Engineering computer models for refrigerators, freezers, furnaces, water heaters, room and central air conditioners  

SciTech Connect (OSTI)

This User's Guide provides the necessary information for understanding and using a computer model developed for the US Department of Energy which predicts the performance (energy consumption) of household refrigerators, refrigerator-freezers, and freezers. The model is capable of simulating various cabinet configurations (top-mount, bottom-mount, side-by-side, single-door) and refrigeration unit combinations (back-mounted static condenser with single forced convection evaporator, hot wall condenser with cooled wall panels, etc.). The program is comprised of two main subroutines: a cabinet heat-load submodel and a refrigeration unit submodel; they can be used separately for preliminary design analysis or together for performance evaluations. A technical description of the model and information on how to structure input parameters are provided. The user is provided with specific guidance for running the model on a computer. Specific instructions are given in the Appendices for changing and running the model using the operating language compatible with the DOE computer terminal system. Other users will have to modify the procedures in these sections as necessary for different computers.

Not Available

1982-11-01T23:59:59.000Z

2

Development of minimum efficiency standards for large capacity air conditioners, and commercial water heaters, refrigerators, and freezers. Final report  

SciTech Connect (OSTI)

The California Energy Resources Conservation and Development Commission has promulgated appliance energy efficiency standards and energy conservation standards for new construction with the objective of reducing energy consumption in the State of California. The following appliance categories are specifically addressed: large capacity air conditioners; commercial water heaters; and commercial refrigerators and freezers. The tasks that have been performed include: an energy use pattern study for the subject equipment; an examination of the size distribution of commercial air conditioning equipment; an examination of the different types of commercial air conditioning systems; an evaluation of the effectiveness of economizers in reducing commercial air conditioning system energy consumption in California; an examination of the effects of oversizing commercial air conditioners; a detailed study of supermarket refrigeration and air conditioning equipment; an evaluation of the economic feasibility of utilizing air conditioner waste heat to heat water; an assessment of the applicability of existing test procedures for small water heaters to large water heaters; and a brief investigation of the marketing and distribution systems for air conditioning and refrigeration equipment. Results of the efforts are described.

Merrill, P.S.; Rettberg, R.J.; Erickson, R.C.; Toor, J.S.

1980-05-01T23:59:59.000Z

3

Conservation Division regiulations for appliance-efficiency standards relating to refrigerators and freezers, room air conditioners, central air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances  

SciTech Connect (OSTI)

The text of the appliance efficiency standards for certain types of new appliances sold in California is presented. Specifications and test methods to identify complying refrigerators, freezers, air conditioners, gas space heaters, water heaters, plumbing fittings, gas clothes dryers, and gas cooking appliances are covered.

Not Available

1981-12-16T23:59:59.000Z

4

Superinsulation in refrigerators and freezers  

SciTech Connect (OSTI)

The results presented here were obtained during Phase 4 of the first CRADA, which had the specific objective of determining the lifetime of superinsulations when installed in simulated refrigerator doors. The second CRADA was established to evaluate and test design concepts proposed to significantly reduce energy consumption in a refrigerator-freezer that is representative of approximately 60% of the US market. The stated goal of this CRADA is to demonstrate advanced technologies which reduce, by 50%, the 1993 National Appliance Energy Conservation Act (NAECA) standard energy consumption for a 20 ft{sup 3} (570 L) top-mount, automatic-defrost, refrigerator-freezer. For a unit this size, the goal translates to an energy consumption of 1.003 kWh/d. The general objective of the research is to facilitate the introduction of efficient appliances by demonstrating design changes that can be effectively incorporated into new products. In previous work on this project, a Phase 1 prototype refrigerator-freezer achieved an energy consumption of 1.413 kWh/d [Vineyard, et al., 1995]. Following discussions with an advisory group comprised of all the major refrigerator-freezer manufacturers, several options were considered for the Phase 2 effort, one of which was cabinet heat load reductions.

Vineyard, E.; Stovall, T.K.; Wilkes, K.E.; Childs, K.W.

1998-02-01T23:59:59.000Z

5

Energy-efficiency directory of refrigerators and refrigerator-freezers  

SciTech Connect (OSTI)

Information is presented about the energy costs of operating refrigerators and refrigerator-freezers and includes the type of refrigerator or refrigerator-freezer, the fresh food volume, the freezer volume, the total volume, and the yearly energy cost. The directory lists all currently marketed electric refrigerators and refrigerator-freezers that have Energy Guide labels. The Federal Trade Commission requires manufacturers who distribute refrigerators and refrigerator-freezers to attach Energy Guide labels to appliances manufactured on or after May 19, 1980. The data have been measured by manufacturers and/or their agents according to US Government standard test procedures.

Statt, T.G.; Coggins, J.L.

1981-06-01T23:59:59.000Z

6

Refrigerator-Freezer Appendix A1 | Department of Energy  

Energy Savers [EERE]

Refrigerator-Freezer Appendix A1 Refrigerator-Freezer Appendix A1 Residential Refrigerator-Freezer Appendix A1 - v2.8.xlsx More Documents & Publications Refrigerators and...

7

Covered Product Category: Commercial Refrigerators and Freezers  

Broader source: Energy.gov [DOE]

The Federal Energy Management Program (FEMP) provides acquisition guidance for commercial refrigerators and freezers, which are covered by the ENERGY STAR program.

8

Energy use of US residential refrigerators and freezers: function derivation based on household and climate characteristics  

E-Print Network [OSTI]

residential refrigerators and freezers: function derivationsecond most-used) refrigerators, and freezers, and residualfor more efficient refrigerators and freezers, as well as

Greenblatt, Jeffery

2013-01-01T23:59:59.000Z

9

Refrigerator/freezer energy use: Measured values vs. simulation results  

SciTech Connect (OSTI)

The EPA Refrigerator Analysis (ERA) program was utilized in the engineering analysis performed to support the proposed refrigerator/freezer standards in the United States. In this paper the accuracy of the ERA program for predicting the energy consumption of domestic refrigerators, freezers, and refrigerator-freezers is studied by comparing the predicted energy consumption with the measured energy consumption.

Hakim, S.H.; Turiel, I. [Lawrence Berkeley National Lab., CA (United States). Energy and Environment Div.

1997-12-31T23:59:59.000Z

10

2014-04-10 Issuance: Test Procedures for Refrigerators, Refrigerator-Freezers, and Freezers; Final Rule  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register final rule regarding test procedures for residential refrigerators and freezers, as issued by the Deputy Assistant Secretary for Energy Efficiency on April 10, 2014.

11

APPLIANCE EFFICIENCY REGULATIONS FOR REFRIGERATORS AND FREEZERS  

E-Print Network [OSTI]

mobile equipment. (c) Central air conditioning heat pumps, regardless of capacity, except that requirements for central air conditioning heat pumps with cooling capacity of 135,000 Btu per hour or more#12;#12;APPLIANCE EFFICIENCY REGULATIONS FOR REFRIGERATORS AND FREEZERS ROOM AIR CONDITIONERS

12

Refrigerator-freezer energy testing with alternative refrigerants  

SciTech Connect (OSTI)

As a result of the Montreal Protocol that limits the production of ozone-depleting refrigerants, manufacturers are searching for alternatives to replace the R12 that is presently used in residential refrigerator-freezers. Before an alternative can be selected, several issues must be resolved. Among these are energy impacts, system compatibility, cost, and availability. In an effort to determine the energy impacts of some of the alternatives, energy consumption tests were performed in accordance with section 8 of the Association of Home Appliance Manufacturers (AHAM) standard for household refrigerators and household freezers. The results are presented for an 18 cubic foot (0.51 cubic meter), top-mount refrigerator-freezer with a static condenser using the following refrigerants: R12, R500, R12/Dimethyl-ether (DME), R22/R142b, and R134a. Conclusions from the AHAM test are that R500 and R12 /DME have a reduced energy consumption relative to R12 when replaced in the test unit with no modifications to the refrigeration system. Run times were slightly lower than R12 for both refrigerants indicating a higher capacity. While the R134a and R22/R142b results were less promising refrigeration system, such as a different capillary tube or compressor, may improve their performance. 12 refs., 2 figs., 3 tabs.

Vineyard, E.A.; Sand, J.R.; Miller, W.A.

1989-01-01T23:59:59.000Z

13

Factors affecting the energy consumption of two refrigerator-freezers  

SciTech Connect (OSTI)

Two refrigerator-freezers, one with a top-mounted freezer and one with side-by-side doors, were tested in the laboratory to determine the sensitivity of their energy consumption to various operational factors. Room temperature, room humidity, door openings, and the setting of the anti-sweat heater switch were the factors examined. The results indicated that the room temperature and door openings had a significantly greater effect on energy consumption than the other two factors. More detailed tests were then performed under different room temperature and door-opening combinations. The relationship of door openings and the equivalent test room temperature was established. Finally, the effect on energy of different temperature settings was studied. Test results are presented and discussed.

Kao, J.Y.; Kelley, G.E. [National Inst. of Standards and Technology, Gaithersburg, MD (United States). Building and Fire Research Lab.

1996-12-31T23:59:59.000Z

14

Refrigerator-freezer energy testing with alternative refrigerants  

SciTech Connect (OSTI)

As a result of the Montreal Protocol (UNEP 1987) that limits the production of ozone-depleting refrigerants, manufacturers are searching for alternatives to replace the R12 that is presently used in residential refrigerator-freezers. Before an alternative can be selected, several issues must resolved. Among these are energy impacts, system compatibility, cost, and availability, In an effort to determine the energy impacts of some of the alternatives, energy consumption tests were performed in accordance with section 8 of the Association of Home Appliance Manufacturers (AHAM) standard for household refrigerators and household freezers (AHAM 1985). The results are presented for an 18 ft{sup 3} (0.51 m{sup 3}), top mount refrigerators-freezer with a static condenser using the following refrigerants: R 12, R500, R12/dimethylether (DME), R22/R142b, and R134a. Conclusions from the AHAM test are that R500 and R12/DME have a reduced energy consumption relative to R12 when replaced in the test unit with no modifications to the refrigeration system. Run times were slightly lower than R12 for both refrigerants, indicating a higher capacity. While the R134a and R22/R142b results were less promising (6.8% and 8.5% higher energy consumption, respectively), changes to the refrigeration system, such as a different capillary tube or compressor, may improve their performance. It is noted that the test results are only an initial step in determining a replacement for R12.

Sand, J.R. (Oak Ridge National Lab., Oak Ridge, TN (US)); Vineyard, E.A.; Sand, J.R.

1989-01-01T23:59:59.000Z

15

Commercial Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Water Heaters Commercial Water Heaters Standardized DOE Testing Templates commercialwaterheater v1.0.xlsx More Documents & Publications Refrigerators and Refrigerator-Freezers...

16

DOE Resolves Avanti Refrigerator and Freezer Civil Penalty Case  

Broader source: Energy.gov [DOE]

Today, the Department of Energy announced that it has resolved the civil penalty action against Mackle Company for its failure to certify that refrigerators and refrigerator-freezers sold under the...

17

Synopsis of residential refrigerator/freezer alternative refrigerants evaluation  

SciTech Connect (OSTI)

The experimental testing on residential refrigerator/freezers (R/Fs) is summarized in this paper. R/F testing focused on two areas: alternative refrigerants and equipment configurations. The refrigerants evaluated consisted of single components, azeotropes, and zeotropes derived from hydrofluorocarbons (HFCs) and hydrocarbons (HCs). These refrigerants were evaluated in conventional and unconventional R/F designs. Major and minor design modifications were studied. Minor modifications consisted of various capillary tube lengths, door insulations, and compressors, while major modifications included two-evaporator and two-cycle R/F systems. Results obtained from testing the two-cycle system will be discussed in a later paper. This paper presents the experimental results of alternative technologies evaluated as replacements for ozone depleting chemicals.

Baskin, E. [Environmental Protection Agency, Research Triangle Park, NC (United States)

1998-12-31T23:59:59.000Z

18

6 Energy Saving Tips for Commercial Refrigerators and Freezers  

Office of Energy Efficiency and Renewable Energy (EERE)

To help businesses save energy and money, the Energy Department today announced new standards aimed at making commercial refrigerators and freezers. Here are just a few more tips to increase the energy efficiency of these appliances.

19

2014-10-06 DOE Certification, Compliance, and Enforcement Overview for Refrigerators, Refrigerator-Freezers, Freezers, Dehumidifiers, Room Air Conditioners, Clothes Washers, Clothes Dryers, and Dishwashers  

Broader source: Energy.gov [DOE]

This presentation provides an overview of DOE Certification, Compliance, and Enforcement for Refrigerators, Refrigerator-Freezers, Freezers, Dehumidifiers, Room Air Conditioners, Clothes Washers, Clothes Dryers, and Dishwashers. It was presented via webinar on October 6, 2014.

20

Performance of a two-cycle refrigerator/freezer using HFC refrigerants  

SciTech Connect (OSTI)

A two-cycle 18 ft{sup 3} (0.51 m{sup 3}) refrigerator/freezer was tested utilizing American National Standards Institute/Association of Home Appliance Manufacturers (ANSI/AHAM) standards for energy consumption testing. A 34.9% energy consumption reduction was realized for a 1984 model refrigerator/freezer (1020 kWh original energy use). This paper presents a proven method of reducing the current Department of Energy (DOE) minimum energy-efficiency standards for refrigerator/freezers to the proposed year 2001 standards utilizing existing technology. For a top-mount, frost-free refrigerator/freezer having the above volume, the current DOE minimum energy standard is 770 kWh/year, and the proposed DOE year 2001 standard is 530 kWh/year (a 31% reduction). Therefore, some significant reductions may be obtained by implementing the modifications discussed in this paper into newer refrigerator/freezer models. The paper gives an overview of the modifications implemented by a Danish university on a US refrigerator/freezer and presents experimental performance testing results of the refrigerator/freezer. The modifications will cause the refrigerator/freezer to be more expensive, but the performance enhancements should offset cost. No cost analysis is presented in this paper, but a detailed cost analysis of a two-cycle refrigerator/freezer is contained in a 1993 US Environmental Protection Agency (EPA) report (EPA 1993). The refrigerator/freezer was tested using four refrigerants and compressors. Two compressors and refrigerants were tested in the freezer cycle, and four were tested in the fresh food cycle.

Baskin, E.; Delafield, F.R.

1999-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Covered Product Category: Commercial Refrigerators and Freezers...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Beer-dispensing and direct draw units Glass frosters Deep well and bunker freezers. Open-air units, deli cases, prep tables, drawer cabinets, laboratory-grade products,...

22

Energy performance listings: Residential refrigerator/freezers  

SciTech Connect (OSTI)

The Energy Performance Listings series provides comparative information across manufacturers on products. The Refrigerator/Freezers Listings include more than 2900 models that meet or exceed federal standards contained in the Energy Conservation Program for Consumer Products. Information on model energy efficiency levels, performance characteristics, and manufacturer names permits easy selection of top-performing equipment. Each Energy Performance Listing includes an introductory section, two sections of model listings, and an appendix with manufacturer contacts. The first model-listing section presents information in descending order of efficiency for all manufacturers. These efficiency-ordered listings also include banners or symbols to identify voluntary efficiency thresholds for U.S. DOE/U.S. EPA`s Energy Star Program and U.S. DOE`s Federal Energy Management Program (FEMP). Products listed above each banner meet or exceed the efficiency level established by the Energy Star program. All models noted with the symbol meet or exceed FEMP levels. With these listings, users can quickly identify the most efficient product in a particular size range, identify products that meet the efficiency criteria of a specific program, or determine an efficiency threshold that will include a specific number of manufacturers. The second section of model listings presents products grouped by manufacturer and catalog number, allowing users to quickly find and identify performance information on specific models. Energy Performance Listings are tools that support purchasing and procurement by federal, state, and local governments and others, including utility companies, energy interest groups, and research organizations. The listings may be used for program design and planning purposes, equipment selection, specification, and purchasing decisions. The listings are a product of the Energy-Efficient Procurement Collaborative, Inc. and are available through NYSERDA.

NONE

1997-01-01T23:59:59.000Z

23

2014-07-10 Issuance: Test Procedures for Refrigerators, Refrigerator-Freezers, and Freezers; Final Rule Correction  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register final rule correction regarding test procedures for refrigerators, refrigerator-freezers, and freezers, as issued by the Deputy Assistant Secretary for Energy Efficiency on July 10, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

24

Removing Odors from Refrigerators and Freezers after Food has Spoiled  

E-Print Network [OSTI]

ER-005 6-06 Extension Family and Consumer Science Specialists The Texas A&M University System If food has spoiled in a refrigerator or freezer because of a power failure or some other reason, undesirable odors can develop. To eliminate these odors...

FCS Project Team - FDRM UNIT

2005-09-30T23:59:59.000Z

25

Product Refrigerator Freezer Fresh, in shell 4 to 5 weeks Don't freeze  

E-Print Network [OSTI]

Product Refrigerator Freezer Eggs Fresh, in shell 4 to 5 weeks Don't freeze Raw yolks, whites 2 recommended storage times are for quality only. Refrigerator & Freezer Storage Chart Product Refrigerator, opened 3 days Don't freeze unopened 10 days 1 year Mayonnaise, commercial Refrigerate after opening 2

Burke, Peter

26

Fridge of the future: Designing a one-kilowatt-hour/day domestic refrigerator-freezer  

SciTech Connect (OSTI)

An industry/government Cooperative Research and Development Agreement (CRADA) was established to evaluate and test design concepts for a domestic refrigerator-freezer unit that represents approximately 60% of the US market. The goal of the CRADA was to demonstrate advanced technologies which reduce, by 50 percent, the 1993 NAECA standard energy consumption for a 20 ft{sup 3} (570 I) top-mount, automatic-defrost, refrigerator-freezer. For a unit this size, the goal translated to an energy consumption of 1.003 kWh/d. The general objective of the research was to facilitate the introduction of cost-efficient technologies by demonstrating design changes that can be effectively incorporated into new products. A 1996 model refrigerator-freezer was selected as the baseline unit for testing. Since the unit was required to meet the 1993 NAECA standards, the energy consumption was quite low (1.676 kWh/d), thus making further reductions in energy consumption very challenging. Among the energy saving features incorporated into the original design of the baseline unit were a low-wattage evaporator fan, increased insulation thicknesses, and liquid line flange heaters.

Vineyard, E.A.; Sand, J.R.

1998-03-01T23:59:59.000Z

27

Energy consumption testing of innovative refrigerator-freezers  

SciTech Connect (OSTI)

The high ambient temperature of the Canadian Standards Association (CSA) and the AHAM/DOE Refrigerator-Freezer Energy Consumption Standards is intended to compensate for the lack of door openings and other heat loads. Recently published results by Meier and Jansky (1993) indicate labeled consumption overpredicting typical field consumption by 15%. In-house field studies on conventional models showed labeled consumption overpredicting by about 22%. The Refrigerator-Freezer Technology Assessment (RFTA) test was developed to more accurately predict field consumption. This test has ambient temperature and humidity, door openings, and condensation control set at levels intended to typify Canadian household conditions. It also assesses consumption at exactly defined compartment rating temperatures. Ten conventional and energy-efficient production models were laboratory tested. The RFTA results were about 30% lower than labeled. Similarly, the four innovative refrigerator-freezer models, when field tested, also had an average of 30% lower consumption than labeled. Thus, the results of the limited testing suggest that the RFTA test may be a more accurate predictor of field use. Further testing with a larger sample is recommended. Experimental results also indicated that some innovative models could save up to 50% of the energy consumption compared with similar conventional units. The technologies that contributed to this performance included dual compressors, more efficient compressors and fan motors, off-state refrigerant control valve, fuzzy logic control, and thicker insulation. The larger savings were on limited production models, for which additional production engineering is required for full marketability.

Wong, M.T.; Howell, B.T.; Jones, W.R. [Ontario Hydro Technologies, Toronto, Ontario (Canada); Long, D.L. [Statistical Solutions, Mississauga, Ontario (Canada)

1995-12-31T23:59:59.000Z

28

NASA advanced refrigerator/freezer technology development project overview  

SciTech Connect (OSTI)

NASA Lewis Research Center (LeRC) has recently initiated a three-year project to develop the advanced refrigerator/freezer (R/F) technologies needed to support future life and biomedical sciences space experiments. Refrigerator/freezer laboratory equipment, most of which needs to be developed, is enabling to about 75 percent of the planned space station life and biomedical science experiments. These experiments will require five different classes of equipment; three storage freezers operating at -20 C, -70 C and less than 183 C, a -70 C freeze-dryer, and a cryogenic (less than 183 C) quick/snap freezer. This project is in response to a survey of cooling system technologies, performed by a team of NASA scientists and engineers. The team found that the technologies required for future R/F systems to support life and biomedical sciences spaceflight experiments, do not exist at an adequate state of development and concluded that a program to develop the advanced R/F technologies is needed. Limitations on spaceflight system size, mass, and power consumption present a significant challenge in developing these systems. This paper presents some background and a description of the Advanced R/F Technology Development Project, project approach and schedule, general description of the R/F systems, and a review of the major R/F equipment requirements.

Cairelli, J.E.

1995-03-01T23:59:59.000Z

29

Refrigerator/freezer directory: sorted by type and volume, based on 1979 standards  

SciTech Connect (OSTI)

This directory identifies refrigerators, freezers and combinations thereof, that have been certified as complying with the regulations that became effective on November 3, 1979.

Not Available

1980-02-29T23:59:59.000Z

30

Combination cooler and freezer for refrigerating containers and food in outer space  

SciTech Connect (OSTI)

A refrigeration apparatus for cooling containers and food in the microgravity conditions of outer space is described comprising: (a) a housing defining a refrigeration compartment for supporting the containers in a container storage area and food in a refrigerated food storage area, and freezer compartment; (b) cold plate means within the refrigeration compartment for cooling the containers and food by conduction; (c) thermoelectric refrigeration means for maintaining the cold plates at temperatures which cool the contents of the refrigeration compartment, and the freezer compartment.

Rudick, A.G.

1988-04-19T23:59:59.000Z

31

Compressor calorimeter performance of refrigerant blends: Comparative methods and results for a refrigerator/freezer application  

SciTech Connect (OSTI)

A protocol was developed to define calorimeter operating pressures for nonazeotropic refrigerant mixtures (NARMs) which corresponded with the saturated evaporator and condenser temperatures commonly used for pure refrigerants. Compressor calorimeter results were obtained using this equivalent-mean-temperature (EMT) approach and a generally applied Association of Home Appliance Manufacturers (AHAM) procedure at conditions characteristic of a domestic refrigerator-freezer application. Tests with R-12 and two NARMs indicate that compressor volumetric and isentropic efficiencies are nearly the same for refrigerants with similar capacities and pressure ratios. The liquid-line temperature conditions specified in the AHAM calorimeter rating procedure for refrigerator-freezer compressors were found to preferentially derate NARM performance relative to R-12. Conversion of calorimeter data taken with a fixed liquid-line temperature to a uniform minimal level of condenser subcooling is recommended as a fairer procedure when NARMs are involved. Compressor energy-efficiency-ratio (EER) and capacity data measured as a result of the EMT approach were compared to system performance calculated using an equivalent-heat-exchanger-loading (EHXL) protocol based on a Lorenz-Meutzner (L-M) refrigerator-freezer modeling program. The EHXL protocol was used to transform the calorimeter results into a more relevant representation of potential L-M cycle performance. The EMT method used to set up the calorimeter tests and the AHAM liquid-line conditions combined to significantly understate the cycle potential of NARMs relative to that predicted at the more appropriate EHXL conditions. Compressor conditions representative of larger heat exchanger sizes were also found to give a smaller L-M cycle advantage relative to R-12.

Rice, C K; Sand, J R

1993-01-01T23:59:59.000Z

32

Adapted from FDA refrigerator and freezer guidelines: http://www.fda.gov/downloads/Food/ResourcesForYou/HealthEducators/UCM109315.pdf Have you ever wondered how long you should keep things in the refrigerator or freezer? If so, then the chart below can he  

E-Print Network [OSTI]

Adapted from FDA refrigerator and freezer guidelines: http://www.fda.gov/downloads/Food/ResourcesForYou/HealthEducators/UCM109315.pdf Have you ever wondered how long you should keep things in the refrigerator or freezer? If so to preserve quality. Refrigerator & Freezer Storage Chart Product Refrigerator Freezer Product Refrigerator

33

The alternative refrigerant dilemma for refrigerator-freezers: Truth or consequences  

SciTech Connect (OSTI)

In an effort to select a refrigerant that has minimal impact on energy consumption and the environment, a screening analysis of potential refrigerants was performed that resulted in the selection of six candidates. The screening results show that R-134a, R-134, R-152a, R-134a/R-152a, R-22/R-152a/R-124, and R-134a/R-152a/R-124 are the most promising refrigerants based on the following criteria: ozone depletion potential, greenhouse warming potential, coefficient of performance, and safety. Energy consumption tests were performed for the three pure refrigerants in accordance with the Association of Home Appliance Manufacturers standard for household refrigerators and household freezers. The results indicate an increased energy consumption of 6.8%, 7.3%, and 7.3%, respectively for R-134, R-152a, and R-134a in the most efficient oil. However, when the effects of compressor efficiency are taken into account, the normalized energy consumption results in an increase of only 2.7% for R-152a and 5.5% for both R-134a and R-134. 14 refs., 5 tabs.

Vineyard, E.A.

1991-01-01T23:59:59.000Z

34

Review of energy efficiency of refrigerator/freezer gaskets. Final report, Jul-Nov 90  

SciTech Connect (OSTI)

The report gives results of an investigation of the significance of heat leakage through gaskets in household refrigerator/freezers, explores different design features, and suggests further study if necessary. The report gives results of an extensive literature review, interviews with refrigerator/freezer and gasket manufacturers, and some engineering analysis. (NOTE: Home refrigerators are the largest consumers of electricity among household appliances and are consuming an estimated 8% of the total electricity used in the U.S. Recent studies show that gasket area heat leakage may account for as much as 21% of the total thermal load.)

Ghassemi, M.; Shapiro, H.

1991-10-01T23:59:59.000Z

35

Evaluation of ozone-friendly hydrofluoropropane-based zeotropic refrigerant mixtures in a Lorenz-Meutzner refrigerator/freezer  

SciTech Connect (OSTI)

The design of the Lorenz-Meutzner refrigerator/freezer has two evaporators (located in the freezer and fresh food compartments), which makes it a leading candidate for use of zeotropic refrigerant mixtures. Zeotropic mixtures can have significant temperature glides during evaporation and condensation. Performance of the zeotropic mixture can be maximized in the LM design by permitting the lower end of the temperature glide to occur in the freezer compartment evaporator and the higher end in the fresh food compartment evaporator. Several hydrofluoropropane-based zeotropes (e.g., R-227 ea/R-245ca) have been shown through steady-state modeling to outperform R-134a by up to 15%. Results from previous testing of this refrigerator/freezer using R-32/R-124 (zeotropic mixture) were published in an ASHRAE paper (Sand et al. 1993). Their results showed performance gains of approximately 3% over R-12. In the study presented in this paper, the Lorenz-Meutzner refrigerator/freezer having two evaporators and two intercoolers was experimentally tested in an environmental chamber according to Association of Home Appliance Manufacturers/Department of Energy (AHAM/DOE) testing standards using several hydrofluoropropane-based zeotropic mixtures. The results are compared to baseline testing with R-134a. The R-245ca/R-134a and R-245ca/R-152a mixtures performed comparably to R-134a. R-245ca/R-270 outperformed all zeotropic mixtures and R-134a by at least 16%. Also, a refrigerant sampling loop is added to determine the running composition of the mixture and its effects on the performance of the refrigerator/freezer.

Baskin, E. [Environmental Protection Agency, Research Triangle Park, NC (United States); Bayoglu, E.S.; Delafield, F.R. [Acurex Environmental Corp., Durham, NC (United States)

1997-12-31T23:59:59.000Z

36

Cost-efficiency analysis in support of the energy conservation standards for refrigerator/freezers  

SciTech Connect (OSTI)

The National Appliance Energy Conservation At (NAECA) of 1987 requires the Department of Energy (DOE) to consider new or amended energy-efficiency standards for refrigerators and freezers along with several other appliances. This paper describes the cost-efficiency analysis of design options carried out in support of the proposed 1998 standards for refrigerator/freezers. These proposed standards are unique in that they have been reached by a consensus of various interested parties including the trade association of refrigerator and freezer manufacturers, environmental groups, state energy offices, and utility companies. In large part, these consensus standards are based on the analysis described in this paper. The analysis shows that, for example, for a 515-liter (18.2-ft{sup 3}) top-mount automatic-defrost refrigerator-freezer, the annual energy consumption can be reduced from 700 kWh/yr (2.52 GJ/yr) to 484 kWh/yr (1.74 GJ/yr) (30.9%) by the use of more efficient fan motors and compressors, improved gaskets, and insulation that is {1/2}-inch (12.7 mm) thicker. The energy use can be further reduced to 422 kWh/yr (1.52 GJ/yr) (39.8%) by employing improved heat exchangers, switching to adaptive defrost, and employing vacuum panel insulation instead of thicker walls and doors.

Hakim, S.H.; Turiel, I. [Lawrence Berkeley National Lab., CA (United States). Energy and Environment Div.

1996-12-31T23:59:59.000Z

37

Field usage and its impact on energy consumption of refrigerator/freezers  

SciTech Connect (OSTI)

This study investigated the effect of door openings and kitchen environment on the energy consumption of nine household refrigerator/freezers (R/Fs) in the field. The factors under consideration include fresh food and freezer door openings, length of door openings, ambient kitchen temperature, and kitchen relative humidity (RH). Average daily energy consumption for the nine units ranged from 1.7 to 5.3 kWh/day. Energy consumption was found to correlate with kitchen temperature and the number of door openings. No dependence on kitchen relative humidity was found. In general, the magnitude of the door opening component of energy consumption was higher for the more efficient units.

Gage, C.L. [Environmental Protection Agency, Research Triangle Park, NC (United States). Air Pollution Prevention and Control Div.

1995-12-31T23:59:59.000Z

38

An experimental analysis of cycling losses in domestic refrigerator-freezers  

SciTech Connect (OSTI)

This paper identifies and quantifies the cycling losses in a domestic refrigerator-freezer. During cycling operation the refrigerator was found to operate between 5% and 25% less efficiently than the corresponding quasi-steady machine. The cycling refrigerator operates with an evaporator capacity between 3% and 17% less than that of the quasi-steady refrigerator while at the same time requiring between 1% and 9% more power to operate. This refrigerator performance degradation was attributed to several factors, the most important being the refrigerant migration and the thermal mass of the evaporator and compressor. During the off-cycle, refrigerant migrates from the condenser to the evaporator as the system pressures equalize. The off-cycle migration increases the temperature of the evaporator and necessitates refrigerant redistribution during the on-cycle and thereby tends to reduce system performance. The increased power requirements, traced to the compressor, result from slight differences in system pressure and the reduced compressor efficiency due to a cool compressor. With the cycling losses identified, several possible refrigerator design changes were suggested. It appears that a refrigerator equipped with a reciprocating compressor, solenoid valves to isolate the condenser, and no accumulator should operate in a nearly quasi-steady manner.

Coulter, W.H. [DuPont Co., Belle, WV (United States); Bullard, C.W. [Univ. of Illinois, Urbana, IL (United States). Air Conditioning and Refrigeration Center

1997-12-31T23:59:59.000Z

39

Europe’s Most Energy Efficient Refrigerator-Freezers — the European Countries Working Together on the Forefront of the Market  

Science Journals Connector (OSTI)

This paper presents the outcome and the lessons learned from the first round of the Energy+ procurement project of refrigerator-freezers carried out ... project, that was preceded by a thorough market study, is t...

Anna Engleryd; Sophie Attali

2001-01-01T23:59:59.000Z

40

Simulating effects of multispeed compressors on refrigerator/freezer performance  

SciTech Connect (OSTI)

Simulation analyses suggest that a multispeed compressor could increase steady-state operating efficiency by 4% to 14%. An additional 0.5% to 4% energy savings might be obtained from the reduction in the cycling frequency of the refrigerator. Several aspects of the robustness of the capillary tube-suction line heat exchanger design for the two-speed compressor system were also examined with the simulation model. It was shown that a system optimized for low-speed operation, when operating at the high speed, could have as much capacity as the original base case high-speed system. A relatively simple control strategy was proposed, one that requires measurement of on-cycle time and one or two compartment air temperatures. The effects of varying the speed of the evaporator or condenser fans at both compressor speeds were examined over a range of ambient temperatures. One energy-saving scenario was identified: decreasing the condenser fan speed for refrigerators operating at low ambient temperatures. By affecting the distribution of refrigerant change throughout the system, the decrease in condenser fan speed reduces the superheat in the evaporator and increases the overall UA of the evaporator. The resulting increase in evaporator capacity more than offsets the decrease in condenser UA and the energy use of the refrigerator is decreased.

Woodall, R.J. [International Paper Technology, Mobile, AL (United States); Bullard, C.W. [Univ. of Illinois, Urbana, IL (United States). Air Conditioning and Refrigeration Center

1997-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Technical support document: Energy efficiency standards for consumer products: Refrigerators, refrigerator-freezers, and freezers including draft environmental assessment, regulatory impact analysis  

SciTech Connect (OSTI)

The Energy Policy and Conservation Act (P.L. 94-163), as amended by the National Appliance Energy Conservation Act of 1987 (P.L. 100-12) and by the National Appliance Energy Conservation Amendments of 1988 (P.L. 100-357), and by the Energy Policy Act of 1992 (P.L. 102-486), provides energy conservation standards for 12 of the 13 types of consumer products` covered by the Act, and authorizes the Secretary of Energy to prescribe amended or new energy standards for each type (or class) of covered product. The assessment of the proposed standards for refrigerators, refrigerator-freezers, and freezers presented in this document is designed to evaluate their economic impacts according to the criteria in the Act. It includes an engineering analysis of the cost and performance of design options to improve the efficiency of the products; forecasts of the number and average efficiency of products sold, the amount of energy the products will consume, and their prices and operating expenses; a determination of change in investment, revenues, and costs to manufacturers of the products; a calculation of the costs and benefits to consumers, electric utilities, and the nation as a whole; and an assessment of the environmental impacts of the proposed standards.

NONE

1995-07-01T23:59:59.000Z

42

Space Heaters, Computers, Cell Phone Chargers: How Plugged In Are Commercial Buildings?  

E-Print Network [OSTI]

Refrigerators, Refrigerator-Freezers & Freezers. DOE/EE-refrigerator, commercial speakers switch, ethernet freezer,refrigerator, microscope, autoclave, shaker/stirrer, lab freezer,

Sanchez, Marla; Webber, Carrie; Brown, Richard; Busch, John; Pinckard, Margaret; Roberson, Judy

2007-01-01T23:59:59.000Z

43

Waste-heat-driven refrigeration plants for freezer trawlers  

SciTech Connect (OSTI)

An analysis is made of the possibility of utilizing waste heat from a proposed gas-turbine fishing-vessel propulsion engine to power a refrigeration plant. On the basis of superior volume, maintenance and reliability, and cost and availability, the ammonia-water absorption system is chosen over the other waste-heat-driven option considered. It is found to be comparable in volume and in maintenance and reliability to the conventional vapor-compression system.

Kellen, A.D.

1986-01-01T23:59:59.000Z

44

Field test of a high efficiency, automatic defrost refrigerator-freezer  

SciTech Connect (OSTI)

This paper describes the market evaluation and field test portion of a program to design, develop, and demonstrate a high efficiency, automatic defrosting refrigerator-freezer for the residential market. After the successful completion of Phase I of the program, which concentrated on the design, construction, and laboratory testing of a 453 1 (16 ft/sup 3/) high-efficiency refrigerator-freezer prototype, Phase II was initiated in February 1979 to evaluate the sales potential and performance of the high-efficiency refrigerator concept under field conditions, as a necessary step in creating a product that was both manufacturable and marketable. In Phase I, a survey of food consumption and storage trends, family size, and consumer buying habits led to a sales-weighted average-capacity forecast for 1985 of approximately 453 1 (16 ft/sup 3/) and identification of the top-mount, automatic defrosting refrigerator as the projected sales leader. To meet this market demand, a 453 1 (16 ft/sup 3/) top-mount was selected as the baseline for the Phase I design and development. In Phase II, a 509 1 (18 ft/sup 3/) unit using Phase I technology was chosen for the field test, since the slightly larger model better fit the participating manufacturer's new product development efforts and market.

Topping, R.F.; Vineyard, E.A.

1982-01-01T23:59:59.000Z

45

Energy efficiency improvements for refrigerator/freezers using prototype doors containing gas-filled panel insulating systems  

SciTech Connect (OSTI)

Energy efficiency improvements in domestic refrigerator/freezers, are directly influenced by the overall thermal performance of the cabinet and doors. An advanced system for reducing heat gain is Gas-Filled Panel thermal insulation technology. Gas-Filled Panels contain a low-conductivity, inert gas at atmospheric pressure and employ a reflective baffle to suppress radiation and convection within the gas. This paper presents energy use test results for a 1993 model 500 liter top mount refrigerator/freezer operated with its original doors and with a series of alternative prototype doors. Gas-Filled Panel technology was used in two types of prototype refrigerator/freezer doors. In one design, panels were used in composite with foam in standard metal door pans; this design yielded no measurable energy savings. In the other design, special polymer door pans were fitted with panels that fill nearly all of the available insulation volume; this design yielded a 6.5% increase in energy efficiency for the entire refrigerator/freezer. The EPA Refrigerator Analysis computer program has been used to predict the change in daily energy consumption with the alternative doors. The computer model also projects a 25% energy efficiency improvement for a refrigerator/freezer that would use Gas-Filled Panel insulation throughout the cabinet as well as the doors.

Griffith, B.; Arasteh, D.; Tuerler, D.

1995-01-01T23:59:59.000Z

46

2014-06-23 Issuance: Energy Conservation Standards for Walk-in Coolers and Freezers; Air-Conditioning, Heating, & Refrigeration Institute Petition for Reconsideration  

Broader source: Energy.gov [DOE]

This document is the agency response to the Energy Conservation Standards for Walk-in Coolers and Freezers; Air-Conditioning, Heating, & Refrigeration Institute Petition for Reconsideration.

47

EPA's research projects relating to the dual-circuit and Lorenz refrigerator/freezers  

SciTech Connect (OSTI)

The paper discusses EPA research projects relating to the dual-circuit and Lorenz refrigerator/freezers (RFs). EPA is interested in not only phasing out chlorofluorocarbons (CFCs) in RFs, but doing so in a way that will maximize energy efficiency and minimize subsequent impacts on the greenhouse effect. An early decision was made to concentrate on replacing fully halogenated CFCs in RFs during the first year of EPA's research. RFs were chosen because they are small, require small quantities of refrigerants, are relatively easy to modify and test, and are the most energy-consumptive appliances in most U.S. households. In the future, other applications are expected to receive more attention. The first year of EPA's program has concentrated on implementing two alternative configurations of RFs which are believed to have the potential to make RFs more energy efficient: the dual-circuit and the Lorenz RFs. Research has included modeling alternative refrigerants and Non-azeotropic Refrigerant Mixtures (NARMs) in the dual-circuit and Lorenz configurations and experimental testing of modified RFs and refrigeration components in test stands.

Bare, J.C.

1992-01-01T23:59:59.000Z

48

An experimental study on new egg-crate type evaporators in domestic refrigerators and freezers  

SciTech Connect (OSTI)

This paper presents experimental results of the heat transfer performance of new egg-crate type evaporators that are becoming popular in vapor compression cycle-based modern refrigerators and freezers. These forced flow, multiple finned evaporators are preferred in the local industry over the older roll-bonded designs due to efficiency and cost considerations. Extensive testing was done, and experimental data were gathered on evaporators of three different sizes at three airflow rates using a closed-loop test rig built for the purpose. This has led to the development of a novel approach of measuring low air velocities as encountered in domestic refrigerators. A correlation has been developed for the heat transfer performance of these evaporators following the j-Colburn factor analysis. The correlation relates the j-Colburn factor, a nondimensional heat transfer grouping of the Nusselt number, Reynolds number, and Prandtl number to the Reynolds number and finning factor.

Bansal, P.K. [Univ. of Auckland (New Zealand). Dept. of Mechanical Engineering; Neuren, O.S. van [OPUS International Consultants, Ltd., Auckland (New Zealand)

1998-12-31T23:59:59.000Z

49

Field test of a high-efficiency, automatic-defrost refrigerator-freezer  

SciTech Connect (OSTI)

Following the successful design, development, and demonstration of a high efficiency refrigerator-freezer prototype, work was done to design and manufacture pre-production units for home usage tests. The purpose of the field test and the associated market evaluation is to confirm the energy saving potential of the high-efficiency design, identify possible design deficiencies or service difficulties, and assess the consumer appeal of the new unit. The first five months of field test data have shown an average 57% decrease in energy consumption when compared to a baseline unit of convention design. This energy savings is larger than predicted by the standard DOE test procedure. No serious design or service problems have been encountered. Consumers have not been adversely affected by the larger cabinet and thicker doors, and responded favorably in an actual retail sales test to initially spending more for an energy-saving refrigerator that will reduce electric usage.

Topping, R.F.; Vineyard, E.A.

1982-01-01T23:59:59.000Z

50

End-Use Load and Consumer Assessment Program: Analysis of residential refrigerator/freezer performance  

SciTech Connect (OSTI)

The Bonneville Power Administration (Bonneville) is conducting a large end-use data acquisition program in an effort to understand how energy is utilized in buildings with permanent electric space heating equipment in the Pacific Northwest. The initial portion of effort, known as the End-Use Load and Consumer Assessment Program (ELCAP), was conducted for Bonneville by the Pacific Northwest Laboratory (PNL). The collection of detailed end-use data provided an opportunity to analyze the amount of energy consumed by both refrigerators and separate freezers units located in residential buildings. By obtaining this information, the uncertainty of long- term regional end-use forecasting can be improved and potential utility marketing programs for new appliances with a reduced overall energy demand can be identified. It was found that standby loads derived from hourly averages between 4 a.m. and 5 a.m. reflected the minimum consumption needed to maintain interior refrigerator temperatures at a steady-state condition. Next, an average 24-hour consumption that included cooling loads from door openings and cooling food items was also determined. Later, analyses were conducted to develop a model capable of predicting refrigerator standby loads and 24-hour consumption for comparison with national refrigerator label ratings. Data for 140 residential sites with a refrigeration end-use were screened to develop a sample of 119 residences with pure refrigeration for use in this analysis. To identify those refrigerators that were considered to be pure (having no other devices present on the circuit) in terms of their end-use classification, the screening procedure used a statistical clustering technique that was based on standby loads with 24-hour consumption. 5 refs., 18 figs., 4 tabs.

Ross, B.A.

1991-09-01T23:59:59.000Z

51

Evaluation of design options for improving the energy efficiency of an environmentally safe domestic refrigerator-freezer  

SciTech Connect (OSTI)

In order to reduce greenhouse emissions from power plants and respond to regulatory actions arising from the National Appliance Energy Conservation Act (NAECA), several design options were investigated for improving the energy efficiency of a conventionally designed, domestic refrigerator-freezer. The options, such as improved cabinet insulation and high-efficiency compressor and fans, were incorporated into a prototype refrigerator-freezer cabinet and refrigeration system to produce a unit that is superior from an environmental viewpoint due to its lower energy consumption and the use of refrigerant HFC-134a as a replacement for CFC-12. Baseline energy performance of the original 1993 production refrigerator-freezer, along with cabinet heat load and compressor calorimeter test results, were extensively documented to provide a firm basis for experimentally measured energy savings. A detailed refrigerator system computer model was used to evaluate the energy savings for several design modifications that, collectively, could achieve a targeted energy consumption of 1.00 kWh/d for a 20 ft{sup 3} (570 l) top-mount, automatic-defrost, refrigerator-freezer. The energy consumption goal represents a 50% reduction in the 1993 NAECA standard for units of this size. Following the modeling simulation, laboratory prototypes were fabricated and tested to experimentally verify the analytical results and aid in improving the model in those areas where discrepancies occurred. While the 1.00 kWh/d goal was not achieved with the modifications, a substantial energy efficiency improvement of 22% (1.41 kWh/d) was demonstrated using near-term technologies. It is noted that each improvement exacts a penalty in terms of increased cost or system complexity/reliability. Further work on this project will analyze cost-effectiveness of the design changes and investigate alternative, more-elaborate, refrigeration system changes to further reduce energy consumption.

Vineyard, E.A.; Sand, J.R. [Oak Ridge National Lab., TN (United States); Bohman, R.H.

1995-03-01T23:59:59.000Z

52

Evaluation of performance and composition shift of zeotropic mixtures in a Lorenz-Meutzner refrigerator/freezer  

SciTech Connect (OSTI)

Results from previous testing of this refrigerator/freezer using a 750 Btu/h compressor and several zeotropic mixtures revealed a performance enhancement up to 16% above that of hydrofluorocarbon R-134a. In the study presented in this paper, the Lorenz-Meutzner (LM) refrigerator/freezer equipped with a 1060 Btu/h compressor, two evaporators, and two intercoolers was experimentally tested in an environmental chamber according to the Association of Home Appliance Manufacturers/Department of Energy (AHAM/DOE) testing standards using several hydrofluoropropane-based zeotropic mixtures. The results are compared to baseline testing with R-134a and results obtained using the 750 Btu/h compressor. Hydrofluorocarbons R-245ca/R-152a performed comparably to R-134a. R-245ca/hydrocarbon R-270 (cyclopropane C{sub 3}H{sub 6}) outperformed all zeotropic mixtures and R-134a by at least 12.2 {+-} 0.7%. All refrigerants performed better using the larger compressor due to its inherently better efficiency. Refrigerant samples taken during refrigerator/freezer operation revealed substantial composition shifts (e.g., a 30% running composition shift of R-134a in the R-245ca/R-134a mixture). Sand et al. (1993) obtained an approximately 20% energy reduction using steady-state on-cycle energy consumption results; a comparison was made between chlorofluorocarbon R-12 and a hydrofluorocarbon R-32/hydrochlorofluorocarbon R-124 mixture. Lorenz and Meutzner (1975), originators of the Lorenz-Meutzner refrigerator/freezer design, state that the following parameters influence the optimum performance of the design: (1) heat exchanger size, (2) capillary tube length, (3) refrigerant charge, and (4) compressor size. This work investigates three of these parameters--capillary tube length, compressor size, and refrigerant charge.

Baskin, E.; Smith, N.D.; Delafield, F.R.; Tufts, M.W.

1999-07-01T23:59:59.000Z

53

Developing cost curves for conserved energy in new refrigerators and freezers: Demonstration of methodology and detailed engineering results  

SciTech Connect (OSTI)

This paper develops and demonstrates a procedure for determining the cost of conserved energy in residential refrigerators and freezers and for ranking conservation measures according to economic feasibility and practicality. Prepared jointly by the Natural Resources Defense Council and ACEE for the Solar Energy Research Institute.

Goldstein, D.; Miller, P.; Watson, R.

1987-01-01T23:59:59.000Z

54

EPA's research projects relating to the dual-circuit and Lorenz refrigerator/freezers  

SciTech Connect (OSTI)

At a meeting in February 1989, EPA presented to several research universities, national laboratories, and refrigerator/freezer (RF) manufacturers the Agency's desire to replace CFC-12 as a refrigerant in the RF vapor compression cycle and increase RF energy efficiency. EPA recognized that, while eliminating CFCs, energy benefits could be gained by further product development (e.g., improving compressor efficiency or heat transfer surface areas). The largest cycle energy gains, however, were expected to be a result of completely different vapor compression configuration. Two new vapor compression configurations were suggested by the participants - the Lorenz design and the dual-circuit design. A decision was made to construct and test modified RFs as proof that the advanced refrigerants and cycles could achieve energy gains. An RF computer model has been updated and expanded which can model both the Lorenz and dual-circuit RF. Modified RF testing and component testing in test stands is being performed to determine the increased energy performance of these configurations.

Bare, J.C. (Environmental Protection Agency, Research Triangle Park, NC (United States))

1992-01-01T23:59:59.000Z

55

Refrigerator: Refrigerators and freezers are not typically constructed to assure that there is no  

E-Print Network [OSTI]

and unstable chemicals only be stored in a lab-safe refrigeration unit that meets National Fire Protection Association 45 ­ Standard on Fire Protection for Laboratories Using Chemicals. #12;Hearing conservation protection which will be furnished by the Institute. Samples of various types of ear muffs, ear caps, and ear

Cohen, Robert E.

56

Experimental results of a household automatic icemaker in a refrigerator/freezer  

SciTech Connect (OSTI)

This paper describes the performance test results of an automatic icemaker refrigerator under various modes of icemaker operation. The tests were conducted on a 20-ft{sup 3} (0.566-m{sup 3}) household refrigerator that had a single forced convection evaporator and was charged with R-12. The focus of the research was to ascertain the effect of icemaker operation on the refrigerator`s daily energy consumption. Thus, three different types of tests were conducted, depending upon the icemaker`s operating mode. In the first test type, the baseline, the automatic icemaker was turned off and no ice was made. In the second test type, the ice-making mode (test A), the icemaker was turned on and ice was continuously made. Compared to the baseline, additional power was intermittently consumed by a mold heater that melts the ice cubes` interface with the tray, a solenoid valve that supplies water to the icemaker tray, and a motor that rotates the ejector blades to press the crescent-shaped ice cubes out of the mold and unload them into an ice bin. In the third test type, the failure mode (test B), the water supply was manually disconnected but the icemaker was left turned on. Even though no ice was made, additional power was still consumed by the mold heater, the solenoid valve, and the motorized ejector. In tests A and B, the energy consumed by the icemaker`s components increases the cooling load, which raises the compressor power consumption. The present study shows that at the AHAM-specified test conditions, uninterrupted icemaking increased the daily energy consumption by 22.5% to 27.2%.

Haider, I.; Feng, H.; Radermacher, R. [Univ. of Maryland, College Park, MD (United States). Center for Environmental Energy Engineering

1996-12-31T23:59:59.000Z

57

Environmental assessment for proposed energy conservation standards for two types of consumer products; refrigerators, refrigerator-freezers, and freezers; small gas furnaces; and a proposed No standard standard for television sets  

SciTech Connect (OSTI)

This environmental assessment (EA) evaluates the environmental impacts resulting from new or amended energy-efficiency standard for refrigerators, refrigerator-freezers, freezers, small gas furnaces, and television sets as mandated by the National Appliance Energy Conservation Act of 1987. A complete description of the Engineering and Economic Analysis of the proposed standards may be found elsewhere in the Technical Support Document (TSD). Four of the 14 scenarios for product design changes described in the Engineering Analysis of the TSD are chosen for environmental assessment based on their relative importance as design measures. Values for energy savings that result from product design changes are also taken from the TSD. The two main environmental concerns addressed are emissions from fossil fuel-fired electricity generation and the chlorofluorcarbons used in the production of rigid insulation foam. Each of the 12 design options for refrigerators and freezers result in decreased electricity use and and, therefore, reduced power plant emissions. Design changes that call for additional rigid foam insulation per appliance are of interest because they affect chlorofluorocarbon consumption. There is strong evidence that chlorofluorocarbons migrate to the stratosphere, break down, and catalyze the destruction of stratospheric ozone.

Not Available

1988-01-01T23:59:59.000Z

58

Refrigerant charge management in a heat pump water heater  

DOE Patents [OSTI]

Heat pumps that heat or cool a space and that also heat water, refrigerant management systems for such heat pumps, methods of managing refrigerant charge, and methods for heating and cooling a space and heating water. Various embodiments deliver refrigerant gas to a heat exchanger that is not needed for transferring heat, drive liquid refrigerant out of that heat exchanger, isolate that heat exchanger against additional refrigerant flowing into it, and operate the heat pump while the heat exchanger is isolated. The heat exchanger can be isolated by closing an electronic expansion valve, actuating a refrigerant management valve, or both. Refrigerant charge can be controlled or adjusted by controlling how much liquid refrigerant is driven from the heat exchanger, by letting refrigerant back into the heat exchanger, or both. Heat pumps can be operated in different modes of operation, and segments of refrigerant conduit can be interconnected with various components.

Chen, Jie; Hampton, Justin W.

2014-06-24T23:59:59.000Z

59

China Refrigerator Information Label: Specification Development and Potential Impact  

E-Print Network [OSTI]

years. About 20% of refrigerators and freezers sold in 2000energy efficiency of refrigerators and freezers, Directiveof Energy, for refrigerators and freezers are base unit

Fridley, David

2008-01-01T23:59:59.000Z

60

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys  

E-Print Network [OSTI]

vapor compression refrigerators and freezers), along withthe number of refrigerators and freezers in a home alongcompression refrigerators and freezers) in U.S. households.

Greenblatt, Jeffery B.

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Development of a high-efficiency, automatic-defrosting refrigerator-freezer. Phase II. Field test. Volume III. Executive summary and task reports  

SciTech Connect (OSTI)

The second phase of the development of a high-efficiency, automatic-defrosting, refrigerator-freezer is described. Following the successful completion of Phase I (design, construction, and laboratory testing of a 16 ft/sup 3/ high efficiency refrigerator-freezer prototype), Phase II was initiated to evaluate sales potential and in-home performance as a necessary step in creating a product that was both manufacturable and marketable. Twenty-five pilot production 18 ft/sup 3/ units using prototype tooling were produced on the assembly line to confirm the feasibility of full-scale production. These units were then used in a market and field test program in which consumer appeal and in-home performance were assessed. The market evaluation confirmed that refrigerators incorporating high-efficiency features at added cost are saleable and that large capacity, automatic-defrosting, refrigerator-freezers will continue to capture a large portion of the market in the years ahead, The field test confirmed the in-home energy saving potential of a high efficiency, automatic-defrosting refrigerator-frezer utilizing advanced design features such as optimized, thick-wall, foam an average energy savings of 60% compared to a baseline unit of conventional design.

Topping, R.F.

1982-12-01T23:59:59.000Z

62

Using National Survey Data to Estimate Lifetimes of Residential Appliances  

E-Print Network [OSTI]

conditioners (RACs), refrigerators, and freezers. GENERALsection). Refrigerators and Freezers Refrigerators followDifference* this Study Freezer Refrigerator Water Heater,

Lutz, James D.

2013-01-01T23:59:59.000Z

63

2014-09-23 Issuance: Energy Conservation Standard for Walk-in Coolers and Freezers; Air-Conditioning, Heating, & Refrigeration Institute Petition for Reconsideration Notice of Public Meeting  

Broader source: Energy.gov [DOE]

This document is a pre-publication Federal Register notice of public meeting regarding energy conservation standards for walk-in coolers and freezers; Air-Conditioning, Heating, & Refrigeration Institute petition for reconsideration, as issued by the Deputy Assistant Secretary for Energy Efficiency on September 23, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

64

Small Commercial Refrigeration Incentive | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Small Commercial Refrigeration Incentive Small Commercial Refrigeration Incentive Small Commercial Refrigeration Incentive < Back Eligibility Agricultural Commercial Industrial Institutional Nonprofit Savings Category Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Incentives over $5,000 must be pre-approved Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Outside Air Economizers: $1,250 Evaporator Fan Motors: $20 - $100 Evaporator Fan Motor Controls: $550 Door/Frame Heater Controls: $50 per door Case Light Occupancy Controls: $40 LED Refrigerator and Freezer Case Light Fixtures: $6 - $15 per foot Energy Star Ice Machines: $50 - $75 Efficient Compressors: $200 Display Case Strip-Curtain and Continuous Covers: $6 per foot

65

White Paper on Energy Efficiency Status of Energy-Using Products in China (2011)  

E-Print Network [OSTI]

Variable speed AC Gas water heaters Refrigerators Freezer-refrigerators Freezers CC?4500 CC?7100 CC?14000 CC?4500 CC?televisions, refrigerators (with freezer), cellular phones,

Zhou, Nan

2013-01-01T23:59:59.000Z

66

Prioritizing Climate Change Mitigation Alternatives: Comparing Transportation Technologies to Options in Other Sectors  

E-Print Network [OSTI]

heaters Walk-in refrigerators and freezers Single-voltagewashers, commercial refrigerators and freezers, commercialDay Domestic Refrigerator – Freezer. ” ASHRAE Transactions ,

Lutsey, Nicholas P.

2008-01-01T23:59:59.000Z

67

DOE/EA-1643: Finding of No Significant Impact for 10 CFR Part 431 Commerical Refrigeration Equipment (12/31/08)  

Broader source: Energy.gov (indexed) [DOE]

FINDING OF NO SIGNIFICANT IMPACT FOR FINDING OF NO SIGNIFICANT IMPACT FOR 10 CFR Part 431 Energy Conservation Program for Commercial and Industrial Equipment: Energy Conservation Standards for Commercial Ice-Cream Freezers; Self-Contained Commercial Refrigerators, Commercial Freezers, and Commercial Refrigerator- Freezers without Doors; and Remote Condensing Commercial Refrigerators, Commercial Freezers, and Commercial Refrigerator-Freezers December 31, 2008 [6450-01-P] DEPARTMENT OF ENERGY 10 CFR Part 431 [Docket Number: EERE-2006-STD-OI26] RIN 1904-AB59 Energy Conservation Program for Commercial and Industrial Equipment: Energy Conservation Standards for Commercial Ice-Cream Freezers; Self-Contained Commercial Refrigerators, Commercial Freezers, and Commercial Refrigerator- . Freezers without

68

DOE/EA-1643: Environmental Assessment for 10 CFR 431 Commercial Refrigeration Equipment (December 2008)  

Broader source: Energy.gov (indexed) [DOE]

ENVIRONMENTAL ASSESSMENT FOR ENVIRONMENTAL ASSESSMENT FOR 10 CFR Part 431 Energy Conservation Program for Commercial and Industrial Equipment: Energy Conservation Standards for Commercial Ice-Cream Freezers; Self-Contained Commercial Refrigerators, Commercial Freezers, and Commercial Refrigerator- Freezers without Doors; and Remote Condensing Commercial Refrigerators, Commercial Freezers, and Commercial Refrigerator-Freezers December 2008 CHAPTER 16. ENVIRONMENTAL IMPACT ANALYSIS TABLE OF CONTENTS 16.1 INTRODUCTION ............................................................................................................ 16-1 16.2 AIR QUALITY ANALYSIS ............................................................................................ 16-1

69

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys  

E-Print Network [OSTI]

refrigerator operate with propane as well as electricity?refrigerator operate with propane as well as electricity? [freezer operate with propane as well as electricity? [

Greenblatt, Jeffery B.

2014-01-01T23:59:59.000Z

70

Cospolich Refrigerator: Order (2013-CE-5314)  

Broader source: Energy.gov [DOE]

DOE ordered Cospolich Refrigerator Co, Inc. to pay a $8,000 civil penalty after finding Cospolich Refrigerator had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

71

Refrigerator Manufacturers: Order (2013-CE-5341)  

Broader source: Energy.gov [DOE]

DOE ordered Refrigerator Manufacturers, LLC to pay a $8,000 civil penalty after finding Refrigerator Manufacturers had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

72

Analysis of household refrigerators for different testing standards  

SciTech Connect (OSTI)

This study highlights the salient differences among various testing standards for household refrigerator-freezers and proposes a methodology for predicting the performance of a single evaporator-based vapor-compression refrigeration system (either refrigerator or freezer) from one test standard (where the test data are available-the reference case) to another (the alternative case). The standards studied during this investigation include the Australian-New Zealand Standard (ANZS), the International Standard (ISO), the American National Standard (ANSI), the Japanese Industrial Standard (JIS), and the Chinese National Standard (CNS). A simple analysis in conjunction with the BICYCLE model (Bansal and Rice 1993) is used to calculate the energy consumption of two refrigerator cabinets from the reference case to the alternative cases. The proposed analysis includes the effect of door openings (as required by the JIS) as well as defrost heaters. The analytical results are found to agree reasonably well with the experimental observations for translating energy consumption information from one standard to another.

Bansal, P.K. [Univ. of Auckland (New Zealand). Dept. of Mechanical Engineering; McGill, I. [Fischer and Paykel Ltd., Auckland (New Zealand)

1995-08-01T23:59:59.000Z

73

Refrigerator-Freezers (multiple defrost waiver) | Department...  

Energy Savers [EERE]

templates for reporting the results of tests conducted in accordance with current DOE test procedures. Templates may be used by third-party laboratories under contract with DOE...

74

ENVIRONMENTAL ASSESSMENT FOR THE PROPOSED ENERGY CONSERVATION STANDARD FOR REFRIGERATORS, REFRIGERATOR-  

Broader source: Energy.gov (indexed) [DOE]

ASSESSMENT FOR THE PROPOSED ENERGY ASSESSMENT FOR THE PROPOSED ENERGY CONSERVATION STANDARD FOR REFRIGERATORS, REFRIGERATOR- , AND FREEZERS - 1. INTRODUCTION AND NEED FOR PROPOSED ACTION ental Assessment (EA) on the candidate energy conservation stand licy Act. of 1969 (NEPA), regulations of the Council on Environmentd Qu refrigerators, re€iigerator-freezers, and freezers was prepared pursuant to the National ' ederal Regulations, Parts 1500 through. 1508. The proposed energy conservation standard (Level 1) and the alternative standards are being reviewed in an energy- efficiency standards rulemaking that the Department has undertaken pursuant to the Energy Policy and Conservation Act, as amended by the National Energy Conservation Policy Act and the National Appliance Energy Consehation Act

75

VEA-0015 - In the Matter of Sub-Zero Freezer Co. | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

5 - In the Matter of Sub-Zero Freezer Co. 5 - In the Matter of Sub-Zero Freezer Co. VEA-0015 - In the Matter of Sub-Zero Freezer Co. Sub-Zero Freezer Co. (Sub-Zero), GE Appliances (GE), and Whirlpool Corporation (Whirlpool) filed appeals of our November 3, 2000 decision, granting Viking Range Corporation (Viking) a six-month exception from the 2001 energy appliance efficiency standards for built-in refrigerators. Viking Range Corp., 28 DOE ¶ 81,002 (2000). As discussed below, we have granted the appeals in part. As a result, the six-month exception will be limited to 475 refrigerators per month and will be subject to a monthly reporting requirement. vea0015-16-17.pdf More Documents & Publications VEH-0015 - In the Matter of Sub-Zero Freezer Co. VEA-0017 - In the Matter of Whirlpool Corporation

76

Refrigerator Manufacturers: Proposed Penalty (2013-CE-5341)  

Broader source: Energy.gov [DOE]

DOE alleged in a Notice of Proposed Civil Penalty that Refrigerator Manufacturers, LLC failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards.

77

Cospolich Refrigerator: Proposed Penalty (2013-CE-5314)  

Broader source: Energy.gov [DOE]

DOE alleged in a Notice of Proposed Civil Penalty that Cospolich Refrigerator Co, Inc. failed to certify walk-in cooler or freezer components as compliant with the energy conservation standards.

78

Hydrophilic structures for condensation management in refrigerator appliances  

DOE Patents [OSTI]

A refrigerator appliance that includes a freezer compartment having a freezer compartment door, and a refrigeration compartment having at least one refrigeration compartment door. The appliance further includes a mullion with an exterior surface. The mullion divides the compartments and the exterior surface directs condensation toward a transfer point. The appliance may also include a cabinet that houses the compartments and has two sides, each with an exterior surface. Further, at least one exterior surface directs condensation toward a transfer point.

Kuehl, Steven John; Vonderhaar, John J; Wu, Guolian; Wu, Mianxue

2014-10-21T23:59:59.000Z

79

Catalog of DC Appliances and Power Systems  

E-Print Network [OSTI]

current residential refrigerators and freezers rulemaking,Refrigerator/Freezers. .Refrigerator, Refrigerator-Freezer, and Freezers Rulemaking,

Garbesi, Karina

2012-01-01T23:59:59.000Z

80

Duracold Refrigeration Manufacturing: Order (2013-CE-5342) | Department of  

Broader source: Energy.gov (indexed) [DOE]

Duracold Refrigeration Manufacturing: Order (2013-CE-5342) Duracold Refrigeration Manufacturing: Order (2013-CE-5342) Duracold Refrigeration Manufacturing: Order (2013-CE-5342) April 25, 2013 DOE ordered Duracold Refrigeration Manufacturing Company, LLC to pay a $8,000 civil penalty after finding Duracold Refrigeration Manufacturing had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards. The Order adopted a Compromise Agreement, which reflected settlement terms between DOE and Duracold Refrigeration Manufacturing. Duracold Refrigeration Manufacturing: Order (2013-CE-5342) More Documents & Publications Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) North Star Refrigerator: Order (2013-CE-5355) Schott Gemtron: Order (2013-CE-5358

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Refrigerators and Refrigerator-Freezers (Appendix A1 after May...  

Energy Savers [EERE]

templates for reporting the results of tests conducted in accordance with current DOE test procedures. Templates may be used by third-party laboratories under contract with DOE...

82

North Star Refrigerator: Order (2013-CE-5355)  

Broader source: Energy.gov [DOE]

DOE ordered North Star Refrigerator Co., Inc. to pay a $8,000 civil penalty after finding North Star Refrigerator had failed to certify that any basic models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

83

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 through 2012  

E-Print Network [OSTI]

Refrigerator-Freezers .Refrigerators and Refrigerator-Freezers NAECA 1987 Freezers2005 Refrigerators, Refrigerator-Freezers and Freezers 2010,

Meyers, Stephen

2013-01-01T23:59:59.000Z

84

VEH-0015 - In the Matter of Sub-Zero Freezer Co. | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

VEH-0015 - In the Matter of Sub-Zero Freezer Co. VEH-0015 - In the Matter of Sub-Zero Freezer Co. VEH-0015 - In the Matter of Sub-Zero Freezer Co. Motion for Evidentiary Hearing Sub-Zero Freezer Co. (Sub-Zero) filed a motion for evidentiary hearing with the Office of Hearings and Appeals (OHA) of the Department of Energy (DOE). The motion relates to Sub-Zero's appeal (Case No. VEA-0015) of our November 3 decision, in which we granted Viking Range Corporation (Viking) a six-month exception from the 2001 energy appliance efficiency standards for built-in refrigerators. Viking Range Corporation, 28 DOE ¶ 81,002 (2000). As discussed below, we have concluded that the motion should be granted in part. veh0015.pdf More Documents & Publications VEA-0015 - In the Matter of Sub-Zero Freezer Co. VEA-0016 - In the Matter of GE Appliances

85

DOE Opens Three Investigations into Alleged Refrigerator Efficiency  

Broader source: Energy.gov (indexed) [DOE]

Opens Three Investigations into Alleged Refrigerator Efficiency Opens Three Investigations into Alleged Refrigerator Efficiency Violations DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations April 12, 2010 - 7:27pm Addthis The Department of Energy has issued one subpoena and two data requests to three companies in response to allegations that the companies are selling refrigerator-freezers that failed to meet federal energy efficiency standards. Under the subpoena, Arçelik A.S, a Turkish Company is required to submit detailed information about the design, marketing and U.S. sales of its Blomberg brand refrigerator-freezer, model "BRFB1450." The Department also requested testing data from Whirlpool Corporation and Viking Range Corporation for two refrigerator-freezers that the companies

86

DOE Opens Three Investigations into Alleged Refrigerator Efficiency  

Broader source: Energy.gov (indexed) [DOE]

Opens Three Investigations into Alleged Refrigerator Efficiency Opens Three Investigations into Alleged Refrigerator Efficiency Violations DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations April 12, 2010 - 7:27pm Addthis The Department of Energy has issued one subpoena and two data requests to three companies in response to allegations that the companies are selling refrigerator-freezers that failed to meet federal energy efficiency standards. Under the subpoena, Arçelik A.S, a Turkish Company is required to submit detailed information about the design, marketing and U.S. sales of its Blomberg brand refrigerator-freezer, model "BRFB1450." The Department also requested testing data from Whirlpool Corporation and Viking Range Corporation for two refrigerator-freezers that the companies

87

Energy Consumption of Refrigerators in Ghana - Outcomes of Household  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Energy Consumption of Refrigerators in Ghana - Outcomes of Household Energy Consumption of Refrigerators in Ghana - Outcomes of Household Surveys Speaker(s): Essel Ben Hagan Date: July 12, 2007 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Robert Van Buskirk Galen Barbose As part of activities to develop refrigerator efficiency standards regulations in Ghana, a national survey on the energy consumption of refrigerators and refrigerator-freezers has been conducted. The survey covered 1000 households in urban, peri-urban and rural communities in various parts of the country. The survey found that, on average, refrigerators and refrigerator-freezers in Ghana use almost three times what is allowed by minimum efficiency standards in the U.S., and a few refrigerators had energy use at levels almost ten times the U.S.

88

Carbon Dioxide Heat Pump Water Heater Research Project | Department of  

Broader source: Energy.gov (indexed) [DOE]

Emerging Technologies » Carbon Dioxide Heat Pump Water Heater Emerging Technologies » Carbon Dioxide Heat Pump Water Heater Research Project Carbon Dioxide Heat Pump Water Heater Research Project The U.S. Department of Energy is currently conducting research into carbon dioxide (CO2) heat pump water heaters. This project will employ innovative techniques to adapt water heating technology to meet U.S. market requirements, including specifications, cost, and performance targets. Carbon dioxide is a refrigerant with a global warming potential (GWP) of 1. The CO2 heat pump water heater research seeks to develop an improved life cycle climate performance compared to conventional refrigerants. For example, R134a, another type of refrigerant, has a GWP of 1,300. Project Description This project seeks to develop a CO2-based heat pump water heater (HPWH)

89

DOE Closes Investigation of Arcelik's Blomberg Refrigerator | Department of  

Broader source: Energy.gov (indexed) [DOE]

Arcelik's Blomberg Refrigerator Arcelik's Blomberg Refrigerator DOE Closes Investigation of Arcelik's Blomberg Refrigerator September 1, 2010 - 4:37pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Arcelik's Blomberg refrigerator-freezer model # BRFB1450. The Department opened this investigation based on a complaint. DOE subpoenaed information from Arcelik, reviewed Arcelik's response, and performed its own testing of this model. Based on our investigation and test results, DOE has determined this model to be compliant with federal energy conservation standards. Notice of Compliance Determination Addthis Related Articles DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations DOE Closes Investigation of Whirlpool's Maytag Refrigerator

90

Convective heater  

DOE Patents [OSTI]

A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation.

Thorogood, Robert M. (Macungie, PA)

1983-01-01T23:59:59.000Z

91

Convective heater  

DOE Patents [OSTI]

A convective heater for heating fluids such as a coal slurry is constructed of a tube circuit arrangement which obtains an optimum temperature distribution to give a relatively constant slurry film temperature. The heater is constructed to divide the heating gas flow into two equal paths and the tube circuit for the slurry is arranged to provide a mixed flow configuration whereby the slurry passes through the two heating gas paths in successive co-current, counter-current and co-current flow relative to the heating gas flow. This arrangement permits the utilization of minimum surface area for a given maximum film temperature of the slurry consistent with the prevention of coke formation.

Thorogood, Robert M. (Macungie, PA)

1986-01-01T23:59:59.000Z

92

International Review of the Development and Implementation of Energy Efficiency Standards and Labeling Programs  

E-Print Network [OSTI]

energy labeling for refrigerators and freezers and nationalhousehold electric refrigerators, freezers and combinationfor Refrigerators, Refrigerator-Freezers and Freezers. ”

Zhou, Nan

2013-01-01T23:59:59.000Z

93

DOE Proposes Higher Efficiency Standards for Refrigerators | Department of  

Broader source: Energy.gov (indexed) [DOE]

DOE Proposes Higher Efficiency Standards for Refrigerators DOE Proposes Higher Efficiency Standards for Refrigerators DOE Proposes Higher Efficiency Standards for Refrigerators September 28, 2010 - 12:00am Addthis WASHINGTON, DC - U.S. Energy Secretary Steven Chu today announced the release of a new proposed energy efficiency standard for residential refrigerators, refrigerator-freezers, and freezers. The standard, as proposed, could save consumers as much as $18.6 billion over thirty years. The Obama Administration has made efficiency standards a major priority as a way to save energy and money for American families and businesses. Since January 2009, the Department of Energy has finalized new efficiency standards for more than twenty household and commercial products, which will cumulatively save consumers between $250 billion and

94

Refrigerator recycling and CFCs  

SciTech Connect (OSTI)

Utility-sponsored refrigerator and freezer pick-up programs have removed almost 900,000 inefficient appliances from the North American electric grid to date. While the CFC-12 refrigerant from the discarded appliances is typically removed and recycled, in all but a few programs the CFC-11 in the foam insulation is not. About a quarter-billion pounds of CFC-11 are banked in refrigerator foam in the United States. Release of this ``bank`` of CFC, combined with that from foam insulation used in buildings, will be the largest source of future emissions if preventive measures are not taken. Methods exist to recover the CFC for reuse or to destroy it by incineration. The task of recycling or destroying the CFCs and other materials from millions of refrigerators is a daunting challenge, but one in which utilities can play a leadership role. E Source believes that utilities can profitably serve as the catalyst for public-private partnerships that deliver comprehensive refrigerator recycling. Rather than treating such efforts solely as a DSM resource acquisition, utilities could position these programs as a multifaceted service delivery that offers convenient appliance removal for homeowners, a solid waste minimization service for landfills, a source of recycled materials for industry, and a CFC recovery and/or disposal service in support of the HVAC industry and society`s atmospheric protection goals and laws. Financial mechanisms could be developed through these public-private enterprises to ensure that utilities are compensated for the extra cost of fully recycling refrigerators, including the foam CFC.

Shepard, M.; Hawthorne, W.; Wilson, A.

1994-12-31T23:59:59.000Z

95

Loveland Water and Power - Refrigerator Recycling Program | Department of  

Broader source: Energy.gov (indexed) [DOE]

Refrigerator Recycling Program Refrigerator Recycling Program Loveland Water and Power - Refrigerator Recycling Program < Back Eligibility Residential Savings Category Appliances & Electronics Maximum Rebate Limit one rebate per account per year Program Info State Colorado Program Type Utility Rebate Program Rebate Amount Refrigerator and Freezer Recycling: $35 Loveland Water and Power is providing an incentive for its customers to recycle their old refrigerators. Interested customers can call the utility to arrange a time to pick up the old refrigerator. The old refrigerator should be brought outside but remain plugged in so the utility can make it is in working condition. the utility will then take the refrigerator to a recycling facility and issue a $35 bill credit. Other Information

96

Application of Best Industry Practices to the Design of Commercial Refrigerators  

SciTech Connect (OSTI)

The substantial efficiency improvements which have been realized in residential refrigerators over the last twenty years due to implementation of the National Appliance Energy Conservation Act and changing consumer reactions to energy savings give an indication of the potential for improvement in the commercial sector, where few such efficiency improvements have been made to date. The purchase decision for commercial refrigerators is still focused primarily on first cost and product performance issues such as maximizing storage capacity, quick pulldown, durability, and reliability. The project applied techniques used extensively to reduce energy use in residential refrigeration to a commercial reach-in refrigerator. The results will also be applicable to other commercial refrigeration equipment, such as refrigerated vending machines, reach-in freezers, beverage merchandisers, etc. The project described in this paper was a collaboration involving the Appliance and Building Technology Sector of TIAX, the Delfield Company, and the U. S. Department of Energy's Office of Building Technologies. Funding was provided by DOE through Cooperative Agreement No. DE-FC26-00NT41000. The program plan and schedule were structured to assure successful integration of the TIAX work on development of efficient design concepts into Delfield's simultaneous development of the Vantage product line. The energy-saving design options evaluated as part of the development included brushless DC and PSC fan motors, high-efficiency compressors, variable-speed compressor technology, cabinet thermal improvement (particularly in the face frame area), increased insulation thickness, a trap for the condensate line, improved insulation, reduced-wattage antisweat heaters, non-electric antisweat heating, off-cycle defrost termination, rifled heat exchanger tubing, and system optimization (selection of heat exchangers, fans, and subcooling, superheat, and suction temperatures for efficient operation). The project started with a thorough evaluation of the baseline Delfield Model 6051 two-door reach-in refrigerator. Performance testing was done to establish a performance baseline which, to meet end-users requirements, would have to be met or exceeded by the high-efficiency refrigerator design. Energy testing was done to establish the baseline energy use. Diagnostic testing such as reverse heat leak testing and insulation conductivity testing was done to evaluate factors contributing to the cabinet load and energy use. Modeling was done to assess the energy savings potential of the energy saving design options. Discussion with vendors and cost modeling was done to assess the manufacturing cost impact of the options. Based on this work, the following group of design options was selected for incorporation in the final refrigerator design: (1) Brushless DC evaporator fans; (2) Improved face frame design; (3) Reduced antisweat heater wattage; (4) Condensate line trap; and (5) Optimized refrigeration system. There was no net cost premium associated with these design changes, leading to a high-efficiency design requiring no payback of any initial additional investment. Delfield incorporated these design options in the Vantage line design and built a first prototype, which was tested at TIAX. Additional design changes were implemented in the transition to manufacturing, based in part on results of initial prototype testing, and a pilot production unit was sent to TIAX for final testing. The energy use of the pilot production unit was 68% less than that of the baseline refrigerator when tested according to the ASHRAE 117 Energy Test Standard. The energy test results for the baseline refrigerator and the two new-design units is shown in Figure ES-1 below. The resulting energy consumption is well below Energy Star and proposed Canadian and California standards levels. Delfield has successfully transitioned the design to production and is manufacturing all configurations of the energy efficient reach-ins at a rate greater than 7,000 per year, with production quantities projec

None

2002-06-30T23:59:59.000Z

97

Ex Parte Communication_Kitable Refrigerator/Freezer Guidance  

Broader source: Energy.gov [DOE]

This memo memorializes the meeting between AHAM and the Department of Energy on September 25, for inclusion in the public docket. In summary, we discussed the need for DOE guidance regarding the...

98

The application of Stirling cooler to refrigeration  

SciTech Connect (OSTI)

The application field of the free-piston Stirling Cooler, Model 100A of Global Cooling BV in the refrigeration has been studied. The cooling effectiveness of the free-piston Stirling Cooler which means small capacity with better efficiency, large range of temperature and capacity modulated operation is of much use to cool a space insulated well. One practicable application is suggested here, in which FPSC and secondary heat transfer fluid are used to the single temperature refrigerator (60 liter) instead of conventional vapor compression machines. In the freezer operation at {minus}20 C inside cabinet, the steady-state test results show 25% improvement in energy consumption over original one. The application of free-piston Stirling Cooler to a freezer at lower temperature shows great potentials also.

Kim, S.Y.; Chung, W.S.; Shin, D.K.; Cho, K.S. [LG Electronics Inc., Seoul (Korea, Republic of). Living System Lab.

1997-12-31T23:59:59.000Z

99

Estimate of Cost-Effective Potential for Minimum Efficiency Performance Standards in 13 Major World Economies Energy Savings, Environmental and Financial Impacts  

E-Print Network [OSTI]

Fans Lighting Refrigerators and Freezers Space Heating Our2011b. Refrigerator, Refrigerator-Freezer and Freezers Final2011c. Refrigerator, Refrigerator-Freezer and Freezers Final

Letschert, Virginie E.

2013-01-01T23:59:59.000Z

100

Energy and Economic Impacts of U.S. Federal Energy and Water Conservation Standards Adopted From 1987 Through 2010  

E-Print Network [OSTI]

Refrigerators and Refrigerator-Freezers NAECA 1987 Freezers2005 Refrigerators, Refrigerator-Freezers and Freezers 2010,in this case refrigerator-freezers. The average new

Meyers, Stephen

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Potential Impact of Adopting Maximum Technologies as Minimum Efficiency Performance Standards in the U.S. Residential Sector  

E-Print Network [OSTI]

Refrigerators, Refrigerator-Freezers, Freezers PreliminaryRefrigerators, Refrigerator-Freezers, Freezers Pre-NOPRlighting, television, refrigerator-freezers, central air

Letschert, Virginie

2010-01-01T23:59:59.000Z

102

Malone cycle refrigerator development  

SciTech Connect (OSTI)

This paper describes the progress made in demonstrating a Malone Cycle Refrigerator/Freezer. The Malone cycle is similar to the Stirling cycle but uses a supercritical fluid in place of real gas. In the approach, solid-metal diaphragms are used to seal and sweep the working volumes against the high working fluid pressures required in Malone cycle machines. This feature eliminates the friction and leakage that accounted for nearly half the losses in the best piston-defined Malone cycle machines built to date. The authors successfully built a Malone cycle refrigerator that: (1) used CO{sub 2} as the working fluid, (2) operated at pressures up to 19.3 Mpa (2,800 psi), (3) achieved a cold end metal temperatures of {minus}29 C ({minus}20 F), and (4) produced over 400 Watts of cooling at near ambient temperatures. The critical diaphragm components operated flawlessly throughout characterization and performance testing, supporting the conclusion of high reliability based on analysis of fatigue date and actual strain measurements.

Shimko, M.A.; Crowley, C.J.

1999-07-01T23:59:59.000Z

103

Heat Pump Water Heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Water Heaters Showerheads Residential Weatherization Performance Tested Comfort Systems Ductless Heat Pumps New Construction Residential Marketing Toolkit Retail Sales...

104

Heat Pump Swimming Pool Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Swimming Pool Heaters Swimming Pool Heaters Heat Pump Swimming Pool Heaters May 29, 2012 - 1:49pm Addthis How a heat pump works. How a heat pump works. How They Work Heat pumps use electricity to capture heat and move it from one place to another. They don't generate heat. As the pool pump circulates the swimming pool's water, the water drawn from the pool passes through a filter and the heat pump heater. The heat pump heater has a fan that draws in the outside air and directs it over the evaporator coil. Liquid refrigerant within the evaporator coil absorbs the heat from the outside air and becomes a gas. The warm gas in the coil then passes through the compressor. The compressor increases the heat, creating a very hot gas that then passes through the condenser. The condenser transfers the heat from the hot gas to the cooler pool water circulating

105

Selecting a new water heater  

SciTech Connect (OSTI)

This fact sheet describes the types of water heaters available (storage water heaters, demand water heaters, heat pump water heaters, tankless coil and indirect water heaters, and solar water heaters). The criteria for selection are discussed. These are capacity, efficiency rating, and cost. A resource list is provided for further information.

NONE

1995-03-01T23:59:59.000Z

106

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network [OSTI]

RefrigerationRefrigerationRefrigeration coursecourse # 424503.0# 424503.0 v.v. 20122012 8. Heat pumps, heat pipes, cold thermal energy storage Ron on a vapour-compression cycle) /heat_pump.g Heat pumps make use of low- temperature (waste) heat, replacing/vcmfiles/ electricity!) for heating and air conditioning purposes Heat pumps became popular in ://www.bge.c Heat pumps

Zevenhoven, Ron

107

Dynamic simulation of a reverse Brayton refrigerator  

SciTech Connect (OSTI)

A test refrigerator based on the modified Reverse Brayton cycle has been developed in the Chinese Academy of Sciences recently. To study the behaviors of this test refrigerator, a dynamic simulation has been carried out. The numerical model comprises the typical components of the test refrigerator: compressor, valves, heat exchangers, expander and heater. This simulator is based on the oriented-object approach and each component is represented by a set of differential and algebraic equations. The control system of the test refrigerator is also simulated, which can be used to optimize the control strategies. This paper describes all the models and shows the simulation results. Comparisons between simulation results and experimental data are also presented. Experimental validation on the test refrigerator gives satisfactory results.

Peng, N.; Xiong, L. Y.; Dong, B.; Liu, L. Q. [State Key Laboratory of Technologies in Space Cryogenic Propellants, Technical Institute of Physics and Chemistry, CAS, Beijing, 100190 (China); Lei, L. L.; Tang, J. C. [State Key Laboratory of Technologies in Space Cryogenic Propellants, Technical Institute of Physics and Chemistry, CAS, Beijing, 100190 China and Graduate University of Chinese Academy of Sciences, Beijing, 100190 (China)

2014-01-29T23:59:59.000Z

108

Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in the United States  

E-Print Network [OSTI]

Taken together, refrigerators and freezers account for 8.9%Freezers   Refrigerator and Freezer Cases  without Doors Refrigerator, Refrigerator-Freezer and Freezers Rulemaking

Bojda, Nicholas

2011-01-01T23:59:59.000Z

109

DSM Electricity Savings Potential in the Buildings Sector in APP Countries  

E-Print Network [OSTI]

Programs Equipment Refrigerators and Freezers Mains Pressureclothes washers, refrigerators and freezers, fluorescentYear Updated Refrigerators Freezers Kimchi Refrigerators Air

McNeil, MIchael

2011-01-01T23:59:59.000Z

110

Chemical Hygiene Plan UNIVERSITY OF CALIFORNIA, IRVINE  

E-Print Network [OSTI]

.9.4 Refrigerators and Freezers 9.9.5 Portable Heaters 9.9.6 Static Electricity 9.9.7 Fuse and Overload Protection 9

Burke, Peter

111

Refrigerators and Refrigerator-Freezers (Appendix A1 after May 2, 2011)  

Broader source: Energy.gov [DOE]

The Department of Energy (DOE) develops standardized data templates for reporting the results of tests conducted in accordance with current DOE test procedures. Templates may be used by third-party laboratories under contract with DOE that conduct testing in support of ENERGY STAR® verification, DOE rulemakings, and enforcement of the federal energy conservation standards.

112

Swimming Pool Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Energy Efficiency Homes Water Heating Swimming Pool Heaters Swimming Pool Heaters July 10, 2014 Gas Swimming Pool Heaters Selecting the right kind of swimming pool heater...

113

North Star Refrigerator: Proposed Penalty (2013-CE-5355) | Department of  

Broader source: Energy.gov (indexed) [DOE]

North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) March 26, 2013 DOE alleged in a Notice of Proposed Civil Penalty that North Star Refrigerator Co., Inc. failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. North Star Refrigerator: Proposed Penalty (2013-CE-5355) More Documents & Publications

114

DOE Closes Investigation of Whirlpool's Maytag Refrigerator | Department of  

Broader source: Energy.gov (indexed) [DOE]

of Whirlpool's Maytag Refrigerator of Whirlpool's Maytag Refrigerator DOE Closes Investigation of Whirlpool's Maytag Refrigerator July 8, 2010 - 3:12pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Whirlpool's Maytag refrigerator-freezer model "MSD2578VE." The Department opened this investigation and requested testing data from Whirlpool based on a complaint (April 12, 2010, "DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations"). After reviewing the data and testing this model, the Department has found the model to be compliant with the applicable efficiency standards and has closed the investigation. The Department takes credible allegations seriously and will continue to initiate investigations on products that are

115

Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) |  

Broader source: Energy.gov (indexed) [DOE]

Duracold Refrigeration Manufacturing: Proposed Penalty Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) February 21, 2013 DOE alleged in a Notice of Proposed Civil Penalty that Duracold Refrigeration Manufacturing Company, LLC failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342)

116

DOE Closes Investigation of Whirlpool's Maytag Refrigerator | Department of  

Broader source: Energy.gov (indexed) [DOE]

Closes Investigation of Whirlpool's Maytag Refrigerator Closes Investigation of Whirlpool's Maytag Refrigerator DOE Closes Investigation of Whirlpool's Maytag Refrigerator July 8, 2010 - 3:12pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Whirlpool's Maytag refrigerator-freezer model "MSD2578VE." The Department opened this investigation and requested testing data from Whirlpool based on a complaint (April 12, 2010, "DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations"). After reviewing the data and testing this model, the Department has found the model to be compliant with the applicable efficiency standards and has closed the investigation. The Department takes credible allegations seriously and will continue to initiate investigations on products that are

117

North Star Refrigerator: Proposed Penalty (2013-CE-5355) | Department of  

Broader source: Energy.gov (indexed) [DOE]

North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) March 26, 2013 DOE alleged in a Notice of Proposed Civil Penalty that North Star Refrigerator Co., Inc. failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. North Star Refrigerator: Proposed Penalty (2013-CE-5355) More Documents & Publications

118

Grouped exposed metal heaters  

DOE Patents [OSTI]

A system for treating a hydrocarbon containing formation is described. The system includes two or more groups of elongated heaters. The group includes two or more heaters placed in two or more openings in the formation. The heaters in the group are electrically coupled below the surface of the formation. The openings include at least partially uncased wellbores in a hydrocarbon layer of the formation. The groups are electrically configured such that current flow through the formation between at least two groups is inhibited. The heaters are configured to provide heat to the formation.

Vinegar, Harold J. (Bellaire, TX); Coit, William George (Bellaire, TX); Griffin, Peter Terry (Brixham, GB); Hamilton, Paul Taylor (Houston, TX); Hsu, Chia-Fu (Granada Hills, CA); Mason, Stanley Leroy (Allen, TX); Samuel, Allan James (Kular Lumpar, MY); Watkins, Ronnie Wade (Cypress, TX)

2010-11-09T23:59:59.000Z

119

Global warming impacts of ozone-safe refrigerants and refrigeration, heating, and air-conditioning technologies  

SciTech Connect (OSTI)

International agreements mandate the phase-out of many chlorine containing compounds that are used as the working fluid in refrigeration, air-conditioning, and heating equipment. Many of the chemical compounds that have been proposed, and are being used in place of the class of refrigerants eliminated by the Montreal Protocol are now being questioned because of their possible contributions to global warming. Natural refrigerants are put forth as inherently superior to manufactured refrigerants because they have very low or zero global warming potentials (GWPs). Questions are being raised about whether or not these manufactured refrigerants, primarily hydrofluorocarbons (HFCs), should be regulated and perhaps phased out in much the same manner as CFCs and HCFCs. Several of the major applications of refrigerants are examined in this paper and the results of an analysis of their contributions to greenhouse warming are presented. Supermarket refrigeration is shown to be an application where alternative technologies have the potential to reduce emissions of greenhouse gases (GHG) significantly with no clear advantage to either natural or HFC refrigerants. Mixed results are presented for automobile air conditioners with opportunities to reduce GHG emissions dependent on climate and comfort criteria. GHG emissions for hermetic and factory built systems (i.e. household refrigerators/freezers, unitary equipment, chillers) are shown to be dominated by energy use with much greater potential for reduction through efficiency improvements than by selection of refrigerant. The results for refrigerators also illustrate that hydrocarbon and carbon dioxide blown foam insulation have lower overall effects on GHG emissions than HFC blown foams at the cost of increased energy use.

Fischer, S.; Sand, J.; Baxter, V.

1997-12-01T23:59:59.000Z

120

List of Water Heaters Incentives | Open Energy Information  

Open Energy Info (EERE)

Heaters Incentives Heaters Incentives Jump to: navigation, search The following contains the list of 973 Water Heaters Incentives. CSV (rows 1-500) CSV (rows 501-973) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio - Commercial New Construction Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Industrial Local Government Municipal Utility Nonprofit Schools State Government Central Air conditioners Chillers Comprehensive Measures/Whole Building Custom/Others pending approval Energy Mgmt. Systems/Building Controls Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Motors Water Heaters Commercial Cooking Equipment Commercial Refrigeration Equipment Room Air Conditioners Yes AEP Public Service Company of Oklahoma - Residential Efficiency Rebate Program (Oklahoma) Utility Rebate Program Oklahoma Residential Building Insulation

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

FS: heat pump water heaters | The Better Buildings Alliance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Food Service » Install a heat pump Food Service » Install a heat pump water heaterand reduce water heating energy up to 70% using the commercial heat pump water heater specificat Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Install a heat pump water heaterand reduce water heating energy up to 70% using the commercial heat pump water heater specification The Food Service team developed a Commercial Heat Pump Water Heater Specification that can be used to reduce water heating energy by 70%. An older, electric resistance water heater (operated in a building with a hot water demand of 500 gallons a day) can cost more than $3,500 each year

122

Helium dilution refrigeration system  

DOE Patents [OSTI]

A helium dilution refrigeration system operable over a limited time period, and recyclable for a next period of operation. The refrigeration system is compact with a self-contained pumping system and heaters for operation of the system. A mixing chamber contains .sup.3 He and .sup.4 He liquids which are precooled by a coupled container containing .sup.3 He liquid, enabling the phase separation of a .sup.3 He rich liquid phase from a dilute .sup.3 He-.sup.4 He liquid phase which leads to the final stage of a dilution cooling process for obtaining low temperatures. The mixing chamber and a still are coupled by a fluid line and are maintained at substantially the same level with the still cross sectional area being smaller than that of the mixing chamber. This configuration provides maximum cooling power and efficiency by the cooling period ending when the .sup.3 He liquid is depleted from the mixing chamber with the mixing chamber nearly empty of liquid helium, thus avoiding unnecessary and inefficient cooling of a large amount of the dilute .sup.3 He-.sup.4 He liquid phase.

Roach, Patrick R. (Darien, IL); Gray, Kenneth E. (Naperville, IL)

1988-01-01T23:59:59.000Z

123

Control of household refrigerators. Part 1: Modeling temperature control performance  

SciTech Connect (OSTI)

Commercial household refrigerators use simple, cost-effective, temperature controllers to obtain acceptable control. A manually adjusted airflow damper regulates the freezer compartment temperature while a thermostat controls operation of the compressor and evaporator fan to regulate refrigerator compartment temperature. Dual compartment temperature control can be achieved with automatic airflow dampers that function independently of the compressor and evaporator fan thermostat, resulting in improved temperature control quality and energy consumption. Under dual control, freezer temperature is controlled by the thermostat while the damper controls refrigerator temperature by regulating airflow circulation. A simulation model is presented that analyzes a household refrigerator configured with a conventional thermostat and both manual and automatic dampers. The model provides a new paradigm for investigating refrigerator systems and temperature control performance relative to the extensive verification testing that is typically done by manufacturers. The effects of each type of control and damper configuration are compared with respect to energy usage, control quality, and ambient temperature shift criteria. The results indicate that the appropriate control configuration can have significant effects and can improve plant performance.

Graviss, K.J.; Collins, R.L.

1999-07-01T23:59:59.000Z

124

Explosives tester with heater  

DOE Patents [OSTI]

An inspection tester system for testing for explosives. The tester includes a body and a swab unit adapted to be removeably connected to the body. At least one reagent holder and dispenser is operatively connected to the body. The reagent holder and dispenser contains an explosives detecting reagent and is positioned to deliver the explosives detecting reagent to the swab unit. A heater is operatively connected to the body and the swab unit is adapted to be operatively connected to the heater.

Del Eckels, Joel (Livermore, CA); Nunes, Peter J. (Danville, CA); Simpson, Randall L. (Livermore, CA); Whipple, Richard E. (Livermore, CA); Carter, J. Chance (Livermore, CA); Reynolds, John G. (San Ramon, CA)

2010-08-10T23:59:59.000Z

125

Technical support document: Energy conservation standards for consumer products: Refrigerators and furnaces including: environmental impacts regulatory impact analysis  

SciTech Connect (OSTI)

The National Appliance Energy Conversation Act (NAECA) of 1987 (P.L. 100-12) establishes energy efficiency standards for 13 types of consumer products. The legislation requires the Department of Energy (DOE) to consider new or amended standards on these and other types of products at specified times. DOE is currently selecting standards for two types of products: refrigerators, refrigerator-freezers, and freezers; and small gas furnaces. This Technical Support Document presents the methodology, data and results from the analysis of the energy and economic impacts of the proposed standards. 8 refs., 39 figs., 135 tabs.

Not Available

1989-11-01T23:59:59.000Z

126

Covered Product Category: Residential Freezers | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Covered Product Category: Residential Freezers Covered Product Category: Residential Freezers Covered Product Category: Residential Freezers October 7, 2013 - 11:18am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including residential freezers, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases

127

Calendar Year 2007 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network [OSTI]

solid door refrigerators and freezers Commercial steamthermostats 3 Refrigerators and freezers Residential clothescabinets, commercial refrigerators and freezers, commercial

Sanchez, Marla Christine

2008-01-01T23:59:59.000Z

128

Assessment of the Impacts of Standards and Labeling Programs in Mexico (four products).  

E-Print Network [OSTI]

of Household Refrigerators and Freezers Energy Efficiency offor Household Refrigerators and Freezers Official Mexicanof Household Refrigerators and Freezers). Name Publication

Sanchez, Itha; Pulido, Henry; McNeil, Michael A.; Turiel, Isaac; della Cava, Mirka

2007-01-01T23:59:59.000Z

129

An Exploration of Innovation and Energy Efficiency in an Appliance Industry  

E-Print Network [OSTI]

clothes washers; refrigerators and freezers; dishwashers;and tubes, household refrigerators and freezers, householdhousehold refrigerators and freezers, air conditioning (room

Taylor, Margaret

2013-01-01T23:59:59.000Z

130

Calendar Year 2008 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network [OSTI]

solid door refrigerators and freezers Commercial steamProfessional Displays Refrigerators and freezers ResidentialCommercial Refrigerators and Freezers • Computers •

Homan, GregoryK

2010-01-01T23:59:59.000Z

131

Analysis of Michigan's demand-side electricity resources in the residential sector: Volume 3, End-use studies: Revised final report  

SciTech Connect (OSTI)

This volume of the ''Analysis of Michigan's Demand-Side Electricity Resources in the Residential Sector'' contains end-use studies on various household appliances including: refrigerators, freezers, lighting systems, water heaters, air conditioners, space heaters, and heat pumps. (JEF)

Krause, F.; Brown, J.; Connell, D.; DuPont, P.; Greely, K.; Meal, M.; Meier, A.; Mills, E.; Nordman, B.

1988-04-01T23:59:59.000Z

132

Department of Energy - Swimming Pool Heaters  

Broader source: Energy.gov (indexed) [DOE]

736189 en Gas Swimming Pool Heaters http:energy.govenergysaverarticlesgas-swimming-pool-heaters heaters" class"title-link">

133

Trends in the cost of efficiency for appliances and consumer electronics  

E-Print Network [OSTI]

Appliance Refrigerators and Freezers Room Air ConditionersPCU3352283352285 a The refrigerator and freezer price trendRefrigerators, Refrigerator-Freezers, and Freezers (Final

Desroches, Louis-Benoit

2013-01-01T23:59:59.000Z

134

Realized and Projected Impacts of U.S. Energy Efficiency Standards for Residential and Commercial Appliances  

E-Print Network [OSTI]

Refrigerators, Refrigerator-Freezers, and Freezers,and Updates RESIDENTIAL Refrigerators Freezers Central Aira given year for refrigerators, freezers, clothes washers,

Meyers, Stephen P.

2008-01-01T23:59:59.000Z

135

Floating solar pool heater  

SciTech Connect (OSTI)

A floating solar heater for swimming pools is disclosed which includes a top cover, a vertical outer side wall with inclined inner side wall segments connected thereto, an outside rim and a bottom wall. The inner side wall segments are octagonal, coated with light reflective material, and aid in reflecting the sun's rays to heat the space inside the walls formed by the cover which dead air space also provides for floatation of the heater. The bottom wall is heated by direct sun inpingement and by the air in contact with it and is formed of a material having high heat conductivity.

McCluskey, J.E.

1981-08-18T23:59:59.000Z

136

Portable Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Portable Heaters Portable Heaters Portable Heaters November 26, 2013 - 2:41pm Addthis Portable heaters can be an efficient way to supplement inadequate heating. | Photo courtesy iStockphoto.com Portable heaters can be an efficient way to supplement inadequate heating. | Photo courtesy iStockphoto.com What does this mean for me? A portable heater is a good choice if you have a space that requires supplemental heating or is infrequently occupied. You should carefully follow all the manufacturer's installation and operation instructions. Small space heaters are typically used when the main heating system is inadequate or when central heating is too costly to install or operate. In some cases, small space heaters can be less expensive to use if you only want to heat one room or supplement inadequate heating in one room. They

137

Energy Conservation in Process Heaters  

E-Print Network [OSTI]

ENERGY CONSERVATION IN PROCESS HEATERS Roger l~. Bagge Neste Engineering Porvoo, Finland ABSTRACT OPTIMIZATION OF EMER~Y USE Energy savings in refinery and petrochemical fired heaters can basically be achieved in two ways: Thru optimization...

Bagge, R. W.

1982-01-01T23:59:59.000Z

138

Absorption Heat Pump Water Heater  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Absorption Heat Pump Water Heater Absorption Heat Pump Water Heater Kyle Gluesenkamp Building Equipment Group, ETSD gluesenkampk@ornl.gov 865-241-2952 April 3, 2013 CRADA - GE Development of High Performance Residential Gas Water Heater Image courtesy John Wilkes 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: Absorption technology could greatly boost water heater efficiency, but faces barriers of high first cost and working fluid challenges. Impact of Project: Energy factor of gas storage water

139

Absorption Heat Pump Water Heater  

Broader source: Energy.gov (indexed) [DOE]

Absorption Heat Pump Water Heater Absorption Heat Pump Water Heater Kyle Gluesenkamp Building Equipment Group, ETSD gluesenkampk@ornl.gov 865-241-2952 April 3, 2013 CRADA - GE Development of High Performance Residential Gas Water Heater Image courtesy John Wilkes 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: Absorption technology could greatly boost water heater efficiency, but faces barriers of high first cost and working fluid challenges. Impact of Project: Energy factor of gas storage water

140

Refrigerant directly cooled capacitors  

DOE Patents [OSTI]

The invention is a direct contact refrigerant cooling system using a refrigerant floating loop having a refrigerant and refrigeration devices. The cooling system has at least one hermetic container disposed in the refrigerant floating loop. The hermetic container has at least one electronic component selected from the group consisting of capacitors, power electronic switches and gating signal module. The refrigerant is in direct contact with the electronic component.

Hsu, John S. (Oak Ridge, TN); Seiber, Larry E. (Oak Ridge, TN); Marlino, Laura D. (Oak Ridge, TN); Ayers, Curtis W. (Kingston, TN)

2007-09-11T23:59:59.000Z

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Dehumidifying water heater  

SciTech Connect (OSTI)

The indoor swimming pool at the Glen Cove YMCA in Glen Cove, New York, has been selected for the dehumidification/water heating system demonstration project. This report provides the specifications for this system which includes a dehumidifier/air handler, condenser/water heater, and outdoor condenser. Current progress underway includes construction, vendor selection, and control system selection. (SM)

Stark, W.

1991-05-31T23:59:59.000Z

142

Fridge of the future: ORNL`s refrigeration R&D  

SciTech Connect (OSTI)

Fears about warming the globe may change the way foods are chilled. Concern about global warming, as expressed in the President`s Climate Change Action Plan of 1993, is the latest motivation for putting future American refrigerators and freezers on a strict energy diet. A current national goal is to design an environmentally sound refrigerator-freezer by 1998 that uses half as much energy as 1993 models. Interest in designing a more energy-efficient refrigerator is not new. It first became a goal almost 20 years ago. In the 1970`s the United States was relying on increasingly unstable supplies of imported oil for fuel, and energy prices began to rise. Utilities balked at building additional power plants because of rising costs and investment risks. As a result, a premium was placed on developing energy-efficient appliances, culminating in the passage of the National Appliance Energy Conservation Act of 1987. In the late 1980`s refrigerator design was again a target of engineers because of the need to change the refrigerant and insulation used. The reason: the Montreal Protocol called for phasing out of substances containing chlorofluorocarbons (CFCs) by the year 2000 because they were thought to be destroying the earth`s stratospheric ozone layer. Ozone shields humans from solar rays that can cause skin cancer and cataracts. Among the CFCs to be phased out are common refrigerants like R-12 and the refrigerator insulation blowing agent R-11.

Krause, C.

1995-12-31T23:59:59.000Z

143

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys  

SciTech Connect (OSTI)

Amazon Mechanical Turk was used, for the first time, to collect statistically representative survey data from U.S. households on the presence, number, type and usage of refrigerators, freezers, and various “miscellaneous” refrigeration products (wine/beverage coolers, residential icemakers and non-vapor compression refrigerators and freezers), along with household and demographic information. Such products have been poorly studied to date, with almost no information available about shipments, stocks, capacities, energy use, etc. A total of 9,981 clean survey responses were obtained from five distinct surveys deployed in 2012. General refrigeration product survey responses were weighted to demographics in the U.S. Energy Information Administration’s Residential Energy Consumption Survey 2009 dataset. Miscellaneous refrigeration product survey responses were weighted according to demographics of product ownership found in the general refrigeration product surveys. Model number matching for a portion of miscellaneous refrigeration product responses allowed validation of refrigeration product characteristics, which enabled more accurate estimates of the penetrations of these products in U.S. households. We estimated that there were 12.3±1.0 million wine/beverage coolers, 5.5(–3.5,+3.2) million residential icemakers and 4.4(–2.7,+2.3) million non-vapor compression refrigerators in U.S. households in 2012. (All numerical results are expressed with ranges indicating the 95% confidence interval.) No evidence was found for the existence of non-vapor compression freezers. Moreover, we found that 15% of wine/beverage coolers used vapor compression cooling technology, while 85% used thermoelectric cooling technology, with the vast majority of thermoelectric units having capacities of less than 30 wine bottles (approximately 3.5 cubic feet). No evidence was found for the existence of wine/beverage coolers with absorption cooling technology. Additionally, we estimated that there were 3.6±1.0 million hybrid refrigerator-wine/beverage coolers and 0.9±0.5 million hybrid freezer-wine/beverage coolers in U.S. households. We also obtained estimates of miscellaneous refrigeration product capacities, lifetimes, purchase and installation costs, repair frequencies and costs, and maintenance costs. For wine/beverage coolers, we also obtained information on the penetration of built-in units, AC/DC operating capability, the use of internal lights, and distributions of door opening frequencies. This information is essential to develop detailed estimates of national energy usage and life-cycle costs, and would be helpful in obtaining information on other plug-load appliances. Additional information not highlighted in the main report was presented in Appendices.

Greenblatt, Jeffery B.; Young, Scott J.; Yang, Hung-Chia; Long, Timothy; Beraki, Bereket; Price, Sarah K.; Pratt, Stacy; Willem, Henry; Desroches, Louis-Benoit

2013-11-14T23:59:59.000Z

144

DOE Closes Investigation into Energy Efficiency of Viking Refrigerator |  

Broader source: Energy.gov (indexed) [DOE]

Closes Investigation into Energy Efficiency of Viking Closes Investigation into Energy Efficiency of Viking Refrigerator DOE Closes Investigation into Energy Efficiency of Viking Refrigerator November 9, 2010 - 7:30pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Viking Range Corporation's refrigerator-freezer model VCSB542. The Department initiated this investigation in response to allegations that the model failed to meet federal energy efficiency standards. After reviewing data provided by Viking for this model, the Department issued a testing demand on June 16, 2010 and initially tested four units, one of which was defective and replaced by a fifth unit. The test results showed that two Viking units failed the federal energy standard for maximum energy use, while two passed. Because of the wide variation in the

145

DOE Closes Investigation into Energy Efficiency of Viking Refrigerator |  

Broader source: Energy.gov (indexed) [DOE]

into Energy Efficiency of Viking into Energy Efficiency of Viking Refrigerator DOE Closes Investigation into Energy Efficiency of Viking Refrigerator November 9, 2010 - 7:30pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Viking Range Corporation's refrigerator-freezer model VCSB542. The Department initiated this investigation in response to allegations that the model failed to meet federal energy efficiency standards. After reviewing data provided by Viking for this model, the Department issued a testing demand on June 16, 2010 and initially tested four units, one of which was defective and replaced by a fifth unit. The test results showed that two Viking units failed the federal energy standard for maximum energy use, while two passed. Because of the wide variation in the

146

Immersible solar heater for fluids  

DOE Patents [OSTI]

An immersible solar heater comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

Kronberg, James W. (Aiken, SC)

1995-01-01T23:59:59.000Z

147

Determination of properties of PVE lubricants with HFC refrigerants[PolyVinylEther  

SciTech Connect (OSTI)

Polyalkyleneglycol (PAG) and polyol ester (POE) have been developed as refrigeration lubricants, used with HFC134a. PAG is used for automotive air conditioning systems and POE is used for domestic reciprocating refrigerators and for A/C systems. Although PAG exhibits good lubricity performance, it is difficult to use for domestic reciprocating refrigerators due to its low dielectric property. POE is difficult to use for automotive A/C systems, due to hydrolysis and poor lubricity performance. Polyvinylether (PVE) can be used in place of PAG and POE with HFC refrigerants. PVE is used for A/C systems as well as refrigerator and freezer applications. PVE is an ideal lubricant for use with HFCs.

Kaneko, Masato; Sakanoue, Shuichi; Tazaki, Toshihiro; Tominaga, Shoichi; Takagi, Minoru; Goodin, M.

1999-07-01T23:59:59.000Z

148

ARTI refrigerant database  

SciTech Connect (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M.

1996-11-15T23:59:59.000Z

149

Covered Product Category: Residential Freezers | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Freezers Freezers Covered Product Category: Residential Freezers October 7, 2013 - 11:18am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including residential freezers, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

150

Initial Score: The UCSF LivingGreen Office Program seeks to recognize UCSF offices that have  

E-Print Network [OSTI]

unnecessary refrigerators, space heaters and other appliances OR replaced all refrigerators/freezers older than 7 years Age of Refrigerator: Contact livinggreen@ucsf.edu to assess your refrigerator if over 7 years old and get you involved in our refrigerator rebate program My office does not use CRT computer

Yamamoto, Keith

151

DOE/AHAM advanced refrigerator technology development project  

SciTech Connect (OSTI)

As part of the effort to improve residential energy efficiency and reduce greenhouse emissions from power plants, several design options were investigated for improving the energy efficiency of a conventionally designed domestic refrigerator-freezer. The program goal was to reduce the energy consumption of a 20-ft{sup 3} (570-L) top-mount refrigerator-freeze to 1.00 kWh/d, a 50% reduction from the 1993 National Appliance Energy Conservation Act (NAECA) standard. The options--such as improved cabinet and door insulation, a high-efficiency compressor, a low-wattage fan, a large counterflow evaporator, and adaptive defrost control--were incorporated into prototype refrigerator-freezer cabinets and refrigeration systems. The refrigerant HFC-134a was used as a replacement for CFC-12. The baseline energy performance of the production refrigerator-freezers, along with cabinet heat load and compressor calorimeter test results, were extensively documented to provide a firm basis for experimentally measured energy savings. The project consisted of three main phases: (1) an evaluation of energy-efficient design options using computer simulation models and experimental testing, (2) design and testing of an initial prototype unit, and (3) energy and economic analyses of a final prototype. The final prototype achieved an energy consumption level of 0.93 kWh/d--an improvement of 45% over the baseline unit and 54% over the 1993 NAECA standard for 20-fg{sup 3} (570-L) units. The manufacturer`s cost for those improvements was estimated at $134; assuming that cost is doubled for the consumer, it would take about 11.4 years to pay for the design changes. Since the payback period was thought to be unfeasible, a second, more cost-effective design was also tested. Its energy consumption level was 1.16 kWh/d, a 42% energy savings, at a manufacturer`s cost increase of $53. Again assuming a 100% markup, the payback for this unit would be 6.6 years.

Vineyard, E.A.; Sand, J.R.; Rice, C.K.; Linkous, R.L.; Hardin, C.V.; Bohman, R.H.

1997-03-01T23:59:59.000Z

152

Evaluation of Local Enforcement of Energy Efficiency Standards and Labeling Program in China  

E-Print Network [OSTI]

of 54 product models of refrigerators, freezers and room airfor household refrigerators/ freezers and room air

Zheng, Nina

2013-01-01T23:59:59.000Z

153

Environmental Stewardship: How Semiconductor Suppliers Help to Meet Energy-Efficiency Regulations and Voluntary Specifications in China  

E-Print Network [OSTI]

Standards Domestic refrigerators/freezers* Room airLabeling Domestic refrigerators/freezers* Room air

Aizhen, Li; Fanara, Andrew; Fridley, David; Merriman, Louise; Ju, Jeff

2008-01-01T23:59:59.000Z

154

Improving the energy efficiency of refrigerators in India  

SciTech Connect (OSTI)

Five state-of-the-art, production refrigerators from different manufacturers in India were subjected to a variety of appliance rating and performance evaluation test procedures in an engineering laboratory. Cabinet heat loss, compressor calorimeter, high-ambient pull-down, and closed-door energy consumption tests were performed on each unit to assess the current status of commercially available Indian refrigerators and refrigerator component efficiencies. Daily energy consumption tests were performed at nominal line voltages and at 85% and 115% of nominal voltage to assess the effect of grid voltage variations. These test results were also used to indicate opportunities for effective improvements in energy efficiency. A widely distributed ``generic`` computer model capable of simulating single-door refrigerators with a small interior freezer section was used to estimate cabinet heat loss rates and closed door energy consumption values from basic cabinet and refrigeration circuit inputs. This work helped verify the model`s accuracy and potential value as a tool for evaluating the energy impact of proposed design options. Significant differences ranging from 30 to 90% were seen in the measured performance criterion for these ``comparable`` refrigerators suggesting opportunities for improvements in individual product designs. Modeled cabinet heat loadings differed from experimentally extrapolated values in a range from 2--29%, and daily energy consumption values estimated by the model differed from laboratory data by as little as 3% or as much as 25%, which indicates that refinement of the model may be needed for this single-door refrigerator type. Additional comparisons of experimentally measured performance criteria such as % compressor run times and compressor cycling rates to modeled results are given. The computer model is used to evaluate the energy saving impact of several modest changes to the basic Indian refrigerator design.

Sand, J.R.; Vineyard, E.A. [Oak Ridge National Lab., TN (United States); Bohman, R.H. [Consulting Engineer, Cedar Rapids, IA (United States)

1995-04-01T23:59:59.000Z

155

Do You Have a Solar Water Heater?  

Broader source: Energy.gov [DOE]

Earlier this week, Ernie wrote about the economics of getting a solar water heater. As Ernie explained, a solar water heater is more expensive than a normal water heater, but depending on your area...

156

Immersible solar heater for fluids  

DOE Patents [OSTI]

An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater.

Hazen, T.C.; Fliermans, C.B.

1994-01-01T23:59:59.000Z

157

Immersible solar heater for fluids  

DOE Patents [OSTI]

An immersible solar heater is described comprising a light-absorbing panel attached to a frame for absorbing heat energy from the light and transferring the absorbed heat energy directly to the fluid in which the heater is immersed. The heater can be used to heat a swimming pool, for example, and is held in position and at a preselected angle by a system of floats, weights and tethers so that the panel can operate efficiently. A skid can be used in one embodiment to prevent lateral movement of the heater along the bottom of the pool. Alternative embodiments include different arrangements of the weights, floats and tethers and methods for making the heater. 11 figs.

Kronberg, J.W.

1995-07-11T23:59:59.000Z

158

Advanced Hybrid Water Heater using Electrochemical Compressor...  

Energy Savers [EERE]

Advanced Hybrid Water Heater using Electrochemical Compressor Advanced Hybrid Water Heater using Electrochemical Compressor Xergy is using its Electro Chemical Compression (ECC)...

159

Tankless Gas Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tankless Gas Water Heaters Tankless Gas Water Heaters Standardized Templates for Reporting Test Results tanklessgaswaterheaterv12.xlsx More Documents & Publications Heat Pump...

160

Storage Gas Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Storage Gas Water Heaters Storage Gas Water Heaters The Department of Energy (DOE) develops standardized data templates for reporting the results of tests conducted in accordance...

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Heat Pump Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Heat Pump Water Heaters Heat Pump Water Heaters Standardized Templates for Reporting Test Results heatpumpwaterheaterv1.7.xlsx More Documents & Publications Tankless Gas Water...

162

Save with Hybrid Refrigeration  

E-Print Network [OSTI]

SAVE WITH HYBRID REFRIGERATION Cheng-Wen (Wayne) Chung, P.E. Fluor Engineers, Inc. Irvine, California ABSTRACT Two level demand makes it possible to use two systems for refrigeration and save energy and money. An example of this type... of refrigeration, consisting of an ammonia absorption refrigeration (AAR) unit and a mechanical compression refrigera tion (MCR) unit, is presented in this article. This paper will briefly describe process configur ation, advantages and utility consumption...

Chung, C. W.

163

Refrigerants in Transition  

E-Print Network [OSTI]

component of ternary blends and as a blowing agent. Further testing is ongoing to determine its performance characteristics. Since CFC-114 chillers constitute an estimated 1% of the more than 80,000 centrifugal chillers, testing has not been a high..., commercial refrigerators, ice makers, etc. Some commercial chillers. Some commercial refrigeration. Marine refrigeration, stationery chillers, ternary blends, blowing agents. 51 RESULTS OF TESTING The testing programs undertaken by the refrigerant...

Stouppe, D. E.

164

Energy use of US residential refrigerators and freezers: function derivation based on household and climate characteristics  

E-Print Network [OSTI]

all units in our da- taset. (AHAM) (see Appendix 7-B in DOEownership provided by AHAM (2010, personal communication).in ownership provided by AHAM to weight the RECS ownership

Greenblatt, Jeffery

2013-01-01T23:59:59.000Z

165

9-056-462-00 (3557) EXPLOSION-PROOF REFRIGERATOR, FREEZER  

E-Print Network [OSTI]

AND MANUFACTURERS 15th and Bloomingdale Avenues, Melrose Park, Illinois 60160 1 (800) 323-0257 · Fax: 450-2BA 04 fiujxs'dun uaqA uLSTl XOaHO AHOSSaOOYii ©w^ osn -z ·punoj sx afianiap j j Axa^axpanmj aajoaao

Kleinfeld, David

166

Energy use of US residential refrigerators and freezers: function derivation based on household and climate characteristics  

E-Print Network [OSTI]

Residential Energy Consumption Survey (RECS), U.S. Energyod for estimating field energy consumption of US residentialconsumption survey—detailed tables. Residential Energy Con- sumption Survey (RECS), U.S.

Greenblatt, Jeffery

2013-01-01T23:59:59.000Z

167

Calendar Year 2007 Program Benefits for U.S. EPA Energy Star Labeled Products: Expanded Methodology  

E-Print Network [OSTI]

solid door refrigerator and freezer Commercial steam cooker4, 5 New home Refrigerator and freezer 6 Residential clothesdoor commercial refrigerators and freezers, refrigerated

Sanchez, Marla

2010-01-01T23:59:59.000Z

168

International Comparison of Energy Efficiency Awards for Appliance Manufacturers and Retailers  

E-Print Network [OSTI]

dehumidifiers, refrigerators and freezers, room airAutomatic Commercial Ice Makers Refrigerators, Freezers,and Refrigerator?Freezers Refrigerated Beverage Vending

Zhou, Nan

2014-01-01T23:59:59.000Z

169

Methods for forming long subsurface heaters  

DOE Patents [OSTI]

A method for forming a longitudinal subsurface heater includes longitudinally welding an electrically conductive sheath of an insulated conductor heater along at least one longitudinal strip of metal. The longitudinal strip is formed into a tubular around the insulated conductor heater with the insulated conductor heater welded along the inside surface of the tubular.

Kim, Dong Sub

2013-09-17T23:59:59.000Z

170

Heater head for stirling engine  

DOE Patents [OSTI]

A monolithic heater head assembly which augments cast fins with ceramic inserts which narrow the flow of combustion gas and obtains high thermal effectiveness with the assembly including an improved flange design which gives greater durability and reduced conduction loss.

Corey, John A. (R.D. #2, Box 101 E, North Troy, NY 12182)

1985-07-09T23:59:59.000Z

171

Monitoring refrigeration energy useage.  

SciTech Connect (OSTI)

Refrigerators use more energy than any other kitchen appliance -- an unsurprising fact considering that refrigerators operate 24 hours a day, 365 days a year to keep food at a safe temperature. In many low-income households, refrigerators eat up more than half the electricity consumed in one year. And if the refrigerator in a family's home is functioning poorly, the cost to the consumer can be enormous. Discovering whether an existing refrigerator is operating inefficiently enough to warrant replacing it is an extremely difficult task for a resident who sees only a monthly electric bill. Only by knowing the approximate usage of the existing unit can anyone tell whether it would pay to buy a new, energy-efficient refrigerator. The savings from replacing older refrigerators can be substantial, and collecting the data needed to determine when refrigerators should be replaced is easier and less costly than one might think. In both Chicago and New York City, replacing existing units cut refrigerator electricity usage by more than 50%. Monitoring to develop an average usage for the existing stock of refrigerators is a task that can be completed by maintenance staff in a reasonably short time -- and identifying poorly performing units that should be immediately replaced can take just two hours of monitoring.

Cavallo, J.; Mapp, J.; Energy Systems; Wisconsin Energy Bureau

2000-05-01T23:59:59.000Z

172

ARTI refrigerant database  

SciTech Connect (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates. Citations in this report are divided into the following topics: thermophysical properties; materials compatibility; lubricants and tribology; application data; safety; test and analysis methods; impacts; regulatory actions; substitute refrigerants; identification; absorption and adsorption; research programs; and miscellaneous documents. Information is also presented on ordering instructions for the computerized version.

Calm, J.M. [Calm (James M.), Great Falls, VA (United States)] [Calm (James M.), Great Falls, VA (United States)

1996-04-15T23:59:59.000Z

173

Active magnetic refrigerants based on Gd-Si-Ge material and refrigeration apparatus and process  

DOE Patents [OSTI]

Active magnetic regenerator and method using Gd.sub.5 (Si.sub.x Ge.sub.1-x).sub.4, where x is equal to or less than 0.5, as a magnetic refrigerant that exhibits a reversible ferromagnetic/antiferromagnetic or ferromagnetic-II/ferromagnetic-I first order phase transition and extraordinary magneto-thermal properties, such as a giant magnetocaloric effect, that renders the refrigerant more efficient and useful than existing magnetic refrigerants for commercialization of magnetic regenerators. The reversible first order phase transition is tunable from approximately 30 K to approximately 290 K (near room temperature) and above by compositional adjustments. The active magnetic regenerator and method can function for refrigerating, air conditioning, and liquefying low temperature cryogens with significantly improved efficiency and operating temperature range from approximately 10 K to 300 K and above. Also an active magnetic regenerator and method using Gd.sub.5 (Si.sub.x Ge.sub.1-x).sub.4, where x is equal to or greater than 0.5, as a magnetic heater/refrigerant that exhibits a reversible ferromagnetic/paramagnetic second order phase transition with large magneto-thermal properties, such as a large magnetocaloric effect that permits the commercialization of a magnetic heat pump and/or refrigerant. This second order phase transition is tunable from approximately 280 K (near room temperature) to approximately 350 K by composition adjustments. The active magnetic regenerator and method can function for low level heating for climate control for buildings, homes and automobile, and chemical processing.

Gschneidner, Jr., Karl A. (Ames, IA); Pecharsky, Vitalij K. (Ames, IA)

1998-04-28T23:59:59.000Z

174

Active magnetic refrigerants based on Gd-Si-Ge material and refrigeration apparatus and process  

DOE Patents [OSTI]

Active magnetic regenerator and method using Gd{sub 5} (Si{sub x}Ge{sub 1{minus}x}){sub 4}, where x is equal to or less than 0.5, as a magnetic refrigerant that exhibits a reversible ferromagnetic/antiferromagnetic or ferromagnetic-II/ferromagnetic-I first order phase transition and extraordinary magneto-thermal properties, such as a giant magnetocaloric effect, that renders the refrigerant more efficient and useful than existing magnetic refrigerants for commercialization of magnetic regenerators. The reversible first order phase transition is tunable from approximately 30 K to approximately 290 K (near room temperature) and above by compositional adjustments. The active magnetic regenerator and method can function for refrigerating, air conditioning, and liquefying low temperature cryogens with significantly improved efficiency and operating temperature range from approximately 10 K to 300 K and above. Also an active magnetic regenerator and method using Gd{sub 5} (Si{sub x} Ge{sub 1{minus}x}){sub 4}, where x is equal to or greater than 0.5, as a magnetic heater/refrigerant that exhibits a reversible ferromagnetic/paramagnetic second order phase transition with large magneto-thermal properties, such as a large magnetocaloric effect that permits the commercialization of a magnetic heat pump and/or refrigerant. This second order phase transition is tunable from approximately 280 K (near room temperature) to approximately 350 K by composition adjustments. The active magnetic regenerator and method can function for low level heating for climate control for buildings, homes and automobile, and chemical processing. 27 figs.

Gschneidner, K.A. Jr.; Pecharsky, V.K.

1998-04-28T23:59:59.000Z

175

Manufacture of refrigeration oils  

SciTech Connect (OSTI)

Lubricating oils suitable for use in refrigeration equipment in admixture with fluorinated hydrocarbon refrigerants are produced by solvent extraction of naphthenic lubricating oil base stocks, cooling the resulting extract mixture, optionally with the addition of a solvent modifier, to form a secondary raffinate and a secondary extract, and recovering a dewaxed oil fraction of lowered pour point from the secondary raffinate as a refrigeration oil product. The process of the invention obviates the need for a separate dewaxing operation, such as dewaxing with urea, as conventionally employed for the production of refrigeration oils.

Chesluk, R.P.; Platte, H.J.; Sequeira, A.J.

1981-12-08T23:59:59.000Z

176

Chemically assisted mechanical refrigeration process  

DOE Patents [OSTI]

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator. 5 figs.

Vobach, A.R.

1987-11-24T23:59:59.000Z

177

Chemically assisted mechanical refrigeration process  

DOE Patents [OSTI]

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator. 5 figs.

Vobach, A.R.

1987-06-23T23:59:59.000Z

178

Heat Pump Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Water Heaters Water Heaters Heat Pump Water Heaters May 4, 2012 - 5:21pm Addthis A diagram of a heat pump water heater. A diagram of a heat pump water heater. What does this mean for me? Heat pump water heaters can be two to three times more energy efficient than conventional electric storage water heaters. Heat pump water heaters work in locations that remain in the 40º-90ºF range year-round. Most homeowners who have heat pumps use them to heat and cool their homes. But a heat pump also can be used to heat water -- either as stand-alone water heating system, or as combination water heating and space conditioning system. How They Work Heat pump water heaters use electricity to move heat from one place to another instead of generating heat directly. Therefore, they can be two to

179

Small Space Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Small Space Heater Basics Small Space Heater Basics Small Space Heater Basics August 19, 2013 - 10:38am Addthis Small space heaters, also called portable heaters, are typically used when the main heating system is inadequate or when central heating is too costly to install or operate. Space heater capacities generally range between 10,000 Btu to 40,000 Btu per hour. Common fuels used for this purpose are electricity, propane, natural gas, and kerosene. Although most space heaters rely on convection (the circulation of air in a room), some rely on radiant heating; that is, they emit infrared radiation that directly heats up objects and people that are within their line of sight. Combustion Space Heaters Space heaters are classified as vented and unvented, or "vent free." Unvented combustion units are not recommended for inside use, as they

180

NEXT GENERATION COMMERCIAL HEAT PUMPWATER HEATER USING CARBON DIOXIDE USING DIFFERENT IMPROVEMENT APPROACHES  

SciTech Connect (OSTI)

Although heat pump water heaters are today widely accepted in Japan, where energy costs are high and government incentives for their use exist, acceptance of such a product in the U.S. has been slow. This trend is slowly changing with the introduction of heat pump water heaters into the residential market, but remains in the commercial sector. Barriers to heat pump water heater acceptance in the commercial market have historically been performance, reliability and first/operating costs. The use of carbon dioxide (R744) as the refrigerant in such a system can improve performance for relatively small increase in initial cost and make this technology more appealing. What makes R744 an excellent candidate for use in heat pump water heaters is not only the wide range of ambient temperatures within which it can operate, but also the excellent ability to match water to refrigerant temperatures on the high side, resulting in very high exit water temperatures of up to 82�ºC, as required by sanitary codes in the U.S. (Food Code, 2005), in a single pass, temperatures that are much more difficult to reach with other refrigerants. This can be especially attractive in applications where this water is used for the purpose of sanitation. While reliability has also been of concern historically, dramatic improvements have been made over the last several years through research done in the automotive industry and commercialization of R744 technology in residential water heating mainly in Japan. This paper presents the performance results from the development of an R744 commercial heat pump water heater of approximately 35 kW and a comparison to a baseline R134a unit of the same capacity and footprint. In addition, recommendations are made for further improvements of the R744 system which could result in possible energy savings of up to 20 %.

Chad Bowers; Michael Petersen; Stefan Elbel; Pega Hrnjak

2012-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

VEE-0075 - In the Matter of Viking Range Corporation | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Program for Consumer Products: Energy Conservation Standards for Refrigerators, Refrigerator-Freezers and Freezers (Refrigerator Efficiency Standards). In its exception...

182

Tankless Gas Water Heater Performance - Building America Top...  

Energy Savers [EERE]

Tankless Gas Water Heater Performance - Building America Top Innovation Tankless Gas Water Heater Performance - Building America Top Innovation This photo shows a hot water heater...

183

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network [OSTI]

M.V. Lapsa. 2001. Residential Heat Pump Water Heater (HPWH)Calwell. 2005. Residential Heat Pump Water Heaters: Energyfor Residential Heat Pump Water Heaters Installed in

Franco, Victor

2011-01-01T23:59:59.000Z

184

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network [OSTI]

2001. Residential Heat Pump Water Heater (HPWH) Development2005. Residential Heat Pump Water Heaters: Energy Efficiencyfor Residential Heat Pump Water Heaters Installed in

Franco, Victor

2011-01-01T23:59:59.000Z

185

Heat pump water heater and storage tank assembly  

DOE Patents [OSTI]

A water heater and storage tank assembly comprises a housing defining a chamber, an inlet for admitting cold water to the chamber, and an outlet for permitting flow of hot water from the chamber. A compressor is mounted on the housing and is removed from the chamber. A condenser comprises a tube adapted to receive refrigerant from the compressor, and winding around the chamber to impart heat to water in the chamber. An evaporator is mounted on the housing and removed from the chamber, the evaporator being adapted to receive refrigerant from the condenser and to discharge refrigerant to conduits in communication with the compressor. An electric resistance element extends into the chamber, and a thermostat is disposed in the chamber and is operative to sense water temperature and to actuate the resistance element upon the water temperature dropping to a selected level. The assembly includes a first connection at an external end of the inlet, a second connection at an external end of the outlet, and a third connection for connecting the resistance element, compressor and evaporator to an electrical power source.

Dieckmann, John T. (Belmont, MA); Nowicki, Brian J. (Watertown, MA); Teagan, W. Peter (Acton, MA); Zogg, Robert (Belmont, MA)

1999-09-07T23:59:59.000Z

186

A performance correlation of horizontal solar heaters  

E-Print Network [OSTI]

The solar heaters are shown tn Figure VI, page 31 30 Figure VI Horizontal Solar Heaters ~GLAZING AND FRAME ~~ POLYETHYLENE HEATERS THERMAL IN S U LA T I N 8 CELLS THERMOCOUPLES HORIZONTAL TABLE TOP THERMOCOUPLES COPPER LEADS TO CONTROL... The solar heaters are shown tn Figure VI, page 31 30 Figure VI Horizontal Solar Heaters ~GLAZING AND FRAME ~~ POLYETHYLENE HEATERS THERMAL IN S U LA T I N 8 CELLS THERMOCOUPLES HORIZONTAL TABLE TOP THERMOCOUPLES COPPER LEADS TO CONTROL...

Gopffarth, Wilford Hugo

2012-06-07T23:59:59.000Z

187

Heater head for Stirling engine  

SciTech Connect (OSTI)

This patent describes a heater head for a Stirling engine comprising: a housing for enclosing the heater head with gas at a substantial elevated pressure; insulator means attached to the housing for insulating the heater head; inlet means attached to a regenerator in the housing for admission of relatively high pressure working fluid from the regenerator of a Stirling engine; a first annular heating wall in the housing attached to the inlet means for heating the working fluid; and, a second annular heating wall in the housing concentric with the first heating wall but of lesser diameters so that an annular space is formed between the first heating wall and the second heating wall for heating working fluid; and a third heating wall in the housing concentric with and smaller in diameter than the second heating wall forming the condensing area of a heat pipe between the second heating wall and the third heating wall.

White, M.A.; Emigh, S.G.

1987-06-09T23:59:59.000Z

188

Enhanced heat transfer tubes for film absorbers of absorption chiller/heater  

SciTech Connect (OSTI)

Absorption chiller/heaters using non-CFC refrigerants are attracting attention as environmentally friendly energy systems. As the refrigerant/absorbent pair, the water/lithium bromide aqueous solution pair is preferably used for most absorption chiller/heaters in Japan. Absorption chiller/heaters, mainly used as water chillers and air-conditioners, are commercially available at least for unit cooling capacities above 60 kW. In absorption chiller/heaters, the absorber must be made compact, because the absorber has the largest heat transfer area of the four primary heat exchangers in the system: the evaporator, absorber, regenerator and condenser. Although a great amount of information is available on the evaporator and condenser, the same type of information concerning the absorber is lacking. This paper introduces two kinds of double fluted tubes called Arm tubs and Floral tubes for film absorbers. Arm tubes are manufactured using a two-pass drawbench process, while Floral tubes are made using a single pass drawbench process. The experiments using a lithium bromide aqueous solution with the addition of 250 ppm n-octyl alcohol as the surfactant showed that Arm tubes and Floral tubes had about 40% higher heat transfer performance than plain tubes. Therefore, Floral tubes are expected to realize a high performance at low cost. Furthermore, the optimization of the number of grooves on the outside of the tubes is also described here.

Sasaki, Naoe; Nosetani, Tadashi [Sumitomo Light Metal Industry, Ltd., Nagoya, Aichi (Japan); Furukawa, Masahiro; Kaneko, Toshiyuki [Sanyo Electric Co., Ltd., Ora, Gunma (Japan). Commercial Air-Conditioning Div.

1995-12-31T23:59:59.000Z

189

Solar heater for swimming pools  

SciTech Connect (OSTI)

A solar heater for swimming pools is provided having one or more heating panels installable on a roof or the like and arranged to discharge into a pool equipped with an apron without need for disturbing or obstructing the apron. This is accomplished by the provision of an elevated bistable dumper adjacent the perimeter of the apron having a dispensing spout normally inclined upwardly but pivoting at intervals to discharge into the pool across the apron without obstructing it. Water to be heated is diverted from the pool filtering system to the solar heater via a pressure regulator and a solar responsive flow control.

Babcock, H.W.

1984-12-04T23:59:59.000Z

190

ARTI Refrigerant Database  

SciTech Connect (OSTI)

The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air- conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on R-32, R-123, R-124, R- 125, R-134a, R-141b, R142b, R-143a, R-152a, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses polyalkylene glycol (PAG), ester, and other lubricants. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits.

Calm, J.M.

1992-04-30T23:59:59.000Z

191

Storage Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Storage Water Heaters Storage Water Heaters Storage Water Heaters June 15, 2012 - 6:00pm Addthis Consider energy efficiency when selecting a conventional storage water heater to avoid paying more over its lifetime. | Photo courtesy of ©iStockphoto/JulNichols. Consider energy efficiency when selecting a conventional storage water heater to avoid paying more over its lifetime. | Photo courtesy of ©iStockphoto/JulNichols. Conventional storage water heaters remain the most popular type of water heating system for the home. Here you'll find basic information about how storage water heaters work; what criteria to use when selecting the right model; and some installation, maintenance, and safety tips. How They Work A single-family storage water heater offers a ready reservoir -- from 20 to

192

An internal winding high temperature heater  

Science Journals Connector (OSTI)

An internal winding high temperature heater ... General principles are outlined for the construction of compact heaters that are suitable for heating small containers or reaction vessels at constant temperature and up to about 1000 C. ...

A. J. Delbouille; E. G. Derouane

1973-01-01T23:59:59.000Z

193

Energy conversion by an electric “space heater”  

Science Journals Connector (OSTI)

By means of measuring the temperature of the air blown by an electric “space heater” one can show students that the air is heated at a rate approximately equal to the rated wattage of the heater.

Willem H. van den Berg

1998-01-01T23:59:59.000Z

194

CO2 Heat Pump Water Heater | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Heater CO2 Heat Pump Water Heater CO2 Heat Pump Water Heater Prototype
Credit: Oak Ridge National Lab CO2 Heat Pump Water Heater Prototype Credit: Oak Ridge National Lab...

195

Oil and Gas Air Heaters  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Heating technologies for energy efficiency Vol.III-1-2 Oil and Gas Air Heaters1 Guangxiao Kou Hanqing Wang Jiemin Zhou Doctoral Ph.D Ph.D Candidate Professor Professor Hunan University of Technology Hunan...

Kou, G.; Wang, H.; Zhou, J.

2006-01-01T23:59:59.000Z

196

Cryogenic optical refrigeration.  

E-Print Network [OSTI]

??This thesis compiles recent achievements in optical refrigeration, cooling a 5 wt. % ytterbium doped yttrium lithium fluoride (Yb+3:YLF) crystal through anti-Stokes fluorescence to a… (more)

Melgaard, Seth

2011-01-01T23:59:59.000Z

197

Multi-stage Cascaded Stirling Refrigerator  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Multi-stage Cascaded Stirling Refrigerator Multi-stage Cascaded Stirling Refrigerator Los Alamos National Laboratory (LANL) researchers have developed a multi-stage refrigerator,...

198

International Refrigeration: Order (2012-CE-1510) | Department...  

Broader source: Energy.gov (indexed) [DOE]

Refrigeration: Order (2012-CE-1510) July 20, 2012 DOE ordered International Refrigeration Products to pay an 8,000 civil penalty after finding International Refrigeration had...

199

Solar Swimming Pool Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Swimming Pool Heaters Swimming Pool Heaters Solar Swimming Pool Heaters May 29, 2012 - 6:03pm Addthis An example of a solar pool heater. An example of a solar pool heater. You can significantly reduce swimming pool heating costs by installing a solar pool heater. They're cost competitive with both gas and heat pump pool heaters, and they have very low annual operating costs. Actually, solar pool heating is the most cost-effective use of solar energy in many climates. How They Work Most solar pool heating systems include the following: A solar collector -- the device through which pool water is circulated to be heated by the sun A filter -- removes debris before water is pumped through the collector A pump -- circulates water through the filter and collector and back to the pool A flow control valve -- automatic or manual device that diverts pool

200

Solar Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heater Basics Solar Water Heater Basics Solar Water Heater Basics August 19, 2013 - 3:01pm Addthis Illustration of an active, closed loop solar water heater. A large, flat panel called a flat plate collector is connected to a tank called a solar storage/backup water heater by two pipes. One of these pipes runs through a cylindrical pump into the bottom of the tank, where it becomes a coil called a double-wall heat exchanger. This coil runs up through the tank and out again to the flat plate collector. Antifreeze fluid runs only through this collector loop. Two pipes run out the top of the water heater tank; one is a cold water supply into the tank, and the other sends hot water to the house. Solar water heaters use the sun's heat to provide hot water for a home or

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Solar Swimming Pool Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Swimming Pool Heaters Solar Swimming Pool Heaters Solar Swimming Pool Heaters May 29, 2012 - 6:03pm Addthis An example of a solar pool heater. An example of a solar pool heater. You can significantly reduce swimming pool heating costs by installing a solar pool heater. They're cost competitive with both gas and heat pump pool heaters, and they have very low annual operating costs. Actually, solar pool heating is the most cost-effective use of solar energy in many climates. How They Work Most solar pool heating systems include the following: A solar collector -- the device through which pool water is circulated to be heated by the sun A filter -- removes debris before water is pumped through the collector A pump -- circulates water through the filter and collector and back to the pool

202

Check-Testing of Manufacturer Self Reported Labeling Data & Compliance with MEPS  

E-Print Network [OSTI]

Table B- 1 Refrigerator and Freezer Effective capacity ?L?energy label Refrigerators and Freezers No. Product featurecon- ditioners, refrigerators and freezers, greatly improved

Zhou, Nan

2008-01-01T23:59:59.000Z

203

Calendar Year 2009 Program Benefits for ENERGY STAR Labeled Products  

E-Print Network [OSTI]

solid door refrigerators and freezers Commercial steamProfessional Displays Refrigerators and freezers ResidentialCommercial Refrigerators and Freezers • Compact Florescent

Homan, Gregory K

2011-01-01T23:59:59.000Z

204

Assessment of China's Energy-Saving and Emission-Reduction Accomplishments and Opportunities During the 11th Five Year Plan  

E-Print Network [OSTI]

televisions, refrigerators and freezers, mobile phones,dishwashers, refrigerators and freezers and clothes washersand 48 million refrigerator/freezers with exports of 20

Levine, Mark D.

2010-01-01T23:59:59.000Z

205

Energy Data Sourcebook for the U.S. Residential Sector  

E-Print Network [OSTI]

auto-defrost refrigerators and freezers, and solid-state/For example, new refrigerators and freezers have increasedfactors for refrigerators and freezers are based on data for

Wenzel, T.P.

2010-01-01T23:59:59.000Z

206

Residential Sector End-Use Forecasting with EPRI-REEPS 2.1: Summary Input Assumptions and Results  

E-Print Network [OSTI]

and the size of refrigerators and freezers; for all otherwhile water heating, refrigerator, and freezer end-uses showas projected by REEPS. Refrigerator and freezer percentage

Koomey, Jonathan G.

2010-01-01T23:59:59.000Z

207

Status of China's Energy Efficiency Standards and Labels for Appliances and International Collaboration  

E-Print Network [OSTI]

testing in 2006 for refrigerators, freezers and room air-three products (refrigerators, freezers, air-conditionersStandards Domestic refrigerators/freezers* Room air

Zhou, Nan

2010-01-01T23:59:59.000Z

208

2007 Status Report: Savings Estimates for the ENERGY STAR(R) VoluntaryLabeling Program  

E-Print Network [OSTI]

Commercial Reach-In Refrigerators and Freezers. Prepared for1996 Commercial Refrigerators and Freezers 2001 OilCommercial Reach-In Refrigerators and Freezers." March 1,

Sanchez, Marla; Webber, Carrie A.; Brown, Richard E.; Homan, Gregory K.

2007-01-01T23:59:59.000Z

209

2006 Status Report Savings Estimates for the ENERGY STAR(R) Voluntary Labeling Program  

E-Print Network [OSTI]

1996 Commercial Refrigerators and Freezers 2001 OilCommercial Reach-In Refrigerators and Freezers. Prepared forfans, and reach-in refrigerators and freezers in 2001 and

Webber, Carrie A.; Brown, Richard E.; Sanchez, Marla; Homan, Gregory K.

2006-01-01T23:59:59.000Z

210

Mitigating Carbon Emissions: the Potential of Improving Efficiency of Household Appliances in China  

E-Print Network [OSTI]

of household refrigerators and freezers 2 . Therefore, thesales of the refrigerators and freezers are about 20.6for household refrigerators and freezers has been updated

Lin, Jiang

2006-01-01T23:59:59.000Z

211

Incorporating Experience Curves in Appliance Standards Analysis  

E-Print Network [OSTI]

furnaces, and refrigerators and freezers. These allow us topumps, furnaces, refrigerators and freezers (US DepartmentPCU333415333415C Refrigerators and freezers Household

Desroches, Louis-Benoit

2012-01-01T23:59:59.000Z

212

Savings estimates for the United States Environmental Protection Agency?s ENERGY STAR voluntary product labeling program  

E-Print Network [OSTI]

cabinets commercial refrigerators and freezers commercialsolid door refrigerators and freezers Commercial steam7 New homes Refrigerators and freezers Room air conditioners

Sanchez, Marla Christine

2008-01-01T23:59:59.000Z

213

Impacts of China's Current Appliance Standards and Labeling Program to 2020  

E-Print Network [OSTI]

Standards Domestic refrigerators/freezers* Room airLabeling Domestic refrigerators/freezers* Room air3-star compartment Refrigerator/Freezer Chest frozen food

Fridley, David; Aden, Nathaniel; Zhou, Nan; Lin, Jiang

2007-01-01T23:59:59.000Z

214

Bottom-Up Energy Analysis System - Methodology and Results  

E-Print Network [OSTI]

Statement Household Refrigerators and Freezers. 2008. EC,technologies (e.g. refrigerators and freezers are groupedresidential refrigerators and freezers: function derivation

McNeil, Michael A.

2013-01-01T23:59:59.000Z

215

Compliance and Verification of Standards and Labelling Programs in China: Lessons Learned  

E-Print Network [OSTI]

for household refrigerators/ freezers and room airZhou et al 2008] Refrigerators Freezers Air conditionersZhou et al 2008] Refrigerators Freezers Air conditioners

Saheb, Yamina

2010-01-01T23:59:59.000Z

216

California DREAMing: the design of residential demand responsive technology with people in mind  

E-Print Network [OSTI]

standards on refrigerators and freezers, room and centralexample, while refrigerators and freezers contribute to peakelectric lights refrigerator/freezer plasma screen

Peffer, Therese E.

2009-01-01T23:59:59.000Z

217

Projected Regional Impacts of Appliance Efficiency Standards for the U.S. Residential Sector  

E-Print Network [OSTI]

standards Other Refrigerators and Freezers DWsandCWs: g aioo%- Other | Refrigerators and Freezers Gas and oil watermarket prices for refrigerators and freezers from 1987 to

Koomey, J.G.

2010-01-01T23:59:59.000Z

218

Energy Efficiency Standards and Labels in North America: Opportunities for Harmonization  

E-Print Network [OSTI]

States MEPS Test Procedures Refrigerators and freezersRefrigerators and freezers Split system central AC Centralof test procedures: refrigerators and freezers, room air

Wiel, Stephen

2008-01-01T23:59:59.000Z

219

U.S. residential consumer product information: Validation of methods for post-stratification weighting of Amazon Mechanical Turk surveys  

E-Print Network [OSTI]

refrigerators and freezers 4.4.3 Average numbers of refrigerators and freezers acrossthe number of refrigerators and freezers in a home along

Greenblatt, Jeffery B.

2013-01-01T23:59:59.000Z

220

Compliance and Verification of Standards and Labeling Programs in China: Lessons Learned  

E-Print Network [OSTI]

for household refrigerators/ freezers and room airZhou et al 2008] Refrigerators Freezers Air conditionersZhou et al 2008] Refrigerators Freezers Air conditioners

Saheb, Yamina

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Energy Management A Program of Energy Conservation for the Community College Facility  

E-Print Network [OSTI]

STEAM COOKERS REFRIGERATORS and FREEZERS Some importantcapability. Leveling. Refrigerators and freezers should beH Continued Refrigerators and Freezers Every food service

Authors, Various

2011-01-01T23:59:59.000Z

222

2005 Status Report Savings Estimates for the ENERGY STAR(R) Voluntary Labeling Program  

E-Print Network [OSTI]

Commercial Reach-In Refrigerators and Freezers. Prepared forCommercial Refrigerators and Freezers …… Set-topfans, and reach-in refrigerators and freezers in 2001 and

Webber, Carrie A.; Brown, Richard E.; Sanchez, Marla

2006-01-01T23:59:59.000Z

223

Welding shield for coupling heaters  

DOE Patents [OSTI]

Systems for coupling end portions of two elongated heater portions and methods of using such systems to treat a subsurface formation are described herein. A system may include a holding system configured to hold end portions of the two elongated heater portions so that the end portions are abutted together or located near each other; a shield for enclosing the end portions, and one or more inert gas inlets configured to provide at least one inert gas to flush the system with inert gas during welding of the end portions. The shield may be configured to inhibit oxidation during welding that joins the end portions together. The shield may include a hinged door that, when closed, is configured to at least partially isolate the interior of the shield from the atmosphere. The hinged door, when open, is configured to allow access to the interior of the shield.

Menotti, James Louis (Dickinson, TX)

2010-03-09T23:59:59.000Z

224

Regenerative Boiler Feedwater Heater Economics  

E-Print Network [OSTI]

REGENERATIVE BOILER FEEDWATER HEATER ECONOMICS William L. Viar, PE waterland, Viar & Associates, Inc. Wilmington, Delaware ABSTRACT The basic Rankine Vapor Cycle has been r,~peatedly modified to improve efficiency. Always, the objective....g., first and second laws of thermodynamics) have improved and contributed to the evolution. The demands for larger systems with higher performance have been persistent. Progress i ve changes in the app1icat ion of the fundamental Rankine cycle have...

Viar, W. L.

225

DOE EPCA Commercial Refrigeration Standards - EERE-2010-BT-STD-0003 / (RIN)  

Broader source: Energy.gov (indexed) [DOE]

DOE EPCA Commercial Refrigeration Standards - EERE-2010-BT-STD-0003 DOE EPCA Commercial Refrigeration Standards - EERE-2010-BT-STD-0003 / (RIN) 1904-AC19 DOE EPCA Commercial Refrigeration Standards - EERE-2010-BT-STD-0003 / (RIN) 1904-AC19 In today's call we discussed the new CRE proposed standard and how ControlTec anti-sweat controls can help meet those standards without sacrificing equipment performance or integrity. We have a revolutionary product that is the only in the business that has built in Measurement & Verification (M&V). All other anti-sweat heater controls are old technology that has algorithm's to estimate store conditions inaccurately. EPCA Commercial Refrigeration Standards.pdf More Documents & Publications General Electric: ENERGY STAR Referral (PFSF5NFZ****) Docket No. EERE- 2008-BT-STD-0005, RIN 1904-AB57 Ex parte

226

Performance improvement of direct- and indirect-fired heaters  

SciTech Connect (OSTI)

The operating performance of direct and indirect heaters is discussed, and principles and guidelines that can be applied to effect improvements in efficiency are presented. This paper also discusses the associated heater efficiencies and several useful operating techniques to approach the maximum, steady-state heater efficiency. The techniques presented apply to all types of direct-and indirect-fired heaters: salt bath heaters, propane vaporizers, heater/treaters, production heaters, and glycol and amine regenerators.

Sams, G.W.; Hunter, J.D.

1988-08-01T23:59:59.000Z

227

Adjusting alloy compositions for selected properties in temperature limited heaters  

DOE Patents [OSTI]

Heaters for treating a subsurface formation are described herein. Such heaters can be obtained by using the systems and methods described herein. The heater includes a heater section including iron, cobalt, and carbon. The heater section has a Curie temperature less than a phase transformation temperature. The Curie temperature is at least 740.degree. C. The heater section provides, when time varying current is applied to the heater section, an electrical resistance.

Brady; Michael Patrick (Oak Ridge, TN), Horton, Jr.; Joseph Arno (Oak Ridge, TN), Vitek; John Michael (Oak Ridge, TN)

2010-03-23T23:59:59.000Z

228

Downhole pulse tube refrigerators  

SciTech Connect (OSTI)

This report summarizes a preliminary design study to explore the plausibility of using pulse tube refrigeration to cool instruments in a hot down-hole environment. The original motivation was to maintain Dave Reagor`s high-temperature superconducting electronics at 75 K, but the study has evolved to include three target design criteria: cooling at 30 C in a 300 C environment, cooling at 75 K in a 50 C environment, cooling at both 75 K and 30 C in a 250 C environment. These specific temperatures were chosen arbitrarily, as representative of what is possible. The primary goals are low cost, reliability, and small package diameter. Pulse-tube refrigeration is a rapidly growing sub-field of cryogenic refrigeration. The pulse tube refrigerator has recently become the simplest, cheapest, most rugged and reliable low-power cryocooler. The authors expect this technology will be applicable downhole because of the ratio of hot to cold temperatures (in absolute units, such as Kelvin) of interest in deep drilling is comparable to the ratios routinely achieved with cryogenic pulse-tube refrigerators.

Swift, G.; Gardner, D. [Los Alamos National Lab., NM (United States). Condensed Matter and Thermal Physics Group

1997-12-01T23:59:59.000Z

229

Calculational criticality analyses of 10- and 20-MW UF{sub 6} freezer/sublimer vessels  

SciTech Connect (OSTI)

Calculational criticality analyses have been performed for 10- and 20-MW UF{sub 6} freezer/sublimer vessels. The freezer/sublimers have been analyzed over a range of conditions that encompass normal operation and abnormal conditions. The effects of HF moderation of the UF{sub 6} in each vessel have been considered for uranium enriched between 2 and 5 wt % {sup 235}U. The results indicate that the nuclearly safe enrichments originally established for the operation of a 10-MW freezer/sublimer, based on a hydrogen-to-uranium moderation ratio of 0.33, are acceptable. If strict moderation control can be demonstrated for hydrogen-to-uranium moderation ratios that are less than 0.33, then the enrichment limits for the 10-MW freezer/sublimer may be increased slightly. The calculations performed also allow safe enrichment limits to be established for a 20-NM freezer/sublimer under moderation control.

Jordan, W.C.

1993-02-01T23:59:59.000Z

230

Calculational criticality analyses of 10- and 20-MW UF[sub 6] freezer/sublimer vessels  

SciTech Connect (OSTI)

Calculational criticality analyses have been performed for 10- and 20-MW UF[sub 6] freezer/sublimer vessels. The freezer/sublimers have been analyzed over a range of conditions that encompass normal operation and abnormal conditions. The effects of HF moderation of the UF[sub 6] in each vessel have been considered for uranium enriched between 2 and 5 wt % [sup 235]U. The results indicate that the nuclearly safe enrichments originally established for the operation of a 10-MW freezer/sublimer, based on a hydrogen-to-uranium moderation ratio of 0.33, are acceptable. If strict moderation control can be demonstrated for hydrogen-to-uranium moderation ratios that are less than 0.33, then the enrichment limits for the 10-MW freezer/sublimer may be increased slightly. The calculations performed also allow safe enrichment limits to be established for a 20-NM freezer/sublimer under moderation control.

Jordan, W.C.

1993-02-01T23:59:59.000Z

231

Proceedings: Commercial Refrigeration Research Workshop  

SciTech Connect (OSTI)

Improving refrigeration systems for commercial use can enhance both utility load factors and supermarket profits. This workshop has pinpointed research needs in commercial refrigeration and systems integration for a supermarket environment.

None

1984-10-01T23:59:59.000Z

232

Waste Heat Recovery from Refrigeration  

E-Print Network [OSTI]

heat recovery from refrigeration machines is a concept which has great potential for implementation in many businesses. If a parallel requirement for refrigeration and hot water exists, the installation of a system to provide hot water as a by...

Jackson, H. Z.

1982-01-01T23:59:59.000Z

233

Refrigeration monitor and alarm system  

SciTech Connect (OSTI)

A monitor is described for a refrigeration system including a heat reclaiming system coupled therewith, comprising: a sensor positioned to detect the level of liquid state refrigerant in the system and provide an electrical output signal therefrom; a digital display for displaying the refrigerant level; first circuit means coupling the digital display to the sensor for actuating the digital display; and lockout means coupled with the sensor for deactivating the heat reclaiming system when a preselected refrigerant level is reached.

Branz, M.A.; Renaud, P.F.

1986-09-23T23:59:59.000Z

234

CO2 Conversion By Nano Heaters  

SciTech Connect (OSTI)

A graduate student named Oshadha Ranasingha created this animation on the research he performed on nano heaters while working at NETL.

None

2014-03-11T23:59:59.000Z

235

CO2 Heat Pump Water Heater  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

CO 2 Heat Pump Water Heater 2014 Building Technologies Office Peer Review Evaporator Kyle Gluesenkamp, gluesenkampk@ornl.gov Oak Ridge National Laboratory Project Summary Timeline:...

236

CO2 Conversion By Nano Heaters  

ScienceCinema (OSTI)

A graduate student named Oshadha Ranasingha created this animation on the research he performed on nano heaters while working at NETL.

None

2014-06-23T23:59:59.000Z

237

Parallel heater system for subsurface formations  

DOE Patents [OSTI]

A heating system for a subsurface formation is disclosed. The system includes a plurality of substantially horizontally oriented or inclined heater sections located in a hydrocarbon containing layer in the formation. At least a portion of two of the heater sections are substantially parallel to each other. The ends of at least two of the heater sections in the layer are electrically coupled to a substantially horizontal, or inclined, electrical conductor oriented substantially perpendicular to the ends of the at least two heater sections.

Harris, Christopher Kelvin (Houston, TX); Karanikas, John Michael (Houston, TX); Nguyen, Scott Vinh (Houston, TX)

2011-10-25T23:59:59.000Z

238

Helium dilution refrigeration  

E-Print Network [OSTI]

. 1875" OD exchanger Qu ID copper cap Fig. 6. Assembled view of 3He - He dilution refrigerator. 26 The joint thru the tubing wall and the joining of the two sizes of capillary were silver soldered (35/ silver content). A 0. 250" OD tube... the inert atmosphere inside the refrigerator. After removal from the nitrogen atmosphere the graphite support, was 'attached to the still and mixing chamber using Stycast 2850 GT with catalyst g9 ). The mass of the graphite 26 support 1s 11. 62 grams...

McKee, Thomas Raymond

2012-06-07T23:59:59.000Z

239

Combustion heater for oil shale  

DOE Patents [OSTI]

A combustion heater for oil shale heats particles of spent oil shale containing unburned char by burning the char. A delayed fall is produced by flowing the shale particles down through a stack of downwardly sloped overlapping baffles alternately extending from opposite sides of a vertical column. The delayed fall and flow reversal occurring in passing from each baffle to the next increase the residence time and increase the contact of the oil shale particles with combustion supporting gas flowed across the column to heat the shale to about 650 to 700/sup 0/C for use as a process heat source.

Mallon, R.; Walton, O.; Lewis, A.E.; Braun, R.

1983-09-21T23:59:59.000Z

240

Combustion heater for oil shale  

DOE Patents [OSTI]

A combustion heater for oil shale heats particles of spent oil shale containing unburned char by burning the char. A delayed fall is produced by flowing the shale particles down through a stack of downwardly sloped overlapping baffles alternately extending from opposite sides of a vertical column. The delayed fall and flow reversal occurring in passing from each baffle to the next increase the residence time and increase the contact of the oil shale particles with combustion supporting gas flowed across the column to heat the shale to about 650.degree.-700.degree. C. for use as a process heat source.

Mallon, Richard G. (Livermore, CA); Walton, Otis R. (Livermore, CA); Lewis, Arthur E. (Los Altos, CA); Braun, Robert L. (Livermore, CA)

1985-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Enhanced naphthenic refrigeration oils for household refrigerator systems  

SciTech Connect (OSTI)

Due to industry concerns about the successful employment of hydrofluorocarbon-immiscible hydrocarbon oils in refrigeration systems, enhanced naphthenic refrigeration oils have been developed. These products have been designed to be more dispersible with hydrofluorocarbon (HFC) refrigerants, such as R-134a, in order to facilitate lubricant return to the compressor and to ensure proper energy efficiency of the system. Bench tests and system performance evaluations indicate the feasibility of these oils for use in household refrigeration applications. Results of these evaluations are compared with those obtained with polyol esters and typical naphthenic mineral oils employed in chlorofluorocarbon (CFC) and hydrochlorofluorocarbon (HCFC) refrigeration applications.

Reyes-Gavilan, J.L.; Flak, G.T.; Tritcak, T.R. [Witco Corp., Oakland, NJ (United States); Barbour, C.B. [Americold, Cullman, AL (United States)

1997-12-31T23:59:59.000Z

242

An International Survey of Electric Storage Tank Water Heater Efficiency and Standards  

SciTech Connect (OSTI)

Water heating is a main consumer of energy in households, especially in temperate and cold climates. In South Africa, where hot water is typically provided by electric resistance storage tank water heaters (geysers), water heating energy consumption exceeds cooking, refrigeration, and lighting to be the most consumptive single electric appliance in the home. A recent analysis for the Department of Trade and Industry (DTI) performed by the authors estimated that standing losses from electric geysers contributed over 1,000 kWh to the annual electricity bill for South African households that used them. In order to reduce this burden, the South African government is currently pursuing a programme of Energy Efficiency Standards and Labelling (EES&L) for electric appliances, including geysers. In addition, Eskom has a history of promoting heat pump water heaters (HPWH) through incentive programs, which can further reduce energy consumption. This paper provides a survey of international electric storage water heater test procedures and efficiency metrics which can serve as a reference for comparison with proposed geyser standards and ratings in South Africa. Additionally it provides a sample of efficiency technologies employed to improve the efficiency of electric storage water heaters, and outlines programs to promote adoption of improved efficiency. Finally, it surveys current programs used to promote HPWH and considers the potential for this technology to address peak demand more effectively than reduction of standby losses alone

Johnson, Alissa; Lutz, James; McNeil, Michael A.; Covary, Theo

2013-11-13T23:59:59.000Z

243

A Study on the Failure of Industrial Electric Heater  

E-Print Network [OSTI]

The break down mechanism of a cylindrical electric heater is investigated by studying the uneven heating behavior of the heater by measuring the surface temperature variation of the heater when it is subjected to a boundary condition of constant...

Chyu, M. C.

244

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network [OSTI]

M.V. Lapsa. 2001. Residential Heat Pump Water Heater (HPWH)Calwell. 2005. Residential Heat Pump Water Heaters: EnergyA Specification for Residential Heat Pump Water Heaters

Franco, Victor

2011-01-01T23:59:59.000Z

245

Jefferson Lab Science Series - Living and Working in the Freezer  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Volcanoes in Virginia! Volcanoes in Virginia! Previous Video (Volcanoes in Virginia!) Science Series Video Archive Next Video (You Already Know This Physics!) You Already Know This Physics! Living and Working in the Freezer Dr. Victoria Hill - Old Dominion University, Bio-Optics Group February 7, 2012 Very little data of any kind exists from the early spring in the Arctic. The reason? It's extremely cold and that makes it difficult to survive, let alone conduct science. From March through the end of April, 2011, scientists from around the world braved temperatures of -48°C in the high Canadian Arctic in the name of science. At the Catlin Arctic Survey's floating 'Ice Base' off Ellef Ringnes Island, Dr. Victoria Hill was investigating how organic material in fresh water near the surface of the

246

Uranium hexaflouride freezer/sublimer process simulator/trainer  

SciTech Connect (OSTI)

This paper describes a software and hardware simulation of a freezer/sublimer unit used in gaseous diffusion processing of uranium hexafluoride (UF{sub 6}). The objective of the project was to build a plant simulator that reads control signals and produces plant signals to mimic the behavior of an actual plant. The model is based on physical principles and process data. Advanced Continuous Simulation Language (ACSL) was used to develop the model. Once the simulation was validated with actual plant process data, the ACSL model was translated into Advanced Communication and Control Oriented Language (ACCOL). A Bristol Babcock Distributed Process Controller (DPC) Model 3330 was the hardware platform used to host the ACCOL model and process the real world signals. The DPC will be used as a surrogate plant to debug control system hardware/software and to train operators to use the new distributed control system without disturbing the process. 2 refs., 4 figs.

Carnal, C.L. (Tennessee Technological Univ., Cookeville, TN (USA)); Belcher, J.D.; Tapp, P.A.; Ruppel, F.R.; Wells, J.C. (Oak Ridge National Lab., TN (USA))

1991-01-01T23:59:59.000Z

247

Field Demonstration of High Efficiency Gas Heaters  

Broader source: Energy.gov [DOE]

For many buildings that do not require space cooling, non-centralized equipment such as unit heaters provide space heating to building occupants. Unit heaters are a major source of energy use nationally, accounting for nearly 18% of primary space heating energy use for commercial buildings, and most prominently appear in warehouses, distribution centers, loading docks, etc.

248

Subsurface connection methods for subsurface heaters  

DOE Patents [OSTI]

A system for heating a subsurface formation is described. The system includes a first elongated heater in a first opening in the formation. The first elongated heater includes an exposed metal section in a portion of the first opening. The portion is below a layer of the formation to be heated. The exposed metal section is exposed to the formation. A second elongated heater is in a second opening in the formation. The second opening connects to the first opening at or near the portion of the first opening below the layer to be heated. At least a portion of an exposed metal section of the second elongated heater is electrically coupled to at least a portion of the exposed metal section of the first elongated heater in the portion of the first opening below the layer to be heated.

Vinegar, Harold J. (Bellaire, TX); Bass, Ronald Marshall (Houston, TX); Kim, Dong Sub (Sugar Land, TX); Mason, Stanley Leroy (Allen, TX); Stegemeier, George Leo (Houston, TX); Keltner, Thomas Joseph (Spring, TX); Carl, Jr., Frederick Gordon (Houston, TX)

2010-12-28T23:59:59.000Z

249

Absorption Heat Pump Water Heater - 2013 Peer Review | Department...  

Energy Savers [EERE]

Absorption Heat Pump Water Heater - 2013 Peer Review Absorption Heat Pump Water Heater - 2013 Peer Review Emerging Technologies Project for the 2013 Building Technologies Office's...

250

Residential Absorption Heat Pump Water Heater | Department of...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Heat Pump Water Heater Residential Absorption Heat Pump Water Heater Photo credit: Oak Ridge National Lab Photo credit: Oak Ridge National Lab Diagram of absorption heat...

251

Ex Parte Memorandum on Grid-Enabled Water Heaters | Department...  

Energy Savers [EERE]

with DOE representatives regarding water heater standards and thermal storage and demand response programs. DOE exparte memo100213 Grid-EnabledWaterHeaterAmendment More...

252

Covered Product Category: Residential Heat Pump Water Heaters...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Residential Heat Pump Water Heaters Covered Product Category: Residential Heat Pump Water Heaters The Federal Energy Management Program (FEMP) provides acquisition guidance and...

253

Efficient Residential Water Heaters Webinar | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Weatherization Assistance Program Pilot Projects Efficient Residential Water Heaters Webinar Efficient Residential Water Heaters Webinar On Feb. 22, 2011, Jerone Gagliano,...

254

Covered Product Category: Residential Gas Storage Water Heaters...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Storage Water Heaters Covered Product Category: Residential Gas Storage Water Heaters The Federal Energy Management Program (FEMP) provides acquisition guidance for gas storage...

255

Energy Cost Calculator for Electric and Gas Water Heaters | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Electric and Gas Water Heaters Energy Cost Calculator for Electric and Gas Water Heaters Vary equipment size, energy cost, hours of operation, and or efficiency level. INPUT...

256

WICF Certification, Compliance and Enforcement webinar | Department...  

Broader source: Energy.gov (indexed) [DOE]

DOE Certification, Compliance, and Enforcement Overview for Refrigerators, Refrigerator-Freezers, Freezers, Dehumidifiers, Room Air Conditioners, Clothes Washers, Clothes...

257

Ex parte Communication | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

proposed rulemaking on energy conservation standards for residential refrigerators, refrigerator-freezers, and freezers. Ex parte Communication More Documents & Publications...

258

EA-1138: Final Environmental Assessment | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Environmental Assessment Proposed Energy Conservation Standards for Refrigerators, Refrigerator-Freezers, and Freezers This Environmental Assessment (EA) presents the associated...

259

DOE Publishes Notice of Proposed Rulemaking for Residential Water Heater and Certain Commercial Water Heater Test Procedures  

Broader source: Energy.gov [DOE]

The Department of Energy has published a notice of proposed rulemaking regarding test procedures for residential water heaters and certain commercial water heaters.

260

Tankless or Demand-Type Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tankless or Demand-Type Water Heaters Tankless or Demand-Type Water Heaters Tankless or Demand-Type Water Heaters May 2, 2012 - 6:47pm Addthis Diagram of a tankless water heater. Diagram of a tankless water heater. How does it work? Tankless water heaters deliver hot water as it is needed, eliminating the need for storage tanks. Tankless water heaters, also known as demand-type or instantaneous water heaters, provide hot water only as it is needed. They don't produce the standby energy losses associated with storage water heaters, which can save you money. Here you'll find basic information about how they work, whether a tankless water heater might be right for your home, and what criteria to use when selecting the right model. Check out the Energy Saver 101: Water Heating infographic to learn if a tankless water heater is right for you.

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Asset Management Equipment Disposal Form -Refrigerant Recovery  

E-Print Network [OSTI]

enters the waste stream with the charge intact (e.g., motor vehicle air conditioners, refrigeratorsAsset Management Equipment Disposal Form - Refrigerant Recovery Safe Disposal Requirements Under refrigeration, cold storage warehouse refrigeration, chillers, and industrial process refrigeration) has to have

Sin, Peter

262

Multilayer Thermionic Refrigeration  

SciTech Connect (OSTI)

A review is presented of our program to construct an efficient solid state refrigerator based on thermionic emission of electrons over periodic barriers in the solid. The experimental program is to construct a simple device with one barrier layer using a three layers: metal-semiconductor-metal. The theoretical program is doing calculations to determine: (i) the optimal layer thickness, and (ii) the thermal conductivity.

Mahan, G.D.

1999-08-30T23:59:59.000Z

263

DOE Testing Finds Two Kenmore-Brand Freezers Noncompliant | Department of  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Testing Finds Two Kenmore-Brand Freezers Noncompliant Testing Finds Two Kenmore-Brand Freezers Noncompliant DOE Testing Finds Two Kenmore-Brand Freezers Noncompliant August 13, 2012 - 1:53pm Addthis The U.S. Department of Energy's ("DOE") Office of Enforcement recently issued a Notice of Noncompliance Determination to Sears, Roebuck & Co. ("Sears") regarding two Kenmore-brand chest freezers, basic model 255.19502010 ("19502" or "1950") and basic model 255.19702010 ("19702" or "1970"), which are privately labeled and distributed in commerce in the U.S. by Sears and manufactured in China. In late 2011 and early 2012, DOE tested four units of basic model 19702 and four units of basic model 19502. DOE's testing demonstrated that neither basic model is in compliance with federal law. Basic model 19702

264

Miniature liquid?3He refrigerator  

Science Journals Connector (OSTI)

The use of a cryopump and high?pressure internal storage of the cryogen makes it possible to miniaturize a one?shot recyclable 3He refrigerator while at the same time improving its performance. Because of their simplified interface requirements such refrigerators are readily incorporated into existing 4He cryostats allowing a convenient extension of their operating range down to 0.3 K. An analysis of the parameters describing refrigerator performance (condensation time heat transfer to the 4He bath lifetime and refrigeration power) leads to the definition of an optimized refrigerator. Measured performance characteristics of a miniature [2?l standard temperature and pressure (STP) of 3He] refrigerator used in laboratory and stratospheric balloon?borne experiments are given.

J. P. Torre; G. Chanin

1985-01-01T23:59:59.000Z

265

Vaccine refrigerator testing. Final report  

SciTech Connect (OSTI)

For the Central American Health Clinic Project initiated in 1986, Sandia National Laboratories and the Florida Solar Energy Center recognized the need for a test and evaluation program for vaccine refrigeration systems. At the Florida Solar Energy Center, side-by-side testing of three photovoltaic powered vaccine refrigerators began in 1987. The testing was expanded in 1988 to include a kerosene absorption refrigerator. This report presents observations, conclusions, and recommendations derived from testing the four vaccine refrigeration systems. Information is presented pertaining to the refrigerators, photovoltaic arrays, battery subsystems, charge controllers, and user requirements. This report should be of interest to designers, manufacturers, installers, and users of photovoltaic-powered vaccine refrigeration systems and components.

Ventre, G.G. [Univ. of Central Florida, Orlando, FL (United States); Kilfoyle, D.; Marion, B. [Florida Solar Energy Center, Cape Canaveral, FL (United States)

1990-06-01T23:59:59.000Z

266

NICE3: Industrial Refrigeration System  

SciTech Connect (OSTI)

Energy Concepts has developed an absorption-augmented system as a cost-effective means of achieving more cooling capacity with a substantial reduction in energy consumption and greenhouse gas emissions for industrial refrigeration. It cuts fuel consumption by 30% by combining an internal combustion engine with a mechanical compression refrigeration system and an absorption refrigeration system. The absorption system is powered by engine waste heat. Conventional industrial refrigeration uses mechanical vapor compression, powered by electric motors, which results in higher energy costs. By the year 2010, the new system could cut fuel consumption by 19 trillion Btu and greenhouse emissions by more than 1 million tons per year.

Simon, P.

1999-09-29T23:59:59.000Z

267

Tankless Water Heaters: Do They Really Work?  

Broader source: Energy.gov (indexed) [DOE]

Tankless Water Heaters: Do They Tankless Water Heaters: Do They Really Work? Center for Energy and Environment, NorthernSTAR, Ben Schoenbauer Context * Domestic Water Heating is the next big residential energy in efficiency. - Space heating loads are being reduced - Largest peak load in almost all homes is water heating - Annual water heating load is larger than annual space heating load in many homes - Most DHW equipment is inefficiency 50-60% Technical Approach * TWHs and condensing TWHs have significant energy savings potential - Do these ratings relate to real world performance? - How do TWHs compare to standard water heaters? - What performance/install issues do they have? * 10 home 26 water heater alternating mode field study was conducted Recommended Guidance * In situations where economics are

268

Solar Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heaters Solar Water Heaters Solar Water Heaters May 7, 2012 - 9:52am Addthis Solar water heaters -- also called solar domestic hot water systems -- can be a cost-effective way to generate hot water for your home. They can be used in any climate, and the fuel they use -- sunshine -- is free. How They Work Solar water heating systems include storage tanks and solar collectors. There are two types of solar water heating systems: active, which have circulating pumps and controls, and passive, which don't. Active Solar Water Heating Systems There are two types of active solar water heating systems: Direct circulation systems Pumps circulate household water through the collectors and into the home. They work well in climates where it rarely freezes. Indirect circulation systems

269

Solar water heaters | Open Energy Information  

Open Energy Info (EERE)

heaters heaters Jump to: navigation, search (The following text is derived from the United States Department of Energy's description of Solar Water Heating technology.)[1] Solar Water Heater One of the most cost-effective ways to include renewable technologies into a building is by incorporating solar hot water. A typical residential solar water-heating system reduces the need for conventional water heating by about two-thirds. It minimizes the expense of electricity or fossil fuel to heat the water and reduces the associated environmental impacts. Solar Water Heating for Buildings Most solar water-heating systems for buildings have two main parts: (1) a solar collector and (2) a storage tank. The most common collector used in solar hot water systems is the flat-plate collector. Solar water heaters use the sun to heat either water

270

Heater head for a Stirling engine  

SciTech Connect (OSTI)

A heater head is described for a compound Stirling engine modules, each including a displacer cylinder coaxially aligned with the displacer cylinder of the other of the engine modules, a displacer piston mounted for reciprocation in the displacer cylinder.

Darooka, D.K.

1988-09-06T23:59:59.000Z

271

Arnold Schwarzenegger WATER HEATERS AND HOT WATER  

E-Print Network [OSTI]

Arnold Schwarzenegger Governor WATER HEATERS AND HOT WATER DISTRIBUTION SYSTEMS;#12;Appendices Appendix A. Multifamily Water Heating Construction Practices, Pricing and Availability Survey Report Appendix B. Multifamily Water Heating Controls Performance Field Report Appendix C. Pipe

272

Heat Pump Water Heaters Demonstration Project  

Broader source: Energy.gov (indexed) [DOE]

Heat Pump Water Heaters Heat Pump Water Heaters Demonstration Project Building America Stakeholder Meeting Ron Domitrovic Ammi Amarnath 3/1/2012 Austin, TX 2 © 2011 Electric Power Research Institute, Inc. All rights reserved. HPWH Field Demonstration: Research Objectives * Assess heat pump water heater technology by measuring efficiency. * Provide credible data on the performance and reliability of heat pump water heaters. * Assess user satisfaction in a residential setting. 3 © 2011 Electric Power Research Institute, Inc. All rights reserved. Demonstration Host Utilities Target: 40 Units per Utility Installed and Potential Sites by Climate Zone Source: Department of Energy (DOE), Building America climate regions 4 © 2011 Electric Power Research Institute, Inc. All rights reserved. Installation Locations-Southern Company Region

273

E-Print Network 3.0 - adiabatic demagnetization refrigerator...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

refrigerator Search Powered by Explorit Topic List Advanced Search Sample search results for: adiabatic demagnetization refrigerator...

274

Varying properties along lengths of temperature limited heaters  

DOE Patents [OSTI]

A system for heating a subsurface formation is described. The system includes an elongated heater in an opening in the formation. The elongated heater includes two or more portions along the length of the heater that have different power outputs. At least one portion of the elongated heater includes at least one temperature limited portion with at least one selected temperature at which the portion provides a reduced heat output. The heater is configured to provide heat to the formation with the different power outputs. The heater is configured so that the heater heats one or more portions of the formation at one or more selected heating rates.

Vinegar, Harold J. (Bellaire, TX); Xie, Xueying (Houston, TX); Miller, David Scott (Katy, TX); Ginestra, Jean Charles (Richmond, TX)

2011-07-26T23:59:59.000Z

275

Phase change material storage heater  

DOE Patents [OSTI]

A storage heater for storing heat and for heating a fluid, such as water, has an enclosure defining a chamber therein. The chamber has a lower portion and an upper portion with a heating element being disposed within the enclosure. A tube through which the fluid flows has an inlet and an outlet, both being disposed outside of the enclosure, and has a portion interconnecting the inlet and the outlet that passes through the enclosure. A densely packed bed of phase change material pellets is disposed within the enclosure and is surrounded by a viscous liquid, such as propylene glycol. The viscous liquid is in thermal communication with the heating element, the phase change material pellets, and the tube and transfers heat from the heating element to the pellets and from the pellets to the tube. The viscous fluid has a viscosity so that the frictional pressure drop of the fluid in contact with the phase change material pellets substantially reduces vertical thermal convection in the fluid. As the fluid flows through the tube heat is transferred from the viscous liquid to the fluid flowing through the tube, thereby heating the fluid.

Goswami, D. Yogi (Gainesville, FL); Hsieh, Chung K. (Gainesville, FL); Jotshi, Chand K. (Gainesville, FL); Klausner, James F. (Gainesville, FL)

1997-01-01T23:59:59.000Z

276

Diesel particulate filter with zoned resistive heater  

DOE Patents [OSTI]

A diesel particulate filter assembly comprises a diesel particulate filter (DPF) and a heater assembly. The DPF filters a particulate from exhaust produced by an engine. The heater assembly has a first metallic layer that is applied to the DPF, a resistive layer that is applied to the first metallic layer, and a second metallic layer that is applied to the resistive layer. The second metallic layer is etched to form a plurality of zones.

Gonze, Eugene V [Pinckney, MI

2011-03-08T23:59:59.000Z

277

Reducing NOx in Fired Heaters and Boilers  

E-Print Network [OSTI]

-6, 2000 Reducing NOx in Fired Heaters Air Pollution Control and Boilers Keeping the environment clean Presented by Ashutosh Garg Furnace Improvements Low cost solutions for fired heaters Trace compounds ? Nitric oxides ? Carbon monoxide ? Sulfur... it is essential to estimate accurately baseline NOx emissions. ? This will establish each units current compliance status. ? Emissions ? Current excess air level ? Carbon monoxide ? Combustibles ? NOx corrected to 3% 02 314 ESL-IE-00-04-46 Proceedings...

Garg, A.

278

Sizing a New Water Heater | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Sizing a New Water Heater Sizing a New Water Heater Sizing a New Water Heater May 29, 2012 - 7:16pm Addthis Is your water heater the right size for you house? | Photo credit ENERGY STAR® Is your water heater the right size for you house? | Photo credit ENERGY STAR® A properly sized water heater will meet your household's hot water needs while operating more efficiently. Therefore, before purchasing a water heater, make sure it's the correct size. Here you'll find information about how to size these systems: Tankless or demand-type water heaters Solar water heating system Storage and heat pump (with tank) water heaters. For sizing combination water and space heating systems -- including some heat pump systems, and tankless coil and indirect water heaters -- consult a qualified contractor.

279

Selecting a New Water Heater | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Selecting a New Water Heater Selecting a New Water Heater Selecting a New Water Heater August 29, 2012 - 7:30pm Addthis Water heater testing facility at Oak Ridge National Laboratory. Water heater testing facility at Oak Ridge National Laboratory. When selecting a new water heater for your home, choose a water heating system that will not only provide enough hot water but also that will do so energy efficiently, saving you money. This includes considering the different types of water heaters available and determining the right size and fuel source for your home. Check out the Energy Saver 101: Water Heating infographic to learn more about the different types of water heaters and how to select the right model for your home. Types of Water Heaters It's a good idea to know the different types of water heaters available

280

Gunnison County Electric - Residential Energy Efficiency Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

Gunnison County Electric - Residential Energy Efficiency Rebate Gunnison County Electric - Residential Energy Efficiency Rebate Program Gunnison County Electric - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Appliances & Electronics Heating & Cooling Commercial Heating & Cooling Heat Pumps Commercial Lighting Lighting Water Heating Program Info State Colorado Program Type Utility Rebate Program Rebate Amount Dishwashers: $45/unit Clothes Washers: $60/unit Refrigerators: $60/unit Freezers: $60/unit Refrigerator Recycling: $40/unit Freezer Recycling: $40/unit Electric Water Heaters (30-gal capacity, 6-year warranty, mandated EF rating): $70/unit Super Efficient Water Heater: $120/unit (primary heating must be from geothermal heat pump) Water Heaters (lifetime warranty): Additional $25/unit

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Energy-conservation program: notice of proposed rulemaking  

SciTech Connect (OSTI)

A notice of proposed rulemaking, proposing energy efficiency standards for refrigerators, refrigerator-freezers, freezers, clothes dryers, water heaters, room air conditioners, home heating equipment (not including furnaces) kitchen ranges and ovens, and central air conditioners ispresented. Comments are invited and the procedure for public comment is detailed. Issues included and presented in the proposed rulemaking are: determination of energy efficiency levels, macro-economic analysis, certification and enforcement, effect on other law, small business exemptions, environmental assessment, and regulatory analysis. (MCW)

Not Available

1980-06-12T23:59:59.000Z

282

Modular thermoacoustic refrigerator  

Science Journals Connector (OSTI)

A thermoacousticrefrigerator was built to explore scaling to large heat flux. The refrigerator was constructed according to a modular design so that various stack heat exchanger and resonator sections are easily interchangeable. The resonator is driven by a commercial 10?in. woofer. Initial tests using pure helium gas as the working fluid and steel honeycomb (0.8?mm cell) for the stack pumped 60 W of heat against a 10?°C temperature gradient. Measurements of heat flux and efficiency will be reported as functions of stack structure (e.g. pore size and shape) and will be compared with theoretical predictions.

Steven R. Murrell; George Mozurkewich

1993-01-01T23:59:59.000Z

283

The refrigerator revolution  

SciTech Connect (OSTI)

This article discusses how a simple, new technology threw the best-laid plans of the chemical and refrigerator industries into disarray-and provided a new perspective on how future environmental agreements can be reached. In recent years, a series of massive business mergers has mesmerized the industrial world. However in the early 1990s a German environmentalist, triggered global reprocussions in the wake of the mandate to phase out the use of ozone depleting substances. The economic and political background of this is explained in detail.

Ayres, E.; French, H.

1996-09-01T23:59:59.000Z

284

Control of household refrigerators. Part 2: Alternate control approaches for improving temperature performance and reducing energy use  

SciTech Connect (OSTI)

In Part 1 it was shown that conventional control of household refrigerators is achieved by regulating the distribution of air in the freezer compartment to all other parts of the plant. In Part 2 three alternative approaches to the conventional control of a top-mount refrigerator are presented: variable temperature bandwidths, uncoupled compressor and evaporator fan, and the combination of these two. These allowed the plant to achieve near-ideal control with respect to improved temperature performance in each compartment. Automatic airflow dampers were used with the dual controllers to independently regulate refrigerator compartment temperature. Plant performance was simulated using a model that computes the refrigerant and airflow systems behavior. Together, these alternate configurations and approaches define new control algorithms that reveal the plant's optimal control model for improving performance and energy usage relative to conventional controllers. Results based on model simulations are dependent upon the model's accuracy and validity. However, the model validation studies cited here, though limited in scope, do show agreement between simulation and experimental data for the ambient temperatures and thermal load conditions considered. This suggests that these model results are reasonable, and representative of actual plant behavior under these conditions and configurations for a top-mount style refrigerator plant.

Graviss, K.J.; Collins, R.L.

1999-07-01T23:59:59.000Z

285

Semiconductor-based optical refrigerator  

DOE Patents [OSTI]

Optical refrigerators using semiconductor material as a cooling medium, with layers of material in close proximity to the cooling medium that carries away heat from the cooling material and preventing radiation trapping. In addition to the use of semiconducting material, the invention can be used with ytterbium-doped glass optical refrigerators.

Epstein, Richard I. (Santa Fe, NM); Edwards, Bradley C. (Nekoosa, WI); Sheik-Bahae, Mansoor (Albuquerque, NM)

2002-01-01T23:59:59.000Z

286

Load Forecasting of Supermarket Refrigeration  

E-Print Network [OSTI]

energy system. Observed refrigeration load and local ambient temperature from a Danish su- permarket renewable energy, is increasing, therefore a flexible energy system is needed. In the present ThesisLoad Forecasting of Supermarket Refrigeration Lisa Buth Rasmussen Kongens Lyngby 2013 M.Sc.-2013

287

Tankless Coil and Indirect Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tankless Coil and Indirect Water Heaters Tankless Coil and Indirect Water Heaters Tankless Coil and Indirect Water Heaters May 16, 2013 - 7:21pm Addthis An indirect water heater. An indirect water heater. How does it work? Tankless coil and indirect water heaters use your home's heating system to heat water. Tankless coil and indirect water heaters use a home's space heating system to heat water. They're part of what's called integrated or combination water and space heating systems. How They Work A tankless coil water heater provides hot water on demand without a tank. When a hot water faucet is turned on, water is heated as it flows through a heating coil or heat exchanger installed in a main furnace or boiler. Tankless coil water heaters are most efficient during cold months when the heating system is used regularly but can be an inefficient choice for many

288

Tankless Coil and Indirect Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Coil and Indirect Water Heater Basics Coil and Indirect Water Heater Basics Tankless Coil and Indirect Water Heater Basics August 19, 2013 - 3:03pm Addthis Illustration of a tankless coil water heater. The heater is box-shaped, and has two pipes sticking out one end: one a cold water inlet, and one a hot water outlet. These pipes lead into the heater to a cylindrical coil called a heat exchanger. Long tubes surrounding the heat exchanger are labeled the heated water jacket. At the bottom of the box is a row of small flames, called the boiler heat source. Tankless coil and indirect water heaters use a home or building's space heating system to heat water as part of an integrated or combination water and space heating system. How Tankless Coil and Indirect Water Heaters Work A tankless coil water heater uses a heating coil or heat exchanger

289

Aging of Polyurethane Foam Insulation in Simulated Refrigerator Panels--Three-Year Results with Third-Generation Blowing Agents  

SciTech Connect (OSTI)

Laboratory data are presented on the effect of constant-temperature aging on the apparent thermal conductivity of polyurethane foam insulation for refrigerators and freezers. The foam specimens were blown with HCFC-141b and with three of its potential replacements--HFC-134a, HFC-245fa, and cyclopentane. Specimens were aged at constant temperatures of 90 F, 40 F, and -10 F. Thermal conductivity measurements were made on two types of specimens: full-thickness simulated refrigerator panels containing foam enclosed between solid plastic sheets, and thin slices of core foam cut from similar panels. Results are presented for the first three years of a multi-year aging study. Preliminary comparisons of measured data with predictions of a mathematical aging model are presented.

Wilkes, K.E.

2001-05-29T23:59:59.000Z

290

Aging of polyurethane foam insulation in simulated refrigerator panels -- Initial results with third-generation blowing agents  

SciTech Connect (OSTI)

Laboratory data are presented on the effect of constant-temperature aging on the apparent thermal conductivity of polyurethane foam insulation for refrigerators and freezers. The foam specimens were blown with HCFC-141b and with three of its potential replacements -- HFC-134a, HFC-245fa, and cyclopentane. Specimens were aged at constant temperatures of 90 F, 40 F, and {minus}10 F. Thermal conductivity measurements were made on two types of specimens: full-thickness simulated refrigerator panels containing foam enclosed between solid plastic sheets, and thin slices of core foam cut from similar panels. Results are presented for about 250 days of aging for the core-foam specimens and for the first six months of aging for the full-thickness panels.

Wilkes, K.E.; Gabbard, W.A.; Weaver, F.J.

1998-11-01T23:59:59.000Z

291

Aging of Polyurethane Foam Insulation in Simulated Refrigerator Panels--Two-Year Results with Third-Generation Blowing Agents  

SciTech Connect (OSTI)

Laboratory data are presented on the effect of constant-temperature aging on the apparent thermal conductivity of polyurethane foam insulation for refrigerators and freezers. The foam specimens were blown with HCFC-141b and with three of its potential replacements--HFC-134a, HFC-245fa, and cyclopentane. Specimens were aged at constant temperatures of 90 F, 40 F, and {minus}10 F. Thermal conductivity measurements were made on two types of specimens: full-thickness simulated refrigerator panels containing foam enclosed between solid plastic sheets, and thin slices of core foam cut from similar panels. Results are presented for the first two years of a multi-year aging study. Preliminary comparisons of measured data with predictions of a mathematical aging model are presented.

Wilkes, K.E.

2001-02-14T23:59:59.000Z

292

Aging of Polyurethane Foam Insulation in Simulated Refrigerator Panels--One-Year Results with Third-Generation Blowing Agents  

SciTech Connect (OSTI)

Laboratory data are presented on the effect of constant-temperature aging on the apparent thermal conductivity of polyurethane foam insulation for refrigerators and freezers. The foam specimens were blown with HCFC-141b and with three of its potential replacements--HFC-134a, HFC-245fa, and cyclopentane. Specimens were aged at constant temperatures of 90 F, 40 F, and {minus}10 F. Thermal conductivity measurements were made on two types of specimens: full-thickness simulated refrigerator panels containing foam enclosed between solid plastic sheets, and thin slices of core foam cut from similar panels. Results are presented for the first year of a multi-year study for the full-thickness panels and for about 1-1/2 years of aging for the core-foam specimens.

Gabbard, W.A.; Weaver, F.J.; Wilkes, K.E.

1999-09-27T23:59:59.000Z

293

An International Survey of Electric Storage Tank Water Heater Efficiency and Standards  

E-Print Network [OSTI]

Survey of Electric Storage Tank Water Heater Efficiency andSurvey of Electric Storage Tank Water Heater Efficiency andby electric resistance storage tank water heaters (geysers),

Johnson, Alissa

2013-01-01T23:59:59.000Z

294

ENERGY & ENVIRONMENT DIVISION. ANNUAL REPORT FY 1980  

E-Print Network [OSTI]

kWh) (kWh) b b Refrigerator and Freezer (kWh) Source: Unionseveral months for refrigerators and freezers to a maximumPart 2, June, 1980. Refrigerator/freezers Freezers Clothes

Authors, Various

2010-01-01T23:59:59.000Z

295

Temperature limited heaters using phase transformation of ferromagnetic material  

DOE Patents [OSTI]

Systems, methods, and heaters for treating a subsurface formation are described herein. Systems and methods for making heaters are described herein. At least one heater includes a ferromagnetic conductor and an electrical conductor. The electrical conductor is electrically coupled to the ferromagnetic conductor. The heater provides a first amount of heat at a lower temperature. The heater may provide a second reduced amount of heat when the heater reaches a selected temperature, or enters a selected temperature range, at which the ferromagnetic conductor undergoes a phase transformation.

Vitek, John Michael [Oak Ridge, TN; Brady, Michael Patrick [Oak Ridge, TN

2009-10-06T23:59:59.000Z

296

MHD oxidant intermediate temperature ceramic heater study. Final report  

SciTech Connect (OSTI)

The use of three types of directly fired ceramic heaters for preheating oxygen enriched air to an intermediate temperature of 1144K was investigated. The three types of ceramic heaters are: (1) a fixed bed, periodic flow ceramic brick regenerative heater (2) a ceramic pebble regenerative heater. The heater design, performance and operating characteristics under conditions in which the particulate matter is not solidified are evaluated. A comparison and overall evaluation of the three types of ceramic heaters and temperature range determination at which the particulate matter in the MHD exhaust gas is estimated to be a dry powder are presented.

Carlson, A.W.; Chait, I.L.; Saari, D.P.; Marksberry, C.L.

1981-09-01T23:59:59.000Z

297

Cryogenic refrigeration apparatus  

DOE Patents [OSTI]

A technique for producing a cold environment in a refrigerant system in which input fluid from a compressor at a first temperature is introduced into an input channel of the system and is pre-cooled to a second temperature for supply to one of at least two stages of the system, and to a third temperature for supply to another stage thereof. The temperatures at such stages are reduced to fourth and fifth temperatures below the second and third temperatures, respectively. Fluid at the fourth temperature from the one stage is returned through the input channel to the compressor and fluid at the fifth temperature from the other stage is returned to the compressor through an output channel so that pre-cooling of the input fluid to the one stage occurs by regenerative cooling and counterflow cooling and pre-cooling of the input fluid to the other stage occurs primarily by counterflow cooling.

Crunkleton, James A. (Cambridge, MA)

1992-01-01T23:59:59.000Z

298

The Quantum Absorption Refrigerator  

E-Print Network [OSTI]

A quantum absorption refrigerator driven by noise is studied with the purpose of determining the limitations of cooling to absolute zero. The model consists of a working medium coupled simultaneously to hot, cold and noise baths. Explicit expressions for the cooling power are obtained for Gaussian and Poisson white noise. The quantum model is consistent with the first and second laws of thermodynamics. The third law is quantified, the cooling power J_c vanishes as J_c proportional to T_c^{alpha}, when T_c approach 0, where alpha =d+1 for dissipation by emission and absorption of quanta described by a linear coupling to a thermal bosonic field, where d is the dimension of the bath.

Amikam Levy; Ronnie Kosloff

2011-09-04T23:59:59.000Z

299

Solar water heaters | Open Energy Information  

Open Energy Info (EERE)

water heaters water heaters (Redirected from - Solar Hot Water) Jump to: navigation, search (The following text is derived from the United States Department of Energy's description of Solar Water Heating technology.)[1] Solar Water Heater One of the most cost-effective ways to include renewable technologies into a building is by incorporating solar hot water. A typical residential solar water-heating system reduces the need for conventional water heating by about two-thirds. It minimizes the expense of electricity or fossil fuel to heat the water and reduces the associated environmental impacts. Solar Water Heating for Buildings Most solar water-heating systems for buildings have two main parts: (1) a solar collector and (2) a storage tank. The most common collector used in solar hot water systems is the

300

Combined Systems with Tankless Water Heaters  

Broader source: Energy.gov (indexed) [DOE]

Combined Systems with Tankless Water Heaters Combined Systems with Tankless Water Heaters Armin Rudd Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas 2 Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas More builder's wanting to use gas-fired tankless water heaters, and with solar pre-heat  Endless hot water  Helps HERS Index  Space saving 2 3 Residential Energy Efficiency Stakeholder Meeting 2/29 - 3/2/2012 Austin, Texas Problem with elevated TWH inlet temperature 60 70 80 90 100 110 120 130 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 Maximum Inlet Temperature (F) DHW flow rate (gpm) Maximum TWH inlet temperature to stay below 125 F delivered temperature, with 15 kBtu/h minimum firing rate Typical shower temperature 4 Residential Energy Efficiency Stakeholder Meeting

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Solar Water Heater Rebate | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heater Rebate Solar Water Heater Rebate Solar Water Heater Rebate < Back Eligibility Commercial Fed. Government Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Hawaii Program Type State Rebate Program Rebate Amount Residential Solar Water Heating: $1,000 upfront, or Residential Solar Water Heating Interest Loan Buy-Down: $1,000 Residential Solar Attic Fans: $50 Commercial: $250 per 12,000 Btu/hr derated capacity Provider Hawaii Energy Hawaii Energy, a third-party administered public benefits fund, provides incentives for energy efficiency and conservation to customers of the Hawaiian Electric Company (HECO) and its subsidiaries, Maui Electric Company (MECO) and Hawaii Electric Light Company (HELCO). This incentive is available for installations on the islands of Oahu, Hawaii, Maui, Lanai and

302

The New York Power Authority`s energy-efficient refrigerator program for the New York City Housing Authority -- 1997 savings evaluation  

SciTech Connect (OSTI)

This document describes the estimation of the annual energy savings achieved from the replacement of 20,000 refrigerators in New York City Housing Authority (NYCHA) public housing with new, highly energy-efficient models in 1997. The US Department of Housing and Urban Development (HUD) pays NYCHA`s electricity bills, and agreed to reimburse NYCHA for the cost of the refrigerator installations. Energy savings over the lifetime of the refrigerators accrue to HUD. Savings were demonstrated by a metering project and are the subject of the analysis reported here. The New York Power Authority (NYPA) identified the refrigerator with the lowest life-cycle cost, including energy consumption over its expected lifetime, through a request for proposals (RFP) issued to manufacturers for a bulk purchase of 20,000 units in 1997. The procurement was won by Maytag with a 15-ft{sup 3} top-freezer automatic-defrost refrigerator rated at 437 kilowatt-hours/year (kWh/yr). NYCHA then contracted with NYPA to purchase, finance, and install the new refrigerators, and demanufacture and recycle materials from the replaced units. The US Department of Energy (DOE) helped develop and plan the project through the ENERGY STAR{reg_sign} Partnerships program conducted by its Pacific Northwest National Laboratory (PNNL). PNNL designed the metering protocol and occupant survey used in 1997, supplied and calibrated the metering equipment, and managed and analyzed the data collected by NYPA. The objective of the 1997 metering study was to achieve a general understanding of savings as a function of refrigerator label ratings, occupant effects, indoor and compartment temperatures, and characteristics (such as size, defrost features, and vintage). The data collected in 1997 was used to construct models of refrigerator energy consumption as a function of key refrigerator and occupant characteristics.

Pratt, R.G.; Miller, J.D.

1998-09-01T23:59:59.000Z

303

MagLab - Dilution Refrigerator  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

in science. Using a condensationevaporation cycle not unlike that of a kitchen refrigerator, a dil fridge takes 4.2 K liquid helium way down to 1.5 K. The animation below...

304

Analysis of simultaneous cooling and heating in supermarket refrigeration systems.  

E-Print Network [OSTI]

?? In this master thesis project, conventional supermarket refrigeration systems using R404A are compared with refrigeration system solutions using natural refrigerants such as carbon dioxide… (more)

Marigny, Johan

2011-01-01T23:59:59.000Z

305

An experimental study of waste heat recovery from a residential refrigerator  

SciTech Connect (OSTI)

This paper describes the design, construction, and testing of an integrated heat recovery system which has been designed both to enhance the performance of a residential refrigerator and simultaneously to provide preheated water for an electric hot water heater. A commercial, indirect-heated hot water tank was retrofitted with suitable tubing to permit it to serve as a water cooled condenser for a residential refrigerator. This condenser operates in parallel with the air-cooled condenser tubing of the refrigerator so that either one or the other is active when the refrigerator is running. The refrigerator was housed in a controlled-environment chamber, and it was instrumented so that its performance could be monitored carefully in conjunction with the water pre-heating system. The system has been tested under a variety of hot water usage protocols, and the resulting data set has provided significantly insight into issues associated with commercial implementation of the concept. For the case of no water usage, the system was able to provide a 35 C temperature rise in the storage tank after about 100 hours of continuous operation, with no detectable deterioration of the refrigerator performance. Preliminary tests with simulations of high water usage, low water usage, and family water usage indicate a possible 18--20% energy savings for hot water over a long period of operation. Although the economic viability for such a system in a residential environment would appear to be sub-marginal, the potential for such a system associated with commercial-scale refrigeration clearly warrants further study, particularly for climates for which air conditioning heat rejection is highly seasonal.

Clark, R.A.; Smith, R.N.; Jensen, M.K. [Rensselaer Polytechnic Inst., Troy, NY (United States)

1996-12-31T23:59:59.000Z

306

Building Technologies Office: HVAC and Water Heater Field Tests Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

HVAC and Water Heater HVAC and Water Heater Field Tests Research Project to someone by E-mail Share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Facebook Tweet about Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Twitter Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Google Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Delicious Rank Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Digg Find More places to share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research

307

Heat Pump Water Heater using Solid-State Energy Converters |...  

Energy Savers [EERE]

Heat Pump Water Heater using Solid-State Energy Converters Heat Pump Water Heater using Solid-State Energy Converters Sheetak will work on developing a full scale prototype of its...

308

Design, Stress Analysis and Operating Experience in Feedwater Heaters  

E-Print Network [OSTI]

The performance of feedwater heaters has a direct bearing on the thermal efficiency of the plant. A typical feedwater heater may have three distinct regions of heat transfer, namely desuperheating, condensing and subcooling zones. The design...

Singh, K. P.; Libs, T.

1980-01-01T23:59:59.000Z

309

TVA Partner Utilities- Energy Right Water Heater Program  

Broader source: Energy.gov [DOE]

The TVA energy right Water Heater Plan promotes the installation of high efficiency water heaters in homes and small businesses. TVA provides a $50 incentive to local power companies for each...

310

TVA Partner Utilities- Energy Right Water Heater Program  

Broader source: Energy.gov [DOE]

The Tennessee Valley Authority (TVA) energy right Water Heater Plan promotes the installation of high efficiency water heaters in homes and small businesses. TVA provides a $50 incentive to local...

311

Making Water Heaters More Efficient | GE Global Research  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Water Heaters More Efficient Making Water Heaters More Efficient Jigar Shah 2013.11.13 As children, many of us grow up wanting to make some sort of lasting positive impact on...

312

NREL Evaluates Performance of Heat Pump Water Heaters (Fact Sheet)  

SciTech Connect (OSTI)

NREL evaluates energy savings potential of heat pump water heaters in homes throughout all U.S. climate zones.

Not Available

2012-02-01T23:59:59.000Z

313

Analysis of heat recovery in supermarket refrigeration system using carbon dioxide as refrigerant.  

E-Print Network [OSTI]

?? The aim of this study is to investigate the heat recovery potential in supermarket refrigeration systems using CO2 as refrigerants. The theoretical control strategy… (more)

Abdi, Amir

2014-01-01T23:59:59.000Z

314

GEA Refrigeration Technologies / GEA Refrigeration Germany GmbH Wolfgang Dietrich / Dr. Ole Fredrich  

E-Print Network [OSTI]

GEA Refrigeration Technologies / GEA Refrigeration Germany GmbH Wolfgang Dietrich / Dr. Ole Technologies3 Achema 2012 // heat pumps using ammonia Industrial demand on heat in Germany Heatdemandin

Oak Ridge National Laboratory

315

Covered Product Category: Commercial Gas Water Heaters  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including commercial gas water heaters, which are covered by the ENERGY STAR® program. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

316

Retailers and Distributors CEC-400-2012-FS-005-En Updated 3/6/2012  

E-Print Network [OSTI]

· Plumbingfittingsandfixtures · Poolandspaequipment · Externalpowersupplies · Refrigerators,refrigerator-freezers, andfreezers

317

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

E-Print Network [OSTI]

Diagram 1: A Typical Tank Water Heater Source: http://to-unit comparisons of tank versus tankless water heaters.Energy Use MJ/(unit*year) Tank Tankless MJ/(unit*year) Tank

Lu, Alison

2011-01-01T23:59:59.000Z

318

Analysis of Minimum Efficiency Standards and Rebate Incentive Programs for Domestic Refrigerators in the Pacific Northwest.  

SciTech Connect (OSTI)

Refrigerator-freezers (R/Fs) and freezers (FRs) account for 16% of the electricity consumed in the residential sector of the Bonneville Power Administration (BPA) forecast region (Oregon, Washington, Idaho and Western Montana). After space and water heating, R/Fs are the largest residential electrical end-use. There is great potential for reducing electricity consumption in a cost-effective manner through the purchase and use of more energy-efficient R/Fs and FRs. For example, if every household in the BPA region had the best R/F model now mass-produced, the electricity savings would be about 5 billion kWh/yr, approximately the power supplied annually by 1000 MW of nuclear or coal-fired generating capacity. The Northwest Power Planning Council (NPPC) and BPA recognize the savings potential from efficient R/Fs and FRs as well as the barriers to their use. In the 1983 regional power plan, the Council directed BPA to develop and implement incentive and promotion programs for efficient appliances. The NPPC also called for the evaluation of minimum efficiency standards for appliances sold in the region. In response to this directive, the Office of Conservation in BPA funded an evaluation of both rebate incentive programs and minimum efficiency standards for R/Fs and FRs. The results are presented in this report.

Geller, Howard S.

1985-11-01T23:59:59.000Z

319

Field Demonstration of High Efficiency Ultra-Low-Temperature Laboratory Freezers  

Broader source: Energy.gov [DOE]

Ultra-low temperature laboratory freezers (ULTs) are some of the most energy-intensive pieces of equipment in a scientific research laboratory, yet there are several barriers to user acceptance and adoption of high-efficiency ULTs. One significant barrier is a relative lack of information on ULT efficiency to help purchasers make informed decisions with respect to efficient products.

320

Fort Meade demonstration test LEDS in freezer rooms, fiber optics in display cases  

SciTech Connect (OSTI)

Demonstration projects at Fort George G. Meade, MD, substituted LED lighting for incandescent bulbs in commisary wal-in freezers and fiber optic lighting in reach-in display cases. The goal was to reduce energy consumption and the results were positive. Journal article published in Public Works Digest

Parker, Steven; Parker, Graham B.

2008-10-25T23:59:59.000Z

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

China Refrigerator Information Label: Specification Development and Potential Impact  

E-Print Network [OSTI]

Household Refrigerator Market and Energy Conservation Regulations in Japan.Household Refrigerator Market and Energy Conservation Regulations in Japan

Fridley, David

2008-01-01T23:59:59.000Z

322

An Overview of the New Residential Water Heater Efficiency Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

An Overview of the New Residential Water Heater Efficiency Standards An Overview of the New Residential Water Heater Efficiency Standards Speaker(s): Alex Lekov Date: April 26, 2010 - 12:00pm Location: 90-3122 DOE issued new standards for residential water heaters last month that will save an estimated 2.6 quads of energy over 30 years. For most product sizes sold, the new standards can be met with modest changes, such as adding more insulation to today's conventional tank-style water heaters. For the most common size electric water heater (50 gallons), the standards will save 4 percent, while for the most common size gas water heater (40 gallons), the new standards will save 3 percent. However, for the biggest products (those with over 55 gallons in storage capacity, which is about 9% and 4% of the electric and gas storage water heater markets, respectively), the new

323

TVA Partner Utilities - Energy Right' Water Heater Program | Department of  

Broader source: Energy.gov (indexed) [DOE]

Right' Water Heater Program Right&#039; Water Heater Program TVA Partner Utilities - Energy Right' Water Heater Program < Back Eligibility Installer/Contractor Residential Utility Savings Category Appliances & Electronics Water Heating Maximum Rebate Member utility water heater rebate programs can range from $25 to total cost. Program Info State Mississippi Program Type Utility Rebate Program Rebate Amount Energy Efficient Water Heater: $50 from TVA Provider Tennessee Valley Authority The TVA energy right Water Heater Plan promotes the installation of high efficiency water heaters in homes and small businesses. TVA provides a $50 incentive to local power companies for each installation. Power Companies may pass these incentives on to customers. Customers should contact their local power company to see what programs are

324

Burbank Water and Power - Solar Water Heater Rebate Program (California) |  

Broader source: Energy.gov (indexed) [DOE]

Burbank Water and Power - Solar Water Heater Rebate Program Burbank Water and Power - Solar Water Heater Rebate Program (California) Burbank Water and Power - Solar Water Heater Rebate Program (California) < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State California Program Type Utility Rebate Program Rebate Amount $1,500 Provider Rebates Burbank Water and Power is providing incentives for the purchase of solar water heaters. Incentives are only available to residential customers with electric water heaters. There is a limit of one solar water heater per year per property. Applicants must provide access to their residence for a pre-inspection to verify the existing use of an electric water heater. Customers must comply with all code and permit requirements. More

325

Advanced refinery process heater. Annual report, October 1983-September 1984  

SciTech Connect (OSTI)

Activity during the first year of this project has focused on the conceptual design of the prototype heater and on the development of a custom-designed Pyrocore ceramic fiber burner for the heater. Three different concepts for the prototype heater have been produced, one of them modeled after a vertical cylindrical design and the other two resembling box-type heaters. All three concepts take advantage of the Pyrocore burner's flameless characteristic to make the heater more compact. Concerning the development of the burners, two different geometries were considered. Subscale prototypes of each type of burner were fabricated and tested. The more successful burners used actively-cooled edges to maintain the integrity of the gas-tight seals. Work on this project in the second year will include the design and fabrication of the 10 MMBtu/hr prototype heater, using the most feasible heater and burner designs developed during the first year.

Schreiber, R.J.; Gotterba, J.A.; Minden, A.C.

1984-10-01T23:59:59.000Z

326

Thermoelectric refrigerator having improved temperature stabilization means  

DOE Patents [OSTI]

A control system for thermoelectric refrigerators is disclosed. The thermoelectric refrigerator includes at least one thermoelectric element that undergoes a first order change at a predetermined critical temperature. The element functions as a thermoelectric refrigerator element above the critical temperature, but discontinuously ceases to function as a thermoelectric refrigerator element below the critical temperature. One example of such an arrangement includes thermoelectric refrigerator elements which are superconductors. The transition temperature of one of the superconductor elements is selected as the temperature control point of the refrigerator. When the refrigerator attempts to cool below the point, the metals become superconductors losing their ability to perform as a thermoelectric refrigerator. An extremely accurate, first-order control is realized.

Falco, Charles M. (Woodridge, IL)

1982-01-01T23:59:59.000Z

327

International Refrigeration: Order (2012-CE-1510)  

Broader source: Energy.gov [DOE]

DOE ordered International Refrigeration Products to pay an $8,000 civil penalty after finding International Refrigeration had failed to certify that certain room air conditioners comply with the applicable energy conservation standard.

328

Condensing Hybrid Water Heater Monitoring Field Evaluation  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Condensing Hybrid Water Heater Condensing Hybrid Water Heater Monitoring Field Evaluation Jeff Maguire, Lieko Earle, and Chuck Booten National Renewable Energy Laboratory C.E. Hancock Mountain Energy Partnership Produced under direction of the Sacramento Municipal Utilities District by the National Renewable Energy Laboratory (NREL) under Interagency Agreement CRD-05-168 and Task No WR49.3000. Technical Report NREL/TP-5500-52234 October 2011 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308

329

AWSWAH - the heat pipe solar water heater  

SciTech Connect (OSTI)

An all weather heat pipe solar water heater (AWSWAH) comprising a collector of 4 m/sup 2/ (43 ft/sup 2/) and a low profile water tank of 160 liters (42 gal.) was developed. A single heat pipe consisting of 30 risers and two manifolds in the evaporator and a spiral condenser was incorporated into the AWSWAH. Condensate metering was done by synthetic fiber wicks. The AWSWAH was tested alongside two conventional solar water heaters of identical dimensions, an open loop system and a closed loop system. It was found that the AWSWAH was an average of 50% more effective than the open system in the temperature range 30-90 /sup 0/C (86-194 /sup 0/F). The closed loop system was the least efficient of the three systems.

Akyurt, M.

1986-01-01T23:59:59.000Z

330

Synthesis of Cascade Refrigeration and Liquefaction Systems  

Science Journals Connector (OSTI)

Synthesis of Cascade Refrigeration and Liquefaction Systems ... Current Status and Perspectives of Liquefied Natural Gas (LNG) Plant Design ...

Francisco J. Barnés; C. Judson King

1974-10-01T23:59:59.000Z

331

Interactive Synthesis of Cascade Refrigeration Systems  

Science Journals Connector (OSTI)

Interactive Synthesis of Cascade Refrigeration Systems ... Current Status and Perspectives of Liquefied Natural Gas (LNG) Plant Design ...

Wai Biu Cheng; Richard S. H. Mah

1980-07-01T23:59:59.000Z

332

Cryostat including heater to heat a target  

DOE Patents [OSTI]

A cryostat is provided which comprises a vacuum vessel; a target disposed within the vacuum vessel; a heat sink disposed within the vacuum vessel for absorbing heat from the detector; a cooling mechanism for cooling the heat sink; a cryoabsorption mechanism for cryoabsorbing residual gas within the vacuum vessel; and a heater for maintaining the target above a temperature at which the residual gas is cryoabsorbed in the course of cryoabsorption of the residual gas by the cryoabsorption mechanism. 2 figs.

Pehl, R.H.; Madden, N.W.; Malone, D.F.

1990-09-11T23:59:59.000Z

333

Wheel-type magnetic refrigerator  

DOE Patents [OSTI]

The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load. 7 figs.

Barclay, J.A.

1983-10-11T23:59:59.000Z

334

Covered Product Category: Residential Refrigerators  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance across a variety of product categories, including residential refrigerators, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

335

Development of Environmentally Benign Heat Pump Water Heaters for the US Market  

SciTech Connect (OSTI)

Improving energy efficiency in water heating applications is important to the nation's energy strategies. Water heating in residential and commercial buildings accounts for about 10% of U.S. buildings energy consumption. Heat pump water heating (HPWH) technology is a significant breakthrough in energy efficiency, as an alternative to electric resistance water heating. Heat pump technology has shown acceptable payback period with proper incentives and successful market penetration is emerging. However, current HPWH require the use of refrigerants with high Global Warming Potential (GWP). Furthermore, current system designs depend greatly on the backup resistance heaters when the ambient temperature is below freezing or when hot water demand increases. Finally, the performance of current HPWH technology degrades greatly as the water set point temperature exceeds 330 K. This paper presents the potential for carbon dioxide, CO2, as a natural, environmentally benign alternative refrigerant for HPWH technology. In this paper, we first describe the system design, implications and opportunities of operating a transcritical cycle. Next, a prototype CO2 HPWH design featuring flexible component evaluation capability is described. The experimental setup and results are then illustrated followed by a brief discussion on the measured system performance. The paper ends with conclusions and recommendations for the development of CO2 heat pump water heating technology suitable for the U.S. market.

Abdelaziz, Omar [ORNL] [ORNL; Wang, Kai [ORNL] [ORNL; Vineyard, Edward Allan [ORNL] [ORNL; Roetker, Jack [General Electric - Appliance Park] [General Electric - Appliance Park

2012-01-01T23:59:59.000Z

336

Aiken Electric Cooperative Inc - Residential Water Heater Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

Aiken Electric Cooperative Inc - Residential Water Heater Rebate Aiken Electric Cooperative Inc - Residential Water Heater Rebate Program Aiken Electric Cooperative Inc - Residential Water Heater Rebate Program < Back Eligibility Residential Savings Category Appliances & Electronics Water Heating Program Info State South Carolina Program Type Utility Rebate Program Rebate Amount Free high efficiency water Heater; $200 installation fee Water heater and timer with normal installation: $2.50 credit for 10 years Timer only: $200 cash payment and $2.50 credit for 10 years New construction contract home: $250 Provider Aiken Electric Cooperative Aiken Electric Cooperative offers residential members rebates for installing high-efficiency electric water heaters and/or timers in their homes. Customers have four rebate options:

337

Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program  

Broader source: Energy.gov (indexed) [DOE]

Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program (Georgia) Coweta-Fayette EMC - Residential Solar Water Heater Rebate Program (Georgia) < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Georgia Program Type Utility Rebate Program Rebate Amount Existing Homes Solar Water Heater: $750 New Homes Solar Water Heater: $1,250 - $1,500 Provider Coweta-Fayette Electric Membership Corporation Coweta-Fayette Electric Membership Corporation (EMC) provides electric and natural gas service to 58,000 customers in Georgia's Coweta, Fayette, Meriwether, Heard, Troop and Fulton counties. Currently, Coweta-Fayette EMC offers rebates on solar water heaters from $750 up to $1,500 as part of the Touchstone Energy Home Program. Solar

338

The Trials and Tribulations of Testing Water Heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The Trials and Tribulations of Testing Water Heaters The Trials and Tribulations of Testing Water Heaters Speaker(s): James Lutz Date: August 14, 2001 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Julie Osborn During our work on efficiency standards for electric water heaters, we discovered significant discrepancies between the rated and tested efficiencies of the highest rated electric resistance water heaters. For high efficiency electric resistance water heaters with an Energy Factor above .92, the heat losses are so small that minor flaws in the tank or obscure problems in the test procedure become more apparent. This seminar reports on our investigation into the causes of inconsistent results obtained during testing of high efficiency electric resistance water heaters at different test labs. We discovered some reasons for the

339

Linn County Rural Electric Cooperative - Solar Water Heater Rebate Program  

Broader source: Energy.gov (indexed) [DOE]

Linn County Rural Electric Cooperative - Solar Water Heater Rebate Linn County Rural Electric Cooperative - Solar Water Heater Rebate Program Linn County Rural Electric Cooperative - Solar Water Heater Rebate Program < Back Eligibility Agricultural Commercial Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Iowa Program Type Utility Rebate Program Rebate Amount $500 Provider Linn County Rural Electric Cooperative Association Linn County Rural Electric Cooperative Association (Linn County RECA) is a member-owned cooperative. To encourage energy efficiency, Linn County offers a number of rebates to commercial, residential, and agricultural customers. Owners of both new construction and existing buildings are eligible for a $500 rebate for solar water heaters. The water heaters must have an auxiliary tank of at least 40 gallons and the solar water heater

340

Rock Hill Utilities - Water Heater and Heat Pump Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

Rock Hill Utilities - Water Heater and Heat Pump Rebate Program Rock Hill Utilities - Water Heater and Heat Pump Rebate Program Rock Hill Utilities - Water Heater and Heat Pump Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heat Pumps Appliances & Electronics Water Heating Program Info State South Carolina Program Type Utility Rebate Program Rebate Amount Water Heater: up to $275 Heat Pump Replacement: $400 Provider Rock Hill Utilities Through the SmartChoice program, Rock Hill Utilities offers rebates for water heater and heat pump replacements. Information on financing for heat pumps can also be found on the web site listed above. If both the water heater and heat pump are purchased then the customer may qualify for the Great Rate program. The Great Rate program will add a 25% discount to a

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Multi-step heater deployment in a subsurface formation  

DOE Patents [OSTI]

A method for installing a horizontal or inclined subsurface heater includes placing a heating section of a heater in a horizontal or inclined section of a wellbore with an installation tool. The tool is uncoupled from the heating section. A lead in section is mechanically and electrically coupled to the heating section of the heater. The lead-in section is located in an angled or vertical section of the wellbore.

Mason, Stanley Leroy (Allen, TX)

2012-04-03T23:59:59.000Z

342

Insulated conductor temperature limited heater for subsurface heating coupled in a three-phase WYE configuration  

DOE Patents [OSTI]

A heating system for a subsurface formation is described. The heating system includes a first heater, a second heater, and a third heater placed in an opening in the subsurface formation. Each heater includes: an electrical conductor; an insulation layer at least partially surrounding the electrical conductor; and an electrically conductive sheath at least partially surrounding the insulation layer. The electrical conductor is electrically coupled to the sheath at a lower end portion of the heater. The lower end portion is the portion of the heater distal from a surface of the opening. The first heater, the second heater, and the third heater are electrically coupled at the lower end portions of the heaters. The first heater, the second heater, and the third heater are configured to be electrically coupled in a three-phase wye configuration.

Vinegar, Harold J. (Bellaire, TX); Sandberg, Chester Ledlie (Palo Alto, CA)

2010-11-09T23:59:59.000Z

343

Advanced refinery process heater. Final report, (October 1983-September 1988)  

SciTech Connect (OSTI)

A prototype refinery process heater was designed, built and successfully tested, demonstrating the improvements available to heater design through the use of Zone-Controlled Pyrocore radiant gas burners. The 10 MMBtu/hr rated heater released 17 ppm NOx (corrected to 3% oxygen) under full load operation, the lowest NOx emissions technically and commercially achieved in this type of equipment without the use of post-combustion flue-gas processing. Operating with 400F combustion air preheat and a 500F process fluid outlet temperature, the heater achieved overall thermal efficiencies of 92.8% on a LHV basis due in part to the significantly improved performance of the radiant heat exchange section. The radiant burners used in the heater have been proven in performance and reliability, and have also been shown to be applicable to both new heater designs and retrofits into existing heaters. The improved radiant performance of the heater and the use of 'flameless' radiant burners eliminates tube burn-out failures in both the radiant and convective tube coils, further improving the reliability of equipment based on this design. Three separate U.S. Patents have been issued covering the heater design and the use of Zone-Controlled Pyrocore burners in this application.

Minden, A.C.; Buckley, G.G.

1989-04-01T23:59:59.000Z

344

NREL Develops Heat Pump Water Heater Simulation Model (Fact Sheet)  

SciTech Connect (OSTI)

A new simulation model helps researchers evaluate real-world impacts of heat pump water heaters in U.S. homes.

Hudon, K.

2012-05-01T23:59:59.000Z

345

Heat Pump Water Heaters and American Homes: A Good Fit?  

E-Print Network [OSTI]

as conventional electric resistance water heaters, with thetwo technologies: (1) an electric resistance storage watertransfers heat from the electric resistance element to the

Franco, Victor

2011-01-01T23:59:59.000Z

346

Slurry fired heater cold-flow modelling  

SciTech Connect (OSTI)

This report summarizes the experimental and theoretical work leading to the scale-up of the SRC-I Demonstration Plant slurry fired heater. The scale-up involved a theoretical model using empirical relations in the derivation, and employed variables such as flow conditions, liquid viscosity, and slug frequency. Such variables have been shown to affect the heat transfer characteristics ofthe system. The model assumes that, if all other variables remain constant, the heat transfer coefficient can be scaled up proportional to D/sup -2/3/ (D = inside diameter of the fired heater tube). All flow conditions, liquid viscosities, and pipe inclinations relevant to the demonstration plant have indicated a slug flow regime in the slurry fired heater. The annular and stratified flow regimes should be avoided to minimize the potential for excessive pipe erosion and to decrease temperature gradients along the pipe cross section leading to coking and thermal stresses, respectively. Cold-flow studies in 3- and 6.75-in.-inside-diameter (ID) pipes were conducted to determine the effect of scale-up on flow regime, slug frequency, and slug dimensions. The developed model assumes that conduction heat transfer occurs through the liquid film surrounding the gas slug and laminar convective heat transfer to the liquid slug. A weighted average of these two heat transfer mechanisms gives a value for the average pipe heat transfer coefficient. The cold-flow work showed a decrease in the observed slug frequency between the 3- and 6.75-ID pipes. Data on the ratio of gas to liquid slug length in the 6.75-in. pipe are not yet complete, but are expected to yield generally lower values than those obtained in the 3-in. pipe; this will probably affect the scale-up to demonstration plant conditions. 5 references, 15 figures, 7 tables.

Moujaes, S.F.

1983-07-01T23:59:59.000Z

347

Certification reporting forms  

SciTech Connect (OSTI)

The required information and formats for the certification report including the cover sheet, compliance statement, and body of the report are given in this document. The body of the reports is different for each product. There are no product-to-product differences in the forms of the other parts of the reports. The products covered in this document include: furnaces, water heaters, refrigerator-freezers, central air conditioners, room air conditioners, and freezers.

Not Available

1981-02-18T23:59:59.000Z

348

Quantum-enhanced absorption refrigerators  

E-Print Network [OSTI]

Thermodynamics is a branch of science blessed by an unparalleled combination of generality of scope and formal simplicity. Based on few natural assumptions together with the four laws, it sets the boundaries between possible and impossible in macroscopic aggregates of matter. This triggered groundbreaking achievements in physics, chemistry and engineering over the last two centuries. Close analogues of those fundamental laws are now being established at the level of individual quantum systems, thus placing limits on the operation of quantum-mechanical devices. Here we study quantum absorption refrigerators, which are driven by heat rather than external work. We establish thermodynamic performance bounds for these machines and investigate their quantum origin. We also show how those bounds may be pushed beyond what is classically achievable, by suitably tailoring the environmental fluctuations via quantum reservoir engineering techniques. Such superefficient quantum-enhanced cooling realises a promising step towards the technological exploitation of autonomous quantum refrigerators.

Luis A. Correa; José P. Palao; Daniel Alonso; Gerardo Adesso

2013-08-19T23:59:59.000Z

349

HFC supermarket refrigeration demonstration. Phases 1 and 2  

SciTech Connect (OSTI)

The HFC Supermarket Refrigeration Demonstration tested and evaluated HFC refrigerants in a new Shop `n Save supermarket in Glens Falls, New York. This project included laboratory testing of HFC refrigerants for medium- and low-temperature application, the design of a supermarket refrigeration system to accommodate the new refrigerants, installation, start-up, and field monitoring.

Borhanian, H.; Rafuse, L.

1996-04-01T23:59:59.000Z

350

Suction muffler for refrigeration compressor  

DOE Patents [OSTI]

A hermetic refrigeration compressor includes a suction muffler formed from two pieces of plastic material mounted on the cylinder housing. One piece is cylindrical in shape with an end wall having an aperture for receiving a suction tube connected to the cylinder head. The other piece fits over and covers the other end of the cylindrical piece, and includes a flaring entrance horn which extends toward the return line on the sidewall of the compressor shell. 5 figs.

Nelson, R.T.; Middleton, M.G.

1983-01-25T23:59:59.000Z

351

Solar sorption refrigeration in Africa  

Science Journals Connector (OSTI)

Abstract Solar sorption refrigeration technologies are regarded as a promising way to meet the growing refrigeration needs in Africa, for thermal comfort, foods and crops, vaccines and medicines conservation. Sorption technologies projects and studies have been reported in Africa since the late 1970s. This paper describes the most representative reported research activities and projects in various African climatic conditions. An emphasis is put on demonstrative plants involving absorption, adsorption or desiccant cooling applications. From this overview, it appears that a lot of achievements have been made, though applications are mainly focused on small-size cold boxes for foods and vaccines preservation; no direct building air conditioning based on adsorption or absorption has been reported. Mediterranean countries seems to offer the best weather conditions for solar sorption refrigeration applications and plenty of related activities could be identified in these countries. A more adequate design for each of other climatic zones in Africa may then be relevant. As anywhere, the high cost of these technologies remains the main the biggest brake to their diffusion in Africa.

Kokouvi Edem N’Tsoukpoe; Daniel Yamegueu; Justin Bassole

2014-01-01T23:59:59.000Z

352

Cowlitz County PUD - Residential Energy Efficient Appliance Rebate Program  

Broader source: Energy.gov (indexed) [DOE]

Cowlitz County PUD - Residential Energy Efficient Appliance Rebate Cowlitz County PUD - Residential Energy Efficient Appliance Rebate Program Cowlitz County PUD - Residential Energy Efficient Appliance Rebate Program < Back Eligibility Residential Savings Category Appliances & Electronics Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount Refrigerator/Freezer: $25 Refrigerator/Freezer Recycling: $30 Clothes Washer: $30 - $70 Water Heater: $25 - $70 Provider Cowlitz County Public Utility District Cowlitz County PUD offers the EnergySHARE Plus appliance rebate program to its residential customers. Rebates are offered for Energy Star clothes washers, refrigerators and freezers (including the proper recycling of old units), and energy efficient water heaters. Rebates range from $25 - $70.

353

Georgia Power- Residential Solar and Heat Pump Water Heater Rebate (Georgia)  

Broader source: Energy.gov [DOE]

Georgia Power customers may be eligible for rebates up to $250 each toward the installation costs of a 50 gallon or greater solar water heater or heat pump water heater. The solar water heater or...

354

ELECTRICAL HEATERS FOR THERMO-MECHANICAL TESTS AT THE STRIPA MINE  

E-Print Network [OSTI]

5.5 Dewatering Pump 6. ELECTRICAL HEATER CONTROL SYSTEMS 6.1water influx ABSTRACT Electrical heaters were installed atcanister) which houses the electrical heater elements; c. d.

Burleigh, R.H.

2010-01-01T23:59:59.000Z

355

Solar pool heaters: The simplest use of active solar energy  

SciTech Connect (OSTI)

Solar pool heating is the most attractive solar water heating market today, because most pool heaters pay back their purchase price in lower utility bills in two to three years. This article describes why solar pool heaters are popular and their design, operation, and return on investment. 1 fig.

Sheinkopf, K. [Florida Solar Energy Center, Cocoa, FL (United States)

1997-11-01T23:59:59.000Z

356

Solid-Vapor Sorption Refrigeration Systems  

E-Print Network [OSTI]

adsorbents in heat pump cycles: 1. A high usable refrigerant mass per unit mass of adsorbent. 2. A high energy of adsorption and desorption. 3. Heat flows and composition changes occur at constant temperature. The advantages of complex compounds... 2. Useable refrigerant densities. Summarizing, complex compound exhibit inherent characteristics which make them ideal adsorbents in heat pump cycles: 1. A high usable refrigerant mass per unit mass of adsorbent. 2. A high energy of adsorption...

Graebel, W.; Rockenfeller, U.; Kirol, L.

357

Analysis of Minimum Efficiency Standards and Rebate Incentive Programs for Domestic Refrigerators in the Pacific Northwest, Executive Summary.  

SciTech Connect (OSTI)

Refrigerator-freezers (R/Fs) and freezers (FRs) account for 16% of the electricity consumed in the residential sector of the Bonneville Power Administration (BPA) forecast region (Oregon, Washington, Idaho and Western Montana). After space and water heating, R/Fs are the largest residential electrical end-use. The Northwest Power Planning Council (NPPC) and BPA recognize the savings potential from efficient R/Fs and FRs as well as the barriers to their use. In the 1983 regional power plan, the Council directed BPA to develop and implement incentive and promotion programs for efficient appliances. The NPPC also called for the evaluation of minimum efficiency standards for appliances sold in the region. In response to this directive, the Office of Conservation in BPA funded an evaluation of both rebate incentive programs and minimum efficiency standards for R/Fs and FRs. The results are presented in this report. The energy savings potential and economic feasibility of rebate programs and efficiency standards are the primary issues considered.

Geller, Howard S.

1986-01-01T23:59:59.000Z

358

Tri-County Electric Cooperative - Energy Efficient Water Heater Rebate  

Broader source: Energy.gov (indexed) [DOE]

Tri-County Electric Cooperative - Energy Efficient Water Heater Tri-County Electric Cooperative - Energy Efficient Water Heater Rebate Program Tri-County Electric Cooperative - Energy Efficient Water Heater Rebate Program < Back Eligibility Commercial Residential Savings Category Appliances & Electronics Water Heating Program Info State Texas Program Type Utility Rebate Program Rebate Amount $75 Provider Tri-County Electric Cooperative Tri-County Electric Cooperative offers a $75 rebate on the purchase of energy-efficient electric water heaters. The rebate is valid for new or replacement units which have an Energy Factor Rating of 0.90 or higher. The minimum tank size is 40 gallons, with a minimum 4,500 watt heating element. For validation purposes, a copy of the sales or installation receipt must accompany the [http://www.tcectexas.com/Forms/water%20heater%20rebate%20form.pdf

359

Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate  

Broader source: Energy.gov (indexed) [DOE]

Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate Program Clay Electric Cooperative, Inc - Energy Smart Solar Water Heater Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Maximum Rebate $600 Program Info State Florida Program Type Utility Rebate Program Rebate Amount 0.01 per BTU output Provider Clay Electric Co-op Clay Electric Cooperative (CEC) provides a rebate of $0.01 per BTU output to its residential members when they purchase qualified solar water heaters. This rebate is capped at 60,000 BTUs per system, or $600. Eligible solar water heaters can be either passive or active systems. The proposed solar system must meet Florida Solar Energy Center (FSEC) specifications and be installed by a contractor certified to install solar water heating

360

Cost of Increased Energy Efficiency for Residential Water Heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Cost of Increased Energy Efficiency for Residential Water Heaters Cost of Increased Energy Efficiency for Residential Water Heaters Speaker(s): Alex Lekov Date: March 22, 2001 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Julie Osborn This presentation describes the analysis of the costs of increased energy efficiency for residential water heaters. Here, we focus on the cost and efficiency data for electric and gas-fired water heaters. This data formed the basis of the Technical Support Document for the Department of Energy's (DOE) Final Rule on Water Heaters. The engineering analysis uses computer simulation models to investigate the efficiency improvements due to design options and combinations thereof. The analysis covers four polyurethane foam insulation types based on non-ozone-depleting substances as blowing

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Tankless Demand Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Demand Water Heater Basics Demand Water Heater Basics Tankless Demand Water Heater Basics August 19, 2013 - 2:57pm Addthis Illustration of an electric demand water heater. At the top of the image, the heating unit is shown. Cold water flows in one end of a pipe, flows through and around several curved pipes over the heating elements, and out the other end as hot water. Beneath the heating unit, a typical sink setup is shown. The sink has two pipes coming out the bottom, one for the hot water line and one for the cold water line. Both pipes lead to the heating unit, which is installed in close proximity to the area of hot water use, and is connected to a power source (110 or 220 volts). Demand (tankless or instantaneous) water heaters have heating devices that are activated by the flow of water, so they provide hot water only as

362

Tankless Demand Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Tankless Demand Water Heater Basics Tankless Demand Water Heater Basics Tankless Demand Water Heater Basics August 19, 2013 - 2:57pm Addthis Illustration of an electric demand water heater. At the top of the image, the heating unit is shown. Cold water flows in one end of a pipe, flows through and around several curved pipes over the heating elements, and out the other end as hot water. Beneath the heating unit, a typical sink setup is shown. The sink has two pipes coming out the bottom, one for the hot water line and one for the cold water line. Both pipes lead to the heating unit, which is installed in close proximity to the area of hot water use, and is connected to a power source (110 or 220 volts). Demand (tankless or instantaneous) water heaters have heating devices that are activated by the flow of water, so they provide hot water only as

363

Clark Public Utilities - Solar Water Heater Rebate | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Clark Public Utilities - Solar Water Heater Rebate Clark Public Utilities - Solar Water Heater Rebate Clark Public Utilities - Solar Water Heater Rebate < Back Eligibility Commercial Residential Savings Category Heating & Cooling Solar Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount $500 Provider Clark PUD Clark Public Utilities offers a rebate of $500 to customers who install a solar water heating system. Customers must own the residence or business where the solar water heating system is installed and must have an electric water heater. In addition, Clark Public Utilities offers a [http://dsireusa.org/incentives/incentive.cfm?Incentive_Code=WA29F&re=1&ee=1 loan program] for eligible solar water heater equipment. For additional information, call Energy Services at (360) 992-3355.

364

List of Refrigerators Incentives | Open Energy Information  

Open Energy Info (EERE)

Refrigerators Incentives Refrigerators Incentives Jump to: navigation, search The following contains the list of 657 Refrigerators Incentives. CSV (rows 1-500) CSV (rows 501-657) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio - Commercial Custom Project Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Fed. Government Industrial Institutional Local Government Nonprofit Schools State Government Tribal Government Boilers Central Air conditioners Chillers Custom/Others pending approval Furnaces Heat pumps Heat recovery Lighting Lighting Controls/Sensors Processing and Manufacturing Equipment Refrigerators Yes AEP Ohio - Commercial Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Fed. Government Industrial

365

Natural Refrigerant (R-729) Heat Pump  

Energy Savers [EERE]

Manufactured in the U.S. 2 Problem Statement * Current commercial and industrial heat pumps - Poor coefficient of performance (COP) at low temperatures * HFC refrigerant...

366

Design of Industrial Process Refrigeration Systems  

E-Print Network [OSTI]

DESIGN OF INDUSTRIAL PROCESS REfRIGERATION SYSTEMS W.O. WITHERELL AOVENTg Technolog1st Un10n Carb1de Corporat1on South Charleston, West V1rg~n1a ABSTRACT ~hen considering electric driven refrigeration compressors, proper integration... to several canple~ processes that ut iii ze refr igerat ion systems. In IOClSt cases the design of a cOOlllex refrigeration system in isolation (i.e., without considering process integration) generallv results in non-ptilTUll refrigeration levels...

Witherell, W. D.

367

Covered Product Category: Refrigerated Beverage Vending Machines...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

vending machines are equipped with controls or software that put the lighting andor refrigeration systems into a low power state at night, on weekends, or other periods of...

368

IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems Corresponding author: P. Leblay  

E-Print Network [OSTI]

3rd IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems Corresponding author: P on the refrigerant side and louver fins on the air side. The flat tubes are grouped within a header, to use the heat exchangers with round tubes, such as charge reduction and higher heat transfer efficiency. But a reduced

Paris-Sud XI, Université de

369

Solar Water Heater Roadmap Leads Path to Market Expansion (Fact Sheet)  

SciTech Connect (OSTI)

Innovative strategy to reduce installed cost of solar water heater systems can rival conventional natural gas water heaters in the marketplace.

Not Available

2012-09-01T23:59:59.000Z

370

Evaluation of TANK water heater simulation model as embedded in HWSim  

E-Print Network [OSTI]

this scheme for operating TANK with HWSim is successful.LBNL # Evaluation of TANK water heater simulation model asCalifornia. Evaluation of TANK water heater simulation model

Lutz, Jim

2012-01-01T23:59:59.000Z

371

Review of International Methods of Test to Rate the Efficiency of Water Heaters  

E-Print Network [OSTI]

Conservation Standards for Residential Water Heaters, Direct Heating Equipment, and PoolConservation Program for Consumer Products: Test Procedures for Residential Water Heaters, Direct Heating Equipment, and Pool

Lutz, Jim

2012-01-01T23:59:59.000Z

372

Requirements for Determining Refrigerant Charge Residential Air Conditioning Measures  

E-Print Network [OSTI]

Requirements for Determining Refrigerant Charge Residential Air Conditioning Measures Improved Refrigerant Charge Purpose Component packages require in some climate zones that split system air refrigerant charge. For the performance method, the proposed design is modeled with less efficiency

373

Layer of protection analysis applied to ammonia refrigeration systems  

E-Print Network [OSTI]

Ammonia refrigeration systems are widely used in industry. Demand of these systems is expected to increase due to the advantages of ammonia as refrigerant and because ammonia is considered a green refrigerant. Therefore, it is important to evaluate...

Zuniga, Gerald Alexander

2009-05-15T23:59:59.000Z

374

Towards a Sustainable Energy Balance: Progressive Efficiency and the Return of Energy Conservation  

E-Print Network [OSTI]

data. Listings for refrigerators and freezers as of May 1,not only do some refrigerator- freezers offer thru-the-door-In the case of refrigerator-freezer labels, for example, the

Harris, Jeff

2008-01-01T23:59:59.000Z

375

Retrospective Evaluation of Appliance Price Trends  

E-Print Network [OSTI]

of Certified Refrigerators and Freezers. Business Newst(59) R 2 =.76 Refrigerators Top mounted freezer-AutodefrostRefrigerator consumption is given by adjusted volume/annual consumption, where adjusted volume, is defined as fresh food volume+1.63×freezer

Dale, Larry

2010-01-01T23:59:59.000Z

376

Towards a Sustainable Energy Balance: Progressive Efficiency and the Return of Energy Conservation  

E-Print Network [OSTI]

Data. Listings for refrigerators and freezers as of May 1,not only do some refrigerator- freezers offer thru-the-door-In the case of refrigerator-freezer labels, for example, the

Harris, Jeffrey; Diamond, Rick; Iyer, Maithili; Payne, Christopher; Blumstein, Carl; Siderius, Hans-Paul

2007-01-01T23:59:59.000Z

377

Residential Behavioral Savings: An Analysis of Principal Electricity End Uses in British Columbia  

E-Print Network [OSTI]

The study found that refrigerator and freezer temperaturekWh per year), and refrigerator and freezer (1,120 kWh perrefrigeration (refrigerators and freezers) included in the

Tiedemann, Kenneth Mr.

2013-01-01T23:59:59.000Z

378

Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in the United States  

E-Print Network [OSTI]

Historical Shipment' Compact RefrigeratorRefrigerator?Freezer Refrigerator?Freezer and Freezers NOPR National Impact Analysis Spreadsheet, USDOE (2010g)  Price Source Location By Category* Shipments Table 8.4.x Lifetime 'Historical 

Bojda, Nicholas

2011-01-01T23:59:59.000Z

379

Heat Pump Water Heater Performance in  

Broader source: Energy.gov (indexed) [DOE]

searc searc e er tra A Research Institute of the University of Central Florida FLORIDA SOLAR ENERGY CENTER - A Re h Institut of the Univ sity of Cen l Florida searc e er tra Heat Pump Water Heater Performance in Laboratory House Building America Technical Update 2013 ACI National Home Performance Conference April 29- 30 , 2013 Carlos J. Colon carlos@fsec.ucf.edu A Research Institute of the University of Central Florida FLORIDA SOLAR ENERGY CENTER - A Re h Institut of the Univ sity of Cen l Florida FLORIDA SOLAR ENERGY CENTER - A Research Institute of the University of Central Florida Hot Water Systems (HWS) Laboratory FSEC Grounds, Florida (east coast) 2009 -Present (Currently fourth testing rotation) FLORIDA SOLAR ENERGY CENTER - A Research Institute of the University of Central Florida

380

Improvement of the Performance for an Absorption Refrigeration System with Lithium bromide-water as Refrigerant by Increasing Absorption Pressure  

E-Print Network [OSTI]

Because the absorption refrigeration system uses the Lithium bromide- water solution as refrigerant, it is profitable for the environment that human beings are living since the values of ODP and GWP of the refrigerant almost are zero. However...

Xie, G.; Sheng, G.; Li, G.; Pan, S.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Federal Energy Management Program: Covered Product Category: Refrigerated  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Refrigerated Beverage Vending Machines to someone by E-mail Refrigerated Beverage Vending Machines to someone by E-mail Share Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Facebook Tweet about Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Twitter Bookmark Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Google Bookmark Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Delicious Rank Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Digg Find More places to share Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on AddThis.com...

382

DOE Opens Three Investigations into Alleged Refrigerator Efficiency...  

Broader source: Energy.gov (indexed) [DOE]

Opens Three Investigations into Alleged Refrigerator Efficiency Violations DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations April 12, 2010 - 7:27pm...

383

Corrosion aspects in indirect systems with secondary refrigerants.  

E-Print Network [OSTI]

?? Aqueous solutions of organic or inorganic salts are used as secondary refrigerants in indirect refrigeration systems to transport and transfer heat. Water is known… (more)

Ignatowicz, Monika

2008-01-01T23:59:59.000Z

384

Working Fluids Low Global Warming Potential Refrigerants | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Center. Life Cycle Climate Performance of supermarket refrigeration.
Credit: Oak Ridge National Lab Life Cycle Climate Performance of supermarket refrigeration....

385

Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active Diesel Particulate Filters Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active Diesel Particulate...

386

DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy...  

Broader source: Energy.gov (indexed) [DOE]

Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements March 16, 2010 - 4:28pm...

387

2014-04-10 Issuance: Test Procedures for Commercial Refrigeration...  

Broader source: Energy.gov (indexed) [DOE]

0 Issuance: Test Procedures for Commercial Refrigeration Equipment; Final Rule 2014-04-10 Issuance: Test Procedures for Commercial Refrigeration Equipment; Final Rule This document...

388

Chapter 7, Refrigerator Recycling Evaluation Protocol: The Uniform...  

Office of Environmental Management (EM)

of refrigerators recycled through the program EXISTINGUEC The average annual unit energy consumption of participating refrigerators PARTUSE The portion of the year the...

389

Thermodynamic Evaluation of Low-Global Warming Potential Refrigerants...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Thermodynamic Evaluation of Low-Global Warming Potential Refrigerants - 2013 Peer Review Thermodynamic Evaluation of Low-Global Warming Potential Refrigerants - 2013 Peer Review...

390

Working Fluids Low Global Warming Potential Refrigerants - 2013...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Working Fluids Low Global Warming Potential Refrigerants - 2013 Peer Review Working Fluids Low Global Warming Potential Refrigerants - 2013 Peer Review Emerging Technologies...

391

Closed cycle liquid helium refrigerators  

Science Journals Connector (OSTI)

We have developed closed cycle liquid helium refrigerators using a Joule Thomson circuit precooled by commercially available two staged Gifford Mac Mahon cryocoolers. The Joule Thomson counterflow heat exchangers are modular and have been thermo-hydraulically characterized. Fully automatic cool down and operation are achieved by two pneumatically driven by pass and expansion valves. Several apparatus have been built or are under assembly with cooling power ranging from 100 mW up to 5 Watt, for temperature ranging from 2.8 K up to 4.5 K. A trouble free operation with several warm up and cool down cycles has been proven over 7000 hours.

G. Claudet; R. Lagnier; A. Ravex

1992-01-01T23:59:59.000Z

392

Seven-effect absorption refrigeration  

DOE Patents [OSTI]

A seven-effect absorption refrigeration cycle is disclosed utilizing three absorption circuits. In addition, a heat exchanger is used for heating the generator of the low absorption circuit with heat rejected from the condenser and absorber of the medium absorption circuit. A heat exchanger is also provided for heating the generator of the medium absorption circuit with heat rejected from the condenser and absorber of the high absorption circuit. If desired, another heat exchanger can also be provided for heating the evaporator of the high absorption circuit with rejected heat from either the condenser or absorber of the low absorption circuit. 1 fig.

DeVault, R.C.; Biermann, W.J.

1989-05-09T23:59:59.000Z

393

Seven-effect absorption refrigeration  

DOE Patents [OSTI]

A seven-effect absorption refrigeration cycle is disclosed utilizing three absorption circuits. In addition, a heat exchanger is used for heating the generator of the low absorption circuit with heat rejected from the condenser and absorber of the medium absorption circuit. A heat exchanger is also provided for heating the generator of the medium absorption circuit with heat rejected from the condenser and absorber of the high absorption circuit. If desired, another heat exchanger can also be provided for heating the evaporator of the high absorption circuit with rejected heat from either the condenser or absorber of the low absorption circuit.

DeVault, Robert C. (Knoxville, TN); Biermann, Wendell J. (Fayetteville, NY)

1989-01-01T23:59:59.000Z

394

Utilization of Heat Pump Water Heaters for Load Management  

SciTech Connect (OSTI)

The Energy Conservation Standards for Residential Water Heaters require residential electric storage water heaters with volumes larger than 55 gallons to have an energy factor greater than 2.0 after April 2015. While this standard will significantly increase the energy efficiency of water heaters, large electric storage water heaters that do not use heat pump technologies may no longer be available. Since utilities utilize conventional large-volume electric storage water heaters for thermal storage in demand response programs, there is a concern that the amended standard will significantly limit demand response capacity. To this end, Oak Ridge National Laboratory partnered with the Tennessee Valley Authority to investigate the load management capability of heat pump water heaters that meet or exceed the forthcoming water heater standard. Energy consumption reduction during peak periods was successfully demonstrated, while still meeting other performance criteria. However, to minimize energy consumption, it is important to design load management strategies that consider the home s hourly hot water demand so that the homeowner has sufficient hot water.

Boudreaux, Philip R [ORNL; Jackson, Roderick K [ORNL; Munk, Jeffrey D [ORNL; Gehl, Anthony C [ORNL; Lyne, Christopher T [ORNL

2014-01-01T23:59:59.000Z

395

Modeling supermarket refrigeration energy use and demand  

SciTech Connect (OSTI)

A computer model has been developed that can predict the performance of supermarket refrigeration equipment to within 3% of field test measurements. The Supermarket Refrigeration Energy Use and Demand Model has been used to simulate currently available refrigerants R-12, R-502 and R-22, and is being further developed to address alternative refrigerants. This paper reports that the model is expected to be important in the design, selection and operation of cost-effective, high-efficiency refrigeration systems. It can profile the operation and performance of different types of compressors, condensors, refrigerants and display cases. It can also simulate the effects of store humidity and temperature on display cases; the efficiency of various floating head pressure setpoints, defrost alternatives and subcooling methods; the efficiency and amount of heat reclaim from refrigeration systems; and the influence of other variables such as store lighting and building design. It can also be used to evaluate operational strategies such as variable-speed drive or cylinder unloading for capacity control. Development of the model began in 1986 as part of a major effort, sponsored by the U.S. electric utility industry, to evaluate energy performance of then conventional single compressor and state-of-the-art multiplex refrigeration systems, and to characterize the contribution of a variety of technology enhancement features on system energy use and demand.

Blatt, M.H.; Khattar, M.K. (Electric Power Research Inst., Palo Alto, CA (US)); Walker, D.H. (Foster Miller Inc., Waltham, MA (US))

1991-07-01T23:59:59.000Z

396

The Impact of Blowing Agents on Residential Water Heater Performance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The Impact of Blowing Agents on Residential Water Heater Performance The Impact of Blowing Agents on Residential Water Heater Performance Title The Impact of Blowing Agents on Residential Water Heater Performance Publication Type Report LBNL Report Number LBNL-47352 Year of Publication 2001 Authors Lekov, Alexander B., James D. Lutz, Camilla Dunham Whitehead, and James E. McMahon Document Number LBNL-47352 Date Published January 12 Abstract The National Appliance Energy Conservation Act of 1987 (NAECA) requires the U.S. Department of Energy (DOE) to consider amendments to the energy conservation standards to increase energy efficiency in residential water heaters. A driving force affecting efficiency is the ozone-depletion regulation regarding blowing agents for insulation in all water heater fuel types. This paper presents results of cost and efficiency impacts of three potential blowing agents. Residential water heaters are typically insulated with polyurethane foam in the space between the tank and the jacket. Currently, water heater manufacturers use HCFC-141b, an ozone-depleting substance, as a blowing agent. After 2003, as a result of the Montreal Protocol (1993), manufacturers must use blowing agents that do not deplete the ozone layer. The analysis presented in this paper considers three replacement candidates, HFC-245fa, HFC-134a, and cyclopentane by comparing their efficiency and cost effectiveness when applied to water heater insulation. This analysis used computer simulation models and other analytical methods to investigate the efficiency improvements due to different design options, when alternative blowing agents are applied. The calculations were based on the DOE test procedure for residential water heaters. The analysis used average manufacturer, retailer, and installer costs to calculate the total consumer costs. Consumer operating expenses were calculated based on modeled energy consumption under test procedure conditions and U.S. average energy prices. With this information, a cost-efficiency relationship was developed to show the average manufacturer and consumer cost to achieve increased efficiency.

397

Information on the Department of Energy's analyses to determine the need for appliance efficiency standards  

SciTech Connect (OSTI)

A historical overview of three separate Department of Energy analyses performed to determine the need for appliance efficiency standards is presented. An identification of the assumptions used in each of the analyses and the conclusions reached in each analysis are covered. Standards for furnaces, water heaters, central air conditioners, refrigerators, ranges/ovens, clothes dryers, freezers, and room air conditioners are considered. (MCW)

Not Available

1981-12-23T23:59:59.000Z

398

Blue Ridge Mountain Electric Membership Corporation - Water Heater Rebate  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Blue Ridge Mountain Electric Membership Corporation - Water Heater Rebate Program Blue Ridge Mountain Electric Membership Corporation - Water Heater Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Commercial Heating & Cooling Cooling Construction Design & Remodeling Ventilation Manufacturing Heat Pumps Appliances & Electronics Water Heating Program Info State Georgia Program Type Utility Rebate Program Rebate Amount In-Home Energy Evaluation Program Windows: $500 Duct Repair: $500 Rehabilitation Work: $250 HVAC Replacement: $250/unit HVAC Tune-up: $150/unit Insulation: $500 Water Heater and Pipe Insulation: $50 Air Sealing: $500 Energy Right Program

399

Oil cooled, hermetic refrigerant compressor  

DOE Patents [OSTI]

A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler 18 and is then delivered through the shell to the top of the motor rotor 24 where most of it is flung radially outwardly within the confined space provided by the cap 50 which channels the flow of most of the oil around the top of the stator 26 and then out to a multiplicity of holes 52 to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber 58 to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole 62 also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator 68 from which the suction gas passes by a confined path in pipe 66 to the suction plenum 64 and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum 64.

English, William A. (Murrysville, PA); Young, Robert R. (Murrysville, PA)

1985-01-01T23:59:59.000Z

400

Oil cooled, hermetic refrigerant compressor  

DOE Patents [OSTI]

A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler and is then delivered through the shell to the top of the motor rotor where most of it is flung radially outwardly within the confined space provided by the cap which channels the flow of most of the oil around the top of the stator and then out to a multiplicity of holes to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator from which the suction gas passes by a confined path in pipe to the suction plenum and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum. 3 figs.

English, W.A.; Young, R.R.

1985-05-14T23:59:59.000Z

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Federal Energy Management Program: Covered Product Category: Commercial  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Commercial Refrigerators and Freezers to someone by E-mail Commercial Refrigerators and Freezers to someone by E-mail Share Federal Energy Management Program: Covered Product Category: Commercial Refrigerators and Freezers on Facebook Tweet about Federal Energy Management Program: Covered Product Category: Commercial Refrigerators and Freezers on Twitter Bookmark Federal Energy Management Program: Covered Product Category: Commercial Refrigerators and Freezers on Google Bookmark Federal Energy Management Program: Covered Product Category: Commercial Refrigerators and Freezers on Delicious Rank Federal Energy Management Program: Covered Product Category: Commercial Refrigerators and Freezers on Digg Find More places to share Federal Energy Management Program: Covered Product Category: Commercial Refrigerators and Freezers on AddThis.com...

402

EA-1138: Finding of No Significant Impact | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

of No Significant Impact Proposed Energy-Conservation Standards for Refrigerators, Refrigerator - Freezers, and Freezers Finding of No Significant Impact for amended energy...

403

Association of Home Appliance Manufacturers | Department of Energy  

Energy Savers [EERE]

summary, we discussed AHAM's written comments on DOE's Notice of Proposed Rulemaking on Test Procedures for Refrigerators, Refrigerator-Freezers, and Freezers, Docket No....

404

Fridges to fight childhood disease  

SciTech Connect (OSTI)

A solar-powered refrigerator/freezer has been installed in a medical center in Bhoorbaral, India. The installation and performance of the refrigerator/freezer are described.

Lerner, T.

1983-04-01T23:59:59.000Z

405

OCCUPATIONAL & ENVIRONMENTAL SAFETY SERVICES C:\\Documents and Settings\\sysdev\\Local Settings\\Temporary Internet Files\\OLK412\\Lab Equipment Release -New Format.doc  

E-Print Network [OSTI]

, autoclaves, centrifuges, refrigerators, freezers, incubators, BioSafety cabinets, and analytical equipment, refrigerators, freezers, incubators, etc. #12;OCCUPATIONAL & ENVIRONMENTAL SAFETY SERVICES C

Krovi, Venkat

406

Energy Data Sourcebook for the U.S. Residential Sector  

E-Print Network [OSTI]

The historical factors for refrigerators and freezers arehistorical factors are used are gas heating, room and central air- conditioning, electric and gas water-heating, refrigerators, freezers,

Wenzel, T.P.

2010-01-01T23:59:59.000Z

407

THE EFFECT OF LOCATION OF THE PREDICTED PERFORMANCE OF A HEAT PUMP WATER HEATER  

E-Print Network [OSTI]

#12;THE EFFECT OF LOCATION OF THE PREDICTED PERFORMANCE OF A HEAT PUMP WATER HEATER Laboratory testing and field testing have shown that a heat pump water heater (HPWH) uses about half the electrical energy input that an electric resistance water heater does. However, since the heat pump water heater

Oak Ridge National Laboratory

408

Space Heaters The University recognizes that individuals have different levels of comfort associated with  

E-Print Network [OSTI]

used must be currently UL (Underwriters Laboratory) approved. 4. Approved space heaters must be fan driven. Space heaters with heated coils are not permitted. 5. Space heaters must have a thermostat that shuts unit off when a certain temperature is reached. 6. Space heaters must have a tip-over shutdown

de Lijser, Peter

409

Electrical noise characteristics of a doped silicon microcantilever heater-thermometer  

E-Print Network [OSTI]

Electrical noise characteristics of a doped silicon microcantilever heater-thermometer Elise A with resistive heater-thermometers,10­13 there is a lack of published reports on the electrical noise silicon heater- thermometer cantilevers.12 However, a key difference is that doped silicon heater-thermometers

King, William P.

410

Solar Water Heaters and the Economy | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Water Heaters and the Economy Water Heaters and the Economy Solar Water Heaters and the Economy July 11, 2012 - 11:59am Addthis Ernie Tucker Editor, National Renewable Energy Laboratory These are the days of hot sun and mortgage refinance frenzy. Somehow, they've both combined in my mind to make me ponder the economics of a solar water heater. Because the sun's been beating down on our garden hose, the initial flush of water can be very hot. The warm spray reminded me of the times on camping trips when we'd bring along a portable solar shower -- essentially a black plastic bag with a tube and shower nozzle -- for bathing. While not an endless supply (perhaps 10 gallons), it was a very enjoyable luxury. Of course, it assumes that there's plenty of sunshine, but if so -- voila -- a warm and sudsy campsite clean-up is possible.

411

Grays Harbor PUD - Solar Water Heater Rebate | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Grays Harbor PUD - Solar Water Heater Rebate Grays Harbor PUD - Solar Water Heater Rebate Grays Harbor PUD - Solar Water Heater Rebate < Back Eligibility Commercial Industrial Residential Savings Category Heating & Cooling Solar Water Heating Program Info State District of Columbia Program Type Utility Rebate Program Rebate Amount $600 Provider Grays Harbor PUD Since October 2001, Grays Harbor PUD has offered a rebate program for the installation of solar water heaters. Rebates of $600 are available for the installation of solar collectors of 40 square feet or more. Only customers who currently use electricity for hot water are eligible. This rebate is available on a case-by-case basis, so you must contact the utility in order to take advantage of it. Customers may choose a [http://dsireusa.org/incentives/incentive.cfm?Incentive_Code=WA09F&re=1&ee=1

412

Covered Product Category: Gas Storage Water Heaters | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Gas Storage Water Heaters Gas Storage Water Heaters Covered Product Category: Gas Storage Water Heaters October 7, 2013 - 10:43am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including gas storage water heaters, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

413

Solar Water Heaters and the Economy | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heaters and the Economy Solar Water Heaters and the Economy Solar Water Heaters and the Economy July 11, 2012 - 11:59am Addthis Ernie Tucker Editor, National Renewable Energy Laboratory These are the days of hot sun and mortgage refinance frenzy. Somehow, they've both combined in my mind to make me ponder the economics of a solar water heater. Because the sun's been beating down on our garden hose, the initial flush of water can be very hot. The warm spray reminded me of the times on camping trips when we'd bring along a portable solar shower -- essentially a black plastic bag with a tube and shower nozzle -- for bathing. While not an endless supply (perhaps 10 gallons), it was a very enjoyable luxury. Of course, it assumes that there's plenty of sunshine, but if so -- voila -- a

414

Grays Harbor PUD - Solar Water Heater Loan | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heater Loan Solar Water Heater Loan Grays Harbor PUD - Solar Water Heater Loan < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Maximum Rebate not specified Program Info State District of Columbia Program Type Utility Loan Program Rebate Amount not specified Provider Grays Harbor PUD Since October 2001, Grays Harbor PUD has offered a low-interest loan program (currently 4.0%) for the installation of solar water heaters. Loans are available for the installation of solar collectors of 40 square feet or more. The loans are provided through local lenders, with interest subsidized by the PUD. Only customers who currently use electricity for hot water are eligible. Pre-approval is required for this loan and loan amounts are determined on a case-by-case basis.

415

New Braunfels Utilities - Residential Solar Water Heater Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

New Braunfels Utilities - Residential Solar Water Heater Rebate New Braunfels Utilities - Residential Solar Water Heater Rebate Program New Braunfels Utilities - Residential Solar Water Heater Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State Texas Program Type Utility Rebate Program Rebate Amount $0.265/kWh Provider New Braunfels Utilities New Braunfels Utilities offers a rebate for residential customers who purchase and install solar water heating systems on eligible homes. A rebate of the equivalent of $0.265 per kWh is available to these customers. The maximum rebate amount is $900 for participating customers. Applicants must have an active residential electric service account with NBU in order to be eligible. Solar water heaters must preheat water for an electric

416

Heat Recovery Consideration for Process Heaters and Boilers  

E-Print Network [OSTI]

The largest single area for industrial energy conservation is in the improvement of combustion efficiencies for heaters and boilers. A number of methods can be employed to recover heat. The most common are by use of recuperative air preheaters...

Kumar, A.

1984-01-01T23:59:59.000Z

417

Split system CO2 heat pump water heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Split-system-CO2-heat-pump-water-heaters- Sign In About | Careers | Contact | Investors | bpa.gov Search Policy & Reporting Expand Policy & Reporting EE Sectors Expand EE...

418

An Analysis of Steam Process Heater Condensate Drainage Options  

E-Print Network [OSTI]

The production and reliability performance of Steam Process Heaters can be significantly affected by the condensate drainage design that is employed. There are currently a variety of drainage options which can be confusing to a system designer who...

Risko, J. R.

419

Monitoring SERC Technologies: On-Demand Tankless Water Heaters  

Broader source: Energy.gov [DOE]

A webinar by Ethan MacCormick, VP for Services to Energy Businesses at Performance Systems Development, about On-Demand Tankless Water Heaters and how to properly monitor the installation.

420

New Home Buyer Solar Water Heater Trade-Off Study  

SciTech Connect (OSTI)

This report details the results of a research conducted in 1998 and 1999 and outlines a marketing deployment plan designed for businesses interested in marketing solar water heaters in the new home industry.

Symmetrics Marketing Corporation

1999-08-18T23:59:59.000Z

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Ninety - Two Percent Minimum Heater Efficiency By 1980  

E-Print Network [OSTI]

Technology is now available to increase heater efficiencies to 92 percent and more. By 1980, this technology will be field proven and corrosion and reliability problems identified and resolved. Recent studies have shown that a minimum efficiency...

Mieth, H. C.; Hardie, J. E.

1980-01-01T23:59:59.000Z

422

Marshall Municipal Utilities- Solar Thermal Water Heater Rebate Program  

Broader source: Energy.gov [DOE]

Marshall Municipal Utilities (MMU) offers residential customers rebates for installing a ENERGY STAR Solar Thermal Water Heater. Rebates are based on the size of the system; MMU offers $20 per...

423

Temperature limited heater utilizing non-ferromagnetic conductor  

DOE Patents [OSTI]

A heater is described. The heater includes a ferromagnetic conductor and an electrical conductor electrically coupled to the ferromagnetic conductor. The ferromagnetic conductor is positioned relative to the electrical conductor such that an electromagnetic field produced by time-varying current flow in the ferromagnetic conductor confines a majority of the flow of the electrical current to the electrical conductor at temperatures below or near a selected temperature.

Vinegar; Harold J. (Bellaire, TX), Harris; Christopher Kelvin (Houston, TX)

2012-07-17T23:59:59.000Z

424

Estimating the Cost and Energy Efficiency of a Solar Water Heater |  

Broader source: Energy.gov (indexed) [DOE]

Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater May 30, 2012 - 3:09pm Addthis Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR What does this mean for me? Solar water heaters cost more to purchase and install but may save you money in the long run. Estimate the annual operating costs and compare several solar water heaters to determine whether it is worth investing in a more efficient system. Solar water heating systems usually cost more to purchase and install than conventional water heating systems. However, a solar water heater can

425

Estimating the Cost and Energy Efficiency of a Solar Water Heater |  

Broader source: Energy.gov (indexed) [DOE]

Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater Estimating the Cost and Energy Efficiency of a Solar Water Heater May 30, 2012 - 3:09pm Addthis Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR Solar water heaters are more efficient the gas or electric heaters. | Chart credit ENERGY STAR What does this mean for me? Solar water heaters cost more to purchase and install but may save you money in the long run. Estimate the annual operating costs and compare several solar water heaters to determine whether it is worth investing in a more efficient system. Solar water heating systems usually cost more to purchase and install than conventional water heating systems. However, a solar water heater can

426

Process Systems Engineering Optimal Synthesis of Refrigeration Cycles  

E-Print Network [OSTI]

Process Systems Engineering Optimal Synthesis of Refrigeration Cycles and Selection of Refrigerants, University Park, PA 16802 The optimal synthesis of the refrigeration configuration and the selection of the best refrigerants that satisfy a set of process cooling duties at different temperatures is ad- dressed

Maranas, Costas

427

DOE Publishes Supplemental Proposed Determination for Miscellaneous Residential Refrigeration Products  

Broader source: Energy.gov [DOE]

The Department of Energy has published a supplemental proposed determination regarding miscellaneous residential refrigeration products.

428

Determining Benefits and Costs of Improved Water Heater Efficiencies  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Determining Benefits and Costs of Improved Water Heater Efficiencies Determining Benefits and Costs of Improved Water Heater Efficiencies Title Determining Benefits and Costs of Improved Water Heater Efficiencies Publication Type Report LBNL Report Number LBNL-45618 Year of Publication 2000 Authors Lekov, Alexander B., James D. Lutz, Xiaomin Liu, Camilla Dunham Whitehead, and James E. McMahon Document Number LBNL-45618 Date Published May 4 Abstract Economic impacts on individual consumers from possible revisions to U.S. residential water heater energy-efficiency standards are examined using a life-cycle cost (LCC) analysis. LCC is the consumer's cost of purchasing and installing a water heater and operating it over its lifetime. This approach makes it possible to evaluate the economic impacts on individual consumers from the revised standards. The methodology allows an examination of groups of the population which benefit or lose from suggested efficiency standards. The results show that the economic benefits to consumers are significant. At the efficiency level examined in this paper, 35% of households with electric water heaters experience LCC savings, with an average savings of $106, while 4% show LCC losses, with an average loss of $40 compared to a pre-standard LCC average of $2,565. The remainder of the population (61%) are largely unaffected.

429

Proceedings: commercial refrigeration research workshop. Summary  

SciTech Connect (OSTI)

The purpose of this workshop was to identify the state-of-the-art and determine research needs for improving energy use and demand in commercial refrigeration applications. Workshop attendees included research and development, technical operations and marketing people from manufacturers of supermarket refrigeration, space conditioning, and energy management systems equipment, and from supermarket chains and electric utilities. Presentations were given on best current practice and research needs from the perspective of each of these industry segments. Working groups identified ten important research, development and equipment demonstration projects to improve the efficiency of refrigerating equipment, heating, ventilating and air-conditioning (HVAC) equipment, and other energy-using systems in supermarkets.

Blatt, M.H.

1984-10-01T23:59:59.000Z

430

PhD student in Energy Technology, specifically in Commercial refrigeration systems with CO2 as refrigerant  

E-Print Network [OSTI]

the use of carbon dioxide as refrigerant in supermarket refrigeration systems. The work includes fieldPhD student in Energy Technology, specifically in Commercial refrigeration systems with CO2 a PhD student in Energy Technology, specifically Commercial refrigeration systems with CO2

Kazachkov, Ivan

431

Non-CFC vacuum alternatives for the energy-efficient insulation of household refrigerators: Design and use  

SciTech Connect (OSTI)

Energy efficiency, environmental issues, and market incentives all encourage government and industry to continue work on thin-profile vacuum insulations for domestic refrigerators and freezers (R/Fs). Vacuum insulations promise significant improvement in thermal savings over current insulations; the technical objective of one design is an R-value of better than 10 (hr-ft{sup 2}-F/Btu) in 0.1 in. thickness. If performance is improved by a factor of 10 over that of CFC-blown insulating foams, the new insulations (made without CFCs or other potentially troublesome fill gases) will change the design and improve the efficiency of refrigerators. Such changes will meet the conservation, regulatory, and market drivers now strong in developed countries and likely to increase in developing countries. Prototypes of various designs have been tested in the laboratory and in factories, and results to date confirm the good thermal performance of these thin-profile alternatives. The next step is to resolve issues of reliability and cost effectiveness. 34 refs., 4 figs.

Potter, T.F.; Benson, D.K.

1991-01-01T23:59:59.000Z

432

Status of not-in-kind refrigeration technologies for household space conditioning, water heating and food refrigeration  

SciTech Connect (OSTI)

This paper presents a review of the next generation not-in-kind technologies to replace conventional vapor compression refrigeration technology for household applications. Such technologies are sought to provide energy savings or other environmental benefits for space conditioning, water heating and refrigeration for domestic use. These alternative technologies include: thermoacoustic refrigeration, thermoelectric refrigeration, thermotunneling, magnetic refrigeration, Stirling cycle refrigeration, pulse tube refrigeration, Malone cycle refrigeration, absorption refrigeration, adsorption refrigeration, and compressor driven metal hydride heat pumps. Furthermore, heat pump water heating and integrated heat pump systems are also discussed due to their significant energy saving potential for water heating and space conditioning in households. The paper provides a snapshot of the future R&D needs for each of the technologies along with the associated barriers. Both thermoelectric and magnetic technologies look relatively attractive due to recent developments in the materials and prototypes being manufactured.

Bansal, Pradeep [ORNL; Vineyard, Edward Allan [ORNL; Abdelaziz, Omar [ORNL

2012-01-01T23:59:59.000Z

433

Elastic Metal Alloy Refrigerants: Thermoelastic Cooling  

SciTech Connect (OSTI)

BEETIT Project: UMD is developing an energy-efficient cooling system that eliminates the need for synthetic refrigerants that harm the environment. More than 90% of the cooling and refrigeration systems in the U.S. today use vapor compression systems which rely on liquid to vapor phase transformation of synthetic refrigerants to absorb or release heat. Thermoelastic cooling systems, however, use a solid-state material—an elastic shape memory metal alloy—as a refrigerant and a solid to solid phase transformation to absorb or release heat. UMD is developing and testing shape memory alloys and a cooling device that alternately absorbs or creates heat in much the same way as a vapor compression system, but with significantly less energy and a smaller operational footprint.

None

2010-10-01T23:59:59.000Z

434

Intra-molecular refrigeration in enzymes  

E-Print Network [OSTI]

We present a simple mechanism for intra-molecular refrigeration, where parts of a molecule are actively cooled below the environmental temperature. We discuss the potential role and applications of such a mechanism in biology, in particular in enzymatic reactions.

Hans J. Briegel; Sandu Popescu

2009-12-14T23:59:59.000Z

435

Refrigeration system having standing wave compressor  

DOE Patents [OSTI]

A compression-evaporation refrigeration system, wherein gaseous compression of the refrigerant is provided by a standing wave compressor. The standing wave compressor is modified so as to provide a separate subcooling system for the refrigerant, so that efficiency losses due to flashing are reduced. Subcooling occurs when heat exchange is provided between the refrigerant and a heat pumping surface, which is exposed to the standing acoustic wave within the standing wave compressor. A variable capacity and variable discharge pressure for the standing wave compressor is provided. A control circuit simultaneously varies the capacity and discharge pressure in response to changing operating conditions, thereby maintaining the minimum discharge pressure needed for condensation to occur at any time. Thus, the power consumption of the standing wave compressor is reduced and system efficiency is improved.

Lucas, Timothy S. (Glen Allen, VA)

1992-01-01T23:59:59.000Z

436

Air Conditioning Heating and Refrigeration Institute Comment  

Broader source: Energy.gov [DOE]

These comments are submitted by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) in response to the U.S. Department of Energy’s (DOE) notice in the July 3, 2014 Federal Register...

437

Improving Industrial Refrigeration System Efficiency - Actual Applications  

E-Print Network [OSTI]

cycle cooling during winter operation, compressor intercooling, direct refrigeration vs. brine cooling, insulation of cold piping to reduce heat gain, multiple screw compressors for improved part load operation, evaporative condensers for reduced system...

White, T. L.

1980-01-01T23:59:59.000Z

438

Residential Refrigerator Recycling Ninth Year Retention Study  

E-Print Network [OSTI]

Residential Refrigerator Recycling Ninth Year Retention Study Study ID Nos. 546B, 563 Prepared RECYCLING PROGRAMS Study ID Nos. 546B and 563 Prepared for Southern California Edison Rosemead, California

439

Working Fluids Low Global Warming Potential Refrigerants  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Working Fluids Low GWP Working Fluids Low GWP Refrigerants - CRADA Ed Vineyard Oak Ridge National Laboratory vineyardea@ornl.gov (865) 574-0576 3 April 2013 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: - High GWP refrigerants increase CO 2 equivalent emissions for HVAC&R equipment - Low GWP alternatives may increase energy consumption, introduce safety risks, require significant modifications to equipment, and have higher costs

440

Working Fluids Low Global Warming Potential Refrigerants  

Broader source: Energy.gov (indexed) [DOE]

Working Fluids Low GWP Working Fluids Low GWP Refrigerants - CRADA Ed Vineyard Oak Ridge National Laboratory vineyardea@ornl.gov (865) 574-0576 3 April 2013 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: - High GWP refrigerants increase CO 2 equivalent emissions for HVAC&R equipment - Low GWP alternatives may increase energy consumption, introduce safety risks, require significant modifications to equipment, and have higher costs

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Combined cold compressor/ejector helium refrigerator  

DOE Patents [OSTI]

A refrigeration apparatus having an ejector operatively connected with a cold compressor to form a two-stage pumping system. This pumping system is used to lower the pressure, and thereby the temperature of a bath of boiling refrigerant (helium). The apparatus as thus arranged and operated has substantially improved operating efficiency when compared to other processes or arrangements for achieving a similar low pressure.

Brown, Donald P. (Southold, NY)

1985-01-01T23:59:59.000Z

442

Uninterrupted power supply for autonomous small refrigerators  

Science Journals Connector (OSTI)

The objective of this paper is to describe salient features of a small refrigerator powered by a field of photovoltaic panels backed up by a petrol-start, kerosene-run portable generator set. Such units find applications in medical shops, veterinary applications and storage of vaccines in primary health centers. The modular arrangement allows use of certain components as a part of an uninterrupted power supply system for such refrigerators. Some preliminary results on temperature distributions and performance data are also presented.

Thomachan A. Kattakayam; K. Srinivasan

1998-01-01T23:59:59.000Z

443

ARI delegation to Japan on Alternative Refrigerants  

SciTech Connect (OSTI)

Researchers from ARI member companies spoke at the International Conference on Alternative Refrigerants in Tokyo and visited several Japanese organizations for the purpose of exchanging information on alternative refrigerants. The specific purpose of the meetings was to review the methods being utilized to screen alternatives to CFCs and HCFCs: materials compatibility screening methods, lubricant testing techniques, as well as flammability studies. A list of papers presented at the conference is included.

Not Available

1993-02-01T23:59:59.000Z

444

Combined cold compressor/ejector helium refrigerator  

DOE Patents [OSTI]

A refrigeration apparatus having an ejector operatively connected with a cold compressor to form a two-stage pumping system. This pumping system is used to lower the pressure, and thereby the temperature of a bath of boiling refrigerant (helium). The apparatus as thus arranged and operated has substantially improved operating efficiency when compared to other processes or arrangements for achieving a similar low pressure.

Brown, D.P.

1984-06-05T23:59:59.000Z

445

Springfield Utility Board - Residential Energy Efficiency Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

Springfield Utility Board - Residential Energy Efficiency Rebate Springfield Utility Board - Residential Energy Efficiency Rebate Program Springfield Utility Board - Residential Energy Efficiency Rebate Program < Back Eligibility Low-Income Residential Multi-Family Residential Residential Savings Category Home Weatherization Commercial Weatherization Appliances & Electronics Sealing Your Home Ventilation Heating & Cooling Commercial Heating & Cooling Heat Pumps Water Heating Program Info State Oregon Program Type Utility Rebate Program Rebate Amount Refrigerators/Freezers: $25 Electric Water Heaters: $25 Clothes Washers: $30 - $80 Recycle Refrigerator/Freezer: $25 Duct Sealing/Testing: $150 - $400 Heat Pump: $500 Ductless Heat Pump: $1,000 Insulation: 50% (100% for qualified low income customers) Provider Springfield Utility Board

446

Empire Electric Association - Residential Energy Efficiency Credit Program  

Broader source: Energy.gov (indexed) [DOE]

Residential Residential State Government Savings Category Appliances & Electronics Heating & Cooling Commercial Heating & Cooling Heat Pumps Water Heating Program Info State Colorado Program Type Utility Rebate Program Rebate Amount HVAC Equipment: $250 - $300; additional rebates available for higher efficiency levels Controlled Resistance Heating: $24 - $32/kW Terminal Unit Heat Pump: $170 Water Heater: $100; additional rebates available for warranties, timers, and controls Split System A/C: $300/unit Refrigerator/freezer: $90/unit Refrigerator/freezer Recycling: $40 Dishwasher: $60 Clothes Washer: $80 Provider Empire Electric Association, Inc. Empire Electric Association provides financial incentives to its residential consumers who upgrade to energy efficient appliances and HVAC

447

Ameren Missouri (Electric) - Residential Energy Efficiency Rebate Programs  

Broader source: Energy.gov (indexed) [DOE]

Ameren Missouri (Electric) - Residential Energy Efficiency Rebate Ameren Missouri (Electric) - Residential Energy Efficiency Rebate Programs Ameren Missouri (Electric) - Residential Energy Efficiency Rebate Programs < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Commercial Lighting Lighting Water Heating Maximum Rebate Refrigerator/Freezer Recycling: 3 units Program Info State Missouri Program Type Utility Rebate Program Rebate Amount CFL's: In-store discounts, Online Store Refrigerator/Freezer Recycling: $50 Air Source Heat Pump: $300 - $650 Central AC: $150 - $425 Electronically Commutated Blower Motor: $50 - $100 Geothermal Heat Pump: $600 Diagnostic Tune-Up: $75 Programmable Thermostat: $25 Electric Storage Water Heater: $25

448

Heat Pump Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Water Heater Basics Water Heater Basics Heat Pump Water Heater Basics August 19, 2013 - 2:59pm Addthis Illustration of a heat pump water heater, which looks like a tall cylinder with a small chamber on top and a larger one on the bottom. In the top chamber are a fan, a cylindrical compressor, and an evaporator that runs along the inside of the chamber. Jutting out from the exterior of the bottom chamber is a temperature and pressure relief valve. This valve has a tube called a hot water outlet attached to the top. Below the valve is the upper thermostat, a small square outside the cylinder that is attached to a curved tube inside the heater. Resistance elements run from the upper thermostat to the similarly shaped lower thermostat. Below the lower thermostat is a drain valve with a cold water inlet attached to the top. Inside the cylinder is an anode, a series of thin tubes running through the bottom chamber to a coiled tube called a condenser. Insulation runs along the inside of the cylinder.

449

Performance characteristics of solar air heater with surface mounted obstacles  

Science Journals Connector (OSTI)

Abstract The performance of conventional solar air heaters (SAHs) can be improved by providing obstacles on the heated wall (i.e. on the absorber plate). Experiments have been performed to collect heat transfer and flow-friction data from an air heater duct with delta-shaped obstacles mounted on the absorber surface and having an aspect ratio 6:1 resembling the conditions close to the solar air heaters. This study encompassed for the range of Reynolds number (Re) from 2100 to 30,000, relative obstacle height (e/H) from 0.25 to 0.75, relative obstacle longitudinal pitch (Pl/e) from 3/2 to 11/2, relative obstacle transverse pitch (Pt/b) from 1 to 7/3 and the angle of incidence (?) varied from 30° to 90°. The thermo-hydraulic performance characteristics of SAH have been compared with the previous published works and the optimum range of the geometries have been explored for the better performance of such air-heaters compared to the other designs of solar air heaters.

Adisu Bekele; Manish Mishra; Sushanta Dutta

2014-01-01T23:59:59.000Z

450

Low-GWP Refrigerants Research Project | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Emerging Technologies » Low-GWP Refrigerants Research Project Emerging Technologies » Low-GWP Refrigerants Research Project Low-GWP Refrigerants Research Project The U.S. Department of Energy is currently conducting research into low global warming potential (GWP) refrigerants. As concerns about climate change intensify, it is becoming increasingly clear that suitable low-GWP refrigerants will be needed for both new and existing residential and commercial heating, ventilation, air conditioning, and refrigeration (HVAC&R) equipment. Project Description This project seeks to develop alternative refrigerants for HVAC&R equipment. The overall environmental impacts of alternative refrigerants will be assessed using a life cycle climate performance model that accounts for direct emissions associated with refrigerant leaks and indirect

451

SMUD - Solar Water Heater Rebate Program | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Water Heater Rebate Program Solar Water Heater Rebate Program SMUD - Solar Water Heater Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Solar Water Heating Program Info State California Program Type Utility Rebate Program Rebate Amount 500 - 1,500 per system, depending on energy savings Provider Sacramento Municipal Utility District The Sacramento Municipal Utility District's (SMUD) Solar Domestic Hot Water Program provides rebates and/or loan financing to customers who install solar water heating systems. The amount of the rebate depends on how much electricity the system will offset annually: * 800 - 1,399 kWh: $500 * 1,400 - 2,199 kWh: $1,000 * 2,200 kWh or greater: $1,500 . All solar water-heating units must meet standards set by the Solar Rating

452

FEMP Designated Product Assessment for Commercial Gas Water Heaters  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

FEMP Designated Product Assessment for Commercial Gas Water Heaters FEMP Designated Product Assessment for Commercial Gas Water Heaters Title FEMP Designated Product Assessment for Commercial Gas Water Heaters Publication Type Report LBNL Report Number LBNL-5514E Year of Publication 2010 Authors Lutz, James D. Subsidiary Authors Energy Analysis Department Document Number LBNL-5514E Pagination 8 Date Published April 1 Publisher Lawrence Berkeley National Laboratory City Berkeley ISBN Number LBNL-5514E Abstract None Notes This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology, State, and Community Programs, of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231. Attachment Size PDF 240.22 KB Google Scholar BibTex RIS RTF XML Alternate URL: http://eetd.lbl.gov/node/50317

453

Savings Project: Insulate Your Water Heater Tank | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Savings Project: Insulate Your Water Heater Tank Savings Project: Insulate Your Water Heater Tank Savings Project: Insulate Your Water Heater Tank Addthis Project Level medium Energy Savings $20-$45 annually Time to Complete 1.5 hours Overall Cost $30 Insulate your hot water tank to save energy and money. | Photo courtesy of iStockphoto.com/glennebo Insulate your hot water tank to save energy and money. | Photo courtesy of iStockphoto.com/glennebo Just like insulating your walls or roof, insulating your hot water tank is an easy and inexpensive way to improve energy efficiency and save you money each month. If your water tank is new, it is likely already insulated. If you have an older hot water tank, check to see if it has insulation with an R-value of at least 24. If not, consider insulating your water tank, which

454

Experimental study of integrated collector storage solar water heaters  

Science Journals Connector (OSTI)

Three Integrated Collector Storage Solar Water Heaters (ICSSWH) have been designed, constructed and experimentally studied in comparison to a Flat Plate Thermosiphonic Unit (FPTU). Each of the ICS experimental models consists of one cylindrical tank horizontally mounted in a stationary symmetrical Compound Parabolic Concentrating (CPC) reflector trough. The main objective is the design and construction of low cost solar water heaters with improved thermal performance and lower possible depths. The experimental models can be mounted on horizontal as well as on inclined roofs by adopting the lowest possible depth. The results show that these solar devices perform more than effectively all year long. This could contribute significantly on the development of ICS type solar water heaters.

M. Souliotis; D. Chemisana; Y.G. Caouris; Y. Tripanagnostopoulos

2013-01-01T23:59:59.000Z

455

Outdoor Outfitter Gets Greener With Solar Water Heater | Department of  

Broader source: Energy.gov (indexed) [DOE]

Outdoor Outfitter Gets Greener With Solar Water Heater Outdoor Outfitter Gets Greener With Solar Water Heater Outdoor Outfitter Gets Greener With Solar Water Heater October 8, 2010 - 12:51pm Addthis L.L. Bean’s flagship store sees nearly 3 million visitors each year. The store now uses solar-heated water for showers, restrooms and two cafes. | Photo courtesy of L.L. Bean | L.L. Bean's flagship store sees nearly 3 million visitors each year. The store now uses solar-heated water for showers, restrooms and two cafes. | Photo courtesy of L.L. Bean | Lindsay Gsell L.L. Bean is known for its outdoor apparel- jackets, backpacks and cozy winter sweaters. However, the company does more than just dress for the outdoors, it also works to protect and preserve it. For nearly 100 years, L.L. Bean has been committed to environmental conservation and

456

Feedback regulated induction heater for a flowing fluid  

DOE Patents [OSTI]

A regulated induction heater for heating a stream of flowing fluid to a predetermined desired temperature. The heater includes a radiofrequency induction coil which surrounds a glass tube through which the fluid flows. A heating element consisting of a bundle of approximately 200 stainless steel capillary tubes located within the glass tube couples the output of the induction coil to the fluid. The temperature of the fluid downstream from the heating element is sensed with a platinum resistance thermometer, the output of which is applied to an adjustable porportional and integral feedback control circuit which regulates the power applied to the induction coil. The heater regulates the fluid temperature to within 0.005/sup 0/C at a flow rate of 50 cm/sup 3//sec with a response time of less than 0.1 second, and can accommodate changes in heat load up to 1500 watts.

Migliori, A.; Swift, G.W.

1984-06-13T23:59:59.000Z

457

Feedback regulated induction heater for a flowing fluid  

DOE Patents [OSTI]

A regulated induction heater for heating a stream of flowing fluid to a predetermined desired temperature. The heater includes a radiofrequency induction coil which surrounds a glass tube through which the fluid flows. A heating element consisting of a bundle of approximately 200 stainless steel capillary tubes located within the glass tube couples the output of the induction coil to the fluid. The temperature of the fluid downstream from the heating element is sensed with a platinum resistance thermometer, the output of which is applied to an adjustable proportional and integral feedback control circuit which regulates the power applied to the induction coil. The heater regulates the fluid temperature to within 0.005.degree. C. at a flow rate of 50 cm.sup.3 /second with a response time of less than 0.1 second, and can accommodate changes in heat load up to 1500 watts.

Migliori, Albert (Santa Fe, NM); Swift, Gregory W. (Los Alamos, NM)

1985-01-01T23:59:59.000Z

458

Our Environment in Hot Water: Comparing Water Heaters, A Life Cycle Approach Comparing Tank and Tankless Water Heaters in California  

SciTech Connect (OSTI)

Residential water heating is a large source of energy use in California homes. This project took a life cycle approach to comparing tank and tankless water heaters in Northern and Southern California. Information about the life cycle phases was calculated using the European Union?s Methodology study for EcoDesign of Energy-using Products (MEEUP) and the National Renewable Energy Laboratory?s Life Cycle Inventory (NREL LCI) database. In a unit-to-unit comparison, it was found that tankless water heaters would lessen impacts of water heating by reducing annual energy use by 2800 MJ/year (16% compared to tank), and reducing global warming emissions by 175 kg CO2 eqv./year (18% reduction). Overall, the production and combustion of natural gas in the use phase had the largest impact. Total waste, VOCs, PAHs, particulate matter, and heavy-metals-to-air categories were also affected relatively strongly by manufacturing processes. It was estimated that tankless water heater users would have to use 10 more gallons of hot water a day (an increased usage of approximately 20%) to have the same impact as tank water heaters. The project results suggest that if a higher percentage of Californians used tankless water heaters, environmental impacts caused by water heating would be smaller.

Lu, Alison; McMahon, James; Masanet, Eric; Lutz, Jim

2008-08-13T23:59:59.000Z

459

High Efficiency Low Emission Supermarket Refrigeration Research Project |  

Broader source: Energy.gov (indexed) [DOE]

High Efficiency Low Emission Supermarket High Efficiency Low Emission Supermarket Refrigeration Research Project High Efficiency Low Emission Supermarket Refrigeration Research Project The U.S. Department of Energy (DOE) is currently conducting research into high efficiency, low emission supermarket refrigeration technologies. Project Description The project involves the development of a supermarket refrigeration system that can reduce greenhouse gas emissions and energy consumption when compared to existing systems. The challenge is to design a system that is capable of achieving low refrigerant leak rates while significantly reducing both the energy consumption and the refrigerant charge size. Project Partners Research is being undertaken between DOE and Oak Ridge National Laboratory. Project Goals

460

Energy Efficiency Evaluation of Refrigeration Technologies in Combined Cooling, Heating and Power Systems  

E-Print Network [OSTI]

With development of absorption refrigeration technology, the cooling requirement can be met using various optional refrigeration technologies in a CCHP system, including compression refrigeration, steam double-effect absorption refrigeration, steam...

Zuo, Z.; Hu, W.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

RADIATION SAFETY MANUAL (REVISED MARCH 2010) 103 USER RADIATION SURVEY REPORT  

E-Print Network [OSTI]

on hand, is the isotope secured? e. Refrigerator and other storage area logs current? f. Refrigerators/freezers

462

COMBINING DIVERSE DATA SOURCES FOR CEDSS, AN AGENT-BASED MODEL OF DOMESTIC ENERGY DEMAND  

E-Print Network [OSTI]

the heating system, a cooker, refrigerator and washinghere are heating systems, cookers, cold appliances (heating systems, cookers, refrigerators, freezers, washing

Gotts, Nicholas Mark; Polhill, Gary; Craig, Tony; Galan-Diaz, Carlos

2014-01-01T23:59:59.000Z

463

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review ...  

Energy Savers [EERE]

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review Presenter: Tony Bouza, U.S. Department of Energy This...

464

Electric Blanket vs. Space Heater: #EnergyFaceoff Round 3 Heats...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Blanket vs. Space Heater: EnergyFaceoff Round 3 Heats Up Electric Blanket vs. Space Heater: EnergyFaceoff Round 3 Heats Up November 17, 2014 - 9:49am Q&A Which appliance do you...

465

Electric Blanket Delivers K.O. to Space Heater During #EnergyFaceoff...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Electric Blanket Delivers K.O. to Space Heater During EnergyFaceoff Round Three Electric Blanket Delivers K.O. to Space Heater During EnergyFaceoff Round Three November 19, 2014...

466

Numerical analysis of thermal-hydrological conditions in the single heater test at Yucca Mountain  

E-Print Network [OSTI]

Single Heater Test at Yucca Mountain, LBNL-39789, E.O. Law­Single Heater Test at Yucca Mountain Jens T. Birkholzer andwaste repository at Yucca Mountain. The heating phase of the

Birkholzer, Jens T.; Tsang, Yvonne W.

1998-01-01T23:59:59.000Z

467

La Plata Electric Association - Energy Efficient Equipment Rebate Program |  

Broader source: Energy.gov (indexed) [DOE]

La Plata Electric Association - Energy Efficient Equipment Rebate La Plata Electric Association - Energy Efficient Equipment Rebate Program La Plata Electric Association - Energy Efficient Equipment Rebate Program < Back Eligibility Commercial Industrial Residential Savings Category Appliances & Electronics Heating & Cooling Commercial Heating & Cooling Heat Pumps Commercial Lighting Lighting Manufacturing Water Heating Program Info State Colorado Program Type Utility Rebate Program Rebate Amount Dishwasher: $40 Clothes Washer: $40 Refrigerator/Freezer: $40 Refrigerator/Freezer Recycling: $25 Water Heaters: $75 - $300 ETS Heaters: $20 - $30/kWh Heater Timing Devices: $25 Motors: $9/HP Motor Wiring Assistance: $1.50/HP Air-source Heat Pumps: Contact LPEA Geothermal Heat Pumps: Contact LPEA Energy Efficient Lighting (Commercial Only): $250/kW reduced

468

Sangre De Cristo Electric Association - Energy Efficiency Credit Program |  

Broader source: Energy.gov (indexed) [DOE]

Sangre De Cristo Electric Association - Energy Efficiency Credit Sangre De Cristo Electric Association - Energy Efficiency Credit Program Sangre De Cristo Electric Association - Energy Efficiency Credit Program < Back Eligibility Commercial Residential Savings Category Appliances & Electronics Heating & Cooling Commercial Heating & Cooling Heat Pumps Water Heating Program Info State Colorado Program Type Utility Rebate Program Rebate Amount Resistive Heat Space Heater: $10/kW ETS Space Heater: $25/kW Heat Pump: Contact the Electric Association Water Heater: $100/unit, plus $25 for lifetime warranty Device Timers: $25 Refrigerator: $40 Freezer: $40 Refrigerator/Freezer Recycling Clothes Washer:$40 Dishwasher: $40 Provider Sangre De Cristo Electric Association The Sangre De Cristo Electric Association (SDCEA) offers the Energy

469

Refrigerator Standards Save Consumers $ Billions | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Refrigerator Standards Save Consumers $ Billions Refrigerator Standards Save Consumers $ Billions Refrigerator Standards Save Consumers $ Billions March 5, 2013 - 10:35am Addthis Refrigerator Standards Refrigerator Standards Refrigerator technology has come a long way since Dr. John Gorrie (1803 - 1855), a forward-looking inventor, was granted U. S. Patent #8080 for mechanical refrigeration in 1851. In those days, ice was expensive, if it was even available: Blocks of natural ice were carved from frozen lakes and rivers and stored in special warehouses under layers of sawdust for insulation. By the 1890s, pollution and sewage dumping caused by population growth compromised sources of pure, natural ice, threatening the brewing, meat-packing, and dairy industries. As these and other industries sought better solutions, modern refrigeration technology started to evolve.

470

Optimal Design Refrigeration System for a Mucilage Glue Fiber Factory  

E-Print Network [OSTI]

In a mucilage glue fiber factory, the design of the refrigeration system takes into account the characteristics of mucilage glue fiber production and fully uses the refrigeration compressor heat to economize energy and reduce the production cost...

Tan, C.; Liu, J.; Tang, F.; Liu, Y.

2006-01-01T23:59:59.000Z

471

VEE-0079- In the Matter of Diversified Refrigeration, Inc.  

Broader source: Energy.gov [DOE]

Diversified Refrigeration, Inc. (DRI) requests a six-month exception from the 2001 energy appliance efficiency standards for built-in refrigerators that become effective July 1, 2001. As explained...

472

Fully portable, highly flexible dilution refrigerator systems for neutron scattering  

E-Print Network [OSTI]

775 Fully portable, highly flexible dilution refrigerator systems for neutron scattering P. A systems developed specifically for neutron scattering environ- ments. The refrigerators are completely relatively recently however, the lowest temperatures available in almost all neutron scattering laboratories

Boyer, Edmond

473

Energy Savings from Floating Head Pressure in Ammonia Refrigeration Systems  

E-Print Network [OSTI]

This paper presents case studies of two moderately sized ammonia refrigeration systems retrofitted for floating head pressure control. It also presents a parametric analysis to assist in selecting appropriate pressures in an ammonia refrigeration...

Barrer, P. J.; Jones, S. M.

474

International Refrigeration: Proposed Penalty (2012-CE-1510)  

Broader source: Energy.gov (indexed) [DOE]

International Refrigeration Products International Refrigeration Products (room air conditioners) ) ) ) ) ) Case Number: 2012-CE-1510 NOTICE OF PROPOSED CIVIL PENALTY Date issued: July 9, 2012 Number of alleged violations: 5475 (365 days, 15 models) Maximum possible assessment: $1,095,000 Proposed civil penalty: $109,500 The U.S. Department of Energy ("DOE") Office of the General Counsel, Office of Enforcement, alleges that International Refrigeration Products ("IRP") has violated cettain provisions of the Energy Policy and Conservation Act, 42 U.S.C. § 6291 et seq. ("the Act"), and 10 C.P.R. § 429.12. Specifically, DOE alleges: 1. IRP has manufactured 1 a variety of Sea Breeze brand room air conditioners, including basic models WA46YR, WA48YRX, WA410YRX, WA412YRX, WH418ZRX,

475

Of Refrigerators & Regulations | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Of Refrigerators & Regulations Of Refrigerators & Regulations Of Refrigerators & Regulations February 8, 2011 - 9:29am Addthis Jesse Lee White House Director of Online Affairs Editor's Note: This entry has been cross-posted from The White House Blog. For those interested in the President's remarks to the U.S. Chamber of Commerce and his views on the shared responsibilities of government and business to the American people, our post earlier will give a suitable overview. For those interested in the details of the President's Executive Order on reviewing regulations and their impacts on the economy, Cass Sunstein's post this morning will also be of value. But the President also took a moment during his speech to put the debate over regulation in a different perspective, and to break through the false dichotomy so often

476

Optimal performance of endoreversible quantum refrigerators  

E-Print Network [OSTI]

The derivation of general performance benchmarks is important in the design of highly optimized heat engines and refrigerators. To obtain them, one may model phenomenologically the leading sources of irreversibility ending up with results which are model-independent, but limited in scope. Alternatively, one can take a simple physical system realizing a thermodynamic cycle and assess its optimal operation from a complete microscopic description. We follow this approach in order to derive the coefficient of performance at maximum cooling rate for \\textit{any} endoreversible quantum refrigerator. At striking variance with the \\textit{universality} of the optimal efficiency of heat engines, we find that the cooling performance at maximum power is crucially determined by the details of the specific system-bath interaction mechanism. A closed analytical benchmark is found for endoreversible refrigerators weakly coupled to unstructured bosonic heat baths: an ubiquitous case study in quantum thermodynamics.

Luis A. Correa; José P. Palao; Gerardo Adesso; Daniel Alonso

2014-11-24T23:59:59.000Z

477

Modeling and Test-and-Rate Methods for Innovative Thermosiphon Solar Water Heaters: Preprint  

SciTech Connect (OSTI)

Conference paper regarding research in modeling and test-and-rate methods for thermosiphon solar domestic water heaters.

Burch, J.; Shoukas, G.; Brandemuhl, M.; Krarti, M.

2006-05-01T23:59:59.000Z

478

Field Testing of Pre-Production Prototype Residential Heat Pump Water Heaters  

Broader source: Energy.gov [DOE]

Provides and overview of field testing of 18 pre-production prototype residential heat pump water heaters

479

Order Code RL34294 Energy Independence and Security Act of 2007  

E-Print Network [OSTI]

includes residential refrigerators, freezers, refrigerator-freezers, metal halide lamps, and commercial walk-in coolers and freezers. ! Repeal of Oil and Gas Tax Incentives. The enacted law includes repeal

Laughlin, Robert B.

480

Conventional Storage Water Heater Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Conventional Storage Water Heater Basics Conventional Storage Water Heater Basics Conventional Storage Water Heater Basics July 30, 2013 - 3:39pm Addthis Illustration showing the components of a storage water heater. On top of the tank are two thin pipes; one pipe is the hot water outlet, and the other is the cold water inlet. A large pipe in the middle is called a vent pipe. A pressure/temperature relief valve is also on top of the tank and is connected to an open pipe that runs down the side of the tank. Another valve near the bottom of the outside of the tank is the thermostat and gas valve. A cutout shows the parts inside the tank, which include a large tube called a flue tube/heat exchanger. Inside this tube is a jagged insert called a flue baffle. Beside the flue tube/heat exchanger is a thin tube called the anode rod. At the bottom of the tank is a gas burner, and beneath the burner are combustion air openings.

Note: This page contains sample records for the topic "heaters refrigerators freezers" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Silicon microbench heater elements for packaging opto-electronic devices  

SciTech Connect (OSTI)

Examples are presented of the application of Lawrence Livermore National Laboratory`s expertise in photonics packaging. Several examples of packaged devices will be described. Particular attention is given to silicon microbenches incorporating heaters and their use in semiconductor optical amplifier fiber pigtailing and packaging.

Combs, R.; Keiser, P.; Kleint, K.; Pocha, M.; Patterson, F.; Strand, O.T.

1995-09-01T23:59:59.000Z

482

Covered Product Category: Residential Heat Pump Water Heaters  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including residential heat pump water heaters, which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

483

Covered Product Category: Residential Electric Resistance Water Heaters  

Broader source: Energy.gov [DOE]

FEMP sets Federal efficiency requirements and provides acquisition guidance across a variety of product categories, including residential electric resistance water heaters. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

484

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters  

SciTech Connect (OSTI)

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of US climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt(tm) whole-house building simulations.

Sparn, B.; Hudon, K.; Christensen, D.

2014-06-01T23:59:59.000Z

485

Applications Tests of Commercial Heat Pump Water Heaters  

E-Print Network [OSTI]

Field application tests have been conducted on three 4 to 6-ton commercial heat pump water heater systems in a restaurant, a coin-operated laundry, and an office building cafeteria in Atlanta. The units provide space cooling while rejecting heat...

Oshinski, J. N..; Abrams, D. W.

1987-01-01T23:59:59.000Z

486

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters  

SciTech Connect (OSTI)

This report discusses how a significant opportunity for energy savings is domestic hot water heating, where an emerging technology has recently arrived in the U.S. market: the residential integrated heat pump water heater. A laboratory evaluation is presented of the five integrated HPWHs available in the U.S. today.

Sparn, B.; Hudon, K.; Christensen, D.

2011-09-01T23:59:59.000Z

487

Covered Product Category: Residential Gas Storage Water Heaters  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance across a variety of product categories, including gas storage water heaters, which are an ENERGY STAR®-qualified product category. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

488

Novel Column Heater for Fast Capillary Gas Chromatography  

Science Journals Connector (OSTI)

......expected advantage of radial heating with the coaxial heater...with other "coated" heating elements, differences...Louisiana light crude oil; 3 m 0.1 mm phenyl...expansion coefficient, and price imposed substantial practical...existing standard column heating technology. Thus, chromatographic......

E.U. Ehrmann; H.P. Dharmasena; K. Carney; E.B. Overton

1996-12-01T23:59:59.000Z

489

Restoration of Refinery Heaters Using the Technique of Prefabricated Ceramic Fiber Lined Panels  

E-Print Network [OSTI]

Refinery heater fuel requirements often represent 50% of a units operating cost. A one percent change in the efficiency of a heater firing 100 MBtu/hr amounts to more than $25,000 per year. Heater efficiency is influenced by casing hot spots, air...

Sento, H. D.

1981-01-01T23:59:59.000Z

490

Development of a Market Optimized Condensing Gas Water Heater  

SciTech Connect (OSTI)

This program covered the development of a market optimized condensing gas water heater for residential applications. The intent of the program was to develop a condensing design that minimized the large initial cost premium associated with traditional condensing water heater designs. Equally important was that the considered approach utilizes design and construction methods that deliver the desired efficiency without compromising product reliability. Standard condensing water heater approaches in the marketplace utilize high cost materials such as stainless steel tanks and heat exchangers as well as expensive burner systems to achieve the higher efficiencies. The key in this program was to develop a water heater design that uses low-cost, available components and technologies to achieve higher efficiency at a modest cost premium. By doing this, the design can reduce the payback to a more reasonable length, increasing the appeal of the product to the marketplace. Condensing water heaters have been in existence for years, but have not been able to significantly penetrate the market. The issue has typically been cost. The high purchase price associated with existing condensing water heaters, sometimes as much as $2000, has been a very difficult hurdle to overcome in the marketplace. The design developed under this program has the potential to reduce the purchase price of this condensing design by as much as $1000 as compared to traditional condensing units. The condensing water heater design developed over the course of this program led to an approach that delivered the following performance attributes: 90%+ thermal efficiency; 76,000 Btu/hr input rate in a 50 gallon tank; First hour rating greater than 180 gph; Rapid recovery time; and Overall operating condition well matched to combination heat and hot water applications. Over the final three years of the program, TIAX worked very closely with A.O. Smith Water Products Company as our commercial partner to optimize the design for manufacturing. This work included the initiation of a large field testing program (over 125 units) and an in-depth reliability program intended to minimize the risks associated with a new product introduction. At the time of this report, A.O. Smith plans to introduce this product to the marketplace in the early 2006 time period.

Peter Pescatore

2006-01-11T23:59:59.000Z

491

Retrofitting Doors on Open Refrigerated Cases  

Broader source: Energy.gov (indexed) [DOE]

Retrofitting Doors on Open Retrofitting Doors on Open Refrigerated Cases William Goetzler Navigant Consulting, Inc. wgoetzler@navigant.com (781) 270-8351 April 4, 2013 BBA Refrigeration Project Team Images courtesy of REMIS AMERICA, LLC. 2 | Building Technologies Office eere.energy.gov Technology Overview Image from Investigation of Energy- Efficient Supermarket Display Cases. 2004, Oak Ridge National Laboratory. Background and Motivation * Adding doors to open cases (retrofits) greatly reduces cold air loss - 50-80% load reduction - Load reduction = system energy savings

492

Development of a prototype optical refrigerator  

SciTech Connect (OSTI)

This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors have carried out a range of tasks directed toward the construction and testing of a proof-of-principle optical refrigerator prototype. They procured and tested new cooling elements that are at the heart of an optical refrigerator. The cooling element absorbs pump radiation and then fluoresces with nearly unity quantum efficiency. They constructed and tested a cooling chamber with low thermal emissivity walls that reduces the parasitic heating.

Epstein, R.I.; Edwards, B.C.; Sigel, G.H.

1998-01-01T23:59:59.000Z

493

Phase boundary detection for dilution refrigerators  

SciTech Connect (OSTI)

We describe a device to conveniently measure the positions of the phase boundaries in a dilution refrigerator. We show how a simple modification of a standard capacitive level gauge (segmentation of one of the electrodes) permits a direct calibration of the capacitance versus phase boundary position. We compare this direct calibration with the indirect procedure that must be adopted for a conventional capacitive level gauge. The device facilitates the correct adjustment of the {sup 3}He/{sup 4}He fraction in the dilution refrigerator.

Haar, E. ter; Martin, R.V. [DFMT, Instituto de Fisica, Universidade de Sao Paulo, C.P. 66.318, 05315-970 Sao Paulo, SP (Brazil)

2004-09-01T23:59:59.000Z

494

Helium refrigeration considerations for cryomodule design  

SciTech Connect (OSTI)

Many of the present day accelerators are based on superconducting radio frequency (SRF) cavities, packaged in cryo-modules (CM), which depend on helium refrigeration at sub-atmospheric pressures, nominally 2 K. These specialized helium refrigeration systems are quite cost intensive to produce and operate. Particularly as there is typically no work extraction below the 4.5-K supply, it is important that the exergy loss between this temperature level and the CM load temperature(s) be minimized by the process configuration choices. This paper will present, compare and discuss several possible helium distribution process arrangements to support the CM loads.

Ganni, V.; Knudsen, P. [Thomas Jefferson National Accelerator Facility (JLab), Newport News, VA 23606 (United States)

2014-01-29T23:59:59.000Z

495

Pipeline gas pressure reduction with refrigeration generation  

SciTech Connect (OSTI)

The high pressure of pipeline gas is reduced to the low pressure of a distribution system with simultaneous generation of refrigeration by passing the gas through two successive centrifugal compressors driven by two turbo-expanders in which the compressed gas is expanded to successively lower pressures. Refrigeration is recovered from the gas as it leaves each turbo-expander. Methanol is injected into the pipeline gas before it is expanded to prevent ice formation. Aqueous methanol condensate separated from the expanded gas is distilled for the recovery and reuse of methanol.

Markbreiter, S. J.; Schorr, H. P.

1985-06-11T23:59:59.000Z

496

Reducing the Carbon Footprint of Commercial Refrigeration Systems Using Life Cycle Climate Performance Analysis: From System Design to Refrigerant Options  

SciTech Connect (OSTI)

In this paper, Life Cycle Climate Performance (LCCP) analysis is used to estimate lifetime direct and indirect carbon dioxide equivalent gas emissions of various refrigerant options and commercial refrigeration system designs, including the multiplex DX system with various hydrofluorocarbon (HFC) refrigerants, the HFC/R744 cascade system incorporating a medium-temperature R744 secondary loop, and the transcritical R744 booster system. The results of the LCCP analysis are presented, including the direct and indirect carbon dioxide equivalent emissions for each refrigeration system and refrigerant option. Based on the results of the LCCP analysis, recommendations are given for the selection of low GWP replacement refrigerants for use in existing commercial refrigeration systems, as well as for the selection of commercial refrigeration system designs with low carbon dioxide equivalent emissions, suitable for new installations.

Fricke, Brian A [ORNL] [ORNL; Abdelaziz, Omar [ORNL] [ORNL; Vineyard, Edward Allan [ORNL] [ORNL

2013-01-01T23:59:59.000Z

497

Evaporative system for water and beverage refrigeration in hot countries  

E-Print Network [OSTI]

Evaporative system for water and beverage refrigeration in hot countries A Saleh1 and MA Al-Nimr2 1 Abstract: The present study proposes an evaporative refrigerating system used to keep water or other are found to be consistent with the available literature data. Keywords: evaporative refrigeration, heat

498

Control method for mixed refrigerant based natural gas liquefier  

DOE Patents [OSTI]

In a natural gas liquefaction system having a refrigerant storage circuit, a refrigerant circulation circuit in fluid communication with the refrigerant storage circuit, and a natural gas liquefaction circuit in thermal communication with the refrigerant circulation circuit, a method for liquefaction of natural gas in which pressure in the refrigerant circulation circuit is adjusted to below about 175 psig by exchange of refrigerant with the refrigerant storage circuit. A variable speed motor is started whereby operation of a compressor is initiated. The compressor is operated at full discharge capacity. Operation of an expansion valve is initiated whereby suction pressure at the suction pressure port of the compressor is maintained below about 30 psig and discharge pressure at the discharge pressure port of the compressor is maintained below about 350 psig. Refrigerant vapor is introduced from the refrigerant holding tank into the refrigerant circulation circuit until the suction pressure is reduced to below about 15 psig, after which flow of the refrigerant vapor from the refrigerant holding tank is terminated. Natural gas is then introduced into a natural gas liquefier, resulting in liquefaction of the natural gas.

Kountz, Kenneth J. (Palatine, IL); Bishop, Patrick M. (Chicago, IL)

2003-01-01T23:59:59.000Z

499

Feasibility of Solar-Assisted Refrigerated Transport in Australia  

E-Print Network [OSTI]

systems. Keywords: refrigeration, transport, photovoltaics, economics. 1 #12;B. Elliston, M. Dennis) modules to minimise the use of diesel generation in refrigerated transport. Sub- sequently, UK supermarket. This report investigates the merit of retrofitting a PV system to assist refrigerated trailers in Australian

500

Form Date 4/4/01 Refrigerant Service Order Form  

E-Print Network [OSTI]

Recovery Unit ID # : Added Lbs oz Lbs oz Lbs oz Startup Charge Net Refrigerant Added: Lbs oz Parts UsedForm Date 4/4/01 Refrigerant Service Order Form Service ID: Owner: Work Order #: Building: Date: Issued: Completed: Equipment ID: Technicians: Location: Model: Manufact: Serial #: Refrigerant Type

Russell, Lynn