Powered by Deep Web Technologies
Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Qualification High Voltage Testing of Short Triax HTS Cables in the Laboratory  

SciTech Connect

In order to qualify the electrical insulation design of future HTS cables installed in the electric grid, a number of high voltage qualification tests are generally performed in the laboratory on either single-phase model cables and/or actual three-phase cable samples. Prior to installation of the 200-m Triax HTS cable at the American Electric Power Bixby substation near Columbus, Ohio, in September, 2006, such tests were conducted on both single-phase model cables made at ORNL and tri-axial cable sections cut off from cable made on a production run. The three-phase tri-axial design provides some specific testing challenges since the ground shield and three phases are concentric about a central former with each phase separated by dielectric tape insulation immersed in liquid nitrogen. The samples were successfully tested and qualified for partial discharge inception, AC withstand, and lightning impulse where voltage is applied to one phase with the other phases grounded. In addition one of the phase pairs was tested for dc withstand as a ldquoworst caserdquo scenario to simulate the effect of VLF (Very Low Frequency) tests on the actual cable installed at the Bixby site. The model and prototype cables will be described and the high voltage test results summarized.

James, David Randy [ORNL; Sauers, Isidor [ORNL; Ellis, Alvin R [ORNL; Tuncer, Enis [ORNL; Gouge, Michael J [ORNL; Demko, Jonathan A [ORNL; Duckworth, Robert C [ORNL; Rey, Christopher M [ORNL

2009-01-01T23:59:59.000Z

2

Partial discharge measurements on a high voltage direct current mass impregnated paper cable  

SciTech Connect

Partial discharge measurement has been a good tool for the quality assurance of cables under alternating voltage. With the growing interest in High Voltage Direct Current cables it seems therefore logical to extend this technique for use at direct voltage. The paper describes this technique as used on a HVDC cable with mass impregnated paper. The different phases of operation (no load, full load, cooling phase, etc.) are characterized by a different discharge behavior. Special attention is given to the dangerous cooling phase. Models have been developed which can explain the discharge patterns that were measured. This paper gives an insight in the electrical behavior of a HVDC cable with mass impregnated paper insulation.

Jeroense, M.J.P. [NKF KABEL B.V., Delft (Netherlands); Kreuger, F.H. [Delft Univ. of Technology (Netherlands)

1996-12-31T23:59:59.000Z

3

High Voltage Testing of a 5-meter Prototype Triaxial HTS Cable  

SciTech Connect

High voltage tests were performed on a 5-m long prototype triaxial HTS cable (supplied by Ultera) at ORNL in preparation for installation of a 200-m HTS cable of the same design at the AEP utility substation in Columbus, Ohio. The triaxial design comprises three concentric phases and shield around a common former with the phase to phase dielectric at cryogenic temperature. Advantages of this design include increased current density, a reduced amount of HTS tape needed, and reduced heat load. The phase to phase voltage will be 13.2 kVrms (7.6 kVrms to ground). Preliminary testing was done on half-scale and full-scale terminations which successfully passed AC withstand, partial discharge, and impulse tests. High voltage tests conducted on the 5-m cable with the cable straight and after bending 90 degrees were ac withstand to 39 kVrms, partial discharge inception, and a minimum of 10 positive and 10 negative lightning waveform impulses at 110 kV. Phase to phase insulation was tested by applying high voltage to each phase one at a time with all the other phases grounded. Partial discharge data will be presented. The 5-m prototype triaxial HTS cable passed all the HV tests performed, with a PD inception voltage significantly above the required voltage.

Sauers, Isidor [ORNL; James, David Randy [ORNL; Ellis, Alvin R [ORNL; Tuncer, Enis [ORNL; Pace, Marshall O [ORNL; Gouge, Michael J [ORNL; Demko, Jonathan A [ORNL; Lindsay, David T [ORNL

2007-01-01T23:59:59.000Z

4

Measurement of low radioactivity background in a high voltage cable by high resolution inductively coupled plasma mass spectrometry  

SciTech Connect

The measurement of naturally occurring low level radioactivity background in a high voltage (HV) cable by high resolution inductively coupled plasma mass spectrometry (HR ICP MS) is presented in this work. The measurements were performed at the Chemistry Service of the Gran Sasso National Laboratory. The contributions to the radioactive background coming from the different components of the heterogeneous material were separated. Based on the mass fraction of the cable, the whole contamination was calculated. The HR ICP MS results were cross-checked by gamma ray spectroscopy analysis that was performed at the low background facility STELLA (Sub Terranean Low Level Assay) of the LNGS underground lab using HPGe detectors.

Vacri, M. L. di; Nisi, S.; Balata, M. [Gran Sasso National Laboratory, Chemistry Service, SS 17bis km 18.910, 67100 Assergi (Aq) (Italy)] [Gran Sasso National Laboratory, Chemistry Service, SS 17bis km 18.910, 67100 Assergi (Aq) (Italy)

2013-08-08T23:59:59.000Z

5

Structure Design and Test Research on the Electrical Properties of High Voltage Instrumentation Cables for the Fusion Reactor  

Science Journals Connector (OSTI)

The HV instrumentation cable is an important route for the signals transmission from the superconducting magnets to the control system, it should be long term operated at around 4.2 K and withstand the high vo...

Qingsheng Gao; Xiongyi Huang; Yuntao Song; Weibin Xi…

2014-08-01T23:59:59.000Z

6

High conductance surge cable  

DOE Patents (OSTI)

An electrical cable for connecting transient voltage surge suppressors to electrical power panels. A strip of electrically conductive foil defines a longitudinal axis, with a length of an electrical conductor electrically attached to the metallic foil along the longitudinal axis. The strip of electrically conductive foil and the length of an electrical conductor are covered by an insulating material. For impedance matching purposes, triangular sections can be removed from the ends of the electrically conductive foil at the time of installation. 6 figs.

Murray, M.M.; Wilfong, D.H.; Lomax, R.E.

1998-12-08T23:59:59.000Z

7

High conductance surge cable  

DOE Patents (OSTI)

An electrical cable for connecting transient voltage surge suppressers to ectrical power panels. A strip of electrically conductive foil defines a longitudinal axis, with a length of an electrical conductor electrically attached to the metallic foil along the longitudinal axis. The strip of electrically conductive foil and the length of an electrical conductor are covered by an insulating material. For impedance matching purposes, triangular sections can be removed from the ends of the electrically conductive foil at the time of installation.

Murray, Matthew M. (Espanola, NM); Wilfong, Dennis H. (Brooksville, FL); Lomax, Ralph E. (Santa Fe, NM)

1998-01-01T23:59:59.000Z

8

On-line partial discharge monitoring system and data processing using WTST-NST filter for high voltage power cable  

Science Journals Connector (OSTI)

Defects inside insulation of HV XLPE cable accessories can lead to partial discharge (PD) activity. When PD activity happens, leakage current may flow through the grounded line. To acquire the PD current signal, one practicable and effective method is ... Keywords: MRD-MRR algorithm, adaptive WTST-NST filter, condition based maintenance(CBM), on-line monitoring, partial discharge, power cable, stationary noise interference

Hui Wang; Chengjun Huang; Li Zhang; Yong Qian; Junhua Liu; Linpeng Yao; Canxin Guo; Xiuchen Jiang

2009-07-01T23:59:59.000Z

9

High Temperature Superconducting Underground Cable  

SciTech Connect

The purpose of this Project was to design, build, install and demonstrate the technical feasibility of an underground high temperature superconducting (HTS) power cable installed between two utility substations. In the first phase two HTS cables, 320 m and 30 m in length, were constructed using 1st generation BSCCO wire. The two 34.5 kV, 800 Arms, 48 MVA sections were connected together using a superconducting joint in an underground vault. In the second phase the 30 m BSCCO cable was replaced by one constructed with 2nd generation YBCO wire. 2nd generation wire is needed for commercialization because of inherent cost and performance benefits. Primary objectives of the Project were to build and operate an HTS cable system which demonstrates significant progress towards commercial progress and addresses real world utility concerns such as installation, maintenance, reliability and compatibility with the existing grid. Four key technical areas addressed were the HTS cable and terminations (where the cable connects to the grid), cryogenic refrigeration system, underground cable-to-cable joint (needed for replacement of cable sections) and cost-effective 2nd generation HTS wire. This was the world’s first installation and operation of an HTS cable underground, between two utility substations as well as the first to demonstrate a cable-to-cable joint, remote monitoring system and 2nd generation HTS.

Farrell, Roger, A.

2010-02-28T23:59:59.000Z

10

3 - High temperature superconductor (HTS) cables  

Science Journals Connector (OSTI)

Abstract: Many superconductor applications such as rotating machinery, transformers and magnets with low inductance require high current cables with low AC losses. This chapter gives an overview on cabling techniques for the high temperature superconductors (HTS) BSCCO (2212), BSCCO (2223) and (RE)BCO. A short review is given of the basic properties of HTS wires and tapes and the basic requirements of HTS cables for different applications. Cabling concepts for the different HTS materials are presented, and current performance and AC loss behaviour are discussed. After a short description of remaining challenges and future trends, cabling techniques are summarized.

S.I. Schlachter; W. Goldacker

2012-01-01T23:59:59.000Z

11

High-voltage engineering  

E-Print Network (OSTI)

High-voltage engineering covers the application, the useful use and proper working of high voltages and high fields. Here we give some introductory examples, i.e., ‘septa’ and ‘kicker’ at the Large Hadron Collider (14 TeV), the Super Proton Synchrotron (450 GeV) and the Proton Synchrotron (26 GeV) accelerators as found at the European Orginization for Nuclear Research (CERN) today. We briefly cover the theoretical foundation (Maxwell equations) and aspects of numerical field simulation methods. Concepts relating to electrical fields, insulation geometry and medium and breakdown are introduced. We discuss ways of generating high voltages with examples of AC sources (50/60 Hz), DC sources, and pulse sources. Insulation and breakdown in gases, liquids, solids and vacuum are presented, including Paschen’s law (breakdown field and streamer breakdown). Applications of the above are discussed, in particular the general application of a transformer. We briefly discuss measurement techniques of partial disch...

Gaxiola, E

2006-01-01T23:59:59.000Z

12

High voltage pulse conditioning  

DOE Patents (OSTI)

Apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close.

Springfield, Ray M. (Sante Fe, NM); Wheat, Jr., Robert M. (Los Alamos, NM)

1990-01-01T23:59:59.000Z

13

High voltage DC power supply  

DOE Patents (OSTI)

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively. 7 figs.

Droege, T.F.

1989-12-19T23:59:59.000Z

14

High voltage DC power supply  

DOE Patents (OSTI)

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively.

Droege, Thomas F. (Batavia, IL)

1989-01-01T23:59:59.000Z

15

Graz University of Technology Institute of High Voltage Engineering and System Performance  

E-Print Network (OSTI)

.hspt@tugraz.at u www.hspt.tugraz.at Institute of High Voltage Engineering and System Performance Test Laboratory systems Test of insulators, fittings and accessories Testing of high voltage equipment Impulse voltage and current tests On-site-test of medium voltage cables Electrical methods in environmental technology

16

Test of two prototype high-temperature superconducting transmission cables  

SciTech Connect

Two 500-A class prototype high-temperature superconducting cables have been constructed by Southwire Company and tested at Oak Ridge National Laboratory (ORNL). In the first cable, no insulation was used to separate the individual HTS tapes. In the second cable, Kapton tape was used to insulate the HTS tapes between successive layers for the study of AC loss and current distribution. The cables were tested with both DC and AC currents in liquid nitrogen from 77 to 69 K. Both cables achieved DC critical current, I{sub c} greater than 500 A. A calorimetric technique that measures the cable temperature rise under ac currents was used to measure the ac loss of the cables. The un-insulated cable showed a cryoresistive behavior under the 60 Hz AC currents. The insulated cable started to show measurable loss at current where there was corresponding resistive loss.

Lue, J.W.; Lubell, M.S.; Kroeger, D.M.; Martin, P.M. [Oak Ridge National Lab., TN (United States); Demko, J.A.; Jones, E.C. [Oak Ridge Associated Universities, Inc., TN (United States); Sinha, U.; Hughey, R.L. [Southwire Co., Carrollton, GA (United States)

1996-10-01T23:59:59.000Z

17

An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.  

SciTech Connect

References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

Litzenberger, Wayne; Lava, Val

1994-08-01T23:59:59.000Z

18

High Temperature Superconductor Cable Concepts for Fusion Magnets.  

E-Print Network (OSTI)

??Three concepts of high temperature superconductor cables carrying kA currents (RACC, CORC and TSTC) are investigated, optimized and evaluated in the scope of their applicability… (more)

Barth, Christian

2013-01-01T23:59:59.000Z

19

Temperature controlled high voltage regulator  

DOE Patents (OSTI)

A temperature controlled high voltage regulator for automatically adjusting the high voltage applied to a radiation detector is described. The regulator is a solid state device that is independent of the attached radiation detector, enabling the regulator to be used by various models of radiation detectors, such as gas flow proportional radiation detectors.

Chiaro, Jr., Peter J. (Clinton, TN); Schulze, Gerald K. (Knoxville, TN)

2004-04-20T23:59:59.000Z

20

ABBGroup-1-High voltage lab  

E-Print Network (OSTI)

;Ā©ABBGroup-3- 3-Sep-07 Where does one use circuit breakers? High voltage (HV) circuit breakers are keyA DISTRIBUTION MEDIUM AND LOW VOLTAGE HV circuit breakers #12;Ā©ABBGroup-4- 3-Sep-07 When a breaker fails to interrupt the current... Fault arc at a disconnector Fault arc in a substation #12;Ā©ABBGroup-5- 3-Sep-07

Basse, Nils Plesner

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

CABLE TECHNOLOGY LABORATORIES, INC. DETERMINATION OF THRESHOLD...  

Office of Scientific and Technical Information (OSTI)

CABLE TECHNOLOGY LABORATORIES, INC. DETERMINATION OF THRESHOLD AND MAXIMUM OPERATING ELECTRIC STRESSES FOR SELECTED HIGH VOLTAGE INSULATIONS Investigation of Aged Polymeric...

22

High-Temperature Superconducting Cable Testing Gregory S. Boebinger, National High Magnetic Field Laboratory  

E-Print Network (OSTI)

High-Temperature Superconducting Cable Testing Gregory S. Boebinger, National High Magnetic Field-Temperature Superconducting (HTS) Cables are desirable for application in large high-field magnets (>20 T), especially when). Of the three HTS magnet cable concepts emerging, the Conductor On Round Core was the first that was tested

Weston, Ken

23

Cryogenic System for a High Temperature Superconducting Power Transmission Cable  

SciTech Connect

High-temperature superconducting (HTS) cable systems for power transmission are under development that will use pressurized liquid nitrogen to provide cooling of the cable and termination hardware. Southwire Company and Oak Ridge National Laboratory have been operating a prototype HTS cable system that contains many of the typical components needed for a commercial power transmission application. It is being used to conduct research in the development of components and systems for eventual commercial deployment. The cryogenic system was built by Air Products and Chemicals, Allentown, Pennsylvania, and can circulate up to 0.35 kg/s of liquid nitrogen at temperatures as low as 67 K at pressures of 1 to 10 bars. Sufficient cooling is provided for testing a 5-m-long HTS transmission cable system that includes the terminations required for room temperature electrical connections. Testing of the 5-m HTS transmission cable has been conducted at the design ac conditions of 1250 A and 7.5 kV line to ground. This paper contains a description of the essential features of the HTS cable cryogenic system and performance results obtained during operation of the system. The salient features of the operation that are important in large commercial HTS cable applications will be discussed.

Demko, J.A.; Gouge, M.J.; Hughey, R.L.; Lue, J.W.; Martin, R.; Sinha, U.; Stovall, J.P.

1999-07-12T23:59:59.000Z

24

Assessing Deterioration of ADSS Fiber Optic Cables  

E-Print Network (OSTI)

Assessing Deterioration of ADSS Fiber Optic Cables Due to Corona Discharge Final Project Report of ADSS Fiber Optic Cables Due to Corona Discharge Final Project Report George G. Karady, Project Leader-Supporting) fiber optic cables installed on high voltage lines. The high electric field on those lines generates

25

Performance of reduced wall EPR insulated medium voltage power cables. Pat 1: Electrical characteristics  

SciTech Connect

Paper insulated lead covered cables (PILC) have had a long and successful heritage. After almost 100 years, this design of cable is still in operation and continues to be manufactured. However, utilities are now looking for a reliable replacement for PILC cables. This is due to two primary reasons: (1) difficulty in installing and maintaining this type of cable and (2) increasing pressure to replace these cables due to environmental concerns. To date diameter limitations of conventional extruded dielectric cables has impeded their replacement in existing PILC conduits. This paper describes a study for the evaluation for reliably reducing the insulation thickness to achieve a lower diameter cable to effectively replace PILC cable in existing conduits. Part 1 of the investigation reviews the theory of insulation wall determination and the test program carried out to evaluate electrical performance of reduced wall EPR cables. Additionally, cable design concepts and constructions are discussed. In Part 2 the mechanical performance on conventional and reduced wall EPR insulated cables are evaluated. This is reported in a separate paper.

Cinquemani, P.L.; Wen, Y.; Kuchta, F.L.; Doench, C. [Pirelli Cable Corp., Lexington, SC (United States)] [Pirelli Cable Corp., Lexington, SC (United States)

1997-04-01T23:59:59.000Z

26

High-Temperature Superconductivity Cable Demonstration Projects  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Temperature Temperature Superconductivity Cable Demonstration Projects Superconductivity Power Equipment www.oe.energy.gov Phone: 202-586-1411 Office of Electricity Delivery and Energy Reliability, OE-1 U.S. Department of Energy - 1000 Independence Avenue, SW - Washington, DC 20585. Plugging America Into the Future of Power "A National Effort to Introduce New Technology into the Power Delivery Infrastructure" "In order to meet President Obama's ambitious energy goals, we must modernize the nation's electrical grid to improve the transmission, storage and reliability of clean energy across the country and help to move renewable energy from the places it can be produced to the places it can be used. The Department of Energy is working with industry partners to develop the

27

High voltage RF feedthrough bushing  

DOE Patents (OSTI)

Described is a multi-element, high voltage radio frequency bushing for trmitting RF energy to an antenna located in a vacuum container. The bushing includes a center conductor of complex geometrical shape, an outer coaxial shield conductor, and a thin-walled hollow truncated cone insulator disposed between central and outer conductors. The shape of the center conductor, which includes a reverse curvature portion formed of a radially inwardly directed shoulder and a convex portion, controls the uniformity of the axial surface gradient on the insulator cone. The outer shield has a first substantially cylindrical portion and a second radially inwardly extending truncated cone portion.

Grotz, Glenn F. (Huntington Station, NY)

1984-01-01T23:59:59.000Z

28

Performance of reduced wall EPR insulated medium voltage power cables. Part 2: Mechanical characteristics  

SciTech Connect

For the replacement of paper insulated lead covered cables (PILC) reduced insulation wall designs have been developed. They provide a reliable lower diameter cable design for installation in existing PILC conduits. Representing Part 2 of the investigation, this paper presents the results of mechanical testing conducted on both reduced and full wall EPR insulated cables. Both jacketed and non-jacketed cable designs have been subjected to mechanical pulling forces which greatly exceed recommended industry limitations, followed by electrical testing to ascertain cable performance. The results of this study conclude that reduced wall EPR insulated cables can safely withstand the same pulling forces as recommended for conventional walls and can be designed for installation under the same pulling limitations.

Wen, Y.; Cinquemani, P.L. [Pirelli Cable Corp., Lexington, SC (United States)

1997-04-01T23:59:59.000Z

29

High Voltage Electrolyte for Lithium Batteries  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

battery using high voltage high energy cathode materials to enable large-scale, cost competitive production of the next generation of electric-drive vehicles. To...

30

High voltage load resistor array  

DOE Patents (OSTI)

A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

Lehmann, Monty Ray (Smithfield, VA)

2005-01-18T23:59:59.000Z

31

Radiation Testing of a Low Voltage Silicone Nuclear Power Plant Cable.  

SciTech Connect

This report summarizes the results generated in FY13 for cable insulation in support of DOE's Light Water Reactor Sustainability (LWRS) Program, in collaboration with the US- Argentine Binational Energy Working Group (BEWG). A silicone (SiR) cable, which was stored in benign conditions for ~30 years, was obtained from Comision Nacional de Energia Atomica (CNEA) in Argentina. Physical property testing was performed on the as-received cable. This cable was artificially aged to assess behavior with additional analysis. SNL observed appreciable tensile elongation values for all cable insulations received, indicative of good mechanical performance. Of particular note, the work presented here provides correlations between measured tensile elongation and other physical properties that may be potentially leveraged as a form of condition monitoring (CM) for actual service cables. It is recognized at this point that the polymer aging community is still lacking the number and types of field returned materials that are desired, but SNL -- along with the help of others -- is continuing to work towards that goal. This work is an initial study that should be complimented with location- mapping of environmental conditions of CNEA plant conditions (dose and temperature) as well as retrieval, analysis, and comparison with in-service cables.

Bernstein, Robert

2014-08-01T23:59:59.000Z

32

Radiation Testing of a Low Voltage Silicone Nuclear Power Plant Cable.  

SciTech Connect

This report summarizes the results generated in FY13 for cable insulation in support of the Department of Energy's Light Water Reactor Sustainability (LWRS) Program, in collaboration with the US-Argentine Binational Energy Working Group (BEWG). A silicone (SiR) cable, which was stored in benign conditions for ~30 years, was obtained from Comision Nacional de Energia Atomica (CNEA) in Argentina with the approval of NA-SA (Nucleoelectrica Argentina Sociedad Anonima). Physical property testing was performed on the as-received cable. This cable was artificially aged to assess behavior with additional analysis. SNL observed appreciable tensile elongation values for all cable insulations received, indicative of good mechanical performance. Of particular note, the work presented here provides correlations between measured tensile elongation and other physical properties that may be potentially leveraged as a form of condition monitoring (CM) for actual service cables. It is recognized at this point that the polymer aging community is still lacking the number and types of field returned materials that are desired, but Sandia National Laboratories (SNL) -- along with the help of others -- is continuing to work towards that goal. This work is an initial study that should be complimented with location-mapping of environmental conditions of Argentinean plant conditions (dose and temperature) as well as retrieval, analysis, and comparison with in- service cables.

White II, Gregory Von; Schroeder, John Lee.; Sawyer, Patricia Sue.; Wichhart, Derek; Mata, Guillermo Adrian; Zorrilla, Jorge; Bernstein, Robert

2014-09-01T23:59:59.000Z

33

Low Cost, High Impact Cable Condition Monitoring System Improves...  

Office of Science (SC) Website

and control. To address cable aging, the nuclear industry has been looking for a test system that can help with automated maintenance and condition monitoring of cables....

34

Development of High Voltage Electron Microscope  

Science Journals Connector (OSTI)

......Cockcroft Walton Type High Voltage Generator. O Power Line O Fig. 4...pressure in the tank to the atmospheric pressure by removing freon...pump using liquid nitrogen. Water buffer and liquid nitrogen...base plate of high voltage generator. Four poles stand on this......

Shinjiro KATAGIRI; Hirokazu KIMURA; Susumu OZASA; Kazumi SHIRAISHI

1969-01-01T23:59:59.000Z

35

Limitations of High-Voltage Insulation  

Science Journals Connector (OSTI)

... materials such as impregnated paper. The important electrical properties of the materials used for the insulation of high-voltage circuits are conductivity and electric strength. The conductivity measures the ability ... a million times between themselves, but they are all classified as available for high-voltage insulation.

1938-01-08T23:59:59.000Z

36

Fully synthetic taped insulation cables  

DOE Patents (OSTI)

The present invention is a cable which, although constructed from inexpensive polyolefin tapes and using typical impregnating oils, furnishes high voltage capability up to 765 kV, and has such excellent dielectric characteristics and heat transfer properties that it is capable of operation at capacities equal to or higher than presently available cables at a given voltage. This is accomplished by using polyethylene, polybutene or polypropylene insulating tape which has been specially processed to attain properties which are not generally found in these materials, but are required for their use in impregnated electrical cables. Chief among these properties is compatibility with impregnating oil.

Forsyth, E.B.; Muller, A.C.

1983-07-15T23:59:59.000Z

37

High Voltage Safety Act | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High Voltage Safety Act High Voltage Safety Act High Voltage Safety Act < Back Eligibility Commercial Construction Developer General Public/Consumer Industrial Installer/Contractor Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Georgia Program Type Safety and Operational Guidelines Siting and Permitting The purpose of the High Voltage Safety Act is to prevent injury to persons and property and interruptions of utility service resulting from accidental or inadvertent contact with high-voltage electric lines by providing that no work shall be done in the vicinity of such lines unless and until the owner or operator thereof has been notified of such work and has taken the appropriate safety measures. The Georgia Public Service Commission requires

38

ABBGroup-1-High voltage lab  

E-Print Network (OSTI)

A DISTRIBUTION MEDIUM AND LOW VOLTAGE HV circuit breakers #12;Ā©ABBGroup-4- 3-Sep-07 When a breaker fails to interrupt the current... Fault arc at a disconnector Fault arc in a substation #12;Ā©ABBGroup-5- 3-Sep-07/costs A detailed understanding of arc physics and fluid dynamics is necessary for the development of HV circuit

Basse, Nils Plesner

39

Vehicle Technologies Office Merit Review 2014: High-Voltage Solid...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles Vehicle Technologies Office Merit Review 2014: High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...

40

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2013 DOE Hydrogen and Fuel Cells Program and...

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2012 DOE Hydrogen and Fuel Cells Program and...

42

Fully synthetic taped insulation cables  

DOE Patents (OSTI)

A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

Forsyth, Eric B. (Brookhaven, NY); Muller, Albert C. (Center Moriches, NY)

1984-01-01T23:59:59.000Z

43

Modular high voltage power supply for chemical analysis  

DOE Patents (OSTI)

A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2010-05-04T23:59:59.000Z

44

High voltage overhead long transmission line design and fault analysis.  

E-Print Network (OSTI)

??The goal of this project is to design a reliable high voltage overhead long transmission line that satisfies specific design criteria including voltage regulation, efficiency,… (more)

Elzain, Mohamed Ali

2011-01-01T23:59:59.000Z

45

Rational design of high-current cable-in-conduit superconductors  

SciTech Connect

Cable-in-conduit superconductors are composed of a cable of many fine composite strands encased in a strong, protective jacket, with helium coolant filling the interstices of the cable. Because of the high degree of subdivision of the composite and its consequent large cooled surface, such conductors are capable of stable operation at quite high current densities. The designer of such conductors is frequently given the field at the conductor and the overall current density and asked to specify the remaining variables of the conductor (e.g., the strand diameter, the hydraulic path length, the void fraction of the cable, and the Cu/SC ratio). This paper outlines a rational procedure for determining the most problematic variables, the two composition variables that determine the proportions of copper, superconductor, and helium in the cable space. All other variables of the conductor are assumed known. 14 refs., 8 figs.

Dresner, L.

1989-01-01T23:59:59.000Z

46

The US market for high-temperature superconducting wire in transmission cable applications  

SciTech Connect

Telephone interviews were conducted with 23 utility engineers concerning the future prospects for high-temperature superconducting (HTS) transmission cables. All have direct responsibility for transmission in their utility, most of them in a management capacity. The engineers represented their utilities as members of the Electric Power Research Institute`s Underground Transmission Task Force (which has since been disbanded). In that capacity, they followed the superconducting transmission cable program and are aware of the cryogenic implications. Nineteen of the 23 engineers stated the market for underground transmission would grow during the next decade. Twelve of those specified an annual growth rate; the average of these responses was 5.6%. Adjusting that figure downward to incorporate the remaining responses, this study assumes an average growth rate of 3.4%. Factors driving the growth rate include the difficulty in securing rights-of-way for overhead lines, new construction techniques that reduce the costs of underground transmission, deregulation, and the possibility that public utility commissions will allow utilities to include overhead costs in their rate base. Utilities have few plans to replace existing cable as preventive maintenance, even though much of the existing cable has exceeded its 40-year lifetime. Ten of the respondents said the availability of a superconducting cable with the same life-cycle costs as a conventional cable and twice the ampacity would induce them to consider retrofits. The respondents said a cable with those characteristics would capture 73% of their cable retrofits.

Forbes, D.

1996-04-01T23:59:59.000Z

47

Electro-optic high voltage sensor  

DOE Patents (OSTI)

A small sized electro-optic voltage sensor capable of accurate measurement of high levels of voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation into the sensor. A polarization beam displacer serves as a filter to separate the input beam into two beams with orthogonal linear polarizations. The beam displacer is oriented in such a way as to rotate the linearly polarized beams such that they enter a Pockels crystal having at a preferred angle of 45 degrees. The beam displacer is therefore capable of causing a linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels electro-optic effect induces a differential phase shift on the major and minor axes of the input beam as it travels through the Pockels crystal, which causes the input beam to be elliptically polarized. A reflecting prism redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization representing the major and minor axes. The system may include a detector for converting the output beams into electrical signals, and a signal processor for determining the voltage based on an analysis of the output beams. The output beams are amplitude modulated by the frequency of the electric field and the amplitude of the output beams is proportional to the magnitude of the electric field, which is related to the voltage being measured.

Davidson, James R. (Idaho Falls, ID); Seifert, Gary D. (Idaho Falls, ID)

2002-01-01T23:59:59.000Z

48

High voltage electric substation performance in earthquakes  

SciTech Connect

This paper examines the performance of several types of high voltage substation equipment in past earthquakes. Damage data is provided in chart form. This data is then developed into a tool for estimating the performance of a substation subjected to an earthquake. First, suggests are made about the development of equipment class fragility curves that represent the expected earthquake performance of different voltages and types of equipment. Second, suggestions are made about how damage to individual pieces of equipment at a substation likely affects the post-earthquake performance of the substation as a whole. Finally, estimates are provided as to how quickly a substation, at various levels of damage, can be restored to operational service after the earthquake.

Eidinger, J. [G and E Engineering Systems, Oakland, CA (United States); Ostrom, D. [Southern California Edison, Rosemead, CA (United States); Matsuda, E. [Pacific Gas and Electric, San Francisco, CA (United States)

1995-12-31T23:59:59.000Z

49

A High Voltage Direct Current Generator  

Science Journals Connector (OSTI)

When powdered materials are blown through metal tubes by means of compressed air considerable quantities of electricity are produced by contact electrification. It was found that 6×10-5 coulombs could be produced per gram of diatomaceous earth, a form of silica, blown through a short length of copper tube. A generator of extremely high voltage is proposed, and a small scale model of such a generator is described, by means of which currents of 8×10-5 amperes at 260 kilovolts were generated.

Richard E. Vollrath

1932-10-15T23:59:59.000Z

50

Safe epoxy encapsulant for high voltage magnetics  

SciTech Connect

This paper describes the use of Formula 456, an aliphatic amine cured epoxy for impregnating coils and high voltage transformers. Sandia has evaluated a number of MDA-free epoxy encapsulants which relied on either anhydride or other aromatic amine curing agents. The use of aliphatic amine curing agents was more recently evaluated and has resulted in the definition of Formula 456 resin. Methylene dianiline (MDA) has been used for more than 20 years as the curing agent for various epoxy formulations throughout the Department of Energy and much of industry. Sandia National Laboratories began the process of replacing MDA with other formulations because of regulations imposed by OSHA on the use of MDA. OSHA has regulated MDA because it is a suspect carcinogen. Typically the elimination of OSHA-regulated materials provides a rare opportunity to qualify new formulations in a range of demanding applications. It was important to take full advantage of that opportunity, although the associated materials qualification effort was costly. Small high voltage transformers are one of those demanding applications. The successful implementation of the new formulation for high reliability transformers will be described. The test results that demonstrate the parts are qualified for use in DOE weapon systems will be presented.

Sanchez, R.O.; Archer, W.E.

1998-01-01T23:59:59.000Z

51

Accelerator System Development at High Voltage Engineering  

SciTech Connect

Throughout the years, HVE has continuously extended the capabilities of its accelerator systems to meet the rising demands from a diverse field of applications, among which are deep level ion implantation, micro-machining, neutron production for biomedical research, isotope production or accelerator mass spectrometry. Characteristic for HVE accelerators is the coaxial construction of the all solid state power supply around the acceleration tubes. With the use of solid state technology, the accelerators feature high stability and very low ripple. Terminal voltages range from 1 to 6 MV for HVE Singletrons and Tandetrons. The high-current versions of these accelerators can provide ion beams with powers of several kW. In the last years, several systems have been built with terminal voltages of 1.25 MV, 2 MV and 5 MV. Recently, the first system based on a 6 MV Tandetron has passed the factory tests. In this paper we describe the characteristics of the HVE accelerator systems and present as example recent systems.

Klein, M. G.; Gottdang, A.; Haitsma, R. G.; Mous, D. J. W. [High Voltage Engineering Europa B.V., P.O. Box 99, Amersfoort 3800 AB (Netherlands)

2009-03-10T23:59:59.000Z

52

Low voltage amplifier architecture for high speed switched capacitor circuits  

E-Print Network (OSTI)

This work concentrates on circuit realization of high speed and low voltage switched capacitor circuits, with emphasis on the operational transconductance amplifier (OTA). An overview of switched capacitor circuits is given. Speed and voltage...

Shankar, Asit

2012-06-07T23:59:59.000Z

53

fault diagnosis of a high voltage transmission line using waveform ...  

E-Print Network (OSTI)

Oct 4, 2013 ... FAULT DIAGNOSIS OF A HIGH VOLTAGE TRANSMISSION LINE USING ... Fault types such as single line to ground, line to line, double line to ...

Ripunjoy Phukan

2013-10-04T23:59:59.000Z

54

Critical current and instability threshold measurement of Nb3Sn cables for high field accelerator magnets  

SciTech Connect

Rutherford-type cables made of high critical current Nb{sub 3}Sn strands are being used in several laboratories for developing new generation superconducting magnets for present and future accelerators and upgrades. Testing of cable short samples is an important part of these R&D programs and the instability problem found in some short model magnets at Fermilab made these tests even more significant. Fermilab in collaboration with BNL, CERN and LBNL has developed sample holders and sample preparation infrastructure and procedures for testing Nb{sub 3}Sn cable short samples at BNL and CERN test facilities. This paper describes the sample holders, sample preparation and instrumentation, and test results. Several samples made of MJR or PIT strands 1 mm in diameter have been tested. Some samples were unstable (i.e. quenched at low transport currents) at low fields and reached the critical surface at higher fields.

Ambrosio, G.; Andreev, N.; /Fermilab; Bartlett, S.E.; /LBL, Berkeley; Barzi, E.; /Fermilab; Denarie, C.-H.; /CERN; Dietderich, D.; /LBL, Berkeley; Ghosh, A.K.; /Brookhaven; Verweij, A.P.; /CERN; Zlobin, A.V.; /Fermilab

2004-11-01T23:59:59.000Z

55

Power superconducting power transmission cable  

DOE Patents (OSTI)

The present invention is for a compact superconducting power transmission cable operating at distribution level voltages. The superconducting cable is a conductor with a number of tapes assembled into a subconductor. These conductors are then mounted co-planarly in an elongated dielectric to produce a 3-phase cable. The arrangement increases the magnetic field parallel to the tapes thereby reducing ac losses.

Ashworth, Stephen P. (Cambridge, GB)

2003-01-01T23:59:59.000Z

56

Measurement of high voltage using Rutherford backscattering spectrometry  

E-Print Network (OSTI)

A novel variation of Rutherford Backscattering Spectrometry (RBS) has been utilized to measure a high voltage collected on an aluminum target by Direct Energy Conversion. The maximum high voltage on the target was measured to be 97.5 kV +/- 2 kV...

Abrego, Celestino Pete

2007-04-25T23:59:59.000Z

57

The Cavendish high-voltage laboratory 1935–39  

Science Journals Connector (OSTI)

...the period covered. Nuclear Transmutation|Cavendish...development of high-voltage nuclear transmutation equipment...experimental work in nuclear physics though he continued...a new high-voltage accelerator therefore fell mainly...doubler circuit with six vacuum rectifiers forming a...

1999-01-01T23:59:59.000Z

58

Fault Location and Incipient Fault Detection in Distribution Cables.  

E-Print Network (OSTI)

??A set of fault location algorithms for underground medium voltage cables, two incipient fault detection schemes for distribution cables and a state estimation method for… (more)

Xu, Zhihan

2011-01-01T23:59:59.000Z

59

Living and Working Safely Around High-Voltage Power Lines.  

SciTech Connect

High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

United States. Bonneville Power Administration.

2001-06-01T23:59:59.000Z

60

Electrical system architecture having high voltage bus  

DOE Patents (OSTI)

An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

Hoff, Brian Douglas (East Peoria, IL); Akasam, Sivaprasad (Peoria, IL)

2011-03-22T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage put under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1996-01-01T23:59:59.000Z

62

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 figs.

Shimer, D.W.; Lange, A.C.

1996-10-15T23:59:59.000Z

63

High-voltage air-core pulse transformers  

SciTech Connect

General types of air core pulse transformers designed for high voltage pulse generation and energy transfer applications are discussed with special emphasis on pulse charging systems which operate up to the multi-megavolt range. The design, operation, dielectric materials, and performance are described. It is concluded that high voltage air core pulse transformers are best suited to applications outside the normal ranges of conventional magnetic core transformers. In general these include charge transfer at high power levels and fast pulse generation with comparatively low energy. When properly designed and constructed, they are capable of delivering high energy transfer efficiency and have demonstrated superior high voltage endurance. The principal disadvantage of high voltage air core transformers is that they are not generally available from commercial sources. Consequently, the potential user must become thoroughly familiar with all aspects of design, fabrication and system application before he can produce a high performance transformer system. (LCL)

Rohwein, G. J.

1981-01-01T23:59:59.000Z

64

Optically triggered high voltage switch network and method for switching a high voltage  

DOE Patents (OSTI)

An optically triggered solid state switch and method for switching a high voltage electrical current. A plurality of solid state switches (350) are connected in series for controlling electrical current flow between a compensation capacitor (112) and ground in a reactive power compensator (50, 50') that monitors the voltage and current flowing through each of three distribution lines (52a, 52b and 52c), which are supplying three-phase power to one or more inductive loads. An optical transmitter (100) controlled by the reactive power compensation system produces light pulses that are conveyed over optical fibers (102) to a switch driver (110') that includes a plurality of series connected optical triger circuits (288). Each of the optical trigger circuits controls a pair of the solid state switches and includes a plurality of series connected resistors (294, 326, 330, and 334) that equalize or balance the potential across the plurality of trigger circuits. The trigger circuits are connected to one of the distribution lines through a trigger capacitor (340). In each switch driver, the light signals activate a phototransistor (300) so that an electrical current flows from one of the energy reservoir capacitors through a pulse transformer (306) in the trigger circuit, producing gate signals that turn on the pair of serially connected solid state switches (350).

El-Sharkawi, Mohamed A. (Renton, WA); Andexler, George (Everett, WA); Silberkleit, Lee I. (Mountlake Terrace, WA)

1993-01-19T23:59:59.000Z

65

High-voltage supply for backward-wave tube  

SciTech Connect

A high-current high-voltage supply for a backward-wave tube is described that uses a generalppurpose semiconductor converter with pulse-width modulation and two-stage regulation. The load current is up to 250 mA for load voltages of from 0.5 to 4.5 kV. The voltage staiblity is less than or equal to 5 x 10/sup -6/. the root-mean-square output ripple is less than or equal to 2 x 10/sup -6// The supply is equipped with high-speed (5 usec) load-breakdown protection.

Bryvkhanov, A.N.; Kosarev, P.M.; Latushkin, S.T.; Yudin, L.I.

1986-04-01T23:59:59.000Z

66

Method and apparatus for electrical cable testing by pulse-arrested spark discharge  

DOE Patents (OSTI)

A method for electrical cable testing by Pulse-Arrested Spark Discharge (PASD) uses the cable response to a short-duration high-voltage incident pulse to determine the location of an electrical breakdown that occurs at a defect site in the cable. The apparatus for cable testing by PASD includes a pulser for generating the short-duration high-voltage incident pulse, at least one diagnostic sensor to detect the incident pulse and the breakdown-induced reflected and/or transmitted pulses propagating from the electrical breakdown at the defect site, and a transient recorder to record the cable response. The method and apparatus are particularly useful to determine the location of defect sites in critical but inaccessible electrical cabling systems in aging aircraft, ships, nuclear power plants, and industrial complexes.

Barnum, John R. (Albuquerque, NM); Warne, Larry K. (Albuquerque, NM); Jorgenson, Roy E. (Albuquerque, NM); Schneider, Larry X. (Albuquerque, NM)

2005-02-08T23:59:59.000Z

67

Solid state safety jumper cables  

DOE Patents (OSTI)

Solid state jumper cables for connecting two batteries in parallel, having two bridge rectifiers for developing a reference voltage, a four-input decoder for determining which terminals are to be connected based on a comparison of the voltage at each of the four terminals to the reference voltage, and a pair of relays for effecting the correct connection depending on the determination of the decoder. No connection will be made unless only one terminal of each battery has a higher voltage than the reference voltage, indicating "positive" terminals, and one has a lower voltage than the reference voltage, indicating "negative" terminals, and that, therefore, the two high voltage terminals may be connected and the two lower voltage terminals may be connected. Current flows once the appropriate relay device is closed. The relay device is preferably a MOSFET (metal oxide semiconductor field effect transistor) combined with a series array of photodiodes that develop MOSFET gate-closing potential when the decoder output causes an LED to light.

Kronberg, James W. (353 Church Rd., Beech Island, SC 29841)

1993-01-01T23:59:59.000Z

68

Solid state safety jumper cables  

DOE Patents (OSTI)

Solid state jumper cables for connecting two batteries in parallel, having two bridge rectifiers for developing a reference voltage, a four-input decoder for determining which terminals are to be connected based on a comparison of the voltage at each of the four terminals to the reference voltage, and a pair of relays for effecting the correct connection depending on the determination of the decoder. No connection will be made unless only one terminal of each battery has a higher voltage than the reference voltage, indicating positive'' terminals, and one has a lower voltage than the reference voltage, indicating negative'' terminals, and that, therefore, the two high voltage terminals may be connected and the two lower voltage terminals may be connected. Current flows once the appropriate relay device is closed. The relay device is preferably a MOSFET (metal oxide semiconductor field effect transistor) combined with a series array of photodiodes that develop MOSFET gate-closing potential when the decoder output causes an LED to light.

Kronberg, J.W.

1993-02-23T23:59:59.000Z

69

High Voltage Electrolytes for Li-ion Batteries | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electrolytes for Li-ion Batteries High Voltage Electrolytes for Li-ion Batteries 2011 DOE Hydrogen and Fuel Cells Program, and Vehicle Technologies Program Annual Merit Review and...

70

High Voltage Electrolytes for Li-ion Batteries | Department of...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

in Support of 5 V Li-ion Chemistries Vehicle Technologies Office Merit Review 2014: Fluorinated Electrolyte for 5-V Li-Ion Chemistry High Voltage Electrolyte for Lithium Batteries...

71

High voltage dry-type air-core shunt reactors  

Science Journals Connector (OSTI)

Dry-type air-core shunt reactors are now being ... systems to limit overvoltages. Recently, high voltage dry-type air-core shunt reactors have been designed, ... transient overvoltages and electrical and magnetic...

Klaus Papp; Michael R. Sharp…

2014-11-01T23:59:59.000Z

72

High-speed low-voltage ultraviolet light source  

Science Journals Connector (OSTI)

A novel quasi-spark gap has been designed and constructed with high-speed and low-spark voltage characteristics. Ultraviolet light generating sparks can be operated at a rate of up to...

Huang, L; Hsu, S C; Kwok, H S

1984-01-01T23:59:59.000Z

73

Detonator cable initiation system safety investigation: Consequences of energizing the detonator and actuator cables  

SciTech Connect

This study was performed to explore and assess the worst-case response of a W89-type weapons system, damaged so as to expose detonator and/or detonator safing strong link (DSSL) cables to the most extreme, credible lightning-discharge, environment. The test program used extremely high-current-level, fast-rise-time (1- to 2-{mu}s) discharges to simulate lightning strikes to either the exposed detonator or DSSL cables. Discharges with peak currents above 700 kA were required to explode test sections of detonator cable and launch a flyer fast enough potentially to detonate weapon high explosive (HE). Detonator-safing-strong-link (DSSL) cables were exploded in direct contact with hot LX-17 and Ultrafine TATB (UFTATB). At maximum charging voltage, the discharge system associated with the HE firing chamber exploded the cables at more than 600-kA peak current; however, neither LX-17 nor UFTATB detonated at 250{degree}C. Tests showed that intense surface arc discharges of more than 700 kA/cm in width across the surface of hot UFTATB [generally the more sensitive of the two insensitive high explosives (IHE)] could not initiate this hot IHE. As an extension to this study, we applied the same technique to test sections of the much-narrower but thicker-cover-layer W87 detonator cable. These tests were performed at the same initial stored electrical energy as that used for the W89 study. Because of the narrower cable conductor in the W87 cables, discharges greater than 550-kA peak current were sufficient to explode the cable and launch a fast flyer. In summary, we found that lightning strikes to exposed DSSL cables cannot directly detonate LX-17 or UFTATB even at high temperatures, and they pose no HE safety threat.

Osher, J.; Chau, H.; Von Holle, W.

1994-03-01T23:59:59.000Z

74

Characterization of a high-temperature superconducting conductor on round core cables in magnetic fields up to 20 T  

SciTech Connect

The next generation of high-ļ¬eld magnets that will operate at magnetic ļ¬elds substantially above 20 T, or at temperatures substantially above 4.2 K, requires high-temperature superconductors (HTS). Conductor on round core (CORC) cables, in which RE-Ba{sub 2}Cu{sub 3}O{sub 7-{delta}} (RE = rare earth) (REBCO) coated conductors are wound in a helical fashion on a fl?exible core, are a practical and versatile HTS cable option for low-inductance, high-field magnets. We performed the first tests of CORC magnet cables in liquid helium in magnetic fields of up to 20 T. A record critical current I{sub c} of 5021 A was measured at 4.2 K and 19 T. In a cable with an outer diameter of 7.5 mm, this value corresponds to an engineering current density J{sub e} of 114 A mm{sup -2} , the highest J{sub e} ever reported for a superconducting cable at such high magnetic fields. Additionally, the first magnet wound from an HTS cable was constructed from a 6 m-long CORC cable. The 12-turn, double-layer magnet had an inner diameter of 9 cm and was tested in a magnetic field of 20 T, at which it had an I{sub c} of 1966 A. The cables were quenched repetitively without degradation during the measurements, demonstrating the feasibility of HTS CORC cables for use in high-field magnet applications.

van der Laan, Danko [Advanced Conductor Technologies; Noyes, Patrick [National High Magnetic Field Laboratory; Miller, George [National High Magnetic Field Laboratory; Weijers, Hubertus [National High Magnetic Field Laboratory; Willering, Gerard [CERN

2013-02-13T23:59:59.000Z

75

High voltage electrical amplifier having a short rise time  

DOE Patents (OSTI)

A circuit, comprising an amplifier and a transformer is disclosed that produces a high power pulse having a fast response time, and that responds to a digital control signal applied through a digital-to-analog converter. The present invention is suitable for driving a component such as an electro-optic modulator with a voltage in the kilovolt range. The circuit is stable at high frequencies and during pulse transients, and its impedance matching circuit matches the load impedance with the output impedance. The preferred embodiment comprises an input stage compatible with high-speed semiconductor components for amplifying the voltage of the input control signal, a buffer for isolating the input stage from the output stage; and a plurality of current amplifiers connected to the buffer. Each current amplifier is connected to a field effect transistor (FET), which switches a high voltage power supply to a transformer which then provides an output terminal for driving a load. The transformer comprises a plurality of transmission lines connected to the FETs and the load. The transformer changes the impedance and voltage of the output. The preferred embodiment also comprises a low voltage power supply for biasing the FETs at or near an operational voltage.

Christie, David J. (Pleasanton, CA); Dallum, Gregory E. (Livermore, CA)

1991-01-01T23:59:59.000Z

76

Design & Fabrication of a High-Voltage Photovoltaic Cell  

SciTech Connect

Silicon photovoltaic (PV) cells are alternative energy sources that are important in sustainable power generation. Currently, applications of PV cells are limited by the low output voltage and somewhat low efficiency of such devices. In light of this fact, this project investigates the possibility of fabricating high-voltage PV cells on float-zone silicon wafers having output voltages ranging from 50 V to 2000 V. Three designs with different geometries of diffusion layers were simulated and compared in terms of metal coverage, recombination, built-in potential, and conduction current density. One design was then chosen and optimized to be implemented in the final device design. The results of the simulation serve as a feasibility test for the design concept and provide supportive evidence of the effectiveness of silicon PV cells as high-voltage power supplies.

Felder, Jennifer; /North Carolina State U. /SLAC

2012-09-05T23:59:59.000Z

77

Cryogenic Cables  

Science Journals Connector (OSTI)

Cryogenic Cables ... power underground with superconducting cables at cryogenic temperatures. ... Already, cryogenic cooling of existing cables has been proposed to decrease ohmic resistance and thereby increase powercarrying capacities by as much as 10 times. ...

1969-06-16T23:59:59.000Z

78

High Temperature, High Voltage Fully Integrated Gate Driver Circuit  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

driver circuit, 5-V on- chip voltage regulator, short-circuit protection, undervoltage lockout, bootstrap capacitor, dead time controller and temperature sensor * 0.8-micron,...

79

Design issues for high voltage converters for ion engines  

SciTech Connect

A design strategy is presented for a power converter for a high voltage ion engine for a spacecraft application. Various design issues such as appropriate topologies and control methods are considered. In this particular instance it was determined that a full bridge converter with phase shift gating and voltage mode control provided an efficient system with a minimum of electromagnetic interference. This system can be implemented in a straightforward manner, and it is relatively easy to protect from faults at the output.

King, R.J.; Stuart, T.A. [Univ. of Toledo, OH (United States)

1995-12-31T23:59:59.000Z

80

Polymerizable Additive for Passivating High Voltage Cathodes  

NLE Websites -- All DOE Office Websites (Extended Search)

batteries with the goal of significantly increasing battery energy density. Conventional Li-ion battery electrolyte systems are quite unstable at these high potentials, leading to...

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360{degree}/n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load. 7 figs.

Shimer, D.W.; Lange, A.C.

1997-03-11T23:59:59.000Z

82

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1997-01-01T23:59:59.000Z

83

Experiment Hazard Class 13.0 - High Voltage  

NLE Websites -- All DOE Office Websites (Extended Search)

3.0 - High Voltage 3.0 - High Voltage Applicability This hazard classification applies to all experiments involving the use of High Voltage Equipment. Other hazard classifications and their associated hazard controls may also apply to experiments in this hazard class. The inspection of electric equipment is covered under the APS Policy For User Electric Equipment Inspections. NOTE: Unless required Argonne training has been completed, users are not authorized to perform electrical work. Experiment Category All Hazard Class 13 experiments are categorized as medium risk experiments. Experiment Hazard Control Verification Statements Engineered Controls - Determined by review and results of a DEEI inspection of the equipment. Procedural Controls - Determined by review and results of a DEEI

84

High voltage stability performance of a gamma ray detection device  

SciTech Connect

An industrial grade digital radiation survey meter device is currently being developed at Malaysian Nuclear Agency. This device used a cylindrical type Geiger Mueller (GM) which acts as a detector. GM detector operates at relatively high direct current voltages depend on the type of GM tube. This thin/thick walled cylindrical type of GM tube operates at 450-650 volts range. Proper value and stability performance of high voltage are important parameters to ensure that this device give a reliable radiation dose measurement. This paper will present an assessment of the stability and performance of the high voltage supply for radiation detector. The assessment is performed using System Identification tools box in MATLAB and mathematical statistics.

Abdullah, Nor Arymaswati; Lombigit, Lojius; Rahman, Nur Aira Abd [Technical Support Division, Malaysian Nuclear Agency, 43000 Kajang, Selangor (Malaysia)

2014-02-12T23:59:59.000Z

85

A Radiofrequency High-Voltage Generator  

Science Journals Connector (OSTI)

A large radio oscillator with unrectified alternating anode power-supply sends high-frequency power into a 50 meter wave-length antenna which is coiled up without insulation, and enclosed in a metal vacuum tank. Over 800,000 volts is generated inside of the tank exactly where it is to be used for x-rays or for accelerating ions. There is no insulation to become punctured. Single tuned-circuit resonance transformers are superior to coupled tuned-circuit Tesla coils. Resonance transformers, oscillator circuits, power tubes, power supply and coil construction are described. X-ray production, and ion acceleration are outlined.

David H. Sloan

1935-01-01T23:59:59.000Z

86

Cable Diagnostic Focused Initiative  

SciTech Connect

This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online knowledge based system (KBS) that helps utilities select the most effective diagnostic technologies for a given cable circuit and circuit conditions.

Hartlein, R.A.; Hampton, R.N.

2010-12-30T23:59:59.000Z

87

Self-Excited ac High Voltage Generation Using Water Droplets  

Science Journals Connector (OSTI)

By letting water drops fall through rings into cans high voltage can be spontaneously generated with no external electrical excitation. Previous work concerning this type of electric influence machine for dc and three-phase ac high voltage generation is extended to include multiphase multifrequency operation by considering N streams and N cans. A distributed equivalent circuit representation is used to calculate the natural frequencies of the system where it is found that many overstable modes are present. Experimental observations with up to five cans are presented. This device can serve as a model for phenomena concerned with atmospheric electricity.

Markus Zahn

1973-01-01T23:59:59.000Z

88

Summaries of Addresses of Presidents of Sections: High-Voltage Insulation  

Science Journals Connector (OSTI)

... subject of his presidential address to Section A (Mathematics and Physics) *'High-voltage Insulation".

1963-08-31T23:59:59.000Z

89

Current isolating epitaxial buffer layers for high voltage photodiode array  

DOE Patents (OSTI)

An array of photodiodes in series on a common semi-insulating substrate has a non-conductive buffer layer between the photodiodes and the semi-insulating substrate. The buffer layer reduces current injection leakage between the photodiodes of the array and allows optical energy to be converted to high voltage electrical energy.

Morse, Jeffrey D. (Martinez, CA); Cooper, Gregory A. (Pleasant Hill, CA)

2002-01-01T23:59:59.000Z

90

Field Optimization of Three Dimensional High Voltage C. Trinitis  

E-Print Network (OSTI)

Field Optimization of Three Dimensional High Voltage Equipment C. Trinitis Lehrstuhl f The goal of finding an optimal electric field strength distribution for arbitrary three diĀ­ mensionalĀ­ cal optimization algorithm. The package obĀ­ tained from these three components is then able

Stamatakis, Alexandros

91

High voltage gas insulated transmission line with continuous particle trapping  

DOE Patents (OSTI)

This invention provides a novel high voltage gas insulated transmission line utilizing insulating supports spaced at intervals with snap-in means for supporting a continuous trapping apparatus and said trapping apparatus having perforations and cutouts to facilitate trapping of contaminating particles and system flexibility.

Cookson, Alan H. (Pittsburgh, PA); Dale, Steinar J. (Monroeville, PA)

1983-01-01T23:59:59.000Z

92

High Voltage DC Transmission 2 1.0 Introduction  

E-Print Network (OSTI)

1 High Voltage DC Transmission 2 1.0 Introduction Interconnecting HVDC within an AC system requires on use of switching devices collectively referred to in the HVDC community as valves. Valves may be non. Fig. 1 There have been three types of devices for implementing HVDC converter circuits: mercury

McCalley, James D.

93

Triaxial HTS Cable for the AEP Bixby Project  

SciTech Connect

Ultera has installed a single 200-meter long high temperature superconducting (HTS) 3-phase triaxial design cable at the American Electric Power (AEP) Bixby substation in Columbus, Ohio. The cable connects a 132/13.8 kV transformer to the distribution switchgear serving seven outgoing circuits. It was designed to carry 3000 Arms. Testing of 3- to 5-meter length prototype cables, including a 5-meter prototype with full scale terminations tested at ORNL was conducted prior to the manufacture and installation of the AEP triaxial cable. These prototypes were used to demonstrate the crucial operating conditions including steady state operation at the 3000 Arms design current, high voltage operation, high voltage withstand and 110 kV impulse, and overcurrent fault capability. A summary of the results from the thermal analysis and testing conducted by Ultera and ORNL will be presented. Some analysis of the cable thermal-hydraulic response based on the testing that were used to determine some of the cable cryogenic system requirements are also presented.

Demko, Jonathan A [ORNL; Gouge, Michael J [ORNL; Lindsay, David T [ORNL; Roden, Mark L [ORNL; Tolbert, Jerry Carlton [ORNL

2007-01-01T23:59:59.000Z

94

British Standard Specification for Cable Insulation  

Science Journals Connector (OSTI)

... different types of cables and cords ; and the third, with tests for thickness of insulation and sheath, voltage, ... and sheath, voltage, insulation resistance, spark testing, tinning and armouring. The numerous tables with which the specification ...

1947-02-22T23:59:59.000Z

95

High voltage dc--dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.

Shimer, D.W.; Lange, A.C.

1995-05-23T23:59:59.000Z

96

High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1995-01-01T23:59:59.000Z

97

Advanced Gate Drive for the SNS High Voltage Converter Modulator  

SciTech Connect

SLAC National Accelerator Laboratory is developing a next generation H-bridge switch plate [1], a critical component of the SNS High Voltage Converter Modulator [2]. As part of that effort, a new IGBT gate driver has been developed. The drivers are an integral part of the switch plate, which are essential to ensuring fault-tolerant, high-performance operation of the modulator. The redesigned driver improves upon the existing gate drive in several ways. The new gate driver has improved fault detection and suppression capabilities; suppression of shoot-through and over-voltage conditions, monitoring of dI/dt and Vce(sat) for fast over-current detection and suppression, and redundant power isolation are some of the added features. In addition, triggering insertion delay is reduced by a factor of four compared to the existing driver. This paper details the design and performance of the new IGBT gate driver. A simplified schematic and description of the construction are included. The operation of the fast over-current detection circuits, active IGBT over-voltage protection circuit, shoot-through prevention circuitry, and control power isolation breakdown detection circuit are discussed.

Nguyen, M.N.; Burkhart, C.; Kemp, M.A.; /SLAC; Anderson, D.E.; /Oak Ridge

2009-05-07T23:59:59.000Z

98

Fiber optic current monitor for high-voltage applications  

DOE Patents (OSTI)

A current monitor which derives its power from the conductor being measured for bidirectionally measuring the magnitude of current (from DC to above 50 khz) flowing through a conductor across which a relatively high level DC voltage is applied, includes a pair of identical transmitter modules connected in opposite polarity to one another in series with the conductor being monitored, for producing from one module a first light signal having an intensity directly proportional to the magnitude of current flowing in one direction through the conductor during one period of time, and from the other module a second light signal having an intensity directly proportional to the magnitude of current flowing in the opposite direction through the conductor during another period of time, and a receiver located in a safe area remote from the high voltage area for receiving the first and second light signals, and converting the same to first and second voltage signals having levels indicative of the magnitude of current being measured at a given time.

Renda, George F. (Plainsboro, NJ)

1992-01-01T23:59:59.000Z

99

Operation experiences with a 30 kV/100 MVA high temperature superconducting cable system  

Science Journals Connector (OSTI)

A superconducting cable based on Bi-2223 tape technology has been developed, installed and operated in the public network of Copenhagen Energy in a two-year period between May 2001 and May 2003. This paper gives a brief overview of the system and analyses some of the operation experiences. The aim of this demonstration project is to gain experience with HTS cables under realistic conditions in a live distribution network. Approximately 50?000 utility customers have their electric power supplied through the HTS cable. The cable system has delivered 226 GW h of energy and reached a maximum operating current of 1157 A. The operation experiences include over-currents of 6 kA due to faults on peripheral lines, commissioning, servicing and failure responses on the cooling system, continuous 24 h, 7 day per week monitoring and performance of the alarm system. The implications of these experiences for the future applications of HTS cable systems are analysed.

Ole Tųnnesen; Manfred Däumling; Kim H Jensen; Svend Kvorning; Sųren K Olsen; Chresten Tręholt; Erling Veje; Dag Willén; Jacob Ųstergaard

2004-01-01T23:59:59.000Z

100

Project Fact Sheet Long Island HTS Power Cable Superconducting  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Long Long Island HTS Power Cable Superconducting Power Equipment www.oe.energy.gov Phone: 202-586-1411 Office of Electricity Delivery and Energy Reliability, OE-1 U.S. Department of Energy - 1000 Independence Avenue, SW - Washington, DC 20585 Plugging America Into the Future of Power What is the status of the Project? The cable was energized April 22, 2008 and serves the equivalent of 300,000 homes. It is the first HTS power cable to operate at transmission voltage in the grid. LIPA plans to retain the superconductor as a permanent part of it's grid. This project involves the demonstration of a high- temperature superconducting (HTS) power cable in the Long Island Power grid, spanning nearly half a mile and serving as a permanent link in the Long Island Power

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

High Power, High Voltage FETs in Linear Applications: A User's Perspective  

SciTech Connect

The specifications of the current crop of highpower, high-voltage field-effect transistors (FETs) can lure a designer into employing them in high-voltage DC equipment. Devices with extremely low on-resistance and very high power ratings are available from several manufacturers. However, our experience shows that high-voltage, linear operation of these devices at near-continuous duty can present difficult reliability challenges at stress levels well-below their published specifications. This paper chronicles the design evolution of a 600 volt, 8 ampere shunt regulator for use with megawatt-class radio transmitters, and presents a final design that has met its reliability criteria.

N. Greenough, E. Fredd, S. DePasquale

2009-09-21T23:59:59.000Z

102

Distribution System Voltage Performance Analysis for High-Penetration Photovoltaics  

SciTech Connect

This report examines the performance of commonly used distribution voltage regulation methods under reverse power flow.

Liu, E.; Bebic, J.

2008-02-01T23:59:59.000Z

103

A Theoretical Analysis of the Use of Submarine Cables as Electromagnetic Oceanographic Flowmeters  

Science Journals Connector (OSTI)

...Theoretical Analysis of the Use of Submarine Cables as Electromagnetic Oceanographic Flowmeters...voltage measured across the ends of a submarine cable as a measure of the sea flow across the cable section. In part I a method of calculating...

1976-01-01T23:59:59.000Z

104

High-voltage R-F feedthrough bushing  

DOE Patents (OSTI)

Described is a multi-element, high voltage radio frequency bushing for transmitting rf energy to an antenna located in a vacuum container. The bushing includes a center conductor of complex geometrical shape, an outer coaxial shield conductor, and a thin-walled hollow truncated cone insulator disposed between central and outer conductors. The shape of the center conductor, which includes a reverse curvature portion formed of a radially inwardly directed shoulder and a convex portion, controls the uniformity of the axial surface gradient on the insulator cone. The outer shield has a first substantially cylindrical portion and a second radially inwardly extending truncated cone portion.

Grotz, G.F.

1982-09-03T23:59:59.000Z

105

Self-monitoring high voltage transmission line suspension insulator  

DOE Patents (OSTI)

A high voltage transmission line suspension insulator (18 or 22) which monitors its own dielectric integrity. A dielectric rod (10) has one larger diameter end fitting attachable to a transmission line and another larger diameter end fitting attachable to a support tower. The rod is enclosed in a dielectric tube (14) which is hermetically sealed to the rod's end fittings such that a liquidtight space (20) is formed between the rod and the tube. A pressurized dielectric liquid is placed within that space. A discoloring dye placed within this space is used to detect the loss of the pressurized liquid.

Stemler, Gary E. (Vancouver, WA); Scott, Donald N. (Vancouver, WA)

1981-01-01T23:59:59.000Z

106

An Approximate Dynamic Programming Algorithm for the Allocation of High-Voltage Transformer Spares in the  

E-Print Network (OSTI)

An Approximate Dynamic Programming Algorithm for the Allocation of High-Voltage Transformer Spares high-voltage transformer spares throughout the electric grid to mitigate the risk of random transformer-voltage transformers are an integral part of the electric transmission system. A catas- trophic transformer failure

Powell, Warren B.

107

Seismic vulnerability assessment of a high voltage disconnect switch  

Science Journals Connector (OSTI)

Abstract This paper deals with the seismic vulnerability of high voltage equipment typically installed in electric substations. In particular, the seismic response of a 380 kV vertical disconnect switch has been investigated based on the results of an experimental campaign carried out at Roma Tre University. According to a series of non-linear analyses, the influence of the most significant parameters on the seismic behavior of this apparatus has been analyzed and the corresponding fragility curves have been evaluated by using the Effective Fragility Analysis method. The results showed a limited vulnerability of the disconnect switch, whose most critical parts are the bottom joint of the ceramic support column and the steel column base.

Fabrizio Paolacci; Renato Giannini; Silvia Alessandri; Gianmarco De Felice

2014-01-01T23:59:59.000Z

108

Voltage spike detection in high field superconducting accelerator magnets  

SciTech Connect

A measurement system for the detection of small magnetic flux changes in superconducting magnets, which are due to either mechanical motion of the conductor or flux jump, has been developed at Fermilab. These flux changes are detected as small amplitude, short duration voltage spikes, which are {approx}15mV in magnitude and lasts for {approx}30 {micro}sec. The detection system combines an analog circuit for the signal conditioning of two coil segments and a fast data acquisition system for digitizing the results, performing threshold detection, and storing the resultant data. The design of the spike detection system along with the modeling results and noise analysis will be presented. Data from tests of high field Nb{sub 3}Sn magnets at currents up to {approx}20KA will also be shown.

Orris, D.F.; Carcagno, R.; Feher, S.; Makulski, A.; Pischalnikov, Y.M.; /Fermilab

2004-12-01T23:59:59.000Z

109

Monolithic high voltage nonlinear transmission line fabrication process  

DOE Patents (OSTI)

A process for fabricating sequential inductors and varistor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varistor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process. 6 figs.

Cooper, G.A.

1994-10-04T23:59:59.000Z

110

High-speed, sub-pull-in voltage MEMS switching.  

SciTech Connect

We have proposed and demonstrated MEMS switching devices that take advantage of the dynamic behavior of the MEMS devices to provide lower voltage actuation and higher switching speeds. We have explored the theory behind these switching techniques and have demonstrated these techniques in a range of devices including MEMS micromirror devices and in-plane parallel plate MEMS switches. In both devices we have demonstrated switching speeds under one microsecond which has essentially been a firm limit in MEMS switching. We also developed low-loss silicon waveguide technology and the ability to incorporate high-permittivity dielectric materials with MEMS. The successful development of these technologies have generated a number of new projects and have increased both the MEMS switching and optics capabilities of Sandia National Laboratories.

Spahn, Olga Blum; Brewer, Steven; Olsson, Roy H.; Bogart, Gregory R.; Luck, David L.; Watts, Michael R.; Shaw, Michael J.; Nielson, Gregory N.; Resnick, Paul James; Tigges, Christopher P.; Grossetete, Grant David

2008-01-01T23:59:59.000Z

111

Monolithic high voltage nonlinear transmission line fabrication process  

DOE Patents (OSTI)

A process for fabricating sequential inductors and varactor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varactor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process.

Cooper, Gregory A. (346 Primrose Dr., Pleasant Hill, CA 94523)

1994-01-01T23:59:59.000Z

112

Summary of multiterminal high-voltage direct current transmission technology  

SciTech Connect

This report summarizes the present state of multiterminal (MT) high-voltage direct current (HVDC) power transmission. The purpose is to reassess the need for HVDC circuit breakers and to identify needed research for MT HVDC. The fundamentals of this technology are presented, and previous research and development is reviewed. Although no MT HVDC systems have yet been built, many concepts have been proposed. Some require a dc breaker, and others do not. Both options have advantages and disadvantages for various applications, so the selection will depend on the proposed application. Research is needed to define operating characteristics of various MT HVDC systems. In some applications, dc breakers will be useful, so research into HVDC interruption should continue. Also, dc fault detection and control algorithms for MT systems should be studied.

Biggs, R.B.; Jewell, W.T.

1984-05-01T23:59:59.000Z

113

High-voltage supply for neutron tubes in well-logging applications  

DOE Patents (OSTI)

A high voltage supply is provided for a neutron tube used in well logging. The biased pulse supply of the invention combines DC and full pulse techniques and produces a target voltage comprising a substantial negative DC bias component on which is superimposed a pulse whose negative peak provides the desired negative voltage level for the neutron tube. The target voltage is preferably generated using voltage doubling techniques and employing a voltage source which generates bipolar pulse pairs having an amplitude corresponding to the DC bias level.

Humphreys, D.R.

1982-09-15T23:59:59.000Z

114

Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power Filter Applications  

E-Print Network (OSTI)

Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power voltage-source inverters connected in series (known as cascaded hybrid asymmetric multilevel inverter voltage application due to semiconductor constraint. In order to achieve higher power level, hybrid

Catholic University of Chile (Universidad CatĆ³lica de Chile)

115

Radio-Frequency Interference (RFI) From Extra-High-Voltage (EHV) Transmission Lines  

E-Print Network (OSTI)

discharges are a design issue. Extra-high-voltage (EHV) transmission lines have operating voltages of 345 kV building a 345-kV transmission line from Red Hill, NM to Deming, NM which would run east along US60 to its with respect to radio noise: (1) lines with voltages below 70 kV and (2) lines with voltages above 110 kV

Ellingson, Steven W.

116

Control of Analyte Electrolysis in Electrospray Ionization Mass Spectrometry Using Repetitively Pulsed High Voltage  

SciTech Connect

Analyte electrolysis using a repetitively pulsed high voltage ion source was investigated and compared to that using a regular, continuously operating direct current high voltage ion source in electrospray ionization mass spectrometry. The extent of analyte electrolysis was explored as a function of the length and frequency of the high voltage pulse using the model compound reserpine in positive ion mode. Using +5 kV as the maximum high voltage amplitude, reserpine was oxidized to its 2, 4, 6 and 8-electron oxidation products when direct current high voltage was employed. In contrast, when using a pulsed high voltage, oxidation of reserpine was eliminated by employing the appropriate high voltage pulse length and frequency. This effect was caused by inefficient mass transport of the analyte to the electrode surface during the duration of the high voltage pulse and the subsequent relaxation of the emitter electrode/ electrolyte interface during the time period when the high voltage was turned off. This mode of ESI source operation allows for analyte electrolysis to be quickly and simply switched on or off electronically via a change in voltage pulse variables.

Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

2011-01-01T23:59:59.000Z

117

Superconductor cable  

DOE Patents (OSTI)

A superconductor cable includes a superconductive cable core (1) and a cryostat (2) enclosing the same. The cable core (1) has a superconductive conductor (3), an insulation (4) surrounding the same and a shielding (5) surrounding the insulation (4). A layer (3b) of a dielectric or semiconducting material is applied to a central element (3a) formed from a normally conducting material as a strand or tube and a layer (3c) of at least one wire or strip of superconductive material is placed helically on top. The central element (3a) and the layer (3c) are connected to each other in an electrically conducting manner at the ends of the cable core (1).

Allais, Arnaud (Hannover, DE); Schmidt, Frank (Langenhagen, DE

2009-12-15T23:59:59.000Z

118

High voltage power supply with modular series resonant inverters  

DOE Patents (OSTI)

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360.degree./n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit.

Dreifuerst, Gary R. (Livermore, CA); Merritt, Bernard T. (Livermore, CA)

1995-01-01T23:59:59.000Z

119

High voltage power supply with modular series resonant inverters  

DOE Patents (OSTI)

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360{degree}/n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit. 11 figs.

Dreifuerst, G.R.; Merritt, B.T.

1995-07-18T23:59:59.000Z

120

Object Oriented Safety Analysis of an Extra High Voltage Substation Bay  

Science Journals Connector (OSTI)

Experiences of application of the object oriented approach to safety analysis of an extra high voltage substation bay are presented. As the first step...

Bartosz Nowicki; Janusz Górski

1998-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Theory and practice of dynamic voltage/frequency scaling in the high performance computing environment.  

E-Print Network (OSTI)

?? This dissertation provides a comprehensive overview of the theory and practice of Dynamic Voltage/Frequency Scaling (DVFS) in the High Performance Computing (HPC) environment. We… (more)

Rountree, Barry Louis

2010-01-01T23:59:59.000Z

122

Automotive high-voltage electrical system with integrated safeguard  

Science Journals Connector (OSTI)

For several years the use of higher system voltages has been a topic in the automotive industry. Whether for hybrid or conventional vehicles, safeguards are required which protect both the vehicle...

Thomas Flottmann

2007-03-01T23:59:59.000Z

123

Radio-frequency powered glow discharge device and method with high voltage interface  

DOE Patents (OSTI)

A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components. 11 figures.

Duckworth, D.C.; Marcus, R.K.; Donohue, D.L.; Lewis, T.A.

1994-06-28T23:59:59.000Z

124

Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions  

E-Print Network (OSTI)

Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 19-1 High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 1. DC Properties of Modern Filled Epoxy Insulation Academic and Research Staff Dr. Chathan Cooke Sponsor

125

Evaluation of Insulation Systems for the Optimal Design of High Voltage Pulse Transformers  

E-Print Network (OSTI)

This paper presents a study for the design of the insulation systems of high voltage pulse transformer based on experimental tests and numerical simulations. Data of high voltage tests on solid and liquid insulation materials are presented and discussed. The understanding of each part of the insulation is supported by electrostatic fields simulations.

Sylvain, Candolfi; Davide, Aguglia; Philippe, Viarouge; Jürgen, Biela; Jerome, Cros

2015-01-01T23:59:59.000Z

126

High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report | Open  

Open Energy Info (EERE)

High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report Jump to: navigation, search Tool Summary LAUNCH TOOL Name: High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report Focus Area: Crosscutting Topics: Policy Impacts Website: www.netl.doe.gov/smartgrid/referenceshelf/reports/HV-BPL_Final_Report. Equivalent URI: cleanenergysolutions.org/content/high-voltage-broadband-over-powerline Language: English Policies: "Deployment Programs,Financial Incentives" is not in the list of possible values (Deployment Programs, Financial Incentives, Regulations) for this property. DeploymentPrograms: Technical Assistance This reports details findings from a pilot High Voltage Broadband over Power Line (HV-BPL) program, an effort to develop a disruptive technology

127

Design of the Wireless Temperature Measurement Alarming System in the High-Voltage Transformer Substation  

Science Journals Connector (OSTI)

Due to electric power overload and equipment aging, fire and explosion occur at transmission circuitry joints in high-voltage transformer substation caused by high temperatures accumulated at these...

Qiang Gao; Hongli Wang; Huaxiang Wang

2008-01-01T23:59:59.000Z

128

The high voltage problem in the saturated core HTS fault current limiter  

Science Journals Connector (OSTI)

A small model of a one-phase saturated core HTS fault current limiter was developed. It consists of an iron core, an AC coil and a DC HTS coil. The HTS coil comprised six 126 turns double-pancakes (ID 70 mm), wound after heat treatment from Bi-2223 multifilamentary tape in Ag matrix. A fault simulation circuit was set up to characterize the dynamic properties of the model limiter. The voltages and currents of the AC coil and the DC HTS coil were measured through a computer-based data acquisition system. The tests have shown that the limiter has a fast response and the first current peak can be easily limited, but a high voltage will be induced on the DC HTS coil side during the fault state. This high voltage can badly affect the DC current equipment on the DC HTS coil side. The origin and value of the high voltage can be explained using a transformer model. For a limiter with n1 turns AC coil and n2 turns DC coil, the largest induced voltage will be roughly close to (n2/n1)U, where U is the rated voltage of the limiter. To commercialize this kind of limiter, the high voltage problem must be solved. Some different designs were introduced to lower the induced voltage.

Y.F. He; J.H. Li; X.H. Zong; J. Sun; Y.N. Wang; C.L. Wu; J.X. Wang

2003-01-01T23:59:59.000Z

129

Public Opinions of Building Additional High-Voltage Electric Power Lines  

E-Print Network (OSTI)

to build new power lines. Residents living in counties with planned routes for new transmission linesPublic Opinions of Building Additional High-Voltage Electric Power Lines A Report to the National-Voltage Electric Power Lines: A Report to the National Science Foundation and the Electric Power Research Center

Tesfatsion, Leigh

130

Dielectric-wall linear accelerator with a high voltage fast rise time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators  

DOE Patents (OSTI)

A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface. 12 figs.

Caporaso, G.J.; Sampayan, S.E.; Kirbie, H.C.

1998-10-13T23:59:59.000Z

131

Numerical Analysis of Heat Transfer and Fluid Characteristics of Flowing Liquid Nitrogen in HTS Cable  

Science Journals Connector (OSTI)

Abstract High-temperature superconducting (HTS) cable has heat intrusion from the termination including joule heat generation at the terminal joint and from the room temperature cable through the Cu current lead. According to the length of the HTS cable, this heat loss may become a considerable amount which cannot be ignored in the HTS cable system. In this study, referring to a high-voltage cable (HV cable) which was developed in M-PACC project, the effect of heat transfer at the interface between the terminal joint and LN2 in the terminal vessel (ho) on the temperature of the HTS cable were calculated and evaluated. The condition of flow in the terminal vessel was assumed to be natural convection, forced flow or static condition for evaluating this effect with various heat transfer condition. As a result, in the case of the natural convection, most of heats flow into the LN2 in the terminal vessel where the volumetric flow of the LN2 is large since ho becomes high. Accordingly, the temperature rise of the LN2 in the inner pipe of Cu former and the terminal vessel can be restricted. However, in the cases of the forced flow and the static condition, most of heats flow into the LN2 in the inner pipe where the volumetric flow of the LN2 is small since ho becomes small. Accordingly, the temperature rise of the LN2 in the inner pipe becomes high. This temperature rise of the LN2 in the inner pipe makes the temperature of the HTS conductor large resulting in remarkable increase of AC losses. Consequently, on the HV cable design, for restriction of the AC loss increase, it is expected that designing the HTS cable termination such as extending outer surface of the terminal joint for increasing of the heat inflow from the terminal joint to the LN2 in the vessel is effective.

O. Maruyama; T. Ohkuma; T. Izumi; Y. Shiohara

2014-01-01T23:59:59.000Z

132

Superconducting Cable  

DOE Patents (OSTI)

In order to provide a flexible oxide superconducting cable which is reduced in AC loss, tape-shaped superconducting wires covered with a stabilizing metal are wound on a flexible former. The superconducting wires are preferably laid on the former at a bending strain of not more than 0.2%. In laying on the former, a number of tape-shaped superconducting wires are laid on a core member in a side-by-side manner, to form a first layer. A prescribed number of tape-shaped superconducting wires are laid on top of the first layer in a side-by-side manner, to form a second layer. The former may be made of a metal, plastic, reinforced plastic, polymer, or a composite and provides flexibility to the superconducting wires and the cable formed therewith.

Hughey, Raburn L. (Franklin, GA); Sinha, Uday K. (Carrollton, GA); Reece, David S. (Carrollton, GA); Muller, Albert C. (Eidson, TN)

2005-07-22T23:59:59.000Z

133

Superconducting Cable  

DOE Patents (OSTI)

In order to provide a flexible oxide superconducting cable which is reduced in AC loss, tape-shaped superconducting wires covered with a stabilizing metal are wound on a flexible former. The superconducting wires are preferably laid on the former at a bending strain of not more than 0.2%. In laying on the former, a number of tape-shaped superconducting wires are laid on a core member in a side-by-side manner, to form a first layer. A prescribed number of tape-shaped superconducting wires are laid on top of the first layer in a side-by-side manner, to form a second layer. The former may be made of a metal, plastic, reinforced plastic, polymer, or a composite and provides flexibility to the superconducting wires and the cable formed therewith.

Hughey, Raburn L. (Franklin, GA); Sinha, Uday K. (Carrollton, GA); Reece, David S. (Carrollton, GA); Muller, Albert C. (Eidson, TN)

2005-03-08T23:59:59.000Z

134

Light-weight DC to very high voltage DC converter  

DOE Patents (OSTI)

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current.

Druce, Robert L. (Union City, CA); Kirbie, Hugh C. (Dublin, CA); Newton, Mark A. (Livermore, CA)

1998-01-01T23:59:59.000Z

135

Light-weight DC to very high voltage DC converter  

DOE Patents (OSTI)

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current. 1 fig.

Druce, R.L.; Kirbie, H.C.; Newton, M.A.

1998-06-30T23:59:59.000Z

136

Princeton Power Systems (TRL 5 6 Component)- Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage  

Energy.gov (U.S. Department of Energy (DOE))

Princeton Power Systems (TRL 5 6 Component) - Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage

137

Generalized charge simulation method for the calculation of the electric field in high voltage substations  

Science Journals Connector (OSTI)

This paper deals with the calculation of the electric field strength in high voltage (HV) substations comprising complex geometrical structures. Generalized charge simulation ... is to examine the influence of to...

Aleksandar Rankovi?; Milan S. Savi?

2010-07-01T23:59:59.000Z

138

Vehicle Technologies Office Merit Review 2014: High-Voltage Solid Polymer Batteries for Electric Drive Vehicles  

Energy.gov (U.S. Department of Energy (DOE))

Presentation given by Seeo, Inc. at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about high-voltage solid polymer...

139

Optical High Voltage Sensor with Oil- and Gas-free Insulation  

Science Journals Connector (OSTI)

We present an electro-optic high voltage sensor with novel oil- and gas-free insulation based on capacitive electric field steering. The sensor's accuracy is within ±0.2% in a...

Marchese, Sergio V; Wildermuth, Stephan; Steiger, Olivier; Pascal, Joris; Bohnert, Klaus; Eriksson, Göran; Czyzewski, Jan

140

Current mode integrators and their applications in low-voltage high frequency CMOS signal processing  

E-Print Network (OSTI)

Low voltage CMOS fully differential integrators for high frequency continuous-time filters using current-mode techniques are presented.. Current mode techniques are employed to avoid the use of the floating differential pair, in order to achieve...

Smith, Sterling Lane

2012-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Low Cost SiOx-Graphite and High Voltage Spinel Cathode | Department...  

Office of Environmental Management (EM)

Cathode Low Cost SiOx-Graphite and High Voltage Spinel Cathode 2011 DOE Hydrogen and Fuel Cells Program, and Vehicle Technologies Program Annual Merit Review and Peer Evaluation...

142

High-voltage pulsed discharge in an electron source with a plasma cathode  

Science Journals Connector (OSTI)

The nature of and mechanism for producing a high-voltage discharge in an electron source with a plasma cathode are investigated. The possibility of generating pulsed electron currents with an amplitude of 103–104

S. P. Bugaev; F. Ya. Zagulov

1973-10-01T23:59:59.000Z

143

A new concept for test equipment for testing large HV and UHV cables on-site  

Science Journals Connector (OSTI)

The number of projects involving long and extra long HV and UHV AC cables as well as HVDC cable...Cao et al., 2008; Kabouris et al., 2006). At the same time, operating voltage levels are increasing, accentuating ...

P. Mohaupt; A. Bergman

2010-12-01T23:59:59.000Z

144

Cermet insert high voltage holdoff improvement for ceramic/metal vacuum devices  

DOE Patents (OSTI)

An improved metal-to-ceramic seal is provided wherein the ceramic body of the seal contains an integral region of cermet material in electrical contact with the metallic member, e.g., an electrode, of the seal. The seal is useful in high voltage vacuum devices, e.g., vacuum switches, and increases the high-voltage holdoff capabilities of such devices. A method of fabricating such seals is also provided.

Ierna, W.F.

1986-03-11T23:59:59.000Z

145

Voltage-dependent calcium channels and currents in native neurons and other cells have been divided into high voltage  

E-Print Network (OSTI)

Voltage-dependent calcium channels and currents in native neurons and other cells have been divided than one subtype of channel. A new subfamily of voltage-dependent calcium channel Ɣ1 subunit genes. 1999), having four domains, each with a voltage sensor and a pore-forming P loop. However

Dolphin, Annette C.

146

Membrane-Transistor Cable  

Science Journals Connector (OSTI)

Membrane-Transistor Cable ... The system is the basis for a development of bioelectronic transducers and for the study of nonlinear phenomena in membrane cables. ...

Marion Rentschler; Peter Fromherz

1998-01-20T23:59:59.000Z

147

Connecting Renewables Directly to the Grid: Resilient Multi-Terminal HVDC Networks with High-Voltage High-Frequency Electronics  

SciTech Connect

GENI Project: GE is developing electricity transmission hardware that could connect distributed renewable energy sources, like wind farms, directly to the grid—eliminating the need to feed the energy generated through intermediate power conversion stations before they enter the grid. GE is using the advanced semiconductor material silicon carbide (SiC) to conduct electricity through its transmission hardware because SiC can operate at higher voltage levels than semiconductors made out of other materials. This high-voltage capability is important because electricity must be converted to high-voltage levels before it can be sent along the grid’s network of transmission lines. Power companies do this because less electricity is lost along the lines when the voltage is high.

None

2012-01-23T23:59:59.000Z

148

The design, construction, and operation of long-distance high-voltage electricity transmission technologies.  

SciTech Connect

This report focuses on transmission lines, which operate at voltages of 115 kV and higher. Currently, the highest voltage lines comprising the North American power grid are at 765 kV. The grid is the network of transmission lines that interconnect most large power plants on the North American continent. One transmission line at this high voltage was built near Chicago as part of the interconnection for three large nuclear power plants southwest of the city. Lines at this voltage also serve markets in New York and New England, also very high demand regions. The large power transfers along the West Coast are generally at 230 or 500 kV. Just as there are practical limits to centralization of power production, there are practical limits to increasing line voltage. As voltage increases, the height of the supporting towers, the size of the insulators, the distance between conductors on a tower, and even the width of the right-of-way (ROW) required increase. These design features safely isolate the electric power, which has an increasing tendency to arc to ground as the voltage (or electrical potential) increases. In addition, very high voltages (345 kV and above) are subject to corona losses. These losses are a result of ionization of the atmosphere, and can amount to several megawatts of wasted power. Furthermore, they are a local nuisance to radio transmission and can produce a noticeable hum. Centralized power production has advantages of economies of scale and special resource availability (for instance, hydro resources), but centralized power requires long-distance transfers of power both to reach customers and to provide interconnections for reliability. Long distances are most economically served at high voltages, which require large-scale equipment and impose a substantial footprint on the corridors through which power passes. The most visible components of the transmission system are the conductors that provide paths for the power and the towers that keep these conductors at a safe distance from each other and from the ground and the natural and built environment. Common elements that are generally less visible (or at least more easily overlooked) include the maintained ROW along the path of the towers, access roads needed for maintenance, and staging areas used for initial construction that may be restored after construction is complete. Also visible but less common elements along the corridor may include switching stations or substations, where lines of similar or different voltages meet to transfer power.

Molburg, J. C.; Kavicky, J. A.; Picel, K. C.

2008-03-03T23:59:59.000Z

149

Prediction of insulation degradation of distribution power cables based on chemical analysis and electrical measurements.  

E-Print Network (OSTI)

??This thesis deals with the prediction of medium voltage cable insulation condition. Different kinds of electrical measurements and chemical analyses are tested to find out… (more)

Hyvönen, Petri

2008-01-01T23:59:59.000Z

150

A high-gain adaptive observer for detecting Li-ion battery terminal voltage collapse  

Science Journals Connector (OSTI)

We use a high-gain adaptive observer and a trend filtering algorithm to detect early stages that lead to terminal voltage collapses in Li-ion batteries. This approach allows accurate detection without having sophisticated battery models. Theoretical ... Keywords: Adaptive filters, Adaptive systems, Detection algorithms, High-gain, Trend

Shayok Mukhopadhyay, Fumin Zhang

2014-03-01T23:59:59.000Z

151

Dual design resistor for high voltage conditioning and transmission lines  

DOE Patents (OSTI)

A dual resistor for eliminating the requirement for two different value resistors. The dual resistor includes a conditioning resistor at a high resistance value and a run resistor at a low resistance value. The run resistor can travel inside the conditioning resistor. The run resistor is capable of being advanced by a drive assembly until an electrical path is completed through the run resistor thereby shorting out the conditioning resistor and allowing the lower resistance run resistor to take over as the current carrier.

Siggins, Timothy Lynn (Newport News, VA); Murray, Charles W. (Hayes, VA); Walker, Richard L. (Norfolk, VA)

2007-01-23T23:59:59.000Z

152

Optimizing performance per watt on GPUs in High Performance Computing: temperature, frequency and voltage effects  

E-Print Network (OSTI)

The magnitude of the real-time digital signal processing challenge attached to large radio astronomical antenna arrays motivates use of high performance computing (HPC) systems. The need for high power efficiency (performance per watt) at remote observatory sites parallels that in HPC broadly, where efficiency is an emerging critical metric. We investigate how the performance per watt of graphics processing units (GPUs) is affected by temperature, core clock frequency and voltage. Our results highlight how the underlying physical processes that govern transistor operation affect power efficiency. In particular, we show experimentally that GPU power consumption grows non-linearly with both temperature and supply voltage, as predicted by physical transistor models. We show lowering GPU supply voltage and increasing clock frequency while maintaining a low die temperature increases the power efficiency of an NVIDIA K20 GPU by up to 37-48% over default settings when running xGPU, a compute-bound code used in radio...

Price, D C; Barsdell, B R; Babich, R; Greenhill, L J

2014-01-01T23:59:59.000Z

153

Investigation of a Rutherford cable using coated conductor Roebel cables as strands  

Science Journals Connector (OSTI)

Coated conductor applications such as fusion magnets, particle accelerator magnets and generator windings require high current-carrying capabilities. This requirement can be fulfilled by various cable concepts using commercial long length REBCO coated conductors with high current-carrying performance. In the past few years, our group has successfully developed the Roebel cable concept for coated conductors. The design advantages of such a cable are high current-carrying capability and low alternating current (AC) losses. Unfortunately, for large-scale applications, the possibilities of a simple scale-up of the Roebel geometry are limited and additional design ideas are needed. One way to reach the required high currents is the Rutherford cable concept. In this concept a conductor is wound with transposition on a flat metal former. In order to design the former, the bending properties of the Roebel assembled coated conductor cables (RACC) must be measured and characterized. This allows the identification of a destruction-free interval for the Roebel cable, in terms of bending angle and transposition length. In this work we designed and assembled a demonstrator of a coated conductor Rutherford cable (CCRC) with three RACC cables. We measured the critical current and the AC losses of the cable demonstrator. Our results show that, despite still needing efforts in terms of reproducibility of the assembly process and of AC loss reduction, this design is a promising and viable solution for high current-capacity cables made of coated conductors.

A Kario; M Vojenciak; F Grilli; A Kling; B Ringsdorf; U Walschburger; S I Schlachter; W Goldacker

2013-01-01T23:59:59.000Z

154

International Symposium on High Voltage Engineering, London, August 1999 page 1 of 4  

E-Print Network (OSTI)

substations (GIS) are described. Calculated transfer functions are presented, showing that transverse electric) in gas insulated substations (GIS) has been described in detail previously [1]. In this paper, we present that occurs somewhere in the insulating region between the high voltage (HV) conductor and the metal cladding

Judd, Martin

155

Study of the electric field generated by the high voltage substations  

Science Journals Connector (OSTI)

The paper outlines the results of a study regarding the electromagnetic field generated by a 400 kV high voltage (HV) substation belonging to the Romanian national Power Grid Company Transelectrica SA. In the first part of the paper, a semi-analytical ... Keywords: HV substations, computation, electromagnetic field, human exposure, limits

Calin Munteanu; Vasile Topa; Marius Purcar; Laura Grindei; Adina Racasan

2010-10-01T23:59:59.000Z

156

Geomagnetically induced currents in the Uruguayan high-voltage power grid  

Science Journals Connector (OSTI)

......currents in the Uruguayan high-voltage power grid R. Caraballo 1 2 L. Sanchez Bettucci...simple topology of the Uruguayan power grid provides some advantages in the calculation...transformers at the South African power grid during the Halloween storm in 2003......

R. Caraballo; L. Sįnchez Bettucci; G. Tancredi

2013-01-01T23:59:59.000Z

157

Electro-optic imagery of high-voltage GaAs photoconductive switches  

SciTech Connect

The authors present electro-optic images of GaAs high-voltage photoconductive switches utilizing the electro-optic effect of the semi-insulating GaAs substrate. Experimental methodology for obtaining the images is described along with a self-calibrating data reduction algorithm. Use of the technique for observing fabrication defects is shown.

Falk, R.A.; Adams, J.C.; Capps, C.D.; Ferrier, S.G.; Krinsky, J.A. (Boeing Defense and Space Group, Seattle, WA (United States))

1995-01-01T23:59:59.000Z

158

An earth-isolated optically coupled wideband high voltage probe powered by ambient light  

E-Print Network (OSTI)

(2012) Optimized working conditions for a thermoelectric generator as a topping cycle for gas turbines J (2012) Feasibility study in application of forging waste heat on absorption cooling system J. Renewable-emitting diode that converts high voltage into an amplitude-modulated optical signal, which is then conveyed

Bellan, Paul M.

159

Effect of high solenoidal magnetic fields on breakdown voltages of high vacuum 805 MHz cavities  

SciTech Connect

There is an on going international collaboration studying the feasibility and cost of building a muon collider or neutrino factory [1,2]. An important aspect of this study is the full understanding of ionization cooling of muons by many orders of magnitude for the collider case. An important muon ionization cooling experiment, MICE [3], has been proposed to demonstrate and validate the technology that could be used for cooling. Ionization cooling is accomplished by passing a high-emittance muon beam alternately through regions of low Z material, such as liquid hydrogen, and very high accelerating RF Cavities within a multi-Tesla solenoidal field. To determine the effect of very large solenoidal magnetic fields on the generation of dark current, x-rays and on the breakdown voltage gradients of vacuum RF cavities, a test facility has been established at Fermilab in Lab G. This facility consists of a 12 MW 805 MHz RF station and a large warm bore 5 T solenoidal superconducting magnet containing a pill box type cavity with thin removable window apertures. This system allows dark current and breakdown studies of different window configurations and materials. The results of this study will be presented. The study has shown that the peak achievable accelerating gradient is reduced by a factor greater than 2 when solenoidal field of greater than 2 T are applied to the cavity.

Moretti, A.; Bross, A.; Geer, S.; Qian, Z.; /Fermilab; Norem, J.; /Argonne; Li, D.; Zisman, M.; /LBL, Berkeley; Torun, Y.; /IIT, Chicago; Rimmer, R.; /Jefferson Lab; Errede,; /Illinois U., Urbana

2005-10-01T23:59:59.000Z

160

Breaking the ice: de-icing power transmission lines with high-frequency, high-voltage excitation  

E-Print Network (OSTI)

Breaking the ice: de-icing power transmission lines with high-frequency, high-voltage excitation of this work in other works must be obtained from the IEEE. #12;CING OF POWER TRANSMISSION lines during winter that applies 33-kV, 100-kHz power. TheoverallsystemisillustratedinFigure1.Itcouldbede- ployed in two different

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Potential methods for the fabrication of high-T/sub c/ superconductors for wires and cables  

SciTech Connect

In this paper studies on practical properties, such as upper critical field and critical-current density of high-T/sub c/ oxide superconductors of Y-Ba-Cu-O, Bi-Sr-Ca-Cu-O, and Tl-Ba-Ca-Cu-O systems, are reviewed. Recent developments of fabrication processes that have good potentiality for producing wire or tape conductors of high-T/sub c/ oxide are then discussed. Some details are presented for the powder method (which is classified into use of an organic binder and a metal sheath) and for other fabrication processes using diffusion, solidification, and deposition techniques. For the Ag-sheathed oxide tapes, J/sub c/ values exceeding 10 000 A/cm/sup 2/ at 77 {Kappa} and 0 T have been reported for both Bi and Tl oxide materials. Further developments in fabrication processes that can overcome various problems limiting the transport J/sub c/ are required.

Tachikawa, K. (Tokai Univ., Hiratsuka, Kanagawa (Japan). Dept. of Physics); Togano, K. (National Research Inst. for Metals, Tsukuba, Ibaraki (Japan). Tsukuba Lab.)

1989-08-01T23:59:59.000Z

162

Apparatus for injecting high power laser light into a fiber optic cable  

DOE Patents (OSTI)

High intensity laser light is evenly injected into an optical fiber by the combination of a converging lens and a multisegment kinoform (binary optical element). The segments preferably have multi-order gratings on each which are aligned parallel to a radial line emanating from the center of the kinoform and pass through the center of the element. The grating in each segment causes circumferential (lateral) dispersion of the light, thereby avoiding detrimental concentration of light energy within the optical fiber.

Sweatt, William C. (Albuquerque, NM)

1997-01-01T23:59:59.000Z

163

Underground Power Cables  

Science Journals Connector (OSTI)

...1973 research-article Underground Power Cables J. D. Endacott Up to the present, effectively...particular, in recent years, the oil-filled cable system using cellulose paper impregnated...design of supertension underground power cable systems are considered. The limitations...

1973-01-01T23:59:59.000Z

164

Optical fiber imaging for high speed plasma motion diagnostics: Applied to low voltage circuit breakers  

SciTech Connect

An integrated portable measurement system is described for the study of high speed and high temperature unsteady plasma flows such as those found in the vicinity of high current switching arcs. An array of optical fibers allows the formation of low spatial resolution images, with a maximum capture rate of 1x10{sup 6} images per second (1 MHz), with 8 bit intensity resolution. Novel software techniques are reported to allow imaging of the arc; and to measure arc trajectories. Results are presented on high current (2 kA) discharge events in a model test fixture and on the application to a commercial low voltage circuit breaker.

McBride, J. W. [School of Engineering Sciences, University of Southampton, Highfield, Southampton SO17 1BJ (United Kingdom); Balestrero, A.; Tribulato, G. [ABB SACE DIVISION, ABB S.p.A., Via Baioni, Bergamo 35 IT-24123 (Italy); Ghezzi, L. [ABB SACE DIVISION, ABB S.p.A., Viale dell'Industria, Vittuone (MI)18 IT-20010 (Italy); Cross, K. J. [Taicaan Ltd., 2 Venture Road, Southampton Science Park, Southampton, Hampshire SO16 7NP (United Kingdom)

2010-05-15T23:59:59.000Z

165

High Voltage Performance of the Beam Screen of the LHC Injection Kicker Magnets  

E-Print Network (OSTI)

The LHC injection kicker magnets include beam screens to shield the ferrite yokes against wakefields resulting from the high intensity beam. The screening is provided by conductors lodged in the inner wall of a ceramic support tube. The design of the beam screen has been upgraded to overcome limitations and permit LHC operation with increasingly higher bunch intensity and short bunch lengths: the new design also significantly reduces the electric field associated with the screen conductors, decreasing the probability of electrical breakdown. The high voltage conditioning process for the upgraded kicker magnets is presented and discussed. In addition a test setup has been utilized to study flashover, on the inner wall of the ceramic tube, as a function of both applied voltage and vacuum pressure: results from the test setup are presented.

Barnes, MJ; Bregliozzi, G; Calatroni, S; Costa Pinto, P; Day, H; Ducimetičre, L; Kramer, T; Namora, V; Mertens, V; Taborelli, M

2014-01-01T23:59:59.000Z

166

Electronically controlled cable wrapper  

DOE Patents (OSTI)

A spindle assembly engages and moves along a length of cable to be wrapped with insulating tape. Reels of insulating tape are mounted on a outer rotatable spindle which revolves around the cable to dispense insulating tape. The rate of movement of the spindle assembly along the length of the cable is controlled by a stepper motor which is programmably synchronized to the rate at which rotatable spindle wraps the cable. The stepper motor drives a roller which engages the cable and moves the spindle assembly along the length of the cable as it is being wrapped. The spindle assembly is mounted at the end of an articulated arm which allows free movement of the spindle assembly and allows the spindle assembly to follow lateral movement of the cable.

Young, T.M.

1982-08-17T23:59:59.000Z

167

Round-robin artificial contamination test on high voltage dc insulators  

SciTech Connect

This paper summarizes the results of a worldwide round-robin test of high voltage dc (HVDC) insulators, which was carried out in six laboratories aiming at standardization of the method for artificial contamination tests on HVDC insulators. Flashover characteristics of three kinds of specimens were evaluated by the clean fog and the salt fog procedures. Sufficient information is now available to allow the preparation of provisional international specifications for artificial contamination testing of HVDC insulators.

Naito, K.; Schneider, H.M.

1995-07-01T23:59:59.000Z

168

Definition: Very Low Impedance (Hts) Cables | Open Energy Information  

Open Energy Info (EERE)

Very Low Impedance (Hts) Cables Very Low Impedance (Hts) Cables Jump to: navigation, search Dictionary.png Very Low Impedance (Hts) Cables Cables that use conducting materials that are very low impedance, which can enable better power flow control. Cables that use high temperature superconducting (HTS) conductor would be characterized as a VLI cable. HTS cables may enable additional benefits such as lower losses, increased power density, and self-fault limiting.[1] Related Terms power, power flow control References ā†‘ [www.smartgrid.gov/sites/default/files/pdfs/description_of_assets.pdf SmartGrid.gov 'Description of Assets'] An i LikeLike UnlikeLike You like this.Sign Up to see what your friends like. nline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Very_Low_Impedance_(Hts)_Cables&oldid=480440

169

CABLE TECHNOLOGY LABORATORIES, INC. DETERMINATION OF THRESHOLD...  

Office of Scientific and Technical Information (OSTI)

Aged Polymeric Dielectric Cable TABLE OF CONTENTS ABSTRACT INTRODUCTION DESCRIPTION OF TEST CABLES TEMPERATURE CONDITIONING OF TEST CABLES TESTING OF XLPE INSULATED CABLE BEFORE...

170

Modelling of interconnects including coaxial cables and multiconductor lines.  

E-Print Network (OSTI)

??In recent years, electromagnetic compatibility (EMC) problems associated with high frequency and high speed interconnects are becoming of increasing concern. Coaxial cables are a popular… (more)

Teo, Yu Xian

2013-01-01T23:59:59.000Z

171

The Pacific Telephone Cable  

Science Journals Connector (OSTI)

... ceremonies in Ottawa, Sydney, Wellington and Suva. The transmission was over the first telephone cable to be laid across the Pacific Ocean.

1964-02-08T23:59:59.000Z

172

Influence of energy contributions to a high-voltage atmospheric-pressure discharge on the efficiency of conversion of ethanol  

Science Journals Connector (OSTI)

The results of experimental investigations of the conversion of ethanol in a high-voltage atmospheric-pressure discharge have been presented. The influence of the energy parameters of the discharge on the yield a...

S. A. Zhdanok; A. V. Krauklis; P. P. Samtsov…

2006-11-01T23:59:59.000Z

173

A high voltage test stand for electron gun qualification for LINACs  

SciTech Connect

An electron gun lest stand has been developed at RRCAT. The test stand consists of a high voltage pulsed power supply, electron gun filament supply, grid supply, UHV system and electron gun current measurement system. Several electron guns developed indigenously were evaluated on this test stand. The shielding is provided for the electron gun set up. Electron gun tests can be tested upto 55 kV with pulse width of 15 microsecs and pulse repetition rates up to 200 Hz. The technical details of the subsystems are furnished and results of performance of the test stand have been reported in this paper. (author)

Wanmode, Yashwant D.; Mulchandani, J.; Acharya, M.; Bhisikar, A.; Singh, H.G.; Shrivastava, Purushottam, E-mail: yash@rrcat.gov.in [Pulsed High Power Microwave Section, Raja Ramanna Centre for Advanced Technology, Indore (India)

2011-07-01T23:59:59.000Z

174

A Fusing Switch for Fault Suppression in the SNS High Voltage Converter Modulators  

SciTech Connect

The High Voltage Converter Modulators (HVCMs) at the Spallation Neutron Source (SNS) have operated in excess of a combined 250,000 hours. Performance and reliability improvements to the HVCM are ongoing to increase modulator availability as accelerator system demands increase. There is a relatively large amount of energy storage in the HVCMs, {approx}180 kJ. This energy has the potential to dump into unsuppressed faults, cause damage, and increase the time to repair. The 'fusing switch' concept involves isolation of this stored energy from the location of the most common faults. This paper introduces this concept and its application to the HVCMs.

Kemp, Mark A.; Burkhart, Craig; Nguyen, Minh N.; /SLAC; Anderson, David E.; /Oak Ridge

2009-08-03T23:59:59.000Z

175

High voltage power supplies for the neutral beam injectors of the stellarator TJ-II  

Science Journals Connector (OSTI)

Neutral beam injection will be available for the second experimental phase of TJ-II. Two injectors, set in co-counter configuration, will inject into the plasma two 40 keV H0 beams, each of up to 1 MW. The two high voltage power supplies to feed the acceleration grids of the injectors, described in this paper, are of the transformer–rectifier type, taking their primary energy from a pulsed flywheel generator, and are coupled to the acceleration grids through a switching device. This environment effectively sets the main operation limits and protection requirements of the power supplies.

J Alonso; M Liniers; L Mart??nez Laso; E Jauregi; C Luc??a; F Valcįrcel

2001-01-01T23:59:59.000Z

176

Design Techniques for High Speed Low Voltage and Low Power Non-Calibrated Pipeline Analog to Digital Converters  

E-Print Network (OSTI)

DESIGN TECHNIQUES FOR HIGH SPEED LOW VOLTAGE AND LOW POWER NON-CALIBRATED PIPELINE ANALOG TO DIGITAL CONVERTERS A Dissertation by RIDA SHAWKY ASSAAD Submitted to the Office of Graduate Studies of Texas A&M University... in partial fulfillment of the requirements for the degree of DOCTOR OF PHILOSOPHY December 2009 Major Subject: Electrical Engineering DESIGN TECHNIQUES FOR HIGH SPEED LOW VOLTAGE AND LOW POWER NON-CALIBRATED PIPELINE ANALOG TO DIGITAL...

Assaad, Rida Shawky

2011-02-22T23:59:59.000Z

177

High-voltage nanosecond pulses in a low-pressure radio-frequency discharge  

Science Journals Connector (OSTI)

An influence of a high-voltage (3–17 kV) 20 ns pulse on a weakly-ionized low-pressure (0.1–10 Pa) capacitively coupled radiofrequency (RF) argon plasma is studied experimentally. The plasma evolution after pulse exhibits two characteristic regimes: a bright flash, occurring within 100 ns after the pulse (when the discharge emission increases by 2–3 orders of magnitude over the steady-state level), and a dark phase, lasting a few hundreds ?s (when the intensity of the discharge emission drops significantly below the steady-state level). The electron density increases during the flash and remains very large at the dark phase. 1D3V particle-in-cell simulations qualitatively reproduce both regimes and allow for detailed analysis of the underlying mechanisms. It is found that the high-voltage nanosecond pulse is capable of removing a significant fraction of plasma electrons out of the discharge gap, and that the flash is the result of the excitation of gas atoms, triggered by residual electrons accelerated in the electric field of immobile bulk ions. The secondary emission from the electrodes due to vacuum UV radiation plays an important role at this stage. High-density plasma generated during the flash provides efficient screening of the RF field (which sustains the steady-state plasma). This leads to the electron cooling and, hence, onset of the dark phase.

M. Y. Pustylnik; L. Hou; A. V. Ivlev; L. M. Vasilyak; L. Couėdel; H. M. Thomas; G. E. Morfill; V. E. Fortov

2013-06-10T23:59:59.000Z

178

Multistrand superconductor cable  

DOE Patents (OSTI)

Improved multistrand Rutherford-type superconductor cable is produced by using strands which are preformed, prior to being wound into the cable, so that each strand has a variable cross section, with successive portions having a substantially round cross section, a transitional oval cross section, a rectangular cross section, a transitional oval cross section, a round cross section and so forth, in repetitive cycles along the length of the strand. The cable is wound and flattened so that the portions of rectangular cross section extend across the two flat sides of the cable at the strand angle. The portions of round cross section are bent at the edges of the flattened cable, so as to extend between the two flat sides. The rectangular portions of the strands slide easily over one another, so as to facilitate flexing and bending of the cable, while also minimizing the possibility of causing damage to the strands by such flexing or bending. Moreover, the improved cable substantially maintains its compactness and cross-sectional shape when the cable is flexed or bent.

Borden, Albert R. (El Cerrito, CA)

1985-01-01T23:59:59.000Z

179

Fire-Immune Cable  

Science Journals Connector (OSTI)

... A FACTORY, opened by Lord Ridley on October 12, for making fire-resist ing cable called 'Pyrotenax', marks a new development which promises to be of far-reaching ... -plate elements, which are made of resistance wire embedded in the oxide. 'Pyrotenax' cable has a copper conductor, magnesia insulation, and copper sheath. The new technique enables ...

1937-11-20T23:59:59.000Z

180

TV cable in chains  

Science Journals Connector (OSTI)

... THE British Government's cable revolution will not now take place. Almost exactly a year ago, the cabinet's ... advisory panel on information technology declared that Britain must be swiftly rewired for 30-channel cable television or face the consequences: missing out on the information age. Until then the ...

1983-02-24T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Cable-Laying  

Science Journals Connector (OSTI)

... IT is somewhat remarkable that the business of making and laying submarine telegraph cables—which hitherto has been a monopoly of Great Britain, and employs large numbers of ... little understood by people not directly connected with it. Yet the daily history of any cable-laying expedition, if faithfully written, would contain matter of engrossing interest for all readers ...

J. Y. B.

1887-12-15T23:59:59.000Z

182

Duplexing the Atlantic Cable  

Science Journals Connector (OSTI)

... it is implied that the application of the duplex method of signalling to an Atlantic cable has now for the first time been successfully accomplished by Mr. Stearns. The publication ... to Mr. Stearns' predecessors jn the application of the duplex system to long submarine cables, and that their success has been something more than "only partial"in the opinion ...

HERBERT TAYLOR

1878-11-21T23:59:59.000Z

183

The scaling of transport AC losses in Roebel cables with varying strand parameters  

Science Journals Connector (OSTI)

A Roebel cable is a good candidate for low-voltage windings in a high-temperature superconductor (HTS) transformer because of its high current-carrying capability and low AC loss. Transport AC loss measurements were carried out in 1.8 m long 15/5 (fifteen 5 mm wide strands) and 15/4 Roebel cables. The results were compared with those in many Roebel cables composed of 2 mm wide Roebel strands. Comparison of the AC losses hinted that the intrinsic difference in normalized transport AC losses is due to differences in the g/w (ratio of the horizontal gap between the Roebel strands over the Roebel strand width) values. The intrinsic difference was confirmed by measuring transport AC loss in a series of horizontally arranged parallel conductor pairs with various g values. A method to scale transport AC losses in Roebel cables with varying strand parameters was developed. The scaling method will be useful for a rough assessment of AC loss in one-layer solenoid winding coils, such as in a HTS transformer.

Zhenan Jiang; Mike Staines; Nicholas J Long; Rodney A Badcock; Chris Bumby; Evgeny Talantsev; Kent Hamilton; Robert G Buckley; Naoyuki Amemiya

2014-01-01T23:59:59.000Z

184

Aerodynamics of a circular cylinder inclined to airflow and wind-induced vibrations of dry, inclined cables at high wind speeds .  

E-Print Network (OSTI)

??Cable-stayed bridges are an efficient and elegant solution to bridging long spans. Though a widely used structural system, several significant issues are still unresolved regarding… (more)

Zurell, Cory

2013-01-01T23:59:59.000Z

185

Monte Carlo method for estimating backflashover rates on high voltage transmission lines  

Science Journals Connector (OSTI)

Abstract This paper presents a novel Monte-Carlo based model for the analysis of backflashover rate (BFOR) on high voltage transmission lines. The proposed model aims to take into the account following aspects of the BFOR phenomenon: transmission line (TL) route keraunic level(s), statistical depiction of lightning-current parameters (including statistical correlation), electrogeometric model of lightning attachment, frequency-dependence of TL parameters and electromagnetic coupling effects, tower geometry and surge impedance, tower grounding impulse impedance (with soil ionization), lightning-surge reflections from adjacent towers, non-linearity of the insulator strings flashover characteristic, distribution of lightning strokes along the TL span and power frequency voltage. In the analysis of the BFOR, special attention is given to the influences emanating from the insulator strings flashover characteristic and lightning statistics. The model could be applied to the transmission line as a whole or some of its portions, e.g. first several towers emanating from the substation or several towers crossing a mountain ridge.

Petar Sarajcev

2015-01-01T23:59:59.000Z

186

Design and Fabrication of a High Voltage Distribution Box Michael Barnett  

E-Print Network (OSTI)

of paint. This ensured that the lock washers for the BNC plugs made solid electrical contacts with the box the shielding of the coaxial RG47 cable continuous, which helped to reduce noise injection into the lines. The BNC ports were manufactured by KINGS, part no. 1704-1. They used a lock washer and a threaded nut

Saskatchewan, University of

187

Monolithically interconnected GaAs solar cells: A new interconnection technology for high voltage solar cell output  

SciTech Connect

Photovoltaic linear concentrator arrays can benefit from high performance solar cell technologies being developed at AstroPower. Specifically, these are the integration of thin GaAs solar cell and epitaxial lateral overgrowth technologies with the application of monolithically interconnected solar cell (MISC) techniques. This MISC array has several advantages which make it ideal for space concentrator systems. These are high system voltage, reliable low cost monolithically formed interconnections, design flexibility, costs that are independent of array voltage, and low power loss from shorts, opens, and impact damage. This concentrator solar cell will incorporate the benefits of light trapping by growing the device active layers over a low-cost, simple, PECVD deposited silicon/silicon dioxide Bragg reflector. The high voltage-low current output results in minimal 12R losses while properly designing the device allows for minimal shading and resistance losses. It is possible to obtain open circuit voltages as high as 67 volts/cm of solar cell length with existing technology. The projected power density for the high performance device is 5 kW/m for an AMO efficiency of 26% at 1 5X. Concentrator solar cell arrays are necessary to meet the power requirements of specific mission platforms and can supply high voltage power for electric propulsion systems. It is anticipated that the high efficiency, GaAs monolithically interconnected linear concentrator solar cell array will enjoy widespread application for space based solar power needs. Additional applications include remote man-portable or ultra-light unmanned air vehicle (UAV) power supplies where high power per area, high radiation hardness and a high bus voltage or low bus current are important. The monolithic approach has a number of inherent advantages, including reduced cost per interconnect and increased reliability of array connections. There is also a high potential for a large number of consumer products.

Dinetta, L.C.; Hannon, M.H.

1995-10-01T23:59:59.000Z

188

Correction coil cable  

DOE Patents (OSTI)

A wire cable assembly adapted for the winding of electrical coils is taught. A primary intended use is for use in particle tube assemblies for the Superconducting Super Collider. The correction coil cables have wires collected in wire array with a center rib sandwiched therebetween to form a core assembly. The core assembly is surrounded by an assembly housing having an inner spiral wrap and a counter wound outer spiral wrap. An alternate embodiment of the invention is rolled into a keystoned shape to improve radial alignment of the correction coil cable on a particle tube in a particle tube assembly. 7 figs.

Wang, S.T.

1994-11-01T23:59:59.000Z

189

ANUEADflM-31 Electric Power High-Voltage Transmission Lines:  

Office of Scientific and Technical Information (OSTI)

ANUEADflM-31 ANUEADflM-31 Electric Power High-Voltage Transmission Lines: Design Options, Cost, and Electric and Magnetic Field Levels by J.B. Stoffel,' E.D. Pentecost, R.D. Roman, and P.A. Traczyk Environmental Assessment Division, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 November 1994 Work sponsored by United States Department of Energy, Assistant Secretary for Fossil Energy, Office of Fuels Program Stoffel is affiliated with Argonne's Electronics and Computing Technologies Division. D4SlRlBUTlON OF THIS DOCUMENT IS UNLiMltEb - . - . - . - . ... - , . ^ ~ .. , . . . , . . _ I T h i s report i s printed on recycled paper. @ . . .. . ' . . . A :_ - .. ., . . DISCLAIMER This report was .prepared as an account of work sponsored by an agency of the United States Government. Neither

190

ESS 2012 Peer Review - Low Cost, Manufacturable High Voltage Power Module for ESS - Brandon Passmore, APEI  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

W. Research Center Blvd. * Fayetteville, AR 72701 * (479) 443-5759 W. Research Center Blvd. * Fayetteville, AR 72701 * (479) 443-5759 Design and Development of a Low Cost, Manufacturable High Voltage Power Module for Energy Storage Systems Phase I SBIR September 27, 2012 Brandon Passmore, PhD Sr. Electronics Packaging Research Engineer Email: bpassmo@apei.net Acknowledgements * I would like to thank Dr. Imre Gyuk of the DOE Energy Storage Systems Program and Dr. Stan Atcitty for technical support * I would also like to thank 2 Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

191

Artificial SEI Enables High-Voltage Lithium-ion Batteries | ornl.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Functional Materials for Energy Functional Materials for Energy Artificial SEI Enables High-Voltage Lithium-ion Batteries September 03, 2013 Efficacy of Lipon coating as an artificial SEI for suppression of electrolyte decomposition on a 5V spinel cathode: coulombic efficiency was measured versus cycle numbers at samples with different coating thickness. An artificial solid electrolyte interphase (SEI) of lithium phosphorus oxynitride (Lipon) enables the use of 5V cathode materials with conventional carbonate electrolytes in lithium-ion batteries. Five volt cathode materials, such as LiNi0.5Mn1.5O4, are desirable to provide higher energy, however conventional carbonate electrolytes decompose above 4.5V compromising the battery performance. This work shows that Lipon coating suppresses the electrolyte decomposition, as measured by the

192

High open circuit voltages of solar cells based on quantum dot and dye hybrid-sensitization  

SciTech Connect

A type of solar cell based on quantum dot (QD) and dye hybrid-sensitized mesoporous TiO{sub 2} film electrode was designed and reported. The electrode was consisted of a TiO{sub 2} nanoparticle (NP) thin film layer sensitized with CdS quantum dot (QD) and an amorphous TiO{sub 2} coated TiO{sub 2} NP thin film layer that sensitized with C106 dye. The amorphous TiO{sub 2} layer was obtained by TiCl{sub 4} post-treatment to improve the properties of solar cells. Research showed that the solar cells fabricated with as-prepared hybrid-sensitized electrode exhibited excellent photovoltaic performances and a fairly high open circuit voltage of 796?mV was achieved.

Zhao, Yujie; Zhao, Wanyu; Chen, Jingkuo; Li, Huayang; Fu, Wuyou, E-mail: hari@hpu.edu.cn, E-mail: fuwy56@163.com; Sun, Guang; Cao, Jianliang; Zhang, Zhanying [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China)] [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China); Bala, Hari, E-mail: hari@hpu.edu.cn, E-mail: fuwy56@163.com [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China) [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China); College of Chemistry and Chemical Engineering, Inner Mongolia University for the Nationalities, Tongliao 028043 (China)

2014-01-06T23:59:59.000Z

193

Constructing ‘population’ criteria for the comparison of different options for a high voltage line route  

Science Journals Connector (OSTI)

This paper presents a method for comparing the sensitiveness of people to different possible options for the route of High Voltage transmission lines. It has been tested on practical cases. First, we create special dimensions and scales in order to evaluate the different zones of a studied area. Then, the different options for the route of HV lines (which are a succession of different zones) have to be compared. The construction of criteria permitting the comparison of different options raises a theoretical issue: how to punctualise the geographic distribution or the grades of the different zones of an option, in order to reflect preferences? Different methods of punctualisation are proposed which could apply to other cases. But the purpose of the paper is merely to show that these methods of punctualisation are not neutral, they cannot reflect all the characteristics of a distribution of grades.

Nathalie Grassin

1986-01-01T23:59:59.000Z

194

Telecommunications Cable Modem  

E-Print Network (OSTI)

Telecommunications Cable Modem 1. Fax the completed form to 979.847.1111. 2. If you do not receive Service Date Desired Telecommunications Office Use Only Service Due Date Installation Cost (NRC) Billed

195

Low-Variation 1 MHz Clock Generator,High Sensitivity Linear Voltage-to-Frequency Converter,and High-PSR Bias Circuit for NTSC SYNC Separation.  

E-Print Network (OSTI)

??This thesis includes three topics. The first topic is a low-variation 1 MHz clock generator. The second one is a high sensitivity linear voltage-to-frequency converter.… (more)

Lee, Tzung-Je

2004-01-01T23:59:59.000Z

196

1981). Their basic solution is to find a suitable backfilling material to minimize the contact resistance and to maintain high ground thermal conductivity around the cable even under very  

E-Print Network (OSTI)

#12;1981). Their basic solution is to find a suitable backfilling material to minimize the contact resistance and to maintain high ground thermal conductivity around the cable even under very dry ground contact resistance or soil dry-out or both. This paper presents a mathematical model describing

Oak Ridge National Laboratory

197

New live line tester for porcelain suspension insulators on high-voltage power lines  

SciTech Connect

Suspension insulator assemblies known as insulator strings are used in overhead power transmission lines to mechanically support high-voltage conductors while providing adequate insulation to withstand switching and lightning overvoltages. Since the useful life in service of the individual insulator elements making up these strings is hard to predict, they must be verified periodically to insure that adequate line reliability is maintained at all times. Over the years many testing methods have been used for this purpose, each one with its own advantages and disadvantages. Until now at Hydro-Quebec, porcelain insulators had been tested by the buzz method which simply consists of applying a short-circuit to each insulator in a string and listening for a buzz-like sound indicating a good insulator. However, safety considerations that preclude short-circuiting insulators and other disadvantages of that method have led Hydro-Quebec to undertake and complete the development of a new insulator tester. The working principle of this new device is based on the automatic measurement and recording of the electric field along the insulator string which decreases considerably in front of an internally-shorted insulator. The tester is slid along the string while the insulators are counted automatically. The information from tests on up to 200 strings can be stored in the device to be later transferred in a host computer for interpretation and/or permanent storage. The new tester also gives information on voltage distribution along the insulator strings which can be useful for the design of future power transmission lines.

Vaillancourt, G.H.; St-Jean, M. (Hydro-Quebec, Varennes, Quebec (Canada)); Bellerive, J.P. (Hydro-Quebec, Montreal, Quebec (Canada)); Jean, C. (Positron Inc., Montreal, Quebec (Canada))

1994-01-01T23:59:59.000Z

198

Mechanisms of deflagration-to-detonation transition under initiation by high-voltage nanosecond discharges  

SciTech Connect

An experimental study of detonation initiation in a stoichiometric propane-oxygen mixture by a high-voltage nanosecond gas discharge was performed in a detonation tube with a single-cell discharge chamber. The discharge study performed in this geometry showed that three modes of discharge development were realized under the experimental conditions: a spark mode with high-temperature channel formation, a streamer mode with nonuniform gas excitation, and a transient mode. Under spark and transient initiation, simultaneous ignition inside the discharge channel occurred, forming a shock wave and leading to a conventional deflagration-to-detonation transition (DDT) via an adiabatic explosion. The DDT length and time at 1 bar of initial pressure in the square smooth tube with a 20-mm transverse size amounted to 50 mm and 50{mu}s, respectively. The streamer mode of discharge development at an initial pressure of 1 bar resulted in nonuniform mixture excitation and a successful DDT via a gradient mechanism, which was confirmed by high-speed time resolved ICCD imaging. The gradient mechanism implied a longer DDT time of 150{mu}s, a DDT run-up distance of 50 mm, and an initiation energy of 1 J, which is two orders of magnitude less than the direct initiation energy for a planar detonation under these conditions. (author)

Rakitin, Aleksandr E.; Starikovskii, Andrei Yu. [Physics of Nonequilibrium Systems Lab, Moscow Institute of Physics and Technology, 9 Institutski Lane, Dolgoprudny 141700 (Russian Federation)

2008-10-15T23:59:59.000Z

199

Development of superconducting transmission cable. CRADA final report  

SciTech Connect

The purpose of this Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and Southwire Company is to develop the technology necessary to proceed to commercialization of high-temperature superconducting (HTS) transmission cables. Power transmission cables are a promising near-term electric utility application for high-temperature superconductivity. Present HTS wires match the needs for a three-phase transmission cable: (1) the wires must conduct high currents in self-field, (2) there are no high forces developed, and (3) the cables may operate at relatively low current density. The commercially-available HTS wires, in 100-m lengths, make construction of a full three-phase, alternating current (ac) transmission cable possible. If completed through the pre-commercialization phase, this project will result in a new capability for electric power companies. The superconducting cable will enable delivery with greater efficiency, higher power density, and lower costs than many alternatives now on the market. Job creation in the US is expected as US manufacturers supply transmission cables to the expanding markets in Asia and to the densely populated European cities where pipe-type cable is prevalent. Finally, superconducting cables may enable delivery of the new, diverse and distributed sources of electricity that will constitute the majority of new installed electrical generation in the world during the coming decades.

Hawsey, R.; Stovall, J.P. [Oak Ridge National Lab., TN (United States); Hughey, R.L.; Sinha, U.K. [Southwire Co., Carrollton, GA (United States)

1997-10-01T23:59:59.000Z

200

Application of evolutionary algorithms for the planning of urban distribution networks of medium voltage  

E-Print Network (OSTI)

Abstract—Currently, an important issue in power distribution is the need to optimize medium voltage (mv) networks serving urban areas. This paper shows how an evolutionary algorithm can be used as the basis for the type of efficient algorithm such optimization demands. The search for optimal network solution will be restricted to a graph defined from the urban map, so each graph branch represents a trench. The solution space (networks) is assumed with “loop feeder circuits”: networks with two electrical paths from the high voltage/medium voltage (hv/mv) substations to the customers. In the optimization process, the investment and loss load costs are considered taking into account the constraints of conductor capacities and voltage drop. The investment costs will take into account that some cables can be lying in the same trench. The process was applied for a Spanish city of 200 000 inhabitants. Index Terms—Evolutionary algorithm, medium voltage network planning, network design, urban distribution network. I.

unknown authors

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Project Fact Sheet Columbus HTS Power Cable Superconductivity  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Columbus Columbus HTS Power Cable Superconductivity Partnerships with Industry www.oe.energy.gov Phone: 202 \ 586-1411 Office of Electricity Delivery and Energy Reliability, OE-1 U.S. Department of Energy - 1000 Independence Avenue, SW - Washington, DC 20585 Plugging America Into the Future of Power This project involves field-testing of a long-length high-temperature superconducting (HTS) cable under real environmental stresses and real electrical loads. The cable system forms an important electrical link in a util- ity substation in Columbus, Ohio. What are its Primary aPPlications? HTS power cables are used for electricity transmission and distribution. The Columbus cable is a distribution cable, conducting electricity within a local grid. What are the Benefits to Utilities?

202

A three-level buck converter to regulate a high-voltage DC-to-AC inverter  

E-Print Network (OSTI)

A three-level buck converter is designed and analyzed, and shown to be suitable as a high-voltage down converter as a pre-regulation stage for a 600 watt DC-to-AC power inverter. Topology selection for the inverter is ...

Schrock, Kenneth C

2008-01-01T23:59:59.000Z

203

Leveraging the LEDA high voltage power supply systems for the LANSCE refurbishment project  

SciTech Connect

The LANSCE Refurbishment Project (LANSCE-R) will revitalize the LANSCE accelerator infrastructure. Much of the equipment has been in use for over 39 years and is approaching the end of its design lifetime. As obsolescence issues make like-for-like replacements increasingly more expensive, modern systems with lower costs become a reasonable alternative. As part of the LANSCE-R project, four of the seven HV power supplies for the 805 MHz RF klystrons will be replaced. The present and future requirements for these power supplies influence the selection of replacement options. Details of the HV power supply replacement requirements and the different replacement options will be discussed. One option is to use four 95 kV, 21 A DC power supplies originally installed nearby as part of the Low Energy Demonstration Accelerator (LEDA) project. Significant material and labor cost savings can be achieved by leaving these supplies installed where they are and building a HV transport system to bring high voltage power from the existing LEDA facility to the LANSCE facility. The different replacement options will be compared based on material and labor costs as offset by long-term energy savings.

Bradley Iii, Joseph Thomas [Los Alamos National Laboratory; Rees, Daniel E [Los Alamos National Laboratory; Roybal, William T [Los Alamos National Laboratory; Young, Karen A [Los Alamos National Laboratory

2008-01-01T23:59:59.000Z

204

Redesign of the H-Bridge Switch Plate of the SNS High Voltage Converter Modulator  

SciTech Connect

The 1-MW High Voltage Converter Modulators [1] have operated in excess of 250,000 hours at the Spallation Neutron Source. Increased demands on the accelerator performance require increased modulator reliability. An effort is underway at SLAC National Accelerator Laboratory to redesign the modulator H-bridge switch plate with the goals of increasing reliability and performance [2]. The major difference between the SLAC design and the existing design is the use of press-pack IGBTs. Compared to other packaging options, these IGBTs have been shown to have increased performance in pulsed-power applications, have increased cooling capability, and do not fragment and disassemble during a fault event. An overview of the SLAC switch plate redesign is presented. Design steps including electrical modeling of the modulator and H-bridge, development of an integrated IGBT clamping mechanism, and fault tests are discussed. Experimental results will be presented comparing electrical performance of the SLAC switch plate to the existing switchplate under normal and fault conditions.

Kemp, M.A.; Burkhart, C.; Nguyen, M.N.; /SLAC; Anderson, D.E.; /Oak Ridge

2009-05-07T23:59:59.000Z

205

Monitoring the magnetic field in houses under 50 Hz high-voltage overhead transmission lines  

Science Journals Connector (OSTI)

This paper deals with a one-week monitoring of the 50 Hz magnetic field on the ground floor and the first floor of houses under 150, 220 and 380 kV high-voltage overhead three-phase AC transmission lines. The field strength varied with the current intensity, the conductor height, and the storey of the house. Because current intensity varies with time the magnetic field depended on the time of day and the day of the week. The recorded magnetic field ranged from 0.1 µT to 4.5 µT. The maximum value was at least 20 times weaker than the 100 µT exposure level recommended by the guidelines of the International Radiation Protection Association (IRPA) and about 140 times smaller than the 640 µT of the European Prestandard (CENELEC). The B-field was, for 99.9% of the measuring time, larger than the 0.2 µT cut-off point used to define categories of exposed and unexposed subjects in EMF epidemiological studies and, for 99.3% of the time, was greater than the 0.3 µT level used by US private engineering companies as the 'prudent avoidance' exposure limit. The weakest average magnetic field was at least 40 times larger than the 0.02 µT background value.

G. Decat; J. Van Tongerloo

1998-01-01T23:59:59.000Z

206

Electron Energy Analysis of Vacuum Discharge in High-Voltage Accelerator Tube  

Science Journals Connector (OSTI)

......measurement of the electron energy spectrum during discharge adds some new knowledge to the total voltage...authors sincerely thank Electron Energy Analysis of Vacuum Discharge...Physics, Academic Press, New York, Vol. 6, p. 297. 25......

Akio TAKAOKA; Katsumi URA; Kiyokazu YOSHIDA

1982-01-01T23:59:59.000Z

207

A cable feeder tool for robotized cable winding  

Science Journals Connector (OSTI)

Abstract Cable winding is an alternative technology to create stator windings in large electrical machines. Today such cable winding is performed manually, which is very repetitive, time-consuming and therefore also expensive. This paper presents the design, function and control system of a developed cable feeder tool for robotized stator cable winding. The presented tool was able to catch a cable inside a cable guiding system and to grab the cable between two wheels. One of these wheels was used to feed cable through the feeder. A control system was integrated in the tool to detect feeding slippage and to supervise the feeding force on the cable. Functions to calculate the cable feed length, to release the cable from the tool and for positional calibration of the stator to be wound were also integrated in the tool. In validating the function of the cable feeder tool, the stator of the linear generator used in the Wave Energy Converter generator developed at Uppsala University was used as an example. Through these experiments, it was shown that the developed robot tool design could be used to achieve automated robotized cable winding. These results also complied with the cycle time assumptions for automated cable winding from earlier research. Hence, it was theoretically indicated that the total winding cycle time for one Uppsala University Wave Energy Converter stator could be reduced from about 80 h for manual winding with four personnel to less than 20 h in a fully developed cable winding robot cell. The same robot tool and winding automation could also be used, with minor adjustments, for other stator designs.

Erik Hultman; Mats Leijon

2014-01-01T23:59:59.000Z

208

On Trees as Equivalent Cables  

Science Journals Connector (OSTI)

...1993 research-article On Trees as Equivalent Cables R. R. Whitehead J. R. Rosenberg By means...reduced to an equivalent, possibly non-uniform cable. Under certain conditions the equivalent cable has disjoint sections of which only one communicates...

1993-01-01T23:59:59.000Z

209

Submarine Cable Interference  

Science Journals Connector (OSTI)

... THE description given by E. T. Burton1 of his measurements of audio frequency interference is of great interest, and would be more so if quantitative values ... , and hence to the permissible amplification, both at low frequencies for telegraphy and at audio frequencies for telephony. The recent suggestions for a loaded trans-Atlantic telephone cable 2 ...

A. L. MEYERS

1930-08-02T23:59:59.000Z

210

Scalable High-Power Redox Capacitors with Aligned Nanoforests of Crystalline MnO2 Nanorods by High Voltage Electrophoretic Deposition  

Science Journals Connector (OSTI)

Scalable High-Power Redox Capacitors with Aligned Nanoforests of Crystalline MnO2 Nanorods by High Voltage Electrophoretic Deposition ... The scalable nanomanufacturing process is demonstrated by roll-printing an aligned forest of ?-MnO2 nanorods on a large flexible substrate (1 inch by 1 foot). ...

Sunand Santhanagopalan; Anirudh Balram; Dennis Desheng Meng

2013-02-01T23:59:59.000Z

211

Disposable telemetry cable deployment system  

DOE Patents (OSTI)

A disposable telemetry cable deployment system for facilitating information retrieval while drilling a well includes a cable spool adapted for insertion into a drill string and an unarmored fiber optic cable spooled onto the spool cable and having a downhole end and a stinger end. Connected to the cable spool is a rigid stinger which extends through a kelly of the drilling apparatus. A data transmission device for transmitting data to a data acquisition system is disposed either within or on the upper end of the rigid stinger.

Holcomb, David Joseph (Sandia Park, NM)

2000-01-01T23:59:59.000Z

212

High voltage capability electrical coils insulated with materials containing SF.sub.6 gas  

DOE Patents (OSTI)

A coil is made having a plurality of layers of adjacent metal conductor windings subject to voltage stress, where the windings have insulation therebetween containing a small number of minute disposed throughout its cross-section, where the voids are voids filled with SF.sub.6 gas to substitute for air or other gaseous materials in from about 60% to about 95% of the cross-sectional void volume in the insulation, thus incorporating an amount of SF.sub.6 gas in the cross-section of the insulation effective to substantially increase corona inception voltages.

Lanoue, Thomas J. (Muncie, IN); Zeise, Clarence L. (Penn Township, Allegheny County, PA); Wagenaar, Loren (Muncie, IN); Westervelt, Dean C. (Acme, PA)

1988-01-01T23:59:59.000Z

213

Room-temperature atmospheric argon plasma jet sustained with submicrosecond high-voltage pulses  

SciTech Connect

In this letter, an experimental study is presented to characterize a room-temperature plasma jet in atmospheric argon generated with submicrosecond voltage pulses at 4 kHz. Distinct from sinusoidally produced argon discharges that are prone to thermal runaway instabilities, the pulsed atmospheric argon plasma jet is stable and cold with an electron density 3.9 times greater than that in a comparable sinusoidal jet. Its optical emission is also much stronger. Electrical measurement suggests that the discharge event is preceded with a prebreakdown phase and its plasma stability is facilitated by the short voltage pulses.

Walsh, J. L.; Kong, M. G. [Department of Electronic and Electrical Engineering, Loughborough University, Loughborough, Leicestershire LE11 3TU (United Kingdom)

2007-11-26T23:59:59.000Z

214

Some Features of an Electrostatic Generator and Ion Source for High Voltage Research  

Science Journals Connector (OSTI)

A compact generator of the Van de Graaff type is described in which several new features have been incorporated. Short-circuit current of one milliampere is available. When operating at 600 kv as voltage supply for accelerating protons or deutersons, 130?a of charged particles at the target have been obtained from an unusual low voltage capillary arc source. In normal operation as a neutron generator, the equivalent of 15 curies of radon-beryllium is readily produced by the reaction Li+D, and 60 curies by the D on D reaction.

I. A. Getting; J. B. Fisk; H. G. Vogt

1939-12-01T23:59:59.000Z

215

Over-expression of Cables 1 induces apoptosis in gynecological cancer cells  

Science Journals Connector (OSTI)

...San Diego, CA Over-expression of Cables 1 induces apoptosis in gynecological cancer...Apr 12-16, 2008; San Diego, CA 2604 Cables 1 is a cyclin-dependent kinase binding...previously reported that loss of nuclear Cables 1 expression was observed with high frequency...

Hideo Sakamoto; Maureen Lynch; Rosemary Foster; Lawrence Zukerberg; Bo Rueda

2008-05-01T23:59:59.000Z

216

Failure of simian virus 40 small t antigen to disorganize actin cables in nonpermissive cell lines.  

Science Journals Connector (OSTI)

...40 small t antigen to disorganize actin cables in nonpermissive cell lines. B Phillips...the clones had highly organized actin cables, as did parental 10T1/2 cells infected...40 small t antigen to disorganize actin cables in nonpermissive cell lines. | Mouse...

B Phillips; K Rundell

1988-03-01T23:59:59.000Z

217

V-1 TRANSITION AND N-VALUE OF MULTIFILAMENTARY LTS AND HTS WIRES AND CABLES.  

SciTech Connect

For low T, multifilamentary conductors like NbTi and Nb{sub 3}Sn, the V-I transition to the normal state is typically quantified by the parameter, n, defined by ({rho}/{rho}{sub c})= (I/I{sub c}){sup n}. For NbTi, this parameterization has been very useful in the development of high Jc wires, where the n-value is regarded as an index of the filament quality. In copper-matrix wires with undistorted filaments, the n-value at 5T is {approx} 40-60, and drops monotonically with increasing field. However, n can vary significantly in conductors with higher resistivity matrices and those with a low copper fraction. Usually high n-values are associated with unstable resistive behavior and premature quenching. The n-value in NbTi Rutherford cables, when compared to that in the wires is useful in evaluating cabling degradation of the critical current due to compaction at the edges of the cable. In Nb{sub 3}Sn wires, n-value has been a less useful tool, since often the resistive transition shows small voltages {approx} a few {mu}V prior to quenching. However, in ''well behaved'' wires, n is {approx} 30-40 at 12T and also shows a monotonic behavior with field. Strain induced I{sub c} degradation in these wires is usually associated with lower n-values. For high T{sub c} multifilamentary wires and tapes, a similar power law often describes the resistive transition. At 4.2K, Bi-2223 tapes as well as Bi-2212 wires exhibit n-values {approx} 15-20. In either case, n does not change appreciably with field. Rutherford cables of Bi-2212 wire show lower values of n than the virgin wire.

GHOSH,A.K.

2003-05-25T23:59:59.000Z

218

Impact of High Wind Penetration on the Voltage Profile of Distribution Systems  

E-Print Network (OSTI)

that the inclusion of squirrel cage induction generator (SCIG) does not have a large influence on transient stability to the inability of induction generator to support the reactive power. So, the main objective of this study generation on the voltage profile in distribution systems have been presented. The analysis is carried out

Pota, Himanshu Roy

219

Plasma Immersion Ion Implantation with a 4kV/10kHz Compact High Voltage Pulser  

SciTech Connect

Development of a 4 kV/10 kHz Compact High Voltage Pulser and its application to nitrogen plasma immersion ion implantation (PIII) of different materials as Si, Al alloys, SS304 stainless steel and Ti alloys are discussed. Low voltage (1-5 kV) pulses at high frequencies (up to 20 kHz for 2 kV) were obtained with maximum power delivered at 5 kV, 7 kHz. These conditions were not sufficient to reach temperatures above 200 deg. C in the samples because of short duration of the pulses. However, very shallow implantations of nitrogen in Si, Al5052, SS304 were observed by Auger electron spectroscopy and improved corrosion resistance was obtained for Al5052 when it was treated by nitrogen PIII at 2.5 kV, 5{mu}s and 5 kHz pulses.

Ueda, M.; Oliveira, R. M.; Rossi, J. O. [Associated Laboratory of Plasma, National Institute for Space Research, Av. dos Astronautas 1758, Sao Jose dos Campos, Sao Paulo (Brazil); Reuther, H. [Institute of Ion Beam Physics and Materials Research, Rossendorf, Dresden (Germany); Silva, G. [Associated Laboratory of Plasma, National Institute for Space Research, Av. dos Astronautas 1758, Sao Jose dos Campos, Sao Paulo (Brazil); Department of Aeronautics and Mechanics, Technological Institute of Aeronautics, Sao Jose dos Campos, Sao Paulo (Brazil)

2006-11-13T23:59:59.000Z

220

Using Dielectric Losses to De-Ice Power Transmission Lines with 100 kHz High-Voltage  

E-Print Network (OSTI)

capable of exciting a 1 m test line to 30 kV has been tested and show to be capable of removing a 7 mm iceUsing Dielectric Losses to De-Ice Power Transmission Lines with 100 kHz High-Voltage Excitation J DIELECTRIC LOSSES TO DE-ICE POWER TRANSMISSION LINES . . . 1 Using Dielectric Losses to De-Ice Power

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Method to improve superconductor cable  

DOE Patents (OSTI)

A method is disclosed of making a stranded superconductor cable having improved flexing and bending characteristics. In such method, a plurality of superconductor strands are helically wound around a cylindrical portion of a mandrel which tapers along a transitional portion to a flat end portion. The helically wound strands form a multistrand hollow cable which is partially flattened by pressure rollers as the cable travels along the transitional portion. The partially flattened cable is impacted with repeated hammer blows as the hollow cable travels along the flat end portion. The hammer blows flatten both the internal and the external surfaces of the strands. The cable is fully flattened and compacted by two sets of pressure rollers which engage the flat sides and the edges of the cable after it has traveled away from the flat end portion of the mandrel. The flattened internal surfaces slide easily over one another when the cable is flexed or bent so that there is very little possibility that the cable will be damaged by the necessary flexing and bending required to wind the cable into magnet coils.

Borden, A.R.

1984-03-08T23:59:59.000Z

222

Thermal management of long-length HTS cable systems  

SciTech Connect

Projections of electric power production suggest a major shift to renewables, such as wind and solar, which will be in remote locations where massive quantities of power are available. One solution for transmitting this power over long distances to load centers is direct current (dc), high temperature superconducting (HTS) cables. Electric transmission via dc cables promises to be effective because of the low-loss, highcurrent- carrying capability of HTS wire at cryogenic temperatures. However, the thermal management system for the cable must be carefully designed to achieve reliable and energyefficient operation. Here we extend the analysis of a superconducting dc cable concept proposed by the Electric Power Research Institute (EPRI), which has one stream of liquid nitrogen flowing in a cryogenic enclosure that includes the power cable, and a separate return tube for the nitrogen. Refrigeration stations positioned every 10 to 20 km cool both nitrogen streams. Both go and return lines are contained in a single vacuum/cryogenic envelope. Other coolants, including gaseous helium and gaseous hydrogen, could provide potential advantages, though they bring some technical challenges to the operation of long-length HTS dc cable systems. A discussion of the heat produced in superconducting cables and a system to remove the heat are discussed. Also, an analysis of the use of various cryogenic fluids in long-distance HTS power cables is presented.

Demko, Jonathan A [ORNL; Hassenzahl, William V [ORNL

2011-01-01T23:59:59.000Z

223

3D MHD modelling of the glidarc behaviour of a low current high voltage DC plasma torch Journal of Physics D: Applied Physics  

E-Print Network (OSTI)

in terms of: global behaviour, arc length, mean voltage and glidarc frequency. 1. Introduction The non-thermal on magnetohydrodynamic (MHD) modelling of atmospheric pressure direct current (DC) plasma torch operating at low current3D MHD modelling of the glidarc behaviour of a low current Ā­ high voltage DC plasma torch Journal

Paris-Sud XI, UniversitƩ de

224

Observations of Transport Variability in the Baltic Sea by Parasitic Use of a Fiber-Optic Cable  

Science Journals Connector (OSTI)

Transports between the Swedish mainland and the island of Gotland were studied by means of motionally induced voltages. The copper mantle of an existent fiber-optic telecommunications cable was grounded on Gotland, and the data acquisition system ...

Peter Sigray; Peter Lundberg; Kristofer Döös

2004-07-01T23:59:59.000Z

225

Microminiature coaxial cable and methods manufacture  

DOE Patents (OSTI)

A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 [mu]m thick and from 150 to 200 [mu]m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microballoons to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion. 2 figs.

Bongianni, W.L.

1986-04-08T23:59:59.000Z

226

Microminiature coaxial cable and methods of manufacture  

DOE Patents (OSTI)

A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 ..mu..m thick and from 150 to 200 ..mu..m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dieleectric. Alternately the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microballoons to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion.

Bongianni, W.L.

1983-12-29T23:59:59.000Z

227

Microminiature coaxial cable and method of manufacture  

DOE Patents (OSTI)

A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 .mu.m thick and from 150 to 200 .mu.m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately, the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microspheres to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion.

Bongianni, Wayne L. (Los Alamos, NM)

1989-01-01T23:59:59.000Z

228

Microminiature coaxial cable and method of manufacture  

DOE Patents (OSTI)

A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 [mu]m thick and from 150 to 200 [mu]m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately, the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microspheres to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion. 2 figs.

Bongianni, W.L.

1989-03-28T23:59:59.000Z

229

Microminiature coaxial cable and methods manufacture  

DOE Patents (OSTI)

A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 .mu.m thick and from 150 to 200 .mu.m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microballoons to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion.

Bongianni, Wayne L. (408 Colleen Ct., Los Alamos, NM 87544)

1986-01-01T23:59:59.000Z

230

Coaxial Cable Modeling and Verification.  

E-Print Network (OSTI)

??In this paper, analysis of coaxial cable is used to reveal how an electromagnetic wave propagates in an electrical conductor, and a new modeling language,… (more)

Shan, Zhengyu

2012-01-01T23:59:59.000Z

231

Holbrook Substation Superconductor Cable System, Long Island, New York Final Report  

SciTech Connect

The LIPA Superconductor project broke ground on July 4, 2006, was first energized on April 22, 2008 (Earth Day) and was commissioned on June 25, 2008. Since commissioning, up until early March, 2009, there were numerous refrigeration events that impacted steady state operations. This led to the review of the alarms that were being generated and a rewrite of the program logic in order to decrease the hypersensitivity surrounding these alarms. The high temperature superconductor (HTS) cable was energized on March 5, 2009 and ran uninterrupted until a human error during a refrigeration system switchover knocked the cable out of the grid in early February 2010. The HTS cable was in the grid uninterrupted from March 5, 2009 to February 4, 2010. Although there have been refrigeration events (propagated mainly by voltage sags/surges) during this period, the system was able to automatically switch over from the primary to the backup refrigeration system without issue as required during this period. On February 4, 2010, when switching from the backup over to the primary refrigeration system, two rather than one liquid nitrogen pumps were started inadvertently by a human error (communication) causing an overpressure in the cable cooling line. This in turn activated the pressure relief valve located in the grounding substation. The cable was automatically taken out of the grid without any damage to the components or system as a result of signals sent from the AMSC control cabinet to the LIPA substation. The cable was switched back into the grid again on March 16, 2010 without incident and has been operational since that time. Since switching from the backup to the primary is not an automatic process, a recent improvement was added to the refrigeration operating system to allow remote commands to return the system from backup to primary cooling. This improvement makes the switching procedure quicker since travel to the site to perform this operation is no longer necessary and safer since it is now a programmed procedure versus the former written procedure that was still subject to human variation in the process.

Maguire, James; McNamara, Joseph

2010-06-25T23:59:59.000Z

232

Optical voltage reference  

DOE Patents (OSTI)

An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

Rankin, R.; Kotter, D.

1994-04-26T23:59:59.000Z

233

HTS Cable Projects  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Superconductivity Superconductivity Partnerships with Industry ANL Air Liquide DOE Golden LANL AEP ORNL Nexans Niagara Mohawk Super Power American Superconductor NYSERDA BOC Praxair W ? tion systems. This is the most the nation. W superconductivity? HTS Cable Projects www.oe.energy.gov Phone: 202 \ 586-1411 Office of Electricity Delivery and Energy Reliability, OE-1 U.S. Department of Energy - 1000 Independence Avenue, SW - Washington, DC 20585. Plugging America Into the Future of Power "A National Effort to Introduce New Technology into

234

Experimental investigation of dielectric barrier discharge plasma actuators driven by repetitive high-voltage nanosecond pulses with dc or low frequency sinusoidal bias  

SciTech Connect

Experimental studies were conducted of a flow induced in an initially quiescent room air by a single asymmetric dielectric barrier discharge driven by voltage waveforms consisting of repetitive nanosecond high-voltage pulses superimposed on dc or alternating sinusoidal or square-wave bias voltage. To characterize the pulses and to optimize their matching to the plasma, a numerical code for short pulse calculations with an arbitrary impedance load was developed. A new approach for nonintrusive diagnostics of plasma actuator induced flows in quiescent gas was proposed, consisting of three elements coupled together: the schlieren technique, burst mode of plasma actuator operation, and two-dimensional numerical fluid modeling. The force and heating rate calculated by a plasma model was used as an input to two-dimensional viscous flow solver to predict the time-dependent dielectric barrier discharge induced flow field. This approach allowed us to restore the entire two-dimensional unsteady plasma induced flow pattern as well as characteristics of the plasma induced force. Both the experiments and computations showed the same vortex flow structures induced by the actuator. Parametric studies of the vortices at different bias voltages, pulse polarities, peak pulse voltages, and pulse repetition rates were conducted experimentally. The significance of charge buildup on the dielectric surface was demonstrated. The charge buildup decreases the effective electric field in the plasma and reduces the plasma actuator performance. The accumulated surface charge can be removed by switching the bias polarity, which leads to a newly proposed voltage waveform consisting of high-voltage nanosecond repetitive pulses superimposed on a high-voltage low frequency sinusoidal voltage. Advantages of the new voltage waveform were demonstrated experimentally.

Opaits, Dmitry F.; Likhanskii, Alexandre V.; Neretti, Gabriele; Zaidi, Sohail; Shneider, Mikhail N.; Miles, Richard B. [Mechanical and Aerospace Engineering, Princeton University, Princeton, New Jersey 08544 (United States); Macheret, Sergey O. [Lockheed Martin Aeronautics Company, Palmdale, California 93599 (United States)

2008-08-15T23:59:59.000Z

235

New Exchange-Area Cable  

Science Journals Connector (OSTI)

... describes an investigation carried out to determine whether the most economical series of new telephone cables would result from reductions in the diameters of ... would result from reductions in the diameters of cables having 24- and 26-gauge conductors, together with the addition of a ...

1942-06-20T23:59:59.000Z

236

Trans-Atlantic Telephone Cable  

Science Journals Connector (OSTI)

... and Telegraph Co. of Canada, for the provision of the first trans -Atlantic telephone cable, as distinct from the existing telegraph ... , as distinct from the existing telegraph cables. The installation, which is estimated to cost £12-J million, is likely to ...

1953-12-19T23:59:59.000Z

237

LIGHTNING PROTECTION OF BURIED CABLE  

Science Journals Connector (OSTI)

... FOR the new toll facilities now being installed in the United States, much of the cable is laid underground to secure greater immunity from effects of sleet, snow, and storms ... underground to secure greater immunity from effects of sleet, snow, and storms. Burying the cable alone is not necessarily sufficient to free it from the effects of lightning damage. ...

1943-10-09T23:59:59.000Z

238

Recommended practice for fire protection for electric generating plants and high voltage direct current converter stations. 2005 ed.  

SciTech Connect

The standard outlines fire safety recommendations for gas, oil, coal, and alternative fuel electric generating plants including high voltage direct current converter stations and combustion turbine units greater than 7500 hp used for electric generation. Provisions apply to both new and existing plants. The document provides fire prevention and fire protection recommendations for the: safety of construction and operating personnel; physical integrity of plant components; and continuity of plant operations. The 2005 edition includes revisions and new art that clarify existing provisions. 5 annexes.

NONE

2005-07-01T23:59:59.000Z

239

Photonic-powered cable assembly  

DOE Patents (OSTI)

A photonic-cable assembly includes a power source cable connector ("PSCC") coupled to a power receive cable connector ("PRCC") via a fiber cable. The PSCC electrically connects to a first electronic device and houses a photonic power source and an optical data transmitter. The fiber cable includes an optical transmit data path coupled to the optical data transmitter, an optical power path coupled to the photonic power source, and an optical feedback path coupled to provide feedback control to the photonic power source. The PRCC electrically connects to a second electronic device and houses an optical data receiver coupled to the optical transmit data path, a feedback controller coupled to the optical feedback path to control the photonic power source, and a photonic power converter coupled to the optical power path to convert photonic energy received over the optical power path to electrical energy to power components of the PRCC.

Sanderson, Stephen N.; Appel, Titus James; Wrye, IV, Walter C.

2013-01-22T23:59:59.000Z

240

Photonic-powered cable assembly  

DOE Patents (OSTI)

A photonic-cable assembly includes a power source cable connector ("PSCC") coupled to a power receive cable connector ("PRCC") via a fiber cable. The PSCC electrically connects to a first electronic device and houses a photonic power source and an optical data transmitter. The fiber cable includes an optical transmit data path coupled to the optical data transmitter, an optical power path coupled to the photonic power source, and an optical feedback path coupled to provide feedback control to the photonic power source. The PRCC electrically connects to a second electronic device and houses an optical data receiver coupled to the optical transmit data path, a feedback controller coupled to the optical feedback path to control the photonic power source, and a photonic power converter coupled to the optical power path to convert photonic energy received over the optical power path to electrical energy to power components of the PRCC.

Sanderson, Stephen N; Appel, Titus James; Wrye, IV, Walter C

2014-06-24T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Design and PHILS-based Transient Analysis of a Tri-axial HTS Power Cable  

Science Journals Connector (OSTI)

Abstract Tri-axial high-temperature superconducting (HTS) power cables are very efficient compared with other HTS power cables due to their reduced use of HTS wires and cryogenic surface area, resulting from the mutually layered structure of the three phases. However, the operating characteristics of tri-axial HTS power cables differ from other cables in a transient-state condition. In order to install HTS power cables in a real grid, feasibility verification through simulation or experimentation is required in advance. Thus, the authors design a tri-axial HTS power cable and implement a power hardware-in-the-loop simulation that consists of a real time digital simulator-based simulation model and hardware devices including a power supply and a 1 m-long tri-axial HTS model cable. Simulation results show the stability verification under steady-state and transient-state conditions.

Sun-Kyoung Ha; Chang-Soon Kim; Sung-Kyu Kim; Minh-Chau Dinh; Jin-Geun Kim; Minwon Park; In-Keun Yu; Sangjin Lee; Kideok Sim

2014-01-01T23:59:59.000Z

242

Low Beam Voltage, 10 MW, L-Band Cluster Klystron  

SciTech Connect

Conceptual design of a multi-beam klystron (MBK) for possible ILC and Project X applications is presented. The chief distinction between this MBK design and existing 10-MW MBK's is the low operating voltage of 60 kV. There are at least four compelling reasons that justify development at this time of a low-voltage MBK, namely (1) no pulse transformer; (2) no oil tank for high-voltage components and for the tube socket; (3) no high-voltage cables; and (4) modulator would be a compact 60-kV IGBT switching circuit. The proposed klystron consists of four clusters containing six beams each. The tube has common input and output cavities for all 24 beams, and individual gain cavities for each cluster. A closely related optional configuration, also for a 10 MW tube, would involve four totally independent cavity clusters with four independent input cavities and four 2.5 MW output ports, all within a common magnetic circuit. This option has appeal because the output waveguides would not require a controlled atmosphere, and because it would be easier to achieve phase and amplitude stability as required in individual SC accelerator cavities.

Teryaev, V.; /Novosibirsk, IYF; Yakovlev, V.P.; /Fermilab; Kazakov, S.; /KEK, Tsukuba; Hirshfield, J.L.; /Yale U. /Omega-P, New Haven

2009-05-01T23:59:59.000Z

243

A high-stability scanning tunneling microscope achieved by an isolated tiny scanner with low voltage imaging capability  

SciTech Connect

We present a novel homebuilt scanning tunneling microscope (STM) with high quality atomic resolution. It is equipped with a small but powerful GeckoDrive piezoelectric motor which drives a miniature and detachable scanning part to implement coarse approach. The scanning part is a tiny piezoelectric tube scanner (industry type: PZT-8, whose d{sub 31} coefficient is one of the lowest) housed in a slightly bigger polished sapphire tube, which is riding on and spring clamped against the knife edges of a tungsten slot. The STM so constructed shows low back-lashing and drifting and high repeatability and immunity to external vibrations. These are confirmed by its low imaging voltages, low distortions in the spiral scanned images, and high atomic resolution quality even when the STM is placed on the ground of the fifth floor without any external or internal vibration isolation devices.

Wang, Qi; Wang, Junting; Lu, Qingyou, E-mail: qxl@ustc.edu.cn [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China) [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China); Hefei National Laboratory for Physical Sciences at Microscale, University of Science and Technology of China, Hefei, Anhui 230026 (China); Hou, Yubin [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China)] [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China)

2013-11-15T23:59:59.000Z

244

The effect of technology on cable service to large, networked communities  

E-Print Network (OSTI)

Delivering cable television to college and university campuses is maintained by a highly specialized industry which involves significant technological and logistical challenges. As campuses continue to contribute financial ...

Harmeling, Paul K. (Paul Kristoffer), 1975-

2003-01-01T23:59:59.000Z

245

Improving the performance of stainless-steel DC high voltage photoelectron gun cathode electrodes via gas conditioning with helium or krypton  

SciTech Connect

Gas conditioning was shown to eliminate field emission from cathode electrodes used inside DC high voltage photoelectron guns, thus providing a reliable means to operate photoguns at higher voltages and field strengths. Measurements and simulation results indicate that gas conditioning eliminates field emission from cathode electrodes via two mechanisms: sputtering and implantation, with the benefits of implantation reversed by heating the electrode. We have studied five stainless steel electrodes (304L and 316LN) that were polished to approximately 20 nm surface roughness using diamond grit, and evaluated inside a high voltage apparatus to determine the onset of field emission as a function of voltage and field strength. The field emission characteristics of each electrode varied significantly upon the initial application of voltage but improved to nearly the same level after gas conditioning using either helium or krypton, exhibiting less than 10 pA field emission at ?225 kV bias voltage with a 50 mm cathode/anode gap, corresponding to a field strength of ~13 MV/m. Field emission could be reduced with either gas, but there were conditions related to gas choice, voltage and field strength that were more favorable than others.

Bastaninejad, Mahzad [ODU; Elmustafa, Abdelmageed [ODU; Forman, Eric I. [JLAB; Clark, James [JLAB; Covert, Steven R. [JLAB; Grames, Joseph M. [JLAB; Hansknecht, John C. [JLAB; Hernandez-Garcia, Carlos [JLAB; Poelker, Bernard [JLAB; Suleiman, Riad S. [JLAB

2014-10-01T23:59:59.000Z

246

Assessment of occupational exposure to magnetic fields in high-voltage substations (154/34.5 kV)  

Science Journals Connector (OSTI)

......workers on lines and cables and 0.2-18.48 microT for electricians(1,2). At the moment, it can be mentioned that ICNIRP...H., Iskender M. F. Radio Frequency Radiation Dosimetry Handbook. (1986) fourth edn. TX: Brooks Air Force Base, School......

S. Helhel; S. Ozen

2008-03-01T23:59:59.000Z

247

Peak Power Bi-directional Transfer From High Speed Flywheel to Electrical Regulated Bus Voltage System  

E-Print Network (OSTI)

were performed to determine the energy transfer capabilities of a flywheel coupled high speed permanent magnet synchronous machine through the proposed system's energy storage tank. Results are presented

Szabados, Barna

248

ANUEADflM-31 Electric Power High-Voltage Transmission Lines:  

Office of Scientific and Technical Information (OSTI)

formulated fluid that is kept under high pressure. This fluid helps to dissipate the power loss heat generated by the conductors. The construction costs in 1991 dollars for...

249

Acceleration Factors for Damp-Heat and HAST with High Voltage...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High PID Resistant Cross-Linked Encapsulnt Based on Polyolefin SOLAR ASCE Comparing Accelerated Testing and Outdoor Exposure Agenda for the PV Module Reliability Workshop,...

250

Cable Damage Detection System and Algorithms Using Time Domain Reflectometry  

SciTech Connect

This report describes the hardware system and the set of algorithms we have developed for detecting damage in cables for the Advanced Development and Process Technologies (ADAPT) Program. This program is part of the W80 Life Extension Program (LEP). The system could be generalized for application to other systems in the future. Critical cables can undergo various types of damage (e.g. short circuits, open circuits, punctures, compression) that manifest as changes in the dielectric/impedance properties of the cables. For our specific problem, only one end of the cable is accessible, and no exemplars of actual damage are available. This work addresses the detection of dielectric/impedance anomalies in transient time domain reflectometry (TDR) measurements on the cables. The approach is to interrogate the cable using time domain reflectometry (TDR) techniques, in which a known pulse is inserted into the cable, and reflections from the cable are measured. The key operating principle is that any important cable damage will manifest itself as an electrical impedance discontinuity that can be measured in the TDR response signal. Machine learning classification algorithms are effectively eliminated from consideration, because only a small number of cables is available for testing; so a sufficient sample size is not attainable. Nonetheless, a key requirement is to achieve very high probability of detection and very low probability of false alarm. The approach is to compare TDR signals from possibly damaged cables to signals or an empirical model derived from reference cables that are known to be undamaged. This requires that the TDR signals are reasonably repeatable from test to test on the same cable, and from cable to cable. Empirical studies show that the repeatability issue is the 'long pole in the tent' for damage detection, because it is has been difficult to achieve reasonable repeatability. This one factor dominated the project. The two-step model-based approach is summarized as follows: Step 1, Cable Modeling: Given input-output TDR signals s(n) and x{sub U}(n) for a cable known to be free of damage, system identification algorithms are used to compute a dynamic prediction-error cable model that has output {cflx x}{sub U}(n). The model is declared valid when the innovations e{sub U}(n) = x{sub U}(n) {cflx x}{sub U}(n) satisfy a statistical zero-mean whiteness test. This validated model output is then used as a known reference to which other cables can be compared. Step 2, Cable Testing: The TDR output signal x{sub D}(n) from a cable under test is compared with the model output {cflx x}{sub U}(n) by computing the innovations e{sub D}(n) = x{sub D}(n) {cflx x}{sub U}(n). The innovations are tested using a short-term whiteness test statistic, which employs a statistical confidence interval. If the cable passes the test, this implies that the model is valid and the cable is declared undamaged. If the cable fails the test, this indicates a model mismatch, which means that the cable's dielectric properties have changed; and this implies that the cable is damaged. The test threshold is adjusted to maximize probability of detection and minimize probability of false alarm according to an empirically determined receiver operating characteristic (ROC) curve. An associated confidence interval on the probability of correct classification is also provided. The effectiveness of the algorithm is demonstrated using measured TDR signals for undamaged and damaged cables. Experimental and algorithmic methods for coping with repeatability issues are presented. The model-based damage detection algorithms have been shown to perform well for some representative examples of real TDR signals acquired using the two-dimensional (2D) mockup fixture. If the damage causes a short circuit, then damage detection performance is generally good to excellent. Examples include the cases demonstrated in this report for cuts and pinholes. If the damage does not cause a short circuit, then damage detection performance is generally poor to fair. Examples include

Clark, G A; Robbins, C L; Wade, K A; Souza, P R

2009-03-24T23:59:59.000Z

251

HVDC submarine power cables systems state of the art and future developments  

SciTech Connect

The paper begins with an introduction on the reasons that lead to the use of HVDC submarine cable links. The main aspects for the choice of direct current are presented as well as the advantages deriving from the utilization of submarine cables. The second part is dedicated to a discussion on the various type of insulation that could be used in power cables and their possible application to HVDC submarine cables. In the following there is a description of the main characteristics and technical details of some particular project that at present time (1995) are in progress. Two projects are briefly presented: Spain-Morocco, a 26 km long interconnection for the transmission, in a first phase, of 700 MW from Spain to Morocco at 400 kV a.c. by means of three cables, plus one spare, of the fluid filled type. The cables are designed for a future change to d.c. 450 kV, allowing a transmission of 500 MW each (i.e., 2 GW total). One of the peculiarities of the link is the maximum water depth of 615 m (world record for submarine power cables at the time of installation). Italy-Greece, a 1km long interconnection for the transmission of 500 MW (bi-directional) by means of one paper insulated mass impregnated cable having 1,250 sq mm conductor size and insulated for a rated voltage of 400 kV. This link (the installation of which will be posterior to the Spain-Morocco) will attain the world record for the maximum water depth for submarine power cables: 1,000 m. The last part deals with the future developments expected in this field, in terms of conductor size and voltage, that means an increase in transmissible capacity.

Valenza, D.; Cipollini, G. [Pirelli Cavi S.p.A., Milano (Italy)

1995-12-31T23:59:59.000Z

252

A High-Frequency Resonant Inverter Topology With Low-Voltage Stress  

E-Print Network (OSTI)

This paper presents a new switched-mode resonant inverter, which we term the inverter, that is well suited to operation at very high frequencies and to rapid on/off control. Features of this inverter topology include low ...

Rivas, Juan M.

253

Tetrapropyl-tetraphenyl-diindenoperylene derivative as a green absorber for high-voltage stable organic solar cells  

Science Journals Connector (OSTI)

We present small molecule organic solar cells (SMOSC) based on flat heterojunctions (FHJ) of the alternative green donor 2,3,10,11-tetrapropyl-1,4,9,12-tetraphenyl-diindeno[1,2,3-cd:1’,2’,3’-lm]perylene (P4-Ph4-DIP) and the fullerene C60. P4-Ph4-DIP absorbs in the green spectral range and thus fills the spectral gap that standard absorber materials (zinc or copper phthalocyanine for red and C60 for blue absorption) leave, thus allowing broad coverage of the sun spectrum, which is of major interest for tandem devices. The materials properties of P4-Ph4-DIP are studied, and SMOSC are characterized by current voltage, external quantum efficiency, and aging measurements. The solar cells display very high fill factors FF > 76% and open circuit voltages VOC of close to 1 V. Mismatch-corrected efficiencies of up to 1.9% are obtained. Aging measurements show that C60 in conjunction with P4-Ph4-DIP yields extremely stable devices. We observe ? 88% of the initial efficiency after 2500 h illumination at 999 mW/cm2 illumination intensity, with no observable change in short-circuit current density. Furthermore, we also show that a systematic variation of donor thickness in FHJ can be combined with transfer matrix formalism-based optical simulations and the continuity equation for excitons to reliably determine the exciton diffusion length LD. A value of 9 ± 1 nm is found for P4-Ph4-DIP.

Jan Meiss; Martin Hermenau; Wolfgang Tress; Christoph Schuenemann; Franz Selzer; Markus Hummert; Joerg Alex; Gerhard Lackner; Karl Leo; Moritz Riede

2011-04-11T23:59:59.000Z

254

Epidemiologic study of Holstein dairy cow performance and reproduction near a high-voltage direct - current powerline  

SciTech Connect

The development and operation of a high-voltage direct-current (HVDC) transmission line in rural Minnesota generated public concern over potential adverse effects to nearby residents and their livestock. Electrical parameters near an HVDC line decline rapidly with distance, but effects on ambient space charge have been detected out to 1 mile. To identify potential adverse effects of HVDC line operation on livestock, case-control and cohort study methods were used to examine various indices of Holstein performance in relation to distance from the line and the onset of line operation. It was believed that these indices would reflect changes in physiologic function or overt health effects that might arise from the HVDC environment. High-quality performance data from existing Dairy Herd Improvement Association (DHIA) records were obtained for 97% of qualifying herds located within 10 miles of the line. The large number of animals and years of observation provided high statistical power to detect even small systematic changes in performance. No significant differences in milk production or reproductive capacity were associated with presumed exposure to the HVDC environment. The absence of measurable effects in a large sentinel animal population may have implications for the assessment of human health risks related to HVDC transmission lines.

Martin, F.B.; Bender, A.; Steuernagel, G.; Robinson, R.A.; Revsbech, R.; Sorensen, D.K.; Williamson, N.; Williams, A.

1986-01-01T23:59:59.000Z

255

Reduction of interference on substation low voltage wiring  

SciTech Connect

This paper describes test results and mitigation methods of electromagnetic interference (EMI) on control and low voltage circuits in substations caused by air disconnect switch operation. The tests are focused on a comparison between unshielded and shielded circuits from capacitively coupled voltage transformers (CCVT) and other equipment circuits in the vicinity. New test data are presented comparing unshielded and shielded cables and transient currents on all connections to the CCVT including the pedestal and ground strap. The paper gives a practical and understandable explanation of the causes of EMI in substations and how shielded cable and parallel ground conductors reduce interference. Design guidelines are listed in the Conclusion.

Gavazza, R.J. [Pacific Gas and Electric Co., San Francisco, CA (United States)] [Pacific Gas and Electric Co., San Francisco, CA (United States); Wiggins, C.M. [Carl M. Wiggins and Associates, Friendswood, TX (United States)] [Carl M. Wiggins and Associates, Friendswood, TX (United States)

1996-07-01T23:59:59.000Z

256

Charge-pump voltage converter  

DOE Patents (OSTI)

A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

Brainard, John P. (Albuquerque, NM); Christenson, Todd R. (Albuquerque, NM)

2009-11-03T23:59:59.000Z

257

A Laves phase-body-centered cubic structural relationship determined using high voltage electron microscopy  

SciTech Connect

High energy electron and ion irradiation of a TiCr{sub 2} Laves compound were found previously to result in a transformation to a body-centered cubic (bcc) solid solution. In the case of electron irradiation, the precipitating bcc phase exhibits preferential crystallographic orientation with respect to the initial compound crystal for irradiation temperatures above 200 K. This article presents an analysis of the electron diffraction data gathered in the course of the electron irradiation-induced Laves phase to bcc transformation in TiCr{sub 2}. A structural relationship between the bcc and Laves compound crystal lattices is determined which can account for all observations of preferentially oriented bcc precipitates. The significance of this mechanism for transformations between bcc and the Laves phases is discussed. In addition, the possible significance for deformation mechanisms of the Laves compounds is explored.

Sinkler, W. [GKSS Forschungszentrum, Geesthacht (Germany). Inst. fuer Werkstofforschung] [GKSS Forschungszentrum, Geesthacht (Germany). Inst. fuer Werkstofforschung

1996-04-01T23:59:59.000Z

258

A High -Temperature, High-Voltage, Fast Response Time Linear Regulator in 0.8um BCD-on-SOI.  

E-Print Network (OSTI)

??The sale of hybrid electric vehicles (HEVs) has increased tenfold from the year 2001 to 2009 [1]. With this the demand for high temperature electronics… (more)

Su, Chia Hung

2010-01-01T23:59:59.000Z

259

Use of Shape Memory Alloys damper device to mitigate vibration amplitudes of bridge cables  

Science Journals Connector (OSTI)

Abstract Most of civil engineering cable structures are subjected to potential damages mainly due to dynamic oscillations induced by wind, rain or traffic. If vibration amplitudes of bridge cables are too high, it may cause fatigue damages. Recently, research had been conducted dealing with the use of damping devices in order to reduce vibration amplitudes of cables. In this paper, thin Ni–Ti (Nickel–Titanium) Shape Memory Alloy (SMA) wires were used as damping devices. The aim of this work is to qualitatively and quantitatively assess the efficiency of Ni–Ti dampers to reduce the vibration amplitudes of civil engineering cables. For a practical control of the SMA in damping for stayed cables, several measurements were carried out in this work, on a realistic full scale cable sample in Ifsttar (Nantes – France) laboratory facility. The experimental observations were done inducing quite high oscillations in the middle of the cable without any damper device or with a SMA damper device made by two thin NiTi parallel wires. The intrinsic damping coefficient in the free cable was extremely low. The reduction of cable oscillation amplitudes was about 25% in 1 min. The effects of the damper are investigated in this study, outlining the drastic reduction of the oscillation amplitudes all along the cable in less than 10 s. Other tests were performed placing the source of oscillations or the damper at different positions along the cable and the results are observed and compared. Finite element simulations have been carried out using Marc/Mentat finite element code with good agreement between experiment and simulation. The finite element tools enable to study quantitatively the effectiveness of the damper at several points of the cable.

Lamine Dieng; Guillaume Helbert; Shabnam Arbab Chirani; Thibaut Lecompte; Philippe Pilvin

2013-01-01T23:59:59.000Z

260

Back-to-Back Energization of a 60kV Cable Network -Inrush Currents Phenomenon  

E-Print Network (OSTI)

transmission lines with a rated voltage equal to and below 150kV must be put underground, in order to reduce's energization. Fig. 1. ENV 60kV Network map Fig. 2. Single Line Diagram of the analyzed area The knowledge1 Back-to-Back Energization of a 60kV Cable Network - Inrush Currents Phenomenon F. Faria da Silva

Silva, Filipe Faria Da

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Ames Lab 101: Reinventing the Power Cable  

ScienceCinema (OSTI)

Ames Laboratory researchers are working to develop new electrical power cables that are stronger and lighter than the cables currently used in the nation's power grid. Nano Tube animation by Iain Goodyear

Russell, Alan

2014-06-04T23:59:59.000Z

262

Ames Lab 101: Reinventing the Power Cable  

SciTech Connect

Ames Laboratory researchers are working to develop new electrical power cables that are stronger and lighter than the cables currently used in the nation's power grid. Nano Tube animation by Iain Goodyear

Russell, Alan

2013-09-27T23:59:59.000Z

263

Darwin Magazine Puzzle The Transatlantic Cable  

E-Print Network (OSTI)

Darwin Magazine Puzzle The Transatlantic Cable by Groucho March 14, 2008 A transatlantic cable of transatlantic trips you need to make, and how do you do it? As an illustration, if the number of wires were just

MacKay, David J.C.

264

New Australia-Tasmania Submarine Cable  

Science Journals Connector (OSTI)

... THE new submarine cable which was successfully laid across the Bass Strait last November marks a notable advance in ... across the Bass Strait last November marks a notable advance in the technique of submarine cable transmission. Before laying this ...

1936-03-14T23:59:59.000Z

265

The Belfast-Stranraer Telephone Cable  

Science Journals Connector (OSTI)

... IN 1853, the British and Irish Magnetic Telegraph Company laid a cable between Port Patrick and Donaghadee. This ... between Port Patrick and Donaghadee. This cable proved to be successful and was one of the forerunners of the Atlantic ...

1938-06-11T23:59:59.000Z

266

Low Voltage High-SNR Pipeline Data Converters Charles Myers, Jipeng Li, Dong-Young Chang, and Un-Ku Moon  

E-Print Network (OSTI)

Low Voltage High-SNR Pipeline Data Converters Charles Myers, Jipeng Li, Dong-Young Chang, and Un pipeline data converter. This is accomplished with the removal of the S/H input stage and the use of a rail limitations. In pipeline data converters, noise reduction options such as oversampling and noise shaping

Moon, Un-Ku

267

“Quantum Coaxial Cables” for Solar Energy Harvesting  

Science Journals Connector (OSTI)

“Quantum Coaxial Cables” for Solar Energy Harvesting ... A conventional coaxial cable is a two-conductor cable consisting of a central wire conductor symmetrically surrounded by a braided conductor with an insulating spacer in between, as shown in Figure 1a. ...

Yong Zhang; Lin-Wang Wang; Angelo Mascarenhas

2007-04-05T23:59:59.000Z

268

Effect of the change in the load resistance on the high voltage pulse transformer of the intense electron-beam accelerators  

SciTech Connect

A high voltage pulse transformer (HVPT) is usually used as a charging device for the pulse forming line (PFL) of intense electron-beam accelerators (IEBAs). Insulation of the HVPT is one of the important factors that restrict the development of the HVPT. Until now, considerable effort has been focused on minimizing high field regions to avoid insulation breakdown between windings. Characteristics of the HVPT have been widely discussed to achieve these goals, but the effects of the PFL and load resistance on HVPT are usually neglected. In this paper, a HVPT is used as a charging device for the PFL of an IEBA and the effect of the change in the load resistance on the HVPT of the IEBA is presented. When the load resistance does not match the wave impedance of the PFL, a high-frequency bipolar oscillating voltage will occur, and the amplitude of the oscillating voltage will increase with the decrease in the load resistance. The load resistance approximates to zero and the amplitude of the oscillating voltage is much higher. This makes it easier for surface flashover along the insulation materials to form and decrease the lifetime of the HVPT.

Cheng Xinbing; Liu Jinliang; Qian Baoliang; Zhang Yu; Zhang Hongbo [College of Photoelectrical Science and Engineering, National University of Defense Technology, Hunan 410073 (China)

2009-11-15T23:59:59.000Z

269

Low-voltage gyrotrons  

SciTech Connect

For a long time, the gyrotrons were primarily developed for electron cyclotron heating and current drive of plasmas in controlled fusion reactors where a multi-megawatt, quasi-continuous millimeter-wave power is required. In addition to this important application, there are other applications (and their number increases with time) which do not require a very high power level, but such issues as the ability to operate at low voltages and have compact devices are very important. For example, gyrotrons are of interest for a dynamic nuclear polarization, which improves the sensitivity of the nuclear magnetic resonance spectroscopy. In this paper, some issues important for operation of gyrotrons driven by low-voltage electron beams are analyzed. An emphasis is made on the efficiency of low-voltage gyrotron operation at the fundamental and higher cyclotron harmonics. These efficiencies calculated with the account for ohmic losses were, first, determined in the framework of the generalized gyrotron theory based on the cold-cavity approximation. Then, more accurate, self-consistent calculations for the fundamental and second harmonic low-voltage sub-THz gyrotron designs were carried out. Results of these calculations are presented and discussed. It is shown that operation of the fundamental and second harmonic gyrotrons with noticeable efficiencies is possible even at voltages as low as 5-10 kV. Even the third harmonic gyrotrons can operate at voltages about 15 kV, albeit with rather low efficiency (1%-2% in the submillimeter wavelength region).

Glyavin, M. Yu.; Zavolskiy, N. A.; Sedov, A. S. [Institute of Applied Physics RAS, N. Novgorod 603600 (Russian Federation); Nusinovich, G. S. [IREAP, University of Maryland, College Park, Maryland 20742-3511 (United States)

2013-03-15T23:59:59.000Z

270

A wide bandgap silicon carbide (SiC) gate driver for high-temperature and high-voltage applications  

SciTech Connect

Limitations of silicon (Si) based power electronic devices can be overcome with Silicon Carbide (SiC) because of its remarkable material properties. SiC is a wide bandgap semiconductor material with larger bandgap, lower leakage currents, higher breakdown electric field, and higher thermal conductivity, which promotes higher switching frequencies for high power applications, higher temperature operation, and results in higher power density devices relative to Si [1]. The proposed work is focused on design of a SiC gate driver to drive a SiC power MOSFET, on a Cree SiC process, with rise/fall times (less than 100 ns) suitable for 500 kHz to 1 MHz switching frequency applications. A process optimized gate driver topology design which is significantly different from generic Si circuit design is proposed. The ultimate goal of the project is to integrate this gate driver into a Toyota Prius plug-in hybrid electric vehicle (PHEV) charger module. The application of this high frequency charger will result in lighter, smaller, cheaper, and a more efficient power electronics system.

Lamichhane, Ranjan [University of Arkansas; Ericson, Milton Nance [ORNL; Frank, Steven Shane [ORNL; BRITTONJr., CHARLES L. [Oak Ridge National Laboratory (ORNL); Marlino, Laura D [ORNL; Mantooth, Alan [University of Arkansas; Francis, Matt [APEI, Inc.; Shepherd, Dr. Paul [University of Arkansas; Glover, Dr. Michael [University of Arkansas; Podar, Mircea [ORNL; Perez, M [University of Arkansas; Mcnutt, Tyler [APEI, Inc.; Whitaker, Mr. Bret [APEI, Inc.; Cole, Mr. Zach [APEI, Inc.

2014-01-01T23:59:59.000Z

271

Abstract #2266: Cables 1 knockdown in immortalized human ovarian surface epithelial cells results in their uptake of more malignant like characteristics  

Science Journals Connector (OSTI)

...2009; Denver, CO Abstract #2266: Cables 1 knockdown in immortalized human ovarian...Meeting-- Apr 18-22, 2009; Denver, CO Cables 1 is best known as a cyclin-dependent...Previously we reported that loss of Cables 1 expression was observed with high frequency...

Hideo Sakamoto; Anne Friel; Lawrence Zukerberg; Ronny Drapkin; Bo Rueda

2009-05-01T23:59:59.000Z

272

NORTHWESTERN UNIVERSITY Finite Element Analysis of TDR Cable-Grout-Soil Mass  

E-Print Network (OSTI)

NORTHWESTERN UNIVERSITY Finite Element Analysis of TDR Cable-Grout-Soil Mass Interaction During Cable Shear Test.................................................................................................................... 9 Cable Types

273

Magnetic instabilities in Nb3Sn strands and cables  

SciTech Connect

This paper describes a model for calculation of magnetic instabilities in superconducting wires with transport current and reports results of instability simulations in Nb{sub 3}Sn strands from different manufactures. The effect of magnetic instabilities on the strand and cable performance is presented and a criterion for the maximum effective sub-element size of strands for high field magnets is formulated.

Kashikhim, Vadim V.; Zlobin, Alexander V.; /Fermilab

2004-11-01T23:59:59.000Z

274

Researchers map atomic movements that trigger voltage fade in...  

NLE Websites -- All DOE Office Websites (Extended Search)

map atomic movements that trigger voltage fade in high-energy-density batteries January 22, 2015 Voltage and capacity curves from an LMR-NMC high-energy cathode show voltage fade...

275

Field Demonstration of a 24-kV Superconducting Cable at Detroit Edison  

SciTech Connect

Customer acceptance of high temperature superconducting (HTS) cable technology requires a substantial field demonstration illustrating both the system's technical capabilities and its suitability for installation and operation within the utility environment. In this project, the world's first underground installation of an HTS cable using existing ductwork, a 120 meter demonstration cable circuit was designed and installed between the 24 kV bus distribution bus and a 120 kV-24 kV transformer at Detroit Edison's Frisbie substation. The system incorporated cables, accessories, a refrigeration system, and control instrumentation. Although the system was never put in operation because of problems with leaks in the cryostat, the project significantly advanced the state-of-the-art in the design and implementation of Warm Dielectric cable systems in substation applications. Lessons learned in this project are already being incorporated in several ongoing demonstration projects.

Kelley, Nathan; Corsaro, Pietro

2004-12-01T23:59:59.000Z

276

Voltage controlled current source  

DOE Patents (OSTI)

A seven decade, voltage controlled current source is described for use in testing intermediate range nuclear instruments that covers the entire test current range of from 10 picoamperes to 100 microamperes. High accuracy is obtained throughout the entire seven decades of output current with circuitry that includes a coordinated switching scheme responsive to the input signal from a hybrid computer to control the input voltage to an antilog amplifier, and to selectively connect a resistance to the antilog amplifier output to provide a continuous output current source as a function of a preset range of input voltage. An operator controlled switch provides current adjustment for operation in either a real-time simulation test mode or a time response test mode.

Casne, Gregory M. (Pittsburgh, PA)

1992-01-01T23:59:59.000Z

277

Identifying surface structural changes in layered Li-excess nickel manganese oxides in high voltage lithium ion batteries: A joint experimental and theoretical study  

SciTech Connect

High voltage cathode materials Li-excess layered oxide compounds Li[Ni{sub x}Li{sub 1/3-2x/3}Mn{sub 2/3-x/3}]O{sub 2} (0 < x < 1/2) are investigated in a joint study combining both computational and experimental methods. The bulk and surface structures of pristine and cycled samples of Li[Ni{sub 1/5}Li{sub 1/5}Mn{sub 3/5}]O{sub 2} are characterized by synchrotron X-Ray diffraction together with aberration corrected Scanning Transmission Electron Microscopy (a-S/TEM). Electron Energy Loss Spectroscopy (EELS) is carried out to investigate the surface changes of the samples before/after electrochemical cycling. Combining first principles computational investigation with our experimental observations, a detailed lithium de-intercalation mechanism is proposed for this family of Li-excess layered oxides. The most striking characteristics in these high voltage high energy density cathode materials are (1) formation of tetrahedral lithium ions at voltage less than 4.45 V and (2) the transition metal (TM) ions migration leading to phase transformation on the surface of the materials. We show clear evidence of a new spinel-like solid phase formed on the surface of the electrode materials after high-voltage cycling. It is proposed that such surface phase transformation is one of the factors contributing to the first cycle irreversible capacity and the main reason for the intrinsic poor rate capability of these materials.

Xu, Bo; Fell, Christopher R.; Chi, Miaofang; Meng, Ying Shirley (ORNL); (Florida); (UCSD)

2011-09-06T23:59:59.000Z

278

A PC-PCL-based control system for the high-voltage pulsed-power operation of the Intense Diagnostic Neutral Beam (IDNB) Experiment  

SciTech Connect

A stand-alone, semiautomated control system for the high-voltage pulsed-power energy sources on the Intense Diagnostic Neutral Beam Experiment at Los Alamos National Laboratory using personal computer (PC) and programmable logic controller (PLC) technology has been developed and implemented. The control system, consisting of a PC with the graphic operator interface, the network connecting the PC to the PLC, the PLC, the PLC I/O modules, fiber-optic interfaces and software, is described.

Gribble, R.

1993-06-01T23:59:59.000Z

279

Voltage balanced multilevel voltage source converter system  

DOE Patents (OSTI)

A voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means.

Peng, Fang Zheng (Oak Ridge, TN); Lai, Jih-Sheng (Knoxville, TN)

1997-01-01T23:59:59.000Z

280

Voltage balanced multilevel voltage source converter system  

DOE Patents (OSTI)

Disclosed is a voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means. 15 figs.

Peng, F.Z.; Lai, J.S.

1997-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Prestress Losses in the Stabilizing Cables of a Composite Saddle-Shaped Cable Roof  

Science Journals Connector (OSTI)

The paper deals with a square composite saddle-shaped cable roof 30 × 30 m in the plan, which is formed by two orthogonal cable groups joined with a compliant support contour. ... of the roof is achieved by prest...

D. Serdjuks; K. Rocens; L. Pakrastinsh

2003-07-01T23:59:59.000Z

282

Silicon-on-insulator-based high-voltage, high-temperature integrated circuit gate driver for silicon carbide-based power field effect transistors  

SciTech Connect

Silicon carbide (SiC)-based field effect transistors (FETs) are gaining popularity as switching elements in power electronic circuits designed for high-temperature environments like hybrid electric vehicle, aircraft, well logging, geothermal power generation etc. Like any other power switches, SiC-based power devices also need gate driver circuits to interface them with the logic units. The placement of the gate driver circuit next to the power switch is optimal for minimising system complexity. Successful operation of the gate driver circuit in a harsh environment, especially with minimal or no heat sink and without liquid cooling, can increase the power-to-volume ratio as well as the power-to-weight ratio for power conversion modules such as a DC-DC converter, inverter etc. A silicon-on-insulator (SOI)-based high-voltage, high-temperature integrated circuit (IC) gate driver for SiC power FETs has been designed and fabricated using a commercially available 0.8--m, 2-poly and 3-metal bipolar-complementary metal oxide semiconductor (CMOS)-double diffused metal oxide semiconductor (DMOS) process. The prototype circuit-s maximum gate drive supply can be 40-V with peak 2.3-A sourcing/sinking current driving capability. Owing to the wide driving range, this gate driver IC can be used to drive a wide variety of SiC FET switches (both normally OFF metal oxide semiconductor field effect transistor (MOSFET) and normally ON junction field effect transistor (JFET)). The switching frequency is 20-kHz and the duty cycle can be varied from 0 to 100-. The circuit has been successfully tested with SiC power MOSFETs and JFETs without any heat sink and cooling mechanism. During these tests, SiC switches were kept at room temperature and ambient temperature of the driver circuit was increased to 200-C. The circuit underwent numerous temperature cycles with negligible performance degradation.

Tolbert, Leon M [ORNL; Huque, Mohammad A [ORNL; Blalock, Benjamin J [ORNL; Islam, Syed K [ORNL

2010-01-01T23:59:59.000Z

283

Integrated polymer solar cells in serial architecture with patterned charge-transporting MoOx for miniature high-voltage sources  

Science Journals Connector (OSTI)

We develop miniature high-voltage sources from polymer solar cells (PSCs) with charge-transporting molybdenum oxide (MoOx) integrated in a serial architecture through sacrificial layer (SL)-assisted patterning. The MoOx layer, being patterned by the lift-off process of the SL of a hydrophobic fluorinated-polymer, as a hole transporting layer plays a critical role on the reduction of the dark current and the increase of a high open circuit voltage of an integrated PSC array. The underlying mechanism lies primarily on the elimination of the lateral charge pathways in the MoOx layer in the presence of the electrode interconnection. Two miniature voltage sources consisting of 20 PSCs and 50 PSCs are demonstrated in the operation of a liquid crystal display and an organic field-effect transistor, respectively. Our SL-assisted integration approach will be directly applicable for implementing the self-power sources made of the PSCs into a wide range of the electronic and optoelectronic devices.

Seong-Min Cho; Chang-Min Keum; Hea-Lim Park; Min-Hoi Kim; Jin-Hyuk Bae; Sin-Doo Lee

2014-01-01T23:59:59.000Z

284

Pulsed CO{sub 2} laser with an X-ray preioniser based on a high-voltage low-pressure glow discharge  

SciTech Connect

An X-ray preioniser with an electron beam energy density of 0.1 J cm{sup -2} based on a high-voltage (20 - 40 kV) low-pressure glow discharge is developed for repetitively pulsed gas lasers. The electron concentration in the CO{sub 2} - N{sub 2} - He mixture as a function of the voltage across the preioniser is calculated for titanium and other foils. The preioniser can be operated both in a single-pulse regime and at pulse repetition rates ranging up to hundreds of Hertz. A specific energy yield of 51 J L{sup -1} is achieved in the X-ray preionised pulsed CO{sub 2} atmospheric-pressure laser. This preioniser was shown to be efficient for other active media (CO and excimer lasers), which opens up new opportunities for the development of repetitively pulsed gas lasers. (lasers)

Oreshkin, V F; Seregin, Aleksandr M; Sinaiskii, V V; Shchetinkina, T A ['Astrofizika' Research and Production Association (Russian Federation); Sorokin, A R [Institute of Semiconductor Physics, Siberian Branch of the Russian Academy of Sciences, Novosibirsk (Russian Federation)

2003-12-31T23:59:59.000Z

285

Flat-Sag Cables with Semiactive Damping 1 FLAT-SAG CABLES WITH SEMIACTIVE DAMPING  

E-Print Network (OSTI)

the previous work by adding sag, inclination, and axial flexibility to the cable model. The equations of motion by semiactive dampers for a wide range of cable sag and damper location. KEYWORDS semiactive damping, rain-wind to environmental excitations, such as rain-wind induced vibration, and support excitations. Steel cables

Johnson, Erik A.

286

Semiactive Damping of Cables with Sag 1 SEMIACTIVE DAMPING OF CABLES WITH SAG  

E-Print Network (OSTI)

the previous work by adding sag, inclination, and axial flexibility to the cable model. The equations of motion by semiactive dampers for a wide range of cable sag and damper location. KEYWORDS semiactive damping, rain-wind to environmental excitations, such as rain-wind induced vibration, and support excitations. Steel cables

Spencer Jr., B.F.

287

Optimal Voltage Control of the Southern Norwegian Power Grid.  

E-Print Network (OSTI)

??This thesis contains the synthesis, analysis and simulation results of an automatic optimal voltage controller for the Southern Norwegian power grid. Currently the high voltage… (more)

Hannisdal, Erik Lundegaard

2011-01-01T23:59:59.000Z

288

Development of 100kVA AC superconducting coil using NbTi cables with a CuSi alloy matrix  

SciTech Connect

For implementation of AC superconducting equipment, it is imperative to develop low loss cables having highly stable characteristics. Here, newly developed NbTi superconducting cables using a CuSi alloy matrix are of low loss and are very promising as cables for practical application. However, since the CuSi alloy is a new material as a matrix for NbTi superconducting cables, many unknown factors as regards to optimum conditions for the manufacture of long cables, as well as superconducting characteristics are involved. For this new superconducting cable, a long strand (km class) was manufactured as a step for practical application, and a primary twisted cable was fabricated. Using this cable, a coil of the 100kVA class was fabricated for trial, and its performance characteristic with transport current was evaluated. This coil had no training phenomenon and had high stabilities. Furthermore, it permitted full AC current transmission of up to DCIc. Upon analysis of the coil loss, the hysteresis loss was smaller than coupling loss, and there was little increase of loss due to the current flow to the coil. consequently, by using CuSi alloy matrix superconducting cables, it was possible to provide an AC coil of low loss and high stability, and the present cable was found to be promising as a new AC superconducting cable in the future.

Kasahara, H.; Akita, S.; Torii, S. [CRIEPI, Tokyo (Japan)] [CRIEPI, Tokyo (Japan); Sugimoto, M.; Matsumoto, K.; Tanaka, Y. [Furukawa Electric Co., Ltd., Nikko (Japan)] [Furukawa Electric Co., Ltd., Nikko (Japan); Tachikawa, K. [Tokai Univ., Hiratsuka (Japan)] [Tokai Univ., Hiratsuka (Japan)

1996-07-01T23:59:59.000Z

289

> REPLACE THIS LINE WITH YOUR PAPER IDENTIFICATION NUMBER (DOUBLE-CLICK HERE TO EDIT) < 1 Abstract--In high current, high voltage, high temperature  

E-Print Network (OSTI)

and high current applications, such as HVDC transmission [1] or pulsed power application [2], a thyristor

Paris-Sud XI, UniversitƩ de

290

Vibration Testing of Bridge Stay Cables to Obtain Damping Values  

Science Journals Connector (OSTI)

This paper discusses a series of tests performed on a cable stayed bridge in British Columbia, Canada to obtain the cable damping properties. Free vibration tests were performed on selected cables, in two phases:...

Martin E. Turek; Carlos E. Ventura; Khaled Shawwaf

2011-01-01T23:59:59.000Z

291

FEM Analysis of Nb-Sn Rutherford-type Cables  

SciTech Connect

An important part of superconducting accelerator magnet work is the conductor. To produce magnetic fields larger than 10 T, brittle conductors are typically used. For instance, for Nb{sub 3}Sn the original round wire, in the form of a composite of Copper, Niobium and Tin, is assembled into a so-called Rutherford-type cable, which is used to wind the magnet. The magnet is then subjected to a high temperature heat treatment to produce the chemical reactions that make the material superconducting. At this stage the superconductor is brittle and its superconducting properties sensitive to strain. This work is based on the development of a 2D finite element model, which simulates the mechanical behavior of Rutherford-type cable before heat treatment. The model was applied to a number of different cable architectures. To validate a critical criterion adopted into the single Nb-Sn wire analysis, the results of the model were compared with those measured experimentally on cable cross sections.

Barzi, Emanuela; Gallo, Giuseppe; Neri, Paolo; /Fermilab

2011-01-01T23:59:59.000Z

292

Modeling and simulation of power cable insulation  

Science Journals Connector (OSTI)

The use of power cables for transmission and distribution of electrical power have increased since the advent of suitable, reliable and economical polymeric insulating material; such as cross-linked polyethylene (XLPE). Power cables plays crucial role ... Keywords: cross-linked polyethylene (XLPE), imperfect insulation, local defects, lossy insulation, partial discharge (PD)

K. D. Patil; A. A. Bhole; W. Z. Gandhare

2010-02-01T23:59:59.000Z

293

Geomagnetic induction on a transatlantic communications cable  

Science Journals Connector (OSTI)

... The solid line in Fig. 1 shows the approximate route of the TAT-6 cable across the North Atlantic (length 6,300 km). This ... across the North Atlantic (length 6,300 km). This cable is powered at both Green Hill and St Hilaire by constant current power supplies with ...

L. V. Medford; A. Meloni; L. J. Lanzerotti; G. P. Gregori

1981-04-02T23:59:59.000Z

294

New Round-the-World Telephone Cable  

Science Journals Connector (OSTI)

... THE construction of a round-the-world Commonwealth telephone cable was considered at the Commonwealth Trade and Economic Conference in Montreal. It was envisaged ... provision would be based on capital contributions from all Commonwealth countries and that the new cable could be operated on a self-supporting financial basis. The first trans-oceanic telephone ...

1958-10-04T23:59:59.000Z

295

Cable test raises fears at fusion project  

Science Journals Connector (OSTI)

... Scientists on three continents are scrambling to understand a potentially serious problem with superconducting cables destined for ITER, the world's largest fusion experiment. Nature has learned that preliminary ... ITER, the world's largest fusion experiment. Nature has learned that preliminary tests of cable for ITER's powerful central magnet show that it degrades too quickly to be used ...

Geoff Brumfiel

2011-03-08T23:59:59.000Z

296

Aircraft Defence against Barrage Balloon Cables  

Science Journals Connector (OSTI)

... , shot down recently, reveal the fact that these machines are fitted with a balloon cable fender not very different from designs tried by both sides during the latter part of ... on a pylon forward of the nose of the machine. Thus, when meeting a cable it is fended off by being slipped round the wing tip. The weight and ...

1942-01-17T23:59:59.000Z

297

On a Form of Artificial Submarine Cable  

Science Journals Connector (OSTI)

... , Mr. C. F. Varley, about the year 1860, devised an artificial submarine cable equivalent in its action to a real ... equivalent in its action to a real cable long enough to reach from England to Australia. For obvious reasons such a device ...

A. TROWBRIDGE

1901-05-23T23:59:59.000Z

298

An Internal Coaxil Cable Seal System  

DOE Patents (OSTI)

The invention is a seal system for a coaxial cable more specifically an internal seal system placed within the coaxial cable and its constituent components. A series of seal stacks including flexible rigid rings and elastomeric rings are placed on load bearing members within the coaxial cable. The current invention is adapted to seal the annular space between the coaxial cable and an electrical contact passing there through. The coaxial cable is disposed within drilling components to transmit electrical signals between drilling components within a drill string. During oil and gas exploration, a drill string can see a range of pressures and temperatures thus resulting in multiple combinations of temperature and pressure and increasing the difficulty of creating a robust seal for all combinations. The seal system can be used in a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David (Lehi, UT); Dahlgren, Scott (Provo, UT); Sneddon, Cameron (Provo, UT); Briscoe, Michael (Lehi, UT); Fox, Joe (Spanish Fork, UT)

2004-12-23T23:59:59.000Z

299

Do not exceed the operating input power, voltage, and current level and signal type appropriate for the instrument being used, refer to  

E-Print Network (OSTI)

operation. - Instrument generates high temperature or electrical shock during operation. - Power cable, plug below, immediately terminate operation and disconnect the power cable. Contact your local Agilent;Herstellerbescheinigung GER AUSCHEMISSION LpA Manufacturer

Anlage, Steven

300

Department of Mechanical Engineering Spring 2012 Synthetic Cable Termination  

E-Print Network (OSTI)

PENNSTATE Department of Mechanical Engineering Spring 2012 Synthetic Cable Termination Overview NAVAIR is attempting to replace their existing metallic purchase cable with a new, synthetic cable. The synthetic cable is currently not able to be tensile tested because there is no way for the ends

Demirel, Melik C.

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Vids4Grids: Smart Meters and Super Cables | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Grids: Smart Meters and Super Cables Grids: Smart Meters and Super Cables Vids4Grids: Smart Meters and Super Cables March 14, 2011 - 4:46pm Addthis This episode of Vids 4 Grids will take us to Itron's smart meter factory in West Union, SC where we will learn the role smart meters play in the Smart Grid. Deborah J. Buterbaugh Energy Project Specialist at National Energy Technology Laboratory What does this mean for me? Smart meters allow consumers to get real time information about their energy usage. Super cables help provide more reliable electricity to your home. In January we introduced you to the Vids4Grids project, a series of videos targeting students in high school and starting college. Through integration into curricula and online posting for open viewing, the project aims to increase awareness and create interest in power systems careers to help

302

Vids4Grids: Smart Meters and Super Cables | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Vids4Grids: Smart Meters and Super Cables Vids4Grids: Smart Meters and Super Cables Vids4Grids: Smart Meters and Super Cables March 14, 2011 - 4:46pm Addthis This episode of Vids 4 Grids will take us to Itron's smart meter factory in West Union, SC where we will learn the role smart meters play in the Smart Grid. Deborah J. Buterbaugh Energy Project Specialist at National Energy Technology Laboratory What does this mean for me? Smart meters allow consumers to get real time information about their energy usage. Super cables help provide more reliable electricity to your home. In January we introduced you to the Vids4Grids project, a series of videos targeting students in high school and starting college. Through integration into curricula and online posting for open viewing, the project aims to increase awareness and create interest in power systems careers to help

303

Peculiarities of the current-voltage characteristics of a Josephson medium in a YBCO high-temperature superconductor  

Science Journals Connector (OSTI)

The influence of a weak magnetic field (H high-temperature superconductor (HTSC) near the superconducting transitio...

M. A. Vasyutin

2013-12-01T23:59:59.000Z

304

RECIPIENT:Princeton Power Systems STATE: NJ PROJECT Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Princeton Power Systems Princeton Power Systems STATE: NJ PROJECT Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage TITLE: Funding Opportunity Announcement Number Procurement Instrument Number NEPA Control Number cm Number DE-FOA-0000293 DE-EE0003640 GFO-000364~001 GOO Based on my review of the information concerning the proposed action, as NEPA Compliance Officer (authorized under DOE Order 451.1A), I have made the foUowing determination: CX, EA, EIS APPENDIX AND NUMBER: Description: A9 Information gathering (including, but not limited to, ~terature surveys, inventories, audits), data analysis (including computer modeling), document preparation (such as conceptual design or feasibility studies, analytical energy supply

305

Influence of high voltage atmospheric cold plasma process parameters and role of relative humidity on inactivation of Bacillus atrophaeus spores inside a sealed package  

Science Journals Connector (OSTI)

SummaryBackground Non-thermal plasma has received much attention for elimination of microbial contamination from a range of surfaces. Aim This study aimed to determine the effect of a range of dielectric barrier discharge high voltage atmospheric cold plasma (HVACP) parameters for inactivation of Bacillus atrophaeus spores inside a sealed package. Methods A sterile polystyrene Petri dish containing B. atrophaeus spore strip (spore population 2.3 × 106/strip i.e. 6.36 log10/strip) was placed in a sealed polypropylene container and was subjected to HVACP treatment. The HVACP discharge was generated between two aluminium plate electrodes using a high voltage of 70 kVRMS. The effects of process parameters, including treatment time, mode of exposure (direct/indirect), and working gas types, were evaluated. The influence of relative humidity on HVACP inactivation efficacy was also assessed. The inactivation efficacy was evaluated using colony counts. Optical absorption spectroscopy (OAS) was used to assess gas composition following HVACP exposure. Findings A strong effect of process parameters on inactivation was observed. Direct plasma exposure for 60 s resulted in ?6 log10 cycle reduction of spores in all gas types tested. However, indirect exposure for 60 s resulted in either 2.1 or 6.3 log10 cycle reduction of spores depending on gas types used for HVACP generation. The relative humidity (RH) was a critical factor in bacterial spore inactivation by HVACP, where a major role of plasma-generated species other than ozone was noted. Direct and indirect HVACP exposure for 60 s at 70% RH recorded 6.3 and 5.7 log10 cycle reduction of spores, respectively. Conclusion In summary, a strong influence of process parameters on spore inactivation was noted. Rapid in-package HVACP inactivation of bacterial spores within 30–60 s demonstrates the promising potential application for reduction of spores on medical devices and heat-sensitive materials.

S. Patil; T. Moiseev; N.N. Misra; P.J. Cullen; J.P. Mosnier; K.M. Keener; P. Bourke

2014-01-01T23:59:59.000Z

306

Automatic voltage imbalance detector  

DOE Patents (OSTI)

A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

Bobbett, Ronald E. (Los Alamos, NM); McCormick, J. Byron (Los Alamos, NM); Kerwin, William J. (Tucson, AZ)

1984-01-01T23:59:59.000Z

307

Ignition distributor voltage generator  

SciTech Connect

This patent describes a voltage pulse generator and ignition distributor comprising, a base, a shaft rotatably supported by the base, a distributor cap supported by the base having a center electrode and circumferentially spaced outer electrodes. The pulse generator and ignition distribution also include a first rotor driven by the shaft formed of electrical insulating material having electrically conductive means connected to the center terminal and a portion that rotates past the outer electrodes. The portion of the electrically conductive means that rotates past the outer electrodes is spaced from the outer electrodes to form a gap therebetween. A voltage pulse generator comprises a second rotor driven by the shaft, at least one permanent magnet and an annular pickup coil supported by the base. The pickup coil has inner turns and outer turns, the beginning turn of the inner turns connected to a first lead and the last turn of the outer turns connected to a second lead, the outer turns enclosing the inner turns. The pickup coil also has a circuit connected directly between the second lead and ground which is operative to provide a direct conductive path to ground for high frequency energy capacitively coupled to the outer turns from the gap discharge between the electrically conductive means of the first rotor and an outer electrode, the outer turns forming a grounded shield for the inner turns.

Boyer, J.A.

1986-11-04T23:59:59.000Z

308

UNC CHARLOTTE TELECOMMUNICATIONS CABLING INFRASTRUCTURE BID ALTERNATE SPECIFICATIONS  

E-Print Network (OSTI)

APPENDIX D UNC CHARLOTTE TELECOMMUNICATIONS CABLING INFRASTRUCTURE BID ALTERNATE SPECIFICATIONS LIST #12;UNC Charlotte Telecommunications Cabling Infrastructure Bid Alternate Specifications List listed in paragraph one. Pricing must be submitted by the competing telecommunications companies based

Xie,Jiang (Linda)

309

Cable companies tied up in knots in international Pacific network  

Science Journals Connector (OSTI)

... corn market, has revealed ambitious plans to lay a network of trans-Pacific optical fibre cables to compete with a ... to compete with a cable to be laid by one of the new companies.

David Swinbanks

1987-10-08T23:59:59.000Z

310

A 4000-A HVDC (high-voltage direct-current) circuit breaker with fast fault-clearing capability: Final report  

SciTech Connect

This project is a follow-up of the first development of a 500 kV HVDC airblast circuit breaker (EPRI project 1507-3). The objective was to increase the current interrupting capability from 2200 A to 4000 A and shorten its fault clearing time. A high current 500 kV HVDC circuit breaker has been built using the passive commutation circuit. The breaker is modular in construction and can be designed for a wide variety of system conditions. More than 400 current interruptions were carried out successfully. Tests have shown that this circuit breaker is capable of interrupting more than 4000 A dc. Practical breakers with current interrupting capability of even 5500 A dc could be built. The circuit breaker operation and the fault-clearing process can be materially speeded up if the trip signal is given as soon as the fault is detected and without waiting for the current levels to come down in response to converter control action. The new dc breakers are shown to be capable of withstanding these transient arc currents of 8000 A without affecting its ability to interrupt the direct current that follows the transient. This transient current withstand capability is greater than is likely to occur during dc faults. The fault clearing time of this HVDC circuit breaker is comparable to the fault clearing time of conventional ac breakers for ac faults. The developed HVDC circuit breaker is now commercially available and can be supplied for use in HVDC systems. Its use in such systems is expected to provide flexibility in system design and contribute to system stability. 38 refs., 52 figs., 9 tabs.

Not Available

1988-04-01T23:59:59.000Z

311

Apparatus producing constant cable tension for intermittent demand  

DOE Patents (OSTI)

This invention relates to apparatus for producing constant tension in cable or the like when it is unreeled and reeled from a drum or spool under conditions of intermittent demand. The invention is particularly applicable to the handling of superconductive cable, but the invention is also applicable to the unreeling and reeling of other strands, such as electrical cable, wire, cord, other cables, fish line, wrapping paper and numerous other materials.

Lauritzen, T.

1984-05-23T23:59:59.000Z

312

Complete Fiber/Copper Cable Solution for Long-Term Temperature and Pressure  

Open Energy Info (EERE)

Complete Fiber/Copper Cable Solution for Long-Term Temperature and Pressure Complete Fiber/Copper Cable Solution for Long-Term Temperature and Pressure Measurement in Supercritical Reservoirs and EGS Wells Geothermal Project Jump to: navigation, search Last modified on July 22, 2011. Project Title Complete Fiber/Copper Cable Solution for Long-Term Temperature and Pressure Measurement in Supercritical Reservoirs and EGS Wells Project Type / Topic 1 Recovery Act: Enhanced Geothermal Systems Component Research and Development/Analysis Project Type / Topic 2 High-Temperature Downhole Tools Project Description Draka has engaged top academic, national laboratory and industry research scientists to develop the myriad of technical advances required - from glass chemistry to encapsulation metallurgy. Draka will develop the required advances in buffer tubing, cladding, wire insulation materials and cable packaging as well as coordinate activities of other participants. Draka Communications will develop the required advances in glass chemistry, fiber coatings and fiber drawing technologies. AltaRock Energy, Inc., a renewable energy company focused on research & development, will provide well field services and EGS wells for long-term testing and validation of the cable at Geysers, California. Tetramer has been engaged for the required advances in candidate materials for fiber coating and encapsulation technologies. Sandia will provide laboratory testing and validation of Draka's fiber solutions at elevated temperatures, pressures and hydrogen levels. Permatools (a Sandia EGS spin-off) will provide EGS tools to validate the finished cable design and will also coordinate in-well testing. Permatools (a Sandia EGS spin-off) will provide EGS tools to validate the finished cable design and will also coordinate in-well testing.

313

Dynamic analysis of the cables consider Dynamic analysis of the cables consider sag effect and flexural rigidity.  

E-Print Network (OSTI)

??In this paperļ¼the cable structures considering sag effect and flexural rigidity are used to the series of dynamic analysis.It dedatees on vibration of the cables… (more)

Chen, Wun-Shin

2005-01-01T23:59:59.000Z

314

Testing Results of Magnetostrictive Ultrasonic Sensor Cables for Signal Loss  

SciTech Connect

The purpose of this test was to determine the signal strength and resolution losses of a magnetostrictive ultrasonic system with an extended signal cable. The cable of interest carries electrical signals between the pulse generator/receiver and the magnetostrictive transducer. It was desired to determine the loss introduced by different lengths of the signal cable (6', 100', and 200').

JT Evans

2005-05-01T23:59:59.000Z

315

The Linear Theory of Free Vibrations of a Suspended Cable  

Science Journals Connector (OSTI)

...Theory of Free Vibrations of a Suspended Cable H. M. Irvine T. K. Caughey A linear...free vibrations of a uniform suspended cable in which the ratio of sag to span is about...parameter which allows for the effects of cable geometry and elasticity. The results of...

1974-01-01T23:59:59.000Z

316

New Developments in TDR Cable Surveillance of Potential Instability  

E-Print Network (OSTI)

New Developments in TDR Cable Surveillance of Potential Instability C.H. Dowding, M.L. Dussud & K employs a case history to describe deployment of new TDR cable and communication technologies to monitor" installed over a recent subsidence event. A TDR cable was installed horizontally along with more typical

317

CABLE-SUSPENDED HAPTIC INTERFACE Robert L. Williams II  

E-Print Network (OSTI)

1 CABLE-SUSPENDED HAPTIC INTERFACE Robert L. Williams II Department of Mechanical Engineering Ohio@bobcat.ent.ohiou.edu URL: http://www.ent.ohiou.edu/~bobw #12;2 CABLE-SUSPENDED HAPTIC INTERFACE Robert L. Williams II Ohio University Athens, OH 45701 ABSTRACT A cable-suspended haptic interface (CSHI) concept is presented. The goal

Williams II, Robert L.

318

Substation voltage upgrading  

SciTech Connect

This report addresses specific issues to support sound yet not unduly conservative uprating practices for substations. The main parts of the report cover the insulation withstand and overvoltage protection aspects, environmental measurements, reliability criteria, and industry experience. First the insulation design concerns are addressed. Substation stress by a backflashover of the line insulation due to lightning in the vicinity of the substation is recognized as a critical stress. A representative part of a 550 kV BIL substation was erected at the EPRI High Voltage Transmission Research Center, where also a special test circuit was assembled to produce a fast front, slow tail (0.2/200 {mu}s) wave. The substation as well as some special configurations were tested for line-to-ground and line-to-line withstand. Computer studies were performed to complement the test results. A number of important conclusions was reached. The most prominent result in that the high frequency oscillations, as caused by reflections within the substation, do not effect the Critical Flashover Voltage (CFO). The present practice, based on the highest peak is therefore very conservative. The slow tail of the wave appears to dictate the CFO. An arrester model for computer studies to represent very fast as well as slow phenomena was derived. It is based on full scale arrester test data, made available in this project. The computer program to calculate arrester model parameters is also a part of the report. The electric environmental measurements are reported for the tested substation at the HVTRC and for the uprated substation of Public Service Company of Colorado, both before and after the uprating. The performance is satisfactory when corona free hardware is used. Insulation design criteria are analyzed based on substation reliability, the system viewpoint and consequences of the failure. Utility experience with uprated substations is reviewed.

Panek, J.; Elahi, H.; Lux, A.; Imece, A.F. (General Electric Co., Schenectady, NY (United States). Power Systems Engineering Dept.); LaPanse, R.A.; Stewart, J.R. (Public Service Co. of Colorado, Denver, CO (United States))

1992-04-01T23:59:59.000Z

319

Identification of weak non-linearities in cables of cable-stayed footbridges  

Science Journals Connector (OSTI)

A time-frequency identification technique for the non-linear identification of a cable element was proposed in this paper. A polynomial form of non-parametric method was used. A long cable of a newly constructed cable-stayed footbridge was modelled in the ANSYS structural software. The model was reduced to a SDoF system, by applying a harmonic force in the first modal frequency and the first mode shape. A good match between the identified and numerical data was obtained. Some interesting non-linear phenomena were observed: only a cubic type of non-linearity was identified. Moreover, the values of the damping and cubic parameters stabilised at higher load amplitudes. However, parameter relevant to linear-frequency was increasing with the loading amplitude showing a typical hardening behaviour of cable structures. Superharmonics were present in the response at higher loading amplitudes. Therefore, the identification procedure was found to be effective at higher load amplitudes.

Anil Kumar; Luca Zanotti Fragonara

2013-01-01T23:59:59.000Z

320

Flexing Cable for Wind Power Applications  

Science Journals Connector (OSTI)

As conventional energy sources -- namely oil, gas, and coal -- are increasingly limited in their respective quantities, many countries are encouraging the development of renewable energies. Wind energy, already a well-developed technology, is quickly ... Keywords: Wind Power, Flexing, Cable, energy, Flexibility

Wenyan Qiu; Huili Zhang; Lu Li

2012-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

High-Voltage Test Laboratories  

Science Journals Connector (OSTI)

The power for a complete HV laboratory is usually supplied from a medium-...9.20...). One or several three-phase distribution transformers in a nearby substation should be used for that purpose. Their...Sect. 9.2...

Wolfgang Hauschild; Eberhard Lemke

2014-01-01T23:59:59.000Z

322

Classification of Voltage Sags Based on MPCA Models  

Science Journals Connector (OSTI)

In this paper, we introduce a new framework for classification of short duration voltage reductions in the area of Power Quality Monitoring using Multiway Principal Component Analysis (MPCA). Firstly, we recast the sags occurred in High Voltage (HV) ...

Abbas Khosravi; Joaquim Melendez; Joan Colomer

2007-06-01T23:59:59.000Z

323

Modulated voltage metastable ionization detector  

SciTech Connect

Metastable ionization detectors used for chromatographic analysis usually employa fixed high voltage for the ionization potential. For this reason, the operating range is limited to about three orders of magnitude. By use of the technique disclosed in the instant invention, operating ranges of about nine orders of magnitude are obtained. The output current from a metastable ionization detector (MID) is applied to a modulation voltage circuit. An adjustment is made to balance out the background current, and an output current, above background, is applied to an input of a strip chart recorder. For low level concentrations, i.e., low detected output current, the ionization potential will be at a maximum and the metastable ionization detector will operate at its most sensitive level. When the detected current from the metastable ionization detector increases above a predetermined threshold level, a voltage control circuit is activated which turns on a high voltage transistor which acts to reduce the ionization potential. The ionization potential applied to the metastable ionization detector is then varied so as to maintain the detected signal level constant. The variation in ionization potential is now related to the concentration fo the constituent and a representative amplitude is applied to another input of said strip chart recorder.

Carle, G. C.; Humphry, D. E.; Kojiro, D. R.

1985-08-27T23:59:59.000Z

324

Vehicle Technologies Office Merit Review 2014: High Energy Density Li-ion Cells for EV’s Based on Novel, High Voltage Cathode Material Systems  

Energy.gov (U.S. Department of Energy (DOE))

Presentation given by Farasis Energy, Inc. at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about high energy density Li...

325

SpiderBot: a cable-suspended walking robot  

Science Journals Connector (OSTI)

Abstract This paper presents a novel concept of a mobile cable-suspended robot called SpiderBot. The robot consists of four cable-mechanisms and a central body. Each cable-mechanism includes a cable, a dispensing and rolling mechanism, and a gripper at the end of the cable. The robot shoots an arrow-like grasping mechanism towards possible grasping points. The grasping mechanism is attached to the distal end of the cable. Then it pulls the cables simultaneously in a coordinated manner, hence the robot can perform controlled motion of the central body. Depending on the locations of the grasping points and the coordinated pulling, the robot can perform motion around and over obstacles. In this paper the design, kinematics, statics, motion planning, simulation results and experiments that were conducted are presented using our SpiderBot prototype.

A. Capua; A. Shapiro; S. Shoval

2014-01-01T23:59:59.000Z

326

Testing of 3-meter Prototype Fault Current Limiting Cables  

SciTech Connect

Two 3-m long, single-phase cables have been fabricated by Ultera from second generation (2G) superconductor supplied by American Superconductor. The first cable was made with two layers of 2G tape conductor and had a critical current of 5,750 A while the second cable had four layers and a critical current of 8,500 A. AC loss was measured for both cables at ac currents of up to 4 kArms. Ultera performed initial fault current studies of both cables in Denmark with limited currents in the range from 9.1 to 44 kA. Results from these tests will provide a basis for a 25-m long, three-phase, prototype cable to be tested at ORNL early next year and a 300-m long, fault current limiting, superconducting cable to be installed in a ConEd substation in New York City.

Gouge, Michael J [ORNL] [ORNL; Duckworth, Robert C [ORNL] [ORNL; Demko, Jonathan A [ORNL] [ORNL; Rey, Christopher M [ORNL] [ORNL; Thompson, James R [ORNL] [ORNL; Lindsay, David T [ORNL] [ORNL; Tolbert, Jerry Carlton [ORNL] [ORNL; Willen, Dag [Ultera] [Ultera; Lentge, Heidi [Ultera] [Ultera; Thidemann, Carsten [Ultera] [Ultera; Carter, Bill [AMSC] [AMSC

2009-01-01T23:59:59.000Z

327

Low Voltage Electrostatic Actuation and Displacement Measurement through Resonant Drive Circuit.  

E-Print Network (OSTI)

??An electrostatic actuator driven by conventional voltage control and charge control requires high actuation voltage and suffers from the pull-in phenomenon that limits its operation… (more)

Park, Sangtak

2011-01-01T23:59:59.000Z

328

Research to Prevent the Anti-charging Incident of the Voltage Transformer in the Substation  

Science Journals Connector (OSTI)

The voltage transformer of the power system is a device which converts the high voltage of the primary side into the low voltage required by secondary device, and the primary side connects to the primary syste...

Hui-Ying Chen; Zhi-Peng Wang; Mu-Qin Tian

2011-01-01T23:59:59.000Z

329

Optimal Selection of AC Cables for Large Scale Offshore Wind Farms  

E-Print Network (OSTI)

Optimal Selection of AC Cables for Large Scale Offshore Wind Farms Peng Hou, Weihao Hu, Zhe Chen@et.aau.dk, whu@iet.aau.dk, zch@iet.aau.dk Abstract--The investment of large scale offshore wind farms is high the operational requirements of the offshore wind farms and the connected power systems. In this paper, a new cost

Hu, Weihao

330

HTS cables open the window for large-scale renewables  

Science Journals Connector (OSTI)

In a realistic approach to future energy consumption, the effects of sustainable power sources and the effects of growing welfare with increased use of electricity need to be considered. These factors lead to an increased transfer of electric energy over the networks. A dominant part of the energy need will come from expanded large-scale renewable sources. To use them efficiently over Europe, large energy transits between different countries are required. Bottlenecks in the existing infrastructure will be avoided by strengthening the network. For environmental reasons more infrastructure will be built underground. Nuon is studying the HTS technology as a component to solve these challenges. This technology offers a tremendously large power transport capacity as well as the possibility to reduce short circuit currents, making integration of renewables easier. Furthermore, power transport will be possible at lower voltage levels, giving the opportunity to upgrade the existing network while re-using it. This will result in large cost savings while reaching the future energy challenges. In a 6 km backbone structure in Amsterdam Nuon wants to install a 50 kV HTS Triax cable for a significant increase of the transport capacity, while developing its capabilities. Nevertheless several barriers have to be overcome.

A Geschiere; D Willén; E Piga; P Barendregt

2008-01-01T23:59:59.000Z

331

Superconducting Cable Having A Felexible Former  

DOE Patents (OSTI)

In order to provide a flexible oxide superconducting cable which is reduced in AC loss, tape-shaped superconducting wires covered with a stabilizing metal are wound on a flexible former. The superconducting wires are preferably laid on the former at a bending strain of not more than 0.2%. In laying on the former, a number of tape-shaped superconducting wires are laid on a core member in a side-by-side manner, to form a first layer. A prescribed number of tape-shaped superconducting wires are laid on top of the first layer in a side-by-side manner, to form a second layer. The former may be made of a metal, plastic, reinforced plastic, polymer, or a composite and provides flexibility to the superconducting wires and the cable formed therewith.

Hughey, Raburn L. (Franklin, GA); Sinha, Uday K. (Carrollton, GA); Reece, David S. (Carrollton, GA); Muller, Albert C. (Eidson, TN)

2005-03-15T23:59:59.000Z

332

Superconducting Cable Having A Flexible Former  

DOE Patents (OSTI)

In order to provide a flexible oxide superconducting cable which is reduced in AC loss, tape-shaped superconducting wires covered with a stabilizing metal are wound on a flexible former. The superconducting wires are preferably laid on the former at a bending strain of not more than 0.2%. In laying on the former, a number of tape-shaped superconducting wires are laid on a core member in a side-by-side manner, to form a first layer. A prescribed number of tape-shaped superconducting wires are laid on top of the first layer in a side-by-side manner, to form a second layer. The former may be made of a metal, plastic, reinforced plastic, polymer, or a composite and provides flexibility to the superconducting wires and the cable formed therewith.

Hughey, Raburn L. (Franklin, GA); Sinha, Uday K. (Carrollton, GA); Reece, David S. (Carrollton, GA); Muller, Albert C. (Eidson, TN)

2005-08-30T23:59:59.000Z

333

Constant voltage ultracapacitor  

Science Journals Connector (OSTI)

Ultracapacitors have attracted lots of attention recently due to their growing use in hybrid vehicles and in energy storage applications for the smart grid. A very undesirable feature of ultracapacitors is the fact that the voltage drops as the capacitor is discharged. DC-DC converters are employed at present to convert the voltage of the ultracapacitor to constant voltage; however these converters typically do not operate if the voltage of the ultracapacitor drops below 1?V. In addition DC-DC converters suffer from well-known size/efficiency tradeoffs. This paper introduces a novel new ultracapacitor that is characterized by constant voltage. The new ultracapacitor does not utilize familiar energy conversion principles. Rather operation depends on an embedded electromechanical system that actually alters the capacitance of the ultracapacitor as the device is discharged. Due to a simple proportionality relationship between charge capacitance and voltage the voltage remains constant. Theoretical and experimental investigations have shown that the embedded mechanism for altering the capacitance has an efficiency of 99% or higher.

Ezzat G. Bakhoum

2012-01-01T23:59:59.000Z

334

Substation voltage upgrading  

SciTech Connect

Substation voltage uprating, i.e., conversion of a substation from a lower rated voltage to a higher rated voltage without a complete substation rebuild, can lead to excellent economic benefits. Utilization of the old substation layout and/or the existing equipment, to some extent, is the practical objective of such an uprating. The objective of this project was to assess the opportunities for substation uprating in the industry, to establish feasibility for such uprating and to study methods for accomplishing it. The final aim of the project was to provide guidance to utilities interested in uprating. 56 refs., 41 figs., 18 tabs.

Panek, J.; Elahi, H.; Sublich, M. (General Electric Co., Schenectady, NY (USA). Systems Development and Engineering Dept.)

1989-08-01T23:59:59.000Z

335

The Matrix Converter Drive Performance Under Abnormal Input Voltage Conditions  

E-Print Network (OSTI)

that generates variable magnitude variable frequency output voltage from the ac utility line. It has high power voltage disturbance related performance issues of the MC drive. Since the MC is a direct frequencyThe Matrix Converter Drive Performance Under Abnormal Input Voltage Conditions Jun-Koo Kang

Hava, Ahmet

336

Phase Transitions and High-Voltage Electrochemical Behavior of LiCoO2 Thin Films Grown by Pulsed Laser Deposition  

E-Print Network (OSTI)

Laser Deposition H. Xia,a L. Lu,b,z Y. S. Meng,c and G. Cederc, * a Advanced Materials for Micro behavior of LiCoO2 thin-film cathodes prepared by pulsed laser deposition are studied for charging voltages- discharge curves. Ex situ X-ray diffraction measurements confirm structural changes and a phase transition

Ceder, Gerbrand

337

Intrinsic Surface Stability in LiMn2-xNixO4-d (x=0.45, 0.5) High Volt-age Spinel Materials for Lithium Ion Batteries  

SciTech Connect

This work reports the surface stability of the high voltage Li ion cathode LiMn2-xNixO4- (x= 0.5, 0.45) by comparing thin film and powder composite electrodes after cycling using X-ray photoelectron spectroscopy. The thin film electrodes offer the ability to probe the surface of the material without the need of a conductive agent and polymer binder typically used in composite electrodes. The results suggest that neither oxidation of PF6 to POF5 nor the decomposition of ethylene carbonate or dimethylene carbonate occurs on the surface of the spinel material. These results confirm the enhanced cycling stability and rate capability associated with the high voltage spinel material and suggests that the SEI layer forms due to the reaction of electrochemically inactive components in composite electrodes with the electrolyte.

Carroll, Kyler J [University of California, San Diego; Yang, Ming-Che [University of Florida, Gainesville; Veith, Gabriel M [ORNL; Dudney, Nancy J [ORNL; Meng, Ying Shirley [University of California, San Diego

2012-01-01T23:59:59.000Z

338

Analysis and design of an electronic voltage ratchet  

E-Print Network (OSTI)

and decay. Impulse voltages are produced through the discharging of 0, capacitor into a shaping network consisting of resistors and a. capacitor as is shown in Figure 2. 9. The operation of the impulse generator is as follows. Capacitor Ci is charged from... voltage shaping network. as possible in order to reduce oscillations in the wavefront and wavetail portions of the impulse voltage [1). The impulse voltage generator requires a, highly charged capacitor or bank of capacitors. Capacitors may be charged...

Menendez, Jorge Carlos

2012-06-07T23:59:59.000Z

339

Armored spring-core superconducting cable and method of construction  

DOE Patents (OSTI)

An armored spring-core superconducting cable (12) is provided. The armored spring-core superconducting cable (12) may include a spring-core (20), at least one superconducting strand (24) wound onto the spring-core (20), and an armored shell (22) that encases the superconducting strands (24). The spring-core (20) is generally a perforated tube that allows purge gases and cryogenic liquids to be circulated through the armored superconducting cable (12), as well as managing the internal stresses within the armored spring-core superconducting cable (12). The armored shell (22) manages the external stresses of the armored spring-core superconducting cable (12) to protect the fragile superconducting strands (24). The armored spring-core superconducting cable (12) may also include a conductive jacket (34) formed outwardly of the armored shell (22).

McIntyre, Peter M. (611 Montclair, College Station, TX 77840); Soika, Rainer H. (1 Hensel, #X4C, College Station, TX 77840)

2002-01-01T23:59:59.000Z

340

x.0 Handling of White SVT Cables (SVT Excess Cables) before and during Withdrawing of Endcap In general we (UC Santa Cruz) prefer to do all handling of the white SVT cables necessary to withdraw and reinsert  

E-Print Network (OSTI)

13 x.0 Handling of White SVT Cables (SVT Excess Cables) before and during Withdrawing of Endcap In general we (UC Santa Cruz) prefer to do all handling of the white SVT cables necessary to withdraw@scipp.ucsc.edu, office in SC: (831) 459Ā­3337 , extn. at SLAC: 8561. The white SVT cables consist of two parts

California at Santa Cruz, University of

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Design features of a cable–bollard vehicle barrier system  

Science Journals Connector (OSTI)

The design features of the stand-alone cable–bollard vehicle barrier system (Cable-Bollard VBS) developed for the Vermont Yankee Nuclear Power Plant (VY) to meet the design goals of the recent 10 CFR Part 73 rule changes are discussed. The design is based on the application of fundamental engineering principles to a dynamic system, recognizing that vehicle impact on a cable system is fundamentally different from vehicle impact on a bollard or other hard barrier. As such, rigorous attention is paid to cable anchor design and performance.

Gordon S. Bjorkman; Steven P. Harris

1998-01-01T23:59:59.000Z

342

Development of scaling rules for Rutherford type superconducting cables  

SciTech Connect

During the R D phase of the Superconducting Supercollider (SSC) program, LBL was responsible for establishing the parameters for cables used in SSC dipole and quadrupole magnets. In addition, the design and fabrication of a new cable for use in the Low Beta Quadrupoles. As a result of the development work on these and other cables, we have arrived a set of scaling rules which provide guidelines for choosing the parameters for a wide range of superconducting cables. These parameters include strand size, strand number, keystone angle, percent compaction, cable pitch and compacted cable dimensions. In addition, we have defined the tolerance ranges for the key cable manufacturing parameters such as mandrel size and shape, stand tension, and Turkshead temperature control. In this paper, we present the results on cables ranging from 8 strands to 36 strands of 0.65mm wire and from 8 strands to 30 strands of 0.8mm wire. We use these results to demonstrate the application of the scaling rules for Rutherford-type cable.

Royet, J.M.; Scanlan, R.M.

1990-09-01T23:59:59.000Z

343

Analysis and design of cable-driven parallel kinematic mechanisms.  

E-Print Network (OSTI)

??This thesis concerns the analysis and design of cable-driven parallel mechanisms (CDPM). Structurally, a CDPM is formed by replacing the supporting legs of a parallel… (more)

Pham, Cong Bang.

2008-01-01T23:59:59.000Z

344

Losses and Inductive Parameters in Subsea Power Cables.  

E-Print Network (OSTI)

?? Four samples of galvanized steel armour for sub sea power cables are tested with an electric steel tester. The samples exhibit di?erent remanence magnetization… (more)

Stųlan, Ronny

2009-01-01T23:59:59.000Z

345

Policy Name: Telecommunications Cabling and Wiring Originating/Responsible Department: Computing & Communication Services (CCS)  

E-Print Network (OSTI)

Policy Name: Telecommunications Cabling and Wiring Originating/Responsible Department: Computing Officer (CIO) Policy: Telecommunications Cabling and Wiring Purpose: The purpose of this Policy is to define responsibility and accountability for telecommunications cabling and wiring within the Carleton

Carleton University

346

Electro-optical voltage sensor head  

DOE Patents (OSTI)

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Idaho Falls, ID)

1998-01-01T23:59:59.000Z

347

Voltage stabilization system in traction substation of urban electric transport  

Science Journals Connector (OSTI)

The direct current-voltage stabilization system using a high-frequency link in traction substations of urban electric transport based on applying...

S. V. Shapiro; S. F. Muftiev

2011-02-01T23:59:59.000Z

348

Mechanical design of submarine power cables for floating platforms  

SciTech Connect

The process of mechanical design of submarine power cables employed by the Simplex Wire and Cable Company is described. The process commences with design criteria and proceeds through preliminary design, load and stress analyses and culminates in extreme value reliability and lifetime predictions. The analytical methods employed are emphasized and some representative numerical results are presented.

Bisplinghoff, R. L.; Libby, D. O.; Costantino, R. W.

1980-01-01T23:59:59.000Z

349

Cables, Paths and \\Subconscious" Reasoning Propositional Semantic Networks  

E-Print Network (OSTI)

Cables, Paths and \\Subconscious" Reasoning in Propositional Semantic Networks Stuart C. Shapiro represented by the propositional node, the label This is a preliminary version of S. C. Shapiro, Cables, paths-7022 (716) 636-3182 shapiro@cs.bu alo.edu 1 Introduction In this paper, I will discuss two aspects of SNe

Shapiro, Stuart C.

350

The Cable Repair Ship H.M.T.S. Monarch  

Science Journals Connector (OSTI)

... -6), members of the general public had an opportunity of inspecting the Post Office cable repair ship Monarch, which was lying in the Thames off the Tower. This ship ... fitted out with the special gear necessary for carrying out all the operations required in cable laying and repair, on which service she is at sea for most of the ...

1934-10-06T23:59:59.000Z

351

Microsoft Word - SAND2013-2448P - FY13Q2 Field Aged Cable Assesment...  

NLE Websites -- All DOE Office Websites (Extended Search)

but could be confirmed at a later date) cable (bonded jacketinsulation) from the Zion Nuclear Power Station. Physical property testing was performed on the as received cables....

352

EVALUATING IMPACT ON AMPACITY ACCORDING TO IEC-60287 REGARDING THERMALLY UNFAVOURABLE PLACEMENT OF POWER CABLES.  

E-Print Network (OSTI)

?? According to International Electrotechnical Commission’s standard document IEC-60287 the current carrying capabilities of power cables can be mathematically modelled. Current rating of power cables… (more)

Lindström, Ludvig

2011-01-01T23:59:59.000Z

353

Low voltage arc formation in railguns  

DOE Patents (OSTI)

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, R.S.

1985-08-05T23:59:59.000Z

354

Low voltage arc formation in railguns  

DOE Patents (OSTI)

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile. 2 figs.

Hawke, R.S.

1987-11-17T23:59:59.000Z

355

Low voltage arc formation in railguns  

DOE Patents (OSTI)

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, Ronald S. (Livermore, CA)

1987-01-01T23:59:59.000Z

356

Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage: Feasibility, image quality, radiation dose, and effect of iterative reconstruction  

Science Journals Connector (OSTI)

AbstractBackground Low tube voltage reduces radiation exposure in coronary CT angiography (CTA). Using 70 kVp tube potential has so far not been possible because CT systems were unable to provide sufficiently high tube current with low voltage. Objective We evaluated feasibility, image quality (IQ), and radiation dose of coronary CTA using a third-generation dual-source CT system capable of producing 450 mAs tube current at 70 kVp tube voltage. Methods Coronary CTA was performed in 26 consecutive patients with suspected coronary artery disease, selected for body weight pitch spiral acquisition was used. Filtered back projection (FBP) and iterative reconstruction (IR) algorithms were applied. IQ was assessed using a 4-point rating scale (1 = excellent, 4 = nondiagnostic) and objective parameters. Results Mean age was 62 ± 9 years (46% males; mean body mass index, 27.7 ± 3.8 kg/m2; mean heart rate, 54 ± 5 beats/min). Mean dose-length product was 20.6 ± 1.9 mGy × cm; mean estimated effective radiation dose was 0.3 ± 0.03 mSv. Diagnostic IQ was found in 365 of 367 (FBP) and 366 of 367 (IR) segments (P nonsignificant). IQ was rated “excellent” in 53% (FBP) and 86% (IR) segments (P = .001) and “nondiagnostic” in 2 (FBP) and 1 segment (IR) (P nonsignificant). Mean IQ score was lesser in FBP vs IR (1.5 ± 0.4 vs 1.1 ± 0.2; P pitch spiral acquisition and 70 kVp tube voltage is feasible and provides both robust IQ and very low radiation exposure.

Michaela M. Hell; Daniel Bittner; Annika Schuhbaeck; Gerd Muschiol; Michael Brand; Michael Lell; Michael Uder; Stephan Achenbach; Mohamed Marwan

2014-01-01T23:59:59.000Z

357

Prospects of High Temperature Superconductors for fusion magnets and power applications  

Science Journals Connector (OSTI)

Abstract During the last few years, progress in the field of second-generation High Temperature Superconductors (HTS) was breathtaking. Industry has taken up production of long length coated REBCO conductors with reduced angular dependency on external magnetic field and excellent critical current density jc. Consequently these REBCO tapes are used more and more in power application. For fusion magnets, high current conductors in the kA range are needed to limit the voltage during fast discharge. Several designs for high current cables using High Temperature Superconductors have been proposed. With the REBCO tape performance at hand, the prospects of fusion magnets based on such high current cables are promising. An operation at 4.5 K offers a comfortable temperature margin, more mechanical stability and the possibility to reach even higher fields compared to existing solutions with Nb3Sn which could be interesting with respect to DEMO. After a brief overview of HTS use in power application the paper will give an overview of possible use of HTS material for fusion application. Present high current HTS cable designs are reviewed and the potential using such concepts for future fusion magnets is discussed.

Walter H. Fietz; Christian Barth; Sandra Drotziger; Wilfried Goldacker; Reinhard Heller; Sonja I. Schlachter; Klaus-Peter Weiss

2013-01-01T23:59:59.000Z

358

Magnetic relaxation, current-voltage characteristics, and possible dissipation mechanisms for high-Tc superconducting thin films of Y-Ba-Cu-O  

Science Journals Connector (OSTI)

We propose a mechanism that may account for the temperature-insensitive relaxation of the magnetic-shielding current in epitaxial thin films of YBa2Cu3O7-?. We show that such relaxation is related to the shape of the current-voltage (J-E) characteristic of the superconductor in its critical state. The weak temperature dependence of the relaxation implies a temperature-insensitive J-E characteristic that resembles that of conventional type-II superconductors when a spatial variation of critical current density (Jc) is present. We suggest such a distribution of Jc as an explanation for the apparently large and temperature-insensitive relaxation observed in YBa2Cu3O7-?.

J. Z. Sun; C. B. Eom; B. Lairson; J. C. Bravman; T. H. Geballe

1991-02-01T23:59:59.000Z

359

Antenna mechanism of length control of actin cables  

E-Print Network (OSTI)

Actin cables are linear cytoskeletal structures that serve as tracks for myosin-based intracellular transport of vesicles and organelles in both yeast and mammalian cells. In a yeast cell undergoing budding, cables are in constant dynamic turnover yet some cables grow from the bud neck toward the back of the mother cell until their length roughly equals the diameter of the mother cell. This raises the question: how is the length of these cables controlled? Here we describe a novel molecular mechanism for cable length control inspired by recent experimental observations in cells. This antenna mechanism involves three key proteins: formins, which polymerize actin, Smy1 proteins, which bind formins and inhibit actin polymerization, and myosin motors, which deliver Smy1 to formins, leading to a length-dependent actin polymerization rate. We compute the probability distribution of cable lengths as a function of several experimentally tuneable parameters such as the formin-binding affinity of Smy1 and the concentration of myosin motors delivering Smy1. These results provide testable predictions of the antenna mechanism of actin-cable length control.

Lishibanya Mohapatra; Bruce L. Goode; Jane Kondev

2014-11-15T23:59:59.000Z

360

FEMCAM Analysis of SULTAN Test Results for ITER Nb3SN Cable-conduit Conductors  

SciTech Connect

Performance degradation due to filament fracture of Nb3 Sn cable-in-conduit conductors (CICCs) is a critical issue in large-scale magnet designs such as ITER which is currently being constructed in the South of France. The critical current observed in most SULTAN TF CICC samples is significantly lower than expected and the voltage-current characteristic is seen to have a much broader transition from a single strand to the CICC. Moreover, most conductors exhibit the irreversible degradation due to filament fracture and strain relaxation under electromagnetic cyclic loading. With recent success in monitoring thermal strain distribution and its evolution under the electromagnetic cyclic loading from in situ measurement of critical temperature, we apply FEMCAM which includes strand filament breakage and local current sharing effects to SULTAN tested CICCs to study Nb3 Sn strain sensitivity and irreversible performance degradation. FEMCAM combines the thermal bending effect during cool down and the EM bending effect due to locally accumulating Lorentz force during magnet operation. It also includes strand filament fracture and related local current sharing for the calculation of cable n value. In this paper, we model continuous performance degradation under EM cyclic loading based on strain relaxation and the transition broadening upon cyclic loading to the extreme cases seen in SULTAN test data to better quantify conductor performance degradation.

Yuhu Zhai, Pierluigi Bruzzone, Ciro Calzolaio

2013-03-19T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Method for fabricating multi-strand superconducting cable  

DOE Patents (OSTI)

Multi-strand superconducting cables adapted to be used, for example, to wind a magnet are fabricated by directing wire strands inwardly from spools disposed on the perimeter of a rotating disk and wrapping them diagonally around a tapered mandrel with a flattened cross-sectional shape with a core having a wedge-shaped channel. As the cable is pulled axially, flexibly coupled wedge-shaped pieces are continuously passed through the channel in the mandrel and inserted into the cable as an internal support therefor.

Borden, A.R.

1985-04-01T23:59:59.000Z

362

An Internal Coaxial Cable Electrical Connector For Use In Downhole Tools  

DOE Patents (OSTI)

A coaxial cable electrical connector more specifically an internal coaxial cable connector placed within a coaxial cable and its constituent components. A coaxial cable connector is in electrical communcation with an inductive transformer and a coaxial cable. The connector is in electrical communication with the outer housing of the inductive transfonner. A generally coaxial center conductor, a portion of which could be the coil in the inductive transformer, passes through the connector, is electrically insulated from the connector, and is in electrical communication with the conductive care of the coaxial cable. A plurality of bulbous pliant tabs on the coaxial cable connector mechanically engage the inside diameter of the coaxial cable thus grounding the transformer to the coaxial cable. The coaxial cable and inductive transformer are disposed within downhole tools to transmit electrical signals between downhole tools within a drill string.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David S. (Lehi, UT); Dahlgren, Scott (Provo, UT); Fox, Joe (Spanish Fork, UT); Sneddon, Cameron (Provo, UT); Briscoe, Michael (Lehi, UT)

2005-11-29T23:59:59.000Z

363

Electro-optic voltage sensor for sensing voltage in an E-field  

DOE Patents (OSTI)

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Idaho Falls, ID); Renak, Todd W. (Idaho Falls, ID)

1999-01-01T23:59:59.000Z

364

Reliability of the spark inspection of cable product insulation  

Science Journals Connector (OSTI)

The types of manufacturing flaws in cable products and the causes of their occurrence were studied. Methods for improving the reliability of the detection of flaws and the classification of flaws that are dete...

V. V. Red’ko; L. B. Burtseva; L. A. Red’ko

2011-10-01T23:59:59.000Z

365

Cable length optimization for trawl fuel consumption reduction  

Science Journals Connector (OSTI)

A numerical method for optimization of the cable lengths in trawls with respect to the ratio between the estimated trawl drag and the predicted catch efficiency is developed and applied. The trawl cables of interest are warps, bridles, headline and footrope. The optimization algorithm applies an ordered sequential process changing one cable length at the time. It is assumed in the predictions that the catch efficiency of the trawl is proportional with the trawl mouth area. In a case study optimizing a bottom trawl used on a research vessel by applying the new method it is predicted that it would be possible to reduce the ratio between trawl drag and catch efficiency by up to 46% by optimizing the cable lengths. Thus this would enable a considerable reduction in fuel consumption to catch a specific amount of fish. Moreover, we predict an increase in the value of the trawl mouth area leading to better catching efficiency without increase in otter door drag.

Ramez Khaled; Daniel Priour; Jean-Yves Billard

2013-01-01T23:59:59.000Z

366

8 - Superconducting fault current limiters and power cables  

Science Journals Connector (OSTI)

Abstract: This chapter addresses the technology of superconducting power cables and superconducting fault current limiters. The first part of the chapter is a general summary of the electric power grid. This sets the stage for a discussion of the historical development of superconducting AC and DC cables, which begins with low temperature superconductor-based systems. It then describes the present state of superconducting cable technology and gives a summary of some of the major programs around the world. Whereas power cables may be thought of as a replacement for conventional power system components, fault current limiters and fault current controllers have no conventional equivalent in the power grid. Several conceptually different fault current limiter designs are described. Their state of development and installation on the power grid are described.

W. Hassenzahl

2012-01-01T23:59:59.000Z

367

9 - Superconducting fault current limiters and power cables  

Science Journals Connector (OSTI)

Abstract: This chapter addresses the technology of superconducting power cables and superconducting fault current limiters (FCL). The first part of the chapter is a general summary of the electric power grid. This sets the stage for a discussion of the historical development of superconducting AC and DC cables, which begins with low temperature superconductor (LTS)-based systems. It then describes the present status of superconducting cable technology and summarizes some of the major programs around the world. Whereas power cables may be thought of as a replacement for conventional power system components, \\{FCLs\\} and fault current controllers (FCC) have no conventional equivalent in the power grid. Several conceptually different FCL designs are described. The status of their development and installation on the power grid are described.

W. Hassenzahl

2013-01-01T23:59:59.000Z

368

First pass cable artefact correction for cardiac C-arm CT imaging  

Science Journals Connector (OSTI)

Cardiac C-arm CT imaging delivers a tomographic region-of-interest reconstruction of the patient's heart during image guided catheter interventions. Due to the limited size of the flat detector a volume image is reconstructed, which is truncated in the cone-beam (along the patient axis) and the fan-beam (in the transaxial plane) direction. To practically address this local tomography problem correction methods, like projection extension, are available for first pass image reconstruction. For second pass correction methods, like metal artefact reduction, alternative correction schemes are required when the field of view is limited to a region-of-interest of the patient. In classical CT imaging metal artefacts are corrected by metal identification in a first volume reconstruction and generation of a corrected projection data set followed by a second reconstruction. This approach fails when the metal structures are located outside the reconstruction field of view. When a C-arm CT is performed during a cardiac intervention pacing leads and other cables are frequently positioned on the patients skin, which results in propagating streak artefacts in the reconstruction volume. A first pass approach to reduce this type of artefact is introduced and evaluated here. It makes use of the fact that the projected position of objects outside the reconstruction volume changes with the projection perspective. It is shown that projection based identification, tracking and removal of high contrast structures like cables, only detected in a subset of the projections, delivers a more consistent reconstruction volume with reduced artefact level. The method is quantitatively evaluated based on 50 simulations using cardiac CT data sets with variable cable positioning. These data sets are forward projected using a C-arm CT system geometry and generate artefacts comparable to those observed in clinical cardiac C-arm CT acquisitions. A C-arm CT simulation of every cardiac CT data set without cables served as a ground truth. The 3D root mean square deviation between the simulated data set with and without cables could be reduced for 96% of the simulated cases by an average of 37% (min ?9%, max 73%) when using the first pass correction method. In addition, image quality improvement is demonstrated for clinical whole heart C-arm CT data sets when the cable removal algorithm was applied.

C Haase; D Schäfer; M Kim; S J Chen; J D Carroll; P Eshuis; O Dössel; M Grass

2014-01-01T23:59:59.000Z

369

Field test of liquid nitrogen cooled cryogenic power cable  

Science Journals Connector (OSTI)

A liquid nitrogen cooled cryogenic cable, 66 kV, 100 MVA, 30 m was constructed and tested with loads simulating actual operating loads from October 1970 to December 1971. The successful operation of the cable makes us hopeful it can be used for large capacity transmission. Our test line is composed of aluminium stranded hollow conductor, liquid-nitrogen impregnated polyethylene paper electrical insulation, and polyurethane foam thermal insulation.

H. Nagano; M. Fukasawa; S. Kuma; K. Sugiyama

1973-01-01T23:59:59.000Z

370

Experimental Researches on the Transmission of Electric Signals Through Submarine Cables. Part I. Laws of Transmission through Various Lengths of One Cable  

Science Journals Connector (OSTI)

...research-article Experimental Researches on the Transmission of Electric Signals Through Submarine Cables. Part I. Laws of Transmission through Various Lengths of One Cable Fleeming Jenkin The Royal Society is collaborating with JSTOR to digitize, preserve...

1862-01-01T23:59:59.000Z

371

Consider a thin coaxial cable of length L . We consider only TEM modes inside the cable, so that the photons may be considered as particles moving in one dimension, with  

E-Print Network (OSTI)

Consider a thin coaxial cable of length L . We consider only TEM modes inside the cable, so/sc = ļæ½ is the speed of light inside the cable. The temperature of the cable is T and the photons are in thermal equilibrium. The ends of the cable are terminated by plugs with zero resistance, such that the electric field

Ha, Taekjip

372

Design and applications of a flicker voltage generator  

SciTech Connect

In this paper, a 200W flicker voltage generator is made by using microcomputers and linear amplification circuits. The modulation amplitudes and frequencies based on the UIE {Delta}V{sub 10} evaluation can be arbitrarily assigned by software with high accuracy. The flicker voltage signals measured at the customer side also can be re-generated. Some applications, such as evaluating the effects of flicker voltage on incandescent and compact fluorescent lamps (CFLs), are also made. From experimental tests by use of the flicker voltage generator, the properties of some compact fluorescent lamps and incandescent lamps are compared. Those properties describe the relation between input voltage variation and output flux of lamps, such that there is direct description of influences of flicker voltages on lamps.

Chang, W.N.; Wu, C.J. [National Taiwan Inst. of Tech., Peitow-Taipei (Taiwan, Province of China). Dept. of Electrical Engineering

1995-12-31T23:59:59.000Z

373

Planning of distribution networks for medium voltage and low voltage.  

E-Print Network (OSTI)

??Determination of the placement and rating of transformers and feeders are the main objective of the basic distribution network planning. The bus voltage and the… (more)

Ziari, Iman

2011-01-01T23:59:59.000Z

374

Triple voltage dc-to-dc converter and method  

DOE Patents (OSTI)

A circuit and method of providing three dc voltage buses and transforming power between a low voltage dc converter and a high voltage dc converter, by coupling a primary dc power circuit and a secondary dc power circuit through an isolation transformer; providing the gating signals to power semiconductor switches in the primary and secondary circuits to control power flow between the primary and secondary circuits and by controlling a phase shift between the primary voltage and the secondary voltage. The primary dc power circuit and the secondary dc power circuit each further comprising at least two tank capacitances arranged in series as a tank leg, at least two resonant switching devices arranged in series with each other and arranged in parallel with the tank leg, and at least one voltage source arranged in parallel with the tank leg and the resonant switching devices, said resonant switching devices including power semiconductor switches that are operated by gating signals. Additional embodiments having a center-tapped battery on the low voltage side and a plurality of modules on both the low voltage side and the high voltage side are also disclosed for the purpose of reducing ripple current and for reducing the size of the components.

Su, Gui-Jia (Knoxville, TN)

2008-08-05T23:59:59.000Z

375

REFINED RFP LOOP VOLTAGE CALCULATION J.C. Sprott  

E-Print Network (OSTI)

is the stored magnetic energy, Up is the plasma energy, and 'E is the global energy confinement time, which-of-merit for RFP devices is the loop voltage. Low loop voltage implies high plasma temperature and long energy is smallest if the loop is as close to the outside of the shell and as far from the primary windings

Sprott, Julien Clinton

376

Intrinsic Surface Stability in LiMn2-xNix04-s (x = 0.45, 0.5) High Voltage Spinel Materials for Lithium Ion Batteries  

SciTech Connect

This work reports the surface stability of the high vollage Li ion cathode LiMn2_,Ni,Ooh\\ (x = 0.5, 0.45) by comparing thin fi lm and powder composite electrodes after cycling using X-ray photoelectron spectroscopy. The thin film electrodes offer the abili ty to probe the surface of the material without the need of a conductive agent and polymer binder typically used in composite electrodes. The resulls suggest that neither oxidation of PP6 to POF3 nor the decomposition of ethylene carbonate or dimethylene carbonate occurs on the surface of the spinel material. These resulls confirm the enhanced cycling stability and rate capability associated with the high vollage spinel material and suggests that the SE!IIayer fonns due to the reaction of electrochemically inactive components in composite electrodes with the electrolyte.

Carroll, Kyler J [University of California, San Diego; Yang, Ming-Che [University of Florida, Gainesville; Veith, Gabriel M [ORNL; Dudney, Nancy J [ORNL; Meng, Ying Shirley [University of California, San Diego

2012-01-01T23:59:59.000Z

377

Armor corrosion monitoring of a submarine AC cable  

SciTech Connect

After the hurricane Gilberto flattened (devastated) Cancun in September 1988, the submarine cables which supplied electricity to Isla Mjueres Island remained very damaged, and it was decided to install the new ones. In 1989, four new submarine cables were installed from Punta Sam, Cancun to Isla Mujeres. Such cables, of nominal tension 34.5 KV, were manufactures with a galvanized steel armor coated with asphalt, and began operation during 1990. The object of this communication is to present the experimental procedure that gave place to the armor corrosion monitoring procedure carried out in this particular case and to compare the results with those obtained on the field. Results of the cathodic protection system applied are also presented.

Genesca, J. [Univ. Nacional Autonoma de Mexico (Mexico). Dept. Ingenieria Metalurgica; Perez, T. [Univ. Autonoma de Campeche (Mexico). Programa Corrosion del Golfo de Mexico; Lara, C. [CFE-LAPEM, Irapuato (Mexico)

1997-12-01T23:59:59.000Z

378

Apparatus producing constant cable tension for intermittent demand  

DOE Patents (OSTI)

The disclosed apparatus produces constant tension in superconducting electrical cable, or some other strand, under conditions of intermittent demand, as the cable is unreeled from a reel or reeled thereon. The apparatus comprises a pivotally supported swing frame on which the reel is rotatably supported, a rotary motor, a drive train connected between the motor and the reel and including an electrically controllable variable torque slip clutch, a servo transducer connected to the swing frame for producing servo input signals corresponding to the position thereof, a servo control system connected between the transducer and the clutch for regulating the torque transmitted by the clutch to maintain the swing frame in a predetermined position, at least one air cylinder connected to the swing frame for counteracting the tension in the cable, and pressure regulating means for supplying a constant air pressure to the cylinder to establish the constant tension in the cable, the servo system and the clutch being effective to produce torque on the reel in an amount sufficient to provide tension in the cable corresponding to the constant force exerted by the air cylinder. The drive train also preferably includes a fail-safe brake operable to its released position by electrical power in common with the servo system, for preventing rotation of the reel if there is a power failure. A shock absorber and biasing springs may also be connected to the swing frame, such springs biasing the frame toward its predetermined position. The tension in the cable may be measured by force measuring devices engageable with the bearings for the reel shaft, such bearings being supported for slight lateral movement. The reel shaft is driven by a Shmidt coupler which accommodates such movement.

Lauritzen, Ted (Lafayette, CA)

1985-01-01T23:59:59.000Z

379

New protection method for HVDC lines including cables  

SciTech Connect

For the third project of the Hokkaido-Honshu HVDC Link in Japan, called the HVDC Link III project (rated at 250 kVdc-1,200 A-300 MW), the authors developed an HVDC transmission line protection method based on a new working principle that allows high-speed and highly sensitive detection of faults, enhancing reliability in the supply of electric power. In general, increasing the sensitivity of relays will lead to an increased likelihood of undesired operation whereas lowering the sensitivity will impair the responsiveness of the relays. The proposed method meets these apparently incompatible requirements very well. Basically classified as a differential scheme, the HVDC transmission line protection method compensates for a charging and discharging current that flows through the line-to-ground capacitance at times of voltage variations caused by a line fault or by the operation of dc power systems. The developed protection method is also characterized in that it uses current changes induced by voltage variations to restrain the operation of a relay. This configuration has made the proposed method far superior in responsiveness and sensitivity to the conventional protection method. A simulation using an EMTP (Electro-Magnetic Transients Program) was conducted on this method. Developed relay equipment embodying the new protection method was subjected to various verification tests, where this equipment was connected to a power system simulator, before being delivered to the HVDC Link III facility.

Takeda, H.; Ayakawa, H.; Tsumenaga, N.; Sanpei, M.

1995-10-01T23:59:59.000Z

380

LM139/LM239/LM339/LM2901/LM3302 Low Power Low Offset Voltage Quad Comparators  

E-Print Network (OSTI)

LM139/LM239/LM339/LM2901/LM3302 Low Power Low Offset Voltage Quad Comparators General Description The LM139 series consists of four independent precision voltage comparators with an offset voltage clock timers; multivibrators and high voltage digital logic gates. The LM139 series was designed

Lanterman, Aaron

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

TESTING AND EVALUATION OF SUPERCONDUCTING CABLES FOR THE LHC.  

SciTech Connect

As one of the activities of the US-LHC Accelerator Project, BNL is testing short samples of superconducting cables that will be used in the main LHC dipoles and quadrupoles. The purpose of these tests is to verify that the reels of superconducting cables as supplied by the vendors meet the required critical current specifications. The short-sample testing facility and the computer-assisted testing techniques for acquiring the data will be described. We also describe the data analysis, data storage, and data transmission methods.

THOMAS,R.; GHOSH,A.; MCCHESNEY,D.; JAIN,A.

1999-03-29T23:59:59.000Z

382

Amendment to LM-07-12 for Fiber Optic Cable Trenching at the...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Amendment to LM-07-12 for Fiber Optic Cable Trenching at the Westminster, Colorado, Office Amendment to LM-07-12 for Fiber Optic Cable Trenching at the Westminster, Colorado,...

383

Steady-State Heat Transfer in He II through Porous Superconducting Cable Insulation  

Science Journals Connector (OSTI)

The LHC program includes the study of thermal behavior of the superconducting cables wound in the dipole magnet cooled by superfluid helium (He II). Insulation of these superconducting cables forms the major ... ...

B. J. P. Baudouy; F.-P. Juster; C. Meuris…

1996-01-01T23:59:59.000Z

384

Near field coupling to shielded cable due to switching operation in substation  

Science Journals Connector (OSTI)

It is vital to study the electromagnetic coupling to shielded cable for improving electromagnetic antiinterference ability of secondary equipment in a substation. As a hybrid of method of moment ... shielded cabl...

Lei Qi; Xiang Cui

2008-09-01T23:59:59.000Z

385

ETM (Distribution Network Automation on 10 kV cable line stations...  

Open Energy Info (EERE)

ETM (Distribution Network Automation on 10 kV cable line stations) (Smart Grid Project) Jump to: navigation, search Project Name ETM (Distribution Network Automation on 10 kV cable...

386

Measurement of distributed strain due to laying and recovery of submarine optical fiber cable  

Science Journals Connector (OSTI)

Strain distribution due to cable laying and recovery is measured, using Brillouin optical fiber time domain analysis in a 3.7-km long submarine optical fiber cable. We believe this is...

Kurashima, Toshio; Horiguchi, Tsuneo; Yoshizawa, Nobuyuki; Tada, Hidenobu; Tateda, Mitsuhiro

1991-01-01T23:59:59.000Z

387

Aalborg Universitet Line Differential Protection Scheme Modelling for Underground 420 kV Cable Systems  

E-Print Network (OSTI)

system transients, transmission cable systems, protection and HVDC-VSC. E-mail: clb@et.aau.dk. desired

Bak, Claus Leth

388

Low voltage nonprimary explosive detonator  

DOE Patents (OSTI)

A low voltage, electrically actuated, nonprimary explosive detonator is disclosed wherein said detonation is achieved by means of an explosive train in which a deflagration-to-detonation transition is made to occur. The explosive train is confined within a cylindrical body and positioned adjacent to low voltage ignition means have electrical leads extending outwardly from the cylindrical confining body. Application of a low voltage current to the electrical leads ignites a self-sustained deflagration in a donor portion of the explosive train which then is made to undergo a transition to detonation further down the train.

Dinegar, Robert H. (Los Alamos, NM); Kirkham, John (Newbury, GB2)

1982-01-01T23:59:59.000Z

389

Electromagnetic interference with electronic apparatus by switching surges in GIS-cable system  

SciTech Connect

Thyristor malignitions and protector relay failures caused by GCB closing in the GIS of a cable system could not be controlled by reducing the ground impedance or adding surge absorbing capacitors. As a result, a study was carried out on this problem with a 66kV mock-up apparatus installed in a factory. It was found that malignitions and failures such as mentioned above could be controlled by preventing 10MHz ultra high-frequency surges emitted by the GIS from leaking out into the grounding system.

Nishiwaki, S.; Nojima, K.; Tatara, S.; Kosakada, M.; Tanabe, N.; Yanabu, S. [Toshiba Corp., Kawasaki (Japan)] [Toshiba Corp., Kawasaki (Japan)

1995-04-01T23:59:59.000Z

390

PARTIAL DISCHARGE TESTING OF DEFECTIVE THREE-PHASE PILC CABLE UNDER RATED CONDITIONS  

E-Print Network (OSTI)

PARTIAL DISCHARGE TESTING OF DEFECTIVE THREE-PHASE PILC CABLE UNDER RATED CONDITIONS J. A. Hunter 1 lifespan. An increase in the failure rates of paper insulated lead covered (PILC) cables that make up is to document the effects of mechanical stress on the generation of partial discharge (PD) for cables of PILC

Southampton, University of

391

Communications Copper Horizontal Cable 27 15 13-1 SECTION 27 15 13  

E-Print Network (OSTI)

Communications Copper Horizontal Cable 27 15 13-1 SECTION 27 15 13 COMMUNICATIONS COPPER HORIZONTAL of category copper horizontal cable. B. The cable performance (category 5e, category 6A) shall be as specified 20 Copper Testing 5. 27 11 19 Communications Terminations Blocks and Patch Panels 6. 27 15 43

Dawson, Clint N.

392

Defining potential mechanisms by which Cables is lost in ovarian cancer  

Science Journals Connector (OSTI)

...Defining potential mechanisms by which Cables is lost in ovarian cancer Sakamoto Hideo...Assoc Cancer Res, Volume 47, 2006] 1547 Cables is a novel cyclin-dependent kinase...maps to human chromosome 18q11-12. Cables appears to be primarily involved in cell...

Sakamoto Hideo; Rosemary Foster; Michael V. Seiden; Esther Oliva; Daniel C. Chung; Maureen P. Lynch; Lawrence R. Zukerberg; Bo R. Rueda

2006-04-15T23:59:59.000Z

393

The writhing of circular cross–section rods: undersea cables to DNA supercoils  

Science Journals Connector (OSTI)

...circular cross-section rods: undersea cables to DNA supercoils D. M. Stump 1 W...tension and torque, such as undersea cables, and to closed loops with inserted twist...circular cross-section rods: undersea cables to DNA supercoils By D. M. Stump1...

1998-01-01T23:59:59.000Z

394

Finite Element Analysis of TDR Cable-Grout-Soil Mass Interaction During Localized Shearing  

E-Print Network (OSTI)

1 Finite Element Analysis of TDR Cable-Grout-Soil Mass Interaction During Localized Shearing By J and laboratory measurement of Time Domain Reflectometry (TDR) cable-grout response to analyze the interaction between the cable, grout, and surrounding soil mass during localized shearing. Finite element (FE) model

395

Cable-Piliated Burkholderia cepaciaBinds to Cytokeratin 13 of Epithelial Cells  

Science Journals Connector (OSTI)

...ARTICLE MOLECULAR AND CELLULAR PATHOGENESIS Cable-Piliated Burkholderia cepacia Binds to...Canada. This strain expresses surface cable (Cbl) pili and is thought to be the major...epithelial cell (BEC) protein that binds cable pilus-positive B. cepacia. N-terminal...

Umadevi S. Sajjan; Francisco A. Sylvester; Janet F. Forstner

2000-04-01T23:59:59.000Z

396

Superconducting Cables for a.c. and d.c. Power Transmission  

Science Journals Connector (OSTI)

...1973 research-article Superconducting Cables for a.c. and d.c. Power Transmission...power transmission lines. Some present cables are water cooled to increase their current...both a.c. and d.c. superconducting cables are described, with particular attention...

1973-01-01T23:59:59.000Z

397

Effort on Developing Cabled Ocean Observatories Research Assitant, Institute of Mechatronics Control Engineering, Zhejiang University  

E-Print Network (OSTI)

Effort on Developing Cabled Ocean Observatories in China Yanhu Chen Research Assitant, Institute and Resources Engineering, University of Hawaii Abstract Cabled ocean observatory that enables abundant power cabled ocean observatories to support ocean scientific research in China, Zhejiang University has been

Frandsen, Jannette B.

398

Cables 1 gene inactivation is associated with human ovarian cancer development  

Science Journals Connector (OSTI)

...Apr 14-18, 2007; Los Angeles, CA Cables 1 gene inactivation is associated with...14-18, 2007; Los Angeles, CA 3682 Cables 1 is a cyclin-dependent kinase binding...regulation and cell proliferation. Loss of Cables 1 expression is observed in many human...

Hideo Sakamoto; Anne Friel; Lankai Guo; Ana Ilic; Michael Seiden; Maureen Lynch; Rosemary Foster; Lawrence Zukerberg; Bo Rueda

2007-05-01T23:59:59.000Z

399

Langmuir probe measurements in a time-fluctuating-highly ionized non-equilibrium cutting arc: Analysis of the electron retarding part of the time-averaged current-voltage characteristic of the probe  

SciTech Connect

This work describes the application of Langmuir probe diagnostics to the measurement of the electron temperature in a time-fluctuating-highly ionized, non-equilibrium cutting arc. The electron retarding part of the time-averaged current-voltage characteristic of the probe was analysed, assuming that the standard exponential expression describing the electron current to the probe in collision-free plasmas can be applied under the investigated conditions. A procedure is described which allows the determination of the errors introduced in time-averaged probe data due to small-amplitude plasma fluctuations. It was found that the experimental points can be gathered into two well defined groups allowing defining two quite different averaged electron temperature values. In the low-current region the averaged characteristic was not significantly disturbed by the fluctuations and can reliably be used to obtain the actual value of the averaged electron temperature. In particular, an averaged electron temperature of 0.98 ± 0.07 eV (= 11400 ± 800 K) was found for the central core of the arc (30 A) at 3.5 mm downstream from the nozzle exit. This average included not only a time-average over the time fluctuations but also a spatial-average along the probe collecting length. The fitting of the high-current region of the characteristic using such electron temperature value together with the corrections given by the fluctuation analysis showed a relevant departure of local thermal equilibrium in the arc core.

Prevosto, L.; Mancinelli, B. [Grupo de Descargas Eléctricas, Departamento Ing. Electromecįnica, Facultad Regional Venado Tuerto (UTN), Laprida 651, Venado Tuerto (2600) Santa Fe (Argentina)] [Grupo de Descargas Eléctricas, Departamento Ing. Electromecįnica, Facultad Regional Venado Tuerto (UTN), Laprida 651, Venado Tuerto (2600) Santa Fe (Argentina); Kelly, H. [Grupo de Descargas Eléctricas, Departamento Ing. Electromecįnica, Facultad Regional Venado Tuerto (UTN), Laprida 651, Venado Tuerto (2600) Santa Fe (Argentina) [Grupo de Descargas Eléctricas, Departamento Ing. Electromecįnica, Facultad Regional Venado Tuerto (UTN), Laprida 651, Venado Tuerto (2600) Santa Fe (Argentina); Instituto de Fķsica del Plasma (CONICET), Departamento de Fķsica, Facultad de Ciencias Exactas y Naturales (UBA) Ciudad Universitaria Pab. I, 1428 Buenos Aires (Argentina)

2013-12-15T23:59:59.000Z

400

DSP IMPLEMENTATION OF DC VOLTAGE REGULATION USING ADAPTIVE CONTROL FOR 200 KW 62000 RPM  

E-Print Network (OSTI)

to control the DC voltage for 200 kW induction generator rated at a speed of 62000 RPM under different load to regulate the DC voltage for high speed induction generators rated from 5 kW to 200 kW. ii #12DSP IMPLEMENTATION OF DC VOLTAGE REGULATION USING ADAPTIVE CONTROL FOR 200 KW 62000 RPM INDUCTION

Wu, Thomas

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Definition: Automated Voltage Regulators | Open Energy Information  

Open Energy Info (EERE)

Regulators Regulators Jump to: navigation, search Dictionary.png Automated Voltage Regulators Voltage regulators are transformers that can increase or decrease the voltage on a distribution circuit to help keep the voltage within a pre-determined band. Unlike capacitor banks, voltage regulators cannot adjust power factor. These devices typically monitor the voltage at the location where they are connected, and compare it to a programmed set point. If the voltage deviates too far from the set point, the voltage regulator can increase or decrease its output voltage by moving the tap on the secondary side up or down. An automated voltage regulator can operate with remote control signals, or in concert with other area voltage control devices, to help regulate distribution voltage in a coordinated fashion.

402

Large deflection of cantilever rod pulled by cable  

Science Journals Connector (OSTI)

Abstract The large deflection of an elastic cantilever rod pulled by cable is analyzing in terms of the Jacobi elliptical functions. The problem is reduced to solution of a system of two transcendental equations which allow defining six different problems. All these problems are discussions and illustrated with graphs of equilibrium shapes and tables providing some reference numerical values.

Milan Batista

2014-01-01T23:59:59.000Z

403

Saving Megawatts with Voltage Optimization  

E-Print Network (OSTI)

that had been installed at several electric utility distribution substations in the U.S. and Canada. These systems, being operated in Conservation Voltage Regulation mode, have provided significant energy conservation where they have been installed...

Wilson, T.; Bell, D.

2010-01-01T23:59:59.000Z

404

Multipoint Pressure and Temperature Sensing Fiber Optic Cable for Monitoring CO2 Sequestration  

SciTech Connect

This report describes the work completed on contract DE-FE0010116. The goal of this two year project was to develop and demonstrate in the laboratory a highly accurate multi-point pressure measurement fiber optic cable based on MEMS pressure sensors suitable for downhole deployment in a CO2 sequestration well. The sensor interrogator was also to be demonstrated in a remote monitoring system and environmental testing was to be completed to indicate its downhole survivability over a lengthy period of time (e.g., 20 years). An interrogator system based on a pulsed laser excitation was shown to be capable of multiple (potentially 100+) simultaneous sensor measurements. Two sensors packages were completed and spliced in a cable onto the same fiber and measured. One sensor package was subsequently measured at high temperatures and pressures in supercritical CO2, while the other package was measured prior and after being subjected to high torque stresses to mimic downhole deployment. The environmental and stress tests indicated areas in which the package design should be further improved.

Challener, William

2014-12-31T23:59:59.000Z

405

Superconducting Fault Current Limiter for Transmission Voltage  

Science Journals Connector (OSTI)

Within a collaboration of American Superconductor, Siemens, Nexans and Southern California Edison one electrical phase of a resistive superconducting fault current limiter for the 115 kV transmission voltage level has been designed and manufactured. The active part of the limiter consists of 63 bifilar coils made of 12 mm wide steel-stabilized YBCO conductor and is housed in a cryostat operated at 5 bar and 74 K. The first phase was completely assembled and successfully subjected to power switching tests and high voltage tests. The basic design of the system and the test results are reported. The work was funded in part by US-DOE under Contract Number DE-FC26-07NT43243.

Hans-Peter Kraemer; Wolfgang Schmidt; Hong Cai; Bruce Gamble; David Madura; Tim MacDonald; Joe McNamara; Walther Romanosky; Greg Snitchler; Nicolas Lallouet; Frank Schmidt; Syed Ahmed

2012-01-01T23:59:59.000Z

406

Ac loss reduction of multilayer superconducting power transmission cables by using narrow  

Science Journals Connector (OSTI)

The ac loss characteristics of coated conductors are dominated by the magnetic field component normal to their superconductor layer. Multilayer cables as well as monolayer cables consisting of 4 mm-wide coated conductors (named 4 mm cables) and those consisting of 2 mm-wide coated conductors (named 2 mm cables) were designed, and numerical electromagnetic field analyses were performed in their cross sections to calculate their ac losses. Trapezoidal lateral critical current density Jc distributions with shoulders as well as uniform ones were assumed in coated conductors for the analyses. The former models the degraded Jc near the edges of coated conductors. In the case of the monolayer, the calculated ac losses of the 2 mm cables were comparable to those of the 4 mm cables. In the cases of the multilayers, the calculated ac losses of the 2 mm cables were obviously less than those of the 4 mm cables. The degraded Jc near the edges of coated conductors more seriously affects the ac loss characteristics of the 2 mm cables than those of the 4 mm cables. However, even if we consider the influence of the degraded Jc near the edges of coated conductors, 2 mm-wide coated conductors are more profitable than 4 mm-wide coated conductors in multilayer cables from the viewpoint of ac loss reduction.

Naoyuki Amemiya; Quan Li; Kaoru Ito; Katsutoku Takeuchi; Taketsune Nakamura; Takeshi Okuma

2011-01-01T23:59:59.000Z

407

AC loss characteristics of superconducting power transmission cables: gap effect and  

Science Journals Connector (OSTI)

Four groups of superconducting power transmission cables composed of coated conductors with 4.0 mm width and 2 µm superconductor thickness have been designed, including mono-layer, two-layer, four-layer and six-layer cables. In each group, three types of cables have been constructed with gaps of different size between adjacent coated conductors, which are classified into small gap, medium gap and large gap. Moreover, different lateral critical current density (Jc) distributions, specifically a uniform distribution and a trapezoidal distribution with a sloping shoulder, have been assumed while calculating the AC losses of these cables numerically by using a one-dimensional FEM model. Numerical results show that AC losses in mono-layer cables are significantly influenced by gaps between coated conductors as well as lateral Jc distribution, while cables with many layers are hardly affected by them. This proves that small gaps between coated conductors are not absolutely essential to reduce AC losses in multi-layer cables, and a sloping shoulder of the Jc distribution is more allowable in multi-layer cables than in mono-layer cables. The AC loss distributions among layers in six-layer cables are presented and the reasons for different influences of the gap as well as the lateral Jc distribution in mono-layer and multi-layer cables are discussed.

Quan Li; Naoyuki Amemiya; Katsutoku Takeuchi; Taketsune Nakamura; Noboru Fujiwara

2010-01-01T23:59:59.000Z

408

Optically initiated silicon carbide high voltage switch  

DOE Patents (OSTI)

An improved photoconductive switch having a SiC or other wide band gap substrate material, such as GaAs and field-grading liners composed of preferably SiN formed on the substrate adjacent the electrode perimeters or adjacent the substrate perimeters for grading the electric fields.

Caporaso, George J. (Livermore, CA); Sampayan, Stephen E. (Manteca, CA); Sullivan, James S. (Livermore, CA); Sanders; David M. (Livermore, CA)

2011-02-22T23:59:59.000Z

409

HIGH-VOLTAGE SPINEL AND POLYANION CATHODES  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

POLYANION CATHODES ARUMUGAM MANTHIRAM Electrochemical Energy Laboratory (ECEL) Materials Science and Engineering Program The University of Texas at Austin May 14, 2012 Project ID...

410

Lockout device for high voltage circuit breaker  

SciTech Connect

An improved lockout assembly is provided for a circuit breaker to lock the switch handle into a selected switch position. The lockout assembly includes two main elements, each having a respective foot for engaging a portion of the upper housing wall of the circuit breaker. The first foot is inserted into a groove in the upper housing wall, and the second foot is inserted into an adjacent aperture (e.g., a slot) in the upper housing wall. The first foot is slid under and into engagement with a first portion, and the second foot is slid under and into engagement with a second portion of the upper housing wall. At the same time the respective two feet are placed in engagement with the respective portions of the upper housing wall, two holes, one on each of the respective two main elements of the assembly, are placed in registration; and a locking device, such as a special scissors equipped with a padlock, is installed through the registered holes to secure the lockout assembly on the circuit breaker. When the lockout assembly of the invention is secured on the circuit breaker, the switch handle of the circuit breaker is locked into the selected switch position and prevented from being switched to another switch position.

Kozlowski, L.J.; Shirey, L.A.

1993-01-26T23:59:59.000Z

411

Lockout device for high voltage circuit breaker  

DOE Patents (OSTI)

An improved lockout assembly is provided for a circuit breaker to lock the switch handle into a selected switch position. The lockout assembly includes two main elements, each having a respective foot for engaging a portion of the upper housing wall of the circuit breaker. The first foot is inserted into a groove in the upper housing wall, and the second foot is inserted into an adjacent aperture (e.g., a slot) in the upper housing wall. The first foot is slid under and into engagement with a first portion, and the second foot is slid under and into engagement with a second portion of the upper housing wall. At the same time the repsective two feet are placed in engagement with the respective portions of the upper housing wall, two holes, one on each of the respective two main elements of the assembly, are placed in registration; and a locking device, such as a special scissors equipped with a padlock, is installed through the registered holes to secure the lockout assembly on the circuit breaker. When the lockout assembly of the invention is secured on the circuit breaker, the switch handle of the circuit breaker is locked into the selected switch position and prevented from being switched to another switch position.

Kozlowski, Lawrence J. (New Kensington, PA); Shirey, Lawrence A. (North Huntingdon, PA)

1993-01-01T23:59:59.000Z

412

Lookout device for high voltage circuit breaker  

SciTech Connect

An improved lockout assembly is provided for a circuit breaker to lock the switch handle into a selected switch position. The lockout assembly includes two main elements, each having a respective foot for engaging a portion of the upper housing wall of the circuit breaker. The first foot is inserted into a groove in the upper housing wall, and the second foot is inserted into an adjacent aperture (e.g., a slot) in the upper housing wall. The first foot is slid under and into engagement with a first portion, and the second foot is slid under and into engagement with a second portion of the upper housing wall. At the same time the respective two feet are placed in engagement with the respective portions of the upper housing wall, two holes, one on each of the respective two main elements of the assembly, are placed in registration; and a locking device, such as a special scissors equipped with a padlock, is installed through the registered holes to secure the lockout assembly on the circuit breaker. When the lockout assembly of the invention is secured on the circuit breaker, the switch handle of the circuit breaker is locked into the selected switch position and prevented from being switched to another switch position.

Kozlowski, L.J.; Shirey, L.A.

1991-12-31T23:59:59.000Z

413

High Voltage Power Supply Capacitor Problem Analysis  

E-Print Network (OSTI)

evidence of pits on the surface. One pit showed evidence that the silver had burned thru. It was concluded this was the shorted area.. A microsection of the capacitor (see photomicrograph #1} shows a pit in the dielectric material. Photomicrograph #2 shows another pit in the same capacitor. 2. 3 A total of eighteen capacitors

Rathbun, Julie A.

414

Production of high voltage by ion bombardment  

E-Print Network (OSTI)

E-08 2000 0. 511 1999. 489 5. 120E-08 0. 539 1999. 461 5. 401E-08 2500 O. B39 2499. 361 6. 403E-DB 0. 675 2499. 325 6. 764E-DB 3000 0. 769 2999. 231 7. 705E-OB 0. 810 2999. 190 8. 116E-OB 3500 0. 899 3499. 101 9. 008E-OB 0. 948 3499. 054 9. 479E...E-08 2000 0. 511 1999. 489 5. 120E-08 0. 539 1999. 461 5. 401E-08 2500 O. B39 2499. 361 6. 403E-DB 0. 675 2499. 325 6. 764E-DB 3000 0. 769 2999. 231 7. 705E-OB 0. 810 2999. 190 8. 116E-OB 3500 0. 899 3499. 101 9. 008E-OB 0. 948 3499. 054 9. 479E...

Phinney, Lucas Carter

2012-06-07T23:59:59.000Z

415

HIGH-VOLTAGE SPINEL AND POLYANION CATHODES  

Energy.gov (U.S. Department of Energy (DOE))

2012 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

416

High Voltage Electrolyte for Lithium Batteries  

Energy.gov (U.S. Department of Energy (DOE))

2012 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

417

High voltage photo switch package module  

DOE Patents (OSTI)

A photo-conductive switch package module having a photo-conductive substrate or wafer with opposing electrode-interface surfaces, and at least one light-input surface. First metallic layers are formed on the electrode-interface surfaces, and one or more optical waveguides having input and output ends are bonded to the substrate so that the output end of each waveguide is bonded to a corresponding one of the light-input surfaces of the photo-conductive substrate. This forms a waveguide-substrate interface for coupling light into the photo-conductive wafer. A dielectric material such as epoxy is then used to encapsulate the photo-conductive substrate and optical waveguide so that only the metallic layers and the input end of the optical waveguide are exposed. Second metallic layers are then formed on the first metallic layers so that the waveguide-substrate interface is positioned under the second metallic layers.

Sullivan, James S; Sanders, David M; Hawkins, Steven A; Sampayan, Stephen E

2014-02-18T23:59:59.000Z

418

High-voltage-compatible, fully depleted CCDs  

E-Print Network (OSTI)

B. Flaugher, “The dark energy survey,” Inter. J. of ModernTelescope (LSST), 1 the Dark Energy Survey camera, 2 the

2006-01-01T23:59:59.000Z

419

Electro-optic voltage sensor with Multiple Beam Splitting  

DOE Patents (OSTI)

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID)

2000-01-01T23:59:59.000Z

420

Electro-optic voltage sensor with beam splitting  

DOE Patents (OSTI)

The invention is a miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware typically found in the prior art. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID)

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Voltage, energy and power in electric circuits  

E-Print Network (OSTI)

Voltage, energy and power in electric circuits Science teaching unit #12;Disclaimer The Department-2008DVD-EN Voltage, energy and power in electric circuits #12;#12;Ā© Crown copyright 2008 1The National Strategies | Secondary Voltage, energy and power in electric circuits 00094-2008DVD-EN Contents Voltage

Berzins, M.

422

Electro-optic voltage sensor head  

DOE Patents (OSTI)

The invention is an electro-optic voltage sensor head designed for integration with existing types of high voltage transmission and distribution apparatus. The sensor head contains a transducer, which comprises a transducing material in which the Pockels electro-optic effect is observed. In the practice of the invention at least one beam of electromagnetic radiation is routed into the transducing material of the transducer in the sensor head. The beam undergoes an electro-optic effect in the sensor head when the transducing material is subjected to an E-field. The electro-optic effect is observed as a differential phase a shift, also called differential phase modulation, of the beam components in orthogonal planes of the electromagnetic radiation. In the preferred embodiment the beam is routed through the transducer along an initial axis and then reflected by a retro-reflector back substantially parallel to the initial axis, making a double pass through the transducer for increased measurement sensitivity. The preferred embodiment of the sensor head also includes a polarization state rotator and at least one beam splitter for orienting the beam along major and minor axes and for splitting the beam components into two signals which are independent converse amplitude-modulated signals carrying E-field magnitude and hence voltage information from the sensor head by way of optic fibers.

Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Woods, Gregory K. (Cornelius, OR)

1999-01-01T23:59:59.000Z

423

Ancillary service details: Voltage control  

SciTech Connect

Voltage control is accomplished by managing reactive power on an alternating-current power system. Reactive power can be produced and absorbed by both generation and transmission equipment. Reactive-power devices differ substantially in the magnitude and speed of response and in their capital costs. System operators, transmission owners, generators, customers, power marketers, and government regulators need to pay close attention to voltage control as they restructure the U.S. electricity industry. Voltage control can affect reliability and commerce in three ways: (1) Voltages must be maintained within an acceptable range for both customer and power-system equipment to function properly. (2) The movement of reactive power consumes transmission resources, which limits the ability to move real power and worsens congestion. (3) The movement of reactive power results in real-power losses. When generators are required to supply excessive amounts of reactive power, their real-power production must be curtailed. These opportunity costs are not currently compensated for in most regions. Current tariffs are based on embedded costs. These embedded-cost tariffs average about $0.51/MWh, equivalent to $1.5 billion annually for the United States as a whole. Although this cost is low when compared with the cost of energy, it still aggregates to a significant amount of money. This report takes a basic look at why the power system requires reactive power (an appendix explains the fundamentals of real and reactive power). The report then examines the various types of generation and transmission resources used to supply reactive power and to control voltage. Finally it discusses how these resources are deployed and paid for in several reliability regions around the country. As the U.S. electricity industry is restructured, the generation, transmission, and system-control equipment and functions that maintain voltages within the appropriate ranges are being deintegrated.

Kirby, B.; Hirst, E.

1997-12-01T23:59:59.000Z

424

Society of Cable Telecommunications Engineers | Open Energy Information  

Open Energy Info (EERE)

Cable Telecommunications Engineers Cable Telecommunications Engineers Jump to: navigation, search Logo: SCTE Name SCTE Address 140 Philips Rd Place Exton, Pennsylvania Zip 19341 Region Northeast - NY NJ CT PA Area Number of employees 11-50 Year founded 1969 Phone number 610-363-6888 Website http://www.scte.org/ Coordinates 40.0634614Ā°, -75.6439227Ā° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.0634614,"lon":-75.6439227,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

425

Electronic scraps - Recovering of valuable materials from parallel wire cables  

SciTech Connect

Every year, the number of discarded electro-electronic products is increasing. For this reason recycling is needed, to avoid wasting non-renewable natural resources. The objective of this work is to study the recycling of materials from parallel wire cable through unit operations of mineral processing. Parallel wire cables are basically composed of polymer and copper. The following unit operations were tested: grinding, size classification, dense medium separation, electrostatic separation, scrubbing, panning, and elutriation. It was observed that the operations used obtained copper and PVC concentrates with a low degree of cross contamination. It was concluded that total liberation of the materials was accomplished after grinding to less than 3 mm, using a cage mill. Separation using panning and elutriation presented the best results in terms of recovery and cross contamination.

Pinheiro Bezerra de Araujo, Mishene Christie [Department of Metallurgical and Materials Engineering, Escola Politecnica, University of Sao Paulo, Av Prof. Mello Moraes 2464, Sao Paulo 05508-900 (Brazil); Pinto Chaves, Arthur [Department of Mining and Petroleum Engineering, Escola Politecnica, University of Sao Paulo, Av Prof. Mello Moraes 2373, Sao Paulo 05508-900 (Brazil); Crocce Romano Espinosa, Denise [Department of Metallurgical and Materials Engineering, Escola Politecnica, University of Sao Paulo, Av Prof. Mello Moraes 2464, Sao Paulo 05508-900 (Brazil); Tenorio, Jorge Alberto Soares [Department of Metallurgical and Materials Engineering, Escola Politecnica, University of Sao Paulo, Av Prof. Mello Moraes 2464, Sao Paulo 05508-900 (Brazil)], E-mail: jtenorio@usp.br

2008-11-15T23:59:59.000Z

426

Cable Hot Shorts and Circuit Analysis in Fire Risk Assessment  

SciTech Connect

Under existing methods of probabilistic risk assessment (PRA), the analysis of fire-induced circuit faults has typically been conducted on a simplistic basis. In particular, those hot-short methodologies that have been applied remain controversial in regards to the scope of the assessments, the underlying methods, and the assumptions employed. To address weaknesses in fire PRA methodologies, the USNRC has initiated a fire risk analysis research program that includes a task for improving the tools for performing circuit analysis. The objective of this task is to obtain a better understanding of the mechanisms linking fire-induced cable damage to potentially risk-significant failure modes of power, control, and instrumentation cables. This paper discusses the current status of the circuit analysis task.

LaChance, Jeffrey; Nowlen, Steven P.; Wyant, Frank

1999-05-19T23:59:59.000Z

427

On the Relative Speed of the Electric Wave through Submarine Cables of Different Lengths, and a Unit of Speed for Comparing Electric Cables by Bisecting the Electric Wave.  

Science Journals Connector (OSTI)

...1862-1863 research-article On the Relative Speed of the Electric Wave through Submarine Cables of Different Lengths, and a Unit of Speed for Comparing Electric Cables by Bisecting the Electric Wave. Cromwell F. Varley The Royal Society is collaborating...

1862-01-01T23:59:59.000Z

428

Optical crystal based devices for current and voltage measurement  

SciTech Connect

A prerequisite for safe, stable operation of an electric power system is accurate, reliable measurement of the system parameters, in particular, current and voltage. Traditionally this has been achieved on High Voltage (HV) systems by expensive, bulky iron-cored current transformers (CTs) and capacitor voltage transformers (VTs). Both these devices are increasingly coming under review in modern power systems due to their cost, safety implications for personnel and surrounding plant if failure occurs, installation time and indeed substation land requirements. This paper describes novel designs for magneto-optic and electro-optic crystal sensors providing potentially separate and combined current and voltage measurement. The results of testing programs are presented and details of the work associated with field trials given.

Cruden, A.; Richardson, Z.J.; McDonald, J.R.; Andonovic, I. [Univ. of Strathclyde (United Kingdom)] [Univ. of Strathclyde (United Kingdom)

1995-07-01T23:59:59.000Z

429

Voltage Regulator Chip: Power Supplies on a Chip  

SciTech Connect

ADEPT Project: CPES at Virginia Tech is finding ways to save real estate on a computer's motherboard that could be used for other critical functions. Every computer processor today contains a voltage regulator that automatically maintains a constant level of electricity entering the device. These regulators contain bulky components and take up about 30% of a computer's motherboard. CPES at Virginia Tech is developing a voltage regulator that uses semiconductors made of gallium nitride on silicon (GaN-on-Si) and high-frequency soft magnetic material. These materials are integrated on a small, 3D chip that can handle the same amount of power as traditional voltage regulators at 1/10 the size and with improved efficiency. The small size also frees up to 90% of the motherboard space occupied by current voltage regulators.

None

2010-09-01T23:59:59.000Z

430

Noise-based wavelet denoising technique for partial discharge measurement  

Science Journals Connector (OSTI)

For enhancement the insulation quality of medium voltage and high voltage power cables, on-site partial discharge (PD) diagnosis tests such as detection, location and identification are used to find defects or faults and assess ageing degree of the cable ... Keywords: discrete wavelet transform, frequency-tuned resonance, oscilating voltage wave, partial discharge, power cables, very low frequency

Zhou-Sheng Zhang; Deng-Ming Xiao

2008-06-01T23:59:59.000Z

431

Current vs. Voltage Feedback Amplifiers  

E-Print Network (OSTI)

?' In most applications, the differences between current feedback (CFB) and voltage feedback (VFB) are not apparent. Today's CFB and VFB amplifiers have comparable performance, but there are cer- tain unique Performance Ā· Feedback Freedom Aside from the well-known attribute of CFB amplifiers, gain

Lanterman, Aaron

432

Determining Remaining Useful Life of Aging Cables in Nuclear Power Plants – Interim Study FY13  

SciTech Connect

The most important criterion for cable performance is its ability to withstand a design-basis accident. With nearly 1000 km of power, control, instrumentation, and other cables typically found in an NPP, it would be a significant undertaking to inspect all of the cables. Degradation of the cable jacket, electrical insulation, and other cable components is a key issue that is likely to affect the ability of the currently installed cables to operate safely and reliably for another 20 to 40 years beyond the initial operating life. The development of one or more nondestructive evaluation (NDE) techniques and supporting models that could assist in determining the remaining life expectancy of cables or their current degradation state would be of significant interest. The ability to nondestructively determine material and electrical properties of cable jackets and insulation without disturbing the cables or connections has been deemed essential. Currently, the only technique accepted by industry to measure cable elasticity (the gold standard for determining cable insulation degradation) is the indentation measurement. All other NDE techniques are used to find flaws in the cable and do not provide information to determine the current health or life expectancy. There is no single NDE technique that can satisfy all of the requirements needed for making a life-expectancy determination, but a wide range of methods have been evaluated for use in NPPs as part of a continuous evaluation program. The commonly used methods are indentation and visual inspection, but these are only suitable for easily accessible cables. Several NDE methodologies using electrical techniques are in use today for flaw detection but there are none that can predict the life of a cable. There are, however, several physical and chemical ptoperty changes in cable insulation as a result of thermal and radiation damage. In principle, these properties may be targets for advanced NDE methods to provide early warning of aging and degradation. Examples of such key indicators include changes in chemical structure, mechanical modulus, and dielectric permittivity. While some of these indicators are the basis of currently used technologies, there is a need to increase the volume of cable that may be inspected with a single measurement, and if possible, to develop techniques for in-situ inspection (i.e., while the cable is in operation). This is the focus of the present report.

Simmons, Kevin L.; Fifield, Leonard S.; Westman, Matthew P.; Ramuhalli, Pradeep; Pardini, Allan F.; Tedeschi, Jonathan R.; Jones, Anthony M.

2013-09-27T23:59:59.000Z

433

Circuit bridging of digital equipment caused by smoke from a cable fire  

SciTech Connect

Advanced reactor systems are likely to use protection systems with digital electronics that ideally should be resistant to environmental hazards, including smoke from possible cable fires. Previous smoke tests have shown that digital safety systems can fail even at relatively low levels of smoke density and that short-term failures are likely to be caused by circuit bridging. Experiments were performed to examine these failures, with a focus on component packaging and protection schemes. Circuit bridging, which causes increased leakage currents and arcs, was gauged by measuring leakage currents among the leads of component packages. The resistance among circuit leads typically varies over a wide range, depending on the nature of the circuitry between the pins, bias conditions, circuit board material, etc. Resistance between leads can be as low as 20 k{Omega} and still be good, depending on the component. For these tests, the authors chose a printed circuit board and components that normally have an interlead resistance above 10{sup 12} {Omega}, but if the circuit is exposed to smoke, circuit bridging causes the resistance to fall below 10{sup 3} {Omega}. Plated-through-hole (PTH) and surface-mounted (SMT) packages were exposed to a series of different smoke environments using a mixture of environmentally qualified cables for fuel. Conformal coatings and enclosures were tested as circuit protection methods. High fuel levels, high humidity, and high flaming burns were the conditions most likely to cause circuit bridging. The inexpensive conformal coating that was tested - an acrylic spray - reduced leakage currents, but enclosure in a chassis with a fan did not. PTH packages were more resistant to smoke-induced circuit bridging than SMT packages. Active components failed most often in tests where the leakage currents were high, but failure did not always accompany high leakage currents.

Tanaka, T.J.; Anderson, D.J.

1997-03-01T23:59:59.000Z

434

GRR/Section 7-HI-a - Geothermal and Cable System Development Permit | Open  

Open Energy Info (EERE)

GRR/Section 7-HI-a - Geothermal and Cable System Development Permit GRR/Section 7-HI-a - Geothermal and Cable System Development Permit < GRR Jump to: navigation, search GRR-logo.png GEOTHERMAL REGULATORY ROADMAP Roadmap Home Roadmap Help List of Sections Section 7-HI-a - Geothermal and Cable System Development Permit 07HIAGeothermalAndCableSystemDevelopmentPermitting.pdf Click to View Fullscreen Contact Agencies Hawaii Department of Land and Natural Resources Engineering Division Regulations & Policies Hawaii Revised Statute 196D Hawaii Administrative Rules 13-185 Hawaii Revised Statute 205-3.1 Revised Statute 205-5. Triggers None specified Click "Edit With Form" above to add content 07HIAGeothermalAndCableSystemDevelopmentPermitting.pdf 07HIAGeothermalAndCableSystemDevelopmentPermitting.pdf Error creating thumbnail: Page number not in range.

435

Decompression cooling system operation for HTS power cable in the KEPCO power grid  

Science Journals Connector (OSTI)

A 3-phase 22.9 kV/50 MVA 410 m HTS power cable system was installed at power grid of KEPCO and had been operated for 20 months. In the HTS cable system an open type cooling system was constructed for cooling LN2 using as coolant for superconducting cable. The cooling capacity of the cooling system was 6 kW at 69 K. Subcooled LN2 flew thorough 410 m HTS cable maintaining 69 K of operating temperature for HTS cable. The electric load had fluctuated continuously with the load status so that the cooling state was also controlled to keep stable operating condition. The consumed LN2 used for making subcooled state was refilled periodically and the amount was 3 tons in average. During all the operating period the HTS cable system supplied electric power stably without any problem.

2014-01-01T23:59:59.000Z

436

SEMIACTIVE DAMPING OF CABLES WITH SAG E.A. Johnson,1 R.E. Christenson,2 and B.F. Spencer, Jr.2  

E-Print Network (OSTI)

the previous work by adding sag, inclination, and axial flexibility to the cable model. The equa- tions damping, cable galloping, rain-wind induced vibration, cable sag, structural control INTRODUCTION Cables structures. These cables are subject to environmental excitations, such as rain-wind induced vibration

Johnson, Erik A.

437

E-Print Network 3.0 - aluminum-stabilized superconducting cables...  

NLE Websites -- All DOE Office Websites (Extended Search)

New superconducting technology will help America reduce the demand for additional electric power Summary: ,000-amp, 3-phase superconducting cable at American Electric Power's...

438

Complete Fiber/Copper Cable Solution for Long-Term Temperature...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

| US DOE Geothermal Program eere.energy.gov Talented technical team - Specialty fiber optics development, testing, and production - Downhole cable and tool development and...

439

Direct attach cable assembly specification analysis from 8 port S-parameters.  

E-Print Network (OSTI)

??This thesis focuses on test and characterization of the Direct Attach passive cables by 8 port s-parameter analysis. The setup comprises of the Network Analyzer,… (more)

Paithankar, Shachi

2011-01-01T23:59:59.000Z

440

Economic and environmental conditions for extraction and recycling of ground power cables.  

E-Print Network (OSTI)

?? In the thesis the costs for extracting ground power cables from grass, asphalt or cobblestone using excavator or Kabel-X is examined. This is then… (more)

Larsson, Henric

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Electromagnetic full wave modal analysis of frequency-dependent underground cables.  

E-Print Network (OSTI)

??In this thesis, a new method has been proposed for calculating the frequencydependent parameters of underground cables. The method uses full wave formulation for calculating… (more)

Habib, Md. Shahnoor

2011-01-01T23:59:59.000Z

442

Design and performance relationships for cable distribution in multi-story office buildings.  

E-Print Network (OSTI)

??Weaknesses associated with cable distribution systems suggest a lack of design consideration in the planning stage of a building. The primary question to be addressed… (more)

Ryan, Richard Cecil

2012-01-01T23:59:59.000Z

443

Automatic Voltage Control of Electrical Systems  

Science Journals Connector (OSTI)

... to have complete automatic voltage regulation and it also has supervisory control for its main substations. By a careful application of automatically controlled regulators it is shown that the voltage ...

1934-01-20T23:59:59.000Z

444

Implications of Pulser Voltage Ripple  

SciTech Connect

In a recent set of measurements obtained by G. Kamin, W. Manning, A. Molvik, and J. Sullivan, the voltage waveform of the diode pulser had a ripple of approximately {+-}1.3% of the 65 kV flattop voltage, and the beam current had a larger corresponding ripple of approximately {+-}8.4% of the 1.5 mA average current at the location of the second Faraday cup, approximately 1.9 m downstream from the ion source. The period of the ripple was about 1 {mu}s. It was initially unclear whether this large current ripple was in fact a true measurement of the current or a spurious measurement of noise produced by the pulser electronics. The purpose of this note is to provide simulations which closely match the experimental results and thereby corroborate the physical nature of those measurements, and to provide predictions of the amplitude of the current ripples as they propagate to the end of linear transport section. Additionally analytic estimates are obtained which lend some insight into the nature of the current fluctuations and to provide an estimate of what the maximum amplitude of the current fluctuations are expected to be, and conversely what initial ripple in the voltage source is allowed, given a smaller acceptable tolerance on the line charge density.

Barnard, J J

2011-12-21T23:59:59.000Z

445

Onset voltage of corona on coated conductors  

SciTech Connect

This paper is aimed for investigating the effect of surface coating on the positive and negative onset voltages of corona from stressed conductor as a pre-requisite for onset-voltage calculation. The electric field is accurately calculated by the charge simulation technique. The calculated onset voltages agreed satisfactorily with those measured experimentally for bare conductors. The effect of coating-layer thickness and permittivity as well as conductor radius and height on the onset-voltage values is discussed.

Abdel-Salam, M. [Assiut Univ. (Egypt). Electrical Engineering Dept.; Abo-Shal, Y. [SCECO-East, Dammam (Saudi Arabia). Electrical Engineering Div.

1995-12-31T23:59:59.000Z

446

Production process for advanced space satellite system cables/interconnects.  

SciTech Connect

This production process was generated for the satellite system program cables/interconnects group, which in essences had no well defined production process. The driver for the development of a formalized process was based on the set backs, problem areas, challenges, and need improvements faced from within the program at Sandia National Laboratories. In addition, the formal production process was developed from the Master's program of Engineering Management for New Mexico Institute of Mining and Technology in Socorro New Mexico and submitted as a thesis to meet the institute's graduating requirements.

Mendoza, Luis A.

2007-12-01T23:59:59.000Z

447

Loss of Cables, a Cyclin-Dependent Kinase Regulatory Protein, Is Associated with the Development of Endometrial Hyperplasia and Endometrial Cancer  

Science Journals Connector (OSTI)

...Articles Cell and Tumor Biology Loss of Cables, a Cyclin-Dependent Kinase Regulatory...in Western industrialized countries. Cables, a cyclin-dependent kinase binding...proliferation and/or differentiation. Cables mutant mice are viable, but develop endometrial...

Lawrence R. Zukerberg; Robert L. DeBernardo; Sandra D. Kirley; Massimo D’Apuzzo; Maureen P. Lynch; Ramey D. Littell; Linda R. Duska; Landin Boring; Bo R. Rueda

2004-01-01T23:59:59.000Z

448

Cables Enhances Cdk2 Tyrosine 15 Phosphorylation by Wee1, Inhibits Cell Growth, and Is Lost in Many Human Colon and Squamous Cancers  

Science Journals Connector (OSTI)

Regular Articles Tumor Biology Cables Enhances Cdk2 Tyrosine 15 Phosphorylation...phosphorylation and dephosphorylation events. Cables is a recently described novel cdk-interacting protein. In proliferating cells, Cables was predominantly localized in the nucleus...

Chin-Lee Wu; Sandra D. Kirley; Hua Xiao; Yenning Chuang; Daniel C. Chung; Lawrence R. Zukerberg

2001-10-01T23:59:59.000Z

449

Measurement of stability of cabled conductors cooled by He I at reduced temperature, or He II  

SciTech Connect

Stability tests of cabled NbTi alloy conductor are underway at the General Atomic High Field Test Facility, in support of the Team One effort of the DOE 12 Tesla Coil Development Program. A background field of up to 10 tesla within a 20 cm bore is provided by a nested pair of 4.2/sup 0/K bath cooled NbTi coils. An insulated bore insert tube (coldfinger) is provided in order to perform heat pulse/recovery tests of coiled samples in cooling regimes anticipated for the 1 m O.D. coil to be tested at the LLNL 12 tesla facility during FY 82. Specifically, tests are being performed in the 2.5 to 3/sup 0/K He I, and saturated superfluid (He II) regimes. The testing apparatus, procedures, and initial results are presented.

Hsu, Y.H.; Purcell, J.R.; Chen, W.Y.; Alcorn, J.S.

1980-09-01T23:59:59.000Z

450

20 IAEI NEWS July.August 2007 www.iaei.org CONTINUOUS CURRENTS THROUGH CURIOUS CABLES  

E-Print Network (OSTI)

module only a few inches away. Subsequent to the early days, where exposed terminals and insulating caps frames or mounting racks to provide some degree of mechanical protection from wind, rain, snow and ice cause the cable insulation to be abraded or place strain on the module terminal boxes where the cables

Johnson, Eric E.

451

An Internal Coaxial Cable Electrical Connector For Use In Downhole Tools  

DOE Patents (OSTI)

A seal for a coaxial cable electrical connector more specifically an internal seal for a coaxial cable connector placed within a coaxial cable and its constituent components. A coaxial cable connector is in electrical communcation with an inductive transformer and a coaxial cable. The connector is in electrical communication with the outer housing of the inductive transformer. A generally coaxial center conductor, a portion of which could be the coil in the inductive transformer, passes through the connector, is electrically insulated from the connector, and is in electrical communication with the conductive core of the coaxial cable. The electrically insulating material also doubles as a seal to safegaurd against penetration of fluid, thus protecting against shorting out of the electrical connection. The seal is a multi-component seal, which is pre-compressed to a desired pressure rating. The coaxial cable and inductive transformer are disposed within downhole tools to transmit electrical signals between downhole tools within a drill string. The internal coaxial cable connector and its attendant seal can be used in a plurality of downhole tools, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David S. (Lehi, UT); Dahlgren, Scott (Provo, UT); Fox, Joe (Spanish Fork, UT); Sneddon, Cameron (Provo, UT); Briscoe, Michael (Lehi, UT)

2005-09-20T23:59:59.000Z

452

Isogeometric rotation-free bending-stabilized cables: Statics, dynamics, bending strips and coupling with shells  

Science Journals Connector (OSTI)

Abstract An isogeometric cable formulation is derived from a 3D continuum, where large-deformation kinematics and the St. Venant–Kirchhoff constitutive law are assumed. It is also assumed that the cable cross-sections remain circular, planar, and orthogonal to the cable middle curve during the deformation. The cable geometry representation reduces to a curve in 3D space, and, because only displacement degrees of freedom are employed, only membrane and bending effects are accounted for in the modeling. Torsion is neglected and bending is confined to an osculating plane of the curve. In the case structural loading and response are confined to a plane, the formulation is reduced to a 2D Euler–Bernoulli beam of finite thickness. Bending terms also stabilize the cable formulation in the presence of compressive forces. The resulting cable formulation is validated in the regime of linear and nonlinear statics, and nonlinear dynamics. The concept of bending strips is extended to the case of multiple cables, and cable-shell coupling is also investigated. The formulation is presented in sufficient mathematical detail for straightforward computer implementation.

S.B. Raknes; X. Deng; Y. Bazilevs; D.J. Benson; K.M. Mathisen; T. Kvamsdal

2013-01-01T23:59:59.000Z

453

Valuable bridges : cable-stayed bridges and value engineering in American civil engineering culture, 1969-1979  

E-Print Network (OSTI)

A history and theory of cable-stayed bridges in the context of a cultural discourse on civil construction projects' value, this thesis studies the significance of cable-stayed bridge designs to 'value engineering' objectives ...

Samuels, Fallon M. (Fallon Michele)

2007-01-01T23:59:59.000Z

454

Extension and optimization of the load range of DRT test systems for testing extra-long HV and UHV cables  

Science Journals Connector (OSTI)

An increasing demand for testing long and extra-long HV and UHV cables such as submarine cables can be...2010), Mohaupt and Mehl (2011), Bergman and Bergman (2011). This testing technology has now been proven for...

P. Mohaupt; H. Geyer; B. A. Bergman…

2013-01-01T23:59:59.000Z

455

Surface and Structural Stabilities of Carbon Additives in High...  

NLE Websites -- All DOE Office Websites (Extended Search)

Structural Stabilities of Carbon Additives in High Voltage Lithium Ion Batteries. Surface and Structural Stabilities of Carbon Additives in High Voltage Lithium Ion Batteries....

456

Chapter 17. High-Voltage Systems and Dielectric Materials High-Voltage Systems and Dielectric Materials  

E-Print Network (OSTI)

aromatic, naphthenic, and paraffinic molecules with complex molecular structures. With the advancement

457

An energy harvesting system using the wind-induced vibration of a stay cable for powering  

Science Journals Connector (OSTI)

This paper proposes an electromagnetic energy harvesting system, which utilizes the wind-induced vibration of a stay cable, and investigates its feasibility for powering a wireless sensor node on the cable through numerical simulations as well as experimental tests. To this end, the ambient acceleration responses of a stay cable installed in an in-service cable-stayed bridge are measured, and then they are used as input excitations in cases of both numerical simulations and experimental tests to evaluate the performance of the proposed energy harvesting system. The results of the feasibility test demonstrate that the proposed system generates sufficient electricity for operation of a wireless sensor node attached on the cable under the moderate wind conditions.

Hyung-Jo Jung; In-Ho Kim; Seon-Jun Jang

2011-01-01T23:59:59.000Z

458

The University of Texas at Austin September 30, 2011 Cable Trays for Communications Systems 27 05 36-1  

E-Print Network (OSTI)

Cable Tray Installation Guidelines 4. NFPA 70B, Recommended Practice for Electrical Equipment manufacturer that the cable tray system has been UL-tested to be continuously grounded. c) Where the desiredThe University of Texas at Austin September 30, 2011 Cable Trays for Communications Systems 27 05

Dawson, Clint N.

459

Cable Pili and the 22-Kilodalton Adhesin Are Required for Burkholderia cenocepacia Binding to and Transmigration across the Squamous Epithelium  

Science Journals Connector (OSTI)

...PATHOGEN-HOST CELL MOLECULAR INTERACTIONS Cable Pili and the 22-Kilodalton Adhesin Are...Burkholderia cenocepacia strains expressing both cable (Cbl) pili and the 22-kDa adhesin bind...binding (0 to 8%). Mutants lacking either cable pili or the adhesin were compromised in...

Teresa A. Urban; Joanna B. Goldberg; Janet F. Forstner; Umadevi S. Sajjan

2005-09-01T23:59:59.000Z

460

Abstract--Many surgical robots use cable-conduit pairs in a pull-pull configuration to actuate the instruments  

E-Print Network (OSTI)

Abstract-- Many surgical robots use cable-conduit pairs in a pull-pull configuration to actuate the instruments and transmit power into the patient's body. Friction between the cable and the conduit makes the system nonlinear and accounts for major losses in tension transmission across the cable. This paper

Yao, Bin

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Local Voltage Support from Distributed Energy Resources to Prevent Air Conditioner Motor Stalling  

SciTech Connect

Microgrid voltage collapse often happens when there is a high percentage of low inertia air-conditioning (AC) motors in the power systems. The stalling of the AC motors results in Fault Induced Delayed Voltage Recovery (FIDVR). A hybrid load model including typical building loads, AC motor loads, and other induction motor loads is built to simulate the motoring stalling phenomena. Furthermore, distributed energy resources (DE) with local voltage support capability are utilized to boost the local bus voltage during a fault, and prevent the motor stalling. The simulation results are presented. The analysis of the simulation results show that local voltage support from multiple DEs can effectively and economically solve the microgrid voltage collapse problem.

Baone, Chaitanya A [ORNL] [ORNL; Xu, Yan [ORNL] [ORNL; Kueck, John D [ORNL] [ORNL

2010-01-01T23:59:59.000Z

462

High Temperature, High Voltage Fully Integrated Gate Driver Circuit  

Energy.gov (U.S. Department of Energy (DOE))

2010 DOE Vehicle Technologies and Hydrogen Programs Annual Merit Review and Peer Evaluation Meeting, June 7-11, 2010 -- Washington D.C.

463

High Temperature, High Voltage Fully Integrated Gate Driver Circuit  

Energy.gov (U.S. Department of Energy (DOE))

2009 DOE Hydrogen Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting, May 18-22, 2009 -- Washington D.C.

464

Integrating a Feature Selection Algorithm for Classification of Voltage Sags Originated in Transmission and Distribution Networks  

Science Journals Connector (OSTI)

As a global problem in the power quality area, voltage sags are matter of high interest for both utilities and customers. With a view to resolving the problem of sag source location in the power network, this paper introduces a new method based on dimension ... Keywords: Direction, Hybrid Method, Mpca, Voltage Sag

Abbas Khosravi; Toni Martinez; Joaquim Melendez; Joan Colomer; Jorge Sanchez

2007-06-01T23:59:59.000Z

465

A Static Pattern-Independent Technique for Power Grid Voltage Integrity Verification  

E-Print Network (OSTI)

A Static Pattern-Independent Technique for Power Grid Voltage Integrity Verification Dionysios Design verification must include the power grid. Checking that the voltage on the power grid does) the obviously large size of the power grids for modern high-performance chips, and ii) the difficulty of setting

Najm, Farid N.

466

A Static PatternIndependent Technique for Power Grid Voltage Integrity Verification #  

E-Print Network (OSTI)

A Static PatternĀ­Independent Technique for Power Grid Voltage Integrity Verification # Dionysios Design verification must include the power grid. Checking that the voltage on the power grid does) the obviously large size of the power grids for modern highĀ­performance chips, and ii) the di#culty of setting

Najm, Farid N.

467

LM193/LM293/LM393/LM2903 Low Power Low Offset Voltage Dual Comparators  

E-Print Network (OSTI)

LM193/LM293/LM393/LM2903 Low Power Low Offset Voltage Dual Comparators General Description The LM clock timers; multivibrators and high voltage digital logic gates. The LM193 series was designed to directly interface with TTL and CMOS. When operated from both plus and minus power supplies, the LM193

Lanterman, Aaron

468

Reactive power management of distribution networks with wind generation for improving voltage stability  

E-Print Network (OSTI)

Reactive power management of distribution networks with wind generation for improving voltage February 2013 Available online Keywords: Composite load Distributed generation D-STATCOM Q with distributed wind generation. Firstly, the impact of high wind penetration on the static voltage stability

Pota, Himanshu Roy

469

VOLTAGE COLLAPSE AND TRANSIENT ENERGY FUNCTION ANALYSES OF AC/DC SYSTEMS  

E-Print Network (OSTI)

for power system dynamic models, including a third order representation of high voltage direct current (HVDC power limits, HVDC firing angle limits and voltage dependent current order limits (VDCOL) are shown the derivation of individual component Lyapunov functions for simplified models of HVDC links connected

CaƱizares, Claudio A.

470

CABLE AOORIs*. HICRONIZER. MOORLblOWN. NEW ,SRIEY  

Office of Legacy Management (LM)

NEW ALBANY ROAD . MOORESTOWN . NEW ]ERSEY NEW ALBANY ROAD . MOORESTOWN . NEW ]ERSEY CABLE AOORIs*. HICRONIZER. MOORLblOWN. NEW ,SRIEY be returned further obliga- may desire any patent protection, provi#ed; however, that the costa in connectSo& with the pregaration;~~fillrig nnd prosecution of the same shall be entirely: at ?SG,~~e~enS.e ,of our..company. This provision, how- ever, ls.' subJect:to eny.~prlor'arra~cmont between your Institu- tion and the government with respect to inventions and p?j,tents. ,.: 3,ri 'I :: .:v:ri :!:!p, +lo.~nl.~~! ( '.'I! &f :, > ,>,' :'It'r*i&: sltibr~!the understandfng that your Instttution will ca,rry such insurance as you'may deem ndvi~able~ln aonoec- tion with this m ill or its use ~lhile :kt the UnivsF@#b v' "t -' . ' - IN,TERNATI.ONAL PULVERIZING c0RP0RAi.1~

471

Studies on electrical cable insulation for nuclear applications  

SciTech Connect

Two new polyethylene cable insulations have been formulated for nuclear applications, and have been tested under gamma radiation. Both insulations are based on low density polyethylene, one with PbO and the other with Sb{sub 2}O{sub 3} as additives. The test results show that the concept of using inorganic anti-oxidants to retard radiation initiated oxidation is viable, and PbO is more effective than Sb{sub 2}O{sub 3} in slowing down radiation initiated oxidation (RIO). Also, radiation degradation data for polyethylene and polyvinyl chloride at 60{degrees}C have been generated, which will be used to understand radiation initiated oxidation process on these materials combined with the 25{degrees}C data that will be generated in the future. 14 refs., 41 figs., 3 tabs.

Lee, B.S.; Soo, P.; MacKenzie, D.R. [Brookhaven National Lab., Upton, NY (USA); Blackburn, P. [Beloit Junior-Senior High School, KS (USA)

1989-12-01T23:59:59.000Z

472

Compact multiwavelength transmitter module for multimode fiber optic ribbon cable  

DOE Patents (OSTI)

A compact multiwavelength transmitter module for multimode fiber optic ribbon cable, which couples light from an M.times.N array of emitters onto N fibers, where the M wavelength may be distributed across two or more vertical-cavity surface-emitting laser (VCSEL) chips, and combining emitters and multiplexer into a compact package that is compatible with placement on a printed circuit board. A key feature is bringing together two emitter arrays fabricated on different substrates--each array designed for a different wavelength--into close physical proximity. Another key feature is to compactly and efficiently combine the light from two or more clusters of optical emitters, each in a different wavelength band, into a fiber ribbon.

Deri, Robert J. (Pleasanton, CA); Pocha, Michael D. (Livermore, CA); Larson, Michael C. (Goleta, CA); Garrett, Henry E. (Livermore, CA)

2002-01-01T23:59:59.000Z

473

Light weight underground pipe or cable installing device  

SciTech Connect

This invention pertains to a light weight underground pipe or cable installing device adapted for use in a narrow and deep operating trench. More particularly this underground pipe installing device employs a pair of laterally movable gates positioned adjacent the bottom of the operating trench where the earth is more solid to securely clamp the device in the operating trench to enable it to withstand the forces exerted as the actuating rod is forced through the earth from the so-called operating trench to the target trench. To accommodate the laterally movable gates positioned adjacent the bottom of the narrow pipe installing device, a pair of top operated double-acting rod clamping jaws, operated by a hydraulic cylinder positioned above the actuating rod are employed.

Schosek, W. O.

1985-01-08T23:59:59.000Z

474

Definition: Operating Voltage | Open Energy Information  

Open Energy Info (EERE)

Voltage Voltage Jump to: navigation, search Dictionary.png Operating Voltage The voltage level by which an electrical system is designated and to which certain operating characteristics of the system are related; also, the effective (root-mean-square) potential difference between any two conductors or between a conductor and the ground. The actual voltage of the circuit may vary somewhat above or below this value.[1] Related Terms system References ā†‘ Glossary of Terms Used in Reliability Standards An LikeLike UnlikeLike You like this.Sign Up to see what your friends like. inline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Operating_Voltage&oldid=480559" Categories: Definitions ISGAN Definitions What links here Related changes

475

Wind Power Plant Voltage Stability Evaluation: Preprint  

SciTech Connect

Voltage stability refers to the ability of a power system to maintain steady voltages at all buses in the system after being subjected to a disturbance from a given initial operating condition. Voltage stability depends on a power system's ability to maintain and/or restore equilibrium between load demand and supply. Instability that may result occurs in the form of a progressive fall or rise of voltages of some buses. Possible outcomes of voltage instability are the loss of load in an area or tripped transmission lines and other elements by their protective systems, which may lead to cascading outages. The loss of synchronism of some generators may result from these outages or from operating conditions that violate a synchronous generator's field current limit, or in the case of variable speed wind turbine generator, the current limits of power switches. This paper investigates the impact of wind power plants on power system voltage stability by using synchrophasor measurements.

Muljadi, E.; Zhang, Y. C.

2014-09-01T23:59:59.000Z

476

Group 3: Humidity, Temperature, and Voltage (Presentation)  

SciTech Connect

Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

Wohlgemuth, J.

2013-05-01T23:59:59.000Z

477

Nexans & Pirelli Awarded Major Energy Sector Contract  

E-Print Network (OSTI)

km (56 miles) of new high-voltage cables. The contract calls for the manufacture and laying of three. Pirelli will manufacture and install two submarine power cables and one telecommunications cable. These cables will be manufactured at Pirelli's Arco Felice (Naples), Italy plant. The Pirelli share

Kavehrad, Mohsen

478

Fiber optic sensors for monitoring sodium circuits and power grid cables  

SciTech Connect

At Kalpakkam, India, a programme on development of Raman Distributed Temperature sensor (RDTS) for Fast Breeder Reactors (FBR) application is undertaken. Leak detection in sodium circuits of FBR is critical for the safety and performance of the reactors. It is demonstrated that RDTS can be usefully employed in monitoring sodium circuits and in tracking the percolating sodium in case of any leak. Aluminum Conductor Steel Reinforced (ACSR) cable is commonly used as overhead power transmission cable in power grid. A second application demonstrates the suitability of using RDTS to monitor this transmission cable for any defect. (authors)

Kasinathan, M.; Sosamma, S.; Pandian, C.; Vijayakumar, V.; Chandramouli, S.; Nashine, B. K.; Rao, C. B.; Murali, N.; Rajan, K. K.; Jayakumar, T. [IGCAR, Kalpakkam (India)

2011-07-01T23:59:59.000Z

479

A Cabled Acoustic Telemetry System for Detecting and Tracking Juvenile Salmon: Part 2. Three-Dimensional Tracking and Passage Outcomes  

SciTech Connect

In Part 1 of this paper [1], we presented the engineering design and instrumentation of the Juvenile Salmon Acoustic Telemetry System (JSATS) cabled system, a nonproprietary technology developed by the U.S. Army Corps of Engineers, Portland District, to meet the needs for monitoring the survival of juvenile salmonids through the 31 dams in the Federal Columbia River Power System. Here in Part 2, we describe how the JSATS cabled system was employed as a reference sensor network for detecting and tracking juvenile salmon. Time-of-arrival data for valid detections on four hydrophones were used to solve for the three-dimensional (3D) position of fish surgically implanted with JSATS acoustic transmitters. Validation tests demonstrated high accuracy of 3D tracking up to 100 m from the John Day Dam spillway. The along-dam component, used for assigning the route of fish passage, had the highest accuracy; the median errors ranged from 0.06 to 0.22 m, and root mean square errors ranged from 0.05 to 0.56 m at distances up to 100 m. For the case study at John Day Dam during 2008, the range for 3D tracking was more than 100 m upstream of the dam face where hydrophones were deployed, and detection and tracking probabilities of fish tagged with JSATS acoustic transmitters were higher than 98%. JSATS cabled systems have been successfully deployed on several major dams to acquire information for salmon protection and for development of more “fish-friendly” hydroelectric facilities.

Deng, Zhiqun; Weiland, Mark A.; Fu, Tao; Seim, Thomas A.; Lamarche, Brian L.; Choi, Eric Y.; Carlson, Thomas J.; Eppard, Matthew B.

2011-05-26T23:59:59.000Z

480

SEMIACTIVE DAMPING OF CABLES WITH SAG E.A. Johnson,1 R.E. Christenson,2 and B.F. Spencer, Jr.2  

E-Print Network (OSTI)

- cantly superior supplemental damping. This paper extends the previous work by adding sag, inclination damping, cable galloping, rain-wind induced vibration, cable-stayed bridges, structural control bridges and other cable structures. These cables are subject to environmental excitations, such as rain-wind

Johnson, Erik A.

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

DESIGN AND IMPLEMENTATION OF A FUZZY LOGIC-BASED VOLTAGE CONTROLLER FOR VOLTAGE REGULATION  

E-Print Network (OSTI)

1 DESIGN AND IMPLEMENTATION OF A FUZZY LOGIC-BASED VOLTAGE CONTROLLER FOR VOLTAGE REGULATION In this paper the design and implementation of a fuzzy logic-based controller is described for regulating the output voltage of a synchronous generator. An automated fuzzy logic-based control strategy is presented

LaMeres, Brock J.

482

Voltage regulation in linear induction accelerators  

DOE Patents (OSTI)

Improvement in voltage regulation in a Linear Induction Accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance.

Parsons, William M. (Santa Fe, NM)

1992-01-01T23:59:59.000Z

483

Voltage regulation in linear induction accelerators  

DOE Patents (OSTI)

Improvement in voltage regulation in a linear induction accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core is disclosed. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance. 4 figs.

Parsons, W.M.

1992-12-29T23:59:59.000Z

484

NREL: Measurements and Characterization - Current Versus Voltage  

NLE Websites -- All DOE Office Websites (Extended Search)

Current Versus Voltage Current Versus Voltage The National Renewable Energy Laboratory (NREL) Device Performance group uses current versus voltage (I-V) measurement systems to assess the main performance parameters for photovoltaic (PV) cells and modules. I-V measurement systems determine the output performance of devices, including: open-circuit voltage (Voc), short-circuit current (Isc), fill factor (FF), maximum power output of the device (Pmax), voltage at maximum power (Vmax), current at maximum power (Imax), and conversion efficiency of the device (Ī·). Some I-V systems may also be used to perform dark I-V measurements to determine diode properties and series and shunt resistances. We use three I-V systems to measure performance of individual PV cells; and four for modules - two for measurements under simulated conditions; and

485

Non-contact current and voltage sensor  

DOE Patents (OSTI)

A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

Carpenter, Gary D; El-Essawy, Wael; Ferreira, Alexandre Peixoto; Keller, Thomas Walter; Rubio, Juan C; Schappert, Michael A

2014-03-25T23:59:59.000Z

486

A Functional Interaction of the C-Abl and Heat Shock Response Pathways in  

NLE Websites -- All DOE Office Websites (Extended Search)

Functional Interaction of the C-Abl and Heat Shock Response Pathways in Functional Interaction of the C-Abl and Heat Shock Response Pathways in Radio-Adaptive Response Hang Su & Zhi-Min Yuan University of Texas Health Science Center at San Antonio Abstract A functional interaction of the c-Abl and heat shock response pathways in radio-adaptive response Hang Su & Zhi-Min Yuan. Department of Radiation Oncology, UTHSCSA The radio-adaptive response, i.e. a low dose of radiation can protect cells and organisms from the effects of a subsequent higher dose, is a phenomenon that has been widely recognized. However, mechanisms underlying such radiation hormesis remain largely unclear. Our preliminary studies have uncovered a crucial role for the c-Abl tyrosine kinase as evidenced by that c-Abl-deficient cells exhibited a compromised

487

CFD Numerical Simulation of Vortex-Induced Vibration of a Stay Cable under a Wind Profile  

Science Journals Connector (OSTI)

VIV (Vortex-induced vibration) of a stay cable subjected to a wind profile is numerically simulated through combining CFD ... numerical model. Under a profile of mean wind speed, unsteady aerodynamic lift coeffic...

Wenli Chen; Hui Li

2009-01-01T23:59:59.000Z

488

Manufacturability and assembly aspects of an advanced cable gland design for an electrical motor drive  

Science Journals Connector (OSTI)

At present, typical motor junction boxes do not incorporate cable glands, which would provide good electrical performance in terms of electromagnetic compatibility and ease of use, especially regarding the grounding connection. In this paper, a manufacturability and assembly analysis for the new construction of a rigid body feeder cable junction of an electric motor is presented especially for converter drives. Design for manufacturing and assembly aspects are presented in detail. One of the novelty values of the paper is to estimate the manufacturability with respect to the product's performance. Further, assembling and mounting the cable gland should be made easy, and the need of various tools and installing stages should be eliminated. The new connector design makes mounting easy and installation stages are minimised. The electrical performance of the cable gland is also measured and verified in a real environment for glands constructed with steel and zinc coated steel.

Juha-P. Strom; Pertti Silventoinen; Harri Eskelinen

2009-01-01T23:59:59.000Z

489

Federal Power Act section 202(c)- Cross-Sound Cable Company, August 2002  

Energy.gov (U.S. Department of Energy (DOE))

On August 16, 2002, due to concerns regarding the availability of electricity on Long Island in the State of New York, a 202(c) order was issued directing Cross-Sound Cable Company to operate the...

490

Dielectrometry measurements of moisture diffusion and temperature dynamics in oil impregnated paper insulated electric power cables  

E-Print Network (OSTI)

Paper insulated lead covered (PILC) cables have played an important role in underground power distribution for a hundred years. Replacing aged PILC before failure is critical to managing power distribution. Three prominent ...

Thomas, Zachary M. (Zachary Michael)

2007-01-01T23:59:59.000Z

491

Study on 10 kVDC powered junction box for a cabled ocean observatory system  

Science Journals Connector (OSTI)

A cabled ocean observatory system that can provide abundant power and broad bandwidth communication for undersea instruments ... current (kVDC) with up to 10 kW power, along with 1 Gigabit/sec Ethernet communicat...

Yan-hu Chen ???; Can-jun Yang ???; De-jun Li ???; Bo Jin ? ?…

2013-04-01T23:59:59.000Z

492

A new generation of heat-resistant power submersible cables. Part 2  

Science Journals Connector (OSTI)

In this research paper, we continue a review of electro-physical and other characteristics of F-50 and F-4MB fluoropolymers and their correspondence to the criteria of efficiency of insulation submersible cabl...

Ya. Z. Mesenzhnik

2012-04-01T23:59:59.000Z

493

Method for Estimating Loss over Wide Wavelength Region of Fiber Cables Installed in Access Networks  

Science Journals Connector (OSTI)

We propose a simple method for estimating the loss of installed cables to expand WDM access networks. Loss at arbitrary wavelengths can be very accurately predicted from the measured...

Tsujikawa, Kyozo; Takaya, Masaaki; Tomita, Shigeru

494