Powered by Deep Web Technologies
Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Partial discharge measurements on a high voltage direct current mass impregnated paper cable  

SciTech Connect (OSTI)

Partial discharge measurement has been a good tool for the quality assurance of cables under alternating voltage. With the growing interest in High Voltage Direct Current cables it seems therefore logical to extend this technique for use at direct voltage. The paper describes this technique as used on a HVDC cable with mass impregnated paper. The different phases of operation (no load, full load, cooling phase, etc.) are characterized by a different discharge behavior. Special attention is given to the dangerous cooling phase. Models have been developed which can explain the discharge patterns that were measured. This paper gives an insight in the electrical behavior of a HVDC cable with mass impregnated paper insulation.

Jeroense, M.J.P. [NKF KABEL B.V., Delft (Netherlands); Kreuger, F.H. [Delft Univ. of Technology (Netherlands)

1996-12-31T23:59:59.000Z

2

Measurement of low radioactivity background in a high voltage cable by high resolution inductively coupled plasma mass spectrometry  

SciTech Connect (OSTI)

The measurement of naturally occurring low level radioactivity background in a high voltage (HV) cable by high resolution inductively coupled plasma mass spectrometry (HR ICP MS) is presented in this work. The measurements were performed at the Chemistry Service of the Gran Sasso National Laboratory. The contributions to the radioactive background coming from the different components of the heterogeneous material were separated. Based on the mass fraction of the cable, the whole contamination was calculated. The HR ICP MS results were cross-checked by gamma ray spectroscopy analysis that was performed at the low background facility STELLA (Sub Terranean Low Level Assay) of the LNGS underground lab using HPGe detectors.

Vacri, M. L. di; Nisi, S.; Balata, M. [Gran Sasso National Laboratory, Chemistry Service, SS 17bis km 18.910, 67100 Assergi (Aq) (Italy)] [Gran Sasso National Laboratory, Chemistry Service, SS 17bis km 18.910, 67100 Assergi (Aq) (Italy)

2013-08-08T23:59:59.000Z

3

Commercialization of Medium Voltage HTS Triax TM Cable Systems  

SciTech Connect (OSTI)

The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax{TM} cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed the market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax{TM} cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS TriaxTM design, so it provided an economical tool for these of the project tasks.

Knoll, David

2012-12-31T23:59:59.000Z

4

High conductance surge cable  

DOE Patents [OSTI]

An electrical cable for connecting transient voltage surge suppressors to electrical power panels. A strip of electrically conductive foil defines a longitudinal axis, with a length of an electrical conductor electrically attached to the metallic foil along the longitudinal axis. The strip of electrically conductive foil and the length of an electrical conductor are covered by an insulating material. For impedance matching purposes, triangular sections can be removed from the ends of the electrically conductive foil at the time of installation. 6 figs.

Murray, M.M.; Wilfong, D.H.; Lomax, R.E.

1998-12-08T23:59:59.000Z

5

High conductance surge cable  

DOE Patents [OSTI]

An electrical cable for connecting transient voltage surge suppressers to ectrical power panels. A strip of electrically conductive foil defines a longitudinal axis, with a length of an electrical conductor electrically attached to the metallic foil along the longitudinal axis. The strip of electrically conductive foil and the length of an electrical conductor are covered by an insulating material. For impedance matching purposes, triangular sections can be removed from the ends of the electrically conductive foil at the time of installation.

Murray, Matthew M. (Espanola, NM); Wilfong, Dennis H. (Brooksville, FL); Lomax, Ralph E. (Santa Fe, NM)

1998-01-01T23:59:59.000Z

6

High Temperature Superconducting Underground Cable  

SciTech Connect (OSTI)

The purpose of this Project was to design, build, install and demonstrate the technical feasibility of an underground high temperature superconducting (HTS) power cable installed between two utility substations. In the first phase two HTS cables, 320 m and 30 m in length, were constructed using 1st generation BSCCO wire. The two 34.5 kV, 800 Arms, 48 MVA sections were connected together using a superconducting joint in an underground vault. In the second phase the 30 m BSCCO cable was replaced by one constructed with 2nd generation YBCO wire. 2nd generation wire is needed for commercialization because of inherent cost and performance benefits. Primary objectives of the Project were to build and operate an HTS cable system which demonstrates significant progress towards commercial progress and addresses real world utility concerns such as installation, maintenance, reliability and compatibility with the existing grid. Four key technical areas addressed were the HTS cable and terminations (where the cable connects to the grid), cryogenic refrigeration system, underground cable-to-cable joint (needed for replacement of cable sections) and cost-effective 2nd generation HTS wire. This was the world’s first installation and operation of an HTS cable underground, between two utility substations as well as the first to demonstrate a cable-to-cable joint, remote monitoring system and 2nd generation HTS.

Farrell, Roger, A.

2010-02-28T23:59:59.000Z

7

High Voltage Safety Act  

Broader source: Energy.gov [DOE]

The purpose of the High Voltage Safety Act is to prevent injury to persons and property and interruptions of utility service resulting from accidental or inadvertent contact with high-voltage...

8

ABBGroup-1-High voltage lab  

E-Print Network [OSTI]

oscillations are due to travelling waves in the heating volume. #12;©ABBGroup-9- 3-Sep-07 2. High voltage phase interrupts the injected current, it is stressed by the transient recovery voltage (TRV) oscillating©ABBGroup-1- 3-Sep-07 High voltage lab Research on high voltage gas circuit breakers Nils P. Basse

Basse, Nils Plesner

9

High voltage DC power supply  

DOE Patents [OSTI]

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively. 7 figs.

Droege, T.F.

1989-12-19T23:59:59.000Z

10

High voltage DC power supply  

DOE Patents [OSTI]

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively.

Droege, Thomas F. (Batavia, IL)

1989-01-01T23:59:59.000Z

11

High voltage pulse conditioning  

DOE Patents [OSTI]

Apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close.

Springfield, Ray M. (Sante Fe, NM); Wheat, Jr., Robert M. (Los Alamos, NM)

1990-01-01T23:59:59.000Z

12

An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.  

SciTech Connect (OSTI)

References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

Litzenberger, Wayne; Lava, Val

1994-08-01T23:59:59.000Z

13

A Superconducting transformer system for high current cable testing  

E-Print Network [OSTI]

A Superconducting Transformer System for High Current Cablea Direct-Current (DC) superconducting transformer system forhigh current test of superconducting cables. The transformer

Godeke, A.

2010-01-01T23:59:59.000Z

14

Process of modifying a cable end  

DOE Patents [OSTI]

End moldings for high-voltage cables are described wherein the dielectric insulator of the cable is heated and molded to conform to a desired shape. As a consequence, high quality substantially bubble-free cable connectors suitable for mating to premanufactured fittings are made. Disclosed are a method for making the cable connectors either in the field or in a factory, molds suitable for use with the method, and the molded cable connectors, themselves. 5 figs.

Roose, L.D.

1995-08-01T23:59:59.000Z

15

CABLE TECHNOLOGY LABORATORIES, INC. DETERMINATION OF THRESHOLD...  

Office of Scientific and Technical Information (OSTI)

CABLE TECHNOLOGY LABORATORIES, INC. DETERMINATION OF THRESHOLD AND MAXIMUM OPERATING ELECTRIC STRESSES FOR SELECTED HIGH VOLTAGE INSULATIONS Investigation of Aged Polymeric...

16

Assessing Deterioration of ADSS Fiber Optic Cables  

E-Print Network [OSTI]

Assessing Deterioration of ADSS Fiber Optic Cables Due to Corona Discharge Final Project Report of ADSS Fiber Optic Cables Due to Corona Discharge Final Project Report George G. Karady, Project Leader-Supporting) fiber optic cables installed on high voltage lines. The high electric field on those lines generates

17

Results of a literature review on the environmental qualification of low-voltage electric cables  

SciTech Connect (OSTI)

In the design of nuclear power plants in the US, safety-related electric equipment must be qualified to provide reasonable assurance it can withstand the effects of a design basis event (DBE) and still be able to perform its prescribed safety function, even if the accident were to occur at the end of its service life. The requirement for environmental qualification (EQ) originates from the General Design Criteria in the Code of Federal Regulations, Title 10, Part 50 (10 CFR 50). The acceptable method of performing the qualification of this equipment has evolved over the years, starting with the NRC Division of Operating Reactors (DOR) Guidelines, which were issued in Bulletin 79--01B, and NUREG-0588 requirements and ending with the current EQ Rule, 10 CFR 50.49. While the EQ methods described in these documents have the same overall objective, there are some notable differences for which a clear technical basis has not been established. One difference is the preaging requirement for equipment prior to LOCA testing. In addition, specific issues related to current EQ practices have been raised by the US NRC which need to be addressed. These issues, which are discussed in detail later in this paper, are related to the sources of conservatism and uncertainty in IEEE Standard 323--1974, which is the qualification standard currently endorsed by the NRC. To address these issues, the NRC Office of Nuclear Reactor Regulation (NRR) implemented a Task Action Plan (TAP), and the Office of Nuclear Reactor Research (RES) initiated a complementary research program. The current focus of this program is on the qualification of low-voltage instrumentation and control cables. These cables were selected since they are not typically replaced on a routine basis, and their degradation could impact plant safety.

Lofaro, R.; Lee, B.; Villaran, M. [Brookhaven National Lab., Upton, NY (United States); Gleason, J. [GLS Enterprises, Inc. (United States); Aggarwal, S. [Nuclear Regulatory Commission, Washington, DC (United States)

1995-12-31T23:59:59.000Z

18

High voltage photovoltaic power converter  

DOE Patents [OSTI]

An array of independently connected photovoltaic cells on a semi-insulating substrate contains reflective coatings between the cells to enhance efficiency. A uniform, flat top laser beam profile is illuminated upon the array to produce electrical current having high voltage. An essentially wireless system includes a laser energy source being fed through optic fiber and cast upon the photovoltaic cell array to prevent stray electrical signals prior to use of the current from the array. Direct bandgap, single crystal semiconductor materials, such as GaAs, are commonly used in the array. Useful applications of the system include locations where high voltages are provided to confined spaces such as in explosive detonation, accelerators, photo cathodes and medical appliances.

Haigh, Ronald E. (Arvada, CO); Wojtczuk, Steve (Cambridge, MA); Jacobson, Gerard F. (Livermore, CA); Hagans, Karla G. (Livermore, CA)

2001-01-01T23:59:59.000Z

19

Performance of reduced wall EPR insulated medium voltage power cables. Pat 1: Electrical characteristics  

SciTech Connect (OSTI)

Paper insulated lead covered cables (PILC) have had a long and successful heritage. After almost 100 years, this design of cable is still in operation and continues to be manufactured. However, utilities are now looking for a reliable replacement for PILC cables. This is due to two primary reasons: (1) difficulty in installing and maintaining this type of cable and (2) increasing pressure to replace these cables due to environmental concerns. To date diameter limitations of conventional extruded dielectric cables has impeded their replacement in existing PILC conduits. This paper describes a study for the evaluation for reliably reducing the insulation thickness to achieve a lower diameter cable to effectively replace PILC cable in existing conduits. Part 1 of the investigation reviews the theory of insulation wall determination and the test program carried out to evaluate electrical performance of reduced wall EPR cables. Additionally, cable design concepts and constructions are discussed. In Part 2 the mechanical performance on conventional and reduced wall EPR insulated cables are evaluated. This is reported in a separate paper.

Cinquemani, P.L.; Wen, Y.; Kuchta, F.L.; Doench, C. [Pirelli Cable Corp., Lexington, SC (United States)] [Pirelli Cable Corp., Lexington, SC (United States)

1997-04-01T23:59:59.000Z

20

Performance of reduced wall EPR insulated medium voltage power cables. Part 2: Mechanical characteristics  

SciTech Connect (OSTI)

For the replacement of paper insulated lead covered cables (PILC) reduced insulation wall designs have been developed. They provide a reliable lower diameter cable design for installation in existing PILC conduits. Representing Part 2 of the investigation, this paper presents the results of mechanical testing conducted on both reduced and full wall EPR insulated cables. Both jacketed and non-jacketed cable designs have been subjected to mechanical pulling forces which greatly exceed recommended industry limitations, followed by electrical testing to ascertain cable performance. The results of this study conclude that reduced wall EPR insulated cables can safely withstand the same pulling forces as recommended for conventional walls and can be designed for installation under the same pulling limitations.

Wen, Y.; Cinquemani, P.L. [Pirelli Cable Corp., Lexington, SC (United States)

1997-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

ELECTRICAL AGING OF 15 KV EPR CABLES ENERGIZED BY AC VOLTAGE WITH SWITCHING IMPULSES SUPERIMPOSED.  

E-Print Network [OSTI]

?? In this study, the electrical aging of 15 kV Ethylene Propylene Rubber (EPR) power cables, located in PVC pipes containing water, was conducted by… (more)

Zanwar, Anand Umeshlal

2011-01-01T23:59:59.000Z

22

Radiation Testing of a Low Voltage Silicone Nuclear Power Plant Cable.  

SciTech Connect (OSTI)

This report summarizes the results generated in FY13 for cable insulation in support of the Department of Energy's Light Water Reactor Sustainability (LWRS) Program, in collaboration with the US-Argentine Binational Energy Working Group (BEWG). A silicone (SiR) cable, which was stored in benign conditions for ~30 years, was obtained from Comision Nacional de Energia Atomica (CNEA) in Argentina with the approval of NA-SA (Nucleoelectrica Argentina Sociedad Anonima). Physical property testing was performed on the as-received cable. This cable was artificially aged to assess behavior with additional analysis. SNL observed appreciable tensile elongation values for all cable insulations received, indicative of good mechanical performance. Of particular note, the work presented here provides correlations between measured tensile elongation and other physical properties that may be potentially leveraged as a form of condition monitoring (CM) for actual service cables. It is recognized at this point that the polymer aging community is still lacking the number and types of field returned materials that are desired, but Sandia National Laboratories (SNL) -- along with the help of others -- is continuing to work towards that goal. This work is an initial study that should be complimented with location-mapping of environmental conditions of Argentinean plant conditions (dose and temperature) as well as retrieval, analysis, and comparison with in- service cables.

White II, Gregory Von; Schroeder, John Lee.; Sawyer, Patricia Sue.; Wichhart, Derek; Mata, Guillermo Adrian; Zorrilla, Jorge; Bernstein, Robert

2014-09-01T23:59:59.000Z

23

Radiation Testing of a Low Voltage Silicone Nuclear Power Plant Cable.  

SciTech Connect (OSTI)

This report summarizes the results generated in FY13 for cable insulation in support of DOE's Light Water Reactor Sustainability (LWRS) Program, in collaboration with the US- Argentine Binational Energy Working Group (BEWG). A silicone (SiR) cable, which was stored in benign conditions for ~30 years, was obtained from Comision Nacional de Energia Atomica (CNEA) in Argentina. Physical property testing was performed on the as-received cable. This cable was artificially aged to assess behavior with additional analysis. SNL observed appreciable tensile elongation values for all cable insulations received, indicative of good mechanical performance. Of particular note, the work presented here provides correlations between measured tensile elongation and other physical properties that may be potentially leveraged as a form of condition monitoring (CM) for actual service cables. It is recognized at this point that the polymer aging community is still lacking the number and types of field returned materials that are desired, but SNL -- along with the help of others -- is continuing to work towards that goal. This work is an initial study that should be complimented with location- mapping of environmental conditions of CNEA plant conditions (dose and temperature) as well as retrieval, analysis, and comparison with in-service cables.

Bernstein, Robert

2014-08-01T23:59:59.000Z

24

High Voltage Electrolyte for Lithium Batteries  

Broader source: Energy.gov (indexed) [DOE]

battery using high voltage high energy cathode materials to enable large-scale, cost competitive production of the next generation of electric-drive vehicles. To...

25

High voltage load resistor array  

DOE Patents [OSTI]

A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

Lehmann, Monty Ray (Smithfield, VA)

2005-01-18T23:59:59.000Z

26

Low power, scalable multichannel high voltage controller  

DOE Patents [OSTI]

A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

Stamps, James Frederick (Livermore, CA); Crocker, Robert Ward (Fremont, CA); Yee, Daniel Dadwa (Dublin, CA); Dils, David Wright (Fort Worth, TX)

2006-03-14T23:59:59.000Z

27

Low power, scalable multichannel high voltage controller  

DOE Patents [OSTI]

A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

Stamps, James Frederick (Livermore, CA); Crocker, Robert Ward (Fremont, CA); Yee, Daniel Dadwa (Dublin, CA); Dils, David Wright (Fort Worth, TX)

2008-03-25T23:59:59.000Z

28

Fully synthetic taped insulation cables  

DOE Patents [OSTI]

The present invention is a cable which, although constructed from inexpensive polyolefin tapes and using typical impregnating oils, furnishes high voltage capability up to 765 kV, and has such excellent dielectric characteristics and heat transfer properties that it is capable of operation at capacities equal to or higher than presently available cables at a given voltage. This is accomplished by using polyethylene, polybutene or polypropylene insulating tape which has been specially processed to attain properties which are not generally found in these materials, but are required for their use in impregnated electrical cables. Chief among these properties is compatibility with impregnating oil.

Forsyth, E.B.; Muller, A.C.

1983-07-15T23:59:59.000Z

29

Measurements for validation of high voltage underground cable modelling  

E-Print Network [OSTI]

in part by the Danish TSO, Energinet.dk. U.S.G. is a PhD student at the Institute of Energy Technology.L.B. is with the Institute of Energy Technology, Aalborg University, 9220 Aalborg, Denmark (clb@iet.aau.dk). W

Bak, Claus Leth

30

E-Print Network 3.0 - aged xlpe cables Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3 (1993) 1083-1091 JUNE 1993, PAGE 1083 Classification Summary: ) and Cross-linked Polyethylene (XLPE) directly cut into high voltage cables. The pressure is obtained... .72...

31

Fully synthetic taped insulation cables  

DOE Patents [OSTI]

A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

Forsyth, Eric B. (Brookhaven, NY); Muller, Albert C. (Center Moriches, NY)

1984-01-01T23:59:59.000Z

32

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2012 DOE Hydrogen and Fuel Cells Program and...

33

Vehicle Technologies Office Merit Review 2014: High-Voltage Solid...  

Broader source: Energy.gov (indexed) [DOE]

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles Vehicle Technologies Office Merit Review 2014: High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...

34

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...  

Broader source: Energy.gov (indexed) [DOE]

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2013 DOE Hydrogen and Fuel Cells Program and...

35

Electro-optic high voltage sensor  

DOE Patents [OSTI]

A small sized electro-optic voltage sensor capable of accurate measurement of high voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation. A polarization beam displacer separates the input beam into two beams with orthogonal linear polarizations and causes one linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels effect elliptically polarizes the beam as it travels through the crystal. A reflector redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization. The system may include a detector for converting the output beams into electrical signals and a signal processor for determining the voltage based on an analysis of the output beams.

Davidson, James R.; Seifert, Gary D.

2003-09-16T23:59:59.000Z

36

Nuclear Energy Plant Optimization (NEPO) final report on aging and condition monitoring of low-voltage cable materials.  

SciTech Connect (OSTI)

This report summarizes results generated on a 5-year cable-aging program that constituted part of the Nuclear Energy Plant Optimization (NEPO) program, an effort cosponsored by the U. S. Department of Energy (DOE) and the Electric Power Research Institute (EPRI). The NEPO cable-aging effort concentrated on two important issues involving the development of better lifetime prediction methods as well as the development and testing of novel cable condition-monitoring (CM) techniques. To address improved life prediction methods, we first describe the use of time-temperature superposition principles, indicating how this approach improves the testing of the Arrhenius model by utilizing all of the experimentally generated data instead of a few selected and processed data points. Although reasonable superposition is often found, we show several cases where non-superposition is evident, a situation that violates the constant acceleration assumption normally used in accelerated aging studies. Long-term aging results over extended temperature ranges allow us to show that curvature in Arrhenius plots for elongation is a common occurrence. In all cases the curvature results in a lowering of the Arrhenius activation energy at lower temperatures implying that typical extrapolation of high temperature results over-estimates material lifetimes. The long-term results also allow us to test the significance of extrapolating through the crystalline melting point of semi-crystalline materials. By utilizing ultrasensitive oxygen consumption (UOC) measurements, we show that it is possible to probe the low temperature extrapolation region normally inaccessible to conventional accelerated aging studies. This allows the quantitative testing of the often-used Arrhenius extrapolation assumption. Such testing indicates that many materials again show evidence of ''downward'' curvature (E{sub a} values drop as the aging temperature is lowered) consistent with the limited elongation results and many literature results. It is also shown how the UOC approach allows the probing of temperatures that cross through the crystalline melting point region of semi-crystalline materials such as XLPO and EPR cable insulations. New results on combined environment aging of neoprene and hypalon cable jacketing materials are presented and offer additional evidence in support of our time-temperature-dose rate (t-T-DR) superposition approach that had been used successfully in the past for such situations.

Assink, Roger Alan; Gillen, Kenneth Todd; Bernstein, Robert

2005-11-01T23:59:59.000Z

37

Compact high voltage solid state switch  

DOE Patents [OSTI]

A compact, solid state, high voltage switch capable of high conduction current with a high rate of current risetime (high di/dt) that can be used to replace thyratrons in existing and new applications. The switch has multiple thyristors packaged in a single enclosure. Each thyristor has its own gate drive circuit that circuit obtains its energy from the energy that is being switched in the main circuit. The gate drives are triggered with a low voltage, low current pulse isolated by a small inexpensive transformer. The gate circuits can also be triggered with an optical signal, eliminating the trigger transformer altogether. This approach makes it easier to connect many thyristors in series to obtain the hold off voltages of greater than 80 kV.

Glidden, Steven C.

2003-09-23T23:59:59.000Z

38

Superconducting Cable Termination  

DOE Patents [OSTI]

Disclosed is a termination that connects high temperature superconducting (HTS) cable immersed in pressurized liquid nitrogen to high voltage and neutral (shield) external bushings at ambient temperature and pressure. The termination consists of a splice between the HTS power (inner) and shield (outer) conductors and concentric copper pipes which are the conductors in the termination. There is also a transition from the dielectric tape insulator used in the HTS cable to the insulators used between and around the copper pipe conductors in the termination. At the warm end of the termination the copper pipes are connected via copper braided straps to the conventional warm external bushings which have low thermal stresses. This termination allows for a natural temperature gradient in the copper pipe conductors inside the termination which enables the controlled flashing of the pressurized liquid coolant (nitrogen) to the gaseous state. Thus the entire termination is near the coolant supply pressure and the high voltage and shield cold bushings, a highly stressed component used in most HTS cables, are eliminated. A sliding seal allows for cable contraction as it is cooled from room temperature to ˜72-82 K. Seals, static vacuum, and multi-layer superinsulation minimize radial heat leak to the environment.

Sinha, Uday K. (Carrollton, GA); Tolbert, Jerry (Newnan, GA)

2005-08-30T23:59:59.000Z

39

Modular high voltage power supply for chemical analysis  

DOE Patents [OSTI]

A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2008-07-15T23:59:59.000Z

40

Modular high voltage power supply for chemical analysis  

SciTech Connect (OSTI)

A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2010-05-04T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Modular high voltage power supply for chemical analysis  

DOE Patents [OSTI]

A high voltage power supply for use in a system such as a microfluidics system, uses a DC--DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC--DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2007-01-09T23:59:59.000Z

42

High voltage overhead long transmission line design and fault analysis.  

E-Print Network [OSTI]

??The goal of this project is to design a reliable high voltage overhead long transmission line that satisfies specific design criteria including voltage regulation, efficiency,… (more)

Elzain, Mohamed Ali

2011-01-01T23:59:59.000Z

43

The US market for high-temperature superconducting wire in transmission cable applications  

SciTech Connect (OSTI)

Telephone interviews were conducted with 23 utility engineers concerning the future prospects for high-temperature superconducting (HTS) transmission cables. All have direct responsibility for transmission in their utility, most of them in a management capacity. The engineers represented their utilities as members of the Electric Power Research Institute`s Underground Transmission Task Force (which has since been disbanded). In that capacity, they followed the superconducting transmission cable program and are aware of the cryogenic implications. Nineteen of the 23 engineers stated the market for underground transmission would grow during the next decade. Twelve of those specified an annual growth rate; the average of these responses was 5.6%. Adjusting that figure downward to incorporate the remaining responses, this study assumes an average growth rate of 3.4%. Factors driving the growth rate include the difficulty in securing rights-of-way for overhead lines, new construction techniques that reduce the costs of underground transmission, deregulation, and the possibility that public utility commissions will allow utilities to include overhead costs in their rate base. Utilities have few plans to replace existing cable as preventive maintenance, even though much of the existing cable has exceeded its 40-year lifetime. Ten of the respondents said the availability of a superconducting cable with the same life-cycle costs as a conventional cable and twice the ampacity would induce them to consider retrofits. The respondents said a cable with those characteristics would capture 73% of their cable retrofits.

Forbes, D.

1996-04-01T23:59:59.000Z

44

Electro-optic high voltage sensor  

DOE Patents [OSTI]

A small sized electro-optic voltage sensor capable of accurate measurement of high levels of voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation into the sensor. A polarization beam displacer serves as a filter to separate the input beam into two beams with orthogonal linear polarizations. The beam displacer is oriented in such a way as to rotate the linearly polarized beams such that they enter a Pockels crystal having at a preferred angle of 45 degrees. The beam displacer is therefore capable of causing a linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels electro-optic effect induces a differential phase shift on the major and minor axes of the input beam as it travels through the Pockels crystal, which causes the input beam to be elliptically polarized. A reflecting prism redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization representing the major and minor axes. The system may include a detector for converting the output beams into electrical signals, and a signal processor for determining the voltage based on an analysis of the output beams. The output beams are amplitude modulated by the frequency of the electric field and the amplitude of the output beams is proportional to the magnitude of the electric field, which is related to the voltage being measured.

Davidson, James R. (Idaho Falls, ID); Seifert, Gary D. (Idaho Falls, ID)

2002-01-01T23:59:59.000Z

45

Structural Optimization of High Voltage Transmission Line Towers considering  

E-Print Network [OSTI]

Structural Optimization of High Voltage Transmission Line Towers considering Continuum and Discrete/or to common designs largely repeated (e.g. automotive compo- nents), and high voltage transmission towers can than conventional designs of high voltage transmission line towers. The optimization model proposed

Colominas, Ignasi

46

Safe epoxy encapsulant for high voltage magnetics  

SciTech Connect (OSTI)

This paper describes the use of Formula 456, an aliphatic amine cured epoxy for impregnating coils and high voltage transformers. Sandia has evaluated a number of MDA-free epoxy encapsulants which relied on either anhydride or other aromatic amine curing agents. The use of aliphatic amine curing agents was more recently evaluated and has resulted in the definition of Formula 456 resin. Methylene dianiline (MDA) has been used for more than 20 years as the curing agent for various epoxy formulations throughout the Department of Energy and much of industry. Sandia National Laboratories began the process of replacing MDA with other formulations because of regulations imposed by OSHA on the use of MDA. OSHA has regulated MDA because it is a suspect carcinogen. Typically the elimination of OSHA-regulated materials provides a rare opportunity to qualify new formulations in a range of demanding applications. It was important to take full advantage of that opportunity, although the associated materials qualification effort was costly. Small high voltage transformers are one of those demanding applications. The successful implementation of the new formulation for high reliability transformers will be described. The test results that demonstrate the parts are qualified for use in DOE weapon systems will be presented.

Sanchez, R.O.; Archer, W.E.

1998-01-01T23:59:59.000Z

47

A Charge Pump that Generates Negative High Voltage with Variable Voltage , Eugene Ivanova,  

E-Print Network [OSTI]

A Charge Pump that Generates Negative High Voltage with Variable Voltage Gain Jun Zhaob, , Eugene, Massachusetts 02115, U.S.A. Abstract A cross-coupled structure based charge pump that generates negative high. The proposed negative charge pump is designed to deliver 40 uA with a wide supply range from 2.5V to 5.5V using

Ayers, Joseph

48

Distributed Voltage and Current Control of Multi-Terminal High-Voltage Direct  

E-Print Network [OSTI]

}@kth.se.) Abstract: High-voltage direct current (HVDC) is a commonly used technology for long-distance power for multi-terminal HVDC (MTDC) systems is proposed. Under certain conditions on the controller gains factor behind long-distance power transmission. High-voltage direct current (HVDC) is a commonly used

Dimarogonas, Dimos

49

Cost-Effective Cable Insulation: Nanoclay Reinforced Ethylene-Propylene-Rubber for Low-Cost HVDC Cabling  

SciTech Connect (OSTI)

GENI Project: GE is developing new, low-cost insulation for high-voltage direct current (HVDC) electricity transmission cables. The current material used to insulate HVDC transmission cables is very expensive and can account for as much as 1/3 of the total cost of a high-voltage transmission system. GE is embedding nanomaterials into specialty rubber to create its insulation. Not only are these materials less expensive than those used in conventional HVDC insulation, but also they will help suppress excess charge accumulation. The excess charge left behind on a cable poses a major challenge for high-voltage insulation—if it’s not kept to a low level, it could ultimately lead the insulation to fail. GE’s low-cost insulation is compatible with existing U.S. cable manufacturing processes, further enhancing its cost effectiveness.

None

2012-02-24T23:59:59.000Z

50

Power superconducting power transmission cable  

DOE Patents [OSTI]

The present invention is for a compact superconducting power transmission cable operating at distribution level voltages. The superconducting cable is a conductor with a number of tapes assembled into a subconductor. These conductors are then mounted co-planarly in an elongated dielectric to produce a 3-phase cable. The arrangement increases the magnetic field parallel to the tapes thereby reducing ac losses.

Ashworth, Stephen P. (Cambridge, GB)

2003-01-01T23:59:59.000Z

51

INTERMODAL RESONANCE OF IN-PLANE FREE VIBRATIONS OF SUSPENDED CABLES  

E-Print Network [OSTI]

transmission lines for transport of high-voltage electricity are cables made of alu- minium alloy, suspended between high towers in the countryside. The part of a line that is suspended between two towers is called

Rienstra, Sjoerd W.

52

Nanoscale Morphological and Chemical Changes of High Voltage...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Nanoscale Morphological and Chemical Changes of High Voltage Lithium-Manganese Rich NMC Composite Cathodes with Cycling Friday, August 29, 2014 Renewable energy is critical for the...

53

High Voltage Electrolytes for Li-ion Batteries  

Broader source: Energy.gov (indexed) [DOE]

or otherwise restricted information High Voltage Electrolytes for Li-ion Batteries Vehicle Technologies Program 2 Overview * Start: Sep 2008 * End: Sep 2011 * 20 %...

54

Measurement of high voltage using Rutherford backscattering spectrometry  

E-Print Network [OSTI]

A novel variation of Rutherford Backscattering Spectrometry (RBS) has been utilized to measure a high voltage collected on an aluminum target by Direct Energy Conversion. The maximum high voltage on the target was measured to be 97.5 kV +/- 2 k...

Abrego, Celestino Pete

2007-04-25T23:59:59.000Z

55

Feasibility study of Nb3Al Rutherford cable for high field accelerator magnet application  

SciTech Connect (OSTI)

Feasibility study of Cu stabilized Nb{sub 3}Al strand and Rutherford cable for the application to high field accelerator magnets are being done at Fermilab in collaboration with NIMS. The Nb{sub 3}Al strand, which was developed and manufactured at NIMS in Japan, has a non-copper Jc of about 844 A/mm{sup 2} at 15 Tesla at 4.2 K, a copper content of 50%, and filament size of about 50 microns. Rutherford cables with 27 Nb{sub 3}Al strands of 1.03 mm diameter were fabricated and tested. Quench tests on a short cable were done to study its stability with only its self field, utilizing a high current transformer. A pair of 2 meter long Nb{sub 3}Al cables was tested extensively at CERN at 4.3 and 1.9 K up to 11 Tesla including its self field with a high transport current of 20.2 kA. In the low field test we observed instability near splices and in the central region. This is related to the flux-jump like behavior, because of excessive amount of Nb in the Nb{sub 3}Al strand. There is possibility that the Nb in Nb{sub 3}Al can cause instability below 2 Tesla field regions. We need further investigation on this problem. Above 8 Tesla, we observed quenches near the critical surface at fast ramp rate from 1000 to 3000 A/sec, with quench velocity over 100 m/sec. A small racetrack magnet was made using a 14 m of Rutherford cable and successfully tested up to 21.8 kA, corresponding to 8.7 T.

Yamada, R.; /Fermilab; Kikuchi, A.; /Tsukuba Magnet Lab.; Ambrosio, G.; Andreev, N.; Barzi, E.; Cooper, C.; Feher, S.; Kashikhin, V.V.; Lamm, M.; Novitski, I.; /Fermilab; Takeuchi, T.; /Tsukuba Magnet Lab.; Tartaglia, M.; Turrioni, D.; /Fermilab; Verweij, A.P.; /CERN; Wake, M.; Willering, G; /Tsukuba Magnet Lab.; Zlobin, A.V.; /Fermilab

2006-08-01T23:59:59.000Z

56

"Flexible aerogel as a superior thermal insulation for high temperature superconductor cable applications"  

SciTech Connect (OSTI)

High temperature superconducting (HTS) cables are an advanced technology that can both strengthen and improve the national electrical distribution infrastructure. HTS cables require sufficient cooling to overcome inherent low temperature heat loading. Heat loads are minimized by the use of cryogenic envelopes or cryostats. Cryostats require improvement in efficiency, reliability, and cost reduction to meet the demanding needs of HTS conductors (1G and 2G wires). Aspen Aerogels has developed a compression resistant aerogel thermal insulation package to replace compression sensitive multi-layer insulation (MLI), the incumbent thermal insulation, in flexible cryostats for HTS cables. Oak Ridge National Laboratory tested a prototype aerogel package in a lab-scale pipe apparatus to measure the rate of heat invasion. The lab-scale pipe test results of the aerogel solution will be presented and directly compared to MLI. A compatibility assessment of the aerogel material with HTS system components will also be presented. The aerogel thermal insulation solution presented will meet the demanding needs of HTS cables.

White, Shannon O. [Aspen Aerogel, Inc.; Demko, Jonathan A [ORNL; Tomich, A. [Aspen Aerogel, Inc.

2010-01-01T23:59:59.000Z

57

Living and Working Safely Around High-Voltage Power Lines.  

SciTech Connect (OSTI)

High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

United States. Bonneville Power Administration.

2001-06-01T23:59:59.000Z

58

Solid state safety jumper cables  

DOE Patents [OSTI]

Solid state jumper cables for connecting two batteries in parallel, having two bridge rectifiers for developing a reference voltage, a four-input decoder for determining which terminals are to be connected based on a comparison of the voltage at each of the four terminals to the reference voltage, and a pair of relays for effecting the correct connection depending on the determination of the decoder. No connection will be made unless only one terminal of each battery has a higher voltage than the reference voltage, indicating positive'' terminals, and one has a lower voltage than the reference voltage, indicating negative'' terminals, and that, therefore, the two high voltage terminals may be connected and the two lower voltage terminals may be connected. Current flows once the appropriate relay device is closed. The relay device is preferably a MOSFET (metal oxide semiconductor field effect transistor) combined with a series array of photodiodes that develop MOSFET gate-closing potential when the decoder output causes an LED to light.

Kronberg, J.W.

1993-02-23T23:59:59.000Z

59

Solid state safety jumper cables  

DOE Patents [OSTI]

Solid state jumper cables for connecting two batteries in parallel, having two bridge rectifiers for developing a reference voltage, a four-input decoder for determining which terminals are to be connected based on a comparison of the voltage at each of the four terminals to the reference voltage, and a pair of relays for effecting the correct connection depending on the determination of the decoder. No connection will be made unless only one terminal of each battery has a higher voltage than the reference voltage, indicating "positive" terminals, and one has a lower voltage than the reference voltage, indicating "negative" terminals, and that, therefore, the two high voltage terminals may be connected and the two lower voltage terminals may be connected. Current flows once the appropriate relay device is closed. The relay device is preferably a MOSFET (metal oxide semiconductor field effect transistor) combined with a series array of photodiodes that develop MOSFET gate-closing potential when the decoder output causes an LED to light.

Kronberg, James W. (353 Church Rd., Beech Island, SC 29841)

1993-01-01T23:59:59.000Z

60

Method and apparatus for electrical cable testing by pulse-arrested spark discharge  

DOE Patents [OSTI]

A method for electrical cable testing by Pulse-Arrested Spark Discharge (PASD) uses the cable response to a short-duration high-voltage incident pulse to determine the location of an electrical breakdown that occurs at a defect site in the cable. The apparatus for cable testing by PASD includes a pulser for generating the short-duration high-voltage incident pulse, at least one diagnostic sensor to detect the incident pulse and the breakdown-induced reflected and/or transmitted pulses propagating from the electrical breakdown at the defect site, and a transient recorder to record the cable response. The method and apparatus are particularly useful to determine the location of defect sites in critical but inaccessible electrical cabling systems in aging aircraft, ships, nuclear power plants, and industrial complexes.

Barnum, John R. (Albuquerque, NM); Warne, Larry K. (Albuquerque, NM); Jorgenson, Roy E. (Albuquerque, NM); Schneider, Larry X. (Albuquerque, NM)

2005-02-08T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

A Comparison of High-Voltage Switches  

SciTech Connect (OSTI)

This report summarizes our work on high-voltage switches during the past few years. With joint funding from the Department of Energy (DOE) and the Department of Defense (DOD), we tested a wide variety of switches to a common standard. This approach permitted meaningful comparisons between disparate switches. Most switches were purchased from commercial sources, though some were experimental devices. For the purposes of this report, we divided the switches into three generic types (gas, vacuum, and semiconductor) and selected data that best illustrates important strengths and weaknesses of each switch type. Test techniques that indicate the state of health of the switches are emphasized. For example, a good indicator of residual gas in a vacuum switch is the systematic variation of the switching delay in response to changes in temperature and/or operating conditions. We believe that the presentation of this kind of information will help engineers to select and to test switches for their particular applications. Our work was limited to switches capable of driving slappers. Also known as exploding-foil initiators, slappers are detonators that initiate a secondary explosive by direct impact with a small piece of matter moving at the detonation velocity (several thousands of meters per second). A slapper is desirable for enhanced safety (no primary explosive), but it also places extra demands on the capacitor-discharge circuit to deliver a fast-rising current pulse (greater than 10 A/ns) of several thousand amperes. The required energy is substantially less than one joule; but this energy is delivered in less than one microsecond, taking the peak power into the megawatt regime. In our study, the switches operated in the 1 kV to 3 kV range and were physically small, roughly 1 cm{sup 3} or less. Although a fuze functions only once in actual use, multiple-shot capability is important for production testing and for research work. For this reason, we restricted this report to multiple-shot switches. Furthermore, our work included only switches with submicrosecond timing precision, thereby excluding mechanical switches.

Chu, K.W.; Scott, G.L.

1999-02-01T23:59:59.000Z

62

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage put under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1996-01-01T23:59:59.000Z

63

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 figs.

Shimer, D.W.; Lange, A.C.

1996-10-15T23:59:59.000Z

64

Electrical system architecture having high voltage bus  

DOE Patents [OSTI]

An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

Hoff, Brian Douglas (East Peoria, IL); Akasam, Sivaprasad (Peoria, IL)

2011-03-22T23:59:59.000Z

65

High-voltage air-core pulse transformers  

SciTech Connect (OSTI)

General types of air core pulse transformers designed for high voltage pulse generation and energy transfer applications are discussed with special emphasis on pulse charging systems which operate up to the multi-megavolt range. The design, operation, dielectric materials, and performance are described. It is concluded that high voltage air core pulse transformers are best suited to applications outside the normal ranges of conventional magnetic core transformers. In general these include charge transfer at high power levels and fast pulse generation with comparatively low energy. When properly designed and constructed, they are capable of delivering high energy transfer efficiency and have demonstrated superior high voltage endurance. The principal disadvantage of high voltage air core transformers is that they are not generally available from commercial sources. Consequently, the potential user must become thoroughly familiar with all aspects of design, fabrication and system application before he can produce a high performance transformer system. (LCL)

Rohwein, G. J.

1981-01-01T23:59:59.000Z

66

High Voltage Electrolyte for Lithium Batteries  

Broader source: Energy.gov (indexed) [DOE]

5.0E-04 1.0E-03 2 2.2 2.4 2.6 2.8 Voltage (V) dQdV (AhV) 1 st Charge 1.2M LiPF 6 ECEMC 37 1 st Charge 1.0M LiPF 6 TMS1NM3 55 with 2% and 4% VC 1 st Charge 1.0M LiPF 6 TMS...

67

Optically triggered high voltage switch network and method for switching a high voltage  

DOE Patents [OSTI]

An optically triggered solid state switch and method for switching a high voltage electrical current. A plurality of solid state switches (350) are connected in series for controlling electrical current flow between a compensation capacitor (112) and ground in a reactive power compensator (50, 50') that monitors the voltage and current flowing through each of three distribution lines (52a, 52b and 52c), which are supplying three-phase power to one or more inductive loads. An optical transmitter (100) controlled by the reactive power compensation system produces light pulses that are conveyed over optical fibers (102) to a switch driver (110') that includes a plurality of series connected optical triger circuits (288). Each of the optical trigger circuits controls a pair of the solid state switches and includes a plurality of series connected resistors (294, 326, 330, and 334) that equalize or balance the potential across the plurality of trigger circuits. The trigger circuits are connected to one of the distribution lines through a trigger capacitor (340). In each switch driver, the light signals activate a phototransistor (300) so that an electrical current flows from one of the energy reservoir capacitors through a pulse transformer (306) in the trigger circuit, producing gate signals that turn on the pair of serially connected solid state switches (350).

El-Sharkawi, Mohamed A. (Renton, WA); Andexler, George (Everett, WA); Silberkleit, Lee I. (Mountlake Terrace, WA)

1993-01-19T23:59:59.000Z

68

Characterization of a high-temperature superconducting conductor on round core cables in magnetic fields up to 20 T  

SciTech Connect (OSTI)

The next generation of high-field magnets that will operate at magnetic fields substantially above 20 T, or at temperatures substantially above 4.2 K, requires high-temperature superconductors (HTS). Conductor on round core (CORC) cables, in which RE-Ba{sub 2}Cu{sub 3}O{sub 7-{delta}} (RE = rare earth) (REBCO) coated conductors are wound in a helical fashion on a fl?exible core, are a practical and versatile HTS cable option for low-inductance, high-field magnets. We performed the first tests of CORC magnet cables in liquid helium in magnetic fields of up to 20 T. A record critical current I{sub c} of 5021 A was measured at 4.2 K and 19 T. In a cable with an outer diameter of 7.5 mm, this value corresponds to an engineering current density J{sub e} of 114 A mm{sup -2} , the highest J{sub e} ever reported for a superconducting cable at such high magnetic fields. Additionally, the first magnet wound from an HTS cable was constructed from a 6 m-long CORC cable. The 12-turn, double-layer magnet had an inner diameter of 9 cm and was tested in a magnetic field of 20 T, at which it had an I{sub c} of 1966 A. The cables were quenched repetitively without degradation during the measurements, demonstrating the feasibility of HTS CORC cables for use in high-field magnet applications.

van der Laan, Danko [Advanced Conductor Technologies; Noyes, Patrick [National High Magnetic Field Laboratory; Miller, George [National High Magnetic Field Laboratory; Weijers, Hubertus [National High Magnetic Field Laboratory; Willering, Gerard [CERN

2013-02-13T23:59:59.000Z

69

Semiconductor Bridge Cable Test  

SciTech Connect (OSTI)

The semiconductor bridge (SCB) is an electroexplosive device used to initiate detonators. A C cable is commonly used to connect the SCB to a firing set. A series of tests were performed to identify smaller, lighter cables for firing single and multiple SCBs. This report provides a description of these tests and their results. It was demonstrated that lower threshold voltages and faster firing times can be achieved by increasing the wire size, which reduces ohmic losses. The RF 100 appears to be a reasonable substitute for C cable when firing single SCBs. This would reduce the cable volume by 68% and the weight by 67% while increasing the threshold voltage by only 22%. In general, RG 58 outperforms twisted pair when firing multiple SCBs in parallel. The RG 58's superior performance is attributed to its larger conductor size.

KING, TONY L.

2002-01-01T23:59:59.000Z

70

Unravelling the Performance Degradation Mechanisms in High-voltage...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Unravelling the Performance Degradation Mechanisms in High-voltage Lithium-ion Battery Composite Oxide Electrodes Apr 11 2014 02:00 PM - 03:00 PM Debasish Mohanty, ORNL, Oak Ridge...

71

Abstract--This paper discusses modelling of high voltage AC underground cables. For long cables, when crossbonding points  

E-Print Network [OSTI]

is with Manitoba HVDC Research Centre, R3J 3W1 Winnipeg, Canada (e-mail: Jeewantha@hvdc.ca ) C. L. Bak

Bak, Claus Leth

72

High voltage electrical amplifier having a short rise time  

DOE Patents [OSTI]

A circuit, comprising an amplifier and a transformer is disclosed that produces a high power pulse having a fast response time, and that responds to a digital control signal applied through a digital-to-analog converter. The present invention is suitable for driving a component such as an electro-optic modulator with a voltage in the kilovolt range. The circuit is stable at high frequencies and during pulse transients, and its impedance matching circuit matches the load impedance with the output impedance. The preferred embodiment comprises an input stage compatible with high-speed semiconductor components for amplifying the voltage of the input control signal, a buffer for isolating the input stage from the output stage; and a plurality of current amplifiers connected to the buffer. Each current amplifier is connected to a field effect transistor (FET), which switches a high voltage power supply to a transformer which then provides an output terminal for driving a load. The transformer comprises a plurality of transmission lines connected to the FETs and the load. The transformer changes the impedance and voltage of the output. The preferred embodiment also comprises a low voltage power supply for biasing the FETs at or near an operational voltage.

Christie, David J. (Pleasanton, CA); Dallum, Gregory E. (Livermore, CA)

1991-01-01T23:59:59.000Z

73

Planar LTCC transformers for high voltage flyback converters: Part II.  

SciTech Connect (OSTI)

This paper is a continuation of the work presented in SAND2007-2591 'Planar LTCC Transformers for High Voltage Flyback Converters'. The designs in that SAND report were all based on a ferrite tape/dielectric paste system originally developed by NASCENTechnoloy, Inc, who collaborated in the design and manufacturing of the planar LTCC flyback converters. The output/volume requirements were targeted to DoD application for hard target/mini fuzing at around 1500 V for reasonable primary peak currents. High voltages could be obtained but with considerable higher current. Work had begun on higher voltage systems and is where this report begins. Limits in material properties and processing capabilities show that the state-of-the-art has limited our practical output voltage from such a small part volume. In other words, the technology is currently limited within the allowable funding and interest.

Schofield, Daryl (NASCENTechnology, Inc., Watertown, SD); Schare, Joshua M., Ph.D.; Slama, George (NASCENTechnology, Inc., Watertown, SD); Abel, David (NASCENTechnology, Inc., Watertown, SD)

2009-02-01T23:59:59.000Z

74

Design & Fabrication of a High-Voltage Photovoltaic Cell  

SciTech Connect (OSTI)

Silicon photovoltaic (PV) cells are alternative energy sources that are important in sustainable power generation. Currently, applications of PV cells are limited by the low output voltage and somewhat low efficiency of such devices. In light of this fact, this project investigates the possibility of fabricating high-voltage PV cells on float-zone silicon wafers having output voltages ranging from 50 V to 2000 V. Three designs with different geometries of diffusion layers were simulated and compared in terms of metal coverage, recombination, built-in potential, and conduction current density. One design was then chosen and optimized to be implemented in the final device design. The results of the simulation serve as a feasibility test for the design concept and provide supportive evidence of the effectiveness of silicon PV cells as high-voltage power supplies.

Felder, Jennifer; /North Carolina State U. /SLAC

2012-09-05T23:59:59.000Z

75

Design issues for high voltage converters for ion engines  

SciTech Connect (OSTI)

A design strategy is presented for a power converter for a high voltage ion engine for a spacecraft application. Various design issues such as appropriate topologies and control methods are considered. In this particular instance it was determined that a full bridge converter with phase shift gating and voltage mode control provided an efficient system with a minimum of electromagnetic interference. This system can be implemented in a straightforward manner, and it is relatively easy to protect from faults at the output.

King, R.J.; Stuart, T.A. [Univ. of Toledo, OH (United States)

1995-12-31T23:59:59.000Z

76

Cable Diagnostic Focused Initiative  

SciTech Connect (OSTI)

This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online knowledge based system (KBS) that helps utilities select the most effective diagnostic technologies for a given cable circuit and circuit conditions.

Hartlein, R.A.; Hampton, R.N.

2010-12-30T23:59:59.000Z

77

High Temperature, High Voltage Fully Integrated Gate Driver Circuit  

Broader source: Energy.gov (indexed) [DOE]

driver circuit, 5-V on- chip voltage regulator, short-circuit protection, undervoltage lockout, bootstrap capacitor, dead time controller and temperature sensor * 0.8-micron,...

78

HIGH-VOLTAGE SPINEL AND POLYANION CATHODES  

Broader source: Energy.gov (indexed) [DOE]

ordering, segregation of cations to the surface, Mn 3+ content, morphology, and synthesisprocessing methodsconditions), and use the understanding to develop high-performance,...

79

The commercial development of water repellent coatings for high voltage transmission lines  

SciTech Connect (OSTI)

The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.

Hunter, Scott Robert [ORNL

2013-10-01T23:59:59.000Z

80

The commercial development of water repellent coatings for high voltage transmission lines  

SciTech Connect (OSTI)

The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy?s Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.

Hunter, S. R. [ORNL] [ORNL; Daniel, A. [Southwire Company] [Southwire Company

2013-10-31T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360{degree}/n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load. 7 figs.

Shimer, D.W.; Lange, A.C.

1997-03-11T23:59:59.000Z

82

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1997-01-01T23:59:59.000Z

83

Gaseous insulators for high voltage electrical equipment  

DOE Patents [OSTI]

Gaseous insulators comprise compounds having high attachment cross sections for electrons having energies in the 0-1.3 electron volt range. Multi-component gaseous insulators comprise compounds and mixtures having overall high electron attachment cross sections in the 0-1.3 electron volt range and moderating gases having high cross sections for inelastic interactions with electrons of energies 1-4 electron volts. Suitable electron attachment components include hexafluorobutyne, perfluorobutene-2, perfluorocyclobutane, perfluorodimethylcyclobutane, perfluorocyclohexene, perfluoromethylcyclohexane, hexafluorobutadiene, perfluoroheptene-1 and hexafluoroazomethane. Suitable moderating gases include N.sub.2, CO, CO.sub.2 and H.sub.2. The gaseous insulating mixture can also contain SF.sub.6, perfluoropropane and perfluorobenzene.

Christophorou, Loucas G. (Oak Ridge, TN); James, David R. (Knoxville, TN); Pace, Marshall O. (Knoxville, TN); Pai, Robert Y. (Concord, TN)

1981-01-01T23:59:59.000Z

84

High voltage stability performance of a gamma ray detection device  

SciTech Connect (OSTI)

An industrial grade digital radiation survey meter device is currently being developed at Malaysian Nuclear Agency. This device used a cylindrical type Geiger Mueller (GM) which acts as a detector. GM detector operates at relatively high direct current voltages depend on the type of GM tube. This thin/thick walled cylindrical type of GM tube operates at 450-650 volts range. Proper value and stability performance of high voltage are important parameters to ensure that this device give a reliable radiation dose measurement. This paper will present an assessment of the stability and performance of the high voltage supply for radiation detector. The assessment is performed using System Identification tools box in MATLAB and mathematical statistics.

Abdullah, Nor Arymaswati; Lombigit, Lojius; Rahman, Nur Aira Abd [Technical Support Division, Malaysian Nuclear Agency, 43000 Kajang, Selangor (Malaysia)

2014-02-12T23:59:59.000Z

85

Radio-Frequency Interference (RFI) From Extra-High-Voltage (EHV) Transmission Lines  

E-Print Network [OSTI]

-current (HVAC) transmission lines; high-voltage direct-current (HVDC) transmission lines will be addressed

Ellingson, Steven W.

86

Triaxial HTS Cable for the AEP Bixby Project  

SciTech Connect (OSTI)

Ultera has installed a single 200-meter long high temperature superconducting (HTS) 3-phase triaxial design cable at the American Electric Power (AEP) Bixby substation in Columbus, Ohio. The cable connects a 132/13.8 kV transformer to the distribution switchgear serving seven outgoing circuits. It was designed to carry 3000 Arms. Testing of 3- to 5-meter length prototype cables, including a 5-meter prototype with full scale terminations tested at ORNL was conducted prior to the manufacture and installation of the AEP triaxial cable. These prototypes were used to demonstrate the crucial operating conditions including steady state operation at the 3000 Arms design current, high voltage operation, high voltage withstand and 110 kV impulse, and overcurrent fault capability. A summary of the results from the thermal analysis and testing conducted by Ultera and ORNL will be presented. Some analysis of the cable thermal-hydraulic response based on the testing that were used to determine some of the cable cryogenic system requirements are also presented.

Demko, Jonathan A [ORNL; Gouge, Michael J [ORNL; Lindsay, David T [ORNL; Roden, Mark L [ORNL; Tolbert, Jerry Carlton [ORNL

2007-01-01T23:59:59.000Z

87

Current isolating epitaxial buffer layers for high voltage photodiode array  

DOE Patents [OSTI]

An array of photodiodes in series on a common semi-insulating substrate has a non-conductive buffer layer between the photodiodes and the semi-insulating substrate. The buffer layer reduces current injection leakage between the photodiodes of the array and allows optical energy to be converted to high voltage electrical energy.

Morse, Jeffrey D. (Martinez, CA); Cooper, Gregory A. (Pleasant Hill, CA)

2002-01-01T23:59:59.000Z

88

Field Optimization of Three Dimensional High Voltage C. Trinitis  

E-Print Network [OSTI]

Field Optimization of Three Dimensional High Voltage Equipment C. Trinitis Lehrstuhl f The goal of finding an optimal electric field strength distribution for arbitrary three di­ mensional­ cal optimization algorithm. The package ob­ tained from these three components is then able

Stamatakis, Alexandros

89

High Voltage DC Transmission 1.0 Introduction  

E-Print Network [OSTI]

1 High Voltage DC Transmission 1.0 Introduction HVDC has been applied in electric power systems for many years now. Figure 1 illustrates worldwide many of the HVDC applications [1]. Fig. 1 ABB provides a webpage which summarizes HVDC projects by type and capacity or by commissioning year [2]. Wikipedia [3

McCalley, James D.

90

High Voltage DC Transmission 2 1.0 Introduction  

E-Print Network [OSTI]

1 High Voltage DC Transmission 2 1.0 Introduction Interconnecting HVDC within an AC system requires on use of switching devices collectively referred to in the HVDC community as valves. Valves may be non. Fig. 1 There have been three types of devices for implementing HVDC converter circuits: mercury

McCalley, James D.

91

Superconductor cable  

DOE Patents [OSTI]

A superconductor cable is described, having a superconductive flexible cable core (1) , which is laid in a cryostat (2, 3, 4), in which the cable core (1) runs in the cryostat (2, 3, 4) in the form of a wave or helix at room temperature.

Allais, Arnaud; Schmidt, Frank; Marzahn, Erik

2010-05-04T23:59:59.000Z

92

High voltage dc--dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.

Shimer, D.W.; Lange, A.C.

1995-05-23T23:59:59.000Z

93

High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1995-01-01T23:59:59.000Z

94

Switch contact device for interrupting high current, high voltage, AC and DC circuits  

DOE Patents [OSTI]

A high voltage switch contact structure capable of interrupting high voltage, high current AC and DC circuits. The contact structure confines the arc created when contacts open to the thin area between two insulating surfaces in intimate contact. This forces the arc into the shape of a thin sheet which loses heat energy far more rapidly than an arc column having a circular cross-section. These high heat losses require a dramatic increase in the voltage required to maintain the arc, thus extinguishing it when the required voltage exceeds the available voltage. The arc extinguishing process with this invention is not dependent on the occurrence of a current zero crossing and, consequently, is capable of rapidly interrupting both AC and DC circuits. The contact structure achieves its high performance without the use of sulfur hexafluoride.

Via, Lester C.; Witherspoon, F. Douglas; Ryan, John M.

2005-01-04T23:59:59.000Z

95

Advanced Gate Drive for the SNS High Voltage Converter Modulator  

SciTech Connect (OSTI)

SLAC National Accelerator Laboratory is developing a next generation H-bridge switch plate [1], a critical component of the SNS High Voltage Converter Modulator [2]. As part of that effort, a new IGBT gate driver has been developed. The drivers are an integral part of the switch plate, which are essential to ensuring fault-tolerant, high-performance operation of the modulator. The redesigned driver improves upon the existing gate drive in several ways. The new gate driver has improved fault detection and suppression capabilities; suppression of shoot-through and over-voltage conditions, monitoring of dI/dt and Vce(sat) for fast over-current detection and suppression, and redundant power isolation are some of the added features. In addition, triggering insertion delay is reduced by a factor of four compared to the existing driver. This paper details the design and performance of the new IGBT gate driver. A simplified schematic and description of the construction are included. The operation of the fast over-current detection circuits, active IGBT over-voltage protection circuit, shoot-through prevention circuitry, and control power isolation breakdown detection circuit are discussed.

Nguyen, M.N.; Burkhart, C.; Kemp, M.A.; /SLAC; Anderson, D.E.; /Oak Ridge

2009-05-07T23:59:59.000Z

96

High Power, High Voltage FETs in Linear Applications: A User's Perspective  

SciTech Connect (OSTI)

The specifications of the current crop of highpower, high-voltage field-effect transistors (FETs) can lure a designer into employing them in high-voltage DC equipment. Devices with extremely low on-resistance and very high power ratings are available from several manufacturers. However, our experience shows that high-voltage, linear operation of these devices at near-continuous duty can present difficult reliability challenges at stress levels well-below their published specifications. This paper chronicles the design evolution of a 600 volt, 8 ampere shunt regulator for use with megawatt-class radio transmitters, and presents a final design that has met its reliability criteria.

N. Greenough, E. Fredd, S. DePasquale

2009-09-21T23:59:59.000Z

97

Distribution System Voltage Performance Analysis for High-Penetration Photovoltaics  

SciTech Connect (OSTI)

This report examines the performance of commonly used distribution voltage regulation methods under reverse power flow.

Liu, E.; Bebic, J.

2008-02-01T23:59:59.000Z

98

Experimental validation of a high voltage pulse measurement method.  

SciTech Connect (OSTI)

This report describes X-cut lithium niobate's (LiNbO3) utilization for voltage sensing by monitoring the acoustic wave propagation changes through LiNbO3 resulting from applied voltage. Direct current (DC), alternating current (AC) and pulsed voltage signals were applied to the crystal. Voltage induced shift in acoustic wave propagation time scaled quadratically for DC and AC voltages and linearly for pulsed voltages. The measured values ranged from 10 - 273 ps and 189 ps - 2 ns for DC and non-DC voltages, respectively. Data suggests LiNbO3 has a frequency sensitive response to voltage. If voltage source error is eliminated through physical modeling from the uncertainty budget, the sensor's U95 estimated combined uncertainty could decrease to ~0.025% for DC, AC, and pulsed voltage measurements.

Cular, Stefan; Patel, Nishant Bhupendra; Branch, Darren W.

2013-09-01T23:59:59.000Z

99

Milligram-Scale High-Voltage Power Electronics for Piezoelectric Microrobots  

E-Print Network [OSTI]

, the generation of high voltages for HMF actu- ators requires voltage conversion circuits with step-up ratios to the voltage step-up functionality, the power electronics circuitry must generate a time-varying signal ranging from 50 to 100. While there are a number of circuit topologies with high step-up ratios, many

Wood, Robert

100

An Approximate Dynamic Programming Algorithm for the Allocation of High-Voltage Transformer Spares in the  

E-Print Network [OSTI]

An Approximate Dynamic Programming Algorithm for the Allocation of High-Voltage Transformer Spares high-voltage transformer spares throughout the electric grid to mitigate the risk of random transformer-voltage transformers are an integral part of the electric transmission system. A catas- trophic transformer failure

Powell, Warren B.

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

High-voltage atmospheric breakdown across intervening rutile dielectrics.  

SciTech Connect (OSTI)

This report documents work conducted in FY13 on electrical discharge experiments performed to develop predictive computational models of the fundamental processes of surface breakdown in the vicinity of high-permittivity material interfaces. Further, experiments were conducted to determine if free carrier electrons could be excited into the conduction band thus lowering the effective breakdown voltage when UV photons (4.66 eV) from a high energy pulsed laser were incident on the rutile sample. This report documents the numerical approach, the experimental setup, and summarizes the data and simulations. Lastly, it describes the path forward and challenges that must be overcome in order to improve future experiments for characterizing the breakdown behavior for rutile.

Williamson, Kenneth Martin; Simpson, Sean; Coats, Rebecca Sue; Jorgenson, Roy Eberhardt; Hjalmarson, Harold Paul; Pasik, Michael Francis

2013-09-01T23:59:59.000Z

102

High Temperature, High Voltage Fully Integrated Gate Driver Circuit |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensional Subject:Ground Hawaii HIGH PERFORMANCE andHighWells |

103

Superconductor cable  

DOE Patents [OSTI]

A superconductor cable includes a superconductive cable core (1) and a cryostat (2) enclosing the same. The cable core (1) has a superconductive conductor (3), an insulation (4) surrounding the same and a shielding (5) surrounding the insulation (4). A layer (3b) of a dielectric or semiconducting material is applied to a central element (3a) formed from a normally conducting material as a strand or tube and a layer (3c) of at least one wire or strip of superconductive material is placed helically on top. The central element (3a) and the layer (3c) are connected to each other in an electrically conducting manner at the ends of the cable core (1).

Allais, Arnaud (Hannover, DE); Schmidt, Frank (Langenhagen, DE

2009-12-15T23:59:59.000Z

104

High Temperature, High Voltage Fully Integrated Gate Driver Circuit |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensional Subject:Ground Hawaii HIGH PERFORMANCE andHighWells |Department

105

Voltage spike detection in high field superconducting accelerator magnets  

SciTech Connect (OSTI)

A measurement system for the detection of small magnetic flux changes in superconducting magnets, which are due to either mechanical motion of the conductor or flux jump, has been developed at Fermilab. These flux changes are detected as small amplitude, short duration voltage spikes, which are {approx}15mV in magnitude and lasts for {approx}30 {micro}sec. The detection system combines an analog circuit for the signal conditioning of two coil segments and a fast data acquisition system for digitizing the results, performing threshold detection, and storing the resultant data. The design of the spike detection system along with the modeling results and noise analysis will be presented. Data from tests of high field Nb{sub 3}Sn magnets at currents up to {approx}20KA will also be shown.

Orris, D.F.; Carcagno, R.; Feher, S.; Makulski, A.; Pischalnikov, Y.M.; /Fermilab

2004-12-01T23:59:59.000Z

106

Effect of high-voltage nanosecond pulses on complex plasmas  

SciTech Connect (OSTI)

Influence of high-voltage (1-11 kV) pulses of nanosecond (20 ns) duration on microparticles levitating in a rf plasma is studied. It is shown that the pulses produce significant influence on the plasma, causing perturbations with the relaxation time of the order of 10{sup -4} s. This time is sufficient for the microparticle to acquire significant kinetic energy. Application of repetitive pulses leads to the vertical oscillations of the microparticles. Clusters, consisting of small number of microparticles, exhibit parametric instabilities of horizontal modes under the effect of repetitive pulses. It was shown that the parametric instability is caused by the vertical oscillations of the microparticles in the nonuniform environment of the sheath.

Pustylnik, M. Y.; Ivlev, A. V.; Thomas, H. M.; Morfill, G. E. [Max-Planck-Institut fuer Extraterrestrische Physik, Giessenbachstrasse, 85741 Garching (Germany); Vasilyak, L. M.; Vetchinin, S. P.; Polyakov, D. N.; Fortov, V. E. [Joint Institute for High Temperatures, Russian Academy of Sciences, Izhorskaya 13/19, 125412 Moscow (Russian Federation)

2009-11-15T23:59:59.000Z

107

High-speed, sub-pull-in voltage MEMS switching.  

SciTech Connect (OSTI)

We have proposed and demonstrated MEMS switching devices that take advantage of the dynamic behavior of the MEMS devices to provide lower voltage actuation and higher switching speeds. We have explored the theory behind these switching techniques and have demonstrated these techniques in a range of devices including MEMS micromirror devices and in-plane parallel plate MEMS switches. In both devices we have demonstrated switching speeds under one microsecond which has essentially been a firm limit in MEMS switching. We also developed low-loss silicon waveguide technology and the ability to incorporate high-permittivity dielectric materials with MEMS. The successful development of these technologies have generated a number of new projects and have increased both the MEMS switching and optics capabilities of Sandia National Laboratories.

Spahn, Olga Blum; Brewer, Steven; Olsson, Roy H.; Bogart, Gregory R.; Luck, David L.; Watts, Michael R.; Shaw, Michael J.; Nielson, Gregory N.; Resnick, Paul James; Tigges, Christopher P.; Grossetete, Grant David

2008-01-01T23:59:59.000Z

108

Summary of multiterminal high-voltage direct current transmission technology  

SciTech Connect (OSTI)

This report summarizes the present state of multiterminal (MT) high-voltage direct current (HVDC) power transmission. The purpose is to reassess the need for HVDC circuit breakers and to identify needed research for MT HVDC. The fundamentals of this technology are presented, and previous research and development is reviewed. Although no MT HVDC systems have yet been built, many concepts have been proposed. Some require a dc breaker, and others do not. Both options have advantages and disadvantages for various applications, so the selection will depend on the proposed application. Research is needed to define operating characteristics of various MT HVDC systems. In some applications, dc breakers will be useful, so research into HVDC interruption should continue. Also, dc fault detection and control algorithms for MT systems should be studied.

Biggs, R.B.; Jewell, W.T.

1984-05-01T23:59:59.000Z

109

Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power Filter Applications  

E-Print Network [OSTI]

Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power voltage-source inverters connected in series (known as cascaded hybrid asymmetric multilevel inverter scheme is developed to allow the operation of the inverter modules at different voltages and switching

Catholic University of Chile (Universidad Católica de Chile)

110

Control of Analyte Electrolysis in Electrospray Ionization Mass Spectrometry Using Repetitively Pulsed High Voltage  

SciTech Connect (OSTI)

Analyte electrolysis using a repetitively pulsed high voltage ion source was investigated and compared to that using a regular, continuously operating direct current high voltage ion source in electrospray ionization mass spectrometry. The extent of analyte electrolysis was explored as a function of the length and frequency of the high voltage pulse using the model compound reserpine in positive ion mode. Using +5 kV as the maximum high voltage amplitude, reserpine was oxidized to its 2, 4, 6 and 8-electron oxidation products when direct current high voltage was employed. In contrast, when using a pulsed high voltage, oxidation of reserpine was eliminated by employing the appropriate high voltage pulse length and frequency. This effect was caused by inefficient mass transport of the analyte to the electrode surface during the duration of the high voltage pulse and the subsequent relaxation of the emitter electrode/ electrolyte interface during the time period when the high voltage was turned off. This mode of ESI source operation allows for analyte electrolysis to be quickly and simply switched on or off electronically via a change in voltage pulse variables.

Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

2011-01-01T23:59:59.000Z

111

High voltage power supply with modular series resonant inverters  

DOE Patents [OSTI]

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360.degree./n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit.

Dreifuerst, Gary R. (Livermore, CA); Merritt, Bernard T. (Livermore, CA)

1995-01-01T23:59:59.000Z

112

High voltage power supply with modular series resonant inverters  

DOE Patents [OSTI]

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360{degree}/n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit. 11 figs.

Dreifuerst, G.R.; Merritt, B.T.

1995-07-18T23:59:59.000Z

113

Design, conditioning, and performance of a high voltage, high brightness dc photoelectron gun with variable gap  

SciTech Connect (OSTI)

A new high voltage photoemission gun has been constructed at Cornell University which features a segmented insulator and a movable anode, allowing the cathode-anode gap to be adjusted. In this work, we describe the gun's overall mechanical and high voltage design, the surface preparation of components, as well as the clean construction methods. We present high voltage conditioning data using a 50 mm cathode-anode gap, in which the conditioning voltage exceeds 500 kV, as well as at smaller gaps. Finally, we present simulated emittance results obtained from a genetic optimization scheme using voltage values based on the conditioning data. These results indicate that for charges up to 100 pC, a 30 mm gap at 400 kV has equal or smaller 100% emittance than a 50 mm gap at 450 kV, and also a smaller core emittance, when placed as the source for the Cornell energy recovery linac photoinjector with bunch length constrained to be <3 ps rms. For 100 pC up to 0.5 nC charges, the 50 mm gap has larger core emittance than the 30 mm gap, but conversely smaller 100% emittance.

Maxson, Jared; Bazarov, Ivan; Dunham, Bruce; Dobbins, John; Liu, Xianghong; Smolenski, Karl [Cornell Laboratory for Accelerator-Based Sciences and Education, Cornell University, Ithaca, New York 14853 (United States)

2014-09-15T23:59:59.000Z

114

Theory and practice of dynamic voltage/frequency scaling in the high performance computing environment.  

E-Print Network [OSTI]

?? This dissertation provides a comprehensive overview of the theory and practice of Dynamic Voltage/Frequency Scaling (DVFS) in the High Performance Computing (HPC) environment. We… (more)

Rountree, Barry Louis

2010-01-01T23:59:59.000Z

115

Princeton Power Systems (TRL 5 6 Component) - Marine High-Voltage...  

Broader source: Energy.gov (indexed) [DOE]

Princeton Power Systems (TRL 5 6 Component) - Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage Princeton Power Systems (TRL 5 6...

116

High frequency AC power converter for low voltage circuits  

E-Print Network [OSTI]

This thesis presents a novel AC power delivery architecture that is suitable for VHF frequency (50-100MHz) polyphase AC/DC power conversion in low voltage integrated circuits. A complete AC power delivery architecture was ...

Salazar, Nathaniel Jay Tobias

2012-01-01T23:59:59.000Z

117

Radio-frequency powered glow discharge device and method with high voltage interface  

DOE Patents [OSTI]

A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components.

Duckworth, Douglas C. (Knoxville, TN); Marcus, R. Kenneth (Clemson, SC); Donohue, David L. (Vienna, AT); Lewis, Trousdale A. (Oak Ridge, TN)

1994-01-01T23:59:59.000Z

118

Radio-frequency powered glow discharge device and method with high voltage interface  

DOE Patents [OSTI]

A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components. 11 figures.

Duckworth, D.C.; Marcus, R.K.; Donohue, D.L.; Lewis, T.A.

1994-06-28T23:59:59.000Z

119

Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions  

E-Print Network [OSTI]

Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 19-1 High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 1. DC Properties of Modern Filled Epoxy Insulation Academic and Research Staff Dr. Chathan Cooke Sponsor

120

Evaluation of Insulation Systems for the Optimal Design of High Voltage Pulse Transformers  

E-Print Network [OSTI]

This paper presents a study for the design of the insulation systems of high voltage pulse transformer based on experimental tests and numerical simulations. Data of high voltage tests on solid and liquid insulation materials are presented and discussed. The understanding of each part of the insulation is supported by electrostatic fields simulations.

Sylvain, Candolfi; Davide, Aguglia; Philippe, Viarouge; Jürgen, Biela; Jerome, Cros

2015-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Superconducting Cable  

DOE Patents [OSTI]

In order to provide a flexible oxide superconducting cable which is reduced in AC loss, tape-shaped superconducting wires covered with a stabilizing metal are wound on a flexible former. The superconducting wires are preferably laid on the former at a bending strain of not more than 0.2%. In laying on the former, a number of tape-shaped superconducting wires are laid on a core member in a side-by-side manner, to form a first layer. A prescribed number of tape-shaped superconducting wires are laid on top of the first layer in a side-by-side manner, to form a second layer. The former may be made of a metal, plastic, reinforced plastic, polymer, or a composite and provides flexibility to the superconducting wires and the cable formed therewith.

Hughey, Raburn L. (Franklin, GA); Sinha, Uday K. (Carrollton, GA); Reece, David S. (Carrollton, GA); Muller, Albert C. (Eidson, TN)

2005-07-22T23:59:59.000Z

122

Superconducting Cable  

DOE Patents [OSTI]

In order to provide a flexible oxide superconducting cable which is reduced in AC loss, tape-shaped superconducting wires covered with a stabilizing metal are wound on a flexible former. The superconducting wires are preferably laid on the former at a bending strain of not more than 0.2%. In laying on the former, a number of tape-shaped superconducting wires are laid on a core member in a side-by-side manner, to form a first layer. A prescribed number of tape-shaped superconducting wires are laid on top of the first layer in a side-by-side manner, to form a second layer. The former may be made of a metal, plastic, reinforced plastic, polymer, or a composite and provides flexibility to the superconducting wires and the cable formed therewith.

Hughey, Raburn L. (Franklin, GA); Sinha, Uday K. (Carrollton, GA); Reece, David S. (Carrollton, GA); Muller, Albert C. (Eidson, TN)

2005-03-08T23:59:59.000Z

123

High voltage bus and auxiliary heater control system for an electric or hybrid vehicle  

DOE Patents [OSTI]

A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

Murty, Balarama Vempaty (West Bloomfield, MI)

2000-01-01T23:59:59.000Z

124

Voltage Sequence Control Based High-Current Rectifier System  

E-Print Network [OSTI]

of transformer. A passive filter is added at the primary side to achieve power factor improvement over the range of output voltage. This scheme is optimized to determine optimum turns ratio of the transformer and optimum not enforce unity power factor operation and guidelines provided by harmonic standards such as IEEE-519

Paderborn, Universität

125

Dielectric-wall linear accelerator with a high voltage fast rise time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators  

DOE Patents [OSTI]

A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface. 12 figs.

Caporaso, G.J.; Sampayan, S.E.; Kirbie, H.C.

1998-10-13T23:59:59.000Z

126

Impact of High Wind Penetration on the Voltage Profile of Distribution Systems  

E-Print Network [OSTI]

of wind generator the voltage of the system may become lower than acceptable voltage level due and wind generator is presented. Simulation results are given in Section III which shows the impact of high--In this paper, simulation results showing the effect of lower and higher penetration of distributed wind

Pota, Himanshu Roy

127

Capacitor discharge process for welding braided cable  

DOE Patents [OSTI]

A capacitor discharge process for welding a braided cable formed from a plurality of individual cable strands to a solid metallic electrically conductive member comprises the steps of: (a) preparing the electrically conductive member for welding by bevelling one of its end portions while leaving an ignition projection extending outwardly from the apex of the bevel; (b) clamping the electrically conductive member in a cathode fixture; (c) connecting the electrically conductive member clamped in the cathode fixture to a capacitor bank capable of being charged to a preselected voltage value; (d) preparing the braided cable for welding by wrapping one of its end portions with a metallic sheet to form a retaining ring operable to maintain the individual strands of the braided cable in fixed position within the retaining ring; (e) clamping the braided cable and the retaining ring as a unit in an anode fixture so that the wrapped end portion of the braided cable faces the ignition projection of the electrically conductive member; and (f) moving the cathode fixture towards the anode fixture until the ignition projection of the electrically conductive member contacts the end portion of the braided cable thereby allowing the capacitor bank to discharge through the electrically conductive member and through the braided cable and causing the electrically conductive member to be welded to the braided cable via capacitor discharge action.

Wilson, Rick D. (Corvallis, OR)

1995-01-01T23:59:59.000Z

128

High voltage ignition of high pressure microwave powered UV light sources  

SciTech Connect (OSTI)

Industrial microwave powered (electrodeless) light sources have been limited to quiescent pressures of {approximately}300 Torr of buffer gas and metal-halide fills. The predominant reason for such restrictions has been the inability to microwave ignite the plasma due to the collisionality of higher pressure fills and/or the electronegativity of halide bulb chemistries. Commercially interesting bulb fills require electric fields for ionization that are often large multiples of the breakdown voltage for air. Many auxiliary ignition methods are evaluated for efficiency and practicality before the choice of a high-voltage system with a retractable external electrode. The scheme utilizes a high voltage pulse power supply and a novel field emission source. Acting together they create localized condition of pressure reduction and high free electron density. This allows the normal microwave fields to drive this small region into avalanche, ignite the bulb, and heat the plasma to its operating point (T{sub e} {approx} 0.5 eV). This process is currently being used in a new generation of lamps, which are using multi-atmospheric excimer laser chemistries and pressure and constituent enhanced metal-halide systems. At the present time, production prototypes produce over 900 W of radiation in a 30 nm band, centered at 308 nm. Similarly, these prototypes when loaded with metal-halide bulb fills produce over 1 kW of radiation in 30 nm wide bands, centered about the wavelength of interest.

Frank, J.D.; Cekic, M.; Wood, C.H. [Fusion U.V. Curing Systems Corp., Gaithersburg, MD (United States)

1997-12-31T23:59:59.000Z

129

High-voltage crowbar protection for the large CDF axial drift chamber  

SciTech Connect (OSTI)

The Central Outer Tracker (COT) is a big cylindrical drift chamber that provides charged particle tracking for the Collider Detector at Fermilab experiment. To protect the COT, the large stored energy in the high voltage system needs to be removed quickly when a problem is sensed. For the high voltage switch, a special-order silicon-controlled-rectifier was chosen over more readily available integrated gate bipolar transistors because of layout and reliability questions. The considerations concerning the high voltage switch, the prototype performance, and the experience of more than two years of running are described.

Binkley, M.; Mukherjee, A.; Stuermer, W.; Wagner, R.L.; /Fermilab

2004-01-01T23:59:59.000Z

130

Light-weight DC to very high voltage DC converter  

DOE Patents [OSTI]

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current.

Druce, Robert L. (Union City, CA); Kirbie, Hugh C. (Dublin, CA); Newton, Mark A. (Livermore, CA)

1998-01-01T23:59:59.000Z

131

Light-weight DC to very high voltage DC converter  

DOE Patents [OSTI]

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current. 1 fig.

Druce, R.L.; Kirbie, H.C.; Newton, M.A.

1998-06-30T23:59:59.000Z

132

Princeton Power Systems (TRL 5 6 Component)- Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage  

Broader source: Energy.gov [DOE]

Princeton Power Systems (TRL 5 6 Component) - Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage

133

Vehicle Technologies Office Merit Review 2014: High-Voltage Solid Polymer Batteries for Electric Drive Vehicles  

Broader source: Energy.gov [DOE]

Presentation given by Seeo, Inc. at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about high-voltage solid polymer...

134

Current mode integrators and their applications in low-voltage high frequency CMOS signal processing  

E-Print Network [OSTI]

Low voltage CMOS fully differential integrators for high frequency continuous-time filters using current-mode techniques are presented.. Current mode techniques are employed to avoid the use of the floating differential pair, in order to achieve...

Smith, Sterling Lane

1993-01-01T23:59:59.000Z

135

Voltage-dependent calcium channels and currents in native neurons and other cells have been divided into high voltage  

E-Print Network [OSTI]

Voltage-dependent calcium channels and currents in native neurons and other cells have been divided than one subtype of channel. A new subfamily of voltage-dependent calcium channel á1 subunit genes. 1999), having four domains, each with a voltage sensor and a pore-forming P loop. However

Dolphin, Annette C.

136

Low Voltage High Precision Spatial Light ModulatorsFinal Report  

SciTech Connect (OSTI)

The goal of this project was to make LLNL a leader in Spatial Light Modulators (SLMs) by developing the technology that will be needed by the next generation of SLMs. We would use new lower voltage actuators and bond those actuators directly to controlling circuitry to break the fundamental limitations that constrain current SLM technology. This three-year project was underfunded in the first year and not funded in the second year. With the funding that was available, we produced actuators and designs for the controlling circuitry that would have been integrated in the second year. Spatial light modulators (SLMs) are arrays of tiny movable mirrors that modulate the wave-fronts of light. SLMs can correct aberrations in incoming light for adaptive optics or modulate light for beam control, optical communication and particle manipulation. MicroElectroMechanical Systems (MEMS) is a technology that utilizes the microfabrication tools developed by the semiconductor industry to fabricate a wide variety of tiny machines. The first generation of MEMS SLMs have improved the functionality of SLMs while drastically reducing per pixel cost making arrays on the order of 1000 pixels readily available. These MEMS SLMs however are limited by the nature of their designs to be very difficult to scale above 1000 pixels and have very limited positioning accuracy. By co-locating the MEMS mirrors with CMOS electronics, we will increase the scalability and positioning accuracy. To do this we will have to make substantial advances in SLM actuator design, and fabrication.

Papavasiliou, A P

2005-02-09T23:59:59.000Z

137

TPWRD-00683-2009 1 Abstract--With the increasing use of high-voltage AC cables at  

E-Print Network [OSTI]

System Operator, Energinet.dk. F. F. da Silva is a PhD student at the Institute of Energy Technology of Energy Technology, Aalborg University, 9220 Aalborg, Denmark (e-mail: clb@iet.aau.dk). U. S. Gudmundsdottir is a PhD student at the Institute of Energy Technology, Aalborg University, 9220 Aalborg, Denmark

Silva, Filipe Faria Da

138

Cable Measuring Engine Operation Procedures  

E-Print Network [OSTI]

gov CABLE MEASURING ENGINE OPERATION PROCEDURES LBNL-40565LBNL-40565 CABLE MEASURING ENGINE OPERATION PROCEDURES INDEXThe Cable Measuring Engine (CME) is a tool which measures

Authors, Various

2011-01-01T23:59:59.000Z

139

Testing of High Voltage Surge Protection Devices for Use in Liquid Argon TPC Detectors  

E-Print Network [OSTI]

In this paper we demonstrate the capability of high voltage varistors and gas discharge tube arrestors for use as surge protection devices in liquid argon time projection chamber detectors. The insulating and clamping behavior of each type of device is characterized in air (room temperature), and liquid argon (90~K), and their robustness under high voltage and high energy surges in cryogenic conditions is verified. The protection of vulnerable components in liquid argon during a 150 kV high voltage discharge is also demonstrated. Each device is tested for argon contamination and light emission effects, and both are constrained to levels where no significant impact upon liquid argon time projection chamber functionality is expected. Both devices investigated are shown to be suitable for HV surge protection applications in cryogenic detectors.

J. Asaadi; J. M. Conrad; S. Gollapinni; B. J. P. Jones; H. Jostlein; J. M. St. John; T. Strauss; S. Wolbers; J. Zennamo

2014-06-23T23:59:59.000Z

140

Connecting Renewables Directly to the Grid: Resilient Multi-Terminal HVDC Networks with High-Voltage High-Frequency Electronics  

SciTech Connect (OSTI)

GENI Project: GE is developing electricity transmission hardware that could connect distributed renewable energy sources, like wind farms, directly to the grid—eliminating the need to feed the energy generated through intermediate power conversion stations before they enter the grid. GE is using the advanced semiconductor material silicon carbide (SiC) to conduct electricity through its transmission hardware because SiC can operate at higher voltage levels than semiconductors made out of other materials. This high-voltage capability is important because electricity must be converted to high-voltage levels before it can be sent along the grid’s network of transmission lines. Power companies do this because less electricity is lost along the lines when the voltage is high.

None

2012-01-23T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

The design, construction, and operation of long-distance high-voltage electricity transmission technologies.  

SciTech Connect (OSTI)

This report focuses on transmission lines, which operate at voltages of 115 kV and higher. Currently, the highest voltage lines comprising the North American power grid are at 765 kV. The grid is the network of transmission lines that interconnect most large power plants on the North American continent. One transmission line at this high voltage was built near Chicago as part of the interconnection for three large nuclear power plants southwest of the city. Lines at this voltage also serve markets in New York and New England, also very high demand regions. The large power transfers along the West Coast are generally at 230 or 500 kV. Just as there are practical limits to centralization of power production, there are practical limits to increasing line voltage. As voltage increases, the height of the supporting towers, the size of the insulators, the distance between conductors on a tower, and even the width of the right-of-way (ROW) required increase. These design features safely isolate the electric power, which has an increasing tendency to arc to ground as the voltage (or electrical potential) increases. In addition, very high voltages (345 kV and above) are subject to corona losses. These losses are a result of ionization of the atmosphere, and can amount to several megawatts of wasted power. Furthermore, they are a local nuisance to radio transmission and can produce a noticeable hum. Centralized power production has advantages of economies of scale and special resource availability (for instance, hydro resources), but centralized power requires long-distance transfers of power both to reach customers and to provide interconnections for reliability. Long distances are most economically served at high voltages, which require large-scale equipment and impose a substantial footprint on the corridors through which power passes. The most visible components of the transmission system are the conductors that provide paths for the power and the towers that keep these conductors at a safe distance from each other and from the ground and the natural and built environment. Common elements that are generally less visible (or at least more easily overlooked) include the maintained ROW along the path of the towers, access roads needed for maintenance, and staging areas used for initial construction that may be restored after construction is complete. Also visible but less common elements along the corridor may include switching stations or substations, where lines of similar or different voltages meet to transfer power.

Molburg, J. C.; Kavicky, J. A.; Picel, K. C.

2008-03-03T23:59:59.000Z

142

Effect of Trapping on the Critical Voltage for Degradation in GaN High Electron Mobility Transistors  

E-Print Network [OSTI]

conditions, UV illumination decreases the critical voltage for the onset of degradation in gate current in Ga traps in the fresh state. Keywords­ GaN HEMTs, critical voltage, degradation, UV illuminationEffect of Trapping on the Critical Voltage for Degradation in GaN High Electron Mobility

del Alamo, Jesús A.

143

High Voltage Electrolyte for Lithium Batteries | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensional Subject:Ground Hawaii HIGH PERFORMANCEDOE Biomass Program Review2

144

High Voltage Electrolyte for Lithium Batteries | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensional Subject:Ground Hawaii HIGH PERFORMANCEDOE Biomass Program

145

Method of making high breakdown voltage semiconductor device  

DOE Patents [OSTI]

A semiconductor device having at least one P-N junction and a multiple-zone junction termination extension (JTE) region which uniformly merges with the reverse blocking junction is disclosed. The blocking junction is graded into multiple zones of lower concentration dopant adjacent termination to facilitate merging of the JTE to the blocking junction and placing of the JTE at or near the high field point of the blocking junction. Preferably, the JTE region substantially overlaps the graded blocking junction region. A novel device fabrication method is also provided which eliminates the prior art step of separately diffusing the JTE region.

Arthur, Stephen D. (Scotia, NY); Temple, Victor A. K. (Jonesville, NY)

1990-01-01T23:59:59.000Z

146

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles  

SciTech Connect (OSTI)

The purpose of this project was for Seeo to develop a high energy lithium based technology with targets of over 500 Wh/l and 325 Wh/kg. Seeo would leverage the work already achieved with its unique proprietary solid polymer DryLyteTM technology in cells which had a specific energy density of 220 Wh/kg. The development work was focused on establishing a dual electrolyte system, coated cathode particle techniques, various types of additives, and different conductive salts. The program had a duration of three years, with Seeo delivering the final cells at the end of 2014 for evaluation by a DOE laboratory.

Eitouni, Hany; Yang, Jin; Pratt, Russell; Wang, Xiao; Grape, Ulrik

2014-09-29T23:59:59.000Z

147

Dual design resistor for high voltage conditioning and transmission lines  

DOE Patents [OSTI]

A dual resistor for eliminating the requirement for two different value resistors. The dual resistor includes a conditioning resistor at a high resistance value and a run resistor at a low resistance value. The run resistor can travel inside the conditioning resistor. The run resistor is capable of being advanced by a drive assembly until an electrical path is completed through the run resistor thereby shorting out the conditioning resistor and allowing the lower resistance run resistor to take over as the current carrier.

Siggins, Timothy Lynn (Newport News, VA); Murray, Charles W. (Hayes, VA); Walker, Richard L. (Norfolk, VA)

2007-01-23T23:59:59.000Z

148

Optimizing performance per watt on GPUs in High Performance Computing: temperature, frequency and voltage effects  

E-Print Network [OSTI]

The magnitude of the real-time digital signal processing challenge attached to large radio astronomical antenna arrays motivates use of high performance computing (HPC) systems. The need for high power efficiency (performance per watt) at remote observatory sites parallels that in HPC broadly, where efficiency is an emerging critical metric. We investigate how the performance per watt of graphics processing units (GPUs) is affected by temperature, core clock frequency and voltage. Our results highlight how the underlying physical processes that govern transistor operation affect power efficiency. In particular, we show experimentally that GPU power consumption grows non-linearly with both temperature and supply voltage, as predicted by physical transistor models. We show lowering GPU supply voltage and increasing clock frequency while maintaining a low die temperature increases the power efficiency of an NVIDIA K20 GPU by up to 37-48% over default settings when running xGPU, a compute-bound code used in radio...

Price, D C; Barsdell, B R; Babich, R; Greenhill, L J

2014-01-01T23:59:59.000Z

149

Design and validation of a high-voltage levitation circuit for electrostatic accelerometers  

SciTech Connect (OSTI)

A simple high-voltage circuit with a voltage range of 0 to 900 V and an open-loop bandwidth of 11 kHz is realized by using an operational amplifier and a MOSFET combination. The circuit is used for the levitation of a test mass of 71 g, suspended below the top-electrodes with a gap distance of 57 ?m, so that the performance of an electrostatic accelerometer can be tested on the ground. The translation noise of the accelerometer, limited by seismic noise, is about 4 × 10{sup ?8} m/s{sup 2}/Hz{sup 1/2} at 0.1 Hz, while the high-voltage coupling noise is one-order of magnitude lower.

Li, G.; Wu, S. C.; Zhou, Z. B.; Bai, Y. Z.; Hu, M.; Luo, J. [MOE Key Laboratory of Fundamental Physical Quantities Measurements, School of Physics, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China)] [MOE Key Laboratory of Fundamental Physical Quantities Measurements, School of Physics, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China)

2013-12-15T23:59:59.000Z

150

Static reactive power compensators for high-voltage power systems. Final report  

SciTech Connect (OSTI)

A study conducted to summarize the role of static reactive power compensators for high voltage power system applications is described. This information should be useful to the utility system planning engineer in applying static var systems (SVS) to high voltage as (HVAC) systems. The static var system is defined as a form of reactive power compensator. The general need for reactive power compensation in HVAC systems is discussed, and the static var system is compared to other devices utilized to provide reactive power compensation. Examples are presented of applying SVS for specific functions, such as the prevention of voltage collapse. The operating principles of commercially available SVS's are discussed in detail. The perormance and active power loss characteristics of SVS types are compared.

Not Available

1981-04-01T23:59:59.000Z

151

Apparatus for injecting high power laser light into a fiber optic cable  

DOE Patents [OSTI]

High intensity laser light is evenly injected into an optical fiber by the combination of a converging lens and a multisegment kinoform (binary optical element). The segments preferably have multi-order gratings on each which are aligned parallel to a radial line emanating from the center of the kinoform and pass through the center of the element. The grating in each segment causes circumferential (lateral) dispersion of the light, thereby avoiding detrimental concentration of light energy within the optical fiber.

Sweatt, William C. (Albuquerque, NM)

1997-01-01T23:59:59.000Z

152

Dual Low Voltage IC Based High and Low Side Yan Yin, Regan Zane  

E-Print Network [OSTI]

drivers are required in most switching power converters to provide on/off control of both ground referenced and floating switches. The drivers are required to provide sufficient current to the gates to meet and low-side gate drivers; dual low voltage ICs; capacitive coupling; charge pump I. INTRODUCTION High

153

The powerful high-voltage glow discharge electron gun and power unit on its base  

SciTech Connect (OSTI)

The technical and operational characteristics and features of powerful electron gun with cold cathodes on the basis of high-voltage glow discharge (HGD) are submitted. The systems, ensuring their work are described. Some results of operation and applications of these non-traditional electron guns are presented.

Chernov, V.A. [All-Russian Electrotechnical Institute, Moscow (Russian Federation)

1994-12-31T23:59:59.000Z

154

An earth-isolated optically coupled wideband high voltage probe powered by ambient light  

E-Print Network [OSTI]

(2012) Optimized working conditions for a thermoelectric generator as a topping cycle for gas turbines J (2012) Feasibility study in application of forging waste heat on absorption cooling system J. Renewable-emitting diode that converts high voltage into an amplitude-modulated optical signal, which is then conveyed

Bellan, Paul M.

155

Realizing high-voltage thin film lateral bipolar transistors on SOI with a collector-tub  

E-Print Network [OSTI]

Realizing high-voltage thin film lateral bipolar transistors on SOI with a collector-tub Sukhendu-dimensional device simulation to examine the effect of a collector tub on the collector breakdown of the SOI based BJTs. This method involves creating a collector tub by etching the buried oxide followed by an n

Kumar, M. Jagadesh

156

Interconnected High-Voltage Pulsed-Power Converters System Design for H? Ion Sources  

E-Print Network [OSTI]

This paper presents the design and experimental validations of a system of three new high-voltage (HV) pulsedpower converters for the H? sources. The system requires three pulsed voltages (50, 40, and 25 kV to ground) at 2-Hz repetition rate, for 700 ?s of usable flat-top. The solution presents ripplefree output voltages and minimal stored energy to protect the ion source from the consequences of arc events. Experimental results on the final full-scale prototype are presented. In case of short-circuit events, the maximal energy delivered to the source is in the Joule range. HV flat-top stability of 1% is experimentally achieved with a simple Proportional-Integral- Derivative regulation and preliminary tuned H? source (e.g., radio frequency control, gas injection, and so forth). The system is running since more than a year with no power converter failures and damage to the source.

Aguglia, D

2014-01-01T23:59:59.000Z

157

Effect of high solenoidal magnetic fields on breakdown voltages of high vacuum 805 MHz cavities  

SciTech Connect (OSTI)

There is an on going international collaboration studying the feasibility and cost of building a muon collider or neutrino factory [1,2]. An important aspect of this study is the full understanding of ionization cooling of muons by many orders of magnitude for the collider case. An important muon ionization cooling experiment, MICE [3], has been proposed to demonstrate and validate the technology that could be used for cooling. Ionization cooling is accomplished by passing a high-emittance muon beam alternately through regions of low Z material, such as liquid hydrogen, and very high accelerating RF Cavities within a multi-Tesla solenoidal field. To determine the effect of very large solenoidal magnetic fields on the generation of dark current, x-rays and on the breakdown voltage gradients of vacuum RF cavities, a test facility has been established at Fermilab in Lab G. This facility consists of a 12 MW 805 MHz RF station and a large warm bore 5 T solenoidal superconducting magnet containing a pill box type cavity with thin removable window apertures. This system allows dark current and breakdown studies of different window configurations and materials. The results of this study will be presented. The study has shown that the peak achievable accelerating gradient is reduced by a factor greater than 2 when solenoidal field of greater than 2 T are applied to the cavity.

Moretti, A.; Bross, A.; Geer, S.; Qian, Z.; /Fermilab; Norem, J.; /Argonne; Li, D.; Zisman, M.; /LBL, Berkeley; Torun, Y.; /IIT, Chicago; Rimmer, R.; /Jefferson Lab; Errede,; /Illinois U., Urbana

2005-10-01T23:59:59.000Z

158

Electronically controlled cable wrapper  

DOE Patents [OSTI]

A spindle assembly engages and moves along a length of cable to be wrapped with insulating tape. Reels of insulating tape are mounted on a outer rotatable spindle which revolves around the cable to dispense insulating tape. The rate of movement of the spindle assembly along the length of the cable is controlled by a stepper motor which is programmably synchronized to the rate at which rotatable spindle wraps the cable. The stepper motor drives a roller which engages the cable and moves the spindle assembly along the length of the cable as it is being wrapped. The spindle assembly is mounted at the end of an articulated arm which allows free movement of the spindle assembly and allows the spindle assembly to follow lateral movement of the cable.

Young, T.M.

1982-08-17T23:59:59.000Z

159

Outages of electric power supply resulting from cable failures Boston Edison Company system  

SciTech Connect (OSTI)

Factual data are provided regarding 5 electric power supply interruptions that occurred in the Boston Metropolitan area during April to June, 1979. Common to all of these outages was the failure of an underground cable as the initiating event, followed by multiple equipment failures. There was significant variation in the voltage ratings and types of cables which failed. The investigation was unable to delineate a single specific Boston Edison design operating or maintenance practice that could be cited as the cause of the outages. After reviewing the investigative report the following actions were recommended: the development and implementation of a plan to eliminate the direct current cable network; develop a network outage restoration plan; regroup primary feeder cables wherever possible to minimize the number of circuits in manholes, and to separate feeders to high load density areas; develop a program to detect incipient cable faults; evaluate the separation of the north and south sections of Back Bay network into separate networks; and, as a minimum, install the necessary facilities to make it possible to re-energize one section without interfering with the other; and re-evaluate the cathodic protection scheme where necessary. (LCL)

None

1980-07-01T23:59:59.000Z

160

Using Dielectric Losses to De-Ice Power Transmission Lines with 100 kHz High-Voltage  

E-Print Network [OSTI]

Using Dielectric Losses to De-Ice Power Transmission Lines with 100 kHz High-Voltage Excitation J DIELECTRIC LOSSES TO DE-ICE POWER TRANSMISSION LINES . . . 1 Using Dielectric Losses to De-Ice Power Transmission Lines with 100 kHz High-Voltage Excitation Joshua D. McCurdy, Charles R. Sullivan and Victor F

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

CABLE TECHNOLOGY LABORATORIES, INC. DETERMINATION OF THRESHOLD...  

Office of Scientific and Technical Information (OSTI)

Aged Polymeric Dielectric Cable TABLE OF CONTENTS ABSTRACT INTRODUCTION DESCRIPTION OF TEST CABLES TEMPERATURE CONDITIONING OF TEST CABLES TESTING OF XLPE INSULATED CABLE BEFORE...

162

Cable Measuring Engine Operation Procedures  

SciTech Connect (OSTI)

The Cable Measuring Engine (CME) is a tool which measures and records the cable dimensions in a nondestructive fashion. It is used in-line with the superconductor cable as it is being made. The CME is intended to be used as a standard method of measuring cable by the various manufacturers involved in the cable process.

Authors, Various

1997-07-11T23:59:59.000Z

163

Round-robin artificial contamination test on high voltage dc insulators  

SciTech Connect (OSTI)

This paper summarizes the results of a worldwide round-robin test of high voltage dc (HVDC) insulators, which was carried out in six laboratories aiming at standardization of the method for artificial contamination tests on HVDC insulators. Flashover characteristics of three kinds of specimens were evaluated by the clean fog and the salt fog procedures. Sufficient information is now available to allow the preparation of provisional international specifications for artificial contamination testing of HVDC insulators.

Naito, K.; Schneider, H.M.

1995-07-01T23:59:59.000Z

164

Marine High Voltage Power Conditioning and Transmission System with Integrated Storage DE-EE0003640 Final Report  

SciTech Connect (OSTI)

Design, Development, and test of the three-port power converter for marine hydrokinetic power transmission. Converter provides ports for AC/DC conversion of hydrokinetic power, battery storage, and a low voltage to high voltage DC port for HVDC transmission to shore. The report covers the design, development, implementation, and testing of a prototype built by PPS.

Frank Hoffmann, PhD; Aspinall, Rik

2012-12-10T23:59:59.000Z

165

Novel Nonflammable Electrolytes for Secondary Magnesium Batteries and High Voltage Electrolytes for Electrochemcial Supercapacitors  

SciTech Connect (OSTI)

Magnesium has been used successfully in primary batteries, but its use in rechargeable cells has been stymied by the lack of suitable non-aqueous electrolyte that can conduct Mg+2 species, combined with poor stripping and plating properties. The development of a suitable cathode material for rechargeable magnesium batteries has also been a roadblock, but a nonflammable electrolyte is key. Likewise, the development of safe high voltage electrochemical supercapaitors has been stymied by the use of flammable solvents in the liquid electrolyte; to wit, acetonitrile. The purpose of the research conducted in this effort was to identify useful compositions of magnesium salts and polyphosphate solvents that would enable magnesium ions to be cycled within a secondary battery design. The polyphosphate solvents would provide the solvent for the magnesium salts while preventing the electrolyte from being flammable. This would enable these novel electrolytes to be considered as an alternative to THF-based electrolytes. In addition, we explored several of these solvents together with lithium slats for use as high voltage electrolytes for carbon-based electrochemical supercapacitors. The research was successful in that: 1) Magnesium imide dissolved in a phosphate ester solvent that contains a halogented phosphate ester appears to be the preferred electrolyte for a rechargeable Mg cell. 2) A combination of B-doped CNTs and vanadium phosphate appear to be the cathode of choice for a rechargeable Mg cell by virtue of higher voltage and better reversibility. 3) Magnesium alloys appear to perform better than pure magnesium when used in combination with the novel polyphosphate electrolytes. Also, this effort has established that Phoenix Innovationâ??s family of phosphonate/phosphate electrolytes together with specific lithium slats can be used in supercapacitor systems at voltages of greater than 10V.

Dr. Brian Dixon

2008-12-30T23:59:59.000Z

166

A new class of high force, low-voltage, compliant actuation system  

SciTech Connect (OSTI)

Although many actuators employing electrostatic comb drives have been demonstrated in a laboratory environment, widespread acceptance in mass produced microelectromechanical systems (MEMS) may be limited due to issues associated with low drive force, large real estate demands, high operating voltages, and reliability concerns due to stiction. On the other hand, comb drives require very low drive currents, offer predictable response, and are highly compatible with the fabrication technology. The expand the application space and facilitate the widespread deployment of self-actuated MEMS, a new class of advanced actuation systems has been developed that maintains the highly desirable aspects of existing components, while significantly diminishing the issues that could impede large scale acceptance. In this paper, the authors will present low-voltage electrostatic actuators that offer a dramatic increase in force over conventional comb drive designs. In addition, these actuators consume only a small fraction of the chip area previously used, yielding significant gains in power density. To increase the stroke length of these novel electrostatic actuators, the authors have developed highly efficient compliant stroke amplifiers. The coupling of compact, high-force actuators with fully compliant displacement multipliers sets a new paradigm for highly integrated microelectromechanical systems.

RODGERS,M. STEVEN; KOTA,SRIDHAR; HETRICK,JOEL; LI,ZHE; JENSEN,BRIAN D.; KRYGOWSKI,THOMAS W.; MILLER,SAMUEL L.; BARNES,STEPHEN MATTHEW; BURG,MICHAEL STANLEY

2000-04-10T23:59:59.000Z

167

Multistrand superconductor cable  

DOE Patents [OSTI]

Improved multistrand Rutherford-type superconductor cable is produced by using strands which are preformed, prior to being wound into the cable, so that each strand has a variable cross section, with successive portions having a substantially round cross section, a transitional oval cross section, a rectangular cross section, a transitional oval cross section, a round cross section and so forth, in repetitive cycles along the length of the strand. The cable is wound and flattened so that the portions of rectangular cross section extend across the two flat sides of the cable at the strand angle. The portions of round cross section are bent at the edges of the flattened cable, so as to extend between the two flat sides. The rectangular portions of the strands slide easily over one another, so as to facilitate flexing and bending of the cable, while also minimizing the possibility of causing damage to the strands by such flexing or bending. Moreover, the improved cable substantially maintains its compactness and cross-sectional shape when the cable is flexed or bent.

Borden, Albert R. (El Cerrito, CA)

1985-01-01T23:59:59.000Z

168

Multistrand superconductor cable  

DOE Patents [OSTI]

Improved multistrand Rutherford-type superconductor cable is produced by using strands which are preformed, prior to being wound into the cable, so that each strand has a variable cross section, with successive portions having a substantially round cross section, a transitional oval cross section, a rectangular cross section, a transitional oval cross section, a round cross section and so forth, in repetitive cycles along the length of the strand. The cable is wound and flattened so that the portions of rectangular cross section extend across the two flat sides of the cable at the strand angle. The portions of round cross section are bent at the edges of the flattened cable, so as to extend between the two flat sides. The rectangular portions of the strands slide easil

Borden, A.R.

1984-03-08T23:59:59.000Z

169

DC BUFFERING AND FLOATING CURRENT FOR A HIGH VOLTAGE IMB APPLICATION  

SciTech Connect (OSTI)

An interface technique for the latest generation of the Impedance Measurement Box (IMB) has been conceived to enable measurement of impedance spectra for battery modules up to 300V. A 300V capable or higher IMB is an enabling technology for in-situ diagnostics within electric vehicle charging stations or battery back-ups within power distribution sub-stations. It is possible that the existing IMB can be adapted via a 300V interface module to a test battery with voltage significantly greater than 50V. Recently a new concept was conceived for the calibration, algorithm and electronics of the IMB. That algorithm and calibration for that concept have been physically validated. The principal feature of the new electronics is the floating current source excitation of the battery under test. The single ended current excitation of the battery under test, used in the 50V IMB, requires that the negative terminal of the test battery must be the analog ground for the IMB. The new floating current technique allows the test battery to be fully high impedance isolated for a measurement. That isolation will improve IMB noise immunity and enable interrogation of cells internal to a battery module. All these techniques still use the same rapid concept for impedance measurement with the IMB. The purpose of this disclosure is to provide an overview of the analytical validation for three concepts to interface the floating current excitation to a high voltage battery. Recursive simulation models were used in different test scenarios to validate the various new concepts. The analysis will show that it is possible to interface the floating signal current to obtain an impedance measurement on a high voltage test battery. Additionally, the analysis will investigate stress seen by electronics while testing a 300V battery.

J.L. Morrison

2014-08-01T23:59:59.000Z

170

A design for a high voltage magnet coil ringer test set  

SciTech Connect (OSTI)

By discharging a bank of charged capacitors through a high power SCR switch into an SSC dipole magnet assembly, it is possible to ``ring`` the coil and develop a voltage stress of greater than 50 volts turn-to-turn, thereby verifying the insulation integrity. We will present an overview of the test set design for a 2 kV isolated SCR firing circuit, including safety features, selectable capacitor banks, and digital waveform storage system. Results from testing typical coils and magnets will be included. Possible upgrades are also discussed.

Koska, W. [Fermi National Accelerator Lab., Batavia, IL (United States); Sims, R.E. [Superconducting Super Collider Lab., Dallas, TX (United States)

1992-04-01T23:59:59.000Z

171

A design for a high voltage magnet coil ringer test set  

SciTech Connect (OSTI)

By discharging a bank of charged capacitors through a high power SCR switch into an SSC dipole magnet assembly, it is possible to ring'' the coil and develop a voltage stress of greater than 50 volts turn-to-turn, thereby verifying the insulation integrity. We will present an overview of the test set design for a 2 kV isolated SCR firing circuit, including safety features, selectable capacitor banks, and digital waveform storage system. Results from testing typical coils and magnets will be included. Possible upgrades are also discussed.

Koska, W. (Fermi National Accelerator Lab., Batavia, IL (United States)); Sims, R.E. (Superconducting Super Collider Lab., Dallas, TX (United States))

1992-04-01T23:59:59.000Z

172

A Fusing Switch for Fault Suppression in the SNS High Voltage Converter Modulators  

SciTech Connect (OSTI)

The High Voltage Converter Modulators (HVCMs) at the Spallation Neutron Source (SNS) have operated in excess of a combined 250,000 hours. Performance and reliability improvements to the HVCM are ongoing to increase modulator availability as accelerator system demands increase. There is a relatively large amount of energy storage in the HVCMs, {approx}180 kJ. This energy has the potential to dump into unsuppressed faults, cause damage, and increase the time to repair. The 'fusing switch' concept involves isolation of this stored energy from the location of the most common faults. This paper introduces this concept and its application to the HVCMs.

Kemp, Mark A.; Burkhart, Craig; Nguyen, Minh N.; /SLAC; Anderson, David E.; /Oak Ridge

2009-08-03T23:59:59.000Z

173

A high voltage test stand for electron gun qualification for LINACs  

SciTech Connect (OSTI)

An electron gun lest stand has been developed at RRCAT. The test stand consists of a high voltage pulsed power supply, electron gun filament supply, grid supply, UHV system and electron gun current measurement system. Several electron guns developed indigenously were evaluated on this test stand. The shielding is provided for the electron gun set up. Electron gun tests can be tested upto 55 kV with pulse width of 15 microsecs and pulse repetition rates up to 200 Hz. The technical details of the subsystems are furnished and results of performance of the test stand have been reported in this paper. (author)

Wanmode, Yashwant D.; Mulchandani, J.; Acharya, M.; Bhisikar, A.; Singh, H.G.; Shrivastava, Purushottam, E-mail: yash@rrcat.gov.in [Pulsed High Power Microwave Section, Raja Ramanna Centre for Advanced Technology, Indore (India)

2011-07-01T23:59:59.000Z

174

Studies on High Voltage Lithium Rich MNC Composite Cathodes | Department of  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage »of Energy Strain Rate Characterization|Energy High Voltage Lithium

175

Correction coil cable  

DOE Patents [OSTI]

A wire cable assembly adapted for the winding of electrical coils is taught. A primary intended use is for use in particle tube assemblies for the Superconducting Super Collider. The correction coil cables have wires collected in wire array with a center rib sandwiched therebetween to form a core assembly. The core assembly is surrounded by an assembly housing having an inner spiral wrap and a counter wound outer spiral wrap. An alternate embodiment of the invention is rolled into a keystoned shape to improve radial alignment of the correction coil cable on a particle tube in a particle tube assembly. 7 figs.

Wang, S.T.

1994-11-01T23:59:59.000Z

176

Aerodynamics of a circular cylinder inclined to airflow and wind-induced vibrations of dry, inclined cables at high wind speeds .  

E-Print Network [OSTI]

??Cable-stayed bridges are an efficient and elegant solution to bridging long spans. Though a widely used structural system, several significant issues are still unresolved regarding… (more)

Zurell, Cory

2013-01-01T23:59:59.000Z

177

Stabilization of turbulent lifted jet flames assisted by pulsed high voltage discharge  

SciTech Connect (OSTI)

To reduce fuel consumption or the pollutant emissions of combustion (furnaces, aircraft engines, turbo-reactors, etc.), attempts are made to obtain lean mixture combustion regimes. These lead to poor stability of the flame. Thus, it is particularly interesting to find new systems providing more flexibility in aiding flame stabilization than the usual processes (bluff-body, stabilizer, quarl, swirl, etc.). The objective is to enlarge the stability domain of flames while offering flexibility at a low energy cost. Evidence is presented that the stabilization of a turbulent partially premixed flame of more than 10 kW can be enhanced by pulsed high-voltage discharges with power consumption less than 0.1% of the power of the flame. The originality of this work is to demonstrate that very effective stabilization of turbulent flames is obtained when high-voltage pulses with very short rise times are used (a decrease by 300% in terms of liftoff height for a given exit jet velocity can be reached) and to provide measurements of minimum liftoff height obtained with discharge over a large range of the stability domain of the lifted jet flame.

Criner, K.; Cessou, A.; Louiche, J.; Vervisch, P. [CORIA UMR 6614 CNRS-Universite et INSA de Rouen, University of Rouen, 76801 Saint Etienne du Rouvray (France)

2006-01-01T23:59:59.000Z

178

Potential impacts of vertical cable seismic: modeling, resolution and multiple attenuation  

E-Print Network [OSTI]

Vertical cable seismic methods are becoming more relevant as we require high quality and high resolution seismic data in both land and marine environments. Our goal in this thesis is to demonstrate the impacts of vertical cable surveying...

Wilson, Ryan Justin

2004-09-30T23:59:59.000Z

179

High voltage power supply systems for electron beam and plasma technologies. Its new element base  

SciTech Connect (OSTI)

Transforming technique and high voltage technique supplementing each other more and more unite in indivisible constructions of modern apparatuses and systems and applicated in modern technologies providing its high efficiency. Specially worked out, ecologically clean, inertial, inflammable perfluororganic liquid is used in elements and electronic apparatuses simultaneously as insulating and cooling media. This liquid is highly fluid, fills tiny cavities in construction elements and in the places of high concentration of losses, where maximum local overheating of active parts or apparatus constructions takes place, it transforms to boiling state with highly intensive taking off of heat energy from cooled surface point. For instance, being cooled by mentioned perfluororganic liquid, copper wire can conduct current to 50 A/mm{sup 2} density, but in ordinary conditions of transformers, reactors and busses, current density can reach only few Amperes. Possibility of considerable increasing of current density, that is reached by means of intensive cooling, provided by worked out liquid, and taking into account its incredibly high insulating features (liquid has electric strength to 50 KV/mm) allows to provide optimum heat regime of active parts of transformers. reactors, condenser, semiconductor devices, resistors, construction elements and electrotechnical apparatus in general. Particularly high effect of decreasing of weight and dimensions characteristics of elements and electrotechnical apparatus in general can be reached under working out of special constructions of each element and apparatus details, adapted to use of mentioned liquid as insulating and cooling media.

Dermengi, P.G.; Kureghan, A.S.; Pokrovsky, S.V.; Tchvanov, V.A.

1994-12-31T23:59:59.000Z

180

C-H surface diamond field effect transistors for high temperature (400?°C) and high voltage (500?V) operation  

SciTech Connect (OSTI)

By forming a highly stable Al{sub 2}O{sub 3} gate oxide on a C-H bonded channel of diamond, high-temperature, and high-voltage metal-oxide-semiconductor field-effect transistor (MOSFET) has been realized. From room temperature to 400?°C (673?K), the variation of maximum drain-current is within 30% at a given gate bias. The maximum breakdown voltage (V{sub B}) of the MOSFET without a field plate is 600?V at a gate-drain distance (L{sub GD}) of 7 ?m. We fabricated some MOSFETs for which V{sub B}/L{sub GD}?>?100?V/?m. These values are comparable to those of lateral SiC or GaN FETs. The Al{sub 2}O{sub 3} was deposited on the C-H surface by atomic layer deposition (ALD) at 450?°C using H{sub 2}O as an oxidant. The ALD at relatively high temperature results in stable p-type conduction and FET operation at 400?°C in vacuum. The drain current density and transconductance normalized by the gate width are almost constant from room temperature to 400?°C in vacuum and are about 10 times higher than those of boron-doped diamond FETs.

Kawarada, H., E-mail: kawarada@waseda.jp [Faculty of Science and Engineering, Waseda University, Shinjuku, Tokyo 169-8555 (Japan); Institute of Nano-Science and Nano-Engineering, Waseda University, Shinjuku, Tokyo 169-8555 (Japan); Kagami Memorial Laboratory for Material Science and Technology, Waseda University, Shinjuku, Tokyo 169-0051 (Japan); Tsuboi, H.; Naruo, T.; Yamada, T.; Xu, D.; Daicho, A.; Saito, T. [Faculty of Science and Engineering, Waseda University, Shinjuku, Tokyo 169-8555 (Japan); Hiraiwa, A. [Institute of Nano-Science and Nano-Engineering, Waseda University, Shinjuku, Tokyo 169-8555 (Japan)

2014-07-07T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Design and Fabrication of a High Voltage Distribution Box Michael Barnett  

E-Print Network [OSTI]

of paint. This ensured that the lock washers for the BNC plugs made solid electrical contacts with the box the shielding of the coaxial RG47 cable continuous, which helped to reduce noise injection into the lines. The BNC ports were manufactured by KINGS, part no. 1704-1. They used a lock washer and a threaded nut

Saskatchewan, University of

182

Monolithically interconnected GaAs solar cells: A new interconnection technology for high voltage solar cell output  

SciTech Connect (OSTI)

Photovoltaic linear concentrator arrays can benefit from high performance solar cell technologies being developed at AstroPower. Specifically, these are the integration of thin GaAs solar cell and epitaxial lateral overgrowth technologies with the application of monolithically interconnected solar cell (MISC) techniques. This MISC array has several advantages which make it ideal for space concentrator systems. These are high system voltage, reliable low cost monolithically formed interconnections, design flexibility, costs that are independent of array voltage, and low power loss from shorts, opens, and impact damage. This concentrator solar cell will incorporate the benefits of light trapping by growing the device active layers over a low-cost, simple, PECVD deposited silicon/silicon dioxide Bragg reflector. The high voltage-low current output results in minimal 12R losses while properly designing the device allows for minimal shading and resistance losses. It is possible to obtain open circuit voltages as high as 67 volts/cm of solar cell length with existing technology. The projected power density for the high performance device is 5 kW/m for an AMO efficiency of 26% at 1 5X. Concentrator solar cell arrays are necessary to meet the power requirements of specific mission platforms and can supply high voltage power for electric propulsion systems. It is anticipated that the high efficiency, GaAs monolithically interconnected linear concentrator solar cell array will enjoy widespread application for space based solar power needs. Additional applications include remote man-portable or ultra-light unmanned air vehicle (UAV) power supplies where high power per area, high radiation hardness and a high bus voltage or low bus current are important. The monolithic approach has a number of inherent advantages, including reduced cost per interconnect and increased reliability of array connections. There is also a high potential for a large number of consumer products.

Dinetta, L.C.; Hannon, M.H.

1995-10-01T23:59:59.000Z

183

1981). Their basic solution is to find a suitable backfilling material to minimize the contact resistance and to maintain high ground thermal conductivity around the cable even under very  

E-Print Network [OSTI]

resistance and to maintain high ground thermal conductivity around the cable even under very dry ground#12;1981). Their basic solution is to find a suitable backfilling material to minimize the contact thermal conductivity for clay backfilling, measured 1/2 inch and 6 inches (1.3 and 15 cm) away from

Oak Ridge National Laboratory

184

E-Print Network 3.0 - ac underground cable Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

i c e s VOICE & DATA Summary: ) The underground cable shall have an aluminium steel polyethylene (ASP) sheath and a core of solid... , transposition and presence of AC voltage. ...

185

High open circuit voltages of solar cells based on quantum dot and dye hybrid-sensitization  

SciTech Connect (OSTI)

A type of solar cell based on quantum dot (QD) and dye hybrid-sensitized mesoporous TiO{sub 2} film electrode was designed and reported. The electrode was consisted of a TiO{sub 2} nanoparticle (NP) thin film layer sensitized with CdS quantum dot (QD) and an amorphous TiO{sub 2} coated TiO{sub 2} NP thin film layer that sensitized with C106 dye. The amorphous TiO{sub 2} layer was obtained by TiCl{sub 4} post-treatment to improve the properties of solar cells. Research showed that the solar cells fabricated with as-prepared hybrid-sensitized electrode exhibited excellent photovoltaic performances and a fairly high open circuit voltage of 796?mV was achieved.

Zhao, Yujie; Zhao, Wanyu; Chen, Jingkuo; Li, Huayang; Fu, Wuyou, E-mail: hari@hpu.edu.cn, E-mail: fuwy56@163.com; Sun, Guang; Cao, Jianliang; Zhang, Zhanying [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China)] [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China); Bala, Hari, E-mail: hari@hpu.edu.cn, E-mail: fuwy56@163.com [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China) [School of Materials Science and Engineering and Cultivating Base for Key Laboratory of Environment-friendly Inorganic Materials in University of Henan Province, Henan Polytechnic University, Jiaozuo 454000 (China); College of Chemistry and Chemical Engineering, Inner Mongolia University for the Nationalities, Tongliao 028043 (China)

2014-01-06T23:59:59.000Z

186

Process for measuring degradation of sulfur hexafluoride in high voltage systems  

DOE Patents [OSTI]

This invention is a method of detecting the presence of toxic and corrosive by-products in high voltage systems produced by electrically induced degradation of SF/sub 6/ insulating gas in the presence of certain impurities. It is an improvement over previous methods because it is extremely sensitive, detecting by-products present in parts per billion concentrations, and because the device employed is of a simple design and takes advantage of the by-products natural affinity for fluoride ions. The method employs an ion-molecule reaction cell in which negative ions of the by-products are produced by fluorine attachment. These ions are admitted to a negative ion mass spectrometer and identified by their spectra. This spectrometry technique is an improvement over conventional techniques because the negative ion peaks are strong and not obscured by a major ion spectra of the SF/sub 6/ component as is the case in positive ion mass spectrometry.

Sauers, I.

1985-04-23T23:59:59.000Z

187

Low-Variation 1 MHz Clock Generator,High Sensitivity Linear Voltage-to-Frequency Converter,and High-PSR Bias Circuit for NTSC SYNC Separation.  

E-Print Network [OSTI]

??This thesis includes three topics. The first topic is a low-variation 1 MHz clock generator. The second one is a high sensitivity linear voltage-to-frequency converter.… (more)

Lee, Tzung-Je

2004-01-01T23:59:59.000Z

188

Integration of offshore wind farms through High Voltage Direct Current networks.  

E-Print Network [OSTI]

??The integration of offshore wind farms through Multi Terminal DC (MTDC) networks into the GB network was investigated. The ability of Voltage Source Converter (VSC)… (more)

Livermore, Luke

2013-01-01T23:59:59.000Z

189

FINE-GRAINED NANOCRYSTALLINE SILICON P-LAYER FOR HIGH OPEN CIRCUIT VOLTAGE A-SI:H SOLAR CELLS  

E-Print Network [OSTI]

FINE-GRAINED NANOCRYSTALLINE SILICON P-LAYER FOR HIGH OPEN CIRCUIT VOLTAGE A-SI:H SOLAR CELLS of Michigan, Ann Arbor, MI 48109, USA ABSTRACT Hydrogenated amorphous silicon (a-Si:H) single- junction solar). It is found that the p-layer that leads to high Voc a-Si:H solar cells is a mixed-phase material that contains

Deng, Xunming

190

Mechanisms of deflagration-to-detonation transition under initiation by high-voltage nanosecond discharges  

SciTech Connect (OSTI)

An experimental study of detonation initiation in a stoichiometric propane-oxygen mixture by a high-voltage nanosecond gas discharge was performed in a detonation tube with a single-cell discharge chamber. The discharge study performed in this geometry showed that three modes of discharge development were realized under the experimental conditions: a spark mode with high-temperature channel formation, a streamer mode with nonuniform gas excitation, and a transient mode. Under spark and transient initiation, simultaneous ignition inside the discharge channel occurred, forming a shock wave and leading to a conventional deflagration-to-detonation transition (DDT) via an adiabatic explosion. The DDT length and time at 1 bar of initial pressure in the square smooth tube with a 20-mm transverse size amounted to 50 mm and 50{mu}s, respectively. The streamer mode of discharge development at an initial pressure of 1 bar resulted in nonuniform mixture excitation and a successful DDT via a gradient mechanism, which was confirmed by high-speed time resolved ICCD imaging. The gradient mechanism implied a longer DDT time of 150{mu}s, a DDT run-up distance of 50 mm, and an initiation energy of 1 J, which is two orders of magnitude less than the direct initiation energy for a planar detonation under these conditions. (author)

Rakitin, Aleksandr E.; Starikovskii, Andrei Yu. [Physics of Nonequilibrium Systems Lab, Moscow Institute of Physics and Technology, 9 Institutski Lane, Dolgoprudny 141700 (Russian Federation)

2008-10-15T23:59:59.000Z

191

Wide-span cable structures  

E-Print Network [OSTI]

In recent years, the application of cable structures in buildings has gained huge popularities. Although cable technology has been established since the 1950s, there is suddenly a surge in the number of its building ...

Santoso, Katherina, 1980-

2004-01-01T23:59:59.000Z

192

Atmospheric pressure plasma jet with high-voltage power supply based on piezoelectric transformer  

SciTech Connect (OSTI)

The dielectric barrier discharge plasma jet, an example of the nonthermal atmospheric pressure plasma jet (APPJ), generates low-temperature plasmas that are suitable for the atomization of volatile species and can also be served as an ionization source for ambient mass and ion mobility spectrometry. A new design of APPJ for mass spectrometry has been built in our group. In these plasma sources magnetic transformers (MTs) and inductors are typically used in power supplies but they present several drawbacks that are even more evident when dealing with high-voltage normally used in APPJs. To overcome these disadvantages, high frequency generators with the absence of MT are proposed in the literature. However, in the case of miniaturized APPJs these conventional power converters, built of ferromagnetic cores and inductors or by means of LC resonant tank circuits, are not so useful as piezoelectric transformer (PT) based power converters due to bulky components and small efficiency. We made and examined a novel atmospheric pressure plasma jet with PT supplier served as ionization source for ambient mass spectrometry, and especially mobile spectrometry where miniaturization, integration of components, and clean plasma are required. The objective of this paper is to describe the concept, design, and implementation of this miniaturized piezoelectric transformer-based atmospheric pressure plasma jet.

Babij, Micha?; Kowalski, Zbigniew W., E-mail: zbigniew.w.kowalski@pwr.wroc.pl; Nitsch, Karol; Gotszalk, Teodor [Wroc?aw University of Technology, Wybrze?e Wyspia?skiego 27, 50-370 Wroc?aw (Poland)] [Wroc?aw University of Technology, Wybrze?e Wyspia?skiego 27, 50-370 Wroc?aw (Poland); Silberring, Jerzy [AGH University of Science and Technology, Al. A. Mickiewicza 30, 30-059 Kraków (Poland)] [AGH University of Science and Technology, Al. A. Mickiewicza 30, 30-059 Kraków (Poland)

2014-05-15T23:59:59.000Z

193

A three-level buck converter to regulate a high-voltage DC-to-AC inverter  

E-Print Network [OSTI]

A three-level buck converter is designed and analyzed, and shown to be suitable as a high-voltage down converter as a pre-regulation stage for a 600 watt DC-to-AC power inverter. Topology selection for the inverter is ...

Schrock, Kenneth C

2008-01-01T23:59:59.000Z

194

Disposable telemetry cable deployment system  

DOE Patents [OSTI]

A disposable telemetry cable deployment system for facilitating information retrieval while drilling a well includes a cable spool adapted for insertion into a drill string and an unarmored fiber optic cable spooled onto the spool cable and having a downhole end and a stinger end. Connected to the cable spool is a rigid stinger which extends through a kelly of the drilling apparatus. A data transmission device for transmitting data to a data acquisition system is disposed either within or on the upper end of the rigid stinger.

Holcomb, David Joseph (Sandia Park, NM)

2000-01-01T23:59:59.000Z

195

High-Efficiency Multiple-Output DC-DC Conversion for Low-Voltage Systems  

E-Print Network [OSTI]

This versatile power converter controller provides dual outputs at a fixed switching frequency and can regulate either output voltage or target system delay (using an external -- filter). In the voltage regulation mode, the output voltage is monitored with an analog--digital (A/D) converter, and the feedback compensation network is implemented digitally. The generation of the pulsewidth modulation (PWM) signal is done with a hybrid delay line/counter approach, which saves power and area relative to previous implementations. Power devices are included on chip to create the two independently regulated output PWM signals. The key features of this design are its low-power dissipation, reconfigurability, use of either delay or voltage feedback, and multiple outputs.

Abram P. Dancy; Rajeevan Amirtharajah; Anantha P. Chandrakasan

2000-01-01T23:59:59.000Z

196

Redesign of the H-Bridge Switch Plate of the SNS High Voltage Converter Modulator  

SciTech Connect (OSTI)

The 1-MW High Voltage Converter Modulators [1] have operated in excess of 250,000 hours at the Spallation Neutron Source. Increased demands on the accelerator performance require increased modulator reliability. An effort is underway at SLAC National Accelerator Laboratory to redesign the modulator H-bridge switch plate with the goals of increasing reliability and performance [2]. The major difference between the SLAC design and the existing design is the use of press-pack IGBTs. Compared to other packaging options, these IGBTs have been shown to have increased performance in pulsed-power applications, have increased cooling capability, and do not fragment and disassemble during a fault event. An overview of the SLAC switch plate redesign is presented. Design steps including electrical modeling of the modulator and H-bridge, development of an integrated IGBT clamping mechanism, and fault tests are discussed. Experimental results will be presented comparing electrical performance of the SLAC switch plate to the existing switchplate under normal and fault conditions.

Kemp, M.A.; Burkhart, C.; Nguyen, M.N.; /SLAC; Anderson, D.E.; /Oak Ridge

2009-05-07T23:59:59.000Z

197

Complete Fiber/Copper Cable Solution for Long-Term Temperature...  

Broader source: Energy.gov (indexed) [DOE]

tool. EGS Challenges for Cable Performance: - Very high temperatures - Highly corrosive environment - High pressure - Self supporting deployment 3 | US DOE Geothermal Office...

198

Laboratory testing of repellents to prevent nutria damage to seismic cable  

E-Print Network [OSTI]

. The adhesive used was Rhoplex AC-33, manufactured by the Rohm and Haas Company. This excellent adhesive is highly flexible, and has good weathering characteristics. The type of cable used to test the chemical repellents was two-conductor geophone strings... cable, chemically treated test cables, and internally armored cable. Bio-Met 12 and its derivation were tested in the form made available by the manufacturer. R-55 and Gustafson 425 were tested at the 10% solution of active ingredients in association...

Gunn, Scott Jeter

1980-01-01T23:59:59.000Z

199

Method to improve superconductor cable  

DOE Patents [OSTI]

A method is disclosed of making a stranded superconductor cable having improved flexing and bending characteristics. In such method, a plurality of superconductor strands are helically wound around a cylindrical portion of a mandrel which tapers along a transitional portion to a flat end portion. The helically wound strands form a multistrand hollow cable which is partially flattened by pressure rollers as the cable travels along the transitional portion. The partially flattened cable is impacted with repeated hammer blows as the hollow cable travels along the flat end portion. The hammer blows flatten both the internal and the external surfaces of the strands. The cable is fully flattened and compacted by two sets of pressure rollers which engage the flat sides and the edges of the cable after it has traveled away from the flat end portion of the mandrel. The flattened internal surfaces slide easily over one another when the cable is flexed or bent so that there is very little possibility that the cable will be damaged by the necessary flexing and bending required to wind the cable into magnet coils.

Borden, A.R.

1984-03-08T23:59:59.000Z

200

Graphene-oxide-coated LiNi0.5Mn1.5O4 as high voltage cathode for lithium ion batteries with high energy  

E-Print Network [OSTI]

Graphene-oxide-coated LiNi0.5Mn1.5O4 as high voltage cathode for lithium ion batteries with high Since Sony rst commercialized lithium ion batteries in the early 1990s, the market for lithium ion of the great success of lithium ion battery technology developed for portable electronic devices, higher

Zhou, Chongwu

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

High voltage capability electrical coils insulated with materials containing SF.sub.6 gas  

DOE Patents [OSTI]

A coil is made having a plurality of layers of adjacent metal conductor windings subject to voltage stress, where the windings have insulation therebetween containing a small number of minute disposed throughout its cross-section, where the voids are voids filled with SF.sub.6 gas to substitute for air or other gaseous materials in from about 60% to about 95% of the cross-sectional void volume in the insulation, thus incorporating an amount of SF.sub.6 gas in the cross-section of the insulation effective to substantially increase corona inception voltages.

Lanoue, Thomas J. (Muncie, IN); Zeise, Clarence L. (Penn Township, Allegheny County, PA); Wagenaar, Loren (Muncie, IN); Westervelt, Dean C. (Acme, PA)

1988-01-01T23:59:59.000Z

202

Thermal management of long-length HTS cable systems  

SciTech Connect (OSTI)

Projections of electric power production suggest a major shift to renewables, such as wind and solar, which will be in remote locations where massive quantities of power are available. One solution for transmitting this power over long distances to load centers is direct current (dc), high temperature superconducting (HTS) cables. Electric transmission via dc cables promises to be effective because of the low-loss, highcurrent- carrying capability of HTS wire at cryogenic temperatures. However, the thermal management system for the cable must be carefully designed to achieve reliable and energyefficient operation. Here we extend the analysis of a superconducting dc cable concept proposed by the Electric Power Research Institute (EPRI), which has one stream of liquid nitrogen flowing in a cryogenic enclosure that includes the power cable, and a separate return tube for the nitrogen. Refrigeration stations positioned every 10 to 20 km cool both nitrogen streams. Both go and return lines are contained in a single vacuum/cryogenic envelope. Other coolants, including gaseous helium and gaseous hydrogen, could provide potential advantages, though they bring some technical challenges to the operation of long-length HTS dc cable systems. A discussion of the heat produced in superconducting cables and a system to remove the heat are discussed. Also, an analysis of the use of various cryogenic fluids in long-distance HTS power cables is presented.

Demko, Jonathan A [ORNL; Hassenzahl, William V [ORNL

2011-01-01T23:59:59.000Z

203

High-voltage field effect transistors with wide-bandgap ?-Ga{sub 2}O{sub 3} nanomembranes  

SciTech Connect (OSTI)

Nanoscale semiconductor materials have been extensively investigated as the channel materials of transistors for energy-efficient low-power logic switches to enable scaling to smaller dimensions. On the opposite end of transistor applications is power electronics for which transistors capable of switching very high voltages are necessary. Miniaturization of energy-efficient power switches can enable the integration with various electronic systems and lead to substantial boosts in energy efficiency. Nanotechnology is yet to have an impact in this arena. In this work, it is demonstrated that nanomembranes of the wide-bandgap semiconductor gallium oxide can be used as channels of transistors capable of switching high voltages, and at the same time can be integrated on any platform. The findings mark a step towards using lessons learnt in nanomaterials and nanotechnology to address a challenge that yet remains untouched by the field.

Hwang, Wan Sik, E-mail: whwang@kau.ac.kr, E-mail: djena@nd.edu [Department of Materials Engineering, Korea Aerospace University, Gyeonggi, 412791 (Korea, Republic of); Verma, Amit; Protasenko, Vladimir; Rouvimov, Sergei; Xing, Huili; Seabaugh, Alan; Jena, Debdeep, E-mail: whwang@kau.ac.kr, E-mail: djena@nd.edu [Department of Electrical Engineering, University of Notre Dame, Notre Dame, Indiana 46556 (United States); Peelaers, Hartwin; Van de Walle, Chris [Materials Department, University of California Santa Barbara, California 93106 (United States); Haensch, Wilfried [IBM T. J. Watson Research Center, Yorktown Heights, New York 10598 (United States); Galazka, Zbigniew; Albrecht, Martin [Leibniz Institute for Crystal Growth, Max-Born Str., D-12489 Berlin (Germany); Fornari, Roberto [Leibniz Institute for Crystal Growth, Max-Born Str., D-12489 Berlin (Germany); Department of Physics and Earth Science, University of Parma, Parma, 43124 Italy (Italy)

2014-05-19T23:59:59.000Z

204

Plasma Immersion Ion Implantation with a 4kV/10kHz Compact High Voltage Pulser  

SciTech Connect (OSTI)

Development of a 4 kV/10 kHz Compact High Voltage Pulser and its application to nitrogen plasma immersion ion implantation (PIII) of different materials as Si, Al alloys, SS304 stainless steel and Ti alloys are discussed. Low voltage (1-5 kV) pulses at high frequencies (up to 20 kHz for 2 kV) were obtained with maximum power delivered at 5 kV, 7 kHz. These conditions were not sufficient to reach temperatures above 200 deg. C in the samples because of short duration of the pulses. However, very shallow implantations of nitrogen in Si, Al5052, SS304 were observed by Auger electron spectroscopy and improved corrosion resistance was obtained for Al5052 when it was treated by nitrogen PIII at 2.5 kV, 5{mu}s and 5 kHz pulses.

Ueda, M.; Oliveira, R. M.; Rossi, J. O. [Associated Laboratory of Plasma, National Institute for Space Research, Av. dos Astronautas 1758, Sao Jose dos Campos, Sao Paulo (Brazil); Reuther, H. [Institute of Ion Beam Physics and Materials Research, Rossendorf, Dresden (Germany); Silva, G. [Associated Laboratory of Plasma, National Institute for Space Research, Av. dos Astronautas 1758, Sao Jose dos Campos, Sao Paulo (Brazil); Department of Aeronautics and Mechanics, Technological Institute of Aeronautics, Sao Jose dos Campos, Sao Paulo (Brazil)

2006-11-13T23:59:59.000Z

205

Microminiature coaxial cable and methods manufacture  

DOE Patents [OSTI]

A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 [mu]m thick and from 150 to 200 [mu]m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microballoons to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion. 2 figs.

Bongianni, W.L.

1986-04-08T23:59:59.000Z

206

Microminiature coaxial cable and methods of manufacture  

DOE Patents [OSTI]

A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 ..mu..m thick and from 150 to 200 ..mu..m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dieleectric. Alternately the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microballoons to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion.

Bongianni, W.L.

1983-12-29T23:59:59.000Z

207

Microminiature coaxial cable and method of manufacture  

DOE Patents [OSTI]

A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 .mu.m thick and from 150 to 200 .mu.m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately, the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microspheres to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion.

Bongianni, Wayne L. (Los Alamos, NM)

1989-01-01T23:59:59.000Z

208

Microminiature coaxial cable and method of manufacture  

DOE Patents [OSTI]

A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 [mu]m thick and from 150 to 200 [mu]m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately, the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microspheres to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion. 2 figs.

Bongianni, W.L.

1989-03-28T23:59:59.000Z

209

Microminiature coaxial cable and methods manufacture  

DOE Patents [OSTI]

A coaxial cable is provided having a ribbon inner conductor surrounded by a dielectric and a circumferential conductor. The coaxial cable may be microminiature comprising a very thin ribbon strip conductor from between 5 to 15 .mu.m thick and from 150 to 200 .mu.m wide, having a surrounding foamed dielectric or parylene applied thereon by a vapor plasma process and an outer conductor of an adhering high conductivity metal vacuum deposited on the dielectric. Alternately the foam dielectric embodiment may have a contiguous parylene coating applied adjacent the inner conductor or the outer conductor or both. Also, the cable may be fabricated by forming a thin ribbon of strip conductive material into an inner conductor, applying thereabout a dielectric by spraying on a solution of polystyrene and polyethylene and then vacuum depositing and adhering high conductivity metal about the dielectric. The cable strength may be increased by adding glass microfilament fibers or glass microballoons to the solution of polystyrene and polyethylene. Further, the outer conductive layer may be applied by electroless deposition in an aqueous solution rather than by vacuum deposition. A thin coating of parylene is preferably applied to the outer conductor to prevent its oxidation and inhibit mechanical abrasion.

Bongianni, Wayne L. (408 Colleen Ct., Los Alamos, NM 87544)

1986-01-01T23:59:59.000Z

210

Alternative p-doped hole transport material for low operating voltage and high efficiency organic light-emitting diodes  

SciTech Connect (OSTI)

We investigate the properties of N,N?-[(Diphenyl-N,N?-bis)9,9,-dimethyl-fluoren-2-yl]-benzidine (BF-DPB) as hole transport material (HTL) in organic light-emitting diodes (OLEDs) and compare BF-DPB to the commonly used HTLs N,N,N?,N?-tetrakis(4-methoxyphenyl)-benzidine (MeO-TPD), 2,2?,7,7?-tetrakis(N,N?-di-p-methylphenylamino)-9,9?-spirobifluorene (Spiro-TTB), and N,N?-di(naphtalene-1-yl)-N,N?-diphenylbenzidine (NPB). The influence of 2,2?-(perfluoronaphthalene-2,6-diylidene)dimalononitrile (F6-TCNNQ p-dopant) concentration in BF-DPB on the operation voltage and efficiency of red and green phosphorescent OLEDs is studied; best results are achieved at 4?wt. % doping. Without any light extraction structure, BF-DPB based red (green) OLEDs achieve a luminous efficacy of 35?.1?lm/W (74?.0?lm/W) at 1000?cd/m{sup 2} and reach a very high brightness of 10?000 cd/m{sup 2} at a very low voltage of 3.2 V (3.1 V). We attribute this exceptionally low driving voltage to the high ionization potential of BF-DPB which enables more efficient hole injection from BF-DPB to the adjacent electron blocking layer. The high efficiency and low driving voltage lead to a significantly lower luminous efficacy roll-off compared to the other compounds and render BF-DPB an excellent HTL material for highly efficient OLEDs.

Murawski, Caroline, E-mail: caroline.murawski@iapp.de; Fuchs, Cornelius; Hofmann, Simone; Leo, Karl [Institut für Angewandte Photophysik, Technische Universität Dresden, George-Bähr-Str. 1, 01062 Dresden (Germany); Gather, Malte C. [Institut für Angewandte Photophysik, Technische Universität Dresden, George-Bähr-Str. 1, 01062 Dresden (Germany); SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, KY16 9SS Scotland (United Kingdom)

2014-09-15T23:59:59.000Z

211

Holbrook Substation Superconductor Cable System, Long Island, New York Final Report  

SciTech Connect (OSTI)

The LIPA Superconductor project broke ground on July 4, 2006, was first energized on April 22, 2008 (Earth Day) and was commissioned on June 25, 2008. Since commissioning, up until early March, 2009, there were numerous refrigeration events that impacted steady state operations. This led to the review of the alarms that were being generated and a rewrite of the program logic in order to decrease the hypersensitivity surrounding these alarms. The high temperature superconductor (HTS) cable was energized on March 5, 2009 and ran uninterrupted until a human error during a refrigeration system switchover knocked the cable out of the grid in early February 2010. The HTS cable was in the grid uninterrupted from March 5, 2009 to February 4, 2010. Although there have been refrigeration events (propagated mainly by voltage sags/surges) during this period, the system was able to automatically switch over from the primary to the backup refrigeration system without issue as required during this period. On February 4, 2010, when switching from the backup over to the primary refrigeration system, two rather than one liquid nitrogen pumps were started inadvertently by a human error (communication) causing an overpressure in the cable cooling line. This in turn activated the pressure relief valve located in the grounding substation. The cable was automatically taken out of the grid without any damage to the components or system as a result of signals sent from the AMSC control cabinet to the LIPA substation. The cable was switched back into the grid again on March 16, 2010 without incident and has been operational since that time. Since switching from the backup to the primary is not an automatic process, a recent improvement was added to the refrigeration operating system to allow remote commands to return the system from backup to primary cooling. This improvement makes the switching procedure quicker since travel to the site to perform this operation is no longer necessary and safer since it is now a programmed procedure versus the former written procedure that was still subject to human variation in the process.

Maguire, James; McNamara, Joseph

2010-06-25T23:59:59.000Z

212

Development of 500 kV DC PPLP-insulated oil-filled submarine cable  

SciTech Connect (OSTI)

This paper outlines the development of a 500 kV DC oil-filled submarine cable capable of transmitting 2,800 MW with {+-} 500 kV 2800A bipole system. Polypropylene Laminated Paper (PPL) was employed as the insulation material, which is the worlds first application to DC cables. The conductor size is 3,000 mm{sup 2}, which is the largest size for submarine cables ever put into practical use. Through various fundamental and prototype tests, the cable proved to have excellent electrical characteristics for DC voltage as well as transient overvoltage. The cable and accessories are currently undergoing a long-term accelerated aging test as the final confirmation of their reliability and stability.

Fujimori, A. [Kansai Electric Power Co., Inc., Osaka (Japan)] [Kansai Electric Power Co., Inc., Osaka (Japan); Tanaka, T. [Electric Power Development Co., Ltd., Tokyo (Japan)] [Electric Power Development Co., Ltd., Tokyo (Japan); Takashima, H. [Shikoku Electric Power Co., Inc., Kagawa (Japan)] [Shikoku Electric Power Co., Inc., Kagawa (Japan); Imajo, T. [Central Research Inst. of Electric Power Industry, Tokyo (Japan)] [Central Research Inst. of Electric Power Industry, Tokyo (Japan); Hata, R. [Sumitomo Electric Industries, Ltd., Osaka (Japan)] [Sumitomo Electric Industries, Ltd., Osaka (Japan); Tanabe, T. [Furukawa Electric Co., Ltd., Tokyo (Japan)] [Furukawa Electric Co., Ltd., Tokyo (Japan); Yoshida, S. [Fujikura, Ltd., Tokyo (Japan)] [Fujikura, Ltd., Tokyo (Japan); Kakihana, T. [Hitachi Cable, Ltd., Tokyo (Japan)] [Hitachi Cable, Ltd., Tokyo (Japan)

1996-01-01T23:59:59.000Z

213

Photonic-powered cable assembly  

DOE Patents [OSTI]

A photonic-cable assembly includes a power source cable connector ("PSCC") coupled to a power receive cable connector ("PRCC") via a fiber cable. The PSCC electrically connects to a first electronic device and houses a photonic power source and an optical data transmitter. The fiber cable includes an optical transmit data path coupled to the optical data transmitter, an optical power path coupled to the photonic power source, and an optical feedback path coupled to provide feedback control to the photonic power source. The PRCC electrically connects to a second electronic device and houses an optical data receiver coupled to the optical transmit data path, a feedback controller coupled to the optical feedback path to control the photonic power source, and a photonic power converter coupled to the optical power path to convert photonic energy received over the optical power path to electrical energy to power components of the PRCC.

Sanderson, Stephen N.; Appel, Titus James; Wrye, IV, Walter C.

2013-01-22T23:59:59.000Z

214

Photonic-powered cable assembly  

DOE Patents [OSTI]

A photonic-cable assembly includes a power source cable connector ("PSCC") coupled to a power receive cable connector ("PRCC") via a fiber cable. The PSCC electrically connects to a first electronic device and houses a photonic power source and an optical data transmitter. The fiber cable includes an optical transmit data path coupled to the optical data transmitter, an optical power path coupled to the photonic power source, and an optical feedback path coupled to provide feedback control to the photonic power source. The PRCC electrically connects to a second electronic device and houses an optical data receiver coupled to the optical transmit data path, a feedback controller coupled to the optical feedback path to control the photonic power source, and a photonic power converter coupled to the optical power path to convert photonic energy received over the optical power path to electrical energy to power components of the PRCC.

Sanderson, Stephen N; Appel, Titus James; Wrye, IV, Walter C

2014-06-24T23:59:59.000Z

215

Correlation of electrical reactor cable failure with materials degradation  

SciTech Connect (OSTI)

Complete circuit failure (shortout) of electrical cables typically used in nuclear power plant containments is investigated. Failure modes are correlated with the mechanical deterioration of the elastomeric cable materials. It is found that for normal reactor operation, electrical cables are reliable and safe over very long periods. During high temperature excursions, however, cables pulled across corners under high stress may short out due to conductor creep. Severe cracking will occur in short times during high temperatures (>150/sup 0/C) and in times of the order of years at elevated temperatures (100/sup 0/C to 140/sup 0/C). A theoretical treatment of stress distribution responsible for creep and for cracking by J.E. Reaugh of Science Applications, Inc. is contained in the Appendix. 29 refs., 32 figs.

Stuetzer, O.M.

1986-03-01T23:59:59.000Z

216

Optical voltage reference  

DOE Patents [OSTI]

An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

Rankin, R.; Kotter, D.

1994-04-26T23:59:59.000Z

217

Experimental investigation of dielectric barrier discharge plasma actuators driven by repetitive high-voltage nanosecond pulses with dc or low frequency sinusoidal bias  

SciTech Connect (OSTI)

Experimental studies were conducted of a flow induced in an initially quiescent room air by a single asymmetric dielectric barrier discharge driven by voltage waveforms consisting of repetitive nanosecond high-voltage pulses superimposed on dc or alternating sinusoidal or square-wave bias voltage. To characterize the pulses and to optimize their matching to the plasma, a numerical code for short pulse calculations with an arbitrary impedance load was developed. A new approach for nonintrusive diagnostics of plasma actuator induced flows in quiescent gas was proposed, consisting of three elements coupled together: the schlieren technique, burst mode of plasma actuator operation, and two-dimensional numerical fluid modeling. The force and heating rate calculated by a plasma model was used as an input to two-dimensional viscous flow solver to predict the time-dependent dielectric barrier discharge induced flow field. This approach allowed us to restore the entire two-dimensional unsteady plasma induced flow pattern as well as characteristics of the plasma induced force. Both the experiments and computations showed the same vortex flow structures induced by the actuator. Parametric studies of the vortices at different bias voltages, pulse polarities, peak pulse voltages, and pulse repetition rates were conducted experimentally. The significance of charge buildup on the dielectric surface was demonstrated. The charge buildup decreases the effective electric field in the plasma and reduces the plasma actuator performance. The accumulated surface charge can be removed by switching the bias polarity, which leads to a newly proposed voltage waveform consisting of high-voltage nanosecond repetitive pulses superimposed on a high-voltage low frequency sinusoidal voltage. Advantages of the new voltage waveform were demonstrated experimentally.

Opaits, Dmitry F.; Likhanskii, Alexandre V.; Neretti, Gabriele; Zaidi, Sohail; Shneider, Mikhail N.; Miles, Richard B. [Mechanical and Aerospace Engineering, Princeton University, Princeton, New Jersey 08544 (United States); Macheret, Sergey O. [Lockheed Martin Aeronautics Company, Palmdale, California 93599 (United States)

2008-08-15T23:59:59.000Z

218

Analysis of system wide distortion in an integrated power system utilizing a high voltage DC bus and silicon carbide power devices  

E-Print Network [OSTI]

This research investigates the distortion on the electrical distribution system for a high voltage DC Integrated Power System (IPS). The analysis was concentrated on the power supplied to a propulsion motor driven by an ...

Fallier, William F. (William Frederick)

2007-01-01T23:59:59.000Z

219

Low Beam Voltage, 10 MW, L-Band Cluster Klystron  

SciTech Connect (OSTI)

Conceptual design of a multi-beam klystron (MBK) for possible ILC and Project X applications is presented. The chief distinction between this MBK design and existing 10-MW MBK's is the low operating voltage of 60 kV. There are at least four compelling reasons that justify development at this time of a low-voltage MBK, namely (1) no pulse transformer; (2) no oil tank for high-voltage components and for the tube socket; (3) no high-voltage cables; and (4) modulator would be a compact 60-kV IGBT switching circuit. The proposed klystron consists of four clusters containing six beams each. The tube has common input and output cavities for all 24 beams, and individual gain cavities for each cluster. A closely related optional configuration, also for a 10 MW tube, would involve four totally independent cavity clusters with four independent input cavities and four 2.5 MW output ports, all within a common magnetic circuit. This option has appeal because the output waveguides would not require a controlled atmosphere, and because it would be easier to achieve phase and amplitude stability as required in individual SC accelerator cavities.

Teryaev, V.; /Novosibirsk, IYF; Yakovlev, V.P.; /Fermilab; Kazakov, S.; /KEK, Tsukuba; Hirshfield, J.L.; /Yale U. /Omega-P, New Haven

2009-05-01T23:59:59.000Z

220

Complete Fiber/Copper Cable Solution for Long-Term Temperature...  

Broader source: Energy.gov (indexed) [DOE]

Cable Solution for Long-Term Temperature and Pressure Measurement in Supercritical Reservoirs and EGS Wells High Temperature ESP Monitoring Geothermal Ultrasonic Fracture Imager...

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Recommended practice for fire protection for electric generating plants and high voltage direct current converter stations. 2005 ed.  

SciTech Connect (OSTI)

The standard outlines fire safety recommendations for gas, oil, coal, and alternative fuel electric generating plants including high voltage direct current converter stations and combustion turbine units greater than 7500 hp used for electric generation. Provisions apply to both new and existing plants. The document provides fire prevention and fire protection recommendations for the: safety of construction and operating personnel; physical integrity of plant components; and continuity of plant operations. The 2005 edition includes revisions and new art that clarify existing provisions. 5 annexes.

NONE

2005-07-01T23:59:59.000Z

222

A high-stability scanning tunneling microscope achieved by an isolated tiny scanner with low voltage imaging capability  

SciTech Connect (OSTI)

We present a novel homebuilt scanning tunneling microscope (STM) with high quality atomic resolution. It is equipped with a small but powerful GeckoDrive piezoelectric motor which drives a miniature and detachable scanning part to implement coarse approach. The scanning part is a tiny piezoelectric tube scanner (industry type: PZT-8, whose d{sub 31} coefficient is one of the lowest) housed in a slightly bigger polished sapphire tube, which is riding on and spring clamped against the knife edges of a tungsten slot. The STM so constructed shows low back-lashing and drifting and high repeatability and immunity to external vibrations. These are confirmed by its low imaging voltages, low distortions in the spiral scanned images, and high atomic resolution quality even when the STM is placed on the ground of the fifth floor without any external or internal vibration isolation devices.

Wang, Qi; Wang, Junting; Lu, Qingyou, E-mail: qxl@ustc.edu.cn [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China) [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China); Hefei National Laboratory for Physical Sciences at Microscale, University of Science and Technology of China, Hefei, Anhui 230026 (China); Hou, Yubin [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China)] [High Magnetic Field Laboratory, Chinese Academy of Sciences and University of Science and Technology of China, Hefei, Anhui 230026 (China)

2013-11-15T23:59:59.000Z

223

Improving the performance of stainless-steel DC high voltage photoelectron gun cathode electrodes via gas conditioning with helium or krypton  

SciTech Connect (OSTI)

Gas conditioning was shown to eliminate field emission from cathode electrodes used inside DC high voltage photoelectron guns, thus providing a reliable means to operate photoguns at higher voltages and field strengths. Measurements and simulation results indicate that gas conditioning eliminates field emission from cathode electrodes via two mechanisms: sputtering and implantation, with the benefits of implantation reversed by heating the electrode. We have studied five stainless steel electrodes (304L and 316LN) that were polished to approximately 20 nm surface roughness using diamond grit, and evaluated inside a high voltage apparatus to determine the onset of field emission as a function of voltage and field strength. The field emission characteristics of each electrode varied significantly upon the initial application of voltage but improved to nearly the same level after gas conditioning using either helium or krypton, exhibiting less than 10 pA field emission at ?225 kV bias voltage with a 50 mm cathode/anode gap, corresponding to a field strength of ~13 MV/m. Field emission could be reduced with either gas, but there were conditions related to gas choice, voltage and field strength that were more favorable than others.

Bastaninejad, Mahzad [ODU; Elmustafa, Abdelmageed [ODU; Forman, Eric I. [JLAB; Clark, James [JLAB; Covert, Steven R. [JLAB; Grames, Joseph M. [JLAB; Hansknecht, John C. [JLAB; Hernandez-Garcia, Carlos [JLAB; Poelker, Bernard [JLAB; Suleiman, Riad S. [JLAB

2014-10-01T23:59:59.000Z

224

HVDC submarine power cables systems state of the art and future developments  

SciTech Connect (OSTI)

The paper begins with an introduction on the reasons that lead to the use of HVDC submarine cable links. The main aspects for the choice of direct current are presented as well as the advantages deriving from the utilization of submarine cables. The second part is dedicated to a discussion on the various type of insulation that could be used in power cables and their possible application to HVDC submarine cables. In the following there is a description of the main characteristics and technical details of some particular project that at present time (1995) are in progress. Two projects are briefly presented: Spain-Morocco, a 26 km long interconnection for the transmission, in a first phase, of 700 MW from Spain to Morocco at 400 kV a.c. by means of three cables, plus one spare, of the fluid filled type. The cables are designed for a future change to d.c. 450 kV, allowing a transmission of 500 MW each (i.e., 2 GW total). One of the peculiarities of the link is the maximum water depth of 615 m (world record for submarine power cables at the time of installation). Italy-Greece, a 1km long interconnection for the transmission of 500 MW (bi-directional) by means of one paper insulated mass impregnated cable having 1,250 sq mm conductor size and insulated for a rated voltage of 400 kV. This link (the installation of which will be posterior to the Spain-Morocco) will attain the world record for the maximum water depth for submarine power cables: 1,000 m. The last part deals with the future developments expected in this field, in terms of conductor size and voltage, that means an increase in transmissible capacity.

Valenza, D.; Cipollini, G. [Pirelli Cavi S.p.A., Milano (Italy)

1995-12-31T23:59:59.000Z

225

Nanosecond pulsed electric fields (nsPEFs) low cost generator design using power MOSFET and Cockcroft-Walton multiplier circuit as high voltage DC source  

SciTech Connect (OSTI)

Purpose: Non-ionizing radiation therapy for cancer using pulsed electric field with high intensity field has become an interesting field new research topic. A new method using nanosecond pulsed electric fields (nsPEFs) offers a novel means to treat cancer. Not like the conventional electroporation, nsPEFs able to create nanopores in all membranes of the cell, including membrane in cell organelles, like mitochondria and nucleus. NsPEFs will promote cell death in several cell types, including cancer cell by apoptosis mechanism. NsPEFs will use pulse with intensity of electric field higher than conventional electroporation, between 20–100 kV/cm and with shorter duration of pulse than conventional electroporation. NsPEFs requires a generator to produce high voltage pulse and to achieve high intensity electric field with proper pulse width. However, manufacturing cost for creating generator that generates a high voltage with short duration for nsPEFs purposes is highly expensive. Hence, the aim of this research is to obtain the low cost generator design that is able to produce a high voltage pulse with nanosecond width and will be used for nsPEFs purposes. Method: Cockcroft-Walton multiplier circuit will boost the input of 220 volt AC into high voltage DC around 1500 volt and it will be combined by a series of power MOSFET as a fast switch to obtain a high voltage with nanosecond pulse width. The motivation using Cockcroft-Walton multiplier is to acquire a low-cost high voltage DC generator; it will use capacitors and diodes arranged like a step. Power MOSFET connected in series is used as voltage divider to share the high voltage in order not to damage them. Results: This design is expected to acquire a low-cost generator that can achieve the high voltage pulse in amount of ?1.5 kV with falltime 3 ns and risetime 15 ns into a 50? load that will be used for nsPEFs purposes. Further detailed on the circuit design will be explained at presentation.

Sulaeman, M. Y.; Widita, R. [Department of Physics, Nuclear Physics and Biophysics Research Division, Faculty of Mathematics and Natural Science, Institut Teknologi Bandung, Bandung (Indonesia)

2014-09-30T23:59:59.000Z

226

ANUEADflM-31 Electric Power High-Voltage Transmission Lines:  

Office of Scientific and Technical Information (OSTI)

formulated fluid that is kept under high pressure. This fluid helps to dissipate the power loss heat generated by the conductors. The construction costs in 1991 dollars for...

227

Acceleration Factors for Damp-Heat and HAST with High Voltage...  

Broader source: Energy.gov (indexed) [DOE]

High PID Resistant Cross-Linked Encapsulnt Based on Polyolefin SOLAR ASCE Comparing Accelerated Testing and Outdoor Exposure Agenda for the PV Module Reliability Workshop,...

228

Peak Power Bi-directional Transfer From High Speed Flywheel to Electrical Regulated Bus Voltage System  

E-Print Network [OSTI]

were performed to determine the energy transfer capabilities of a flywheel coupled high speed permanent magnet synchronous machine through the proposed system's energy storage tank. Results are presented

Szabados, Barna

229

Table 1. Design specifications of ultra-high speed PM motor. Supply voltage (V) 12  

E-Print Network [OSTI]

) 1500 Rated torque (Nm) 0.0955 Rated speed (r/min) 150,000 Stator Core Permanent Magnet Shaft Coil Analysis of Ultra-High Speed Permanent-Magnet Motor Masaru Kano, and Toshihiko Noguchi Department@vos.nagaokaut.ac.jp Abstract This paper describes a design of an ultra-high speed (UHS) permanent-magnet (PM) synchronous motor

Fujimoto, Hiroshi

230

A High-Frequency Resonant Inverter Topology With Low-Voltage Stress  

E-Print Network [OSTI]

This paper presents a new switched-mode resonant inverter, which we term the inverter, that is well suited to operation at very high frequencies and to rapid on/off control. Features of this inverter topology include low ...

Rivas, Juan M.

231

Reduction of interference on substation low voltage wiring  

SciTech Connect (OSTI)

This paper describes test results and mitigation methods of electromagnetic interference (EMI) on control and low voltage circuits in substations caused by air disconnect switch operation. The tests are focused on a comparison between unshielded and shielded circuits from capacitively coupled voltage transformers (CCVT) and other equipment circuits in the vicinity. New test data are presented comparing unshielded and shielded cables and transient currents on all connections to the CCVT including the pedestal and ground strap. The paper gives a practical and understandable explanation of the causes of EMI in substations and how shielded cable and parallel ground conductors reduce interference. Design guidelines are listed in the Conclusion.

Gavazza, R.J. [Pacific Gas and Electric Co., San Francisco, CA (United States)] [Pacific Gas and Electric Co., San Francisco, CA (United States); Wiggins, C.M. [Carl M. Wiggins and Associates, Friendswood, TX (United States)] [Carl M. Wiggins and Associates, Friendswood, TX (United States)

1996-07-01T23:59:59.000Z

232

Charge-pump voltage converter  

DOE Patents [OSTI]

A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

Brainard, John P. (Albuquerque, NM); Christenson, Todd R. (Albuquerque, NM)

2009-11-03T23:59:59.000Z

233

Proceedings of the seventh international conference on high voltage electron microscopy  

SciTech Connect (OSTI)

Eight-four papers are arranged under the following headings: high resolution, techniques and instrumentation, radiation effects, in-situ and phase transformations, minerals and ceramics, and semiconductors and thin films. Twenty-three papers were abstracted separately for the data base; three of the remainder had previously been abstracted. (DLC)

Fisher, R.M.; Gronsky, R.; Westmacott, K.H. (eds.)

1983-01-01T23:59:59.000Z

234

Ames Lab 101: Reinventing the Power Cable  

ScienceCinema (OSTI)

Ames Laboratory researchers are working to develop new electrical power cables that are stronger and lighter than the cables currently used in the nation's power grid. Nano Tube animation by Iain Goodyear

Russell, Alan

2014-06-04T23:59:59.000Z

235

Design optimization of cable-stayed bridges  

E-Print Network [OSTI]

The goal of this thesis is to achieve a basic understanding of cable-stayed systems. Issues to be treated are the diachronic evolution of cable-stayed bridges, including the advantages, the limitations and the basic design ...

Bessas, Georgios

2006-01-01T23:59:59.000Z

236

Multi-frequency cable vibration experiments  

E-Print Network [OSTI]

A series of Multi-Frequency cable vibration experiments at Reynolds number 7600 were carried out at the MIT Tow Tank using the Virtual Cable Towing Apparatus (VCTA). Motions observed in a Direct Numerical Simulation of a ...

Wiggins, Andrew (Andrew Dale)

2005-01-01T23:59:59.000Z

237

Ames Lab 101: Reinventing the Power Cable  

SciTech Connect (OSTI)

Ames Laboratory researchers are working to develop new electrical power cables that are stronger and lighter than the cables currently used in the nation's power grid. Nano Tube animation by Iain Goodyear

Russell, Alan

2013-09-27T23:59:59.000Z

238

High Voltage Electrolytes for Li-ion Batteries | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensional Subject:Ground Hawaii HIGH PERFORMANCEDOE Biomass Program2 DOE

239

Epidemiologic study of Holstein dairy cow performance and reproduction near a high-voltage direct - current powerline  

SciTech Connect (OSTI)

The development and operation of a high-voltage direct-current (HVDC) transmission line in rural Minnesota generated public concern over potential adverse effects to nearby residents and their livestock. Electrical parameters near an HVDC line decline rapidly with distance, but effects on ambient space charge have been detected out to 1 mile. To identify potential adverse effects of HVDC line operation on livestock, case-control and cohort study methods were used to examine various indices of Holstein performance in relation to distance from the line and the onset of line operation. It was believed that these indices would reflect changes in physiologic function or overt health effects that might arise from the HVDC environment. High-quality performance data from existing Dairy Herd Improvement Association (DHIA) records were obtained for 97% of qualifying herds located within 10 miles of the line. The large number of animals and years of observation provided high statistical power to detect even small systematic changes in performance. No significant differences in milk production or reproductive capacity were associated with presumed exposure to the HVDC environment. The absence of measurable effects in a large sentinel animal population may have implications for the assessment of human health risks related to HVDC transmission lines.

Martin, F.B.; Bender, A.; Steuernagel, G.; Robinson, R.A.; Revsbech, R.; Sorensen, D.K.; Williamson, N.; Williams, A.

1986-01-01T23:59:59.000Z

240

From: Laurie Smith To: Congestion Study Comments Subject: High Voltage Transmission Lines  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensional Electrical Resistivityconnie0:59 PM I34Keryn Newman To:High

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

High Voltage Electrolytes for Li-ion Batteries | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensional Subject:Ground Hawaii HIGH PERFORMANCEDOE Biomass Program2 DOE1

242

High Voltage Electrolytes for Li-ion Batteries | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensional Subject:Ground Hawaii HIGH PERFORMANCEDOE Biomass Program2 DOE109

243

Low Voltage High-SNR Pipeline Data Converters Charles Myers, Jipeng Li, Dong-Young Chang, and Un-Ku Moon  

E-Print Network [OSTI]

Low Voltage High-SNR Pipeline Data Converters Charles Myers, Jipeng Li, Dong-Young Chang, and Un pipeline data converter. This is accomplished with the removal of the S/H input stage and the use of a rail limitations. In pipeline data converters, noise reduction options such as oversampling and noise shaping

Moon, Un-Ku

244

Experimental and theoretical studies of a high temperature cesium-barium tacitron, with application to low voltage-high current inversion. Final report, April 1, 1993--February 28, 1994  

SciTech Connect (OSTI)

A low voltage/high current switch refer-red as ``Cs-Ba tacitron`` is studied for use as a dc to ac inverter in high temperature and/or ionizing radiation environments. The operational characteristics of the Cs-Ba tacitron as a switch were investigated experimentally in three modes: (a) breakdown mode, (b) I-V mode, and (c) current modulation mode. Operation parameters measured include switching frequencies up to 20 kHz, hold-off voltages up to 200 V, current densities in excess of 15 A/CM{sup 2}, switch power density of 1 kW/cm{sup 2}, and a switching efficiency in excess of 90 % at collector voltages greater than 30 V. Also, if the discharge current is circuit limited to a value below the maximum thermal emission current density, the voltage drop is constant and below 3 V.

Murray, C.S.; El-Genk, M.S.

1994-02-01T23:59:59.000Z

245

Grain growth behavior of Pb-Cu-Te cable sheathing alloys  

SciTech Connect (OSTI)

Lead alloys are extensively used as sheathing material for power and telecommunication cables. Excellent extrusion properties, high ductility, extremely low recrystallization temperature, good fatigue and creep resistance, make these alloys ideal for cable sheathing application. Though the thickness of the lead sheath is only a few hundred {mu}m, it is a critical component of the cable. The lead layer in the cable is often the limiting factor both during the cable production and during its service phase. Up to several hundred miles of long single piece cables may be required for underground and underwater cables. Cracking in the lead sheath during the cable sheathing extrusion limits the production of such long cables while cracking of the lead sheath due to repeated vibration, creep and recrystallization limits the service life of these cables. The purpose of the present research is to increase the duration of cable extrusion time without compromising sheath integrity by minimizing deleterious precipitate formation and growth. Concentrations of Cu and Te in the commercial alloy are too small to contribute to precipitation strengthening. Therefore their positive influence on mechanical strength should mainly result from the influence of Cu and Te in solution on interdiffusivity and grain boundary mobility. The formation of large precipitates observed in Pb-Cu-Te alloys can be minimized and extrusion times increased without negatively affecting mechanical properties if the solute content is reduced to near solid solubility levels. In order to examine the effect of lowering solute content on microstructural stability and mechanical properties, compressive stress-strain behavior of a Pb-50 wt ppm Cu-100 wt ppm Te alloy with solute contents close to the solubility limits and a Pb-400 wt ppm Cu-400 wt ppm Te alloy was examined at room temperature. The grain growth kinetics in these alloys were studied in a temperature range of 100 to 225 C.

Sahay, S.S.; Guruswamy, S. [Univ. of Utah, Salt Lake City, UT (United States). Dept. of Metallurgical Engineering] [Univ. of Utah, Salt Lake City, UT (United States). Dept. of Metallurgical Engineering; Goodwin, F. [International Lead Zinc Research Organization, Research Triangle Park, NC (United States)] [International Lead Zinc Research Organization, Research Triangle Park, NC (United States)

1995-04-01T23:59:59.000Z

246

Magnetic instabilities in Nb3Sn strands and cables  

SciTech Connect (OSTI)

This paper describes a model for calculation of magnetic instabilities in superconducting wires with transport current and reports results of instability simulations in Nb{sub 3}Sn strands from different manufactures. The effect of magnetic instabilities on the strand and cable performance is presented and a criterion for the maximum effective sub-element size of strands for high field magnets is formulated.

Kashikhim, Vadim V.; Zlobin, Alexander V.; /Fermilab

2004-11-01T23:59:59.000Z

247

A wide bandgap silicon carbide (SiC) gate driver for high-temperature and high-voltage applications  

SciTech Connect (OSTI)

Limitations of silicon (Si) based power electronic devices can be overcome with Silicon Carbide (SiC) because of its remarkable material properties. SiC is a wide bandgap semiconductor material with larger bandgap, lower leakage currents, higher breakdown electric field, and higher thermal conductivity, which promotes higher switching frequencies for high power applications, higher temperature operation, and results in higher power density devices relative to Si [1]. The proposed work is focused on design of a SiC gate driver to drive a SiC power MOSFET, on a Cree SiC process, with rise/fall times (less than 100 ns) suitable for 500 kHz to 1 MHz switching frequency applications. A process optimized gate driver topology design which is significantly different from generic Si circuit design is proposed. The ultimate goal of the project is to integrate this gate driver into a Toyota Prius plug-in hybrid electric vehicle (PHEV) charger module. The application of this high frequency charger will result in lighter, smaller, cheaper, and a more efficient power electronics system.

Lamichhane, Ranjan [University of Arkansas; Ericson, Milton Nance [ORNL; Frank, Steven Shane [ORNL; BRITTONJr., CHARLES L. [Oak Ridge National Laboratory (ORNL); Marlino, Laura D [ORNL; Mantooth, Alan [University of Arkansas; Francis, Matt [APEI, Inc.; Shepherd, Dr. Paul [University of Arkansas; Glover, Dr. Michael [University of Arkansas; Podar, Mircea [ORNL; Perez, M [University of Arkansas; Mcnutt, Tyler [APEI, Inc.; Whitaker, Mr. Bret [APEI, Inc.; Cole, Mr. Zach [APEI, Inc.

2014-01-01T23:59:59.000Z

248

Researchers map atomic movements that trigger voltage fade in...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

map atomic movements that trigger voltage fade in high-energy-density batteries January 22, 2015 Voltage and capacity curves from an LMR-NMC high-energy cathode show voltage fade...

249

Voltage controlled current source  

DOE Patents [OSTI]

A seven decade, voltage controlled current source is described for use in testing intermediate range nuclear instruments that covers the entire test current range of from 10 picoamperes to 100 microamperes. High accuracy is obtained throughout the entire seven decades of output current with circuitry that includes a coordinated switching scheme responsive to the input signal from a hybrid computer to control the input voltage to an antilog amplifier, and to selectively connect a resistance to the antilog amplifier output to provide a continuous output current source as a function of a preset range of input voltage. An operator controlled switch provides current adjustment for operation in either a real-time simulation test mode or a time response test mode.

Casne, Gregory M. (Pittsburgh, PA)

1992-01-01T23:59:59.000Z

250

Inner surface flash-over of insulator of low-inductance high-voltage self-breakdown gas switch and its application  

SciTech Connect (OSTI)

In this paper, the inner surface flash-over of high-voltage self-breakdown switch, which is used as a main switch of pulse modulator, is analyzed in theory by employing the method of distributed element equivalent circuit. Moreover, the field distortion of the switch is simulated by using software. The results of theoretical analysis and simulation by software show that the inner surface flash-over usually starts at the junction points among the stainless steel, insulator, and insulation gas in the switch. A switch with improved structure is designed and fabricated according to the theoretical analysis and simulation results. Several methods to avoid inner surface flash-over are used to improve the structure of switch. In experiment, the inductance of the switch is no more than 100 nH, the working voltage of the switch is about 600 kV, and the output voltage and current of the accelerator is about 500 kV and 50 kA, respectively. And the zero-to-peak rise time of output voltage at matched load is less than 30 ns due to the small inductance of switch. The original switch was broken-down after dozens of experiments, and the improved switch has been worked more than 200 times stably.

Zhang, Hong-bo, E-mail: walkman67@163.com; Liu, Jin-liang [College of Opto-electronic Science and Engineering, National University of Defense Technology, Changsha, Hunan 410073 (China)] [College of Opto-electronic Science and Engineering, National University of Defense Technology, Changsha, Hunan 410073 (China)

2014-04-15T23:59:59.000Z

251

Microsoft Word - Cable NDE L3 milestone  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

that can serve as key indicators of cable aging. In parallel, nondestructive evaluation (NDE) measurement methods sensitive to these conditions as well as NDE methods currently...

252

3430 IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, VOL. 61, NO. 8, OCTOBER 2012 Experimental Validation of High-Voltage-Ratio  

E-Print Network [OSTI]

-voltage current-source like device that produces electricity and heat directly from input hydrogen and oxygen carbon dioxide emissions under the assumption that the hydrogen can be produced from renewable-energy sources such as photovoltaic and wind energy or as a subprod- uct of currently wasted energy of large

Simões, Marcelo Godoy

253

Minimizing Simultaneous Switching Noise at Reduced Power with Constant-Voltage Power Transmission Lines for High-Speed Signaling  

E-Print Network [OSTI]

plane structure with a power transmission line (PTL). In this paper, a new power delivery scheme called Constant Voltage Power Transmission Line (CV-PTL) is shown to significantly reduce switching noise while, and measurements. Keywords Power delivery network, simultaneous switching noise, power transmission line 1

Swaminathan, Madhavan

254

Flat-Sag Cables with Semiactive Damping 1 FLAT-SAG CABLES WITH SEMIACTIVE DAMPING  

E-Print Network [OSTI]

the previous work by adding sag, inclination, and axial flexibility to the cable model. The equations of motion by semiactive dampers for a wide range of cable sag and damper location. KEYWORDS semiactive damping, rain-wind to environmental excitations, such as rain-wind induced vibration, and support excitations. Steel cables

Johnson, Erik A.

255

Semiactive Damping of Cables with Sag 1 SEMIACTIVE DAMPING OF CABLES WITH SAG  

E-Print Network [OSTI]

the previous work by adding sag, inclination, and axial flexibility to the cable model. The equations of motion by semiactive dampers for a wide range of cable sag and damper location. KEYWORDS semiactive damping, rain-wind to environmental excitations, such as rain-wind induced vibration, and support excitations. Steel cables

Spencer Jr., B.F.

256

A PC-PCL-based control system for the high-voltage pulsed-power operation of the Intense Diagnostic Neutral Beam (IDNB) Experiment  

SciTech Connect (OSTI)

A stand-alone, semiautomated control system for the high-voltage pulsed-power energy sources on the Intense Diagnostic Neutral Beam Experiment at Los Alamos National Laboratory using personal computer (PC) and programmable logic controller (PLC) technology has been developed and implemented. The control system, consisting of a PC with the graphic operator interface, the network connecting the PC to the PLC, the PLC, the PLC I/O modules, fiber-optic interfaces and software, is described.

Gribble, R.

1993-06-01T23:59:59.000Z

257

Voltage balanced multilevel voltage source converter system  

DOE Patents [OSTI]

A voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means.

Peng, Fang Zheng (Oak Ridge, TN); Lai, Jih-Sheng (Knoxville, TN)

1997-01-01T23:59:59.000Z

258

Voltage balanced multilevel voltage source converter system  

DOE Patents [OSTI]

Disclosed is a voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means. 15 figs.

Peng, F.Z.; Lai, J.S.

1997-07-01T23:59:59.000Z

259

FEM Analysis of Nb-Sn Rutherford-type Cables  

SciTech Connect (OSTI)

An important part of superconducting accelerator magnet work is the conductor. To produce magnetic fields larger than 10 T, brittle conductors are typically used. For instance, for Nb{sub 3}Sn the original round wire, in the form of a composite of Copper, Niobium and Tin, is assembled into a so-called Rutherford-type cable, which is used to wind the magnet. The magnet is then subjected to a high temperature heat treatment to produce the chemical reactions that make the material superconducting. At this stage the superconductor is brittle and its superconducting properties sensitive to strain. This work is based on the development of a 2D finite element model, which simulates the mechanical behavior of Rutherford-type cable before heat treatment. The model was applied to a number of different cable architectures. To validate a critical criterion adopted into the single Nb-Sn wire analysis, the results of the model were compared with those measured experimentally on cable cross sections.

Barzi, Emanuela; Gallo, Giuseppe; Neri, Paolo; /Fermilab

2011-01-01T23:59:59.000Z

260

Silicon-on-insulator-based high-voltage, high-temperature integrated circuit gate driver for silicon carbide-based power field effect transistors  

SciTech Connect (OSTI)

Silicon carbide (SiC)-based field effect transistors (FETs) are gaining popularity as switching elements in power electronic circuits designed for high-temperature environments like hybrid electric vehicle, aircraft, well logging, geothermal power generation etc. Like any other power switches, SiC-based power devices also need gate driver circuits to interface them with the logic units. The placement of the gate driver circuit next to the power switch is optimal for minimising system complexity. Successful operation of the gate driver circuit in a harsh environment, especially with minimal or no heat sink and without liquid cooling, can increase the power-to-volume ratio as well as the power-to-weight ratio for power conversion modules such as a DC-DC converter, inverter etc. A silicon-on-insulator (SOI)-based high-voltage, high-temperature integrated circuit (IC) gate driver for SiC power FETs has been designed and fabricated using a commercially available 0.8--m, 2-poly and 3-metal bipolar-complementary metal oxide semiconductor (CMOS)-double diffused metal oxide semiconductor (DMOS) process. The prototype circuit-s maximum gate drive supply can be 40-V with peak 2.3-A sourcing/sinking current driving capability. Owing to the wide driving range, this gate driver IC can be used to drive a wide variety of SiC FET switches (both normally OFF metal oxide semiconductor field effect transistor (MOSFET) and normally ON junction field effect transistor (JFET)). The switching frequency is 20-kHz and the duty cycle can be varied from 0 to 100-. The circuit has been successfully tested with SiC power MOSFETs and JFETs without any heat sink and cooling mechanism. During these tests, SiC switches were kept at room temperature and ambient temperature of the driver circuit was increased to 200-C. The circuit underwent numerous temperature cycles with negligible performance degradation.

Tolbert, Leon M [ORNL; Huque, Mohammad A [ORNL; Blalock, Benjamin J [ORNL; Islam, Syed K [ORNL

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Pulsed CO{sub 2} laser with an X-ray preioniser based on a high-voltage low-pressure glow discharge  

SciTech Connect (OSTI)

An X-ray preioniser with an electron beam energy density of 0.1 J cm{sup -2} based on a high-voltage (20 - 40 kV) low-pressure glow discharge is developed for repetitively pulsed gas lasers. The electron concentration in the CO{sub 2} - N{sub 2} - He mixture as a function of the voltage across the preioniser is calculated for titanium and other foils. The preioniser can be operated both in a single-pulse regime and at pulse repetition rates ranging up to hundreds of Hertz. A specific energy yield of 51 J L{sup -1} is achieved in the X-ray preionised pulsed CO{sub 2} atmospheric-pressure laser. This preioniser was shown to be efficient for other active media (CO and excimer lasers), which opens up new opportunities for the development of repetitively pulsed gas lasers. (lasers)

Oreshkin, V F; Seregin, Aleksandr M; Sinaiskii, V V; Shchetinkina, T A ['Astrofizika' Research and Production Association (Russian Federation); Sorokin, A R [Institute of Semiconductor Physics, Siberian Branch of the Russian Academy of Sciences, Novosibirsk (Russian Federation)

2003-12-31T23:59:59.000Z

262

An Internal Coaxil Cable Seal System  

DOE Patents [OSTI]

The invention is a seal system for a coaxial cable more specifically an internal seal system placed within the coaxial cable and its constituent components. A series of seal stacks including flexible rigid rings and elastomeric rings are placed on load bearing members within the coaxial cable. The current invention is adapted to seal the annular space between the coaxial cable and an electrical contact passing there through. The coaxial cable is disposed within drilling components to transmit electrical signals between drilling components within a drill string. During oil and gas exploration, a drill string can see a range of pressures and temperatures thus resulting in multiple combinations of temperature and pressure and increasing the difficulty of creating a robust seal for all combinations. The seal system can be used in a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David (Lehi, UT); Dahlgren, Scott (Provo, UT); Sneddon, Cameron (Provo, UT); Briscoe, Michael (Lehi, UT); Fox, Joe (Spanish Fork, UT)

2004-12-23T23:59:59.000Z

263

Transient voltage oscillations in coils  

SciTech Connect (OSTI)

Magnet coils may be excited into internal voltage oscillations by transient voltages. Such oscillations may electrically stress the magnet's dielectric components to many times its normal stress. This may precipitate a dielectric failure, and the attendant prolonged loss of service and costly repair work. Therefore, it is important to know the natural frequencies of oscillations of a magnet during the design stage, and to determine whether the expected switching transient voltages can excite the magnet into high-voltage internal oscillations. The series capacitance of a winding significantly affects its natural frequencies. However, the series capacitance is difficult to calculate, because it may comprise complex capacitance network, consisting of intra- and inter-coil turn-to-turn capacitances of the coil sections. A method of calculating the series capacitance of a winding is proposed. This method is rigorous but simple to execute. The time-varying transient voltages along the winding are also calculated.

Chowdhuri, P.

1985-01-01T23:59:59.000Z

264

> REPLACE THIS LINE WITH YOUR PAPER IDENTIFICATION NUMBER (DOUBLE-CLICK HERE TO EDIT) < 1 Abstract--In high current, high voltage, high temperature  

E-Print Network [OSTI]

and high current applications, such as HVDC transmission [1] or pulsed power application [2], a thyristor

Paris-Sud XI, Université de

265

Department of Mechanical Engineering Spring 2012 Synthetic Cable Termination  

E-Print Network [OSTI]

PENNSTATE Department of Mechanical Engineering Spring 2012 Synthetic Cable Termination Overview to be grasped. The methods for terminating the metallic cable will not work with the synthetic cable, so a new termination method is needed. The synthetic cable is a new design that has yet to be successfully terminated

Demirel, Melik C.

266

Condition Monitoring of Cables Task 3 Report: Condition Monitoring Techniques for Electric Cables  

SciTech Connect (OSTI)

For more than 20 years the NRC has sponsored research studying electric cable aging degradation, condition monitoring, and environmental qualification testing practices for electric cables used in nuclear power plants. This report summarizes several of the most effective and commonly used condition monitoring techniques available to detect damage and measure the extent of degradation in electric cable insulation. The technical basis for each technique is summarized, along with its application, trendability of test data, ease of performing the technique, advantages and limitations, and the usefulness of the test results to characterize and assess the condition of electric cables.

Villaran, M.; Lofaro, R.; na

2009-11-30T23:59:59.000Z

267

Do not exceed the operating input power, voltage, and current level and signal type appropriate for the instrument being used, refer to  

E-Print Network [OSTI]

operation. - Instrument generates high temperature or electrical shock during operation. - Power cable, plug below, immediately terminate operation and disconnect the power cable. Contact your local Agilent;Herstellerbescheinigung GER AUSCHEMISSION LpA Manufacturer

Anlage, Steven

268

High-Temperature Superconductivity Cable Demonstration Projects |  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana.ProgramJulietip sheetK-4In 2013 many| DepartmentAndrea Spikes

269

Section IV.D.3 for DOE 2013 Annual Report: Novel Phosphazene-based Compounds to Enhance Safety and Stability of Cell Chemistries for High Voltage Applications (INL)  

SciTech Connect (OSTI)

Electrolytes play a central role in performance and aging in most electrochemical systems. As automotive and grid applications place a higher reliance on electrochemical stored energy, it becomes more urgent to have electrolyte components that enable optimal battery performance while promoting battery safety and longevity. Safety remains a foremost concern for widespread utilization of Li-ion technology in electric-drive vehicles, especially as the focus turns to higher voltage systems (5V). This work capitalizes on the long established INL expertise regarding phosphazene chemistry, aimed at battery-viable compounds for electrolytes and electrodes that are highly tolerant to abusive conditions. This report showcases our 2013 work for the DOE applied battery research (ABR) program, wherein testing results are summarized for INL electrolytes and alternative anode materials.

Kevin L. Gering; Mason K. Harrup; Eric J. Dufek; Sergiy V. Sazhin; Harry W. Rollins; David K. Jamison; Fred F. Stewart; John Burba

2013-09-01T23:59:59.000Z

270

Automatic voltage imbalance detector  

DOE Patents [OSTI]

A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

Bobbett, Ronald E. (Los Alamos, NM); McCormick, J. Byron (Los Alamos, NM); Kerwin, William J. (Tucson, AZ)

1984-01-01T23:59:59.000Z

271

E-Print Network 3.0 - albany hts cable Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

TechnologyTechnology Summary: Power CablesHTS Electric Power Cables 500 m Cable Test Site in500 m Cable Test Site in Yokosuka... Yokosuka, Japan, Japan 12;2222 HTS...

272

HTS Cable Projects | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of Energy Power.pdf11-161-LNG | Department ofHTS Cable Projects HTS Cable Projects Fact sheet describing

273

An Energy Conservation Program at a Large Cable Manufacturing Plant  

E-Print Network [OSTI]

The Atlanta Works is the largest telephone cable manufacturing plant in the world plus the manufacturing center for fiber optic cable for the Western Electric Company and exemplifies how an effective energy conservation program can work...

Reale, P. J.

1983-01-01T23:59:59.000Z

274

Marine vertical cable multiple attenuation beyond up/down separation  

E-Print Network [OSTI]

Marine vertical cable acquisition is an emerging technology. It represents an alternative to surface seismic acquisition in areas congested by platforms or other obstacles. The vertical cable acquisition consists of recording pressure at several...

Tran, Andre

2001-01-01T23:59:59.000Z

275

Communications Copper Horizontal Cable 27 15 13-1 SECTION 27 15 13  

E-Print Network [OSTI]

/TIA-568-C.2. C. Cable shall be listed by a Nationally Recognized Testing Laboratory (NRTL). D. Cable

Dawson, Clint N.

276

Cable attachment for a radioactive brachytherapy source capsule  

DOE Patents [OSTI]

In cancer brachytherapy treatment, a small californium-252 neutron source capsule is attached to a guide cable using a modified crimping technique. The guide cable has a solid cylindrical end, and the attachment employs circumferential grooves micromachined in the solid cable end. The attachment was designed and tested, and hardware fabricated for use inside a radioactive hot cell. A welding step typically required in other cable attachments is avoided.

Gross, Ian G; Pierce, Larry A

2006-07-18T23:59:59.000Z

277

Apparatus producing constant cable tension for intermittent demand  

DOE Patents [OSTI]

This invention relates to apparatus for producing constant tension in cable or the like when it is unreeled and reeled from a drum or spool under conditions of intermittent demand. The invention is particularly applicable to the handling of superconductive cable, but the invention is also applicable to the unreeling and reeling of other strands, such as electrical cable, wire, cord, other cables, fish line, wrapping paper and numerous other materials.

Lauritzen, T.

1984-05-23T23:59:59.000Z

278

Ignition distributor voltage generator  

SciTech Connect (OSTI)

This patent describes a voltage pulse generator and ignition distributor comprising, a base, a shaft rotatably supported by the base, a distributor cap supported by the base having a center electrode and circumferentially spaced outer electrodes. The pulse generator and ignition distribution also include a first rotor driven by the shaft formed of electrical insulating material having electrically conductive means connected to the center terminal and a portion that rotates past the outer electrodes. The portion of the electrically conductive means that rotates past the outer electrodes is spaced from the outer electrodes to form a gap therebetween. A voltage pulse generator comprises a second rotor driven by the shaft, at least one permanent magnet and an annular pickup coil supported by the base. The pickup coil has inner turns and outer turns, the beginning turn of the inner turns connected to a first lead and the last turn of the outer turns connected to a second lead, the outer turns enclosing the inner turns. The pickup coil also has a circuit connected directly between the second lead and ground which is operative to provide a direct conductive path to ground for high frequency energy capacitively coupled to the outer turns from the gap discharge between the electrically conductive means of the first rotor and an outer electrode, the outer turns forming a grounded shield for the inner turns.

Boyer, J.A.

1986-11-04T23:59:59.000Z

279

Final Report: MATERIALS, STRANDS, AND CABLES FOR SUPERCONDUCTING ACCELERATOR MAGNETS [Grant Number DE-SC0010312  

SciTech Connect (OSTI)

Our program consisted of the two components: Strand Research and Cable Research, with a focus on Nb3Sn, Bi2212, and YBCO for accelerator magnet applications. We demonstrated a method to refine the grains in Nb3Sn by a factor of two, reaching 45 nm grain sizes, and layer Jcs of 6 kA/mm2 at 12 T. W also measured conductor magnetization for field quality. This has been done both with Nb3Sn conductor, as well as Bi:2212 strand. Work in support of quench studies of YBCO coils was also performed. Cable loss studies in Nb3Sn focused on connecting and comparing persistent magnetization and coupling magnetization for considering their relative impact on HEP machines. In the area of HTS cables, we have investigated both the quench in multistrand YBCO CORC cables, as well as the magnetization of these cables for use in high field magnets. In addition, we examined the magnetic and thermal properties of large (50 T) solenoids.

Sumption, Mike; Collings, E.

2014-10-29T23:59:59.000Z

280

A 4000-A HVDC (high-voltage direct-current) circuit breaker with fast fault-clearing capability: Final report  

SciTech Connect (OSTI)

This project is a follow-up of the first development of a 500 kV HVDC airblast circuit breaker (EPRI project 1507-3). The objective was to increase the current interrupting capability from 2200 A to 4000 A and shorten its fault clearing time. A high current 500 kV HVDC circuit breaker has been built using the passive commutation circuit. The breaker is modular in construction and can be designed for a wide variety of system conditions. More than 400 current interruptions were carried out successfully. Tests have shown that this circuit breaker is capable of interrupting more than 4000 A dc. Practical breakers with current interrupting capability of even 5500 A dc could be built. The circuit breaker operation and the fault-clearing process can be materially speeded up if the trip signal is given as soon as the fault is detected and without waiting for the current levels to come down in response to converter control action. The new dc breakers are shown to be capable of withstanding these transient arc currents of 8000 A without affecting its ability to interrupt the direct current that follows the transient. This transient current withstand capability is greater than is likely to occur during dc faults. The fault clearing time of this HVDC circuit breaker is comparable to the fault clearing time of conventional ac breakers for ac faults. The developed HVDC circuit breaker is now commercially available and can be supplied for use in HVDC systems. Its use in such systems is expected to provide flexibility in system design and contribute to system stability. 38 refs., 52 figs., 9 tabs.

Not Available

1988-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Voltage Control Technical Conference  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Intro Voltage Control Conference - BPA Active Power Control in Wind Parks - Siemens Interconnection Criteria for Frequency Response Requirements - NERC Model Validation...

282

Investigation of the spatiotemporal characteristics of the electric field in the Ne-H{sub 2} plasma of a beam-type high-voltage pulsed discharge  

SciTech Connect (OSTI)

In the present work, the spatiotemporal dynamics of the electric field E(x, t) of plasma produced by a beam-type high-voltage pulsed discharge is investigated. The electric field strength E(x, t) in an accelerating gap and in a plasma flare was determined from the measured Stark splitting of the H{sub ?} hydrogen line. The obtained dependence E(x, t) was used to calculate the electron distribution function and the spectral line intensities in the accelerating gap and in the plasma flare by the method of statistical modeling. The calculated population of He atomic states excited by electron impact and their comparison with the measured spectral line intensities I(?, x, t) demonstrate that a reverse electric field retarding the electron motion and leading to electron beam degradation must be present in the plasma flare near the grid. Measurement of the field strength from the Stark splitting of the H{sub ?} line demonstrates that it can reach considerable values.

Demkin, V. P.; Mel'nichuk, S. V.; Borisov, A. V.; Bardin, S. S. [National Research Tomsk State University, 36, Lenin Ave., 634050 Tomsk (Russian Federation)] [National Research Tomsk State University, 36, Lenin Ave., 634050 Tomsk (Russian Federation)

2013-12-15T23:59:59.000Z

283

Modulated voltage metastable ionization detector  

SciTech Connect (OSTI)

Metastable ionization detectors used for chromatographic analysis usually employa fixed high voltage for the ionization potential. For this reason, the operating range is limited to about three orders of magnitude. By use of the technique disclosed in the instant invention, operating ranges of about nine orders of magnitude are obtained. The output current from a metastable ionization detector (MID) is applied to a modulation voltage circuit. An adjustment is made to balance out the background current, and an output current, above background, is applied to an input of a strip chart recorder. For low level concentrations, i.e., low detected output current, the ionization potential will be at a maximum and the metastable ionization detector will operate at its most sensitive level. When the detected current from the metastable ionization detector increases above a predetermined threshold level, a voltage control circuit is activated which turns on a high voltage transistor which acts to reduce the ionization potential. The ionization potential applied to the metastable ionization detector is then varied so as to maintain the detected signal level constant. The variation in ionization potential is now related to the concentration fo the constituent and a representative amplitude is applied to another input of said strip chart recorder.

Carle, G. C.; Humphry, D. E.; Kojiro, D. R.

1985-08-27T23:59:59.000Z

284

Superconducting Cable Having A Felexible Former  

DOE Patents [OSTI]

In order to provide a flexible oxide superconducting cable which is reduced in AC loss, tape-shaped superconducting wires covered with a stabilizing metal are wound on a flexible former. The superconducting wires are preferably laid on the former at a bending strain of not more than 0.2%. In laying on the former, a number of tape-shaped superconducting wires are laid on a core member in a side-by-side manner, to form a first layer. A prescribed number of tape-shaped superconducting wires are laid on top of the first layer in a side-by-side manner, to form a second layer. The former may be made of a metal, plastic, reinforced plastic, polymer, or a composite and provides flexibility to the superconducting wires and the cable formed therewith.

Hughey, Raburn L. (Franklin, GA); Sinha, Uday K. (Carrollton, GA); Reece, David S. (Carrollton, GA); Muller, Albert C. (Eidson, TN)

2005-03-15T23:59:59.000Z

285

Superconducting Cable Having A Flexible Former  

DOE Patents [OSTI]

In order to provide a flexible oxide superconducting cable which is reduced in AC loss, tape-shaped superconducting wires covered with a stabilizing metal are wound on a flexible former. The superconducting wires are preferably laid on the former at a bending strain of not more than 0.2%. In laying on the former, a number of tape-shaped superconducting wires are laid on a core member in a side-by-side manner, to form a first layer. A prescribed number of tape-shaped superconducting wires are laid on top of the first layer in a side-by-side manner, to form a second layer. The former may be made of a metal, plastic, reinforced plastic, polymer, or a composite and provides flexibility to the superconducting wires and the cable formed therewith.

Hughey, Raburn L. (Franklin, GA); Sinha, Uday K. (Carrollton, GA); Reece, David S. (Carrollton, GA); Muller, Albert C. (Eidson, TN)

2005-08-30T23:59:59.000Z

286

HAWC Calibration: Cabling Experience from HAWC30  

E-Print Network [OSTI]

to the 2"-PVC conduits (TWO on each WCD tank: one for fibers and one for HV cables) are through the field-field-enclosure for the fiber connections to the 2"-PVC conduits? · And how do the CAT5 ca- bles complicate this fur- ther? HAWC) is involved and dangerous and done 4.5m in the air on a ladder! · Left: loosen the bracket securing the PVC

287

Optimal Selection of AC Cables for Large Scale Offshore Wind Farms  

E-Print Network [OSTI]

Optimal Selection of AC Cables for Large Scale Offshore Wind Farms Peng Hou, Weihao Hu, Zhe Chen@et.aau.dk, whu@iet.aau.dk, zch@iet.aau.dk Abstract--The investment of large scale offshore wind farms is high the operational requirements of the offshore wind farms and the connected power systems. In this paper, a new cost

Hu, Weihao

288

A Mixed Model for Real-Time, Interactive Simulation of a Cable Passing Through Several Pulleys  

SciTech Connect (OSTI)

A model of a cable and pulleys is presented that can be used in Real Time Computer Graphics applications. The model is formulated by the coupling of a damped spring and a variable coefficient wave equation, and can be integrated in more complex mechanical models of lift systems, such as cranes, elevators, etc. with a high degree of interactivity.

Garcia-Fernandez, Ignacio; Pla-Castells, Marta; Martinez-Dura, Rafael J. [Instituto de Robotica. Universidad de Valencia (Spain)

2007-09-06T23:59:59.000Z

289

Voltage verification unit  

DOE Patents [OSTI]

A voltage verification unit and method for determining the absence of potentially dangerous potentials within a power supply enclosure without Mode 2 work is disclosed. With this device and method, a qualified worker, following a relatively simple protocol that involves a function test (hot, cold, hot) of the voltage verification unit before Lock Out/Tag Out and, and once the Lock Out/Tag Out is completed, testing or "trying" by simply reading a display on the voltage verification unit can be accomplished without exposure of the operator to the interior of the voltage supply enclosure. According to a preferred embodiment, the voltage verification unit includes test leads to allow diagnostics with other meters, without the necessity of accessing potentially dangerous bus bars or the like.

Martin, Edward J. (Virginia Beach, VA)

2008-01-15T23:59:59.000Z

290

Nuclear power plant cable materials : review of qualification and currently available aging data for margin assessments in cable performance.  

SciTech Connect (OSTI)

A selective literature review was conducted to assess whether currently available accelerated aging and original qualification data could be used to establish operational margins for the continued use of cable insulation and jacketing materials in nuclear power plant environments. The materials are subject to chemical and physical degradation under extended radiationthermal- oxidative conditions. Of particular interest were the circumstances under which existing aging data could be used to predict whether aged materials should pass loss of coolant accident (LOCA) performance requirements. Original LOCA qualification testing usually involved accelerated aging simulations of the 40-year expected ambient aging conditions followed by a LOCA simulation. The accelerated aging simulations were conducted under rapid accelerated aging conditions that did not account for many of the known limitations in accelerated polymer aging and therefore did not correctly simulate actual aging conditions. These highly accelerated aging conditions resulted in insulation materials with mostlyinert' aging processes as well as jacket materials where oxidative damage dropped quickly away from the air-exposed outside jacket surface. Therefore, for most LOCA performance predictions, testing appears to have relied upon heterogeneous aging behavior with oxidation often limited to the exterior of the cable cross-section - a situation which is not comparable with the nearly homogenous oxidative aging that will occur over decades under low dose rate and low temperature plant conditions. The historical aging conditions are therefore insufficient to determine with reasonable confidence the remaining operational margins for these materials. This does not necessarily imply that the existing 40-year-old materials would fail if LOCA conditions occurred, but rather that unambiguous statements about the current aging state and anticipated LOCA performance cannot be provided based on original qualification testing data alone. The non-availability of conclusive predictions for the aging conditions of 40-year-old cables implies that the same levels of uncertainty will remain for any re-qualification or extended operation of these cables. The highly variable aging behavior of the range of materials employed also implies that simple, standardized aging tests are not sufficient to provide the required aging data and performance predictions for all materials. It is recommended that focused studies be conducted that would yield the material aging parameters needed to predict aging behaviors under low dose, low temperature plant equivalent conditions and that appropriately aged specimens be prepared that would mimic oxidatively-aged 40- to 60- year-old materials for confirmatory LOCA performance testing. This study concludes that it is not sufficient to expose materials to rapid, high radiation and high temperature levels with subsequent LOCA qualification testing in order to predictively quantify safety margins of existing infrastructure with regard to LOCA performance. We need to better understand how cable jacketing and insulation materials have degraded over decades of power plant operation and how this aging history relates to service life prediction and the performance of existing equipment to withstand a LOCA situation.

Celina, Mathias Christopher; Gillen, Kenneth Todd; Lindgren, Eric Richard

2013-05-01T23:59:59.000Z

291

Vehicle Technologies Office Merit Review 2014: High Energy Density Li-ion Cells for EV’s Based on Novel, High Voltage Cathode Material Systems  

Broader source: Energy.gov [DOE]

Presentation given by Farasis Energy, Inc. at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about high energy density Li...

292

Choosing Power Cables on the Basis of Energy Economics  

E-Print Network [OSTI]

Technology Conference Houston, TX, April 13-16, 1980 class. CABLE LOSSES AND OPERATING TEMPERATURE If copper losses predominate total losses per unit length are given by q = 3I2r (1) for a three conductor cable where q is cable loss in watts per unit... 1,068 1,641 2,232 2,745 3,360 4,182 5,220 TABLE 1 (Continued) Cable Size Resistance Cable Circular Mil s Ampacity at 65?C n/ Cost $/ Cable # Or (AWG) (amperes) 1000 ft 1000 ft 250,000 6,2109 273 0.050 10 0.042 7,485300,000 304 350,000 8...

Dimachkieh, S.; Brown, D. R.

1980-01-01T23:59:59.000Z

293

Armored spring-core superconducting cable and method of construction  

DOE Patents [OSTI]

An armored spring-core superconducting cable (12) is provided. The armored spring-core superconducting cable (12) may include a spring-core (20), at least one superconducting strand (24) wound onto the spring-core (20), and an armored shell (22) that encases the superconducting strands (24). The spring-core (20) is generally a perforated tube that allows purge gases and cryogenic liquids to be circulated through the armored superconducting cable (12), as well as managing the internal stresses within the armored spring-core superconducting cable (12). The armored shell (22) manages the external stresses of the armored spring-core superconducting cable (12) to protect the fragile superconducting strands (24). The armored spring-core superconducting cable (12) may also include a conductive jacket (34) formed outwardly of the armored shell (22).

McIntyre, Peter M. (611 Montclair, College Station, TX 77840); Soika, Rainer H. (1 Hensel, #X4C, College Station, TX 77840)

2002-01-01T23:59:59.000Z

294

x.0 Handling of White SVT Cables (SVT Excess Cables) before and during Withdrawing of Endcap In general we (UC Santa Cruz) prefer to do all handling of the white SVT cables necessary to withdraw and reinsert  

E-Print Network [OSTI]

13 x.0 Handling of White SVT Cables (SVT Excess Cables) before and during Withdrawing of Endcap In general we (UC Santa Cruz) prefer to do all handling of the white SVT cables necessary to withdraw@scipp.ucsc.edu, office in SC: (831) 459­3337 , extn. at SLAC: 8561. The white SVT cables consist of two parts

California at Santa Cruz, University of

295

Superconducting cable-in-conduit low resistance splice  

DOE Patents [OSTI]

A low resistance splice connects two cable-in-conduit superconductors to each other. Dividing collars for arranging sub-cable units from each conduit are provided, along with clamping collars for mating each sub-cable wire assembly to form mated assemblies. The mated assemblies ideally can be accomplished by way of splicing collar. The mated assemblies are cooled by way of a flow of coolant, preferably helium. A method for implementing such a splicing is also described.

Artman, Thomas A. (Forest, VA)

2003-06-24T23:59:59.000Z

296

aerial cable facility: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

system demonstrate the ability of the designed platform-- Autonomous monitoring, mobile robot, crawler, sensors, underground cables, aging status. I. INTRODUCTION he Mamishev,...

297

Development of scaling rules for Rutherford type superconducting cables  

SciTech Connect (OSTI)

During the R D phase of the Superconducting Supercollider (SSC) program, LBL was responsible for establishing the parameters for cables used in SSC dipole and quadrupole magnets. In addition, the design and fabrication of a new cable for use in the Low Beta Quadrupoles. As a result of the development work on these and other cables, we have arrived a set of scaling rules which provide guidelines for choosing the parameters for a wide range of superconducting cables. These parameters include strand size, strand number, keystone angle, percent compaction, cable pitch and compacted cable dimensions. In addition, we have defined the tolerance ranges for the key cable manufacturing parameters such as mandrel size and shape, stand tension, and Turkshead temperature control. In this paper, we present the results on cables ranging from 8 strands to 36 strands of 0.65mm wire and from 8 strands to 30 strands of 0.8mm wire. We use these results to demonstrate the application of the scaling rules for Rutherford-type cable.

Royet, J.M.; Scanlan, R.M.

1990-09-01T23:59:59.000Z

298

Analysis and design of an electronic voltage ratchet  

E-Print Network [OSTI]

and decay. Impulse voltages are produced through the discharging of 0, capacitor into a shaping network consisting of resistors and a. capacitor as is shown in Figure 2. 9. The operation of the impulse generator is as follows. Capacitor Ci is charged from... voltage shaping network. as possible in order to reduce oscillations in the wavefront and wavetail portions of the impulse voltage [1). The impulse voltage generator requires a, highly charged capacitor or bank of capacitors. Capacitors may be charged...

Menendez, Jorge Carlos

2012-06-07T23:59:59.000Z

299

Heat transfer in forced cooled cables  

SciTech Connect (OSTI)

This paper presents a calculation method for current continuous rating of cable lines that considers the actual environment conditions, such as different types of soil, change of geometrical disposition, etc... This method is based on the resolution in terms of limit differences. The results of a full scale experimental installation, were used to check the theoretical model precision. The comparison between the measured and calculated rise show a difference of 5% in general and a maximum of 7% which may be considered acceptable for line design.

Lombardi, A.; Donazzi, F. (Societa Cavi Pirelli); Taralli, C.; Tencer, C.; Lima, A.J.O. (Pirelli S.A. Cia Indl Brasileira (BR))

1990-01-01T23:59:59.000Z

300

Phase Transitions and High-Voltage Electrochemical Behavior of LiCoO2 Thin Films Grown by Pulsed Laser Deposition  

E-Print Network [OSTI]

Laser Deposition H. Xia,a L. Lu,b,z Y. S. Meng,c and G. Cederc, * a Advanced Materials for Micro behavior of LiCoO2 thin-film cathodes prepared by pulsed laser deposition are studied for charging voltages- discharge curves. Ex situ X-ray diffraction measurements confirm structural changes and a phase transition

Ceder, Gerbrand

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Microsoft Word - CFN_CSD_Cabling_Infrastructure_v1.1.docx  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

commissioning of the cabling systems above are also in the scope of this contract. The supplier shall provide a warranty for the installed cabling systems. Cable trays are out...

302

Submerged Medium Voltage Cable Systems at Nuclear Power Plants: A Review of  

Office of Scientific and Technical Information (OSTI)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartmentNationalRestart of theResourcecomments/rss enExpansion ofMaximumresearchSteven

303

Insight into the Atomic Structure of High-Voltage Spinel 2 LiNi0.5Mn1.5O4 Cathode Material  

DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

Application of high-voltage spinel LiNi0.5Mn1.5O4 cathode material is the closest and the most realistic approach to meeting the midterm goal of lithium-ion batteries for electric vehicles (EVs) and plug-in hybrid electric vehicles (HEVs). However, this application has been hampered by long-standing issues, such as capacity degradation and poor first-cycle Coulombic efficiency of LiNi0.5Mn1.5O4 cathode material. Although it is well-known that the structure of LiNi0.5Mn1.5O4 into which Li ions are reversibly intercalated plays a critical role in the above issues, performance degradation related to structural changes, particularly in the first cycle, are not fully understood. Here, we report detailed investigations of local atomic-level and average structure of LiNi0.5Mn1.5O4 during first cycle (3.5–4.9 V) at room temperature. We observed two types of local atomic-level migration of transition metals (TM) ions in the cathode of a well-prepared LiNi0.5Mn1.5O4//Li half-cell during first charge via an aberration-corrected scanning transmission electron microscopy (STEM). Surface regions (~2 nm) of the cycled LiNi0.5Mn1.5O4 particles show migration of TM ions into tetrahedral Li sites to form a Mn3O4-like structure. However, subsurface regions of the cycled particles exhibit migration of TM ions into empty octahedral sites to form a rocksalt-like structure. The migration of these TM ions are closely related to dissolution of Ni/Mn ions and building-up of charge transfer impedance, which contribute significantly to the capacity degradation and the poor first-cycle Coulombic efficiency of spinel LiNi0.5Mn1.5O4 cathode material. Accordingly, we provide suggestions of effective stabilization of LiNi0.5Mn1.5O4 structure to obtain better electrochemical performance.

Huang, Xuejie [Chinese Academy of Sciences, Beijing (China); Yu, Xiqian [Brookhaven National Laboratory (BNL), Upton, NY (United States); Lin, Mingxiang [Chinese Academy of Sciences, Beijing (China); Ben, Liubin [Chinese Academy of Sciences, Beijing (China); Sun, Yang [Chinese Academy of Sciences, Beijing (China); Wang, Hao [Chinese Academy of Sciences, Beijing (China); Yang, Zhenzhong [Chinese Academy of Sciences, Beijing (China); Gu, Lin [Chinese Academy of Sciences, Beijing (China); Yang, Xiao -Qing [Brookhaven National Laboratory (BNL), Upton, NY (United States); Zhao, Haofei [Chinese Academy of Sciences, Beijing (China); Yu, Richeng [Chinese Academy of Sciences, Beijing (China); Armand, Michel [CIC Energigune, Alava (Spain)

2015-01-13T23:59:59.000Z

304

UITV University of Iowa Cable Television ITS VIDEO SERVICES  

E-Print Network [OSTI]

UITV ­ University of Iowa Cable Television ITS VIDEO SERVICES 1 UITV Telecommunication and Network Services ITS Video Services 23 Lindquist Center 319-335-5898 UITV, University of Iowa Cable Television Operations Report Calendar Year 2006 February 12, 2007 ­ Michael J. McBride, Video Services Program Manager

305

Critical Current Measurements of the Main LHC Superconducting Cables  

E-Print Network [OSTI]

For the main dipole and quadrupole magnets of the LHC, CERN has ordered from industry about 7000 km of superconducting Nb-Ti Rutherford type cables, delivered between 1999 and 2005. The strands of these cables are produced by six different companies, and cabled on five different machines. In the framework of the US contribution to the LHC, BNL has been testing and analyzing the electrical properties of samples of these cables. The main purpose of these tests was to qualify the critical current of the entire cable production in the frame of the quality assurance program implemented by CERN to assure the overall strand and cable performances. In total more than 2100 cable samples have been evaluated at 4.3 K in terms of critical current $I_{C}$, n-value and the residual resistance ratio, RRR. This paper will present an overview of the results, and show the correlations of the critical current and n-value between virgin strands, extracted strands, and cables. Also described are correlations of $I_{C}$ measured a...

Verweij, A P

2007-01-01T23:59:59.000Z

306

Proposal of a method for real cables EMC  

E-Print Network [OSTI]

Proposal of a method for real cables EMC modeling Olivier Maurice 23. juillet 2008 Abstract TThis paper deals with a method for the real cables EMC (ElectroMagnetic Compatibility) modeling compatibility (EMC). The objective is firstly to take into account the continuous interlacing of the wires

Boyer, Edmond

307

Mechanical design of submarine power cables for floating platforms  

SciTech Connect (OSTI)

The process of mechanical design of submarine power cables employed by the Simplex Wire and Cable Company is described. The process commences with design criteria and proceeds through preliminary design, load and stress analyses and culminates in extreme value reliability and lifetime predictions. The analytical methods employed are emphasized and some representative numerical results are presented.

Bisplinghoff, R. L.; Libby, D. O.; Costantino, R. W.

1980-01-01T23:59:59.000Z

308

Microsoft Word - SAND2013-2448P - FY13Q2 Field Aged Cable Assesment...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

but could be confirmed at a later date) cable (bonded jacketinsulation) from the Zion Nuclear Power Station. Physical property testing was performed on the as received cables....

309

Field corrosion testing and performance of cable shielding materials in soils  

SciTech Connect (OSTI)

This article discusses the importance of corrosion resistance in cable-shielding materials, describes the mechanisms of shielding corrosion that occur in buried telephone cable, and evaluates the results of the six-year REA Horry Cooperative buried telephone cable corrosion test. In this study, both active and static cables were included. Withdrawals were made over a six-year period. These cables were evaluated for cable-shielding corrosion. Special attention was paid to the comparative behavior of active and static cables. Results indicate that steel shieldings are most susceptible to the effects of alternating current (AC) in active cables. Results of a wide range of shieldings are presented and evaluated.

Haynes, G.; Baboian, R. (Texas Instruments Inc., Electrochemical and Corrosion Lab., 34 Forest St., Mail Station 10-13, Attleboro, MA (US))

1989-09-01T23:59:59.000Z

310

E-Print Network 3.0 - actin cable architecture Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

cable architecture Search Powered by Explorit Topic List Advanced Search Sample search results for: actin cable architecture Page: << < 1 2 3 4 5 > >> 1 Journal of Integrative...

311

Electro-optical voltage sensor head  

DOE Patents [OSTI]

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Idaho Falls, ID)

1998-01-01T23:59:59.000Z

312

Electron launching voltage monitor  

DOE Patents [OSTI]

An electron launching voltage monitor measures MITL voltage using a relationship between anode electric field and electron current launched from a cathode-mounted perturbation. An electron launching probe extends through and is spaced from the edge of an opening in a first MITL conductor, one end of the launching probe being in the gap between the MITL conductor, the other end being adjacent a first side of the first conductor away from the second conductor. A housing surrounds the launching probe and electrically connects the first side of the first conductor to the other end of the launching probe. A detector detects the current passing through the housing to the launching probe, the detected current being representative of the voltage between the conductors. 5 figs.

Mendel, C.W.; Savage, M.E.

1992-03-17T23:59:59.000Z

313

Low voltage arc formation in railguns  

DOE Patents [OSTI]

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, R.S.

1985-08-05T23:59:59.000Z

314

Low voltage arc formation in railguns  

DOE Patents [OSTI]

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile. 2 figs.

Hawke, R.S.

1987-11-17T23:59:59.000Z

315

Low voltage arc formation in railguns  

DOE Patents [OSTI]

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, Ronald S. (Livermore, CA)

1987-01-01T23:59:59.000Z

316

FEMCAM Analysis of SULTAN Test Results for ITER Nb3SN Cable-conduit Conductors  

SciTech Connect (OSTI)

Performance degradation due to filament fracture of Nb3 Sn cable-in-conduit conductors (CICCs) is a critical issue in large-scale magnet designs such as ITER which is currently being constructed in the South of France. The critical current observed in most SULTAN TF CICC samples is significantly lower than expected and the voltage-current characteristic is seen to have a much broader transition from a single strand to the CICC. Moreover, most conductors exhibit the irreversible degradation due to filament fracture and strain relaxation under electromagnetic cyclic loading. With recent success in monitoring thermal strain distribution and its evolution under the electromagnetic cyclic loading from in situ measurement of critical temperature, we apply FEMCAM which includes strand filament breakage and local current sharing effects to SULTAN tested CICCs to study Nb3 Sn strain sensitivity and irreversible performance degradation. FEMCAM combines the thermal bending effect during cool down and the EM bending effect due to locally accumulating Lorentz force during magnet operation. It also includes strand filament fracture and related local current sharing for the calculation of cable n value. In this paper, we model continuous performance degradation under EM cyclic loading based on strain relaxation and the transition broadening upon cyclic loading to the extreme cases seen in SULTAN test data to better quantify conductor performance degradation.

Yuhu Zhai, Pierluigi Bruzzone, Ciro Calzolaio

2013-03-19T23:59:59.000Z

317

Apparatus and method for fabricating multi-strand superconducting cable  

DOE Patents [OSTI]

Multi-strand superconducting cables adapted to be used, for example, to wind a magnet is fabricated by directing wire strands inwardly from spools disposed on the perimeter of a rotating disk and wrapping them diagonally around a tapered mandrel with a flattened cross-sectional shape with a core having a wedge-shaped channel. As the cable is pulled axially, flexibly coupled wedge-shaped pieces are continuously passed through the channel in the mandrel and inserted into the cable as an internal support therefor.

Borden, Albert R. (El Cerrito, CA)

1986-01-01T23:59:59.000Z

318

Method for fabricating multi-strand superconducting cable  

DOE Patents [OSTI]

Multi-strand superconducting cables adapted to be used, for example, to wind a magnet are fabricated by directing wire strands inwardly from spools disposed on the perimeter of a rotating disk and wrapping them diagonally around a tapered mandrel with a flattened cross-sectional shape with a core having a wedge-shaped channel. As the cable is pulled axially, flexibly coupled wedge-shaped pieces are continuously passed through the channel in the mandrel and inserted into the cable as an internal support therefor.

Borden, A.R.

1985-04-01T23:59:59.000Z

319

Concept of Quasi-Capacitive Tapping of Bipolar Voltage-Controlled Oscillators  

E-Print Network [OSTI]

Concept of Quasi-Capacitive Tapping of Bipolar Voltage-Controlled Oscillators Aleksandar Tasic the active part of the oscillator and the LC-tank, as proposed in this paper, the voltage swing over the tank of high- performance bipolar voltage-controlled oscillators (VCO's). As the voltage-controlled oscillators

Serdijn, Wouter A.

320

An Internal Coaxial Cable Electrical Connector For Use In Downhole Tools  

DOE Patents [OSTI]

A coaxial cable electrical connector more specifically an internal coaxial cable connector placed within a coaxial cable and its constituent components. A coaxial cable connector is in electrical communcation with an inductive transformer and a coaxial cable. The connector is in electrical communication with the outer housing of the inductive transfonner. A generally coaxial center conductor, a portion of which could be the coil in the inductive transformer, passes through the connector, is electrically insulated from the connector, and is in electrical communication with the conductive care of the coaxial cable. A plurality of bulbous pliant tabs on the coaxial cable connector mechanically engage the inside diameter of the coaxial cable thus grounding the transformer to the coaxial cable. The coaxial cable and inductive transformer are disposed within downhole tools to transmit electrical signals between downhole tools within a drill string.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David S. (Lehi, UT); Dahlgren, Scott (Provo, UT); Fox, Joe (Spanish Fork, UT); Sneddon, Cameron (Provo, UT); Briscoe, Michael (Lehi, UT)

2005-11-29T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Determining Remaining Useful Life of Aging Cables in Nuclear...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3624 Determining Remaining Useful Life of Aging Cables in Nuclear Power Plants - Interim Status for FY2014 Milestone Report M3LW-140R04022 September 2014 KL Simmons AM Jones LS...

322

The Electrical Resistance of Rutherford-Type Superconducting Cable Splices  

E-Print Network [OSTI]

The electrical resistance of Large Hadron Collider main busbar cable lap splices produced by soft soldering has been measured with two independent methods as a function of intercable contact area and for splices made of cables with various defects. For defect-free lap splices, the resistance increases from 0.3 to 10 n? (at 4.3 K in self-field) when reducing the cable overlap length from 120 to 3 mm, as expected assuming that the resistance is inversely proportional to the intercable contact area. The resistance of bridge splices that connect side-by-side cables can be predicted from the lap splice resistances and the overlap areas involved.

Heck, C; Fleiter, J; Bottura, L

2015-01-01T23:59:59.000Z

323

Wave excited cable mooring dynamics by modal analysis  

E-Print Network [OSTI]

klAVE EXCITED CABLE MOORING DYNAMICS BY MODAL ANALYSIS A Thesis RICHARD EARL DAVIS Submitted to the Graduate College of Texas A&M University in partial fulfillment of the requirement for the degree of MASTER OF SCIENCE December 1977 Major... Subject: Civil Engineering WAVE EXCITED CABLE MOORING DYNAMICS BY MODAL ANALYSIS A Thesis by RICHARD EARL DAVIS Approved as to style and content by: (:( '. t(( (Co ? Chairman of Committee) 0~s (Co-Chairnin+of Committee) (Head of' Departme t...

Davis, Richard Earl

2012-06-07T23:59:59.000Z

324

INTEGRATED GHz VOLTAGE CONTROLLED OSCILLATORS  

E-Print Network [OSTI]

INTEGRATED GHz VOLTAGE CONTROLLED OSCILLATORS Peter Kinget Bell Labs - Lucent Technologies Murray Hill, NJ (USA) Abstract The voltage controlled oscillator (VCO) is a critical sub. We focus on the de- sign of a critical sub-block: the voltage controlled oscillator (VCO). We review

Kinget, Peter

325

Michael Scholl, mss4@wustl.edu (A paper written under the guidance of Prof. Raj Jain) Download High availability is one of the major goals of smart grid systems. This paper examines the availability of wind turbines, a high voltage DC (HVDC)  

E-Print Network [OSTI]

the availability of wind turbines, a high voltage DC (HVDC) transmission system, and a supervisory control and data of a Wind Turbine 3.2 Availability Data 3.3 Sensitivity Analysis 4. HVDC Transmission System 4.1 Parts of a HVDC Transmission System 4.2 Availability Data 4.3 Sensitivity Analysis 5. Control System 5.1 Parts

Jain, Raj

326

Electro-optic voltage sensor for sensing voltage in an E-field  

DOE Patents [OSTI]

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Idaho Falls, ID); Renak, Todd W. (Idaho Falls, ID)

1999-01-01T23:59:59.000Z

327

Electro-optic voltage sensor for sensing voltage in an E-field  

DOE Patents [OSTI]

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages is disclosed. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam`s polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured. 18 figs.

Woods, G.K.; Renak, T.W.

1999-04-06T23:59:59.000Z

328

Sequential circuit design for radiation hardened multiple voltage integrated circuits  

DOE Patents [OSTI]

The present invention includes a radiation hardened sequential circuit, such as a bistable circuit, flip-flop or other suitable design that presents substantial immunity to ionizing radiation while simultaneously maintaining a low operating voltage. In one embodiment, the circuit includes a plurality of logic elements that operate on relatively low voltage, and a master and slave latches each having storage elements that operate on a relatively high voltage.

Clark, Lawrence T. (Phoenix, AZ); McIver, III, John K. (Albuquerque, NM)

2009-11-24T23:59:59.000Z

329

Design and applications of a flicker voltage generator  

SciTech Connect (OSTI)

In this paper, a 200W flicker voltage generator is made by using microcomputers and linear amplification circuits. The modulation amplitudes and frequencies based on the UIE {Delta}V{sub 10} evaluation can be arbitrarily assigned by software with high accuracy. The flicker voltage signals measured at the customer side also can be re-generated. Some applications, such as evaluating the effects of flicker voltage on incandescent and compact fluorescent lamps (CFLs), are also made. From experimental tests by use of the flicker voltage generator, the properties of some compact fluorescent lamps and incandescent lamps are compared. Those properties describe the relation between input voltage variation and output flux of lamps, such that there is direct description of influences of flicker voltages on lamps.

Chang, W.N.; Wu, C.J. [National Taiwan Inst. of Tech., Peitow-Taipei (Taiwan, Province of China). Dept. of Electrical Engineering

1995-12-31T23:59:59.000Z

330

Triple voltage dc-to-dc converter and method  

DOE Patents [OSTI]

A circuit and method of providing three dc voltage buses and transforming power between a low voltage dc converter and a high voltage dc converter, by coupling a primary dc power circuit and a secondary dc power circuit through an isolation transformer; providing the gating signals to power semiconductor switches in the primary and secondary circuits to control power flow between the primary and secondary circuits and by controlling a phase shift between the primary voltage and the secondary voltage. The primary dc power circuit and the secondary dc power circuit each further comprising at least two tank capacitances arranged in series as a tank leg, at least two resonant switching devices arranged in series with each other and arranged in parallel with the tank leg, and at least one voltage source arranged in parallel with the tank leg and the resonant switching devices, said resonant switching devices including power semiconductor switches that are operated by gating signals. Additional embodiments having a center-tapped battery on the low voltage side and a plurality of modules on both the low voltage side and the high voltage side are also disclosed for the purpose of reducing ripple current and for reducing the size of the components.

Su, Gui-Jia (Knoxville, TN)

2008-08-05T23:59:59.000Z

331

REFINED RFP LOOP VOLTAGE CALCULATION J.C. Sprott  

E-Print Network [OSTI]

is the stored magnetic energy, Up is the plasma energy, and 'E is the global energy confinement time, which-of-merit for RFP devices is the loop voltage. Low loop voltage implies high plasma temperature and long energy is smallest if the loop is as close to the outside of the shell and as far from the primary windings

Sprott, Julien Clinton

332

Ultrasonic signatures of idealized grout defects in polyethylene-sleeved cable stays  

E-Print Network [OSTI]

. These cable stays contain an annular layer of portland cement grout which surrounds the steel cable strands, and provides corrosion protection to the cables. During the grouting operation there is a possibility that voids may form in the grout layer and act...-type of cable-stayed bridge are as shown in Figure 4n". Problem Statement The typical arrangement of a cable stay consists of a steel multistrand cable encased in a polyethylene (PE) pipe, and grouted with portland cement or epoxy grout. Each strand in turn...

Nakirekanti, Sreenivas

1992-01-01T23:59:59.000Z

333

Integrated head package cable carrier for a nuclear power plant  

DOE Patents [OSTI]

A cabling arrangement is provided for a nuclear reactor located within a containment. Structure inside the containment is characterized by a wall having a near side surrounding the reactor vessel defining a cavity, an operating deck outside the cavity, a sub-space below the deck and on a far side of the wall spaced from the near side, and an operating area above the deck. The arrangement includes a movable frame supporting a plurality of cables extending through the frame, each connectable at a first end to a head package on the reactor vessel and each having a second end located in the sub-space. The frame is movable, with the cables, between a first position during normal operation of the reactor when the cables are connected to the head package, located outside the sub-space proximate the head package, and a second position during refueling when the cables are disconnected from the head package, located in the sub-space. In a preferred embodiment, the frame straddles the top of the wall in a substantially horizontal orientation in the first position, pivots about an end distal from the head package to a substantially vertically oriented intermediate position, and is guided, while remaining about vertically oriented, along a track in the sub-space to the second position.

Meuschke, Robert E. (Monroeville, PA); Trombola, Daniel M. (Murrysville, PA)

1995-01-01T23:59:59.000Z

334

Humidity, Temperature, and Voltage (Presentation)  

SciTech Connect (OSTI)

An update is given on the work of the PV Quality Assurance Task Force; Group 3: studying the effects of humidity, temperature, and voltage bias.

Wohlgemuth, J.

2012-03-01T23:59:59.000Z

335

Apparatus producing constant cable tension for intermittent demand  

DOE Patents [OSTI]

The disclosed apparatus produces constant tension in superconducting electrical cable, or some other strand, under conditions of intermittent demand, as the cable is unreeled from a reel or reeled thereon. The apparatus comprises a pivotally supported swing frame on which the reel is rotatably supported, a rotary motor, a drive train connected between the motor and the reel and including an electrically controllable variable torque slip clutch, a servo transducer connected to the swing frame for producing servo input signals corresponding to the position thereof, a servo control system connected between the transducer and the clutch for regulating the torque transmitted by the clutch to maintain the swing frame in a predetermined position, at least one air cylinder connected to the swing frame for counteracting the tension in the cable, and pressure regulating means for supplying a constant air pressure to the cylinder to establish the constant tension in the cable, the servo system and the clutch being effective to produce torque on the reel in an amount sufficient to provide tension in the cable corresponding to the constant force exerted by the air cylinder. The drive train also preferably includes a fail-safe brake operable to its released position by electrical power in common with the servo system, for preventing rotation of the reel if there is a power failure. A shock absorber and biasing springs may also be connected to the swing frame, such springs biasing the frame toward its predetermined position. The tension in the cable may be measured by force measuring devices engageable with the bearings for the reel shaft, such bearings being supported for slight lateral movement. The reel shaft is driven by a Shmidt coupler which accommodates such movement.

Lauritzen, Ted (Lafayette, CA)

1985-01-01T23:59:59.000Z

336

New protection method for HVDC lines including cables  

SciTech Connect (OSTI)

For the third project of the Hokkaido-Honshu HVDC Link in Japan, called the HVDC Link III project (rated at 250 kVdc-1,200 A-300 MW), the authors developed an HVDC transmission line protection method based on a new working principle that allows high-speed and highly sensitive detection of faults, enhancing reliability in the supply of electric power. In general, increasing the sensitivity of relays will lead to an increased likelihood of undesired operation whereas lowering the sensitivity will impair the responsiveness of the relays. The proposed method meets these apparently incompatible requirements very well. Basically classified as a differential scheme, the HVDC transmission line protection method compensates for a charging and discharging current that flows through the line-to-ground capacitance at times of voltage variations caused by a line fault or by the operation of dc power systems. The developed protection method is also characterized in that it uses current changes induced by voltage variations to restrain the operation of a relay. This configuration has made the proposed method far superior in responsiveness and sensitivity to the conventional protection method. A simulation using an EMTP (Electro-Magnetic Transients Program) was conducted on this method. Developed relay equipment embodying the new protection method was subjected to various verification tests, where this equipment was connected to a power system simulator, before being delivered to the HVDC Link III facility.

Takeda, H.; Ayakawa, H.; Tsumenaga, N.; Sanpei, M.

1995-10-01T23:59:59.000Z

337

Amendment to LM-07-12 for Fiber Optic Cable Trenching at the...  

Energy Savers [EERE]

Amendment to LM-07-12 for Fiber Optic Cable Trenching at the Westminster, Colorado, Office Amendment to LM-07-12 for Fiber Optic Cable Trenching at the Westminster, Colorado,...

338

Aalborg Universitet Line Differential Protection Scheme Modelling for Underground 420 kV Cable Systems  

E-Print Network [OSTI]

system transients, transmission cable systems, protection and HVDC-VSC. E-mail: clb@et.aau.dk. desired

Bak, Claus Leth

339

LM139/LM239/LM339/LM2901/LM3302 Low Power Low Offset Voltage Quad Comparators  

E-Print Network [OSTI]

LM139/LM239/LM339/LM2901/LM3302 Low Power Low Offset Voltage Quad Comparators General Description The LM139 series consists of four independent precision voltage comparators with an offset voltage clock timers; multivibrators and high voltage digital logic gates. The LM139 series was designed

Lanterman, Aaron

340

PARTIAL DISCHARGE TESTING OF DEFECTIVE THREE-PHASE PILC CABLE UNDER RATED CONDITIONS  

E-Print Network [OSTI]

PARTIAL DISCHARGE TESTING OF DEFECTIVE THREE-PHASE PILC CABLE UNDER RATED CONDITIONS J. A. Hunter 1 lifespan. An increase in the failure rates of paper insulated lead covered (PILC) cables that make up is to document the effects of mechanical stress on the generation of partial discharge (PD) for cables of PILC

Southampton, University of

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

HIDDEN DAMAGE DETECTION FOR MAIN CABLES OF SUSPENSION BRIDGES INCORPORATING DC MAGNETIZATION WITH A SEARCH COIL-  

E-Print Network [OSTI]

with artificially inflicted broken wires. KEYWORDS : Cable NDE, Search coil, Total flux, DC magnetization, Damage. To overcome this limitation, this study proposes a noncontact cable inspection system incorporating been applied for the inspection of steel cables for ski lifts, elevators, and for other applications

Boyer, Edmond

342

Electromagnetic interference with electronic apparatus by switching surges in GIS-cable system  

SciTech Connect (OSTI)

Thyristor malignitions and protector relay failures caused by GCB closing in the GIS of a cable system could not be controlled by reducing the ground impedance or adding surge absorbing capacitors. As a result, a study was carried out on this problem with a 66kV mock-up apparatus installed in a factory. It was found that malignitions and failures such as mentioned above could be controlled by preventing 10MHz ultra high-frequency surges emitted by the GIS from leaking out into the grounding system.

Nishiwaki, S.; Nojima, K.; Tatara, S.; Kosakada, M.; Tanabe, N.; Yanabu, S. [Toshiba Corp., Kawasaki (Japan)] [Toshiba Corp., Kawasaki (Japan)

1995-04-01T23:59:59.000Z

343

UITV University of Iowa Cable Television ITS VIDEO SERVICES  

E-Print Network [OSTI]

UITV ­ University of Iowa Cable Television ITS VIDEO SERVICES 1 UITV Report for Fiscal Year July 1 and Student Video Productions. o Programs are received from satellite programming services, like SCOLA foreign a venue for student programming, like Daily Iowan Television News and Student Video Productions. · On July

344

Intrinsic Surface Stability in LiMn2-xNix04-s (x = 0.45, 0.5) High Voltage Spinel Materials for Lithium Ion Batteries  

SciTech Connect (OSTI)

This work reports the surface stability of the high vollage Li ion cathode LiMn2_,Ni,Ooh\\ (x = 0.5, 0.45) by comparing thin fi lm and powder composite electrodes after cycling using X-ray photoelectron spectroscopy. The thin film electrodes offer the abili ty to probe the surface of the material without the need of a conductive agent and polymer binder typically used in composite electrodes. The resulls suggest that neither oxidation of PP6 to POF3 nor the decomposition of ethylene carbonate or dimethylene carbonate occurs on the surface of the spinel material. These resulls confirm the enhanced cycling stability and rate capability associated with the high vollage spinel material and suggests that the SE!IIayer fonns due to the reaction of electrochemically inactive components in composite electrodes with the electrolyte.

Carroll, Kyler J [University of California, San Diego; Yang, Ming-Che [University of Florida, Gainesville; Veith, Gabriel M [ORNL; Dudney, Nancy J [ORNL; Meng, Ying Shirley [University of California, San Diego

2012-01-01T23:59:59.000Z

345

Local Dynamic Reactive Power for Correction of System Voltage Problems  

SciTech Connect (OSTI)

Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results are also provided and discussed. The simulations and testing show that local voltage control from DER can prevent local voltage collapse. The results also show that the control can be provided so quickly, within 0.5 seconds, that is does not interfere with conventional utility methods.

Kueck, John D [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Xu, Yan [ORNL; Li, Huijuan [University of Tennessee, Knoxville (UTK); Adhikari, Sarina [ORNL; Irminger, Philip [ORNL

2008-12-01T23:59:59.000Z

346

Low voltage nonprimary explosive detonator  

DOE Patents [OSTI]

A low voltage, electrically actuated, nonprimary explosive detonator is disclosed wherein said detonation is achieved by means of an explosive train in which a deflagration-to-detonation transition is made to occur. The explosive train is confined within a cylindrical body and positioned adjacent to low voltage ignition means have electrical leads extending outwardly from the cylindrical confining body. Application of a low voltage current to the electrical leads ignites a self-sustained deflagration in a donor portion of the explosive train which then is made to undergo a transition to detonation further down the train.

Dinegar, Robert H. (Los Alamos, NM); Kirkham, John (Newbury, GB2)

1982-01-01T23:59:59.000Z

347

The vertical voltage termination technique characterizations of single die multiple 600V power  

E-Print Network [OSTI]

The vertical voltage termination technique ­ characterizations of single die multiple 600V power.grenoble-inp.fr Abstract-- Deep trench terminations are commonly known as a technique to achieve ideal breakdown voltages for high voltage devices. This paper presents the use of deep trench terminations as an original concept

Paris-Sud XI, Université de

348

Fast Optimization of Nano-CMOS Voltage-Controlled Oscillator using Polynomial Regression and Genetic Algorithm  

E-Print Network [OSTI]

Fast Optimization of Nano-CMOS Voltage-Controlled Oscillator using Polynomial Regression in a current-starved 50nm voltage-controlled oscillator (VCO). Accurate polynomial-regression based models have-CMOS), Voltage-Controlled Oscillator (VCO). 1. Introduction Digital design exploration and optimization is highly

Mohanty, Saraju P.

349

Multipoint Pressure and Temperature Sensing Fiber Optic Cable for Monitoring CO2 Sequestration  

SciTech Connect (OSTI)

This report describes the work completed on contract DE-FE0010116. The goal of this two year project was to develop and demonstrate in the laboratory a highly accurate multi-point pressure measurement fiber optic cable based on MEMS pressure sensors suitable for downhole deployment in a CO2 sequestration well. The sensor interrogator was also to be demonstrated in a remote monitoring system and environmental testing was to be completed to indicate its downhole survivability over a lengthy period of time (e.g., 20 years). An interrogator system based on a pulsed laser excitation was shown to be capable of multiple (potentially 100+) simultaneous sensor measurements. Two sensors packages were completed and spliced in a cable onto the same fiber and measured. One sensor package was subsequently measured at high temperatures and pressures in supercritical CO2, while the other package was measured prior and after being subjected to high torque stresses to mimic downhole deployment. The environmental and stress tests indicated areas in which the package design should be further improved.

Challener, William

2014-12-31T23:59:59.000Z

350

Voltage tunable microwave ferrite resonator  

E-Print Network [OSTI]

A novel method of implementing a tunable resonator using an applied voltage is presented. Stress is used to tune a microstrip resonator fabricated on a polycrystalline ferrite substrate. The stress was applied either ...

Oates, Daniel E.

351

Saving Megawatts with Voltage Optimization  

E-Print Network [OSTI]

that had been installed at several electric utility distribution substations in the U.S. and Canada. These systems, being operated in Conservation Voltage Regulation mode, have provided significant energy conservation where they have been installed...

Wilson, T.; Bell, D.

2010-01-01T23:59:59.000Z

352

Langmuir probe measurements in a time-fluctuating-highly ionized non-equilibrium cutting arc: Analysis of the electron retarding part of the time-averaged current-voltage characteristic of the probe  

SciTech Connect (OSTI)

This work describes the application of Langmuir probe diagnostics to the measurement of the electron temperature in a time-fluctuating-highly ionized, non-equilibrium cutting arc. The electron retarding part of the time-averaged current-voltage characteristic of the probe was analysed, assuming that the standard exponential expression describing the electron current to the probe in collision-free plasmas can be applied under the investigated conditions. A procedure is described which allows the determination of the errors introduced in time-averaged probe data due to small-amplitude plasma fluctuations. It was found that the experimental points can be gathered into two well defined groups allowing defining two quite different averaged electron temperature values. In the low-current region the averaged characteristic was not significantly disturbed by the fluctuations and can reliably be used to obtain the actual value of the averaged electron temperature. In particular, an averaged electron temperature of 0.98 ± 0.07 eV (= 11400 ± 800 K) was found for the central core of the arc (30 A) at 3.5 mm downstream from the nozzle exit. This average included not only a time-average over the time fluctuations but also a spatial-average along the probe collecting length. The fitting of the high-current region of the characteristic using such electron temperature value together with the corrections given by the fluctuation analysis showed a relevant departure of local thermal equilibrium in the arc core.

Prevosto, L.; Mancinelli, B. [Grupo de Descargas Eléctricas, Departamento Ing. Electromecánica, Facultad Regional Venado Tuerto (UTN), Laprida 651, Venado Tuerto (2600) Santa Fe (Argentina)] [Grupo de Descargas Eléctricas, Departamento Ing. Electromecánica, Facultad Regional Venado Tuerto (UTN), Laprida 651, Venado Tuerto (2600) Santa Fe (Argentina); Kelly, H. [Grupo de Descargas Eléctricas, Departamento Ing. Electromecánica, Facultad Regional Venado Tuerto (UTN), Laprida 651, Venado Tuerto (2600) Santa Fe (Argentina) [Grupo de Descargas Eléctricas, Departamento Ing. Electromecánica, Facultad Regional Venado Tuerto (UTN), Laprida 651, Venado Tuerto (2600) Santa Fe (Argentina); Instituto de Física del Plasma (CONICET), Departamento de Física, Facultad de Ciencias Exactas y Naturales (UBA) Ciudad Universitaria Pab. I, 1428 Buenos Aires (Argentina)

2013-12-15T23:59:59.000Z

353

Static Analysis of the Lumped Mass Cable Model Using a Shooting Algorithm  

SciTech Connect (OSTI)

This paper focuses on a method to solve the static configuration for a lumped mass cable system. The method demonstrated here is intended to be used prior to performing a dynamics simulation of the cable. Conventional static analysis approaches resort to dynamics relaxation methods or root-finding algorithms (such as the Newton-Raphson method) to find the equilibrium profile. The alternative method demonstrated here is general enough for most cable configurations (slack or taut) and ranges of cable elasticity. The forces acting on the cable are attributable to elasticity, weight, buoyancy, and hydrodynamics. For the three-dimensional problem, the initial cable profile is obtained by solving three equations, regardless of the cable discretization resolution. This analysis discusses regions and circumstances under which failures in the method are encountered.

Masciola, M. D.; Nahon, M.; Driscoll, F. R.

2012-03-01T23:59:59.000Z

354

Multilevel cascade voltage source inverter with seperate DC sources  

DOE Patents [OSTI]

A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations.

Peng, Fang Zheng (Oak Ridge, TN); Lai, Jih-Sheng (Knoxville, TN)

1997-01-01T23:59:59.000Z

355

Multilevel cascade voltage source inverter with separate DC sources  

DOE Patents [OSTI]

A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations. 15 figs.

Peng, F.Z.; Lai, J.S.

1997-06-24T23:59:59.000Z

356

Multilevel cascade voltage source inverter with seperate DC sources  

DOE Patents [OSTI]

A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations.

Peng, Fang Zheng (Knoxville, TN); Lai, Jih-Sheng (Blacksburg, VA)

2002-01-01T23:59:59.000Z

357

Cable Hot Shorts and Circuit Analysis in Fire Risk Assessment  

SciTech Connect (OSTI)

Under existing methods of probabilistic risk assessment (PRA), the analysis of fire-induced circuit faults has typically been conducted on a simplistic basis. In particular, those hot-short methodologies that have been applied remain controversial in regards to the scope of the assessments, the underlying methods, and the assumptions employed. To address weaknesses in fire PRA methodologies, the USNRC has initiated a fire risk analysis research program that includes a task for improving the tools for performing circuit analysis. The objective of this task is to obtain a better understanding of the mechanisms linking fire-induced cable damage to potentially risk-significant failure modes of power, control, and instrumentation cables. This paper discusses the current status of the circuit analysis task.

LaChance, Jeffrey; Nowlen, Steven P.; Wyant, Frank

1999-05-19T23:59:59.000Z

358

Method and device for tensile testing of cable bundles  

DOE Patents [OSTI]

A standard tensile test device is improved to accurately measure the mechanical properties of stranded cables, ropes, and other composite structures wherein a witness is attached to the top and bottom mounting blocks holding the cable under test. The witness is comprised of two parts: a top and a bottom rod of similar diameter with the bottom rod having a smaller diameter stem on its upper end and the top rod having a hollow opening in its lower end into which the stem fits forming a witness joint. A small gap is present between the top rod and the larger diameter portion of the bottom rod. A standard extensometer is attached to the top and bottom rods of the witness spanning this small witness gap. When a force is applied to separate the mounting blocks, the gap in the witness expands the same length that the entire test specimen is stretched.

Robertson, Lawrence M; Ardelean, Emil V; Goodding, James C; Babuska, Vit

2012-10-16T23:59:59.000Z

359

Electro-optic voltage sensor with Multiple Beam Splitting  

DOE Patents [OSTI]

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID)

2000-01-01T23:59:59.000Z

360

Electro-optic voltage sensor with beam splitting  

DOE Patents [OSTI]

The invention is a miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware typically found in the prior art. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID)

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Voltage, energy and power in electric circuits  

E-Print Network [OSTI]

Voltage, energy and power in electric circuits Science teaching unit #12;Disclaimer The Department-2008DVD-EN Voltage, energy and power in electric circuits #12;#12;© Crown copyright 2008 1The National Strategies | Secondary Voltage, energy and power in electric circuits 00094-2008DVD-EN Contents Voltage

Berzins, M.

362

Lockout device for high voltage circuit breaker  

SciTech Connect (OSTI)

An improved lockout assembly is provided for a circuit breaker to lock the switch handle into a selected switch position. The lockout assembly includes two main elements, each having a respective foot for engaging a portion of the upper housing wall of the circuit breaker. The first foot is inserted into a groove in the upper housing wall, and the second foot is inserted into an adjacent aperture (e.g., a slot) in the upper housing wall. The first foot is slid under and into engagement with a first portion, and the second foot is slid under and into engagement with a second portion of the upper housing wall. At the same time the respective two feet are placed in engagement with the respective portions of the upper housing wall, two holes, one on each of the respective two main elements of the assembly, are placed in registration; and a locking device, such as a special scissors equipped with a padlock, is installed through the registered holes to secure the lockout assembly on the circuit breaker. When the lockout assembly of the invention is secured on the circuit breaker, the switch handle of the circuit breaker is locked into the selected switch position and prevented from being switched to another switch position.

Kozlowski, L.J.; Shirey, L.A.

1993-01-26T23:59:59.000Z

363

Lockout device for high voltage circuit breaker  

DOE Patents [OSTI]

An improved lockout assembly is provided for a circuit breaker to lock the switch handle into a selected switch position. The lockout assembly includes two main elements, each having a respective foot for engaging a portion of the upper housing wall of the circuit breaker. The first foot is inserted into a groove in the upper housing wall, and the second foot is inserted into an adjacent aperture (e.g., a slot) in the upper housing wall. The first foot is slid under and into engagement with a first portion, and the second foot is slid under and into engagement with a second portion of the upper housing wall. At the same time the repsective two feet are placed in engagement with the respective portions of the upper housing wall, two holes, one on each of the respective two main elements of the assembly, are placed in registration; and a locking device, such as a special scissors equipped with a padlock, is installed through the registered holes to secure the lockout assembly on the circuit breaker. When the lockout assembly of the invention is secured on the circuit breaker, the switch handle of the circuit breaker is locked into the selected switch position and prevented from being switched to another switch position.

Kozlowski, Lawrence J. (New Kensington, PA); Shirey, Lawrence A. (North Huntingdon, PA)

1993-01-01T23:59:59.000Z

364

Lookout device for high voltage circuit breaker  

SciTech Connect (OSTI)

An improved lockout assembly is provided for a circuit breaker to lock the switch handle into a selected switch position. The lockout assembly includes two main elements, each having a respective foot for engaging a portion of the upper housing wall of the circuit breaker. The first foot is inserted into a groove in the upper housing wall, and the second foot is inserted into an adjacent aperture (e.g., a slot) in the upper housing wall. The first foot is slid under and into engagement with a first portion, and the second foot is slid under and into engagement with a second portion of the upper housing wall. At the same time the respective two feet are placed in engagement with the respective portions of the upper housing wall, two holes, one on each of the respective two main elements of the assembly, are placed in registration; and a locking device, such as a special scissors equipped with a padlock, is installed through the registered holes to secure the lockout assembly on the circuit breaker. When the lockout assembly of the invention is secured on the circuit breaker, the switch handle of the circuit breaker is locked into the selected switch position and prevented from being switched to another switch position.

Kozlowski, L.J.; Shirey, L.A.

1991-12-31T23:59:59.000Z

365

Optically initiated silicon carbide high voltage switch  

DOE Patents [OSTI]

An improved photoconductive switch having a SiC or other wide band gap substrate material, such as GaAs and field-grading liners composed of preferably SiN formed on the substrate adjacent the electrode perimeters or adjacent the substrate perimeters for grading the electric fields.

Caporaso, George J. (Livermore, CA); Sampayan, Stephen E. (Manteca, CA); Sullivan, James S. (Livermore, CA); Sanders; David M. (Livermore, CA)

2011-02-22T23:59:59.000Z

366

Production of high voltage by ion bombardment  

E-Print Network [OSTI]

in nuclear fusion. It is a way for the eAiciency of mirror reactors to be increased by recovering the charged particles that escape. : ' ln 1944, E. P. Wigner first proposed using fission fragments for direct energy conversion. There were several.... ' Recently the idea of direct energy conversion has been revisited. The United States Department of Energy (US DOE) has begun a Nuclear Energy Research Initiative (NERI) project on methods of direct energy conversion in fission reactors. One of the systems...

Phinney, Lucas Carter

2003-01-01T23:59:59.000Z

367

High voltage photo switch package module  

DOE Patents [OSTI]

A photo-conductive switch package module having a photo-conductive substrate or wafer with opposing electrode-interface surfaces, and at least one light-input surface. First metallic layers are formed on the electrode-interface surfaces, and one or more optical waveguides having input and output ends are bonded to the substrate so that the output end of each waveguide is bonded to a corresponding one of the light-input surfaces of the photo-conductive substrate. This forms a waveguide-substrate interface for coupling light into the photo-conductive wafer. A dielectric material such as epoxy is then used to encapsulate the photo-conductive substrate and optical waveguide so that only the metallic layers and the input end of the optical waveguide are exposed. Second metallic layers are then formed on the first metallic layers so that the waveguide-substrate interface is positioned under the second metallic layers.

Sullivan, James S; Sanders, David M; Hawkins, Steven A; Sampayan, Stephen E

2014-02-18T23:59:59.000Z

368

Polymerizable Additive for Passivating High Voltage Cathodes  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsrucLas ConchasPassive Solar Home Design Passive SolarCenterYou areConstructionA Polymerizable

369

Electro-optic voltage sensor head  

DOE Patents [OSTI]

The invention is an electro-optic voltage sensor head designed for integration with existing types of high voltage transmission and distribution apparatus. The sensor head contains a transducer, which comprises a transducing material in which the Pockels electro-optic effect is observed. In the practice of the invention at least one beam of electromagnetic radiation is routed into the transducing material of the transducer in the sensor head. The beam undergoes an electro-optic effect in the sensor head when the transducing material is subjected to an E-field. The electro-optic effect is observed as a differential phase a shift, also called differential phase modulation, of the beam components in orthogonal planes of the electromagnetic radiation. In the preferred embodiment the beam is routed through the transducer along an initial axis and then reflected by a retro-reflector back substantially parallel to the initial axis, making a double pass through the transducer for increased measurement sensitivity. The preferred embodiment of the sensor head also includes a polarization state rotator and at least one beam splitter for orienting the beam along major and minor axes and for splitting the beam components into two signals which are independent converse amplitude-modulated signals carrying E-field magnitude and hence voltage information from the sensor head by way of optic fibers.

Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Woods, Gregory K. (Cornelius, OR)

1999-01-01T23:59:59.000Z

370

Electro-optic voltage sensor head  

DOE Patents [OSTI]

The invention is an electro-optic voltage sensor head designed for integration with existing types of high voltage transmission and distribution apparatus. The sensor head contains a transducer, which comprises a transducing material in which the Pockels electro-optic effect is observed. In the practice of the invention at least one beam of electromagnetic radiation is routed into the transducing material of the transducer in the sensor head. The beam undergoes an electro-optic effect in the sensor head when the transducing material is subjected to an E-field. The electro-optic effect is observed as a differential phase a shift, also called differential phase modulation, of the beam components in orthogonal planes of the electromagnetic radiation. In the preferred embodiment the beam is routed through the transducer along an initial axis and then reflected by a retro-reflector back substantially parallel to the initial axis, making a double pass through the transducer for increased measurement sensitivity. The preferred embodiment of the sensor head also includes a polarization state rotator and at least one beam splitter for orienting the beam along major and minor axes and for splitting the beam components into two signals which are independent converse amplitude-modulated signals carrying E-field magnitude and hence voltage information from the sensor head by way of optic fibers. 6 figs.

Crawford, T.M.; Davidson, J.R.; Woods, G.K.

1999-08-17T23:59:59.000Z

371

E-Print Network 3.0 - active load voltage Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Page: << < 1 2 3 4 5 > >> 41 Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power Filter Applications Summary: Performance Analysis of a...

372

Ancillary service details: Voltage control  

SciTech Connect (OSTI)

Voltage control is accomplished by managing reactive power on an alternating-current power system. Reactive power can be produced and absorbed by both generation and transmission equipment. Reactive-power devices differ substantially in the magnitude and speed of response and in their capital costs. System operators, transmission owners, generators, customers, power marketers, and government regulators need to pay close attention to voltage control as they restructure the U.S. electricity industry. Voltage control can affect reliability and commerce in three ways: (1) Voltages must be maintained within an acceptable range for both customer and power-system equipment to function properly. (2) The movement of reactive power consumes transmission resources, which limits the ability to move real power and worsens congestion. (3) The movement of reactive power results in real-power losses. When generators are required to supply excessive amounts of reactive power, their real-power production must be curtailed. These opportunity costs are not currently compensated for in most regions. Current tariffs are based on embedded costs. These embedded-cost tariffs average about $0.51/MWh, equivalent to $1.5 billion annually for the United States as a whole. Although this cost is low when compared with the cost of energy, it still aggregates to a significant amount of money. This report takes a basic look at why the power system requires reactive power (an appendix explains the fundamentals of real and reactive power). The report then examines the various types of generation and transmission resources used to supply reactive power and to control voltage. Finally it discusses how these resources are deployed and paid for in several reliability regions around the country. As the U.S. electricity industry is restructured, the generation, transmission, and system-control equipment and functions that maintain voltages within the appropriate ranges are being deintegrated.

Kirby, B.; Hirst, E.

1997-12-01T23:59:59.000Z

373

Determining Remaining Useful Life of Aging Cables in Nuclear Power Plants – Interim Study FY13  

SciTech Connect (OSTI)

The most important criterion for cable performance is its ability to withstand a design-basis accident. With nearly 1000 km of power, control, instrumentation, and other cables typically found in an NPP, it would be a significant undertaking to inspect all of the cables. Degradation of the cable jacket, electrical insulation, and other cable components is a key issue that is likely to affect the ability of the currently installed cables to operate safely and reliably for another 20 to 40 years beyond the initial operating life. The development of one or more nondestructive evaluation (NDE) techniques and supporting models that could assist in determining the remaining life expectancy of cables or their current degradation state would be of significant interest. The ability to nondestructively determine material and electrical properties of cable jackets and insulation without disturbing the cables or connections has been deemed essential. Currently, the only technique accepted by industry to measure cable elasticity (the gold standard for determining cable insulation degradation) is the indentation measurement. All other NDE techniques are used to find flaws in the cable and do not provide information to determine the current health or life expectancy. There is no single NDE technique that can satisfy all of the requirements needed for making a life-expectancy determination, but a wide range of methods have been evaluated for use in NPPs as part of a continuous evaluation program. The commonly used methods are indentation and visual inspection, but these are only suitable for easily accessible cables. Several NDE methodologies using electrical techniques are in use today for flaw detection but there are none that can predict the life of a cable. There are, however, several physical and chemical ptoperty changes in cable insulation as a result of thermal and radiation damage. In principle, these properties may be targets for advanced NDE methods to provide early warning of aging and degradation. Examples of such key indicators include changes in chemical structure, mechanical modulus, and dielectric permittivity. While some of these indicators are the basis of currently used technologies, there is a need to increase the volume of cable that may be inspected with a single measurement, and if possible, to develop techniques for in-situ inspection (i.e., while the cable is in operation). This is the focus of the present report.

Simmons, Kevin L.; Fifield, Leonard S.; Westman, Matthew P.; Ramuhalli, Pradeep; Pardini, Allan F.; Tedeschi, Jonathan R.; Jones, Anthony M.

2013-09-27T23:59:59.000Z

374

Circuit bridging of digital equipment caused by smoke from a cable fire  

SciTech Connect (OSTI)

Advanced reactor systems are likely to use protection systems with digital electronics that ideally should be resistant to environmental hazards, including smoke from possible cable fires. Previous smoke tests have shown that digital safety systems can fail even at relatively low levels of smoke density and that short-term failures are likely to be caused by circuit bridging. Experiments were performed to examine these failures, with a focus on component packaging and protection schemes. Circuit bridging, which causes increased leakage currents and arcs, was gauged by measuring leakage currents among the leads of component packages. The resistance among circuit leads typically varies over a wide range, depending on the nature of the circuitry between the pins, bias conditions, circuit board material, etc. Resistance between leads can be as low as 20 k{Omega} and still be good, depending on the component. For these tests, the authors chose a printed circuit board and components that normally have an interlead resistance above 10{sup 12} {Omega}, but if the circuit is exposed to smoke, circuit bridging causes the resistance to fall below 10{sup 3} {Omega}. Plated-through-hole (PTH) and surface-mounted (SMT) packages were exposed to a series of different smoke environments using a mixture of environmentally qualified cables for fuel. Conformal coatings and enclosures were tested as circuit protection methods. High fuel levels, high humidity, and high flaming burns were the conditions most likely to cause circuit bridging. The inexpensive conformal coating that was tested - an acrylic spray - reduced leakage currents, but enclosure in a chassis with a fan did not. PTH packages were more resistant to smoke-induced circuit bridging than SMT packages. Active components failed most often in tests where the leakage currents were high, but failure did not always accompany high leakage currents.

Tanaka, T.J.; Anderson, D.J.

1997-03-01T23:59:59.000Z

375

An Adaptive Voltage Control Algorithm with Multiple Distributed Energy  

SciTech Connect (OSTI)

Distributed energy resources (DE) with power electronics (PE) interfaces with the right control are capable of providing reactive power related ancillary services. Voltage regulation in particular has drawn much attention. In this paper the challenges to control multiple DEs to regulate the local voltage in distribution systems is addressed and a decentralized adaptive voltage control method is proposed. The simulation results in different system conditions show that this adaptive voltage control method is capable of satisfying the fast response speed requirement without causing oscillation or instability of the system. Since this method has high tolerance to the shortage of the system parameters and can be widely adaptive to the variable operation situations of the power systems, it is very suited for the utility application.

Li, Huijuan [University of Tennessee, Knoxville (UTK); Li, Fangxing [ORNL; Adhikari, Sarina [ORNL; Xu, Yan [ORNL; Rizy, D Tom [ORNL; Kueck, John D [ORNL

2009-01-01T23:59:59.000Z

376

SEMIACTIVE DAMPING OF CABLES WITH SAG E.A. Johnson,1 R.E. Christenson,2 and B.F. Spencer, Jr.2  

E-Print Network [OSTI]

the previous work by adding sag, inclination, and axial flexibility to the cable model. The equa- tions damping, cable galloping, rain-wind induced vibration, cable sag, structural control INTRODUCTION Cables structures. These cables are subject to environmental excitations, such as rain-wind induced vibration

Johnson, Erik A.

377

E-Print Network 3.0 - aluminum-stabilized superconducting cables...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

New superconducting technology will help America reduce the demand for additional electric power Summary: ,000-amp, 3-phase superconducting cable at American Electric Power's...

378

Design and performance relationships for cable distribution in multi-story office buildings.  

E-Print Network [OSTI]

??Weaknesses associated with cable distribution systems suggest a lack of design consideration in the planning stage of a building. The primary question to be addressed… (more)

Ryan, Richard Cecil

2012-01-01T23:59:59.000Z

379

Complete Fiber/Copper Cable Solution for Long-Term Temperature...  

Broader source: Energy.gov (indexed) [DOE]

| US DOE Geothermal Program eere.energy.gov Talented technical team - Specialty fiber optics development, testing, and production - Downhole cable and tool development and...

380

Onset voltage of corona on coated conductors  

SciTech Connect (OSTI)

This paper is aimed for investigating the effect of surface coating on the positive and negative onset voltages of corona from stressed conductor as a pre-requisite for onset-voltage calculation. The electric field is accurately calculated by the charge simulation technique. The calculated onset voltages agreed satisfactorily with those measured experimentally for bare conductors. The effect of coating-layer thickness and permittivity as well as conductor radius and height on the onset-voltage values is discussed.

Abdel-Salam, M. [Assiut Univ. (Egypt). Electrical Engineering Dept.; Abo-Shal, Y. [SCECO-East, Dammam (Saudi Arabia). Electrical Engineering Div.

1995-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Direct perturbation analysis on cables with concentrated loads P. Yu *, K. Pan  

E-Print Network [OSTI]

cables, overhead transmission lines, etc. The study of vibrations of suspended cables is of great is the galloping of overhead transmission lines which may cause severe disruptions in the electrical supply and even a cas- cading collapse of a lineÃ?s supporting towers. * Corresponding author. Tel.: +1

Yu, Pei

382

System vendor Contents Type Location Removal of Misc Cable, Conduit and Junction Boxes  

E-Print Network [OSTI]

System vendor Contents Type Location Removal of Misc Cable, Conduit and Junction Boxes in the NCSX;System vendor Contents Type Location Installation for NCSX Power Cables Procedure Procedure Files IP Procedure Procedure Files IP-NCSX-2972 #12;System vendor Contents Type Location Coils NCSX Coil System DC

Princeton Plasma Physics Laboratory

383

Mathematical modeling of electromagnetic wave propagation in heterogeneous lossy coaxial cables with  

E-Print Network [OSTI]

]. However, as pointed Defect Piezo-electric sensor Co-axial cable Piezo-electric sensor Co-axial cable the Project team POEMS of INRIA and the laboratory LIST of CEA Saclay. The general objective of this collaboration has been the nu- merical simulation of piezo-electric sensors used for non destructive testing

Boyer, Edmond

384

K.K. Gan IPRD06 1 Bandwidths of Micro Twisted-Pair Cables  

E-Print Network [OSTI]

A or more What is rise/fall time after irradiation? What is optical power after irradiation? What currentK.K. Gan IPRD06 1 Bandwidths of Micro Twisted-Pair Cables and Fusion Spliced SIMM-GRIN Fibers Introduction Bandwidth of micro twisted-pair cables Bandwidth of fusion spliced SIMM-GRIN fibers Radiation

Gan, K. K.

385

Effort on Developing Cabled Ocean Observatories Research Assitant, Institute of Mechatronics Control Engineering, Zhejiang University  

E-Print Network [OSTI]

of Mechatronics Control Engineering, Zhejiang University Post-doctoral Research Fellow, Department of Ocean and Resources Engineering, University of Hawaii Abstract Cabled ocean observatory that enables abundant powerEffort on Developing Cabled Ocean Observatories in China Yanhu Chen Research Assitant, Institute

Frandsen, Jannette B.

386

An Internal Coaxial Cable Electrical Connector For Use In Downhole Tools  

DOE Patents [OSTI]

A seal for a coaxial cable electrical connector more specifically an internal seal for a coaxial cable connector placed within a coaxial cable and its constituent components. A coaxial cable connector is in electrical communcation with an inductive transformer and a coaxial cable. The connector is in electrical communication with the outer housing of the inductive transformer. A generally coaxial center conductor, a portion of which could be the coil in the inductive transformer, passes through the connector, is electrically insulated from the connector, and is in electrical communication with the conductive core of the coaxial cable. The electrically insulating material also doubles as a seal to safegaurd against penetration of fluid, thus protecting against shorting out of the electrical connection. The seal is a multi-component seal, which is pre-compressed to a desired pressure rating. The coaxial cable and inductive transformer are disposed within downhole tools to transmit electrical signals between downhole tools within a drill string. The internal coaxial cable connector and its attendant seal can be used in a plurality of downhole tools, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David S. (Lehi, UT); Dahlgren, Scott (Provo, UT); Fox, Joe (Spanish Fork, UT); Sneddon, Cameron (Provo, UT); Briscoe, Michael (Lehi, UT)

2005-09-20T23:59:59.000Z

387

Valuable bridges : cable-stayed bridges and value engineering in American civil engineering culture, 1969-1979  

E-Print Network [OSTI]

A history and theory of cable-stayed bridges in the context of a cultural discourse on civil construction projects' value, this thesis studies the significance of cable-stayed bridge designs to 'value engineering' objectives ...

Samuels, Fallon M. (Fallon Michele)

2007-01-01T23:59:59.000Z

388

New MV cable design for wet environments in underground distribution systems  

SciTech Connect (OSTI)

This paper describes the development of new wet design MV power cables, up to 35 kV, using EPDM compound as insulation and longitudinal water tightness. The combination of the cable design and the type of insulation compound allow for reduction of the insulation thickness in such a way, as to have an electrical stress at the conductor of 4 kV/mm which is significantly greater than used in MV distribution cables. Following a methodology established, at the author's company, the reliability of this design, cable and EPDM's formulation, in wet location, without metallic water barriers, was well demonstrated. Mini-installation of model cables in service-like conditions, to estimate the ageing rate, are presented and discussed.

Teixeira, M.D.R. Jr. (Ficap Fios e Cabos Plasticos do Brasil SA, Rio De Janeiro (BR))

1990-04-01T23:59:59.000Z

389

CUDI A Model for Calculation of Electrodynamic and Thermal Behaviour of Superconducting Rutherford Cables  

E-Print Network [OSTI]

CUDI is the extended Fortran code to calculate the electrodynamic and thermal behaviour of any type of Rutherford cable subject to global and/or local variations in field, transport current, and external heat release. The internal parameters of the cable can be freely varied along the length and across the width, such as contact resistances, critical current, cooling rates etc. In this way, all the typical non-uniformities occurring in a cable, e.g. broken filaments, strand welds, cable joints, and edge degradation can be simulated. Also the characteristics of the strands in the cable can be varied from strand to strand. Heat flows through the matrix, through the interstrand contacts, and to the helium are incorporated, as well as the self-field and self- and mutual inductances between the strands. The main features and structure of the program will be discussed.

Verweij, A

2006-01-01T23:59:59.000Z

390

Performance Evaluation of K-DEMO Cable-in-conduit Conductors Using the Florida Electro-Mechanical Cable Model  

SciTech Connect (OSTI)

The United States ITER Project Office (USIPO) is responsible for design of the Toroidal Field (TF) insert coil, which will allow validation of the performance of significant lengths of the conductors to be used in the full scale TF coils in relevant conditions of field, current density and mechanical strain. The Japan Atomic Energy Agency (JAEA) will build the TF insert which will be tested at the Central Solenoid Model Coil (CSMC) Test facility at JAEA, Naka, Japan. Three dimensional mathematical model of TF Insert was created based on the initial design geometry data, and included the following features: orthotropic material properties of superconductor material and insulation; external magnetic field from CSMC, temperature dependent properties of the materials; pre-compression and plastic deformation in lap joint. Major geometrical characteristics of the design were preserved including cable jacket and insulation shape, mandrel outline, and support clamps and spacers. The model is capable of performing coupled structural, thermal, and electromagnetic analysis using ANSYS. Numerical simulations were performed for room temperature conditions; cool down to 4K, and the operating regime with 68kA current at 11.8 Tesla background field. Numerical simulations led to the final design of the coil producing the required strain levels on the cable, while simultaneously satisfying the ITER magnet structural design criteria.

Zhai, Yuhu

2013-07-16T23:59:59.000Z

391

Abstract--Recent studies of long EHV cables show the importance of performing temporary overvoltage analyses. As the  

E-Print Network [OSTI]

health. Because of this shift in trend, the recently proposed HVAC underground cable systems are longer lines. HVAC underground cable systems are used, but their use has mainly been limited to densely populated areas. As such, HVAC underground cable systems have until now been limited both in terms of length

Bak, Claus Leth

392

The University of Texas at Austin September 30, 2011 Cable Trays for Communications Systems 27 05 36-1  

E-Print Network [OSTI]

Cable Tray Installation Guidelines 4. NFPA 70B, Recommended Practice for Electrical Equipment manufacturer that the cable tray system has been UL-tested to be continuously grounded. c) Where the desiredThe University of Texas at Austin September 30, 2011 Cable Trays for Communications Systems 27 05

Dawson, Clint N.

393

Dynamic Voltage Regulation Using Distributed Energy Resources  

SciTech Connect (OSTI)

Many distributed energy resources (DE) are near load centres and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide ancillary services such as voltage regulation, nonactive power compensation, and power factor correction. A synchronous condenser and a microturbine with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Voltage control schemes of the inverter and the synchronous condenser are developed. The experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously, while the dynamic response of the inverter is faster than the synchronous condenser; and that integrated voltage regulation (multiple DE perform voltage regulation) can increase the voltage regulation capability, increase the lifetime of the equipment, and reduce the capital and operation costs.

Xu, Yan [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Kueck, John D [ORNL

2007-01-01T23:59:59.000Z

394

Surface and Structural Stabilities of Carbon Additives in High...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Structural Stabilities of Carbon Additives in High Voltage Lithium Ion Batteries. Surface and Structural Stabilities of Carbon Additives in High Voltage Lithium Ion Batteries....

395

Voltage Vehicles | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ < RAPID Jump to:Seadov PtyInformationSEDS data Jump to: navigation, search ToolVoith HydroVoltage

396

Compact multiwavelength transmitter module for multimode fiber optic ribbon cable  

DOE Patents [OSTI]

A compact multiwavelength transmitter module for multimode fiber optic ribbon cable, which couples light from an M.times.N array of emitters onto N fibers, where the M wavelength may be distributed across two or more vertical-cavity surface-emitting laser (VCSEL) chips, and combining emitters and multiplexer into a compact package that is compatible with placement on a printed circuit board. A key feature is bringing together two emitter arrays fabricated on different substrates--each array designed for a different wavelength--into close physical proximity. Another key feature is to compactly and efficiently combine the light from two or more clusters of optical emitters, each in a different wavelength band, into a fiber ribbon.

Deri, Robert J. (Pleasanton, CA); Pocha, Michael D. (Livermore, CA); Larson, Michael C. (Goleta, CA); Garrett, Henry E. (Livermore, CA)

2002-01-01T23:59:59.000Z

397

Light weight underground pipe or cable installing device  

SciTech Connect (OSTI)

This invention pertains to a light weight underground pipe or cable installing device adapted for use in a narrow and deep operating trench. More particularly this underground pipe installing device employs a pair of laterally movable gates positioned adjacent the bottom of the operating trench where the earth is more solid to securely clamp the device in the operating trench to enable it to withstand the forces exerted as the actuating rod is forced through the earth from the so-called operating trench to the target trench. To accommodate the laterally movable gates positioned adjacent the bottom of the narrow pipe installing device, a pair of top operated double-acting rod clamping jaws, operated by a hydraulic cylinder positioned above the actuating rod are employed.

Schosek, W. O.

1985-01-08T23:59:59.000Z

398

Analysis of nonconcurrent cable moorings with rigid and elastic inclusions  

E-Print Network [OSTI]

pointsQ2andQ3are 2 X2i + Y2S + 2k (e) r3 = X31 + Y3J + 23k The external forces at the attachment points are as previously defined and are given by l = Fxli + Fy]1 F2 = Fx2i + Fy2~ F3 = Rx3i + Fy3$ + Fzlk + FZ2k + Fz3k (8) The cable reactions... C1X2 + C612 - C3 3 6 3 0 (20) CZX2 - CSY2 + C4X3 - C6Y3 = 0 The coefficients Cl - C6 in the above equations are defined as Cl = Fz2 + Rz2 C3 Fz3 + Rz3 4 = Fy3 ' Ry3 C6 = Fx2 + Rx 2 C6 = Fx3 + RX3 Solution of Nonlinear Simultaneous E uations...

Greer, Geral Glen

2012-06-07T23:59:59.000Z

399

The Matrix Converter Drive Performance Under Abnormal Input Voltage Conditions  

E-Print Network [OSTI]

that generates variable magnitude variable frequency output voltage from the ac utility line. It has high power conversion device, the disturbances at the ac utility grid (line) side are immediately reflected to the load and large capacitor associated with it, there is no stored energy in the MC. As a result, the utility line

Hava, Ahmet

400

Experimental characterization of faults on low-voltage systems  

E-Print Network [OSTI]

arcing ground faults '10'. The first scheme is very similar to the Ground Sensor Protection scheme described in i8j. The second scheme employs the fact that the voltage waveshape at the 1'suit point is flat topped. Harmonic analysis shows that... value when an arcing fault takes place. Continued presence of a, relatively high third- harmonic component in the bus voltage is a definite sign that there is an arcing fault in the system, Kusko and Peeran recommended the use of a, third harmonic...

Ahmed, Jubayer

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Long-term aging and loss-of-coolant accident (LOCA) testing of electrical cables  

SciTech Connect (OSTI)

Experiments were performed to assess the aging degradation and loss-of-coolant accident (LOCA) behavior of electrical cables subjected to long-term aging exposures. Four different cable types were tested in both the U.S. and France: (1) U.S. 2 conductor with ethylene propylene rubber (EPR) insulation and a Hypalon jacket. (2) U.S. 3 conductor with cross-linked polyethylene (XLPE) insulation and a Hypalon jacket. (3) French 3 conductor with EPR insulation and a Hypalon jacket. (4) French coaxial with polyethylene (PE) insulation and a PE jacket. The data represent up to 5 years of simultaneous aging where the cables were exposed to identical aging radiation doses at either 40{degrees}C or 70{degrees}C; however, the dose rate used for the aging irradiation was varied over a wide range (2-100 Gy/hr). Aging was followed by exposure to simulated French LOCA conditions. Several mechanical, electrical, and physical-chemical condition monitoring techniques were used to investigate the degradation behavior of the cables. All the cables, except for the French PE cable, performed acceptably during the aging and LOCA simulations. In general, cable degradation at a given dose was highest for the lowest dose rate, and the amount of degradation decreased as the dose rate was increased.

Nelson, C.F.; Gauthier, G.; Carlin, F. [and others

1996-10-01T23:59:59.000Z

402

Chapter 17. High-Voltage Systems and Dielectric Materials High-Voltage Systems and Dielectric Materials  

E-Print Network [OSTI]

aromatic, naphthenic, and paraffinic molecules with complex molecular structures. With the advancement

403

Voltage controlled MESFET pulse shape generator  

SciTech Connect (OSTI)

A programmable pulse shape generator capable of producing pulse shapes for Nova and Beamlet has been designed and simulated using the circuit code SPICE. The design utilizes power MESFETS, which are commonly used in microwave amplifiers. The pulse shape is varied by setting a bias voltage on each in a chain of MESFETS with a 200 ps temporal resolution. The electrical pulse then drives an integrated electro-optic modulator similar to what is on Beamlet. Pulse shapes 22 and 25, used on Nova, have been generated by this design. There is no fundamental barrier to making such a pulse generator for use on the National Ignition Facility. In fact, the longer time scales on the NIF pulse will ease the high speed requirements of the pulse shape generator allowing the use of less expensive components. The next step will be to build a prototype circuit for initial testing on Beamlet and Nova.

Burkhart, S.C.

1994-10-26T23:59:59.000Z

404

Supply Voltage Degradation Aware Analytical Placement Andrew B. Kahng Bao Liu Qinke Wang  

E-Print Network [OSTI]

% performance degradation, and the effect is super-linear [22]. Therefore, power/ground Work partially supported along a supply cur- rent path, and (2) adding large decoupling capacitors close to supply voltage supply voltage drop). For high frequency de- signs, a number of decoupling capacitors need to be added

Liu, Bao

405

LM193/LM293/LM393/LM2903 Low Power Low Offset Voltage Dual Comparators  

E-Print Network [OSTI]

LM193/LM293/LM393/LM2903 Low Power Low Offset Voltage Dual Comparators General Description The LM clock timers; multivibrators and high voltage digital logic gates. The LM193 series was designed to directly interface with TTL and CMOS. When operated from both plus and minus power supplies, the LM193

Lanterman, Aaron

406

VOLTAGE COLLAPSE AND TRANSIENT ENERGY FUNCTION ANALYSES OF AC/DC SYSTEMS  

E-Print Network [OSTI]

for power system dynamic models, including a third order representation of high voltage direct current (HVDC power limits, HVDC firing angle limits and voltage dependent current order limits (VDCOL) are shown the derivation of individual component Lyapunov functions for simplified models of HVDC links connected

Cañizares, Claudio A.

407

Log of a young author's thinking: George W. Cable's "Drop Shot".  

E-Print Network [OSTI]

. . t 1974 Major Subject: English LOG OF A YOUNG AUTHOR'S THINKING: GEORGE W CABLE'S "DROP SHOT" A Thesis by AUTRY JAMES SINITIERE Approved as to style and content by: Chairman of Committe Hea of Department M er ember) August 1974 & s ~~. )$, gg... APSTRACT Log of a Young Author's Thinking: George W. Cable's "Drop Shot" (August 1974) Autry James Sinitiere, B. A. , College of Santa Fe Chairman of Advisory Committee: Dr Richard H. Ballinger In February 1870 George W. Cable began writing a * p p...

Sinitiere, Autry James

1974-01-01T23:59:59.000Z

408

Wind Power Plant Voltage Stability Evaluation: Preprint  

SciTech Connect (OSTI)

Voltage stability refers to the ability of a power system to maintain steady voltages at all buses in the system after being subjected to a disturbance from a given initial operating condition. Voltage stability depends on a power system's ability to maintain and/or restore equilibrium between load demand and supply. Instability that may result occurs in the form of a progressive fall or rise of voltages of some buses. Possible outcomes of voltage instability are the loss of load in an area or tripped transmission lines and other elements by their protective systems, which may lead to cascading outages. The loss of synchronism of some generators may result from these outages or from operating conditions that violate a synchronous generator's field current limit, or in the case of variable speed wind turbine generator, the current limits of power switches. This paper investigates the impact of wind power plants on power system voltage stability by using synchrophasor measurements.

Muljadi, E.; Zhang, Y. C.

2014-09-01T23:59:59.000Z

409

A Cabled Acoustic Telemetry System for Detecting and Tracking Juvenile Salmon: Part 2. Three-Dimensional Tracking and Passage Outcomes  

SciTech Connect (OSTI)

In Part 1 of this paper [1], we presented the engineering design and instrumentation of the Juvenile Salmon Acoustic Telemetry System (JSATS) cabled system, a nonproprietary technology developed by the U.S. Army Corps of Engineers, Portland District, to meet the needs for monitoring the survival of juvenile salmonids through the 31 dams in the Federal Columbia River Power System. Here in Part 2, we describe how the JSATS cabled system was employed as a reference sensor network for detecting and tracking juvenile salmon. Time-of-arrival data for valid detections on four hydrophones were used to solve for the three-dimensional (3D) position of fish surgically implanted with JSATS acoustic transmitters. Validation tests demonstrated high accuracy of 3D tracking up to 100 m from the John Day Dam spillway. The along-dam component, used for assigning the route of fish passage, had the highest accuracy; the median errors ranged from 0.06 to 0.22 m, and root mean square errors ranged from 0.05 to 0.56 m at distances up to 100 m. For the case study at John Day Dam during 2008, the range for 3D tracking was more than 100 m upstream of the dam face where hydrophones were deployed, and detection and tracking probabilities of fish tagged with JSATS acoustic transmitters were higher than 98%. JSATS cabled systems have been successfully deployed on several major dams to acquire information for salmon protection and for development of more “fish-friendly” hydroelectric facilities.

Deng, Zhiqun; Weiland, Mark A.; Fu, Tao; Seim, Thomas A.; Lamarche, Brian L.; Choi, Eric Y.; Carlson, Thomas J.; Eppard, Matthew B.

2011-05-26T23:59:59.000Z

410

SEMIACTIVE DAMPING OF CABLES WITH SAG E.A. Johnson,1 R.E. Christenson,2 and B.F. Spencer, Jr.2  

E-Print Network [OSTI]

- cantly superior supplemental damping. This paper extends the previous work by adding sag, inclination damping, cable galloping, rain-wind induced vibration, cable-stayed bridges, structural control bridges and other cable structures. These cables are subject to environmental excitations, such as rain-wind

Johnson, Erik A.

411

Group 3: Humidity, Temperature, and Voltage (Presentation)  

SciTech Connect (OSTI)

Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

Wohlgemuth, J.

2013-05-01T23:59:59.000Z

412

Nexans & Pirelli Awarded Major Energy Sector Contract  

E-Print Network [OSTI]

km (56 miles) of new high-voltage cables. The contract calls for the manufacture and laying of three. Pirelli will manufacture and install two submarine power cables and one telecommunications cable. These cables will be manufactured at Pirelli's Arco Felice (Naples), Italy plant. The Pirelli share

Kavehrad, Mohsen

413

High Temperature, High Voltage Fully Integrated Gate Driver Circuit  

Broader source: Energy.gov (indexed) [DOE]

temperature gate drive is being developed for use with future wide band gap (silicon carbide and gallium nitride) switching devices. * Universal drive that is capable of driving...

414

Easily disassembled electrical connector for high voltage, high frequency connections  

DOE Patents [OSTI]

An easily accessible electrical connector capable of rapid assembly and disassembly is described wherein a wide metal conductor sheet may be evenly contacted over the entire width of the conductor sheet by opposing surfaces on the connector which provide an even clamping pressure against opposite surfaces of the metal conductor sheet using a single threaded actuating screw. 13 figures.

Milner, J.R.

1994-05-10T23:59:59.000Z

415

Dielectrometry measurements of moisture diffusion and temperature dynamics in oil impregnated paper insulated electric power cables  

E-Print Network [OSTI]

Paper insulated lead covered (PILC) cables have played an important role in underground power distribution for a hundred years. Replacing aged PILC before failure is critical to managing power distribution. Three prominent ...

Thomas, Zachary M. (Zachary Michael)

2007-01-01T23:59:59.000Z

416

Control signal transmission through power supply cables of a 3-phase PWM motor  

E-Print Network [OSTI]

Modem process control systems often employ accurate position or speed controlled PWM motors, which require feedback data for the drive control loop. Current methods require an independently shielded cable for feedback data ...

Mendez, Jose A. (Jose Antonio Mendez Alcazar)

2006-01-01T23:59:59.000Z

417

Design and performance relationships for cable distribution in multi-story office buildings  

E-Print Network [OSTI]

Weaknesses associated with cable distribution systems suggest a lack of design consideration in the planning stage of a building. The primary question to be addressed in this study is do relationships between design considerations and building...

Ryan, Richard Cecil

1990-01-01T23:59:59.000Z

418

A Test of HTS Power Cable in a Sweeping Magnetic Field  

SciTech Connect (OSTI)

Short sample HTS power cable composed of multiple 344C-2G strands and designed to energize a fast-cycling dipole magnet was exposed to a sweeping magnetic field in the (2-20) T/s ramping rate. The B-field orientation toward the HTS strands wide surface was varied from 0{sup 0} to 10{sup 0}, in steps of 1{sup 0}. The test arrangement allowed measurement of the combined hysteresis and eddy current power losses. For the validity of these measurements, the power losses of a short sample cable composed of multiple LTS wire strands were also performed to compare with the known data. The test arrangement of the power cable is described, and the test results are compared with the projections for the eddy and hysteresis power losses using the fine details of the test cable structures.

Piekarz, H.; Hays, S.; Blowers, J.; Shiltsev, V.; /Fermilab

2011-11-29T23:59:59.000Z

419

Capturing power at higher voltages from arrays of microbial fuel cells without voltage reversal  

E-Print Network [OSTI]

is too low to be used directly for many practical applications. For example, a single light emitting diode (LED) requires a minimum voltage of 2 V.2 Thus, effective methods of boosting MFC voltages

420

The Constant Voltage Transformer (CVT) for Mitigating Effects of Voltage Sags on Industrial Equipment  

E-Print Network [OSTI]

) an increase in loads that use power electronics in some type of power conversion configuration [1][2]. This paper presents applications of the constant-voltage transformer (CVT) for mitigating the effects of electric service voltage sags on industrial...

Ferraro, R. J.; Osborne, R.; Stephens, R.

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Literature review of environmental qualification of safety-related electric cables: Literature analysis and appendices. Volume 2  

SciTech Connect (OSTI)

In support of the US NRC Environmental Qualification (EQ) Research Program, a literature review was performed to identify past relevant work that could be used to help fully or partially resolve issues of interest related to the qualification of low-voltage electric cable. A summary of the literature reviewed is documented in Volume 1 of this report. In this, Volume 2 of the report, dossiers are presented which document the issues selected for investigation in this program, along with recommendations for future work to resolve the issues, when necessary. The dossiers are based on an analysis of the literature reviewed, as well as expert opinions. This analysis includes a critical review of the information available from past and ongoing work in thirteen specific areas related to EQ. The analysis for each area focuses on one or more questions which must be answered to consider a particular issue resolved. Results of the analysis are presented, along with recommendations for future work. The analysis is documented in the form of a dossier for each of the areas analyzed.

Lofaro, R.; Bowerman, B.; Carbonaro, J. [Brookhaven National Lab., Upton, NY (United States)] [and others

1996-04-01T23:59:59.000Z

422

K.K. Gan IWORID-8 1 Bandwidths of Micro Twisted-Pair Cables  

E-Print Network [OSTI]

-V Characteristics very good optical power candidate for irradiation study Optowell TP85-LCP0N 0.0 0.5 1.0 1.5 2K.K. Gan IWORID-8 1 Bandwidths of Micro Twisted-Pair Cables and Fusion Spliced SIMM-GRIN Fibers Bandwidth of micro twisted-pair cables Bandwidth of fusion spliced SIMM-GRIN fibers Measurement of VCSEL

Gan, K. K.

423

Voltage Collapse SimulationVoltage Collapse Simulation (Eastern Interconnection(Eastern Interconnection  

E-Print Network [OSTI]

PSERC Voltage Collapse SimulationVoltage Collapse Simulation (Eastern Interconnection(Eastern Interconnection Scenario)Scenario) Simulation Prepared by Dennis J. RaySimulation Prepared by Dennis J. Ray Interconnection based on a series of generator and line outages. An actual voltage collapse may not occur due

424

DESIGN AND IMPLEMENTATION OF A FUZZY LOGIC-BASED VOLTAGE CONTROLLER FOR VOLTAGE REGULATION  

E-Print Network [OSTI]

1 DESIGN AND IMPLEMENTATION OF A FUZZY LOGIC-BASED VOLTAGE CONTROLLER FOR VOLTAGE REGULATION In this paper the design and implementation of a fuzzy logic-based controller is described for regulating the output voltage of a synchronous generator. An automated fuzzy logic-based control strategy is presented

LaMeres, Brock J.

425

Optimal Power Flow Incorporating Voltage Collapse Constraints  

E-Print Network [OSTI]

Optimal Power Flow Incorporating Voltage Collapse Constraints William Rosehart Claudio Ca on the current operating con- ditions is presented. Second, an Optimal Power Flow formulation that incorporates: Voltage Collapse, Optimal Power Flow, Bifur- cations. I. Introduction As open-access market principles

Cañizares, Claudio A.

426

Voltage regulation in linear induction accelerators  

DOE Patents [OSTI]

Improvement in voltage regulation in a Linear Induction Accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance.

Parsons, William M. (Santa Fe, NM)

1992-01-01T23:59:59.000Z

427

Voltage regulation in linear induction accelerators  

DOE Patents [OSTI]

Improvement in voltage regulation in a linear induction accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core is disclosed. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance. 4 figs.

Parsons, W.M.

1992-12-29T23:59:59.000Z

428

Non-contact current and voltage sensor  

SciTech Connect (OSTI)

A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

Carpenter, Gary D; El-Essawy, Wael; Ferreira, Alexandre Peixoto; Keller, Thomas Walter; Rubio, Juan C; Schappert, Michael A

2014-03-25T23:59:59.000Z

429

Flexible method for monitoring fuel cell voltage  

DOE Patents [OSTI]

A method for equalizing the measured voltage of each cluster in a fuel cell stack wherein at least one of the clusters has a different number of cells than the identical number of cells in the remaining clusters by creating a pseudo voltage for the different cell numbered cluster. The average cell voltage of the all of the cells in the fuel cell stack is calculated and multiplied by a constant equal to the difference in the number of cells in the identical cell clusters and the number of cells in the different numbered cell cluster. The resultant product is added to the actual voltage measured across the different numbered cell cluster to create a pseudo voltage which is equivalent in cell number to the number of cells in the other identical numbered cell clusters.

Mowery, Kenneth D. (Noblesville, IN); Ripley, Eugene V. (Russiaville, IN)

2002-01-01T23:59:59.000Z

430

Wide-range voltage modulation  

SciTech Connect (OSTI)

The Superconducting Super Collider`s Medium Energy Booster Abort (MEBA) kicker modulator will supply a current pulse to the abort magnets which deflect the proton beam from the MEB ring into a designated beam stop. The abort kicker will be used extensively during testing of the Low Energy Booster (LEB) and the MEB rings. When the Collider is in full operation, the MEBA kicker modulator will abort the MEB beam in the event of a malfunction during the filling process. The modulator must generate a 14-{mu}s wide pulse with a rise time of less than 1 {mu}s, including the delay and jitter times. It must also be able to deliver a current pulse to the magnet proportional to the beam energy at any time during ramp-up of the accelerator. Tracking the beam energy, which increases from 12 GeV at injection to 200 GeV at extraction, requires the modulator to operate over a wide range of voltages (4 kV to 80 kV). A vacuum spark gap and a thyratron have been chosen for test and evaluation as candidate switches for the abort modulator. Modulator design, switching time delay, jitter and pre-fire data are presented.

Rust, K.R.; Wilson, J.M.

1992-06-01T23:59:59.000Z

431

PH-315 A. La Rosa VOLTAGE-CONTROLLED OSCILLATOR  

E-Print Network [OSTI]

PH-315 A. La Rosa VOLTAGE-CONTROLLED OSCILLATOR 1. PURPOSE: An integrator and a Schmitt Trigger voltage; hence its name "voltage-controlled oscillator." 2. VOLTAGE-CONTROLLED OSCILLATOR Figure 1 shows voltage. An unusual feature of the circuit is its operation using a single positive supply.1 #12;- + 50k V

432

A SCR SWITCHED CAPACITOR VOLTAGE REGULATOR FOR 150 kV NEUTRAL BEAM POWER SUPPLY  

E-Print Network [OSTI]

et a1. , "150-kV, 80-A Solid State Power Supply for Neutral100% solid state and provides 1% regulation at power levelssolid state high voltage re- gulator. The block diagram of the power

Milnes, K.A.

2011-01-01T23:59:59.000Z

433

To connect to Boiler Television, you will need to provide a coaxial cable to connect your television set to the cable wall outlet. In connecting the coaxial  

E-Print Network [OSTI]

To connect to Boiler Television, you will need to provide a coaxial cable to connect your? By providing this initial information, you help Boiler Television staff assess and resolve this issue as soon for use with any University Residences work request -- not just for the Boiler Television system. Set

Ginzel, Matthew

434

Final Report [The c-Abl signaling network in the radioadaptive response  

SciTech Connect (OSTI)

The radioadaptive response, or radiation hormesis, i.e. a low dose of radiation can protect cells and organisms from the effects of a subsequent higher dose, is a widely recognized phenomenon. Mechanisms underlying such radiation hormesis, however, remain largely unclear. Preliminary studies indicate an important role of c-Abl signaling in mediating the radioadaptive response. We propose to investigate how c-Abl regulates the crosstalk between p53 and NF?B in response to low doses irradiation. We found in our recent study that low dose IR induces a reciprocal p53 suppression and NF?B activation, which induces HIF-a and subsequently a metabolic reprogramming resulting in a transition from oxidative phosphorylation to glycolysis. Of importance is that this glycolytic switch is essential for the radioadaptive response. This low-dose radiationinduced HIF1? activation was in sharp contrast with the high-dose IR-induced p53 activation and HIF1? inhibition. HIF1? and p53 seem to play distinct roles in mediating the radiation dose-dependent metabolic response. The induction of HIF1?-mediated glycolysis is restricted to a low dose range of radiation, which may have important implications in assessing the level of radiation exposure and its potential health risk. Our results support a dose-dependent metabolic response to IR. When IR doses are below the threshold of causing detectable DNA damage (<0.2Gy) and thus little p53 activation, HIF1? is induced resulting in induction of glycolysis and increased radiation resistance. When the radiation dose reaches levels eliciting DNA damage, p53 is activated and diminishes the activity of HIF1? and glycolysis, leading to the induction of cell death. Our work challenges the LNT model of radiation exposure risk and provides a metabolic mechanism of radioadaptive response. The study supports a need for determining the p53 and HIF1? activity as a potential reliable biological readout of radiation exposure in humans. The exquisite sensitivity of cellular metabolism to low doses of radiation could also serve as a valuable biomarker for estimating the health effects of low-level radiation exposure.

Chi-Min, Yuan

2014-01-28T23:59:59.000Z

435

UWB radar technique for arc detection in coaxial cables and waveguides  

SciTech Connect (OSTI)

As spread spectrum technology has revolutionized the communications industry, Ultra Wide Band (UWB) technology is dramatically improving radar performances. These advanced signal processing techniques have been adapted to coaxial cables and waveguides to provide new features and enhanced performance on arc detection. UWB signals constituted by a sequence of chips (properly chosen to reduce side lobes and to improve detection accuracy) are transmitted along the transmission lines at a specified Pulse Repetition Frequency (PRF) and their echoes are received by means of directional couplers. The core of the receiver is an ultra high-speed correlator implemented in a Digital Signal Processor (DSP). When a target (arc) is detected, its position and its 'radar cross section' are calculated to be able to provide the arc position along the transmission line and to be able to classify the type of detected arc. The 'background scattering' is routinely extracted from the received signal at any pulse. This permits to be resilient to the background structure of transmission lines (bends, junctions, windows, etc.). Thanks to the localization feature, segmentation is also possible for creating sensed and non-sensed zones (for example, to be insensitive to antenna load variations)

Maggiora, R.; Salvador, S. [Politecnico di Torino, Department of Electronics, Torino (Italy)

2009-11-26T23:59:59.000Z

436

Literature review of environmental qualification of safety-related electric cables: Summary of past work. Volume 1  

SciTech Connect (OSTI)

This report summarizes the findings from a review of published documents dealing with research on the environmental qualification of safety-related electric cables used in nuclear power plants. Simulations of accelerated aging and accident conditions are important considerations in qualifying the cables. Significant research in these two areas has been performed in the US and abroad. The results from studies in France, Germany, and Japan are described in this report. In recent years, the development of methods to monitor the condition of cables has received special attention. Tests involving chemical and physical examination of cable`s insulation and jacket materials, and electrical measurements of the insulation properties of cables are discussed. Although there have been significant advances in many areas, there is no single method which can provide the necessary information about the condition of a cable currently in service. However, it is possible that further research may identify a combination of several methods that can adequately characterize the cable`s condition.

Subudhi, M. [Brookhaven National Lab., Upton, NY (United States)

1996-04-01T23:59:59.000Z

437

Device to facilitate moving an electrical cable of an electric vehicle charging station and method of providing the same  

DOE Patents [OSTI]

Some embodiments include a device to facilitate moving an electrical cable of an electric vehicle charging station. Other embodiments of related systems and methods are also disclosed.

Karner, Donald B

2014-04-29T23:59:59.000Z

438

Voltage Management of Networks with Distributed Generation.   

E-Print Network [OSTI]

At present there is much debate about the impacts and benefits of increasing the amount of generation connected to the low voltage areas of the electricity distribution network. The UK government is under political ...

O'Donnell, James

2008-01-01T23:59:59.000Z

439

Bonfire-safe low-voltage detonator  

DOE Patents [OSTI]

A column of explosive in a low-voltage detonator which makes it bonfire-safe includes a first layer of an explosive charge of CP, or a primary explosive, and a second layer of a secondary organic explosive charge, such as PETN, which has a degradation temperature lower than the autoignition temperature of the CP or primary explosives. The first layer is composed of a pair of increments disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to and in contact with an electrical ignition device at one end of the bore. The second layer is composed of a plurality of increments disposed in the housing bore in a transition region of the explosive column next to and in contact with the first layer on a side opposite from the ignition device. The first layer is loaded under a sufficient high pressure, 25 to 40 kpsi, to achieve ignition, whereas the second layer is loaded under a sufficient low pressure, about 10 kpsi, to allow occurrence of DDT. Each increment of the first and second layers has an axial length-to-diameter ratio of one-half.

Lieberman, Morton L. (Albuquerque, NM)

1990-01-01T23:59:59.000Z

440

Bonfire-safe low-voltage detonator  

DOE Patents [OSTI]

A column of explosive in a low-voltage detonator which makes it bonfire-safe includes a first layer of an explosive charge of CP, or a primary explosive, and a second layer of a secondary organic explosive charge, such as PETN, which has a degradation temperature lower than the autoignition temperature of the CP or primary explosives. The first layer is composed of a pair of increments disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to and in contact with an electrical ignition device at one end of the bore. The second layer is composed of a plurality of increments disposed in the housing bore in a transition region of the explosive column next to and in contact with the first layer on a side opposite from the ignition device. The first layer is loaded under a sufficient high pressure, 25 to 40 kpsi, to achieve ignition, whereas the second layer is loaded under a sufficient low pressure, about 10 kpsi, to allow occurrence of DDT. Each increment of the first and second layers has an axial length-to-diameter ratio of one-half. 2 figs.

Lieberman, M.L.

1988-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Group 3: Humidity, Temperature, and Voltage  

Broader source: Energy.gov [DOE]

This PowerPoint presentation, focused on humidity, temperature and voltage testing, was originally presented by John Wohlgemuth at the NREL 2013 PV Module Reliability Workshop on Feb. 26-27, 2013 in Denver, CO. It summarizes the activities of a working group chartered to develop accelerated stress tests that can be used as comparative predictors of module life versus stresses associated with humidity, temperature and voltage.

442

Addressing the Voltage Fade Issue with Lithium-Manganese-Rich...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials 2013 DOE...

443

Addressing the Voltage Fade Issue with Lithium-Manganese-Rich...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials 2012 DOE Hydrogen and...

444

Development of bending characteristics for the TPX TF magnet coil cable-in-conduit conductor  

SciTech Connect (OSTI)

The conductor for the toroidal field (TF) magnet coils for the Tokamak Physics experiment (TPX) is an assembly of stranded Nb{sub 3}Sn superconductor sheathed by an Incoloy 908 conduit. The coil shape, when coupled with stiffness of the cable-in-conduit conductor (CICC) is such that conventional magnet winding techniques cannot be utilized. Therefore a bending and forming method will be employed in the TF coils. The cable will be reacted after bending because the reaction process hardens the conduit and also lowers the strain the cable can withstand without performance degradation. The Incoloy 908 conduit also work hardens quickly, necessitating the production of the required coil shape in one step without correction. This paper discusses the limiting processes for forming the TPX TF magnet geometry, the methods utilized in establishing the CICC bending characteristics and the methods employed to account for material springback so that a coil can be manufactured accurately and efficiently.

Grut, K.E.; Holbrook, R.L.; Hook, E.; Antaya, T.A. [Babcock and Wilcox, Lynchburg, VA (United States)

1996-12-31T23:59:59.000Z

445

An investigation into the properties and characteristics of homogeneous tapered cables  

E-Print Network [OSTI]

in detail in this paper leading to configurations which have been labeled E-tapered and Constant Stress Catenary. While these are optimized for their specific applications, they are not necessarily the best for devia- tions from design conditions... or to reduce to a ratio ys T "- A = ea T A 0 0 (8) Eqs. 5 and 8 constitute the descriptive equations for what Nowatzki called a "perfectly tapered cable". Herein, this will be referred to as an E-tapered cable. In Fig. 7, Eq. 9 is plotted using a unit...

deCastongrene, Russell Othomar

1975-01-01T23:59:59.000Z

446

The University of Texas at Austin September 30, 2011 Communications Optical Fiber Backbone Cabling 27 13 23-1  

E-Print Network [OSTI]

, as required by law: 1. National Electric Code (NEC) 2. ANSI/IEEE C2 ­ National Electrical Safety Code C. ANSI/TIA-568-C.0, Generic Telecommunications Cabling for Customer Premises 3. ANSI/TIA-568-C.3, Optical Fiber Cabling Components Standard. 4. ANSI/TIA/EIA-604-10A, FOCIS 10, Fiber Optic Connector

Dawson, Clint N.

447

LM231A/LM231/LM331A/LM331 Precision Voltage-to-Frequency Converters  

E-Print Network [OSTI]

LM231A/LM231/LM331A/LM331 Precision Voltage-to-Frequency Converters General Description The LM231/LM331 family of voltage-to-frequency converters are ideally suited for use in simple low, the LM231A/LM331A attain a new high level of accuracy versus temperature which could only be at- tained

Lanterman, Aaron

448

Electronic circuit for measuring series connected electrochemical cell voltages  

DOE Patents [OSTI]

An electronic circuit for measuring voltage signals in an energy storage device is disclosed. The electronic circuit includes a plurality of energy storage cells forming the energy storage device. A voltage divider circuit is connected to at least one of the energy storage cells. A current regulating circuit is provided for regulating the current through the voltage divider circuit. A voltage measurement node is associated with the voltage divider circuit for producing a voltage signal which is proportional to the voltage across the energy storage cell.

Ashtiani, Cyrus N. (West Bloomfield, MI); Stuart, Thomas A. (Toledo, OH)

2000-01-01T23:59:59.000Z

449

National High Magnetic Field Laboratory - Magnets and Materials...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Loss Measurements of a Cable-in-Conduit Conductor with Nb3Sn Strands for the High Field Section of the Series-Connected Hybrid Outsert Coil, IEEE Trans. Appl. Supercond., 19 (3,...

450

SiGe BiCMOS Topologies for Low-Voltage Millimeter-Wave Voltage Controlled Oscillators and Frequency Dividers  

E-Print Network [OSTI]

SiGe BiCMOS Topologies for Low-Voltage Millimeter-Wave Voltage Controlled Oscillators and Frequency-mail: tod@eecg.toronto.edu Abstract -- BiCMOS topologies for mm-wave voltage- controlled oscillators operation for mm-wave applications. II. BICMOS VOLTAGE-CONTROLLED OSCILLATOR The Colpitts topology

Voinigescu, Sorin Petre

451

Physical simulation study of dynamic voltage instability  

SciTech Connect (OSTI)

This paper presents a physical simulation of the dynamic behavior of voltage instability in an interconnected multimachine environment. The dynamic evolving process leading to eventual voltage collapse, the scenario of the progressive reactive support reduction resulting from the MXL protection relays, the OLTC operation, and the effect of switched-in capacitor banks are examined using physical facilities in the laboratory. The physical simulation results are also compared with digital simulation results. This physical investigation provides a reliable foundation for the effective development of assessment approaches and countermeasures.

Tso, S.K.; Zhu, T.X. [Univ. of Hong Kong (Hong Kong); Zeng, Q.Y. [Electric Power Research Inst., Beijing (China); Lo, K.L. [Univ. of Strathclyde, Glasgow (United Kingdom). Dept. of Electrical and Electrical Engineering

1995-12-31T23:59:59.000Z

452

State of the art analysis of online fault location on AC cables in underground transmission systems  

E-Print Network [OSTI]

on transmission level fault location methods have been focused on overhead lines. Because of the very different- termine the fault location. Because only one end meas- urements are used, the algorithm is derived usingState of the art analysis of online fault location on AC cables in underground transmission systems

Bak, Claus Leth

453

An Energy-Efficient Communication Scheme in Wireless Cable Sensor Networks  

E-Print Network [OSTI]

An Energy-Efficient Communication Scheme in Wireless Cable Sensor Networks Xiao Chen Department of Computer Science U. S. Naval Postgraduate School Monterey, CA 93943 ncrowe@nps.edu Abstract and communication. Like wireless sensor networks with point sensors, energy-efficient communication is still

Rowe, Neil C.

454

Engineering in the service of science; construction of a cabled ocean observatory  

E-Print Network [OSTI]

Engineering in the service of science; construction of a cabled ocean observatory Mr. Peter Phibbs for maintenance can quickly make a system uneconomic. Peter Phibbs was project manager for the $75M construction ocean observatory, and went into operation fifteen months ago. The infrastructure demonstrates not only

Frandsen, Jannette B.

455

K.K. Gan ATLAS Tracker Ungrade Workshop 1 Bandwidths of Micro Twisted-Pair Cables  

E-Print Network [OSTI]

/fall time after irradiation? What is optical power after irradiation? What current is needed for annealing Spliced SIMM-GRIN Fibers and Radiation Hardness of PIN/VCSEL Dec 8, 2006 W. Fernando, K.K. Gan, A. Law, H Bandwidth of micro twisted-pair cables Bandwidth of fusion spliced SIMM-GRIN fibers Radiation hardness

Gan, K. K.

456

Analysis Framework for Cooperating Mobile Cable Robots Xiaobo Zhou, Chin Pei Tang and Venkat Krovi  

E-Print Network [OSTI]

of Mechanical and Aerospace Engineering, State University of New York at Buffalo, Buffalo, NY 14260 USA xzhou9 energy consumption, ease of assembly/disassembly and reconfiguration. Cooperative payload manipulation design and analysis of cooperative mobile cable robots, building upon knowledge base of multi

Krovi, Venkat

457

On the use of doped polyethylene as an insulating material for HVDC cables  

SciTech Connect (OSTI)

The merits of HVDC cables with polymeric insulation are well recognized. However, the development of such cables is still hampered due to the problems resulting from the complicated dependence of the electrical conductivity of the polymer on the temperature and the dc electric field and the effects of space charge accumulation in this material. Different methods have been suggested to solve these problems yet none of these methods seem to give a conclusive solution. The present report provides, firstly a critical review of the previous works reported in the literature concerning the development of HVDC cables with polymeric insulation. Different aspects of those works are examined and discussed. Secondly, an account is given on an investigation using low density polyethylene (LDPE) doped with an inorganic additive as a candidate insulating material for HVDC cables. Preliminary results from measurements of dc breakdown strength and insulation resistivity of both the undoped and the doped materials are presented. It is shown that the incorporation of an inorganic additive into LDPE has improved the performance of the doped material under polarity reversal dc conditions at room temperature. Moreover, the dependency of the insulation resistivity on temperature for the doped material appears to be beneficially modified.

Khalil, M.S. [Sultan Qaboos Univ., Muscat (Oman)

1996-12-31T23:59:59.000Z

458

Characterization of underground cable incipient failures from on-line monitoring of underground distribution power systems  

E-Print Network [OSTI]

With the imminent re-regulation of the power industry and investor owned utilities becoming more cost conscious, the need for an on-line, non-destructive, incipient cable fault detection system is prevalent. With such an incipient fault detection...

Cardoso, Jesus

1999-01-01T23:59:59.000Z

459

System Voltage Potential-Induced Degradation Mechanisms in PV Modules and Methods for Test  

SciTech Connect (OSTI)

Over the past decade, degradation and power loss have been observed in PV modules resulting from the stress exerted by system voltage bias. This is due in part to qualification tests and standards that do not adequately evaluate for the durability of modules to the long-term effects of high voltage bias experienced in fielded arrays. High voltage can lead to module degradation by multiple mechanisms. The extent of the voltage bias degradation is linked to the leakage current or culombs passed from the silicon active layer through the encapsulant and glass to the grounded module frame, which can be experimentally determined; however, competing processes make the effect non-linear and history-dependent. Appropriate testing methods and stress levels are described that demonstrate module durability to system voltage potential-induced degradation (PID) mechanisms. This information, along with outdoor testing that is in progress, is used to estimate the acceleration factors needed to evaluate the durability of modules to system voltage stress. Na-rich precipitates are observed on the cell surface after stressing the module to induce PID in damp heat with negative bias applied to the active layer.

Hacke, P.; Terwilliger, K.; Smith, R.; Glick, S.; Pankow, J.; Kempe, M.; Kurtz, S.; Bennett, I.; Kloos, M.

2011-01-01T23:59:59.000Z

460

System Voltage Potential-Induced Degradation Mechanisms in PV Modules and Methods for Test: Preprint  

SciTech Connect (OSTI)

Over the past decade, degradation and power loss have been observed in PV modules resulting from the stress exerted by system voltage bias. This is due in part to qualification tests and standards that do not adequately evaluate for the durability of modules to the long-term effects of high voltage bias experienced in fielded arrays. High voltage can lead to module degradation by multiple mechanisms. The extent of the voltage bias degradation is linked to the leakage current or coulombs passed from the silicon active layer through the encapsulant and glass to the grounded module frame, which can be experimentally determined; however, competing processes make the effect non-linear and history-dependent. Appropriate testing methods and stress levels are described that demonstrate module durability to system voltage potential-induced degradation (PID) mechanisms. This information, along with outdoor testing that is in progress, is used to estimate the acceleration factors needed to evaluate the durability of modules to system voltage stress. Na-rich precipitates are observed on the cell surface after stressing the module to induce PID in damp heat with negative bias applied to the active layer.

Hacke, P.; Terwilliger, K.; Smith, R.; Glick, S.; Pankow, J.; Kempe, M.; Kurtz, S.; Bennett, I.; Kloos, M.

2011-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Group 3: Humidity, Temperature and Voltage (Presentation)  

SciTech Connect (OSTI)

This is a summary of the work of Group 3 of the International PV QA Task Force. Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

Wohlgemuth, J.

2013-09-01T23:59:59.000Z

462

Voltage control on a train system  

DOE Patents [OSTI]

The present invention provides methods for preventing low train voltages and managing interference, thereby improving the efficiency, reliability, and passenger comfort associated with commuter trains. An algorithm implementing neural network technology is used to predict low voltages before they occur. Once voltages are predicted, then multiple trains can be controlled to prevent low voltage events. Further, algorithms for managing inference are presented in the present invention. Different types of interference problems are addressed in the present invention such as "Interference During Acceleration", "Interference Near Station Stops", and "Interference During Delay Recovery." Managing such interference avoids unnecessary brake/acceleration cycles during acceleration, immediately before station stops, and after substantial delays. Algorithms are demonstrated to avoid oscillatory brake/acceleration cycles due to interference and to smooth the trajectories of closely following trains. This is achieved by maintaining sufficient following distances to avoid unnecessary braking/accelerating. These methods generate smooth train trajectories, making for a more comfortable ride, and improve train motor reliability by avoiding unnecessary mode-changes between propulsion and braking. These algorithms can also have a favorable impact on traction power system requirements and energy consumption.

Gordon, Susanna P.; Evans, John A.

2004-01-20T23:59:59.000Z

463

Capricious Cables: Understanding the Key Concepts in Transmission Expansion Planning and Its Models  

SciTech Connect (OSTI)

The extra-high-voltage transmission network is the bulk transport network of the electric power system. To understand how the future power system may react to planning decisions today, wide-area transmission models are increasingly used to aid decision makers and stakeholders. The goal of this work is to illuminate these models for a broader audience that may include policy makers or relative newcomers to the field of transmission planning. This paper explains the basic transmission expansion planning model formulation. It highlights six of the major simplifications made in transmission expansion planning models and the resulting need to contextualize model results using knowledge from other models and knowledge not captured in the modeling process.

Donohoo, P.; Milligan, M.

2014-06-01T23:59:59.000Z

464

Distribution System Voltage Regulation by Distributed Energy Resources  

SciTech Connect (OSTI)

This paper proposes a control method to regulate voltages in 3 phase unbalanced electrical distribution systems. A constrained optimization problem to minimize voltage deviations and maximize distributed energy resource (DER) active power output is solved by harmony search algorithm. IEEE 13 Bus Distribution Test System was modified to test three different cases: a) only voltage regulator controlled system b) only DER controlled system and c) both voltage regulator and DER controlled system. The simulation results show that systems with both voltage regulators and DER control provide better voltage profile.

Ceylan, Oguzhan [ORNL; Liu, Guodong [ORNL; Xu, Yan [ORNL; Tomsovic, Kevin [University of Tennessee, Knoxville (UTK)

2014-01-01T23:59:59.000Z

465

Multilevel Cascade H-bridge Inverter DC Voltage Estimation Through Output Voltage Sensing  

E-Print Network [OSTI]

system as the inverter power supply may vary. For example, interface of solar panels or fuel cell. The output voltage is then processed by a DSP unit that uses the signals that command the switches

Tolbert, Leon M.

466

Soft Magnetic Materials in High-Frequency, High-Power Conversion Applications  

E-Print Network [OSTI]

Voltage DC (HVDC) technologies aim to improve the effi- ciency of power networks and benefit from high

McHenry, Michael E.

467

Strategies for Voltage Control and Transient Stability Assessment  

SciTech Connect (OSTI)

As wind generation grows, its influence on power system performance will becoming increasingly noticeable. Wind generation di#11;ffers from traditional forms of generation in numerous ways though, motivating the need to reconsider the usual approaches to power system assessment and performance enhancement. The project has investigated the impact of wind generation on transient stability and voltage control, identifying and addressing issues at three distinct levels of the power system: 1) at the device level, the physical characteristics of wind turbine generators (WTGs) are quite unlike those of synchronous machines, 2) at the wind-farm level, the provision of reactive support is achieved through coordination of numerous dissimilar devices, rather than straightforward generator control, and 3) from a systems perspective, the location of wind-farms on the sub-transmission network, coupled with the variability inherent in their power output, can cause complex voltage control issues. The project has sought to develop a thorough understanding of the dynamic behaviour of type-3 WTGs, and in particular the WECC generic model. The behaviour of such models is governed by interactions between the continuous dynamics of state variables and discrete events associated with limits. It was shown that these interactions can be quite complex, and may lead to switching deadlock that prevents continuation of the trajectory. Switching hysteresis was proposed for eliminating deadlock situations. Various type-3 WTG models include control blocks that duplicate integrators. It was shown that this leads to non-uniqueness in the conditions governing steady-state, and may result in pre- and post-disturbance equilibria not coinciding. It also gives rise to a zero eigenvalue in the linearized WTG model. In order to eliminate the anomalous behaviour revealed through this investigation, WECC has now released a new generic model for type-3 WTGs. Wind-farms typically incorporate a variety of voltage control equipment including tapchanging transformers, switched capacitors, SVCs, STATCOMs and the WTGs themselves. The project has considered the coordinated control of this equipment, and has addressed a range of issues that arise in wind-farm operation. The #12;first concerns the ability of WTGs to meet reactive power requirements when voltage saturation in the collector network restricts the reactive power availability of individual generators. Secondly, dynamic interactions between voltage regulating devices have been investigated. It was found that under certain realistic conditions, tap-changing transformers may exhibit instability. In order to meet cost, maintenance, fault tolerance and other requirements, it is desirable for voltage control equipment to be treated as an integrated system rather than as independent devices. The resulting high-level scheduling of wind-farm reactive support has been investigated. In addressing this control problem, several forms of future information were considered, including exact future knowledge and stochastic predictions. Deterministic and Stochastic Dynamic Programming techniques were used in the development of control algorithms. The results demonstrated that while exact future knowledge is very useful, simple prediction methods yield little bene#12;fit. The integration of inherently variable wind generation into weak grids, particularly subtransmission networks that are characterized by low X=R ratios, aff#11;ects bus voltages, regulating devices and line flows. The meshed structure of these networks adds to the complexity, especially when wind generation is distributed across multiple nodes. A range of techniques have been considered for analyzing the impact of wind variability on weak grids. Sensitivity analysis, based on the power-flow Jacobian, was used to highlight sections of a system that are most severely a#11;ffected by wind-power variations. A continuation power flow was used to determine parameter changes that reduce the impact of wind-power variability. It was also used to explore interactions betw

Hiskens, Ian A.

2013-09-25T23:59:59.000Z

468

California's electricity system of the future scenario analysis in support of public-interest transmission system R&D planning  

E-Print Network [OSTI]

Voltage Direct Current (HVDC) 10. Underground Cables 11.E2I FACTS FERC GIL GMC GPS HVDC IEEE IOU ISO LADWP MD02 MJare minimal. High-voltage DC (HVDC) lines are not considered

Eto, Joseph; Stovall, John P.

2003-01-01T23:59:59.000Z

469

Reactive Support and Voltage Control Service: Key Issues and Challenges  

E-Print Network [OSTI]

reactive support and voltage control services. Keywords ­ Competitive Electricity Markets, Reactive PowerReactive Support and Voltage Control Service: Key Issues and Challenges George Gross^, Paolo Marannino° and Gianfranco Chicco* ^ Department of Electrical and Computer Engineering, University

Gross, George

470

Low Voltage White Phosphorescent OLED Achievements  

Broader source: Energy.gov [DOE]

Universal Display Corporation (UDC) and its research partners at Princeton University and the University of Southern California have succeeded in developing a white phosphorescent OLED (PHOLED™) that achieved a record efficiency of 20 lumens per watt. This achievement is the result of the team's collaborative efforts to increase the efficiency of PHOLED lighting by focusing on two critical factors: lowering the drive voltages and increasing the amount of light extracted.

471

The U.S. cable television industry : the multi-service operator organizational structure as a bundle of competencies  

E-Print Network [OSTI]

The United States cable television industry is experiencing fierce competition from telephone companies and content providers, as well as new and possibly unknown entrants. As organizations in the industry are currently ...

Moorthy, Satish K. (Satish Kumar)

2009-01-01T23:59:59.000Z

472

18 IEEE Transactions onPower Delivery, Vol. 14, No.1, January 1999 Leak Location in Fluid Filled Cables  

E-Print Network [OSTI]

such as corrosion, contractor damage, effects of stray currents, and localized pipe wear due to vibrations, a pipe. Self-contained, low and medium- pressure, fluid filled cables which have an oil channel in the middle

473

The Winch-Bot : a cable-suspended, under-actuated robot utilizing parametric self-excitation  

E-Print Network [OSTI]

A simple, compact, yet powerful robotic winch, called "Winch-Bot," is presented in this thesis. The Winch-Bot is an underactuated robot having only one controllable axis. Although hanging a load with merely one cable, it ...

Cunningham, Daniel Philip

2009-01-01T23:59:59.000Z

474

Electrostatically screened, voltage-controlled electrostatic chuck  

DOE Patents [OSTI]

Employing an electrostatically screened, voltage-controlled electrostatic chuck particularly suited for holding wafers and masks in sub-atmospheric operations will significantly reduce the likelihood of contaminant deposition on the substrates. The electrostatic chuck includes (1) an insulator block having a outer perimeter and a planar surface adapted to support the substrate and comprising at least one electrode (typically a pair of electrodes that are embedded in the insulator block), (2) a source of voltage that is connected to the at least one electrode, (3) a support base to which the insulator block is attached, and (4) a primary electrostatic shield ring member that is positioned around the outer perimeter of the insulator block. The electrostatic chuck permits control of the voltage of the lithographic substrate; in addition, it provides electrostatic shielding of the stray electric fields issuing from the sides of the electrostatic chuck. The shielding effectively prevents electric fields from wrapping around to the upper or front surface of the substrate, thereby eliminating electrostatic particle deposition.

Klebanoff, Leonard Elliott (San Ramon, CA)

2001-01-01T23:59:59.000Z

475

Design of Experiments to Determine Causes of Flex Cable Solder Wicking, Discoloration and Hole Location Defects  

SciTech Connect (OSTI)

Design of Experiments (DoE) were developed and performed in an effort to discover and resolve the causes of three different manufacturing issues; large panel voids after Hot Air Solder Leveling (HASL), cable hole locations out of tolerance after lamination and delamination/solder wicking around flat flex cable circuit lands after HASL. Results from a first DoE indicated large panel voids could be eliminated by removing the pre-HASL cleaning. It also revealed eliminating the pre-HASL bake would not be detrimental when using a hard press pad lamination stackup. A second DoE indicated a reduction in hard press pad stackup lamination pressure reduced panel stretch in the y axis approximately 70%. A third DoE illustrated increasing the pre-HASL bake temperature could reduce delamination/solder wicking when using a soft press pad lamination stackup.

Wolfe, Larry

2009-04-22T23:59:59.000Z

476

Microminiaturized minimally invasive intravascular micro-mechanical systems powered and controlled via fiber-optic cable  

DOE Patents [OSTI]

A micro-mechanical system for medical procedures is constructed in the basic form of a catheter having a distal end for insertion into and manipulation within a body and a near end providing for a user to control the manipulation of the distal end within the body. A fiberoptic cable is disposed within the catheter and having a distal end proximate to the distal end of the catheter and a near end for external coupling of laser light energy. A microgripper is attached to the distal end of the catheter and providing for the gripping or releasing of an object within the body. A laser-light-to-mechanical-power converter is connected to receive laser light from the distal end of the fiberoptic cable and connected to mechanically actuate the microgripper.

Fitch, Joseph P. (Livermore, CA); Hagans, Karla (Livermore, CA); Clough, Robert (Danville, CA); Matthews, Dennis L. (Moss Beach, CA); Lee, Abraham P. (Walnut Creek, CA); Krulevitch, Peter A. (Los Altos, CA); Benett, William J. (Livermore, CA); Da Silva, Luiz (Danville, CA); Celliers, Peter M. (Berkeley, CA)

1998-01-01T23:59:59.000Z

477

Superheated-steam test of ethylene propylene rubber cables using a simultaneous aging and accident environment  

SciTech Connect (OSTI)

The superheated-steam test exposed different ethylene propylene rubber (EPR) cables and insulation specimens to simultaneous aging and a 21-day simultaneous accident environment. In addition, some insulation specimens were exposed to five different aging conditions prior to the 21-day simultaneous accident simulation. The purpose of this superheated-steam test (a follow-on to the saturated-steam tests (NUREG/CR-3538)) was to: (1) examine electrical degradation of different configurations of EPR cables; (2) investigate differences between using superheated-steam or saturated-steam at the start of an accident simulation; (3) determine whether the aging technique used in the saturated-steam test induced artificial degradation; and (4) identify the constituents in EPR that affect moisture absorption.

Bennett, P.R.; St. Clair, S.D.; Gilmore, T.W.

1986-06-01T23:59:59.000Z

478

Correlation of superconductor strand, cable, and dipole critical currents in CBA magnets  

SciTech Connect (OSTI)

A calibration between vendor critical current data for 0.0268'' diameter superconductor strand supplied to Fermilab, and the BNL 10/sup -12/..cap omega..cm critical current specification is presented. Vendor critical current data for over 400 Fermilab type billets are shown, both as supplied by the vendor and converted to BNL units. Predictions of cable critical current are made using the sum of the critical currents of the 23 strands, where all strands from the same half billet are assigned the same critical current. The measured critical current shows excellent correlation to the predicted value and is approximately 14 +- 2 percent below it. Colliding Beam Accelerator (CBA) full length dipoles reach the conductor critical current limit, essentially without training. Magnet performance is predictable from the measured critical current of a short sample of cable to within 2%.

Tannenbaum, M.J.; Garber, M.; Sampson, W.B.

1982-01-01T23:59:59.000Z

479

Fluid dynamics of supercritical hellium within cable-in-conduit conductors. Progress report  

SciTech Connect (OSTI)

The enclosed report summarizes work carried out under DOE/MFE Support, during the past four years. Emphasis is placed on progress within the last year. Results of experiments on pressure drop and heat transfer within several Cable-in-Conduit Conductors are described. These results are compared to models for flow in similar geometrics. The work provides a basis for design of magnets using the CIC Conductor Concept.

Van Sciver, S.W.

1992-07-01T23:59:59.000Z

480

Fluid dynamics of supercritical hellium within cable-in-conduit conductors  

SciTech Connect (OSTI)

The enclosed report summarizes work carried out under DOE/MFE Support, during the past four years. Emphasis is placed on progress within the last year. Results of experiments on pressure drop and heat transfer within several Cable-in-Conduit Conductors are described. These results are compared to models for flow in similar geometrics. The work provides a basis for design of magnets using the CIC Conductor Concept.

Van Sciver, S.W.

1992-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "high voltage cables" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

K.K. Gan DPF/JPS06 1 Bandwidths of Micro Twisted-Pair Cables  

E-Print Network [OSTI]

/fall time after irradiation? What is optical power after irradiation? What current is needed for annealing during irradiation SLHC AOC 71 MRad 0.0 0.3 0.6 0.9 1.2 1.5 1.8 0 100 200 300 400 Time (Hours) DataOpticalPK.K. Gan DPF/JPS06 1 Bandwidths of Micro Twisted-Pair Cables and Fusion Spliced SIMM-GRIN Fibers

Gan, K. K.

482

Selective compensation of voltage harmonics in grid-connected microgrids  

E-Print Network [OSTI]

1 Selective compensation of voltage harmonics in grid-connected microgrids Mehdi Savaghebia , Juan is proposed for selective compensation of main voltage harmonics in a grid- connected microgrid. The aim level. Keywords Distributed Generator (DG); microgrid; grid-connected; voltage harmonics compensation. 1

Vasquez, Juan Carlos

483

LM2907LM2917FrequencytoVoltageConverter February 1995  

E-Print Network [OSTI]

TL H 7942 LM2907LM2917FrequencytoVoltageConverter February 1995 LM2907 LM2917 Frequency to Voltage Converter General Description The LM2907 LM2917 series are monolithic frequency to voltage converters doubling for low ripple full input protection in two versions (LM2907-8 LM2917-8) and its output swings

Wedeward, Kevin

484

Characterized ideal LC circuit Charge, current and voltage vary sinusoidally  

E-Print Network [OSTI]

resistance to LC circuit Oscillations become damped Charge, current and voltage still vary sinusoidally Oscillations Draw phasors for voltages of R, C and L at same time t Orient VR, VL, & VC phasors relativeReview Characterized ideal LC circuit Charge, current and voltage vary sinusoidally Added

Bertulani, Carlos A. - Department of Physics and Astronomy, Texas A&M University

485

Accurately measuring current-voltage characteristics of tunnel diodes  

E-Print Network [OSTI]

of the bias voltage range of oscillations in the I–V curve.and the bias voltage range of oscillation in the I–V curve.or to know the exact voltage range of oscillation in the I–V

Bao, Mingqiang; Wang, Kang L

2006-01-01T23:59:59.000Z

486

DCS1800/WCDMA ADAPTIVE VOLTAGE-CONTROLLED OSCILLATOR  

E-Print Network [OSTI]

DCS1800/WCDMA ADAPTIVE VOLTAGE-CONTROLLED OSCILLATOR Aleksandar Tasiü, Wouter A. Serdijn and John R, an adaptive 2G/3G voltage-controlled oscillator (VCO) is described in this paper. For the DCS1800 operation with this reasoning, an adaptive 2G/3G voltage- controlled oscillator, meant for a dual-standard adaptive front

Serdijn, Wouter A.

487

System for increasing corona inception voltage of insulating oils  

DOE Patents [OSTI]

The Corona Inception Voltage of insulating oils is increased by repetitive cycles of prestressing the oil with a voltage greater than the corona inception voltage, and either simultaneously or serially removing byproducts of corona by evacuation and heating the oil. 5 figs.

Rohwein, G.J.

1998-05-19T23:59:59.000Z