High voltage VLF testing of power cables  

SciTech Connect

This publication describes a laboratory test program conducted with the objective to develop a test that would replace the existing dc withstand test. The article describes the methodology used to establish the voltage duration and magnitude of VLF (0.1 Hz) high voltage field tests suitable for crosslinked polyethylene (XLPE) insulated power cable. The results show that the voltage breakdown of laboratory aged XLPE cable at 0.1 Hz is approximately equal to that at 60 Hz, that proof tests at 0.1 Hz is approximately equal to that at 60 Hz, that proof tests at 0.1 Hz cause very little damage to the cable, and that 0.1 Hz testing appears to be a satisfactory alternate to dc testing. Preliminary values are suggested for voltage magnitude and time duration of cable acceptance, maintenance and proof tests at 0.1 Hz for XLPE cable rated up to 35 kV. A program is underway to similarly evaluate samples of service-aged XLPE cable; as well as to demonstrate the use of the preliminary test values at typical utility installations.

Eager, G.S.; Katz, C.; Fryszczyn, B. [Cable Technology Labs., Inc., New Brunswick, NJ (United States); Densley, J. [Ontario Hydro, Toronto, Ontario (Canada); Bernstein, B.S. [EPRI, Washington, DC (United States)

1997-04-01T23:59:59.000Z

2

Fiber Optic Cables in High Voltage Environments  

Science Conference Proceedings (OSTI)

In recent years, it has become common for electric utilities to place fiber optic cables within their transmission rights-of-way. Overhead transmission power line corridors can provide the telecommunications industry with cost-effective alternative routes, and at the same time benefit the electric utilities by generating additional revenues using existing facilities. Also, within the power utility industry, reliable internal communications are vital to ensure ptotection and control of the power system. S...

2000-12-07T23:59:59.000Z

3

Curing system for high voltage cross linked cables  

DOE Patents (OSTI)

This invention makes extruded, vulcanized, high voltage cables insulated with thermosetting compounds at much higher rates of production and with superior insulation of reduced thickness and with reduced cavities or voids in the insulation. As the cable comes from an extruder, it passes into a curing chamber with a heat booster that quickly raises the insulation to a temperature at which it is cured much more quickly than with steam heating of the prior art. A high temperature liquid in contact with the insulation maintains the high temperature; and because of the greater curing heat, the cable can travel through the curing chamber at a faster rate and into a cooling tube where it contacts with a cooling liquid under high pressure. The insulation compound is treated to reduce the size of cavities; and the high pressure maintained by the curing and cooling mediums prevent expansion of cavities before the insulation is set.

Bahder, George (Edison, NJ); Katz, Carlos (Edison, NJ); Bopp, Louis A. (Fair Haven, NJ)

1978-01-01T23:59:59.000Z

4

Qualification High Voltage Testing of Short Triax HTS Cables in the Laboratory  

Science Conference Proceedings (OSTI)

In order to qualify the electrical insulation design of future HTS cables installed in the electric grid, a number of high voltage qualification tests are generally performed in the laboratory on either single-phase model cables and/or actual three-phase cable samples. Prior to installation of the 200-m Triax HTS cable at the American Electric Power Bixby substation near Columbus, Ohio, in September, 2006, such tests were conducted on both single-phase model cables made at ORNL and tri-axial cable sections cut off from cable made on a production run. The three-phase tri-axial design provides some specific testing challenges since the ground shield and three phases are concentric about a central former with each phase separated by dielectric tape insulation immersed in liquid nitrogen. The samples were successfully tested and qualified for partial discharge inception, AC withstand, and lightning impulse where voltage is applied to one phase with the other phases grounded. In addition one of the phase pairs was tested for dc withstand as a ldquoworst caserdquo scenario to simulate the effect of VLF (Very Low Frequency) tests on the actual cable installed at the Bixby site. The model and prototype cables will be described and the high voltage test results summarized.

James, David Randy [ORNL; Sauers, Isidor [ORNL; Ellis, Alvin R [ORNL; Tuncer, Enis [ORNL; Gouge, Michael J [ORNL; Demko, Jonathan A [ORNL; Duckworth, Robert C [ORNL; Rey, Christopher M [ORNL

2009-01-01T23:59:59.000Z

5

High Voltage Testing of a 5-meter Prototype Triaxial HTS Cable  

SciTech Connect

High voltage tests were performed on a 5-m long prototype triaxial HTS cable (supplied by Ultera) at ORNL in preparation for installation of a 200-m HTS cable of the same design at the AEP utility substation in Columbus, Ohio. The triaxial design comprises three concentric phases and shield around a common former with the phase to phase dielectric at cryogenic temperature. Advantages of this design include increased current density, a reduced amount of HTS tape needed, and reduced heat load. The phase to phase voltage will be 13.2 kVrms (7.6 kVrms to ground). Preliminary testing was done on half-scale and full-scale terminations which successfully passed AC withstand, partial discharge, and impulse tests. High voltage tests conducted on the 5-m cable with the cable straight and after bending 90 degrees were ac withstand to 39 kVrms, partial discharge inception, and a minimum of 10 positive and 10 negative lightning waveform impulses at 110 kV. Phase to phase insulation was tested by applying high voltage to each phase one at a time with all the other phases grounded. Partial discharge data will be presented. The 5-m prototype triaxial HTS cable passed all the HV tests performed, with a PD inception voltage significantly above the required voltage.

Sauers, Isidor [ORNL; James, David Randy [ORNL; Ellis, Alvin R [ORNL; Tuncer, Enis [ORNL; Pace, Marshall O [ORNL; Gouge, Michael J [ORNL; Demko, Jonathan A [ORNL; Lindsay, David T [ORNL

2007-01-01T23:59:59.000Z

6

Real time prelocalisation of electrical defaults on high voltage underground cable (single-phase case)  

Science Conference Proceedings (OSTI)

This paper proposes an assistance tool to the prelocalisation of the insulation defaults affecting electrical single-phase cables by using voltage and current measurements available in source substation. An equivalent network modeling defaults to the ... Keywords: default distance, distributed parameters, insulation default, prelocalisation, sheath, underground cable

Thameur Aloui; Fathi Ben Amar; Nizar Derbel; Hsan Hadj Abdallah

2010-05-01T23:59:59.000Z

7

Cable Aging Management Training Course for Low-Voltage Cables  

Science Conference Proceedings (OSTI)

The "EPRI PSE Cable Aging Training Course for Low-Voltage Cables" provides a basis for understanding of the aging of the insulation and jackets of electrical cables used in low-voltage systems. Practical techniques for determining which cables are prone to premature aging and for evaluating their condition are described. The course contains 11 modules. The first 9 modules describe the body of the cable aging management process. The last two modules, "Cable Failure Assessment" and "Performing a Walkdown o...

2003-11-24T23:59:59.000Z

8

Ceramic end seal design for high temperature high voltage nuclear instrumentation cables  

DOE Patents (OSTI)

A coaxial, hermetically sealed end structure is described for electrical instrumentation cables. A generally tubular ceramic body is hermetically sealed within a tubular sheath which is in turn sealed to the cable sheath. One end of the elongated tubular ceramic insulator is sealed to a metal end cap. The other end of the elongated tubular insulator has an end surface which is shaped concave relative to a central conductor which extends out of this end surface. When the end seal is hermetically sealed to an instrumentation cable device and the central conductor is maintained at a high positive potential relative to the tubular metal sheath, the electric field between the central conductor and the outer sheath tends to collect electrons from the concave end surface of the insulator. This minimizes breakdown pulse noise generation when instrumentation potentials are applied to the central conductor.

Meiss, James D. (Berkeley, CA); Cannon, Collins P. (Kennewick, VA)

1979-01-01T23:59:59.000Z

9

Low-Voltage Cable Aging Management Guidance  

Science Conference Proceedings (OSTI)

This report, intended for use by power plant engineers and craft and administrative personnel who are responsible for cable system aging management, provides guidance on the effective and efficient application of current information and techniques related to aging and condition monitoring (CM) of low-voltage cables. The identification of cables that are prone to early aging and the timely replacement or repair of cables that are degraded will minimize unnecessary power losses, unplanned shutdowns, ...

2013-12-23T23:59:59.000Z

10

Commercialization of Medium Voltage HTS Triax TM Cable Systems  

SciTech Connect

The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax{TM} cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed the market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax{TM} cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS TriaxTM design, so it provided an economical tool for these of the project tasks.

Knoll, David

2012-12-31T23:59:59.000Z

11

Demonstration of Commissioning Tests for Extra-High Voltage Cross-Linked Polyethylene Cable Systems at Los Angeles Department of Wat er and Power  

Science Conference Proceedings (OSTI)

Today, utilities are installing an increasing number of cross-linked polyethylene (XLPE) transmission cables with system voltages ranging from 115 kV up to 345 kV. This report summarizes field partial discharge measurements and high-voltage ac commissioning tests performed on a Los Angeles Department of Water and Power (LADWP) 230-kV XLPE transmission cable system. The commissioning tests were performed with a field transportable, variable frequency, series resonant test set at 1.4 times rated voltage.

2002-09-11T23:59:59.000Z

12

Development of extruded and molded straight joint for ultra high-voltage XLPE cable  

Science Conference Proceedings (OSTI)

In Japan, 154-kV crosslinked polyethylene-insulated cables (XLPE) are already in use for long-distance tranmission lines, but 275-kV XLPE cables are used only for short-distance lines (without joints) on the premises of power-generation plants and substations. 275-kV XLPE cable is expected to be used for long-distance transmission lines in the near future because of its overall cost advantage. To respond to this need, a straight-through joint with the same reliability as the cable should be developed. Reliable joints should be formed and molded with the same curable PE compounds as the cable insulation. At present, 154-kV XLPE cables for long-distance transmission lines are usually constructed with the joint comprising XLPE insulation wrapped with curable PE tape and molded by heating. However, this taped molded joint has the disadvantages of troublesome tape handling. On the other hand, extruded molded joints are constructed by injecting curable melted PE into a mold with an extruder, eliminating contamination. The report describes the characteristics of the extruded and molded joint developed for 154, 275 and 500 kV class XLPE cables.

Shimomura, T.; Ando, K.; Asahi, K.; Sugiyama, K.

1986-01-01T23:59:59.000Z

13

EPRI Dissolved Gas Analysis Guide for High-Voltage Cables and Transformers  

Science Conference Proceedings (OSTI)

Dissolved gas analysis (DGA) is deemed to be the most economical and reliable diagnostic test for both cables and transformers, and it is finding widespread application worldwide. The general subject of DGA has continued to receive considerable attention for several decades. While there is commonality between cable and transformer DGA and the oil-paper insulating system, there are marked differences with respect to DGA due to the differing designs, materials, and operating conditions associated with ...

2012-12-20T23:59:59.000Z

14

EPRI Dissolved Gas Analysis Guide for High Voltage Cables and Transformers – 2013 Update  

Science Conference Proceedings (OSTI)

Dissolved gas analysis (DGA) is deemed to be an economical and reliable diagnostic test for both cables and transformers and is finding widespread application worldwide. The general subject of DGA has continued to receive considerable attention for several decades. While there is commonality between cable and transformer DGA and the oil-paper insulating system, there are marked differences with respect to DGA due to the differing designs, materials, and operating conditions associated with the two ...

2013-12-20T23:59:59.000Z

15

Medium Voltage Cable Aging Management Guide, Revision 1  

Science Conference Proceedings (OSTI)

Medium-voltage cables (5- to 35-kV rated cables) have provided reasonable service in nuclear power plants. However, there is a concern that cables that have experienced long periods of wet service might degrade and fail in service. Because most plants have had few problems with medium-voltage cable, little on-staff experience with medium-voltage cables exists at most sites. This report has been prepared to provide information that will be of practical use when questions concerning medium-voltage cable lo...

2010-11-29T23:59:59.000Z

16

High conductance surge cable  

DOE Patents (OSTI)

An electrical cable for connecting transient voltage surge suppressors to electrical power panels. A strip of electrically conductive foil defines a longitudinal axis, with a length of an electrical conductor electrically attached to the metallic foil along the longitudinal axis. The strip of electrically conductive foil and the length of an electrical conductor are covered by an insulating material. For impedance matching purposes, triangular sections can be removed from the ends of the electrically conductive foil at the time of installation. 6 figs.

Murray, M.M.; Wilfong, D.H.; Lomax, R.E.

1998-12-08T23:59:59.000Z

17

Nano-Composite Dielectrics on Medium-Voltage Model Cables  

Science Conference Proceedings (OSTI)

EPRI early recognized the potential for nanotechnology in power distribution and started a program in 2003 to explore the possibilities of using the technology to enhance the properties of high-voltage (HV) cable dielectrics based on both polyethylene and on ethylene-propylene rubber. This research resulted in encouraging findings, particularly for a formulation based on functionalized silicon dioxide nanoparticles in a cross-linked polyethylene (XLPE) polymer. Following this success, EPRI entered into a...

2007-12-19T23:59:59.000Z

18

Shield Losses in Medium-Voltage Cables  

Science Conference Proceedings (OSTI)

Utilities can substantially reduce cable costs and circulating current losses by optimizing the design of concentric neutral conductors for underground distribution cables and by configuring installed cables to minimize energy loss. This guide shows how to design neutral conductors for maximum cost-effectiveness and includes calculations of circulating current losses and ampacities for commonly used cables.

1987-12-14T23:59:59.000Z

19

On-line partial discharge monitoring system and data processing using WTST-NST filter for high voltage power cable  

Science Conference Proceedings (OSTI)

Defects inside insulation of HV XLPE cable accessories can lead to partial discharge (PD) activity. When PD activity happens, leakage current may flow through the grounded line. To acquire the PD current signal, one practicable and effective method is ... Keywords: MRD-MRR algorithm, adaptive WTST-NST filter, condition based maintenance(CBM), on-line monitoring, partial discharge, power cable, stationary noise interference

Hui Wang; Chengjun Huang; Li Zhang; Yong Qian; Junhua Liu; Linpeng Yao; Canxin Guo; Xiuchen Jiang

2009-07-01T23:59:59.000Z

20

High Temperature Superconducting Underground Cable  

SciTech Connect

The purpose of this Project was to design, build, install and demonstrate the technical feasibility of an underground high temperature superconducting (HTS) power cable installed between two utility substations. In the first phase two HTS cables, 320 m and 30 m in length, were constructed using 1st generation BSCCO wire. The two 34.5 kV, 800 Arms, 48 MVA sections were connected together using a superconducting joint in an underground vault. In the second phase the 30 m BSCCO cable was replaced by one constructed with 2nd generation YBCO wire. 2nd generation wire is needed for commercialization because of inherent cost and performance benefits. Primary objectives of the Project were to build and operate an HTS cable system which demonstrates significant progress towards commercial progress and addresses real world utility concerns such as installation, maintenance, reliability and compatibility with the existing grid. Four key technical areas addressed were the HTS cable and terminations (where the cable connects to the grid), cryogenic refrigeration system, underground cable-to-cable joint (needed for replacement of cable sections) and cost-effective 2nd generation HTS wire. This was the world’s first installation and operation of an HTS cable underground, between two utility substations as well as the first to demonstrate a cable-to-cable joint, remote monitoring system and 2nd generation HTS.

Farrell, Roger, A.

2010-02-28T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Evaluation of Medium-Voltage Cable Joints  

Science Conference Proceedings (OSTI)

This research is a continuation of work evaluating performance of state-of-the-art joints. Three single-phase cold shrink joints and three "I"-type premolded separable connector joints were evaluated. Two of the separable connectors were rated 600 A and one was rated 900 A; both were installed on ethylene propylene rubber (EPR) 15-kV cables.

2006-09-27T23:59:59.000Z

22

Long-Term Operations: Ethylene Propylene Rubber (EPR) Insulation Accelerated Aging Methodology Research for Medium-Voltage Cables  

Science Conference Proceedings (OSTI)

Ethylene propylene rubber–insulated (EPR-insulated) cables are the most common type of medium-voltage cables in U.S. plants. Accelerating the aging of EPR insulations has proven difficult. The research described in this report attempted alternative ways to accelerate the aging of EPR insulation in hopes of achieving a better method. Stresses—such as lower temperature, high-conductivity water, and additional voltage—were used to accelerate aging in a generic EPR cable. Additionally, ...

2012-09-20T23:59:59.000Z

23

High-Temperature Superconductivity Cable Demonstration Projects...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High-Temperature Superconductivity Cable Demonstration Projects High-Temperature Superconductivity Cable Demonstration Projects A National Effort to Introduce New Technology into...

24

Plant Support Engineering: Aging Management Program Guidance for Medium- Voltage Cable Systems for Nuclear Power Plants  

Science Conference Proceedings (OSTI)

Regulatory and management concern regarding the reliability of medium-voltage cable systems at nuclear plants has been increasing for 5–10 years. The staff of the U.S. Nuclear Regulatory Commission (NRC) are concerned that wetted (up to and including submergence) medium-voltage cable circuits may be degrading to the point at which multiple cable circuits may fail when called on to perform functions affecting safety. Utility managers are concerned that cables may fail, causing adverse safety consequences ...

2010-06-02T23:59:59.000Z

25

Compact High-Temperature Superconducting Cable Wins ' ...  

Science Conference Proceedings (OSTI)

Compact High-Temperature Superconducting Cable Wins 'R&D 100' Award. From NIST Tech Beat: June 22, 2011. ...

2011-07-06T23:59:59.000Z

26

On-Line Dissolved Gas Analysis in High-Pressure Fluid-Filled Cables  

Science Conference Proceedings (OSTI)

Highly reliable underground transmission lines are essential to deliver power consistently. Reliability may be affected as underground laminar dielectric cable circuits age and their condition degenerates. High-pressure fluid-filled (HPFF) pipe-type cable systems have been the preferred high-voltage transmission cable type in North America from the earliest transmission cable installations in the 1930s through the late 1990s and still account for the largest percentage (80%) of installed length. Although...

2009-11-17T23:59:59.000Z

27

High current pulse transmission cable  

DOE Patents (OSTI)

This invention is comprised of a transmission cable for carrying high current pulses in which an even numbered plurality of electrical conductors surrounds a central ground conductor. Each electrical conductor is connected so that it at any instant in time it will carry current of opposite polarity to the polarity carried by adjacent conductors. This arrangement cancels practically all of the external fields generated by current in the conductors.

Parsons, W.M.

1990-09-28T23:59:59.000Z

28

Monitoring Volume Transport through Measurement of Cable Voltage across the Korea Strait  

Science Conference Proceedings (OSTI)

Voltage induced by the Tsushima Current on an abandoned submarine telephone cable between Pusan, Korea, and Hamada, Japan, has been measured since March 1998 in order to monitor the volume transport through the Korea Strait. Voltage has a good ...

Kuh Kim; Sang Jin Lyu; Young-Gyu Kim; Byung Ho Choi; Keisuke Taira; Henry T. Perkins; William J. Teague; Jeffrey W. Book

2004-04-01T23:59:59.000Z

29

HIGH VOLTAGE GENERATOR  

DOE Patents (OSTI)

This patent relates to high voltage supply circuits adapted for providing operating voltages for GeigerMueller counter tubes, and is especially directed to an arrangement for maintaining uniform voltage under changing conditions of operation. In the usual power supply arrangement for counter tubes the counter voltage is taken from across the power supply output capacitor. If the count rate exceeds the current delivering capaciiy of the capacitor, the capacitor voltage will drop, decreasing the counter voltage. The present invention provides a multivibrator which has its output voltage controlled by a signal proportional to the counting rate. As the counting rate increases beyond the current delivering capacity of the capacitor, the rectified voltage output from the multivibrator is increased to maintain uniform counter voltage.

Zito, G.V.

1959-04-21T23:59:59.000Z

30

Plant Support Engineering: Failure Mechanism Assessment of Medium-Voltage Ethylene Propylene Rubber Cables - Revision 1  

Science Conference Proceedings (OSTI)

This report presents the results of research that assessed failed ethylene propylene rubber (EPR) medium-voltage (MV) cables to determine the failure mechanism. This information will be used to identify appropriate electrical tests that can be performed on in-service cable. Assessed were two 34-year-old cables manufactured by Okonite with black EPR insulation and a 25-year-old Anaconda UniShield cable with pink EPR. All three had failed and had experienced long-term wetting during service. This report is...

2009-05-28T23:59:59.000Z

31

A Superconducting transformer system for high current cable testing  

E-Print Network (OSTI)

A Superconducting Transformer System for High Current CableDC) superconducting transformer system for the high currentsuperconducting cables. The transformer consists of a core-

Godeke, A.

2010-01-01T23:59:59.000Z

32

A Superconducting transformer system for high current cable testing  

Science Conference Proceedings (OSTI)

This article describes the development of a direct-current (dc) superconducting transformer system for the high current test of superconducting cables. The transformer consists of a core-free 10 464 turn primary solenoid which is enclosed by a 6.5 turn secondary. The transformer is designed to deliver a 50 kA dc secondary current at a dc primary current of about 50 A. The secondary current is measured inductively using two toroidal-wound Rogowski coils. The Rogowski coil signal is digitally integrated, resulting in a voltage signal that is proportional to the secondary current. This voltage signal is used to control the secondary current using a feedback loop which automatically compensates for resistive losses in the splices to the superconducting cable samples that are connected to the secondary. The system has been commissioned up to 28 kA secondary current. The reproducibility in the secondary current measurement is better than 0.05% for the relevant current range up to 25 kA. The drift in the secondary current, which results from drift in the digital integrator, is estimated to be below 0.5 A/min. The system's performance is further demonstrated through a voltage-current measurement on a superconducting cable sample at 11 T background magnetic field. The superconducting transformer system enables fast, high resolution, economic, and safe tests of the critical current of superconducting cable samples.

Godeke, A.; Dietderich, D. R.; Joseph, J. M.; Lizarazo, J.; Prestemon, S. O.; Miller, G.; Weijers, H. W.

2010-02-15T23:59:59.000Z

33

Plant Engineering, Aging Management Program Guidance for Medium-Voltage Cable Systems for Nuclear Power Plants, Revision 1  

Science Conference Proceedings (OSTI)

This report was prepared in response to regulatory and management concern regarding the reliability of medium-voltage cable systems at nuclear plants. The staff of the U.S. Nuclear Regulatory Commission (NRC) have been concerned that wetted (up to and including submergence) medium-voltage cable circuits may be degrading to the point at which multiple cable circuits may fail when called on to perform functions affecting safety. A utility manager’s concern is that cables may fail, causing ...

2013-06-03T23:59:59.000Z

34

Low-Voltage Environmentally-Qualified Cable License Renewal Industry Report -- Revision 1  

Science Conference Proceedings (OSTI)

Low-voltage environmentally-qualified cable components have been evaluated relative to the effects of age-related degradation mechanisms; the capability of current design limits, inservice examination, testing, repair, refurbishment, and other programs to manage these effects; and the assurance that these cable components can continue to perform their intended safety functions in the license renewal term. This industry report (IR), one of a series of ten, provides a generic technical basis for evaluation...

1994-07-01T23:59:59.000Z

35

Plant Engineering: Medium-Voltage Cable Failure Mechanism Research, Update 5  

Science Conference Proceedings (OSTI)

This report compiles and extends previously published information gained from EPRI research involving medium-voltage cable failure mechanisms. Four previous reports in this series (EPRI reports 1018777, 1021069, 1022965, and 1024894) presented various results from the study of cables removed from underground applications after 29–38 years of service. The sum knowledge from that work is contained in those four documents, but to view the cumulative information and lessons learned would require ...

2013-09-30T23:59:59.000Z

36

Plant Support Engineering: Failure Mechanism Assessment of Medium Voltage Ethylene Propylene Rubber Cables  

Science Conference Proceedings (OSTI)

This report presents the results of research that assessed failed ethylene propylene rubber (EPR) medium-voltage (MV) cables to determine the failure mechanism. This information will be used to identify appropriate electrical tests that can be performed on in-service cable. Assessed were a 34-year-old cable manufactured by Okonite with black EPR insulation and a 20-year-old Anaconda Uni-Shieldcable with pink EPR. Both had failed, and both had experienced long-term wetting during service.

2007-08-20T23:59:59.000Z

37

High voltage pulse conditioning  

DOE Patents (OSTI)

Apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close.

Stringfield, R.M.; Wheat, R.M. Jr.

1989-02-21T23:59:59.000Z

38

High voltage pulse conditioning  

DOE Patents (OSTI)

Apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close.

Springfield, Ray M. (Sante Fe, NM); Wheat, Jr., Robert M. (Los Alamos, NM)

1990-01-01T23:59:59.000Z

39

HIGH VOLTAGE GENERATOR  

DOE Patents (OSTI)

A generator for producing relatively large currents at high voltages is described. In general, the invention comprises a plurality of capacitors connected in series by a plurality of switches alternately disposed with the capacitors. The above-noted circuit is mounted for movement with respect to contact members and switch closure means so that a load device and power supply are connected across successive numbers of capacitors, while the other capacitors are successively charged with the same power supply.

Schwemin, A.J.

1959-03-17T23:59:59.000Z

40

HIGH VOLTAGE GENERATOR  

DOE Patents (OSTI)

A generator is presented for producing relatively large currents at high voltages. In general, the invention comprises a plurality of capacitors connected in series by a plurality of switches alternately disposed with the capacitors. The circuit is mounted for movement with respect to contact members and switch closure means so that a load device and power supply are connected across successive numbers of capacitors, while the other capacitors are successively charged with the same power supply.

Schwemin, A.J.

1959-03-17T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

HIGH VOLTAGE ION SOURCE  

DOE Patents (OSTI)

A device is described for providing a source of molecular ions having a large output current and with an accelerated energy of the order of 600 kv. Ions are produced in an ion source which is provided with a water-cooled source grid of metal to effect maximum recombination of atomic ions to molecular ions. A very high accelerating voltage is applied to withdraw and accelerate the molecular ions from the source, and means are provided for dumping the excess electrons at the lowest possible potentials. An accelerating grid is placed adjacent to the source grid and a slotted, grounded accelerating electrode is placed adjacent to the accelerating grid. A potential of about 35 kv is maintained between the source grid and accelerating grid, and a potential of about 600 kv is maintained between the accelerating grid and accelerating electrode. In order to keep at a minimum the large number of oscillating electrons which are created when such high voltages are employed in the vicinity of a strong magnetic field, a plurality of high voltage cascaded shields are employed with a conventional electron dumping system being employed between each shield so as to dump the electrons at the lowest possible potential rather than at 600 kv.

Luce, J.S.

1960-04-19T23:59:59.000Z

42

High voltage DC power supply  

DOE Patents (OSTI)

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively. 7 figs.

Droege, T.F.

1989-12-19T23:59:59.000Z

43

High voltage variable diameter insulator  

DOE Patents (OSTI)

A high voltage feedthrough assembly (10) having a tubular insulator (15) extending between the ground plane ring (16) and the high voltage ring (30). The insulator (15) is made of Pyrex and decreases in diameter from the ground plane ring (16) to the high voltage ring (30), producing equipotential lines almost perpendicular to the wall (27) of the insulator (15) to optimize the voltage-holding capability of the feedthrough assembly (10).

Vanecek, David L. (Martinez, CA); Pike, Chester D. (Pinole, CA)

1984-01-01T23:59:59.000Z

44

Molds for cable dielectrics  

DOE Patents (OSTI)

Molds for use in making end moldings for high-voltage cables are described wherein the dielectric insulator of a cable is heated and molded to conform to a desired shape. As a consequence, high quality substantially bubble-free cable connectors suitable for mating to premanufactured fittings are made.

Roose, Lars D. (Albuquerque, NM)

1996-01-01T23:59:59.000Z

45

High voltage feedthrough bushing  

DOE Patents (OSTI)

A feedthrough bushing for a high voltage diode provides for using compression sealing for all sealing surfaces. A diode assembly includes a central conductor extending through the bushing and a grading ring assembly circumferentially surrounding and coaxial with the central conductor. A flexible conductive plate extends between and compressively seals against the central conductor and the grading ring assembly, wherein the flexibility of the plate allows inner and outer portions of the plate to axially translate for compression sealing against the central conductor and the grading ring assembly, respectively. The inner portion of the plate is bolted to the central conductor for affecting sealing. A compression beam is also bolted to the central conductor and engages the outer portion of the plate to urge the outer portion toward the grading ring assembly to obtain compression sealing therebetween.

Brucker, J.P.

1991-12-31T23:59:59.000Z

46

An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.  

SciTech Connect

References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

Litzenberger, Wayne; Lava, Val

1994-08-01T23:59:59.000Z

47

High frequency breakdown voltage  

SciTech Connect

This report contains information about the effect of frequency on the breakdown voltage of an air gap at standard pressure and temperature, 76 mm Hg and O{degrees}C, respectively. The frequencies of interest are 47 MHz and 60 MHz. Additionally, the breakdown in vacuum is briefly considered. The breakdown mechanism is explained on the basis of collision and ionization. The presence of the positive ions produced by ionization enhances the field in the gap, and thus determines the breakdown. When a low-frequency voltage is applied across the gap, the breakdown mechanism is the same as that caused by the DC or static voltage. However, when the frequency exceeds the first critical value f{sub c}, the positive ions are trapped in the gap, increasing the field considerably. This makes the breakdown occur earlier; in other words, the breakdown voltage is lowered. As the frequency increases two decades or more, the second critical frequency, f{sub ce}, is reached. This time the electrons start being trapped in the gap. Those electrons that travel multiple times across the gap before reaching the positive electrode result in an enormous number of electrons and positive ions being present in the gap. The result is a further decrease of the breakdown voltage. However, increasing the frequency does not decrease the breakdown voltage correspondingly. In fact, the associated breakdown field intensity is almost constant (about 29 kV/cm).The reason is that the recombination rate increases and counterbalances the production rate, thus reducing the effect of the positive ions` concentration in the gap. The theory of collision and ionization does not apply to the breakdown in vacuum. It seems that the breakdown in vacuum is primarily determined by the irregularities on the surfaces of the electrodes. Therefore, the effect of frequency on the breakdown, if any, is of secondary importance.

Chu, Thanh Duy

1992-03-01T23:59:59.000Z

48

End moldings for cable dielectrics  

DOE Patents (OSTI)

End moldings for high-voltage cables are described wherein the dielectric insulator of the cable is heated and molded to conform to a desired shape. As a consequence, high quality substantially bubble- free cable connectors suitable for mating to premanufactured fittings are made. Disclosed are a method for making the cable connectors either in the field or in a factory, molds suitable for use with the method, and the molded cable connectors, themselves.

Roose, L.D.

1993-12-31T23:59:59.000Z

49

End moldings for cable dielectrics  

DOE Patents (OSTI)

End moldings for high-voltage cables are described wherein the dielectric insulator of the cable is heated and molded to conform to a desired shape. As a consequence, high quality substantially bubble-free cable connectors suitable for mating to premanufactured fittings are made. Disclosed is a method for making the cable connectors either in the field or in a factory, molds suitable for use with the method, and the molded cable connectors, themselves.

Roose, Lars D. (Albuquerque, NM)

2000-01-01T23:59:59.000Z

50

High Stress Cable Using Nanocomposites: Status Report and Future Prospects  

Science Conference Proceedings (OSTI)

The Electric Power Research Institute (EPRI) has been pursuing the development of a nanocomposite cable insulation compound for several years. Early successes in the laboratory led to commercialization efforts with Dow Chemical Company and several trial runs of commercial-scale compound manufacturing. Medium-voltage underground cables were made with the experimental compound. The fundamental challenge in dispersing nanoscale particles into a bulk polymer is achieving a homogenous dispersion throughout th...

2011-12-18T23:59:59.000Z

51

Plant Support Engineering: Aging Management Program Development Guidance for AC and DC Low-Voltage Power Cable Systems for Nuclear P ower Plants  

Science Conference Proceedings (OSTI)

Regulatory and management concern regarding the reliability of low-voltage power cable systems at nuclear plants has been increasing for the past 5–10 years. The staff of the United States Nuclear Regulatory Commission are concerned that wetted (up to and including submergence) low-voltage power cable circuits may be degrading to the point at which multiple cable circuits may fail when called on to perform functions affecting safety. Utility managers are concerned that cables may fail, causing adverse sa...

2010-06-02T23:59:59.000Z

52

Compact High-Temperature Superconducting Cables ...  

Science Conference Proceedings (OSTI)

... Beside power transmission, the flexible cabling concept could be used ... and for medical applications such as next-generation magnetic resonance ...

2011-02-25T23:59:59.000Z

53

Process of modifying a cable end  

DOE Patents (OSTI)

End moldings for high-voltage cables are described wherein the dielectric insulator of the cable is heated and molded to conform to a desired shape. As a consequence, high quality substantially bubble-free cable connectors suitable for mating to premanufactured fittings are made. Disclosed are a method for making the cable connectors either in the field or in a factory, molds suitable for use with the method, and the molded cable connectors, themselves. 5 figs.

Roose, L.D.

1995-08-01T23:59:59.000Z

54

Process of modifying a cable end  

DOE Patents (OSTI)

End moldings for high-voltage cables are described wherein the dielectric insulator of the cable is heated and molded to conform to a desired shape. As a consequence, high quality substantially bubble-free cable connectors suitable for mating to premanufactured fittings are made. Disclosed are a method for making the cable connectors either in the field or in a factory, molds suitable for use with the method, and the molded cable connectors, themselves.

Roose, Lars D. (Albuquerque, NM)

1995-01-01T23:59:59.000Z

55

High-voltage-compatible, fully depleted CCDs  

E-Print Network (OSTI)

result of this high-voltage requirement, we have taken a di?voltage is necessary in order to meet the PSF requirementsrequirements for SNAP have resulted in a need to operate at substrate bias voltages

2006-01-01T23:59:59.000Z

56

High voltage photovoltaic power converter  

DOE Patents (OSTI)

An array of independently connected photovoltaic cells on a semi-insulating substrate contains reflective coatings between the cells to enhance efficiency. A uniform, flat top laser beam profile is illuminated upon the array to produce electrical current having high voltage. An essentially wireless system includes a laser energy source being fed through optic fiber and cast upon the photovoltaic cell array to prevent stray electrical signals prior to use of the current from the array. Direct bandgap, single crystal semiconductor materials, such as GaAs, are commonly used in the array. Useful applications of the system include locations where high voltages are provided to confined spaces such as in explosive detonation, accelerators, photo cathodes and medical appliances.

Haigh, Ronald E. (Arvada, CO); Wojtczuk, Steve (Cambridge, MA); Jacobson, Gerard F. (Livermore, CA); Hagans, Karla G. (Livermore, CA)

2001-01-01T23:59:59.000Z

57

TRANSISTOR HIGH VOLTAGE POWER SUPPLY  

DOE Patents (OSTI)

High voltage, direct current power supplies are described for use with battery powered nuclear detection equipment. The particular advantages of the power supply described, are increased efficiency and reduced size and welght brought about by the use of transistors in the circuit. An important feature resides tn the employment of a pair of transistors in an alternatefiring oscillator circuit having a coupling transformer and other circuit components which are used for interconnecting the various electrodes of the transistors.

Driver, G.E.

1958-07-15T23:59:59.000Z

58

Comparative High Voltage Impulse Measurement  

Science Conference Proceedings (OSTI)

... substrate and surrounded by insulating oil; the low ... the amplitudes of the voltage peaks that are ... The uncertainties in the peak output voltages for the ...

2013-04-19T23:59:59.000Z

59

High voltage RF feedthrough bushing  

DOE Patents (OSTI)

Described is a multi-element, high voltage radio frequency bushing for trmitting RF energy to an antenna located in a vacuum container. The bushing includes a center conductor of complex geometrical shape, an outer coaxial shield conductor, and a thin-walled hollow truncated cone insulator disposed between central and outer conductors. The shape of the center conductor, which includes a reverse curvature portion formed of a radially inwardly directed shoulder and a convex portion, controls the uniformity of the axial surface gradient on the insulator cone. The outer shield has a first substantially cylindrical portion and a second radially inwardly extending truncated cone portion.

Grotz, Glenn F. (Huntington Station, NY)

1984-01-01T23:59:59.000Z

60

Plant Support Engineering: Life Cycle Management Planning Sourcebooks: Medium-Voltage (MV) Cables and Accessories (Terminations and Splices)  

Science Conference Proceedings (OSTI)

EPRI is producing a series of Life Cycle Management Planning Sourcebooks, each containing a compilation of industry experience information and data on aging degradation and historical performance for a specific type of system, structure, or component (SSC). This sourcebook provides information and guidance for implementing cost-effective life cycle management (LCM) planning for medium-voltage (MV) cables and accessories (terminations and field splices)

2006-11-20T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Low power, scalable multichannel high voltage controller  

DOE Patents (OSTI)

A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

Stamps, James Frederick (Livermore, CA); Crocker, Robert Ward (Fremont, CA); Yee, Daniel Dadwa (Dublin, CA); Dils, David Wright (Fort Worth, TX)

2006-03-14T23:59:59.000Z

62

Low power, scalable multichannel high voltage controller  

DOE Patents (OSTI)

A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

Stamps, James Frederick (Livermore, CA); Crocker, Robert Ward (Fremont, CA); Yee, Daniel Dadwa (Dublin, CA); Dils, David Wright (Fort Worth, TX)

2008-03-25T23:59:59.000Z

63

High-Temperature Superconductivity Cable Demonstration Projects  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Temperature Temperature Superconductivity Cable Demonstration Projects Superconductivity Power Equipment www.oe.energy.gov Phone: 202-586-1411 Office of Electricity Delivery and Energy Reliability, OE-1 U.S. Department of Energy - 1000 Independence Avenue, SW - Washington, DC 20585. Plugging America Into the Future of Power "A National Effort to Introduce New Technology into the Power Delivery Infrastructure" "In order to meet President Obama's ambitious energy goals, we must modernize the nation's electrical grid to improve the transmission, storage and reliability of clean energy across the country and help to move renewable energy from the places it can be produced to the places it can be used. The Department of Energy is working with industry partners to develop the

64

HIGH VOLTAGE, HIGH CURRENT SPARK GAP SWITCH  

DOE Patents (OSTI)

A high voltage and current spark gap switch comprising two main electrodes insulatingly supported in opposed spaced relationship and a middle electrode supported medially between the main electrodes and symmetrically about the median line of the main electrodes is described. The middle electrode has a perforation aligned with the median line and an irradiation electrode insulatingly supported in the body of the middle electrode normal to the median line and protruding into the perforation. (AEC)

Dike, R.S.; Lier, D.W.; Schofield, A.E.; Tuck, J.L.

1962-04-17T23:59:59.000Z

65

Characterisation of the VELO High Voltage System  

E-Print Network (OSTI)

The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; verification of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence that the high voltage system can be safely used and demonstrate that low noise is produced by the power supplies. LHCb Public Note, LHCb-2008-009Contents 1

Barinjaka Rakotomiaramanana; Chris Parkes; Lars Eklund

2008-01-01T23:59:59.000Z

66

Characterisation of the VELO High Voltage System  

E-Print Network (OSTI)

The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; vercation of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence th...

Rakotomiaramanana, B; Eklund, L

2008-01-01T23:59:59.000Z

67

Characterisation of the VELO High Voltage System  

E-Print Network (OSTI)

The high voltage system supplies the bias voltage to the 88 silicon sensors which comprise the LHCb Vertex Locator (VELO). This note describes the results of the tests which have been performed on the hardware of the high voltage system of the VELO. Each individual test detailed in this note corresponds to a specific requirement of the system. These requirements arise primarily from ensuring the safety of the silicon sensors and the quality of the data taken from the VELO modules. The tests performed are in four categories: normal operation of the high voltage system; verification of its stability under operation; discussion of its behaviour in failure modes; and details of operation at low voltage. Noteworthy issues, identified through the tests, include the behaviour of the high voltage modules at voltages below 9V, the current limit that can be applied during ramping of the voltage, and the speed with which the voltage is cut during failures of the system. The results of these tests provide high confidence...

Rakotomiaramanana, B; Eklund, L

2008-01-01T23:59:59.000Z

68

High Voltage Safety Act | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High Voltage Safety Act High Voltage Safety Act High Voltage Safety Act < Back Eligibility Commercial Construction Developer General Public/Consumer Industrial Installer/Contractor Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Georgia Program Type Safety and Operational Guidelines Siting and Permitting The purpose of the High Voltage Safety Act is to prevent injury to persons and property and interruptions of utility service resulting from accidental or inadvertent contact with high-voltage electric lines by providing that no work shall be done in the vicinity of such lines unless and until the owner or operator thereof has been notified of such work and has taken the appropriate safety measures. The Georgia Public Service Commission requires

69

High-voltage-compatible, fully depleted CCDs  

SciTech Connect

We describe charge-coupled device (CCD) developmentactivities at the Lawrence Berkeley National Laboratory (LBNL).Back-illuminated CCDs fabricated on 200-300 mu m thick, fully depleted,high-resistivity silicon substrates are produced in partnership with acommercial CCD foundry.The CCDs are fully depleted by the application ofa substrate bias voltage. Spatial resolution considerations requireoperation of thick, fully depleted CCDs at high substrate bias voltages.We have developed CCDs that are compatible with substrate bias voltagesof at least 200V. This improves spatial resolution for a given thickness,and allows for full depletion of thicker CCDs than previously considered.We have demonstrated full depletion of 650-675 mu m thick CCDs, withpotential applications in direct x-ray detection. In this work we discussthe issues related to high-voltage operation of fully depleted CCDs, aswell as experimental results on high-voltage-compatible CCDs.

Holland, Stephen E.; Bebek, Chris J.; Dawson, Kyle S.; Emes, JohnE.; Fabricius, Max H.; Fairfield, Jessaym A.; Groom, Don E.; Karcher, A.; Kolbe, William F.; Palaio, Nick P.; Roe, Natalie A.; Wang, Guobin

2006-05-15T23:59:59.000Z

70

Fully synthetic taped insulation cables  

DOE Patents (OSTI)

The present invention is a cable which, although constructed from inexpensive polyolefin tapes and using typical impregnating oils, furnishes high voltage capability up to 765 kV, and has such excellent dielectric characteristics and heat transfer properties that it is capable of operation at capacities equal to or higher than presently available cables at a given voltage. This is accomplished by using polyethylene, polybutene or polypropylene insulating tape which has been specially processed to attain properties which are not generally found in these materials, but are required for their use in impregnated electrical cables. Chief among these properties is compatibility with impregnating oil.

Forsyth, E.B.; Muller, A.C.

1983-07-15T23:59:59.000Z

71

Environmental and Potential Health Effects of High Voltage Direct Current Transmission Lines  

Science Conference Proceedings (OSTI)

High-voltage direct current (HVDC) technology plays an important but highly selective role in the U.S. power delivery system. It is a cost-effective technology for transferring bulk power over long distances, a critical technology for asynchronous grid interconnection, and the preferred technology for long-distance underwater cable transmission. Current interest in renovating the national grid for greater loads and higher reliability as well as unique applications for renewable energy projects, including...

2012-07-31T23:59:59.000Z

72

Contaminated Outdoor High Voltage Insulators  

Science Conference Proceedings (OSTI)

The external insulation of power lines and outdoor substations is a weak point in transmission systems. The insulation is particularly susceptible to failure if proper attention has not been given to its design, condition monitoring, and maintenance. In regions with high contamination levels, regular maintenance and the application of palliative measures can be critical to ensure that the system meets its outage performance targets. This can involve pure maintenance measures such as cleaning the insulato...

2009-12-22T23:59:59.000Z

73

Nuclear instrumentation cable end seal  

DOE Patents (OSTI)

An improved coaxial end seal for hermetically sealed nuclear instrumentation cable exhibiting an improved breakdown pulse noise characteristic under high voltage, high temperature conditions. A tubular insulator body has metallized interior and exterior surface portions which are braze sealed to a center conductor and an outer conductive sheath. The end surface of the insulator body which is directed toward the coaxial cable to which it is sealed has a recessed surface portion within which the braze seal material terminates.

Cannon, Collins P. (Richland, WA); Brown, Donald P. (Richland, WA)

1979-01-01T23:59:59.000Z

74

Modular high voltage power supply for chemical analysis  

DOE Patents (OSTI)

A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2008-07-15T23:59:59.000Z

75

Modular high voltage power supply for chemical analysis  

DOE Patents (OSTI)

A high voltage power supply for use in a system such as a microfluidics system, uses a DC--DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC--DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2007-01-09T23:59:59.000Z

76

Nuclear Energy Plant Optimization (NEPO) final report on aging and condition monitoring of low-voltage cable materials.  

SciTech Connect

This report summarizes results generated on a 5-year cable-aging program that constituted part of the Nuclear Energy Plant Optimization (NEPO) program, an effort cosponsored by the U. S. Department of Energy (DOE) and the Electric Power Research Institute (EPRI). The NEPO cable-aging effort concentrated on two important issues involving the development of better lifetime prediction methods as well as the development and testing of novel cable condition-monitoring (CM) techniques. To address improved life prediction methods, we first describe the use of time-temperature superposition principles, indicating how this approach improves the testing of the Arrhenius model by utilizing all of the experimentally generated data instead of a few selected and processed data points. Although reasonable superposition is often found, we show several cases where non-superposition is evident, a situation that violates the constant acceleration assumption normally used in accelerated aging studies. Long-term aging results over extended temperature ranges allow us to show that curvature in Arrhenius plots for elongation is a common occurrence. In all cases the curvature results in a lowering of the Arrhenius activation energy at lower temperatures implying that typical extrapolation of high temperature results over-estimates material lifetimes. The long-term results also allow us to test the significance of extrapolating through the crystalline melting point of semi-crystalline materials. By utilizing ultrasensitive oxygen consumption (UOC) measurements, we show that it is possible to probe the low temperature extrapolation region normally inaccessible to conventional accelerated aging studies. This allows the quantitative testing of the often-used Arrhenius extrapolation assumption. Such testing indicates that many materials again show evidence of ''downward'' curvature (E{sub a} values drop as the aging temperature is lowered) consistent with the limited elongation results and many literature results. It is also shown how the UOC approach allows the probing of temperatures that cross through the crystalline melting point region of semi-crystalline materials such as XLPO and EPR cable insulations. New results on combined environment aging of neoprene and hypalon cable jacketing materials are presented and offer additional evidence in support of our time-temperature-dose rate (t-T-DR) superposition approach that had been used successfully in the past for such situations.

Assink, Roger Alan; Gillen, Kenneth Todd; Bernstein, Robert

2005-11-01T23:59:59.000Z

77

A Value Proposition for Developing an Industry Database for High Voltage Circuit Breakers & CIM Data Objects for T&D  

Science Conference Proceedings (OSTI)

EPRI initiated work to develop databases for performance analysis and benchmarking in order to address issues of performance data availability, support industry efforts to maximize power delivery asset values, and optimize maintenance activities. With the successful development of an industrywide database for distribution cables and the extension of that work to power transformers, interest has turned to high-voltage circuit breakers (HVCBs).

2007-11-19T23:59:59.000Z

78

Fully synthetic taped insulation cables  

DOE Patents (OSTI)

A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

Forsyth, Eric B. (Brookhaven, NY); Muller, Albert C. (Center Moriches, NY)

1984-01-01T23:59:59.000Z

79

Aging Cable Assessment Guideline  

Science Conference Proceedings (OSTI)

Medium- and low-voltage cables have provided reasonable service in power plants. However, there is a concern that cables that have experienced long periods of stressed service and especially wet service might degrade and fail in service. Because most plants have had few problems with cables, little on-staff experience with cables exists at most sites. This report provides information that will be of practical use when assessing cable longevity in adverse environments and service conditions that may ...

2013-12-17T23:59:59.000Z

80

Initial Acceptance Criteria Concepts and Data for Assessing Longevity of Low-Voltage Cable Insulations and Jackets  

Science Conference Proceedings (OSTI)

The cables installed in nuclear plants have long lives in most applications. However, the service conditions for some applications can cause the jackets and insulations of cables to age more rapidly than normal. It is desirable to have acceptance criteria for continued service of those cables experiencing significant aging. This report establishes a basis for acceptance criteria, provides a method for estimating remaining cable life, and provides aging profiles under various thermal and radiation conditi...

2005-03-28T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Functionalized High Voltage Spinel Composite for High Power ...  

Science Conference Proceedings (OSTI)

Recently, spinel LiNi0.5Mn1.5O4 with high working voltage and long cycle life makes it become the one of most promising cathode for high power delivery.

82

Aging Power Cable Maintenance Guideline  

Science Conference Proceedings (OSTI)

Medium-voltage cables (5- to 35-kV rated cables) have provided reasonable service in power plants. However, there is a concern that cables that have experienced long periods of wet service might degrade and fail in service. Because most plants have had few problems with medium-voltage cables, little on-staff experience with medium-voltage cables exists at most sites. This report provides information that will be of practical use when questions concerning medium-voltage cable longevity in adverse ...

2012-11-16T23:59:59.000Z

83

Motor voltage high harmonics influence to efficient energy usage  

Science Conference Proceedings (OSTI)

Analysis of the effect of non-sinusoidal voltages on the three-phase induction motor is presented in the paper. When the induction motors are supplied by a rectangular shape of the voltage inverter with high levels of harmonic voltage (Uh,i ... Keywords: energy efficiency, harmonics, induction motor, non-sinusoidal voltage, power losses

Miloje M. Kostic; Branka B. Kostic

2011-07-01T23:59:59.000Z

84

Superconducting Cable Termination  

SciTech Connect

Disclosed is a termination that connects high temperature superconducting (HTS) cable immersed in pressurized liquid nitrogen to high voltage and neutral (shield) external bushings at ambient temperature and pressure. The termination consists of a splice between the HTS power (inner) and shield (outer) conductors and concentric copper pipes which are the conductors in the termination. There is also a transition from the dielectric tape insulator used in the HTS cable to the insulators used between and around the copper pipe conductors in the termination. At the warm end of the termination the copper pipes are connected via copper braided straps to the conventional warm external bushings which have low thermal stresses. This termination allows for a natural temperature gradient in the copper pipe conductors inside the termination which enables the controlled flashing of the pressurized liquid coolant (nitrogen) to the gaseous state. Thus the entire termination is near the coolant supply pressure and the high voltage and shield cold bushings, a highly stressed component used in most HTS cables, are eliminated. A sliding seal allows for cable contraction as it is cooled from room temperature to ˜72-82 K. Seals, static vacuum, and multi-layer superinsulation minimize radial heat leak to the environment.

Sinha, Uday K. (Carrollton, GA); Tolbert, Jerry (Newnan, GA)

2005-08-30T23:59:59.000Z

85

The US market for high-temperature superconducting wire in transmission cable applications  

SciTech Connect

Telephone interviews were conducted with 23 utility engineers concerning the future prospects for high-temperature superconducting (HTS) transmission cables. All have direct responsibility for transmission in their utility, most of them in a management capacity. The engineers represented their utilities as members of the Electric Power Research Institute`s Underground Transmission Task Force (which has since been disbanded). In that capacity, they followed the superconducting transmission cable program and are aware of the cryogenic implications. Nineteen of the 23 engineers stated the market for underground transmission would grow during the next decade. Twelve of those specified an annual growth rate; the average of these responses was 5.6%. Adjusting that figure downward to incorporate the remaining responses, this study assumes an average growth rate of 3.4%. Factors driving the growth rate include the difficulty in securing rights-of-way for overhead lines, new construction techniques that reduce the costs of underground transmission, deregulation, and the possibility that public utility commissions will allow utilities to include overhead costs in their rate base. Utilities have few plans to replace existing cable as preventive maintenance, even though much of the existing cable has exceeded its 40-year lifetime. Ten of the respondents said the availability of a superconducting cable with the same life-cycle costs as a conventional cable and twice the ampacity would induce them to consider retrofits. The respondents said a cable with those characteristics would capture 73% of their cable retrofits.

Forbes, D.

1996-04-01T23:59:59.000Z

86

Activated Sintering, Spark Plasma Sintering and High Voltage ...  

Science Conference Proceedings (OSTI)

Mar 4, 2013 ... Novel Synthesis and Consolidation of Powder Materials : Activated Sintering, Spark Plasma Sintering and High Voltage Electric Discharge ...

87

Utilizing cable winding and industrial robots to facilitate the manufacturing of electric machines  

Science Conference Proceedings (OSTI)

Cable wound electric machines are used mainly for high voltage and direct-drive applications. They can be found in areas such as wind power, hydropower, wave power and high-voltage motors. Compared to conventional winding techniques, cable winding includes ... Keywords: Automated production, Electric machine assembly, Industrial robot, Powerformer, Stator winding, Wave energy converter

Erik Hultman; Mats Leijon

2013-02-01T23:59:59.000Z

88

High Voltage GaN Schottky Rectifiers  

SciTech Connect

Mesa and planar GaN Schottky diode rectifiers with reverse breakdown voltages (V{sub RB}) up to 550V and >2000V, respectively, have been fabricated. The on-state resistance, R{sub ON}, was 6m{Omega}{center_dot} cm{sup 2} and 0.8{Omega}cm{sup 2}, respectively, producing figure-of-merit values for (V{sub RB}){sup 2}/R{sub ON} in the range 5-48 MW{center_dot}cm{sup -2}. At low biases the reverse leakage current was proportional to the size of the rectifying contact perimeter, while at high biases the current was proportional to the area of this contact. These results suggest that at low reverse biases, the leakage is dominated by the surface component, while at higher biases the bulk component dominates. On-state voltages were 3.5V for the 550V diodes and {ge}15 for the 2kV diodes. Reverse recovery times were <0.2{micro}sec for devices switched from a forward current density of {approx}500A{center_dot}cm{sup -2} to a reverse bias of 100V.

CAO,X.A.; CHO,H.; CHU,S.N.G.; CHUO,C.-C.; CHYI,J.-I.; DANG,G.T.; HAN,JUNG; LEE,C.-M.; PEARTON,S.J.; REN,F.; WILSON,R.G.; ZHANG,A.P.

1999-10-25T23:59:59.000Z

89

LOW-LOSS CABLE AND METHOD OF FABRICATION  

DOE Patents (OSTI)

A radiation-resistant coaxial electrical cable capable of carrying very small currents at high voltages with little leakage is described. The cable comprises an inner axial conductor separated from an outer coaxial tubular conductor by annular layer of fibrous silica insulation. The silica insulation is formed by leaching boron from spun horosilicate glass and then heat treating the silica at a high temperature.

McCarthy, R.L. et al.

1960-09-27T23:59:59.000Z

90

High-Pressure Fluid-Filled Cable Condition Assessment Through Electrical Impulse Testing of PSE&G 230-kV Service-Aged Cable  

Science Conference Proceedings (OSTI)

This report describes electrical and mechanical testing of a service-aged 230-kV high-pressure fluid-filled (HPFF) cable sample that was removed from a Public Service Electric & Gas (PSE&G) underground transmission line.

2008-11-26T23:59:59.000Z

91

Spark-plasma Sintering vs. High Voltage Electric Discharge ...  

Science Conference Proceedings (OSTI)

High voltage electric discharge consolidation (HVEDC) includes high axial pressure and discharge of the electrical energy stored in capacitors, thus enabling a ...

92

High-voltage technology for the LASL implosion-heating experiment  

SciTech Connect

The implosion-heating power supply uses four 125-kV generators in series. Each generator consists of a fast 125-kV pulse-forming network made up of capacitors attached to a 1m-wide parallel-plate transmission line which is fed through multiple cables from a 2.5- mu F, 0.5- mu H Marx bank charged to 180 kV. To simplify construction it was decided to do without oil or water for high- voltage insulation and grading. The developments described here are: (1) a low- inductance connection between the 125-kV capacitors and the parallel-plate transmission line using an elastomer gasket capable of holding 200 kV; (2) edge flashover prevention by ballooning'' the sheet insulation, by which a 10-cm edge extension of insulation is capable of withstanding a 200-kV pulse for several microseconds; (3) using the edge flashover for over-voltage prevention; (4) grading of voltage along insulators with conducting plastic sheets to prevent flashover at the load switches and cable connections; and (51 capacitively graded insulating supports for the Marx banks. (auth)

Hammel, J.E.; Henins, I.; Marshall, J.; Sherwood, A.R.

1973-01-01T23:59:59.000Z

93

Cascode buffer for monolithic voltage conversion operating at high input supply voltages  

E-Print Network (OSTI)

A high-to-low switching DC-DC converter that operates at input supply voltages up to two times as high as the maximum voltage permitted in a nanometer CMOS technology is proposed in this paper. The circuit technique is based on a cascode bridge that maintains the steady-state voltage differences among the terminals of all of the transistors within a range imposed by a specific fabrication technology. The proposed circuit technique permits the full integration of active and passive devices of a switching DC-DC converter with a high voltage conversion ratio in a standard low voltage CMOS process. An efficiency of 87.8 % is achieved for 3.6 volts to 0.9 volts conversion assuming

Volkan Kursun; Gerhard Schrom; Vivek K. De; Eby G. Friedman; Siva G. Narendra

2005-01-01T23:59:59.000Z

94

fault diagnosis of a high voltage transmission line using waveform ...  

E-Print Network (OSTI)

Oct 4, 2013 ... FAULT DIAGNOSIS OF A HIGH VOLTAGE TRANSMISSION LINE USING ... Fault types such as single line to ground, line to line, double line to ...

95

High Voltage Electric Discharge Consolidation of Tantalum Powders  

Science Conference Proceedings (OSTI)

Abstract Scope, The high voltage electric discharge consolidation (HVEDC) is a promising method of the volumetric-porous body manufacturing, which can be ...

96

(SPS) and High Voltage Electric Discharge Consolidation (HVEDC  

Science Conference Proceedings (OSTI)

Presentation Title, Inter-Particle Contact Phenomena in Spark-Plasma Sintering ( SPS) and High Voltage Electric Discharge Consolidation (HVEDC). Author(s) ...

97

(SPS) and High Voltage Electric Discharge Consolidation (HVEDC)  

Science Conference Proceedings (OSTI)

Presentation Title, Local Heat Balance in Spark-plasma Sintering (SPS) and High Voltage Electric Discharge Consolidation (HVEDC). Author(s), Eugene ...

98

Chronic Benzodiazepine Administration Potentiates High Voltage-Activated Calcium Currents  

E-Print Network (OSTI)

.aspetjournals.orgDownloadedfrom #12;other drugs of abuse has been reported to enhance high voltage-activated calcium channels (HVAs

Brand, Paul H.

99

Electrical system architecture having high voltage bus  

DOE Patents (OSTI)

An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

Hoff, Brian Douglas (East Peoria, IL); Akasam, Sivaprasad (Peoria, IL)

2011-03-22T23:59:59.000Z

100

A compact high voltage pulse generator  

SciTech Connect

A compact, easily transportable, pulse generator has been developed for a variety of applications that require a pulse duration in the range of 1 {mu} sec., voltages from 150 to 300 KV and current levels from 2,000 to 3,000 amps. The generator has a simple cylindrical configuration and modular construction to facilitate assembly and service. The generator may be operated single-pulse or repetitively at pulse repetition rates to 50 Hz in a burst mode.

Rohwein, G.J.; Babcock, S.R.

1994-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Evaluation of Medium-Voltage Cable Joints: Single-Phase, Three-Phase, and Branch Transition Joints  

Science Conference Proceedings (OSTI)

This report evaluates three single-phase transition joints, three three-phase trifurcating transition joints, and one three-phase trifurcating transition branch joint between ethylene propylene rubber (EPR) and paper-insulated lead-covered (PILC) 15-kV cables. Among installation parameters evaluated are time to install, complexity, skill required, ease of assembly, margin for error, and space needed for joint assembly and fabrication.

2003-05-19T23:59:59.000Z

102

Living and Working Safely Around High-Voltage Power Lines.  

Science Conference Proceedings (OSTI)

High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

United States. Bonneville Power Administration.

2001-06-01T23:59:59.000Z

103

Planar LTCC transformers for high voltage flyback converters.  

SciTech Connect

This paper discusses the design and use of low-temperature (850 C to 950 C) co-fired ceramic (LTCC) planar magnetic flyback transformers for applications that require conversion of a low voltage to high voltage (> 100V) with significant volumetric constraints. Measured performance and modeling results for multiple designs showed that the LTCC flyback transformer design and construction imposes serious limitations on the achievable coupling and significantly impacts the transformer performance and output voltage. This paper discusses the impact of various design factors that can provide improved performance by increasing transformer coupling and output voltage. The experiments performed on prototype units demonstrated LTCC transformer designs capable of greater than 2 kV output. Finally, the work investigated the effect of the LTCC microstructure on transformer insulation. Although this paper focuses on generating voltages in the kV range, the experimental characterization and discussion presented in this work applies to designs requiring lower voltage.

Schofield, Daryl (NASCENT Technology Inc. , Watertown, SD); Schare, Joshua M.; Glass, Sarah Jill; Roesler, Alexander William; Ewsuk, Kevin Gregory; Slama, George (NASCENT Technology Inc. , Watertown, SD); Abel, Dave (NASCENT Technology Inc. , Watertown, SD)

2007-06-01T23:59:59.000Z

104

Cable shield connecting device  

DOE Patents (OSTI)

A cable shield connecting device for installation on a high voltage cable of the type having a metallic shield, the device including a relatively conformable, looped metal bar for placement around a bared portion of the metallic shield to extend circumferentially around a major portion of the circumference of the metallic shield while being spaced radially therefrom, a plurality of relatively flexible metallic fingers affixed to the bar, projecting from the bar in an axial direction and spaced circumferentially along the bar, each finger being attached to the metallic shield at a portion located remote from the bar to make electrical contact with the metallic shield, and a connecting conductor integral with the bar.

Silva, Frank A. (Basking Ridge, NJ)

1979-01-01T23:59:59.000Z

105

Optically triggered high voltage switch network and method for switching a high voltage  

DOE Patents (OSTI)

An optically triggered solid state switch and method for switching a high voltage electrical current. A plurality of solid state switches (350) are connected in series for controlling electrical current flow between a compensation capacitor (112) and ground in a reactive power compensator (50, 50') that monitors the voltage and current flowing through each of three distribution lines (52a, 52b and 52c), which are supplying three-phase power to one or more inductive loads. An optical transmitter (100) controlled by the reactive power compensation system produces light pulses that are conveyed over optical fibers (102) to a switch driver (110') that includes a plurality of series connected optical triger circuits (288). Each of the optical trigger circuits controls a pair of the solid state switches and includes a plurality of series connected resistors (294, 326, 330, and 334) that equalize or balance the potential across the plurality of trigger circuits. The trigger circuits are connected to one of the distribution lines through a trigger capacitor (340). In each switch driver, the light signals activate a phototransistor (300) so that an electrical current flows from one of the energy reservoir capacitors through a pulse transformer (306) in the trigger circuit, producing gate signals that turn on the pair of serially connected solid state switches (350).

El-Sharkawi, Mohamed A. (Renton, WA); Andexler, George (Everett, WA); Silberkleit, Lee I. (Mountlake Terrace, WA)

1993-01-19T23:59:59.000Z

106

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage put under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1996-01-01T23:59:59.000Z

107

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 figs.

Shimer, D.W.; Lange, A.C.

1996-10-15T23:59:59.000Z

108

Cost-Effective Cable Insulation: Nanoclay Reinforced Ethylene-Propylene-Rubber for Low-Cost HVDC Cabling  

SciTech Connect

GENI Project: GE is developing new, low-cost insulation for high-voltage direct current (HVDC) electricity transmission cables. The current material used to insulate HVDC transmission cables is very expensive and can account for as much as 1/3 of the total cost of a high-voltage transmission system. GE is embedding nanomaterials into specialty rubber to create its insulation. Not only are these materials less expensive than those used in conventional HVDC insulation, but also they will help suppress excess charge accumulation. The excess charge left behind on a cable poses a major challenge for high-voltage insulation—if it’s not kept to a low level, it could ultimately lead the insulation to fail. GE’s low-cost insulation is compatible with existing U.S. cable manufacturing processes, further enhancing its cost effectiveness.

None

2012-02-24T23:59:59.000Z

109

High-voltage air-core pulse transformers  

SciTech Connect

General types of air core pulse transformers designed for high voltage pulse generation and energy transfer applications are discussed with special emphasis on pulse charging systems which operate up to the multi-megavolt range. The design, operation, dielectric materials, and performance are described. It is concluded that high voltage air core pulse transformers are best suited to applications outside the normal ranges of conventional magnetic core transformers. In general these include charge transfer at high power levels and fast pulse generation with comparatively low energy. When properly designed and constructed, they are capable of delivering high energy transfer efficiency and have demonstrated superior high voltage endurance. The principal disadvantage of high voltage air core transformers is that they are not generally available from commercial sources. Consequently, the potential user must become thoroughly familiar with all aspects of design, fabrication and system application before he can produce a high performance transformer system. (LCL)

Rohwein, G. J.

1981-01-01T23:59:59.000Z

110

Assessment and Testing of High-Pressure Fluid-Filled (HPFF) Cables  

Science Conference Proceedings (OSTI)

The Niagara Power Project of the New York Power Authority (NYPA) includes the Robert Moses Power Plant (RMPP), the Lewiston Pumping Generation Plant (LPGP) and a substation that connects the output of these facilities to the NYPA transmission system. Both of the power plants were built in 1961. The high-pressure fluid-filled (HPFF) cable systems at these two facilities have been in operation for more than 40 years. NYPA required an assessment of the condition and life expectancy of the HPFF cable systems...

2007-03-29T23:59:59.000Z

111

Power superconducting power transmission cable  

DOE Patents (OSTI)

The present invention is for a compact superconducting power transmission cable operating at distribution level voltages. The superconducting cable is a conductor with a number of tapes assembled into a subconductor. These conductors are then mounted co-planarly in an elongated dielectric to produce a 3-phase cable. The arrangement increases the magnetic field parallel to the tapes thereby reducing ac losses.

Ashworth, Stephen P. (Cambridge, GB)

2003-01-01T23:59:59.000Z

112

Nanodielectrics for Underground Distribution Cables and Cable Systems  

Science Conference Proceedings (OSTI)

The Electric Power Research Institute (EPRI) early recognized the potential for nanotechnology in power distribution and started a program in 2003 to explore the possibilities of using the technology to enhance the properties of high-voltage cable dielectrics based on polyethylene and ethylene-propylene rubber. In a broad sense, the research is developing methods to incorporate nanoparticles into insulating compounds. The specific efforts to date have focused on improved dielectric breakdown strength. Co...

2010-12-21T23:59:59.000Z

113

Optical control system for high-voltage terminals  

DOE Patents (OSTI)

An optical control system for the control of devices in the terminal of an electrostatic accelerator includes a laser that is modulated by a series of preselected codes produced by an encoder. A photodiode receiver is placed in the laser beam at the high-voltage terminal of an electrostatic accelerator. A decoder connected to the photodiode decodes the signals to provide control impulses for a plurality of devices at the high voltage of the terminal.

Bicek, John J. (Tinley Park, IL)

1978-01-01T23:59:59.000Z

114

Available Technologies: High Voltage Compatible, Fully ...  

APPLICATIONS OF TECHNOLOGY: Small pixel, scientific CCDs where good point spread function (PSF) is required; High quantum efficiency direct detection ...

115

Lipon Coatings for High Voltage and High Temperature Li-Ion ...  

use of high-capacity and high-voltage cathode materials, but charging to voltages approaching 4.5-5V invariably causes rapid loss of capacity with cycling.

116

"Flexible aerogel as a superior thermal insulation for high temperature superconductor cable applications"  

Science Conference Proceedings (OSTI)

High temperature superconducting (HTS) cables are an advanced technology that can both strengthen and improve the national electrical distribution infrastructure. HTS cables require sufficient cooling to overcome inherent low temperature heat loading. Heat loads are minimized by the use of cryogenic envelopes or cryostats. Cryostats require improvement in efficiency, reliability, and cost reduction to meet the demanding needs of HTS conductors (1G and 2G wires). Aspen Aerogels has developed a compression resistant aerogel thermal insulation package to replace compression sensitive multi-layer insulation (MLI), the incumbent thermal insulation, in flexible cryostats for HTS cables. Oak Ridge National Laboratory tested a prototype aerogel package in a lab-scale pipe apparatus to measure the rate of heat invasion. The lab-scale pipe test results of the aerogel solution will be presented and directly compared to MLI. A compatibility assessment of the aerogel material with HTS system components will also be presented. The aerogel thermal insulation solution presented will meet the demanding needs of HTS cables.

White, Shannon O. [Aspen Aerogel, Inc.; Demko, Jonathan A [ORNL; Tomich, A. [Aspen Aerogel, Inc.

2010-01-01T23:59:59.000Z

117

High voltage electrical amplifier having a short rise time  

DOE Patents (OSTI)

A circuit, comprising an amplifier and a transformer is disclosed that produces a high power pulse having a fast response time, and that responds to a digital control signal applied through a digital-to-analog converter. The present invention is suitable for driving a component such as an electro-optic modulator with a voltage in the kilovolt range. The circuit is stable at high frequencies and during pulse transients, and its impedance matching circuit matches the load impedance with the output impedance. The preferred embodiment comprises an input stage compatible with high-speed semiconductor components for amplifying the voltage of the input control signal, a buffer for isolating the input stage from the output stage; and a plurality of current amplifiers connected to the buffer. Each current amplifier is connected to a field effect transistor (FET), which switches a high voltage power supply to a transformer which then provides an output terminal for driving a load. The transformer comprises a plurality of transmission lines connected to the FETs and the load. The transformer changes the impedance and the voltage of the output. The preferred embodiment also comprises a low voltage power supply for biasing the FETs at or near an operational voltage. 8 figs.

Christie, D.J.; Dallum, G.E.

1989-12-07T23:59:59.000Z

118

High voltage electrical amplifier having a short rise time  

DOE Patents (OSTI)

A circuit, comprising an amplifier and a transformer is disclosed that produces a high power pulse having a fast response time, and that responds to a digital control signal applied through a digital-to-analog converter. The present invention is suitable for driving a component such as an electro-optic modulator with a voltage in the kilovolt range. The circuit is stable at high frequencies and during pulse transients, and its impedance matching circuit matches the load impedance with the output impedance. The preferred embodiment comprises an input stage compatible with high-speed semiconductor components for amplifying the voltage of the input control signal, a buffer for isolating the input stage from the output stage; and a plurality of current amplifiers connected to the buffer. Each current amplifier is connected to a field effect transistor (FET), which switches a high voltage power supply to a transformer which then provides an output terminal for driving a load. The transformer comprises a plurality of transmission lines connected to the FETs and the load. The transformer changes the impedance and voltage of the output. The preferred embodiment also comprises a low voltage power supply for biasing the FETs at or near an operational voltage.

Christie, David J. (Pleasanton, CA); Dallum, Gregory E. (Livermore, CA)

1991-01-01T23:59:59.000Z

119

Planar LTCC transformers for high voltage flyback converters: Part II.  

Science Conference Proceedings (OSTI)

This paper is a continuation of the work presented in SAND2007-2591 'Planar LTCC Transformers for High Voltage Flyback Converters'. The designs in that SAND report were all based on a ferrite tape/dielectric paste system originally developed by NASCENTechnoloy, Inc, who collaborated in the design and manufacturing of the planar LTCC flyback converters. The output/volume requirements were targeted to DoD application for hard target/mini fuzing at around 1500 V for reasonable primary peak currents. High voltages could be obtained but with considerable higher current. Work had begun on higher voltage systems and is where this report begins. Limits in material properties and processing capabilities show that the state-of-the-art has limited our practical output voltage from such a small part volume. In other words, the technology is currently limited within the allowable funding and interest.

Schofield, Daryl (NASCENTechnology, Inc., Watertown, SD); Schare, Joshua M., Ph.D.; Slama, George (NASCENTechnology, Inc., Watertown, SD); Abel, David (NASCENTechnology, Inc., Watertown, SD)

2009-02-01T23:59:59.000Z

120

Design & Fabrication of a High-Voltage Photovoltaic Cell  

DOE Green Energy (OSTI)

Silicon photovoltaic (PV) cells are alternative energy sources that are important in sustainable power generation. Currently, applications of PV cells are limited by the low output voltage and somewhat low efficiency of such devices. In light of this fact, this project investigates the possibility of fabricating high-voltage PV cells on float-zone silicon wafers having output voltages ranging from 50 V to 2000 V. Three designs with different geometries of diffusion layers were simulated and compared in terms of metal coverage, recombination, built-in potential, and conduction current density. One design was then chosen and optimized to be implemented in the final device design. The results of the simulation serve as a feasibility test for the design concept and provide supportive evidence of the effectiveness of silicon PV cells as high-voltage power supplies.

Felder, Jennifer; /North Carolina State U. /SLAC

2012-09-05T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

High voltage series connected tandem junction solar battery  

DOE Patents (OSTI)

A high voltage series connected tandem junction solar battery which comprises a plurality of strips of tandem junction solar cells of hydrogenated amorphous silicon having one optical path and electrically interconnected by a tunnel junction. The layers of hydrogenated amorphous silicon, arranged in a tandem configuration, can have the same bandgap or differing bandgaps. The tandem junction strip solar cells are series connected to produce a solar battery of any desired voltage.

Hanak, Joseph J. (Lawrenceville, NJ)

1982-01-01T23:59:59.000Z

122

Method and apparatus for electrical cable testing by pulse-arrested spark discharge  

DOE Patents (OSTI)

A method for electrical cable testing by Pulse-Arrested Spark Discharge (PASD) uses the cable response to a short-duration high-voltage incident pulse to determine the location of an electrical breakdown that occurs at a defect site in the cable. The apparatus for cable testing by PASD includes a pulser for generating the short-duration high-voltage incident pulse, at least one diagnostic sensor to detect the incident pulse and the breakdown-induced reflected and/or transmitted pulses propagating from the electrical breakdown at the defect site, and a transient recorder to record the cable response. The method and apparatus are particularly useful to determine the location of defect sites in critical but inaccessible electrical cabling systems in aging aircraft, ships, nuclear power plants, and industrial complexes.

Barnum, John R. (Albuquerque, NM); Warne, Larry K. (Albuquerque, NM); Jorgenson, Roy E. (Albuquerque, NM); Schneider, Larry X. (Albuquerque, NM)

2005-02-08T23:59:59.000Z

123

Gaseous insulators for high voltage electrical equipment  

DOE Patents (OSTI)

Gaseous insulators comprise compounds having high attachment cross sections for electrons having energies in the 0-1.3 electron volt range. Multi-component gaseous insulators comprise compounds and mixtures having overall high electron attachment cross sections in the 0-1.3 electron volt range and moderating gases having high cross sections for inelastic interactions with electrons of energies 1-4 electron volts. Suitable electron attachment components include hexafluorobutyne, perfluorobutene-2, perfluorocyclobutane, perfluorodimethylcyclobutane, perfluorocyclohexene, perfluoromethylcyclohexane, hexafluorobutadiene, perfluoroheptene-1 and hexafluoroazomethane. Suitable moderating gases include N.sub.2, CO, CO.sub.2 and H.sub.2. The gaseous insulating mixture can also contain SF.sub.6, perfluoropropane and perfluorobenzene.

Christophorou, Loucas G. (Oak Ridge, TN); James, David R. (Knoxville, TN); Pace, Marshall O. (Knoxville, TN); Pai, Robert Y. (Concord, TN)

1981-01-01T23:59:59.000Z

124

Gaseous insulators for high voltage electrical equipment  

DOE Patents (OSTI)

Gaseous insulators comprise compounds having high attachment cross sections for electrons having energies in the 0-1.3 electron volt range. Multi-component gaseous insulators comprise compounds and mixtures having overall high electron attachment cross sections in the 0-1.3 electron volt range and moderating gases having high cross sections for inelastic interactions with electrons of energies 1-4 electron volts. Suitable electron attachment components include hexafluorobutyne, perfluorobutene-2, perfluorocyclobutane, perfluorodimethylcyclobutane, perfluorocyclohexene, perfluoromethylcyclohexane, hexafluorobutadiene, perfluoroheptene-1 and hexafluoroazomethane. Suitable moderating gases include N.sub.2, CO, CO.sub.2 and H.sub.2. The gaseous insulating mixture can also contain SF.sub.6, perfluoropropane and perfluorobenzene.

Christophorou, Loucas G. (Oak Ridge, TN); James, David R. (Knoxville, TN); Pace, Marshall O. (Knoxville, TN); Pai, Robert Y. (Concord, TN)

1979-01-01T23:59:59.000Z

125

Solid state safety jumper cables  

DOE Patents (OSTI)

This invention consists of solid state jumper cables for connecting two batteries in parallel, having two bridge rectifiers for developing a reference voltage, a four-input decoder for determining which terminals are to be connected based on a comparison of the voltage at each of the four terminals to the reference voltage, and a pair of relays for effecting the correct connection depending on the determination of the decoder. No connection will be made unless only one terminal of each battery has a higher voltage than the reference voltage, indicating positive'' terminals, and one has a lower voltage than the reference voltage, indicating C{sup 2} negative terminals, and that, therefore, the two high voltage terminals may be connected and the two lower voltage terminals may be connected. Current flows once the appropriate relay device is closed. The relay device is preferably a MOSFET (metal oxide semiconductor field effect transistor) combined with a series array of photodiodes that develop MOSFET gate-closing potential when the decoder output causes an LED to light.

Kronberg, J.W.

1991-01-22T23:59:59.000Z

126

Solid state safety jumper cables  

DOE Patents (OSTI)

Solid state jumper cables for connecting two batteries in parallel, having two bridge rectifiers for developing a reference voltage, a four-input decoder for determining which terminals are to be connected based on a comparison of the voltage at each of the four terminals to the reference voltage, and a pair of relays for effecting the correct connection depending on the determination of the decoder. No connection will be made unless only one terminal of each battery has a higher voltage than the reference voltage, indicating positive'' terminals, and one has a lower voltage than the reference voltage, indicating negative'' terminals, and that, therefore, the two high voltage terminals may be connected and the two lower voltage terminals may be connected. Current flows once the appropriate relay device is closed. The relay device is preferably a MOSFET (metal oxide semiconductor field effect transistor) combined with a series array of photodiodes that develop MOSFET gate-closing potential when the decoder output causes an LED to light.

Kronberg, J.W.

1993-02-23T23:59:59.000Z

127

Solid state safety jumper cables  

DOE Patents (OSTI)

Solid state jumper cables for connecting two batteries in parallel, having two bridge rectifiers for developing a reference voltage, a four-input decoder for determining which terminals are to be connected based on a comparison of the voltage at each of the four terminals to the reference voltage, and a pair of relays for effecting the correct connection depending on the determination of the decoder. No connection will be made unless only one terminal of each battery has a higher voltage than the reference voltage, indicating "positive" terminals, and one has a lower voltage than the reference voltage, indicating "negative" terminals, and that, therefore, the two high voltage terminals may be connected and the two lower voltage terminals may be connected. Current flows once the appropriate relay device is closed. The relay device is preferably a MOSFET (metal oxide semiconductor field effect transistor) combined with a series array of photodiodes that develop MOSFET gate-closing potential when the decoder output causes an LED to light.

Kronberg, James W. (353 Church Rd., Beech Island, SC 29841)

1993-01-01T23:59:59.000Z

128

Solid state safety jumper cables  

DOE Patents (OSTI)

This invention consists of solid state jumper cables for connecting two batteries in parallel, having two bridge rectifiers for developing a reference voltage, a four-input decoder for determining which terminals are to be connected based on a comparison of the voltage at each of the four terminals to the reference voltage, and a pair of relays for effecting the correct connection depending on the determination of the decoder. No connection will be made unless only one terminal of each battery has a higher voltage than the reference voltage, indicating ``positive`` terminals, and one has a lower voltage than the reference voltage, indicating C{sup 2} negative terminals, and that, therefore, the two high voltage terminals may be connected and the two lower voltage terminals may be connected. Current flows once the appropriate relay device is closed. The relay device is preferably a MOSFET (metal oxide semiconductor field effect transistor) combined with a series array of photodiodes that develop MOSFET gate-closing potential when the decoder output causes an LED to light.

Kronberg, J.W.

1991-01-22T23:59:59.000Z

129

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1997-01-01T23:59:59.000Z

130

E-beam high voltage switching power supply  

DOE Patents (OSTI)

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360{degree}/n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load. 7 figs.

Shimer, D.W.; Lange, A.C.

1997-03-11T23:59:59.000Z

131

The commercial development of water repellent coatings for high voltage transmission lines  

SciTech Connect

The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy?s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.

Hunter, S. R. [ORNL] [ORNL; Daniel, A. [Southwire Company] [Southwire Company

2013-10-31T23:59:59.000Z

132

The commercial development of water repellent coatings for high voltage transmission lines  

SciTech Connect

The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.

Hunter, Scott Robert [ORNL] [ORNL

2013-10-01T23:59:59.000Z

133

Experiment Hazard Class 13.0 - High Voltage  

NLE Websites -- All DOE Office Websites (Extended Search)

3.0 - High Voltage 3.0 - High Voltage Applicability This hazard classification applies to all experiments involving the use of High Voltage Equipment. Other hazard classifications and their associated hazard controls may also apply to experiments in this hazard class. The inspection of electric equipment is covered under the APS Policy For User Electric Equipment Inspections. NOTE: Unless required Argonne training has been completed, users are not authorized to perform electrical work. Experiment Category All Hazard Class 13 experiments are categorized as medium risk experiments. Experiment Hazard Control Verification Statements Engineered Controls - Determined by review and results of a DEEI inspection of the equipment. Procedural Controls - Determined by review and results of a DEEI

134

Ultra-compact Marx-type high-voltage generator  

DOE Patents (OSTI)

An ultra-compact Marx-type high-voltage generator includes individual high-performance components that are closely coupled and integrated into an extremely compact assembly. In one embodiment, a repetitively-switched, ultra-compact Marx generator includes low-profile, annular-shaped, high-voltage, ceramic capacitors with contoured edges and coplanar extended electrodes used for primary energy storage; low-profile, low-inductance, high-voltage, pressurized gas switches with compact gas envelopes suitably designed to be integrated with the annular capacitors; feed-forward, high-voltage, ceramic capacitors attached across successive switch-capacitor-switch stages to couple the necessary energy forward to sufficiently overvoltage the spark gap of the next in-line switch; optimally shaped electrodes and insulator surfaces to reduce electric field stresses in the weakest regions where dissimilar materials meet, and to spread the fields more evenly throughout the dielectric materials, allowing them to operate closer to their intrinsic breakdown levels; and uses manufacturing and assembly methods to integrate the capacitors and switches into stages that can be arranged into a low-profile Marx generator.

Goerz, David A. (Brentwood, CA); Wilson, Michael J. (Modesto, CA)

2000-01-01T23:59:59.000Z

135

HVDC Cables Interest Group: Summary of 2012 Activities  

Science Conference Proceedings (OSTI)

A diverse international group of participants has been assembled, with special knowledge and interests in high-voltage direct-current (HVDC) cable technology applications. A forum has been developed for the free exchange of technical information between leading power utility engineers and researchers who are actively engaged in the practical world of HVDC system applications as well as those planning future R&D activities. This report describes results of the first year of the HVDC Cables ...

2013-06-28T23:59:59.000Z

136

High voltage gas insulated transmission line with continuous particle trapping  

DOE Patents (OSTI)

This invention provides a novel high voltage gas insulated transmission line utilizing insulating supports spaced at intervals with snap-in means for supporting a continuous trapping apparatus and said trapping apparatus having perforations and cutouts to facilitate trapping of contaminating particles and system flexibility.

Cookson, Alan H. (Pittsburgh, PA); Dale, Steinar J. (Monroeville, PA)

1983-01-01T23:59:59.000Z

137

Control Techniques to Eliminate Voltage Emergencies in High Performance Processors  

E-Print Network (OSTI)

negligible impact on perfor­ mance and energy. With the ITRS roadmap predicting aggres­ sive drops in supply. At present it is difficult to design a high quality, low impedance power supply system, and industry trends in current variability, often re­ ferred to as the dI/dt problem, can cause supply voltage fluc­ tuations

Martonosi, Margaret

138

Control Techniques to Eliminate Voltage Emergencies in High Performance Processors  

E-Print Network (OSTI)

negligible impact on perfor- mance and energy. With the ITRS roadmap predicting aggres- sive drops in supply. At present it is difficult to design a high quality, low impedance power supply system, and industry trends in current variability, often re- ferred to as the dI/dt problem, can cause supply voltage fluc- tuations

Gupta, Rajiv

139

High Voltage Laboratory Testing of Femtosecond Laser Lightning Diversion  

Science Conference Proceedings (OSTI)

Lightning strikes cost the electric power industry an estimated 1 billion dollars annually in damage and lost revenue. One possible way of protecting critical and susceptible facilities from lightning strikes is to use lasers to trigger and divert lightning along a predetermined path. This report describes laboratory research on the use of ultrashort UV pulses and near IR pulses to trigger high voltage discharge.

1998-12-09T23:59:59.000Z

140

Current isolating epitaxial buffer layers for high voltage photodiode array  

DOE Patents (OSTI)

An array of photodiodes in series on a common semi-insulating substrate has a non-conductive buffer layer between the photodiodes and the semi-insulating substrate. The buffer layer reduces current injection leakage between the photodiodes of the array and allows optical energy to be converted to high voltage electrical energy.

Morse, Jeffrey D. (Martinez, CA); Cooper, Gregory A. (Pleasant Hill, CA)

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

High voltage bipolar-CMOS structure using porous silicon  

DOE Patents (OSTI)

A method for integrating a silicon-on-insulator device and a bulk bipolar device on a semiconductor body. The invention simultaneously forms the two regions for the silicon-on-insulator device and the bipolar device. The invention enables a high voltage CMOS power device to be located on the same chip as a bipolar logic device enabling smart power devices.

Guilinger, T.R.; Kelly, M.J.; Tsao, S.S.

1990-01-01T23:59:59.000Z

142

Fiber Optic Cables in Overhead Transmission Corridors: A State-of-the-Art Review  

Science Conference Proceedings (OSTI)

Many electric utilities are installing high capacity fiber optic cables and wires on their high voltage lines to satisfy their own internal communication needs and to gain additional revenues by leasing excess capacity to telecommunication network providers. This report presents a review and evaluation of the state-of-the-art in using fiber optic technology in high voltage corridors.

1997-11-26T23:59:59.000Z

143

Cable Diagnostic Focused Initiative  

SciTech Connect

This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online knowledge based system (KBS) that helps utilities select the most effective diagnostic technologies for a given cable circuit and circuit conditions.

Hartlein, R.A.; Hampton, R.N.

2010-12-30T23:59:59.000Z

144

Design Concepts for a Superconducting Cable  

Science Conference Proceedings (OSTI)

Superconducting cables carry higher currents and, depending upon the design, can experience substantially lower transmission losses than conventional cables. This report discusses previous approaches to designing superconducting cables, describes the technical issues that must be considered when designing a high-temperature superconductor (HTS) cable, and presents several design concepts for an HTS cable.

1994-09-28T23:59:59.000Z

145

High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1995-01-01T23:59:59.000Z

146

High voltage dc--dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.

Shimer, D.W.; Lange, A.C.

1995-05-23T23:59:59.000Z

147

Field Guide: Compressors for High-Voltage Circuit Breakers  

Science Conference Proceedings (OSTI)

High-voltage circuit breakers (HVCBs) perform essential protection and control functions on power transmission networks. Circuit breakers have multiple components that must operate in concert in order for the breaker to perform properly. If one component, such as the air or hydraulic system, does not operate correctly, the circuit breaker may misoperate or fail, possibly resulting in equipment damage or an outageboth expensive consequences. To help utilities prevent such undesirable events, this field gu...

2010-12-22T23:59:59.000Z

148

Field Guide: Compressors for High-Voltage Circuit Breakers  

Science Conference Proceedings (OSTI)

High-voltage circuit breakers (HVCBs) perform essential protection and control functions on power transmission networks. Circuit breakers have multiple components that must operate in concert in order for the breaker to perform properly. If one component, such as the air or hydraulic system, does not operate correctly, the circuit breaker may misoperate or fail, possibly resulting in equipment damage or an outage—both expensive consequences. To help ...

2012-12-14T23:59:59.000Z

149

High Voltage Direct Current (HVDC) Transmission Reference Book  

Science Conference Proceedings (OSTI)

The EPRI High-Voltage Direct Current (HVDC) Transmission Reference Book is a state-of-the-art guidebook that provides transmission companies with a comprehensive, single source of technical information and guidance for designing, building, operating, and extending the life of HVDC transmission systems. The book joins the landmark series of EPRI power delivery reference books. These comprehensive guidebooks—each printed with a distinctive colored cover—document and distill the ...

2012-12-31T23:59:59.000Z

150

High-Voltage Direct Current Line Conductor Optimization  

Science Conference Proceedings (OSTI)

Overhead transmission lines are designed to last for 40 years. Many ac lines in service today in North America are 70 or more years old. This survival rate is a result of conservative utility design practices and detailed product specifications. This reliability record has occurred despite a wide range of conductor types and sizes. In the present transmission system, there are far fewer high-voltage direct current (HVDC) lines, but those that have been designed and built have been similarly successful in...

2011-12-21T23:59:59.000Z

151

Field Guide: High-Voltage Circuit Breaker Compressors – 2013 Update  

Science Conference Proceedings (OSTI)

High-voltage circuit breakers (HVCBs) perform essential protection and control functions on power transmission networks. Circuit breaker mechanisms have multiple components that must operate in concert in order for the breaker to perform properly. If one component, such as the air or hydraulic system, does not operate correctly, the circuit breaker may mis-operate or fail. A circuit breaker mis-operation may cause equipment damage and outages—both ...

2013-12-19T23:59:59.000Z

152

Advanced Voltage Control Strategies for High Penetration of Distributed Generation  

Science Conference Proceedings (OSTI)

This research addresses advanced voltage control strategies for inverter-connected distributed generation. The emphasis is on photovoltaic (PV) generation, and results also apply to distributed wind, fuel cells, micro-turbines, and battery systems that are connected to the grid through an inverter. In related work, the Electric Power Research Institute (EPRI) identified a set of high-priority functions for distributed generation. These included reactive power control such as intelligent and autonomous vo...

2010-12-31T23:59:59.000Z

153

An Examination of the Potential for Nano-Composites in the Formulation of HV Cable Insulation  

Science Conference Proceedings (OSTI)

Promising results have been achieved in EPRI research to develop and evaluate a new dielectric for high voltage (HV) and extra high voltage (EHV) extruded dielectric cable. The new dielectrica polymer based on nanotechnologyhas shown outstanding performance in critical properties related to higher design stress, superior defect tolerance, and reduced losses.

2005-11-17T23:59:59.000Z

154

HVDC Cable Technology Assessment and DC versus AC Cables: State of the Science  

Science Conference Proceedings (OSTI)

Development and application of voltage-source converters and cross-linked polyethylene (XLPE)-insulated cables suitable for dc operation have accelerated the use of HVDC cables for land as well as underwater applications. There are many recent and planned installations that use these technologies or the long-established paper-insulated cable technology that has been used for long underwater cables for more than 50 years.This report describes these transmission cable types and their ...

2012-12-12T23:59:59.000Z

155

Fiber optic current monitor for high-voltage applications  

DOE Patents (OSTI)

A current monitor which derives its power from the conductor being measured for bidirectionally measuring the magnitude of current (from DC to above 50 khz) flowing through a conductor across which a relatively high level DC voltage is applied, includes a pair of identical transmitter modules connected in opposite polarity to one another in series with the conductor being monitored, for producing from one module a first light signal having an intensity directly proportional to the magnitude of current flowing in one direction through the conductor during one period of time, and from the other module a second light signal having an intensity directly proportional to the magnitude of current flowing in the opposite direction through the conductor during another period of time, and a receiver located in a safe area remote from the high voltage area for receiving the first and second light signals, and converting the same to first and second voltage signals having levels indicative of the magnitude of current being measured at a given time. 6 figs.

Renda, G.F.

1992-04-21T23:59:59.000Z

156

Advanced Gate Drive for the SNS High Voltage Converter Modulator  

SciTech Connect

SLAC National Accelerator Laboratory is developing a next generation H-bridge switch plate [1], a critical component of the SNS High Voltage Converter Modulator [2]. As part of that effort, a new IGBT gate driver has been developed. The drivers are an integral part of the switch plate, which are essential to ensuring fault-tolerant, high-performance operation of the modulator. The redesigned driver improves upon the existing gate drive in several ways. The new gate driver has improved fault detection and suppression capabilities; suppression of shoot-through and over-voltage conditions, monitoring of dI/dt and Vce(sat) for fast over-current detection and suppression, and redundant power isolation are some of the added features. In addition, triggering insertion delay is reduced by a factor of four compared to the existing driver. This paper details the design and performance of the new IGBT gate driver. A simplified schematic and description of the construction are included. The operation of the fast over-current detection circuits, active IGBT over-voltage protection circuit, shoot-through prevention circuitry, and control power isolation breakdown detection circuit are discussed.

Nguyen, M.N.; Burkhart, C.; Kemp, M.A.; /SLAC; Anderson, D.E.; /Oak Ridge

2009-05-07T23:59:59.000Z

157

High voltage design structure for high temperature superconducting device  

DOE Patents (OSTI)

In accordance with the present invention, modular corona shields are employed in a HTS device to reduce the electric field surrounding the HTS device. In a exemplary embodiment a fault current limiter module in the insulation region of a cryogenic cooling system has at least one fault current limiter set which employs a first corona shield disposed along the top portion of the fault current limiter set and is electrically coupled to the fault current limiter set. A second corona shield is disposed along the bottom portion of the fault current limiter set and is electrically coupled to the fault current limiter set. An insulation barrier is disposed within the insulation region along at least one side of the fault current limiter set. The first corona shield and the second corona shield act together to reduce the electric field surrounding the fault limiter set when voltage is applied to the fault limiter set.

Tekletsadik, Kasegn D. (Rexford, NY)

2008-05-20T23:59:59.000Z

158

Cable System Technology Review of XLPE EHV Cables: 220 kV to 500 kV  

Science Conference Proceedings (OSTI)

Utilities in North America are now evaluating the first long-length circuits of extruded cross-linked polyethylene (XLPE) cable systems containing many joints at rated voltages 220 kV, 230 kV, and 345 kV. Of interest is whether the design, manufacture, and installation of XLPE extra-high-voltage (EHV) cable systems has been sufficiently demonstrated to satisfy utilities that it can provide reliable service for their particular applications. This report reviews the worldwide state of the art, gives method...

2002-12-16T23:59:59.000Z

159

Distribution System Voltage Performance Analysis for High-Penetration Photovoltaics  

DOE Green Energy (OSTI)

This report examines the performance of commonly used distribution voltage regulation methods under reverse power flow.

Liu, E.; Bebic, J.

2008-02-01T23:59:59.000Z

160

Triaxial HTS Cable for the AEP Bixby Project  

Science Conference Proceedings (OSTI)

Ultera has installed a single 200-meter long high temperature superconducting (HTS) 3-phase triaxial design cable at the American Electric Power (AEP) Bixby substation in Columbus, Ohio. The cable connects a 132/13.8 kV transformer to the distribution switchgear serving seven outgoing circuits. It was designed to carry 3000 Arms. Testing of 3- to 5-meter length prototype cables, including a 5-meter prototype with full scale terminations tested at ORNL was conducted prior to the manufacture and installation of the AEP triaxial cable. These prototypes were used to demonstrate the crucial operating conditions including steady state operation at the 3000 Arms design current, high voltage operation, high voltage withstand and 110 kV impulse, and overcurrent fault capability. A summary of the results from the thermal analysis and testing conducted by Ultera and ORNL will be presented. Some analysis of the cable thermal-hydraulic response based on the testing that were used to determine some of the cable cryogenic system requirements are also presented.

Demko, Jonathan A [ORNL; Gouge, Michael J [ORNL; Lindsay, David T [ORNL; Roden, Mark L [ORNL; Tolbert, Jerry Carlton [ORNL

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

STUDY OF ACCELERATED AGING OF 15 kV XLPE AND EPR CABLE INSULATION BY SWITCHING IMPULSES AND ELEVATED AC VOLTAGE.  

E-Print Network (OSTI)

?? Accelerated aging of 15 kV Cross-linked Polyethylene (XLPE) and Ethylene Propylene Rubber (EPR) power cables was carried out in the experiments set for the… (more)

Cao, Linfeng

2010-01-01T23:59:59.000Z

162

High Power, High Voltage FETs in Linear Applications: A User's Perspective  

SciTech Connect

The specifications of the current crop of highpower, high-voltage field-effect transistors (FETs) can lure a designer into employing them in high-voltage DC equipment. Devices with extremely low on-resistance and very high power ratings are available from several manufacturers. However, our experience shows that high-voltage, linear operation of these devices at near-continuous duty can present difficult reliability challenges at stress levels well-below their published specifications. This paper chronicles the design evolution of a 600 volt, 8 ampere shunt regulator for use with megawatt-class radio transmitters, and presents a final design that has met its reliability criteria.

N. Greenough, E. Fredd, S. DePasquale

2009-09-21T23:59:59.000Z

163

Induction of nuclear fission by high-voltage application  

E-Print Network (OSTI)

In nuclear power generation, fissile materials are mainly used. For example, $U^{235}$ is fissile and therefore quite essential for use of nuclear energy. However, the material $U^{235}$ has very small natural abundance less than 1 %. We should seek possibility of utilizing fissionable materials such as $U^{238}$ because natural abundance of such fissionable materials is generally much larger than fissile ones. In this paper, we show that thermal neutrons with vanishing kinetic energy can induce nuclear fission when high voltage is applied to fissionable materials. To obtain this result, we use the liquid-drop model for nuclei. Finally, we propose how fissionable materials can be utilized.

Hirokazu Maruyama

2007-11-20T23:59:59.000Z

164

Worldwide reliability surveys of high voltage circuit breakers  

Science Conference Proceedings (OSTI)

This article reports on the results of two CIGRE 13.06 Working Group worldwide surveys of the reliability of high voltage circuit breakers, 63 kV and above. The first inquiry included 78,000 breaker-years of ``in service data`` from 102 utilities in 22 countries during the years 1974--1977 and included all interrupting technologies. The second inquiry included 70,708 breaker-years from 132 utilities in 22 countries for the years 1988--1991 and only included single-pressure SF6 breakers, because this is what most utilities are now buying. Thirty-one US utilities submitted data.

Heising, C.R.

1995-05-01T23:59:59.000Z

165

Self-monitoring high voltage transmission line suspension insulator  

DOE Patents (OSTI)

A high voltage transmission line suspension insulator (18 or 22) which monitors its own dielectric integrity. A dielectric rod (10) has one larger diameter end fitting attachable to a transmission line and another larger diameter end fitting attachable to a support tower. The rod is enclosed in a dielectric tube (14) which is hermetically sealed to the rod's end fittings such that a liquidtight space (20) is formed between the rod and the tube. A pressurized dielectric liquid is placed within that space. A discoloring dye placed within this space is used to detect the loss of the pressurized liquid.

Stemler, Gary E. (Vancouver, WA); Scott, Donald N. (Vancouver, WA)

1981-01-01T23:59:59.000Z

166

High Voltage Direct Current Live Line and Insulator Testing  

Science Conference Proceedings (OSTI)

This report has two main parts. The focus of the first part is on live work in overhead high-voltage direct current (HVDC) lines operating above 100 kV dc. It does not address issues related to lines for electric transport that typically operate below 60 kV dc worldwide. In addition, this first part of the report is not a detailed treatise on live work but, rather, addresses the main issues related to dc live work. More detailed information on the general topic of live work can be found in the references...

2011-12-23T23:59:59.000Z

167

High-Voltage Power Supply System for Laser Isotope Separation  

SciTech Connect

This report presents several concepts for Laser High-Voltage Power Supply (HVPS) Systems for a Laser Isotope Separation facility. Selection of equipments and their arrangement into operational systems is based on proven designs and on application concepts now being developed. This report has identified a number of alternative system arrangements and has provided preliminary cost estimates for each. The report includes a recommendation for follow-on studies that will further define the optimum Laser HVPS Systems. Brief descriptions are given of Modulator/Regulator circuit trade-offs, system control interfaces, and their impact on costs.

Ketaily, E.C.; Buckner, R.P.; Uhrik, R.L.

1979-06-26T23:59:59.000Z

168

An accurate continuous calibration system for high voltage current transformer  

SciTech Connect

A continuous calibration system for high voltage current transformers is presented in this paper. The sensor of this system is based on a kind of electronic instrument current transformer, which is a clamp-shape air core coil. This system uses an optical fiber transmission system for its signal transmission and power supply. Finally the digital integrator and fourth-order convolution window algorithm as error calculation methods are realized by the virtual instrument with a personal computer. It is found that this system can calibrate a high voltage current transformer while energized, which means avoiding a long calibrating period in the power system and the loss of power metering expense. At the same time, it has a wide dynamic range and frequency band, and it can achieve a high accuracy measurement in a complex electromagnetic field environment. The experimental results and the on-site operation results presented in the last part of the paper, prove that it can reach the 0.05 accuracy class and is easy to operate on site.

Tong Yue; Li Binhong [College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074, Hubei Province (China)

2011-02-15T23:59:59.000Z

169

Condition Assessment of 138-kV Iwilei-Archer High-Pressure Fluid-Filled Cable System of Hawaiian Electric Company  

Science Conference Proceedings (OSTI)

High-pressure fluid-filled (HPFF) transmission cable systems are characterized by an exceedingly long life, with well-maintained integrity of the pipe and operating pressure. However, some failures have been encountered in the past 15 years, probably due to advancing age and harder use. The cable systemswhich are composed of the cable, splices, terminations, trifurcators, pumping plants, risers, and so onshould be adequately maintained and routinely inspected.

2011-04-13T23:59:59.000Z

170

Dubal Cell Voltage Drop Initiatives towards Low Energy High ...  

Science Conference Proceedings (OSTI)

About this Abstract. Meeting, 2014 TMS Annual Meeting & Exhibition. Symposium , Aluminum Reduction Technology. Presentation Title, DUBAL CELL VOLTAGE ...

171

Superconducting Cable Construction and Testing  

Science Conference Proceedings (OSTI)

Superconducting cables, carrying three to five times more power than conventional cables, can meet increasing power demands in urban areas via retrofit applications. These high capacity cables will allow utilities to greatly enhance capacity, thereby giving the grid more flexibility and reliability. This report describes the development, construction, and testing of a superconducting cable system. Background In the late eighties, a new class of ceramic oxides was discovered with superconducting propertie...

2000-11-10T23:59:59.000Z

172

Pressurization Tests on High-Pressure Fluid-Filled Underground Transmission Cables of Public Service Electric & Gas Company  

Science Conference Proceedings (OSTI)

This report describes pressurization tests performed on 138-kV and 230-kV high-pressure fluid-filled (HPFF) transmission cable samples. The samples were removed from two Public Service Electric & Gas Company (PSE&G) underground transmission lines.

2009-12-10T23:59:59.000Z

173

High-voltage atmospheric breakdown across intervening rutile dielectrics.  

SciTech Connect

This report documents work conducted in FY13 on electrical discharge experiments performed to develop predictive computational models of the fundamental processes of surface breakdown in the vicinity of high-permittivity material interfaces. Further, experiments were conducted to determine if free carrier electrons could be excited into the conduction band thus lowering the effective breakdown voltage when UV photons (4.66 eV) from a high energy pulsed laser were incident on the rutile sample. This report documents the numerical approach, the experimental setup, and summarizes the data and simulations. Lastly, it describes the path forward and challenges that must be overcome in order to improve future experiments for characterizing the breakdown behavior for rutile.

Williamson, Kenneth Martin; Simpson, Sean; Coats, Rebecca Sue; Jorgenson, Roy Eberhardt; Hjalmarson, Harold Paul; Pasik, Michael Francis

2013-09-01T23:59:59.000Z

174

Project Fact Sheet Long Island HTS Power Cable Superconducting  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Long Long Island HTS Power Cable Superconducting Power Equipment www.oe.energy.gov Phone: 202-586-1411 Office of Electricity Delivery and Energy Reliability, OE-1 U.S. Department of Energy - 1000 Independence Avenue, SW - Washington, DC 20585 Plugging America Into the Future of Power What is the status of the Project? The cable was energized April 22, 2008 and serves the equivalent of 300,000 homes. It is the first HTS power cable to operate at transmission voltage in the grid. LIPA plans to retain the superconductor as a permanent part of it's grid. This project involves the demonstration of a high- temperature superconducting (HTS) power cable in the Long Island Power grid, spanning nearly half a mile and serving as a permanent link in the Long Island Power

175

A high-voltage low-power DC-DC buck regulator for automotive applications  

Science Conference Proceedings (OSTI)

This work presents a High-Voltage Low-Power CMOS DC-DC buck regulator for automotive applications. The overall system, including the high and low voltage analog devices, the power MOS and the low voltage digital devices, was realized in the Austriamicrosystems ... Keywords: DC-DC regulator, buck converter, current control, low quiscent current, pulse frequency modulation

G. Pasetti; L. Fanucci; R. Serventi

2010-03-01T23:59:59.000Z

176

CMOS flash analog-to-digital converter for high speed and low voltage applications  

Science Conference Proceedings (OSTI)

A CMOS flash analog-to-digital converter (ADC) designed for high speed and low voltage is presented. Using the Threshold Inverter Quantization (TIQ) comparator technique, a flash ADC can be applied to low supply voltage. A fat tree encoder that has signal ... Keywords: TIQ comparator, analog-to-digital converter, fat tree encoder, flash ADC, high speed, low voltage

Jincheol Yoo; Kyusun Choi; Jahan Ghaznavi

2003-04-01T23:59:59.000Z

177

Monolithic high voltage nonlinear transmission line fabrication process  

DOE Patents (OSTI)

A process for fabricating sequential inductors and varistor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varistor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process. 6 figs.

Cooper, G.A.

1994-10-04T23:59:59.000Z

178

Voltage spike detection in high field superconducting accelerator magnets  

SciTech Connect

A measurement system for the detection of small magnetic flux changes in superconducting magnets, which are due to either mechanical motion of the conductor or flux jump, has been developed at Fermilab. These flux changes are detected as small amplitude, short duration voltage spikes, which are {approx}15mV in magnitude and lasts for {approx}30 {micro}sec. The detection system combines an analog circuit for the signal conditioning of two coil segments and a fast data acquisition system for digitizing the results, performing threshold detection, and storing the resultant data. The design of the spike detection system along with the modeling results and noise analysis will be presented. Data from tests of high field Nb{sub 3}Sn magnets at currents up to {approx}20KA will also be shown.

Orris, D.F.; Carcagno, R.; Feher, S.; Makulski, A.; Pischalnikov, Y.M.; /Fermilab

2004-12-01T23:59:59.000Z

179

Monolithic high voltage nonlinear transmission line fabrication process  

DOE Patents (OSTI)

A process for fabricating sequential inductors and varactor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varactor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process.

Cooper, Gregory A. (346 Primrose Dr., Pleasant Hill, CA 94523)

1994-01-01T23:59:59.000Z

180

Circuit for monitoring temperature of high-voltage equipment  

DOE Patents (OSTI)

This invention relates to an improved circuit for measuring temperature in a region at high electric potential and generating a read-out of the same in a region at lower potential. The circuit is specially designed to combine high sensitivity, stability, and accuracy. A major portion of the circuit situated in the high-potential region can take the form of an integrated circuit. The preferred form of the circuit includes an input section which is situated in the high-potential region and comprises a temperature-compensated thermocouple circuit for sensing temperature, an oscillator circuit for generating a train of ramp voltages whose rise time varies inversely with the thermocouple output, a comparator and switching circuit for converting the oscillator output to pulses whose frequency is proportional to the thermocouple output, and a light-emitting diode which is energized by these pulses. An optical coupling transmits the light pulses generated by the diode to an output section of the circuit, situated in a region at ground. The output section comprises means for converting the transmitted pulses to electrical pulses of corresponding frequency, means for amplifying the electrical pulses, and means for displaying the frequency of the same. The preferred embodiment of the overall circuit is designed so that the frequency of the output signal in hertz and tenths of hertz is equal to the sensed temperature in degrees and tenths of degrees.

Jacobs, Martin E. (Chillicothe, OH)

1976-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Superconducting Power Cables  

Science Conference Proceedings (OSTI)

Power cables constructed from superconducting materials are being realized in utility demonstrations within the United States. Cooled by liquid nitrogen, high temperature superconducting power cables can transfer large amounts of power through relatively small cross sections. The key to their high power capacity is the high current density inherent with superconductors; a superconducting wire can conduct several times as much current as copper or aluminum conductors of the same cross section. For the pas...

2006-11-30T23:59:59.000Z

182

High-voltage supply for neutron tubes in well-logging applications  

DOE Patents (OSTI)

A high voltage supply is provided for a neutron tube used in well logging. The biased pulse supply of the invention combines DC and full pulse techniques and produces a target voltage comprising a substantial negative DC bias component on which is superimposed a pulse whose negative peak provides the desired negative voltage level for the neutron tube. The target voltage is preferably generated using voltage doubling techniques and employing a voltage source which generates bipolar pulse pairs having an amplitude corresponding to the DC bias level.

Humphreys, D.R.

1982-09-15T23:59:59.000Z

183

Ultra high-current superconducting cables for a 2. 2-Tesla, 300-kilojoule energy storage magnet  

DOE Green Energy (OSTI)

These 2.2-T, 300-kJ magnets are to operate at 10 to 12 kA with a safety factor in critical current of about 50 percent at 10 kA. The conductor must exhibit low losses in addition to being stable. Magnetic Corporation of America (MCA) designed a flat conductor using 1224 copper-matrix, monofilament wires combined in two stages of cabling followed by two stages of flat braiding. Two of these conductors were constructed, one with wire already on hand and the second using wire made specifically for this application. Intermagnetics General Corporation (IGC) designed two rectangular conductors using 315 and 319 mixed-matrix multifilament wires combined in three stages of cabling followed by compaction in a Turk's head. The maximum transport current capabilities (I/sub t/) of these cables were measured in hairpin shaped samples with the straight section under test in perpendicularly applied fields. The measured results at 2.5 T for the two MCA cables were 11.7 kA and 15.4 kA, and for the IGC cables were 18.2 kA and 19.3 kA (extrapolated). In addition, samples of the compacted and uncompacted major strands from the IGC cables were tested. The results of these measurements are compred with values of I/sub t/ from the single-wire critical currents taking into account the adjacent conductor fields and the cable self-fields.Several causes of degradation of I/sub t/ in the compacted cable are discussed including those due to experimental factors.

Miranda, G.A.; Rhodenizer, R.; Rackov, P.; Punchard, W.F.B.; de Winter, T.A.

1976-08-17T23:59:59.000Z

184

High voltage power supply with modular series resonant inverters  

DOE Patents (OSTI)

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360.degree./n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit.

Dreifuerst, Gary R. (Livermore, CA); Merritt, Bernard T. (Livermore, CA)

1995-01-01T23:59:59.000Z

185

High voltage power supply with modular series resonant inverters  

DOE Patents (OSTI)

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360{degree}/n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit. 11 figs.

Dreifuerst, G.R.; Merritt, B.T.

1995-07-18T23:59:59.000Z

186

ESS 2012 Peer Review - Low Cost, Manufacturable High Voltage...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Storage for Power Flow Management and Voltage Control on an 11kV UK Distribution Network", 20th International Conference on Electricity Distribution, June 2009. S1 S2 C1 C2...

187

High power impulse magnetron sputtering: Current-voltage-time ...  

pauses between pulses !typically 20 ms". The nominal volt-age of the pulser was adjustable up to 1000 V. The arc threshold was set to 120 A. If the current exceeded this

188

Reduce Nb3Sn Strand Deformation when Fabricating High Jc Rutherford Cables  

SciTech Connect

During Phase I, our efforts were to reduce subelements deformation when fabricating Nb3Sn Rutherford cables. Our first focus is on 217-sublement tube type strand. We successfully made a few billets in ���¾�¢��� OD tube with different Cu spacing between subelements, and supplied the strands to Fermi Lab for cabling. Through the rolling test characterization, these types of strands did not have enough bonding between subelements to withstand the deformation. We saw copper cracking between subelements in the deformed strands. We scaled up the billet from ���¾�¢��� OD to 1.5�¢��� OD, and made two billets. This greatly improves the bonding. There is no copper cracking in the deformed strands when we scaled up the diameter of the billets. Fermi Lab successfully made cables using one of this improved strands. In their cables, no Cu cracking and no filament bridging occurred. We also successfully made a couple of billets with hex OD and round ID subelements for 61-subelement restack. Due to the lack of bonding, we could not judge its cabling property properly. But we know through this experiment, we could keep the Nb round, once we select the proper Cu spacing.

Dr. Xuan Peng

2012-12-17T23:59:59.000Z

189

Theory and practice of dynamic voltage/frequency scaling in the high performance computing environment.  

E-Print Network (OSTI)

?? This dissertation provides a comprehensive overview of the theory and practice of Dynamic Voltage/Frequency Scaling (DVFS) in the High Performance Computing (HPC) environment. We… (more)

Rountree, Barry Louis

2010-01-01T23:59:59.000Z

190

Theory and Practice of Dynamic Voltage/Frequency Scaling in the High Performance Computing Environment .  

E-Print Network (OSTI)

??This dissertation provides a comprehensive overview of the theory and practice of Dynamic Voltage/Frequency Scaling (DVFS) in the High Performance Computing (HPC) environment. We summarize… (more)

Rountree, Barry

2009-01-01T23:59:59.000Z

191

Radio-Frequency Interference (RFI) From Extra-High- Voltage (EHV) Transmission Lines  

E-Print Network (OSTI)

The subject of radio-frequency interference (RFI) generated by high-voltage transmission lines has long been of both academic and commercial interest because of concerns about

Patrick C. Crane

2010-01-01T23:59:59.000Z

192

A model for the critical voltage for electrical degradation of GaN high electron mobility transistors  

E-Print Network (OSTI)

We have found that there is a critical drain-to-gate voltage beyond which GaN high-electron mobility transistors start to degrade in electrical-stress experiments. The critical voltage depends on the detailed voltage biasing ...

Joh, Jungwoo

193

Plant Engineering: Cable Aging Management Program Implementation Guidance  

Science Conference Proceedings (OSTI)

This report describes issues identified during the initial implementation of low- and medium-voltage cable aging management programs by utilities and presents possible resolutions and guidance.

2011-12-01T23:59:59.000Z

194

Failure Analysis of a 345 kV High-Pressure, Fluid-Filled Cable Insulated with Laminated Paper Polypropylene at New York Power Author ity  

Science Conference Proceedings (OSTI)

Three cable pieces of a 345-kV high-pressure, fluid-filled, laminated paper151polypropylene (LPP) cable, each nearly 3 ft in length, were received from New York Power Authority in January 2010. The Detroit Edison Company performed the dissection and analysis to address the cause(s) of the failure that occurred in late December 2009 and that was experienced by this 10.1 circuit-mile cable that had been energized in service in May 1991. One of the pieces contained the failure, and the other two were adjace...

2011-02-28T23:59:59.000Z

195

Superconductor cable  

Science Conference Proceedings (OSTI)

A superconductor cable includes a superconductive cable core (1) and a cryostat (2) enclosing the same. The cable core (1) has a superconductive conductor (3), an insulation (4) surrounding the same and a shielding (5) surrounding the insulation (4). A layer (3b) of a dielectric or semiconducting material is applied to a central element (3a) formed from a normally conducting material as a strand or tube and a layer (3c) of at least one wire or strip of superconductive material is placed helically on top. The central element (3a) and the layer (3c) are connected to each other in an electrically conducting manner at the ends of the cable core (1).

Allais, Arnaud (Hannover, DE); Schmidt, Frank (Langenhagen, DE

2009-12-15T23:59:59.000Z

196

Unlikely Combination of Experiments with a Novel High-Voltage CIGS Photovoltaic Array (Presentation)  

DOE Green Energy (OSTI)

The goals of this study are to: (1) parameterize current-voltage (I-V) performance over a wide range of illumination and temperatures: (a) 50-1150 W/m{sup 2} irradiance, 5-65 C; (b) obtain array temperature coefficients; and (c) quantify energy production; (2) investigate high-voltage leakage currents from the CIS modules in a high-voltage array: determine dependence on moisture, temperature, and voltage bias and ascertain corrosion problems if any; and (3) study long-term power and energy production stability.

del Cueto, J. A.; Sekulic, B. R.

2006-05-01T23:59:59.000Z

197

High voltage bus and auxiliary heater control system for an electric or hybrid vehicle  

DOE Green Energy (OSTI)

A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

Murty, Balarama Vempaty (West Bloomfield, MI)

2000-01-01T23:59:59.000Z

198

High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report | Open  

Open Energy Info (EERE)

High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report Jump to: navigation, search Tool Summary LAUNCH TOOL Name: High-Voltage Broadband-Over-Powerline (HV-BPL) Field Test Report Focus Area: Crosscutting Topics: Policy Impacts Website: www.netl.doe.gov/smartgrid/referenceshelf/reports/HV-BPL_Final_Report. Equivalent URI: cleanenergysolutions.org/content/high-voltage-broadband-over-powerline Language: English Policies: "Deployment Programs,Financial Incentives" is not in the list of possible values (Deployment Programs, Financial Incentives, Regulations) for this property. DeploymentPrograms: Technical Assistance This reports details findings from a pilot High Voltage Broadband over Power Line (HV-BPL) program, an effort to develop a disruptive technology

199

Capabilities of the High Voltage Stress Test System at the Outdoor Test Facility  

DOE Green Energy (OSTI)

We illustrate the capabilities of the High Voltage Stress Test (HVST) which operates continuously in the array field east of the Outdoor Test Facility at the National Renewable Energy Laboratory. Because we know that photovoltaic (PV) modules generating electrical power in both residential and utility-scale array installations will develop high-voltage biases approaching 600 VDC and 1,000 VDC, respectively, we expect such high voltages will result in current leakage between cells and ground, typically through the frames or mounts. We know that inevitably such leakage currents are capable of producing electrochemical corrosion that adversely impacts long-term module performance. With the HVST, we stress or operate PV modules under high-voltage bias, to characterize their leakage currents under all prevailing ambient conditions and assess performance changes emanating from high-voltage stress. We perform this test both on single modules and an active array.

del Cueto, J. A.; Trudell, D.; Sekulic, W.

2005-11-01T23:59:59.000Z

200

Assessment and Evaluation of Next Generation High-Voltage DC Technologies—Phase 2  

Science Conference Proceedings (OSTI)

As an established technology for bulk power transmission, high-voltage direct current (HVDC) power transmission is being used worldwide, and more than 100 schemes are operating at present. Advances in voltage sourced converter (VSC) technologies and power electronic devices with use of insulated-gate bipolar transistors (IGBTs) will provide improved system performance and reliability. Also, the present highest operating voltage is +/- 800 kV as China and India are building +/- 800-kV lines. Anticipating ...

2009-12-17T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

SECONDARY ELECTRON TRAJECTORIES IN HIGH-GRADIENT VACUUM INSULATORS WITH FAST HIGH-VOLTAGE PULSES  

Science Conference Proceedings (OSTI)

Vacuum insulators composed of alternating layers of metal and dielectric, known as high-gradient insulators (HGIs), have been shown to withstand higher electric fields than conventional insulators. Primary or secondary electrons (emitted from the insulator surface) can be deflected by magnetic fields from external sources, the high-current electron beam, the conduction current in the transmission line, or the displacement current in the insulator. These electrons are deflected either toward or away from the insulator surface and this affects the performance of the vacuum insulator. This paper shows the effects of displacement current from short voltage pulses on the performance of high gradient insulators. Generally, vacuum insulator failure is due to surface flashover, initiated by electrons emitted from a triple junction. These electrons strike the insulator surface thus producing secondary electrons, and can lead to a subsequent electron cascade along the surface. The displacement current in the insulator can deflect electrons either toward or away from the insulator surface, and affects the performance of the vacuum insulator when the insulator is subjected to a fast high-voltage pulse. Vacuum insulators composed of alternating layers of metal and dielectric, known as high-gradient insulators (HGIs), have been shown to withstand higher electric fields than conventional insulators. HGIs, being tolerant of the direct view of high-current electron and ion beams, and having desirable RF properties for accelerators, are a key enabling technology for the dielectric-wall accelerators (DWA) being developed at Lawrence Livermore National Laboratory (LLNL). Characteristically, insulator surface breakdown thresholds go up as the applied voltage pulse width decreases. To attain the highest accelerating gradient in the DWA, short accelerating voltage pulses are only applied locally, along the HGI accelerator tube, in sync with the charged particle bunch, and the effects of displacement current on trajectories of electrons emitted from HGI surface are particularly interesting. This paper presents simulated electron trajectories experiencing either constant or short-duration applied voltage pulses. Comparisons of these trajectories clearly indicate the importance of the voltage pulse shape, especially the rise time, in the flashover initiation process for HGIs.

Chen, Y; Blackfield, D; Nelson, S D; Poole, B

2010-04-21T23:59:59.000Z

202

Summary of transient high-voltage calculations for the FRX-C experiment  

Science Conference Proceedings (OSTI)

Calculations of the electrical circuit equations are performed over a wide range of parameters corresponding to the FRX-C field-reversed THETA-pinch experiment at Los Alamos. Without any plasma or external damping, serious voltage doubling and quadrupling of the main capacitor bank charge voltage are observed. These oscillating high voltages are found to be adequately suppressed by the strategic placement of external snubber circuitry. On the other hand, no doubling of the THETA-pinch preionization bank charge voltage is found. Calculations of the equations for the z-pinch preionization circuit are also performed.

Kewish, R.W. Jr.; Rej, D.J.

1982-06-01T23:59:59.000Z

203

Albany HTS Power Cable | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

development and demonstration of a high-temperature superconducting (HTS) cable in the power grid in Albany, New York, including first-of-a-kind applications of a cable splice...

204

Light-weight DC to very high voltage DC converter  

DOE Patents (OSTI)

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current.

Druce, Robert L. (Union City, CA); Kirbie, Hugh C. (Dublin, CA); Newton, Mark A. (Livermore, CA)

1998-01-01T23:59:59.000Z

205

Light-weight DC to very high voltage DC converter  

DOE Patents (OSTI)

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current. 1 fig.

Druce, R.L.; Kirbie, H.C.; Newton, M.A.

1998-06-30T23:59:59.000Z

206

Radio-frequency powered glow discharge device and method with high voltage interface  

DOE Patents (OSTI)

A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components. 11 figures.

Duckworth, D.C.; Marcus, R.K.; Donohue, D.L.; Lewis, T.A.

1994-06-28T23:59:59.000Z

207

Radio-frequency powered glow discharge device and method with high voltage interface  

DOE Patents (OSTI)

A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components.

Duckworth, Douglas C. (Knoxville, TN); Marcus, R. Kenneth (Clemson, SC); Donohue, David L. (Vienna, AT); Lewis, Trousdale A. (Oak Ridge, TN)

1994-01-01T23:59:59.000Z

208

Telecontrol of Ultra-High Voltage Electron Microscope over Global IPv6 Network  

Science Conference Proceedings (OSTI)

Osaka University has an Ultra-High VoltageElectron Microscope (UHVEM) which can provide highquality specimen images for worldwide researchers. Forusability improvements, we have worked on thetelecontrol of the UHVEM. In this paper, we would liketo introduce ...

Toyokazu Akiyama; Shinji Shimojo; Shojiro Nishio; Yoshinori Kitatsuji; Steven Peltier; Thomas Hutton; Fang-Pang Lin

2003-01-01T23:59:59.000Z

209

Piezoelectric based high voltage power simulator for implantation  

Science Conference Proceedings (OSTI)

It is based on resonant method that allows the piezoelectric transformer to generate a ... The device is small and with high power density and high efficiency

210

Cermet insert high voltage holdoff improvement for ceramic/metal vacuum devices  

DOE Patents (OSTI)

An improved metal-to-ceramic seal is provided wherein the ceramic body of the seal contains an integral region of cermet material in electrical contact with the metallic member, e.g., an electrode, of the seal. The seal is useful in high voltage vacuum devices, e.g., vacuum switches, and increases the high-voltage holdoff capabilities of such devices. A method of fabricating such seals is also provided.

Ierna, W.F.

1986-03-11T23:59:59.000Z

211

3430 IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, VOL. 61, NO. 8, OCTOBER 2012 Experimental Validation of High-Voltage-Ratio  

E-Print Network (OSTI)

Validation of High-Voltage-Ratio Low-Input-Current-Ripple Converters for Hybrid Fuel Cell Supercapacitor

Simões, Marcelo Godoy

212

High voltage bus and auxiliary heater control system for an electric or hybrid vehicle  

DOE Patents (OSTI)

A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

Murty, Balarama Vempaty (West Bloomfield, MI)

2000-01-01T23:59:59.000Z

213

Testing of XLPE Transmission Cable Terminations at Three Utilities: Southern California Edison, Public Service Company of Colorado, and PECO Energy Company  

Science Conference Proceedings (OSTI)

Detection of discharges at an early stage will increase the reliability of high-voltage cable systems. EPRI has sponsored partial discharge testing of 14 cross-linked polyethylene (XLPE) cable terminations at Southern California Edison, Public Service Company of Colorado, and PECO Energy Company. Three of the 14 terminations showed evidence of partial discharge activity. This report describes the testing procedures and results obtained from performing very high frequency partial discharge measurements.

1997-06-04T23:59:59.000Z

214

Superconductor cable  

DOE Patents (OSTI)

A superconducting cable comprising an in-situ-formed type II superconductor, e.g. Nb.sub.3 Sn, in association with a stabilizing conductor both in heat transfer relationship with at least one passage adapted to carry liquified gaseous refrigerant. The conductor and said at least one passage are enclosed by a sheath comprising an alloy consisting essentially of about 49% nickel, about 4% chromium, about 3% niobium, about 1.4% titanium, about 1% aluminum, balance essentially iron.

Smith, Jr., Darrell F. (Huntington, WV); Lake, Bill L. (Ona, WV); Ballinger, Ronald G. (Andover, MA)

1988-01-01T23:59:59.000Z

215

Operational Results of Pulse Shaping Techniques for the High Voltage Convertor Modulator  

Science Conference Proceedings (OSTI)

The High Voltage Converter Modulators (HVCMs) are used to power the RF klystrons used throughout the accelerator systems at Spallation Neutron Source (SNS). The output voltage of the HVCM has significant droop and ripple which, combined with low level RF (LLRF) system limitations, affect performance and efficiency of accelerator cavities. In conjunction with the progress in development of the new HVCM controller, different pulse modulation techniques were implemented and studied on the test modulator. This paper discusses the results of implementation of frequency modulation and phase modulation on output voltage. Operational data, including full average power operation, of test modulator is also discussed. Future plans for the new modulation scheme will be presented.

Patel, Gunjan P [ORNL; Anderson, David E [ORNL; Solley, Dennis J [ORNL; Wezensky, Mark W [ORNL

2012-01-01T23:59:59.000Z

216

High-voltage crowbar circuit with cascade-triggered series ignitrons  

DOE Patents (OSTI)

A series string of ignitrons for switching a large current at high voltage to ground. Switching is initiated by means of a negative trigger pulse applied to the cathode of the lowest voltage level ignitron next to ground to draw ground current through diodes in the ignitor circuit. The trigger pulse is applied thereby to the next higher ignitron cathode and sequentially to the remainder of the ignitrons in the string through diodes in respective ignitor circuits. Full line voltage is held off of nonconducting diodes and ignitrons by means of varistors.

Baker, William R. (Orinda, CA)

1980-01-01T23:59:59.000Z

217

High-voltage crowbar circuit with cascade-triggered series ignitrons  

DOE Patents (OSTI)

A series string of ignitrons for switching a large current at high voltage to ground. Switching is initiated by means of a negative trigger pulse applied to the cathode of the lowest voltage level ignitron next to ground to draw ground current through diodes in the ignitor circuit. The trigger pulse is applied thereby to the next higher ignitron cathode and sequentially to the remainder of the ignitrons in the string through diodes in respective ignitor circuits. Full line voltage is held off of nonconducting diodes and ignitrons by means of varistors. 1 fig.

Baker, W.R.

1980-11-04T23:59:59.000Z

218

GaAs series connected photovoltaic converters for high voltage capacitor charging applications  

DOE Green Energy (OSTI)

This report describes the design features of series connected photovoltaic arrays which will be required to charge capacitors to relatively high (400V) voltages in time periods on the order of 1 microsecond. The factors which determine the array voltage and the capacitor charge time are given. Individual element junction designs, along with an interconnect scheme, and a semiconductor process to realize them are presented. Finally, the input laser optical required to meet the requirements is determined.

Rose, B.H.

1997-09-01T23:59:59.000Z

219

High-voltage DC transmission: a power electronics workhorse  

Science Conference Proceedings (OSTI)

Thyristor-based HVDC converter technology is used for highly reliable power transfer across natural or national boundaries or between AC systems designed for different frequencies or incompatible frequency controls. The author discusses the benefits ...

N. G. Hingorani

1996-04-01T23:59:59.000Z

220

The progress and challenges of threshold voltage control of high-k/metal-gated devices for advanced technologies (Invited Paper)  

Science Conference Proceedings (OSTI)

This paper discusses recent progress in and challenges of threshold voltage control for advanced high-k/metal-gated (HKMG) devices. It presents the impact on threshold voltage (V"t) control of incorporating La and Al into HKMG devices. A dipole moment ... Keywords: CMOS, Capping layer, EOT, High-k, Metal gate, Threshold voltage control

Hsing-Huang Tseng; Paul Kirsch; C. S. Park; Gennadi Bersuker; Prashant Majhi; Muhammad Hussain; Raj Jammy

2009-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Capacitor discharge process for welding braided cable  

SciTech Connect

A capacitor discharge process for welding a braided cable formed from a plurality of individual cable strands to a solid metallic electrically conductive member comprises the steps of: (a) preparing the electrically conductive member for welding by bevelling one of its end portions while leaving an ignition projection extending outwardly from the apex of the bevel; (b) clamping the electrically conductive member in a cathode fixture; (c) connecting the electrically conductive member clamped in the cathode fixture to a capacitor bank capable of being charged to a preselected voltage value; (d) preparing the braided cable for welding by wrapping one of its end portions with a metallic sheet to form a retaining ring operable to maintain the individual strands of the braided cable in fixed position within the retaining ring; (e) clamping the braided cable and the retaining ring as a unit in an anode fixture so that the wrapped end portion of the braided cable faces the ignition projection of the electrically conductive member; and (f) moving the cathode fixture towards the anode fixture until the ignition projection of the electrically conductive member contacts the end portion of the braided cable thereby allowing the capacitor bank to discharge through the electrically conductive member and through the braided cable and causing the electrically conductive member to be welded to the braided cable via capacitor discharge action.

Wilson, Rick D. (Corvallis, OR)

1995-01-01T23:59:59.000Z

222

Thermo-Mechanical Performance of 230-345kV High Pressure Pipe Type Cable Systems: Selection of Full Size Test Rig  

Science Conference Proceedings (OSTI)

This is a front-end project to the wider experimental study of the thermo-mechanical performance of high-pressure fluid-filled (HPFF) transmission class cables in pipe systems. The project first reviews published work on the mechanisms of deterioration of HPFF cables due to thermo-mechanical bending activity (TMB). The principal mechanisms are the reduction in electrical strength caused by a) damage and opening of the outer electrostatic shield layers and b) the increase in the size of the fluid filled b...

2004-12-27T23:59:59.000Z

223

Experimental Results from Droop Compensation for the High Voltage Converter Modulators  

Science Conference Proceedings (OSTI)

The High Voltage Convertor Modulators are used to power the RF klystrons used throughout the linear accelerator at the Spallation Neutron Source. The output voltage of the modulator has significant voltage droop and ripple which, combined with low level RF system limitations, affect performance and stability of the accelerator cavities. In conjunction with the progress in the development of the new controller, different modulation techniques were implemented and studied on the test modulator. This paper discusses experimental results from implementation of different modulation schemes has on the modulator output voltage pulse. Thermal measurements were carried out to determine the effect of these modulations schemes on long term reliability of the modulator. Future plans are also discussed.

Patel, Gunjan P [ORNL; Anderson, David E [ORNL; Peplov, Vladimir V [ORNL; Saethre, Robert B [ORNL; Solley, Dennis J [ORNL; Wezensky, Mark W [ORNL

2013-01-01T23:59:59.000Z

224

Field Guide Updates for 2011: Volume 1 - Compressors for High-Voltage Circuit Breakers, Volume 2 - Lubrication of High-Voltage Circu it Breakers  

Science Conference Proceedings (OSTI)

High-voltage circuit breakers (HVCBs) perform essential protection and control functions on power transmission networks. Circuit breakers have multiple components that must operate in concert in order for the breaker to perform properly. If one component, such as the air or hydraulic system, does not operate correctly, the circuit breaker may misoperate or fail, possibly resulting in equipment damage or an outageboth expensive consequences. To help utilities prevent such undesirable events, this field gu...

2011-12-12T23:59:59.000Z

225

Dual design resistor for high voltage conditioning and transmission lines  

DOE Patents (OSTI)

A dual resistor for eliminating the requirement for two different value resistors. The dual resistor includes a conditioning resistor at a high resistance value and a run resistor at a low resistance value. The run resistor can travel inside the conditioning resistor. The run resistor is capable of being advanced by a drive assembly until an electrical path is completed through the run resistor thereby shorting out the conditioning resistor and allowing the lower resistance run resistor to take over as the current carrier.

Siggins, Timothy Lynn (Newport News, VA); Murray, Charles W. (Hayes, VA); Walker, Richard L. (Norfolk, VA)

2007-01-23T23:59:59.000Z

226

Connecting Renewables Directly to the Grid: Resilient Multi-Terminal HVDC Networks with High-Voltage High-Frequency Electronics  

SciTech Connect

GENI Project: GE is developing electricity transmission hardware that could connect distributed renewable energy sources, like wind farms, directly to the grid—eliminating the need to feed the energy generated through intermediate power conversion stations before they enter the grid. GE is using the advanced semiconductor material silicon carbide (SiC) to conduct electricity through its transmission hardware because SiC can operate at higher voltage levels than semiconductors made out of other materials. This high-voltage capability is important because electricity must be converted to high-voltage levels before it can be sent along the grid’s network of transmission lines. Power companies do this because less electricity is lost along the lines when the voltage is high.

None

2012-01-23T23:59:59.000Z

227

The design, construction, and operation of long-distance high-voltage electricity transmission technologies.  

SciTech Connect

This report focuses on transmission lines, which operate at voltages of 115 kV and higher. Currently, the highest voltage lines comprising the North American power grid are at 765 kV. The grid is the network of transmission lines that interconnect most large power plants on the North American continent. One transmission line at this high voltage was built near Chicago as part of the interconnection for three large nuclear power plants southwest of the city. Lines at this voltage also serve markets in New York and New England, also very high demand regions. The large power transfers along the West Coast are generally at 230 or 500 kV. Just as there are practical limits to centralization of power production, there are practical limits to increasing line voltage. As voltage increases, the height of the supporting towers, the size of the insulators, the distance between conductors on a tower, and even the width of the right-of-way (ROW) required increase. These design features safely isolate the electric power, which has an increasing tendency to arc to ground as the voltage (or electrical potential) increases. In addition, very high voltages (345 kV and above) are subject to corona losses. These losses are a result of ionization of the atmosphere, and can amount to several megawatts of wasted power. Furthermore, they are a local nuisance to radio transmission and can produce a noticeable hum. Centralized power production has advantages of economies of scale and special resource availability (for instance, hydro resources), but centralized power requires long-distance transfers of power both to reach customers and to provide interconnections for reliability. Long distances are most economically served at high voltages, which require large-scale equipment and impose a substantial footprint on the corridors through which power passes. The most visible components of the transmission system are the conductors that provide paths for the power and the towers that keep these conductors at a safe distance from each other and from the ground and the natural and built environment. Common elements that are generally less visible (or at least more easily overlooked) include the maintained ROW along the path of the towers, access roads needed for maintenance, and staging areas used for initial construction that may be restored after construction is complete. Also visible but less common elements along the corridor may include switching stations or substations, where lines of similar or different voltages meet to transfer power.

Molburg, J. C.; Kavicky, J. A.; Picel, K. C.

2008-03-03T23:59:59.000Z

228

CABLE AMPACITY DERATING  

SciTech Connect

The purpose and objective of this calculation is to determine the maximum ampacity of the cables in the underground duct bank for ensuring compliance with cable limits.

Y. Shane

1995-07-24T23:59:59.000Z

229

Unlikely Combination of Experiments With a Novel High-Voltage CIGS Photovoltaic Array: Preprint  

DOE Green Energy (OSTI)

A new high-voltage array comprising bipolar strings of copper indium gallium diselenide (CIGS) photovoltaic (PV) modules was inaugurated in 2005. It is equipped with a unique combination of tests, which likely have never before been deployed simultaneously within a single array: full current-voltage (I-V) traces, high-voltage leakage current measurements, and peak-power tracking or temporal stepped-bias profiling. The array nominally produces 1 kW power at 1 sun. The array's electrical characteristics are continuously monitored and controlled with a programmable electronic load interfaced to a data acquisition system (DAS), that also records solar and meteorological data. The modules are mounted with their frames electrically isolated from earth ground, in order to facilitate measurement of the leakage currents that arise between the high voltage bias developed in the series-connected cells and modules and their mounting frames. Because the DAS can perform stepped biasing of the array as a function of time, synchronous detection of the leakage current data with alternating bias is available. Leakage current data and their dependence on temperature and voltage are investigated. Array power data are analyzed across a wide range of varying illuminations and temperatures from the I-V traces. Array performance is also analyzed from an energy output perspective using peak-power tracking data.

del Cueto, J. A.; Sekulic, B. R.

2006-05-01T23:59:59.000Z

230

Plant Support Engineering: Aging Management Program Development Guidance for Instrument and Control Cable Systems for Nuclear Power Plants  

Science Conference Proceedings (OSTI)

This document provides guidance for developing and implementing a cable aging management program for low-voltage instrument and control cable circuits in nuclear power plants. Guidance is provided for identifying cables located in adverse localized environments and determining if those environments have caused significant cable circuit degradation.

2010-11-29T23:59:59.000Z

231

Effect of high solenoidal magnetic fields on breakdown voltages of high vacuum 805 MHz cavities  

DOE Green Energy (OSTI)

There is an on going international collaboration studying the feasibility and cost of building a muon collider or neutrino factory [1,2]. An important aspect of this study is the full understanding of ionization cooling of muons by many orders of magnitude for the collider case. An important muon ionization cooling experiment, MICE [3], has been proposed to demonstrate and validate the technology that could be used for cooling. Ionization cooling is accomplished by passing a high-emittance muon beam alternately through regions of low Z material, such as liquid hydrogen, and very high accelerating RF Cavities within a multi-Tesla solenoidal field. To determine the effect of very large solenoidal magnetic fields on the generation of dark current, x-rays and on the breakdown voltage gradients of vacuum RF cavities, a test facility has been established at Fermilab in Lab G. This facility consists of a 12 MW 805 MHz RF station and a large warm bore 5 T solenoidal superconducting magnet containing a pill box type cavity with thin removable window apertures. This system allows dark current and breakdown studies of different window configurations and materials. The results of this study will be presented. The study has shown that the peak achievable accelerating gradient is reduced by a factor greater than 2 when solenoidal field of greater than 2 T are applied to the cavity.

Moretti, A.; Bross, A.; Geer, S.; Qian, Z.; /Fermilab; Norem, J.; /Argonne; Li, D.; Zisman, M.; /LBL, Berkeley; Torun, Y.; /IIT, Chicago; Rimmer, R.; /Jefferson Lab; Errede,; /Illinois U., Urbana

2005-10-01T23:59:59.000Z

232

Cooperative frequency control with a multi-terminal high-voltage DC network  

Science Conference Proceedings (OSTI)

We consider frequency control in power systems made of several non-synchronous AC areas connected by a multi-terminal high-voltage direct current (HVDC) grid. We propose two HVDC control schemes to make the areas collectively react to power imbalances, ... Keywords: Decentralized control, Frequency control, HVDC systems, Power system control

Alain Sarlette; Jing Dai; Yannick Phulpin; Damien Ernst

2012-12-01T23:59:59.000Z

233

LPAT: An interactive simulation tool for assessing the lightning performance of Hellenic high voltage transmission lines  

Science Conference Proceedings (OSTI)

The paper presents the Lightning Performance Assessment Tool (LPAT), an interactive simulation tool which assesses the lightning performance of high voltage transmission lines. The LPAT design was based on a recently published methodology that has been ... Keywords: Lightning performance, Optical transient density, Overhead transmission lines, Simulation, Software tool, User interface

P. Karampelas; L. Ekonomou; S. Panetsos; G. E. Chatzarakis

2011-01-01T23:59:59.000Z

234

Instantaneous Rainfall Rate: Its Measurement and Its Influence on High-Voltage Transmission Lines  

Science Conference Proceedings (OSTI)

When a high-voltage transmission line is exposed to rain there is generally a small amount of corona activity at the surface of the conductors. This activity usually results in a power loss and the generation of audible and radio noise. While the ...

Harold Kirkham

1980-01-01T23:59:59.000Z

235

Magnetic lens apparatus for a low-voltage high-resolution electron microscope  

DOE Patents (OSTI)

A lens apparatus in which a beam of charged particles of low accelerating voltage is brought to a focus by a magnetic field, the lens being situated behind the target position. The lens comprises an electrically-conducting coil arranged around the axis of the beam and a magnetic pole piece extending along the axis of the beam at least within the space surrounded by the coil. The lens apparatus comprises the sole focusing lens for high-resolution imaging in a low-voltage scanning electron microscope.

Crewe, Albert V. (Palos Park, IL)

1996-01-01T23:59:59.000Z

236

A new VME based high voltage power supply for large experiments  

SciTech Connect

A new VME based high voltage power supply has been developed for the D{O} experiment at Fermilab. There are three types of supplies delivering up to {plus_minus}5.6 kV at 1.0 mA or +2.0 kV at 3.0 mA with a set accuracy of 1.5 V and extremely low voltage ripples. Complete computer control has allowed many special features to be developed for the supply, including user-defined control land monitor groups, variable ramp rates, and advanced histogram and graphic functions. 3 refs.

Ahn, S.C.; Angstadt, R.D.; Droege, T.F.; Johnson, M.E.; MacKinnon, B.A.; McNulty, S.E.; Shea, M.F.; Thompson, R.N.; Watson, M.M. [Fermi National Accelerator Lab., Batavia, IL (United States); Franzini, P. [Columbia Univ., New York, NY (United States); Jones, A.A. [Superconducting Super Collider Lab., Dallas, TX (United States); Lopez, M.L. [La Plata Univ. Nacional (Argentina); Wimpenny, S.J.; Yang, M.J. [California Univ., Riverside, CA (United States)

1991-11-01T23:59:59.000Z

237

A new VME based high voltage power supply for large experiments  

Science Conference Proceedings (OSTI)

A new VME based high voltage power supply has been developed for the D{O} experiment at Fermilab. There are three types of supplies delivering up to {plus minus}5.6 kV at 1.0 mA or +2.0 kV at 3.0 mA with a set accuracy of 1.5 V and extremely low voltage ripples. Complete computer control has allowed many special features to be developed for the supply, including user-defined control land monitor groups, variable ramp rates, and advanced histogram and graphic functions. 3 refs.

Ahn, S.C.; Angstadt, R.D.; Droege, T.F.; Johnson, M.E.; MacKinnon, B.A.; McNulty, S.E.; Shea, M.F.; Thompson, R.N.; Watson, M.M. (Fermi National Accelerator Lab., Batavia, IL (United States)); Franzini, P. (Columbia Univ., New York, NY (United States)); Jones, A.A. (Superconducting Super Collider Lab., Dallas, TX (United States)); Lopez, M.L. (La Plata Univ. Nacional (Argentina)); Wimpenny, S.J.; Yang, M.J

1991-11-01T23:59:59.000Z

238

Transient sheath overvoltages in armored power cables  

SciTech Connect

This paper is concerned with methods of limiting the build-up of transient voltages between sheath and armor in long armored power cables. Calculations by a frequency dependent cable model demonstrate that this voltage can be efficiently limited to an acceptable level by introducing sheath-armor bondings at regular intervals, or by using a semiconductive sheath-armor interlayer. The paper investigates the required minimum length between bondings, as well as the required conductivity of the sheath-armor interlayer if the use of bondings is to be avoided.

Gustavsen, B. [Norwegian Electric Power Research Inst., Trondheim (Norway)] [Norwegian Electric Power Research Inst., Trondheim (Norway); Sletbak, J. [Norwegian Inst. of Technology, Trondheim (Norway)] [Norwegian Inst. of Technology, Trondheim (Norway)

1996-07-01T23:59:59.000Z

239

Prediction of insulation degradation of distribution power cables based on chemical analysis and electrical measurements.  

E-Print Network (OSTI)

??This thesis deals with the prediction of medium voltage cable insulation condition. Different kinds of electrical measurements and chemical analyses are tested to find out… (more)

Hyvönen, Petri

2008-01-01T23:59:59.000Z

240

Assessment of Paper-Insulated Lead-Covered Cable Condition: Electrical, Chemical, and Metallurgical Condition  

Science Conference Proceedings (OSTI)

This report summarizes the investigation of electrical, chemical, and metallurgical tests used to evaluate the condition of paper-insulated lead-covered (PILC) medium-voltage cables.

2003-02-25T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

THE COST OF MAINTENANCE TRANSFER UNDER LOAD TAP OF THE TRANSFORMERS POWER OF EXTRA HIGH VOLTAGE THE ELETRONORTE.  

E-Print Network (OSTI)

??In this work a methodology for reduction of maintenance cost in the on-load tap changers (OLTC) of extra high voltage is proposed. The methodology is… (more)

RAIMUNDO NONATO ROSA FILHO

2005-01-01T23:59:59.000Z

242

A Study On High Voltage AC Power Transmission Line Electric And Magnetic Field Coupling With Nearby Metallic Pipelines.  

E-Print Network (OSTI)

??In the recent years, there has been a trend to run metallic pipelines carrying petroleum products and high voltage AC power lines parallel to each… (more)

Gupta, Abhishek

2006-01-01T23:59:59.000Z

243

Lightweight Superconducting Cables for use with High-Field Magnets and Military Applications  

The development of YBCO coated conductors has resulted in high critical current densities, but have been limited by the upper critical field of the superconductor. Achieving higher fields would require the use of high-temperature super conductors, but ...

244

High Transport Current 2G HTS Cables with Low AC Losses  

Science Conference Proceedings (OSTI)

... Materials Forensics, Three-dimensional Modeling and Fractal Characterization · Vortex Physics in Oxide and Pnictide High Temperature Superconductors.

245

Table 1. Design specifications of ultra-high speed PM motor. Supply voltage (V) 12  

E-Print Network (OSTI)

Analysis of Ultra-High Speed Permanent-Magnet Motor Masaru Kano, and Toshihiko Noguchi Department@vos.nagaokaut.ac.jp Abstract This paper describes a design of an ultra-high speed (UHS) permanent-magnet (PM) synchronous motor, a surface permanent-magnet (SPM) motor (150,000 r/min, 1.5 kW) fed by a low voltage battery (12 V

Fujimoto, Hiroshi

246

Design and Optimization of Low Voltage High Performance Dual Threshold CMOS Circuits  

E-Print Network (OSTI)

Reduction in leakage power has become an important concern in lowvoltage, lowpower and high performance applications. In this paper, we use dual threshold technique to reduce leakage power by assigning high threshold voltage to some transistors in non-critical paths, and using lowthreshold transistors in critical paths. In order to achieve the best leakage power saving under target performance constraints, an algorithm is presented for selecting and assigning an optimal high threshold voltage. A general standby leakage current model which has been veri#ed by HSPICE is used to estimate standby leakage power. Results show that dual threshold technique is good for power reduction during both standby and active modes. The standby leakage power savings for some ISCAS benchmarks can be more than 50#. 1 Introduction With the growing use of portable and wireless electronic systems, reduction in power consumption has become more and more importantintoday's VLSI circuit and system designs #1#, ...

Liqiong Wei; Zhanping Chen; Mark Johnson; Kaushik Roy; Vivek De

1998-01-01T23:59:59.000Z

247

Optical fiber imaging for high speed plasma motion diagnostics: Applied to low voltage circuit breakers  

Science Conference Proceedings (OSTI)

An integrated portable measurement system is described for the study of high speed and high temperature unsteady plasma flows such as those found in the vicinity of high current switching arcs. An array of optical fibers allows the formation of low spatial resolution images, with a maximum capture rate of 1x10{sup 6} images per second (1 MHz), with 8 bit intensity resolution. Novel software techniques are reported to allow imaging of the arc; and to measure arc trajectories. Results are presented on high current (2 kA) discharge events in a model test fixture and on the application to a commercial low voltage circuit breaker.

McBride, J. W. [School of Engineering Sciences, University of Southampton, Highfield, Southampton SO17 1BJ (United Kingdom); Balestrero, A.; Tribulato, G. [ABB SACE DIVISION, ABB S.p.A., Via Baioni, Bergamo 35 IT-24123 (Italy); Ghezzi, L. [ABB SACE DIVISION, ABB S.p.A., Viale dell'Industria, Vittuone (MI)18 IT-20010 (Italy); Cross, K. J. [Taicaan Ltd., 2 Venture Road, Southampton Science Park, Southampton, Hampshire SO16 7NP (United Kingdom)

2010-05-15T23:59:59.000Z

248

CRYOGENIC LIFETIME TESTS ON A COMMERCIAL EPOXY RESIN HIGH VOLTAGE BUSHING  

SciTech Connect

High-temperature superconducting (HTS) power devices operating in liquid nitrogen frequently require high-voltage bushings to carry the current leads from the superconducting windings to the room temperature grid connections. Oak Ridge National Laboratory is collaborating with Waukesha Electric Systems, SuperPower, and Southern California Edison to develop and demonstrate an HTS utility power transformer. Previous dielectric high voltage tests in support of this program have been carried out in test cryostats with commercial epoxy resin bushings from Electro Composites Inc. (ECI). Though the bushings performed well in these short-term tests, their long-term operation at high voltage in liquid nitrogen needs to be verified for use on the utility grid. Long-term tests are being carried out on a sample 28-kV-class ECI bushing. The bushing has a monolithic cast, cycloaliphatic resin body and is fire- and shatter-resistant. The test cryostat is located in an interlocked cage and is energized at 25 kVac around the clock. Liquid nitrogen (LN) is automatically refilled every 9.5 hours. Partial discharge, capacitance, and leakage resistance tests are periodically performed to check for deviations from factory values. At present, over 2400 hours have been accumulated with no changes in these parameters. The tests are scheduled to run for four to six months.

Schwenterly, S W [ORNL; Pleva, Ed [Waukesha Electric Systems, Waukesha, WI; Ha, Tam T [ORNL

2012-01-01T23:59:59.000Z

249

Corrosion-proofing armored power cables  

Science Conference Proceedings (OSTI)

A study of 89 power cables that were buried in soils containing a high salt content is discussed. The study was conducted to determine the corrosion behavior of armored power cables. It was found that an outer protective covering made of bitumin and cable strands does not protect the armor jacket sufficiently against soil corrosion. It is recommended, therefore, that steel armor protection be discontinued for the protection of power cable jackets and that the armor should not be connected to the jacket with copper wire in the couplers.

Munits, N.M.

1983-05-01T23:59:59.000Z

250

EPRI High-Voltage Direct Current (HVDC) Transmission Reference Book: Interim Report  

Science Conference Proceedings (OSTI)

The EPRI High-Voltage Direct Current (HVDC) Transmission Reference Book is a state-of-the-art guidebook that provides transmission companies with a comprehensive, single source of technical information and guidance for designing, building, operating, and extending the life of HVDC transmission systems. The book joins the landmark series of EPRI power delivery reference books. These comprehensive guidebookseach printed with a distinctive colored coverdocument and distill the knowledge and experience of th...

2011-12-30T23:59:59.000Z

251

Field Guide: Compressors for High-Voltage Circuit Breakers, Optimized for Electronic Viewing  

Science Conference Proceedings (OSTI)

High-voltage circuit breakers perform essential protection and control functions on power transmission networks. A circuit breaker that fails to operate within its design time period may cause serious damage and extended outages. Proper maintenance of compressors can help to ensure that breakers operate reliably and can prevent premature failures. This field guide, which has been optimized for use on electronic devices such as smart phones and tablets, is intended to help utility field personnel properly...

2011-11-09T23:59:59.000Z

252

Round-robin artificial contamination test on high voltage dc insulators  

Science Conference Proceedings (OSTI)

This paper summarizes the results of a worldwide round-robin test of high voltage dc (HVDC) insulators, which was carried out in six laboratories aiming at standardization of the method for artificial contamination tests on HVDC insulators. Flashover characteristics of three kinds of specimens were evaluated by the clean fog and the salt fog procedures. Sufficient information is now available to allow the preparation of provisional international specifications for artificial contamination testing of HVDC insulators.

Naito, K.; Schneider, H.M.

1995-07-01T23:59:59.000Z

253

Proceedings: High Voltage Current Transformers and Bushings: Failure Prediction and Prevention Symposium  

Science Conference Proceedings (OSTI)

EPRI-sponsored research has identified key parameters indicative of condition and impending failure of oil-filled, high-voltage current transformers (HVCTs) and bushings. These findings will assist utilities to improve the monitoring of HVCTs and bushings, and to develop mitigation techniques to reduce the risk of catastrophic transformer failure. These proceedings present the results of this research and the experiences of other researchers worldwide.

1999-12-01T23:59:59.000Z

254

Effect of Space Charge on Surface Insulation of High-Voltage Direct-Current Bushings  

Science Conference Proceedings (OSTI)

Operating data on bushings and post insulators for HVDC converter stations demonstrate that large-diameter insulators perform poorly when exposed to a combination of rain or fog and airborne contaminants. A technique that produces an intense space charge, resulting in corona at the high-voltage electrode of HVDC bushings, shows promise of improving flashover performance in some laboratory applications, but apparently has little effect under simulated service conditions.

1987-11-03T23:59:59.000Z

255

Field Guide: Lubrication of High-Voltage Circuit Breakers - 2013 Update  

Science Conference Proceedings (OSTI)

High-voltage circuit breakers (HVCBs) perform essential protection and control functions on power transmission networks. Circuit breaker mechanisms have multiple components that must operate in concert in order for the breaker to perform properly. If one component does not operate correctly, the circuit breaker may mis-operate or fail. A circuit breaker mis-operation may cause equipment damage and outages—both expensive consequences. Proper lubrication ...

2013-12-19T23:59:59.000Z

256

Apparatus for injecting high power laser light into a fiber optic cable  

DOE Patents (OSTI)

High intensity laser light is evenly injected into an optical fiber by the combination of a converging lens and a multisegment kinoform (binary optical element). The segments preferably have multi-order gratings on each which are aligned parallel to a radial line emanating from the center of the kinoform and pass through the center of the element. The grating in each segment causes circumferential (lateral) dispersion of the light, thereby avoiding detrimental concentration of light energy within the optical fiber.

Sweatt, William C. (Albuquerque, NM)

1997-01-01T23:59:59.000Z

257

Voltage stability limits for weak power systems with high wind penetration.  

E-Print Network (OSTI)

??Analysis of power system voltage stability has practical value in increasing wind penetration levels. As wind penetration levels increase in power systems, voltage stability challenges… (more)

Tamimi, Ala

2011-01-01T23:59:59.000Z

258

High Frequency Effects of Variable Frequency Drives (VFD) on Electrical Submersible Pump (ESP) Systems  

E-Print Network (OSTI)

Variable frequency drives (VFD) and subsea (umbilical) cables are frequently used in electrical submersible pump (ESP) systems for offshore platforms. There are two basic system configurations for ESP systems; VFD can be installed on the platform and the motor is connected to it through an umbilical cable, and VFD and the motor are installed closely and they are connected to the system through an umbilical cable. In this thesis, the pros and cons of each configuration are mentioned, but the focus is on the system with a VFD controlled motor through a long umbilical cable. A 36-pulse VFD is studied. Since multilevel VFDs have high frequency harmonics, high frequency modeling of the umbilical cable is used, and skin effect is also taken into consideration in the cable. The effect of the interactions between the umbilical cable and high frequency harmonics on the motor terminal voltage is explored.

Ozkentli, Esra

2012-08-01T23:59:59.000Z

259

Development of an Oil Deterioration Test Method to Monitor the Condition of High-Pressure Fluid-Filled Paper Cable  

Science Conference Proceedings (OSTI)

Using a dissolved-gas analysis (DGA) service for "fingerprinting" as well as periodic analyses of HPFF cable can alert a utility to potential catastrophic events and to thermal or electrical changes in the insulating fluid. If accurate historical records are kept and updated, regular DGA can serve as a preventive and predictive maintenance test and possibly an indicator of remaining service life.

1991-12-01T23:59:59.000Z

260

Experimental Estimate of Beam Loading and Minimum rf Voltage for Acceleration of High Intensity Beam in the Fermilab Booster  

E-Print Network (OSTI)

The difference between the rf voltage seen by the beam and the accelerating voltage required to match the rate of change of the Booster magnetic field is used to estimate the energy loss per beam turn. Because the rf voltage (RFSUM) and the synchronous phase can be experimentally measured, they can be used to calculate the effective accelerating voltage. Also an RFSUM reduction technique has been applied to measure experimentally the RFSUM limit at which the beam loss starts. With information on beam energy loss, the running conditions, especially for the high intensity beam, can be optimized in order to achieve a higher intensity beam from the Fermilab Booster.

Yang, X; Norem, J; Yang, Xi

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Experimental estimate of beam loading and minimum rf voltage for acceleration of high intensity beam in the Fermilab Booster  

SciTech Connect

The difference between the rf voltage seen by the beam and the accelerating voltage required to match the rate of change of the Booster magnetic field is used to estimate the energy loss per beam turn. Because the rf voltage (RFSUM) and the synchronous phase can be experimentally measured, they can be used to calculate the effective accelerating voltage. Also an RFSUM reduction technique has been applied to measure experimentally the RFSUM limit at which the beam loss starts. With information on beam energy loss, the running conditions, especially for the high intensity beam, can be optimized in order to achieve a higher intensity beam from the Fermilab Booster.

Xi Yang; Charles M Ankenbrandt and Jim Norem

2004-04-01T23:59:59.000Z

262

A high voltage pulsed power supply for capillary discharge waveguide applications  

Science Conference Proceedings (OSTI)

We present an all solid-state, high voltage pulsed power supply for inducing stable plasma formation (density {approx}10{sup 18} cm{sup -3}) in gas-filled capillary discharge waveguides. The pulser (pulse duration of 1 {mu}s) is based on transistor switching and wound transmission line transformer technology. For a capillary of length 40 mm and diameter 265 {mu}m and gas backing pressure of 100 mbar, a fast voltage pulse risetime of 95 ns initiates breakdown at 13 kV along the capillary. A peak current of {approx}280 A indicates near complete ionization, and the r.m.s. temporal jitter in the current pulse is only 4 ns. Temporally stable plasma formation is crucial for deploying capillary waveguides as plasma channels in laser-plasma interaction experiments, such as the laser wakefield accelerator.

Abuazoum, S.; Wiggins, S. M.; Issac, R. C.; Welsh, G. H.; Vieux, G.; Jaroszynski, D. A. [Department of Physics, Scottish Universities Physics Alliance, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Ganciu, M. [Low Temperature Plasma Department, National Institute of Lasers, Plasma and Radiation Physics, 077125, Magurele, Bucharest (Romania)

2011-06-15T23:59:59.000Z

263

High Voltage CMOS Control Interface for Astronomy - Grade Charged Coupled Devices  

E-Print Network (OSTI)

The Pan-STARRS telescope consists of an array of smaller mirrors viewed by a Gigapixel arrays of CCDs. These focal planes employ Orthogonal Transfer CCDs (OTCCDs) to allow on-chip image stabilization. Each OTCCD has advanced logic features that are controlled externally. A CMOS Interface Device for High Voltage has been developed to provide the appropiate voltage signal levels from a readout and control system designated STARGRASP. OTCCD chip output levels range from -3.3V to 16.7V, with two different output drive strenghts required depending on load capacitance (50pF and 1000pF), with 24mA of drive and a rise time on the order of 100ns. Additional testing ADC structures have been included in this chip to evaluate future functional additions for a next version of the chip.

Martin, Elena; Koga, Aaron; Ruckman, Larry; Onaka, Peter; Tonry, John; Lee, Aaron

2008-01-01T23:59:59.000Z

264

Feasibility of high-voltage systems for a very long drift in liquid argon TPCs  

E-Print Network (OSTI)

Designs of high-voltage (HV) systems for creating a drift electric field in liquid argon TPCs are reviewed. In ongoing experiments systems capable of approx. 100 kV are realised for a drift field of 0.5-1 kV/cm over a length of up to 1.5 m. Two of them having different approaches are presented: (1) the ICARUS-T600 detector having a system consisting of an external power supply, HV feedthroughs and resistive voltage degraders and (2) the ArDM-1t detector having a cryogenic Greinacher HV multiplier inside the liquid argon volume. For a giant scale liquid argon TPC, a system providing 2 MV may be required to attain a drift length of approx. 20 m. Feasibility of such a system is evaluated by extrapolating the existing designs.

Horikawa, S; Kaufmann, L; Laffranchi, M; Marchionni, A; Messina, M; Natterer, G; Rubbia, A

2010-01-01T23:59:59.000Z

265

Electrochemical Windows of Sulfone-Based Electrolytes for High-Voltage Li-Ion Batteries  

Science Conference Proceedings (OSTI)

Further development of high-voltage lithium-ion batteries requires electrolytes with electrochemical windows greater than 5 V. Sulfone-based electrolytes are promising for such a purpose. Here we compute the electrochemical windows for experimentally tested sulfone electrolytes by different levels of theory in combination with various solvation models. The MP2 method combined with the polarizable continuum model is shown to be the most accurate method to predict oxidation potentials of sulfone-based electrolytes with mean deviation less than 0.29 V. Mulliken charge analysis shows that the oxidation happens on the sulfone group for ethylmethyl sulfone and tetramethylene sulfone, and on the ether group for ether functionalized sulfones. Large electrochemical windows of sulfone-based electrolytes are mainly contributed by the sulfone group in the molecules which helps lower the HOMO level. This study can help understand the voltage limits imposed by the sulfone-based electrolytes and aid in designing new electrolytes with greater electrochemical windows.

Shao, Nan [ORNL; Sun, Xiao-Guang [ORNL; Dai, Sheng [ORNL; Jiang, Deen [ORNL

2011-01-01T23:59:59.000Z

266

Electric power high-voltage transmission lines: Design options, cost, and electric and magnetic field levels  

SciTech Connect

This report provides background information about (1) the electric and magnetic fields (EMFs) of high-voltage transmission lines at typical voltages and line configurations and (2) typical transmission line costs to assist on alternatives in environmental documents. EMF strengths at 0 {+-} 200 ft from centerline were calculated for ac overhead lines, and for 345 and 230-kV ac underground line and for a {+-}450-kV dc overhead line. Compacting and height sensitivity factors were computed for the variation in EMFs when line conductors are moved closer or raised. Estimated costs for the lines are presented and discussed so that the impact of using alternative strategies for reducing EMF strengths and the implications of implementing the strategies can be better appreciated.

Stoffel, J.B.; Pentecost, E.D.; Roman, R.D.; Traczyk, P.A.

1994-11-01T23:59:59.000Z

267

Novel Nonflammable Electrolytes for Secondary Magnesium Batteries and High Voltage Electrolytes for Electrochemcial Supercapacitors  

Science Conference Proceedings (OSTI)

Magnesium has been used successfully in primary batteries, but its use in rechargeable cells has been stymied by the lack of suitable non-aqueous electrolyte that can conduct Mg+2 species, combined with poor stripping and plating properties. The development of a suitable cathode material for rechargeable magnesium batteries has also been a roadblock, but a nonflammable electrolyte is key. Likewise, the development of safe high voltage electrochemical supercapaitors has been stymied by the use of flammable solvents in the liquid electrolyte; to wit, acetonitrile. The purpose of the research conducted in this effort was to identify useful compositions of magnesium salts and polyphosphate solvents that would enable magnesium ions to be cycled within a secondary battery design. The polyphosphate solvents would provide the solvent for the magnesium salts while preventing the electrolyte from being flammable. This would enable these novel electrolytes to be considered as an alternative to THF-based electrolytes. In addition, we explored several of these solvents together with lithium slats for use as high voltage electrolytes for carbon-based electrochemical supercapacitors. The research was successful in that: 1) Magnesium imide dissolved in a phosphate ester solvent that contains a halogented phosphate ester appears to be the preferred electrolyte for a rechargeable Mg cell. 2) A combination of B-doped CNTs and vanadium phosphate appear to be the cathode of choice for a rechargeable Mg cell by virtue of higher voltage and better reversibility. 3) Magnesium alloys appear to perform better than pure magnesium when used in combination with the novel polyphosphate electrolytes. Also, this effort has established that Phoenix Innovationâ??s family of phosphonate/phosphate electrolytes together with specific lithium slats can be used in supercapacitor systems at voltages of greater than 10V.

Dr. Brian Dixon

2008-12-30T23:59:59.000Z

268

Cost Reduction Activities in France for Installing Cable: Mechanical Laying Techniques  

Science Conference Proceedings (OSTI)

In the past few decades, there has been increasing public objection to the undesirable visual impact of overhead power lines. Utilities face difficulties in obtaining authorization to build new overhead lines. This situation has led to the power industry's current interest in underground cable techniques. Buried insulated cable faces two difficulties, technical and economic, both depending on the level of voltage. At medium voltage (essentially 20 kilovolts), the optimization of cable systems, combined w...

2001-01-03T23:59:59.000Z

269

Subject: Results of Test 5 on Bonded Jacket Electric Cables Dear Satish:  

E-Print Network (OSTI)

As you know, we have recently completed the fifth test in our research program on low-voltage electric cables (JCN W-6465). The objective of this test was to determine if bonded jacket cables have any unique failure mechanisms that are not present in unbondedjacket cables. To achieve this objective, EPR insulated cables with both a bonded and unbonded CSPE jacket were preaged and accident tested. The cables were manufactured by Okonite, Samuel Moore, and Anaconda. As a result of this test, one of the two Okonite cables preaged to simulate 20 years of qualified life, and three of the three Okonite cables preaged to simulate 40 years of qualified life failed catastrophically by splitting open. These results call into question the qualification basis for these cables. The Samuel Moore and Anaconda cables performed acceptably. The enclosed letter report documents the findings of this test. If you have any questions on this, please contact me. Sincerely,

Mr. Satish; K. Aggarwal; Robert J. Lofaro; S. Carfagno; E. Grove

2000-01-01T23:59:59.000Z

270

Degradation of Photovoltaic Modules Under High Voltage Stress in the Field: Preprint  

DOE Green Energy (OSTI)

The degradation in performance for eight photovoltaic (PV) modules stressed at high voltage (HV) is presented. Four types of modules--tandem-junction and triple-junction amorphous thin-film silicon, plus crystalline and polycrystalline silicon modules--were tested, with a pair of each biased at opposite polarities. They were deployed outdoors between 2001 and 2009 with their respective HV leakage currents through the module encapsulation continuously monitored with a data acquisition system, along with air temperature and relative humidity. For the first 5 years, all modules were biased continuously at fixed 600 VDC, day and night. In the last 2 years, the modules were step-bias stressed cyclically up and down in voltage between 10 and 600 VDC, in steps of tens to hundreds of volts. This allowed characterization of leakage current versus voltage under a large range of temperature and moisture conditions, facilitating determination of leakage paths. An analysis of the degradation is presented, along with integrated leakage charge. In HV operation: the bulk silicon modules degraded either insignificantly or at rates of 0.1%/yr higher than modules not biased at HV; for the thin-film silicon modules, the added loss rates are insignificant for one type, or 0.2%/yr-0.6%/yr larger for the other type.

del Cueto, J. A.; Rummel, S. R.

2010-08-01T23:59:59.000Z

271

Electronically controlled cable wrapper  

DOE Patents (OSTI)

A spindle assembly engages and moves along a length of cable to be wrapped with insulating tape. Reels of insulating tape are mounted on a outer rotatable spindle which revolves around the cable to dispense insulating tape. The rate of movement of the spindle assembly along the length of the cable is controlled by a stepper motor which is programmably synchronized to the rate at which rotatable spindle wraps the cable. The stepper motor drives a roller which engages the cable and moves the spindle assembly along the length of the cable as it is being wrapped. The spindle assembly is mounted at the end of an articulated arm which allows free movement of the spindle assembly and allows the spindle assembly to follow lateral movement of the cable.

Young, T.M.

1982-08-17T23:59:59.000Z

272

A Fusing Switch for Fault Suppression in the SNS High Voltage Converter Modulators  

DOE Green Energy (OSTI)

The High Voltage Converter Modulators (HVCMs) at the Spallation Neutron Source (SNS) have operated in excess of a combined 250,000 hours. Performance and reliability improvements to the HVCM are ongoing to increase modulator availability as accelerator system demands increase. There is a relatively large amount of energy storage in the HVCMs, {approx}180 kJ. This energy has the potential to dump into unsuppressed faults, cause damage, and increase the time to repair. The 'fusing switch' concept involves isolation of this stored energy from the location of the most common faults. This paper introduces this concept and its application to the HVCMs.

Kemp, Mark A.; Burkhart, Craig; Nguyen, Minh N.; /SLAC; Anderson, David E.; /Oak Ridge

2009-08-03T23:59:59.000Z

273

Definition: Very Low Impedance (Hts) Cables | Open Energy Information  

Open Energy Info (EERE)

Very Low Impedance (Hts) Cables Very Low Impedance (Hts) Cables Jump to: navigation, search Dictionary.png Very Low Impedance (Hts) Cables Cables that use conducting materials that are very low impedance, which can enable better power flow control. Cables that use high temperature superconducting (HTS) conductor would be characterized as a VLI cable. HTS cables may enable additional benefits such as lower losses, increased power density, and self-fault limiting.[1] Related Terms power, power flow control References ↑ [www.smartgrid.gov/sites/default/files/pdfs/description_of_assets.pdf SmartGrid.gov 'Description of Assets'] An i LikeLike UnlikeLike You like this.Sign Up to see what your friends like. nline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Very_Low_Impedance_(Hts)_Cables&oldid=480440

274

Market Manual (Draft rev 5 – ‘Clean’) Transmission Grid- High Voltage Metering  

E-Print Network (OSTI)

1.1. The Market Rules allow metering installations to be placed on the high voltage (HV) grid on the supply side of the Defined Meter Point. 1.2. The Market Rules allow metering installations on the high voltage grid to be associated to more than one connection point or embedded connection point. 1.3. The Market Rules permit a metering installation to be registered in respect of more than one facility even though the meter point is not located at the defined meter points, provided that all transfers of energy at any points of supply or consumption for the facilities to which the metering installation relates are determined in a manner satisfactory to the IESO. 1.4. This arrangement permits a reduction in the number of metering installations by using a single HV metering installation to settle multiple connection points or embedded connection points to a single delivery point. This arrangement applies to both energy and transmission settlement. 1.5. Any adjustment between the metering installations and the normal location of the Delivery Point(s) may be by means of an adjustment formula, provided that all

unknown authors

2008-01-01T23:59:59.000Z

275

Superconducting Power Cables  

Science Conference Proceedings (OSTI)

This report is a continuation of a Technology Watch series on superconducting power cables that summarize full-scale superconducting cable projects throughout the world ranging from full-scale test installations to utility demonstration projects. The report covers various aspects of each project from design to implementation. When available, updated status regarding operation and maintenance (O&M) also is presented. The report will serve as a knowledge resource on the status of superconducting cable tech...

2008-12-19T23:59:59.000Z

276

Sulfone-based electrolytes for high voltage li-ion batteries.  

Science Conference Proceedings (OSTI)

Sulfone-based electrolytes have been investigated as electrolytes for lithium-ion cells using high-voltage positive electrodes, such as LiMn{sub 2}O{sub 4} and LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} spinels, and Li{sub 4}Ti{sub 5}O{sub 12} spinel as negative electrode. In the presence of imide salt (LiTFSI) and ethyl methyl sulfone or tetramethyl sulfone (TMS) electrolytes, the Li{sub 4}Ti{sub 5}O{sub 12}/LiMn{sub 2}O{sub 4} cell exhibited a specific capacity of 80 mAh g{sup -1} with an excellent capacity retention after 100 cycles. In a cell with high-voltage LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} positive electrode and 1 M LiPF{sub 6} in TMS as electrolyte, the capacity reached 110 mAh g{sup -1} at the C/12 rate. When TMS was blended with ethyl methyl carbonate, the Li{sub 4}Ti{sub 5}O{sub 12}/LiNi{sub 0.5}Mn{sub 1.5}O{sub 4} cell delivered an initial capacity of 80 mAh g{sup -1} and cycled fairly well for 1000 cycles under 2C rate. The exceptional electrochemical stability of the sulfone electrolytes and their compatibility with the Li{sub 4}Ti{sub 5}O{sub 12} safer and stable anode were the main reason behind the outstanding electrochemical performance observed with high-potential spinel cathode materials. These electrolytes could be promising alternative electrolytes for high-energy density battery applications such as plug-in hybrid and electric vehicles that require a long cycle life.

Abouimrane, A.; Belharouak, I.; Amine, K. (Chemical Sciences and Engineering Division)

2009-05-01T23:59:59.000Z

277

High Temperature Superconductivity -- A Joint Feasibility Study for a Power Application with High-Temperature Superconducting Cable by Peco Energy  

Science Conference Proceedings (OSTI)

Practical realization of high temperature superconductivity (HTS) technology is within the electric power industry's reach. This report documents a feasibility study co-sponsored by PECO Energy Company (PECO) to assess a real-world underground transmission application of this technology.

1998-11-17T23:59:59.000Z

278

High Temperature Superconductivity -- A Joint Feasibility Study for a Power Application with High-Temperature Superconducting Cable by South Carolina  

Science Conference Proceedings (OSTI)

Practical realization of high temperature superconductivity (HTS) technology is within the reach of the electric power industry. This report documents a feasibility study co-sponsored by South Carolina Electric and Gas Company (SCE&G) to assess a real-world underground transmission application of this technology.

1998-11-17T23:59:59.000Z

279

EPRI High-Voltage Direct Current (HVDC) Reference Book: Chapter 24 - Operation and Maintenance of HVDC Systems  

Science Conference Proceedings (OSTI)

This report contains descriptions of the operation and maintenance (O&M) activities of traditional high-voltage direct current (HVDC) line commutated (thyristor-based) and voltage-sourced converter (VSC) transmission systems. Both long-distance transmission schemesincluding the transmission linesand back-to-back schemes are included. The various tasks involved in the O&M of HVDC systems are described at some length, and a range of estimates is given for the staff requirements to carry out these activitie...

2010-01-19T23:59:59.000Z

280

High Voltage MOSFET Gate/Bulk Driver Controller for a Microbattery Switch Matrix in a 0.35 µm Microwave SOI Technology  

Science Conference Proceedings (OSTI)

Integrated microbatteries are being currently developed to act as a "micropower" source in microsatellites. The current and voltage rating of the microbattery is fixed. Certain highly miniaturized systems require higher voltages and currents. A switching ... Keywords: LDMOSFET, SOI, microbattery, micropower

Vinesh Sukumar; Mahmoud Alahmad; Kevin Buck; Herbert Hess; Harry Li; Dave Cox; Fadi Nessir Zghoul; Jeremy Jackson; Stephen Terry; Ben Blalock; M. M. Mojarradi; W. C. West; J. F. Whitacre

2005-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

ESS 2012 Peer Review - Low Cost, Manufacturable High Voltage Power Module for ESS - Brandon Passmore, APEI  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

W. Research Center Blvd. * Fayetteville, AR 72701 * (479) 443-5759 W. Research Center Blvd. * Fayetteville, AR 72701 * (479) 443-5759 Design and Development of a Low Cost, Manufacturable High Voltage Power Module for Energy Storage Systems Phase I SBIR September 27, 2012 Brandon Passmore, PhD Sr. Electronics Packaging Research Engineer Email: bpassmo@apei.net Acknowledgements * I would like to thank Dr. Imre Gyuk of the DOE Energy Storage Systems Program and Dr. Stan Atcitty for technical support * I would also like to thank 2 Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

282

Artificial SEI Enables High-Voltage Lithium-ion Batteries | ornl.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Functional Materials for Energy Functional Materials for Energy Artificial SEI Enables High-Voltage Lithium-ion Batteries September 03, 2013 Efficacy of Lipon coating as an artificial SEI for suppression of electrolyte decomposition on a 5V spinel cathode: coulombic efficiency was measured versus cycle numbers at samples with different coating thickness. An artificial solid electrolyte interphase (SEI) of lithium phosphorus oxynitride (Lipon) enables the use of 5V cathode materials with conventional carbonate electrolytes in lithium-ion batteries. Five volt cathode materials, such as LiNi0.5Mn1.5O4, are desirable to provide higher energy, however conventional carbonate electrolytes decompose above 4.5V compromising the battery performance. This work shows that Lipon coating suppresses the electrolyte decomposition, as measured by the

283

ANUEADflM-31 Electric Power High-Voltage Transmission Lines:  

Office of Scientific and Technical Information (OSTI)

ANUEADflM-31 ANUEADflM-31 Electric Power High-Voltage Transmission Lines: Design Options, Cost, and Electric and Magnetic Field Levels by J.B. Stoffel,' E.D. Pentecost, R.D. Roman, and P.A. Traczyk Environmental Assessment Division, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 November 1994 Work sponsored by United States Department of Energy, Assistant Secretary for Fossil Energy, Office of Fuels Program Stoffel is affiliated with Argonne's Electronics and Computing Technologies Division. D4SlRlBUTlON OF THIS DOCUMENT IS UNLiMltEb - . - . - . - . ... - , . ^ ~ .. , . . . , . . _ I T h i s report i s printed on recycled paper. @ . . .. . ' . . . A :_ - .. ., . . DISCLAIMER This report was .prepared as an account of work sponsored by an agency of the United States Government. Neither

284

Status of High Polarization DC High Voltage GaAs Photoguns  

SciTech Connect

This talk will review the state of the art of high polarization GaAs photoguns used worldwide. Subject matter will include drive laser technology, photocathode material, gun design, vacuum requirements and photocathode lifetime as a function of beam current. Recent results have demonstrated high current, 85% polarized beams with high reliability and long lifetime under operational conditions. Research initiatives for ensuring production of high average and peak current beams for future accelerator facilities such as ELIC and the ILC will be also discussed.

P. A. Adderley; J. Brittian; J. Clark; J. Grames; J. Hansknecht; J. McCarter; M. Poelker; M. L. Stutzman; R. Suleiman; K. E. L. Surles-Law

2007-08-01T23:59:59.000Z

285

Distribution Class Nanodielectric Cable: Status Report and Future Prospects  

Science Conference Proceedings (OSTI)

The Electric Power Research Institute (EPRI) has been pursuing the development of a nanocomposite cable insulation compound for several years. Early successes in the laboratory led to commercialization efforts with Dow Chemical Company and several trial runs of commercial-scale compound manufacturing. Medium-voltage underground cables were made with the experimental compound. The fundamental challenge in dispersing nanoscale particles into a bulk polymer is achieving a homogenous dispersion throughout t...

2011-12-18T23:59:59.000Z

286

Multistrand superconductor cable  

DOE Patents (OSTI)

Improved multistrand Rutherford-type superconductor cable is produced by using strands which are preformed, prior to being wound into the cable, so that each strand has a variable cross section, with successive portions having a substantially round cross section, a transitional oval cross section, a rectangular cross section, a transitional oval cross section, a round cross section and so forth, in repetitive cycles along the length of the strand. The cable is wound and flattened so that the portions of rectangular cross section extend across the two flat sides of the cable at the strand angle. The portions of round cross section are bent at the edges of the flattened cable, so as to extend between the two flat sides. The rectangular portions of the strands slide easil

Borden, A.R.

1984-03-08T23:59:59.000Z

287

PRESENT AND FUTURE TECHNOLOGY OF HIGH VOLTAGE SYSTEMS FOR NEUTRAL BEAM INJECTORS  

E-Print Network (OSTI)

the accel voltage reg­ ulation requirement could be relaxedVOLTAGE SWITCHES TUBES SCR ASSEMBLIES CROSSED-FIELD INTERRUPTERS MAGNETIC CORE ARC SNUEBER3 COMPUTERS FOR CONTROL AND DIAGNOSTICS OPERATIONAL REQUIREMENTSvoltage- regulated (flat-topped) to 1%. If good regulation Is not a prime requirement,

Baker, W.R.

2011-01-01T23:59:59.000Z

288

Transmission Cable Life Evaluation and Management  

Science Conference Proceedings (OSTI)

High-pressure fluid-filled (HPFF) transmission cable systems constitute nearly 80 percent of the transmission cables in the United States, and represent an estimated $18 billion investment, in present-day dollars. Many of these systems are reaching or have exceeded their design life of 40 years, and evaluating their condition and remaining life is of utmost importance to utilities seeking to make full use of their underground transmission assets. This report describes procedures and diagnostic tools for ...

1998-12-24T23:59:59.000Z

289

An Ultra-Compact Marx-Type High-Voltage Generator  

DOE Green Energy (OSTI)

This paper discusses the design of an ultra-compact, Marx-type, high-voltage generator. This system incorporates high-performance components that are closely coupled and integrated into an extremely compact assembly. Low profile, custom ceramic capacitors with coplanar extended electrodes provide primary energy storage. Low-inductance, spark-gap switches incorporate miniature gas cavities imbedded within the central region of the annular shaped capacitors, with very thin dielectric sections separating the energy storage capacitors. Carefully shaped electrodes and insulator surfaces are used throughout to minimize field enhancements, reduce fields at triple-point regions, and enable operation at stress levels closer to the intrinsic breakdown limits of the dielectric materials. Specially shaped resistors and inductors are used for charging and isolation during operation. Forward-coupling ceramic capacitors are connected across successive switch-capacitor-switch stages to assist in switching. Pressurized SF, gas is used for electrical insulation in the spark-gap switches and throughout the unit. The pressure housing is constructed entirely of dielectric materials, with segments that interlock with the low-profile switch bodies to provide an integrated support structure for all of the components. This ultra-compact Marx generator employs a modular design that can be sized as needed for a particular application. Units have been assembled with 4, 10, and 30 stages and operated at levels up to 100 kV per stage.

Goerz, D; Ferriera, T; Nelson, D; Speer, R; Wilson, M

2001-06-15T23:59:59.000Z

290

Current-Voltage and Capacitance-Voltage characteristics of Pd ...  

Science Conference Proceedings (OSTI)

Presentation Title, Current-Voltage and Capacitance-Voltage characteristics of Pd ... Nonlocal Modeling in High Rate Deformation and Ductile Fracture of ...

291

Armored instrumentation cable for geothermal well logging  

DOE Green Energy (OSTI)

Multiconductor armored well-logging cable is used extensively by the oil and natural gas industry to lower various instruments used to measure the geological and geophysical parameters into deep wellbores. Advanced technology in oil-well drilling makes it possible to achieve borehole depths of 9 km (30,000 ft). The higher temperatures in these deeper boreholes demand advancements in the design and manufacturing of wireline cable and in the electrical insulating and armoring materials used as integral components. If geothermal energy is proved an abundant economic resource, drilling temperatures approaching and exceeding 300/sup 0/C will become commonplace. The adaptation of teflons as electrical insulating material permitted use of armored cable in geothermal wellbores where temperatures are slightly in excess of 200/sup 0/C, and where the concentrations of corrosive minerals and gases are high. Teflon materials presently used in wireline cables, however, are not capable of continuous operation at the anticipated higher temperatures.

Dennis, B.R.; Johnson, J.; Todd, B.

1981-01-01T23:59:59.000Z

292

A low-power, high-bandwidth LDO voltage regulator with no external capacitor  

E-Print Network (OSTI)

A low-dropout (LDO) voltage regulator for low-power applications is designed without an external capacitor for compensation. The regulator has two stages, the first a folded cascode amplifier and the second a large pass ...

Ha, Miranda J. (Miranda Joy)

2008-01-01T23:59:59.000Z

293

Effect of MOSFET threshold voltage variation on high-performance circuits  

E-Print Network (OSTI)

The driving force for the semiconductor industry growth has been the elegant scaling nature of CMOS technology. In future CMOS technology generations, supply and threshold voltages will have to continually scale to sustain ...

Narendra, Siva G. (Siva Gurusami), 1971-

2002-01-01T23:59:59.000Z

294

Assessment of research directions for high-voltage direct-current power systems. Final report  

Science Conference Proceedings (OSTI)

High voltage direct current (HVDC) power transmission continues to be an emerging technology nearly thirty years after its introduction into modern power systems. To date its use has been restricted to either specialized applications having identifiable economic advantages (e.g., breakeven distance) or, rarely, applications where decoupling is needed. Only recently have the operational advantages (e.g., power modulation) of HVDC been realized on operating systems. A research project whose objective was to identify hardware developments and, where appropriate, system applications which can exemplify cost and operational advantages of integrated ac/dc power systems is discussed. The three principal tasks undertaken were: assessment of equipment developments; quantification of operational advantages; and interaction with system planners. Interest in HVDC power transmission has increased markedly over the past several years, and many new systems are now being investigated. The dissemination of information about HVDC, including specifically the symposium undertaken for Task 3, is a critical factor in fostering an understanding of this important adjunct to ac power transmission.

Long, W F

1982-09-01T23:59:59.000Z

295

The Cabling Handbook  

Science Conference Proceedings (OSTI)

From the Book:PREFACE: IntroductionThe cabling industry is becoming a full-service provider as it evolves its infrastructure into an all-digital superhighway. Both the telephone and computer industries are suggesting that their networking ...

John R. Vacca

1998-09-01T23:59:59.000Z

296

Superconducting Power Cables  

Science Conference Proceedings (OSTI)

This report is the fourth installment of a Technology Watch series on Superconducting Power Cables that summarize full-scale superconducting cable projects throughout the world. The series provides an overview of technical fundamentals and status updates on ongoing development efforts ranging from full-scale test installations to grid-deployed demonstration projects. This installment of the series covers ongoing full-scale utility installations and proposed demonstration projects worldwide. Information a...

2009-12-23T23:59:59.000Z

297

Cable Reliability Management Strategies  

Science Conference Proceedings (OSTI)

In previous collaborative research with several utilities, EPRI developed methods for forecasting the failures and cash flows associated with managing a population of underground cable. This study builds on that research and provides a method for developing least-cost repair and replacement policies for such a population. The policies specify when to replace a cable section or an entire circuit, depending on the age of the section and the number of failures the section has experienced.

2003-12-10T23:59:59.000Z

298

Correction coil cable  

DOE Patents (OSTI)

The present invention relates generally to the field of the manufacture of electrical coil windings, and more particularly to a unique cable assembly for use in winding coils having small wires and a large number of winding turns. The predominant current usage of the correction coil cable of the present invention is as the winding wire for correction coils in the superconducting super collider and in similar devices which might be developed in the future.

Wang, Sou-Tien

1991-04-09T23:59:59.000Z

299

Research on Fault Diagnosis on High Voltage SF6 Circuit Breaker Based on the Db Wavelet and Fuzzy Theory  

Science Conference Proceedings (OSTI)

This dissertation aims at providing a quick and accurate fault diagnosis method for on high voltage SF6circuit breaker. This method indirectly monitors the functioning of the breaker by observing the electric current in the coil of its switch. The electrical ... Keywords: SF6 circuit breaker, monitor, wavelet transform, fuzzy theory

Li Yang; Zhuo Yang; Yang Lei; Kejie Dai; Weiming Guan

2012-05-01T23:59:59.000Z

300

A three-level buck converter to regulate a high-voltage DC-to-AC inverter  

E-Print Network (OSTI)

A three-level buck converter is designed and analyzed, and shown to be suitable as a high-voltage down converter as a pre-regulation stage for a 600 watt DC-to-AC power inverter. Topology selection for the inverter is ...

Schrock, Kenneth C

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Laser-Triggered Lightning Laboratory Tests: Preparation for Testing at Mississippi State University High-Voltage Laboratory  

Science Conference Proceedings (OSTI)

Lightning diversion using laser technology could be operationally used in the power industry to protect sensitive facilities such as nuclear power plants and critical substations, control centers, and customer facilities. This report provides results to date and plans for large-scale, high-voltage laboratory testing of laser-triggered lightning technology.

1998-01-15T23:59:59.000Z

302

HTS Cable Projects | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Cable Projects HTS Cable Projects Fact sheet describing what is being done to modernize electricity transmission and distribution HTS Cable Projects More Documents & Publications...

303

Development of superconducting transmission cable. CRADA final report  

SciTech Connect

The purpose of this Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and Southwire Company is to develop the technology necessary to proceed to commercialization of high-temperature superconducting (HTS) transmission cables. Power transmission cables are a promising near-term electric utility application for high-temperature superconductivity. Present HTS wires match the needs for a three-phase transmission cable: (1) the wires must conduct high currents in self-field, (2) there are no high forces developed, and (3) the cables may operate at relatively low current density. The commercially-available HTS wires, in 100-m lengths, make construction of a full three-phase, alternating current (ac) transmission cable possible. If completed through the pre-commercialization phase, this project will result in a new capability for electric power companies. The superconducting cable will enable delivery with greater efficiency, higher power density, and lower costs than many alternatives now on the market. Job creation in the US is expected as US manufacturers supply transmission cables to the expanding markets in Asia and to the densely populated European cities where pipe-type cable is prevalent. Finally, superconducting cables may enable delivery of the new, diverse and distributed sources of electricity that will constitute the majority of new installed electrical generation in the world during the coming decades.

Hawsey, R.; Stovall, J.P. [Oak Ridge National Lab., TN (United States); Hughey, R.L.; Sinha, U.K. [Southwire Co., Carrollton, GA (United States)

1997-10-01T23:59:59.000Z

304

Characterization of the Li(Si)/CoS(2) couple for a high-voltage, high-power thermal battery  

DOE Green Energy (OSTI)

In order to determined the capabilities of a thermal battery with high-voltage and high-power requirements, a detailed characterization of the candidate LiSi/LiCl-LiBr-LiF/CoS{sub 2} electrochemical couple was conducted. The rate capability of this system was investigated using 0.75 inch-dia. and 1.25 inch-dia. single and multiple cells under isothermal conditions, where the cells were regularly pulsed at increasingly higher currents. Limitations of the electronic loads and power supplies necessitated using batteries to obtain the desired maximum current densities possible for this system. Both 1.25 inch-dia. and 3 inch-dia. stacks were used with the number of cells ranging from 5 to 20. Initial tests involved 1.25 inch-dia. cells, where current densities in excess of 15 A/cm{sup 2} (>200 W/cm{sup 2}) were attained with 20-cell batteries during 1-s pulses. In subsequent follow-up tests with 3 inch-dia., 10-cell batteries, ten 400-A 1-s pulses were delivered over an operating period often minutes. These tests formed the foundation for subsequent full-sized battery tests with 125 cells with this chemistry.

GUIDOTTI,RONALD A.; REINHARDT,FREDERICK W.

2000-02-01T23:59:59.000Z

305

Best Practices for HPFF Pipe Type Cable Assessment, Maintenance and Testing: Blenheim-Gilboa 345-kV Cable Systems  

Science Conference Proceedings (OSTI)

EPRI and the New York Power Authority (NYPA) have sponsored an extensive series of tests on the NYPA Blenheim-Gilboa 345-kV high-pressure fluid-filled (HPFF) transmission cable systems to determine their condition. Several tests were also designed to determine cable power transfer capability based on distributed temperature measurements and to improve the best maintenance practices for the Blenheim-Gilboa HPFF cable systems.

2005-03-01T23:59:59.000Z

306

High voltage capability electrical coils insulated with materials containing SF.sub.6 gas  

DOE Patents (OSTI)

A coil is made having a plurality of layers of adjacent metal conductor windings subject to voltage stress, where the windings have insulation therebetween containing a small number of minute disposed throughout its cross-section, where the voids are voids filled with SF.sub.6 gas to substitute for air or other gaseous materials in from about 60% to about 95% of the cross-sectional void volume in the insulation, thus incorporating an amount of SF.sub.6 gas in the cross-section of the insulation effective to substantially increase corona inception voltages.

Lanoue, Thomas J. (Muncie, IN); Zeise, Clarence L. (Penn Township, Allegheny County, PA); Wagenaar, Loren (Muncie, IN); Westervelt, Dean C. (Acme, PA)

1988-01-01T23:59:59.000Z

307

Project Fact Sheet Columbus HTS Power Cable Superconductivity  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Columbus Columbus HTS Power Cable Superconductivity Partnerships with Industry www.oe.energy.gov Phone: 202 \ 586-1411 Office of Electricity Delivery and Energy Reliability, OE-1 U.S. Department of Energy - 1000 Independence Avenue, SW - Washington, DC 20585 Plugging America Into the Future of Power This project involves field-testing of a long-length high-temperature superconducting (HTS) cable under real environmental stresses and real electrical loads. The cable system forms an important electrical link in a util- ity substation in Columbus, Ohio. What are its Primary aPPlications? HTS power cables are used for electricity transmission and distribution. The Columbus cable is a distribution cable, conducting electricity within a local grid. What are the Benefits to Utilities?

308

PRESENT AND FUTURE TECHNOLOGY OF HIGH VOLTAGE SYSTEMS FOR NEUTRAL BEAM INJECTORS  

E-Print Network (OSTI)

savings tn the power conditioning transformers would result.power supply would be extremely simple, involving as major components only primary contactors, voltage-variable transformer,transformer reactance. For the LBL 160-kV, 75-A NBSTF Accel power

Baker, W.R.

2011-01-01T23:59:59.000Z

309

Correction coil cable  

DOE Patents (OSTI)

A wire cable assembly (10, 310) adapted for the winding of electrical coils is taught. A primary intended use is for use in particle tube assemblies (532) for the superconducting super collider. The correction coil cables (10, 310) have wires (14, 314) collected in wire arrays (12, 312) with a center rib (16, 316) sandwiched therebetween to form a core assembly (18, 318 ). The core assembly (18, 318) is surrounded by an assembly housing (20, 320) having an inner spiral wrap (22, 322) and a counter wound outer spiral wrap (24, 324). An alternate embodiment (410) of the invention is rolled into a keystoned shape to improve radial alignment of the correction coil cable (410) on a particle tube (733) in a particle tube assembly (732).

Wang, Sou-Tien (Danville, CA)

1994-11-01T23:59:59.000Z

310

A new converter fault discrimination method for a 12-pulse high-voltage direct current system based on wavelet transform and Hidden Markov Models  

Science Conference Proceedings (OSTI)

The progressive development in high-voltage direct current (HVDC) transmission enhances the need to implement an efficient protection scheme to distinguish the minimum faulty part of the system and to relieve the stressed equipment. This paper proposes ... Keywords: Discrete Hidden Markov Models, converter faults, fault discrimination, high-voltage direct current, wavelet transform

Mohamad Tahan; Hassan Monsef; Shahrokh Farhangi

2012-06-01T23:59:59.000Z

311

Coaxial cable cutter  

DOE Patents (OSTI)

A cutting device is provided which is useful in trimming the jackets from semi-rigid coaxial cables and wire having a cutting bit and support attached to movable jaws. A thumbpiece is provided to actuate the opening of the jaws for receiving the cable to be trimmed, and a spring member is provided to actuate the closing of the jaws when thumbpiece is released. The cutting device utilizes one moving part during the cutting operation by using a rolling cut action. The nature of the jaws allows the cutting device to work in space having clearances less than 0.160 inches.

Hall, Leslie C. (Grandview, MO); Hedges, Robert S. (Belton, MO)

1990-04-10T23:59:59.000Z

312

EPRI Comments on a French Study of Residential Proximity to High-Voltage Power Lines and Childhood Leukemia  

Science Conference Proceedings (OSTI)

Results of a French case-control epidemiologic study of residential proximity to high-voltage power lines and risk of childhood acute leukemia were published in the British Journal of Cancer.  The EPRI Comments provides background information on the study, summarizes the main results and discusses the study’s strength and limitations. The EPRI Comments also highlights an ongoing EPRI-funded epidemiologic study in California that is expected to provide further insight ...

2013-04-23T23:59:59.000Z

313

High-Voltage Direct Current Corona Testing of Transmission Line Hardware and Insulator Assemblies: Development of Test Methodology  

Science Conference Proceedings (OSTI)

When specifying hardware for new high-voltage direct current (HVDC) lines or replacement hardware for existing HVDC lines utilities generally require that the hardware meet specific corona performance requirements.While standards and test methods exist for testing hardware used on HVAC systems, no such material is available for HVDC systems.HVAC tests are sometimes conducted on the hardware and the results obtained are then related to HVDC by utilizing the peak HVAC line to ...

2013-12-20T23:59:59.000Z

314

EPRI Comments on a UK Case-Control Study of Magnetic Fields from High Voltage Power Lines and Childhood Cancer  

Science Conference Proceedings (OSTI)

A paper, entitled "Childhood cancer and magnetic fields from high voltage power lines in England and Wales: a case-control study," was published in the British Journal of Cancer on September 28, 2010. The authors assessed the association between exposure to EMF from power lines at the address of birth and childhood cancer. The current paper provides additional results to a study published earlier from the same data set in 2005. These EPRI comments provide an overview of study findings, conclusions, stren...

2010-12-22T23:59:59.000Z

315

Underground Distribution Cable Fleet Management  

Science Conference Proceedings (OSTI)

This report describes industry research and data collection related to distribution cable system management. Focus areas include international practices for cable system management, international research activities, and application of diagnostic testing techniques. This report is a follow-up to the 2010 effort to catalog leading practices for distribution cable fleet management.

2011-12-15T23:59:59.000Z

316

Oxidation Potentials of Functionalized Sulfone Solvents for High-Voltage Li-Ion Batteries: A Computational Study  

Science Conference Proceedings (OSTI)

New electrolytes with large electrochemical windows are needed to meet the challenge for high-voltage Li-ion batteries. Sulfone as an electrolyte solvent boasts of high oxidation potentials. Here we examine the effect of multiple functionalization on sulfone's oxidation potential. We compute oxidation potentials for a series of sulfone-based molecules functionalized with fluorine, cyano, ester, and carbonate groups by using a quantum chemistry method within a continuum solvation model. We find that multifunctionalization is a key to achieving high oxidation potentials. This can be realized through either a fluorether group on a sulfone molecule or sulfonyl fluoride with a cyano or ester group.

Shao, Nan [ORNL; Sun, Xiao-Guang [ORNL; Dai, Sheng [ORNL; Jiang, Deen [ORNL

2012-01-01T23:59:59.000Z

317

Characteristics of Pipe-Type Cable Fluids and Development of Risk-Based Cleanup Goals: Interim Report  

Science Conference Proceedings (OSTI)

Underground transmission cables transmit electricity in many urban areas of the United States. In high-pressure fluid-filled (HPFF) pipe-type cables, the cable interior is filled with insulating fluid. Occasionally, cables can leak, and the fluid can contaminate surrounding soil. This report presents interim results of a project to characterize the physical and chemical properties of HPFF cable fluids, evaluate their fate and transport in the environment, and develop soil cleanup levels for the fluids th...

2002-03-06T23:59:59.000Z

318

Network Cabling Handbook  

Science Conference Proceedings (OSTI)

From the Publisher:This is a one-stop guide to both copper and fiber network cabling. Contains detailed coverage of monitoring software,connectivity troubleshooting,and management techniques. Master the art of wiring your network Plan,design,and build ...

Chris Clark

2001-11-01T23:59:59.000Z

319

Ultra High Voltage Transmission Technology : Italy-USA Joint Workshop, July 26-28, 1982, Hilton Hotel, Portland, Oregon, USA.  

SciTech Connect

Twenty-five papers are presented in the following areas: electric field effects, overhead lines, substations and cables, and electric load modeling. One US DOE paper is processed separately. (DLC)

United States. Bonneville Power Administration; Ente Nazionale Per L' Energia Elettrica.

1982-01-01T23:59:59.000Z

320

Disposable telemetry cable deployment system  

DOE Patents (OSTI)

A disposable telemetry cable deployment system for facilitating information retrieval while drilling a well includes a cable spool adapted for insertion into a drill string and an unarmored fiber optic cable spooled onto the spool cable and having a downhole end and a stinger end. Connected to the cable spool is a rigid stinger which extends through a kelly of the drilling apparatus. A data transmission device for transmitting data to a data acquisition system is disposed either within or on the upper end of the rigid stinger.

Holcomb, David Joseph (Sandia Park, NM)

2000-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

A monitor and control system for high voltage, gating, and triggering of a scintillating fiber active target  

SciTech Connect

A monitor and control system has been designed, constructed and tested at Notre Dame for the purpose of controlling all aspects of a Scintillating Fiber Acxtive Target system used in High Energy Physics Experimentation. The SFT Active Target system requires control of high voltages, gating, trigger counters, and monitoring. In addition, it resides in a radioactive area with very limited access. The control system uses a Leading Edge microcomputer, two specialized Z80-based processors, associated DACs, ADCs, discrete semiconductors, linear ICs and TTL and MECL logic. All of the hardware and software is custom-built; its design and performance is discussed.

Baumbaugh, B.; Bishop, J.; Gardner, R.W.; Mountain, R.J.; Ruchti, R.; Baumbaugh, A.; Knickerbocker, K.

1988-02-01T23:59:59.000Z

322

A monitor and control system for high voltage, gating, and triggering of a scintillating fiber active target  

SciTech Connect

A monitor and control system has been designed, constructed and tested at Notre Dame for the purpose of controlling all aspects of a Scintillating Fiber Active Target system used in High Energy Physics Experimentation. The SFT Active Target system requires control of high voltages, gating, trigger counters, and monitoring. In addition, it resides in a radioactive area with very limited access. The control system uses a Leading Edge microcomputer, two specialized Z80-based processors, associated DACs, ADCs, discrete semiconductors, linear ICs, and TTL and MECL logic. All of the hardware and software is custom-built; its design and performance is discussed. 5 refs., 4 figs.

Baumbaugh, B.; Bishop, J.; Gardner, R.W.; Mountain, R.J.; Ruchti, R.; Baumbaugh, A.; Knickerbocker, K.

1987-10-01T23:59:59.000Z

323

Determination of the cathode and anode voltage drops in high power low-pressure amalgam lamps  

Science Conference Proceedings (OSTI)

For the first time, cathode and anode drops of powerful low-pressure amalgam lamps were measured. The lamp discharge current is 3.2 A, discharge current frequency is 43 kHz, linear electric power is 2.4 W/cm. The method of determination of a cathode drop is based on the change of a lamp operating voltage at variation of the electrode filament current at constant discharge current. The total (cathode plus anode) drop of voltage was measured by other, independent ways. The maximum cathode fall is 10.8 V; the anode fall corresponding to the maximal cathode fall is 2.4 V. It is shown that in powerful low pressure amalgam lamps the anode fall makes a considerable contribution (in certain cases, the basic one) to heating of electrodes. Therefore, the anode fall cannot be neglected, at design an electrode and ballast of amalgam lamps with operating discharge current frequency of tens of kHz.

Vasilyak, L. M., E-mail: vasilyak@ihed.ras.ru [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation); Vasiliev, A. I., E-mail: vasiliev@npo.lit.ru; Kostyuchenko, S. V.; Sokolov, D. V.; Startsev, A. Yu. [Joint Stock Company NPO LIT (Russian Federation); Kudryavtsev, N. N. [Moscow Institute of Physics and Technology (State University) (Russian Federation)

2011-12-15T23:59:59.000Z

324

Optical voltage reference  

DOE Patents (OSTI)

An optical voltage reference for providing an alternative to a battery source. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function.

Rankin, R.; Kotter, D.

1992-12-31T23:59:59.000Z

325

Optical voltage reference  

DOE Patents (OSTI)

An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

Rankin, R.; Kotter, D.

1994-04-26T23:59:59.000Z

326

Active filters for high-voltage direct-current (HVDC) converter terminals: Final report  

SciTech Connect

This report evaluates the technical and economic feasibility for active filtering of dc-side voltage harmonics and the ac-side current harmonics produced by a HVDC converter. The following designs for the active filter concepts are compared with the existing ac-side and dc-side passive filters used at the Dickinson terminal of the CU HVDC transmission line project: the dc-side active filter consisting of a capacitor coupled current injection source to actively ''neutralize'' the 12th, 24th and the 36th harmonics and, the ac-side active filter designed to provide the same fundamental frequency reactive VARs as the existing passive filters. Controlled currents are injected to actively filter the 11th and the 13th harmonic currents. A cost comparison is made between these active filter designs and existing passive filters supplied by the United Power Association (UPA). 22 figs., 11 tabs.

Mohan, N.; Wong, C.

1988-08-01T23:59:59.000Z

327

SF6 dielectric behavior in a high voltage circuit breaker at low temperature under lightning impulses  

Science Conference Proceedings (OSTI)

This work concerns the study of the dielectric and thermodynamic behavior of SF{sub 6} in a 145 kV circuit breaker subjected to lightning impulse voltages in both polarities at temperatures varying from ambient (20 C) to {minus}45 C. The filling of the circuit breaker with SF{sub 6} is carried out at the reference point: T = 15 C, P = 6 bars abs. and d = 39.6 kg/m{sup 3}. Devices allowing to detect the appearance of local condensation of SF{sub 6} and to identify the breakdown between the circuit-breaker contacts and the flashover outside the circuit-breaker, are presented. The experimental results show a general tendency to a decrease in the U{sub 50%} voltage when the temperature is decreased at constant density (a decrease by about 5% when the temperature was decreased from +20 C to {minus}25 C). Such a variation would not have a significant influence in industrial practice. Even if this variation is very weak, it also appears from the obtained results that the gas density is not the only parameter which has an influence on the electric strength of the gas. However, to compare results at different temperatures, it would be better to make it at constant density and not at constant pressure, to avoid the dependency of the ratio (E/N) on N (where E is the electric strength and N the density). On the other hand, it seems that the presence of the liquid in the circuit breaker is not a penalizing parameter. The distribution of the electric field corresponding to the geometrical configuration of the studied circuit-breaker is also presented.

Buret, F.; Beroual, A. [Ecole Centrale de Lyon, Ecully (France)

1996-01-01T23:59:59.000Z

328

Method to improve superconductor cable  

DOE Patents (OSTI)

A method is disclosed of making a stranded superconductor cable having improved flexing and bending characteristics. In such method, a plurality of superconductor strands are helically wound around a cylindrical portion of a mandrel which tapers along a transitional portion to a flat end portion. The helically wound strands form a multistrand hollow cable which is partially flattened by pressure rollers as the cable travels along the transitional portion. The partially flattened cable is impacted with repeated hammer blows as the hollow cable travels along the flat end portion. The hammer blows flatten both the internal and the external surfaces of the strands. The cable is fully flattened and compacted by two sets of pressure rollers which engage the flat sides and the edges of the cable after it has traveled away from the flat end portion of the mandrel. The flattened internal surfaces slide easily over one another when the cable is flexed or bent so that there is very little possibility that the cable will be damaged by the necessary flexing and bending required to wind the cable into magnet coils.

Borden, A.R.

1984-03-08T23:59:59.000Z

329

Charge Lifetime Study of K2CsSb Photocathode Inside a JLAB DC High Voltage Gun  

SciTech Connect

Two photocathodes are frequently considered for generating high average current electron beams and/or beams with high brightness for current and future accelerator applications: GaAs:Cs and K2CsSb. Each photocathode has advantages and disadvantages, and need to demonstrate performance at 'production' accelerator facilities. To this end a K2CsSb photocathode was manufactured at Brookhaven National Lab and delivered to Jefferson Lab within a compact vacuum apparatus at pressure {approx} 5 x 10{sup -11} Torr. This photocathode was installed inside a dc high voltage photogun biased at voltages up to 200 kV, and illuminated with laser light at 440 or 532 nm, to generate beams up to 20 mA. Photocathode charge lifetime measurements indicate that under some conditions this cathode has exceptionally high charge lifetime, without measurable QE decay, even from the center of the photocathode where operation using GaAs photocathodes is precluded due to ion bombardment. These studies also suggest a complex QE decay mechanism likely related to chemistry and localized heating via the laser beam.

Mammei, R.; Rao, T.; Suleiman, R.; Poelker, M.; Smedley, J.; McCarter, J.L.

2011-10-01T23:59:59.000Z

330

Thermal management of long-length HTS cable systems  

Science Conference Proceedings (OSTI)

Projections of electric power production suggest a major shift to renewables, such as wind and solar, which will be in remote locations where massive quantities of power are available. One solution for transmitting this power over long distances to load centers is direct current (dc), high temperature superconducting (HTS) cables. Electric transmission via dc cables promises to be effective because of the low-loss, highcurrent- carrying capability of HTS wire at cryogenic temperatures. However, the thermal management system for the cable must be carefully designed to achieve reliable and energyefficient operation. Here we extend the analysis of a superconducting dc cable concept proposed by the Electric Power Research Institute (EPRI), which has one stream of liquid nitrogen flowing in a cryogenic enclosure that includes the power cable, and a separate return tube for the nitrogen. Refrigeration stations positioned every 10 to 20 km cool both nitrogen streams. Both go and return lines are contained in a single vacuum/cryogenic envelope. Other coolants, including gaseous helium and gaseous hydrogen, could provide potential advantages, though they bring some technical challenges to the operation of long-length HTS dc cable systems. A discussion of the heat produced in superconducting cables and a system to remove the heat are discussed. Also, an analysis of the use of various cryogenic fluids in long-distance HTS power cables is presented.

Demko, Jonathan A [ORNL; Hassenzahl, William V [ORNL

2011-01-01T23:59:59.000Z

331

Recommended practice for fire protection for electric generating plants and high voltage direct current converter stations. 2005 ed.  

Science Conference Proceedings (OSTI)

The standard outlines fire safety recommendations for gas, oil, coal, and alternative fuel electric generating plants including high voltage direct current converter stations and combustion turbine units greater than 7500 hp used for electric generation. Provisions apply to both new and existing plants. The document provides fire prevention and fire protection recommendations for the: safety of construction and operating personnel; physical integrity of plant components; and continuity of plant operations. The 2005 edition includes revisions and new art that clarify existing provisions. 5 annexes.

NONE

2005-07-01T23:59:59.000Z

332

Experimental investigation of dielectric barrier discharge plasma actuators driven by repetitive high-voltage nanosecond pulses with dc or low frequency sinusoidal bias  

Science Conference Proceedings (OSTI)

Experimental studies were conducted of a flow induced in an initially quiescent room air by a single asymmetric dielectric barrier discharge driven by voltage waveforms consisting of repetitive nanosecond high-voltage pulses superimposed on dc or alternating sinusoidal or square-wave bias voltage. To characterize the pulses and to optimize their matching to the plasma, a numerical code for short pulse calculations with an arbitrary impedance load was developed. A new approach for nonintrusive diagnostics of plasma actuator induced flows in quiescent gas was proposed, consisting of three elements coupled together: the schlieren technique, burst mode of plasma actuator operation, and two-dimensional numerical fluid modeling. The force and heating rate calculated by a plasma model was used as an input to two-dimensional viscous flow solver to predict the time-dependent dielectric barrier discharge induced flow field. This approach allowed us to restore the entire two-dimensional unsteady plasma induced flow pattern as well as characteristics of the plasma induced force. Both the experiments and computations showed the same vortex flow structures induced by the actuator. Parametric studies of the vortices at different bias voltages, pulse polarities, peak pulse voltages, and pulse repetition rates were conducted experimentally. The significance of charge buildup on the dielectric surface was demonstrated. The charge buildup decreases the effective electric field in the plasma and reduces the plasma actuator performance. The accumulated surface charge can be removed by switching the bias polarity, which leads to a newly proposed voltage waveform consisting of high-voltage nanosecond repetitive pulses superimposed on a high-voltage low frequency sinusoidal voltage. Advantages of the new voltage waveform were demonstrated experimentally.

Opaits, Dmitry F.; Likhanskii, Alexandre V.; Neretti, Gabriele; Zaidi, Sohail; Shneider, Mikhail N.; Miles, Richard B. [Mechanical and Aerospace Engineering, Princeton University, Princeton, New Jersey 08544 (United States); Macheret, Sergey O. [Lockheed Martin Aeronautics Company, Palmdale, California 93599 (United States)

2008-08-15T23:59:59.000Z

333

Analysis of system wide distortion in an integrated power system utilizing a high voltage DC bus and silicon carbide power devices  

E-Print Network (OSTI)

This research investigates the distortion on the electrical distribution system for a high voltage DC Integrated Power System (IPS). The analysis was concentrated on the power supplied to a propulsion motor driven by an ...

Fallier, William F. (William Frederick)

2007-01-01T23:59:59.000Z

334

Observations of Transport Variability in the Baltic Sea by Parasitic Use of a Fiber-Optic Cable  

Science Conference Proceedings (OSTI)

Transports between the Swedish mainland and the island of Gotland were studied by means of motionally induced voltages. The copper mantle of an existent fiber-optic telecommunications cable was grounded on Gotland, and the data acquisition system ...

Peter Sigray; Peter Lundberg; Kristofer Döös

2004-07-01T23:59:59.000Z

335

Analog Integrated Circuits and Signal Processing, 42, 231–238, 2005 c ? 2005 Springer Science + Business Media, Inc. Manufactured in The Netherlands. Cascode Monolithic DC-DC Converter for Reliable Operation at High Input Voltages  

E-Print Network (OSTI)

Abstract. A cascode bridge circuit for monolithic switching DC-DC converters operating at high input voltages is proposed in this paper. The proposed circuit can also be used as an I/O buffer to interface circuits operating at significantly different voltages. The circuit technique permits the full integration of the active and passive devices of a switching DC-DC converter with a high voltage conversion ratio in a standard low voltage CMOS technology. The cascode bridge structure guarantees the reliable operation of deep submicrometer MOSFETs without exposure to high voltage stress while operating at high input and output voltages. With the proposed circuit technique, steady-state voltage differences between the terminals of all of the MOSFETs in a switching DC-DC converter are maintained within a range imposed by a target low voltage CMOS technology. High-to-low DC-DC converters operating at input voltages up to three times as high as the maximum voltage that can be directly applied across the terminals of a MOSFET are described. An efficiency of 79.6 % is achieved for 5.4 volts to 0.9 volts conversion assuming a 0.18 µm CMOS technology. The DC-DC converter operates at a switching frequency of 97 MHz while supplying a DC current of 250 mA to the load. Key Words: low voltage DC-DC converters, monolithic voltage regulators, low voltage CMOS technology, MOSFET reliability issues, high voltage stress 1.

Volkan Kursun; Siva G. Narendra; Vivek K. De; Eby G. Friedman

2004-01-01T23:59:59.000Z

336

Improved Off-State Stress Critical Voltage on AlGaN/GaN High Electron Mobility Transistors Utilizing Pt/Ti/Au Based Gate Metallization  

Science Conference Proceedings (OSTI)

The critical voltage for degradation of AlGaN/GaN high electron mobility transistors (HEMTs) employed with the Pt/Ti/Au gate metallization instead of the commonly used Ni/Au was significantly increased during the off-state stress. The typical critical voltage for HEMTs with Ni/Au gate metallization was around -60V. By sharp contrast, no critical voltage was observed for the HEMTs with Pt/Ti/Au gate metallization, even up to -100V, which was the instrumental limitation in this experiment. Both Schottky forward and reverse gate characteristics of the Ni/Au degraded once the gate voltage passed the critical voltage of around -60V. There was no degradation exhibited for the HEMTs with Pt-gated HEMTs.

Lo, C. F. [University of Florida; Liu, L. [University of Florida, Gainesville; Kang, Tsung Sheng [University of Florida, Gainesville; Davies, Ryan [University of Florida; Gila, Brent P. [University of Florida, Gainesville; Pearton, S. J. [University of Florida; Kravchenko, Ivan I [ORNL; Laboutin, O. [Kopin Corporation, Taunton, MA; Cao, Yu [Kopin Corporation, Taunton, MA; Johnson, Wayne J. [Kopin Corporation, Taunton, MA; Ren, F. [University of Florida

2011-01-01T23:59:59.000Z

337

Differential voltage analyses of high-power lithium-ion cells 4. Cells containing NMC.  

DOE Green Energy (OSTI)

Cells with and without a LiC{sub 2}O{sub 4}BF{sub 2} electrolyte additive and that contained Li{sub 1.05}(Mn{sub 1/3}Co{sub 1/3}Ni{sub 1/3}){sub 0.95}O{sub 2} (NMC) positive electrodes were tested for calendar and cycle life at 60% state of charge. The temperatures used in these tests were 25 and 45 C (cycle life) and 45 and 55 C (calendar life). An analysis of the C/25 capacity data shows that the C/25 capacity decreases with the square root of time. The additive slowed down the rate of capacity decline. The C/25 data were subjected to differential voltage analysis to determine the possible cause of the capacity decrease and at which electrode the capacity decrease was occurring. Data from full cells and half-cells were compared to elucidate individual electrode contributions. This analysis indicated that lithium-capacity-consuming side reactions were occurring primarily at the negative electrode.

Bloom, I.; Walker, L. K.; Basco, J. K.; Abraham, D. P.; Christophersen, J. P.; Ho, C. D.; Chemical Sciences and Engineering Division; INL

2010-02-01T23:59:59.000Z

338

Microminiature coaxial cable and methods manufacture  

DOE Patents (OSTI)

A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 [mu]m thick and from 150 to 200 [mu]m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microballoons to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion. 2 figs.

Bongianni, W.L.

1986-04-08T23:59:59.000Z

339

Holbrook Substation Superconductor Cable System, Long Island, New York Final Report  

SciTech Connect

The LIPA Superconductor project broke ground on July 4, 2006, was first energized on April 22, 2008 (Earth Day) and was commissioned on June 25, 2008. Since commissioning, up until early March, 2009, there were numerous refrigeration events that impacted steady state operations. This led to the review of the alarms that were being generated and a rewrite of the program logic in order to decrease the hypersensitivity surrounding these alarms. The high temperature superconductor (HTS) cable was energized on March 5, 2009 and ran uninterrupted until a human error during a refrigeration system switchover knocked the cable out of the grid in early February 2010. The HTS cable was in the grid uninterrupted from March 5, 2009 to February 4, 2010. Although there have been refrigeration events (propagated mainly by voltage sags/surges) during this period, the system was able to automatically switch over from the primary to the backup refrigeration system without issue as required during this period. On February 4, 2010, when switching from the backup over to the primary refrigeration system, two rather than one liquid nitrogen pumps were started inadvertently by a human error (communication) causing an overpressure in the cable cooling line. This in turn activated the pressure relief valve located in the grounding substation. The cable was automatically taken out of the grid without any damage to the components or system as a result of signals sent from the AMSC control cabinet to the LIPA substation. The cable was switched back into the grid again on March 16, 2010 without incident and has been operational since that time. Since switching from the backup to the primary is not an automatic process, a recent improvement was added to the refrigeration operating system to allow remote commands to return the system from backup to primary cooling. This improvement makes the switching procedure quicker since travel to the site to perform this operation is no longer necessary and safer since it is now a programmed procedure versus the former written procedure that was still subject to human variation in the process.

Maguire, James; McNamara, Joseph

2010-06-25T23:59:59.000Z

340

Low Beam Voltage, 10 MW, L-Band Cluster Klystron  

SciTech Connect

Conceptual design of a multi-beam klystron (MBK) for possible ILC and Project X applications is presented. The chief distinction between this MBK design and existing 10-MW MBK's is the low operating voltage of 60 kV. There are at least four compelling reasons that justify development at this time of a low-voltage MBK, namely (1) no pulse transformer; (2) no oil tank for high-voltage components and for the tube socket; (3) no high-voltage cables; and (4) modulator would be a compact 60-kV IGBT switching circuit. The proposed klystron consists of four clusters containing six beams each. The tube has common input and output cavities for all 24 beams, and individual gain cavities for each cluster. A closely related optional configuration, also for a 10 MW tube, would involve four totally independent cavity clusters with four independent input cavities and four 2.5 MW output ports, all within a common magnetic circuit. This option has appeal because the output waveguides would not require a controlled atmosphere, and because it would be easier to achieve phase and amplitude stability as required in individual SC accelerator cavities.

Teryaev, V.; /Novosibirsk, IYF; Yakovlev, V.P.; /Fermilab; Kazakov, S.; /KEK, Tsukuba; Hirshfield, J.L.; /Yale U. /Omega-P, New Haven

2009-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

NETL: News Release - Experimental Fiber Optic Cables To Warn...  

NLE Websites -- All DOE Office Websites (Extended Search)

Release Date: January 21, 2003 Experimental Fiber Optic Cables To Warn of Potential Pipeline Damage First Field Test of High-Tech Method for Improving Safety of the Nation's Gas...

342

HTS Cable Projects  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Superconductivity Superconductivity Partnerships with Industry ANL Air Liquide DOE Golden LANL AEP ORNL Nexans Niagara Mohawk Super Power American Superconductor NYSERDA BOC Praxair W ? tion systems. This is the most the nation. W superconductivity? HTS Cable Projects www.oe.energy.gov Phone: 202 \ 586-1411 Office of Electricity Delivery and Energy Reliability, OE-1 U.S. Department of Energy - 1000 Independence Avenue, SW - Washington, DC 20585. Plugging America Into the Future of Power "A National Effort to Introduce New Technology into

343

A Tracker for the Mu3e Experiment based on High-Voltage Monolithic Active Pixel Sensors  

E-Print Network (OSTI)

The Mu3e experiment searches for the lepton flavour violating decay mu+ -> e+e-e+, aiming for a branching fraction sensitivity of 10^-16. This requires an excellent momentum resolution for low energy electrons, high rate capability and a large acceptance. In order to minimize multiple scattering, the amount of material has to be as small as possible. These challenges can be met with a tracker built from high-voltage monolithic active pixel sensors (HV-MAPS), which can be thinned to 50 um and which incorporate the complete read-out electronics on the sensor chip. To further minimise material, the sensors are supported by a mechanical structure built from 25 um thick Kapton foil and cooled with gaseous helium.

Berger, Niklaus; Bachmann, Sebastian; Kiehn, Moritz; Peri?, Ivan; Perrevoort, Ann-Kathrin; Philipp, Raphael; Schöning, André; Stumpf, Kevin; Wiedner, Dirk; Windelband, Bernd; Zimmermann, Marco

2013-01-01T23:59:59.000Z

344

A Tracker for the Mu3e Experiment based on High-Voltage Monolithic Active Pixel Sensors  

E-Print Network (OSTI)

The Mu3e experiment searches for the lepton flavour violating decay mu+ -> e+e-e+, aiming for a branching fraction sensitivity of 10^-16. This requires an excellent momentum resolution for low energy electrons, high rate capability and a large acceptance. In order to minimize multiple scattering, the amount of material has to be as small as possible. These challenges can be met with a tracker built from high-voltage monolithic active pixel sensors (HV-MAPS), which can be thinned to 50 um and which incorporate the complete read-out electronics on the sensor chip. To further minimise material, the sensors are supported by a mechanical structure built from 25 um thick Kapton foil and cooled with gaseous helium.

Niklaus Berger; Heiko Augustin; Sebastian Bachmann; Moritz Kiehn; Ivan Peri?; Ann-Kathrin Perrevoort; Raphael Philipp; André Schöning; Kevin Stumpf; Dirk Wiedner; Bernd Windelband; Marco Zimmermann

2013-09-30T23:59:59.000Z

345

Fragmentation of Thin Wires under High Voltage Pulses and Bipolar Fusion  

Science Conference Proceedings (OSTI)

In this article we present an alternative explanation of the phenomenon of wire fragmentation under high transient currents based on classical electromagnetism. We also explain how this phenomenon can be utilized as a primitive example of low energy-high power disruptive phenomena that can affect even nuclear matter.

Papageorgiou, C. D. [Dept. of Electrical and Electronic Engineering, National Technical University of Athens (Greece); Raptis, T. E. [Division of Applied Technologies, National Centre for Science and Research 'Demokritos', Patriarchou Grigoriou and Neapoleos, Athens (Greece)

2010-01-21T23:59:59.000Z

346

Columbus HTS Power Cable | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

real electrical loads. The cable system forms an important electrical link in a utility substation in Columbus, Ohio. Columbus HTS Power Cable More Documents & Publications...

347

Surge voltage suppression in residential power circuits  

Science Conference Proceedings (OSTI)

... Tran- sients in Low Voltage Supply Systems,'' The ... a high-voltage transformer for an oil furnace ... of service entrance SPD of 1960-1970 vintage were ...

2013-05-17T23:59:59.000Z

348

Partial discharges in low-voltage cables - Electrical Insulation ...  

Science Conference Proceedings (OSTI)

... Conference Record of the 1990 IEEE International Symposium on Electrical Insulation, Toronto ... to the con- ductor using a #60 twist drill in two of the ...

2013-05-17T23:59:59.000Z

349

Design issues in low-voltage high-speed current-mode logic buffers  

Science Conference Proceedings (OSTI)

A current-mode logic (CML) buffer is based on a simple differential circuit. This paper investigates important problems involved in the design of a CML buffer as well as a chain of tapered CML buffers. A new design procedure to systematically design ... Keywords: VLSI, current-mode logic, high-speed, integrated circuit, noise

Payam Heydari

2003-04-01T23:59:59.000Z

350

Effect of trapping on the critical voltage for degradation in gan high electron mobility transistors  

E-Print Network (OSTI)

We have performed V[subscript DS] = 0 V and OFF-state step-stress experiments on GaN-on-Si and GaN-on-SiC high electron mobility transistors under UV illumination and in the dark. We have found that for both stress conditions, ...

Demirtas, Sefa

351

H20: New Ceramic-matrix Composite for Low Voltage High Energy ...  

Science Conference Proceedings (OSTI)

C19: Dissolution Behavior of Cu Under Bump Metallization in Ball Grid Array Structure ... E11: Evolution of the Grain Boundary Character Distribution During Grain ... for High Volume and Fast Turnaround Automated Inline TEM Sample Preparation .... H2: Triboluminescent Smart Sensors for Structural Health Monitoring.

352

Analysis and design of a high-current, high-voltage accurate power supply for the APS storage ring  

SciTech Connect

There are 81 dipole magnets contained in the storage ring at the Advanced Photon Source (APS). These magnets are connected in series and are energized by only one 12-phase power supply. The eighty-first magnet is located in a temperature-controlled room with an NMR probe to monitor the magnetic field in the magnet and provide a reference signal for correction of the field drift due to aging of the components. The current in the magnets will be held at 497 A. The required current stability of the power supply is {plus_minus}30 ppM, the current reproducibility is {plus_minus}50 ppM, and the current ripple is {plus_minus}400 ppM. The voltage required to maintain such a current in the magnets is about 1700 V. Different schemes for regulating current in the magnets are studied. Pspice software is used to simulate the behavior and the design of such a power supply under different conditions. The pros and cons of each scheme will be given and the proper power and regulating scheme will be selected.

Fathizadeh, M.

1993-08-01T23:59:59.000Z

353

Corona and Motor Voltage Interim Report  

SciTech Connect

It has been suggested that to meet the FreedomCAR objectives for cost, size, weight, efficiency, and reliability higher buss voltages be utilized in HEV and FC automotive applications. The reasoning is that since electric power is equal to the product of voltage and current for a given power a higher voltage and lower current would result in smaller cable and inverter switching components. Consequently, the system can be lighter and smaller. On the other hand, higher voltages are known to require better and thicker electrical insulation that reduce the available slot area for motor windings. One cause of slow insulation breakdown is corona that gradually erodes the insulation and shortens the life expectancy of the motor. This study reports on the results of a study on corona initiating voltages for mush-wound and bobbin-wound stators. A unique testing method is illustrated.

Hsu, J.S.

2005-05-06T23:59:59.000Z

354

Fibre Optic Cables: Tapping into fibre optic cables  

Science Conference Proceedings (OSTI)

When researchers laid the first undersea communication cable in the 1850s, they could not have known how long distance communications would advance in the subsequent 150 years. Thick copper wire laid under the ocean began carrying telegraph signals around ...

Bernard Everett

2007-05-01T23:59:59.000Z

355

Power Plant Practices to Ensure Cable Operability  

Science Conference Proceedings (OSTI)

Installation practices as well as environmental conditions affect the operability of electrical cables in power plants. This report evaluates operability criteria for nuclear power plant cables, good practices for cable installation, and cable maintenance and surveillance. As a reference source for utility practices, this report suggests potential improvements that could benefit the industry.

1992-05-02T23:59:59.000Z

356

Normal-zone detection in tokamak superconducting magnets with Co- wound voltage sensors  

SciTech Connect

This paper discusses advantages and disadvantages of different locations of co-wound voltage sensors for quench detection in tokamak magnets with a cable-in-conduit conductor. The voltage sensor locations are analyzed and estimates of the anticipated noise vs. dB/dt are derived for transverse, parallel, and self fields. The LLNL Noise Rejection Experiment, also described here, is designed to verify theoretical expectations on a copper cable exposed to these fields that will simulate the tokamak field environment.

Martovetsky, N.N.; Chaplin, M.R.

1995-06-08T23:59:59.000Z

357

? Adjustable Output Voltage  

E-Print Network (OSTI)

The LM25010 features all the functions needed to implement a low cost, efficient, buck regulator capable of supplying in excess of 1A load current. This high voltage regulator integrates an N-Channel Buck Switch, and is available in thermally enhanced LLP-10 and TSSOP-14EP packages. The constant on-time regulation scheme requires no loop compensation resulting in fast load transient response and simplified circuit implementation. The operating frequency remains constant with line and load variations due to the inverse relationship between the input voltage and the on-time. The valley current limit detection is set at 1.25A. Additional features include: VCC under-voltage lock-out, thermal shutdown, gate drive under-voltage lock-out, and maximum duty cycle limiter.

Lmq Is Aec-q Grade

2008-01-01T23:59:59.000Z

358

HIGH VOLTAGE ELECTRODES  

DOE Patents (OSTI)

S>This patent relates to electrode structure for creating an intense direct current electric field which may have a field strength of the order of two to three times that heretofore obtained, with automatic suppression of arcing. The positive electrode is a conventional conductive material such as copper while the negative electrode is made from a special material having a resistivity greater than that of good conductors and less than that of good insulators. When an incipient arc occurs, the moderate resistivity of the negative electrode causes a momentary, localized decrease in the electric field intensity, thus suppressing the flow of electrons and avoiding arcing. Heated glass may be utilized for the negative electrode, since it provides the desired combination of resistivity, capacity, dielectric strength, mechani-cal strength, and thermal stability. (AEC)

Murray, J.J.

1963-04-23T23:59:59.000Z

359

An in depth examination of semi floating gate ultra low voltage flip-flops for high speed applications.  

E-Print Network (OSTI)

??In this thesis 4 different ultra low voltage (ULV) flip-flops are presented. Floating gates has been exploited to significantly increase the drain-source current. This technique… (more)

Simenstad, Erik Jonathan

2013-01-01T23:59:59.000Z

360

Design Techniques for High Speed Low Voltage and Low Power Non-Calibrated Pipeline Analog to Digital Converters  

E-Print Network (OSTI)

The profound digitization of modern microelectronic modules made Analog-to- Digital converters (ADC) key components in many systems. With resolutions up to 14bits and sampling rates in the 100s of MHz, the pipeline ADC is a prime candidate for a wide range of applications such as instrumentation, communications and consumer electronics. However, while past work focused on enhancing the performance of the pipeline ADC from an architectural standpoint, little has been done to individually address its fundamental building blocks. This work aims to achieve the latter by proposing design techniques to improve the performance of these blocks with minimal power consumption in low voltage environments, such that collectively high performance is achieved in the pipeline ADC. Towards this goal, a Recycling Folded Cascode (RFC) amplifier is proposed as an enhancement to the general performance of the conventional folded cascode. Tested in Taiwan Semiconductor Manufacturing Company (TSMC) 0.18?m Complementary Metal Oxide Semiconductor (CMOS) technology, the RFC provides twice the bandwidth, 8-10dB additional gain, more than twice the slew rate and improved noise performance over the conventional folded cascode-all at no additional power or silicon area. The direct auto-zeroing offset cancellation scheme is optimized for low voltage environments using a dual level common mode feedback (CMFB) circuit, and amplifier differential offsets up to 50mV are effectively cancelled. Together with the RFC, the dual level CMFB was used to implement a sample and hold amplifier driving a singleended load of 1.4pF and using only 2.6mA; at 200MS/s better than 9bit linearity is achieved. Finally a power conscious technique is proposed to reduce the kickback noise of dynamic comparators without resorting to the use of pre-amplifiers. When all techniques are collectively used to implement a 1Vpp 10bit 160MS/s pipeline ADC in Semiconductor Manufacturing International Corporation (SMIC) 0.18[mu]m CMOS, 9.2 effective number of bits (ENOB) is achieved with a near Nyquist-rate full scale signal. The ADC uses an area of 1.1mm2 and consumes 42mW in its analog core. Compared to recent state-of-the-art implementations in the 100-200MS/s range, the presented pipeline ADC uses the least power per conversion rated at 0.45pJ/conversion-step.

Assaad, Rida Shawky

2009-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

High-Order Terms in the Asymptotic Expansions of the Steady-State Voltage Potentials in the Presence of Conductivity Inhomogeneities of Small Diameter  

E-Print Network (OSTI)

We derive high-order terms in the asymptotic expansions of the steady-state voltage potentials in the presence of a finite number of diametrically small inhomogeneities with conductivities different from the background conductivity. Our derivation is rigorous, and based on layer potential techniques. The asymptotic expansions in this paper are valid for inhomogeneities with Lipschitz boundaries and those with extreme conductivities.

Habib Ammari; Hyeonbae Kang

2001-12-12T23:59:59.000Z

362

Low-voltage gyrotrons  

SciTech Connect

For a long time, the gyrotrons were primarily developed for electron cyclotron heating and current drive of plasmas in controlled fusion reactors where a multi-megawatt, quasi-continuous millimeter-wave power is required. In addition to this important application, there are other applications (and their number increases with time) which do not require a very high power level, but such issues as the ability to operate at low voltages and have compact devices are very important. For example, gyrotrons are of interest for a dynamic nuclear polarization, which improves the sensitivity of the nuclear magnetic resonance spectroscopy. In this paper, some issues important for operation of gyrotrons driven by low-voltage electron beams are analyzed. An emphasis is made on the efficiency of low-voltage gyrotron operation at the fundamental and higher cyclotron harmonics. These efficiencies calculated with the account for ohmic losses were, first, determined in the framework of the generalized gyrotron theory based on the cold-cavity approximation. Then, more accurate, self-consistent calculations for the fundamental and second harmonic low-voltage sub-THz gyrotron designs were carried out. Results of these calculations are presented and discussed. It is shown that operation of the fundamental and second harmonic gyrotrons with noticeable efficiencies is possible even at voltages as low as 5-10 kV. Even the third harmonic gyrotrons can operate at voltages about 15 kV, albeit with rather low efficiency (1%-2% in the submillimeter wavelength region).

Glyavin, M. Yu.; Zavolskiy, N. A.; Sedov, A. S. [Institute of Applied Physics RAS, N. Novgorod 603600 (Russian Federation); Nusinovich, G. S. [IREAP, University of Maryland, College Park, Maryland 20742-3511 (United States)

2013-03-15T23:59:59.000Z

363

Effect of the change in the load resistance on the high voltage pulse transformer of the intense electron-beam accelerators  

Science Conference Proceedings (OSTI)

A high voltage pulse transformer (HVPT) is usually used as a charging device for the pulse forming line (PFL) of intense electron-beam accelerators (IEBAs). Insulation of the HVPT is one of the important factors that restrict the development of the HVPT. Until now, considerable effort has been focused on minimizing high field regions to avoid insulation breakdown between windings. Characteristics of the HVPT have been widely discussed to achieve these goals, but the effects of the PFL and load resistance on HVPT are usually neglected. In this paper, a HVPT is used as a charging device for the PFL of an IEBA and the effect of the change in the load resistance on the HVPT of the IEBA is presented. When the load resistance does not match the wave impedance of the PFL, a high-frequency bipolar oscillating voltage will occur, and the amplitude of the oscillating voltage will increase with the decrease in the load resistance. The load resistance approximates to zero and the amplitude of the oscillating voltage is much higher. This makes it easier for surface flashover along the insulation materials to form and decrease the lifetime of the HVPT.

Cheng Xinbing; Liu Jinliang; Qian Baoliang; Zhang Yu; Zhang Hongbo [College of Photoelectrical Science and Engineering, National University of Defense Technology, Hunan 410073 (China)

2009-11-15T23:59:59.000Z

364

Thermo-Mechanical Bending Testing and Analysis for Public Service Electric and Gas Company Field-Aged Cables  

Science Conference Proceedings (OSTI)

High-pressure fluid-filled, pipe-type cables have been in operation since the mid-1930s, and they are acknowledged to be very reliable. However, some 230-kV and 345-kV cables, primarily those installed in the 1960s and 1970s, have experienced a failure mechanism known as thermo-mechanical bending (TMB). Cable expansion with an increase in loading causes the cables to form a series of bends. The cables tend to straighten as they cool when loads are reduced. In most cases, this movement can occur daily for...

2009-10-28T23:59:59.000Z

365

Utility Experience of In-Pipe Thermo-Mechanical Bending (TMB) Events on Pipe-Type Cables  

Science Conference Proceedings (OSTI)

High-pressure fluid-filled, pipe-type cables are quite reliable. However, some 230-kV and 345-kV cables, primarily those installed in the 1960s and 1970s, have experienced a failure mechanism known as thermomechanical bending (TMB). Cable expansion with an increase in loading causes the cables to form a series of bends. The cables tend to straighten as they cool when loads are reduced. In most cases, this movement can occur daily for many decades without incident. In some cases, however, this TMB motion ...

2008-12-11T23:59:59.000Z

366

Field Demonstration of a 24-kV Superconducting Cable at Detroit Edison: Final Report  

Science Conference Proceedings (OSTI)

Following up the successful testing of a complete 50 m, 115 kV high temperature superconducting (HTS) power cable system prototype, EPRI, Pirelli Power Cables and Systems, the Department of Energy, Detroit Edison, and American Superconductor Corporation undertook a project to design, install, and operate a 24 kV HTS power cable at Detroit Edison's Frisbie substation to serve customer load. The demonstration cable circuit ran approximately 120 m between the 24 kV bus distribution bus and a 120 kV-24 kV tr...

2004-12-22T23:59:59.000Z

367

Experimental and theoretical studies of a high temperature cesium-barium tacitron, with application to low voltage-high current inversion. Final report, April 1, 1993--February 28, 1994  

SciTech Connect

A low voltage/high current switch refer-red as ``Cs-Ba tacitron`` is studied for use as a dc to ac inverter in high temperature and/or ionizing radiation environments. The operational characteristics of the Cs-Ba tacitron as a switch were investigated experimentally in three modes: (a) breakdown mode, (b) I-V mode, and (c) current modulation mode. Operation parameters measured include switching frequencies up to 20 kHz, hold-off voltages up to 200 V, current densities in excess of 15 A/CM{sup 2}, switch power density of 1 kW/cm{sup 2}, and a switching efficiency in excess of 90 % at collector voltages greater than 30 V. Also, if the discharge current is circuit limited to a value below the maximum thermal emission current density, the voltage drop is constant and below 3 V.

Murray, C.S.; El-Genk, M.S.

1994-02-01T23:59:59.000Z

368

Program on Technology Innovation: Grain Growth in Lead Alloy Sheathing and Its Influence on the Life of Lead-Sheathed Power Cables  

Science Conference Proceedings (OSTI)

Urban electric utilities installed large quantities of paper-insulated, lead-covered (PILC) power cable for medium-voltage distribution until about 50 years ago. Lead grain growth and re-crystallization occur with the aging of the lead sheaths of these cables and are known to affect cable sheath life. This report describes re-crystallization and grain growth in lead and lead alloys, emphasizing cable-sheath alloys used in North America and how grain size influences tensile, fatigue, and creep properties ...

2007-05-31T23:59:59.000Z

369

Cable Polymer Aging and Condition Monitoring Research at Sandia National Laboratories Under the Nuclear Energy Plant Optimization (NEPO) Program  

Science Conference Proceedings (OSTI)

This report describes cable polymer aging and condition monitoring research performed at Sandia National Laboratories under the Nuclear Energy Plant Optimization (NEPO) Program from 2000 to 2005. The research results apply to low-voltage cable insulation and jacket materials that are commonly used in U.S. nuclear power plants. The research builds upon and is linked to research performed at Sandia from 1977 through 1986, sponsored by the U.S. Nuclear Regulatory Commission. Aged and unaged specimens from t...

2005-12-20T23:59:59.000Z

370

NIST Debuts Superconducting Quantum Computing Cable  

Science Conference Proceedings (OSTI)

... electronic vibrations on a microfabricated aluminum cable, demonstrating a new component for potential ultra-powerful quantum computers of the ...

2013-07-08T23:59:59.000Z

371

Measurements of AC Losses and Current Distribution in Superconducting Cables  

Science Conference Proceedings (OSTI)

This paper presents our new experimental facility and techniques to measure ac loss and current distribution between the layers for High Temperature Superconducting (HTS) cables. The facility is powered with a 45 kVA three-phase power supply which can provide three-phase currents up to 5 kA per phase via high current transformers. The system is suitable for measurements at any frequency between 20 and 500 Hz to better understand the ac loss mechanisms in HTS cables. In this paper, we will report techniques and results for ac loss measurements carried out on several HTS cables with and without an HTS shielding layer. For cables without a shielding layer, care must be taken to control the effect of the magnetic fields from return currents on loss measurements. The waveform of the axial magnetic field was also measured by a small pick-up coil placed inside a two-layer cable. The temporal current distribution between the layers can be calculated from the waveform of the axial field.

Nguyen, Doan A [Los Alamos National Laboratory (LANL); Ashworth, Stephen P [Los Alamos National Laboratory (LANL); Duckworth, Robert C [ORNL; Carter, Bill [AMSC; Fleshler, Steven [AMER Superconductor Corp, Devens, MA 01434

2011-01-01T23:59:59.000Z

372

Multiple connection for an undersea cable system  

Science Conference Proceedings (OSTI)

A multiple connection is claimed for connecting a plurality of armored cables to the housing of electrical apparatus in an undersea system having a cable interconnection point where a plurality of cables serving different destinations are brought together. Each of these cables comprise a core surrounded by armor and are terminated by a length of bared core extending beyond a severed end of the armor. The housing has a hollow cable-fixing part through which the bared cable cores pass, characterized in that said connection comprises: a steel binding ring through which the armored portion of each of said cables, is threaded, said ring serving to bind said armored portions of cable together; a steel tube threaded over said bared cores of said cables, having one end abutting against severed end portions of the armor of said cables and having its other end fixed mechanically to said hollow cable-fixing part of the electrical apparatus housing; and auxiliary armor wound around the portions of armored cable bound together by said ring and around the adjacent portion of said steel tube.

Guazzo, L.; Trezeguet, J.P.

1984-05-08T23:59:59.000Z

373

Increased Power Flow Guidebook - Underground Cables  

Science Conference Proceedings (OSTI)

Utilities must consider a number of factors when evaluating uprating and upgrading options for underground transmission cables. This comprehensive guidebook documents the state-of-science for increasing power flow capacities of underground transmission cables. It provides an overview of underground transmission cable ratings and uprating techniques so that the maximum utilization can be obtained from the existing underground transmission infrastructure.

2003-12-01T23:59:59.000Z

374

Voltage controlled current source  

DOE Patents (OSTI)

A seven decade, voltage controlled current source is described for use in testing intermediate range nuclear instruments that covers the entire test current range of from 10 picoamperes to 100 microamperes. High accuracy is obtained throughout the entire seven decades of output current with circuitry that includes a coordinated switching scheme responsive to the input signal from a hybrid computer to control the input voltage to an antilog amplifier, and to selectively connect a resistance to the antilog amplifier output to provide a continuous output current source as a function of a preset range of input voltage. An operator controlled switch provides current adjustment for operation in either a real-time simulation test mode or a time response test mode.

Casne, Gregory M. (Pittsburgh, PA)

1992-01-01T23:59:59.000Z

375

HIGH VOLTAGE TERMINAL IN COSY ELECTRON COOLER V.A. Chekavinskiy, E.A. Bekhtenev, I.A. Gusev, M.N. Kondaurov, V.R. Kozak, E.A. Kuper, V.R.  

E-Print Network (OSTI)

, and powered by multistage transformer, capable of 15 kW power at 26 kHz. Wireless control is passed through high voltage circumstances. Powering of HVT electronics is provided by cascade transformer acceleration system ­ high voltage terminal. All power and control electronics were placed in a single isolated

Kozak, Victor R.

376

Intrinsic Surface Stability in LiMn2-xNix04-s (x = 0.45, 0.5) High Voltage Spinel Materials for Lithium Ion Batteries  

DOE Green Energy (OSTI)

This work reports the surface stability of the high voltage Li ion cathode LiMn{sub 2–x}Ni{sub x}O{sub 4–?} (x = 0.5, 0.45) by comparing thin film and powder composite electrodes after cycling using X-ray photoelectron spectroscopy. The thin film electrodes offer the ability to probe the surface of the material without the need of a conductive agent and polymer binder typically used in composite electrodes. The results suggest that neither oxidation of PF{sub 6} to POF{sub 3} nor the decomposition of ethylene carbonate or dimethylene carbonate occurs on the surface of the spinel material. These results confirm the enhanced cycling stability and rate capability associated with the high voltage spinel material and suggests that the SEI layer forms due to the reaction of electrochemically inactive components in composite electrodes with the electrolyte.

Carroll, Kyler J.; Yang, Ming-Che; Veith, G. M.; Dudney, N. J.; Meng, Ying Shirley

2012-01-01T23:59:59.000Z

377

Voltage balanced multilevel voltage source converter system  

SciTech Connect

A voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means.

Peng, Fang Zheng (Oak Ridge, TN); Lai, Jih-Sheng (Knoxville, TN)

1997-01-01T23:59:59.000Z

378

Voltage balanced multilevel voltage source converter system  

SciTech Connect

Disclosed is a voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means. 15 figs.

Peng, F.Z.; Lai, J.S.

1997-07-01T23:59:59.000Z

379

Decision support system for estimating the technically and economically exploitable renewable energy sources potential in wide areas for connection to high voltage networks  

Science Conference Proceedings (OSTI)

A decision support information system for estimating the technically and economically exploitable renewable energy sources (RES) potential in wide areas is presented in this paper. The system estimates the RES potential in specific areas, examines ... Keywords: DSS, GIS, biomass, decision support systeoms, distributed generation, geographical information systems, high voltage network, renewable energy estimation, renewable energy forecasting, renewable energy potential, renewable energy sources, small hydro, wind energy, wind power

Michael Psalidas; Demosthenes Agoris; Vassilis Kilias; Kostas Tigas; Panagiotis Stratis; Giannis Vlachos

2005-04-01T23:59:59.000Z

380

Feasibility Study for the Development of High-Voltage, Low-Current Power Semiconductor Devices: 2003 Strategic Science and Technolog y Project  

Science Conference Proceedings (OSTI)

The intelligent universal transformer (IUT) will be an advanced power-electronics replacement for conventional distribution transformers that adds significant new functional capabilities to those available from conventional copper and iron transformers. This report assesses the state of the art and development options for obtaining high-voltage, low-current power semiconductors (both switches and diodes) needed in the circuit topology being developed for the IUT.

2004-03-29T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Impact of High-Penetration PV on Distribution System Performance: Assessment of Regulation Control Options for Voltage Mitigation  

Science Conference Proceedings (OSTI)

Photovoltaics are beginning to challenge distribution system power engineers nationwide. The impact photovoltaics (PV) has on the power system is directly tied to system characteristics which include but are not limited to voltage class, load, regulation, and short circuit capacity. In addition to the system characteristics, the solar characteristics also play a key role. These include details on the PV systems themselves in addition to the solar irradiance data. The correlation of PV output and ...

2012-12-31T23:59:59.000Z

382

Condition Assessment Techniques for Laminar Dielectric Transmission Cable Systems  

Science Conference Proceedings (OSTI)

As aging and higher circuit loadings lead to increased failures of pipe-type cable systems, utilities need effective techniques for assessing the key components of these systems. Many off-line and on-line diagnostic and assessment techniques are in use to inspect the condition of laminar dielectric cable systems. However, because of the high labor costs and required circuit outage of off-line testing, much of the current research and development focuses on methods of on-line monitoring. A number of mecha...

2010-12-23T23:59:59.000Z

383

Field Demonstration of a 24-kV Superconducting Cable at Detroit Edison  

SciTech Connect

Customer acceptance of high temperature superconducting (HTS) cable technology requires a substantial field demonstration illustrating both the system's technical capabilities and its suitability for installation and operation within the utility environment. In this project, the world's first underground installation of an HTS cable using existing ductwork, a 120 meter demonstration cable circuit was designed and installed between the 24 kV bus distribution bus and a 120 kV-24 kV transformer at Detroit Edison's Frisbie substation. The system incorporated cables, accessories, a refrigeration system, and control instrumentation. Although the system was never put in operation because of problems with leaks in the cryostat, the project significantly advanced the state-of-the-art in the design and implementation of Warm Dielectric cable systems in substation applications. Lessons learned in this project are already being incorporated in several ongoing demonstration projects.

Kelley, Nathan; Corsaro, Pietro

2004-12-01T23:59:59.000Z

384

Cell Voltage Noise Reduction Based on Wavelet in Aluminum ...  

Science Conference Proceedings (OSTI)

Presentation Title, Cell Voltage Noise Reduction Based on Wavelet in Aluminum ... cell voltage signals collected in aluminium electrolysis process are with high ...

385

Dynamic Simulation of Cell Voltage Resonance Effect in Aluminum ...  

Science Conference Proceedings (OSTI)

Dubal Cell Voltage Drop Initiatives towards Low Energy High Amperage Cells · Dynamic Simulation of Cell Voltage Resonance Effect in Aluminum Electrolysis ...

386

Field Demonstration of a 24-KV Warm Dielectric Cable at Detroit Edison: FY2001 Annual Progress Report  

Science Conference Proceedings (OSTI)

A project sponsored by EPRI, Pirelli Power Cables and Systems, the U.S. Department of Energy, Detroit Edison, and American Superconductor Corporation was initiated in 1998 to install and operate a 24 kV high-temperature superconducting (HTS) power cable in a Detroit Edison substation to serve customer load. The scope of this demonstration will result in the world's first underground installation of an HTS cable system using an existing duct network. Furthermore, the project involves installing the necess...

2002-02-12T23:59:59.000Z

387

Improved Conventional Testing of Power Plant Cables  

Science Conference Proceedings (OSTI)

Factors such as mechanical stress, dust and pollution accumulation, moisture, and thermal aging can cause deterioration and ultimately failure of power, control, and instrumentation cables. This report documents physical, chemical, and electrical tests performed on thermally aged power plant cable, with emphasis on improvements in two major electrical diagnostic techniques: low-frequency insulation analysis to probe the bulk condition of cable insulation and partial discharge testing to detect cracks and...

1996-03-14T23:59:59.000Z

388

Fastbus cable segment extender based on TTL  

Science Conference Proceedings (OSTI)

A method to drive a FASTBUS cable segment over long distance is described. The signal level transmitted is converted from standard FASTBUS cable segment signal to a TTL differential output; the scheme increases noise immunity. In addition, the receiver has a wide tolerance of common mode range of +/-15 V. By applying a deskewing mechanism in the extender module, we have achieved more than 10/sup 10/ transactions of FASTBUS without any error with a cable length of 100 m.

Ikeda, H.; Yamauchi, M.

1986-10-01T23:59:59.000Z

389

Cable Pushing and Calculation of Pulling Tensions for Distribution and Transmission Cables  

Science Conference Proceedings (OSTI)

Traditional techniques for the installation of cable into conduit systems require pulling the cable with a rope attached to the leading end. EPRI has demonstrated that cable pushing can significantly reduce pulling forces, allow longer cable lengths to be pulled safely, and reduce the number of manholes and splices in a circuit. These benefits can result in direct savings for the utility and increased reliability for the customer.

1997-01-06T23:59:59.000Z

390

High voltage, fast turn-on and turn-off switch: Final report for period September 2, 1998 - March 17, 1999  

DOE Green Energy (OSTI)

The aspect to be investigated during this contract was an electron-beam triggered diamond switch to be used in high power modulators. Today's high power modulators require higher voltage switches than those developed to date. Specifically, the proposed 1 TeV linear collider, the NLC/ILC at the Stanford Linear Accelerator Center (SLAC), consists of two linacs with 6600 X-Band klystrons powered by 3300 high power modulators. These modulators require switches capable of handling 80 kV, switching 8 kA with pulse durations ranging from 2 ps (linac) to 6 {micro}s (pre-linac) with switching times <50 ns at pulse repetition frequencies up to 180 Hz. In addition the large number of switches and other components dictate a pulse to pulse jitter of <10 ns and a mean time between failures of at least 50,000 hours. The present approach is to use hydrogen filled thyratrons. While these switches meet the voltage and conduction current requirements they lack the required reliability (pulse to pulse jitter) and lifetime. Research to improve these aspects is in progress. A solid state switch inherently offers the required reliability and lifetime. However, Si-based switches developed to date are limited to about 5 kV and several must be stacked in series to deliver the required voltage. This further increases the already large parts count and compromises reliability and lifetime. A monolithic, solid state switch capable of meeting all the requirements for X-Band modulators would be ideal. DOE selected this proposal for a Phase 1 SBIR award and this final report describes the progress made during the contract.

Jochen Schein; Xiaoxi Xu; Niansheng Qi; Steven Gensler; Rahul Prasad; Mahadevan Krishnan

1999-04-10T23:59:59.000Z

391

Digital Cable Goes Quantum: NIST Debuts Superconducting ...  

Science Conference Proceedings (OSTI)

... The setup resembles a miniature version of a cable-television transmission line, but with some powerful added features, including superconducting ...

2012-06-08T23:59:59.000Z

392

PQ Encyclopedia: Understanding Voltage Unbalance  

Science Conference Proceedings (OSTI)

This PQ Encyclopedia examines voltage unbalance, methods to calculate line voltages and the degree of voltage unbalance, and mitigation techniques.

2009-12-11T23:59:59.000Z

393

Efficient cable arrangement in cable stayed bridges based on sensitivity analysis of aeroelastic behaviour  

Science Conference Proceedings (OSTI)

Construction of cable supported bridges has experienced a great impulse in the past decade. Bridges having more than 800m of span length were built in France and Japan and some bridges with span length of more than 1km are going to be built, such as ... Keywords: Aeroelastic analysis, Cable configuration, Cable stayed bridges, Efficient structural design, Sensitivity analysis

José Á. Jurado; Félix Nieto; Santiago Hernández; Alejandro Mosquera

2008-09-01T23:59:59.000Z

394

Design, Construction, and Test Results for Three Different Fiber Optic Tow Cables  

Science Conference Proceedings (OSTI)

The design, manufacture, and testing of three armored fiber optic tow cables is discussed. The motivation for these developments was the technical need to have low-loss high-bandwidth transmission lines, that function with negligible crosstalk and absence ...

E. Althouse

2006-09-01T23:59:59.000Z

395

Cooling Configuration Design Considerations for Long-Length HTS Cables  

SciTech Connect

Recent successes in demonstrating high temperature superconducting (HTS) cable systems hundreds of meters in length have inspired even longer length projects. A compact and energy efficient cooling configuration can be achieved using a counterflow-cooling arrangement. This is particularly attractive when all three phases are contained in a single cryostat because of the elimination of the space and thermal requirements of a separate liquid nitrogen return line. Future cable projects will utilize second generation (2G) wire which is expected to become lower in cost but may have different thermal requirements than first generation (1G) BSCCO wire due to the lower critical temperature and to a lesser extent, the lower thermal conductivity of the wire. HTS cable configurations will be studied with a numerical model to assess thermal hydraulic performance with AC and thermal losses; a summary of the results from the analysis will be presented. An analysis of the cable thermal- hydraulic response to over-current faults will be presented.

Demko, Jonathan A [ORNL; Duckworth, Robert C [ORNL

2009-01-01T23:59:59.000Z

396

Modeling and simulation of power cable insulation  

Science Conference Proceedings (OSTI)

The use of power cables for transmission and distribution of electrical power have increased since the advent of suitable, reliable and economical polymeric insulating material; such as cross-linked polyethylene (XLPE). Power cables plays crucial role ... Keywords: cross-linked polyethylene (XLPE), imperfect insulation, local defects, lossy insulation, partial discharge (PD)

K. D. Patil; A. A. Bhole; W. Z. Gandhare

2010-02-01T23:59:59.000Z

397

An Internal Coaxil Cable Seal System  

DOE Patents (OSTI)

The invention is a seal system for a coaxial cable more specifically an internal seal system placed within the coaxial cable and its constituent components. A series of seal stacks including flexible rigid rings and elastomeric rings are placed on load bearing members within the coaxial cable. The current invention is adapted to seal the annular space between the coaxial cable and an electrical contact passing there through. The coaxial cable is disposed within drilling components to transmit electrical signals between drilling components within a drill string. During oil and gas exploration, a drill string can see a range of pressures and temperatures thus resulting in multiple combinations of temperature and pressure and increasing the difficulty of creating a robust seal for all combinations. The seal system can be used in a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David (Lehi, UT); Dahlgren, Scott (Provo, UT); Sneddon, Cameron (Provo, UT); Briscoe, Michael (Lehi, UT); Fox, Joe (Spanish Fork, UT)

2004-12-23T23:59:59.000Z

398

Underwater splice for submarine coaxial cable  

SciTech Connect

The invention is a device for splicing submarine coaxial cable underwater on the seafloor with a simple push-on operation to restore and maintain electrical and mechanical strength integrity; the splice device is mateable directly with the severed ends of a coaxial cable to be repaired. Splicing assemblies comprise a dielectric pressure compensating fluid filled guide cavity, a gelled castor oil cap and wiping seals for exclusion of seawater, electrical contacts, a cable strength restoration mechanism, and a pressure compensation system for controlled extrusion of and depletion loss prevention of dielectric seal fluid during cable splicing. A splice is made underwater by directly inserting prepared ends of coaxial cable, having no connector attachments, into splicing assemblies.

Inouye, A.T.; Roe, T. Jr.; Tausing, W.R.; Wilson, J.V.

1984-10-30T23:59:59.000Z

399

Methods for Cleaning and Evaluating Pipe-Type Cable Pipes for Retrofit with Extruded Dielectric Cable Systems  

Science Conference Proceedings (OSTI)

This report summarizes studies of pipe cleaning, "pigging," inspecting, and testing pipe-type cable pipes for re-conditioning as conduits compatible with extruded dielectric cables.

2001-12-12T23:59:59.000Z

400

Enhancing Open Circuit Voltage by Combining Thermoelectric ...  

Science Conference Proceedings (OSTI)

Enhancing Open Circuit Voltage by Combining Thermoelectric Materials and Dye -Sensitized Solar Cell in Series · Estimation of Compressive Strength of High ...

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Building and Fire Publications  

Science Conference Proceedings (OSTI)

... Laboratory test data are presented on high voltage breakdown values for armored cable (type AC cable), nonmetallic-sheated cable (type NM), flat ...

402

Mitigation of different type voltage sags in low voltage distribution systems using dynamic voltage restorer  

Science Conference Proceedings (OSTI)

The main problems of the voltage sag in low voltage distribution systems due to sensitive loads. Voltage sags can caused malfunction in the distribution system. In order to protect voltage sags in the network a device which called Dynamic Voltage Restorer ... Keywords: custom device, dynamic voltage restorer (DVR), low voltage, power injected, voltage sag

Rosli Omar

2010-03-01T23:59:59.000Z

403

Tool for cutting insulation from electrical cables  

DOE Patents (OSTI)

This invention is an efficient hand tool for precisely slitting the sheath of insulation on an electrical cable--e.g., a cable two inches in diameter--in a manner facilitating subsequent peeling or stripping of the insulation. The tool includes a rigid frame which is slidably fitted on an end section of the cable. The frame carries a rigidly affixed handle and an opposed, elongated blade-and-handle assembly. The blade-and-handle assembly is pivotally supported by a bracket which is slidably mounted on the frame for movement toward and away from the cable, thus providing an adjustment for the depth of cut. The blade-and-handle assembly is mountable to the bracket in two pivotable positions. With the assembly mounted in the first position, the tool is turned about the cable to slit the insulation circumferentially. With the assembly mounted in the second position, the tool is drawn along the cable to slit the insulation axially. When cut both circumferentially and axially, the insulation can easily be peeled from the cable.

Harless, Charles E. (Metropolis, IL); Taylor, Ward G. (Vienna, IL)

1978-01-01T23:59:59.000Z

404

RECIPIENT:Princeton Power Systems STATE: NJ PROJECT Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Princeton Power Systems Princeton Power Systems STATE: NJ PROJECT Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage TITLE: Funding Opportunity Announcement Number Procurement Instrument Number NEPA Control Number cm Number DE-FOA-0000293 DE-EE0003640 GFO-000364~001 GOO Based on my review of the information concerning the proposed action, as NEPA Compliance Officer (authorized under DOE Order 451.1A), I have made the foUowing determination: CX, EA, EIS APPENDIX AND NUMBER: Description: A9 Information gathering (including, but not limited to, ~terature surveys, inventories, audits), data analysis (including computer modeling), document preparation (such as conceptual design or feasibility studies, analytical energy supply

405

Development of spherical-trailer-type cable reel mechanism  

Science Conference Proceedings (OSTI)

Cabled communication is considered to be more useful than wireless communication for rescue robots used in post-disaster environments. The cable can not only provide good signal communication but also contribute to assist to retrieve the robot. However, ... Keywords: cable oscillating movement, cable reel mechanism, rescue-robot, spatial cam, spherical trailer

Masayuki Arai; Shigeo Hirose

2007-08-01T23:59:59.000Z

406

Automatic voltage imbalance detector  

DOE Patents (OSTI)

A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

Bobbett, Ronald E. (Los Alamos, NM); McCormick, J. Byron (Los Alamos, NM); Kerwin, William J. (Tucson, AZ)

1984-01-01T23:59:59.000Z

407

Constant voltage ultracapacitor  

Science Conference Proceedings (OSTI)

Ultracapacitors have attracted lots of attention recently due to their growing use in hybrid vehicles and in energy storage applications for the smart grid. A very undesirable feature of ultracapacitors is the fact that the voltage drops as the capacitor is discharged. DC-DC converters are employed at present to convert the voltage of the ultracapacitor to constant voltage; however

Ezzat G. Bakhoum

2012-01-01T23:59:59.000Z

408

Vids4Grids: Smart Meters and Super Cables | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Grids: Smart Meters and Super Cables Grids: Smart Meters and Super Cables Vids4Grids: Smart Meters and Super Cables March 14, 2011 - 4:46pm Addthis This episode of Vids 4 Grids will take us to Itron's smart meter factory in West Union, SC where we will learn the role smart meters play in the Smart Grid. Deborah J. Buterbaugh Energy Project Specialist at National Energy Technology Laboratory What does this mean for me? Smart meters allow consumers to get real time information about their energy usage. Super cables help provide more reliable electricity to your home. In January we introduced you to the Vids4Grids project, a series of videos targeting students in high school and starting college. Through integration into curricula and online posting for open viewing, the project aims to increase awareness and create interest in power systems careers to help

409

Vids4Grids: Smart Meters and Super Cables | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Vids4Grids: Smart Meters and Super Cables Vids4Grids: Smart Meters and Super Cables Vids4Grids: Smart Meters and Super Cables March 14, 2011 - 4:46pm Addthis This episode of Vids 4 Grids will take us to Itron's smart meter factory in West Union, SC where we will learn the role smart meters play in the Smart Grid. Deborah J. Buterbaugh Energy Project Specialist at National Energy Technology Laboratory What does this mean for me? Smart meters allow consumers to get real time information about their energy usage. Super cables help provide more reliable electricity to your home. In January we introduced you to the Vids4Grids project, a series of videos targeting students in high school and starting college. Through integration into curricula and online posting for open viewing, the project aims to increase awareness and create interest in power systems careers to help

410

Condition Monitoring of Cables Task 3 Report: Condition Monitoring Techniques for Electric Cables  

SciTech Connect

For more than 20 years the NRC has sponsored research studying electric cable aging degradation, condition monitoring, and environmental qualification testing practices for electric cables used in nuclear power plants. This report summarizes several of the most effective and commonly used condition monitoring techniques available to detect damage and measure the extent of degradation in electric cable insulation. The technical basis for each technique is summarized, along with its application, trendability of test data, ease of performing the technique, advantages and limitations, and the usefulness of the test results to characterize and assess the condition of electric cables.

Villaran, M.; Lofaro, R.; na

2009-11-30T23:59:59.000Z

411

High voltage research (breakdown strengths of gaseous and liquid insulators). Semiannual report, April 1--September 30, 1977  

DOE Green Energy (OSTI)

Direct current breakdown strength measurements on a large number of multicomponent gas mixtures at low (approximately less than 1 atm) and high (approximately less than 5 atm) pressures led to the discovery of many gas mixtures of electron-attaching gases and strongly electron-attaching gases with N/sub 2/ and C/sub 3/F/sub 8/ which are superior to SF/sub 6/. Of special significance are mixtures containing C/sub 4/F/sub 6/ (perfluoro-2-butyne). The breakdown strength of one such mixture (20 percent C/sub 4/F/sub 6/ to 80 percent SF/sub 6/) is approximately 30 percent higher than pure SF/sub 6/ under identical conditions, both at low (approximately 0.7 atm) and high (4.6 atm) pressures. Perfluorocyclohexene (C/sub 6/F/sub 10/) and C/sub 5/F/sub 8/ (perfluorocyclopentene) were found at low pressure (approximately 0.2 atm) to be, respectively, approximately 2.1 and 2.2 times better than SF/sub 6/ under comparable conditions; they both have a potential as additives in gas mixtures. The effect of the inelastic electron scattering properties of a gas via negative ion resonances in the low-energy range (1 to approximately 4 eV) on the breakdown strength has been demonstrated for H/sub 2/, N/sub 2/, and CO and binary mixtures of these with SF/sub 6/ and C/sub 4/F/sub 6/ (perfluoro-2-butyne). The construction of a new high pressure (to approximately 11 atm), variable temperature (-50/sup 0/C to + 150/sup 0/C) apparatus has been completed and a practical test facility utilizing cylindrical electrode geometries has been put into operation; the first results on the latter apparatus were on SF/sub 6/-N/sub 2/ and c-C/sub 4/F/sub 8/--N/sub 2/ mixtures. Studies of environmental effects of dielectric gases via their electron-impact-induced decompositions and analysis of their breakdown products have begun using mass spectrometry and gas chromatography; C/sub 4/F/sub 6/ (perfluoro-2-butyne) seems to be resistant to electron-impact-induced decomposition indicating long-term stability.

Christophorou, L. G.; James, D. R.; Pai, R. Y.; Mathis, R. A.; Pace, M. O.; Bouldin, D. W.; Christodoulides, A. A.; Chan, C. C.

1977-11-01T23:59:59.000Z

412

The correlation of the electrical properties with electron irradiation and constant voltage stress for MIS devices based on high-k double layer (HfTiSiO: N and HfTiO:N) dielectrics  

Science Conference Proceedings (OSTI)

This paper describes the influence of e-beam irradiation and constant voltage stress on the electrical characteristics of metal-insulator-semiconductor structures, with double layer high-k dielectric stacks containing HfTiSiO:N and HfTiO:N ultra-thin ... Keywords: Electrical properties, High-k dielectrics, Metal-insulator-semiconductor (MIS) devices

V. Mikhelashvili; P. Thangadurai; W. D. Kaplan; G. Eisenstein

2010-11-01T23:59:59.000Z

413

Plant Engineering: Results of Cable Rejuvenation of Severely Degraded Black Ethylene Propylene Rubber Medium-Voltage Cables  

Science Conference Proceedings (OSTI)

This report describes the evaluation of the effects of commercially available rejuvenation on black ethylene propylene rubber (EPR) insulation. Black EPR is one of the main insulation types used in power plants built in the late 1960s to mid-1970s. Diagnostic testing and failure mechanism research performed by the Electric Power Research Institute (EPRI) have shown that this insulation, when exposed to wet or submerged conditions, can degrade to the point at which reliability concerns would require ...

2013-06-11T23:59:59.000Z

414

A 4000-A HVDC (high-voltage direct-current) circuit breaker with fast fault-clearing capability: Final report  

Science Conference Proceedings (OSTI)

This project is a follow-up of the first development of a 500 kV HVDC airblast circuit breaker (EPRI project 1507-3). The objective was to increase the current interrupting capability from 2200 A to 4000 A and shorten its fault clearing time. A high current 500 kV HVDC circuit breaker has been built using the passive commutation circuit. The breaker is modular in construction and can be designed for a wide variety of system conditions. More than 400 current interruptions were carried out successfully. Tests have shown that this circuit breaker is capable of interrupting more than 4000 A dc. Practical breakers with current interrupting capability of even 5500 A dc could be built. The circuit breaker operation and the fault-clearing process can be materially speeded up if the trip signal is given as soon as the fault is detected and without waiting for the current levels to come down in response to converter control action. The new dc breakers are shown to be capable of withstanding these transient arc currents of 8000 A without affecting its ability to interrupt the direct current that follows the transient. This transient current withstand capability is greater than is likely to occur during dc faults. The fault clearing time of this HVDC circuit breaker is comparable to the fault clearing time of conventional ac breakers for ac faults. The developed HVDC circuit breaker is now commercially available and can be supplied for use in HVDC systems. Its use in such systems is expected to provide flexibility in system design and contribute to system stability. 38 refs., 52 figs., 9 tabs.

Not Available

1988-04-01T23:59:59.000Z

415

Flashover Characteristics Along the Epoxy Resin Insulator under DC Voltage in SF6 Gas  

Science Conference Proceedings (OSTI)

In order to promote the flexibility about the selection of transmission corridor, DC gas insulated transmission line (GIL) can be utilized to substitute part of the overhead line or cable in special environment. Key factors that greatly threaten the ... Keywords: surface charge accumulation, flashover voltage, surface conductivity, time constant, electric field distribution, geometry

Zhijie Jia; Ping Liu; Jianming Li; Lin Yang

2012-03-01T23:59:59.000Z

416

Use of Hysol US0009 polyurethane encapsulant in battery cables  

DOE Green Energy (OSTI)

This report describes the evaluation of Hysol US0009 polyurethane as an encapsulant for the battery cable used on the MC1605B. The Hysol resin was selected for the application because it was reacted with a non-carcinogenic curing agent and because it exhibited superior mechanical, electrical, and hydrolytic properties over a wide temperature range. The Hysol encapsulant was evaluated to determine if it was superior to the EN-7 elastomer as a sealant against electrolyte migration to the interior of the cable. Environmental tests reported here showed the Hysol was marginal when no preseal was employed but was 100 percent effective when a bird-cage seal was used inside the EMR hardware. The EN-7 encapsulant, on the other hand, was effective only when seals were employed both inside the EMR hardware and at the lug terminations. Without the two preseals, the EN-7 compound was always unsatisfactory. Twenty development battery cables fabricated with Hysol under production operations were tested after alternate immersion in battery electrolyte and after exposures to temperature shock and the MIL-STD 202 environment. Presealed cables successfully survived these exposures and retained their initial DC resistance, insulation resistance, and high potential properties with only minor changes. The environmental tests conducted with these assemblies probably represented five or more years of in-field service. Comparative peel tests demonstrated that the Hysol/neoprene insert bond was twice (5.2 versus 2.8 kg/cm) that of the EN-7 polyurethane. Hysol US0009 has a potential for encapsulation of other WR components and assemblies in which the EN-7 resin has exhibited thermal shortcomings. 7 figures, 10 tables.

Voida, G.

1977-04-01T23:59:59.000Z

417

Temperature Fitting Method Predicting Equidistant Voltage Drop of ...  

Science Conference Proceedings (OSTI)

High Temperature Compression Test to Determine the Anode Paste ... Temperature Fitting Method Predicting Equidistant Voltage Drop of Anode Nod in  ...

418

Automated Voltage Control in LHCb  

E-Print Network (OSTI)

LHCb is one of the 4 LHC experiments. In order to ensure the safety of the detector and to maximize efficiency, LHCb needs to coordinate its own operations, in particular the voltage configuration of the different subdetectors, according to the accelerator status. A control software has been developed for this purpose, based on the Finite State Machine toolkit and the SCADA system used for control throughout LHCb (and the other LHC experiments). This software permits to efficiently drive both the Low Voltage (LV) and High Voltage (HV) systems of the 10 different sub-detectors that constitute LHCb, setting each sub-system to the required voltage (easily configurable at run-time) based on the accelerator state. The control software is also responsible for monitoring the state of the Sub-detector voltages and adding it to the event data in the form of status-bits. Safe and yet flexible operation of the LHCb detector has been obtained and automatic actions, triggered by the state changes of the ...

Granado Cardoso, L; Jacobsson, R

2011-01-01T23:59:59.000Z

419

Substation voltage upgrading  

SciTech Connect

This report addresses specific issues to support sound yet not unduly conservative uprating practices for substations. The main parts of the report cover the insulation withstand and overvoltage protection aspects, environmental measurements, reliability criteria, and industry experience. First the insulation design concerns are addressed. Substation stress by a backflashover of the line insulation due to lightning in the vicinity of the substation is recognized as a critical stress. A representative part of a 550 kV BIL substation was erected at the EPRI High Voltage Transmission Research Center, where also a special test circuit was assembled to produce a fast front, slow tail (0.2/200 {mu}s) wave. The substation as well as some special configurations were tested for line-to-ground and line-to-line withstand. Computer studies were performed to complement the test results. A number of important conclusions was reached. The most prominent result in that the high frequency oscillations, as caused by reflections within the substation, do not effect the Critical Flashover Voltage (CFO). The present practice, based on the highest peak is therefore very conservative. The slow tail of the wave appears to dictate the CFO. An arrester model for computer studies to represent very fast as well as slow phenomena was derived. It is based on full scale arrester test data, made available in this project. The computer program to calculate arrester model parameters is also a part of the report. The electric environmental measurements are reported for the tested substation at the HVTRC and for the uprated substation of Public Service Company of Colorado, both before and after the uprating. The performance is satisfactory when corona free hardware is used. Insulation design criteria are analyzed based on substation reliability, the system viewpoint and consequences of the failure. Utility experience with uprated substations is reviewed.

Panek, J.; Elahi, H.; Lux, A.; Imece, A.F. (General Electric Co., Schenectady, NY (United States). Power Systems Engineering Dept.); LaPanse, R.A.; Stewart, J.R. (Public Service Co. of Colorado, Denver, CO (United States))

1992-04-01T23:59:59.000Z

420

A voltage controlled current source  

DOE Patents (OSTI)

A seven decade, voltage controlled current source is described for use in testing intermediate range nuclear instruments that covers the entire test current range of from 10 picoampers to 100 microamperes. High accuracy is obtained throughout the entire seven decades of output current with circuitry that includes a coordinated switching scheme responsive to the input signal from a hybrid computer to control the input voltage to an antilog amplifier, and to selectively connect a resistance to the antilog amplifier output to provide a continuous output current source as a function of a preset range of input voltage. An operator controlled switch provides current adjustment for operation in either a real-time simulation test mode or a time response test mode.

Casne, G.M.

1990-12-21T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

High-Voltage Impulse Testers  

Science Conference Proceedings (OSTI)

... The objective of this test circuit is to super- impose on a ... pulse is coupled across inductance L by the coupling capacitor Ca. ... P lastic Capacitors, Inc. ...

2013-05-17T23:59:59.000Z

422

Automated Voltage Standard Ready  

Science Conference Proceedings (OSTI)

... “We wanted a standard that was ... as envisioned, then within our lifetimes there will no longer be a need for voltage transfer standards that have to be ...

2013-04-08T23:59:59.000Z

423

Evaluation of Pipe-Type Cable Joint Restraint Systems  

Science Conference Proceedings (OSTI)

Joints in underground transmission pipe-type cables must be designed to accommodate the thermomechanical forces created as a cable heats and cools in operation. This report details an investigation of several joint restraining designs and recommends one design.

1990-04-06T23:59:59.000Z

424

Applications of Increased Power Flow Strategies for Underground Cables  

Science Conference Proceedings (OSTI)

In 2003, the Electric Power Research Institute (EPRI) recognized that there were no detailed resources on the topic of increased power flow (sometimes called uprating) for underground cable systems. Transmission cables were often the focus of evaluations where utilities were seeking to get the greatest improvement in load transfer for a given investment. The 2003 EPRI report, Increased Power Flow Guidebook: Underground Cables, describes basic cable rating principles and ...

2013-11-21T23:59:59.000Z

425

Apparatus producing constant cable tension for intermittent demand  

DOE Patents (OSTI)

This invention relates to apparatus for producing constant tension in cable or the like when it is unreeled and reeled from a drum or spool under conditions of intermittent demand. The invention is particularly applicable to the handling of superconductive cable, but the invention is also applicable to the unreeling and reeling of other strands, such as electrical cable, wire, cord, other cables, fish line, wrapping paper and numerous other materials.

Lauritzen, T.

1984-05-23T23:59:59.000Z

426

Underground Cable Fault Location Reference and Application Guide  

Science Conference Proceedings (OSTI)

This report summarizes underground cable fault location methods and details the application of the methods for transmission and distribution cable systems. It summarizes both terminal location and tracer location methods that can be applied to transmission and distribution cable systems. The report is an update to a summary of fault location methods. It provides practical technical material in the art and science of locating cable faults, including a description of common fault location instruments and p...

2011-12-23T23:59:59.000Z

427

Complete Fiber/Copper Cable Solution for Long-Term Temperature and Pressure  

Open Energy Info (EERE)

Complete Fiber/Copper Cable Solution for Long-Term Temperature and Pressure Complete Fiber/Copper Cable Solution for Long-Term Temperature and Pressure Measurement in Supercritical Reservoirs and EGS Wells Geothermal Project Jump to: navigation, search Last modified on July 22, 2011. Project Title Complete Fiber/Copper Cable Solution for Long-Term Temperature and Pressure Measurement in Supercritical Reservoirs and EGS Wells Project Type / Topic 1 Recovery Act: Enhanced Geothermal Systems Component Research and Development/Analysis Project Type / Topic 2 High-Temperature Downhole Tools Project Description Draka has engaged top academic, national laboratory and industry research scientists to develop the myriad of technical advances required - from glass chemistry to encapsulation metallurgy. Draka will develop the required advances in buffer tubing, cladding, wire insulation materials and cable packaging as well as coordinate activities of other participants. Draka Communications will develop the required advances in glass chemistry, fiber coatings and fiber drawing technologies. AltaRock Energy, Inc., a renewable energy company focused on research & development, will provide well field services and EGS wells for long-term testing and validation of the cable at Geysers, California. Tetramer has been engaged for the required advances in candidate materials for fiber coating and encapsulation technologies. Sandia will provide laboratory testing and validation of Draka's fiber solutions at elevated temperatures, pressures and hydrogen levels. Permatools (a Sandia EGS spin-off) will provide EGS tools to validate the finished cable design and will also coordinate in-well testing. Permatools (a Sandia EGS spin-off) will provide EGS tools to validate the finished cable design and will also coordinate in-well testing.

428

Elevation cable modeling for interactive simulation of cranes  

Science Conference Proceedings (OSTI)

In this paper, the way to simulate hoisting cables in real time is addressed. We overcome instability in such simulation by considering a two-layered model: a model for the dynamics of a cable passing through a set of pulleys and an oscillation model ... Keywords: flexible cables, interactive simulation, physically-based animation

Ignacio García-Fernández; Marta Pla-Castells; Rafael J. Martínez-Durá

2008-07-01T23:59:59.000Z

429

Research on Fault Location of Power Cable with Wavelet Analysis  

Science Conference Proceedings (OSTI)

This article researChes for 10kV transmission cable form the ground substation to the underground central substation in the coal mine. The transient traveLing wave signal of the cable fault is disposed by the wavelet transformation based on the cable ... Keywords: Wavelet analysis, Fault Location, TraveLing wave

Ji-meng Zhang; Shuo Liang

2011-08-01T23:59:59.000Z

430

A Review of Nondestructive Evaluation Technologies for Cable System Integrity  

Science Conference Proceedings (OSTI)

This report provides an overview of common electrical cable types and designs, damage mechanisms, and existing test methods. It describes a technology review focused on assessing feasibility, performance, and limitations of nondestructive evaluation (NDE) technologies for cable integrity tests and inspection and summarizes future proposed work.BackgroundKnowing a cable system’s condition is essential to ensure the reliability of the connected ...

2013-11-21T23:59:59.000Z

431

Reactive Power Management to Address Short-Term Voltage Stability Using Optimal Reactive Power Allocation Method  

Science Conference Proceedings (OSTI)

Voltage stability has attracted attention recently because power systems are increasingly operated under heavy loads and subjected to high levels of dynamic fast acting loads. Voltage instability under these conditions can be manifested as depressed voltage profiles, delayed voltage recovery at load buses following a major disturbance, and even fast voltage collapse. Single-phase, low-inertia induction motors can have adverse effect on voltage stability as they decelerate in the event of voltage ...

2012-11-28T23:59:59.000Z

432

Substation voltage upgrading  

SciTech Connect

Substation voltage uprating, i.e., conversion of a substation from a lower rated voltage to a higher rated voltage without a complete substation rebuild, can lead to excellent economic benefits. Utilization of the old substation layout and/or the existing equipment, to some extent, is the practical objective of such an uprating. The objective of this project was to assess the opportunities for substation uprating in the industry, to establish feasibility for such uprating and to study methods for accomplishing it. The final aim of the project was to provide guidance to utilities interested in uprating. 56 refs., 41 figs., 18 tabs.

Panek, J.; Elahi, H.; Sublich, M. (General Electric Co., Schenectady, NY (USA). Systems Development and Engineering Dept.)

1989-08-01T23:59:59.000Z

433

Voltage Quality Improvement Using DVR  

Science Conference Proceedings (OSTI)

The problem of voltage sags and Swells and its severe impact on sensitive loads is well known. To solve this problem, custom power devices are used. One of those devices is the Dynamic Voltage Restorer (DVR), which is one of the most efficient and effective ... Keywords: Dynamic Voltage Restorer (DVR), Voltage sags, Voltage swells, Custom power, Power Quality

M. Arun Bhaskar; S. S. Dash; C. Subramani; M. Jagadeesh Kumar; P. R. Giresh; M. Varun Kumar

2010-03-01T23:59:59.000Z

434

Plant Engineering: Cable Aging Management Training: Identification of Adverse Environment, and Introduction to Visual/ Tactile Asses sment of Cable  

Science Conference Proceedings (OSTI)

Two cable aging management training modules are included that introduce the viewer to adverse environments and their effects on cable polymers and to visual tactile assessment of cables to determine if they have degraded from the adverse environments. The types of environments that are adverse with respect to cable materials and the locations in a plant where they might exist are provided. The visual/tactile presentation shows how basic properties and visual attributes may be used to determine ifcables a...

2011-10-19T23:59:59.000Z

435

Testing of 3-meter Prototype Fault Current Limiting Cables  

Science Conference Proceedings (OSTI)

Two 3-m long, single-phase cables have been fabricated by Ultera from second generation (2G) superconductor supplied by American Superconductor. The first cable was made with two layers of 2G tape conductor and had a critical current of 5,750 A while the second cable had four layers and a critical current of 8,500 A. AC loss was measured for both cables at ac currents of up to 4 kArms. Ultera performed initial fault current studies of both cables in Denmark with limited currents in the range from 9.1 to 44 kA. Results from these tests will provide a basis for a 25-m long, three-phase, prototype cable to be tested at ORNL early next year and a 300-m long, fault current limiting, superconducting cable to be installed in a ConEd substation in New York City.

Gouge, Michael J [ORNL; Duckworth, Robert C [ORNL; Demko, Jonathan A [ORNL; Rey, Christopher M [ORNL; Thompson, James R [ORNL; Lindsay, David T [ORNL; Tolbert, Jerry Carlton [ORNL; Willen, Dag [Ultera; Lentge, Heidi [Ultera; Thidemann, Carsten [Ultera; Carter, Bill [AMSC

2009-01-01T23:59:59.000Z

436

Condition Assessment Techniques for Laminar Dielectric Transmission Cable Systems--2012 Update  

Science Conference Proceedings (OSTI)

As aging and higher circuit loadings lead to increased failures of pipe-type cable systems, utilities need effective techniques for assessing the key components of these systems. Many off-line and on-line diagnostic and assessment techniques are in use to inspect the condition of laminar dielectric cable systems. Because of the high labor costs and required circuit outage of off-line testing, current research and development also focuses on methods of on-line monitoring.A number of ...

2012-11-06T23:59:59.000Z

437

Distributed Generation Source Stiffness and Its Impact on Voltage Distortion  

Science Conference Proceedings (OSTI)

Distributed generators with loads that create high harmonics can cause excessive voltage distortion. This report's objective was to evaluate under controlled laboratory conditions voltage distortion resulting from application of nonlinear load for three different types of rotary generators and one inverter-based generator. Test results also were used to verify the analytical model for predicting voltage distortion from nonlinear load application.

2001-11-27T23:59:59.000Z

438

Intrinsic Surface Stability in LiMn2-xNixO4-d (x=0.45, 0.5) High Volt-age Spinel Materials for Lithium Ion Batteries  

SciTech Connect

This work reports the surface stability of the high voltage Li ion cathode LiMn2-xNixO4- (x= 0.5, 0.45) by comparing thin film and powder composite electrodes after cycling using X-ray photoelectron spectroscopy. The thin film electrodes offer the ability to probe the surface of the material without the need of a conductive agent and polymer binder typically used in composite electrodes. The results suggest that neither oxidation of PF6 to POF5 nor the decomposition of ethylene carbonate or dimethylene carbonate occurs on the surface of the spinel material. These results confirm the enhanced cycling stability and rate capability associated with the high voltage spinel material and suggests that the SEI layer forms due to the reaction of electrochemically inactive components in composite electrodes with the electrolyte.

Carroll, Kyler J [University of California, San Diego; Yang, Ming-Che [University of Florida, Gainesville; Veith, Gabriel M [ORNL; Dudney, Nancy J [ORNL; Meng, Ying Shirley [University of California, San Diego

2012-01-01T23:59:59.000Z

439

Device for monitoring cell voltage  

SciTech Connect

A device for monitoring a rechargeable battery having a number of electrically connected cells includes at least one current interruption switch for interrupting current flowing through at least one associated cell and a plurality of monitoring units for detecting cell voltage. Each monitoring unit is associated with a single cell and includes a reference voltage unit for producing a defined reference threshold voltage and a voltage comparison unit for comparing the reference threshold voltage with a partial cell voltage of the associated cell. The reference voltage unit is electrically supplied from the cell voltage of the associated cell. The voltage comparison unit is coupled to the at least one current interruption switch for interrupting the current of at least the current flowing through the associated cell, with a defined minimum difference between the reference threshold voltage and the partial cell voltage.

Doepke, Matthias (Garbsen, DE); Eisermann, Henning (Edermissen, DE)

2012-08-21T23:59:59.000Z

440

Electron launching voltage monitor  

DOE Patents (OSTI)

An electron launching voltage monitor measures MITL voltage using a relationship between anode electric field and electron current launched from a cathode-mounted perturbation. An electron launching probe extends through and is spaced from the edge of an opening in a first MITL conductor, one end of the launching probe being in the gap between the MITL conductor, the other end being adjacent a first side of the first conductor away from the second conductor. A housing surrounds the launching probe and electrically connects the first side of the first conductor to the other end of the launching probe. A detector detects the current passing through the housing to the launching probe, the detected current being representative of the voltage between the conductors.

Mendel, Clifford W. (Albuquerque, NM); Savage, Mark E. (Albuquerque, NM)

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Economics of heat loss for power cables  

SciTech Connect

Energy losses occur in power cables which cause a rise in the conductor temperature. A trend toward higher allowable conductor temperatures has increased the energy losses during operation. At the same time, the costs of the energy has increased dramatically. With a given installation and load, energy costs vary inversely with the conductor size. However, initial costs vary directly with the conductor size. This relationship can be utilized to select a conductor size which minimizes the sum of the initial costs an the energy costs. This paper reviews present value techniques and identifies the level of energy costs in some particular installation configurations. An analysis is made of the marginal costs and savings available by changing the size of the conductor in a cable circuit.

Cornelison, K.E.

1982-07-01T23:59:59.000Z

442

Coaxial 30 kV Connectors for the RG220/U Cable 20 Years of Operational Experience  

E-Print Network (OSTI)

For the fast pulsed magnet system of CERN's SPS and LEP particle accelerators, a special type of moulded coaxial high voltage cable connector is used in large quantities. These connectors are mounted on coaxial transmission lines, which connect pulse generators in buildings at ground level to the fast pulsed magnets situated in an underground tunnel. Well over 1500 such connectors have already been installed and many more will be needed for the construction of the LHC. This 14 TeV Large Hadron Collider, which has a circumference of 27 km, is now under construction at CERN. The paper summarizes the operational experience over the last 20 years and the design principles of the connector. It explains how the excellent reliability and the extremely low failure rate were achieved and outlines the causes of the rare replacements. The paper also discusses the ageing effects caused by radiation, as well as wear and tear during installation and manipulation. Finally it gives a report on our experience with coaxial con...

Mayer, M

2000-01-01T23:59:59.000Z

443

Nuclear power plant cable materials : review of qualification and currently available aging data for margin assessments in cable performance.  

SciTech Connect

A selective literature review was conducted to assess whether currently available accelerated aging and original qualification data could be used to establish operational margins for the continued use of cable insulation and jacketing materials in nuclear power plant environments. The materials are subject to chemical and physical degradation under extended radiationthermal- oxidative conditions. Of particular interest were the circumstances under which existing aging data could be used to predict whether aged materials should pass loss of coolant accident (LOCA) performance requirements. Original LOCA qualification testing usually involved accelerated aging simulations of the 40-year expected ambient aging conditions followed by a LOCA simulation. The accelerated aging simulations were conducted under rapid accelerated aging conditions that did not account for many of the known limitations in accelerated polymer aging and therefore did not correctly simulate actual aging conditions. These highly accelerated aging conditions resulted in insulation materials with mostlyinert' aging processes as well as jacket materials where oxidative damage dropped quickly away from the air-exposed outside jacket surface. Therefore, for most LOCA performance predictions, testing appears to have relied upon heterogeneous aging behavior with oxidation often limited to the exterior of the cable cross-section - a situation which is not comparable with the nearly homogenous oxidative aging that will occur over decades under low dose rate and low temperature plant conditions. The historical aging conditions are therefore insufficient to determine with reasonable confidence the remaining operational margins for these materials. This does not necessarily imply that the existing 40-year-old materials would fail if LOCA conditions occurred, but rather that unambiguous statements about the current aging state and anticipated LOCA performance cannot be provided based on original qualification testing data alone. The non-availability of conclusive predictions for the aging conditions of 40-year-old cables implies that the same levels of uncertainty will remain for any re-qualification or extended operation of these cables. The highly variable aging behavior of the range of materials employed also implies that simple, standardized aging tests are not sufficient to provide the required aging data and performance predictions for all materials. It is recommended that focused studies be conducted that would yield the material aging parameters needed to predict aging behaviors under low dose, low temperature plant equivalent conditions and that appropriately aged specimens be prepared that would mimic oxidatively-aged 40- to 60- year-old materials for confirmatory LOCA performance testing. This study concludes that it is not sufficient to expose materials to rapid, high radiation and high temperature levels with subsequent LOCA qualification testing in order to predictively quantify safety margins of existing infrastructure with regard to LOCA performance. We need to better understand how cable jacketing and insulation materials have degraded over decades of power plant operation and how this aging history relates to service life prediction and the performance of existing equipment to withstand a LOCA situation.

Celina, Mathias Christopher; Gillen, Kenneth Todd; Lindgren, Eric Richard

2013-05-01T23:59:59.000Z

444

Nuclear power plant cable materials : review of qualification and currently available aging data for margin assessments in cable performance.  

Science Conference Proceedings (OSTI)

A selective literature review was conducted to assess whether currently available accelerated aging and original qualification data could be used to establish operational margins for the continued use of cable insulation and jacketing materials in nuclear power plant environments. The materials are subject to chemical and physical degradation under extended radiationthermal- oxidative conditions. Of particular interest were the circumstances under which existing aging data could be used to predict whether aged materials should pass loss of coolant accident (LOCA) performance requirements. Original LOCA qualification testing usually involved accelerated aging simulations of the 40-year expected ambient aging conditions followed by a LOCA simulation. The accelerated aging simulations were conducted under rapid accelerated aging conditions that did not account for many of the known limitations in accelerated polymer aging and therefore did not correctly simulate actual aging conditions. These highly accelerated aging conditions resulted in insulation materials with mostlyinert' aging processes as well as jacket materials where oxidative damage dropped quickly away from the air-exposed outside jacket surface. Therefore, for most LOCA performance predictions, testing appears to have relied upon heterogeneous aging behavior with oxidation often limited to the exterior of the cable cross-section - a situation which is not comparable with the nearly homogenous oxidative aging that will occur over decades under low dose rate and low temperature plant conditions. The historical aging conditions are therefore insufficient to determine with reasonable confidence the remaining operational margins for these materials. This does not necessarily imply that the existing 40-year-old materials would fail if LOCA conditions occurred, but rather that unambiguous statements about the current aging state and anticipated LOCA performance cannot be provided based on original qualification testing data alone. The non-availability of conclusive predictions for the aging conditions of 40-year-old cables implies that the same levels of uncertainty will remain for any re-qualification or extended operation of these cables. The highly variable aging behavior of the range of materials employed also implies that simple, standardized aging tests are not sufficient to provide the required aging data and performance predictions for all materials. It is recommended that focused studies be conducted that would yield the material aging parameters needed to predict aging behaviors under low dose, low temperature plant equivalent conditions and that appropriately aged specimens be prepared that would mimic oxidatively-aged 40- to 60- year-old materials for confirmatory LOCA performance testing. This study concludes that it is not sufficient to expose materials to rapid, high radiation and high temperature levels with subsequent LOCA qualification testing in order to predictively quantify safety margins of existing infrastructure with regard to LOCA performance. We need to better understand how cable jacketing and insulation materials have degraded over decades of power plant operation and how this aging history relates to service life prediction and the performance of existing equipment to withstand a LOCA situation.

Celina, Mathias Christopher; Gillen, Kenneth Todd; Lindgren, Eric Richard

2013-05-01T23:59:59.000Z

445

Field Demonstration of a 24-kV Warm Dielectric Cable at Detroit Edison: FY2002 Annual Progress Report for the Detroit Edison HTS Cab le Field Demonstration Project  

Science Conference Proceedings (OSTI)

A project sponsored by EPRI, Pirelli Power Cables and Systems, the Department of Energy, Detroit Edison, and American Superconductor Corporation was initiated in 1998 to install and operate a 24 kV high temperature superconductor (HTS) power cable in a Detroit Edison substation to serve customer load. The previous years of activity have focused on design, testing, manufacturing, and installation of the cable system as described in the FY2000 and FY2001 status reports. The successful implementation of thi...

2003-02-26T23:59:59.000Z

446

Armored spring-core superconducting cable and method of construction  

DOE Patents (OSTI)

An armored spring-core superconducting cable (12) is provided. The armored spring-core superconducting cable (12) may include a spring-core (20), at least one superconducting strand (24) wound onto the spring-core (20), and an armored shell (22) that encases the superconducting strands (24). The spring-core (20) is generally a perforated tube that allows purge gases and cryogenic liquids to be circulated through the armored superconducting cable (12), as well as managing the internal stresses within the armored spring-core superconducting cable (12). The armored shell (22) manages the external stresses of the armored spring-core superconducting cable (12) to protect the fragile superconducting strands (24). The armored spring-core superconducting cable (12) may also include a conductive jacket (34) formed outwardly of the armored shell (22).

McIntyre, Peter M. (611 Montclair, College Station, TX 77840); Soika, Rainer H. (1 Hensel, #X4C, College Station, TX 77840)

2002-01-01T23:59:59.000Z

447

Tidal Transport in the Florida Current and Its Relationship to Tidal Heights and Cable Voltages  

Science Conference Proceedings (OSTI)

A linear relationship between tidal height (sea level of tidal frequencies) and tidal transport near 27°N in the Straits of Florida is confirmed. Transport estimates from this relationship for the O1 and M2 constituents are compared with those ...

Dennis A. Mayer; Jimmy C. Larsen

1986-12-01T23:59:59.000Z

448

Underground Transmission Cable System Installation and Construction Practices Manual  

Science Conference Proceedings (OSTI)

Installation and construction remain the most expensive implementation components of underground transmission cable systems. Recent advancements in underground transmission have led to more demand for best practices and innovative ways to reduce installation and construction costs in a cable project. EPRI has funded many projects over the years to improve the efficiency and reduce the cost of underground transmission cable installation. Other organizations such as Association of Edison Illuminating Compa...

2009-12-22T23:59:59.000Z

449

Underwater-cable power-transmission system: bottom segment design  

DOE Green Energy (OSTI)

After a survey of the state of the art for bottom cables, some possible configurations are considered for candidate OTEC sites. General considerations on laying and embedding are discussed, and solutions are considered. Optimization of cable dimensions and the problem of flexible joints are covered. The state of the art of cable installation and repair is reviewed and discussed with reference to the representative OTEC sites. Costs for shore terminal stations are evaluated. (LEW)

Not Available

1978-11-01T23:59:59.000Z

450

Low voltage arc formation in railguns  

DOE Patents (OSTI)

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, R.S.

1985-08-05T23:59:59.000Z

451

Low voltage arc formation in railguns  

DOE Patents (OSTI)

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, Ronald S. (Livermore, CA)

1987-01-01T23:59:59.000Z

452

Low voltage arc formation in railguns  

DOE Patents (OSTI)

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile. 2 figs.

Hawke, R.S.

1987-11-17T23:59:59.000Z

453

The Current-voltage Characteristics of Grain Boundaries in Ionic ...  

Science Conference Proceedings (OSTI)

Presentation Title, The Current-voltage Characteristics of Grain Boundaries in Ionic ... A High-temperature Mössbauer Study of Iron-doped Ruddlesden-popper  ...

454

Voltage Controlled Creep of a Nanoporous Gold/Electrolyte Hybrid ...  

Science Conference Proceedings (OSTI)

And the creep rate can also be controlled by the voltage (electrochemical ... CNT Reinforced Copper Composite for High Contact Pressure Electrodes by ...

455

Patents and Perspective on Surge Protection for Low-Voltage ...  

Science Conference Proceedings (OSTI)

... In a high-voitage inverter the impedance is a resistor functioning to dampen voltage o\\ershoots and to im- plement a relay or solid state second ...

2013-05-17T23:59:59.000Z

456

PROPOSAL Characterization of Field and Lab Aged Cables  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DoE Peer Review Nov 2010 2 * Underground cable system infrastructure is complex and aging. * Failures are increasing * If not addressed then old infrastructure will not support...

457

Electrical Cable Testing by Pulse-Arrested Spark Discharge ...  

... useful to determine the location of defect sites in critical but inaccessible electrical cabling systems in aging aircraft, ships, nuclear power ...

458

Recycling of Cross-linked Polyethylene Cable Waste via Mechanical ...  

Science Conference Proceedings (OSTI)

Cable industry in UAE contributes in large amount of plastic waste, where the .... Production of Heavy Pipeline Plate for Submarine Gas Transmission Lines at ...

459

Program on Technology Innovation: A Superconducting DC Cable  

Science Conference Proceedings (OSTI)

Shortly after the beginning of the twentieth century, dc power transmission was replaced by ac in order to achieve efficient transmission of electric power over long distances with available conductors and at safe distribution voltages. However, dc power was not completely abandoned, and the advent of solid-state power electronic ac-to-dc conversion equipment has reinvigorated its application. High-voltage dc power is more desirable for long-range transmission than ac in many ways: dc uses two wires rath...

2009-12-15T23:59:59.000Z

460

High Voltage Test Apparatus for a Neutron EDM Experiment and Lower Limit on the Dielectric Strength of Liquid Helium at Large Volumes  

E-Print Network (OSTI)

A new search for a permanent electric dipole moment (EDM) of the neutron is underway using ultracold neutrons produced and held in a bath of superfluid helium. Attaining the target sensitivity requires maintaining an electric field of several tens of kilovolts per centimeter across the experimental cell, which is nominally 7.5 cm wide and will contain about 4 liters of superfluid. The electrical properties of liquid helium are expected to be sufficient to meet the design goals, but little is known about these properties for volumes and electrode spacings appropriate to the EDM experiment. Furthermore, direct application of the necessary voltages from an external source to the experimental test cell is impractical. An apparatus to amplify voltages in the liquid helium environment and to test the electrical properties of the liquid for large volumes and electrode spacings has been constructed. The device consists of a large-area parallel plate capacitor immersed in a 200 liter liquid helium dewar. Preliminary results show the breakdown strength of normal state liquid helium is at least 90 kV/cm at these volumes, at the helium vapor pressure corresponding to 4.38 K. These fields hold for more than 11 hours with leakage currents less than 170 pA (about 20% of the maximum tolerable in the EDM experiment). The system is also found to be robust against anticipated radiation backgrounds. Preliminary results for superfluid show that fields of at least 30 kV/cm can be sustained at the volumes required for the EDM experiment, about 60% of the design goal. These results are likely limited by the low pressure that must be maintained above the superfluid bath.

J. C. Long; P. D. Barnes; J. G. Boissevain; D. J. Clark; M. D. Cooper; J. J. Gomez; S. K. Lamoreaux; R. E. Mischke; S. I. Penttila

2006-03-27T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Automatic voltage-imbalance detector  

DOE Patents (OSTI)

A device is described for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

Bobbett, R.E.; McCormick, J.B.; Kerwin, W.J.

1981-05-20T23:59:59.000Z

462

OTEC riser cable system, Phase II: conceptual design  

SciTech Connect

Studies are summarized of conceptual designs of riser cable systems for OTEC pilot plants of both the spar and plantship configurations located at sites off the southeast coast of Puerto Rico. The studies utilize a baseline pilot plant riser cable, the design of which has been developed and reported on in other reports. Baseline riser cable systems for OTEC pilot plants are identified, system hardware consistent with these designs are conceptualized, and comparisons of the various system concepts are provided. It is concluded that there are three riser cable systems feasible for a spar pilot plant platform at the Punta Yeguas site, and two riser cable systems feasible at the plantship pilot plant at the Punta Tuna site. Recommendations for further investigations in the areas of materials, hardware design and pre-installation site surveys are also addressed.

Not Available

1980-10-01T23:59:59.000Z

463

Original article: Selective compensation of voltage harmonics in grid-connected microgrids  

Science Conference Proceedings (OSTI)

In this paper, a novel approach is proposed for selective compensation of main voltage harmonics in a grid-connected microgrid. The aim of compensation is to provide a high voltage quality at the point of common coupling (PCC). PCC voltage quality is ... Keywords: Distributed generator (DG), Grid-connected, Microgrid, Voltage harmonics compensation

Mehdi Savaghebi, Juan C. Vasquez, Alireza Jalilian, Josep M. Guerrero, Tzung-Lin Lee

2013-05-01T23:59:59.000Z

464

Sequential circuit design for radiation hardened multiple voltage integrated circuits  

DOE Patents (OSTI)

The present invention includes a radiation hardened sequential circuit, such as a bistable circuit, flip-flop or other suitable design that presents substantial immunity to ionizing radiation while simultaneously maintaining a low operating voltage. In one embodiment, the circuit includes a plurality of logic elements that operate on relatively low voltage, and a master and slave latches each having storage elements that operate on a relatively high voltage.

Clark, Lawrence T. (Phoenix, AZ); McIver, III, John K. (Albuquerque, NM)

2009-11-24T23:59:59.000Z

465

Planning of distribution networks for medium voltage and low voltage.  

E-Print Network (OSTI)

??Determination of the placement and rating of transformers and feeders are the main objective of the basic distribution network planning. The bus voltage and the… (more)

Ziari, Iman

2011-01-01T23:59:59.000Z

466

Electrochemical and rate performance study of high-voltage lithium-richcomposition: Li1.2Mn0.525Ni0.175Co0.1O2  

Science Conference Proceedings (OSTI)

We report electrochemical studies of high voltage cathodes composed of lithium rich layeredlayered material having the nominal composition Li1.2Mn0.525Ni0.175Co0.1O2, or equivalently 0.6Li[Li1/3Mn2/3]O2 0.4Li[Mn0.3Ni0.45Co0.25]O2. These aspects were investigated by cyclic voltammetry studies in conjunction with electrochemical impedance spectroscopy measurements to understand the redox reactions involving multiple transition metals and their capacity contribution at higher voltages, up to 4.9 V. Further, cathodes with 1.5 wt.% carbon nanofibers added to the Li1.2Mn0.525Ni0.175Co0.1O2 composite electrode showed stable reversible capacities of about 280 mAh g 1 when cycled to 4.9 V for more than 100 cycles, and almost a factor of two improvements in the rate performance compared to the electrode composition prepared using conventional composition (7.5% carbon black and 7.5% binder).

Martha, Surendra K [ORNL; Nanda, Jagjit [ORNL; Veith, Gabriel M [ORNL; Dudney, Nancy J [ORNL

2012-01-01T23:59:59.000Z

467

Method for fabricating multi-strand superconducting cable  

DOE Patents (OSTI)

Multi-strand superconducting cables adapted to be used, for example, to wind a magnet are fabricated by directing wire strands inwardly from spools disposed on the perimeter of a rotating disk and wrapping them diagonally around a tapered mandrel with a flattened cross-sectional shape with a core having a wedge-shaped channel. As the cable is pulled axially, flexibly coupled wedge-shaped pieces are continuously passed through the channel in the mandrel and inserted into the cable as an internal support therefor.

Borden, A.R.

1985-04-01T23:59:59.000Z

468

Apparatus and method for fabricating multi-strand superconducting cable  

DOE Patents (OSTI)

Multi-strand superconducting cables adapted to be used, for example, to wind a magnet is fabricated by directing wire strands inwardly from spools disposed on the perimeter of a rotating disk and wrapping them diagonally around a tapered mandrel with a flattened cross-sectional shape with a core having a wedge-shaped channel. As the cable is pulled axially, flexibly coupled wedge-shaped pieces are continuously passed through the channel in the mandrel and inserted into the cable as an internal support therefor.

Borden, Albert R. (El Cerrito, CA)

1986-01-01T23:59:59.000Z

469

Method and apparatus for making multistrand superconducting cable  

DOE Patents (OSTI)

Improved multistrand Rutherford-type superconducting cable is produced in a flattened form with two layers of helically wound strands and in which the strands are alternately twisted about their lengths equally and in opposite directions to provide a flat cable with improved stability. In particular, the cable is made by guiding multifilament wire strands from spools on a rotating turret to a fixed tapered forming mandrel where they are wound diagonally around the mandrel and then rolled into a flattened shape. The spools are located around the periphery of turret and are rotatable about axes in a plane parallel to the turret to unroll the wire.

Royet, J.M.; Armer, R.A.

1989-03-14T23:59:59.000Z

470

Humidity, Temperature, and Voltage (Presentation)  

SciTech Connect

An update is given on the work of the PV Quality Assurance Task Force; Group 3: studying the effects of humidity, temperature, and voltage bias.

Wohlgemuth, J.