Powered by Deep Web Technologies
Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Marin County- Wood Stove Replacement Rebate Program  

Broader source: Energy.gov [DOE]

The County of Marin has created a rebate program to encourage homeowners to remove or replace non-EPA certified wood-burning heaters (wood stoves and fireplace inserts) with cleaner burning stoves...

2

Qualifying Wood Stove Deduction | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Qualifying Wood Stove Deduction Qualifying Wood Stove Deduction Qualifying Wood Stove Deduction < Back Eligibility Residential Savings Category Bioenergy Maximum Rebate 500 Program Info Start Date 1/1/1994 State Arizona Program Type Personal Deduction Rebate Amount Total cost, exclusive of taxes, interest and other finance charges Provider Arizona Department of Revenue This incentive allows Arizona taxpayers to deduct the cost of converting an existing wood fireplace to a qualifying wood stove. The cost to purchase and install all necessary equipment is tax deductible, up to a maximum $500 deduction. Qualifying wood stoves must meet the standards of performance for new wood heaters manufactured after July 1990, or sold after July 1992 pursuant to [http://www.epa.gov/oecaerth/resources/policies/monitoring/caa/woodstover...

3

Clean-Burning Wood Stove Grant Program (Maryland) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Clean-Burning Wood Stove Grant Program (Maryland) Clean-Burning Wood Stove Grant Program (Maryland) Clean-Burning Wood Stove Grant Program (Maryland) < Back Eligibility Residential Savings Category Bioenergy Program Info Start Date 09/07/2012 State Maryland Program Type State Rebate Program Rebate Amount Stick Burning Stove: $500 Pellet Burning Stove: $700 The Maryland Energy Administration (MEA) now offers the Clean Burning Wood Stove Grant program as part of its Residential Clean Energy Grant Program. The Clean Burning Wood Stove Grant program offers a flat grant award of $500 for stick burning wood stoves and $700 for pellet burning wood stoves that meet program eligibility requirements. Basic requirements for grant funding include: *The property must serve as primary residence *Clean burning wood stove must replace existing electric or non-natural gas

4

Definition: Biomass Cook Stove | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Biomass Cook Stove Jump to: navigation, search Dictionary.png Biomass Cook Stove A Stove that is heated by burning wood, charcoal, animal dung or crop residue. Cook stoves are the most common way of cooking and heating food in developing countries.[1] View on Wikipedia Wikipedia Definition "Cooking stove" redirects here. For a kitchen cooker, stove, range, oven, or stove top, see Kitchen stove. In cooking, a cook stove is heated by burning wood, charcoal, animal dung or crop residue. Cook stoves are commonly used for cooking and heating food in developing countries. Developing countries consume little energy compared to developed nations; however, over 50% of the energy that they do use goes into cooking food.

5

Influence of chimneys on combustion characteristics of buoyantly driven biomass stoves  

Science Journals Connector (OSTI)

Abstract This work examines whether a chimney has influence over the combustion characteristics of biomass within a stove. Experimental work as well as a simplified chemical kinetic model suggests that a chimney plays an active role in the performance of a stove by influencing the overall air-to-fuel ratio and subsequently the production of carbon monoxide. Two different stoves, operated at multiple wood consumption rates, were shown to run with steady state excess air of 300 % ? 1250 %. The wood consumption rate was found to be independent of the chimney draft for both stoves. Increasing draft was shown to increase excess air. Draft served to cool combustion gases through dilution with makeup air. Increasing excess air decreased modified combustion efficiency in experiments and kinetic modeling. Increasing the frictional loss coefficient of a chimney by decreasing the diameter was shown to reduce CO production through a reduction of excess air.

J. Prapas; M.E. Baumgardner; A.J. Marchese; B. Willson; M. DeFoort

2014-01-01T23:59:59.000Z

6

Wood and Pellet Heating | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Wood and Pellet Heating Wood and Pellet Heating Wood and Pellet Heating November 25, 2013 - 2:24pm Addthis A wood stove on a stone hearth. | Photo courtesy of ©iStockphoto/King_Louie A wood stove on a stone hearth. | Photo courtesy of ©iStockphoto/King_Louie What does this mean for me? Wood or pellets may be an economical and environmentally sound heating fuel choice. If you live in an area where you can cut your own wood for heating, your fuel will be local and inexpensive. Today you can choose from a new generation of wood- and pellet-burning appliances that are cleaner burning, more efficient, and powerful enough to heat many average-sized, modern homes. Pellet fuel appliances burn small pellets that measure 3/8 to 1 inch in length. Choosing and Installing Wood- and Pellet-Burning Appliances

7

Convective heater  

DOE Patents [OSTI]

A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation.

Thorogood, Robert M. (Macungie, PA)

1983-01-01T23:59:59.000Z

8

Convective heater  

DOE Patents [OSTI]

A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation.

Thorogood, Robert M. (Macungie, PA)

1986-01-01T23:59:59.000Z

9

Development of thermoacoustic engine operating by waste heat from cooking stove  

Science Journals Connector (OSTI)

There are about 1.5 billion people worldwide use biomass as their primary form of energy in household cooking[1]. They do not have access to electricity and are too remote to benefit from grid electrical supply. In many rural communities stoves are made without technical advancements mostly using open fires cooking stoves which have been proven to be extremely low efficiency and about 93% of the energy generated is lost during cooking. The cooking is done inside a dwelling and creates significant health hazard to the family members and pollution to environment. SCORE (www.score.uk.com) is an international collaboration research project to design and build a low-cost high efficiency woodstove that uses about half amount of the wood of an open wood fire and uses the waste heat of the stove to power a thermoacoustic engine (TAE) to produce electricity for applications such as LED lighting charging mobile phones or charging a 12V battery. This paper reviews on the development of two types of the thermoacoustic engine powered by waste heat from cooking stove which is either using Propane gas or burning of wood as a cooking energy to produce an acceptable amount of electricity for the use of rural communities.

2012-01-01T23:59:59.000Z

10

Development and Testing of the Berkeley Darfur Stove  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Development and Testing of the Berkeley Darfur Stove Development and Testing of the Berkeley Darfur Stove Title Development and Testing of the Berkeley Darfur Stove Publication Type Report LBNL Report Number LBNL-116E Year of Publication 2008 Authors Amrose, Susan, G. Theodore Kisch, Charles Kirubi, Jesse Woo, and Ashok J. Gadgil Date Published 03/2008 Publisher Lawrence Berkeley National Laboratory City Berkeley Abstract Darfur, one of the poorest regions in Sudan, has been in the midst of a complicated and bloody conflict since 2003 that has resulted in the displacement of 2.2 million citizens. The displaced, known as Internally Displaced Persons (IDPs), are crowded into refugee camps scattered across the region with low fuelwood productivity and no alternative means of fuel. Unsustainable harvesting has led to increasing zones of total denudation around the camps, now extending several kilometers in all directions from the camp boundaries. Women who leave the camp to fetch fuelwood are subject to rape and mutilation due to the continuing conflict.In November of 2005, a team of scientists from LBNL visited Darfur to assess the potential of fuel-efficient stoves ("FES") as a means to mitigate the fuelwood shortage. In addition to conducting a systematic informal survey, the team found that a metal FES, known as the Tara, required 50% less fuelwood to cook an IDP meal than the inefficient three-stone-fire used by 90% of the IDPs. The LBNL team emerged from the triprecommending a metal FES based on the Tara, but with two specific design modifications to make it suitable for conditions in Darfur. These included improving the mechanical stability of the stove during vigorous stirring, and maintaining or improving performance during a breeze. In Spring 2006, an interdisciplinary team of four Berkeley students (3 graduate and 1 senior undergraduate) took on the project of designing, fabricating, and testing the recommended modifications as part of a UC-Berkeley course entitled Design forSustainable Communities. Under the guidance of Prof. Ashok Gadgil, the students designed several modifications to improve stove performance in windy weather, including a wind-shield around the upper stove body, and the addition of a metal ring to prevent direct air flow through the stove body. Stakes were also added to the stove body to improve stability during vigorous stirring. The students fabricated a prototype fortesting, known as the "Berkeley Darfur Stove," or BDS. Since no existing stove test was relevant to the conditions of Darfur, a new protocol, known as the Darfur Cooking Test (DCT), was developed by the students to compare the fuel efficiency of two stoves. This protocol is specific to the conditions in Darfur, incorporating both windy and non-windy conditions, along with the cooking pots, food preparation methods, and meals employed by IDPs. The complete DCT protocol is presented in Appendices 1 and 2. The BDS prototype was tested against the original Tara stove using the newly developed DCT along with a simple tipping test (to compare stability). Fuelwood usage by the BDS was found to be consistently less than that of the Tara stove under all tested conditions. Compared to the Tara, the BDS was found to save 56% (with wind) and 40% (without wind) of the fuelwood required to cook sauce-like mulah (one of two staple IDP foods)and to save 74% (with wind) and 8% (without wind) of the fuelwood required to cook the dough-like assida (the other staple food). Using these numbers, the BDS was found to have a net annual fuelwood savings of 72% over the three-stone-fire in Darfur. The 4 stability of the BDS during stirring was also found to be much better than the Tara, requiring > 117 N of lateral force to tip compared to just 22 N. Implications of full adoption of the BDS throughout Darfur include saving 370 million kg of fuelwood per year, along with a monetary savings of US $222 per family per year for IDPs who buy fuelwood or a savings of 18 hours of labor effort per week for IDPs who currently collect fuelwood. Annual avoided CO2 emissions would come to 6 million tonnes per year worth $12 million annually assuming the lowest market price of $3 per tonne1 of CO2. Most significantly, the risk of rape and mutilation for those who collect fuelwood would be reduced by three-quarters. Additional expected benefits include substantial reduction in the inhalation of harmful wood-smoke by IDP women and girls, and significant reduction in the risk of fire to the IDP shelters because the BDS fully encloses the open flames.

11

Indoor Levels of Polycyclic Aromatic Hydrocarbons in Homes with or without Wood Burning for Heating  

Science Journals Connector (OSTI)

Indoor Levels of Polycyclic Aromatic Hydrocarbons in Homes with or without Wood Burning for Heating ... One wood-burning home had a boiler located in a shelter outside the house and was excluded from the study. ... The concentrations of BaP in the wood-burning homes (0.52 ng/m3) were within the range reported for an American home during operation of different airtight wood stoves (20) and for seven homes during wood burning in airtight wood stoves (21). ...

Pernilla Gustafson; Conny stman; Gerd Sllsten

2008-06-07T23:59:59.000Z

12

Heat Pump Water Heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Water Heaters Showerheads Residential Weatherization Performance Tested Comfort Systems Ductless Heat Pumps New Construction Residential Marketing Toolkit Retail Sales...

13

Selecting a new water heater  

SciTech Connect (OSTI)

This fact sheet describes the types of water heaters available (storage water heaters, demand water heaters, heat pump water heaters, tankless coil and indirect water heaters, and solar water heaters). The criteria for selection are discussed. These are capacity, efficiency rating, and cost. A resource list is provided for further information.

NONE

1995-03-01T23:59:59.000Z

14

Swimming Pool Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Energy Efficiency Homes Water Heating Swimming Pool Heaters Swimming Pool Heaters July 10, 2014 Gas Swimming Pool Heaters Selecting the right kind of swimming pool heater...

15

Grouped exposed metal heaters  

DOE Patents [OSTI]

A system for treating a hydrocarbon containing formation is described. The system includes two or more groups of elongated heaters. The group includes two or more heaters placed in two or more openings in the formation. The heaters in the group are electrically coupled below the surface of the formation. The openings include at least partially uncased wellbores in a hydrocarbon layer of the formation. The groups are electrically configured such that current flow through the formation between at least two groups is inhibited. The heaters are configured to provide heat to the formation.

Vinegar, Harold J. (Bellaire, TX); Coit, William George (Bellaire, TX); Griffin, Peter Terry (Brixham, GB); Hamilton, Paul Taylor (Houston, TX); Hsu, Chia-Fu (Granada Hills, CA); Mason, Stanley Leroy (Allen, TX); Samuel, Allan James (Kular Lumpar, MY); Watkins, Ronnie Wade (Cypress, TX)

2010-11-09T23:59:59.000Z

16

Quantifying Stove Emissions Related to Different Use Patterns for the  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Stove Emissions Related to Different Use Patterns for the Stove Emissions Related to Different Use Patterns for the Silver-mini (Small Turkish) Space Heating Stove Title Quantifying Stove Emissions Related to Different Use Patterns for the Silver-mini (Small Turkish) Space Heating Stove Publication Type Report LBNL Report Number LBNL-6319E Year of Publication 2013 Authors Maddalena, Randy L., Melissa M. Lunden, Daniel Wilson, Cristina Ceballos, Thomas W. Kirchstetter, Jonathan L. Slack, and Larry L. Dale Publisher Lawrence Berkeley National Laboratory City Berkeley Abstract Air pollution levels in Ulaanbaatar, Mongolia's capital, are among the highest in the world. A primary source of this pollution is emissions from traditional coal-burning space heating stoves used in the Ger (tent) regions around Ulaanbaatar. Significant investment has been made to replace traditional heating stoves with improved low-emission high-efficiency stoves. Testing performed to support selection of replacement stoves or for optimizing performance may not be representative of true field performance of the improved stoves. Field observations and lab measurements indicate that performance is impacted, often adversely, by how stoves are actually being used in the field. The objective of this project is to identify factors that influence stove emissions under typical field operating conditions and to quantify the impact of these factors. A highly-instrumented stove testing facility was constructed to allow for rapid and precise adjustment of factors influencing stove performance. Tests were performed using one of the improved stove models currently available in Ulaanbaatar. Complete burn cycles were conducted with Nailakh coal from the Ulaanbaatar region

17

Sustainable Energy Resources for Consumers (SERC) Success Story...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

these installations were elderly and had previously relied on heat from expensive electric baseboard heaters or even wood stoves that they had to constantly tend to for...

18

Explosives tester with heater  

DOE Patents [OSTI]

An inspection tester system for testing for explosives. The tester includes a body and a swab unit adapted to be removeably connected to the body. At least one reagent holder and dispenser is operatively connected to the body. The reagent holder and dispenser contains an explosives detecting reagent and is positioned to deliver the explosives detecting reagent to the swab unit. A heater is operatively connected to the body and the swab unit is adapted to be operatively connected to the heater.

Del Eckels, Joel (Livermore, CA); Nunes, Peter J. (Danville, CA); Simpson, Randall L. (Livermore, CA); Whipple, Richard E. (Livermore, CA); Carter, J. Chance (Livermore, CA); Reynolds, John G. (San Ramon, CA)

2010-08-10T23:59:59.000Z

19

Department of Energy - Swimming Pool Heaters  

Broader source: Energy.gov (indexed) [DOE]

736189 en Gas Swimming Pool Heaters http:energy.govenergysaverarticlesgas-swimming-pool-heaters heaters" class"title-link">

20

Floating solar pool heater  

SciTech Connect (OSTI)

A floating solar heater for swimming pools is disclosed which includes a top cover, a vertical outer side wall with inclined inner side wall segments connected thereto, an outside rim and a bottom wall. The inner side wall segments are octagonal, coated with light reflective material, and aid in reflecting the sun's rays to heat the space inside the walls formed by the cover which dead air space also provides for floatation of the heater. The bottom wall is heated by direct sun inpingement and by the air in contact with it and is formed of a material having high heat conductivity.

McCluskey, J.E.

1981-08-18T23:59:59.000Z

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Portable Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Portable Heaters Portable Heaters Portable Heaters November 26, 2013 - 2:41pm Addthis Portable heaters can be an efficient way to supplement inadequate heating. | Photo courtesy iStockphoto.com Portable heaters can be an efficient way to supplement inadequate heating. | Photo courtesy iStockphoto.com What does this mean for me? A portable heater is a good choice if you have a space that requires supplemental heating or is infrequently occupied. You should carefully follow all the manufacturer's installation and operation instructions. Small space heaters are typically used when the main heating system is inadequate or when central heating is too costly to install or operate. In some cases, small space heaters can be less expensive to use if you only want to heat one room or supplement inadequate heating in one room. They

22

Energy Conservation in Process Heaters  

E-Print Network [OSTI]

ENERGY CONSERVATION IN PROCESS HEATERS Roger l~. Bagge Neste Engineering Porvoo, Finland ABSTRACT OPTIMIZATION OF EMER~Y USE Energy savings in refinery and petrochemical fired heaters can basically be achieved in two ways: Thru optimization...

Bagge, R. W.

1982-01-01T23:59:59.000Z

23

Absorption Heat Pump Water Heater  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Absorption Heat Pump Water Heater Absorption Heat Pump Water Heater Kyle Gluesenkamp Building Equipment Group, ETSD gluesenkampk@ornl.gov 865-241-2952 April 3, 2013 CRADA - GE Development of High Performance Residential Gas Water Heater Image courtesy John Wilkes 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: Absorption technology could greatly boost water heater efficiency, but faces barriers of high first cost and working fluid challenges. Impact of Project: Energy factor of gas storage water

24

Absorption Heat Pump Water Heater  

Broader source: Energy.gov (indexed) [DOE]

Absorption Heat Pump Water Heater Absorption Heat Pump Water Heater Kyle Gluesenkamp Building Equipment Group, ETSD gluesenkampk@ornl.gov 865-241-2952 April 3, 2013 CRADA - GE Development of High Performance Residential Gas Water Heater Image courtesy John Wilkes 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: Absorption technology could greatly boost water heater efficiency, but faces barriers of high first cost and working fluid challenges. Impact of Project: Energy factor of gas storage water

25

Dehumidifying water heater  

SciTech Connect (OSTI)

The indoor swimming pool at the Glen Cove YMCA in Glen Cove, New York, has been selected for the dehumidification/water heating system demonstration project. This report provides the specifications for this system which includes a dehumidifier/air handler, condenser/water heater, and outdoor condenser. Current progress underway includes construction, vendor selection, and control system selection. (SM)

Stark, W.

1991-05-31T23:59:59.000Z

26

Immersible solar heater for fluids  

DOE Patents [OSTI]

An immersible solar heater comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

Kronberg, James W. (Aiken, SC)

1995-01-01T23:59:59.000Z

27

Residential Sector End-Use Forecasting with EPRI-REEPS 2.1: Summary Input Assumptions and Results  

E-Print Network [OSTI]

LPG Furnace Oil Furnace Electric Heat Pump Gas BoilerOil Boiler Electric Room Heater Gas Room Heater Wood Stove (Electric Heat Pump Gas Boiler Oil Boiler Electric Room Gas

Koomey, Jonathan G.

2010-01-01T23:59:59.000Z

28

Do You Have a Solar Water Heater?  

Broader source: Energy.gov [DOE]

Earlier this week, Ernie wrote about theeconomics of getting a solar water heater. As Ernie explained, a solar water heater is more expensive than a normal water heater, but depending on your area...

29

Immersible solar heater for fluids  

DOE Patents [OSTI]

An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

Hazen, T.C.; Fliermans, C.B.

1994-01-01T23:59:59.000Z

30

Immersible solar heater for fluids  

DOE Patents [OSTI]

An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater. 11 figs.

Kronberg, J.W.

1995-07-11T23:59:59.000Z

31

Advanced Hybrid Water Heater using Electrochemical Compressor...  

Energy Savers [EERE]

Advanced Hybrid Water Heater using Electrochemical Compressor Advanced Hybrid Water Heater using Electrochemical Compressor Xergy is using its Electro Chemical Compression (ECC)...

32

Tankless Gas Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tankless Gas Water Heaters Tankless Gas Water Heaters Standardized Templates for Reporting Test Results tanklessgaswaterheaterv12.xlsx More Documents & Publications Heat Pump...

33

Commercial Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Water Heaters Commercial Water Heaters Standardized DOE Testing Templates commercialwaterheater v1.0.xlsx More Documents & Publications Refrigerators and Refrigerator-Freezers...

34

Storage Gas Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Storage Gas Water Heaters Storage Gas Water Heaters The Department of Energy (DOE) develops standardized data templates for reporting the results of tests conducted in accordance...

35

Heat Pump Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Heat Pump Water Heaters Heat Pump Water Heaters Standardized Templates for Reporting Test Results heatpumpwaterheaterv1.7.xlsx More Documents & Publications Tankless Gas Water...

36

Methods for forming long subsurface heaters  

DOE Patents [OSTI]

A method for forming a longitudinal subsurface heater includes longitudinally welding an electrically conductive sheath of an insulated conductor heater along at least one longitudinal strip of metal. The longitudinal strip is formed into a tubular around the insulated conductor heater with the insulated conductor heater welded along the inside surface of the tubular.

Kim, Dong Sub

2013-09-17T23:59:59.000Z

37

Experimental analysis of stove top designs for pine needle combustion in a semi-gasifier burner  

E-Print Network [OSTI]

The motivation behind this project was to develop a better understanding of the role that the stove top plays in a stove where pine needles are the main fuel source. Pine needles have distinct characteristics in their ...

Roqu, Alyssa J

2011-01-01T23:59:59.000Z

38

Heater head for stirling engine  

DOE Patents [OSTI]

A monolithic heater head assembly which augments cast fins with ceramic inserts which narrow the flow of combustion gas and obtains high thermal effectiveness with the assembly including an improved flange design which gives greater durability and reduced conduction loss.

Corey, John A. (R.D. #2, Box 101 E, North Troy, NY 12182)

1985-07-09T23:59:59.000Z

39

Improved Biomass Cooking Stoves | Open Energy Information  

Open Energy Info (EERE)

Improved Biomass Cooking Stoves Improved Biomass Cooking Stoves Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Improved Biomass Cooking Stoves Agency/Company /Organization: various Sector: Energy Focus Area: Biomass Phase: Determine Baseline, Evaluate Options, Prepare a Plan, Create Early Successes Topics: Co-benefits assessment, - Energy Access Resource Type: Case studies/examples, Guide/manual, Presentation, Video User Interface: Website Website: ttp://www.bioenergylists.org/ Cost: Free Language: "English, Spanish; Castilian" is not in the list of possible values (Abkhazian, Achinese, Acoli, Adangme, Adyghe; Adygei, Afar, Afrihili, Afrikaans, Afro-Asiatic languages, Ainu, Akan, Akkadian, Albanian, Aleut, Algonquian languages, Altaic languages, Amharic, Angika, Apache languages, Arabic, Aragonese, Arapaho, Arawak, Armenian, Aromanian; Arumanian; Macedo-Romanian, Artificial languages, Assamese, Asturian; Bable; Leonese; Asturleonese, Athapascan languages, Australian languages, Austronesian languages, Avaric, Avestan, Awadhi, Aymara, Azerbaijani, Balinese, Baltic languages, Baluchi, Bambara, Bamileke languages, Banda languages, Bantu (Other), Basa, Bashkir, Basque, Batak languages, Beja; Bedawiyet, Belarusian, Bemba, Bengali, Berber languages, Bhojpuri, Bihari languages, Bikol, Bini; Edo, Bislama, Blin; Bilin, Blissymbols; Blissymbolics; Bliss, Bosnian, Braj, Breton, Buginese, Bulgarian, Buriat, Burmese, Caddo, Catalan; Valencian, Caucasian languages, Cebuano, Celtic languages, Central American Indian languages, Central Khmer, Chagatai, Chamic languages, Chamorro, Chechen, Cherokee, Cheyenne, Chibcha, Chichewa; Chewa; Nyanja, Chinese, Chinook jargon, Chipewyan; Dene Suline, Choctaw, Chuukese, Chuvash, Classical Newari; Old Newari; Classical Nepal Bhasa, Classical Syriac, Coptic, Cornish, Corsican, Cree, Creek, Creoles and pidgins , Crimean Tatar; Crimean Turkish, Croatian, Cushitic languages, Czech, Dakota, Danish, Dargwa, Delaware, Dinka, Divehi; Dhivehi; Maldivian, Dogri, Dogrib, Dravidian languages, Duala, Dutch; Flemish, Dyula, Dzongkha, Eastern Frisian, Efik, Egyptian (Ancient), Ekajuk, Elamite, English, Erzya, Esperanto, Estonian, Ewe, Ewondo, Fang, Fanti, Faroese, Fijian, Filipino; Pilipino, Finnish, Finno-Ugrian languages, Fon, French, Friulian, Fulah, Ga, Gaelic; Scottish Gaelic, Galibi Carib, Galician, Ganda, Gayo, Gbaya, Geez, Georgian, German, Germanic languages, Gilbertese, Gondi, Gorontalo, Gothic, Grebo, Greek, Modern, Guarani, Gujarati, Gwich'in, Haida, Haitian; Haitian Creole, Hausa, Hawaiian, Hebrew, Herero, Hiligaynon, Himachali languages; Western Pahari languages, Hindi, Hiri Motu, Hittite, Hmong; Mong, Hungarian, Hupa, Iban, Icelandic, Ido, Igbo, Ijo languages, Iloko, Inari Sami, Indic languages, Indo-European languages, Indonesian, Ingush, Interlingue; Occidental, Inuktitut, Inupiaq, Iranian languages, Irish, Iroquoian languages, Italian, Japanese, Javanese, Judeo-Arabic, Judeo-Persian, Kabardian, Kabyle, Kachin; Jingpho, Kalaallisut; Greenlandic, Kalmyk; Oirat, Kamba, Kannada, Kanuri, Kara-Kalpak, Karachay-Balkar, Karelian, Karen languages, Kashmiri, Kashubian, Kawi, Kazakh, Khasi, Khoisan languages, Khotanese; Sakan, Kikuyu; Gikuyu, Kimbundu, Kinyarwanda, Kirghiz; Kyrgyz, Klingon; tlhIngan-Hol, Komi, Kongo, Konkani, Korean, Kosraean, Kpelle, Kru languages, Kuanyama; Kwanyama, Kumyk, Kurdish, Kurukh, Kutenai, Ladino, Lahnda, Lamba, Land Dayak languages, Lao, Latin, Latvian, Lezghian, Limburgan; Limburger; Limburgish, Lingala, Lithuanian, Lojban, Lower Sorbian, Lozi, Luba-Katanga, Luba-Lulua, Luiseno, Lule Sami, Lunda, Luo (Kenya and Tanzania), Lushai, Luxembourgish; Letzeburgesch, Macedonian, Madurese, Magahi, Maithili, Makasar, Malagasy, Malay, Malayalam, Maltese, Manchu, Mandar, Mandingo, Manipuri, Manobo languages, Manx, Maori, Mapudungun; Mapuche, Marathi, Mari, Marshallese, Marwari, Masai, Mayan languages, Mende, Mi'kmaq; Micmac, Minangkabau, Mirandese, Mohawk, Moksha, Mon-Khmer languages, Mongo, Mongolian, Mossi, Multiple languages, Munda languages, N'Ko, Nahuatl languages, Nauru, Navajo; Navaho, Ndebele, North; North Ndebele, Ndebele, South; South Ndebele, Ndonga, Neapolitan, Nepal Bhasa; Newari, Nepali, Nias, Niger-Kordofanian languages, Nilo-Saharan languages, Niuean, North American Indian languages, Northern Frisian, Northern Sami, Norwegian, Nubian languages, Nyamwezi, Nyankole, Nyoro, Nzima, Occitan (post 1500); Provençal, Ojibwa, Oriya, Oromo, Osage, Ossetian; Ossetic, Otomian languages, Pahlavi, Palauan, Pali, Pampanga; Kapampangan, Pangasinan, Panjabi; Punjabi, Papiamento, Papuan languages, Pedi; Sepedi; Northern Sotho, Persian, Philippine languages, Phoenician, Pohnpeian, Polish, Portuguese, Prakrit languages, Pushto; Pashto, Quechua, Rajasthani, Rapanui, Rarotongan; Cook Islands Maori, Romance languages, Romanian; Moldavian; Moldovan, Romansh, Romany, Rundi, Russian, Salishan languages, Samaritan Aramaic, Sami languages, Samoan, Sandawe, Sango, Sanskrit, Santali, Sardinian, Sasak, Scots, Selkup, Semitic languages, Serbian, Serer, Shan, Shona, Sichuan Yi; Nuosu, Sicilian, Sidamo, Sign Languages, Siksika, Sindhi, Sinhala; Sinhalese, Sino-Tibetan languages, Siouan languages, Skolt Sami, Slave (Athapascan), Slavic languages, Slovak, Slovenian, Sogdian, Somali, Songhai languages, Soninke, Sorbian languages, Sotho, Southern, South American Indian (Other), Southern Altai, Southern Sami, Spanish; Castilian, Sranan Tongo, Sukuma, Sumerian, Sundanese, Susu, Swahili, Swati, Swedish, Swiss German; Alemannic; Alsatian, Syriac, Tagalog, Tahitian, Tai languages, Tajik, Tamashek, Tamil, Tatar, Telugu, Tereno, Tetum, Thai, Tibetan, Tigre, Tigrinya, Timne, Tiv, Tlingit, Tok Pisin, Tokelau, Tonga (Nyasa), Tonga (Tonga Islands), Tsimshian, Tsonga, Tswana, Tumbuka, Tupi languages, Turkish, Turkmen, Tuvalu, Tuvinian, Twi, Udmurt, Ugaritic, Uighur; Uyghur, Ukrainian, Umbundu, Uncoded languages, Undetermined, Upper Sorbian, Urdu, Uzbek, Vai, Venda, Vietnamese, Volapük, Votic, Wakashan languages, Walamo, Walloon, Waray, Washo, Welsh, Western Frisian, Wolof, Xhosa, Yakut, Yao, Yapese, Yiddish, Yoruba, Yupik languages, Zande languages, Zapotec, Zaza; Dimili; Dimli; Kirdki; Kirmanjki; Zazaki, Zenaga, Zhuang; Chuang, Zulu, Zuni) for this property.

40

Natural Gas Stove Emissions and Respiratory Health: Evidence from NHANES  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Natural Gas Stove Emissions and Respiratory Health: Evidence from NHANES Natural Gas Stove Emissions and Respiratory Health: Evidence from NHANES III Speaker(s): Ronald Briggs Date: August 15, 2007 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Brett Singer Do emissions from natural gas stoves in American homes degrade respiratory health? The combustion of natural gas yields byproducts such as NOx , PM2.5 , and CO that the US EPA regulates outdoors. But while ambient air quality has improved in the US over the last few decades as a consequence of the Clean Air Act of and its amendments, the prevalence of asthma and morbidity and mortality associated with asthma continue to rise (Mannino /et al./, 1998). Concentrations of most air pollutants are higher indoors than outdoors in the US, however, and people in the US spend more than 90%

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Fuel-Efficient Stove Programs in Humanitarian Settings | Open Energy  

Open Energy Info (EERE)

Fuel-Efficient Stove Programs in Humanitarian Settings Fuel-Efficient Stove Programs in Humanitarian Settings Jump to: navigation, search Tool Summary Name: Fuel-Efficient Stove Programs in Humanitarian Settings Agency/Company /Organization: USAID Sector: Energy Focus Area: Biomass, Energy Efficiency Phase: Evaluate Options, Prepare a Plan, Evaluate Effectiveness and Revise as Needed Resource Type: Guide/manual, Lessons learned/best practices, Presentation, Publications User Interface: Spreadsheet, Website Website: www.energytoolbox.org/cookstoves/ Cost: Free Language: English A step-by-step process of assessment, planning, implementation, and monitoring and evaluation of a Cookstove activity This Toolkit is designed to take you and your organization through a step-by-step process of assessment, planning, implementation, and

42

Heat Pump Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Water Heaters Water Heaters Heat Pump Water Heaters May 4, 2012 - 5:21pm Addthis A diagram of a heat pump water heater. A diagram of a heat pump water heater. What does this mean for me? Heat pump water heaters can be two to three times more energy efficient than conventional electric storage water heaters. Heat pump water heaters work in locations that remain in the 40º-90ºF range year-round. Most homeowners who have heat pumps use them to heat and cool their homes. But a heat pump also can be used to heat water -- either as stand-alone water heating system, or as combination water heating and space conditioning system. How They Work Heat pump water heaters use electricity to move heat from one place to another instead of generating heat directly. Therefore, they can be two to

43

Small Space Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Small Space Heater Basics Small Space Heater Basics Small Space Heater Basics August 19, 2013 - 10:38am Addthis Small space heaters, also called portable heaters, are typically used when the main heating system is inadequate or when central heating is too costly to install or operate. Space heater capacities generally range between 10,000 Btu to 40,000 Btu per hour. Common fuels used for this purpose are electricity, propane, natural gas, and kerosene. Although most space heaters rely on convection (the circulation of air in a room), some rely on radiant heating; that is, they emit infrared radiation that directly heats up objects and people that are within their line of sight. Combustion Space Heaters Space heaters are classified as vented and unvented, or "vent free." Unvented combustion units are not recommended for inside use, as they

44

Pollutant Emissions and Energy Efficiency of Chinese Gasifier Cooking Stoves and Implications for Future Intervention Studies  

Science Journals Connector (OSTI)

Pollutant Emissions and Energy Efficiency of Chinese Gasifier Cooking Stoves and Implications for Future Intervention Studies ... Medium power stove operation emitted nearly twice as much PM2.5 as was emitted during high power stove operation, and the lighting phase of a cooking event contributed 45% and 34% of total PM2.5 emissions (combined lighting and cooking). ... A smaller pot was used with stoves A and B (500g) compared with stoves C and D (675g), but both sizes could hold at least 5 L of water. ...

Ellison M. Carter; Ming Shan; Xudong Yang; Jiarong Li; Jill Baumgartner

2014-05-02T23:59:59.000Z

45

Tankless Gas Water Heater Performance - Building America Top...  

Energy Savers [EERE]

Tankless Gas Water Heater Performance - Building America Top Innovation Tankless Gas Water Heater Performance - Building America Top Innovation This photo shows a hot water heater...

46

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network [OSTI]

M.V. Lapsa. 2001. Residential Heat Pump Water Heater (HPWH)Calwell. 2005. Residential Heat Pump Water Heaters: Energyfor Residential Heat Pump Water Heaters Installed in

Franco, Victor

2011-01-01T23:59:59.000Z

47

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network [OSTI]

2001. Residential Heat Pump Water Heater (HPWH) Development2005. Residential Heat Pump Water Heaters: Energy Efficiencyfor Residential Heat Pump Water Heaters Installed in

Franco, Victor

2011-01-01T23:59:59.000Z

48

A performance correlation of horizontal solar heaters  

E-Print Network [OSTI]

The solar heaters are shown tn Figure VI, page 31 30 Figure VI Horizontal Solar Heaters ~GLAZING AND FRAME ~~ POLYETHYLENE HEATERS THERMAL IN S U LA T I N 8 CELLS THERMOCOUPLES HORIZONTAL TABLE TOP THERMOCOUPLES COPPER LEADS TO CONTROL... The solar heaters are shown tn Figure VI, page 31 30 Figure VI Horizontal Solar Heaters ~GLAZING AND FRAME ~~ POLYETHYLENE HEATERS THERMAL IN S U LA T I N 8 CELLS THERMOCOUPLES HORIZONTAL TABLE TOP THERMOCOUPLES COPPER LEADS TO CONTROL...

Gopffarth, Wilford Hugo

2012-06-07T23:59:59.000Z

49

Heater head for Stirling engine  

SciTech Connect (OSTI)

This patent describes a heater head for a Stirling engine comprising: a housing for enclosing the heater head with gas at a substantial elevated pressure; insulator means attached to the housing for insulating the heater head; inlet means attached to a regenerator in the housing for admission of relatively high pressure working fluid from the regenerator of a Stirling engine; a first annular heating wall in the housing attached to the inlet means for heating the working fluid; and, a second annular heating wall in the housing concentric with the first heating wall but of lesser diameters so that an annular space is formed between the first heating wall and the second heating wall for heating working fluid; and a third heating wall in the housing concentric with and smaller in diameter than the second heating wall forming the condensing area of a heat pipe between the second heating wall and the third heating wall.

White, M.A.; Emigh, S.G.

1987-06-09T23:59:59.000Z

50

Solar heater for swimming pools  

SciTech Connect (OSTI)

A solar heater for swimming pools is provided having one or more heating panels installable on a roof or the like and arranged to discharge into a pool equipped with an apron without need for disturbing or obstructing the apron. This is accomplished by the provision of an elevated bistable dumper adjacent the perimeter of the apron having a dispensing spout normally inclined upwardly but pivoting at intervals to discharge into the pool across the apron without obstructing it. Water to be heated is diverted from the pool filtering system to the solar heater via a pressure regulator and a solar responsive flow control.

Babcock, H.W.

1984-12-04T23:59:59.000Z

51

Storage Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Storage Water Heaters Storage Water Heaters Storage Water Heaters June 15, 2012 - 6:00pm Addthis Consider energy efficiency when selecting a conventional storage water heater to avoid paying more over its lifetime. | Photo courtesy of ©iStockphoto/JulNichols. Consider energy efficiency when selecting a conventional storage water heater to avoid paying more over its lifetime. | Photo courtesy of ©iStockphoto/JulNichols. Conventional storage water heaters remain the most popular type of water heating system for the home. Here you'll find basic information about how storage water heaters work; what criteria to use when selecting the right model; and some installation, maintenance, and safety tips. How They Work A single-family storage water heater offers a ready reservoir -- from 20 to

52

An internal winding high temperature heater  

Science Journals Connector (OSTI)

An internal winding high temperature heater ... General principles are outlined for the construction of compact heaters that are suitable for heating small containers or reaction vessels at constant temperature and up to about 1000 C. ...

A. J. Delbouille; E. G. Derouane

1973-01-01T23:59:59.000Z

53

Energy conversion by an electric space heater  

Science Journals Connector (OSTI)

By means of measuring the temperature of the air blown by an electric space heater one can show students that the air is heated at a rate approximately equal to the rated wattage of the heater.

Willem H. van den Berg

1998-01-01T23:59:59.000Z

54

CO2 Heat Pump Water Heater | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Heater CO2 Heat Pump Water Heater CO2 Heat Pump Water Heater Prototype
Credit: Oak Ridge National Lab CO2 Heat Pump Water Heater Prototype Credit: Oak Ridge National Lab...

55

Oil and Gas Air Heaters  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Heating technologies for energy efficiency Vol.III-1-2 Oil and Gas Air Heaters1 Guangxiao Kou Hanqing Wang Jiemin Zhou Doctoral Ph.D Ph.D Candidate Professor Professor Hunan University of Technology Hunan...

Kou, G.; Wang, H.; Zhou, J.

2006-01-01T23:59:59.000Z

56

Solar Swimming Pool Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Swimming Pool Heaters Swimming Pool Heaters Solar Swimming Pool Heaters May 29, 2012 - 6:03pm Addthis An example of a solar pool heater. An example of a solar pool heater. You can significantly reduce swimming pool heating costs by installing a solar pool heater. They're cost competitive with both gas and heat pump pool heaters, and they have very low annual operating costs. Actually, solar pool heating is the most cost-effective use of solar energy in many climates. How They Work Most solar pool heating systems include the following: A solar collector -- the device through which pool water is circulated to be heated by the sun A filter -- removes debris before water is pumped through the collector A pump -- circulates water through the filter and collector and back to the pool A flow control valve -- automatic or manual device that diverts pool

57

Solar Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heater Basics Solar Water Heater Basics Solar Water Heater Basics August 19, 2013 - 3:01pm Addthis Illustration of an active, closed loop solar water heater. A large, flat panel called a flat plate collector is connected to a tank called a solar storage/backup water heater by two pipes. One of these pipes runs through a cylindrical pump into the bottom of the tank, where it becomes a coil called a double-wall heat exchanger. This coil runs up through the tank and out again to the flat plate collector. Antifreeze fluid runs only through this collector loop. Two pipes run out the top of the water heater tank; one is a cold water supply into the tank, and the other sends hot water to the house. Solar water heaters use the sun's heat to provide hot water for a home or

58

Solar Swimming Pool Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Swimming Pool Heaters Solar Swimming Pool Heaters Solar Swimming Pool Heaters May 29, 2012 - 6:03pm Addthis An example of a solar pool heater. An example of a solar pool heater. You can significantly reduce swimming pool heating costs by installing a solar pool heater. They're cost competitive with both gas and heat pump pool heaters, and they have very low annual operating costs. Actually, solar pool heating is the most cost-effective use of solar energy in many climates. How They Work Most solar pool heating systems include the following: A solar collector -- the device through which pool water is circulated to be heated by the sun A filter -- removes debris before water is pumped through the collector A pump -- circulates water through the filter and collector and back to the pool

59

Welding shield for coupling heaters  

DOE Patents [OSTI]

Systems for coupling end portions of two elongated heater portions and methods of using such systems to treat a subsurface formation are described herein. A system may include a holding system configured to hold end portions of the two elongated heater portions so that the end portions are abutted together or located near each other; a shield for enclosing the end portions, and one or more inert gas inlets configured to provide at least one inert gas to flush the system with inert gas during welding of the end portions. The shield may be configured to inhibit oxidation during welding that joins the end portions together. The shield may include a hinged door that, when closed, is configured to at least partially isolate the interior of the shield from the atmosphere. The hinged door, when open, is configured to allow access to the interior of the shield.

Menotti, James Louis (Dickinson, TX)

2010-03-09T23:59:59.000Z

60

Regenerative Boiler Feedwater Heater Economics  

E-Print Network [OSTI]

REGENERATIVE BOILER FEEDWATER HEATER ECONOMICS William L. Viar, PE waterland, Viar & Associates, Inc. Wilmington, Delaware ABSTRACT The basic Rankine Vapor Cycle has been r,~peatedly modified to improve efficiency. Always, the objective....g., first and second laws of thermodynamics) have improved and contributed to the evolution. The demands for larger systems with higher performance have been persistent. Progress i ve changes in the app1icat ion of the fundamental Rankine cycle have...

Viar, W. L.

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Wood Dusts  

Science Journals Connector (OSTI)

Abstract The processing of wood is common in many types of work, and generates wood dust that has been associated with acute and chronic health effects. Workers exposed to wood dust may have adverse health effects such as upper and lower respiratory symptoms, decreased lung function, asthma, contact and allergic dermatitis, idiopathic pulmonary fibrosis, and sinonasal and nasopharyngeal cancer. This article is a revision of the previous edition article by Alan J. Weinrich and Paul Demers, volume 4, pp 464467, 2005, Elsevier Inc.

P.A. Demers; A.J. Weinrich

2014-01-01T23:59:59.000Z

62

Biomass Domestic Cooking Gasifier Stove for Use in Rural Areas of Developing Countries  

Science Journals Connector (OSTI)

An experimental Biomass Domestic Gasifier Cooking Stove (BDGCS) system is described here. A gasifier produces gas from biomass wastes such as...

Gao Xiansheng

1993-01-01T23:59:59.000Z

63

Performance improvement of direct- and indirect-fired heaters  

SciTech Connect (OSTI)

The operating performance of direct and indirect heaters is discussed, and principles and guidelines that can be applied to effect improvements in efficiency are presented. This paper also discusses the associated heater efficiencies and several useful operating techniques to approach the maximum, steady-state heater efficiency. The techniques presented apply to all types of direct-and indirect-fired heaters: salt bath heaters, propane vaporizers, heater/treaters, production heaters, and glycol and amine regenerators.

Sams, G.W.; Hunter, J.D.

1988-08-01T23:59:59.000Z

64

Adjusting alloy compositions for selected properties in temperature limited heaters  

DOE Patents [OSTI]

Heaters for treating a subsurface formation are described herein. Such heaters can be obtained by using the systems and methods described herein. The heater includes a heater section including iron, cobalt, and carbon. The heater section has a Curie temperature less than a phase transformation temperature. The Curie temperature is at least 740.degree. C. The heater section provides, when time varying current is applied to the heater section, an electrical resistance.

Brady; Michael Patrick (Oak Ridge, TN), Horton, Jr.; Joseph Arno (Oak Ridge, TN), Vitek; John Michael (Oak Ridge, TN)

2010-03-23T23:59:59.000Z

65

WoodChemistry Wood Degradation & Preservation  

E-Print Network [OSTI]

31 WoodChemistry Wood Degradation & Preservation Chemical Utilization of Wood Pulp & Paper and carbohydrates is of considerable interest in connection with a number of issues in wood chemistry, such as the reactions taking place during the formation of wood, the natural molecular weight distribution of lignin

Geldenhuys, Jaco

66

CO2 Conversion By Nano Heaters  

SciTech Connect (OSTI)

A graduate student named Oshadha Ranasingha created this animation on the research he performed on nano heaters while working at NETL.

None

2014-03-11T23:59:59.000Z

67

CO2 Heat Pump Water Heater  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

CO 2 Heat Pump Water Heater 2014 Building Technologies Office Peer Review Evaporator Kyle Gluesenkamp, gluesenkampk@ornl.gov Oak Ridge National Laboratory Project Summary Timeline:...

68

CO2 Conversion By Nano Heaters  

ScienceCinema (OSTI)

A graduate student named Oshadha Ranasingha created this animation on the research he performed on nano heaters while working at NETL.

None

2014-06-23T23:59:59.000Z

69

Parallel heater system for subsurface formations  

DOE Patents [OSTI]

A heating system for a subsurface formation is disclosed. The system includes a plurality of substantially horizontally oriented or inclined heater sections located in a hydrocarbon containing layer in the formation. At least a portion of two of the heater sections are substantially parallel to each other. The ends of at least two of the heater sections in the layer are electrically coupled to a substantially horizontal, or inclined, electrical conductor oriented substantially perpendicular to the ends of the at least two heater sections.

Harris, Christopher Kelvin (Houston, TX); Karanikas, John Michael (Houston, TX); Nguyen, Scott Vinh (Houston, TX)

2011-10-25T23:59:59.000Z

70

Combustion heater for oil shale  

DOE Patents [OSTI]

A combustion heater for oil shale heats particles of spent oil shale containing unburned char by burning the char. A delayed fall is produced by flowing the shale particles down through a stack of downwardly sloped overlapping baffles alternately extending from opposite sides of a vertical column. The delayed fall and flow reversal occurring in passing from each baffle to the next increase the residence time and increase the contact of the oil shale particles with combustion supporting gas flowed across the column to heat the shale to about 650 to 700/sup 0/C for use as a process heat source.

Mallon, R.; Walton, O.; Lewis, A.E.; Braun, R.

1983-09-21T23:59:59.000Z

71

Combustion heater for oil shale  

DOE Patents [OSTI]

A combustion heater for oil shale heats particles of spent oil shale containing unburned char by burning the char. A delayed fall is produced by flowing the shale particles down through a stack of downwardly sloped overlapping baffles alternately extending from opposite sides of a vertical column. The delayed fall and flow reversal occurring in passing from each baffle to the next increase the residence time and increase the contact of the oil shale particles with combustion supporting gas flowed across the column to heat the shale to about 650.degree.-700.degree. C. for use as a process heat source.

Mallon, Richard G. (Livermore, CA); Walton, Otis R. (Livermore, CA); Lewis, Arthur E. (Los Altos, CA); Braun, Robert L. (Livermore, CA)

1985-01-01T23:59:59.000Z

72

Coal use, stove improvement and pneumonia mortality in Xuanwei, China: a retrospective cohort study  

Science Journals Connector (OSTI)

...Apr 12-16, 2008; San Diego, CA Coal use, stove improvement and pneumonia mortality...Yunnan Province, China, unvented indoor coal burning is strongly associated with increased...and COPD risk. However, the impact of coal burning and stove improvement on risk of...

Min Shen; Robert Chapman; Roel Vermeulen; Tongzhang Zheng; Eric Chen; Xingzhou He; Aaron Blair; Qing Lan

2008-05-01T23:59:59.000Z

73

UBC Social Ecological Economic Development Studies (SEEDS) Student Report An Introduction into Induction and Natural Gas Stoves  

E-Print Network [OSTI]

into Induction and Natural Gas Stoves: A Triple Bottom Line Analysis for the new Student Union Building Jordan Ho of a project/report". #12;APSC 262 An Introduction Into Induction and Natural Gas Stoves A triple-bottom line, 2011 #12;Page 2 of 21 ABSTRACT This report compares the attributes of induction and natural gas stoves

74

A Study on the Failure of Industrial Electric Heater  

E-Print Network [OSTI]

The break down mechanism of a cylindrical electric heater is investigated by studying the uneven heating behavior of the heater by measuring the surface temperature variation of the heater when it is subjected to a boundary condition of constant...

Chyu, M. C.

75

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network [OSTI]

M.V. Lapsa. 2001. Residential Heat Pump Water Heater (HPWH)Calwell. 2005. Residential Heat Pump Water Heaters: EnergyA Specification for Residential Heat Pump Water Heaters

Franco, Victor

2011-01-01T23:59:59.000Z

76

Field Demonstration of High Efficiency Gas Heaters  

Broader source: Energy.gov [DOE]

For many buildings that do not require space cooling, non-centralized equipment such as unit heaters provide space heating to building occupants. Unit heaters are a major source of energy use nationally, accounting for nearly 18% of primary space heating energy use for commercial buildings, and most prominently appear in warehouses, distribution centers, loading docks, etc.

77

Subsurface connection methods for subsurface heaters  

DOE Patents [OSTI]

A system for heating a subsurface formation is described. The system includes a first elongated heater in a first opening in the formation. The first elongated heater includes an exposed metal section in a portion of the first opening. The portion is below a layer of the formation to be heated. The exposed metal section is exposed to the formation. A second elongated heater is in a second opening in the formation. The second opening connects to the first opening at or near the portion of the first opening below the layer to be heated. At least a portion of an exposed metal section of the second elongated heater is electrically coupled to at least a portion of the exposed metal section of the first elongated heater in the portion of the first opening below the layer to be heated.

Vinegar, Harold J. (Bellaire, TX); Bass, Ronald Marshall (Houston, TX); Kim, Dong Sub (Sugar Land, TX); Mason, Stanley Leroy (Allen, TX); Stegemeier, George Leo (Houston, TX); Keltner, Thomas Joseph (Spring, TX); Carl, Jr., Frederick Gordon (Houston, TX)

2010-12-28T23:59:59.000Z

78

Absorption Heat Pump Water Heater - 2013 Peer Review | Department...  

Energy Savers [EERE]

Absorption Heat Pump Water Heater - 2013 Peer Review Absorption Heat Pump Water Heater - 2013 Peer Review Emerging Technologies Project for the 2013 Building Technologies Office's...

79

Residential Absorption Heat Pump Water Heater | Department of...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Heat Pump Water Heater Residential Absorption Heat Pump Water Heater Photo credit: Oak Ridge National Lab Photo credit: Oak Ridge National Lab Diagram of absorption heat...

80

Ex Parte Memorandum on Grid-Enabled Water Heaters | Department...  

Energy Savers [EERE]

with DOE representatives regarding water heater standards and thermal storage and demand response programs. DOE exparte memo100213 Grid-EnabledWaterHeaterAmendment More...

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Covered Product Category: Residential Heat Pump Water Heaters...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Residential Heat Pump Water Heaters Covered Product Category: Residential Heat Pump Water Heaters The Federal Energy Management Program (FEMP) provides acquisition guidance and...

82

Efficient Residential Water Heaters Webinar | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Weatherization Assistance Program Pilot Projects Efficient Residential Water Heaters Webinar Efficient Residential Water Heaters Webinar On Feb. 22, 2011, Jerone Gagliano,...

83

Covered Product Category: Residential Gas Storage Water Heaters...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Storage Water Heaters Covered Product Category: Residential Gas Storage Water Heaters The Federal Energy Management Program (FEMP) provides acquisition guidance for gas storage...

84

Energy Cost Calculator for Electric and Gas Water Heaters | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Electric and Gas Water Heaters Energy Cost Calculator for Electric and Gas Water Heaters Vary equipment size, energy cost, hours of operation, and or efficiency level. INPUT...

85

DOE Publishes Notice of Proposed Rulemaking for Residential Water Heater and Certain Commercial Water Heater Test Procedures  

Broader source: Energy.gov [DOE]

The Department of Energy has published a notice of proposed rulemaking regarding test procedures for residential water heaters and certain commercial water heaters.

86

Wood biology We present investigations of wood  

E-Print Network [OSTI]

Wood biology We present investigations of wood formation which started in 1999. Samples for investigations are taken from living trees. Processes of wood formation are affected by different factors like temperature and precipitation. #12;We use light microscopy to study cell wall formation in the wood. Double

Cufar, Katarina

87

Wood Curriculum vitae 1 ERIC MATTHEW WOOD  

E-Print Network [OSTI]

Wood ­ Curriculum vitae 1 ERIC MATTHEW WOOD Spatial Analysis for Conservation and Department/17/2014 Postdoctoral Research Associate, University of Wisconsin-Madison PUBLICATIONS Wood, E. M., A. M. Pidgeon, V. C community structure in U.S protected areas. Ecological Applications in press Wood, E. M., and A. M. Pidgeon

Mladenoff, David

88

FRACTURE TOUGHNESS OF WOOD AND WOOD COMPOSITES  

E-Print Network [OSTI]

FRACTURE TOUGHNESS OF WOOD AND WOOD COMPOSITES DURING CRACK PROPAGATION Noah Matsumoto Structural, USA * Corresponding author: John.Nairn@oregonstate.edu SWST member #12;Fracture Toughness of Wood and Wood Composites During Crack Propagation ABSTRACT The mode I fracture toughness as a function of crack

Nairn, John A.

89

Tankless or Demand-Type Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tankless or Demand-Type Water Heaters Tankless or Demand-Type Water Heaters Tankless or Demand-Type Water Heaters May 2, 2012 - 6:47pm Addthis Diagram of a tankless water heater. Diagram of a tankless water heater. How does it work? Tankless water heaters deliver hot water as it is needed, eliminating the need for storage tanks. Tankless water heaters, also known as demand-type or instantaneous water heaters, provide hot water only as it is needed. They don't produce the standby energy losses associated with storage water heaters, which can save you money. Here you'll find basic information about how they work, whether a tankless water heater might be right for your home, and what criteria to use when selecting the right model. Check out the Energy Saver 101: Water Heating infographic to learn if a tankless water heater is right for you.

90

Quantifying Stove Emissions Related to Different Use Patterns for the Silver-mini  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Quantifying Stove Emissions Related to Quantifying Stove Emissions Related to Different Use Patterns for the Silver-mini (Small Turkish) Space Heating Stove Randy Maddalena, Melissa Lunden, Daniel Wilson, Cristina Ceballos, Thomas Kirchstetter, Jonathan Slack, Larry Dale Environmental Energy Technologies Division Indoor Environment Group Lawrence Berkeley National Laboratory Berkeley, CA 94720 August 2012 This work was supported by the Millennium Challenge Corporation, USA and by the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. LBNL-6319E Disclaimer This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither

91

TREES, WOODS AND FORESTS  

E-Print Network [OSTI]

SCOTLAND'S TREES, WOODS AND FORESTS #12;2 SCOTLAND'S TREES, WOODS AND FORESTS2 #12;SCOTLAND'S TREES, WOODS AND FORESTS 3 CONTENTS CHAPTER 1 SCOTLAND'S FORESTS CHAPTER 2 FORESTS FOR PEOPLE CHAPTER 3 FORESTS SCOTLAND'S TREES, WOODS AND FORESTS #12;4 SCOTLAND'S TREES, WOODS AND FORESTS4 This booklet is written

92

Tankless Water Heaters: Do They Really Work?  

Broader source: Energy.gov (indexed) [DOE]

Tankless Water Heaters: Do They Tankless Water Heaters: Do They Really Work? Center for Energy and Environment, NorthernSTAR, Ben Schoenbauer Context * Domestic Water Heating is the next big residential energy in efficiency. - Space heating loads are being reduced - Largest peak load in almost all homes is water heating - Annual water heating load is larger than annual space heating load in many homes - Most DHW equipment is inefficiency 50-60% Technical Approach * TWHs and condensing TWHs have significant energy savings potential - Do these ratings relate to real world performance? - How do TWHs compare to standard water heaters? - What performance/install issues do they have? * 10 home 26 water heater alternating mode field study was conducted Recommended Guidance * In situations where economics are

93

Solar Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heaters Solar Water Heaters Solar Water Heaters May 7, 2012 - 9:52am Addthis Solar water heaters -- also called solar domestic hot water systems -- can be a cost-effective way to generate hot water for your home. They can be used in any climate, and the fuel they use -- sunshine -- is free. How They Work Solar water heating systems include storage tanks and solar collectors. There are two types of solar water heating systems: active, which have circulating pumps and controls, and passive, which don't. Active Solar Water Heating Systems There are two types of active solar water heating systems: Direct circulation systems Pumps circulate household water through the collectors and into the home. They work well in climates where it rarely freezes. Indirect circulation systems

94

Solar water heaters | Open Energy Information  

Open Energy Info (EERE)

heaters heaters Jump to: navigation, search (The following text is derived from the United States Department of Energy's description of Solar Water Heating technology.)[1] Solar Water Heater One of the most cost-effective ways to include renewable technologies into a building is by incorporating solar hot water. A typical residential solar water-heating system reduces the need for conventional water heating by about two-thirds. It minimizes the expense of electricity or fossil fuel to heat the water and reduces the associated environmental impacts. Solar Water Heating for Buildings Most solar water-heating systems for buildings have two main parts: (1) a solar collector and (2) a storage tank. The most common collector used in solar hot water systems is the flat-plate collector. Solar water heaters use the sun to heat either water

95

Heater head for a Stirling engine  

SciTech Connect (OSTI)

A heater head is described for a compound Stirling engine modules, each including a displacer cylinder coaxially aligned with the displacer cylinder of the other of the engine modules, a displacer piston mounted for reciprocation in the displacer cylinder.

Darooka, D.K.

1988-09-06T23:59:59.000Z

96

Arnold Schwarzenegger WATER HEATERS AND HOT WATER  

E-Print Network [OSTI]

Arnold Schwarzenegger Governor WATER HEATERS AND HOT WATER DISTRIBUTION SYSTEMS;#12;Appendices Appendix A. Multifamily Water Heating Construction Practices, Pricing and Availability Survey Report Appendix B. Multifamily Water Heating Controls Performance Field Report Appendix C. Pipe

97

Heat Pump Water Heaters Demonstration Project  

Broader source: Energy.gov (indexed) [DOE]

Heat Pump Water Heaters Heat Pump Water Heaters Demonstration Project Building America Stakeholder Meeting Ron Domitrovic Ammi Amarnath 3/1/2012 Austin, TX 2 © 2011 Electric Power Research Institute, Inc. All rights reserved. HPWH Field Demonstration: Research Objectives * Assess heat pump water heater technology by measuring efficiency. * Provide credible data on the performance and reliability of heat pump water heaters. * Assess user satisfaction in a residential setting. 3 © 2011 Electric Power Research Institute, Inc. All rights reserved. Demonstration Host Utilities Target: 40 Units per Utility Installed and Potential Sites by Climate Zone Source: Department of Energy (DOE), Building America climate regions 4 © 2011 Electric Power Research Institute, Inc. All rights reserved. Installation Locations-Southern Company Region

98

Varying properties along lengths of temperature limited heaters  

DOE Patents [OSTI]

A system for heating a subsurface formation is described. The system includes an elongated heater in an opening in the formation. The elongated heater includes two or more portions along the length of the heater that have different power outputs. At least one portion of the elongated heater includes at least one temperature limited portion with at least one selected temperature at which the portion provides a reduced heat output. The heater is configured to provide heat to the formation with the different power outputs. The heater is configured so that the heater heats one or more portions of the formation at one or more selected heating rates.

Vinegar, Harold J. (Bellaire, TX); Xie, Xueying (Houston, TX); Miller, David Scott (Katy, TX); Ginestra, Jean Charles (Richmond, TX)

2011-07-26T23:59:59.000Z

99

Phase change material storage heater  

DOE Patents [OSTI]

A storage heater for storing heat and for heating a fluid, such as water, has an enclosure defining a chamber therein. The chamber has a lower portion and an upper portion with a heating element being disposed within the enclosure. A tube through which the fluid flows has an inlet and an outlet, both being disposed outside of the enclosure, and has a portion interconnecting the inlet and the outlet that passes through the enclosure. A densely packed bed of phase change material pellets is disposed within the enclosure and is surrounded by a viscous liquid, such as propylene glycol. The viscous liquid is in thermal communication with the heating element, the phase change material pellets, and the tube and transfers heat from the heating element to the pellets and from the pellets to the tube. The viscous fluid has a viscosity so that the frictional pressure drop of the fluid in contact with the phase change material pellets substantially reduces vertical thermal convection in the fluid. As the fluid flows through the tube heat is transferred from the viscous liquid to the fluid flowing through the tube, thereby heating the fluid.

Goswami, D. Yogi (Gainesville, FL); Hsieh, Chung K. (Gainesville, FL); Jotshi, Chand K. (Gainesville, FL); Klausner, James F. (Gainesville, FL)

1997-01-01T23:59:59.000Z

100

Diesel particulate filter with zoned resistive heater  

DOE Patents [OSTI]

A diesel particulate filter assembly comprises a diesel particulate filter (DPF) and a heater assembly. The DPF filters a particulate from exhaust produced by an engine. The heater assembly has a first metallic layer that is applied to the DPF, a resistive layer that is applied to the first metallic layer, and a second metallic layer that is applied to the resistive layer. The second metallic layer is etched to form a plurality of zones.

Gonze, Eugene V [Pinckney, MI

2011-03-08T23:59:59.000Z

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Reducing NOx in Fired Heaters and Boilers  

E-Print Network [OSTI]

-6, 2000 Reducing NOx in Fired Heaters Air Pollution Control and Boilers Keeping the environment clean Presented by Ashutosh Garg Furnace Improvements Low cost solutions for fired heaters Trace compounds ? Nitric oxides ? Carbon monoxide ? Sulfur... it is essential to estimate accurately baseline NOx emissions. ? This will establish each units current compliance status. ? Emissions ? Current excess air level ? Carbon monoxide ? Combustibles ? NOx corrected to 3% 02 314 ESL-IE-00-04-46 Proceedings...

Garg, A.

102

Sizing a New Water Heater | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Sizing a New Water Heater Sizing a New Water Heater Sizing a New Water Heater May 29, 2012 - 7:16pm Addthis Is your water heater the right size for you house? | Photo credit ENERGY STAR® Is your water heater the right size for you house? | Photo credit ENERGY STAR® A properly sized water heater will meet your household's hot water needs while operating more efficiently. Therefore, before purchasing a water heater, make sure it's the correct size. Here you'll find information about how to size these systems: Tankless or demand-type water heaters Solar water heating system Storage and heat pump (with tank) water heaters. For sizing combination water and space heating systems -- including some heat pump systems, and tankless coil and indirect water heaters -- consult a qualified contractor.

103

Selecting a New Water Heater | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Selecting a New Water Heater Selecting a New Water Heater Selecting a New Water Heater August 29, 2012 - 7:30pm Addthis Water heater testing facility at Oak Ridge National Laboratory. Water heater testing facility at Oak Ridge National Laboratory. When selecting a new water heater for your home, choose a water heating system that will not only provide enough hot water but also that will do so energy efficiently, saving you money. This includes considering the different types of water heaters available and determining the right size and fuel source for your home. Check out the Energy Saver 101: Water Heating infographic to learn more about the different types of water heaters and how to select the right model for your home. Types of Water Heaters It's a good idea to know the different types of water heaters available

104

Elmira Stove Works: Proposed Penalty (2011-CE-1407) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Proposed Penalty (2011-CE-1407) Proposed Penalty (2011-CE-1407) Elmira Stove Works: Proposed Penalty (2011-CE-1407) April 22, 2011 DOE alleged in a Notice of Proposed Civil Penalty that Elmira Stove Works failed to certify refrigerator-freezers as compliant with the energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. Elmira Stove Works: Proposed Penalty (2011-CE-1407) More Documents & Publications Elmira Stove Works: Order (2011-CE-1407) Living Direct: Proposed Penalty (2011-CE-1904)

105

Tankless Coil and Indirect Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tankless Coil and Indirect Water Heaters Tankless Coil and Indirect Water Heaters Tankless Coil and Indirect Water Heaters May 16, 2013 - 7:21pm Addthis An indirect water heater. An indirect water heater. How does it work? Tankless coil and indirect water heaters use your home's heating system to heat water. Tankless coil and indirect water heaters use a home's space heating system to heat water. They're part of what's called integrated or combination water and space heating systems. How They Work A tankless coil water heater provides hot water on demand without a tank. When a hot water faucet is turned on, water is heated as it flows through a heating coil or heat exchanger installed in a main furnace or boiler. Tankless coil water heaters are most efficient during cold months when the heating system is used regularly but can be an inefficient choice for many

106

Tankless Coil and Indirect Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Coil and Indirect Water Heater Basics Coil and Indirect Water Heater Basics Tankless Coil and Indirect Water Heater Basics August 19, 2013 - 3:03pm Addthis Illustration of a tankless coil water heater. The heater is box-shaped, and has two pipes sticking out one end: one a cold water inlet, and one a hot water outlet. These pipes lead into the heater to a cylindrical coil called a heat exchanger. Long tubes surrounding the heat exchanger are labeled the heated water jacket. At the bottom of the box is a row of small flames, called the boiler heat source. Tankless coil and indirect water heaters use a home or building's space heating system to heat water as part of an integrated or combination water and space heating system. How Tankless Coil and Indirect Water Heaters Work A tankless coil water heater uses a heating coil or heat exchanger

107

An International Survey of Electric Storage Tank Water Heater Efficiency and Standards  

E-Print Network [OSTI]

Survey of Electric Storage Tank Water Heater Efficiency andSurvey of Electric Storage Tank Water Heater Efficiency andby electric resistance storage tank water heaters (geysers),

Johnson, Alissa

2013-01-01T23:59:59.000Z

108

Temperature limited heaters using phase transformation of ferromagnetic material  

DOE Patents [OSTI]

Systems, methods, and heaters for treating a subsurface formation are described herein. Systems and methods for making heaters are described herein. At least one heater includes a ferromagnetic conductor and an electrical conductor. The electrical conductor is electrically coupled to the ferromagnetic conductor. The heater provides a first amount of heat at a lower temperature. The heater may provide a second reduced amount of heat when the heater reaches a selected temperature, or enters a selected temperature range, at which the ferromagnetic conductor undergoes a phase transformation.

Vitek, John Michael [Oak Ridge, TN; Brady, Michael Patrick [Oak Ridge, TN

2009-10-06T23:59:59.000Z

109

MHD oxidant intermediate temperature ceramic heater study. Final report  

SciTech Connect (OSTI)

The use of three types of directly fired ceramic heaters for preheating oxygen enriched air to an intermediate temperature of 1144K was investigated. The three types of ceramic heaters are: (1) a fixed bed, periodic flow ceramic brick regenerative heater (2) a ceramic pebble regenerative heater. The heater design, performance and operating characteristics under conditions in which the particulate matter is not solidified are evaluated. A comparison and overall evaluation of the three types of ceramic heaters and temperature range determination at which the particulate matter in the MHD exhaust gas is estimated to be a dry powder are presented.

Carlson, A.W.; Chait, I.L.; Saari, D.P.; Marksberry, C.L.

1981-09-01T23:59:59.000Z

110

Wood Quality: The Effects  

E-Print Network [OSTI]

Wood Quality: The Effects of Planting Density and Thinning Eini C. Lowell PNW Research Station wood quality? By volume, characteristic, product? #12;http://jilldenton.files.wordpress.com/2007, faster #12;What is it that defines wood quality?What is it that defines wood quality? Density: earlywood

111

Wood Resources International  

E-Print Network [OSTI]

Wood Resources International Wood Raw Material Consumption on the Rise Despite Weak Global Economy UNECE Timber Committee Meeting October 7-8, 2003 Geneva, Switzerland Håkan Ekström Wood Resources International #12;Wood Resources International Outline · Roundwood Removals · Roundwood Consumption · Raw

112

Solar water heaters | Open Energy Information  

Open Energy Info (EERE)

water heaters water heaters (Redirected from - Solar Hot Water) Jump to: navigation, search (The following text is derived from the United States Department of Energy's description of Solar Water Heating technology.)[1] Solar Water Heater One of the most cost-effective ways to include renewable technologies into a building is by incorporating solar hot water. A typical residential solar water-heating system reduces the need for conventional water heating by about two-thirds. It minimizes the expense of electricity or fossil fuel to heat the water and reduces the associated environmental impacts. Solar Water Heating for Buildings Most solar water-heating systems for buildings have two main parts: (1) a solar collector and (2) a storage tank. The most common collector used in solar hot water systems is the

113

Combined Systems with Tankless Water Heaters  

Broader source: Energy.gov (indexed) [DOE]

Combined Systems with Tankless Water Heaters Combined Systems with Tankless Water Heaters Armin Rudd Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas 2 Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas More builder's wanting to use gas-fired tankless water heaters, and with solar pre-heat  Endless hot water  Helps HERS Index  Space saving 2 3 Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas Problem with elevated TWH inlet temperature 60 70 80 90 100 110 120 130 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 Maximum Inlet Temperature (F) DHW flow rate (gpm) Maximum TWH inlet temperature to stay below 125 F delivered temperature, with 15 kBtu/h minimum firing rate Typical shower temperature 4 Residential Energy Efficiency Stakeholder Meeting

114

Solar Water Heater Rebate | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heater Rebate Solar Water Heater Rebate Solar Water Heater Rebate < Back Eligibility Commercial Fed. Government Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Hawaii Program Type State Rebate Program Rebate Amount Residential Solar Water Heating: $1,000 upfront, or Residential Solar Water Heating Interest Loan Buy-Down: $1,000 Residential Solar Attic Fans: $50 Commercial: $250 per 12,000 Btu/hr derated capacity Provider Hawaii Energy Hawaii Energy, a third-party administered public benefits fund, provides incentives for energy efficiency and conservation to customers of the Hawaiian Electric Company (HECO) and its subsidiaries, Maui Electric Company (MECO) and Hawaii Electric Light Company (HELCO). This incentive is available for installations on the islands of Oahu, Hawaii, Maui, Lanai and

115

Building Technologies Office: HVAC and Water Heater Field Tests Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

HVAC and Water Heater HVAC and Water Heater Field Tests Research Project to someone by E-mail Share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Facebook Tweet about Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Twitter Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Google Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Delicious Rank Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Digg Find More places to share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research

116

Heat Pump Water Heater using Solid-State Energy Converters |...  

Energy Savers [EERE]

Heat Pump Water Heater using Solid-State Energy Converters Heat Pump Water Heater using Solid-State Energy Converters Sheetak will work on developing a full scale prototype of its...

117

Design, Stress Analysis and Operating Experience in Feedwater Heaters  

E-Print Network [OSTI]

The performance of feedwater heaters has a direct bearing on the thermal efficiency of the plant. A typical feedwater heater may have three distinct regions of heat transfer, namely desuperheating, condensing and subcooling zones. The design...

Singh, K. P.; Libs, T.

1980-01-01T23:59:59.000Z

118

TVA Partner Utilities- Energy Right Water Heater Program  

Broader source: Energy.gov [DOE]

The TVA energy right Water Heater Plan promotes the installation of high efficiency water heaters in homes and small businesses. TVA provides a $50 incentive to local power companies for each...

119

TVA Partner Utilities- Energy Right Water Heater Program  

Broader source: Energy.gov [DOE]

The Tennessee Valley Authority (TVA) energy right Water Heater Plan promotes the installation of high efficiency water heaters in homes and small businesses. TVA provides a $50 incentive to local...

120

Making Water Heaters More Efficient | GE Global Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Water Heaters More Efficient Making Water Heaters More Efficient Jigar Shah 2013.11.13 As children, many of us grow up wanting to make some sort of lasting positive impact on...

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Vertical feed stick wood fuel burning furnace system  

DOE Patents [OSTI]

A new and improved stove or furnace for efficient combustion of wood fuel including a vertical feed combustion chamber for receiving and supporting wood fuel in a vertical attitude or stack, a major upper portion of the combustion chamber column comprising a water jacket for coupling to a source of water or heat transfer fluid and for convection circulation of the fluid for confining the locus of wood fuel combustion to the bottom of the vertical gravity feed combustion chamber. A flue gas propagation delay channel extending from the laterally directed draft outlet affords delayed travel time in a high temperature environment to assure substantially complete combustion of the gaseous products of wood burning with forced air as an actively induced draft draws the fuel gas and air mixture laterally through the combustion and high temperature zone. Active sources of forced air and induced draft are included, multiple use and circuit couplings for the recovered heat, and construction features in the refractory material substructure and metal component superstructure.

Hill, Richard C. (Orono, ME)

1984-01-01T23:59:59.000Z

122

Vertical feed stick wood fuel burning furnace system  

DOE Patents [OSTI]

A stove or furnace for efficient combustion of wood fuel includes a vertical feed combustion chamber (15) for receiving and supporting wood fuel in a vertical attitude or stack. A major upper portion of the combustion chamber column comprises a water jacket (14) for coupling to a source of water or heat transfer fluid for convection circulation of the fluid. The locus (31) of wood fuel combustion is thereby confined to the refractory base of the combustion chamber. A flue gas propagation delay channel (34) extending laterally from the base of the chamber affords delayed travel time in a high temperature refractory environment sufficient to assure substantially complete combustion of the gaseous products of wood burning with forced air prior to extraction of heat in heat exchanger (16). Induced draft draws the fuel gas and air mixture laterally through the combustion chamber and refractory high temperature zone to the heat exchanger and flue. Also included are active sources of forced air and induced draft, multiple circuit couplings for the recovered heat, and construction features in the refractory material substructure and metal component superstructure.

Hill, Richard C. (Orono, ME)

1982-01-01T23:59:59.000Z

123

NREL Evaluates Performance of Heat Pump Water Heaters (Fact Sheet)  

SciTech Connect (OSTI)

NREL evaluates energy savings potential of heat pump water heaters in homes throughout all U.S. climate zones.

Not Available

2012-02-01T23:59:59.000Z

124

Wood Products 201213 Student Handbook  

E-Print Network [OSTI]

Wood Products 201213 Student Handbook Ecosystem Science and Management College ........................................................................................................................... 2 Wood Products Undergraduate Program ...................................................................................................................................................... 3 Careers for Wood Products Majors

Boyer, Elizabeth W.

125

Covered Product Category: Commercial Gas Water Heaters  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including commercial gas water heaters, which are covered by the ENERGY STAR program. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

126

Biomass Stove Pollution Sam Beck ATOC-3500 Biomass energy accounts for about 15% of the world's primary energy consumption and  

E-Print Network [OSTI]

Biomass Stove Pollution Sam Beck ATOC-3500 Biomass energy accounts for about 15% of the world. Furthermore, biomass often accounts for more than 90% of the total rural energy supplies in developing countries. The traditional stoves in developing countries waste a lot of biomass, mainly because

Toohey, Darin W.

127

Patterns of stove usage after introduction of an advanced cookstove: the long-term application of household sensors  

Science Journals Connector (OSTI)

Household air pollution generated from solid fuel use for cooking is one of the leading risk factors for ill-health globally. ... However, household usage of these stoves and resulting changes in usage of traditional polluting stoves is not well characterized. ...

Ajay Pillarisetti; Mayur Vaswani; Darby Jack; Kalpana Balakrishnan; Michael N. Bates; Narendra K. Arora; Kirk R. Smith

2014-11-12T23:59:59.000Z

128

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

E-Print Network [OSTI]

Diagram 1: A Typical Tank Water Heater Source: http://to-unit comparisons of tank versus tankless water heaters.Energy Use MJ/(unit*year) Tank Tankless MJ/(unit*year) Tank

Lu, Alison

2011-01-01T23:59:59.000Z

129

Efficient Cook Stoves for Darfur : Future Technologies : From the Lab to  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Efficient Cook Stoves for Darfur Efficient Cook Stoves for Darfur From the Lab to the Marketplace Ten Years Later, Energy Efficient Technologies from Research at the Lawrence Berkeley National Laboratory Berkeley Lab logo (left) with six rows of gray dots transitioning to a line art drawing of a cityscape and residential houses. Efficient Cook Stoves for Darfur Beginning in 2003, hundreds of thousands of people have been killed, and another 2.2 million have become internal refugees in the Darfur region of Sudan. Although the refugees are relatively safe inside the refugee camps, they risk murder and rape when they leave to fetch firewood. To reduce the amount of firewood the refugees need, Berkeley Lab scientist Ashok Gadgil modified an existing cookstove design to create one that is 75% more

130

Introduction Mich ael Wood  

E-Print Network [OSTI]

Introduction Mich ael Wood Italo Calvino was discreet about his life and the lives of others or mechanical means without prior written permission of the publisher. #12;viii michael wood notion with great

Rowley, Clarence W.

131

WOOD STREET METERED LOT  

E-Print Network [OSTI]

LOT E1 LOT O WOOD STREET METERED LOT LOT W5 LOT C4 LOT B4 LOT L LOT M MARSHFIELDAVENUE PAULINASTREET Clinical Sciences Building UI Hospital Wood Street Station Clinical Sciences North Grand Grounds Garden

Dai, Yang

132

An Overview of the New Residential Water Heater Efficiency Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

An Overview of the New Residential Water Heater Efficiency Standards An Overview of the New Residential Water Heater Efficiency Standards Speaker(s): Alex Lekov Date: April 26, 2010 - 12:00pm Location: 90-3122 DOE issued new standards for residential water heaters last month that will save an estimated 2.6 quads of energy over 30 years. For most product sizes sold, the new standards can be met with modest changes, such as adding more insulation to today's conventional tank-style water heaters. For the most common size electric water heater (50 gallons), the standards will save 4 percent, while for the most common size gas water heater (40 gallons), the new standards will save 3 percent. However, for the biggest products (those with over 55 gallons in storage capacity, which is about 9% and 4% of the electric and gas storage water heater markets, respectively), the new

133

TVA Partner Utilities - Energy Right' Water Heater Program | Department of  

Broader source: Energy.gov (indexed) [DOE]

Right' Water Heater Program Right&#039; Water Heater Program TVA Partner Utilities - Energy Right' Water Heater Program < Back Eligibility Installer/Contractor Residential Utility Savings Category Appliances & Electronics Water Heating Maximum Rebate Member utility water heater rebate programs can range from $25 to total cost. Program Info State Mississippi Program Type Utility Rebate Program Rebate Amount Energy Efficient Water Heater: $50 from TVA Provider Tennessee Valley Authority The TVA energy right Water Heater Plan promotes the installation of high efficiency water heaters in homes and small businesses. TVA provides a $50 incentive to local power companies for each installation. Power Companies may pass these incentives on to customers. Customers should contact their local power company to see what programs are

134

Burbank Water and Power - Solar Water Heater Rebate Program (California) |  

Broader source: Energy.gov (indexed) [DOE]

Burbank Water and Power - Solar Water Heater Rebate Program Burbank Water and Power - Solar Water Heater Rebate Program (California) Burbank Water and Power - Solar Water Heater Rebate Program (California) < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State California Program Type Utility Rebate Program Rebate Amount $1,500 Provider Rebates Burbank Water and Power is providing incentives for the purchase of solar water heaters. Incentives are only available to residential customers with electric water heaters. There is a limit of one solar water heater per year per property. Applicants must provide access to their residence for a pre-inspection to verify the existing use of an electric water heater. Customers must comply with all code and permit requirements. More

135

Advanced refinery process heater. Annual report, October 1983-September 1984  

SciTech Connect (OSTI)

Activity during the first year of this project has focused on the conceptual design of the prototype heater and on the development of a custom-designed Pyrocore ceramic fiber burner for the heater. Three different concepts for the prototype heater have been produced, one of them modeled after a vertical cylindrical design and the other two resembling box-type heaters. All three concepts take advantage of the Pyrocore burner's flameless characteristic to make the heater more compact. Concerning the development of the burners, two different geometries were considered. Subscale prototypes of each type of burner were fabricated and tested. The more successful burners used actively-cooled edges to maintain the integrity of the gas-tight seals. Work on this project in the second year will include the design and fabrication of the 10 MMBtu/hr prototype heater, using the most feasible heater and burner designs developed during the first year.

Schreiber, R.J.; Gotterba, J.A.; Minden, A.C.

1984-10-01T23:59:59.000Z

136

CURRICULUM VITAE Robert Wood  

E-Print Network [OSTI]

CURRICULUM VITAE Robert Wood Assistant Professor Atmospheric Sciences, Box 351640, University. Publications [1] Wood, R., I. M. Stromberg, P. R. Jonas and C. S. Mill, 1997: Analysis of an air motion system on a light aircraft for boundary layer research. J. Atmos. Oceanic Technol., 14, 960-968. [2] Wood, R., D. W

Wood, Robert

137

Wood Durability Service & Reliability  

E-Print Network [OSTI]

Wood Durability Laboratory Service & Reliability Equipment & Facilities Field sites for AWPA E-7 (mold) tests. Wood weathering facilities. Lab-scale pressure treating cylin- ders. X-ray preservative analyzer (Oxford Twin-X). State-of-the-art facilities for wood and plastics composites manufacturing

138

The Friction of Wood  

Science Journals Connector (OSTI)

...1958 research-article The Friction of Wood D. Atack D. Tabor Earlier work, especially...following paper shows that the friction of wood may be explained in a similar way, that...The friction was studied between balsam wood (Abies balsamea) and surfaces of steel...

1958-01-01T23:59:59.000Z

139

Condensing Hybrid Water Heater Monitoring Field Evaluation  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Condensing Hybrid Water Heater Condensing Hybrid Water Heater Monitoring Field Evaluation Jeff Maguire, Lieko Earle, and Chuck Booten National Renewable Energy Laboratory C.E. Hancock Mountain Energy Partnership Produced under direction of the Sacramento Municipal Utilities District by the National Renewable Energy Laboratory (NREL) under Interagency Agreement CRD-05-168 and Task No WR49.3000. Technical Report NREL/TP-5500-52234 October 2011 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308

140

AWSWAH - the heat pipe solar water heater  

SciTech Connect (OSTI)

An all weather heat pipe solar water heater (AWSWAH) comprising a collector of 4 m/sup 2/ (43 ft/sup 2/) and a low profile water tank of 160 liters (42 gal.) was developed. A single heat pipe consisting of 30 risers and two manifolds in the evaporator and a spiral condenser was incorporated into the AWSWAH. Condensate metering was done by synthetic fiber wicks. The AWSWAH was tested alongside two conventional solar water heaters of identical dimensions, an open loop system and a closed loop system. It was found that the AWSWAH was an average of 50% more effective than the open system in the temperature range 30-90 /sup 0/C (86-194 /sup 0/F). The closed loop system was the least efficient of the three systems.

Akyurt, M.

1986-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Cryostat including heater to heat a target  

DOE Patents [OSTI]

A cryostat is provided which comprises a vacuum vessel; a target disposed within the vacuum vessel; a heat sink disposed within the vacuum vessel for absorbing heat from the detector; a cooling mechanism for cooling the heat sink; a cryoabsorption mechanism for cryoabsorbing residual gas within the vacuum vessel; and a heater for maintaining the target above a temperature at which the residual gas is cryoabsorbed in the course of cryoabsorption of the residual gas by the cryoabsorption mechanism. 2 figs.

Pehl, R.H.; Madden, N.W.; Malone, D.F.

1990-09-11T23:59:59.000Z

142

STEO October 2012 - wood  

U.S. Energy Information Administration (EIA) Indexed Site

More U.S. households burning wood this winter to stay warm, More U.S. households burning wood this winter to stay warm, reversing two-decade decline Burning wood as the primary heating source in U.S. households has risen over the last 10 years, reversing the decline seen in the 1980s and 1990s. About 2.6 million households out of 115 million will rely on wood as the main way to warm their homes this winter. That's up 3 percent from last year, according to the U.S. Energy Information Administration's new winter fuels forecast. The West will have the most households using wood as their primary space heating fuel, followed by the Midwest, South and Northeast regions of the United States. Wood is also the second most common backup fuel, after electricity, that households across the U.S. use as a supplemental heating source. Almost half of all rural households use wood this

143

Carbon Dioxide Heat Pump Water Heater Research Project | Department of  

Broader source: Energy.gov (indexed) [DOE]

Emerging Technologies » Carbon Dioxide Heat Pump Water Heater Emerging Technologies » Carbon Dioxide Heat Pump Water Heater Research Project Carbon Dioxide Heat Pump Water Heater Research Project The U.S. Department of Energy is currently conducting research into carbon dioxide (CO2) heat pump water heaters. This project will employ innovative techniques to adapt water heating technology to meet U.S. market requirements, including specifications, cost, and performance targets. Carbon dioxide is a refrigerant with a global warming potential (GWP) of 1. The CO2 heat pump water heater research seeks to develop an improved life cycle climate performance compared to conventional refrigerants. For example, R134a, another type of refrigerant, has a GWP of 1,300. Project Description This project seeks to develop a CO2-based heat pump water heater (HPWH)

144

Aiken Electric Cooperative Inc - Residential Water Heater Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

Aiken Electric Cooperative Inc - Residential Water Heater Rebate Aiken Electric Cooperative Inc - Residential Water Heater Rebate Program Aiken Electric Cooperative Inc - Residential Water Heater Rebate Program < Back Eligibility Residential Savings Category Appliances & Electronics Water Heating Program Info State South Carolina Program Type Utility Rebate Program Rebate Amount Free high efficiency water Heater; $200 installation fee Water heater and timer with normal installation: $2.50 credit for 10 years Timer only: $200 cash payment and $2.50 credit for 10 years New construction contract home: $250 Provider Aiken Electric Cooperative Aiken Electric Cooperative offers residential members rebates for installing high-efficiency electric water heaters and/or timers in their homes. Customers have four rebate options:

145

Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program  

Broader source: Energy.gov (indexed) [DOE]

Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program (Georgia) Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program (Georgia) < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Georgia Program Type Utility Rebate Program Rebate Amount Existing Homes Solar Water Heater: $750 New Homes Solar Water Heater: $1,250 - $1,500 Provider Coweta-Fayette Electric Membership Corporation Coweta-Fayette Electric Membership Corporation (EMC) provides electric and natural gas service to 58,000 customers in Georgia's Coweta, Fayette, Meriwether, Heard, Troop and Fulton counties. Currently, Coweta-Fayette EMC offers rebates on solar water heaters from $750 up to $1,500 as part of the Touchstone Energy Home Program. Solar

146

The Trials and Tribulations of Testing Water Heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The Trials and Tribulations of Testing Water Heaters The Trials and Tribulations of Testing Water Heaters Speaker(s): James Lutz Date: August 14, 2001 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Julie Osborn During our work on efficiency standards for electric water heaters, we discovered significant discrepancies between the rated and tested efficiencies of the highest rated electric resistance water heaters. For high efficiency electric resistance water heaters with an Energy Factor above .92, the heat losses are so small that minor flaws in the tank or obscure problems in the test procedure become more apparent. This seminar reports on our investigation into the causes of inconsistent results obtained during testing of high efficiency electric resistance water heaters at different test labs. We discovered some reasons for the

147

Linn County Rural Electric Cooperative - Solar Water Heater Rebate Program  

Broader source: Energy.gov (indexed) [DOE]

Linn County Rural Electric Cooperative - Solar Water Heater Rebate Linn County Rural Electric Cooperative - Solar Water Heater Rebate Program Linn County Rural Electric Cooperative - Solar Water Heater Rebate Program < Back Eligibility Agricultural Commercial Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Iowa Program Type Utility Rebate Program Rebate Amount $500 Provider Linn County Rural Electric Cooperative Association Linn County Rural Electric Cooperative Association (Linn County RECA) is a member-owned cooperative. To encourage energy efficiency, Linn County offers a number of rebates to commercial, residential, and agricultural customers. Owners of both new construction and existing buildings are eligible for a $500 rebate for solar water heaters. The water heaters must have an auxiliary tank of at least 40 gallons and the solar water heater

148

Rock Hill Utilities - Water Heater and Heat Pump Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

Rock Hill Utilities - Water Heater and Heat Pump Rebate Program Rock Hill Utilities - Water Heater and Heat Pump Rebate Program Rock Hill Utilities - Water Heater and Heat Pump Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heat Pumps Appliances & Electronics Water Heating Program Info State South Carolina Program Type Utility Rebate Program Rebate Amount Water Heater: up to $275 Heat Pump Replacement: $400 Provider Rock Hill Utilities Through the SmartChoice program, Rock Hill Utilities offers rebates for water heater and heat pump replacements. Information on financing for heat pumps can also be found on the web site listed above. If both the water heater and heat pump are purchased then the customer may qualify for the Great Rate program. The Great Rate program will add a 25% discount to a

149

Multi-step heater deployment in a subsurface formation  

DOE Patents [OSTI]

A method for installing a horizontal or inclined subsurface heater includes placing a heating section of a heater in a horizontal or inclined section of a wellbore with an installation tool. The tool is uncoupled from the heating section. A lead in section is mechanically and electrically coupled to the heating section of the heater. The lead-in section is located in an angled or vertical section of the wellbore.

Mason, Stanley Leroy (Allen, TX)

2012-04-03T23:59:59.000Z

150

Insulated conductor temperature limited heater for subsurface heating coupled in a three-phase WYE configuration  

DOE Patents [OSTI]

A heating system for a subsurface formation is described. The heating system includes a first heater, a second heater, and a third heater placed in an opening in the subsurface formation. Each heater includes: an electrical conductor; an insulation layer at least partially surrounding the electrical conductor; and an electrically conductive sheath at least partially surrounding the insulation layer. The electrical conductor is electrically coupled to the sheath at a lower end portion of the heater. The lower end portion is the portion of the heater distal from a surface of the opening. The first heater, the second heater, and the third heater are electrically coupled at the lower end portions of the heaters. The first heater, the second heater, and the third heater are configured to be electrically coupled in a three-phase wye configuration.

Vinegar, Harold J. (Bellaire, TX); Sandberg, Chester Ledlie (Palo Alto, CA)

2010-11-09T23:59:59.000Z

151

Advanced refinery process heater. Final report, (October 1983-September 1988)  

SciTech Connect (OSTI)

A prototype refinery process heater was designed, built and successfully tested, demonstrating the improvements available to heater design through the use of Zone-Controlled Pyrocore radiant gas burners. The 10 MMBtu/hr rated heater released 17 ppm NOx (corrected to 3% oxygen) under full load operation, the lowest NOx emissions technically and commercially achieved in this type of equipment without the use of post-combustion flue-gas processing. Operating with 400F combustion air preheat and a 500F process fluid outlet temperature, the heater achieved overall thermal efficiencies of 92.8% on a LHV basis due in part to the significantly improved performance of the radiant heat exchange section. The radiant burners used in the heater have been proven in performance and reliability, and have also been shown to be applicable to both new heater designs and retrofits into existing heaters. The improved radiant performance of the heater and the use of 'flameless' radiant burners eliminates tube burn-out failures in both the radiant and convective tube coils, further improving the reliability of equipment based on this design. Three separate U.S. Patents have been issued covering the heater design and the use of Zone-Controlled Pyrocore burners in this application.

Minden, A.C.; Buckley, G.G.

1989-04-01T23:59:59.000Z

152

NREL Develops Heat Pump Water Heater Simulation Model (Fact Sheet)  

SciTech Connect (OSTI)

A new simulation model helps researchers evaluate real-world impacts of heat pump water heaters in U.S. homes.

Hudon, K.

2012-05-01T23:59:59.000Z

153

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network [OSTI]

as conventional electric resistance water heaters, with thetwo technologies: (1) an electric resistance storage watertransfers heat from the electric resistance element to the

Franco, Victor

2011-01-01T23:59:59.000Z

154

Slurry fired heater cold-flow modelling  

SciTech Connect (OSTI)

This report summarizes the experimental and theoretical work leading to the scale-up of the SRC-I Demonstration Plant slurry fired heater. The scale-up involved a theoretical model using empirical relations in the derivation, and employed variables such as flow conditions, liquid viscosity, and slug frequency. Such variables have been shown to affect the heat transfer characteristics ofthe system. The model assumes that, if all other variables remain constant, the heat transfer coefficient can be scaled up proportional to D/sup -2/3/ (D = inside diameter of the fired heater tube). All flow conditions, liquid viscosities, and pipe inclinations relevant to the demonstration plant have indicated a slug flow regime in the slurry fired heater. The annular and stratified flow regimes should be avoided to minimize the potential for excessive pipe erosion and to decrease temperature gradients along the pipe cross section leading to coking and thermal stresses, respectively. Cold-flow studies in 3- and 6.75-in.-inside-diameter (ID) pipes were conducted to determine the effect of scale-up on flow regime, slug frequency, and slug dimensions. The developed model assumes that conduction heat transfer occurs through the liquid film surrounding the gas slug and laminar convective heat transfer to the liquid slug. A weighted average of these two heat transfer mechanisms gives a value for the average pipe heat transfer coefficient. The cold-flow work showed a decrease in the observed slug frequency between the 3- and 6.75-ID pipes. Data on the ratio of gas to liquid slug length in the 6.75-in. pipe are not yet complete, but are expected to yield generally lower values than those obtained in the 3-in. pipe; this will probably affect the scale-up to demonstration plant conditions. 5 references, 15 figures, 7 tables.

Moujaes, S.F.

1983-07-01T23:59:59.000Z

155

Wood pellet production  

SciTech Connect (OSTI)

Southern Energy Limited's wood pellet refinery, Bristol, Florida, produces wood pellets for fuel from scrap wood from a nearby sawmill and other hog fuel delivered to the plant from nearby forest lands. The refinery will provide 50,000 tons of pellets per year to the Florida State Hospital at Chattahoochee to fire recently converted boilers in the central power plant. The pellets are densified wood, having a moisture content of about 10% and a heating value of 8000 Btu/lb. They are 0.5 inches in diameter and 2 to 3 inches in length.

Moore, J.W.

1983-08-01T23:59:59.000Z

156

Using the sun and waste wood to heat a central Ohio home. Final technical report  

SciTech Connect (OSTI)

The description of a house in Ohio built on a south facing slope with two levels above ground on the north, east, and west sides and three levels exposed to the southern winter Sun is presented. The floor plan, a general history of the project, the operation of the system, the backup heat source (wood), the collection of data, and the procedure for determining actual heat loss are described. Additionally, the calculation of the solar contribution percentage and the amount of mass to be included in the greenhouse and problems with an indirect gain wall are discussed. The location of the wood stove in the system is noted. The east wall temperature data are given. Soil temperature, air infiltration, thermal comfort, and energy usage are discussed. (MCW).

Not Available

1981-01-01T23:59:59.000Z

157

Woods for Learning Strategy Woods for Learning Strategy | 32 | Woods for Learning Strategy  

E-Print Network [OSTI]

Strategy Woods for Learning #12;Woods for Learning Strategy Woods for Learning Strategy | 32 | Woods for Learning Strategy Foreword We want our young people to be successful learners, confident the use of woods for learning. Woodlands provide a rich resource for a range of learning opportunities

158

Indoor air pollution in rural China: Cooking fuels, stoves, and health status  

SciTech Connect (OSTI)

Solid fuels are a major source of indoor air pollution, but in less developed countries the short-term health effects of indoor air pollution are poorly understood. The authors conducted a large cross-sectional study of rural Chinese households to determine associations between individual health status and domestic cooking as a source of indoor air pollution. The study included measures of health status as well as measures of indoor air-pollution sources, such as solid cooking fuels and cooking stoves. Compared with other fuel types, coal was associated with a lower health status, including negative impacts on exhaled carbon monoxide level, forced vital capacity, lifetime prevalence of chronic obstructive pulmonary disease and asthma, and health care utilization. Decreasing household coal use, increasing use of improved stove technology, and increasing kitchen ventilation may decrease the short-term health effects of indoor air pollution.

Peabody, J.W.; Riddell, T.J.; Smith, K.R.; Liu, Y.P.; Zhao, Y.Y.; Gong, J.H.; Milet, M.; Sinton, J.E. [Amgen Inc., Thousand Oaks, CA (United States)

2005-03-15T23:59:59.000Z

159

Georgia Power- Residential Solar and Heat Pump Water Heater Rebate (Georgia)  

Broader source: Energy.gov [DOE]

Georgia Power customers may be eligible for rebates up to $250 each toward the installation costs of a 50 gallon or greater solar water heater or heat pump water heater. The solar water heater or...

160

ELECTRICAL HEATERS FOR THERMO-MECHANICAL TESTS AT THE STRIPA MINE  

E-Print Network [OSTI]

5.5 Dewatering Pump 6. ELECTRICAL HEATER CONTROL SYSTEMS 6.1water influx ABSTRACT Electrical heaters were installed atcanister) which houses the electrical heater elements; c. d.

Burleigh, R.H.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Solar pool heaters: The simplest use of active solar energy  

SciTech Connect (OSTI)

Solar pool heating is the most attractive solar water heating market today, because most pool heaters pay back their purchase price in lower utility bills in two to three years. This article describes why solar pool heaters are popular and their design, operation, and return on investment. 1 fig.

Sheinkopf, K. [Florida Solar Energy Center, Cocoa, FL (United States)

1997-11-01T23:59:59.000Z

162

Friction of wood on steel.  

E-Print Network [OSTI]

?? This thesis deals with the experimental description of friction between steel and wood materials, specifically laminated veneer lumber (LVL) and pine wood with two (more)

Koubek, Radek

2014-01-01T23:59:59.000Z

163

Chopwell Wood Health Project  

E-Print Network [OSTI]

Chopwell Wood Health Project An innovative project of school visits and General Practitioner. The project took place at Chopwell Wood a 360 hectare mixed woodland managed by the Forestry Commission to carry on being involved in the project. Next stage of the project Although the project leader has now

164

Tri-County Electric Cooperative - Energy Efficient Water Heater Rebate  

Broader source: Energy.gov (indexed) [DOE]

Tri-County Electric Cooperative - Energy Efficient Water Heater Tri-County Electric Cooperative - Energy Efficient Water Heater Rebate Program Tri-County Electric Cooperative - Energy Efficient Water Heater Rebate Program < Back Eligibility Commercial Residential Savings Category Appliances & Electronics Water Heating Program Info State Texas Program Type Utility Rebate Program Rebate Amount $75 Provider Tri-County Electric Cooperative Tri-County Electric Cooperative offers a $75 rebate on the purchase of energy-efficient electric water heaters. The rebate is valid for new or replacement units which have an Energy Factor Rating of 0.90 or higher. The minimum tank size is 40 gallons, with a minimum 4,500 watt heating element. For validation purposes, a copy of the sales or installation receipt must accompany the [http://www.tcectexas.com/Forms/water%20heater%20rebate%20form.pdf

165

Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate  

Broader source: Energy.gov (indexed) [DOE]

Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate Program Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Maximum Rebate $600 Program Info State Florida Program Type Utility Rebate Program Rebate Amount 0.01 per BTU output Provider Clay Electric Co-op Clay Electric Cooperative (CEC) provides a rebate of $0.01 per BTU output to its residential members when they purchase qualified solar water heaters. This rebate is capped at 60,000 BTUs per system, or $600. Eligible solar water heaters can be either passive or active systems. The proposed solar system must meet Florida Solar Energy Center (FSEC) specifications and be installed by a contractor certified to install solar water heating

166

Heat Pump Swimming Pool Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Swimming Pool Heaters Swimming Pool Heaters Heat Pump Swimming Pool Heaters May 29, 2012 - 1:49pm Addthis How a heat pump works. How a heat pump works. How They Work Heat pumps use electricity to capture heat and move it from one place to another. They don't generate heat. As the pool pump circulates the swimming pool's water, the water drawn from the pool passes through a filter and the heat pump heater. The heat pump heater has a fan that draws in the outside air and directs it over the evaporator coil. Liquid refrigerant within the evaporator coil absorbs the heat from the outside air and becomes a gas. The warm gas in the coil then passes through the compressor. The compressor increases the heat, creating a very hot gas that then passes through the condenser. The condenser transfers the heat from the hot gas to the cooler pool water circulating

167

Cost of Increased Energy Efficiency for Residential Water Heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Cost of Increased Energy Efficiency for Residential Water Heaters Cost of Increased Energy Efficiency for Residential Water Heaters Speaker(s): Alex Lekov Date: March 22, 2001 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Julie Osborn This presentation describes the analysis of the costs of increased energy efficiency for residential water heaters. Here, we focus on the cost and efficiency data for electric and gas-fired water heaters. This data formed the basis of the Technical Support Document for the Department of Energy's (DOE) Final Rule on Water Heaters. The engineering analysis uses computer simulation models to investigate the efficiency improvements due to design options and combinations thereof. The analysis covers four polyurethane foam insulation types based on non-ozone-depleting substances as blowing

168

Tankless Demand Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Demand Water Heater Basics Demand Water Heater Basics Tankless Demand Water Heater Basics August 19, 2013 - 2:57pm Addthis Illustration of an electric demand water heater. At the top of the image, the heating unit is shown. Cold water flows in one end of a pipe, flows through and around several curved pipes over the heating elements, and out the other end as hot water. Beneath the heating unit, a typical sink setup is shown. The sink has two pipes coming out the bottom, one for the hot water line and one for the cold water line. Both pipes lead to the heating unit, which is installed in close proximity to the area of hot water use, and is connected to a power source (110 or 220 volts). Demand (tankless or instantaneous) water heaters have heating devices that are activated by the flow of water, so they provide hot water only as

169

Tankless Demand Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tankless Demand Water Heater Basics Tankless Demand Water Heater Basics Tankless Demand Water Heater Basics August 19, 2013 - 2:57pm Addthis Illustration of an electric demand water heater. At the top of the image, the heating unit is shown. Cold water flows in one end of a pipe, flows through and around several curved pipes over the heating elements, and out the other end as hot water. Beneath the heating unit, a typical sink setup is shown. The sink has two pipes coming out the bottom, one for the hot water line and one for the cold water line. Both pipes lead to the heating unit, which is installed in close proximity to the area of hot water use, and is connected to a power source (110 or 220 volts). Demand (tankless or instantaneous) water heaters have heating devices that are activated by the flow of water, so they provide hot water only as

170

Clark Public Utilities - Solar Water Heater Rebate | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Clark Public Utilities - Solar Water Heater Rebate Clark Public Utilities - Solar Water Heater Rebate Clark Public Utilities - Solar Water Heater Rebate < Back Eligibility Commercial Residential Savings Category Heating & Cooling Solar Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount $500 Provider Clark PUD Clark Public Utilities offers a rebate of $500 to customers who install a solar water heating system. Customers must own the residence or business where the solar water heating system is installed and must have an electric water heater. In addition, Clark Public Utilities offers a [http://dsireusa.org/incentives/incentive.cfm?Incentive_Code=WA29F&re=1&ee=1 loan program] for eligible solar water heater equipment. For additional information, call Energy Services at (360) 992-3355.

171

Solar Water Heater Roadmap Leads Path to Market Expansion (Fact Sheet)  

SciTech Connect (OSTI)

Innovative strategy to reduce installed cost of solar water heater systems can rival conventional natural gas water heaters in the marketplace.

Not Available

2012-09-01T23:59:59.000Z

172

Evaluation of TANK water heater simulation model as embedded in HWSim  

E-Print Network [OSTI]

this scheme for operating TANK with HWSim is successful.LBNL # Evaluation of TANK water heater simulation model asCalifornia. Evaluation of TANK water heater simulation model

Lutz, Jim

2012-01-01T23:59:59.000Z

173

Review of International Methods of Test to Rate the Efficiency of Water Heaters  

E-Print Network [OSTI]

Conservation Standards for Residential Water Heaters, Direct Heating Equipment, and PoolConservation Program for Consumer Products: Test Procedures for Residential Water Heaters, Direct Heating Equipment, and Pool

Lutz, Jim

2012-01-01T23:59:59.000Z

174

Heat Pump Water Heater Performance in  

Broader source: Energy.gov (indexed) [DOE]

searc searc e er tra A Research Institute of the University of Central Florida FLORIDA SOLAR ENERGY CENTER - A Re h Institut of the Univ sity of Cen l Florida searc e er tra Heat Pump Water Heater Performance in Laboratory House Building America Technical Update 2013 ACI National Home Performance Conference April 29- 30 , 2013 Carlos J. Colon carlos@fsec.ucf.edu A Research Institute of the University of Central Florida FLORIDA SOLAR ENERGY CENTER - A Re h Institut of the Univ sity of Cen l Florida FLORIDA SOLAR ENERGY CENTER - A Research Institute of the University of Central Florida Hot Water Systems (HWS) Laboratory FSEC Grounds, Florida (east coast) 2009 -Present (Currently fourth testing rotation) FLORIDA SOLAR ENERGY CENTER - A Research Institute of the University of Central Florida

175

Marcelo A. Wood Marcelo A. Wood, Ph.D.  

E-Print Network [OSTI]

Marcelo A. Wood 1 Marcelo A. Wood, Ph.D. Curriculum Vitae June, 2013 Current Appointment: Associate, University of California, Irvine #12;Marcelo A. Wood 2 Teaching Experience: since joining UCI 2006, American College of Neuropsychopharmacology (ACNP) #12;Marcelo A. Wood 3 Journal/Editorial Review Service

Wood, Marcelo A.

176

Utilization of Heat Pump Water Heaters for Load Management  

SciTech Connect (OSTI)

The Energy Conservation Standards for Residential Water Heaters require residential electric storage water heaters with volumes larger than 55 gallons to have an energy factor greater than 2.0 after April 2015. While this standard will significantly increase the energy efficiency of water heaters, large electric storage water heaters that do not use heat pump technologies may no longer be available. Since utilities utilize conventional large-volume electric storage water heaters for thermal storage in demand response programs, there is a concern that the amended standard will significantly limit demand response capacity. To this end, Oak Ridge National Laboratory partnered with the Tennessee Valley Authority to investigate the load management capability of heat pump water heaters that meet or exceed the forthcoming water heater standard. Energy consumption reduction during peak periods was successfully demonstrated, while still meeting other performance criteria. However, to minimize energy consumption, it is important to design load management strategies that consider the home s hourly hot water demand so that the homeowner has sufficient hot water.

Boudreaux, Philip R [ORNL; Jackson, Roderick K [ORNL; Munk, Jeffrey D [ORNL; Gehl, Anthony C [ORNL; Lyne, Christopher T [ORNL

2014-01-01T23:59:59.000Z

177

WOOD RESEARCH 53 (4): 2008  

E-Print Network [OSTI]

1 WOOD RESEARCH 53 (4): 2008 1-12 CAMBIAL ACTIVITY AND WOOD FORMATION IN BEECH FAGUS SYLVATICA, Department of Wood Science and Technology, Ljubljana, Slovenia Jozica Griar Slovenian Forestry Institute (Fagus sylvatica), cambium, wood formation, cell differentiation, xylem growth rings, Gompertz function

Cufar, Katarina

178

WOOD RESEARCH 52 (2): 2007  

E-Print Network [OSTI]

1 WOOD RESEARCH 52 (2): 2007 1-10 WOOD FORMATION IN NORWAY SPRUCE PICEA ABIES STUDIED BY PINNING Zupani, Katarina Cufar, Primoz Oven University of Ljubljana, Biotechnical Faculty, Department of Wood methods for examining wood formation. Pinning induced desiccation of differentiated xylem, necrosis

Cufar, Katarina

179

Generating power with waste wood  

SciTech Connect (OSTI)

Among the biomass renewables, waste wood has great potential with environmental and economic benefits highlighting its resume. The topics of this article include alternate waste wood fuel streams; combustion benefits; waste wood comparisons; waste wood ash; pilot scale tests; full-scale test data; permitting difficulties; and future needs.

Atkins, R.S.

1995-02-01T23:59:59.000Z

180

The Impact of Blowing Agents on Residential Water Heater Performance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The Impact of Blowing Agents on Residential Water Heater Performance The Impact of Blowing Agents on Residential Water Heater Performance Title The Impact of Blowing Agents on Residential Water Heater Performance Publication Type Report LBNL Report Number LBNL-47352 Year of Publication 2001 Authors Lekov, Alexander B., James D. Lutz, Camilla Dunham Whitehead, and James E. McMahon Document Number LBNL-47352 Date Published January 12 Abstract The National Appliance Energy Conservation Act of 1987 (NAECA) requires the U.S. Department of Energy (DOE) to consider amendments to the energy conservation standards to increase energy efficiency in residential water heaters. A driving force affecting efficiency is the ozone-depletion regulation regarding blowing agents for insulation in all water heater fuel types. This paper presents results of cost and efficiency impacts of three potential blowing agents. Residential water heaters are typically insulated with polyurethane foam in the space between the tank and the jacket. Currently, water heater manufacturers use HCFC-141b, an ozone-depleting substance, as a blowing agent. After 2003, as a result of the Montreal Protocol (1993), manufacturers must use blowing agents that do not deplete the ozone layer. The analysis presented in this paper considers three replacement candidates, HFC-245fa, HFC-134a, and cyclopentane by comparing their efficiency and cost effectiveness when applied to water heater insulation. This analysis used computer simulation models and other analytical methods to investigate the efficiency improvements due to different design options, when alternative blowing agents are applied. The calculations were based on the DOE test procedure for residential water heaters. The analysis used average manufacturer, retailer, and installer costs to calculate the total consumer costs. Consumer operating expenses were calculated based on modeled energy consumption under test procedure conditions and U.S. average energy prices. With this information, a cost-efficiency relationship was developed to show the average manufacturer and consumer cost to achieve increased efficiency.

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Blue Ridge Mountain Electric Membership Corporation - Water Heater Rebate  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Blue Ridge Mountain Electric Membership Corporation - Water Heater Rebate Program Blue Ridge Mountain Electric Membership Corporation - Water Heater Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Commercial Heating & Cooling Cooling Construction Design & Remodeling Ventilation Manufacturing Heat Pumps Appliances & Electronics Water Heating Program Info State Georgia Program Type Utility Rebate Program Rebate Amount In-Home Energy Evaluation Program Windows: $500 Duct Repair: $500 Rehabilitation Work: $250 HVAC Replacement: $250/unit HVAC Tune-up: $150/unit Insulation: $500 Water Heater and Pipe Insulation: $50 Air Sealing: $500 Energy Right Program

182

Wood Heating Fuel Exemption  

Broader source: Energy.gov [DOE]

This statute exempts from the state sales tax all wood or "refuse-derived" fuel used for heating purposes. The law does not make any distinctions about whether the qualified fuels are used for...

183

Woods for Health Strategy Woods for Health Strategy | 32 | Woods for Health Strategy  

E-Print Network [OSTI]

Strategy Woods for Health #12;Woods for Health Strategy Woods for Health Strategy | 32 | Woods for Health Strategy Foreword Like the rest of the western world, Scotland experiences growing rates a key role in helping to promote better physical and mental health for all by providing greenspace

184

Gregory H. Woods  

Broader source: Energy.gov (indexed) [DOE]

H. Woods H. Woods Department· of Energy Fermi Site Office Post Office Box 2000 Batavia, Illinois 60510 JAN 1 1 2DD Office of the General Counsel GC-1, FORS SUBJECT: FERMI SITE OFFICE (FSO) 2013 ANNUAL NATIONAL ENVIRONMENTAL POLICY ACT (NEPA) PLANNING SUMMARY Section 5(a) (7) of Department Of Energy Order 451.1 B Change 2, NEPA Compliance Program, requires each Secretarial Officer and Head of Field Organization to submit an annual NEPA

185

THE EFFECT OF LOCATION OF THE PREDICTED PERFORMANCE OF A HEAT PUMP WATER HEATER  

E-Print Network [OSTI]

#12;THE EFFECT OF LOCATION OF THE PREDICTED PERFORMANCE OF A HEAT PUMP WATER HEATER Laboratory testing and field testing have shown that a heat pump water heater (HPWH) uses about half the electrical energy input that an electric resistance water heater does. However, since the heat pump water heater

Oak Ridge National Laboratory

186

Space Heaters The University recognizes that individuals have different levels of comfort associated with  

E-Print Network [OSTI]

used must be currently UL (Underwriters Laboratory) approved. 4. Approved space heaters must be fan driven. Space heaters with heated coils are not permitted. 5. Space heaters must have a thermostat that shuts unit off when a certain temperature is reached. 6. Space heaters must have a tip-over shutdown

de Lijser, Peter

187

Electrical noise characteristics of a doped silicon microcantilever heater-thermometer  

E-Print Network [OSTI]

Electrical noise characteristics of a doped silicon microcantilever heater-thermometer Elise A with resistive heater-thermometers,10­13 there is a lack of published reports on the electrical noise silicon heater- thermometer cantilevers.12 However, a key difference is that doped silicon heater-thermometers

King, William P.

188

Solar Water Heaters and the Economy | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Water Heaters and the Economy Water Heaters and the Economy Solar Water Heaters and the Economy July 11, 2012 - 11:59am Addthis Ernie Tucker Editor, National Renewable Energy Laboratory These are the days of hot sun and mortgage refinance frenzy. Somehow, they've both combined in my mind to make me ponder the economics of a solar water heater. Because the sun's been beating down on our garden hose, the initial flush of water can be very hot. The warm spray reminded me of the times on camping trips when we'd bring along a portable solar shower -- essentially a black plastic bag with a tube and shower nozzle -- for bathing. While not an endless supply (perhaps 10 gallons), it was a very enjoyable luxury. Of course, it assumes that there's plenty of sunshine, but if so -- voila -- a warm and sudsy campsite clean-up is possible.

189

Grays Harbor PUD - Solar Water Heater Rebate | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Grays Harbor PUD - Solar Water Heater Rebate Grays Harbor PUD - Solar Water Heater Rebate Grays Harbor PUD - Solar Water Heater Rebate < Back Eligibility Commercial Industrial Residential Savings Category Heating & Cooling Solar Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount $600 Provider Grays Harbor PUD Since October 2001, Grays Harbor PUD has offered a rebate program for the installation of solar water heaters. Rebates of $600 are available for the installation of solar collectors of 40 square feet or more. Only customers who currently use electricity for hot water are eligible. This rebate is available on a case-by-case basis, so you must contact the utility in order to take advantage of it. Customers may choose a [http://dsireusa.org/incentives/incentive.cfm?Incentive_Code=WA09F&re=1&ee=1

190

List of Water Heaters Incentives | Open Energy Information  

Open Energy Info (EERE)

Heaters Incentives Heaters Incentives Jump to: navigation, search The following contains the list of 973 Water Heaters Incentives. CSV (rows 1-500) CSV (rows 501-973) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio - Commercial New Construction Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Industrial Local Government Municipal Utility Nonprofit Schools State Government Central Air conditioners Chillers Comprehensive Measures/Whole Building Custom/Others pending approval Energy Mgmt. Systems/Building Controls Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Motors Water Heaters Commercial Cooking Equipment Commercial Refrigeration Equipment Room Air Conditioners Yes AEP Public Service Company of Oklahoma - Residential Efficiency Rebate Program (Oklahoma) Utility Rebate Program Oklahoma Residential Building Insulation

191

Covered Product Category: Gas Storage Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Gas Storage Water Heaters Gas Storage Water Heaters Covered Product Category: Gas Storage Water Heaters October 7, 2013 - 10:43am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including gas storage water heaters, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

192

Solar Water Heaters and the Economy | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heaters and the Economy Solar Water Heaters and the Economy Solar Water Heaters and the Economy July 11, 2012 - 11:59am Addthis Ernie Tucker Editor, National Renewable Energy Laboratory These are the days of hot sun and mortgage refinance frenzy. Somehow, they've both combined in my mind to make me ponder the economics of a solar water heater. Because the sun's been beating down on our garden hose, the initial flush of water can be very hot. The warm spray reminded me of the times on camping trips when we'd bring along a portable solar shower -- essentially a black plastic bag with a tube and shower nozzle -- for bathing. While not an endless supply (perhaps 10 gallons), it was a very enjoyable luxury. Of course, it assumes that there's plenty of sunshine, but if so -- voila -- a

193

Grays Harbor PUD - Solar Water Heater Loan | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heater Loan Solar Water Heater Loan Grays Harbor PUD - Solar Water Heater Loan < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Maximum Rebate not specified Program Info State District of Columbia Program Type Utility Loan Program Rebate Amount not specified Provider Grays Harbor PUD Since October 2001, Grays Harbor PUD has offered a low-interest loan program (currently 4.0%) for the installation of solar water heaters. Loans are available for the installation of solar collectors of 40 square feet or more. The loans are provided through local lenders, with interest subsidized by the PUD. Only customers who currently use electricity for hot water are eligible. Pre-approval is required for this loan and loan amounts are determined on a case-by-case basis.

194

New Braunfels Utilities - Residential Solar Water Heater Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

New Braunfels Utilities - Residential Solar Water Heater Rebate New Braunfels Utilities - Residential Solar Water Heater Rebate Program New Braunfels Utilities - Residential Solar Water Heater Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Texas Program Type Utility Rebate Program Rebate Amount $0.265/kWh Provider New Braunfels Utilities New Braunfels Utilities offers a rebate for residential customers who purchase and install solar water heating systems on eligible homes. A rebate of the equivalent of $0.265 per kWh is available to these customers. The maximum rebate amount is $900 for participating customers. Applicants must have an active residential electric service account with NBU in order to be eligible. Solar water heaters must preheat water for an electric

195

FS: heat pump water heaters | The Better Buildings Alliance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Food Service » Install a heat pump Food Service » Install a heat pump water heaterand reduce water heating energy up to 70% using the commercial heat pump water heater specificat Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Install a heat pump water heaterand reduce water heating energy up to 70% using the commercial heat pump water heater specification The Food Service team developed a Commercial Heat Pump Water Heater Specification that can be used to reduce water heating energy by 70%. An older, electric resistance water heater (operated in a building with a hot water demand of 500 gallons a day) can cost more than $3,500 each year

196

Heat Recovery Consideration for Process Heaters and Boilers  

E-Print Network [OSTI]

The largest single area for industrial energy conservation is in the improvement of combustion efficiencies for heaters and boilers. A number of methods can be employed to recover heat. The most common are by use of recuperative air preheaters...

Kumar, A.

1984-01-01T23:59:59.000Z

197

Split system CO2 heat pump water heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Split-system-CO2-heat-pump-water-heaters- Sign In About | Careers | Contact | Investors | bpa.gov Search Policy & Reporting Expand Policy & Reporting EE Sectors Expand EE...

198

An Analysis of Steam Process Heater Condensate Drainage Options  

E-Print Network [OSTI]

The production and reliability performance of Steam Process Heaters can be significantly affected by the condensate drainage design that is employed. There are currently a variety of drainage options which can be confusing to a system designer who...

Risko, J. R.

199

Monitoring SERC Technologies: On-Demand Tankless Water Heaters  

Broader source: Energy.gov [DOE]

A webinar by Ethan MacCormick, VP for Services to Energy Businesses at Performance Systems Development, about On-Demand Tankless Water Heaters and how to properly monitor the installation.

200

New Home Buyer Solar Water Heater Trade-Off Study  

SciTech Connect (OSTI)

This report details the results of a research conducted in 1998 and 1999 and outlines a marketing deployment plan designed for businesses interested in marketing solar water heaters in the new home industry.

Symmetrics Marketing Corporation

1999-08-18T23:59:59.000Z

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Ninety - Two Percent Minimum Heater Efficiency By 1980  

E-Print Network [OSTI]

Technology is now available to increase heater efficiencies to 92 percent and more. By 1980, this technology will be field proven and corrosion and reliability problems identified and resolved. Recent studies have shown that a minimum efficiency...

Mieth, H. C.; Hardie, J. E.

1980-01-01T23:59:59.000Z

202

Marshall Municipal Utilities- Solar Thermal Water Heater Rebate Program  

Broader source: Energy.gov [DOE]

Marshall Municipal Utilities (MMU) offers residential customers rebates for installing a ENERGY STAR Solar Thermal Water Heater. Rebates are based on the size of the system; MMU offers $20 per...

203

Temperature limited heater utilizing non-ferromagnetic conductor  

DOE Patents [OSTI]

A heater is described. The heater includes a ferromagnetic conductor and an electrical conductor electrically coupled to the ferromagnetic conductor. The ferromagnetic conductor is positioned relative to the electrical conductor such that an electromagnetic field produced by time-varying current flow in the ferromagnetic conductor confines a majority of the flow of the electrical current to the electrical conductor at temperatures below or near a selected temperature.

Vinegar; Harold J. (Bellaire, TX), Harris; Christopher Kelvin (Houston, TX)

2012-07-17T23:59:59.000Z

204

Estimating the Cost and Energy Efficiency of a Solar Water Heater |  

Broader source: Energy.gov (indexed) [DOE]

Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater May 30, 2012 - 3:09pm Addthis Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR What does this mean for me? Solar water heaters cost more to purchase and install but may save you money in the long run. Estimate the annual operating costs and compare several solar water heaters to determine whether it is worth investing in a more efficient system. Solar water heating systems usually cost more to purchase and install than conventional water heating systems. However, a solar water heater can

205

Estimating the Cost and Energy Efficiency of a Solar Water Heater |  

Broader source: Energy.gov (indexed) [DOE]

Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater May 30, 2012 - 3:09pm Addthis Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR What does this mean for me? Solar water heaters cost more to purchase and install but may save you money in the long run. Estimate the annual operating costs and compare several solar water heaters to determine whether it is worth investing in a more efficient system. Solar water heating systems usually cost more to purchase and install than conventional water heating systems. However, a solar water heater can

206

Wye Wood: the wider wood : A project description and evaluation page 1 January 2007  

E-Print Network [OSTI]

Wye Wood: the wider wood : A project description and evaluation page 1 January 2007 Wye Wood: the wider wood A project description and evaluation Report written by: Dr Frances Howie Associate Director Parrott Health Development Worker, Wye Wood: the wider wood #12;Wye Wood: the wider wood : A project

207

Determining Benefits and Costs of Improved Water Heater Efficiencies  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Determining Benefits and Costs of Improved Water Heater Efficiencies Determining Benefits and Costs of Improved Water Heater Efficiencies Title Determining Benefits and Costs of Improved Water Heater Efficiencies Publication Type Report LBNL Report Number LBNL-45618 Year of Publication 2000 Authors Lekov, Alexander B., James D. Lutz, Xiaomin Liu, Camilla Dunham Whitehead, and James E. McMahon Document Number LBNL-45618 Date Published May 4 Abstract Economic impacts on individual consumers from possible revisions to U.S. residential water heater energy-efficiency standards are examined using a life-cycle cost (LCC) analysis. LCC is the consumer's cost of purchasing and installing a water heater and operating it over its lifetime. This approach makes it possible to evaluate the economic impacts on individual consumers from the revised standards. The methodology allows an examination of groups of the population which benefit or lose from suggested efficiency standards. The results show that the economic benefits to consumers are significant. At the efficiency level examined in this paper, 35% of households with electric water heaters experience LCC savings, with an average savings of $106, while 4% show LCC losses, with an average loss of $40 compared to a pre-standard LCC average of $2,565. The remainder of the population (61%) are largely unaffected.

208

O R E G O N S T A T E U N I V E R S I T Y E x t e n s i o n S e r v i c e FOOD STORAGE FOR EMERGENCIES  

E-Print Network [OSTI]

outages. Do you have a wood stove, gas or charcoal barbecue, propane camp stoves, or cookers? You can

Tullos, Desiree

209

CCA-Treated Wood  

Science Journals Connector (OSTI)

Abstract Chromated copper arsenate (CCA) is a chemical preservative that protects wood from rotting due to insects and microbial agents. It has been used to pressure-treated lumber since the 1930s. Since the 1970s, the majority of the wood used in residential settings was CCA-treated wood. It is a registered chemical pesticide that is subject to US Environmental Protection Agency's (EPA's) regulation. The pesticide registration for CCA was modified as a result of a voluntary agreement reached in February 2002 between the registrants and EPA, in order to transition to a new generation of preservatives for most nonindustrial applications. That agreement permitted the use of CCA for all existing registered uses until December 2003 and the continued sale and distribution of CCA-treated wood treated in accordance with the label. After 1 January 2004, following label amendment, CCA was permitted and continues to be sold to treat wood for many uses. This article is a revision of the previous edition article by C. Charles Barton and Thomas T. Newton, volume 1, pp 489490, 2005, Elsevier Inc.

C. Barton

2014-01-01T23:59:59.000Z

210

Precision wood particle feedstocks  

DOE Patents [OSTI]

Wood particles having fibers aligned in a grain, wherein: the wood particles are characterized by a length dimension (L) aligned substantially parallel to the grain, a width dimension (W) normal to L and aligned cross grain, and a height dimension (H) normal to W and L; the L.times.H dimensions define two side surfaces characterized by substantially intact longitudinally arrayed fibers; the W.times.H dimensions define two cross-grain end surfaces characterized individually as aligned either normal to the grain or oblique to the grain; the L.times.W dimensions define two substantially parallel top and bottom surfaces; and, a majority of the W.times.H surfaces in the mixture of wood particles have end checking.

Dooley, James H; Lanning, David N

2013-07-30T23:59:59.000Z

211

Woods In and Around Towns: Phase II  

E-Print Network [OSTI]

Policy WIAT Woods In and Around Towns: Phase II #12;2 | Woods In and Around Towns: Phase II working with Forestry Commission Scotland on Woods In and Around Towns #12;Woods In and Around Towns: Phase II Woods In and Around Towns: Phase II | 3 What is this about? The Woods In and Around Towns (WIAT) Programme provides

212

April, 2006 Allen W. Wood  

E-Print Network [OSTI]

1 April, 2006 Vita Allen W. Wood Academic Address: Philosophy Department, Bldg 90 Stanford University Stanford, CA 94305-2155 Telephone 650-723-2587 Fax 650-723-0985 E-mail: Allen.Wood University, 1999-2000. Professor of Philosophy, Stanford University, 1999-2001 Ward W. and Priscilla B. Woods

Zalta, Edward N.

213

Inaugural 2012 Kristie Ann Wood  

E-Print Network [OSTI]

Inaugural 2012 Kristie Ann Wood Scholarship Award Call for Nominations We are delighted to announce the Inaugural 2012 Kristie Ann Wood Scholarship Award for an Outstanding Women's, Gender, and Sexualities (WGSS Wood, a feminist mother, wife, friend, daughter, and lawyer who is remembered by her loved ones

Alpay, S. Pamir

214

Environmental Impacts of Treated Wood  

E-Print Network [OSTI]

Environmental Impacts of Treated Wood 6495_C000.fm Page iii Wednesday, February 1, 2006 5:48 PM #12 associated with treated wood. Bill Hinkley died on September 12, 2005, shortly before the completion received contributions from many of the world's leading scientists on the subject of treated wood, and we

Florida, University of

215

The Asian Wood Pellet Markets  

E-Print Network [OSTI]

The Asian Wood Pellet Markets Joseph A. Roos and Allen M. Brackley United States Department.S. Department of Agriculture, Forest Service, Pacific Northwest Research Station, Alaska Wood Utilization Wood Pellet plant in North Pole, Alaska. Clockwise from upper left: pelleting machine; pellets bagged

216

Heat Pump Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Water Heater Basics Water Heater Basics Heat Pump Water Heater Basics August 19, 2013 - 2:59pm Addthis Illustration of a heat pump water heater, which looks like a tall cylinder with a small chamber on top and a larger one on the bottom. In the top chamber are a fan, a cylindrical compressor, and an evaporator that runs along the inside of the chamber. Jutting out from the exterior of the bottom chamber is a temperature and pressure relief valve. This valve has a tube called a hot water outlet attached to the top. Below the valve is the upper thermostat, a small square outside the cylinder that is attached to a curved tube inside the heater. Resistance elements run from the upper thermostat to the similarly shaped lower thermostat. Below the lower thermostat is a drain valve with a cold water inlet attached to the top. Inside the cylinder is an anode, a series of thin tubes running through the bottom chamber to a coiled tube called a condenser. Insulation runs along the inside of the cylinder.

217

Performance characteristics of solar air heater with surface mounted obstacles  

Science Journals Connector (OSTI)

Abstract The performance of conventional solar air heaters (SAHs) can be improved by providing obstacles on the heated wall (i.e. on the absorber plate). Experiments have been performed to collect heat transfer and flow-friction data from an air heater duct with delta-shaped obstacles mounted on the absorber surface and having an aspect ratio 6:1 resembling the conditions close to the solar air heaters. This study encompassed for the range of Reynolds number (Re) from 2100 to 30,000, relative obstacle height (e/H) from 0.25 to 0.75, relative obstacle longitudinal pitch (Pl/e) from 3/2 to 11/2, relative obstacle transverse pitch (Pt/b) from 1 to 7/3 and the angle of incidence (?) varied from 30 to 90. The thermo-hydraulic performance characteristics of SAH have been compared with the previous published works and the optimum range of the geometries have been explored for the better performance of such air-heaters compared to the other designs of solar air heaters.

Adisu Bekele; Manish Mishra; Sushanta Dutta

2014-01-01T23:59:59.000Z

218

The Wood Duck  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Wood Duck Wood Duck Nature Bulletin No. 502-A October 13, 1973 Forest Preserve District of Cook County George W. Dunne, President Roland F. Eisenbeis, Supt. of Conservation THE WOOD DUCK Of all the fowl that swim, the Wood Duck is a most unusual bird. They perch in trees like jaybirds, and nest in tree holes like woodpeckers. The hens do not quack like the females of most ducks, and the drakes are dressed in a riot of gaudy colors. Each summer we see dozens of them -- more than any other kind of wild duck -- rear their families of ducklings on and around the streams, ponds, lakes and sloughs of Cook County's forest preserves. Words can scarcely describe the brilliance of the drake's plumage. The head, crest and back glint with iridescent greens, purples and blues. The eyes are red, the throat white, and the bill orange-red. The breast is wine-colored flecked with white, the belly is white, and the sides are buff. The woodie is about midway in size between the mallard and the blue-winged teal. The drakes weigh about a pound and a half. The hen is smaller and plainer, with a gray-brown head and body, a white throat, and a conspicuous white ring around the eye. Her voice is a shrill, squealing "whoo-eek", while the male's is a mere squeak.

219

Rheological Model for Wood  

E-Print Network [OSTI]

Wood as the most important natural and renewable building material plays an important role in the construction sector. Nevertheless, its hygroscopic character basically affects all related mechanical properties leading to degradation of material stiffness and strength over the service life. Accordingly, to attain reliable design of the timber structures, the influence of moisture evolution and the role of time- and moisture-dependent behaviors have to be taken into account. For this purpose, in the current study a 3D orthotropic elasto-plastic, visco-elastic, mechano-sorptive constitutive model for wood, with all material constants being defined as a function of moisture content, is presented. The corresponding numerical integration approach, with additive decomposition of the total strain is developed and implemented within the framework of the finite element method (FEM). Moreover to preserve a quadratic rate of asymptotic convergence the consistent tangent operator for the whole model is derived. Functionality and capability of the presented material model are evaluated by performing several numerical verification simulations of wood components under different combinations of mechanical loading and moisture variation. Additionally, the flexibility and universality of the introduced model to predict the mechanical behavior of different species are demonstrated by the analysis of a hybrid wood element. Furthermore, the proposed numerical approach is validated by comparisons of computational evaluations with experimental results.

Mohammad Masoud Hassani; Falk K. Wittel; Stefan Hering; Hans J. Herrmann

2014-10-15T23:59:59.000Z

220

Woods on Private Estates  

Science Journals Connector (OSTI)

... of Estate Woodlands". Mr. Orde-Powlett first dealt with the value of the existing private woods to Great Britain during the Great War, pointing out that although the Forestry ... can afford to give adequate pay to the staff maintained. Since the majority of the private woodlands are not run on business lines they are under-staffed. If properly run, ...

1937-11-06T23:59:59.000Z

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Wood Energy in America  

Science Journals Connector (OSTI)

...hydroelectric, geothermal, and biomass sources...to the city's district energy system (7...of wood fuel for heating and cooling of buildings...and dependence on heating oil (21), but...transitions to AWC heating and cooling are technically...Third, expand district-energy systems...

Daniel deB. Richter; Jr.; Dylan H. Jenkins; John T. Karakash; Josiah Knight; Lew R. McCreery; Kasimir P. Nemestothy

2009-03-13T23:59:59.000Z

222

SMUD - Solar Water Heater Rebate Program | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heater Rebate Program Solar Water Heater Rebate Program SMUD - Solar Water Heater Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State California Program Type Utility Rebate Program Rebate Amount 500 - 1,500 per system, depending on energy savings Provider Sacramento Municipal Utility District The Sacramento Municipal Utility District's (SMUD) Solar Domestic Hot Water Program provides rebates and/or loan financing to customers who install solar water heating systems. The amount of the rebate depends on how much electricity the system will offset annually: * 800 - 1,399 kWh: $500 * 1,400 - 2,199 kWh: $1,000 * 2,200 kWh or greater: $1,500 . All solar water-heating units must meet standards set by the Solar Rating

223

FEMP Designated Product Assessment for Commercial Gas Water Heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

FEMP Designated Product Assessment for Commercial Gas Water Heaters FEMP Designated Product Assessment for Commercial Gas Water Heaters Title FEMP Designated Product Assessment for Commercial Gas Water Heaters Publication Type Report LBNL Report Number LBNL-5514E Year of Publication 2010 Authors Lutz, James D. Subsidiary Authors Energy Analysis Department Document Number LBNL-5514E Pagination 8 Date Published April 1 Publisher Lawrence Berkeley National Laboratory City Berkeley ISBN Number LBNL-5514E Abstract None Notes This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology, State, and Community Programs, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. Attachment Size PDF 240.22 KB Google Scholar BibTex RIS RTF XML Alternate URL: http://eetd.lbl.gov/node/50317

224

Savings Project: Insulate Your Water Heater Tank | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Savings Project: Insulate Your Water Heater Tank Savings Project: Insulate Your Water Heater Tank Savings Project: Insulate Your Water Heater Tank Addthis Project Level medium Energy Savings $20-$45 annually Time to Complete 1.5 hours Overall Cost $30 Insulate your hot water tank to save energy and money. | Photo courtesy of iStockphoto.com/glennebo Insulate your hot water tank to save energy and money. | Photo courtesy of iStockphoto.com/glennebo Just like insulating your walls or roof, insulating your hot water tank is an easy and inexpensive way to improve energy efficiency and save you money each month. If your water tank is new, it is likely already insulated. If you have an older hot water tank, check to see if it has insulation with an R-value of at least 24. If not, consider insulating your water tank, which

225

Experimental study of integrated collector storage solar water heaters  

Science Journals Connector (OSTI)

Three Integrated Collector Storage Solar Water Heaters (ICSSWH) have been designed, constructed and experimentally studied in comparison to a Flat Plate Thermosiphonic Unit (FPTU). Each of the ICS experimental models consists of one cylindrical tank horizontally mounted in a stationary symmetrical Compound Parabolic Concentrating (CPC) reflector trough. The main objective is the design and construction of low cost solar water heaters with improved thermal performance and lower possible depths. The experimental models can be mounted on horizontal as well as on inclined roofs by adopting the lowest possible depth. The results show that these solar devices perform more than effectively all year long. This could contribute significantly on the development of ICS type solar water heaters.

M. Souliotis; D. Chemisana; Y.G. Caouris; Y. Tripanagnostopoulos

2013-01-01T23:59:59.000Z

226

Outdoor Outfitter Gets Greener With Solar Water Heater | Department of  

Broader source: Energy.gov (indexed) [DOE]

Outdoor Outfitter Gets Greener With Solar Water Heater Outdoor Outfitter Gets Greener With Solar Water Heater Outdoor Outfitter Gets Greener With Solar Water Heater October 8, 2010 - 12:51pm Addthis L.L. Bean’s flagship store sees nearly 3 million visitors each year. The store now uses solar-heated water for showers, restrooms and two cafes. | Photo courtesy of L.L. Bean | L.L. Bean's flagship store sees nearly 3 million visitors each year. The store now uses solar-heated water for showers, restrooms and two cafes. | Photo courtesy of L.L. Bean | Lindsay Gsell L.L. Bean is known for its outdoor apparel- jackets, backpacks and cozy winter sweaters. However, the company does more than just dress for the outdoors, it also works to protect and preserve it. For nearly 100 years, L.L. Bean has been committed to environmental conservation and

227

Feedback regulated induction heater for a flowing fluid  

DOE Patents [OSTI]

A regulated induction heater for heating a stream of flowing fluid to a predetermined desired temperature. The heater includes a radiofrequency induction coil which surrounds a glass tube through which the fluid flows. A heating element consisting of a bundle of approximately 200 stainless steel capillary tubes located within the glass tube couples the output of the induction coil to the fluid. The temperature of the fluid downstream from the heating element is sensed with a platinum resistance thermometer, the output of which is applied to an adjustable porportional and integral feedback control circuit which regulates the power applied to the induction coil. The heater regulates the fluid temperature to within 0.005/sup 0/C at a flow rate of 50 cm/sup 3//sec with a response time of less than 0.1 second, and can accommodate changes in heat load up to 1500 watts.

Migliori, A.; Swift, G.W.

1984-06-13T23:59:59.000Z

228

Feedback regulated induction heater for a flowing fluid  

DOE Patents [OSTI]

A regulated induction heater for heating a stream of flowing fluid to a predetermined desired temperature. The heater includes a radiofrequency induction coil which surrounds a glass tube through which the fluid flows. A heating element consisting of a bundle of approximately 200 stainless steel capillary tubes located within the glass tube couples the output of the induction coil to the fluid. The temperature of the fluid downstream from the heating element is sensed with a platinum resistance thermometer, the output of which is applied to an adjustable proportional and integral feedback control circuit which regulates the power applied to the induction coil. The heater regulates the fluid temperature to within 0.005.degree. C. at a flow rate of 50 cm.sup.3 /second with a response time of less than 0.1 second, and can accommodate changes in heat load up to 1500 watts.

Migliori, Albert (Santa Fe, NM); Swift, Gregory W. (Los Alamos, NM)

1985-01-01T23:59:59.000Z

229

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

SciTech Connect (OSTI)

Residential water heating is a large source of energy use in California homes. This project took a life cycle approach to comparing tank and tankless water heaters in Northern and Southern California. Information about the life cycle phases was calculated using the European Union?s Methodology study for EcoDesign of Energy-using Products (MEEUP) and the National Renewable Energy Laboratory?s Life Cycle Inventory (NREL LCI) database. In a unit-to-unit comparison, it was found that tankless water heaters would lessen impacts of water heating by reducing annual energy use by 2800 MJ/year (16% compared to tank), and reducing global warming emissions by 175 kg CO2 eqv./year (18% reduction). Overall, the production and combustion of natural gas in the use phase had the largest impact. Total waste, VOCs, PAHs, particulate matter, and heavy-metals-to-air categories were also affected relatively strongly by manufacturing processes. It was estimated that tankless water heater users would have to use 10 more gallons of hot water a day (an increased usage of approximately 20%) to have the same impact as tank water heaters. The project results suggest that if a higher percentage of Californians used tankless water heaters, environmental impacts caused by water heating would be smaller.

Lu, Alison; McMahon, James; Masanet, Eric; Lutz, Jim

2008-08-13T23:59:59.000Z

230

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review ...  

Energy Savers [EERE]

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review Presenter: Tony Bouza, U.S. Department of Energy This...

231

Electric Blanket vs. Space Heater: #EnergyFaceoff Round 3 Heats...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Blanket vs. Space Heater: EnergyFaceoff Round 3 Heats Up Electric Blanket vs. Space Heater: EnergyFaceoff Round 3 Heats Up November 17, 2014 - 9:49am Q&A Which appliance do you...

232

Electric Blanket Delivers K.O. to Space Heater During #EnergyFaceoff...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Electric Blanket Delivers K.O. to Space Heater During EnergyFaceoff Round Three Electric Blanket Delivers K.O. to Space Heater During EnergyFaceoff Round Three November 19, 2014...

233

Numerical analysis of thermal-hydrological conditions in the single heater test at Yucca Mountain  

E-Print Network [OSTI]

Single Heater Test at Yucca Mountain, LBNL-39789, E.O. LawSingle Heater Test at Yucca Mountain Jens T. Birkholzer andwaste repository at Yucca Mountain. The heating phase of the

Birkholzer, Jens T.; Tsang, Yvonne W.

1998-01-01T23:59:59.000Z

234

Fuel Efficient Stoves for Darfur Camps of Internally DisplacedPersons - Report of Field Trip to North and South Darfur, Nov. 16 -Dec.17, 2005  

SciTech Connect (OSTI)

Approximately 2.2 million internally displaced persons (''IDPs'') in Darfur are living in dense camps scattered in arid areas with low fuelwood productivity. Unsustainable harvesting of fuelwood by the IDPs has created ever increasing zones of denudation, that now (in November 2005) have reached several kilometers from the camp boundaries. Leaving the safety of the camps to fetch fuelwood from farther and farther away imposes great risk and hardship on the IDP women. Three different metal fuel efficient stove (''FES'') designs were tested in Darfur IDP camps for their suitability to substantially reduce the fuelwood needs of IDPs. The mud-and-dung ''ITDG'' stoves being promoted under the current FES program were also examined and tested. A modified design of the ITDG mud-and-dung stove, ''Avi'', was developed, built and tested. Systematic informal surveys of IDP households were undertaken in North and South Darfur to understand the household parameters related to family size, food, fuel, cooking habits, cooking pots, expenditure on fuel, and preferences related to alternative ways to spend time/money if fuel could be saved. Surveys found that a significant fraction of families are missing meals for lack of fuel (50% in South Darfur, and 90% in the North Darfur camps visited by the mission). About 60% of women in South Darfur, and about 90% of women in North Darfur camps purchase fuelwood. Selling some of the food rations to purchase fuel to cook meals was significant (40%) in South Darfur and has become common (80%) in North Darfur. The LBNL mission found that two of the metal stoves and the mud-and-dung Avi can significantly reduce fuelwood consumption using the same fuel, pot, cooking methods, and food ingredients used by Darfur IDPs. The most suitable design for Darfur conditions would be a modified ''Tara'' stove. With training of the cooks in tending the fire, this stove can save 50% fuel for the IDPs. The stove costs less than $10 (US) to produce in Darfur, and saves fuelwood worth $160 annually at local market prices. For programmatic and administrative reasons, the LBNL mission do not recommend a mud-and-dung stove, for which control of quality and dimensional accuracy is expensive and cumbersome to administer, particularly in a rapid large rollout effort. A light metal stove, on the other hand, can be rapidly produced in large numbers locally in Darfur, with good quality control exercised on the material and dimensions of the stoves right at the workshop where it is produced. LBNL mission also recommends immediate trials of 50 Tara stoves in a pilot technical rollout, 500 Tara stoves in a pilot social rollout, in parallel with a technical effort to modify the Tara design to make it better suited for Darfur camp conditions. The mission also recommends a program for manufacturing, disseminating the metal stoves, and educating the IDPs in fuel-efficient cooking practices. Monitoring of the stove quality, dissemination effort and training should be an integral part of the program, with systematic summaries planned with 10,000, 50,000 and 100,000 stoves have been disseminated. In the above pilot rollouts as well as in the final implementation, it is important to continue to pay attention to training of the cooks in tending the cooking fire in the stoves, and offer continued social reinforcement to this training (e.g., through periodic competitions to cook normal meals with the least fuelwood use.)

Galitsky, Christina; Gadgil, Ashok; Jacobs, Mark; Lee, Yoo-Mi

2006-02-01T23:59:59.000Z

235

Modeling and Test-and-Rate Methods for Innovative Thermosiphon Solar Water Heaters: Preprint  

SciTech Connect (OSTI)

Conference paper regarding research in modeling and test-and-rate methods for thermosiphon solar domestic water heaters.

Burch, J.; Shoukas, G.; Brandemuhl, M.; Krarti, M.

2006-05-01T23:59:59.000Z

236

Field Testing of Pre-Production Prototype Residential Heat Pump Water Heaters  

Broader source: Energy.gov [DOE]

Provides and overview of field testing of 18 pre-production prototype residential heat pump water heaters

237

Conventional Storage Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Conventional Storage Water Heater Basics Conventional Storage Water Heater Basics Conventional Storage Water Heater Basics July 30, 2013 - 3:39pm Addthis Illustration showing the components of a storage water heater. On top of the tank are two thin pipes; one pipe is the hot water outlet, and the other is the cold water inlet. A large pipe in the middle is called a vent pipe. A pressure/temperature relief valve is also on top of the tank and is connected to an open pipe that runs down the side of the tank. Another valve near the bottom of the outside of the tank is the thermostat and gas valve. A cutout shows the parts inside the tank, which include a large tube called a flue tube/heat exchanger. Inside this tube is a jagged insert called a flue baffle. Beside the flue tube/heat exchanger is a thin tube called the anode rod. At the bottom of the tank is a gas burner, and beneath the burner are combustion air openings.

238

Silicon microbench heater elements for packaging opto-electronic devices  

SciTech Connect (OSTI)

Examples are presented of the application of Lawrence Livermore National Laboratory`s expertise in photonics packaging. Several examples of packaged devices will be described. Particular attention is given to silicon microbenches incorporating heaters and their use in semiconductor optical amplifier fiber pigtailing and packaging.

Combs, R.; Keiser, P.; Kleint, K.; Pocha, M.; Patterson, F.; Strand, O.T.

1995-09-01T23:59:59.000Z

239

Covered Product Category: Residential Heat Pump Water Heaters  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including residential heat pump water heaters, which are an ENERGY STAR-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

240

Covered Product Category: Residential Electric Resistance Water Heaters  

Broader source: Energy.gov [DOE]

FEMP sets Federal efficiency requirements and provides acquisition guidance across a variety of product categories, including residential electric resistance water heaters. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters  

SciTech Connect (OSTI)

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

Sparn, B.; Hudon, K.; Christensen, D.

2014-06-01T23:59:59.000Z

242

Applications Tests of Commercial Heat Pump Water Heaters  

E-Print Network [OSTI]

Field application tests have been conducted on three 4 to 6-ton commercial heat pump water heater systems in a restaurant, a coin-operated laundry, and an office building cafeteria in Atlanta. The units provide space cooling while rejecting heat...

Oshinski, J. N..; Abrams, D. W.

1987-01-01T23:59:59.000Z

243

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters  

SciTech Connect (OSTI)

This report discusses how a significant opportunity for energy savings is domestic hot water heating, where an emerging technology has recently arrived in the U.S. market: the residential integrated heat pump water heater. A laboratory evaluation is presented of the five integrated HPWHs available in the U.S. today.

Sparn, B.; Hudon, K.; Christensen, D.

2011-09-01T23:59:59.000Z

244

Covered Product Category: Residential Gas Storage Water Heaters  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance across a variety of product categories, including gas storage water heaters, which are an ENERGY STAR-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

245

Novel Column Heater for Fast Capillary Gas Chromatography  

Science Journals Connector (OSTI)

......expected advantage of radial heating with the coaxial heater...with other "coated" heating elements, differences...Louisiana light crude oil; 3 m 0.1 mm phenyl...expansion coefficient, and price imposed substantial practical...existing standard column heating technology. Thus, chromatographic......

E.U. Ehrmann; H.P. Dharmasena; K. Carney; E.B. Overton

1996-12-01T23:59:59.000Z

246

Restoration of Refinery Heaters Using the Technique of Prefabricated Ceramic Fiber Lined Panels  

E-Print Network [OSTI]

Refinery heater fuel requirements often represent 50% of a units operating cost. A one percent change in the efficiency of a heater firing 100 MBtu/hr amounts to more than $25,000 per year. Heater efficiency is influenced by casing hot spots, air...

Sento, H. D.

1981-01-01T23:59:59.000Z

247

Development of a Market Optimized Condensing Gas Water Heater  

SciTech Connect (OSTI)

This program covered the development of a market optimized condensing gas water heater for residential applications. The intent of the program was to develop a condensing design that minimized the large initial cost premium associated with traditional condensing water heater designs. Equally important was that the considered approach utilizes design and construction methods that deliver the desired efficiency without compromising product reliability. Standard condensing water heater approaches in the marketplace utilize high cost materials such as stainless steel tanks and heat exchangers as well as expensive burner systems to achieve the higher efficiencies. The key in this program was to develop a water heater design that uses low-cost, available components and technologies to achieve higher efficiency at a modest cost premium. By doing this, the design can reduce the payback to a more reasonable length, increasing the appeal of the product to the marketplace. Condensing water heaters have been in existence for years, but have not been able to significantly penetrate the market. The issue has typically been cost. The high purchase price associated with existing condensing water heaters, sometimes as much as $2000, has been a very difficult hurdle to overcome in the marketplace. The design developed under this program has the potential to reduce the purchase price of this condensing design by as much as $1000 as compared to traditional condensing units. The condensing water heater design developed over the course of this program led to an approach that delivered the following performance attributes: 90%+ thermal efficiency; 76,000 Btu/hr input rate in a 50 gallon tank; First hour rating greater than 180 gph; Rapid recovery time; and Overall operating condition well matched to combination heat and hot water applications. Over the final three years of the program, TIAX worked very closely with A.O. Smith Water Products Company as our commercial partner to optimize the design for manufacturing. This work included the initiation of a large field testing program (over 125 units) and an in-depth reliability program intended to minimize the risks associated with a new product introduction. At the time of this report, A.O. Smith plans to introduce this product to the marketplace in the early 2006 time period.

Peter Pescatore

2006-01-11T23:59:59.000Z

248

Dynamic loss properties of wood  

Science Journals Connector (OSTI)

Internal friction and dielectric lossmeasurements have been made on whole wood on cellulose and on lignin. A prominent ? peak is seen at 200 K for frequencies around 1 Hz. This peak shifts to lower temperatures (near 160 K) when wood is heated to 475 K. We propose that this shift signifies molecular changes characteristic of the first stages of coalification of wood and lignin. Additional comparisons are made with the macromolecular structure of amber oil shale and synthetic polymers.

C. A. Wert; Manford Weller; Dan Caulfield

1984-01-01T23:59:59.000Z

249

SOME POV-RAY TEXTURES AND COLORS T_Wood1 to T_Wood35  

E-Print Network [OSTI]

SOME POV-RAY TEXTURES AND COLORS WOODS.INC T_Wood1 to T_Wood35 STONES.INC T_Stone1 to T_Stone44Pink DarkPurple NeonBlue CoolCopper MandarinOrange LightWood MediumWood DarkWood SpicyPink Semi

Lee, Carl

250

Isocyanate-Wood Adhesive Bond  

Science Journals Connector (OSTI)

We have used infrared spectroscopy to study the reaction between phenyl isocyanate and glucose, cellulose, lignin, and wood. In the latter instance we have investigated oven-dried...

Weaver, F William; Owen, Noel L

1995-01-01T23:59:59.000Z

251

Placing technology : examining the emerging use of solar water heaters in Oaxaca, Mexico: Examining the emerging use of solar water heaters in Oaxaca, Mexico.  

E-Print Network [OSTI]

??This study is an examination of the (broadly envisioned) process that has led to the emerging use of solar water heaters in Oaxaca de Jua?rez, (more)

Shannon, Steven Jacob

2011-01-01T23:59:59.000Z

252

Three-phase heaters with common overburden sections for heating subsurface formations  

DOE Patents [OSTI]

A heating system for a subsurface formation is described. The heating system includes three substantially u-shaped heaters with first end portions of the heaters being electrically coupled to a single, three-phase wye transformer and second end portions of the heaters being electrically coupled to each other and/or to ground. The three heaters may enter the formation through a first common wellbore and exit the formation through a second common wellbore so that the magnetic fields of the three heaters at least partially cancel out in the common wellbores.

Vinegar, Harold J. (Bellaire, TX)

2012-02-14T23:59:59.000Z

253

Successful biomass (wood pellets ) implementation in  

E-Print Network [OSTI]

of primary energy in Estonia ! Wood fuels production ! Pellet firing projects in Estonia ­ SIDA Demo East Production of wood fuels in Estonia in 2002 Regional Energy Centres in Estonia Wood pellets production

254

Causes and Control of Wood Decay,  

E-Print Network [OSTI]

1 Causes and Control of Wood Decay, Degradation & Stain #12;2 Contents Moisture .................................................................................3 Wood Degradation: Causes and Control..............................4 Weathering......................................................................................................4 Naturally Decay-resistant Species...........................................................5 Wood

255

Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Carbon Dioxide-Based Carbon Dioxide-Based Heat Pump Water Heater Research Project to someone by E-mail Share Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Facebook Tweet about Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Twitter Bookmark Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Google Bookmark Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Delicious Rank Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on Digg Find More places to share Building Technologies Office: Carbon Dioxide-Based Heat Pump Water Heater Research Project on AddThis.com...

256

Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Gas-Fired Absorption Gas-Fired Absorption Heat Pump Water Heater Research Project to someone by E-mail Share Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Facebook Tweet about Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Twitter Bookmark Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Google Bookmark Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Delicious Rank Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on Digg Find More places to share Building Technologies Office: Gas-Fired Absorption Heat Pump Water Heater Research Project on AddThis.com...

257

WRITTEN TESTIMONY OF DR. ROBERT J. WOOD  

E-Print Network [OSTI]

WRITTEN TESTIMONY OF DR. ROBERT J. WOOD DIRECTOR OF THE COOPERATIVE OXFORD LABORATORY NATIONAL Robert Wood, Director of the Cooperative Oxford Laboratory, a cooperative scientific research laboratory

258

Wood, Wisconsin: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

t":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":"" Display map Wood is a town in Wood County, Wisconsin.1 References US Census Bureau Incorporated...

259

Creating Value Wood Products Industry  

E-Print Network [OSTI]

and an information dissemination plan. The program areas are Industrial Process Improvement, Environmental Assessment1 Creating Value for the Wood Products Industry Creating Value for the Wood Products Industry Louisiana Forest Products Development Center #12;2 Louisiana is blessed with quality timberland

260

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Performance Performance Evaluation of Residential Integrated Heat Pump Water Heaters B. Sparn, K. Hudon, and D. Christensen Technical Report NREL/TP-5500-52635 September 2011 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308 Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters B. Sparn, K. Hudon, and D. Christensen Prepared under Task Nos. WTN9.1000, ARRB.2204 Technical Report NREL/TP-5500-52635 September 2011 NOTICE This report was prepared as an account of work sponsored by an agency of the United States government.

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Daniel Wood | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Wood Wood About Us Daniel Wood - Data Integration Specialist Daniel Wood Daniel Wood is the Data Visualization and Cartographic Specialist in the Office of Public Affairs at the Department of Energy. He develops creative and interactive ways of viewing the Energy Department's vast array of data. You can check out some of his work here. Prior to joining the Energy.gov team, Daniel worked at a large PR firm in Washington, D.C, doing web development and technical project management. Daniel is a graduate of Boston University but a true Philadelphian at heart. On his off days you are likely to find him exploring new neighborhoods on his bike or hanging out with the awesome kids over at Little Lights Urban Ministries. Most Recent The History of the Light Bulb November 22

262

Advances in the Research of Heat Pump Water Heaters  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Renewable Energy Resources and a Greener Future Vol.VIII-12-2 1 Advances in the Research of Heat Pump Water Heaters Shangli Shan Dandan Wang Ruixiang Wang Master Master Professor Beijing...) [21] Wang sui-lin . Affection on fin-and-tube Heat Exchanger's Properties by non azeotropic mixtures[J] . Fluid machinery , 1996 , 24 (5) [22] Ge run-ting . Foundation of Dynamic Parameter Model and Theoritical Calculation of Evaporator...

Shan, S.; Wang, D.; Wang, R.

2006-01-01T23:59:59.000Z

263

U. K. consortium Stirling engine regenerator effectiveness and heater performance  

SciTech Connect (OSTI)

This paper covers results of measurements of effectiveness of regenerator materials by use of a dynamic test rig. The rig enables measurements to be made of enthalpy flux through the regenerator under simulated Stirling engine conditions of fluid flow and heat transfer. The paper also discusses the design and operation of the 60 kw heat-pipe heater head of the U.K. Consortium Stirling engine.

Rice, G.; Dadd, M.W.; Jones, J.D.; Thonger, J.

1983-08-01T23:59:59.000Z

264

Chiller-heater unit nets building 2-yr payback  

SciTech Connect (OSTI)

A 500-ton double-absorption Hitachi Paraflow chiller-heater that switches from purchased steam to natural gas will reduce a Manhattan office building's energy costs by 55% and achieve a two-year payback. The new system replaces a steam-powered, single-stage absorption chiller. By reusing heat in a second-stage generator, the Hitachi unit uses only half as many Btus per ton as a conventional chiller. (DCK)

Duffy, J.

1983-05-09T23:59:59.000Z

265

Materials performance in fluidized-bed air heaters  

SciTech Connect (OSTI)

Development of cogeneration systems that involve combustion of coal in a fluidized bed and use of air heaters to generate hot air for turbine systems has been in progress for a number of years. The US Department of Energy (DOE) sponsored the Atmospheric Fluidized-Bed Cogeneration Air Heater Experiment (ACAHE) to assess the performance of various heat exchanger materials and establish confidence in the resultant designs of fluidized-bed-combustion air heater systems. Westinghouse Electric Corporation, in association with Babcock & Wilcox, Foster Wheeler, and ABB/Combustion Engineering, prepared specifications and hardware for the ACAHE. Argonne National Laboratory, through a contract with the Rocketdyne Division of Rockwell International, conducted tests in the DOE 1.8 {times} 1.8 m atmospheric fluidized-bed combustion facility in El Segundo, California. This paper presents an assessment of the materials performance in fluidized bed environments and examines guidelines for materials selection on the basis of corrosion resistance in air and in combustion environments, mechanical properties, fabricability/thermal stability, and cost.

Natesan, K.; Podolski, W.

1991-12-01T23:59:59.000Z

266

Materials performance in fluidized-bed air heaters  

SciTech Connect (OSTI)

Development of cogeneration systems that involve combustion of coal in a fluidized bed and use of air heaters to generate hot air for turbine systems has been in progress for a number of years. The US Department of Energy (DOE) sponsored the Atmospheric Fluidized-Bed Cogeneration Air Heater Experiment (ACAHE) to assess the performance of various heat exchanger materials and establish confidence in the resultant designs of fluidized-bed-combustion air heater systems. Westinghouse Electric Corporation, in association with Babcock Wilcox, Foster Wheeler, and ABB/Combustion Engineering, prepared specifications and hardware for the ACAHE. Argonne National Laboratory, through a contract with the Rocketdyne Division of Rockwell International, conducted tests in the DOE 1.8 {times} 1.8 m atmospheric fluidized-bed combustion facility in El Segundo, California. This paper presents an assessment of the materials performance in fluidized bed environments and examines guidelines for materials selection on the basis of corrosion resistance in air and in combustion environments, mechanical properties, fabricability/thermal stability, and cost.

Natesan, K.; Podolski, W.

1991-12-01T23:59:59.000Z

267

Electric Water Heater Modeling and Control Strategies for Demand Response  

SciTech Connect (OSTI)

Abstract Demand response (DR) has a great potential to provide balancing services at normal operating conditions and emergency support when a power system is subject to disturbances. Effective control strategies can significantly relieve the balancing burden of conventional generators and reduce investment on generation and transmission expansion. This paper is aimed at modeling electric water heaters (EWH) in households and tests their response to control strategies to implement DR. The open-loop response of EWH to a centralized signal is studied by adjusting temperature settings to provide regulation services; and two types of decentralized controllers are tested to provide frequency support following generator trips. EWH models are included in a simulation platform in DIgSILENT to perform electromechanical simulation, which contains 147 households in a distribution feeder. Simulation results show the dependence of EWH response on water heater usage . These results provide insight suggestions on the need of control strategies to achieve better performance for demand response implementation. Index Terms Centralized control, decentralized control, demand response, electrical water heater, smart grid

Diao, Ruisheng; Lu, Shuai; Elizondo, Marcelo A.; Mayhorn, Ebony T.; Zhang, Yu; Samaan, Nader A.

2012-07-22T23:59:59.000Z

268

Wood would burn  

Science Journals Connector (OSTI)

Absract In view of the world-wide problem of energy sustainability and greenhouse gas production (carbon dioxide), it is timely to review the issues involved in generating heat and power from all fuels and especially new (to the UK) solid fuels, including high moisture fuels such as wood, SRF, oil shale, tar sands and brown coal, which will become major international fuels as oil and gas become depleted. The combustion properties of some of these materials are significantly different from traditional coal, oil and gas fuels, however the technology proposed herein is also applicable to these conventional fuels. This paper presents some innovative combustion system options and the associated technical factors that must be considered for their implementation. For clarity of understanding, the novel concepts will be largely presented in terms of a currently developing solid fuel market; biomass wood chips. One of the most important characteristics of many solid fuels to be used in the future (including oil shale and brown coal) is their high moisture content of up to 60%. This could be removed by utilising low grade waste heat that is widely available in industry to dry the fuel and thus reduce transport costs. Burning such dried wood for power generation also increases the energy available from combustion and thus acts as a thermal transformer by upgrading the low grade heat to heat available at combustion temperatures. The alternative approach presented here is to recover the latent heat by condensing the extrinsic moisture and the water formed during combustion. For atmospheric combustion, the temperature of the condensed combustion products is below the dew point at about 5565C and is only suitable for recovery in an efficient district heating system. However, in order to generate power from the latent heat, the condensation temperature must be increased to the level where the heat can be used in the thermodynamic power cycle. This can be achieved by increasing the combustion pressure to above 80bar, resulting in the recovered latent heat being available at more than 200C. It can then be used to increase the cycle efficiency by about 15% by pre-heating the boiler water and/or combustion air etc. A further advantage is that the high pressure of the combustion gases also reduces the superheater tube stress since it can balance the steam pressure. The key advantage of this high pressure flue gas is that it is above the pressure at which carbon dioxide condenses to a liquid or supercritical gas at atmospheric temperature. Thus when used with oxy-fuel combustion, the carbon dioxide flue gas from which the moisture has been condensed can be cooled to atmospheric temperature and the supercritical CO2 can be fed directly into the pipes leading to the sequestration site. An important consideration of these strategies is to ensure that non-condensable gases in the exhaust, including oxygen and nitrogen, do not adversely affect the condensation processes. When oxy-fuel combustion is used, the flame temperature must be moderated by a cool diluent. Recycled carbon dioxide is often proposed for this duty. However, since the latent heat is recovered, the moisture or even additional water can fulfil this role. This latter option may be advantageous since it is more efficient to pump wood chip fuel in water into the high pressure zone rather than feed solid wood particles. Surplus water can be simply drained and the wet wood chips are a good fuel when the latent heat of the moisture in the fuel gases is recovered into the power cycle. Bearing in mind that it is much more efficient to pump a liquid to high pressure than to compress the same material as a gas, indicates that cryogenic oxygen is a suitable material to use for an efficient power station that generates energy from biomass (or other fuels such as coal etc). Finally, combustion of the hydrogen from the watergas reaction with oxygen allows the steam temperature in the turbine to be increased to the gas-turbine engine range of 10001400C an

Jim Swithenbank; Qun Chen; Xiaohui Zhang; Vida Sharifi; Mohamed Pourkashanian

2011-01-01T23:59:59.000Z

269

Wood River Levee Reconstruction, Madison County, IL  

E-Print Network [OSTI]

Wood River Levee Reconstruction, Madison County, IL 25 October 2006 Abstract: The recommended plan provides for flood damage reduction and restores the original degree of protection of the Wood River Levee-federal sponsor is the Wood River Drainage and Levee District. The Wood River Levee System was authorized

US Army Corps of Engineers

270

Original article Growth stresses in tension wood  

E-Print Network [OSTI]

Original article Growth stresses in tension wood: role of microfibrils and lignification T Okuyama the growth stress generation in the region of normal and tension woods. growth stress/ tension wood in normal and ten- sion wood. The compressive stress from the deposition of lignin controls the level

Paris-Sud XI, Université de

271

Global Timber and Wood Products Market Update -a news brief from Wood Resources International LLC  

E-Print Network [OSTI]

Global Timber and Wood Products Market Update - a news brief from Wood Resources International LLC to be the major destination for Latin American wood chips, reports the Wood Resource Quarterly In late 2011 wood chips from only three countries: Vietnam, Indonesia and Australia, who together shipped 1

272

West Virginian No Longer Worried About Family's Safety | Department of  

Broader source: Energy.gov (indexed) [DOE]

Virginian No Longer Worried About Family's Safety Virginian No Longer Worried About Family's Safety West Virginian No Longer Worried About Family's Safety April 2, 2010 - 2:29pm Addthis Joshua DeLung When the mountain winters hit for the last 12 years, Michael Shepard and his family had only a wood stove in their house for heat, plus a few kerosene heaters when the stove didn't do the trick. Michael's diagnosis as a diabetic, coupled with a shoulder injury, left him disabled, resulting in his early retirement. Relying on a wood stove with a serious shoulder injury meant getting heat in Michael's Bluefield, W.Va., home was a struggle. "It was cold, just using wood heat, and my wife had to carry it in for me," he says. After applying for and receiving weatherization assistance from Community Action of South Eastern West Virginia last year, though, his lifestyle at

273

Structure-Infesting Wood-Boring Beetles  

E-Print Network [OSTI]

everal kinds of beetles damage stored wood, structural timbers and other wood products. The tunneling activities E-394 03/06 Structure-Infesting Wood-Boring Beetles John A. Jackman* S *Professor and Extension Entomologist, The Texas A... at these locations. Other signs of an infestation include stained wood or a blistering appearance on the wood surface caused by larvae tunneling just below the surface. Less commonly, immature beetles produce audible rasping or ticking sounds while chewing...

Jackman, John A.

2006-03-28T23:59:59.000Z

274

Testing and analysis of the Semiscale Mod-1 heater rod design  

SciTech Connect (OSTI)

The use of electrically heated nuclear fuel rod simulators in the Semiscale Program is traced from a historical viewpoint. The design of the Semiscale Mod-1 electrical heater rod and core simulator is discussed. Heater rod thermal response during transient thermal-hydraulic depressurization experiments conducted in the Mod-1 system, and analysis techniques and tests conducted to help quantify heater rod characteristics and behavior are presented.

Larson, T.K.

1980-01-01T23:59:59.000Z

275

Integrated Industrial Wood Chip Utilization  

E-Print Network [OSTI]

The sources of supply of wood residues for energy generation are described and the rationale for exploring the potential available from forest harvesting is developed. Details of three industrial-scale projects are presented and the specific...

Owens, E. T.

1984-01-01T23:59:59.000Z

276

Treatment of Wood Preserving Wastewater  

E-Print Network [OSTI]

The wastewater produced by the wood preserving industry presents a difficult problem to treat economically. A review of the literature indicates the size of the industry has limited the pursuit of an orderly and economic solution. Atmospheric...

Reynolds, T. D.; Shack, P. A.

277

Textile Drying Via Wood Gasification  

E-Print Network [OSTI]

TEXTILE DRYING VIA WOOD GASIFICATION Thomas F. ;McGowan, Anthony D. Jape Georgia Institute of Technology Atlanta, Georgia ABSTRACT This project was carried out to investigate the possibility of using wood gas as a direct replacement... for dryers. In addition to the experimental program described above, the DOE grant covered two other major areas. A survey of the textile industry was made to assess the market for gasification equip ment. The major findings were that a large amount...

McGowan, T. F.; Jape, A. D.

1983-01-01T23:59:59.000Z

278

HEATER TEST PLANNING FOR THE NEAR SURFACE TEST FACILITY AT THE HANFORD RESERVATION  

E-Print Network [OSTI]

Heater Experiment at Hanford. Berkeley, Lawre ;e BerkeleyTest Facility, Hole DC-11, Hanford Reservation. Prepared forof Gable Mountain Basalt Cores, Hanford Nuclear Reservation.

DuBois, A.

2010-01-01T23:59:59.000Z

279

Electric Blanket Delivers K.O. to Space Heater During #EnergyFaceoff Round Three  

Broader source: Energy.gov [DOE]

#EnergyFaceoff round three goes to the electric blanket, see how much more money it can save you over a space heater!

280

Development of solar air heaters & thermal energy storage system for drying applications in food processing industries.  

E-Print Network [OSTI]

??In the present work, the author has designed and developed all types of solar air heaters called porous and nonporous collectors. The developed solar air (more)

Sreekumar, A

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

DOE Publishes Notice of Proposed Rulemaking for Direct Heating Equipment and Pool Heater Test Procedures  

Broader source: Energy.gov [DOE]

The Department of Energy has published a notice of proposed rulemaking regarding test procedures for direct heating equipment and pool heaters.

282

Sustainable Energy Resources for Consumers (SERC)- On-Demand Tankless Water Heaters  

Broader source: Energy.gov [DOE]

This presentation, aimed at Sustainable Energy Resources for Consumers (SERC) grantees, provides information on Monitoring Checklists for the installation of On-Demand Tankless Water Heaters.

283

A model for improvement of water heating heat exchanger designs for residential heat pump water heaters.  

E-Print Network [OSTI]

??Heat pump water heaters are a promising technology to reduce energy use and greenhouse gas emissions. A key component is the water heating heat exchanger. (more)

Weerawoot, Arunwattana

2010-01-01T23:59:59.000Z

284

An Evaluation of the Water Heater Load Potential for Providing Regulation Service  

SciTech Connect (OSTI)

This paper investigates the possibility of providing aggregated regulation services with small loads, such as water heaters or air conditioners. A direct-load control algorithm is presented to aggregate the water heater load for the purpose of regulation. A dual-element electric water heater model is developed, which accounts for both thermal dynamics and users water consumptions. A realistic regulation signal was used to evaluate the number of water heaters needed and the operational characteristics of a water heater when providing 2-MW regulation service. Modeling results suggest that approximately 33,333 water heaters are needed to provide a 2-MW regulation service 24 hours a day. However, if water heaters only provide regulation from 6:00 to 24:00, approximately 20,000 will be needed. Because the control algorithm has considered the thermal setting of the water heater, the customer comfort is obstructed little. Therefore, the aggregated regulation service provided by water heater loads can become a major source of revenue for load-service entities when the smart grid enables the direct load control.

Kondoh, Junji; Lu, Ning; Hammerstrom, Donald J.

2011-08-31T23:59:59.000Z

285

Annual Operating Characteristics of Solar Central Water Heater System Assisted by Heat Pump  

Science Journals Connector (OSTI)

The solar central water heater (SCWH) could supply ... massive users effectively and reliably. A SCWH assisted by heat pump (SCWHP) was proposed...

Wei Hu; Zhaolin Gu; Shiyu Feng; Xiufeng Gao

2009-01-01T23:59:59.000Z

286

Solar Hot Water Heater Augmented with PV-TEM Heat Pump.  

E-Print Network [OSTI]

??Solar assisted heat pumps (SAHPs) can provide higher collector efficiencies and solar fractions when compared against standard solar hot water heaters. Vapour compression (VC) heat (more)

PRESTON, NATHANIEL

287

Energy Efficiency Design Options for Residential Water Heaters: Economic Impacts on Consumers  

E-Print Network [OSTI]

as conventional electric resistance water heaters. Atwo technologies: (1) an electric resistance storage waterin heat pump or in electric resistance mode. The electric

Lekov, Alex

2011-01-01T23:59:59.000Z

288

Coextruded Polyethylene and Wood-Flour Composite: Effect of Shell Thickness, Wood Loading, and Core  

E-Print Network [OSTI]

Coextruded Polyethylene and Wood-Flour Composite: Effect of Shell Thickness, Wood Loading, and Core recycled polyethylene and wood-flour composites with core­shell structure were manufactured using a pilot

289

Economic Analysis of Solar Water Heaters in GuangZhou  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Policy for Energy Efficiency and Comfort, Vol.VII-4-4 Economic Analysis of Solar Water Heaters in GuangZhou Ying Wang LiHua Zhao Graduated Student Associate Professor School of Architecture, South China... and lasting from a social benefit point of view in order to sustainable develop and ICEBO2006, Shenzhen, China Policy for Energy Efficiency and Comfort, Vol.VII-4-4 benefit our offspring. REFERENCES [1] Yi Yun, ShanMing Wang. Market insight of solar...

Wang, Y.; Zhao, L.

2006-01-01T23:59:59.000Z

290

Eleana near-surface heater experiment final report  

SciTech Connect (OSTI)

This report summarizes the results of a near-surface heater experiment operated at a depth of 23 m in argillite within the Eleana Formation on the Nevada Test Site (NTS). The test geometrically simulated emplacement of a single canister of High-Level Waste (HLW) and was operated at a power level of 2.5 kW for 21 days, followed by 3.8 kW to 250 days, when the power was turned off. Below 85 to 100{sup 0}C, there was good agreement between modeled and measured thermal results in the rock and in the emplacement hole, except for transient transport of water in the heater hole. Above 100{sup 0}C, modeled and measured thermal results increasingly diverged, indicating that the in-situ rock-mass thermal conductivity decreased as a result of dehydration more than expected on the basis of matrix properties. Correlation of thermomechanical modeling and field results suggests that this decrease was caused by strong coupling of thermal and mechanical behavior of the argillite at elevated temperatures. No hole-wall decrepitation was observed in the experiment; this fact and the codrrelation of modeled and measured results at lower temperatures indicate that there is no a priori reason to eliminate argillaceous rocks from further consideration as a host rock for nuclear wastes.

Lappin, A R; Thomas, R K; McVey, D F

1981-04-01T23:59:59.000Z

291

The conservation of waterlogged wood using sucrose  

E-Print Network [OSTI]

to the major axis of the wood. The tubular structure of wood cells expedites the movement of water vapor along the grain. Water vapor will move 12 to 15 times faster along the grain than it does across it. In a cube shaped piece of wood much more water... to the major axis of the wood. The tubular structure of wood cells expedites the movement of water vapor along the grain. Water vapor will move 12 to 15 times faster along the grain than it does across it. In a cube shaped piece of wood much more water...

Parrent, James Michael

2012-06-07T23:59:59.000Z

292

Table 3.6 Selected Wood and Wood-Related Products in Fuel Consumption, 2010;  

U.S. Energy Information Administration (EIA) Indexed Site

Table 3.6 Selected Wood and Wood-Related Products in Fuel Consumption, 2010; Table 3.6 Selected Wood and Wood-Related Products in Fuel Consumption, 2010; Level: National and Regional Data; Row: Selected NAICS Codes; Column: Energy Sources; Unit: Trillion Btu. Wood Residues and Wood-Related Pulping Liquor Wood Byproducts and NAICS or Biomass Agricultural Harvested Directly from Mill Paper-Related Code(a) Subsector and Industry Black Liquor Total(b) Waste(c) from Trees(d) Processing(e) Refuse(f) Total United States 311 Food 0 44 43 * * 1 311221 Wet Corn Milling 0 1 1 0 0 0 312 Beverage and Tobacco Products 0 1 0 0 1 0 321 Wood Products 0 218 * 13 199 6 321113 Sawmills 0 100 * 5 94 1 3212 Veneer, Plywood, and Engineered Woods 0 95 * 6 87 2 321219 Reconstituted Wood Products 0 52 0 6 46 1 3219 Other Wood Products

293

Energy Cost Calculator for Electric and Gas Water Heaters | Department of  

Broader source: Energy.gov (indexed) [DOE]

Electric and Gas Water Heaters Electric and Gas Water Heaters Energy Cost Calculator for Electric and Gas Water Heaters October 8, 2013 - 2:26pm Addthis Vary equipment size, energy cost, hours of operation, and /or efficiency level. INPUT SECTION Input the following data (if any parameter is missing, calculator will set to default value). Defaults Type of Water Heater Electric Gas Electric Average Daily Usage (gallons per day)* gallons 64* Energy Factor† 0.92 (electric) 0.61 (gas) Energy Cost $ / kWh $0.06 per kWh $.60 per therm Quantity of Water Heaters to be Purchased unit(s) 1 unit * See assumptions for various daily water use totals. † The comparison assumes a storage tank water heater as the input type. To allow demand water heaters as the comparison type, users can specify an input EF of up to 0.85; however, 0.66 is currently the best available EF for storage water heaters.

294

Selecting a New Water Heater You have a lot to consider when selecting a  

E-Print Network [OSTI]

the water heater's annual operation costs but also its size and energy efficiency. Natural gas, oil or tank water heater operates by releasing hot water from the top of the tank when the hot water tap is turned on. The hot water is released into the hot water line. As the hot water leaves the tank, cold

295

Tankless water heaters fill the bill at fast-food restaurants  

SciTech Connect (OSTI)

This article explains why Kentucky Fried Chicken has installed a PH-24 water heater. The tankless water heater meets the restaurant's criteria for space spacing, flow rates, certification and availability, and money saving efficiency. This article describes the system and its advantages.

Not Available

1988-02-01T23:59:59.000Z

296

Wood-Composites Industry Benefits from ALS Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Wood-Composites Industry Benefits from ALS Research Wood-Composites Industry Benefits from ALS Research Print Thursday, 25 October 2012 10:44 paris-wood composites Wood scientist...

297

PRELIMINARY THERMAL AND THERMOMECH-ANICAL MODELING FOR THE NEAR SURFACE TEST FACILITY HEATER EXPERIMANTS AT HANFORD: Appendix D  

E-Print Network [OSTI]

Heater Experiments at Hanford V O L U M E II (Appendix D) TENG-48 and for Rockwell Hanford Operations a Department ofFACILITY HEATER EXPERIMENTS AT HANFORD Volume 2 (Appendix D)

Chan, T.

2011-01-01T23:59:59.000Z

298

Spatially resolved temperature and heat flux measurements for slow evaporating droplets heated by a microfabricated heater array  

E-Print Network [OSTI]

The evaporation phenomenon of a liquid droplet was investigated by using microfabricated heaters. All 32 microheaters were designed to have the same resistance. Gold microheaters worked both as temperature indicators and as heaters. The first...

Paik, Sokwon

2006-08-16T23:59:59.000Z

299

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

300

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Building America Top Innovations Hall of Fame Profile … Tankless Gas Water Heater Performance  

Broader source: Energy.gov (indexed) [DOE]

Incorporating tankless water heaters was one Incorporating tankless water heaters was one of many energy-efficiency recommendations Building America's research team IBACOS had for San Antonio builder Imagine Homes. Although tankless gas water heaters should save approximately 33% on hot water heating compared to a conventional storage water heater, actual energy savings vary significantly based on individual draw volume. Above 10 gallons per draw, the efficiency approaches the rated energy factor. The greatest savings occur at a daily use quantity of about 50 gallons. BUILDING AMERICA TOP INNOVATIONS HALL OF FAME PROFILE INNOVATIONS CATEGORY: 1. Advanced Technologies and Practices 1.2 Energy Efficient Components Tankless Gas Water Heater Performance As improved thermal enclosures dramatically reduce heating and cooling loads,

302

Enhancement of Heat Transfer in an Artificially Roughened Solar Air Heater  

E-Print Network [OSTI]

Abstract: solar air heater is one of the basic equipment through which solar energy is converted into thermal energy. Solar air heaters, because of their simple in design, are cheap and most widely used collection devices of solar energy. The thermal efficiency of a solar air heater is significantly low because of the low value of the convective heat transfer coefficient between the absorber plate and the air, leading to high absorber plate temperature and high heat losses to the surroundings. This paper presents the study of heat transfer in a solar air heater by using Computational Fluid Dynamics (CFD). The effect of Reynolds number on Nusselt number is investigated. A commercial finite volume package ANSYS FLUENT 12.1 is used to analyze and visualize the nature of the flow across the duct of a solar air heater.

unknown authors

303

Gas-Fired Absorption Heat Pump Water Heater Research Project | Department  

Broader source: Energy.gov (indexed) [DOE]

Emerging Technologies » Gas-Fired Absorption Heat Pump Water Emerging Technologies » Gas-Fired Absorption Heat Pump Water Heater Research Project Gas-Fired Absorption Heat Pump Water Heater Research Project The U.S. Department of Energy (DOE) is currently conducting research into carbon gas-fired absorption heat pump water heaters. This project will employ innovative techniques to increase water heating energy efficiency over conventional gas storage water heaters by 40%. Project Description This project seeks to develop a natural gas-fired water heater using an absorption heat. The development effort is targeting lithium bromide aqueous solutions as a working fluid in order to avoid the negative implications of using more toxic ammonia. Project Partners Research is being undertaken through a Cooperative Research and Development

304

Categorical Exclusion for Wood Pole  

Broader source: Energy.gov (indexed) [DOE]

Wood Pole Wood Pole Replacement at two structures (11/6 & 11/9) located along the Oracle-Tucson 115-kV Transmission Line, in Oro Valley, Pima County, Arizona. RECORD OF CATEGORICAL EXCLUSION DETERMINATION A. Proposed Action: Western plans to replace deteriorated wood poles, cross arms and X-braces at two existing H-frame structures (11/6 & 1119) located along the Oracle Tucson 115-kV Transmission Line in Pima, Arizona (Figure 1). Built in 1943, its aging components are beyond repair and require replacement. These poles performed poorly during structural tests, and we consider them unstable. This replacement project will ensure the safety of Western's workers and the public as well as reliability of the bulk electric system. Western will accomplish the work by clearing vegetation and blading a level pad at

305

Indoor air pollutants from unvented kerosene heater emissions in mobile homes: studies on particles, semivolatile organics, carbon monoxide, and mutagenicity  

Science Journals Connector (OSTI)

Indoor air pollutants from unvented kerosene heater emissions in mobile homes: studies on particles, semivolatile organics, carbon monoxide, and mutagenicity ...

Judy L. Mumford; Ron W. Williams; Debra B. Walsh; Robert M. Burton; David J. Svendsgaard; Jane C. Chuang; Virginia S. Houk; Joellen Lewtas

1991-10-01T23:59:59.000Z

306

Robert Wood, University of Washington many contributors  

E-Print Network [OSTI]

Robert Wood, University of Washington many contributors VOCALS Education and Outreach Snider (Wyoming) · Dave Spencer (NCSU) · Cindy Twohy (OSU) · Rob Wood/Chris Bretherton/Rhea George

Wood, Robert

307

Reaction Wood: Its Structure and Function  

Science Journals Connector (OSTI)

...WOOD AND OPPOSITE WOOD, TAPPI 52 : 2170 ( 1969 ). LEE...MATERIALS, ARKIV FOR KEMI 12 : 437 ( 1958 ). MOROHOSHI, N...1965). 17. P. Larson, Tappi 52, 2170 (1969). 18...Lindgren, Ark. Kemi 12, 437 (1958); C. L. Lee...

G. Scurfield

1973-02-16T23:59:59.000Z

308

1Wood Borer --WB-XX-W America's Least Wanted Wood-Borers  

E-Print Network [OSTI]

1Wood Borer -- WB-XX-W WB-01-W America's Least Wanted Wood-Borers Department of Entomology OAK. Ferris, Entomologists This metallic wood-boring beetle (Family Bupresti- dae) primarily attacks oaks. Oak wood- borers. Distribution: The native geographical range of this beetle includes parts of Asia, Africa

Ginzel, Matthew

309

STACY L. WOOD Department of Marketing wood@moore.sc.edu  

E-Print Network [OSTI]

STACY L. WOOD Department of Marketing wood@moore.sc.edu Moore School of Business ph. (803) 777) Alba, Joseph, John Lynch, Barton Weitz, Chris Janiszewski, Richard Lutz, Alan Sawyer, Stacy Wood (1997, September-October 1996, p. 12. Wood, Stacy L. (2001), "Remote Purchase Environments: The Influence of Return

Reif, John H.

310

1Wood Borer --WB-XX-W America's Least Wanted Wood-Borers  

E-Print Network [OSTI]

1Wood Borer -- WB-XX-W WB-07-W America's Least Wanted Wood-Borers Department of Entomology JAPANESE. Pupation takes place in the wood and adults emerge by chewing a round exit hole. Adults feed on the tender) #12;2Wood Borer -- WB-07-W October 2012 It is the policy of the Purdue University Cooperative

Ginzel, Matthew

311

1Wood Borer --WB-XX-W America's Least Wanted Wood-Borers  

E-Print Network [OSTI]

1Wood Borer -- WB-XX-W WB-06-W America's Least Wanted Wood-Borers Department of Entomology CAMPHOR August. Female beetles make a horizontal tunnel in the wood initiating gallery construction where/APHIS grant number 10-8100-1488-CA. #12;2Wood Borer -- WB-06-W October 2012 It is the policy of the Purdue

Ginzel, Matthew

312

1Wood Borer --WB-XX-W America's Least Wanted Wood-Borers  

E-Print Network [OSTI]

1Wood Borer -- WB-XX-W WB-08-W America's Least Wanted Wood-Borers Department of Entomology OAK, these beetles feed on oak (Quercus spp). Direct damage results from galleries in the wood that are formed in the breeding season. The host trees for these beetles are important for the wood indus- try, orna

Ginzel, Matthew

313

1Wood Borer --WB-XX-W America's Least Wanted Wood-Borers  

E-Print Network [OSTI]

1Wood Borer -- WB-XX-W WB-09-W America's Least Wanted Wood-Borers Department of Entomology EUROPEAN trees are very crucial for the wood industry, ornamental industry and many species of wildlife: The beetles construct the egg gal- leries perpendicular to the grain of the wood which can be found under

Ginzel, Matthew

314

Seneca Creek Associates, LLC Wood Resources International, LLC "Illegal" Logging and Global Wood Markets  

E-Print Network [OSTI]

Seneca Creek Associates, LLC Wood Resources International, LLC SUMMARY "Illegal" Logging and Global Wood Markets: The Competitive Impacts on the U.S. Wood Products Industry Prepared for: American Forest Phone: 1-202-463-2713 Fax: 1-202- 463-4703 E-mail: agoetzl@sencreek.com Wood Resources International

315

WoodPolymer Composites Prepared by the In Situ Polymerization of Monomers Within Wood  

E-Print Network [OSTI]

Wood­Polymer Composites Prepared by the In Situ Polymerization of Monomers Within Wood Yong-Feng Li in Wiley Online Library (wileyonlinelibrary.com). ABSTRACT: Wood­polymer composites (WPCs) were prepared from poplar wood (P. ussuriensis Komarov) in a two-step procedure. Maleic anhydride (MAN) was first dis

316

Combination fence and solar heater for swimming pools  

SciTech Connect (OSTI)

A combination fence and solar heater for swimming pools comprises a fence shaped for extending about the periphery of the pool to restrict ingress and egress therefrom. A tubular heat exchanger is formed in at least one section of the fence, includes an exterior surface adapted to absorb solar energy, and communicates with the water in the swimming pool. The number of heat exchanger fence sections can be varied in accordance with the climate in which the pool is located. A pump flows the water in the swimming pool through the heat exchanger fence sections during daylight hours, thereby simultaneously heating the water in the pool, and providing an attractive and protective safety barrier about the swimming pool.

Divine, D.L.

1981-07-28T23:59:59.000Z

317

Estimating Total Energy Consumption and Emissions of China's Commercial and Office Buildings  

E-Print Network [OSTI]

water heating Technologies Electric heater Gas boilerCoal Boiler Small cogen Stove District heating Heat pumpElectric water heater Gas boiler Coal Boiler Small cogen Oil

Fridley, David G.

2008-01-01T23:59:59.000Z

318

Table 3.6 Selected Wood and Wood-Related Products in Fuel Consumption, 2002  

U.S. Energy Information Administration (EIA) Indexed Site

6 Selected Wood and Wood-Related Products in Fuel Consumption, 2002;" 6 Selected Wood and Wood-Related Products in Fuel Consumption, 2002;" " Level: National and Regional Data; " " Row: Selected NAICS Codes; Column: Energy Sources;" " Unit: Trillion Btu." ,,"S e l e c t e d","W o o d","a n d","W o o d -","R e l a t e d","P r o d u c t s" ,,,,,"B i o m a s s" ,,,,,,"Wood Residues" ,,,,,,"and","Wood-Related" " "," ","Pulping Liquor"," "," ","Wood","Byproducts","and","RSE",," " "NAICS"," ","or","Biomass","Agricultural","Harvested Directly","from Mill","Paper-Related","Row"

319

Table N5.2. Selected Wood and Wood-Related Products in Fuel Consumption, 1998  

U.S. Energy Information Administration (EIA) Indexed Site

2. Selected Wood and Wood-Related Products in Fuel Consumption, 1998;" 2. Selected Wood and Wood-Related Products in Fuel Consumption, 1998;" " Level: National and Regional Data; " " Row: Selected NAICS Codes; Column: Energy Sources;" " Unit: Trillion Btu." ,,"S e l e c t e d","W o o d","a n d","W o o d -","R e l a t e d","P r o d u c t s" ,,,,,"B i o m a s s" ,,,,,,"Wood Residues" ,,,,,,"and","Wood-Related" " "," ","Pulping Liquor"," "," ","Wood","Byproducts","and","RSE",," " "NAICS"," ","or","Biomass","Agricultural","Harvested Directly","from Mill","Paper-Related","Row"

320

The Reality and Future Scenarios of Commercial Building Energy Consumption in China  

E-Print Network [OSTI]

Geothermal Heat Pump Room AC Heat Pump Stove Electric Heater Small Cogen Gas Boiler Boiler District Heating

Zhou, Nan

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Wood Laminated Composite Louisiana Forest Product Lab  

E-Print Network [OSTI]

Wood Laminated Composite Poles Cheng Piao Louisiana Forest Product Lab School of Renewable Natural, in accordance with CSA O15, ANSI 05 and many other international standards #12;Wood Laminated Composite Poles y, v z, w R r x, u #12;Why Wood Composite Poles · Sufficient strength · More cost-effective · Light

322

c Copyright 2014 Benjamin P. Wood  

E-Print Network [OSTI]

c Copyright 2014 Benjamin P. Wood #12;#12;Software and Hardware Support for Data-Race Exceptions Benjamin P. Wood A dissertation submitted in partial fulfillment of the requirements for the degree;#12;University of Washington Abstract Software and Hardware Support for Data-Race Exceptions Benjamin P. Wood Co

Anderson, Richard

323

Generating Textures of New Zealand Native Wood  

E-Print Network [OSTI]

1 Generating Textures of New Zealand Native Wood Jack Wang Abstract - This report explores algorithms for computer generated textures simulating New Zealand native wood, we out line procedural and Ray tracing. The main goal of this research is to study New Zealand native wood in depth and to gather

Goodman, James R.

324

Harvested Wood Products -an Incentive for Deforestation?  

E-Print Network [OSTI]

1 Harvested Wood Products - an Incentive for Deforestation? Andreas Fischlin1 Abstract Mitigation to help promoting the utilization of the climate-friendly, renewable natural resource wood. This would: Fischlin, A., 2008. Harvested wood products - an incentive for deforestation? In: Hetsch, S. (ed

Fischlin, Andreas

325

CORRUPTION AND ILLEGAL LOGGING IN THE WOOD  

E-Print Network [OSTI]

CORRUPTION AND ILLEGAL LOGGING IN THE WOOD PRODUCTS MARKET: the Italian experience in controlling% of wood international trade is based on illegal logging; a total value of 150 Billion $/year (OECD Environmental Outlook, 2001) · At least 50% of wood removals in the Amazon basin, Central Africa and South

Pettenella, Davide

326

FAO Forestry Department Wood Energy WISDOM Slovenia  

E-Print Network [OSTI]

FAO ­ Forestry Department ­ Wood Energy WISDOM ­ Slovenia Spatial woodfuel production Rudi Drigo Forestry Specialist - Wood energy planning and forest resources monitoring Zivan Veseli and information on wood energy aspects and actively collaborating with member countries in the development

327

Wood Futures Conference 8 November 2007, London  

E-Print Network [OSTI]

Wood Futures Conference 8 November 2007, London Today's and tomorrow's timber resources: Can we #12;Wood Futures Conference 8 November 2007, London Subjects I. Forest resources II. Forest products markets III. Certified forest products IV. Wood energy V. Conclusions VI. Recommendations VII. Questions

328

Research Summary The Chopwell Wood Health Project  

E-Print Network [OSTI]

Research Summary The Chopwell Wood Health Project In 2005, the Department of Health published. This work focused on an evaluation of the Chopwell Wood Health Project in northeast England and highlights University. Background The Chopwell Wood Health Project was developed by a partnership consisting

329

Succession of Wood-inhabiting Fungal Communities  

E-Print Network [OSTI]

Succession of Wood-inhabiting Fungal Communities Diversity and Species Interactions During/Repro, Uppsala 2013 #12;Succession of Wood-inhabiting Fungal Communities ­ Diversity and Species Interactions During the Decomposition of Norway Spruce Abstract Dead wood constitutes an important substrate

330

School of Biological Sciences Juvenile wood  

E-Print Network [OSTI]

School of Biological Sciences Juvenile wood What is it and why should we be concerned? #12;School of Biological Sciences What is juvenile wood? A brief recap. There is no universally accepted definition of juvenile wood. It is typically described as follows · zone near to the pith · displays marked

331

A unified approach to creep of wood  

Science Journals Connector (OSTI)

...research-article A unified approach to creep of wood D. G. Hunt School of Engineering Systems...the most important mechanical property of wood is its resistance to deflection, including...logically, to a new way of characterizing wood creep, namely, plotting data in the form...

1999-01-01T23:59:59.000Z

332

Cultural Values of Trees, Woods  

E-Print Network [OSTI]

research into the importance of the cultural values of trees, woods and forests for sustainable forest managers have to take account of cultural values as one of the central themes of Sustainable Forest and taking them into account as part of the processes of planning and decisionmaking. Cultural values

333

Optical computing Damien Woods a  

E-Print Network [OSTI]

Optical computing Damien Woods a aDepartment of Computer Science and Artificial Intelligence Institute, Vierimaantie 5, 84100 Ylivieska, Finland Abstract We consider optical computers that encode data using images and compute by transforming such images. We give an overview of a number of such optical

Woods, Damien

334

Optical computing Damien Woods a  

E-Print Network [OSTI]

Optical computing Damien Woods a aDepartment of Computer Science and Artificial Intelligence Institute, Vierimaantie 5, 84100 Ylivieska, Finland Abstract In this survey we consider optical computers of such optical computing archi- tectures, including descriptions of the type of hardware commonly used in optical

Woods, Damien

335

Evaluation of a Stirling engine heater bypass with the NASA Lewis nodal-analysis performance code  

SciTech Connect (OSTI)

In support of the US Department of Energy's Stirling Engine Highway Vehicle Systems program, the NASA Lewis Research Center investigated whether bypassing the P-40 Stirling engine heater during regenerative cooling would improve the engine thermal efficiency. The investigation was accomplished by using the Lewis nodal-analysis Stirling engine computer model. Bypassing the P-40 Stirling engine heater at full power resulted in a rise in the indicated thermal efficiency from 40.6 to 41.0 percent. For the idealized (some losses not included) heater bypass that was analyzed, this benefit is not considered significant.

Sullivan, T.J.

1986-05-01T23:59:59.000Z

336

James F. Wood | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

James F. Wood James F. Wood About Us James F. Wood - Deputy Assistant Secretary for Clean Coal Photo of James Wood Photo of James Wood James F. Wood is currently Deputy Assistant Secretary for Clean Coal in the Office of Fossil Energy (FE). In this position, he is responsible for the management and direction of the Office's clean coal research and development programs. Chief among these is the Carbon Sequestration program, the Clean Coal Power Initiative, and FE's $3.4 billion portfolio of Recovery Act projects. Wood has over 30 years of experience in the power industry. Most recently, he was president and CEO of Babcock Power Inc. (BPI), one of the major US-based designer/manufacturers of environmental, pressure part, heat exchanger, combustion equipment and after-market

337

Economics of Residential Gas Furnaces and Water Heaters in United States  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Economics of Residential Gas Furnaces and Water Heaters in United States Economics of Residential Gas Furnaces and Water Heaters in United States New Construction Market Speaker(s): Alex Lekov Gabrielle Wong-Parodi James McMahon Victor Franco Date: May 8, 2009 - 12:00pm Location: 90-3122 In the new single-family home construction market, the choice of what gas furnace and gas water heater combination to install is primarily driven by first cost considerations. In this study, the authors use a life-cycle cost analysis approach that accounts for uncertainty and variability of inputs to assess the economic benefits of installing different gas furnace and water heater combinations. Among other factors, it assesses the economic feasibility of eliminating the traditional metal vents and replacing them with vents made of plastic materials used in condensing and power vent

338

Critical Question #8: When are Heat Pump Water Heaters the Best Solution? |  

Broader source: Energy.gov (indexed) [DOE]

8: When are Heat Pump Water Heaters the Best 8: When are Heat Pump Water Heaters the Best Solution? Critical Question #8: When are Heat Pump Water Heaters the Best Solution? What do we know about actual performance compared to promised performance? What is the best way to manage the space conditioning impacts on a home? Is there an easy decision tree for deciding if this is the best solution for a particular home (Climate? Utility prices? Accessibility? Physical space constraints? Workforce?)? cq8_residential_hpwh_costs_maguire.pdf cq8_hpwh_performance_colon.pdf cq8_hpwhs_multifamily_weitzel.pdf More Documents & Publications Track A - Energy Systems Innovations Illustrative Calculation of Economics for Heat Pump and "Grid-Enabled" Water Heaters Standing Technical Committee Working Sessions

339

A Small Scale Solar Agricultural Dryer with Biomass Burner and Heat Storage Back-Up Heater  

Science Journals Connector (OSTI)

This paper describes a small scale solar agricultural dryer with a simple biomass burner and heat storage back-up heater. The key design features ... are the combination of direct and indirect type solar dryer, t...

Elieser Tarigan; Perapong Tekasakul

2009-01-01T23:59:59.000Z

340

Applications of Commercial Heat Pump Water Heaters in Hot, Humid Climates  

E-Print Network [OSTI]

Heat pump water heaters can provide high-efficiency water heating and supplemental space cooling and dehumidification in commercial buildings throughout the United States. They are particularly attractive in hot, humid areas where cooling loads...

Johnson, K. F.; Shedd, A. C.

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Development and Application of Engineering-Scale Solar Water Heater System Assisted by Heat Pump  

Science Journals Connector (OSTI)

An engineering-scale solar water heater system assisted by heat pump was developed based on ... . The subunits of modularized system include vacuum solar energy collectors, air source heat pump, ... Energy source...

Xiufeng Gao; Shiyu Feng; Wei Hu

2009-01-01T23:59:59.000Z

342

Thermal performance evaluation of a solar air heater with and without thermal energy storage  

Science Journals Connector (OSTI)

This communication presents the experimental study and performance analysis of a solar air heater with and without phase change ... found that the output temperature in case with thermal energy storage (TES) is h...

V. V. Tyagi; A. K. Pandey; S. C. Kaushik

2012-03-01T23:59:59.000Z

343

Design, modeling, and performance of four breadbox passive solar water heaters  

SciTech Connect (OSTI)

As part of the Southwest Border Regional Commission demonstration program on Solar Upgrading of Low-Income Housing, three different types of passive breadbox solar water heaters were designed. Using these designs, a total of six solar water heaters have been installed on public housing units in Las Cruces; these systems act as preheaters to the existing conventional gas-fired water heaters. Under a separate contract from the National Center for Appropriate Technology, four of these installations have been instrumented with two Btu meters each to measure the thermal output of both the solar preheater and conventional backup system. This has enabled measurement of the actual solar fraction of the four instrumented solar systems. The design and construction of the water heaters is described, and the actual performance of the systems is compared with the predicted performance.

Roberts, D. (Energy Management Services, Inc., Santa Fe, NM); Farrer, R.

1981-01-01T23:59:59.000Z

344

ENERGY STAR Residential Water Heaters to Save Americans Up to $823 Million  

Broader source: Energy.gov (indexed) [DOE]

STAR Residential Water Heaters to Save Americans Up to $823 STAR Residential Water Heaters to Save Americans Up to $823 Million in the Next Five Years ENERGY STAR Residential Water Heaters to Save Americans Up to $823 Million in the Next Five Years December 31, 2008 - 9:18am Addthis WASHINGTON - The U.S. Department of Energy (DOE) today announced the availability of ENERGY STAR® residential water heaters. With today's announcement, the ENERGY STAR® program now addresses every major residential appliance found in most American homes. Introduction of this product provides significant potential savings to consumers. Water heating represents up to 15.5 percent of national residential energy consumption, the second largest end use of energy in homes, following heating and cooling. Using one of five specified water heating technologies, ENERGY

345

Buildings Energy Data Book: 5.4 Water Heaters  

Buildings Energy Data Book [EERE]

5 5 Water Heater Efficiencies 2005 2010 Efficiency Stock Minimum Best-Available Residential Type Parameter (1) Efficiency New Efficiency New Efficiency Electric Storage EF 0.90 0.90 (2) 0.95 (2) Electric Instantaneous EF 0.82 0.82 0.98 Electric Heat Pump EF 2.00 2.00 2.35 Gas-Fired Storage EF 0.60 0.59 (3) 0.85 (3) Gas-Fired Instantaneous EF 0.82 0.82 0.98 Oil-Fired Storage EF 0.50 0.53 (4) 0.68 (4) Solar SEF 2.50 N.A. 2.50 2007 2010 Efficiency Stock Minimum Best-Available Commercial Type Parameter (1) Efficiency New Efficiency New Efficiency Electric Storage Thermal Efficiency 0.98 0.98 (5) 0.98 (5) Electric Instantaneous Thermal Efficiency 0.98 0.98 0.98 Gas-Fired Storage Thermal Efficiency 0.78 0.80 (6) 0.96 (6) Gas-Fired Instantaneous Thermal Efficiency 0.77 0.80 0.85 Oil-Fired Storage Thermal Efficiency 0.79 0.78 (7) 0.85 (7) Note(s):

346

Heat pump water heater and storage tank assembly  

DOE Patents [OSTI]

A water heater and storage tank assembly comprises a housing defining a chamber, an inlet for admitting cold water to the chamber, and an outlet for permitting flow of hot water from the chamber. A compressor is mounted on the housing and is removed from the chamber. A condenser comprises a tube adapted to receive refrigerant from the compressor, and winding around the chamber to impart heat to water in the chamber. An evaporator is mounted on the housing and removed from the chamber, the evaporator being adapted to receive refrigerant from the condenser and to discharge refrigerant to conduits in communication with the compressor. An electric resistance element extends into the chamber, and a thermostat is disposed in the chamber and is operative to sense water temperature and to actuate the resistance element upon the water temperature dropping to a selected level. The assembly includes a first connection at an external end of the inlet, a second connection at an external end of the outlet, and a third connection for connecting the resistance element, compressor and evaporator to an electrical power source.

Dieckmann, John T. (Belmont, MA); Nowicki, Brian J. (Watertown, MA); Teagan, W. Peter (Acton, MA); Zogg, Robert (Belmont, MA)

1999-09-07T23:59:59.000Z

347

Preparation of Wood Plastic Composite Sheets by Lateral Extrusion of Solid Woods Using their Fluidity  

Science Journals Connector (OSTI)

Abstract During the course of our studies, we have learned that solid wood has significant deformability characteristics under specific conditions, resulting from slippage occurring among wood cells when wood treated with small-molecular resins is compressed under heat. Furthermore, the deformed shapes obtained are maintained when the resin introduced into the wood cells is cured. In this study, the lateral extrusion of thin discs of wood treated with thermosetting phenol resin is performed to apply this flowlike deformation behavior of wood to wood-forming techniques. Resin-treated thin discs of wood placed in a heating container were compressed by a punch, and under constant pressure the wood flowed into the cavity of a mold. Successful molding conditions were achieved by varying the pressure, temperature and wood fiber direction for the extrusion ratio of 42. The mechanical properties of the wood plastic composite (WPC) sheets obtained by this extrusion process are affected by the fiber direction of the wood in the extrudate, which is almost equivalent to the longitudinal direction of the cellulose crystals of wood. The maximum bending strength of the WPC sheets obtained was about 180MPa, which is suitable for engineering plastics.

Tsunehisa Miki; Masako Seki; Soichi Tanaka; Nobuo Sobue; Ichinori Shigematsu; Kozo Kanayama

2014-01-01T23:59:59.000Z

348

Economics of residential gas furnaces and water heaters in United States new construction market  

SciTech Connect (OSTI)

New single-family home construction represents a significant and important market for the introduction of energy-efficient gas-fired space heating and water-heating equipment. In the new construction market, the choice of furnace and water-heater type is primarily driven by first cost considerations and the availability of power vent and condensing water heaters. Few analysis have been performed to assess the economic impacts of the different combinations of space and water-heating equipment. Thus, equipment is often installed without taking into consideration the potential economic and energy savings of installing space and water-heating equipment combinations. In this study, we use a life-cycle cost analysis that accounts for uncertainty and variability of the analysis inputs to assess the economic benefits of gas furnace and water-heater design combinations. This study accounts not only for the equipment cost but also for the cost of installing, maintaining, repairing, and operating the equipment over its lifetime. Overall, this study, which is focused on US single-family new construction households that install gas furnaces and storage water heaters, finds that installing a condensing or power-vent water heater together with condensing furnace is the most cost-effective option for the majority of these houses. Furthermore, the findings suggest that the new construction residential market could be a target market for the large-scale introduction of a combination of condensing or power-vent water heaters with condensing furnaces.

Lekov, Alex B.; Franco, Victor H.; Wong-Parodi, Gabrielle; McMahon, James E.; Chan, Peter

2009-05-06T23:59:59.000Z

349

California Wood Energy Program1 Gary Brittner2  

E-Print Network [OSTI]

California Wood Energy Program1 Gary Brittner2 The California Department of Forestry Wood Energy projects to increase utilization of wood for energy. The Wood Energy Program came about partly the management of the wood resource. The Department of Forestry recognized that an extensive resource

Standiford, Richard B.

350

Commercial Combustion and CHP Systems  

Science Journals Connector (OSTI)

Wood heat for individual homes (i.e., wood stoves and pellet stoves) is widely recognized and understood in the Northeast USA. Commercial-scale wood heat and CHP (combined heat and power), however, ... the region...

Daniel Ciolkosz; Jim Babcock

2013-01-01T23:59:59.000Z

351

The Bending of Wood With Steam.  

E-Print Network [OSTI]

??Based on experimentation with the steam bending of wood to curved shapes, this thesis describes my involvement with three basic aspects of the process. First (more)

Cottey Jr., James H.

2008-01-01T23:59:59.000Z

352

One on One- Douglas K Woods  

Broader source: Energy.gov [DOE]

A September 2014 interview with Douglas K Woods, the President of the Association for Manufacturing Technology, on the state of US manufacturing.

353

Richard F. Wood | ornl.gov  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

F. Wood (1983) March 05, 2014 Solid State Division For theoretical research on the electronic and vibronic structures and optical properties of defects in ionic crystals, and for...

354

Fracture Modeling of Crack Propagation in Wood and Wood Composites Including Crack Tip Processes and Fiber Bridging Mechanics  

E-Print Network [OSTI]

1 Fracture Modeling of Crack Propagation in Wood and Wood Composites Including Crack Tip Processes and Fiber Bridging Mechanics J. A. Nairn, N. Matsumoto Wood Science & Engineering, Oregon State University wood and wood composites develop process zones often consisting of fibers bridging the crack surfaces

Nairn, John A.

355

North American wood markets hit by United States housing crash North American wood markets hit by United States housing crash  

E-Print Network [OSTI]

North American wood markets hit by United States housing crash North American wood markets hit by United States housing crash North American wood markets hit by United States housing crash 19 themes were: 1. softwood market developments, and 2. wood energy and wood mobilization. The main

356

CSTB / CTBA Wood Preservation -Cannes 2001 MEASUREMENT OF VOC EMISSIONS FROM CURATIVE TREATED WOOD  

E-Print Network [OSTI]

CSTB / CTBA Wood Preservation - Cannes 2001 1 MEASUREMENT OF VOC EMISSIONS FROM CURATIVE TREATED WOOD : A NEW EMISSION TEST CHAMBER METHOD François MAUPETIT1 , Olivier RAMALHO1 and Christophe YRIEIX2 wood, emission test chamber, VOCs Introduction A poor indoor air quality (IAQ) is now recognized

Paris-Sud XI, Université de

357

1Wood Borer --WB-XX-W America's Least Wanted Wood-Borers  

E-Print Network [OSTI]

1Wood Borer -- WB-XX-W WB-05-W America's Least Wanted Wood-Borers Department of Entomology ASIAN) #12;1-888-EXT-INFO · www.extension.purdue.edu 2Wood Borer -- WB-05-W October 2012 It is the policy

Ginzel, Matthew

358

Novel perspectives in wood certification and forensics: dry wood as a source of DNA  

Science Journals Connector (OSTI)

...2002 research-article Novel perspectives in wood certification and forensics: dry wood as a source of DNA M. Deguilloux 1 2 M. Pemonge...St-Mande, 75012 Paris, France The importance of wood for human societies can hardly be understated...

2002-01-01T23:59:59.000Z

359

Performance of unglazed solar ventilation air pre-heaters for broiler barns  

Science Journals Connector (OSTI)

Solar radiation is an interesting heat source for applications requiring a limited amount of energy, such as pre-heating cold fresh air used in venting livestock barns. The objective of this study was to evaluate the energy recovery efficiency of a solar air pre-heater consisting of an unglazed perforated black corrugated siding where the incoming fresh ventilation air picks up heat from its face and back. Installed on the southeast wall of two broiler barns located 40km east of Montreal, Canada, the performance of solar air pre-heaters was monitored over 2years. Sensors inside the barns monitored the temperature of the ambient air, that pre-heated by the solar collector and that exhausted by one of the three operating fans. An on-site weather station measured ambient air temperature, wind direction and velocity and radiation energy absorbed on a vertical plane parallel to the unglazed solar air pre-heaters. The measured vertical solar radiation value was used to evaluate the heat recovery efficiency of the unglazed solar air pre-heaters. Using data from the Varennes Environment Canada weather station located 30km northwest, the solar sensors were found to measure the absorbed solar radiation with a maximum error of 7%, including differences in exterior air moisture. Unglazed, the efficiency of the solar air pre-heaters reached 65% for wind velocities under 2m/s, but dropped below 25% for wind velocities exceeding 7m/s. Nevertheless, the unglazed solar air pre-heaters were able to reduce the heating load especially in March of both years. Over a period starting in November and ending in March, the solar air heaters recovered an energy value equivalent to an annual return on investment of 4.7%.

Sbastien Cordeau; Suzelle Barrington

2011-01-01T23:59:59.000Z

360

Department of Forest and Wood Science Academic Programmes for 2014  

E-Print Network [OSTI]

Department of Forest and Wood Science Academic Programmes for 2014 Postgraduate Diploma Enquiries: Head of Department Contact details: Department of Forest and Wood Science Stellenbosch University;Department of Forest and Wood Science - 2012 2 Contents: Postgraduate Programmes Postgraduate Diploma

Geldenhuys, Jaco

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Wood-Composites Industry Benefits from ALS Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Wood-Composites Industry Benefits from ALS Research Print paris-wood composites Wood scientist and ALS user Jesse Paris (at left) is getting an intimate, 3-D view of adhesive...

362

MODE II FRACTURE BEHAVIOR OF BONDED VISCOELASTIC THERMAL COMPRESSED WOOD  

E-Print Network [OSTI]

MODE II FRACTURE BEHAVIOR OF BONDED VISCOELASTIC THERMAL COMPRESSED WOOD Andreja Kutnar* Graduate Student Department of Wood Science and Technology Biotechnical Faculty University of Ljubljana 1000 Ljubljana, Slovenia Frederick A. Kamke Professor John A. Nairn Professor Department of Wood Science

Nairn, John A.

363

City of Wood River, Nebraska (Utility Company) | Open Energy...  

Open Energy Info (EERE)

Page Edit with form History Facebook icon Twitter icon City of Wood River, Nebraska (Utility Company) Jump to: navigation, search Name: City of Wood River Place: Nebraska...

364

RICHARDS, MARTIN C., AND CHRISTINE M. HAPPEY-WOOD. The ...  

Science Journals Connector (OSTI)

May 30, 1978 ... eutrophic lake of glacial origin, maximum depth about 30 m, that stratifies during summer (Happey-Wood 1975; Pentecost and Happey-Wood.

2000-01-10T23:59:59.000Z

365

CEICEI--BoisBois European Confederation of Woodworking IndustriesEuropean Confederation of Woodworking Industries ValueValue--added wood productsadded wood products  

E-Print Network [OSTI]

of Woodworking Industries ValueValue--added wood productsadded wood products markets: flooringmarkets: flooring of Woodworking Industries Wood flooring and woodWood flooring and wood--based flooringbased flooring · "Genuine" wood ­ Solid products (parquet, planks, ...) ­ Products with a "genuine" top layer · Multilayer parquet

366

Wood3 Resources | Open Energy Information  

Open Energy Info (EERE)

Wood3 Resources Wood3 Resources Jump to: navigation, search Name Wood3 Resources Place Houston, Texas Zip 77056-2409 Product Wood3 Resources is an energy project development firm run by former Federal Energy Regulatory Commission Chairman Pat Wood. Coordinates 29.76045°, -95.369784° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":29.76045,"lon":-95.369784,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

367

Wood Energy Production Credit | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Wood Energy Production Credit Wood Energy Production Credit Wood Energy Production Credit < Back Eligibility Commercial Industrial Savings Category Bioenergy Maximum Rebate Credit may be claimed for a period of five years Program Info Start Date 12/30/1998 (most recent revision) State Missouri Program Type Corporate Tax Credit Rebate Amount $5 per ton of processed materials Provider Missouri Department of Natural Resources Note: No new credits are being issued, effective July 1, 2013. This entry is for informational purposes only. The Wood Energy Tax Credit, as effective January 1, 1997, allows individuals or businesses processing Missouri forestry industry residues into fuels an income tax credit of $5.00 per ton of processed material (e.g., wood pellets). A multiplier of 4 applies to charcoal, based on the

368

Alaska Wood Biomass Energy Project Final Report  

SciTech Connect (OSTI)

The purpose of the Craig Wood Fired Boiler Project is to use waste wood from local sawmilling operations to provide heat to local public buildings, in an effort to reduce the cost of operating those buildings, and put to productive use a byproduct from the wood milling process that otherwise presents an expense to local mills. The scope of the project included the acquisition of a wood boiler and the delivery systems to feed wood fuel to it, the construction of a building to house the boiler and delivery systems, and connection of the boiler facility to three buildings that will benefit from heat generated by the boiler: the Craig Aquatic Center, the Craig Elementary School, and the Craig Middle School buildings.

Jonathan Bolling

2009-03-02T23:59:59.000Z

369

Extraction of hemicelluloses from fiberized spruce wood  

Science Journals Connector (OSTI)

Abstract A novel mechanical pre-treatment method was used to separate the wood chips into fiber bundles in order to extract high molecular weight wood polymers. The mechanical pre-treatment involved chip compression in a conical plug-screw followed by defibration in a fiberizer. The fiberized wood was treated with hot water at various combinations of time and temperature in order to analyze the extraction yield of hemicelluloses at different conditions. Nearly 6mg/g wood of galactoglucomannan was obtained at 90C/120min which was about three times more than what could be extracted from wood chips. The extracted carbohydrates had molecular weight ranging up to 60kDa. About 10% of each of the extracted material had a molecular weight above 30kDa. The extraction liquor could also be reused for consecutive extractions with successive increase in the extraction yield of hemicelluloses.

Shoaib Azhar; Gunnar Henriksson; Hans Theliander; Mikael E. Lindstrm

2015-01-01T23:59:59.000Z

370

The Influence of Selected Wood Characteristics and Composites Production Parameters on the Sorption Behavior of Wood Materials.  

E-Print Network [OSTI]

??The goal of this research was to investigate the influence of selected wood characteristics and composites production parameters on the sorption behavior of wood materials. (more)

Neimsuwan, Trairat

2007-01-01T23:59:59.000Z

371

The Newest Addition to the ENERGY STAR Lineup: Water Heaters | Department  

Broader source: Energy.gov (indexed) [DOE]

The Newest Addition to the ENERGY STAR Lineup: Water Heaters The Newest Addition to the ENERGY STAR Lineup: Water Heaters The Newest Addition to the ENERGY STAR Lineup: Water Heaters February 17, 2009 - 9:48am Addthis Elizabeth Spencer Communicator, National Renewable Energy Laboratory If you've gone shopping for new appliances sometime in the last decade, then you're probably familiar with the ENERGY STAR® label. ENERGY STAR is a partnership between the U.S. Department of Energy and the U.S. Environmental Protection Agency that sets higher-than-average standards for household appliances, electronics, and commercial products. Products that meet these rigorous energy requirements can be designated as ENERGY STAR products. For the average consumer, it basically means that ENERGY STAR products are more energy efficient than their standard counterparts, and therefore will

372

City of San Jose - Solar Hot Water Heaters and Photovoltaic Systems Permit  

Broader source: Energy.gov (indexed) [DOE]

San Jose - Solar Hot Water Heaters and Photovoltaic Systems San Jose - Solar Hot Water Heaters and Photovoltaic Systems Permit Requirements City of San Jose - Solar Hot Water Heaters and Photovoltaic Systems Permit Requirements < Back Eligibility Commercial Construction Industrial Installer/Contractor Multi-Family Residential Residential Savings Category Solar Buying & Making Electricity Program Info State California Program Type Solar/Wind Permitting Standards Provider City of San Jose Building, Planning and Electrical Permits are required for Photovoltiac (PV) systems installed in San Jose. In most cases, PV systems must also undergo a Building Plan Review and an Electrical Plan Review. Building Plan Reviews are not required for installations that meet all of the following criteria: 1. Total panel weight (including frame) is not greater than 5 lbs. per

373

Performance of Heat Pump Water Heaters: Initial Findings of Draw Profile Effect on HPWH Efficiency  

Broader source: Energy.gov (indexed) [DOE]

Performance of Heat Pump Water Heaters Performance of Heat Pump Water Heaters © 2011 Steven Winter Associates, Inc. All rights reserved. © 2011 Steven Winter Associates, Inc. All rights reserved. Evaluation Overview  2000-2002 Evaluated 20 installations with CL&P  Product had problems; not ready for prime time (average COPs of 1.67 was not the problem)  New batch of heaters available, including:  GE's GeoSpring Hybrid (50 gal)  A.O.Smith's Voltex Hybrid (60 & 80 gal)  Stiebel-Eltron's Accelera 300 (80 gal)  Evaluating 14 installations for National Grid, NSTAR, & Cape Light Compact. © 2011 Steven Winter Associates, Inc. All rights reserved. © 2011 Steven Winter Associates, Inc. All rights reserved.

374

Regional Variation in Residential Heat Pump Water Heater Performance in the United States  

Broader source: Energy.gov (indexed) [DOE]

NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. Regional Variation in Residential Heat Pump Water Heater Performance in the US Jeff Maguire 4/30/13 Outline * Why HPWHs? * US Water Heating Market * Overview of HPWHs * Model Description * Results o HPWH Performance o Energy Savings Potential o Breakeven Cost 2 Heat Pump Water Heaters Save $300 a year over standard electric? Save $100 a year over standard gas? Heat Pump Electric Gas 3 Questions about HPWHs * Are HPWHs a good replacement for typical gas and electric storage water heaters? o In different locations across the country? o In conditioned/unconditioned space? o Source energy savings?

375

Development status of coal-fired gas heaters for Brayton-cycle cogeneration systems  

SciTech Connect (OSTI)

Under contract from the Department of Energy, Rocketdyne is developing the technology of coal-fired gas heaters for utilization in Brayton-cycle cogeneration systems. The program encompasses both atmospheric fluidized bed and pulverized coal combustion systems; and it is directed toward the development of gas heater systems capable of delivering high pressure air or helium at 1550 F, when employing metallic heat exchangers, and 1750 F, when employing ceramic heat exchangers. This paper reports on the development status of the program, with discussions of the completed ''screening'' corrosion/erosion tests of candidate heat exchanger materials, a description and summary of the operating experience with the 6- by 6-foot AFB test facility and a projection of the potential for relatively near term commercialization of such heater systems.

Gunn, S.V.; McCarthy, J.R.

1983-01-01T23:59:59.000Z

376

Refractory oxides for high?temperature coal?fired MHD air heaters  

Science Journals Connector (OSTI)

In a coal?burning MHD (Magnetohydrodynamic) power plant the use of a regenerative air heater is one option for producing the required high plasma temperatures. However thermal mechanical and chemical stresses which the MHD environment places on materials are enormous and candidate materials must be carefully tested. We report on the results of such testing for a variety of materials studied in heater test facilities at both FluiDyne Engineering Corporation and at Montana State University. We describe the experimental program and test facilities for MHD heater development the rationale for the choice of materials and their performance (success or failure) under various envirnoments (slagging and nonslagging). Future materials needs are discussed in light of the observed effects.

Richard J. Pollina; Ronald R. Smyth

1981-01-01T23:59:59.000Z

377

Development of Industrially Produced Composite Quench Heaters for the LHC Superconducting Lattice Magnets  

E-Print Network [OSTI]

The quench heaters are vital elements for the protection of the LHC superconducting lattice magnets in the case of resistive transitions of the conductor. The basic concept of magnet protection and technical solutions are briefly presented. The quench heater consists of partially copper clad stainless steel strips sandwiched in between electric insulating carrier foils with electrical and mechanical properties such as to withstand high voltages, low temperatures, pressures and ionizing radiation. Testing of some commercial available electric insulation foils, polyimide (PI), polyetheretherketon (PEEK) and polyarylate (PA) and combinations of adhesive systems which are suitable for industrial processing are described. Possible industrial methods for series production for some 80km of these composite quench heaters are indicated.

Szeless, Balzs; Calvone, F

1996-01-01T23:59:59.000Z

378

Conservation Division regiulations for appliance-efficiency standards relating to refrigerators and freezers, room air conditioners, central air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances  

SciTech Connect (OSTI)

The text of the appliance efficiency standards for certain types of new appliances sold in California is presented. Specifications and test methods to identify complying refrigerators, freezers, air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances are covered.

Not Available

1981-12-16T23:59:59.000Z

379

City-level energy and CO2 reduction effect by introducing new residential water heaters  

Science Journals Connector (OSTI)

Simulation models for a variety of new water heater systems were developed and the models were integrated into a city-level residential energy end-use model for Osaka City. Using the model, the potential of energy conservation and CO2 emission-reduction by introducing new residential water heaters was evaluated at the city-level. Optimal water-heating systems for each household category for primary energy reduction, CO2 emission-reduction, or cost reduction were identified by applying the end-use demand model. The effect of subsidies for installing more efficient systems and the influence of diffusion of these systems on electricity load curves were also discussed.

Yoshiyuki Shimoda; Tomo Okamura; Yohei Yamaguchi; Yukio Yamaguchi; Ayako Taniguchi; Takao Morikawa

2010-01-01T23:59:59.000Z

380

Solvolytic liquefaction of wood under mild conditions  

SciTech Connect (OSTI)

Conversion of wood to liquid products requires cleavage of bonds which crosslink the wood structure. This study examines a low-severity wood solubilization process utilizing a solvent medium consisting of a small amount of sulfuric acid and a potentially wood-derivable alcohol. In one half hour of reaction time at 250/sup 0/C under 15 psia starting nitrogen pressure, over 95% of the wood (maf) was rendered acetone-soluble. The product is a soft, black, bitumen-like solid at room temperature but readily softens at 140/sup 0/C. Between 25 and 50% of the original wood oxygen, depending on alcohol used, was removed as water. Approximately 2 to 17% of the alcohols were retained in the product. Gel permeation chromatography showed that the product's median molecular weight is around 300. Based on experimental and literature results, a mechanism for wood solubilization is proposed. This involves protonation of the etheric oxygen atoms, leading to subsequent bond scission to form carbonium ions which are stabilized by solvent alkoxylation. At severe conditions, polymerization and condensation reactions result in acetone-insoluble materials.

Yu, S.M.

1982-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Heat treated woodnylon 6 composites  

Science Journals Connector (OSTI)

Abstract Heat treatment is a relatively benign modification method that is growing as an industrial process to improve hygroscopicity, dimensional stability and biological resistance of lignocellulosic fillers. There also has been increased interest in the use of lignocellulosic fillers in numerous automotive applications. This study investigated the influence of untreated and heat treated wood fillers on the mechanical and rheological properties of wood filled nylon 6 composites for possible under-the-hood applications in the automobile industry where conditions are too severe for commodity plastics to withstand. In this study, exposure of wood to high temperatures (212C for 8h) improved the thermal stability and crystallinity of wood. Heat treated pine and maple filled nylon 6 composites (at 20wt.% loading) had higher tensile strengths among all formulations and increased tensile strength by 109% and 106% compared to neat nylon 6, respectively. Flexural modulus of elasticity (FMOE) of the neat nylon 6 was 2.34GPa. The FMOE increased by 101% and 82% with the addition of 30wt.% heat treated pine and 20wt.% heat treated maple, where it reached maximum values of 4.71GPa and 4.27GPa, respectively. The rheological properties of the composites correlated with the crystallinity of wood fillers after the heat treatment. Wood fillers with high crystallinity after heat treatment contributed to a higher storage modulus, complex viscosity and steady shear viscosity and low loss factor in the composites. This result suggests that heat treatment substantially affects the mechanical and rheological properties of wood filled nylon 6 composites. The mechanical properties and thermogravimetric analysis indicated that the heat treated wood did not show significant thermal degradation under 250C, suggesting that the wood-filled nylon composites could be especially relevant in thermally challenging areas such as the manufacture of under-the-hood automobile components.

Deniz Aydemir; Alper Kiziltas; Esra Erbas Kiziltas; Douglas J. Gardner; Gokhan Gunduz

2015-01-01T23:59:59.000Z

382

ORIGINAL PAPER M. Grosell C.M. Wood  

E-Print Network [OSTI]

ORIGINAL PAPER M. Grosell á C.M. Wood Branchial versus intestinal silver toxicity and uptake Hogstrand and Wood 1998; Wood et al. 1999 for reviews), much less is known about the exact toxic mechanisms primarily through the apical Na+ channel (Bury and Wood 1999) and targets the basolateral Na/K-AT- Pase

Grosell, Martin

383

1Wood Borer --WB-XX-W Department of Entomology  

E-Print Network [OSTI]

1Wood Borer -- WB-XX-W WB-02-W Department of Entomology America's Least Wanted Wood-Borers CHINESE under the bark and in dry dead wood and complete their development in two or more years. Adults emerge campestris (Faldermann) (Coleoptera: Cerambycidae), an Asian wood-boring beetle recorded in North America

Ginzel, Matthew

384

ALASKAN WOOD FROGS STOCK UP ON SOLUTES TO SURVIVE  

E-Print Network [OSTI]

Inside JEB i ALASKAN WOOD FROGS STOCK UP ON SOLUTES TO SURVIVE Outwardly, the tiny wood frog, Rana these wood frogs, which are native to Alaska, Canada and the northern USA, to unravel their secrets. Costanzo tolerance in a northern population of the wood frog. J. Exp. Biol. 216, 3461-3473. Nicola Stead THE GENETICS

Besansky, Nora J.

385

Original article A study on growth stresses, tension wood  

E-Print Network [OSTI]

Original article A study on growth stresses, tension wood distribution and other related wood variations of wood structure (specific gravity and pulp yield), and the transverse mechanical resistance of wood. To investigate growth stresses, longitudinal displacements after stress release were estimated

Paris-Sud XI, Université de

386

Codes of constant Lee or Euclidean weight Jay A. Wood  

E-Print Network [OSTI]

Codes of constant Lee or Euclidean weight Jay A. Wood Department of Mathematics, Computer Science & Statistics Purdue University Calumet Hammond, Indiana 46323--2094 USA wood@calumet.purdue.edu http://www.calumet.purdue.edu/public/math/wood Scholarly Research Awards. #12; JAY A. WOOD 1. Linear codes as modules Throughout this extended abstract

Wood, Jay

387

1Wood Borer --WB-XX-W Department of Entomology  

E-Print Network [OSTI]

1Wood Borer -- WB-XX-W WB-04-W Department of Entomology America's Least Wanted Wood-Borers BLACK living trees. The wood- boring larvae cause structural damage that may make the trees susceptible). (Photo credit: Stanislaw Kinelski, Bugwood.org) #12;1-888-EXT-INFO · www.extension.purdue.edu 2Wood Borer

Ginzel, Matthew

388

Wood Products Marketing And Value-Added Opportunities  

E-Print Network [OSTI]

Wood Products Marketing And Value-Added Opportunities In Latin America: A Focus on Brazil Richard Vlosky, Ph.D. Professor-Forest Products Marketing Interim Director-Louisiana Forest Products Laboratory Industry Strategic Services & Publisher: WOOD Markets Monthly newsletter WOOD Markets 2002 - The Solid Wood

389

Disposal of CCA-treated Wood: An Evaluation of  

E-Print Network [OSTI]

Disposal of CCA-treated Wood: An Evaluation of Existing and Alternative Management Options (FINAL CHARACTERISTICS OF CCA-TREATED WOOD ASH II.1 Sample Preparation 10 II.2 Laboratory Methods 15 II.3 Laboratory Results 24 CHAPTER III, SORTING TECHNOLOGIES FOR SEPARATING TREATED WOOD FROM UNTREATED WOOD III.1

Florida, University of

390

(1) Biology Department, Woods Hole Oceanographic Institution, Woods Hole, MA 02543 USA(1) Biology Department, Woods Hole Oceanographic Institution, Woods Hole, MA 02543 USA (2) Harvard Medical School, Boston, MA 02114 USA(2) Harvard Medical School, Boston  

E-Print Network [OSTI]

(1) Biology Department, Woods Hole Oceanographic Institution, Woods Hole, MA 02543 USA(1) Biology Department, Woods Hole Oceanographic Institution, Woods Hole, MA 02543 USA (2) Harvard Medical School, Boston, MA 02114 USA(2) Harvard Medical School, Boston, MA 02114 USA (3) Section on Auditory Mechanics, NIDCD

391

DETERMINATION OF IN-SITU THERMAL PROPERTIES OF STRIPA GRANITE FROM TEMPERATURE MEASUREMENTS IN THE FULL-SCALE HEATER EXPERIMENTS: METHOD AND PRELIMINARY RESULTS  

E-Print Network [OSTI]

observed temperatures for the Lulea University pilot heaterPower room '--_I, I\\'~ \\,1 Lulea drift I I I I I I I I Ithe temperature data from the LUlea University pilot heater

Jeffry, J.A.

2010-01-01T23:59:59.000Z

392

Wood and Fiber Science, 36(1), 2004, pp. 107118 2004 by the Society of Wood Science and Technology  

E-Print Network [OSTI]

Wood and Fiber Science, 36(1), 2004, pp. 107­118 2004 by the Society of Wood Science and Technology FORMOSAN SUBTERRANEAN TERMITE RESISTANCE OF BORATE-MODIFIED STRANDBOARD MANUFACTURED FROM SOUTHERN WOOD, but not on termite mortality. Wood species showed no significant effect on the termite resistance. Correlations

393

Wood and Fiber Science, 36(1), 2004, pp. 1725 2004 by the Society of Wood Science and Technology  

E-Print Network [OSTI]

Wood and Fiber Science, 36(1), 2004, pp. 17­25 2004 by the Society of Wood Science and Technology FUNDAMENTALS OF VERTICAL DENSITY PROFILE FORMATION IN WOOD COMPOSITES. PART III. MDF DENSITY FORMATION DURING of Wood Science and Forest Products 210 Cheatham Hall, Virginia Tech Blacksburg, VA 24061-0323 and Timothy

Wang, Siqun

394

Wood and Fiber Science, 35(4), 2003, pp. 482498 2003 by the Society of Wood Science and Technology  

E-Print Network [OSTI]

Wood and Fiber Science, 35(4), 2003, pp. 482­498 2003 by the Society of Wood Science and Technology. INTRODUCTION Strength properties of wood-based compos- ites are related to mean panel density and the density of the average panel density (Kruse et al. 2000). Modeling for the spatial structure of wood composites

395

Wood and Fiber Science, 37(2), 2005, pp. 207212 2005 by the Society of Wood Science and Technology  

E-Print Network [OSTI]

Wood and Fiber Science, 37(2), 2005, pp. 207­212 © 2005 by the Society of Wood Science. Leichti Associate Professor and Barbara L. Gartner Professor Department of Wood Science and Engineering purposes that characterize smaller sections of wood. Moreover, theASTM standards spec- ify loading

Lachenbruch, Barbara

396

Wood and Fiber Science, 37(2), 2005, pp. 304313 2005 by the Society of Wood Science and Technology  

E-Print Network [OSTI]

Wood and Fiber Science, 37(2), 2005, pp. 304­313 © 2005 by the Society of Wood Science and Technology EFFECTS OF PRUNING ON WOOD DENSITY AND TRACHEID LENGTH IN YOUNG DOUGLAS-FIR Barbara L. Gartner Professor Dept. of Wood Science and Engineering Oregon State University Corvallis, OR 97331 James M. Robbins

Lachenbruch, Barbara

397

Wood and Fiber Science, 35(3), 2003, pp. 381396 2003 by the Society of Wood Science and Technology  

E-Print Network [OSTI]

Wood and Fiber Science, 35(3), 2003, pp. 381­396 2003 by the Society of Wood Science and Technology a feasible application of both methods in wood composite research and in a real-time quality control system wood composites widely 1 This paper (NO: 02-40-0457) is published with the approval of the Director

398

Wood and Fiber Science, 36(1), 2004, pp. 7183 2004 by the Society of Wood Science and Technology  

E-Print Network [OSTI]

Wood and Fiber Science, 36(1), 2004, pp. 71­83 2004 by the Society of Wood Science and Technology (Lenth and Kamke 1996). Interest in predicting the consolidation be- havior of wood strand mats has led that strand geometry affects the relative void volume in a mat. #12;72 WOOD AND FIBER SCIENCE, JANUARY 2004, V

399

Wood and Fiber Science, 37(1), 2005, pp. 95111 2004 by the Society of Wood Science and Technology  

E-Print Network [OSTI]

Wood and Fiber Science, 37(1), 2005, pp. 95­111 © 2004 by the Society of Wood Science and Technology SURFACE AND INTERFACIAL CHARACTERIZATION OF WOOD-PVC COMPOSITE: IMAGING MORPHOLOGY AND WETTING wetting behavior of wood-PVC composites in this study. Two-dimensional and time-dependent profiles

400

Analysis of Composite Structure and Primordial Wood Remains in Petrified Wood  

Science Journals Connector (OSTI)

Among all the fossils, petrified wood belongs to the most impressive and most common of materials. Still, its study has not exceeded the purely phenomenological level. The...

Nowak, J; Nowak, D; Chevallier, P; Lekki, J; Van Grieken, R; Kuczumow, A

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

ISSUANCE 2014-12-23: Energy Conservation Program for Consumer Products: Test Procedures for Direct Heating Equipment and Pool Heaters, Final Rule  

Broader source: Energy.gov [DOE]

Energy Conservation Program for Consumer Products: Test Procedures for Direct Heating Equipment and Pool Heaters, Final Rule

402

Arbuthnott Wood Pellets Ltd | Open Energy Information  

Open Energy Info (EERE)

Arbuthnott Wood Pellets Ltd Arbuthnott Wood Pellets Ltd Jump to: navigation, search Name Arbuthnott Wood Pellets Ltd Place Kincardineshire, Scotland, United Kingdom Zip AB30 1PA Product Wood pellet producer. Coordinates 56.932781°, -2.42531° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":56.932781,"lon":-2.42531,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

403

Wood furnance cuts fuel bills and wastes  

SciTech Connect (OSTI)

The use of a wood burning furnace instead of propane to heat the Saddlecraft manufacturing plant in Cherokee, North Carolina, is described. A chart shows gallons of propane usage in winter for five years. (MHR)

Not Available

1982-01-01T23:59:59.000Z

404

Neutron scattering in concrete and wood  

Science Journals Connector (OSTI)

......Article Computational techniques Neutron scattering in concrete and wood A. Facure...library were used to simulate the neutron scattering in barriers of conventional...of the barrier thickness on neutron scattering factors is also being studied......

A. Facure; A. X. Silva; R. C. Falco; V. R. Crispim

2006-09-01T23:59:59.000Z

405

From the Woods to the Refinery  

Broader source: Energy.gov [DOE]

Breakout Session 2DBuilding Market Confidence and Understanding II: Carbon Accounting and Woody Biofuels From the Woods to the Refinery Stephen S. Kelley, Principal and Department Head, Department of Forest Biomaterials, North Carolina State University

406

Conference on "Trees, Woods and Forests in  

E-Print Network [OSTI]

Conference on "Trees, Woods and Forests in British Society" Delegates Pack Organised by the Centre............................................................................................3 1.1 Conference objectives...................................................................................................38 | Forests and Society Conference | BAO and JW | 08/04/2010 2 #12;Forests and Society 1

407

Wood-Burning Heating System Deduction  

Broader source: Energy.gov [DOE]

This statute allows individual taxpayers a deduction for the purchase and installation of a wood-burning heating system. The deduction is equal to the total cost of purchase and installation for...

408

Logs Wood Chips Straw Corn Switchgrass  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Clean energy can come from the sun. The energy in wind can make electricity. Bioenergy comes from plants we can turn into fuel. Logs Wood Chips Straw Corn Switchgrass We can use...

409

Property:Building/SPElectrtyUsePercElctrcEngineHeaters | Open Energy  

Open Energy Info (EERE)

SPElectrtyUsePercElctrcEngineHeaters SPElectrtyUsePercElctrcEngineHeaters Jump to: navigation, search This is a property of type String. Electric engine heaters Pages using the property "Building/SPElectrtyUsePercElctrcEngineHeaters" Showing 25 pages using this property. (previous 25) (next 25) S Sweden Building 05K0001 + 0.0 + Sweden Building 05K0002 + 0.0 + Sweden Building 05K0003 + 0.0 + Sweden Building 05K0004 + 0.0 + Sweden Building 05K0005 + 0.0 + Sweden Building 05K0006 + 3.74913558105 + Sweden Building 05K0007 + 0.0 + Sweden Building 05K0008 + 0.0 + Sweden Building 05K0009 + 0.625045331062 + Sweden Building 05K0010 + 0.0 + Sweden Building 05K0011 + 0.0 + Sweden Building 05K0012 + 2.19814987082 + Sweden Building 05K0013 + 0.0 + Sweden Building 05K0014 + 0.0 + Sweden Building 05K0015 + 0.0 +

410

Property:Building/SPBreakdownOfElctrcityUseKwhM2ElctrcEngineHeaters | Open  

Open Energy Info (EERE)

ElctrcEngineHeaters ElctrcEngineHeaters Jump to: navigation, search This is a property of type String. Electric engine heaters Pages using the property "Building/SPBreakdownOfElctrcityUseKwhM2ElctrcEngineHeaters" Showing 25 pages using this property. (previous 25) (next 25) S Sweden Building 05K0001 + 0.0 + Sweden Building 05K0002 + 0.0 + Sweden Building 05K0003 + 0.0 + Sweden Building 05K0004 + 0.0 + Sweden Building 05K0005 + 0.0 + Sweden Building 05K0006 + 2.44788473329 + Sweden Building 05K0007 + 0.0 + Sweden Building 05K0008 + 0.0 + Sweden Building 05K0009 + 0.353408923575 + Sweden Building 05K0010 + 0.0 + Sweden Building 05K0011 + 0.0 + Sweden Building 05K0012 + 0.835160644485 + Sweden Building 05K0013 + 0.0 + Sweden Building 05K0014 + 0.0 + Sweden Building 05K0015 + 0.0 +

411

An International Survey of Electric Storage Tank Water Heater Efficiency and Standards  

SciTech Connect (OSTI)

Water heating is a main consumer of energy in households, especially in temperate and cold climates. In South Africa, where hot water is typically provided by electric resistance storage tank water heaters (geysers), water heating energy consumption exceeds cooking, refrigeration, and lighting to be the most consumptive single electric appliance in the home. A recent analysis for the Department of Trade and Industry (DTI) performed by the authors estimated that standing losses from electric geysers contributed over 1,000 kWh to the annual electricity bill for South African households that used them. In order to reduce this burden, the South African government is currently pursuing a programme of Energy Efficiency Standards and Labelling (EES&L) for electric appliances, including geysers. In addition, Eskom has a history of promoting heat pump water heaters (HPWH) through incentive programs, which can further reduce energy consumption. This paper provides a survey of international electric storage water heater test procedures and efficiency metrics which can serve as a reference for comparison with proposed geyser standards and ratings in South Africa. Additionally it provides a sample of efficiency technologies employed to improve the efficiency of electric storage water heaters, and outlines programs to promote adoption of improved efficiency. Finally, it surveys current programs used to promote HPWH and considers the potential for this technology to address peak demand more effectively than reduction of standby losses alone

Johnson, Alissa; Lutz, James; McNeil, Michael A.; Covary, Theo

2013-11-13T23:59:59.000Z

412

Enhanced heat transfer tubes for film absorbers of absorption chiller/heater  

SciTech Connect (OSTI)

Absorption chiller/heaters using non-CFC refrigerants are attracting attention as environmentally friendly energy systems. As the refrigerant/absorbent pair, the water/lithium bromide aqueous solution pair is preferably used for most absorption chiller/heaters in Japan. Absorption chiller/heaters, mainly used as water chillers and air-conditioners, are commercially available at least for unit cooling capacities above 60 kW. In absorption chiller/heaters, the absorber must be made compact, because the absorber has the largest heat transfer area of the four primary heat exchangers in the system: the evaporator, absorber, regenerator and condenser. Although a great amount of information is available on the evaporator and condenser, the same type of information concerning the absorber is lacking. This paper introduces two kinds of double fluted tubes called Arm tubs and Floral tubes for film absorbers. Arm tubes are manufactured using a two-pass drawbench process, while Floral tubes are made using a single pass drawbench process. The experiments using a lithium bromide aqueous solution with the addition of 250 ppm n-octyl alcohol as the surfactant showed that Arm tubes and Floral tubes had about 40% higher heat transfer performance than plain tubes. Therefore, Floral tubes are expected to realize a high performance at low cost. Furthermore, the optimization of the number of grooves on the outside of the tubes is also described here.

Sasaki, Naoe; Nosetani, Tadashi [Sumitomo Light Metal Industry, Ltd., Nagoya, Aichi (Japan); Furukawa, Masahiro; Kaneko, Toshiyuki [Sanyo Electric Co., Ltd., Ora, Gunma (Japan). Commercial Air-Conditioning Div.

1995-12-31T23:59:59.000Z

413

An Energy-Efficient Self-Regulating Heater for Flow-Through Applications  

Science Journals Connector (OSTI)

Except for the bifilar wire (two strands separately insulated, as in household two-conductor cable, except in miniature, the fabrication of the other heaters is the same. ... The heated reactor was wrapped in foam sheets for insulation and put inside a 25-mm-thick plastic box. ...

Purnendu K. Dasgupta; Ellis L. Loree; Jianzhong Li; Zhang Genfa

2003-06-12T23:59:59.000Z

414

Efficient generation of extended plasma waveguides with the axicon ignitor-heater scheme  

E-Print Network [OSTI]

. The plasma col- umn was produced by using an axicon to focus a long laser pulse into a line focusEfficient generation of extended plasma waveguides with the axicon ignitor-heater scheme Y.-F. Xiao for generating extended plasma waveguides is developed by using the axicon lens in conjunction with the ignitor

415

Potassium Retention in Updraft Gasification of Wood  

Science Journals Connector (OSTI)

Wood gasifiers are equipment used for a controlled combustion of wood in limited supply of air as the oxidizing medium to generate a combustible product gas. ... Other oxidizing media, such as oxygen and steam, or a combination of any two media can be used in the gasification process. ... The zone where high rates of char combustion and gasification occur is about 15 mm wide above the grate, as determined in a similar-sized gasifier by Di Blasi. ...

Joseph Olwa; Marcus hman; Pettersson Esbjrn; Dan Bostrm; Mackay Okure; Bjrn Kjellstrm

2013-10-14T23:59:59.000Z

416

Wood Fired Steam Plants in Georgia  

E-Print Network [OSTI]

suppliers. Based upon the designs submitted and subsequent negotiations, the Applied Engineering Company (APCO) in Orangeburg, South Carolina, was chosen to do the job. Applied Engineering has been working on wood gasification systems for several years...-20, 1983 company has a large manufacturing plant in Orange burg and is fully capable of fabricating large pressure vessels and heavy industrial equipment. The overall wood gasification system is shown in Figure 1. The fuel for the gasifier is green...

Bulpitt, W. S.

1983-01-01T23:59:59.000Z

417

NEXT GENERATION COMMERCIAL HEAT PUMPWATER HEATER USING CARBON DIOXIDE USING DIFFERENT IMPROVEMENT APPROACHES  

SciTech Connect (OSTI)

Although heat pump water heaters are today widely accepted in Japan, where energy costs are high and government incentives for their use exist, acceptance of such a product in the U.S. has been slow. This trend is slowly changing with the introduction of heat pump water heaters into the residential market, but remains in the commercial sector. Barriers to heat pump water heater acceptance in the commercial market have historically been performance, reliability and first/operating costs. The use of carbon dioxide (R744) as the refrigerant in such a system can improve performance for relatively small increase in initial cost and make this technology more appealing. What makes R744 an excellent candidate for use in heat pump water heaters is not only the wide range of ambient temperatures within which it can operate, but also the excellent ability to match water to refrigerant temperatures on the high side, resulting in very high exit water temperatures of up to 82?ºC, as required by sanitary codes in the U.S. (Food Code, 2005), in a single pass, temperatures that are much more difficult to reach with other refrigerants. This can be especially attractive in applications where this water is used for the purpose of sanitation. While reliability has also been of concern historically, dramatic improvements have been made over the last several years through research done in the automotive industry and commercialization of R744 technology in residential water heating mainly in Japan. This paper presents the performance results from the development of an R744 commercial heat pump water heater of approximately 35 kW and a comparison to a baseline R134a unit of the same capacity and footprint. In addition, recommendations are made for further improvements of the R744 system which could result in possible energy savings of up to 20 %.

Chad Bowers; Michael Petersen; Stefan Elbel; Pega Hrnjak

2012-04-01T23:59:59.000Z

418

Short rotation Wood Crops Program  

SciTech Connect (OSTI)

This report synthesizes the technical progress of research projects in the Short Rotation Woody Crops Program for the year ending September 30, 1989. The primary goal of this research program, sponsored by the US Department of Energy's Biofuels and Municipal Waste Technology Division, is the development of a viable technology for producing renewable feedstocks for conversion to biofuels. One of the more significant accomplishments was the documentation that short-rotation woody crops total delivered costs could be $40/Mg or less under optimistic but attainable conditions. By taking advantage of federal subsidies such as those offered under the Conservation Reserve Program, wood energy feedstock costs could be lower. Genetic improvement studies are broadening species performance within geographic regions and under less-than-optimum site conditions. Advances in physiological research are identifying key characteristics of species productivity and response to nutrient applications. Recent developments utilizing biotechnology have achieved success in cell and tissue culture, somaclonal variation, and gene-insertion studies. Productivity gains have been realized with advanced cultural studies of spacing, coppice, and mixed-species trials. 8 figs., 20 tabs.

Wright, L.L.; Ehrenshaft, A.R.

1990-08-01T23:59:59.000Z

419

The effects of fuel type and stove design on emissions and efficiency of natural-draft semi-gasifier biomass cookstoves  

Science Journals Connector (OSTI)

Abstract To assess the effects of stove design and fuel type on efficiency and emissions, five configurations of natural-draft, top-lit up-draft (TLUD) semi-gasifier cookstoves were tested with two biomass fuels. An energy balance model was developed using measured temperature data to identify the major sources of efficiency loss. Emissions and efficiency varied substantially with stove design and fuel type, and transient increases in CO emission correlated with refueling. The highest measured thermal efficiency was 42%. The lowest CO and PM emissions were 0.6gMJd?1 and 48gMJd?1. These results fall within Tier 3 for high-power efficiency and emissions and suggest that development of a Tier 4 natural-draft semi-gasifier cookstove is possible. The energy balance illustrates that up to 60% of the energy input as fuel can remain as char once the fuel has gasified. This result suggests that both thermal and overall efficiencies should be calculated when evaluating TLUD cookstoves.

Jessica Tryner; Bryan D. Willson; Anthony J. Marchese

2014-01-01T23:59:59.000Z

420

Eliminating air heater plugging and corrosion caused by SCR/SNCR systems for NOx control on coal-fired boilers  

SciTech Connect (OSTI)

In a typical coal-fired power plant the rotary regenerative air heater is responsible for 5-10% of the boiler's total efficiency. The three biggest threats to air heater performance deterioration are corrosion of the heat exchange surfaces, plugging, and air heater leakage through the seals. The article concentrates on the vastly increased level of corrosion and plugging issues associated with installing selective catalytic reduction (SCR) and selective non-catalytic reduction (SNCR) systems for controlling nitrogen oxide emissions. Some injected ammonia in the SCR process reacts with SO{sub 2} to form ammonium sulphate and bisulphate (ABS) which is deposited on the air heater element surfaces. This can be overcome by applying coatings, using corrosion-resistant steels, reconfiguring the air heaters to a two layer design, improving air heater blowers, improving technologies for removing ammonia 'slip' before it enters the air heater, and using new catalysts that reduce the oxidation of SO{sub 2} to SO{sub 3}. 4 figs.

Guffre, J. [Paragon Airheater Technologies (United States)

2007-10-15T23:59:59.000Z

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

European Panel FederationEuropean Panel Federation viewpoint on wood energy policiesviewpoint on wood energy policies  

E-Print Network [OSTI]

European Panel FederationEuropean Panel Federation viewpoint on wood energy policiesviewpoint on wood energy policies Eva JanssensEva Janssens (Economic Adviser)(Economic Adviser) #12;European Panel FederationEuropean Panel Federation Members in 23 countriesMembers in 23 countries Particleboard 32.1 million

422

20 - The use of wood fibers as reinforcements in composites  

Science Journals Connector (OSTI)

Abstract: The chapter begins by discussing the major characteristics of wood in terms of structure, major chemical constituents and wood fiber production methods, which is followed by the description of major manufacturing processes for wood plastic composites (WPCs). It then reviews the effects of different variables such as the nature of wood flour (particle size, wood species, and wood flour content), fillermatrix adhesion, characteristics of polymer matrix, processing conditions, performance-enhancing additives, and foaming agents on the physical, mechanical, thermal, and durability properties of WPCs. Finally, the chapter discusses future trends in \\{WPCs\\} including new materials, novel manufacturing techniques, and emerging applications.

L.M. Matuana; N.M. Stark

2015-01-01T23:59:59.000Z

423

Heat Pump Water Heater Technology Assessment Based on Laboratory Research and Energy Simulation Models: Preprint  

SciTech Connect (OSTI)

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. Laboratory results demonstrate the efficiency of this technology under most of the conditions tested and show that differences in control schemes and design features impact the performance of the individual units. These results were used to understand current model limitations, and then to bracket the energy savings potential for HPWH technology in various US climate regions. Simulation results show that HPWHs are expected to provide significant energy savings in many climate zones when compared to other types of water heaters (up to 64%, including impact on HVAC systems).

Hudon, K.; Sparn, B.; Christensen, D.; Maguire, J.

2012-02-01T23:59:59.000Z

424

Radiation Tolerant Programmable Power Supply for the LHC Beam Screen Heaters  

E-Print Network [OSTI]

For the next LHC run, it is required to install 200W of heating capacity per LHC beam screen heater to regenerate the beam screen by desorption of gas trapped on its walls. In the LHC, there are 272 beam screen heaters and the associated electronics limit presently the heating capacity to 25W. Those electronics are, for the most part, installed inside the LHC tunnel and exposed to its radiation environment. This paper describes the development of a new programmable power supply card that will be integrated into the existing LHC radiation tolerant electronic infrastructure used by the cryogenic system. Radiation tests were undertaken to qualify a power switch capable of coping with the 230Vrms grid voltage and an analog signal multiplexer; these components are required respectively for satisfying the higher power requirements and for reducing the overall cost by using a single analog to digital converter to sample all the signals.

Casas, J

2014-01-01T23:59:59.000Z

425

MHD air heater technology development. Annual technical progress report, January 1, 1980-December 31, 1980  

SciTech Connect (OSTI)

Progress on the technology development of the directly-fired high temperature air heater (HTAH) for MHD power plants is described in detail. The objective of task 1 is to continue development of ceramic materials technology for the directly-fired HTAH. The objectives of task 2 are to demonstrate the technical feasibility of operating a directly-fired HTAH (including both the heater matrix and valves), to continue obtaining information on life and corrosion resistance of HTAH materials, and to obtain design information for full-scale studies and future design work. The objectives of task 3 are to begin the identification of HTAH control requirements and control system needs, and to continue full-scale study efforts incorporating updated materials and design information in order to identify development needs for the HTAH development program. (WHK)

None

1981-03-01T23:59:59.000Z

426

Wood Fuel LP | Open Energy Information  

Open Energy Info (EERE)

Fuel LP Fuel LP Jump to: navigation, search Logo: Wood Fuel LP Name Wood Fuel LP Address 5900 Haynesworth Lane Place Houston, Texas Zip 77034 Sector Biomass Product Wood by-products consulting and marketing Website http://www.woodfuel.com/ Coordinates 29.6221328°, -95.1872605° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":29.6221328,"lon":-95.1872605,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

427

Wood and Derived Fuels | OpenEI  

Open Energy Info (EERE)

1 1 Varnish cache server Browse Upload data GDR 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142288361 Varnish cache server Wood and Derived Fuels Dataset Summary Description Annual commodity balances (supply, consumption) for renewables and waste in the UK from 1998 to 2009. Published as part of the Digest of UK energy statistics (DUKES), by the UK Department of Energy & Climate Change (DECC). Waste includes: wood waste, farm waste, sewage gas, landfill gas, waste and tyres. Renewables includes: wood, plant-based biomass, geothermal and active solar heat, hydro, wind, wave and tidal, and liquid biofuels. Source UK Department of Energy and Climate Change (DECC) Date Released July 29th, 2010 (4 years ago)

428

Experimental study of a thermosyphon solar water heater coupled to a fibre-reinforced plastic (FRP) storage tank  

Science Journals Connector (OSTI)

The thermal performance of the thermosyphon solar water heater was analyzed to show its ... %. Also, an analysis of the temperature storage characteristics of a novel fibre-reinforced plastic (FRP) storage tank w...

P. N. Nwosu; O. U. Oparaku; W. I. Okonkwo; G. O. Unachukwu

2011-09-01T23:59:59.000Z

429

Thermal calculation of combined transpiration-liquid cooling of discharge-chamber walls of an electric-arc heater  

Science Journals Connector (OSTI)

The article presents a theoretical calculation of the temperature profiles and optimal thicknesses of porous and solid cooled walls, which provide a steady-state operation of an electric-arc heater with transpira...

G. L. Dobroedov; V. I. Krylovich

1970-03-01T23:59:59.000Z

430

Performance Analysis of a Transcritical CO2 Heat Pump Water Heater Incorporating a Brazed-Plate Gas-cooler.  

E-Print Network [OSTI]

??This study focuses on the experimental testing and numerical modeling of a 4.5 kW transcritical CO2 heat pump water heater at Queens University in the (more)

Murray, PORTIA

2015-01-01T23:59:59.000Z

431

Cook stove assembly  

SciTech Connect (OSTI)

A combustion chamber, having an upper part and a lower part, may include an annular constriction, in combination with the combustion chamber, to aid in directing partially combusted gases such as carbon monoxide away from the periphery of the combustion chamber back toward its center, and into the flame front. The annular constriction may also impede the flow of partially combusted gases located at the periphery, thus increasing the time these gases spend within the combustion chamber and increasing the likelihood that any products of incomplete combustion will undergo combustion. The combustion chamber may further comprise a dual burner cooktop for directing combustion gases and exhaust to multiple cooking vessels. In further embodiments, the combustion chamber may be made of, lined, or clad with a metal alloy comprising iron, chromium, and aluminum.

DeFoort, Morgan W; Willson, Bryan D; Lorenz, Nathan; Brady, Michael P; Marchese, Anthony; Miller-Lionberg, Daniel D

2014-12-02T23:59:59.000Z

432

Expert Meeting Report: Recommendations for Applying Water Heaters in Combination Space and Domestic Water Heating Systems  

SciTech Connect (OSTI)

The topic of this meeting was 'Recommendations For Applying Water Heaters In Combination Space And Domestic Water Heating Systems.' Presentations and discussions centered on the design, performance, and maintenance of these combination systems, with the goal of developing foundational information toward the development of a Building America Measure Guideline on this topic. The meeting was held at the Westford Regency Hotel, in Westford, Massachusetts on 7/31/2011.

Rudd, A.; Ueno, K.; Bergey, D.; Osser, R.

2012-07-01T23:59:59.000Z

433

Field Performance of Heat Pump Water Heaters in the Northeast, Massachusetts and Rhode Island (Fact Sheet)  

SciTech Connect (OSTI)

Heat pump water heaters (HPWHs) are finally entering the mainstream residential water heater market. Potential catalysts are increased consumer demand for higher energy efficiency electric water heating and a new Federal water heating standard that effectively mandates use of HPWHs for electric storage water heaters with nominal capacities greater than 55 gallons. When compared to electric resistance water heating, the energy and cost savings potential of HPWHs is tremendous. Converting all electric resistance water heaters to HPWHs could save American consumers 7.8 billion dollars annually ($182 per household) in water heating operating costs and cut annual residential source energy consumption for water heating by 0.70 quads. Steven Winter Associates, Inc. embarked on one of the first in situ studies of these newly released HPWH products through a partnership with two sponsoring electric utility companies, National Grid and NSTAR, and one sponsoring energy efficiency service program administrator, Cape Light Compact. Recent laboratory studies have measured performance of HPWHs under various operating conditions, but publicly available field studies have not been as available. This evaluation attempts to provide publicly available field data on new HPWHs by monitoring the performance of three recently released products (General Electric GeoSpring, A.O. Smith Voltex, and Stiebel Eltron Accelera 300). Fourteen HPWHs were installed in Massachusetts and Rhode Island and monitored for over a year. Of the 14 units, ten were General Electric models (50 gallon units), two were Stiebel Eltron models (80 gallon units), and two were A.O. Smith models (one 60-gallon and one 80-gallon unit).

Not Available

2013-12-01T23:59:59.000Z

434

Microcantilever heater-thermometer with integrated temperature-compensated strain sensor  

DOE Patents [OSTI]

The present invention provides microcantilever hotplate devices which incorporate temperature compensating strain sensors. The microcantilever hotplate devices of the present invention comprise microcantilevers having temperature compensating strain sensors and resistive heaters. The present invention also provides methods for using a microcantilever hotplate for temperature compensated surface stress measurements, chemical/biochemical sensing, measuring various properties of compounds adhered to the microcantilever hotplate surface, or for temperature compensated deflection measurements.

King, William P. (Champaign, IL); Lee, Jungchul (Champaign, IL); Goericke, Fabian T. (Wolfsburg, DE)

2011-04-19T23:59:59.000Z

435

Wood-Fiber/High-Density-Polyethylene Composites: Compounding Process  

E-Print Network [OSTI]

Wood-Fiber/High-Density-Polyethylene Composites: Compounding Process J. Z. Lu,1 Q. Wu,1 I. I parameters for the wood-fiber/high-density-polyethylene blends at 60 rpm were a temperature of 180°C

436

Drawing a Graph in a Hypercube David R. Wood  

E-Print Network [OSTI]

Drawing a Graph in a Hypercube David R. Wood #3; Departament de Matem#18;atica Aplicada II Universitat Polit#18;ecnica de Catalunya Barcelona, Spain david.wood@upc.edu Submitted: Nov 16, 2004; Accepted

Wood, David R.

437

Ring Involutions and Self-Dual Codes Jay A. Wood  

E-Print Network [OSTI]

Ring Involutions and Self-Dual Codes Jay A. Wood Department of Mathematics Western Michigan University jay.wood@wmich.edu AMS meeting, Lexington, Kentucky March 27, 2010 #12;Acknowledgments Much

Wood, Jay

438

RELATIVE ONE-WEIGHT LINEAR CODES JAY A. WOOD  

E-Print Network [OSTI]

RELATIVE ONE-WEIGHT LINEAR CODES JAY A. WOOD In memory of Professor F. E. P. Hirzebruch, 17 October University. 1 #12;2 JAY A. WOOD G thus defines a linear functional (a "coordinate functional") on the k

Wood, Jay

439

Generalizing Halfspaces 1 Eugene Fink 2 Derick Wood 3  

E-Print Network [OSTI]

Generalizing Halfspaces 1 Eugene Fink 2 Derick Wood 3 Abstract Restricted­orientation convexity, as a generalization of standard convexity [9]. Rawlins, Wood, and Schuierer studied planar O­convex sets

Fink, Eugene

440

Drawing a Graph in a Hypercube David R. Wood  

E-Print Network [OSTI]

Drawing a Graph in a Hypercube David R. Wood Departament de Matem`atica Aplicada II Universitat Polit`ecnica de Catalunya Barcelona, Spain david.wood@upc.edu Submitted: Nov 16, 2004; Accepted: Aug 11

Wood, David R.

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Wood mobilization: la nuova frontiera delle politiche forestali  

E-Print Network [OSTI]

8-03-2013 1 Wood mobilization: la nuova frontiera delle politiche forestali europee CONAF settore forestale, un nuovo tema-guida: Wood Mobilization Task Force Foreste2. Green o grey? 3. Politica

Pettenella, Davide

442

XML Structure Compression Mark Levene and Peter Wood  

E-Print Network [OSTI]

XML Structure Compression Mark Levene and Peter Wood Birkbeck College, University of London London WC1E 7HX, U.K. {m.levene,p.wood}@dcs.bbk.ac.uk Abstract XML is becoming the universal language

Levene, Mark

443

Characters and finite Frobenius rings Jay A. Wood  

E-Print Network [OSTI]

Characters and finite Frobenius rings Jay A. Wood Department of Mathematics Western Michigan-modules; 3. R = R as right R-modules. Due independently to Hirano, 1997, and Wood, 1999. JW (WMU) Frobenius

Wood, Jay

444

A study of the molecular mechanics of wood cell walls  

E-Print Network [OSTI]

Wood is the original structural material, developed by nature to support tall plants. Every advantageous feature of wood as used in artificial structures is rooted in the plant's evolved capability to withstand the conditions ...

Adler, David, S.M. (David C.). Massachusetts Institute of Technology

2013-01-01T23:59:59.000Z

445

Robert W. Wood: The Scientist who Played with Optics  

Science Journals Connector (OSTI)

Robert Williams Wood viewed the natural world as his playground. For him, science was a highly creative endeavor to be approached with curiosity and awe. Wood was also a scientific...

Masters, Barry R

2009-01-01T23:59:59.000Z

446

OpenEI - Wood and Derived Fuels  

Open Energy Info (EERE)

UK Energy Statistics: UK Energy Statistics: Renewables and Waste, Commodity Balances (2010) http://en.openei.org/datasets/node/82 Annual commodity balances (supply, consumption) for renewables and waste in the UK from 1998 to 2009. Published as part of the Digest of UK energy statistics (DUKES), by the UK Department of Energy & Climate Change (DECC). Waste includes: wood waste, farm waste, sewage gas, landfill gas, waste and tyres. Renewables includes: wood, plant-based biomass, geothermal and active solar heat, hydro, wind, wave and tidal, and liquid biofuels.

License
Type of

447

International Trade of Wood Pellets (Brochure)  

SciTech Connect (OSTI)

The production of wood pellets has increased dramatically in recent years due in large part to aggressive emissions policy in the European Union; the main markets that currently supply the European market are North America and Russia. However, current market circumstances and trade dynamics could change depending on the development of emerging markets, foreign exchange rates, and the evolution of carbon policies. This fact sheet outlines the existing and potential participants in the wood pellets market, along with historical data on production, trade, and prices.

Not Available

2013-05-01T23:59:59.000Z

448

A Wood-Fired Gas Turbine Plant  

E-Print Network [OSTI]

-fired turbine, it probably seems that a wood gasification system must be involved. This is a proven and accepted method of producing gas to drive this type of power unit, but the fuel produced is a dirty fuel containing large amounts of me' ~ "'1 re, tars..., and other undesirable impurities that make it unsuitable for use as a fuel until a rather expensive cleanup process and residual waste disposal can take place. However, Aerospace Research felt that there must be a way to improve on the wood gasification...

Powell, S. H.; Hamrick, J. T.

449

Volatile constituents in a wood pyrolysis oil  

E-Print Network [OSTI]

Science VOLATILE CONSTITUTENTS IN A WOOD PYROLYSIS OIL A Thesis SHIH-CHIEN LIN Appro d as to style and content by: (Chairman of Committee) Head of epa tmen (Member Member Nay 1978 442936 ABSTRACT Volatile Constituents in a Wood Pyrolysis Oil.../120 Supelcoport. Other trace constituents of volatile acid were also 'dentifi="' by trap- ping the substances from the C. C. column into i: n;- 0-sh ped capillary tube and subjecting to mass spectrometry. The corrosivity of pyrolysis oil and it, volati'e acids...

Lin, Shih-Chien

1978-01-01T23:59:59.000Z

450

Evaluation of TANK Water Heater Simulation Model as Embedded in HWSim  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

TANK Water Heater Simulation Model as Embedded in HWSim TANK Water Heater Simulation Model as Embedded in HWSim Title Evaluation of TANK Water Heater Simulation Model as Embedded in HWSim Publication Type Report LBNL Report Number LBNL-5092E Year of Publication 2010 Authors Lutz, James D. Document Number LBNL-5092E Pagination 11 Date Published December 22 Publisher Lawrence Berkeley National Laboratory City Berkeley ISBN Number LBNL-5092E Abstract This report evaluates the hot water temperatures and flow rates as calculated by the combined HWSim and TANK simulation models. Notes This work was sponsored by the Gas Technology Institute (GTI) which is funded by the California Energy Commission, Public Interest Energy Research (PIER) Program, under Residential Water Heating Program Contract No. 500-08-060. This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology, State, and Community Programs, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231.

451

Advanced Oxyfuel Boilers and Process Heaters for Cost Effective CO2 Capture and Sequestration  

SciTech Connect (OSTI)

The purpose of the advanced boilers and process heaters program is to assess the feasibility of integrating Oxygen Transport Membranes (OTM) into combustion processes for cost effective CO{sub 2} capture and sequestration. Introducing CO{sub 2} capture into traditional combustion processes can be expensive, and the pursuit of alternative methods, like the advanced boiler/process heater system, may yield a simple and cost effective solution. In order to assess the integration of an advanced boiler/process heater process, this program addressed the following tasks: Task 1--Conceptual Design; Task 2--Laboratory Scale Evaluation; Task 3--OTM Development; Task 4--Economic Evaluation and Commercialization Planning; and Task 5--Program Management. This Final report documents and summarizes all of the work performed for the DOE award DE-FC26-01NT41147 during the period from January 2002-March 2007. This report outlines accomplishments for the following tasks: conceptual design and economic analysis, oxygen transport membrane (OTM) development, laboratory scale evaluations, and program management.

Max Christie; Rick Victor; Bart van Hassel; Nagendra Nagabushana; Juan Li; Joseph Corpus; Jamie Wilson

2007-03-31T23:59:59.000Z

452

Development and Field Trial of Dimpled-Tube Technology for Chemical Industry Process Heaters  

SciTech Connect (OSTI)

Most approaches to increasing heat transfer rates in the convection sections of gas-fired process heaters involve the incorporation of fins, baffles, turbulizers, etc. to increase either the heat transfer surface area or turbulence or both. Although these approaches are effective in increasing the heat transfer rates, this increase is invariably accompanied by an associated increase in convection section pressure drop as well as, for heaters firing dirty fuel mixtures, increased fouling of the tubes both of which are highly undesirable. GTI has identified an approach that will increase heat transfer rates without a significant increase in pressure drop or fouling rate. Compared to other types of heat transfer enhancement approaches, the proposed dimpled tube approach achieves very high heat transfer rates at the lowest pressure drops. Incorporating this approach into convection sections of chemical industry fired process heaters may increase energy efficiency by 3-5%. The energy efficiency increase will allow reducing firing rates to provide the required heating duty while reducing the emissions of CO2 and NOx.

Yaroslav Chudnovsky; Aleksandr Kozlov

2006-10-12T23:59:59.000Z

453

Deplump for Streaming Data Nicholas Bartlett Frank Wood  

E-Print Network [OSTI]

Deplump for Streaming Data Nicholas Bartlett Frank Wood Department of Statistics, Columbia of discrete sequences called the sequence memoizer [Wood et al., 2009]. Gasthaus et al. showed that although was reposed on a sequence memo- izer [Wood et al., 2009] whose space complexity was linear in the length

Wood, Frank

454

Wood Products Identification by Internal Characteristics Readings C. FUENTEALBA1  

E-Print Network [OSTI]

Wood Products Identification by Internal Characteristics Readings C. FUENTEALBA1 , C. SIMON2 , D.fuentealba@cran.uhp-nancy.fr 5 LERMAB - Wood Research Laboratory, Epinal, France, e-mail: daniel- proving control of production tools and reacting to their defi- ciencies. For wood industries

Boyer, Edmond

455

Wood in rivers: interactions with channel morphology and processes  

E-Print Network [OSTI]

Editorial Wood in rivers: interactions with channel morphology and processes No doubt about it, wood complicates fluvial geo- morphology. It messes up nice tidy streams, compli- cates quantitative through the study of channels lacking a substantial load of wood debris (Leopold et al., 1964

Montgomery, David R.

456

Using Wood Quality Measures to Evaluate Second-Growth Redwood  

E-Print Network [OSTI]

553 Using Wood Quality Measures to Evaluate Second-Growth Redwood Stephen L. Quarles1 and Yana stability, durability, microfibril angle, redwood, wood quality Introduction Redwood has long been a valued" or "resistant or very resistant" (Wood Handbook 1999). 1 University of California Cooperative Extension (Advisor

Standiford, Richard B.

457

Frederic Wood Compiled by Michael W. Pidgeon (1985)  

E-Print Network [OSTI]

Frederic Wood fonds Compiled by Michael W. Pidgeon (1985) University of British Columbia Archives Description Frederic Wood fonds. ­ 1915-1973. 33 cm of textual records. 22 photographs. Biographical Sketch Born in Victoria, B.C., Frederic Gordon Campbell Wood (1887-1976) enrolled in the first class

Handy, Todd C.

458

Surface light fields for 3D photography Daniel N. Wood  

E-Print Network [OSTI]

Surface light fields for 3D photography Daniel N. Wood A dissertation submitted in partial This is to certify that I have examined this copy of a doctoral dissertation by Daniel N. Wood and have found for 3D photography by Daniel N. Wood Chair of Supervisory Committee: Associate Professor Brian L

Washington at Seattle, University of

459

Wood Science and Nanotechnology: Overview and Our Efforts  

E-Print Network [OSTI]

Wood Science and Nanotechnology: Overview and Our Efforts Siqun Wang, Ph.D. Department of Forestry. Bot. 17, 543-588 (1886). Wang UT CRC #12;Wood Structure MICROFIBRIL STRUCTURE CRYSTALLINE REGIONS wood fibers under axial tensile strain Nature 1971; 229:252-3 Page DH, EI-Hosseiny F., Winkler K. Wang

Gray, Matthew

460

Robert Wood Professor of Engineering and Applied Sciences at  

E-Print Network [OSTI]

Robert Wood Professor of Engineering and Applied Sciences at Harvard's School of Engineering and Applied Sciences Mechanical Engineering Robert Wood is the Charles River Professor of Engineering member of the Wyss Institute for Biologically Inspired Engineering. Prof. Wood completed his M.S. and Ph

Lin, Xi

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Wood ants use resin to protect themselves against pathogens  

E-Print Network [OSTI]

Wood ants use resin to protect themselves against pathogens Michel Chapuisat1,*, Anne Oppliger2. Wood ants, Formica paralugubris, commonly bring back pieces of solidified coniferous resin of larvae exposed to the entomopathogenic fungus Metarhizium anisopliae. These results show that wood ants

Lehmann, Laurent

462

Codes of constant Lee or Euclidean weight Jay A. Wood  

E-Print Network [OSTI]

Codes of constant Lee or Euclidean weight Jay A. Wood Department of Mathematics, Computer Science & Statistics Purdue University Calumet Hammond, Indiana 46323 2094 USA wood@calumet.purdue.edu http: www.calumet.purdue.edu public math wood Abstract. Carlet 2 has determined the linear codes over Z=4 of constant Lee weight

Wood, Jay

463

Wood Density and Growth Conifers Introduced to Hawaii  

E-Print Network [OSTI]

Wood Density and Growth of Some Conifers Introduced to Hawaii Roger G. Skolmen U . S . F O R E - Berkeley, California Forest Service - U. S. Department of Agriculture #12;Skolmen, Roger G. 1963. Wood Expt. Sta. 20 pp., illus. (U.S. Forest Serv. Res Paper PSW-12) The specific gravity of the wood of 14

Standiford, Richard B.

464

Relative Leaching and Aquatic Toxicity of Pressure-Treated Wood  

E-Print Network [OSTI]

Relative Leaching and Aquatic Toxicity of Pressure-Treated Wood Products Using Batch Leaching Tests leaching tests. The wood preservatives included chromated copper arsenate (CCA), alkaline copper quaternary, copper boron azole, copper citrate, and copper dimeth- yldithiocarbamate. An unpreserved wood sample

Florida, University of

465

Modelling Traceability in the Forestry Wood Supply Chain  

E-Print Network [OSTI]

Modelling Traceability in the Forestry Wood Supply Chain Antti Sirkka University of Tampere Tieto.sirkka@uta.fi antti.sirkka@tietoenator.com Abstract--Equivalent of 5 billion of wood raw material is going to waste wood production system. The RFID-technology can achieve automatic traceability by enabling us

466

Landfill Disposal of CCA-Treated Wood with Construction and  

E-Print Network [OSTI]

Landfill Disposal of CCA-Treated Wood with Construction and Demolition (C&D) Debris: Arsenic phased out of many residential uses in the United States, the disposal of CCA-treated wood remains. Catastrophic events have also led to the concentrated disposal of CCA-treated wood, often in unlined landfills

Florida, University of

467

Bryan H. Wood Assistant Deputy Commandant of the Marine Corps  

E-Print Network [OSTI]

6-14 Bryan H. Wood Assistant Deputy Commandant of the Marine Corps for Installations & Logistics HEADQUARTERS, U. S. MARINE CORPS Mr. Bryan H. Wood is the Assistant Deputy Commandant of the Marine Corps for Installations & Logistics. Mr. Wood serves as the principal deputy and technical assistant to the Deputy

468

Measuring Interfacial Stiffness of Adhesively-Bonded Wood  

E-Print Network [OSTI]

1 Measuring Interfacial Stiffness of Adhesively-Bonded Wood Edward A. Le FPInnovations - Engineered Wood Products Manufacturing 2665 East Mall Vancouver, BC V6T 1W5 Canada Email: Edward.Le@FPInnovations.ca John A. Nairn Wood Science & Engineering Oregon State University Corvallis, OR 97330, USA Email: John

Nairn, John A.

469

A Chemical Stain for Identifying Arsenic-Treated Wood  

E-Print Network [OSTI]

A Chemical Stain for Identifying Arsenic-Treated Wood (FINAL) Submitted June 23, 2006 Amy Omae-TREATED WOOD II.1 Applying Phosphate Stains to Arsenate Stains 7 II.2 A Potential Arsenic-Test Kit 14 II.3 Whole Wood Application of the Modified Stannous Chloride Stain 19 II.4 Other Attempted Stain

Florida, University of

470

Health effects assessment of exposure to particles from wood  

E-Print Network [OSTI]

Health effects assessment of exposure to particles from wood smoke Elsa Nielsen, Marianne Dybdahl HUMAN EXPOSURE TO PARTICLES FROM WOOD SMOKE 7 HUMAN HEALTH EFFECTS 8 Human non-cancer health effects from exposure to particles from wood smoke 8 Human carcinogenic effects from exposure to particles from

471

The Uses of Wood: Long Term Prospects [and Discussion  

Science Journals Connector (OSTI)

...July 1975 research-article The Uses of Wood: Long Term Prospects [and Discussion...The longer term prospects for the use of wood depend upon the continued availability of suitable material and the ability of wood products to compete in cost and performance...

1975-01-01T23:59:59.000Z

472

Wood September 28, 2002 DEPARTMENT OF MATERIALS SCIENCE  

E-Print Network [OSTI]

Wood September 28, 2002 1 DEPARTMENT OF MATERIALS SCIENCE AND ENGINEERING CARNEGIE MELLON: Microstructure-Sensitive Mechanical Properties #12;Wood September 28, 2002 2 Introduction Reading will also have an opportunity to perform similar experiments on various types of wood. These will illustrate

Rollett, Anthony D.

473

SURFACE CHARACTERIZATION OF CHEMICALLY MODIFIED WOOD: DYNAMIC WETTABILITY1  

E-Print Network [OSTI]

SURFACE CHARACTERIZATION OF CHEMICALLY MODIFIED WOOD: DYNAMIC WETTABILITY1 John Z. Lu* Postdoctoral-3015 [a maleated polypropylene (MAPP) copolymer with a high molecular weight]-treated wood surface the dynamic wettability of wood surfaces modified with different coupling agents. Keywords: Chemical

474

Image-based characterization of cement pore structure using Wood`s metal intrusion  

SciTech Connect (OSTI)

Mercury intrusion porosimetry is a widely used technique for characterization of the pore size distribution of cement-based materials. However, the technique has several limitations, among which are the ink bottle effect and a cylindrical pore geometry assumption that lead to inaccurate pore size distribution curves. By substituting Wood`s metal for mercury as the intruding liquid, scanning electron microscopy and imaging techniques can be applied to the sample after intrusion. The molten Wood`s metal solidifies within the pore structure of the sample, which allows it to be sectioned and observed in the scanning electron microscopy. From here, the sample can be analyzed both qualitatively, by observing the changes in the appearance of the sample as the intrusion process progresses, and quantitatively, by applying image analysis techniques. This study provides insight for better interpretation of mercury intrusion porosimetry results and the possibility for quantitative characterization of the spatial geometry of pores in cement-based materials.

Willis, K.L.; Abell, A.B.; Lange, D.A. [Univ. of Illinois, Urbana, IL (United States). Dept. of Civil Engineering] [Univ. of Illinois, Urbana, IL (United States). Dept. of Civil Engineering

1998-12-01T23:59:59.000Z

475

Substitution of Wood from Plantation Forestry for Wood from Deforestation: Modelling the Effects on Carbon Storage  

Science Journals Connector (OSTI)

Biomass options, for example afforestation, forest protection, use of biofuels as a substitute for fossil fuels, or use of wood instead of other materials, are frequently mentioned as possibilities to mitigate...

Bernhard Schlamadinger; Gregg Marland

1998-01-01T23:59:59.000Z

476

Evolution of CO2 during the fixation of chromium containing wood preservatives on wood  

Science Journals Connector (OSTI)

...A titration procedure was used to confirm carbon dioxide evolution from wood treated with solutions containing chromic acid and...vs soft maple), solution concentration and reaction temperature on the rate and...

J. Porandowski; P. A. Cooper; M. Kaldas; Y. T. Ung

1998-03-01T23:59:59.000Z

477

Balsa Wood Bridge Competition Sponsored by  

E-Print Network [OSTI]

Balsa Wood Bridge Competition Sponsored by: The University of Tennessee, Department of Civil and Environmental Engineering Description: The objective of this event is to design and build the lightest bridge capable of supporting a given load over a given span. The bridge must allow the passage of one Hot Wheel

Tennessee, University of

478

Wood anomalies in resonant photonic quasicrystals  

E-Print Network [OSTI]

A theory of light diffraction from planar quasicrystalline lattice with resonant scatterers is presented. Rich structure, absent in the periodic case, is found in specular reflection spectra, and interpreted as a specific kind of Wood anomalies, characteristic for quasicrystals. The theory is applied to semiconductor quantum dots arranged in Penrose tiling.

Poddubny, A N

2010-01-01T23:59:59.000Z

479

Milnor-Wood inequalities for products  

E-Print Network [OSTI]

We prove Milnor-Wood inequalities for local products of manifolds. As a consequence, we establish the generalized Chern Conjecture for products $M\\times \\Sigma^k$ for any product of a manifold $M$ with a product of $k$ copies of a surface $\\Sigma$ for $k$ sufficiently large.

Bucher, Michelle

2012-01-01T23:59:59.000Z

480

Energie-Cits 2001 BIOMASS -WOOD  

E-Print Network [OSTI]

Energie-Cités 2001 BIOMASS - WOOD Gasification / Cogeneration ARMAGH United Kingdom Gasification is transferring the combustible matters in organic waste or biomass into gas and pure char by burning the fuel via it allows biomass in small-scaled engines and co-generation units ­ which with conventional technologies

Note: This page contains sample records for the topic "heaters wood stoves" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Integrated Datasets (IDs) Wood/Bretherton proposal  

E-Print Network [OSTI]

Integrated Datasets (IDs) Wood/Bretherton proposal ID Rationale Space/Time scale; Location; Platforms Parameters Combined Drizzle Dataset (CD ID) Collocated precipitation, aerosol and cloud micro, precip. rate, cloud Cross- Section Dataset (XS-ID) Data on E-W cross- section along 20°S from coast

Wood, Robert

482

Donald R. Woods, "Problem-based Learning: resources to gain the most from PBL," D.R. Woods, Waterdown, ON, ISBN 0-9698725-2-6, revised 1996  

E-Print Network [OSTI]

Donald R. Woods, "Problem-based Learning: resources to gain the most from PBL," D.R. Woods resource list Resources for PBL 1: D.R. Woods, Chemical Engineering, McMaster Univ. This is a background

Thompson, Michael

483

Donald R. Woods, "Problem-based Learning: resources to gain the most from PBL," D.R. Woods, Waterdown, ON, ISBN 0-9698725-2-6, revised 1996  

E-Print Network [OSTI]

Donald R. Woods, "Problem-based Learning: resources to gain the most from PBL," D.R. Woods-directed case example, A-19 A.1 Osterman feedback lecture For a description and some details see Woods (1991

Thompson, Michael

484

Impact of Ducting on Heat Pump Water Heater Space Conditioning Energy Use and Comfort  

SciTech Connect (OSTI)

Increasing penetration of heat pump water heaters (HPWHs) in the residential sector will offer an important opportunity for energy savings, with a theoretical energy savings of up to 63% per water heater and up to 11% of residential energy use (EIA 2009). However, significant barriers must be overcome before this technology will reach widespread adoption in the Pacific Northwest region and nationwide. One significant barrier noted by the Northwest Energy Efficiency Alliance (NEEA) is the possible interaction with the homes space conditioning system for units installed in conditioned spaces. Such complex interactions may decrease the magnitude of whole-house savings available from HPWH installed in the conditioned space in cold climates and could lead to comfort concerns (Larson et al. 2011; Kresta 2012). Modeling studies indicate that the installation location of HPWHs can significantly impact their performance and the resultant whole-house energy savings (Larson et al. 2012; Maguire et al. 2013). However, field data are not currently available to validate these results. This field evaluation of two GE GeoSpring HPWHs in the PNNL Lab Homes is designed to measure the performance and impact on the Lab Home HVAC system of a GE GeoSpring HPWH configured with exhaust ducting compared to an unducted GeoSpring HPWH during heating and cooling season periods; and measure the performance and impact on the Lab Home HVAC system of the GeoSpring HPWH with both supply and exhaust air ducting as compared to an unducted GeoSpring HPWH during heating and cooling season periods. Important metrics evaluated in these experiments include water heater energy use, HVAC energy use, whole house energy use, interior temperatures (as a proxy for thermal comfort), and cost impacts. This technical report presents results from the PNNL Lab Homes experiment.

Widder, Sarah H.; Petersen, Joseph M.; Parker, Graham B.; Baechler, Michael C.

2014-07-21T23:59:59.000Z

485

Microsoft Word - ASHRAE_Water Heater Paper_2010-11-24_Final_LBNL_.docx  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Energy Efficiency Design Options for Residential Water Heaters: Economic Impacts on Consumers Presented at: 2011 ASHRAE Winter Conference, Las Vegas, Nevada January 2011 Alex B. Lekov, Victor H. Franco, Steve Meyers, Lisa Thompson, and Virginie Letschert Lawrence Berkeley National Laboratory Environmental Energy Technologies Division One Cyclotron Road Berkeley, CA 94720 This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology, State, and Community Programs, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY 2 Disclaimer This document was prepared as an account of work sponsored by the United States

486

Advanced Process Heater for the Steel, Aluminum and Chemical Industries of the Future  

SciTech Connect (OSTI)

The Roadmap for Process Heating Technology (March 16, 2001), identified the following priority R&D needs: Improved performance of high temperature materials; improved methods for stabilizing low emission flames; heating technologies that simultaneously reduce emissions, increase efficiency, and increase heat transfer. Radiant tubes are used in almost every industry of the future. Examples include Aluminum re-heat furnaces; Steel strip annealing furnaces, Petroleum cracking/ refining furnaces, Metal Casting/Heat Treating in atmosphere and fluidized bed furnaces, Glass lair annealing furnaces, Forest Products infrared paper driers, Chemical heat exchangers and immersion heaters, and the indirect grain driers in the Agriculture Industry. Several common needs among the industries are evident: (1) Energy Reductions, (2) Productivity Improvements, (3) Zero Emissions, and (4) Increased Component Life. The Category I award entitled Proof of Concept of an Advanced Process Heater (APH) for Steel, Aluminum, and Petroleum Industries of the Future met the technical feasibility goals of: (1) doubling the heat transfer rates (2) improving thermal efficiencies by 20%, (3) improving temperature uniformity by 100oF (38 oC) and (4) simultaneously reducing NOx and CO2 emissions. The APH addresses EEREs primary mission of increasing efficiency/reducing fuel usage in energy intensive industries. The primary goal of this project was to design, manufacture and test a commercial APH prototype by integrating three components: (1) Helical Heat Exchanger, (2) Shared Wall Radiant U-tube, and (3) Helical Flame Stabilization Element. To accomplish the above, a near net shape powder ceramic Si-SiC low-cost forming process was used to manufacture the components. The project defined the methods for making an Advanced Process Heater that produced an efficiency between 70% to 80% with temperature uniformities of less than 5oF/ft (9oC/m). Three spin-off products resulted from this project: (1) a low-cost, high-temperature heat exchanger, (2) a new radiant heat transfer system, and (3) a hybrid or integral advanced process heater that incorporates a high surface area ceramic heat exchanger and burner combined with either a metallic or ceramic radiant tube and heat transfer elements.

Thomas D. Briselden

2007-10-31T23:59:59.000Z

487

2014-06-27 Issuance: Test Procedures for Residential and Commercial Water Heaters; Final Rule  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register final rule regarding test procedures for residential and commercial water heaters, as issued by the Deputy Assistant Secretary for Energy Efficiency on June 27, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

488

Control Strategy for Domestic Water Heaters during Peak Periods and its Impact on the Demand for Electricity  

Science Journals Connector (OSTI)

Because they store hot water, water heaters are easily-shifted loads that can be controlled to reduce peak demands. However, load shifting may have some detrimental consequences on the domestic hot water supply temperature if the heating element is deactivated for a long period of time. Furthermore, a new peak may be caused if a significant number of heaters are reactivated at the same time. This study presents a control strategy for water heaters that minimizes the pick-up demand when the heating elements are reactivated at the end of a load shifting period and that ensures, in all cases, the client's hot water supply. The study is based on a simulation model of a water heater that was experimentally validated and takes into account the diversity of the population's hot water withdrawal profile. More specifically, the data of 8,167 real water withdrawal profiles of several clients were input into the simulation model in order to evaluate the performance of water heaters under different operating conditions.

Alain Moreau

2011-01-01T23:59:59.000Z

489

Feasibility of Using Measurements of Internal Components ofTankless Water Heaters for Field Monitoring of Energy and Water Use  

SciTech Connect (OSTI)

The objective of this study was to determine if it was feasible to collect information regarding energy use and hot water delivery from tankless gas water heaters using the sensors and controls built into the water heaters. This could then be used to determine the water heater efficiency ? the ratio of energy out (hot water delivered) to energy in (energy in the gas) in actual residential installations. The goal was to be as unobtrusive as possible, and to avoid invalidating warranties or exposing researchers to liability issues. If feasible this approach would reduce the costs of instrumentation.This paper describes the limited field and laboratory investigations to determine if using the sensors and controls built into tankless water heaters is feasible for field monitoring.It was more complicated to use the existing gas flow, water and temperature sensors than was anticipated. To get the signals from the existing sensors and controls is difficult and may involve making changes that would invalidate manufacturer warrantees. The procedures and methods for using signals from the existing gas valves, water flow meters and temperature sensors will vary by model. To be able to monitor different models and brands would require detailed information about each model and brand.Based on these findings, we believe that for field monitoring projects it would be easier, quicker and safer to connect external meters to measure the same parameters rather than using the sensors and controls built into tankless water heaters.

Lutz, Jim; Biermayer, Peter

2008-04-17T23:59:59.000Z

490

Evaluation of Gas, Oil and Wood Pellet Fueled Residential Heating System Emissions Characteristics  

SciTech Connect (OSTI)

This study has measured the emissions from a wide range of heating equipment burning different fuels including several liquid fuel options, utility supplied natural gas and wood pellet resources. The major effort was placed on generating a database for the mass emission rate of fine particulates (PM 2.5) for the various fuel types studied. The fine particulates or PM 2.5 (less than 2.5 microns in size) were measured using a dilution tunnel technique following the method described in US EPA CTM-039. The PM 2.5 emission results are expressed in several units for the benefit of scientists, engineers and administrators. The measurements of gaseous emissions of O{sub 2}, CO{sub 2}, CO, NO{sub x} and SO{sub 2} were made using a combustion analyzer based on electrochemical cells These measurements are presented for each of the residential heating systems tested. This analyzer also provides a steady state efficiency based on stack gas and temperature measurements and these values are included in the report. The gaseous results are within the ranges expected from prior emission studies with the enhancement of expanding these measurements to fuels not available to earlier researchers. Based on measured excess air levels and ultimate analysis of the fuel's chemical composition the gaseous emission results are as expected and fall within the range provided for emission factors contained in the US-EPA AP 42, Emission Factors Volume I, Fifth Edition. Since there were no unexpected findings in these gaseous measurements, the bulk of the report is centered on the emissions of fine particulates, or PM 2.5. The fine particulate (PM 2.5) results for the liquid fuel fired heating systems indicate a very strong linear relationship between the fine particulate emissions and the sulfur content of the liquid fuels being studied. This is illustrated by the plot contained in the first figure on the next page which clearly illustrates the linear relationship between the measured mass of fine particulate per unit of energy, expressed as milligrams per Mega-Joule (mg/MJ) versus the different sulfur contents of four different heating fuels. These were tested in a conventional cast iron boiler equipped with a flame retention head burner. The fuels included a typical ASTM No. 2 fuel oil with sulfur below 0.5 percent (1520 average ppm S), an ASTM No. 2 fuel oil with very high sulfur content (5780 ppm S), low sulfur heating oil (322 ppm S) and an ultra low sulfur diesel fuel (11 ppm S). Three additional oil-fired heating system types were also tested with normal heating fuel, low sulfur and ultralow sulfur fuel. They included an oil-fired warm air furnace of conventional design, a high efficiency condensing warm air furnace, a condensing hydronic boiler and the conventional hydronic boiler as discussed above. The linearity in the results was observed with all of the different oil-fired equipment types (as shown in the second figure on the next page). A linear regression of the data resulted in an Rsquared value of 0.99 indicating that a very good linear relationship exits. This means that as sulfur decreases the PM 2.5 emissions are reduced in a linear manner within the sulfur content range tested. At the ultra low sulfur level (15 ppm S) the amount of PM 2.5 had been reduced dramatically to an average of 0.043 mg/MJ. Three different gas-fired heating systems were tested. These included a conventional in-shot induced draft warm air furnace, an atmospheric fired hydronic boiler and a high efficiency hydronic boiler. The particulate (PM 2.5) measured ranged from 0.011 to 0.036 mg/MJ. depending on the raw material source used in their manufacture. All three stoves tested were fueled with premium (low ash) wood pellets obtained in a single batch to provide for uniformity in the test fuel. Unlike the oil and gas fired systems, the wood pellet stoves had measurable amounts of particulates sized above the 2.5-micron size that defines fine particulates (less than 2.5 microns). The fine particulate emissions rates ranged from 22 to 30 mg/ MJ with an average value

McDonald, R.

2009-12-01T23:59:59.000Z

491

Blue - fern  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

fireplace, space heater, or free standing stove. A home with multiple electric heating systems A home with multiple heating systems and fuel types Extensive use of...

492

Calorific and porosity development in carbonized wood  

SciTech Connect (OSTI)

Wood of four species (red oak, southern yellow pine, black cherry, and hybrid poplar) were carbonized in a flowing nitrogen atmosphere at an average heating rate of 3 degrees Centigrade/minute to selected final temperatures up to 700 degrees Centigrade. The effects of final carbonization temperature on selected properties of the char were obtained using an adiabatic oxygen bomb calorimeter to investigate heat of combustion and a mercury porosimeter to investigate total porosity, real density, apparent density, and pore size distribution. Pore characteristics of carbonized wood developed before 300 degrees Centigrade in southern yellow pine and before 400 degrees Centigrade in red oak, black cherry, and hybrid poplar. Statistical analysis established linear relationships between heat of combustion versus final carbonization temperature in the carbonization temperature ranges investigated. The results of this study will aid in understanding optimum pryrolysis conditions for the development of calorific and porosity values. (Refs. 22).

Baileys, R.T.; Blankenhorn, P.R.

1982-07-01T23:59:59.000Z

493

Genomics of wood-degrading fungi  

Science Journals Connector (OSTI)

Abstract Woody plants convert the energy of the sun into lignocellulosic biomass, which is an abundant substrate for bioenergy production. Fungi, especially wood decayers from the class Agaricomycetes, have evolved ways to degrade lignocellulose into its monomeric constituents, and understanding this process may facilitate the development of biofuels. Over the past decade genomics has become a powerful tool to study the Agaricomycetes. In 2004 the first sequenced genome of the white rot fungus Phanerochaete chrysosporium revealed a rich catalog of lignocellulolytic enzymes. In the decade that followed the number of genomes of Agaricomycetes grew to more than 75 and revealed a diversity of wood-decaying strategies. New technologies for high-throughput functional genomics are now needed to further study these organisms.

Robin A. Ohm; Robert Riley; Asaf Salamov; Byoungnam Min; In-Geol Choi; Igor V. Grigoriev

2014-01-01T23:59:59.000Z

494

Synergy Effects of Wood Flour and Fire Retardants in Flammability of Wood-plastic Composites  

Science Journals Connector (OSTI)

Abstract Addition of wood flour improve the mechanical properties of thermoplastics, on the other hand it increases the burning speed of the materials. To modify the flammability of wood-plastic composites(WPC), various fire retardants, such as ammonium polysphosphate (APP), melamine polyphosphate (MPP) and aluminum hydroxide were added to WPCs. Burning tests based on UL94 and cone calorimetry were conducted to evaluate a fire performance of \\{WPCs\\} with fire retardants. The addition of fire retardants could lead to self-extinguishing materials when 10 wt% of APP was used. However, in the case of pure polypropylene, addition of 10 wt% of APP did not improve the flammability. Wood flour accelerates the burning behavior of PP, but it can reduce the use of APP to achieve self-extinguishing materials. Synergy effects between wood flour and APP was confirmed. Wood flour facilitates the forming of foamed char layer by APP during the combustion. This protective char surface can reduce the heat and oxygen diffusion toward the WPCs. The effect of fire retardants of mechanical properties of \\{WPCs\\} was also investigated. Tensile strength and modulus of composites decreased with addition of fire retardants.

Toshikazu Umemura; Yoshihiko Arao; Sakae Nakamura; Yuta Tomita; Tatsuya Tanaka

2014-01-01T23:59:59.000Z

495

Research and Design of a Sample Heater for Beam Line 6-2c Transmission X-ray Microscope  

SciTech Connect (OSTI)

There exists a need for environmental control of samples to be imaged by the Transmission X-Ray Microscope (TXM) at the SSRLs Beam Line 6-2c. In order to observe heat-driven chemical or morphological changes that normally occur in situ, microscopes require an additional component that effectively heats a given sample without heating any of the microscope elements. The confinement of the heat and other concerns about the heaters integrity limit which type of heater is appropriate for the TXM. The bulk of this research project entails researching different heating methods used previously in microscopes, but also in other industrial applications, with the goal of determining the best-fitting method, and finally in designing a preliminary sample heater.

Policht, Veronica; /Loyola U., Chicago /SLAC

2012-08-27T23:59:59.000Z

496

Page not found | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

11 - 21320 of 31,917 results. 11 - 21320 of 31,917 results. Article Wood and Pellet Heating Looking for an efficient, renewable way to heat your home? Wood or pellets are renewable fuel sources, and modern wood and pellet stoves are efficient heaters. http://energy.gov/energysaver/articles/wood-and-pellet-heating Download EAC Presentation: Comparison Among Three Studies (July 12, 2011) Presentation by L. T. Papay before the Electricity Advisorty Committee on July 12, 2011, analyzing three studies: http://energy.gov/oe/downloads/eac-presentation-comparison-among-three-studies-july-12-2011 Rebate Kansas- Net Metering Kansas adopted the Net Metering and Easy Connection Act in May 2009 (see K.S.A. 66-1263 through 66-1271), establishing net metering for customers of investor-owned utilities in Kansas. Net metering...

497

Feasibility of accompanying uncontrolled linear heater with solar system innatural gas pressure drop stations  

Science Journals Connector (OSTI)

Natural gas (NG) must be preheated before pressure reduction takes places at City Gate Stations (CGS). Indirect Water Bath Gas Heaters are employed in the CGS for preheating. The heaters consume a considerable amount of NG for preheating. As low temperature is required, a solar system has been proposed to provide part of heat demand. The system consists of a collector array and a storage tank. The tank stores solar heat during the day and releases it during the night. To show the capabilities of the proposed system, the Akand CGS has been chosen as a case study. The results show that as the number of collector increases, the fuel cost decreases but the capital cost increases. An optimum number of collectors and the storage tank capacity have been found based on economic analysis. The fuel saving occurs throughout the year with the maximum at June. The economic feasibility study of the proposed system has been carried out using two methods. These methods are Simple Payback Ratio (SPR) and (Net Present Value) NPV. The first one unveils that the payback ratio is only 6.9 years. The NPV method shows that the system will give net benefit after 11 years.

M. Farzaneh-Gord; A. Arabkoohsar; M. Deymi Dasht-bayaz; V. Farzaneh-Kord

2012-01-01T23:59:59.000Z

498

Modeling of Electric Water Heaters for Demand Response: A Baseline PDE Model  

SciTech Connect (OSTI)

Demand response (DR)control can effectively relieve balancing and frequency regulation burdens on conventional generators, facilitate integrating more renewable energy, and reduce generation and transmission investments needed to meet peak demands. Electric water heaters (EWHs) have a great potential in implementing DR control strategies because: (a) the EWH power consumption has a high correlation with daily load patterns; (b) they constitute a significant percentage of domestic electrical load; (c) the heating element is a resistor, without reactive power consumption; and (d) they can be used as energy storage devices when needed. Accurately modeling the dynamic behavior of EWHs is essential for designing DR controls. Various water heater models, simplified to different extents, were published in the literature; however, few of them were validated against field measurements, which may result in inaccuracy when implementing DR controls. In this paper, a partial differential equation physics-based model, developed to capture detailed temperature profiles at different tank locations, is validated against field test data for more than 10 days. The developed model shows very good performance in capturing water thermal dynamics for benchmark testing purposes

Xu, Zhijie; Diao, Ruisheng; Lu, Shuai; Lian, Jianming; Zhang, Yu

2014-09-05T23:59:59.000Z

499

Impact of Pilot Light Modeling on the Predicted Annual Performance of Residential Gas Water Heaters: Preprint  

SciTech Connect (OSTI)

Modeling residential water heaters with dynamic simulation models can provide accurate estimates of their annual energy consumption, if the units? characteristics and use conditions are known. Most gas storage water heaters (GSWHs) include a standing pilot light. It is generally assumed that the pilot light energy will help make up standby losses and have no impact on the predicted annual energy consumption. However, that is not always the case. The gas input rate and conversion efficiency of a pilot light for a GSWH were determined from laboratory data. The data were used in simulations of a typical GSWH with and without a pilot light, for two cases: 1) the GSWH is used alone; and 2) the GSWH is the second tank in a solar water heating (SWH) system. The sensitivity of wasted pilot light energy to annual hot water use, climate, and installation location was examined. The GSWH used alone in unconditioned space in a hot climate had a slight increase in energy consumption. The GSWH with a pilot light used as a backup to an SWH used up to 80% more auxiliary energy than one without in hot, sunny locations, from increased tank losses.

Maguire, J.; Burch, J.

2013-08-01T23:59:59.000Z

500

Analysis of thermal properties of basalt from heater Test No. 2 experiment  

SciTech Connect (OSTI)

Rockwell Hanford Operations is conducting a series of full-scale in situ tests at the Near Surface Test Facility (NSTF) near Richland, Washington as an integral part of the Basalt Waste isolation project. An objective of the Phase I tests, which include Main Heater Test No. 2, is to provide data for determination the material properties necessary for predicting the response of a repository system at depth. During the first 90 days Heater Test No. 2 represents the near-field response of a high-level waste canister which generates 1 kW of heat energy. The analysis of the thermal response of basalt from data collected during this initial heating period is described in this report. Values of thermal conductivity and heat capacity for basalt are determined using three methods referred to as type curve matching, Jacob's straight line method, and the Gauss-Newton parameter optimization method. Results indicate that the type curve and the Gauss-Newton methods give values which correspond relatively closely to those measured in the laboratory.

Huyakorn, P.; Williams, J.R.; Thomas, S. (GeoTrans, Inc., Reston, VA (USA); Applied Mechanics, Inc., Grand Junction, CO (USA); GeoTrans, Inc., Reston, VA (USA))

1981-10-04T23:59:59.000Z