Powered by Deep Web Technologies
Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Comprehensive Municipal Solid Waste Management, Resource Recovery...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Municipal Solid Waste Management, Resource Recovery, and Conservation Act (Texas) Comprehensive Municipal Solid Waste Management, Resource Recovery, and Conservation...

2

Municipal Solid Waste:  

U.S. Energy Information Administration (EIA) Indexed Site

Methodology for Allocating Municipal Solid Waste Methodology for Allocating Municipal Solid Waste to Biogenic and Non-Biogenic Energy May 2007 Energy Information Administration Office of Coal, Nuclear, Electric and Alternate Fuels U.S. Department of Energy Washington, DC 20585 This report was prepared by the Energy Information Administration, the independent statistical and analytical agency within the U.S. Department of Energy. The information contained herein should be attributed to the Energy Information Administration and should not be construed as advocating or reflecting any policy of the Department of Energy or any other organization. Contact This report was prepared by staff of the Renewable Information Team, Coal, Nuclear, and Renewables Division, Office of Coal, Nuclear, Electric and Alternate Fuels.

3

Municipal Solid Waste | Open Energy Information  

Open Energy Info (EERE)

Municipal Solid Waste Jump to: navigation, search TODO: Add description List of Municipal Solid Waste Incentives Retrieved from "http:en.openei.orgwindex.php?titleMunicipalSo...

4

An Environment Friendly Energy Recovery Technology: Municipal Solid Waste Gasification  

Science Conference Proceedings (OSTI)

Energy from waste, is a perspective source to replace fossil fuels in the future, municipal solid waste (MSW) gasification is a new technique for waste treatment. MSW can be combusted directly to generate heat and electricity, and by means of gasification ... Keywords: municipal solid waste, gasification, incineration

Lei Ma; Chuanhua Liao; Yuezhao Zhu; Haijun Chen; Yanghuiqin Ding

2011-01-01T23:59:59.000Z

5

Characteristics Of Fresh Municipal Solid Waste.  

E-Print Network (OSTI)

??Hossain, Sahadat The characteristics of fresh municipal solid waste (MSW) are critical in planning, designing, operating or upgrading solid waste management systems. Physical composition, moisture… (more)

Taufiq, Tashfeena

2010-01-01T23:59:59.000Z

6

List of Municipal Solid Waste Incentives | Open Energy Information  

Open Energy Info (EERE)

Waste Incentives Waste Incentives Jump to: navigation, search The following contains the list of 172 Municipal Solid Waste Incentives. CSV (rows 1 - 172) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Advanced Clean Energy Project Grants (Texas) State Grant Program Texas Commercial Industrial Utility Biomass Municipal Solid Waste No Advanced Energy Fund (Ohio) Public Benefits Fund Ohio Commercial Industrial Institutional Residential Utility Biomass CHP/Cogeneration Fuel Cells Fuel Cells using Renewable Fuels Geothermal Electric Hydroelectric energy Landfill Gas Microturbines Municipal Solid Waste Photovoltaics Solar Space Heat Solar Thermal Electric Solar Water Heat Wind energy Yes Alternative Energy Law (AEL) (Iowa) Renewables Portfolio Standard Iowa Investor-Owned Utility Anaerobic Digestion

7

Municipal Solid Waste in The United States  

E-Print Network (OSTI)

2005 Facts and Figures Municipal Solid Waste in The United States #12;United States Environmental Protection Agency Office of Solid Waste (5306P) EPA530-R-06-011 October 2006 www.epa.gov #12;MUNICIPAL SOLID WASTE IN THE UNITED STATES: 2005 FACTS AND FIGURES Table of Contents Chapter Page EXECUTIVE

Barlaz, Morton A.

8

Methodology for Allocating Municipal Solid Waste to Biogenic and Non-Biogenic Energy  

Reports and Publications (EIA)

This report summarizes the methodology used to split the heat content of municipal solid waste (MSW) into its biogenic and non-biogenic shares.

Marie LaRiviere

2007-05-14T23:59:59.000Z

9

Solid-State Lighting: 2010 Municipal Consortium Southwest Region Workshop  

NLE Websites -- All DOE Office Websites (Extended Search)

0 Municipal Consortium 0 Municipal Consortium Southwest Region Workshop Materials to someone by E-mail Share Solid-State Lighting: 2010 Municipal Consortium Southwest Region Workshop Materials on Facebook Tweet about Solid-State Lighting: 2010 Municipal Consortium Southwest Region Workshop Materials on Twitter Bookmark Solid-State Lighting: 2010 Municipal Consortium Southwest Region Workshop Materials on Google Bookmark Solid-State Lighting: 2010 Municipal Consortium Southwest Region Workshop Materials on Delicious Rank Solid-State Lighting: 2010 Municipal Consortium Southwest Region Workshop Materials on Digg Find More places to share Solid-State Lighting: 2010 Municipal Consortium Southwest Region Workshop Materials on AddThis.com... Conferences & Meetings Presentations Publications

10

Solid-State Lighting: 2011 Municipal Consortium Southeast Region Workshop  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Municipal Consortium 1 Municipal Consortium Southeast Region Workshop Materials to someone by E-mail Share Solid-State Lighting: 2011 Municipal Consortium Southeast Region Workshop Materials on Facebook Tweet about Solid-State Lighting: 2011 Municipal Consortium Southeast Region Workshop Materials on Twitter Bookmark Solid-State Lighting: 2011 Municipal Consortium Southeast Region Workshop Materials on Google Bookmark Solid-State Lighting: 2011 Municipal Consortium Southeast Region Workshop Materials on Delicious Rank Solid-State Lighting: 2011 Municipal Consortium Southeast Region Workshop Materials on Digg Find More places to share Solid-State Lighting: 2011 Municipal Consortium Southeast Region Workshop Materials on AddThis.com... Conferences & Meetings Presentations Publications

11

Conversion of municipal solid waste to hydrogen  

Science Conference Proceedings (OSTI)

LLNL and Texaco are cooperatively developing a physical and chemical treatment method for the conversion of municipal solid waste (MSW) to hydrogen via the steps of hydrothermal pretreatment, gasification and purification. LLNL`s focus has been on hydrothermal pretreatment of MSW in order to prepare a slurry of suitable viscosity and heating value to allow efficient and economical gasification and hydrogen production. The project has evolved along 3 parallel paths: laboratory scale experiments, pilot scale processing, and process modeling. Initial laboratory-scale MSW treatment results (e.g., viscosity, slurry solids content) over a range of temperatures and times with newspaper and plastics will be presented. Viscosity measurements have been correlated with results obtained at MRL. A hydrothermal treatment pilot facility has been rented from Texaco and is being reconfigured at LLNL; the status of that facility and plans for initial runs will be described. Several different operational scenarios have been modeled. Steady state processes have been modeled with ASPEN PLUS; consideration of steam injection in a batch mode was handled using continuous process modules. A transient model derived from a general purpose packed bed model is being developed which can examine the aspects of steam heating inside the hydrothermal reactor vessel. These models have been applied to pilot and commercial scale scenarios as a function of MSW input parameters and have been used to outline initial overall economic trends. Part of the modeling, an overview of the MSW gasification process and the modeling of the MSW as a process material, was completed by a DOE SERS (Science and Engineering Research Semester) student. The ultimate programmatic goal is the technical demonstration of the gasification of MSW to hydrogen at the laboratory and pilot scale and the economic analysis of the commercial feasibility of such a process.

Richardson, J.H.; Rogers, R.S.; Thorsness, C.B. [and others

1995-04-01T23:59:59.000Z

12

Hydrogen production from municipal solid waste  

DOE Green Energy (OSTI)

We have modified a Municipal Solid Waste (MSW) hydrothermal pretreatment pilot plant for batch operation and blowdown of the treated batch to low pressure. We have also assembled a slurry shearing pilot plant for particle size reduction. Waste paper and a mixture of waste paper/polyethylene plastic have been run in the pilot plant with a treatment temperature of 275{degrees}C. The pilot-plant products have been used for laboratory studies at LLNL. The hydrothermal/shearing pilot plants have produced acceptable slurries for gasification tests from a waste paper feedstock. Work is currently underway with combined paper/plastic feedstocks. When the assembly of the Research Gasification Unit at Texaco (feed capacity approximately 3/4-ton/day) is complete (4th quarter of FY96), gasification test runs will commence. Laboratory work on slurry samples during FY96 has provided correlations between slurry viscosity and hydrothermal treatment temperature, degree of shearing, and the presence of surfactants and admixed plastics. To date, pumpable slurries obtained from an MSW surrogate mixture of treated paper and plastic have shown heating values in the range 13-15 MJ/kg. Our process modeling has quantified the relationship between slurry heating value and hydrogen yield. LLNL has also performed a preliminary cost analysis of the process with the slurry heating value and the MSW tipping fee as parameters. This analysis has shown that the overall process with a 15 MJ/kg slurry gasifier feed can compete with coal-derived hydrogen with the assumption that the tipping fee is of the order $50/ton.

Wallman, P.H.; Richardson, J.H.; Thorsness, C.B. [and others

1996-06-28T23:59:59.000Z

13

Solid-State Lighting: 2011 Municipal Consortium North Central Region  

NLE Websites -- All DOE Office Websites (Extended Search)

2011 Municipal Consortium North 2011 Municipal Consortium North Central Region Workshop Materials to someone by E-mail Share Solid-State Lighting: 2011 Municipal Consortium North Central Region Workshop Materials on Facebook Tweet about Solid-State Lighting: 2011 Municipal Consortium North Central Region Workshop Materials on Twitter Bookmark Solid-State Lighting: 2011 Municipal Consortium North Central Region Workshop Materials on Google Bookmark Solid-State Lighting: 2011 Municipal Consortium North Central Region Workshop Materials on Delicious Rank Solid-State Lighting: 2011 Municipal Consortium North Central Region Workshop Materials on Digg Find More places to share Solid-State Lighting: 2011 Municipal Consortium North Central Region Workshop Materials on AddThis.com... Conferences & Meetings

14

Solid-State Lighting: Municipal Solid-State Street Lighting Consortium  

NLE Websites -- All DOE Office Websites (Extended Search)

Municipal Solid-State Street Municipal Solid-State Street Lighting Consortium Kickoff Webcast to someone by E-mail Share Solid-State Lighting: Municipal Solid-State Street Lighting Consortium Kickoff Webcast on Facebook Tweet about Solid-State Lighting: Municipal Solid-State Street Lighting Consortium Kickoff Webcast on Twitter Bookmark Solid-State Lighting: Municipal Solid-State Street Lighting Consortium Kickoff Webcast on Google Bookmark Solid-State Lighting: Municipal Solid-State Street Lighting Consortium Kickoff Webcast on Delicious Rank Solid-State Lighting: Municipal Solid-State Street Lighting Consortium Kickoff Webcast on Digg Find More places to share Solid-State Lighting: Municipal Solid-State Street Lighting Consortium Kickoff Webcast on AddThis.com... Conferences & Meetings

15

Solid-State Lighting: Text-Alternative Version: Municipal Solid-State  

NLE Websites -- All DOE Office Websites (Extended Search)

Municipal Solid-State Street Lighting Consortium Kickoff to someone by Municipal Solid-State Street Lighting Consortium Kickoff to someone by E-mail Share Solid-State Lighting: Text-Alternative Version: Municipal Solid-State Street Lighting Consortium Kickoff on Facebook Tweet about Solid-State Lighting: Text-Alternative Version: Municipal Solid-State Street Lighting Consortium Kickoff on Twitter Bookmark Solid-State Lighting: Text-Alternative Version: Municipal Solid-State Street Lighting Consortium Kickoff on Google Bookmark Solid-State Lighting: Text-Alternative Version: Municipal Solid-State Street Lighting Consortium Kickoff on Delicious Rank Solid-State Lighting: Text-Alternative Version: Municipal Solid-State Street Lighting Consortium Kickoff on Digg Find More places to share Solid-State Lighting: Text-Alternative Version: Municipal Solid-State Street Lighting Consortium Kickoff on

16

Municipal solid waste generation in municipalities: Quantifying impacts of household structure, commercial waste and domestic fuel  

Science Conference Proceedings (OSTI)

Waste management planning requires reliable data concerning waste generation, influencing factors on waste generation and forecasts of waste quantities based on facts. This paper aims at identifying and quantifying differences between different municipalities' municipal solid waste (MSW) collection quantities based on data from waste management and on socio-economic indicators. A large set of 116 indicators from 542 municipalities in the Province of Styria was investigated. The resulting regression model included municipal tax revenue per capita, household size and the percentage of buildings with solid fuel heating systems. The model explains 74.3% of the MSW variation and the model assumptions are met. Other factors such as tourism, home composting or age distribution of the population did not significantly improve the model. According to the model, 21% of MSW collected in Styria was commercial waste and 18% of the generated MSW was burned in domestic heating systems. While the percentage of commercial waste is consistent with literature data, practically no literature data are available for the quantity of MSW burned, which seems to be overestimated by the model. The resulting regression model was used as basis for a waste prognosis model (Beigl and Lebersorger, in preparation).

Lebersorger, S. [Institute of Waste Management, Department of Water, Atmosphere and Environment, University of Natural Resources and Life Sciences, Vienna, Muthgasse 107, A-1190 Wien (Austria); Beigl, P., E-mail: peter.beigl@boku.ac.at [Institute of Waste Management, Department of Water, Atmosphere and Environment, University of Natural Resources and Life Sciences, Vienna, Muthgasse 107, A-1190 Wien (Austria)

2011-09-15T23:59:59.000Z

17

Environmental impact on municipal solid waste management system in Chaiyaphum  

Science Conference Proceedings (OSTI)

Continually increasing amount of municipal solid waste (MSW) and the limited capacity of the existing waste management system are serious problems that Chaiyaphum municipality must deal with. The optimal waste management system should be adopted. Explicit ... Keywords: decision making, environmental evaluation, life cycle assessment, municipal solid waste

S. Piyaphant; K. Prayong

2011-10-01T23:59:59.000Z

18

Solid-State Lighting: DOE Municipal Solid-State Street Lighting Consortium  

NLE Websites -- All DOE Office Websites (Extended Search)

Market-Based Programs Printable Version Share this resource Send a link to Solid-State Lighting: DOE Municipal Solid-State Street Lighting Consortium to someone by E-mail Share Solid-State Lighting: DOE Municipal Solid-State Street Lighting Consortium on Facebook Tweet about Solid-State Lighting: DOE Municipal Solid-State Street Lighting Consortium on Twitter Bookmark Solid-State Lighting: DOE Municipal Solid-State Street Lighting Consortium on Google Bookmark Solid-State Lighting: DOE Municipal Solid-State Street Lighting Consortium on Delicious Rank Solid-State Lighting: DOE Municipal Solid-State Street Lighting Consortium on Digg Find More places to share Solid-State Lighting: DOE Municipal Solid-State Street Lighting Consortium on AddThis.com... LED Lighting Facts

19

Municipal Solid Waste Resources and Technologies | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Municipal Solid Waste Resources and Technologies Municipal Solid Waste Resources and Technologies Municipal Solid Waste Resources and Technologies October 7, 2013 - 9:28am Addthis Black and white photo of a bulldozer pushing a large mound of trash in a landfill. The National Renewable Energy Laboratory's high-solids digester converts wastes to biogas and compost for energy production. This page provides a brief overview of municipal solid waste energy resources and technologies supplemented by specific information to apply waste to energy within the Federal sector. Overview Municipal solid waste, also known as waste to energy, generates electricity by burning solid waste as fuel. This generates renewable electricity while also incinerating landfill and other municipal waste products such as trash, yard clippings and debris, furniture, food scraps, and other

20

Municipal Solid Waste Resources and Technologies | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Municipal Solid Waste Resources and Technologies Municipal Solid Waste Resources and Technologies Municipal Solid Waste Resources and Technologies October 7, 2013 - 9:28am Addthis Black and white photo of a bulldozer pushing a large mound of trash in a landfill. The National Renewable Energy Laboratory's high-solids digester converts wastes to biogas and compost for energy production. This page provides a brief overview of municipal solid waste energy resources and technologies supplemented by specific information to apply waste to energy within the Federal sector. Overview Municipal solid waste, also known as waste to energy, generates electricity by burning solid waste as fuel. This generates renewable electricity while also incinerating landfill and other municipal waste products such as trash, yard clippings and debris, furniture, food scraps, and other

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Solid-State Lighting: Webcast: Municipal Solid-State Street Lighting  

NLE Websites -- All DOE Office Websites (Extended Search)

Webcast: Municipal Solid-State Webcast: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool to someone by E-mail Share Solid-State Lighting: Webcast: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool on Facebook Tweet about Solid-State Lighting: Webcast: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool on Twitter Bookmark Solid-State Lighting: Webcast: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool on Google Bookmark Solid-State Lighting: Webcast: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool on Delicious Rank Solid-State Lighting: Webcast: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool on Digg

22

Municipal solid-waste management in Istanbul  

SciTech Connect

Istanbul, with a population of around 13 million people, is located between Europe and Asia and is the biggest city in Turkey. Metropolitan Istanbul produces about 14,000 tons of solid waste per day. The aim of this study was to assess the situation of municipal solid-waste (MSW) management in Istanbul. This was achieved by reviewing the quantity and composition of waste produced in Istanbul. Current requirements and challenges in relation to the optimization of Istanbul's MSW collection and management system are also discussed, and several suggestions for solving the problems identified are presented. The recovery of solid waste from the landfills, as well as the amounts of landfill-generated biogas and electricity, were evaluated. In recent years, MSW management in Istanbul has improved because of strong governance and institutional involvement. However, efforts directed toward applied research are still required to enable better waste management. These efforts will greatly support decision making on the part of municipal authorities. There remains a great need to reduce the volume of MSW in Istanbul.

Kanat, Gurdal, E-mail: gkanat@gmail.co [Yildiz Teknik Universitesi Cevre Muh Bolumu, 34220 Davutpasa-Esenler, Istanbul (Turkey)

2010-08-15T23:59:59.000Z

23

Solid-State Lighting: Municipal Consortium Annual Meeting Presentations and  

NLE Websites -- All DOE Office Websites (Extended Search)

Information Information Resources Printable Version Share this resource Send a link to Solid-State Lighting: Municipal Consortium Annual Meeting Presentations and Materials-Phoenix, AZ to someone by E-mail Share Solid-State Lighting: Municipal Consortium Annual Meeting Presentations and Materials-Phoenix, AZ on Facebook Tweet about Solid-State Lighting: Municipal Consortium Annual Meeting Presentations and Materials-Phoenix, AZ on Twitter Bookmark Solid-State Lighting: Municipal Consortium Annual Meeting Presentations and Materials-Phoenix, AZ on Google Bookmark Solid-State Lighting: Municipal Consortium Annual Meeting Presentations and Materials-Phoenix, AZ on Delicious Rank Solid-State Lighting: Municipal Consortium Annual Meeting Presentations and Materials-Phoenix, AZ on Digg

24

Solid-State Lighting: 2011 Municipal Consortium North Central Region  

NLE Websites -- All DOE Office Websites (Extended Search)

Consortium North Consortium North Central Region Workshop Materials to someone by E-mail Share Solid-State Lighting: 2011 Municipal Consortium North Central Region Workshop Materials on Facebook Tweet about Solid-State Lighting: 2011 Municipal Consortium North Central Region Workshop Materials on Twitter Bookmark Solid-State Lighting: 2011 Municipal Consortium North Central Region Workshop Materials on Google Bookmark Solid-State Lighting: 2011 Municipal Consortium North Central Region Workshop Materials on Delicious Rank Solid-State Lighting: 2011 Municipal Consortium North Central Region Workshop Materials on Digg Find More places to share Solid-State Lighting: 2011 Municipal Consortium North Central Region Workshop Materials on AddThis.com... LED Lighting Facts CALiPER Program

25

Solid-State Lighting: 2011 Municipal Consortium Northeast Region Workshop  

NLE Websites -- All DOE Office Websites (Extended Search)

Northeast Region Workshop Materials to someone by E-mail Northeast Region Workshop Materials to someone by E-mail Share Solid-State Lighting: 2011 Municipal Consortium Northeast Region Workshop Materials on Facebook Tweet about Solid-State Lighting: 2011 Municipal Consortium Northeast Region Workshop Materials on Twitter Bookmark Solid-State Lighting: 2011 Municipal Consortium Northeast Region Workshop Materials on Google Bookmark Solid-State Lighting: 2011 Municipal Consortium Northeast Region Workshop Materials on Delicious Rank Solid-State Lighting: 2011 Municipal Consortium Northeast Region Workshop Materials on Digg Find More places to share Solid-State Lighting: 2011 Municipal Consortium Northeast Region Workshop Materials on AddThis.com... LED Lighting Facts CALiPER Program Standards Development Technical Information Network

26

Solid-State Lighting: Municipal Consortium LED Street Lighting Workshop  

NLE Websites -- All DOE Office Websites (Extended Search)

Los Angeles, CA to someone Los Angeles, CA to someone by E-mail Share Solid-State Lighting: Municipal Consortium LED Street Lighting Workshop Presentations and Materials-Los Angeles, CA on Facebook Tweet about Solid-State Lighting: Municipal Consortium LED Street Lighting Workshop Presentations and Materials-Los Angeles, CA on Twitter Bookmark Solid-State Lighting: Municipal Consortium LED Street Lighting Workshop Presentations and Materials-Los Angeles, CA on Google Bookmark Solid-State Lighting: Municipal Consortium LED Street Lighting Workshop Presentations and Materials-Los Angeles, CA on Delicious Rank Solid-State Lighting: Municipal Consortium LED Street Lighting Workshop Presentations and Materials-Los Angeles, CA on Digg Find More places to share Solid-State Lighting: Municipal Consortium

27

Solid-State Lighting: 2011 Municipal Consortium Northwest Region Workshop  

NLE Websites -- All DOE Office Websites (Extended Search)

Northwest Region Workshop Materials to someone by E-mail Northwest Region Workshop Materials to someone by E-mail Share Solid-State Lighting: 2011 Municipal Consortium Northwest Region Workshop Materials on Facebook Tweet about Solid-State Lighting: 2011 Municipal Consortium Northwest Region Workshop Materials on Twitter Bookmark Solid-State Lighting: 2011 Municipal Consortium Northwest Region Workshop Materials on Google Bookmark Solid-State Lighting: 2011 Municipal Consortium Northwest Region Workshop Materials on Delicious Rank Solid-State Lighting: 2011 Municipal Consortium Northwest Region Workshop Materials on Digg Find More places to share Solid-State Lighting: 2011 Municipal Consortium Northwest Region Workshop Materials on AddThis.com... LED Lighting Facts CALiPER Program Standards Development Technical Information Network

28

Federal Energy Management Program: Municipal Solid Waste Resources...  

NLE Websites -- All DOE Office Websites (Extended Search)

The National Renewable Energy Laboratory's high-solids digester converts wastes to biogas and compost for energy production. This page provides a brief overview of municipal...

29

UTILIZATION OF MUNICIPAL SOLID WASTE COMPOST IN HORTICULTURE.  

E-Print Network (OSTI)

??Composting of municipal solid waste (MSW) has long been considered an attractive waste management tool for effective reduction of waste volume and beneficial utilization of… (more)

Lu, Wenliang

2008-01-01T23:59:59.000Z

30

Solid-State Lighting: Text-Alternative Version: Municipal Solid-State  

NLE Websites -- All DOE Office Websites (Extended Search)

Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool Webcast to someone by E-mail Share Solid-State Lighting: Text-Alternative Version: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool Webcast on Facebook Tweet about Solid-State Lighting: Text-Alternative Version: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool Webcast on Twitter Bookmark Solid-State Lighting: Text-Alternative Version: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool Webcast on Google Bookmark Solid-State Lighting: Text-Alternative Version: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool Webcast on Delicious Rank Solid-State Lighting: Text-Alternative Version: Municipal

31

Co-firing coal and municipal solid waste  

SciTech Connect

The aim of this study was to experimentally investigate how different the organic fraction of municipal solid waste (OFMSW) or municipal solid waste (MSW) utilizing strategies affects the gas emission in simple fluidized bed combustion (FBC) of biomass. In this study, ground OFMSW and pulverized coal (PC) were used for co-firing tests. The tests were carried out in a bench-scale bubbling FBC. Coal and bio-waste fuels are quite different in composition. Ash composition of the bio-waste fuels is fundamentally different from ash composition of the coal. Chlorine (Cl) in the MSW may affect operation by corrosion. Ash deposits reduce heat transfer and also may result in severe corrosion at high temperatures. Nitrogen (N) and carbon ) assessments can play an important role in a strategy to control carbon dioxide (CO{sub 2}) and nitrogen oxide (NOx) emissions while raising revenue. Regulations such as subsidies for oil, liquid petroleum gas (LPG) for natural gas powered vehicles, and renewables, especially biomass lines, to reduce emissions may be more cost-effective than assessments. Research and development (RD) resources are driven by energy policy goals and can change the competitiveness of renewables, especially solid waste. The future supply of co-firing depends on energy prices and technical progress, both of which are driven by energy policy priorities.

Demirbas, A. [Sila Science, Trabzon (Turkey)

2008-07-01T23:59:59.000Z

32

Mathematical Models in Municipal Solid Waste Management  

E-Print Network (OSTI)

Two mathematical models developed as tools for solid waste planners in decisions concerning the overall management of solid waste in a municipality are described. The models have respectively been formulated as integer and mixed integer linear programming problems. The choice between the two models from the practical point of view depends on the user and the technology used. One user may prefer to measure the transportation costs in terms of costs per trip made from the waste source, in which case the first model is more appropriate. In this case we replace the coefficients of the decision variables in the objective function with the total cost per trip from the waste collection point. At the same time, instead of measuring the amount of waste using the number of trucks used multiplied by their capacities, continuous variables can be introduced to measure directly the amount of waste that goes to the plants and landfills. The integer linear problem is then transformed into a mixed integer problem that gives better total cost estimates and more precise waste amount measurements, but measuring transportation costs in terms of costs per trip. For instance, at the moment the first model is more relevant to the Ugandan situation, where the technology to measure waste as it is carried away from the waste sources is not available. Another user may prefer to measure the transportation costs in terms of costs per unit mass of

Michael K. Nganda

2007-01-01T23:59:59.000Z

33

Municipal solid waste management in Beijing City  

Science Conference Proceedings (OSTI)

This paper presents an overview of municipal solid waste (MSW) management in Beijing City. Beijing, the capital of China, has a land area of approximately 1368.32 km{sup 2} with an urban population of about 13.33 million in 2006. Over the past three decades, MSW generation in Beijing City has increased tremendously from 1.04 million tons in 1978 to 4.134 million tons in 2006. The average generation rate of MSW in 2006 was 0.85 kg/capita/day. Food waste comprised 63.39%, followed by paper (11.07%), plastics (12.7%) and dust (5.78%). While all other wastes including tiles, textiles, glass, metals and wood accounted for less than 3%. Currently, 90% of MSW generated in Beijing is landfilled, 8% is incinerated and 2% is composted. Source separation collection, as a waste reduction method, has been carried out in a total of 2255 demonstration residential and commercial areas (covering about 4.7 million people) up to the end of 2007. Demonstration districts should be promoted over a wider range instead of demonstration communities. The capacity of transfer stations and treatment plants is an urgent problem as these sites are seriously overloaded. These problems should first be solved by constructing more sites and converting to new treatment technologies. Improvements in legislation, public education and the management of waste pickers are problematic issues which need to be addressed.

Li Zhenshan [Department of Environmental Engineering, Peking University, Key Laboratory of Water and Sediment Sciences, Ministry of Education, No. 5, Yi Heyuan Road, Haidian District, Beijing 100871 (China); Key Laboratory for Environmental and Urban Sciences, Shenzhen Graduate School, Peking University, Shenzhen 518055 (China)], E-mail: lizhenshan@pku.edu.cn; Yang Lei [Department of Environmental Engineering, Peking University, Key Laboratory of Water and Sediment Sciences, Ministry of Education, No. 5, Yi Heyuan Road, Haidian District, Beijing 100871 (China); Qu XiaoYan [Key Laboratory for Environmental and Urban Sciences, Shenzhen Graduate School, Peking University, Shenzhen 518055 (China); Sui Yumei [Department of Environmental Engineering, Peking University, Key Laboratory of Water and Sediment Sciences, Ministry of Education, No. 5, Yi Heyuan Road, Haidian District, Beijing 100871 (China)

2009-09-15T23:59:59.000Z

34

Information Resources: Municipal Solid-State Street Lighting...  

NLE Websites -- All DOE Office Websites (Extended Search)

6, 2010 webcast served as the first official meeting of the new DOE Municipal Solid-State Street Lighting Consortium. Ed Smalley of Seattle City Light and Bruce Kinzey of Pacific...

35

Solid-State Lighting: Municipal Consortium LED Street Lighting...  

NLE Websites -- All DOE Office Websites (Extended Search)

Boston, MA to someone by E-mail Share Solid-State Lighting: Municipal Consortium LED Street Lighting Workshop Presentations and Materials-Boston, MA on Facebook Tweet about...

36

Solid-State Lighting: Municipal Consortium LED Street Lighting...  

NLE Websites -- All DOE Office Websites (Extended Search)

Dallas, TX to someone by E-mail Share Solid-State Lighting: Municipal Consortium LED Street Lighting Workshop Presentations and Materials-Dallas, TX on Facebook Tweet about...

37

Municipal waste incineration; An environmentally benign energy source for district heating  

SciTech Connect

Municipal solid waste should be regarded as a good fuel. Emissions from solid waste incineration can be kept within any reasonable limit. Compared with fossil fuels, waste can be regarded as a renewable source of energy that does not contribute to the greenhouse effect. Finally, waste incineration for district heating can be very economical.

Astrand, L.E. (Uppsala Energi AB, Uppsala (SE))

1990-01-01T23:59:59.000Z

38

Information Resources: Webcast: Municipal Solid-State Street Lighting  

NLE Websites -- All DOE Office Websites (Extended Search)

Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool This April 3, 2012 webcast presented information about the Retrofit Financial Analysis Tool developed by DOE"s Municipal Solid-State Street Lighting Consortium. Doug Elliott of Pacific Northwest National Laboratory provided a guided walk-through of what the tool can do and how to use it to evaluate costs and benefits associated with converting to LED street and roadway lighting. The webcast showed how city and other government agencies, utilities, finance and budget offices, and energy efficiency organizations can use the tool to compute annualized energy-cost savings, maintenance savings, greenhouse gas reductions, net present value, and simple payback, which can be helpful when putting together construction and conservation grant applications, as well as for preparing budgets and comparing incumbent costs to new costs.

39

Oklahoma Municipal Power Authority - Geothermal Heat Pump Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Oklahoma Municipal Power Authority - Geothermal Heat Pump Rebate Oklahoma Municipal Power Authority - Geothermal Heat Pump Rebate Program Oklahoma Municipal Power Authority - Geothermal Heat Pump Rebate Program < Back Eligibility Agricultural Commercial Industrial Residential Maximum Rebate 1,000/ton Program Info Funding Source American Recovery and Reinvestment Act of 2009 State Oklahoma Program Type Utility Rebate Program Rebate Amount $800 - $1,000/ton Provider Oklahoma Municipal Power Authority Program funds currently exhausted, additional funds have been requested. Visit the program website for the most up to date information on fund availability and to register for the waiting list for this program. The Oklahoma Municipal Power Authority (OMPA) and the Oklahoma Department of Commerce currently offer the Oklahoma Comfort Program for geothermal

40

Heat capacities of elastic solids  

E-Print Network (OSTI)

The work function is embedded in the equation describing the relationship between the constant volume and constant pressure heat capacities. The modification of the work function results that the relationship between these quantities must be changed accordingly. Using the newly derived work functions of elastic solids the description of the heat capacities and the relationship between the heat capacities are given for solid phase.

Garai, J

2005-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Ouray Municipal Pool Space Heating Low Temperature Geothermal Facility |  

Open Energy Info (EERE)

Ouray Municipal Pool Space Heating Low Temperature Geothermal Facility Ouray Municipal Pool Space Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Ouray Municipal Pool Space Heating Low Temperature Geothermal Facility Facility Ouray Municipal Pool Sector Geothermal energy Type Space Heating Location Ouray, Colorado Coordinates 38.0227716°, -107.6714487° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

42

Municipal solid waste management in Malaysia: Practices and challenges  

Science Conference Proceedings (OSTI)

Rapid economic development and population growth, inadequate infrastructure and expertise, and land scarcity make the management of municipal solid waste become one of Malaysia's most critical environmental issues. The study is aimed at evaluating the generation, characteristics, and management of solid waste in Malaysia based on published information. In general, the per capita generation rate is about 0.5-0.8 kg/person/day in which domestic waste is the primary source. Currently, solid waste is managed by the Ministry of Housing and Local Government, with the participation of the private sector. A new institutional and legislation framework has been structured with the objectives to establish a holistic, integrated, and cost-effective solid waste management system, with an emphasis on environmental protection and public health. Therefore, the hierarchy of solid waste management has given the highest priority to source reduction through 3R, intermediate treatment and final disposal.

Manaf, Latifah Abd [Department of Environmental Sciences, Faculty of Environmental Studies, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia)], E-mail: latifah@env.upm.my; Samah, Mohd Armi Abu; Zukki, Nur Ilyana Mohd [Department of Environmental Sciences, Faculty of Environmental Studies, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia)

2009-11-15T23:59:59.000Z

43

Guide to Clean Development Mechanism Projects Related to Municipal Solid  

Open Energy Info (EERE)

Guide to Clean Development Mechanism Projects Related to Municipal Solid Guide to Clean Development Mechanism Projects Related to Municipal Solid Waste Management Jump to: navigation, search Tool Summary Name: A Guide to Clean Development Mechanism Projects Related to Municipal Solid Waste Management Agency/Company /Organization: United Nations Economic and Social Commission for Asia and the Pacific Sector: Energy, Land Focus Area: - Landfill Gas, - Waste to Energy Topics: Implementation, Co-benefits assessment Resource Type: Guide/manual, Lessons learned/best practices Website: www.unescap.org/esd/environment/publications/cdm/Guide.pdf UN Region: Central Asia, Eastern Asia, South-Eastern Asia, "Pacific" is not in the list of possible values (Eastern Africa, Middle Africa, Northern Africa, Southern Africa, Western Africa, Caribbean, Central America, South America, Northern America, Central Asia, Eastern Asia, Southern Asia, South-Eastern Asia, Western Asia, Eastern Europe, Northern Europe, Southern Europe, Western Europe, Australia and New Zealand, Melanesia, Micronesia, Polynesia, Latin America and the Caribbean) for this property.

44

Sustainable recycling of municipal solid waste in developing countries  

SciTech Connect

This research focuses on recycling in developing countries as one form of sustainable municipal solid waste management (MSWM). Twenty-three case studies provided municipal solid waste (MSW) generation and recovery rates and composition for compilation and assessment. The average MSW generation rate was 0.77 kg/person/day, with recovery rates from 5-40%. The waste streams of 19 of these case studies consisted of 0-70% recyclables and 17-80% organics. Qualitative analysis of all 23 case studies identified barriers or incentives to recycling, which resulted in the development of factors influencing recycling of MSW in developing countries. The factors are government policy, government finances, waste characterization, waste collection and segregation, household education, household economics, MSWM (municipal solid waste management) administration, MSWM personnel education, MSWM plan, local recycled-material market, technological and human resources, and land availability. Necessary and beneficial relationships drawn among these factors revealed the collaborative nature of sustainable MSWM. The functionality of the factor relationships greatly influenced the success of sustainable MSWM. A correlation existed between stakeholder involvement and the three dimensions of sustainability: environment, society, and economy. The only factors driven by all three dimensions (waste collection and segregation, MSWM plan, and local recycled-material market) were those requiring the greatest collaboration with other factors.

Troschinetz, Alexis M. [Department of Civil and Environmental Engineering, Sustainable Futures Institute, Michigan Technological University, 1400 Townsend Dr., Houghton, MI 49931 (United States)], E-mail: alexis_troschinetz@yahoo.com; Mihelcic, James R. [Department of Civil and Environmental Engineering, Sustainable Futures Institute, Michigan Technological University, 1400 Townsend Dr., Houghton, MI 49931 (United States)

2009-02-15T23:59:59.000Z

45

Municipal solid waste to electricity in Bangkok, Thailand (prefeasibility study)  

SciTech Connect

Recognizing the problem of municipal waste disposal in Bangkok and the potential for energy recovery, the Royal Government of Thailand requested the US Trade and Development Program (TDP) to provide assistance in conducting an initial assessment of the potential options for managing Bangkok's waste disposal problem. Before undertaking a detailed feasibility study of a relatively attractive option for municipal solid waste (MSW) disposal in Bangkok, the Thai government wanted to determine whether a project for waste disposal and energy recovery could be developed with the involvement of the private sector such that over time the project could be totally owned and operated in the private domain. In response to the request made by the National Energy Administration (NEA) and Bangkok Metropolitan Administration (BMA), TDP asked Engineering and Economics Research Inc. (EER) to send a team of consultants to conduct a definitional study to make a preliminary assessment of a municipal waste solid disposal system which recovers energy in conjunction with the treatment/disposal of waste in an environmentally safe manner. The consultants visited Thailand for a period of 3 weeks and worked with officials from NEA and BMA.

1985-09-01T23:59:59.000Z

46

Process and technological aspects of municipal solid waste gasification. A review  

Science Conference Proceedings (OSTI)

Highlights: Black-Right-Pointing-Pointer Critical assessment of the main commercially available MSW gasifiers. Black-Right-Pointing-Pointer Detailed discussion of the basic features of gasification process. Black-Right-Pointing-Pointer Description of configurations of gasification-based waste-to-energy units. Black-Right-Pointing-Pointer Environmental performance analysis, on the basis of independent sources data. - Abstract: The paper proposes a critical assessment of municipal solid waste gasification today, starting from basic aspects of the process (process types and steps, operating and performance parameters) and arriving to a comparative analysis of the reactors (fixed bed, fluidized bed, entrained bed, vertical shaft, moving grate furnace, rotary kiln, plasma reactor) as well as of the possible plant configurations (heat gasifier and power gasifier) and the environmental performances of the main commercially available gasifiers for municipal solid wastes. The analysis indicates that gasification is a technically viable option for the solid waste conversion, including residual waste from separate collection of municipal solid waste. It is able to meet existing emission limits and can have a remarkable effect on reduction of landfill disposal option.

Arena, Umberto, E-mail: umberto.arena@unina2.it [Department of Environmental Sciences, Second University of Naples, Via A. Vivaldi, 43, 81100 Caserta (Italy)

2012-04-15T23:59:59.000Z

47

Evaluation of mixing systems for biogasification of municipal solid waste  

DOE Green Energy (OSTI)

Two specially selected mixing systems were tested and evaluated to determine how effectively they could prevent the formation of fibrous mats and stringers during the anaerobic digestion of a slurried mixture of preprocessed municipal solid waste and sewage sludge to produce methane gas. The tests were conducted in a modified 10.7-m (35-ft) diameter, nominal 378,000-liter (100,000-gal) capacity concrete vessel in the Franklin, Ohio, environmental complex. Between August 1977 and September 1978, nine tests were conducted with 3:1 and 9:1 solid waste/sewage sludge ratios and with 4, 7, and 10 percent total solids in the feedstock. Though the microbial culture was healthy in most tests, the mixing systems were not effective in preventing excessive fibrous mat and stringer formations. These formations occurred because of the high cellulosic content of the feedstock. The test with the best energy recovery had a gas production of 805 liters/kg of volatile solids destroyed. However, the energy recovered was only 50 percent of the energy available in the solid waste, and only four times greater than the mixing energy expended for that test. The solids accumulations were generally the same for the two mixing systems when they had common test conditions. In all tests, the percent solids for the top level were higher than those for the middle and bottom levels. As the feed ratio and the percent solids in the feedstock were increased, this differential became progressively more pronounced. Moreover, the percent of volatile solids (in a given amount of total solids) for the top level became disproportionately higher than those for the other two levels.

Swartzbaugh, J T; Smith, R B

1979-01-01T23:59:59.000Z

48

Comprehensive Municipal Solid Waste Management, Resource Recovery, and Conservation Act (Texas)  

Energy.gov (U.S. Department of Energy (DOE))

This Act encourages the establishment of regional waste management facilities and the cooperation of local waste management entities in order to streamline the management of municipal solid waste...

49

Recovery of solid fuel from municipal solid waste by hydrothermal treatment using subcritical water  

SciTech Connect

Highlights: Black-Right-Pointing-Pointer Hydrothermal treatment using subcritical water was studied to recover solid fuel from MSW. Black-Right-Pointing-Pointer More than 75% of carbon in MSW was recovered as char. Black-Right-Pointing-Pointer Heating value of char was comparable to that of brown coal and lignite. Black-Right-Pointing-Pointer Polyvinyl chloride was decomposed at 295 Degree-Sign C and 8 MPa and was removed by washing. - Abstract: Hydrothermal treatments using subcritical water (HTSW) such as that at 234 Degree-Sign C and 3 MPa (LT condition) and 295 Degree-Sign C and 8 MPa (HT condition) were investigated to recover solid fuel from municipal solid waste (MSW). Printing paper, dog food (DF), wooden chopsticks, and mixed plastic film and sheets of polyethylene, polypropylene, and polystyrene were prepared as model MSW components, in which polyvinylchloride (PVC) powder and sodium chloride were used to simulate Cl sources. While more than 75% of carbon in paper, DF, and wood was recovered as char under both LT and HT conditions, plastics did not degrade under either LT or HT conditions. The heating value (HV) of obtained char was 13,886-27,544 kJ/kg and was comparable to that of brown coal and lignite. Higher formation of fixed carbon and greater oxygen dissociation during HTSW were thought to improve the HV of char. Cl atoms added as PVC powder and sodium chloride to raw material remained in char after HTSW. However, most Cl originating from PVC was found to converse into soluble Cl compounds during HTSW under the HT condition and could be removed by washing. From these results, the merit of HTSW as a method of recovering solid fuel from MSW is considered to produce char with minimal carbon loss without a drying process prior to HTSW. In addition, Cl originating from PVC decomposes into soluble Cl compound under the HT condition. The combination of HTSW under the HT condition and char washing might improve the quality of char as alternative fuel.

Hwang, In-Hee, E-mail: hwang@eng.hokudai.ac.jp [Laboratory of Solid Waste Disposal Engineering, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060 8628 (Japan); Aoyama, Hiroya; Matsuto, Toshihiko; Nakagishi, Tatsuhiro; Matsuo, Takayuki [Laboratory of Solid Waste Disposal Engineering, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060 8628 (Japan)

2012-03-15T23:59:59.000Z

50

Evaluating the efficiency of municipalities in collecting and processing municipal solid waste: A shared input DEA-model  

SciTech Connect

Highlights: Black-Right-Pointing-Pointer Complexity in local waste management calls for more in depth efficiency analysis. Black-Right-Pointing-Pointer Shared-input Data Envelopment Analysis can provide solution. Black-Right-Pointing-Pointer Considerable room for the Flemish municipalities to improve their cost efficiency. - Abstract: This paper proposed an adjusted 'shared-input' version of the popular efficiency measurement technique Data Envelopment Analysis (DEA) that enables evaluating municipality waste collection and processing performances in settings in which one input (waste costs) is shared among treatment efforts of multiple municipal solid waste fractions. The main advantage of this version of DEA is that it not only provides an estimate of the municipalities overall cost efficiency but also estimates of the municipalities' cost efficiency in the treatment of the different fractions of municipal solid waste (MSW). To illustrate the practical usefulness of the shared input DEA-model, we apply the model to data on 293 municipalities in Flanders, Belgium, for the year 2008.

Rogge, Nicky, E-mail: Nicky.Rogge@hubrussel.be [Hogeschool-Universiteit Brussel (HUBrussel), Center for Business Management Research (CBMR), Warmoesberg 26, 1000 Brussels (Belgium); Katholieke Universiteit Leuven (KULeuven), Faculty of Business and Economics, Naamsestraat 69, 3000 Leuven (Belgium); De Jaeger, Simon [Katholieke Universiteit Leuven (KULeuven), Faculty of Business and Economics, Naamsestraat 69, 3000 Leuven (Belgium); Hogeschool-Universiteit Brussel (HUBrussel), Center for Economics and Corporate Sustainability (CEDON), Warmoesberg 26, 1000 Brussels (Belgium)

2012-10-15T23:59:59.000Z

51

Data summary of municipal solid waste management alternatives  

Science Conference Proceedings (OSTI)

This report provides data for use in evaluating the proven technologies and combinations of technologies that might be considered for managing municipal solid waste (MSW). It covers five major methods for MSW management in common use today: Landfilling; Mass combustion for energy recovery; Production of refuse-derived fuel (RDF); Collection/separation of recyclables; and Composting. It also provides information on three MSW management technologies that are not widely used at present: Anaerobic digestion; Cofiring of MSW with coal; and Gasification/pyrolysis. To the extent possible with available reliable data, the report presents information for each proven MSW technology on: Net energy balances; Environmental releases; and Economics. In addition to data about individual operations, the report presents net energy balances and inventories of environmental releases from selected combined MSW management strategies that use two or more separate operations. The scope of the report extends from the waste's origin (defined as the point at which the waste is set out for collection), through transportation and processing operations, to its final disposition (e.g., recycling and remanufacturing, combustion, or landfilling operations). Data for all operations are presented on a consistent basis: one (1) ton of municipal (i.e., residential, commercial, and institutional) waste at the collection point. Selection of an MSW management plan may be influenced by many factors, in addition to the technical performance and economics of each option.

Not Available

1992-10-01T23:59:59.000Z

52

Process modeling of hydrogen production from municipal solid waste  

DOE Green Energy (OSTI)

The ASPEN PLUS commercial simulation software has been used to develop a process model for a conceptual process to convert municipal solid waste (MSW) to hydrogen. The process consists of hydrothermal treatment of the MSW in water to create a slurry suitable as feedstock for an oxygen blown Texaco gasifier. A method of reducing the complicated MSW feed material to a manageable set of components is outlined along with a framework for modeling the stoichiometric changes associated with the hydrothermal treatment process. Model results indicate that 0.672 kmol/s of hydrogen can be produced from the processing of 30 kg/s (2600 tonne/day) of raw MSW. A number of variations on the basic processing parameters are explored and indicate that there is a clear incentive to reduce the inert fraction in the processed slurry feed and that cofeeding a low value heavy oil may be economically attractive.

Thorsness, C.B.

1995-01-01T23:59:59.000Z

53

Municipal solid waste management in Kolkata, India - A review  

SciTech Connect

Kolkata is one of four metropolitan cities in India. With an area of 187.33 sq km and a population of about 8 million, it generates around 3,000 t d{sup -1} of municipal solid waste (MSW) at a rate of 450-500 g per capita per day. With rapid urbanization as a result of planned and unplanned growth and industrialization, the problems associated with handling MSW have increased at an alarming rate over the past few years. No source segregation arrangement exists; there is only limited (60%) house-to-house collection; and 50-55% open vats are used in the present collection system. The operational efficiency of the Kolkata Municipal Corporation (KMC) transport system is about 50%, with a fleet composed of about 30-35% old vehicles. The majority (80%) of these, particularly the hired vehicles, are more than 20 years old. The newly added areas covered by KMC have even lower collection efficiencies, and only an informal recycling system exists. The waste collected has a low energy value (3,350-4,200 kJ kg{sup -1}) with high moisture and inert content. A 700 t d{sup -1} compost plant set up in 2000 has not been functioning effectively since 2003. Open dumping (without liners and without a leachate management facility) and the threat of groundwater pollution, as well as saturation of an existing landfill site (Dhapa) are the most pressing problems for the city today. KMC spends 70-75% of its total expenditures on collection of solid waste, 25-30% on transportation, and less than 5% on final disposal arrangements. The Kolkata Environmental Improvement Project, funded by the Asian Development Bank, is seen as only a partial solution to the problem. A detailed plan should emphasize segregation at the source, investment in disposal arrangements (including the use of liners and leachate collection), and an optimized transport arrangement, among improvements.

Chattopadhyay, Subhasish [Solid Waste Management Department, KMC, Department of Civil Engineering, Bengal Engineering and Science University, Shibpur, Howrah 711103 (India)], E-mail: subharpita@rediffmail.com; Dutta, Amit [Department of Civil Engineering, Bengal Engineering and Science University, P.O. Botanic Garden, Shibpur, Howrah 711 103 (India)], E-mail: amit@civil.becs.ac.in; Ray, Subhabrata [Department of Chemical Engineering, Indian Institute of Technology, Kharagpur 721302 (India)], E-mail: sray@che.iitkhp.ernet.in

2009-04-15T23:59:59.000Z

54

LCA comparison of container systems in municipal solid waste management  

Science Conference Proceedings (OSTI)

The planning and design of integrated municipal solid waste management (MSWM) systems requires accurate environmental impact evaluation of the systems and their components. This research assessed, quantified and compared the environmental impact of the first stage of the most used MSW container systems. The comparison was based on factors such as the volume of the containers, from small bins of 60-80 l to containers of 2400 l, and on the manufactured materials, steel and high-density polyethylene (HDPE). Also, some parameters such as frequency of collections, waste generation, filling percentage and waste container contents, were established to obtain comparable systems. The methodological framework of the analysis was the life cycle assessment (LCA), and the impact assessment method was based on CML 2 baseline 2000. Results indicated that, for the same volume, the collection systems that use HDPE waste containers had more of an impact than those using steel waste containers, in terms of abiotic depletion, global warming, ozone layer depletion, acidification, eutrophication, photochemical oxidation, human toxicity and terrestrial ecotoxicity. Besides, the collection systems using small HDPE bins (60 l or 80 l) had most impact while systems using big steel containers (2400 l) had less impact. Subsequent sensitivity analysis about the parameters established demonstrated that they could change the ultimate environmental impact of each waste container collection system, but that the comparative relationship between systems was similar.

Rives, Jesus, E-mail: Jesus.Rives@uab.ca [SosteniPrA (UAB-IRTA), Institute of Environmental Science and Technology (ICTA), Universitat Autonoma de Barcelona - UAB, 08193 Bellaterra, Barcelona (Spain); Rieradevall, Joan; Gabarrell, Xavier [SosteniPrA (UAB-IRTA), Institute of Environmental Science and Technology (ICTA), Universitat Autonoma de Barcelona - UAB, 08193 Bellaterra, Barcelona (Spain); Department of Chemical Engineering, Universitat Autonoma de Barcelona - UAB, 08193 Bellaterra, Barcelona (Spain)

2010-06-15T23:59:59.000Z

55

Energy potential of municipal solid waste is limited  

SciTech Connect

Energy recovery from municipal solid waste has the potential for making only a limited contribution to the nation`s overall energy production. Although the current contribution of waste-derived energy production is less than one-half of 1 percent of the nation`s total energy Supply, DOE has set a goal for energy from waste at 2 percent of the total supply by 2010. The industry`s estimates show a smaller role for waste as an energy source in the future. The energy potential from waste is limited not only by the volume and energy content of the waste itself, but also by the factors affecting the use of waste disposal options, including public opposition and the availability of financing. Energy production from waste combustors and from landfill gases generates pollutants, although these are reduced through current regulations that require the use of emissions control technology and define operational criteria for the facilities. Although DOE estimates that one-third of the energy available from waste is available in the form of energy savings through the recycling of materials, the Department`s research in this area is ongoing.

NONE

1994-09-01T23:59:59.000Z

56

Use of ash from municipal solid waste combustion. Final report  

DOE Green Energy (OSTI)

This report details the results of efforts to integrate municipal solid waste combustion ash into a high strength portland cement concrete matrix comprised of multiple waste materials. The material developed by this research was to be used to construct a large underground storage vault to house the Friendly Mobile Barrier, a safety barrier system for use at highway crossings for the high speed rail system. The subcontractor, Environmental Solutions, Inc., of Richmond, Virginia, worked with researchers at Pennsylvania State University and the State University of New York--Stony Brook to develop and test the material. The result of this work is a portland cement concrete matrix which utilizes 80.01% recycled materials, and a field-applicable method for incorporating MSW ash as a component at volumes up to 9.78%. Twenty-eight day strengths of over 4000 psi were achieved, with 315 day strengths of 6500 psi. All structural, chemical and environmental testing showed the material to be competitive with conventional concrete.

NONE

1997-07-01T23:59:59.000Z

57

Hydrogen production by gasification of municipal solid waste  

DOE Green Energy (OSTI)

As fossil fuel reserves run lower and lower, and as their continued widespread use leads toward numerous environmental problems, the need for clean and sustainable energy alternatives becomes ever clearer. Hydrogen fuel holds promise as such as energy source, as it burns cleanly and can be extracted from a number of renewable materials such as municipal solid waste (MSW), which can be considered largely renewable because of its high content of paper and biomass-derived products. A computer model is being developed using ASPEN Plus flow sheeting software to simulate a process which produces hydrogen gas from MSW; the model will later be used in studying the economics of this process and is based on an actual Texaco coal gasification plant design. This paper gives an overview of the complete MSW gasification process, and describes in detail the way in which MSW is modeled by the computer as a process material. In addition, details of the gasifier unit model are described; in this unit modified MSW reacts under pressure with oxygen and steam to form a mixture of gases which include hydrogen.

Rogers, R. III

1994-05-20T23:59:59.000Z

58

Micro-scale anaerobic digestion of point source components of organic fraction of municipal solid waste  

E-Print Network (OSTI)

Micro-scale anaerobic digestion of point source components of organic fraction of municipal solid that are needed when designing plug-flow type anaerobic bioreactors. More specifically, the decomposition patterns

Columbia University

59

Evaluation of gasification and novel thermal processes for the treatment of municipal solid waste  

DOE Green Energy (OSTI)

This report identifies seven developers whose gasification technologies can be used to treat the organic constituents of municipal solid waste: Energy Products of Idaho; TPS Termiska Processor AB; Proler International Corporation; Thermoselect Inc.; Battelle; Pedco Incorporated; and ThermoChem, Incorporated. Their processes recover heat directly, produce a fuel product, or produce a feedstock for chemical processes. The technologies are on the brink of commercial availability. This report evaluates, for each technology, several kinds of issues. Technical considerations were material balance, energy balance, plant thermal efficiency, and effect of feedstock contaminants. Environmental considerations were the regulatory context, and such things as composition, mass rate, and treatability of pollutants. Business issues were related to likelihood of commercialization. Finally, cost and economic issues such as capital and operating costs, and the refuse-derived fuel preparation and energy conversion costs, were considered. The final section of the report reviews and summarizes the information gathered during the study.

Niessen, W.R.; Marks, C.H.; Sommerlad, R.E. [Camp Dresser and McKee, Inc., Cambridge, MA (United States)] [Camp Dresser and McKee, Inc., Cambridge, MA (United States)

1996-08-01T23:59:59.000Z

60

Heating and cooling of municipal buildings with waste heat from ground water  

DOE Green Energy (OSTI)

The feasibility of using waste heat from municipal water wells to replace natural gas for heating of the City Hall, Fire Station, and Community Hall in Wilmer, Texas was studied. At present, the 120/sup 0/F well water is cooled by dissipating the excess heat through evaporative cooling towers before entering the distribution system. The objective of the study was to determine the pumping cycle of the well and determine the amount of available heat from the water for a specified period. This data were correlated with the heating and cooling demand of the City's buildings, and a conceptual heat recovery system will be prepared. The system will use part or all of the excess heat from the water to heat the buildings, thereby eliminating the use of natural gas. The proposed geothermal retrofit of the existing natural gas heating system is not economical because the savings in natural gas does not offset the capital cost of the new equipment and the annual operating and maintenance costs. The fuel savings and power costs are a virtual trade-off over the 25-year period. The installation and operation of the system was estimated to cost $105,000 for 25 years which is an unamortized expense. In conclusion, retrofitting the City of Wilmer's municipal buildings is not feasible based on the economic analysis and fiscal projections as presented.

Morgan, D.S.; Hochgraf, J.

1980-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Development of a Segregated Municipal Solid Waste Gasification System for Electrical Power Generation  

E-Print Network (OSTI)

Gasification technologies are expected to play a key role in the future of solid waste management since the conversion of municipal and industrial solid wastes to a gaseous fuel significantly increases its value. Municipal solid waste (MSW) gasification for electrical power generation was conducted in a fluidized bed gasifier and the feasibility of using a control system was evaluated to facilitate its management and operation. The performance of an engine using the gas produced was evaluated. A procedure was also tested to upgrade the quality of the gas and optimize its production. The devices installed and automated control system developed was able to achieve and maintain the set conditions for optimum gasification. The most important parameters of reaction temperature and equivalence ratio were fully controlled. Gas production went at a rate of 4.00 kg min-1 with a yield of 2.78 m3 kg-1 of fuel and a heating value (HV) of 7.94 MJ Nm-3. Within the set limits of the tests, the highest production of synthesis gas and the net heating value of 8.97 MJ Nm-3 resulted from gasification at 725°C and ER of 0.25 which was very close to the predicted value of 7.47 MJ Nm-3. This was not affected by temperature but significantly affected by the equivalence ratio. The overall engine-generator efficiency at 7.5 kW electrical power load was lower at 19.81% for gasoline fueled engine compared to 35.27% for synthesis gas. The pressure swing adsorption (PSA) system increased the net heating value of the product gas by an average of 38% gas over that of inlet gas. There were no traces of carbon dioxide in the product gas indicating that it had been completely adsorbed by the system. MSW showed relatively lower fouling and slagging tendencies than cotton gin trash (CGT) and dairy manure (DM). This was further supported by the compressive strength measurements of the ash of MSW, CGT and DM and the EDS elemental analysis of the MSW ash.

Maglinao, Amado Latayan

2013-05-01T23:59:59.000Z

62

MidAmerican Energy (Electric) - Municipal Solid-State Lighting Grant  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

MidAmerican Energy (Electric) - Municipal Solid-State Lighting MidAmerican Energy (Electric) - Municipal Solid-State Lighting Grant Program MidAmerican Energy (Electric) - Municipal Solid-State Lighting Grant Program < Back Eligibility Local Government Savings Category Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Minimum project size for the full $5,000 grant is 20 fixtures; smaller projects will receive a $250 per-fixture grant. Program Info State Iowa Program Type Utility Grant Program Rebate Amount Up to $5,000 Provider MidAmerican Energy Company MidAmerican Energy offers grants to munipalities which implement solid-state roadway street lighting upgrades. Grants of up to $5,000 are available to participating entities who install eligible roadway lighting fixtures. Participants must be an Iowa electric governmental customer of

63

Solid state radiative heat pump  

DOE Patents (OSTI)

A solid state radiative heat pump (10, 50, 70) operable at room temperature (300.degree. K.) utilizes a semiconductor having a gap energy in the range of 0.03-0.25 eV and operated reversibly to produce an excess or deficit of charge carriers as compared to thermal equilibrium. In one form of the invention (10, 70) an infrared semiconductor photodiode (21, 71) is used, with forward or reverse bias, to emit an excess or deficit of infrared radiation. In another form of the invention (50), a homogeneous semiconductor (51) is subjected to orthogonal magnetic and electric fields to emit an excess or deficit of infrared radiation. Three methods of enhancing transmission of radiation through the active surface of the semiconductor are disclosed. In one method, an anti-reflection layer (19) is coated into the active surface (13) of the semiconductor (11), the anti-reflection layer (19) having an index of refraction equal to the square root of that of the semiconductor (11). In the second method, a passive layer (75) is spaced from the active surface (73) of the semiconductor (71) by a submicron vacuum gap, the passive layer having an index of refractive equal to that of the semiconductor. In the third method, a coupler (91) with a paraboloid reflecting surface (92) is in contact with the active surface (13, 53) of the semiconductor (11, 51), the coupler having an index of refraction about the same as that of the semiconductor.

Berdahl, Paul H. (Oakland, CA)

1986-01-01T23:59:59.000Z

64

Solid state radiative heat pump  

DOE Patents (OSTI)

A solid state radiative heat pump operable at room temperature (300 K) utilizes a semiconductor having a gap energy in the range of 0.03-0.25 eV and operated reversibly to produce an excess or deficit of change carriers as compared equilibrium. In one form of the invention an infrared semiconductor photodiode is used, with forward or reverse bias, to emit an excess or deficit of infrared radiation. In another form of the invention, a homogenous semiconductor is subjected to orthogonal magnetic and electric fields to emit an excess or deficit of infrared radiation. Three methods of enhancing transmission of radiation the active surface of the semiconductor are disclosed. In one method, an anti-refection layer is coated into the active surface of the semiconductor, the anti-reflection layer having an index of refraction equal to the square root of that of the semiconductor. In the second method, a passive layer is speaced trom the active surface of the semiconductor by a submicron vacuum gap, the passive layer having an index of refractive equal to that of the semiconductor. In the third method, a coupler with a paraboloid reflecting surface surface is in contact with the active surface of the semiconductor, the coupler having an index of refraction about the same as that of the semiconductor.

Berdahl, P.H.

1984-09-28T23:59:59.000Z

65

Data summary of municipal solid waste management alternatives  

Science Conference Proceedings (OSTI)

This appendix contains the alphabetically indexed bibliography for the complete group of reports on municipal waste management alternatives. The references are listed for each of the following topics: mass burn technologies, RDF technologies, fluidized-bed combustion, pyrolysis and gasification of MSW, materials recovery- recycling technologies, sanitary landfills, composting, and anaerobic digestion of MSW.

Not Available

1992-10-01T23:59:59.000Z

66

MidAmerican Energy (Electric) - Municipal Solid-State Lighting Grant  

Open Energy Info (EERE)

MidAmerican Energy (Electric) - Municipal Solid-State Lighting Grant MidAmerican Energy (Electric) - Municipal Solid-State Lighting Grant Program (Iowa) No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Summary Last modified on November 9, 2012. Financial Incentive Program Place Iowa Additional Place applies to MidAmerican Energy Name MidAmerican Energy (Electric) - Municipal Solid-State Lighting Grant Program Incentive Type Utility Grant Program Applicable Sector Local Government Eligible Technologies Lighting, Lighting Controls/Sensors, Induction Lighitng, LED Lighting Active Incentive Yes Implementing Sector Utility Energy Category Energy Efficiency Incentive Programs Amount Up to $5,000 Equipment Requirements Fixtures must have an efficiency rating equal to or greater than 66 lumens per watt as tested under Illuminating Engineering Society of North America LM-79-08 testing to qualify for a grant.

67

Biogas generation by two-phase anaerobic digestion of organic fraction of municipal solid waste  

Science Conference Proceedings (OSTI)

The organic fraction of municipal solid waste can be a significant energy source for renewable energy generation. The total production of municipal solid waste in Turkey was 25?×?106 tones per year. Anaerobic digestion (AD) process may be a solution to the problems of energy demand and waste management since it provides biomethanation along with waste stabilization. AD can be operated in single or two phase configurations. Two-phase processes have some advantages over one phase systems in terms of selection of microorganisms

Eylem Dogan; Göksel N. Demirer

2012-01-01T23:59:59.000Z

68

Municipal District Heating and Cooling Co-generation System Feasibility Research  

E-Print Network (OSTI)

In summer absorption refrigerating machines provide cold water using excess heat from municipal thermoelectric power plant through district heating pipelines, which reduces peak electric load from electricity networks in summer. The paper simulates annual dynamic load of a real project to calculate the first investments, annual operation cost and LCC (life cycle cost) of the four schemes, which are electric chillers, electric chillers with ice-storage system, absorption refrigerating machines using excess heat from power plant and absorption refrigerating machines using excess heat from power plant along with ice-storage system. On the basis of the results, the paper analyzes the prospect of the absorption refrigeration using municipal excess heat, as well as the reasonable heat price, which provides a theoretical basis for municipal heating and cooling co-generation development.

Zhang, W.; Guan, W.; Pan, Y.; Ding, G.; Song, X.; Zhang, Y.; Li, Y.; Wei, H.; He, Y.

2006-01-01T23:59:59.000Z

69

Syn-Gas Production from Catalytic Steam Gasification of Municipal Solid Wastes in a Combined Fixed Bed Reactor  

Science Conference Proceedings (OSTI)

The catalytic steam gasi?cation of municipal solid wastes (MSW) for syn-gas production was experimentally investigated in a combined fixed bed reactor using the newly developed tri-metallic catalyst. A series of experiments have been performed to explore ... Keywords: Biomass gasification, municipal solid wastes, catalyst, hydrogen production, energy recovery

Jianfen Li; Jianjun Liu; Shiyan Liao; Xiaorong Zhou; Rong Yan

2010-10-01T23:59:59.000Z

70

High temperature behavior of electrostatic precipitator ash from municipal solid waste combustors  

E-Print Network (OSTI)

combustion may cause the oxidation of mercury, and chloride mercury #12;13 13 species may be the major form combustion and gasification flue gases, Environ. Sci. Technol. 30 (1996) 2421-2426. [23] S.B. Ghorishi, C Ms. Ref. No.: HAZMAT-D-07-00176 Accepted manuscript #12;2 2 Abstract Municipal solid waste (MSW) flue

Paris-Sud XI, Université de

71

DISTRICT ENERGY SYSTEMS POWERED THROUGH THE COMBUSTION OF MUNICIPAL SOLID WASTE  

E-Print Network (OSTI)

.assure.org Biography: Mr. Tomberlin has 21 years of experience in the design of power generation facilities having & Brad Moorman Barlow Projects, Inc. 2000 Vermont Drive, Fort Collins, CO 80525 (970) 226-8557 info municipal solid waste (MSW) by 90%-95% creating energy in the form of steam and/or electricity

Columbia University

72

THE BURNING ISSUES OF MUNICIPAL SOLID WASTE DISPOSAL WHAT WORKS AND WHAT DOESN'T  

E-Print Network (OSTI)

1 THE BURNING ISSUES OF MUNICIPAL SOLID WASTE DISPOSAL ­ WHAT WORKS AND WHAT DOESN'T By: Jack D devil burns and the Lord recycles." Perhaps these negative references to waste burning come from, the Valley of Hinnom south of ancient Jerusalem. This was the site of a foul, smoking, open burning garbage

Columbia University

73

MidAmerican Energy (Electric) - Municipal Solid-State Lighting...  

Open Energy Info (EERE)

must be an Iowa electric governmental customer of MidAmerican Energy Company. Light-emitting diode and induction types of solid state lighting (SSL) qualify under this program....

74

Municipal solid waste combustion: Fuel testing and characterization  

DOE Green Energy (OSTI)

The objective of this study is to screen and characterize potential biomass fuels from waste streams. This will be accomplished by determining the types of pollutants produced while burning selected municipal waste, i.e., commercial mixed waste paper residential (curbside) mixed waste paper, and refuse derived fuel. These materials will be fired alone and in combination with wood, equal parts by weight. The data from these experiments could be utilized to size pollution control equipment required to meet emission standards. This document provides detailed descriptions of the testing methods and evaluation procedures used in the combustion testing and characterization project. The fuel samples will be examined thoroughly from the raw form to the exhaust emissions produced during the combustion test of a densified sample.

Bushnell, D.J.; Canova, J.H.; Dadkhah-Nikoo, A.

1990-10-01T23:59:59.000Z

75

Heat Recovery From Solid Waste  

E-Print Network (OSTI)

More opportunity exists today for the successful implementation of resource recovery projects than at any other period. However, that doesn't mean that energy/resource recovery exists for everyone. You must have a favorable match of all the critical areas of evaluation, including the cost of fuel, cost of solid waste disposal, plant energy requirements, available technology, etc.

Underwood, O. W.

1981-01-01T23:59:59.000Z

76

Combustion of municipal solid wastes with oil shale in a circulating fluidized bed. Final report  

DOE Green Energy (OSTI)

The problem addressed by our invention is that of municipal solid waste utilization. The dimensions of the problem can be visualized by the common comparison that the average individual in America creates in five years time an amount of solid waste equivalent in weight to the Statue of Liberty. The combustible portion of the more than 11 billion tons of solid waste (including municipal solid waste) produced in the United States each year, if converted into useful energy, could provide 32 quads per year of badly needed domestic energy, or more than one-third of our annual energy consumption. Conversion efficiency and many other factors make such a production level unrealistic, but it is clear that we are dealing with a very significant potential resource. This report describes research pertaining to the co-combustion of oil shale with solid municipal wastes in a circulating fluidized bed. The oil shale adds significant fuel content and also constituents that can possible produce a useful cementitious ash.

NONE

1996-06-30T23:59:59.000Z

77

Constructed wetlands for municipal solid waste landfill leachate treatment. Final report  

SciTech Connect

In 1989, the US Geological Survey and Cornell University, in cooperation with the New York State Energy Research and Development Authority and the Tompkins County Solid Waste Department, began a three-year study at a municipal solid-waste landfill near Ithaca, New York, to test the effectiveness of leachate treatment with constructed wetlands and to examine the associated treatment processes. Specific objectives of the study were to examine: treatment efficiency as function of substrate composition and grain size, degree of plant growth, and seasonal changes in evapotranspiration rates and microbial activity; effects of leachate and plant growth on the hydraulic characteristics of the substrate; and chemical, biological, and physical processes by which nutrients, metals, and organic compounds are removed from leachate as it flows through the substrate. A parallel study at a municipal solid-waste landfill near Fenton, New York was conducted by researchers at Cornell University, Ithaca College, and Hawk Engineering (Trautmann and others, 1989). Results are described.

Peverly, J.; Sanford, W.E.; Steenhuis, T.S. [Cornell Univ., Ithaca, NY (United States)

1993-11-01T23:59:59.000Z

78

A study of tritium in municipal solid waste leachate and gas  

Science Conference Proceedings (OSTI)

It has become increasingly clear in the last few years that the vast majority of municipal solid waste landfills produce leachate that contains elevated levels of tritium. The authors recently conducted a study of landfills in New York and New Jersey and found that the mean concentration of tritium in the leachate from ten municipal solid waste (MSW) landfills was 33,800 pCi/L with a peak value of 192,000 pCi/L. A 2003 study in California reported a mean tritium concentration of 99,000 pCi/L with a peak value of 304,000 pCi/L. Studies in Pennsylvania and the UK produced similar results. The USEPA MCL for tritium is 20,000 pCi/L. Tritium is also manifesting itself as landfill gas and landfill gas condensate. Landfill gas condensate samples from landfills in the UK and California were found to have tritium concentrations as high as 54,400 and 513,000 pCi/L, respectively. The tritium found in MSW leachate is believed to derive principally from gaseous tritium lighting devices used in some emergency exit signs, compasses, watches, and even novelty items, such as 'glow stick' key chains. This study reports the findings of recent surveys of leachate from a number of municipal solid waste landfills, both open and closed, from throughout the United States and Europe. The study evaluates the human health and ecological risks posed by elevated tritium levels in municipal solid waste leachate and landfill gas and the implications to their safe management. We also assess the potential risks posed to solid waste management facility workers exposed to tritium-containing waste materials in transfer stations and other solid waste management facilities. (authors)

Mutch Jr, R. D. [HydroQual, Inc., 1200 MacArthur Blvd., Mahwah, NJ 07430 (United States); Manhattan College, Riverdale, NY (United States); Columbia Univ., New York, NY (United States); Mahony, J. D. [HydroQual, Inc., 1200 MacArthur Blvd., Mahwah, NJ 07430 (United States); Manhattan College, Riverdale, NY (United States)

2008-07-15T23:59:59.000Z

79

Atmospheric fluidized bed combustion of municipal solid waste: test program results  

DOE Green Energy (OSTI)

Air classified municipal solid waste (MSW) was fired in an atmospheric fluidized bed combustor at low excess air to simulate boiler conditions. The 7 ft/sup 2/ combustor at Combustion Power Company's energy laboratory in Menlo Park, CA, incorporates water tubes for heat extraction and recycles elutriated particles to the bed. System operation was stable while firing processed MSW for the duration of a 300-h test. Low excess air, low exhaust gas emissions, and constant bed temperature demonstrated feasibility of steam generation from fluidized bed combustion of MSW. During the 300-h test, combustion efficiency averaged 99%. Excess air was typically 44% while an average bed temperature of 1400/sup 0/F and an average superficial gas velocity of 4.6 fps were maintained. Typical exhaust emission levels were 30 ppM SO/sub 2/, 160 ppM NO/sub x/, 200 ppM CO, and 25 ppM hydrocarbons. No agglomeration of bed material or detrimental change in fluidization properties was experienced. A conceptual design study of a full scale plant to be located at Stanford University was based on process conditions from the 300-h test. The plant would produce 250,000 lb/hr steam at the maximum firing rate of 1000 tons per day (TPD) processed MSW. The average 800 TPD firing rate would utilize approximately 1200 TPD raw MSW from surrounding communities. The Stanford Solid Waste energy Program was aimed at development of a MSW-fired fluidized bed boiler and cogeneration plant to supply most of the energy needs of Stanford University.

Preuit, L C; Wilson, K B

1980-05-01T23:59:59.000Z

80

Municipal solid waste management: A bibliography of US Department of Energy contractor report through 1994  

Science Conference Proceedings (OSTI)

U.S. Department of Energy contractors continue to conduct research targeting the productive and responsible use of the more than 516,000 metric tons (567,000 tons) of municipal solid waste (MSW) that is generated each day in the United States. It is becoming more and more prudent to improve current methods of MSW management and to continue to search for additional cost-effective, energy-efficient means to manage our MSW resource. This bibliography provides information about technical reports on energy from municipal waste that were prepared under grants or contracts from the US DOE. The reports listed focus on energy from municipal waste technologies and energy conservation in wastewater treatment.

NONE

1995-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

A study of the metal content of municipal solid waste. Final report  

DOE Green Energy (OSTI)

Knowledge of the content of toxic components, so called pollutant precursors, in the municipal solid waste (MSW) stream is essential to development of the strategies for source reduction and reuse, recycling, composting and disposal. Data are scarce; trends in composition for any locality even more so. In a previous study the total and water soluble chlorine content of the components of municipal solid waste were determined from sampling studies at two sites, Baltimore County, MD, and Brooklyn, NY, each for a five day period. The total sulfur content of the combined combustible components was also determined. Because of the scarcity of data and synergistic effects, it seemed appropriate to determine the heavy metal content of the preceding material prior to its disposal. The metals chosen were the so-called priority pollutant metals (PPM): antimony, arsenic, beryllium, cadmium, chromium, copper, lead, mercury, nickel, selenium, silver, thallium, and zinc.

Churney, K.L.; Domalski, E.S.

1998-01-01T23:59:59.000Z

82

Prototype demonstration of dual sorbent injection for acid gas control on municipal solid waste combustion units  

SciTech Connect

This report gathered and evaluated emissions and operations data associated with furnace injection of dry hydrated lime and duct injection of dry sodium bicarbonate at a commercial, 1500 ton per day, waste-to-energy facility. The information compiled during the project sheds light on these sorbents to affect acid gas emissions from municipal solid waste combustors. The information assesses the capability of these systems to meet the 1990 Clean Air Act and 1991 EPA Emission Guidelines.

None

1994-05-01T23:59:59.000Z

83

Municipal Solid Waste (MSW) to Liquid Fuels Synthesis, Volume 1: Availability of Feedstock and Technology  

DOE Green Energy (OSTI)

This report investigated the potential of using municipal solid waste (MSW) to make synthesis gas (syngas) suitable for production of liquid fuels. Issues examined include: • MSW physical and chemical properties affecting its suitability as a gasifier feedstock and for liquid fuels synthesis • expected process scale required for favorable economics • the availability of MSW in quantities sufficient to meet process scale requirements • the state-of-the-art of MSW gasification technology.

Valkenburg, Corinne; Walton, Christie W.; Thompson, Becky L.; Gerber, Mark A.; Jones, Susanne B.; Stevens, Don J.

2008-12-01T23:59:59.000Z

84

Municipal water-based heat pump heating and/or cooling systems: Findings and recommendations. Final report  

SciTech Connect

The purpose of the present work was to determine if existing heat pump systems based on municipal water systems meet existing water quality standards, to analyze water that has passed through a heat pump or heat exchanger to determine if corrosion products can be detected, to determine residual chlorine levels in municipal waters on the inlet as well as the outlet side of such installations, to analyses for bacterial contaminants and/or regrowth due to the presence of a heat pump or heat exchanger, to develop and suggest criteria for system design and construction, to provide recommendations and specifications for material and fluid selection, and to develop model rules and regulations for the installation, operation, and monitoring of new and existing systems. In addition, the Washington State University (WSU) has evaluated availability of computer models that would allow for water system mapping, water quality modeling and system operation.

Bloomquist, R.G. [Washington, State Univ., Pullman, WA (United States); Wegman, S. [South Dakota Utilities Commission (United States)

1998-04-01T23:59:59.000Z

85

Municipal solid waste management: A bibliography of US Department of Energy contractor reports through 1993  

Science Conference Proceedings (OSTI)

US Department of Energy contractors continue to conduct research targeting the productive and responsible use of the more than 536,000 tons of municipal solid waste (MSW) that is generated each day in the United States. It is becoming more and more prudent to improve current methods of MSW management and to continue to search for additional cost-effective, energy-efficient means to manage our MSW resource. This bibliography is an updated version of Municipal Waste to Energy: An Annotated Bibliography of US Department of Energy Contractor Reports, by Caroline Brooks, published in 1987. Like its predecessor, this bibliography provides information about technical reports on energy from municipal waste that were prepared under grants or contracts from the US Department of Energy. The reports listed focus on energy from municipal waste technologies and energy conservation in wastewater treatment. The bibliography contains three indexes -- an author index, a subject index, and a title index. The reports are listed alphabetically in the subject areas and may appear under more than one subject. All of the reports cited in the original MSW bibliography are also included in this update. The number of copies of each report originally published varied according to anticipated public demand. However, all reports are available in either microfiche or hard copy form and may be ordered from the National Technical Information Service (NTIS), US Department of Commerce, Springfield, VA 22161. Explicit information on ordering reports is included in Appendix A.

Shepherd, P.

1994-07-01T23:59:59.000Z

86

Effects of residues from municipal solid waste landfill on corn yield and heavy metal content  

Science Conference Proceedings (OSTI)

The effects of residues from municipal solid waste landfill, Khon Kaen Municipality, Thailand, on corn (Zea mays L.) yield and heavy metal content were studied. Field experiments with randomized complete block design with five treatments (0, 20, 40, 60 and 80% v/v of residues and soil) and four replications were carried out. Corn yield and heavy metal contents in corn grain were analyzed. Corn yield increased by 50, 72, 85 and 71% at 20, 40, 60 and 80% treatments as compared to the control, respectively. All heavy metals content, except cadmium, nickel and zinc, in corn grain were not significantly different from the control. Arsenic, cadmium and zinc in corn grain were strongly positively correlated with concentrations in soil. The heavy metal content in corn grain was within regulated limits for human consumption.

Prabpai, S. [Suphan Buri Campus Establishment Project, Kasetsart University, 50 U Floor, Administrative Building, Paholyothin Road, Jatujak, Bangkok 10900 (Thailand)], E-mail: s.prabpai@hotmail.com; Charerntanyarak, L. [Department of Epidemiology, Faculty of Public Health, Khon Kaen University, Khon Kaen 40002 (Thailand)], E-mail: lertchai@kku.ac.th; Siri, B. [Department of Agronomy, Faculty of Agriculture, Khon Kaen University, Khon Kaen 40002 (Thailand)], E-mail: boonmee@kku.ac.th; Moore, M.R. [The University of Queensland, The National Research Center for Environmental Toxicology, 39 Kessels Road, Coopers Plans, Brisbane, Queensland 4108 (Australia)], E-mail: m.moore@uq.edu.au; Noller, Barry N. [The University of Queensland, Centre for Mined Land Rehabilitation, Brisbane, Queensland 4072 (Australia)], E-mail: b.noller@uq.edu.au

2009-08-15T23:59:59.000Z

87

Life-cycle assessment of municipal solid wastes: Development of the WASTED model  

Science Conference Proceedings (OSTI)

This paper describes the development of the Waste Analysis Software Tool for Environmental Decisions (WASTED) model. This model provides a comprehensive view of the environmental impacts of municipal solid waste management systems. The model consists of a number of separate submodels that describe a typical waste management process: waste collection, material recovery, composting, energy recovery from waste and landfilling. These submodels are combined to represent a complete waste management system. WASTED uses compensatory systems to account for the avoided environmental impacts derived from energy recovery and material recycling. The model is designed to provide solid waste decision-makers and environmental researchers with a tool to evaluate waste management plans and to improve the environmental performance of solid waste management strategies. The model is user-friendly and compares favourably with other earlier models.

Diaz, R. [Civil Engineering Department, Ryerson University, 350 Victoria Street, Toronto, Ont., M5B 2K3 (Canada); Warith, M. [Civil Engineering Department, Ryerson University, 350 Victoria Street, Toronto, Ont., M5B 2K3 (Canada)]. E-mail: mwarith@ryerson.ca

2006-07-01T23:59:59.000Z

88

Municipal geothermal heat utilization plan for Glenwood Springs, Colorado  

DOE Green Energy (OSTI)

A study has been made of the engineering and economic feasibility of utilizing the geothermal resource underlying Glenwood Springs Colorado, to heat a group of public buildings. The results have shown that the use of geothermal heat is indeed feasible when compared to the cost of natural gas. The proposed system is composed of a wellhead plate heat exchanger which feeds a closed distribution loop of treated water circulated to the buildings which form the load. The base case system was designed to supply twice the demand created by the seven public buildings in order to take advantage of some economies of scale. To increase the utilization factor of the available geothermal energy, a peaking boiler which burns natural gas is recommended. Disposal of the cooled brine would be via underground injection. Considerable study was done to examine the impact of reduced operating temperature on the existing heating systems. Several options to minimize this problem were identified. Economic analyses were completed to determine the present values of heat from the geothermal system and from the present natural gas over a 30 year projected system life. For the base case savings of over $1 million were shown. Sensitivities of the economics to capital cost, operating cost, system size and other parameters were calculated. For all reasonable assumptions, the geothermal system was cheaper. Financing alternatives were also examined. An extensive survey of all existing data on the geology of the study has led to the prediction of resource parameters. The wellhead temperature of produced fluid is suspected to lie between 140 and 180/sup 0/F (60 and 82/sup 0/C). Flowrates may be as high as 1000 gpm (3800 liters per minute) from a reservoir formation that is 300 ft (90 m) thick beginning about 500 ft (150 m) below the suggested drill site in the proposed Two Rivers Park.

Not Available

1980-12-31T23:59:59.000Z

89

Assessment of municipal solid waste for energy production in the western United States  

Science Conference Proceedings (OSTI)

Municipal solid waste (MSW) represents both a significant problem and an abundant resource for the production of energy. The residential, institutional, and industrial sectors of this country generate about 250 million tons of MSW each year. In this report, the authors have compiled data on the status of MSW in the 13-state western region, including economic and environmental issues. The report is designed to assist the members of the Western Regional Biomass Energy Program Ad Hoc Resource Committee in determining the potential for using MSW to produce energy in the region. 51 refs., 7 figs., 18 tabs.

Goodman, B.J.; Texeira, R.H.

1990-08-01T23:59:59.000Z

90

National survey of industrial markets for steam produced from burning municipal solid waste  

DOE Green Energy (OSTI)

This report presents the methodology and findings of an analysis to determine the maximum size of the industrial market for steam produced from municipal solid waste in the United States. The data used in the analysis were developed from the 1980 census report and the US Chamber of Commerce's 1979 Standard Industrial Classification (SIC) listing. The process used to match potential steam users with populations large enough to generate suitable quantities of waste is presented. No attempt was made to rank the markets or analyze the market economics.

Pearson, C.V.

1983-09-01T23:59:59.000Z

91

Evaluation of Energy Recovery from Municipal Solid Waste in Oil-Fired Power Plants  

Science Conference Proceedings (OSTI)

Five methods of energy recovery from municipal solid waste (MSW) in oil-fired power plants are evaluated: preparation and supplemental firing of refuse-derived fuel (RDF) with oil in a utility boiler originally designed for coal firing; 100% firing of either RDF or MSW in a dedicated water-wall incinerator and use of the steam to drive a dedicated turbine generator unit; and 100% firing of RDF or MSW in a dedicated water-wall incinerator and integration of the steam into the power plant steam cycle.

1982-02-01T23:59:59.000Z

92

Energy recovery from municipal solid waste, an environmental and safety mini-overview survey  

DOE Green Energy (OSTI)

The environmental and safety aspects of processing municipal solid wastes to recover energy and materials are reviewed in some detail. The state of the art in energy recovery, energy potential for the near and long-term, and constraints to commercialization are discussed. Under the environmental and safety aspects the state of the art, need for research and development, and need for coordination among federal agencies and private industry are considered. Eleven principal types of refuse-to-energy processes are described and a projected energy balance is derived for each process. (JSR)

Johnson, R.L.

1976-06-01T23:59:59.000Z

93

Solid0Core Heat-Pipe Nuclear Batterly Type Reactor  

DOE Green Energy (OSTI)

This project was devoted to a preliminary assessment of the feasibility of designing an Encapsulated Nuclear Heat Source (ENHS) reactor to have a solid core from which heat is removed by liquid-metal heat pipes (HP).

Ehud Greenspan

2008-09-30T23:59:59.000Z

94

Methanogenic Population Dynamics during Start-Up of Anaerobic Digesters Treating Municipal Solid Waste  

E-Print Network (OSTI)

Abstract: An aggressive start-up strategy was used to initiate codigestion in two anaerobic, continuously mixed bench-top reactors at mesophilic (37°C) and thermophilic (55°C) conditions. The digesters were inoculated with mesophilic anaerobic sewage sludge and cattle manure and were fed a mixture of simulated municipal solid waste and biosolids in proportions that reflect U.S. production rates. The design organic loading rate was 3.1 kg volatile solids/m 3 /day and the retention time was 20 days. Ribosomal RNA-targeted oligonucleotide probes were used to determine the methanogenic community structure in the inocula and the digesters. Chemical analyses were performed to evaluate digester performance. The aggressive start-up strategy was successful for the thermophilic reactor, despite the use of a

Biosolids; Matt E. Griffin; Katherine D. Mcmahon; Roderick I. Mackie; Lutgarde Raskin

1997-01-01T23:59:59.000Z

95

Municipal solid waste management challenges in developing countries - Kenyan case study  

Science Conference Proceedings (OSTI)

This paper provides an overview of the state of municipal solid waste management (MSWM) by local authorities in Kenya as a case study of a low-income developing country. Approaches of possible solutions that can be undertaken to improve municipal solid waste (MSW) services are discussed. Poor economic growth (1.1% in 1993) has resulted in an increase in the poverty level which presently stands at 56%. Migration from the rural areas to the urban areas has resulted in unplanned settlements in suburban areas accommodating about 60% of the urban population on only 5% urban land area. Political interference also hampers smooth running of local authorities. Vulnerability of pollution of surface and groundwater is high because local authorities rarely considered environmental impact in siting MSW disposal sites. Illegal dumping of MSW on the river banks or on the roadside poses environmental and economic threats on nearby properties. Poor servicing of MSW collection vehicles, poor state of infrastructure and the lack of adequate funding militate against optimization of MSW disposal service. The rural economy needs to be improved if rural-urban migration is to be managed. Involvement of stakeholders is important to achieve any meaningful and sustainable MSWM. The role of the informal sector through community-based organizations (CBOs), Non-Governmental Organizations (NGOs) and the private sector in offering solutions towards improvement of MSWM also is explored.

Henry, Rotich K. [College of Environment and Resources, Jilin University, Changchun 130026 (China); Zhao Yongsheng [College of Environment and Resources, Jilin University, Changchun 130026 (China)]. E-mail: zhaoyongsheng@jlu.edu.cn; Dong Jun [College of Environment and Resources, Jilin University, Changchun 130026 (China)

2006-07-01T23:59:59.000Z

96

Municipal solid waste source-separated collection in China: A comparative analysis  

Science Conference Proceedings (OSTI)

A pilot program focusing on municipal solid waste (MSW) source-separated collection was launched in eight major cities throughout China in 2000. Detailed investigations were carried out and a comprehensive system was constructed to evaluate the effects of the eight-year implementation in those cities. This paper provides an overview of different methods of collection, transportation, and treatment of MSW in the eight cities; as well as making a comparative analysis of MSW source-separated collection in China. Information about the quantity and composition of MSW shows that the characteristics of MSW are similar, which are low calorific value, high moisture content and high proportion of organisms. Differences which exist among the eight cities in municipal solid waste management (MSWM) are presented in this paper. Only Beijing and Shanghai demonstrated a relatively effective result in the implementation of MSW source-separated collection. While the six remaining cities result in poor performance. Considering the current status of MSWM, source-separated collection should be a key priority. Thus, a wider range of cities should participate in this program instead of merely the eight pilot cities. It is evident that an integrated MSWM system is urgently needed. Kitchen waste and recyclables are encouraged to be separated at the source. Stakeholders involved play an important role in MSWM, thus their responsibilities should be clearly identified. Improvement in legislation, coordination mechanisms and public education are problematic issues that need to be addressed.

Tai Jun [Shanghai Key Laboratory of Urbanization and Ecological Restoration, East China Normal University, Shanghai 200062 (China); Shanghai Environmental Engineering Design Research Institute, Shanghai 200232 (China); Zhang Weiqian [Shanghai Key Laboratory of Urbanization and Ecological Restoration, East China Normal University, Shanghai 200062 (China); Che Yue, E-mail: yche@des.ecnu.edu.cn [Shanghai Key Laboratory of Urbanization and Ecological Restoration, East China Normal University, Shanghai 200062 (China); Feng Di [Shanghai Environmental Engineering Design Research Institute, Shanghai 200232 (China)

2011-08-15T23:59:59.000Z

97

Recovery and recycling practices in municipal solid waste management in Lagos, Nigeria  

Science Conference Proceedings (OSTI)

The population of Lagos, the largest city in Nigeria, increased seven times from 1950 to 1980 with a current population of over 10 million inhabitants. The majority of the city's residents are poor. The residents make a heavy demand on resources and, at the same time, generate large quantities of solid waste. Approximately 4 million tonnes of municipal solid waste (MSW) is generated annually in the city, including approximately 0.5 million of untreated industrial waste. This is approximately 1.1 kg/cap/day. Efforts by the various waste management agencies set up by the state government to keep its streets and neighborhoods clean have achieved only minimal success. This is because more than half of these wastes are left uncollected from the streets and the various locations due to the inadequacy and inefficiency of the waste management system. Whilst the benefits of proper solid waste management (SWM), such as increased revenues for municipal bodies, higher productivity rate, improved sanitation standards and better health conditions, cannot be overemphasized, it is important that there is a reduction in the quantity of recoverable materials in residential and commercial waste streams to minimize the problem of MSW disposal. This paper examines the status of recovery and recycling in current waste management practice in Lagos, Nigeria. Existing recovery and recycling patterns, recovery and recycling technologies, approaches to materials recycling, and the types of materials recovered from MSW are reviewed. Based on these, strategies for improving recovery and recycling practices in the management of MSW in Lagos, Nigeria are suggested.

Kofoworola, O.F. [Environment Division, Joint Graduate School of Energy and Environment, King Mongkuts University of Technology Thonburi, 91 Prachauthit Road, Bangmod, Tungkru, Bangkok 10140 (Thailand)], E-mail: sholafemi28@yahoo.com

2007-07-01T23:59:59.000Z

98

Data summary of municipal solid waste management alternatives. Volume 1, Report text  

Science Conference Proceedings (OSTI)

This report provides data for use in evaluating the proven technologies and combinations of technologies that might be considered for managing municipal solid waste (MSW). It covers five major methods for MSW management in common use today: Landfilling; Mass combustion for energy recovery; Production of refuse-derived fuel (RDF); Collection/separation of recyclables; and Composting. It also provides information on three MSW management technologies that are not widely used at present: Anaerobic digestion; Cofiring of MSW with coal; and Gasification/pyrolysis. To the extent possible with available reliable data, the report presents information for each proven MSW technology on: Net energy balances; Environmental releases; and Economics. In addition to data about individual operations, the report presents net energy balances and inventories of environmental releases from selected combined MSW management strategies that use two or more separate operations. The scope of the report extends from the waste`s origin (defined as the point at which the waste is set out for collection), through transportation and processing operations, to its final disposition (e.g., recycling and remanufacturing, combustion, or landfilling operations). Data for all operations are presented on a consistent basis: one (1) ton of municipal (i.e., residential, commercial, and institutional) waste at the collection point. Selection of an MSW management plan may be influenced by many factors, in addition to the technical performance and economics of each option.

Not Available

1992-10-01T23:59:59.000Z

99

On-line early fault detection and diagnosis of municipal solid waste incinerators  

Science Conference Proceedings (OSTI)

A fault detection and diagnosis framework is proposed in this paper for early fault detection and diagnosis (FDD) of municipal solid waste incinerators (MSWIs) in order to improve the safety and continuity of production. In this framework, principal component analysis (PCA), one of the multivariate statistical technologies, is used for detecting abnormal events, while rule-based reasoning performs the fault diagnosis and consequence prediction, and also generates recommendations for fault mitigation once an abnormal event is detected. A software package, SWIFT, is developed based on the proposed framework, and has been applied in an actual industrial MSWI. The application shows that automated real-time abnormal situation management (ASM) of the MSWI can be achieved by using SWIFT, resulting in an industrially acceptable low rate of wrong diagnosis, which has resulted in improved process continuity and environmental performance of the MSWI.

Zhao Jinsong [College of Information Science and Technology, Beijing University of Chemical Technology, Beijing 100029 (China)], E-mail: jinsongzhao@mail.tsinghua.edu.cn; Huang Jianchao [College of Information Science and Technology, Beijing Institute of Technology, Beijing 10086 (China); Sun Wei [College of Chemical Engineering, Beijing University of Chemical Technology, Beijing 100029 (China)

2008-11-15T23:59:59.000Z

100

An analytic network process model for municipal solid waste disposal options  

SciTech Connect

The aim of this paper is to present an evaluation method that can aid decision makers in a local civic body to prioritize and select appropriate municipal solid waste disposal methods. We introduce a hierarchical network (hiernet) decision structure and apply the analytic network process (ANP) super-matrix approach to measure the relative desirability of disposal alternatives using value judgments as the input of the various stakeholders. ANP is a flexible analytical program that enables decision makers to find the best possible solution to complex problems by breaking down a problem into a systematic network of inter-relationships among the various levels and attributes. This method therefore may not only aid in selecting the best alternative but also helps decision makers to understand why an alternative is preferred over the other options.

Khan, Sheeba [Department of Civil and Environmental Engineering, Youngstown State University, OH 44555, United States of America (United States)], E-mail: sheebanishat@yahoo.com; Faisal, Mohd Nishat [Department of Management Studies, Indian Institute of Technology Delhi, New Delhi 110 016 (India)], E-mail: nishat786@yahoo.com

2008-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Anaerobic digestion of pressed off leachate from the organic fraction of municipal solid waste  

Science Conference Proceedings (OSTI)

A highly polluted liquid ('press water') was obtained from the pressing facility for the organic fraction of municipal solid waste in a composting plant. Methane productivity of the squeezed-off leachate was investigated in batch assays. To assess the technical feasibility of 'press water' as a substrate for anaerobic digestion, a laboratory-scale glass column reactor was operated semi-continuously at 37 {sup o}C. A high methane productivity of 270 m{sup -3} CH{sub 4} ton{sup -1} COD{sub added} or 490 m{sup -3} CH{sub 4} ton{sup -1} VS{sub added} was achieved in the batch experiment. The semi-continuously run laboratory-scale reactor was initially operated at an organic loading rate of 10.7 kg COD m{sup -3} d{sup -1}. The loading was increased to finally 27.7 kg COD m{sup -3} d{sup -1}, corresponding to a reduction of the hydraulic retention time from initially 20 to finally 7.7 days. During the digestion, a stable elimination of organic material (measured as COD elimination) of approximately 60% was achieved. Linearly with the increment of the OLR, the volumetric methane production of the reactor increased from 2.6 m{sup 3} m{sub reactor}{sup -3} d{sup -1} to 7.1 m{sup 3} m{sub reactor}{sup -3} d{sup -1}. The results indicated that 'press water' from the organic fraction of municipal solid waste was a suitable substrate for anaerobic digestion which gave a high biogas yield even at very high loading rates.

Nayono, Satoto E. [Department of Civil Engineering, Yogyakarta State University, Campus UNY Karangmalang Yogyakarta 55281 (Indonesia); Institute of Biology for Engineers and Biotechnology of Wastewater, University of Karlsruhe, Am Fasanengarten, 76131 Karlsruhe (Germany); Winter, Josef, E-mail: josef.winter@iba.uka.d [Institute of Biology for Engineers and Biotechnology of Wastewater, University of Karlsruhe, Am Fasanengarten, 76131 Karlsruhe (Germany); Gallert, Claudia [Institute of Biology for Engineers and Biotechnology of Wastewater, University of Karlsruhe, Am Fasanengarten, 76131 Karlsruhe (Germany)

2010-10-15T23:59:59.000Z

102

Review of composting and anaerobic digestion of municipal solid waste and a methodological proposal for a mid-size city  

E-Print Network (OSTI)

Review of composting and anaerobic digestion of municipal solid waste and a methodological proposal and processes on composting and anaerobic digestion are compiled, showing the versatility and multivariable of the compost. In addition, anaerobic decomposition followed by vermicomposting is pointed as one of the best

Wisconsin-Milwaukee, University of

103

Simulation model of heat distribution and consumption in municipal heating network  

Science Conference Proceedings (OSTI)

This paper describes the designed and implemented computer model of the distribution system of heat consumption in the urban agglomeration (SHDC - System of Heat Distribution and Consumption). This model is designed as a simulation model. The simulation ... Keywords: discrete simulation, heat consumption, heat distribution, modeling

L. Vašek; V. Dolinay

2010-07-01T23:59:59.000Z

104

Processing high solids concentration of municipal solid waste by anaerobic digester for methane production  

SciTech Connect

Cellulosic solids are pretreated by calcium hydroxide to produce salts of volatile orangic acids and other water-soluble substances. Pure cellulose, sawdust, and waste paper are used as model substances for the study of alkaline degradation. It is found that sawdust is more difficult to degrade than the other two substances. The cooking conditions for high conversion of model substances and high yeild of orangic acids are found to be 275/degree/C to 300/degree/C with the corresponding reaction time from 30 minutes to 15 minutes. The cooking liquor can be readily fermented in an anaerobic fluidized-bed digester for methane production. The cooking liquor from different reaction conditions can all be digested by the methanogens. Higher than 90% of COD can be removed under the conditions of low organic loading rate (<2.0 g COD/1/day) and low hydraulic retention time (1.5 to 2.0 days). 14 refs., 10 figs., 2 tabs.

Tsao, G.T.

1988-01-01T23:59:59.000Z

105

Fuzzy multicriteria disposal method and site selection for municipal solid waste  

Science Conference Proceedings (OSTI)

The use of fuzzy multiple criteria analysis (MCA) in solid waste management has the advantage of rendering subjective and implicit decision making more objective and analytical, with its ability to accommodate both quantitative and qualitative data. In this paper a modified fuzzy TOPSIS methodology is proposed for the selection of appropriate disposal method and site for municipal solid waste (MSW). Our method is superior to existing methods since it has capability of representing vague qualitative data and presenting all possible results with different degrees of membership. In the first stage of the proposed methodology, a set of criteria of cost, reliability, feasibility, pollution and emission levels, waste and energy recovery is optimized to determine the best MSW disposal method. Landfilling, composting, conventional incineration, and refuse-derived fuel (RDF) combustion are the alternatives considered. The weights of the selection criteria are determined by fuzzy pairwise comparison matrices of Analytic Hierarchy Process (AHP). It is found that RDF combustion is the best disposal method alternative for Istanbul. In the second stage, the same methodology is used to determine the optimum RDF combustion plant location using adjacent land use, climate, road access and cost as the criteria. The results of this study illustrate the importance of the weights on the various factors in deciding the optimized location, with the best site located in Catalca. A sensitivity analysis is also conducted to monitor how sensitive our model is to changes in the various criteria weights.

Ekmekcioglu, Mehmet, E-mail: meceng3584@yahoo.co [Istanbul Technical University, Department of Management Engineering, 34367 Macka, Istanbul (Turkey); Kaya, Tolga [Istanbul Technical University, Department of Management Engineering, 34367 Macka, Istanbul (Turkey); Kahraman, Cengiz [Istanbul Technical University, Department of Industrial Engineering, 34367 Macka, Istanbul (Turkey)

2010-08-15T23:59:59.000Z

106

The impact of municipal solid waste treatment methods on greenhouse gas emissions in Lahore, Pakistan  

Science Conference Proceedings (OSTI)

The contribution of existing municipal solid waste management to emission of greenhouse gases and the alternative scenarios to reduce emissions were analyzed for Data Ganj Bukhsh Town (DGBT) in Lahore, Pakistan using the life cycle assessment methodology. DGBT has a population of 1,624,169 people living in 232,024 dwellings. Total waste generated is 500,000 tons per year with an average per capita rate of 0.84 kg per day. Alternative scenarios were developed and evaluated according to the environmental, economic, and social atmosphere of the study area. Solid waste management options considered include the collection and transportation of waste, collection of recyclables with single and mixed material bank container systems (SMBCS, MMBCS), material recovery facilities (MRF), composting, biogasification and landfilling. A life cycle inventory (LCI) of the six scenarios along with the baseline scenario was completed; this helped to quantify the CO{sub 2} equivalents, emitted and avoided, for energy consumption, production, fuel consumption, and methane (CH{sub 4}) emissions. LCI results showed that the contribution of the baseline scenario to the global warming potential as CO{sub 2} equivalents was a maximum of 838,116 tons. The sixth scenario had a maximum reduction of GHG emissions in terms of CO{sub 2} equivalents of -33,773 tons, but the most workable scenario for the current situation in the study area is scenario 5. It saves 25% in CO{sub 2} equivalents compared to the baseline scenario.

Batool, Syeda Adila [Department of Space Science, Punjab University, Lahore 54600 (Pakistan)], E-mail: aadila_batool@yahoo.com; Chuadhry, Muhammad Nawaz [College of Earth and Environmental Sciences, University of the Punjab, Lahore (Pakistan)], E-mail: muhammadnawazchaudhry@yahoo.com

2009-01-15T23:59:59.000Z

107

Micro-scale anaerobic digestion of point source components of organic fraction of municipal solid waste  

Science Conference Proceedings (OSTI)

The fermentation characteristics of six specific types of the organic fraction of municipal solid waste (OFMSW) were examined, with an emphasis on properties that are needed when designing plug-flow type anaerobic bioreactors. More specifically, the decomposition patterns of a vegetable (cabbage), fruits (banana and citrus peels), fresh leaf litter of bamboo and teak leaves, and paper (newsprint) waste streams as feedstocks were studied. Individual OFMSW components were placed into nylon mesh bags and subjected to various fermentation periods (solids retention time, SRT) within the inlet of a functioning plug-flow biogas fermentor. These were removed at periodic intervals, and their composition was analyzed to monitor decomposition rates and changes in chemical composition. Components like cabbage waste, banana peels, and orange peels fermented rapidly both in a plug-flow biogas reactor (PFBR) as well as under a biological methane potential (BMP) assay, while other OFMSW components (leaf litter from bamboo and teak leaves and newsprint) fermented slowly with poor process stability and moderate biodegradation. For fruit and vegetable wastes (FVW), a rapid and efficient removal of pectins is the main cause of rapid disintegration of these feedstocks, which left behind very little compost forming residues (2-5%). Teak and bamboo leaves and newsprint decomposed only to 25-50% in 30 d. These results confirm the potential for volatile fatty acids accumulation in a PFBR's inlet and suggest a modification of the inlet zone or operation of a PFBR with the above feedstocks.

Chanakya, H.N. [Centre for Sustainable Technologies, (formerly ASTRA), Indian Institute of Science, Bangalore 560 012 (India)], E-mail: chanakya@astra.iisc.ernet.in; Sharma, Isha [Centre for Sustainable Technologies, (formerly ASTRA), Indian Institute of Science, Bangalore 560 012 (India); Ramachandra, T.V. [Centre for Sustainable Technologies, (formerly ASTRA), Indian Institute of Science, Bangalore 560 012 (India); Centre for Ecological Sciences, Indian Institute of Science, Bangalore 560 012 (India)

2009-04-15T23:59:59.000Z

108

An environmental assessment of recovering methane from municipal solid waste by anaerobic digestion  

Science Conference Proceedings (OSTI)

The development of an experimental process which produces synthetic natural gas (SNG) or biogas by anaerobic digestion of municipal solid waste (MSW) is evaluated. This technology, if implemented, would be utilized in lieu of incineration or directly landfilling waste. An environmental assessment describing the principal impacts associated with operating the MSW anaerobic digestion process is presented. Variations in process configurations provide for SNG or electricity production and digester residue incineration, composting, or landfilling. Four process configuration are compared to the conventional solid waste disposal alternative of mass burn incineration and landfilling. Emissions are characterized, effluents quantified, and landfill areas predicted. The quantity of SNG and electricity recovered, and aluminum and ferrous metals recycled is predicted along with the emissions and effluents avoided by recovering energy and recycling metals. Air emissions are the primary on-site concern with the anaerobic digestion process. However, when compared to mass burn incineration, the projected particulate emissions for the anaerobic digestion process range from 2.9 {times} 10{sup {minus}6} to 2.6 {times} {sup 10{minus}5} pounds per ton of waste vs. 3.3 {times} 10{sup {minus}5} pounds per ton for mass burn. SO{sub 2}, NO{sub x}, and PCCD emissions have a similar relationship.

O'Leary, P.R.

1989-01-01T23:59:59.000Z

109

Leachability of heavy metals from growth media containing source-separated municipal solid waste compost  

Science Conference Proceedings (OSTI)

The leaching of heavy metals in source-separated municipal solid waste (MSW) compost was determined by irrigation leaching of growth medium, admixed with varying amounts of compost, used for container grown plants. Perennial flowers (black-eyed Susan, Rudbeckia hirta L.) were grown in 2-L containers filled with the growth medium for a 10-wk period. Rainfall was supplemented with overhead irrigation to supply 2 cm of water per day. Leachates collected over each 2-wk period were analyzed for Cd, Cr, Cu, Ni, Pb, and Zn using atomic spectrometry. Concentrations of the heavy metals in the leachates increased with increasing proportions of MSW compost in the growth medium, but decreased with time of leaching. Leaching of the metals occurred at relatively high concentrations initially, followed by continued leaching at low concentrations. The initial leaching of heavy metals is attributed to their soluble or exchangeable forms and the subsequent slow leaching to the solid compounds. The concentrations of the heavy metals remained below the current drinking water standards in all treatments throughout the leaching period. The results thus suggest that contamination of groundwater with heavy metals from source-separated MSW compost applied as a soil amendment should be negligible, as the low concentrations in the leachates leaving the surface soil would be further attenuated by the subsoil. 29 refs., 6 figs., 1 tab.

Sawhney, B.L.; Bugbee, G.J.; Stilwell, D.E. [Connecticut Agricultural Experimental Station, New Haven, CT (United States)

1994-07-01T23:59:59.000Z

110

Municipal solid waste incineration bottom ash: Characterization and kinetic studies of organic matter  

SciTech Connect

Bottom ash is the main solid residue which is produced by municipal solid waste incineration (MSWI) facilities. To be reused in public works, it has to be stored previously a few months. This material is composed primarily of a mineral matrix but also contains unburnt organic matter. The mineral content and its change in the course of aging are relatively well-known, in contrast with the organic content. So in order to detect the phenomena responsible for changes in organic matter and their effects during aging, the concentrations of the main organic compounds previously characterized, the number of microorganisms, and the release of carbon dioxide were followed kinetically in model laboratory conditions. The results showed that the aging process led to the natural biodegradation of the organic matter available in bottom ash, composed essentially of carboxylic acids and n-alkanes (steroids and PAH`s to a lesser extent), and consequently that it would improve the bottom ash quality. Furthermore these results were confirmed by the study of aging conducted in conditions used in the industrial scale.

Dugenest, S.; Casabianca, H.; Grenier-Loustalot, M.F. [Centre National de la Recherche Scientifique, Vernaison (France). Service central d`Analyse; Combrisson, J. [Univ. Claude Bernard-Lyon I, Villeurbanne (France). Lab. d`Ecologie Microbienne du Sol

1999-04-01T23:59:59.000Z

111

Municipal solid waste management in Africa: Strategies and livelihoods in Yaounde, Cameroon  

Science Conference Proceedings (OSTI)

This paper provides an overview of the state of municipal solid waste (MSW) management in the capital of Cameroon, Yaounde, and suggests some possible solutions for its improvement. The institutional, financial, and physical aspects of MSW management, as well as the livelihoods of the population, were analyzed. Our study revealed that distances and lack of infrastructure have a major impact on waste collection. Garbage bins are systematically mentioned as the primary infrastructure needed by the population in all quarters, whether it be a high or low standard community. The construction of transfer stations and the installation of garbage bins are suggested as a solution to reduce distances between households and garbage bins, thus improving waste collection vehicle accessibility. Transfer stations and garbage bins would enable the official waste collection company to expand its range of services and significantly improve waste collection rates. Several transfer stations have already been set up by non-governmental organizations (NGOs) and community-based organizations (CBOs), but they require technical, institutional and funding support. Research is needed on the quality and safety of community-made compost, as well as on soil fertility in urban and peri-urban areas. Most of the stakeholders, municipalities, the official waste collection company and households acknowledge the need for better monitoring and regulation of MSW management. The urban community of Yaounde also needs to maintain its support of MSW management and promote the sustainability of NGOs and CBOs operating in underserved areas not yet covered by adequate infrastructures. A major opportunity for implementation of such waste policy is the heavily indebted poor countries (HIPC) program dedicated to urban planning and good governance.

Parrot, Laurent [Centre de Cooperation Internationale en Recherche Agronomique pour le Developpement (CIRAD), Montpellier 34398 Cedex 5 (France)], E-mail: laurent.parrot@cirad.fr; Sotamenou, Joel; Dia, Bernadette Kamgnia [University of Yaounde II - Soa, Faculty of Economics and Management, P.O. Box 1365, Yaounde (Cameroon)

2009-02-15T23:59:59.000Z

112

Municipal solid waste management in India: From waste disposal to recovery of resources?  

SciTech Connect

Unlike that of western countries, the solid waste of Asian cities is often comprised of 70-80% organic matter, dirt and dust. Composting is considered to be the best option to deal with the waste generated. Composting helps reduce the waste transported to and disposed of in landfills. During the course of the research, the author learned that several developing countries established large-scale composting plants that eventually failed for various reasons. The main flaw that led to the unsuccessful establishment of the plants was the lack of application of simple scientific methods to select the material to be composted. Landfills have also been widely unsuccessful in countries like India because the landfill sites have a very limited time frame of usage. The population of the developing countries is another factor that detrimentally impacts the function of landfill sites. As the population keeps increasing, the garbage quantity also increases, which, in turn, exhausts the landfill sites. Landfills are also becoming increasingly expensive because of the rising costs of construction and operation. Incineration, which can greatly reduce the amount of incoming municipal solid waste, is the second most common method for disposal in developed countries. However, incinerator ash may contain hazardous materials including heavy metals and organic compounds such as dioxins, etc. Recycling plays a large role in solid waste management, especially in cities in developing countries. None of the three methods mentioned here are free from problems. The aim of this study is thus to compare the three methods, keeping in mind the costs that would be incurred by the respective governments, and identify the most economical and best option possible to combat the waste disposal problem.

Narayana, Tapan [Hidayatullah National Law University, HNLU Bhawan, Civil Lines, Raipur 492001, Chhattisgarh (India)], E-mail: tapan.narayana@gmail.com

2009-03-15T23:59:59.000Z

113

Peak Demand Reduction with Dual-Source Heat Pumps Using Municipal Water  

E-Print Network (OSTI)

The objective of this project was to examine a dual-source (air and/or water-coupled) heat pump concept which would reduce or eliminate the need for supplemental electrical resistance heating (strip heaters). The project examined two system options: switching on demand between completely air-source and completely water-coupled or using a concurrent partial water-coupled and partial air-coupled mode operation. The water supply for the water-coupled mode of operation would be the municipal water system. An estimate of the economic worth of this system concept was made by examining the incremental cost to install such a system against the expected savings associated with these systems.

Morehouse, J. H.; Khan, J. A.; Connor, L. N.; Pal, D.

1992-05-01T23:59:59.000Z

114

Co-gasification of municipal solid waste and material recovery in a large-scale gasification and melting system  

Science Conference Proceedings (OSTI)

Highlights: Black-Right-Pointing-Pointer This study evaluates the effects of co-gasification of MSW with MSW bottom ash. Black-Right-Pointing-Pointer No significant difference between MSW treatment with and without MSW bottom ash. Black-Right-Pointing-Pointer PCDD/DFs yields are significantly low because of the high carbon conversion ratio. Black-Right-Pointing-Pointer Slag quality is significantly stable and slag contains few hazardous heavy metals. Black-Right-Pointing-Pointer The final landfill amount is reduced and materials are recovered by DMS process. - Abstract: This study evaluates the effects of co-gasification of municipal solid waste with and without the municipal solid waste bottom ash using two large-scale commercial operation plants. From the viewpoint of operation data, there is no significant difference between municipal solid waste treatment with and without the bottom ash. The carbon conversion ratios are as high as 91.7% and 95.3%, respectively and this leads to significantly low PCDD/DFs yields via complete syngas combustion. The gross power generation efficiencies are 18.9% with the bottom ash and 23.0% without municipal solid waste bottom ash, respectively. The effects of the equivalence ratio are also evaluated. With the equivalence ratio increasing, carbon monoxide concentration is decreased, and carbon dioxide and the syngas temperature (top gas temperature) are increased. The carbon conversion ratio is also increased. These tendencies are seen in both modes. Co-gasification using the gasification and melting system (Direct Melting System) has a possibility to recover materials effectively. More than 90% of chlorine is distributed in fly ash. Low-boiling-point heavy metals, such as lead and zinc, are distributed in fly ash at rates of 95.2% and 92.0%, respectively. Most of high-boiling-point heavy metals, such as iron and copper, are distributed in metal. It is also clarified that slag is stable and contains few harmful heavy metals such as lead. Compared with the conventional waste management framework, 85% of the final landfill amount reduction is achieved by co-gasification of municipal solid waste with bottom ash and incombustible residues. These results indicate that the combined production of slag with co-gasification of municipal solid waste with the bottom ash constitutes an ideal approach to environmental conservation and resource recycling.

Tanigaki, Nobuhiro, E-mail: tanigaki.nobuhiro@nsc-eng.co.jp [Nippon Steel Engineering Co., Ltd. (Head Office), Osaki Center Building 1-5-1, Osaki, Shinagawa-ku, Tokyo 141-8604 (Japan); Manako, Kazutaka [Nippon Steel Engineering Co., Ltd., 46-59, Nakabaru, Tobata-ku, Kitakyushu, Fukuoka 804-8505 (Japan); Osada, Morihiro [Nippon Steel Engineering Co., Ltd. (Head Office), Osaki Center Building 1-5-1, Osaki, Shinagawa-ku, Tokyo 141-8604 (Japan)

2012-04-15T23:59:59.000Z

115

Guide to implementing reclamation processes at Department of Defense municipal solid waste and construction debris landfills. Master's thesis  

Science Conference Proceedings (OSTI)

This thesis serves as a guide for implementing landfill reclamation techniques on municipal solid waste or construction debris landfills owned, operated, or used by the DoD. The research describes historical and current methods for disposing of solid waste including open dumping, sanitary landfilling, and the development of state-of-the-art sanitary landfill cell technology. The thesis also identifies the factors which have led to the need for new methods of managing municipal solid waste. The vast majority of the study is devoted to identifying actions which should be taken before, during, and after implementation of a landfill reclamation project. These actions include the development of health, safety, and contingency planning documents, the establishment of systems for characterizing and monitoring site conditions, and the identification of other procedures and processes necessary for performing successful operations. Finally, this study contains a model for analyzing under which conditions reclamation is economically feasible. The model examines economic feasibility in four separate conditions and shows that reclamation is economically feasible in a wide variety of markets. However, the model also shows that feasibility is directly associated with a continuance of normal landfilling operations. Landfill, Landfill reclamation, Landfill mining, Municipal solid waste, Recycling, Construction debris.

Tures, G.L.

1993-09-21T23:59:59.000Z

116

Dry-thermophilic anaerobic digestion of organic fraction of municipal solid waste: Methane production modeling  

SciTech Connect

Highlights: Black-Right-Pointing-Pointer Methane generation may be modeled by means of modified product generation model of Romero Garcia (1991). Black-Right-Pointing-Pointer Organic matter content and particle size influence the kinetic parameters. Black-Right-Pointing-Pointer Higher organic matter content and lower particle size enhance the biomethanization. - Abstract: The influence of particle size and organic matter content of organic fraction of municipal solid waste (OFMSW) in the overall kinetics of dry (30% total solids) thermophilic (55 Degree-Sign C) anaerobic digestion have been studied in a semi-continuous stirred tank reactor (SSTR). Two types of wastes were used: synthetic OFMSW (average particle size of 1 mm; 0.71 g Volatile Solids/g waste), and OFMSW coming from a composting full scale plant (average particle size of 30 mm; 0.16 g Volatile Solids/g waste). A modification of a widely-validated product-generation kinetic model has been proposed. Results obtained from the modified-model parameterization at steady-state (that include new kinetic parameters as K, Y{sub pMAX} and {theta}{sub MIN}) indicate that the features of the feedstock strongly influence the kinetics of the process. The overall specific growth rate of microorganisms ({mu}{sub max}) with synthetic OFMSW is 43% higher compared to OFMSW coming from a composting full scale plant: 0.238 d{sup -1} (K = 1.391 d{sup -1}; Y{sub pMAX} = 1.167 L CH{sub 4}/gDOC{sub c}; {theta}{sub MIN} = 7.924 days) vs. 0.135 d{sup -1} (K = 1.282 d{sup -1}; Y{sub pMAX} = 1.150 L CH{sub 4}/gDOC{sub c}; {theta}{sub MIN} = 9.997 days) respectively. Finally, it could be emphasized that the validation of proposed modified-model has been performed successfully by means of the simulation of non-steady state data for the different SRTs tested with each waste.

Fdez-Gueelfo, L.A., E-mail: alberto.fdezguelfo@uca.es [Department of Chemical Engineering and Food Technology, Faculty of Science, University of Cadiz, 11510 Puerto Real, Cadiz (Spain); Alvarez-Gallego, C. [Department of Chemical Engineering and Food Technology, Faculty of Science, University of Cadiz, 11510 Puerto Real, Cadiz (Spain); Sales, D. [Department of Environmental Technologies, Faculty of Marine and Environmental Sciences, University of Cadiz, 11510 Puerto Real, Cadiz (Spain); Romero Garcia, L.I. [Department of Chemical Engineering and Food Technology, Faculty of Science, University of Cadiz, 11510 Puerto Real, Cadiz (Spain)

2012-03-15T23:59:59.000Z

117

Integrated municipal solid waste treatment using a grate furnace incinerator: The Indaver case  

SciTech Connect

An integrated installation for treatment of municipal solid waste and comparable waste from industrial origin is described. It consists of three grate furnace lines with flue gas treatment by half-wet scrubbing followed by wet scrubbing, and an installation for wet treatment of bottom ash. It is demonstrated that this integrated installation combines high recovery of energy (40.8% net) with high materials recovery. The following fractions were obtained after wet treatment of the bottom ash: ferrous metals, non-ferrous metals, three granulate fractions with different particle sizes, and sludge. The ferrous and non-ferrous metal fractions can both be recycled as high quality raw materials; the two larger particle size particle fractions can be applied as secondary raw materials in building applications; the sand fraction can be used for applications on a landfill; and the sludge is landfilled. For all components of interest, emissions to air are below the limit values. The integrated grate furnace installation is characterised by zero wastewater discharge and high occupational safety. Moreover, with the considered installation, major pollutants, such as PCDD/PCDF, Hg and iodine-136 are to a large extent removed from the environment and concentrated in a small residual waste stream (flue gas cleaning residue), which can be landfilled after stabilisation.

Vandecasteele, C. [Department of Chemical Engineering, Katholieke Universiteit Leuven, De Croylaan 46, 3001 Leuven (Belgium)], E-mail: carlo.vandecasteele@cit.kuleuven.be; Wauters, G. [Indaver, Dijle 17a, 2800 Mechelen (Belgium); Arickx, S. [Department of Chemical Engineering, Katholieke Universiteit Leuven, De Croylaan 46, 3001 Leuven (Belgium); Jaspers, M. [Indaver, Dijle 17a, 2800 Mechelen (Belgium); Van Gerven, T. [Department of Chemical Engineering, Katholieke Universiteit Leuven, De Croylaan 46, 3001 Leuven (Belgium)

2007-07-01T23:59:59.000Z

118

A comparison of municipal solid waste management in Berlin and Singapore  

SciTech Connect

A comparative analysis of municipal solid waste management (MSWM) in Singapore and Berlin was carried out in order to identify its current status, and highlight the prevailing conditions of MSWM. An overview of the various aspects of MSWM in these two cities is provided, with emphasis on comparing the legal, technical, and managerial aspects of MSW. Collection systems and recycling practiced with respect to the involvement of the government and the private sector, are also presented. Over last two decades, the city of Berlin has made impressive progress with respect to its waste management. The amounts of waste have declined significantly, and at the same time the proportion that could be recovered and recycled has increased. In contrast, although Singapore's recycling rate has been increasing over the past few years, rapid economic and population growth as well as change in consumption patterns in this city-state has caused waste generation to continue to increase. Landfilling of MSW plays minor role in both cities, one due to geography (Singapore) and the other due to legislative prohibition (Berlin). Consequently, both in Singapore and Berlin, waste is increasingly being used as a valuable resource and great efforts have been made for the development of incineration technology and energy recovery, as well as climate protection.

Zhang Dongqing, E-mail: dqzhang@ntu.edu.s [DHI-NTU Centre, Nanyang Environment and Water Research Institute, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Keat, Tan Soon [Maritime Research Centre, School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore); Gersberg, Richard M. [Graduate School of Public Health, San Diego State University, Hardy Tower 119, 5500 Campanile, San Diego CA 92182-4162 (United States)

2010-05-15T23:59:59.000Z

119

Life cycle assessment of four municipal solid waste management scenarios in China  

Science Conference Proceedings (OSTI)

A life cycle assessment was carried out to estimate the environmental impact of municipal solid waste. Four scenarios mostly used in China were compared to assess the influence of various technologies on environment: (1) landfill, (2) incineration, (3) composting plus landfill, and (4) composting plus incineration. In all scenarios, the technologies significantly contribute to global warming and increase the adverse impact of non-carcinogens on the environment. The technologies played only a small role in the impact of carcinogens, respiratory inorganics, terrestrial ecotoxicity, and non-renewable energy. Similarly, the influence of the technologies on the way other elements affect the environment was ignorable. Specifically, the direct emissions from the operation processes involved played an important role in most scenarios except for incineration, while potential impact generated from transport, infrastructure and energy consumption were quite small. In addition, in the global warming category, highest potential impact was observed in landfill because of the direct methane gas emissions. Electricity recovery from methane gas was the key factor for reducing the potential impact of global warming. Therefore, increasing the use of methane gas to recover electricity is highly recommended to reduce the adverse impact of landfills on the environment.

Hong Jinglan, E-mail: hongjing@sdu.edu.c [School of Environmental Science and Engineering, Shandong University, Jinan 250100 (China); Li Xiangzhi [Department of Pathology, University of Michigan, 1301 Catherine, Ann Arbor, MI 48109 (United States); Zhaojie Cui [School of Environmental Science and Engineering, Shandong University, Jinan 250100 (China)

2010-11-15T23:59:59.000Z

120

Oxygen respirometry to assess stability and maturity of composted municipal solid waste  

Science Conference Proceedings (OSTI)

The stability and maturity of compost prepared from municipal solid waste (MSW) at a full-scale composting plant was assessed through chemical, physical, and biological assays. Respiration bioassays used to determine stability (O{sub 2} and CO{sub 2} respirometry) were sensitive to process control problems at the composting plant and indicated increasing stability with time. Radish (Raphanus sativus L.) and ryegrass (Lolium perenne L.) growth bioassays revealed that immature compost samples inhibited growth. Growth of ryegrass in potting mix prepared with cured compost not amended with fertilizer was enhanced as compared to a pest control. Garden cress (Lepidium sativum L.) seed germination, used as an indicator of phytotoxicity, revealed inhibition of germination at all compost maturity levels. The phytotoxicity was though to be salt-related. Spearman rank-order correlations demonstrated that O{sub 2} respirometry, water-soluble organic C, and the water extract organic C to organic N ratio, significantly correlated with compost age and best indicated an acceptable level of stability. Oxygen respirometry also best predicted the potential for ryegrass growth, and an acceptable level of compost maturity. 31 refs., 4 figs., 5 tabs.

Iannotti, D.A.; Grebus, M.E.; Toth, B.L.; Madden, L.V.; Hoitink, A.J. [Ohio State Univ./Ohio Agricultural Research and Development Center, Wooster, OH (United States)

1994-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Flow analysis of metals in a municipal solid waste management system  

Science Conference Proceedings (OSTI)

This study aimed to identify the metal flow in a municipal solid waste (MSW) management system. Outputs of a resource recovery facility, refuse derived fuel (RDF) production facility, carbonization facility, plastics liquefaction facility, composting facility, and bio-gasification facility were analyzed for metal content and leaching concentration. In terms of metal content, bulky and incombustible waste had the highest values. Char from a carbonization facility, which treats household waste, had a higher metal content than MSW incinerator bottom ash. A leaching test revealed that Cd and Pb in char and Pb in RDF production residue exceeded the Japanese regulatory criteria for landfilling, so special attention should be paid to final disposal of these substances. By multiplying metal content and the generation rate of outputs, the metal content of input waste to each facility was estimated. For most metals except Cr, the total contribution ratio of paper/textile/plastics, bulky waste, and incombustible waste was over 80%. Approximately 30% of Cr originated from plastic packaging. Finally, several MSW management scenarios showed that most metals are transferred to landfills and the leaching potential of metals to the environment is quite small.

Jung, C.H. [Laboratory of Solid Waste Disposal Engineering, Graduate School of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628 (Japan); Matsuto, T. [Laboratory of Solid Waste Disposal Engineering, Graduate School of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628 (Japan)]. E-mail: matsuto@eng.hokudai.ac.jp; Tanaka, N. [Laboratory of Solid Waste Disposal Engineering, Graduate School of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo 060-8628 (Japan)

2006-07-01T23:59:59.000Z

122

Study of the VOC emissions from a municipal solid waste storage pilot-scale cell: Comparison with biogases from municipal waste landfill site  

Science Conference Proceedings (OSTI)

Highlights: > Follow-up of the emission of VOCs in a municipal waste pilot-scale cell during the acidogenesis and acetogenesis phases. > Study from the very start of waste storage leading to a better understanding of the decomposition/degradation of waste. > Comparison of the results obtained on the pilot-scale cell with those from 3 biogases coming from the same landfill site. > A methodology of characterization for the progression of the stabilization/maturation of waste is finally proposed. - Abstract: The emission of volatile organic compounds (VOCs) from municipal solid waste stored in a pilot-scale cell containing 6.4 tonnes of waste (storage facility which is left open during the first period (40 days) and then closed with recirculation of leachates during a second period (100 days)) was followed by dynamic sampling on activated carbon and analysed by GC-MS after solvent extraction. This was done in order to know the VOC emissions before the installation of a methanogenesis process for the entire waste mass. The results, expressed in reference to toluene, were exploited during the whole study on all the analyzable VOCs: alcohols, ketones and esters, alkanes, benzenic and cyclic compounds, chlorinated compounds, terpene, and organic sulphides. The results of this study on the pilot-scale cell are then compared with those concerning three biogases from a municipal waste landfill: biogas (1) coming from waste cells being filled or recently closed, biogas (2) from all the waste storage cells on site, and biogas (3) which is a residual gas from old storage cells without aspiration of the gas. The analysis of the results obtained revealed: (i) a high emission of VOCs, principally alcohols, ketones and esters during the acidogenesis; (ii) a decrease in the alkane content and an increase in the terpene content were observed in the VOCs emitted during the production of methane; (iii) the production of heavier alkanes and an increase in the average number of carbon atoms per molecule of alkane with the progression of the stabilisation/maturation process were also observed. Previous studies have concentrated almost on the analysis of biogases from landfills. Our research aimed at gaining a more complete understanding of the decomposition/degradation of municipal solid waste by measuring the VOCs emitted from the very start of the landfill process i.e. during the acidogenesis and acetogenesis phases.

Chiriac, R., E-mail: rodica.chiriac@univ-lyon1.fr [Universite de Lyon, Universite Lyon 1, CNRS, UMR 5615, Laboratoire des Multimateriaux et Interfaces, 43 boulevard du 11 Novembre 1918, F-69622 Villeurbanne (France); De Araujos Morais, J. [Universite Federal de Paraiba, Campus I Departamento de Engenharia Civil e Ambiental, Joao Pessoa, Paraiba (Brazil); Carre, J. [Universite de Lyon, Universite Lyon 1, CNRS, UMR 5256, Institut de Recherche sur la Catalyse et l'Environnement, 43 boulevard du 11 Novembre 1918, F-69622 Villeurbanne (France); Bayard, R. [Universite de Lyon, INSA de Lyon, Laboratoire de Genie Civil et d'Ingenierie environnementale (LGCIE), F-69622 Villeurbanne (France); Chovelon, J.M. [Universite de Lyon, Universite Lyon 1, CNRS, UMR 5256, Institut de Recherche sur la Catalyse et l'Environnement, 43 boulevard du 11 Novembre 1918, F-69622 Villeurbanne (France); Gourdon, R. [Universite de Lyon, INSA de Lyon, Laboratoire de Genie Civil et d'Ingenierie environnementale (LGCIE), F-69622 Villeurbanne (France)

2011-11-15T23:59:59.000Z

123

Combustion of municipal solid wastes with oil shale in a circulating fluidized bed. Quarterly report ending March 31, 1996  

SciTech Connect

This document contains a progress report for the Project Description of Grant No. DE-FG01-94CE15612, {open_quotes}Develop a Combustion of Municipal Solid Waste with Oil Shale in Circulating Fluidized Bed{close_quotes}, dated September 2, 1994. The Project Description lists and describes six tasks, four of which are complete, and two others nearing completion. A summary of progress on each task is presented in this report.

1996-04-01T23:59:59.000Z

124

Integration of the informal sector into municipal solid waste management in the Philippines - What does it need?  

SciTech Connect

The integration of the informal sector into municipal solid waste management is a challenge many developing countries face. In Iloilo City, Philippines around 220 tons of municipal solid waste are collected every day and disposed at a 10 ha large dumpsite. In order to improve the local waste management system the Local Government decided to develop a new Waste Management Center with integrated landfill. However, the proposed area is adjacent to the presently used dumpsite where more than 300 waste pickers dwell and depend on waste picking as their source of livelihood. The Local Government recognized the hidden threat imposed by the waste picker's presence for this development project and proposed various measures to integrate the informal sector into the municipal solid waste management (MSWM) program. As a key intervention a Waste Workers Association, called USWAG Calahunan Livelihood Association Inc. (UCLA) was initiated and registered as a formal business enterprise in May 2009. Up to date, UCLA counts 240 members who commit to follow certain rules and to work within a team that jointly recovers wasted materials. As a cooperative they are empowered to explore new livelihood options such as the recovery of Alternative Fuels for commercial (cement industry) and household use, production of compost and making of handicrafts out of used packages. These activities do not only provide alternative livelihood for them but also lessen the generation of leachate and Greenhouse Gases (GHG) emissions from waste disposal, whereby the life time of the proposed new sanitary landfill can be extended likewise.

Paul, Johannes G., E-mail: jp.aht.p3@gmail.com [GIZ-AHT Project Office SWM4LGUs, c/o DENR, Iloilo City (Philippines); Arce-Jaque, Joan [GIZ-AHT Project Office SWM4LGUs, c/o DENR, Iloilo City (Philippines); Ravena, Neil; Villamor, Salome P. [General Service Office, City Government, Iloilo City (Philippines)

2012-11-15T23:59:59.000Z

125

Heat transfer between elastic solids with randomly rough surfaces  

E-Print Network (OSTI)

We study the heat transfer between elastic solids with randomly rough surfaces. We include both the heat transfer from the area of real contact, and the heat transfer between the surfaces in the noncontact regions. We apply a recently developed contact mechanics theory, which accounts for the hierarchical nature of the contact between solids with roughness on many different length scales. For elastic contact, at the highest (atomic) resolution the area of real contact typically consists of atomic (nanometer) sized regions, and we discuss the implications of this for the heat transfer. For solids with very smooth surfaces, as is typical in many modern engineering applications, the interfacial separation in the non-contact regions will be very small, and for this case we show the importance of the radiative heat transfer associated with the evanescent electromagnetic waves which exist outside of all bodies.

B. N. J. Persson; B. Lorenz; A. I. Volokitin

2009-08-27T23:59:59.000Z

126

Nitrogen availability and leaching from soil amended with municipal solid waste compost  

Science Conference Proceedings (OSTI)

Beneficial use of municipal solid waste compost depends on identifying a management strategy that supports crop production and protects water quality. Effects of compost and N fertilizer management strategies on corn (Zea mays L.) yield and NO{sub 3}{sup {minus}}-N leaching were evaluated in a 3-yr study on a Hubbard loamy sand soil. Two composts were each applied at either 90 Mg ha{sup {minus}1} yr{sup {minus}1} from 1993 to 1995, or at 270 Mg ha{sup {minus}1} in one application in 1993. The compost and non-amended plots were side dressed annually with N fertilizer as urea at 0, 125, and 250 kg ha{sup {minus}1}. Biochemical properties of the compost as well as compost management strongly affected crop response and fate of N. Compost increased grain yield with no significant yield response to N fertilizer with the single compost application in Year 1 and the annual compost application in Year 3. Plant N uptake increased with N fertilizer rate, except in the 270 Mg ha{sup {minus}1} compost treatments in Year 1. Over the 3-yr period, NO{sub 3}{sup {minus}}-N leaching with the 270 Mg ha{sup {minus}1} compost application was 1.8 times greater compared to that with the annual application. The estimated N mineralization ranged from 0 to 12% and 3 to 6% in the annual and single compost addition, respectively. Under the conditions of this study, annual compost application with reduced supplemental N fertilizer was the best management strategy to reach optimum crop yield while minimizing NO{sub 3}{sup {minus}}-N leaching losses.

Mamo, M.; Rosen, C.J.; Halbach, T.R.

1999-08-01T23:59:59.000Z

127

RD & D priorities for energy production and resource conservation from municipal solid waste  

Science Conference Proceedings (OSTI)

This report identifies research, development, and demonstration (RD&D) needs and priorities associated with municipal solid waste (MSW) management technologies that conserve or produce energy or resources. The changing character of MSW waste management and the public`s heightened awareness of its real and perceived benefits and costs creates opportunities for RD&D in MSW technologies. Increased recycling, for example, creates new opportunities for energy, chemicals, and materials recovery. New technologies to control and monitor emissions from MSW combustion facilities are available for further improvement or application. Furthermore, emerging waste-to-energy technologies may offer environmental, economic, and other advantages. Given these developments, DOE identified a need to assess the RD&D needs and pdodties and carefully target RD&D efforts to help solve the carbon`s waste management problem and further the National Energy Strategy. This report presents such an assessment. It identifies and Documents RD&D needs and priorities in the broad area of MSW resource . recovery, focusing on efforts to make MSW management technologies commercially viable or to improve their commercial deployment over a 5 to l0 year period. Panels of technical experts identifies 279 RD&D needs in 12 technology areas, ranking about one-fifth of these needs as priorities. A ``Peer Review Group`` identified mass-burn combustion, ``systems studies,`` landfill gas, and ash utilization and disposal as high priority areas for RD&D based on cost and the impacts of further RD&D. The results of this assessment are intended to provide guidance to DOE concerning possible future RD&D projects.

Not Available

1992-08-01T23:59:59.000Z

128

Toxicity mitigation and solidification of municipal solid waste incinerator fly ash using alkaline activated coal ash  

Science Conference Proceedings (OSTI)

Highlights: Black-Right-Pointing-Pointer Incinerator fly ash (IFA) is added to an alkali activated coal fly ash (CFA) matrix. Black-Right-Pointing-Pointer Means of stabilizing the incinerator ash for use in construction applications. Black-Right-Pointing-Pointer Concrete made from IFA, CFA and IFA-CFA mixes was chemically characterized. Black-Right-Pointing-Pointer Environmentally friendly solution to IFA disposal by reducing its toxicity levels. - Abstract: Municipal solid waste (MSW) incineration is a common and effective practice to reduce the volume of solid waste in urban areas. However, the byproduct of this process is a fly ash (IFA), which contains large quantities of toxic contaminants. The purpose of this research study was to analyze the chemical, physical and mechanical behaviors resulting from the gradual introduction of IFA to an alkaline activated coal fly ash (CFA) matrix, as a mean of stabilizing the incinerator ash for use in industrial construction applications, where human exposure potential is limited. IFA and CFA were analyzed via X-ray fluorescence (XRF), X-ray diffraction (XRD) and Inductive coupled plasma (ICP) to obtain a full chemical analysis of the samples, its crystallographic characteristics and a detailed count of the eight heavy metals contemplated in US Title 40 of the Code of Federal Regulations (40 CFR). The particle size distribution of IFA and CFA was also recorded. EPA's Toxicity Characteristic Leaching Procedure (TCLP) was followed to monitor the leachability of the contaminants before and after the activation. Also images obtained via Scanning Electron Microscopy (SEM), before and after the activation, are presented. Concrete made from IFA, CFA and IFA-CFA mixes was subjected to a full mechanical characterization; tests include compressive strength, flexural strength, elastic modulus, Poisson's ratio and setting time. The leachable heavy metal contents (except for Se) were below the maximum allowable limits and in many cases even below the reporting limit. The leachable Chromium was reduced from 0.153 down to 0.0045 mg/L, Arsenic from 0.256 down to 0.132 mg/L, Selenium from 1.05 down to 0.29 mg/L, Silver from 0.011 down to .001 mg/L, Barium from 2.06 down to 0.314 mg/L and Mercury from 0.007 down to 0.001 mg/L. Although the leachable Cd exhibited an increase from 0.49 up to 0.805 mg/L and Pd from 0.002 up to 0.029 mg/L, these were well below the maximum limits of 1.00 and 5.00 mg/L, respectively.

Ivan Diaz-Loya, E. [Alternative Cementitious Binders Laboratory (ACBL), Department of Civil Engineering, Louisiana Tech University, Ruston, LA 71272 (United States); Allouche, Erez N., E-mail: allouche@latech.edu [Alternative Cementitious Binders Laboratory (ACBL), Department of Civil Engineering, Louisiana Tech University, Ruston, LA 71272 (United States); Eklund, Sven; Joshi, Anupam R. [Department of Chemistry, Louisiana Tech University, Ruston, LA 71272 (United States); Kupwade-Patil, Kunal [Alternative Cementitious Binders Laboratory (ACBL), Department of Civil Engineering, Louisiana Tech University, Ruston, LA 71272 (United States)

2012-08-15T23:59:59.000Z

129

Combustion of municipal solid wastes with oil shale in a circulating fluidized bed. Quarterly report, quarter ending December 31, 1995  

DOE Green Energy (OSTI)

The objective of this project is to demonstrate that cocombustion of municipal solid waste and oil shale can reduce emissions of gaseous pollutants (SO{sub 2} and HCl) to acceptable levels. Tests in 6- and 15-inch units showed that the oil shale absorbs acid gas pollutants and produces an ash which could be, at the least, disposed of in a normal landfill. Further analysis of the results are underway to estimate scale-up to commercial size. Additional work will be done to evaluate the cementitious properties of oil shale ash.

NONE

1996-01-01T23:59:59.000Z

130

Solute transport under steady and transient conditions in biodegraded municipal solid waste  

E-Print Network (OSTI)

The transport of a conservative tracer (lithium) in a large (3.5 m3) undisturbed municipal solid waste sample has been investigated under steady and fully transient conditions using a simple model. The model comprises a kinematic wave approximation for water movement, presented in a previous paper, and a strict convective solute flux law. The waste medium is conceptualized as a three-domain system consisting of a mobile domain (channels), an immobile fast domain, and an immobile slow domain. The mobile domain constitutes only a minor fraction of the medium, and the access to the major part of medium is constrained by diffusive transport. Thus the system is in a state of physical nonequilibrium. The fast immobile domain is the part of the matrix which surrounds the channels and forms the boundary between the channels and the matrix. Owing to its exposure to mobile water, which enhances the biodegradation process, this domain is assumed to be more porous and loose in its structure and therefore to respond faster to a change in solute concentration in the mobile domain compared to the regions deep inside the matrix. The diffusive mass exchange between the domains is modeled with two first-order mass transfer expressions coupled in series. Under transient conditions the system will also be in a state of hydraulic nonequilibrium. Hydraulic gradients build up between the channel domain and the matrix in response to the water input events. The gradients will govern a reversible flow and convective transport between the domains, here represented as a source/sink term in the governing equation. The model has been used to interpret and compare the results from a steady state experiment and an unsteady state experiment. By solely adjusting the size of the fraction of the immobile fast domain that is active in transferring solute, the model is capable of accurately reproducing the measured outflow breakthrough curves for both the steady and unsteady state experiments. During transient conditions the fraction of the immobile fast domain that is active in transferring solute is found to be about 65% larger than that under steady state conditions. It is therefore concluded that the water input pattern governs the size of the fraction of the immobile fast domain which, in turn, governs the solute residence time in the solid waste. It can be concluded that the contaminant transport process in landfills is likely to be in a state of both physical, hydraulic, and chemical nonequilibrium. The transport process for a conservative solute is here shown to be dominated by convective transport in the channels and a fast diffusive mass exchange with the surrounding matrix. This may imply that the observed leachate quality from landfills mainly reflects the biochemical conditions in these regions. The water input pattern is of great importance for the transport process since it governs the size of the fraction of the immobile fast domain which is active in transferring solute. This may be the reason for leachate quality to be seasonally or water flux dependent, which has been observed in several investigations. The result also has a significant practical implication for efforts to enhance the biodegradation process in landfills by recycling of the leachate.

Bendz, David; Singh, Vijay P.

1999-08-01T23:59:59.000Z

131

COMPACTING BIOMASS AND MUNICIPAL SOLID WASTES TO FORM AND UPGRADED FUEL  

DOE Green Energy (OSTI)

Biomass waste materials exist in large quantity in every city and in numerous industrial plants such as wood processing plants and waste paper collection centers. Through minimum processing, such waste materials can be turned into a solid fuel for combustion at existing coal-fired power plants. Use of such biomass fuel reduces the amount of coal used, and hence reduces the greenhouse effect and global warming, while at the same time it reduces the use of land for landfill and the associated problems. The carbon-dioxide resulting from burning biomass fuel is recycled through plant growth and hence does not contribute to global warming. Biomass fuel also contains little sulfur and hence does not contribute to acid rain problems. Notwithstanding the environmental desirability of using biomass waste materials, not much of them are used currently due to the need to densify the waste materials and the high cost of conventional methods of densification such as pelletizing and briquetting. The purpose of this project was to test a unique new method of biomass densification developed from recent research in coal log pipeline (CLP). The new method can produce large agglomerates of biomass materials called ''biomass logs'' which are more than 100 times larger and 30% denser than conventional ''pellets'' or ''briquettes''. The Phase I project was to perform extensive laboratory tests and an economic analysis to determine the technical and economic feasibility of the biomass log fuel (BLF). A variety of biomass waste materials, including wood processing residues such as sawdust, mulch and chips of various types of wood, combustibles that are found in municipal solid waste stream such as paper, plastics and textiles, energy crops including willows and switch grass, and yard waste including tree trimmings, fallen leaves, and lawn grass, were tested by using this new compaction technology developed at Capsule Pipeline Research Center (CPRC), University of Missouri-Columbia (MU). The compaction conditions, including compaction pressure, pressure holding time, back pressure, moisture content, particle size and shape, piston and mold geometry and roughness, and binder for the materials were studied and optimized. The properties of the compacted products--biomass logs--were evaluated in terms of physical, mechanical, and combustion characteristics. An economic analysis of this technology for anticipated future commercial operations was performed. It was found that the compaction pressure and the moisture content of the biomass materials are critical for producing high-quality biomass logs. For most biomass materials, dense and strong logs can be produced under room temperature without binder and at a pressure of 70 MPa (10,000 psi), approximately. A few types of the materials tested such as sawdust and grass need a minimum pressure of 100 MPa (15,000 psi) in order to produce good logs. The appropriate moisture range for compacting waste paper into good logs is 5-20%, and the optimum moisture is in the neighborhood of 13%. For the woody materials and yard waste, the appropriate moisture range is narrower: 5-13%, and the optimum is 8-9%. The compacted logs have a dry density of 0.8 to 1.0 g/cm{sup 3}, corresponding to a wet density of 0.9 to 1.1 g/cm{sup 3}, approximately. The logs have high strength and high resistance to impact and abrasion, but are feeble to water and hence need to be protected from water or rain. They also have good long-term performance under normal environmental conditions, and can be stored for a long time without significant deterioration. Such high-density and high-strength logs not only facilitate handling, transportation, and storage, but also increase the energy content of biomass per unit volume. After being transported to power plants and crushed, the biomass logs can be co-fired with coal to generate electricity.

Henry Liu; Yadong Li

2000-11-01T23:59:59.000Z

132

Rapid heating of solid density material by a petawatt laser  

Science Conference Proceedings (OSTI)

Time-resolved x-ray spectra from solid targets irradiated by the VULCAN Petawatt laser focused to 10{sup 20} W cm{sup -2} show that material at solid density is heated to temperatures above 500 eV to a depth of about 15 {mu}m and for a duration of more than 30 ps. Modeling with the implicit hybrid plasma code LSP shows that the heating is sensitive to the laser prepulse through resistive inhibition of the laser accelerated electrons in the blow off layer.

Evans, R.G.; Clark, E.L.; Eagleton, R.T.; Dunne, A.M.; Edwards, R.D.; Garbett, W.J.; Goldsack, T.J.; James, S.; Smith, C.C.; Thomas, B.R.; Clarke, R.; Neely, D.J.; Rose, S.J. [AWE plc, Aldermaston, Reading, RG7 4PR (United Kingdom); Central LaserFacility, CCLRC Rutherford Appleton Laboratory (United Kingdom); Clarendon Laboratory, University of Oxford (United Kingdom)

2005-05-09T23:59:59.000Z

133

Industrial Heat Pumps Using Solid/Vapor Working Fluids  

E-Print Network (OSTI)

Industrial heat pumps have the potential to reduce the operating costs of chemical and heat treating processes in the chemical, petroleum, paper, dairy, and many other industries. The cost development of fossil fuel and other prime energy require excellent efficiency/cost ratios and hardware designs adaptable to specific process needs, in order to compete with vapor re-compression recovery systems. The state-of-the-art heat pump equipment employing liquid/vapor working fluids fulfills the requirements only in some applications. The employment of solid/vapor complex compounds leads to more cost effective heat recovery, which is due to simple hardware with no moving parts, extraordinary low maintenance effort, excellent temperature lifts avoiding the need of two-stage systems, and low first cost. This paper describes the advantages and disadvantages of solid/vapor working media.

Rockenfeller, U.

1986-06-01T23:59:59.000Z

134

Time-resolved ellipsometry for studies of heat transfer at liquid/solid and gas/solid interfaces  

E-Print Network (OSTI)

partly controlled by the rate of heat transfer across the interface. Heat moving from the metal film is heated by 10 K using an ultrafast optical pump pulse; the subsequent changes of the phase differenceTime-resolved ellipsometry for studies of heat transfer at liquid/solid and gas/solid interfaces

Granick, Steve

135

Data summary of municipal solid waste management alternatives. Volume 11, Alphabetically indexed bibliography  

Science Conference Proceedings (OSTI)

This appendix contains the alphabetically indexed bibliography for the complete group of reports on municipal waste management alternatives. The references are listed for each of the following topics: mass burn technologies, RDF technologies, fluidized-bed combustion, pyrolysis and gasification of MSW, materials recovery- recycling technologies, sanitary landfills, composting, and anaerobic digestion of MSW.

Not Available

1992-10-01T23:59:59.000Z

136

Clean energy from municipal solid waste. ERIP technical progress report {number_sign}6  

DOE Green Energy (OSTI)

The ground carbonized RDF slurry from the grinding trials at IKA Works at approximately 50 wt.% solids was sealed in drums and shipped to the Energy and Environmental Research Corporation (EER) for the dioxin/furan and trace heavy metal combustion tests. In addition, a fuel characterization and trace component analysis was completed for this final carbonized RDF slurry fuel. This final fuel was a blend of several fuels from the pilot scale slurry carbonization experiments. As can be seen from the data, the final carbonized RDF has an exceptional heating value and volatile matter content. In addition, trace components are significantly lower than the raw RDF pellets. The report summarizes results from combustion tests and air pollution monitoring of these tests. For the upcoming time period 10/96--01/97, it is anticipated that the analysis of the dioxin/furan and trace heavy metal combustion test will be completed. This analysis includes rheology and particle size distribution analysis of the carbonized RDF slurry fuel, carbon content and TCLP of the combustion ash, trace heavy metal balances around combustor, and dioxin/furan emissions. Finally, the slurry carbonization computer model and computer simulations will be completed in the next reporting period (including the waste water treatment subsystem). Based upon this computer model, initial economic estimates and optimizations of the slurry carbonization process will be completed in the next reporting period.

NONE

1996-10-08T23:59:59.000Z

137

Experimental performance of solid-gas chemical heat pump in solar chemical heat pump dryer  

Science Conference Proceedings (OSTI)

A solar assisted chemical heat pump dryer has been designed, fabricated and tested. The performance of the system has been studied under the meteorological conditions of Malaysia. The system consists of four mean components: solar collector (evacuated ... Keywords: coefficient of performance, drying, energy density, evacuated tubes solar collector, reactor temperature, solid gas chemical heat pump

M. Ibrahim; K. Sopian; A. S. Hussein; W. R. W. Daud; A. Zaharim

2009-02-01T23:59:59.000Z

138

Two-year performance by evapotranspiration covers for municipal solid waste landfills in northwest Ohio  

Science Conference Proceedings (OSTI)

Highlights: Black-Right-Pointing-Pointer All ET covers produced rates of percolation less than 32 cm yr{sup -1}, the maximum allowable rate by the Ohio EPA. Black-Right-Pointing-Pointer Dredged sediment provided sufficient water storage and promoted growth by native plant species. Black-Right-Pointing-Pointer Native plant mixtures attained acceptable rates of evapotranspiration throughout the growing season. - Abstract: Evapotranspiration (ET) covers have gained interest as an alternative to conventional covers for the closure of municipal solid waste (MSW) landfills because they are less costly to construct and are expected to have a longer service life. Whereas ET covers have gained acceptance in arid and semi-arid regions (defined by a precipitation (P) to potential evapotranspiration (PET) ratio less than 0.75) by meeting performance standards (e.g. rate of percolation), it remains unclear whether they are suitable for humid regions (P:PET greater than 0.75). The goal of this project is to extend their application to northwest Ohio (P:PET equals 1.29) by designing covers that produce a rate of percolation less than 32 cm yr{sup -1}, the maximum acceptable rate by the Ohio Environmental Protection Agency (OEPA). Test ET covers were constructed in drainage lysimeters (1.52 m diameter, 1.52 m depth) using dredged sediment amended with organic material and consisted of immature (I, plants seeded onto soil) or mature (M, plants transferred from a restored tall-grass prairie) plant mixtures. The water balance for the ET covers was monitored from June 2009 to June 2011, which included measured precipitation and percolation, and estimated soil water storage and evapotranspiration. Precipitation was applied at a rate of 94 cm yr{sup -1} in the first year and at rate of 69 cm yr{sup -1} in the second year. During the first year, covers with the M plant mixture produced noticeably less percolation (4 cm) than covers with the I plant mixture (17 cm). However, during the second year, covers with the M plant mixture produced considerably more percolation (10 cm) than covers with the I plant mixture (3 cm). This is likely due to a decrease in the aboveground biomass for the M plant mixture from year 1 (1008 g m{sup -2}) to year 2 (794 g m{sup -2}) and an increase for the I plant mixture from year 1 (644 g m{sup -2}) to year 2 (1314 g m{sup -2}). Over the 2-year period, the mean annual rates of percolation for the covers with the M and I plant mixtures were 7 and 8 cm yr{sup -1}, which are below the OEPA standard. The results suggest the application of ET covers be extended to northwest Ohio and other humid regions.

Barnswell, Kristopher D., E-mail: kristopher.barnswell2@rockets.utoledo.edu [Department of Environmental Sciences, University of Toledo, Lake Erie Center, 6200 Bayshore Rd., Oregon, OH 43616 (United States); Dwyer, Daryl F., E-mail: daryl.dwyer@utoledo.edu [Department of Environmental Sciences, University of Toledo, 2801 W. Bancroft, Mail Stop 604, Toledo, OH 43606 (United States)

2012-12-15T23:59:59.000Z

139

Allocating Municipal Solid Waste to Renewable and Non-renewable Energy  

U.S. Energy Information Administration (EIA)

Plastic. MillionBtus to total. Heat Content. Btus. Total Btus/Total Tons. ... Containers & Packaging. Material Group (million tons)a (million Btu per ton) b. Heat ...

140

The Potential of Cellulosic Ethanol Production from Municipal Solid Waste: A Technical and Economic Evaluation  

E-Print Network (OSTI)

process streams. Handb. Bioethanol:395-415. 10. Ehrman T.solid waste used as bioethanol sources and its relatedof cellulosic biomass into bioethanol as an alternative

Shi, Jian; Ebrik, Mirvat; Yang, Bin; Wyman, Charles E.

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Corner heating in rectangular solid oxide electrochemical cell generators  

DOE Patents (OSTI)

Disclosed is an improvement in a solid oxide electrochemical cell generator 1 having a rectangular design with four sides that meet at corners, and containing multiplicity of electrically connected fuel cells 11, where a fuel gas is passed over one side of said cells and an oxygen containing gas is passed into said cells, and said fuel is burned to form heat, electricity, and an exhaust gas. The improvement comprises passing the exhaust gases over the multiplicity of cells 11 in such a way that more of the heat in said exhaust gases flows at the corners of the generator, such as through channels 19.

Reichner, Philip (Plum Boro, PA)

1989-01-01T23:59:59.000Z

142

Life-cycle assessment of municipal solid waste management alternatives with consideration of uncertainty: SIWMS development and application  

Science Conference Proceedings (OSTI)

This paper describes the development and application of the Stochastic Integrated Waste Management Simulator (SIWMS) model. SIWMS provides a detailed view of the environmental impacts and associated costs of municipal solid waste (MSW) management alternatives under conditions of uncertainty. The model follows a life-cycle inventory approach extended with compensatory systems to provide more equitable bases for comparing different alternatives. Economic performance is measured by the net present value. The model is verified against four publicly available models under deterministic conditions and then used to study the impact of uncertainty on Sydney's MSW management 'best practices'. Uncertainty has a significant effect on all impact categories. The greatest effect is observed in the global warming category where a reversal of impact direction is predicted. The reliability of the system is most sensitive to uncertainties in the waste processing and disposal. The results highlight the importance of incorporating uncertainty at all stages to better understand the behaviour of the MSW system.

El Hanandeh, Ali, E-mail: alel5804@uni.sydney.edu.a [School of Civil Engineering, Building J05, University of Sydney NSW 2006 (Australia); El-Zein, Abbas [School of Civil Engineering, Building J05, University of Sydney NSW 2006 (Australia)

2010-05-15T23:59:59.000Z

143

Combustion of municipal solid wastes with oil shale in a circulating fluidized bed. Quarterly report, quarter ending 31 December 1994  

DOE Green Energy (OSTI)

The test plan is designed to demonstrate that oil shale co-combusted with municipal solid waste (MSW) can reduce gaseous pollutants (SO{sub 2}, CO) to acceptable levels (90%+ reduction) and produce a cementitious ash which will, at a minimum, be acceptable in normal land fills. The small-scale combustion testing will be accomplished in a 6-in. circulating fluid bed combustor (CFBC) at Hazen Research Laboratories. This work will be patterned after the study the authors conducted in 1988 when coal and oil shale were co-combusted in a program sponsored by the Electric Power Research Institute. The specific purpose of the test program will be to: determine the required ratio of oil shale to MSW by determining the ratio of absorbent to pollutant (A/P); determine the effect of temperature and resident time in the reactor; and determine if kinetic model developed for coal/oil shale mixture is applicable.

Not Available

1995-01-01T23:59:59.000Z

144

Anaerobic digestion of organic fraction of municipal solid waste combining two pretreatment modalities, high temperature microwave and hydrogen peroxide  

SciTech Connect

Highlights: Black-Right-Pointing-Pointer Microwave and H{sub 2}O{sub 2} pretreatment were studied to enhance anaerobic digestion of organic waste. Black-Right-Pointing-Pointer The whole waste pretreated at 115 Degree-Sign C or 145 Degree-Sign C had the highest biogas production. Black-Right-Pointing-Pointer Biogas production of the whole waste decreased at 175 Degree-Sign C due to formation of refractory compounds. Black-Right-Pointing-Pointer Pretreatment to 145 Degree-Sign C and 175 Degree-Sign C were the best when considering only the free liquid fraction. Black-Right-Pointing-Pointer H{sub 2}O{sub 2} pretreatment had a lag phase and the biogas production was not higher than MW pretreated samples. - Abstract: In order to enhance anaerobic digestion (AD) of the organic fraction of municipal solid waste (OFMSW), pretreatment combining two modalities, microwave (MW) heating in presence or absence of hydrogen peroxide (H{sub 2}O{sub 2}) were investigated. The main pretreatment variables affecting the characteristics of the OFMSW were temperature (T) via MW irradiation and supplemental water additions of 20% and 30% (SWA20 and SW30). Subsequently, the focus of this study was to evaluate mesophilic batch AD performance in terms of biogas production, as well as changes in the characteristics of the OFMSW post digestion. A high MW induced temperature range (115-175 Degree-Sign C) was applied, using sealed vessels and a bench scale MW unit equipped with temperature and pressure controls. Biochemical methane potential (BMP) tests were conducted on the whole OFMSW as well as the liquid fractions. The whole OFMSW pretreated at 115 Degree-Sign C and 145 Degree-Sign C showed 4-7% improvement in biogas production over untreated OFMSW (control). When pretreated at 175 Degree-Sign C, biogas production decreased due to formation of refractory compounds, inhibiting the digestion. For the liquid fraction of OFMSW, the effect of pretreatment on the cumulative biogas production (CBP) was more pronounced for SWA20 at 145 Degree-Sign C, with a 26% increase in biogas production after 8 days of digestion, compared to the control. When considering the increased substrate availability in the liquid fraction after MW pretreatment, a 78% improvement in biogas production vs. the control was achieved. Combining MW and H{sub 2}O{sub 2} modalities did not have a positive impact on OFMSW stabilization and enhanced biogas production. In general, all samples pretreated with H{sub 2}O{sub 2} displayed a long lag phase and the CBP was usually lower than MW irradiated only samples. First order rate constant was calculated.

Shahriari, Haleh, E-mail: haleh.shahriari@gmail.com [Department of Civil Engineering, University of Ottawa, 161 Louis Pasteur St., P.O. Box 450, Stn. A, Ottawa, ON, K1N 6N5 (Canada); Warith, Mostafa [Department of Civil Engineering, University of Ottawa, 161 Louis Pasteur St., P.O. Box 450, Stn. A, Ottawa, ON, K1N 6N5 (Canada); Hamoda, Mohamed [Department of Environmental Technology and Management, Kuwait University, P.O. Box 5969, Safat 13060 (Kuwait); Kennedy, Kevin J. [Department of Civil Engineering, University of Ottawa, 161 Louis Pasteur St., P.O. Box 450, Stn. A, Ottawa, ON, K1N 6N5 (Canada)

2012-01-15T23:59:59.000Z

145

Toxicity characteristic leaching procedure fails to extract oxoanion-forming elements that are extracted by municipal solid waste leachates  

Science Conference Proceedings (OSTI)

US EPA and state regulatory agencies rely on standard extraction tests to identify wastes that have the potential to contaminate surface water or groundwater. To evaluate the predictive abilities of these extraction tests, the Toxicity Characteristic Leaching Procedure (TCLP), the Waste Extraction Test (WET), and the Synthetic Precipitation Leaching Procedure (SPLP) were compared with actual municipal solid waste leachates (MSWLs) for their ability to extract regulated elements from a variety of industrial solid wastes in short- and long-term extractions. Short-term extractions used MSWLs from a variety of California landfills. Long-term sequential extractions simulated longer term leaching, as might occur in MSW landfills. For most regulated elements, the TCLP roughly predicted the maximum concentrations extracted by the MSWLs. For regulated elements that form oxoanions (e.g., Sb, As, Mo, Se, V), however the TCLP underpredicted the levels extracted by the MSWL. None of the standard tests adequately predicted these levels. The results emphasize the need for better standardized techniques to identify wastes that have the potential to contaminate groundwater with oxoanion-forming elements, particularly arsenic.

Hooper, K.; Iskander, M.; Sivia, G. [California Dept. of Toxic Substances Control, Berkeley, CA (United States). Hazardous Materials Lab.] [and others

1998-12-01T23:59:59.000Z

146

Environmental & economical optimization for municipal solid waste collection problems, a modeling and algorithmic approach case study  

Science Conference Proceedings (OSTI)

Increasing environmental concerns and interests in material and energy conservation have lead to increasing advancement in the management of solid waste over the past two decades. The field of modeling of waste management system, as opposed to the modeling ... Keywords: CO2 emission, MSW collection and routing, MSW costs analysis, network design

F. Rhoma; Z. Zhang; Y. Luo; B. Noche

2010-05-01T23:59:59.000Z

147

Heating of solid earthen material, measuring moisture and resistivity  

DOE Patents (OSTI)

The present invention includes a method of treating solid earthen material having volatile, semi-volatile, and non-volatile contaminants that utilizes electrical energy. A plurality of electrodes are inserted into a region of earthen material to be treated in a selected geometric pattern. Varying phase and voltages configurations are applied to corresponding electrodes to achieve heating, physical phase changes, and the placement of substances within the treatment region. Additionally, treatment mediums can be added to either treat the contamination within the soil or to restrict their mobility.

Heath, William O. (Richland, WA); Gauglitz, Phillip A. (Richland, WA); Pillay, Gautam (Richland, WA); Bergsman, Theresa M. (Richland, WA); Eschbach, Eugene A. (Richland, WA); Goheen, Steven C. (Richland, WA); Richardson, Richard L. (West Richland, WA); Roberts, Janet S. (Pasco, WA); Schalla, Ronald (Kennewick, WA)

1996-01-01T23:59:59.000Z

148

Heating of solid earthen material, measuring moisture and resistivity  

DOE Patents (OSTI)

The present invention includes a method of treating solid earthen material having volatile, semi-volatile, and non-volatile contaminants that utilizes electrical energy. A plurality of electrodes are inserted into a region of earthen material to be treated in a selected geometric pattern. Varying phase and voltages configurations are applied to corresponding electrodes to achieve heating, physical phase changes, and the placement of substances within the treatment region. Additionally, treatment mediums can be added to either treat the contamination within the soil or to restrict their mobility. 29 figs.

Heath, W.O.; Gauglitz, P.A.; Pillay, G.; Bergsman, T.M.; Eschbach, E.A.; Goheen, S.C.; Richardson, R.L.; Roberts, J.S.; Schalla, R.

1996-08-13T23:59:59.000Z

149

Heating of solid earthen material, measuring moisture and resistivity  

DOE Patents (OSTI)

The present invention includes a method of treating solid earthen material having volatile, semi-volatile, and non-volatile contaminants. Six electrodes are inserted into a region of earthen material to be treated in a substantially equilateral hexagonal arrangement. Six phases of voltages are applied to corresponding electrodes. The voltages are adjusted within a first range of voltages to create multiple current paths between pairs of the electrodes. The current paths are evenly distributed throughout the region defined by the electrodes and therefore uniformly heat the region. The region of earthen material is heated to a temperature sufficient to substantially remove volatile and semi-volatile contaminants by promoting microbial action. This temperature is less than a melting temperature of the earthen material. 13 figs.

Heath, W.O.; Richardson, R.L.; Goheen, S.C.

1994-07-19T23:59:59.000Z

150

Site hydrogeologic/geotechnical characterization report for Site B new municipal solid waste landfill  

Science Conference Proceedings (OSTI)

This Site Hydrogeologic/Geotechnical Characterization Report (SHCR) presents the results of a comprehensive study conducted on a proposed solid waste landfill site, identified herein as Site B, at the Savannah River Site (SRS). This report is intended to satisfy all requirements of the South Carolina Department of Health and Environmental Control (SCDHEC) with regard to landfill siting requirements and ground water and environmental protection. In addition, this report provides substantial geotechnical data pertinent to the landfill design process.

Reynolds, R.; Nowacki, P.

1991-04-01T23:59:59.000Z

151

Clean energy from municipal solid waste. ERIP Technical progress report No. 2  

SciTech Connect

Progress for the period July 1995 -- October 1995 for the slurry carbonization plant is described. Topics addressed include analytical results of carbonization of RDF, regression analysis of reactor temperature versus heating value of RDF fuel, and progress on reducing chlorine content of the fuels.

Klosky, M.

1995-10-02T23:59:59.000Z

152

Evaluation of oxygen utilization as an indicator of municipal solid-waste compost stability  

Science Conference Proceedings (OSTI)

This research evaluated oxygen utilization parameters as indicators of MSW compost stability. Parameters evaluated were the oxygen utilization rate (OUR), specific oxygen uptake rate (SOUR), five-day biochemical oxygen demand, and chemical oxygen demand. In addition, other suggested indicators of stability were investigated including percent volatile solids, volatile solids reduction, nitrogen content, carbon: nitrogen ratio, and reheating potential (RP). OUR is a measure of the rate of oxygen utilization by the microorganisms in the decomposition of organic matter in compost. OUR was observed to be sensitive to the degree of stabilization and decreased with increasing compost age and stability. OUR values near zero indicate that the compost microorganisms are in a state of endogenous respiration, which is characteristic of a stable compost. Therefore, OUR is an excellent indicator of stability. A number of disadvantages are associated with OUR for practical application. Therefore, other parameters were evaluated as indicators of stability based on their statistical correlation to OUR. RP exhibited the strongest correlation to OUR. In combination, RP and SOUR were the two parameters which exhibited the strongest correlation to OUR. OUR, RP, and SOUR are all measures of microbial activity which reflect the degree of organic decomposition, and therefore, stability. Based on the results of this research; OUR, RP, and SOUR are useful parameters in assessing compost stability.

Zimmerman, R.A.

1991-01-01T23:59:59.000Z

153

The estimation of N{sub 2}O emissions from municipal solid waste incineration facilities: The Korea case  

Science Conference Proceedings (OSTI)

The greenhouse gases (GHGs) generated in municipal solid waste (MSW) incineration are carbon dioxide (CO{sub 2}), methane (CH{sub 4}), and nitrous oxide (N{sub 2}O). In South Korea case, the total of GHGs from the waste incineration facilities has been increasing at an annual rate 10%. In these view, waste incineration facilities should consider to reduce GHG emissions. This study is designed to estimate the N{sub 2}O emission factors from MSW incineration plants, and calculate the N{sub 2}O emissions based on these factors. The three MSW incinerators examined in this study were either stoker or both stoker and rotary kiln facilities. The N{sub 2}O concentrations from the MSW incinerators were measured using gas chromatography-electron capture detection (GC-ECD) equipment. The average of the N{sub 2}O emission factors for the M01 plant, M02 plant, and M03 plant are 71, 75, and 153 g-N{sub 2}O/ton-waste, respectively. These results showed a significant difference from the default values of the intergovernmental panel on climate change (IPCC), while approaching those values derived in Japan and Germany. Furthermore, comparing the results of this study to the Korea Energy Economics Institute (KEEI) (2007) data on waste incineration, N{sub 2}O emissions from MSW incineration comprised 19% of the total N{sub 2}O emissions.

Park, Sangwon; Choi, Jun-Ho [Department of Chemical and Biomolecular Engineering, Yonsei University, 262 Seongsanno, Seodaemun-gu, Seoul 120-749 (Korea, Republic of); Park, Jinwon, E-mail: jwpark@yonsei.ac.kr [Department of Chemical and Biomolecular Engineering, Yonsei University, 262 Seongsanno, Seodaemun-gu, Seoul 120-749 (Korea, Republic of)

2011-08-15T23:59:59.000Z

154

Solar-heated municipal swimming pools, a case study: Dade County, Florida  

DOE Green Energy (OSTI)

The experience of installing a solar energy system to heat the water in the swimming pool in one of Dade County, Florida's major parks is described and the mechanics of solar heated swimming pools are explained. The solar heating system consists of 216 unglazed polypropylene tube collectors, a differential thermostat, and the distribution system. The performance and economics of the system are discussed as well as future plants. (LEW)

Levin, M.

1981-09-01T23:59:59.000Z

155

Municipal waste processing apparatus  

DOE Patents (OSTI)

This invention relates to apparatus for processing municipal waste, and more particularly to vibrating mesh screen conveyor systems for removing grit, glass, and other noncombustible materials from dry municipal waste. Municipal waste must be properly processed and disposed of so that it does not create health risks to the community. Generally, municipal waste, which may be collected in garbage trucks, dumpsters, or the like, is deposited in processing areas such as landfills. Land and environmental controls imposed on landfill operators by governmental bodies have increased in recent years, however, making landfill disposal of solid waste materials more expensive. 6 figs.

Mayberry, J.L.

1988-04-13T23:59:59.000Z

156

Examining the effectiveness of municipal solid waste management systems: An integrated cost-benefit analysis perspective with a financial cost modeling in Taiwan  

Science Conference Proceedings (OSTI)

In order to develop a sound material-cycle society, cost-effective municipal solid waste (MSW) management systems are required for the municipalities in the context of the integrated accounting system for MSW management. Firstly, this paper attempts to establish an integrated cost-benefit analysis (CBA) framework for evaluating the effectiveness of MSW management systems. In this paper, detailed cost/benefit items due to waste problems are particularly clarified. The stakeholders of MSW management systems, including the decision-makers of the municipalities and the citizens, are expected to reconsider the waste problems in depth and thus take wise actions with the aid of the proposed CBA framework. Secondly, focusing on the financial cost, this study develops a generalized methodology to evaluate the financial cost-effectiveness of MSW management systems, simultaneously considering the treatment technological levels and policy effects. The impacts of the influencing factors on the annual total and average financial MSW operation and maintenance (O and M) costs are analyzed in the Taiwanese case study with a demonstrative short-term future projection of the financial costs under scenario analysis. The established methodology would contribute to the evaluation of the current policy measures and to the modification of the policy design for the municipalities.

Weng, Yu-Chi, E-mail: clyde.weng@gmail.com [Solid Waste Management Research Center, Okayama University, Okayama (Japan); Fujiwara, Takeshi [Solid Waste Management Research Center, Okayama University, Okayama (Japan)

2011-06-15T23:59:59.000Z

157

Eco-efficiency for greenhouse gas emissions mitigation of municipal solid waste management: A case study of Tianjin, China  

Science Conference Proceedings (OSTI)

The issue of municipal solid waste (MSW) management has been highlighted in China due to the continually increasing MSW volumes being generated and the limited capacity of waste treatment facilities. This article presents a quantitative eco-efficiency (E/E) analysis on MSW management in terms of greenhouse gas (GHG) mitigation. A methodology for E/E analysis has been proposed, with an emphasis on the consistent integration of life cycle assessment (LCA) and life cycle costing (LCC). The environmental and economic impacts derived from LCA and LCC have been normalized and defined as a quantitative E/E indicator. The proposed method was applied in a case study of Tianjin, China. The study assessed the current MSW management system, as well as a set of alternative scenarios, to investigate trade-offs between economy and GHG emissions mitigation. Additionally, contribution analysis was conducted on both LCA and LCC to identify key issues driving environmental and economic impacts. The results show that the current Tianjin's MSW management system emits the highest GHG and costs the least, whereas the situation reverses in the integrated scenario. The key issues identified by the contribution analysis show no linear relationship between the global warming impact and the cost impact in MSW management system. The landfill gas utilization scenario is indicated as a potential optimum scenario by the proposed E/E analysis, given the characteristics of MSW, technology levels, and chosen methodologies. The E/E analysis provides an attractive direction towards sustainable waste management, though some questions with respect to uncertainty need to be discussed further.

Zhao Wei, E-mail: zhaowei.tju@gmail.com [College of Civil Engineering and Architecture, Liaoning University of Technology, 121000 Jinzhou (China); Institute of Environmental Sciences (CML), Leiden University, P.O. Box 9518, 2300RA Leiden (Netherlands); Huppes, Gjalt, E-mail: huppes@cml.leidenuniv.nl [Institute of Environmental Sciences (CML), Leiden University, P.O. Box 9518, 2300RA Leiden (Netherlands); Voet, Ester van der, E-mail: Voet@cml.leidenuniv.nl [Institute of Environmental Sciences (CML), Leiden University, P.O. Box 9518, 2300RA Leiden (Netherlands)

2011-06-15T23:59:59.000Z

158

Combustion of municipal solid wastes with oil shale in a circulating fluidized bed. Second quarterly report ending March 31, 1995  

DOE Green Energy (OSTI)

The Project Description lists and describes six tasks, three of which are virtually complete, with three others underway. A summary of progress on each task follows. Task 1: Development of a Detailed Test Plan. This task is complete. Task 2: Preparation of Test Equipment. This task is complete. Two test units (a six-inch internal diameter and a fifteen-inch internal diameter unit) were prepared and used as described under Task 4. Task 3: Obtain test materials. The required amounts of oil shale and pelletized municipal solid waste have been obtained, tested, and found to be suitable. We have obtained an adequate quantity of a pelletized ``standard`` MSW from BEPR/BFI, Eden Prairie, MN. For test purposes, we synthesized the desired ``worst probable case`` of MSW by the addition of sulfur and chlorine to reach the sulfur and chlorine levels characteristic of such waste. Task 4: Execute Feasibility Demonstration Program. The fluidized bed tests associated with the program have been completed. Analysis of the results is continuing. Testing of the waste stream material generated from these runs will begin about 6 April to evaluate its possible use as cement for specific applications. Information on the technical feasibility of the invention as indicated by the fluid bed test program is included as Attachment A. The results demonstrate that the process is technically feasible. Task 5: Data Analysis. This task is beginning. Task 6: Project Management, Reporting, and Necessary Liaison Activities. Those portions of this task associated with work done on Tasks 1 through 4 have been completed. This task will continue throughout the period of the study. In summary, work is proceeding within budget. No serious problems in the next scheduled tasks are foreseen.

NONE

1995-04-01T23:59:59.000Z

159

Feasibility of geothermal heat use in the San Bernardino Municipal Wastewater Treatment Plant. Final report, September 1980-June 1981  

DOE Green Energy (OSTI)

A system was developed for utilizing nearby low temperature geothermal energy to heat two high-rate primary anaerobic digesters at the San Bernardino Wastewater Treatment Plant. The geothermal fluid would replace the methane currently burned to fuel the digesters. A summary of the work accomplished on the feasibility study is presented. The design and operation of the facility are examined and potentially viable applications selected for additional study. Results of these investigations and system descriptions and equipment specifications for utilizing geothermal energy in the selected processes are presented. The economic analyses conducted on the six engineering design cases are discussed. The environmental setting of the project and an analysis of the environmental impacts that will result from construction and operation of the geothermal heating system are discussed. A Resource Development Plan describes the steps that the San Bernardino Municipal Water Department could follow in order to utilize the resource. A preliminary well program and rough cost estimates for the production and injection wells also are included. The Water Department is provided with a program and schedule for implementing a geothermal system to serve the wastewater treatment plant. Regulatory, financial, and legal issues that will impact the project are presented in the Appendix. An outline of a Public Awareness Program is included.

Racine, W.C.; Larson, T.C.; Stewart, C.A.; Wessel, H.B.

1981-06-01T23:59:59.000Z

160

High energy bursts from a solid state laser operated in the heat capacity limited regime  

DOE Patents (OSTI)

Solid state laser technology is a very well developed field and numerous embodiments and modes of operation have been demonstrated. A more recent development has been the pumping of a solid state laser active medium with an array of diode lasers (diode pumping, for short). These diode pump packages have previously been developed to pump solid state lasers with good efficiency, but low average power. This invention is a method and the resulting apparatus for operating a solid state laser in the heat capacity mode. Instead of cooling the laser, the active medium will heat up until it reaches some maximum acceptable temperature. The waste heat is stored in the active medium itself.

Albrecht, G.; George, E.V.; Krupke, W. [and others

1994-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Risk assessment of the health liabilities from exposure to toxic metals found in the composted material of Air Force municipal solid waste. Master's thesis  

Science Conference Proceedings (OSTI)

This thesis assesses the risk of the health liabilities from exposure to toxic metals found in the composted material of Air Force municipal solid waste (MSW). The goal is to determine the probability that the composted MSW could be a health hazard if it were used as a soil amendment. The research limited the assessment of the exposure risk to heavy metals found in raw MSW and its resulting compost. The thesis uses reviews of present literature to examine the food and soil ingestion exposure pathways. These pathways are assessed using the heavy metal concentrations found in MSW compost and the soil-plant partition coefficients of vegetables grown in soil mixed with sewage sludge or soil irrigated with sewage sludge or soil irrigated with sewage sludge leachate. The recommendation resulting from this research is that the Air Force should not use MSW composting as part of its future solid waste management plan. This alternative to landfilling contains a chronic health risk that is greater than the Environmental Protection Agency's guideline. If the Air Force would use MSW composting in the future, it may endanger Air Force personnel and others who use the compost created from Air Force MSW. Risk assessment, Heavy metals, Recycling municipal solid waste, Pollution, Composting.

Merrymon, T.L.

1993-09-01T23:59:59.000Z

162

Reducing Mercury Emissions from Municipal Solid Waste Combustion (Results of Investigations and Testing at the Camden Resource Recovery Facility)  

E-Print Network (OSTI)

technologies for mercury control for flue gases of Municipal Waste Combustors (MWCs) not only ecological hydrochloric acid (HCl) and elemental mercury (Hg") under oxidizing conditions of the off-gases downstream to the decreasing gas temperature, the elemental mercury is able to react with other flue gas components. The main

Columbia University

163

Energy conservation: policy issues and end-use scenarios of savings potential. Part 2. Tradeoffs of municipal solid-waste-processing alternatives  

DOE Green Energy (OSTI)

The objective of this report is to assess the comparative performance and advantages of the various garbage-processing or disposal (landfill) techniques, and to address the issue of large-scale recycling of waste material. Five general methods are discussed: close-in landfill, remote landfill, refuse-derived solid fuel (RDSF), pyrolysis, and incineration. The major issue at this time concerning municipal solid waste disposal is whether to continue with landfill as the primary method or to use some combination of source separation, resource recovery, and energy generation. The constraints surrounding this issue are capital and labor costs, technical feasibility, environmental impacts--especially air pollution--marketability of the derived energy and recycled resources, and public cooperation. (MCW)

Codina, R.; Langlois, C.

1978-09-01T23:59:59.000Z

164

Application of spatial and non-spatial data analysis in determination of the factors that impact municipal solid waste generation rates in Turkey  

SciTech Connect

Highlights: Black-Right-Pointing-Pointer Spatial autocorrelation exists in municipal solid waste generation rates for different provinces in Turkey. Black-Right-Pointing-Pointer Traditional non-spatial regression models may not provide sufficient information for better solid waste management. Black-Right-Pointing-Pointer Unemployment rate is a global variable that significantly impacts the waste generation rates in Turkey. Black-Right-Pointing-Pointer Significances of global parameters may diminish at local scale for some provinces. Black-Right-Pointing-Pointer GWR model can be used to create clusters of cities for solid waste management. - Abstract: In studies focusing on the factors that impact solid waste generation habits and rates, the potential spatial dependency in solid waste generation data is not considered in relating the waste generation rates to its determinants. In this study, spatial dependency is taken into account in determination of the significant socio-economic and climatic factors that may be of importance for the municipal solid waste (MSW) generation rates in different provinces of Turkey. Simultaneous spatial autoregression (SAR) and geographically weighted regression (GWR) models are used for the spatial data analyses. Similar to ordinary least squares regression (OLSR), regression coefficients are global in SAR model. In other words, the effect of a given independent variable on a dependent variable is valid for the whole country. Unlike OLSR or SAR, GWR reveals the local impact of a given factor (or independent variable) on the waste generation rates of different provinces. Results show that provinces within closer neighborhoods have similar MSW generation rates. On the other hand, this spatial autocorrelation is not very high for the exploratory variables considered in the study. OLSR and SAR models have similar regression coefficients. GWR is useful to indicate the local determinants of MSW generation rates. GWR model can be utilized to plan waste management activities at local scale including waste minimization, collection, treatment, and disposal. At global scale, the MSW generation rates in Turkey are significantly related to unemployment rate and asphalt-paved roads ratio. Yet, significances of these variables may diminish at local scale for some provinces. At local scale, different factors may be important in affecting MSW generation rates.

Keser, Saniye [Department of Environmental Engineering, Middle East Technical University, 06800 Ankara (Turkey); Duzgun, Sebnem [Department of Mining Engineering, Middle East Technical University, 06800 Ankara (Turkey); Department of Geodetic and Geographic Information Technologies, Middle East Technical University, 06800 Ankara (Turkey); Aksoy, Aysegul, E-mail: aaksoy@metu.edu.tr [Department of Environmental Engineering, Middle East Technical University, 06800 Ankara (Turkey)

2012-03-15T23:59:59.000Z

165

Massachusetts Municipal Commercial Industrial Incentive Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Massachusetts Municipal Commercial Industrial Incentive Program Massachusetts Municipal Commercial Industrial Incentive Program Massachusetts Municipal Commercial Industrial Incentive Program < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Sealing Your Home Cooling Construction Design & Remodeling Manufacturing Other Windows, Doors, & Skylights Ventilation Appliances & Electronics Commercial Lighting Lighting Insulation Water Heating Maximum Rebate Varies depending on utility Program Info Start Date Varies Expiration Date Varies State Massachusetts Program Type Utility Rebate Program Rebate Amount Varies depending on utility Provider Massachusetts Municipal Wholesale Electric Company Certain municipal utilities in Massachusetts, in cooperation with

166

Reducing volatilization of heavy metals in phosphate-pretreated municipal solid waste incineration fly ash by forming pyromorphite-like minerals  

Science Conference Proceedings (OSTI)

This research investigated the feasibility of reducing volatilization of heavy metals (lead, zinc and cadmium) in municipal solid waste incineration (MSWI) fly ash by forming pyromorphite-like minerals via phosphate pre-treatment. To evaluate the evaporation characteristics of three heavy metals from phosphate-pretreated MSWI fly ash, volatilization tests have been performed by means of a dedicated apparatus in the 100-1000 deg. C range. The toxicity characteristic leaching procedure (TCLP) test and BCR sequential extraction procedure were applied to assess phosphate stabilization process. The results showed that the volatilization behavior in phosphate-pretreated MSWI fly ash could be reduced effectively. Pyromorphite-like minerals formed in phosphate-pretreated MSWI fly ash were mainly responsible for the volatilization reduction of heavy metals in MSWI fly ash at higher temperature, due to their chemical fixation and thermal stabilization for heavy metals. The stabilization effects were encouraging for the potential reuse of MSWI fly ash.

Sun Ying; Zheng Jianchang [School of Environmental and Chemical Engineering, Shanghai University, Shanghai 200444 (China); Zou Luquan [Shanghai Center of Solid Waste Disposal, Shanghai (China); Liu Qiang; Zhu Ping [School of Environmental and Chemical Engineering, Shanghai University, Shanghai 200444 (China); Qian Guangren, E-mail: grqian@mail.shu.edu.cn [School of Environmental and Chemical Engineering, Shanghai University, Shanghai 200444 (China)

2011-02-15T23:59:59.000Z

167

Thermodynamic estimation of minor element distribution between immiscible liquids in Fe-Cu-based metal phase generated in melting treatment of municipal solid wastes  

SciTech Connect

Graphical abstract: Display Omitted Highlights: Black-Right-Pointing-Pointer Two liquids separation of metal occurs in the melting of municipal solid waste. Black-Right-Pointing-Pointer The distribution of PGMs etc. between two liquid metal phases is studied. Black-Right-Pointing-Pointer Quite simple thermodynamic model is applied to predict the distribution ratio. Black-Right-Pointing-Pointer Au and Ag originated from WEEE are found to be concentrated into Cu-rich phase. - Abstract: Waste electrical and electronic equipment (WEEE) has become an important target in managing material cycles from the viewpoint of not only waste management and control of environmental pollution but also resource conservation. This study investigated the distribution tendency of trace elements in municipal solid waste (MSW) or incinerator ash, including valuable non-ferrous metals (Ni, Co, Cr, Mn, Mo, Ti, V, W, Zr), precious group metals (PGMs) originated from WEEE (Ag, Au, Pd, Pt), and others (Al, B, Pb, Si), between Fe-rich and Cu-rich metal phases by means of simple thermodynamic calculations. Most of the typical alloying elements for steel (Co, Cr, Mo, Nb, Ni, Si, Ti, V, and W) and Rh were preferentially distributed into the Fe-rich phase. PGMs, such as Au, Ag, and Pd, were enriched in the Cu-rich phase, whereas Pt was almost equally distributed into both phases. Since the primary metallurgical processing of Cu is followed by an electrolysis for refining, and since PGMs in crude copper have been industrially recovered from the resulting anode slime, our results indicated that Ag, Au, and Pd could be effectively recovered from MSW if the Cu-rich phase could be selectively collected.

Lu, X. [School of Metallurgical and Ecological Engineering, The University of Science and Technology Beijing, 30 Xueyuan Road, Haidian District, Beijing 100083 (China); Nakajima, K.; Sakanakura, H. [Research Center for Material Cycles and Waste Management, National Institute for Environmental Studies (NIES), 16-2 Onogawa, Tsukuba 305-8506 (Japan); Matsubae, K. [Graduate School of Engineering, Tohoku University, 6-6-11 Aza-Aoba, Aramaki, Sendai 980-8579 (Japan); Bai, H. [School of Metallurgical and Ecological Engineering, The University of Science and Technology Beijing, 30 Xueyuan Road, Haidian District, Beijing 100083 (China); Nagasaka, T., E-mail: t-nagasaka@m.tohoku.ac.jp [Graduate School of Engineering, Tohoku University, 6-6-11 Aza-Aoba, Aramaki, Sendai 980-8579 (Japan)

2012-06-15T23:59:59.000Z

168

High energy bursts from a solid state laser operated in the heat capacity limited regime  

DOE Patents (OSTI)

High energy bursts are produced from a solid state laser operated in a heat capacity limited regime. Instead of cooling the laser, the active medium is thermally well isolated. As a result, the active medium will heat up until it reaches some maximum acceptable temperature. The waste heat is stored in the active medium itself. Therefore, the amount of energy the laser can put out during operation is proportional to its mass, the heat capacity of the active medium, and the temperature difference over which it is being operated. The high energy burst capacity of a heat capacity operated solid state laser, together with the absence of a heavy, power consuming steady state cooling system for the active medium, will make a variety of applications possible. Alternately, cooling takes place during a separate sequence when the laser is not operating. Industrial applications include new material working processes.

Albrecht, Georg (Livermore, CA); George, E. Victor (Livermore, CA); Krupke, William F. (Pleasanton, CA); Sooy, Walter (Pleasanton, CA); Sutton, Steven B. (Manteca, CA)

1996-01-01T23:59:59.000Z

169

High energy bursts from a solid state laser operated in the heat capacity limited regime  

DOE Patents (OSTI)

High energy bursts are produced from a solid state laser operated in a heat capacity limited regime. Instead of cooling the laser, the active medium is thermally well isolated. As a result, the active medium will heat up until it reaches some maximum acceptable temperature. The waste heat is stored in the active medium itself. Therefore, the amount of energy the laser can put out during operation is proportional to its mass, the heat capacity of the active medium, and the temperature difference over which it is being operated. The high energy burst capacity of a heat capacity operated solid state laser, together with the absence of a heavy, power consuming steady state cooling system for the active medium, will make a variety of applications possible. Alternately, cooling takes place during a separate sequence when the laser is not operating. Industrial applications include new material working processes. 5 figs.

Albrecht, G.; George, E.V.; Krupke, W.F.; Sooy, W.; Sutton, S.B.

1996-06-11T23:59:59.000Z

170

Heat capacity of liquids: an approach from the solid phase  

E-Print Network (OSTI)

We calculate the energy and heat capacity of a liquid on the basis of its elastic properties and vibrational states. The experimental decrease of liquid heat capacity with temperature is attributed to the increasing loss of two transverse modes with frequency $\\omegacapacity is related to viscosity and is compared with the experimental data of mercury. We also calculate the vibrational energy of a quantum liquid, and show that transverse phonons can not be excited in the low-temperature limit. Finally, we discuss the implications of the proposed approach to liquids for the problem of glass transition.

Kostya Trachenko

2008-07-24T23:59:59.000Z

171

Solid Waste Management Act (Pennsylvania)  

Energy.gov (U.S. Department of Energy (DOE))

This Act provides for the planning and regulation of solid waste storage, collection, transportation, processing, treatment, and disposal. It requires that municipalities submit plans for municipal...

172

Municipal Solid Waste Combustion : Fuel Testing and Characterization : Task 1 Report, May 30, 1990-October 1, 1990.  

DOE Green Energy (OSTI)

The objective of this study is to screen and characterize potential biomass fuels from waste streams. This will be accomplished by determining the types of pollutants produced while burning selected municipal waste, i.e., commercial mixed waste paper residential (curbside) mixed waste paper, and refuse derived fuel. These materials will be fired alone and in combination with wood, equal parts by weight. The data from these experiments could be utilized to size pollution control equipment required to meet emission standards. This document provides detailed descriptions of the testing methods and evaluation procedures used in the combustion testing and characterization project. The fuel samples will be examined thoroughly from the raw form to the exhaust emissions produced during the combustion test of a densified sample.

Bushnell, Dwight J.; Canova, Joseph H.; Dadkhah-Nikoo, Abbas.

1990-10-01T23:59:59.000Z

173

International Best Practices for Pre-Processing and Co-Processing Municipal Solid Waste and Sewage Sludge in the Cement Industry  

E-Print Network (OSTI)

uniformity. Shredding of mixed waste to about 10 centimetersand untreated mixed municipal waste. GTZ/Holcim (2006) givesCEMBUREAU 2009). Mixed municipal waste must be pre-processed

Hasanbeigi, Ali

2013-01-01T23:59:59.000Z

174

Process for oil shale retorting using gravity-driven solids flow and solid-solid heat exchange  

DOE Patents (OSTI)

A cascading bed retorting process and apparatus in which cold raw crushed shale enters at the middle of a retort column into a mixer stage where it is rapidly mixed with hot recycled shale and thereby heated to pyrolysis temperature. The heated mixture then passes through a pyrolyzer stage where it resides for a sufficient time for complete pyrolysis to occur. The spent shale from the pyrolyzer is recirculated through a burner stage where the residual char is burned to heat the shale which then enters the mixer stage.

Lewis, Arthur E. (Los Altos, CA); Braun, Robert L. (Livermore, CA); Mallon, Richard G. (Livermore, CA); Walton, Otis R. (Livermore, CA)

1986-01-01T23:59:59.000Z

175

Process for oil shale retorting using gravity-driven solids flow and solid-solid heat exchange  

DOE Patents (OSTI)

A cascading bed retorting process and apparatus are disclosed in which cold raw crushed shale enters at the middle of a retort column into a mixer stage where it is rapidly mixed with hot recycled shale and thereby heated to pyrolysis temperature. The heated mixture then passes through a pyrolyzer stage where it resides for a sufficient time for complete pyrolysis to occur. The spent shale from the pyrolyzer is recirculated through a burner stage where the residual char is burned to heat the shale which then enters the mixer stage.

Lewis, A.E.; Braun, R.L.; Mallon, R.G.; Walton, O.R.

1983-09-21T23:59:59.000Z

176

Reconsidering Municipal Solid Waste as a Renewable Energy Feedstock For many years, opposition to the use of municipal solid waste (MSW) as an energy resource has been nearly universal among  

E-Print Network (OSTI)

used in that year,2 depending on conversion efficiency.3 Alternatively, Fulcrum BioEnergy estimates reaction.22 · Gasification -- MSW is heated in a chamber with a small amount of oxygen present for conversion into renewable fuels or other biobased products.23 Gasification is economically viable at a small

Columbia University

177

Parameters affecting the stability of the digestate from a two-stage anaerobic process treating the organic fraction of municipal solid waste  

SciTech Connect

This paper focused on the factors affecting the respiration rate of the digestate taken from a continuous anaerobic two-stage process treating the organic fraction of municipal solid waste (OFMSW). The process involved a hydrolytic reactor (HR) that produced a leachate fed to a submerged anaerobic membrane bioreactor (SAMBR). It was found that a volatile solids (VS) removal in the range 40-75% and an operating temperature in the HR between 21 and 35 {sup o}C resulted in digestates with similar respiration rates, with all digestates requiring 17 days of aeration before satisfying the British Standard Institution stability threshold of 16 mg CO{sub 2} g VS{sup -1} day{sup -1}. Sanitization of the digestate at 65 {sup o}C for 7 days allowed a mature digestate to be obtained. At 4 g VS L{sup -1} d{sup -1} and Solid Retention Times (SRT) greater than 70 days, all the digestates emitted CO{sub 2} at a rate lower than 25 mg CO{sub 2} g VS{sup -1} d{sup -1} after 3 days of aeration, while at SRT lower than 20 days all the digestates displayed a respiration rate greater than 25 mg CO{sub 2} g VS{sup -1} d{sup -1}. The compliance criteria for Class I digestate set by the European Commission (EC) and British Standard Institution (BSI) could not be met because of nickel and chromium contamination, which was probably due to attrition of the stainless steel stirrer in the HR.

Trzcinski, Antoine P., E-mail: a.trzcinski05@ic.ac.uk [Department of Chemical Engineering, Imperial College of Science and Technology and Medicine, Prince Consort Road, London SW7 2AZ (United Kingdom); Stuckey, David C., E-mail: d.stuckey@ic.ac.uk [Department of Chemical Engineering, Imperial College of Science and Technology and Medicine, Prince Consort Road, London SW7 2AZ (United Kingdom)

2011-07-15T23:59:59.000Z

178

Reading Municipal Light Department - Residential ENERGY STAR...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential ENERGY STAR Appliance Rebate Program Reading Municipal Light Department - Residential ENERGY STAR Appliance Rebate Program Eligibility Residential Savings For Heating &...

179

Visualization of heat transport using dimensionless heatfunction for natural convection and conduction in an enclosure with thick solid ceiling  

Science Conference Proceedings (OSTI)

A conjugate conduction-(natural)convection problem is numerically studied in order to present the application of dimensionless heatfunction for entire computational domain including solid and fluid regions in an enclosure with thick solid ceiling. The ... Keywords: Conjugate heat transfer, Dimensionless heatfunction, Heat transport, Heatline, Natural convection

Moghtada Mobedi; Hakan F. Oztop

2008-11-01T23:59:59.000Z

180

Thermal conversion of municipal solid waste via hydrothermal carbonization: Comparison of carbonization products to products from current waste management techniques  

Science Conference Proceedings (OSTI)

Highlights: Black-Right-Pointing-Pointer Hydrothermal carbonization (HTC) is a novel thermal conversion process. Black-Right-Pointing-Pointer HTC converts wastes into value-added resources. Black-Right-Pointing-Pointer Carbonization integrates majority of carbon into solid-phase. Black-Right-Pointing-Pointer Carbonization results in a hydrochar with high energy density. Black-Right-Pointing-Pointer Using hydrochar as an energy source may be beneficial. - Abstract: Hydrothermal carbonization (HTC) is a novel thermal conversion process that may be a viable means for managing solid waste streams while minimizing greenhouse gas production and producing residual material with intrinsic value. HTC is a wet, relatively low temperature (180-350 Degree-Sign C) thermal conversion process that has been shown to convert biomass to a carbonaceous residue referred to as hydrochar. Results from batch experiments indicate HTC of representative waste materials is feasible, and results in the majority of carbon (45-75% of the initially present carbon) remaining within the hydrochar. Gas production during the batch experiments suggests that longer reaction periods may be desirable to maximize the production of energy-favorable products. If using the hydrochar for applications in which the carbon will remain stored, results suggest that the gaseous products from HTC result in fewer g CO{sub 2}-equivalent emissions than the gases associated with landfilling, composting, and incineration. When considering the use of hydrochar as a solid fuel, more energy can be derived from the hydrochar than from the gases resulting from waste degradation during landfilling and anaerobic digestion, and from incineration of food waste. Carbon emissions resulting from the use of the hydrochar as a fuel source are smaller than those associated with incineration, suggesting HTC may serve as an environmentally beneficial alternative to incineration. The type and extent of environmental benefits derived from HTC will be dependent on hydrochar use/the purpose for HTC (e.g., energy generation or carbon storage).

Lu Xiaowei; Jordan, Beth [Department of Civil and Environmental Engineering, University of South Carolina, 300 Main Street, Columbia, SC 29208 (United States); Berge, Nicole D., E-mail: berge@cec.sc.edu [Department of Civil and Environmental Engineering, University of South Carolina, 300 Main Street, Columbia, SC 29208 (United States)

2012-07-15T23:59:59.000Z

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Mansfield Municipal Electric Department - Residential Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Mansfield Municipal Electric Department - Residential Energy Mansfield Municipal Electric Department - Residential Energy Efficiency Rebate Program Mansfield Municipal Electric Department - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Maximum Rebate $100 limit per customer account for appliances purchased in the same calendar year. Program Info Expiration Date 12/31/2014 State Massachusetts Program Type Utility Rebate Program Rebate Amount Central AC: $100 Refrigerators: $100 Clothes Washing Machines: $100 Dishwashers: $75 Dehumidifiers: $50 Window Air Conditioners: $50 Provider Mansfield Municipal Electric Department Mansfield Municipal Electric Department encourages energy efficiency

182

Oklahoma Municipal Power Authority - Commercial and Industrial Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Oklahoma Municipal Power Authority - Commercial and Industrial Oklahoma Municipal Power Authority - Commercial and Industrial Energy Efficiency Program Oklahoma Municipal Power Authority - Commercial and Industrial Energy Efficiency Program < Back Eligibility Commercial Industrial Local Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Heating Appliances & Electronics Commercial Lighting Lighting Manufacturing Maximum Rebate $100,000 Program Info Funding Source American Recovery and Reinvestment Act of 2009 State Oklahoma Program Type Utility Rebate Program Rebate Amount Matching Funds up to $100,000 Provider Oklahoma Municipal Power Authority The Oklahoma Municipal Power Authority (OMPA) offers the Demand and Energy Efficiency Program (DEEP) to eligible commercial, industrial, and municipal

183

Municipal Solid Waste (MSW) to Liquid Fuels Synthesis, Volume 2: A Techno-economic Evaluation of the Production of Mixed Alcohols  

DOE Green Energy (OSTI)

Biomass is a renewable energy resource that can be converted into liquid fuel suitable for transportation applications and thus help meet the Energy Independence and Security Act renewable energy goals (U.S. Congress 2007). However, biomass is not always available in sufficient quantity at a price compatible with fuels production. Municipal solid waste (MSW) on the other hand is readily available in large quantities in some communities and is considered a partially renewable feedstock. Furthermore, MSW may be available for little or no cost. This report provides a techno-economic analysis of the production of mixed alcohols from MSW and compares it to the costs for a wood based plant. In this analysis, MSW is processed into refuse derived fuel (RDF) and then gasified in a plant co-located with a landfill. The resulting syngas is then catalytically converted to mixed alcohols. At a scale of 2000 metric tons per day of RDF, and using current technology, the minimum ethanol selling price at a 10% rate of return is approximately $1.85/gallon ethanol (early 2008 $). However, favorable economics are dependent upon the toxicity characteristics of the waste streams and that a market exists for the by-product scrap metal recovered from the RDF process.

Jones, Susanne B.; Zhu, Yunhua; Valkenburg, Corinne

2009-05-01T23:59:59.000Z

184

Assessment of landfill reclamation and the effects of age on the combustion of recovered municipal solid waste  

DOE Green Energy (OSTI)

This report summarized the Lancaster county Solid Waste Management Authorities`s (LCSWMA)landfill reclamation activities, ongoing since 1991. All aspects have been analyzed from the manpower and equipment requirements at the landfill to the operational impacts felt at the LCSWMA Resource Recovery Facility (RRF) where the material is delivered for processing. Characteristics of the reclaimed refuse and soil recovered from trommeling operations are discussed as are results of air monitoring performed at the landfill excavation site and the RRF. The report also discusses the energy value of the reclaimed material and compares this value with those obtained for significantly older reclaimed waste streams. The effects of waste age on the air emissions and ash residue quality at the RRF are also provided. The report concludes by summarizing the project benefits and provides recommendations for other landfill reclamation operations and areas requiring further research.

Forster, G.A. [Lancaster Environmental Foundation, PA (United States)] [Lancaster Environmental Foundation, PA (United States)

1995-01-01T23:59:59.000Z

185

Numerical Simulation of Thermal-Solid Coupling to Coal-Rock during the Process of Heat Injection Mine for CBM  

Science Conference Proceedings (OSTI)

For gaining effective influence radius of heat injection mine for CBM (Coal Bed Methane) and influence rules of permeability under the condition of temperature and effective stress, heat transfer and elastic mechanics theory combined, hooker law of thermal ... Keywords: heat injection, thermal-solid coupling, numerical simulation, effective influence radius, permeability

Xin Le Yang; Yong Li Zhang

2010-12-01T23:59:59.000Z

186

High temperature solid lubricant materials for heavy duty and advanced heat engines  

DOE Green Energy (OSTI)

Advanced engine designs incorporate higher mechanical and thermal loading to achieve efficiency improvements. This approach often leads to higher operating temperatures of critical sliding elements (e.g. piston ring/cylinder wall contacts and valve guides) which compromise the use of conventional and even advanced synthetic liquid lubricants. For these applications solid lubricants must be considered. Several novel solid lubricant composites and coatings designated PS/PM200 have been employed to dry and marginally oil lubricated contacts in advanced heat engines. These applications include cylinder kits of heavy duty diesels, and high temperature sterling engines, sidewall seals of rotary engines and various exhaust valve and exhaust component applications. The following paper describes the tribological and thermophysical properties of these tribomaterials and reviews the results of applying them to engine applications. Other potential tribological materials and applications are also discussed with particular emphasis to heavy duty and advanced heat engines.

DellaCorte, C.; Wood, J.C.

1994-10-01T23:59:59.000Z

187

Mercury emissions from municipal solid waste combustors. An assessment of the current situation in the United States and forecast of future emissions  

Science Conference Proceedings (OSTI)

This report examines emissions of mercury (Hg) from municipal solid waste (MSW) combustion in the United States (US). It is projected that total annual nationwide MSW combustor emissions of mercury could decrease from about 97 tonnes (1989 baseline uncontrolled emissions) to less than about 4 tonnes in the year 2000. This represents approximately a 95 percent reduction in the amount of mercury emitted from combusted MSW compared to the 1989 mercury emissions baseline. The likelihood that routinely achievable mercury emissions removal efficiencies of about 80 percent or more can be assured; it is estimated that MSW combustors in the US could prove to be a comparatively minor source of mercury emissions after about 1995. This forecast assumes that diligent measures to control mercury emissions, such as via use of supplemental control technologies (e.g., carbon adsorption), are generally employed at that time. However, no present consensus was found that such emissions control measures can be implemented industry-wide in the US within this time frame. Although the availability of technology is apparently not a limiting factor, practical implementation of necessary control technology may be limited by administrative constraints and other considerations (e.g., planning, budgeting, regulatory compliance requirements, etc.). These projections assume that: (a) about 80 percent mercury emissions reduction control efficiency is achieved with air pollution control equipment likely to be employed by that time; (b) most cylinder-shaped mercury-zinc (CSMZ) batteries used in hospital applications can be prevented from being disposed into the MSW stream or are replaced with alternative batteries that do not contain mercury; and (c) either the amount of mercury used in fluorescent lamps is decreased to an industry-wide average of about 27 milligrams of mercury per lamp or extensive diversion from the MSW stream of fluorescent lamps that contain mercury is accomplished.

Not Available

1993-05-01T23:59:59.000Z

188

Feasibility of geothermal heat use in the San Bernardino Municipal Wastewater Treatment Plant. Final report, September 1980-June 1981  

DOE Green Energy (OSTI)

The results of the feasibility study for utilizing low temperature geothermal heat in the City of San Bernardino Wastewater Treatment Plant are summarized. The study is presented in terms of preliminary engineering design, economic analysis, institutional issues, environmental impacts, resource development, and system implementation.

Racine, W.C.; Larson, T.C.; Stewart, C.A.; Wessel, H.B.

1981-06-01T23:59:59.000Z

189

River Falls Municipal Utilities - Renewable Energy Finance Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

River Falls Municipal Utilities - Renewable Energy Finance Program River Falls Municipal Utilities - Renewable Energy Finance Program River Falls Municipal Utilities - Renewable Energy Finance Program < Back Eligibility Residential Savings Category Other Buying & Making Electricity Solar Heating & Cooling Commercial Heating & Cooling Heating Water Heating Wind Program Info State Wisconsin Program Type PACE Financing Provider River Falls Municipal Utilities River Falls Municipal Utilities (RFMU) offers loans of $2,500 - $50,000 to its residential customers for the installation of photovoltaic (PV), solar thermal, geothermal, wind electric systems. The program will also support the installation of energy efficiency measures in connection with a qualifying renewable energy project, provided that the renewable energy

190

Municipal Energy Reduction Fund | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Municipal Energy Reduction Fund Municipal Energy Reduction Fund Municipal Energy Reduction Fund < Back Eligibility Local Government Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Sealing Your Home Cooling Construction Design & Remodeling Manufacturing Other Windows, Doors, & Skylights Ventilation Heat Pumps Appliances & Electronics Commercial Lighting Lighting Insulation Buying & Making Electricity Energy Sources Maximum Rebate $400,000 Program Info Start Date 3/17/2010 State New Hampshire Program Type State Loan Program Rebate Amount $5,000 to $400,000 Provider New Hampshire Community Development Finance Authority In March 2010, the New Hampshire Community Development Finance Authority (CDFA) launched a revolving loan program to encourage the state's

191

List of Passive Solar Space Heat Incentives | Open Energy Information  

Open Energy Info (EERE)

Space Heat Incentives Space Heat Incentives Jump to: navigation, search The following contains the list of 278 Passive Solar Space Heat Incentives. CSV (rows 1 - 278) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Alternative Energy and Energy Conservation Patent Exemption (Corporate) (Massachusetts) Industry Recruitment/Support Massachusetts Commercial Biomass Fuel Cells Geothermal Electric Ground Source Heat Pumps Hydroelectric energy Municipal Solid Waste Passive Solar Space Heat Photovoltaics Solar Space Heat Solar Thermal Electric Solar Thermal Process Heat Solar Water Heat Wind energy Yes Alternative Energy and Energy Conservation Patent Exemption (Personal) (Massachusetts) Industry Recruitment/Support Massachusetts General Public/Consumer Biomass

192

Guide to Clean Development Mechanism Projects Related to Municipal...  

Open Energy Info (EERE)

Name A Guide to Clean Development Mechanism Projects Related to Municipal Solid Waste Management AgencyCompany Organization United Nations Economic and Social Commission for...

193

Heat removal from high temperature tubular solid oxide fuel cells utilizing product gas from coal gasifiers.  

DOE Green Energy (OSTI)

In this work we describe the results of a computer study used to investigate the practicality of several heat exchanger configurations that could be used to extract heat from tubular solid oxide fuel cells (SOFCs) . Two SOFC feed gas compositions were used in this study. They represent product gases from two different coal gasifier designs from the Zero Emission Coal study at Los Alamos National Laboratory . Both plant designs rely on the efficient use of the heat produced by the SOFCs . Both feed streams are relatively rich in hydrogen with a very small hydrocarbon content . One feed stream has a significant carbon monoxide content with a bit less hydrogen . Since neither stream has a significant hydrocarbon content, the common use of the endothermic reforming reaction to reduce the process heat is not possible for these feed streams . The process, the method, the computer code, and the results are presented as well as a discussion of the pros and cons of each configuration for each process .

Parkinson, W. J. (William Jerry),

2003-01-01T23:59:59.000Z

194

Tree-Shaped Fluid Flow and Heat Storage in a Conducting Solid  

Science Conference Proceedings (OSTI)

This paper documents the time-dependent thermal interaction between a fluid stream configured as a plane tree of varying complexity embedded in a conducting solid with finite volume and insulated boundaries. The time scales of the convection-conduction phenomenon are identified. Two-dimensional and three-dimensional configurations are simulated numerically. The number of length scales of the tree architecture varies from one to four. The results show that the heat transfer density increases, and the time of approach to equilibrium decreases as the complexity of the tree designs increases. These results are then formulated in the classical notation of energy storage by sensible heating, which shows that the effective number of heat transfer units increases as the complexity of the tree design increases. The complexity of heat transfer designs in many applications is constrained by first cost and operating cost considerations. This work provides a fundamental basis for objective evaluation of cost and performance tradeoffs in thermal design of energy systems with complexity as an unconstrained parameter that can be actively varied over a broad range to determine the optimum system design.

Combelles, L.; Lorente, S.; Anderson, R.; Bejan, A.

2012-01-01T23:59:59.000Z

195

3D CFD ELECTROCHEMICAL AND HEAT TRANSFER MODEL OF AN INTERNALLY MANIFOLDED SOLID OXIDE ELECTROLYSIS CELL  

DOE Green Energy (OSTI)

A three-dimensional computational fluid dynamics (CFD) electrochemical model has been created to model high-temperature electrolysis cell performance and steam electrolysis in an internally manifolded planar solid oxide electrolysis cell (SOEC) stack. This design is being evaluated at the Idaho National Laboratory for hydrogen production from nuclear power and process heat. Mass, momentum, energy, and species conservation and transport are provided via the core features of the commercial CFD code FLUENT. A solid-oxide fuel cell (SOFC) model adds the electrochemical reactions and loss mechanisms and computation of the electric field throughout the cell. The FLUENT SOFC user-defined subroutine was modified for this work to allow for operation in the SOEC mode. Model results provide detailed profiles of temperature, operating potential, steam-electrode gas composition, oxygen-electrode gas composition, current density and hydrogen production over a range of stack operating conditions. Single-cell and five-cell results will be presented. Flow distribution through both models is discussed. Flow enters from the bottom, distributes through the inlet plenum, flows across the cells, gathers in the outlet plenum and flows downward making an upside-down ''U'' shaped flow pattern. Flow and concentration variations exist downstream of the inlet holes. Predicted mean outlet hydrogen and steam concentrations vary linearly with current density, as expected. Effects of variations in operating temperature, gas flow rate, oxygen-electrode and steam-electrode current density, and contact resistance from the base case are presented. Contour plots of local electrolyte temperature, current density, and Nernst potential indicate the effects of heat transfer, reaction cooling/heating, and change in local gas composition. Results are discussed for using this design in the electrolysis mode. Discussion of thermal neutral voltage, enthalpy of reaction, hydrogen production, cell thermal efficiency, cell electrical efficiency, and Gibbs free energy are discussed and reported herein.

Grant L. Hawkes; James E. O'Brien; Greg Tao

2011-11-01T23:59:59.000Z

196

Effects of Time, Heat, and Oxygen on K Basin Sludge Agglomeration, Strength, and Solids Volume  

SciTech Connect

Sludge disposition will be managed in two phases under the K Basin Sludge Treatment Project. The first phase is to retrieve the sludge that currently resides in engineered containers in the K West (KW) Basin pool at ~10 to 18°C. The second phase is to retrieve the sludge from interim storage in the sludge transport and storage containers (STSCs) and treat and package it in preparation for eventual shipment to the Waste Isolation Pilot Plant. The work described in this report was conducted to gain insight into how sludge may change during long-term containerized storage in the STSCs. To accelerate potential physical and chemical changes, the tests were performed at temperatures and oxygen partial pressures significantly greater than those expected in the T Plant canyon cells where the STSCs will be stored. Tests were conducted to determine the effects of 50°C oxygenated water exposure on settled quiescent uraninite (UO2) slurry and a full simulant of KW containerized sludge to determine the effects of oxygen and heat on the composition and mechanical properties of sludge. Shear-strength measurements by vane rheometry also were conducted for UO2 slurry, mixtures of UO2 and metaschoepite (UO3•2H2O), and for simulated KW containerized sludge. The results from these tests and related previous tests are compared to determine whether the settled solids in the K Basin sludge materials change in volume because of oxidation of UO2 by dissolved atmospheric oxygen to form metaschoepite. The test results also are compared to determine if heating or other factors alter sludge volumes and to determine the effects of sludge composition and settling times on sludge shear strength. It has been estimated that the sludge volume will increase with time because of a uranium metal ? uraninite ? metaschoepite oxidation sequence. This increase could increase the number of containers required for storage and increase overall costs of sludge management activities. However, the volume might decrease because of decreases in the water-volume fraction caused by sludge solid reactions, compaction, or intergrowth and recrystallization of metaschoepite. In that case, fewer STSCs may be needed, but the shear strength would increase, and this could challenge recovery by water jet erosion and require more aggressive retrieval methods. Overall, the tests described herein indicate that the settled solids volume remains the same or decreases with time. The only case for which the sludge solids volumes increase with time is for the expansion factor attendant upon the anoxic corrosion of uranium metal to produce UO2 and subsequent reaction with oxygen to form equimolar UO2.25 and UO3•2H2O.

Delegard, Calvin H.; Sinkov, Sergey I.; Schmidt, Andrew J.; Daniel, Richard C.; Burns, Carolyn A.

2011-01-04T23:59:59.000Z

197

International Best Practices for Pre-Processing and Co-Processing Municipal Solid Waste and Sewage Sludge in the Cement Industry  

E-Print Network (OSTI)

engineering.de/116/) Co-firing of MSW and sewage sludge indevice for solid waste fuel co-firing Solid waste fuels areand HF produced during firing. ? CO is largely unaffected. ?

Hasanbeigi, Ali

2013-01-01T23:59:59.000Z

198

Marshall Municipal Utilities - Commercial Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Marshall Municipal Utilities - Commercial Energy Efficiency Rebate Marshall Municipal Utilities - Commercial Energy Efficiency Rebate Program Marshall Municipal Utilities - Commercial Energy Efficiency Rebate Program < Back Eligibility Commercial Fed. Government Industrial Local Government Nonprofit State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Manufacturing Other Appliances & Electronics Construction Heating Heat Pumps Commercial Lighting Lighting Water Heating Maximum Rebate Custom Measures: 75% of the incremental cost of the measure Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: Varies by fixture type, wattage and application Central A/C: $100/ton Air-Source Heat Pumps: $150/ton Geothermal Heat Pumps: $200/ton Commercial Refrigeration: See Program Website

199

Northern Municipal Power Agency - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Northern Municipal Power Agency - Residential Energy Efficiency Northern Municipal Power Agency - Residential Energy Efficiency Rebate Program (Minnesota) Northern Municipal Power Agency - Residential Energy Efficiency Rebate Program (Minnesota) < Back Eligibility Residential Savings Category Appliances & Electronics Heating & Cooling Commercial Heating & Cooling Heating Heat Pumps Commercial Lighting Lighting Water Heating Maximum Rebate $10,000 per customer per year Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Home Energy Assessment: discounted price Compact Fluorescent Lights: $2/light bulb LED Screw-In: $7/bulb LED Recessed Downlights: $15 - $25/install Clothes Washers: $50 Water Heaters: $150 Programmable Thermostat: $25 Supplemental Heating Source for Air-Source Heat Pump: $500

200

Biogas From Municipal WWTPs: Fuel Cells Viewed as a Value Proposition  

NLE Websites -- All DOE Office Websites (Extended Search)

From Municipal WWTPs From Municipal WWTPs Fuel Cells Viewed as a Value Proposition Biogas and Fuel Cells Workshop National Renewable Energy Laboratory Golden, Colorado June 12, 2012 WWTP Anaerobic Digestion * Common method of processing sludge to reduce volume of solids & volatile content * Reduces sludge disposal cost & increases outlets for disposal * Since motivation is disposal rather than digester gas (DG) production, the DG is available at no cost * This is unlike many other organic waste digestion facilities, where the energy project must bear cost of the digester(s) WWTP Anaerobic Digestion * WWTP anaerobic digesters require heat * Typically a portion of the DG is used to produce steam or hot water to provide the heat * The heat required varies seasonally,

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Army Solid State Laser Program: Design, Operation, and Mission Analysis for a Heat-Capacity Laser  

DOE Green Energy (OSTI)

Solid-state lasers have held great promise for the generation of high-average-power, high-quality output beams for a number of decades. However, the inherent difficulty of scaling the active solid-state gain media while continuing to provide efficient cooling has limited demonstrated powers to <5kW. Even at the maximum demonstrated average powers, the output is most often delivered as continuous wave (CW) or as small energy pulses at high pulse repetition frequency (PRF) and the beam divergence is typically >10X the diffraction limit. Challenges posed by optical distortions and depolarization arising from internal temperature gradients in the gain medium of a continuously cooled system are only increased for laser designs that would attempt to deliver the high average power in the form of high energy pulses (>25J) from a single coherent optical aperture. Although demonstrated phase-locking of multiple laser apertures may hold significant promise for the future scaling of solid-state laser systems,1 the continuing need for additional technical development and innovation coupled with the anticipated complexity of these systems effectively limits this approach for near-term multi-kW laser operation outside of a laboratory setting. We have developed and demonstrated a new operational mode for solid-state laser systems in which the cooling of the gain medium is separated in time from the lasing cycle. In ''heat-capacity'' operation, no cooling takes place during lasing. The gain medium is pumped very uniformly and the waste heat from the excitation process is stored in the solid-state gain medium. By depositing the heat on time scales that are short compared to thermal diffusion across the optical aperture, very high average power operation is possible while maintaining low optical distortions. After a lasing cycle, aggressive cooling can then take place in the absence of lasing, limited only by the fracture limit of the solid-state medium. This mode of operation is ideally suited for applications that require 1-30s engagements at very high average power. If necessary, multiple laser apertures can provide continuous operation. Land Combat mission analysis of a stressing air defense scenario including a dense attack of rockets, mortars, and artillery has indicated that multiple HEL weapon systems, based on the solid state, heat capacity laser concept, can provide significantly improved protection of high value battlefield assets. We will present EADSIM results for two government-supplied scenarios, one with temporally high threat density over a fairly large defended area, and one with fewer threats concentrating on a single defended asset. Implications for weapon system requirements will be presented. In order to demonstrate the operation of a high average power heat-capacity laser system, we have developed a flashlamp-pumped Nd:glass laser with output energies in the range of 500-1000J/pulse in a 10 x 10cm{sup 2} beam. With a repetition frequency of 20Hz, an average power of 13kW has been demonstrated for operational periods of up to 10s using a stable optical resonator (see enclosed figure). Using an M=1.4 unstable resonator, a beam divergence of 5X diffraction-limited has been measured with no active wavefront correction. An adaptively corrected unstable resonator that incorporates an intracavity deformable mirror controlled by feedback from an external wavefront sensor will provide <2X diffraction-limited output integrated over an entire 10s run at an average power of 10kW. A very similar laser architecture in which the Nd:glass is replaced by Nd:GGG and the flashlamps are replaced by large diode-laser arrays will enable the scaling of the output average power from the demonstrated 10kW to 100kW (500J/pulse at 200Hz). Risk reduction experiments for diode-pumped Nd:GGG, the fabrication of large Nd:GGG amplifier slabs, as well as the progress toward a sub-scale amplifier testbed pumped by diode arrays with total of 1MW peak power will also be presented.

Dane, C B; Flath, L; Rotter, M; Fochs, S; Brase, J; Bretney, K

2001-05-18T23:59:59.000Z

202

New York City - Green Building Requirements for Municipal Buildings |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Green Building Requirements for Municipal Buildings Green Building Requirements for Municipal Buildings New York City - Green Building Requirements for Municipal Buildings < Back Eligibility Local Government Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Home Weatherization Construction Commercial Weatherization Design & Remodeling Appliances & Electronics Commercial Lighting Lighting Bioenergy Solar Windows, Doors, & Skylights Buying & Making Electricity Water Water Heating Wind Program Info State New York Program Type Energy Standards for Public Buildings Provider Mayor's Office of Operations In 2005 New York City passed a law (Local Law No. 86) making a variety of green building and energy efficiency requirements for municipal buildings and other projects funded with money from the city treasury. The building

203

Reading Municipal Light Department - Business Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Reading Municipal Light Department - Business Energy Efficiency Reading Municipal Light Department - Business Energy Efficiency Rebate Program Reading Municipal Light Department - Business Energy Efficiency Rebate Program < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Heat Pumps Manufacturing Appliances & Electronics Buying & Making Electricity Energy Sources Solar Wind Maximum Rebate $50,000 Program Info Expiration Date 04/30/2013 State Massachusetts Program Type Utility Rebate Program Rebate Amount Up to $50,000 Provider Incentive Programs Reading Municipal Light Department (RMLD) offers energy efficiency incentives to eligible commercial and industrial customers. Rebates of up to $50,000 are available to customers who wish to reduce energy consumption

204

Alameda Municipal Power - Residential Energy Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alameda Municipal Power - Residential Energy Efficiency Program Alameda Municipal Power - Residential Energy Efficiency Program Alameda Municipal Power - Residential Energy Efficiency Program < Back Eligibility Low-Income Residential Multi-Family Residential Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Construction Commercial Heating & Cooling Design & Remodeling Program Info State California Program Type Utility Grant Program Rebate Amount Refrigerator Replacement: Up to $100 Second Refrigerator Pickup: $35 CFLs: 3 free replacement bulbs Motors: $0.18/per kWh saved Lighting: $0.20/per kWh saved HVAC: $0.22/per kWh saved Refrigeration: $0.22/per kWh saved Provider Alameda Municipal Power Alameda Municipal Power (AMP) has multiple program in place to help

205

Solid State Joining of High Temperature Alloy Tubes for USC and Heat-Exchanger Systems  

Science Conference Proceedings (OSTI)

The principal objective of this project was to develop materials enabling joining technologies for use in forward looking heat-exchanger fabrication in Brayton cycle HIPPS, IGCC, FutureGen concepts capable of operating at temperatures in excess of 1000{degree}C as well as conventional technology upgrades via Ultra Super-Critical (USC) Rankine-cycle boilers capable of operating at 760{degree}C (1400F)/38.5MPa (5500psi) steam, while still using coal as the principal fossil fuel. The underlying mission in Rankine, Brayton or Brayton-Rankine, or IGCC combined cycle heat engine is a steady quest to improving operating efficiency while mitigating global environmental concerns. There has been a progressive move to higher overall cycle efficiencies, and in the case of fossil fuels this has accelerated recently in part because of concerns about greenhouse gas emissions, notably CO{sub 2}. For a heat engine, the overall efficiency is closely related to the difference between the highest temperature in the cycle and the lowest temperature. In most cases, efficiency gains are prompted by an increase in the high temperature, and this in turn has led to increasing demands on the materials of construction used in the high temperature end of the systems. Our migration to new advanced Ni-base and Oxide Dispersion Strengthened (ODS) alloys poses significant fabrication challenges, as these materials are not readily weldable or the weld performs poorly in the high temperature creep regime. Thus the joining challenge is two-fold to a) devise appropriate joining methodologies for similar/dissimilar Ni-base and ODS alloys while b) preserving the near baseline creep performance in the welded region. Our program focus is on solid state joining of similar and dissimilar metals/alloys for heat exchanger components currently under consideration for the USC, HIPPS and IGCC power systems. The emphasis is to manipulate the joining methods and variables available to optimize joint creep performance compared to the base material creep performance. Similar and dissimilar butt joints were fabricated of MA956, IN740 alloys and using inertia welding techniques. We evaluated joining process details and heat treatments and its overall effect on creep response. Fixed and incrementally accelerated temperature creep tests were performed for similar and dissimilar joints and such incremental creep life data is compiled and reported. Long term MA956-MA556 joint tests indicate a firm 2Ksi creep stress threshold performance at 850{degree}C with a maximum exposure of over 9725 hours recorded in the current program. A Larsen Miller Parameter (LMP) of 48.50 for a 2Ksi test at 850{degree}C was further corroborated with tests at 2Ksi stress at 900{degree}C yielding a LMP=48.80. Despite this threshold the joints exhibit immense temperature sensitivity and fail promptly when test temperature raised above 900{degree}C. In comparison the performance of dissimilar joints was inferior, perhaps dictated by the creep characteristics of the mating nickel-base alloys. We describe a parametric window of joint development, and post weld heat treatment (PWHT) in dissimilar joints with solid solution (IN601, IN617) and precipitate strengthened (IN740) materials. Some concerns are evident regarding the diffusion of aluminum in dissimilar joints during high temperature recrystallization treatments. It is noted that aggressive treatments rapidly deplete the corrosion protecting aluminum reservoir in the vicinity of the joint interface. Subsequently, the impact of varying PWHT has been evaluated in the context on ensuing creep performance.

Bimal Kad

2011-12-31T23:59:59.000Z

206

American Municipal Power (Public Electric Utilities) - Residential  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

American Municipal Power (Public Electric Utilities) - Residential American Municipal Power (Public Electric Utilities) - Residential Efficiency Smart Program (Ohio) American Municipal Power (Public Electric Utilities) - Residential Efficiency Smart Program (Ohio) < Back Eligibility Residential Savings Category Heating & Cooling Cooling Appliances & Electronics Commercial Lighting Lighting Water Heating Program Info Funding Source American Municipal Power Start Date 01/2011 Expiration Date 12/31/2013 State Ohio Program Type Utility Rebate Program Rebate Amount Ceiling Fan with Lights: $15 Dehumidifier: $25 Select Clothes Washer: $50 ENERGY STAR Refrigerator: $50 Refrigerator/Freezer Recycling: $50 Furnace Fan with ECM: $100 Heat Pump Water Heaters: $250 CFLs: up to 85% of cost Efficiency Smart (tm) provides energy efficiency incentives to the American

207

Best Practices for Siting Solar Photovoltaics on Municipal Solid Waste Landfills. A Study Prepared in Partnership with the Environmental Protection Agency for the RE-Powering America's Land Initiative: Siting Renewable Energy on Potentially Contaminated Land and Mine Sites  

DOE Green Energy (OSTI)

The Environmental Protection Agency and the National Renewable Energy Laboratory developed this best practices document to address common technical challenges for siting solar photovoltaics (PV) on municipal solid waste (MSW) landfills. The purpose of this document is to promote the use of MSW landfills for solar energy systems. Closed landfills and portions of active landfills with closed cells represent thousands of acres of property that may be suitable for siting solar photovoltaics (PV). These closed landfills may be suitable for near-term construction, making these sites strong candidate to take advantage of the 30% Federal Business Energy Investment Tax Credit. It was prepared in response to the increasing interest in siting renewable energy on landfills from solar developers; landfill owners; and federal, state, and local governments. It contains examples of solar PV projects on landfills and technical considerations and best practices that were gathered from examining the implementation of several of these projects.

Kiatreungwattana, K.; Mosey, G.; Jones-Johnson, S.; Dufficy, C.; Bourg, J.; Conroy, A.; Keenan, M.; Michaud, W.; Brown, K.

2013-04-01T23:59:59.000Z

208

Indianola Municipal Utilities - Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Indianola Municipal Utilities - Energy Efficiency Rebate Program Indianola Municipal Utilities - Energy Efficiency Rebate Program Indianola Municipal Utilities - Energy Efficiency Rebate Program < Back Eligibility Commercial Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Central AC: $250 maximum; 10 unit maximum per customer per year Commercial Lighting: $5,000 per customer per year Air Source Heat Pumps: $500 maximum; 10 units per customer per year Geothermal Heat Pumps: $1,000 maximum, 5 units per customer per year Program Info State Iowa Program Type Utility Rebate Program Rebate Amount Central AC: $100/unit; $50 for each SEER above minimum Commercial Lighting: $2 - $25/fixture depending on type and efficiency

209

River Falls Municipal Utilities - Business Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

River Falls Municipal Utilities - Business Energy Efficiency Rebate River Falls Municipal Utilities - Business Energy Efficiency Rebate Program (Wisconsin) River Falls Municipal Utilities - Business Energy Efficiency Rebate Program (Wisconsin) < Back Eligibility Commercial Industrial Savings Category Other Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Cooling Construction Design & Remodeling Manufacturing Appliances & Electronics Sealing Your Home Ventilation Heat Pumps Commercial Lighting Lighting Water Heating Windows, Doors, & Skylights Program Info State Wisconsin Program Type Utility Rebate Program Rebate Amount Shared Savings Program: $2,500 - $50,000 Energy Improvement Incentive: Varies, Contact WPPI RFP for Energy Efficiency: Varies, Contact WPPI Efficient Lighting Program: Will match Focus on Energy incentive to $5,000

210

Denton Municipal Electric - GreenSense Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Denton Municipal Electric - GreenSense Energy Efficiency Rebate Denton Municipal Electric - GreenSense Energy Efficiency Rebate Program Denton Municipal Electric - GreenSense Energy Efficiency Rebate Program < Back Eligibility Commercial Construction Installer/Contractor Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Construction Design & Remodeling Heat Pumps Windows, Doors, & Skylights Maximum Rebate Solar Screens: $200 Energy Efficient Windows: $500 Programmable Thermostat: $50 Attic Insulation (Retrofit): $400 Attic Insulation (New Construction): $400 Program Info State Texas Program Type Utility Rebate Program Rebate Amount Central AC: $600/unit Central Heat Pumps: $700/unit Geothermal Heat Pumps: $700/unit Attic Reflective Radiant Barrier: $200 - $300

211

Marblehead Municipal Light Department - Residential Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Marblehead Municipal Light Department - Residential Energy Marblehead Municipal Light Department - Residential Energy Efficiency Rebate Program Marblehead Municipal Light Department - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Maximum Rebate Insulation: $1,600 Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount Refrigerators: $100, plus $25 for disposal of old refrigerator Clothes Washers: $50 - $100 Dishwashers: $25 - $50 Room A/C Units: 50% of purchase price up to $50 Central A/C: $325 - $525, varies by efficiency and technology Heat Pumps: $325 - $675, varies by efficiency and technology Programmable Thermostat: up to 50% of the purchase price

212

Space and Time Resolved Measurements of the Heating of Solids to Ten Million Kelvin by a Petawatt Laser  

Science Conference Proceedings (OSTI)

The heating of plane solid targets by the Vulcan petawatt laser at powers of 0.32-0.73 PW and intensities of up to 4 x 10^20 W cm^-2 has been diagnosed with a temporal resolution of 17 ps and a spatial resolution of 30 um, by measuring optical emission from the opposite side of the target to the laser with a streak camera. Second harmonic emission was filtered out and the target viewed at an angle to eliminate optical transition radiation. Spatial resolution was obtained by imaging the emission onto a bundle of fibre optics, arranged into a one-dimensional array at the camera entrance. The results show that a region 160 um in diameter can be heated to a temperature of ~10^7 K (kT/e ~ keV) in solid targets from 10 to 20 um thick and that this temperature is maintained for at least 20 ps, confirming the utility of PW lasers in the study of high energy density physics. Hybrid code modelling shows that magnetic field generation prevents increased target heating by electron refluxing above a certain target thickness and that the absorption of laser energy into electrons entering the solid target was between 15-30%, and tends to increase with laser energy.

Nakatsutsumi, M.; Davies, J.R.; Kodama, R.; Green, J.S.; Lancaster, K.L.; Akli, K.U.; Beg, F.N.; Chen, S.N.; Clark, D.; Freeman, R.R.; Gregory, C.D.; Habara, H.; Heathcote, R.; Hey, D.S.; Highbarger, K.; Jaanimagi, P.; Key, M.H.; Krushelnick, K.; Ma, T.; MacPhee, A.; MacKinnon, A.J.; Nakamura, H.; Stephens, R.B.; Storm, M.; Tampo, M.; Theobald, W.; Van Woerkom, L.; Weber, R.L.; Wei, M.S.; Woolsey, N.C.; Norreys, P.A.

2008-04-29T23:59:59.000Z

213

Evaluation of the Natick enzymatic hydrolysis process for use in the production of ethanol from municipal solid waste or from wood. Final report  

DOE Green Energy (OSTI)

Economic evaluation of a conceptual, large-scale, commercial ethanol production facility using the enzymatic hydrolysis technology are presented. Designs and cost estimates for the mechanical processing and the ethanol fermentation and recovery are included. Production of ethanol from both wood and solid wastes is covered. (MHR)

Jones, J. L.; Fong, W. S.; Chatterjee, A. K.

1979-10-01T23:59:59.000Z

214

Wellesley Municipal Light Plant - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Wellesley Municipal Light Plant - Residential Energy Efficiency Wellesley Municipal Light Plant - Residential Energy Efficiency Rebate Program Wellesley Municipal Light Plant - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Maximum Rebate Two equipment rebates per customer per calendar year Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount Refrigerator: $100 Clothes Washing Machine: $75 Central AC: $100 Room AC Unit: $50 Dishwasher: $75 Dehumidifier: $50 Provider Appliance Rebate Program Wellesley Municipal Light Plant (WMLP) offers a number of appliance rebates to residential customers who purchase and install energy efficient equipment. Rebates are available for refrigerators, dishwashers, clothes

215

Local Option - Municipal Sustainable Energy Programs | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Municipal Sustainable Energy Programs Municipal Sustainable Energy Programs Local Option - Municipal Sustainable Energy Programs < Back Eligibility Agricultural Commercial Industrial Institutional Multi-Family Residential Nonprofit Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Sealing Your Home Cooling Construction Design & Remodeling Other Windows, Doors, & Skylights Appliances & Electronics Commercial Lighting Lighting Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Solar Water Heating Wind Program Info State New York Program Type PACE Financing '''''Note: The Federal Housing Financing Agency (FHFA) issued a [http://www.fhfa.gov/webfiles/15884/PACESTMT7610.pdf statement] in July

216

Oklahoma Municipal Power Authority - WISE Energy Efficiency Loan Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Oklahoma Municipal Power Authority - WISE Energy Efficiency Loan Oklahoma Municipal Power Authority - WISE Energy Efficiency Loan Program Oklahoma Municipal Power Authority - WISE Energy Efficiency Loan Program < Back Eligibility Commercial Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Cooling Commercial Heating & Cooling Design & Remodeling Windows, Doors, & Skylights Ventilation Manufacturing Heat Pumps Appliances & Electronics Commercial Lighting Lighting Insulation Water Heating Program Info Funding Source American Recovery and Reinvestment Act of 2009 State Oklahoma Program Type Utility Loan Program Rebate Amount Unsecured Loan: $5,000 - $35,000 Home Equity Loan: $1,000 - $100,000 Provider Oklahoma Municipal Power Authority The Oklahoma Municipal Power Authority (OMPA) offers loans for a variety of

217

WASTE SEPARATION-DOES IT INFLUENCE MUNICIPAL WASTE COMBUSTOR EMISSIONS?  

E-Print Network (OSTI)

WASTE SEPARATION- DOES IT INFLUENCE MUNICIPAL WASTE COMBUSTOR EMISSIONS? A. John Chandler A a commendable job in proving that trace emissions from a modem waste to energy plant have little to do with the trace compounds in individual components of municipal solid waste. Ogden, the leader in designing

Columbia University

218

Alameda Municipal Power - Residential Energy Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Energy Efficiency Program Residential Energy Efficiency Program Alameda Municipal Power - Residential Energy Efficiency Program < Back Eligibility Low-Income Residential Multi-Family Residential Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Construction Commercial Heating & Cooling Design & Remodeling Maximum Rebate Single family, duplex, or triplex: $960 per unit Multi-family dwelling (four or more units): $480 per unit. Program Info State California Program Type Utility Grant Program Rebate Amount Weatherization: 80% of the cost Do-It-Yourself Weatherization: 70% of the cost Provider Alameda Municipal Power Alameda Municipal Power (AMP) offers a grant to help its residential customers who have electric heat weatherize homes to increase efficiency.

219

Solid Waste Disposal Act (Texas)  

Energy.gov (U.S. Department of Energy (DOE))

The Texas Commission on Environmental Quality is responsible for the regulation and management of municipal solid waste and hazardous waste. A fee is applied to all solid waste disposed in the...

220

Waverly Municipal Elec Utility | Open Energy Information  

Open Energy Info (EERE)

Municipal Elec Utility Municipal Elec Utility Jump to: navigation, search Name Waverly Municipal Elec Utility Place Iowa Utility Id 20214 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes ISO MISO Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Service Commercial Commercial and Municipal time of Use Service Commercial Electric Heat Rate for Residential Service Residential General Service General and Minicipal Demand Time of Use Service Commercial

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Heat Conduction  

Science Conference Proceedings (OSTI)

Table 2   Differential equations for heat conduction in solids...conduction in solids General form with variable thermal properties General form with constant thermal properties General form, constant properties, without heat

222

Willmar Municipal Utilities - Residential Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Willmar Municipal Utilities - Residential Energy Efficiency Rebate Willmar Municipal Utilities - Residential Energy Efficiency Rebate Program Willmar Municipal Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Water Heating Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Refrigerator: 50 Clothes Washer: 50 Dishwasher: 50 Central A/C: 200 Water Heater: 1.25/gallon (bonus 100 to convert to an electric water heater from another fuel source) Provider Willmar Municipal Utilities Willmar Municipal Utilities offer rebates on Energy Star rated appliances and air conditioners and Marathon water heaters. In addition to these rebates, WMU also offers a Load Sharing Program. Participating customers

223

Reading Municipal Light Department - Residential ENERGY STAR Appliance  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Reading Municipal Light Department - Residential ENERGY STAR Appliance Rebate Program Reading Municipal Light Department - Residential ENERGY STAR Appliance Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Cooling Commercial Heating & Cooling Appliances & Electronics Heat Pumps Water Heating Maximum Rebate One rebate per Energy Star appliance or two rebates on the purchase of programmable thermostats Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount Electric Heat Pump Water Heater: $250 Air Source Heat Pump: $100 Central AC: $100 Refrigerator: $50 Washing Machine: $50 Dishwasher: $50 Room A/C: $25 Dehumidifier: $25 Programmable Thermostat:$15 (limit 2) Ceiling Fan: $10

224

Wakefield Municipal Gas and Light Department - Residential Conservation  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Wakefield Municipal Gas and Light Department - Residential Wakefield Municipal Gas and Light Department - Residential Conservation Services Program Wakefield Municipal Gas and Light Department - Residential Conservation Services Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Design & Remodeling Windows, Doors, & Skylights Manufacturing Commercial Lighting Lighting Water Heating Maximum Rebate Energy Audit Recommended Measures: $300 Programmable Thermostats: 2 units Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount Energy Audit Recommended Measures: 25% of total cost Refrigerators: $50 Clothes Washer: $50 Dishwasher: $50 Room AC: $50

225

Numerical investigation of electric heating impacts on solid/liquid glass flow patterns.  

SciTech Connect

A typical glass furnace consists of a combustion space and a melter. Intense heat is generated from the combustion of fuel and air/oxygen in the combustion space. This heat is transferred mainly by radiation to the melter in order to melt sand and cullet (scrap glass) eventually creating glass products. Many furnaces use electric boosters to enhance glass melting and increase productivity. The coupled electric/combustion heat transfer patterns are key to the glass making processes. The understanding of the processes can lead to the improvement of glass quality and furnace efficiency. The effects of electrical boosting on the flow patterns and heat transfer in a glass melter are investigated using a multiphase Computational Fluid Dynamics (CFD) code with addition of an electrical boosting model. The results indicate that the locations and spacing of the electrodes have large impacts on the velocity and temperature distributions in the glass melter. With the same total heat input, the batch shape (which is determined by the overall heat transfer and the batch melting rate) is kept almost the same. This indicates that electric boosting can be used to replace part of heat by combustion. Therefore, temperature is lower in the combustion space and the life of the furnace can be prolonged. The electric booster can also be used to increase productivity without increasing the furnace size.

Chang, S. L.; Zhou, C. Q.; Golchert, B.

2002-07-02T23:59:59.000Z

226

Comparison of municipal solid waste management systems in Canada and Ghana: A case study of the cities of London, Ontario, and Kumasi, Ghana  

SciTech Connect

Integrated waste management has been accepted as a sustainable approach to solid waste management in any region. It can be applied in both developed and developing countries. The difference is the approach taken to develop the integrated waste management system. This review looks at the integrated waste management system operating in the city of London, Ontario-Canada and how lessons can be drawn from the system's development and operation that will help implement a sustainable waste management system in the city of Kumasi, Ghana. The waste management system in London is designed such that all waste generated in the city is handled and disposed of appropriately. The responsibility of each sector handling waste is clearly defined and monitored. All major services are provided and delivered by a combination of public and private sector forces. The sustainability of the waste management in the city of London is attributed to the continuous improvement strategy framework adopted by the city based on the principles of integrated waste management. It is perceived that adopting a strategic framework based on the principles of integrated waste management with a strong political and social will, can transform the current waste management in Kumasi and other cities in developing countries in the bid for finding lasting solutions to the problems that have plagued the waste management system in these cities.

Asase, Mizpah [Department of Chemical Engineering, Kwame Nkrumah University of Science and Technology, Kumasi (Ghana); Yanful, Ernest K. [Department of Civil and Environmental Engineering, The University of Western Ontario London, Ontario, N6A 5B9 (Canada)], E-mail: eyanful@eng.uwo.ca; Mensah, Moses [Department of Chemical Engineering, Kwame Nkrumah University of Science and Technology, Kumasi (Ghana); Stanford, Jay [City of London, 300 Dufferin Ave. P.O. Box 5035, Ontario, N6A 4L9 (Canada); Amponsah, Samuel [Mathematics Department, Kwame Nkrumah University of Science and Technology, Kumasi (Ghana)

2009-10-15T23:59:59.000Z

227

Municipal Utility Districts (Texas)  

Energy.gov (U.S. Department of Energy (DOE))

Municipal Utility Districts, regulated by the Texas Commission on Environmental Quality, may be created for the following purposes: (1) the control, storage, preservation, and distribution of its...

228

Optimization of the controlling design parameters of fluidised bed gas-solid heat exchangers  

Science Conference Proceedings (OSTI)

Generalised analytical correlations relating heat transfer coefficient, mass velocity of gas, tube diameter, bed particle size and relative pitch have been formulated based on experimental data reported in literature. These correlations are used to predict ...

V. N. Vedamurthy; T. Janakirajan; S. Natarajan; C. P. Sarathy

1990-12-01T23:59:59.000Z

229

Prospects for pyrolysis technologies in managing municipal, industrial, and DOE cleanup wastes  

DOE Green Energy (OSTI)

Pyrolysis converts portions of municipal solid wastes, hazardous wastes, and special wastes such as tires, medical wastes, and even old landfills into solid carbon and a liquid or gaseous hydrocarbon stream. Pyrolysis heats a carbonaceous waste stream typically to 290--900 C in the absence of oxygen, and reduces the volume of waste by 90% and its weight by 75%. The solid carbon char has existing markets as an ingredient in many manufactured goods, and as an adsorbent or filter to sequester certain hazardous wastes. Pyrolytic gases may be burned as fuel by utilities, or liquefied for use as chemical feedstocks, or low-pollution motor vehicle fuels and fuel additives. This report analyzes the potential applications of pyrolysis in the Long Island region and evaluates for the four most promising pyrolytic systems their technological and commercial readiness, their applicability to regional waste management needs, and their conformity with DOE requirements for environmental restoration and waste management. This summary characterizes their engineering performance, environmental effects, costs, product applications, and markets. Because it can effectively treat those wastes that are inadequately addressed by current systems, pyrolysis can play an important complementing role in the region`s existing waste management strategy. Its role could be even more significant if the region moves away from existing commitments to incineration and MSW composting. Either way, Long Island could become the center for a pyrolysis-based recovery services industry serving global markets in municipal solid waste treatment and hazardous waste cleanup. 162 refs.

Reaven, S.J. [State Univ. of New York, Stony Brook, NY (United States)

1994-12-01T23:59:59.000Z

230

Homogeneous Non-Equilibrium Molecular Dynamics Methods for Calculating the Heat Transport Coefficient of Solids and Mixtures  

E-Print Network (OSTI)

Heat Conduction in an ElasticHeat Conduction in Liquid Mixtures . . . . . . .1 Introduction Heat conduction is a process involving

Mandadapu, Kranthi Kiran

2011-01-01T23:59:59.000Z

231

City of Greensburg - Green Building Requirement for New Municipal Buildings  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Greensburg - Green Building Requirement for New Municipal Greensburg - Green Building Requirement for New Municipal Buildings City of Greensburg - Green Building Requirement for New Municipal Buildings < Back Eligibility Local Government Savings Category Heating & Cooling Home Weatherization Construction Commercial Weatherization Commercial Heating & Cooling Design & Remodeling Bioenergy Solar Lighting Windows, Doors, & Skylights Alternative Fuel Vehicles Hydrogen & Fuel Cells Heating Buying & Making Electricity Water Water Heating Wind Program Info State Kansas Program Type Energy Standards for Public Buildings Provider Greensburg City Hall In the aftermath of a May 2007 tornado that destroyed 95% of the city, the Greensburg City Council passed an ordinance requiring that all newly constructed or renovated municipally owned facilities larger than 4,000

232

River Falls Municipal Utilities - Non-Profit Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

River Falls Municipal Utilities - Non-Profit Energy Efficiency River Falls Municipal Utilities - Non-Profit Energy Efficiency Rebate Program (Wisconsin) River Falls Municipal Utilities - Non-Profit Energy Efficiency Rebate Program (Wisconsin) < Back Eligibility Nonprofit Savings Category Other Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Cooling Construction Design & Remodeling Appliances & Electronics Sealing Your Home Windows, Doors, & Skylights Heat Pumps Commercial Lighting Lighting Manufacturing Maximum Rebate 60% of project cost, up to $5,000 Program Info Funding Source POWERful Choices Initiative Expiration Date 12/31/2012 State Wisconsin Program Type Utility Rebate Program Rebate Amount Incentive equal to Focus on Energy Incentive River Falls Municipal Utility (RFMU) provides matching rebates to

233

Concord Municipal Light Plant - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Concord Municipal Light Plant - Residential Energy Efficiency Concord Municipal Light Plant - Residential Energy Efficiency Rebate Program Concord Municipal Light Plant - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Sealing Your Home Ventilation Commercial Lighting Lighting Maximum Rebate Electric Heat Weatherization: $1,000 Central Air Conditioners: $1,500 CFLs/LEDs/Exit Signs: 30 bulbs or signs Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount Electric Heat Weatherization: $1,000 Central Air Conditioners: $1,500 CFLs/LEDs/Exit Signs: 30 bulbs or signs Provider Customer Service Concord Municipal Light Plant (CMLP) offers its residential customers

234

Concord Municipal Light Plant- Commercial Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Concord Municipal Light Plant (CMLP) offers rebates to commercial customers for a variety of appliances, ETS heating systems, general lighting upgrades, CFL bulbs, and exit sign retrofit kits. A...

235

Anaerobic co-digestion of the organic fraction of municipal solid waste with FOG waste from a sewage treatment plant: Recovering a wasted methane potential and enhancing the biogas yield  

SciTech Connect

Anaerobic digestion is applied widely to treat the source collected organic fraction of municipal solid wastes (SC-OFMSW). Lipid-rich wastes are a valuable substrate for anaerobic digestion due to their high theoretical methane potential. Nevertheless, although fat, oil and grease waste from sewage treatment plants (STP-FOGW) are commonly disposed of in landfill, European legislation is aimed at encouraging more effective forms of treatment. Co-digestion of the above wastes may enhance valorisation of STP-FOGW and lead to a higher biogas yield throughout the anaerobic digestion process. In the present study, STP-FOGW was evaluated as a co-substrate in wet anaerobic digestion of SC-OFMSW under mesophilic conditions (37 {sup o}C). Batch experiments carried out at different co-digestion ratios showed an improvement in methane production related to STP-FOGW addition. A 1:7 (VS/VS) STP-FOGW:SC-OFMSW feed ratio was selected for use in performing further lab-scale studies in a 5 L continuous reactor. Biogas yield increased from 0.38 {+-} 0.02 L g VS{sub feed}{sup -1} to 0.55 {+-} 0.05 L g VS{sub feed}{sup -1} as a result of adding STP-FOGW to reactor feed. Both VS reduction values and biogas methane content were maintained and inhibition produced by long chain fatty acid (LCFA) accumulation was not observed. Recovery of a currently wasted methane potential from STP-FOGW was achieved in a co-digestion process with SC-OFMSW.

Martin-Gonzalez, L., E-mail: lucia.martin@uab.ca [Departament d'Enginyeria Quimica, Universitat Autonoma de Barcelona, 08193 Bellaterra (Spain); Colturato, L.F. [Departament d'Enginyeria Quimica, Universitat Autonoma de Barcelona, 08193 Bellaterra (Spain); Font, X.; Vicent, T. [Departament d'Enginyeria Quimica, Universitat Autonoma de Barcelona, 08193 Bellaterra (Spain); Institut de Ciencia i Tecnologia Ambiental (ICTA) Universitat Autonoma de Barcelona, 08193 Bellaterra (Spain)

2010-10-15T23:59:59.000Z

236

Municipal Waste Combustion (New Mexico)  

Energy.gov (U.S. Department of Energy (DOE))

This rule establishes requirements for emissions from, and design and operation of, municipal waste combustion units. "Municipal waste" means all materials and substances discarded from residential...

237

Nuclear heat-load limits for above-grade storage of solid transuranium wastes  

SciTech Connect

Nuclear safety and heat load limits were established for above-grade storage of transuranium (TRU) wastes. Nuclear safety limits were obtained from a study by J.L. Forstner and are summarized. Heat load limits are based on temperature calculations for TRU waste drums stored in concrete containers (hats), and results are summarized. Waste already in storage is within these limits. The limiting factors for individual drum heat load limits were (1) avoidance of temperatures in excess of 190/sup 0/F (decomposition temperature of anion resin) when anion resin is present in a concrete hat, and (2) avoidance of temperatures in excess of 450/sup 0/F (ignition temperature of paper) at any point inside a waste drum. The limiting factor for concrete had heat load limits was avoidance of temperatures in excess of 265/sup 0/F (melt point of high density polyethylene) at the drum liners. A temperature profile for drums and hats filled to recommended limits is shown. Equations and assumptions used were conservative.

Clontz, B.G.

1978-06-01T23:59:59.000Z

238

Alameda Municipal Power - Commercial Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alameda Municipal Power - Commercial Energy Efficiency Rebate Alameda Municipal Power - Commercial Energy Efficiency Rebate Program Alameda Municipal Power - Commercial Energy Efficiency Rebate Program < Back Eligibility Commercial Fed. Government Local Government Nonprofit State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Commercial Lighting Lighting Manufacturing Home Weatherization Windows, Doors, & Skylights Maximum Rebate Contact utility regarding maximum incentive amounts Program Info State California Program Type Utility Rebate Program Rebate Amount Custom Rebates (Motors): $0.09/kWh Custom Rebates (Lighting): $0.15/kWh Custom Rebates (HVAC, Refrigeration, Networks): $0.11/kWh HVAC System: 50% of the difference in cost between Title 24 required

239

Lassen Municipal Utility District - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lassen Municipal Utility District - Residential Energy Efficiency Lassen Municipal Utility District - Residential Energy Efficiency Rebate Program Lassen Municipal Utility District - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Water Heating Maximum Rebate Windows: $500 Duct Insulation/Sealing: $500 Radiant Barrier: $1,000 Program Info State California Program Type Utility Rebate Program Rebate Amount Refrigerator: $50 Freezer: $50 Clothes Washer: $35 Dishwasher: $35 Room AC: $75 Air Source Heat Pumps: $100 - $400 per ton Ground Source Heat Pump: $1,000 per ton Central A/C: $25 - $150 per ton Evaporative Cooled A/C: $175 per ton Evaporative Coolers: $75 - $200 per 1,000 sq. ft.

240

Marshall Municipal Utilities - Residential Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Marshall Municipal Utilities - Residential Energy Efficiency Rebate Marshall Municipal Utilities - Residential Energy Efficiency Rebate Program Marshall Municipal Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Home Weatherization Construction Commercial Weatherization Design & Remodeling Heat Pumps Commercial Lighting Lighting Water Heating Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: $0.20/watt Holiday Light String: $3.50/string Clothes Washer: $100 Dishwasher: $50 Refrigerator/Freezer: $50 Room A/C: $25 Dehumidifier: $10 Central A/C: $100/ton Air-source Heat Pump: $150/ton Geothermal Heat Pump: $200/ton Electric Water Heater: $50; $100 (new construction or conversion)

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Northern Municipal Power Agency - Commercial Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Northern Municipal Power Agency - Commercial Energy Efficiency Northern Municipal Power Agency - Commercial Energy Efficiency Rebate Program (Minnesota) Northern Municipal Power Agency - Commercial Energy Efficiency Rebate Program (Minnesota) < Back Eligibility Commercial Industrial Institutional Local Government Nonprofit State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Other Heating Heat Pumps Commercial Lighting Lighting Manufacturing Water Heating Maximum Rebate $15,000 per customer, per calendar year. Incentives over $10,000 need pre-approval from the utility Total incentive not to exceed 75% of the project cost Geothermal Heat Pumps: $7,500 (open loop); $15,000 (closed loop) Programmable Thermostats: $2,500 per facility, up to 50% of the unit cost

242

Characterization of Solid State Phase Transformation in Continuously Heated and Cooled Ferritic Weld Metal  

Science Conference Proceedings (OSTI)

Arc welding processes involve cooling rates that vary over a wide range (1-100 K/s). The final microstructire is thus a product of the heating and cooling cycles experienced by the weld in addition to the weld composition. It has been shown that the first phase to form under weld cooling conditions may not be that predicted by equilibrium calculations. The partitioning of different interstitial/substitutional alloying elements at high temperatures can dramatically affect the subsequent phase transformations. In order to understand the effect of alloying on phase transformation temperatures and final microstructures time-resolved X-ray diffraction technique has been successfully used for characterization. The work by Jacot and Rappaz on pearlitic steels provided insight into austenitization of hypoeutectic steels using a finite volume model. However there is very little work done on the effect of heating and cooling rates on the phase transformation paths in bainitic/martensitic steels and weld metals. Previous work on a weld with higher aluminum content, deposited with a FCAW-S process indicated that even at aluminum levels where the primary phase to solidify from liquid should be delta ferrite, non-equilibrium austenite was observed. The presence of inhomogeneity in composition of the parent microstructure has been attributed to differences in transformation modes, temperatures and microstructures in dual-phase, TRIP steels and ferritic welds. The objectives of the work included the identification of the stability regions of different phases during heating and cooling, differences in the effect of weld heating and cooling rates on the phase transformation temperatures, and the variation in phase fractions of austenite and ferrite in the two phase regions as a function of temperature. The base composition used for the present work is a Fe-1%Al-2%Mn-1%Ni-0.04%C weld metal. A pseudo-binary phase diagram shows the expected solidification path under equilibrium conditions. However, the effect of heating and cooling rates on the phase transformation path due to non-equilibrium partitioning of alloying elements cannot be predicted by equilibrium phase diagrams. Also, it is unclear if there is retention of delta ferrite to room temperature due to compositional or thermal effects. This would dramatically affect the austenite to ferrite transformation due to carbon and nitrogen enrichment in the austenite.

Narayana, B [Ohio State University, The, Columbus; Mills, Michael J. [Ohio State University, The, Columbus; Specht, Eliot D [ORNL; Santella, Michael L [ORNL; Babu, Sudarsanam Suresh [Ohio State University, The, Columbus

2010-12-01T23:59:59.000Z

243

Geothermal heat pumps in Pierre  

SciTech Connect

There are two municipal connected heat pumps in Pierre, South Dakota: the South Dakota Discovery Center and Pierre City Hall.Both systems now utilize plate heat exchanger between the city water loop and the building loop. This article describes the geothermal system used in Pierre for both space heating and cooling of municipal buildings.

Wegman, S. [South Dakota Public Utilities Commission, Pierre, SD (United States)

1997-12-01T23:59:59.000Z

244

3D CFD Electrochemical and Heat Transfer Model of an Integrated-Planar Solid Oxide Electrolysis Cells  

DOE Green Energy (OSTI)

A three-dimensional computational fluid dynamics (CFD) electrochemical model has been created to model high-temperature electrolysis cell performance and steam electrolysis in a new novel integrated planar porous-tube supported solid oxide electrolysis cell (SOEC). The model is of several integrated planar cells attached to a ceramic support tube. This design is being evaluated with modeling at the Idaho National Laboratory. Mass, momentum, energy, and species conservation and transport are provided via the core features of the commercial CFD code FLUENT. A solid-oxide fuel cell (SOFC) model adds the electrochemical reactions and loss mechanisms and computation of the electric field throughout the cell. The FLUENT SOFC user-defined subroutine was modified for this work to allow for operation in the SOEC mode. Model results provide detailed profiles of temperature, Nernst potential, operating potential, activation over-potential, anode-side gas composition, cathode-side gas composition, current density and hydrogen production over a range of stack operating conditions. Mean per-cell area-specific-resistance (ASR) values decrease with increasing current density. Predicted mean outlet hydrogen and steam concentrations vary linearly with current density, as expected. Effects of variations in operating temperature, gas flow rate, cathode and anode exchange current density, and contact resistance from the base case are presented. Contour plots of local electrolyte temperature, current density, and Nernst potential indicated the effects of heat transfer, reaction cooling/heating, and change in local gas composition. Results are discussed for using this design in the electrolysis mode. Discussion of thermal neutral voltage, enthalpy of reaction, hydrogen production, cell thermal efficiency, cell electrical efficiency, and Gibbs free energy are discussed and reported herein.

Grant Hawkes; James E. O'Brien

2008-10-01T23:59:59.000Z

245

Indianola Municipal Utilities | Open Energy Information  

Open Energy Info (EERE)

Indianola Municipal Utilities Indianola Municipal Utilities Jump to: navigation, search Name Indianola Municipal Utilities Place Iowa Utility Id 9275 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Distribution Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Rates Commercial Electric Heat Source Commercial Government Commercial Large Industrial Industrial Outside City Limits Residential Residential Rates Residential Small Industrial Industrial

246

Dublin Municipal Electric Util | Open Energy Information  

Open Energy Info (EERE)

Dublin Municipal Electric Util Dublin Municipal Electric Util Jump to: navigation, search Name Dublin Municipal Electric Util Place Indiana Utility Id 5392 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Commercial General Power Rate OL: Outdoor Lighting (Security Lights) Lighting Rate SL: Street Lighting, All Public Street Lighting Lighting Rate SL: Street Lighting, State Highway Stoplight Lighting Residential Residential Residential: Space Heating and/or Air Conditioning Service Residential

247

Willmar Municipal Utilities | Open Energy Information  

Open Energy Info (EERE)

Municipal Utilities Municipal Utilities Jump to: navigation, search Name Willmar Municipal Utilities Place Minnesota Website wmu.willmar.mn.us/main/ Utility Id 20737 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes ISO MISO Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General service rate Commercial Heat pump rate Commercial Industrial(≥500KW;Primary Service) Industrial Industrial;≥500KW(Secondary Service) Industrial

248

Clean energy from municipal solid waste  

DOE Green Energy (OSTI)

This progress report describes a slurry grinding trial where a carbonized refuse derived fuel was dispersed in water. The RDF slurry produced in this study is to subjected to dioxin combustion tests.

Klosky, M.

1996-07-02T23:59:59.000Z

249

High solids fermentation reactor  

DOE Patents (OSTI)

A fermentation reactor and method for fermentation of materials having greater than about 10% solids. The reactor includes a rotatable shaft along the central axis, the shaft including rods extending outwardly to mix the materials. The reactor and method are useful for anaerobic digestion of municipal solid wastes to produce methane, for production of commodity chemicals from organic materials, and for microbial fermentation processes.

Wyman, Charles E. (Lakewood, CO); Grohmann, Karel (Littleton, CO); Himmel, Michael E. (Littleton, CO); Richard, Christopher J. (Lakewood, CO)

1993-01-01T23:59:59.000Z

250

Saint Peter Municipal Utilities - Residential Energy Efficiency Rebate  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Saint Peter Municipal Utilities - Residential Energy Efficiency Saint Peter Municipal Utilities - Residential Energy Efficiency Rebate Program Saint Peter Municipal Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Commercial Fed. Government Local Government Nonprofit Residential State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: See program website Room A/C: $25, plus $25 for recycling an old, working unit Central A/C: $100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Air Source Heat Pump:$100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Geothermal Heat Pump:$200/ton, plus $25/ton for every 1 EER above minimum

251

Cape Light Compact - Commercial, Industrial and Municipal Buildings Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Cape Light Compact - Commercial, Industrial and Municipal Buildings Cape Light Compact - Commercial, Industrial and Municipal Buildings Energy Efficiency Rebate Program Cape Light Compact - Commercial, Industrial and Municipal Buildings Energy Efficiency Rebate Program < Back Eligibility Commercial Industrial Local Government Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Manufacturing Other Construction Heat Pumps Appliances & Electronics Commercial Lighting Lighting Commercial Weatherization Water Heating Maximum Rebate Retrofit: 50% of cost of upgraded equipment, or an amount that buys down the cost of the project to a 1.5 year simple payback. New Construction: 70% of incremental cost of higher efficiency equipment, or an amount that buys down the incremental investment to a 1.5 year simple

252

Mora Municipal Utilities - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Mora Municipal Utilities - Residential Energy Efficiency Rebate Mora Municipal Utilities - Residential Energy Efficiency Rebate Program Mora Municipal Utilities - Residential Energy Efficiency Rebate Program < Back Eligibility Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: See program website Room A/C: $25, plus $25 for recycling an old, working unit Central A/C: $100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Air Source Heat Pump: $100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Geothermal Heat Pump: $200/ton, plus $25/ton for every 1 EER above minimum required EER

253

River Falls Municipal Utilities - Energy Star Appliance Rebates |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

River Falls Municipal Utilities - Energy Star Appliance Rebates River Falls Municipal Utilities - Energy Star Appliance Rebates River Falls Municipal Utilities - Energy Star Appliance Rebates < Back Eligibility Low-Income Residential Multi-Family Residential Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Home Weatherization Commercial Weatherization Cooling Construction Design & Remodeling Sealing Your Home Ventilation Heat Pumps Appliances & Electronics Commercial Lighting Lighting Water Heating Other Program Info Start Date 05/01/2010 Expiration Date 12/31/12 State Wisconsin Program Type Utility Rebate Program Rebate Amount Tree Planting: 50% of cost up to $50 (limit 3 trees) Freezer Recycling: $30 Refrigerator Recycling: $30 Energy Star Home Performance: 33.3% up to $1,500 15% Energy Savings from Installed Measures: $200

254

North Branch Municipal Water and Light - Residential Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

North Branch Municipal Water and Light - Residential Energy North Branch Municipal Water and Light - Residential Energy Efficiency Rebate Program North Branch Municipal Water and Light - Residential Energy Efficiency Rebate Program < Back Eligibility Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting: See program website Room A/C: $25, plus $25 for recycling an old, working unit Central A/C: $100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Air Source Heat Pump:$100 - $200, plus additional rebate for efficiency ratings above 14.5 SEER Geothermal Heat Pump:$200/ton, plus $25/ton for every 1 EER above minimum

255

Managing America`s solid waste  

Science Conference Proceedings (OSTI)

This report presents an historical overview of the federal role in municipal solid waste management from 1965 to approximately 1995. Attention is focuses on the federal role in safeguarding public health, protecting the environment, and wisely using material and energy resources. It is hoped that this report will provide important background for future municipal solid waste research and development initiatives.

Not Available

1998-03-02T23:59:59.000Z

256

A Generalized Pyrolysis Model for Combustible Solids  

E-Print Network (OSTI)

surface heat losses, heat conduction to the interior of the2.3.1 Solid phase heat conduction Thermophysical propertiesequation similar to the heat conduction equation. The model

Lautenberger, Chris

2007-01-01T23:59:59.000Z

257

Wyandotte Municipal Serv Comm | Open Energy Information  

Open Energy Info (EERE)

Wyandotte Municipal Serv Comm Wyandotte Municipal Serv Comm Place Michigan Utility Id 21048 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png HEATING STEAM RATE Residential HOT WATER DISTRICT HEATING RATE Commercial LARGE GENERAL SERVICE RATE Commercial Commercial LARGE GENERAL SERVICE RATE Commercial (Time-Differentiated Meter) Commercial LARGE GENERAL SERVICE RATE Industrial (Time-Differentiated Meter)

258

Characterization and Quantification of Electronic and Ionic Ohmic Overpotential and Heat Generation in a Solid Oxide Fuel Cell Anode  

Science Conference Proceedings (OSTI)

The development of a solid oxide fuel cell (SOFC) with a higher efficiency and power density requires an improved understanding and treatment of the irreversibilities. Losses due to the electronic and ionic resistances, which are also known as ohmic losses in the form of Joule heating, can hinder the SOFC's performance. Ohmic losses can result from the bulk material resistivities as well as the complexities introduced by the cell's microstructure. In this work, two-dimensional (2D), electronic and ionic transport models are used to develop a method of quantification of the ohmic losses within the SOFC anode microstructure. This quantification is completed as a function of properties determined from a detailed microstructure characterization, namely, the tortuosity of the electronic and ionic phases, phase volume fraction, contiguity, and mean free path. A direct modeling approach at the level of the pore-scale microstructure is achieved through the use of a representative volume element (RVE) method. The correlation of these ohmic losses with the quantification of the SOFC anode microstructure are examined. It is found with this analysis that the contributions of the SOFC anode microstructure on ohmic losses can be correlated with the volume fraction, contiguity, and mean free path.

Grew, Kyle N.; Izzo, John R.; Chiu, Wilson K.S.

2011-08-16T23:59:59.000Z

259

Homogeneous Non-Equilibrium Molecular Dynamics Methods for Calculating the Heat Transport Coefficient of Solids and Mixtures  

E-Print Network (OSTI)

b k ? ? T versible processes of heat transfer and diffusion,irreversible process of diffusion and heat transfer in theIntroduction Heat conduction is a process involving transfer

Mandadapu, Kranthi Kiran

2011-01-01T23:59:59.000Z

260

American Municipal Power (Public Electric Utilities) - Residential...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

American Municipal Power (Public Electric Utilities) - Residential Efficiency Smart Program (Ohio) American Municipal Power (Public Electric Utilities) - Residential Efficiency...

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Saint Peter Municipal Utilities - Commercial and Industrial Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Saint Peter Municipal Utilities - Commercial and Industrial Energy Saint Peter Municipal Utilities - Commercial and Industrial Energy Efficiency Rebate Program Saint Peter Municipal Utilities - Commercial and Industrial Energy Efficiency Rebate Program < Back Eligibility Commercial Fed. Government Industrial Local Government Nonprofit State Government Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Manufacturing Other Appliances & Electronics Heat Pumps Commercial Lighting Lighting Program Info Expiration Date 12/31/2012 State Minnesota Program Type Utility Rebate Program Rebate Amount Lighting Equipment: varies widely, see program website HVAC: see program website Replacement Motors: $15 - $2,700, varies by HP and efficiency Variable Speed Drives: $60 - $3,600, varies by HP and intended use Lodging Guestroom Energy Management Systems: $75 - $85

262

Elk River Municipal Utilities - Commercial Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Elk River Municipal Utilities - Commercial Energy Efficiency Rebate Elk River Municipal Utilities - Commercial Energy Efficiency Rebate Program Elk River Municipal Utilities - Commercial Energy Efficiency Rebate Program < Back Eligibility Agricultural Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Manufacturing Construction Heat Pumps Appliances & Electronics Commercial Lighting Lighting Other Maximum Rebate 50% of the project cost up to $100,000 Program Info State Minnesota Program Type Utility Rebate Program Rebate Amount Compressed Air: 50% of cost, up to $15,000 Motors (New): $5 - $15/hp Motors (Retrofit): $15/hp Variable Frequency Drives: $30/HP Chillers: $10 - $20/ton, plus $2 per 0.01 kW/ton below base Cooling Towers: $3/nominal tower ton Air Handling Systems: $170/VAV box

263

Solids mass flow determination  

DOE Patents (OSTI)

Method and apparatus for determining the mass flow rate of solids mixed with a transport fluid to form a flowing mixture. A temperature differential is established between the solids and fluid. The temperature of the transport fluid prior to mixing, the temperature of the solids prior to mixing, and the equilibrium temperature of the mixture are monitored and correlated in a heat balance with the heat capacities of the solids and fluid to determine the solids mass flow rate.

Macko, Joseph E. (Hempfield Township, Westmoreland County, PA)

1981-01-01T23:59:59.000Z

264

Atlantic Municipal Utilities | Open Energy Information  

Open Energy Info (EERE)

Atlantic Municipal Utilities Atlantic Municipal Utilities Place Iowa Utility Id 965 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes ISO MISO Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png All- Electric Residential (Single Phase) Residential All- Electric Residential (Three Phase) Residential Commercial All- Electric Commercial Commercial Supplemental Electric Heat Commercial Industrial Electric Service (over 2,000kW) Industrial

265

Energy utilization: municipal waste incineration. Final report  

SciTech Connect

An assessment is made of the technical and economical feasibility of converting municipal waste into useful and useable energy. The concept presented involves retrofitting an existing municipal incinerator with the systems and equipment necessary to produce process steam and electric power. The concept is economically attractive since the cost of necessary waste heat recovery equipment is usually a comparatively small percentage of the cost of the original incinerator installation. Technical data obtained from presently operating incinerators designed specifically for generating energy, documents the technical feasibility and stipulates certain design constraints. The investigation includes a cost summary; description of process and facilities; conceptual design; economic analysis; derivation of costs; itemized estimated costs; design and construction schedule; and some drawings.

LaBeck, M.F.

1981-03-27T23:59:59.000Z

266

Municipal Solid WasteMunicipal Solid Waste Landfills In CitiesLandfills In Cities  

E-Print Network (OSTI)

trench c) Liner Deployment d) Seaming Double Hot wedge Fillet Extrusion Seam properties ­ ASTM D6392 e-wise construction of landfill #12;Daily cell, cover, lift & phase of a landfill #12;Operational Points Provisions (contd) Check for compatibilities of different wastes. Divide landfill into cells. Non

Columbia University

267

Solid aerosol generator  

DOE Patents (OSTI)

An improved solid aerosol generator used to produce a gas borne stream of dry, solid particles of predetermined size and concentration. The improved solid aerosol generator nebulizes a feed solution of known concentration with a flow of preheated gas and dries the resultant wet heated aerosol in a grounded, conical heating chamber, achieving high recovery and flow rates.

Prescott, Donald S. (Shelley, ID); Schober, Robert K. (Midwest City, OK); Beller, John (Idaho Falls, ID)

1992-01-01T23:59:59.000Z

268

Quality Services: Solid Wastes, Part 360: Solid Waste Management Facilities  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0: Solid Waste Management 0: Solid Waste Management Facilities (New York) Quality Services: Solid Wastes, Part 360: Solid Waste Management Facilities (New York) < Back Eligibility Agricultural Commercial Fuel Distributor Industrial Institutional Investor-Owned Utility Multi-Family Residential Municipal/Public Utility Rural Electric Cooperative Transportation Utility Program Info State New York Program Type Environmental Regulations Provider NY Department of Environmental Conservation These regulations apply to all solid wastes with the exception of hazardous or radioactive waste. Proposed solid waste processing facilities are required to obtain permits prior to construction, and the regulations provide details about permitting, construction, registration, and operation requirements. The regulations contain specific guidance for land

269

Municipal waste processing apparatus  

DOE Patents (OSTI)

Municipal waste materials are processed by crushing the materials so that pieces of noncombustible material are smaller than a selected size and pieces of combustible material are larger than the selected size. The crushed materials are placed on a vibrating mesh screen conveyor belt having openings which pass the smaller, noncombustible pieces of material, but do not pass the larger, combustible pieces of material. Pieces of material which become lodged in the openings of the conveyor belt may be removed by cylindrical deraggers or pressurized air. The crushed materials may be fed onto the conveyor belt by a vibrating feed plate which shakes the materials so that they tend to lie flat.

Mayberry, J.L.

1987-01-15T23:59:59.000Z

270

Municipal waste processing apparatus  

DOE Patents (OSTI)

Municipal waste materials are processed by crushing the materials so that pieces of noncombustible material are smaller than a selected size and pieces of combustible material are larger than the selected size. The crushed materials are placed on a vibrating mesh screen conveyor belt having openings which pass the smaller, noncombustible pieces of material, but do not pass the larger, combustible pieces of material. Pieces of material which become lodged in the openings of the conveyor belt may be removed by cylindrical deraggers or pressurized air. The crushed materials may be fed onto the conveyor belt by a vibrating feed plate which shakes the materials so that they tend to lie flat.

Mayberry, John L. (Idaho Falls, ID)

1988-01-01T23:59:59.000Z

271

Municipal waste processing apparatus  

DOE Patents (OSTI)

Municipal waste materials are processed by crushing the materials so that pieces of noncombustible material are smaller than a selected size and pieces of combustible material are larger than the selected size. The crushed materials are placed on a vibrating mesh screen conveyor belt having openings which pass the smaller, noncombustible pieces of material, but do not pass the larger, combustible pieces of material. Consecutive conveyors may be connected by an intermediate vibratory plate. An air knife can be used to further separate materials based on weight.

Mayberry, John L. (Idaho Falls, ID)

1989-01-01T23:59:59.000Z

272

Anoka Municipal Utility - Residential Energy Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Anoka Municipal Utility - Residential Energy Efficiency Rebate Anoka Municipal Utility - Residential Energy Efficiency Rebate Program Anoka Municipal Utility - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Room Air Conditioner: limit of 2 units per account Lighting: limit of $15 per customer per year Program Info Expiration Date 03/31/2013 State Minnesota Program Type Utility Rebate Program Rebate Amount Ceiling Fan: $25 Clothes Washer: $25 Refrigerator: $50 Freezer: $50 Refrigerator/Freezer Recycling: $25 Freezer: $50 Dishwasher: $25 Dehumidifier: $25 Air Conditioner Tune-Up: $25 Room Air Conditioner: $25/unit Central A/C: $225 - $400, varies by efficiency

273

Municipal spotlight: Working together in Northern Virginia  

Science Conference Proceedings (OSTI)

The Northern Virginia region is one of the nation`s liveliest centers of commerce as measured by job creation, new business formation, residential and commercial construction, and retail sales. The region also has one of the most advanced integrated waste management programs. In 1994, more than 1.6 million tons of municipal solid (MSW) were generated in the Northern Virginia region. Of that amount, 1 million tons were recovered as energy and more than 500,000 tons were landfilled. Additionally, more than 500,000 tons were recycled. The jurisdictions in this region have built an extensive network of solid waste management programs that are handled on the local government level, through cooperative programs, and through implementation of unique interjurisdictional agreements. These programs are arranged in the following hierarchy: source reduction, composting, recycling, energy recovery, and landfilling. This article provides a description of how this hierarchy is implemented in the region.

Arner, R.

1995-10-01T23:59:59.000Z

274

Ontario Power Generation's 250 kWe Class Atmospheric Solid Oxide Fuel Cell (SOFC): Combined Heat and Power (CHP) Power Plant  

Science Conference Proceedings (OSTI)

This case study documents the demonstration experiences and lessons learned from a 250 kW solid oxide fuel cell system in a combined heat and power demonstration operating on natural gas. The project was a collaboration initiative between Siemens Westinghouse Power Corporation (SWPC) and Ontario Power Generation (OPG) to install and test a first-of-a-kind SOFC system at OPG site in Toronto, Canada. This test and evaluation case study is one of several distributed generation project case studies under res...

2005-01-26T23:59:59.000Z

275

Utah Municipal Power Agency | Open Energy Information  

Open Energy Info (EERE)

Login | Sign Up Search Page Edit with form History Facebook icon Twitter icon Utah Municipal Power Agency Jump to: navigation, search Name Utah Municipal Power Agency...

276

South Carolina Municipalities - Green Power Purchasing | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

South Carolina Municipalities - Green Power Purchasing South Carolina Municipalities - Green Power Purchasing South Carolina Municipalities - Green Power Purchasing < Back Eligibility Local Government Savings Category Bioenergy Solar Buying & Making Electricity Wind Program Info State South Carolina Program Type Green Power Purchasing Provider Santee Cooper Santee Cooper's Green Power Program was launched in September of 2001. All of the state's 20 electric cooperatives and the City of Georgetown participate in the Green Power Program, which is Green-e accredited. The renewable resources sold under the Green Power Program are comprised of 99% landfill gas (methane) and less than 1% solar energy. Santee Cooper is currently using landfill gas (methane) to produce electricity at six facilities in South Carolina: Horry Solid Waste

277

Performance comparison between partial oxidation and methane steam reforming processes for solid oxide fuel cell (SOFC) micro combined heat and  

E-Print Network (OSTI)

Performance comparison between partial oxidation and methane steam reforming processes for solid recirculation are used along with steam methane reforming. Further Steam Methane Reforming process produces Cell fueled by natural gas with two different types of pre-reforming systems, namely Steam Reforming

Liso, Vincenzo

278

Inorganic compounds for passive solar energy storage. Solid-state dehydration materials and high specific heat materials. Progress report  

DOE Green Energy (OSTI)

Two classes of hydrated inorganic salts have been studied to assess their potential as materials for passive solar energy storage. The materials are part of the quaternary system CaO-Al/sub 2/O/sub 3/-SO/sub 3/-H/sub 2/O and related chemical systems, and the two classes are typified by ettringite, a trisubstituted salt, and Friedel's salt, a monosubstituted salt. The trisubstituted salts were studied for their possible application in latent heat storage, utilizing a low-temperature dehydration reaction, and both classes were studies for their application in sensible heat storage. In order to assess their potential for energy storage, the salts have been synthesized, characterized by several analytical techniques, and thermal properties measured. The dehydration data of that the trisubstituted salts vary somewhat with chemical composition, with the temperature of the onset of dehydration ranging from 6/sup 0/C to 33/sup 0/C, and enthalpy changes on dehydration ranging from 60 to 200 cal/g. Heat capacity is less variable with composition; values for the trisubstituted phases are 30 cal/g//sup 0/C and for the monosubstituted phases between 0.23 and 0.28 cal/g//sup 0/C. Preliminary experiments indicate that the dehydration is reversible, and suggest that the materials might have additional potential as solar desiccant materials. These thermal data demonstrate the trisubstituted salts have potential as latent heat storage materials, and that both classes of salts have potential as sensible heat storage materials.

Struble, L.J.; Brown, P.W.

1986-04-01T23:59:59.000Z

279

ANALOG COMPUTATION OF TEMPERATURE DISTRIBUTION IN SOLIDS WITH ELECTRICAL HEAT-GENERATION AND TEMPERATURE-DEPENDENT PROPERTIES  

SciTech Connect

A problem which frequently arises in experimentai heat transfer work is that of determining the surface temperature of a tube in which heat is generated electrically. Solution of this problem involves a temperature measurement of the opposite surface to which a correction factor, the temperature drop through the tube wall, must be applied. This temperature drop is obtnined through the solution of the diffurential equation governing the temperature distribution in the tube wall; however, in the case of temperature-dependent properties of thermal conductivity and electrical resistivity, the governing equation is nonlinear, which necessitates special solutions. In this study a hypothetical surface-temperature problem was established, and the solution of the governing nonlinear differential equation was accomplished by means of an electronic analog computer. Assuming variable properties, the example used in this study was that of a one-dimensional steadystate heat flow through both a thick- and a thin- walled tube. (auth)

Harden, D.G.; Bryant, L.T.

1962-11-01T23:59:59.000Z

280

Municipalities and Renewable Energy Opportunities | Open Energy Information  

Open Energy Info (EERE)

Municipalities and Renewable Energy Opportunities Municipalities and Renewable Energy Opportunities Jump to: navigation, search BUILDING COMMUNITIES WITH RENEWABLE ENERGY --Rsiegent 20:06, 20 January 2010 (UTC) BC communities and renewable energy walk hand-in-hand. "Investments made today in established renewable energy technologies can reduce building operating costs, the savings of which can be allocated [for instance] to community programs." Municipal buildings are ideally suited, as they are built for the long-term with quality and durability, and social and environmental responsibility in mind. Renewable energy systems such as GeoExchange (geothermal heat pumps) and Solar Hot Water ("Solar") are common renewable energy technologies used in commercial scale buildings. They are durable, proven, and low

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Energy recovery from waste incineration: Assessing the importance of district heating networks  

SciTech Connect

Municipal solid waste incineration contributes with 20% of the heat supplied to the more than 400 district heating networks in Denmark. In evaluation of the environmental consequences of this heat production, the typical approach has been to assume that other (fossil) fuels could be saved on a 1:1 basis (e.g. 1 GJ of waste heat delivered substitutes for 1 GJ of coal-based heat). This paper investigates consequences of waste-based heat substitution in two specific Danish district heating networks and the energy-associated interactions between the plants connected to these networks. Despite almost equal electricity and heat efficiencies at the waste incinerators connected to the two district heating networks, the energy and CO{sub 2} accounts showed significantly different results: waste incineration in one network caused a CO{sub 2} saving of 48 kg CO{sub 2}/GJ energy input while in the other network a load of 43 kg CO{sub 2}/GJ. This was caused mainly by differences in operation mode and fuel types of the other heat producing plants attached to the networks. The paper clearly indicates that simple evaluations of waste-to-energy efficiencies at the incinerator are insufficient for assessing the consequences of heat substitution in district heating network systems. The paper also shows that using national averages for heat substitution will not provide a correct answer: local conditions need to be addressed thoroughly otherwise we may fail to assess correctly the heat recovery from waste incineration.

Fruergaard, T.; Christensen, T.H. [Department of Environmental Engineering, Technical University of Denmark, Kongens Lyngby (Denmark); Astrup, T., E-mail: tha@env.dtu.d [Department of Environmental Engineering, Technical University of Denmark, Kongens Lyngby (Denmark)

2010-07-15T23:59:59.000Z

282

Photovoltaics for municipal planners  

DOE Green Energy (OSTI)

This booklet is intended for city and county government personnel, as well as community organizations, who deal with supplying, regulating, or recommending electric power resources. Specifically, this document deals with photovoltaic (PV) power, or power from solar cells, which is currently the most cost-effective energy source for electricity requirements that are relatively small, located in isolated areas, or difficult to serve with conventional technology. Recently, PV has been documented to be more cost-effective than conventional alternatives (such as line extensions or engine generators) in dozens of applications within the service territories of electric, gas, and communications utilities. Here, we document numerous cost-effective urban applications, chosen by planners and utilities because they were the most cost-effective option or because they were appropriate for environmental or logistical reasons. These applications occur within various municipal departments, including utility, parks and recreation, traffic engineering, transportation, and planning, and they include lighting applications, communications equipment, corrosion protection, irrigation control equipment, remote monitoring, and even portable power supplies for emergency situations.

Not Available

1993-04-01T23:59:59.000Z

283

Santa Clara Water & Sewer- Solar Water Heating Program  

Energy.gov (U.S. Department of Energy (DOE))

In 1975, the City of Santa Clara established the nation's first municipal solar utility. Under the Solar Water Heating Program, the Santa Clara Water & Sewer Utilities Department supplies,...

284

Performance of solar heating and cooling systems: Solid desiccant cooling/fresh air heating with evacuated-tube collectors in CSU Solar House I  

DOE Green Energy (OSTI)

In keeping with the national energy policy goal of fostering an adequate supply of energy at a reasonable cost, the United States Department of Energy (DOE) supports a variety of programs to promote a balanced and mixed energy resource system. The mission of the DOE Solar Buildings Research and Development Program is to support this goal, by providing for the development of solar technology alternatives for the buildings sector. It is the goal of the Program to establish a proven technology base to allow industry to develop solar products and designs for buildings that are economically competitive and can contribute significantly to building energy supplies nationally. Toward this end, the program sponsors research activities related to increasing the efficiency, reducing the cost, and improving the long-term durability of passive and active solar systems for building water and space heating, cooling, and daylighting applications. These activities are conducted in four major areas: Advanced Passive Solar Materials Research, Collector Technology Research, Cooling Systems Research, and Systems Analysis and Applications Research.

Loef, G.O.G.; Beba, S.; Cler, G.; Birdsong, M.; McLay, B.

1988-11-01T23:59:59.000Z

285

Solid Waste Management (Indiana) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solid Waste Management (Indiana) Solid Waste Management (Indiana) Solid Waste Management (Indiana) < Back Eligibility Agricultural Commercial Industrial Investor-Owned Utility Local Government Municipal/Public Utility Rural Electric Cooperative State/Provincial Govt Utility Program Info State Indiana Program Type Environmental Regulations Provider Association of Indiana Solid Wastes Districts Inc. The state supports the implementation of source reduction, recycling, and other alternative solid waste management practices over incineration and land disposal. The Indiana Department of Environmental Management and the Indiana Solid Waste Management Board are tasked with planning and adopting rules and regulations governing solid waste management practices. Provisions pertaining to landfill management and expansion, permitting,

286

Solid Solution Lithium Alloy Cermet Anodes  

E-Print Network (OSTI)

Solid Solution Lithium Alloy Cermet Anodes Thomas J.94720 USA Abstract Lithium-magnesium solid solution alloysHeating mixtures of lithium nitride and magnesium provides a

Richardson, Thomas J.; Chen, Guoying

2006-01-01T23:59:59.000Z

287

Vehicle Technologies Office: Solid State Energy Conversion  

NLE Websites -- All DOE Office Websites (Extended Search)

Solid State Energy Conversion The Solid State Energy Conversion R&D activity is focused on developing advanced thermoelectric technologies for utilizing engine waste heat by...

288

Candidate chemical systems for air cooled, solar powered, absorption air conditioner design. Part II. Solid absorbents, high latent heat refrigerants  

DOE Green Energy (OSTI)

Work done in attempting to qualify absorption refrigeration systems based on refrigerants with intermediate latent heats of vaporization is summarized. In practice, these comprise methanol, ammonia, and methylamine. A wide variety of organic substances, salts, and mixtures were evaluated in as systematic a manner as possible. Several systems of interest are described. The system, LiClO/sub 3/--LiBr--H/sub 2/O, is a good back up system to our first choice of an antifreeze additive system, and thermodynamically promising but subject to some inconvenient materials limitations. The system, LiBr/ZnBr/sub 2/--methanol, is thermodynamically promising but requires additional kinetic qualification. Chemical stability of the system, LiCNS--ammonia/methylamine with various other third components, does not appear to be adequate for a long-lived system.

Biermann, W. J.

1978-04-01T23:59:59.000Z

289

SOLID WASTE MANAGEMENT PLAN  

E-Print Network (OSTI)

ACKNOWLEDGMENTS The Chelan County Public Works Department would like to thank the following organizations and individuals for their assistance in the development of this plan: ? Chelan County’s Solid Waste Council members, past and present, and the municipalities they represent. ? Chelan County’s Solid Waste Advisory Committee members, past and present, and the agencies and businesses they represented. ? the Chelan–Douglas Health District staff. ? Washington Department of Ecology staff. Chelan County residents and businesses also contributed to this document through comments provided during public meetings and through various other channels. The Board of County Commissioners and the Public Works Department gratefully acknowledge this input by the

unknown authors

2007-01-01T23:59:59.000Z

290

Greenhouse gases emission from municipal waste management: The role of separate collection  

Science Conference Proceedings (OSTI)

The municipal solid waste management significantly contributes to the emission in the atmosphere of greenhouse gases (e.g. CO{sub 2}, CH{sub 4}, N{sub 2}O) and therefore the management process from collection to treatment and disposal has to be optimized in order to reduce these emissions. In this paper, starting from the average composition of undifferentiated municipal solid waste in Italy, the effect of separate collection on greenhouse gases emissions from municipal waste management has been assessed. Different combinations of separate collection scenarios and disposal options (i.e. landfilling and incineration) have been considered. The effect of energy recovery from waste both in landfills and incinerators has also been addressed. The results outline how a separate collection approach can have a significant effect on the emission of greenhouse gases and how wise municipal solid waste management, implying the adoption of Best Available Technologies (i.e. biogas recovery and exploitation system in landfills and energy recovery system in Waste to Energy plants), can not only significantly reduce greenhouse gases emissions but, in certain cases, can also make the overall process a carbon sink. Moreover it has been shown that separate collection of plastic is a major issue when dealing with global warming relevant emissions from municipal solid waste management.

Calabro, Paolo S. [Dipartimento di Meccanica e Materiali, Universita degli Studi Mediterranea di Reggio Calabria, via Graziella - loc. Feo di Vito, 89122 Reggio Calabria (Italy)], E-mail: paolo.calabro@unirc.it

2009-07-15T23:59:59.000Z

291

New Castle Municipal Serv Comm | Open Energy Information  

Open Energy Info (EERE)

New Castle Municipal Serv Comm New Castle Municipal Serv Comm Place Delaware Utility Id 13424 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Space Heating (Grandfathered) Commercial Large General Service Commercial Demand Rate (Primary) Commercial Large General Service Commercial Demand Rate (Secondary) Commercial Medium General Service Commercial Demand Rate Commercial Residential Service Residential Residential Space Heating Residential Small General Service Commercial Non-Demand Rate Commercial

292

Table 8.3a Useful Thermal Output at Combined-Heat-and-Power Plants ...  

U.S. Energy Information Administration (EIA)

7 Batteries, chemicals, hydrogen, pitch, purchased steam, sulfur, miscellaneous technologies, and, beginning in 2001, non-renewable waste (municipal solid waste from ...

293

Illinois Municipal Electric Agency - Electric Efficiency Program...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electric Agency - Electric Efficiency Program < Back Eligibility Agricultural Commercial Industrial Institutional Municipal Utility Nonprofit Schools Savings Category Home...

294

Cape Light Compact - Commercial, Industrial and Municipal Buildings...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Industrial and Municipal Buildings Energy Efficiency Rebate Program Cape Light Compact - Commercial, Industrial and Municipal Buildings Energy Efficiency Rebate Program...

295

Community Renewable Energy Deployment: Sacramento Municipal Utility  

Open Energy Info (EERE)

Deployment: Sacramento Municipal Utility Deployment: Sacramento Municipal Utility District Projects Jump to: navigation, search Name Community Renewable Energy Deployment: Sacramento Municipal Utility District Projects Agency/Company /Organization US Department of Energy Focus Area Agriculture, Economic Development, Greenhouse Gas, Renewable Energy, Biomass - Anaerobic Digestion, Solar - Concentrating Solar Power, Solar, - Solar Pv, Biomass - Waste To Energy Phase Bring the Right People Together, Develop Finance and Implement Projects Resource Type Case studies/examples Availability Publicly available--Free Publication Date 2/2/2011 Website http://www1.eere.energy.gov/co Locality Sacramento Municipal Utility District, CA References Community Renewable Energy Deployment: Sacramento Municipal Utility District Projects[1]

296

American Municipal Power | Open Energy Information  

Open Energy Info (EERE)

Municipal Power Municipal Power Jump to: navigation, search Name American Municipal Power Place Columbus, Ohio Zip 43219 Product AMP is a non-profit corporation that owns and operates electric facilities. AMP purchases wholesale electric power and energy, and develops alternate power resources for its members. References American Municipal Power[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. American Municipal Power is a company located in Columbus, Ohio . References ↑ "American Municipal Power" Retrieved from "http://en.openei.org/w/index.php?title=American_Municipal_Power&oldid=342122" Categories: Clean Energy Organizations Companies Organizations Stubs

297

Alameda Municipal Power - Commercial New Construction Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Commercial New Construction Rebate Commercial New Construction Rebate Program Alameda Municipal Power - Commercial New Construction Rebate Program < Back Eligibility Commercial Construction Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Home Weatherization Construction Commercial Weatherization Design & Remodeling Heat Pumps Appliances & Electronics Commercial Lighting Lighting Manufacturing Maximum Rebate Assistance cannot exceed the actual cost of the project Program Info State California Program Type Utility Rebate Program Rebate Amount Design Assistance Grants: Up to $10,000/project Whole Building Approach Rebates: $0.10/kWh for buildings exceeding Title 24 by 10% $0.15/kWh for buildings exceeding Title 24 by 15% $0.20/kWh for buildings exceeding Title 24 by 20%

298

Modeling Space Heating Demand in Massachusetts’ Housing Stock and the Implications for Climate Change Mitigation Policy.  

E-Print Network (OSTI)

??This research examines variation in average household energy consumption for space heating in municipalities in Massachusetts in order to explore the magnitude of variation among… (more)

Robinson, Nathan H.

2011-01-01T23:59:59.000Z

299

Solid-State Lighting: 2011 Municipal Consortium Southwest Region...  

NLE Websites -- All DOE Office Websites (Extended Search)

and Market Assessment of Networked Outdoor Lighting Controls Mark Rehley, NEEA; Jordan Shackelford, Energy Solutions MSSLC Specification for Remote Monitoring and...

300

Municipal solid waste plants convert garbage to electricity ...  

U.S. Energy Information Administration (EIA)

Includes hydropower, solar, wind, geothermal, biomass and ethanol. Nuclear & Uranium. Uranium fuel, nuclear reactors, generation, spent fuel. Total Energy.

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

PYROLYSIS OF MUNICIPAL SOLID WASTE M. IGARASHI Y. HAYAFUNE  

E-Print Network (OSTI)

modern biomass can produce a bio-char by-product through pyrolysis which results in 30.6 kg C, pyrolysis and gasification of biomass. In the context of bio-char sequestration, only pyrolysis yields in bio-char was the type of biomass used for pyrolysis. Greater concentrations of lignin increased

Columbia University

302

Clean energy from municipal solid waste. Final report  

SciTech Connect

The aim of the project was to demonstrate the environmental and combustion performance advantages of a carbonized refuse derived fuel (RDF) slurry, produced from EnerTech`s slurry carbonization process, using continuous pilot scale equipment and its suitability as an alternative fuel for utility and industrial boilers.

Klosky, M.

1997-01-01T23:59:59.000Z

303

Engineering and Economic Evaluation of Municipal Solid Waste Technologies  

Science Conference Proceedings (OSTI)

In 2006, the Electric Power Research Institute (EPRI) initiated a project to conduct engineering and economic evaluations of renewable energy technologies, including wind, biomass, solar, geothermal, hydro, and ocean tidal and wave (Program 84). The goal of the evaluations is to develop an objective and consistent assessment of the current performance and project the future performance of the technologies with regard to thermal efficiency, capital and operation and maintenance costs, resource requirement...

2011-12-23T23:59:59.000Z

304

PYROLISIS OF MUNICIPAL SOLID WASTE M. IGARASHI Y. HAYAFUNE  

E-Print Network (OSTI)

-energy Pyrolysis is one of many technologies to produce energy from biomass (Bridgwater 2003). What distinguishes pyrolysis from alternative ways of converting biomass to energy is that pyrolysis produces a carbon-temperature pyrolysis"), using a variety of different reactor configurations. At these tem- peratures, biomass undergoes

Columbia University

305

Municipal solid waste management in Lahore City District, Pakistan  

SciTech Connect

This study deals with generation, composition, collection, transportation, and disposal, as well as the present cost of the waste management on the basis of 60% collection of the total waste and the cost of proposed improved system of management on the basis of 100% waste collection using the IWM-2 LCI model. A GIS map of Data Ganj Bakhsh Town (DGBT) of Lahore City District showing communal storage facilities is also provided. DGBT has a population of 1,624,169 living in 232,024 dwellings. The total waste generated per year is 500,000 tons, or 0.84/kg/cap/day. Presently 60% of the MSW is collected and disposed in open dumps, while 40% is not collected and lies along roadsides, streets railway lines, depressions, vacant plots, drains, storm drains and open sewers. In DGBT, 129 containers of 5-m{sup 3} capacity, 120 containers of 10-m{sup 3} capacity and 380 skips of 2.5-m{sup 3} capacity are placed for waste collection. The overall collection and disposal cost of the MSW of DGBT is $3,177,900/yr, which is $10.29/ton. Modeling was conducted using the IWM-2 model for improved collection and disposal on the basis of 100% service, compared to the current 60% service. The modelled cost is $8.3/per ton, which is 20% less than the present cost, but the overall cost of 100% collection and disposal increases to $4,155,737/yr.

Batool, Syeda Adila [Department of Space Science, Punjab University, Lahore (Pakistan)], E-mail: aadila_batool@yahoo.com; Muhammad Nawaz Ch [College of Earth and Environmental Sciences, University of the Punjab, Lahore (Pakistan)], E-mail: muhammadnawazchaudhry@yahoo.com

2009-06-15T23:59:59.000Z

306

Alternative Fuels Data Center: Municipal Alternative Fuel Tax Regulation  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Municipal Alternative Municipal Alternative Fuel Tax Regulation to someone by E-mail Share Alternative Fuels Data Center: Municipal Alternative Fuel Tax Regulation on Facebook Tweet about Alternative Fuels Data Center: Municipal Alternative Fuel Tax Regulation on Twitter Bookmark Alternative Fuels Data Center: Municipal Alternative Fuel Tax Regulation on Google Bookmark Alternative Fuels Data Center: Municipal Alternative Fuel Tax Regulation on Delicious Rank Alternative Fuels Data Center: Municipal Alternative Fuel Tax Regulation on Digg Find More places to share Alternative Fuels Data Center: Municipal Alternative Fuel Tax Regulation on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Municipal Alternative Fuel Tax Regulation

307

Mansfield Municipal Electric Department - Residential Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

50 Mansfield Municipal Electric Department encourages energy efficiency through the ENERGY STAR Appliance Rebate Incentive Program. Cash rebates are offered for ENERGY STAR...

308

Energy management in municipal street lighting  

SciTech Connect

This report presents strategies to reduce the energy used in street lighting and, at the same time, reduce or stabilize the cost of street lighting to municipalities.

1977-03-01T23:59:59.000Z

309

Reading Municipal Light Department - Residential Renewable Energy...  

Open Energy Info (EERE)

Summary Reading Municipal Light Department (RMLD) offers rebates of 1.00watt for solar photovoltaic and small wind installations for residential customers. A 0.25watt...

310

North Branch Municipal Water & Light - Commercial & Industrial...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

150 - 400 Dishwashers: 300 - 1,000 Ventilation Hood Controllers: 165HP Low-Flow Spray Valve: 50% of installed cost Southern Minnesota Municipal Power Agency (http:...

311

Mora Municipal Utilities - Commercial & Industrial Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

150 - 400 Dishwashers: 300 - 1,000 Ventilation Hood Controllers: 165HP Low-Flow Spray Valve: 50% of installed cost Southern Minnesota Municipal Power Agency (http:...

312

Saint Peter Municipal Utilities - Commercial & Industrial Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

150 - 400 Dishwashers: 300 - 1,000 Ventilation Hood Controllers: 165HP Low-Flow Spray Valve: 50% of installed cost Southern Minnesota Municipal Power Agency (http:...

313

Financing Strategies for Municipal Energy Efficiency.  

E-Print Network (OSTI)

??Energy efficiency represents a significant opportunity to reduce energy use, save money and reduce environmental impacts. For municipalities that are facing increasingly tight budgets and… (more)

Lubershane, Andrew

2011-01-01T23:59:59.000Z

314

Energy Efficiency Strategies for Municipal Wastewater Treatment...  

NLE Websites -- All DOE Office Websites (Extended Search)

for Municipal Wastewater Treatment Facilities J. Daw and K. Hallett National Renewable Energy Laboratory J. DeWolfe and I. Venner Malcolm Pirnie, the Water Division of ARCADIS...

315

Wellesley Municipal Light Plant - Residential Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Refrigerator: 100 Clothes Washing Machine: 75 Central AC: 100 Room AC Unit: 50 Dishwasher: 75 Dehumidifier: 50 Wellesley Municipal Light Plant (WMLP) offers a number of...

316

Cogeneration in municipalities. Workshop proceedings for local governments and municipal utilities  

Science Conference Proceedings (OSTI)

Five papers from workshops for local governments and municipal utilities are included. A separate abstract was prepared for each one.

Patterson, S. (ed.)

1982-01-01T23:59:59.000Z

317

Municipals  

NLE Websites -- All DOE Office Websites (Extended Search)

Hillsboro Hope Lakota Maddock Northwood Park River Riverdale Sharon Stanton Valley City South Dakota Aberdeen Arlington Aurora Badger Beresford Big Stone City Brookings Bryant...

318

Solid-State Lighting: Design Competitions  

NLE Websites -- All DOE Office Websites (Extended Search)

Market-Based Programs Printable Version Share this resource Send a link to Solid-State Lighting: Design Competitions to someone by E-mail Share Solid-State Lighting: Design Competitions on Facebook Tweet about Solid-State Lighting: Design Competitions on Twitter Bookmark Solid-State Lighting: Design Competitions on Google Bookmark Solid-State Lighting: Design Competitions on Delicious Rank Solid-State Lighting: Design Competitions on Digg Find More places to share Solid-State Lighting: Design Competitions on AddThis.com... LED Lighting Facts CALiPER Program Standards Development Technical Information Network Gateway Demonstrations Municipal Consortium Design Competitions Design Competitions National design competitions heighten awareness and market adoption of high-performance solid-state lighting products.

319

Factors determining municipal broadband strategies across Europe  

Science Conference Proceedings (OSTI)

Recognizing that high-speed broadband connectivity emerges as a key element for growth, city authorities engage in fiber access deployments to empower their local communities in the digital economy. Currently, a growing number of municipal fiber projects ... Keywords: Broadband, Europe, Infrastructure development, Municipal strategies

Costas Troulos; Vasilis Maglaris

2011-10-01T23:59:59.000Z

320

Feasibility study on the management of the disposal of Bangkok municipal waste. Final report  

SciTech Connect

In January, 1985, the Government of Thailand sought assistance from the United States Trade and Development Program (USTDP) to undertake a feasibility study to review and update the solid waste management master plan, with particular emphasis to be placed on waste disposal methods. In April, 1985, the USTDP engaged the firm of Engineering and Economic Research, Inc. to carry out a definitional/prefeasibility study to assess the potential of a project for solid waste management and energy production using municipal solid waste as fuel.

1989-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Hull Municipal Light Plant | Open Energy Information  

Open Energy Info (EERE)

Municipal Light Plant Municipal Light Plant Jump to: navigation, search Name Hull Municipal Light Plant Place Massachusetts Utility Id 8797 Utility Location Yes Ownership M NERC Location NPCC NERC NPCC Yes Operates Generating Plant Yes Activity Generation Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Area Lights Rate 150 WATT Lighting Area Lights Rate 250 WATT Lighting Area Lights Rate 400 WATT Lighting Large Power Rate 35 Industrial Large Power Taxable Rate 39 Industrial Municipal Lighting Rate 33 Lighting Municipal Rate 36 Commercial Residential Rate 31 Residential

322

Solid Cold - A  

NLE Websites -- All DOE Office Websites (Extended Search)

By the early 20th century, the way in which temperatures of solid objects changed as they absorbed heat was considered strong evidence that matter was not made of atoms. Einstein used some recent discoveries about light to turn this assessment around. A B C D E F A. A puzzle, and a surprising solution Take equal masses of lead and aluminum. Heat them until their temperatures are both 10 degrees higher. Will it take the same amount of heat for each? Back in the 18th century, the chemist Joseph Black discovered that different materials required different amounts of heat to raise their temperatures by equal amounts. The amount by which the temperature of a material changes as it absorbs or gives off heat can even be used to help identify the material. Among solid materials near room temperature,

323

Standards for Municipal Small Wind Regulations and Small Wind...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Standards for Municipal Small Wind Regulations and Small Wind Model Wind Ordinance Standards for Municipal Small Wind Regulations and Small Wind Model Wind Ordinance Eligibility...

324

Toward Energy Efficient Municipalities: General Comments on Policy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Toward Energy Efficient Municipalities: General Comments on Policy and Logistical Challenges to Smart Grid Implementation Toward Energy Efficient Municipalities: General Comments...

325

Exploring How Municipal Utilities Fund Solar Energy Projects...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Exploring How Municipal Utilities Fund Solar Energy Projects Webinar Exploring How Municipal Utilities Fund Solar Energy Projects Webinar February 19, 2013 1:00PM MST Webinar This...

326

Wakefield Municipal Gas & Light Department- Residential Conservation Services Program  

Energy.gov (U.S. Department of Energy (DOE))

The Wakefield Municipal Gas & Light Department (WMGLD), in cooperation with the Massachusetts Municipal Wholesale Electric Company (MMWEC), offers the "Incentive Rebate Program" to encourage...

327

Taunton Municipal Lighting Plant - Residential Energy Star Appliance...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Taunton Municipal Lighting Plant - Residential Energy Star Appliance Rebate Program Taunton Municipal Lighting Plant - Residential Energy Star Appliance Rebate Program Eligibility...

328

ESS 2012 Peer Review - Painesville Municipal Electric Power Vanadium...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Painesville Municipal Electric Power Vanadium Redox Battery Demonstration Project Jodi Startari Ashlawn Energy LLC Briefing Overview * Painesville Municipal Electric Power Plant...

329

Alternative Fuels Data Center: Municipal Alternative Fuel Vehicle (AFV)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Municipal Alternative Municipal Alternative Fuel Vehicle (AFV) Acquisition Requirements to someone by E-mail Share Alternative Fuels Data Center: Municipal Alternative Fuel Vehicle (AFV) Acquisition Requirements on Facebook Tweet about Alternative Fuels Data Center: Municipal Alternative Fuel Vehicle (AFV) Acquisition Requirements on Twitter Bookmark Alternative Fuels Data Center: Municipal Alternative Fuel Vehicle (AFV) Acquisition Requirements on Google Bookmark Alternative Fuels Data Center: Municipal Alternative Fuel Vehicle (AFV) Acquisition Requirements on Delicious Rank Alternative Fuels Data Center: Municipal Alternative Fuel Vehicle (AFV) Acquisition Requirements on Digg Find More places to share Alternative Fuels Data Center: Municipal Alternative Fuel Vehicle (AFV) Acquisition Requirements on AddThis.com...

330

Solid Waste Regulation No. 8 - Solid Waste Composting Facilities (Rhode  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Regulation No. 8 - Solid Waste Composting Facilities Regulation No. 8 - Solid Waste Composting Facilities (Rhode Island) Solid Waste Regulation No. 8 - Solid Waste Composting Facilities (Rhode Island) < Back Eligibility Commercial Industrial Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Utility Program Info State Rhode Island Program Type Environmental Regulations Provider Department of Environmental Management Facilities which compost putrescible waste and/or leaf and yard waste are subject to these regulations. The regulations establish permitting, registration, and operational requirements for composting facilities. Operational requirements for putrescible waste facilities include siting, distance, and buffer requirements, as well as standards for avoiding harm to endangered species and contamination of air and water sources. Specific

331

Lassen Municipal Utility District - Residential Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Efficiency Rebate Program Eligibility Residential Savings For Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps...

332

A new correlation for holdup in gas-solids cyclone  

Science Conference Proceedings (OSTI)

The performance of cyclone as gas to solids heat exchanger depends on the surface area of holdup of the solid particles inside the cyclone. Unlike the conventional heat exchangers where heat transfer area is fixed for a particular heat exchanger, heat ... Keywords: correlation, cyclone, holdup, marquardt-levenberg algorithm, regression

Anuj Jain; A. R. Paul; S. K. Aggarwal; B. Mohanty; B. P. Mani

2011-05-01T23:59:59.000Z

333

Elk River Municipal Utilities - Residential Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Heat Pumps Water Heating Program Info State Minnesota Program Type...

334

Osage Municipal Utilities Wind | Open Energy Information  

Open Energy Info (EERE)

Osage Municipal Utilities Wind Osage Municipal Utilities Wind Jump to: navigation, search Name Osage Municipal Utilities Wind Facility Osage Municipal Utilities Wind Sector Wind energy Facility Type Commercial Scale Wind Facility Status In Service Owner Osage Municipal Utilities Developer Osage Municipal Utilities Energy Purchaser Osage Municipal Utilities Location West of Osage IA Coordinates 43.298363°, -92.84096° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":43.298363,"lon":-92.84096,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

335

Solid Waste Management (Kansas) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solid Waste Management (Kansas) Solid Waste Management (Kansas) Solid Waste Management (Kansas) < Back Eligibility Commercial Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Utility Program Info State Kansas Program Type Environmental Regulations Provider Health and Environment This act aims to establish and maintain a cooperative state and local program of planning and technical and financial assistance for comprehensive solid waste management. No person shall construct, alter or operate a solid waste processing facility or a solid waste disposal area of a solid waste management system, except for clean rubble disposal sites, without first obtaining a permit from the secretary. Every person desiring to obtain a permit shall make application for such a permit on forms

336

Solid-State Lighting: LED Lighting Facts  

NLE Websites -- All DOE Office Websites (Extended Search)

Market-Based Programs Printable Version Share this resource Send a link to Solid-State Lighting: LED Lighting Facts to someone by E-mail Share Solid-State Lighting: LED Lighting Facts on Facebook Tweet about Solid-State Lighting: LED Lighting Facts on Twitter Bookmark Solid-State Lighting: LED Lighting Facts on Google Bookmark Solid-State Lighting: LED Lighting Facts on Delicious Rank Solid-State Lighting: LED Lighting Facts on Digg Find More places to share Solid-State Lighting: LED Lighting Facts on AddThis.com... LED Lighting Facts CALiPER Program Standards Development Technical Information Network Gateway Demonstrations Municipal Consortium Design Competitions LED Lighting Facts LED lighting facts - A Program of the U.S. DOE DOE's LED Lighting Facts® program showcases LED products for general

337

Louisiana Solid Waste Management and Resource Recovery Law (Louisiana) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Louisiana Solid Waste Management and Resource Recovery Law Louisiana Solid Waste Management and Resource Recovery Law (Louisiana) Louisiana Solid Waste Management and Resource Recovery Law (Louisiana) < Back Eligibility Agricultural Construction Developer Industrial Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Utility Program Info State Louisiana Program Type Environmental Regulations Provider Louisiana Department of Environmental Quality The Louisiana Department of Environmental Quality manages solid waste for the state of Louisiana under the authority of the Solid Waste Management and Resource Recover Law. The Department makes rules and regulations that establish standards governing the storage, collection, processing, recovery and reuse, and disposal of solid waste; implement a management program that

338

Woodstock Municipal Wind | Open Energy Information  

Open Energy Info (EERE)

Municipal Wind Municipal Wind Jump to: navigation, search Name Woodstock Municipal Wind Facility Woodstock Municipal Wind Sector Wind energy Facility Type Commercial Scale Wind Facility Status In Service Developer Juhl Wind Energy Purchaser Xcel Energy Location Woodstock MN Coordinates 44.009957°, -96.100552° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":44.009957,"lon":-96.100552,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

339

New London Municipal Utilities | Open Energy Information  

Open Energy Info (EERE)

New London Municipal Utilities New London Municipal Utilities Place Iowa Utility Id 13468 Utility Location Yes Ownership M NERC Location MRO Operates Generating Plant Yes Activity Generation Yes Activity Distribution Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png City All-Electric Residential Residential City Residential Residential General Service and Municipal Commercial Large General Service and Municipal (Demand) Commercial Rural Resident and Farm Residential Rural Resident and Farm All-Electric Residential Security Lights 100w HPS Metered light Lighting

340

River Falls Municipal Utilities - Business Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Will match Focus on Energy incentive to 5,000 Commercial Central AC Tune-Up: 50 LED Exit Signs: Free Installation River Falls Municipal Utility (RFMU) offers a variety of...

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Sacramento Municipal Utility District | Open Energy Information  

Open Energy Info (EERE)

Municipal Utility District Municipal Utility District (Redirected from Sacramento Municipal Utility District (SMUD)) Jump to: navigation, search Name Sacramento Municipal Util Dist Place Sacramento, California Website www.smud.org Utility Id 16534 Utility Location Yes Ownership P NERC Location WECC NERC WECC Yes ISO CA Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] Energy Information Administration Form 826[2] SGIC[3] Information About Partnership with NREL Partnership with NREL Yes Partnership Type Test & Evaluation Partner Partnering Center within NREL Electricity Resources & Building Systems Integration

342

Gowrie Municipal Utilities | Open Energy Information  

Open Energy Info (EERE)

Gowrie Municipal Utilities Gowrie Municipal Utilities Jump to: navigation, search Name Gowrie Municipal Utilities Place Iowa Utility Id 7424 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes ISO MISO Yes Operates Generating Plant Yes Activity Generation Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Commercial Residential Residential Average Rates Residential: $0.0976/kWh Commercial: $0.0900/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Gowrie_Municipal_Utilities&oldid=41075

343

Lawrenceburg Municipal Utils | Open Energy Information  

Open Energy Info (EERE)

Lawrenceburg Municipal Utils Lawrenceburg Municipal Utils Jump to: navigation, search Name Lawrenceburg Municipal Utils Place Indiana Utility Id 10798 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes ISO MISO Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates Residential: $0.0749/kWh Commercial: $0.1150/kWh Industrial: $0.0597/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Lawrenceburg_Municipal_Utils&oldid=410978

344

Minnesota Municipal Power Agency | Open Energy Information  

Open Energy Info (EERE)

(Redirected from Minnesota Municipal Power Agny) (Redirected from Minnesota Municipal Power Agny) Jump to: navigation, search Name Minnesota Municipal Power Agency Place Minnesota Utility Id 12667 Utility Location Yes Ownership A NERC Location MRO NERC MRO Yes ISO MISO Yes Operates Generating Plant Yes Activity Generation Yes Activity Buying Transmission Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Minnesota_Municipal_Power_Agency&oldid=412260

345

Texas Municipal Power Agency | Open Energy Information  

Open Energy Info (EERE)

Municipal Power Agency Municipal Power Agency Jump to: navigation, search Name Texas Municipal Power Agency Place Texas Utility Id 18715 Utility Location Yes Ownership M NERC Location TRE NERC ERCOT Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Texas_Municipal_Power_Agency&oldid=411659" Categories:

346

Hudson Municipal Electric Utility | Open Energy Information  

Open Energy Info (EERE)

Municipal Electric Utility Municipal Electric Utility Jump to: navigation, search Name Hudson Municipal Electric Utility Place Iowa Utility Id 8966 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Commercial Residential Residential Residential All-Electric Residential School Rate Commercial Average Rates Residential: $0.0993/kWh Commercial: $0.0905/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Hudson_Municipal_Electric_Utility&oldid=410846

347

Alameda Municipal Power- Solar Photovoltaics Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

'''''Note: Alameda Municipal Power had a budget of $4.2 million to support this program. The utility has allocated the full budget and is no longer accepting applications. The information below is...

348

Alameda Municipal Power- Residential Energy Efficiency Program  

Energy.gov (U.S. Department of Energy (DOE))

Alameda Municipal Power (AMP) has multiple program in place to help encourage its customers to adopt energy efficient equipment and practices in their homes.  The first of these initiatives is a...

349

CFD Simulation of Infiltration Heat Recovery  

E-Print Network (OSTI)

Nomenclature Cp= specific heat capacity of air (1006 J/kg K) CP,= specific heat capacity of insulation solidJ/kg K) CPW specific heat capacity of wall sheathing (1200

Buchanan, C.R.

2011-01-01T23:59:59.000Z

350

Solids irradiator  

DOE Patents (OSTI)

A novel facility for irradiation of solids embodying pathogens wherein solids are conveyed through an irradiation chamber in individual containers of an endless conveyor.

Morris, Marvin E. (Albuquerque, NM); Pierce, Jim D. (Albuquerque, NM); Whitfield, Willis J. (Albuquerque, NM)

1979-01-01T23:59:59.000Z

351

A generalized multistage optimization modeling framework for life cycle assessment-based integrated solid waste management  

Science Conference Proceedings (OSTI)

Solid waste management (SWM) is an integral component of civil infrastructure and the global economy, and is a growing concern due to increases in population, urbanization, and economic development. In 2011, 1.3 billion metric tons of municipal solid ... Keywords: Decision support, Life cycle assessment, Multi-stage, Optimization, Solid waste

James W. Levis, Morton A. Barlaz, Joseph F. Decarolis, S. Ranji Ranjithan

2013-12-01T23:59:59.000Z

352

Fuzzy parametric programming model for multi-objective integrated solid waste management under uncertainty  

Science Conference Proceedings (OSTI)

Solid waste management is increasingly becoming a challenging task for the municipal authorities due to increasing waste quantities, changing waste composition, decreasing land availability for waste disposal sites and increasing awareness about the ... Keywords: Fuzzy parametric programming, Integrated solid waste management system, Long term planning, Multi-objective and multi-period planning, Solid waste management

Amitabh Kumar Srivastava; Arvind K. Nema

2012-04-01T23:59:59.000Z

353

Municipal bond financing of solar energy facilities  

DOE Green Energy (OSTI)

The application of the laws of municipal bond financing to solar facilities is examined. The type of facilities under consideration are outlined. The general legal principles of municipal securities financing are discussed. The effect of recent decisions applying antitrust liability to municipal corporations is also discussed. Five specific types of municipal bonds are explained. The application of Section 103 of the Internal Revenue Code of 1954, as amended, to the issuance of municipal bonds for solar facility financing is examined also. Five bond laws of five representative states are examined and whether the eight types of solar facilities under consideration could be financed under such law is discussed. The application of the general legal principle is illustrated. Three hypothetical situations are set forth and common legal issues to be confronted by city officials in proposing such financing are discussed. These issues will be raised in most financings, but the purpose is to examine the common context in which they are raised. It is concluded that if it can be shown that the purpose of the solar facilities to be financed is to benefit the public, all legal obstacles to the use of municipal financing of solar facilities can be substantially overcome.

White, S.S.

1979-12-01T23:59:59.000Z

354

Spatial and Temporal Characteristics of Beijing Urban Heat Island Intensity  

Science Conference Proceedings (OSTI)

An hourly dataset of automatic weather stations over Beijing Municipality in China is developed and is employed to analyze the spatial and temporal characteristics of urban heat island intensity (UHII) over the built-up areas. A total of 56 ...

Ping Yang; Guoyu Ren; Weidong Liu

2013-08-01T23:59:59.000Z

355

Management of Solid Waste (Oklahoma) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Management of Solid Waste (Oklahoma) Management of Solid Waste (Oklahoma) Management of Solid Waste (Oklahoma) < Back Eligibility Utility Agricultural Investor-Owned Utility Industrial Municipal/Public Utility Rural Electric Cooperative Program Info State Oklahoma Program Type Environmental Regulations Provider Oklahoma Department of Environmental Quality The Solid Waste Management Division of the Department of Environmental Quality regulates solid waste disposal or any person who generates, collects, transports, processes, and/or disposes of solid waste and/or waste tires. The following solid waste disposal facilities require a solid waste permit prior to construction and/or operation: land disposal facilities; solid waste processing facilities, including: transfer stations; solid waste incinerators receiving waste from off-site sources; regulated medical waste

356

Comparison of slope stability in two Brazilian municipal landfills  

SciTech Connect

The implementation of landfill gas to energy (LFGTE) projects has greatly assisted in reducing the greenhouse gases and air pollutants, leading to an improved local air quality and reduced health risks. The majority of cities in developing countries still dispose of their municipal waste in uncontrolled 'open dumps.' Municipal solid waste landfill construction practices and operating procedures in these countries pose a challenge to implementation of LFGTE projects because of concern about damage to the gas collection infrastructure (horizontal headers and vertical wells) caused by minor, relatively shallow slumps and slides within the waste mass. While major slope failures can and have occurred, such failures in most cases have been shown to involve contributory factors or triggers such as high pore pressures, weak foundation soil or failure along weak geosynthetic interfaces. Many researchers who have studied waste mechanics propose that the shear strength of municipal waste is sufficient such that major deep-seated catastrophic failures under most circumstances require such contributory factors. Obviously, evaluation of such potential major failures requires expert analysis by geotechnical specialists with detailed site-specific information regarding foundation soils, interface shearing resistances and pore pressures both within the waste and in clayey barrier layers or foundation soils. The objective of this paper is to evaluate the potential use of very simple stability analyses which can be used to study the potential for slumps and slides within the waste mass and which may represent a significant constraint on construction and development of the landfill, on reclamation and closure and on the feasibility of a LFGTE project. The stability analyses rely on site-specific but simple estimates of the unit weight of waste and the pore pressure conditions and use 'generic' published shear strength envelopes for municipal waste. Application of the slope stability analysis method is presented in a case study of two Brazilian landfill sites; the Cruz das Almas Landfill in Maceio and the Muribeca Landfill in Recife. The Muribeca site has never recorded a slope failure and is much larger and better-maintained when compared to the Maceio site at which numerous minor slumps and slides have been observed. Conventional limit-equilibrium analysis was used to calculate factors of safety for stability of the landfill side slopes. Results indicate that the Muribeca site is more stable with computed factors of safety values in the range 1.6-2.4 compared with computed values ranging from 0.9 to 1.4 for the Maceio site at which slope failures have been known to occur. The results suggest that this approach may be useful as a screening-level tool when considering the feasibility of implementing LFGTE projects.

Gharabaghi, B. [School of Engineering, University of Guelph, Guelph, Ontario, N1G 2W1 (Canada)], E-mail: bgharaba@uoguelph.ca; Singh, M.K. [Department of Civil and Geological Engineering, University of Saskatchewan, Saskatoon, S7N 5A9 (Canada); Inkratas, C. [School of Engineering, University of Guelph, Guelph, Ontario, N1G 2W1 (Canada)], E-mail: cinkrata@uoguelph.ca; Fleming, I.R. [Department of Civil and Geological Engineering, University of Saskatchewan, Saskatoon, S7N 5A9 (Canada)], E-mail: ian.fleming@usask.ca; McBean, E. [School of Engineering, University of Guelph, Guelph, Ontario, N1G 2W1 (Canada)], E-mail: emcbean@uoguelph.ca

2008-07-01T23:59:59.000Z

357

Municipal performance: does mayoral quality matter?  

E-Print Network (OSTI)

This research addresses the question of what explains municipal performance in terms of delivering social services and fiscal performance. While the existing literature explains governmental performance with political, institutional and socio-demographic factors, I suggest that the greatest influence on municipal performance comes from having qualified managers. Specifically, I argue that that mayoral qualifications influence municipal performance. By qualifications I mean mayors’ human capital, that is, their educational and job-related experience. The rationale for my proposition rests on the fact that in developing municipalities the mayor is not just the elected leader but also the public manager, as s/he performs not just political but also administrative functions. Under certain circumstances, however, mayoral qualifications may not have the same influential power on municipal performance. Therefore, I also argue that in unfavorable municipal contexts, the potential influence of mayoral qualifications on performance decreases. I use both statistical and survey-experimental methodologies to test the hypotheses derived from the proposed “mayoral quality theory.” I collected six years of data for the statistical analyses by doing field research across the 40 municipalities that comprise the Colombian Department of Norte of Santander. For the surveyexperimental analysis, I gathered data from interviews and surveys with 120 mayors from 12 Latin American countries, who participated in the II Latin American Congress of Cities and Local Governments held in Cali, Colombia, on July 26-29, 2006. The statistical findings reveal that mayoral qualifications—education and jobrelated experience—positively influence municipal performance with respect to education enrollment, tax property collection, and social program investment. However, the positive impact that mayoral qualifications have on such performance indicators decreases under external constraints, such as the presence of illegal armed groups. From the survey-experimental study, findings show that issue salience (or nature of municipal need) moderates the impact that mayoral qualifications have on mayors’ decision-making. In education issues, for example, qualified mayors are more likely to perform better, while in infrastructure issues they are less likely to do so.

Avellaneda, Claudia Nancy

2007-12-01T23:59:59.000Z

358

Chapter 47 Solid Waste Facilities (Kentucky) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Chapter 47 Solid Waste Facilities (Kentucky) Chapter 47 Solid Waste Facilities (Kentucky) Chapter 47 Solid Waste Facilities (Kentucky) < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Program Info State Kentucky Program Type Environmental Regulations Fees Siting and Permitting Provider Kentucky Division of Waste Management This chapter establishes the permitting standards for solid waste sites or facilities, the standards applicable to all solid waste sites or

359

Modeling of Heat Transfer in Rooms in the Modelica Buildings Library  

E-Print Network (OSTI)

for one-dimensional heat conduction in a solid only needs todifferent models to compute heat conduction through opaqueone-dimensional heat conduction through multi-layered

Wetter, Michael

2013-01-01T23:59:59.000Z

360

Trenton Municipal Utilities | Open Energy Information  

Open Energy Info (EERE)

Trenton Municipal Utilities Trenton Municipal Utilities Jump to: navigation, search Name Trenton Municipal Utilities Place Missouri Utility Id 19150 Utility Location Yes Ownership M NERC Location SPP NERC SPP Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Church Rate Commercial Commercial All Electric Rate Commercial Commercial General Electric Rate Commercial Commercial Power Rate Commercial Grundy Electric Rate for City Line Usage Commercial

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Philippi Municipal Electric | Open Energy Information  

Open Energy Info (EERE)

Philippi Municipal Electric Philippi Municipal Electric Place West Virginia Utility Id 14954 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Economic Development Rate Industrial General Service Commercial Large Power Commercial Outdoor Lighting- 175W High Pressure Sodium Lighting Residential Residential Average Rates Residential: $0.0904/kWh Commercial: $0.0800/kWh Industrial: $0.0976/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Philippi_Municipal_Electric&oldid=411361

362

Rancho Cucamonga Municipal Utility | Open Energy Information  

Open Energy Info (EERE)

Rancho Cucamonga Municipal Utility Rancho Cucamonga Municipal Utility Jump to: navigation, search Name Rancho Cucamonga Municipal Utility Place California Utility Id 56224 Utility Location Yes Ownership M NERC WECC Yes ISO CA Yes Activity Distribution Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Irrigation Systems Commercial Large Commercial Commercial Medium Commercial Commercial Medium Commercial (Time-Of-Use) Commercial Net Energy Metering Commercial Outdoor Area Lighting Lighting Small Comercial Commercial Small Commercial Three Phase Commercial

363

Wyoming Municipal Power Agency | Open Energy Information  

Open Energy Info (EERE)

Wyoming Municipal Power Agency Wyoming Municipal Power Agency Place Wyoming Utility Id 40603 Utility Location Yes Ownership A NERC Location WECC NERC WECC Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Wyoming_Municipal_Power_Agency&oldid=412214

364

Mohawk Municipal Comm | Open Energy Information  

Open Energy Info (EERE)

Municipal Comm Municipal Comm Jump to: navigation, search Name Mohawk Municipal Comm Place New York Utility Id 12759 Utility Location Yes Ownership M NERC Location NPCC Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Industrial Rate Industrial Large Commercial Commercial Public Street Lighting Lighting Security Lighting 150 w lamp Lighting Security Lighting 175 w lamp Lighting Security Lighting 250 w lamp Lighting Security Lighting 400 w lamp Lighting Single-Phase Residential Residential Small Commercial Business Commercial Average Rates Residential: $0.0366/kWh

365

Lassen Municipal Utility District | Open Energy Information  

Open Energy Info (EERE)

Municipal Utility District Municipal Utility District Jump to: navigation, search Name Lassen Municipal Utility District Place California Utility Id 10724 Utility Location Yes Ownership M NERC Location WECC NERC WECC Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Agricultural Pumping Commercial Domestic Residential General Service (Non-Demand) Commercial General Service Metered Demand Commercial Industrial Industrial Outdoor Area Lighting 100W Lighting Outdoor Area Lighting 200W Lighting Standby Reactive Rate Commercial Average Rates

366

Canton Municipal Utilities | Open Energy Information  

Open Energy Info (EERE)

Canton Municipal Utilities Canton Municipal Utilities Jump to: navigation, search Name Canton Municipal Utilities Place Mississippi Utility Id 2974 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes Operates Generating Plant Yes Activity Generation Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png E01 RESIDENTIAL ALL ELECTRIC Residential E04 COMMERCIAL ELECTRIC Commercial E08 LARGE INDUSTRIAL ELECTRIC Industrial E09 RESIDENTIAL ELECTRIC Residential E12 SMALL INDUSTRIAL ELECTRIC Industrial E13 ELECTRIC WATER HEATER Commercial Average Rates Residential: $0.0978/kWh

367

Delano Municipal Utilities | Open Energy Information  

Open Energy Info (EERE)

Municipal Utilities Municipal Utilities Jump to: navigation, search Name Delano Municipal Utilities Place Minnesota Utility Id 5015 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes ISO MISO Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commerical Rate Commercial Industrial Rate Industrial Residential Rate Residential Average Rates Residential: $0.1060/kWh Commercial: $0.0995/kWh Industrial: $0.0854/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a"

368

Illinois Municipal Elec Agency | Open Energy Information  

Open Energy Info (EERE)

Illinois Municipal Elec Agency Illinois Municipal Elec Agency Place Illinois Utility Id 9286 Utility Location Yes Ownership A NERC Location RFC & SERC NERC RFC Yes NERC SERC Yes Operates Generating Plant Yes Activity Generation Yes Activity Buying Transmission Yes Activity Buying Distribution Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Illinois_Municipal_Elec_Agency&oldid=410862

369

Bancroft Municipal Utilities | Open Energy Information  

Open Energy Info (EERE)

Bancroft Municipal Utilities Bancroft Municipal Utilities Jump to: navigation, search Name Bancroft Municipal Utilities Place Iowa Utility Id 1172 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes Operates Generating Plant Yes Activity Generation Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Demand Rates Commercial Schedule 1 Residential Schedule 2 Commercial Schedule 3 Residential Average Rates Residential: $0.1020/kWh Commercial: $0.0990/kWh Industrial: $0.0932/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a"

370

Tipton Municipal Electric Util | Open Energy Information  

Open Energy Info (EERE)

Tipton Municipal Electric Util Tipton Municipal Electric Util Jump to: navigation, search Name Tipton Municipal Electric Util Place Indiana Utility Id 18942 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Rate A- Residential Electric Service Residential Rate B- Commercial Electric Service Commercial Rate C- General and Industrial Power Service, Single Phase Industrial Rate C- General and Industrial Power Service, Three Phase Industrial Rate CG- Cogeneration Commercial Rate D- Primary Power and Lighting Service

371

Thurmont Municipal Light Co | Open Energy Information  

Open Energy Info (EERE)

Thurmont Municipal Light Co Thurmont Municipal Light Co Jump to: navigation, search Name Thurmont Municipal Light Co Place Maryland Utility Id 18901 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png LARGE GENERAL SERVICE Primary Voltage Industrial LARGE GENERAL SERVICE Secondary Voltage Industrial MEDIUM GENERAL SERVICE Industrial OUTDOOR LIGHTING SERVICE(11,000) Lighting OUTDOOR LIGHTING SERVICE(20,000) Lighting OUTDOOR LIGHTING SERVICE(400w) Lighting OUTDOOR LIGHTING SERVICE(7,000) Lighting RESIDENTIAL SERVICE Residential

372

Cascade Municipal Utilities | Open Energy Information  

Open Energy Info (EERE)

Cascade Municipal Utilities Cascade Municipal Utilities Jump to: navigation, search Name Cascade Municipal Utilities Place Iowa Utility Id 3137 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes ISO MISO Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png All Electric Rate Residential City/Interdept. Rate Commercial Commercial Rate 3-phase Commercial Commercial Rate Single-phase Commercial Demand Rate Industrial Residential Rates Residential Average Rates Residential: $0.1040/kWh

373

Chillicothe Municipal Utils | Open Energy Information  

Open Energy Info (EERE)

Chillicothe Municipal Utils Chillicothe Municipal Utils Jump to: navigation, search Name Chillicothe Municipal Utils Place Missouri Utility Id 3486 Utility Location Yes Ownership M NERC Location SPP NERC SPP Yes Operates Generating Plant Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png COMMERCIAL (NON DEMAND)SERVICE SCHEDULE - CO Commercial LARGE COMMERCIAL SERVICE SCHEDULE - LP Commercial LARGE INDUSTRIAL SERVICE SCHEDULE - LI-01 Industrial RESIDENTIAL SERVICE SCHEDULE Residential SMALL INDUSTRIAL (NON DEMAND) SERVICE SCHEDULE - CO-06 Industrial Average Rates

374

Kenyon Municipal Utilities | Open Energy Information  

Open Energy Info (EERE)

Kenyon Municipal Utilities Kenyon Municipal Utilities Jump to: navigation, search Name Kenyon Municipal Utilities Place Minnesota Utility Id 10179 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes Operates Generating Plant Yes Activity Generation Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Service Rate Commercial Large Commercial/Demand Service Rate Commercial Residential Service Rate Residential Security Lights Lighting Street Lights Lighting Average Rates Residential: $0.1200/kWh Commercial: $0.1100/kWh

375

Winner Municipal Utility | Open Energy Information  

Open Energy Info (EERE)

Winner Municipal Utility Winner Municipal Utility Jump to: navigation, search Name Winner Municipal Utility Place South Dakota Utility Id 20823 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Large Commercial Rate Commercial Mutiple Dwelling Rate Residential Residential Rate Residential Security Lighting Rate Lighting Small Commercial Rate Commercial Average Rates Residential: $0.0929/kWh Commercial: $0.0845/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from

376

Rock Rapids Municipal Utility | Open Energy Information  

Open Energy Info (EERE)

Rapids Municipal Utility Rapids Municipal Utility Jump to: navigation, search Name Rock Rapids Municipal Utility Place Iowa Utility Id 16206 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Power (Single-Phase) Commercial Commercial Power (Three-Phase) Commercial Residential Power Residential Average Rates Residential: $0.0807/kWh Commercial: $0.0633/kWh Industrial: $0.0899/kWh

377

Albertville Municipal Utils Bd | Open Energy Information  

Open Energy Info (EERE)

Albertville Municipal Utils Bd Albertville Municipal Utils Bd Jump to: navigation, search Name Albertville Municipal Utils Bd Place Alabama Utility Id 241 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png General Power Rate - SGSC Commercial General Power Rate - SGSD Industrial General Power Rate(Schedule GSA)-Part 1 Commercial General Power Rate(Schedule GSA)-Part 2 Commercial General Power Rate(Schedule GSA)-Part 3 Commercial Manufacturing Service Rate - SMSB Industrial Manufacturing Service Rate - SMSC Industrial

378

Madisonville Municipal Utils | Open Energy Information  

Open Energy Info (EERE)

Madisonville Municipal Utils Madisonville Municipal Utils Jump to: navigation, search Name Madisonville Municipal Utils Place Kentucky Utility Id 11488 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Electric Service-less than 50 KW Commercial Demand Commercial Electric Service-50 KW per month or more Commercial Residential Electric Service Residential Security Lights Overhead Flood Light HPS 400 W Lighting Security Lights Overhead Flood Light MH 400 W Lighting Security Lights Overhead HPS 150 W Lighting

379

Price Municipal Corporation | Open Energy Information  

Open Energy Info (EERE)

Municipal Corporation Municipal Corporation Jump to: navigation, search Name Price Municipal Corporation Place Utah Utility Id 14198 Utility Location Yes Ownership M NERC Location WECC NERC WECC Yes Activity Distribution Yes Activity Buying Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Electrical substation delivery discount Commercial General Service- Large Industrial General service-small Industrial Residential Residential Security area lighting-250 watts and up Lighting Security area lighting-Less than 250 watts Lighting Special service-Non profit charitable organization Commercial

380

Rochelle Municipal Utilities | Open Energy Information  

Open Energy Info (EERE)

Municipal Utilities Municipal Utilities Jump to: navigation, search Name Rochelle Municipal Utilities Place Illinois Utility Id 16179 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Buying Distribution Yes Activity Wholesale Marketing Yes Activity Retail Marketing Yes Activity Bundled Services Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Large General Service Commercial Large General Service Time of Day Commercial

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Edinburg Municipal Utilities | Open Energy Information  

Open Energy Info (EERE)

Edinburg Municipal Utilities Edinburg Municipal Utilities Jump to: navigation, search Name Edinburg Municipal Utilities Place Indiana Utility Id 5655 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png All Electric Residential and Farm Residential Electric Commercial Commercial Electric General Power Industrial Industrial Power(Transformer capacity Greater than 999kVA) Industrial Residential Residential Rural Commercial Commercial Rural Residential and Farm Residential Average Rates Residential: $0.0912/kWh

382

Indiana Municipal Power Agency | Open Energy Information  

Open Energy Info (EERE)

Municipal Power Agency Municipal Power Agency Place Indiana Utility Id 9234 Utility Location Yes Ownership A NERC Location RFC NERC RFC Yes RTO PJM Yes ISO MISO Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Indiana_Municipal_Power_Agency&oldid=41086

383

North Branch Municipal Water & Light- Residential Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Southern Minnesota Municipal Power Agency ([http://www.smmpa.com SMMPA]) is a joint-action agency which generates and sells reliable electricity at wholesale to its eighteen non-profit, municipally...

384

Modelling transient heat conduction in solids at multiple length and time scales: A coupled non-equilibrium molecular dynamics/continuum approach  

SciTech Connect

A method for controlling the thermal boundary conditions of non-equilibrium molecular dynamics simulations is presented. The method is simple to implement into a conventional molecular dynamics code and independent of the atomistic model employed. It works by regulating the temperature in a thermostatted boundary region by feedback control to achieve the desired temperature at the edge of an inner region where the true atomistic dynamics are retained. This is necessary to avoid intrinsic boundary effects in non-equilibrium molecular dynamics simulations. Three thermostats are investigated: the global deterministic Nose-Hoover thermostat and two local stochastic thermostats, Langevin and stadium damping. The latter thermostat is introduced to avoid the adverse reflection of phonons that occurs at an abrupt interface. The method is then extended to allow atomistic/continuum models to be thermally coupled concurrently for the analysis of large steady state and transient heat conduction problems. The effectiveness of the algorithm is demonstrated for the example of heat flow down a three-dimensional atomistic rod of uniform cross-section subjected to a variety of boundary conditions.

Jolley, Kenny [Department of Engineering, University of Leicester, University Road, Leicester LE1 7RH (United Kingdom); Gill, Simon P.A. [Department of Engineering, University of Leicester, University Road, Leicester LE1 7RH (United Kingdom)], E-mail: spg3@le.ac.uk

2009-10-20T23:59:59.000Z

385

A new way to stabilize fly ash from municipal incinerators  

Science Conference Proceedings (OSTI)

Heavy metals and toxic chlorinated organics, added to very low grain-size distributions, make fly ashes from municipal incinerators a very hazardous waste. For their disposal, the present general trend is, not only to stabilize chemically the ashes, i.e., to reduce the leachability of the toxic substances, but also to stabilize them mechanically, i.e., to convert them into massive, resistant, and unleachable solids. This paper describes various stabilization methods used on representative European fly ash samples, which led to the development of a new stabilization technique taking place in four stages: elimination of the alkali chlorides by dissolution; addition of a moderate quantity of phosphoric acid; calcination; and solidification with Portland clinker or cement. The principal advantages of the process are as follows: the polychlorodibenzodioxins-polychlorodibenzofurans are destroyed, the reactivity of the heavy metals is reduced drastically, the final solids have satisfactory mechanical properties, and the increase in weight of the waste to be disposed of does not exceed one fourth. Comparative results of TCLP extraction tests are presented.

Derie, R. [Free Univ. of Brussels (Belgium). Dept. of Ore Dressing

1996-12-31T23:59:59.000Z

386

Solar solids reactor  

DOE Patents (OSTI)

A solar powered kiln is provided, that is of relatively simple design and which efficiently uses solar energy. The kiln or solids reactor includes a stationary chamber with a rearward end which receives solid material to be reacted and a forward end through which reacted material is disposed of, and a screw conveyor extending along the bottom of the chamber for slowly advancing the material between the chamber ends. Concentrated solar energy is directed to an aperture at the forward end of the chamber to heat the solid material moving along the bottom of the chamber. The solar energy can be reflected from a mirror facing at an upward incline, through the aperture and against a heat-absorbing material near the top of the chamber, which moves towards the rear of the chamber to distribute heat throughout the chamber. Pumps at the forward and rearward ends of the chamber pump heated sweep gas through the length of the chamber, while minimizing the flow of gas through an open aperture through which concentrated sunlight is received.

Yudow, Bernard D. (Chicago, IL)

1987-01-01T23:59:59.000Z

387

Computationally Optimized Homogenization Heat Treatment of Metal Alloys  

? A computational approach has been developed to improve the homogenization heat treatment of solid substitutional alloys. The method utilizes ...

388

Integrated solid waste management of Minneapolis, Minnesota  

Science Conference Proceedings (OSTI)

The subject document reports the results of an in-depth investigation of the fiscal year 1992 cost of the City of Minneapolis, Minnesota (Hennepin County) integrated municipal solid waste management (IMSWM) system, the energy consumed to operate the system, and the environmental performance requirements for each of the system`s waste-processing and disposal facilities. Actual data from records kept by participants is reported in this document. Every effort was made to minimize the use of assumptions, and no attempt is made to interpret the data reported. Analytical approaches are documented so that interested analysts may perform manipulation or further analysis of the data. As such, the report is a reference document for municipal solid waste (MSW) management professionals who are interested in the actual costs and energy consumption for a one-year period, of an operating IMSWM system.

NONE

1995-11-01T23:59:59.000Z

389

Doing business with business: Municipal utility energy audits  

Science Conference Proceedings (OSTI)

This article is a review of the ways in which municipal utilities can use energy audits to identify the energy efficiency measures that are most effective for themselves and their customers. Two examples, Osage Municipal Utilities in Iowa and Sacramento Municipal Utility District in California, are used to illustrate the strategies that are most cost effective.

NONE

1995-12-01T23:59:59.000Z

390

Marblehead Municipal Light Department - Residential Energy Efficiency...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heating & Cooling Cooling Appliances & Electronics Heat Pumps Maximum Rebate Insulation: 1,600 Program Information Massachusetts Program Type Utility Rebate Program Rebate...

391

Solid Waste Management Act (Oklahoma) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

You are here You are here Home » Solid Waste Management Act (Oklahoma) Solid Waste Management Act (Oklahoma) < Back Eligibility Agricultural Commercial Construction Industrial Installer/Contractor Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Utility Program Info State Oklahoma Program Type Environmental Regulations Provider Oklahoma Department of Environmental Quality This Act establishes rules for the permitting, posting of security, construction, operation, closure, maintenance and remediation of solid waste disposal sites; disposal of solid waste in ways that are environmentally safe and sanitary, as well as economically feasible; submission of laboratory reports or analyses performed by certified laboratories for the purposes of compliance monitoring and testing and for

392

Solid Waste Facilities Regulations (Massachusetts) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solid Waste Facilities Regulations (Massachusetts) Solid Waste Facilities Regulations (Massachusetts) Solid Waste Facilities Regulations (Massachusetts) < Back Eligibility Agricultural Commercial Construction Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Program Info State Massachusetts Program Type Environmental Regulations Provider Department of Environmental Protection This chapter of the Massachusetts General Laws governs the operation of solid waste facilities. It seeks to encourage sustainable waste management

393

Solid Waste Disposal Facilities (Massachusetts) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solid Waste Disposal Facilities (Massachusetts) Solid Waste Disposal Facilities (Massachusetts) Solid Waste Disposal Facilities (Massachusetts) < Back Eligibility Agricultural Commercial Construction Fed. Government Fuel Distributor Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Municipal/Public Utility Rural Electric Cooperative State/Provincial Govt Transportation Tribal Government Utility Program Info State Massachusetts Program Type Siting and Permitting Provider Department of Environmental Protection These sections articulate rules for the maintenance and operation of solid waste disposal facilities, as well as site assignment procedures. Applications for site assignment will be reviewed by the Massachusetts Department of Environmental Protection as well as the Department of Public

394

Solid Waste Management (Connecticut) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Connecticut) Connecticut) Solid Waste Management (Connecticut) < Back Eligibility Agricultural Commercial Construction Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Program Info State Connecticut Program Type Siting and Permitting Provider Department of Energy and Environmental Protection Solid waste facilities operating in Connecticut must abide by these regulations, which describe requirements and procedures for issuing construction and operating permits; environmental considerations;

395

Solid Waste Policies (Iowa) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Policies (Iowa) Policies (Iowa) Solid Waste Policies (Iowa) < Back Eligibility Agricultural Commercial Fuel Distributor Industrial Investor-Owned Utility Local Government Municipal/Public Utility Rural Electric Cooperative Tribal Government Utility Program Info State Iowa Program Type Environmental Regulations Provider Iowa Department of Natural Resources This statute establishes the support of the state for alternative waste management practices that reduce the reliance upon land disposal and incorporate resource recovery. Cities and counties are required to establish and operate a comprehensive solid waste reduction program. These regulations discuss land application of processed wastes as well as requirements for sanitary landfills and for groundwater monitoring near land disposal sites

396

Solid Waste Management (Michigan) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Michigan) Michigan) Solid Waste Management (Michigan) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State Michigan Program Type Siting and Permitting Provider Department of Environmental Quality This Act encourages the Department of Environmental Quality and Health Department representatives to develop and encourage methods for disposing solid waste that are environmentally sound, that maximize the utilization

397

Cap May County Municipal Utilities Authority | Open Energy Information  

Open Energy Info (EERE)

Cap May County Municipal Utilities Authority Cap May County Municipal Utilities Authority Jump to: navigation, search Name Cap May County Municipal Utilities Authority Place Cape May Court House, New Jersey Zip 8210 Product The CMCMUA was created to design, construct and operate efficient wastewater treatment facilities. References Cap May County Municipal Utilities Authority[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Cap May County Municipal Utilities Authority is a company located in Cape May Court House, New Jersey . References ↑ "Cap May County Municipal Utilities Authority" Retrieved from "http://en.openei.org/w/index.php?title=Cap_May_County_Municipal_Utilities_Authority&oldid=343207"

398

Municipal Energy Plan Program (Ontario, Canada) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Municipal Energy Plan Program (Ontario, Canada) Municipal Energy Plan Program (Ontario, Canada) Municipal Energy Plan Program (Ontario, Canada) < Back Eligibility Municipal/Public Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Maximum Rebate 90,000 Program Info Expiration Date 11/29/2013 State Ontario Program Type Grant Program Rebate Amount 50 percent of eligible costs Ontario is supporting local energy planning by introducing the Municipal Energy Plan (MEP) program. The MEP program is designed to help municipalities better understand their local energy needs and conservation opportunities, set goals and develop implementation plans. A MEP takes an integrated approach to energy planning by aligning energy, infrastructure and land use planning. MEPs will help municipalities:

399

Valley Center Municipal Water District | Open Energy Information  

Open Energy Info (EERE)

Municipal Water District Municipal Water District Jump to: navigation, search Name Valley Center Municipal Water District Place Valley Center, California Zip 92082 Product VCMWD is the second largest water provider in San Diego County behind the City of San Diego. References Valley Center Municipal Water District[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Valley Center Municipal Water District is a company located in Valley Center, California . References ↑ "Valley Center Municipal Water District" Retrieved from "http://en.openei.org/w/index.php?title=Valley_Center_Municipal_Water_District&oldid=352717" Categories: Clean Energy Organizations Companies Organizations

400

Heat pipe array heat exchanger  

DOE Patents (OSTI)

A heat pipe arrangement for exchanging heat between two different temperature fluids. The heat pipe arrangement is in a ounterflow relationship to increase the efficiency of the coupling of the heat from a heat source to a heat sink.

Reimann, Robert C. (Lafayette, NY)

1987-08-25T23:59:59.000Z

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Capacity-to-Act in India's Solid Waste Management and Waste-to-  

E-Print Network (OSTI)

1 Capacity-to-Act in India's Solid Waste Management and Waste-to- Energy Industries Perinaz Bhada and disposal of garbage, or municipal solid waste, compounded by increasing consumption levels. Another serious of converting waste into different forms of energy. The process of using waste as a fuel source and converting

Columbia University

402

Oklahoma Municipal Power Auth | Open Energy Information  

Open Energy Info (EERE)

Auth Auth Jump to: navigation, search Name Oklahoma Municipal Power Auth Place Oklahoma Utility Id 14077 Utility Location Yes Ownership S NERC Location SPP NERC SPP Yes RTO SPP Yes Operates Generating Plant Yes Activity Generation Yes Activity Transmission Yes Activity Buying Transmission Yes Activity Wholesale Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png No rate schedules available. Average Rates No Rates Available References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=Oklahoma_Municipal_Power_Auth&oldid=411268

403

Shawano Municipal Utilities | Open Energy Information  

Open Energy Info (EERE)

Shawano Municipal Utilities Shawano Municipal Utilities Place Wisconsin Utility Id 17011 Utility Location Yes Ownership M NERC Location RFC NERC RFC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Field Lighting Service Lighting General Single Phase Commercial General Single Phase TOD Commercial General Single Phase TOD 2 Commercial General Single Phase TOD 3 Commercial General Three Phase Commercial General Three Phase TOD Commercial General Three Phase TOD 2 Commercial General Three Phase TOD 3 Commercial Industrial Time-of-day Industrial Interdepartmental Commercial

404

Solid-State Lighting: Retrofit Financial Analysis Tool  

NLE Websites -- All DOE Office Websites (Extended Search)

Market-Based Programs Printable Version Share this resource Send a link to Solid-State Lighting: Retrofit Financial Analysis Tool to someone by E-mail Share Solid-State Lighting: Retrofit Financial Analysis Tool on Facebook Tweet about Solid-State Lighting: Retrofit Financial Analysis Tool on Twitter Bookmark Solid-State Lighting: Retrofit Financial Analysis Tool on Google Bookmark Solid-State Lighting: Retrofit Financial Analysis Tool on Delicious Rank Solid-State Lighting: Retrofit Financial Analysis Tool on Digg Find More places to share Solid-State Lighting: Retrofit Financial Analysis Tool on AddThis.com... LED Lighting Facts CALiPER Program Standards Development Technical Information Network Gateway Demonstrations Municipal Consortium About the Consortium FAQs

405

Solid-State Lighting: CALiPER Program  

NLE Websites -- All DOE Office Websites (Extended Search)

Market-Based Programs Printable Version Share this resource Send a link to Solid-State Lighting: CALiPER Program to someone by E-mail Share Solid-State Lighting: CALiPER Program on Facebook Tweet about Solid-State Lighting: CALiPER Program on Twitter Bookmark Solid-State Lighting: CALiPER Program on Google Bookmark Solid-State Lighting: CALiPER Program on Delicious Rank Solid-State Lighting: CALiPER Program on Digg Find More places to share Solid-State Lighting: CALiPER Program on AddThis.com... LED Lighting Facts CALiPER Program About the Program FAQs Summary Reports Detailed Reports Benchmark Reports Exploratory Studies Testing Laboratories Standards Development Technical Information Network Gateway Demonstrations Municipal Consortium Design Competitions CALiPER Program

406

Solid-State Lighting: Market-Based Programs  

NLE Websites -- All DOE Office Websites (Extended Search)

Market-Based Programs Printable Version Share this resource Send a link to Solid-State Lighting: Market-Based Programs to someone by E-mail Share Solid-State Lighting: Market-Based Programs on Facebook Tweet about Solid-State Lighting: Market-Based Programs on Twitter Bookmark Solid-State Lighting: Market-Based Programs on Google Bookmark Solid-State Lighting: Market-Based Programs on Delicious Rank Solid-State Lighting: Market-Based Programs on Digg Find More places to share Solid-State Lighting: Market-Based Programs on AddThis.com... LED Lighting Facts CALiPER Program Standards Development Technical Information Network Gateway Demonstrations Municipal Consortium Design Competitions Market-Based Programs To facilitate successful market introduction of high-quality,

407

Solid-State Lighting: Adaptive Street Lighting Controls  

NLE Websites -- All DOE Office Websites (Extended Search)

Adaptive Street Lighting Adaptive Street Lighting Controls to someone by E-mail Share Solid-State Lighting: Adaptive Street Lighting Controls on Facebook Tweet about Solid-State Lighting: Adaptive Street Lighting Controls on Twitter Bookmark Solid-State Lighting: Adaptive Street Lighting Controls on Google Bookmark Solid-State Lighting: Adaptive Street Lighting Controls on Delicious Rank Solid-State Lighting: Adaptive Street Lighting Controls on Digg Find More places to share Solid-State Lighting: Adaptive Street Lighting Controls on AddThis.com... Conferences & Meetings Presentations Publications Webcasts Videos Tools Adaptive Street Lighting Controls This two-part DOE Municipal Solid-State Street Lighting Consortium webinar focused on LED street lighting equipped with adaptive control components.

408

AN EXPERIMENTAL AND THEORETICAL STUDY OF HEAT TRANSFER WITH COMBUSTION  

E-Print Network (OSTI)

Figure 7.6. Thin film heat transfer gauge. I I il j i II· Figure 2. 2. Thin 1m heat transfer gauge. 'l' :i t jt IIIII. MEASUREMENTS AND HEAT TRANSFER IN THE SOLID Experiments

Heperkan, Hasan A.

2013-01-01T23:59:59.000Z

409

Sodium heat engine electrical feedthrough  

DOE Patents (OSTI)

A thermoelectric generator device which converts heat energy to electrical energy is disclosed. An alkali metal is used with a solid electrolyte and a hermetically sealed feedthrough structure. 4 figs.

Weber, N.

1985-03-19T23:59:59.000Z

410

Technological analysis of options for generating electricity with solid waste fuel in the Bangkok metropolitan area  

SciTech Connect

A discussion of relatively current techniques for converting mixed municipal waste into electricity is presented. A brief review of the comparative capabilities of the relevant energy recovery systems is documented in this section. The discussion is focused on the principal system and technological strategies that would be best suited for the municipal solid waste recovery project in Thailand. Emphasis in the review was placed on mixed waste processing in a mass burning waterwalled system.

1985-09-01T23:59:59.000Z

411

Mandatory Green Power Option for Large Municipal Utilities | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Green Power Option for Large Municipal Utilities Green Power Option for Large Municipal Utilities Mandatory Green Power Option for Large Municipal Utilities < Back Eligibility Municipal Utility Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Wind Program Info State Colorado Program Type Mandatory Utility Green Power Option Provider Colorado Public Utilities Commission Municipal electric utilities serving more than 40,000 customers in Colorado must offer an optional green-power program that allows retail customers the choice of supporting emerging renewable technologies. This policy complements Colorado's renewable portfolio standard (RPS), which requires municipal utilities serving more than 40,000 customers to use renewable energy and energy recycling to account for 10% of retail sales by 2020.

412

A Municipal Official's Guide to Diesel Idling Reduction | Open Energy  

Open Energy Info (EERE)

A Municipal Official's Guide to Diesel Idling Reduction A Municipal Official's Guide to Diesel Idling Reduction Jump to: navigation, search Tool Summary LAUNCH TOOL Name: A Municipal Official's Guide to Diesel Idling Reduction Agency/Company /Organization: United States Environmental Protection Agency Partner: New York Planning Federation Sector: Climate, Energy Focus Area: Transportation Resource Type: Lessons learned/best practices Website: www.nyserda.org/publications/09-06GuidetoDieselIdlingReduction.pdf Language: English References: A Municipal Official's Guide to Diesel Idling Reduction[1] References ↑ "A Municipal Official's Guide to Diesel Idling Reduction" Retrieved from "http://en.openei.org/w/index.php?title=A_Municipal_Official%27s_Guide_to_Diesel_Idling_Reduction&oldid=390471"

413

Experiment 7: Heat Phase Changes  

E-Print Network (OSTI)

Experiment 7: Heat Phase Changes Matter has 4 phases or states: solid, liquid, gas, and plasma. This lab looks at the phase transitions from solid to liquid to gas. 1. Obtain the following materials: 600mL beaker of ice, thermometer, hot plate, timer. 2. Add a very small amount of water to the ice so

Peterson, Blake R.

414

Micropyrolyzer for chemical analysis of liquid and solid samples ...  

A micropyrolyzer has applications to pyrolysis, heated chemistry, and thermal desorption from liquid or solid samples. The micropyrolyzer can be fabricated from ...

415

Application of Computational Thermodynamics in Solid Oxide Fuel ...  

Science Conference Proceedings (OSTI)

... Heat Index Based on the Hot Metal Silicon Content and Temperature Prediction Model ... Mechanical Stability of Solid Oxide Fuel Cell (SOFC) Materials: A ...

416

Federal Energy Management Program: Outdoor Solid State Street...  

NLE Websites -- All DOE Office Websites (Extended Search)

& Structures Case Studies Resources Working Group Distributed Energy ResourcesCombined Heat & Power Resources Renewable Energy Outdoor Solid State Street and Roadway Lighting...

417

Federal Energy Management Program: Outdoor Solid State Lighting...  

NLE Websites -- All DOE Office Websites (Extended Search)

& Structures Case Studies Resources Working Group Distributed Energy ResourcesCombined Heat & Power Resources Renewable Energy Outdoor Solid State Lighting Resources Picture of...

418

Federal Energy Management Program: Outdoor Solid State Parking...  

NLE Websites -- All DOE Office Websites (Extended Search)

& Structures Case Studies Resources Working Group Distributed Energy ResourcesCombined Heat & Power Resources Renewable Energy Outdoor Solid State Parking Lot and Structure...

419

Business Energy Investment Tax Credit (ITC) (Federal) | Open...  

Open Energy Info (EERE)

Direct Use, Geothermal Electric, Geothermal Heat Pumps, Hydroelectric, Landfill Gas, Microturbines, Municipal Solid Waste, Ocean Thermal, Photovoltaics, Small...

420

Municipal Water Pollution Control (Minnesota) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Municipal Water Pollution Control (Minnesota) Municipal Water Pollution Control (Minnesota) Municipal Water Pollution Control (Minnesota) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State Minnesota Program Type Siting and Permitting This statute applies to a city, sanitary district, or other governmental subdivision or public corporation. The statute gives the Pollution Control Agency the authority to prepare and enforce a long-range plan pertaining to

Note: This page contains sample records for the topic "heat municipal solid" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Municipal Waste Planning, Recycling and Waste Reduction Act (Pennsylvania)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Municipal Waste Planning, Recycling and Waste Reduction Act Municipal Waste Planning, Recycling and Waste Reduction Act (Pennsylvania) Municipal Waste Planning, Recycling and Waste Reduction Act (Pennsylvania) < Back Eligibility Agricultural Commercial Construction Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Pennsylvania Program Type Environmental Regulations

422

Delivering energy services: the emerging role of California's municipal utilities  

SciTech Connect

The financial circumstances and energy service opportunities for California's municipal electric utilities are explored. The structure and financial operation of municipal utilities, including the new role of joint powers agency financing, are analyzed. The advantages which conservation and alternative energy resources can offer municipal utilities are discussed: reduced capital requirements, increased cash flow, oil displacement, improved air quality, reduced risk of large plant outages, and matching new capacity to uncertain load growth. Recommendations are presented for removing the existing barriers which discourage prospects for municipal utility energy service investments, such as wholesale rate design reflecting flat or declining block rates and high demand charges, control of bulk power transmission lines by investor-owned utilities, failure of federal power-marketing agencies to provide conservation incentives to their municipal utility customers, and tax credit provisions of the Crude Oil Windfall Profit Tax Act of 1980. Appendices include the municipal utilities' current resource plans, the history and process of the formation of new municipal utilities, and the energy service role of municipal agencies in cities which may not have municipal utilities.

Dawson, M.H.; Praul, C.G.; Marcus, W.B.

1982-11-01T23:59:59.000Z

423

Reading Municipal Light Department - Business Lighting Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Reading Municipal Light Department - Business Lighting Rebate Reading Municipal Light Department - Business Lighting Rebate Program Reading Municipal Light Department - Business Lighting Rebate Program < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Schools State Government Savings Category Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Commercial Customers: $10,000 per calendar year Municipal Customers: $15,000 per calendar year Program Info State Massachusetts Program Type Utility Rebate Program Rebate Amount T-8/T-5 Lamp with Electronic Ballasts: $11 - $35/fixture Interior High Output Lamp with Electronic Ballasts: $100/fixture De-lamping: $4 - $9/lamp Lighting Sensors: $20/sensor LED Exit Signs: $20/fixture Provider Incentive Programs

424

Environmental training for municipality officers in Bosnia and Herzegovina.  

E-Print Network (OSTI)

?? This is a study that aims to help create a better world. As big as it sounds, it is the truth. Every day municipality… (more)

Jonsson, Ĺsa

2010-01-01T23:59:59.000Z

425

Business Case for CNG in Municipal Fleets (Presentation)  

Science Conference Proceedings (OSTI)

Presentation about compressed natural gas in municipal fleets, assessing investment profitability, the VICE model, base-case scenarios, and pressing questions for fleet owners.

Johnson, C.

2010-07-27T23:59:59.000Z

426

Concord Municipal Light Plant - Solar Rebate Program | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

625kW AC Concord Municipal Light Plant (CMLP) offers rebates to customers who install solar photovoltaic (PV) systems that are designed to offset the customer's electrical...

427

Frisco - Municipal Green Building Program (Texas) | Open Energy...  

Open Energy Info (EERE)

Rules Regulations Policies Program Place Texas Name Frisco - Municipal Green Building Program Incentive Type Energy Standards for Public Buildings Applicable Sector Local...

428

State Clean Energy Policies Analysis: State, Utility, and Municipal...  

NLE Websites -- All DOE Office Websites (Extended Search)

Technical Report State Clean Energy Policies NRELTP-6A2-47376 Analysis: State, Utility, and May 2010 Municipal Loan Programs Eric Lantz Technical Report State Clean Energy...

429

Concord Municipal Light Plant - Solar Rebate Program | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Light Plant Concord Municipal Light Plant (CMLP) offers rebates to customers who install solar photovoltaic (PV) systems that are designed to offset the customer's electrical...

430

American Municipal Power (Public Electric Utilities)- Commercial Efficiency Smart Program  

Energy.gov (U.S. Department of Energy (DOE))

Efficiency Smart™ provides energy efficiency incentives and technical assistance to the American Municipal Power, Inc (AMP) network of public power communities. The Efficiency Smart service...

431

Concord Municipal Light Plant- Residential Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Concord Municipal Light Plant (CMLP) offers its residential customers rebates on energy-efficient appliances through the Appliance Rebate Program. Rebates are available for Energy Star...

432

American Municipal Power (Public Electric Utilities)- Residential Efficiency Smart Program  

Energy.gov (U.S. Department of Energy (DOE))

Efficiency Smart ™ provides energy efficiency incentives to the American Municipal Power, Inc (AMP) network of public power communities. Efficiency Smart assists residential, commercial , and...

433

RECIPIENT:Hull Municipal Light Plant STATE: MA PROJECT TITLE...  

NLE Websites -- All DOE Office Websites (Extended Search)

Page 1 01 :L RECIPIENT:Hull Municipal Light Plant STATE: MA PROJECT TITLE: Hull Offshore Wind Research and Development Funding Opportunity Announcement Number Procurement...

434

Heat pipe heat amplifier  

SciTech Connect

In a heat pipe combination consisting of a common condenser section with evaporator sections at either end, two working fluids of different vapor pressures are employed to effectively form two heat pipe sections within the same cavity to support an amplifier mode of operation.

Arcella, F.G.

1978-08-15T23:59:59.000Z

435

Hazardous and Nonhazardous Solid Waste Applicant Disclosure Regulations  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Hazardous and Nonhazardous Solid Waste Applicant Disclosure Hazardous and Nonhazardous Solid Waste Applicant Disclosure Regulations (Mississippi) Hazardous and Nonhazardous Solid Waste Applicant Disclosure Regulations (Mississippi) < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Mississippi Program Type

436

Nonhazardous Solid Waste Management Regulations and Criteria (Mississippi)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Nonhazardous Solid Waste Management Regulations and Criteria Nonhazardous Solid Waste Management Regulations and Criteria (Mississippi) Nonhazardous Solid Waste Management Regulations and Criteria (Mississippi) < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Mississippi Program Type Environmental Regulations

437

Solid Waste Management Act (West Virginia) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Act (West Virginia) Act (West Virginia) Solid Waste Management Act (West Virginia) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State West Virginia Program Type Siting and Permitting Provider Department of Environmental Protection In addition to establishing a comprehensive program of controlling all phases of solid waste management and assigning responsibilities for solid waste management to the Secretary of Department of Environmental

438

Industrial Solid Waste Landfill Facilities (Ohio) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Industrial Solid Waste Landfill Facilities (Ohio) Industrial Solid Waste Landfill Facilities (Ohio) Industrial Solid Waste Landfill Facilities (Ohio) < Back Eligibility Agricultural Industrial Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative State/Provincial Govt Utility Program Info State Ohio Program Type Environmental Regulations Provider Ohio Environmental Protection Agency This chapter of the law establishes that the Ohio Environmental Protection Agency provides rules and guidelines for landfills, including those that treat waste to generate electricity. The law provides information for permitting, installing, maintaining, monitoring, and closing landfills. There are no special provisions or exemptions for landfills used to generate electricity. However, the law does apply to landfills that do

439

Gaines County Solid Waste Management Act (Texas) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Gaines County Solid Waste Management Act (Texas) Gaines County Solid Waste Management Act (Texas) Gaines County Solid Waste Management Act (Texas) < Back Eligibility Commercial Construction Industrial Investor-Owned Utility Local Government Municipal/Public Utility Rural Electric Cooperative Tribal Government Utility Program Info State Texas Program Type Environmental Regulations Provider Gaines County Solid Waste Management District This Act establishes the Gaines County Solid Waste Management District, a governmental body to develop and carry out a regional water quality protection program through solid waste management and regulation of waste disposal. The District has the power to prepare, adopt plans for, purchase, obtain permits for, construct, acquire, own, operate, maintain, repair, improve, and extend inside and outside the boundaries of the district any works,

440

Land application systems for municipal sludge  

SciTech Connect

The production of treated municipal sludge requiring disposal or recycling has increased substantially in the last 10 years as a result of more stringent waste-water treatment requirements. In 1974, for example, there were 3.2 million dry tons of sludge requiring disposal. By 1982 that number had more than doubled to 6.5 million dry tons/year. Land application of municipal sludge is widely practiced in the United States as a method of handling these increasing tonnages. For wastewater treatment plants with less than 10 mgd capacity, 39 percent of the sludge produced is managed by land application. Currently, for all size treatment plants, about 25 percent of the nation's sludge is land applied. The experience with land application has shown it to be a safe and effective sludge management practice. In particular, research and studies of the practice over the past 10 years have produced new knowledge which allows the benefits of land application to be realized with minimal adverse impact. 11 references.