs are demonstrated in the operation of a liquid crystal display and an organic field-effect transistor, respectively. Our SL-assisted integration approach will be directly applicable for implementing the self-power sources made of the PSCs into a wide range of the electronic and optoelectronic devices.

Seong-Min Cho; Chang-Min Keum; Hea-Lim Park; Min-Hoi Kim; Jin-Hyuk Bae; Sin-Doo Lee

2014-01-01T23:59:59.000Z

425

Pulsed CO{sub 2} laser with an X-ray preioniser based on a high-voltage low-pressure glow discharge  

SciTech Connect (OSTI)

An X-ray preioniser with an electron beam energy density of 0.1 J cm{sup -2} based on a high-voltage (20 - 40 kV) low-pressure glow discharge is developed for repetitively pulsed gas lasers. The electron concentration in the CO{sub 2} - N{sub 2} - He mixture as a function of the voltage across the preioniser is calculated for titanium and other foils. The preioniser can be operated both in a single-pulse regime and at pulse repetition rates ranging up to hundreds of Hertz. A specific energy yield of 51 J L{sup -1} is achieved in the X-ray preionised pulsed CO{sub 2} atmospheric-pressure laser. This preioniser was shown to be efficient for other active media (CO and excimer lasers), which opens up new opportunities for the development of repetitively pulsed gas lasers. (lasers)

Oreshkin, V F; Seregin, Aleksandr M; Sinaiskii, V V; Shchetinkina, T A ['Astrofizika' Research and Production Association (Russian Federation); Sorokin, A R [Institute of Semiconductor Physics, Siberian Branch of the Russian Academy of Sciences, Novosibirsk (Russian Federation)

2003-12-31T23:59:59.000Z

426

Conformational Switching between Protein Substates Studied with 2D IR Vibrational Echo Spectroscopy and Molecular Dynamics Simulations  

E-Print Network [OSTI]

Conformational Switching between Protein Substates Studied with 2D IR Vibrational Echo Spectroscopy. Three conformational substates have been identified for the carbonmonoxy form of myoglobin (Mb vibrational echo chemical exchange experiments are used to observed switching between two of these substates

Fayer, Michael D.

427

IEEE TRANSACTIONS ON SPEECH AND AUDIO PROCESSING, VOL. 10, NO. 3, MARCH 2002 137 Substate Tying With Combined Parameter Training  

E-Print Network [OSTI]

IEEE TRANSACTIONS ON SPEECH AND AUDIO PROCESSING, VOL. 10, NO. 3, MARCH 2002 137 Substate Tying. To facilitate tying at the substate level, the state emission proba- bilities are constructed in two stages or exploits Gaussian density sharing and substate tying. Another approach to enhance model training

California at Santa Barbara, University of

428

Voltage Impacts of Utility-Scale Distributed Wind  

SciTech Connect (OSTI)

Although most utility-scale wind turbines in the United States are added at the transmission level in large wind power plants, distributed wind power offers an alternative that could increase the overall wind power penetration without the need for additional transmission. This report examines the distribution feeder-level voltage issues that can arise when adding utility-scale wind turbines to the distribution system. Four of the Pacific Northwest National Laboratory taxonomy feeders were examined in detail to study the voltage issues associated with adding wind turbines at different distances from the sub-station. General rules relating feeder resistance up to the point of turbine interconnection to the expected maximum voltage change levels were developed. Additional analysis examined line and transformer overvoltage conditions.

Allen, A.

2014-09-01T23:59:59.000Z

429

Optimal Voltage Control of the Southern Norwegian Power Grid.  

E-Print Network [OSTI]

??This thesis contains the synthesis, analysis and simulation results of an automatic optimal voltage controller for the Southern Norwegian power grid. Currently the high voltage… (more)

Hannisdal, Erik Lundegaard

2011-01-01T23:59:59.000Z

430

> REPLACE THIS LINE WITH YOUR PAPER IDENTIFICATION NUMBER (DOUBLE-CLICK HERE TO EDIT) < 1 Abstract--In high current, high voltage, high temperature  

E-Print Network [OSTI]

and high current applications, such as HVDC transmission [1] or pulsed power application [2], a thyristor

Paris-Sud XI, Université de

431

Daily load profile and monthly power peaks evaluation of the urban substation of the capital of Jordan Amman  

Science Journals Connector (OSTI)

The hourly recorded power of an urban substation of the National Electric Power Company (NEPCO) in the capital of Jordan Amman is used to calculate the diversity and conversion factors of the substation. These factors are used to estimate the daily load power profile and the monthly peak power of the substation. The results show that the conversion factors are almost independent of the number of feeders in the substation, while the diversity factors vary in substations that have six feeders or less. The results show a good correlation between the estimated and actual recorded data of the daily load profile with less than 5% percentage error.

Nabeel I.A. Tawalbeh

2012-01-01T23:59:59.000Z

432

Canby Area Service Project : Substation and Associated Transmission Line : Environmental Assessment.  

SciTech Connect (OSTI)

Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp's substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC's Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC's substation can accommodate only about 10 percent of the expected additional electric load. BPA's proposed action is intended to meet SVEC's increasing electric load. BPA proposes to meet SVEC's increasing energy load by tapping into BPA's existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC's Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no environmental impact statement'' is not required.

United States. Bonneville Power Administration.

1992-02-01T23:59:59.000Z

433

Canby Area Service Project substation and associated transmission line. Environmental Assessment  

SciTech Connect (OSTI)

Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp`s substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC`s Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC`s substation can accommodate only about 10 percent of the expected additional electric load. BPA`s proposed action is intended to meet SVEC`s increasing electric load. BPA proposes to meet SVEC`s increasing energy load by tapping into BPA`s existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC`s Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no ``environmental impact statement`` is not required.

Not Available

1992-02-01T23:59:59.000Z

434

Microsoft Word - Ringold Substation Upgrade CX.doc  

Broader source: Energy.gov (indexed) [DOE]

1, 2011 1, 2011 REPLY TO ATTN OF: KEC-4 SUBJECT: Environmental Clearence Memorandum Myra Lovell - TELP-TPP-3 Proposed Action: Ringold Substation Structure Replacement Project Budget Information: Work Order # 00272078 Task 03 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021: B4.6 "Additions or modifications to electric power transmission facilities..." Location: Franklin County, Washington - Township 12 North, Range 29 East, Section 26 of the Basin City Quadrangle Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA is proposing to replace the single pole structure 8/9 of the Benton-Scooteney No. 1 115-kV transmission line, the attached vertically mounted disconnect switch,

435

Microsoft Word - CX-ColumbiaREADaytonSubstationTap_WEB.doc  

Broader source: Energy.gov (indexed) [DOE]

7, 2011 7, 2011 REPLY TO ATTN OF: KEPR-4 SUBJECT: Environmental Clearance Memorandum Mike Normandeau Customer Account Executive - PSE-SPOKANE Proposed Action: Columbia Rural Electric Association (Columbia REA) Dayton Substation Tap Line Project Budget Information: Work Order 00118303, Task 17 PP&A Project No.: PP&A 2089 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.12: Construction of electric power lines approximately 10 miles in length or less that are not for the integration of major new generation resources into a main transmission system. Location: Dayton, Columbia County, Washington Township 10 North, Range 39 East, Sections 14-17, 20 & 24 Township 10 North, Range 40 East, Sections 19 & 30

436

Microsoft Word - CX-Covington_Substation_WEB.doc  

Broader source: Energy.gov (indexed) [DOE]

Harvey Schowe Harvey Schowe Project Manager - TESF-CSB-2 Proposed Action: Installation of new water system (potable and fire suppression) to entire Covington Complex PP&A Project No.: PP&A-1601 Budget Information: Work Order # 00257082 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B4.6 Additions/modifications to electric power transmission facilities within previously developed area. Location: Covington Substation in King County, Washington Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: In order to provide adequate potable and fire-suppression water to buildings within the Covington Complex, BPA proposes to install approximately 1,500 feet of new potable water line and fire main line. One trench will be dug at a depth of 4-5 feet to carry both new pipes for the

437

Environmental noise of a nuclear power plant and its substations  

Science Journals Connector (OSTI)

In order to fulfill government requirements for construction of a nuclear power plant an environmental noiseimpact as?assessment has been conducted. Ambient noise was measured continuously for 24 hour periods at the plant and substation sites and in the vicinity. Week long surveys were performed in each of the four seasons. A statistical interpretation of construction noise accounts for variability of construction equipment usage its location and range of sound pressure levels. Histograms of construction noise and measured ambient noise are added to obtain the statistical representation of the predicted construction ambient noise. Operational noise of the plant is similarly predicted. The predicted noise contours of both operation and construction noise are formulated on the topographic maps. Meteorologic and topographic effects on the noise data are discussed.

E. E. Dennison; R. E. Maier; J. W. McGaughey; S. P. Ying

1976-01-01T23:59:59.000Z

438

Microsoft Word - Cascade Networks Allston Substation LURR CX.doc  

Broader source: Energy.gov (indexed) [DOE]

15, 2011 15, 2011 REPLY TO ATTN OF: KEC-4 SUBJECT: Environmental Clearence Memorandum Harold Grappe - TELP-TPP-3 Proposed Action: Cascade Networks, Inc. LURR at Allston Substation Budget Information: Work Order # 00275035 Task 03 Categorical Exclusions Applied (from Subpart D, 10 C.F.R. Part 1021: B1.7 "Acquisition, installation, operation, and removal of communication systems, data processing equipment, and similar electronic equipment." B4.7 "Adding fiber optic cable to transmission structures..." Location: Section 10, Township 7 North, Range 3 West of the Delena Quadrangle located in Columbia County, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to grant Cascade Networks, Inc. permission to

439

Optimal location and sizing of HV/MV substations in uncertainty load environment using genetic algorithm  

Science Journals Connector (OSTI)

In this paper a novel approach for optimal location, sizing and determining the service areas of HV/MV substations in a long-range planning period using pseudodynamic methodology is presented. Costs of equipment, areas, cables in MV side and power loss are considered in cost function. Uncertainty in loads is modeled using LR fuzzy numbers in load points. For optimization procedure, genetic algorithm with a new coding is used. Load points splitting in each area between substations and infeasibility solutions are considered in search procedure. Based on this, a software was developed and integrated into an optimization tool for substation allocation. The software was applied in many cases with satisfactory results.

M.R Haghifam; M Shahabi

2002-01-01T23:59:59.000Z

440

Seismic fragility analysis of equipment and structures in a Memphis Electric substation. Technical report  

SciTech Connect (OSTI)

This report presents a seismic fragility analysis of equipment and structures in an electric substation in Memphis, Tennessee. These include the pothead structure, 115 kv switch structure, 97 kv lightning arresters, control house, capacitor banks, 115/12 kv transformers, 12 kv regulators, 115 kv oil circuit breakers, and 12 kv oil circuit breakers. The results from this fragility analysis provide the expected performance of equipment and structures in a substation. They can also be used to evaluate the seismic performance of the entire electric substation and to perform a system reliability analysis of the electric transmission system.

Huo, J.R.; Hwang, H.H.M.

1995-08-10T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Categorical Exclusion (CX) Determination Proposed Action: Expansion of O'Fallon Creek Substation Yard  

Broader source: Energy.gov (indexed) [DOE]

Expansion of O'Fallon Creek Substation Yard Expansion of O'Fallon Creek Substation Yard Description of Proposed Action: The Western Area Power Administration (Western) is proposing to expand the current yard to accommodate an additional bay for a dedicated electrical feed to a future oil pumping station that will be part of the Keystone XL project. Number and Title of Categorical Exclusions Being Applied: 10 CFR 10210410 Subpmi D, Appendix B, B4.11: Construction of electric power substations ... or modification of existing substations and support facilities. Regulatory Requirements for CX Determination: The DOE Guidelines for Compliance with the Regulatory Requirements for the National Environmental Policy Act at 10 CFR 1021AI0(b), require the following determinations be made in order for a proposed action to be categorically

442

Microsoft Word - CX-SnoKingSubstationExpansionFY12_WEB.doc  

Broader source: Energy.gov (indexed) [DOE]

Michael Marleau Michael Marleau Project Manager - TEP-TPP-1 Proposed Action: Sno-King Substation Expansion Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): Appendix B4.11 Electric power substations and interconnection facilities Location: Bothell, Snohomish County, WA Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA is proposing to expand its Sno-King Substation's fenced electrical yard by approximately 0.2 acres to accommodate new equipment. The substation expansion is necessary to make room for the addition of a back-up 500/230-kV power transformer, which BPA can energize in the event of a primary transformer failure. The additional transformer will increase the safety and reliability of the system.

443

A methodology for performance and compatibility evaluation of an all-digital substation protection system  

E-Print Network [OSTI]

whether to operate associated circuit breaker(s). Existing protection systems within a substation are based on a hardwired interface between instrument transformers and protective relays. Recent development of electronic instrument transformers...

Portillo Urdaneta, Levi

2007-04-25T23:59:59.000Z

444

Synchrophasor Measurement Using Substation Intelligent Electronic Devices: Algorithms and Test Methodology  

E-Print Network [OSTI]

This dissertation studies the performance of synchrophasor measurement obtained using substation Intelligent Electronic Devices (IEDs) and proposes new algorithms and test methodology to improve and verify their performance when used in power system...

Ren, Jinfeng

2012-02-14T23:59:59.000Z

445

An Integrative Approach to Reliability Analysis of an IEC 61850 Digital Substation  

E-Print Network [OSTI]

In recent years, reliability evaluation of substation automation systems has received a significant attention from the research community. With the advent of the concept of smart grid, there is a growing trend to integrate more computation...

Zhang, Yan 1988-

2012-11-28T23:59:59.000Z

446

Study on integrated automation system of traction substation for express railway lines  

Science Journals Connector (OSTI)

The structure and function of integrated automation system of traction substation for express electric railway lines developed by our university are discussed in this paper. The paper mainly describes the function installation of monitoring and communication ...

Gao Shibin; Chen Xiaochuan; Wang Qian; Wang Ren; Chen Weirong; Xiong Liebin

2002-11-01T23:59:59.000Z

447

EPON’s Research on Transmission of Sampling Value in Process Level of Digital Substation  

Science Journals Connector (OSTI)

Non-conventional instrument transformers and optical fiber communication are utilized in secondary system of digital substation. Sampling value signals are transmitted to Merging ... Finally, the deployment of EP...

Qiu Ming-yi; Xu Xi-dong

2013-01-01T23:59:59.000Z

448

Modelling and analysis of protection and control applications in smart substation  

Science Journals Connector (OSTI)

The real-time transaction processing was a key and challenging technology to protect systems from various failures in smart substation. This paper introduces the time critical communication between the protection and control devices and the primary apparatuses in three-level communication network architecture based on IEC61850, and analyses the process of information exchange and delay requirement of Protection and Control (P&C) applications between level and level, bay and bay, station and station in smart substation. The generic model of the P&C applications was modelling by latency requirement on OPNET, then the simulation and discussion on using those models to construct IEC61850 network validated the real-time of the application model. In the meantime, the delay performance of the P&C application is analysed in scenarios multiple services sharing substation network, which is an attempt to discuss the possibility of establishing a smart substation network simulation platform on OPNET.

Xingyong Yu; Jiang Yu; Jun Chang

2014-01-01T23:59:59.000Z

449

Near field coupling to shielded cable due to switching operation in substation  

Science Journals Connector (OSTI)

It is vital to study the electromagnetic coupling to shielded cable for improving electromagnetic antiinterference ability of secondary equipment in a substation. As a hybrid of method of moment ... shielded cabl...

Lei Qi; Xiang Cui

2008-09-01T23:59:59.000Z

450

A simple approach to improve lightning performance of an uprated substation  

SciTech Connect (OSTI)

This paper presents a simple method to minimize lightning surges entering an uprated or compact substation. A severe lightning stress is caused by a backflashover in close proximity to the substation. Feasibility of uprating is based on the surge arrester technology available at present. However, some aspects of line design offer opportunities in reducing frequency and severity of lightning surges imposed on the substation. The tower surge response adds an inductive overshoot only during the front of the stroke which reduces considerably during the tail. If backflashover does not occur before reflections from adjacent towers arrive, it is unlikely to occur at all. Use of guys and underbuilt ground wires in the limiting distance will produce reflections with larger magnitude and reduce the effective surge impedance of the tower. This would not only reduce backflashover frequency but will also minimize crest and duration of surges entering the substation.

Harrington, R.J.; Mueen, M. [George Washington Univ., Washington, DC (United States). Dept. of Electrical Engineering and Computer Science] [George Washington Univ., Washington, DC (United States). Dept. of Electrical Engineering and Computer Science

1996-07-01T23:59:59.000Z

451

An Adaptive Fast Multipole Higher Order Boundary Element Method for Power Frequency Electric Field of Substation  

Science Journals Connector (OSTI)

An adaptive fast multipole higher order boundary element method combining fast multipole (FM) with a higher order boundary element method is studied to solve the power frequency electric field (PFEF) of substations. In this new technique, the iterative equation solver GMRES is used in the FM, where matrix-vector multiplications are calculated using fast multipole expansions. The coefficients in the preconditioner for GMRES are stored and are used repeatedly in the direct evaluations of the near-field contributions. Then a 500kV outdoor substation is modeled and the PFEF of the substation is analyzed by the novel algorithm and other conventional methods. The results show that, in computational cost and the storages capability aspects, the algorithm proposed in this study has obvious advantages. It is suitable for the calculation of the large-scale PFEF in complex substations and the design of electromagnetic compatibility.

Zhang Zhan-Long; Deng Jun; Xiao Dong-Ping; He Wei; Tang Ju

2010-01-01T23:59:59.000Z

452

THURSDAY: Deputy Secretary of Energy to Visit Western Area Power Administration Transmission Substation  

Broader source: Energy.gov [DOE]

Deputy Secretary of Energy Elizabeth Sherwood-Randall will visit the Western Area Power Administration for a ceremony at the Electrical District No. 5 Substation to view progress on the Electrical District 5-to-Palo Verde transmission project.

453

Annotated Bibliography of UHV AC Substation Equipment, 1968-1985.  

SciTech Connect (OSTI)

This bibliography is divided into sections dealing with insulation coordination, switchgear, shunt reactors, surge arresters, power transformers, current and voltage measurement equipment, station design and operating experience, and testing facilities. (DLC)

Lava, Val

1985-08-01T23:59:59.000Z

454

A probabilistic method for establishing the transformer capacity reserve criteria for HV/MV substations  

SciTech Connect (OSTI)

This paper provides an extension of methods for computing reliability indices for substations which takes into account the permissible overload of the power transformer, the daily load cycle and emergency loading. Based on the reliability indices derived in this paper it is possible to determine a reliability criterion for the rating of the substation, the number of transformers and the reserve factor required, which have traditionally been based on conservative deterministic criteria.

Elmakis, D.; Braunstein, A.; Naot, Y.

1986-11-01T23:59:59.000Z

455

Report of Progress with Citrus Fruits at the Beeville Sub-Station, Bee County.  

E-Print Network [OSTI]

65-109-5m TEXAS AGRICULTURAL EXPERIMENT STATIONS. -T- I . ! '? . ........ ?' ? r ; 'V ? J 'V ? ? ? BULLETIN NO. 118. February, 1 9 0 9 . REPORT Of PROGRESS WITH CITRUS FRUITS AT THE BEEVILLE SUB-STATION, BEE COUNTY S. A. WASCHKA................. ................................Stenographer. A. S. F IB5 mmmmmmmmmmmmmmmmmmmmmmmmmmmmm mmmmmmmmmmmmmmm STATE SUBSTATIONS. H. H. R IBBC8 -1X8 mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmDirector. W. S. R X1uoMCPP0 Superintendent...

Waschka, S. A.

1909-01-01T23:59:59.000Z

456

Cotton Variety Experiments, 1912-1920, Substation No. 7, Spur, Texas.  

E-Print Network [OSTI]

TEXAS A6RICULTURAL EXPERIMENT STATION AGRICULTURAL AND MECHANICAL COLLEGE OF TEXAS W. B. BIZZELL, President BULLETIN NO. 288 FEBRUARY, 1922 DIVISION OF COTTON BREEDING COTTON VARIETY EXPERIMENTS, 1912-1920, SUBSTATION NO. 7, SPUR, TEXAS B..., Sorl Survegor H. V. GEIB, B. S., Soil Surveyor FEED CONTROL SERVICE B YOUNGBLOOD Ph D Director F.' D. FULLER, M. s.; ~xicf Inspecfor S. D. PEARCE, Inspector J. H. ROGERS, Inspecfor W. H. WOOD, Inspector SUBSTATIONS l%. 'l. Beeville Bee County...

Freeman, George Fouche; Dickson, R. E

1922-01-01T23:59:59.000Z

457

Progress Report of Substation No. 3, Angleton, Texas, 1909-1914.  

E-Print Network [OSTI]

TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 197 NOVEMBER, 1916 PROGRESS REPORT OF SUBSTATION NO. 3, ANGLETON, TEXAS POSTOFFICE : COLLEGE STATION, BRAZOS COUNTY, TEXAS. +sB AUSTIN, TEXAS : VON BOECKMANN-JONES CO., PRINTERS, 1916.... [Blank Page in Original Bulletin] TEXAS A(;RICULTURAl, EXPERIMENT STATION BULLETIN NO. 197 NOVEMBER, 1916 PROGRESS REPORT OF SUBSTATION NO. 3, ANGLETON, TEXAS N. E. WINTERS, B. S., SUPERINTENDENT POSTOFFICE : COLLEGE STATION, BRAZOS COUNTY, TEXAS...

Winters, N. E. (Nathaniel Elmer)

1916-01-01T23:59:59.000Z

458

Progress Report, Texas Substation No. 6, Denton, Texas, 1909-14.  

E-Print Network [OSTI]

TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 199 DECEMBER, 1916 PROGRESS REPORT, TEXAS SUBSTATION NO. 6, DENTON, TEXAS POSTOFFICE : COLLEGE STATION, BRAZOS COUNTY, TEXAS. - AUSTIN, TEXAS : VON BOECKMANN-JONES CO., PRINTERS, 1916.... [Blank Page in Original Bulletin] TEXAS AGRICULTURAL EXPERIMENT STATION BULLETIN NO. 199 DECEMBER, 1916 PROGRESS REPORT, TEXAS SUBSTATION NO. 6, DENTON, TEXAS V. L. CORY, B. S. . SUPERINTENDENT , . POSTOFFICE : COLLEGE STATION, BRAZOS COUNTY...

Cory, V. L. (Vivian L.)

1916-01-01T23:59:59.000Z

459

Proceedings of the Seventh Intemational Workshop on  

E-Print Network [OSTI]

of a sequential real time simulator for High Voltage (HV) electrical substations, currently in use at ENEL;Performance prediction of a reconfigurable high voltage substation simulator: a case study using SWN C of a high voltage substation simulator with real time constraints, running on a multiprocessor ar

Anglano, Cosimo

460

Electrical substation service-area estimation using Cellular Automata: An initial report  

SciTech Connect (OSTI)

The service areas for electric power substations can be estimated using a Cellular Automata (CA) model. The CA model is a discrete, iterative process whereby substations acquire service area by claiming neighboring cells. The service area expands from a substation until a neighboring substation service area is met or the substation`s total capacity or other constraints are reached. The CA-model output is dependent on the rule set that defines cell interactions. The rule set is based on a hierarchy of quantitative metrics that represent real-world factors such as land use and population density. Together, the metrics determine the rate of cell acquisition and the upper bound for service area size. Assessing the CA-model accuracy requires comparisons to actual service areas. These actual service areas can be extracted from distribution maps. Quantitative assessment of the CA-model accuracy can be accomplished by a number of methods. Some are as simple as finding the percentage of cells predicted correctly, while others assess a penalty based on the distance from an incorrectly predicted cell to its correct service area. This is an initial report of a work in progress.

Fenwick, J.W.; Dowell, L.J.

1998-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Fault diagnosis of electric railway traction substation with model-based relation guiding algorithm  

Science Journals Connector (OSTI)

Abstract Most diagnosis systems used in electric railway traction substation are expert systems based on experience, which cannot diagnose faults beyond experience and are very difficult for transplantation and maintenance. In this paper, the model-based diagnosis (MBD) with integration reasoning is firstly used for fault diagnosis of electric railway traction substation. Aiming at the structural characteristics and actual demands of traction substation, we propose a detailed application plan. Rules for element and system models are established. In addition, we propose a relation guiding algorithm (RGA) for searching candidates of minimal conflict set, in which the hidden messages of analytical redundancy relations can be made full use of and the searching space is reduced further. Taking the autotransformer (AT) traction substation in Hefei–Nanjing Passenger Link of China Railway as an example, we construct models for different device objects, and give the descriptions of system model in traction substation. Based on a sequence of fault observations, the fault diagnosis is tested with the proposed plan. The diagnosis result shows that the application plan with MBD and integration reasoning is feasible and effective for traction substation.

Zhigang Liu; Zhiwei Han

2014-01-01T23:59:59.000Z

462

Peculiarities of the current-voltage characteristics of a Josephson medium in a YBCO high-temperature superconductor  

Science Journals Connector (OSTI)

The influence of a weak magnetic field (H high-temperature superconductor (HTSC) near the superconducting transitio...

M. A. Vasyutin

2013-12-01T23:59:59.000Z

463

RECIPIENT:Princeton Power Systems STATE: NJ PROJECT Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage  

Broader source: Energy.gov (indexed) [DOE]

Princeton Power Systems Princeton Power Systems STATE: NJ PROJECT Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage TITLE: Funding Opportunity Announcement Number Procurement Instrument Number NEPA Control Number cm Number DE-FOA-0000293 DE-EE0003640 GFO-000364~001 GOO Based on my review of the information concerning the proposed action, as NEPA Compliance Officer (authorized under DOE Order 451.1A), I have made the foUowing determination: CX, EA, EIS APPENDIX AND NUMBER: Description: A9 Information gathering (including, but not limited to, ~terature surveys, inventories, audits), data analysis (including computer modeling), document preparation (such as conceptual design or feasibility studies, analytical energy supply

464

Structure Design and Test Research on the Electrical Properties of High Voltage Instrumentation Cables for the Fusion Reactor  

Science Journals Connector (OSTI)

The HV instrumentation cable is an important route for the signals transmission from the superconducting magnets to the control system, it should be long term operated at around 4.2 K and withstand the high vo...

Qingsheng Gao; Xiongyi Huang; Yuntao Song; Weibin Xi…

2014-08-01T23:59:59.000Z

465

Influence of high voltage atmospheric cold plasma process parameters and role of relative humidity on inactivation of Bacillus atrophaeus spores inside a sealed package  

Science Journals Connector (OSTI)

SummaryBackground Non-thermal plasma has received much attention for elimination of microbial contamination from a range of surfaces. Aim This study aimed to determine the effect of a range of dielectric barrier discharge high voltage atmospheric cold plasma (HVACP) parameters for inactivation of Bacillus atrophaeus spores inside a sealed package. Methods A sterile polystyrene Petri dish containing B. atrophaeus spore strip (spore population 2.3 × 106/strip i.e. 6.36 log10/strip) was placed in a sealed polypropylene container and was subjected to HVACP treatment. The HVACP discharge was generated between two aluminium plate electrodes using a high voltage of 70 kVRMS. The effects of process parameters, including treatment time, mode of exposure (direct/indirect), and working gas types, were evaluated. The influence of relative humidity on HVACP inactivation efficacy was also assessed. The inactivation efficacy was evaluated using colony counts. Optical absorption spectroscopy (OAS) was used to assess gas composition following HVACP exposure. Findings A strong effect of process parameters on inactivation was observed. Direct plasma exposure for 60 s resulted in ?6 log10 cycle reduction of spores in all gas types tested. However, indirect exposure for 60 s resulted in either 2.1 or 6.3 log10 cycle reduction of spores depending on gas types used for HVACP generation. The relative humidity (RH) was a critical factor in bacterial spore inactivation by HVACP, where a major role of plasma-generated species other than ozone was noted. Direct and indirect HVACP exposure for 60 s at 70% RH recorded 6.3 and 5.7 log10 cycle reduction of spores, respectively. Conclusion In summary, a strong influence of process parameters on spore inactivation was noted. Rapid in-package HVACP inactivation of bacterial spores within 30–60 s demonstrates the promising potential application for reduction of spores on medical devices and heat-sensitive materials.

S. Patil; T. Moiseev; N.N. Misra; P.J. Cullen; J.P. Mosnier; K.M. Keener; P. Bourke

2014-01-01T23:59:59.000Z

466

Development of an embedded system actuator node for intergration into an IEC 61850 based substation automation application.  

E-Print Network [OSTI]

??The introduction of the IEC 61850 standard in substations for communication networks and systems by the International Electrotechnical Commission (IEC) in 2003 provided the possibility… (more)

Retonda-Modiya, John-Charly

2012-01-01T23:59:59.000Z

467

The influence of tropical operating conditions on the AC and impulse breakdown strength in gas insulated substation (GIS):.  

E-Print Network [OSTI]

??The ambient conditions could influence the breakdown strength of gas insulated substation. It is important to check if this influence will put the GIS into… (more)

Sihombing, H.

2009-01-01T23:59:59.000Z

468

Automatic voltage imbalance detector  

DOE Patents [OSTI]

A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

Bobbett, Ronald E. (Los Alamos, NM); McCormick, J. Byron (Los Alamos, NM); Kerwin, William J. (Tucson, AZ)

1984-01-01T23:59:59.000Z

469

Rural community noise caused by 345/138 kV substation transformer  

Science Journals Connector (OSTI)

Residents 360 m (1200 ft) from a large (6 × 8 × 4.5 m high) 345/138 kV transformer installed in a new power substation in a rural setting complained of its noise emission especially at night. Octave band and 24?h A?weighted noise measurements were made. The 120?Hz sound level was found to be 90 to 105 dB at the transformer surface. Transformer noise emission did not vary significantly with transformer loading or time of day. The distant (360 m) noise level was from 40 to 47 dBA (N?30 to N?45) depending on intervening terrain and time of day. In calm summer air the annoying sound was found to be in the 125?Hz band at the residence beyond a vegitated rise and 250 to 500 Hz for a residence with line?of?sight contact over a shallow depression. The line?of?sight resident's complaint that the noise was greatest at night was corroborated by the 24?h measurement. That noise level was found to be typically 38 dBA from 11 a.m. to 7 p.m. and 45 dBA from 9 p.m. to 6 a.m. It is postulated that the depression accumulated cool air at night thus refracting the sound onto that site. Recommendations for a noise barrier wall was made to the power company operator.

Angelo J. Campanella

1981-01-01T23:59:59.000Z

470

Electricity Distribution  

Science Journals Connector (OSTI)

High voltage (HV) distribution grids have nominal voltages of up ... the grid that connects distribution to the transmission substations and also supplies large industrial customers requiri...

Tomás Gómez

2013-01-01T23:59:59.000Z

471

Ignition distributor voltage generator  

SciTech Connect (OSTI)

This patent describes a voltage pulse generator and ignition distributor comprising, a base, a shaft rotatably supported by the base, a distributor cap supported by the base having a center electrode and circumferentially spaced outer electrodes. The pulse generator and ignition distribution also include a first rotor driven by the shaft formed of electrical insulating material having electrically conductive means connected to the center terminal and a portion that rotates past the outer electrodes. The portion of the electrically conductive means that rotates past the outer electrodes is spaced from the outer electrodes to form a gap therebetween. A voltage pulse generator comprises a second rotor driven by the shaft, at least one permanent magnet and an annular pickup coil supported by the base. The pickup coil has inner turns and outer turns, the beginning turn of the inner turns connected to a first lead and the last turn of the outer turns connected to a second lead, the outer turns enclosing the inner turns. The pickup coil also has a circuit connected directly between the second lead and ground which is operative to provide a direct conductive path to ground for high frequency energy capacitively coupled to the outer turns from the gap discharge between the electrically conductive means of the first rotor and an outer electrode, the outer turns forming a grounded shield for the inner turns.

Boyer, J.A.

1986-11-04T23:59:59.000Z

472

EIS-0400: Granby Pumping Plant Switchyard-Windy Gap Substation Transmission  

Broader source: Energy.gov (indexed) [DOE]

EIS-0400: Granby Pumping Plant Switchyard-Windy Gap Substation EIS-0400: Granby Pumping Plant Switchyard-Windy Gap Substation Transmission Line Rebuild Project, Grand County, CO EIS-0400: Granby Pumping Plant Switchyard-Windy Gap Substation Transmission Line Rebuild Project, Grand County, CO Summary Western Area Power Administration prepared an EIS, with the U.S. Forest Service, Bureau of Land Management, and Grand County (Colorado) as cooperating agencies, to evaluate the potential environmental impacts of rebuilding a 12-mile, 69-kV electric transmission line in Grand County. The proposed project would rebuild the single-circuit line as a double-circuit transmission line and add a second power transformer. Western identified potentially significant impacts while preparing an EA for this proposal (DOE/EA-1520) and prepared an EIS instead of completing

473

EIS-0400: Granby Pumping Plant Switchyard-Windy Gap Substation Transmission  

Broader source: Energy.gov (indexed) [DOE]

00: Granby Pumping Plant Switchyard-Windy Gap Substation 00: Granby Pumping Plant Switchyard-Windy Gap Substation Transmission Line Rebuild Project, Grand County, CO EIS-0400: Granby Pumping Plant Switchyard-Windy Gap Substation Transmission Line Rebuild Project, Grand County, CO Summary Western Area Power Administration prepared an EIS, with the U.S. Forest Service, Bureau of Land Management, and Grand County (Colorado) as cooperating agencies, to evaluate the potential environmental impacts of rebuilding a 12-mile, 69-kV electric transmission line in Grand County. The proposed project would rebuild the single-circuit line as a double-circuit transmission line and add a second power transformer. Western identified potentially significant impacts while preparing an EA for this proposal (DOE/EA-1520) and prepared an EIS instead of completing

474

Microsoft Word - CX-Marion and Sand Springs Substation Towers Revised.doc  

Broader source: Energy.gov (indexed) [DOE]

KEC-4 KEC-4 SUBJECT: Environmental Clearance Memorandum Dave Tripp Project Manager - TEP-CSB-1 Proposed Action: Marion and Sand Springs Substations Radio Tower Projects Budget Information: Work Orders 00243411 and 00243190; Task 3 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.19 Siting, construction, and operation of microwave and radio communication towers and associated facilities... Location: Marion and Deschutes counties, Oregon Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to install new radio towers at the Marion Substation and Sand Springs Substation communication sites in Oregon. BPA must vacate radio frequencies in the 1710-1755MHz band to comply with a Federal law mandating reallocation of

475

Control of offshore marine substation for grid-connection of a wave power farm  

Science Journals Connector (OSTI)

Abstract To grid-connect an offshore wave power farm, an intermediate marine substation is suggested. As a part of the Uppsala University wave power project, a marine substation has been designed, assembled and deployed at sea. The substation is capable of connecting up to seven wave energy converters (WECs), and to transfer the power to the onshore 1 kV-grid. In this article, the control procedure for grid connection of the \\{WECs\\} is described step-by-step, and the practical implementations are presented. The system is designed with autonomous control and will connect or disconnect the WECs, depending on the sea state. Fault handling is taken into account, and grid power quality such as harmonic distortion and flicker are considered in the design. Experimental results are presented to verify the system functionalities.

Rickard Ekström; Mats Leijon

2014-01-01T23:59:59.000Z

476

Design of active loops for magnetic field mitigation in MV/LV substation surroundings  

Science Journals Connector (OSTI)

Abstract This paper deals with the application and optimization of active loops for the mitigation of the magnetic field generated by complex sources, especially MV/LV substations. Various active-loop configurations are proposed, which are analyzed in several regions located close to a particular MV/LV substation, and the optimum geometry and location of the loops are obtained together with the optimum current (magnitude and phase) to be injected into the loops. All this is performed by means of a genetic algorithm in order to reduce the average magnetic field inside the target volume (inspection volume) to the minimum. The performance of the proposed active loops is compared with that obtained via other well-known mitigation technique, such as conductive/ferromagnetic passive shields. The main results are analyzed, and the differences, in terms of performance, between the two shielding techniques, and their proper application to MV/LV substations, are highlighted.

Juan Carlos del-Pino-López; Luca Giaccone; Aldo Canova; Pedro Cruz-Romero

2015-01-01T23:59:59.000Z

477

Power Evaluation of Jakarta DC Railway Substation to Meet 1.2 Million Passengers Per Day  

Science Journals Connector (OSTI)

Abstract Jakarta is a metropolitan city that continues to strive to develop the capacity of its mass transport as other large cities in the world, primarily the development of the rail-based transportation. Indonesia Railway Company (PT Kereta Api (Persero)) had forecasted that there will be 1.2 million passengers per day on Jakarta in 2019. To meet these targets, it is necessary to adequate the infrastructure planning, especially the capacity of the DC substations which supply the electric power to the trains. This paper will demonstrate the strategy used to determine the point of placement of new DC substation and/or existing DC substation upgrades throughout the Jakarta area from 2013 to 2019. The current railway timetable and the future pattern of railway operation plan are used to predict the possibilities of peak load spots along the track.

Yanuarsyah Haroen; Tri Desmana Rachmildha; M. Ikhsan; M. Ivan Fikriadi

2013-01-01T23:59:59.000Z

478

Microsoft Word - Chenoweth-Substation-3G-RS-CX.doc  

Broader source: Energy.gov (indexed) [DOE]

4, 2010 4, 2010 REPLY TO ATTN OF: KEC-4 SUBJECT: Environmental Clearance Memorandum Creig Millen Project Manager - TEC-CSB-1 Proposed Action: Chenoweth Substation 3G Radio Station Project Budget Information: Work Order 00197213, Task 03 Categorical Exclusion Applied (from Subpart D, 10 C.F.R. Part 1021): B1.19 Siting, construction, and operation of microwave and radio communication towers and associated facilities... Location: Wasco County, Oregon (T2N, R13E, Sections 21and 28) Proposed by: Bonneville Power Administration (BPA) Description of the Proposed Action: BPA proposes to construct a 120-foot radio tower and antenna system at BPA's Chenoweth Substation in Wasco County, Oregon. The new tower will require a 20 x 20 foot expansion of the existing substation yard and will replace an existing 50-foot monopole

479

Dielectric-wall linear accelerator with a high voltage fast rise time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators  

DOE Patents [OSTI]

A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface. 12 figs.

Caporaso, G.J.; Sampayan, S.E.; Kirbie, H.C.

1998-10-13T23:59:59.000Z

480

A 4000-A HVDC (high-voltage direct-current) circuit breaker with fast fault-clearing capability: Final report  

SciTech Connect (OSTI)

This project is a follow-up of the first development of a 500 kV HVDC airblast circuit breaker (EPRI project 1507-3). The objective was to increase the current interrupting capability from 2200 A to 4000 A and shorten its fault clearing time. A high current 500 kV HVDC circuit breaker has been built using the passive commutation circuit. The breaker is modular in construction and can be designed for a wide variety of system conditions. More than 400 current interruptions were carried out successfully. Tests have shown that this circuit breaker is capable of interrupting more than 4000 A dc. Practical breakers with current interrupting capability of even 5500 A dc could be built. The circuit breaker operation and the fault-clearing process can be materially speeded up if the trip signal is given as soon as the fault is detected and without waiting for the current levels to come down in response to converter control action. The new dc breakers are shown to be capable of withstanding these transient arc currents of 8000 A without affecting its ability to interrupt the direct current that follows the transient. This transient current withstand capability is greater than is likely to occur during dc faults. The fault clearing time of this HVDC circuit breaker is comparable to the fault clearing time of conventional ac breakers for ac faults. The developed HVDC circuit breaker is now commercially available and can be supplied for use in HVDC systems. Its use in such systems is expected to provide flexibility in system design and contribute to system stability. 38 refs., 52 figs., 9 tabs.

Not Available

1988-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage substation" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Study on Tubular Busbar Corona Design Optimization of ±660kV HVDC Converter Substation in Qingdao  

Science Journals Connector (OSTI)

The HVDC busbar corona characteristic is the main factor taken into account for choosing busbar of HVDC converter substation. By establishing the calculation models of electric field strength along the busbar surface, ground total electric field strength ... Keywords: ±660 kV HVDC, converter substation, corona characteristics, electromagnetic, tubular busbar optimization

Xu Mingming; Li Kejun; Tan Zhenyu; Niu Lin

2010-06-01T23:59:59.000Z

482

Substations reliability-centered maintenance and predictive maintenance - a strategic partnership  

SciTech Connect (OSTI)

A maintenance optimization study for substation components can be most effective when Reliability Centered Maintenance (RCM) Analysis is combined with a Predictive Maintenance (PDM) Assessment. If the two processes are performed concurrently, the benefit-to-cost ratios for each is increased. Also, the cost of implementing RCM recommendations for condition monitoring can be minimized, while maximizing their impact at the same time. This paper presents the essential elements of both the RCM and PDM processes, and describes how they work together in a substation environment as a comprehensive maintenance assessment tool. Descriptions of recent experiences are also included.

Colsher, R.J. [Electric Power Research Institute, Eddystone, PA (United States); Abbott, P.D.; Matusheski, R.L. [EPRI & MD Center, Eddystone, PA (United States); Smith, S.B. [ERIN Engineering & Research, Walnut Creek, CA (United States)

1996-08-01T23:59:59.000Z

483

You will be hired in our Local Business Unit Substations (Power Systems Division) and, in the role of Service Sales Specialist, you will drive the  

E-Print Network [OSTI]

You will be hired in our Local Business Unit Substations (Power Systems Division) and, in the role and profitability targets for Substations Systems Your contact: Veronica Meloni, Talent Acquisition Department professionals. Requirements You have at least 2 or 3 years experience in the Substations segment and you have

Segatti, Antonio

484

Structural Assignments and Dynamics of the A Substates of MbCO: Spectrally Resolved Vibrational Echo Experiments and Molecular Dynamics Simulations  

E-Print Network [OSTI]

Structural Assignments and Dynamics of the A Substates of MbCO: Spectrally Resolved Vibrational of the A1 and A3 spectroscopic substates in the IR spectrum of the carbon monoxide (CO) stretch of carbonmonoxymyoglobin (MbCO). The measured dephasing dynamics of these substates is compared to the dephasing dynamics

Fayer, Michael D.

485

Classification of Voltage Sags Based on MPCA Models  

Science Journals Connector (OSTI)

In this paper, we introduce a new framework for classification of short duration voltage reductions in the area of Power Quality Monitoring using Multiway Principal Component Analysis (MPCA). Firstly, we recast the sags occurred in High Voltage (HV) ...

Abbas Khosravi; Joaquim Melendez; Joan Colomer

2007-06-01T23:59:59.000Z

486

A hybrid intelligent system for alarm processing in power distribution substations  

Science Journals Connector (OSTI)

This application paper presents an intelligent system for alarm processing and fault location in power substations. A hybrid model is constructed using rule-based systems and an artificial neural network. Incoming alarms are initially handled by an input ... Keywords: Expert systems, fault location, neural networks

J. C. Stacchini de Souza; M. B. Do Coutto Filho; R. S. Freund

2010-04-01T23:59:59.000Z

487

Level 1 Accident Report of the March 1, 2010 Bobcat Fatality at BPA's White Bluffs Substation  

Broader source: Energy.gov [DOE]

On March 2, 2010 at the request of the Bonneville Power Administration (BPA) Chief Safety Officer, a Level I Accident Investigation was convened to investigate an accident in which a supplemental labor contractor was fatally injured in a Bobcat/backhoe accident at the White Bluffs Substation near Richland, Washington on March 1, 2010.

488

Puget Sound Area Electric Reliability Plan : Supplemental Environmental Analysis, Schultz Substation.  

SciTech Connect (OSTI)

This document describes the purpose, function, and the environmental consequences of the proposed Schultz substation near Ellensburg, Washington. The affected environment is described in detail, including aerial survey photographs. The impacts on vegetation, fish and wildlife, soils, and water resources are described. (GHH)

United States. Bonneville Power Administration.

1992-04-01T23:59:59.000Z

489

The Design of Substation Avalanche Test System Based on B Code  

Science Journals Connector (OSTI)

This paper describes a substation avalanche test system which is based on B code. The system supports simultaneous operation of multiple remote signaling and can ensure the synchronization and accuracy of time's movement. Using platform of ARM9 hardware ... Keywords: B code, time synchronization system, avalanche tested, embedded operating system

Guo Ying, Liu Nan

2013-11-01T23:59:59.000Z

490

Generalized Bouc-Wen model for highly asymmetric hysteresis  

E-Print Network [OSTI]

interconnected electrical substation equipment. ” PEER Rep.interconnected electrical substation equipment subjected toconnected electrical substation equipment. ” Earthquake Eng.

Song, J; Kiureghian, A D

2006-01-01T23:59:59.000Z

491

Modulated voltage metastable ionization detector  

SciTech Connect (OSTI)

Metastable ionization detectors used for chromatographic analysis usually employa fixed high voltage for the ionization potential. For this reason, the operating range is limited to about three orders of magnitude. By use of the technique disclosed in the instant invention, operating ranges of about nine orders of magnitude are obtained. The output current from a metastable ionization detector (MID) is applied to a modulation voltage circuit. An adjustment is made to balance out the background current, and an output current, above background, is applied to an input of a strip chart recorder. For low level concentrations, i.e., low detected output current, the ionization potential will be at a maximum and the metastable ionization detector will operate at its most sensitive level. When the detected current from the metastable ionization detector increases above a predetermined threshold level, a voltage control circuit is activated which turns on a high voltage transistor which acts to reduce the ionization potential. The ionization potential applied to the metastable ionization detector is then varied so as to maintain the detected signal level constant. The variation in ionization potential is now related to the concentration fo the constituent and a representative amplitude is applied to another input of said strip chart recorder.

Carle, G. C.; Humphry, D. E.; Kojiro, D. R.

1985-08-27T23:59:59.000Z

492

Vehicle Technologies Office Merit Review 2014: High Energy Density Li-ion Cells for EV’s Based on Novel, High Voltage Cathode Material Systems  

Broader source: Energy.gov [DOE]

Presentation given by Farasis Energy, Inc. at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about high energy density Li...

493

Voltage flicker prediction for two simultaneously operated ac arc furnaces  

SciTech Connect (OSTI)

An EMTP-based arc furnace model was developed for evaluation of flicker concerns associated with supplying a large integrated steel mill as they go from one to two furnace operation and as system changes are implemented that will affect the short circuit capacity at the 230 kV power supply substation. The model includes a dynamic arc representation which is designed to be characteristic of the initial portions of the melt cycle when the arc characteristics are the most variable (worst flicker conditions). The flicker calculations are verified using previous measurements with one furnace operation. Flicker simulations were then performed to evaluate a variety of different possible system strengths with both one and two furnaces in operation. The primary flicker measure used for this study is the unweighted rms value of the fluctuation envelope, expressed as a percentage of the rms line-to-ground voltage magnitude.

Tang, L. [ABB Power T and D Co., Inc., Raleigh, NC (United States)] [ABB Power T and D Co., Inc., Raleigh, NC (United States); Kolluri, S. [Entergy Services, New Orleans, LA (United States)] [Entergy Services, New Orleans, LA (United States); McGranaghan, M.F. [Electrotek Concepts, Inc., Knoxville, TN (United States)] [Electrotek Concepts, Inc., Knoxville, TN (United States)

1997-04-01T23:59:59.000Z

494

Low Voltage Electrostatic Actuation and Displacement Measurement through Resonant Drive Circuit.  

E-Print Network [OSTI]

??An electrostatic actuator driven by conventional voltage control and charge control requires high actuation voltage and suffers from the pull-in phenomenon that limits its operation… (more)

Park, Sangtak

2011-01-01T23:59:59.000Z

495

Categorical Exclusion (CX) Determination Proposed Action: Elliot 115kV/43.8kV Transmission Substation Construction and Elliot  

Broader source: Energy.gov (indexed) [DOE]

Elliot 115kV/43.8kV Transmission Substation Construction and Elliot Elliot 115kV/43.8kV Transmission Substation Construction and Elliot 43.8kV Transmission Line. Description of Proposed Action: The Central Power Electric Cooperative (Central Power) is proposing a new substation near Elliot, ND to be owned and operated by Western under Western's Valley City to Forman 115kV transmission line in addition to 8 miles of new 43.8kV transmission line to connect the new substation to Dakota Valley Electric's (a Central Power member) North Milnor substation. Number and Title of Categorical Exclusions Being Applied: 10 CFR 1021.410 Subpart D, Appendix B, B4.l1: Construction of electric power substations ... or modification of existing substations and support facilities. Regulatory Requirements for CX Determination: The DOE Guidelines for Compliance with

496

Constant voltage ultracapacitor  

Science Journals Connector (OSTI)

Ultracapacitors have attracted lots of attention recently due to their growing use in hybrid vehicles and in energy storage applications for the smart grid. A very undesirable feature of ultracapacitors is the fact that the voltage drops as the capacitor is discharged. DC-DC converters are employed at present to convert the voltage of the ultracapacitor to constant voltage; however these converters typically do not operate if the voltage of the ultracapacitor drops below 1?V. In addition DC-DC converters suffer from well-known size/efficiency tradeoffs. This paper introduces a novel new ultracapacitor that is characterized by constant voltage. The new ultracapacitor does not utilize familiar energy conversion principles. Rather operation depends on an embedded electromechanical system that actually alters the capacitance of the ultracapacitor as the device is discharged. Due to a simple proportionality relationship between charge capacitance and voltage the voltage remains constant. Theoretical and experimental investigations have shown that the embedded mechanism for altering the capacitance has an efficiency of 99% or higher.

Ezzat G. Bakhoum

2012-01-01T23:59:59.000Z

497

The Matrix Converter Drive Performance Under Abnormal Input Voltage Conditions  

E-Print Network [OSTI]

that generates variable magnitude variable frequency output voltage from the ac utility line. It has high power voltage disturbance related performance issues of the MC drive. Since the MC is a direct frequencyThe Matrix Converter Drive Performance Under Abnormal Input Voltage Conditions Jun-Koo Kang

Hava, Ahmet

498

Phase Transitions and High-Voltage Electrochemical Behavior of LiCoO2 Thin Films Grown by Pulsed Laser Deposition  

E-Print Network [OSTI]

Laser Deposition H. Xia,a L. Lu,b,z Y. S. Meng,c and G. Cederc, * a Advanced Materials for Micro behavior of LiCoO2 thin-film cathodes prepared by pulsed laser deposition are studied for charging voltages- discharge curves. Ex situ X-ray diffraction measurements confirm structural changes and a phase transition

Ceder, Gerbrand

499

The results of systems tests of the 500 kV busbar controllable shunting reactor in the Tavricheskaya substation  

Science Journals Connector (OSTI)

The results of systems tests of the 500 kV busbar magnetization-controllable shunting reactor (CSR), set up in the Tavricheskaya substation, including measurements of the quality of the...

S. I. Gusev; V. N. Karpov; A. N. Kiselev; V. I. Kochkin

2009-09-01T23:59:59.000Z

500

Intrinsic Surface Stability in LiMn2-xNixO4-d (x=0.45, 0.5) High Volt-age Spinel Materials for Lithium Ion Batteries  

SciTech Connect (OSTI)

This work reports the surface stability of the high voltage Li ion cathode LiMn2-xNixO4- (x= 0.5, 0.45) by comparing thin film and powder composite electrodes after cycling using X-ray photoelectron spectroscopy. The thin film electrodes offer the ability to probe the surface of the material without the need of a conductive agent and polymer binder typically used in composite electrodes. The results suggest that neither oxidation of PF6 to POF5 nor the decomposition of ethylene carbonate or dimethylene carbonate occurs on the surface of the spinel material. These results confirm the enhanced cycling stability and rate capability associated with the high voltage spinel material and suggests that the SEI layer forms due to the reaction of electrochemically inactive components in composite electrodes with the electrolyte.

Carroll, Kyler J [University of California, San Diego; Yang, Ming-Che [University of Florida, Gainesville; Veith, Gabriel M [ORNL; Dudney, Nancy J [ORNL; Meng, Ying Shirley [University of California, San Diego

2012-01-01T23:59:59.000Z