Powered by Deep Web Technologies
Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Cost Benefit Analysis Modeling Tool for Electric vs. ICE Airport Ground Support Equipment – Development and Results  

SciTech Connect

This report documents efforts to develop a computer tool for modeling the economic payback for comparative airport ground support equipment (GSE) that are propelled by either electric motors or gasoline and diesel engines. The types of GSE modeled are pushback tractors, baggage tractors, and belt loaders. The GSE modeling tool includes an emissions module that estimates the amount of tailpipe emissions saved by replacing internal combustion engine GSE with electric GSE. This report contains modeling assumptions, methodology, a user’s manual, and modeling results. The model was developed based on the operations of two airlines at four United States airports.

James Francfort; Kevin Morrow; Dimitri Hochard

2007-02-01T23:59:59.000Z

2

Electric Ground Support Equipment Advanced Battery Technology Demonstration Project at the Ontario Airport  

SciTech Connect

The intent of the electric Ground Support Equipment (eGSE) demonstration is to evaluate the day-to-day vehicle performance of electric baggage tractors using two advanced battery technologies to demonstrate possible replacements for the flooded lead-acid (FLA) batteries utilized throughout the industry. These advanced battery technologies have the potential to resolve barriers to the widespread adoption of eGSE deployment. Validation testing had not previously been performed within fleet operations to determine if the performance of current advanced batteries is sufficient to withstand the duty cycle of electric baggage tractors. This report summarizes the work performed and data accumulated during this demonstration in an effort to validate the capabilities of advanced battery technologies. This report summarizes the work performed and data accumulated during this demonstration in an effort to validate the capabilities of advanced battery technologies. The demonstration project also grew the relationship with Southwest Airlines (SWA), our demonstration partner at Ontario International Airport (ONT), located in Ontario, California. The results of this study have encouraged a proposal for a future demonstration project with SWA.

Tyler Gray; Jeremy Diez; Jeffrey Wishart; James Francfort

2013-07-01T23:59:59.000Z

3

Research on Precise Support for Armored Equipment  

Science Conference Proceedings (OSTI)

The current support of the armored equipment is traditional extensive mode. There are many problems, such as excessive maintenance, late maintenance and high ratio of expenses to battle effectiveness. Aiming at these problems, the significance of Precise ... Keywords: Precise Support, Armored Equipment, advanced sensors, C4ISR

Yong-chun Xia; Yu-hua Zhou; Ren-jie Xu; Bi-wei Xie

2012-03-01T23:59:59.000Z

4

Interim Stabilization Equipment Essential and Support Drawing Plan  

Science Conference Proceedings (OSTI)

This supporting document provides a list of the Essential and Support drawings for the Interim Stabilization project equipment.

KOCH, M.R.

2000-01-14T23:59:59.000Z

5

Interim Stabilization Equipment Essential and Support Drawing Plan  

SciTech Connect

This supporting document provides a list of the Essential and Support drawings for the Interim Stabilization project equipment.

KOCH, M.R.

2000-01-28T23:59:59.000Z

6

Longevity of Emplacement Drift Ground Support Materials  

SciTech Connect

The purpose of this analysis is to evaluate the factors affecting the longevity of emplacement drift ground support materials and to develop a basis for selection of materials for ground support that will function throughout the preclosure period. The Development Plan (DP) for this analysis is given in CRWMS M&O (Civilian Radioactive Waste Management System Management and Operating Contractor) (1999a). The candidate materials for ground support are steel (carbon steel, ductile cast iron, galvanized steel, and stainless steel, etc.) and cement. Steel will mainly be used for steel sets, lagging, channels, rock bolts, and wire mesh. Cement usage is only considered in the case of grouted rock bolts. The candidate materials for the invert structure are steel and crushed rock ballast. The materials shall be evaluated for the repository emplacement drift environment under a specific thermal loading condition based on the proposed License Application Design Selection (LADS) design. The analysis consists of the following tasks: (1) Identify factors affecting the longevity of ground control materials for use in emplacement drifts. (2) Review existing documents concerning behavior of candidate ground control materials during the preclosure period. The major criteria to be considered for steel are mechanical and thermal properties, and durability, of which corrosion is the most important concern. (3) Evaluate the available results and develop recommendations for material(s) to be used.

D. Tang

2000-01-07T23:59:59.000Z

7

Increasing operational availability of H-60 calibration support equipment .  

E-Print Network (OSTI)

??The purpose of this MBA Project was to identify inefficiencies in the H-60 support equipment calibration process at Naval Air Station, North Island and analyze… (more)

Johnson, Kelly M.

2006-01-01T23:59:59.000Z

8

Longevity of Emplacement Drift Ground Support Materials  

Science Conference Proceedings (OSTI)

The purpose of this analysis is to evaluate the factors affecting the longevity of emplacement drift ground support materials and to develop a basis for the selection of materials for ground support that will function throughout the preclosure period of a potential repository at Yucca Mountain. REV 01 ICN 01 of this analysis is developed in accordance with AP-3.10Q, Analyses and Models, Revision 2, ICN 4, and prepared in accordance with the Technical Work Plan for Subsurface Design Section FY 01 Work Activities (CRWMS M&O 2001a). The objective of this analysis is to update the previous analysis (CRWMS M&O 2000a) to account for related changes in the Ground Control System Description Document (CRWMS M&O 2000b), the Monitored Geologic Repository Project Description Document, which is included in the Requirements and Criteria for Implementing a Repository Design that can be Operated Over a Range of Thermal Modes (BSC 2001), input information, and in environmental conditions, and to provide updated information on candidate ground support materials. Candidate materials for ground support are carbon steel and cement grout. Steel is mainly used for steel sets, lagging, channel, rock bolts, and wire mesh. Cement grout is only considered in the case of grouted rock bolts. Candidate materials for the emplacement drift invert are carbon steel and granular natural material. Materials are evaluated for the repository emplacement drift environment based on the updated thermal loading condition and waste package design. The analysis consists of the following tasks: (1) Identify factors affecting the longevity of ground support materials for use in emplacement drifts. (2) Review existing documents concerning the behavior of candidate ground support materials during the preclosure period. (3) Evaluate impacts of temperature and radiation effects on mechanical and thermal properties of steel. Assess corrosion potential of steel at emplacement drift environment. (4) Evaluate factors affecting longevity of cement grouts for fully grouted rock bolt system. Provide updated information on cement grout mix design for fully grouted rock bolt system. (5) Evaluate longevity of materials for the emplacement drift invert.

D.H.Tang

2001-05-30T23:59:59.000Z

9

ESF GROUND SUPPORT - STRUCTURAL STEEL ANALYSIS  

Science Conference Proceedings (OSTI)

The purpose and objective of this analysis are to expand the level of detail and confirm member sizes for steel sets included in the Ground Support Design Analysis, Reference 5.20. This analysis also provides bounding values and details and defines critical design attributes for alternative configurations of the steel set. One possible configuration for the steel set is presented. This analysis covers the steel set design for the Exploratory Studies Facility (ESF) entire Main Loop 25-foot diameter tunnel.

T. Misiak

1996-06-26T23:59:59.000Z

10

Interim Stabilization Equipment Essential and Support Drawing Plan  

SciTech Connect

The purpose of this document is to list the Interim Stabilization equipment drawings that are classified as Essential or Support drawings. Essential Drawings: Those drawings identified by the facility staff as necessary to directly support the safe operation of the facility or equipment. Support Drawings: Those drawings identified by the facility staff that further describe the design details of structures, systems or components shown on essential drawings.

KOCH, M.R.

1999-10-22T23:59:59.000Z

11

Interim Stabilization Equipment Essential and Support Drawing Plan  

Science Conference Proceedings (OSTI)

The purpose of this document is to list the Interim Stabilization equipment drawings that are classified as Essential or Support drawings. Essential Drawings are those drawings identified by the facility staff as necessary to directly support the safe operation of the facility or equipment. [CHG 2000a]. Support Drawings are those drawings identified by the facility staff that further describe the design details of structures, systems or components shown on essential drawings. [CHG 2000a].

HORNER, T.M.

2000-10-16T23:59:59.000Z

12

SLOPE STABILITY EVALUATION AND EQUIPMENT SETBACK DISTANCES FOR BURIAL GROUND EXCAVATIONS  

Science Conference Proceedings (OSTI)

After 1970 Transuranic (TRU) and suspect TRU waste was buried in the ground with the intention that at some later date the waste would be retrieved and processed into a configuration for long term storage. To retrieve this waste the soil must be removed (excavated). Sloping the bank of the excavation is the method used to keep the excavation from collapsing and to provide protection for workers retrieving the waste. The purpose of this paper is to document the minimum distance (setback) that equipment must stay from the edge of the excavation to maintain a stable slope. This evaluation examines the equipment setback distance by dividing the equipment into two categories, (1) equipment used for excavation and (2) equipment used for retrieval. The section on excavation equipment will also discuss techniques used for excavation including the process of benching. Calculations 122633-C-004, 'Slope Stability Analysis' (Attachment A), and 300013-C-001, 'Crane Stability Analysis' (Attachment B), have been prepared to support this evaluation. As shown in the calculations the soil has the following properties: Unit weight 110 pounds per cubic foot; and Friction Angle (natural angle of repose) 38{sup o} or 1.28 horizontal to 1 vertical. Setback distances are measured from the top edge of the slope to the wheels/tracks of the vehicles and heavy equipment being utilized. The computer program utilized in the calculation uses the center of the wheel or track load for the analysis and this difference is accounted for in this evaluation.

MCSHANE DS

2010-03-25T23:59:59.000Z

13

Heating and Cooling System Support Equipment Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Heating and Cooling System Support Equipment Basics Heating and Cooling System Support Equipment Basics Heating and Cooling System Support Equipment Basics July 30, 2013 - 3:28pm Addthis Thermostats and ducts provide opportunities for saving energy. Dehumidifying heat pipes provide a way to help central air conditioners and heat pumps dehumidify air. Electric and gas meters allow users to track energy use. Thermostats Programmable thermostats can store and repeat multiple daily settings. Users can adjust the times heating or air-conditioning is activated according to a pre-set schedule. Visit the Energy Saver website for more information about thermostats and control systems in homes. Ducts Efficient and well-designed duct systems distribute air properly throughout a building, without leaking, to keep all rooms at a comfortable

14

Standard guide for hot cell specialized support equipment and tools  

E-Print Network (OSTI)

1.1 Intent: 1.1.1 This guide presents practices and guidelines for the design and implementation of equipment and tools to assist assembly, disassembly, alignment, fastening, maintenance, or general handling of equipment in a hot cell. Operating in a remote hot cell environment significantly increases the difficulty and time required to perform a task compared to completing a similar task directly by hand. Successful specialized support equipment and tools minimize the required effort, reduce risks, and increase operating efficiencies. 1.2 Applicability: 1.2.1 This guide may apply to the design of specialized support equipment and tools anywhere it is remotely operated, maintained, and viewed through shielding windows or by other remote viewing systems. 1.2.2 Consideration should be given to the need for specialized support equipment and tools early in the design process. 1.2.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conv...

American Society for Testing and Materials. Philadelphia

2010-01-01T23:59:59.000Z

15

Appendix E Supporting Information for Ground Water Modeling  

Office of Legacy Management (LM)

Supporting Information for Ground Water Modeling Supporting Information for Ground Water Modeling This page intentionally left blank Contents Section Geologic Map of Site Area ........................................................................................................ E1.O Stream Flow Measurements ...................................................................................................... E2.0 Estimates of Ground Water Flow .............................................................................................. E3.0 .......................................... MODFLOW Flow Budget Analysis for OU 1 1 1 Model Subregions E4.0 ............................................................................ Burro Canyon Aquifer Ground Water Model E5.0 This page intentionally left blank

16

Advanced Vehicle Testing Activity - Electric Ground Support Equipment...  

NLE Websites -- All DOE Office Websites (Extended Search)

in the course of performing work sponsored by the U.S. Department of Energy's Advanced Vehicle Testing Activity, Electric Power Research Institute, Southern California Edison...

17

Longevity of Emplacement Drift Ground Support Materials, Rev. 01  

SciTech Connect

The purpose of this analysis is to evaluate the factors affecting the longevity of emplacement drift ground support materials and to develop a basis for the selection of materials for ground support that will function throughout the preclosure period of a potential repository at Yucca Mountain. The Development Plan (DP) for this analysis is given in Longevity of Emplacement Drift Ground Support Materials (CRWMS M&O 1999a). The objective of this analysis is to update the previous analysis (CRWMS M&O 2000a) to account for related changes in the Ground Control System Description Document (CRWMS M&O 2000b), the Monitored Geologic Repository Project Description Document (CRWMS M&O 1999b), and in environmental conditions, and to provide updated information on candidate ground support materials. Candidate materials for ground support are carbon steel and cement grout. Steel is mainly used for steel sets, lagging, channel, rock bolts, and wire mesh. Cement grout is only considered in the case of grouted rock bolts. Candidate materials for the emplacement drift invert are carbon steel and crushed rock ballast. Materials are evaluated for the repository emplacement drift environment based on the updated thermal loading condition and waste package design. The analysis consists of the following tasks: (1) Identify factors affecting the longevity of ground support materials for use in emplacement drifts; (2) Review existing documents concerning the behavior of candidate ground support materials during the preclosure period; (3) Evaluate impacts of temperature and radiation effects on mechanical and thermal properties of steel. Assess corrosion potential of steel at emplacement drift environment; (4) Evaluate factors affecting longevity of cement grouts for fully grouted rock bolt system. Provide updated information on cement grout mix design for fully grouted rock bolt system; and (5) Evaluate longevity of materials for the emplacement drift invert.

David H. Tang

2000-04-03T23:59:59.000Z

18

Blast-induced ground vibration prediction using support vector machine  

Science Conference Proceedings (OSTI)

Ground vibrations induced by blasting are one of the fundamental problems in the mining industry and may cause severe damage to structures and plants nearby. Therefore, a vibration control study plays an important role in the minimization of environmental ... Keywords: Blast vibration, Coefficient of determination, Conventional vibration predictor equations, Mean absolute error, Support vector machine

Manoj Khandelwal

2011-07-01T23:59:59.000Z

19

Laboratory Investigation into the Contribution of Contaminants to Ground Water from Equipment Materials Used in Sampling  

SciTech Connect

Benzene contamination was detected in well water samples from the Ogallala Aquifer beneath and adjacent to the Department of Energy's Pantex Plant near Amarillo, Texas. This study assessed whether or not the materials used in multilevel sampling equipment at this site could have contributed to the contaminants found in well water samples. As part of this investigation, laboratory testing of the sample equipment material was conducted. Results from the laboratory test indicated three different materials from two types of multilevel samplers did, in fact, contribute volatile and semivolatile organic compounds to the ground water samples from static leach tests that were conducted during an eight week period. The nylon-11 tubing contributed trace concentrations of benzene (1.37 ?g/L) and relatively high concentrations of the plasticizer N-butylbenzenesulfonamide (NBSA) (764 mg/L) to the water; a urethane-coated nylon well liner contributed relatively high concentrations of toluene (278 ?g/L) and trace amounts of NBSA; and a sampling port spacer material made of nylon/polypropylene/polyester-composite contributed trace amounts of toluene and NBSA. While the concentrations of benzene and toluene measured in the laboratory tests were below the concentrations measured in actual ground water samples, the concentrations of organics from these equipment materials were sufficient to render the results reported for the ground water samples suspect.

Gilmore, Tyler J.; Mitroshkov, Alexandre V.; Dresel, P Evan; Sklarew, Debbie S.

2004-08-30T23:59:59.000Z

20

Study of Support Amplification Factors for Various Frequency and Mass Ratios of Idealized Equipment Mounted on a Support Structure  

Science Conference Proceedings (OSTI)

This project studied the dynamic amplification factor of a support structure for various equipment–to–support mass and frequency ratios for cases in which utility substation equipment is mounted on a support structure and subject to IEEE standard 693, IEEE Recommended Practice for Seismic Design of Substations. The project is one of several sponsored by the Electric Power Research Institute (EPRI) Seismic Working Group, which was organized to conduct tests at appropriate ...

2013-06-26T23:59:59.000Z

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Equipment  

Science Conference Proceedings (OSTI)

...Manual gas cutting equipment consists of gas regulators, gas hoses, cutting torches, cutting tips, and multipurpose wrenches. Auxiliary equipment may include a hand truck, tip cleaners, torch ignitors, and protective goggles. Machine cutting

22

Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

Facility: Building 382 Rev. 1, 02/11/00 Facility: Building 382 Rev. 1, 02/11/00 Training: (1) ESH114 Lockout/Tagout ASD125 APS LOTO ESH371 Electrical Safety - General ESH195 PPE ESH141 Hand and Power Tools (2) ESH707 Accelerator Worker ESH738 GERT (3) ESH196 Hazard Communication ESH376 or 456 Chemical Waste (4) ASDSF6 (5) ESH170 OSHA Lead Standard ESH196 Hazard Communication ESH195 PPE ESH141 Hand and Power Tools (6) ESH195 PPE ESH141 Hand and Power Tools (7) Informal OJT (8) Formal OJT Management Tools: (A) ANL-E ESH Manual SMART (B) APS-SAD APS-CO (C) Waste Handling Procedure Manual Equipment Hazards Engineered Controls Electrical Safety Training References Electrical Safety Procedures Mechanical Safety Training References Mechanical

23

A Multiple View Approach to Support Common Ground in Distributed and Synchronous Geo-Collaboration  

Science Conference Proceedings (OSTI)

In this paper we investigate strategies to support knowledgesharing in distributed, synchronous collaboration. Our goalis to propose, justify, and assess a multiple view approachto support common ground in geo-collaboration within multi-roleteams. We ... Keywords: Multiple views, common ground, distributed and synchronous geo-collaboration

Gregorio Convertino; Craig H. Ganoe; Wendy A. Schafer; Beth Yost; John M. Carroll

2005-07-01T23:59:59.000Z

24

Scaling air quality effects from alternative jet fuel in aircraft and ground support equipment  

E-Print Network (OSTI)

Many of the nation's largest airports, including Los Angeles International Airport, the Hartsfield-Jackson Atlanta International Airport, Chicago O'Hare International Airport and Washington Dulles International Airport are ...

Donohoo, Pearl (Pearl Elizabeth)

2010-01-01T23:59:59.000Z

25

Plant Support Engineering: Nuclear Power Plant Equipment Qualification Reference Manual, Revision 1  

Science Conference Proceedings (OSTI)

This reference manual compiles information on technology, requirements, and experience pertaining to the qualification of safety-related equipment for use in nuclear power plants under normal operating conditions and under adverse environments such as steam line breaks and earthquakes. The manual covers both environmental and seismic qualification of all safety-related electrical and mechanical equipment, but places emphasis on environmental qualification of Class 1E electrical equipment subject to harsh...

2010-09-16T23:59:59.000Z

26

The construction of a collaborative-design platform to support waste electrical and electronic equipment recycling  

Science Conference Proceedings (OSTI)

Recycling of waste electrical and electronic equipment (WEEE) is a very important subject not only from the viewpoint of waste treatment but also from the viewpoint of recovery of valuable materials. In the past, some obstacles make recycling challenging ... Keywords: Collaborative design, Green supply chain management, Life-cycle management, Recycling, Waste electrical and electronic equipment

Tsai Chi Kuo

2010-02-01T23:59:59.000Z

27

Status of Activities to Implement a Sustainable System of MC&A Equipment and Methodological Support at Rosatom Facilities  

SciTech Connect

Under the U.S.-Russian Material Protection, Control and Accounting (MPC&A) Program, the Material Control and Accounting Measurements (MCAM) Project has supported a joint U.S.-Russian effort to coordinate improvements of the Russian MC&A measurement system. These efforts have resulted in the development of a MC&A Equipment and Methodological Support (MEMS) Strategic Plan (SP), developed by the Russian MEM Working Group. The MEMS SP covers implementation of MC&A measurement equipment, as well as the development, attestation and implementation of measurement methodologies and reference materials at the facility and industry levels. This paper provides an overview of the activities conducted under the MEMS SP, as well as a status on current efforts to develop reference materials, implement destructive and nondestructive assay measurement methodologies, and implement sample exchange, scrap and holdup measurement programs across Russian nuclear facilities.

J.D. Sanders

2010-07-01T23:59:59.000Z

28

Experience Based Interview Process for Power Plant Management: With a Pilot Application to Aging of Outage Support Equipment  

Science Conference Proceedings (OSTI)

Plant managers are responsible for ensuring that their facilities meet strategic asset management goals in an increasingly competitive power generation marketplace. This report describes an experience based interview (EBI) method for capturing the knowledge of plant staff to more efficiently identify technical or operational issues and make management decisions that protect assets. Included is a demonstration of the method in a pilot application to aging of support equipment that could impact outages in ...

1999-04-05T23:59:59.000Z

29

Radiation dose assessments to support evaluations of radiological control levels for recycling or reuse of materials and equipment  

Science Conference Proceedings (OSTI)

Pacific Northwest Laboratory is providing Environmental Protection Support and Assistance to the USDOE, Office of Environmental Guidance. Air, Water, and Radiation Division. As part of this effort, PNL is collecting data and conducting technical evaluations to support DOE analyses of the feasibility of developing radiological control levels for recycling or reuse of metals, concrete, or equipment containing residual radioactive contamination from DOE operations. The radiological control levels will be risk-based, as developed through a radiation exposure scenario and pathway analysis. The analysis will include evaluation of relevant radionuclides, potential mechanisms of exposure, and both health and non-health-related impacts. The main objective of this report is to develop a methodology for establishing radiological control levels for recycle or reuse. This report provides the results of the radiation exposure scenario and pathway analyses for 42 key radionuclides generated during DOE operations that may be contained in metals or equipment considered for either recycling or reuse. The scenarios and information developed by the IAEA. Application of Exemption Principles to the Recycle and Reuse of Materials from Nuclear Facilities, are used as the initial basis for this study. The analyses were performed for both selected worker populations at metal smelters and for the public downwind of a smelter facility. Doses to the public downwind were estimated using the US (EPA) CAP88-PC computer code with generic data on atmospheric dispersion and population density. Potential non-health-related effects of residual activity on electronics and on film were also analyzed.

Hill, R.L.; Aaberg, R.L.; Baker, D.A.; Kennedy, W.E. Jr.

1995-07-01T23:59:59.000Z

30

SECOND GENERATION EXPERIMENTAL EQUIPMENT DESIGN TO SUPPORT VOLOXIDATION TESTING AT INL  

SciTech Connect

Voloxidation is a potential head-end process used prior to aqueous or pyrochemical spent-oxide-fuel treatment. The spent oxide fuel is heated to an elevated temperature in oxygen or air to promote separation of the fuel from the cladding as well as volatize the fission products. The Idaho National Laboratory (INL) and the Korea Atomic Energy Research Institute (KAERI) have been collaborating on voloxidation research through a joint International Nuclear Energy Research Initiative (I-NERI). A new furnace and off-gas trapping system (OTS) with enhanced capability was necessary to perform further testing. The design criteria for the OTS were jointly agreed upon by INL and KAERI. First, the equipment must accommodate the use of spent nuclear fuel and be capable of operating in the Hot Fuel Examination Facility (HFEF) at the INL. This primarily means the furnace and OTS must be remotely operational and maintainable. The system requires special filters and distinctive temperature zones so that the fission products can be uniquely captured. The OTS must be sealed to maximize the amount of fission products captured. Finally, to accommodate the largest range of operating conditions, the OTS must be capable of handling high temperatures and various oxidizing environments. The constructed system utilizes a vertical split-tube furnace with four independently controlled zones. One zone is capable of reaching 1200°C to promote the release of volatile fission products. The three additional zones that capture fission products can be controlled to operate between 100-1100°C. A detailed description of the OTS will be presented as well as some initial background information on high temperature seal options.

Dennis L. Wahlquit; Kenneth J. Bateman; Brian R. Westphal

2008-05-01T23:59:59.000Z

31

Key Residential Building Equipment Technologies for Control and Grid Support PART I (Residential)  

Science Conference Proceedings (OSTI)

Electrical energy consumption of the residential sector is a crucial area of research that has in the past primarily focused on increasing the efficiency of household devices such as water heaters, dishwashers, air conditioners, and clothes washer and dryer units. However, the focus of this research is shifting as objectives such as developing the smart grid and ensuring that the power system remains reliable come to the fore, along with the increasing need to reduce energy use and costs. Load research has started to focus on mechanisms to support the power system through demand reduction and/or reliability services. The power system relies on matching generation and load, and day-ahead and real-time energy markets capture most of this need. However, a separate set of grid services exist to address the discrepancies in load and generation arising from contingencies and operational mismatches, and to ensure that the transmission system is available for delivery of power from generation to load. Currently, these grid services are mostly provided by generation resources. The addition of renewable resources with their inherent variability can complicate the issue of power system reliability and lead to the increased need for grid services. Using load as a resource, through demand response programs, can fill the additional need for flexible resources and even reduce costly energy peaks. Loads have been shown to have response that is equal to or better than generation in some cases. Furthermore, price-incentivized demand response programs have been shown to reduce the peak energy requirements, thereby affecting the wholesale market efficiency and overall energy prices. The residential sector is not only the largest consumer of electrical energy in the United States, but also has the highest potential to provide demand reduction and power system support, as technological advancements in load control, sensor technologies, and communication are made. The prevailing loads based on the largest electrical energy consumers in the residential sector are space heating and cooling, washer and dryer, water heating, lighting, computers and electronics, dishwasher and range, and refrigeration. As the largest loads, these loads provide the highest potential for delivering demand response and reliability services. Many residential loads have inherent flexibility that is related to the purpose of the load. Depending on the load type, electric power consumption levels can either be ramped, changed in a step-change fashion, or completely removed. Loads with only on-off capability (such as clothes washers and dryers) provide less flexibility than resources that can be ramped or step-changed. Add-on devices may be able to provide extra demand response capabilities. Still, operating residential loads effectively requires awareness of the delicate balance of occupants health and comfort and electrical energy consumption. This report is Phase I of a series of reports aimed at identifying gaps in automated home energy management systems for incorporation of building appliances, vehicles, and renewable adoption into a smart grid, specifically with the intent of examining demand response and load factor control for power system support. The objective is to capture existing gaps in load control, energy management systems, and sensor technology with consideration of PHEV and renewable technologies to establish areas of research for the Department of Energy. In this report, (1) data is collected and examined from state of the art homes to characterize the primary residential loads as well as PHEVs and photovoltaic for potential adoption into energy management control strategies; and (2) demand response rules and requirements across the various demand response programs are examined for potential participation of residential loads. This report will be followed by a Phase II report aimed at identifying the current state of technology of energy management systems, sensors, and communication technologies for demand response and load factor control applications

Starke, Michael R [ORNL; Onar, Omer C [ORNL; DeVault, Robert C [ORNL

2011-09-01T23:59:59.000Z

32

High Level Waste Remote Handling Equipment in the Melter Cave Support Handling System at the Hanford Waste Treatment Plant  

SciTech Connect

Cold war plutonium production led to extensive amounts of radioactive waste stored in tanks at the Department of Energy's (DOE) Hanford site. Bechtel National, Inc. is building the largest nuclear Waste Treatment Plant in the world located at the Department of Energy's Hanford site to immobilize the millions of gallons of radioactive waste. The site comprises five main facilities; Pretreatment, High Level Waste vitrification, Low Active Waste vitrification, an Analytical Lab and the Balance of Facilities. The pretreatment facilities will separate the high and low level waste. The high level waste will then proceed to the HLW facility for vitrification. Vitrification is a process of utilizing a melter to mix molten glass with radioactive waste to form a stable product for storage. The melter cave is designated as the High Level Waste Melter Cave Support Handling System (HSH). There are several key processes that occur in the HSH cell that are necessary for vitrification and include: feed preparation, mixing, pouring, cooling and all maintenance and repair of the process equipment. Due to the cell's high level radiation, remote handling equipment provided by PaR Systems, Inc. is required to install and remove all equipment in the HSH cell. The remote handling crane is composed of a bridge and trolley. The trolley supports a telescoping tube set that rigidly deploys a TR 4350 manipulator arm with seven degrees of freedom. A rotating, extending, and retracting slewing hoist is mounted to the bottom of the trolley and is centered about the telescoping tube set. Both the manipulator and slewer are unique to this cell. The slewer can reach into corners and the manipulator's cross pivoting wrist provides better operational dexterity and camera viewing angles at the end of the arm. Since the crane functions will be operated remotely, the entire cell and crane have been modeled with 3-D software. Model simulations have been used to confirm operational and maintenance functional and timing studies throughout the design process. Since no humans can go in or out of the cell, there are several recovery options that have been designed into the system including jack-down wheels for the bridge and trolley, recovery drums for the manipulator hoist, and a wire rope cable cutter for the slewer jib hoist. If the entire crane fails in cell, the large diameter cable reel that provides power, signal, and control to the crane can be used to retrieve the crane from the cell into the crane maintenance area. (authors)

Bardal, M.A. [PaR Systems, Inc., Shoreview, MN (United States); Darwen, N.J. [Bechtel National, Inc., Richland, WA (United States)

2008-07-01T23:59:59.000Z

33

The DOE/Gosatomnadzor collaboration, Project 3: Providing equipment and support for Gosatomnadzor inspection activities in Russia  

SciTech Connect

Project 3 consists of two subprojects: Project 3.1 -- providing Materials Control and Accounting (MC and A) equipment to GAN inspectors; and Project 3.2 -- the development of Russian indigenous MC and A equipment capability for GAN. The objective of Project 3.1 is to provide equipment for use by GAN inspectors during independent inspections of facilities that contain direct-use material. To accomplish this, Project 3.1 develops the initial training for GAN instructors on the instruments provided by the US and contracts with Safety Limited, a GAN contractor for developing methodologies and procedures for using the equipment and acceptance checkout and delivery. The equipment deliveries were divided into three phases to fit within the DOE budget and priority constraints. With the equipment delivered to the inspectors, Phase 1 is complete. Phase 2 has been started by purchasing and checking out neutron coincidence counting (NCC) equipment at Los Alamos. The GAN instructors have been trained on NCCs, cherenkov vision devices (CVDs), ultrasonic thickness gages (UTGs), and tamper indicating devices (TIDs) at Los Alamos. Phase 3 has been delayed to fiscal year 1999 (FY99) due to budget constraints. Project 3.2 addresses the important issue of sustainability for safeguards equipment in Russia. GAN`s Project 3.2 will help establish indigenous equipment for Russian safeguards. The initial review of Russian manufacturing capabilities for safeguards equipment has been completed and recommendations have been made. To this end, the authors are encouraging US vendors to collaborate with Russian institutes and have contracted with the All-Russia Research Institute of Automatics (VINIIA) and Aquila Technologies to fabricate a Russian Active-Well Coincidence Counter (AWCC) from US parts.

Hoida, H.W. [Los Alamos National Lab., NM (United States); Lanier, R. [Lawrence Livermore National Lab., CA (United States); Schultz, F. [Oak Ridge National Lab., TN (United States)

1997-12-31T23:59:59.000Z

34

Integrated ground-based and remotely sensed data to support global studies of environmental change  

Science Conference Proceedings (OSTI)

Data centers routinely archive and distribute large databases of high quality and with rigorous documentation but, to meet the needs of global studies effectively and efficiently, data centers must go beyond these traditional roles. Global studies of environmental change require integrated databases of multiple data types that are accurately coordinated in terms of spatial, temporal and thematic properties. Such datasets must be designed and developed jointly by scientific researchers, computer specialists, and policy analysts. The presentation focuses on our approach for organizing data from ground-based research programs so that the data can be linked with remotely sensed data and other map data into integrated databases with spatial, temporal, and thematic characteristics relevant to global studies. The development of an integrated database for Net Primary Productivity is described to illustrate the process.

Olson, R.J.; Turner, R.S.; Garten, C.T.

1994-09-15T23:59:59.000Z

35

The role of the personal computer in the design and development of advanced life-support equipment for tactical aircraft  

Science Conference Proceedings (OSTI)

Pilots of tactical aircraft are exposed to high accelerative forces. Acceleration in the headward direction (+Gz) will decrease blood flow to the head, causing changes in the visual field and/or loss of consciousness. G-protective life-support systems ...

Marty Pecaric

1995-11-01T23:59:59.000Z

36

Support  

NLE Websites -- All DOE Office Websites (Extended Search)

WIPP Support Double Beta Decay Dark Matter Biology Repository Science Renewable Energy Community, State and Congressional Support for WIPP as a host for Underground Experiments...

37

Sales and Use Tax Exemption for Renewable Energy Equipment  

Energy.gov (U.S. Department of Energy (DOE))

In April 2008, the Maryland enacted legislation exempting geothermal and solar energy equipment from the state sales and use tax. Geothermal equipment is defined as "equipment that uses ground loop...

38

Equipment Certification | Open Energy Information  

Open Energy Info (EERE)

Equipment Certification Equipment Certification Jump to: navigation, search Policies requiring renewable energy equipment to meet certain standards serve to protect consumers from buying inferior equipment. These requirements not only benefit consumers; they also protect the renewable energy industry by making it more difficult for substandard systems to reach the market. [1] Equipment Certification Incentives CSV (rows 1 - 19) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Canada Oil and Gas Operations Act (Canada) Environmental Regulations Equipment Certification Fees Generating Facility Rate-Making Generation Disclosure Industry Recruitment/Support Safety and Operational Guidelines Siting and Permitting Canada Commercial Construction Developer

39

Commercial equipment cost database  

SciTech Connect

This report, prepared for DOE, Office of Codes and Standards, as part of the Commercial Equipment Standards Program at Pacific Northwest Laboratory, specifically addresses the equipment cost estimates used to evaluate the economic impacts of revised standards. A database including commercial equipment list prices and estimated contractor costs was developed, and through statistical modeling, estimated contractor costs are related to equipment parameters including performance. These models are then used to evaluate cost estimates developed by the ASHRAE 90.1 Standing Standards Project Committee, which is in the process of developing a revised ASHRAE 90.1 standard. The database will also be used to support further evaluation of the manufacturer and consumer impacts of standards. Cost estimates developed from the database will serve as inputs to economic modeling tools, which will be used to estimate these impacts. Preliminary results suggest that list pricing is a suitable measure from which to estimate contractor costs for commercial equipment. Models developed from these cost estimates accurately predict estimated costs. The models also confirm the expected relationships between equipment characteristics and cost. Cost models were developed for gas-fired and electric water heaters, gas-fired packaged boilers, and warm air furnaces for indoor installation. Because of industry concerns about the use of the data, information was not available for the other categories of EPAct-covered equipment. These concerns must be addressed to extend the analysis to all EPAct equipment categories.

Freeman, S.L.

1995-01-01T23:59:59.000Z

40

Laboratory - Equipment  

Science Conference Proceedings (OSTI)

Available Equipment. A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z. B. Ohaus ... W. Barnstead ...

2013-09-13T23:59:59.000Z

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Equipment Operational Requirements  

SciTech Connect

The Iraq Department of Border Enforcement is rich in personnel, but poor in equipment. An effective border control system must include detection, discrimination, decision, tracking and interdiction, capture, identification, and disposition. An equipment solution that addresses only a part of this will not succeed, likewise equipment by itself is not the answer without considering the personnel and how they would employ the equipment. The solution should take advantage of the existing in-place system and address all of the critical functions. The solutions are envisioned as being implemented in a phased manner, where Solution 1 is followed by Solution 2 and eventually by Solution 3. This allows adequate time for training and gaining operational experience for successively more complex equipment. Detailed descriptions of the components follow the solution descriptions. Solution 1 - This solution is based on changes to CONOPs, and does not have a technology component. It consists of observers at the forts and annexes, forward patrols along the swamp edge, in depth patrols approximately 10 kilometers inland from the swamp, and checkpoints on major roads. Solution 2 - This solution adds a ground sensor array to the Solution 1 system. Solution 3 - This solution is based around installing a radar/video camera system on each fort. It employs the CONOPS from Solution 1, but uses minimal ground sensors deployed only in areas with poor radar/video camera coverage (such as canals and streams shielded by vegetation), or by roads covered by radar but outside the range of the radar associated cameras. This document provides broad operational requirements for major equipment components along with sufficient operational details to allow the technical community to identify potential hardware candidates. Continuing analysis will develop quantities required and more detailed tactics, techniques, and procedures.

Greenwalt, B; Henderer, B; Hibbard, W; Mercer, M

2009-06-11T23:59:59.000Z

42

Collecting Construction Equipment Activity Data from Caltrans Project Records  

E-Print Network (OSTI)

Industrial Law n and Garden Logging Military Tactical Support Misc. Portable Equipment Transport Refrigeration

Kable, Justin M

2008-01-01T23:59:59.000Z

43

Austin-Bergstrom International Airport Electrification: Landside Vehicle and Airside Equipment Operations  

Science Conference Proceedings (OSTI)

Air quality standards nonattainment issues have become an increasingly pressing issue for airports located in metropolitan areas. Research has shown that reduction of ground support equipment (GSE) emissions will be instrumental in meeting emissions standards and facilitating low environmental impact growth. Austin-Bergstrom International Airport (ABIA)located about eight miles southeast of downtown Austin, Texas, and supporting a narrow-body aircraft fleetprovides the perfect test venue for replacing ex...

2011-08-12T23:59:59.000Z

44

Sample-related peripheral equipment at IPNS  

Science Conference Proceedings (OSTI)

This paper describes samples environment equipment provided by IPNS to visiting users and staff scientists. Of the twelve horizontal neutron beam stations, (ten now operational, two under construction) all use one or more form of such support equipment. An in-house support group devotes a significant fraction of its time to development, calibration, and maintenance of this equipment.

Bohringer, D.E.; Crawford, R.K.

1985-01-01T23:59:59.000Z

45

Categorical Exclusion 4565, Waste Management Construction Support  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

FornI FornI Project Title: Waste Management Construction Support (4565) Program or Program Office: Y -12 Site Office Location: Oak Ridge Tennessee Project Description: This work scope is an attempt to cover the general activities that construction would perform in support of Waste Management activities. Work includes construction work performed in support of Waste Management Sustainability and Stewardship projects and programs to include: load waste into containers; open, manipulate containers; empty containers; decommission out-of-service equipment (includes removal of liquids, hazardous, and universal wastes); apply fabric and gravel to ground; transport equipment; transport materials; transport waste; remove vegetation; place barriers; place erosion controls; operate wheeled and tracked equipment; general carpentry. Work will be performed on dirt, vegetated, graveled, or paved surfaces in

46

Equipment Certification Requirements | Open Energy Information  

Open Energy Info (EERE)

Equipment Certification Requirements Equipment Certification Requirements Jump to: navigation, search Policies requiring renewable energy equipment to meet certain standards serve to protect consumers from buying inferior equipment. These requirements not only benefit consumers; they also protect the renewable energy industry by making it more difficult for substandard systems to reach the market. [1] Contents 1 Equipment Certification Incentives 2 References Equipment Certification Incentives CSV (rows 1 - 19) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Canada Oil and Gas Operations Act (Canada) Environmental Regulations Equipment Certification Fees Generating Facility Rate-Making Generation Disclosure Industry Recruitment/Support Safety and Operational Guidelines

47

Laboratory Equipment Donation Program - Equipment Applications  

Office of Scientific and Technical Information (OSTI)

Specific questions concerning equipment should be directed to the point of Specific questions concerning equipment should be directed to the point of contact responsible for the item(s) under consideration. This information is listed on the "Equipment Information" page, as well as on the grant award e-mail sent to the applicant. Step 1: Search and Apply for Equipment Note: If you know the Item Control Number of the equipment you need, you may go directly to the on-line application. Please follow these procedures to "Search Equipment" and apply for equipment using the LEDP Online Application: Select the "Search Equipment" menu link. Enter the type of equipment desired into the search box or choose the "Equipment List" link, which will allow you see a complete list of available equipment. Select the "Item Control Number" for the desired equipment. This

48

GPHS-RTGs in support of the Cassini mission. Semi-annual technical report, 29 March 1993--26 September 1993  

DOE Green Energy (OSTI)

The following tasks were reported on: Spacecraft integration and liaison, engineering support, safety, qualified unicouple fabrication, ETG fabrication/assembly/test, ground support equipment, RTG shipping and launch support, designs/reviews/mission applications, project management/quality assurance/contract changes.

Not Available

1993-10-24T23:59:59.000Z

49

Equipment Maintenance Optimization Manual Applications  

Science Conference Proceedings (OSTI)

This report is a compilation of Equipment Maintenance Optimization Manuals (EMOMs) that include procedures and troubleshooting supported by broad-based utility experience. EMOMs for critical generating station equipment allows power generating plants to replace existing maintenance practices with the latest industry best practices. Using this information as a benchmark, current practices can be validated or adjusted for more optimum performance of the overall maintenance process. In addition, the EMOMs c...

2001-12-21T23:59:59.000Z

50

Equipment Maintenance Optimization Manual Prototypes  

Science Conference Proceedings (OSTI)

This report provides detailed information to assist plant staff in performing recommended equipment maintenance tasks. It is a compilation of equipment maintenance optimization manual (EMOM) prototypes that include procedures and trouble shooting supported by broad-based utility experience. The EMOMs enable utility generation stations to: minimize operation and maintenance costs, including parts and labor; assist in maintenance planning, scheduling, and parts strategy; develop comprehensive maintenance m...

1999-11-24T23:59:59.000Z

51

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology  

SciTech Connect

The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

Not Available

1993-11-01T23:59:59.000Z

52

Characterization equipment essential drawing plan  

SciTech Connect

The purpose of this document is to list the Characterization equipment drawings that are classified as Essential Drawings and Support Drawings. Essential Drawings: Are those drawings identified by the facility staff as necessary to directly support the safe operation of the facility or equipment (HNF 1997a). Support Drawings: Are those drawings identified by facility staff that further describe the design details of structures, systems, or components shown on essential drawings. (HNF 1997a) The Characterization equipment drawings identified in this report are deemed essential drawings as defined in HNF-PRO-242, Engineering Drawing Requirements (HNF 1997a). These drawings will be prepared, revised, and maintained per HNF-PRO-440, Engineering Document Change Control (HNF 1997b). All other Characterization equipment drawings not identified in this document will be considered General drawings until the Characterization Equipment Drawing Evaluation Report (Wilson 1998) is updated during fiscal year 1999. Trucks 1 and 2 drawings are not included in this revision of the essential drawing list due to uncertainty about future use.

WILSON, G.W.

1999-05-14T23:59:59.000Z

53

Supporting Equipment for Heating and Cooling Systems  

Energy.gov (U.S. Department of Energy (DOE))

Thermostats and ducts provide opportunities for saving energy. Dehumidifying heat pipes provide a way to help central air conditioners and heat pumps dehumidify air. Electric and gas meters allow users to track energy use.

54

Laboratory Equipment Donation Program - Equipment Information  

Office of Scientific and Technical Information (OSTI)

Description: Location of Equipment: Address Line 2: Address Line 3: City: State: Zip: Contact: Phone: Fax: Email address: Quantity: Original Acquisition Cost: 0.00 U.S....

55

Grounding intentionality  

E-Print Network (OSTI)

In this thesis, I argue that current attempts to ground intentionality face one of two challenges. Either the grounding feature of intentionality will be itself intentional or the grounding feature is disparate in nature from the representational capacity of an intentional mental state and therefore no connection between the two can be taken to exist. I examine two current accounts of intentionality and the features they utilize to ground it. I maintain that both views fall prey to one or both of the objections I raise. I conclude that any account of intentionality will need to meet both of these challenges in order to be counted successful.

Huizenga Steven R

2004-01-01T23:59:59.000Z

56

PNNL: EDO - Facilities & Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

Facilities & Equipment Facilities & Equipment Facilities Equipment Decades of government investment on and around the Pacific Northwest National Laboratory campus has made PNNL a business-friendly resource for conducting a wide range of research. As a mission-focused organization, we are dedicated to teaming with government agencies, industry and academia to address what we believe are among the nation's most pressing needs in the areas of energy, environment, national security, and fundamental science. But behind these important missions is a wealth of supporting capabilities including incubator space, research laboratories, and user facilities that may be just what your business needs. We invite you to learn more about how we can work with businesses as well as what research laboratories and user facilities are available.

57

GPHS-RTGs in support of the Cassini Mission. Semiannual technical progress report, 27 September 1993--27 March 1994  

DOE Green Energy (OSTI)

This report is organized by the program task structure as follows: (1) spacecraft integration and liaison; (2) engineering support; (3) safety; (4) qualified unicouple fabrication; (5) ETG fabrication, assembly, and test; (6) ground support equipment (GSE); (7) RTG shipping and launch support; (8) designs, reviews, and mission applications; (9) project management, quality assurance and reliability, contract changes, non-capital CAGO acquisition, and CAGO maintenance; and (H) contractor acquired government owned property (CAGO) acquisition.

Not Available

1994-04-24T23:59:59.000Z

58

Ground Water  

NLE Websites -- All DOE Office Websites (Extended Search)

Water Nature Bulletin No. 408-A February 27, 1971 Forest Preserve District of Cook County George W. Dunne, President Roland F. Eisenbeis, Supt. of Conservation GROUND WATER We take...

59

System for detecting and limiting electrical ground faults within electrical devices  

DOE Patents (OSTI)

An electrical ground fault detection and limitation system for employment with a nuclear reactor utilizing a liquid metal coolant. Elongate electromagnetic pumps submerged within the liquid metal coolant and electrical support equipment experiencing an insulation breakdown occasion the development of electrical ground fault current. Without some form of detection and control, these currents may build to damaging power levels to expose the pump drive components to liquid metal coolant such as sodium with resultant undesirable secondary effects. Such electrical ground fault currents are detected and controlled through the employment of an isolated power input to the pumps and with the use of a ground fault control conductor providing a direct return path from the affected components to the power source. By incorporating a resistance arrangement with the ground fault control conductor, the amount of fault current permitted to flow may be regulated to the extent that the reactor may remain in operation until maintenance may be performed, notwithstanding the existence of the fault. Monitors such as synchronous demodulators may be employed to identify and evaluate fault currents for each phase of a polyphase power, and control input to the submerged pump and associated support equipment.

Gaubatz, Donald C. (Cupertino, CA)

1990-01-01T23:59:59.000Z

60

Background chemistry for chemical warfare agents and decontamination processes in support of delisting waste streams at the U.S. Army Dugway Proving Ground, Utah  

SciTech Connect

The State of Utah, Department of Environmental Quality (DEQ), Division of Solid and Hazardous Waste (DSHW), has declared residues resulting from the demilitarization, treatment, cleanup, and testing of military chemical agents to be hazardous wastes. These residues have been designated as corrosive, reactive, toxic, and acute hazardous (Hazardous Waste No. F999). The RCRA regulations (40 Code of Federal Regulations [CFR] 260-280), the Utah Administrative Code (R-315), and other state hazardous waste programs list specific wastes as hazardous but allow generators to petition the regulator to {open_quotes}delist,{close_quotes} if it can be demonstrated that such wastes are not hazardous. The U.S. Army Test and Evaluation Command (TECOM) believes that certain categories of F999 residues are not hazardous and has obtained assistance from Argonne National Laboratory (Argonne) to make the delisting demonstration. The objective of this project is to delist chemical agent decontaminated residues resulting from materials testing activities and to delist a remediation residue (e.g., contaminated soil). To delist these residues, it must be demonstrated that the residues (1) do not contain hazardous quantities of the listed agents; (2) do not contain hazardous quantities of constituents listed in 40 CFR Part 261, Appendix VIII; (3) do not exhibit other characteristics that could define the residues as hazardous; and (4) do not fail a series of acute toxicity tests. The first phase will focus on a subset of the F999 wastes generated at the U.S. Army Dugway Proving Ground (DPG), where the Army tests the effects of military chemical agents and agent-decontamination procedures on numerous military items. This effort is identified as Phase I of the Delisting Program. Subsequent phases will address other DPG chemical agent decontaminated residues and remediation wastes and similar residues at other installations.

Rosenblatt, D.H.; Small, M.J.; Kimmell, T.A.; Anderson, A.W.

1996-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

List of Data Center Equipment Incentives | Open Energy Information  

Open Energy Info (EERE)

Equipment Incentives Equipment Incentives Jump to: navigation, search The following contains the list of 17 Data Center Equipment Incentives. CSV (rows 1 - 17) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Alliant Energy Interstate Power and Light (Electric) - Business Energy Efficiency Rebate Programs (Minnesota) Utility Rebate Program Minnesota Commercial Fed. Government Local Government Nonprofit Retail Supplier State Government Central Air conditioners Heat pumps Lighting Lighting Controls/Sensors Programmable Thermostats Refrigerators Windows Room Air Conditioners Ground Source Heat Pumps Building Insulation Clothes Washers Comprehensive Measures/Whole Building Dishwasher Water Heaters LED Exit Signs Commercial Refrigeration Equipment Data Center Equipment

62

List of Personal Computing Equipment Incentives | Open Energy Information  

Open Energy Info (EERE)

Personal Computing Equipment Incentives Personal Computing Equipment Incentives Jump to: navigation, search The following contains the list of 21 Personal Computing Equipment Incentives. CSV (rows 1 - 21) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Alexandria Light and Power - Commercial Energy Efficiency Rebate Program (Minnesota) Utility Rebate Program Minnesota Commercial Industrial Central Air conditioners Chillers Compressed air Custom/Others pending approval Heat pumps Lighting Motor VFDs Motors Programmable Thermostats Water Heaters Windows Commercial Refrigeration Equipment Personal Computing Equipment Ground Source Heat Pumps Yes Avista Utilities (Electric) - Commercial Energy Efficiency Incentives Program (Idaho) Utility Rebate Program Idaho Commercial

63

Condition Assessment of Substation Ground Grids  

Science Conference Proceedings (OSTI)

This report describes the first stage of research to develop a simple and inexpensive method and device to assess the integrity of substation grounding grids. The problem has been studied before but there is not, to our knowledge, a reliable and inexpensive method or device to make a reliable diagnosis. While the EPRI-developed Ground Grid Evaluator (commercially knows as the Smart Ground Multimeter or SGM) can be used to provide valuable information, the equipment is considered to be expensive and requi...

2008-03-26T23:59:59.000Z

64

Condition Assessment of Substation Ground Grids  

Science Conference Proceedings (OSTI)

This report describes the second stage of a research project to develop a simple and inexpensive method and device to assess the integrity of substation grounding grids. The problem has been studied before but a reliable and inexpensive method or device to make a reliable diagnosis of grid condition is still lacking. While the EPRI-developed Ground Grid Evaluator (commercially known as the Smart Ground Multimeter) can be used to provide valuable information, the equipment is expensive and requires extens...

2008-12-17T23:59:59.000Z

65

Laboratory Equipment Donation Program - Equipment List  

Office of Scientific and Technical Information (OSTI)

Equipment List Equipment List Already know the item control number? Submit Reset Item Control Number Equipment Name Date Entered Condition Picture 89022833290004 1300594 TLD DETECTOR 12/16/2013 Repairable N/A 89022833290005 1300595 PICOMETER 12/16/2013 Repairable N/A 89022833290008 1300598 READER 12/16/2013 Repairable N/A 89022833290010 1300600 DETECTOR VACUUM PUMP 12/16/2013 Repairable N/A 89022833290016 1300606 TLD READER 12/16/2013 Repairable N/A 89022833290018 1300608 READER 12/16/2013 Repairable N/A 89022833290019 1300609 ANALYZER WITH DETECTOR 12/16/2013 Repairable N/A 89022833180013 1300993 PRESSURE REGULATOR 12/04/2013 Repairable N/A 89022833180022 1301098 VACUUM GAUGE 12/04/2013 Repairable N/A 89022833180023 1301099 OSCILLOSCOPE 12/04/2013 Repairable N/A

66

GPHS-RTGs in support of the Cassini Mission. Semi annual technical progress report, 28 March 1994--25 September 1994  

DOE Green Energy (OSTI)

The progress on the radioisotope generators and ancillary activities is described. This report is organized by program task as follows: spacecraft integration and liaison; engineering support; safety; qualified unicouple fabrication; ETG fabrication, assembly, and test; ground support equipment; RTG shipping and launch support; design, reviews, and mission applications; project management, quality assurance and reliability, contract changes, non-capital CAGO acquisition, and CAGO maintenance; contractor acquired government owned property (CAGO) acquisition.

Not Available

1994-10-20T23:59:59.000Z

67

Experimental Equipment | Stanford Synchrotron Radiation Lightsource  

NLE Websites -- All DOE Office Websites (Extended Search)

Equipment Equipment SSRL plans the distribution of its limited equipment on the basis of the information supplied on the Beam Time Request Form and the User Support Requirements Form. Please make sure to state all of your needs. Standard X-Ray Station Equipment Standard equipment to be found on an x-ray station includes: (1 ea.) Small and large ionization chambers (1) Exit slits (1) X-Y sample positioner (3) Keithly 427 current-to-voltage amplifier TEK 2215 60 MHZ 2 channel scope Voltage-to-frequency converter (3 channels) (1) Fluke high voltage power supply (1) Kinetic Systems hex scaler (1) Kinetic Systems up-down presettable counter (1) Ortec real-time clock (2) Joerger stepping motor controller DSP Micro VAX or Kinetic Systems G.I./CAMAC crate controller (1) Standard Engineering Corporation CAMAC power supply

68

RMOTC - Field Information - Equipment and Facilities  

NLE Websites -- All DOE Office Websites (Extended Search)

Equipment & Facilities Equipment & Facilities Motor Grader at RMOTC Notice: As of July 15th 2013, the Department of Energy announced the intent to sell Naval Petroleum Reserve Number 3 (NPR3). The sale of NPR-3 will also include the sale of all equipment and materials onsite. A decision has been made by the Department of Energy to complete testing at RMOTC by July 1st, 2014. RMOTC will complete testing in the coming year with the currently scheduled testing partners. For more information on the sale of NPR-3 and sale of RMOTC equipment and materials please join our mailing list here. RMOTC's test facility has its own line of workover, support, and heavy equipment available for partner use on site. RMOTC can also offer its partners workspace on site in its Customer Operations Center which has

69

Superconducting Power Equipment  

Science Conference Proceedings (OSTI)

The 2010 Electric Power Research Institute (EPRI) Technology Watch (Techwatch) report on superconducting power applications (EPRI report 1019995, Superconducting Power Equipment: Technology Watch 2010) introduced coverage about superconducting magnetic energy storage systems and superconducting transformers. The 2011 report contains additional information about superconducting power equipment, including progress to demonstrations in some projects. The 2011 report also includes a section on superconductin...

2011-12-22T23:59:59.000Z

70

Gas insulated substation equipment for industrial applications  

SciTech Connect

Until recently the only available method for construction of high voltage systems was to use exposed air insulated equipment supported on porcelain columns. The past decade has witnessed the introduction and wide acceptance of compressed gas insulated equipment as a viable alternative to the conventional substation system. The characteristics of gas insulated substations (GIS) and their application for industrial use at service voltages at 69 kV and above are discussed.

Kenedy, J.J.

1984-11-01T23:59:59.000Z

71

PNNL: EDO - Entrepreneur Support Catalog  

NLE Websites -- All DOE Office Websites (Extended Search)

Protg Program Research District Entrepreneur Support Catalog Facilities & Equipment PNNL Available Technologies Collaborative Research at PNNL Useful Publications TechBiz...

72

Pollution Control Equipment Tax Deduction (Alabama) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pollution Control Equipment Tax Deduction (Alabama) Pollution Control Equipment Tax Deduction (Alabama) Pollution Control Equipment Tax Deduction (Alabama) < Back Eligibility Commercial Construction Developer Industrial Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State Alabama Program Type Corporate Tax Incentive The Pollution Control Equipment Tax Deduction allows businesses to deduct from their Alabama net worth the net amount invested in all devices, facilities, or structures, and all identifiable components or materials for use therein, that are located in Alabama and are acquired or constructed primarily for the control, reduction, or elimination of air, ground, or water pollution or radiological hazards where such pollution or

73

List of Commercial Refrigeration Equipment Incentives | Open Energy  

Open Energy Info (EERE)

Refrigeration Equipment Incentives Refrigeration Equipment Incentives Jump to: navigation, search The following contains the list of 103 Commercial Refrigeration Equipment Incentives. CSV (rows 1 - 103) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Appalachian Power - Commercial and Industrial Rebate Programs (West Virginia) Utility Rebate Program West Virginia Commercial Industrial Central Air conditioners Chillers Custom/Others pending approval Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Programmable Thermostats Commercial Refrigeration Equipment Ground Source Heat Pumps Yes AEP Ohio - Commercial New Construction Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Industrial Local Government Municipal Utility

74

Energy Audit Equipment  

E-Print Network (OSTI)

The tools (equipment) needed to perform an energy audit include those items which assist the auditor in measuring the energy used by equipment or lost in inefficiency. Each tool is designed for a specific measurement. They can be inexpensive simple tools or expensive technically complex or multifunctional tools. In general, tools are needed which measure light, temperature and humidity, electricity, air flow, heat loss, and general energy information.

Phillips, J.

2012-01-01T23:59:59.000Z

75

Grid Equipment Reliability Study  

Science Conference Proceedings (OSTI)

Throughout the world, utilities have witnessed changes to electrical power markets. These changes have presented new and continuous challenges to maintaining the transmission system's integrity. In the past, emphasis at the transmission level has been on the system as a whole and not at the equipment level. This report summarizes the finding of a study that investigated the need to develop a new set of metrics and benchmarks to measure and compare grid equipment performance.

2001-12-10T23:59:59.000Z

76

Alternative Materials for Ground Electrodes  

Science Conference Proceedings (OSTI)

Power utility companies struggle with issues resulting from copper theftespecially on transmission line support structures accessible to the public and fitted with copper grounding conductors. It is increasingly important to identify alternative materials that can be used to provide a durable grounding system yet not be targeted for theft. In response, EPRI is investigating the use of alternative materials for electrode designsexamining life expectancy, corrosion, material compatibility and current handl...

2010-12-23T23:59:59.000Z

77

Electricity Used by Office Equipment and Network Equipment in...  

NLE Websites -- All DOE Office Websites (Extended Search)

: Detailed Report and Appendices Title Electricity Used by Office Equipment and Network Equipment in the U.S.: Detailed Report and Appendices Publication Type Report LBNL Report...

78

Equipment Inventory | Sample Preparation Laboratories  

NLE Websites -- All DOE Office Websites (Extended Search)

Equipment Inventory Equipment Resources Title Equipment Type Facility Laboratory Building Room Accumet Basic AB15 pH meter pH Meter SSRL BioChemMat Prep Lab 2 131 209 Agate...

79

International Cooperation on Advancing Equipment and Appliance Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Equipment and Equipment and Appliance Efficiency The Superefficient Equipment and Appliance Deployment (SEAD) Initiative 1 What is SEAD? * SEAD is a global market transformation initiative for deploying super-efficient equipment and appliances. * SEAD has three goals: - To raise the efficiency ceiling * Pull super-efficient appliances and equipment into the market through cooperation on measures like incentives, procurement, awards, and R&D investments - To raise the efficiency floor * Work together to bolster national or regional policies like minimum efficiency standards - To strengthen the foundations of efficiency programs * Coordinate technical work to support these activities 2 SEAD Partners Australia European Commission Canada France Germany India Japan Korea Mexico

80

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

subpart W. Statutory Authority The current energy conservation standards for commercial refrigeration equipment are mandated by Part A-1, the "Certain Industrial Equipment" of...

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Laboratory Equipment | ORNL Neutron Sciences  

NLE Websites -- All DOE Office Websites (Extended Search)

Home Facilities Scientific Labs Equipment Query Equipment Lab: HFIR - Biology Lab HFIR - Post Beam Sample Handling Lab HFIR - User Chemistry Lab High Pressure Lab SNS -...

82

Equipment Insulation | Open Energy Information  

Open Energy Info (EERE)

Login | Sign Up Search Page Edit History Facebook icon Twitter icon Equipment Insulation Jump to: navigation, search TODO: Add description List of Equipment Insulation...

83

NSLS Electrical Equipment Inspection  

NLE Websites -- All DOE Office Websites (Extended Search)

Electrical Equipment Inspection Information Electrical Equipment Inspection Information A note to vendors visiting NSLS A note to users visiting NSLS Proteus Electrical Conformity Remediation Currently Certified Electrical Equipment Inspectors: First Line Contacts Email Extension Poshka, Dennis poshka@bnl.gov 2825 Alternate Contacts Boerner Jr, Albert aboerner@bnl.gov 5990 Buda, Scott buda@bnl.gov 3914 Caruso, Michael caruso@bnl.gov 4100 Chmiel, Robert chmiel@bnl.gov 8141 Church, Randolph church@bnl.gov 2736 Clay, Barret clay@bnl.gov 7284 D'Alsace, Roy dalsace@bnl.gov 3973 Danneil, Christopher cdanneil@bnl.gov 8609 Davila, Peter davila@bnl.gov 7625 De Toll, Peter detoll@bnl.gov 4100 Durfee, Douglas ddurfee@bnl.gov 7625 Fulkerson, Michael fulkerso@bnl.gov 5194 Gallagher, John jgallagher@bnl.gov 5770 Harder, David dharder@bnl.gov 4978

84

Scientist Equipment and Outline  

NLE Websites -- All DOE Office Websites (Extended Search)

Outline and Equipment Outline and Equipment LIGHT AND COLOR Grade levels: can be adapted for grades 2-8. Length of time: 30-45 minues. Room preference: Double classroom or all-purpose room. Equipment is located in the Lederman Science Center. Talk to Susan Dahl to borrow this set. Spectrum tube power supply, gas tubes and diffraction grating glasses Light box with red, green, and blue translucent film Power chord, extension chord Large set of lenses Small concave and convex lenses Magnetic optics kit, includes a small laser Slinky Flashlight Clear plastic tub, powdered milk Water Radiometer Electromagnetic energy spectrum poster Set of red, green and blue flood lights Where does light come from? Use a boy and a girl to make a human demonstration of molecules and atoms. Have students rub their hands together and notice friction equals heat.

85

GPHS-RTGs in support of the CRAF/Cassini missions  

DOE Green Energy (OSTI)

The technical progress achieved during the period 30 September 1911 through 29 March 1992 on Contract DE-AC03-91SF18852.000 Radioisotope Thermoelectric Generators and Ancillary Activities is described in this document. This report is organized by the program task structure as follows: spacecraft integration and liaison, engineering support, safety, qualified unicouple production, ETG fabrication, assembly and test, ground support equipment (GSE), RTG shipping and launch support, designs, reviews, and mission applications, project management, quality assurance, reliability, contract changes, and non-capital CAGO, and CAGO acquisition (Capital Funds).

Not Available

1992-04-20T23:59:59.000Z

86

Office Equipment Energy Use  

Science Conference Proceedings (OSTI)

Miscellaneous electric loads in office buildings consume nearly 58 billion kilowatt hours per year, which translates to $6.1 billion in electricity costs to businesses. Most office space is not sub metered, thus making it difficult for tenants to know how much electricity they use. Consequently, they are unable to see how the amount they pay for their space is affected by the efficiency of equipment they choose and how they operate it. By using recommended power-saving equipment and best practices outlin...

2010-12-16T23:59:59.000Z

87

Ground Loops for Heat Pumps and Refrigeration  

E-Print Network (OSTI)

Ground loops are used for water source heat pumps. Refrigeration can be put on a ground loop. Water-cooled condensing units are more efficient than air-cooled, and they can be put indoors. Indoor location makes piping for desuperheater hot water easy. Since refrigeration equipment runs more than heat pumps, energy savings can be large for ground-coupled refrigeration. The paper presents a design procedure for ground loops for heat pumps, hot water, ice machines, and water-cooled refrigeration. It gives an overview of the commercial ground-coupled systems in Louisiana that have both refrigeration and heat pumps. Systems vary from small offices to a three-story office building with 187 tons. A chain of hamburger outlets uses total ground-coupling in all of its stores. A grocery store has ground-coupling for heat pumps and refrigeration. Desuperheaters provide 80 percent of the hot water for a coin laundry in the same building. A comparison of energy costs in a bank with a ground-coupled heat pump system to a similar bank with air-conditioning and gas for heat revealed a 31 percent reduction in utility costs for the ground-coupled building. Two buildings of the Mississippi Power and Light Co. have ground-coupled heat pumps in one, and high efficiency air source heat pumps in the other. Energy savings in nine months was 60,000 kWh (25 percent), and electric peak demand was reduced 42 kW (35 percent).

Braud, H. J.

1986-01-01T23:59:59.000Z

88

Appendix G Supporting Documentation  

Office of Legacy Management (LM)

Supporting Documentation Supporting Documentation for Focused Feasibility Study This page intentionally left blank Contents Section Ground Water Models for Alternatives 3 and 4 ........................................................................ G .O Human Health Risk Assessment Calculations ........................................................................... G2.0 Cost Analysis ........................................................................................................................... G3.0 This page intentionally left blank Section G1.0 Ground Water Models for Alternatives 3 and 4 This page intentionally left blank D o c o l ~ ~ e n t Nurt~her Q0029500 Appendix G MMTS OU 111 Feasibility Study Ground Water Modeling for Alternative 3: PRB Treatment Objective

89

field_equipment.indd  

NLE Websites -- All DOE Office Websites (Extended Search)

EQUIPMENT INVENTORY EQUIPMENT INVENTORY Trucks * Five vac/pressure trucks, 60-90 bbl, up to 5 bpm at 5,000 lb. * Water/fi re truck, 110 bbl * Two dump trucks: 5-yard and 12-yard * Belly dump trailer * Chemical injection truck, 20 bbl capacity * Three crane trucks: 6,000 lb., 8,000 lb., and 30 ton * Klaeger swab truck * Rig-up truck with 21-foot poles, 30,000-lb. capacity * Winch truck, 40,000-lb. capacity * Two bucket trucks: 25-foot and 28-foot reach * Two welding trucks with Miller Trailblazer welder * Two Ditch Witches: 8" x 7' and 6" x 3" * International PayStar 5000 transport truck * Western Star transport truck Backhoes & Loaders * John Deere 410G backhoe * Cat 420 backhoe * Case 20W loader with 2-yard bucket * Bobcat skid loader with bucket, forks, post hole digger, and trencher attachments

90

Foodservice Equipment Applications Handbook  

Science Conference Proceedings (OSTI)

A typical foodservice operation may spend 75 percent or more of its energy dollar to provide lighting, refrigeration, ventilation, and miscellaneous end uses. Performance characteristics and operational advantages make electricity an excellent option for powering major cooking equipment. This handbook describes the six most common types of major cooking appliances--griddles, fryers, broilers, ovens, ranges, and kettles--including typical applications and industry purchasing trends. Such information will ...

1996-03-26T23:59:59.000Z

91

Potline Operation II: Equipment  

Science Conference Proceedings (OSTI)

Mar 6, 2013 ... With amperage creep, the cross-over busbars electrical insulation of this ... the hot conductors-to-cold supports differential thermal expansion.

92

Design Ground Snow Loads for Ohio  

Science Conference Proceedings (OSTI)

The weight of snow with a mean recurrence interval of 50 years, called the design ground snow load, is used by engineers and planners to estimate the weight of snow that roofs must be designed to support National maps of ground snow load have ...

Thomas W. Schmidlin; Dennis J. Edgell; Molly A. Delaney

1992-06-01T23:59:59.000Z

93

Resistance to ground of combined grid-multiple rods electrodes  

SciTech Connect

The resistance to ground of substations ground electrodes is one of the most important parameters determining the potential rise of the grounded equipment and other metal work within substation with respect to the remote earth as well as the potentials which might be transferred outside the substation. The resistance to ground of a wide set of square and rectangular grid electrodes combined with multiple rods, buried in uniform and two-layer soils, has been analyzed using available exact computer software. Based upon the results of this analysis, analytical expressions and graphs for electrodes resistance to ground are provided, appropriate for practical application.

Nahman, J.M. [Faculty of Electrical Engineering, Belgrade (Yugoslavia)] [Faculty of Electrical Engineering, Belgrade (Yugoslavia); Djordjevic, V.B. [Energoprojekt-Hidroinzenjering, Belgrade (Yugoslavia)] [Energoprojekt-Hidroinzenjering, Belgrade (Yugoslavia)

1996-07-01T23:59:59.000Z

94

Validation of International Atomic Energy Agency Equipment Performance Requirements  

Science Conference Proceedings (OSTI)

Performance requirements and testing protocols are needed to ensure that equipment used by the International Atomic Energy Agency (IAEA) is reliable. Oak Ridge National Laboratory (ORNL), through the US Support Program, tested equipment to validate performance requirements protocols used by the IAEA for the subject equipment categories. Performance protocol validation tests were performed in the Environmental Effects Laboratory in the categories for battery, DC power supply, and uninterruptible power supply (UPS). Specific test results for each piece of equipment used in the validation process are included in this report.

Chiaro, PJ

2004-02-17T23:59:59.000Z

95

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Part A-1 of Title III (42 U.S.C. 6311-6317) establishes a similar program for ''Certain Industrial Equipment,'' which includes commercial refrigeration equipment. Amendments to...

96

China production equipment sourcing strategy  

E-Print Network (OSTI)

This thesis recommends a China business and equipment strategy for the Controls Conveyor Robotics Welding (CCRW) group at General Motors. The current strategy is to use globally common equipment through predetermined global ...

Chouinard, Natalie, 1979-

2009-01-01T23:59:59.000Z

97

GPHS-RTGs in support of the Cassini Mission. Semi annual technical report, 30 September 1996--30 March 1997  

DOE Green Energy (OSTI)

The technical progress achieved during the period 27 January through 30 September 1996 through 30 March 1997 on Contract DE-AC03-91SF18852 Radioisotope Thermoelectric Generators and Ancillary Activities is described. This report is organized by program task structure: spacecraft integration and liaison; engineering support; safety; qualified unicouple production; ETG fabrication, assembly, and test; ground support equipment (GSE); RTG shipping and launch support; designs, reviews, and mission applications; project management, quality assurance, reliability, contract changes, CAGO acquisition (operating funds), and CAGO maintenance and repair; and CAGO acquisition (capital funds).

NONE

1997-04-20T23:59:59.000Z

98

Substation Equipment Life Extension Guidelines  

Science Conference Proceedings (OSTI)

Utilities are under increasing pressure to maintain service reliability while operating aging transmission substations with leaner maintenance budgets and fewer experienced personnel. A structured life extension program can help utilities make equipment maintenance, replacement, and refurbishment decisions that ensure safe, reliable, cost-effective operation of transmission substation equipment. The Electric Power Research Institute (EPRI) report Life Extension Guidelines for Substation Equipment-Fi...

2011-12-21T23:59:59.000Z

99

Tools and Equipment Modeling for Automobile Interactive Assembling Operating Simulation  

SciTech Connect

Tools and equipment play an important role in the simulation of virtual assembly, especially in the assembly process simulation and plan. Because of variety in function and complexity in structure and manipulation, the simulation of tools and equipments remains to be a challenge for interactive assembly operation. Based on analysis of details and characteristics of interactive operations for automobile assembly, the functional requirement for tools and equipments of automobile assembly is given. Then, a unified modeling method for information expression and function realization of general tools and equipments is represented, and the handling methods of manual, semi-automatic, automatic tools and equipments are discussed. Finally, the application in assembly simulation of rear suspension and front suspension of Roewe 750 automobile is given. The result shows that the modeling and handling methods are applicable in the interactive simulation of various tools and equipments, and can also be used for supporting assembly process planning in virtual environment.

Wu Dianliang; Zhu Hongmin [Shanghai Jiao Tong University (China); Shanghai Key Laboratory of Advance Manufacturing Environment (China)

2010-05-21T23:59:59.000Z

100

Transmission Line Grounding  

Science Conference Proceedings (OSTI)

In 2008, the Electric Power Research Institute (EPRI) published a comprehensive grounding report. Published in two parts, the report covered the theoretical and practical aspects of transmission line grounding practices. To further improve the tools available for grounding analysis, an investigation into practical ways to calculate the fault current distribution and ground potential rise of the transmission line grounding system was conducted. Furthermore, a survey of utilities has documented industry pr...

2011-12-23T23:59:59.000Z

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

TANKS 18 AND 19-F EQUIPMENT GROUT FILL MATERIAL EVALUATION AND RECOMMENDATIONS  

SciTech Connect

The United States Department of Energy (US DOE) intends to remove Tanks 18-F and 19-F at the Savannah River Site (SRS) from service. The high-level waste (HLW) tanks have been isolated from the F-area Tank Farm (FTF) facilities and will be filled with cementitious grout for the purpose of: (1) physically stabilizing the empty volumes in the tanks, (2) limiting/eliminating vertical pathways from the surface to residual waste on the bottom of the tanks, (3) providing an intruder barrier, and (4) providing an alkaline, chemical reducing environment within the closure boundary to limit solubility of residual radionuclides. Bulk waste and heel waste removal equipment will remain in Tanks 18-F and 19-F when the tanks are closed. This equipment includes: mixer pumps, transfer pumps, transfer jets, equipment support masts, sampling masts and dip tube assemblies. The current Tank 18-F and 19-F closure strategy is to grout the internal void spaces in this equipment to eliminate fast vertical pathways and slow water infiltration to the residual material on the tank floor. This report documents the results of laboratory testing performed to identify a grout formulation for filling the abandoned equipment in Tanks 18-F and 19-F. The objective of this work was to formulate a flowable grout for filling internal voids of equipment that will remain in Tanks 18-F and 19-F during the final closures. This work was requested by V. A. Chander, Tank Farm Closure Engineering, in HLW-TTR-2011-008. The scope for this task is provided in the Task Technical and Quality Assurance Plan (TTQAP), SRNL-RP-2011-00587. The specific objectives of this task were to: (1) Prepare and evaluate the SRR cooling coil grout identified in WSRC-STI-2008-00298 per the TTR for this work. The cooling coil grout is a mixture of BASF MasterFlow{reg_sign} 816 cable grout (67.67 wt. %), Grade 100 ground granulated blast furnace slag (7.52 wt. %) and water (24.81 wt. %); (2) Identify equipment grout placement and performance properties; (3) Design up to 2 additional grout systems for filling the Tank 18-F and Tank 19-F equipment; (4) Prepare samples of candidate grouts and measure fresh properties, thermal properties and cured properties; (5) Recommend a grout for the Tier 1A equipment fill mock up - ADMP 4 foot high mock up, 1 inch and 2 inch pipes; (6) Support procurement of materials for the Tier 1A equipment fill mock up test; (7) Prepare samples of the recommended grout for hydraulic property measurements which can be used for comparison to values used in the F- Tank Farm Performance Assessment (PA); and (8) Document equipment fill grout data and recommendations in a report.

Stefanko, D.; Langton, C.

2011-12-15T23:59:59.000Z

102

Facilities and Equipment for Genomics/Comparative Functional Genomics at New York University  

Science Conference Proceedings (OSTI)

This award was for partial support for the renovation of space to house research laboratories and moveable scientific equipment for genomics/functional geonomics at New York University.

Lennie, Peter

2006-06-29T23:59:59.000Z

103

Appliance and Equipment Energy Efficiency Standards | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Appliance and Equipment Energy Efficiency Standards Appliance and Equipment Energy Efficiency Standards Program Information Oregon Program Type ApplianceEquipment Efficiency...

104

Appliance and Equipment Energy Efficiency Standards | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

and Equipment Energy Efficiency Standards Appliance and Equipment Energy Efficiency Standards Program Information New York Program Type ApplianceEquipment Efficiency Standards ''...

105

Data Center Equipment | Open Energy Information  

Open Energy Info (EERE)

Center Equipment Jump to: navigation, search TODO: Add description List of Data Center Equipment Incentives Retrieved from "http:en.openei.orgwindex.php?titleDataCenterEquip...

106

Electrical Equipment Inventory and Inspection Information  

NLE Websites -- All DOE Office Websites (Extended Search)

Electrical Equipment Inventory and Inspection Information APS Non-NRTL Electrical Equipment Inventory Spreadsheet ANL Recognized Reputable Electrical Equipment Manufacturer List as...

107

Building Energy Software Tools Directory: Ground Loop Design  

NLE Websites -- All DOE Office Websites (Extended Search)

Ground Loop Design Ground Loop Design Ground Loop Design logo Ground Loop Design is a versatile ground source heat pump system design program that helps the trained geothermal HVAC designer/engineer size equipment, determine the correct lengths of bore or pipe required for commercial projects, optimize the piping configuration for balanced flow and optimal heat transfer, and calculate the annual and lifetime energy/operating/emissions costs associated with the design. The modular program enhances design productivity and permits flexibility in the designing process and customization based on designer preferences. It also has an English/metric conversion engine and is available in many languages, providing applicability to the widest range of equipment and customers. Screen Shots

108

Experience Based Seismic Equipment Qualification  

Science Conference Proceedings (OSTI)

This report provides guidelines that can be used to perform an experience-based seismic equipment qualification for verification of seismic adequacy of active electrical and mechanical equipment consistent with requirements of American Society of Civil Engineers (ASCE)-7. The report summarizes what requirements are sufficient to ensure that an item of equipment can perform its intended safety function after a design earthquake. The report also provides additional guidance on ensuring that an item of equi...

2007-12-21T23:59:59.000Z

109

Equipment Risk and Performance Assessment  

Science Conference Proceedings (OSTI)

Risk assessment and management are key elements in a well developed asset management implementation. Consequently an increasing number of utility managers are devoting resources to the task of improving their capabilities for risk-based decision making. Equipment risk models are essential elements in a risk assessment process. However, most proposed power delivery equipment risk models require for their successful application some probabilistic representation describing the chances of equipment ...

2012-12-14T23:59:59.000Z

110

Equipment Risk and Performance Assessment  

Science Conference Proceedings (OSTI)

Risk assessment and management are key elements in a well-developed asset management implementation. Consequently, an increasing number of utility managers are devoting resources to the task of improving their capabilities for risk-based decision making. Equipment risk models are essential elements in the risk assessment process. However, for their application, most proposed power delivery equipment risk models require some probabilistic representation describing the chances of equipment failure. This re...

2011-12-21T23:59:59.000Z

111

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

The comment period is closed. Milestones and Documents The direct heating equipment, residential water heaters, and pool heaters standby and off mode test procedures...

112

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Certification of Commercial Heating, Ventilating, Air-Conditioning, Refrigeration, and Water Heating Equipment Sign up for e-mail updates on regulations for this and other products...

113

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Amendments and Correction to Petitions for Waiver and Interim Waiver for Consumer Products and Commercial and Industrial Equipment Sign up for e-mail updates on regulations for...

114

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Information Collection on Commercial Equipment Labeling Sign up for e-mail updates on regulations for this and other products The Department of Energy is seeking information...

115

Summary of the Seismic Adequacy of Twenty Classes of Equipment Required for the Safe Shutdown of Nuclear Plants  

Science Conference Proceedings (OSTI)

This report is a response to the NRC's decision to address the concerns of Unresolved Safety Issue (USI) A-46 with seismic experience data to power plant equipment. The report defines 20 generic classes of nuclear plant equipment, describes a generic ground motion response spectrum for applicability of the seismic experience database, summarizes the basis for the seismic adequacy assessment and for each equipment class, defines sources of seismic damage for each class of equipment and explains the develo...

1991-07-01T23:59:59.000Z

116

Electrical Subsurface Grounding Analysis  

SciTech Connect

The purpose and objective of this analysis is to determine the present grounding requirements of the Exploratory Studies Facility (ESF) subsurface electrical system and to verify that the actual grounding system and devices satisfy the requirements.

J.M. Calle

2000-11-01T23:59:59.000Z

117

Ground Motion Studies at NuMI  

Science Conference Proceedings (OSTI)

Ground motion can cause significant deterioration in the luminosity of a linear collider. Vibration of numerous focusing magnets causes continuous misalignments, which makes the beam emittance grow. For this reason, understanding the seismic vibration of all potential LC sites is essential and related efforts in many sites are ongoing. In this document we summarize the results from the studies specific to Fermilab grounds as requested by the LC project leader at FNAL, Shekhar Mishra in FY04-FY06. The Northwestern group focused on how the ground motion effects vary with depth. Knowledge of depth dependence of the seismic activity is needed in order to decide how deep the LC tunnel should be at sites like Fermilab. The measurements were made in the NuMI tunnel, see Figure 1. We take advantage of the fact that from the beginning to the end of the tunnel there is a height difference of about 350 ft and that there are about five different types of dolomite layers. The support received allowed to pay for three months of salary of Michal Szleper. During this period he worked a 100% of his time in this project. That include one week of preparation: 2.5 months of data taking and data analysis during the full period of the project in order to guarantee that we were recording high quality data. We extended our previous work and made more systematic measurements, which included detailed studies on stability of the vibration amplitudes at different depths over long periods of time. As a consequence, a better control and more efficient averaging out of the daytime variation effects were possible, and a better study of other time dependences before the actual depth dependence was obtained. Those initial measurements were made at the surface and are summarized in Figure 2. All measurements are made with equipment that we already had (two broadband seismometers KS200 from GEOTECH and DL-24 portable data recorder). The offline data analysis took advantage of the full Fourier spectra information and the noise was properly subtracted. The basic formalism is summarized if Figure 3. The second objective was to make a measurement deeper under ground (Target hall, Absorber hall and Minos hall - 150 ft to 350 ft), which previous studies did not cover. All results are summarized in Figure 3 and 4. The measurements were covering a frequency range between 0.1 to 50 Hz. The data was taken continuously for at least a period of two weeks in each of the locations. We concluded that the dependence on depth is weak, if any, for frequencies above 1 Hz and not visible at all at lower frequencies. Most of the attenuation (factor of about 2-3) and damping of ground motion that is due to cultural activity at the surface is not detectable once we are below 150 ft underground. Therefore, accelerator currently under consideration can be build at the depth and there is no need to go deeper underground is built at Fermi National Laboratory.

Mayda M. Velasco; Michal Szleper

2012-02-20T23:59:59.000Z

118

Energy Basics: Supporting Equipment for Heating and Cooling Systems  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

for Heating and Cooling Systems Thermostats and ducts provide opportunities for saving energy. Dehumidifying heat pipes provide a way to help central air conditioners and heat...

119

Biomass Equipment & Materials Compensating Tax Deduction | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Biomass Equipment & Materials Compensating Tax Deduction Biomass Equipment & Materials Compensating Tax Deduction Eligibility Commercial Industrial Savings For Bioenergy Biofuels...

120

Building Technologies Office: Appliance and Equipment Standards...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

RESIDENTIAL BUILDINGS COMMERCIAL BUILDINGS APPLIANCE & EQUIPMENT STANDARDS BUILDING ENERGY CODES EERE Building Technologies Office Appliance & Equipment Standards...

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

After-hours Power Status of Office Equipment and Inventory of Miscellaneous Plug-load Equipment  

Science Conference Proceedings (OSTI)

This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of ''miscellaneous'' plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers. This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from twelve commercial buildings in California, Georgia, and Pennsylvania: two health care buildings, two large offices (> 500 employees each), three medium offices (50-500 employees), four education buildings, and one ''small office'' that is actually an aggregate of five small businesses. Two buildings are in the San Francisco Bay area of California, five are in Pittsburgh, Pennsylvania, and five are in Atlanta, Georgia.

Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Margaret J.; Busch, John F.

2004-01-22T23:59:59.000Z

122

2004 Equipment Reliability Forum Proceedings  

Science Conference Proceedings (OSTI)

This report describes the proceedings of the EPRI 2004 Equipment Reliability Forum that was held September 13–14, 2004, in Kansas City, Missouri. This annual forum provides an opportunity for industry personnel involved in equipment reliability and related issues to exchange information and share experiences. It is structured to incorporate both formal presentations and open discussion.

2004-11-30T23:59:59.000Z

123

Equipment Risk and Performance Assessment  

Science Conference Proceedings (OSTI)

This report introduces the basis for understanding, developing, and applying a new set of practical, condition-based risk models for substation equipment. Because of the great variety of risks encountered in the power delivery industry and the diversity in utility equipment and business practices, the focus at this stage of the project is at the conceptual level.

2010-12-23T23:59:59.000Z

124

GPHS-RTGs in support of the Cassini Mission. Semi annual technical progress report, 1 April 1996--29 September 1996  

SciTech Connect

This technical progress report discusses work on the Radioisotope Generators and Ancillary Activities for the Cassini spacecraft. The Cassini spacecraft is expected to launch in October 1997, and will explore Saturn and its moons. This progress report discusses issues in: spacecraft integration and liason, engineering support, safety, qualified unicouple fabrication, ETG fabrication and testing, ground support equipment, RTG shipping and launch support, designs, reviews and mission application. Safety analysis of the RTGs during reentry and launch accidents are covered. This report covers the period of April 1 to September 29, 1996.

NONE

1996-10-20T23:59:59.000Z

125

GPHS-RTGs in support of the CRAF/Cassini missions. Semi-annual technical report, 30 September 1991--29 March 1992  

DOE Green Energy (OSTI)

The technical progress achieved during the period 30 September 1911 through 29 March 1992 on Contract DE-AC03-91SF18852.000 Radioisotope Thermoelectric Generators and Ancillary Activities is described in this document. This report is organized by the program task structure as follows: spacecraft integration and liaison, engineering support, safety, qualified unicouple production, ETG fabrication, assembly and test, ground support equipment (GSE), RTG shipping and launch support, designs, reviews, and mission applications, project management, quality assurance, reliability, contract changes, and non-capital CAGO, and CAGO acquisition (Capital Funds).

Not Available

1992-04-20T23:59:59.000Z

126

GPHS-RTGs in support of the Cassini RTG Program. Semi annual technical progress report, September 26, 1994--April 2, 1995  

DOE Green Energy (OSTI)

The technical progress achieved during the period 26 September 1994 through 2 April 1995 on Contract DE-AC03-91SF18852 Radioisotope Thermoelectric Generators and Ancillary Activities is described herein. Monthly technical activity for the period 27 February 1995 through 2 April 1995 is included in this progress report. The report addresses tasks, including: spacecraft integration and liaison; engineering support; safety; qualified unicouple production; ETG Fabrication, assembly, and test; ground support equipment; RTG shipping and launch support; designs, reviews, and mission applications; project management, quality assurance, reliability, contract changes, CAGO acquisition (operating funds), and CAGO maintenance and repair; and CAGO acquisition (capital funds).

NONE

1995-04-20T23:59:59.000Z

127

Proceedings, 25th international conference on ground control in mining  

Science Conference Proceedings (OSTI)

Topics covered include: computer and physical modelling; geology in ground control; geophysics in ground control; ground control; impoundments stability; longwall gateroad support design; longwall operations; longwall shields and standing supports; mine design; multiple-seam mining interactions; pillar and pillar extraction; roof bolting; roof bolting - resin; and subsidence. Most of the topics include a retrospective paper which summarises the progress of the subject field during the past 25 years.

Peng, S.S.; Mark, C.; Finfinger, G.; Tadolini, S.; Wahab Khair, A.; Heasley, K.; Luo, Y. (eds.)

2006-07-01T23:59:59.000Z

128

Nuclear Maintenance Applications Center: Oil Lubrication Guide for Rotating Equipment  

Science Conference Proceedings (OSTI)

At a nuclear station, several types of safety-related and non-safety-related equipment rely on lubricating oil systems to provide lubrication to rotating components. These lubricating systems consist of gears, pumps, valves, heat exchangers, and other parts. In the event of a lubrication system failure, the supported equipment can be shut down, which in turn can lead to unanticipated entries into limiting conditions of operation, system degradation, or a unit trip. An understanding of how oil is affected...

2009-12-09T23:59:59.000Z

129

Equipment Reliability Site-Wide Training v1.0  

Science Conference Proceedings (OSTI)

The Equipment Reliability Site-Wide Training is a computer based training module that allows users to access training when desired and review it at their own pace. It provides graphics and interactive features to enhance learning. This training will support EPRInuclear utility members by raising awareness of personnel in various organizations as to their roles and responsibilities related to equipment reliability and focus attention on critical components and single point vulnerabilities within nuclear p...

2011-06-22T23:59:59.000Z

130

Accurate LPG analysis begins with sampling procedures, equipment  

SciTech Connect

Proper equipment and procedures are essential for obtaining representative samples from an LPG stream. This paper discusses how sampling of light liquid hydrocarbons generally involves one of two methods: flow- proportional composite sampling by a mechanical device or physical transfer of hydrocarbon fluids from a flowing pipeline or other source into a suitable portable sample container. If sampling by proper techniques and equipment supports careful chromatographic analysis, full advantage of accurate mass measurement of LPG can be realized.

Wilkins, C.M. (Koch Pipelines, Inc., Medford, OK (US))

1990-11-05T23:59:59.000Z

131

Solid waste burial grounds interim safety analysis  

SciTech Connect

This Interim Safety Analysis document supports the authorization basis for the interim operation and restrictions on interim operations for the near-surface land disposal of solid waste in the Solid Waste Burial Grounds. The Solid Waste Burial Grounds Interim Safety Basis supports the upgrade progress for the safety analysis report and the technical safety requirements for the operations in the Solid Waste Burial Grounds. Accident safety analysis scenarios have been analyzed based on the significant events identified in the preliminary hazards analysis. The interim safety analysis provides an evaluation of the operations in the Solid Waste Burial Grounds to determine if the radiological and hazardous material exposures will be acceptable from an overall health and safety standpoint to the worker, the onsite personnel, the public, and the environment.

Saito, G.H.

1994-10-01T23:59:59.000Z

132

Grounding and Lightning Protection of Capacitor Controllers  

Science Conference Proceedings (OSTI)

This is the third report in EPRI's capacitor reliability study. It deals with capacitor controller grounding and lightning protection. Prior reports dealt with nuisance fuse operations, operating and construction practices, and use of distribution line capacitors for transmission voltage support. Simulations were performed to investigate various controller mounting locations and grounding configurations and their impact on the magnitude of surges reaching the controller. Once these aspects of capacitor c...

2005-03-08T23:59:59.000Z

133

Tube support  

Science Conference Proceedings (OSTI)

A tube support for supporting horizontal tubes from an inclined vertical support tube passing between the horizontal tubes. A support button is welded to the vertical support tube. Two clamping bars or plates, the lower edges of one bearing on the support button, are removably bolted to the inclined vertical tube. The clamping bars provide upper and lower surface support for the horizontal tubes.

Mullinax, Jerry L. (Green Township, Summit County, OH)

1988-01-01T23:59:59.000Z

134

Electrical grounding prong socket  

SciTech Connect

The invention is a socket for a grounding prong used in a three prong electrical plug and a receptacle for the three prong plug. The socket being sufficiently spacious to prevent the socket from significantly stretching when a larger, U-shaped grounding prong is inserted into the socket, and having a ridge to allow a snug fit when a smaller tubular shape grounding prong is inserted into the socket.

Leong, Robert (Dublin, CA)

1991-01-01T23:59:59.000Z

135

Laboratory Equipment Donation Program - Guidelines  

Office of Scientific and Technical Information (OSTI)

The United States Department of Energy, in accordance with its The United States Department of Energy, in accordance with its responsibility to encourage research and development in the energy area, awards grants of used energy-related laboratory equipment. Universities, colleges and other non-profit educational institutions of higher learning in the United States are eligible to apply for equipment to use in energy-oriented educational programs in the life, physical, and environmental sciences, and in engineering. The equipment listed in this database is available for grant; however, specific items may be recalled for DOE use and become unavailable through the program. Frequently Asked Questions Who is eligible to apply for equipment? Any non-profit, educational institution of higher learning, such as a middle school, high school, university, college, junior college, technical

136

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Single Package Vertical Air Conditioners and Heat Pumps Single Package Vertical Air Conditioners and Heat Pumps Sign up for e-mail updates on regulations for this and other products Manufacturers have been required to comply with the Department of Energy's energy conservation standards for single package vertical air conditioners and heat pumps as a separate equipment class since 2008. Before 2010, this equipment was regulated under the broader scope of commercial air conditioning and heating equipment. Single package vertical air conditioners and heat pumps are commercial air conditioning and heating equipment with its main components arranged in a vertical fashion. They are mainly used in modular classrooms, modular office buildings, telecom shelters, and hotels, and are typically installed on the outside of an exterior wall or in a closet against an exterior wall but inside the building.

137

LANSCE | Lujan Center | Ancillary Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

Ancillary Equipment Ancillary Equipment For general questions, please contact the Lujan Center Sample Environments responsible: Victor Fanelli | vfanelli@lanl.gov | 505.667.8755 Sample and Equipment Shipping Instructions For questions regarding shipping procedures, contact Lujan Center Experiment Coordinator: Leilani Conradson | leilani@lanl.gov | 505.665.9505 Low Temperature Equipment Specifications Flight Path/Instrument Compatibility Responsible Displex closed-cycle refrigerators Tmin= 4 K to 12 K Tmax= 300 K to 340 K 11 - Asterix 04 - HIPPO 03 - HIPD 10 - LQD 02 - SMARTS Victor Fanelli vfanelli@lanl.gov Or particular instrument scientist Top loading closed-cycle refrigerator T = 10 K to 500 K option of in situ gas adsorption cell 07 - FDS Luke Daemon lld@lanl.gov Monika Hartl hartl@lanl.gov

138

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Direct Heating Equipment and Pool Heaters Active Mode Test Procedures Direct Heating Equipment and Pool Heaters Active Mode Test Procedures Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is proposing to amend the active mode test procedures for direct heating equipment and pool heaters. This rulemaking is mandated by the Energy Policy and Conservation Act (EPCA). Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a notice of proposed rulemaking regarding active mode test procedures for direct heating equipment and pool heaters. 78 FR 63410 (October 24, 2013). The comment deadline is January 7, 2014. Public Meeting Information

139

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

heaters, gas-fired and oil-fired instantaneous water heaters and hot water supply boilers, and unfired hot water storage tanks. Commercial water heating equipment is used to...

140

Commonwealth's Master Equipment Leasing Program  

Energy.gov (U.S. Department of Energy (DOE))

The [http://www.trs.virginia.gov/debt/MELP%20Guides.aspx Master Equipment Leasing Program] (MELP) ensures that all Commonwealth agencies, authorities and institutions obtain consistent and...

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

for automatic commercial ice-making equipment cover maximum energy use and maximum condenser water use of cube ice machines with harvest rates between 50 and 2,500 lbs of ice...

142

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Small, Large, and Very Large, Air-Cooled Commercial Air Conditioning and Heating Equipment Sign up for e-mail updates on regulations for this and other products Pursuant to Section...

143

Predaceous Ground Beetles  

E-Print Network (OSTI)

Predaceous ground beetles can be a nuisance to homeowners, especially when they are numerous. This publication describes the beetles and discusses ways to prevent and treat them.

Sansone, Chris; Minzenmayer, Rick

2003-06-30T23:59:59.000Z

144

Substation grounding programs  

SciTech Connect

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. This report, Volume 3, is a users manual and an installation and validation manual for the computer program SGSYS (Substation Grounding SYStem Analysis Program). This program analyzes the substation ground field given the total electric current injected into the ground field and the design of the grounding system. Standard outputs of the program are (1) total ground resistance, (2) step voltage, (3) touch voltage, (4) voltages on a grid of points, (5) voltage profile along straight lines, (6) transfer voltages, (7) ground potential rise, (8) body currents, (9) step voltage profile along straight lines, and (10) touch voltage profile along straight lines. This program can be utilized in an interactive or batch mode. In the interactive mode, the user defines the grounding system geometry, soil parameters, and output requests interactively, with the use of a user friendly conversational program. The users manual describes data requirements and data preparation procedures. An appendix provides forms which facilitate data collection procedures. The installation and validation manual describes the computer files which make up the program SGSYS and provides a test case for validation purposes.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

145

Water-Using Equipment: Domestic  

SciTech Connect

Water management is an important aspect of energy engineering. This article addresses water-using equipment primarily used for household purposes, including faucets, showers, toilets, urinals, dishwashers, and clothes washers, and focuses on how the equipment can be optimized to save both water and energy. Technology retrofits and operation and maintenance changes are the primary methods discussed for water and energy conservation. Auditing to determine current consumption rates is also described for each technology.

Solana, Amy E.; McMordie-Stoughton, Katherine L.

2006-01-24T23:59:59.000Z

146

History of Residential Grounding  

Science Conference Proceedings (OSTI)

This report describes the development of residential electrical service grounding practices in the United States. The report focuses on the history of the National Electrical Code (NEC), which prescribes standards for wiring practices in residences, including grounding of the building electrical service.

2002-09-19T23:59:59.000Z

147

Ways of grounding imagination  

Science Conference Proceedings (OSTI)

This paper discusses and evaluates use of different participatory design methods in relation to addressing the challenge of grounding imagination. It presents reflections on the use of three participatory design methods, deployed in the WorkSpace project: ... Keywords: PD methods, analytical triangulation, bricolage, future laboratory, grounding imagination, in-situ prototyping experiments

Monika Büscher; Mette Agger Eriksen; Jannie Friis Kristensen; Preben Holst Mogensen

2004-07-01T23:59:59.000Z

148

Permit for Charging Equipment Installation: Electric Vehicle Supply Equipment (EVSE)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Compliance with the following permit will allow the installation and operation of electric vehicle charging equipment at a Compliance with the following permit will allow the installation and operation of electric vehicle charging equipment at a residence in the City, State jurisdiction. This permit addresses one of the following situations: Only an additional branch circuit would be added at the residence A hard-wired charging station would be installed at the residence. The attached requirements for wiring the charging station are taken directly out of the 2011 edition of the National Electrical Code (NEC) NFPA 70, Article 625 Electric Vehicle Charging System. This article does not provide all of the information necessary for the installation of electric vehicle charging equipment. Please refer to the current edition of the electrical code adopted by the local jurisdiction for additional installation requirements. Reference to the 2011 NEC may be

149

Ground Motion Workshop  

NLE Websites -- All DOE Office Websites (Extended Search)

2nd Advanced ICFA Beam Dynamics Workshop 2nd Advanced ICFA Beam Dynamics Workshop on Ground Motion in Future Accelerators November 6 - 9, 2000 SLAC Coordinators: Andrei Seryi & Tor Raubenheimer Proceedings Updated June 26, 2001 Agenda and Presentations Workshop photos Summaries Useful links Poster Goals Introduction to the problems Structure Registration Registered participants Committees Location, Accommodations and Travel Workshop on Ground Motion in Future Accelerators A workshop was held at SLAC that was devoted to ground motion and its effects on future accelerators. Ground motion and vibration can be a limiting effect in synchrotron light sources, hadron circular colliders, and electron/positron linear colliders. Over the last several years, there has been significant progress in the understanding of the ground motion and its effects, however, there are

150

Tax Credit for Renewable Energy Equipment Manufacturers | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tax Credit for Renewable Energy Equipment Manufacturers Tax Credit for Renewable Energy Equipment Manufacturers Tax Credit for Renewable Energy Equipment Manufacturers < Back Eligibility Commercial Industrial Savings Category Bioenergy Solar Buying & Making Electricity Home Weatherization Water Heating & Cooling Swimming Pool Heaters Water Heating Commercial Heating & Cooling Heating Wind Maximum Rebate $20 million Program Info Expiration Date 1/1/2014 State Oregon Program Type Industry Recruitment/Support Rebate Amount 50% of eligible costs (10% per year for 5 years) Provider Oregon Business Development Department The Tax Credit for Renewable Energy Resource Equipment Manufacturing Facilities was enacted as a part of Oregon's Business Energy Tax Credit (BETC) in July 2007, with the passage of [http://www.leg.state.or.us/07reg/measpdf/hb3200.dir/hb3201.en.pdf HB

151

Energy efficiency standards for equipment: Additional opportunities...  

NLE Websites -- All DOE Office Websites (Extended Search)

efficiency standards for equipment: Additional opportunities in the residential and commercial sectors Title Energy efficiency standards for equipment: Additional opportunities in...

152

Building Technologies Office: Appliance and Equipment Standards...  

NLE Websites -- All DOE Office Websites (Extended Search)

Equipment Standards Result in Large Energy, Economic, and Environmental Benefits to someone by E-mail Share Building Technologies Office: Appliance and Equipment Standards Result...

153

Philadelphia Gas Works - Commercial and Industrial Equipment...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

available to all PGW commercial and industrial customers installing high efficiency boilers or eligible commercial food service equipment. All equipment must meet program...

154

Renewable Energy Equipment Exemption | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Renewable Energy Equipment Exemption Renewable Energy Equipment Exemption Eligibility Agricultural Commercial General PublicConsumer Residential Savings For Solar Buying & Making...

155

Laboratory Equipment Donation Program - LEDP Widget  

Office of Scientific and Technical Information (OSTI)

LEDP Widget You can access key features of the Laboratory Equipment Donation Program (LEDP) website by downloading the LEDP widget. Use the widget to search, view the equipment...

156

Commercial Refrigeration Equipment | Open Energy Information  

Open Energy Info (EERE)

Refrigeration Equipment Jump to: navigation, search TODO: Add description List of Commercial Refrigeration Equipment Incentives Retrieved from "http:en.openei.orgw...

157

Southwest Gas Corporation - Commercial Energy Efficient Equipment...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

offers rebates to commercial customers in Nevada who purchase energy efficient natural gas equipment. Eligible equipment includes clothes washers, storage water heaters, tankless...

158

Puerto Rico - Renewable Energy Equipment Certification | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Puerto Rico - Renewable Energy Equipment Certification Puerto Rico - Renewable Energy Equipment Certification Eligibility Construction InstallerContractor Savings For Solar Buying...

159

Appliances, Lighting, Electronics, and Miscellaneous Equipment...  

NLE Websites -- All DOE Office Websites (Extended Search)

Appliances, Lighting, Electronics, and Miscellaneous Equipment Electricity Use in New Homes Title Appliances, Lighting, Electronics, and Miscellaneous Equipment Electricity Use in...

160

METHOD OF LOCATING GROUNDS  

DOE Patents (OSTI)

ABS>This patent presents a method for locating a ground in a d-c circult having a number of parallel branches connected across a d-c source or generator. The complete method comprises the steps of locating the ground with reference to the mildpoint of the parallel branches by connecting a potentiometer across the terminals of the circuit and connecting the slider of the potentiometer to ground through a current indicating instrument, adjusting the slider to right or left of the mildpoint so as to cause the instrument to indicate zero, connecting the terminal of the network which is farthest from the ground as thus indicated by the potentiometer to ground through a condenser, impressing a ripple voltage on the circuit, and then measuring the ripple voltage at the midpoint of each parallel branch to find the branch in which is the lowest value of ripple voltage, and then measuring the distribution of the ripple voltage along this branch to determine the point at which the ripple voltage drops off to zero or substantially zero due to the existence of a ground. The invention has particular application where a circuit ground is present which will disappear if the normal circuit voltage is removed.

Macleish, K.G.

1958-02-11T23:59:59.000Z

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Ground water work breakdown structure dictionary  

SciTech Connect

This report contains the activities that are necessary to assess in ground water remediation as specified in the UMTRA Project. These activities include the following: site characterization; remedial action compliance and design documentation; environment, health, and safety program; technology assessment; property access and acquisition activities; site remedial actions; long term surveillance and licensing; and technical and management support.

NONE

1995-04-01T23:59:59.000Z

162

Equipment  

Science Conference Proceedings (OSTI)

...are becoming common, and the newer rectifier-inverter supplies are very compact and versatile. The inverter power supply consists of three converters: 60 Hz primary ac is rectified to dc. Direct current is inverted to high-frequency ac. Alternating current is rectified to dc....

163

Equipment  

Science Conference Proceedings (OSTI)

...The power source should be of a constant-current design. Transistorized power sources are most common, although inverter power supplies are also available. It should have a minimum open-circuit voltage of 80 V to ensure the reliable initiation

164

Equipment  

Science Conference Proceedings (OSTI)

...lined with natural rubber and acid-resistant red shale or carbon brick joined with silica-filled hot poured sulfur cement. [graphic]...

165

Equipment  

Science Conference Proceedings (OSTI)

Mar 15, 2012 ... To avoid production losses, reduce maintenance cost and increase safety reflexes of the crane operators in case of emergency, ECL™ has ...

166

Sustainability Support  

Energy.gov (U.S. Department of Energy (DOE))

Sustainability Support serves as a corporate technical assistance, coordination, and integration resource to support line organizations in the resolution of sustainability issues and management concerns.

167

Substation Grounding Grids  

Science Conference Proceedings (OSTI)

This report is an account of research performed by the Electric Power Research Institute (EPRI) in 2011 on the subject of degradation of buried grounding grids in electric power substations. Substation ground grids are usually made of copper conductors, which are placed below grade and are joined together and to the above-grade structures with various types of connectors. While above-grade connections are visible and may be inspected, below-grade connections are not visible or readily accessible for insp...

2011-12-22T23:59:59.000Z

168

EPRI Substation Grounding Project  

Science Conference Proceedings (OSTI)

The Electric Power Research Institute (EPRI) has been conducting research in the area of substation grounding and fault current management for several decades. This research has resulted in a large number of reports and other products. To help users locate the results of EPRI’s research in substation grounding and fault current management, an annual update is prepared containing brief descriptions of the products.ObjectiveThe objective of this report is ...

2012-09-06T23:59:59.000Z

169

System and Equipment Troubleshooting Guideline  

Science Conference Proceedings (OSTI)

This guideline outlines a generic process for use by power plant personnel engaged in the troubleshooting of plant systems and equipment. The structured approach presented in the guideline will be helpful for any plant personnel engaged in these activities, whether working individually or as part of a troubleshooting team.

2002-01-22T23:59:59.000Z

170

Photon Sciences Material Handling Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

Active Y Y Rhein Craig 20622 PSBC Active Y Y Page 3 of 80 List of Photon Sciences Mat'l Handling Equip 5242013 4:09:58 PM 725 UV East GE-56 PS-C01 Yale A-422-3749 2 ton...

171

Substation grounding programs  

SciTech Connect

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. This report, Volume 2, is a users manual and an installation and validation manual for the computer program SMECC (Substation Maximum Earth Current Computation Program). This program analyzes the electric current distribution among grounded structures inside and outside a substation for different fault conditions. The fault conditions are automatically selected by the program, or they may be specified by the user, or both. The fault condition resulting in maximum substation earth current is identified and reported. Data requirements for this program are: ground impedance, transformer data, transmission line data, transmission line grounding impedances, etc. The program provides four types of standard outputs: (1) a report of voltages and current flow in the unfaulted system, (2) a brief report of the maximum ground potential rise (worst fault condition), (3) a summary report of all fault conditions which have been analyzed by the program, and (4) a detailed report of voltages and current flow for a selected set of fault conditions.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

172

Some Observations on Corrosion of Support Systems in Selected ...  

Science Conference Proceedings (OSTI)

... dust and various particles, splashing of water and gases from the blasting and diesel equipment. Support components such as bolts, lattice, plate, retaining nut  ...

173

Energy-related laboratory equipment (ERLE) guidelines  

SciTech Connect

This document describes the Used Energy-Related Laboratory Equipment grants, and eligibility and procedures for participation. The document contains tables identifying typical equipment that may be requested, where to review ERLE equipment lists, and where to mail applications, a description of the eligible equipment grants access data system, and a copy of the ERLE grant application and instructions for its completion and submission.

Not Available

1995-01-01T23:59:59.000Z

174

Written Information Equipment TECHNOLOGY: Oral Information  

SCIENTIFIC OR TECHNOLOGICAL Equipment TECHNOLOGY: DEVELOPMENTAL RESOURCES Written Information Oral Information Hardware Facilities Data

175

Guide for Transmission Line Grounding  

Science Conference Proceedings (OSTI)

Electrical utilities have a duty to provide effective grounding for managing steady-state and fault currents, whether near a large generating station or at a remote distribution pole ground. For transmission lines, this imperative is usually met with investment in overhead ground wires and grounding electrodes. Effective grounding at each tower improves reliability8212by providing low path impedance to lightning strokes8212and contributes to safety. However, the fundamental physical parameters in ground ...

2007-12-20T23:59:59.000Z

176

Laboratory Equipment & Supplies | Sample Preparation Laboratories  

NLE Websites -- All DOE Office Websites (Extended Search)

Equipment & Supplies Equipment & Supplies John Bargar, SSRL Scientist Equipment is available to serve disciplines from biology to material science. All laboratories contain the following standard laboratory equipment: pH meters with standard buffers, analytical balances, microcentrifuges, vortex mixers, ultrasonic cleaning baths, magnetic stirrers, hot plates, and glassware. Most laboratories offer ice machines and cold rooms. Specialty storage areas for samples include a -80 freezer, argon and nitrogen glove boxes, radiation contamination areas, inert atmosphere chambers, and cold rooms. For specific information please see: Equipment Inventory Checkout Equipment & Supplies To view equipment inventory by laboratory, refer to the following pages: Biology Chemistry & Material Science Laboratory 1 Inventory

177

Simplified two layer model substation ground grid design methodology  

SciTech Connect

This paper presents a simplified approach to the design of substation ground grids in non-uniform soil conditions. The procedure is based on the interpretation of principles enunciated in the IEEE Standard 80-1986, with the supporting data having been obtained from actual field tests on substation ground grids.

Lazzara, J.; Barbeito, N. (Florida Power Corp., St. Petersburg, FL (USA))

1990-10-01T23:59:59.000Z

178

Proceedings, 24th international conference on ground control in mining  

Science Conference Proceedings (OSTI)

Topics covered: longwall mining; multiple seam mining; pillar/pillar extraction; surface subsidence; roof falls; geology; high horizontal stresses; highwall mining/slope stability; mine/roof support design; roof bolting; and detection of ground conditions.

Peng, S.S.; Mark, C.; Finfinger, G.; Tadolini, S.; Wahab Khair, A.; Heasley, K. (eds.) [West Virginia University, Morgantown, WV (United States)

2005-07-01T23:59:59.000Z

179

A Ground Validation Network for the Global Precipitation Measurement Mission  

Science Conference Proceedings (OSTI)

A prototype Validation Network (VN) is currently operating as part of the Ground Validation System for NASA’s Global Precipitation Measurement (GPM) mission. The VN supports precipitation retrieval algorithm development in the GPM prelaunch era. ...

Mathew R. Schwaller; K. Robert Morris

2011-03-01T23:59:59.000Z

180

Harbin Hafei Winwind Wind Power Equipment Co Ltd | Open Energy Information  

Open Energy Info (EERE)

Hafei Winwind Wind Power Equipment Co Ltd Hafei Winwind Wind Power Equipment Co Ltd Jump to: navigation, search Name Harbin Hafei-Winwind Wind Power Equipment Co Ltd Place Harbin, Heilongjiang Province, China Zip 150060 Sector Services, Wind energy Product Manufacturer of wind turbines. Provides installation and after-sale services and technology support. References Harbin Hafei-Winwind Wind Power Equipment Co Ltd[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Harbin Hafei-Winwind Wind Power Equipment Co Ltd is a company located in Harbin, Heilongjiang Province, China . References ↑ "Harbin Hafei-Winwind Wind Power Equipment Co Ltd" Retrieved from "http://en.openei.org/w/index.php?title=Harbin_Hafei_Winwind_Wind_Power_Equipment_Co_Ltd&oldid=346385"

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

BASIS Equipment | ORNL Neutron Sciences  

NLE Websites -- All DOE Office Websites (Extended Search)

Equipment Equipment BASIS Schematic Schematic of the SNS Backscattering Spectrometer. Helium dewer cooling a sample Helium dewer cooling a sample (bird's eye view). The heart of the work in a typical experiment is setting up the sample in the desired environment. A typical neutron sample ranging from a millimeter to a few centimeters is placed in a specialized cylindrical can and sealed. For liquids, the backscattering instrument often uses an annular can, created by placing a smaller can within a larger can and inserting the liquid sample between the two cans. This picture shows a helium dewer cooling the environment encompassing the sample can, which has been lowered into the beam from the top of the scattering tank. Crystals Crystals. The backscattering spectrometer is defined by the reflection of specific

182

Bulk Hauling Equipment for CHG  

NLE Websites -- All DOE Office Websites (Extended Search)

BULK HAULING EQUIPMENT FOR CHG BULK HAULING EQUIPMENT FOR CHG Don Baldwin Director of Product Development - Hexagon Lincoln HEXAGON LINCOLN TITAN(tm) Module System Compressed Hydrogen Gas * Capacity 250 bar - 616 kg 350 bar - 809 kg 540 bar - 1155 kg * Gross Vehicle Weight (with prime mover) 250 bar - 28 450 kg 350 bar - 30 820 kg 540 bar - 39 440 kg * Purchase Cost 250 bar - $510,000 350 bar - $633,750 540 bar - $1,100,000 Compressed Natural Gas * Capacity (250 bar at 15 C) - 7412 kg * GVW (With prime mover) - 35 250 kg * Purchase Cost (+/- 5%) - $510,000 HEXAGON LINCOLN TITAN(tm) V Magnum Trailer System Compressed Hydrogen Gas * Capacity 250 bar - 800 kg 350 bar - 1050 kg 540 bar - 1500 kg * Gross Vehicle Weight (with prime mover) 250 bar - 31 000 kg 350 bar - 34 200 kg 540 bar - 45 700 kg * Purchase Cost (+/-

183

COLD STORAGE DESIGN REFRIGERATION EQUIPMENT  

E-Print Network (OSTI)

COLD STORAGE DESIGN AND REFRIGERATION EQUIPMENT REFRIGERATION OF FISH - PART 1 \\ "..\\- ,,, T I Fishery Leaflet 427 Washington 25, D. C. June 1956 REFRIGERATION OF FISH - PART em; COlD STORAGE DESIGN · · · · · 18 Specific design features 0 0 · · · · · · · · · · · · · · 19 Refrigerated surfaces 0 · · 0 0 0 · 0

184

Technical Requirements and Vision for Development of an Integrated Framework for Substation Equipment Performance and Risk Assessment  

Science Conference Proceedings (OSTI)

The principal motivation for building an integrated assessment framework is to provide support for decisions that influence substation equipment performance. However, because equipment performance can in turn affect substation and system performance, the framework scope should reach beyond the traditional equipment boundaries. The decisions that revolve around maintenance and replacement most directly affect installed substation equipment performance and are therefore the primary focus of this work. Comp...

2008-12-18T23:59:59.000Z

185

Strategy Guideline: HVAC Equipment Sizing  

SciTech Connect

The heating, ventilation, and air conditioning (HVAC) system is arguably the most complex system installed in a house and is a substantial component of the total house energy use. A right-sized HVAC system will provide the desired occupant comfort and will run efficiently. This Strategy Guideline discusses the information needed to initially select the equipment for a properly designed HVAC system. Right-sizing of an HVAC system involves the selection of equipment and the design of the air distribution system to meet the accurate predicted heating and cooling loads of the house. Right-sizing the HVAC system begins with an accurate understanding of the heating and cooling loads on a space; however, a full HVAC design involves more than just the load estimate calculation - the load calculation is the first step of the iterative HVAC design procedure. This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

Burdick, A.

2012-02-01T23:59:59.000Z

186

Enhanced Methodologies for Equipment Modeling for Implementation in Asset Management and Smart Grid  

Science Conference Proceedings (OSTI)

Todays utility maintenance and asset managers need better information to support substation equipment investment decisions, and evolving utility perspectives have led to increased executive interest in new approaches to enable better management of power delivery equipment. As a consequence, there is a need for models and methodologies that can supply the information required to make well-informed maintenance and asset management decisions.

2009-12-23T23:59:59.000Z

187

Substation grounding programs  

SciTech Connect

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. This report, Volume 5, is an applications guide of the three computer programs. SOMIP, SMECC, and SGSYS, for the purpose of designing a safe substation grounding system. The applications guide utilizes four example substation grounding systems for the purpose of illustrating the application of the programs, SOMIP, SMECC, and SGSYS. The examples are based on data provided by four contributing utilities, namely, Houston Lighting and Power Company, Southern Company Services, Puget Sound Power and Light Company, and Arizona Public Service Company. For the purpose of illustrating specific capabilities of the computer programs, the data have been modified. As a result, the final designs of the four systems do not necessarily represent actual grounding system designs by these utilities. The example system 1 is a 138 kV/35 kV distribution substation. The example system 2 is a medium size 230 kV/115 kV transmission substation. The third example system is a generation substation while the last is a large 525 kV/345 kV/230 kV transmission substation. The four examples cover most of the practical problems that a user may encounter in the design of substation grounding systems.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

188

Used energy-related laboratory equipment grant program for institutions of higher learning. Eligible equipment catalog  

Science Conference Proceedings (OSTI)

This is a listing of energy related equipment available through the Energy-Related Laboratory Equipment Grant Program which grants used equipment to institutions of higher education for energy-related research. Information included is an overview of the program, how to apply for a grant of equipment, eligibility requirements, types of equipment available, and the costs for the institution.

Not Available

1994-07-01T23:59:59.000Z

189

Substation Ground Grid Impedance Measurement  

Science Conference Proceedings (OSTI)

Because safety impacts all segments of the electric power industry, the integrity and conformance to standards of substation grounding systems is of paramount importance. This report summarizes field demonstrations of commercially available meters for performance evaluation of large grounding systems, including the EPRI Ground Grid Evaluator (commercially known as the Smart Ground Multimeter or SGM).

2007-12-13T23:59:59.000Z

190

Department of Veterans Affairs, FONSI - Ground mounted solar photovoltaic  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ground mounted solar Ground mounted solar photovoltaic power at San Joaquin National Cemetery Department of Veterans Affairs, FONSI - Ground mounted solar photovoltaic power at San Joaquin National Cemetery An Environmental Assessment (EA) has been prepared under the direction of an interdisciplinary team analyzing theproposed construction of a Photovoltaic System at the San Joaquin National Cemetery (SNC) in San Joaquin,Calofornia. CX rulemaking files More Documents & Publications Department of Veterans Affairs, FONSI - Rooftop solar PV power at Calverton National Cemetery Department of Energy Technical Support Document National Environmental Policy Act Implementing Procedures Supplement to Notice of Proposed Rulemaking Proposed Changes and Supplemental Supporting Basis

191

SUPPORTING CALCULATIONS FOR SUBMERGED BED SCRUBBER CONDENSATE DISPOSAL PRECONCEPTUAL STUDY  

Science Conference Proceedings (OSTI)

This document provides supporting calculations for the preparation of the Submerged Bed Scrubber Condensate Disposal Pre conceptual Study report The supporting calculations include equipment sizing, Hazard Category determination, and LAW Melter Decontamination Factor Adjustments.

PAJUNEN AL; TEDESCHI AR

2012-09-18T23:59:59.000Z

192

Supporting Calculations For Submerged Bed Scrubber Condensate Disposal Preconceptual Study  

SciTech Connect

This document provides supporting calculations for the preparation of the Submerged Bed Scrubber Condensate Disposal Preconceptual Study report The supporting calculations include equipment sizing, Hazard Category determination, and LAW Melter Decontamination Factor Adjustments.

Pajunen, A. J.; Tedeschi, A. R.

2012-09-18T23:59:59.000Z

193

Improved Smart Ground Multimeter  

Science Conference Proceedings (OSTI)

The Smart Ground Multimeter (SGM) underwent three major redesigns since its original development in the early 1980s. This report describes the latest redesign and provides useful tips on the assessment of measured data quality and on resolving measurement problems in the field.

2006-12-18T23:59:59.000Z

194

Substation grounding programs  

SciTech Connect

The five volume report comprises the user manual, installation, and validation manual and an applications guide for the SGA (Substation Grounding Analysis) software package. SGA consists of four computer programs: (1) SOMIP, (2) SMECC, (3) SGSYS, and (4) TGRND. The first three programs provide a comprehensive analysis tool for the design of substation grounding systems to meet safety standards. The fourth program, TGRND, provides a state of the art analysis tool for computing transient ground potential rise and ground system impedance. This part of the report, Volume 1, is a users manual and an installation and validation manual for the computer program SOMIP (SOil Measurement Interpretation Program). This program computes the best estimate of the parameters of a two layer soil model from usual soil resistivity measurements. Four pin or three pin soil measurements can be accommodated. In addition, it provides error bounds on the soil parameters for a given confidence level. The users manual describes data requirements and data preparation procedures. The installation and validation manual describes the computer files which make up the program SOMIP and provides two test cases for validation purposes. 4 refs.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). School of Electrical Engineering)

1992-05-01T23:59:59.000Z

195

Remote Handling Equipment for a High-Level Waste Waste Package Closure System  

SciTech Connect

High-level waste will be placed in sealed waste packages inside a shielded closure cell. The Idaho National Laboratory (INL) has designed a system for closing the waste packages including all cell interior equipment and support systems. This paper discusses the material handling aspects of the equipment used and operations that will take place as part of the waste package closure operations. Prior to construction, the cell and support system will be assembled in a full-scale mockup at INL.

Kevin M. Croft; Scott M. Allen; Mark W. Borland

2006-04-01T23:59:59.000Z

196

Workshop on environmental qualification of electric equipment  

SciTech Connect

Questions concerning the Environmental Qualification (EQ) of electrical equipment used in commercial nuclear power plants have recently become the subject of significant interest to the US Nuclear Regulatory Commission (NRC). Initial questions centered on whether compliance with the EQ requirements for older plants were adequate to support plant operation beyond 40 years. After subsequent investigation, the NRC Staff concluded that questions related to the differences in EQ requirements between older and newer plants constitute a potential generic issue which should be evaluated for backfit, independent of license renewal activities. EQ testing of electric cables was performed by Sandia National Laboratories (SNL) under contract to the NRC in support of license renewal activities. Results showed that some of the environmentally qualified cables either failed or exhibited marginal insulation resistance after a simulated plant life of 20 years during accident simulation. This indicated that the EQ process for some electric cables may be non-conservative. These results raised questions regarding the EQ process including the bases for conclusions about the qualified life of components based upon artificial aging prior to testing.

Lofaro, R.; Gunther, W.; Villaran, M.; Lee, B.S.; Taylor, J. [comps.] [Brookhaven National Lab., Upton, NY (United States)

1994-05-01T23:59:59.000Z

197

AAO support observations for the Hubble Deep Field Sout  

E-Print Network (OSTI)

We present proposed ground-based support observations at the AAO for the forthcoming Hubble Deep Field South (HDF-S) campaign.

B. J. Boyle

1998-04-09T23:59:59.000Z

198

Fire suppression and detection equipment  

SciTech Connect

Inspection and testing guidelines go beyond the 'Code of Federal Regulation'. Title 30 of the US Code of Federal Regulations (30 CFR) contains requirements and references to national standards for inspection, testing and maintenance of fire suppression and detection equipment for mine operators. However, federal requirements have not kept pace with national standards and best practices. The article lists National Fire Protection (NFPA) standards that are referenced by the US Mine Safety and Health Administration (MSHA) in 30 CFR. It then discusses other NFPA Standards excluded from 30 CFR and explains the NFPA standard development process. 2 refs., 3 tabs., 5 photos.

E.E. Bates [HSB Professional Loss Control, Lexington, KY (United States)

2006-01-15T23:59:59.000Z

199

Laboratory Equipment Donation Program - Application Process  

Office of Scientific and Technical Information (OSTI)

Equipment listings on the LEDP web site are obtained from the U.S. General Equipment listings on the LEDP web site are obtained from the U.S. General Services Administration (GSA) Energy Asset Disposal System (EADS). Once equipment is listed, EADS allows 30 days for grantees from eligible institutions to apply for it on the LEDP site. Equipment Condition Codes are found near the top of the "LEDP Equipment Information" page for each item. The condition of equipment is graded as follows: 1: Unused Good Condition 4: Used Good Condition 7: Repairable Requires Repairs X: Salvage Salvage S: Scrap Scrap Specific questions concerning equipment should be directed to the point of contact responsible for the item(s) under consideration. This information is listed on the "Equipment Information" page, as well as on the grant

200

Abatement of Air Pollution: Air Pollution Control Equipment and Monitoring Equipment Operation (Connecticut)  

Energy.gov (U.S. Department of Energy (DOE))

These regulations contain instructions for the operation and monitoring of air pollution control equipment, as well as comments on procedures in the event of equipment breakdown, failure, and...

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Renewable Energy Equipment Manufacturer Tax Credit | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Manufacturer Tax Credit Renewable Energy Equipment Manufacturer Tax Credit Eligibility Commercial Industrial Savings For Bioenergy Biofuels Alternative Fuel Vehicles Commercial...

202

Appliances and Commercial Equipment Standards: Guidance  

NLE Websites -- All DOE Office Websites (Extended Search)

Office HOME ABOUT ENERGY EFFICIENT TECHNOLOGIES RESIDENTIAL BUILDINGS COMMERCIAL BUILDINGS APPLIANCE & EQUIPMENT STANDARDS BUILDING ENERGY CODES EERE Building Technologies...

203

Improved Thermal Modeling Tools for Substation Equipment  

Science Conference Proceedings (OSTI)

The ratings of substation terminal equipment often limit power flow through transmission circuits. Capital investment in terminal equipment is generally modest in comparison to lines, transformers, and underground cables. Replacement difficulties are centered more on service availability than on cost. Detailed manufacturer test data is often unavailable for older equipment but ratings are simpler to calculate than for lines. Certain types of terminal equipment are tolerant of over-loading and problems in...

2007-03-08T23:59:59.000Z

204

Equipment-Immunity Performance Guidelines: 2010 Activities  

Science Conference Proceedings (OSTI)

This report details EPRI’s 2010 efforts for improved equipment-immunity standards and performance in the electrical environment.

2010-12-16T23:59:59.000Z

205

Liquid-Liquid Extraction Equipment  

Science Conference Proceedings (OSTI)

Solvent extraction processing has demonstrated the ability to achieve high decontamination factors for uranium and plutonium while operating at high throughputs. Historical application of solvent extraction contacting equipment implies that for the HA cycle (primary separation of uranium and plutonium from fission products) the equipment of choice is pulse columns. This is likely due to relatively short residence times (as compared to mixer-settlers) and the ability of the columns to tolerate solids in the feed. Savannah River successfully operated the F-Canyon with centrifugal contactors in the HA cycle (which have shorter residence times than columns). All three contactors have been successfully deployed in uranium and plutonium purification cycles. Over the past 20 years, there has been significant development of centrifugal contactor designs and they have become very common for research and development applications. New reprocessing plants are being planned in Russia and China and the United States has done preliminary design studies on future reprocessing plants. The choice of contactors for all of these facilities is yet to be determined.

Jack D. Law; Terry A. Todd

2008-12-01T23:59:59.000Z

206

Seismic Studies of Substation Equipment: Progress Report  

Science Conference Proceedings (OSTI)

IEEE Standard 693, Recommended Practice for Seismic Design of Substations, is used by electric power utilities to qualify substation equipment for seismic movements. Deficiencies exist in the present standard, and information is unavailable for dynamic response that may be used to better analyze equipment and permit equipment evaluation in case of limited configuration changes, such as insulator substitution.

2009-09-28T23:59:59.000Z

207

Proceedings: Tenth EPRI Substation Equipment Diagnostics Conference  

SciTech Connect

Advanced monitoring and diagnostic sensors and systems are needed to provide reliable and accurate information for determining the condition of major transmission substation equipment. The tenth EPRI Substation Equipment Diagnostics Conference highlighted the work of researchers, universities, manufacturers, and utilities in producing advanced monitoring and diagnostic equipment for substations.

None

2002-06-01T23:59:59.000Z

208

Proceedings: Substation Equipment Diagnostics Conference IX  

SciTech Connect

Advanced monitoring and diagnostic sensors and systems are needed to provide reliable and accurate information for determining the condition of major transmission substation equipment. The ninth EPRI Substation Equipment Diagnostics Conference highlighted the work of researchers, universities, manufacturers, and utilities in producing advanced monitoring and diagnostic equipment for substations.

None

2001-09-01T23:59:59.000Z

209

Proceedings: Substation Equipment Diagnostics Conference VIII  

SciTech Connect

Advanced monitoring and diagnostic sensors and systems are needed to provide reliable and accurate information for determining the condition of major transmission substation equipment. The eighth EPRI Substation Equipment Diagnostics Conference highlighted the work of researchers, universities, manufacturers, and utilities in producing advanced monitoring and diagnostic equipment for substations.

None

2000-06-01T23:59:59.000Z

210

Guide to Energy-Efficient Office Equipment  

Science Conference Proceedings (OSTI)

Office equipment directly consumes as much as 30 billion kilowatt-hours of electricity, which represents 5% of total commercial electric energy consumption. EPRI's Guide to Energy-Efficient Office Equipment discusses the energy cost savings and environmental benefits of using high-efficiency equipment in areas ranging from personal computers and monitors to printers, copiers, and facsimile machines.

1996-04-05T23:59:59.000Z

211

Proceedings: Tenth EPRI Substation Equipment Diagnostics Conference  

Science Conference Proceedings (OSTI)

Advanced monitoring and diagnostic sensors and systems are needed to provide reliable and accurate information for determining the condition of major transmission substation equipment. The tenth EPRI Substation Equipment Diagnostics Conference highlighted the work of researchers, universities, manufacturers, and utilities in producing advanced monitoring and diagnostic equipment for substations.

2002-06-27T23:59:59.000Z

212

Electric Vehicle Supply Equipment (EVSE) Test and Evaluation  

Science Conference Proceedings (OSTI)

Deployment of electric vehicle supply equipment (EVSE) to support the electrification of transportation continues worldwide. In the United States alone, thousands of EVSEs have been deployed over the last year. EVSE hardware is designed to safely provide AC or DC power to plug-in electric vehicles in both commercial and residential spaces. More than 40 vendors have been identified that manufacture EVSE products for the North American market. EPRI has performed laboratory evaluations for a ...

2012-12-31T23:59:59.000Z

213

Ground State Entanglement Energetics  

E-Print Network (OSTI)

We consider the ground state of simple quantum systems coupled to an environment. In general the system is entangled with its environment. As a consequence, even at zero temperature, the energy of the system is not sharp: a projective measurement can find the system in an excited state. We show that energy fluctuation measurements at zero temperature provide entanglement information. For two-state systems which exhibit a persistent current in the ground state, energy fluctuations and persistent current fluctuations are closely related. The harmonic oscillator serves to illustrate energy fluctuations in a system with an infinite number of states. In addition to the energy distribution we discuss the energy-energy time-correlation function in the zero-temperature limit.

M. Buttiker; A. N. Jordan

2005-01-04T23:59:59.000Z

214

CEUS Ground Motion Project  

Science Conference Proceedings (OSTI)

Three utilities are currently pursuing early site permits (ESPs) for possible siting of new nuclear power plant facilities in the central and eastern United States (CEUS). The geological, seismological, and engineering characteristics of a site and its environs must be investigated in sufficient scope and detail. These investigations are needed to adequately evaluate a proposed site and to provide sufficient information for estimating the site's safe shutdown earthquake (SSE) ground motion. Nuclear Regul...

2003-12-02T23:59:59.000Z

215

Ground Squirrels and Gophers  

NLE Websites -- All DOE Office Websites (Extended Search)

Squirrels and Gophers Squirrels and Gophers Nature Bulletin No. 224-A April 2, 1966 Forest Preserve District of Cook County Seymour Simon, President Roland F. Eisenbeis, Supt. of Conservation GROUND SQUIRRELS AND GOPHERS On sunny summer days, a dusty-colored animal with yellowish and brown stripes, about the size of a small rat, often may be noticed creeping through the grass of prairies, pastures, golf courses or lawns. Watch him. He pauses every few feet to sit up, look and listen for a moment. Nervous and timid, he crouches low at every distant sound or passing shadow. Startle him and he scurries away, and then may suddenly halt and freeze, bolt upright, as stiff and straight as a stake driven in the ground. If approached, he gives a loud shrill trilling whistle and, with a flip of his tail, pops out of sight. Watch that spot closely and, in less than a minute, a snaky head appears. Be quiet. He has many enemies above ground and he also has a lot of curiosity. Presently he sits up upon his haunches again.

216

NFRC Support  

NLE Websites -- All DOE Office Websites (Extended Search)

NFRC Technical Support Founded in 1989, the National Fenestration Rating Council (NFRC) is a non-profit, publicprivate partnership which develops and administers a fair, accurate,...

217

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Alternative Efficiency Determination Methods and Alternate Rating Methods Alternative Efficiency Determination Methods and Alternate Rating Methods Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is proposing to revise and expand its existing regulations governing the use of alternative efficiency determination methods (AEDM) and alternate rating methods (ARM) for covered products as alternatives to testing for the purpose of certifying compliance. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a final rule revising its existing regulations governing the use of particular methods as alternatives to testing for commercial heating, ventilating, air conditioning, water heating, and refrigeration equipment. 78 FR 79579 (December 31, 2013).

218

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Illuminated Exit Signs Illuminated Exit Signs Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of illuminated exit signs since 2005. Illuminated exit signs are used to indicate exit doors in schools, hospitals, libraries, government buildings, and commercial buildings of all kinds, including offices, restaurants, stores, auditoriums, stadiums, and movie theatres. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates There are no recent updates for this equipment. Standards for Illuminated Exit Signs The following content summarizes the energy conservation standards for illuminated exit signs. The text is not an official reproduction of the Code of Federal Regulations and should not be used for legal research or citation.

219

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Warm Air Furnaces Commercial Warm Air Furnaces Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of commercial warm air furnaces since 1994. Commercial warm air furnaces are self-contained oil-fired or gas-fired furnaces that are designed to supply heated air through ducts to spaces that require it. Commercial warm air furnaces are industrial equipment and have a maximum rated input capacity of 225,000 British thermal units (Btu) an hour or more. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates DOE published a request for information regarding energy conservation standards for commercial warm air furnaces. 78 FR 25627 (May 2, 2013). For more information, please see the rulemaking webpage.

220

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial and Industrial Pumps Commercial and Industrial Pumps Sign up for e-mail updates on regulations for this and other products Pumps are used in agriculture, oil and gas production, water and wastewater, manufacturing, mining, and commercial building systems. Currently there are no energy conservation standards for pumps. The Department of Energy (DOE) will conduct an analysis of the energy use, emissions, costs, and benefits associated with this equipment during the commercial and industrial pumps energy conservation standards rulemaking. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates DOE published a notice of public meeting and availability of the framework document. 78 FR 7304 (Feb. 1, 2013). For more information, please see the rulemaking page.

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial and Industrial Compressors Determination Commercial and Industrial Compressors Determination Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) proposes to determine that commercial and industrial compressors meet the criteria for covered equipment under Part A-1 of Title III of the Energy Policy and Conservation Act (EPCA), as amended. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a Proposed Coverage Determination concerning commercial and industrial compressors. 77 FR 76972 (Dec. 31, 2012). Public Meeting Information No public meeting is scheduled at this time. Submitting Public Comments The comment period is closed.

222

Solar Equipment Certification | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Equipment Certification Solar Equipment Certification Solar Equipment Certification < Back Eligibility Construction General Public/Consumer Savings Category Solar Buying & Making Electricity Heating & Cooling Water Heating Program Info State Florida Program Type Equipment Certification Provider Florida Solar Energy Center Under the Solar Energy Standards Act of 1976, the Florida Solar Energy Center (FSEC) is responsible for certifying all solar equipment sold in Florida. A manufacturer who wishes to have their solar equipment certified first contacts FSEC for an application and requests that FSEC test samples of the product at random. Equipment is then subjected to a series of tests in order to be approved or denied certification. Standards and applications procedures for specific technologies are available on the FSEC web site.

223

Laboratory Equipment Donation Program - Contact Us  

Office of Scientific and Technical Information (OSTI)

End of Year Reports End of Year Reports At the end of the first year of using LEDP grant equipment, the grantee must provide DOE with a report on the use of the equipment. If a grantee does not submit a report, the DOE OPMO who approved the grant application can pull the equipment back, or not allow that institution to apply for more equipment. The report should describe: Any new courses instituted as a result of the grant of the equipment; Existing courses which have been expanded as a result of the grant of the equipment; Research activities, e.g., thesis titles, journals articles, sponsored research, etc.; and Other ways the equipment has been used to enhance courses, e.g., experiments, demonstrations, etc. If your item control Number starts with Send your report to 890565

224

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Distribution Transformers Distribution Transformers Sign up for e-mail updates on regulations for this and other products A distribution transformer provides the final voltage transformation in the electric power distribution system by reducing the high voltage of electric current from a power line to a lower voltage for use in a building. The Department of Energy (DOE) has regulated the energy efficiency level of low-voltage dry-type distribution transformers since 2007, and liquid-immersed and medium-voltage dry-type distribution transformers since 2010. A distribution transformer designed and constructed to be mounted on a utility pole is referred to as a pole-mount transformer. A distribution transformer designed and constructed to be located at ground level or underground, mounted on a concrete pad, and locked in a steel case is referred to as a pad-mount transformer.

225

Treading New Ground  

Science Conference Proceedings (OSTI)

At first glance, it might seem odd to find a nuclear weapons lab and a major tire company working together. However, a common interest in nonlinear dynamics and computational mechanics, together withforward-looking, supportive management, has brought ...

Nancy Forbes

2002-09-01T23:59:59.000Z

226

Supporting Statement:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Supporting Statement: Supporting Statement: OE Recovery Act Financial Assistance Grants OMB Control Number 1910-5149 This supporting statement provides additional information regarding the Department of Energy (DOE) request for processing of the renewal of the proposed information collection, OE Recovery Act Financial Assistance Grants. The numbered questions correspond to the order shown on the Office of Management and Budget (OMB) Form 83-I, "Instructions for Completing OMB Form 83-I." 1. Explain the circumstances that make the collection of information necessary. The Department of Energy (DOE) requires collection of information for Recovery Act Smart Grid grants. Sections 1304 and 1306 of the Energy Independence and Security Act

227

Pipe support  

DOE Patents (OSTI)

A pipe support for high temperature, thin-walled piping runs such as those used in nuclear systems. A section of the pipe to be supported is encircled by a tubular inner member comprised of two walls with an annular space therebetween. Compacted load-bearing thermal insulation is encapsulated within the annular space, and the inner member is clamped to the pipe by a constant clamping force split-ring clamp. The clamp may be connected to pipe hangers which provide desired support for the pipe.

Pollono, Louis P. (Hempfield Township, Hempfield County, PA)

1979-01-01T23:59:59.000Z

228

Southwest Gas Corporation - Commercial High-Efficiency Equipment...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

who purchase energy efficient natural gas equipment. Eligible equipment includes natural gas storage and tankless water heaters, boiler equipment, griddles, fryers, conveyor ovens,...

229

Better Buildings Alliance Equipment Performance Specifications  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

BBA Equipment Performance BBA Equipment Performance Specifications William Goetzler Navigant Consulting william.goetzler@navigant.com (781) 270 8351 April 4, 2013 Better Buildings Alliance BTO Program Review 2 | Building Technologies Office eere.energy.gov Project Overview The BBA Performance Specifications project provides information and tools to help BBA members and other commercial building owners/operators specify and purchase high efficiency equipment. - Ensures targeted technologies are of interest to end users and manufacturers

230

Survey of Substation Equipment Access Control Policies  

Science Conference Proceedings (OSTI)

Utility management and control of access to substations and equipment can help prevent not only unauthorized access by outside agents with ill intent, but also erroneous access to, or erroneous operation of, utility equipment by utility personnel.  This report provides the results of an EPRI–sponsored research project to identify how utilities manage access to transmission and distribution substations and equipment. BackgroundThe enhanced ...

2012-11-20T23:59:59.000Z

231

Better Buildings Alliance Equipment Performance Specifications  

NLE Websites -- All DOE Office Websites (Extended Search)

BBA Equipment Performance BBA Equipment Performance Specifications William Goetzler Navigant Consulting william.goetzler@navigant.com (781) 270 8351 April 4, 2013 Better Buildings Alliance BTO Program Review 2 | Building Technologies Office eere.energy.gov Project Overview The BBA Performance Specifications project provides information and tools to help BBA members and other commercial building owners/operators specify and purchase high efficiency equipment. - Ensures targeted technologies are of interest to end users and manufacturers

232

Reduce Radiation Losses from Heating Equipment  

Science Conference Proceedings (OSTI)

This DOE Industrial Technologies Program tip sheet describes how to save energy and costs by reducing expensive heat losses from industrial heating equipment, such as furnaces.

Not Available

2006-01-01T23:59:59.000Z

233

MOV surge arresters: improved substation equipment protection  

Science Conference Proceedings (OSTI)

The introduction of metal-oxide-varistor (MOV) surge arresters has added a new dimension to substation equipment protection. Through the optimal use of these arresters, it is possible to lower surge arrester ratings and thereby improve protective margins, resulting in a possible reduction of the insulation levels (BIL) of substation equipment. This reduction in BIL can lead to a significant reduction in the cost of substation equipment. General methods are delineated for selecting MOV surge arresters for substation protection and the resulting effect on substation equipment insulation levels.

Niebuhr, W.D.

1985-07-01T23:59:59.000Z

234

Schools - Electronic Equipment Damage Due to Lightning  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents the investigation of damage to a school's phone equipment, security alarm, and network computer system during a lightning storm.

2003-12-31T23:59:59.000Z

235

PPP Equipment Corporation | Open Energy Information  

Open Energy Info (EERE)

PPP Equipment Corporation Sector Solar Product PPP-E designs, produces and markets Chemical Vapor Deposition (CVD) reactors and converter systems producing high-purity...

236

Zhongneng Windpower Equipments | Open Energy Information  

Open Energy Info (EERE)

manufacturer engages in the development, design, testing and products manufacture of rotor blade of WTGS. References Zhongneng Windpower Equipments1 LinkedIn Connections...

237

Laboratory Equipment Donation Program - Contact Us  

Office of Scientific and Technical Information (OSTI)

Contact Us If you have a question about the Laboratory Equipment Donation Program (LEDP), we recommend you check frequently asked questions. If your question still has not been...

238

The Healthcare and Medical Equipment Industry  

Science Conference Proceedings (OSTI)

This PQ TechWatch highlights the measures that the healthcare and medical equipment industry is taking to reduce power quality (PQ) and electromagnetic compatibility (EMC) problems.

2003-12-31T23:59:59.000Z

239

Agricultural Lighting and Equipment Rebate Program (Vermont)...  

Open Energy Info (EERE)

with form History Share this page on Facebook icon Twitter icon Agricultural Lighting and Equipment Rebate Program (Vermont) This is the approved revision of this page, as...

240

Request an Inspection of User Electrical Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

date, time, and location of the inspection Equipment list and description List any manualsdocumentationschematics that exist and are present to aid with the inspection. A...

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

WEAR RESISTANT ALLOYS FOR COAL HANDLING EQUIPMENT  

E-Print Network (OSTI)

Proceedings of the Conference on Coal Feeding Systems, HeldWear Resistant Alloys for Coal Handling Equipment", proposalWear Resistant Alloys for Coal Handling Equi pment". The

Bhat, M.S.

2011-01-01T23:59:59.000Z

242

Stangl Semiconductor Equipment AG | Open Energy Information  

Open Energy Info (EERE)

Solar Product German manufacturer of wet chemistry systems for processing silicon and thin-film solar cells. References Stangl Semiconductor Equipment AG1 LinkedIn...

243

Equips Nucleares SA | Open Energy Information  

Open Energy Info (EERE)

Nucleares, SA Place Madrid, Spain Zip 28006 Sector Services Product ENSA is a Spanish nuclear components and nuclear services supply company. References Equips Nucleares, SA1...

244

APS Guideline for Personal Protective Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

severe consequences. Consequently, the CAT has adopted the following policies and procedures to ensure the proper selection and use of such equipment by CATXSD personnel...

245

Electric Vehicle Supply Equipment (EVSE) Testing  

NLE Websites -- All DOE Office Websites (Extended Search)

Electric Vehicle Supply Equipment (EVSE) Testing What's New PLUGLESS Level 2 EV Charging System by Evatran Group Inc. - August 2013 The Advanced Vehicle Testing Activity is tasked...

246

Solar Equipment Certification | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Equipment Certification Solar Equipment Certification Solar Equipment Certification < Back Eligibility Commercial Construction Installer/Contractor Residential Savings Category Heating & Cooling Commercial Heating & Cooling Solar Heating Water Heating Program Info State Minnesota Program Type Equipment Certification Provider Minnesota Department of Commerce Minnesota law requires that all active solar space-heating and water-heating systems, sold, offered for sale, or installed on residential and commercial buildings in the state meet Solar Rating and Certification Corporation (SRCC) standards. Specifically, the rule references SRCC's "Operating Guidelines" pertaining to collector certification and system certification: OG-100 and OG-300, respectively. Local building officials

247

Enclosed ground-flare incinerator  

DOE Patents (OSTI)

An improved ground flare is provided comprising a stack, two or more burner assemblies, and a servicing port so that some of the burner assemblies can be serviced while others remain in operation. The burner assemblies comprise a burner conduit and nozzles which are individually fitted to the stack's burner chamber and are each removably supported in the chamber. Each burner conduit is sealed to and sandwiched between a waste gas inlet port and a matching a closure port on the other side of the stack. The closure port can be opened for physically releasing the burner conduit and supplying sufficient axial movement room for extracting the conduit from the socket, thereby releasing the conduit for hand removal through a servicing port. Preferably, the lower end of the stack is formed of one or more axially displaced lower tubular shells which are concentrically spaced for forming annular inlets for admitting combustion air. An upper tubular exhaust stack, similarly formed, admits additional combustion air for increasing the efficiency of combustion, increasing the flow of exhausted for improved atmospheric dispersion and for cooling the upper stack.

Wiseman, Thomas R. (Calgary, CA)

2000-01-01T23:59:59.000Z

248

Hanford Site ground-water monitoring for 1994  

SciTech Connect

This report presents the results of the Ground-Water Surveillance Project monitoring for calendar year 1994 on the Hanford Site, Washington. Hanford Site operations from 1943 onward produced large quantities of radiologic and chemical waste that have impacted ground-water quality on the Site. Monitoring of water levels and ground-water chemistry is performed to track the extent of contamination and trends in contaminant concentrations. The 1994 monitoring was also designed to identify emerging ground-water quality problems. The information obtained is used to verify compliance with applicable environmental regulations and to evaluate remedial actions. Data from other monitoring and characterization programs were incorporated to provide an integrated assessment of Site ground-water quality. Additional characterization of the Site`s geologic setting and hydrology was performed to support the interpretation of contaminant distributions. Numerical modeling of sitewide ground-water flow also supported the overall project goals. Water-level monitoring was performed to evaluate ground-water flow directions, to track changes in water levels, and to relate such changes to changes in site disposal practices. Water levels over most of the Hanford Site continued to decline between June 1993 and June 1994. These declines are part of the continued response to the cessation of discharge to U Pond and other disposal facilities. The low permeability in this area which enhanced mounding of waste-water discharge has also slowed the response to the reduction of disposal.

Dresel, P.E.; Thorne, P.D.; Luttrell, S.P. [and others

1995-08-01T23:59:59.000Z

249

Ground potential rise monitor  

SciTech Connect

A device and method for detecting ground potential rise (GPR) comprising positioning a first electrode and a second electrode at a distance from each other into the earth. The voltage of the first electrode and second electrode is attenuated by an attenuation factor creating an attenuated voltage. The true RMS voltage of the attenuated voltage is determined creating an attenuated true RMS voltage. The attenuated true RMS voltage is then multiplied by the attenuation factor creating a calculated true RMS voltage. If the calculated true RMS voltage is greater than a first predetermined voltage threshold, a first alarm is enabled at a local location. If user input is received at a remote location acknowledging the first alarm, a first alarm acknowledgment signal is transmitted. The first alarm acknowledgment signal is then received at which time the first alarm is disabled.

Allen, Zachery W. (Mandan, ND); Zevenbergen, Gary A. (Arvada, CO)

2012-04-03T23:59:59.000Z

250

After-hours power status of office equipment and energy use of miscellaneous plug-load equipment  

Science Conference Proceedings (OSTI)

This research was conducted in support of two branches of the EPA ENERGY STAR program, whose overall goal is to reduce, through voluntary market-based means, the amount of carbon dioxide emitted in the U.S. The primary objective was to collect data for the ENERGY STAR Office Equipment program on the after-hours power state of computers, monitors, printers, copiers, scanners, fax machines, and multi-function devices. We also collected data for the ENERGY STAR Commercial Buildings branch on the types and amounts of miscellaneous plug-load equipment, a significant and growing end use that is not usually accounted for by building energy managers. For most types of miscellaneous equipment, we also estimated typical unit energy consumption in order to estimate total energy consumption of the miscellaneous devices within our sample. This data set is the first of its kind that we know of, and is an important first step in characterizing miscellaneous plug loads in commercial buildings. The main purpose of this study is to supplement and update previous data we collected on the extent to which electronic office equipment is turned off or automatically enters a low power state when not in active use. In addition, it provides data on numbers and types of office equipment, and helps identify trends in office equipment usage patterns. These data improve our estimates of typical unit energy consumption and savings for each equipment type, and enables the ENERGY STAR Office Equipment program to focus future effort on products with the highest energy savings potential. This study expands our previous sample of office buildings in California and Washington DC to include education and health care facilities, and buildings in other states. We report data from sixteen commercial buildings in California, Georgia, and Pennsylvania: four education buildings, two medical buildings, two large offices (> 500 employees each), three medium offices (50-500 employees each), and five small business offices (< 50 employees each). Two buildings are in the San Francisco Bay are a of California, nine (including the five small businesses) are in Pittsburgh, Pennsylvania, and five are in Atlanta, Georgia.

Roberson, Judy A.; Webber, Carrie A.; McWhinney, Marla C.; Brown, Richard E.; Pinckard, Marageret J.; Busch, John F.

2004-05-27T23:59:59.000Z

251

Adaptive Optimization of Central Chiller Plant Equipment Sequencing  

E-Print Network (OSTI)

Control strategies for plant engineering systems are a contemporary research topic of great interest. Their purpose is to provide control that adapts to changes in demand and other operating conditions in order to operate the system at maximum efficiency at all times. The U.S. Department of Energy (DOE) supports research on control models for energy-intensive industrial processes. Likewise, the National Science Foundation (NSF) recognizes the need to develop control algorithms for plant heating, ventilating, and air conditioning (HVAC) systems. In this research paper, a control algorithm was developed to select the optimal sequence of central refrigeration equipment (chillers, cooling towers, pumps) to operate in an industrial plant. The control algorithm adapts the optimal equipment sequence to reflect changes in the plant's cooling load and outside air conditions and it insures that the central refrigeration system operates with the lowest possible energy cost at all times.

Fiorino, D. P.; Priest, J. W.

1987-09-01T23:59:59.000Z

252

Energy Efficiency Standards for Residential and Commercial Equipment...  

NLE Websites -- All DOE Office Websites (Extended Search)

Standards for Residential and Commercial Equipment: Additional Opportunities Title Energy Efficiency Standards for Residential and Commercial Equipment: Additional...

253

SUPPORT STRUCTURE  

DOE Patents (OSTI)

The core support structure for fuel elements of a fast reactor is described. The support structure comprises a nest of tubes of alternately long and short length in longitudinally parallel relationship and arranged in a symmetrical hexagonal lattice. Each tube has a hexagonal section of flat contact faces disposed intermediate its ends and at points wherein tube pairs are engaged in face to face contact. One of each pair of adjacent tubes is slotted to receive the intersecting portion of the other tube of the pair, the intersecting portion bearing against the fuel element contained in the slotted tube for locating the element therein. (AEC)

Tatlock, J.; Glass, J.A.F.

1962-08-14T23:59:59.000Z

254

Life Extension Guidelines for Other Substation Equipment  

Science Conference Proceedings (OSTI)

Utilities are under increasing pressure to maintain service reliability while operating aging transmission substations with tighter, leaner maintenance budgets and fewer experienced personnel. A structured life extension program can help utilities make equipment maintenance, replacement, and refurbishment decisions that ensure safe, reliable, cost-effective operation of transmission substation equipment.BackgroundThe ...

2012-12-12T23:59:59.000Z

255

General Restaurant Equipment: Order (2013-CE-5344)  

Energy.gov (U.S. Department of Energy (DOE))

DOE ordered General Restaurant Equipment Co. to pay a $8,000 civil penalty after finding General Restaurant Equipment had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

256

Life Extension Guidelines for Other Substation Equipment  

Science Conference Proceedings (OSTI)

Utilities are under increasing pressure to maintain service reliability while operating aging transmission substations with tighter, leaner maintenance budgets and fewer experienced personnel. A structured life extension program can help utilities make equipment maintenance, replacement, and refurbishment decisions that ensure safe, reliable, cost-effective operation of transmission substation equipment.BackgroundEPRI’s Life Extension Guidelines for ...

2013-12-20T23:59:59.000Z

257

Life Extension Guidelines for Substation Equipment  

Science Conference Proceedings (OSTI)

Utilities are under increasing pressure to maintain service reliability while operating aging transmission substations with leaner maintenance budgets and fewer experienced personnel. A structured life extension program can help utilities make equipment maintenance, replacement, and refurbishment decisions that ensure safe, reliable, cost-effective operation of transmission substation equipment. EPRI's life extension guidelines for substationsfirst published in 1995 and periodically revisedsupport curre...

2010-12-22T23:59:59.000Z

258

Ground Water Management Regulations (Louisiana) | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ground Water Management Regulations (Louisiana) Ground Water Management Regulations (Louisiana) Eligibility Agricultural Construction Developer Fuel Distributor Industrial...

259

Arch supports  

NLE Websites -- All DOE Office Websites (Extended Search)

Arch supports Arch supports Name: Tu Age: N/A Location: N/A Country: N/A Date: N/A Question: My question is about the foot. Actually, it's not really on the chemistry of the human body. I have flat feet and I need to wear an orthopedic, otherwise know as an arch support in my shoe. What it does is elevate and support the arch of my foot. Here is my scenario question. The orthopedic is very rigid and has a spring constant much higher than the rest of my foot. As a result, at high pressures, my foot will first absorb some of the force. At higher forces and as my foot had absorbed some of the force, the orthopedic begins to play a greater role. It's much stiffer. Thus a greater proportion of force is placed on my arches than on a person's arches who is not flat footed at high forces. Ideally then, an orthopedic would have the same spring constant as a natural arch and/or the foot. Is this the case of the use of an orthopedic?

260

A Plug-In Electric Vehicle Simulator for Electric Vehicles Supply Equipment Evaluation  

Science Conference Proceedings (OSTI)

The Electric Power Research Institute (EPRI) is developing a portable plug-in electric vehicle simulator to support laboratory testing and evaluation of electric vehicle supply equipment. The device implements the signaling required in the Society of Automotive Engineers J1772 Recommended Practice, SAE Electric Vehicle Conductive Charge Coupler, and provides connection of power quality monitoring and simulated load equipment. The complete unit is self contained and battery powered for ease of field use, ...

2010-12-22T23:59:59.000Z

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Definition: Equipment Health Sensor | Open Energy Information  

Open Energy Info (EERE)

Sensor Sensor Jump to: navigation, search Dictionary.png Equipment Health Sensor Monitoring devices that automatically measure and communicate equipment characteristics that are related to the 'health' and maintenance of the equipment. These characteristics can include, but are not limited to temperature, dissolved gas, and loading. These devices can also automatically generate alarm signals if the equipment characteristics reach critical or dangerous levels.[1] Related Terms sustainability References ↑ [www.smartgrid.gov/sites/default/files/pdfs/description_of_assets.pdf SmartGrid.gov 'Description of Assets'] An LikeLike UnlikeLike You like this.Sign Up to see what your friends like. inline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Equipment_Health_Sensor&oldid=502526

262

Registration, Force Protection Equipment Demonstration - May 2009 |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Registration, Force Protection Equipment Demonstration - May 2009 Registration, Force Protection Equipment Demonstration - May 2009 Registration, Force Protection Equipment Demonstration - May 2009 May 2009 Demonstrating commercially availale physical security/force protection soultions around the world The bombing of Khobar Towers in Saudi Arabia on 25 June 1996 revealed the need for continal vigilance and protection againist terrorist forces intent on harming US personnel and interests. The Chairman if the Joint Chiefs of Staff directed the Services to investigate COTS equipments solutions for physical security/force protection needs. The Office of the Under Secretary of Defense for Acquistion, Technology, and Logistics (OUSD {at&l}) tasked the Office of the US Army Product Manager, force Protection Systems (PM-FPS), to coordiante and facilitate a Force Protection Equipment

263

CVD Equipment Corp | Open Energy Information  

Open Energy Info (EERE)

CVD Equipment Corp CVD Equipment Corp Jump to: navigation, search Name CVD Equipment Corp Place Ronkonkoma, New York Zip 11779 Sector Solar Product New York-based maker of chemical vapour deposition process equipment. This equipment is used in the manufacture of solar and semiconductor fabrication. Coordinates 40.81122°, -73.098744° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.81122,"lon":-73.098744,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

264

Definition: Disturbance Monitoring Equipment | Open Energy Information  

Open Energy Info (EERE)

Disturbance Monitoring Equipment Disturbance Monitoring Equipment Jump to: navigation, search Dictionary.png Disturbance Monitoring Equipment Devices capable of monitoring and recording system data pertaining to a Disturbance. Such devices include the following categories of recorders: Sequence of event recorders which record equipment response to the event., Fault recorders, which record actual waveform data replicating the system primary voltages and currents. This may include protective relays., Dynamic Disturbance Recorders (DDRs), which record incidents that portray power system behavior during dynamic events such as low-frequency (0.1 Hz - 3 Hz) oscillations and abnormal frequency or voltage excursions. Phasor Measurement Units and any other equipment that meets the functional requirements of DMEs may qualify as DMEs.[1]

265

Laboratory Equipment Donation Program - About Us  

Office of Scientific and Technical Information (OSTI)

About LEDP About LEDP The Laboratory Equipment Donation Program (LEDP), formerly the Energy-Related Laboratory Equipment (ERLE) Grant Program, was established by the United States Department of Energy (DOE) to grant surplus and available used energy-related laboratory equipment to universities and colleges in the United States for use in energy oriented educational programs. This grant program is sponsored by the Office of Workforce Development for Teachers and Scientists (WDTS). The listing of equipment available through LEDP is updated as new equipment is identified. It is available at no cost for a limited time and is granted on a first-received qualified application basis. Specific items may be recalled for DOE use and become unavailable through the program after the

266

Equipment qualification research program: program plan  

Science Conference Proceedings (OSTI)

The Lawrence Livermore National Laboratory (LLNL) under the sponsorship of the US Nuclear Regulatory Commission (NRC) has developed this program plan for research in equipment qualification (EQA). In this report the research program which will be executed in accordance with this plan will be referred to as the Equipment Qualification Research Program (EQRP). Covered are electrical and mechanical equipment under the conditions described in the OBJECTIVE section of this report. The EQRP has two phases; Phase I is primarily to produce early results and to develop information for Phase II. Phase I will last 18 months and consists of six projects. The first project is program management. The second project is responsible for in-depth evaluation and review of EQ issues and EQ processes. The third project is responsible for detailed planning to initiate Phase II. The remaining three projects address specific equipment; i.e., valves, electrical equipment, and a pump.

Dong, R.G.; Smith, P.D.

1982-06-08T23:59:59.000Z

267

Office Buildings - End-Use Equipment  

U.S. Energy Information Administration (EIA) Indexed Site

End-Use Equipment End-Use Equipment The types of space heating equipment used in office buildings were similar to those of the commercial buildings sector as a whole (Table 8 and Figure 5). Furnaces were most used followed by packaged heating systems. Individual space heaters were third-most used but were primarily used to supplement the building's main heating system. Boilers and district heat systems were more often used in larger buildings. Table 8. Types of Heating Equipment Used in Office Buildings, 2003 Number of Buildings (thousand) Total Floorspace (million square feet) All Buildings* All Office Buildings All Buildings* All Office Buildings All Buildings 4,645 824 64,783 12,208 All Buildings with Space Heating 3,982 802 60,028 11,929 Heating Equipment (more than one may apply)

268

Definition: Equipment Condition Monitor | Open Energy Information  

Open Energy Info (EERE)

Condition Monitor Condition Monitor Jump to: navigation, search Dictionary.png Equipment Condition Monitor A monitoring device that automatically measures and communicates equipment characteristics that are related to the "health" and maintenance of the equipment. These characteristics can include, but are not limited to temperature, dissolved gas, and loading. These devices can automatically generate alarm signals if conditions exceed preset thresholds.[1] Related Terms sustainability References ↑ https://www.smartgrid.gov/category/technology/equipment_condition_monitor [[C LikeLike UnlikeLike You like this.Sign Up to see what your friends like. ategory: Smart Grid Definitions|Template:BASEPAGENAME]] Retrieved from "http://en.openei.org/w/index.php?title=Definition:Equipment_Condition_Monitor&oldid=502601"

269

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

General Service Fluorescent Lamps General Service Fluorescent Lamps Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of general service fluorescent lamps (GSFLs) since 1994. GSFLs are fluorescent tubes with pins at one or both ends for installation. These lamps are generally installed in ceilings. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates DOE published a notice of public meeting and availability of preliminary technical support document regarding energy conservation standards for GSFLs. 78 FR 13563 (February 28, 2013). DOE later published a notice of correction. 78 FR 14467 (March 6, 2013). For more information, please see the rulemaking webpage.

270

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Televisions Test Procedure Televisions Test Procedure Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is establishing a test procedure for televisions. This rulemaking is governed by the Energy Policy and Conservation Act (EPCA). Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a final rule regarding test procedures for televisions. 78 FR 63823 (October 25, 2013). Public Meeting Information No public meeting is scheduled at this time. Submitting Public Comments The comment period is closed. Milestones and Documents The televisions test procedures rulemaking docket number EERE-2010-BT-TP-0026 contains all notices, public comments, public meeting transcripts, and supporting documents. For the latest information on the planned timing of future DOE regulatory milestones, see the current Office of Management and Budget Unified Agenda of Regulatory and Deregulatory Actions. All planned dates are preliminary and subject to change.

271

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

High-Intensity Discharge Lamps Energy Conservation Standard High-Intensity Discharge Lamps Energy Conservation Standard Sign up for e-mail updates on regulations for this and other products High-intensity discharge (HID) lamps include mercury vapor (MV), metal halide (MH), and high-pressure sodium (HPS) lamps. The Department of Energy (DOE) is considering establishing energy conservation standards for certain HID lamps. This rulemaking is mandated by the Energy Policy and Conservation Act (EPCA). (42 USC 6311-6317) Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a notice of public meeting and availability of interim technical support document regarding energy conservation standards for high-intensity discharge lamps. 78 FR 13566 (February 28, 2013).

272

Building Equipment Technologies | Clean Energy | ORNL  

NLE Websites -- All DOE Office Websites (Extended Search)

rooftop units Appliances Water heaters Supermarket refrigeration systems Ground-source space conditioning and water heating systems Multi-zone heating, ventilation, and air...

273

HVAC Equipment Design Options for Near-Zero-Energy Homes - Scoping Assessment of Radiant Panel Distribution System Options  

Science Conference Proceedings (OSTI)

Although the energy efficiency of heating, ventilating, and air-conditioning (HVAC) equipment has increased substantially in recent years, new approaches are needed to continue this trend. Conventional unitary equipment and system designs have matured to a point where cost-effective, dramatic efficiency improvements that meet near-zero-energy housing (NZEH) goals require a radical rethinking of opportunities to improve system performance. The large reductions in HVAC energy consumption necessary to support the NZEH goals require a systems-oriented analysis approach that characterizes each element of energy consumption, identifies alternatives, and determines the most cost-effective combination of options. In particular, HVAC equipment must be developed that addresses the range of special needs of NZEH applications in the areas of reduced HVAC and water heating energy use, humidity control, ventilation, uniform comfort, and ease of zoning. In FY05, ORNL conducted a scoping-level assessment of HVAC system options for NZEH homes (Baxter 2005). That report examined some twenty HVAC and water heating (HVAC/WH) systems in two 1800 ft2 houses--one constructed to Building America Research Benchmark standards and one a prototype NZEH. Both centrally ducted and two-zone systems were examined in that study. The highest scoring options using the ranking criteria described in that report were air-source and ground-source integrated heat pumps (IHP), and these were selected by DOE for further development. Among the feedback received to the FY05 report was a comment that systems using radiant panel (floor or ceiling) distribution options were not included among the system examined. This present report describes an assessment of a few such radiant panel systems under the same analysis and ranking criteria used in Baxter (2005). The rankings of the radiant system options reported herein are based on scoring by the team of building equipment researchers at ORNL. It is DOE's prerogative to revisit the criteria and obtain scoring from additional perspectives as part of its decision making process. If the criteria change, the ORNL team will be happy to re-score.

Baxter, Van David [ORNL

2007-06-01T23:59:59.000Z

274

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Residential Central Air Conditioners and Heat Pumps Test Procedure Residential Central Air Conditioners and Heat Pumps Test Procedure Sign up for e-mail updates on regulations for this and other products DOE is conducting a rulemaking to revise the test procedures for residential central air conditioners and heat pumps. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a supplemental notice of proposed rulemaking regarding test procedures for residential central air conditioners and heat pumps. 76 FR 65616 (Oct. 24, 2011). Public Meeting Information No public meeting is scheduled at this time. Submitting Public Comments The comment period is closed. Milestones and Documents The residential central air conditioners and heat pumps test procedure rulemaking docket EERE-2009-BT-TP-0004 contains all notices, public comments, public meeting transcripts, and supporting documents. For the latest information on the planned timing of future DOE regulatory milestones, see the current Office of Management and Budget Unified Agenda of Regulatory and Deregulatory Actions. All planned dates are preliminary and subject to change.

275

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

Test Procedure Test Procedure Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is considering developing test procedures for residential furnace fans. This rulemaking is mandated by the Energy Policy and Conservation Act (EPCA). Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a final rule regarding test procedures for residential furnace fans. 79 FR 499 (January 3, 2014). Public Meeting Information There is no public meeting scheduled at this time. Submitting Public Comments The comment period is closed. Milestones and Documents The residential furnace fans test procedure rulemaking docket EERE-2010-BT-TP-0010 contains all notices, public comments, public meeting transcripts, and supporting documents. For the latest information on the planned timing of future DOE regulatory milestones, see the current Office of Management and Budget Unified Agenda of Regulatory and Deregulatory Actions. All planned dates are preliminary and subject to change.

276

Energy efficiency standards for residential and commercial equipment: Additional  

NLE Websites -- All DOE Office Websites (Extended Search)

207 207 Energy Efficiency Standards for Residential and Commercial Equipment: Additional Opportunities Greg Rosenquist, Michael McNeil, Maithili Iyer, Steve Meyers, and Jim McMahon Environmental Energy Technologies Division Lawrence Berkeley National Laboratory University of California Berkeley, CA 94720 September 2004 This work was supported by the National Commission on Energy Policy through the U.S. Department of Energy under Contract No. DE-AC03-76SF00098. Table of Contents 1. Introduction........................................................................1 2. Products Considered..............................................................2 3. Technology Cost-Efficiency Analysis...........................................3

277

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 2, Fluorescent lamp ballasts, television sets, room air conditioners, and kitchen ranges and ovens  

SciTech Connect

This document is divided into ``volumes`` B through E, dealing with individual classes of consumer products. Chapters in each present engineering analysis, base case forecasts, projected national impacts of standards, life-cycle costs and payback periods, impacts on manufacturers, impacts of standards on electric utilities, and environmental effects. Supporting appendices are included.

Not Available

1993-11-01T23:59:59.000Z

278

Appliances and Commercial Equipment Standards: Guidance  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Office Office HOME ABOUT ENERGY EFFICIENT TECHNOLOGIES RESIDENTIAL BUILDINGS COMMERCIAL BUILDINGS APPLIANCE & EQUIPMENT STANDARDS BUILDING ENERGY CODES EERE » Building Technologies Office » Appliances & Equipment Standards About Standards & Test Procedures Implementation, Certification & Enforcement Rulemakings & Notices Further Guidance ENERGY STAR® Guidance and Frequently Asked Questions This webpage is designed to provide guidance and answer Frequently Asked Questions (FAQs) on the U.S. Department of Energy's appliance standards program. Guidance types span all covered products and covered equipment and cover such topics as: definitions, scope of coverage, conservation standards, test procedures, certification, Compliance and Certification Management System (CCMS), and enforcement. This website offers users an

279

Water-Using Equipment: Commercial and Industrial  

Science Conference Proceedings (OSTI)

Water is an important aspect of many facets in energy engineering. While the previous article detailed domestic related water-using equipment such as toilets and showerheads, this article focuses on various types of water-using equipment in commercial and industrial facilities, including commercial dishwashers and laundry, single-pass cooling equipment, boilers and steam generators, cooling towers, and landscape irrigation. Opportunities for water and energy conservation are explained, including both technology retrofits and operation and maintenance changes. Water management planning and leak detection are also included as they are essential to a successful water management program.

Solana, Amy E.; McMordie-Stoughton, Katherine L.

2006-01-24T23:59:59.000Z

280

New surface equipment for underbalanced drilling  

Science Conference Proceedings (OSTI)

Perhaps the single most exciting development in the area of new drilling technology in this decade is underbalanced drilling (UBD). This category includes both jointed pipe and coiled tubing applications. Each has advantages and disadvantages in UBD operations. Regardless of the method selected for a particular UBD application, equipment similarities exist. The surface control and production equipment must be correctly sized and designed for the overall total UBD engineering solution. This article describes the various types, applications and purposes of special surface equipment needed in underbalanced operations. This is the second in a series of articles on UBD technology and its rapid development is this field.

Cuthbertson, R.L.; Vozniak, J.; Kinder, J.

1997-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Balance of Substation Equipment Condition Assessment and Life-Extension Techniques  

Science Conference Proceedings (OSTI)

The work reported in this technical update is part of an ongoing Electric Power Research Institute (EPRI) effort to improve the balance of station equipment life management; this report presents results of investigations of issues, typical problems, and utility maintenance needs concerning substation high-voltage disconnect and grounding switches. This project phase included a needs assessment and research roadmap development to identify and address maintenance and other life cycle issues for manual and ...

2011-12-13T23:59:59.000Z

282

EPA Final Ground Water Rule  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Office of Nuclear Safety and Environment Office of Nuclear Safety and Environment Nuclear Safety and Environment Information Brief HS-20-IB-2007-02 (March 2007) EPA Final Ground Water Rule Safe Drinking Water Act: National Primary Drinking Water Regulations Ground Water Rule - 40 CFR Parts 9, 141 and 142 Final Rule: 71 FR 65574 Effective Date: January 8, 2007 1 RULE SYNOPSIS On November 8, 2006, the U.S. Environmental Protection Agency (EPA) published a final Ground Water Rule (GWR) to promote increased protection against microbial pathogens that may be present in public water systems (PWSs) that use ground water sources for their supply (these systems are known as ground water systems). This Rule establishes a risk-targeted approach

283

Transient performance of substation structures and associated grounding systems  

Science Conference Proceedings (OSTI)

When lightning strikes an electric substation, large currents generated by the stroke flow in the above ground structures and grounding system and dissipate in the soil. The electromagnetic fields generated by such high currents may cause damage to equipment and may be dangerous to personnel working nearby. In this paper, the frequency and time domain performance of a substation subjected to a lightning strike is described and discussed. The computed scalar potentials, electric fields, and magnetic fields are presented graphically as a function of spatial coordinates, as a function of time and as a function of both. Two cases are considered. The first case examines the substation grounding system only, while the second case includes an above-ground structure as well. It is believed that the results of the second case have not been published before. A double exponential lightning surge current is injected at one corner of the substation. The response of the grounding system to the frequency domain electromagnetic spectrum of this signal is computed by a frequency domain electromagnetic field analysis software package. The temporal and spatial distributions of the electromagnetic fields inside and near the substation are obtained by an inverse Fourier transformation of all these responses. The presence of a soil with an arbitrary resistivity and permittivity is accurately taken into account. The analysis sheds some new light on the understanding of the effects which take place at the higher frequencies.

Dawalibi, F.P.; Xiong, W.; Ma, J. [Safe Engineering Services and Technologies Ltd., Montreal, Quebec (Canada)

1995-05-01T23:59:59.000Z

284

Instrumentation and Equipment for Three Independent Research Labs  

SciTech Connect

Completed in 2011, Albright's new Science Center includes three independent student and faculty research labs in Biology, Chemistry/Biochemistry, and Physics (separate from teaching labs). Providing independent research facilities, they eliminate disruptions in classrooms and teaching labs, encourage and accommodate increased student interest, and stimulate advanced research. The DOE grant of $369,943 enabled Albright to equip these advanced labs for 21st century science research, with much instrumentation shared among departments. The specialty labs will enable Albright to expand its student-faculty research program to meet growing interest, help attract superior science students, maximize faculty expertise, and continue exceeding its already high rates of acceptance for students applying for postgraduate education or pharmaceutical research positions. Biology instrumentation/equipment supports coursework and independent and collaborative research by students and faculty. The digital shaker, CO{sub 2} and water bath incubators (for controlled cell growth), balance, and micropipettes support cellular biology research in the advanced cell biology course and student-faculty research into heavy metal induction of heat shock proteins in cultured mammalian cells and the development of PCR markers from different populations of the native tree, Franklinia. The gravity convection oven and lyophilizer support research into physical and chemical analysis of floodplain sediments used in assessment of riparian restoration efforts. The Bio-Rad thermocycler permits fast and accurate DNA amplification as part of research into genetic diversity in small mammal populations and how those populations are affected by land-use practices and environmental management. The Millipore water deionizing system and glassware washer provide general support of the independent research lab and ensure quality control of coursework and interdisciplinary research at the intersection of biology, chemistry, and toxicology. Grant purchases support faculty and students working in the areas of plant cellular biology, landscape ecology and wildlife management, wetland restoration, and ecotoxicology of aquatic invertebrates. Chemistry/BioChemistry instrumentation supports a wide range of research and teaching needs. The Dell quad core Xeon processors and Gaussian 09 support computational research efforts of two of our faculty. The computational work of one of these groups is part of close collaboration with one organic chemist and provides support info for the synthetic work of this professor and his students. Computational chemistry studies were also introduced into the physical chemistry laboratory course for junior chemistry concentrators. The AKTA plus system and superdex columns, Thermoscientific Sorvall RC-6 plus superspeed centrifuge, Nanodrop spectrometer, Eppendorf microfuge, Homogenizer and Pipetman pipetters were incorporated into a research project involving purification and characterization of a construct of beta 2-microglobulin by one of our biochemists. The vacuum system (glove box, stand, and pump) makes a significant contribution to the research of our inorganic chemist, the newest department member, working on research projects with four students. The glove box provides the means to carry out their synthetic work in an oxygenless atmosphere. Supporting basic research pursued by faculty and students, the remaining items (refrigerator/freezer units for flammable storage, freezer, refrigerated water bath, rotary evaporator system, vacuum oven, analytical and top-loading balances) were distributed between our biochemistry and chemistry research labs. The Nanodrop spectrometer, Sorvall centrifuge, and rotary evaporator system are used in several junior/senior lab courses in both biochemistry and chemistry. To date, 14 undergraduate research students have been involved in projects using the new instrumentation and equipment provided by this grant. Physics equipment acquired is radically transforming Albright research and teaching capabilities. The tw

Darlene Roth

2012-03-29T23:59:59.000Z

285

Definition: Equipment Rating | Open Energy Information  

Open Energy Info (EERE)

Rating Rating Jump to: navigation, search Dictionary.png Equipment Rating The maximum and minimum voltage, current, frequency, real and reactive power flows on individual equipment under steady state, short-circuit and transient conditions, as permitted or assigned by the equipment owner.[1] Also Known As Standard current ratings Related Terms reactive power, smart grid References ↑ Glossary of Terms Used in Reliability Standards An i LikeLike UnlikeLike You like this.Sign Up to see what your friends like. nline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Equipment_Rating&oldid=502535" Categories: Definitions ISGAN Definitions What links here Related changes Special pages Printable version Permanent link Browse properties

286

Piedmont Natural Gas - Residential Equipment Efficiency Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Piedmont Natural Gas - Residential Equipment Efficiency Program Piedmont Natural Gas - Residential Equipment Efficiency Program Piedmont Natural Gas - Residential Equipment Efficiency Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Appliances & Electronics Water Heating Maximum Rebate 2 rebates per household Program Info State North Carolina Program Type Utility Rebate Program Rebate Amount High-Efficiency Furnace: $175 Tankless Water Heater: $150 Tank Water Heater: $50 Provider Gas Technology and Energy Services Piedmont Natural Gas offers rebates on high-efficiency natural gas tankless water heaters, tank water heaters and furnaces. Customers on the 101-Residential Service rate are eligible for these rebates. Rebates are only provided for qualifying natural gas equipment that is installed to

287

Laboratory Equipment Donation Program - Home Page  

NLE Websites -- All DOE Office Websites (Extended Search)

U.S. Department of Energy U.S. Department of Energy Laboratory Equipment Donation Program Home About LEDP FAQ Application Site Index Contact Us Administrative Login SEARCH: Go! view equipment list LEDP News Latest Equipment Added as of January 08, 2014: 1. DATA HANDLING SYSTEM 89514133530195 2. METER, VOLT 89514133530179 3. RECORDER, STRIP 89514133530184 4. RECORDER, STRIP 89514133530185 5. SCINTILLATOR STRIPS, 1.9 CM X 1.5 CM X 96 CM 89514133530188 Quick Links What type of equipment is available? Who is eligible to apply? How long will it take to find out if my application has been approved? Who is responsible for arranging and paying for shipping? RSS Get Widgets Bookmark and Share Get the tools you need to inspire innovation and creativity The United States Department of Energy (DOE), in accordance with its

288

Energy Sub-Metering Equipment and Applications  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Sub-Metering Equipment and Applications Energy Sub-Metering Equipment and Applications Speaker(s): Sim Gurewitz Date: July 24, 2008 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Paul Mathew This talk will address the following topics:Submetering basics: What is it? How does a submeter work?How to obtain a finer level of energy information within the buildingApplications: Who submeters and why?LEED NC/EB/CS and submetering / Energy & Atmosphere pointsSubmetering equipment: gas, electric, water, steam, CW Btu and HHW BtuHow to install equipment without scheduling an outageLoad Control option for automated load shedding and peak shavingWireless submeters and communication options / integration to EMS-BMCSAutomatic remote meter reading and cost allocation softwarePutting it all together into a metering SYSTEM: read from anywhere, IP

289

HVAC Equipment Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Equipment Rebate Program HVAC Equipment Rebate Program HVAC Equipment Rebate Program < Back Eligibility Agricultural Commercial Industrial Installer/Contractor Institutional Multi-Family Residential Nonprofit Schools Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Heat Pumps Maximum Rebate Rebates of greater than $5,000 require pre-approval Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Varies depending on technology and efficiency Provider Efficiency Vermont NOTE: Rebate reservations are required for all boiler and furnace projects. Efficiency Vermont offers rebates for commercial installations of high-efficiency HVAC equipment and controls. For businesses and purchases

290

Consider Steam Turbine Drives for Rotating Equipment  

SciTech Connect

This revised ITP tip sheet on steam turbine drives for rotating equipment provides how-to advice for improving the system using low-cost, proven practices and technologies.

2006-01-01T23:59:59.000Z

291

NETL: Carbon Absorber Retrofit Equipment (CARE)  

NLE Websites -- All DOE Office Websites (Extended Search)

Emissions Control Carbon Absorber Retrofit Equipment (CARE) Project No.: DE-FE0007528 Spray Jet Array for Neustream-C Nozzle Technology Spray Jet Array for Neustream-C Nozzle...

292

Definition: Reduced Equipment Failures | Open Energy Information  

Open Energy Info (EERE)

limits based on real-time equipment or environmental factors.1 Related Terms sustainability References SmartGrid.gov 'Description of Benefits' An LikeLike UnlikeLike You...

293

Biomass Equipment & Materials Compensating Tax Deduction  

Energy.gov (U.S. Department of Energy (DOE))

In 2005 New Mexico adopted a policy to allow businesses to deduct the value of biomass equipment and biomass materials used for the processing of biopower, biofuels or biobased products in...

294

Enhanced Substation Equipment Industry-Wide Database  

Science Conference Proceedings (OSTI)

The Electric Power Research Institute (EPRI) Industrywide Equipment Performance Database (IDB) for transformers is a collaborative effort to pool appropriate transformer operating and failure data in order to assemble a statistically valid population of many types of transformers.

2008-12-18T23:59:59.000Z

295

Hot conditioning equipment conceptual design report  

SciTech Connect

This report documents the conceptual design of the Hot Conditioning System Equipment. The Hot conditioning System will consist of two separate designs: the Hot Conditioning System Equipment; and the Hot Conditioning System Annex. The Hot Conditioning System Equipment Design includes the equipment such as ovens, vacuum pumps, inert gas delivery systems, etc.necessary to condition spent nuclear fuel currently in storage in the K Basins of the Hanford Site. The Hot Conditioning System Annex consists of the facility of house the Hot Conditioning System. The Hot Conditioning System will be housed in an annex to the Canister Storage Building. The Hot Conditioning System will consist of pits in the floor which contain ovens in which the spent nuclear will be conditioned prior to interim storage.

Bradshaw, F.W., Westinghouse Hanford

1996-08-06T23:59:59.000Z

296

Cruising Equipment Company CECO | Open Energy Information  

Open Energy Info (EERE)

Cruising Equipment Company CECO Cruising Equipment Company CECO Jump to: navigation, search Name Cruising Equipment Company (CECO) Place Seattle, Washington Zip 98107 Product Maker of pollution control equipment - bought by Xantrex in 2000. Coordinates 47.60356°, -122.329439° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":47.60356,"lon":-122.329439,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

297

Ground Breaking of Blythe Solar Power Project | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ground Breaking of Blythe Solar Power Project Ground Breaking of Blythe Solar Power Project Ground Breaking of Blythe Solar Power Project June 20, 2011 - 2:16pm Addthis Secretary Chu Secretary Chu Former Secretary of Energy What will the project do? Blythe Solar Power Project will generate 1,000 megawatts of solar power, enough to power more than 300,000 single-family homes a year. Back in April, I had the pleasure of announcing that the Department of Energy had extended our largest conditional loan guarantee for a solar project - $2.1 billion to support a concentrating solar thermal power plant near Blythe, California. Last Friday, the Blythe Solar Power Project broke ground, beginning construction of a project that upon completion will generate 1,000 megawatts of solar power, enough to power more than 300,000

298

Integrating Equipment Health Information Into Grid Operations  

Science Conference Proceedings (OSTI)

In recent years, grid operators have expressed keen interest in having equipment health information available in real time. The health status of critical power system equipment can help operators assess situations, identify associated risks, and develop mitigation strategies/solutions in a time frame commensurate with the risk level. Health status information can also help operators recognize potential failures and take proactive actions, such as unloading a transformer or breaker that has shown signs of...

2011-12-21T23:59:59.000Z

299

Specifying and Testing Superconducting Power Equipment  

Science Conference Proceedings (OSTI)

EPRI held a workshop on September 21, 2007 in Hauppauge, New York to discuss what is needed to develop standards and specifications for testing superconducting power equipment. Stakeholders, including developers, equipment manufacturers, and electric utilities, participated in the discussions, which were arranged in a semi-formal setting to promote open dialogue. The U.S. Department of Energy provided assistance with meeting facilitation and recording.

2008-07-22T23:59:59.000Z

300

An Approach to Evaluating Equipment Efficiency Policies  

E-Print Network (OSTI)

The National Energy Conservation Policy Act of 1978 authorized studies of several types of industrial equipment to evaluate the technical and economic feasibility of labeling rules and minimum energy efficiency standards. An approach to the evaluation of these and related policy options is under development. The approach includes equipment classification and characterization, market characterization, and the subsequent evaluation of effectiveness and costs of the policy options. Technical, economic, and marketing data obtained with the cooperation of industrial groups, such of policy impacts.

Newsom, D. E.; Evans, A. R.

1980-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Seaport Land-Side Equipment Electrification Opportunities  

Science Conference Proceedings (OSTI)

The air quality problems associated at the Ports, have become a widely discussed issue facing cargo handling in recent years. While growth is necessary for economic health, the pollution emitted is growing as well. This study gives an overview of the many aspects of the port that can be considered for electrification. The emphasis of the work is a complete review of the land side equipment. Primary equipment includes: terminal tractors, forklifts, top loaders, empty container handlers, non-road vehicles,...

2006-01-24T23:59:59.000Z

302

Substation Equipment Asset Management: Utility Experience Sharing  

Science Conference Proceedings (OSTI)

Utilities have been maintaining substation equipment reliably since the industry’s inception, but now many are facing increased challenges to reduce operating and maintenance costs without adversely affecting service levels. In this setting, utilities may benefit from knowing which programs and techniques their peers have implemented. To that end, the Electric Power Research Institute (EPRI) conducted a series of industry surveys assessing key substation equipment maintenance practices. As ...

2013-12-18T23:59:59.000Z

303

Contracting for Support Services | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Guidance Guidance » Contracting for Support Services Contracting for Support Services What you need to know as a Federal Employee The Department of Energy, like most Federal agencies, spends a significant amount of its contracting budget on support services. While these contracts fulfill continuing and essential needs of the Department, this type of contracting arrangement can present unique situations that require special diligence on the part of Federal employees to ensure that applicable statutes, regulations, and management practices are followed. Contracts for support services cover a wide range of areas and may include: - Maintenance, overhaul, repair and servicing of equipment. - Housekeeping services. - Advisory and assistance services. - Transportation services.

304

List of Agricultural Equipment Incentives | Open Energy Information  

Open Energy Info (EERE)

Agricultural Equipment Incentives Agricultural Equipment Incentives Jump to: navigation, search The following contains the list of 90 Agricultural Equipment Incentives. CSV (rows 1 - 90) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Agricultural Energy Efficiency Program (New York) State Rebate Program New York Agricultural Agricultural Equipment Boilers Chillers Custom/Others pending approval Dishwasher Furnaces Heat pumps Heat recovery Lighting Lighting Controls/Sensors Motor VFDs Motors Water Heaters Commercial Cooking Equipment Commercial Refrigeration Equipment Food Service Equipment Yes Agricultural Lighting and Equipment Rebate Program (Vermont) State Rebate Program Vermont Agricultural Agricultural Equipment Custom/Others pending approval Lighting

305

CRAD, Nuclear Facility Construction - Mechanical Equipment - June 26, 2012  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Nuclear Facility Construction - Mechanical Equipment - June Nuclear Facility Construction - Mechanical Equipment - June 26, 2012 CRAD, Nuclear Facility Construction - Mechanical Equipment - June 26, 2012 June 26, 2012 Nuclear Facility Construction - Mechanical Equipment Installation, (HSS CRAD 45-53, Rev. 0) The purpose of this criteria review and approach, this CRAD includes mechanical equipment installation, including connections of the equipment to installed piping systems, and attachments of the equipment to structures (concrete, structural steel, or embed plates). Mechanical equipment includes items such as pumps and motors, valves, tanks, glove boxes, heat exchangers, ion exchangers, service air system, fire pumps and tanks, and heating, ventilation, and air condition (HVAC) equipment such as fans, scrubbers and filters.

306

Alternative Fuels Data Center: Pollution Control Equipment Exemption  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Pollution Control Pollution Control Equipment Exemption to someone by E-mail Share Alternative Fuels Data Center: Pollution Control Equipment Exemption on Facebook Tweet about Alternative Fuels Data Center: Pollution Control Equipment Exemption on Twitter Bookmark Alternative Fuels Data Center: Pollution Control Equipment Exemption on Google Bookmark Alternative Fuels Data Center: Pollution Control Equipment Exemption on Delicious Rank Alternative Fuels Data Center: Pollution Control Equipment Exemption on Digg Find More places to share Alternative Fuels Data Center: Pollution Control Equipment Exemption on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Pollution Control Equipment Exemption Dedicated original equipment manufacturer natural gas vehicles and

307

Applying Grounded Theory to Understand Software Process Improvement Implementation  

Science Conference Proceedings (OSTI)

Recent studies show that many organizations struggle to implement Software Process Improvement (SPI) based on process models and standards mainly because of incapacity to overcome critical barriers, such as lack of motivation and higher management support. ... Keywords: Grounded Theory, Software Process Improvement (SPI)

Mariano Angel Montoni; Ana Regina Rocha

2010-09-01T23:59:59.000Z

308

Object Recognition by Sequential Figure-Ground Ranking  

Science Conference Proceedings (OSTI)

We present an approach to visual object-class segmentation and recognition based on a pipeline that combines multiple figure-ground hypotheses with large object spatial support, generated by bottom-up computational processes that do not exploit knowledge ... Keywords: Learning and ranking, Object recognition, Semantic segmentation

Joăo Carreira; Fuxin Li; Cristian Sminchisescu

2012-07-01T23:59:59.000Z

309

Electronic Technology Support of Programmatic Divisions  

NLE Websites -- All DOE Office Websites (Extended Search)

Electronic Technology Support of Programmatic Divisions Electronic Technology Support of Programmatic Divisions Speaker(s): Brad Bingham Date: March 13, 2003 - 12:00pm Location: 90-3148 The Electronics Technology Group within the Engineering Division possesses a number capabilities and skilled staff that can provide support to projects within the programmatic Divisions. Different areas of expertise include electronic fabrication, prototyping, repair and maintenance of existing equipment and instrument calibration. Electronic fabrication capabilities are from the printed circuit board level to electronic packaging and equipment chassis builds to the large multi-rack control system level. The Electronics Technology Group also has a personnel matrix program to support projects with full time, part time or limited time

310

International Conference on Ground Control in Mining SDPS for Windows: An Integrated Approach to Ground Deformation Prediction  

E-Print Network (OSTI)

and monitoring of coal mining operations. As a result, the development of rigorous and well-accepted ground of support, extracted height, rate of advance, etc. · Site Factors: Refer to the geotechnical conditions of detailed subsidence monitoring for an unrelated study. Data from these sites was chosen for SDPS

311

Target System and Support Facility 3.1 Introduction  

E-Print Network (OSTI)

of the facility, a maintenance cell at the ground floor elevation for handling magnet components, a hot cell at the tunnel level for mercury target system components, and various remote-handling equipment used-Z targets, such as Inconel, or mercury. It would also be expected to get too hot with a 4 MW beam, which we

McDonald, Kirk

312

Remote handling equipment at the hanford waste treatment plant  

Science Conference Proceedings (OSTI)

Cold war plutonium production led to extensive amounts of radioactive waste stored in tanks at the Department of Energy's Hanford Waste Treatment Plant. The storage tanks could potentially leak into the ground water and into the Columbia River. The solution for this risk of the leaking waste is vitrification. Vitrification is a process of mixing molten glass with radioactive waste to form a stable condition for storage. The Department of Energy has contracted Bechtel National, Inc. to build facilities at the Hanford site to process the waste. The waste will be separated into high and low level waste. Four major systems will process the waste, two pretreatment and two high level. Due to the high radiation levels, high integrity custom cranes have been designed to remotely maintain the hot cells. Several critical design parameters were implemented into the remote machinery design, including radiation limitations, remote operations, Important to Safety features, overall equipment effectiveness, minimum wall approaches, seismic constraints, and recovery requirements. Several key pieces of equipment were designed to meet these design requirements - high integrity crane bridges, trolleys, main hoists, mast hoists, slewing hoists, a monorail hoist, and telescoping mast deployed tele-robotic manipulator arms. There were unique and challenging design features and equipment needed to provide the remotely operated high integrity crane/manipulator systems for the Hanford Waste Treatment Plant. The cranes consist of a double girder bridge with various main hoist capacities ranging from one to thirty ton and are used for performing routine maintenance. A telescoping mast mounted tele-robotic manipulator arm with a one-ton hook is deployed from the trolley to perform miscellaneous operations in-cell. A dual two-ton slewing jib hoist is mounted to the bottom of the trolley and rotates 360 degrees around the mast allowing the closest hook wall approaches. Each of the two hoists on this slewer is mounted 180 degrees opposite each other. Another system utilizes a single one-ton slewing jib hoist that can extend and retract as well as rotate 270 degrees around the mast. Yet, another system utilizes an under-hung monorail trolley with one-ton hoist capacity mounted to the bottom of the bridge girder. The main, slewer and monorail hoists each have power-rotating hooks for installing and removing equipment in the hot cell. (authors)

Bardal, M.A. [PaR Systems, Inc., Shoreview, MN, (United States); Roach, J.D. [Bechtel National, Inc., Richland, WA (United States)

2007-07-01T23:59:59.000Z

313

Solar Resources Measurements in Houston, TX -- Equipment Only: Cooperative Research and Development Final Report, CRADA Number CRD-06-204  

SciTech Connect

Loaning Texas Southern University equipment in order to perform site-specific, long-term, continuous, and high-resolution measurements of solar irradiance is important for developing renewable resource data. These data are used for several research and development activities consistent with the NREL mission: (1) establish a national 30-year climatological database of measured solar irradiances; (2) provide high quality ground-truth data for satellite remote sensing validation; (3) support development of radiative transfer models for estimating solar irradiance from available meteorological observations; (4) provide solar resource information needed for technology deployment and operations. Data acquired under this agreement will be available to the public through NREL's Measurement & Instrumentation Data Center - MIDC (http://www.nrel.gov/midc) Or the Renewable Resource Data Center - RReDC (http://rredc.nrel.gov). The MIDC offers a variety of standard data display, access, and analysis tools designed to address the needs of a wide user audience (e.g., industry, academia, and government interests).

Stoffel, T.

2012-09-01T23:59:59.000Z

314

Comment submitted by Hobart/ITW Food Equipment Group regarding the Energy Star Verification Testing Program  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

May 9, 2011 May 9, 2011 DOE Verification Program May 9, 2011 Ashley Armstrong US Department of Energy Reference: DOE Verification Testing in Support of ENERGY STAR Subject: Comments from Hobart, Div. ITW Food Equipment Group Dear Ms. Armstrong, Hobart/ITW Food Equipment Group has been working diligently with the US EPA through NAFEM to ensure that the ENERGY STAR enhancements are fair to Food Service Equipment manufacturers. One of the mainstays has always been that Commercial Food Service equipment should not be required to be verification tested by a third party laboratory. We firmly believe that the proven method of periodic inspections by third-party certification bodies is more than adequate for verifying compliance with energy consumption standards. To that end, we

315

EA-1137: Nonnuclear Consolidation Weapons Production Support Project for  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

137: Nonnuclear Consolidation Weapons Production Support 137: Nonnuclear Consolidation Weapons Production Support Project for the Kansas City Plant, Kansas City, Missouri EA-1137: Nonnuclear Consolidation Weapons Production Support Project for the Kansas City Plant, Kansas City, Missouri SUMMARY This EA evaluates the environmental impacts of the proposal to renovate an existing building at the U.S. Department of Energy Kansas City Plant to accommodate equipment, security and environmental controls, and building restoration upon project completion, including disposal of equipment and wastes. PUBLIC COMMENT OPPORTUNITIES None available at this time. DOCUMENTS AVAILABLE FOR DOWNLOAD December 21, 1995 EA-1137: Finding of No Significant Impact Nonnuclear Consolidation Weapons Production Support Project for the Kansas

316

RECORD OF CATEGORICAL EXCLUSION DETERMINATION Ault Substation Expansion and Equipment Additions, Weld County, CO  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ault Substation Expansion and Equipment Additions, Weld County, CO Ault Substation Expansion and Equipment Additions, Weld County, CO A. Proposed Action: Western proposes to expand the existing Ault SUbstation and add electrical equipment. The expansion would be within the existing fee-owned land. B. Number and Title of Categorical Excluison Being Applied . B4.11: Construction of electric power substations (including switching stations and support facilities) with power deliver at 230-kV or below, or modification (other than voltage increases) of existing sutstations and support facilities .. .. C. Regulatory Requirements in 10 CFR 1021.410(b): (Refer to full text in regulation ). (1) The proposed action fits within a class of actions that is listed in Appendix A or B to Subpart D. For classes of actions, listed in Appendix B, the following conditions are

317

Comparison of Qualitative (AP-913) and Quantitative (Generation Risk Assessment) Equipment Reliability Assessment Techniques  

Science Conference Proceedings (OSTI)

In the analysis of the impact of plant structures, systems and components (SSCs) on nuclear safety and plant generation, both qualitative and quantitative techniques have been employed to classify the functional importance of SSCs and to support prioritization in business decision-making. With respect to the potential impact of SSCs on plant generation, this classification has typically been accomplished via qualitative techniques that support equipment reliability programs and the implementation of INPO...

2006-12-18T23:59:59.000Z

318

Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Ethanol Production Ethanol Production Equipment Tax Exemption to someone by E-mail Share Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on Facebook Tweet about Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on Twitter Bookmark Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on Google Bookmark Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on Delicious Rank Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on Digg Find More places to share Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Ethanol Production Equipment Tax Exemption

319

Wiring methods, components, and equipment for general use. -...  

NLE Websites -- All DOE Office Websites (Extended Search)

to conductors which form an integral part of equipment such as motors, controllers, motor control centers and like equipment. 1926.405(a)(1) General requirements -...

320

Harbin Wind Power Equipment Company | Open Energy Information  

Open Energy Info (EERE)

Login | Sign Up Search Page Edit with form History Facebook icon Twitter icon Harbin Wind Power Equipment Company Jump to: navigation, search Name Harbin Wind Power Equipment...

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

,,,,,,,,,,"Lease Equipment Costs for Primary Oil Production in...  

U.S. Energy Information Administration (EIA) Indexed Site

of Lease Equipment Costs for Primary Oil Recovery ",,,"Oil Production--West Texas" ,,"Operations (10 Producing Wells)" ,,,"Lease Equipment Costs for Primary Oil...

322

1999 Commercial Buildings Characteristics--End-Use Equipment  

Annual Energy Outlook 2012 (EIA)

Energy Consumption Survey Lighting Equipment Standard fluorescent and incandescent light bulbs were the most widely used types of lighting equipment (Figure 3). The vast...

323

A Review of Equipment Aging Theory and Technology  

Science Conference Proceedings (OSTI)

Reviews the theory and technology of equipment aging particularly as they relate to the qualification of safety-system equipment for nuclear power generating stations.

1980-09-01T23:59:59.000Z

324

Avista Utilities (Gas and Electric)- Commercial Food Equipment Rebates  

Energy.gov (U.S. Department of Energy (DOE))

Avista Utilities offers incentives to customers who improve efficiency through electric food service equipment retrofits. A variety of cooking and refrigeration equipment are eligible for rebates...

325

Avista Utilities (Gas & Electric)- Commercial Food Equipment Rebates  

Energy.gov (U.S. Department of Energy (DOE))

Avista Utilities offers incentives to customers who improve efficiency through food service equipment retrofits. A variety of cooking and refrigeration equipment are eligible for rebates through...

326

Alliant Energy Interstate Power and Light - Farm Equipment Energy...  

Open Energy Info (EERE)

Equipment, Ceiling Fan, Clothes Washers, CustomOthers pending approval, Dishwasher, Energy Mgmt. SystemsBuilding Controls, Equipment Insulation, Heat recovery, Lighting,...

327

Management of Sensitive Equipment at Selected Locations, IG-0606...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

use or readily convertible to cash. Generally, this includes equipment such as computers, personal digital assistants, cameras, and communications equipment. The Department...

328

Alternative Fuels Data Center: Electric Vehicle Supply Equipment...  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Electric Vehicle Supply Equipment (EVSE) Incentive - Bay Area to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Incentive - Bay...

329

Advanced Vehicle Testing Activity: Electric Vehicle Supply Equipment...  

NLE Websites -- All DOE Office Websites (Extended Search)

Electric Vehicle Supply Equipment (EVSE) Testing to someone by E-mail Share Advanced Vehicle Testing Activity: Electric Vehicle Supply Equipment (EVSE) Testing on Facebook Tweet...

330

A Methodological Framework for Comparative Assessments of Equipment...  

NLE Websites -- All DOE Office Websites (Extended Search)

Methodological Framework for Comparative Assessments of Equipment Energy Efficiency Policy Measures Title A Methodological Framework for Comparative Assessments of Equipment Energy...

331

Anne Arundel County - Solar and Geothermal Equipment Property...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Other Agencies You are here Home Savings Anne Arundel County - Solar and Geothermal Equipment Property Tax Credit Anne Arundel County - Solar and Geothermal Equipment...

332

Anne Arundel County - Solar and Geothermal Equipment Property...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Other Agencies You are here Home Savings Anne Arundel County - Solar and Geothermal Equipment Property Tax Credits Anne Arundel County - Solar and Geothermal Equipment...

333

Measuring and Test Equipment Assessment Plan,NNSA/Nevada Site...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Measuring and Test Equipment Assessment Plan,NNSANevada Site Office Independent Oversight Division Measuring and Test Equipment Assessment Plan,NNSANevada Site Office Independent...

334

NineStar Connect - Residential Energy Efficient Equipment Rebate...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NineStar Connect - Residential Energy Efficient Equipment Rebate Program NineStar Connect - Residential Energy Efficient Equipment Rebate Program Eligibility Residential Savings...

335

Alternative Fuels Data Center: Electric Vehicle Supply Equipment...  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Electric Vehicle Supply Equipment (EVSE) Rebate - DTE Energy to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - DTE Energy...

336

Changes related to "Nanjing Sunec Wind Generator Equipment Factory...  

Open Energy Info (EERE)

Share this page on Facebook icon Twitter icon Changes related to "Nanjing Sunec Wind Generator Equipment Factory" Nanjing Sunec Wind Generator Equipment Factory Jump...

337

Pages that link to "Nanjing Sunec Wind Generator Equipment Factory...  

Open Energy Info (EERE)

Share this page on Facebook icon Twitter icon Pages that link to "Nanjing Sunec Wind Generator Equipment Factory" Nanjing Sunec Wind Generator Equipment Factory Jump...

338

Category:Smart Grid Projects - Equipment Manufacturing | Open...  

Open Energy Info (EERE)

Smart Grid Projects - Equipment Manufacturing category. Pages in category "Smart Grid Projects - Equipment Manufacturing" The following 2 pages are in this category, out of 2...

339

NSLS Services | Repair & Equipment Services  

NLE Websites -- All DOE Office Websites (Extended Search)

Repair & Equipment Services Repair & Equipment Services Cleaning Facility (BNL Central Shops) Solvent cleaning of vacuum parts and leak checking service is also available. Work is billed to each user via a BNL ILR. Contact the NSLS Building Manager to arrange for any of these services. Electronics Repair Limited repairs for electronic equipment are available from an outside contractor through the Control Room. Contact Control Room Supervisor Randy Church (x2550 or x2736, pager 5310). Shipping memos are filled out on the web, and pick ups are on Fridays. Come to the Control Room for assistance. The user should call the contractor on the day before scheduled pickups to alert the contractor of the pickup. Items to be repaired should be left in the Control Room with the completed shipping memo. Costs are charged to the

340

REMOTE CONTROL EQUIPMENT FOR PLUTONIUM METAL PRODUCTION  

SciTech Connect

Design and construction of remote control equipment for plutonium metal production are described. Criteria for the design of the equipment included the following: rubber gloves were to be completely eliminated; all mechanisms were to be built as integral units to facilitate replacement through use of the plastic- bag technique; no accessory equipment such as switches, valves, piping, or cylinders were to be inside the contaminated enclosure unless required to handle the plutonium; and all units were to be tested in mockups before final design. The chemical process, general layout, and operating function are outlined. Descriptions are given of all mechanical units, electrical systems, hydroxide slurry systems, ventilation systems, and chemical tanks and manifolds. (W.L.H.)

Hazen, W.C.

1951-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Guide to efficient unitary cooling equipment  

SciTech Connect

The universe of unitary cooling equipment is a large one; these systems are used in nearly forty percent of the residential and commercial buildings in the United States. Unitary cooling equipment is made up of off-the-shelf units: factory-assembled single or split systems, including air-source heat pumps and air conditioners. The efficiency of this class of cooling equipment has increased steadily in recent years, driven primarily by government standards. Although most of the units have efficiencies near the minimum federal standards, a significant number of models beat the standards by 10 to 30 percent. However, the larger the system, the narrower the range of efficiencies available and the fewer models available in the most efficient categories. For the buyer and the utility, this report reveals where to get efficiency information on current products, and a recommended purchasing process. It also examines the ratings, standards, and programs that can expand the number of high-efficiency models available.

Gregerson, J.; George, K.L.

1995-07-01T23:59:59.000Z

342

Focus group discussions among owners and non-owners of ground source heat pumps  

SciTech Connect

This research was sponsored by the Office of Buildings and Community Systems and conducted by the Pacific Northwest Laboratory as part of an ongoing effort to enhance the commercial use of federally developed technology. Federal dollars have supported research on the development of ground source heat pumps (GSHP) for several years. Though several companies currently sell GSHP's for residential use, their share of the total heating and air conditioning business remains less than one percent. Large manufacturing companies with national distribution have not yet added GSHP equipment to their product line. GSHP's use only about one half (Braud 1987) to one third (Bose 1987) of the energy needed to operate conventional furnaces and air conditioners. Consequently, a high level of market penetration by the GSHP offers direct benefits to both utility companies and individual users of the systems. Widespread use of these highly efficient systems will reduce both total energy consupmtion, and problems associated with high levels of energy use during peak periods. This will allow utility companies to delay capital expenditures for new facilities to meet the growing energy demand during peak periods. The cost effective use of electricity also reduces the likelihood of homeowners switching to a different fuel source for heating. 5 refs.

Roberson, B.F.

1988-07-01T23:59:59.000Z

343

Colorado Ground Water Commission | Open Energy Information  

Open Energy Info (EERE)

Water Commission Jump to: navigation, search Name Colorado Ground Water Commission Place Colorado Website http:water.state.co.usgroun References Colorado Ground Water Commission...

344

Hanford Site ground-water monitoring for 1993  

Science Conference Proceedings (OSTI)

This report presents the results of the Ground-Water Surveillance Project monitoring for calendar year 1993 on the Hanford Site, Washington. Hanford Site operations from 1943 onward produced large quantities of radiological and chemical waste that have impacted ground-water quality on the Site. Monitoring of water levels and ground-water chemistry is performed to track the extent of contamination and trends in contaminant concentrations. The 1993 monitoring was also designed to identify emerging ground-water quality problems. The information obtained is used to verify compliance with applicable environmental regulations and to evaluate remedial actions. Data from other monitoring and characterization programs were incorporated to provide an integrated assessment of Site ground-water quality. Additional characterization of the Site`s geologic setting and hydrology was performed to support the interpretation of contaminant distributions. Numerical modeling of sitewide ground-water flow also supported the overall project goals. Water-level monitoring was performed to evaluate ground-water flow directions, to track changes in water levels, and to relate such changes to changes in site disposal practices. Water levels over most of the Hanford Site continued to decline between June 1992 and June 1993. The greatest declines occurred in the 200-West Area. These declines are part of the continued response to the cessation of discharge to U Pond and other disposal facilities. The low permeability in this area which enhanced mounding of waste-water discharge has also slowed the response to the reduction of disposal. Water levels remained nearly constant in the vicinity of B Pond, as a result of continued disposal to the pond. Water levels measured from wells in the unconfined aquifer north and east of the Columbia River indicate that the primary source of recharge is irrigation practices.

Dresel, P.E.; Luttrell, S.P.; Evans, J.C. [and others

1994-09-01T23:59:59.000Z

345

Using SVM based method for equipment fault detection in a thermal power plant  

Science Conference Proceedings (OSTI)

Due to the growing demand on electricity, how to improve the efficiency of equipment in a thermal power plant has become one of the critical issues. Reports indicate that efficiency and availability are heavily dependant upon high reliability and maintainability. ... Keywords: Classification, Data mining, Maintenance, Support vector machines, Thermal power

Kai-Ying Chen; Long-Sheng Chen; Mu-Chen Chen; Chia-Lung Lee

2011-01-01T23:59:59.000Z

346

Design/Operations review of core sampling trucks and associated equipment  

SciTech Connect

A systematic review of the design and operations of the core sampling trucks was commissioned by Characterization Equipment Engineering of the Westinghouse Hanford Company in October 1995. The review team reviewed the design documents, specifications, operating procedure, training manuals and safety analysis reports. The review process, findings and corrective actions are summarized in this supporting document.

Shrivastava, H.P.

1996-03-11T23:59:59.000Z

347

Matching equipment size to the cooling load  

SciTech Connect

This article presents a heat extraction rate analysis method, using ASHRAE algorithms that enables HVAC system designers to optimally size cooling equipment. The final stage of the cooling load calculation process determines the heat extraction rate required to achieve design conditions. Put another way, this stage determines the equipment capacity required to match the cooling load profile, and it does so in a manner that predicts the resulting space temperature profile, and it does so in a manner that predicts the resulting space temperature profile. It is a stage in the design process that, in practice, may not be given the attention it deserves.

Bloom, B. (Harvey Toub Engineering, Atlanta, GA (United States))

1993-10-01T23:59:59.000Z

348

Conceptual design report, CEBAF basic experimental equipment  

Science Conference Proceedings (OSTI)

The Continuous Electron Beam Accelerator Facility (CEBAF) will be dedicated to basic research in Nuclear Physics using electrons and photons as projectiles. The accelerator configuration allows three nearly continuous beams to be delivered simultaneously in three experimental halls, which will be equipped with complementary sets of instruments: Hall A--two high resolution magnetic spectrometers; Hall B--a large acceptance magnetic spectrometer; Hall C--a high-momentum, moderate resolution, magnetic spectrometer and a variety of more dedicated instruments. This report contains a short description of the initial complement of experimental equipment to be installed in each of the three halls.

NONE

1990-04-13T23:59:59.000Z

349

Transient analysis of grounding systems  

SciTech Connect

This paper addresses the problem of computing the ground potential rise of grounding systems during transients. Finite element analysis is employed to model the constituent parts of a grounding system. Short lengths of earth embedded electrodes are characterized as transmission lines with distributed inductance, capacitance and leakage resistance to earth. Leakage resistance to earth is accurately computed with the method of moments. The other parameters of the finite element, namely inductance and capacitance, are computed from the resistance utilizing Maxwell's equations. This modeling enables the computation of the transient response of substation grounding systems to fast or slow waves striking the substation. The result is obtained in terms of a convolution of the step response of the system and the striking wave. In this way the impedance of substation systems to 60 cycles is accurately computed. Results demonstrate the dependence of the 60 cycle impedance on system parameters. The methodology allows to interface this model of a substation ground mat with the Electromagnetic Transient Analysis Program thus, allowing explicit representation of earth effects in electromagmatic transients computations.

Meliopoulos, A.P.; Moharam, M.G.

1983-02-01T23:59:59.000Z

350

Electricity used by office equipment and network equipment in the U.S.: Detailed report and appendices  

E-Print Network (OSTI)

LBNL-45917 Electricity Used by Office Equipment and Network46 Electricity Used by Office Equipment and Networkestimates in detail how much electricity is consumed by that

2001-01-01T23:59:59.000Z

351

Industry Recruitment/Support | Open Energy Information  

Open Energy Info (EERE)

Recruitment/Support Recruitment/Support Jump to: navigation, search To promote economic development and the creation of jobs, some states offer financial incentives to recruit or cultivate the manufacturing and development of renewable energy systems and equipment. These incentives commonly take the form of tax credits, tax exemptions and grants. In some cases, the amount of the incentive depends on the amount of eligible equipment that a company manufactures. Most of these incentives apply to several renewable energy technologies, but a few states target specific technologies, such as wind or solar. These incentives are usually designed as temporary measures to support industries in their early years, and they commonly include a sunset provision to encourage the industries to become

352

Ground Magnetics | Open Energy Information  

Open Energy Info (EERE)

Ground Magnetics Ground Magnetics Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Ground Magnetics Details Activities (15) Areas (12) Regions (0) NEPA(1) Exploration Technique Information Exploration Group: Geophysical Techniques Exploration Sub Group: Magnetic Techniques Parent Exploration Technique: Magnetic Techniques Information Provided by Technique Lithology: Presence of magnetic minerals such as magnetite. Stratigraphic/Structural: Mapping of basement structures, horst blocks, fault systems, fracture zones, dykes and intrusions. Hydrological: The circulation of hydrothermal fluid may impact the magnetic susceptibility of rocks. Thermal: Rocks lose their magnetic properties at the Curie temperature (580° C for magnetite) [1] and, upon cooling, remagnetize in the present magnetic field orientation. The Curie point depth in the subsurface may be determined in a magnetic survey to provide information about hydrothermal activity in a region.

353

Test and Test Equipment Joshua Lottich  

E-Print Network (OSTI)

Test and Test Equipment Joshua Lottich CMPE 640 11/23/05 #12;Testing Verifies that manufactured chip meets design specifications. Cannot test for every potential defect. Modeling defects as faults allows for passing and failing of chips. Ideal test would capture all defects and pass only chips

Patel, Chintan

354

Central Waste Complex (CWC) Safety Equipment List  

Science Conference Proceedings (OSTI)

This document lists all safety equipment for the Central Waste Complex, per HNF-PRO-704. This document provides a list of structures, systems, and components that are essential to the continuing safe operation of the Central Waste Complex, as designated by the applicable facility management and the cognizant engineer.

WHITLOCK, R.W.

2000-01-20T23:59:59.000Z

355

PROJECT REPORT HVAC EQUIPMENT DEMOGRAPHICS AND CAPACITY  

E-Print Network (OSTI)

PROJECT REPORT HVAC EQUIPMENT DEMOGRAPHICS AND CAPACITY ANALYSIS TOOLS APPLICABLE TO MULTI Commercial HVAC Design Process 12 5.0 Conclusion 18 6.0 References 19 TABLE OF CONTENTS SECTIONS #12;MULTI performance by collectively improving the enve- lope, lighting and HVAC systems. The primary goals of the UC

California at Davis, University of

356

A cost analysis model for heavy equipment  

Science Conference Proceedings (OSTI)

Total cost is one of the most important factors for a heavy equipment product purchase decision. However, the different cost views and perspectives of performance expectations between the different involved stakeholders may cause customer relation problems ... Keywords: Cost responsibilities, Operating costs, Ownership costs, Post-Manufacturing Product Cost (PMPC), System life-cycle cost

Shibiao Chen; L. Ken Keys

2009-05-01T23:59:59.000Z

357

Ground-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report  

DOE Green Energy (OSTI)

The energy service needs of a net-zero-energy house (ZEH) include space heating and cooling, water heating, ventilation, dehumidification, and humidification, depending on the requirements of the specific location. These requirements differ in significant ways from those of current housing. For instance, the most recent DOE buildings energy data (DOE/BED 2007) indicate that on average {approx}43% of residential buildings primary energy use is for space heating and cooling, vs. {approx}12% for water heating (about a 3.6:1 ratio). In contrast, for the particular prototype ZEH structures used in the analyses in this report, that ratio ranges from about 0.3:1 to 1.6:1 depending on location. The high-performance envelope of a ZEH results in much lower space heating and cooling loads relative to current housing and also makes the house sufficiently air-tight to require mechanical ventilation for indoor air quality. These envelope characteristics mean that the space conditioning load will be closer in size to the water heating load, which depends on occupant behavior and thus is not expected to drop by any significant amount because of an improved envelope. In some locations such as the Gulf Coast area, additional dehumidification will almost certainly be required during the shoulder and cooling seasons. In locales with heavy space heating needs, supplemental humidification may be needed because of health concerns or may be desired for improved occupant comfort. The U.S. Department of Energy (DOE) has determined that achieving their ZEH goal will require energy service equipment that can meet these needs while using 50% less energy than current equipment. One promising approach to meeting this requirement is through an integrated heat pump (IHP) - a single system based on heat pumping technology. The energy benefits of an IHP stem from the ability to utilize otherwise wasted energy; for example, heat rejected by the space cooling operation can be used for water heating. With the greater energy savings the cost of the more energy efficient components required for the IHP can be recovered more quickly than if they were applied to individual pieces of equipment to meet each individual energy service need. An IHP can be designed to use either outdoor air or geothermal resources (e.g., ground, ground water, surface water) as the environmental energy source/sink. Based on a scoping study of a wide variety of possible approaches to meeting the energy service needs for a ZEH, DOE selected the IHP concept as the most promising and has supported research directed toward the development of both air- and ground-source versions. This report describes the ground-source IHP (GS-IHP) design and includes the lessons learned and best practices revealed by the research and development (R&D) effort throughout. Salient features of the GS-IHP include a variable-speed rotary compressor incorporating a brushless direct current permanent magnet motor which provides all refrigerant compression, a variable-speed fan for the indoor section, a multiple-speed ground coil circuit pump, and a single-speed pump for water heating operation. Laboratory IHP testing has thus far used R-22 because of the availability of the needed components that use this refrigerant. It is expected that HFC R-410A will be used for any products arising from the IHP concept. Data for a variable-speed compressor that uses R-410A has been incorporated into the DOE/ORNL Mark VI Heat Pump Design Model (HPDM). HPDM was then linked to TRNSYS, a time-series-dependent simulation model capable of determining the energy use of building cooling and heating equipment as applied to a defined house on a sub-hourly basis. This provided a highly flexible design analysis capability for advanced heat pump equipment; however, the program also took a relatively long time to run. This approach was used with the initial prototype design reported in Murphy et al. (2007a) and in the business case analysis of Baxter (2007).

Murphy, Richard W [ORNL; Rice, C Keith [ORNL; Baxter, Van D [ORNL; Craddick, William G [ORNL

2007-09-01T23:59:59.000Z

358

Ground Truth: A Positive Cloud-to-Ground Lightning Flash  

Science Conference Proceedings (OSTI)

We describe the circumstances and effects of a cloud-to-ground lightning flash that lowered positive charge and struck a residential home near Albany, New York. The characteristics of the flash were detected and recorded by a wide-band magnetic ...

Vincent P. Idone; Richard E. Orville; Ronald W. Henderson

1984-07-01T23:59:59.000Z

359

Ground states in complex bodies  

E-Print Network (OSTI)

A unified framework for analyzing the existence of ground states in wide classes of elastic complex bodies is presented here. The approach makes use of classical semicontinuity results, Sobolev mappinngs and Cartesian currents. Weak diffeomorphisms are used to represent macroscopic deformations. Sobolev maps and Cartesian currents describe the inner substructure of the material elements. Balance equations for irregular minimizers are derived. A contribution to the debate about the role of the balance of configurational actions follows. After describing a list of possible applications of the general results collected here, a concrete discussion of the existence of ground states in thermodynamically stable quasicrystals is presented at the end.

Paolo Maria Mariano; Giuseppe Modica

2008-02-11T23:59:59.000Z

360

LINE-ABOVE-GROUND ATTENUATOR  

DOE Patents (OSTI)

The line-above-ground attenuator provides a continuously variable microwave attenuator for a coaxial line that is capable of high attenuation and low insertion loss. The device consists of a short section of the line-above- ground plane type transmission lime, a pair of identical rectangular slabs of lossy material like polytron, whose longitudinal axes are parallel to and indentically spaced away from either side of the line, and a geared mechanism to adjust amd maintain this spaced relationship. This device permits optimum fineness and accuracy of attenuator control which heretofore has been difficult to achieve.

Wilds, R.B.; Ames, J.R.

1957-09-24T23:59:59.000Z

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Feasibility of gas-phase decontamination of gaseous diffusion equipment  

SciTech Connect

The five buildings at the K-25 Site formerly involved in the gaseous diffusion process contain 5000 gaseous diffusion stages as well as support facilities that are internally contaminated with uranium deposits. The gaseous diffusion facilities located at the Portsmouth Gaseous Diffusion Plant and the Paducah Gaseous Diffusion Plant also contain similar equipment and will eventually close. The decontamination of these facilities will require the most cost-effective technology consistent with the criticality, health physics, industrial hygiene, and environmental concerns; the technology must keep exposures to hazardous substances to levels as low as reasonably achievable (ALARA). This report documents recent laboratory experiments that were conducted to determine the feasibility of gas-phase decontamination of the internal surfaces of the gaseous diffusion equipment that is contaminated with uranium deposits. A gaseous fluorinating agent is used to fluorinate the solid uranium deposits to gaseous uranium hexafluoride (UF{sub 6}), which can be recovered by chemical trapping or freezing. The lab results regarding the feasibility of the gas-phase process are encouraging. These results especially showed promise for a novel decontamination approach called the long-term, low-temperature (LTLT) process. In the LTLT process: The equipment is rendered leak tight, evacuated, leak tested, and pretreated, charged with chlorine trifluoride (ClF{sub 3}) to subatmospheric pressure, left for an extended period, possibly > 4 months, while processing other items. Then the UF{sub 6} and other gases are evacuated. The UF{sub 6} is recovered by chemical trapping. The lab results demonstrated that ClF{sub 3} gas at subatmospheric pressure and at {approx} 75{degree}F is capable of volatilizing heavy deposits of uranyl fluoride from copper metal surfaces sufficiently that the remaining radioactive emissions are below limits.

Munday, E.B.; Simmons, D.W.

1993-02-01T23:59:59.000Z

362

DARPA Learning Applied to Ground Robots (LAGR)  

Science Conference Proceedings (OSTI)

DARPA Learning Applied to Ground Robots (LAGR) Project (Concluded). Summary: The National Institute of Standards ...

2012-01-04T23:59:59.000Z

363

Particle size distributions of ground corn and DDGS from dry grind processing  

E-Print Network (OSTI)

ABSTRACT. Ethanol production has increased in the past decade as a result of growth in the dry grind industry. In the dry grind process, the first step is grinding of corn. The particle size of the resulting ground corn can affect the fermentation process and the particle size of dried distillers ’ grains with solubles (DDGS), a coproduct of dry grind processing. Few data are available that characterize particle size distributions of ground corn or DDGS. The objective was to determine particle size distributions of ground corn and DDGS. Samples of ground corn and DDGS were obtained from nine dry grind plants; particle size distribution, geometric mean diameter (dgw) and geometric standard deviation (Sgw) were determined. The dgw of ground corn and of DDGS were not different among processing plants. The overall mean dgw of ground corn was not different from that of DDGS. Most of the ground corn (80 g/100 g) and DDGS (70 g/100 g) were recovered in the three largest particle size categories. The particle size distributions of ground corn were not correlated (r Corn, DDGS, Distillers dried grains with solubles, Ethanol. Corn is processed into ethanol by one of two major processes: dry grinding or wet milling. Wet milling is more complex than dry grinding because fiber and germ components are separated; this requires considerable equipment and capital. In the dry grind process,

K. D. Rausch; R. L. Belyea; M. R. Ellersieck; V. Singh; D. B. Johnston; M. E. Tumbleson

2005-01-01T23:59:59.000Z

364

Building Technologies Office: About the Appliance and Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

About the Appliance and About the Appliance and Equipment Standards Program to someone by E-mail Share Building Technologies Office: About the Appliance and Equipment Standards Program on Facebook Tweet about Building Technologies Office: About the Appliance and Equipment Standards Program on Twitter Bookmark Building Technologies Office: About the Appliance and Equipment Standards Program on Google Bookmark Building Technologies Office: About the Appliance and Equipment Standards Program on Delicious Rank Building Technologies Office: About the Appliance and Equipment Standards Program on Digg Find More places to share Building Technologies Office: About the Appliance and Equipment Standards Program on AddThis.com... About History & Impacts Statutory Authorities & Rules Regulatory Processes

365

Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Electric Vehicle Electric Vehicle Supply Equipment (EVSE) Regulation Exemption to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Regulation Exemption on Facebook Tweet about Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Regulation Exemption on Twitter Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Regulation Exemption on Google Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Regulation Exemption on Delicious Rank Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Regulation Exemption on Digg Find More places to share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Regulation Exemption on AddThis.com...

366

Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Electric Vehicle Electric Vehicle Supply Equipment (EVSE) Requirements to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Facebook Tweet about Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Twitter Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Google Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Delicious Rank Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Digg Find More places to share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on AddThis.com... More in this section... Federal State Advanced Search

367

Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Electric Vehicle Electric Vehicle Supply Equipment (EVSE) Installation Requirements to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Facebook Tweet about Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Twitter Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Google Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Delicious Rank Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Digg Find More places to share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Installation Requirements on AddThis.com...

368

Alternative Fuels Data Center: Biodiesel Production and Blending Equipment  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Biodiesel Production Biodiesel Production and Blending Equipment Tax Credit to someone by E-mail Share Alternative Fuels Data Center: Biodiesel Production and Blending Equipment Tax Credit on Facebook Tweet about Alternative Fuels Data Center: Biodiesel Production and Blending Equipment Tax Credit on Twitter Bookmark Alternative Fuels Data Center: Biodiesel Production and Blending Equipment Tax Credit on Google Bookmark Alternative Fuels Data Center: Biodiesel Production and Blending Equipment Tax Credit on Delicious Rank Alternative Fuels Data Center: Biodiesel Production and Blending Equipment Tax Credit on Digg Find More places to share Alternative Fuels Data Center: Biodiesel Production and Blending Equipment Tax Credit on AddThis.com... More in this section... Federal State

369

HVAC equipment replacement for best size and efficiency  

DOE Green Energy (OSTI)

The purpose of this project was to explore the potential benefits of HVAC equipment replacement for buildings owned by the City of Phoenix. The specific research objectives were as follows: Establishment an understanding of the magnitude and sources of saving available through equipment replacement; Establish an economic model for understanding equipment replacement and deciding when equipment should be replaced; Establish technical methods for calculating savings from replacement of various types of equipment; Demonstrate the replacement of a major item of HVAC equipment and document the savings through actual experimentation and measurement; and Provide guidance material for other jurisdictions wishing to investigate equipment replacement. 11 figs., 9 tabs.

Teji, D.S.

1988-02-01T23:59:59.000Z

370

Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Electric Vehicle Electric Vehicle Supply Equipment (EVSE) Requirements to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Facebook Tweet about Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Twitter Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Google Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Delicious Rank Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Digg Find More places to share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on AddThis.com... More in this section... Federal State Advanced Search

371

Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Electric Vehicle Electric Vehicle Supply Equipment (EVSE) Rebate - LADWP to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - LADWP on Facebook Tweet about Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - LADWP on Twitter Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - LADWP on Google Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - LADWP on Delicious Rank Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - LADWP on Digg Find More places to share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - LADWP on AddThis.com... More in this section... Federal

372

Alternative Fuels Data Center: Mandatory Electric Vehicle Supply Equipment  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Mandatory Electric Mandatory Electric Vehicle Supply Equipment (EVSE) Building Standards to someone by E-mail Share Alternative Fuels Data Center: Mandatory Electric Vehicle Supply Equipment (EVSE) Building Standards on Facebook Tweet about Alternative Fuels Data Center: Mandatory Electric Vehicle Supply Equipment (EVSE) Building Standards on Twitter Bookmark Alternative Fuels Data Center: Mandatory Electric Vehicle Supply Equipment (EVSE) Building Standards on Google Bookmark Alternative Fuels Data Center: Mandatory Electric Vehicle Supply Equipment (EVSE) Building Standards on Delicious Rank Alternative Fuels Data Center: Mandatory Electric Vehicle Supply Equipment (EVSE) Building Standards on Digg Find More places to share Alternative Fuels Data Center: Mandatory Electric Vehicle Supply Equipment (EVSE) Building Standards on

373

Power levels in office equipment: Measurements of new monitors and personal computers  

SciTech Connect

Electronic office equipment has proliferated rapidly over the last twenty years and is projected to continue growing in the future. Efforts to reduce the growth in office equipment energy use have focused on power management to reduce power consumption of electronic devices when not being used for their primary purpose. The EPA ENERGY STAR[registered trademark] program has been instrumental in gaining widespread support for power management in office equipment, and accurate information about the energy used by office equipment in all power levels is important to improving program design and evaluation. This paper presents the results of a field study conducted during 2001 to measure the power levels of new monitors and personal computers. We measured off, on, and low-power levels in about 60 units manufactured since July 2000. The paper summarizes power data collected, explores differences within the sample (e.g., between CRT and LCD monitors), and discusses some issues that arise in m etering office equipment. We also present conclusions to help improve the success of future power management programs.Our findings include a trend among monitor manufacturers to provide a single very low low-power level, and the need to standardize methods for measuring monitor on power, to more accurately estimate the annual energy consumption of office equipment, as well as actual and potential energy savings from power management.

Roberson, Judy A.; Brown, Richard E.; Nordman, Bruce; Webber, Carrie A.; Homan, Gregory H.; Mahajan, Akshay; McWhinney, Marla; Koomey, Jonathan G.

2002-05-14T23:59:59.000Z

374

STLOAD 1.0, Substation Equipment Thermal Loading Program  

Science Conference Proceedings (OSTI)

The Substation Equipment Thermal Loading Program, STLOAD Version 1.0 software is intended for use by substation engineers for the purpose of establishing thermal ratings for and making diagnostic evaluations of substation equipment. STLOAD 1.0 software calculates substation equipment operating temperatures and thermal ratings based on user-specified physical parameters for the equipment and user-specified load and air temperature data. Substation equipment that can be modeled using STLOAD includes strain...

2006-03-15T23:59:59.000Z

375

Evaluation of using cyclocranes to support drilling and production of oil and gas in wetland areas. Fourth quarterly technical progress report, Second quarter, 1993  

SciTech Connect

The planned program falls under wetlands area research related to drilling, production, and transportation of oil and gas resources. Specifically the planned program addresses an evaluation of using cyclocraft to transport drill rigs, mud, pipes and other materials and equipment in a cost effective and environmentally safe manner to support oil and gas drilling and production operations in wetland areas. The cyclocraft is a proven hybrid aircraft that utilizes aerostatic and aerodynamic lift. This type of aircraft has considerable payload capacity, VTOL capability, high controllability, low operating cost, low downwash and high safety. The benefits of using a cyclocraft to transport drill rigs and materials over environmentally-sensitive surfaces would be significant. The cyclocraft has considerable cost and operational advantages over the helicopter. The major activity during the second quarter of 1993 was focussed on completion of Task 4, Preliminary Design. The selected design has been designated H.1 Cyclocraft by MRC. Also during the report period, Task 6, Ground Support, was completed and a report containing the results was submitted to DOE. This task addressed the complete H.1 Cyclocraft system, i.e. it included the need personnel, facilities and equipment to support cyclocraft operations in wetland areas.

Eggington, W.J.

1993-09-01T23:59:59.000Z

376

Sample Environment Equipment Categories - ORNL Neutron Sciences  

NLE Websites -- All DOE Office Websites (Extended Search)

Home › Instruments › Sample Environment Home › Instruments › Sample Environment Sample Environment: Categories of Equipment All Ancillary Equipment Auto Changer Closed Cycle Refrigerators Closed Cycle Refrigerators - Bottom Loading Closed Cycle Refrigerators - Top Loading Furnaces Gas Handling Gas Panel High Pressure Systems Liquid Helium Cryostats Magnet Systems Other Special Environments Sample Cell Sample Stick Ultra Low Temperature Devices Sample Environment: by Beam Line All BL-11A-POWGEN BL-11B-MANDI BL-12-TOPAZ BL-13-Fundamental Neutron Physics Beam Line BL-14A-BL-14A BL-14B-HYSPEC BL-15-Neutron Spin Echo (NSE) BL-16B-VISION BL-17-SEQUOIA BL-18-ARCS BL-1A-TOF-USANS BL-1B-NOMAD BL-2-BASIS BL-3-SNAP BL-4A-Magnetism Reflectometer BL-4B-Liquids Reflectometer BL-5-Cold Neutron Chopper Spectrometer (CNCS) BL-6-EQ-SANS

377

Laboratory Equipment Donation Program - Guidelines/FAQ  

Office of Scientific and Technical Information (OSTI)

Frequently Asked Questions Frequently Asked Questions Who is eligible to apply for equipment? Due to budget constraints, the free shipping program for "high need schools" has been discontinued; and middle and high schools are no longer eligible to participate in the Laboratory Equipment Donation Program (LEDP) program. Participation in the LEDP is limited to accredited, post graduate, degree granting institutions including universities, colleges, junior colleges, technical institutes, museums, or hospitals, located in the U.S. and interested in establishing or upgrading energy-oriented educational programs in the life, physical, and environmental sciences and in engineering is eligible to apply. An energy-oriented program is defined as an academic research activity dealing primarily or entirely in

378

Process Equipment Cost Estimation, Final Report  

Office of Scientific and Technical Information (OSTI)

Process Equipment Cost Estimation Process Equipment Cost Estimation Final Report January 2002 H.P. Loh U.S. Department of Energy National Energy Technology Laboratory P.O. Box 10940, 626 Cochrans Mill Road Pittsburgh, PA 15236-0940 and P.O. Box 880, 3610 Collins Ferry Road Morgantown, WV 26507-0880 and Jennifer Lyons and Charles W. White, III EG&G Technical Services, Inc. 3604 Collins Ferry Road, Suite 200 Morgantown, WV 26505 DOE/NETL-2002/1169 ii Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus,

379

Documentation Requirements for Pressurized Experiment Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

Documentation Requirements for Pressurized Experiment Apparatus Documentation Requirements for Pressurized Experiment Apparatus PSSC NOTE01 15-Jan-2013 When bringing a piece of apparatus to the APS for an experiment that will involve pressure, whether it is to be used on a beamline during a measurement or in a laboratory to prepare the sample prior to the experiment, the hazards associated with the equipment must be reviewed. To review the equipment and make any recommendations, a certain level of documentation must be provided by the experimenter. The length and depth of the documentation should be commensurate with the complexity of the system. 1. Description of apparatus a. Description of the assembly and operation of the system. b. State the maximum working pressure, working fluid (liquid or gas) used to

380

Equipment Reliability Site-Wide Training - Korean Release (ER Site-Wide Training - Korean Release) 1.0  

Science Conference Proceedings (OSTI)

Equipment Reliability Site-Wide Training is a computer based training module that allows users to access training when desired and review it at their own pace. It provides graphics and interactive features to enhance learning. This training will support EPRInuclear utility members by raising awareness of personnel in various organizations as to their roles and responsibilities related to equipment reliability and focus attention on critical components and single point vulnerabilities within nuclear power...

2011-12-05T23:59:59.000Z

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Electrical Properties of Carbon Fiber Support Systems  

E-Print Network (OSTI)

Carbon fiber support structures have become common elements of detector designs for high energy physics experiments. Carbon fiber has many mechanical advantages but it is also characterized by high conductivity, particularly at high frequency, with associated design issues. This paper discusses the elements required for sound electrical performance of silicon detectors employing carbon fiber support elements. Tests on carbon fiber structures are presented indicating that carbon fiber must be regarded as a conductor for the frequency region of 10 to 100 MHz. The general principles of grounding configurations involving carbon fiber structures will be discussed. To illustrate the design requirements, measurements performed with a silicon detector on a carbon fiber support structure at small radius are presented. A grounding scheme employing copper-kapton mesh circuits is described and shown to provide adequate and robust detector performance.

W. Cooper; C. Daly; M. Demarteau; J. Fast; K. Hanagaki; M. Johnson; W. Kuykendall; H. Lubatti; M. Matulik; A. Nomerotski; B. Quinn; J. Wang

2005-04-19T23:59:59.000Z

382

Electrical Properties of Carbon Fiber Support Systems  

E-Print Network (OSTI)

Carbon fiber support structures have become common elements of detector designs for high energy physics experiments. Carbon fiber has many mechanical advantages but it is also characterized by high conductivity, particularly at high frequency, with associated design issues. This paper discusses the elements required for sound electrical performance of silicon detectors employing carbon fiber support elements. Tests on carbon fiber structures are presented indicating that carbon fiber must be regarded as a conductor for the frequency region of 10 to 100 MHz. The general principles of grounding configurations involving carbon fiber structures will be discussed. To illustrate the design requirements, measurements performed with a silicon detector on a carbon fiber support structure at small radius are presented. A grounding scheme employing copper-kapton mesh circuits is described and shown to provide adequate and robust detector performance.

Cooper, W; Demarteau, M; Fast, J; Hanagaki, K; Johnson, M; Kuykendall, W; Lubatti, H; Matulik, M; Nomerotski, A; Quinn, B; Wang, J

2005-01-01T23:59:59.000Z

383

Measured Peak Equipment Loads in Laboratories  

SciTech Connect

This technical bulletin documents measured peak equipment load data from 39 laboratory spaces in nine buildings across five institutions. The purpose of these measurements was to obtain data on the actual peak loads in laboratories, which can be used to rightsize the design of HVAC systems in new laboratories. While any given laboratory may have unique loads and other design considerations, these results may be used as a 'sanity check' for design assumptions.

Mathew, Paul A.

2007-09-12T23:59:59.000Z

384

Miscellaneous equipment in commercial buildings: The inventory, utilization, and consumption by equipment type  

SciTech Connect

The nature of the miscellaneous equipment (devices other than permanently installed lighting and those used for space conditioning) in commercial buildings is diverse, comprising a wide variety of devices that are subject to varied patterns of use. This portion of the commercial load is frequently underestimated, and widely hypothesized to be growing. These properties make it a particularly difficult load to characterize for purposes of demand-side management. In the End-Use Load and Consumer Assessment Program (ELCAP), over 100 commercial sites in the Pacific Northwest have been metered at the end-use level for several years. Detailed inspections of the equipment in them have also been conducted. This paper describes how the ELCAP data have been used to estimate three fundamental properties of the various types of equipment in several classes of commercial buildings: (1) the installed capacity per unit floor area, (2) utilization of the equipment relative to the installed capacity, and (3) the resulting energy consumption by building type and for the Pacific Northwest commercial sector as a whole. Applications for the results include assessment of conservation potential, prediction of equipment loads from survey data, estimating equipment loads for energy audits, targeting of conservation technology development, and disaggregating building total or mixed end-use data. 4 tabs., refs.

Pratt, R.G.; Williamson, M.A.; Richman, E.E.

1990-09-01T23:59:59.000Z

385

P ORNiiTM-7004 Results of Ground Level Radiation  

Office of Legacy Management (LM)

ORNiiTM-7004 ORNiiTM-7004 Results of Ground Level Radiation Measurements in Support of the 1978 Aerial Survey of the Lake Ontario Ordnance W o rks, Lewiston, New York _ ict~~.. By A, grven _, ,_~ ~.~ _,. :::;(' ~. . ' -- .- ,. R. W . Doane F. F. Haywood W . H. Shinpaugh ORNL/TM-7004 Dist. Category UC-41 Contract No. W-7405eng-26 RESULTS OF GROUND LEVEL RADIATION MEASUREMENTS IN SUPPORT OF THE 1978 AERIAL SURVEY OF THE LAKE ONTARIO ORDNANCE WORKS, LEWISTON, NEW YORK B. A. Berven F. F. Haywood R. W. Doane W. H. Shinpaugh Work performed by Health and Safety Research Division Date Published: September 1979 Oak Ridge National Laboratory Oak Ridge, Tennessee 37830 operated by UNION CARBIDE CORPORATION for the DEPARTMENT OF ENERGY as part of the Formerly Utilized Sites -

386

Development of a Residential Ground-Source Integrated Heat Pump  

Science Conference Proceedings (OSTI)

A residential-size ground-source integrated heat pump (GSIHP) system has been developed and is currently being field tested. The system is a nominal 2-ton (7 kW) cooling capacity, variable-speed unit, which is multi-functional, e.g. space cooling, space heating, dedicated water heating, and simultaneous space cooling and water heating. High-efficiency brushless permanent-magnet (BPM) motors are used for the compressor, indoor blower, and pumps to obtain the highest component performance and system control flexibility. Laboratory test data were used to calibrate a vapor-compression simulation model (HPDM) for each of the four primary modes of operation. The model was used to optimize the internal control options and to simulate the selected internal control strategies, such as controlling to a constant air supply temperature in the space heating mode and a fixed water temperature rise in water heating modes. Equipment performance maps were generated for each operation mode as functions of all independent variables for use in TRNSYS annual energy simulations. These were performed for the GSIHP installed in a well-insulated 2600 ft2(242 m2) house and connected to a vertical ground loop heat exchanger(GLHE). We selected a 13 SEER (3.8 CSPF )/7.7 HSPF (2.3 HSPF, W/W) ASHP unit with 0.90 Energy Factor (EF) resistance water heater as the baseline for energy savings comparisons. The annual energy simulations were conducted over five US climate zones. In addition, appropriate ground loop sizes were determined for each location to meet 10-year minimum and maximum design entering water temperatures (EWTs) to the equipment. The prototype GSIHP system was predicted to use 52 to 59% less energy than the baseline system while meeting total annual space conditioning and water heating loads.

Rice, C Keith [ORNL; Baxter, Van D [ORNL; Hern, Shawn [ClimateMaster, Inc.; McDowell, Tim [Thermal Energy System Specialists, LLC; Munk, Jeffrey D [ORNL; Shen, Bo [ORNL

2013-01-01T23:59:59.000Z

387

BCM 1 Equipment Inventory | Sample Preparation Laboratories  

NLE Websites -- All DOE Office Websites (Extended Search)

1 Equipment Inventory 1 Equipment Inventory « Biology Chemistry & Material Science Laboratory 1 Title Equipment Type Description Agilent 8453 UV-Vis Spectrophotometer Analytical Agilent 8453 UV-VIS diode-array spectrophotometer. Wavelength range 190-1100 nm with a 1 nm optical slit width. Disposable plastic cuvettes are available in the lab, and quartz cuvettes and microcuvettes are available on a check-out basis. Beckman GPKR Centrifuge Centrifuge Beckman GPKR refrigerated centrifuge with fixed angle rotor, 8000 rpm max speed, temperature range -10°C to 40°C, fits 50mL tubes. Corning 430 pH Meter pH Meter The Corning 430 pH meter is designed to handle laboratory applications from the most routine to the highly complex. Encased in spill-resistant housings and feature chemical-resistant, sealed keypad. Model 430 (pH range 0.00 to 14.00) is a basic, yet reliable meter providing accurate, efficient digital measurements. Offers simplified, four-button operation, automatic calibration and temperature compensation, % slope readout, self-diagnostics test on powerup and analog recorder output. Unique LCD shows pH, mV

388

Plant design: Integrating Plant and Equipment Models  

Science Conference Proceedings (OSTI)

Like power plant engineers, process plant engineers must design generating units to operate efficiently, cleanly, and profitably despite fluctuating costs for raw materials and fuels. To do so, they increasingly create virtual plants to enable evaluation of design concepts without the expense of building pilot-scale or demonstration facilities. Existing computational models describe an entire plant either as a network of simplified equipment models or as a single, very detailed equipment model. The Advanced Process Engineering Co-Simulator (APECS) project (Figure 5) sponsored by the U.S. Department of Energy's National Energy Technology Laboratory (NETL) seeks to bridge the gap between models by integrating plant modeling and equipment modeling software. The goal of the effort is to provide greater insight into the performance of proposed plant designs. The software integration was done using the process-industry standard CAPE-OPEN (Computer Aided Process Engineering–Open), or CO interface. Several demonstration cases based on operating power plants confirm the viability of this co-simulation approach.

Sloan, David (Alstrom Power); Fiveland, Woody (Alstrom Power); Zitney, S.E.; Osawe, Maxwell (Ansys, Inc.)

2007-08-01T23:59:59.000Z

389

Decontamination & Decommissioning Equipment Tracking System (DDETS)  

SciTech Connect

At the request of the Department of Energy (DOE)(EM-50), the Scientific Computing Unit developed a prototype system to track information and data relevant to equipment and tooling removed during decontamination and decommissioning activities. The DDETS proof-of-concept tracking system utilizes a one-dimensional (1D) and two-dimensional (2D) bar coding technology to retain and track information such as identification number, manufacturer, requisition information, and various contaminant information, etc. The information is encoded in a bar code, printed on a label and can be attached to corresponding equipment. The DDETS was developed using a proven relational database management system which allows the addition, modification, printing, and deletion of data. In addition, communication interfaces with bar code printers and bar code readers were developed. Additional features of the system include: (a) Four different reports available for the user (REAPS, transaction, and two inventory), (b) Remote automated inventory tracking capabilities, (c) Remote automated inventory tracking capability (2D bar codes allow equipment to be scanned/tracked without being linked to the DDETS database), (d) Edit, update, delete, and query capabilities, (e) On-line bar code label printing utility (data from 2D bar codes can be scanned directly into the data base simplifying data entry), and (f) Automated data backup utility. Compatibility with the Reportable Excess Automated Property System (REAPS) to upload data from DDETS is planned.

Cook, S.

1994-07-01T23:59:59.000Z

390

Contracting for Support Services | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Contracting for Support Services Contracting for Support Services Contracting for Support Services What you need to know as a Federal Employee The Department of Energy, like most Federal agencies, spends a significant amount of its contracting budget on support services. While these contracts fulfill continuing and essential needs of the Department, this type of contracting arrangement can present unique situations that require special diligence on the part of Federal employees to ensure that applicable statutes, regulations, and management practices are followed. Contracts for support services cover a wide range of areas and may include: Maintenance, overhaul, repair and servicing of equipment. Housekeeping services. Advisory and assistance services. Transportation services. Recurring maintenance of real property.

391

Alternative Fuels Data Center: Biodiesel Equipment and Fuel Tax Exemption  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Biodiesel Equipment Biodiesel Equipment and Fuel Tax Exemption to someone by E-mail Share Alternative Fuels Data Center: Biodiesel Equipment and Fuel Tax Exemption on Facebook Tweet about Alternative Fuels Data Center: Biodiesel Equipment and Fuel Tax Exemption on Twitter Bookmark Alternative Fuels Data Center: Biodiesel Equipment and Fuel Tax Exemption on Google Bookmark Alternative Fuels Data Center: Biodiesel Equipment and Fuel Tax Exemption on Delicious Rank Alternative Fuels Data Center: Biodiesel Equipment and Fuel Tax Exemption on Digg Find More places to share Alternative Fuels Data Center: Biodiesel Equipment and Fuel Tax Exemption on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Biodiesel Equipment and Fuel Tax Exemption

392

Alternative Fuels Data Center: Installing New E85 Equipment  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Installing New E85 Installing New E85 Equipment to someone by E-mail Share Alternative Fuels Data Center: Installing New E85 Equipment on Facebook Tweet about Alternative Fuels Data Center: Installing New E85 Equipment on Twitter Bookmark Alternative Fuels Data Center: Installing New E85 Equipment on Google Bookmark Alternative Fuels Data Center: Installing New E85 Equipment on Delicious Rank Alternative Fuels Data Center: Installing New E85 Equipment on Digg Find More places to share Alternative Fuels Data Center: Installing New E85 Equipment on AddThis.com... More in this section... Ethanol Basics Benefits & Considerations Stations Locations Infrastructure Development Business Case Equipment Options Equipment Installation Codes, Standards, & Safety Vehicles Laws & Incentives

393

Alternative Fuels Data Center: Biofuel Blending Equipment Tax Exemption  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Blending Blending Equipment Tax Exemption to someone by E-mail Share Alternative Fuels Data Center: Biofuel Blending Equipment Tax Exemption on Facebook Tweet about Alternative Fuels Data Center: Biofuel Blending Equipment Tax Exemption on Twitter Bookmark Alternative Fuels Data Center: Biofuel Blending Equipment Tax Exemption on Google Bookmark Alternative Fuels Data Center: Biofuel Blending Equipment Tax Exemption on Delicious Rank Alternative Fuels Data Center: Biofuel Blending Equipment Tax Exemption on Digg Find More places to share Alternative Fuels Data Center: Biofuel Blending Equipment Tax Exemption on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Biofuel Blending Equipment Tax Exemption Qualified equipment used for storing and blending petroleum-based fuel with

394

GTA (ground test accelerator) Phase 1: Baseline design report  

DOE Green Energy (OSTI)

The national Neutral Particle Beam (NPB) program has two objectives: to provide the necessary basis for a discriminator/weapon decision by 1992, and to develop the technology in stages that lead ultimately to a neutral particle beam weapon. The ground test accelerator (GTA) is the test bed that permits the advancement of the state-of-the-art under experimental conditions in an integrated automated system mode. An intermediate goal of the GTA program is to support the Integrated Space Experiments, while the ultimate goal is to support the 1992 decision. The GTA system and each of its major subsystems are described, and project schedules and resource requirements are provided. (LEW)

Not Available

1986-08-01T23:59:59.000Z

395

Ground test facility for nuclear testing of space reactor subsystems  

SciTech Connect

Two major reactor facilities at the INEL have been identified as easily adaptable for supporting the nuclear testing of the SP-100 reactor subsystem. They are the Engineering Test Reactor (ETR) and the Loss of Fluid Test Reactor (LOFT). In addition, there are machine shops, analytical laboratories, hot cells, and the supporting services (fire protection, safety, security, medical, waste management, etc.) necessary to conducting a nuclear test program. This paper presents the conceptual approach for modifying these reactor facilities for the ground engineering test facility for the SP-100 nuclear subsystem. 4 figs.

Quapp, W.J.; Watts, K.D.

1985-01-01T23:59:59.000Z

396

Biodiesel Emissions Testing with a Modern Diesel Engine - Equipment Only: Cooperative Research and Development Final Report, CRADA Number CRD-10-399  

DOE Green Energy (OSTI)

To evaluate the emissions and performance impact of biodiesel in a modern diesel engine equipped with a diesel particulate filter. This testing is in support of the Non-Petroleum Based Fuels (NPBF) 2010 Annual Operating Plan (AOP).

Williams, A.

2013-06-01T23:59:59.000Z

397

Ground Magnetics (Nannini, 1986) | Open Energy Information  

Open Energy Info (EERE)

Ground Magnetics (Nannini, 1986) Ground Magnetics (Nannini, 1986) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: Ground Magnetics (Nannini, 1986) Exploration Activity Details Location Unspecified Exploration Technique Ground Magnetics Activity Date Usefulness not indicated DOE-funding Unknown Notes Detection and quantitative assessment of such intrusive events can be facilitated by magnetic surveys (ground or aerial magnetic field measurements). These surveys are based on the magnetic susceptibility contrast between magmatic rocks at depth and the sedimentary formations above. References Raffaello Nannini (1986) Some Aspects Of Exploration In Non-Volcanic Areas Retrieved from "http://en.openei.org/w/index.php?title=Ground_Magnetics_(Nannini,_1986)&oldid=388291

398

A cathodically protected electrical substation ground grid  

SciTech Connect

This paper presents a discussion on the design of a cathodically protected electrical substation grounding system in which a steel ground grid and steel ground rods were used in place of the commonly used copper ground grid and copperweld ground rods. Several electrical constraints are presented which discuss common electrical utility requirements, safety considerations and economic factors. The grounding system materials which were chosen are discussed along with the means of cathodic protection. Finally, the design, construction and testing considerations are presented as an aid to others who wish to design a similar system.

Nelson, J.P.; Holm, W.K.

1983-09-01T23:59:59.000Z

399

Distribution Grounding of Underground Facilities  

Science Conference Proceedings (OSTI)

This report describes Phase I of a two-phase project to assess industry practices and standards for grounding and bonding of medium-voltage underground residential distribution (URD) and underground commercial distribution (UCD) circuits and worker safety in worksites with these systems.The report includes an overview of the issues and concerns associated with underground distribution systems safety and, in particular, worker safety in worksites. It identifies the industry and utility ...

2013-12-20T23:59:59.000Z

400

Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE)  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Electric Vehicle Electric Vehicle Supply Equipment (EVSE) Rebate - Indiana Michigan Power to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - Indiana Michigan Power on Facebook Tweet about Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - Indiana Michigan Power on Twitter Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - Indiana Michigan Power on Google Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - Indiana Michigan Power on Delicious Rank Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - Indiana Michigan Power on Digg Find More places to share Alternative Fuels Data Center: Electric

Note: This page contains sample records for the topic "ground support equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Property Tax Assessment for Renewable Energy Equipment | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Property Tax Assessment for Renewable Energy Equipment Property Tax Assessment for Renewable Energy Equipment Property Tax Assessment for Renewable Energy Equipment < Back Eligibility Utility Savings Category Bioenergy Water Buying & Making Electricity Solar Wind Program Info State Arizona Program Type Property Tax Incentive Rebate Amount Renewable-energy equipment assessed at 20% of its depreciated cost Provider Arizona Department of Revenue Renewable energy equipment owned by utilities and other entities operating in Arizona is assessed at 20% of its depreciated cost for the purpose of determining property tax. "Renewable energy equipment" is defined as "electric generation facilities, electric transmission, electric distribution, gas distribution or combination gas and electric transmission

402

Alternative Fuels Data Center: Highway Electric Vehicle Supply Equipment  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Highway Electric Highway Electric Vehicle Supply Equipment (EVSE) Installation Requirements to someone by E-mail Share Alternative Fuels Data Center: Highway Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Facebook Tweet about Alternative Fuels Data Center: Highway Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Twitter Bookmark Alternative Fuels Data Center: Highway Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Google Bookmark Alternative Fuels Data Center: Highway Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Delicious Rank Alternative Fuels Data Center: Highway Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Digg Find More places to share Alternative Fuels Data Center: Highway

403

Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) and  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Vehicle Vehicle Supply Equipment (EVSE) and Battery Exchange Station Regulations to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) and Battery Exchange Station Regulations on Facebook Tweet about Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) and Battery Exchange Station Regulations on Twitter Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) and Battery Exchange Station Regulations on Google Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) and Battery Exchange Station Regulations on Delicious Rank Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) and Battery Exchange Station Regulations on Digg Find More places to share Alternative Fuels Data Center: Electric

404

Floor Support | Stanford Synchrotron Radiation Lightsource  

NLE Websites -- All DOE Office Websites (Extended Search)

Floor Support Floor Support Service Responsible Person BLDG Extension (650) 926-XXXX Beam Status Duty Operator 120 926-2326 (BEAM) Duty Operator Cell Duty Operator 120 926-4040 Scheduling X-ray/VUV Macromolecular Crystallography Cathy Knotts Lisa Dunn 120 120 3191 2087 User Check-In/Badging Jackie Kerlegan 120 2079 User Financial Accounts Jackie Kerlegan 120 2079 Beam Lines/ VUV Bart Johnson 120 3858 Beam Lines/ X-ray Bart Johnson 120 3858 Beam Lines/ X-ray Mechanical Chuck Troxel, Jr. 120 2700 Beam Lines/ X-ray-VUV Electronics Alex Garachtchenko 120 3440 Beam Lines/ Macromolecular Crystallography Mike Soltis 277 3050 SMB XAS Beam Lines & Equipment Matthew Latimer Erik Nelson 274 274 4944 3938 MEIS XAS Beam Lines & Equipment Matthew Latimer

405

Chapter 10 - Property, Plant and Equipment  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7-18-2011 7-18-2011 Chapter 10-1 CHAPTER 10 PROPERTY, PLANT, AND EQUIPMENT 1. INTRODUCTION. a. Background/Authorities. This chapter describes financial controls over the acquisition, use, and retirement of property and provides guidelines for distinguishing between charges to capital accounts and charges to expense accounts consistent with the Statement of Federal Financial Accounting Standards (SFFAS). b. Applicability. The applicability of this chapter is specified in Chapter 1, "Accounting Overview." When in conflict with the provisions of this paragraph, power marketing administrations (PMAs) should observe the policies of the Federal Energy Regulatory Commission and other industry

406

Laboratory Equipment Donation Program - LEDP Widget Code  

Office of Scientific and Technical Information (OSTI)

Widget Inclusion Code Widget Inclusion Code Copy the code below and paste it to your website or blog: