Sample records for high temporal resolution

  1. The Importance of High Temporal Resolution in Modeling Renewable Energy Penetration Scenarios

    SciTech Connect (OSTI)

    Nicolosi, Marco; Mills, Andrew D; Wiser, Ryan H

    2010-10-08T23:59:59.000Z

    Traditionally, modeling investment and dispatch problems in electricity economics has been limited by computation power. Due to this limitation, simplifications are applied. One common practice, for example, is to reduce the temporal resolution of the dispatch by clustering similar load levels. The increase of intermittent electricity from renewable energy sources (RES-E) changes the validity of this assumption. RES-E already cover a certain amount of the total demand. This leaves an increasingly volatile residual demand to be matched by the conventional power market. This paper quantifies differences in investment decisions by applying three different time-resolution residual load patterns in an investment and dispatch power system model. The model optimizes investment decisions in five year steps between today and 2030 with residual load levels for 8760, 288 and 16 time slices per year. The market under consideration is the four zone ERCOT market in Texas. The results show that investment decisions significantly differ across the three scenarios. In particular, investments into base-load technologies are substantially reduced in the high resolution scenario (8760 residual load levels) relative to the scenarios with lower temporal resolution. Additionally, the amount of RES-E curtailment and the market value of RES-E exhibit noteworthy differences.

  2. High spatial and temporal resolution charge exchange recombination spectroscopy on the HL-2A tokamak

    SciTech Connect (OSTI)

    Wei, Y. L.; Yu, D. L., E-mail: yudl@swip.ac.cn; Liu, L.; Cao, J. Y.; Sun, A. P.; Ma, Q.; Chen, W. J.; Liu, Yi; Yan, L. W.; Yang, Q. W.; Duan, X. R.; Liu, Yong [Southwestern Institute of Physics, Chengdu 610041 (China); Ida, K. [National Institute for Fusion Science, Toki 509-5292 (Japan); Hellermann, M. von [ITER Diagnostic Team, IO, Route de Vinon sur Verdon, 13115 St Paul lez Durance (France); FOM-Institute for Plasma physics “Rijnhuizen,” Association EURATOM, Trilateral Euregio Cluster, 3430 BE Nieuwegein (Netherlands)

    2014-10-01T23:59:59.000Z

    A 32/64-channel charge exchange recombination spectroscopy (CXRS) diagnostic system is developed on the HL-2A tokamak (R = 1.65 m, a = 0.4 m), monitoring plasma ion temperature and toroidal rotation velocity simultaneously. A high throughput spectrometer (F/2.8) and a pitch-controlled fiber bundle enable the temporal resolution of the system up to 400 Hz. The observation geometry and an optimized optic system enable the highest radial resolution up to ~1 cm at the plasma edge. The CXRS system monitors the carbon line emission (C VI, n = 8–7, 529.06 nm) whose Doppler broadening and Doppler shift provide ion temperature and plasma rotation velocity during the neutral beam injection. The composite CX spectral data are analyzed by the atomic data and analysis structure charge exchange spectroscopy fitting (ADAS CXSFIT) code. First experimental results are shown for the case of HL-2A plasmas with sawtooth oscillations, electron cyclotron resonance heating, and edge transport barrier during the high-confinement mode (H-mode)

  3. Probing Structural Dynamics with High Spatial and Temporal Resolution Research Team: Nigel Browning, James Evans, Patricia Abellan, Russell Tonkyn

    E-Print Network [OSTI]

    Probing Structural Dynamics with High Spatial and Temporal Resolution Research Team: Nigel Browning of the structural dynamics that occur on the µs-ns timescale We will make use of a unique aberration-corrected dynamic TEM (DTEM), where a photoemission source will enable these time-resolved images to be obtained at

  4. Optical Monitoring of BL Lac Object S5 0716+714 with High Temporal Resolution

    E-Print Network [OSTI]

    Jianghua Wu; Bo Peng; Xu Zhou; Jun Ma; Zhaoji Jiang; Jiansheng Chen

    2005-01-11T23:59:59.000Z

    Optical monitoring of S5 0716+714 was performed with a 60/90 Schmidt telescope in 2003 November and December and 2004 January for studying the variability of the object on short timescales. Due to the high brightness of the source we could carry out quasi-simultaneous measurements in three bands with a temporal resolution of about 20 minutes by using one single telescope. Intraday and intranight variations were observed with an overall change of ~0.9 mag during the whole campaign. Two outbursts were recorded on JD 2453005 and JD 2453009. Minimum timescales of a few hours were derived from the light curves of individual nights but were different from night to night. A bluer-when-brighter chromatism was present when the object was in fast flare, but was absent when it was in a relatively quiescent state. Our results are basically consistent with the shock-in-jet model and demonstrate that the geometrical effects can sometimes play an important role in the variability of blazars.

  5. Atmospheric inverse modeling to constrain regionalscale CO2 budgets at high spatial and temporal resolution

    E-Print Network [OSTI]

    Michalak, Anna M.

    a simple diagnostic flux model that splits the net ecosystem exchange into its major components of gross stateoftheart data sets for advected background CO2 and anthropogenic fossil fuel emissions as well as highly grid cell, thus permitting description of the surface in a very high resolution. The model is tested

  6. LandScan USA: A High Resolution Geospatial and Temporal Modeling Approach for Population Distribution and Dynamics

    SciTech Connect (OSTI)

    Bhaduri, Budhendra L [ORNL; Bright, Eddie A [ORNL; Coleman, Phil R [ORNL; Urban, Marie L [ORNL

    2007-01-01T23:59:59.000Z

    High resolution population distribution data are critical for successfully addressing important issues ranging from socio-environmental research to public health to homeland security, since scientific analyses, operational activities, and policy decisions are significantly influenced by the number of impacted people. Dasymetric modeling has been a well recognized approach for spatial decomposition of census data to increase the spatial resolution of population distribution. However, enhancing the temporal resolution of population distribution poses a greater challenge. In this paper, we discuss the development of LandScan USA, a multi-dimensional dasymetric modeling approach, which has allowed creation of very high resolution population distribution data both over space and time. At a spatial resolution of 3 arc seconds (~90m), the initial LandScan USA database contains both a nighttime residential as well as a baseline daytime population distribution that incorporates movement of workers and students. Challenging research issues of disparate and misaligned spatial data integration and modeling to develop a database at a national scale, as well as model verification and validation approaches are illustrated and discussed. Initial analyses indicate a high degree of accuracy for LandScan USA distribution model and data. High resolution population data such as LandScan USA, which describes both distribution and dynamics of human population, clearly has the potential to profoundly impact on multiple domain applications of national and global priority.

  7. High-resolution temporal constraints on the dynamics of dark energy

    E-Print Network [OSTI]

    Gong-Bo Zhao; Dragan Huterer; Xinmin Zhang

    2008-05-18T23:59:59.000Z

    We use the recent type Ia supernova, cosmic microwave background and large-scale structure data to shed light on the temporal evolution of the dark energy equation of state $w(z)$ out to redshift one. We constrain the most flexible parametrization of dark energy to date, and include the dark energy perturbations consistently throughout. Interpreting our results via the principal component analysis, we find no significant evidence for dynamical dark energy: the cosmological constant model is consistent with data everywhere between redshift zero and one at 95% C.L.

  8. The Importance of High Temporal Resolution in Modeling Renewable Energy Penetration Scenarios

    E-Print Network [OSTI]

    Nicolosi, Marco

    2011-01-01T23:59:59.000Z

    Superpeaker OCGT CCGT Coal Nuclear Generation Capacities [generation options considered in THEA are nuclear, coal,Generation Share [%] Wind Low Wind Scenario High Wind Scenario Hydro Superpeaker OCGT CCGT Coal

  9. Zoomed Functional Imaging in the Human Brain at 7 Tesla with Simultaneous High Spatial and High Temporal Resolution

    E-Print Network [OSTI]

    Zoomed Functional Imaging in the Human Brain at 7 Tesla with Simultaneous High Spatial and High and is mainly limited by sensitivity. Here, signal-to-noise gains at high magnetic fields (7 Tesla

  10. Femtosecond Time-Resolved Optical and Raman Spectroscopy of Photoinduced Spin Crossover: Temporal Resolution of Low-to-High Spin

    E-Print Network [OSTI]

    McCusker, James K.

    an intriguing class of compounds in this regard due to their potential utility in solar energy conversion Resolution of Low-to-High Spin Optical Switching Amanda L. Smeigh, Mark Creelman, Richard A. Mathies(tren(6-R-py)3)]2+ (R ) H (1), CH3 (2)), which is illustrated in Chart 1 along with a simplified energy

  11. High Resolution EELS | EMSL

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    EELS EMSL's ultrahigh vacuum (UHV) surface chemistry-high-resolution electron energy loss spectroscopy (HREELS) system is designed to study the molecular-level chemistry...

  12. Single-shot 35 fs temporal resolution electron shadowgraphy

    SciTech Connect (OSTI)

    Scoby, C. M.; Li, R. K.; Threlkeld, E.; To, H.; Musumeci, P. [Department of Physics and Astronomy, UCLA, Los Angeles, California 90095 (United States)] [Department of Physics and Astronomy, UCLA, Los Angeles, California 90095 (United States)

    2013-01-14T23:59:59.000Z

    We obtain single-shot time-resolved shadowgraph images of the electromagnetic fields resulting from the interaction of a high intensity ultrashort laser pulse with a metal surface. Using a high brightness relativistic electron beam and a high streaking speed radiofrequency deflector, we report <35 fs temporal resolution enabling a direct visualization of the retarded-time dominated field evolution which follows the laser-induced charge emission. A model including the finite signal propagation speed well reproduces the data and yields measurements of fundamental parameters in short pulse laser-matter interaction such as the amount of emitted charge and the emission time scale.

  13. High resolution data acquisition

    DOE Patents [OSTI]

    Thornton, G.W.; Fuller, K.R.

    1993-04-06T23:59:59.000Z

    A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock, pulse train, and analog circuitry for generating a triangular wave synchronously with the pulse train (as seen in diagram on patent). The triangular wave has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter counts the clock pulse train during the interval to form a gross event interval time. A computer then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.

  14. High resolution data acquisition

    DOE Patents [OSTI]

    Thornton, Glenn W. (Los Alamos, NM); Fuller, Kenneth R. (Los Alamos, NM)

    1993-01-01T23:59:59.000Z

    A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock (38) pulse train (37) and analog circuitry (44) for generating a triangular wave (46) synchronously with the pulse train (37). The triangular wave (46) has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter (18, 32) forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter (26) counts the clock pulse train (37) during the interval to form a gross event interval time. A computer (52) then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.

  15. High resolution time interval meter

    DOE Patents [OSTI]

    Martin, A.D.

    1986-05-09T23:59:59.000Z

    Method and apparatus are provided for measuring the time interval between two events to a higher resolution than reliability available from conventional circuits and component. An internal clock pulse is provided at a frequency compatible with conventional component operating frequencies for reliable operation. Lumped constant delay circuits are provided for generating outputs at delay intervals corresponding to the desired high resolution. An initiation START pulse is input to generate first high resolution data. A termination STOP pulse is input to generate second high resolution data. Internal counters count at the low frequency internal clock pulse rate between the START and STOP pulses. The first and second high resolution data are logically combined to directly provide high resolution data to one counter and correct the count in the low resolution counter to obtain a high resolution time interval measurement.

  16. High Resolution Nanoimprint for Nanophotonics 

    E-Print Network [OSTI]

    Jiang, Youwei

    2014-04-28T23:59:59.000Z

    of SERS-active device depends on two main factors: good reproducibility and high enhancement factor. Ordered metallic nanostructures with high resolution are usually preferred for SERS application. Nanoimprint lithography can provide a low-cost and high...

  17. High resolution telescope

    DOE Patents [OSTI]

    Massie, Norbert A. (San Ramon, CA); Oster, Yale (Danville, CA)

    1992-01-01T23:59:59.000Z

    A large effective-aperture, low-cost optical telescope with diffraction-limited resolution enables ground-based observation of near-earth space objects. The telescope has a non-redundant, thinned-aperture array in a center-mount, single-structure space frame. It employs speckle interferometric imaging to achieve diffraction-limited resolution. The signal-to-noise ratio problem is mitigated by moving the wavelength of operation to the near-IR, and the image is sensed by a Silicon CCD. The steerable, single-structure array presents a constant pupil. The center-mount, radar-like mount enables low-earth orbit space objects to be tracked as well as increases stiffness of the space frame. In the preferred embodiment, the array has elemental telescopes with subaperture of 2.1 m in a circle-of-nine configuration. The telescope array has an effective aperture of 12 m which provides a diffraction-limited resolution of 0.02 arc seconds. Pathlength matching of the telescope array is maintained by an electro-optical system employing laser metrology. Speckle imaging relaxes pathlength matching tolerance by one order of magnitude as compared to phased arrays. Many features of the telescope contribute to substantial reduction in costs. These include eliminating the conventional protective dome and reducing on-site construction activites. The cost of the telescope scales with the first power of the aperture rather than its third power as in conventional telescopes.

  18. Enhanced High Resolution RBS System

    SciTech Connect (OSTI)

    Pollock, Thomas J.; Hass, James A.; Klody, George M. [National Electrostatics Corp., Middleton, Wisconsin, U. S. A. 53562-0310 (United States)

    2011-06-01T23:59:59.000Z

    Improvements in full spectrum resolution with the second NEC high resolution RBS system are summarized. Results for 50 A ring TiN/HfO films on Si yielding energy resolution on the order of 1 keV are also presented. Detector enhancements include improved pulse processing electronics, upgraded shielding for the MCP/RAE detector, and reduced noise generated from pumping. Energy resolution measurements on spectra front edge coupled with calculations using 0.4mStr solid angle show that beam energy spread at 400 KeV from the Pelletron registered accelerator is less than 100 eV. To improve user throughput, magnet control has been added to the automatic data collection. Depth profiles derived from experimental data are discussed. For the thin films profiled, depth resolutions were on the Angstrom level with the non-linear energy/channel conversions ranging from 100 to 200 eV.

  19. High Resolution Timing with Low Resolution Clocks A Microsecond Resolution Timer for Sun Workstations

    E-Print Network [OSTI]

    Melvin, Stephen

    High Resolution Timing with Low Resolution Clocks and A Microsecond Resolution Timer for Sun for Sun 3 and Sun 4 workstations1. One can measure average service times without a high resolution clock?" 1. Introduction - Who Needs a Microsecond Clock Beginning with its Sun 3 workstations, Sun

  20. Turbo ASL: Arterial Spin Labeling With Higher SNR and Temporal Resolution

    E-Print Network [OSTI]

    Sereno, Martin

    Turbo ASL: Arterial Spin Labeling With Higher SNR and Temporal Resolution Eric C. Wong,* Wen the ASL SNR per image. We refer to this modified technique as turbo ASL. THEORY In pulsed ASL techniques

  1. advanced high resolution: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Resolution Imaging Spectrometer (MODIS) to calibrate advanced very high resolution radiometer Geosciences Websites Summary: Using Moderate Resolution Imaging Spectrometer (MODIS)...

  2. Analysis of the High-Resolution Infrared Spectrum of Cyclopropane...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    the High-Resolution Infrared Spectrum of Cyclopropane. Analysis of the High-Resolution Infrared Spectrum of Cyclopropane. Abstract: The high resolution infrared spectrum of...

  3. HIGH RESOLUTION SCANNING AUGER MICROANALYSIS OF HIGH-STRENGTH SILICON CARBIDES

    E-Print Network [OSTI]

    Krivanek, O.L.

    2012-01-01T23:59:59.000Z

    Society HIGH RESOLUTION SCANNING AUGER MICROANALYSIS OFCalifornia. HIGH RESOLUTION SCANNING AUGER MICROANALYSIS OFhelium, by high resolution scanning Auger microanalysis and

  4. Ultra-High Resolution Electron Microscopy for Catalyst Characterizatio...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Documents & Publications Ultra-High Resolution Electron Microscopy for Catalyst Characterization Ultra-high Resolution Electron Microscopy for Catalyst Characterization...

  5. High resolution scintillation detector with semiconductor readout

    DOE Patents [OSTI]

    Levin, Craig S. (Santa Monica, CA); Hoffman, Edward J. (Los Angeles, CA)

    2000-01-01T23:59:59.000Z

    A novel high resolution scintillation detector array for use in radiation imaging such as high resolution Positron Emission Tomography (PET) which comprises one or more parallelepiped crystals with at least one long surface of each crystal being in intimate contact with a semiconductor photodetector such that photons generated within each crystal by gamma radiation passing therethrough is detected by the photodetector paired therewith.

  6. Identifying chromatin interactions at high spatial resolution

    E-Print Network [OSTI]

    Reeder, Christopher Campbell

    2014-01-01T23:59:59.000Z

    This thesis presents two computational approaches for identifying chromatin interactions at high spatial resolution from ChIA-PET data. We introduce SPROUT which is a hierarchical probabilistic model that discovers high ...

  7. Increasing Temporal Resolution in Greenland Ablation Estimation Using Passive and Active Microwave Data

    E-Print Network [OSTI]

    Long, David G.

    Increasing Temporal Resolution in Greenland Ablation Estimation Using Passive and Active Microwave of these measurements provides an increased understanding of the diurnal melt cycle over Greenland and estimation of the melt profile. I. INTRODUCTION Accurate estimation of the mass balance of the Greenland ice sheet

  8. GEOPHYSICAL RESEARCH LETTERS, VOL. ???, XXXX, DOI:10.1029/, Source geometry from exceptionally high resolution

    E-Print Network [OSTI]

    Boyer, Edmond

    resolution Long Period event observations at Mt Etna during the 2008 eruption. Louis De Barros 1 to the summit, allowing us to observe seismic activity with exceptionally high resolution. 129 Long Period. These events form two families of similar wave- forms with different temporal distributions. Event locations

  9. High resolution studies of massive primordial haloes

    E-Print Network [OSTI]

    Latif, M A; Schmidt, W; Niemeyer, J

    2012-01-01T23:59:59.000Z

    Atomic cooling haloes with T_vir > 10^4 K are the most plausible sites for the formation of the first galaxies. In this article, we aim to study the implications of gravity driven turbulence in protogalactic haloes. By varying the resolution per Jeans length, we explore whether the turbulent cascade is resolved well enough to obtain converged results. We have performed high resolution cosmological simulations using the adaptive mesh refinement code Enzo including a subgrid-scale turbulence model to study the role of unresolved turbulence. We compared the results of three different Jeans resolutions from 16 to 64 cells. While radially averaged profiles roughly agree at different resolutions, differences in the morphology reveal that even the highest resolution employed provides no convergence. Moreover, taking into account unresolved turbulence significantly influences the morphology of a halo. We have quantified the properties of the high-density clumps in the halo. These clumps are gravitationally unbound wi...

  10. Tactile Feedback Display with Spatial and Temporal Resolutions

    E-Print Network [OSTI]

    Wang, Deli

    actuators made of an interpenetrating polymer elastomer network. Digital replay, editing and manipulation of the force is also shown possible using the polymer actuators, despite of the high driving voltage physical learning, social networking, e-commerce, robotics, gaming, medical and military applications

  11. arecibo high resolution: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    84 Using Moderate Resolution Imaging Spectrometer (MODIS) to calibrate advanced very high resolution radiometer Geosciences Websites Summary: Using Moderate Resolution Imaging...

  12. Radiometry High Spectral Resolution Fourier

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's PossibleRadiation Protection Radiation Protection Regulations:Radiological Threat Reduction2High

  13. High-Resolution PET Detector. Final report

    SciTech Connect (OSTI)

    Karp, Joel

    2014-03-26T23:59:59.000Z

    The objective of this project was to develop an understanding of the limits of performance for a high resolution PET detector using an approach based on continuous scintillation crystals rather than pixelated crystals. The overall goal was to design a high-resolution detector, which requires both high spatial resolution and high sensitivity for 511 keV gammas. Continuous scintillation detectors (Anger cameras) have been used extensively for both single-photon and PET scanners, however, these instruments were based on NaI(Tl) scintillators using relatively large, individual photo-multipliers. In this project we investigated the potential of this type of detector technology to achieve higher spatial resolution through the use of improved scintillator materials and photo-sensors, and modification of the detector surface to optimize the light response function.We achieved an average spatial resolution of 3-mm for a 25-mm thick, LYSO continuous detector using a maximum likelihood position algorithm and shallow slots cut into the entrance surface.

  14. Analysis of Rotational Structure in the High-Resolution Infrared...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Rotational Structure in the High-Resolution Infrared Spectrum and Assignment of Vibrational Fundamentals of Analysis of Rotational Structure in the High-Resolution Infrared...

  15. Merging high resolution geophysical and geochemical surveys to...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    high resolution geophysical and geochemical surveys to reduce exploration risk at Glass Buttes, Oregon Merging high resolution geophysical and geochemical surveys to reduce...

  16. New generation NMR bioreactor coupled with high-resolution NMR...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    New generation NMR bioreactor coupled with high-resolution NMR spectroscopy leads to novel discoveries in Moorella New generation NMR bioreactor coupled with high-resolution NMR...

  17. Coherent Vibrational Dynamics and High-Resolution Nonlinear Spectrosco...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Vibrational Dynamics and High-Resolution Nonlinear Spectroscopy: A Comparison with the AirDMSO Liquid Interface. Coherent Vibrational Dynamics and High-Resolution Nonlinear...

  18. Applications of High-Resolution Electrospray Ionization Mass...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    High-Resolution Electrospray Ionization Mass Spectrometry to Measurements of Average Oxygen to Carbon Ratios in Applications of High-Resolution Electrospray Ionization Mass...

  19. Sandia Energy - High-Resolution Computational Algorithms for...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    High-Resolution Computational Algorithms for Simulating Offshore Wind Farms Home Stationary Power Energy Conversion Efficiency Wind Energy Offshore Wind High-Resolution...

  20. Supercomputers Fuel Global High-Resolution Climate Models

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Supercomputers Fuel Global High-Resolution Climate Models Supercomputers Fuel Global High-Resolution Climate Models Berkeley Lab Researcher Says Climate Science is Entering New...

  1. Ultra-high Resolution Electron Microscopy for Catalyst Characterizatio...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    high Resolution Electron Microscopy for Catalyst Characterization Ultra-high Resolution Electron Microscopy for Catalyst Characterization 2009 DOE Hydrogen Program and Vehicle...

  2. Ultra-High Resolution Electron Microscopy for Catalyst Characterizatio...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Documents & Publications Ultra-High Resolution Electron Microscopy for Catalyst Characterization Ultra-high Resolution Electron Microscopy for Catalyst Characterization Catalyst...

  3. High Resolution and Low-Temperature Photoelectron Spectroscopy...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    High Resolution and Low-Temperature Photoelectron Spectroscopy of an Oxygen-Linked Fullerene Dimer Dianion: C120O2-. High Resolution and Low-Temperature Photoelectron Spectroscopy...

  4. Detection power, temporal response, and spatial resolution of IRON fMRI in awake, behaving monkeys at 3 Tesla

    E-Print Network [OSTI]

    Leite, Francisca Maria Pais Horta

    2007-01-01T23:59:59.000Z

    The main goal of this thesis was to systematically characterize the detection sensitivity, temporal response, and spatial resolution of IRON contrast for fMRI within the awake, behaving monkey. Understanding these issues ...

  5. Satellite data for high resolution offshore wind resource mapping: A data fusion approach M.B. Ben Ticha a,*

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Satellite data for high resolution offshore wind resource mapping: A data fusion approach M.B. Ben accurate high spatial and temporal resolutions wind measurements. Offshore, satellite data are an accurate radar, scatterometer, data fusion, offshore wind energy resource assessment. 1. INTRODUCTION Since

  6. High resolution patterning of silica aerogels

    SciTech Connect (OSTI)

    Bertino, M.F.; Hund, J.F.; Sosa, J.; Zhang, G.; Sotiriou-Leventis, C.; Leventis, N.; Tokuhiro, A.T.; Terry, J. (UMR-MUST); (IIT)

    2008-10-30T23:59:59.000Z

    Three-dimensional metallic structures are fabricated with high spatial resolution in silica aerogels. In our method, silica hydrogels are prepared with a standard base-catalyzed route, and exchanged with an aqueous solution typically containing Ag{sup +} ions (1 M) and 2-propanol (0.2 M). The metal ions are reduced photolytically with a table-top ultraviolet lamp, or radiolytically, with a focused X-ray beam. We fabricated dots and lines as small as 30 x 70 {micro}m, protruding for several mm into the bulk of the materials. The hydrogels are eventually supercritically dried to yield aerogels, without any measurable change in the shape and spatial resolution of the lithographed structures. Transmission electron microscopy shows that illuminated regions are composed by Ag clusters with a size of several {micro}m, separated by thin layers of silica.

  7. Earthquake Damage Identification using High-Resolution Satellite

    E-Print Network [OSTI]

    Shinozuka, Masanobu

    Earthquake Damage Identification using High-Resolution Satellite Images from the 2003 Northern & evaluation · High-resolution satellite imagery · Images from Boumerdes, Algeria · Semi-automated damage are most damaged? ­ Effects in less populated areas · Earthquake reconnaissance time wasted "looking

  8. Ultra-high resolution computed tomography imaging

    DOE Patents [OSTI]

    Paulus, Michael J. (Knoxville, TN); Sari-Sarraf, Hamed (Knoxville, TN); Tobin, Jr., Kenneth William (Harriman, TN); Gleason, Shaun S. (Knoxville, TN); Thomas, Jr., Clarence E. (Knoxville, TN)

    2002-01-01T23:59:59.000Z

    A method for ultra-high resolution computed tomography imaging, comprising the steps of: focusing a high energy particle beam, for example x-rays or gamma-rays, onto a target object; acquiring a 2-dimensional projection data set representative of the target object; generating a corrected projection data set by applying a deconvolution algorithm, having an experimentally determined a transfer function, to the 2-dimensional data set; storing the corrected projection data set; incrementally rotating the target object through an angle of approximately 180.degree., and after each the incremental rotation, repeating the radiating, acquiring, generating and storing steps; and, after the rotating step, applying a cone-beam algorithm, for example a modified tomographic reconstruction algorithm, to the corrected projection data sets to generate a 3-dimensional image. The size of the spot focus of the beam is reduced to not greater than approximately 1 micron, and even to not greater than approximately 0.5 microns.

  9. Communication: Spectroscopic phase and lineshapes in high-resolution...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Communication: Spectroscopic phase and lineshapes in high-resolution broadband sum frequency vibrational spectroscopy: Resolving Communication: Spectroscopic phase and lineshapes...

  10. RESEARCH ARTICLE High-resolution climate change mapping with gridded

    E-Print Network [OSTI]

    Vermont, University of

    RESEARCH ARTICLE High-resolution climate change mapping with gridded historical climate products of climate research and adaptation efforts around the world. High-resolution gridded historical climate (GHC products to produce high-resolution temperature trend maps for the US Northeast from 1980 to 2009

  11. CLINICAL SCIENCES High-Speed UltraHigh-Resolution Optical

    E-Print Network [OSTI]

    Srinivasan, Vivek J.

    of the perifoveal pho- toreceptor inner segment/outer segment junction and thin- ning of the outer nuclear layer- velopedbyourgroupforuseintheophthal- mologyclinicattheNewEnglandEyeCen- ter,Boston,Mass.Thissystemusesspectral or­high-resolutionOCTenablessuperior visualizationofretinalmorphologyinanum- Author Affiliations: New England Eye Center, Tufts­New England Medical Center, Tufts University

  12. Minimally invasive diagnostic imaging using high resolution Optical Coherence Tomography

    E-Print Network [OSTI]

    Herz, Paul Richard, 1972-

    2004-01-01T23:59:59.000Z

    Advances in medical imaging have given researchers unprecedented capabilities to visualize, characterize and understand biological systems. Optical Coherence Tomography (OCT) is a high speed, high resolution imaging technique ...

  13. PROBING NEAR-SURFACE ATMOSPHERIC TURBULENCE WITH LIDAR MEASUREMENTS AND HIGH-RESOLUTION HYDRODYNAMIC MODELS

    SciTech Connect (OSTI)

    J. KAO; D. COOPER; ET AL

    2000-11-01T23:59:59.000Z

    As lidar technology is able to provide fast data collection at a resolution of meters in an atmospheric volume, it is imperative to promote a modeling counterpart of the lidar capability. This paper describes an integrated capability based on data from a scanning water vapor lidar and a high-resolution hydrodynamic model (HIGRAD) equipped with a visualization routine (VIEWER) that simulates the lidar scanning. The purpose is to better understand the spatial and temporal representativeness of the lidar measurements and, in turn, to extend their utility in studying turbulence fields in the atmospheric boundary layer. Raman lidar water vapor data collected over the Pacific warm pool and the simulations with the HIGRAD code are used for identifying the underlying physics and potential aliasing effects of spatially resolved lidar measurements. This capability also helps improve the trade-off between spatial-temporal resolution and coverage of the lidar measurements.

  14. High resolution EUV monochromator/spectrometer

    DOE Patents [OSTI]

    Koike, Masako (Moraga, CA)

    1996-01-01T23:59:59.000Z

    This invention is related to a monochromator which employs a spherical mirror, a traveling plane mirror with simultaneous rotation, and a varied spacing plane grating. The divergent beam from the entrance slit is converged by the spherical mirror located at the various positions in the monochromator depending of the inventive system. To provide the meaningful diffraction efficiencies and to reduce unwanted higher order lights, the deviation angle subtending the incidence and diffraction beams for the plane grating is varied with the position of the traveling plane mirror with simultaneous rotation located in the front or back of the plane grating with wavelength scanning. The outgoing beam from the monochromator goes through the fixed exit slit and has same beam direction regardless of the scanning wavelength. The combination of properly designed motions of the plane mirror and novel varied-spacing parameters of the inventive plane grating corrects the aberrations and focuses the monochromatic spectral image on the exit slit, enabling measurements at high spectral resolution.

  15. High resolution EUV monochromator/spectrometer

    DOE Patents [OSTI]

    Koike, Masako

    1996-06-18T23:59:59.000Z

    This invention is related to a monochromator which employs a spherical mirror, a traveling plane mirror with simultaneous rotation, and a varied spacing plane grating. The divergent beam from the entrance slit is converged by the spherical mirror located at the various positions in the monochromator depending of the inventive system. To provide the meaningful diffraction efficiencies and to reduce unwanted higher order lights, the deviation angle subtending the incidence and diffraction beams for the plane grating is varied with the position of the traveling plane mirror with simultaneous rotation located in the front or back of the plane grating with wavelength scanning. The outgoing beam from the monochromator goes through the fixed exit slit and has same beam direction regardless of the scanning wavelength. The combination of properly designed motions of the plane mirror and novel varied-spacing parameters of the inventive plane grating corrects the aberrations and focuses the monochromatic spectral image on the exit slit, enabling measurements at high spectral resolution. 10 figs.

  16. High resolution spectroscopy of ultracool M dwarfs

    E-Print Network [OSTI]

    I. Neill Reid; J. Davy Kirkpatrick; J. Liebert; J. E. Gizis; C. C. Dahn; D. G. Monet

    2002-04-17T23:59:59.000Z

    (abridged) We present high-resolution echelle spectroscopy of a photometricaly-selected sample if thirty-nine dwarfs with spectral types between M6.5 and L0.5. Two stars, 2MASSI 0253202+271333 and 2MASSW 0952219-192431, are double-lined spectroscopic binaries. We have used our observations to search for Li I 6708 A absorption, characteristic of sub-stellar mass; estimate the level of chromospheric activity through measurement of H-alpha emission fluxes; measure rotational velocities via line broadening; and determine radial velocities and Galactic space motions. Two dwarfs have strong lithium absorption, the previously-known brown dwarf, LP 944-20, and 2MASSI J0335020+234235, which we identify as a probable 0.06 M_sun brown dwarf, age ~1 Gyr. We have investigated the prospect of using the observed frequency of lithium absorption amongst ultracool M dwarfs (M7 to M9.5) as a probe of the initial mass function. The available observations are difficult to reconcile with Salpeter-like power-law mass functions (alpha > 2) for masses below 0.1M_Sun. A comparison between the rotational velocities and -alpha fluxes shows no evidence for significant correlation. Velocity dispersions are significantly lower than those measured for nearby M dwarfs, but show remarkable similarity to results for earlier-type emission-line (dMe) dwarfs. The latter are generally assigned ages of less than ~3 Gyrs.

  17. High vertical resolution crosswell seismic imaging

    DOE Patents [OSTI]

    Lazaratos, Spyridon K. (Houston, TX)

    1999-12-07T23:59:59.000Z

    A method for producing high vertical resolution seismic images from crosswell data is disclosed. In accordance with one aspect of the disclosure, a set of vertically spaced, generally horizontally extending continuous layers and associated nodes are defined within a region between two boreholes. The specific number of nodes is selected such that the value of a particular characteristic of the subterranean region at each of the nodes is one which can be determined from the seismic data. Once values are established at the nodes, values of the particular characteristic are assigned to positions between the node points of each layer based on the values at node within that layer and without regard to the values at node points within any other layer. A seismic map is produced using the node values and the assigned values therebetween. In accordance with another aspect of the disclosure, an approximate model of the region is established using direct arrival traveltime data. Thereafter, the approximate model is adjusted using reflected arrival data. In accordance with still another aspect of the disclosure, correction is provided for well deviation. An associated technique which provides improvements in ray tracing is also disclosed.

  18. A High-Resolution Global Climate Simulation

    SciTech Connect (OSTI)

    Duffy, P B

    2001-01-23T23:59:59.000Z

    A major factor limiting the quality and usefulness of global climate models is the coarse spatial resolution of these models. Global climate models today are typically run at resolutions of {approx}300 km (or even coarser) meaning that the smallest features represented are 300 km across. As Figure 1 shows, this resolution does not allow adequate representation of small or even large topographic features (e.g. the Sierra Nevada mountains). As a result of this and other problems, coarse-resolution global models do not come close to accurately simulating climate on regional spatial scales (e.g. within California). Results on continental and larger sales are much more realistic. An important consequence of this inability to simulate regional climate is that global climate model results cannot be used as the basis of assessments of potential societal impacts of climate change (e.g. effects on agriculture in the Central Valley, on management of water resources, etc.).

  19. Mexico City Aerosol Analysis during MILAGRO using High Resolution...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2: Mexico City Aerosol Analysis during MILAGRO using High Resolution Aerosol Mass Spectrometry at the Urban Supersite (T0). Part 2: Abstract: Submicron aerosol was analyzed during...

  20. Mexico City Aerosol Analysis during MILAGRO using High Resolution...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    1: Mexico City Aerosol Analysis during MILAGRO using High Resolution Aerosol Mass Spectrometry at the Urban Supersite (T0). Part 1: Abstract: Submicron aerosol was analyzed during...

  1. An Automated Platform for High-Resolution Tissue Imaging Using...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    entire image is acquired. The performance of the system is demonstrated by imaging rat brain tissue sections. High resolution mass analysis combined with MSMS experiments enabled...

  2. High-Resolution Electrospray Ionization Mass Spectrometry Analysis...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Mass Spectrometry Analysis of Water- Soluble Organic Aerosols Collected with a Particle High-Resolution Electrospray Ionization Mass Spectrometry Analysis of Water- Soluble Organic...

  3. Merging High Resolution Geophysical and Geochemical Surveys to...

    Open Energy Info (EERE)

    Buttes, Oregon Geothermal Project Jump to: navigation, search Last modified on July 22, 2011. Project Title Merging High Resolution Geophysical and Geochemical Surveys to Reduce...

  4. High-Resolution Desorption Electrospray Ionization Mass Spectrometry...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    between different mechanisms of chemical aging. Citation: Laskin J, A Laskin, PJ Roach, GW Slysz, GA Anderson, S Nizkorodov, DL Bones, and L Nguyen.2010."High-Resolution...

  5. High-Resolution Differential Ion Mobility Separations Using Helium...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Helium-Rich Gases. High-Resolution Differential Ion Mobility Separations Using Helium-Rich Gases. Abstract: Analyses of complex mixtures and characterization of ions increasingly...

  6. Merging high resolution geophysical and geochemical surveys to...

    Broader source: Energy.gov (indexed) [DOE]

    Merging high resolution geophysical and geochemical surveys to reduce exploration risk at Glass Buttes, Oregon Patrick Walsh Ormat Nevada Inc. Innovative technologies May 19, 2010...

  7. High resolution, high rate x-ray spectrometer

    DOE Patents [OSTI]

    Goulding, F.S.; Landis, D.A.

    1983-07-14T23:59:59.000Z

    It is an object of the invention to provide a pulse processing system for use with detected signals of a wide dynamic range which is capable of very high counting rates, with high throughput, with excellent energy resolution and a high signal-to-noise ratio. It is a further object to provide a pulse processing system wherein the fast channel resolving time is quite short and substantially independent of the energy of the detected signals. Another object is to provide a pulse processing system having a pile-up rejector circuit which will allow the maximum number of non-interfering pulses to be passed to the output. It is also an object of the invention to provide new methods for generating substantially symmetrically triangular pulses for use in both the main and fast channels of a pulse processing system.

  8. Construction and Evaluation of a High Spatial Resolution Wavefront Sensor

    E-Print Network [OSTI]

    Construction and Evaluation of a High Spatial Resolution Wavefront Sensor MARTIN BUSCHBECK Bachelor.3. Analysis program 3 Evaluation of the Hartmann-Shack sensor 3.1 Calibration of the sensor 3.1.1 Reference eyes. In this thesis a high spatial resolution Hartmann-Shack wavefront sensor, which allows the study

  9. assays high resolution: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Malbet 1995-09-14 31 High-resolution x-ray telescopes CERN Preprints Summary: High-energy astrophysics is a relatively young scientific field, made possible by space-borne...

  10. analysing high resolution: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Malbet 1995-09-14 34 High-resolution x-ray telescopes CERN Preprints Summary: High-energy astrophysics is a relatively young scientific field, made possible by space-borne...

  11. Exploring electronic structure through high-resolution hard x...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Laboratory Modern high brilliance beamlines coupled with recent advances in hard-x-ray optics are establishing high-resolution hard x-ray spectroscopies as a powerful analytical...

  12. Temporal variations of solar rotation rate at high latitudes

    E-Print Network [OSTI]

    H. M. Antia; Sarbani Basu

    2001-08-14T23:59:59.000Z

    Frequency splitting coefficients from Global Oscillation Network Group (GONG) and Michelson Doppler Imager (MDI) observations covering the period 1995--2001 are used to study temporal variations in the solar rotation rate at high latitudes. The torsional oscillation pattern in the Sun is known to penetrate to a depth of about $0.1R_\\odot$ with alternate bands of faster and slower rotating plasma. At lower latitudes the bands move towards equator with time. At higher latitudes, however, the bands appear to move towards the poles. This is similar to the observed pole-ward movement of large scale magnetic fields at high latitudes. This also supports theoretical results of pole-ward moving bands at high latitudes in some mean field dynamo models. The polar rotation rate is found to decrease between 1995 and 1999 after which it has started increasing.

  13. A high spatial resolution Stokes polarimeter for motional Stark effect imaging

    SciTech Connect (OSTI)

    Thorman, Alex; Michael, Clive; Howard, John [Plasma Research Laboratory, Research School of Physics and Engineering, Australian National University, Canberra ACT 0200 (Australia)

    2013-06-15T23:59:59.000Z

    We describe an enhanced temporally switched interfero-polarimeter that has been successfully deployed for high spatial resolution motional Stark effect imaging on the KSTAR superconducting tokamak. The system utilizes dual switching ferroelectric liquid crystal waveplates to image the full Stokes vector of elliptically polarized and Doppler-shifted Stark-Zeeman Balmer-alpha emission from high energy neutral beams injected into the magnetized plasma. We describe the optical system and compare its performance against a Mueller matrix model that takes account of non-ideal performance of the switching ferro-electric liquid crystal waveplates and other polarizing components.

  14. High resolution linkage and association study of quantitative trait loci

    E-Print Network [OSTI]

    Jung, Jeesun

    2005-11-01T23:59:59.000Z

    ) of complex human disease. For many complex diseases, quantitative phenotype values contain more information than dichotomous traits do. Much research has been done on conducting high resolution mapping using information of linkage and linkage disequilibrium...

  15. High resolution linkage and association study of quantitative trait loci 

    E-Print Network [OSTI]

    Jung, Jeesun

    2005-11-01T23:59:59.000Z

    As a large number of single nucleotide polymorphisms (SNPs) and microsatellite markers are available, high resolution mapping employing multiple markers or multiple allele markers is an important step to identify quantitative ...

  16. Technologies and R&D for a High Resolution Cavity BPM for the CLIC Main Beam

    E-Print Network [OSTI]

    Towler, J R; Soby, L; Wendt, M; Boogert, S T; Cullinan, F J; Lyapin, A

    2013-01-01T23:59:59.000Z

    The Main Beam (MB) linac of the Compact Linear Collider (CLIC) requires a beam orbit measurement system with high spatial (50 nm) and high temporal resolution (50 ns) to resolve the beam position within the 156 ns long bunch train, traveling on an energy-chirped, minimum dispersive trajectory. A 15 GHz prototype cavity BPM has been commissioned in the probe beam-line of the CTF3 CLIC Test Facility. We discuss performance and technical details of this prototype installation, including the 15 GHz analogue downconverter, the data acquisition and the control electronics and software. An R&D outlook is given for the next steps, which requires a system of 3 cavity BPMs to investigate the full resolution potential.

  17. Performance of a High Resolution Cavity Beam Position Monitor System

    SciTech Connect (OSTI)

    Walston, S; Boogert, S; Chung, C; Fitsos, P; Frisch, J; Gronberg, J; Hayano, H; Honda, Y; Kolomensky, Y; Lyapin, A; Malton, S; May, J; McCormick, D; Meller, R; Miller, D; Orimoto, T; Ross, M; Slater, M; Smith, S; Smith, T; Terunuma, N; Thomson, M; Urakawa, J; Vogel, V; Ward, D; White, G

    2006-12-18T23:59:59.000Z

    It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than one nanometer. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 {micro}rad over a dynamic range of approximately {+-} 20 {micro}m.

  18. Performance of a High Resolution Cavity Beam Position Monitor System

    SciTech Connect (OSTI)

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Joe; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Honda, Yosuke; Kolomensky, Yury; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David John; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; /Fermilab /UC,

    2007-06-08T23:59:59.000Z

    It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than one nanometer. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 {mu}rad over a dynamic range of approximately {+-} 20 {mu}m.

  19. High Resolution Muon Computed Tomography at Neutrino Beam Facilities

    E-Print Network [OSTI]

    Suerfu, Burkhant

    2015-01-01T23:59:59.000Z

    X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pio...

  20. High resolution amorphous silicon radiation detectors

    DOE Patents [OSTI]

    Street, R.A.; Kaplan, S.N.; Perez-Mendez, V.

    1992-05-26T23:59:59.000Z

    A radiation detector employing amorphous Si:H cells in an array with each detector cell having at least three contiguous layers (n-type, intrinsic, p-type), positioned between two electrodes to which a bias voltage is applied. An energy conversion layer atop the silicon cells intercepts incident radiation and converts radiation energy to light energy of a wavelength to which the silicon cells are responsive. A read-out device, positioned proximate to each detector element in an array allows each such element to be interrogated independently to determine whether radiation has been detected in that cell. The energy conversion material may be a layer of luminescent material having a columnar structure. In one embodiment a column of luminescent material detects the passage therethrough of radiation to be detected and directs a light beam signal to an adjacent a-Si:H film so that detection may be confined to one or more such cells in the array. One or both electrodes may have a comb structure, and the teeth of each electrode comb may be interdigitated for capacitance reduction. The amorphous Si:H film may be replaced by an amorphous Si:Ge:H film in which up to 40 percent of the amorphous material is Ge. Two dimensional arrays may be used in X-ray imaging, CT scanning, crystallography, high energy physics beam tracking, nuclear medicine cameras and autoradiography. 18 figs.

  1. High resolution amorphous silicon radiation detectors

    DOE Patents [OSTI]

    Street, Robert A. (Palo Alto, CA); Kaplan, Selig N. (El Cerrito, CA); Perez-Mendez, Victor (Berkeley, CA)

    1992-01-01T23:59:59.000Z

    A radiation detector employing amorphous Si:H cells in an array with each detector cell having at least three contiguous layers (n type, intrinsic, p type), positioned between two electrodes to which a bias voltage is applied. An energy conversion layer atop the silicon cells intercepts incident radiation and converts radiation energy to light energy of a wavelength to which the silicon cells are responsive. A read-out device, positioned proximate to each detector element in an array allows each such element to be interrogated independently to determine whether radiation has been detected in that cell. The energy conversion material may be a layer of luminescent material having a columnar structure. In one embodiment a column of luminescent material detects the passage therethrough of radiation to be detected and directs a light beam signal to an adjacent a-Si:H film so that detection may be confined to one or more such cells in the array. One or both electrodes may have a comb structure, and the teeth of each electrode comb may be interdigitated for capacitance reduction. The amorphous Si:H film may be replaced by an amorphous Si:Ge:H film in which up to 40 percent of the amorphous material is Ge. Two dimensional arrays may be used in X-ray imaging, CT scanning, crystallography, high energy physics beam tracking, nuclear medicine cameras and autoradiography.

  2. Isotope specific resolution recovery image reconstruction in high resolution PET imaging

    SciTech Connect (OSTI)

    Kotasidis, Fotis A. [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva, Switzerland and Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, M20 3LJ, Manchester (United Kingdom)] [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva, Switzerland and Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, M20 3LJ, Manchester (United Kingdom); Angelis, Georgios I. [Faculty of Health Sciences, Brain and Mind Research Institute, University of Sydney, NSW 2006, Sydney (Australia)] [Faculty of Health Sciences, Brain and Mind Research Institute, University of Sydney, NSW 2006, Sydney (Australia); Anton-Rodriguez, Jose; Matthews, Julian C. [Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, Manchester M20 3LJ (United Kingdom)] [Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, Manchester M20 3LJ (United Kingdom); Reader, Andrew J. [Montreal Neurological Institute, McGill University, Montreal QC H3A 2B4, Canada and Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King's College London, St. Thomas’ Hospital, London SE1 7EH (United Kingdom)] [Montreal Neurological Institute, McGill University, Montreal QC H3A 2B4, Canada and Department of Biomedical Engineering, Division of Imaging Sciences and Biomedical Engineering, King's College London, St. Thomas’ Hospital, London SE1 7EH (United Kingdom); Zaidi, Habib [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva (Switzerland) [Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva (Switzerland); Geneva Neuroscience Centre, Geneva University, CH-1205 Geneva (Switzerland); Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, PO Box 30 001, Groningen 9700 RB (Netherlands)

    2014-05-15T23:59:59.000Z

    Purpose: Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measurements. As such, non-optimal PSF models that do not correspond to those needed for the data to be reconstructed are used within resolution modeling (RM) image reconstruction, usually underestimating the true PSF owing to the difference in positron range. In high resolution brain and preclinical imaging, this effect is of particular importance since the PSFs become more positron range limited and isotope-specific PSFs can help maximize the performance benefit from using resolution recovery image reconstruction algorithms. Methods: In this work, the authors used a printing technique to simultaneously measure multiple point sources on the High Resolution Research Tomograph (HRRT), and the authors demonstrated the feasibility of deriving isotope-dependent system matrices from fluorine-18 and carbon-11 point sources. Furthermore, the authors evaluated the impact of incorporating them within RM image reconstruction, using carbon-11 phantom and clinical datasets on the HRRT. Results: The results obtained using these two isotopes illustrate that even small differences in positron range can result in different PSF maps, leading to further improvements in contrast recovery when used in image reconstruction. The difference is more pronounced in the centre of the field-of-view where the full width at half maximum (FWHM) from the positron range has a larger contribution to the overall FWHM compared to the edge where the parallax error dominates the overall FWHM. Conclusions: Based on the proposed methodology, measured isotope-specific and spatially variant PSFs can be reliably derived and used for improved spatial resolution and variance performance in resolution recovery image reconstruction. The benefits are expected to be more substantial for more energetic positron emitting isotopes such as Oxygen-15 and Rubidium-82.

  3. Edinburgh Research Explorer High-resolution gene expression profiling for simultaneous

    E-Print Network [OSTI]

    Millar, Andrew J.

    Edinburgh Research Explorer High-resolution gene expression profiling for simultaneous kinetic, UH 2008, 'High-resolution gene expression profiling for simultaneous kinetic parameter analysis date: 16. Jun. 2014 #12;METHOD High-resolution gene expression profiling for simultaneous kinetic

  4. An Investigation of the Rotamers of Butadiene by High-Resolution...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Investigation of the Rotamers of Butadiene by High-Resolution Infrared Spectroscopy. An Investigation of the Rotamers of Butadiene by High-Resolution Infrared Spectroscopy....

  5. HIGH RESOLUTION SCANNING AUGER MICROSCOPIC INVESTIGATION OF INTERGRANULAR FRACTURE IN AS-QUENCHED Fe-12Mn

    E-Print Network [OSTI]

    Lee, H.J.

    2013-01-01T23:59:59.000Z

    contents in Fe-Mn alloys. Scanning electron fractographsTransactions HIGH RESOLUTION SCANNING AUGER MICROSCOPICof Califomia. HIGH RESOLUTION SCANNING AUGER MICROSCOPIC

  6. High Resolution Additive Patterning of Nanoparticles and Polymers Enabled by Vapor Permeable Polymer Templates

    E-Print Network [OSTI]

    Demko, Michael Thomas

    2012-01-01T23:59:59.000Z

    High Resolution Additive Patterning of Nanoparticles andHigh Resolution Additive Patterning of Nanoparticles andareas, and in a completely additive manner. In this work, a

  7. Development of Superconducting High-Resolution Gamma-Ray Spectrometers for Nuclear Safeguards

    E-Print Network [OSTI]

    Dreyer, Jonathan

    2012-01-01T23:59:59.000Z

    Counting 2.4.3 High-Resolution Gamma Spectrometry 2.5coincidence counting and gamma spectrometry system (CANEGA)High-Resolution Gamma Spectrometry Isotopic correlation

  8. High Resolution Backside Imaging and Thermography using a Numerical Aperture Increasing Lens

    E-Print Network [OSTI]

    High Resolution Backside Imaging and Thermography using a Numerical Aperture Increasing Lens M. S, representing the highest resolution subsurface thermography to date. Keywords: thermal imaging, high

  9. High Resolution Muon Computed Tomography at Neutrino Beam Facilities

    E-Print Network [OSTI]

    Burkhant Suerfu; Christopher G. Tully

    2015-01-28T23:59:59.000Z

    X-ray computed tomography (CT) has an indispensable role in constructing 3D images of objects made from light materials. However, limited by absorption coefficients, X-rays cannot deeply penetrate materials such as copper and lead. Here we show via simulation that muon beams can provide high resolution tomographic images of dense objects and of structures within the interior of dense objects. The effects of resolution broadening from multiple scattering diminish with increasing muon momentum. As the momentum of the muon increases, the contrast of the image goes down and therefore requires higher resolution in the muon spectrometer to resolve the image. The variance of the measured muon momentum reaches a minimum and then increases with increasing muon momentum. The impact of the increase in variance is to require a higher integrated muon flux to reduce fluctuations. The flux requirements and level of contrast needed for high resolution muon computed tomography are well matched to the muons produced in the pion decay pipe at a neutrino beam facility and what can be achieved for momentum resolution in a muon spectrometer. Such an imaging system can be applied in archaeology, art history, engineering, material identification and whenever there is a need to image inside a transportable object constructed of dense materials.

  10. High-Resolution Simulations of Coal Injection in A Gasifier

    SciTech Connect (OSTI)

    Li, Tingwen [National Energy Technology Laboratory (NETL); Gel, Aytekin [Aeolus Research Inc.; Syamlal, M [National Energy Technology Laboratory (NETL); Guenther, Chris [National Energy Technology Laboratory (NETL); Pannala, Sreekanth [ORNL

    2010-01-01T23:59:59.000Z

    This study demonstrates an approach to effectively combine high- and low-resolution simulations for design studies of industrial coal gasifier. The flow-field data from a 10 million cell full-scale simulation of a commercial-scale gasifier were used to construct a reduced configuration to economically study the coal injection in detail. High-resolution numerical simulations of the coal injection were performed using the open-source code MFIX running on a high performance computing system. Effects of grid resolution and numerical discretization scheme on the predicted behavior of coal injection and gasification kinetics were analyzed. Pronounced differences were predicted in the devolatilization and steam gasification rates because of different discretization schemes, implying that a high-order numerical scheme is required to predict well the unsteady gasification process on an adequately resolved grid. Computational costs for simulations of varying resolutions are presented to illustrate the trade-off between the accuracy of solution and the time-to-solution, an important consideration when engineering simulations are used for the design of commercial-scale units.

  11. High-resolution speech signal reconstruction in Wireless Sensor Networks

    E-Print Network [OSTI]

    Gutierrez-Osuna, Ricardo

    High-resolution speech signal reconstruction in Wireless Sensor Networks Andria Pazarloglou, Radu With the recent growth of Wireless Sensor Networks (WSNs), many advanced application areas have received sig, rgutier}@cs.tamu.edu Abstract--Data streaming is an emerging class of applica- tions for sensor networks

  12. Greenland Observed at High Resolution by the Seasat Scatterometer

    E-Print Network [OSTI]

    Long, David G.

    Greenland Observed at High Resolution by the Seasat Scatterometer D.G. Long', P.J. Hardin2, and RA to SASS data for the study of Greenland's ice sheet. We present a time series of the radar backscatter images over Greenland covering the time period July-September 1978. The images provide an island

  13. High-Resolution Computed Tomography Study of the Cranium of

    E-Print Network [OSTI]

    Allman, John M.

    High-Resolution Computed Tomography Study of the Cranium of a Fossil Anthropoid Primate of these characteristics may have important implications for brain evolution. Here computed tomography is used to examine in the evolutionary development of anthropoids did these characteristics evolve? We recently used X-ray computed

  14. A High-Resolution Single Nucleotide Polymorphism Genetic Map

    E-Print Network [OSTI]

    Nachman, Michael

    A High-Resolution Single Nucleotide Polymorphism Genetic Map of the Mouse Genome Sagiv Shifman1 humans. Using more than 10,000 single nucleotide polymorphisms evenly spaced across the mouse genome, we nucleotide polymorphism genetic map of the mouse genome. PLoS Biol 4(12): e395. DOI: 10.1371/journal

  15. X-ray pulse preserving single-shot optical cross-correlation method for improved experimental temporal resolution

    SciTech Connect (OSTI)

    Beye, M. [SIMES, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, 12489 Berlin (Germany); Krupin, O. [LCLS, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); European XFEL GmbH, 22607 Hamburg (Germany); Hays, G.; Jong, S. de; Lee, S.; Coffee, R.; Holmes, M. R.; Fry, A. R.; White, W. E.; Bostedt, C.; Schlotter, W. F. [LCLS, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Reid, A. H. [SIMES, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Radboud University Nijmegen, Institute for Molecules and Materials, 6525 AJ Nijmegen (Netherlands); Rupp, D. [Technische Universitaet Berlin, 10623 Berlin (Germany); LCLS, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Lee, W.-S.; Scherz, A. O. [SIMES, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Chuang, Y.-D. [Advanced Light Source, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Cryan, J. P.; Glownia, J. M. [PULSE, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); LCLS, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Foehlisch, A. [Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, 12489 Berlin (Germany); Durr, H. A. [SIMES, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); PULSE, SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States)

    2012-03-19T23:59:59.000Z

    We measured the relative arrival time between an optical pulse and a soft x-ray pulse from a free-electron laser. This femtosecond cross-correlation measurement was achieved by observing the change in optical reflectivity induced through the absorption of a fraction of the x-ray pulse. The main x-ray pulse energy remained available for an independent pump-probe experiment where the sample may be opaque to soft x-rays. The method was employed to correct the two-pulse delay data from a canonical pump-probe experiment and demonstrate 130 {+-} 20 fs (FWHM) temporal resolution. We further analyze possible timing jitter sources and point to future improvements.

  16. Broadband high resolution X-ray spectral analyzer

    DOE Patents [OSTI]

    Silver, E.H.; Legros, M.; Madden, N.W.; Goulding, F.; Landis, D.

    1998-07-07T23:59:59.000Z

    A broad bandwidth high resolution X-ray fluorescence spectrometer has a performance that is superior in many ways to those currently available. It consists of an array of 4 large area microcalorimeters with 95% quantum efficiency at 6 keV and it produces X-ray spectra between 0.2 keV and 7 keV with an energy resolution of 7 to 10 eV. The resolution is obtained at input count rates per array element of 10 to 50 Hz in real-time, with analog pulse processing and thermal pile-up rejection. This performance cannot be matched by currently available X-ray spectrometers. The detectors are incorporated into a compact and portable cryogenic refrigerator system that is ready for use in many analytical spectroscopy applications as a tool for X-ray microanalysis or in research applications such as laboratory and astrophysical X-ray and particle spectroscopy. 6 figs.

  17. Broadband high resolution X-ray spectral analyzer

    DOE Patents [OSTI]

    Silver, Eric H. (Berkeley, CA); Legros, Mark (Berkeley, CA); Madden, Norm W. (Livermore, CA); Goulding, Fred (Lafayette, CA); Landis, Don (Pinole, CA)

    1998-01-01T23:59:59.000Z

    A broad bandwidth high resolution x-ray fluorescence spectrometer has a performance that is superior in many ways to those currently available. It consists of an array of 4 large area microcalorimeters with 95% quantum efficiency at 6 keV and it produces x-ray spectra between 0.2 keV and 7 keV with an energy resolution of 7 to 10 eV. The resolution is obtained at input count rates per array element of 10 to 50 Hz in real-time, with analog pulse processing and thermal pile-up rejection. This performance cannot be matched by currently available x-ray spectrometers. The detectors are incorporated into a compact and portable cryogenic refrigerator system that is ready for use in many analytical spectroscopy applications as a tool for x-ray microanalysis or in research applications such as laboratory and astrophysical x-ray and particle spectroscopy.

  18. High-resolution ionization detector and array of such detectors

    DOE Patents [OSTI]

    McGregor, Douglas S. (Ypsilanti, MI); Rojeski, Ronald A. (Pleasanton, CA)

    2001-01-16T23:59:59.000Z

    A high-resolution ionization detector and an array of such detectors are described which utilize a reference pattern of conductive or semiconductive material to form interaction, pervious and measurement regions in an ionization substrate of, for example, CdZnTe material. The ionization detector is a room temperature semiconductor radiation detector. Various geometries of such a detector and an array of such detectors produce room temperature operated gamma ray spectrometers with relatively high resolution. For example, a 1 cm.sup.3 detector is capable of measuring .sup.137 Cs 662 keV gamma rays with room temperature energy resolution approaching 2% at FWHM. Two major types of such detectors include a parallel strip semiconductor Frisch grid detector and the geometrically weighted trapezoid prism semiconductor Frisch grid detector. The geometrically weighted detector records room temperature (24.degree. C.) energy resolutions of 2.68% FWHM for .sup.137 Cs 662 keV gamma rays and 2.45% FWHM for .sup.60 Co 1.332 MeV gamma rays. The detectors perform well without any electronic pulse rejection, correction or compensation techniques. The devices operate at room temperature with simple commercially available NIM bin electronics and do not require special preamplifiers or cooling stages for good spectroscopic results.

  19. High resolution reservoir geological modelling using outcrop information

    SciTech Connect (OSTI)

    Zhang Changmin; Lin Kexiang; Liu Huaibo [Jianghan Petroleum Institute, Hubei (China)] [and others

    1997-08-01T23:59:59.000Z

    This is China`s first case study of high resolution reservoir geological modelling using outcrop information. The key of the modelling process is to build a prototype model and using the model as a geological knowledge bank. Outcrop information used in geological modelling including seven aspects: (1) Determining the reservoir framework pattern by sedimentary depositional system and facies analysis; (2) Horizontal correlation based on the lower and higher stand duration of the paleo-lake level; (3) Determining the model`s direction based on the paleocurrent statistics; (4) Estimating the sandbody communication by photomosaic and profiles; (6) Estimating reservoir properties distribution within sandbody by lithofacies analysis; and (7) Building the reservoir model in sandbody scale by architectural element analysis and 3-D sampling. A high resolution reservoir geological model of Youshashan oil field has been built by using this method.

  20. HIGH SPATIAL RESOLUTION OBSERVATIONS OF LOOPS IN THE SOLAR CORONA

    SciTech Connect (OSTI)

    Brooks, David H.; Ugarte-Urra, Ignacio [College of Science, George Mason University, 4400 University Drive, Fairfax, VA 22030 (United States); Warren, Harry P. [Space Science Division, Naval Research Laboratory, Washington, DC 20375 (United States); Winebarger, Amy R. [NASA Marshall Space Flight Center, ZP 13, Huntsville, AL 35812 (United States)

    2013-08-01T23:59:59.000Z

    Understanding how the solar corona is structured is of fundamental importance to determine how the Sun's upper atmosphere is heated to high temperatures. Recent spectroscopic studies have suggested that an instrument with a spatial resolution of 200 km or better is necessary to resolve coronal loops. The High Resolution Coronal Imager (Hi-C) achieved this performance on a rocket flight in 2012 July. We use Hi-C data to measure the Gaussian widths of 91 loops observed in the solar corona and find a distribution that peaks at about 270 km. We also use Atmospheric Imaging Assembly data for a subset of these loops and find temperature distributions that are generally very narrow. These observations provide further evidence that loops in the solar corona are often structured at a scale of several hundred kilometers, well above the spatial scale of many proposed physical mechanisms.

  1. Turbine component casting core with high resolution region

    DOE Patents [OSTI]

    Kamel, Ahmed; Merrill, Gary B.

    2014-08-26T23:59:59.000Z

    A hollow turbine engine component with complex internal features can include a first region and a second, high resolution region. The first region can be defined by a first ceramic core piece formed by any conventional process, such as by injection molding or transfer molding. The second region can be defined by a second ceramic core piece formed separately by a method effective to produce high resolution features, such as tomo lithographic molding. The first core piece and the second core piece can be joined by interlocking engagement that once subjected to an intermediate thermal heat treatment process thermally deform to form a three dimensional interlocking joint between the first and second core pieces by allowing thermal creep to irreversibly interlock the first and second core pieces together such that the joint becomes physically locked together providing joint stability through thermal processing.

  2. A high resolution cavity BPM for the CLIC Test Facility

    E-Print Network [OSTI]

    Chritin, N; Soby, L; Lunin, A; Solyak, N; Wendt, M; Yakovlev, V

    2012-01-01T23:59:59.000Z

    In frame of the development of a high resolution BPM system for the CLIC Main Linac we present the design of a cavity BPM prototype. It consists of a waveguide loaded dipole mode resonator and a monopole mode reference cavity, both operating at 15 GHz, to be compatible with the bunch frequencies at the CLIC Test Facility. Requirements, design concept, numerical analysis, and practical considerations are discussed.

  3. High energy resolution, high angular acceptance crystal monochromator

    DOE Patents [OSTI]

    Alp, Ercan E. (Bolingbrook, IL); Mooney, Timothy M. (Westmont, IL); Toellner, Thomas (Green Bay, WI)

    1996-06-04T23:59:59.000Z

    A 4-bounce dispersive crystal monochromator reduces the bandpass of synchrotron radiation to a 10-50 meV range without sacrificing angular acceptance. The monochromator includes the combination of an asymmetrical channel-cut single crystal of lower order reflection and a symmetrical channel-cut single crystal of higher order reflection in a nested geometric configuration. In the disclosed embodiment, a highly asymmetrically cut (.alpha.=20) outer silicon crystal (4 2 2) with low order reflection is combined with a symmetrically cut inner silicon crystal (10 6 4) with high order reflection to condition a hard x-ray component (5-30 keV) of synchrotron radiation down to the .mu.eV-neV level. Each of the crystals is coupled to the combination of a positioning inchworm and angle encoder via a respective rotation stage for accurate relative positioning of the crystals and precise energy tuning of the monochromator.

  4. Compact High-Velocity Clouds at High Resolution

    E-Print Network [OSTI]

    W. B. Burton; Robert Braun

    1999-12-22T23:59:59.000Z

    Six examples of the compact, isolated high-velocity clouds catalogued by Braun & Burton (1999) and identified with a dynamically cold ensemble of primitive objects falling towards the barycenter of the Local Group have been imaged with the Westerbork Synthesis Radio Telescope; an additional ten have been imaged with the Arecibo telescope. The imaging reveals a characteristic core/halo morphology: one or several cores of cool, relatively high-column-density material, are embedded in an extended halo of warmer, lower-density material. Several of the cores show kinematic gradients consistent with rotation; these CHVCs are evidently rotationally supported and dark-matter dominated. The imaging data allows several independent estimates of the distances to these objects, which lie in the range 0.3 to 1.0 Mpc. The CHVC properties resemble what might be expected from very dark dwarf irregular galaxies.

  5. High energy resolution, high angular acceptance crystal monochromator

    DOE Patents [OSTI]

    Alp, E.E.; Mooney, T.M.; Toellner, T.

    1996-06-04T23:59:59.000Z

    A 4-bounce dispersive crystal monochromator reduces the bandpass of synchrotron radiation to a 10-50 meV range without sacrificing angular acceptance. The monochromator includes the combination of an asymmetrical channel-cut single crystal of lower order reflection and a symmetrical channel-cut single crystal of higher order reflection in a nested geometric configuration. In the disclosed embodiment, a highly asymmetrically cut ({alpha}=20) outer silicon crystal (4 2 2) with low order reflection is combined with a symmetrically cut inner silicon crystal (10 6 4) with high order reflection to condition a hard x-ray component (5--30 keV) of synchrotron radiation down to the {micro}eV-neV level. Each of the crystals is coupled to the combination of a positioning inchworm and angle encoder via a respective rotation stage for accurate relative positioning of the crystals and precise energy tuning of the monochromator. 7 figs.

  6. High-resolution imaging of compact high-velocity clouds

    E-Print Network [OSTI]

    Robert Braun; Butler Burton

    1999-12-20T23:59:59.000Z

    Six examples of the compact, isolated high-velocity HI clouds (CHVCs) identified by Braun and Burton (1999) have been imaged with the WSRT. The 65 confirmed objects in this class define a dynamically cold system, with a global minimum for the velocity dispersion of only 70 km/s, found in the Local Group Standard of Rest, while in-falling at 100 km/s toward the LG barycenter. These objects have a characteristic morphology, in which several compact cores are embedded in a diffuse halo. The compact cores typically account for 40% of the HI line flux while covering some 15% of the source area. The cores are the cool condensed phase of HI, the CNM, with temp. near 100 K, while the halos appear to be a shielding column of warm diffuse HI, the WNM, with temp. near 8000 K. We detect a core with one of the narrowest HI emission lines ever observed, with intrinsic FWHM of 2 km/s and 75 K brightness. From a comparison of column and volume densities we derive a distance in the range 0.5 to 1 Mpc. We determine a metallicity for this same object of 0.04 to 0.07 solar. Comparably high distances are implied by demanding the stability of objects with multiple cores, which show relative velocities as large as 70 km/s on 30 arcmin scales. Many compact cores show systematic velocity gradients along the major axis of their elliptical extent which are consistent with circular rotation. Several of the derived rotation curves are well-fit by Navarro, Frenk, and White (1997) cold dark matter profiles. These kinematic signatures imply a high dark-to-visible mass ratio of 10-50, for D=0.7Mpc, which scales as 1/D. The implied dark matter halos dominate the mass volume density within the central 2 kpc (10 arcmin) of each source, providing a sufficent hydrostatic pressure to allow local CNM condensation. (abridged)

  7. ON THE IMPACT OF SUPER RESOLUTION WSR-88D DOPPLER RADAR DATA ASSIMILATION ON HIGH RESOLUTION NUMERICAL MODEL FORECASTS

    SciTech Connect (OSTI)

    Chiswell, S

    2009-01-11T23:59:59.000Z

    Assimilation of radar velocity and precipitation fields into high-resolution model simulations can improve precipitation forecasts with decreased 'spin-up' time and improve short-term simulation of boundary layer winds (Benjamin, 2004 & 2007; Xiao, 2008) which is critical to improving plume transport forecasts. Accurate description of wind and turbulence fields is essential to useful atmospheric transport and dispersion results, and any improvement in the accuracy of these fields will make consequence assessment more valuable during both routine operation as well as potential emergency situations. During 2008, the United States National Weather Service (NWS) radars implemented a significant upgrade which increased the real-time level II data resolution to 8 times their previous 'legacy' resolution, from 1 km range gate and 1.0 degree azimuthal resolution to 'super resolution' 250 m range gate and 0.5 degree azimuthal resolution (Fig 1). These radar observations provide reflectivity, velocity and returned power spectra measurements at a range of up to 300 km (460 km for reflectivity) at a frequency of 4-5 minutes and yield up to 13.5 million point observations per level in super-resolution mode. The migration of National Weather Service (NWS) WSR-88D radars to super resolution is expected to improve warning lead times by detecting small scale features sooner with increased reliability; however, current operational mesoscale model domains utilize grid spacing several times larger than the legacy data resolution, and therefore the added resolution of radar data is not fully exploited. The assimilation of super resolution reflectivity and velocity data into high resolution numerical weather model forecasts where grid spacing is comparable to the radar data resolution is investigated here to determine the impact of the improved data resolution on model predictions.

  8. High-resolution NMR process analyzer for oxygenates in gasoline

    SciTech Connect (OSTI)

    Skloss, T.W.; Kim, A.J.; Haw, J.F. (Texas A M Univ., College Station, TX (United States))

    1994-02-15T23:59:59.000Z

    We report a high-resolution 42-MHz[sup 1]HFT-NMR instrument that is suitable for use as a process analyzer and demonstrate its use in the determination of methyl tert-butyl ether (MTBE) in a flowing stream of gasoline. This spectrometer is based on a 55-kg permanent magnet with essentially no fringe field. A spectral resolution of 3 Hz was typically obtained for spinning samples, and this performance was only slightly degraded with flowing samples. We report a procedure for magnet drift compensation using a software procedure rather than a field-frequency lock channel. This procedure allowed signal averaging without loss of resolution. Regulatory changes to be implemented in the near future have created a need for the development of methods for the determination of MTBE and other oxygenates in reformulated gasolines. Existing methods employing gas chromatography are not fast enough for process control of a gasoline blender and suffer from other limitations. This study demonstrates that process analysis NMR is well-suited to the determination of MTBE in a simulated gasoline blender. The detection limit of 0.5 vol % MTBE was obtained with a measurement time of 1 min. The absolute standard deviation of independent determinations was 0.17% when the MTBE concentration was 10%, a nominal value. Preliminary results also suggest that the method may be applicable to gasolines containing mixtures of oxygenate additives as well as the measurement of aromatic and olefinic hydrogens. 33 refs., 9 figs.

  9. Resolution of a High Performance Cavity Beam Position Monitor System

    SciTech Connect (OSTI)

    Walston, S; Chung, C; Fitsos, P; Gronberg, J; Ross, M; Khainovski, O; Kolomensky, Y; Loscutoff, P; Slater, M; Thomson, M; Ward, D; Boogert, S; Vogel, V; Meller, R; Lyapin, A; Malton, S; Miller, D; Frisch, J; Hinton, S; May, J; McCormick, D; Smith, S; Smith, T; White, G; Orimoto, T; Hayano, H; Honda, Y; Terunuma, N; Urakawa, J

    2005-09-12T23:59:59.000Z

    International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved - ideally using beam-based stability measurements. It has been estimated that RF cavity beam position monitors (BPMs) could provide position measurement resolutions of less than one nanometer and could form the basis of the desired beam-based stability measurement. We have developed a high resolution RF cavity BPM system. A triplet of these BPMs has been installed in the extraction line of the KEK Accelerator Test Facility (ATF) for testing with its ultra-low emittance beam. A metrology system for the three BPMs was recently installed. This system employed optical encoders to measure each BPM's position and orientation relative to a zero-coefficient of thermal expansion carbon fiber frame and has demonstrated that the three BPMs behave as a rigid-body to less than 5 nm. To date, we have demonstrated a BPM resolution of less than 20 nm over a dynamic range of +/- 20 microns.

  10. High-resolution SIMS depth profiling of nanolayers.

    SciTech Connect (OSTI)

    Baryshev, S. V.; Zinovev, A. V.; Tripa, C. E.; Pellin, M. J.; Peng, Q.; Elam, J. W.; Veryovkin, I. V. (Energy Systems); ( MSD)

    2012-10-15T23:59:59.000Z

    Although the fundamental physical limits for depth resolution of secondary ion mass spectrometry are well understood in theory, the experimental work to achieve and demonstrate them is still ongoing. We report results of high-resolution TOF SIMS (time-of-flight secondary ion mass spectrometry) depth profiling experiments on a nanolayered structure, a stack of 16 alternating MgO and ZnO {approx}5.5 nm layers grown on a Si substrate by atomic layer deposition. The measurements were performed using a newly developed approach implementing a low-energy direct current normally incident Ar{sup +} ion beam for ion milling (250 eV and 500 eV energy), in combination with a pulsed 5 keV Ar{sup +} ion beam at 60{sup o} incidence for TOF SIMS analysis. By this optimized arrangement, a noticeably improved version of the dual-beam (DB) approach to TOF SIMS depth profiling is introduced, which can be dubbed gentleDB. The mixing-roughness-information model was applied to detailed analysis of experimental results. It revealed that the gentleDB approach allows ultimate depth resolution by confining the ion beam mixing length to about two monolayers. This corresponds to the escape depth of secondary ions, the fundamental depth resolution limitation in SIMS. Other parameters deduced from the measured depth profiles indicated that a single layer thickness is equal to 6 nm so that the 'flat' layer thickness d is 3 nm and the interfacial roughness {sigma} is 1.5 nm, thus yielding d + 2{sigma} = 6 nm. We have demonstrated that gentleDB TOF SIMS depth profiling with noble gas ion beams is capable of revealing the structural features of a stack of nanolayers, resolving its original surface and estimating the roughness of interlayer interfaces, information which is difficult to obtain by traditional approaches.

  11. POWERWALL: International Workshop on Interactive, Ultra-High-Resolution Displays

    SciTech Connect (OSTI)

    Rooney, Chris; Endert, Alexander; Fekete, Jean-Daniel; Hornbaek, Kasper; North, Chris

    2013-04-27T23:59:59.000Z

    Ultra-high-resolution (Powerwall) displays are becoming increasingly popular due to the ever decreasing cost of hardware. As a result they are appearing more frequently in research institutes, and making the jump out of the lab and into industry. Due to the amount of work in this research area that has been published in CHI over the last few years, we felt that this confernece would be the ideal host for the first opportunity for both academics and practitioners in this field to get together.

  12. High-resolution radio observations of X-ray binaries

    E-Print Network [OSTI]

    James Miller-Jones

    2008-09-15T23:59:59.000Z

    I present an overview of important results obtained using high-resolution very long baseline interferometry (VLBI) observations of X-ray binary systems. These results derive from both astrometric observations and resolved imaging of sources, from black holes to neutron star and even white dwarf systems. I outline a number of upcoming developments in instrumentation, both new facilities and ongoing upgrades to existing VLBI instruments, and I conclude by identifying a number of important areas of investigation where VLBI will be crucial in advancing our understanding of X-ray binaries.

  13. Compact high resolution isobar separator for study of exotic decays

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power Administration would like submit the followingth Lomonosov1Compact high resolution isobar

  14. Analysis of the rotational structure in the high-resolution infrared...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    rotational structure in the high-resolution infrared spectra of cis,cis- and trans,trans-1,4-difluorobutadiene-1 Analysis of the rotational structure in the high-resolution...

  15. Analysis of the Rotational Structure in the High-Resolution Infrared...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Rotational Structure in the High-Resolution Infrared Spectrum of trans-Hexatriene-1-13C1; a Semiexperimental Analysis of the Rotational Structure in the High-Resolution Infrared...

  16. Final report: high resolution lensless 3D imaging of nanostructures with coherent x-rays

    SciTech Connect (OSTI)

    Jacobsen, Chris

    2014-12-07T23:59:59.000Z

    Final report on the project "High resolution lensless 3D imaging of nanostructures with coherent x-rays"

  17. High-level waste issues and resolutions document

    SciTech Connect (OSTI)

    Not Available

    1994-05-01T23:59:59.000Z

    The High-Level Waste (HLW) Issues and Resolutions Document recognizes US Department of Energy (DOE) complex-wide HLW issues and offers potential corrective actions for resolving these issues. Westinghouse Management and Operations (M&O) Contractors are effectively managing HLW for the Department of Energy at four sites: Idaho National Engineering Laboratory (INEL), Savannah River Site (SRS), West Valley Demonstration Project (WVDP), and Hanford Reservation. Each site is at varying stages of processing HLW into a more manageable form. This HLW Issues and Resolutions Document identifies five primary issues that must be resolved in order to reach the long-term objective of HLW repository disposal. As the current M&O contractor at DOE`s most difficult waste problem sites, Westinghouse recognizes that they have the responsibility to help solve some of the complexes` HLW problems in a cost effective manner by encouraging the M&Os to work together by sharing expertise, eliminating duplicate efforts, and sharing best practices. Pending an action plan, Westinghouse M&Os will take the initiative on those corrective actions identified as the responsibility of an M&O. This document captures issues important to the management of HLW. The proposed resolutions contained within this document set the framework for the M&Os and DOE work cooperatively to develop an action plan to solve some of the major complex-wide problems. Dialogue will continue between the M&Os, DOE, and other regulatory agencies to work jointly toward the goal of storing, treating, and immobilizing HLW for disposal in an environmentally sound, safe, and cost effective manner.

  18. High-resolution X-ray spectroscopy of Theta Car

    E-Print Network [OSTI]

    Yael Naze; Gregor Rauw

    2008-08-25T23:59:59.000Z

    Context : The peculiar hot star Theta Car in the open cluster IC2602 is a blue straggler as well as a single-line binary of short period (2.2d). Aims : Its high-energy properties are not well known, though X-rays can provide useful constraints on the energetic processes at work in binaries as well as in peculiar, single objects. Methods : We present the analysis of a 50ks exposure taken with the XMM-Newton observatory. It provides medium as well as high-resolution spectroscopy. Results : Our high-resolution spectroscopy analysis reveals a very soft spectrum with multiple temperature components (1--6MK) and an X-ray flux slightly below the `canonical' value (log[L_X(0.1-10.)/L_{BOL}] ~ -7). The X-ray lines appear surprisingly narrow and unshifted, reminiscent of those of beta Cru and tau Sco. Their relative intensities confirm the anomalous abundances detected in the optical domain (C strongly depleted, N strongly enriched, O slightly depleted). In addition, the X-ray data favor a slight depletion in neon and iron, but they are less conclusive for the magnesium abundance (solar-like?). While no significant changes occur during the XMM-Newton observation, variability in the X-ray domain is detected on the long-term range. The formation radius of the X-ray emission is loosely constrained to <5 R_sol, which allows for a range of models (wind-shock, corona, magnetic confinement,...) though not all of them can be reconciled with the softness of the spectrum and the narrowness of the lines.

  19. Towards wide-field high-resolution retinal imaging

    E-Print Network [OSTI]

    Kellerer, Aglae

    2015-01-01T23:59:59.000Z

    Adaptive optical correction is an efficient technique to obtain high-resolution images of the retinal surface. A main limitation of adaptive optical correction, however, is the small size of the corrected image. For medical purposes it is important to increase the size of the corrected images. This can be done through composite imaging, but a major difficulty is then the introduction of reconstruction artifacts. Another approach is multi-conjugate adaptive optics. MCAO comes in two flavors. The star- oriented approach has been demonstrated on the eye and allows to increase the diameter of the corrected image by a factor of approximately 2-3. Difficulties in the tomographic reconstruction precludes the correction of larger fields. Here we have investigate the possibility to apply a layer-oriented MCAO approach to retinal imaging.

  20. Compact and mobile high resolution PET brain imager

    DOE Patents [OSTI]

    Majewski, Stanislaw (Yorktown, VA); Proffitt, James (Newport News, VA)

    2011-02-08T23:59:59.000Z

    A brain imager includes a compact ring-like static PET imager mounted in a helmet-like structure. When attached to a patient's head, the helmet-like brain imager maintains the relative head-to-imager geometry fixed through the whole imaging procedure. The brain imaging helmet contains radiation sensors and minimal front-end electronics. A flexible mechanical suspension/harness system supports the weight of the helmet thereby allowing for patient to have limited movements of the head during imaging scans. The compact ring-like PET imager enables very high resolution imaging of neurological brain functions, cancer, and effects of trauma using a rather simple mobile scanner with limited space needs for use and storage.

  1. High resolution A/D conversion based on piecewise conversion at lower resolution

    SciTech Connect (OSTI)

    Terwilliger, Steve (Albuquerque, NM)

    2012-06-05T23:59:59.000Z

    Piecewise conversion of an analog input signal is performed utilizing a plurality of relatively lower bit resolution A/D conversions. The results of this piecewise conversion are interpreted to achieve a relatively higher bit resolution A/D conversion without sampling frequency penalty.

  2. Cryogenic, high-resolution x-ray detector with high count rate capability

    DOE Patents [OSTI]

    Frank, Matthias (Oakland, CA); Mears, Carl A. (Windsor, CA); Labov, Simon E. (Berkeley, CA); Hiller, Larry J. (Livermore, CA); Barfknecht, Andrew T. (Menlo Park, CA)

    2003-03-04T23:59:59.000Z

    A cryogenic, high-resolution X-ray detector with high count rate capability has been invented. The new X-ray detector is based on superconducting tunnel junctions (STJs), and operates without thermal stabilization at or below 500 mK. The X-ray detector exhibits good resolution (.about.5-20 eV FWHM) for soft X-rays in the keV region, and is capable of counting at count rates of more than 20,000 counts per second (cps). Simple, FET-based charge amplifiers, current amplifiers, or conventional spectroscopy shaping amplifiers can provide the electronic readout of this X-ray detector.

  3. High resolution fossil fuel combustion CO2 emission fluxes for the United States

    SciTech Connect (OSTI)

    Gurney, Kevin R.; Mendoza, Daniel L.; Zhou, Yuyu; Fischer, Marc L.; Miller, Chris C.; Geethakumar, Sarath; de la Rue du Can, Stephane

    2009-03-19T23:59:59.000Z

    Quantification of fossil fuel CO{sub 2} emissions at fine space and time resolution is emerging as a critical need in carbon cycle and climate change research. As atmospheric CO{sub 2} measurements expand with the advent of a dedicated remote sensing platform and denser in situ measurements, the ability to close the carbon budget at spatial scales of {approx}100 km{sup 2} and daily time scales requires fossil fuel CO{sub 2} inventories at commensurate resolution. Additionally, the growing interest in U.S. climate change policy measures are best served by emissions that are tied to the driving processes in space and time. Here we introduce a high resolution data product (the 'Vulcan' inventory: www.purdue.edu/eas/carbon/vulcan/) that has quantified fossil fuel CO{sub 2} emissions for the contiguous U.S. at spatial scales less than 100 km{sup 2} and temporal scales as small as hours. This data product, completed for the year 2002, includes detail on combustion technology and 48 fuel types through all sectors of the U.S. economy. The Vulcan inventory is built from the decades of local/regional air pollution monitoring and complements these data with census, traffic, and digital road data sets. The Vulcan inventory shows excellent agreement with national-level Department of Energy inventories, despite the different approach taken by the DOE to quantify U.S. fossil fuel CO{sub 2} emissions. Comparison to the global 1{sup o} x 1{sup o} fossil fuel CO{sub 2} inventory, used widely by the carbon cycle and climate change community prior to the construction of the Vulcan inventory, highlights the space/time biases inherent in the population-based approach.

  4. Ultra-high Resolution Optics for EUV and Soft X-ray Inelastic Scattering

    E-Print Network [OSTI]

    Voronov, Dmitry L.

    2010-01-01T23:59:59.000Z

    16. Yu. Shvyd’ko, X-Ray Optics, Berlin: Springer-Verlag,Ultra-high Resolution Optics for EUV and Soft X-rayspectral resolution soft x-ray optics. Conventionally in the

  5. Nanoscale organic transistors that use sourcedrain electrodes supported by high resolution rubber stamps

    E-Print Network [OSTI]

    Rogers, John A.

    Nanoscale organic transistors that use sourceÕdrain electrodes supported by high resolution rubber resolution rubber stamps bilayers of two different types of the elastomer polydimethylsiloxane 3,4 by casting

  6. High-Resolution Residential Feeder Load Characterization and...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    been a number of investigations into the effects of PV variability on distribution circuit voltage 1. Due to load data resolution limitations and the difficulty in estimating...

  7. High resolution neutron imaging of water in PEM fuel cells

    SciTech Connect (OSTI)

    Mukundan, Rangachary [Los Alamos National Laboratory; Borup, Rodney L [Los Alamos National Laboratory; Davey, John R [Los Alamos National Laboratory; Spendelow, Jacob S [Los Alamos National Laboratory

    2008-01-01T23:59:59.000Z

    Optimal water management in Polymer Electrolyte Membrane (PEM) fuel cells is critical to improving the performance and durability of fuel cell systems especially during transient, start-up and shut-down operations. For example, while a high water content is desirable for improved membrane and catalyst ionomer conductivity, high water content can also block gas access to the triple-phase boundary resulting in lowered performance due to catalyst and gas diffusion layer (GDL) flooding. Visualizing liquid water by neutron imaging has been used over the past decade to study the water distribution inside operating fuel cells. In this paper, the results from our imaging at NIST using their recently installed higher resolution ({approx} 25 mm) Microchannel Plate (MCP) detector with a pixel pitch of 14.7 mm are presented. This detector is capable of quantitatively imaging the water inside the MEA (Membrane Electrode Assembly)/GDL (Gas Diffusion Layer) of working fuel cells and can provide the water profiles within these various components in addition to the channel water. Specially designed fuel cells (active area = 2.25 cm{sup 2}) have been used in order to take advantage of the full detector resolution. The cell design is illustrated in a figure where one of the current collector/end plates is shown. The serpentine pattern was machined into a block of aluminum and plated with nickel and then gold to form the flow field. The measurements were performed using beam no. 1 and aperture no. 2 with a fluence rate of 1.9 x 10{sup 6} neutrons cm{sup -2} sec{sup -1}. The cells were assembled with Gore{sup TM} Primea{sup R} MEAs and SGL Sigracet {sup R} 24 series GDLs (PRIMEA, GORE-SELECT and GORE are trademarks of W. L. Gore & Associates, Inc). All the cells were tested at 80 {sup o}C with 1.2 stoichiometry H{sub 2} and 2.0 stoichiometry air flows.

  8. Chandra High Resolution X-ray Spectroscopy of AM Her

    E-Print Network [OSTI]

    V. Girish; V. R. Rana; K. P. Singh

    2007-02-14T23:59:59.000Z

    We present the results of high resolution spectroscopy of the prototype polar AM Herculis observed with Chandra High Energy Transmission Grating. The X-ray spectrum contains hydrogen-like and helium-like lines of Fe, S, Si, Mg, Ne and O with several Fe L-shell emission lines. The forbidden lines in the spectrum are generally weak whereas the hydrogen-like lines are stronger suggesting that emission from a multi-temperature, collisionally ionized plasma dominates. The helium-like line flux ratios yield a plasma temperature of 2 MK and a plasma density 1 - 9 x10^12 cm^-3, whereas the line flux ratio of Fe XXVI to Fe XXV gives an ionization temperature of 12.4 +1.1 -1.4 keV. We present the differential emission measure distribution of AM Her whose shape is consistent with the volume emission measure obtained by multi-temperature APEC model. The multi-temperature plasma model fit to the average X-ray spectrum indicates the mass of the white dwarf to be ~1.15 M_sun. From phase resolved spectroscopy, we find the line centers of Mg XII, S XVI, resonance line of Fe XXV, and Fe XXVI emission modulated by a few hundred to 1000 km/s from the theoretically expected values indicating bulk motion of ionized matter in the accretion column of AM Her. The observed velocities of Fe XXVI ions are close to the expected shock velocity for a 0.6 M_sun white dwarf. The observed velocity modulation is consistent with that expected from a single pole accreting binary system.

  9. INNER SHELL EXCITATION OF ATOMS AND MOLECULES BY ELECTRON IMPACT WITH HIGH ENERGY RESOLUTION

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    INNER SHELL EXCITATION OF ATOMS AND MOLECULES BY ELECTRON IMPACT WITH HIGH ENERGY RESOLUTION F. H resolution energy loss spectra for inner shell excited states, (2) the observa- tion of inner shell excited are the subject of the present review. The inner shell states that can usefully be studied with energy resolutions

  10. High intrinsic energy resolution photon number resolving detectors

    E-Print Network [OSTI]

    Lolli, L; Portesi, C; Monticone, E; Rajteri, M

    2013-01-01T23:59:59.000Z

    Transition Edge Sensors (TESs) are characterized by the intrinsic figure of merit to resolve both the energy and the statistical distribution of the incident photons. These properties lead TES devices to become the best single photon detector for quantum technology experiments. For a TES based on titanium and gold has been reached, at telecommunication wavelength, an unprecedented intrinsic energy resolution (0.113 eV). The uncertainties analysis of both energy resolution and photon state assignment has been discussed. The thermal properties of the superconductive device have been studied by fitting the bias curve to evaluate theoretical limit of the energy resolution.

  11. Magnetic nanowire based high resolution magnetic force microscope probes

    E-Print Network [OSTI]

    Qin, Lu-Chang

    -resolution magnetic force microscope probes using preformed magnetic nanowires. Nickel and cobalt nanowires produced by electrodeposition were directly assembled onto the tip of a commercial atomic force microscope cantilever

  12. 2013 American Geophysical Union. All Rights Reserved. High resolution imaging of the melt distribution in 1

    E-Print Network [OSTI]

    © 2013 American Geophysical Union. All Rights Reserved. High resolution imaging of the melt;© 2013 American Geophysical Union. All Rights Reserved. Abstract We determine the 3-D melt geometry

  13. applying high-resolution detectors: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    since Spring 1999. Stereo 3 Using High-Resolution Detector and Signal Data to Support Energy Storage, Conversion and Utilization Websites Summary: data collection and storage...

  14. area high-resolution ccd-based: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    CCD-Based Thermoreflectance Techniques for High-Resolution Transient Thermal Imaging Energy Storage, Conversion and Utilization Websites Summary: on the small but detectable...

  15. (SO2)-S-34-O-16: High-resolution analysis of the (030),(101)...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    (111), (002) and (201) vibrational states; determination of Abstract: High resolution Fourier transform spectra of a sample of sulfur dioxide, enriched in 34S (95.3%). were...

  16. 4-D High-Resolution Seismic Reflection Monitoring of Miscible CO2 Injected into a Carbonate Reservoir

    SciTech Connect (OSTI)

    Richard D. Miller; Abdelmoneam E. Raef; Alan P. Byrnes; William E. Harrison

    2007-06-30T23:59:59.000Z

    The objective of this research project was to acquire, process, and interpret multiple high-resolution 3-D compressional wave and 2-D, 2-C shear wave seismic data in the hopes of observing changes in fluid characteristics in an oil field before, during, and after the miscible carbon dioxide (CO{sub 2}) flood that began around December 1, 2003, as part of the DOE-sponsored Class Revisit Project (DOE No.DE-AC26-00BC15124). Unique and key to this imaging activity is the high-resolution nature of the seismic data, minimal deployment design, and the temporal sampling throughout the flood. The 900-m-deep test reservoir is located in central Kansas oomoldic limestones of the Lansing-Kansas City Group, deposited on a shallow marine shelf in Pennsylvanian time. After 30 months of seismic monitoring, one baseline and eight monitor surveys clearly detected changes that appear consistent with movement of CO{sub 2} as modeled with fluid simulators and observed in production data. Attribute analysis was a very useful tool in enhancing changes in seismic character present, but difficult to interpret on time amplitude slices. Lessons learned from and tools/techniques developed during this project will allow high-resolution seismic imaging to be routinely applied to many CO{sub 2} injection programs in a large percentage of shallow carbonate oil fields in the midcontinent.

  17. Upgrades of the high resolution imaging x-ray crystal spectrometers on experimental advanced superconducting tokamak

    SciTech Connect (OSTI)

    Lu, B.; Wang, F.; Fu, J.; Li, Y.; Wan, B. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Shi, Y. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); National Fusion Research Institute, 52 Eoeun-Dong, Yusung-Gu, Daejeon (Korea, Republic of); Bitter, M.; Hill, K. W. [Princeton Plasma Physics Laboratory, MS37-B332, Princeton, New Jersey 08543-0451 (United States); Lee, S. G. [National Fusion Research Institute, 52 Eoeun-Dong, Yusung-Gu, Daejeon (Korea, Republic of)

    2012-10-15T23:59:59.000Z

    Two imaging x-ray crystal spectrometers, the so-called 'poloidal' and 'tangential' spectrometers, were recently implemented on experimental advanced superconducting tokamak (EAST) to provide spatially and temporally resolved impurity ion temperature (T{sub i}), electron temperature (T{sub e}) and rotation velocity profiles. They are derived from Doppler width of W line for Ti, the intensity ratio of Li-like satellites to W line for Te, and Doppler shift of W line for rotation. Each spectrometer originally consisted of a spherically curved crystal and a two-dimensional multi-wire proportional counter (MWPC) detector. Both spectrometers have now been upgraded. The layout of the tangential spectrometer was modified, since it had to be moved to a different port, and the spectrometer was equipped with two high count rate Pilatus detectors (Model 100 K) to overcome the count rate limitation of the MWPC and to improve its time resolution. The poloidal spectrometer was equipped with two spherically bent crystals to record the spectra of He-like and H-like argon simultaneously and side by side on the original MWPC. These upgrades are described, and new results from the latest EAST experimental campaign are presented.

  18. High resolution non-contact thermal characterization of semiconductor devices

    E-Print Network [OSTI]

    imaging can have spatial resolution better than the diffraction limit of an infrared camera and can work infrared microscopes. Also, since the thermoreflectance technique does not rely upon the emitted black body measured the heating on a 35x35 micron MOS transistor, and Mansanares5 who measured temperature

  19. Probe for high resolution NMR with sample reorientation

    DOE Patents [OSTI]

    Pines, Alexander (Berkeley, CA); Samoson, Ago (Tallinn, SU)

    1990-01-01T23:59:59.000Z

    An improved NMR probe and method are described which substantially improve the resolution of NMR measurements made on powdered or amorphous or otherwise orientationally disordered samples. The apparatus mechanically varies the orientation of the sample such that the time average of two or more sets of spherical harmonic functions are zero.

  20. Probe for high resolution NMR with sample reorientation

    DOE Patents [OSTI]

    Pines, A.; Samoson, A.

    1990-02-06T23:59:59.000Z

    An improved NMR probe and method are described which substantially improve the resolution of NMR measurements made on powdered or amorphous or otherwise orientationally disordered samples. The apparatus mechanically varies the orientation of the sample such that the time average of two or more sets of spherical harmonic functions are zero. 8 figs.

  1. A Steerable Laser System for Atmospheric Monitoring at the High Resolution Flys Eye

    E-Print Network [OSTI]

    and radiometer . The energy 2 released into the sky is determined by multiplying this measurementOG 4.5.10 A Steerable Laser System for Atmospheric Monitoring at the High Resolution Flys Eye J. R. Mumford , R. C. Gray , L. R. Wiencke for the 1 1 1 High Resolution Flys Eye Collaboration 1. Physics

  2. High Resolution Wave Propagation Schemes for Two-Fluid Plasma Simulations

    E-Print Network [OSTI]

    Shumlak, Uri

    High Resolution Wave Propagation Schemes for Two-Fluid Plasma Simulations Ammar H. Hakim Information and Learning, 300 North Zeeb Road, Ann Arbor, MI 48106-1346, 1-800-521-0600, to whom the author Abstract High Resolution Wave Propagation Schemes for Two-Fluid Plasma Simulations Ammar H. Hakim Chair

  3. ATTEMPT OF ALPINE GLACIER FLOW MODELING BASED ON CORRELATION MEASUREMENTS OF HIGH RESOLUTION SAR IMAGES

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    ATTEMPT OF ALPINE GLACIER FLOW MODELING BASED ON CORRELATION MEASUREMENTS OF HIGH RESOLUTION SAR In this paper, an attempt of Alpine glacier flow modeling is performed based on a series of high resolution TerraSAR-X SAR images and a Digital Elevation Model. First, a glacier flow model is established

  4. Evaluation of a CCD-based high resolution autocollimator for use as a slope sensor

    E-Print Network [OSTI]

    Baltisberger, Jay H.

    Evaluation of a CCD-based high resolution autocollimator for use as a slope sensor Rohan Isaac the focused beam profile to broaden and decrease its peak intensity Project: Evaluation of a compact CCD-based high resolution autocollimator with a small probe beam for potential use as a slope sensor Optics Group

  5. A NEW HIGH ENERGY RESOLUTION NEUTRON TRANSMISSION DETECTOR SYSTEM AT THE GAERTTNER LINAC LABORATORY

    E-Print Network [OSTI]

    Danon, Yaron

    Laboratory P.O. Box 1072, Schenectady, New York 12301-1072 A new high energy resolution modular neutronA NEW HIGH ENERGY RESOLUTION NEUTRON TRANSMISSION DETECTOR SYSTEM AT THE GAERTTNER LINAC LABORATORY capabilities at the Laboratory in and above the resolved resonance energy region from 1 keV to 600 ke

  6. Range imaging: a new method for high-resolution topographic measurements in small-and medium-

    E-Print Network [OSTI]

    Kirchner, James W.

    Range imaging: a new method for high-resolution topographic measurements in small- and medium is a useful complement or alternative to existing methods for high-resolution measurements in small- to medium has led to a dramatic increase in terrain information and opened up new opportunities for hydro- logic

  7. Experimental measurement of human head motion for high-resolution computed tomography

    E-Print Network [OSTI]

    Wang, Ge

    Experimental measurement of human head motion for high-resolution computed tomography system design experimentally measured for high-resolution computed tomography CT design using a Canon digital camera. Our goal-Optical Instrumentation Engineers. DOI: 10.1117/1.3454379 Subject terms: head motion; computed tomography CT ; image

  8. A comprehensive set of high-resolution grids of monthly climate for Europe and the globe

    E-Print Network [OSTI]

    Watson, Andrew

    on biomass potential in western Europe; Rotmans A comprehensive set of high-resolution grids of monthly climate for Europe and the globe;1 A comprehensive set of high-resolution grids of monthly climate for Europe and the globe: the observed record

  9. A high-resolution mapped grid algorithm for compressible multiphase flow problems

    E-Print Network [OSTI]

    Shyue, Keh-Ming

    A high-resolution mapped grid algorithm for compressible multiphase flow problems K.-M. Shyue mapped grid approach for the efficient numerical simula- tion of compressible multiphase flow in general problems, J. Comput. Phys. 142 (1998) 208-242). A standard high-resolution mapped grid method in wave

  10. Examining the temporal evolution of hypervelocity impact phenomena via high-speed imaging and ultraviolet-visible emission spectroscopy

    SciTech Connect (OSTI)

    Tandy, J. D., E-mail: jt245@le.ac.uk [Department of Chemistry, University of Leicester, Leicester LE1 7RH (United Kingdom); Mihaly, J. M.; Adams, M. A.; Rosakis, A. J. [Graduate Aerospace Laboratories, California Institute of Technology, Pasadena, California 91125 (United States)

    2014-07-21T23:59:59.000Z

    The temporal evolution of a previously observed hypervelocity impact-induced vapor cloud [Mihaly et al., Int. J. Impact Eng. 62, 13 (2013)] was measured by simultaneously recording several full-field, near-IR images of the resulting emission using an OMA-V high-speed camera. A two-stage light-gas gun was used to accelerate 5?mg Nylon 6/6 right-cylinders to speeds between 5?km/s and 7?km/s to impact 1.5?mm thick 6061-T6 aluminum target plates. Complementary laser-side-lighting [Mihaly et al., Int. J. Impact Eng. 62, 13 (2013); Proc. Eng. 58, 363 (2013)] and front-of-target (without laser illumination) images were also captured using a Cordin ultra-high-speed camera. The rapid expansion of the vapor cloud was observed to contain a bright, emitting exterior, and a darker, optically thick interior. The shape of this phenomenon was also observed to vary considerably between experiments due to extremely high-rate (>250?000?rpm) of tumbling of the cylindrical projectiles. Additionally, UV-vis emission spectra were simultaneously recorded to investigate the temporal evolution of the atomic and molecular composition of the up-range, impact-induced vapor plume. A PI-MAX3 high-speed camera coupled to an Acton spectrograph was utilized to capture the UV-vis spectra, which shows an overall peak in emission intensity between approximately 6–10??s after impact trigger, corresponding to an increased quantity of emitting vapor/plasma passing through the spectrometer slit during this time period. The relative intensity of the numerous spectral bands was also observed to vary according to the exposure delay of the camera, indicating that the different atomic/molecular species exhibit a varied temporal evolution during the vapor cloud expansion. Higher resolution spectra yielded additional emission lines/bands that provide further evidence of interaction between fragmented projectile material and the 1?mmHg atmosphere inside the target chamber. A comparison of the data to down-range emission spectra also revealed differences in the relative intensities of the atomic/molecular composition of the observed vapor clouds.

  11. alto high-resolution search: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2010-10-22 7 The Search for Anisotropy in the Arrival Directions of Ultra-High Energy Cosmic Rays Observed by the High Resolution Fly's Eye Detector in Monocular Mode...

  12. alveolitis high-resolution computed: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Geiger, Cathleen 45 High-resolution x-ray telescopes CERN Preprints Summary: High-energy astrophysics is a relatively young scientific field, made possible by space-borne...

  13. Automated analysis for microcalcifications in high resolution digital mammograms

    DOE Patents [OSTI]

    Mascio, Laura N. (Dublin, CA)

    1996-01-01T23:59:59.000Z

    A method for automatically locating microcalcifications indicating breast cancer. The invention assists mammographers in finding very subtle microcalcifications and in recognizing the pattern formed by all the microcalcifications. It also draws attention to microcalcifications that might be overlooked because a more prominent feature draws attention away from an important object. A new filter has been designed to weed out false positives in one of the steps of the method. Previously, iterative selection threshold was used to separate microcalcifications from the spurious signals resulting from texture or other background. A Selective Erosion or Enhancement (SEE) Filter has been invented to improve this step. Since the algorithm detects areas containing potential calcifications on the mammogram, it can be used to determine which areas need be stored at the highest resolution available, while, in addition, the full mammogram can be reduced to an appropriate resolution for the remaining cancer signs.

  14. Automated analysis for microcalcifications in high resolution digital mammograms

    DOE Patents [OSTI]

    Mascio, L.N.

    1996-12-17T23:59:59.000Z

    A method is disclosed for automatically locating microcalcifications indicating breast cancer. The invention assists mammographers in finding very subtle microcalcifications and in recognizing the pattern formed by all the microcalcifications. It also draws attention to microcalcifications that might be overlooked because a more prominent feature draws attention away from an important object. A new filter has been designed to weed out false positives in one of the steps of the method. Previously, iterative selection threshold was used to separate microcalcifications from the spurious signals resulting from texture or other background. A Selective Erosion or Enhancement (SEE) Filter has been invented to improve this step. Since the algorithm detects areas containing potential calcifications on the mammogram, it can be used to determine which areas need be stored at the highest resolution available, while, in addition, the full mammogram can be reduced to an appropriate resolution for the remaining cancer signs. 8 figs.

  15. High-resolution retinal imaging using adaptive optics and Fourier-domain optical coherence tomography

    DOE Patents [OSTI]

    Olivier, Scot S. (Livermore, CA); Werner, John S. (Davis, CA); Zawadzki, Robert J. (Sacramento, CA); Laut, Sophie P. (Pasedena, CA); Jones, Steven M. (Livermore, CA)

    2010-09-07T23:59:59.000Z

    This invention permits retinal images to be acquired at high speed and with unprecedented resolution in three dimensions (4.times.4.times.6 .mu.m). The instrument achieves high lateral resolution by using adaptive optics to correct optical aberrations of the human eye in real time. High axial resolution and high speed are made possible by the use of Fourier-domain optical coherence tomography. Using this system, we have demonstrated the ability to image microscopic blood vessels and the cone photoreceptor mosaic.

  16. Toroidal magnetic detector for high resolution measurement of muon momenta

    DOE Patents [OSTI]

    Bonanos, P.

    1992-01-07T23:59:59.000Z

    A muon detector system including central and end air-core superconducting toroids and muon detectors enclosing a central calorimeter/detector. Muon detectors are positioned outside of toroids and all muon trajectory measurements are made in a nonmagnetic environment. Internal support for each magnet structure is provided by sheets, located at frequent and regularly spaced azimuthal planes, which interconnect the structural walls of the toroidal magnets. In a preferred embodiment, the shape of the toroidal magnet volume is adjusted to provide constant resolution over a wide range of rapidity. 4 figs.

  17. The Importance of High Temporal Resolution in Modeling Renewable Energy Penetration Scenarios

    E-Print Network [OSTI]

    Nicolosi, Marco

    2011-01-01T23:59:59.000Z

    Austin. ERCOT (2010b): Wind generation and load in 2008,common to subtract wind generation from total demand to formquantity of additional wind generation to demonstrate how

  18. The Importance of High Temporal Resolution in Modeling Renewable Energy Penetration Scenarios

    E-Print Network [OSTI]

    Nicolosi, Marco

    2011-01-01T23:59:59.000Z

    Because of these dynamics, wholesale power prices tend to bedispatch patterns and wholesale power prices, however, alsoTab 2). Because it impacts wholesale power prices and wind

  19. The Importance of High Temporal Resolution in Modeling Renewable Energy Penetration Scenarios

    E-Print Network [OSTI]

    Nicolosi, Marco

    2011-01-01T23:59:59.000Z

    for Competitive Renewable Energy Zones in Texas, Report,Supply, National Renewable Energy Laboratory. Sensfuß, F. ,in Modeling Renewable Energy Penetration Scenarios Marco

  20. OVERVIEW OF SELECTED SURROGATE TECHNOLOGIES FOR HIGH-TEMPORAL RESOLUTION SUSPENDED-SEDIMENT MONITORING

    E-Print Network [OSTI]

    price of a fully equipped in-situ turbidimeter with an optical window wiper was about $5,000. Purchase

  1. The Importance of High Temporal Resolution in Modeling Renewable Energy Penetration Scenarios

    E-Print Network [OSTI]

    Nicolosi, Marco

    2011-01-01T23:59:59.000Z

    impacts wholesale power prices and wind energy curtailmentPrices and Incentives to Invest in Thermal Power Plants under Increasing Wind Energyprice discussion is the wholesale market value of wind energy,

  2. The Importance of High Temporal Resolution in Modeling Renewable Energy Penetration Scenarios

    E-Print Network [OSTI]

    Nicolosi, Marco

    2011-01-01T23:59:59.000Z

    wind power in a carbon constrained world, Energy Policy,Wind Power in the Danish liberalized power market – Policy measures, price impact and investor incentives, Energy Policy,wind energy curtailment decisions, an assumption for the $-per-kWh level of policy

  3. High resolution polarimeter-interferometer system for fast equilibrium dynamics and MHD instability studies on Joint-TEXT tokamak (invited)

    SciTech Connect (OSTI)

    Chen, J.; Zhuang, G., E-mail: ge-zhuang@hust.edu.cn; Li, Q.; Liu, Y.; Gao, L.; Zhou, Y. N.; Jian, X.; Xiong, C. Y.; Wang, Z. J. [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074 (China); Brower, D. L.; Ding, W. X. [Department of Physics and Astronomy, University of California Los Angeles, Los Angeles, California 90095 (United States)

    2014-11-15T23:59:59.000Z

    A high-performance Faraday-effect polarimeter-interferometer system has been developed for the J-TEXT tokamak. This system has time response up to 1 ?s, phase resolution < 0.1° and minimum spatial resolution ?15 mm. High resolution permits investigation of fast equilibrium dynamics as well as magnetic and density perturbations associated with intrinsic Magneto-Hydro-Dynamic (MHD) instabilities and external coil-induced Resonant Magnetic Perturbations (RMP). The 3-wave technique, in which the line-integrated Faraday angle and electron density are measured simultaneously by three laser beams with specific polarizations and frequency offsets, is used. In order to achieve optimum resolution, three frequency-stabilized HCOOH lasers (694 GHz, >35 mW per cavity) and sensitive Planar Schottky Diode mixers are used, providing stable intermediate-frequency signals (0.5–3 MHz) with S/N > 50. The collinear R- and L-wave probe beams, which propagate through the plasma poloidal cross section (a = 0.25–0.27 m) vertically, are expanded using parabolic mirrors to cover the entire plasma column. Sources of systematic errors, e.g., stemming from mechanical vibration, beam non-collinearity, and beam polarization distortion are individually examined and minimized to ensure measurement accuracy. Simultaneous density and Faraday measurements have been successfully achieved for 14 chords. Based on measurements, temporal evolution of safety factor profile, current density profile, and electron density profile are resolved. Core magnetic and density perturbations associated with MHD tearing instabilities are clearly detected. Effects of non-axisymmetric 3D RMP in ohmically heated plasmas are directly observed by polarimetry for the first time.

  4. Highly ecient kinetic resolution of 2-cyclohexenyl acetate in Pd-catalyzed allylic alkylation

    E-Print Network [OSTI]

    Zhang, Xumu

    Highly ecient kinetic resolution of 2-cyclohexenyl acetate in Pd-catalyzed allylic alkylation James resolution of 2-cyclohexenyl acetate was observed during alkylation. In addition, the reactivity and enantioselectivity showed a strong dependence on the acetate salt with the BSA/MOAc (M=alkali metal) base system

  5. High Resolution Backside Imaging and Thermography using a Numerical Aperture Increasing Lens

    E-Print Network [OSTI]

    High Resolution Backside Imaging and Thermography using a Numerical Aperture Increasing Lens Shawn inspection alone, it is necessary to develop techniques, such as thermography, with the capability ­solid immersion lens microscopy and thermography. Standard non-contact optical resolution is limited

  6. Collimator selection for SPECT brain imaging: the advantage of high resolution

    SciTech Connect (OSTI)

    Mueller, S.P.; Polak, J.F.; Kijewski, M.F.; Holman, B.L.

    1986-11-01T23:59:59.000Z

    We compared a prototype long-bore (LB) high-resolution collimator with a low-energy, general-purpose collimator (LEGP) using 99mTc and /sup 123/I. The LB collimator provided a 56% improvement in tomographic resolution (autocorrelation width) over the LEGP for 99mTc; for /sup 123/I, the gain was 79%, providing substantially improved contrast for small structures. The sensitivity of the LB collimator, however, is only 32% of that of the LEGP. The imaging tasks to be performed on (/sup 123/I)IMP brain scans involve localization and discrimination of small, high-contrast brain structures and detection of abnormalities in shape, size, or uptake, rather than simple detection of lesions. Observer performance in such higher-order imaging tasks is known to depend on high spatial resolution, even at the cost of sensitivity. Patient studies confirmed that, for resolution-limited tasks, the increase in resolution outweighs the increased noise due to a loss in sensitivity. When the tomographic resolution of the LB collimator was degraded by smoothing to that of the LEGP, the noise in the LB images was lower than that of the LEGP by a factor of 2.9 for the same imaging time, demonstrating the advantage of high-resolution detectors and a smooth reconstruction filter over low-resolution detectors without smoothing. Therefore, collimators designed for high resolution, even at substantial cost in sensitivity, are expected to yield significant improvements for brain SPECT. Geometric calculations show that commercially available low-energy, high-resolution cast collimators promise to meet these requirements.

  7. A Warm Near-Infrared High-Resolution Spectrograph with Very High Throughput (WINERED)

    E-Print Network [OSTI]

    Kondo, Sohei; Kobayashi, Naoto; Yasui, Chikako; Mito, Hiroyuki; Fukue, Kei; Nakanishi, Kenshi; Kawanishi, Takafumi; Nakaoka, Tetsuya; Otsubo, Shogo; Kinoshita, Masaomi; Kitano, Ayaka; Hamano, Satoshi; Mizumoto, Misaki; Yamamoto, Ryo; Izumi, Natsuko; Matsunaga, Noriyuki; Kawakita, Hideyo

    2015-01-01T23:59:59.000Z

    WINERED is a newly built high-efficiency (throughput$ > 25-30\\%$) and high-resolution spectrograph customized for short NIR bands at 0.9-1.35 ${\\rm \\mu}$m. WINERED is equipped with ambient temperature optics and a cryogenic camera using a 1.7 ${\\rm \\mu}$m cut-off HgCdTe HAWAII-2RG array detector. WINERED has two grating modes: one with a conventional reflective echelle grating (R$\\sim$28,300), which covers 0.9-1.35 $\\mu$m simultaneously, the other with ZnSe or ZnS immersion grating (R$\\sim$100,000). We have completed the development of WINERED except for the immersion grating, and started engineering and science observations at the Nasmyth platform of the 1.3 m Araki Telescope at Koyama Astronomical Observatory of Kyoto-Sangyo University in Japan. We confirmed that the spectral resolution ($R\\sim$ 28,300) and the throughput ($>$ 40\\% w/o telescope/atmosphere/array QE) meet our specifications. We measured ambient thermal backgrounds (e.g., 0.06 ${\\rm [e^{-}/sec/pixel]}$ at 287 K), which are roughly consistent ...

  8. Characterization of spatially resolved high resolution x-ray spectrometers for high energy density physics and light source experiments

    SciTech Connect (OSTI)

    Hill, K. W., E-mail: khill@pppl.gov; Bitter, M.; Delgado-Aparacio, L.; Efthimion, P.; Pablant, N. A. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Lu, J. [Key Laboratory of Optoelectronic Technology and System of Ministry of Education, Chongqing University, Chongqing 400030 (China); Beiersdorfer, P.; Chen, H.; Magee, E. [Physics Division, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2014-11-15T23:59:59.000Z

    A high resolution 1D imaging x-ray spectrometer concept comprising a spherically bent crystal and a 2D pixelated detector is being optimized for diagnostics of small sources such as high energy density physics (HEDP) and synchrotron radiation or x-ray free electron laser experiments. This instrument is used on tokamak experiments for Doppler measurements of ion temperature and plasma flow velocity profiles. Laboratory measurements demonstrate a resolving power, E/?E of order 10?000 and spatial resolution better than 10 ?m. Initial tests of the high resolution instrument on HEDP plasmas are being performed.

  9. High resolution ion Doppler spectroscopy at Prairie View Rotamak

    SciTech Connect (OSTI)

    Houshmandyar, Saeid; Yang Xiaokang [Solar Observatory Department, Prairie View A and M University, Prairie View, Texas 77446 (United States); Magee, Richard [Department of Physics, West Virginia University, Morgantown, West Virginia 26506 (United States)

    2012-10-15T23:59:59.000Z

    A fast ion Doppler spectroscopy (IDS) diagnostic system is installed on the Prairie View Rotamak to measure ion temperature and plasma flow. The diagnostic employs a single channel photomultiplier tube and a Jarrell-Ash 50 monochromator with a diffraction grating line density of 1180 lines/mm, which allows for first order spectra of 200-600 nm. The motorized gear of the monochromator allows spectral resolution of 0.01 nm. Equal IDS measurements are observed for various impurity emission lines of which carbon lines exhibit stronger intensities. Furthermore, the diagnostics is examined in an experiment where plasma experiences sudden disruption and quick recovery. In this case, the IDS measurements show {approx}130% increase in ion temperature. Flow measurements are shown to be consistent with plasma rotation.

  10. Morphological Characteristics of Compact High-Velocity Clouds Revealed by High-Resolution WSRT Imaging

    E-Print Network [OSTI]

    W. B. Burton; Robert Braun

    1999-12-22T23:59:59.000Z

    A class of compact, isolated high-velocity clouds which plausibly represents a homogeneous subsample of the HVC phenomenon in a single physical state was objectively identified by Braun and Burton (1999). Six examples of the CHVCs, unresolved in single-dish data, have been imaged with the Westerbork Synthesis Radio Telescope. The high-resolution imaging reveals the morphology of these objects, including a core/halo distribution of fluxes, signatures of rotation indicating dark matter, and narrow linewidths constraining the kinetic temperature of several opaque cores. In these regards, as well as in their kinematic and spatial deployment on the sky, the CHVC objects are evidently a dynamically cold ensemble of dark-matter-dominated HI clouds accreting onto the Local Group in a continuing process of galactic evolution.

  11. HIGH ANGULAR RESOLUTION OBSERVATIONS OF FOUR CANDIDATE BLAST HIGH-MASS STARLESS CORES

    SciTech Connect (OSTI)

    Olmi, Luca; Poventud, Carlos M. [Physics Department, Rio Piedras Campus, University of Puerto Rico, Box 23343, UPR Station, San Juan, Puerto Rico (United States); Araya, Esteban D. [Physics Department, Western Illinois University, 1 University Circle, Macomb, IL 61455 (United States); Chapin, Edward L.; Gibb, Andrew [Department of Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, BC V6T 1Z1 (Canada); Hofner, Peter [Physics Department, New Mexico Institute of Mining and Technology, 801 Leroy Place, Socorro, NM 87801 (United States); Martin, Peter G., E-mail: olmi.luca@gmail.co, E-mail: olmi@arcetri.astro.i [Canadian Institute for Theoretical Astrophysics, University of Toronto, 60 St. George Street, Toronto, ON M5S 3H8 (Canada)

    2010-06-01T23:59:59.000Z

    We discuss high angular resolution observations of ammonia toward four candidate high-mass starless cores (HMSCs). The cores were identified by the Balloon-borne Large Aperture Submillimeter Telescope (BLAST) during its 2005 survey of the Vulpecula region where 60 compact sources were detected simultaneously at 250, 350, and 500 {mu}m. Four of these cores, with no IRAS-PSC or MSX counterparts, were mapped with the NRAO Very Large Array and observed with the Effelsberg 100 m telescope in the NH{sub 3}(1,1) and (2,2) spectral lines. Our observations indicate that the four cores are cold (T {sub k} < 16 K) and show a filamentary and/or clumpy structure. They also show a significant velocity substructure within {approx}1 km s{sup -1}. The four BLAST cores appear to be colder and more quiescent than other previously observed HMSC candidates, suggesting an earlier stage of evolution.

  12. automatic high resolution: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    with its Sun 3 workstations, Sun Melvin, Stephen 24 Automatic keywording of High Energy Physics CERN Preprints Summary: Bibliographic databases were developed from the...

  13. High-resolution ab initio three-dimensional x-ray diffraction microscopy

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Chapman, Henry N.; Barty, Anton; Marchesini, Stefano; Noy, Aleksandr; Hau-Riege, Stefan P.; Cui, Congwu; Howells, Malcolm R.; Rosen, Rachel; He, Haifeng; Spence, John C.; et al

    2006-01-01T23:59:59.000Z

    Coherent x-ray diffraction microscopy is a method of imaging nonperiodic isolated objects at resolutions limited, in principle, by only the wavelength and largest scattering angles recorded. We demonstrate x-ray diffraction imaging with high resolution in all three dimensions, as determined by a quantitative analysis of the reconstructed volume images. These images are retrieved from the three-dimensional diffraction data using no a priori knowledge about the shape or composition of the object, which has never before been demonstrated on a nonperiodic object. We also construct two-dimensional images of thick objects with greatly increased depth of focus (without loss of transverse spatialmore »resolution). These methods can be used to image biological and materials science samples at high resolution with x-ray undulator radiation and establishes the techniques to be used in atomic-resolution ultrafast imaging at x-ray free-electron laser sources.« less

  14. High-resolution ab initio Three-dimensional X-ray Diffraction Microscopy

    SciTech Connect (OSTI)

    Chapman, H N; Barty, A; Marchesini, S; Noy, A; Cui, C; Howells, M R; Rosen, R; He, H; Spence, J H; Weierstall, U; Beetz, T; Jacobsen, C; Shapiro, D

    2005-08-19T23:59:59.000Z

    Coherent X-ray diffraction microscopy is a method of imaging non-periodic isolated objects at resolutions only limited, in principle, by the largest scattering angles recorded. We demonstrate X-ray diffraction imaging with high resolution in all three dimensions, as determined by a quantitative analysis of the reconstructed volume images. These images are retrieved from the 3D diffraction data using no a priori knowledge about the shape or composition of the object, which has never before been demonstrated on a non-periodic object. We also construct 2D images of thick objects with infinite depth of focus (without loss of transverse spatial resolution). These methods can be used to image biological and materials science samples at high resolution using X-ray undulator radiation, and establishes the techniques to be used in atomic-resolution ultrafast imaging at X-ray free-electron laser sources.

  15. High-resolution ab initio three-dimensional x-ray diffraction microscopy

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Chapman, Henry N.; Barty, Anton; Marchesini, Stefano; Noy, Aleksandr; Hau-Riege, Stefan P.; Cui, Congwu; Howells, Malcolm R.; Rosen, Rachel; He, Haifeng; Spence, John C.; Weierstall, Uwe; Beetz, Tobias; Jacobsen, Chris; Shapiro, David

    2006-01-01T23:59:59.000Z

    Coherent x-ray diffraction microscopy is a method of imaging nonperiodic isolated objects at resolutions limited, in principle, by only the wavelength and largest scattering angles recorded. We demonstrate x-ray diffraction imaging with high resolution in all three dimensions, as determined by a quantitative analysis of the reconstructed volume images. These images are retrieved from the three-dimensional diffraction data using no a priori knowledge about the shape or composition of the object, which has never before been demonstrated on a nonperiodic object. We also construct two-dimensional images of thick objects with greatly increased depth of focus (without loss of transverse spatial resolution). These methods can be used to image biological and materials science samples at high resolution with x-ray undulator radiation and establishes the techniques to be used in atomic-resolution ultrafast imaging at x-ray free-electron laser sources.

  16. High-resolution imaging of compact high-velocity clouds (II)

    E-Print Network [OSTI]

    V. de Heij; R. Braun; W. B. Burton

    2002-06-19T23:59:59.000Z

    We have imaged five compact high-velocity clouds in HI with arcmin angular- and km/s spectral-resolution using the WSRT. Supplementary total-power data, which is fully sensitive to both the cool and warm components of HI, is available for comparison for all the sources, albeit with angular resolutions that vary from 3' to 36'. The fractional HI flux in compact CNM components varies from 4% to 16% in our sample. All objects have at least one local peak in the CNM column which exceeds about 10^19 cm^-2 when observed with arcmin resolution. It is plausible that a peak column density of 1-2x10^19 cm^-2 is a prerequisite for the long-term survival of these sources. One object in our sample, CHVC120-20-443 (Davies' cloud), lies in close projected proximity to the disk of M31. This object is characterized by exceptionally broad linewidths in its CNM concentrations (more than 5 times greater than the median value). These CNM concentrations lie in an arc on the edge of the source facing the M31 disk, while the diffuse HI component of this source has a position offset in the direction of the disk. All of these attributes suggest that CHVC120-20-443 is in a different evolutionary state than most of the other CHVCs which have been studied. Similarly broad CNM linewidths have only been detected in one other object, CHVC111-07-466, which also lies in the Local Group barycenter direction and has the most extreme radial velocity known. A distinct possibility for Davies' cloud seems to be physical interaction of some type with M31. The most likely form of this interaction might be the ram-pressure or tidal- stripping by either one of M31's visible dwarf companions, M32 or NGC205, or else by a dark companion with an associated HI condensation.

  17. Design of electronics for a high-resolution, multi-material, and modular 3D printer

    E-Print Network [OSTI]

    Kwan, Joyce G

    2013-01-01T23:59:59.000Z

    Electronics for a high-resolution, multi-material, and modular 3D printer were designed and implemented. The driver for a piezoelectric inkjet print head can fire its nozzles with one of three droplet sizes ranging from 6 ...

  18. SEX DIFFERENCES IN THE HUMAN CONNECTOME: 4-TESLA HIGH ANGULAR RESOLUTION DIFFUSION IMAGING (HARDI)

    E-Print Network [OSTI]

    Thompson, Paul

    SEX DIFFERENCES IN THE HUMAN CONNECTOME: 4-TESLA HIGH ANGULAR RESOLUTION DIFFUSION IMAGING (HARDI diffusion imaging at 4 Tesla, we scanned 234 young adult twins and siblings (mean age: 23.4 ± 2.0 SD years

  19. A machine learning model of Manhattan air pollution at high spatial resolution

    E-Print Network [OSTI]

    Keeler, Rachel H. (Rachel Heiden)

    2014-01-01T23:59:59.000Z

    A machine-learning model was created to predict air pollution at high spatial resolution in Manhattan, New York using taxi trip data. Urban air pollution increases morbidity and mortality through respiratory and cardiovascular ...

  20. High resolution laser spectroscopy of cesium and rubidium molecules with optically induced coherence 

    E-Print Network [OSTI]

    Chen, Hui

    2006-10-30T23:59:59.000Z

    This work is devoted to the study of the quantum coherent effects in diatomic molecular systems by using high resolution laser spectroscopy. In particular, we have studied the rubidium diatomic molecular gaseous medium's absorption spectrum...

  1. High-resolution three-dimensional optical coherence tomography imaging of kidney microanatomy ex vivo

    E-Print Network [OSTI]

    Chen, Yu

    Optical coherence tomography (OCT) is an emerging medical imaging technology that enables high-resolution, noninvasive, cross-sectional imaging of microstructure in biological tissues in situ and in real time. When combined ...

  2. High-resolution 7-Tesla fMRI of Human Hippocampal Subfields during Associative Learning.

    E-Print Network [OSTI]

    2014-01-01T23:59:59.000Z

    fMRI in the Human Brain at 7 Tesla: Combining Reduced Field-High-resolution 7-Tesla fMRI of Human Hippocampal Subfieldsrobustly using FMRI at 7 tesla. Journal of Neuroimaging, 23(

  3. High resolution CMRO2 in visual cortex of macaca mulatta Y. Bohraus1

    E-Print Network [OSTI]

    the contribution of the vascular system and neural energy consumption. Measuring CMRO2 allows one to determine with previous MR and PET results such as reviewed in [7]. In conclusion, we showed that high resolution CMRO2

  4. HIGH-RESOLUTION X-RAY SPECTROSCOPY OF THE MULTIPHASE INTERSTELLAR MEDIUM TOWARD Cyg X-2

    E-Print Network [OSTI]

    Schulz, Norbert S.

    High-resolution X-ray absorption spectroscopy is a powerful diagnostic tool for probing chemical and physical properties of the interstellar medium (ISM) at various phases. We present detections of K transition absorption ...

  5. New optics technology opens door to high-resolution atomic-level...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    optics technology opens door to high-resolution atomic-level hard X-ray studies June 8, 2015 Tweet EmailPrint An international collaboration involving two U.S. Department of Energy...

  6. Identification of honeycomb sandwich properties by high-resolution modal analysis

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    implementations. The high-resolution modal analysis (HRMA) technique [5] is an alternative to the FT of the modal analysis of a large panel (lx,y/h 80). The HRMA technique is used to estimate modal frequencies

  7. High resolution melt analysis (HRMA) for detection of CRISPR indels Andrew Bassett 19th

    E-Print Network [OSTI]

    High resolution melt analysis (HRMA) for detection of CRISPR indels Andrew Bassett 19th June 2013 approximately 1 ul per 10 ul PCR reaction HRMA analysis 1. Design primers to amplify 100-200 bp product across

  8. High-Resolution Characterization of Reservoir Heterogeneity and Connectivity in Clastic Environments

    E-Print Network [OSTI]

    Hull, Thomas Frederick

    2011-10-21T23:59:59.000Z

    This study developed new concepts and interpretative methods for mapping reservoir heterogeneity and connectivity of a fault controlled Wilcox clastic reservoir in Texas, USA. The application of high-resolution seismic enhancement in this study...

  9. Ion implantation for figure correction of high-resolution x-ray telescope mirrors

    E-Print Network [OSTI]

    Chalifoux, Brandon D

    2014-01-01T23:59:59.000Z

    Fabricating mirrors for future high-resolution, large-aperture x-ray telescopes continues to challenge the x-ray astronomy instrumentation community. Building a large-aperture telescope requires thin, lightweight mirrors; ...

  10. Simultaneous computational discovery of DNA regulatory motifs and transcription factor binding constraints at high spatial resolution

    E-Print Network [OSTI]

    Guo, Yuchun

    2012-01-01T23:59:59.000Z

    I present three novel computational methods to address the challenge of identifying protein-DNA interactions at high spatial resolution from noisy ChIP-Seq data. I first present the genome positioning system (GPS) algorithm ...

  11. High-resolution quantification of groundwater flux using a heat tracer: laboratory sandbox tests

    E-Print Network [OSTI]

    Konetchy, Brant Evan

    2014-12-31T23:59:59.000Z

    Groundwater flux is the most critical factor controlling contaminant transport in aquifers. High-resolution information about groundwater flux and its variability is essential to properly assessing and remediating contamination sites. Recently, we...

  12. Coupling: Impact and Implications for High-Resolution Time-Lapse Seismic Surveying

    E-Print Network [OSTI]

    Walters, Shelby Lynn

    2008-07-28T23:59:59.000Z

    conditions with repeat shots has a different effect on surface waves and compressional waves. This observation has potential application to wavefield separation. Acquisition approaches typically used to optimize 2D or 3D high-resolution seismic surveys may...

  13. Results from the High-Resolution Fly's Eye (HiRes) Experiment

    E-Print Network [OSTI]

    Aspen 4/06/05 1 Results from the High-Resolution Fly's Eye (HiRes) Experiment Charles Jui (HiRes) University of Utah Physics at the End of the Galactic Cosmic Ray Spectrum Aspen Apr 26-30, 2005 #12;Aspen 4 · Anisotropy · Composition · Proton-air cross-section measurement #12;Aspen 4/06/05 3 The High Resolution Fly

  14. High Resolution Rydberg Spectroscopy of ultracold Rubidium Atoms

    E-Print Network [OSTI]

    Axel Grabowski; Rolf Heidemann; Robert Löw; Jürgen Stuhler; Tilman Pfau

    2005-08-10T23:59:59.000Z

    We present experiments on two-photon excitation of ${\\rm ^{87}}$Rb atoms to Rydberg states. For this purpose, two continuous-wave (cw)-laser systems for both 780 nm and 480 nm have been set up. These systems are optimized to a small linewidth (well below 1 MHz) to get both an efficient excitation process and good spectroscopic resolution. To test the performance of our laser system, we investigated the Stark splitting of Rydberg states. For n=40 we were able to see the hyperfine levels splitting in the electrical field for different finestructure states. To show the ability of spatially selective excitation to Rydberg states, we excited rubidium atoms in an electrical field gradient and investigated both linewidths and lineshifts. Furthermore we were able to excite the atoms selectively from the two hyperfine ground states to Rydberg states. Finally, we investigated the Autler-Townes splitting of the 5S$_{1/2}$$\\to$5P$_{3/2}$ transition via a Rydberg state to determine the Rabi frequency of this excitation step.

  15. Optic for an endoscope/borescope having high resolution and narrow field of view

    DOE Patents [OSTI]

    Stone, Gary F.; Trebes, James E.

    2003-10-28T23:59:59.000Z

    An optic having optimized high spatial resolution, minimal nonlinear magnification distortion while at the same time having a limited chromatic focal shift or chromatic aberrations. The optic located at the distal end of an endoscopic inspection tool permits a high resolution, narrow field of view image for medical diagnostic applications, compared to conventional optics for endoscopic instruments which provide a wide field of view, low resolution image. The image coverage is over a narrow (<20 degrees) field of view with very low optical distortion (<5% pin cushion or barrel distortion. The optic is also optimized for best color correction as well as to aid medical diagnostics.

  16. High-Resolution Residential Feeder Load Characterization and Variability Modelling

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville PowerCherries 82981-1cnHigh School football High School footballHigh-Pressure MOF Research

  17. Overshooting Convection from High-resolution NEXRAD Observations

    E-Print Network [OSTI]

    Solomon, David

    2014-01-09T23:59:59.000Z

    of the Rocky Mountains. Overshooting convection is most common over the high plains, and there is a pronounced seasonal and diurnal cycle present. The majority of overshooting systems occur during the warm season, and a diurnal maximum of overshooting occurs...

  18. 21T High Resolution Mass Accuracy Capability | EMSL

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    mass analyzer with co-located capabilities in high - throughput omics, imaging, and microfluidics. The 21T FTICR MS will be the best, if not the only, capability in the world to...

  19. Multi-Sensor Fusion of Electro-Optic and Infrared Signals for High Resolution Visible Images: Part II

    E-Print Network [OSTI]

    of high resolution and low noise level, but they cannot reflect information about the temperature the properties of low resolution and high noise level, but IR images can reflect information about temperature variation of objects in the daytime via high-resolution EO images. The proposed novel framework

  20. HIGH RESOLUTION SEDIMENT DYNAMICS IN SALT-WEDGE ESTUARIES

    E-Print Network [OSTI]

    Jay, David

    and Columbia River estuaries switch between two extremes of mixing on very small horizontal scales; over compared well with in situ settling tube observations, typically within a factor of 2. ACCOMPLISHMENTS arm of the Fraser River estuary (Figure 1). River flow during the study was very high, approximately

  1. HIGH RESOLUTION FORWARD AND INVERSE EARTHQUAKE MODELING ON TERASCALE COMPUTERS

    E-Print Network [OSTI]

    Shewchuk, Jonathan

    highly populated seismic region in the U.S., it has well- characterized geological structures (including in characterizing earthquake source and basin material properties, a critical remaining challenge is to invert basin geology and earthquake sources, and to use this capability to model and forecast strong ground

  2. High Resolution PV Power Modeling for Distribution Circuit Analysis

    SciTech Connect (OSTI)

    Norris, B. L.; Dise, J. H.

    2013-09-01T23:59:59.000Z

    NREL has contracted with Clean Power Research to provide 1-minute simulation datasets of PV systems located at three high penetration distribution feeders in the service territory of Southern California Edison (SCE): Porterville, Palmdale, and Fontana, California. The resulting PV simulations will be used to separately model the electrical circuits to determine the impacts of PV on circuit operations.

  3. A Cosmic Ray Test Platform Based on the High Time Resolution MRPC Technology

    E-Print Network [OSTI]

    Tianxiang Chen; Cheng Li; Yongjie Sun; Hongfang Chen; Ming Shao; Zebo Tang; Rongxing Yang; Yi Zhou; Yifei Zhang

    2015-03-13T23:59:59.000Z

    In order to test the performance of detector/prototype in environment of laboratory, we design and build a larger area ($90\\times52$ $cm^2$) test platform of cosmic ray based on well-designed Multi-gap Resistive Plate Chamber (MRPC) with an excellent time resolution and a high detection efficiency for the minimum ionizing particles (MIPs). The time resolution of the MRPC module used is tested to be ~80 ps, and the position resolution along the strip is ~5 mm, while the position resolution perpendicular to the strip is ~12.7 mm. The platform constructed by four MRPC modules can be functional for tracking the cosmic rays with a spatial resolution ~6.3 mm, and provide a reference time ~40 ps.

  4. High resolution PET breast imager with improved detection efficiency

    DOE Patents [OSTI]

    Majewski, Stanislaw

    2010-06-08T23:59:59.000Z

    A highly efficient PET breast imager for detecting lesions in the entire breast including those located close to the patient's chest wall. The breast imager includes a ring of imaging modules surrounding the imaged breast. Each imaging module includes a slant imaging light guide inserted between a gamma radiation sensor and a photodetector. The slant light guide permits the gamma radiation sensors to be placed in close proximity to the skin of the chest wall thereby extending the sensitive region of the imager to the base of the breast. Several types of photodetectors are proposed for use in the detector modules, with compact silicon photomultipliers as the preferred choice, due to its high compactness. The geometry of the detector heads and the arrangement of the detector ring significantly reduce dead regions thereby improving detection efficiency for lesions located close to the chest wall.

  5. LES Modeling of High Resolution Satellite Cloud Spatial and Thermal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville PowerCherries 82981-1cnHigh SchoolIn12electron 9 5 - -/e),,s - 1 2 3 4 5 6 7 8 9LDRD,LEDs:

  6. Sandia Energy - High-Resolution Computational Algorithms for Simulating

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Scienceand RequirementsCoatingsUltra-High-VoltagePower Company's (ORPC's) TidGen®

  7. High-Angular-Resolution Microbeam X-Ray Diffraction with CCD Detector

    SciTech Connect (OSTI)

    Imai, Yasuhiko; Kimura, Shigeru; Sakaia, Akira [Japan Synchrotron Radiation Research Institute, SPring-8, 1-1-1 Kouto, Sayo-cho, Sayo-gun, Hyogo 679-5198 (Japan); Sakata, Osami [Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama-cho, Toyonaka, Osaka 670-8531 (Japan)

    2010-04-06T23:59:59.000Z

    We have introduced a CCD-type two-dimensional X-ray detector for a microbeam X-ray diffraction system using synchrotron radiation, so that we can measure local reciprocal space maps (RSM) of samples rapidly. A local RSM of a strain-relaxed SiGe 004 grown on a Si (001) substrate was measured in higher-angular-resolution and faster than a conventional way. The measurement was achieved in 1 h 40 min. with the 2theta resolution of 80 murad and the spatial resolution of 1.4(h)x0.5(v) {mu}m{sup 2}. The introduction of the CCD enabled us to measure RSMs at many points in a sample, that is, the distribution of strain fields and lattice tilts can be revealed in high-angular- and high-spatial-resolution.

  8. High-resolution spectroscopic probes of collisions and half-collisions

    SciTech Connect (OSTI)

    Hall, G.E. [Brookhaven National Laboratory, Upton, NY (United States)

    1993-12-01T23:59:59.000Z

    Research in this program explores the dynamics of gas phase collisions and photodissociation by high-resolution laser spectroscopy. Simultaneous state and velocity detection frequently permits a determination of scalar or vector correlations among products. The correlated product distributions are always more informative, and often easier to interpret than the uncorrelated product state distributions. The authors have recently built an apparatus to record transient absorption spectra with 50 nS time resolution and 20 MHz frequency resolution using a single frequency Ti:sapphire laser. The photodissociation of NCCN and C{sub 2}H{sub 5}SCN at 193 nm is discussed.

  9. A High-resolution Spectrum of the R CrB Star V2552 Ophiuchi

    E-Print Network [OSTI]

    N. Kameswara Rao; David L. Lambert

    2003-08-25T23:59:59.000Z

    Photometry and low-resolution spectroscopy have added V2552 Oph to the rare class of R Coronae Borealis variables. We confirm this classification of V2552 Oph through a comparison of our high-resolution optical spectrum of this star and that of R CrB and other F-type members of the class. We show that V2552 Oph most closely resembles Y Mus and FH Sct, stars in which Sr, Y, and Zr are enhanced.

  10. Dedicated mobile high resolution prostate PET imager with an insertable transrectal probe

    DOE Patents [OSTI]

    Majewski, Stanislaw (Yorktown, VA); Proffitt, James (Newport News, VA)

    2010-12-28T23:59:59.000Z

    A dedicated mobile PET imaging system to image the prostate and surrounding organs. The imaging system includes an outside high resolution PET imager placed close to the patient's torso and an insertable and compact transrectal probe that is placed in close proximity to the prostate and operates in conjunction with the outside imager. The two detector systems are spatially co-registered to each other. The outside imager is mounted on an open rotating gantry to provide torso-wide 3D images of the prostate and surrounding tissue and organs. The insertable probe provides closer imaging, high sensitivity, and very high resolution predominately 2D view of the prostate and immediate surroundings. The probe is operated in conjunction with the outside imager and a fast data acquisition system to provide very high resolution reconstruction of the prostate and surrounding tissue and organs.

  11. High resolution x-ray and gamma ray imaging using diffraction lenses with mechanically bent crystals

    DOE Patents [OSTI]

    Smither, Robert K. (Hinsdale, IL)

    2008-12-23T23:59:59.000Z

    A method for high spatial resolution imaging of a plurality of sources of x-ray and gamma-ray radiation is provided. High quality mechanically bent diffracting crystals of 0.1 mm radial width are used for focusing the radiation and directing the radiation to an array of detectors which is used for analyzing their addition to collect data as to the location of the source of radiation. A computer is used for converting the data to an image. The invention also provides for the use of a multi-component high resolution detector array and for narrow source and detector apertures.

  12. High resolution 3D insider detection and tracking.

    SciTech Connect (OSTI)

    Nelson, Cynthia Lee

    2003-09-01T23:59:59.000Z

    Vulnerability analysis studies show that one of the worst threats against a facility is that of an active insider during an emergency evacuation. When a criticality or other emergency alarm occurs, employees immediately proceed along evacuation routes to designated areas. Procedures are then implemented to account for all material, classified parts, etc. The 3-Dimensional Video Motion Detection (3DVMD) technology could be used to detect and track possible insider activities during alarm situations, as just described, as well as during normal operating conditions. The 3DVMD technology uses multiple cameras to create 3-dimensional detection volumes or zones. Movement throughout detection zones is tracked and high-level information, such as the number of people and their direction of motion, is extracted. In the described alarm scenario, deviances of evacuation procedures taken by an individual could be immediately detected and relayed to a central alarm station. The insider could be tracked and any protected items removed from the area could be flagged. The 3DVMD technology could also be used to monitor such items as machines that are used to build classified parts. During an alarm, detections could be made if items were removed from the machine. Overall, the use of 3DVMD technology during emergency evacuations would help to prevent the loss of classified items and would speed recovery from emergency situations. Further security could also be added by analyzing tracked behavior (motion) as it corresponds to predicted behavior, e.g., behavior corresponding with the execution of required procedures. This information would be valuable for detecting a possible insider not only during emergency situations, but also during times of normal operation.

  13. Hurricane Wind Field Estimation from SeaWinds at Ultra High Resolution

    E-Print Network [OSTI]

    Long, David G.

    Hurricane Wind Field Estimation from SeaWinds at Ultra High Resolution Brent A. Williams and David) are inherently noisier than the standard 25km products and the high rain rates often associated with hurricanes. This paper develops a new procedure for hurricane wind field estimation from the SeaWinds instrument at ultra

  14. High-resolution 18F-FDG PET with MRI for monitoring response to treatment in rheumatoid arthritis

    E-Print Network [OSTI]

    2010-01-01T23:59:59.000Z

    of a dedicated breast PET/CT scanner during human imaging. Jhigh-resolution 18 F-FDG PET images (pseudocolor) overlaidMONTH High-resolution 18 F-FDG PET with MRI for monitoring

  15. Differential high-resolution stimulated CW Raman spectroscopy of hydrogen in a hollow-core fiber

    E-Print Network [OSTI]

    Westergaard, Philip G; Petersen, Jan C

    2015-01-01T23:59:59.000Z

    We demonstrate sensitive high-resolution stimulated Raman measurements of hydrogen using a hollow-core photonic crystal fiber (HC-PCF). The Raman transition is pumped by a narrow linewidth (<50 kHz) 1064 nm continuous-wave (CW) fiber laser. The probe light is produced by a homebuilt CW optical parametric oscillator (OPO), tunable from around 800 nm to 1300 nm (linewidth ~ 5 MHz). These narrow linewidth lasers allow for an excellent spectral resolution of approximately 10^-4 cm^(-1). The setup employs a differential measurement technique for noise rejection in the probe beam, which also eliminates background signals from the fiber. With the high sensitivity obtained, Raman signals were observed with only a few mW of optical power in both the pump and probe beams. This demonstration allows for high resolution Raman identification of molecules and quantification of Raman signal strengths.

  16. Hadronic energy resolution of a highly granular scintillator-steel hadron calorimeter using software compensation techniques

    E-Print Network [OSTI]

    CALICE Collaboration; C. Adloff; J. Blaha; J. -J. Blaising; C. Drancourt; A. Espargilière; R. Gaglione; N. Geffroy; Y. Karyotakis; J. Prast; G. Vouters; K. Francis; J. Repond; J. Smith; L. Xia; E. Baldolemar; J. Li; S. T. Park; M. Sosebee; A. P. White; J. Yu; T. Buanes; G. Eigen; Y. Mikami; N. K. Watson; T. Goto; G. Mavromanolakis; M. A. Thomson; D. R. Ward; W. Yan; D. Benchekroun; A. Hoummada; Y. Khoulaki; M. Benyamna; C. Cârloganu; F. Fehr; P. Gay; S. Manen; L. Royer; G. C. Blazey; A. Dyshkant; J. G. R. Lima; V. Zutshi; J. -Y. Hostachy; L. Morin; U. Cornett; D. David; G. Falley; K. Gadow; P. Göttlicher; C. Günter; B. Hermberg; S. Karstensen; F. Krivan; A. -I. Lucaci-Timoce; S. Lu; B. Lutz; S. Morozov; V. Morgunov; M. Reinecke; F. Sefkow; P. Smirnov; M. Terwort; A. Vargas-Trevino; N. Feege; E. Garutti; I. Marchesini; M. Ramilli; P. Eckert; T. Harion; A. Kaplan; H. -Ch. Schultz-Coulon; W. Shen; R. Stamen; A. Tadday; B. Bilki; E. Norbeck; Y. Onel; G. W. Wilson; K. Kawagoe; P. D. Dauncey; A. -M. Magnan; M. Wing; F. Salvatore; E. Calvo Alamillo; M. -C. Fouz; J. Puerta-Pelayo; V. Balagura; B. Bobchenko; M. Chadeeva; M. Danilov; A. Epifantsev; O. Markin; R. Mizuk; E. Novikov; V. Rusinov; E. Tarkovsky; N. Kirikova; V. Kozlov; P. Smirnov; Y. Soloviev; P. Buzhan; B. Dolgoshein; A. Ilyin; V. Kantserov; V. Kaplin; A. Karakash; E. Popova; S. Smirnov; C. Kiesling; S. Pfau; K. Seidel; F. Simon; C. Soldner; M. Szalay; M. Tesar; L. Weuste; J. Bonis; B. Bouquet; S. Callier; P. Cornebise; Ph. Doublet; F. Dulucq; M. Faucci Giannelli; J. Fleury; H. Li; G. Martin-Chassard; F. Richard; Ch. de la Taille; R. Pöschl; L. Raux; N. Seguin-Moreau; F. Wicek; M. Anduze; V. Boudry; J-C. Brient; D. Jeans; P. Mora de Freitas; G. Musat; M. Reinhard; M. Ruan; H. Videau; B. Bulanek; J. Zacek; J. Cvach; P. Gallus; M. Havranek; M. Janata; J. Kvasnicka; D. Lednicky; M. Marcisovsky; I. Polak; J. Popule; L. Tomasek; M. Tomasek; P. Ruzicka; P. Sicho; J. Smolik; V. Vrba; J. Zalesak; B. Belhorma; H. Ghazlane; T. Takeshita; S. Uozumi; J. Sauer; S. Weber; C. Zeitnitz

    2012-09-27T23:59:59.000Z

    The energy resolution of a highly granular 1 m3 analogue scintillator-steel hadronic calorimeter is studied using charged pions with energies from 10 GeV to 80 GeV at the CERN SPS. The energy resolution for single hadrons is determined to be approximately 58%/sqrt(E/GeV}. This resolution is improved to approximately 45%/sqrt(E/GeV) with software compensation techniques. These techniques take advantage of the event-by-event information about the substructure of hadronic showers which is provided by the imaging capabilities of the calorimeter. The energy reconstruction is improved either with corrections based on the local energy density or by applying a single correction factor to the event energy sum derived from a global measure of the shower energy density. The application of the compensation algorithms to Geant4 simulations yield resolution improvements comparable to those observed for real data.

  17. X-ray Observations of Galaxies: The Importance of Deep High-Resolution Observations

    E-Print Network [OSTI]

    G. Fabbiano

    2007-11-30T23:59:59.000Z

    X-ray observations of galaxies have grown from a curiosity into a full-fledged field of astronomy. These observations provide unique information on black holes, binary stars, and the hot phase of the ISM, which can be used to constrain the chemical evolution of the Universe, and the joint evolution of galaxies and massive black holes. These exciting results are due in large part to the high-resolution capability of {\\it Chandra}. To follow on {\\it Chandra} and push forward this science past the present capabilities, our community must build a high-resolution (sub-arcsecond) large-area (several square meters) X-ray telescope.

  18. High resolution Cerenkov light imaging of induced positron distribution in proton therapy

    SciTech Connect (OSTI)

    Yamamoto, Seiichi, E-mail: s-yama@met.nagoya-u.ac.jp; Fujii, Kento; Morishita, Yuki; Okumura, Satoshi; Komori, Masataka [Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Aichi 461-8673 (Japan); Toshito, Toshiyuki [Department of Proton Therapy Physics, Nagoya Proton Therapy Center, Nagoya City West Medical Center, Aichi 462-8508 (Japan)

    2014-11-01T23:59:59.000Z

    Purpose: In proton therapy, imaging of the positron distribution produced by fragmentation during or soon after proton irradiation is a useful method to monitor the proton range. Although positron emission tomography (PET) is typically used for this imaging, its spatial resolution is limited. Cerenkov light imaging is a new molecular imaging technology that detects the visible photons that are produced from high-speed electrons using a high sensitivity optical camera. Because its inherent spatial resolution is much higher than PET, the authors can measure more precise information of the proton-induced positron distribution with Cerenkov light imaging technology. For this purpose, they conducted Cerenkov light imaging of induced positron distribution in proton therapy. Methods: First, the authors evaluated the spatial resolution of our Cerenkov light imaging system with a {sup 22}Na point source for the actual imaging setup. Then the transparent acrylic phantoms (100 × 100 × 100 mm{sup 3}) were irradiated with two different proton energies using a spot scanning proton therapy system. Cerenkov light imaging of each phantom was conducted using a high sensitivity electron multiplied charge coupled device (EM-CCD) camera. Results: The Cerenkov light’s spatial resolution for the setup was 0.76 ± 0.6 mm FWHM. They obtained high resolution Cerenkov light images of the positron distributions in the phantoms for two different proton energies and made fused images of the reference images and the Cerenkov light images. The depths of the positron distribution in the phantoms from the Cerenkov light images were almost identical to the simulation results. The decay curves derived from the region-of-interests (ROIs) set on the Cerenkov light images revealed that Cerenkov light images can be used for estimating the half-life of the radionuclide components of positrons. Conclusions: High resolution Cerenkov light imaging of proton-induced positron distribution was possible. The authors conclude that Cerenkov light imaging of proton-induced positron is promising for proton therapy.

  19. A High Resolution, Light-Weight, Synthetic Aperture Radar for UAV Application

    SciTech Connect (OSTI)

    Doerry, A.W.; Hensley, W.H.; Stence, J.; Tsunoda, S.I. Pace, F.; Walker, B,C.; Woodring, M.

    1999-05-27T23:59:59.000Z

    (U) Sandia National Laboratories in collaboration with General Atomics (GA) has designed and built a high resolution, light-weight, Ku-band Synthetic Aperture Radar (SAR) known as "Lynx". Although Lynx can be operated on a wide variety of manned and unmanned platforms, its design is optimized for use on medium altitude Unmanned Aerial Vehicles (UAVS). In particular, it can be operated on the Predator, I-GNAT, and Prowler II platforms manufactured by GA. (U) The radar production weight is less than 120 lb and operates within a 3 GHz band from 15.2 GHz to 18.2 GHz with a peak output power of 320 W. Operating range is resolution and mode dependent but can exceed 45 km in adverse weather (4 mm/hr rain). Lynx has operator selectable resolution and is capable of 0.1 m resolution in spotlight mode and 0.3 m resolution in stripmap mode, over substantial depression angles (5 to 60 deg) and squint angles (broadside ±45 deg). Real-time Motion Compensation is implemented to allow high-quality image formation even during vehicle turns and other maneuvers.

  20. High-Resolution 3 T MR Microscopy Imaging of Arterial Walls

    SciTech Connect (OSTI)

    Sailer, Johannes, E-mail: johannes.sailer@univie.ac.at; Rand, Thomas [University of Vienna, Department of Angiography and Interventional Radiology (Austria); Berg, Andreas [University of Vienna, Institute for Medical Physics (Austria); Sulzbacher, Irene [University of Vienna, Clinical Institute of Pathology (Austria); Peloschek, P. [University of Vienna, Department of Angiography and Interventional Radiology (Austria); Hoelzenbein, Thomas [University of Vienna, Department of Surgery (Austria); Lammer, Johannes [University of Vienna, Department of Angiography and Interventional Radiology (Austria)

    2006-10-15T23:59:59.000Z

    Purpose. To achieve a high spatial resolution in MR imaging that allows for clear visualization of anatomy and even histology and documentation of plaque morphology in in vitro samples from patients with advanced atherosclerosis. A further objective of our study was to evaluate whether T2-weighted high-resolution MR imaging can provide accurate classification of atherosclerotic plaque according to a modified American Heart Association classification. Methods. T2-weighted images of arteries were obtained in 13 in vitro specimens using a 3 T MR unit (Medspec 300 Avance/Bruker, Ettlingen, Germany) combined with a dedicated MR microscopy system. Measurement parameters were: T2-weighted sequences with TR 3.5 sec, TE 15-120 msec; field of view (FOV) 1.4 x 1.4; NEX 8; matrix 192; and slice thickness 600 {mu}m. MR measurements were compared with corresponding histologic sections. Results. We achieved excellent spatial and contrast resolution in all specimens. We found high agreement between MR images and histology with regard to the morphology and extent of intimal proliferations in all but 2 specimens. We could differentiate fibrous caps and calcifications from lipid plaque components based on differences in signal intensity in order to differentiate hard and soft atheromatous plaques. Hard plaques with predominantly intimal calcifications were found in 7 specimens, and soft plaques with a cholesterol/lipid content in 5 cases. In all specimens, hemorrhage or thrombus formation, and fibrotic and hyalinized tissue could be detected on both MR imaging and histopathology. Conclusion. High-resolution, high-field MR imaging of arterial walls demonstrates the morphologic features, volume, and extent of intimal proliferations with high spatial and contrast resolution in in vitro specimens and can differentiate hard and soft plaques.

  1. Energy Resolved High Resolution Dynamic E-Cell Materials Research. Final Report

    SciTech Connect (OSTI)

    Carpenter, Ray; Sharma, Renu; Mayer, James

    2000-05-16T23:59:59.000Z

    The purpose of this project was to develop in situ materials reaction observation capability in an intermediate voltage high resolution transmission electron microscope. To accomplish this we purchased a GATAN imaging energy filter system, a hot stage, and designed and constructed an environmental cell and real time television image recording system, and installed this equipment on our EM 430 intermediate voltage electron microscope.

  2. HIGH-RESOLUTION MID-INFRARED SPECTROSCOPY OF ULTRALUMINOUS INFRARED GALAXIES D. Farrah,1

    E-Print Network [OSTI]

    Galis, Frietson

    infrared emission. This initially provoked heated debate between a ``starburst'' camp and an ``activeHIGH-RESOLUTION MID-INFRARED SPECTROSCOPY OF ULTRALUMINOUS INFRARED GALAXIES D. Farrah,1 J. Bernard, 10Y37 m spectra of 53 ultraluminous infrared galaxies (ULIRGs), taken using the Infrared Spectrograph

  3. High Resolution Sharp Computational Methods for Elliptic and Parabolic Problems in Complex Geometries

    E-Print Network [OSTI]

    Fedkiw, Ron

    High Resolution Sharp Computational Methods for Elliptic and Parabolic Problems in Complex Geometries Frédéric Gibou Chohong Min Ron Fedkiw November 2, 2012 In honor of Stan Osher's 70th birthday of chemical species (see [48] and the references therein); they are also core building blocks in fields

  4. A Comparison of Hurricane Eye Determination Using Standard and Ultra-High Resolution

    E-Print Network [OSTI]

    Long, David G.

    A Comparison of Hurricane Eye Determination Using Standard and Ultra-High Resolution QuikSCAT Winds of hurricanes. I. INTRODUCTION Space-borne scatterometers such as SeaWinds on QuikSCAT are instruments designed these is the observation and tracking of tropical cyclones including hurricanes. Several fea- tures of interest

  5. Scene Reconstruction from High Spatio-Angular Resolution Light Fields Changil Kim1,2

    E-Print Network [OSTI]

    Zimmer, Henning

    Scene Reconstruction from High Spatio-Angular Resolution Light Fields Changil Kim1,2 Henning Zimmer Figure 1: Our method reconstructs accurate depth from light fields of complex scenes. The images on the left show a 2D slice of a 3D input light field, a so called epipolar-plane image (EPI), and two out

  6. Noninvasive high-resolution detection of the arterial and venous input function through a PET Wrist

    E-Print Network [OSTI]

    Noninvasive high-resolution detection of the arterial and venous input function through a PET Wrist using planar coincidence images. I. INTRODUCTION Quantitative Positron Emission Tomography (PET) often determine the input function. These techniques include external monitors and PET scanners that measure

  7. Compact, High-Resolution, Multi-Layer Semiconductor PET Detector Module

    E-Print Network [OSTI]

    Ohta, Shigemi

    Compact, High-Resolution, Multi-Layer Semiconductor PET Detector Module Summary Multi tomography (PET) systems, but the conventional electrodes used require a prohibitive number of readout channels. Now, a breakthrough compact PET detector offers a specialized configuration of cross strip

  8. 2D and 3D high-resolution imaging to reconstruct the microstructure of clay media

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    2D and 3D high-resolution imaging to reconstruct the microstructure of clay media J.C. Robinet1 & S compacted clay (illite) system, considered to be an analogy for the clay matrix constituting clay-rocks, and three different clayrocks (Callovo-Oxfordian argilites (FR), Opalinus Clay (CH), Boom Clay (BE)). Part

  9. CLASSIFICATION OF BIOMEDICAL HIGH-RESOLUTION MICRO-CT IMAGES FOR DIRECT VOLUME RENDERING

    E-Print Network [OSTI]

    López-Sánchez, Maite

    CLASSIFICATION OF BIOMEDICAL HIGH-RESOLUTION MICRO-CT IMAGES FOR DIRECT VOLUME RENDERING Maite L,cerquide,davidm,anna}@maia.ub.es ABSTRACT This paper introduces a machine learning approach into the process of direct volume rendering that generates the classification func- tion within the optical property function used for rendering. Briefly

  10. Calibration of sclerosponge oxygen isotope records to temperature using high-resolution d18

    E-Print Network [OSTI]

    Miami, University of

    Calibration of sclerosponge oxygen isotope records to temperature using high-resolution d18 O data; available online 21 May 2009 Abstract A revised calibration is presented relating the oxygen isotope an existing calibration which was determined using measurements of salinity rather than directly measured d18

  11. Role of pseudospin in quasiparticle interferences in epitaxial probed by high resolution scanning tunneling microscopy

    E-Print Network [OSTI]

    Boyer, Edmond

    Role of pseudospin in quasiparticle interferences in epitaxial graphene, probed by high resolution of freedom emerging in graphene as a direct consequence of its honeycomb atomic structure, is responsible to provide a clear understanding of how such graphene's pseudospin impacts the quasiparticle interferences

  12. Increasing the Scalability of PISM for High Resolution Ice Sheet Models Phillip Dickens

    E-Print Network [OSTI]

    Dickens, Phillip M.

    Increasing the Scalability of PISM for High Resolution Ice Sheet Models Phillip Dickens School at large. One important piece of the climate puzzle is how the dynamics of large-scale ice sheets developed several simulation models to predict and understand the behavior of large-scale ice sheets

  13. High resolution spectroscopic characterization of the FGK stars in the Solar neighbourhood

    E-Print Network [OSTI]

    Complutense de Madrid, Universidad

    the EW #12;FIGURE 1. Left panel: EW Li I vs. (B-V). Different colors and symbols are used for stars). The obtained values are plotted in the EW(Li I) vs. spectral type diagram in Fig. 1 (left panel). ComparingHigh resolution spectroscopic characterization of the FGK stars in the Solar neighbourhood R. M

  14. Induction Machine Fault Detection Enhancement Using a Stator Current High Resolution Spectrum

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    into stator winding short circuit, broken rotor bar, broken end-ring, rotor eccentricity, bearing faultsInduction Machine Fault Detection Enhancement Using a Stator Current High Resolution Spectrum El-Fault detection in squirrel cage induction machines based on stator current spectrum has been widely investi gated

  15. ElectroMagnetic Radiations of FPGAs: High Spatial Resolution Cartography and Attack of a

    E-Print Network [OSTI]

    Boyer, Edmond

    ElectroMagnetic Radiations of FPGAs: High Spatial Resolution Cartography and Attack, a "root of trust" must be defined, insulated and then carefully protected. Until very recently, this role agencies) have tackled the issue of protecting ASICs from side-channel attacks (SCAs). In the meantime

  16. A ber-optic based calibration system for the High Resolution Fly's Eye

    E-Print Network [OSTI]

    A ber-optic based calibration system for the High Resolution Fly's Eye cosmic ray observatory J, 800 Yale Blvd NE, Albuquerque, NM 87131-1156 Abstract This article describes the ber-optic based: Highest energy cosmic rays Fly's Eye Experiment HiRes YAG Laser Fiber-optics PMT PACS: 95.45.+i 95.85.Ls

  17. Virtually distortion-free imaging system for large field, high resolution lithography

    DOE Patents [OSTI]

    Hawryluk, A.M.; Ceglio, N.M.

    1993-01-05T23:59:59.000Z

    Virtually distortion free large field high resolution imaging is performed using an imaging system which contains large field distortion or field curvature. A reticle is imaged in one direction through the optical system to form an encoded mask. The encoded mask is then imaged back through the imaging system onto a wafer positioned at the reticle position.

  18. Isolation of transport mechanisms in PEFCs using high resolution neutron imaging

    E-Print Network [OSTI]

    Mench, Matthew M.

    imaging has developed into an important tool for fuel cell diagnostics over the past six years. The advent November 2013 Accepted 2 December 2013 Available online xxx Keywords: Proton exchange membrane fuel cell profiles were determined using high resolution neutron radiog- raphy for commercially available fuel cell

  19. PROGRESS TOWARDS A HIGH-RESOLUTION RETINAL PROSTHESIS James D. Weiland1

    E-Print Network [OSTI]

    Arizona, University of

    PROGRESS TOWARDS A HIGH-RESOLUTION RETINAL PROSTHESIS James D. Weiland1 , Wolfgang Fink2,1 , Mark, and stimulating electrodes. Keywords ­ retinal prosthesis, microsystems, electrical stimulation, neural prostheses year.[1] One proposed treatment for these conditions is a retinal prosthesis that will stimulate

  20. 3 July 2003 HIRES3D -ITC Research Seminar -Robert Hack 1 HIGH RESOLUTION REMOTE SENSING

    E-Print Network [OSTI]

    Hack, Robert

    3 July 2003 HIRES3D - ITC Research Seminar - Robert Hack 1 HIRES3D HIGH RESOLUTION REMOTE SENSING FOR 3D GROUND MODELING AND CLASSIFICATION ITC Research Seminar, 3 July 2003 Robert Hack International Institute for Geoinformation Sciences and Earth Observation (ITC) #12;3 July 2003 HIRES3D - ITC Research

  1. North Brazil Current rings and transport of southern waters in a high resolution numerical

    E-Print Network [OSTI]

    North Brazil Current rings and transport of southern waters in a high resolution numerical of the North Brazil Current (NBC) retroflection and North Brazil Current rings. The model mean and seasonal circulation feature near the western boundary is the North Brazil Current (NBC), which has sources

  2. High-resolution velocity field imaging around a borehole: Excavation Damaged Zone characterization

    E-Print Network [OSTI]

    Boyer, Edmond

    .balland@ineris.fr, vincent.renaud@ineris.fr ABSTRACT The excavation of a deep underground structure induces a stress field of a material. In the case of underground storage, rock damage will affect the rock capacity to confine1 High-resolution velocity field imaging around a borehole: Excavation Damaged Zone

  3. TOWARDS AN IMPROVED HIGH RESOLUTION GLOBAL LONG-TERM SOLAR RESOURCE DATABASE

    E-Print Network [OSTI]

    Perez, Richard R.

    TOWARDS AN IMPROVED HIGH RESOLUTION GLOBAL LONG- TERM SOLAR RESOURCE DATABASE Paul W. Stackhouse 80401 251 Fuller Road david.renne@nrel.gov Albany, NY 12203 perez@asrc.cestm.albany.edu John Bates.knapp@noaa.gov ABSTRACT This paper presents an overview of an ongoing project to develop and deliver a solar mapping

  4. High Resolution SAR Interferometry: influence of local topography in the context of glacier monitoring

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    High Resolution SAR Interferometry: influence of local topography in the context of glacier the opportu- nity to measure temperate glacier surface topography and displacement between the two for glacier activity monitoring, by providing regular measure- ments such as surface topography, velocity

  5. Net accumulation of the Greenland ice sheet: High resolution modeling of climate changes

    E-Print Network [OSTI]

    Born, Andreas

    : Kiilsholm, S., J. H. Christensen, K. Dethloff, and A. Rinke, Net accumulation of the Greenland ice sheetNet accumulation of the Greenland ice sheet: High resolution modeling of climate changes Sissi, Denmark Klaus Dethloff and Annette Rinke Alfred Wegener Institute for Polar and Marine Research

  6. High spatial resolution subsurface thermal emission microscopy S. B. Ippolito,a)

    E-Print Network [OSTI]

    a total optical power proportional to its absolute temperature to the fourth power. An object that hasHigh spatial resolution subsurface thermal emission microscopy S. B. Ippolito,a) S. A. Thorne, M. G increasing lens technique to subsurface thermal emission microscopy of Si integrated circuits. We achieve

  7. A High Resolution Intergalactic Explorer for the Soft X-ray/FUV

    E-Print Network [OSTI]

    Martin Elvis; Fabrizio Fiore; the CWE Team

    2003-03-19T23:59:59.000Z

    We present a mission concept for high resolution X-ray spectroscopy with a resolving power, R~6000, (c.f. R=Web'. The Cosmic Web is predicted to contain most of the normal matter (baryons) in the nearby Universe.

  8. High spatial resolution X-ray and gamma ray imaging system using diffraction crystals

    DOE Patents [OSTI]

    Smither, Robert K. (Hinsdale, IL)

    2011-05-17T23:59:59.000Z

    A method and a device for high spatial resolution imaging of a plurality of sources of x-ray and gamma-ray radiation are provided. The device comprises a plurality of arrays, with each array comprising a plurality of elements comprising a first collimator, a diffracting crystal, a second collimator, and a detector.

  9. Exploration of Weather Impacts on Freeway Traffic Operations and Safety Using High-Resolution Weather Data

    E-Print Network [OSTI]

    Bertini, Robert L.

    Exploration of Weather Impacts on Freeway Traffic Operations and Safety Using High-Resolution Weather Data by Chengyu Dai A thesis submitted in partial fulfillment of the requirements for the degree Moradkhani Kristin Tufte Portland State University ©2011 #12;i ABSTRACT Adverse weather is considered as one

  10. HighResolution Numerical Methods for MicellarPolymer Flooding and Surfactant Enhanced Aquifer Remediation

    E-Print Network [OSTI]

    Trangenstein, John A.

    been used to study the micellar­ polymer flooding process in enhanced oil recovery [12], [18], [19 in practical im­ plementation of enhanced oil recovery techniques at this time, there is increasing interestHigh­Resolution Numerical Methods for Micellar­Polymer Flooding and Surfactant Enhanced Aquifer

  11. High resolution RCM simulation of eastern Mediterranean climate and its expected changes to 2050

    E-Print Network [OSTI]

    Adler, Joan

    High resolution RCM simulation of eastern Mediterranean climate and its expected changes to 2050. Modern global climate change evaluations usually based on application of coupled atmosphere-ocean global by the Intergovernmental Panel on Climate Change (IPCC). A number of different anthropogenic emission scenarios have been

  12. High-resolution population grids and future scenarios for Tanzania Philip J. Platts & Ruth D. Swetnam

    E-Print Network [OSTI]

    Marchant, Rob

    this grid and the LandScan grid to remove all persons from these protected areas (Single Map Algebra Tool1 High-resolution population grids and future scenarios for Tanzania Philip J. Platts & Ruth D, were obtained by hindcasting the LandScan grid on a ward-by-ward basis, such that ward totals matched

  13. A high-resolution mapped grid algorithm for compressible multiphase flow problems

    E-Print Network [OSTI]

    Shyue, Keh-Ming

    A high-resolution mapped grid algorithm for compressible multiphase flow problems K.-M. Shyue 18 August 2010 Keywords: Compressible multiphase flow Fluid-mixture model Mapped grids Wave-propagation method Stiffened gas equation of state a b s t r a c t We describe a simple mapped-grid approach

  14. Estimating quality factor and mean grain size of sediments from high-resolution marine seismic data

    E-Print Network [OSTI]

    National Oceanography Centre Southampton

    model of quality factor against mean grain size from published sediment studies, the mean grain sizes with frequency. The Biot-Stoll model shows a marked velocity dispersion and nonlinear transition in compressionalEstimating quality factor and mean grain size of sediments from high-resolution marine seismic data

  15. High-resolution chemical imaging of gold nanoparticles using hard x-ray ptychography

    SciTech Connect (OSTI)

    Hoppe, R.; Patommel, J.; Schroer, C. G. [Institute of Structural Physics, Technische Universitaet Dresden, D-01062 Dresden (Germany)] [Institute of Structural Physics, Technische Universitaet Dresden, D-01062 Dresden (Germany); Reinhardt, J. [Institute of Structural Physics, Technische Universitaet Dresden, D-01062 Dresden (Germany) [Institute of Structural Physics, Technische Universitaet Dresden, D-01062 Dresden (Germany); Deutsches Elektronen-Synchrotron DESY, D-22607 Hamburg (Germany)] [Germany; Hofmann, G.; Grunwaldt, J.-D. [Institute for Chemical Technology and Polymer Chemistry, Karlsruhe Institute of Technology, D-76131 Karlsruhe (Germany)] [Institute for Chemical Technology and Polymer Chemistry, Karlsruhe Institute of Technology, D-76131 Karlsruhe (Germany); Damsgaard, C. D. [Center for Electron Nanoscopy and Department of Physics, Technical University of Denmark, DK-2800 Lyngby (Denmark)] [Center for Electron Nanoscopy and Department of Physics, Technical University of Denmark, DK-2800 Lyngby (Denmark); Wellenreuther, G.; Falkenberg, G. [Deutsches Elektronen-Synchrotron DESY, D-22607 Hamburg (Germany)] [Deutsches Elektronen-Synchrotron DESY, D-22607 Hamburg (Germany)

    2013-05-20T23:59:59.000Z

    We combine resonant scattering with (ptychographic) scanning coherent diffraction microscopy to determine the chemical state of gold nanoparticles with high spatial resolution. Ptychographic images of the sample are recorded for a series of energies around the gold L{sub 3} absorption edge. From these data, chemical information in the form of absorption and resonant scattering spectra is reconstructed at each location in the sample. For gold nanoparticles of about 100 nm diameter, a spatial resolution of about 20-30 nm is obtained. In the future, this microscopy approach will open the way to operando studies of heterogeneous catalysts on the nanometer scale.

  16. Gas Dynamics in the Barred Seyfert Galaxy NGC4151 - II. High Resolution HI Study

    E-Print Network [OSTI]

    C. G. Mundell; A. Pedlar; D. L. Shone; A. Robinson

    1998-12-09T23:59:59.000Z

    We present sensitive, high angular resolution (6" x 5") 21-cm observations of the neutral hydrogen in the nearby barred Seyfert galaxy, NGC4151. These HI observations, obtained using the VLA in B-configuration, are the highest resolution to date of this galaxy, and reveal hitherto unprecedented detail in the distribution and kinematics of the HI on sub-kiloparsec scales. A complete analysis and discussion of the HI data are presented and the global properties of the galaxy are related to the bar dynamics presented in Paper I.

  17. High Resolution BPM Upgrade for the ATF Damping Ring at KEK

    E-Print Network [OSTI]

    Eddy, N; Fellenz, B; Gianfelice-Wendt, E; Prieto, P; Rechenmacher, R; Semenov, A; Voy, D; Wendt, M; Zhang, D; Terunuma, N; Urakawa, J

    2012-01-01T23:59:59.000Z

    A beam position monitor (BPM) upgrade at the KEK Accelerator Test Facility (ATF) damping ring has been accomplished, carried out by a KEK/FNAL/SLAC collaboration under the umbrella of the global ILC R&D effort. The upgrade consists of a high resolution, high reproducibility read-out system, based on analog and processing, and also implements a new automatic gain error correction schema. The technical concept and realization as well as results of beam studies are presented.

  18. Visual Comfort Analysis of Innovative Interior and Exterior Shading Systems for Commercial Buildings using High Resolution Luminance Images

    E-Print Network [OSTI]

    Konis, Kyle

    2011-01-01T23:59:59.000Z

    Society of North America. Luminance ratio limits; ch. 11,range photography as a luminance mapping Technique. Lawrenceusing High Resolution Luminance Images Kyle Konis Lawrence

  19. High resolution neutron crystallographic studies of the hydration of coenzyme cob(II)alamin

    SciTech Connect (OSTI)

    Jogl, Gerwald [Brown University; Wang, Xiaoping [ORNL; Mason, Sax [Institut Laue-Langevin (ILL); Kovalevsky, Andrey [Los Alamos National Laboratory (LANL); Mustyakimov, Marat [Los Alamos National Laboratory (LANL); Fisher, Zoe [Los Alamos National Laboratory (LANL); Hoffmann, Christina [ORNL; Kratky, Christoph [Institute of Biosciences, University of Graz; Langan, Paul [ORNL

    2011-01-01T23:59:59.000Z

    The hydration of coenzyme cob(II)alamin has been studied using high resolution monochromatic neutron crystallographic data collected at room temperature to a resolution of surrounded by flexible side chains with terminal functional groups may be significant for 0.92 on the original diffractometer D19 with a prototype 4o x 64o detector at the high-flux reactor neutron source run by the Institute Laue Langevin. The resulting structure provides H bonding parameters for the hydration of biomacromolecules to unprecedented accuracy. These experimental parameters will be used to define more accurate force-fields for biomacromolecular structure refinement. The presence of a hydrophobic bowl motif efficient scavenging of ligands. The feasibility of extending the resolution of this structure to ultra high resolution was investigated by collecting time-of-flight neutron crystallographic data on diffractometer TOPAZ with a prototype array of 14 modular 21o x 21o detectors at the Spallation Neutron Source run by Oak Ridge National Laboratory.

  20. A High-resolution TOF Detector _ A Possible Way to Compete with a RICH Detector

    SciTech Connect (OSTI)

    Va'vra, J; /SLAC; Ertley, C.; /Argonne; Leith, D.W.G.S.; Ratcliff, B.; Schwiening, J.; /SLAC

    2008-07-25T23:59:59.000Z

    Using two identical 64-pixel Burle/Photonis MCP-PMTs to provide start and stop signals, they have achieved a timing resolution of {sigma}{sub Single{_}detector} {approx} 7.2 ps for N{sub pe} {approx} 50 photoelectrons (N{sub pe}) with a laser diode providing a 1 mm spot on the MCP window. The limiting resolution achieved was {sigma}{sub Single{_}detector} {approx} 5.0 ps for N{sub pe} {approx} 180, for which they estimate the MCP-PMT contribution of {sigma}{sub MCP-PMT} {approx} 4.5 ps. The electronics contribution is estimated as {sigma}{sub Electrons} = 3.42 ps. These results suggest that an ultra-high resolution TOF detector may become a reality at future experiments one day.

  1. High-resolution x-ray diffraction microscopy of specifically labeled yeast cells

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Nelson, Johanna; Huang, Xiaojing; Steinbrener, Jan; Shapiro, David; Kirz, Janos; Marchesini, Stephano; Neiman, Aaron M.; Turner, Joshua J.; Jacobsen, Chris

    2010-04-20T23:59:59.000Z

    X-ray diffraction microscopy complements other x-ray microscopy methods by being free of lens-imposed radiation dose and resolution limits, and it allows for high-resolution imaging of biological specimens too thick to be viewed by electron microscopy. We report here the highest resolution (11-13 nm) x-ray diffraction micrograph of biological specimens, and a demonstration of molecular-specific gold labeling at different depths within cells via through-focus propagation of the reconstructed wavefield. The lectin concanavalin A conjugated to colloidal gold particles was used to label the ?-mannan sugar in the cell wall of the yeast Saccharomyces cerevisiae. Cells were plunge-frozen in liquid ethane andmore »freeze-dried, after which they were imaged whole using x-ray diffraction microscopy at 750 eV photon energy.« less

  2. High-resolution x-ray diffraction microscopy of specifically labeled yeast cells

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Nelson, Johanna [Stony Brook Univ., Stony Brook, NY (United States); Huang, Xiaojing [Stony Brook Univ., Stony Brook, NY (United States); Steinbrener, Jan [Stony Brook Univ., Stony Brook, NY (United States); Shapiro, David [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States). Advanced Light Source; Kirz, Janos [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States). Advanced Light Source; Marchesini, Stephano [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States). Advanced Light Source; Neiman, Aaron M. [Northwestern Univ., Evanston, IL (United States); Turner, Joshua J. [Stony Brook Univ., Stony Brook, NY (United States); Jacobsen, Chris [Stony Brook Univ., Stony Brook, NY (United States); Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States). Advanced Light Source; Argonne National Laboratory (ANL), Argonne, IL (United States). Advanced Photon Source

    2010-04-20T23:59:59.000Z

    X-ray diffraction microscopy complements other x-ray microscopy methods by being free of lens-imposed radiation dose and resolution limits, and it allows for high-resolution imaging of biological specimens too thick to be viewed by electron microscopy. We report here the highest resolution (11-13 nm) x-ray diffraction micrograph of biological specimens, and a demonstration of molecular-specific gold labeling at different depths within cells via through-focus propagation of the reconstructed wavefield. The lectin concanavalin A conjugated to colloidal gold particles was used to label the ?-mannan sugar in the cell wall of the yeast Saccharomyces cerevisiae. Cells were plunge-frozen in liquid ethane and freeze-dried, after which they were imaged whole using x-ray diffraction microscopy at 750 eV photon energy.

  3. Note: Design and construction of a multi-scale, high-resolution, tube-generated X-Ray computed-tomography system for three-dimensional (3D) imaging

    SciTech Connect (OSTI)

    Mertens, J. C. E.; Williams, J. J.; Chawla, Nikhilesh [Materials Science and Engineering, Security and Defense Systems Initiative, Arizona State University, 781 E. Terrace Road, ISTB4, Tempe, Arizona 85287-5604 (United States)] [Materials Science and Engineering, Security and Defense Systems Initiative, Arizona State University, 781 E. Terrace Road, ISTB4, Tempe, Arizona 85287-5604 (United States)

    2014-01-15T23:59:59.000Z

    The design and construction of a high resolution modular x-ray computed tomography (XCT) system is described. The approach for meeting a specified set of performance goals tailored toward experimental versatility is highlighted. The instrument is unique in its detector and x-ray source configuration, both of which enable elevated optimization of spatial and temporal resolution. The process for component selection is provided. The selected components are specified, the custom component design discussed, and the integration of both into a fully functional XCT instrument is outlined. The novelty of this design is a new lab-scale detector and imaging optimization through x-ray source and detector modularity.

  4. High spatial resolution upgrade of the electron cyclotron emission radiometer for the DIII-D tokamak

    SciTech Connect (OSTI)

    Truong, D. D., E-mail: dtruong@wisc.edu [Department of Engineering Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706 (United States); Austin, M. E. [Institute for Fusion Studies, University of Texas, Austin, Texas, 78712 (United States)

    2014-11-15T23:59:59.000Z

    The 40-channel DIII-D electron cyclotron emission (ECE) radiometer provides measurements of T{sub e}(r,t) at the tokamak midplane from optically thick, second harmonic X-mode emission over a frequency range of 83–130 GHz. The frequency spacing of the radiometer's channels results in a spatial resolution of ?1–3 cm, depending on local magnetic field and electron temperature. A new high resolution subsystem has been added to the DIII-D ECE radiometer to make sub-centimeter (0.6–0.8 cm) resolution T{sub e} measurements. The high resolution subsystem branches off from the regular channels’ IF bands and consists of a microwave switch to toggle between IF bands, a switched filter bank for frequency selectivity, an adjustable local oscillator and mixer for further frequency down-conversion, and a set of eight microwave filters in the 2–4 GHz range. Higher spatial resolution is achieved through the use of a narrower (200 MHz) filter bandwidth and closer spacing between the filters’ center frequencies (250 MHz). This configuration allows for full coverage of the 83–130 GHz frequency range in 2 GHz bands. Depending on the local magnetic field, this translates into a “zoomed-in” analysis of a ?2–4 cm radial region. Expected uses of these channels include mapping the spatial dependence of Alfven eigenmodes, geodesic acoustic modes, and externally applied magnetic perturbations. Initial T{sub e} measurements, which demonstrate that the desired resolution is achieved, are presented.

  5. High-speed optical sampling using a silicon-chip temporal magnifier

    E-Print Network [OSTI]

    Lipson, Michal

    of nonequilibrium electronic processes in metals," Phys. Rev. Lett. 58, 1680-1683 (1987). 3.M. Tonouchi, "Cutting-edge a silicon-chip time lens. We demonstrate the largest reported temporal magnification factor yet achieved

  6. Optimization of future high-resolution X-ray instrumentation in astrophysics

    E-Print Network [OSTI]

    Zajczyk, Anna; Dowkontt, Paul; Guo, Qingzhen; Kislat, Fabian; Krawczynski, Henric; De Geronimo, Gianluigi; Li, Shaorui; Beilicke, Matthias

    2015-01-01T23:59:59.000Z

    Cadmium Zinc Telluride and Cadmium Telluride are the detector materials of choice for the detection of X-rays in the X-ray energy band E >= 5keV with excellent spatial and spectral resolution and without cryogenic cooling. Owing to recent breakthroughs in grazing incidence mirror technology, next-generation hard X-ray telescopes will achieve angular resolution between 5 and 10 arc seconds - about an order of magnitude better than that of the NuSTAR hard X-ray telescope. As a consequence, the next generation of X-ray telescopes will require pixelated X-ray detectors with pixels on a grid with a lattice constant of <= 250um. Additional detector requirements include a low energy threshold of less than 5keV and an energy resolution of less than one keV. The science drivers for a high angular-resolution X-ray mission include studies and measurements of black hole spins, the cosmic evolution of super-massive black holes, active galactic nuclei feedback, and the behaviour of matter at very high densities. In this...

  7. Structure of W3(OH) from Very High Spectral Resolution Observations of 5 Centimeter OH Masers

    E-Print Network [OSTI]

    Vincent L. Fish; Loránt O. Sjouwerman

    2007-06-22T23:59:59.000Z

    Recent studies of methanol and ground-state OH masers at very high spectral resolution have shed new light on small-scale maser processes. The nearby source W3(OH), which contains numerous bright masers in several different transitions, provides an excellent laboratory for high spectral resolution techniques. We present a model of W3(OH) based on EVN observations of the rotationally-excited 6030 and 6035 MHz OH masers taken at 0.024 km/s spectral resolution. The 6.0 GHz masers are becoming brighter with time and show evidence for tangential proper motions. We confirm the existence of a region of magnetic field oriented toward the observer to the southeast and find another such region to the northeast in W3(OH), near the champagne flow. The 6.0 GHz masers trace the inner edge of a counterclockwise rotating torus feature. Masers at 6030 MHz are usually a factor of a few weaker than at 6035 MHz but trace the same material. Velocity gradients of nearby Zeeman components are much more closely correlated than in the ground state, likely due to the smaller spatial separation between Zeeman components. Hydroxyl maser peaks at very long baseline interferometric resolution appear to have structure on scales both smaller than that resolvable as well as on larger scales.

  8. Laser Doppler field sensor for high resolution flow velocity imaging without camera

    SciTech Connect (OSTI)

    Voigt, Andreas; Bayer, Christian; Shirai, Katsuaki; Buettner, Lars; Czarske, Juergen

    2008-09-20T23:59:59.000Z

    In this paper we present a laser sensor for highly spatially resolved flow imaging without using a camera. The sensor is an extension of the principle of laser Doppler anemometry (LDA). Instead of a parallel fringe system, diverging and converging fringes are employed. This method facilitates the determination of the tracer particle position within the measurement volume and leads to an increased spatial and velocity resolution compared to conventional LDA. Using a total number of four fringe systems the flow is resolved in two spatial dimensions and the orthogonal velocity component. Since no camera is used, the resolution of the sensor is not influenced by pixel size effects. A spatial resolution of 4 {mu}m in the x direction and 16 {mu}m in the y direction and a relative velocity resolution of 1x10{sup -3} have been demonstrated up to now. As a first application we present the velocity measurement of an injection nozzle flow. The sensor is also highly suitable for applications in nano- and microfluidics, e.g., for the measurement of flow rates.

  9. A Simple Approach for Obtaining High Resolution, High Sensitivity ¹H NMR Metabolite Spectra of Biofluids with Limited Mass Supply

    SciTech Connect (OSTI)

    Hu, Jian Zhi; Rommereim, Donald N.; Wind, Robert A.; Minard, Kevin R.; Sears, Jesse A.

    2006-11-01T23:59:59.000Z

    A simple approach is reported that yields high resolution, high sensitivity ¹H NMR spectra of biofluids with limited mass supply. This is achieved by spinning a capillary sample tube containing a biofluid at the magic angle at a frequency of about 80Hz. A 2D pulse sequence called ¹H PASS is then used to produce a high-resolution ¹H NMR spectrum that is free from magnetic susceptibility induced line broadening. With this new approach a high resolution ¹H NMR spectrum of biofluids with a volume less than 1.0 µl can be easily achieved at a magnetic field strength as low as 7.05T. Furthermore, the methodology facilitates easy sample handling, i.e., the samples can be directly collected into inexpensive and disposable capillary tubes at the site of collection and subsequently used for NMR measurements. In addition, slow magic angle spinning improves magnetic field shimming and is especially suitable for high throughput investigations. In this paper first results are shown obtained in a magnetic field of 7.05T on urine samples collected from mice using a modified commercial NMR probe.

  10. High mass resolution time of flight mass spectrometer for measuring products in heterogeneous catalysis in highly sensitive microreactors

    SciTech Connect (OSTI)

    Andersen, T.; Jensen, R.; Christensen, M. K.; Chorkendorff, I. [Department of Physics, Danish National Research Foundation's Center for Individual Nanoparticle Functionality (CINF), Technical University of Denmark, Building 312, DK-2800 Kgs. Lyngby (Denmark); Pedersen, T.; Hansen, O. [Department of Micro- and Nanotechnology, Technical University of Denmark, DTU Nanotech Building 345 East, DK-2800 Kgs. Lyngby (Denmark)

    2012-07-15T23:59:59.000Z

    We demonstrate a combined microreactor and time of flight system for testing and characterization of heterogeneous catalysts with high resolution mass spectrometry and high sensitivity. Catalyst testing is performed in silicon-based microreactors which have high sensitivity and fast thermal response. Gas analysis is performed with a time of flight mass spectrometer with a modified nude Bayard-Alpert ionization gauge as gas ionization source. The mass resolution of the time of flight mass spectrometer using the ion gauge as ionization source is estimated to m/{Delta}m > 2500. The system design is superior to conventional batch and flow reactors with accompanying product detection by quadrupole mass spectrometry or gas chromatography not only due to the high sensitivity, fast temperature response, high mass resolution, and fast acquisition time of mass spectra but it also allows wide mass range (0-5000 amu in the current configuration). As a demonstration of the system performance we present data from ammonia oxidation on a Pt thin film showing resolved spectra of OH and NH{sub 3}.

  11. High spatial resolution brain functional MRI using submillimeter balanced steady-state free precession acquisition

    SciTech Connect (OSTI)

    Wu, Pei-Hsin; Chung, Hsiao-Wen [Department of Electrical Engineering, National Taiwan University, Taipei 10617, Taiwan (China)] [Department of Electrical Engineering, National Taiwan University, Taipei 10617, Taiwan (China); Tsai, Ping-Huei [Imaging Research Center, Taipei Medical University, Taipei 11031, Taiwan and Department of Medical Imaging, Taipei Medical University Hospital, Taipei Medical University, Taipei 11031, Taiwan (China)] [Imaging Research Center, Taipei Medical University, Taipei 11031, Taiwan and Department of Medical Imaging, Taipei Medical University Hospital, Taipei Medical University, Taipei 11031, Taiwan (China); Wu, Ming-Long, E-mail: minglong.wu@csie.ncku.edu.tw [Institute of Medical Informatics, National Cheng-Kung University, Tainan 70101, Taiwan and Department of Computer Science and Information Engineering, National Cheng-Kung University, Tainan 70101, Taiwan (China)] [Institute of Medical Informatics, National Cheng-Kung University, Tainan 70101, Taiwan and Department of Computer Science and Information Engineering, National Cheng-Kung University, Tainan 70101, Taiwan (China); Chuang, Tzu-Chao [Department of Electrical Engineering, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan (China)] [Department of Electrical Engineering, National Sun Yat-Sen University, Kaohsiung 80424, Taiwan (China); Shih, Yi-Yu [Siemens Limited Healthcare Sector, Taipei 11503, Taiwan (China)] [Siemens Limited Healthcare Sector, Taipei 11503, Taiwan (China); Huang, Teng-Yi [Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan (China)] [Department of Electrical Engineering, National Taiwan University of Science and Technology, Taipei 10607, Taiwan (China)

    2013-12-15T23:59:59.000Z

    Purpose: One of the technical advantages of functional magnetic resonance imaging (fMRI) is its precise localization of changes from neuronal activities. While current practice of fMRI acquisition at voxel size around 3 × 3 × 3 mm{sup 3} achieves satisfactory results in studies of basic brain functions, higher spatial resolution is required in order to resolve finer cortical structures. This study investigated spatial resolution effects on brain fMRI experiments using balanced steady-state free precession (bSSFP) imaging with 0.37 mm{sup 3} voxel volume at 3.0 T. Methods: In fMRI experiments, full and unilateral visual field 5 Hz flashing checkerboard stimulations were given to healthy subjects. The bSSFP imaging experiments were performed at three different frequency offsets to widen the coverage, with functional activations in the primary visual cortex analyzed using the general linear model. Variations of the spatial resolution were achieved by removing outerk-space data components. Results: Results show that a reduction in voxel volume from 3.44 × 3.44 × 2 mm{sup 3} to 0.43 × 0.43 × 2 mm{sup 3} has resulted in an increase of the functional activation signals from (7.7 ± 1.7)% to (20.9 ± 2.0)% at 3.0 T, despite of the threefold SNR decreases in the original images, leading to nearly invariant functional contrast-to-noise ratios (fCNR) even at high spatial resolution. Activation signals aligning nicely with gray matter sulci at high spatial resolution would, on the other hand, have possibly been mistaken as noise at low spatial resolution. Conclusions: It is concluded that the bSSFP sequence is a plausible technique for fMRI investigations at submillimeter voxel widths without compromising fCNR. The reduction of partial volume averaging with nonactivated brain tissues to retain fCNR is uniquely suitable for high spatial resolution applications such as the resolving of columnar organization in the brain.

  12. Development of High Resolution Land Surface Parameters for the Community Land Model

    SciTech Connect (OSTI)

    Ke, Yinghai; Leung, Lai-Yung R.; Huang, Maoyi; Coleman, Andre M.; Li, Hongyi; Wigmosta, Mark S.

    2012-11-06T23:59:59.000Z

    There is a growing need for high-resolution land surface parameters as land surface models are being applied at increasingly higher spatial resolution offline as well as in regional and global models. The default land surface parameters for the most recent version of the Community Land Model (i.e. CLM 4.0) are at 0.5° or coarser resolutions, released with the Community Earth System Model (CESM). Plant Functional Types (PFTs), vegetation properties such as Leaf Area Index (LAI), Stem Area Index (SAI), and non-vegetated land covers were developed using remotely sensed datasets retrieved in late 1990’s and the beginning of this century. In this study, we developed new land surface parameters for CLM 4.0, specifically PFTs, LAI, SAI and non-vegetated land cover composition, at 0.05° resolution globally based on the most recent MODIS land cover and improved MODIS LAI products. Compared to the current CLM 4.0 parameters, the new parameters produced a decreased coverage by bare soil and trees, but an increased coverage by shrub, grass, and cropland. The new parameters result in a decrease in global seasonal LAI, with the biggest decrease in boreal forests; however, the new parameters also show a large increase in LAI in tropical forest. Differences between the new and the current parameters are mainly caused by changes in the sources of remotely sensed data and the representation of land cover in the source data. Advantages and disadvantages of each dataset were discussed in order to provide guidance on the use of the data. The new high-resolution land surface parameters have been used in a coupled land-atmosphere model (WRF-CLM) applied to the western U.S. to demonstrate their use in high-resolution modeling. A remapping method from the latitude/longitude grid of the CLM data to the WRF grids with map projection was also demonstrated. Future work will include global offline CLM simulations to examine the impacts of source data resolution and subsequent land parameter changes on simulated land surface processes.

  13. Designing Large High-Resolution Display Workspaces Alex Endert, Lauren Bradel, Jessica Zeitz, Christopher Andrews, Chris North

    E-Print Network [OSTI]

    Designing Large High-Resolution Display Workspaces Alex Endert, Lauren Bradel, Jessica Zeitz Large, high-resolution displays have enormous potential to aid in scenarios beyond their current usage seemingly small large-display design decisions can have significant impacts on users' perceptions

  14. Hierarchical object-based classification of ultra-high-resolution digital mapping camera (DMC) imagery for rangeland mapping and assessment

    E-Print Network [OSTI]

    and is in the process of changing from film to digital aerial image acquisition. Cur- rently, only broad land useHierarchical object-based classification of ultra-high-resolution digital mapping camera (DMC, MSC3JER, NMSU, Las Cruces, NM 88003-8003, USA Ultra-high-resolution digital aerial imagery has great

  15. Impact of recent lake eutrophication on microbial community changes as revealed by high resolution lipid biomarkers in Rotsee (Switzerland)

    E-Print Network [OSTI]

    Gilli, Adrian

    Impact of recent lake eutrophication on microbial community changes as revealed by high resolution t The effects of eutrophication on short term changes in the microbial community were investigated using high resolution lipid biomarker and trace metal data for sediments from the eutrophic Lake Rotsee (Swit- zerland

  16. Indoor and Outdoor in Situ High-Resolution Gamma Radiation Measurements in Urban Areas of Cyprus

    E-Print Network [OSTI]

    E. Svoukis; H. Tsertos

    2006-10-02T23:59:59.000Z

    In situ, high-resolution, gamma-ray spectrometry of a total number of 70 outdoor and 20 indoor representative measurements were performed in preselected, common locations of the main urban areas of Cyprus. Specific activities and gamma absorbed dose rates in air due to the naturally occurring radionuclides of Th-232 and U-238 series, and K-40 are determined and discussed. Effective dose rate to the Cyprus population due to terrestrial gamma radiation is derived directly from this work. The results obtained outdoors match very well with those derived previously by high-resolution gamma spectrometry of soil samples, which were collected from the main island bedrock surface. This implies that the construction and building materials in urban areas do not affect the external gamma dose rate; thus they are mostly of local origin. Finally, the indoor/outdoor gamma dose ratio was found to be 1.4 +- 0.5.

  17. Indoor and Outdoor in Situ High-Resolution Gamma Radiation Measurements in Urban Areas of Cyprus

    E-Print Network [OSTI]

    Svoukis, E

    2006-01-01T23:59:59.000Z

    In situ, high-resolution, gamma-ray spectrometry of a total number of 70 outdoor and 20 indoor representative measurements were performed in preselected, common locations of the main urban areas of Cyprus. Specific activities and gamma absorbed dose rates in air due to the naturally occurring radionuclides of Th-232 and U-238 series, and K-40 are determined and discussed. Effective dose rate to the Cyprus population due to terrestrial gamma radiation is derived directly from this work. The results obtained outdoors match very well with those derived previously by high-resolution gamma spectrometry of soil samples, which were collected from the main island bedrock surface. This implies that the construction and building materials in urban areas do not affect the external gamma dose rate; thus they are mostly of local origin. Finally, the indoor/outdoor gamma dose ratio was found to be 1.4 +- 0.5.

  18. High resolution seismic survey (of the) Rawlins, Wyoming underground coal gasification area. Final report

    SciTech Connect (OSTI)

    Youngberg, A.D.; Berkman, E.; Orange, A.S.

    1983-01-01T23:59:59.000Z

    In October 1982, a high resolution seismic survey was conducted at the Gulf Research and Development Company's underground coal gasification test site near Rawlins, Wyoming. The objectives of the survey were to utilize high resolution seismic technology to locate and characterize two underground coal burn zones. Seismic data acquisition and processing parameters were specifically designed to emphasize reflections at the shallow depths of interest. A three-dimensional grid of data was obtained over the Rawlins burn zones. Processing included time varying filters, trace composition, and two-dimensional areal stacking of the data in order to identify burn zone anomalies. An anomaly was discernable resulting from the rubble-collapse cavity associated with the burn zone which was studied in detail at the Rawlins 1 and 2 test sites. 21 refs., 20 figs.

  19. Superconducting gamma and fast-neutron spectrometers with high energy resolution

    DOE Patents [OSTI]

    Friedrich, Stephan (San Jose, CA); , Niedermayr, Thomas R. (Oakland, CA); Labov, Simon E. (Berkeley, CA)

    2008-11-04T23:59:59.000Z

    Superconducting Gamma-ray and fast-neutron spectrometers with very high energy resolution operated at very low temperatures are provided. The sensor consists of a bulk absorber and a superconducting thermometer weakly coupled to a cold reservoir, and determines the energy of the incident particle from the rise in temperature upon absorption. A superconducting film operated at the transition between its superconducting and its normal state is used as the thermometer, and sensor operation at reservoir temperatures around 0.1 K reduces thermal fluctuations and thus enables very high energy resolution. Depending on the choice of absorber material, the spectrometer can be configured either as a Gamma-spectrometer or as a fast-neutron spectrometer.

  20. Gas-Phase Molecular Dynamics: High Resolution Spectroscopy and Collision Dynamics of Transient Species

    SciTech Connect (OSTI)

    Hall, G.E.

    2011-05-31T23:59:59.000Z

    This research is carried out as part of the Gas-Phase Molecular Dynamics program in the Chemistry Department at Brookhaven National Laboratory. Chemical intermediates in the elementary gas-phase reactions involved in combustion chemistry are investigated by high resolution spectroscopic tools. Production, reaction, and energy transfer processes are investigated by transient, double resonance, polarization and saturation spectroscopies, with an emphasis on technique development and connection with theory, as well as specific molecular properties.

  1. High time resolution observations of the solar wind and backstreaming ions in the earth's foreshock region

    SciTech Connect (OSTI)

    Formisano, V.; Orsini, S.; Bonifazi, C.; Egidi, A.; Moreno, G.

    1980-05-01T23:59:59.000Z

    The interaction of the solar wind with ions backstreaming from the earth's bow shock is studied at high time resolution. It turns out that the bulk velocity of the solar wind oscillates, both in magnitude and direction, with typical periods of approx.1 minute in presence of the 'diffuse' ion population. Oscillations of comparable periods are also observed in the angular distribution and energy spectrum of the diffuse ions.

  2. High-Resolution Genomic Profiles of Breast Cancer Cell Lines Assessed by Tiling BAC Array

    E-Print Network [OSTI]

    Lunds Universitet,

    number changes in 10 breast cancer cell lines (BT474, MCF7, HCC1937, SK-BR-3, L56Br-C1, ZR-75-1, JIMT1High-Resolution Genomic Profiles of Breast Cancer Cell Lines Assessed by Tiling BAC Array, MDA-MB-231, MDA-MB-361, and HCC2218) and one cell line derived from fibrocystic disease of the breast

  3. A high-resolution, four-band SAR testbed with real-time image formation

    SciTech Connect (OSTI)

    Walker, B.; Sander, G.; Thompson, M.; Burns, B.; Fellerhoff, R.; Dubbert, D.

    1996-03-01T23:59:59.000Z

    This paper describes the Twin-Otter SAR Testbed developed at Sandia National Laboratories. This SAR is a flexible, adaptable testbed capable of operation on four frequency bands: Ka, Ku, X, and VHF/UHF bands. The SAR features real-time image formation at fine resolution in spotlight and stripmap modes. High-quality images are formed in real time using the overlapped subaperture (OSA) image-formation and phase gradient autofocus (PGA) algorithms.

  4. High Resolution Studies of the Origins of Polyatomic Ions in Inductively Coupled Plasma-Mass Spectrometry

    SciTech Connect (OSTI)

    Jill Wisnewski Ferguson

    2006-08-09T23:59:59.000Z

    The inductively coupled plasma (ICP) is an atmospheric pressure ionization source. Traditionally, the plasma is sampled via a sampler cone. A supersonic jet develops behind the sampler, and this region is pumped down to a pressure of approximately one Torr. A skimmer cone is located inside this zone of silence to transmit ions into the mass spectrometer. The position of the sampler and skimmer cones relative to the initial radiation and normal analytical zones of the plasma is key to optimizing the useful analytical signal [1]. The ICP both atomizes and ionizes the sample. Polyatomic ions form through ion-molecule interactions either in the ICP or during ion extraction [l]. Common polyatomic ions that inhibit analysis include metal oxides (MO{sup +}), adducts with argon, the gas most commonly used to make up the plasma, and hydride species. While high resolution devices can separate many analytes from common interferences, this is done at great cost in ion transmission efficiency--a loss of 99% when using high versus low resolution on the same instrument [2]. Simple quadrupole devices, which make up the bulk of ICP-MS instruments in existence, do not present this option. Therefore, if the source of polyatomic interferences can be determined and then manipulated, this could potentially improve the figures of merit on all ICP-MS devices, not just the high resolution devices often utilized to study polyatomic interferences.

  5. Application of Spatially Resolved High Resolution Crystal Spectrometry to ICF Plasmas

    SciTech Connect (OSTI)

    Kenneth W. Hill, et. al.

    2012-09-15T23:59:59.000Z

    High resolution (?/?#3;? ~ 10 000) 1D imaging x-ray spectroscopy using a spherically bent crystal and a 2D hybrid pixel array detector is used world wide for Doppler measurements of ion-temperature and plasma flow-velocity profiles in magnetic confinement fusion plasmas. Meter sized plasmas are diagnosed with cm spatial resolution and 10 ms time resolution. This concept can also be used as a diagnostic of small sources, such as inertial confinement fusion plasmas and targets on x-ray light source beam lines, with spatial resolution of micrometers, as demonstrated by laboratory experiments using a 250-?m 55 Fe source, and by ray-tracing calculations. Throughput calculations agree with measurements, and predict detector counts in the range 10-8 -10-6 times source x-rays, depending on crystal reflectivity and spectrometer geometry. Results of the lab demonstrations, application of the technique to the National Ignition Facility (NIF), and predictions of performance on NIF will be presented.

  6. Application of spatially resolved high resolution crystal spectrometry to inertial confinement fusion plasmas

    SciTech Connect (OSTI)

    Hill, K. W.; Bitter, M.; Delgado-Aparacio, L.; Pablant, N. A. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Beiersdorfer, P.; Schneider, M.; Widmann, K. [Physics Division, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Sanchez del Rio, M. [European Synchrotron Radiation Facility, BP 220, 38043-Grenoble Cedex (France); Zhang, L. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031 (China)

    2012-10-15T23:59:59.000Z

    High resolution ({lambda}/{Delta}{lambda}{approx} 10 000) 1D imaging x-ray spectroscopy using a spherically bent crystal and a 2D hybrid pixel array detector is used world wide for Doppler measurements of ion-temperature and plasma flow-velocity profiles in magnetic confinement fusion plasmas. Meter sized plasmas are diagnosed with cm spatial resolution and 10 ms time resolution. This concept can also be used as a diagnostic of small sources, such as inertial confinement fusion plasmas and targets on x-ray light source beam lines, with spatial resolution of micrometers, as demonstrated by laboratory experiments using a 250-{mu}m {sup 55}Fe source, and by ray-tracing calculations. Throughput calculations agree with measurements, and predict detector counts in the range 10{sup -8}-10{sup -6} times source x-rays, depending on crystal reflectivity and spectrometer geometry. Results of the lab demonstrations, application of the technique to the National Ignition Facility (NIF), and predictions of performance on NIF will be presented.

  7. A design for a high resolution very-low-Q time-of flight diffractometer.

    SciTech Connect (OSTI)

    Hjelm, R. P.

    1998-09-29T23:59:59.000Z

    The design of a high resolution view low-Q time of flight diffractometer was motivated by the anticipated need to perform small-angle neutron scattering measurements at far lower momentum transfer and higher precision than currently available at either pulsed or steady state sources. In addition, it was recognized that flexibility in the configuration of the instrument and ease in which data is acquired are important. The design offers two configurations, a high intensity/very low Q geometry employing a focusing mirror and a medium to high Q-precision/low Q configuration using standard pinhole collimation geometry. The quality of the mirror optics is very important to the performance of the high intensity/very low Q configuration. We believe that the necessary technology exists to fabricate the high quality mirror optics required for the instrument.

  8. Measurement of low radioactivity background in a high voltage cable by high resolution inductively coupled plasma mass spectrometry

    SciTech Connect (OSTI)

    Vacri, M. L. di; Nisi, S.; Balata, M. [Gran Sasso National Laboratory, Chemistry Service, SS 17bis km 18.910, 67100 Assergi (Aq) (Italy)] [Gran Sasso National Laboratory, Chemistry Service, SS 17bis km 18.910, 67100 Assergi (Aq) (Italy)

    2013-08-08T23:59:59.000Z

    The measurement of naturally occurring low level radioactivity background in a high voltage (HV) cable by high resolution inductively coupled plasma mass spectrometry (HR ICP MS) is presented in this work. The measurements were performed at the Chemistry Service of the Gran Sasso National Laboratory. The contributions to the radioactive background coming from the different components of the heterogeneous material were separated. Based on the mass fraction of the cable, the whole contamination was calculated. The HR ICP MS results were cross-checked by gamma ray spectroscopy analysis that was performed at the low background facility STELLA (Sub Terranean Low Level Assay) of the LNGS underground lab using HPGe detectors.

  9. Ultra-high-resolution alpha spectrometry for nuclear forensics and safeguards applications

    SciTech Connect (OSTI)

    Bacrania, Minesh K [Los Alamos National Laboratory; Croce, Mark [Los Alamos National Laboratory; Bond, Evelyn [Los Alamos National Laboratory; Dry, Donald [Los Alamos National Laboratory; Moody, W. Allen [Los Alamos National Laboratory; Lamont, Stephen [Los Alamos National Laboratory; Rabin, Michael [Los Alamos National Laboratory; Rim, Jung [Los Alamos National Laboratory; Smith, Audrey [Los Alamos National Laboratory; Beall, James [NIST-BOULDER; Bennett, Douglas [NIST-BOULDER; Kotsubo, Vincent [NIST-BOULDER; Horansky, Robert [NIST-BOULDER; Hilton, Gene [NIST-BOULDER; Schmidt, Daniel [NIST-BOULDER; Ullom, Joel [NIST-BOULDER; Cantor, Robin [STAR CRYOELECTRONICS

    2010-01-01T23:59:59.000Z

    We will present our work on the development of ultra-high-resolution detectors for alpha particle spectrometry. These detectors, based on superconducting transition-edge sensors, offer energy resolution that is five to ten times better than conventional silicon detectors. Using these microcalorimeter detectors, the isotopic composition of mixed-actinide samples can be determined rapidly without the need for actinide separation chemistry to isolate each element, or mass spectrometry to separate isotopic signatures that can not be resolved using traditional alpha spectrometry (e.g. Pu-239/Pu-240, or Pu-238/Am-241). This paper will cover the detector and measurement system, actinide source preparation, and the quantitative isotopic analysis of a number of forensics- and safeguards-relevant radioactive sources.

  10. New developments in high resolution borehole seismology and their applications to reservoir development and management

    SciTech Connect (OSTI)

    Paulsson, B.N.P. [Chevron Petroleum Technology Company, La Habra, CA (United States)

    1997-08-01T23:59:59.000Z

    Single-well seismology, Reverse Vertical Seismic Profiles (VSP`s) and Crosswell seismology are three new seismic techniques that we jointly refer to as borehole seismology. Borehole seismic techniques are of great interest because they can obtain much higher resolution images of oil and gas reservoirs than what is obtainable with currently used seismic techniques. The quality of oil and gas reservoir management decisions depend on the knowledge of both the large and the fine scale features in the reservoirs. Borehole seismology is capable of mapping reservoirs with an order of magnitude improvement in resolution compared with currently used technology. In borehole seismology we use a high frequency seismic source in an oil or gas well and record the signal in the same well, in other wells, or on the surface of the earth.

  11. Keck High-Resolution Spectroscopy of Outflows in Infrared Luminous Galaxies

    E-Print Network [OSTI]

    David S. Rupke; Sylvain Veilleux

    2005-09-05T23:59:59.000Z

    Several recent studies have determined that large quantities of neutral gas are outflowing from the nuclei of almost all infrared-luminous galaxies. These measurements show that winds in infrared-luminous galaxies play a significant role in the evolution of galaxies and the intergalactic medium at redshifts z > 1, when infrared-luminous galaxies dominated the star formation rate of the universe. These conclusions rely on moderate resolution spectra (FWHM > 65 km/s) of the NaI D absorption line and the assumption that there are no unresolved, saturated velocity components. For the first time, we present high resolution spectra (FWHM = 13 km/s) of massive, infrared-luminous galaxies. The five galaxies in our sample are known to host outflows on the basis of previous observations. With the present observations, all NaI D velocity components are resolved with tau(NaI D1 5896 A) luminous galaxies have been measured correctly by previous studies.

  12. The High-Resolution Lightweight Telescope for the EUV (HiLiTE)

    SciTech Connect (OSTI)

    Martinez-Galarce, D S; Boerner, P; Soufli, R; De Pontieu, B; Katz, N; Title, A; Gullikson, E M; Robinson, J C; Baker, S L

    2008-06-02T23:59:59.000Z

    The High-resolution Lightweight Telescope for the EUV (HiLiTE) is a Cassegrain telescope that will be made entirely of Silicon Carbide (SiC), optical substrates and metering structure alike. Using multilayer coatings, this instrument will be tuned to operate at the 465 {angstrom} Ne VII emission line, formed in solar transition region plasma at {approx}500,000 K. HiLiTE will have an aperture of 30 cm, angular resolution of {approx}0.2 arc seconds and operate at a cadence of {approx}5 seconds or less, having a mass that is about 1/4 that of one of the 20 cm aperture telescopes on the Atmospheric Imaging Assembly (AIA) instrument aboard NASA's Solar Dynamics Observatory (SDO). This new instrument technology thus serves as a path finder to a post-AIA, Explorer-class missions.

  13. Short range, ultra-wideband radar with high resolution swept range gate

    DOE Patents [OSTI]

    McEwan, Thomas E. (Livermore, CA)

    1998-05-26T23:59:59.000Z

    A radar range finder and hidden object locator is based on ultra-wide band radar with a high resolution swept range gate. The device generates an equivalent time amplitude scan with a typical range of 4 inches to 20 feet, and an analog range resolution as limited by a jitter of on the order of 0.01 inches. A differential sampling receiver is employed to effectively eliminate ringing and other aberrations induced in the receiver by the near proximity of the transmit antenna, so a background subtraction is not needed, simplifying the circuitry while improving performance. Uses of the invention include a replacement of ultrasound devices for fluid level sensing, automotive radar, such as cruise control and parking assistance, hidden object location, such as stud and rebar finding. Also, this technology can be used when positioned over a highway lane to collect vehicle count and speed data for traffic control.

  14. Short range, ultra-wideband radar with high resolution swept range gate

    DOE Patents [OSTI]

    McEwan, T.E.

    1998-05-26T23:59:59.000Z

    A radar range finder and hidden object locator is based on ultra-wide band radar with a high resolution swept range gate. The device generates an equivalent time amplitude scan with a typical range of 4 inches to 20 feet, and an analog range resolution as limited by a jitter of on the order of 0.01 inches. A differential sampling receiver is employed to effectively eliminate ringing and other aberrations induced in the receiver by the near proximity of the transmit antenna, so a background subtraction is not needed, simplifying the circuitry while improving performance. Uses of the invention include a replacement of ultrasound devices for fluid level sensing, automotive radar, such as cruise control and parking assistance, hidden object location, such as stud and rebar finding. Also, this technology can be used when positioned over a highway lane to collect vehicle count and speed data for traffic control. 14 figs.

  15. High Resolution X-Ray Scattering at Sector 3, Advanced Photon...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    about 1 meV resolution; momentum resolved inelastic x-ray scattering with about 1 meV resolution (HERIX); Synchrotron Mossbauer spectroscopy with about 10 neV resolution (SMS)....

  16. High resolution detection and excitation of resonant magnetic perturbations in a wall-stabilized tokamak

    SciTech Connect (OSTI)

    Maurer, David A. [Physics Department, Auburn University, Auburn, Alabama 36849 (United States); Shiraki, Daisuke; Levesque, Jeffrey P.; Bialek, James; Angelini, Sarah; Byrne, Patrick; DeBono, Bryan; Hughes, Paul; Mauel, Michael E.; Navratil, Gerald A.; Peng Qian; Rhodes, Dov; Rath, Nickolaus; Stoafer, Christopher [Department of Applied Physics and Applied Mathematics, Columbia University, New York, New York 10027 (United States)

    2012-05-15T23:59:59.000Z

    We report high-resolution detection of the 3D plasma magnetic response of wall-stabilized tokamak discharges in the High Beta Tokamak-Extended Pulse [T. H. Ivers et al., Phys. Plasmas 3, 1926 (1996)] device. A new adjustable conducting wall has been installed on HBT-EP made up of 20 independent, movable, wall segments instrumented with three distinct sets of 40 modular coils that can be independently driven to generate a wide variety of magnetic perturbations. High-resolution detection of the plasma response is made with 216 poloidal and radial magnetic sensors that have been located and calibrated with high-accuracy. Static and dynamic plasma responses to resonant and non-resonant magnetic perturbations are observed through measurement of the step-response following a rapid change in the toroidal phase of the applied perturbations. Biorthogonal decomposition of the full set of magnetic sensors clearly defines the structures of naturally occurring external kinks as being composed of independent m/n = 3/1 and 6/2 modes. Resonant magnetic perturbations were applied to discharges with pre-existing, saturated m/n = 3/1 external kink mode activity. This m/n = 3/1 kink mode was observed to lock to the applied perturbation field. During this kink mode locked period, the plasma resonant response is characterized by a linear, a saturated, and a disruptive plasma regime dependent on the magnitude of the applied field and value of the edge safety factor and plasma rotation.

  17. c 2013 by Jacob Thomas Stewart. All rights reserved. HIGH-RESOLUTION INFRARED SPECTROSCOPY OF LARGE MOLECULES AND

    E-Print Network [OSTI]

    McCall, Benjamin J.

    OF LARGE MOLECULES AND WATER CLUSTERS USING QUANTUM CASCADE LASERS BY JACOB THOMAS STEWART DISSERTATION-resolution spectroscopic studies of large molecules and water clusters which have been obtained using a quantum cascade cooling of polycyclic aromatic hydrocarbons (PAHs), including high-resolution spectroscopy of pyrene (C16H

  18. Rapid detection and identification of non-tuberculous mycobacterial pathogens in fish1 using high resolution melting analysis (HRMA)2

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    resolution melting analysis (HRMA)2 3 4 Thu Nguyet Phung 1,2 , Domenico Caruso 2 , Sylvain Godreuil 3 19 Running title: identification of fish mycobateria by HRMA20 ird-00940286,version1-31Jan2014 Author diagnostic test exists, we tested the potential of27 high resolution melting analysis (HRMA) to rapidly

  19. THE USE OF THE HIGH RESOLUTION VISIBLE IN SAFNWC/MSG Marcel Derrien, Herv Le Glau, Marie-Paule Raoul

    E-Print Network [OSTI]

    Boyer, Edmond

    in this paper is an output of this task. HRV IMAGERY CHARACTERISTICS SEVIRI has one high resolution (HRes) broadband solar channel (0.3-1.1 m) and 11 lower resolution (LRes) channels; 3 narrowband solar channels (0 scheme of HRV data.

  20. Time series of high resolution photospheric spectra in a quiet region of the Sun. II. Analysis of the variation of physical quantities of granular structures

    E-Print Network [OSTI]

    Puschmann, K G; Vazquez, M; Bonet, J A; Hanslmeier, A; 10.1051/0004-6361:20047193

    2012-01-01T23:59:59.000Z

    From the inversion of a time series of high resolution slit spectrograms obtained from the quiet sun, the spatial and temporal distribution of the thermodynamical quantities and the vertical flow velocity is derived as a function of logarithmic optical depth and geometrical height. Spatial coherence and phase shift analyzes between temperature and vertical velocity depict the height variation of these physical quantities for structures of different size. An average granular cell model is presented, showing the granule-intergranular lane stratification of temperature, vertical velocity, gas pressure and density as a function of logarithmic optical depth and geometrical height. Studies of a specific small and a specific large granular cell complement these results. A strong decay of the temperature fluctuations with increasing height together with a less efficient penetration of smaller cells is revealed. The T -T coherence at all granular scales is broken already at log tau =-1 or z~170 km. At the layers beyon...

  1. SMA Observations of Class 0 Protostars: A High-Angular Resolution Survey of Protostellar Binary Systems

    E-Print Network [OSTI]

    Chen, Xuepeng; Zhang, Qizhou; Bourke, Tyler L; Launhardt, Ralf; Jorgensen, Jes K; Lee, Chin-Fee; Foster, Jonathan B; Dunham, Michael M; Pineda, Jaime E; Henning, Thomas

    2013-01-01T23:59:59.000Z

    We present high angular resolution 1.3 mm and 850 um dust continuum data obtained with the Submillimeter Array toward 33 Class 0 protostars in nearby clouds (distance < 500 pc), which represents so far the largest survey toward protostellar binary/multiple systems. The median angular resolution in the survey is 2.5 arcsec, while the median linear resolution is approximately 600 AU. Compact dust continuum emission is observed from all sources in the sample. Twenty-one sources in the sample show signatures of binarity/multiplicity, with separations ranging from 50 to 5000 AU. The numbers of singles, binaries, triples, and quadruples in the sample are 12, 14, 5, and 2, respectively. The derived multiplicity frequency (MF) and companion star fraction (CSF) for Class 0 protostars are 0.64+/-0.08 and 0.91+/-0.05, respectively, with no correction for completeness. The derived MF and CSF in this survey are approximately two times higher than the values found in the binary surveys toward Class I YSOs, and approxima...

  2. High resolution x-ray lensless imaging by differential holographic encoding

    SciTech Connect (OSTI)

    Zhu, D.; Guizar-Sicairos, M.; Wu, B.; Scherz, A.; Acremann, Y.; Tylisczcak, T.; Fischer, P.; Friedenberger, N.; Ollefs, K.; Farle, M.; Fienup, J. R.; Stohr, J.

    2009-11-02T23:59:59.000Z

    X-ray free electron lasers (X-FEL{sub s}) will soon offer femtosecond pulses of laterally coherent x-rays with sufficient intensity to record single-shot coherent scattering patterns for nanoscale imaging. Pulse trains created by splitand-delay techniques even open the door for cinematography on unprecedented nanometer length and femtosecond time scales. A key to real space ultrafast motion pictures is fast and reliable inversion of the recorded reciprocal space scattering patterns. Here we for the first time demonstrate in the x-ray regime the power of a novel technique for lensless high resolution imaging, previously suggested by Guizar-Sicairos and Fienup termed holography with extended reference by autocorrelation linear differential operation, HERALD0. We have achieved superior resolution over conventional x-ray Fourier transform holography (FTH) without sacrifices in SNR or significant increase in algorithmic complexity. By combining images obtained from individual sharp features on an extended reference, we further show that the resolution can be even extended beyond the reference fabrication limits. Direct comparison to iterative phase retrieval image reconstruction and images recorded with stateof- the-art zone plate microscopes is presented. Our results demonstrate the power of HERALDO as a favorable candidate for robust inversion of single-shot coherent scattering patterns.

  3. Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography

    SciTech Connect (OSTI)

    Brun, E., E-mail: emmanuel.brun@esrf.fr [European Synchrotron Radiation Facility (ESRF), Grenoble 380000, France and Department of Physics, Ludwig-Maximilians University, Garching 85748 (Germany); Grandl, S.; Sztrókay-Gaul, A.; Gasilov, S. [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Barbone, G. [Department of Physics, Harvard University, Cambridge, Massachusetts 02138 (United States); Mittone, A.; Coan, P. [Department of Physics, Ludwig-Maximilians University, Garching 85748, Germany and Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich, 81377 Munich (Germany); Bravin, A. [European Synchrotron Radiation Facility (ESRF), Grenoble 380000 (France)

    2014-11-01T23:59:59.000Z

    Purpose: Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. Methods: The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure’s possible applications. Results: A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. Conclusions: The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

  4. WAVELETS WITH RIDGES: A HIGH-RESOLUTION REPRESENTATION OF CATACLYSMIC VARIABLE TIME SERIES

    SciTech Connect (OSTI)

    Blackman, Claire, E-mail: claire.blackman@rhul.ac.u [Department of Economics, Royal Holloway, University of London, Egham, Surrey TW20 0EX (United Kingdom)

    2010-11-15T23:59:59.000Z

    Quasi-periodic oscillations (QPO) and dwarf nova oscillations (DNOs) occur in dwarf novae and nova-like variables during outburst and occasionally during quiescence, and have analogs in high-mass X-ray binaries and black-hole candidates. The frequent low coherence of quasi-period oscillations and DNOs can make detection with standard time-series tools such as periodograms problematic. This paper develops tools to analyze quasi-periodic brightness oscillations. We review the use of time-frequency representations (TFRs) in the astronomical literature, and show that representations such as the Choi-Williams distribution and Zhao-Atlas-Marks representation, which are best suited to high signal-to-noise data, cannot be assumed a priori to be the best techniques for our data, which have a much higher noise level and lower coherence. This leads us to a detailed analysis of the time-frequency resolution and statistical properties of six TFRs. We conclude that the wavelet scalogram, with the addition of wavelet ridges and maxima points, is the most effective TFR for analyzing quasi-periodicities in low signal-to-noise data, as it has high time-frequency resolution, and is a minimum variance estimator. We use the wavelet ridges method to re-analyze archival data from VW Hyi, and find 62 new QPOs and 7 new long-period DNOs. Relative to previous analyses, our method substantially improves the detection rate for QPOs.

  5. Time series of high resolution spectra of SN 2014J observed with the TIGRE telescope

    E-Print Network [OSTI]

    Jack, D; Schroder, K -P; Schmitt, J H M M; Hempelmann, A; Gonzalez-Perez, J N; Trinidad, M A; Rauw, G; Sixto, J M Cabrera

    2015-01-01T23:59:59.000Z

    We present a time series of high resolution spectra of the Type Ia supernova 2014J, which exploded in the nearby galaxy M82. The spectra were obtained with the HEROS echelle spectrograph installed at the 1.2 m TIGRE telescope. We present a series of 33 spectra with a resolution of R = 20, 000, which covers the important bright phases in the evolution of SN 2014J during the period from January 24 to April 1 of 2014. The spectral evolution of SN 2014J is derived empirically. The expansion velocities of the Si II P-Cygni features were measured and show the expected decreasing behaviour, beginning with a high velocity of 14,000 km/s on January 24. The Ca II infrared triplet feature shows a high velocity component with expansion velocities of > 20, 000 km/s during the early evolution apart from the normal component showing similar velocities as Si II. Further broad P-Cygni profiles are exhibited by the principal lines of Ca II, Mg II and Fe II. The TIGRE SN 2014J spectra also resolve several very sharp Na I D doub...

  6. High-Resolution Infrared and Electron-Diffraction Studies of Trimethylenecyclopropane ([3]-Radialene)

    SciTech Connect (OSTI)

    Wright, Corey R.; Holmes, Joshua; Nibler, Joseph W.; Hedberg, Kenneth; White, James D.; Hedberg, Lise; Weber, Alfons; Blake, Thomas A.

    2013-05-16T23:59:59.000Z

    Combined high-resolution spectroscopic, electron-diffraction, and quantum theoretical methods are particularly advantageous for small molecules of high symmetry and can yield accurate structures that reveal subtle effects of electron delocalization on molecular bonds. The smallest of the radialene compounds, trimethylenecyclopropane, [3]-radialene, has been synthesized and examined in the gas phase by these methods. The first high-resolution infrared spectra have been obtained for this molecule of D3h symmetry, leading to an accurate B0 rotational constant value of 0.1378629(8) cm-1, within 0.5% of the value obtained from electronic structure calculations (density functional theory (DFT) B3LYP/cc-pVTZ). This result is employed in an analysis of electron-diffraction data to obtain the rz bond lengths (in Å): C-H = 1.072 (17), C-C = 1.437 (4), and C=C = 1.330 (4). The analysis does not lead to an accurate value of the HCH angle; however, from comparisons of theoretical and experimental angles for similar compounds, the theoretical prediction of 117.5? is believed to be reliable to within 2?. The effect of electron delocalization in radialene is to reduce the single C-C bond length by 0.07 Å compared to that in cyclopropane.

  7. Scientific system for high-resolution measurement of the circumsolar radiation

    SciTech Connect (OSTI)

    Schrott, Simeon, E-mail: thomas.schmidt@ise.fraunhofer.de; Schmidt, Thomas, E-mail: thomas.schmidt@ise.fraunhofer.de; Hornung, Thorsten, E-mail: thomas.schmidt@ise.fraunhofer.de; Nitz, Peter, E-mail: thomas.schmidt@ise.fraunhofer.de [Fraunhofer Institute for Solar Energy Systems ISE, Freiburg (Germany)

    2014-09-26T23:59:59.000Z

    We developed a camera based system for measurements of the circumsolar radiation with a high angular resolution of 0.1 mrad. Subsequent measurements may be taken at intervals as short as 15 s. In this publication we describe the optical system in detail and discuss some aspects of the measurement method. First results from two days of measurement at Freiburg i. Br., Germany, are presented and compared to data from literature. The good results encourage us to perform longer measurement campaigns in future to better understand the influence of circumsolar radiation on the power yield of concentrating photovoltaic systems.

  8. Techniques for measuring atmospheric aerosols at the High Resolution Fly's Eye experiment

    E-Print Network [OSTI]

    The HiRes Collaboration

    2005-12-15T23:59:59.000Z

    We describe several techniques developed by the High Resolution Fly's Eye experiment for measuring aerosol vertical optical depth, aerosol horizontal attenuation length, and aerosol phase function. The techniques are based on measurements of side-scattered light generated by a steerable ultraviolet laser and collected by an optical detector designed to measure fluorescence light from cosmic-ray air showers. We also present a technique to cross-check the aerosol optical depth measurement using air showers observed in stereo. These methods can be used by future air fluorescence experiments.

  9. High-resolution imaging and target designation through clouds or smoke

    DOE Patents [OSTI]

    Perry, Michael D. (Downy, CA)

    2003-01-01T23:59:59.000Z

    A method and system of combining gated intensifiers and advances in solid-state, short-pulse laser technology, compact systems capable of producing high resolution (i.e., approximately less than 20 centimeters) optical images through a scattering medium such as dense clouds, fog, smoke, etc. may be achieved from air or ground based platforms. Laser target designation through a scattering medium is also enabled by utilizing a short pulse illumination laser and a relatively minor change to the detectors on laser guided munitions.

  10. Magnetic lens apparatus for a low-voltage high-resolution electron microscope

    DOE Patents [OSTI]

    Crewe, Albert V. (Palos Park, IL)

    1996-01-01T23:59:59.000Z

    A lens apparatus in which a beam of charged particles of low accelerating voltage is brought to a focus by a magnetic field, the lens being situated behind the target position. The lens comprises an electrically-conducting coil arranged around the axis of the beam and a magnetic pole piece extending along the axis of the beam at least within the space surrounded by the coil. The lens apparatus comprises the sole focusing lens for high-resolution imaging in a low-voltage scanning electron microscope.

  11. High-resolution methods for preserving the sum of mass fractions: improved ?-scheme and an alternative

    SciTech Connect (OSTI)

    Syamlal, Madhava; Benyahia, Sofiane

    2013-11-20T23:59:59.000Z

    When high resolution convection schemes are used for discretizing chemical species mass balance equations, the mass fractions are not guaranteed to add to one. We show that a proposed remedy called ?-scheme (Darwish and Moukalled, Comput.Methods Appl.Mech. Engrg. 192 (2003): 1711) will degrade to a diffusive first-order scheme when a chemical species vanishes from the mixture, for example, because of chemical reactions. We propose an improvement to the ?-scheme to overcome this problem. Furthermore, a computationally efficient alternative scheme is proposed and evaluated with several examples, to quantify the improvements in the accuracy and the computational time.

  12. High-resolution inverse Raman and resonant-wave-mixing spectroscopy

    SciTech Connect (OSTI)

    Rahn, L.A. [Sandia National Laboratories, Livermore, CA (United States)

    1993-12-01T23:59:59.000Z

    These research activities consist of high-resolution inverse Raman spectroscopy (IRS) and resonant wave-mixing spectroscopy to support the development of nonlinear-optical techniques for temperature and concentration measurements in combustion research. Objectives of this work include development of spectral models of important molecular species needed to perform coherent anti-Stokes Raman spectroscopy (CARS) measurements and the investigation of new nonlinear-optical processes as potential diagnostic techniques. Some of the techniques being investigated include frequency-degenerate and nearly frequency-degenerate resonant four-wave-mixing (DFWM and NDFWM), and resonant multi-wave mixing (RMWM).

  13. Large area, high spatial resolution tracker for new generation of high luminosity experiments in Hall A at Jefferson Lab

    SciTech Connect (OSTI)

    Bellini, V; Castelluccio, D; Colilli, S; Cisbani, E; De Leo, R; Fratoni, R; Frullani, S; Garibaldi, F; Guiliani, F; Guisa, A; Gricia, M; Lucentini, M; Meddi, F; Minutoli, S; Musico, P; Noto, F; De Oliveira, R; Santavenere, F; Sutera, M C

    2011-06-01T23:59:59.000Z

    In 2014 the CEBAF electron accelerator at Jefferson Lab (JLab) will deliver a longitudinally polarized (up to 85%), high intensity (up to 100 ?A) beam with maximum energy of 12 GeV, twice the present value. To exploit the new opportunities that the energy upgrade will offer, a new spectrometer (Super BigBite - SBS) is under development, featuring very forward angle, large acceptance and ability to operate in high luminosity environment. The tracking system of SBS will consist of large area (40×150 cm2 and 50×200 cm2), high spatial resolution (better than 100 ?m) chambers based on the GEM technology and 2 small (10×20 cm) Silicon Strip Detector planes. The design of the GEM chambers and its sub-components such as the readout electronics is resented here.

  14. A new variable-resolution associative memory for high energy physics

    SciTech Connect (OSTI)

    Annovi, A. [INFN Frascati (Italy); Amerio, S. [INFN Padova (Italy); Beretta, M. [INFN Frascati (Italy); Bossini, E.; Crescioli, F.; Dell'Orso, M.; Giannetti, P. [INFN Pisa (Italy); Hoff, J.; Liu, T. [Fermilab (United States); Magalotti, D. [INFN Perugia (Italy); Piendibene, M.; Sacco, I. [INFN Pisa (Italy); Schoening, A.; Soltveit, H. K. [Univ. of Heidelberg (Germany); Stabile, A. [INFN Milano (Italy); Tripiccione, R. [INFN Ferrara (Italy); Liberali, V. [INFN Milano (Italy); Vitillo, R. [INFN Pisa (Italy); Volpi, G. [INFN Frascati (Italy)

    2011-07-01T23:59:59.000Z

    We describe an important advancement for the Associative Memory device (AM). The AM is a VLSI processor for pattern recognition based on Content Addressable Memory (CAM) architecture. The AM is optimized for on-line track finding in high-energy physics experiments. Pattern matching is carried out by finding track candidates in coarse resolution 'roads'. A large AM bank stores all trajectories of interest, called 'patterns', for a given detector resolution. The AM extracts roads compatible with a given event during detector read-out. Two important variables characterize the quality of the AM bank: its 'coverage' and the level of fake roads. The coverage, which describes the geometric efficiency of a bank, is defined as the fraction of tracks that match at least one pattern in the bank. Given a certain road size, the coverage of the bank can be increased just adding patterns to the bank, while the number of fakes unfortunately is roughly proportional to the number of patterns in the bank. Moreover, as the luminosity increases, the fake rate increases rapidly because of the increased silicon occupancy. To counter that, we must reduce the width of our roads. If we decrease the road width using the current technology, the system will become very large and extremely expensive. We propose an elegant solution to this problem: the 'variable resolution patterns'. Each pattern and each detector layer within a pattern will be able to use the optimal width, but we will use a 'don't care' feature (inspired from ternary CAMs) to increase the width when that is more appropriate. In other words we can use patterns of variable shape. As a result we reduce the number of fake roads, while keeping the efficiency high and avoiding excessive bank size due to the reduced width. We describe the idea, the implementation in the new AM design and the implementation of the algorithm in the simulation. Finally we show the effectiveness of the 'variable resolution patterns' idea using simulated high occupancy events in the ATLAS detector. (authors)

  15. Fabrication and characterization of a 0.5-mm lutetium oxyorthosilicate detector array for high-resolution PET applications

    E-Print Network [OSTI]

    Stickel, Jennifer R; Qi, Jinyi; Cherry, Simon R

    2007-01-01T23:59:59.000Z

    for a high resolution PET detector using position sensitive51:2131–2142. 0.5- MM LSO A RRAY FOR PET • Stickel et al.Instrumentation aspects of animal PET. Annu Rev Biomed Eng.

  16. High-resolution calorimetric study of the nematic to smectic- A transition in aligned liquid crystal–aerosil gels

    E-Print Network [OSTI]

    Garland, Carl W.

    High-resolution ac calorimetry has been used to study the nematic to smectic-A (N-SmA) phase transition in the liquid crystal octylcyanobiphenyl (8CB) confined in aligned colloidal aerosil gels. A stable and robust nematic ...

  17. Data report: High-resolution stable isotope stratigraphy of the late Middle Eocene at Site 1051, Blake Nose 

    E-Print Network [OSTI]

    Wade, Bridget S.; Norris, Richard D.; Kroom, Dick

    2000-01-01T23:59:59.000Z

    The primary aim of the this investigation was to examine the stability of subtropical sea-surface temperatures and reconstruct the surfaceto- benthos thermal gradient. High-resolution stable isotopic analyses (?18O and ?13C) were conducted on late...

  18. Monitoring temperate glaciers by high resolution Pol-InSAR data: First analysis of Argentire E-SAR

    E-Print Network [OSTI]

    Boyer, Edmond

    Monitoring temperate glaciers by high resolution Pol-InSAR data: First analysis of Argentière E to measure temperate glacier velocities and surface characteristics by airborne interferometric Alpine glaciers. Simultaneously to the acquisition of repeat pass interferometric, polarimetric and multi

  19. High-resolution shear-wave reflection profiling to image offset in unconsolidated near-surface sediments

    E-Print Network [OSTI]

    Bailey, Bevin

    2014-05-31T23:59:59.000Z

    S-wave reflection profiling has many theoretical advantages, when compared to P-wave profiling, such as high-resolution potential, greater sensitivities to lithologic changes and insensitivity to the water table and pore ...

  20. High-resolution 18F-FDG PET with MRI for monitoring response to treatment in rheumatoid arthritis

    E-Print Network [OSTI]

    2010-01-01T23:59:59.000Z

    of a dedicated breast PET/CT scanner during human imaging. J2]. A high-resolution PET/CT scanner for imaging extremitiesOA). An extremity 18 F-FDG PET/CT scan immediately following

  1. Massive quiescent cores in Orion. IV. Their supercritical state revealed by high resolution ammonia maps

    E-Print Network [OSTI]

    Li, D; Zhang, Q; Chen, W

    2012-01-01T23:59:59.000Z

    We present combined VLA and GBT images of \\ammonia\\ inversion transitions (1,1) and (2,2) toward OMC2 and OMC3. We focus on the relatively quiescent Orion cores, which are away from the Trapezium cluster and have no sign of massive protostars nor evolved star formation, such as IRAS source, water maser, and methanol maser. The 5\\arcsec\\ angular resolution and $0.6 \\rm{}km s^{-1}$ velocity resolution of these data enable us to study the thermal and dynamic state of these cores at $\\sim{}0.02 \\rm{}pc$ scales, comparable to or smaller than those of the current dust continuum surveys. We measure temperatures for a total of 30 cores, with average masses and radii of $11 \\Ms$ and $0.039 \\rm{}pc$, respectively. Compared to other Gould Belt dense cores, the Orion cores have an unusually high gravitational-to-inetic energy ratio (virial mass ratio $R_{vir} > >1$), resembling results for other clouds forming high--mass stars. This results from Orion cores having velocity dispersions similar to those in, e.g., Perseus a...

  2. Diamond-machined ZnSe immersion grating for NIR high-resolution spectroscopy

    SciTech Connect (OSTI)

    Ikeda, Y; Kobayashi, N; Kuzmenko, P J; Little, S L; Yasui, C; Kondo, S; Minami, A; Motohara, K

    2008-07-25T23:59:59.000Z

    ZnSe immersion gratings (n {approx} 2.45) provide the possibility of high-resolution spectroscopy for the near-infrared (NIR) region. Since ZnSe has a lower internal attenuation than other NIR materials, it is most suitable for immersion grating, particularly in short NIR region (0.8-1.4 {micro}m). We are developing an extremely high-resolution spectrograph with {lambda}/{Delta}{lambda} = 100,000, WINERED, customized for the short NIR region, using ZnSe (or ZnS) immersion grating. However, it had been very difficult to make fine grooves on ZnSe substrate with a small pitch of less than 50 {micro}m because ZnSe is a soft/brittle material. We have overcome this problem and successfully machined sharp grooves with fine pitch on ZnSe substrates by nano precision fly-cutting technique at LLNL. The optical testing of the sample grating with HeNe laser shows an excellent performance: the relative efficiency more than 87.4 % at 0.633 {micro}m for a classical grating configuration. The diffraction efficiency when used as an immersion grating is estimated to be more than 65 % at 1 {micro}m. Following this progress, we are about to start machining a grating on a large ZnSe prism with an entrance aperture of 23mm x 50mm and the blaze angle of 70{sup o}.

  3. High resolution interface nanochemistry and structure: Final project report, December 1, 1993--February 28, 1997

    SciTech Connect (OSTI)

    Carpenter, R.W.; Lin, S.H.

    1997-02-27T23:59:59.000Z

    Work includes studies of interface and grain boundary chemistry and structure in silicon nitride matrix/silicon carbide whisker composites, and in monolithic silicon nitride and silicon carbide synthesized by several different methods. Off-stoichiometric, impurity, and sintering aid elemental distributions in these materials (and other ceramics) have been of great interest because of expected effects on properties but these distributions have proven very difficult to measure because the spatial resolution required is high. The authors made a number of these measurements for the first time, using techniques and instrumentation developed here. Interfaces between metals and SiC are the basis for important metal matrix composites and contacts for high temperature SiC-based solid state electronic devices. The authors have investigated ultrapure interfaces between Ti, Hf, Ti-Hf alloys, Pt, and Co and Si-terminated (0001) 6H SiC single crystals for the first time.

  4. High-resolution multi-heterodyne spectroscopy based on Fabry-Perot quantum cascade lasers

    SciTech Connect (OSTI)

    Wang, Yin; Wang, Wen; Wysocki, Gerard, E-mail: gwysocki@princeton.edu [Department of Electrical Engineering, Princeton University, Princeton, New Jersey 08540 (United States); Soskind, Michael G. [Department of Electrical Engineering, Princeton University, Princeton, New Jersey 08540 (United States); Department of Electrical Engineering, Rutgers University, New Brunswick, New Jersy 08901 (United States)

    2014-01-20T23:59:59.000Z

    In this Letter, we present a method of performing broadband mid-infrared spectroscopy with conventional, free-running, continuous wave Fabry-Perot quantum cascade lasers (FP-QCLs). The measurement method is based on multi-heterodyne down-conversion of optical signals. The sample transmission spectrum probed by one multi-mode FP-QCL is down-converted to the radio-frequency domain through an optical multi-heterodyne process using a second FP-QCL as the local oscillator. Both a broadband multi-mode spectral measurement as well as high-resolution (?15?MHz) spectroscopy of molecular absorption are demonstrated and show great potential for development of high performance FP-laser-based spectrometers for chemical sensing.

  5. High Spatial Resolution Fast-Neutron Imaging Detectors for Pulsed Fast-Neutron Transmission Spectroscopy

    E-Print Network [OSTI]

    Mor, I; Bar, D; Feldman, G; Goldberg, M B; Katz, D; Sayag, E; Shmueli, I; Cohen, Y; Tal, A; Vagish, Z; Bromberger, B; Dangendorf, V; Mugai, D; Tittelmeier, K; Weierganz, M

    2009-01-01T23:59:59.000Z

    Two generations of a novel detector for high-resolution transmission imaging and spectrometry of fast-neutrons are presented. These devices are based on a hydrogenous fiber scintillator screen and single- or multiple-gated intensified camera systems (ICCD). This detector is designed for energy-selective neutron radiography with nanosecond-pulsed broad-energy (1 - 10 MeV) neutron beams. Utilizing the Time-of-Flight (TOF) method, such a detector is capable of simultaneously capturing several images, each at a different neutron energy (TOF). In addition, a gamma-ray image can also be simultaneously registered, allowing combined neutron/gamma inspection of objects. This permits combining the sensitivity of the fast-neutron resonance method to low-Z elements with that of gamma radiography to high-Z materials.

  6. High resolution laser induced fluorescence Doppler velocimetry utilizing saturated absorption spectroscopy

    SciTech Connect (OSTI)

    Aramaki, Mitsutoshi [Department of Electrical Engineering and Computer Science, Nagoya University, Nagoya 464-8603 (Japan); Ogiwara, Kohei; Etoh, Shuzo [Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Kasuga 816-8580 (Japan); Yoshimura, Shinji [National Institute for Fusion Science, Toki 509-5292 (Japan); Tanaka, Masayoshi Y. [Department of Advanced Energy Engineering Science, Kyushu University, Kasuga 816-8580 (Japan)

    2009-05-15T23:59:59.000Z

    A high resolution laser induced fluorescence (LIF) system has been developed to measure the flow velocity field of neutral particles in an electron-cyclotron-resonance argon plasma. The flow velocity has been determined by the Doppler shift of the LIF spectrum, which is proportional to the velocity distribution function. Very high accuracy in velocity determination has been achieved by installing a saturated absorption spectroscopy unit into the LIF system, where the absolute value and scale of laser wavelength are determined by using the Lamb dip and the fringes of a Fabry-Perot interferometer. The minimum detectable flow velocity of a newly developed LIF system is {+-}2 m/s, and this performance remains unchanged in a long-time experiment. From the radial measurements of LIF spectra of argon metastable atoms, it is found that there exists an inward flow of neutral particles associated with neutral depletion.

  7. High resolution coherent diffractive imaging with a table-top extreme ultraviolet source

    SciTech Connect (OSTI)

    Vu Le, Hoang, E-mail: vuhoangle@swin.edu.au; Ba Dinh, Khuong; Hannaford, Peter; Van Dao, Lap [Centre for Quantum and Optical Science, Swinburne University of Technology, Melbourne 3122 (Australia)

    2014-11-07T23:59:59.000Z

    We demonstrate a resolution of 45?nm with a sample size down to 3??m × 3??m is achieved in a short exposure time of 2?s, from the diffraction pattern generated by a table-top high harmonic source at around 30?nm. By using a narrow-bandwidth focusing mirror, the diffraction pattern's quality is improved and the required exposure time is significantly reduced. In order to obtain a high quality of the reconstructed image, the ratio of the beam size to the sample size and the curvature of the focused beam need to be considered in the reconstruction process. This new experimental scheme is very promising for imaging sub-10?nm scale objects with a table-top source based on a small inexpensive femtosecond laser system.

  8. High-resolution metagenomics targets major functional types in complex microbial communities

    SciTech Connect (OSTI)

    Kalyuzhnaya, Marina G.; Lapidus, Alla; Ivanova, Natalia; Copeland, Alex C.; McHardy, Alice C.; Szeto, Ernest; Salamov, Asaf; Grigoriev, Igor V.; Suciu, Dominic; Levine, Samuel R.; Markowitz, Victor M.; Rigoutsos, Isidore; Tringe, Susannah G.; Bruce, David C.; Richardson, Paul M.; Lidstrom, Mary E.; Chistoserdova, Ludmila

    2009-08-01T23:59:59.000Z

    Most microbes in the biosphere remain uncultured and unknown. Whole genome shotgun (WGS) sequencing of environmental DNA (metagenomics) allows glimpses into genetic and metabolic potentials of natural microbial communities. However, in communities of high complexity metagenomics fail to link specific microbes to specific ecological functions. To overcome this limitation, we selectively targeted populations involved in oxidizing single-carbon (C{sub 1}) compounds in Lake Washington (Seattle, USA) by labeling their DNA via stable isotope probing (SIP), followed by WGS sequencing. Metagenome analysis demonstrated specific sequence enrichments in response to different C{sub 1} substrates, highlighting ecological roles of individual phylotypes. We further demonstrated the utility of our approach by extracting a nearly complete genome of a novel methylotroph Methylotenera mobilis, reconstructing its metabolism and conducting genome-wide analyses. This approach allowing high-resolution genomic analysis of ecologically relevant species has the potential to be applied to a wide variety of ecosystems.

  9. A high-resolution imaging x-ray crystal spectrometer for high energy density plasmas

    SciTech Connect (OSTI)

    Chen, Hui, E-mail: chen33@llnl.gov, E-mail: bitter@pppl.gov; Magee, E.; Nagel, S. R.; Park, J.; Schneider, M. B.; Stone, G.; Williams, G. J.; Beiersdorfer, P. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550-9234 (United States); Bitter, M., E-mail: chen33@llnl.gov, E-mail: bitter@pppl.gov; Hill, K. W. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Kerr, S. [Department of Applied Science, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada)

    2014-11-15T23:59:59.000Z

    Adapting a concept developed for magnetic confinement fusion experiments, an imaging crystal spectrometer has been designed and tested for HED plasmas. The instrument uses a spherically bent quartz [211] crystal with radius of curvature of 490.8 mm. The instrument was tested at the Titan laser at Lawrence Livermore National Laboratory by irradiating titanium slabs with laser intensities of 10{sup 19}–10{sup 20} W/cm{sup 2}. He-like and Li-like Ti lines were recorded, from which the spectrometer performance was evaluated. This spectrometer provides very high spectral resolving power (E/dE > 7000) while acquiring a one-dimensional image of the source.

  10. SIEMENS ADVANCED QUANTRA FTICR MASS SPECTROMETER FOR ULTRA HIGH RESOLUTION AT LOW MASS

    SciTech Connect (OSTI)

    Spencer, W; Laura Tovo, L

    2008-07-08T23:59:59.000Z

    The Siemens Advanced Quantra Fourier Transform Ion Cyclotron Resonance (FTICR) mass spectrometer was evaluated as an alternative instrument to large double focusing mass spectrometers for gas analysis. High resolution mass spectrometers capable of resolving the common mass isomers of the hydrogen isotopes are used to provide data for accurate loading of reservoirs and to monitor separation of tritium, deuterium, and helium. Conventional double focusing magnetic sector instruments have a resolution that is limited to about 5000. The Siemens FTICR instrument achieves resolution beyond 400,000 and could possibly resolve the tritium ion from the helium-3 ion, which differ by the weight of an electron, 0.00549 amu. Working with Y-12 and LANL, SRNL requested Siemens to modify their commercial Quantra system for low mass analysis. To achieve the required performance, Siemens had to increase the available waveform operating frequency from 5 MHz to 40 MHz and completely redesign the control electronics and software. However, they were able to use the previous ion trap, magnet, passive pump, and piezo-electric pulsed inlet valve design. NNSA invested $1M in this project and acquired four systems, two for Y-12 and one each for SRNL and LANL. Siemens claimed a $10M investment in the Quantra systems. The new Siemens Advanced Quantra demonstrated phenomenal resolution in the low mass range. Resolution greater than 400,000 was achieved for mass 2. The new spectrometer had a useful working mass range to 500 Daltons. However, experiments found that a continuous single scan from low mass to high was not possible. Two useful working ranges were established covering masses 1 to 6 and masses 12 to 500 for our studies. A compromise performance condition enabled masses 1 to 45 to be surveyed. The instrument was found to have a dynamic range of about three orders of magnitude and quantitative analysis is expected to be limited to around 5 percent without using complex fitting algorithms. Analysis of low concentration ions, at the ppm level, required a separate analysis using ion ejection techniques. Chemical ionization due to the formation of the MH{sup +} ion or MD{sup +} increased the complexity of the spectra compared to magnetic sector mass spectra and formation of the protonated or deuterated complex was a dynamic function of the trap ion concentration. This made quantitative measurement more of a challenge. However, the resolution of the instrument was far superior to any other mass spectrometry technique that has been applied to the analysis of the hydrogen isotopes. The piezo-electric picoliter injection device offers a new way of submitting small quantities of atmospheric pressure sample gas for analysis. The new software had many improvements over the previous version but significant flaws in the beta codes remain that make the prototype units less than ideal. The instrument is a promising new technology that experience will likely improve. Unfortunately, Siemens has concluded that the technology will not be a commercial success and has decided to stop producing this product.

  11. Animals In Synchrotrons: Overcoming Challenges For High-Resolution, Live, Small-Animal Imaging

    SciTech Connect (OSTI)

    Donnelley, Martin [Respiratory and Sleep Medicine, Women's and Children's Hospital, Adelaide, South Australia (Australia); Parsons, David [Respiratory and Sleep Medicine, Women's and Children's Hospital, Adelaide, South Australia (Australia); Women's and Children's Health Research Institute, Adelaide, South Australia (Australia); Department of Paediatrics and Reproductive Health, University of Adelaide, South Australia (Australia); Department of Paediatircs Centre for Stem Cell Research, University of Adelaide, South Australia (Australia); Morgan, Kaye [School of Physics, Monash University, Melbourne, Victoria (Australia); Siu, Karen [School of Physics, Monash University, Melbourne, Victoria (Australia); Monash Centre for Synchrotron Science, Monash University, Melbourne, Victoria (Australia)

    2010-07-23T23:59:59.000Z

    Physiological studies in small animals can be complicated, but the complexity is increased dramatically when performing live-animal synchrotron X-ray imaging studies. Our group has extensive experience in high-resolution live-animal imaging at the Japanese SPring-8 synchrotron, primarily examining airways in two-dimensions. These experiments normally image an area of 1.8 mmx1.2 mm at a pixel resolution of 0.45 {mu}m and are performed with live, intact, anaesthetized mice.There are unique challenges in this experimental setting. Importantly, experiments must be performed in an isolated imaging hutch not specifically designed for small-animal imaging. This requires equipment adapted to remotely monitor animals, maintain their anesthesia, and deliver test substances while collecting images. The horizontal synchrotron X-ray beam has a fixed location and orientation that limits experimental flexibility. The extremely high resolution makes locating anatomical regions-of-interest slow and can result in a high radiation dose, and at this level of magnification small animal movements produce motion-artifacts that can render acquired images unusable. Here we describe our experimental techniques and how we have overcome several challenges involved in performing live mouse synchrotron imaging.Experiments have tested different mouse strains, with hairless strains minimizing overlying skin and hair artifacts. Different anesthetics have also be trialed due to the limited choices available at SPring-8. Tracheal-intubation methods have been refined and controlled-ventilation is now possible using a specialized small-animal ventilator. With appropriate animal restraint and respiratory-gating, motion-artifacts have been minimized. The animal orientation (supine vs. head-high) also appears to affect animal physiology, and can alter image quality. Our techniques and image quality at SPring-8 have dramatically improved and in the near future we plan to translate this experience to the Imaging and Medical Beamline at the Australian Synchrotron.Overcoming these challenges has permitted increasingly sophisticated imaging of animals with synchrotron X-rays, and we expect a bright future for these techniques.

  12. Study of Fish Response Using Particle Image Velocimetry and High-Speed, High-Resolution Imaging

    SciTech Connect (OSTI)

    Deng, Zhiqun; Richmond, Marshall C.; Guensch, Gregory R.; Mueller, Robert P.

    2004-10-23T23:59:59.000Z

    Existing literature of previous particle image velocimetry (PIV) studies of fish swimming has been reviewed. Historically, most of the studies focused on the performance evaluation of freely swimming fish. Technological advances over the last decade, especially the development of digital particle image velocimetry (DPIV) technique, make possible more accurate, quantitative descriptions of the flow patterns adjacent to the fish and in the wake behind the fins and tail, which are imperative to decode the mechanisms of drag reduction and propulsive efficiency. For flows generated by different organisms, the related scales and flow regimes vary significantly. For small Reynolds numbers, viscosity dominates; for very high Reynolds numbers, inertia dominates, and three-dimensional complexity occurs. The majority of previous investigations dealt with the lower end of Reynolds number range. The fish of our interest, such as rainbow trout and spring and fall chinook salmon, fall into the middle range, in which neither viscosity nor inertia is negligible, and three-dimensionality has yet to dominate. Feasibility tests have proven the applicability of PIV to flows around fish. These tests have shown unsteady vortex shedding in the wake, high vorticity region and high stress region, with the highest in the pectoral area. This evident supports the observations by Nietzel et al. (2000) and Deng et al. (2004) that the operculum are most vulnerable to damage from the turbulent shear flow, because they are easily pried open, and the large vorticity and shear stress can lift and tear off scales, rupture or dislodge eyes, and damage gills. In addition, the unsteady behavior of the vortex shedding in the wake implies that injury to fish by the instantaneous flow structures would likely be much higher than the injury level estimated using the average values of the dynamics parameters. Based on existing literature, our technological capability, and relevance and practicability to Department of Energy's Hydropower Program, we identified three major research areas of interest: free swimming, the boundary layer over fish, and kinematic response of fish. We propose that the highest priority is to characterize the kinematic response of fish to different turbulent environments such as high shear/turbulence and hydrodynamic disturbances created by solid structures such as deflector and turbine runner blade; the next priority is to map the boundary layer over swimming fish; the last is to document the behavior of freely swimming fish, focusing on fish of our interest. Grid turbulence and Karman vortex street will be employed to map the boundary layers over fish and investigate the effects of environmental disturbances on the swimming performance of fish, because they are well established and documented in engineering literature and are representative of fish's swimming environments. Extreme conditions characteristic of turbine environments, such as strong shear environment and collision, will be investigated. Through controlled laboratory studies, the fish injury mechanism from different sources will be evaluated in isolation. The major goals are to: gain first-hand knowledge of the biological effects under such extreme hydraulic environments in which fish could lack the capability to overcome the perturbations and be vulnerable to injury; Better understand field results by integrating the laboratory studies with the responses of sensor fish device; More importantly, provide well-defined validation cases and boundary conditions for geometry-based computational fluid-structure interaction modeling in order to simulate the complex hydraulic environments in advanced hydropower systems and their effects on fish, greatly enhancing the potential to use CFD as a bio-hydraulic design alternative.

  13. High-resolution observations of active region moss and its dynamics

    E-Print Network [OSTI]

    Morton, R J

    2014-01-01T23:59:59.000Z

    The \\textit{High resolution Coronal Imager (Hi-C)} has provided the sharpest view of the EUV corona to date. In this paper we exploit its impressive resolving power to provide the first analysis of the fine-scale structure of moss in an active region. The data reveal that the moss is made up of a collection of fine threads, that have widths with a mean and standard deviation of $440\\pm190$~km (Full Width Half Maximum). {The brightest moss emission is located at the visible head of the fine-scale structure and the fine structure appears to extend into the lower solar atmosphere.} The emission decreases along the features implying the lower sections are most likely dominated by cooler transition region plasma. These threads appear to be the cool, lower legs of the hot loops. In addition, the increased resolution allows for the first direct observation {of physical displacements of the moss fine-structure in a direction transverse to its central axis. Some of these transverse displacements demonstrate periodic b...

  14. High resolution transmission electron microscopy of melamine-formaldehyde aerogels and silica aerogels

    SciTech Connect (OSTI)

    Ruben, G.C. (Dartmouth Coll., Hanover, NH (United States). Dept. of Biological Sciences)

    1991-09-01T23:59:59.000Z

    The goal of the high resolution transmission electron microscopy (HRTEM) was to image the structure of two tetramethyl orthosilicate (TMOS) and two melamine-formaldehyde (MF) aerogels at the single polymer chain level{sup 1,2}. With this level of structural resolution we hoped to interrelate each aerogel's structure with its physical properties and its method of synthesis. Conventional single-step base catalysed TMOS aerogels show strings of spheroidal particles linked together with minimal necking. The spheroidal particles range from 86--132 {Angstrom} and average 113{plus minus}10 {Angstrom} in diameter{sup 2}. In contrast the TMOS aerogels reported on here were made by a two step method. After extended silica chains are grown in solution under acidic conditions with a substoichiometric amount of water, the reaction is stopped and the methanol hydrolysed from TMOS is removed. Then base catalysis and additional water are added to cause gel formation is a nonalcoholic solvent. The MF aerogels were prepared for HRTEM by fracturing them on a stereo microscope stage with razor knife so that fractured pieces with smooth flat surfaces could be selected for platinum-carbon replication. The two silica (TMOS) aerogels were both transparent and difficult to see. These aerogels were fractured on a stereo microscope stage with tweezers. 6 refs., 4 figs.

  15. Submillimeter Array High-angular Resolution Observations of the Monoceros R2 Star Forming Cluster

    E-Print Network [OSTI]

    Dierickx, Marion; Rivilla, Victor; Zhang, Qizhou

    2015-01-01T23:59:59.000Z

    We present the first high-angular resolution study of the MonR2 star-forming complex carried out with the Submillimeter Array at (sub-)millimeter wavelengths. We image the continuum and molecular line emission toward the young stellar objects in MonR2 at 0.85mm and 1.3mm, with resolutions ranging from 0.5" to ~3". While free-free emission dominates the IRS1 and IRS2 continuum, dust thermal emission prevails for IRS3 and IRS5, giving envelope masses of ~0.1-0.3 M_Sun. IRS5 splits into at least two sub-arcsecond scale sources, IRS5B and the more massive IRS5A. Our 12CO(2-1) images reveal 11 previously unknown molecular outflows in the MonR2 clump. Comparing these outflows with known IR sources in the IRS5 and IRS3 subclusters allows for tentative identification of driving stars. Line images of molecular species such as CH3CN or CH3OH show that, besides IRS3 (a well-known hot molecular core), IRS5 is also a chemically active source in the region. The gas excitation temperature derived from CH3CN lines toward IRS...

  16. High-resolution spectra of solar magnetic features. I. Analysis of penumbral fine structure

    SciTech Connect (OSTI)

    Lites, B.W.; Skumanich, A.; Scharmer, G.B. (High Altitude Observatory, Boulder, CO (USA) Kungliga Svenska Vetenskapsakademien, Stockholm (Sweden))

    1990-05-01T23:59:59.000Z

    The Swedish Vacuum Telescope on La Palma was used to obtain spectra of the magnetic-sensitive Fe I 630.25 nm line under conditions of exceptional angular resolution (0.32 arcsec) and high spectral resolution (FWHM 2.5 pm). Simultaneous 0.02 s CCD exposures of both the spectrum and the slit-jaw image effectively 'freeze' the atmospheric seeing motions and permit unambiguous identification of the spectra of the various penumbral structures. These spectra reveal the magnetic field strength in penumbral filaments through an intensity fit of the Zeeman splitting of this line. The observations show that: (1) the field strength varies from about 2100 G near the umbra-penumbra boundary to about 900 G at the outer edge of the penumbra, (2) the observed fluctuation of penumbral magnetic field is much less dramatic than the fluctuation in intensity, (3) there is a suggestion of a rapid change in field inclination between some light and dark filaments near the edge of the penumbra, and (4) there is no obvious correlation between Doppler shift (in part due to the Evershed flow) and filament intensity. 43 refs.

  17. A compact and miniaturized high resolution capacitance dilatometer for measuring thermal expansion and magnetostriction

    SciTech Connect (OSTI)

    Kuechler, R.; Bauer, T.; Brando, M.; Steglich, F. [Max Planck Institute for Chemical Physics of Solids, Noethnitzer Str. 40, 01187 Dresden (Germany)

    2012-09-15T23:59:59.000Z

    We describe the design, construction, calibration, and two different applications of a miniature capacitance dilatometer. The device is suitable for thermal expansion and magnetostriction measurements from 300 K down to about 25 mK, with a resolution of 0.02 A at low temperatures. The main body of the dilatometer is fabricated from a single block of a Be-Cu alloy by electrical discharge milling. This creates an extremely compact high-resolution measuring cell. We have successfully tested and operated dilatometers of this new type with the commonly used physical property measurement system by quantum design, as well as with several other cryogenic refrigeration systems down to 25 mK and in magnetic fields up to 20 T. Here, the capacitance is measured with a commercially available capacitance bridge. Using a piezoelectric rotator from Attocube Systems, the cell can be rotated at T= 25 mK inside of an inner vacuum chamber of 40 mm diameter. The miniaturized design for the one-axis rotation setup allows a rotation of 360 Degree-Sign .

  18. Development of Advanced Optics and High Resolution Instrumentation for Mass Spectrometry Based Proteomics

    E-Print Network [OSTI]

    Sherrod, Stacy D.

    2010-01-14T23:59:59.000Z

    ) improving the analytical figures of merit (i.e., spatial resolution, analysis time) by implementing a spatially dynamic optical system, and (3) increasing both mass spectral resolution and ion detection sensitivity by modifying a commercial time...

  19. Technique for continuous high-resolution analysis of trace substances in firn and ice cores

    SciTech Connect (OSTI)

    Roethlisberger, R.; Bigler, M.; Hutterli, M.; Sommer, S.; Stauffer, B.; Junghans, H.G.; Wagenbach, D.

    2000-01-15T23:59:59.000Z

    The very successful application of a CFA (Continuous flow analysis) system in the GRIP project (Greenland Ice Core Project) for high-resolution ammonium, calcium, hydrogen peroxide, and formaldehyde measurements along a deep ice core led to further development of this analysis technique. The authors included methods for continuous analysis technique. The authors included methods for continuous analysis of sodium, nitrate, sulfate, and electrolytical conductivity, while the existing methods have been improved. The melting device has been optimized to allow the simultaneous analysis of eight components. Furthermore, a new melter was developed for analyzing firn cores. The system has been used in the frame of the European Project for Ice Coring in Antarctica (EPICA) for in-situ analysis of several firn cores from Dronning Maud Land, Antarctica, and for the new ice core drilled at Dome C, Antarctica.

  20. Solar wind turbulence from MHD to sub-ion scales: high-resolution hybrid simulations

    E-Print Network [OSTI]

    Franci, Luca; Matteini, Lorenzo; Landi, Simone; Hellinger, Petr

    2015-01-01T23:59:59.000Z

    We present results from a high-resolution and large-scale hybrid (fluid electrons and particle-in-cell protons) two-dimensional numerical simulation of decaying turbulence. Two distinct spectral regions (separated by a smooth break at proton scales) develop with clear power-law scaling, each one occupying about a decade in wave numbers. The simulation results exhibit simultaneously several properties of the observed solar wind fluctuations: spectral indices of the magnetic, kinetic, and residual energy spectra in the magneto-hydrodynamic (MHD) inertial range along with a flattening of the electric field spectrum, an increase in magnetic compressibility, and a strong coupling of the cascade with the density and the parallel component of the magnetic fluctuations at sub-proton scales. Our findings support the interpretation that in the solar wind large-scale MHD fluctuations naturally evolve beyond proton scales into a turbulent regime that is governed by the generalized Ohm's law.

  1. Deflection Measurements of a Thermally Simulated Nuclear Core using a High-Resolution CCD-Camera

    SciTech Connect (OSTI)

    Stanojev, B.J. [Marshall Space Flight Center, National Aeronautics and Space Administration, Huntsville, Al, 35812 (United States); Houts, M. [Los Alamos National Laboratory, Department of Energy, Los Alamos, NM, 87545 (United States)

    2004-07-01T23:59:59.000Z

    Space fission systems under consideration for near-term missions all use compact, fast-spectrum reactor cores. Reactor dimensional change with increasing temperature, which affects neutron leakage, is the dominant source of reactivity feedback in these systems. Accurately measuring core dimensional changes during realistic non-nuclear testing is therefore necessary in predicting the system 'nuclear' equivalent behavior. This paper discusses one key technique being evaluated for measuring such changes. The proposed technique is to use a Charged Couple Device (CCD) sensor to obtain deformation readings of electrically heated prototypic reactor core geometry. This paper introduces a technique by which a single high spatial resolution CCD camera is used to measure core deformation in Real-Time (RT). Initial system checkout results are presented along with a discussion on how additional cameras could be used to achieve a three-dimensional deformation profile of the core during test. (authors)

  2. OASIS High-Resolution Integral Field Spectroscopy of the SAURON Ellipticals and Lenticulars

    E-Print Network [OSTI]

    McDermid, R; Cappellari, M; Kuntschner, H; Bacon, R; Bureau, M; Copin, Y; Davies, R L; Falcon-Barroso, J; Ferruit, P; Krajnovic, D; Peletier, R F; Shapiro, K; Wernli, F; De Zeeuw, P T

    2003-01-01T23:59:59.000Z

    We present a summary of high-spatial resolution follow-up observations of the elliptical (E) and lenticular (S0) galaxies in the SAURON survey using the OASIS integral field spectrograph. The OASIS observations explore the central 8x10" regions of these galaxies using a spatial sampling four times higher than SAURON, often revealing previously undiscovered features. Around 75% (31/48) of the SAURON E/S0s with central velocity dispersion >= 120 km/s were observed with OASIS, covering well the original SAURON representative sample. We present here an overview of this follow-up survey, and some preliminary results on individual objects, including a previously unreported counter-rotating core in NGC 4382; the decoupled stellar and gas velocity fields of NGC 2768; and the strong age gradient towards the centre of NGC 3489.

  3. OASIS High-Resolution Integral Field Spectroscopy of the SAURON Ellipticals and Lenticulars

    E-Print Network [OSTI]

    R. McDermid; E. Emsellem; M. Cappellari; H. Kuntschner; R. Bacon; M. Bureau; Y. Copin; R. L. Davies; J. Falcon-Barroso; P. Ferruit; D. Krajnovic; R. F. Peletier; K. Shapiro; F. Wernli; P. T. de Zeeuw

    2003-11-10T23:59:59.000Z

    We present a summary of high-spatial resolution follow-up observations of the elliptical (E) and lenticular (S0) galaxies in the SAURON survey using the OASIS integral field spectrograph. The OASIS observations explore the central 8x10" regions of these galaxies using a spatial sampling four times higher than SAURON, often revealing previously undiscovered features. Around 75% (31/48) of the SAURON E/S0s with central velocity dispersion >= 120 km/s were observed with OASIS, covering well the original SAURON representative sample. We present here an overview of this follow-up survey, and some preliminary results on individual objects, including a previously unreported counter-rotating core in NGC 4382; the decoupled stellar and gas velocity fields of NGC 2768; and the strong age gradient towards the centre of NGC 3489.

  4. Compact, high-resolution, gamma ray imaging for scintimammography and other medical diagostic applications

    DOE Patents [OSTI]

    Majewski, Stanislaw (Grafton, VA); Weisenberger, Andrew G. (Grafton, VA); Wojcik, Randolph F. (Yorktown, VA); Steinbach, Daniela (Williamsburg, VA)

    1999-01-01T23:59:59.000Z

    A high resolution gamma ray imaging device includes an aluminum housing, a lead screen collimator at an opened end of the housing, a crystal scintillator array mounted behind the lead screen collimator, a foam layer between the lead screen collimator and the crystal scintillator array, a photomultiplier window coupled to the crystal with optical coupling grease, a photomultiplier having a dynode chain body and a base voltage divider with anodes, anode wire amplifiers each connected to four anodes and a multi pin connector having pin connections to each anode wire amplifier. In one embodiment the crystal scintillator array includes a yttrium aluminum perovskite (YAP) crystal array. In an alternate embodiment, the crystal scintillator array includes a gadolinium oxyorthosilicate (GSO) crystal array.

  5. Optical multichannel analyzer-based high-resolution, multipoint spectroscopic apparatus

    SciTech Connect (OSTI)

    Antoniades, J.A.; Peyser, T.

    1987-02-01T23:59:59.000Z

    A high-wavelength resolution (..delta..lambdaless than or equal to0.02 A) spectroscopic apparatus has been developed and applied to the measurements of spectral line profiles emitted by thermonuclear plasmas yielding important plasma parameters, such as ion temperature and fluid velocity. The experimental apparatus consists of a spectrometer, an optical multichannel analyzer (OMA), and a lens. It allows precise wavelength measurements (..delta..lambda/sub error/less than or equal to0.02 A) when a computer and a ThI electrodeless discharge lamp (EDL) are used to calibrate the instrument. The apparatus yields single-shot space and time-resolved spectra for radiation in the 2000--8000-A range.

  6. Recent results on high resolution hypernuclear spectroscopy by electroproduction at Jefferson Lab, Hall A

    SciTech Connect (OSTI)

    F. Garibaldi; H. Breuer; P. Brindza; P. Bydzovski; G. Chang; E. Cisbani; S. Colilli; F. Cusanno; R. De Leo; G. De Cataldo; K. De Jager; R. Feuerbach; E. Folts; R. Fratoni; S. Frullani; F. Giuliani; M. Gricia; D. Higinbotham; M. Iodice; B. Kross; L. Lagamba; J.J.Le Rose; M. Lucentini; P. Markowitz; S. Marrone; R. Michaels; E. Nappi; Y. Qiang; B. Reitz; F. Santavenere; J. Segal; M. Sotona; G.M.Urciuoli; P. Veneroni; B.Wojtsekhowski; C. Zorn

    2005-12-01T23:59:59.000Z

    The first ''systematic'' study of 1 p shell hypernuclei with electromagnetic probes has started in Hall A at Jefferson Lab [?]. The aim is to perform hypernuclear high resolution spectroscopy by the electroproduction of strangeness on four 1p-shell targets: 12C, 9Be, 16O, 7Li. The first part of the experiment on 12C and 9Be has been performed in 2004, the second part (16O and 7Li) is scheduled for June 2005. To overcome the major experimental difficulties, namely the low counting rate and the challenging Particle IDentification (PID), two septum magnets and a Ring Imaging CHerenkov (RICH) detector had to be added to the existing apparatus. After underlining the particular role the electroproduction reaction plays in hypernuclear physics we describe the challenging modifications of the Hall A apparatus. Preliminary results on 12C and 9Be are presented.

  7. Accurate Gravities of F, G, and K stars from High Resolution Spectra Without External Constraints

    E-Print Network [OSTI]

    Brewer, John M; Basu, Sarbani; Valenti, Jeff A; Piskunov, Nikolai

    2015-01-01T23:59:59.000Z

    We demonstrate a new procedure to derive accurate and precise surface gravities from high resolution spectra without the use of external constraints. Our analysis utilizes Spectroscopy Made Easy (SME) with robust spectral line constraints and uses an iterative process to mitigate degeneracies in the fitting process. We adopt an updated radiative transfer code, a new treatment for neutral perturber broadening, a line list with multiple gravity constraints and separate fitting for global stellar properties and abundance determinations. To investigate the sources of temperature dependent trends in determining log g noted in previous studies, we obtained Keck HIRES spectra of 42 Kepler asteroseismic stars. In comparison to asteroseismically determined log g our spectroscopic analysis has a constant offset of 0.01 dex with a root mean square (RMS) scatter of 0.05 dex. We also analyzed 30 spectra which had published surface gravities determined using the $a/R_*$ technique from planetary transits and found a constan...

  8. A low-cost, high-resolution, video-rate imaging optical radar

    SciTech Connect (OSTI)

    Sackos, J.T.; Nellums, R.O.; Lebien, S.M.; Diegert, C.F. [Sandia National Labs., Albuquerque, NM (United States); Grantham, J.W.; Monson, T. [Air Force Research Lab., Eglin AFB, FL (United States)

    1998-04-01T23:59:59.000Z

    Sandia National Laboratories has developed a unique type of portable low-cost range imaging optical radar (laser radar or LADAR). This innovative sensor is comprised of an active floodlight scene illuminator and an image intensified CCD camera receiver. It is a solid-state device (no moving parts) that offers significant size, performance, reliability, and simplicity advantages over other types of 3-D imaging sensors. This unique flash LADAR is based on low cost, commercially available hardware, and is well suited for many government and commercial uses. This paper presents an update of Sandia`s development of the Scannerless Range Imager technology and applications, and discusses the progress that has been made in evolving the sensor into a compact, low, cost, high-resolution, video rate Laser Dynamic Range Imager.

  9. High resolution structure of the large ribosomal subunit from a Mesophilic Eubacterium

    SciTech Connect (OSTI)

    Harms, Joerg; Schluenzen, Frank; Zarivach, Raz; Bashan, Anat; Gat, Sharon; Agmon, Ilana; Bartels, Heike; Franceschi, Francois; Yonath, Ada (Weizmann Inst Israel); (Mac Planck Germany); (Max Planck Germany)

    2009-10-07T23:59:59.000Z

    We describe the high resolution structure of the large ribosomal subunit from Deinococcus radiodurans (D50S), a gram-positive mesophile suitable for binding of antibiotics and functionally relevant ligands. The over-all structure of D50S is similar to that from the archae bacterium Haloarcula marismortui (H50S); however, a detailed comparison revealed significant differences, for example, in the orientation of nucleotides in peptidyl transferase center and in the structures of many ribosomal proteins. Analysis of ribosomal features involved in dynamic aspects of protein biosynthesis that are partially or fully disordered in H50S revealed the conformations of intersubunit bridges in unbound subunits, suggesting how they may change upon subunit association and how movements of the L1-stalk may facilitate the exit of tRNA.

  10. A high resolution finite volume method for efficient parallel simulation of casting processes on unstructured meshes

    SciTech Connect (OSTI)

    Kothe, D.B.; Turner, J.A.; Mosso, S.J. [Los Alamos National Lab., NM (United States); Ferrell, R.C. [Cambridge Power Computer Assoc. (United States)

    1997-03-01T23:59:59.000Z

    We discuss selected aspects of a new parallel three-dimensional (3-D) computational tool for the unstructured mesh simulation of Los Alamos National Laboratory (LANL) casting processes. This tool, known as {bold Telluride}, draws upon on robust, high resolution finite volume solutions of metal alloy mass, momentum, and enthalpy conservation equations to model the filling, cooling, and solidification of LANL castings. We briefly describe the current {bold Telluride} physical models and solution methods, then detail our parallelization strategy as implemented with Fortran 90 (F90). This strategy has yielded straightforward and efficient parallelization on distributed and shared memory architectures, aided in large part by new parallel libraries {bold JTpack9O} for Krylov-subspace iterative solution methods and {bold PGSLib} for efficient gather/scatter operations. We illustrate our methodology and current capabilities with source code examples and parallel efficiency results for a LANL casting simulation.

  11. High-resolution structure of a retroviral protease folded as a monomer

    SciTech Connect (OSTI)

    Gilski, Miroslaw [A. Mickiewicz University, 60-780 Poznan (Poland); Polish Academy of Sciences, 61-704 Poznan (Poland); Kazmierczyk, Maciej; Krzywda, Szymon [A. Mickiewicz University, 60-780 Poznan (Poland); Zábranská, Helena [Academy of Sciences of the Czech Republic, 166 10 Prague (Czech Republic); Cooper, Seth; Popovi?, Zoran [University of Washington, Box 352350, Seattle, WA 98195 (United States); Khatib, Firas; DiMaio, Frank; Thompson, James; Baker, David [University of Washington, Box 357350, Seattle, WA 98195 (United States); Pichová, Iva [Academy of Sciences of the Czech Republic, 166 10 Prague (Czech Republic); Jaskolski, Mariusz, E-mail: mariuszj@amu.edu.pl [A. Mickiewicz University, 60-780 Poznan (Poland); Polish Academy of Sciences, 61-704 Poznan (Poland)

    2011-11-01T23:59:59.000Z

    The crystal structure of Mason–Pfizer monkey virus protease folded as a monomer has been solved by molecular replacement using a model generated by players of the online game Foldit. The structure shows at high resolution the details of a retroviral protease folded as a monomer which can guide rational design of protease dimerization inhibitors as retroviral drugs. Mason–Pfizer monkey virus (M-PMV), a D-type retrovirus assembling in the cytoplasm, causes simian acquired immunodeficiency syndrome (SAIDS) in rhesus monkeys. Its pepsin-like aspartic protease (retropepsin) is an integral part of the expressed retroviral polyproteins. As in all retroviral life cycles, release and dimerization of the protease (PR) is strictly required for polyprotein processing and virion maturation. Biophysical and NMR studies have indicated that in the absence of substrates or inhibitors M-PMV PR should fold into a stable monomer, but the crystal structure of this protein could not be solved by molecular replacement despite countless attempts. Ultimately, a solution was obtained in mr-rosetta using a model constructed by players of the online protein-folding game Foldit. The structure indeed shows a monomeric protein, with the N- and C-termini completely disordered. On the other hand, the flap loop, which normally gates access to the active site of homodimeric retropepsins, is clearly traceable in the electron density. The flap has an unusual curled shape and a different orientation from both the open and closed states known from dimeric retropepsins. The overall fold of the protein follows the retropepsin canon, but the C{sup ?} deviations are large and the active-site ‘DTG’ loop (here NTG) deviates up to 2.7 Å from the standard conformation. This structure of a monomeric retropepsin determined at high resolution (1.6 Å) provides important extra information for the design of dimerization inhibitors that might be developed as drugs for the treatment of retroviral infections, including AIDS.

  12. Investigation of the Behavior of Ethylene Molecular Films Using High Resolution Adsorp

    SciTech Connect (OSTI)

    Barbour, Andi M [ORNL; Telling, Mark T. [ISIS Facility, Rutherford Appleton Laboratory; Larese, John Z [ORNL

    2010-01-01T23:59:59.000Z

    The wetting behavior of ethylene adsorbed on MgO(100) was investigated from 83-135 K using high resolution volumetric adsorption isotherms. The results are compared to ethylene adsorption on graphite, a prototype adsorption system, in an effort to gain further insight into the forces that drive the observed film growth. Layering transitions for ethylene on MgO(100) are observed below the bulk triple point of ethylene (T=104.0 K). The formation of three discrete adlayers is observed on the MgO(100) surface; onset of the second and third layers occurs at 79.2 ( 1.3 K and 98.3(0.9 K, respectively. Thermodynamic quantities such as differential enthalpy and entropy, heat of adsorption, and isosteric heat of adsorption are determined and compared to the previously published values for ethylene on graphite. The average area occupied by a ethylene molecule on MgO(100) is 22.6 ( 1.1A 2 molecule-1. The locations of two phase transitions are identified (i.e., layer critical temperatures at Tc2 (n=1) at 108.6 ( 1.7 K and Tc2 (n=2) at 116.5 ( 1.2 K) and a phase diagram is proposed. Preliminary neutron diffraction measurements reveal evidence of a monolayer solid with a lattice constant of 4.2A . High resolution INS measurements show that the onset to dynamical motion and monolayer melting take place at 35 K and 65 K, respectively. The data reported here exhibit a striking similarity to ethylene on graphite which suggests that molecule-molecule interactions play an important role in determining the physical properties and growth of molecularly thin ethylene films.

  13. High-Resolution Fast-Neutron Spectrometry for Arms Control and Treaty Verification

    SciTech Connect (OSTI)

    David L. Chichester; James T. Johnson; Edward H. Seabury

    2012-07-01T23:59:59.000Z

    Many nondestructive nuclear analysis techniques have been developed to support the measurement needs of arms control and treaty verification, including gross photon and neutron counting, low- and high-resolution gamma spectrometry, time-correlated neutron measurements, and photon and neutron imaging. One notable measurement technique that has not been extensively studied to date for these applications is high-resolution fast-neutron spectrometry (HRFNS). Applied for arms control and treaty verification, HRFNS has the potential to serve as a complimentary measurement approach to these other techniques by providing a means to either qualitatively or quantitatively determine the composition and thickness of non-nuclear materials surrounding neutron-emitting materials. The technique uses the normally-occurring neutrons present in arms control and treaty verification objects of interest as an internal source of neutrons for performing active-interrogation transmission measurements. Most low-Z nuclei of interest for arms control and treaty verification, including 9Be, 12C, 14N, and 16O, possess fast-neutron resonance features in their absorption cross sections in the 0.5- to 5-MeV energy range. Measuring the selective removal of source neutrons over this energy range, assuming for example a fission-spectrum starting distribution, may be used to estimate the stoichiometric composition of intervening materials between the neutron source and detector. At a simpler level, determination of the emitted fast-neutron spectrum may be used for fingerprinting 'known' assemblies for later use in template-matching tests. As with photon spectrometry, automated analysis of fast-neutron spectra may be performed to support decision making and reporting systems protected behind information barriers. This paper will report recent work at Idaho National Laboratory to explore the feasibility of using HRFNS for arms control and treaty verification applications, including simulations and experiments, using fission-spectrum neutron sources to assess neutron transmission through composite low-Z attenuators.

  14. COMPLEX ORGANIC MOLECULES AT HIGH SPATIAL RESOLUTION TOWARD ORION-KL. I. SPATIAL SCALES

    SciTech Connect (OSTI)

    Widicus Weaver, Susanna L. [Department of Chemistry, Emory University, Atlanta, GA 30322 (United States); Friedel, Douglas N., E-mail: susanna.widicus.weaver@emory.edu, E-mail: friedel@astro.illinois.edu [Department of Astronomy, University of Illinois, 1002 West Green Street, Urbana, IL 61801 (United States)

    2012-08-01T23:59:59.000Z

    Here we present high spatial resolution (<1'') observations of molecular emission in Orion-KL conducted using the Combined Array for Research in Millimeter-wave Astronomy. This work was motivated by recent millimeter continuum imaging studies of this region conducted at a similarly high spatial resolution, which revealed that the bulk of the emission arises from numerous compact sources, rather than the larger-scale extended structures typically associated with the Orion Hot Core and Compact Ridge. Given that the spatial extent of molecular emission greatly affects the determination of molecular abundances, it is important to determine the true spatial scale for complex molecules in this region. Additionally, it has recently been suggested that the relative spatial distributions of complex molecules in a source might give insight into the chemical mechanisms that drive complex chemistry in star-forming regions. In order to begin to address these issues, this study seeks to determine the spatial distributions of ethyl cyanide [C{sub 2}H{sub 5}CN], dimethyl ether [(CH{sub 3}){sub 2}O], methyl formate [HCOOCH{sub 3}], formic acid [HCOOH], acetone [(CH{sub 3}){sub 2}CO], SiO, methanol [CH{sub 3}OH], and methyl cyanide [CH{sub 3}CN] in Orion-KL at {lambda} = 3 mm. We find that for all observed molecules, the molecular emission arises from multiple components of the cloud that include a range of spatial scales and physical conditions. Here, we present the results of these observations and discuss the implications for studies of complex molecules in star-forming regions.

  15. Research on Subwavelength Microphtonic Sensors for In-situ Monitoring with High Spatial and Temporal Resolution in Manufacturing Environments

    E-Print Network [OSTI]

    Li, Xiaochun; Wong, Chee Wei; Dornfeld, David; Thomas, Brian

    2006-01-01T23:59:59.000Z

    Service, and Manufacturing Grantees and Research Conference,Service, and Manufacturing Grantees and Research Conference,Service, and Manufacturing Grantees and Research Conference,

  16. High-resolution Tangential AXUV Arrays for Radiated Power Density Measurements on NSTX-U

    SciTech Connect (OSTI)

    Delgado-Aparicio, L [PPPL; Bell, R E [PPPL; Faust, I [MIT; Tritz, K [The Johns Hopkins University, Baltimore, MD, 21209, USA; Diallo, A [PPPL; Gerhardt, S P [PPPL; Kozub, T A [PPPL; LeBlanc, B P [PPPL; Stratton, B C [PPPL

    2014-07-01T23:59:59.000Z

    Precise measurements of the local radiated power density and total radiated power are a matter of the uttermost importance for understanding the onset of impurity-induced instabilities and the study of particle and heat transport. Accounting of power balance is also needed for the understanding the physics of various divertor con#12;gurations for present and future high-power fusion devices. Poloidal asymmetries in the impurity density can result from high Mach numbers and can impact the assessment of their flux-surface-average and hence vary the estimates of P[sub]rad (r, t) and (Z[sub]eff); the latter is used in the calculation of the neoclassical conductivity and the interpretation of non-inductive and inductive current fractions. To this end, the bolometric diagnostic in NSTX-U will be upgraded, enhancing the midplane coverage and radial resolution with two tangential views, and adding a new set of poloidally-viewing arrays to measure the 2D radiation distribution. These systems are designed to contribute to the near- and long-term highest priority research goals for NSTX-U which will integrate non-inductive operation at reduced collisionality, with high-pressure, long energy-confinement-times and a divertor solution with metal walls.

  17. Appending High-Resolution Elevation Data to GPS Speed Traces for Vehicle Energy Modeling and Simulation

    SciTech Connect (OSTI)

    Wood, E.; Burton, E.; Duran, A.; Gonder, J.

    2014-06-01T23:59:59.000Z

    Accurate and reliable global positioning system (GPS)-based vehicle use data are highly valuable for many transportation, analysis, and automotive considerations. Model-based design, real-world fuel economy analysis, and the growing field of autonomous and connected technologies (including predictive powertrain control and self-driving cars) all have a vested interest in high-fidelity estimation of powertrain loads and vehicle usage profiles. Unfortunately, road grade can be a difficult property to extract from GPS data with consistency. In this report, we present a methodology for appending high-resolution elevation data to GPS speed traces via a static digital elevation model. Anomalous data points in the digital elevation model are addressed during a filtration/smoothing routine, resulting in an elevation profile that can be used to calculate road grade. This process is evaluated against a large, commercially available height/slope dataset from the Navteq/Nokia/HERE Advanced Driver Assistance Systems product. Results will show good agreement with the Advanced Driver Assistance Systems data in the ability to estimate road grade between any two consecutive points in the contiguous United States.

  18. Modelling high resolution Echelle spectrographs for calibrations: Hanle Echelle spectrograph, a case study

    E-Print Network [OSTI]

    Chanumolu, Anantha; Thirupathi, Sivarani

    2015-01-01T23:59:59.000Z

    We present a modelling scheme that predicts the centroids of spectral line features for a high resolution Echelle spectrograph to a high accuracy. Towards this, a computing scheme is used, whereby any astronomical spectrograph can be modelled and controlled without recourse to a ray tracing program. The computations are based on paraxial ray trace and exact corrections added for certain surface types and Buchdahl aberration coefficients for complex modules. The resultant chain of paraxial ray traces and corrections for all relevant components is used to calculate the location of any spectral line on the detector under all normal operating conditions with a high degree of certainty. This will allow a semi-autonomous control using simple in-house, programming modules. The scheme is simple enough to be implemented even in a spreadsheet or in any scripting language. Such a model along with an optimization routine can represent the real time behaviour of the instrument. We present here a case study for Hanle Echel...

  19. COMPARISON OF WIND AND WIND SHEAR CLIMATOLOGIES DERIVED FROM HIGH-RESOLUTION RADIOSONDES AND THE ECMWF MODEL

    E-Print Network [OSTI]

    Stoffelen, Ad

    COMPARISON OF WIND AND WIND SHEAR CLIMATOLOGIES DERIVED FROM HIGH-RESOLUTION RADIOSONDES wind and its vertical gradient, i.e. wind-shear, is characterized as a function of climate region. For a better representation of the average atmospheric wind and shear and their variabilities, high

  20. HIGH-RESOLUTION SPECTROSCOPIC IMAGING OF CO IN A z = 4.05 PROTO-CLUSTER

    SciTech Connect (OSTI)

    Hodge, J. A.; Walter, F. [Max-Planck Institute for Astronomy, Königstuhl 17, D-69117 Heidelberg (Germany); Carilli, C. L. [National Radio Astronomy Observatory, P.O. Box 0, Socorro, NM 87801-0387 (United States); Daddi, E. [CEA, Laboratoire AIM-CNRS, Université Paris Diderot, Irfu/SAp, Orme des Merisiers, F-91191 Gif-sur-Yvette (France); Riechers, D., E-mail: hodge@mpia.de [Department of Astronomy, California Institute of Technology, MC 249-17, 1200 East California Boulevard, Pasadena, CA 91125 (United States)

    2013-10-10T23:59:59.000Z

    We present a study of the formation of clustered, massive galaxies at large look-back times via spectroscopic imaging of CO in the unique GN20 proto-cluster at z = 4.05. Existing observations show that this is a dense concentration of gas-rich, very active star forming galaxies, including multiple bright submillimeter galaxies (SMGs). Using deep, high-resolution Karl G. Jansky Very Large Array CO(2-1) observations, we image the molecular gas with a resolution of ?1 kpc just 1.6 Gyr after the big bang. The SMGs GN20.2a and GN20.2b have deconvolved sizes of ?5 kpc × 3 kpc and ?8 kpc × 5 kpc (Gaussian FWHM) in CO(2-1), respectively, and we measure gas surface densities up to ?12,700/1700 × (sin i) (?{sub CO}/0.8) M{sub ?} pc{sup –2} for GN20.2a/GN20.2b in the highest-resolution maps. Dynamical mass estimates allow us to constrain the CO-to-H{sub 2} conversion factor to ?{sub CO} = 1.7 ± 0.8 M{sub ?} (K km s{sup –1} pc{sup 2}){sup –1} for GN20.2a and ?{sub CO}= 1.1±{sup 1.5}{sub 1.1} M{sub ?} (K km s{sup –1} pc{sup 2}){sup –1} for GN20.2b. We measure significant offsets (0.''5-1'') between the CO and optical emission, indicating either dust obscuration on scales of tens of kiloparsecs or that the emission originates from distinct galaxies. CO spectral line energy distributions imply physical conditions comparable to other SMGs and reveal further evidence that GN20.2a and GN20.2b are in different merging stages. We carry out a targeted search for CO emission from the 14 known B-band Lyman break galaxies (LBGs) in the field, tentatively detecting CO in a previously undetected LBG and placing 3? upper limits on the CO luminosities of those that may lie within our bandpass. A blind search for emission-line sources down to a 5? limiting CO luminosity of L{sup ?}{sub CO(2-1)} = 8 x 10{sup 9} K km s{sup –1} pc{sup 2} and covering ?z = 0.0273 (?20 comoving Mpc) produces no other strong contenders associated with the proto-cluster.

  1. Detailed Hydrographic Feature Extraction from High-Resolution LiDAR Data

    SciTech Connect (OSTI)

    Danny L. Anderson

    2012-05-01T23:59:59.000Z

    Detailed hydrographic feature extraction from high-resolution light detection and ranging (LiDAR) data is investigated. Methods for quantitatively evaluating and comparing such extractions are presented, including the use of sinuosity and longitudinal root-mean-square-error (LRMSE). These metrics are then used to quantitatively compare stream networks in two studies. The first study examines the effect of raster cell size on watershed boundaries and stream networks delineated from LiDAR-derived digital elevation models (DEMs). The study confirmed that, with the greatly increased resolution of LiDAR data, smaller cell sizes generally yielded better stream network delineations, based on sinuosity and LRMSE. The second study demonstrates a new method of delineating a stream directly from LiDAR point clouds, without the intermediate step of deriving a DEM. Direct use of LiDAR point clouds could improve efficiency and accuracy of hydrographic feature extractions. The direct delineation method developed herein and termed “mDn”, is an extension of the D8 method that has been used for several decades with gridded raster data. The method divides the region around a starting point into sectors, using the LiDAR data points within each sector to determine an average slope, and selecting the sector with the greatest downward slope to determine the direction of flow. An mDn delineation was compared with a traditional grid-based delineation, using TauDEM, and other readily available, common stream data sets. Although, the TauDEM delineation yielded a sinuosity that more closely matches the reference, the mDn delineation yielded a sinuosity that was higher than either the TauDEM method or the existing published stream delineations. Furthermore, stream delineation using the mDn method yielded the smallest LRMSE.

  2. MAINTAINING HIGH RESOLUTION MASS SPECTROMETRY CAPABILITIES FOR NATIONAL NUCLEAR SECURITY ADMINISTRATION APPLICATIONS

    SciTech Connect (OSTI)

    Wyrick, S.; Cordaro, J.; Reeves, G.; Mcintosh, J.; Mauldin, C.; Tietze, K.; Varble, D.

    2011-06-06T23:59:59.000Z

    The Department of Energy (DOE) National Nuclear Security Administration (NNSA) has a specialized need for analyzing low mass gas species at very high resolutions. The currently preferred analytical method is electromagnetic sector mass spectrometry. This method allows the NNSA Nuclear Security Enterprise (NSE) to resolve species of similar masses down to acceptable minimum detection limits (MDLs). Some examples of these similar masses are helium-4/deuterium and carbon monoxide/nitrogen. Through the 1980s and 1990s, there were two vendors who supplied and supported these instruments. However, with declining procurements and down turns in the economy, the supply of instruments, service and spare parts from these vendors has become less available, and in some cases, nonexistent. The largest NSE user of this capability is the Savannah River Site (SRS), located near Aiken, South Carolina. The Research and Development Engineering (R&DE) Group in the Savannah River National Laboratory (SRNL) investigated the areas of instrument support that were needed to extend the life cycle of these aging instruments. Their conclusions, as to the focus areas of electromagnetic sector mass spectrometers to address, in order of priority, were electronics, software and hardware. Over the past 3-5 years, the R&DE Group has designed state of the art electronics and software that will allow high resolution legacy mass spectrometers, critical to the NNSA mission, to be operated for the foreseeable future. The funding support for this effort has been from several sources, including the SRS Defense Programs, NNSA Readiness Campaign, Pantex Plant and Sandia National Laboratory. To date, electronics systems have been upgraded on one development system at SRNL, two production systems at Pantex and one production system at Sandia National Laboratory. An NSE working group meets periodically to review strategies going forward. The R&DE Group has also applied their work to the electronics for a Thermal Ionization Mass Spectrometer (TIMS) instrument, which applies a similar mass spectrometric technology for resolving high mass isotopes, such as plutonium and uranium. Due to non-compete clauses for DOE, all work has been performed and applied to instruments which are obsolete and are no longer supported by the original vendor.

  3. Temporal implicatures

    E-Print Network [OSTI]

    Thomas, Guillaume (Guillaume Pierre Yves)

    2012-01-01T23:59:59.000Z

    This dissertation proposes a theory of temporal implicatures, and applies it to the study of tense in Mbyá Guaraní. It is composed of two parts. In the first one, I discuss the analyses of temporal implicatures developed ...

  4. Solar Flare Chromospheric Line Emission: Comparison Between IBIS High-resolution Observations and Radiative Hydrodynamic Simulations

    E-Print Network [OSTI]

    da Costa, Fatima Rubio; Petrosian, Vahé; Dalda, Alberto Sainz; Liu, Wei

    2014-01-01T23:59:59.000Z

    Solar flares involve impulsive energy release, which results in enhanced radiation in a broad spectral and at a wide height range. In particular, line emission from the chromosphere (lower atmosphere) can provide critical diagnostics of plasma heating processes. Thus, a direct comparison between high-resolution spectroscopic observations and advanced numerical modeling results can be extremely valuable, but has not been attempted so far. We present in this paper such a self-consistent investigation of an M3.0 flare observed by the Dunn Solar Telescope's (DST) Interferometric Bi-dimensional Spectrometer (IBIS) on 2011 September 24 that we have modeled with the radiative hydrodynamic code RADYN (Carlsson & Stein 1992, 1997; Abbett & Hawley 1999; Allred et al. 2005). We obtained images and spectra of the flaring region with IBIS in H$\\alpha$ 6563 \\AA\\ and Ca II 8542 \\AA, and with the Reuven Ramaty High Energy Solar Spectroscope Imager (RHESSI) in X-rays. The latter was used to infer the non-thermal elect...

  5. High-Resolution Radio Imaging of Gravitational Lensing Candidates in the 1 Jansky BL Lac Sample

    E-Print Network [OSTI]

    T. A. Rector; J. T. Stocke

    2003-02-19T23:59:59.000Z

    While BL Lacertae objects are widely believed to be highly beamed, low-luminosity radio galaxies, many radio-selected BL Lacs have extended radio power levels and optical emission lines that are too luminous to be low-luminosity radio galaxies. Also, Stocke & Rector discovered an excess of MgII absorption systems along BL Lac sightlines compared to quasars, suggesting that gravitational lensing may be another means of creating the BL Lac phenomenon in some cases. We present a search for gravitationally-lensed BL Lacs with deep, high-resolution, two-frequency VLA radio maps of seven lensing candidates from the 1 Jansky BL Lac sample. We find that none of these objects are resolved into an Einstein ring like B 0218+357, nor do any show multiple images of the core. All of the lensing candidates that were resolved show a flat-spectrum core and very unusual, steep-spectrum extended morphology that is incompatible with a multiply lensed system. Thus, while these observations do not rule out microlensing, no macrolensing is observed.

  6. Experimental Investigation and High Resolution Simulation of In-Situ Combustion Processes

    SciTech Connect (OSTI)

    Margot Gerritsen; Tony Kovscek

    2008-04-30T23:59:59.000Z

    This final technical report describes work performed for the project 'Experimental Investigation and High Resolution Numerical Simulator of In-Situ Combustion Processes', DE-FC26-03NT15405. In summary, this work improved our understanding of in-situ combustion (ISC) process physics and oil recovery. This understanding was translated into improved conceptual models and a suite of software algorithms that extended predictive capabilities. We pursued experimental, theoretical, and numerical tasks during the performance period. The specific project objectives were (i) identification, experimentally, of chemical additives/injectants that improve combustion performance and delineation of the physics of improved performance, (ii) establishment of a benchmark one-dimensional, experimental data set for verification of in-situ combustion dynamics computed by simulators, (iii) develop improved numerical methods that can be used to describe in-situ combustion more accurately, and (iv) to lay the underpinnings of a highly efficient, 3D, in-situ combustion simulator using adaptive mesh refinement techniques and parallelization. We believe that project goals were met and exceeded as discussed.

  7. Extended-range grazing-incidence spectrometer for high-resolution extreme ultraviolet measurements on an electron beam ion trap

    SciTech Connect (OSTI)

    Beiersdorfer, P.; Magee, E. W.; Brown, G. V.; Träbert, E.; Widmann, K. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Hell, N. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Dr. Remeis-Sternwarte and ECAP, Universität Erlangen-Nürnberg, 96049 Bamberg (Germany)

    2014-11-15T23:59:59.000Z

    A high-resolution grazing-incidence grating spectrometer has been implemented on the Livermore electron beam ion traps for performing very high-resolution measurements in the soft x-ray and extreme ultraviolet region spanning from below 10 Å to above 300 Å. The instrument operates without an entrance slit and focuses the light emitted by highly charged ions located in the roughly 50 ?m wide electron beam onto a cryogenically cooled back-illuminated charge-coupled device detector. The measured line widths are below 0.025 Å above 100 Å, and the resolving power appears to be limited by the source size and Doppler broadening of the trapped ions. Comparisons with spectra obtained with existing grating spectrometers show an order of magnitude improvement in spectral resolution.

  8. Improvement of the Temporal Contrast of High-Power Laser Pulses

    E-Print Network [OSTI]

    high gain8 pass amplifier ultrafast pulse cleaner 107 preamplifierJ ultrafast pulse cleaner ASE for pulse amplification. In our laser system, we insert the preamplifier and ultrafast pulse cleaner before for optimizing the performance of the ultrafast pulse cleaner. After passing through the pulse cleaner, the high

  9. Analysis of high resolution scatter images from laser damage experiments performed on KDP

    SciTech Connect (OSTI)

    Runkel, M.; Woods, B.; Yan, M. [and others

    1996-01-05T23:59:59.000Z

    Interest in producing high damage threshold KH{sub 2}PO{sub 4} (KDP) and (D{sub x}H{sub 1-x}){sub 2}PO{sub 4} (KD*P, DKDP) for optical switching and frequency conversion applications is being driven by the system requirements for the National Ignition Facility (NIF) at Lawrence Livermore National Lab (LLNL). Historically, the path to achieving higher damage thresholds has been to improve the purity of crystal growth solutions. Application of advanced filtration technology has increased the damage threshold, but gives little insight into the actual mechanisms of laser damage. We have developed a laser scatter diagnostic to better study bulk defects and laser damage mechanisms in KDP and KD*P crystals. This diagnostic consists of a cavity doubled, kilohertz class, Nd:YLF laser (527 nm) and high dynamic range CCD camera which allows imaging of bulk scatter signals. With it, we have performed damage tests at 355 nm on four different {open_quotes}vintages{close_quotes} of KDP crystals, concentrating on crystals produced via fast growth methods. We compare the diagnostic`s resolution to LLNL`s standard damage detection method of 100X darkfield microscopy and discuss its impact on damage threshold determination. We have observed the disappearance of scatter sites upon exposure to subthreshold irradiation. In contrast, we have seen scatterers appear where none previously existed. This includes isolated, large (high signal) sites as well as multiple small scatter sites which appear at fluences above 7 J/cm{sup 2} (fine tracking). However, we have not observed a strong correlation of preexisting scatter sites and laser damage sites. We speculate on the connection between the laser-induced disappearance of scatter sites and the observed increase in damage threshold with laser conditioning.

  10. High-resolution stratigraphic correlations and geochemical analyses, Cretaceous Niobrara formation, northwestern Denver-Julesburg Basin

    SciTech Connect (OSTI)

    Rodriguez, T.E.; Pratt, L.M.

    1985-05-01T23:59:59.000Z

    The middle Santonian-lower Campanian part of the Smoky Hill Member of the Niobrara Formation represents a fourth-order regressive-transgressive cyclotherm. Studies of this interval have improved our understanding of the influence of depositional environments and structural setting on distributions of organic matter in epicontinental marine strata. Geochemical analyses of fresh quarried sections at Lyons and LaPorte, Colorado, show that, in general, C/sub org/ (organic carbon) levels are highest between mid-regression and mid-transgression. Rhythmic fluctuations of C/sub carb/ (carbonate carbon) and C/sub org/ correspond to limestone-marlstone bedding couplets at a scale of 15-20 cm (6-8 in.). Pronounced lateral variations between Lyons and LaPorte exist in C/sub org/, HI (pyrolytic hydrogen index), sediment accumulation rates, and T/sub max/ (temperature of maximum pyrolytic yield). Comparisons of geochemical averages at Lyons and LaPorte indicate an elevated thermal maturity at Lyons and depositional conditions more favorable for preservation of marine organic matter at LaPorte. In both sections, C/sub org/ and C/sub carb/ show strong negative correlations, possibly reflecting cyclic climatic controls on the development of bedding couplets. High-resolution stratigraphic correlations of 100.000-year or smaller intervals between Boulder and Owl Canyon, Colorado, based on wide-spread bentonites and bedding couplets, reveal a paleostructural high near Lyons. Shallow-water conditions and increased turbulence over this high are reflected in sediment accumulation rates only 60% of those at LaPorte. Increased amounts and hydrogen richness of organic matter at LaPorte may reflect a deeper water, more quiescent depositional setting.

  11. Sub-population analysis based on temporal features of high content images

    E-Print Network [OSTI]

    Rajapakse, Jagath

    Background: High content screening techniques are increasingly used to understand the regulation and progression of cell motility. The demand of new platforms, coupled with availability of terabytes of data has challenged ...

  12. Novel Large Area High Resolution Neutron Detector for the Spallation Neutron Source

    SciTech Connect (OSTI)

    Lacy, Jeffrey L

    2009-05-22T23:59:59.000Z

    Neutron scattering is a powerful technique that is critically important for materials science and structural biology applications. The knowledge gained from past developments has resulted in far-reaching advances in engineering, pharmaceutical and biotechnology industries, to name a few. New facilities for neutron generation at much higher flux, such as the SNS at Oak Ridge, TN, will greatly enhance the capabilities of neutron scattering, with benefits that extend to many fields and include, for example, development of improved drug therapies and materials that are stronger, longer-lasting, and more impact-resistant. In order to fully realize this enhanced potential, however, higher neutron rates must be met with improved detection capabilities, particularly higher count rate capability in large size detectors, while maintaining practicality. We have developed a neutron detector with the technical and economic advantages to accomplish this goal. This new detector has a large sensitive area, offers 3D spatial resolution, high sensitivity and high count rate capability, and it is economical and practical to produce. The proposed detector technology is based on B-10 thin film conversion of neutrons in long straw-like gas detectors. A stack of many such detectors, each 1 meter in length, and 4 mm in diameter, has a stopping power that exceeds that of He-3 gas, contained at practical pressures within an area detector. With simple electronic readout methods, straw detector arrays can provide spatial resolution of 4 mm FWHM or better, and since an array detector of such form consists of several thousand individual elements per square meter, count rates in a 1 m^2 detector can reach 2?10^7 cps. Moreover, each individual event can be timetagged with a time resolution of less than 0.1 ?sec, allowing accurate identification of neutron energy by time of flight. Considering basic elemental cost, this novel neutron imaging detector can be commercially produced economically, probably at a small fraction of the cost of He-3 detectors. In addition to neutron scattering science, the fully developed base technology can be used as a rugged, low-cost neutron detector in area monitoring and surveying. Radiation monitors are used in a number of other settings for occupational and environmental radiation safety. Such a detector can also be used in environmental monitoring and remote nuclear power plant monitoring. For example, the Department of Energy could use it to characterize nuclear waste dumps, coordinate clean-up efforts, and assess the radioactive contaminants in the air and water. Radiation monitors can be used to monitor the age and component breakdown of nuclear warheads and to distinguish between weapons and reactor grade plutonium. The UN's International Atomic Energy Agency (IAEA) uses radiation monitors for treaty verification, remote monitoring, and enforcing the non-proliferation of nuclear weapons. As part of treaty verification, monitors can be used to certify the contents of containers during inspections. They could be used for portal monitoring to secure border checkpoints, sea ports, air cargo centers, public parks, sporting venues, and key government buildings. Currently, only 2% of all sea cargo shipped is inspected for radiation sources. In addition, merely the presence of radiation is detected and nothing is known about the radioactive source until further testing. The utilization of radiation monitors with neutron sensitivity and capability of operation in hostile port environments would increase the capacity and effectiveness of the radioactive scanning processes.

  13. High resolution seismic survey of the Hanna, Wyoming underground coal gasification area

    SciTech Connect (OSTI)

    Not Available

    1983-08-01T23:59:59.000Z

    In June 1983 a high resolution seismic survey was conducted at the Department of Energy, Laramie Energy Technology Center's underground coal gasification test site near Hanna, Wyoming. The objectives of the survey were to locate and characterize underground burn zones and to identify shallow geologic faults at the test site. Seismic data acquisition and processing parameters were based upon prior work in the area, and were specifically designed to emphasize reflections at the shallow, 61 to 91 meter (200 to 300 ft) depths of interest. Data were obtained on two north-south lines along the test site boundary in addition to a three-dimensional grid over the Hanna IV experiment area. Processing included time varying filters, deconvolution, trace composition, and three-dimensional areal stacking of the data in order to identify burn zone anomalies. Anomalies were discernable resulting from the rubble-collapse void above the burn zones in the vicinity of the injection wells at the Hanna IV experiment area. The fault studies disclosed faults at the Hanna IV experiment area which may be responsible for the unexpected problems experienced in the early in-site gasification tests. For the test site the fault system was found to be a generally arcuate east-west trending graben complex with numerous antithetic faults. 15 references, 33 figures, 6 tables.

  14. High-Resolution CT and Angiographic Evaluation of NexStent Wall Adaptation

    SciTech Connect (OSTI)

    Nemes, Balazs, E-mail: nembal@freemail.hu; Lukacs, Levente; Balazs, Gyoergy [Semmelweis University, Cardiovascular Center (Hungary); Dosa, Edit; Berczi, Viktor [Semmelweis University, Department of Cardiovascular Surgery (Hungary); Huettl, Kalman [Semmelweis University, Cardiovascular Center (Hungary)

    2009-05-15T23:59:59.000Z

    Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 {+-} 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic and computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 {+-} 8% before the procedure to 15.7 {+-} 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.

  15. High-resolution method applied to premixing phase of steam explosion

    SciTech Connect (OSTI)

    Leskovar, M.; Mavko, B.; Marn, J. [Univ. of Maribor (Slovenia)

    1997-12-01T23:59:59.000Z

    This paper describes the improved version of the general two-dimensional, multiphase flow code ESE. The ESE code has been developed to model the mixing process and interaction of molten core debris with water. In case of a steam explosion, a trigger may produce locally enhanced heat transfer and pressurization and may evolve into a shock propagating through the coarse mixture. The propagation phase of the interaction is not modeled by the code; however, the ESE provides for initial condition evolution in time. The indication of the amount of well-mixed melt at the time of the trigger occurrence can be deduced based on the code`s results. The objective of this work is to present the advantages of the high-resolution method applied to a particular set of partial differential equations and to incorporate these advantages into a code that was conceived using less traveled paths, namely, ensemble averaging and use of available data in probabilistic density functions describing momentum and energy cofluctuation tensors.

  16. Solar coronal magnetic field topology inferred from high resolution optical and x-ray movies

    SciTech Connect (OSTI)

    Tarbell, T.; Frank, Z.; Hurlburt, N.; Morrison, M.; Shine, R.; Title, A.; Acton, L.

    1993-01-01T23:59:59.000Z

    The authors are using high resolution digital movies of solar active regions in optical and X-ray wavelengths to study solar flares and other transients. The optical movies were collected at the Swedish Solar Observatory on La Palma using the Lockheed tunable filtergraph system, in May-July, 1992. They include longitudinal and transverse magnetograms, H-alpha Doppler and intensity images at many wavelengths, Ca K, Na D, and white light images. Simultaneous X-ray images from Yohkoh are available much of the time. Several ways to establish the connectivity of some coronal magnetic field lines are being explored. Some of the clues available are: magnetic footpoint polarities and transverse field direction; H-alpha fibrils and loops seen in several wavelengths; proper motion and Dopper shifts of blobs moving along field lines; footprint brightening in micro-flares; spreading of flare ribbons during gradual phases of flares; X-ray morphology and correlations with H-alpha; and draining of flare loops. Examples of each of these will be shown on video.

  17. Characterization of Monoenergetic Neutron Reference Fields with a High Resolution Diamond Detector

    E-Print Network [OSTI]

    Zimbal, A; Nolte, R; Schuhmacher, H

    2009-01-01T23:59:59.000Z

    A novel radiation detector based on an artificial single crystal diamond was used to characterize in detail the energy distribution of neutron reference fields at the Physikalisch-Technische Bundesanstalt (PTB) and their contamination with charged particles. The monoenergetic reference fields at PTB in the neutron energy range from 1.5 MeV up to 19 MeV are generated by proton and deuteron beams impinging on solid and gas targets of tritium and deuterium. The energy of the incoming particles and the variation of the angle under which the measurement is performed produce monoenergetic reference fields with different mean energies and line shapes. In this paper we present high resolution neutron spectrometry measurements of different monoenergetic reference fields. The results are compared with calculated spectra taking into account the actual target parameters. Line structures in the order of 80 keV for a neutron energy of 9 MeV were resolved. The shift of the mean energy and the increasing of the width of the ...

  18. High resolution n = 3 to n = 2 spectra of neon-like silver

    SciTech Connect (OSTI)

    Beiersdorfer, P.; Bitter, M.; von Goeler, S.; Cohen, S.; Hill, K.W.; Timberlake, J.; Walling, R.S.; Chen, M.H.; Hagelstein, P.L.; Scofield, J.H.

    1986-04-01T23:59:59.000Z

    Spectra of the n = 3 to n = 2 transitions in neon-like silver emitted from the Princeton Large Torus have been recorded with a high-resolution Bragg-crystal spectrometer. The measurements cover the wavelength region 3.3 to 4.1 A and include the forbidden 3p ..-->.. 2p electric quadrupole lines. Transitions in the adjacent sodium-like, and aluminum-like charge states of silver have also been observed and identified. The Ly-..cap alpha.. spectra of hydrogen-like argon and iron, the K..cap alpha.. spectra of helium-like argon, potassium, manganese, and iron, and the K..beta.. spectrum of helium-like argon fall in the same wavelength region in first or second order and have been measured concurrently. These spectra provide a coherent set of wavelength reference data obtained with the same spectrometer and from the same tokamak. This set is used as a basis to compare wavelength predictions for one- and two-electron systems to each other and to determine the transition energies of the silver lines with great accuracy.

  19. Magnetic lens apparatus for use in high-resolution scanning electron microscopes and lithographic processes

    DOE Patents [OSTI]

    Crewe, Albert V. (Dune Acres, IN)

    2000-01-01T23:59:59.000Z

    Disclosed are lens apparatus in which a beam of charged particlesis brought to a focus by means of a magnetic field, the lens being situated behind the target position. In illustrative embodiments, a lens apparatus is employed in a scanning electron microscopeas the sole lens for high-resolution focusing of an electron beam, and in particular, an electron beam having an accelerating voltage of from about 10 to about 30,000 V. In one embodiment, the lens apparatus comprises an electrically-conducting coil arranged around the axis of the beam and a magnetic pole piece extending along the axis of the beam at least within the space surrounded by the coil. In other embodiments, the lens apparatus comprises a magnetic dipole or virtual magnetic monopole fabricated from a variety of materials, including permanent magnets, superconducting coils, and magnetizable spheres and needles contained within an energy-conducting coil. Multiple-array lens apparatus are also disclosed for simultaneous and/or consecutive imaging of multiple images on single or multiple specimens. The invention further provides apparatus, methods, and devices useful in focusing charged particle beams for lithographic processes.

  20. High resolution optical spectroscopy of an LBV-candidate inside the CygOB2 association

    E-Print Network [OSTI]

    Klochkova, V G

    2004-01-01T23:59:59.000Z

    For the first time, we obtained the high-resolution (R=15000 and 60000) optical spectra for the extremely luminous star No.12, associated with the IR-source IRAS20308+4104, a member of the CygOB2 association. We have found about 200 spectral features in range 4552-7939AA, including the interstellar NaI, KI lines and numerous DIBs, which are the strongest absorption lines in the spectrum, along with the HeI, CII, and SiII lines. A two-dimensional spectral classification indicates that the spectral type is B5+/-0.5 Ia+. Our analysis of the Vr data shows the presence of a Vr gradient in the stellar atmosphere, caused by the infall of matter onto the star. The strong Halpha emission displays broad Thompson wings and time-variable core absorption, providing evidence that the stellar wind is inhomogeneous, and a slightly blue-shifted PCyg type absorption profile. We concluded that the wind is variable in time.

  1. A High Resolution Hydrodynamic Model of Puget Sound to Support Nearshore Restoration Feasibility Analysis and Design

    SciTech Connect (OSTI)

    Khangaonkar, Tarang; Yang, Zhaoqing

    2011-01-01T23:59:59.000Z

    Estuarine and coastal hydrodynamic processes are sometimes neglected in the design and planning of nearshore restoration actions. Despite best intentions, efforts to restore nearshore habitats can result in poor outcomes if circulation and transport which also affect freshwater-saltwater interactions are not properly addressed. Limitations due to current land use can lead to selection of sub-optimal restoration alternatives that may result in undesirable consequences, such as flooding, deterioration of water quality, and erosion, requiring immediate remedies and costly repairs. Uncertainty with achieving restoration goals, such as recovery of tidal exchange, supply of sediment and nutrients, and establishment of fish migration pathways, may be minimized by using numerical models designed for application to the nearshore environment. A high resolution circulation and transport model of the Puget Sound, in the state of Washington, was developed to assist with nearshore habitat restoration design and analysis, and to answer the question “can we achieve beneficial restoration outcomes at small local scale, as well as at a large estuary-wide scale?” The Puget Sound model is based on an unstructured grid framework to define the complex Puget Sound shoreline using a finite volume coastal ocean model (FVCOM). The capability of the model for simulating the important nearshore processes, such as circulation in complex multiple tidal channels, wetting and drying of tide flats, and water quality and sediment transport as part of restoration feasibility, are illustrated through examples of restoration projects in Puget Sound.

  2. Applications of High Resolution Laser Induced Breakdown Spectroscopy for Environmental and Biological Samples

    SciTech Connect (OSTI)

    Martin, Madhavi Z [ORNL; Labbe, Nicole [ORNL; Wagner, Rebekah J. [Pennsylvania State University, University Park, PA

    2013-01-01T23:59:59.000Z

    This chapter details the application of LIBS in a number of environmental areas of research such as carbon sequestration and climate change. LIBS has also been shown to be useful in other high resolution environmental applications for example, elemental mapping and detection of metals in plant materials. LIBS has also been used in phytoremediation applications. Other biological research involves a detailed understanding of wood chemistry response to precipitation variations and also to forest fires. A cross-section of Mountain pine (pinceae Pinus pungen Lamb.) was scanned using a translational stage to determine the differences in the chemical features both before and after a fire event. Consequently, by monitoring the elemental composition pattern of a tree and by looking for abrupt changes, one can reconstruct the disturbance history of a tree and a forest. Lastly we have shown that multivariate analysis of the LIBS data is necessary to standardize the analysis and correlate to other standard laboratory techniques. LIBS along with multivariate statistical analysis makes it a very powerful technology that can be transferred from laboratory to field applications with ease.

  3. High-Resolution Desorption Electrospray Ionization Mass Spectrometry for Chemical Characterization of Organic Aerosols

    SciTech Connect (OSTI)

    Laskin, Julia; Laskin, Alexander; Roach, Patrick J.; Slysz, Gordon W.; Anderson, Gordon A.; Nizkorodov, Serguei; Bones, David L.; Nguyen, Lucas

    2010-03-01T23:59:59.000Z

    Characterization of the chemical composition and chemical transformations of secondary organic aerosol (SOA) is both a major challenge and the area of greatest uncertainty in current aerosol research. This study presents the first application of desorption electrospray ionization combined with high-resolution mass spectrometry (DESI-MS) for detailed chemical characterization and studies of chemical aging of OA collected on Teflon substrates. DESI-MS offers unique advantages both for detailed characterization of chemically labile components in OA that cannot be detected using more traditional electrospray ionization mass spectrometry (ESI-MS) and for studying chemical aging of OA. DESI-MS enables rapid characterization of OA samples collected on substrates by eliminating the sample preparation stage. In addition, it enables detection and structural characterization of chemically labile molecules in OA samples by minimizing the residence time of analyte in the solvent. SOA produced by the ozonolysis of limonene (LSOA) was allowed to react with gaseous ammonia. Chemical aging resulted in measurable changes in the optical properties of LSOA observed using UV- visible spectroscopy. DESI-MS combined with tandem mass spectrometry experiments (MS/MS) enabled identification of species in aged LSOA responsible for absorption of the visible light. Detailed analysis of the experimental data allowed us to identify chemical changes induced by reactions of LSOA constituents with ammonia and distinguish between different mechanisms of chemical aging.

  4. Doppler tomography of the Little Homunculus: High resolution spectra of [Fe II] 16435 around Eta Carinae

    E-Print Network [OSTI]

    Nathan Smith

    2004-12-21T23:59:59.000Z

    High-resolution spectra of [Fe II] 16435 around eta Carinae provide powerful diagnostics of the geometry and kinematics of the ``Little Homunculus'' (LH) growing inside the larger Homunculus nebula. The LH expansion is not perfectly homologous: while low-latitudes are consistent with linear expansion since 1910, the polar caps imply ejection dates around 1920--1930. However, the expansion speed of the LH is slower than the post-eruption wind, so the star's powerful wind may accelerate it. With an initial ejection speed of 200 km/s in 1890, the LH would have been accelerated to its present speed if the mass is roughly 0.1 Msun. This agrees with an independent estimate of the LH mass based on its density and volume. In any case, an ejection after 1930 is ruled out. Using the LH as a probe of the 1890 event, then, it is evident that its most basic physical parameters (total mass and kinetic energy; 0.1 Msun and 10^46.9 ergs, respectively) are orders of magnitude less than during the giant eruption in the 1840s. Thus, the ultimate energy sources were different for these two events -- yet their ejecta have the same bipolar geometry. This clue may point toward a collimation mechanism separate from the underlying causes of the outbursts.

  5. Hubble space telescope high-resolution imaging of Kepler small and cool exoplanet host stars

    SciTech Connect (OSTI)

    Gilliland, Ronald L.; Cartier, Kimberly M. S.; Wright, Jason T. [Department of Astronomy and Astrophysics, and Center for Exoplanets and Habitable Worlds, The Pennsylvania State University, 525 Davey Lab, University Park, PA 16802 (United States); Adams, Elisabeth R. [Planetary Science Institute, 1700 East Fort Lowell, Suite 106, Tucson, AZ 85719 (United States); Ciardi, David R. [NASA Exoplanet Science Institute/Caltech, Pasadena, CA 91125 (United States); Kalas, Paul, E-mail: gillil@stsci.edu [Astronomy Department, University of California, Berkeley, CA 94720 (United States)

    2015-01-01T23:59:59.000Z

    High-resolution imaging is an important tool for follow-up study of exoplanet candidates found via transit detection with the Kepler mission. We discuss here Hubble Space Telescope imaging with the WFC3 of 23 stars that host particularly interesting Kepler planet candidates based on their small size and cool equilibrium temperature estimates. Results include detections, exclusion of background stars that could be a source of false positives for the transits, and detection of physically associated companions in a number of cases providing dilution measures necessary for planet parameter refinement. For six Kepler objects of interest, we find that there is ambiguity regarding which star hosts the transiting planet(s), with potentially strong implications for planetary characteristics. Our sample is evenly distributed in G, K, and M spectral types. Albeit with a small sample size, we find that physically associated binaries are more common than expected at each spectral type, reaching a factor of 10 frequency excess in M. We document the program detection sensitivities, detections, and deliverables to the Kepler follow-up program archive.

  6. The High Time Resolution Universe Survey VI: An Artificial Neural Network and Timing of 75 Pulsars

    E-Print Network [OSTI]

    Bates, S D; Barsdell, B R; Bhat, N D R; Burgay, M; Burke-Spolaor, S; Champion, D J; Coster, P; D'Amico, N; Jameson, A; Johnston, S; Keith, M J; Kramer, M; Levin, L; Lyne, A; Milia, S; Ng, C; Nietner, C; Possenti, A; Stappers, B; Thornton, D; van Straten, W

    2012-01-01T23:59:59.000Z

    We present 75 pulsars discovered in the mid-latitude portion of the High Time Resolution Universe survey, 54 of which have full timing solutions. All the pulsars have spin periods greater than 100 ms, and none of those with timing solutions are in binaries. Two display particularly interesting behaviour; PSR J1054-5944 is found to be an intermittent pulsar, and PSR J1809-0119 has glitched twice since its discovery. In the second half of the paper we discuss the development and application of an artificial neural network in the data-processing pipeline for the survey. We discuss the tests that were used to generate scores and find that our neural network was able to reject over 99% of the candidates produced in the data processing, and able to blindly detect 85% of pulsars. We suggest that improvements to the accuracy should be possible if further care is taken when training an artificial neural network; for example ensuring that a representative sample of the pulsar population is used during the training proc...

  7. High-resolution thermal expansion measurements under helium-gas pressure

    SciTech Connect (OSTI)

    Manna, Rudra Sekhar; Wolf, Bernd; Souza, Mariano de; Lang, Michael [Physics Institute, Goethe University Frankfurt(M), SFB/TR49, D-60438 Frankfurt am Main (Germany)

    2012-08-15T23:59:59.000Z

    We report on the realization of a capacitive dilatometer, designed for high-resolution measurements of length changes of a material for temperatures 1.4 K Less-Than-Or-Slanted-Equal-To T Less-Than-Or-Slanted-Equal-To 300 K and hydrostatic pressure P Less-Than-Or-Slanted-Equal-To 250 MPa. Helium ({sup 4}He) is used as a pressure-transmitting medium, ensuring hydrostatic-pressure conditions. Special emphasis has been given to guarantee, to a good approximation, constant-pressure conditions during temperature sweeps. The performance of the dilatometer is demonstrated by measurements of the coefficient of thermal expansion at pressures P Asymptotically-Equal-To 0.1 MPa (ambient pressure) and 104 MPa on a single crystal of azurite, Cu{sub 3}(CO{sub 3}){sub 2}(OH){sub 2}, a quasi-one-dimensional spin S = 1/2 Heisenberg antiferromagnet. The results indicate a strong effect of pressure on the magnetic interactions in this system.

  8. High-resolution spectroscopy of the R Coronae Borealis Star V Coronae Australis

    E-Print Network [OSTI]

    N. Kameswara Rao; David L. Lambert

    2007-10-26T23:59:59.000Z

    Optical high-resolution spectra of the R Coronae Borealis star V CrA at light maximum and during minimum light arediscussed. Abundance analysis confirms previous results showing that V CrA has the composition of the small subclass of R Coronae Borealis (RCB) stars know as `minority' RCBs, i.e., the Si/Fe and S/Fe ratios are 100 times their solar values. A notable novel result for RCBs is the detection of the 1-0 Swan system $^{12}$C$^{13}$C bandhead indicating that $^{13}$C is abundant: spectrum synthesis shows that $^{12}$C/$^{13}$C is about 3 to 4. Absorption line profiles are variable at maximum light with some lines showing evidence of splitting by about 10 km s$^{-1}$. A spectrum obtained as the star was recovering from a deep minimum shows the presence of cool C$_2$ molecules with a rotational temperature of about 1200K, a temperature suggestive of gas in which carbon is condensing into soot. The presence of rapidly outflowing gas is shown by blue-shifted absorption components of the Na {\\sc i} D and K {\\sc i} 7698 \\AA resonance lines.

  9. SOFIA/EXES Observations of Water Absorption in the Protostar AFGL 2591 at High Spectral Resolution

    E-Print Network [OSTI]

    Indriolo, Nick; DeWitt, C N; Richter, M J; Boogert, A C A; Harper, G M; Jaffe, D T; Kulas, K R; McKelvey, M E; Ryde, N; Vacca, W

    2015-01-01T23:59:59.000Z

    We present high spectral resolution (~3 km/s) observations of the nu_2 ro-vibrational band of H2O in the 6.086--6.135 micron range toward the massive protostar AFGL 2591 using the Echelon-Cross-Echelle Spectrograph (EXES) on the Stratospheric Observatory for Infrared Astronomy (SOFIA). Ten absorption features are detected in total, with seven caused by transitions in the nu_2 band of H2O, two by transitions in the first vibrationally excited nu_2 band of H2O, and one by a transition in the nu_2 band of H2{18}O. Among the detected transitions is the nu_2 1(1,1)--0(0,0) line which probes the lowest lying rotational level of para-H2O. The stronger transitions appear to be optically thick, but reach maximum absorption at a depth of about 25%, suggesting that the background source is only partially covered by the absorbing gas, or that the absorption arises within the 6 micron emitting photosphere. Assuming a covering fraction of 25%, the H2O column density and rotational temperature that best fit the observed abs...

  10. A high-throughput, high-resolution spectrometer for mapping the heliopause and 3-D Solar Wind using He+ 30.4nm

    E-Print Network [OSTI]

    California at Berkeley, University of

    A high-throughput, high-resolution spectrometer for mapping the heliopause and 3-D Solar Wind using Entrance slit farm with ~ 1000 slits Photon counting imager Concave grating used near normal incidence >> Need a higher throughput diffuse EUV spectrometer solar wind respond to coronal

  11. High-Resolution Modeling to Assess Tropical Cyclone Activity in Future Climate Regimes

    SciTech Connect (OSTI)

    Lackmann, Gary

    2013-06-10T23:59:59.000Z

    Applied research is proposed with the following objectives: (i) to determine the most likely level of tropical cyclone intensity and frequency in future climate regimes, (ii) to provide a quantitative measure of uncertainty in these predictions, and (iii) to improve understanding of the linkage between tropical cyclones and the planetary-scale circulation. Current mesoscale weather forecasting models, such as the Weather Research and Forecasting (WRF) model, are capable of simulating the full intensity of tropical cyclones (TC) with realistic structures. However, in order to accurately represent both the primary and secondary circulations in these systems, model simulations must be configured with sufficient resolution to explicitly represent convection (omitting the convective parameterization scheme). Most previous numerical studies of TC activity at seasonal and longer time scales have not utilized such explicit convection (EC) model runs. Here, we propose to employ the moving nest capability of WRF to optimally represent TC activity on a seasonal scale using a downscaling approach. The statistical results of a suite of these high-resolution TC simulations will yield a realistic representation of TC intensity on a seasonal basis, while at the same time allowing analysis of the feedback that TCs exert on the larger-scale climate system. Experiments will be driven with analyzed lateral boundary conditions for several recent Atlantic seasons, spanning a range of activity levels and TC track patterns. Results of the ensemble of WRF simulations will then be compared to analyzed TC data in order to determine the extent to which this modeling setup can reproduce recent levels of TC activity. Next, the boundary conditions (sea-surface temperature, tropopause height, and thermal/moisture profiles) from the recent seasons will be altered in a manner consistent with various future GCM/RCM scenarios, but that preserves the large-scale shear and incipient disturbance activity. This will allow (i) a direct comparison of future TC activity that could be expected for an active or inactive season in an altered climate regime, and (ii) a measure of the level of uncertainty and variability in TC activity resulting from different carbon emission scenarios.

  12. Spectral, temporal and temperature features of the nonlinear response of high-temperature superconductors in transient nonlinear spectroscopy

    SciTech Connect (OSTI)

    Bobyrev, Yu V; Petnikova, V M; Rudenko, K V; Shuvalov, Vladimir V [International Laser Center, M. V. Lomonosov Moscow State University, Moscow (Russian Federation)

    2006-10-31T23:59:59.000Z

    It is shown that basic properties of the nonlinear response of high-temperature superconductors (HTSCs) observed in femtosecond and picosecond pump-probe experiments at high and low pump levels in various variants of the pump-probe spectroscopy, including one- and two-photon excited-state probing, can be interpreted by using two assumptions. The spectral and temperature properties of the HTSC response at low pump levels can be explained taking into account the contributions from interband electronic transitions to the dielectric constant. At the same time, drastic variations in the HTSC response kinetics (temporal features) observed at high pump levels (for a typical pump pulse energy of {approx}10{sup -7} J in a focal spot of diameter 150 {mu}m) can be explained by assuming the existence of a 'frozen' (metastable) energy gap in the electronic spectrum of a HTSC. In this case, all the conditions required for the interpretation of a drastic decrease in the relaxation rate of a nonlinear response (degeneracy) are realised due to the specific distribution of the electronic state density immediately after the formation of the energy gap in the electronic spectrum of the HTSC. (review)

  13. Phys. Med. Biol. 43 (1998) 10011013. Printed in the UK PII: S0031-9155(98)90627-3 High-resolution 3D Bayesian image reconstruction using

    E-Print Network [OSTI]

    Leahy, Richard M.

    1998-01-01T23:59:59.000Z

    -resolution 3D Bayesian image reconstruction using the microPET small-animal scanner Jinyi Qi, Richard M Leahy of high-resolution 3D images from the microPET small-animal scanner. Resolution recovery is achieved 2 mm when using an analytic 3D reprojection (3DRP) method with a ramp filter. These results also

  14. Current Theoretical Models and Future High Resolution Solar Observations: Preparing for ATST ASP Conference Series, Vol. ???, 2002

    E-Print Network [OSTI]

    Observatory, China derived with a solar scintillometer (Seykora 1992) and a Solar Differential Image MotionCurrent Theoretical Models and Future High Resolution Solar Observations: Preparing for ATST ASP-Site Observatory Carsten Denker New Jersey Institute of Technology, Center for Solar Research 323 Martin Luther

  15. HIGH-RESOLUTION INFRARED IMAGING AND SPECTROSCOPY OF THE Z CANIS MAJORIS SYSTEM DURING QUIESCENCE AND OUTBURST

    SciTech Connect (OSTI)

    Hinkley, Sasha; Hillenbrand, Lynne; Crepp, Justin R. [Department of Astronomy, California Institute of Technology, 1200 E. California Blvd, MC 249-17, Pasadena, CA 91125 (United States); Oppenheimer, Ben R.; Zimmerman, Neil; Brenner, Douglas [Astrophysics Department, American Museum of Natural History, Central Park West at 79th Street, New York, NY 10024 (United States); Rice, Emily L. [Department of Engineering Science and Physics, College of Staten Island, City University of New York, 2800 Victory Bvld, Staten Island, NY 10314 (United States); Pueyo, Laurent [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Vasisht, Gautam; Roberts, Jennifer E.; Roberts, Lewis C. Jr.; Burruss, Rick; Wallace, J. Kent; Cady, Eric; Zhai, Chengxing [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Dr., Pasadena, CA 91109 (United States); Kraus, Adam L. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA, 02138 (United States); Ireland, Michael J. [Department of Physics and Astronomy, Macquarie University, New South Wales, NSW 2109 (Australia); Beichman, Charles [NASA Exoplanet Science Institute, California Institute of Technology, Pasadena, CA 91125 (United States); Dekany, Richard [Caltech Optical Observatories, California Institute of Technology, Pasadena, CA 91125 (United States); Parry, Ian R. [Institute of Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom); and others

    2013-01-20T23:59:59.000Z

    We present adaptive optics photometry and spectra in the JHKL bands along with high spectral resolution K-band spectroscopy for each component of the Z Canis Majoris system. Our high angular resolution photometry of this very young ({approx}<1 Myr) binary, comprised of an FU Ori object and a Herbig Ae/Be star, was gathered shortly after the 2008 outburst while our high-resolution spectroscopy was gathered during a quiescent phase. Our photometry conclusively determines that the outburst was due solely to the embedded Herbig Ae/Be member, supporting results from earlier works, and that the optically visible FU Ori component decreased slightly ({approx}30%) in luminosity during the same period, consistent with previous works on the variability of FU Ori type systems. Further, our high-resolution K-band spectra definitively demonstrate that the 2.294 {mu}m CO absorption feature seen in composite spectra of the system is due solely to the FU Ori component, while a prominent CO emission feature at the same wavelength, long suspected to be associated with the innermost regions of a circumstellar accretion disk, can be assigned to the Herbig Ae/Be member. These findings clarify previous analyses of the origin of the CO emission in this complex system.

  16. High-Resolution Monitoring of Internal Layers Over the Greenland Ice Sheet P. Kanagaratnam, S.P. Gogineni

    E-Print Network [OSTI]

    Kansas, University of

    High-Resolution Monitoring of Internal Layers Over the Greenland Ice Sheet P. Kanagaratnam, S ice plays an important role in the rise of the Earth's sea level. A key variable in assessing the mass balance of an ice sheet is accumulation rate, which is currently determined from ice cores and pits

  17. Central South Pacific thermocline water circulation from a high-resolution ocean model validated against satellite data

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Central South Pacific thermocline water circulation from a high-resolution ocean model validated. Introduction [2] Most South Pacific Ocean studies have been focused on its western or eastern part, leaving 12 January 2009; accepted 28 January 2009; published 13 May 2009. [1] The oceanic circulation

  18. High-Energy-Resolution Inelastic Electron and Proton Scattering and the Multiphonon Nature of Mixed-Symmetry 2

    E-Print Network [OSTI]

    Ponomarev, Vladimir

    , University of Cape Town, Rondebosch 7700, South Africa 3 School of Physics, University of the Witwatersrand, Johannesburg 2050, South Africa 4 iThemba LABS, PO Box 722, Somerset West 7129, South Africa 5 Institut fuHigh-Energy-Resolution Inelastic Electron and Proton Scattering and the Multiphonon Nature of Mixed

  19. Automated landslide mapping using spectral analysis and high-resolution topographic data: Puget Sound lowlands, Washington, and Portland Hills, Oregon

    E-Print Network [OSTI]

    Perron, Taylor

    Automated landslide mapping using spectral analysis and high-resolution topographic data: Puget Landslide map LiDAR Tualatin Puget Wavelet Landslide inventory maps are necessary for assessing landslide of spectral analysis that utilize LiDAR-derived digital elevation models of the Puget Sound lowlands

  20. High-resolution reservoir characterization by an acoustic impedance inversion of a Tertiary deltaic clinoform system in the North Sea

    E-Print Network [OSTI]

    van Vliet, Lucas J.

    High-resolution reservoir characterization by an acoustic impedance inversion of a Tertiary deltaic a low level of parameterization embedded in a geologic framework and is computationally fast. The second in the geologic settings of the res- ervoir; however, there is no explicit geologic significance and the method

  1. High-resolution clinoform characterization by 2-D model-driven seismic Bayesian inversion Daria Tetyukhina*1

    E-Print Network [OSTI]

    van Vliet, Lucas J.

    High-resolution clinoform characterization by 2-D model-driven seismic Bayesian inversion Daria Summary Many important details of potential subsurface reservoirs that we wish to characterize are only propose an automated procedure that adjusts the parameters of a two-dimensional geological model

  2. A HIGH RESOLUTION, STICTIONLESS, CMOS COMPATIBLE SOI ACCELEROMETER WITH A LOW NOISE, LOW POWER, 0.25M CMOS INTERFACE

    E-Print Network [OSTI]

    Ayazi, Farrokh

    interfaced with a high resolution, low noise and low power switched-capacitor integrated circuit (IC, vibration analysis, GPS-augmented navigation, and spacecraft guidance/stabilization [2]. The use of thick equivalent acceleration (BNEA) is expressed by: MQ Tk M TDk BNEA BB 044 == Hz sm 2 / (5) The air

  3. Structural characterization of water-bearing silicate and aluminosilicate glasses by high-resolution solid-state NMR

    E-Print Network [OSTI]

    Boyer, Edmond

    Structural characterization of water-bearing silicate and aluminosilicate glasses by high-resolution solid-state NMR techniques have been applied to hydrous silicate and aluminosilicate glasses: simple as to completely exclude any of the different previously proposed models for water incorporation in silicate

  4. High-resolution modeling of the western North American power system demonstrates low-cost and low-carbon futures

    E-Print Network [OSTI]

    Kammen, Daniel M.

    electric power system models primarily address either day-to-day operation or long-term capacity planningHigh-resolution modeling of the western North American power system demonstrates low-cost and low greenhouse gas emissions. Exploiting intermittent renewable energy resources demands power system planning

  5. A short timescale for changing oxygen fugacity in the solar nebula revealed by high-resolution 26

    E-Print Network [OSTI]

    Manning, Craig

    A short timescale for changing oxygen fugacity in the solar nebula revealed by high-resolution 26 of Mineralogy, Natural History Museum, Cromwell Road London, SW7 7BD, UK Received 4 April 2005; received Abstract Most rocky objects in the solar system, including the primitive chondrites and the terrestrial

  6. Ribosomal Proteins S5 and L6: High-resolution Crystal Structures and Roles in Protein Synthesis and

    E-Print Network [OSTI]

    Ramakrishnan, Venki

    Ribosomal Proteins S5 and L6: High-resolution Crystal Structures and Roles in Protein Synthesis proteins and characterize these mutations. The S5 protein, from the small ribosomal unit, is associated propose that the C-terminal half of S5, which contains the accuracy mutations, organizes RNA structures

  7. High-resolution solid-state NMR of anisotropically mobile molecules under very low-power 1

    E-Print Network [OSTI]

    Hong, Mei

    High-resolution solid-state NMR of anisotropically mobile molecules under very low-power 1 H Revised 13 May 2009 Available online 21 May 2009 Keywords: Low-power decoupling Lipid membranes Solid such as WALTZ-16. We demonstrate this moderate MAS low-power decoupling technique on hydrated POPC lipid

  8. PILOT_PROTEIN: Identification of Unmodified and Modified Proteins via High-Resolution Mass Spectrometry and Mixed-Integer Linear

    E-Print Network [OSTI]

    Shorter, James

    accuracy with a lower false positive rate. All materials are freely available to the scientific community and protein identification and can help reduce the number of false positive resulPILOT_PROTEIN: Identification of Unmodified and Modified Proteins via High-Resolution Mass

  9. Journal of Glaciology, Vol. 57, No. 206, 2011 1087 Using high-resolution tritium profiles to quantify the effects of

    E-Print Network [OSTI]

    Moore, John

    to quantify the effects of melt on two Spitsbergen ice cores L.G. VAN DER WEL,1 H.J. STREURMAN,1 E. ISAKSSON,2 ABSTRACT. Ice cores from small ice caps provide valuable climatic information, additional. To determine to what extent this can affect such ice cores, we performed high-resolution tritium measurements

  10. ASTRO-H White Paper - High Resolution Spectroscopy of Interstellar and Circumgalactic Gas in the Milky Way and Other Galaxies

    E-Print Network [OSTI]

    Paerels, F; Anabuki, N; Costantini, E; de Vries, C; Fujimoto, R; Hornschemeier, A; Iizuka, R; Kilbourne, C; Konami, S; LaMassa, S; Loewenstein, M; McCammon, D; Matsushita, K; McNamara, B; Mitsuishi, I; Nagino, R; Nakagawa, T; Porter, S; Sakai, K; Smith, R K; Takei, Y; Tsuru, T; Uchiyama, H; Yamaguchi, H; Yamauchi, S

    2014-01-01T23:59:59.000Z

    We describe the potential of high resolution imaging spectroscopy with the SXS on ASTRO-H to advance our understanding of the interstellar- and circumgalactic media of our own Galaxy, and other galaxies. Topics to be addressed range from absorption spectroscopy of dust in the Galactic interstellar medium, to observations to constrain the total mass-, metal-, and energy flow out of starburst galaxies.

  11. High-resolution paleomagnetic secular variations and relative paleointensity since the Late Pleistocene in southern South America

    E-Print Network [OSTI]

    Beaudoin, Georges

    ; however the uneven distribution of the records on Earth does not allow addressing the possible global records from the Southern Hemisphere are rare. As a consequence, global stacks are truly derived from excursion at 20 ka cal BP. Nonetheless, a global-scale comparison with other high-resolution records located

  12. High-resolution geostatistical inversion of a seismic data set acquired in a Gulf of Mexico gas reservoir.

    E-Print Network [OSTI]

    Torres-Verdín, Carlos

    High-resolution geostatistical inversion of a seismic data set acquired in a Gulf of Mexico gas, UNOCAL Corporation Summary Geostatistical inversion is applied on a Gulf-of-Mexico, 3D post-stack seismic in this paper is located in the Gulf of Mexico, off the coast of Louisiana. Existing development wells reach two

  13. High resolution imaging and lithography using interference of light and surface plasmon waves

    E-Print Network [OSTI]

    Kim, Yang-Hyo

    2007-01-01T23:59:59.000Z

    The resolution of optical imaging and lithography is limited by the wave nature of light. Studies have been undertaken to overcome the diffraction limit for imaging and lithography. In our lab, the standing wave surface ...

  14. High resolution fossil fuel combustion CO2 emission fluxes for the United States

    E-Print Network [OSTI]

    Gurney, Kevin R.

    2010-01-01T23:59:59.000Z

    resolution fossil fuel combustion CO 2 emission fluxes for2002, includes detail on combustion technology and forty-atmosphere is that due to the combustion of fossil fuels and

  15. Surface Pressure Observations from Smartphones:3 A Potential Revolution for High-Resolution Weather Prediction?4

    E-Print Network [OSTI]

    Mass, Clifford F.

    -Resolution Weather Prediction?4 5 Clifford F. Mass1 and Luke E. Madaus6 Department of Atmospheric Sciences7 1 Corresponding author Professor Clifford F. Mass Department of Atmospheric Sciences Box 351640 about three-dimensional55 atmosph

  16. HIGH RESOLUTION PREDICTION OF GAS INJECTION PROCESS PERFORMANCE FOR HETEROGENEOUS RESERVOIRS

    SciTech Connect (OSTI)

    Franklin M. Orr, Jr.

    2003-09-30T23:59:59.000Z

    This report outlines progress in the first quarter of the extension of the DOE project ''High Resolution Prediction of Gas Injection Process Performance for Heterogeneous Reservoirs''. This report presents experimental results that demonstrate combined scaling effects of viscous, capillary, and gravity crossflow mechanisms that apply to the situations in which streamline models are used. We designed and ran a series of experiments to investigate combined effects of capillary, viscous, and gravity forces on displacement efficiency in layered systems. Analog liquids (isooctane, isopropanol, and water) were employed to control scaling parameters by changing interfacial tension (IFT), flow rate, and density difference. The porous medium was a two-dimensional (2-D) 2-layered glass bead model with a permeability ratio of about 1:4. In order to analyze the combined effect of only capillary and viscous forces, gravity effects were eliminated by changing the orientation of the glass bead model. We employed a commercial simulator, Eclipse100 to calculate displacement behavior for comparison with the experimental data. Experimental results with minimized gravity effects show that the IFT and flow rate determine how capillary and viscous forces affect behavior of displacement. The limiting behavior for scaling groups for two-phase displacement was verified by experimental results. Analysis of the 2-D images indicates that displacements having a capillary-viscous equilibrium give the best sweep efficiency. Experimental results with gravity effects, but with low IFT fluid systems show that slow displacements produce larger area affected by crossflow. This, in turn, enhances sweep efficiency. The simulation results represent the experimental data well, except for the situations where capillary forces dominate the displacement.

  17. HIGH-RESOLUTION, DIFFERENTIAL, NEAR-INFRARED TRANSMISSION SPECTROSCOPY OF GJ 1214b

    SciTech Connect (OSTI)

    Crossfield, I. J. M.; Hansen, Brad M. S. [Department of Physics and Astronomy, University of California Los Angeles, Los Angeles, CA 90095 (United States); Barman, Travis, E-mail: ianc@astro.ucla.edu [Lowell Observatory, 1400 West Mars Hill Road, Flagstaff, AZ 86001 (United States)

    2011-08-01T23:59:59.000Z

    The nearby star GJ 1214 hosts a planet intermediate in radius and mass between Earth and Neptune, resulting in some uncertainty as to its nature. We have observed this planet, GJ 1214b, during transit with the high-resolution, near-infrared NIRSPEC spectrograph on the Keck II telescope, in order to characterize the planet's atmosphere. By cross-correlating the spectral changes through transit with a suite of theoretical atmosphere models, we search for variations associated with absorption in the planet atmosphere. Our observations are sufficient to rule out tested model atmospheres with wavelength-dependent transit depth variations {approx}> 5 x 10{sup -4} over the wavelength range 2.1-2.4 {mu}m. Our sensitivity is limited by variable slit loss and telluric transmission effects. We find no positive signatures but successfully rule out a number of plausible atmospheric models, including the default assumption of a gaseous, H-dominated atmosphere in chemical equilibrium. Such an atmosphere can be made consistent if the absorption due to methane is reduced. Clouds can also render such an atmosphere consistent with our observations, but only if they lie higher in the atmosphere than indicated by recent optical and infrared measurements. When taken in concert with other observational constraints, our results support a model in which the atmosphere of GJ 1214b contains significant H and He, but where CH{sub 4} is depleted. If this depletion is the result of photochemical processes, it may also produce a haze that suppresses spectral features in the optical.

  18. High-resolution three-dimensional simulations of core-collapse supernovae in multiple progenitors

    SciTech Connect (OSTI)

    Couch, Sean M. [Flash Center for Computational Science, Department of Astronomy and Astrophysics, University of Chicago, Chicago, IL 60637 (United States); O'Connor, Evan P., E-mail: smc@flash.uchicago.edu [Canadian Institute for Theoretical Astrophysics, University of Toronto, Toronto, Ontario M5S 3H8 (Canada)

    2014-04-20T23:59:59.000Z

    Three-dimensional (3D) simulations of core-collapse supernovae (CCSNe) are granting new insight into the as-yet-uncertain mechanism that drives successful explosions. While there is still debate about whether explosions are obtained more easily in 3D than in 2D, it is undeniable that there exist qualitative and quantitative differences between the results of 3D and 2D simulations. We present an extensive set of high-resolution 1D, 2D, and 3D CCSN simulations with multispecies neutrino leakage carried out in two different progenitors. Our simulations confirm the results of Couch indicating that 2D explodes more readily than 3D. We argue that this is due to the inadequacies of 2D to accurately capture important aspects of the 3D dynamics. We find that without artificially enhancing the neutrino heating rate, we do not obtain explosions in 3D. We examine the development of neutrino-driven convection and the standing accretion shock instability (SASI) and find that, in separate regimes, either instability can dominate. We find evidence for growth of the SASI for both 15 M {sub ?} and 27 M {sub ?} progenitors; however, it is weaker in 3D exploding models. The growth rate of both instabilities is artificially enhanced along the symmetry axis in 2D as compared with our axis-free 3D Cartesian simulations. Our work highlights the growing consensus that CCSNe must be studied in 3D if we hope to solve the mystery of how the explosions are powered.

  19. High Resolution Near-Infrared Spectroscopy of FUors and FUor-like stars

    E-Print Network [OSTI]

    Tom Greene; Colin Aspin; Bo Reipurth

    2008-01-27T23:59:59.000Z

    We present new high resolution (R=18,000) near-infrared spectroscopic observations of a sample of classical FU Orionis stars (FUors) and other young stars with FUor characteristics that are sources of Herbig-Haro flows. Spectra are presented for the region 2.203 - 2.236 microns which is rich in absorption lines sensitive to both effective temperatures and surface gravities of stars. Both FUors and FUor-like stars show numerous broad and weak unidentified spectral features in this region. Spectra of the 2.280 - 2.300 micron region are also presented, with the 2.2935 micron v=2-0 CO absorption bandhead being clearly the strongest feature seen in the spectra all FUors and Fuor-like stars. A cross-correlation analysis shows that FUor and FUor-like spectra in the 2.203 - 2.236 micron region are not consistent with late-type dwarfs, giants, nor embedded protostars. The cross-correlations also show that the observed FUor-like Herbig-Haro energy sources have spectra that are substantively similar to those of FUors. Both object groups also have similar near-infrared colors. The large line widths and double-peaked nature of the spectra of the FUor-like stars are consistent with the established accretion disk model for FUors, also consistent with their near-infrared colors. It appears that young stars with FUor-like characteristics may be more common than projected from the relatively few known classical FUors.

  20. High-resolution microcalorimeter detectors as a tool in the future of nuclear safeguards

    SciTech Connect (OSTI)

    Hoteling, Nathan J [Los Alamos National Laboratory; Hoover, Andrew S [Los Alamos National Laboratory

    2010-01-01T23:59:59.000Z

    New measurements are presented from the LANL-NIST microcalorimeter array for two standard plutonium sources. The results demonstrate substantially smaller error bars obtained from the spectral analysis program FRAM. Some areas of improvement to the analysis technique have been identified, indicating that the micro calorimeter results can be improved upon. These results support the viability of a device for performing real nuclear safeguards measurements in the near future. The challenge of providing reliably accurate and precise data is a critical component of any safeguards initiative. In the realm of nuclear safeguards, this is an especially daunting task since inaccurate and/or imprecise data could have very serious international consequences. As such, there is a constant drive within the community to establish better measurement and analysis techniques in order to further reduce the associated errors and uncertainties. Even with todays state of the art equipment, measurement uncertainties can extend to several significant quantities worth of material over a relatively modest period of time. Furthermore, there is a strong desire for improved nondestructive analysis techniques in order to reduce both the cost, turnover rate, and inconvenience of destructive analyses. One promising new technology that may help to realize these goals is that of gamma-ray microcalorimeter detectors. The hallmark quality of this new technique is the ability to achieve energy resolution nearly an order of magnitude better than typical planar high-purity germanium (HPGe) detectors. Such an improvement may help reduce uncertainties associated with, for instance, plutonium isotopics or uranium enrichment measurements. This may, in turn, help to reduce uncertainties in total plutonium and/or uranium content in a given sample without the need for destructive analysis. In this paper, we will describe this new detector technology as well as some recent measurements carried out with the LANL-NIST gamma-ray microcalorimeter ({micro}cal) array. Discussion will focus on the capabilities of this technology as well as the progress toward a practical measurement device.

  1. Prospects for High Energy Resolution Gamma Ray Spectroscopy with Europium-Doped Strontium

    SciTech Connect (OSTI)

    Cherepy, Nerine [Lawrence Livermore National Laboratory (LLNL); Payne, Stephen A. [Lawrence Livermore National Laboratory (LLNL); Hawrami, Rastgo [Fisk University, Nashville, TN; Burger, Arnold [Fisk University, Nashville, TN; Boatner, Lynn A [ORNL; Van Loef, Edgar [Radiation Monitoring Devices, Watertown, MA; Shah, Kanai [Radiation Monitoring Devices, Watertown, MA

    2009-01-01T23:59:59.000Z

    Europium-doped strontium iodide scintillators offer a light yield exceeding 100,000 photons/MeV and excellent light yield proportionality, while at the same time, SrI2 is readily grown in single crystal form. Thus far, our collaboration has demonstrated an energy resolution with strontium iodide of 2.6% at 662 keV and 7.6% at 60 keV, and we have grown single crystals surpassing 30 cm3 in size (with lower resolution). Our analysis indicates that SrI2(Eu) has the potential to offer 2% energy resolution at 662 keV with optimized material, optics, and read-out. In particular, improvements in feedstock purity may result in crystal structural and chemical homogeneity, leading to improved light yield uniformity throughout the crystal volume, and consequently, better energy resolution. Uniform, efficient light collection and detection, is also required to achieve the best energy resolution with a SrI2(Eu) scintillator device.

  2. HIGH SPATIAL-RESOLUTION IMAGING OF TE INCLUSIONS IN CZT MATERIAL.

    SciTech Connect (OSTI)

    CAMARDA, G.S.; BOLOTNIKOV, A.E.; CARINI, G.A.; CUI, Y.; KOHMAN, K.T.; LI, L.; JAMES, R.B.

    2006-08-13T23:59:59.000Z

    We present new results from our studies of defects in current single-crystal CdZnTe material. Our previous measurements, carried out on thin ({approx}1 mm) and long (>12 mm) CZT detectors, indicated that small (1-20 {micro}m) Te inclusions can significantly degrade the device's energy resolution and detection efficiency. We are conducting detailed studies of the effects of Te inclusions by employing different characterization techniques with better spatial resolution, such as quantitative fluorescence mapping, X-ray micro-diffraction, and TEM. Also, IR microscopy and gamma-mapping with pulse-shape analysis with higher spatial resolution generated more accurate results in the areas surrounding the micro-defects (Te inclusions). Our results reveal how the performance of CdZnTe detectors is influenced by Te inclusions, such as their spatial distribution, concentration, and size. We also discuss a model of charge transport through areas populated with Te inclusions.

  3. Wide-open, high-resolution microwave/millimeter-wave Doppler frequency shift estimation using photonics technology

    E-Print Network [OSTI]

    Zou, Xihua; Lu, Bing; Pan, Wei; Yan, Lianshan; Shao, Liyang

    2014-01-01T23:59:59.000Z

    Today, wide-open, high-resolution Doppler frequency shift (DFS) estimation is essential for radar, microwave/millimeter-wave, and communication systems. Using photonics technology, an effective approach is proposed and experimentally demonstrated, providing a high-resolution and frequency-independent solution. In the approach consisting of two cascaded opto-electronic modulators, DFS between the transmitted microwave/ millimeter-wave signal and the received echo signal is mapped into a doubled spacing between two target optical sidebands. Subsequently, the DFS is then estimated through the spectrum analysis of a generated low-frequency electrical signal, with an improved resolution by a factor of 2. In experiments, DFSs from -90 to 90 KHz are successfully estimated for microwave/millimeter-wave signals at 10, 15, and 30 GHz, where estimation errors keep lower than +/- 5e-10 Hz. For radial velocity measurement, these results reveal a range from 0 to 900 m/s (0 to 450 m/s) and a resolution of 1e-11 m/s (5e-12 m...

  4. Characterizing Aerosol Distributions and Optical Properties Using the NASA Langley High Spectral Resolution Lidar

    SciTech Connect (OSTI)

    Hostetler, Chris; Ferrare, Richard

    2013-02-14T23:59:59.000Z

    The objective of this project was to provide vertically and horizontally resolved data on aerosol optical properties to assess and ultimately improve how models represent these aerosol properties and their impacts on atmospheric radiation. The approach was to deploy the NASA Langley Airborne High Spectral Resolution Lidar (HSRL) and other synergistic remote sensors on DOE Atmospheric Science Research (ASR) sponsored airborne field campaigns and synergistic field campaigns sponsored by other agencies to remotely measure aerosol backscattering, extinction, and optical thickness profiles. Synergistic sensors included a nadir-viewing digital camera for context imagery, and, later in the project, the NASA Goddard Institute for Space Studies (GISS) Research Scanning Polarimeter (RSP). The information from the remote sensing instruments was used to map the horizontal and vertical distribution of aerosol properties and type. The retrieved lidar parameters include profiles of aerosol extinction, backscatter, depolarization, and optical depth. Products produced in subsequent analyses included aerosol mixed layer height, aerosol type, and the partition of aerosol optical depth by type. The lidar products provided vertical context for in situ and remote sensing measurements from other airborne and ground-based platforms employed in the field campaigns and was used to assess the predictions of transport models. Also, the measurements provide a data base for future evaluation of techniques to combine active (lidar) and passive (polarimeter) measurements in advanced retrieval schemes to remotely characterize aerosol microphysical properties. The project was initiated as a 3-year project starting 1 January 2005. It was later awarded continuation funding for another 3 years (i.e., through 31 December 2010) followed by a 1-year no-cost extension (through 31 December 2011). This project supported logistical and flight costs of the NASA sensors on a dedicated aircraft, the subsequent analysis and archival of the data, and the presentation of results in conferences, workshops, and publications. DOE ASR field campaigns supported under this project included - MAX-Mex /MILAGRO (2006) - TexAQS 2006/GoMACCS (2006) - CHAPS (2007) - RACORO (2009) - CARE/CalNex (2010) In addition, data acquired on HSRL airborne field campaigns sponsored by other agencies were used extensively to fulfill the science objectives of this project and the data acquired have been made available to other DOE ASR investigators upon request.

  5. Photoacoustic tomography of biological tissues with high cross-section resolution: Reconstruction and experiment

    E-Print Network [OSTI]

    Wang, Lihong

    27 November 2002 A modified back-projection approach deduced from an exact reconstruction solution was applied to our photoacoustic tomography of the optical absorption in biological tissues. Pulses from a Ti:sap a spatial resolution around 10 m.8 All of the above photoacoustic tomography systems can be categorized

  6. DESCRIPTION AND STATUS OF THE HIGH RESOLUTION (HIRES) FLY'S EYE EXPERIMENT.

    E-Print Network [OSTI]

    as well as a lack of statistics. This lack of information has thwarted theoretical efforts to conclusively. Boyer, C. Y. Chi, Y. Ho, W. Lee, J. Mechalakos, Department of Physics, Colombia University 538 W. 120 St improved energy, directional and shower development resolution, combined with the event statistics

  7. 95The Apollo-11 Landing Area at High-Resolution The Lunar Reconnaissance Orbiter (LRO) recently imaged the Apollo-11 landing

    E-Print Network [OSTI]

    95The Apollo-11 Landing Area at High-Resolution The Lunar Reconnaissance Orbiter (LRO) recently imaged the Apollo-11 landing area at high-resolution and obtained the image above (top left of the Apollo-11 lander is 8mm in diameter, or 8 mm x (4.8 meters/mm) = 24 meters in diameter. The smallest

  8. Measurement method for roll angular displacement with a high resolution by using diffraction gratings and a heterodyne interferometer

    SciTech Connect (OSTI)

    Tang, Shanzhi, E-mail: shanzhit@gmail.com [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China) [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049 (China); Wang, Zhao [School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049 (China)] [School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049 (China); Gao, Jianmin; Guo, Junjie [State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710054 (China)] [State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710054 (China)

    2014-04-15T23:59:59.000Z

    The roll angle measurement is difficult to be achieved directly using a typical commercial interferometer due to its low sensitivity in axial direction, where the axial direction is orthogonal to the plane of the roll angular displacement. A roll angle measurement method combined diffraction gratings with a laser heterodyne interferometer is discussed in this paper. The diffraction grating placed in the plane of a roll angular displacement and the interferometer arranged in the plane's orthogonal direction, constitute the measurement pattern for the roll angle with high resolution. The roll angular displacement, considered as the linear, can be tested precisely when the corresponding angle is very small. Using the proposed method, the angle roll measurement obtains the high resolution of 0.002{sup ?}. Experiment has proved its feasibility and practicability.

  9. High Resolution Optically Addressed Spatial Light Modulator based on ZnO Nanoparticles

    E-Print Network [OSTI]

    Shrestha, Pawan Kumar; Chun, Young Tea; Chu, Daping

    2015-01-01T23:59:59.000Z

    temperatures. (d) Temporal current response with and without illumination. Samples are illuminated by 10 mW cm -2 of 365 nm light emitting diode with 6 V dc being applied throughout. Electrical characterization For conductivity measurement, two rectangular... of the corresponding dark/photo currents of the ITO-ZnO-ITO structures are carried out using Agilent 4156 together with a 365 nm light emitting diode light source of 2 mW cm-2. The conductivity, ? , of the sample is calculated as, dI LtV? ? (2) where, d...

  10. High-Resolution Carbon Isotope Stratigraphy, Pennsylvanian Snaky Canyon Formation, East-Central Idaho: Implications for Regional and Global Correlations

    E-Print Network [OSTI]

    Jolley, Casey

    2012-07-16T23:59:59.000Z

    of Committee, Michael C. Pope Committee Members, Ethan L. Grossman Debbie J. Thomas Head of Department, Rick Giardino May 2012 Major Subject: Geology iii ABSTRACT High-Resolution Carbon Isotope Stratigraphy, Pennsylvanian Snaky Canyon..., and my committee members, Dr. Ethan Grossman and Dr. Debbie Thomas, for their time and guidance. Special thanks goes to my primary advisor, Dr. Pope, for his extra guidance and time away from family collecting samples. Additionally, I?d like to thank...

  11. HIGH-RESOLUTION SPECTROSCOPY OF EXTREMELY METAL-POOR STARS FROM SDSS/SEGUE. I. ATMOSPHERIC PARAMETERS AND CHEMICAL COMPOSITIONS

    SciTech Connect (OSTI)

    Aoki, Wako; Suda, Takuma [National Astronomical Observatory, Mitaka, Tokyo 181-8588 (Japan); Beers, Timothy C. [National Optical Astronomy Observatory, Tucson, AZ 85719 (United States); Lee, Young Sun [Department of Physics and Astronomy and JINA: Joint Institute for Nuclear Astrophysics, Michigan State University, East Lansing, MI 48824 (United States); Honda, Satoshi [Kwasan Observatory, Kyoto University, Ohmine-cho Kita Kazan, Yamashin a-ku, Kyoto 607-8471 (Japan); Ito, Hiroko [Department of Astronomical Science, School of Physical Sciences, The Graduate University of Advanced Studies (SOKENDAI), 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan); Takada-Hidai, Masahide [Liberal Arts Education Center, Tokai University, 4-1-1 Kitakaname, Hiratsuka, Kanagawa 259-1292 (Japan); Frebel, Anna [Massachusetts Institute of Technology, Kavli Institute for Astrophysics and Space Research, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States); Fujimoto, Masayuki Y. [Department of Cosmosciences, Graduate School of Science, Hokkaido University, Kita 10 Nishi 8, Kita-ku, Sapporo 060-0810 (Japan); Carollo, Daniela [Department of Physics and Astronomy, Astronomy, Astrophysics, and Astrophotonic Research Center, Macquarie University North Ryde, NSW 2109 (Australia); Sivarani, Thirupathi, E-mail: aoki.wako@nao.ac.jp, E-mail: takuma.suda@nao.ac.jp, E-mail: beers@noao.edu, E-mail: lee@pa.msu.edu, E-mail: honda@kwasan.kyoto-u.ac.jp, E-mail: hidai@apus.rh.u-tokai.ac.jp, E-mail: afrebel@mit.edu, E-mail: fujimoto@astro1.sci.hokudai.ac.jp, E-mail: daniela.carollo@mq.edu.au, E-mail: sivarani@iiap.res.in [Indian Institute of Astrophysics, 2nd block Koramangala, Bangalore 560034 (India)

    2013-01-01T23:59:59.000Z

    Chemical compositions are determined based on high-resolution spectroscopy for 137 candidate extremely metal-poor (EMP) stars selected from the Sloan Digital Sky Survey (SDSS) and its first stellar extension, the Sloan Extension for Galactic Understanding and Exploration (SEGUE). High-resolution spectra with moderate signal-to-noise (S/N) ratios were obtained with the High Dispersion Spectrograph of the Subaru Telescope. Most of the sample (approximately 80%) are main-sequence turnoff stars, including dwarfs and subgiants. Four cool main-sequence stars, the most metal-deficient such stars known, are included in the remaining sample. Good agreement is found between effective temperatures estimated by the SEGUE stellar parameter pipeline, based on the SDSS/SEGUE medium-resolution spectra, and those estimated from the broadband (V - K){sub 0} and (g - r){sub 0} colors. Our abundance measurements reveal that 70 stars in our sample have [Fe/H] < -3, adding a significant number of EMP stars to the currently known sample. Our analyses determine the abundances of eight elements (C, Na, Mg, Ca, Ti, Cr, Sr, and Ba) in addition to Fe. The fraction of carbon-enhanced metal-poor stars ([C/Fe] > +0.7) among the 25 giants in our sample is as high as 36%, while only a lower limit on the fraction (9%) is estimated for turnoff stars. This paper is the first of a series of papers based on these observational results. The following papers in this series will discuss the higher-resolution and higher-S/N observations of a subset of this sample, the metallicity distribution function, binarity, and correlations between the chemical composition and kinematics of extremely metal-poor stars.

  12. High-resolution magnetohydrodynamics simulation of black hole-neutron star merger: Mass ejection and short gamma-ray burst

    E-Print Network [OSTI]

    Kiuchi, Kenta; Kyutoku, Koutarou; Shibata, Masaru; Taniguchi, Keisuke; Wada, Tomohide

    2015-01-01T23:59:59.000Z

    We report results of a high-resolution numerical-relativity simulation for the merger of black hole-magnetized neutron star binaries on Japanese supercomputer "K". We focus on a binary that is subject to tidal disruption and subsequent formation of a massive accretion torus. We find the launch of thermally driven torus wind, subsequent formation of a funnel wall above the torus and a magnetosphere with collimated poloidal magnetic field, and high Blandford-Znajek luminosity. We show for the first time this picture in a self-consistent simulation. The turbulence-like motion induced by the non-axisymmetric magnetorotational instability as well as the Kelvin-Helmholtz instability inside the accretion torus works as an agent to drive the mass accretion and converts the accretion energy to thermal energy, which results in the generation of a strong wind. By an in-depth resolution study, we reveal that high resolution is essential to draw such a picture. We also discuss the implication for the r-process nucleosynth...

  13. Direct Observation of Cosmic Strings via their Strong Gravitational Lensing Effect: I. Predictions for High Resolution Imaging Surveys

    E-Print Network [OSTI]

    Maria Alice Gasparini; Phil Marshall; Tommaso Treu; Eric Morganson; Florian Dubath

    2007-12-21T23:59:59.000Z

    We use current theoretical estimates for the density of long cosmic strings to predict the number of strong gravitational lensing events in astronomical imaging surveys as a function of angular resolution and survey area. We show that angular resolution is the most important factor, and that interesting limits on the dimensionless string tension Gmu/c^2 can be obtained by existing and planned surveys. At the resolution of the Hubble Space Telescope (0.14"), it is sufficient to survey of order a few square degrees -- well within reach of the current HST archive -- to probe the regime Gmu/c^2 ~ 10^{-7}. If lensing by cosmic strings is not detected, such a survey would improve the limit on the string tension by a factor of two over that available from the cosmic microwave background. Future high resolution imaging surveys, covering a few hundred square degrees or more, either from space in the optical or from large-format radio telescopes on the ground, would be able to further lower this limit to Gmu/c^2 < 10^{-8}.

  14. Ultra-high-resolution Observations of MHD Waves in Photospheric Magnetic Structures

    E-Print Network [OSTI]

    Jess, David B

    2015-01-01T23:59:59.000Z

    Here we review the recent progress made in the detection, examination, characterisation and interpretation of oscillations manifesting in small-scale magnetic elements in the solar photosphere. This region of the Sun's atmosphere is especially dynamic, and importantly, permeated with an abundance of magnetic field concentrations. Such magnetic features can span diameters of hundreds to many tens of thousands of km, and are thus commonly referred to as the `building blocks' of the magnetic solar atmosphere. However, it is the smallest magnetic elements that have risen to the forefront of solar physics research in recent years. Structures, which include magnetic bright points, are often at the diffraction limit of even the largest of solar telescopes. Importantly, it is the improvements in facilities, instrumentation, imaging techniques and processing algorithms during recent years that have allowed researchers to examine the motions, dynamics and evolution of such features on the smallest spatial and temporal ...

  15. The Space Infrared Interferometric Telescope (SPIRIT): High-resolution imaging and spectroscopy in the far-infrared

    E-Print Network [OSTI]

    David Leisawitz; Charles Baker; Amy Barger; Dominic Benford; Andrew Blain; Rob Boyle; Richard Broderick; Jason Budinoff; John Carpenter; Richard Caverly; Phil Chen; Steve Cooley; Christine Cottingham; Julie Crooke; Dave DiPietro; Mike DiPirro; Michael Femiano; Art Ferrer; Jacqueline Fischer; Jonathan P. Gardner; Lou Hallock; Kenny Harris; Kate Hartman; Martin Harwit; Lynne Hillenbrand; Tupper Hyde; Drew Jones; Jim Kellogg; Alan Kogut; Marc Kuchner; Bill Lawson; Javier Lecha; Maria Lecha; Amy Mainzer; Jim Mannion; Anthony Martino; Paul Mason; John Mather; Gibran McDonald; Rick Mills; Lee Mundy; Stan Ollendorf; Joe Pellicciotti; Dave Quinn; Kirk Rhee; Stephen Rinehart; Tim Sauerwine; Robert Silverberg; Terry Smith; Gordon Stacey; H. Philip Stahl; Johannes Staguhn; Steve Tompkins; June Tveekrem; Sheila Wall; Mark Wilson

    2007-07-05T23:59:59.000Z

    We report results of a recently-completed pre-Formulation Phase study of SPIRIT, a candidate NASA Origins Probe mission. SPIRIT is a spatial and spectral interferometer with an operating wavelength range 25 - 400 microns. SPIRIT will provide sub-arcsecond resolution images and spectra with resolution R = 3000 in a 1 arcmin field of view to accomplish three primary scientific objectives: (1) Learn how planetary systems form from protostellar disks, and how they acquire their inhomogeneous composition; (2) characterize the family of extrasolar planetary systems by imaging the structure in debris disks to understand how and where planets of different types form; and (3) learn how high-redshift galaxies formed and merged to form the present-day population of galaxies. Observations with SPIRIT will be complementary to those of the James Webb Space Telescope and the ground-based Atacama Large Millimeter Array. All three observatories could be operational contemporaneously.

  16. Experimentally characterizing the electronic structures of f-electron systems using advanced high resolution Fourier transform microwave spectroscopies

    SciTech Connect (OSTI)

    Cooke, Stephen, A

    2013-02-03T23:59:59.000Z

    We aim to (i) provide data that directly addresses the fundamental roles of actinide valence electrons in chemical bonding, and (ii) serve to provide prototypical data for the heavy element computational chemistry community. These goals will be achieved through the first pure rotational spectroscopic measurements on prototypical systems at ultra-high resolution. These systems encompass low oxidation state uranium and thorium compounds including, but not limited to, UX and ThX, X = F, Cl, Br, I, and UY and ThY, Y = O, S, and other simple U and Th-containing compounds. Our primary experimental tools involve time-domain rotational spectroscopy achieving line widths and resolutions of a few kHz.

  17. High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array

    SciTech Connect (OSTI)

    Noroozian, Omid [National Institute of Standards and Technology, Boulder, Colorado 80305 (United States) [National Institute of Standards and Technology, Boulder, Colorado 80305 (United States); Center for Astrophysics and Space Astronomy, University of Colorado, Boulder, Colorado 80309 (United States); Mates, John A. B.; Bennett, Douglas A.; Brevik, Justus A.; Fowler, Joseph W.; Gao, Jiansong; Hilton, Gene C.; Horansky, Robert D.; Irwin, Kent D.; Schmidt, Daniel R.; Vale, Leila R.; Ullom, Joel N. [National Institute of Standards and Technology, Boulder, Colorado 80305 (United States)] [National Institute of Standards and Technology, Boulder, Colorado 80305 (United States); Kang, Zhao [Department of Physics, University of Colorado, Boulder, Colorado 80309 (United States)] [Department of Physics, University of Colorado, Boulder, Colorado 80309 (United States)

    2013-11-11T23:59:59.000Z

    We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a {sup 153}Gd photon source and achieved an energy resolution of 63 eV full-width-at-half-maximum at 97 keV and an equivalent readout system noise of 86 pA/?(Hz) at the TES. The readout circuit consists of superconducting microwave resonators coupled to radio-frequency superconducting-quantum-interference-devices and transduces changes in input current to changes in phase of a microwave signal. We use flux-ramp modulation to linearize the response and evade low-frequency noise. This demonstration establishes one path for the readout of cryogenic X-ray and gamma-ray sensor arrays with more than 10{sup 3} elements and spectral resolving powers R=?/??>10{sup 3}.

  18. Analysis of hydraulic tomography using temporal moments of drawdown recovery data

    E-Print Network [OSTI]

    Daniels, Jeffrey J.

    Analysis of hydraulic tomography using temporal moments of drawdown recovery data Junfeng Zhu 2006. [1] Transient hydraulic tomography (THT) is a potentially cost-effective and high- resolution technique for mapping spatial distributions of the hydraulic conductivity and specific storage in aquifers

  19. All-optical high-resolution magnetic resonance using a nitrogen-vacancy spin in diamond

    E-Print Network [OSTI]

    Zhen-Yu Wang; Jian-Ming Cai; Alex Retzker; Martin B. Plenio

    2014-04-04T23:59:59.000Z

    We propose an all-optical scheme to prolong the quantum coherence of a negatively charged nitrogen-vacancy (NV) center in diamond. Optical control of the NV spin suppresses energy fluctuations of the $^{3}\\text{A}_{2}$ ground states and forms an energy gap protected subspace. By optical control, the spectral linewidth of magnetic resonance is much narrower and the measurement of the frequencies of magnetic field sources has higher resolution. The optical control also improves the sensitivity of the magnetic field detection and can provide measurement of the directions of signal sources.

  20. A numerical investigation of high resolution multispectral absorption tomography for flow thermometry

    E-Print Network [OSTI]

    Cai, Weiwei; Kaminski, Clemens F.

    2015-02-01T23:59:59.000Z

    resolution at the cost of increased data acquisition requirement. We demonstrate this effect by increasing the spatial sam- pling frequency along each projection direction. This finer meshing of the flow filed is permissible under the assump- tion... dominant broadening mechanisms, (1) ?(?) = L2 ? L1 ? g S[T(l), ?g] · ?[T(l),X(l),P, (?g ? ?)] · P · X(l) i.e., Doppler and collisional broadening, representative for typical combustion scenarios; and S[T(l), ?g] is the line strength of the gth non...

  1. Property:TemporalResolution | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere I GeothermalPotentialBiopowerSolidGenerationMethod Jump to:This property isType" Showing 25 pages

  2. JOURNAL OF GEOPHYSICAL RESEARCH, VOL. ???, XXXX, DOI:10.1029/, A three-dimensional eddy census of a high-resolution1

    E-Print Network [OSTI]

    California at Davis, University of

    of a high-resolution1 global ocean simulation2 Mark R. Petersen, 1 Sean J. Williams, 1,2 Mathew E. Maltrud census data set was obtained from3 a global ocean simulation with one-tenth degree resolution are at least 1000m tall, and many penetrate the14 full depth of the water column. The Antarctic Circumpolar

  3. JOURNAL OF GEOPHYSICAL RESEARCH: OCEANS, VOL. 118, 17591 , doi:10.1002/jgrc.20155, 2013 A three-dimensional eddy census of a high-resolution global

    E-Print Network [OSTI]

    Hamann, Bernd

    JOURNAL OF GEOPHYSICAL RESEARCH: OCEANS, VOL. 118, 1759­1 , doi:10.1002/jgrc.20155, 2013 A three-dimensional eddy census of a high-resolution global ocean simulation Mark R. Petersen,1 Sean J. Williams,1,2 Mathew from a global ocean simulation with one-tenth degree resolution and a duration of 7 years. The census

  4. The roughness of stylolites: Implications of 3D high resolution topography measurements

    E-Print Network [OSTI]

    Boyer, Edmond

    diagenesis and metamorphism that develop after their initiation. In this Letter we show the first 3D high

  5. CHEMICAL ABUNDANCES IN FIELD RED GIANTS FROM HIGH-RESOLUTION H-BAND SPECTRA USING THE APOGEE SPECTRAL LINELIST

    SciTech Connect (OSTI)

    Smith, Verne V.; Cunha, Katia [National Optical Astronomy Observatories, Tucson, AZ 85719 (United States)] [National Optical Astronomy Observatories, Tucson, AZ 85719 (United States); Shetrone, Matthew D. [Department of Astronomy and McDonald Observatory, University of Texas, Austin, TX 78712 (United States)] [Department of Astronomy and McDonald Observatory, University of Texas, Austin, TX 78712 (United States); Meszaros, Szabolcs; Allende Prieto, Carlos [Instituto d'Astrofisica de Canarias, E-38205, La Laguna, Tenerife (Spain)] [Instituto d'Astrofisica de Canarias, E-38205, La Laguna, Tenerife (Spain); Bizyaev, Dmitry [Apache Point Observatory, Sunspot, NM 88349 (United States)] [Apache Point Observatory, Sunspot, NM 88349 (United States); Garcia Perez, Ana; Majewski, Steven R. [Department of Astronomy, University of Virginia, Charlottesville, VA 22904 (United States)] [Department of Astronomy, University of Virginia, Charlottesville, VA 22904 (United States); Schiavon, Ricardo [Astrophysics Research Institute, Liverpool John Moores University, Liverpool L3 5UX (United Kingdom)] [Astrophysics Research Institute, Liverpool John Moores University, Liverpool L3 5UX (United Kingdom); Holtzman, Jon [Department of Astronomy, New Mexico State University, Las Cruces, NM 88003 (United States)] [Department of Astronomy, New Mexico State University, Las Cruces, NM 88003 (United States); Johnson, Jennifer A., E-mail: vsmith@noao.edu [Department of Astronomy, Ohio State University, Columbus, OH 43210 (United States)

    2013-03-01T23:59:59.000Z

    High-resolution H-band spectra of five bright field K, M, and MS giants, obtained from the archives of the Kitt Peak National Observatory Fourier transform spectrometer, are analyzed to determine chemical abundances of 16 elements. The abundances were derived via spectrum synthesis using the detailed linelist prepared for the Sloan Digital Sky Survey III Apache Point Galactic Evolution Experiment (APOGEE), which is a high-resolution near-infrared spectroscopic survey to derive detailed chemical abundance distributions and precise radial velocities for 100,000 red giants sampling all Galactic stellar populations. The red giant sample studied here was chosen to probe which chemical elements can be derived reliably from the H-band APOGEE spectral region. These red giants consist of two K-giants ({alpha} Boo and {mu} Leo), two M-giants ({beta} And and {delta} Oph), and one thermally pulsing asymptotic giant branch (TP-AGB) star of spectral type MS (HD 199799). Measured chemical abundances include the cosmochemically important isotopes {sup 12}C, {sup 13}C, {sup 14}N, and {sup 16}O, along with Mg, Al, Si, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, and Cu. The K and M giants exhibit the abundance signature of the first dredge-up of CN-cycle material, while the TP-AGB star shows clear evidence of the addition of {sup 12}C synthesized during {sup 4}He-burning thermal pulses and subsequent third dredge-up. A comparison of the abundances derived here with published values for these stars reveals consistent results to {approx}0.1 dex. The APOGEE spectral region and linelist is thus well suited for probing both Galactic chemical evolution, as well as internal nucleosynthesis and mixing in populations of red giants via high-resolution spectroscopy.

  6. Results of the High Resolution OTR Measurements at KEK and comparison with simulations

    E-Print Network [OSTI]

    Bolzon, B; Mazzoni, S; Welsch, C P; Karataev, P; Kruchinin, K; Aryshev, A

    2013-01-01T23:59:59.000Z

    Optical Transition Radiation (OTR) is emitted when a charged particle crosses the interface between two media with different dielectric properties. It has become a standard tool for beam imaging and transverse beam size measurements. At the KEK Accelerator Test Facility 2 (ATF2), OTR is used at the beginning of the final focus system to measure micrometre beam size using the visibility of the OTR Point Spread Function (PSF). In order to study in detail the PSF and improve the resolution of the monitor, a novel simulation tool has been developed. Based on the physical optic propagation mode of ZEMAX, the propagation of the OTR electric field can be simulated very precisely up to the image plane, taking into account aberrations and diffraction. This contribution presents the comparison between Zemax simulations and measurements performed at ATF2.

  7. Large zenith angle observations with the high-resolution GRANITE III camera

    E-Print Network [OSTI]

    D. Petry; the VERITAS Collaboration

    2001-08-06T23:59:59.000Z

    The GRANITE III camera of the Whipple Cherenkov Telescope at the Fred Lawrence Whipple Observatory on Mount Hopkins, Arizona (2300 m a.s.l.) has the highest angular resolution of all cameras used on this telescope so far. The central region of the camera has 379 pixels with an individual angular diameter of 0.12 degrees. This makes the instrument especially suitable for observations of gamma-induced air-showers at large zenith angles since the increase in average distance to the shower maximum leads to smaller shower images in the focal plane of the telescope. We examine the performance of the telescope for observations of gamma-induced air-showers at zenith angles up to 63 degrees based on observations of Mkn 421 and using Monte Carlo Simulations. An improvement to the standard data analysis is suggested.

  8. Large zenith angle observations with the high-resolution GRANITE III camera

    E-Print Network [OSTI]

    Petry, D

    2001-01-01T23:59:59.000Z

    The GRANITE III camera of the Whipple Cherenkov Telescope at the Fred Lawrence Whipple Observatory on Mount Hopkins, Arizona (2300 m a.s.l.) has the highest angular resolution of all cameras used on this telescope so far. The central region of the camera has 379 pixels with an individual angular diameter of 0.12 degrees. This makes the instrument especially suitable for observations of gamma-induced air-showers at large zenith angles since the increase in average distance to the shower maximum leads to smaller shower images in the focal plane of the telescope. We examine the performance of the telescope for observations of gamma-induced air-showers at zenith angles up to 63 degrees based on observations of Mkn 421 and using Monte Carlo Simulations. An improvement to the standard data analysis is suggested.

  9. CONSTRAINING THE PLANETARY SYSTEM OF FOMALHAUT USING HIGH-RESOLUTION ALMA OBSERVATIONS

    SciTech Connect (OSTI)

    Boley, A. C.; Payne, M. J.; Ford, E. B.; Shabram, M. [Department of Astronomy, University of Florida, 211 Bryant Space Science Center, Gainesville, FL 32611 (United States); Corder, S. [North American ALMA Science Center, National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22903 (United States); Dent, W. R. F. [ALMA, Alonso de Cordova 3107, Vitacura, Santiago (Chile)

    2012-05-01T23:59:59.000Z

    The dynamical evolution of planetary systems leaves observable signatures in debris disks. Optical images trace micron-sized grains, which are strongly affected by stellar radiation and need not coincide with their parent body population. Observations of millimeter-sized grains accurately trace parent bodies, but previous images lack the resolution and sensitivity needed to characterize the ring's morphology. Here we present ALMA 350 GHz observations of the Fomalhaut debris ring. These observations demonstrate that the parent body population is 13-19 AU wide with a sharp inner and outer boundary. We discuss three possible origins for the ring and suggest that debris confined by shepherd planets is the most consistent with the ring's morphology.

  10. Cryogenic microcalorimeter system for ultra-high resolution alpha-particle spectrometry

    SciTech Connect (OSTI)

    Rabin, Michael W [Los Alamos National Laboratory; Hoover, Andrew S [Los Alamos National Laboratory; Bacrania, Mnesh K [Los Alamos National Laboratory; Croce, Mark P [Los Alamos National Laboratory; Hoteling, N J [Los Alamos National Laboratory; Lamont, S P [Los Alamos National Laboratory; Plionis, A A [Los Alamos National Laboratory; Dry, D E [Los Alamos National Laboratory; Ullom, J N [NIST; Bennett, D A [NIST; Horansky, R [NIST; Kotsubo, V [NIST; Cantor, R [STAR CRYOELECTRONICS

    2009-01-01T23:59:59.000Z

    Microcalorimeters have been shown to yield unsurpassed energy resolution for alpha spectrometry, up to 1.06 keV FWHM at 5.3 MeV. These detectors use a superconducting transition-edge sensor (TES) to measure the temperature change in an absorber from energy deposited by an interacting alpha particle. Our system has four independent detectors mounted inside a liquid nitrogen/liquid helium cryostat. An adiabatic demagnetization refrigerator (ADR) cools the detector stage to its operating temperature of 80 mK. Temperature regulation with {approx}15 uK peak-to-peak variation is achieved by PID control of the ADR. The detectors are voltage-biased, and the current signal is amplified by a commercial SQUID readout system and digitized for further analysis, This paper will discuss design and operation of our microcalorimeter alpha spectrometer, and will show recent results.

  11. High Resolution RANS NLH Study of Stage 67 Tip Injection Physics

    SciTech Connect (OSTI)

    Matheson, Michael A [ORNL

    2014-01-01T23:59:59.000Z

    Numerical prediction of the Stage 67 transonic fan stage employing wall jet tip injection flow control and study of the physical mechanisms leading to stall suppression and stability enhancement afforded by endwall recirculation/injection is the focus of this paper. Reynolds averaged Navier-Stokes computations were used to perform detailed analysis of the Stage 67 configuration experimentally tested at NASA s Glenn Research Center in 2004. Time varying prediction of the stage plus recirculation and injection flowpath were performed utilizing the Nonlinear Harmonic approach. Significantly higher grid resolution per passage was achieved than what has been generally employed in prior reported numerical studies of spike stall phenomena in transonic compressors. This paper focuses on characterizing the physics of spike stall embryonic stage phenomena and the impact of tip injection, resulting in experimentally and numerically demonstrated stall suppression

  12. Apparatus and method to achieve high-resolution microscopy with non-diffracting or refracting radiation

    DOE Patents [OSTI]

    Tobin, Jr., Kenneth W.; Bingham, Philip R.; Hawari, Ayman I.

    2012-11-06T23:59:59.000Z

    An imaging system employing a coded aperture mask having multiple pinholes is provided. The coded aperture mask is placed at a radiation source to pass the radiation through. The radiation impinges on, and passes through an object, which alters the radiation by absorption and/or scattering. Upon passing through the object, the radiation is detected at a detector plane to form an encoded image, which includes information on the absorption and/or scattering caused by the material and structural attributes of the object. The encoded image is decoded to provide a reconstructed image of the object. Because the coded aperture mask includes multiple pinholes, the radiation intensity is greater than a comparable system employing a single pinhole, thereby enabling a higher resolution. Further, the decoding of the encoded image can be performed to generate multiple images of the object at different distances from the detector plane. Methods and programs for operating the imaging system are also disclosed.

  13. High-resolution tangential absolute extreme ultraviolet arrays for radiated power density measurements on NSTX-U

    SciTech Connect (OSTI)

    Delgado-Aparicio, L.; Bell, R. E.; Diallo, A.; Gerhardt, S. P.; Kozub, T. A.; LeBlanc, B. P.; Stratton, B. C. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540 (United States); Faust, I. [MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139 (United States); Tritz, K. [The Johns Hopkins University, Baltimore, Maryland 21209 (United States)

    2014-11-15T23:59:59.000Z

    The radiated-power-density diagnostic on the equatorial midplane for the NSTX-U tokamak will be upgraded to measure the radial structure of the photon emissivity profile with an improved radial resolution. This diagnostic will enhance the characterization and studies of power balance, impurity transport, and MHD. The layout and response expected of the new system is shown for different plasma conditions and impurity concentrations. The effect of toroidal rotation driving poloidal asymmetries in the core radiation from high-Z impurities is also addressed.

  14. High resolution study of the Lambda p final state interaction in the reaction p + p -> K+ + (Lambda p)

    E-Print Network [OSTI]

    A. Budzanowski; A. Chatterjee; H. Clement; E. Dorochkevitch; P. Hawranek; F. Hinterberger; R. Jahn; R. Joosten; K. Kilian; S. Kliczewski; Da. Kirillov; Di. Kirillov; D. Kolev; M. Kravcikova; M. Lesiak; H. Machner; A. Magiera; G. Martinska; N. Piskunov; J. Ritman; P. von Rossen; B. J. Roy; A. Sibirtsev; I. Sitnik; R. Siudak; R. Tsenov; K. Ulbrich; J. Urban; G. J. Wagner

    2010-03-01T23:59:59.000Z

    The reaction pp -> K+ + (Lambda p) was measured at Tp=1.953 GeV and Theta = 0 deg with a high missing mass resolution in order to study the Lambda p final state interaction. The large final state enhancement near the Lambda p threshold can be described using the standard Jost-function approach. The singlet and triplet scattering lengths and effective ranges are deduced by fitting simultaneously the Lambda p invariant mass spectrum and the total cross section data of the free Lambda p scattering.

  15. High-resolution spectroscopy of V854 Cen in decline - Absorption and emission lines of C_2 molecules

    E-Print Network [OSTI]

    N. Kameswara Rao; David L. Lambert

    2000-02-10T23:59:59.000Z

    High-resolution optical spectra of the R Coronae Borealis (RBC) star V854 Centauri in the early stages of a decline show, in addition to the features reported for other RCBs in decline, narrow absorption lines from the C_2 Phillips system. The low rotational temperature, T_rot = 1150K, of the C_2 ground electronic state suggests the cold gas is associated with the developing shroud of carbon dust. These absorption lines were not seen at a fainter magnitude on the rise from minimum light nor at maximum light. This is the first detection of cold gas around a RCB star.

  16. A digital map of the high center (HC) and low center (LC) polygon boundaries delineated from high resolution LiDAR data for Barrow, Alaska

    SciTech Connect (OSTI)

    Gangodagamage, Chandana; Wullschleger, Stan

    2014-07-03T23:59:59.000Z

    This dataset represent a map of the high center (HC) and low center (LC) polygon boundaries delineated from high resolution LiDAR data for the arctic coastal plain at Barrow, Alaska. The polygon troughs are considered as the surface expression of the ice-wedges. The troughs are in lower elevations than the interior polygon. The trough widths were initially identified from LiDAR data, and the boundary between two polygons assumed to be located along the lowest elevations on trough widths between them.

  17. A digital map of the high center (HC) and low center (LC) polygon boundaries delineated from high resolution LiDAR data for Barrow, Alaska

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Gangodagamage, Chandana; Wullschleger, Stan

    This dataset represent a map of the high center (HC) and low center (LC) polygon boundaries delineated from high resolution LiDAR data for the arctic coastal plain at Barrow, Alaska. The polygon troughs are considered as the surface expression of the ice-wedges. The troughs are in lower elevations than the interior polygon. The trough widths were initially identified from LiDAR data, and the boundary between two polygons assumed to be located along the lowest elevations on trough widths between them.

  18. agn ii high-resolution: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    in young stellar objects with Spitzer traces disk gas and its response to high energy radiation, but such Ne II emission may also originate in shocks within powerful...

  19. atomic resolution high-angle: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    scattering of electrons CERN Preprints Summary: We consider theoretically the energy loss of electrons scattered to high angles when assuming that the primary beam can be...

  20. High-resolution Soft-RIXS: Scientific Goals and Technical Challenges...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    soft x-ray scattering has been recently boosted mainly by results on high Tc superconductors and other cuprates, where orbital and magnetic excitations could be studied with...

  1. High-resolution three-dimensional imaging of red blood cells parasitized by Plasmodium falciparum and in situ hemozoin crystals using optical diffraction tomography

    E-Print Network [OSTI]

    Kim, Kyoohyun

    We present high-resolution optical tomographic images of human red blood cells (RBC) parasitized by malaria-inducing Plasmodium falciparum (Pf)-RBCs. Three-dimensional (3-D) refractive index (RI) tomograms are reconstructed ...

  2. A Search for Pulsed TeV Gamma-Ray Emission from the Crab Pulsar using the Whipple High Resolution GRANITE III Camera

    E-Print Network [OSTI]

    J. Kildea

    2003-05-29T23:59:59.000Z

    We present the results of a search for pulsed TeV emission from the Crab pulsar using 97 hours of data recorded with the high-resolution GRANITE III camera of the Whipple 10 m gamma-ray telescope.

  3. A Search for Pulsed TeV Gamma-Ray Emission from the Crab Pulsar using the Whipple High Resolution GRANITE III Camera

    E-Print Network [OSTI]

    Kildea, J

    2003-01-01T23:59:59.000Z

    We present the results of a search for pulsed TeV emission from the Crab pulsar using 97 hours of data recorded with the high-resolution GRANITE III camera of the Whipple 10 m gamma-ray telescope.

  4. Time-dependent approach to high-resolution spectroscopy and quantum dynamics of Rydberg atoms in crossed magnetic and electric fields

    E-Print Network [OSTI]

    Tong, Xiao-Min; Chu, Shih-I

    2000-02-01T23:59:59.000Z

    We present a general time-dependent approach for efficient and accurate treatment of high-resolution spectrocopy and quantum dynamics. The procedure is applied to an ab initio time-dependent study of three-dimensional ...

  5. Mexico City Aerosol Analysis During Milagro Using High Resolution Aerosol Mass Spectrometry at the Urban Supersite (T0) - Part 1: Fine Particle Composition and Organic Source Apportionment.

    E-Print Network [OSTI]

    Aiken, A. C.

    Submicron aerosol was analyzed during the MILAGRO field campaign in March 2006 at the T0 urban supersite in Mexico City with a High-Resolution Aerosol Mass Spectrometer (AMS) and complementary instrumentation. Positive ...

  6. A novel apparatus for in situ compression of submicron structures and particles in a high resolution SEM

    SciTech Connect (OSTI)

    Romeis, S.; Paul, J.; Ziener, M.; Peukert, W. [Institute of Particle Technology, University of Erlangen-Nuremberg, Cauerstr. 4, 91058 Erlangen (Germany)

    2012-09-15T23:59:59.000Z

    We report on the development and characterization of a novel in situ manipulation device to perform stressing experiments on the submicron scale inside a high resolution field emission scanning electron microscope. The instrument comprises two main assembly groups: an upper part for positioning and moving a mounted probe and a force sensor as well as a specimen support as lower part. The upper part consists of a closed loop tripod piezoelectric scanner mounted on a self-locking coarse positioning stage. Two interlocked steel springs and a linear variable differential transformer measuring the springs' deflections compose the lower part of the instrument. This arrangement acts as force-sensor and sample support. In comparison to already well-established concepts a wide measuring range is covered by adjusting the spring constant between 30 N/m and 50000 N/m. Moreover, the new device offers striking advantages with respect to force calibration and sample deformation measurements. Force calibration is performed using the eigenfrequency of the force detection system directly inside the SEM. Deformation data are obtained with high accuracy by simultaneously recording displacements above and below the specimen. The detrimental apparatus compliance is determined, and the influence on measured data subsequently minimized: an easy to validate two-springs-in-series model is used for data correction. A force resolution in normal direction of 100 nN accompanied by a sample deformation resolution of 5 nm can be achieved with the instrument using an appropriate load cell stiffness. The capabilities and versatility of this instrument are exemplified by compression experiments performed on submicron amorphous silica particles.

  7. Background and Scattered Light Subtraction in the High-Resolution Echelle Modes of the Space Telescope Imaging Spectrograph

    E-Print Network [OSTI]

    J. Christopher Howk; Kenneth R. Sembach

    1999-12-17T23:59:59.000Z

    We present a simple, effective approach for estimating the on-order backgrounds of spectra taken with the highest-resolution modes of the Space Telescope Imaging Spectrograph (STIS) on-board the Hubble Space Telescope. Our scheme for determining the on-order background spectrum uses polynomial fits to the inter-order scattered light visible in the two-dimensional STIS MAMA images. We present a suite of high-resolution STIS spectra to demonstrate that our background subtraction routine produces the correct overall zero point, as judged by the small residual flux levels in the centers of strongly-saturated interstellar absorption lines. Although there are multiple sources of background light in STIS echelle mode data, this simple approach works very well for wavelengths longward of Lyman-alpha. At shorter wavelengths, the smaller order separation and generally lower signal-to-noise ratios of the data can reduce the effectiveness of our background estimation procedure. Slight artifacts in the background-subtracted spectrum can be seen in some cases, particularly at wavelengths <1300 Ang. Most of these are caused by echelle scattering of strong spectral features into the inter-order light. We discuss the limitations of high-resolution STIS data in light of the uncertainties associated with our background subtraction procedure. We compare our background-subtracted STIS spectra with GHRS Ech-A observations of the DA white dwarf G191-B2B and GHRS first-order G160M observations of the early-type star HD 218915. We find no significant differences between the GHRS data and the STIS data reduced with our method in either case.

  8. A Very High Spectral Resolution Study of Ground-State OH Masers in W3(OH)

    E-Print Network [OSTI]

    Vincent L. Fish; Walter F. Brisken; Loránt O. Sjouwerman

    2006-04-25T23:59:59.000Z

    We present VLBA observations of the ground-state hydroxyl masers in W3(OH) at 0.02 km s-1 spectral resolution. Over 250 masers are detected, including 56 Zeeman pairs. Lineshapes are predominantly Gaussian or combinations of several Gaussians, with normalized deviations typically of the same magnitude as in masers in other species. Typical FWHM maser linewidths are 0.15 to 0.38 km s-1 and are larger in the 1665 MHz transition than in the other three ground-state transitions. The satellite-line 1612 and 1720 MHz masers show no evidence of sigma^+/-2,3 components. The spatial positions of most masers are seen to vary across the line profile, with many spots showing clear, organized positional gradients. Equivalent line-of-sight velocity gradients in the plane of the sky typically range from 0.01 to 1 km s-1 AU-1 (i.e., positional gradients of 1 to 100 AU (km s-1)-1). Small velocity gradients in the 1667 MHz transition support theoretical predictions that 1667 MHz masers appear in regions with small velocity shifts along the amplification length. Deconvolved maser spot sizes appear to be larger in the line wings but do not support a spherical maser geometry.

  9. The Dynamics of Sinking Satellites Around Disk Galaxies: A Poor Man's Alternative to High-Resolution Numerical Simulations

    E-Print Network [OSTI]

    J. E. Taylor; Arif Babul

    2000-12-14T23:59:59.000Z

    We have developed a simple yet surprisingly accurate analytic scheme for tracking the dynamical evolution of substructure within larger dark halos. The scheme incorporates the effects of dynamical friction, tidal mass loss and tidal heating via physically motivated approximations. Using our scheme, we can predict the orbital evolution and mass-loss history of individual subhalos in detail. We are also able to determine the impact and importance of the different physical processes on the dynamical evolution of the subhalos. To test and calibrate this model, we compare it with a set of recent high-resolution numerical simulations of mergers between galaxies and small companions. We find that we can reproduce the orbits and mass-loss rates seen in all of these simulations with considerable accuracy, using a single set of values for the three free parameters in our model. Computationally, our scheme is more than 1000 times faster than the simplest of the high-resolution numerical simulations. This means that we can carry out detailed and statistically meaningful investigations into the characteristics of the subhalo population in different cosmologies, the stripping and disruption of the subhalos, and the interactions of the subhalos with other dynamical structures such as a thin disk. This last point is of particular interest given the ubiquity of minor mergers in hierarchical models. In this regard, our method's simplicity and speed makes it particularly attractive for incorporation into semi-analytic models of galaxy formation.

  10. The SEGUE Stellar Parameter Pipeline. III. Comparison with High-Resolution Spectroscopy of SDSS/SEGUE Field Stars

    E-Print Network [OSTI]

    C. Allende Prieto; T. Sivarani; T. C. Beers; Y. S. Lee; L. Koesterke; M. Shetrone; C. Sneden; D. L. Lambert; R. Wilhelm; C. M. Rockosi; D. Lai; B. Yanny; I. I. Ivans; J. A. Johnson; W. Aoki; C. A. L. Bailer-Jones; P. Re Fiorentin

    2007-10-31T23:59:59.000Z

    We report high-resolution spectroscopy of 125 field stars previously observed as part of the Sloan Digital Sky Survey and its program for Galactic studies, the Sloan Extension for Galactic Understanding and Exploration (SEGUE). These spectra are used to measure radial velocities and to derive atmospheric parameters, which we compare with those reported by the SEGUE Stellar Parameter Pipeline (SSPP). The SSPP obtains estimates of these quantities based on SDSS ugriz photometry and low-resolution (R = 2000) spectroscopy. For F- and G-type stars observed with high signal-to-noise ratios (S/N), we empirically determine the typical random uncertainties in the radial velocities, effective temperatures, surface gravities, and metallicities delivered by the SSPP to be 2.4 km/s, 130 K (2.2%), 0.21 dex, and 0.11 dex, respectively, with systematic uncertainties of a similar magnitude in the effective temperatures and metallicities. We estimate random errors for lower S/N spectra based on numerical simulations.

  11. HIGH-RESOLUTION HELIOSEISMIC IMAGING OF SUBSURFACE STRUCTURES AND FLOWS OF A SOLAR ACTIVE REGION OBSERVED BY HINODE

    SciTech Connect (OSTI)

    Zhao Junwei; Kosovichev, Alexander G. [W. W. Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305-4085 (United States); Sekii, Takashi [National Astronomical Observatory of Japan, 2-21-1 Osawa, Mitaka, Tokyo 181-8588 (Japan)

    2010-01-01T23:59:59.000Z

    We analyze a solar active region observed by the Hinode Ca II H line using the time-distance helioseismology technique, and infer wave-speed perturbation structures and flow fields beneath the active region with a high spatial resolution. The general subsurface wave-speed structure is similar to the previous results obtained from Solar and Heliospheric Observatory/Michelson Doppler Imager observations. The general subsurface flow structure is also similar, and the downward flows beneath the sunspot and the mass circulations around the sunspot are clearly resolved. Below the sunspot, some organized divergent flow cells are observed, and these structures may indicate the existence of mesoscale convective motions. Near the light bridge inside the sunspot, hotter plasma is found beneath, and flows divergent from this area are observed. The Hinode data also allow us to investigate potential uncertainties caused by the use of phase-speed filter for short travel distances. Comparing the measurements with and without the phase-speed filtering, we find out that inside the sunspot, mean acoustic travel times are in basic agreement, but the values are underestimated by a factor of 20%-40% inside the sunspot umbra for measurements with the filtering. The initial acoustic tomography results from Hinode show a great potential of using high-resolution observations for probing the internal structure and dynamics of sunspots.

  12. High-resolution imaging of latch-up sites in CMOS IC

    E-Print Network [OSTI]

    Shah, Mayank

    1993-01-01T23:59:59.000Z

    in well. This P value is still too high to eliminate latch-up susceptibility. In a P-well or twin-tub technology forming a vertical NPN parasitic transistor, the P value is even higher because of the higher mobility of the minority carriers in the base... by this electron beam technique is highly sensitive to even a small electric field. The voltage applied to the device is an alternating signal with high frequency synchronized with a multiple of the SEM line scan rate. Comparing an image of a unlatched circuit...

  13. Geoacoustic inversion in laterally varying shallow-water experiments using high-resolution wavenumber estimation

    E-Print Network [OSTI]

    Becker, Kyle M

    2002-01-01T23:59:59.000Z

    Sound propagation in shallow water is highly dependent on the interaction of the sound field with the bottom. In order to fully understand this problem, it is necessary to obtain reliable estimates of bottom geoacoustic ...

  14. High resolution reanalysis of wind speeds over the British Isles for wind energy integration 

    E-Print Network [OSTI]

    Hawkins, Samuel Lennon

    2012-11-29T23:59:59.000Z

    The UK has highly ambitious targets for wind development, particularly offshore, where over 30GW of capacity is proposed for development. Integrating such a large amount of variable generation presents enormous challenges. ...

  15. High-Resolution Mapping of the Spatial Organization of a Bacterial Chromosome

    E-Print Network [OSTI]

    Le, Tung Ba Khanh

    Chromosomes must be highly compacted and organized within cells, but how this is achieved in vivo remains poorly understood. We report the use of chromosome conformation capture coupled with deep sequencing (Hi-C) to map ...

  16. adaptive high-resolution simulation: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    observed in M87. The beam is surrounded by a boundary layer of high specific internal energy. The properties of this layer are briefly discussed. M. A. Aloy; J. M. Ibanez; J. M....

  17. Thin optic surface analysis for high resolution X-ray telescopes

    E-Print Network [OSTI]

    Akilian, Mireille

    2004-01-01T23:59:59.000Z

    The art of glass developed throughout the years has covered artifacts ranging from crude ornaments to high precision optics used in flat panel displays, hard disk drives, and x-ray telescopes. Methods for manufacturing ...

  18. Final Technical Report for DE-FG02-06ER15835: Chemical Imaging with 100nm Spatial Resolution: Combining High Resolution Flurosecence Microscopy and Ion Mobility Mass Spectrometry

    SciTech Connect (OSTI)

    Buratto, Steven K. [UC Santa Barbara

    2013-09-03T23:59:59.000Z

    We have combined, in a single instrument, high spatial resolution optical microscopy with the chemical specificity and conformational selectivity of ion mobility mass spectrometry. We discuss the design and construction of this apparatus as well as our efforts in applying this technique to thin films of molecular semiconductor materials.

  19. The High Resolution Fly's Eye ( HiRes ) Project D.J. Bird,1

    E-Print Network [OSTI]

    Australia 4 High Energy Astrophysics Institute, Department of Physics, U. of Utah, Salt Lake City, UT 84112 to the measurement of cosmic rays in this energy range: large ground arrays ( Area > 100 km2 ), and the Nitrogen USA ABSTRACT At the present time, the origin of cosmic rays in the EH E region ( Energy > 1018 e

  20. Digital Image Processing "Cookbook": A method to derive bathymetric data from high spatial resolution multi-

    E-Print Network [OSTI]

    Wright, Dawn Jeannine

    Digital Image Processing "Cookbook": A method to derive bathymetric data from high spatial;Processing Method: Overview 1) Viewing of Images Software: ENVI, ArcGIS 2) Data Conversion from DN (digital by step outline, with comments concerning processing methods and accuracy issues, for a methodology

  1. HRENSEMBLEHR High Resolution Ensemble for Horns Rev: A project overview Mhrlen, C.1

    E-Print Network [OSTI]

    of large wind farms change between nearly constant output to highly variable power output. A balance benefits of offshore wind power is a smoothing effect on the energy price, because it has it's own of 14GW wind power in the Northsea. For this purpose an algorithm based on ensemble predictions

  2. High resolution low-temperature superconductivity superconducting quantum interference device microscope for imaging magnetic fields

    E-Print Network [OSTI]

    Weiss, Benjamin P.

    -temperature superconducting niobium wire coupled to the input circuit of a superconducting quantum interference device SQUID-stated advantages of high-temperature superconductivity HTS over the more advanced low- temperature superconductivity LTS is that the higher oper- ating temperature, typically around 77 K, allows HTS SQUIDs

  3. High resolution InSb quantum well ballistic nanosensors for room temperature applications

    SciTech Connect (OSTI)

    Gilbertson, Adam; Cohen, L. F. [Blackett Laboratory, Imperial College London, SW7 2BZ (United Kingdom); Lambert, C. J. [Department of Physics, Lancaster University, Lancaster, LA1 4YB (United Kingdom); Solin, S. A. [Department of Physics, Washington University in St. Louis, St. Louis, Missouri 63130 (United States)

    2013-12-04T23:59:59.000Z

    We report the room temperature operation of a quasi-ballistic InSb quantum well Hall sensor that exhibits a high frequency sensitivity of 560nT/?Hz at 20uA bias current. The device utilizes a partitioned buffer layer design that suppresses leakage currents through the mesa floor and can sustain large current densities.

  4. High-Resolution Electrospray Ionization Mass Spectrometry Analysis of Water- Soluble Organic Aerosols Collected with a Particle into Liquid Sampler

    SciTech Connect (OSTI)

    Bateman, Adam P.; Nizkorodov, Serguei; Laskin, Julia; Laskin, Alexander

    2010-10-01T23:59:59.000Z

    This work demonstrates the utility of a particle-into-liquid sampler (PILS) a technique traditionally used for identification of inorganic ions present in ambient or laboratory aerosols for the analysis of water soluble organic aerosol (OA) using high resolution electrospray ionization mass spectrometry (HR ESI-MS). Secondary organic aerosol (SOA) was produced from 0.5 ppm mixing ratios of limonene and ozone in a 5 m3 Teflon chamber. SOA was collected simultaneously using a traditional filter sampler and a PILS. The filter samples were later extracted with either water or acetonitrile, while the aqueous PILS samples were analyzed directly. In terms of peak intensities, types of detectable compounds, average O:C ratios, and organic mass to organic carbon ratios, the resulting high resolution mass spectra were essentially identical for the PILS and filter based samples. SOA compounds extracted from both filter/acetonitrile extraction and PILS/water extraction accounted for >95% of the total ion current in ESI mass spectra. This similarity was attributed to high solubility of limonene SOA in water. In contrast, significant differences in detected ions and peak abundances were observed for pine needle biomass burning organic aerosol (BBOA) collected with PILS and filter sampling. The water soluble fraction of BBOA is considerably smaller than for SOA, and a number of unique peaks were detectable only by the filter/acetonitrile method. The combination of PILS collection with HR-ESI-MS analysis offers a new approach for molecular analysis of the water-soluble organic fraction in biogenic SOA, aged photochemical smog, and BBOA.

  5. Short range micro-power impulse radar with high resolution swept range gate with damped transmit and receive cavities

    DOE Patents [OSTI]

    McEwan, T.E.

    1998-06-30T23:59:59.000Z

    A radar range finder and hidden object locator is based on ultra-wide band radar with a high resolution swept range gate. The device generates an equivalent time amplitude scan with atypical range of 4 inches to 20 feet, and an analog range resolution as limited by a jitter of on the order of 0.01 inches. A differential sampling receiver is employed to effectively eliminate ringing and other aberrations induced in the receiver by the near proximity of the transmit antenna, so a background subtraction is not needed, simplifying the circuitry while improving performance. Uses of the invention include a replacement of ultrasound devices for fluid level sensing, automotive radar, such as cruise control and parking assistance, hidden object location, such as stud and rebar finding. Also, this technology can be used when positioned over a highway lane to collect vehicle count and speed data for traffic control. Techniques are used to reduce clutter in the receive signal, such as decoupling the receive and transmit cavities by placing a space between them, using conductive or radiative damping elements on the cavities, and using terminating plates on the sides of the openings. 20 figs.

  6. Experiments with the High Resolution Kaon Spectrometer at Jlab Hall C and the New Spectroscopy of ^12_Lambda B Hypernuclei

    SciTech Connect (OSTI)

    Tang, Liguang; Chen, Chunhua; Gogami, Toshiyuki; Kawama, Daisuke; Han, Yuncheng; Yuan, Lulin; Matsumura, Akihiko; Okayasu, Yuichi; Seva, Tomislav; Rodriguez, Victor; Baturin, Pavlo; Acha Quimper, Armando; Achenbach, Carsten; Ahmidouch, Abdellah; Albayrak, Ibrahim; Androic, Darko; Asaturyan, Arshak; Asaturyan, Razmik; Ates, Ozgur; Badui, Rafael; Baker, Oliver; Benmokhtar, Fatiha; Boeglin, Werner; Bono, Jason; Bosted, Peter; Brash, Edward; Carter, Philip; Carlini, Roger; Chiba, Atsushi; Christy, Michael; Cole, Leon; Dalton, Mark; Danagoulian, Samuel; Daniel, Aji; De Leo, Raffaele; Dharmawardane, Kahanawita; Doi, Daisuke; Egiyan, Kim; Elaasar, Mostafa; Ent, Rolf; Fenker, Howard; Fujii, Yu; Furic, Miroslav; Gabrielyan, Marianna; Gan, Liping; Garibaldi, Franco; Gaskell, David; Gasparian, Ashot; Gibson, Edward; Gueye, Paul; Hashimoto, Osamu; Honda, D.; Horn, Tanja; Hu, Bitao; Hungerford, Ed; Jayalath, Chandana; Jones, Mark; Johnston, Kathleen; Kalantarians, Narbe; Kanda, Hiroki; Kaneta, M.; Kato, F.; Kato, Seigo; Kawai, Masaharu; Keppel, Cynthia; Khanal, Hari; Kohl, M.; Kramer, Laird; Lan, Kejian; Li, Ya; Habarakada Liyanage, Anusha; Luo, Wei; Mack, David; Maeda, Kazushige; Malace, Simona; Margaryan, Amur; Marikyan, Gagik; Markowitz, Pete; Maruta, Tomofumi; Maruyama, Nayuta; Maxwell, Victor; Millener, David; Miyoshi, Toshinobu; Mkrtchyan, Arthur; Mkrtchyan, Hamlet; Motoba, Toshio; Nagao, Sho; Nakamura, Satoshi; Narayan, Amrendra; Neville, Casey; Niculescu, Gabriel; Niculescu, Maria; Nunez, Angel; Nuruzzaman, nfn; Nomura, Hiroshi; Nonaka, Kenichi; Ohtani, Atsushi; Oyamada, Masamichi; Perez, Naipy; Petkovic, Tomislav; Pochodzalla, J.; Qiu, Xiyu; Randeniya, Kapugodage; Raue, Brian; Reinhold, Joerg; Rivera, R.; Roche, Julie; Samanta, Chhanda; Sato, Yoshinori; Sawatzky, Bradley; Segbefia, Edwin; Schott, Diane; Shichijo, Ayako; Simicevic, Neven; Smith, Gregory; Song, Yushou; Sumihama, Mizuki; Tadevosyan, Vardan; Takahashi, Toshiyuki; Taniya, Naotaka; Tsukada, Kyo; Tvaskis, Vladas; Veilleux, Micah; Vulcan, William; Wells, Steven; Wesselmann, Frank; Wood, Stephen; Yamamoto, Taku; Yan, Chen; Ye, Z.; Yokota, Kosuke; Zhamkochyan, Simon; Zhu, Lingyan

    2014-09-01T23:59:59.000Z

    Since the pioneering experiment, E89-009 studying hypernuclear spectroscopy using the $(e,e^{\\prime}K^+)$ reaction was completed, two additional experiments, E01-011 and E05-115, were performed at Jefferson Lab. These later experiments used a modified experimental design, the "Tilt Method", to dramatically suppress the large electromagnetic background, and allowed for a substantial increase in luminosity. Additionally, a new kaon spectrometer, HKS (E01-011), a new electron spectrometer, HES, and a new splitting magnet were added to produce precision, high-resolution hypernuclear spectroscopy. These two experiments, E01-011 and E05-115, resulted in two new data sets, producing sub-MeV energy resolution in the spectra of ${}^{7}_{\\Lambda}\\text{He}$, ${}^{12}_{\\Lambda}\\text{B}$ and ${}^{28}_{\\Lambda} \\text{Al}$ and ${}^{7}_{\\Lambda}\\text{He}$, ${}^{10}_{\\Lambda}\\text{Be}$, ${}^{12}_{\\Lambda}\\text{B}$ and ${}^{52}_{\\Lambda}\\text{V}$. All three experiments obtained a ${}^{12}_{\\Lambda}\\text{B}$, spectrum, which is the most characteristic $p$-shell hypernucleus and is commonly used for calibration. Independent analyses of these different experiments demonstrate excellent consistency and provide the clearest level structure to date of this hypernucleus as produced by the $(e,e^{\\prime}K^+)$ reaction. This paper presents details of these experiments, and the extraction and analysis of the observed ${}^{12}_{\\Lambda}\\text{B}$ spectrum.

  7. The Ultraviolet Emission Properties of Five Low-Redshift Active Galactic Nuclei at High Signal to Noise and Spectral Resolution

    E-Print Network [OSTI]

    Ari Laor; John N. Bahcall; Buell T. Jannuzi; Donald P. Schneider; Richard F. Green; George F. Hartig

    1993-05-21T23:59:59.000Z

    We analyze the ultraviolet (UV) emission line and continuum properties of five low-redshift active galactic nuclei (four luminous quasars: PKS~0405$-$123, H1821+643, PG~0953+414, and 3C273, and one bright Seyfert 1 galaxy: Mrk~205). The HST spectra have higher signal-to-noise ratios (typically $\\sim 60$ per resolution element) and spectral resolution ($R = 1300$) than all previously- published UV spectra used to study the emission characteristics of active galactic nuclei. We include in the analysis ground-based optical spectra covering \\hb\\ and the narrow [O III] $\\lambda\\lambda$4959,5007 doublet. The following new results are obtained: \\lyb/\\lya=0.03$-$0.12 for the four quasars, which is the first accurate measurement of the long-predicted \\lyb\\ intensity in QSOs. The cores of \\lya\\ and C~IV are symmetric to an accuracy of better than 2.5% within about 2000 km s$^{-1}$ of the line peak. This high degree of symmetry of \\lya\\ argues against models in which the broad line cloud velocity field has a significant radial component. The observed smoothness of the \\lya\\ and C~IV line profiles requires at least $\\sim 10^4$ individual clouds if bulk velocity is the only line-broadening mechanism. The overall similarity of the \\lya\\ and C IV $\\lambda$1549 profiles rules out models for the broad line region (BLR) with a radial distribution of virialized....

  8. Short range micro-power impulse radar with high resolution swept range gate with damped transmit and receive cavities

    DOE Patents [OSTI]

    McEwan, Thomas E. (Livermore, CA)

    1998-01-01T23:59:59.000Z

    A radar range finder and hidden object locator is based on ultra-wide band radar with a high resolution swept range gate. The device generates an equivalent time amplitude scan with atypical range of 4 inches to 20 feet, and an analog range resolution as limited by a jitter of on the order of 0.01 inches. A differential sampling receiver is employed to effectively eliminate ringing and other aberrations induced in the receiver by the near proximity of the transmit antenna, so a background subtraction is not needed, simplifying the circuitry while improving performance. Uses of the invention include a replacement of ultrasound devices for fluid level sensing, automotive radar, such as cruise control and parking assistance, hidden object location, such as stud and rebar finding. Also, this technology can be used when positioned over a highway lane to collect vehicle count and speed data for traffic control. Techniques are used to reduce clutter in the receive signal, such as decoupling the receive and transmit cavities by placing a space between them, using conductive or radiative damping elements on the cavities, and using terminating plates on the sides of the openings.

  9. High-resolution truncated plurigaussian simulations for the characterization of heterogeneous formations

    E-Print Network [OSTI]

    Mariethoz, Grégroire; Cornaton, Fabien; Jaquet, Olivier; 10.1111/j.1745-6584.2008.00489.x

    2011-01-01T23:59:59.000Z

    Integrating geological concepts, such as relative positions and proportions of the different lithofacies, is of highest importance in order to render realistic geological patterns. The truncated plurigaussian simulation method provides a way of using both local and conceptual geological information to infer the distributions of the facies and then those of hydraulic parameters. The method (Le Loc'h and Galli 1994) is based on the idea of truncating at least two underlying multi-Gaussian simulations in order to create maps of categorical variable. In this manuscript we show how this technique can be used to assess contaminant migration in highly heterogeneous media. We illustrate its application on the biggest contaminated site of Switzerland. It consists of a contaminant plume located in the lower fresh water Molasse on the western Swiss Plateau. The highly heterogeneous character of this formation calls for efficient stochastic methods in order to characterize transport processes.

  10. A High Resolution Hydrometer Phase Classifier Based on Analysis of Cloud Radar Doppler Spectra.

    SciTech Connect (OSTI)

    Luke,E.; Kollias, P.

    2007-08-06T23:59:59.000Z

    The lifecycle and radiative properties of clouds are highly sensitive to the phase of their hydrometeors (i.e., liquid or ice). Knowledge of cloud phase is essential for specifying the optical properties of clouds, or else, large errors can be introduced in the calculation of the cloud radiative fluxes. Current parameterizations of cloud water partition in liquid and ice based on temperature are characterized by large uncertainty (Curry et al., 1996; Hobbs and Rangno, 1998; Intriery et al., 2002). This is particularly important in high geographical latitudes and temperature ranges where both liquid droplets and ice crystal phases can exist (mixed-phase cloud). The mixture of phases has a large effect on cloud radiative properties, and the parameterization of mixed-phase clouds has a large impact on climate simulations (e.g., Gregory and Morris, 1996). Furthermore, the presence of both ice and liquid affects the macroscopic properties of clouds, including their propensity to precipitate. Despite their importance, mixed-phase clouds are severely understudied compared to the arguably simpler single-phase clouds. In-situ measurements in mixed-phase clouds are hindered due to aircraft icing, difficulties distinguishing hydrometeor phase, and discrepancies in methods for deriving physical quantities (Wendisch et al. 1996, Lawson et al. 2001). Satellite-based retrievals of cloud phase in high latitudes are often hindered by the highly reflecting ice-covered ground and persistent temperature inversions. From the ground, the retrieval of mixed-phase cloud properties has been the subject of extensive research over the past 20 years using polarization lidars (e.g., Sassen et al. 1990), dual radar wavelengths (e.g., Gosset and Sauvageot 1992; Sekelsky and McIntosh, 1996), and recently radar Doppler spectra (Shupe et al. 2004). Millimeter-wavelength radars have substantially improved our ability to observe non-precipitating clouds (Kollias et al., 2007) due to their excellent sensitivity that enables the detection of thin cloud layers and their ability to penetrate several non-precipitating cloud layers. However, in mixed-phase clouds conditions, the observed Doppler moments are dominated by the highly reflecting ice crystals and thus can not be used to identify the cloud phase. This limits our ability to identify the spatial distribution of cloud phase and our ability to identify the conditions under which mixed-phase clouds form.

  11. Combined Borehole Seismic and Electromagnetic Inversion For High-Resolution Petrophysical Assessment Of Hydocarbon Reservoirs

    SciTech Connect (OSTI)

    Carlos Torres-Verdin; G. Michael Hoversten; Ki Ha Lee; Gregory Newman; Kurt Nihei

    2008-12-31T23:59:59.000Z

    This report summarizes the work performed between January 2005 and December 2007, under DOE research contract DE-FC26-04NT15507. The project is was performed by the Center for Petroleum and Geosystems Engineering of The University of Texas at Austin and Lawrence Berkeley National Laboratory under the auspices of the National Energy Technology Office (NETL) and the Strategic Center for Natural Gas and Oil (SCNGO). During the three-year project, we developed new methods to combine borehole sonic and electromagnetic (EM) measurements for the improved assessment of elastic and petrophysical properties of rock formations penetrated by a well. Sonic measurements consisted of full waveform acoustic amplitudes acquired with monopole and dipole sources, whereas EM measurements consisted of frequency-domain voltages acquired with multi-coil induction systems. The combination of sonic and EM measurements permitted the joint estimation of elastic and petrophysical properties in the presence of mud-filtrate invasion. It was conclusively shown that the combined interpretation of sonic and EM measurements reduced non-uniqueness in the estimation of elastic and petrophysical properties and improved the spatial resolution of the estimations compared to estimations yielded separately from the two types of measurements. Moreover, this approach enabled the assessment of dynamic petrophysical properties such as permeability, as it incorporated the physics of mud-filtrate invasion in the interpretation of the measurements. The first part of the project considered the development of fast and reliable numerical algorithms to simulate borehole sonic waveforms in 2D, 3D, and radial 1D media. Such algorithms were subsequently used in the quantitative estimation of elastic properties jointly from borehole sonic and EM measurements. In the second part of the project we developed a new algorithm to estimate water saturation, porosity, and dry-rock elastic moduli jointly from borehole sonic and EM measurements. This algorithm assumed radial 1D variations of fluid saturation due to mud-filtrate invasion. Subsequently, we adapted the estimation method to interpret borehole field measurements acquired in both a shaly-sand sedimentary sequence and a tight-gas sandstone formation. In the two cases, we simulated the process of mud-filtrate invasion and concomitantly honored sonic and EM measurements. We produced reliable estimates of permeability and dry-rock moduli that were successfully validated with rock-core measurements. Finally, we introduced a new stochastic inversion procedure to estimate elastic, electrical, and petrophysical properties of layered media jointly from waveform sonic and frequency-domain EM measurements. The procedure was based on Bayesian statistical inversion and delivered estimates of uncertainty under various forms of a-priori information about the unknown properties. Tests on realistic synthetic models confirmed the reliability of this procedure to estimate elastic and petrophysical properties jointly from sonic and EM measurements. Several extended abstracts and conference presentations stemmed from this project, including 2 SEG extended abstracts, 1 SPE extended abstract, and 2 SPWLA extended abstracts. Some of these extended abstracts have been submitted for publication in peer-reviewed journals.

  12. High-resolution, high-transmission soft x-ray spectrometer for the study of biological samples

    SciTech Connect (OSTI)

    Fuchs, Oliver; Weinhardt, L.; Blum, M.; Weigand, M.; Umbach, E.; Bar, M.; Heske, Clemens; Denlinger, Jonathan; Chuang, Y.-D.; McKinney, Wayne; Hussain, Zahid; Gullikson, Eric; Jones, M.; Batson, Phil; Nelles, B.; Follath, R.

    2009-03-09T23:59:59.000Z

    We present a variable line-space grating spectrometer for soft x-rays that covers the photon energy range between 130 and 650 eV. The optical design is based on the Hettrick-Underwood principle and tailored to synchrotron-based studies of radiation-sensitive biological samples. The spectrometer is able to record the entire spectral range in one shot, i.e., without any mechanical motion, at a resolving power of 1200 or better. Despite its slitless design, such a resolving power can be achieved for a source spot as large as 30x3000 mu m2, which is important for keeping beam damage effects in radiation-sensitive samples low. The high spectrometer efficiency allows recording of comprehensive two-dimensional resonant inelastic soft x-ray scattering (RIXS) maps with good statistics within several minutes. This is exemplarily demonstrated for a RIXS map of highly oriented pyrolytic graphite, which was taken within 10 min.

  13. High resolution imaging with Fresnel interferometric arrays: suitability for exoplanet detection

    E-Print Network [OSTI]

    L. Koechlin; D. Serre; P. Duchon

    2005-10-13T23:59:59.000Z

    We propose a new kind of interferometric array that yields images of high dynamic range and large field. The numerous individual apertures in this array form a pattern related to a Fresnel zone plate. This array can be used for astrophysical imaging over a broad spectral bandwidth spanning from the U.V. (50 nanometers) to the I.R. (20 microns). Due to the long focal lengths involved, this instrument requires formation-flying of two space borne vessels. We present the concept and study the S/N ratio in different situations, then apply these results to probe the suitability of this concept to detect exoplanets.

  14. LA-ICP-AES using a high resolution fiber optic interferometer | The Ames

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville PowerCherries 82981-1cnHigh SchoolIn12electron beamJoin2015JustKateKent52P6.02Laboratory

  15. High Resolution Structure of the Neisseria gonorrhoeae Type IV Pilus: A

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville PowerCherries 82981-1cn SunnybankD.jpgHanfordDepartmentInnovationHighMembrane-bound Fibrous

  16. Vibronic fine structure in high-resolution x-ray absorption spectra from ion-bombarded boron nitride nanotubes

    SciTech Connect (OSTI)

    Petravic, Mladen; Peter, Robert; Varasanec, Marijana [Department of Physics and Center for Micro and Nano Sciences and Technologies, University of Rijeka, 51000 Rijeka (Croatia); Li Luhua; Chen Ying [Institute for Technology Research and Innovation, Deakin University, Geelong Waurn Ponds Campus, 3217 (Australia); Cowie, Bruce C. C. [Australian Synchrotron, Clayton VIC 3168 (Australia)

    2013-05-15T23:59:59.000Z

    The authors have applied high-resolution near-edge x-ray absorption fine structure measurements around the nitrogen K-edge to study the effects of ion-bombardment on near-surface properties of boron nitride nanotubes. A notable difference has been observed between surface sensitive partial electron yield (PEY) and bulk sensitive total electron yield (TEY) fine-structure measurements. The authors assign the PEY fine structure to the coupling of excited molecular vibrational modes to electronic transitions in NO molecules trapped just below the surface. Oxidation resistance of the boron nitride nanotubes is significantly reduced by low energy ion bombardment, as broken B-N bonds are replaced by N-O bonds involving oxygen present in the surface region. In contrast to the PEY spectra, the bulk sensitive TEY measurements on as-grown samples do not exhibit any fine structure while the ion-bombarded samples show a clear vibronic signature of molecular nitrogen.

  17. Simplified models of stellar wind anatomy to interpret high-resolution data: Analytical approach to embedded spiral geometries

    E-Print Network [OSTI]

    Homan, Ward; de Koter, Alex; van Marle, Allard Jan; Lombaert, Robin; Vlemmings, Wouter

    2015-01-01T23:59:59.000Z

    Recent high-resolution observations have shown stellar winds to harbour complexities which strongly deviate from spherical symmetry, generally assumed as standard wind model. One such morphology is the archimedean spiral, generally believed to be formed by binary interactions, which has been directly observed in multiple sources. We seek to investigate the manifestation in the observables of spiral structures embedded in the spherical outflows of cool stars. We aim to provide an intuitive bedrock with which upcoming ALMA data can be compared and interpreted. By means of an extended parameter study, we model rotational CO emission from the stellar outflow of asymptotic giant branch stars. To this end, we develop a simplified analytical parametrised description of a 3D spiral structure. This model is embedded into a spherical wind, and fed into the 3D radiative transfer code LIME, which produces 3D intensity maps throughout velocity space. Subsequently, we investigate the spectral signature of rotational transi...

  18. High Spatial Resolution KAO Far-Infrared Observations of the Central Regions of Infrared-Bright Galaxies

    E-Print Network [OSTI]

    Beverly J. Smith; P. M. Harvey

    1996-05-06T23:59:59.000Z

    We present new high spatial resolution Kuiper Airborne Observatory 50 micron and/or 100 micron data for 11 infrared-bright galaxies. We also tabulate previously published KAO data for 11 other galaxies, along with the IRAS data for the bulges of M 31 and M 81. We find that L(FIR)/L(B) and L(FIR)/L(H) correlate with CO (1 - 0) intensity and tau(100). Galaxies with optical or near-infrared signatures of OB stars in their central regions have higher values of I(CO) and tau(100), as well as higher far-infrared surface brightnesses and L(FIR)/L(B) and L(FIR)/L(H) ratios. L(FIR)/L(H(alpha)) does not correlate strongly with CO and tau(100). These results support a scenario in which OB stars dominate dust heating in the more active galaxies and older stars are important in quiescent bulges.

  19. Time-Resolved Molecular Characterization of Limonene/Ozone Aerosol using High-Resolution Electrospray Ionization Mass Spectrometry

    SciTech Connect (OSTI)

    Bateman, Adam P.; Nizkorodov, Serguei; Laskin, Julia; Laskin, Alexander

    2009-09-09T23:59:59.000Z

    Molecular composition of limonene/O3 secondary organic aerosol (SOA) was investigated using high-resolution electrospray ionization mass spectrometry (HR-ESI-MS) as a function of reaction time. SOA was generated by ozonation of D-limonene in a reaction chamber and sampled at different time intervals using a cascade impactor. The SOA samples were extracted into acetonitrile and analyzed using a HR-ESI-MS instrument with a resolving power of 100,000 (m/?m). The resulting mass spectra provided detailed information about the extent of oxidation inferred from the O:C ratios, double bond equivalency (DBE) factors, and aromaticity indexes (AI) in hundreds of identified individual SOA species.

  20. A High Spectral Resolution Atlas of Comet 122P/de Vico

    E-Print Network [OSTI]

    Anita L. Cochran; William D. Cochran

    2002-02-01T23:59:59.000Z

    On 3 and 4 October, 1995, we obtained high spectral resolving power (R=\\lambda/\\Delta\\lambda = 60,000) observations of comet 122P/de Vico using the 2DCoude cross-dispersed echelle spectrograph on the 2.7-m telescope of McDonald Observatory. The spectra cover the wavelength range from 3830A--10192A. The spectra from 3830--5776A are continuous; from 5777--10192A there are increasing interorder gaps. The comet was at a heliocentric distance of 0.66au and a geocentric distance of 1.0au. Comet de Vico has a very high gas-to-dust ratio and the spectra have excellent signal/noise. These two factors combined to yield spectra with a large number of emission lines. We have collected laboratory molecular line lists and have used these line lists in order to identify as many of the detected lines as possible. We have identified 12,219 emission lines and have located another 4,055 lines which we cannot identify. We present representative spectra and identifications along with a description of our plans to make these spectra and identifications available to the community. This atlas should prove a valuable tool for future studies of comets.