National Library of Energy BETA

Sample records for high occupancy toll

  1. An examination of factors affecting high occupancy/toll lane demand 

    E-Print Network [OSTI]

    Appiah, Justice

    2004-11-15

    eastbound between 4:00 p.m. and 6:00 p.m., Monday through Friday. Customers pay their toll from prepaid accounts using a FasTrak transponder (a portable radio transmission device attached to the windshield). The Express Lanes facility provides average...

  2. A Feedback-Based Dynamic Tolling Algorithm for High Occupancy Toll (HOT) Lane Operations

    E-Print Network [OSTI]

    Washington at Seattle, University of

    , including lost time, wasted energy, excess air pollution, and lost productivity. The 2005 Urban Mobility operations can realize the optimal traffic allocation and enhance overall infrastructure efficiency. However from congestion in the 85 surveyed-urban areas in 2003 (1). It is of practical importance to manage

  3. A Review of High Occupancy Vehicle (HOV) Lane Performance and...

    Open Energy Info (EERE)

    A Review of High Occupancy Vehicle (HOV) Lane Performance and Policy Options in the United States: Final Report Jump to: navigation, search Tool Summary LAUNCH TOOL Name: A Review...

  4. Occupational Safety Review of High Technology Facilities

    SciTech Connect (OSTI)

    Lee Cadwallader

    2005-01-31

    This report contains reviews of operating experiences, selected accident events, and industrial safety performance indicators that document the performance of the major US DOE magnetic fusion experiments and particle accelerators. These data are useful to form a basis for the occupational safety level at matured research facilities with known sets of safety rules and regulations. Some of the issues discussed are radiation safety, electromagnetic energy exposure events, and some of the more widespread issues of working at height, equipment fires, confined space work, electrical work, and other industrial hazards. Nuclear power plant industrial safety data are also included for comparison.

  5. Potential shift from transit to single occupancy vehicle due to adaptation of a high occupancy vehicle lane to a high occupancy toll lane 

    E-Print Network [OSTI]

    Chum, Geoffrey Linus

    2009-05-15

    distributed to park-and-ride bus passengers on the Katy Freeway and Northwest Freeway corridors in Houston. Passengers’ responses to questions regarding their trip characteristics, their socioeconomic characteristics, and stated preference scenarios were used...

  6. Analysis of road pricing, metering and the priority treatment of high occupancy vehicles using system dynamics. Master's thesis

    SciTech Connect (OSTI)

    Castillo, W.

    1992-01-01

    Transportation Systems Management (TSM) employs various techniques such as road pricing, metering and the priority treatment of high occupancy vehicles (HOVs) in an effort to make more efficient use of existing transportation facilities. Efficiency is improved in terms of moving more people through the facility while simultaneously reducing the number of vehicles using the facility. This report uses a hypothetical toll facility and examines four computer modeling approaches to determine which of the approaches are valid in terms of predicting the behavior of trip makers seeking to use the facility in response to various combinations of TSM techniques. Once an approach has been determined to be valid, seven different combination of TSM techniques, or strategies, are compared to a base strategy to determine what strategy or strategies are most affective in achieving the goals of TSM.

  7. Cost-effectiveness of freeway median high occupancy vehicle (HOV) facility conversion to rail guideway transit 

    E-Print Network [OSTI]

    Best, Matthew Evans

    1996-01-01

    Many freeways in the United States contain median high occupancy vehicle (HOV) facilities. These facilities have been envisioned by some as reserved space for future rail guideway transit. This thesis examines the cost-effectiveness of converting a...

  8. Texas Toll Road Primer Final Report

    E-Print Network [OSTI]

    Texas Toll Road Primer Final Report PRC 14-3 F #12;Texas Toll Road Primer Texas A&M Transportation ............................................................................................... 11 Texas Legislation and Tolling............................................................ 25 Comparing Texas Toll Facilities to the Nation

  9. CRAD, Occupational Safety & Health- Oak Ridge National Laboratory High Flux Isotope Reactor Contractor ORR

    Broader source: Energy.gov [DOE]

    A section of Appendix C to DOE G 226.1-2 "Federal Line Management Oversight of Department of Energy Nuclear Facilities." Consists of Criteria Review and Approach Documents (CRADs) used for a February 2007 assessment of the Occupational Safety and Health Program portion of an Operational Readiness Review of the Oak Ridge National Laboratory High Flux Isotope Reactor.

  10. Potential single-occupancy vehicle demand for the Katy Freeway and Northwest Freeway high-occupancy vehicle lanes 

    E-Print Network [OSTI]

    Xu, Lei

    2006-10-30

    relatively low patronage after operating for over 6 years on the Katy Freeway and over 4 years on the Northwest Freeway. There existed an opportunity to increase the usage of these HOT lanes by allowing single-occupancy vehicle (SOV) travelers to use...

  11. Abstract--Airborne pollution and explosive gases threaten human health and occupational safety, therefore generating high

    E-Print Network [OSTI]

    Mason, Andrew

    Abstract--Airborne pollution and explosive gases threaten human health and occupational safety and a thumb-drive sized prototype system. I. INTRODUCTION xposure to air pollution consistently ranks among to occupational safety as energy demands rise. Airborne pollutants and explosive gases vary in both time and space

  12. CRAD, Occupational Safety & Health- Oak Ridge National Laboratory High Flux Isotope Reactor

    Broader source: Energy.gov [DOE]

    A section of Appendix C to DOE G 226.1-2 "Federal Line Management Oversight of Department of Energy Nuclear Facilities." Consists of Criteria Review and Approach Documents (CRADs) used for a February 2007 assessment of the Industrial Safety and Hygiene Program in preparation for restart of the Oak Ridge National Laboratory High Flux Isotope Reactor.

  13. The Middle East Roads, Bridges and Tolls

    E-Print Network [OSTI]

    Nagurney, Anna

    EconomicCrisis ­ Expatriatejobscut ­ Overconges8on · DubaiWorld'sDebt ­ Slowedexpansion ­ AbuDhabiBailout #12;Negatives Low Housing#12;#12;The Middle East #12;Dubai #12;#12;#12;#12;#12;#12;Roads, Bridges and Tolls RTA Two Major longest automatic driverless system in the world Red (2009) and Green Line (2010) 87 Trains 74

  14. OCCUPATIONAL HEALTH AND SAFETY

    E-Print Network [OSTI]

    OCCUPATIONAL HEALTH AND SAFETY MANAGEMENT SYSTEM Department of Occupational Health and Safety Revised December 2009 #12;Occupational Health and Safety (OHS) Management System 1. Introduction.............................................................................................................. 3 2.2 Management of Health and Safety

  15. PIA - Richland Occupational Medicine Contract | Department of...

    Energy Savers [EERE]

    PIA - Richland Occupational Medicine Contract PIA - Richland Occupational Medicine Contract PIA - Richland Occupational Medicine Contract PDF icon PIA - Richland Occupational...

  16. Valuation of the Indiana Toll Road and Chicago Skyway privatizations

    E-Print Network [OSTI]

    Chaudary, Faiza A. (Faiza Arshad)

    2010-01-01

    This thesis analyzes the economics and financing of the recent purchases of the Indiana Toll Road and Chicago Skyway. Similar privatizations have been occurring around the world, but the economic motive for such transactions ...

  17. Long run changes in driver behavior due to variable tolls 

    E-Print Network [OSTI]

    Konduru, Karun K.

    2004-09-30

    As many variable pricing projects are still in the implementation stage, long-run driver responses to the variable tolls are largely unknown. This research examined the long-run changes in driver behavior in an existing ...

  18. Occupational Health and Safety Manual

    E-Print Network [OSTI]

    Occupational Health and Safety Manual #12;1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 York University Occupational Health and Safety Policy and Programs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Occupational Health and Safety Legislation

  19. NREL: Continuum Magazine - Smart Occupancy Sensor Debuts

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of activity, and the amount of light in each. All of this allows for highly targeted control of lighting, heating, and other building systems based on occupant need. "The...

  20. Public Perceptions of Toll Roads: A Survey of the Texas Perspective

    E-Print Network [OSTI]

    Kockelman, Kara M.

    Public Perceptions of Toll Roads: A Survey of the Texas Perspective By Kaethe V. Podgorski Graduate 70% agreed on attending to existing roads first, keeping existing roads toll-free, reducing tolls. However, because these taxes have not been tied to inflation and improved vehicle fuel efficiencies have

  1. Energy Employees' Occupational Illness Compensation Program Act...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Employees' Occupational Illness Compensation Program Act (EEOICPA) Tracking Database, INL Energy Employees' Occupational Illness Compensation Program Energy Employees' Occupational...

  2. Occupational Medicine - Assistant PIA, Idaho National Laboratory...

    Energy Savers [EERE]

    Occupational Medicine - Assistant PIA, Idaho National Laboratory Occupational Medicine - Assistant PIA, Idaho National Laboratory Occupational Medicine - Assistant PIA, Idaho...

  3. The impact of a toll reduction for truck traffic using SH 130 Muhammad Ehsanul Bari *, Mark W. Burris 1

    E-Print Network [OSTI]

    Burris, Mark W.

    travel. A time series analysis of the toll transaction data, along with the local price of diesel fuel, unemployment rate, GDP, and income levels, resulted in a toll-price elasticity of À0.43 for 5-axle vehicles paid using electronic toll collection (ETC), and the remainder paid manually (MLT). The toll-price

  4. OCCUPATIONAL SAFETY and HEALTH

    E-Print Network [OSTI]

    MARYLAND OCCUPATIONAL SAFETY and HEALTH ACT safety and health protection on the job STATE OCCUPATIONAL SAFETY AND HEALTH STANDARDS, AND OTHER APPLICABLE REGULATIONS MAY BE OBTAINED FROM and Health Administration, The Curtis Center, Suite 740 West, 170 S. Independence Mall West, Philadelphia, PA

  5. Risk Level Based Management System: a control banding model for occupational health and safety risk management in a highly regulated environment

    SciTech Connect (OSTI)

    Zalk, D; Kamerzell, R; Paik, S; Kapp, J; Harrington, D; Swuste, P

    2009-05-27

    The Risk Level Based Management System (RLBMS) is an occupational risk management (ORM) model that focuses occupational safety, hygeiene, and health (OSHH) resources on the highest risk procedures at work. This article demonstrates the model's simplicity through an implementation within a heavily regulated research institution. The model utilizes control banding strategies with a stratification of four risk levels (RLs) for many commonly performed maintenance and support activities, characterizing risk consistently for comparable tasks. RLBMS creates an auditable tracking of activities, maximizes OSHH professional field time, and standardizes documentation and control commensurate to a given task's RL. Validation of RLs and their exposure control effectiveness is collected in a traditional quantitative collection regime for regulatory auditing. However, qualitative risk assessment methods are also used within this validation process. Participatory approaches are used throughout the RLBMS process. Workers are involved in all phases of building, maintaining, and improving this model. This work participation also improves the implementation of established controls.

  6. PRIVACY IMPACT ASSESSMENT: OCCUPATIONAL MEDICINE- INL OCCUPATIONAL

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergy AEnergyPresidential Permit authorizingAward FeeEducationOCCUPATIONAL MEDICINE-

  7. PRIVACY IMPACT ASSESSMENT: Occupational Safety Health Occupational

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergy AEnergyPresidential Permit authorizingAwardOccupational Safety & Health -

  8. Window Signaling Systems: Control Strategies & Occupant Behavior

    E-Print Network [OSTI]

    Ackerly, Katie; Brager, Gail

    2012-01-01

    Control Strategies & Occupant Behavior Katie Ackerly a ,signals play a role in occupant behavior and response. Theignored. Results: Occupant Behavior While thermal comfort

  9. Occupant Response to Window Control Signaling Systems

    E-Print Network [OSTI]

    Ackerly, Katherine

    2012-01-01

    Characterizing Occupant Behavior in Buildings: Towards a to thermal comfort – Occupant behavior and  energy use in at the relationship between occupant behavior, information 

  10. Pricing and Hedging Electricity Supply Contracts: a Case with Tolling Agreements

    E-Print Network [OSTI]

    Pricing and Hedging Electricity Supply Contracts: a Case with Tolling Agreements Shi-Jie Deng Email Customized electric power contracts catering to specific business and risk management needs have gained increasing popularity among large energy firms in the restructured electricity in- dustry. A tolling

  11. DOE HQ Occupational Safety and Health Program | Department of...

    Energy Savers [EERE]

    DOE HQ Occupational Safety and Health Program DOE HQ Occupational Safety and Health Program HQ Occupational Safety and Health Program Procedures PDF icon DOE HQ Occupational Safety...

  12. Toll road public-private partnerships in Malaysia : using the CLIOS process for policy improvements

    E-Print Network [OSTI]

    Ward, John L., 1977-

    2005-01-01

    Malaysia has relied on private sector provision of toll roads for over twenty years using public- private partnerships (PPPs). While the program has been successful in providing close to 1,800 kilometers of highway in that ...

  13. An analysis of the current investment trend in the U.S. toll road sector

    E-Print Network [OSTI]

    Zhang, Xin, S.M. Massachusetts Institute of Technology

    2008-01-01

    In recent years, long term concessions through public-private partnerships (PPP's) in the US toll road sector have emerged and are expected to become a phenomenon in the near future. Up until now, only two large scale ...

  14. Self/Non-self Discrimination by Toll-like Receptor 9

    E-Print Network [OSTI]

    Mouchess, Maria Luz

    2011-01-01

    by Toll-like Receptor 9 by Maria Luz Mouchess A dissertationlike Receptor 9 By Maria Luz Mouchess Doctor of Philosophywork to my parents, Maria Luz Jaramillo Mouchess and Luis

  15. Bioinformatic analysis of chicken chemokines, chemokine receptors, and Toll-like receptor 21 

    E-Print Network [OSTI]

    Wang, Jixin

    2006-10-30

    Chemokines triggered by Toll-like receptors (TLRs) are small chemoattractant proteins, which mainly regulate leukocyte trafficking in inflammatory reactions via interaction with G protein-coupled receptors. Forty-two ...

  16. Occupational Disease in Connecticut, 2014

    E-Print Network [OSTI]

    Oliver, Douglas L.

    Occupational Disease in Connecticut, 2014 This report covers data for 2012 and was prepared under contract for the State of Connecticut Workers' Compensation Commission, John A. Mastropietro, Chairman, as part of the Occupational Disease Surveillance Program, operated in cooperation with the Connecticut

  17. Image-based occupancy sensor

    DOE Patents [OSTI]

    Polese, Luigi Gentile; Brackney, Larry

    2015-05-19

    An image-based occupancy sensor includes a motion detection module that receives and processes an image signal to generate a motion detection signal, a people detection module that receives the image signal and processes the image signal to generate a people detection signal, a face detection module that receives the image signal and processes the image signal to generate a face detection signal, and a sensor integration module that receives the motion detection signal from the motion detection module, receives the people detection signal from the people detection module, receives the face detection signal from the face detection module, and generates an occupancy signal using the motion detection signal, the people detection signal, and the face detection signal, with the occupancy signal indicating vacancy or occupancy, with an occupancy indication specifying that one or more people are detected within the monitored volume.

  18. Safety & Occupational Health Specialist | Department of Energy

    Energy Savers [EERE]

    & Occupational Health Specialist Safety & Occupational Health Specialist Submitted by admin on Sat, 2015-10-17 00:14 Job Summary Organization Name Department Of Energy Agency...

  19. DOE 2010 occupational radiation exposure

    SciTech Connect (OSTI)

    none,

    2011-11-01

    The U.S. Department of Energy (DOE) Office of Analysis within the Office of Health, Safety and Security (HSS) publishes the annual DOE Occupational Radiation Exposure Report to provide an overview of the status of radiation protection practices at DOE.* The DOE 2010 Occupational Radiation Exposure Report provides an evaluation of DOE-wide performance regarding compliance with DOE Part 835 dose limits and as low as reasonably achievable (ALARA) process requirements. In addition, the report provides data to DOE organizations responsible for developing policies for protection of individuals from the effects of radiation. The report provides a summary and an analysis of occupational radiation exposure information from the monitoring of individuals involved in DOE activities. The occupational radiation exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site over the past 5 years.

  20. Environmental Occupational Health Protection Laws

    E-Print Network [OSTI]

    Ashford, Nicholas

    2008-01-01

    The manufacturing, processing, and use of chemicals and materials in industrial, workplaces are often accompanied by environmental, health, and safety hazards and risks. Occupational and environmental factors cause or ...

  1. Alberta's Occupational Health and Safety

    E-Print Network [OSTI]

    Machel, Hans

    Alberta's Occupational Health and Safety Regulations An Explanation of the New First Aid Regulation of the First Aid Regulation Alberta's newest edition of the First Aid Regulation (AR 48/2000) came into effect

  2. FAQS Reference Guide – Occupational Safety

    Broader source: Energy.gov [DOE]

    This reference guide has been developed to address the competency statements in the July 2011 version of DOE-STD-1160-2011, Occupational Safety Functional Area Qualification Standard.

  3. Occupational Medicine Workshops and Webinars

    Office of Energy Efficiency and Renewable Energy (EERE)

    The DOE Annual Occupational Medicine Workshop & Webinar (OMWW) is a valuable training opportunity established by the Office of Health, Safety, and Security in support of hundreds of medical and allied health professionals located at over four dozen locations across the Department. Their vital work in the field of Occupational Medicine encompasses medical qualification examinations, injury and illness management, disability management, workers’ compensation, and much more.

  4. Fact #604: January 4, 2010 HOT Lanes in the U.S.

    Broader source: Energy.gov [DOE]

    There are six States that currently have high-occupancy toll (HOT) lanes. These lanes are similar to high-occupancy vehicle (HOV) lanes, except that they allow drivers of vehicles that do not meet...

  5. Occupant Behavior: Impact on Energy Use of Private Offices

    E-Print Network [OSTI]

    Hong, Tianzhen

    2014-01-01

    H. 2009. Impact of occupant behavior on lighting energy use,ATIONAL L ABORATORY Occupant Behavior: Impact on Energy Useopportunity employer. Occupant Behavior: Impact on Energy

  6. Window signalling systems: control strategies and occupant behaviour

    E-Print Network [OSTI]

    Ackerly, Katie; Brager, Gail

    2013-01-01

    strategies and occupant behavior”. Building Research &control strategies and occupant behavior Katie Ackerly a,signals play a role in occupant behavior and response. The

  7. Revealing Occupancy Diversity Factors in Buildings Using Sensor Data

    E-Print Network [OSTI]

    Bouffaron, Pierrick

    2014-01-01

    prediction based on occupant behavior assessment. Energy andbehavior is considered stochastic in nature. Occupants’behavior is considered stochastic in nature (Virote 2012). Occupants

  8. Occupational Health Manager PIA, Carlsbad Field Office | Department...

    Energy Savers [EERE]

    Occupational Health Manager PIA, Carlsbad Field Office Occupational Health Manager PIA, Carlsbad Field Office Occupational Health Manager PIA, Carlsbad Field Office PDF icon...

  9. MODELING CITIES WITH CONGESTION AND AGGLOMERATION EXTERNALITIES: THE EFFICIENCY OF CONGESTION TOLLS, LABOR

    E-Print Network [OSTI]

    Kockelman, Kara M.

    1 MODELING CITIES WITH CONGESTION AND AGGLOMERATION EXTERNALITIES: THE EFFICIENCY OF CONGESTION, Agglomeration, Pigouvian Congestion Tolling, Urban Growth Boundaries 1. INTRODUCTION Cities are full pollution and greenhouse gases, and raises a community's energy demands. Across the U.S.'s early 500 urban

  10. The Arizona Poison and Drug Information Center's toll-free line

    E-Print Network [OSTI]

    Arizona, University of

    The Arizona Poison and Drug Information Center's toll-free line is always open. Call us if: · You think someone has been poisoned. · You have questions about any type of poison. · You want information about poison prevention. Storing Safely · Lock up poisonous products and medicines out of reach and out

  11. The Arizona Poison and Drug Information Center's toll free line is

    E-Print Network [OSTI]

    Arizona, University of

    The Arizona Poison and Drug Information Center's toll free line is always open. Call us if: · You think someone has been poisoned. · You have questions about any type of poison. · You want information about poison prevention. Storing Safely · Lock up poisonous products and medicines out of reach and out

  12. Andrew Odlyzko 2006 32 Chapter 4: Economic costs of toll access

    E-Print Network [OSTI]

    Odlyzko, Andrew M.

    © Andrew Odlyzko 2006 32 Chapter 4: Economic costs of toll access Andrew Odlyzko Introduction Many. The invention of printing lowered the costs of information dissemination, and largely eliminated the job costs are higher than those of libraries, and it enables new types of scholarly communication (as well

  13. The impact of incentives on the use of toll roads by trucks 

    E-Print Network [OSTI]

    Zhou, Lin

    2010-07-14

    ..................................................... 57? 3.3.2 Statistical Tests ........................................................................... 58? 3.3.3 Discrete Choice Modeling .......................................................... 59? IV DATA ANALYSIS AND RESULTS... result in serious financial difficulties for the toll authority and anyone who may have backed the bonds. This thesis follows the style of the ASCE Journal of Transportation Engineering. 2 Additionally, the benefits of diverting traffic from...

  14. Demo Abstract: TOSS: Thermal Occupancy Sensing System

    E-Print Network [OSTI]

    Cerpa, Alberto E.

    occupancy. These include passive infrared sensors (PIR) [4] [8], carbon dioxide detection [2], and optical be remotely adjusted. Based on current detected occupancy, TOSS is able to control HVAC and lighting actuators

  15. Linking occupant complaints to building performance

    E-Print Network [OSTI]

    Goins, John; Moezzi, Mithra

    2012-01-01

    behavior is likely in commercial buildings too, especially where occupantsOccupant Complaints http://escholarship.org/uc/item/09z5423x Reflecting on Homburg and Furst's trio of defensive organizational behavior

  16. Occupational Medical Surveillance System (OMSS) PIA, Idaho National...

    Energy Savers [EERE]

    (OMSS) PIA, Idaho National Laboratory More Documents & Publications Occupational Medicine - Assistant PIA, Idaho National Laboratory Occupational Injury & Illness System...

  17. Pantex Occupational Health System (OHS), National Nuclear Security...

    Energy Savers [EERE]

    Pantex Occupational Health System (OHS), National Nuclear Security Administration Pantex Site Office Pantex Occupational Health System (OHS), National Nuclear Security...

  18. DOE 2012 Occupational Radiation Exposure October 2013

    SciTech Connect (OSTI)

    2012-02-02

    The U.S. Department of Energy (DOE) Office of Analysis within the Office of Health, Safety and Security (HSS) publishes the annual DOE Occupational Radiation Exposure Report to provide an overview of the status of radiation protection practices at DOE (including the National Nuclear Security Administration [NNSA]). The DOE 2012 Occupational Radiation Exposure Report provides an evaluation of DOE-wide performance regarding compliance with Title 10, Code of Federal Regulations (C.F.R.), Part 835, Occupational Radiation Protection dose limits and as low as reasonably achievable (ALARA) process requirements. In addition, the report provides data to DOE organizations responsible for developing policies for protection of individuals from the adverse health effects of radiation. The report provides a summary and an analysis of occupational radiation exposure information from the monitoring of individuals involved in DOE activities. Over the past 5-year period, the occupational radiation exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site. As an indicator of the overall amount of radiation dose received during the conduct of operations at DOE, the report includes information on collective total effective dose (TED). The TED is comprised of the effective dose (ED) from external sources, which includes neutron and photon radiation, and the internal committed effective dose (CED), which results from the intake of radioactive material into the body. The collective ED from photon exposure decreased by 23% between 2011 and 2012, while the neutron dose increased by 5%. The internal dose components of the collective TED decreased by 7%. Over the past 5-year period, 99.99% of the individuals receiving measurable TED have received doses below the 2 roentgen equivalent in man (rems) (20 millisievert [mSv]) TED administrative control level (ACL), which is well below the DOE regulatory limit of 5 rems (50 mSv) TED annually. The occupational radiation exposure records show that in 2012, DOE facilities continued to comply with DOE dose limits and ACLs and worked to minimize exposure to individuals. The DOE collective TED decreased 17.1% from 2011 to 2012. The collective TED decreased at three of the five sites with the largest collective TED. u Idaho Site – Collective dose reductions were achieved as a result of continuing improvements at the Advanced Mixed Waste Treatment Project (AMWTP) through the planning of drum movements that reduced the number of times a container is handled; placement of waste containers that created highradiation areas in a centralized location; and increased worker awareness of high-dose rate areas. In addition, Idaho had the largest decrease in the total number of workers with measurable TED (1,143 fewer workers). u Hanford Site (Hanford) – An overall reduction of decontamination and decommissioning (D&D) activities at the Plutonium Finishing Plant (PFP) and Transuranic (TRU) retrieval activities resulted in collective dose reductions. u Savannah River Site (SRS) – Reductions were achieved through ALARA initiatives employed site wide. The Solid Waste Management Facility used extended specialty tools, cameras and lead shield walls to facilitate removal of drums. These tools and techniques reduce exposure time through improved efficiency, increase distance from the source of radiation by remote monitoring, shield the workers to lower the dose rate, and reduce the potential for contamination and release of material through repacking of waste. Overall, from 2011 to 2012, there was a 19% decrease in the number of workers with measurable dose. Furthermore, due to a slight decrease in both the DOE workforce (7%) and monitored workers (10%), the ratio of workers with measurable doses to monitored workers decreased to 13%. Another primary indicator of the level of radiation exposure covered in this report is the average measurable dose, which normalizes the collective dose over the population of workers who actually received a measurable dose. The average measurable TED in

  19. Beryllium - HPMC Occupational Health Services

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 OutreachProductswsicloudwsiclouddenDVA N C E D B L O OLaura| National2.11DESERT *BerkeleyBerkeley SiteOccupational

  20. Annual DOE Occupational Radiation Exposure | 1974 Report

    Broader source: Energy.gov [DOE]

    The Seventh Annual Report of Radiation Exposures for AEC & AEC Contractor Employees analyzes occupational radiation exposures at the Atomic Energy Commission (AEC) and its contractor employees during 1974.

  1. Occupant Response to Window Control Signaling Systems

    E-Print Network [OSTI]

    Ackerly, Katherine

    2012-01-01

    and conventional  cooling systems.  Building Research & occupant type, cooling system and climate).  Understanding the hydronic  heating and cooling systems in the perimeter 

  2. Occupational Radiation Exposure | Department of Energy

    Office of Environmental Management (EM)

    Exposure Monitoring Systems (REMS) Radiation Exposure Monitoring System (REMS) is the database of occupational radiation exposures for all monitored DOE employees, contractors,...

  3. 2011 DOE Occupational Radiation Exposure Summary poster

    SciTech Connect (OSTI)

    ORAU

    2012-12-12

    This poster graphically presents data pertaining to occupational radiation exposure in terms of total effective dose (TED), primarily, but also collective dose and average measureable dose.

  4. Occupant Emergency Plans | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    documents for the Department of Energy, Headquarters buildings, in the Washington, DC, metropolitan area. Emergency Procedures Pamphlets Building Evacuation Routes Occupant...

  5. The 1986 residential occupant survey

    SciTech Connect (OSTI)

    Ivey, D.L.; Alley, P.K.

    1987-04-01

    In 1986, Pacific Northwest Laboratory developed the Residential Occupant Survey-Spring '86, which was implemented. The overall purpose of the study was to collect demographic, attitudinal, and behavioral data related to the use and conservation of electricity in dwellings participating in the Bonneville Power Administration's End-Use Load and Conservation Assessment Program (ELCAP). Information was collected on the respondents' perceptions of the energy efficiency of their dwelling, temperature the dwelling was kept when people were at home and awake during the last heating season, which rooms, if any, were not heated during the last heating season, number of times the dwelling was unoccupied for at least one week, number of times pets were let out of the dwelling per day, attitudes toward energy use and conservation and several socio-demographic variables such as age, sex, and total household income. The results of the data analyses showed age to be an important factor for reported indoor temperature and perceived energy efficiency of the dwelling. The results also showed that almost 60% of the ELCAP occupants do not heat one or more rooms during the heating season, and almost 45% of the ELCAP dwellings were unoccupied for at least one week during the reporting period. In terms of the reported allocation of household income for household energy expenses, the results showed that the reported dollar amount spent for the expenses remained relatively constant over income levels.

  6. Graduate Diploma in Occupational Safety & Health/

    E-Print Network [OSTI]

    Graduate Diploma in Occupational Safety & Health/ MSc in Occupational Safety & Health UCD School of Public Health, Physiotherapy and Sports Science www.ucd.ie/cshw/ GRADUATE Understanding your Degree Safety and Health (OSH), who have not previously achieved a higher level qualification in OSH. At the end

  7. Promising Technology: Wireless Lighting Occupancy Sensors

    Broader source: Energy.gov [DOE]

    Occupancy sensors and controls detect human presence, and modulate light settings accordingly. When there is no human presence detected, the system can dim or turn off lights. This technology ensures that lights are not used when there are no occupants present, which can lead to significant energy savings.

  8. UNIVERSITY HEALTH CENTER UGA OCCUPATIONAL HEALTH

    E-Print Network [OSTI]

    Arnold, Jonathan

    UNIVERSITY HEALTH CENTER UGA OCCUPATIONAL HEALTH APPROVAL FOR PHYSICAL EXAMS, EYE EXAMS, LAB WORK No Faculty/Staff: Yes No UGA Employment: Full-Time Part-Time New to Occupational Health Program? Yes No E: Release of Information: I authorize the University Health Center ("UHC") at The University of Georgia

  9. A COMPUTATIONAL FRAMEWORK INCORPORATING HUMAN AND SOCIAL BEHAVIORS FOR OCCUPANT-

    E-Print Network [OSTI]

    Stanford University

    A COMPUTATIONAL FRAMEWORK INCORPORATING HUMAN AND SOCIAL BEHAVIORS FOR OCCUPANT- CENTRIC highlighted the need to consider occupants' behaviors for better understanding of evacuation framework, occupants' behaviors in emergencies are analyzed by conducting a thorough review

  10. Occupational Electric Shocks, Electromagnetic Fields and Amyotrophic Lateral Sclerosis

    E-Print Network [OSTI]

    Vergara, Ximena Patricia

    2012-01-01

    working near machines with electric motors, and welders haveelectric shock exposure categorization is somewhat uncertain, especially for specific occupations such as office machineelectric shocks and electrocutions were precision production, craft and repair occupations, followed by service occupations and machine

  11. Occupancy change detection system and method

    DOE Patents [OSTI]

    Bruemmer, David J. (Idaho Falls, ID) [Idaho Falls, ID; Few, Douglas A. (Idaho Falls, ID) [Idaho Falls, ID

    2009-09-01

    A robot platform includes perceptors, locomotors, and a system controller. The system controller executes instructions for producing an occupancy grid map of an environment around the robot, scanning the environment to generate a current obstacle map relative to a current robot position, and converting the current obstacle map to a current occupancy grid map. The instructions also include processing each grid cell in the occupancy grid map. Within the processing of each grid cell, the instructions include comparing each grid cell in the occupancy grid map to a corresponding grid cell in the current occupancy grid map. For grid cells with a difference, the instructions include defining a change vector for each changed grid cell, wherein the change vector includes a direction from the robot to the changed grid cell and a range from the robot to the changed grid cell.

  12. The DOE Security Plan for the Energy Employees Occupational Illness...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    The DOE Security Plan for the Energy Employees Occupational Illness Compensation Program The DOE Security Plan for the Energy Employees Occupational Illness Compensation Program...

  13. LM Records Handling System (LMRHS01) - Energy Employees Occupational...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Employees Occupational Illness Compensation Program Act, Office of Legacy Management LM Records Handling System (LMRHS01) - Energy Employees Occupational Illness...

  14. Occupational Injury & Illness System (01&15) PIA, Idaho National...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Tracking Database, INL Energy Employees' Occupational Illness Compensation Program Occupational Medicine - Assistant PIA, Idaho National Laboratory VisitDosimBadgeTrckg-PIA.pdf...

  15. Occupational Medicine Implications of Engineered Nanoscale Particulate Matter

    E-Print Network [OSTI]

    Kelly, Richard J.

    2008-01-01

    New England Journal of Medicine 1993, 329, 7. S. v. Klot; A.34 of 42 Occupational Medicine Implications of Engineered35 of 42 Occupational Medicine Implications of Engineered

  16. 2015 DOE Annual Occupational Medicine Workshop & Webinar (OMWW...

    Broader source: Energy.gov (indexed) [DOE]

    DOE Annual Occupational Medicine Workshop & Webinar (OMWW) - March 16-17, 2015 The DOE Annual Occupational Medicine Workshop & Webinar (OMWW) is a valuable training opportunity...

  17. CRAD, Occupational Safety & Health - Los Alamos National Laboratory...

    Office of Environmental Management (EM)

    Occupational Safety & Health - Los Alamos National Laboratory TA 55 SST Facility CRAD, Occupational Safety & Health - Los Alamos National Laboratory TA 55 SST Facility A section of...

  18. Federal Employee Occupational Safety And Health (FEOSH) Program...

    Energy Savers [EERE]

    Federal Employee Occupational Safety And Health (FEOSH) Program Overview Federal Employee Occupational Safety And Health (FEOSH) Program Overview Congress established Public Law...

  19. Hawaii Department of Labor and Industrial Relations Occupational...

    Open Energy Info (EERE)

    Labor and Industrial Relations Occupational Safety and Health Division Jump to: navigation, search Name: Hawaii Department of Labor and Industrial Relations Occupational Safety and...

  20. A Method for Modeling Household Occupant Behavior to Simulate Residential Energy Consumption

    SciTech Connect (OSTI)

    Johnson, Brandon J [ORNL] [ORNL; Starke, Michael R [ORNL] [ORNL; Abdelaziz, Omar [ORNL] [ORNL; Jackson, Roderick K [ORNL] [ORNL; Tolbert, Leon M [University of Tennessee, Knoxville (UTK)] [University of Tennessee, Knoxville (UTK)

    2014-01-01

    This paper presents a statistical method for modeling the behavior of household occupants to estimate residential energy consumption. Using data gathered by the U.S. Census Bureau in the American Time Use Survey (ATUS), actions carried out by survey respondents are categorized into ten distinct activities. These activities are defined to correspond to the major energy consuming loads commonly found within the residential sector. Next, time varying minute resolution Markov chain based statistical models of different occupant types are developed. Using these behavioral models, individual occupants are simulated to show how an occupant interacts with the major residential energy consuming loads throughout the day. From these simulations, the minimum number of occupants, and consequently the minimum number of multiple occupant households, needing to be simulated to produce a statistically accurate representation of aggregate residential behavior can be determined. Finally, future work will involve the use of these occupant models along side residential load models to produce a high-resolution energy consumption profile and estimate the potential for demand response from residential loads.

  1. Structure of Human Toll-like Receptor 3 (TLR3) Ligand-binding Domain

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust,Field-effect PhotovoltaicsStructure and Receptor Specificity ofHuman Toll-like Receptor 3

  2. 851 S.W. Sixth Avenue, Suite 1100 Telephone: 503-222-5161 Fax: 503-820-2370 Portland, Oregon 97204-1348 Toll free: 800-452-5161 Web site: www.nwcouncil.org

    E-Print Network [OSTI]

    -1348 Toll free: 800-452-5161 Web site: www.nwcouncil.org JUDI DANIELSON CHAIR Idaho TOM KARIER VICE

  3. DOE 2010 Occupational Radiation Exposure November 2011

    SciTech Connect (OSTI)

    U.S. Department of Energy, Office of Health, Safety and Security, Office of Analysis

    2011-11-11

    This report discusses radiation protection and dose reporting requirements, presents the 2010 occupational radiation dose data trended over the past 5 years, and includes instructions to submit successful ALARA projects.

  4. Annual DOE Occupational Radiation Exposure | 1978 Report

    Broader source: Energy.gov [DOE]

    The Eleventh Annual Report of Radiation Exposures for DOE & DOE Contractor Employees analyzes occupational radiation exposures at the U.S. Department of Energy (DOE) and its contractor employees during 1978.

  5. Annual DOE Occupational Radiation Exposure | 1977 Report

    Broader source: Energy.gov [DOE]

    The Tenth Annual Report of Radiation Exposures for DOE & DOE Contractor Employees analyzes occupational radiation exposures at the U.S. Department of Energy (DOE) and its contractor employees during 1977.

  6. Annual DOE Occupational Radiation Exposure | 1975 Report

    Office of Energy Efficiency and Renewable Energy (EERE)

    The Eighth Annual Report of Radiation Exposures for ERDA & ERDA Contractor Employees analyzes occupational radiation exposures at the Energy Research and Development Administration (ERDA) and its contractor employees during 1975.

  7. Annual DOE Occupational Radiation Exposure | 1976 Report

    Broader source: Energy.gov [DOE]

    The Ninth Annual Report of Radiation Exposures for DOE & DOE Contractor Employees analyzes occupational radiation exposures at the U.S. Department of Energy (DOE) and its contractor employees during 1976.

  8. Occupational Radiation Protection Program (10 CFR 835)

    Broader source: Energy.gov [DOE]

    The occupational radiation protection program is governed by the Rule, specified as 10 CFR 835. The requirements given in 10 CFR 835 are matters of law, punishable by civil and criminal penalties.

  9. Annual DOE Occupational Radiation Exposure | 1984 Report

    Broader source: Energy.gov [DOE]

    The Seventeenth Annual Report of Radiation Exposures for DOE & DOE Contractor Employees analyzes occupational radiation exposures at the U.S. Department of Energy (DOE) and its contractor employees during 1984.

  10. Annual DOE Occupational Radiation Exposure | 1986 Report

    Broader source: Energy.gov [DOE]

    The Nineteenth Annual Report of Radiation Exposures for DOE & DOE Contractor Employees analyzes occupational radiation exposures at the U.S. Department of Energy (DOE) and its contractor employees during 1986.

  11. Ann. Occup. Hyg. Page 1 of 13

    E-Print Network [OSTI]

    Krishnamoorthy, Kalimuthu

    in the industrial hygiene literature due to its common occurrence among exposure data and due to the challengesOxfordUniversityPresson behalf of the British Occupational Hygiene Society. Tests for an Upper Percentile of a Lognormal

  12. Achieving Sustainability, Energy Savings, and Occupant Comfort 

    E-Print Network [OSTI]

    Fisher, D.; Bristow, G.

    2009-01-01

    Sustainability, energy savings, and occupant comfort are not mutually exclusive objectives, as buildings can be designed that incorporate all of these features. Sustainability is often defined as meeting the needs of the present without compromising...

  13. Annual DOE Occupational Radiation Exposure | 1985 Report

    Broader source: Energy.gov [DOE]

    The Eighteenth Annual Report of Radiation Exposures for DOE & DOE Contractor Employees analyzes occupational radiation exposures at the U.S. Department of Energy (DOE) and its contractor employees during 1985.

  14. Annual DOE Occupational Radiation Exposure | 1982 Report

    Broader source: Energy.gov [DOE]

    The Fifteenth Annual Report of Radiation Exposures for DOE & DOE Contractor Employees analyzes occupational radiation exposures at the U.S. Department of Energy (DOE) and its contractor employees during 1982.

  15. Annual DOE Occupational Radiation Exposure | 1979 Report

    Broader source: Energy.gov [DOE]

    The Twelfth Annual Report of Radiation Exposures for DOE & DOE Contractor Employees analyzes occupational radiation exposures at the U.S. Department of Energy (DOE) and its contractor employees during 1979.

  16. Annual DOE Occupational Radiation Exposure | 1983 Report

    Broader source: Energy.gov [DOE]

    The Sixteenth Annual Report of Radiation Exposures for DOE & DOE Contractor Employees analyzes occupational radiation exposures at the U.S. Department of Energy (DOE) and its contractor employees during 1983.

  17. Annual DOE Occupational Radiation Exposure | 1980 Report

    Broader source: Energy.gov [DOE]

    The Thirteenth Annual Report of Radiation Exposures for DOE & DOE Contractor Employees analyzes occupational radiation exposures at the U.S. Department of Energy (DOE) and its contractor employees during 1980.

  18. Annual DOE Occupational Radiation Exposure | 1981 Report

    Broader source: Energy.gov [DOE]

    The Fourteenth Annual Report of Radiation Exposures for DOE & DOE Contractor Employees analyzes occupational radiation exposures at the U.S. Department of Energy (DOE) and its contractor employees during 1981.

  19. Hanford Site lighting occupancy sensor study

    SciTech Connect (OSTI)

    Richman, E.E.; Dittmer, A.L.; Keller, J.M.

    1993-09-01

    This study was designed to assess the potential energy savings from the use of lighting occupancy sensor control in the US Department of Energy (DOE) Hanford Site office facilities. The final results of the study provide useful information for assessing cost-effective use of occupancy sensor lighting control. The results also include specific application data for Hanford Site office building spaces that indicate where sensor technology could be applied for cost-effective energy savings.

  20. A Comparison of Static and Dynamic Traffic Assignment Under Tolls: A Study of the Dallas-Fort Worth Network

    E-Print Network [OSTI]

    Kockelman, Kara M.

    A Comparison of Static and Dynamic Traffic Assignment Under Tolls: A Study of the Dallas-Fort Worth, most of the work in the literature uses static transportation models for analysis. The benefits comparison of static traffic assignment with the VISTA model, a simulation-based dynamic traffic assignment

  1. Optimization of Occupancy Based Demand Controlled Ventilation in Residences

    SciTech Connect (OSTI)

    Mortensen, Dorthe K.; Walker, Iain S.; Sherman, Max H.

    2011-05-01

    Although it has been used for many years in commercial buildings, the application of demand controlled ventilation in residences is limited. In this study we used occupant exposure to pollutants integrated over time (referred to as 'dose') as the metric to evaluate the effectiveness and air quality implications of demand controlled ventilation in residences. We looked at air quality for two situations. The first is that typically used in ventilation standards: the exposure over a long term. The second is to look at peak exposures that are associated with time variations in ventilation rates and pollutant generation. The pollutant generation had two components: a background rate associated with the building materials and furnishings and a second component related to occupants. The demand controlled ventilation system operated at a low airflow rate when the residence was unoccupied and at a high airflow rate when occupied. We used analytical solutions to the continuity equation to determine the ventilation effectiveness and the long-term chronic dose and peak acute exposure for a representative range of occupancy periods, pollutant generation rates and airflow rates. The results of the study showed that we can optimize the demand controlled airflow rates to reduce the quantity of air used for ventilation without introducing problematic acute conditions.

  2. Occupational stress and coping mechanisms as perceived by the directors of adult literacy educational programs in Texas 

    E-Print Network [OSTI]

    Austin, Melinda Weatherford

    2005-08-29

    of adult literacy education program directors in Texas experienced a significant level of occupational stress and a high overall general stress level. 2. The top stressors identified by the program directors were: Data Collection/Analysis, Statewide...

  3. Transportation Secure Data Center: Real-World Data for Value Pricing and Tolling Research (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-01-01

    The National Renewable Energy Laboratory (NREL) and the U.S. Department of Transportation (DOT) have launched the free, web-based Transportation Secure Data Center (TSDC). The TSDC (www.nrel.gov/tsdc) preserves respondent anonymity while making vital transportation data available to a broad group of users through secure, online access. The TSDC database provides free-of-charge web-based access to valuable transportation data that can be used for: Location and time-of-day variable tolling research, Mileage-based fee analysis, Travel demand modeling and transit planning, Congestion mitigation research, and Validating transportation data from other sources. The TSDC's two levels of access make composite data available with simple online registration, and allow researchers to use detailed spatial data after completing a straight forward application process.

  4. Collecting Occupant Presence Data for Use in Energy Management of Commercial Buildings

    E-Print Network [OSTI]

    Rosenblum, Benjamin Tarr

    2012-01-01

    relationship between occupant behavior and energy efficiencyin relation to occupant behavior, understand how occupantpresence is a subset of occupant behavior, which includes a

  5. Human Behavior Meets Building Intelligence: How Occupants Respond to “Open Window” Signals

    E-Print Network [OSTI]

    Ackerly, Katie; Brager, Gail

    2012-01-01

    the signal message and occupant behavior were by and largesystem is in moving occupant behavior towards design teamobjectives and occupant control behaviors related to comfort

  6. Occupant Control of Windows: Accounting for Human Behavior in Building Simulation

    E-Print Network [OSTI]

    Borgeson, Sam; Brager, Gail

    2008-01-01

    Through the study of occupant behavior and mixed- modeCharacterizing Occupant Behavior in Buildings: Towards ato thermal comfort – Occupant behavior and energy use in

  7. A technical framework to describe occupant behavior for building energy simulations

    E-Print Network [OSTI]

    Turner Ph.D., William

    2014-01-01

    Hong and H. Lin, “Occupant Behavior?: Impact on Energy Useand validation of occupant behavior models, while alsoframework to describe occupant behavior for building energy

  8. Occupancy-Based Energy Management in Buildings: Final Report to Sponsors

    E-Print Network [OSTI]

    Sohn, Michael D.

    2010-01-01

    Occupancy- Based Energy Management Systems for Buildings:Occupancy-Based Energy Management System. The objective ofOccupancy-Based Energy Management System. The experiments to

  9. Occupancy Simulation Schedule Appendix C -Occupancy Simulation Schedule

    E-Print Network [OSTI]

    into the electrical panel for run times commensurate with identified use profiles. The profiles enabled sought set of experiments detailing the cooling season implications of the high-performance windows. Figure C

  10. Halo occupation numbers and galaxy bias

    E-Print Network [OSTI]

    J. A. Peacock; R. E. Smith

    2000-06-30

    We propose a heuristic model that displays the main features of realistic theories for galaxy bias. We show that the low-order clustering statistics of the dark-matter distribution depend almost entirely on the locations and density profiles of dark-matter haloes. A hypothetical galaxy catalogue depends on (i) the efficiency of galaxy formation, as manifested by the halo occupation number -- the number of galaxies brighter than some sample limit contained in a halo of a given mass; (ii) the location of these galaxies within their halo. The first factor is constrained by the empirical luminosity function of groups. For the second factor, we assume that one galaxy marks the halo centre, with any remaining galaxies acting as satellites that trace the halo mass. These simple assumptions amount to a recipe for non-local bias, in which the probability of finding a galaxy is not a simple function of its local mass density. We have applied this prescription to some CDM models of current interest, and find that the predictions are close to the observed galaxy correlations for a flat $\\Omega=0.3$ model ($\\Lambda$CDM), but not for an $\\Omega=1$ model with the same power spectrum ($\\tau$CDM). This is an inevitable consequence of cluster normalization for the power spectra: cluster-scale haloes of given mass have smaller core radii for high $\\Omega$, and hence display enhanced small-scale clustering. Finally, the pairwise velocity dispersion of galaxies in the $\\Lambda$CDM model is lower than that of the mass, allowing cluster-normalized models to yield a realistic Mach number for the peculiar velocity field. This is largely due to the strong variation of galaxy-formation efficiency with halo mass that is required in this model.

  11. DOE Occupational Radiation Exposure, 2001 report

    SciTech Connect (OSTI)

    None, None

    2001-12-31

    The goal of the U.S. Department of Energy (DOE) is to conduct its operations, including radiological, to ensure the safety and health of all DOE employees, contractors, and subcontractors. The DOE strives to maintain radiation exposures to its workers below administrative control levels and DOE limits and to further reduce these exposures to levels that are “As Low As Reasonably Achievable” (ALARA). The 2001 DOE Occupational Radiation Exposure Report provides a summary and analysis of the occupational radiation exposure received by individuals associated with DOE activities. The DOE mission includes stewardship of the nuclear weapons stockpile and the associated facilities, environmental restoration of DOE, and energy research.

  12. Development and Validation of an Occupational Skills Assessment Instrument

    E-Print Network [OSTI]

    Mathews, R. Mark; Whang, Paula L.; Fawcett, Stephen B.

    1980-01-01

    The development and validation of an occupational skills assessment instrument is described. The instrument was designed to describe accurately a participant's actual level of occupational skills in a variety of job-related ...

  13. Occupational and Environmental Clinical Medicine II

    E-Print Network [OSTI]

    Finley Jr., Russell L.

    Occupational and Environmental Medicine Years I-IV 2014-2015 Year II Clinical Medicine II · Toxicology- 4 lecture unit · Clinical Correlations: Poisoned Patient- 2 lecture unit Year I Clinical MedicineDetroit · Earthworks · Greening of Detroit Street Medicine · Detroit Clean Up Clinical Education Year III Family

  14. Using occupancy to reduce energy consumption of buildings

    E-Print Network [OSTI]

    Balaji, Bharathan

    2011-01-01

    and is designed with Smart Home applications in mind.Smart Thermostat: Using Occupancy Sensors to Save Energy in Homes.

  15. Occupation by “induction”: The American Army of Occupation in Cuba, December 1898-December 1899 

    E-Print Network [OSTI]

    Askew, Mark C

    2015-04-30

    Many historians of the first American occupation of Cuba (1898-1902) assert that the military government of the island began and ended with a single strategic objective in mind: annexation. This assertion, however, ignores ...

  16. Occupational therapy is a healthcare profession that provides services to

    E-Print Network [OSTI]

    Sibille, Etienne

    Occupational therapy is a healthcare profession that provides services to individuals of all ages of occupational therapy services, and contributor to the profession. The occupational therapist practitioner and healthcare, participates in clinical research, and advocates appropriately for clients and the profession

  17. Forecasting Building Occupancy Using Sensor Network James Howard

    E-Print Network [OSTI]

    Hoff, William A.

    Forecasting Building Occupancy Using Sensor Network Data James Howard Colorado School of Mines@mines.edu ABSTRACT Forecasting the occupancy of buildings can lead to signif- icant improvement of smart heating throughout a building, we perform data mining to forecast occupancy a short time (i.e., up to 60 minutes

  18. Occupant Response to Window Control Signaling Systems; Appendix C: Mixed-mode Signal Case Study Summary

    E-Print Network [OSTI]

    Ackerly, Katie; Brager, Gail

    2011-01-01

    independently of occupant behavior. System Description Thein group 4 because occupant behavior has no bearing on the

  19. The occupancy in the Hadronic Calorimeter endcap of the CLIC detector

    E-Print Network [OSTI]

    van Dam, S.B.

    2014-01-01

    To achieve the optimal physics performance of a detector for a linear electron–positron col- lider it is essential to minimize the effect of the beam-induced background. Incoherent electron–positron pairs shower in the very forward region of the CLIC detector and cause a too high occupancy of approximately 80% in the inner radius of the HCal endcap. The occupancy is studied by performing full detector simulations and reduced by changing the material and thickness of the support tube that serves as shielding. The effect of the tile size in the HCal endcap is also studied. A minimal occupancy of ? 4% in the HCal inner radius can be reached with a thick tungsten support tube. When taking a more realistic engineering point of view into account and including polyethylene, an occupancy of ? 8% is achieved. These results show that it is possible to reduce the occupancy due to incoherent pairs in the HCal endcap to a similar level as that due to gg ! hadrons events.

  20. A methodology for identifying and improving occupant behavior in residential Zhun (Jerry) Yu a

    E-Print Network [OSTI]

    Fung, Benjamin C. M.

    sector worldwide [4e6]. The high energy demand in residential buildings, which is also growing rapidlyA methodology for identifying and improving occupant behavior in residential buildings Zhun (Jerry in existing residential buildings. In this study, end-use loads were divided into two levels (i.e. main

  1. Sensitivity of Building Energy Simulation with Building Occupancy for a University Building 

    E-Print Network [OSTI]

    Chhajed, Shreyans

    2014-08-01

    during breaks to very high during peak daytime hours in the middle of the semester. This paper presents how an energy simulation model was built and validated and then used to explore the effect of occupancy for a classroom/studio building on the campus...

  2. 851 S.W. Sixth Avenue, Suite 1100 Telephone: 503-222-5161 Fax: 503-820-2370 Portland, Oregon 97204-1348 Toll free: 800-452-5161 Web site: www.nwcouncil.org

    E-Print Network [OSTI]

    -1348 Toll free: 800-452-5161 Web site: www.nwcouncil.org Melinda S. Eden Chair Oregon Jim Kempton Vice

  3. DOE occupational radiation exposure 2000 report

    SciTech Connect (OSTI)

    none,

    2000-12-31

    The U.S. Department of Energy (DOE) Office of Safety and Health publishes the annual DOE Occupational Radiation Exposure Report. This report is intended to be a valuable tool for DOE and DOE contractor managers in managing radiological safety programs and to assist them in prioritizing resources. We appreciate the efforts and contributions from the various stakeholders within and outside DOE in making this report most useful to them. This report includes occupational radiation exposure information for all monitored DOE employees, contractors, subcontractors, and visitors. The exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site. For the purposes of examining trends, data for the past 5 years are included in the analysis.

  4. DOE occupational radiation exposure 1998 report

    SciTech Connect (OSTI)

    none,

    1998-12-31

    The U.S. Department of Energy (DOE) Office of Environment, Safety and Health with support from Environment Safety and Health Technical Information Services publishes the DOE Occupational Radiation Exposure Report. This report is intended to be a valuable tool for DOE/DOE contractor managers in managing radiological safety programs and to assist them in prioritizing resources. We appreciate the efforts and contributions from the various stakeholders within and outside DOE and hope we have succeeded in making the report more useful. This report includes occupational radiation exposure information for all monitored DOE employees, contractors, subcontractors, and visitors. The exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site. For the purposes of examining trends, data for the past 5 years are included in the analysis.

  5. DOE occupational radiation exposure 1997 report

    SciTech Connect (OSTI)

    none,

    1997-12-31

    The U.S. Department of Energy (DOE) Office of Environment, Safety and Health publishes the DOE Occupational Radiation Exposure Report. This report is intended to be a valuable tool for DOE/DOE contractor managers in managing radiological safety programs and to assist them in prioritizing resources. We appreciate the efforts and contributions from the various stakeholders within and outside DOE and hope we have succeeded in making the report more useful. This report includes occupational radiation exposure information for all monitored DOE employees, contractors, subcontractors, and visitors. The exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site. For the purposes of examining trends, data for the past 5 years are included in the analysis.

  6. DOE occupational radiation exposure 1996 report

    SciTech Connect (OSTI)

    none,

    1996-12-31

    The U.S. Department of Energy (DOE) Office of Environment, Safety and Health publishes the DOE Occupational Radiation Exposure Report. This report is intended to be a valuable tool for DOE/DOE contractor managers in their management of radiological safety programs and to assist them in the prioritization of resources. We appreciate the efforts and contributions from the various stakeholders within and outside the DOE and hope we have succeeded in making the report more useful. This report includes occupational radiation exposure information for all DOE employees, contractors, subcontractors, and visitors. The exposure information is analyzed in terms of collective data, dose to individuals, and dose by site. For the purposes of examining trends, data for the past 5 years are included in the analysis.

  7. DOE occupational radiation exposure 2004 report

    SciTech Connect (OSTI)

    none,

    2004-12-31

    The U.S. Department of Energy (DOE) Office of Corporate Performance Assessment (EH-3) publishes the annual DOE Occupational Radiation Exposure Report. This report is intended to be a valuable tool for DOE and DOE contractor managers and workers in managing radiological safety programs and to assist them in prioritizing resources. We appreciate the efforts and contributions from the various stakeholders within and outside DOE to make the report most useful. This report includes occupational radiation exposure information for all monitored DOE employees, contractors, and subcontractors, as well as members of the public. DOE is defined to include the National Nuclear Security Administration sites. The exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site. For the purposes of examining trends, data for the past 5 years are included in the analysis.

  8. DOE occupational radiation exposure 2002 report

    SciTech Connect (OSTI)

    none,

    2002-12-31

    The U.S. Department of Energy (DOE) Office of Corporate Performance Assessment (EH-3) publishes the annual DOE Occupational Radiation Exposure Report. This report is intended to be a valuable tool for DOE and DOE contractor managers and workers in managing radiological safety programs and to assist them in prioritizing resources. We appreciate the efforts and contributions from the various stakeholders within and outside DOE to make the report most useful. This report includes occupational radiation exposure information for all monitored DOE employees, contractors, subcontractors, and members of the public. The exposure information is analyzed in terms of aggregate data, dose to individuals, and dose by site. For the purposes of examining trends, data for the past 5 years are included in the analysis.

  9. Headquarters Occupational Safety and Health Program

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2001-11-03

    To implement the Occupational Safety and Health Program for Department of Energy (DOE) Headquarters employees as an element of the DOE Integrated Safety Management System. Cancels: HQ 3790.2A. Canceled by DOE O 251.91. This directive was reviewed and certified as current and necessary by Bruce M. Carnes, Director, Office of Management, Budget and Evaluation/Chief Financial Officer, 9/18/02. Canceled by DOE N 251.91.

  10. Revealing Occupancy Patterns in Office Buildings Through the use of Annual Occupancy Sensor Data

    SciTech Connect (OSTI)

    Carlos Duarte; Kevin Van Den Wymelenberg; Craig Rieger

    2013-06-01

    Energy simulation programs like DOE-2 and EnergyPlus are tools that have been proven to aid with energy calculations to predict energy use in buildings. Some inputs to energy simulation models are relatively easy to find, including building size, orientation, construction materials, and HVAC system size and type. Others vary with time (e.g. weather and occupancy) and some can be a challenge to estimate in order to create an accurate simulation. In this paper, the analysis of occupancy sensor data for a large commercial, multi-tenant office building is presented. It details occupancy diversity factors for private offices and summarizes the same for open offices, hallways, conference rooms, break rooms, and restrooms in order to better inform energy simulation parameters. Long-term data were collected allowing results to be presented to show variations of occupancy diversity factors in private offices for time of day, day of the week, holidays, and month of the year. The diversity factors presented differ as much as 46% from those currently published in ASHRAE 90.1 2004 energy cost method guidelines, a document referenced by energy modelers regarding occupancy diversity factors for simulations. This may result in misleading simulation results and may introduce inefficiencies in the final equipment and systems design.

  11. Occupational ALARA Program Guide for Use with Title 10, CFR, Part 835, Occupational Radiation Protection

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1999-03-17

    This Guide provides an acceptable methodology for establishing and operating an occupational "as low as is reasonably achievable" (ALARA) program that will comply with U.S. Department of Energy (DOE) requirements specified in Title 10 of the Code of Federal Regulations (CFR), Part 835, Occupational Radiation Protection (DOE 1998a), hereinafter referred to as 10 CFR 835. For completeness, this Guide also references detailed guidance provided in the DOE-STD-1098-99, RADIOLOGICAL CONTROL (DOE 1999a), hereinafter referred to as the RCS.

  12. 851 S.W. Sixth Avenue, Suite 1100 Telephone: 503-222-5161 Fax: 503-820-2370 Portland, Oregon 97204-1348 Toll free: 800-452-5161 Web site: www.nwcouncil.org

    E-Print Network [OSTI]

    -1348 Toll free: 800-452-5161 Web site: www.nwcouncil.org JUDI DANIELSON CHAIR Idaho TOM KARIER VICE 97204-1348 Toll free: 800-452-5161 Web site: www.nwcouncil.org JUDI DANIELSON CHAIR Idaho TOM KARIER

  13. Using an Occupant Energy Index for Achieving Zero Energy Homes 

    E-Print Network [OSTI]

    Dean, B.; Gamble, D.; Kaiser, D.; Meisegeier, D.

    2006-01-01

    efficient appliances and by using the appliances more or less than a typical occupant. This energy use that is currently not capable of being analyzed or tracked can have significant impact on the actual performance of a utility or government... produces power onsite. How much might energy consumption increase when occupants return to this home? Past research has demonstrated that occupant behavior can have dramatic impacts on energy consumption. Maintained interior temperatures...

  14. DOE 2008 Occupational Radiation Exposure October 2009

    SciTech Connect (OSTI)

    U.S. Department of Energy, Office of Health, Safety and Security

    2009-10-01

    A major priority of the U.S. Department of Energy (DOE) is to ensure the health, safety, and security of DOE employees, contractors, and subcontractors. The Office of Health, Safety and Security (HSS) provides the corporate-level leadership and strategic vision necessary to better coordinate and integrate health, safety, environment, security, enforcement, and independent oversight programs. One function that supports this mission is the DOE Corporate Operating Experience Program that provides collection, analysis, and dissemination of performance indicators, such as occupational radiation exposure information. This analysis supports corporate decision-making and synthesizes operational information to support continuous environment, safety, and health improvement across the DOE complex.

  15. Systems and methods for sensing occupancy

    DOE Patents [OSTI]

    Dasu, Aravind; Mathias, Dean; Liu, Chenguang; Christensen, Randy; Christensen, Bruce

    2014-09-09

    A computer implemented method for sensing occupancy of a workspace includes creating a difference image that represents luminance differences of pixels in past and current images of the workspace resulting from motion in the workspace, determining motion occurring in regions of the workspace based on the difference image, and altering a workspace environment based at least in part on the determined motion. The method also includes determining which pixels in the difference image represent persistent motion that can be ignored and determining which pixels representing motion in the difference image are invalid because the pixels are isolated from other pixels representing motion.

  16. 2013 DOE Occupational Radiation Exposure Report Appendices

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i n c i p a l De p u t y A s s i sEnergy ItMisc. DOE Occupational Radiation

  17. Occupational Medicine Implications of Engineered Nanoscale Particulate Matter

    E-Print Network [OSTI]

    Kelly, Richard J.

    2008-01-01

    Ed. ) American Industrial Hygiene Association: 2008.occupational medicine and industrial hygiene is hampered byThe vast majority of industrial hygiene exposure limits for

  18. Weight Loss Convoy Year-Long Program - HPMC Occupational Health...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    RSVP Required-Space is limited. Class Instructors: Kelly Harnish & Audrey Wickman, Health Education Specialists Phone: 376-3939 Where: HPMC Occupational Medical Services, 1979...

  19. Fiscal Year 2013 Department of Energy Annual Occupational Safety...

    Office of Environmental Management (EM)

    Fiscal Year 2013 Department of Energy Annual Occupational Safety and Health Report for Federal Employees to the Secretary of Labor Fiscal Year 2013 Department of Energy Annual...

  20. PIA - Savannah River Nuclear Solution (SRNS) MedGate Occupational...

    Energy Savers [EERE]

    PIA - Savannah River Nuclear Solution (SRNS) MedGate Occupational Health and Safety Medical System (OHS) (Includes the Drug and Alcohol Testing System (Assistant)) PIA - Savannah...

  1. PIA - Savannah River Nuclear Solution (SRNS) MedGate Occupational...

    Energy Savers [EERE]

    MedGate Occupational Health and Safety Medical System (OHS) (Includes the Drug and Alcohol Testing System (Assistant)) PIA - Savannah River Nuclear Solution (SRNS) MedGate...

  2. Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants

    E-Print Network [OSTI]

    Konis, Kyle Stas

    2012-01-01

    Characterizing occupant behavior in buildings: Towards aoccupants or how occupant behavior affects the anticipatedEQ credit) compare with occupant behavior and subjective

  3. Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants

    E-Print Network [OSTI]

    Konis, Kyle Stas

    2011-01-01

    Characterizing occupant behavior in buildings: Towards aoccupants or how occupant behavior affects the anticipatedEQ credit) compare with occupant behavior and subjective

  4. Occupational safety and health law handbook

    SciTech Connect (OSTI)

    Sarvadi, D.G. [ed.; Keller; Heckman

    1999-09-01

    This book reviews the regulations and standards governing the protection of employees in the workplace and provides insight into dealing with pertinent regulations and regulatory authorities. Written for safety professionals, industrial hygienists, human resource professionals, attorneys, and students, this companion to Government Institutes' best-selling ``Environmental Law Handbook'' offers the legal fundamentals behind occupational safety and health laws in one concise and authoritative volume. In 19 chapters, the authoring law firm of Keller and Heckman cover the OSHAct and its development; OSHA, NIOSH, and OSHRC; the roles played by other regulatory agencies; the OSHA rulemaking process; OSHA Standards and the General Duty Clause; record keeping and reporting; employers' and employees' rights; inspections; violations, penalties, and how to contest them; criminal prosecutions; state plans; industry-specific issues; OSHA reform; and international regulations and standards. This book references approximately 400 seminal OSHA legal decisions from the approximately 1,300 cases on record and includes coverage of Canadian and European Community regulations, making it the first comprehensive global overview of occupational safety and health law.

  5. Occupancy Simulation in Three Residential Research Houses

    SciTech Connect (OSTI)

    Boudreaux, Philip R; Gehl, Anthony C; Christian, Jeffrey E

    2012-01-01

    Three houses of similar floor plan are being compared for energy consumption. The first house is a typical builder house of 2400 ft2 (223 m2) in east Tennessee. The second house contains retrofits available to a home owner such as energy efficient appliances, windows and HVAC, as well as an insulated attic which contains HVAC duct work. The third house was built using optimum-value framing construction with photovoltaic modules and solar water heating. To consume energy researchers have set up appliances, lights, and plug loads to turn on and off automatically according to a schedule based on the Building America Research Benchmark Definition. As energy efficiency continues to be a focus for protecting the environment and conserving resources, experiments involving whole house energy consumption will be done. In these cases it is important to understand how to simulate occupancy so that data represents only house performance and not human behavior. The process for achieving automated occupancy simulation will be discussed. Data comparing the energy use of each house will be presented and it will be shown that the third house used 66% less and the second house used 36% less energy than the control house in 2010. The authors will discuss how energy prudent living habits can further reduce energy use in the third house by 23% over the average American family living in the same house.

  6. DOE occupational radiation exposure 1996 report

    SciTech Connect (OSTI)

    1996-12-31

    The goal of the US Department of Energy (DOE) is to conduct its radiological operations to ensure the health and safety of all DOE employees including contractors and subcontractors. The DOE strives to maintain radiation exposures to its workers below administrative control levels and DOE limits and to further reduce these exposures and releases to levels that are ``As Low As Reasonably Achievable`` (ALARA). The DOE Occupational Radiation Exposure Report, 1996 provides summary and analysis of the occupational radiation exposure received by individuals associated with DOE activities. The DOE mission includes stewardship of the nuclear weapons stockpile and the associated facilities, environmental restoration of DOE and precursor agency sites, and energy research. Collective exposure at DOE has declined by 80% over the past decade due to a cessation in opportunities for exposure during the transition in DOE mission from weapons production to cleanup, deactivation and decommissioning, and changes in reporting requirements and dose calculation methodology. In 1996, the collective dose decreased by 10% from the 1995 value due to decreased doses at five of the seven highest-dose DOE sites. For 1996, these sites attributed the reduction in collective dose to the completion of several decontamination and decommissioning projects, reduced spent fuel storage activities, and effective ALARA practices. This report is intended to be a valuable tool for managers in their management of radiological safety programs and commitment of resources.

  7. Towards Building Occupants Positioning: Track and Trace for Optimal Process Control 

    E-Print Network [OSTI]

    Zeiler, W.; Labeodan, T.; Bozem, G.; Maaijen, R.

    2013-01-01

    Building occupancy information is a crucial factor that should be considered in the control strategy of building operations for improved energy efficiency and occupant comfort. As occupancy is stochastic and challenging to measure, a number of real...

  8. A social demographic study of the likelihood of sustaining an occupational fatality resulting in death 

    E-Print Network [OSTI]

    Traut, Rachel Lynn

    2009-05-15

    This thesis explores occupational fatalities to American males for the years 1998 and 1999. The focus is on predicting the likelihood that the individual will sustain an occupational injury resulting in death based on an occupational status score...

  9. Commercial Office Plug Load Energy Consumption Trends and the Role of Occupant Behavior

    E-Print Network [OSTI]

    Gandhi, Priya

    2015-01-01

    of adaptive occupant behaviors in offices. Building andDefinition and Simulation of Occupant Behavior in Buildings.and the Role of Occupant Behavior By Priya Bipin Gandhi A

  10. A technical framework to describe occupant behavior for building energy simulations

    SciTech Connect (OSTI)

    Turner , William; Hong , Tianzhen

    2013-12-20

    Green buildings that fail to meet expected design performance criteria indicate that technology alone does not guarantee high performance. Human influences are quite often simplified and ignored in the design, construction, and operation of buildings. Energy-conscious human behavior has been demonstrated to be a significant positive factor for improving the indoor environment while reducing the energy use of buildings. In our study we developed a new technical framework to describe energy-related human behavior in buildings. The energy-related behavior includes accounting for individuals and groups of occupants and their interactions with building energy services systems, appliances and facilities. The technical framework consists of four key components: i. the drivers behind energy-related occupant behavior, which are biological, societal, environmental, physical, and economical in nature ii. the needs of the occupants are based on satisfying criteria that are either physical (e.g. thermal, visual and acoustic comfort) or non-physical (e.g. entertainment, privacy, and social reward) iii. the actions that building occupants perform when their needs are not fulfilled iv. the systems with which an occupant can interact to satisfy their needs The technical framework aims to provide a standardized description of a complete set of human energy-related behaviors in the form of an XML schema. For each type of behavior (e.g., occupants opening/closing windows, switching on/off lights etc.) we identify a set of common behaviors based on a literature review, survey data, and our own field study and analysis. Stochastic models are adopted or developed for each type of behavior to enable the evaluation of the impact of human behavior on energy use in buildings, during either the design or operation phase. We will also demonstrate the use of the technical framework in assessing the impact of occupancy behavior on energy saving technologies. The technical framework presented is part of our human behavior research, a 5-year program under the U.S. - China Clean Energy Research Center for Building Energy Efficiency.

  11. This sheet has sample occupations, work settings, employers, and career development activities associated with this major. Some of these options may require additional training and career planning. You are not limited to these options when choosing a poss

    E-Print Network [OSTI]

    Ronquist, Fredrik

    Metropolitan Opera House New York Philharmonic Florida Music Educators' Association Sample Occupations Video Director Alternative Format Available · Revised 3/14 Connecting Majors, Skills, and Occupations...............................................IIB 27-2012.02 F5 Careers for High Energy People & Other Go

  12. U.S. Department of Labor Occupational Safety & Health Administration

    E-Print Network [OSTI]

    U.S. Department of Labor Occupational Safety & Health Administration www.osha.gov MyOSHA [skip with the background and experience to review such potential contamination and risk, in accordance

  13. Job Title: Occupational Health Nurse Department: Human Resources

    E-Print Network [OSTI]

    Saskatchewan, University of

    and/or evaluation of a variety of wellness programs and injury, illness, and disease prevention program, medical surveillance and immunization, ergonomics, and occupational health and safety initiatives. Continuously evaluate the early intervention and case management strategies, ensuring resources

  14. A Basic Overview of the Occupational Radiation Exposure Monitoring...

    Energy Savers [EERE]

    levels of risk similar to those for industrial activities (e.g., chemical, mining, transportation). The key U.S. limit for occupational exposure to radiation is 5 rems...

  15. DOE occupational radiation exposure. Report 1992--1994

    SciTech Connect (OSTI)

    1997-05-01

    The DOE Occupational Radiation Exposure Report, 1992-1994 reports occupational radiation exposures incurred by individuals at US Department of Energy (DOE) facilities from 1992 through 1994. This report includes occupational radiation exposure information for all DOE employees, contractors, subcontractors, and visitors. This information is analyzed and trended over time to provide a measure of the DOE`s performance in protecting its workers from radiation. Occupational radiation exposure at DOE has been decreasing over the past 5 years. In particular, doses in the higher dose ranges are decreasing, including the number of doses in excess of the DOE limits and doses in excess of the 2 rem Administrative Control Level (ACL). This is an indication of greater attention being given to protecting these individuals from radiation in the workplace.

  16. Behavioral Assessment of Occupational Skills of Learning Disabled Adolescents

    E-Print Network [OSTI]

    Mathews, R. Mark; Whang, Paula L.; Fawcett, Stephen B.

    1980-01-01

    This study, using direct observation and measurement techniques, analyzed the differences in occupational skills among learning disabled youths and their non-learning disabled peers . The results showed low levels of ...

  17. In-situ measurement of electrodermal activity during occupational therapy

    E-Print Network [OSTI]

    Hedman, Elliott B. (Elliot Bruce)

    2010-01-01

    Physiological arousal is an important part of occupational therapy for children with Sensory Processing Disorder (SPD) but therapists do not have a way to objectively measure how therapy affects arousal. We hypothesized ...

  18. 851 S.W. Sixth Avenue, Suite 1100 Telephone: 503-222-5161 Fax: 503-820-2370 Portland, Oregon 97204-1348 Toll free: 800-452-5161 Web site: www.nwcouncil.org

    E-Print Network [OSTI]

    -1348 Toll free: 800-452-5161 Web site: www.nwcouncil.org JUDI DANIELSON CHAIR Idaho MELINDA S. EDEN VICE be found on the Council's web site www.nwcouncil.org . The Council invites comment on this issue paper

  19. Occupation number-based energy functional for nuclear masses

    E-Print Network [OSTI]

    M. Bertolli; T. Papenbrock; S. Wild

    2011-10-19

    We develop an energy functional with shell-model occupations as the relevant degrees of freedom and compute nuclear masses across the nuclear chart. The functional is based on Hohenberg-Kohn theory with phenomenologically motivated terms. A global fit of the 17-parameter functional to nuclear masses yields a root-mean-square deviation of \\chi = 1.31 MeV. Nuclear radii are computed within a model that employs the resulting occupation numbers.

  20. PHYSICAL EXAM FORM FOR HEALTH OCCUPATIONS PROGRAMS

    E-Print Network [OSTI]

    Ward, Karen

    fever Chest pains/pressure Asthma Chronic cough Allergies to: (list) High blood pressure Rheumatic fever

  1. Examination of the Influence of Same-Race Occupational Role Models and Occupational Stereotypes on Elementary-Aged Black Students' School Engagement. 

    E-Print Network [OSTI]

    Moore, Karlen Brook

    2011-10-21

    Oppositional Culture Theory and Social Cognitive Career Theory propositions were explored via employment of social cognitive career theory mechanisms. The effects of observed same-race occupational role models and occupational stereotypes...

  2. EditEd by Tony Hey, STewarT TanSley, and KriSTin Tolle F o u r t h

    E-Print Network [OSTI]

    Narasayya, Vivek

    EditEd by Tony Hey, STewarT TanSley, and KriSTin Tolle The F o u r t h P a r a d i g m Data-IntensIve scIentIfIc DIscovery #12;#12;T HE Fou rT H Pa radigm #12;#12;EDITED BY Tony Hey, STewarT Tan foreword Gordon Bell xvii jim gray on escience: a transformed scientific method Edited by Tony Hey, Stewart

  3. Functional Toll-like receptor 4 expressed in lactotrophs mediates LPS-induced proliferation in experimental pituitary hyperplasia

    SciTech Connect (OSTI)

    Sabatino, María Eugenia; Sosa, Liliana del Valle; Petiti, Juan Pablo; Mukdsi, Jorge Humberto; Mascanfroni, Iván Darío; Pellizas, Claudia Gabriela; Gutiérrez, Silvina; Torres, Alicia Inés; De Paul, Ana Lucía

    2013-11-15

    Toll like receptor 4 (TLR4) has been characterized for its ability to recognize bacterial endotoxin lipopolysaccharide (LPS). Considering that infections or inflammatory processes might contribute to the progression of pituitary tumors, we analyzed the TLR4 functional role by evaluating the LPS effect on lactotroph proliferation in primary cultures from experimental pituitary tumors, and examined the involvement of PI3K-Akt and NF-?B activation in this effect. In addition, the role of 17?-estradiol as a possible modulator of LPS-induced PRL cell proliferation was further investigated. In estrogen-induced hyperplasic pituitaries, LPS triggered lactotroph cell proliferation. However, endotoxin failed to increase the number of lactotrophs taking up BrdU in normal pituitaries. Moreover, incubation with anti-TLR4 antibody significantly reduced LPS-induced lactotroph proliferation, suggesting a functional role of this receptor. As a sign of TLR4 activation, an LPS challenge increased IL-6 release in normal and tumoral cells. By flow cytometry, TLR4 baseline expression was revealed at the plasma membrane of tumoral lactotrophs, without changes noted in the percentage of double PRL/TLR4 positive cells after LPS stimulus. Increases in TLR4 intracellular expression were detected as well as rises in CD14, p-Akt and NF-?B after an LPS challenge, as assessed by western blotting. The TLR4/PRL and PRL/NF-?B co-localization was also corroborated by immunofluorescence and the involvement of PI3K/Akt signaling in lactotroph proliferation and IL-6 release was revealed through the PI3K inhibitor Ly-294002. In addition, 17?-estradiol attenuated the LPS-evoked increase in tumoral lactotroph proliferation and IL-6 release. Collectively these results demonstrate the presence of functional TLR4 in lactotrophs from estrogen-induced hyperplasic pituitaries, which responded to the proliferative stimulation and IL-6 release induced by LPS through TLR4/CD14, with a contribution of the PI3K-Akt and NF-?B signaling pathways. - Highlights: • In hyperplastic pituitaries, LPS triggered the lactotroph cell proliferation and IL-6 release. • Functional Toll-like receptor 4 (TLR4) is expressed at the plasma membrane of tumoral lactotrophs. • Increases in TLR4 and CD14 intracellular expression levels were detected after an LPS challenge. • The proliferative stimulation and IL-6 release involved the PI3K-Akt pathway and NF-?B activation. • 17?-estradiol attenuated the LPS-evoked tumoral lactotroph proliferation and IL-6 secretion.

  4. The Advantage of Highly Controlled Lighting for Offices and Commercial Buildings

    E-Print Network [OSTI]

    Rubinstein, Francis

    2010-01-01

    of Highly Controlled Lighting for Offices and Commercialefficient, customized lighting for open-office cubicles.s “ambient” and “task” lighting components, 2) occupancy

  5. Behavioral Health Services - HPMC Occupational Health Services

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    counseling; screening of personnel who work in high-risk, secure positions; fitness-for-duty evaluations; assessment and monitoring of substance abuse; and psychological...

  6. The Role of Occupant Behavior in Achieving Net Zero Energy: A Demonstration Project at Fort Carson

    SciTech Connect (OSTI)

    Judd, Kathleen S.; Sanquist, Thomas F.; Zalesny, Mary D.; Fernandez, Nicholas

    2013-09-30

    This study, sponsored by the U.S. General Services Administration’s Office of Federal High-Performance Green Buildings, aimed to understand the potential for institutional and behavioral change to enhance the performance of buildings, through a demonstration project with the Department of Defense in five green buildings on the Fort Carson, Colorado, Army base. To approach this study, the research team identified specific occupant behaviors that had the potential to save energy in each building, defined strategies that might effectively support behavior change, and implemented a coordinated set of actions during a three-month intervention.

  7. Detecting and tracing building occupants to optimize process control 

    E-Print Network [OSTI]

    Zeiler,W.; Labeodan,T.; Boxem,G.

    2014-01-01

    Building Operations, Beijing, China, September 14-17, 2014 PAGE 1 Workspace (micro climate) Human in the loop approach ESL-IC-14-09-29a Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014... Occupancy profile PAGE 211-11-2014 ESL-IC-14-09-29a Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 Drawbacks of Traditional-BEMS Comfort Time ? Operation based on assumed occupancy...

  8. Ambulatory infusion suite: pre- and post-occupancy evaluation 

    E-Print Network [OSTI]

    Shepley, Mardelle McCuskey; Rybkowski, Zofia; Aliber, Jennifer; Lange, Cathleen

    2015-02-08

    dans ce contexte. Mots cle´s: e´tablissement de lutte contre le cancer, e´valuation d’e´tablissement, soins de sante´, centre de perfusion, occupation, vie prive´e, interaction sociale Introduction This study focuses on an evaluation of infusion suites... facility, facility evaluation, healthcare, infusion suite, post-occupancy, privacy, social interaction Il est pre´sente´ une e´valuation de l’expe´rience ve´cue par les patients, les familles et les employe´s dans deux centres de perfusion. L’un des centres...

  9. Beyond occupational differences : the importance of cross-cutting demographics and dyadic toolkits for collaboration in a US hospital

    E-Print Network [OSTI]

    DiBenigno, Julia Marie

    2014-01-01

    Scholars of work and occupations have long shown that asking members from different occupations to collaborate with one another is difficult because of differences in status, meanings, and expertise across occupational ...

  10. Dysregulated Toll-like receptor expression and signaling in bone marrow-derived macrophages at

    E-Print Network [OSTI]

    Toledo, University of

    . Expression of TLR3 and TLR5 was significantly higher in newly diabetic non-obese diabetic (NOD) mice when-regulation of its own receptor in NOR and pre-diabetic NOD, but TLR3 was already highly expressed in diabetic NOD down-regulation of TLR4 in pre-diabetic NOD, NOR and BALB/c, while levels of TLR4 remained consistently

  11. The occupational status of partnered lesbians, compared to married women and heterosexual cohabiting women 

    E-Print Network [OSTI]

    Lin, Chin-Huei

    2009-05-15

    This thesis utilizes a regression model and three different occupational status scores, namely, Duncan‘s SEI, Nam-Powers-Boyd Occupational Status Score and Prestige Score of Nakao and Treas, to examine the impact of sexual ...

  12. Zoning and occupancy-moderation for residential space-conditioning under demand-driven electricity pricing

    E-Print Network [OSTI]

    Leow, Woei Ling, 1977-

    2012-01-01

    Occupancy-moderated zonal space-conditioning (OZS) refers to the partitioning of a residence into different zones and independently operating the space-conditioning equipment of each zone based on its occupancy. OZS remains ...

  13. Growing a green job : essays on social movements and the emergence of a new occupation

    E-Print Network [OSTI]

    Hammond, Ryan Alan

    2012-01-01

    Professions and occupations play a central role in shaping institutional arrangements, organizational forms, and individual organizations. I argue the emergence and development of new occupations should be among the central ...

  14. Program for Maintaining Occupational Radiation Exposure at Medical Institutions ALARA

    E-Print Network [OSTI]

    Hammack, Richard

    Program for Maintaining Occupational Radiation Exposure at Medical Institutions ALARA ALARA Program as low as is reasonably achievable (ALARA). In accord with this commitment, we hereby describe, and instructions to foster the ALARA concept within our institution. The organization will include a Radiation

  15. Occupational Health and Safety Checklist Home Based Work

    E-Print Network [OSTI]

    Tobar, Michael

    Occupational Health and Safety Checklist Home Based Work (to be completed by the Applicant) SAFETY RISK REQUIREMENTS COMMENTS Computer workstation Ensure appropriate workstation ergonomics, including as a result of computer use. Manual handling Know correct manual handling techniques. Know risks associated

  16. MODELING COUNT DATA FROM MULTIPLE SENSORS: A BUILDING OCCUPANCY MODEL

    E-Print Network [OSTI]

    Ihler, Alexander

    MODELING COUNT DATA FROM MULTIPLE SENSORS: A BUILDING OCCUPANCY MODEL Jon Hutchins, Alexander Ihler using real data from a network of optical counting sensors in a campus building. Index Terms--- sensor Knowledge of the number of people in a building at a given time is crucial for applications

  17. MODELING COUNT DATA FROM MULTIPLE SENSORS: A BUILDING OCCUPANCY MODEL

    E-Print Network [OSTI]

    Ihler, Alexander

    MODELING COUNT DATA FROM MULTIPLE SENSORS: A BUILDING OCCUPANCY MODEL Jon Hutchins, Alexander Ihler using real data from a network of optical counting sensors in a campus building. Index Terms-- sensor Knowledge of the number of people in a building at a given time is crucial for applications

  18. Fact #613: March 8, 2010 Vehicle Occupancy Rates

    Broader source: Energy.gov [DOE]

    The average number of persons occupying a car is 1.59 and has not changed much since 1995. The largest increases from 1995 to 2009 have been in the occupancy rates for vans – from 2.07 to 2.35 –...

  19. Runway Occupancy Time Extraction and Analysis Using Surface Track Data

    E-Print Network [OSTI]

    Vkumar3@gmu.edu lsherry@gmu.edu Rafal Kicinger kicinger@metronaviation.com Center for Air Transportation's runway occupancy time would add another 1-1.5 movements per hour [at London47 #12;3 Heathrow]' [7] [2

  20. CRAD, Occupational Safety & Health- Idaho MF-628 Drum Treatment Facility

    Broader source: Energy.gov [DOE]

    A section of Appendix C to DOE G 226.1-2 "Federal Line Management Oversight of Department of Energy Nuclear Facilities." Consists of Criteria Review and Approach Documents (CRADs) used for a February 2006 Commencement of Operations assessment of the Occupational Safety and Industrial Hygiene programs at the MF-628 Drum Treatment Facility at the Idaho National Laboratory Advanced Mixed Waste Treatment Project.

  1. Parental occupational exposures and risk of childhood cancer: A review

    SciTech Connect (OSTI)

    O'Leary, L.M.; Hicks, A.M.; Peters, J.M.; London, S. (University of Southern California School of Medicine, Los Angeles (USA))

    1991-01-01

    The authors reviewed the literature in order to summarize the present knowledge on the association between parental occupational exposures to chemicals and the risk of childhood malignancy. The 32 studies pertaining to this topic were evaluated by considering various study qualities such as sample size, specificity of outcome, confounding, exposure specificity, and control selection. When evaluating the findings from any epidemiologic study, the potential sources of bias have to be considered. The selection of subjects, misclassification of exposure or outcome, and confounding from extraneous factors can contribute to a biased estimate of effect. Studies done to minimize these potential biases will be more valid, and these studies should be given the most weight when parental occupational exposures are evaluated as risk factors for childhood malignancy. We conclude that the preponderance of evidence supports the hypothesis that occupational exposure of parents to chemicals increases the risk of childhood malignancy. The parental occupational exposures implicated in childhood malignancy risk are exposure to chemicals including paints, petroleum products, solvents (especially chlorinated hydrocarbons) and pesticides, and exposure to metals. The available data do not allow the identification of specific etiologic agents within these categories of compounds. Future epidemiologic and toxicologic studies should be designed to pursue these leads. 49 references.

  2. DOE Basic Overview of Occupational Radiation Exposure_2011 pamphlet

    SciTech Connect (OSTI)

    ORAU

    2012-08-08

    This pamphlet focusses on two HSS activities that help ensure radiation exposures are accurately assessed and recorded, namely: 1) the quality and accuracy of occupational radiation exposure monitoring, and 2) the recording, reporting, analysis, and dissemination of the monitoring results. It is intended to provide a short summary of two specific HSS programs that aid in the oversight of radiation protection activities at DOE. The Department of Energy Laboratory Accreditation Program (DOELAP) is in place to ensure that radiation exposure monitoring at all DOE sites is precise and accurate, and conforms to national and international performance and quality assurance standards. The DOE Radiation Exposure Monitoring Systems (REMS) program provides for the collection, analysis, and dissemination of occupational radiation exposure information. The annual REMS report is a valuable tool for managing radiological safety programs and for developing policies to protect individuals from occupational exposure to radiation. In tandem, these programs provide DOE management and workers an assurance that occupational radiation exposures are accurately measured, analyzed, and reported.

  3. RESEARCH ARTICLE Open Access Occupational exposure to asbestos and lung

    E-Print Network [OSTI]

    Boyer, Edmond

    RESEARCH ARTICLE Open Access Occupational exposure to asbestos and lung cancer in men: evidence consistently demonstrated that workplace exposure to it increases the risk of developing lung cancer. Few of lung cancer, and 2,053 controls recruited from 8 Canadian provinces between 1994 and 1997. Self

  4. POEM: Power-efficient Occupancy-based Energy Management System

    E-Print Network [OSTI]

    Cerpa, Alberto E.

    is electrical energy [1]. Of this total, 50% of the energy consumed in buildings is used for heating, air-conditioningPOEM: Power-efficient Occupancy-based Energy Management System Varick L. Erickson Elect. Eng for Heating Ventilation and Air-Conditioning (HVAC) systems. Current HVAC systems only condition based

  5. Occupancy Based Demand Response HVAC Control Strategy Varick L. Erickson

    E-Print Network [OSTI]

    Cerpa, Alberto E.

    Occupancy Based Demand Response HVAC Control Strategy Varick L. Erickson University of California an efficient demand response HVAC control strategy, actual room usage must be considered. Temperature and CO2 are used for simulations but not for predictive demand response strategies. In this paper, we develop

  6. CRAD, Occupational Safety & Health- Idaho Accelerated Retrieval Project Phase II

    Broader source: Energy.gov [DOE]

    A section of Appendix C to DOE G 226.1-2 "Federal Line Management Oversight of Department of Energy Nuclear Facilities." Consists of Criteria Review and Approach Documents (CRADs) used for a February 2006 Commencement of Operations assessment of the Occupational Safety and Industrial Hygiene Program at the Idaho Accelerated Retrieval Project Phase II.

  7. "Designing equipment and buildings to more quickly respond to occupant

    E-Print Network [OSTI]

    Zhigilei, Leonid V.

    prediction system Energy Efficient Smart Buildings In the near future, intelligent buildings"Designing equipment and buildings to more quickly respond to occupant behavior." Kamin Whitehouse University of Virginia Charlottesville, VA 434.982.2211 Whitehouse Research Group Our group is creating smart

  8. Modeling Human Metabolism of Benzene Following Occupational and Environmental Exposures

    E-Print Network [OSTI]

    California at Berkeley, University of

    Modeling Human Metabolism of Benzene Following Occupational and Environmental Exposures Sungkyoon) models to investigate nonlinear relationships between levels of benzene metabolites (E,E- muconic acid, S-phenylmercapturic acid, phenol, hydroqui- none, and catechol) and benzene exposure among 386 exposed and control workers

  9. Energy Savings for Occupancy-Based Control (OBC) of Variable-Air-Volume (VAV) Systems

    SciTech Connect (OSTI)

    Zhang, Jian; Lutes, Robert G.; Liu, Guopeng; Brambley, Michael R.

    2013-01-24

    This study evaluates the savings potential of occupancy based control (OBC) for large office buildings with VAV terminal boxes installed.

  10. Occupancy Agreement *This Facility is partially funded through the Federal Government

    E-Print Network [OSTI]

    10893605_1 Occupancy Agreement *This Facility is partially funded through the Federal Government 6 9. Termination by the Occupant 6 10. Default by Occupant and Notice 7 11. Privacy 7 11 accepts the terms and conditions contained in the letter of offer. Termination Date The date contained

  11. Critical residues involved in Toll-like receptor 4 activation by cationic lipid nanocarriers are not located at the lipopolysaccharide-binding interface

    E-Print Network [OSTI]

    Lonez, Caroline; Irvine, Kate L.; Pizzuto, Malvina; Schmidt, Boris I.; Gay, Nick J.; Ruysschaert, Jean-Marie; Gangloff, Monique; Bryant, Clare E.

    2015-05-09

    -1970. doi: 10.1016/j.bcp.2007.03.006 36 22 43. Kedmi,R, Ben-Arie,N, Peer,D (2010). The systemic toxicity of positively charged lipid 1 nanoparticles and the role of Toll-like receptor 4 in immune activation. Biomaterials 31: 6867-2 6875. doi: 10... .1016/j.biomaterials.2010.05.027 3 44. Uto,T, Akagi,T, Yoshinaga,K, Toyama,M, Akashi,M, Baba,M (2011). The induction of innate 4 and adaptive immunity by biodegradable poly(gamma-glutamic acid) nanoparticles via a 5 TLR4 and MyD88 signaling pathway...

  12. IMAGE PROCESSING OCCUPANCY SENSOR - Energy Innovation Portal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration would likeUniverse (JournalvivoHighHussein KhalilResearch8 IEEE TRANSACTIONSIII .. III A/ W

  13. Screening values for Non-Carcinogenic Hanford Waste Tank Vapor Chemicals that Lack Established Occupational Exposure Limits

    SciTech Connect (OSTI)

    Poet, Torka S.; Mast, Terryl J.; Huckaby, James L.

    2006-02-06

    Over 1,500 different volatile chemicals have been reported in the headspaces of tanks used to store high-level radioactive waste at the U.S. Department of Energy's Hanford Site. Concern about potential exposure of tank farm workers to these chemicals has prompted efforts to evaluate their toxicity, identify chemicals that pose the greatest risk, and incorporate that information into the tank farms industrial hygiene worker protection program. Established occupation exposure limits for individual chemicals and petroleum hydrocarbon mixtures have been used elsewhere to evaluate about 900 of the chemicals. In this report headspace concentration screening values were established for the remaining 600 chemicals using available industrial hygiene and toxicological data. Screening values were intended to be more than an order of magnitude below concentrations that may cause adverse health effects in workers, assuming a 40-hour/week occupational exposure. Screening values were compared to the maximum reported headspace concentrations.

  14. Occupancy by key transcription factors is a more accurate predictor of enhancer activity than histone modifications or chromatin accessibility

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Dogan, Nergiz; Wu, Weisheng; Morrissey, Christapher S.; Chen, Kuan-Bei; Stonestrom, Aaron; Long, Maria; Keller, Cheryl A.; Cheng, Yong; Jain, Deepti; Visel, Axel; et al

    2015-04-23

    Regulated gene expression controls organismal development, and variation in regulatory patterns has been implicated in complex traits. Thus accurate prediction of enhancers is important for further understanding of these processes. Genome-wide measurement of epigenetic features, such as histone modifications and occupancy by transcription factors, is improving enhancer predictions, but the contribution of these features to prediction accuracy is not known. Given the importance of the hematopoietic transcription factor TAL1 for erythroid gene activation, we predicted candidate enhancers based on genomic occupancy by TAL1 and measured their activity. Contributions of multiple features to enhancer prediction were evaluated based on the resultsmore »of these and other studies. Results: TAL1-bound DNA segments were active enhancers at a high rate both in transient transfections of cultured cells (39 of 79, or 56%) and transgenic mice (43 of 66, or 65%). The level of binding signal for TAL1 or GATA1 did not help distinguish TAL1-bound DNA segments as active versus inactive enhancers, nor did the density of regulation-related histone modifications. A meta-analysis of results from this and other studies (273 tested predicted enhancers) showed that the presence of TAL1, GATA1, EP300, SMAD1, H3K4 methylation, H3K27ac, and CAGE tags at DNase hypersensitive sites gave the most accurate predictors of enhancer activity, with a success rate over 80% and a median threefold increase in activity. Chromatin accessibility assays and the histone modifications H3K4me1 and H3K27ac were sensitive for finding enhancers, but they have high false positive rates unless transcription factor occupancy is also included. Conclusions: Occupancy by key transcription factors such as TAL1, GATA1, SMAD1, and EP300, along with evidence of transcription, improves the accuracy of enhancer predictions based on epigenetic features.« less

  15. The Santa Clara Valley R & D Dillema: The Real Estate Industry and High Tech Growth

    E-Print Network [OSTI]

    Kroll, Cynthia A.; Kimball, Linda M.

    1986-01-01

    Absorption . 57 VI. Evolving High Tech Demand for Space:Silicon Valley Job Growth within High Tech Sectors .. 64 TheOccupational Composition of High Tech Employment. 71 Santa

  16. Avoiding Sick Buildings while Assuring Occupant Productivity and Building Optimization 

    E-Print Network [OSTI]

    Int-Hout, D.

    2002-01-01

    of diffusers is necessary to ensure that both occupant comfort and adequate ventilation mixing are provided. As the choice of diffusers is based on both engineering and architectural concerns, both the engineer and the architect need to have input... into the final selection. In addition, the ideal selection is dependent on the type and operation of the air supply to the diffuser. While there are many ways of supplying conditioned air to an office space including displacement ventilation, underfloor...

  17. Occupational Radiation Protection Record-Keeping and Reporting Guide for use with Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1999-05-20

    This Guide provides an acceptable methodology for establishing and operating an occupational radiation protection record-keeping and reporting program that will comply with U.S. Department of Energy (DOE) requirements specified in Title 10 of the Code of Federal Regulations (CFR), Part 835, Occupational Radiation Protection. Canceled by DOE G 441.1-1B.

  18. Ask us: education.library@queensu.ca or 613-533-2191 or toll free 1-866-267-7406 Last updated: 31 January 2015 Resources for PJ Science Lesson Planning

    E-Print Network [OSTI]

    Fletcher, Robin

    January 2015 Resources for PJ Science Lesson Planning @ Queen's U Education Library Find books: http Resource Bank Ontario Ministry of Education http://resources.elearningontario.ca There are sample resourcesAsk us: education.library@queensu.ca or 613-533-2191 or toll free 1-866-267-7406 Last updated: 31

  19. Comparison of Salivary and Serum Levels of Soluble Toll-Like Receptor 3 (TLR3) in Patients with Sjögren's Syndrome (SS) Compared to Age- and Sex-Matched Controls 

    E-Print Network [OSTI]

    Parks, Harrison Lee

    2014-04-28

    This cross-sectional study examined potential differences in concentration of Toll-like receptor 3 (TLR3) in serum and citric acid-stimulated saliva from patients with Sjögren’s Syndrome (SS) and healthy age-, sex-, and periodontal disease- matched...

  20. Occupational Radiation Exposure at Commercial Nuclear Power Reactors and Other Facilities 2008

    SciTech Connect (OSTI)

    U.S. Nuclear Regulatory Commission, Office of Nuclear Regulatory Research

    2009-12-01

    This report summarizes the occupational exposure data that are maintained in the U.S. Nuclear Regulatory Commission (NRC) Radiation Exposure Information and Reporting System (REIRS). The bulk of the information contained in the report was compiled from the 2008 annual reports submitted by five of the seven categories1 of NRC licensees subject to the reporting requirements of 10 CFR 20.2206. The annual reports submitted by these licensees consist of radiation exposure records for each monitored individual. These records are analyzed for trends and presented in this report in terms of collective dose and the distribution of dose among the monitored individuals. Because there are no geologic repositories for high-level waste currently licensed and no low-level waste disposal facilities in operation, only five categories will be considered in this report.

  1. Annual DOE Occupational Radiation Exposure | 1998 Report | Department of

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i n c i p a l De p u t yWaste | Department ofEnergy reports occupational

  2. Annual DOE Occupational Radiation Exposure | 2002 Report | Department of

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i n c i p a l De p u t yWaste | Department ofEnergyEnergy Occupational

  3. Annual DOE Occupational Radiation Exposure | 2006 Report | Department of

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i n c i p a l De p u t yWaste | DepartmentEnergy Occupational Radiation

  4. Annual DOE Occupational Radiation Exposure | 2007 Report | Department of

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i n c i p a l De p u t yWaste | DepartmentEnergy Occupational

  5. Annual DOE Occupational Radiation Exposure | 2008 Report | Department of

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i n c i p a l De p u t yWaste | DepartmentEnergy OccupationalEnergy

  6. Use of Occupancy Sensors in LED Parking Lot and Garage Applications...

    Office of Scientific and Technical Information (OSTI)

    Experiences Kinzey, Bruce R.; Myer, Michael; Royer, Michael P.; Sullivan, Greg P. LED lighting; parking lot lighting; occupancy sensors LED lighting; parking lot lighting;...

  7. Collecting Occupant Presence Data for Use in Energy Management of Commercial Buildings

    E-Print Network [OSTI]

    Rosenblum, Benjamin Tarr

    2012-01-01

    types that are most useful in energy analysis integratedto provide occupant data useful for energy management. Founddiscuss what data are useful to specific energy management

  8. Low-cost coarse airborne particulate matter sensing for indoor occupancy detection

    E-Print Network [OSTI]

    Weekly, Kevin

    2013-01-01

    the energy-efficient smart building, occupancy detection andare being added to smart buildings to ensure the quality ofvaluable information for smart buildings. An important next

  9. Statistical Analysis and Modeling of Occupancy Patterns in Open-Plan Offices using Measured Lighting-Switch Data

    SciTech Connect (OSTI)

    Chang, Wen-Kuei; Hong, Tianzhen

    2013-01-01

    Occupancy profile is one of the driving factors behind discrepancies between the measured and simulated energy consumption of buildings. The frequencies of occupants leaving their offices and the corresponding durations of absences have significant impact on energy use and the operational controls of buildings. This study used statistical methods to analyze the occupancy status, based on measured lighting-switch data in five-minute intervals, for a total of 200 open-plan (cubicle) offices. Five typical occupancy patterns were identified based on the average daily 24-hour profiles of the presence of occupants in their cubicles. These statistical patterns were represented by a one-square curve, a one-valley curve, a two-valley curve, a variable curve, and a flat curve. The key parameters that define the occupancy model are the average occupancy profile together with probability distributions of absence duration, and the number of times an occupant is absent from the cubicle. The statistical results also reveal that the number of absence occurrences decreases as total daily presence hours decrease, and the duration of absence from the cubicle decreases as the frequency of absence increases. The developed occupancy model captures the stochastic nature of occupants moving in and out of cubicles, and can be used to generate a more realistic occupancy schedule. This is crucial for improving the evaluation of the energy saving potential of occupancy based technologies and controls using building simulations. Finally, to demonstrate the use of the occupancy model, weekday occupant schedules were generated and discussed.

  10. Occupational hygiene in terms of volatile organic compounds (VOCs) and bioaerosols at two solid waste management plants in Finland

    SciTech Connect (OSTI)

    Lehtinen, Jenni; Tolvanen, Outi; Nivukoski, Ulla; Veijanen, Anja; Hänninen, Kari

    2013-04-15

    Highlights: ? Odorous VOCs: acetic acid, 2,3-butanedione, ethyl acetate, alpha-pinene and limonene. ? VOC concentrations did not exceed occupational exposure limit concentrations. ? 2,3-Butanedione as the health effecting compound is discussed. ? Endotoxin concentrations may cause health problems in waste treatment. - Abstract: Factors affecting occupational hygiene were measured at the solid waste transferring plant at Hyvinkää and at the optic separation plant in Hämeenlinna. Measurements consisted of volatile organic compounds (VOCs) and bioaerosols including microbes, dust and endotoxins. The most abundant compounds in both of the plants were aliphatic and aromatic hydrocarbons, esters of carboxylic acids, ketones and terpenes. In terms of odour generation, the most important emissions were acetic acid, 2,3-butanedione, ethyl acetate, alpha-pinene and limonene due to their low threshold odour concentrations. At the optic waste separation plant, limonene occurred at the highest concentration of all single compounds of identified VOCs. The concentration of any single volatile organic compound did not exceed the occupational exposure limit (OEL) concentration. However, 2,3-butanedione as a health risk compound is discussed based on recent scientific findings linking it to lung disease. Microbe and dust concentrations were low at the waste transferring plant. Only endotoxin concentrations may cause health problems; the average concentration inside the plant was 425 EU/m{sup 3} which clearly exceeded the threshold value of 90 EU/m{sup 3}. In the wheel loader cabin the endotoxin concentrations were below 1 EU/m{sup 3}. High microbial and endotoxin concentrations were measured in the processing hall at the optic waste separation plant. The average concentration of endotoxins was found to be 10,980 EU/m{sup 3}, a concentration which may cause health risks. Concentrations of viable fungi were quite high in few measurements in the control room. The most problematic factor was endotoxins whose average measured concentrations was 4853 EU/m{sup 3}.

  11. Occupational radiation Exposure at Agreement State-Licensed Materials Facilities, 1997-2010

    SciTech Connect (OSTI)

    U.S. Nuclear Regulatory Commission, Office of Nuclear Regulatory Research

    2012-07-07

    The purpose of this report is to examine occupational radiation exposures received under Agreement State licensees. As such, this report reflects the occupational radiation exposure data contained in the Radiation Exposure Information and Reporting System (REIRS) database, for 1997 through 2010, from Agreement State-licensed materials facilities.

  12. DOE Issues Request for Proposals for Hanford Site Occupational Medical Services

    Broader source: Energy.gov [DOE]

    RICHLAND, Wash. – The Department of Energy (DOE) today issued a Request for Proposals (RFP) for an Occupational Medical Services contract at the Hanford Site. The solicitation is for a small-business contractor to perform occupational medical services for the DOE Richland Operations Office and Office of River Protection.

  13. Applied Occupational and Environmental Hygiene Volume 17(2): 121130, 2002

    E-Print Network [OSTI]

    Broday, David

    Industrial Hygiene 1047-322X/02 $12.00 + .00 Occupational Exposure to Cotton Dust in Cottonseed Oil MillsApplied Occupational and Environmental Hygiene Volume 17(2): 121­130, 2002 Copyright c 2002 Applied and cellulose industries. The cottonseed delivered to the mill is contaminated with varying amounts of trash

  14. New Findings on Using Queue Occupancy to Integrate Runtime Power-Saving Techniques Across the Pipeline

    E-Print Network [OSTI]

    Huang, Wei

    New Findings on Using Queue Occupancy to Integrate Runtime Power-Saving Techniques Across provides new insights on how to integrate power-saving techniques by using queue occupancies to dynamically match the power-saving modes of various pipeline stages with the current instruction throughput. (This

  15. The Application and Energy Savings Potential of Occupancy Counters/Transmitters in Office Buildings 

    E-Print Network [OSTI]

    Medlin, J. W.

    1987-01-01

    because the occupancy is below the design occupancy. In hot and humid climates, such as the Gulf Southwest, a considerable portion of the cooling energy in a commercial building is expended cooling and dehumidifying the air needed to maintain fresh air...

  16. Joint asymptotic behavior of local and occupation times of random walk in higher dimension

    E-Print Network [OSTI]

    Csáki, Endre

    Joint asymptotic behavior of local and occupation times of random walk in higher dimension Endre behavior of two objects: #28;rst the local times of a pair of neighboring points, then the local time of a point and the occupation time of the surface of the unit ball around it. AMS 2000 Subject Classi#28

  17. Pond age and riparian zone proximity influence anuran occupancy of urban retention ponds

    E-Print Network [OSTI]

    Dorcas, Michael E.

    Pond age and riparian zone proximity influence anuran occupancy of urban retention ponds Devynn A and negatively affects many wildlife populations. However, certain urban features, such as retention ponds, may proximity and pond age on retention pond occupancy by anurans. We identified and estimated the age of 25

  18. Financial Policy Manual 2317 PAYROLL, REAL ESTATE, SALES, USE AND OCCUPANCY AND

    E-Print Network [OSTI]

    George, Edward I.

    Financial Policy Manual Page 1 2317 PAYROLL, REAL ESTATE, SALES, USE AND OCCUPANCY AND UNRELATED and Occupancy Approved Supporting Schedules · Real Estate Municipal Tax Bills · Unrelated Business Income system for determining the accurate and complete amounts due for payroll, real estate, sales, use

  19. Environmental and Occupational Health BS, 2015-2016 Name ID# Date

    E-Print Network [OSTI]

    Barrash, Warren

    Environmental and Occupational Health BS, 2015-2016 Name ID# Date Course Number and Title Credits Communication 3 DLS ENVHLTH 102 Global Environmental Health 3 BIOL 192 or BIOL 228 Biology 4 BIOL 205 or BIOL Environmental Health Management 3 ENVHLTH 415 Occupational Safety and Health 3 ENVHLTH 416 Noise and Other

  20. Three essays in labor and health economics: individual decisions on occupation, labor supply, and demand for heatlh 

    E-Print Network [OSTI]

    Shin, Ja Eun

    2005-08-29

    In this dissertation, I examine individual decisions in occupational choice, labor supply, and health care utilization. Occupational choice decisions of female college graduates on whether to teach or not are analyzed to understand the role...

  1. Biokinetic data and models for occupational intake of lanthanoids

    SciTech Connect (OSTI)

    Leggett, Richard Wayne; Ansoborlo, Eric; Bailey, Dr. Michael; Gregoratto, Demetrio; Pacquet, Dr. Francois; Taylor, Dr. David

    2014-01-01

    The lanthanoid (or lanthanide) chemical elements comprise fifteen elements with atomic numbers 57 (lanthanum) through 71 (lutetium). This paper reviews data related to the biological behavior of these elements in the human body and proposes biokinetic models for application to occupational intake of radio-lanthanoids. Generic (element-independent) absorption rates from the respiratory and alimentary tracts to blood are proposed. The proposed systemic models are largely generic but include some element-specific parameter values to reflect regular changes with ionic radius in certain aspects of the behavior of the lanthanoids. This work was performed within the internal dosimetry task group (INDOS) of Committee 2 of the International Commission on Radiological Protection (ICRP).

  2. Occupational Radiation Exposure Analysis of US ITER DCLL TBM

    SciTech Connect (OSTI)

    Merrill, Brad J; Cadwallader, Lee C; Dagher, Mohamad

    2007-08-01

    This report documents an Occupational Radiation Exposure (ORE) analysis that was performed for the US International Thermonuclear Experimental Reactor (ITER) Dual Coolant Lead Lithium (DCLL) Test Blanket Module (TBM). This analysis was performed with the QADMOD dose code for anticipated maintenance activities for this TBM concept and its ancillary systems. The QADMOD code was used to model the PbLi cooling loop of this TBM concept by specifying gamma ray source terms that simulated radioactive material within the piping, valves, heat exchanger, permeator, pump, drain tank, and cold trap of this cooling system. Estimates of the maintenance tasks that will have to be performed and the time required to perform these tasks where developed based on either expert opinion or on industrial maintenance experience for similar technologies. This report details the modeling activity and the calculated doses for the maintenance activities envisioned for the US DCLL TBM.

  3. Stochastic Modeling of Overtime Occupancy and Its Application in Building Energy Simulation and Calibration

    SciTech Connect (OSTI)

    Sun, Kaiyu; Yan , Da; Hong , Tianzhen; Guo, Siyue

    2014-02-28

    Overtime is a common phenomenon around the world. Overtime drives both internal heat gains from occupants, lighting and plug-loads, and HVAC operation during overtime periods. Overtime leads to longer occupancy hours and extended operation of building services systems beyond normal working hours, thus overtime impacts total building energy use. Current literature lacks methods to model overtime occupancy because overtime is stochastic in nature and varies by individual occupants and by time. To address this gap in the literature, this study aims to develop a new stochastic model based on the statistical analysis of measured overtime occupancy data from an office building. A binomial distribution is used to represent the total number of occupants working overtime, while an exponential distribution is used to represent the duration of overtime periods. The overtime model is used to generate overtime occupancy schedules as an input to the energy model of a second office building. The measured and simulated cooling energy use during the overtime period is compared in order to validate the overtime model. A hybrid approach to energy model calibration is proposed and tested, which combines ASHRAE Guideline 14 for the calibration of the energy model during normal working hours, and a proposed KS test for the calibration of the energy model during overtime. The developed stochastic overtime model and the hybrid calibration approach can be used in building energy simulations to improve the accuracy of results, and better understand the characteristics of overtime in office buildings.

  4. Occupational exposures to uranium: processes, hazards, and regulations

    SciTech Connect (OSTI)

    Stoetzel, G.A.; Fisher, D.R.; McCormack, W.D.; Hoenes, G.R.; Marks, S.; Moore, R.H.; Quilici, D.G.; Breitenstein, B.D.

    1981-04-01

    The United States Uranium Registry (USUR) was formed in 1978 to investigate potential hazards from occupational exposure to uranium and to assess the need for special health-related studies of uranium workers. This report provides a summary of Registry work done to date. The history of the uranium industry is outlined first, and the current commercial uranium industry (mining, milling, conversion, enrichment, and fuel fabrication) is described. This description includes information on basic processes and areas of greatest potential radiological exposure. In addition, inactive commercial facilities and other uranium operations are discussed. Regulation of the commercial production industry for uranium fuel is reported, including the historic development of regulations and the current regulatory agencies and procedures for each phase of the industry. A review of radiological health practices in the industry - facility monitoring, exposure control, exposure evaluation, and record-keeping - is presented. A discussion of the nonradiological hazards of the industry is provided, and the final section describes the tissue program developed as part of the Registry.

  5. Occupant Evaluation of Leadership in Energy and Environmental Design (LEED) Certified Health Centers 

    E-Print Network [OSTI]

    Hill, Anorea M.

    2010-01-14

    satisfactory scores from the occupants. Within the case studies variations in satisfaction occurred where LEED points were not received. There is no evidence that perceivable features used in the design and construction of LEED certified health centers decrease...

  6. Integration by Parts on Wiener Space and the Existence of Occupation Densities

    E-Print Network [OSTI]

    Imkeller, Peter; Nualart, David

    1994-03-02

    We present a general criterion for the existence of an occupation density, which is based on the integration by parts formula on Wiener space. This criterion is applied to two particular examples of anticipating processes. First we discuss the case...

  7. Sentinel: Occupancy Based HVAC Actuation using Existing WiFi Infrastructure within Commercial Buildings

    E-Print Network [OSTI]

    Gupta, Rajesh

    , Control Keywords Sentinel, HVAC, occupancy, buildings, energy efficiency 1. INTRODUCTION Commercial.00. As a result, improving the energy-efficiency of building HVAC systems is key from both a cost saving

  8. Occupational Medicine Open House/Pre Tailgate Sept. 9 | The Ames...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    some new employees, the start of a new school year and the upcoming Iowa State-Iowa football game, Ames Lab's Occupation Medicine department is holding an open housePre Tailgate...

  9. Collecting Occupant Presence Data for Use in Energy Management of Commercial Buildings

    E-Print Network [OSTI]

    Rosenblum, Benjamin Tarr

    2012-01-01

    item/1pz2528w If energy consumption data are not availablewith both energy consumption data (in kWh or kBtu) andaffects energy consumption, and use occupant data to

  10. Introduction Occupational attainment is a central issue in discussions of female migration in

    E-Print Network [OSTI]

    Huang, Youqin

    access only limited resources and opportunities (Greenhalgh, 1985; Jacka, 1992). Economic reform has, and the occupational attainment of female migrants in China (1985 ^ 1990) Youqin Huang Department of Geography

  11. Occupational status orientations and perception of opportunity: A racial comparison of rural youth from depressed areas. 

    E-Print Network [OSTI]

    Ameen, Bilquis Ara

    1968-01-01

    OCCUPATIONAL STATUS ORIENTATIONS AND PERCEPTION OF OPPORTUNITY: A RACIAL COMPARISON OF RURAL YOUTH FROM DEPRESSED AREAS A Thesis BY BILQUIS A. AMEEN Submitted to the Graduate College of the Texas 'A&M University in partial fulfillment... of the requirements for the degree of January 1968 Major Subject: Sociology OCCUPATIONAL STATUS ORIENTATIONS AND PERCEPTION OF OPPORTUNITY: A RACIAL CCMPARISON CF RURAL YOUTH FROM DEPRESSED AREAS A Thesis BY BILQUIS A. AMER% Approved as to style and content...

  12. Indoor Air Quality in 24 California Residences Designed as High Performance Green Homes

    E-Print Network [OSTI]

    Less, Brennan

    2012-01-01

    Occupant Behavior ..commissioning and occupant behavior caused other potentialas an option for tracking occupant behavior, but they were

  13. Development and Field-Testing of a Study Protocol, including a Web-Based Occupant Survey Tool, for Use in Intervention Studies of Indoor Environmental Quality

    SciTech Connect (OSTI)

    Mendell, Mark; Eliseeva, Ekaterina; Spears, Michael; Fisk, William J.

    2009-06-01

    We developed and pilot-tested an overall protocol for intervention studies to evaluate the effects of indoor environmental changes in office buildings on the health symptoms and comfort of occupants. The protocol includes a web-based survey to assess the occupant's responses, as well as specific features of study design and analysis. The pilot study, carried out on two similar floors in a single building, compared two types of ventilation system filter media. With support from the building's Facilities staff, the implementation of the filter change intervention went well. While the web-based survey tool worked well also, low overall response rates (21-34percent among the three work groups included) limited our ability to evaluate the filter intervention., The total number of questionnaires returned was low even though we extended the study from eight to ten weeks. Because another simultaneous study we conducted elsewhere using the same survey had a high response rate (>70percent), we conclude that the low response here resulted from issues specific to this pilot, including unexpected restrictions by some employing agencies on communication with occupants.

  14. Occupational Exposure to Benzene from Painting with Epoxy and Other High Performance Coatings

    SciTech Connect (OSTI)

    JAHN, STEVEN

    2005-04-20

    Following the discovery of trace benzene in paint products, an assessment was needed to determine potential for benzene exposures to exceed the established ACGIH Threshold Limit Value (TLV) during painting operations. Sample data was collected by area industrial hygienists for benzene during routine maintenance and construction activities at Savannah River Site. A set of available data from the IH database, Sentry, was analyzed to provide guidance to the industrial hygiene staff and draw conclusions on the exposure potential during typical painting operations.

  15. Evaluating Air Quality Benefits of Freeway High-Occupancy Vehicle Lanes in Southern California

    E-Print Network [OSTI]

    Boriboonsomsin, K; Barth, M

    2007-01-01

    CO HC NOx CO2 Fuel (b) % difference in emission rates perNOx CO2 Fuel HOV lanes higher % Difference HOV lanes lower Scenario 1 Scenario 2 Scenario 3 Scenario 4 (a) % difference in emission

  16. Evaluating Air Quality Benefits of Freeway High-Occupancy Vehicle Lanes in Southern California

    E-Print Network [OSTI]

    Boriboonsomsin, K; Barth, M

    2007-01-01

    on Light-Duty Vehicle Emissions: Experimental Study withtheir impacts on vehicle emissions. Four general HOV laneand compared. Vehicle emissions and fuel consumption were

  17. A Review of High Occupancy Vehicle (HOV) Lane Performance and Policy

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX E LIST OFAMERICA'SHeavyAgencyTendo NewYanbu,Information on Worldwide HydrogenOptions

  18. Structure-Based Analysis of Toxoplasma gondii Profilin: A Parasite-Specific Motif Is Required for Recognition by Toll-Like Receptor 11

    SciTech Connect (OSTI)

    K Kucera; A Koblansky; L Saunders; K Frederick; E De La Cruz; S Ghosh; Y Modis

    2011-12-31

    Profilins promote actin polymerization by exchanging ADP for ATP on monomeric actin and delivering ATP-actin to growing filament barbed ends. Apicomplexan protozoa such as Toxoplasma gondii invade host cells using an actin-dependent gliding motility. Toll-like receptor (TLR) 11 generates an innate immune response upon sensing T. gondii profilin (TgPRF). The crystal structure of TgPRF reveals a parasite-specific surface motif consisting of an acidic loop, followed by a long {beta}-hairpin. A series of structure-based profilin mutants show that TLR11 recognition of the acidic loop is responsible for most of the interleukin (IL)-12 secretion response to TgPRF in peritoneal macrophages. Deletion of both the acidic loop and the {beta}-hairpin completely abrogates IL-12 secretion. Insertion of the T. gondii acidic loop and {beta}-hairpin into yeast profilin is sufficient to generate TLR11-dependent signaling. Substitution of the acidic loop in TgPRF with the homologous loop from the apicomplexan parasite Cryptosporidium parvum does not affect TLR11-dependent IL-12 secretion, while substitution with the acidic loop from Plasmodium falciparum results in reduced but significant IL-12 secretion. We conclude that the parasite-specific motif in TgPRF is the key molecular pattern recognized by TLR11. Unlike other profilins, TgPRF slows nucleotide exchange on monomeric rabbit actin and binds rabbit actin weakly. The putative TgPRF actin-binding surface includes the {beta}-hairpin and diverges widely from the actin-binding surfaces of vertebrate profilins.

  19. Discrete Li-occupation versus pseudo-continuous Na-occupation and their relationship with structural change behaviors in Fe?(MoO?)?

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Yue, Ji-Li; Zhou, Yong-Ning; Shi, Si-Qi; Shadike, Zulipiya; Huang, Xuan-Qi; Luo, Jun; Yang, Zhen-Zhong; Li, Hong; Gu, Lin; Yang, Xiao-Qing; et al

    2015-03-06

    The key factors governing the single-phase or multi-phase structural change behaviors during the intercalation/deintercalation of guest ions have not been well studied and understood yet. Through systematic studies of orthorhombic Fe?(MoO?)? electrode, two distinct guest ion occupation paths, namely discrete one for Li and pseudo-continuous one for Na, as well as their relationship with single-phase and two-phase modes for Na? and Li?, respectively during the intercalation/deintercalation process have been demonstrated. For the first time, the direct atomic-scale observation of biphasic domains (discrete occupation) in partially lithiated Fe?(MoO?)? and the one by one Na occupation (pseudo-continuous occupation) at 8d sites inmore »partially sodiated Fe?(MoO?)? are obtained during the discharge processes of Li/Fe?(MoO?)? and Na/Fe?(MoO?)? cells respectively. Our combined experimental and theoretical studies bring the new insights for the research and development of intercalation compounds as electrode materials for secondary batteries.« less

  20. Gender and snow crab occupational asthma in Newfoundland and Labrador, Canada

    SciTech Connect (OSTI)

    Howse, Dana; Gautrin, Denyse; Neis, Barbara . E-mail: bneis@mun.ca; Cartier, Andre; Horth-Susin, Lise; Jong, Michael; Swanson, Mark C.

    2006-06-15

    Fish and shellfish processing employs many thousands of people globally, with shellfish processing becoming more important in recent years. Shellfish processing is associated with multiple occupational health and safety (OHS) risks. Snow crab occupational asthma (OA) is work-related asthma associated with processing snow crab. We present a gender analysis of findings from a 3-year multifaceted study of snow crab OA in Newfoundland and Labrador, Canada. The study was carried out in four snow crab processing communities between 2001 and 2004. An anonymous survey questionnaire on knowledge, beliefs, and concerns related to processing snow crab administered to 158 workers attending community meetings at the start of the research found that women were significantly more likely than men to associate certain health problems, especially chest tightness, difficulty breathing, and cough, with crab processing (P<0.001). Worker health assessments carried out with 215 processing workers (187 current/28 former; 120 female/95 male) found that female participants were more likely to be diagnosed as almost certain/highly probable snow crab OA and allergy (P=0.001) and to be sensitized to snow crab (P=0.01) than male participants. Work histories from the health assessments were used to classify processing jobs as male or female. Allergen sampling (211 allergen samples: 115 area, 96 personal breathing zone) indicated that the plant areas where these male jobs were concentrated were associated with lower levels of aerosolized crab allergens (the agents responsible for OA to snow crab) than areas associated with female jobs. This difference was statistically significant in the two plants with poor ventilation (p<0.001 and P=0.017 for these plants). A gender analysis of work history data showed that female health assessment participants were likely to have worked longer processing snow crab than males (5 years versus 3.5 years, respectively). Cross-referencing of work history results with allergen sampling data for male and female job areas showed a gender difference in median cumulative exposures (duration of exposurexlevel of exposures) for health assessment participants. Health assessment participants with estimated higher median cumulative exposures were more likely to receive a diagnosis of almost certain/highly probable OA and allergy. Semistructured interviews with 27 health assessment participants (24 female/ 3 male) with a diagnosis of almost certain/highly probable or possible snow crab OA indicated that these workers can experience substantial quality of life impacts while working and that they seek to reduce the economic impact of their illness by remaining at their jobs as long as possible. Indications of selection bias and other study limitations point to the need for more research exploring the relationship between the gender division of labor and knowledge, beliefs, and concerns about snow crab processing, as well as gender differences in prevalence, quality of life, and socioeconomic impact.

  1. Changes in the peripheral blood transcriptome associated with occupational benzene exposure identified by cross-comparison on two microarray platforms

    E-Print Network [OSTI]

    McHale, Cliona M.

    2009-01-01

    Associated with Occupational Benzene Exposure Identified byY, Dosemeci M, and Linet M. Benzene and lymphohematopoieticamong workers exposed to benzene. Cancer Res 58: 2176-2181,

  2. Proposed Occupational Exposure Limits for Non-Carcinogenic Hanford Waste Tank Vapor Chemicals

    SciTech Connect (OSTI)

    Poet, Torka S.; Timchalk, Chuck

    2006-03-24

    A large number of volatile chemicals have been identified in the headspaces of tanks used to store mixed chemical and radioactive waste at the U.S. Department of Energy (DOE) Hanford Site, and there is concern that vapor releases from the tanks may be hazardous to workers. Contractually established occupational exposure limits (OELs) established by the Occupational Safety and Health Administration (OSHA) and American Conference of Governmental Industrial Hygienists (ACGIH) do not exist for all chemicals of interest. To address the need for worker exposure guidelines for those chemicals that lack OSHA or ACGIH OELs, a procedure for assigning Acceptable Occupational Exposure Limits (AOELs) for Hanford Site tank farm workers has been developed and applied to a selected group of 57 headspace chemicals.

  3. Occupational safety data and casualty rates for the uranium fuel cycle. [Glossaries

    SciTech Connect (OSTI)

    O'Donnell, F.R.; Hoy, H.C.

    1981-10-01

    Occupational casualty (injuries, illnesses, fatalities, and lost workdays) and production data are presented and used to calculate occupational casualty incidence rates for technologies that make up the uranium fuel cycle, including: mining, milling, conversion, and enrichment of uranium; fabrication of reactor fuel; transportation of uranium and fuel elements; generation of electric power; and transmission of electric power. Each technology is treated in a separate chapter. All data sources are referenced. All steps used to calculate normalized occupational casualty incidence rates from the data are presented. Rates given include fatalities, serious cases, and lost workdays per 100 man-years worked, per 10/sup 12/ Btu of energy output, and per other appropriate units of output.

  4. Perspective on occupational radiation exposures at a hypothetical fusion power station

    SciTech Connect (OSTI)

    Easterly, C.E.; Cannon, J.B.

    1983-01-01

    If current technology were used, several major sources of potential occupational radiation exposure at fusion power stations would be quite similar to those at current light water reactor power stations. Based upon this similarity, crude estimates of doses received from various maintenance operations at fusion power reactors are made. The dose estimates reinforce the need for concurrent development of sophisticated remote maintenance devices and low-activation materials for fusion reactors. It is concluded that minimization of occupational doses can be best achieved by developing an overall maintenance strategy that combines the best features of remote techniques and low activation materials as opposed to developing one or the other exclusively.

  5. Occupancy Sensing Adaptive Thermostat Controls A Market Review and Observations from Multiple Field Installations in University Residence Halls

    E-Print Network [OSTI]

    California at Davis, University of

    management and integrated system monitoring. #12;The occupancy control schemes are of particular interest applied to manage conditioning systems. Occupancy sensing for climate control may have the greatest impact. This is a waste of energy and money, but has historically been the only way to manage temperature and indoor air

  6. A permeation theory for single-file ion channels: Corresponding occupancy states produce MichaelisMenten behavior

    E-Print Network [OSTI]

    Nelson, Peter Hugo

    A permeation theory for single-file ion channels: Corresponding occupancy states produce Michaelis­Menten behavior Peter Hugo Nelsona) Department of Chemistry, University of Massachusetts, Amherst, Massachusetts of a Langmuir adsorption isotherm. A corresponding occupancy-states explanation is thus provided

  7. Occupational exposure assessment of magnetic fields generated by induction heating equipment--the role of spatial averaging

    E-Print Network [OSTI]

    Ljubljana, University of

    heating equipment is a source of strong and nonhomogeneous magnetic fields, which can exceed occupationalOccupational exposure assessment of magnetic fields generated by induction heating equipment for more Home Search Collections Journals About Contact us My IOPscience #12;IOP PUBLISHING PHYSICS

  8. Using occupancy to reduce energy consumption of buildings

    E-Print Network [OSTI]

    Balaji, Bharathan

    2011-01-01

    for Solar Energy Harvesting Wireless Embedded Systems. Inwww.enocean.com/en/energy- harvesting-wireless/. [11] V. L.a High-Fidelity Wireless Building Energy Auditing Network.

  9. Essential Functions/Standards for the Occupational Therapy Assistant Student The following standards pertain to particular cognitive, motor, behavioral and social skills that are

    E-Print Network [OSTI]

    Delgado, Mauricio

    Essential Functions/Standards for the Occupational Therapy Assistant Student The following standards pertain to particular cognitive, motor, behavioral and social skills that are associated Standards: A. Practice occupational therapy assistant skills and techniques under the supervision

  10. Directions to U-M Occupational Health Services (3rd floor, Med Inn Building)

    E-Print Network [OSTI]

    Kamat, Vineet R.

    at the Cardiovascular Center underground7. parking. East Hospital Drive ends at the Med Inn parking lot.8. Choose at the Cardiovascular Center underground6. parking. East Hospital Drive ends at the Med Inn parking lot.7. Choose parking lot.11. Choose a space designated for Occupational Health parking. MED INN PARKING FROM NORTH

  11. CRAD, Occupational Safety & Health- Los Alamos National Laboratory Waste Characterization, Reduction, and Repackaging Facility

    Broader source: Energy.gov [DOE]

    A section of Appendix C to DOE G 226.1-2 "Federal Line Management Oversight of Department of Energy Nuclear Facilities." Consists of Criteria Review and Approach Documents (CRADs) used for an assessment of the Occupational and Industrial Safety and Hygiene Program portion of an Operational Readiness Review at the Los Alamos National Laboratory Waste Characterization, Reduction, and Repackaging Facility.

  12. Occupant Protection and Rescue using Automotive Cyber-Physical Costin D. Untaroiu*

    E-Print Network [OSTI]

    Rajkumar, Ragunathan "Raj"

    Occupant Protection and Rescue using Automotive Cyber-Physical Systems Costin D. Untaroiu* , Jeff R. Crandall Center for Applied Biomechanics, Department of Mechanical and Aerospace Engineering, University) Background: The current trend in the automotive industry is the expanded use of embedded electronics

  13. Occupancy-Based Energy Management in Buildings: Final Report to Sponsors

    E-Print Network [OSTI]

    Cerpa, Alberto E.

    ....................................................................................................................................................................5 Task 1: Describe Energy Usage in the COB (LBNL Lead Author1 Occupancy-Based Energy Management in Buildings: Final Report to Sponsors Michael D. Sohn1 Alberto Cerpa3 , Varick Ericson3 , Ankur Kamthe3 1 Environmental Energy Technologies Division Lawrence

  14. Laser Users Eye Test Form University of Cambridge Laser Users Information for Occupational Health

    E-Print Network [OSTI]

    Cambridge, University of

    Laser Users Eye Test Form University of Cambridge Laser Users Information for Occupational Health supervisor or research group Department College Departmental Laser Safety Officer Tel: Information about the laser(s) you will be using Type of Laser Wavelength Laser Classification CW or Pulsed Power or Energy

  15. Energy Efficient Building Environment Control Strategies Using Real-time Occupancy Measurements

    E-Print Network [OSTI]

    Cerpa, Alberto E.

    Energy Efficient Building Environment Control Strategies Using Real-time Occupancy Measurements (HVAC) systems ac- count for 50% of the total energy budget in buildings [5]. Prior research has shown 10 to 15% of HVAC energy can be reduced in buildings that set ventilation rates based on maximum

  16. Water Alignment, Dipolar Interactions, and Multiple Proton Occupancy during Water-Wire Proton Transport

    E-Print Network [OSTI]

    Levine, Alex J.

    Water Alignment, Dipolar Interactions, and Multiple Proton Occupancy during Water-Wire Proton Angeles, California ABSTRACT A discrete multistate kinetic model for water-wire proton transport is constructed and analyzed using Monte Carlo simulations. In the model, each water molecule can be in one

  17. ROBERT J. BUDNITZ Occupation: Physicist in Energy/Environmental Research and Nuclear Safety

    E-Print Network [OSTI]

    Ajo-Franklin, Jonathan

    ROBERT J. BUDNITZ Occupation: Physicist in Energy/Environmental Research and Nuclear Safety Birth December 2004 to September 2007 (in Livermore): Leader, Nuclear & Risk Science Group, Energy & Environment Directorate Associate Program Leader for Nuclear Systems Safety and Security, E&E Directorate October 2002

  18. Ann. Occup. Hyg., pp. 115 The Author 2011. Published by Oxford University Press

    E-Print Network [OSTI]

    Krishnamoorthy, Kalimuthu

    ; tolerance limits INTRODUCTION The consensus standard published by the American Industrial Hygiene of the British Occupational Hygiene Society doi:10.1093/annhyg/mer014 Confidence Limits for Lognormal Percentiles.oxfordjournals.orgDownloadedfrom #12;as DL/2, and then use the methods available for uncensored samples. However, recent industrial

  19. Ann. Occup. Hyg., pp. 110 # The Author 2007. Published by Oxford University Press

    E-Print Network [OSTI]

    Krishnamoorthy, Kalimuthu

    exposure level for a job group have been well demonstrated in the industrial hygiene literature of the British Occupational Hygiene Society doi:10.1093/annhyg/mem013 Upper Limits for Exceedance Probabilities as computationally simple. Two data sets involving industrial exposure data are used to illustrate the methods

  20. Roadmap: Environmental Health and Safety -Occupational Health and Industrial Hygiene -Associate of Applied Science

    E-Print Network [OSTI]

    Khan, Javed I.

    Roadmap: Environmental Health and Safety - Occupational Health and Industrial Hygiene - Associate EVHS 21010 Industrial Hygiene II 4 PH 10002 Introduction to Global Health 3 GEOL 21062 Environmental I or PH 10001 Introduction to Public Health 1 3 EVHS 10004 Toxicology 3 EVHS 10010 Industrial

  1. An Experimental Investigation of Occupancy-Based Energy-Efficient Control of Commercial Building Indoor Climate

    E-Print Network [OSTI]

    Carloni, Luca

    An Experimental Investigation of Occupancy-Based Energy-Efficient Control of Commercial Building of the effect on indoor climate, we verify that the controller achieves the energy efficiency improvements to heating, ventilation, and air-conditioning (HVAC) systems [1]. Energy-efficient control of HVAC systems

  2. SHIFT INVARIANCE OF THE OCCUPATION TIME OF THE BROWNIAN BRIDGE PROCESS

    E-Print Network [OSTI]

    Howard, Peter

    SHIFT INVARIANCE OF THE OCCUPATION TIME OF THE BROWNIAN BRIDGE PROCESS Peter Howard and Kevin of a one-dimensional Brownian bridge process on any Lebesgue measurable set between the initial and nal states of the bridge is shown to be invariant under translation and re ection, so long as the translation

  3. SHIFT INVARIANCE OF THE OCCUPATION TIME OF THE BROWNIAN BRIDGE PROCESS

    E-Print Network [OSTI]

    Zumbrun, Kevin

    SHIFT INVARIANCE OF THE OCCUPATION TIME OF THE BROWNIAN BRIDGE PROCESS Peter Howard and Kevin time of a one­dimensional Brownian bridge process on any Lebesgue measurable set between the initial and final states of the bridge is shown to be invariant under translation and reflection, so long

  4. Accurate Real-Time Occupant Energy-Footprinting in Commercial Buildings

    E-Print Network [OSTI]

    Zhao, Feng

    consumptions [4]. As the energy crisis becomes increas- ingly urgent, we have seen a renewed interestAccurate Real-Time Occupant Energy-Footprinting in Commercial Buildings Yun Cheng , Kaifei Chen energy. While the community has been working on monitoring the building energy usage, we argue

  5. Stairwells are lit 24 hours per day regardless of occupancy. In stairwells

    E-Print Network [OSTI]

    are vacant. However, building owners and code officials have had little exposure to these emerging fixtures this technology for use in new stairwells · Inform code officials about successful applications and acceptance by code. In contrast, a new bi-level stairwell fixture with integrated occupancy sensors are easy

  6. PEDESTRIAN AVOIDANCE FOR UNMANNED GROUND VEHICLES BASED ON VELOCITY OCCUPANCY SPACE

    E-Print Network [OSTI]

    Peng, Huei

    PEDESTRIAN AVOIDANCE FOR UNMANNED GROUND VEHICLES BASED ON VELOCITY OCCUPANCY SPACE William J-time moving obstacle avoidance for Unmanned Ground Vehicles (UGVs). Pedestrian safety and comfort must be ensured by the guidance algorithm when UGVs operate near pedestrians. Studies on human interactions

  7. Student manual, Book 2: Orientation to occupational safety compliance in DOE

    SciTech Connect (OSTI)

    Colley, D.L.

    1993-10-01

    This is a student hand-book an Occupational Safety Compliance in DOE. Topics include the following: Electrical; materials handling & storage; inspection responsibilities & procedures; general environmental controls; confined space entry; lockout/tagout; office safety, ergonomics & human factors; medical & first aid, access to records; construction safety; injury/illness reporting system; and accident investigation procedures.

  8. The Smart Thermostat: Using Occupancy Sensors to Save Energy in Homes

    E-Print Network [OSTI]

    Whitehouse, Kamin

    The Smart Thermostat: Using Occupancy Sensors to Save Energy in Homes Jiakang Lu, Tamim Sookoor patterns in a home, and how to use these patterns to save energy by auto- matically turning off the home demonstrate that our approach will achieve a 28% en- ergy saving on average, at a cost of approximately $25

  9. Occupational exposures and chronic respiratory symptoms. A population-based study

    SciTech Connect (OSTI)

    Korn, R.J.; Dockery, D.W.; Speizer, F.E.; Ware, J.H.; Ferris, B.G. Jr.

    1987-08-01

    Data from a random sample of 8515 white adults residing in 6 cities in the eastern and midwestern United States were used to examine the relationships between occupational exposures to dust or to gases and fumes and chronic respiratory symptoms; 31% of the population had a history of occupational dust exposure and 30% reported exposure to gas or fumes. After adjusting for smoking habits, age, gender, and city of residence, subjects with either occupational exposure had significantly elevated prevalences of chronic cough, chronic phlegm, persistent wheeze, and breathlessness. The adjusted relative odds of chronic respiratory symptoms for subjects exposed to dust ranged from 1.32 to 1.60. Subjects with gas or fume exposure had relative odds of symptoms between 1.27 and 1.43 when compared with unexposed subjects. Occupational dust exposure was associated with a higher prevalence of chronic obstructive pulmonary disease as defined by an FEV1/FVC ratio of less than 0.6, when comparing exposed and unexposed participants (OR = 1.53, 95% Cl = 1.17-2.08). Gas or fume exposure was associated with a small, but not significant, increase in COPD prevalence. Significant trends were noted for wheeze and phlegm with increasing duration of dust exposure. Although 36% of exposed subjects reported exposure to both dust and fumes, there was no evidence of a multiplicative interaction between the effects of the individual exposures. Smoking was a significant independent predictor of symptoms, but did not appear to modify the effect of dust or fumes on symptom reporting. These data, obtained in random samples of general populations, demonstrate that chronic respiratory symptoms and disease can be independently associated with occupational exposures.

  10. Occupational exposures and chronic respiratory symptoms: a population-based study

    SciTech Connect (OSTI)

    Korn, R.J.; Dockery, D.W.; Speizer, F.E.; Ware, J.H.; Ferris, B.G.

    1987-01-01

    Data from a random sample of 8515 white adults residing in six cities in the eastern and midwestern United States were used to examine the relationships between occupational exposures to dust or to gases and fumes and chronic respiratory symptoms. 31% of the population had a history of occupational dust exposure and 30% reported exposure to gas or to fumes. After adjusting for smoking habits, age, gender, and city of residence, subjects with either occupational exposure had significantly elevated prevalence of chronic cough, chronic phlegm, persistent wheeze, and breathlessness. The adjusted relative odds of chronic respiratory symptoms for subjects exposed to dust ranged from 1.32 to 1.60. Subjects with gas or fume exposure had relative odds of symptoms between 1.27 and 1.43 when compared to unexposed subjects. Occupational dust exposure was associated with a higher prevalence of chronic obstructive pulmonary disease (COPD) as defined by an FEV1/FVC ratio of less than 0.6, when comparing exposed and unexposed participants (OR=1.53, 95% CI=1.17-2.08). Gas or fume exposure was associated with a small, but not significant, increase in COPD prevalence. Significant trends were noted for wheeze and phlegm with increasing duration of dust exposure. Although 36% of exposed subjects reported exposure to both dust and fumes, there was no evidence of a multiplicative interaction between the effects of the individual exposures. Smoking was a significant independent predictor of symptoms, but did not appear to modify the effect of dust or fumes on symptom reporting. These data, obtained in random samples of general populations, demonstrate that chronic respiratory disease can be independently associated with occupational exposures.

  11. Operating Experience Level 3, DOE Occupational Radiation Exposures for 2013

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on DeliciousMathematicsEnergyInterested Parties -DepartmentAvailableHighOffice ofProjectDepartmentOperating

  12. Order Module--NNSA OCCUPATIONAL RADIATION PROTECTION | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on DeliciousMathematicsEnergyInterested Parties -DepartmentAvailableHighOffice|Order Module--DOE OrderOrder

  13. Image-based occupancy sensor - Energy Innovation Portal

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration would likeUniverse (JournalvivoHighHusseinSOLICWfATION/MODIFICATlON OFMA!n!NEZ9,036,866 Site Map

  14. Interactive Multiscale Classification of High-Resolution Remote Sensing Images

    E-Print Network [OSTI]

    Gosselin, Philippe-Henri

    1 Interactive Multiscale Classification of High-Resolution Remote Sensing Images Jefersson Alex dos~ao Abstract The use of remote sensing images (RSIs) as a source of information in agribusiness applications in space occupation. However, the identification and recognition of crop regions in remote sensing images

  15. Zone Level Occupant-Responsive Building Energy Systems at the GSA

    SciTech Connect (OSTI)

    Robinson, Alastair

    2014-03-01

    The General Services Administration (GSA) partnered with the U.S. Department of Energy (DOE) to develop and implement building energy system retrofits, aiming to reduce energy consumption of at least two building systems by a total of 30 percent or more, as part of DOE’s Commercial Building Partnership (CBP) Program. Lawrence Berkeley National Laboratory (LBNL) provided technical expertise in support of this DOE program, working with the GSA and a team of consultants. This case study reports expected energy savings from appropriate energy efficient design and operations modifications to lighting and heating, ventilating and air conditioning (HVAC) systems at the selected study sites. These retrofits comprised installation of new lighting systems with dimming capability and occupancy-sensor control at the individual light fixture level, and utilized lighting system occupancy sensor signals to continually readjust zone-level ventilation airflow according to the number of people present, down to minimum rates when vacant.

  16. Waste collection in developing countries - Tackling occupational safety and health hazards at their source

    SciTech Connect (OSTI)

    Bleck, Daniela; Wettberg, Wieland

    2012-11-15

    Waste management procedures in developing countries are associated with occupational safety and health risks. Gastro-intestinal infections, respiratory and skin diseases as well as muscular-skeletal problems and cutting injuries are commonly found among waste workers around the globe. In order to find efficient, sustainable solutions to reduce occupational risks of waste workers, a methodological risk assessment has to be performed and counteractive measures have to be developed according to an internationally acknowledged hierarchy. From a case study in Addis Ababa, Ethiopia suggestions for the transferral of collected household waste into roadside containers are given. With construction of ramps to dump collected household waste straight into roadside containers and an adaptation of pushcarts and collection procedures, the risk is tackled at the source.

  17. Statistical Analysis of Occupational Safety Data of Voluntary Protection Program (VPP) and Non-VPP Sites

    Broader source: Energy.gov [DOE]

    The Voluntary Protection Program (VPP) was originally developed by Occupational Safety and Health Administration (OSHA) in 1982 to foster greater ownership of safety and health in the workplace. The Department of Energy (DOE) adopted VPP in 1992; currently 23 sites across the DOE complex participate in the program. As its name implies, it is a voluntary program; i.e. not required by laws or regulations.

  18. Realt-Time Building Occupancy Sensing for Supporting Demand Driven HVAC Operations 

    E-Print Network [OSTI]

    Ekwevugbe, T.; Brown, N.; Pakka, V.

    2013-01-01

    use. Previous research have proposed up to 56% HVAC related energy savings with improvements in operation and management of HVAC systems (Sun et al., 2011, Tachwali et al., 2007). Real- time building occupancy sensing is useful for efficient.... The area enjoys good natural lighting due to its large side windows, although it is shaded from the direct effect of the sun by an adjacent part of the building. It is ventilated with three glazed roof vents. The vents are controlled together by room...

  19. Mathematics This sheet has sample occupations, work settings, employers, and career development activities associated with this major. Some of these

    E-Print Network [OSTI]

    Ronquist, Fredrik

    Mathematics This sheet has sample occupations, work settings, employers, and career development Manager, Electronic Data Processing Market and Survey Researcher Mathematical Analyst Mathematical Science Administrator Mathematical Technician Psychometrician Purchasing Manager Quantitative Analyst Real Estate

  20. Design, Construction, Transportation, Operation and Post-Occupancy Analysis for the Texas A&M Solar Decathlon House 

    E-Print Network [OSTI]

    Malhotra, M.; Ramirez, E.; Im, P.; Cho, S.; Canez, J.; Haberl, J.; Schaider, N.; Fisk, P.; Feigenbaum, L.

    2008-01-01

    This paper describes the design, construction, transportation, operation and post occupancy analysis of the 2007 Texas A&M Solar Decathlon House (TAMU SD house). The TAMU SD house was developed to be a modular house that ...

  1. Perceived and reported occupational stressors and coping strategies of selected community college business faculty members in Texas 

    E-Print Network [OSTI]

    Allison, Genevieve J.

    2004-11-15

    Two primary purposes of this study were to explore and to identify the sources of occupational stressors and coping strategies perceived and reported by selected Texas community college faculty members and to generate ...

  2. Changes in the peripheral blood transcriptome associated with occupational benzene exposure identified by cross-comparison on two microarray platforms

    E-Print Network [OSTI]

    Chen, Jinsong

    Changes in the peripheral blood transcriptome associated with occupational benzene exposure Available online 20 January 2009 Keywords: Benzene exposure Gene expression Human blood Toxicogenomics Benzene is an established cause of leukemia, and possibly lymphoma, in humans, but the underlying

  3. Journal of Occupational and Environmental Hygiene, 4: 391399 ISSN: 1545-9624 print / 1545-9632 online

    E-Print Network [OSTI]

    Radwin, Robert G.

    Journal of Occupational and Environmental Hygiene, 4: 391­399 ISSN: 1545-9624 print / 1545 forces associated with industrial nutrun- ner operation but rather estimated exertions using surrogate

  4. Engineering This sheet has sample occupations, work settings, employers, and career development activities associated with this major. Some of these

    E-Print Network [OSTI]

    Ronquist, Fredrik

    Engineering This sheet has sample occupations, work settings, employers, and career development Chemical*/Biomedical Absorption Engineer Biochemical Engineer Biomedical Engineer Biotechnologist Chemical Design Engineer Chemical Engineer Chemical Technician Petroleum Engineer Polymer Engineer Civil* City

  5. Communication This sheet has sample occupations, work settings, employers, and career development activities associated with this major. Some of these

    E-Print Network [OSTI]

    Ronquist, Fredrik

    Communication This sheet has sample occupations, work settings, employers, and career development Specialist Social Media Manager Special Events Coordinator Technical Director/Manager Media and Communication of Education Communications Agencies Communications Offices Consulting Firms Corporate Settings Digital Media

  6. Code of Practice for means of escape in the case of fire at houses in multiple occupation 

    E-Print Network [OSTI]

    Anonymous

    1961-01-01

    Code of Practice for means of escape in the case of fire at houses in multiple occupation (Publication N0. 88). This is the application of section 16 of the housing act, 1961

  7. Progress on Enabling an Interactive Conversation Between Commercial Building Occupants and Their Building To Improve Comfort and Energy Efficiency: Preprint

    SciTech Connect (OSTI)

    Schott, M.; Scheib, J.; Long, N.; Fleming, K.; Benne, K.; Brackney, L.

    2012-06-01

    Many studies have reported energy savings after installing a dashboard, but dashboards provide neither individual feedback to the occupant nor the ability to report individual comfort. The Building Agent (BA) provides an interface to engage the occupant in a conversation with the building control system and the building engineer. Preliminary outcomes of the BA-enabled feedback loop are presented, and the effectiveness of the three display modes will be compared to other dashboard studies to baseline energy savings in future research.

  8. A Radiocarbon Chronology of Hunter-Gatherer Occupation from Bodega Bay, California, USA

    SciTech Connect (OSTI)

    Kennedy, M A; Russell, A D; Guilderson, T P

    2005-04-27

    The evolution of hunter-gatherer maritime adaptations in western North America has been a prominent topic of discussion among archaeologists in recent years (e.g. Arnold 1992; Erlandson and Colten 1991; Erlandson and Glassow 1997; Lightfoot 1993). Although vast coastal regions of the northeastern Pacific (for example, southern California) have been investigated in detail, our understanding of hunter-gatherer developments along the coast of northern California is limited. Previous research indicates that humans have exploited marine mammals, fish and shellfish along the northern California shoreline since the early Holocene (Schwaderer 1992). By the end of the late Holocene, some groups remained year-round on the coast subsisting primarily on marine resources (e.g. Gould 1975; Hildebrandt and Levulett 2002). However, a paucity of well-dated cultural deposits has hindered our understanding of these developments, particularly during the early and middle Holocene. The lack of a long and reliable chronological sequence has restricted our interpretations of behavioral change, including the adaptive strategies (such as foraging, mobility and settlement) used by human foragers to colonize and inhabit the coastal areas of this region. These shortcomings have also hindered comparative interpretations with other coastal and inland regions in western North America. Here we present a Holocene radiocarbon chronology of hunter-gatherer occupation based on contemporaneous samples of charcoal and Mytilus californianus (California sea mussel) shell recovered from seven archaeological sites near Bodega Bay, California. A series of 127 {sup 14}C ages reveal a chronological sequence that spans from ca. 8940-110 cal BP (1{sigma}) (7890-160 {sup 14}C yr BP = charcoal; 8934-101 {sup 14}C yr BP = shell). As part of this sequence, we report new {sup 14}C dates from the stratified cave and open-air midden deposits at Duncan's Landing (CA-SON-348/H). In addition, we present {sup 14}C ages from three middle Holocene sites located in the Bodega Dunes, and from three late Holocene sites, including Kili (CASON-299), the oldest known village site in the region. Bodega Bay (38 degrees 19 minutes N, 123 degrees 03 minutes W) is situated about 90 km north of San Francisco Bay, California (Figure 1). The Pacific, in conjunction with prominent geomorphological features, has given rise to a series of coastal habitats (e.g. semi-protected and protected shorelines) around Bodega Bay that are rather unique for the unprotected, surf swept rocky shores of northern California. This stretch of coastline also lies within a zone of particularly strong seasonal upwelling between Point Reyes Peninsula and Cape Mendocino; a region characterized by high Ekman transport (Huyer 1983), and high coastal concentrations of the nutrients silica and phosphate (van Geen and Husby 1996). The interaction between land and sea results in a productive marine ecosystem that has attracted hunter-gatherers for much of the Holocene.

  9. Networks Inferred from Biochemical Data Reveal Profound Differences in Toll-like Receptor and Inflammatory Signaling between Normal and Transformed Hepatocytes

    E-Print Network [OSTI]

    Alexopoulos, Leonidas G.

    Systematic study of cell signaling networks increasingly involves high throughput proteomics, transcriptional profiling, and automated literature mining with the aim of assembling large-scale interaction networks. In ...

  10. Bayesian based design of real-time sensor systems for high-risk indoor contaminants

    E-Print Network [OSTI]

    Sreedharan, Priya

    2007-01-01

    the influence of occupant behavior (Klepeis and Nazaroff,the influence of occupant behavior on room airflow patternslibrary based on occupant behavior and weather conditions.

  11. Mechanical-biological waste treatment and the associated occupational hygiene in Finland

    SciTech Connect (OSTI)

    Tolvanen, Outi K. . E-mail: outolvan@bytl.jyu.fi; Haenninen, Kari I.

    2006-07-01

    A special feature of waste management in Finland has been the emphasis on the source separation of kitchen biowaste (catering waste); more than two-thirds of the Finnish population participates in this separation. Source-separated biowaste is usually treated by composting. The biowaste of about 5% of the population is handled by mechanical-biological treatment. A waste treatment plant at Mustasaari is the only plant in Finland using digestion for kitchen biowaste. For the protection of their employees, the plant owners commissioned a study on environmental factors and occupational hygiene in the plant area. During 1998-2000 the concentrations of dust, microbes and endotoxins and noise levels were investigated to identify possible problems at the plant. Three different work areas were investigated: the pre-processing and crushing hall, the bioreactor hall and the drying hall. Employees were asked about work-related health problems. Some problems with occupational hygiene were identified: concentrations of microbes and endotoxins may increase to levels harmful to health during waste crushing and in the bioreactor hall. Because employees complained of symptoms such as dry cough and rash or itching appearing once or twice a month, it is advisable to use respirator masks (class P3) during dusty working phases. The noise level in the drying hall exceeded the Finnish threshold value of 85 dBA. Qualitatively harmful factors for the health of employees are similar in all closed waste treatment plants in Finland. Quantitatively, however, the situation at the Mustasaari treatment plant is better than at some Finnish dry waste treatment plants. Therefore is reasonable to conclude that mechanical sorting, which produces a dry waste fraction for combustion and a biowaste fraction for anaerobic treatment, is in terms of occupational hygiene better for employees than combined aerobic treatment and dry waste treatment.

  12. Rev 3.0For more information about Matrix Fitness: matrixfitness.com | Toll-Free 866.693.4863 DRIVE SYSTEM

    E-Print Network [OSTI]

    Thomas, David D.

    -compatible pedals to provide maximum comfort. Eye-catching Aesthetics High-gloss platinum finish with carbon fiber effect plastics and rust-resistant powder coating. COMFORTABLE 4-way, micro-adjustable handlebar bracket and crank assembly featuring 4 SKF precision bearings and forged high-carbon cranks for increased

  13. Occupation Codes

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankADVANCED MANUFACTURINGEnergy Bills and ReduceNovemberDOE's Priorities |Weatherization Funding andFunding

  14. Distribution of occupation numbers in finite Fermi systems and role of interaction in chaos and thermalization

    SciTech Connect (OSTI)

    Flambaum, V.V.; Izrailev, F.M. [School of Physics, University of New South Wales, Sydney 2052 (Australia)] [School of Physics, University of New South Wales, Sydney 2052 (Australia)

    1997-01-01

    A method is developed for calculation of single-particle occupation numbers in finite Fermi systems of interacting particles. It is more accurate than the canonical distribution method and gives the Fermi-Dirac distribution in the limit of large number of particles. It is shown that statistical effects of the interaction are absorbed by an increase of the effective temperature. Criteria for quantum chaos and statistical equilibrium are considered. All results are confirmed by numerical experiments in the two-body random interaction model. {copyright} {ital 1997} {ital The American Physical Society}

  15. The Post-occupancy Performance of Green Office Buildings: Evidence for the Fiekd 

    E-Print Network [OSTI]

    Newsham, G.

    2013-01-01

    ? Fine-tuning of certification systems to ensure better performance ? A research consortium http://archive.nrc-cnrc.gc.ca/eng/projects/irc/post-occupancy.html Partners PERD Field study stud G ti l ffi b ildi (N 24)? reen vs. conven ona o ce u ngs... = ? Matched pairs ? Across Canada and northern US public and private sector , ? Size: 1300 to 38500 m2 ? Age: 1956 to 2009 ? Green: mostly LEED at some level http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/ctrl?action=rtdoc&an=20857897&article=0&fd...

  16. A Formaldehyde Exposure Assessment Tool for Occupants of FEMA Temporary Housing Units

    SciTech Connect (OSTI)

    Parthasarathy, Srinandini; Spears, Michael; Maddalena, Randy L.; Russell, Marion L; Apte, Michael G.

    2010-10-01

    The report outlines the methodology used to develop a web-based tool to assess the formaldehyde exposure of the occupants of Federal Emergency Management Administration (FEMA) temporary housing units (THUs) after Hurricanes Katrina and Rita in 2005. Linear regression models were built using available data to retrospectively estimate the indoor temperature and relative humidity, formaldehyde emission factors and concentration, and hence the formaldehyde exposures. The interactive web-tool allows the user to define the inputs to the model to evaluate formaldehyde exposures for different scenarios.

  17. 10 C.F.R. PART 835-OCCUPATIONAL RADIATION PROTECTION, Subpart A - General Provisions

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i n c i p a l De p u t y A s s i s t a n t S eOF 11 DOCUMENT5-OCCUPATIONAL

  18. Achieving Energy Savings with Highly-Controlled Lighting in an Open-Plan Office

    SciTech Connect (OSTI)

    Rubinstein, Francis; Enscoe, Abby

    2010-04-19

    An installation in a Federal building tested the effectiveness of a highly-controlled, workstation-specific lighting retrofit. The study took place in an open-office area with 86 cubicles and low levels of daylight. Each cubicle was illuminated by a direct/indirectpendant luminaire with three 32 watt lamps, two dimmable DALI ballasts, and an occupancy sensor. A centralized control system programmed all three lamps to turn on and off according to occupancy on a workstation-by-workstation basis. Field measurements taken over the course of several monthsdemonstrated 40% lighting energy savings compared to a baseline without advanced controls that conforms to GSA's current retrofit standard. A photometric analysis found that the installation provided higher desktop light levels than the baseline, while an occupant survey found that occupants in general preferred the lighting system to thebaseline.Simple payback is fairly high; projects that can achieve lower installation costs and/or higher energy savings and those in which greenhouse gas reduction and occupant satisfaction are significant priorities provide the ideal setting for workstation-specific lighting retrofits.

  19. Occupational radiation dose assessment for a non site specific spent fuel storage facility

    SciTech Connect (OSTI)

    Hadley, J. [Duke Engineering and Services, Inc., Charlotte, NC (United States); Eble, R.G. Jr. [Duke Engineering and Services, Inc., Vienna, VA (United States)

    1997-12-01

    To expedite the licensing process of the non site specific Centralized Interim Storage Facility (CISF) the Department of Energy has completed a phase I CISF Topical Safety Analysis Report (TSAR). The TSAR will be used in licensing the phase I CISF if a site is designated. An occupational radiation does assessment of the facility operations is performed as part of the phase I CISF design. The first phase of the CISF has the capability to receive, transfer, and store SNF in dual-purpose cask/canister systems (DPC`s). Currently there are five vendor technologies under consideration. The preliminary dose assessment is based on estimated occupational exposures using traditional power plant ISFSI and transport cask handling processes. The second step in the process is to recommend ALARA techniques to reduce potential exposures. A final dose assessment is completed implementing the ALARA techniques and a review is performed to ensure that the design is in compliance with regulatory criteria. The dose assessment and ALARA evaluation are determined using the following input information: Dose estimates from vendor SAR`s; ISFSI experience with similar systems; Traditional methods of operations; Expected CISF cask receipt rates; and feasible ALARA techniques. 5 refs., 1 tab.

  20. Occupational dose reduction at Department of Energy contractor facilities: Study of ALARA programs. Status 1990

    SciTech Connect (OSTI)

    Dionne, B.J.; Meinhold, C.B.; Khan, T.A.; Baum, J.W.

    1992-08-01

    This report provides the US Department of Energy (DOE) and its contractors with information that will be useful for reducing occupational radiation doses at DOE`s nuclear facilities. In 1989 and 1990, health physicists from the Brookhaven National Laboratory`s (BNL) ALARA Center visited twelve DOE contractor facilities with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). The health physicists interviewed radiological safety staff, engineers, and training personnel who were responsible for dose control. The status of ALARA practices at the major contractor facilities was compared with the requirements and recommendation in DOE Order 5480.11 ``Radiation Protection for Occupational Workers`` and PNL-6577 ``Health Physics Manual of Good Practices for Reducing Radiation Exposure to Levels that are as Low as Reasonably Achievable.`` The information and data collected are described and examples of successful practices are presented. The findings on the status of the DOE Contractor ALARA Programs are summarized and evaluated. In addition, the supplement to this report contains examples of good-practice documents associated with implementing the major elements of a formally documented ALARA program for a major DOE contractor facility.

  1. Occupational radiation dose assessment for the DOE spent-fuel storage facility

    SciTech Connect (OSTI)

    Hadley, J. [Duke Engineering and Services, Charlotte, NC (United States); Eble, R.G. Jr. [Duke Engineering & Services, Vienna, VA (United States)

    1997-12-01

    To expedite the licensing process of the centralized interim storage facility (CISF), the U.S. Department of Energy has completed a CISF topical safety analysis report (TSAR). The TSAR will be used in licensing the CISF when a site is designated. An occupational radiation dose assessment of the facility operations is performed as part of the CISF design. The first phase of the CISF has the capability to receive, transfer, and store spent nuclear fuel (SNF) in dual-purpose casks. Currently, there are five vendor technologies under consideration. The preliminary dose assessment is based on estimated occupational exposures using traditional power plant independent spent-fuel storage installation (ISFSI) and transport cask-handling processes. The second step in the process is to recommend as-low-as-reasonably-achievable (ALARA) techniques to reduce potential exposures. A final dose assessment is completed implementing the ALARA techniques, and a review is performed to ensure that the design is in compliance with regulatory criteria. The dose assessment and ALARA evaluation are determined using the following input information: dose estimates from vendor safety analysis reports, ISFSI experience with similar systems, traditional methods of operations, expected CISF cask receipt rates, and feasible ALARA techniques.

  2. Review of Literature on Terminal Box Control, Occupancy Sensing Technology and Multi-zone Demand Control Ventilation (DCV)

    SciTech Connect (OSTI)

    Liu, Guopeng; Dasu, Aravind R.; Zhang, Jian

    2012-03-01

    This report presents an overall review of the standard requirement, the terminal box control, occupancy sensing technology and DCV. There is system-specific guidance for single-zone systems, but DCV application guidance for multi-zone variable air volume (VAV) systems is not available. No real-world implementation case studies have been found using the CO2-based DCV. The review results also show that the constant minimum air flow set point causes excessive fan power consumption and potential simultaneous heating and cooling. Occupancy-based control (OBC) is needed for the terminal box in order to achieve deep energy savings. Key to OBC is a technology for sensing the actual occupancy of the zone served in real time. Several technologies show promise, but none currently fully meets the need with adequate accuracy and sufficiently low cost.

  3. Radiation-Generating Devices Guide for Use with Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1999-04-15

    For use with Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection. This Guide provides an acceptable methodology for establishing and operating a sealed radioactive source accountability and control program that will comply with U.S. Department of Energy (DOE) requirements specified in Title 10 of the Code of Federal Regulations (CFR), Part 835, Occupational Radiation Protection (DOE 1998a), hereinafter referred to as 10 CFR 835. In particular, this Guide provides guidance for achieving compliance with subpart M of 10 CFR 835. Canceled by DOE G 441.1-1B.

  4. Foundations on Sand: An Analysis of the First U.S. Occupation of Haiti, 1915-1934

    E-Print Network [OSTI]

    Bunce, Peter L.

    2003-01-01

    in the Population . 48 Culture .. 49 Table 2: Haiti's Rulers Since Independence . 51 Part HI: The Never-ending Story... 54 Annexes 57 Annex A: The US Marine Corps'Military Campaigns in the First United States Occupation of Haiti 57 Appendix 1; First... Provisional Brigade of Marines 66 Appendix 2: Ships of the 1915 Haitian Campaign 74 Appendix 3: The Gendarmerie (Garde) d'Haïti, 1916-1934 75 Annex B: The Fiscal Case for Occupation 81 Appendix 1: Public Debt of Haiti, 1919 vs. 1922 93 vii Appendix 2...

  5. Art / Arts Management This sheet has sample occupations, work settings, employers, and career development activities associated with this major. Some of these

    E-Print Network [OSTI]

    Ronquist, Fredrik

    Art / Arts Management This sheet has sample occupations, work settings, employers, and career Occupations Airbrush Artist Animator/Multimedia Artist Architect Archivist/Curator Art Appraiser Art Center Director Art Conservator Art Director (Motion Picture, Radio, TV) Art Educator Art Therapist Art Agent

  6. Occupant-generated CO/sub 2/ as an indicator of ventilation rate

    SciTech Connect (OSTI)

    Turiel, I.; Rudy, J.

    1980-04-01

    Ventilation rates in buildings are generally determined by means of tracer-gas techniques that permit calculation of the number of air changes per hour occurring in a given area, or, alternatively, by measuring the actual air flow in the ventilation ducts. There are difficulties associated with both of these methods. In this study in a San Francisco office building, we used occupant-generated CO/sub 2/ as an indicator of the actual ventilation rate. Two techniques were employed, a decay method and an integral method and, in both cases, measurements were conducted simultaneously at several locations. The decay method compared favorably with the conventional measurement methods in both the all-outside-air and recirculation modes, whereas the integral method showed a considerable deviation from the other methods in the recirculation mode. Both techniques show promise of being suitable methods for measuring ventilation rate in commercial or institutional buildings.

  7. Evaluation of S-101 courses Orientation to Occupational Safety Compliance in DOE''

    SciTech Connect (OSTI)

    Wright, T S

    1992-02-01

    This section summarizes trainee evaluations for the Safety Training Section course, Supervisors' Orientation to Occupational Safety in DOE,'' (S-101) which was conducted August 5 to 8, 1991 at Hanford, in Richland, Washington. This report summarizes the quantitative course evaluations that trainees provided upon completion of the course. Appendix A provides a transcript of the trainees' written comments. Numeric course ratings were generally positive and show that the course material and instruction were very effective. Written comments supported the positive numeric ratings. The course content and knowledge gained by the trainees exceeded most of the students' expectations of the course. Results from the final examination showed that students gained significant knowledge from the course.

  8. Improving the Success Rate of Delivering Annual Occupational Dosimetry Reports to Persons Issued Temporary External Dosimeters

    SciTech Connect (OSTI)

    Mallett, Michael Wesley [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-09-09

    Workers who are not routinely monitored for occupational radiation exposure at LANL may be issued temporary dosimeters in the field. Per 10CFR835 and DOE O 231.1A, the Laboratory's radiation protection program is responsible for reporting these results to the worker at the end of the year. To do so, the identity of the worker and their mailing address must be recorded by the delegated person at the time the dosimeter is issued. Historically, this data has not been consistently captured. A new online application was developed to record the issue of temporary dosimeters. The process flow of the application was structured such that: 1) the worker must be uniquely identified in the Lab's HR database, and 2) the mailing address of record is verified live time via a commercial web service, for the transaction to be completed. A COPQ savings (Type B1) of $96K/year is demonstrated for the new application.

  9. Comparing the College of Charleston to Other Institutions: Overview of Employees by Occupational Category South Carolina Institutions

    E-Print Network [OSTI]

    Kunkle, Tom

    of Employees by Occupational Category South Carolina Institutions Aspirational Peers Institutional Research Citadel Military College of South Carolina 715 268 12 88 9 33 43 9 59 122 54 18 Clemson,582 594 72 128 49 62 154 45 208 179 49 40 University of South CarolinaColumbia 7,866 2

  10. Journal of Occupational and Environmental Hygiene, 3: 642650 ISSN: 1545-9624 print / 1545-9632 online

    E-Print Network [OSTI]

    Krishnamoorthy, Kalimuthu

    equivalent to those based on the Land's method. We want to draw the attention of the industrial hygieneJournal of Occupational and Environmental Hygiene, 3: 642­650 ISSN: 1545-9624 print / 1545 distributions. Several examples involving industrial exposure data are used to illustrate the methods. An added

  11. Journal of Occupational and Environmental Hygiene, 3: 7279 ISSN: 1545-9624 print / 1545-9632 online

    E-Print Network [OSTI]

    Radwin, Robert G.

    Journal of Occupational and Environmental Hygiene, 3: 72­79 ISSN: 1545-9624 print / 1545,4 and Thomas M. Best2,3 1 Department of Industrial Engineering, University of Wisconsin, Madison, Wisconsin 2-mail: radwin@ bme.wisc.edu. E ccentric exertions (muscle lengthening contrac- tions) can occur in industrial

  12. Enabling Building Energy Auditing Using Adapted Occupancy Ankur Kamthe, Varick Erickson, Miguel A. Carreira-Perpi~nan and Alberto Cerpa

    E-Print Network [OSTI]

    Cerpa, Alberto E.

    energy consumption has become important due to stricter energy regulations, increasing en- ergy costsEnabling Building Energy Auditing Using Adapted Occupancy Models Ankur Kamthe, Varick Erickson of California, Merced {akamthe,verickson,mcarreira-perpinan,acerpa}@ucmerced.edu Abstract Understanding building

  13. Enabling Building Energy Auditing Using Adapted Occupancy Ankur Kamthe, Varick Erickson, Miguel A. Carreira-Perpi~nan and Alberto Cerpa

    E-Print Network [OSTI]

    Cerpa, Alberto E.

    Enabling Building Energy Auditing Using Adapted Occupancy Models Ankur Kamthe, Varick Erickson and also as buildings have long term impact on energy consumption. In order to recommend retrofits, it is important to have accurate estimates for building energy consumption which is affected significantly

  14. Preferential Eu Site Occupation and Its Consequences in the Ternary Luminescent HalidesAB2I5:Eu2+(A=Li–Cs;B=Sr, Ba)

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Fang, C.? M.; Biswas, Koushik

    2015-07-22

    Several rare-earth-doped, heavy-metal halides have recently been identified as potential next-generation luminescent materials with high efficiency at low cost. AB2I5:Eu2+ (A=Li–Cs; B=Sr, Ba) is one such family of halides. Its members, such as CsBa2I5:Eu2+ and KSr2I5:Eu2+, are currently being investigated as high-performance scintillators with improved sensitivity, light yield, and energy resolution less than 3% at 662 keV. Within the AB2I5 family, our first-principles-based calculations reveal two remarkably different trends in Eu site occupation. The substitutional Eu ions occupy both eightfold-coordinated B1(VIII) and the sevenfold-coordinated B2(VII) sites in the Sr-containing compounds. However, in the Ba-containing crystals, Eu ions strongly prefer themore »B2(VII)sites. This random versus preferential distribution of Eu affects their electronic properties. The calculations also suggest that in the Ba-containing compounds one can expect the formation of Eu-rich domains. These results provide atomistic insight into recent experimental observations about the concentration and temperature effects in Eu-doped CsBa2I5. We discuss the implications of our results with respect to luminescent properties and applications. We also hypothesize Sr, Ba-mixed quaternary iodides ABaVIIISrVIII5:Eu as scintillators having enhanced homogeneity and electronic properties.« less

  15. Occupational health and environment research 1983: Health, Safety, and Environment Division. Progress report

    SciTech Connect (OSTI)

    Voelz, G.L. (comp.)

    1985-05-01

    The primary responsibility of the Health, Safety, and Environment (HSE) Division at the Los Alamos National Laboratory is to provide comprehensive occupational health and safety programs, waste processing, and environmental protection. These activities are designed to protect the workers, the public, and the environment. Evaluation of respiratory protective equipment included the XM-30 and M17A1 military masks, use of MAG-1 spectacles in respirators, and eight self-contained units. The latter units were used in an evaluation of test procedures used for Bureau of Mines approval of breathing apparatuses. Analyses of air samples from field studies of a modified in situ oil shale retorting facility were performed for total cyclohexane extractables and selected polynuclear aromatic hydrocarbons. Aerosols generation and characterization of effluents from oil shale processing were continued as part of an inhalation toxicology study. Additional data on plutonium excretion in urine are presented and point up problems in using the Langham equation to predict plutonium deposition in the body from long-term excretion data. Environmental surveillance at Los Alamos during 1983 showed the highest estimated radiation dose from Laboratory operations to be about 26% of the natural background radiation dose. Several studies on radionuclides and their transport in the Los Alamos environment are described. The chemical quality of surface and ground water near the geothermal hot dry rock facility is described. Short- and long-term consequences to man from releases of radionuclides into the environment can be simulated by the BIOTRAN computer model, which is discussed brirfly.

  16. Thermally-assisted-occupation density functional theory with generalized-gradient approximations

    SciTech Connect (OSTI)

    Chai, Jeng-Da

    2014-05-14

    We extend the recently proposed thermally-assisted-occupation density functional theory (TAO-DFT) [J.-D. Chai, J. Chem. Phys. 136, 154104 (2012)] to generalized-gradient approximation (GGA) exchange-correlation density functionals. Relative to our previous TAO-LDA (i.e., the local density approximation to TAO-DFT), the resulting TAO-GGAs are significantly superior for a wide range of applications, such as thermochemistry, kinetics, and reaction energies. For noncovalent interactions, TAO-GGAs with empirical dispersion corrections are shown to yield excellent performance. Due to their computational efficiency for systems with strong static correlation effects, TAO-LDA and TAO-GGAs are applied to study the electronic properties (e.g., the singlet-triplet energy gaps, vertical ionization potentials, vertical electron affinities, fundamental gaps, and symmetrized von Neumann entropy) of acenes with different number of linearly fused benzene rings (up to 100), which is very challenging for conventional electronic structure methods. The ground states of acenes are shown to be singlets for all the chain lengths studied here. With the increase of acene length, the singlet-triplet energy gaps, vertical ionization potentials, and fundamental gaps decrease monotonically, while the vertical electron affinities and symmetrized von Neumann entropy (i.e., a measure of polyradical character) increase monotonically.

  17. Radiation Safety Training Guide for Use with Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1999-03-17

    This Guide provides an acceptable methodology for establishing and operating a radiation safety training program that will comply with U.S. Department of Energy (DOE) requirements specified in Title 10 of the Code of Federal Regulations (CFR), Part 835, Occupational Radiation Protection (DOE 1998a), hereinafter referred to as 10 CFR 835. In particular, this Guide provides guidance for achieving compliance with subpart J of 10 CFR 835. Canceled by DOE G 441.1-1B.

  18. Interplay between promoter occupancy and chromatin remodeling requirements in transactivation of the S.cerevisiae PHO5 gene 

    E-Print Network [OSTI]

    Dhasarathy, Archana

    2006-04-12

    ) __________________________ _________________________ Geoffrey Kapler Gregory D. Reinhart (Chair of Genetics Faculty) (Head of Department) December 2004 Major Subject: Genetics iii ABSTRACT Interplay Between Promoter Occupancy and Chromatin Remodeling Requirements in Transactivation... in particular for always being there for me through thick and thin! I?d like to express my gratitude to Angela Domitrovich, Libin Wang, Toni-Ann Mistretta and Lisa Forrester for their endless advice and support. I owe a debt of appreciation to Kelly...

  19. Development and reliability testing of a self-report instrument to measure the office layout as a correlate of occupational sitting

    E-Print Network [OSTI]

    Duncan, Mitch J.; Rashid, Mahbub; Vandelanotte, Corneel; Cutumisu, Nicoleta; Plotnikoff, Ronald C.

    2013-02-04

    .001) differences, in theoretically expected directions, were observed for all scales between office types, except overall connectivity. Significant associations were observed between all scales and occupational sitting behaviour (p???0.05). Conclusion: All...

  20. DOE 2011 Occupational Radiation Exposure report, _Prepared for the U.S. Department of Energy, Office of Health, Safety and Security. December 2012

    SciTech Connect (OSTI)

    Derek Hagemeyer, Yolanda McCormick

    2012-12-12

    This report discusses radiation protection and dose reporting requirements, presents the 2011 occupational radiation dose data along with trends over the past 5 years, and provides instructions to submit successful as low as reasonably achievable (ALARA) projects.

  1. Management Information Systems (MIS) This sheet has sample occupations, work settings, employers, and career development activities associated with this major. Some of these

    E-Print Network [OSTI]

    Ronquist, Fredrik

    Management Information Systems (MIS) This sheet has sample occupations, work settings, employers Security Specialist Computer Software Engineer Computer Support Specialist Computer and Information Systems/Officer Information Systems Analyst Information Technology Specialist Internet Recruiter Knowledge Manager Logistics

  2. Beyond Occupational Differences: The Importance of Cross-cutting Demographics and Dyadic Toolkits for Collaboration in a U.S. Hospital

    E-Print Network [OSTI]

    DiBenigno, Julia Marie

    We use data from a 12-month ethnographic study of two medical-surgical units in a U.S. hospital to examine how members from different occupations can collaborate with one another in their daily work despite differences in ...

  3. Occupant-in-Place Energy Efficiency Retrofit in a Group Home for 30% Energy Savings in Climate Zone 4

    SciTech Connect (OSTI)

    Moore, Mike

    2013-08-01

    Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes – such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the study’s results will be used to identify cost-effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

  4. Occupant-in-Place Energy Efficiency Retrofit in a Group Home for 30% Energy Savings in Climate Zone 4

    SciTech Connect (OSTI)

    Moore, M.

    2013-08-01

    Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes - such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost-effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the study's results will be used to identify cost effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

  5. Determinants of residential electricity consumption: Using smart meter data to examine the effect of climate, building characteristics, appliance stock, and occupants' behavior

    SciTech Connect (OSTI)

    Kavousian, A; Rajagopal, R; Fischer, M

    2013-06-15

    We propose a method to examine structural and behavioral determinants of residential electricity consumption, by developing separate models for daily maximum (peak) and minimum (idle) consumption. We apply our method on a data set of 1628 households' electricity consumption. The results show that weather, location and floor area are among the most important determinants of residential electricity consumption. In addition to these variables, number of refrigerators and entertainment devices (e.g., VCRs) are among the most important determinants of daily minimum consumption, while number of occupants and high-consumption appliances such as electric water heaters are the most significant determinants of daily maximum consumption. Installing double-pane windows and energy-efficient lights helped to reduce consumption, as did the energy-conscious use of electric heater. Acknowledging climate change as a motivation to save energy showed correlation with lower electricity consumption. Households with individuals over 55 or between 19 and 35 years old recorded lower electricity consumption, while pet owners showed higher consumption. Contrary to some previous studies, we observed no significant correlation between electricity consumption and income level, home ownership, or building age. Some otherwise energy-efficient features such as energy-efficient appliances, programmable thermostats, and insulation were correlated with slight increase in electricity consumption. (C) 2013 Elsevier Ltd. All rights reserved.

  6. Measured Performance and Analysis of Ground Source Heat Pumps for Space Conditioning and for Water Heating in a Low-Energy Test House Operated under Simulated Occupancy Conditions

    SciTech Connect (OSTI)

    Ally, Moonis Raza [ORNL] [ORNL; Munk, Jeffrey D [ORNL] [ORNL; Baxter, Van D [ORNL] [ORNL; Gehl, Anthony C [ORNL] [ORNL

    2012-01-01

    In this paper we present measured performance and efficiency metrics of Ground Source Heat Pumps (GSHPs) for space conditioning and for water heating connected to a horizontal ground heat exchanger (GHX) loop. The units were installed in a 345m2 (3700ft2) high-efficiency test house built with structural insulated panels (SIPs), operated under simulated occupancy conditions, and located in Oak Ridge, Tennessee (USA) in US Climate Zone 4 . The paper describes distinctive features of the building envelope, ground loop, and equipment, and provides detailed monthly performance of the GSHP system. Space conditioning needs of the house were completely satisfied by a nominal 2-ton (7.0 kW) water-to-air GSHP (WA-GSHP) unit with almost no auxiliary heat usage. Recommendations for further improvement through engineering design changes are identified. The comprehensive set of data and analyses demonstrate the feasibility and practicality of GSHPs in residential applications and their potential to help achieve source energy and greenhouse gas emission reduction targets set under the IECC 2012 Standard.

  7. Controlling intake of uranium in the workplace: Applications of biokinetic modeling and occupational monitoring data

    SciTech Connect (OSTI)

    Leggett, Richard Wayne; Eckerman, Keith F; McGinn, Wilson; Meck, Dr. Robert A.

    2012-01-01

    This report provides methods for interpreting and applying occupational uranium monitoring data. The methods are based on current international radiation protection guidance, current information on the chemical toxicity of uranium, and best available biokinetic models for uranium. Emphasis is on air monitoring data and three types of bioassay data: the concentration of uranium in urine; the concentration of uranium in feces; and the externally measured content of uranium in the chest. Primary Reference guidance levels for prevention of chemical effects and limitation of radiation effects are selected based on a review of current scientific data and regulatory principles for setting standards. Generic investigation levels and immediate action levels are then defined in terms of these primary guidance levels. The generic investigation and immediate actions levels are stated in terms of radiation dose and concentration of uranium in the kidneys. These are not directly measurable quantities, but models can be used to relate the generic levels to the concentration of uranium in air, urine, or feces, or the total uranium activity in the chest. Default investigation and immediate action levels for uranium in air, urine, feces, and chest are recommended for situations in which there is little information on the form of uranium taken into the body. Methods are prescribed also for deriving case-specific investigation and immediate action levels for uranium in air, urine, feces, and chest when there is sufficient information on the form of uranium to narrow the range of predictions of accumulation of uranium in the main target organs for uranium: kidneys for chemical effects and lungs for radiological effects. In addition, methods for using the information herein for alternative guidance levels, different from the ones selected for this report, are described.

  8. Potholes or Tolls? Perspectives on Transportation Finance

    E-Print Network [OSTI]

    Bustamante, Fabián E.

    passenger car fuel efficiency http://www.rita.dot.gov/bts/sites/rita.dot.gov.bts/files/publications/national_transportation_statistics/html/table Soybean Exports 44.5x106 metric tons Panama Canalhttp://nass Highway trust fund 1956 87% from motor fuels, rest from excise taxes; Waterways, Airport & Airways

  9. INL High Performance Building Strategy

    SciTech Connect (OSTI)

    Jennifer D. Morton

    2010-02-01

    High performance buildings, also known as sustainable buildings and green buildings, are resource efficient structures that minimize the impact on the environment by using less energy and water, reduce solid waste and pollutants, and limit the depletion of natural resources while also providing a thermally and visually comfortable working environment that increases productivity for building occupants. As Idaho National Laboratory (INL) becomes the nation’s premier nuclear energy research laboratory, the physical infrastructure will be established to help accomplish this mission. This infrastructure, particularly the buildings, should incorporate high performance sustainable design features in order to be environmentally responsible and reflect an image of progressiveness and innovation to the public and prospective employees. Additionally, INL is a large consumer of energy that contributes to both carbon emissions and resource inefficiency. In the current climate of rising energy prices and political pressure for carbon reduction, this guide will help new construction project teams to design facilities that are sustainable and reduce energy costs, thereby reducing carbon emissions. With these concerns in mind, the recommendations described in the INL High Performance Building Strategy (previously called the INL Green Building Strategy) are intended to form the INL foundation for high performance building standards. This revised strategy incorporates the latest federal and DOE orders (Executive Order [EO] 13514, “Federal Leadership in Environmental, Energy, and Economic Performance” [2009], EO 13423, “Strengthening Federal Environmental, Energy, and Transportation Management” [2007], and DOE Order 430.2B, “Departmental Energy, Renewable Energy, and Transportation Management” [2008]), the latest guidelines, trends, and observations in high performance building construction, and the latest changes to the Leadership in Energy and Environmental Design (LEED®) Green Building Rating System (LEED 2009). The document employs a two-level approach for high performance building at INL. The first level identifies the requirements of the Guiding Principles for Sustainable New Construction and Major Renovations, and the second level recommends which credits should be met when LEED Gold certification is required.

  10. Spatial and temporal variations in indoor environmental conditions, human occupancy, and operational characteristics in a new hospital building

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Ramos, Tiffanie; Dedesko, Sandra; Siegel, Jeffrey A.; Gilbert, Jack A.; Stephens, Brent

    2015-03-02

    The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogatemore »measures for human occupancy and activity in the patient rooms using both indoor air CO? concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ~8×10? data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.« less

  11. Spatial and temporal variations in indoor environmental conditions, human occupancy, and operational characteristics in a new hospital building

    SciTech Connect (OSTI)

    Ramos, Tiffanie; Dedesko, Sandra; Siegel, Jeffrey A.; Gilbert, Jack A.; Stephens, Brent

    2015-03-02

    The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogate measures for human occupancy and activity in the patient rooms using both indoor air CO? concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ~8×10? data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.

  12. Re-Assessing Green Building Performance: A Post Occupancy Evaluation of 22 GSA Buildings

    SciTech Connect (OSTI)

    Fowler, Kimberly M.; Rauch, Emily M.; Henderson, Jordan W.; Kora, Angela R.

    2010-06-01

    2nd report on the performance of GSA's sustainably designed buildings. The purpose of this study was to provide an overview of measured whole building performance as it compares to GSA and industry baselines. The PNNL research team found the data analysis illuminated strengths and weaknesses of individual buildings as well as the portfolio of buildings. This section includes summary data, observations that cross multiple performance metrics, discussion of lessons learned from this research, and opportunities for future research. The summary of annual data for each of the performance metrics is provided in Table 25. The data represent 1 year of measurements and are not associated with any specific design features or strategies. Where available, multiple years of data were examined and there were minimal significant differences between the years. Individually focused post occupancy evaluation (POEs) would allow for more detailed analysis of the buildings. Examining building performance over multiple years could potentially offer a useful diagnostic tool for identifying building operations that are in need of operational changes. Investigating what the connection is between the building performance and the design intent would offer potential design guidance and possible insight into building operation strategies. The 'aggregate operating cost' metric used in this study represents the costs that were available for developing a comparative industry baseline for office buildings. The costs include water utilities, energy utilities, general maintenance, grounds maintenance, waste and recycling, and janitorial costs. Three of the buildings that cost more than the baseline in Figure 45 have higher maintenance costs than the baseline, and one has higher energy costs. Given the volume of data collected and analyzed for this study, the inevitable request is for a simple answer with respect to sustainably designed building performance. As previously stated, compiling the individual building values into single metrics is not statistically valid given the small number of buildings, but it has been done to provide a cursory view of this portfolio of sustainably designed buildings. For all metrics except recycling cost per rentable square foot and CBE survey response rate, the averaged building performance was better than the baseline for the GSA buildings in this study.

  13. Iron site occupancies in magnetite-ulvospinel solid solution: A new approach using XMCD

    SciTech Connect (OSTI)

    Pearce, C. I.; Henderson, C. M. B.; Telling, N. D.; Pattrick, R. A.D.; Vaughan, D. J.; Charnock, J. M.; Arenholz, E.; Tuna, F.; Coker, V.S.; Laan, G. van der

    2009-06-22

    Ordering of Fe{sup 3+} and Fe{sup 2+} between octahedral (Oh) and tetrahedral (Td) sites in synthetic members of the magnetite (Fe{sub 3}O{sub 4}) - ulvoespinel (Fe{sub 2}TiO{sub 4}) solid-solution series was determined using Fe L{sub 2,3}-edge X-ray magnetic circular dichroism (XMCD) coupled with electron microprobe and chemical analysis, Ti L-edge spectroscopy, Fe K-edge EXAFS and XANES, Fe{sub 57} Moessbauer spectroscopy, and unit cell parameters. Microprobe analysis, cell edges and chemical FeO determinations showed that the bulk compositions of the samples were stoichiometric magnetite-ulvoespinel solid-solutions. Surface sensitive XMCD showed that the surfaces of these oxide minerals were more sensitive to redox conditions and some samples required re-equilibration with suitable solid-solid buffers. Detailed site-occupancy analysis of these samples gave XMCD-Fe{sup 2+}/Fe{sup 3+} ratios very close to stoichiometric values. L{sub 2,3}-edge spectroscopy showed that Ti{sup 4+} was restricted to Oh sites. XMCD results showed that significant Fe{sup 2+} only entered Td when the Ti content was > 0.40 apfu while Fe{sup 2+} in Oh increased from 1 a.p.f.u in magnetite to a maximum of {approx}1.4 apfu in USP45. As the Ti content increased from this point, the steady increase in Fe{sup 2+} in Td sites was clearly observable in the XMCD spectra, concurrent with a slow decrease in Fe{sup 2+} in Oh sites. Calculated magnetic moments showed a steady decrease from magnetite (4.06 {mu}{sub B}) to USP45 (1.5 {mu}{sub B}) and then a slower decrease towards the value for ulvoespinel (0 {mu}{sub B}). Two of the synthesized samples were also partially maghemitized by re-equilibrating with an oxidizing Ni-NiO buffer and XMCD showed that Fe{sup 2+} oxidation only occurred at Oh sites, with concomitant vacancy formation restricted to this site. This study shows the advantage of using XMCD as a direct measurement of Fe oxidation state in these complex magnetic spinels. These results can be used to rationalize the magnetic properties of titanomagnetites, and their oxidized titanomaghemitized analogues, in Earth's crustal rocks.

  14. A Formaldehyde Exposure Assessment Tool for Occupants of FEMA Temporary Housing Units

    E-Print Network [OSTI]

    Parthasarathy, Srinandini

    2011-01-01

    zip file with the output formaldehyde concentrations andEmission Factors For Formaldehyde and Other Volatile OrganicTests Reveal High Formaldehyde Levels in FEMA Trailers.

  15. Impact of fuel cladding failure events on occupational radiation exposures at nuclear power plants. Case study: PWR during routine operations

    SciTech Connect (OSTI)

    Moeller, M.P.; Martin, G.F.; Haggard, D.L.

    1986-01-01

    The purpose of this report is to present data in support of evaluating the impact of fuel cladding failure events on occupational radiation exposure. To determine quantitatively whether fuel cladding failure contributes significantly to occupational radiation exposure, radiation exposure measurements were taken at comparable locations in two mirror-image pressurized-water reactors (PWRs) and their common auxiliary building. One reactor, Unit B, was experiencing degraded fuel characterized as 0.125% fuel pin-hole leakers and was operating at approximately 55% of the reactor's licensed maximum core power, while the other reactor, Unit A, was operating under normal conditions with less than 0.01% fuel pin-hole leakers at 100% of the reactor's licensed maximum core power. Measurements consisted of gamma spectral analyses, radiation exposure rates and airborne radionuclide concentrations. In addition, data from primary coolant sample results for the previous 20 months on both reactor coolant systems were analyzed. The results of the measurements and coolant sample analyses suggest that a 3560-megawatt-thermal (1100 MWe) PWR operating at full power with 0.125% failed fuel can experience an increase of 540% in radiation exposure rates as compared to a PWR operating with normal fuel. In specific plant areas, the degraded fuel may elevate radiation exposure rates even more.

  16. High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 7. Revision 1

    SciTech Connect (OSTI)

    Burt, D.L.

    1994-04-01

    The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Identification Document (S/RID) is contained in multiple volumes. This document (Volume 7) presents the standards and requirements for the following sections: Occupational Safety and Health, and Environmental Protection.

  17. High PRF high current switch

    DOE Patents [OSTI]

    Moran, Stuart L. (Fredericksburg, VA); Hutcherson, R. Kenneth (College Park, MD)

    1990-03-27

    A triggerable, high voltage, high current, spark gap switch for use in pu power systems. The device comprises a pair of electrodes in a high pressure hydrogen environment that is triggered by introducing an arc between one electrode and a trigger pin. Unusually high repetition rates may be obtained by undervolting the switch, i.e., operating the trigger at voltages much below the self-breakdown voltage of the device.

  18. 2011 Fall : Highly Distinguished Honors Highly Distinguished

    E-Print Network [OSTI]

    Kunkle, Tom

    Distinguished Beidler Katilyn V. Highly Distinguished Belanger Brett Russell Highly Distinguished Bell Lauren Ashley Highly Distinguished Bennett Caitlin Renee Highly Distinguished Berdusco Ann Marie Highly Highly Distinguished Bertel Jeffrey Robert Highly Distinguished Bettendorf Caitlin Marie Highly

  19. This sheet has sample occupations, work settings, employers, and career development activities associated with this major. Some of these options may require additional training and career planning. You are not limited to these options when choosing a poss

    E-Print Network [OSTI]

    Ronquist, Fredrik

    Practitioner Obstetrical Nurse Orderly Pediatric Nurse Physician Nurse Registered Nurse School Nurse SampleNursing This sheet has sample occupations, work settings, employers, and career development Available · Revised 3/14 Sample Occupations Clinical Nurse College/University Faculty Community Health

  20. 2012 Spring : Highly Distinguished Honors Highly Distinguished

    E-Print Network [OSTI]

    Kunkle, Tom

    Distinguished Bell Lauren Ashley Highly Distinguished Benjamin Abigail Highly Distinguished Benson Alexandrea Hannah Elizabeth Highly Distinguished Bishop Anna Laurel Highly Distinguished Black Caitlin Emily Highly

  1. 2014 Fall : Highly Distinguished Honors Highly Distinguished

    E-Print Network [OSTI]

    Kunkle, Tom

    Morgan Highly Distinguished Beech Kaylie Schaefer Highly Distinguished Bell Brandi Lakeisha Highly Distinguished Billard Caitlin Rose Highly Distinguished Birk Christian Gustave Highly Distinguished Birkhead

  2. Evaluation and Control of Radiation Dose to the Embryo/Fetus Guide for Use with Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1999-04-29

    This Guide provides an acceptable methodology for establishing and operating a program to control fetal exposure to ionizing radiation and evaluate the resultant dose that will comply with U.S. Department of Energy (DOE) requirements specified in Title 10 of the Code of Federal Regulations (CFR), Part 835, Occupational Radiation Protection (DOE 1998), hereinafter referred to as 10 CFR 835.

  3. Posting and Labeling for Radiological Control Guide for use with Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1999-05-24

    This Guide provides an acceptable methodology for establishing and operating a radiological hazard posting and labeling program that will comply with U.S. Department of Energy (DOE) requirements specified in Title 10 of the Code of Federal Regulations (CFR), Part 835, Occupational Radiation Protection Canceled by DOE G 441.1-1B.

  4. Management and Administration of Radiation Protection Programs Guide for use with Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2003-10-20

    This Guide discusses acceptable methods for ensuring that radiological activities will be managed and administered in accordance with a documented radiation protection program that complies with U.S. DOE requirements specified in Title 10 CFR Part 835, Occupational Radiation Protection. Cancels DOE G 441.1-1. Canceled by DOE G 441.1-1B.

  5. Information on this page was compiled from the Occupational Outlook Handbook, the Encyclopedia of Careers and Vocational Guidance, University of Minnesota departmental websites, and student-reported data.

    E-Print Network [OSTI]

    Weiblen, George D

    Information on this page was compiled from the Occupational Outlook Handbook, the Encyclopedia. WHAT CAN I DO WITH A MAJOR IN: Activities Biology Majors Do Biological scientists study living, bacteria, and other infectious agents. Biological scientists who work in applied research or product

  6. Sensing by Proxy: Occupancy Detection Based on Indoor CO2 Concentration Ming Jin, Nikolaos Bekiaris-Liberis, Kevin Weekly, Costas Spanos, Alexandre Bayen

    E-Print Network [OSTI]

    Sensing by Proxy: Occupancy Detection Based on Indoor CO2 Concentration Ming Jin, Nikolaos Bekiaris on indoor CO2 concentration. We propose a link model that relates the proxy measurements with unknown human, small particulates (PM2.5), CO2, illumi- nation, temperature, and humidity [6], [8], [9]. Indoor CO2

  7. Occupational and patient exposure as well as image quality for full spine examinations with the EOS imaging system

    SciTech Connect (OSTI)

    Damet, J., E-mail: jerome.damet@chuv.ch; Fournier, P.; Monnin, P.; Sans-Merce, M.; Verdun, F. R.; Baechler, S. [Institute of Radiation Physics, Lausanne University Hospital, Lausanne 1007 (Switzerland)] [Institute of Radiation Physics, Lausanne University Hospital, Lausanne 1007 (Switzerland); Ceroni, D. [Department of Paediatrics, Division of paediatric orthopaedic, University Hospitals of Geneva, Geneva 1205 (Switzerland)] [Department of Paediatrics, Division of paediatric orthopaedic, University Hospitals of Geneva, Geneva 1205 (Switzerland); Zand, T. [Department of Radiology, Division of paediatric radiology, University Hospitals of Geneva, Geneva 1205 (Switzerland)] [Department of Radiology, Division of paediatric radiology, University Hospitals of Geneva, Geneva 1205 (Switzerland)

    2014-06-15

    Purpose: EOS (EOS imaging S.A, Paris, France) is an x-ray imaging system that uses slot-scanning technology in order to optimize the trade-off between image quality and dose. The goal of this study was to characterize the EOS system in terms of occupational exposure, organ doses to patients as well as image quality for full spine examinations. Methods: Occupational exposure was determined by measuring the ambient dose equivalents in the radiological room during a standard full spine examination. The patient dosimetry was performed using anthropomorphic phantoms representing an adolescent and a five-year-old child. The organ doses were measured with thermoluminescent detectors and then used to calculate effective doses. Patient exposure with EOS was then compared to dose levels reported for conventional radiological systems. Image quality was assessed in terms of spatial resolution and different noise contributions to evaluate the detector's performances of the system. The spatial-frequency signal transfer efficiency of the imaging system was quantified by the detective quantum efficiency (DQE). Results: The use of a protective apron when the medical staff or parents have to stand near to the cubicle in the radiological room is recommended. The estimated effective dose to patients undergoing a full spine examination with the EOS system was 290?Sv for an adult and 200 ?Sv for a child. MTF and NPS are nonisotropic, with higher values in the scanning direction; they are in addition energy-dependent, but scanning speed independent. The system was shown to be quantum-limited, with a maximum DQE of 13%. The relevance of the DQE for slot-scanning system has been addressed. Conclusions: As a summary, the estimated effective dose was 290?Sv for an adult; the image quality remains comparable to conventional systems.

  8. Changes in the peripheral blood transcriptome associated with occupational benzene exposure identified by cross-comparison on two microarray platforms

    SciTech Connect (OSTI)

    McHale, Cliona M.; Zhang, Luoping; Lan, Qing; Li, Guilan; Hubbard, Alan E.; Forrest, Matthew S.; Vermeulen, Roel; Chen, Jinsong; Shen, Min; Rappaport, Stephen M.; Yin, Songnian; Smith, Martyn T.; Rothman, Nathaniel

    2009-03-01

    Benzene is an established cause of leukemia and a possible cause of lymphoma in humans but the molecular pathways underlying this remain largely undetermined. This study sought to determine if the use of two different microarray platforms could identify robust global gene expression and pathway changes associated with occupational benzene exposure in the peripheral blood mononuclear cell (PBMC) gene expression of a population of shoe-factory workers with well-characterized occupational exposures to benzene. Microarray data was analyzed by a robust t-test using a Quantile Transformation (QT) approach. Differential expression of 2692 genes using the Affymetrix platform and 1828 genes using the Illumina platform was found. While the overall concordance in genes identified as significantly associated with benzene exposure between the two platforms was 26% (475 genes), the most significant genes identified by either array were more likely to be ranked as significant by the other platform (Illumina = 64%, Affymetrix = 58%). Expression ratios were similar among the concordant genes (mean difference in expression ratio = 0.04, standard deviation = 0.17). Four genes (CXCL16, ZNF331, JUN and PF4), which we previously identified by microarray and confirmed by real-time PCR, were identified by both platforms in the current study and were among the top 100 genes. Gene Ontology analysis showed over representation of genes involved in apoptosis among the concordant genes while Ingenuity{reg_sign} Pathway Analysis (IPA) identified pathways related to lipid metabolism. Using a two-platform approach allows for robust changes in the PBMC transcriptome of benzene-exposed individuals to be identified.

  9. SHORT COMMUNICATION Habitat patch size and isolation as predictors of occupancy

    E-Print Network [OSTI]

    Agnarsson, Ingi

    of argyrodine spider kleptoparasites in Nephila webs Ingi Agnarsson Received: 13 October 2010 /Revised: 22. Spider webs as habitat patches for obligate web kleptoparasites are free from these problems. Each individ- ual web is a highly discrete and readily measured habitat patch, and the detection probability

  10. Indoor airborne bacterial communities are influenced by ventilation, occupancy, and outdoor air source

    E-Print Network [OSTI]

    Bohannan, Brendan

    , is an energy-efficient way to simultaneously cool building mass and avoid overnight and weekend microbial an intensive temporal study of indoor airborne bacterial communities in a high-traffic university building associated with differing ventilation strategies relevant to modern building design. Our results indicate

  11. Very extended shapes in 108Cd: evidence for the occupation of 'hyper-intruder' orbitals

    SciTech Connect (OSTI)

    Gorgen, A.; Clark, R.M.; Fallon, P.; Cromaz, M.; Deleplanque, M.A.; Diamond, R.M.; Lane, G.J.; Lee, I.Y.; Macchiavelli, A.O.; Ramos, R.G.; Stephens, F.S.; Svensson, C.E.; Vetter, K.; Ward, D.; Carpenter, M.P.; Janssens, R.V.F.; Wadsworth, R.

    2002-07-01

    High-spin states in {sup 108}Cd were studied following the reaction {sup 64} Ni({sup 48}Ca,4n) at a beam energy of 207 MeV. Gamma rays were detected using the Gammasphere array. Two rotational bands have been observed at very high angular momentum. Measurements of fractional Doppler shifts yielded lower limits for the quadrupole moments and showed that the observed structures are at least as deformed as the superdeformed structures e.g. in the A {approx} 150 region, and possibly exceed a 2:1 axis ratio. The existence of very extended shapes has been predicted by cranked Strutinsky calculations, and recent projected shell model calculations suggest that the {pi}i{sub 13/2}hyper-intruder orbital is occupied in these newly observed bands.

  12. Occupational Health Services - HPMC Occupational Health Services

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    exercise physiology and work conditioning, monitored care and case management, fitness for duty evaluations, health education and wellness promotion, infection control,...

  13. Energy Employees Occupational Illness Compensation Program Act (EEOICPA) Tracking System PIA

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on DeliciousMathematics And StatisticsProgramof-SA-02:Innovative Energy Apps Built withRecord HighsDepartment ofProgram |

  14. NIOSH (National Institute for Occupational Safety and Health) testimony to DOL (Department of Labor) on the Occupational Safety and Health Administration's proposed rule on the control of hazardous energy sources (lockout/tagout) by R. W. Niemeier, September 8, 1988

    SciTech Connect (OSTI)

    Not Available

    1988-09-08

    The testimony addressed the proposed rule on control of hazardous energy sources and was offered in support of the position of the Occupational Safety and Health Administration on this issue. Provisions already in existence for cranes, derricks, and power presses require lockout provisions for electrical connections. The proposed rule will extend these protections to nonelectric power sources and add a requirement for isolating nonelectric hazards. The new rule requires a written procedure and training program. NIOSH opposed the use of tags instead of locks, as tags only provide a warning and are subject to several abuses including removal before maintenance is complete and negligence in removing the tag by the service operator when maintenance is completed. Over 20 electrically related fatalities were noted where a deenergized locked-out electrical circuit would have prevented the fatality. In a review of 160 responses concerning injuries where the equipment was turned off, six indicated the equipment was tagged out. Concern was also expressed over the simple tagout permitted for mechanical power transmission systems. NIOSH recommends that each worker should apply and remove his or her own lock.

  15. Delocalization and occupancy effects of 5f orbitals in plutonium intermetallics using L3-edge resonant X-ray emission spectroscopy

    SciTech Connect (OSTI)

    Booth, C. H.; Medling, S. A.; Jiang, Yu; Bauer, E. D.; Tobash, P. H.; Mitchell, J. N.; Veirs, D. K.; Wall, M. A.; Allen, P. G.; Kas, J. J.; Sokaras, D.; Nordlund, D.; Weng, T.-C.

    2014-06-24

    Although actinide (An) L3 -edge X-ray absorption near-edge structure (XANES) spectroscopy has been very effective in determining An oxidation states in insulating, ionically bonded materials, such as in certain coordination compounds and mineral systems, the technique fails in systems featuring more delocalized 5f orbitals, especially in metals. Recently, actinide L3-edge resonant X-ray emission spec- troscopy (RXES) has been shown to be an effective alternative. This technique is further demonstrated here using a parameterized partial unoccupied density of states method to quantify both occupancy and delocalization of the 5f orbital in ?-Pu, ?-Pu, PuCoGa5 , PuCoIn5 , and PuSb2. These new results, supported by FEFF calculations, highlight the effects of strong correlations on RXES spectra and the technique?s ability to differentiate between f-orbital occupation and delocalization.

  16. Occupational dose reduction at Department of Energy contractor facilities. Study of ALARA programs: Good practice documents: Appendices

    SciTech Connect (OSTI)

    Dionne, B.J.; Meinhold, C.B.; Khan, T.A.; Baum, J.W. [Brookhaven National Lab., Upton, NY (United States)

    1992-08-01

    These appendices are a supplement to the report entitled ``Occupational Dose Reduction at Department of Energy Contractor Facilities: Study of ALARA Programs--Status 1990. `` The report describes the results of a survey conducted at various Department of Energy (DOE) contractor facilities during 1989 and 1990 to assess the current status of ALARA program implementation. This supplement to that report contains examples of generic ``good practice`` documents typically associated with implementing the major elements of a formally documented ALARA program at a major DOE contractor facility. These good practice ALARA program documents were developed based on the best representative examples from the visited contractor facilities, supplemented as necessary with examples from the commercial nuclear industry. Other techniques, methods or practices may be as good or better (the authors would appreciate hearing or receiving information about them). These good practice documents are provided as an optional resource for incorporation into existing contractor ALARA programs. It should be noted that these documents were developed prior to the issuance of the Department of Energy Radiological Control (RadCon) Manual, and consequently do not reflect in all instance`s the requirements or specific terminology of that manual. These good practice documents were also designed to be consistent with current DOE Order requirements, where applicable; however, subsequent revisions to DOE Orders may make these documents outdated. The user should consequently review and update these good practice documents against the requirements of the RadCon Manual and against any revisions to applicable DOE Orders prior to their implementation.

  17. Effects of multiple occupancy and inter-particle interactions on selective transport through narrow channels: theory versus experiment

    E-Print Network [OSTI]

    Anton Zilman

    2008-11-17

    Many biological and artificial transport channels function without direct input of metabolic energy during a transport event and without structural rearrangements involving transitions from a 'closed' to an 'open' state. Nevertheless, such channels are able to maintain efficient and selective transport. It has been proposed that attractive interactions between the transported molecules and the channel can increase the transport efficiency and that the selectivity of such channels can be based on the strength of the interaction of the specifically transported molecules with the channel. Herein, we study the transport through narrow channels in a framework of a general kinetic theory, which naturally incorporates multi-particle occupancy of the channel and non-single-file transport. We study how the transport efficiency and the probability of translocation through the channel are affected by inter-particle interactions in the confined space inside the channel, and establish conditions for selective transport. We compare the predictions of the model with the available experimental data - and find good semi-quantitative agreement. Finally, we discuss applications of the theory to the design of artificial nano-molecular sieves.

  18. The relative variational model - A topological view of matter and its properties: Space occupancy by the atoms

    SciTech Connect (OSTI)

    Dias, M. S. [Center for Development of the Nuclear Technology - CDTN, National Commission for the Nuclear Energy - CNEN, PO Box: 941, 30.161-970, Belo Horizonte, Minas Gerais (Brazil); De Vasconcelos, V.; Mattos, J. R. L. [Center for Development of the Nuclear Technology - CDTN, National Commission for the Nuclear Energy - CNEN (Brazil); Jordao, E. [Chemistry Engineering Dept., Campinas State Univ., FEQ/ UNICAMP, Av. Albert Einstein, 500, 13083-852, Campinas, Sao Paulo (Brazil)

    2012-07-01

    Formal definitions of convergence, connected-ness and continuity were established to characterize and describe the crystalline solid and its properties as a unified notion in the topological space. In this unified notion, physical and material properties are modeled by means of an intrinsic and invariable form function: the Relative Variational Model. The crystalline solid is assumed an empty space that has been filled with atoms and phonons, i.e., the crystal is built with packages of matter and energy in a regular and orderly repetitive pattern along three orthogonal dimensions of the space. The spatial occupation of the atom in the crystalline structure is determined by its mean vibrational volume, which also defines the lattice parameter or interatomic distance. However, as packages of vibrational energy, phonons can only exist as vibrations of atoms. Any variation of internal energy is in fact the discretized variations of phonon's population. These variations occur in the quantized modes of vibration, and therefore the balance between the frequency and amplitude of vibrations also is a dynamic variable. In this paper, the Relative Variational Model was applied to de-convolutions of frequency spectra of the inelastic neutron scatterings. Some dynamic aspects of atom vibration were presented and evaluated in support to the model's fundamentals. (authors)

  19. Management and Administration of Radiation Protection Programs Guide for Use with Title 10, Code of Federal Regulations, Part 835, Occupational Radiation Protection

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1999-03-17

    This Guide discusses acceptable methods for ensuring that radiological activities will be managed and administered in accordance with a documented radiation protection program (RPP) that complies with U.S. Department of Energy (DOE) requirements specified in Title 10 of the Code of Federal Regulations (CFR), Part 835, Occupational Radiation Protection (DOE 1998a), hereinafter referred to as 10 CFR 835. Canceled by DOE G 441.1-1A.

  20. This sheet has sample occupations, work settings, employers, and career development activities associated with this major. Some of these options may require additional training and career planning. You are not limited to these options when choosing a poss

    E-Print Network [OSTI]

    Ronquist, Fredrik

    activities associated with this major. Some of these options may require additional training and career planning. You are not limited to these options when choosing a possible career path. Sample Occupations Real Estate Development: The ULI Guide to the Business.................

  1. This sheet has sample occupations, work settings, employers, and career development activities associated with this major. Some of these options may require additional training and career planning. You are not limited to these options when choosing a poss

    E-Print Network [OSTI]

    Ronquist, Fredrik

    Assistant Occupational Specialist Principal School Nurse School Social Worker Speech-Language Pathologist Agencies Adult Literacy Programs Alternative Schools Athletic Clubs Boards of Education Camps Churches/HMOs International Schools Libraries Nursing Homes/Retirement Communities Parks & Recreation Departments Political

  2. The Department of Energy`s Rocky Flats Plant: A guide to record series useful for health-related research. Volume VII. Employee occupational exposure and health

    SciTech Connect (OSTI)

    1995-08-01

    This is the seventh in a series of seven volumes which constitute a guide to records of the Rocky Flats Plant useful for conducting health-related research. The primary purpose of Volume VII is to describe record series pertaining to employee occupational exposure and health at the Department of Energy`s (DOE) Rocky Flats Plant, now named the Rocky Flats Environmental Technology Site, near Denver, Colorado. History Associates Incorporated (HAI) prepared this guide as part of its work as the support services contractor for DOE`s Epidemiologic Records Inventory Project. This introduction briefly describes the Epidemiologic Records Inventory Project and HAI`s role in the project, provides a history of occupational exposure monitoring and health practices at Rocky Flats, and identifies organizations contributing to occupational exposure monitoring and health policies and activities. Other topics include the scope and arrangement of the guide and the organization to contact for access to these records. Comprehensive introductory and background information is available in Volume 1. Other volumes in the guide pertain to administrative and general subjects, facilities and equipment, production and materials handling, environmental and workplace monitoring, and waste management. In addition, HAI has produced a subject-specific guide, titled The September 1957 Rocky Flats Fire: A Guide to Record Series of the Department of Energy and Its Contractors, which researchers should consult for further information about records related to this incident.

  3. High-level waste storage tank farms/242-A evaporator standards/requirements identification document (S/RID), Vol. 7

    SciTech Connect (OSTI)

    Not Available

    1994-04-01

    This Requirements Identification Document (RID) describes an Occupational Health and Safety Program as defined through the Relevant DOE Orders, regulations, industry codes/standards, industry guidance documents and, as appropriate, good industry practice. The definition of an Occupational Health and Safety Program as specified by this document is intended to address Defense Nuclear Facilities Safety Board Recommendations 90-2 and 91-1, which call for the strengthening of DOE complex activities through the identification and application of relevant standards which supplement or exceed requirements mandated by DOE Orders. This RID applies to the activities, personnel, structures, systems, components, and programs involved in maintaining the facility and executing the mission of the High-Level Waste Storage Tank Farms.

  4. Hazardous Materials Handling High Pressure Cylinders

    E-Print Network [OSTI]

    Boynton, Walter R.

    NOT FILL CYLINDERS #12;The US Dept. of Labor, Occupational Safety Health Administration (OSHA) regulates do propose a risk,through proper handling,storage, use and filling the risk may be reduced

  5. Occupational Radiation Exposure at Commercial Nuclear Power Reactors and Other Facilities 2010, Prepared for the Nuclear Regulatory Commission, Office of Nuclear Regulatory Research, May 2012

    SciTech Connect (OSTI)

    D. E. Lewis D. A. Hagemeyer Y. U. McCormick

    2012-07-07

    This report summarizes the occupational exposure data that are maintained in the U.S. Nuclear Regulatory Commission’s (NRC) Radiation Exposure Information and Reporting System (REIRS). The bulk of the information contained in the report was compiled from the 2010 annual reports submitted by five of the seven categories of NRC licensees subject to the reporting requirements of 10 CFR 20.2206. Because there are no geologic repositories for high-level waste currently licensed and no NRC-licensed low-level waste disposal facilities currently in operation, only five categories will be considered in this report. The annual reports submitted by these licensees consist of radiation exposure records for each monitored individual. These records are analyzed for trends and presented in this report in terms of collective dose and the distribution of dose among the monitored individuals. Annual reports for 2010 were received from a total of 190 NRC licensees. The summation of reports submitted by the 190 licensees indicated that 192,424 individuals were monitored, 81,961 of whom received a measurable dose. When adjusted for transient workers who worked at more than one licensee during the year, there were actually 142,471 monitored individuals and 62,782 who received a measurable dose. The collective dose incurred by these individuals was 10,617 person-rem, which represents a 12% decrease from the 2009 value. This decrease was primarily due to the decrease in collective dose at commercial nuclear power reactors, as well as a decrease in the collective dose for most of the other categories of NRC licensees. The number of individuals receiving a measurable dose also decreased, resulting in an average measurable dose of 0.13 rem for 2010. The average measurable dose is defined as the total effective dose equivalent (TEDE) divided by the number of individuals receiving a measurable dose. In calendar year 2010, the average annual collective dose per reactor for light water reactor (LWR) licensees was 83 person-rem. This represents a 14% decrease from the value reported for 2009 (96 person-rem). The decrease in collective dose for commercial nuclear power reactors was due to an 11% decrease in total outage hours in 2010. During outages, activities involving increased radiation exposure such as refueling and maintenance are performed while the reactor is not in operation. The average annual collective dose per reactor for boiling water reactors (BWRs) was 137 personrem for 35 BWRs, and 55 person-rem for 69 pressurized water reactors (PWRs). Analyses of transient individual data indicate that 29,333 individuals completed work assignments at two or more licensees during the monitoring year. The dose distributions are adjusted each year to account for the duplicate reporting of transient individuals by multiple licensees. The adjustment to account for transient individuals has been specifically noted in footnotes in the figures and tables for commercial nuclear power reactors. In 2010, the average measurable dose per individual for all licensees calculated from reported data was 0.13 rem. Although the average measurable dose per individual from data submitted by licensees was 0.13 rem, a corrected dose distribution resulted in an average measurable dose per individual of 0.17 rem.

  6. Occupational Safety Performance Trends

    Broader source: Energy.gov [DOE]

    DOE Quarterly TRC and DART Case Rates EM Quarterly TRC and DART Case Rates NNSA Quarterly TRC and DART Case Rates SC Quarterly TRC and DART Case Rates

  7. Council's Occupational Excellence Achievement

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration would like submit the followingConcentratingPortalCoolCoronaryCosts Associated4-Year Study.

  8. Occupational Safety Performance

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirley Ann Jackson About1996How to ApplytheExecutive71.1 OMB ControlOakDOE's Priorities |

  9. Occupational Medicine Variance Request

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration wouldMass mapSpeeding access to scienceSpeedingLightweightand SimulatedIII Contractand

  10. HPMC Occupational Health Services

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration would likeUniverse (Journalvivo Low-Dose Low34 Revision 0 ApprovedD2SADeputy Group Lead6,5,

  11. Program desk manual for occupational safety and health -- U.S. Department of Energy Richland Operations, Office of Environment Safety and Health

    SciTech Connect (OSTI)

    Musen, L.G.

    1998-08-27

    The format of this manual is designed to make this valuable information easily accessible to the user as well as enjoyable to read. Each chapter contains common information such as Purpose, Scope, Policy and References, as well as information unique to the topic at hand. This manual can also be provided on a CD or Hanford Internet. Major topics include: Organization and program for operational safety; Occupational medicine; Construction and demolition; Material handling and storage; Hoisting and rigging; Explosives; Chemical hazards; Gas cylinders; Electrical; Boiler and pressure vessels; Industrial fire protection; Industrial hygiene; and Safety inspection checklist.

  12. Field Demonstration of High Efficiency Gas Heaters | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    to building occupants. Unit heaters are a major source of energy use nationally, accounting for nearly 18% of primary space heating energy use for commercial buildings, and...

  13. Highly Insulating Residential Windows Using Smart Automated Shading...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    sensormicroprocessor package that is easily installed and calibrated. Control algorithms will be developed that focus on maximum energy savings, while keeping occupants...

  14. Essays on High School Accountability and College Readiness

    E-Print Network [OSTI]

    Lee, Joanne

    2011-01-01

    Math” C: Mid Algebra I, Geometry, 1-2No math General, Consumer, Pre-Algebra, Occupationally-B”) encompasses pre-algebra or vocational math. The courses

  15. High Temperatures & Electricity Demand

    E-Print Network [OSTI]

    High Temperatures & Electricity Demand An Assessment of Supply Adequacy in California Trends.......................................................................................................1 HIGH TEMPERATURES AND ELECTRICITY DEMAND.....................................................................................................................7 SECTION I: HIGH TEMPERATURES AND ELECTRICITY DEMAND ..........................9 BACKGROUND

  16. High-Temperature-High-Volume Lifting for Enhanced Geothermal...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems High-Temperature-High-Volume Lifting for...

  17. ACCESS Magazine Fall 2007

    E-Print Network [OSTI]

    2007-01-01

    London, Singapore, and Stockholm—spend their toll revenue on public transportation,Transportation Taxes: Devolution as Revolution Martin Wachs High-Speed Rail Comes to London

  18. A Post-Occupancy Monitored Evaluation of the Dimmable Lighting, Automated Shading, and Underfloor Air Distribution System in The New York Times Building

    SciTech Connect (OSTI)

    Lee, E. S.; Fernandes, L. L.; Coffey, B.; McNeil, A.; Clear, R.; Webster, T.; Bauman, F.; Dickerhoff, D.; Heinzerling, D.; Hoyt, T.

    2013-01-01

    With aggressive goals to reduce national energy use and carbon emissions, the U.S. Department of Energy (DOE) will be looking to exemplary buildings that have already invested in new approaches to achieving the energy performance goals now needed at a national level. The New York Times Building, in New York, New York, incorporates a number of innovative technologies, systems and processes and could become model for widespread replication in new and existing buildings. A year-long monitored study was conducted to verify energy performance, assess occupant comfort and satisfaction with the indoor environment, and evaluate impact on maintenance and operations. Lessons learned were derived from the analysis; these lessons could help identify and shape policy, financial, or supporting strategies to accelerate diffusion in the commercial building market.

  19. This sheet has sample occupations, work settings, employers, and career development activities associated with this major. Some of these options may require additional training and career planning. You are not limited to these options when choosing a poss

    E-Print Network [OSTI]

    Ronquist, Fredrik

    Society - New York, NY www.amergeog.org American Planning Association - Chicago, IL www of Commerce Department of Defense Department of Energy Department of Health & Human Services Department Alternative Format Available · Revised 3/14 Connecting Majors, Skills, and Occupations · View learning

  20. Information on this page was compiled from the Occupational Outlook Handbook, the Encyclopedia of Careers and Vocational Guidance, Society for Neuroscience, University of Minnesota departmental websites, and student-reported data.

    E-Print Network [OSTI]

    Weiblen, George D

    Information on this page was compiled from the Occupational Outlook Handbook, the Encyclopedia is a field of study that employs the tools and perspectives of biology, psychology, chemistry, physics now to address these basic issues directly at the molecular level. Many aspects of the biological

  1. Information on this page was compiled from the Occupational Outlook Handbook, the Encyclopedia of Careers and Vocational Guidance, University of Minnesota departmental websites, What Can You Do With a Major in Biology?, and student-reported data.

    E-Print Network [OSTI]

    Weiblen, George D

    Information on this page was compiled from the Occupational Outlook Handbook, the Encyclopedia With a Major in Biology?, and student-reported data. WHAT CAN I DO WITH A MAJOR IN: Activities Plant Biology. A bachelor's degree in plant biology provides a solid foundation for advanced professional degrees

  2. Topics in Microeconometrics: Estimation of a Dynamic Model of Occupational Transitions, Wage and Non-Wage Benefits Cross Validation Bandwidth Selection for Derivatives of Various Dimensional Densities Testing the Additive Separability of the Teacher Value Added Effect Semiparametrically

    E-Print Network [OSTI]

    Baird, Matthew David

    2012-01-01

    bene?ts to o?set new occupation entry costs, and to di?erentM k is the entry cost associated with starting a new job. wbetween new job o?ers to choose between, and the entry cost

  3. The impact of fuel cladding failure events on occupational radiation exposures at nuclear power plants: Case study, PWR (pressurized-water reactor) during an outage

    SciTech Connect (OSTI)

    Moeller, M.P.; Martin, G.F.; Kenoyer, J.L.

    1987-08-01

    This report is the second in a series of case studies designed to evaluate the magnitude of increase in occupational radiation exposures at commercial US nuclear power plants resulting from small incidents or abnormal events. The event evaluated is fuel cladding failure, which can result in elevated primary coolant activity and increased radiation exposure rates within a plant. For this case study, radiation measurements were made at a pressurized-water reactor (PWR) during a maintenance and refueling outage. The PWR had been operating for 22 months with fuel cladding failure characterized as 105 pin-hole leakers, the equivalent of 0.21% failed fuel. Gamma spectroscopy measurements, radiation exposure rate determinations, thermoluminescent dosimeter (TLD) assessments, and air sample analyses were made in the plant's radwaste, pipe penetration, and containment buildings. Based on the data collected, evaluations indicate that the relative contributions of activation products and fission products to the total exposure rates were constant over the duration of the outage. This constancy is due to the significant contribution from the longer-lived isotopes of cesium (a fission product) and cobalt (an activation product). For this reason, fuel cladding failure events remain as significant to occupational radiation exposure during an outage as during routine operations. As documented in the previous case study (NUREG/CR-4485 Vol. 1), fuel cladding failure events increased radiation exposure rates an estimated 540% at some locations of the plant during routine operations. Consequently, such events can result in significantly greater radiation exposure rates in many areas of the plant during the maintenance and refueling outages than would have been present under normal fuel conditions.

  4. Network Based Evaluation Method for Financial Analysis of Toll Roads 

    E-Print Network [OSTI]

    Vajdic, Nevena

    2011-02-22

    common financial instruments were analyzed: bank loans, bonds and real options. Emphasis of the financial feasibility assessment was on the price of the revenue risk, as the most important risk in public private partnership agreements. Results have shown...

  5. Optimal Toll Design: A Lower Bound Framework for the Asymmetric ...

    E-Print Network [OSTI]

    2012-12-24

    is, the cost-to-go assigns individual costs to each remaining city plus the ..... However, the optimization can actually be carried out in linear time because t is constant: For ..... Gas Storage Valuation Based on Approximate Linear Programming ...

  6. Modulators of Toll-like Receptors-4 and -2

    E-Print Network [OSTI]

    Wu, Wenyan

    2009-08-31

    ?OEt2 – boron trifluoride diethyl etherate BnBr – benzyl bromide br - broad Boc – di-tert-butyl carbonate BPI – bactericidal permeability increasing protein CH3CN – acetonitrile C15H31COCl – palmitoyl chloride CTL – cytotoxic T lymphocyte DAB...

  7. Federal program for regulating highly hazardous materials finally takes off

    SciTech Connect (OSTI)

    Lessard, P.C. [Block Environmental Services Inc., Pleasant Hill, CA (United States)

    1996-11-01

    The Risk Management Program (RMP) rule, Section 112(r) of the Clean Air Act (CAA), was signed on May 24 and finalized on June 20. RMP is one of the most comprehensive, technically based regulatory programs for preventing, detecting and responding to accidental hazardous materials releases to have been issued in recent times. Although facilities have three years to comply, EPA estimates that the rule will affect an estimated 66,000 facilities that store highly hazardous or acutely toxic materials. The 1990 CAA Amendments are designed to prevent accidental releases of highly hazardous chemicals from stationary sources. Two significant regulatory programs that have emerged from the revised CAA are the Process Safety Management (PSM) standard and RMP. PSM is designed to protect employees and regulated by the Occupational Safety and Health Administration. RMP`s purpose is to protect the public and the environment from highly hazardous chemicals. It authorizes EPA to create a list of substances (distinct from the list generated under PSM) known to cause serious adverse effects and to implement a program for accidental chemical release prevention.

  8. High efficiency and high concentration in photovoltaics

    SciTech Connect (OSTI)

    Yamaguchi, Masafumi; Luque, A.

    1999-10-01

    In this paper, the authors present the state-of-the-art of multijunction solar cells and the future prospects of this technology. Their use in terrestrial applications will likely be for concentrators operating at very high concentrations. Some trends are also discussed and the authors present a cost calculation showing that highly efficient cells under very high concentration would be able to produce electricity at costs competitive with electricity generation costs for some utilities.

  9. High Performance Computing

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    HPC INL Logo Home High-Performance Computing INL's high-performance computing center provides general use scientific computing capabilities to support the lab's efforts in advanced...

  10. High Performance Computing

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Computing HPC High Performance Computing (HPC) Providing world-class high performance computing capability that enables unsurpassed solutions to complex problems of strategic...

  11. The Advantage of Highly Controlled Lighting for Offices and Commercial Buildings

    SciTech Connect (OSTI)

    Rubinstein, Francis; Bolotov, Dmitriy; Levi, Mark; Powell, Kevin; Schwartz, Peter

    2008-08-17

    The paper presents results from pilot studies of new 'workstation-specific' luminaires that are designed to provide highly, efficient, customized lighting for open-office cubicles. Workstation specific luminaires have the following characteristics: (1) they provide separate, dimming control of the cubicle's 'ambient' and 'task' lighting components, (2) occupancy sensors and control photosensors are integrated into the fixture's design and operation, (3) luminaires can be networked using physical cabling, microcontrollers and a PC running control software. The energy savings, demand response capabilities and quality of light from the two WS luminaires were evaluated and compared to the performance of a static, low-ambient lighting system that is uncontrolled. Initial results from weeks of operation provide strong indication that WS luminaires can largely eliminate the unnecessary lighting of unoccupied cubicles while providing IESNA-required light levels when the cubicles are occupied. Because each cubicle's lighting is under occupant sensor control, the WS luminaires can capitalize on the fact cubicles are often unoccupied during normal working hours and reduce their energy use accordingly.

  12. High pressure, high current, low inductance, high reliability sealed terminals

    DOE Patents [OSTI]

    Hsu, John S. (Oak Ridge, TN) [Oak Ridge, TN; McKeever, John W. (Oak Ridge, TN) [Oak Ridge, TN

    2010-03-23

    The invention is a terminal assembly having a casing with at least one delivery tapered-cone conductor and at least one return tapered-cone conductor routed there-through. The delivery and return tapered-cone conductors are electrically isolated from each other and positioned in the annuluses of ordered concentric cones at an off-normal angle. The tapered cone conductor service can be AC phase conductors and DC link conductors. The center core has at least one service conduit of gate signal leads, diagnostic signal wires, and refrigerant tubing routed there-through. A seal material is in direct contact with the casing inner surface, the tapered-cone conductors, and the service conduits thereby hermetically filling the interstitial space in the casing interior core and center core. The assembly provides simultaneous high-current, high-pressure, low-inductance, and high-reliability service.

  13. HIGH-POWER, HIGH-EFFICIENCY FELS

    E-Print Network [OSTI]

    Sessler, A.M.

    2008-01-01

    M. Kumada, "Scaling of the FEL-ID Equations", ELF Note 128,Instability in a High-power, Short- Wavelength FEL", Proc.of the Ninth FEL" Conference, Williamsburg (1988), and

  14. High strength, high ductility low carbon steel

    DOE Patents [OSTI]

    Koo, Jayoung (Berkeley, CA); Thomas, Gareth (Berkeley, CA)

    1978-01-01

    A high strength, high ductility low carbon steel consisting essentially of iron, 0.05-0.15 wt% carbon, and 1-3 wt% silicon. Minor amounts of other constituents may be present. The steel is characterized by a duplex ferrite-martensite microstructure in a fibrous morphology. The microstructure is developed by heat treatment consisting of initial austenitizing treatment followed by annealing in the (.alpha. + .gamma.) range with intermediate quenching.

  15. Parallel Programming for High-Performance Applications

    E-Print Network [OSTI]

    Bal, Henri E.

    into a rather dull and routine occupation'' · S. Gill, Computer Journal, 1958 #12;Why do we need parallel important #12;Moore's law (1975) · Circuit complexity doubles every 18 months · Exponential transistor machines (Blue Gene) · 2000s: grid computing: combining resources world- wide (Globus) · Now: multicores

  16. Low Cost, High Temperature, High Ripple Current DC Bus Capacitors...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Low Cost, High Temperature, High Ripple Current DC Bus Capacitors Low Cost, High Temperature, High Ripple Current DC Bus Capacitors 2010 DOE Vehicle Technologies and Hydrogen...

  17. Energy Storage Testing and Analysis High Power and High Energy...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Testing and Analysis High Power and High Energy Development Energy Storage Testing and Analysis High Power and High Energy Development 2009 DOE Hydrogen Program and Vehicle...

  18. Large-dimension, high-ZT Thermoelectric Nanocomposites for High...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Large-dimension, high-ZT Thermoelectric Nanocomposites for High-Power High-efficiency Waste Heat Recovery for Electricity Generation Large-dimension, high-ZT Thermoelectric...

  19. High Performance Datacenter Networks

    E-Print Network [OSTI]

    Cortes, Corinna

    High Performance Datacenter Networks Architectures, Algorithms, and Opportunities #12;Synthesis architecture conferences, such as ISCA, HPCA, MICRO, and ASPLOS. High Performance Datacenter Networks Computer Architecture Daniel J. Sorin 2009 The Datacenter as a Computer: An Introduction to the Design

  20. High Performance Liquid Chromatography

    E-Print Network [OSTI]

    Nizkorodov, Sergey

    HPLC MEASUREMENT OF POLYCYCLIC AROMATIC HYDROCARBONS IN CIGARETTE SMOKE INTRODUCTION Even thoughHPLC - 1 High Performance Liquid Chromatography HPLC MEASUREMENT OF POLYCYCLIC AROMATIC HYDROCARBONS IN CIGARETTE SMOKE Last updated: June 17, 2014 #12;HPLC - 2 High Performance Liquid Chromatography

  1. High sensitivity accelerometers are

    E-Print Network [OSTI]

    Lee, Dongwon

    metamaterial - high-permittivity dielectric resonators embedded in a low-permittivity matrix for microwave that can process light at gigahertz frequencies Tunable dielectrics for microwave communication Integrated passive components Nanotube based solar cells High frequency ultrasound for nondestruc- tive

  2. High performance systems

    SciTech Connect (OSTI)

    Vigil, M.B.

    1995-03-01

    This document provides a written compilation of the presentations and viewgraphs from the 1994 Conference on High Speed Computing given at the High Speed Computing Conference, {open_quotes}High Performance Systems,{close_quotes} held at Gleneden Beach, Oregon, on April 18 through 21, 1994.

  3. High Performance Computing in

    E-Print Network [OSTI]

    Stamatakis, Alexandros

    High Performance Computing in Bioinformatics Thomas Ludwig (t.ludwig@computer.org) Ruprecht PART I: High Performance Computing Thomas Ludwig PART II: HPC Computing in Bioinformatics Alexandros #12;© Thomas Ludwig, Alexandros Stamatakis, GCB'04 3 PART I High Performance Computing Introduction

  4. Data, exergy, and energy analysis of a vertical-bore, ground-source heat pump to for domestic water heating under simulated occupancy conditions

    SciTech Connect (OSTI)

    Ally, Moonis Raza; Munk, Jeffrey D; Baxter, Van D; Gehl, Anthony C

    2015-01-01

    Evidence is provided to support the view that greater than two-thirds of energy required to produce domestic hot water may be extracted from the ground which serves as renewable energy resource. The case refers to a 345 m2 research house located in Oak Ridge, Tennessee, 36.01 N 84.26 W in a mixed-humid climate with HDD of 2218 C-days (3993 F-days) and CDD of 723 C-days (1301 F-days). The house is operated under simulated occupancy conditions in which the hot water use protocol is based on the Building America Research Benchmark Definition (Hendron 2008; Hendron and Engebrecht 2010) which captures the water consumption lifestyles of the average family in the United States. The 5.275 (1.5-ton) water-to-water ground source heat pump (WW-GSHP) shared the same vertical bore with a 7.56 KW water-to-air ground source heat pump for space conditioning the same house. Energy and exergy analysis of data collected continuously over a twelve month period provide performance metrics and sources of inherent systemic inefficiencies. Data and analyses are vital to better understand how WW-GSHPs may be further improved to enable the ground to be used as a renewable energy resource.

  5. High-performance combinatorial algorithms

    E-Print Network [OSTI]

    Pinar, Ali

    2003-01-01

    mathematics, and high performance computing. The numericalalgorithms on high performance computing platforms.algorithms on high performance computing platforms, which

  6. The effect of sociocultural factors on the quality of relations of the United States with Hispaniola: analysis of the American military occupation of Haiti and the Dominican Republic (1915-1934) 

    E-Print Network [OSTI]

    Alvarez, Fausto B.

    1988-01-01

    with Hispaniola reveals a strong emphasis on economic and strategic interests (see, for example, Langley, 1983' Wiarda and Kryzanek, 1982; Langley, 1982; Lowenthal, 1972, 1969; Knight, 1970). Therefore, the sociological significance of this study... with the role of social and cultural factors involved in the application of this policy. Melvin Knight, an American historian who had first-hand acquaintance with and who wrote about the military occupation of Hispaniola, described this "dilemma" as follows...

  7. Side-by-Side Field Evaluation of Highly Insulating Windows in the PNNL Lab Homes

    SciTech Connect (OSTI)

    Widder, Sarah H.; Parker, Graham B.; Baechler, Michael C.; Bauman, Nathan N.

    2012-08-01

    To examine the energy, air leakage, and thermal performance of highly insulating windows, a field evaluation was undertaken in a matched pair of all-electric, factory-built “Lab Homes” located on the Pacific Northwest National Laboratory (PNNL) campus in Richland, Washington. The “baseline” Lab Home B was retrofitted with “standard” double-pane clear aluminum-frame slider windows and patio doors, while the “experimental” Lab Home A was retrofitted with Jeld-Wen® triple-pane vinyl-frame slider windows and patio doors with a U-factor of 0.2 and solar heat gain coefficient of 0.19. To assess the window, the building shell air leakage, energy use, and interior temperatures of each home were compared during the 2012 winter heating and summer cooling seasons. The measured energy savings in Lab Home B averaged 5,821 watt-hours per day (Wh/day) during the heating season and 6,518 Wh/day during the cooling season. The overall whole-house energy savings of Lab Home B compared to Lab Home A are 11.6% ± 1.53% for the heating season and 18.4 ± 2.06% for the cooling season for identical occupancy conditions with no window coverings deployed. Extrapolating these energy savings numbers based on typical average heating degree days and cooling degree days per year yields an estimated annual energy savings of 12.2%, or 1,784 kWh/yr. The data suggest that highly insulating windows are an effective energy-saving measure that should be considered for high-performance new homes and in existing retrofits. However, the cost effectiveness of the measure, as determined by the simple payback period, suggests that highly insulating window costs continue to make windows difficult to justify on a cost basis alone. Additional reductions in costs via improvements in manufacturing and/or market penetration that continue to drive down costs will make highly insulating windows much more viable as a cost-effective energy efficiency measure. This study also illustrates that highly insulating windows have important impacts on peak load, occupant comfort, and condensation potential, which are not captured in the energy savings calculation. More consistent and uniform interior temperature distributions suggest that highly insulated windows, as part of a high performance building envelope, may enable more centralized duct design and downsized HVAC systems. Shorter, more centralized duct systems and smaller HVAC systems to yield additional cost savings, making highly insulating windows more cost effective as part of a package of new construction or retrofit measures which achieve significant reductions in home energy use.

  8. MEASURED SPACE CONDITIONING PERFORMANCE OFA VERTICAL-BORE GROUND SOURCE HEAT PUMP (GSHP) OVER TWELVE MONTHS UNDER SIMULATED OCCUPANCY LOADS

    SciTech Connect (OSTI)

    Ally, Moonis Raza [ORNL; Munk, Jeffrey D [ORNL; Baxter, Van D [ORNL; Gehl, Anthony C [ORNL

    2014-01-01

    This paper presents monthly performance metrics of a 7.56 kW (2.16 ton) GSHP serving the space conditioning loads of a 251m2 (2700ft2) residential home with a phase change material in its envelope, and a single vertical-bore 94.5m (310 ft) ground loop. The same ground loop also serviced a ground source heat pump water heater. Envelope characteristics are discussed briefly in the context of reducing thermal losses. Data on entering water temperatures, energy extracted from the ground, energy delivered/removed, compressor electricity use, COP, GSHP run times (low and high compressor stages), and the impact of fan and pump energy consumption on efficiency are presented for each month. Both practical as well as research and development issues are discussed. The findings suggest that GSHPs represent a practical technology option to reduce source energy reduction and greenhouse emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 target of generating over 25% of heat consumed in the EU from renewable energy.

  9. High power, high beam quality regenerative amplifier

    DOE Patents [OSTI]

    Hackel, Lloyd A. (Livermore, CA); Dane, Clifford B. (Livermore, CA)

    1993-01-01

    A regenerative laser amplifier system generates high peak power and high energy per pulse output beams enabling generation of X-rays used in X-ray lithography for manufacturing integrated circuits. The laser amplifier includes a ring shaped optical path with a limited number of components including a polarizer, a passive 90 degree phase rotator, a plurality of mirrors, a relay telescope, and a gain medium, the components being placed close to the image plane of the relay telescope to reduce diffraction or phase perturbations in order to limit high peak intensity spiking. In the ring, the beam makes two passes through the gain medium for each transit of the optical path to increase the amplifier gain to loss ratio. A beam input into the ring makes two passes around the ring, is diverted into an SBS phase conjugator and proceeds out of the SBS phase conjugator back through the ring in an equal but opposite direction for two passes, further reducing phase perturbations. A master oscillator inputs the beam through an isolation cell (Faraday or Pockels) which transmits the beam into the ring without polarization rotation. The isolation cell rotates polarization only in beams proceeding out of the ring to direct the beams out of the amplifier. The diffraction limited quality of the input beam is preserved in the amplifier so that a high power output beam having nearly the same diffraction limited quality is produced.

  10. High power, high beam quality regenerative amplifier

    DOE Patents [OSTI]

    Hackel, L.A.; Dane, C.B.

    1993-08-24

    A regenerative laser amplifier system generates high peak power and high energy per pulse output beams enabling generation of X-rays used in X-ray lithography for manufacturing integrated circuits. The laser amplifier includes a ring shaped optical path with a limited number of components including a polarizer, a passive 90 degree phase rotator, a plurality of mirrors, a relay telescope, and a gain medium, the components being placed close to the image plane of the relay telescope to reduce diffraction or phase perturbations in order to limit high peak intensity spiking. In the ring, the beam makes two passes through the gain medium for each transit of the optical path to increase the amplifier gain to loss ratio. A beam input into the ring makes two passes around the ring, is diverted into an SBS phase conjugator and proceeds out of the SBS phase conjugator back through the ring in an equal but opposite direction for two passes, further reducing phase perturbations. A master oscillator inputs the beam through an isolation cell (Faraday or Pockels) which transmits the beam into the ring without polarization rotation. The isolation cell rotates polarization only in beams proceeding out of the ring to direct the beams out of the amplifier. The diffraction limited quality of the input beam is preserved in the amplifier so that a high power output beam having nearly the same diffraction limited quality is produced.

  11. Relevance of supramolecular interactions, texture and lattice occupancy in the designer iron(II) spin crossover complexes

    SciTech Connect (OSTI)

    Naik, Anil D. [Unite de Chimie des Materiaux Inorganiques et Organiques, Departement de Chimie, Universite Catholique de Louvain, Place L. Pasteur 1, 1348 Louvain-la-Neuve (Belgium); Tinant, Bernard [Unite de Chimie Structurale et des Mecanismes Reactionnels, Departement de Chimie, Universite Catholique de Louvain, Place L. Pasteur 1, 1348 Louvain-la-Neuve (Belgium); Muffler, Kai; Wolny, Juliusz A.; Schuenemann, Volker [Technische Universitaet Kaiserslautern, Fachbereich Physik, Erwin-Schroedinger-Str. 56, 67663 Kaiserslautern (Germany); Garcia, Yann, E-mail: yann.garcia@uclouvain.b [Unite de Chimie des Materiaux Inorganiques et Organiques, Departement de Chimie, Universite Catholique de Louvain, Place L. Pasteur 1, 1348 Louvain-la-Neuve (Belgium)

    2009-06-15

    New Fe{sup II} complexes of formula [Fe(3-Br-phen){sub 2}(NCS){sub 2}].Solvent (Solvent=0.5 CH{sub 3}OH (1), 2 CH{sub 2}Cl{sub 2} (2), desolvation of 2 (3), 0.5 CH{sub 3}COCH{sub 3} (4) and 0 (5)) have been synthesized. {sup 57}Fe Moessbauer and magnetic investigation reveal unique features atypical of classic [Fe(phen){sub 2}(NCS){sub 2}] polymorphs. Complex 1, prepared by precipitation in MeOH, undergoes upon cooling below room temperature an incomplete and gradual thermally induced spin conversion, while 4 prepared by an extraction method remains mostly in the low-spin state. The non solvated compounds 3 and 5, display a more abrupt spin crossover on cooling around T{sub 1/2}=175 K and T{sub 1/2}=198 K, respectively. Defects/soft lattice inclusion due to different methods of material synthesis, extent of aging, reaction medium and associated solvent molecules have enormous influence on the particle size and magnetic properties of these complexes. Scanning electron micrographs helps to establish a logical relationship among methods employed for synthesis, texture of materials and their effect on magnetic properties. The crystal structure of 2 determined in the monoclinic space group P2/c (100 K) reveals a mononuclear complex consisting of a distorted FeN{sub 6} octahedron in the low-spin state, constructed from two 3-bromo-1, 10-phenanthroline and two isothiocyanato anions in cis position. Intermolecular interactions between mononuclear units of the S...Br, S...C(H) and pi-pi type afford a 2D supramolecular network. DFT calculations for the single molecule 2 reveals an energy difference between high-spin and low-spin isomers of 7 kJ/mol suggesting a slight destabilization of the low-spin state compared to [Fe(phen){sub 2}(NCS){sub 2}]. Normal co-ordinate analysis was also carried out for 3 and compared with experimental temperature dependent Raman spectra for 5. - Graphical abstract: New Fe{sup II} complexes of formula [Fe(3-Br-phen){sub 2}(NCS){sub 2}].Solvent have been synthesized by precipitation (1) and extraction (4) methods. {sup 57}Fe Moessbauer and magnetic investigation reveal unique features atypical of classic [Fe(phen){sub 2}(NCS){sub 2}] polymorphs. Complex 1, undergoes upon cooling below room temperature an incomplete and gradual thermally induced spin conversion, while 4 remains mostly in the low-spin state. Role of supramolecular interactions, particles size, lattice solvents have profound influence on magnetic properties.

  12. Highly directional thermal emitter

    DOE Patents [OSTI]

    Ribaudo, Troy; Shaner, Eric A; Davids, Paul; Peters, David W

    2015-03-24

    A highly directional thermal emitter device comprises a two-dimensional periodic array of heavily doped semiconductor structures on a surface of a substrate. The array provides a highly directional thermal emission at a peak wavelength between 3 and 15 microns when the array is heated. For example, highly doped silicon (HDSi) with a plasma frequency in the mid-wave infrared was used to fabricate nearly perfect absorbing two-dimensional gratings structures that function as highly directional thermal radiators. The absorption and emission characteristics of the HDSi devices possessed a high degree of angular dependence for infrared absorption in the 10-12 micron range, while maintaining high reflectivity of solar radiation (.about.64%) at large incidence angles.

  13. High voltage coaxial switch

    DOE Patents [OSTI]

    Rink, John P. (Los Alamos, NM)

    1983-07-19

    A coaxial high voltage, high current switch having a solid cylindrical cold cathode coaxially surrounded by a thin hollow cylindrical inner electrode and a larger hollow cylindrical outer electrode. A high voltage trigger between the cathode and the inner electrode causes electrons to be emitted from the cathode and flow to the inner electrode preferably through a vacuum. Some of the electrons penetrate the inner electrode and cause a volumetric discharge in the gas (which may be merely air) between the inner and outer electrodes. The discharge provides a low impedance path between a high voltage charge placed on the outer electrode and a load (which may be a high power laser) coupled to the inner electrode. For high repetition rate the gas between the inner and outer electrodes may be continuously exchanged or refreshed under pressure.

  14. High voltage coaxial switch

    DOE Patents [OSTI]

    Rink, J.P.

    1983-07-19

    A coaxial high voltage, high current switch having a solid cylindrical cold cathode coaxially surrounded by a thin hollow cylindrical inner electrode and a larger hollow cylindrical outer electrode. A high voltage trigger between the cathode and the inner electrode causes electrons to be emitted from the cathode and flow to the inner electrode preferably through a vacuum. Some of the electrons penetrate the inner electrode and cause a volumetric discharge in the gas (which may be merely air) between the inner and outer electrodes. The discharge provides a low impedance path between a high voltage charge placed on the outer electrode and a load (which may be a high power laser) coupled to the inner electrode. For high repetition rate the gas between the inner and outer electrodes may be continuously exchanged or refreshed under pressure. 3 figs.

  15. High pressure and high temperature apparatus

    DOE Patents [OSTI]

    Voronov, Oleg A.

    2005-09-13

    A design for high pressure/high temperature apparatus and reaction cell to achieve .about.30 GPa pressure in .about.1 cm volume and .about.100 GPa pressure in .about.1 mm volumes and 20-5000.degree. C. temperatures in a static regime. The device includes profiled anvils (28) action on a reaction cell (14, 16) containing the material (26) to be processed. The reaction cell includes a heater (18) surrounded by insulating layers and screens. Surrounding the anvils are cylindrical inserts and supporting rings (30-48) whose hardness increases towards the reaction cell. These volumes may be increased considerably if applications require it, making use of presses that have larger loading force capability, larger frames and using larger anvils.

  16. High output lamp with high brightness

    DOE Patents [OSTI]

    Kirkpatrick, Douglas A. (Great Falls, VA); Bass, Gary K. (Mt. Airy, MD); Copsey, Jesse F. (Germantown, MD); Garber, Jr., William E. (Poolesville, MD); Kwong, Vincent H. (Vancouver, CA); Levin, Izrail (Silver Spring, MD); MacLennan, Donald A. (Gaithersburg, MD); Roy, Robert J. (Frederick, MD); Steiner, Paul E. (Olney, MD); Tsai, Peter (Olney, MD); Turner, Brian P. (Damascus, MD)

    2002-01-01

    An ultra bright, low wattage inductively coupled electrodeless aperture lamp is powered by a solid state RF source in the range of several tens to several hundreds of watts at various frequencies in the range of 400 to 900 MHz. Numerous novel lamp circuits and components are disclosed including a wedding ring shaped coil having one axial and one radial lead, a high accuracy capacitor stack, a high thermal conductivity aperture cup and various other aperture bulb configurations, a coaxial capacitor arrangement, and an integrated coil and capacitor assembly. Numerous novel RF circuits are also disclosed including a high power oscillator circuit with reduced complexity resonant pole configuration, parallel RF power FET transistors with soft gate switching, a continuously variable frequency tuning circuit, a six port directional coupler, an impedance switching RF source, and an RF source with controlled frequency-load characteristics. Numerous novel RF control methods are disclosed including controlled adjustment of the operating frequency to find a resonant frequency and reduce reflected RF power, controlled switching of an impedance switched lamp system, active power control and active gate bias control.

  17. High Energy Physics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Large Scale Production Computing and Storage Requirements for High Energy Physics: Target 2017 HEPlogo.jpg The NERSC Program Requirements Review "Large Scale Computing and Storage...

  18. High Energy Physics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Scientific Computing Research Basic Energy Sciences Biological and Environmental Research Fusion Energy Sciences High Energy Physics Nuclear Physics Advanced Scientific Computing...

  19. Risk Factors in Heating, Ventilating, and Air-Conditioning Systemsfor Occupant Symptoms in U.S. Office Buildings: the EPA BASE Study

    SciTech Connect (OSTI)

    Mendell, M.J.; Lei-Gomez, Q.; Mirer, A.; Seppanen, O.; Brunner, G.

    2006-10-01

    Nonspecific building-related symptoms among occupants of modern office buildings worldwide are common and may be associated with important reductions in work performance, but their etiology remains uncertain. Characteristics of heating, ventilating, and air-conditioning (HVAC) systems in office buildings that increase risk of indoor contaminants or reduce effectiveness of ventilation may cause adverse exposures and subsequent increase in these symptoms among occupants. We analyzed data collected by the U.S. EPA from a representative sample of 100 large U.S. office buildings--the Building Assessment and Survey Evaluation (BASE) study--using multivariate logistic regression models with generalized estimating equations adjusted for potential personal and building confounders. We estimated odds ratios (ORs) and 95% confidence intervals (CIs) for associations between seven building-related symptom outcomes and selected HVAC system characteristics. Among factors of HVAC design or configuration: Outdoor air intakes less than 60 m above the ground were associated with approximately doubled odds of most symptoms assessed. Sealed (non-operable) windows were associated with increases in skin and eye symptoms (ORs= 1.9, 1.3, respectively). Outdoor air intake without an intake fan was associated with an increase in eye symptoms (OR=1.7). Local cooling coils were associated with increased headache (OR=1.5). Among factors of HVAC condition, maintenance, or operation: the presence of humidification systems in good condition was associated with an increase in headache (OR=1.4), whereas the presence of humidification systems in poor condition was associated with increases in fatigue/difficulty concentrating, as well as upper respiratory symptoms (ORs=1.8, 1.5). No regularly scheduled inspections for HVAC components was associated with increased eye symptoms, cough and upper respiratory symptoms (ORs=2.2, 1.6, 1.5). Less frequent cleaning of cooling coils or drip pans was associated with increased headache (OR=1.6). Fair or poor condition of duct liner was associated with increased upper respiratory symptoms (OR=1.4). Most of the many potential risk factors assessed here had not been investigated previously, and associations found with single symptoms may have been by chance, including several associations that were the reverse of expected. Risk factors newly identified in these analyses that deserve attention include outdoor air intakes less than 60 m above the ground, lack of operable windows, poorly maintained humidification systems, and lack of scheduled inspection for HVAC systems. Infrequent cleaning of cooling coils and drain pans were associated with increases in several symptoms in these as well as prior analyses of BASE data. Replication of these findings is needed, using more objective measurements of both exposure and health response. Confirmation of the specific HVAC factors responsible for increased symptoms in buildings, and development of prevention strategies could have major public health and economic benefits worldwide.

  20. Association of genetic polymorphisms in GADD45A, MDM2, and p14{sup ARF} with the risk of chronic benzene poisoning in a Chinese occupational population

    SciTech Connect (OSTI)

    Sun Pin; Zhang Zhongbin; Wan Junxiang; Zhao Naiqing; Jin Xipeng; Xia Zhaolin

    2009-10-01

    Benzene reactive metabolites can lead to DNA damage and trigger the p53-dependent defense responses to maintain genomic stability. We hypothesized that the p53-dependent genes may play a role in the development of chronic benzene poisoning (CBP). In a case-control study of 303 patients with benzene poisoning and 295 workers occupationally exposed to benzene in south China, we investigated associations between the risk of CBP and polymorphisms in three p53-dependent genes. Potential interactions of these polymorphisms with lifestyle factors were also explored. We found p14{sup ARF} rs3731245 polymorphism was associated with risk of CBP (P = 0.014). Compared with those carrying the GG genotype, individuals carrying p14{sup ARF} rs3731245 GA+AA genotypes had a reduced risk of CBP ([adjusted odds ratio (OR{sub adj}) = 0.57, 95%CI = 0.36-0.89]. Further analysis showed p14{sup ARF} TGA/TAG diplotype was associated with an increased risk of CBP (P = 0.0006), whereas p14{sup ARF} TGG/TAA diplotype was associated with a decreased risk of CBP (P = 0.0000001). In addition, we found individuals carrying both MDM2 Del1518 WW genotype and p14{sup ARF} rs3731245 GA+AA genotypes had a lower risk of CBP (OR{sub adj} = 0.25; 95%CI = 0.10-0.62; P = 0.003). Although these results require confirmation and extension, our findings suggest that genetic polymorphisms in p14{sup ARF} may have an impact on the risk of CBP in the study population.

  1. Site occupancy and cation binding states in reduced polycrystalline Sr{sub x}Ba{sub 1?x}Nb{sub 2}O{sub 6}

    SciTech Connect (OSTI)

    Dandeneau, Christopher S., E-mail: dandec@u.washington.edu; Yang, YiHsun; Ohuchi, Fumio S. [Department of Materials Science and Engineering, University of Washington, Seattle, Washington 98195 (United States)] [Department of Materials Science and Engineering, University of Washington, Seattle, Washington 98195 (United States); Krueger, Benjamin W.; Olmstead, Marjorie A. [Department of Physics, University of Washington, Seattle, Washington 98195 (United States)] [Department of Physics, University of Washington, Seattle, Washington 98195 (United States); Bordia, Rajendra K. [Department of Materials Science and Engineering, Clemson University, Clemson, South Carolina 29634 (United States)] [Department of Materials Science and Engineering, Clemson University, Clemson, South Carolina 29634 (United States)

    2014-03-10

    Site occupancy and cation binding states in the proposed thermoelectric n-type oxide Sr{sub x}Ba{sub 1?x}Nb{sub 2}O{sub 6} (SBN100x) were investigated using X-ray photoelectron spectroscopy (XPS). Sr 3d XPS spectra from unreduced polycrystalline SBN100x with various compositions contained two distinct spin-orbit doublets corresponding to Sr occupying either A1 or A2 positions in the SBN lattice; the higher binding energy state was associated with Sr ions at A2 sites, presumably due to their increased coordination over Sr at A1 sites. To gain insight into optimizing the thermoelectric properties of reduced SBN, sintered SBN50 specimens were reduced in Ar/H{sub 2} or N{sub 2}/H{sub 2} ambient. A decrease in the average Nb valence was observed in Nb 3d photoemission through the growth of low-binding energy components after reduction in either environment; evidence of surface NbN formation was apparent with longer reducing times in N{sub 2}/H{sub 2}. Both the single-component Ba 3d emission and the A2 component of the Sr 3d spectra show shifting to lower binding energy as the reduction time is increased, supporting the hypothesis of preferential oxygen vacancy formation adjacent to A2 sites. X-ray diffraction patterns revealed the formation of NbO{sub 2} in both reducing environments; in the case of extended reduction in N{sub 2}/H{sub 2}, NbO{sub 2} is gradually converted to NbN phases. Given the known properties of metallic NbN and semiconducting NbO{sub 2}, the findings obtained here may be used to maximize the thermoelectric performance of SBN via the fabrication of composite structures containing both NbO{sub 2} and NbN.

  2. Contaminants in Buildings and Occupied Spaces as Risk Factors forOccupant Symptoms in U.S. Office Buildings: Findings from the U.S. EPABASE Study

    SciTech Connect (OSTI)

    Mendell, M.J.; Mirer, A.; Lei-Gomez, Q.

    2007-08-01

    Nonspecific building-related symptoms among occupants of modern office buildings worldwide are common and may be associated with important reductions in work performance, but their etiology remains uncertain. Most reported research into environmental risk factors for these symptoms has focused on ventilation system-related factors, dampness, and particle removal through filtration and cleaning, with relatively few studies of other potential sources of indoor contaminants. We analyzed data collected by the U.S. Environmental Protection Agency (EPA) from a representative sample of 100 large U.S. office buildings--the Building Assessment and Survey Evaluation (BASE) study--using multivariate-adjusted logistic regression models with generalized estimating equations. We estimated odds ratios (ORs) and 95% confidence intervals (CIs) for associations between seven building-related symptom outcomes and a diverse set of potential indoor and outdoor sources for indoor pollutants. Although most of the investigated risk factors showed no apparent association with building-related symptoms, some interesting associations resulted. Increased prevalence of symptoms was associated with carpets older than one year (lower respiratory symptoms), non-carpeted floors (upper and lower respiratory symptoms), older furniture (eye and skin symptoms), infrequent vacuuming (upper respiratory, eye, and skin symptoms and headache), and masonry exterior walls (cough, eye symptoms, and fatigue/concentration difficulty). For the many potential risk factors assessed, almost none had been investigated previously, and many associations found here may have been by chance. Additional confirmatory research focused on risk factors initially identified here is needed, using more objective measures of health outcomes and risk factors or exposures.

  3. High coking value pitch

    SciTech Connect (OSTI)

    Miller, Douglas J.; Chang, Ching-Feng; Lewis, Irwin C.; Lewis, Richard T.

    2014-06-10

    A high coking value pitch prepared from coal tar distillate and has a low softening point and a high carbon value while containing substantially no quinoline insolubles is disclosed. The pitch can be used as an impregnant or binder for producing carbon and graphite articles.

  4. Development of a High-Efficiency Zonal Thermoelectric HVAC System for Automotive Applications

    Broader source: Energy.gov [DOE]

    Identify a technical and business approach to accelerate the deployment of light-duty automotive TE HVAC technology, maintain occupant comfort, and improve energy efficiency.

  5. Many classroom lighting systems provide mediocre lighting quality and have high

    E-Print Network [OSTI]

    , superintendents, principals, architects, lighting designers, utility staff, and code officials can use information community and school officials about the system's availability. · Document system performance and occupant

  6. High power, high frequency, vacuum flange

    DOE Patents [OSTI]

    Felker, B.; McDaniel, M.R.

    1993-03-23

    An improved waveguide flange is disclosed for high power operation that helps prevent arcs from being initiated at the junctions between waveguide sections. The flanges at the end of the waveguide sections have counter bores surrounding the waveguide tubes. When the sections are bolted together the counter bores form a groove that holds a fully annealed copper gasket. Each counterbore has a beveled step that is specially configured to insure the gasket forms a metal-to-metal vacuum seal without gaps or sharp edges. The resultant inner surface of the waveguide is smooth across the junctions between waveguide sections, and arcing is prevented.

  7. Response of High-Tc Superconductor Metamaterials to High Intensity...

    Office of Scientific and Technical Information (OSTI)

    Conference: Response of High-Tc Superconductor Metamaterials to High Intensity THz Radiation Citation Details In-Document Search Title: Response of High-Tc Superconductor...

  8. RECHARGEABLE HIGH-TEMPERATURE BATTERIES

    E-Print Network [OSTI]

    Cairns, Elton J.

    2014-01-01

    F. Eshman, High-Performance Batteries for Electric-VehicleS. Sudar, High Performance Batteries for Electric-VehicleHIGH-TEMPERATURE BATTERIES Elton J. Cairns January 1981 TWO-

  9. Sandia Energy - High Performance Computing

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    High Performance Computing Home Energy Research Advanced Scientific Computing Research (ASCR) High Performance Computing High Performance Computingcwdd2015-03-18T21:41:24+00:00...

  10. Sandia Energy - High Pressure Chemistry

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    High Pressure Chemistry Home Transportation Energy Predictive Simulation of Engines Combustion Chemistry Combustion Kinetics High Pressure Chemistry High Pressure ChemistryAshley...

  11. High pressure counterflow CHF.

    E-Print Network [OSTI]

    Walkush, Joseph Patrick

    1975-01-01

    This is a report of the experimental results of a program in countercurrent flow critical heat flux. These experiments were performed with Freon 113 at 200 psia in order to model a high pressure water system. An internally ...

  12. High pressure furnace

    DOE Patents [OSTI]

    Morris, D.E.

    1993-09-14

    A high temperature high pressure furnace has a hybrid partially externally heated construction. A metallic vessel fabricated from an alloy having a composition of at least 45% nickel, 15% chrome, and 10% tungsten is utilized (the preferred alloy including 55% nickel, 22% chrome, 14% tungsten, 2% molybdenum, 3% iron (maximum) and 5% cobalt (maximum)). The disclosed alloy is fabricated into 11/4 or 2 inch, 32 mm or 50 mm bar stock and has a length of about 22 inches, 56 cm. This bar stock has an aperture formed therein to define a closed high temperature, high pressure oxygen chamber. The opposite and closed end of the vessel is provided with a small blind aperture into which a thermocouple can be inserted. The closed end of the vessel is inserted into an oven, preferably heated by standard nickel chrome electrical elements and having a heavily insulated exterior. 19 figures.

  13. Using High Performance Libraries

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    by the QPI (Quick Path Interconnect) links). Using the QPI to simulate the slow memory (DDR memory) while using the memory on the near socket as the high bandwidth memory (MCDRAM...

  14. High pressure furnace

    DOE Patents [OSTI]

    Morris, Donald E. (Kensington, CA)

    1993-01-01

    A high temperature high pressure furnace has a hybrid partially externally heated construction. A metallic vessel fabricated from an alloy having a composition of at least 45% nickel, 15% chrome, and 10% tungsten is utilized (the preferred alloy including 55% nickel, 22% chrome, 14% tungsten, 2% molybdenum, 3% iron (maximum) and 5% cobalt (maximum). The disclosed alloy is fabricated into 11/4 or 2 inch, 32 mm or 50 mm bar stock and has a length of about 22 inches, 56 cm. This bar stock has an aperture formed therein to define a closed high temperature, high pressure oxygen chamber. The opposite and closed end of the vessel is provided with a small blind aperture into which a thermocouple can be inserted. The closed end of the vessel is inserted into an oven, preferably heated by standard nickel chrome electrical elements and having a heavily insulated exterior.

  15. High-Temperature Superconductivity

    ScienceCinema (OSTI)

    Peter Johnson

    2010-01-08

    Like astronomers tweaking images to gain a more detailed glimpse of distant stars, physicists at Brookhaven National Laboratory have found ways to sharpen images of the energy spectra in high-temperature superconductors ? materials that carry electrical c

  16. High pressure oxygen furnace

    DOE Patents [OSTI]

    Morris, Donald E. (Kensington, CA)

    1992-01-01

    A high temperature high pressure oxygen furnace having a hybrid partially externally heated construction is disclosed. A metallic bar fabricated from an alloy having a composition of at least 45% nickel, 15% chrome, and 10% tungsten is utilized (the preferred alloy including 55% nickel, 22% chrome, 14% tungsten, 2% molybdenum, 3% iron (maximum) and 5% cobalt (maximum). The disclosed alloy is fabricated into 11/4 inch bar stock and has a length of about 17 inches. This bar stock is gun drilled for over 16 inches of its length with 0.400 inch aperture to define a closed high temperature, high pressure oxygen chamber. The opposite and closed end of the bar is provided with a small support aperture into which both a support and a thermocouple can be inserted. The closed end of the gun drilled bar is inserted into an oven, preferably heated by standard nickel chrome electrical elements and having a heavily insulated exterior.

  17. High pressure oxygen furnace

    DOE Patents [OSTI]

    Morris, D.E.

    1992-07-14

    A high temperature high pressure oxygen furnace having a hybrid partially externally heated construction is disclosed. A metallic bar fabricated from an alloy having a composition of at least 45% nickel, 15% chrome, and 10% tungsten is utilized, the preferred alloy including 55% nickel, 22% chrome, 14% tungsten, 2% molybdenum, 3% iron (maximum) and 5% cobalt (maximum). The disclosed alloy is fabricated into 11/4 inch bar stock and has a length of about 17 inches. This bar stock is gun drilled for over 16 inches of its length with 0.400 inch aperture to define a closed high temperature, high pressure oxygen chamber. The opposite and closed end of the bar is provided with a small support aperture into which both a support and a thermocouple can be inserted. The closed end of the gun drilled bar is inserted into an oven, preferably heated by standard nickel chrome electrical elements and having a heavily insulated exterior. 5 figs.

  18. High-Speed Photography

    SciTech Connect (OSTI)

    Paisley, D.L.; Schelev, M.Y.

    1998-08-01

    The applications of high-speed photography to a diverse set of subjects including inertial confinement fusion, laser surgical procedures, communications, automotive airbags, lightning etc. are briefly discussed. (AIP) {copyright} {ital 1998 Society of Photo-Optical Instrumentation Engineers.}

  19. High Performance Sustainable Building

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2011-11-09

    This Guide provides approaches for implementing the High Performance Sustainable Building (HPSB) requirements of DOE Order 413.3B, Program and Project Management for the Acquisition of Capital Assets. Supersedes DOE G 413.3-6.

  20. Creating high performance enterprises

    E-Print Network [OSTI]

    Stanke, Alexis K. (Alexis Kristen), 1977-

    2006-01-01

    How do enterprises successfully conceive, design, deliver, and operate large-scale, engineered systems? These large-scale projects often involve high complexity, significant technical challenges, a large number of diverse ...

  1. A Post-Occupancy Monitored Evaluation of the Dimmable Lighting, Automated Shading, and Underfloor Air Distribution System in The New York Times Building

    E-Print Network [OSTI]

    2013-01-01

    for buildings with high churn rates where speed and cost isfor space reconfiguration or churn is included, payback time

  2. High-temperature sensor

    DOE Patents [OSTI]

    Not Available

    1981-01-29

    A high temperature sensor is described which includes a pair of electrical conductors separated by a mass of electrical insulating material. The insulating material has a measurable resistivity within the sensor that changes in relation to the temperature of the insulating material within a high temperature range (1000 to 2000/sup 0/K). When required, the sensor can be encased within a ceramic protective coating.

  3. High efficiency incandescent lighting

    DOE Patents [OSTI]

    Bermel, Peter; Ilic, Ognjen; Chan, Walker R.; Musabeyoglu, Ahmet; Cukierman, Aviv Ruben; Harradon, Michael Robert; Celanovic, Ivan; Soljacic, Marin

    2014-09-02

    Incandescent lighting structure. The structure includes a thermal emitter that can, but does not have to, include a first photonic crystal on its surface to tailor thermal emission coupled to, in a high-view-factor geometry, a second photonic filter selected to reflect infrared radiation back to the emitter while passing visible light. This structure is highly efficient as compared to standard incandescent light bulbs.

  4. High conductivity composite metal

    DOE Patents [OSTI]

    Zhou, R.; Smith, J.L.; Embury, J.D.

    1998-01-06

    Electrical conductors and methods of producing them are disclosed, where the conductors possess both high strength and high conductivity. Conductors are comprised of carbon steel and a material chosen from a group consisting of copper, nickel, silver, and gold. Diffusion barriers are placed between these two materials. The components of a conductor are assembled and then the assembly is subjected to heat treating and mechanical deformation steps. 10 figs.

  5. High temperature pressure gauge

    DOE Patents [OSTI]

    Echtler, J. Paul (Pittsburgh, PA); Scandrol, Roy O. (Library, PA)

    1981-01-01

    A high temperature pressure gauge comprising a pressure gauge positioned in fluid communication with one end of a conduit which has a diaphragm mounted in its other end. The conduit is filled with a low melting metal alloy above the diaphragm for a portion of its length with a high temperature fluid being positioned in the remaining length of the conduit and in the pressure gauge.

  6. High Risk Plan

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum12,ExecutiveFinancing ProgramsDepartment of¡High HIGH PERFORMANCE

  7. High Burnup Effects Program

    SciTech Connect (OSTI)

    Barner, J.O.; Cunningham, M.E.; Freshley, M.D.; Lanning, D.D.

    1990-04-01

    This is the final report of the High Burnup Effects Program (HBEP). It has been prepared to present a summary, with conclusions, of the HBEP. The HBEP was an international, group-sponsored research program managed by Battelle, Pacific Northwest Laboratories (BNW). The principal objective of the HBEP was to obtain well-characterized data related to fission gas release (FGR) for light water reactor (LWR) fuel irradiated to high burnup levels. The HBEP was organized into three tasks as follows: Task 1 -- high burnup effects evaluations; Task 2 -- fission gas sampling; and Task 3 -- parameter effects study. During the course of the HBEP, a program that extended over 10 years, 82 fuel rods from a variety of sources were characterized, irradiated, and then examined in detail after irradiation. The study of fission gas release at high burnup levels was the principal objective of the program and it may be concluded that no significant enhancement of fission gas release at high burnup levels was observed for the examined rods. The rim effect, an as yet unquantified contributor to athermal fission gas release, was concluded to be the one truly high-burnup effect. Though burnup enhancement of fission gas release was observed to be low, a full understanding of the rim region and rim effect has not yet emerged and this may be a potential area of further research. 25 refs., 23 figs., 4 tabs.

  8. Revisit of Energy Use and Technologies of High Performance Buildings

    SciTech Connect (OSTI)

    Li , Cheng; Hong , Tianzhen

    2014-03-30

    Energy consumed by buildings accounts for one third of the world?s total primary energy use. Associated with the conscious of energy savings in buildings, High Performance Buildings (HPBs) has surged across the world, with wide promotion and adoption of various performance rating and certification systems. It is valuable to look into the actual energy performance of HPBs and to understand their influencing factors. To shed some light on this topic, this paper conducted a series of portfolio analysis based on a database of 51 high performance office buildings across the world. Analyses showed that the actual site Energy Use Intensity (EUI) of the 51 buildings varied by a factor of up to 11, indicating a large scale of variation of the actual energy performance of the current HPBs. Further analysis of the correlation between EUI and climate elucidated ubiquitous phenomenon of EUI scatter throughout all climate zones, implying that the weather is not a decisive factor, although important, for the actual energy consumption of an individual building. On the building size via EUI, analysis disclosed that smaller buildings have a tendency to achieving lower energy use. Even so, the correlation is not absolute since some large buildings demonstrated low energy use while some small buildings performed opposite. Concerning the technologies, statistics indicated that the application of some technologies had correlations with some specific building size and climate characteristic. However, it was still hard to pinpoint a set of technologies which was directly correlative with a group of low EUI buildings. It is concluded that no a single factor essentially determines the actual energy performance of HPBs. To deliver energy-efficient buildings, an integrated design taking account of climate, technology, occupant behavior as well as operation and maintenance should be implemented.

  9. OCCUPATIONAL MEASURES AND AVERAGED SHAPE ...

    E-Print Network [OSTI]

    2015-01-19

    The aforementioned bounds extend previous bounds by Bright and Lee [7] from the .... of probability measures is characterized as follows (see Billingsley [9]). µk.

  10. Video occupant detection and classification

    DOE Patents [OSTI]

    Krumm, John C. (Albuquerque, NM)

    1999-01-01

    A system for determining when it is not safe to arm a vehicle airbag by storing representations of known situations as observed by a camera at a passenger seat; and comparing a representation of a camera output of the current situation to the stored representations to determine the known situation most closely represented by the current situation. In the preferred embodiment, the stored representations include the presence or absence of a person or infant seat in the front passenger seat of an automobile.

  11. Beryllium - HPMC Occupational Health Services

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Hanford in accordance with 10 CFR 850. This program is designed to provide professional services in support of Hanford workers. HPMC OMS is committed to the health, preventive...

  12. Ergonomics - HPMC Occupational Health Services

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Font Size Decrease Font Size AMHErgonomicsImages HPMC OMS provides ergonomic support services which include consultation, office and field ergonomic evaluation and education....

  13. Ergonomics - HPMC Occupational Health Services

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Health Education & Wellness > Downloads & Patient Materials > Ergonomics Health Education & Wellness Downloads & Patient Materials Ergonomics Fitness & Exercise Men's Health...

  14. Diabetes - HPMC Occupational Health Services

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Cold and Flu Prevention Hand Washing Healthy Sleep Heat Stress Radon Signs of a Heart Attack Signs of a Stroke Coping with Stress & Change Skin Cancer Awareness Choose My...

  15. Radon - HPMC Occupational Health Services

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Cold and Flu Prevention Hand Washing Healthy Sleep Heat Stress Radon Signs of a Heart Attack Signs of a Stroke Coping with Stress & Change Skin Cancer Awareness Choose My...

  16. Occupational Medicine | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room NewsInformationJesseworkSURVEY UNIVERSEHowScientific andComplex Oak RidgeObservation

  17. Thermoelectrics Partnership: High Performance Thermoelectric...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    High Performance Thermoelectric Waste Heat Recovery System Based on Zintl Phase Materials with Embedded Nanoparticles Thermoelectrics Partnership: High Performance Thermoelectric...

  18. High surface area, high permeability carbon monoliths

    SciTech Connect (OSTI)

    Lagasse, R.R.; Schroeder, J.L. [Sandia National Labs., Albuquerque, NM (United States). Organic Materials Processing Dept.

    1994-12-31

    The goal of this work is to prepare carbon monoliths having precisely tailored pore size distribution. Prior studies have demonstrated that poly(acrylonitrile) can be processed into a precursor having tailored macropore structure. Since the macropores were preserved during pyrolysis, this synthetic process provided a route to porous carbon having macropores with size =0.1 to 10{mu}m. No micropores of size <2 nm could be detected in the carbon, however, by nitrogen adsorption. In the present work, the authors have processed a different polymer, poly(vinylidene chloride) into a macroporous precursor, Pyrolysis produced carbon monoliths having macropores derived from the polymer precursor as well as extensive microporosity produced during the pyrolysis of the polymer. One of these carbons had BET surface area of 1,050 m{sup 2}/g and about 1.2 cc/g total pore volume, with about 1/3 of the total pore volume in micropores and the remainder in 1{mu}m macropores. No mesopores in the intermediate size range could be detected by nitrogen adsorption. Carbon materials having high surface area as well as micron size pores have potential applications as electrodes for double layer supercapacitors containing liquid electrolyte, or as efficient media for performing chemical separations.

  19. High pressure melt ejection

    SciTech Connect (OSTI)

    Tarbell, W.W.; Brockmann, J.E.; Pilch, M.

    1983-01-01

    Recent probabilistic risk assessments have identified the potential for reactor pressure vessel failure while the reactor coolant system is at elevated pressure. The analyses postulate that the blowdown of steam and hydrogen into the reactor cavity will cause the core material to be swept from the cavity region into the containment building. The High Pressure Melt Streaming (HIPS) program is an experimental study of the high pressure ejection of molten material and subsequent interactions within a concrete cavity. The program focuses on using prototypic system conditions and scaled models of reactor geometries to accurately simulate the ex-vessel processes during high-pressure accident sequences. Scaling analyses of the experiment show that the criteria established for core debris removal from the cavity are met or exceeded. Tests are performed at two scales, representing 1/10th and 1/20th linear reproductions of the Zion reactor plant. Results of the 1/20th scale tests are presented.

  20. High resolution data acquisition

    DOE Patents [OSTI]

    Thornton, G.W.; Fuller, K.R.

    1993-04-06

    A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock, pulse train, and analog circuitry for generating a triangular wave synchronously with the pulse train (as seen in diagram on patent). The triangular wave has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter counts the clock pulse train during the interval to form a gross event interval time. A computer then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.

  1. High Metallicity LGRB Hosts

    E-Print Network [OSTI]

    Graham, J F; Levesque, E M; Kewley, L J; Tanvir, N R; Levan, A J; Patel, S K; Misra, K; Huang, K -H; Reichart, D E; Nysewander, M; Schady, P

    2015-01-01

    We present our imaging and spectroscopic observations of the host galaxies of two dark long bursts with anomalously high metallicities, LGRB 051022 and LGRB 020819B, which in conjunction with another LGRB event with an optical afterglow comprise the three LGRBs with high metallicity host galaxies in the Graham & Fruchter (2013) sample. In Graham & Fruchter (2013), we showed that LGRBs exhibit a strong and apparently intrinsic preference for low metallicity environments (12+log(O/H) & redshift. This is surprising: even among a preselected sample of high metallicity LGRBs, were the metal aversion to remain in effect for these objects, we would expect their metallicity to still be lower than the typical metallicity for the galaxies at that luminosity and redshift. Therefore we deduce that it...

  2. High resolution data acquisition

    DOE Patents [OSTI]

    Thornton, Glenn W. (Los Alamos, NM); Fuller, Kenneth R. (Los Alamos, NM)

    1993-01-01

    A high resolution event interval timing system measures short time intervals such as occur in high energy physics or laser ranging. Timing is provided from a clock (38) pulse train (37) and analog circuitry (44) for generating a triangular wave (46) synchronously with the pulse train (37). The triangular wave (46) has an amplitude and slope functionally related to the time elapsed during each clock pulse in the train. A converter (18, 32) forms a first digital value of the amplitude and slope of the triangle wave at the start of the event interval and a second digital value of the amplitude and slope of the triangle wave at the end of the event interval. A counter (26) counts the clock pulse train (37) during the interval to form a gross event interval time. A computer (52) then combines the gross event interval time and the first and second digital values to output a high resolution value for the event interval.

  3. High-energy detector

    DOE Patents [OSTI]

    Bolotnikov, Aleksey E. (South Setauket, NY); Camarda, Giuseppe (Farmingville, NY); Cui, Yonggang (Upton, NY); James, Ralph B. (Ridge, NY)

    2011-11-22

    The preferred embodiments are directed to a high-energy detector that is electrically shielded using an anode, a cathode, and a conducting shield to substantially reduce or eliminate electrically unshielded area. The anode and the cathode are disposed at opposite ends of the detector and the conducting shield substantially surrounds at least a portion of the longitudinal surface of the detector. The conducting shield extends longitudinally to the anode end of the detector and substantially surrounds at least a portion of the detector. Signals read from one or more of the anode, cathode, and conducting shield can be used to determine the number of electrons that are liberated as a result of high-energy particles impinge on the detector. A correction technique can be implemented to correct for liberated electron that become trapped to improve the energy resolution of the high-energy detectors disclosed herein.

  4. High strength alloys

    DOE Patents [OSTI]

    Maziasz, Phillip James; Shingledecker, John Paul; Santella, Michael Leonard; Schneibel, Joachim Hugo; Sikka, Vinod Kumar; Vinegar, Harold J.; John, Randy Carl; Kim, Dong Sub

    2012-06-05

    High strength metal alloys are described herein. At least one composition of a metal alloy includes chromium, nickel, copper, manganese, silicon, niobium, tungsten and iron. System, methods, and heaters that include the high strength metal alloys are described herein. At least one heater system may include a canister at least partially made from material containing at least one of the metal alloys. At least one system for heating a subterranean formation may include a tublar that is at least partially made from a material containing at least one of the metal alloys.

  5. High strength alloys

    DOE Patents [OSTI]

    Maziasz, Phillip James [Oak Ridge, TN; Shingledecker, John Paul [Knoxville, TN; Santella, Michael Leonard [Knoxville, TN; Schneibel, Joachim Hugo [Knoxville, TN; Sikka, Vinod Kumar [Oak Ridge, TN; Vinegar, Harold J [Bellaire, TX; John, Randy Carl [Houston, TX; Kim, Dong Sub [Sugar Land, TX

    2010-08-31

    High strength metal alloys are described herein. At least one composition of a metal alloy includes chromium, nickel, copper, manganese, silicon, niobium, tungsten and iron. System, methods, and heaters that include the high strength metal alloys are described herein. At least one heater system may include a canister at least partially made from material containing at least one of the metal alloys. At least one system for heating a subterranean formation may include a tubular that is at least partially made from a material containing at least one of the metal alloys.

  6. Highly Effective Actions

    E-Print Network [OSTI]

    John H. Schwarz

    2013-11-22

    It is conjectured that the world-volume action of a probe D3-brane in an $AdS_5 \\times S^5$ background of type IIB superstring theory, with one unit of flux, can be reinterpreted as the exact effective action (or highly effective action) for U(2), ${\\cal N} = 4$ super Yang-Mills theory on the Coulomb branch. An analogous conjecture for $U(2)_k \\times U(2)_{-k} $ ABJM theory is also presented. The main evidence supporting these conjectures is that the brane actions have all of the expected symmetries and dualities. Highly effective actions have general coordinate invariance, even though they describe nongravitational theories.

  7. High-Tc Superconductor

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration would likeUniverse (JournalvivoHigh energy neutronHigh-Pressure MOF ResearchEnergyDonghui Lu,

  8. High-fidelity Modeling

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration would likeUniverse (JournalvivoHigh energy neutronHigh-Pressure MOFElectricityBiofuel

  9. High-speed

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration would likeUniverse (JournalvivoHigh energy neutronHigh-PressureLaboratoryspeed three-wave

  10. High-␤,

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration would likeUniverse (JournalvivoHigh energy neutronHigh-PressureLaboratoryspeed

  11. Concepts for High Availability in Scientific High-End Computing

    E-Print Network [OSTI]

    Engelmann, Christian

    Concepts for High Availability in Scientific High-End Computing Christian Engelmann 1,2 and Stephen 2 Department of Computer Science The University of Reading, Reading, UK High Availability and Stephen L. Scott, Oak Ridge National Laboratory Concepts for High Availability in Scientific High

  12. High Energy Photoproduction

    E-Print Network [OSTI]

    J. M. Butterworth; M. Wing

    2005-09-15

    The experimental and phenomenological status of high energy photoproduction is reviewed. Topics covered include the structure of the photon, production of jets, heavy flavours and prompt photons, rapidity gaps, energy flow and underlying events. The results are placed in the context of the current understanding of QCD, with particular application to present and future hadron and lepton colliders.

  13. High temperature storage battery

    SciTech Connect (OSTI)

    Sammells, A.F.

    1988-06-07

    A high temperature electrochemical cell is described comprising: a solid-state divalent cation conducting electrolyte; a positive electrode in contact with the electrolyte; a solid-state negative electrode contacting a divalent cation conducting molten salt mediating agent providing ionic mediation between the solid-state negative electrode and the solid-state electrolyte.

  14. High Power Cryogenic Targets

    SciTech Connect (OSTI)

    Gregory Smith

    2011-08-01

    The development of high power cryogenic targets for use in parity violating electron scattering has been a crucial ingredient in the success of those experiments. As we chase the precision frontier, the demands and requirements for these targets have grown accordingly. We discuss the state of the art, and describe recent developments and strategies in the design of the next generation of these targets.

  15. High Temperature ESP Monitoring

    Broader source: Energy.gov [DOE]

    The purpose of the High Temperature ESP Monitoring project is to develop a down-hole monitoring system to be used in wells with bottom hole temperature up to 300 °C for measuring motor temperature; pump discharge pressure; and formation temperature and pressure.

  16. High speed door assembly

    DOE Patents [OSTI]

    Shapiro, C.

    1993-04-27

    A high speed door assembly is described, comprising an actuator cylinder and piston rods, a pressure supply cylinder and fittings, an electrically detonated explosive bolt, a honeycomb structured door, a honeycomb structured decelerator, and a structural steel frame encasing the assembly to close over a 3 foot diameter opening within 50 milliseconds of actuation, to contain hazardous materials and vapors within a test fixture.

  17. High speed door assembly

    DOE Patents [OSTI]

    Shapiro, Carolyn (Idaho Falls, ID)

    1993-01-01

    A high speed door assembly, comprising an actuator cylinder and piston rods, a pressure supply cylinder and fittings, an electrically detonated explosive bolt, a honeycomb structured door, a honeycomb structured decelerator, and a structural steel frame encasing the assembly to close over a 3 foot diameter opening within 50 milliseconds of actuation, to contain hazardous materials and vapors within a test fixture.

  18. High expression Zymomonas promoters

    DOE Patents [OSTI]

    Viitanen, Paul V. (West Chester, PA); Tao, Luan (Havertown, PA); Zhang, Yuying (New Hope, PA); Caimi, Perry G. (Kennett Square, PA); McCole, Laura (East Fallowfield, PA): Zhang, Min (Lakewood, CO); Chou, Yat-Chen (Lakewood, CO); McCutchen, Carol M. (Wilmington, DE); Franden, Mary Ann (Centennial, CO)

    2011-08-02

    Identified are mutants of the promoter of the Z. mobilis glyceraldehyde-3-phosphate dehydrogenase gene, which direct improved expression levels of operably linked heterologous nucleic acids. These are high expression promoters useful for expression of chimeric genes in Zymomonas, Zymobacter, and other related bacteria.

  19. High Performance Sustainable Building

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2008-06-20

    The guide supports DOE O 413.3A and provides useful information on the incorporation of high performance sustainable building principles into building-related General Plant Projects and Institutional General Plant Projects at DOE sites. Canceled by DOE G 413.3-6A. Does not cancel other directives.

  20. CSTI high capacity power

    SciTech Connect (OSTI)

    Winter, J.M.

    1994-09-01

    The SP-100 program was established in 1983 by DOD, DOE, and NASA as a joint program to develop the technology necessary for space nuclear power systems for military and civil application. During FY86 and 87, the NASA SP-100 Advanced Technology Program was devised to maintain the momentum of promising technology advancement efforts started during Phase I of SP-100 and to strengthen, in key areas, the chances for successful development and growth capability of space nuclear reactor power systems for future space applications. In FY88, the Advanced Technology Program was incorporated into NASA`s new Civil Space Technology Initiative (CSTI). The CSTI Program was established to provide the foundation for technology development in automation and robotics, information, propulsion, and power. The CSTI High Capacity Power Program builds on the technology efforts of the SP-100 program, incorporates the previous NASA SP-100 Advanced Technology project, and provides a bridge to NASA Project Pathfinder. The elements of CSTI High Capacity Power development include Conversion Systems, Thermal Management, Power Management, System Diagnostics, and Environmental Interactions. Technology advancement in all areas, including materials, is required to assure the high reliability and 7 to 10 year lifetime demanded for future space nuclear power systems. The overall program will develop and demonstrate the technology base required to provide a wide range of modular power systems as well as allowing mission independence from solar and orbital attitude requirements. Several recent advancements in CSTI High Capacity power development will be discussed.

  1. High Selectivity Oxygen Delignification

    SciTech Connect (OSTI)

    Arthur J. Ragauskas

    2005-09-30

    The overall objective of this program was to develop improved extended oxygen delignification (EOD) technologies for current U.S. pulp mill operations. This was accomplished by: (1) Identifying pulping conditions that optimize O and OO performance; (2) Identifying structural features of lignin that enhance reactivity towards EOD of high kappa pulps; (3) Identifying factors minimizing carbohydrate degradation and improve pulp strength of EOD high kappa pulps; (4) Developing a simple, reproducible method of quantifying yield gains from EOD; and (5) Developing process conditions that significantly reduce the capital requirements of EOD while optimizing the yield benefits. Key research outcomes included, demonstrating the use of a mini-O sequence such as (E+O)Dkf:0.05(E+O) or Dkf:0.05(E+O)(E+O) without interstage washing could capture approximately 60% of the delignification efficiency of a conventional O-stage without the major capital requirements associated with an O-stage for conventional SW kraft pulps. The rate of formation and loss of fiber charge during an O-stage stage can be employed to maximize net fiber charge. Optimal fiber charge development and delignification are two independent parameters and do not parallel each other. It is possible to utilize an O-stage to enhance overall cellulosic fiber charge of low and high kappa SW kraft pulps which is beneficial for physical strength properties. The application of NIR and multi-variant analysis was developed into a rapid and simple method of determining the yield of pulp from an oxygen delignification stage that has real-world mill applications. A focus point of this program was the demonstration that Kraft pulping conditions and oxygen delignification of high and low-kappa SW and HW pulps are intimately related. Improved physical pulp properties and yield can be delivered by controlling the H-factor and active alkali charge. Low AA softwood kraft pulp with a kappa number 30 has an average improvement of 2% in yield and 4 cP in viscosity in comparison to high AA pulp for the oxygen delignification. This difference is also seen for high-kappa SW kraft pulps with an average improvement of {approx}3% in yield and 3 cP in viscosity for low AA high kappa number 50 pulp. Low AA hardwood kappa number 20 pulp had an average improvement of {approx}4% in yield and 6-12 cP in viscosity as compared to high AA pulp. Lower kraft cooking temperature (160 vs. 170 C) in combination with the medium AA provides a practical approach for integrating high kappa pulping of hardwoods (i.e., low rejects) with an advanced extended oxygen delignification stage. ECF pulp bleaching of low and high kappa kraft SW and HW pulps exhibit comparable optical and physical strength properties when bleached D(EPO)D.

  2. California high speed rail proposal: “High speed rail and wildlife”

    E-Print Network [OSTI]

    Wilkerson, Cynthia

    2005-01-01

    Chapter Wildlife and High Speed Rail C ALIFORNIA H IGH SDan Leavitt, California High Speed Rail Authority) AbstractThe California High Speed Rail (HSR) Proposal is in the

  3. Novel Refractory Materials for High-Temperature, High-Alkaline...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Applications Can be used in high-temperature, high-alkaline furnaces and process vessels found in aluminum, chemical, forest products, glass, and steel industries....

  4. Mesoporous Manganese Oxide Nanowires for High-Capacity, High...

    Office of Scientific and Technical Information (OSTI)

    Mesoporous Manganese Oxide Nanowires for High-Capacity, High-Rate, Hybrid Electrical Energy Storage Citation Details In-Document Search Title: Mesoporous Manganese Oxide Nanowires...

  5. High Temperature ESP Monitoring

    SciTech Connect (OSTI)

    Jack Booker; Brindesh Dhruva

    2011-06-20

    The objective of the High Temperature ESP Monitoring project was to develop a downhole monitoring system to be used in wells with bottom hole well temperatures up to 300°C for measuring motor temperature, formation pressure, and formation temperature. These measurements are used to monitor the health of the ESP motor, to track the downhole operating conditions, and to optimize the pump operation. A 220 ºC based High Temperature ESP Monitoring system was commercially released for sale with Schlumberger ESP motors April of 2011 and a 250 ºC system with will be commercially released at the end of Q2 2011. The measurement system is now fully qualified, except for the sensor, at 300 °C.

  6. High frequency reference electrode

    DOE Patents [OSTI]

    Kronberg, J.W.

    1994-05-31

    A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or halo' at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes. 4 figs.

  7. High frequency reference electrode

    DOE Patents [OSTI]

    Kronberg, James W. (Aiken, SC)

    1994-01-01

    A high frequency reference electrode for electrochemical experiments comprises a mercury-calomel or silver-silver chloride reference electrode with a layer of platinum around it and a layer of a chemically and electrically resistant material such as TEFLON around the platinum covering all but a small ring or "halo" at the tip of the reference electrode, adjacent to the active portion of the reference electrode. The voltage output of the platinum layer, which serves as a redox electrode, and that of the reference electrode are coupled by a capacitor or a set of capacitors and the coupled output transmitted to a standard laboratory potentiostat. The platinum may be applied by thermal decomposition to the surface of the reference electrode. The electrode provides superior high-frequency response over conventional electrodes.

  8. Ultra High Energy Fermions

    E-Print Network [OSTI]

    Burra G. Sidharth

    2015-04-07

    The LHC in Geneva is already operating at a total energy of $7 TeV$ and hopefully after a pause in 2012, it will attain its full capacity of $14 TeV$ in 2013. These are the highest energies achieved todate in any accelerator. It is against this backdrop that it is worthwhile to revisit very high energy collisions of Fermions (Cf. also \\cite{bgspp}). We will in fact examine their behaviour at such energies.

  9. High voltage pulse conditioning

    DOE Patents [OSTI]

    Springfield, Ray M. (Sante Fe, NM); Wheat, Jr., Robert M. (Los Alamos, NM)

    1990-01-01

    Apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close.

  10. High current ion source

    DOE Patents [OSTI]

    Brown, Ian G. (1088 Woodside Rd., Berkeley, CA 94708); MacGill, Robert A. (645 Kern St., Richmond, CA 94805); Galvin, James E. (2 Commodore Dr. #276, Emeryville, CA 94608)

    1990-01-01

    An ion source utilizing a cathode and anode for producing an electric arc therebetween. The arc is sufficient to vaporize a portion of the cathode to form a plasma. The plasma leaves the generation region and expands through another regon. The density profile of the plasma may be flattened using a magnetic field formed within a vacuum chamber. Ions are extracted from the plasma to produce a high current broad on beam.

  11. High Performance Window Attachments

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum12,ExecutiveFinancing ProgramsDepartment of¡High PerformancePerformance

  12. High pressure ceramic joint

    DOE Patents [OSTI]

    Ward, Michael E. (Poway, CA); Harkins, Bruce D. (San Diego, CA)

    1993-01-01

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures.

  13. High pressure ceramic joint

    DOE Patents [OSTI]

    Ward, M.E.; Harkins, B.D.

    1993-11-30

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures. 4 figures.

  14. High Energy Density Microwaves

    SciTech Connect (OSTI)

    Phillips, R.M. [Stanford Linear Accelerator Center, Stanford, CA 94309 (United States)

    1999-04-01

    These proceedings represent papers presented at the RF98 Workshop entitled `High Energy Density Microwaves` held in California in October, 1998. The topics discussed were predominantly accelerator{minus}related. The Workshop dealt, for the most part, with the generation and control of electron beams, the amplification of RF signals, the design of mode converters, and the effect of very high RF field gradients. This Workshop was designed to address the concerns of the microwave tube industry worldwide, the plasma physicists who deal with very high beam currents and gigawatts of RF power, and researchers in accelerator centers around the world. Papers were presented on multibeam klystrons, gyrotron development, plasmas in microwave tubes, RF breakdown, and alternatives to conventional linear coliders at 1 TeV and above. The Workshop was partially sponsored by the US Department of Energy. There were 46 papers presented at the conference,out of which 19 have been abstracted for the Energy,Science and Technology database.(AIP)

  15. High temperature interfacial superconductivity

    DOE Patents [OSTI]

    Bozovic, Ivan (Mount Sinai, NY); Logvenov, Gennady (Port Jefferson Station, NY); Gozar, Adrian Mihai (Port Jefferson, NY)

    2012-06-19

    High-temperature superconductivity confined to nanometer-scale interfaces has been a long standing goal because of potential applications in electronic devices. The spontaneous formation of a superconducting interface in bilayers consisting of an insulator (La.sub.2CuO.sub.4) and a metal (La.sub.1-xSr.sub.xCuO.sub.4), neither of which is superconducting per se, is described. Depending upon the layering sequence of the bilayers, T.sub.c may be either .about.15 K or .about.30 K. This highly robust phenomenon is confined to within 2-3 nm around the interface. After exposing the bilayer to ozone, T.sub.c exceeds 50 K and this enhanced superconductivity is also shown to originate from a 1 to 2 unit cell thick interfacial layer. The results demonstrate that engineering artificial heterostructures provides a novel, unconventional way to fabricate stable, quasi two-dimensional high T.sub.c phases and to significantly enhance superconducting properties in other superconductors. The superconducting interface may be implemented, for example, in SIS tunnel junctions or a SuFET.

  16. High energy physics

    SciTech Connect (OSTI)

    Kernan, A.; Shen, B.C.; Ma, E.

    1997-07-01

    This proposal is for the continuation of the High Energy Physics program at the University of California at Riverside. In hadron collider physics the authors will complete their transition from experiment UA1 at CERN to the DZERO experiment at Fermilab. On experiment UA1 their effort will concentrate on data analysis at Riverside. At Fermilab they will coordinate the high voltage system for all detector elements. They will also carry out hardware/software development for the D0 muon detector. The TPC/Two-Gamma experiment has completed its present phase of data-taking after accumulating 160 pb{sup {minus}}1 of luminosity. The UC Riverside group will continue data and physics analysis and make minor hardware improvement for the high luminosity run. The UC Riverside group is participating in design and implementation of the data acquisition system for the OPAL experiment at LEP. Mechanical and electronics construction of the OPAL hadron calorimeter strip readout system is proceeding on schedule. Data analysis and Monte Carlo detector simulation efforts are proceeding in preparation for the first physics run when IEP operation comenses in fall 1989.

  17. Reactions to Value Pricing by Different Suburban Population Groups 

    E-Print Network [OSTI]

    Lowery, John

    2011-08-08

    that is automatically collected and deducted from the driver?s pre-paid MnPass account. The amount of the toll charged to single occupant vehicles varies based on the level of congestion on the lanes and is displayed to motorists using variable message signs (see...). All vehicles traveling on the lanes must carry a transponder used to deduct the toll from a prepaid account. Vehicles eligible to use the lanes for free or at a discounted rate are required to travel in a designated lane as shown in Figure 2...

  18. High Performance Computing School COMSC

    E-Print Network [OSTI]

    Martin, Ralph R.

    High Performance Computing School COMSC This module aims to provide the students with fundamental knowledge and understanding of techniques associated with High Performance Computing and its practical' skills in analysing and evaluating High Performance Computing and will be structured around

  19. High Energy Density Laboratory Plasmas

    E-Print Network [OSTI]

    High Energy Density Laboratory Plasmas General Plasma Science Developing founda/ons and advancing fundamental understanding #12;The High Energy Density developing innovative techniques to study the properties of instabilities in magnetized-high-energy-density

  20. High Performance Computing Center IT DIVISION -HIGH PERFORMANCE COMPUTING CENTER

    E-Print Network [OSTI]

    Rock, Chris

    . It will ensure that Texas Tech retains superior computing and visualization facilities. #12;High PerformanceHigh Performance Computing Center 9/27/2004 1 IT DIVISION - HIGH PERFORMANCE COMPUTING CENTER STRATEGIC PLAN MISSION STATEMENT The High Performance Computing Center (HPCC) promotes research and teaching