Sample records for generation performance standard

  1. Standard Practice for Generating All-Day Thermal Performance Data for Solar Collectors

    E-Print Network [OSTI]

    American Society for Testing and Materials. Philadelphia

    1987-01-01T23:59:59.000Z

    1.1 This practice covers a means of generating all-day thermal performance data for flat-plate collectors, concentrating collectors, and tracking collectors. 1.2 The values stated in SI units are to be regarded as the standard. The values given in the parentheses are for information only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. U.S. Installation, Operation, and Performance Standards for Microturbi...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Installation, Operation, and Performance Standards for Microturbine Generator Sets, August 2000 U.S. Installation, Operation, and Performance Standards for Microturbine Generator...

  3. Distributed Generation Standard Contracts

    Broader source: Energy.gov [DOE]

    '''''Note: The second enrollment period for standard contracts in 2013 closed June 28. The third is scheduled to begin in September.'''''

  4. Interconnection Standards for Small Generators

    Broader source: Energy.gov [DOE]

    The Federal Energy Regulatory Commission (FERC) adopted "small generator" interconnection standards for distributed energy resources up to 20 megawatts (MW) in capacity in May 2005.* The FERC's...

  5. Environmental Public Health Performance Standards

    E-Print Network [OSTI]

    Environmental Public Health Performance Standards Environmental Health Program Self Agency: Total Environmental Health Program Budget: #12;Environmental Public Health Performance Standards (v. 2.0); Environmental Health Program Assessment Instrument, 1/7/2010 Page 2 Proportion

  6. Environmental Public Health Performance Standards

    E-Print Network [OSTI]

    Environmental Public Health Performance Standards (Version 2.0) Updated May 2014 National Center for Environmental Health Division of Emergency and Environmental Health Services #12;#12;Environmental Public Health Performance Standards (Version 2.0) Updated May 2014 #12;Environmental Public Health Performance Standards

  7. PV System Performance and Standards

    SciTech Connect (OSTI)

    Osterwald, C. R.

    2005-11-01T23:59:59.000Z

    This paper presents a brief overview of the status and accomplishments during fiscal year (FY) 2005 of the Photovoltaic (PV) System Performance and Standards Subtask, which is part of the PV Systems Engineering Project (a joint NREL-Sandia project).

  8. Collaborative Virtual Environment Standards: A Performance Evaluation

    E-Print Network [OSTI]

    Ottawa, University of

    for each standard varies from graphics and rendering to simulation and network communication. Standards categories: Rendering and Graphics and Communications Middleware. 2.1 Rendering and Graphics These standards1 Collaborative Virtual Environment Standards: A Performance Evaluation Jauvane C. de Oliveira

  9. Chapter 63 General Standards of Performance (Kentucky)

    Broader source: Energy.gov [DOE]

    Kentucky Administrative Regulation Chapter 63, entitled Air Quality: General Standards of Performance, is promulgated under the authority of the Division of Air Quality within the Energy and...

  10. IEC International Standards Under Development For Radiation-Generating Devices

    SciTech Connect (OSTI)

    Voytchev, M; Radev, R; Chiaro, P; Thomson, I; Dray, C; Li, J

    2007-12-06T23:59:59.000Z

    The International Electrotechnical Commission (IEC) is the leading and oldest global organization with over 100 years history of developing and publishing international standards for all electrical, electronic and related technologies, including radiation detection instrumentation. Subcommittee 45B 'Radiation Protection Instrumentation' of the IEC has recently started the development of two standards on radiation-generating devices. IEC 62463 'Radiation protection instrumentation--X-ray Systems for the Screening of Persons for Security and the Carrying of Illicit Items' is applicable to X-ray systems designed for screening people to detect if they are carrying objects such as weapons, explosives, chemical and biological agents and other concealed items that could be used for criminal purposes, e.g. terrorist use, drug smuggling, etc. IEC 62523 'Radiation protection instrumentation--Cargo/Vehicle radiographic inspection systems' applies to cargo/vehicle imaging inspection systems using accelerator produced X-ray or gamma radiation to obtain images of the screened objects (e.g. cargo containers, transport and passenger vehicles and railroad cars). The objective of both standards is to specify standard requirements and general characteristics and test procedures, as well as, radiation, electrical, environmental, mechanical, and safety requirements and to provide examples of acceptable methods to test these requirements. In particular the standards address the design requirements as they relate to the radiation protection of the people being screened, people who are in the vicinity of the equipment and the operators. The standard IEC 62463 does not deal with the performance requirements for the quality of the object detection. Compliance with the standards requirements will provide the manufacturers with internationally acceptable specifications and the device users with assurance of the rigorous quality and accuracy of the measurements in relation to the radiological safety of the equipment. The main characteristics of IEC 62463 and IEC 62523 standards are presented and as well as the IEC methodology of standard development and approval.

  11. Fact Sheet: Codes and Standards for Energy Storage System Performance...

    Energy Savers [EERE]

    Codes and Standards for Energy Storage System Performance and Safety (June 2014) Fact Sheet: Codes and Standards for Energy Storage System Performance and Safety (June 2014) The...

  12. Chapter 32 Standards Applicable to Generators of Hazardous Waste (Kentucky)

    Broader source: Energy.gov [DOE]

    This administrative regulation establishes procedures to establish the applicable general provisions for generators of hazardous waste. It also establishes recordkeeping and reporting standards....

  13. CALIFORNIA'S NEXT GENERATION OF LOAD MANAGEMENT STANDARDS

    E-Print Network [OSTI]

    upon privately owned rights. This report has not been approved or disapproved by the California Energy eliminate the need for new peaking generation capacity and associated transmission and distribution capacity" authority as a way to achieve higher levels of cost-effective DR. The California Energy Action Plan II (EAP

  14. CALIFORNIA'S NEXT GENERATION OF LOAD MANAGEMENT STANDARDS

    E-Print Network [OSTI]

    upon privately owned rights. This report has not been approved or disapproved by the California Energy the need for new peaking generation capacity and associated transmission and distribution capacity's "load management" authority as a way to achieve higher levels of costeffective demand response

  15. Design and Performance Aspects of Steam Generators

    E-Print Network [OSTI]

    Ganapathy, V.

    generators based on standard, pre-packaged designs. A "standard" boiler has several limitations such as pre-determined furnace dimensions, tube length, surface area, tube spacings etc, which may or may not be the optimum choice for a given steam demand...

  16. Issues in the Next Generation of Dependability Standards Existing IEEE software reliability standards do not

    E-Print Network [OSTI]

    Lyu, Michael R.

    systems. The extant software reliability standards and practices, using IEEE 982 [1] and AIAA R013 [2Issues in the Next Generation of Dependability Standards Abstract Existing IEEE software, these standards do not consider both hardware and software reliability nor do they include availability

  17. High Performance Building Standards in New State Construction

    Broader source: Energy.gov [DOE]

    In January 2008, New Jersey enacted legislation mandating the use of high performance green building standards in new state construction. The standard requires that new buildings larger than 15...

  18. Managerial Performance Standards COLLEGE NAME TITLE DATE

    E-Print Network [OSTI]

    Qiu, Weigang

    disruption and ensure safety of all persons and property; makes extra effort to provide assistance that may be performed by employees in managerial titles, but no one manager is likely to perform all leadership roles in College committees, programs, activities, project implementation/evaluation, etc. beyond

  19. Performance characterization of the NASA standard detonator

    SciTech Connect (OSTI)

    Tarbell, W.W. [Sandia National Labs., Albuquerque, NM (United States); Burke, T.L.; Solomon, S.E. [Component Engineering, USBI, Huntsville, AL (United States)

    1995-05-01T23:59:59.000Z

    The NASA Standard Detonator (NSD) is employed in support of a number of current applications, including the Space Shuttle. This effort was directed towards providing test results to characterize the output of this device for its use in a safe and arm device. As part of the investigation, flash X-ray was used to provide stop-motion photographs of the flying metal plate that is created by initiation of the detonator. This provided researchers with a better understanding of the shape and character of the high-velocity disk as it propagated across the gap between the detonator and next assembly. The second portion of the study used a velocity interferometer to evaluate the acceleration and velocity histories of the flying plate, providing a quantified assessment of the detonator`s ability to initiate the explosive in the next explosive.

  20. Construction Standards and Costs UC Irvine new construction pursues performance goals and applies quality standards that

    E-Print Network [OSTI]

    Rose, Michael R.

    Construction Standards and Costs UC Irvine new construction pursues performance goals and applies quality standards that affect the costs of capital projects. Periodic re-examination of these goals and standards is warranted. Construction costs are not "high" or "low" in the abstract, but rather in relation

  1. Voting Systems Performance and Test Standards: An Overview

    E-Print Network [OSTI]

    Rivest, Ronald L.

    and implement performance and test Standards for electronic voting equipment is over 25 years old. However to submit their equipment to an Independent Test Authority (ITA) for evaluation against the Standards testing and qualification process. In addition, many systems have subsequently been certified at the state

  2. Design and Performance Aspects of Steam Generators 

    E-Print Network [OSTI]

    Ganapathy, V.

    1994-01-01T23:59:59.000Z

    -DESIGNING The concept of custom designing packaged steam generators is not new. Those familiar with heat recovery applications know that efficency and gas pressure drop are critical factors from boiler performance viewpoint and efforts should be made... gas pressure drop in a 100,000 lb/h boiler is equivalent to 15-18 kw of additional power or $ 7500 per year electricity bill, not to mention the larger fan size. Due to higher gas flow,the boiler efficency will also be affected. The exit gas...

  3. Development of standardized air-blown coal gasifier/gas turbine concepts for future electric power systems, Volume 4. Appendix C: Design and performance of standardized fixed bed air-blown gasifier IGCC systems for future electric power generation: Final report

    SciTech Connect (OSTI)

    Not Available

    1991-02-01T23:59:59.000Z

    This appendix is a compilation of work done to predict overall cycle performance from gasifier to generator terminals. A spreadsheet has been generated for each case to show flows within a cycle. The spreadsheet shows gaseous or solid composition of flow, temperature of flow, quantity of flow, and heat heat content of flow. Prediction of steam and gas turbine performance was obtained by the computer program GTPro. Outputs of all runs for each combined cycle reviewed has been added to this appendix. A process schematic displaying all flows predicted through GTPro and the spreadsheet is also added to this appendix. The numbered bubbles on the schematic correspond to columns on the top headings of the spreadsheet.

  4. TRENDS IN POWER PERFORMANCE MEASUREMENT STANDARDS Troels F. Pedersen

    E-Print Network [OSTI]

    Turbines Meorology and Wind Energy Department RISØ National Laboratory DK-4000 Roskilde Denmark 1 a wind energy project is planned, this uncertainty of the measured power performance of a wind turbine, expressed as a standard deviation, should be taken into account. When a wind energy project have been

  5. Electronic Vehicle Identification: Industry Standards, Performance, and Privacy Issues

    E-Print Network [OSTI]

    Texas at Austin, University of

    0-5217-P2 Electronic Vehicle Identification: Industry Standards, Performance, and Privacy Issues Authors: Dr. Khali Persad Dr. C. Michael Walton Shahriyar Hussain Project 0-5217: Vehicle/License Plate. Privacy concerns regarding collection and use of data on vehicle movements are examined in the context

  6. Voting Systems Performance and Test Standards: An Overview

    E-Print Network [OSTI]

    and implement performance and test Standards for electronic voting equipment is over 25 years old. However (see attachment).2 NASED has established a process for vendors to submit their equipment or components of voting systems have gone through the NASED testing and qualification process. In addition, many

  7. Performance and Emissions of a Second Generation Biofuel -DME

    E-Print Network [OSTI]

    Minnesota, University of

    , Isuzu and Renault are advocating DME as a second generation Diesel fuel and are testing prototypePerformance and Emissions of a Second Generation Biofuel - DME D. Kittelson1, W. Watts1, D. Bennett, 2010 #12;Performance and Emissions of a Second Generation Biofuel: DME · We started working on a three

  8. Commentary & Feedback on Draft I of the Next Generation Science Standards

    E-Print Network [OSTI]

    Lynch, John M.

    Commentary & Feedback on Draft I of the Next Generation Science Standards June 20, 2012 By Paul R. Alignment with the Common Core Mathematics Standards........................17 IV. Recommended Improvements for a new set of "next generation" standards (NGSS) for primary- secondary school science in the United

  9. Reference-area performance standards for Puget Sound

    SciTech Connect (OSTI)

    Not Available

    1991-09-01T23:59:59.000Z

    Chemical and biological conditions in the sediments at sites in three areas of Puget Sound were analyzed as part of the study. Analysis of sediments from Samish Bay, Holmes Harbor, and Carr Inlet included chemical concentrations, total organic carbon, acid-volatile sulfides, total solids, grain size distribution, and sediment toxicity as measured by amphipod mortality, bivalve larvae mortality and abnormality, echinoderm embryo mortality and abnormality, juvenile polychaete mortality and biomass, and saline Microtox bacterial luminescence bioassays. The performance standards developed for Puget Sound sediment reference sites will provide a consistent basis for comparison and use of sediment data collected by various programs. Based on the performance standards developed, the report found specific stations in Carr Inlet, Holmes Harbor, and Samish Bay to be suitable as sediment reference areas.

  10. Impact of Power Generation Uncertainty on Power System Static Performance

    E-Print Network [OSTI]

    Liberzon, Daniel

    in load and generation are modeled as random variables and the output of the power flow computationImpact of Power Generation Uncertainty on Power System Static Performance Yu Christine Chen, Xichen--The rapid growth in renewable energy resources such as wind and solar generation introduces significant

  11. Forensic DNA Standards for Next Generation Sequencing Platforms ( 7th Annual SFAF Meeting, 2012)

    ScienceCinema (OSTI)

    Vallone, Peter [NIST

    2013-03-22T23:59:59.000Z

    Peter Vallone on "Forensic DNA Standards for Next Generation Sequencing Platforms" at the 2012 Sequencing, Finishing, Analysis in the Future Meeting held June 5-7, 2012 in Santa Fe, New Mexico.

  12. Forensic DNA Standards for Next Generation Sequencing Platforms ( 7th Annual SFAF Meeting, 2012)

    SciTech Connect (OSTI)

    Vallone, Peter [NIST] [NIST

    2012-06-01T23:59:59.000Z

    Peter Vallone on "Forensic DNA Standards for Next Generation Sequencing Platforms" at the 2012 Sequencing, Finishing, Analysis in the Future Meeting held June 5-7, 2012 in Santa Fe, New Mexico.

  13. Government-led performance standard and high-tech innovation in China : a case study of Zhongguancun high-tech development zone

    E-Print Network [OSTI]

    Chen, Yang, M.C.P. Massachusetts Institute of Technology

    2011-01-01T23:59:59.000Z

    The object of the thesis is to gain an understanding of the role that Chinese government has played in promoting high-tech industries through performance standards and the output the policy generates. As a latecomer in the ...

  14. Using Mathematics Curriculum Based Measurement as an Indicator of Student Performance on State Standards

    E-Print Network [OSTI]

    Hall, Linda D.

    2010-07-14T23:59:59.000Z

    that reported to be aligned to national curriculum standards in order to predict student performance on state standards-based mathematics curriculum, identify students at-risk of failure, and plan instruction. Evidence was gathered on the System to Enhance...

  15. Automated Formula Generation and Performance Learning for the FFT

    E-Print Network [OSTI]

    Automated Formula Generation and Performance Learning for the FFT Bryan Singer Manuela Veloso equivalent formulas. When these formulas are implemented in actual code, they often have very di erent running times. Thus, an important problem is nding a formula that implements the signal processing

  16. Automated Formula Generation and Performance Learning for the FFT

    E-Print Network [OSTI]

    Automated Formula Generation and Performance Learning for the FFT Bryan Singer Manuela Veloso equivalent formulas. When these formulas are implemented in actual code, they often have very different running times. Thus, an important problem is finding a formula that implements the signal processing

  17. Systems engineering approach towards performance monitoring of emergency diesel generator

    SciTech Connect (OSTI)

    Ramli, Nurhayati, E-mail: nurhayati14@gmail.com; Yong-kwan, Lee, E-mail: nurhayati14@gmail.com [KEPCO International Nuclear Graduate School, 1456-1 Shinam-ri, Ulsan 689-882 (Korea, Republic of)

    2014-02-12T23:59:59.000Z

    Systems engineering is an interdisciplinary approach and means to enable the realization of successful systems. In this study, systems engineering approach towards the performance monitoring of Emergency Diesel Generator (EDG) is presented. Performance monitoring is part and parcel of predictive maintenance where the systems and components conditions can be detected before they result into failures. In an effort to identify the proposal for addressing performance monitoring, the EDG boundary has been defined. Based on the Probabilistic Safety Analysis (PSA) results and industry operating experiences, the most critical component is identified. This paper proposed a systems engineering concept development framework towards EDG performance monitoring. The expected output of this study is that the EDG reliability can be improved by the performance monitoring alternatives through the systems engineering concept development effort.

  18. IEEE Standard for qualification of Class 1E lead storage batteries for nuclear power generating stations

    SciTech Connect (OSTI)

    Not Available

    1980-01-01T23:59:59.000Z

    This document describes qualification methods for Class 1E lead storage batteries and racks to be used in nuclear power generating stations outside of primary containment. Qualification required in ANSI/IEEE Std 279-1979 and IEEE Std 308-1978, can be demonstrated by using the procedures provided in this Standard in accordance with IEEE Std 323-1974. Battery sizing, maintenance, capacity testing, installation, charging equipment and consideration of other types batteries are beyond the scope of this Standard.

  19. Cost and Performance Assumptions for Modeling Electricity Generation Technologies

    SciTech Connect (OSTI)

    Tidball, R.; Bluestein, J.; Rodriguez, N.; Knoke, S.

    2010-11-01T23:59:59.000Z

    The goal of this project was to compare and contrast utility scale power plant characteristics used in data sets that support energy market models. Characteristics include both technology cost and technology performance projections to the year 2050. Cost parameters include installed capital costs and operation and maintenance (O&M) costs. Performance parameters include plant size, heat rate, capacity factor or availability factor, and plant lifetime. Conventional, renewable, and emerging electricity generating technologies were considered. Six data sets, each associated with a different model, were selected. Two of the data sets represent modeled results, not direct model inputs. These two data sets include cost and performance improvements that result from increased deployment as well as resulting capacity factors estimated from particular model runs; other data sets represent model input data. For the technologies contained in each data set, the levelized cost of energy (LCOE) was also evaluated, according to published cost, performance, and fuel assumptions.

  20. Review of Consensus Standard Spectra for Flat Plate and Concentrating Photovoltaic Performance

    SciTech Connect (OSTI)

    Myers, D.

    2011-09-01T23:59:59.000Z

    Consensus standard reference terrestrial solar spectra are used to establish nameplate ratings for photovoltaic device performance at standard reporting conditions. This report describes reference solar spectra developed in the United States and international consensus standards community which are widely accepted as of this writing (June 2011).

  1. Performance of various computers using standard linear equations

    SciTech Connect (OSTI)

    Dongarra, J. (Univ. of Tennessee, TN (US))

    1989-01-01T23:59:59.000Z

    This report compares the performance of different computer systems in solving dense systems of linear equations. The comparison involves approximately one hundred computers, ranging from a CRAY Y-MP to scientific workstations such as the Apollo and Sun to IBM PCs.

  2. Coal-fired high performance power generating system. Final report

    SciTech Connect (OSTI)

    NONE

    1995-08-31T23:59:59.000Z

    As a result of the investigations carried out during Phase 1 of the Engineering Development of Coal-Fired High-Performance Power Generation Systems (Combustion 2000), the UTRC-led Combustion 2000 Team is recommending the development of an advanced high performance power generation system (HIPPS) whose high efficiency and minimal pollutant emissions will enable the US to use its abundant coal resources to satisfy current and future demand for electric power. The high efficiency of the power plant, which is the key to minimizing the environmental impact of coal, can only be achieved using a modern gas turbine system. Minimization of emissions can be achieved by combustor design, and advanced air pollution control devices. The commercial plant design described herein is a combined cycle using either a frame-type gas turbine or an intercooled aeroderivative with clean air as the working fluid. The air is heated by a coal-fired high temperature advanced furnace (HITAF). The best performance from the cycle is achieved by using a modern aeroderivative gas turbine, such as the intercooled FT4000. A simplified schematic is shown. In the UTRC HIPPS, the conversion efficiency for the heavy frame gas turbine version will be 47.4% (HHV) compared to the approximately 35% that is achieved in conventional coal-fired plants. This cycle is based on a gas turbine operating at turbine inlet temperatures approaching 2,500 F. Using an aeroderivative type gas turbine, efficiencies of over 49% could be realized in advanced cycle configuration (Humid Air Turbine, or HAT). Performance of these power plants is given in a table.

  3. Building Energy Efficiency Standards Approved Default Cool Roof Performance Values for

    E-Print Network [OSTI]

    Building Energy Efficiency Standards Approved Default Cool Roof Performance Values for Low-Sloped Roofs That Use Aggregate As the Surface Layer Aggregate used as the surface layer of low-sloped roofs shall have the default cool roof properties

  4. Analysis of Minimum Efficiency Performance Standards for Residential General Service Lighting in Chile

    SciTech Connect (OSTI)

    Letschert, Virginie E.; McNeil, Michael A.; Leiva Ibanez, Francisco Humberto; Ruiz, Ana Maria; Pavon, Mariana; Hall, Stephen

    2011-06-01T23:59:59.000Z

    Minimum Efficiency Performance Standards (MEPS) have been chosen as part of Chile's national energy efficiency action plan. As a first MEPS, the Ministry of Energy has decided to focus on a regulation for lighting that would ban the sale of inefficient bulbs, effectively phasing out the use of incandescent lamps. Following major economies such as the US (EISA, 2007) , the EU (Ecodesign, 2009) and Australia (AS/NZS, 2008) who planned a phase out based on minimum efficacy requirements, the Ministry of Energy has undertaken the impact analysis of a MEPS on the residential lighting sector. Fundacion Chile (FC) and Lawrence Berkeley National Laboratory (LBNL) collaborated with the Ministry of Energy and the National Energy Efficiency Program (Programa Pais de Eficiencia Energetica, or PPEE) in order to produce a techno-economic analysis of this future policy measure. LBNL has developed for CLASP (CLASP, 2007) a spreadsheet tool called the Policy Analysis Modeling System (PAMS) that allows for evaluation of costs and benefits at the consumer level but also a wide range of impacts at the national level, such as energy savings, net present value of savings, greenhouse gas (CO2) emission reductions and avoided capacity generation due to a specific policy. Because historically Chile has followed European schemes in energy efficiency programs (test procedures, labelling program definitions), we take the Ecodesign commission regulation No 244/2009 as a starting point when defining our phase out program, which means a tiered phase out based on minimum efficacy per lumen category. The following data were collected in order to perform the techno-economic analysis: (1) Retail prices, efficiency and wattage category in the current market, (2) Usage data (hours of lamp use per day), and (3) Stock data, penetration of efficient lamps in the market. Using these data, PAMS calculates the costs and benefits of efficiency standards from two distinct but related perspectives: (1) The Life-Cycle Cost (LCC) calculation examines costs and benefits from the perspective of the individual household; and (2) The National Perspective projects the total national costs and benefits including both financial benefits, and energy savings and environmental benefits. The national perspective calculations are called the National Energy Savings (NES) and the Net Present Value (NPV) calculations. PAMS also calculate total emission mitigation and avoided generation capacity. This paper describes the data and methodology used in PAMS and presents the results of the proposed phase out of incandescent bulbs in Chile.

  5. Improving Dynamic Load and Generator Response PerformanceTools

    SciTech Connect (OSTI)

    Lesieutre, Bernard C.

    2005-11-01T23:59:59.000Z

    This report is a scoping study to examine research opportunities to improve the accuracy of the system dynamic load and generator models, data and performance assessment tools used by CAISO operations engineers and planning engineers, as well as those used by their counterparts at the California utilities, to establish safe operating margins. Model-based simulations are commonly used to assess the impact of credible contingencies in order to determine system operating limits (path ratings, etc.) to ensure compliance with NERC and WECC reliability requirements. Improved models and a better understanding of the impact of uncertainties in these models will increase the reliability of grid operations by allowing operators to more accurately study system voltage problems and the dynamic stability response of the system to disturbances.

  6. Cost and performance data on diesel engine generators and pumps

    SciTech Connect (OSTI)

    Kenna, J.

    1987-05-01T23:59:59.000Z

    This report summarizes performance data and costs of operation and maintenance obtained from seven diesel engines operating under field conditions in Kenya. Four of the engines were diesel water pumps and three were diesel generators. Short-term tests (2-hour) were conducted on-site to determine engine efficiency as a function of time after start-up. After the short-term tests, the engines were monitored for a 3-month period to determine use pattern and fuel consumption. In addition, the owners (or operators) completed a questionnaire which documented their perception of reliability and operation and maintenance costs. The short-term tests showed that the diesel efficiencies were primarily dependent on the load factor and time from start-up to shut-down. The measured efficiencies were significantly reduced when the diesels were run for either short periods (less than 90 minutes for the generators and 30 minutes for the pumps) or with loads less than their rated output. The data collected during the 3-month monitoring period revealed relatively low efficiencies because of low load factors and short run periods. This type of use pattern is typical for diesels in Kenya. Operation and maintenance costs varied from .20 to .95 $/kWh for the generators, and from .13 to .74 $/m/sup 3/ of water for the pumps, depending primarily on the efficiency and the cost of labor for an operator and repairs. The owners' perception of the operation and maintenance costs was usually significantly less than the measured costs. 15 figs., 5 tabs.

  7. Performance of solar electric generating systems on the utility grid

    SciTech Connect (OSTI)

    Roland, J.R.

    1986-01-01T23:59:59.000Z

    The first year of performance of the Solar Electric Generating System I (SEGS I), which has been operating on the Southern California Edison (SCE) grid since December 1984 is discussed. The solar field, comprised of 71,680 m/sup 2/ of Luz parabolic trough line-focus solar collectors, supplies thermal energy at approx. 585/sup 0/F to the thermal storage tank. This energy is then used to generate saturated steam at 550 psia and 477/sup 0/F which passes through an independent natural gas-fired superheater and is brought to 780/sup 0/F superheat. The solar collector assembly (SCA) is the primary building block of this modular system. A single SCA consists of a row of eight parabolic trough collectors, a single drive motor, and a local microprocessor control unit. The basic components of the parabolic trough collector are a mirrored glass reflector, a unique and highly efficient heat collection element, and a tracking/positioning system. The heat collector element contains a stainless steel absorber tube coated with black chrome selective surface and is contained within an evacuated cylindrical glass envelope. The plant has reached the design capacity of 14.7 MW and, on a continuous basis, provides approx. 13.8 MW of net power during the utility's on-peak periods (nominally 12:00 noon to 6:00 p.m. during the summer weekdays and 5:00 p.m. to 10:00 p.m. during the winter weekdays).

  8. Development of an ASTM standard guide on performing vulnerability assessments for nuclear facilities

    SciTech Connect (OSTI)

    Wilkey, D.D.

    1995-09-01T23:59:59.000Z

    This paper describes an effort undertaken by subcommittee C26.12 (Safeguards) of the American Society for Testing and Materials (ASTM) to develop a standard guide for performing vulnerability assessments (VAs). VAs are performed to determine the effectiveness of safeguards and security systems for both domestic and international nuclear facilities. These assessments address a range of threats, including theft of nuclear material and sabotage, and use an array of methods. The approach to performing and documenting VAs is varied and is largely dependent upon the tools used to perform them. This diversity can lead to tools being misused, making validation of VAs more difficult. The development of a standard guide for performing VAs would, if generally accepted, alleviate these concerns. ASTM provides a forum for developing guides that includes a high level of peer review to assure that the result is acceptable to all potential users. Additionally, the ASTM is widely recognized for setting standards, and endorsement by the Society may increase the likelihood of acceptance by the nuclear community. The goal of this work is to develop a guide that is independent of the tools being used to perform the VA and applicable to the spectrum of threats described above.

  9. Environmental Public Health Performance Standards Environmental Health Program Self-assessment Instrument (Version 2)

    E-Print Network [OSTI]

    Environmental Public Health Performance Standards Environmental Health Program Self-assessment Assessment Instrument, 1/7/2010 Page 3 Essential Service #1: Monitor environmental and health status health assessment been completed? 1.1B Is the community environmental health assessment updated at least

  10. Standard Test Method for Electrical Performance of Photovoltaic Cells Using Reference Cells Under Simulated Sunlight

    E-Print Network [OSTI]

    American Society for Testing and Materials. Philadelphia

    2009-01-01T23:59:59.000Z

    1.1 This test method covers the determination of the electrical performance of a photovoltaic cell under simulated sunlight by means of a calibrated reference cell procedure. 1.2 Electrical performance measurements are reported with respect to a select set of standard reporting conditions (SRC) (see Table 1) or to user-specified conditions. 1.2.1 The SRC or user-specified conditions include the cell temperature, the total irradiance, and the reference spectral irradiance distribution. 1.3 This test method is applicable only to photovoltaic cells with a linear response over the range of interest. 1.4 The cell parameters determined by this test method apply only at the time of test, and imply no past or future performance level. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this s...

  11. Performance of hybrid quad generation system consisting of solid oxide fuel cell system and

    E-Print Network [OSTI]

    Liso, Vincenzo

    Performance of hybrid quad generation system consisting of solid oxide fuel cell system. Keywords: Energy system modeling, Solid oxide fuel cell, Absorption heat pump. 1. Introduction 1

  12. A Stable Whole Building Performance Method for Standard 90.1

    SciTech Connect (OSTI)

    Rosenberg, Michael I.; Eley, Charles

    2013-05-01T23:59:59.000Z

    Wouldn’t it be great if a single energy model could be used to demonstrate minimum code compliance, green code compliance, establish a Leadership in Energy and Environmental Design (LEED) rating, and determine eligibility for federal tax and utility incentives? Even better, what if the basic rules for creating those models did not change every few years? This paper descibes a recently proposed addendum to ASHRAE/ANSI/IES Standard 90.1 aims to meet those goals. Addendum BM establishes the Performance Rating Method found in Appendix G of Standard 90.1 as a new method of compliance while maintaining its traditional use in gauging the efficiency of beyond code buildings. Furthermore, Addendum BM sets a common baseline building that does not change with each update to the standard.

  13. High Performance Code Generation for Stencil Computation on Heterogeneous Multi-device

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    .namyst@inria.fr Abstract--Heterogeneous architectures have been widely used in the domain of high performance computing, Multi- device, Code generation, Heterogeneous architectures I. INTRODUCTION High performance computing

  14. Integrated design : a generative multi-performative design approach

    E-Print Network [OSTI]

    Fasoulaki, Eleftheria

    2008-01-01T23:59:59.000Z

    There are building systems, called "modularized", in which the component systems (for structure, lighting, etc) can be analyzed and synthesized independently since their performance and design do not interact or affect one ...

  15. Impact of Soiling and Pollution on PV Generation Performance

    Broader source: Energy.gov [DOE]

    This 5-page technical letter addresses air pollution effects on PV performance by quantifying, based on a literature search, the average annual loss due to soiling, the impact of cleaning, and a recommended cleaning schedule.

  16. Unlocking the Standard Model. IV. N=1 AND 2 generations of quarks : spectrum and mixing

    E-Print Network [OSTI]

    Bruno Machet

    2013-09-30T23:59:59.000Z

    Using a one-to-one correspondence between its complex Higgs doublet and very specific quadruplets of bilinear quark operators, the Glashow-Salam-Weinberg model for 2 generations is extended, without adding any extra fermion, to 8 composite Higgs multiplets. 8 is the minimal number required to suitably account, simultaneously, for the pseudoscalar mesons that can be built with 4 quarks and for the mass of the W gauge bosons. Their masses being used as input, together with elementary low energy considerations for the pions, we calculate all other parameters, masses and couplings. We focus in this work on the spectrum of the 8 Higgs bosons, and on the two u-c and d-s mixing angles, showing that this is very fine-tuned physics. We show in particular that the u-c mixing angle cannot be safely tuned to 0. Symmetries are investigated in detail. We leave the study of couplings and of their content of non-standard physics to a forthcoming work.

  17. Potential improvements in SiGe radioisotope thermoelectric generator performance

    SciTech Connect (OSTI)

    Mowery, A.L. [4 Myrtle Bank Lane, Hilton Head Island, South Carolina, 29926-2650 (United States)

    1999-01-01T23:59:59.000Z

    In accordance with NASA{close_quote}s slogan: {open_quotes}Better, Cheaper, Faster,{close_quotes} this paper will address potential improvements to SiGe RTG technology to make them Better. RTGs are doubtless cheaper than {open_quotes}paper designs{close_quotes} which are better and cheaper until development, performance and safety test costs are considered. RTGs have the advantage of being fully developed and tested in the rigors of space for over twenty years. Further, unless a new system can be accelerated tested, as were the RTGs, they cannot be deployed reliably unless a number of systems have succeeded for test periods exceeding the mission lifetime. Two potential developments are discussed that can improve the basic RTG performance by 10 to 40{sup +}{percent} depending on the mission profile. These improvements could be demonstrated in years. Accelerated testing could also be performed in this period to preserve existing RTG reliability. Data from a qualification tested RTG will be displayed, while not definitive, to support the conclusions. Finally, it is anticipated that other investigators will be encouraged to suggest further modifications to the basic RTG design to improve its performance. {copyright} {ital 1999 American Institute of Physics.}

  18. In Vitro and In Vivo Comparison of Optics and Performance of a Distal Sensor Ureteroscope Versus a Standard Fiberoptic Ureteroscope

    E-Print Network [OSTI]

    2013-01-01T23:59:59.000Z

    characteristics and optics of the X C with a stan- dardand In Vivo Comparison of Optics and Performance of a Distalperformance characteristics and optics of a new generation

  19. High Performance Fuel Desing for Next Generation Pressurized Water Reactors

    SciTech Connect (OSTI)

    Mujid S. Kazimi; Pavel Hejzlar

    2006-01-31T23:59:59.000Z

    The use of internally and externally cooled annular fule rods for high power density Pressurized Water Reactors is assessed. The assessment included steady state and transient thermal conditions, neutronic and fuel management requirements, mechanical vibration issues, fuel performance issues, fuel fabrication methods and econmic assessment. The investigation was donducted by a team from MIT, Westinghouse, Gamma Engineering, Framatome ANP, and AECL. The analyses led to the conclusion that raising the power density by 50% may be possible with this advanced fuel. Even at the 150% power level, the fuel temperature would be a few hundred degrees lower than the current fuel temperatre. Significant economic and safety advantages can be obtained by using this fuel in new reactors. Switching to this type of fuel for existing reactors would yield safety advantages, but the economic return is dependent on the duration of plant shutdown to accommodate higher power production. The main feasiblity issue for the high power performance appears to be the potential for uneven splitting of heat flux between the inner and outer fuel surfaces due to premature closure of the outer fuel-cladding gap. This could be overcome by using a very narrow gap for the inner fuel surface and/or the spraying of a crushable zirconium oxide film at the fuel pellet outer surface. An alternative fuel manufacturing approach using vobropacking was also investigated but appears to yield lower than desirable fuel density.

  20. Analysis of Minimum Efficiency Performance Standards for Residential General Service Lighting in Chile

    E-Print Network [OSTI]

    Letschert, Virginie E.

    2012-01-01T23:59:59.000Z

    into account the electricity generation fuel mix, and lossesaccording to typical electricity generation fuel mix. Carbon

  1. Interconnection Standards

    Broader source: Energy.gov [DOE]

    The North Carolina Utilities Commission (NCUC) adopted comprehensive interconnection standards for distributed generation in June 2008. The NCUC standards, which are similar to the Federal Energy...

  2. Interconnection Standards

    Broader source: Energy.gov [DOE]

    The Michigan Public Service Commission (PSC) first adopted interconnection standards for distributed generation (DG) in September 2003. The original standards provided for 5 levels of...

  3. Quantitative performance-based evaluation of a procedure for flexible design concept generation

    E-Print Network [OSTI]

    Cardin, Michel-Alexandre, 1979-

    2011-01-01T23:59:59.000Z

    This thesis presents an experimental methodology for objective and quantitative design procedure evaluation based on anticipated lifecycle performance of design concepts, and a procedure for flexible design concept generation. ...

  4. An Experimental Methodology to Evaluate Concept Generation Procedures Based on Quantitative Lifecycle Performance

    E-Print Network [OSTI]

    Cardin, Michel-Alexandre

    This study presents an experimental methodology to measure how concept generation procedures can affect the anticipated lifecycle performance of engineering systems design concepts. The methodology is based on objective ...

  5. Field Test Protocol: Standard Internal Load Generation in Unoccupied Test Homes

    SciTech Connect (OSTI)

    Fang, X.; Christensen, D.; Barker, G.; Hancock, E.

    2011-06-01T23:59:59.000Z

    This document describes a simple and general way to generate House Simulation Protocol (HSP)-consistent internal sensible and latent loads in unoccupied homes. It is newly updated based on recent experience, and provides instructions on how to calculate and set up the operational profiles in unoccupied homes. The document is split into two sections: how to calculate the internal load magnitude and schedule, and then what tools and methods should be used to generate those internal loads to achieve research goals.

  6. New source performance standards for industrial boilers. Volume 2. Review of industry operating practices

    SciTech Connect (OSTI)

    Bryan, R.J.; Weisenberg, I.J.; Wilson, K.

    1980-09-01T23:59:59.000Z

    The applicability is evaluated of several possible versions of a revised New Source Performance Standards (NSPS) for industrial boilers to boilers that are operated according to typical industry practices. A survey of operating practices is presented, and it is concluded that an NSPS that includes too high a percent removal requirement for SO/sub 2/ (90%) might be excessively costly and cause operating problems for the industrial operator. More field evaluations of low excess air and low Btu gasification are required to validate these techniques for pollution control under industrial boiler operating conditions. The cost of two small boilers with no SO/sub 2/ controls was less than one large boiler of twice the capacity with SO/sub 2/ controls. The annual cost of operating and maintaining the control system accounted for the difference.

  7. Effects of Modes of Cockpit Automation on Pilot Performance and Workload in a Next Generation

    E-Print Network [OSTI]

    Kaber, David B.

    Effects of Modes of Cockpit Automation on Pilot Performance and Workload in a Next Generation of advanced cockpit automation for flight planning on pilot performance and workload under a futuristic arrivals to an airport using three modes of automation (MOAs), including a control-display unit (CDU

  8. Evaluating the Energy Performance of the First Generation of LEED-Certified Commercial Buildings

    E-Print Network [OSTI]

    Evaluating the Energy Performance of the First Generation of LEED-Certified Commercial Buildings ABSTRACT Over three hundred buildings have been certified under the Leadership in Energy and Environmental the modeled and actual energy performance of a sample of 21 of these buildings that certified under LEED

  9. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation

    SciTech Connect (OSTI)

    NONE

    1997-03-01T23:59:59.000Z

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U.S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This manual covers an array of modules written for the SCALE package, consisting of drivers, system libraries, cross section and materials properties libraries, input/output routines, storage modules, and help files.

  10. Permissible loadings of generators and large motors. Facilities instructions, standards, and techniques. Volume 1-4

    SciTech Connect (OSTI)

    Watson, H.

    1991-03-01T23:59:59.000Z

    This volume is intended to fill the need for practical information concerning the temperature and mechanical and electrical overload limits of rotating electric equipment such as generators and large motors. Rotating electrical equipment cannot be overloaded on the same basis as transformers and is not as able to stand short-time overloads.

  11. Standards Pave the Way for Next Generation Workplace Charging Technology Opportunities/Decisions

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOriginEducationVideo »UsageSecretaryVideosSpring O&M UsersEnergy Standards Pave the Way

  12. Heisenberg versus standard scaling in quantum metrology with Markov generated states and monitored environment

    E-Print Network [OSTI]

    Catalin Catana; Madalin Guta

    2014-07-04T23:59:59.000Z

    Finding optimal and noise robust probe states is a key problem in quantum metrology. In this paper we propose Markov dynamics as a possible mechanism for generating such states, and show how the Heisenberg scaling emerges for systems with multiple `dynamical phases' (stationary states), and noiseless channels. We model noisy channels by coupling the Markov output to `environment' ancillas, and consider the scenario where the environment is monitored to increase the quantum Fisher information of the output. In this setup we find that the survival of the Heisenberg limit depends on whether the environment receives `which phase' information about the memory system.

  13. Unlocking the Standard Model. IV. N=2 generations of quarks : spectrum and mixing

    E-Print Network [OSTI]

    Machet, Bruno

    2013-01-01T23:59:59.000Z

    The Glashow-Salam-Weinberg model for 2 generations of quarks is extended to 8 composite Higgs multiplets, with no adjunction of extra fermions. It is the minimal number of Higgs doublets required to suitably account, simultaneously, for the spectrum of pseudoscalar mesons that can be built with 4 quarks and for the mass of the W gauge bosons. These masses being used as input, together with elementary low energy considerations for the pions, we calculate all other parameters, masses and couplings. We focus in this work on the spectrum of the 8 Higgs bosons (which all potentially contribute to the W and quark masses), and on the mixing (Cabibbo) angle, leaving the study of couplings to a subsequent work. The Higgs bosons fall into one triplet, two doublets and one singlet. In the triplet stand three states with masses \\sqrt{2} x that of heaviest pseudoscalar meson D_s, which, for 2 generations, pushes them up to 2.80 GeV. The 2 components of the first doublet have masses close to 1.25 GeV. The singlet has a mas...

  14. Orange County- Wind Permitting Standards

    Broader source: Energy.gov [DOE]

    In December 2010, the County of Orange Board of Supervisors adopted small wind performance and development standards (Ord. No. 10-020) in order to promote distributed generation systems in non...

  15. Laboratory Glass Columns "Next Generation" technology for high-performance preparative chromatography

    E-Print Network [OSTI]

    Lebendiker, Mario

    SNAP ® Laboratory Glass Columns "Next Generation" technology for high-performance preparative lesiones graves o la muerte! WARNING Glass SNAP® columns are intended for use in a liquid environment disassembly or cleaning for scratches, chips or defects, particularly on the glass surfaces. DO NOT use column

  16. Analysis of Minimum Efficiency Performance Standards for Residential General Service Lighting in Chile

    E-Print Network [OSTI]

    Letschert, Virginie E.

    2012-01-01T23:59:59.000Z

    Standard for Residential Lighting in Chile, 2010 USResidential General Service Lighting in Chile Virginie E.focus on a regulation for lighting that would ban the sale

  17. Impact of the U.S. National Building Information Model Standard (NBIMS) on Building Energy Performance Simulation

    SciTech Connect (OSTI)

    Bazjanac, Vladimir

    2007-08-01T23:59:59.000Z

    The U.S. National Institute for Building Sciences (NIBS) started the development of the National Building Information Model Standard (NBIMS). Its goal is to define standard sets of data required to describe any given building in necessary detail so that any given AECO industry discipline application can find needed data at any point in the building lifecycle. This will include all data that are used in or are pertinent to building energy performance simulation and analysis. This paper describes the background that lead to the development of NBIMS, its goals and development methodology, its Part 1 (Version 1.0), and its probable impact on building energy performance simulation and analysis.

  18. Formulas for predicting the dynamic performance of ROCOF relays for embedded generation applications

    SciTech Connect (OSTI)

    Vieira, J.C. M.; Freitas, Walmir; Huang, Zhenyu; Xu, Wilsun; Morelato, A.

    2006-07-13T23:59:59.000Z

    A set of formulas directly predict the performance of rate-of-change-of-frequency (ROCOF) relays used to detect islanding of embedded synchronous generators. The formulas are analytically derived from the dynamic model of the generator and relay. Dynamic simulation results obtained using a representative distribution system confirm the validity and accuracy. The formulas presented are a useful tool for protection engineers; they can be used, for example, to assess the effectiveness of anti-islanding schemes based on ROCOF relays, or to assist the selection of relay settings, significantly reducing the number of repeated dynamic simulations necessary to carry out such studies.

  19. SAT Mathematics standardized test manual for high-performing high school students

    E-Print Network [OSTI]

    Vasquez, Phillip A

    2009-01-01T23:59:59.000Z

    Most high school standardized testing preparation materials are geared towards the average student scoring in the 5 0 th percentile. There are few resources available to lower and higher scoring students who have different ...

  20. Approaches to representing aircraft fuel efficiency performance for the purpose of a commercial aircraft certification standard

    E-Print Network [OSTI]

    Yutko, Brian M. (Brian Matthew)

    2011-01-01T23:59:59.000Z

    Increasing concern over the potential harmful effects of green house gas emissions from various sources has motivated the consideration of an aircraft certification standard as one way to reduce aircraft C02 emissions and ...

  1. Approaches to Representing Aircraft Fuel Efficiency Performance for the Purpose of a Commercial Aircraft Certification Standard

    E-Print Network [OSTI]

    Yutko, Brian

    2011-06-27T23:59:59.000Z

    Increasing concern over the potential harmful effects of green house gas emissions from various sources has motivated the consideration of an aircraft certification standard as one way to reduce aircraft CO2 emissions and ...

  2. Interconnection Standards

    Broader source: Energy.gov [DOE]

    In September 2007, the Washington Utilities and Transportation Commission (UTC) adopted interconnection standards for distributed generation (DG) systems up to 20 megawatts (MW) in capacity. The...

  3. Dynamic performance and control of a static var generator using cascade multilevel inverters

    SciTech Connect (OSTI)

    Peng, Fang Zheng [Tennessee Univ., Knoxville, TN (United States); Lai, Jih-Sheng [Oak Ridge National Lab., TN (United States)

    1996-10-01T23:59:59.000Z

    A cascade multilevel inverter is proposed for static VAR shifting, compensation/generation applications. The new cascade M-level inverter consists of (M-1)/2 single-phase full bridges in which each bridge has its own separate dc source. This inverter can generate almost sinusoidal waveform voltage with only one time switching per cycle. It can eliminate the need for transformers in multipulse inverters. A prototype static VAR generator (SVG) system using 11- level cascade inverter (21-level line-to-line voltage waveform) has been built. The output voltage waveform is equivalent to that of a 60- pulse inverter. This paper focuses on dynamic performance of the cascade inverter based SVG system. Control schemes are proposed to achieve a fast response which is impossible for a conventional static VAR compensator (SVC). Analytical, simulated and experimental results show the superiority of the proposed SVG system.

  4. Interconnection Standards

    Broader source: Energy.gov [DOE]

    Oregon has three separate interconnection standards: one for net-metered systems, one for small generator facilities (non-net metered systems) and one for large generator facilities (non-net...

  5. Graphene oxide functionalized with methylene blue and its performance in singlet oxygen generation

    SciTech Connect (OSTI)

    Wojtoniszak, M., E-mail: mwojtoniszak@zut.edu.pl [West Pomeranian University of Technology in Szczecin, Institute of Chemical and Environment Engineering, Pulaskiego 10, 70-322 Szczecin (Poland); Rogi?ska, D.; Machali?ski, B. [Pomeranian Medical University, Department of General Pathology, Powsta?ców Wlkp. 72, 70-111 Szczecin (Poland); Drozdzik, M. [Pomeranian Medical University, Department of Pharmacology, Powsta?ców Wlkp. 72, 70-111 Szczecin (Poland); Mijowska, E. [West Pomeranian University of Technology in Szczecin, Institute of Chemical and Environment Engineering, Pulaskiego 10, 70-322 Szczecin (Poland)

    2013-07-15T23:59:59.000Z

    Graphical abstract: - Highlights: • Adsorption of methylene blue (MB) on graphene oxide (GO). • Characterization of graphene oxide–methylene blue nanocomposite (MB–GO). • Examination of MB–GO efficiency in singlet oxygen generation (SOG). • MB–GO performs higher SOG efficiency than pristine MB. - Abstract: Due to unique electronic, mechanical, optical and structural properties, graphene has shown promising applications in many fields, including biomedicine. One of them is noninvasive anticancer therapy – photodynamic therapy (PDT), where singlet oxygen (SO), generated under the irradiation of light with appropriate wavelengths, kills cancer cells. In this study, authors report graphene oxide (GO) noncovalent functionalization with methylene blue (MB). MB molecules underwent adsorption on the surface of GO. Detailed characterization of the obtained material was carried out with UV–vis spectroscopy, Raman spectroscopy, FT-IR spectroscopy, and confocal laser scanning microscopy. Furthermore, its performance in singlet oxygen generation (SOG) under irradiation of laser with excitation wavelengths of 785 nm was investigated. Interestingly, GO functionalized with MB (MB–GO) showed enhanced efficiency in singlet oxygen generation compared to pristine MB. The efficiency in SOG was detected by photobleaching of 9,10-anthracenediyl-bis(methylene)dimalonic acid (ABMDMA). These results indicate the material is promising in PDT anticancer therapy and further in vitro and in vivo studies are required.

  6. Method and apparatus for improving the performance of a nuclear power electrical generation system

    DOE Patents [OSTI]

    Tsiklauri, Georgi V. (Richland, WA); Durst, Bruce M. (Kennewick, WA)

    1995-01-01T23:59:59.000Z

    A method and apparatus for improving the efficiency and performance a of nuclear electrical generation system that comprises the addition of steam handling equipment to an existing plant that results in a surprising increase in plant performance. More particularly, a gas turbine electrical generation system with heat recovery boiler is installed along with a high pressure and a low pressure mixer superheater. Depending upon plant characteristics, the existing moisture separator reheater (MSR) can be either augmented or done away with. The instant invention enables a reduction in T.sub.hot without a derating of the reactor unit, and improves efficiency of the plant's electrical conversion cycle. Coupled with this advantage is a possible extension of the plant's fuel cycle length due to an increased electrical conversion efficiency. The reduction in T.sub.hot further allows for a surprising extension of steam generator life. An additional advantage is the reduction in erosion/corrosion of secondary system components including turbine blades and diaphragms. The gas turbine generator used in the instant invention can also replace or augment existing peak or emergency power needs.

  7. APPLICATION OF IT AND INTERNATIONAL STANDARDS TO IMPROVE BUILDING ENVELOPE PERFORMANCE

    E-Print Network [OSTI]

    Hammad, Amin

    , Quebec, Canada ABSTRACT Improving thermal performance of building envelopes reduces energy consumption the thermal performance of the building envelope, e.g., the advanced house program from NRCan, better windows, and improved thermal performance of building envelopes. According to Hydro Quebec, house characteristics

  8. Requirements for Defining Utility Drive Cycles: An Exploratory Analysis of Grid Frequency Regulation Data for Establishing Battery Performance Testing Standards

    SciTech Connect (OSTI)

    Hafen, Ryan P.; Vishwanathan, Vilanyur V.; Subbarao, Krishnappa; Kintner-Meyer, Michael CW

    2011-10-19T23:59:59.000Z

    Battery testing procedures are important for understanding battery performance, including degradation over the life of the battery. Standards are important to provide clear rules and uniformity to an industry. The work described in this report addresses the need for standard battery testing procedures that reflect real-world applications of energy storage systems to provide regulation services to grid operators. This work was motivated by the need to develop Vehicle-to-Grid (V2G) testing procedures, or V2G drive cycles. Likewise, the stationary energy storage community is equally interested in standardized testing protocols that reflect real-world grid applications for providing regulation services. As the first of several steps toward standardizing battery testing cycles, this work focused on a statistical analysis of frequency regulation signals from the Pennsylvania-New Jersey-Maryland Interconnect with the goal to identify patterns in the regulation signal that would be representative of the entire signal as a typical regulation data set. Results from an extensive time-series analysis are discussed, and the results are explained from both the statistical and the battery-testing perspectives. The results then are interpreted in the context of defining a small set of V2G drive cycles for standardization, offering some recommendations for the next steps toward standardizing testing protocols.

  9. Background to the development process, Automated Residential Energy Standard (ARES) in support of proposed interim energy conservation voluntary performance standards for new non-federal residential buildings: Volume 3

    SciTech Connect (OSTI)

    NONE

    1989-09-01T23:59:59.000Z

    This report documents the development and testing of a set of recommendations generated to serve as a primary basis for the Congressionally-mandated residential standard. This report treats only the residential building recommendations.

  10. Performance study of a soft X-ray harmonic generation FEL seeded with an EUV laser pulse

    E-Print Network [OSTI]

    Wurtele, Jonathan

    Performance study of a soft X-ray harmonic generation FEL seeded with an EUV laser pulse M. Gullans electron laser (FEL) using a low-power extreme ultraviolet (EUV) pulse as an input seed is investigated generation schemes. It is found that, for reasonable beam parameters, robust FEL performance can be obtained

  11. Coal-fired high performance power generating system. Quarterly progress report, April 1--June 30, 1993

    SciTech Connect (OSTI)

    Not Available

    1993-11-01T23:59:59.000Z

    This report covers work carried out under Task 2, Concept Definition and Analysis, Task 3, Preliminary R&D and Task 4, Commercial Generating Plant Design, under Contract AC22-92PC91155, ``Engineering Development of a Coal Fired High Performance Power Generation System`` between DOE Pittsburgh Energy Technology Center and United Technologies Research Center. The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of: >47% thermal efficiency; NO{sub x}, SO{sub x} and Particulates {le}25% NSPS; cost {ge}65% of heat input; all solid wastes benign. In order to achieve these goals our team has outlined a research plan based on an optimized analysis of a 250 MW{sub e} combined cycle system applicable to both frame type and aeroderivative gas turbines. Under the constraints of the cycle analysis we have designed a high temperature advanced furnace (HITAF) which integrates several combustor and air heater designs with appropriate ash management procedures. A survey of currently available high temperature alloys has been completed and some of their high temperature properties are shown for comparison. Several of the most promising candidates will be selected for testing to determine corrosion resistance and high temperature strength. The corrosion resistance testing of candidate refractory coatings is continuing and some of the recent results are presented. This effort will provide important design information that will ultimately establish the operating ranges of the HITAF.

  12. High performance liquid desiccant cooling system simulation at standard ARI conditions

    E-Print Network [OSTI]

    McDonald, Brian Francis

    1991-01-01T23:59:59.000Z

    of the standard vapor compression system are cryogenic cooling, non fluorocarbon refrigerants and desiccant cooling. Navy scientists have been investigating the use of sound waves for cryogenic cooling. The "cryo-cooler" uses water as the working fluid... and thus eliminates the possibility of fluorocarbon emissions. However, initial research shows that the system requires about the same amount of electricity as contemporary refrigeration models [2]. Non fluorocarbon refrigerants are used as a...

  13. NREL: Performance and Reliability R&D - Industry Workshop and Standards

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for Renewable Energy: Grid Integration NRELCost of Automotive FuelStandardsSupport for

  14. Coal-fired high performance power generating system. Quarterly progress report, January 1--March 31, 1992

    SciTech Connect (OSTI)

    Not Available

    1992-12-31T23:59:59.000Z

    This report covers work carried out under Task 2, Concept Definition and Analysis, and Task 3, Preliminary R and D, under contract DE-AC22-92PC91155, ``Engineering Development of a Coal Fired High Performance Power Generation System`` between DOE Pittsburgh Energy Technology Center and United Technologies Research Center. The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of: > 47% thermal efficiency; NO{sub x}, SO{sub x} and Particulates {le} 25% NSPS; cost {ge} 65% of heat input; and all solid wastes benign. In order to achieve these goals our team has outlined a research plan based on an optimized analysis of a 250 MW{sub e} combined cycle system applicable to both frame type and aeroderivative gas turbines. Under the constraints of the cycle analysis we have designed a high temperature advanced furnace (FHTAF) which integrates several combustor and air heater designs with appropriate ash management procedures. The cycle optimization effort has brought about several revisions to the system configuration resulting from: (1) the use of Illinois No. 6 coal instead of Utah Blind Canyon; (2) the use of coal rather than methane as a reburn fuel; (3) reducing radiant section outlet temperatures to 1700F (down from 1800F); and (4) the need to use higher performance (higher cost) steam cycles to offset losses introduced as more realistic operating and construction constraints are identified.

  15. Current industry standards and practices for qualification of NDE personnel -- What is performance demonstration telling us?

    SciTech Connect (OSTI)

    Kellerhall, R.A. [SubSea International Inc., Corpus Christi, TX (United States). NDE Services

    1996-12-31T23:59:59.000Z

    This paper presents an overview of the most commonly used documents relating to qualification requirements for personnel who perform nondestructive examination (NDE), primarily ultrasonic (UT) examination in the oil and gas, petrochemical, and power industries. Nondestructive examination has been used for many years to ascertain the condition of a wide variety of components. An essential element in the effectiveness of nondestructive examination is the qualification of the personnel who are responsible for and who perform nondestructive examinations. One of the most effective methods of ascertaining the proficiency of equipment, procedures, and personnel is by a performance demonstration conducted on samples containing actual flaws. In the last 10 to 15 years, performance demonstrations have indicated the level of proficiency of personnel to be considerably lower than had been thought.

  16. Experimental Investigation of the Power Generation Performance of Floating-Point Absorber Wave Energy Systems: Preprint

    SciTech Connect (OSTI)

    Li, Y.; Yu, Y.; Epler, J.; Previsic, M.

    2012-04-01T23:59:59.000Z

    The extraction of energy from ocean waves has gained interest in recent years. The floating-point absorber (FPA) is one of the most promising devices among a wide variety of wave energy conversion technologies. Early theoretical studies mainly focused on understanding the hydrodynamics of the system and on predicting the maximum power that could be extracted by a heaving body. These studies evolve from the investigation of floating-body interactions in offshore engineering and naval architecture disciplines. To our best knowledge, no systematic study has been reported about the investigation of the power generation performance of an FPA with a close-to-commercial design. A series of experimental tests was conducted to investigate the power extraction performance of an FPA system.

  17. Standard Test Methods for Measurement of Electrical Performance and Spectral Response of Nonconcentrator Multijunction Photovoltaic Cells and Modules

    E-Print Network [OSTI]

    American Society for Testing and Materials. Philadelphia

    2010-01-01T23:59:59.000Z

    1.1 These test methods provide special techniques needed to determine the electrical performance and spectral response of two-terminal, multijunction photovoltaic (PV) devices, both cell and modules. 1.2 These test methods are modifications and extensions of the procedures for single-junction devices defined by Test Methods E948, E1021, and E1036. 1.3 These test methods do not include temperature and irradiance corrections for spectral response and current-voltage (I-V) measurements. Procedures for such corrections are available in Test Methods E948, E1021, and E1036. 1.4 These test methods may be applied to cells and modules intended for concentrator applications. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and ...

  18. Standard Test Method for Electrical Performance of Concentrator Terrestrial Photovoltaic Modules and Systems Under Natural Sunlight

    E-Print Network [OSTI]

    American Society for Testing and Materials. Philadelphia

    2009-01-01T23:59:59.000Z

    1.1 This test method covers the determination of the electrical performance of photovoltaic concentrator modules and systems under natural sunlight using a normal incidence pyrheliometer. 1.2 The test method is limited to module assemblies and systems where the geometric concentration ratio specified by the manufacturer is greater than 5. 1.3 This test method applies to concentrators that use passive cooling where the cell temperature is related to the air temperature. 1.4 Measurements under a variety of conditions are allowed; results are reported under a select set of concentrator reporting conditions to facilitate comparison of results. 1.5 This test method applies only to concentrator terrestrial modules and systems. 1.6 This test method assumes that the module or system electrical performance characteristics do not change during the period of test. 1.7 The performance rating determined by this test method applies only at the period of the test, and implies no past or future performance level. 1.8...

  19. Interim Report: Air-Cooled Condensers for Next Generation Geothermal Power Plants Improved Binary Cycle Performance

    SciTech Connect (OSTI)

    Daniel S. Wendt; Greg L. Mines

    2010-09-01T23:59:59.000Z

    As geothermal resources that are more expensive to develop are utilized for power generation, there will be increased incentive to use more efficient power plants. This is expected to be the case with Enhanced Geothermal System (EGS) resources. These resources will likely require wells drilled to depths greater than encountered with hydrothermal resources, and will have the added costs for stimulation to create the subsurface reservoir. It is postulated that plants generating power from these resources will likely utilize the binary cycle technology where heat is rejected sensibly to the ambient. The consumptive use of a portion of the produced geothermal fluid for evaporative heat rejection in the conventional flash-steam conversion cycle is likely to preclude its use with EGS resources. This will be especially true in those areas where there is a high demand for finite supplies of water. Though they have no consumptive use of water, using air-cooling systems for heat rejection has disadvantages. These systems have higher capital costs, reduced power output (heat is rejected at the higher dry-bulb temperature), increased parasitics (fan power), and greater variability in power generation on both a diurnal and annual basis (larger variation in the dry-bulb temperature). This is an interim report for the task ‘Air-Cooled Condensers in Next- Generation Conversion Systems’. The work performed was specifically aimed at a plant that uses commercially available binary cycle technologies with an EGS resource. Concepts were evaluated that have the potential to increase performance, lower cost, or mitigate the adverse effects of off-design operation. The impact on both cost and performance were determined for the concepts considered, and the scenarios identified where a particular concept is best suited. Most, but not all, of the concepts evaluated are associated with the rejection of heat. This report specifically addresses three of the concepts evaluated: the use of recuperation, the use of turbine reheat, and the non-consumptive use of EGS make-up water to supplement heat rejection

  20. PERFORMANCE TESTING OF THE NEXT-GENERATION CSSX SOLVENT WITH ACTUAL SRS TANK WASTE

    SciTech Connect (OSTI)

    Pierce, R.; Peters, T.; Crowder, M.; Fink, S.

    2011-11-01T23:59:59.000Z

    Efforts are underway to qualify the Next-Generation Solvent for the Caustic Side Solvent Extraction (CSSX) process. Researchers at multiple national laboratories have been involved in this effort. As part of the effort to qualify the solvent extraction system at the Savannah River Site (SRS), SRNL performed a number of tests at various scales. First, SRNL completed a series of batch equilibrium, or Extraction-Scrub-Strip (ESS), tests. These tests used {approx}30 mL of Next-Generation Solvent and either actual SRS tank waste, or waste simulant solutions. The results from these cesium mass transfer tests were used to predict solvent behavior under a number of conditions. At a larger scale, SRNL assembled 12 stages of 2-cm (diameter) centrifugal contactors. This rack of contactors is structurally similar to one tested in 2001 during the demonstration of the baseline CSSX process. Assembly and mechanical testing found no issues. SRNL performed a nonradiological test using 35 L of cesium-spiked caustic waste simulant and 39 L of actual tank waste. Test results are discussed; particularly those related to the effectiveness of extraction.

  1. Standard Test Methods for Electrical Performance of Nonconcentrator Terrestrial Photovoltaic Modules and Arrays Using Reference Cells

    E-Print Network [OSTI]

    American Society for Testing and Materials. Philadelphia

    2008-01-01T23:59:59.000Z

    1.1 These test methods cover the electrical performance of photovoltaic modules and arrays under natural or simulated sunlight using a calibrated reference cell. 1.1.1 These test methods allow a reference module to be used instead of a reference cell provided the reference module has been calibrated using these test methods against a calibrated reference cell. 1.2 Measurements under a variety of conditions are allowed; results are reported under a select set of reporting conditions (RC) to facilitate comparison of results. 1.3 These test methods apply only to nonconcentrator terrestrial modules and arrays. 1.4 The performance parameters determined by these test methods apply only at the time of the test, and imply no past or future performance level. 1.5 These test methods apply to photovoltaic modules and arrays that do not contain series-connected photovoltaic multijunction devices; such module and arrays should be tested according to Test Methods E 2236. 1.6 The values stated in SI units are to be re...

  2. Standard Test Method for Determining Thermal Performance of Tracking Concentrating Solar Collectors

    E-Print Network [OSTI]

    American Society for Testing and Materials. Philadelphia

    1987-01-01T23:59:59.000Z

    1.1 This test method covers the determination of thermal performance of tracking concentrating solar collectors that heat fluids for use in thermal systems. 1.2 This test method applies to one- or two-axis tracking reflecting concentrating collectors in which the fluid enters the collector through a single inlet and leaves the collector through a single outlet, and to those collectors where a single inlet and outlet can be effectively provided, such as into parallel inlets and outlets of multiple collector modules. 1.3 This test method is intended for those collectors whose design is such that the effects of diffuse irradiance on performance is negligible and whose performance can be characterized in terms of direct irradiance. Note 1—For purposes of clarification, this method shall apply to collectors with a geometric concentration ratio of seven or greater. 1.4 The collector may be tested either as a thermal collection subsystem where the effects of tracking errors have been essentially removed from t...

  3. SAND94-2862C PERFORMANCE CHARACTERIZATION OF THE NASA STANDARD DETONATOR*

    Office of Scientific and Technical Information (OSTI)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOnItem Not Found Item Not Foundenhancer activity than FINALSAND94-2862C PERFORMANCE

  4. Performance of the fusion code GYRO on four generations of Cray computers

    SciTech Connect (OSTI)

    Fahey, Mark R [ORNL] [ORNL

    2014-01-01T23:59:59.000Z

    GYRO is a code used for the direct numerical simulation of plasma microturbulence. It has been ported to a variety of modern MPP platforms including several modern commodity clusters, IBM SPs, and Cray XC, XT, and XE series machines. We briefly describe the mathematical structure of the equations, the data layout, and the redistribution scheme. Also, while the performance and scaling of GYRO on many of these systems has been shown before, here we show the comparative performance and scaling on four generations of Cray supercomputers including the newest addition - the Cray XC30. The more recently added hybrid OpenMP/MPI imple- mentation also shows a great deal of promise on custom HPC systems that utilize fast CPUs and proprietary interconnects. Four machines of varying sizes were used in the experiment, all of which are located at the National Institute for Computational Sciences at the University of Tennessee at Knoxville and Oak Ridge National Laboratory. The advantages, limitations, and performance of using each system are discussed.

  5. Implementing Performance-Based Sustainability Requirements for the Low Carbon Fuel Standard – Key Design Elements and Policy Considerations

    E-Print Network [OSTI]

    Yeh, Sonia; Sumner, Daniel A.; Kaffka, Stephen R.; Ogden, J; Jenkins, Bryan M.

    2009-01-01T23:59:59.000Z

    ultra low-GHG second-generation biofuels from organic wasteis needed in second-generation biofuels. 2. Participatingthe actual impacts of second-generation biofuels will depend

  6. Interconnection Standards

    Broader source: Energy.gov [DOE]

    Utah’s interconnection rules are based on the Federal Energy Regulatory Commission’s (FERC) interconnection standards for small generators, adopted in May 2005 by FERC Order 2006. Utah's rules for...

  7. Interconnection Standards

    Broader source: Energy.gov [DOE]

    Vermont has adopted separate interconnection standards for net-metered energy systems that are 150 kW or less, and for all other distributed-generation (DG) systems.

  8. Improving the lifetime performance of ceramic fuel cells Fuel cells generate electricity from fuels more efficiently and with

    E-Print Network [OSTI]

    Rollins, Andrew M.

    2014 Improving the lifetime performance of ceramic fuel cells Fuel cells generate electricity from to produce electricity from fuels. To speed the search for why fuel cell performance decreases over time fuels more efficiently and with fewer emissions per watt than burning fossil fuels. But as fuel cells

  9. Potential Impact of Adopting Maximum Technologies as Minimum Efficiency Performance Standards in the U.S. Residential Sector

    SciTech Connect (OSTI)

    Letschert, Virginie; Desroches, Louis-Benoit; McNeil, Michael; Saheb, Yamina

    2010-05-03T23:59:59.000Z

    The US Department of Energy (US DOE) has placed lighting and appliance standards at a very high priority of the U.S. energy policy. However, the maximum energy savings and CO2 emissions reduction achievable via minimum efficiency performance standards (MEPS) has not yet been fully characterized. The Bottom Up Energy Analysis System (BUENAS), first developed in 2007, is a global, generic, and modular tool designed to provide policy makers with estimates of potential impacts resulting from MEPS for a variety of products, at the international and/or regional level. Using the BUENAS framework, we estimated potential national energy savings and CO2 emissions mitigation in the US residential sector that would result from the most aggressive policy foreseeable: standards effective in 2014 set at the current maximum technology (Max Tech) available on the market. This represents the most likely characterization of what can be maximally achieved through MEPS in the US. The authors rely on the latest Technical Support Documents and Analytical Tools published by the U.S. Department of Energy as a source to determine appliance stock turnover and projected efficiency scenarios of what would occur in the absence of policy. In our analysis, national impacts are determined for the following end uses: lighting, television, refrigerator-freezers, central air conditioning, room air conditioning, residential furnaces, and water heating. The analyzed end uses cover approximately 65percent of site energy consumption in the residential sector (50percent of the electricity consumption and 80percent of the natural gas and LPG consumption). This paper uses this BUENAS methodology to calculate that energy savings from Max Tech for the U.S. residential sector products covered in this paper will reach an 18percent reduction in electricity demand compared to the base case and 11percent in Natural Gas and LPG consumption by 2030 The methodology results in reductions in CO2 emissions of a similar magnitude.

  10. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation: Functional modules, F9-F11

    SciTech Connect (OSTI)

    NONE

    1997-03-01T23:59:59.000Z

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U.S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This volume consists of the section of the manual dealing with three of the functional modules in the code. Those are the Morse-SGC for the SCALE system, Heating 7.2, and KENO V.a. The manual describes the latest released versions of the codes.

  11. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation: Control modules C4, C6

    SciTech Connect (OSTI)

    NONE

    1997-03-01T23:59:59.000Z

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U. S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This volume is part of the manual related to the control modules for the newest updated version of this computational package.

  12. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation: Functional modules F1-F8

    SciTech Connect (OSTI)

    NONE

    1997-03-01T23:59:59.000Z

    This Manual represents Revision 5 of the user documentation for the modular code system referred to as SCALE. The history of the SCALE code system dates back to 1969 when the current Computational Physics and Engineering Division at Oak Ridge National Laboratory (ORNL) began providing the transportation package certification staff at the U.S. Atomic Energy Commission with computational support in the use of the new KENO code for performing criticality safety assessments with the statistical Monte Carlo method. From 1969 to 1976 the certification staff relied on the ORNL staff to assist them in the correct use of codes and data for criticality, shielding, and heat transfer analyses of transportation packages. However, the certification staff learned that, with only occasional use of the codes, it was difficult to become proficient in performing the calculations often needed for an independent safety review. Thus, shortly after the move of the certification staff to the U.S. Nuclear Regulatory Commission (NRC), the NRC staff proposed the development of an easy-to-use analysis system that provided the technical capabilities of the individual modules with which they were familiar. With this proposal, the concept of the Standardized Computer Analyses for Licensing Evaluation (SCALE) code system was born. This volume consists of the section of the manual dealing with eight of the functional modules in the code. Those are: BONAMI - resonance self-shielding by the Bondarenko method; NITAWL-II - SCALE system module for performing resonance shielding and working library production; XSDRNPM - a one-dimensional discrete-ordinates code for transport analysis; XSDOSE - a module for calculating fluxes and dose rates at points outside a shield; KENO IV/S - an improved monte carlo criticality program; COUPLE; ORIGEN-S - SCALE system module to calculate fuel depletion, actinide transmutation, fission product buildup and decay, and associated radiation source terms; ICE.

  13. Engineering evaluation and analysis for the improvement of military standard generators. Volume 1. Final report, 24 February-29 May 1987

    SciTech Connect (OSTI)

    Adolph, R.J.; Lawrence, L.G.; Perkins, G.W.; Thorwaldson, E.

    1987-05-29T23:59:59.000Z

    This Final Report provides an in-depth look at on-going projects for improving the Mobile Electric-Power-Generating System (MEPGS) sets. A detailed comparison of existing MEPGS requirements for generators against proposed requirements for commercial generators procured for tactical military use is presented. From this comparison, a list of areas and characteristics of the MEPGS sets, which fall short of the requirements imposed by the draft Required Operational Capability (ROC) document are presented. Major areas include: noise, reliability, Electro Magnetic Pulse (EMP), and built-in test equipment. This report analyzes industry response and suggestions for improvement of the MPEGS set family. Respondents' suggestions fell primarily in the areas of Reliability, Noise and Infrared (IR) suppression. The majority of recommended actions were general in nature, but the vendors were consistent in the areas they felt could be improved. Design modifications are proposed for all MEPGS sets considered in this study to upgrade the requirements in the areas of noise suppression and reliability. Major emphasis is placed on improvements to the 15-, 30-, and 60-kW generator sets.

  14. Performance Comparison of Three-and Five-Phase Permanent Magnet Generators for Marine Current

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Turbine Applications Under Open-Circuit Faults Seifeddine Benelghali, Fatiha Mekri, Mohamed Benbouzid a marine current turbine and compared to a classical three-phase generator. For both topologies, a robust generators key features marine applications. Index Terms--Marine Current Turbine MCT), five-phase Permanent

  15. An hourly-based performance comparison of an integrated micro-structural perforated shading screen with standard shading systems

    E-Print Network [OSTI]

    Appelfeld, David

    2013-01-01T23:59:59.000Z

    values of the performance indicators, e.g. total solarare the fundamental performance indicators for CFS and all11. Table 2. Energy performance indicators of selected CFS

  16. Use of Performance Monitoring to Improve Reliability of Emergency Generators Diesel

    E-Print Network [OSTI]

    Dulik, J. D.

    Emergency diesel generators are one of the most important contributors to the core damage failure rate of nuclear power plants. Current required testing and maintenance procedures are excessively strict and expensive without ...

  17. Opto-electronic device for frequency standard generation and terahertz-range optical demodulation based on quantum interference

    DOE Patents [OSTI]

    Georgiades, Nikos P. (Pasadena, CA); Polzik, Eugene S. (H.o slashed.jbjerg, DK); Kimble, H. Jeff (LaCanada, CA)

    1999-02-02T23:59:59.000Z

    An opto-electronic system and technique for comparing laser frequencies with large frequency separations, establishing new frequency standards, and achieving phase-sensitive detection at ultra high frequencies. Light responsive materials with multiple energy levels suitable for multi-photon excitation are preferably used for nonlinear mixing via quantum interference of different excitation paths affecting a common energy level. Demodulation of a carrier with a demodulation frequency up to 100's THZ can be achieved for frequency comparison and phase-sensitive detection. A large number of materials can be used to cover a wide spectral range including the ultra violet, visible and near infrared regions. In particular, absolute frequency measurement in a spectrum from 1.25 .mu.m to 1.66 .mu.m for fiber optics can be accomplished with a nearly continuous frequency coverage.

  18. Opto-electronic device for frequency standard generation and terahertz-range optical demodulation based on quantum interference

    DOE Patents [OSTI]

    Georgiades, N.P.; Polzik, E.S.; Kimble, H.J.

    1999-02-02T23:59:59.000Z

    An opto-electronic system and technique for comparing laser frequencies with large frequency separations, establishing new frequency standards, and achieving phase-sensitive detection at ultra high frequencies are disclosed. Light responsive materials with multiple energy levels suitable for multi-photon excitation are preferably used for nonlinear mixing via quantum interference of different excitation paths affecting a common energy level. Demodulation of a carrier with a demodulation frequency up to 100`s THZ can be achieved for frequency comparison and phase-sensitive detection. A large number of materials can be used to cover a wide spectral range including the ultra violet, visible and near infrared regions. In particular, absolute frequency measurement in a spectrum from 1.25 {micro}m to 1.66 {micro}m for fiber optics can be accomplished with a nearly continuous frequency coverage. 7 figs.

  19. Generation of primordial cosmological density inhomogeneities with scale invariant power spectrum during the standard radiation dominated expansion of the universe

    E-Print Network [OSTI]

    Oaknin, David H

    2007-01-01T23:59:59.000Z

    The expansion/contraction of a bubble of gas of radius $R_0(t)$ immersed in an incompressible fluid that fills the infinite 3D space around it, $r \\ge R_0(t)$, generates a radial flow, ${\\vec v}(r,t) = \\frac{R^2_0(t)}{r^2}\\ \\dot{R}_0(t) {\\hat r}$, which is set by the velocity of the bubble surface, $\\dot{R}_0(t)$. The kinetic energy that the expanding/contracting bubble pumps, at the expense of its own internal energy, into each unit volume of the flowing incompressible fluid is ${\\it e}(r,t) = \\frac{\\rho_0}{2} |{\\vec v}(r,t)|^2 = \\frac{\\rho_0}{2} \\dot{R}^2_0(t) R^4_0(t) r^{-4}$, where $\\rho_0$ is the mass density of the fluid. This incompressible flow generates equal time energy density (anti)correlations over infinitely long distances. They are imposed by global conservation laws and, therefore, do not violate causality. We notice that energy density inhomogeneities that are (anti)correlated as $f(r) \\sim - r^{-4}$ as $r \\to \\infty$ have scale invariant power spectrum in the range of very small wavenumbers,...

  20. Coal-fired high performance power generating system. Draft quarterly progress report, January 1--March 31, 1995

    SciTech Connect (OSTI)

    NONE

    1995-10-01T23:59:59.000Z

    This report covers work carried out under Task 3, Preliminary R and D, under contract DE-AC22-92PC91155, ``Engineering Development of a Coal-Fired High Performance Power Generation System`` between DOE Pittsburgh Energy Technology Center and United Technologies Research Center. The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of >47% thermal efficiency; NO{sub x}, SO{sub x} and particulates {le} 25% NSPS; cost {ge}65% of heat input; all solid wastes benign. A crucial aspect of the authors design is the integration of the gas turbine requirements with the HITAF output and steam cycle requirements. In order to take full advantage of modern highly efficient aeroderivative gas turbines they have carried out a large number of cycle calculations to optimize their commercial plant designs for both greenfield and repowering applications.

  1. On The Impact of Communication Delays on Power System Automatic Generation Control Performance

    E-Print Network [OSTI]

    Liberzon, Daniel

    to become more prevalent in electric power systems. With increased integration of information technology (IT the IT infrastructure of a power system [1], is sensitive to such emerging behaviors, which, in turn, could have signals to generators through the IT infrastructure. The goal of the AGC system is to regulate electrical

  2. Development and performance evaluation of an electromagnetic-type shock wave generator for lipolysis

    SciTech Connect (OSTI)

    Liang, S. M., E-mail: liangsm@cc.feu.edu.tw; Yang, Z. Y. [Department of Industrial Design, Far East University, No. 49, Zhonghua Road, Xinshi District, Tainan City 744, Taiwan (China)] [Department of Industrial Design, Far East University, No. 49, Zhonghua Road, Xinshi District, Tainan City 744, Taiwan (China); Chang, M. H. [Department of Aeronautics and Astronautics, National Cheng Kung University, No. 1, University Road, East District, Tainan City 701, Taiwan (China)] [Department of Aeronautics and Astronautics, National Cheng Kung University, No. 1, University Road, East District, Tainan City 701, Taiwan (China)

    2014-01-15T23:59:59.000Z

    This study aims at the design and development of electromagnetic-type intermittent shock wave generation in a liquid. The shock wave generated is focused at a focal point through an acoustic lens. This hardware device mainly consists of a full-wave bridge rectifier, 6 capacitors, a spark gap, and a flat coil. A metal disk is mounted in a liquid-filled tube and is placed in close proximity to the flat coil. Due to the repulsive force existing between the coil and disk shock waves are generated, while an eddy current is induced in the metal disk. Some components and materials associated with the device are also described. By increasing the capacitance content to enhance electric energy level, a highly focused pressure can be achieved at the focal point through an acoustic lens in order to lyse fat tissue. Focused pressures were measured at the focal point and its vicinity for different operation voltages. The designed shock wave generator with an energy intensity of 0.0016 mJ/mm{sup 2} (at 4 kV) and 2000 firings or higher energy intensities with 1000 firings is found to be able to disrupt pig fat tissue.

  3. Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee—image quality and diagnostic performance

    E-Print Network [OSTI]

    2009-01-01T23:59:59.000Z

    standard 2D imaging at 3.0 T of the knee—image quality andMR imaging was performed at 3.0 T in 50 patients. Imagesat 1.5 T, while we used 3.0 T, which can potentially enhance

  4. Superior Processes at Industrial Equipment Manufacturers Benchmark best practices and performances for next-generation success

    E-Print Network [OSTI]

    Narasayya, Vivek

    Superior Processes at Industrial Equipment Manufacturers Benchmark best practices and performances invest time, effort and resources in establishing the best practices, technology systems and solutions at a pace faster than the competition. · Engaged people/human capital acquisition, development

  5. High Performance Fuel Design for Next Generation PWRs 2nd Annual Report

    E-Print Network [OSTI]

    Ballinger, Ronald G.

    The overall objective of this NERI project is to examine the potential for a high performance advanced fuel design for Pressurized Water Reactors (PWRs), which would accommodate a substantial increase of core power density ...

  6. High Performance Fuel Design for Next Generation PWRs: 11th Quarterly Report

    E-Print Network [OSTI]

    Kazimi, Mujid S.

    I. Technical Narrative: The overall objective of this NERI project is to examine the potential for a high performance advanced fuel for Pressurized Water Reactors (PWRs), which would accommodate a substantial increase of ...

  7. Achieving New Source Performance Standards (NSPS) Emission Standards Through Integration of Low-NOx Burners with an Optimization Plan for Boiler Combustion

    SciTech Connect (OSTI)

    Wayne Penrod

    2006-12-31T23:59:59.000Z

    The objective of this project was to demonstrate the use of an Integrated Combustion Optimization System to achieve NO{sub X} emission levels in the range of 0.15 to 0.22 lb/MMBtu while simultaneously enabling increased power output. The project plan consisted of the integration of low-NO{sub X} burners and advanced overfire air technology with various process measurement and control devices on the Holcomb Station Unit 1 boiler. The plan included the use of sophisticated neural networks or other artificial intelligence technologies and complex software to optimize several operating parameters, including NO{sub X} emissions, boiler efficiency, and CO emissions. The program was set up in three phases. In Phase I, the boiler was equipped with sensors that can be used to monitor furnace conditions and coal flow to permit improvements in boiler operation. In Phase II, the boiler was equipped with burner modifications designed to reduce NO{sub X} emissions and automated coal flow dampers to permit on-line fuel balancing. In Phase III, the boiler was to be equipped with an overfire air system to permit deep reductions in NO{sub X} emissions. Integration of the overfire air system with the improvements made in Phases I and II would permit optimization of boiler performance, output, and emissions. This report summarizes the overall results from Phases I and II of the project. A significant amount of data was collected from the combustion sensors, coal flow monitoring equipment, and other existing boiler instrumentation to monitor performance of the burner modifications and the coal flow balancing equipment.

  8. Post-editing is commonly performed on computer-generated texts, whether from Machine Translation

    E-Print Network [OSTI]

    forecasts for offshore oilrigs. Table 1 shows a small extract from the NWP data for 12-06-2002, and Table 2 shows part of the textual forecast that SUMTIME-MOUSAM generates from the NWP data. The Wind statements in Table 2 are mostly based on the NWP data in Table 1. Time Wind Dir Wind Spd 10m Wind Spd 50m Gust 10m

  9. High-performance single-photon generation with commercial-grade optical fiber

    E-Print Network [OSTI]

    Christoph Söller; Offir Cohen; Brian J. Smith; Ian A. Walmsley; Christine Silberhorn

    2012-02-14T23:59:59.000Z

    High-quality quantum sources are of paramount importance for the implementation of quantum technologies. We present here a heralded single-photon source based on commercial-grade polarization-maintaining optical fiber. The heralded photons exhibit a purity of at least 0.84 and an unprecedented heralding efficiency into single-mode fiber of 85%. The birefringent phase-matching condition of the underlying four-wave mixing process can be controlled mechanically to optimize the wavelength tuning needed for interfacing multiple sources, as are required for large-scale entanglement generation.

  10. Generating audio-responsive video images in real-time for a live symphony performance

    E-Print Network [OSTI]

    Beane, Allison Brooke

    2007-09-17T23:59:59.000Z

    instruments to cutting-edge video image productions for musical groups of all sizes. Throughout this evolution, a common goal has been to create real-time, audio-responsive visuals that accentuate the sound and enhance the performance. This paper explains...

  11. Construction cost impact analysis of the U.S. Department of Energy mandatory performance standards for new federal commercial and multi-family, high-rise residential buildings

    SciTech Connect (OSTI)

    Di Massa, F.V.; Hadley, D.L.; Halverson, M.A.

    1993-12-01T23:59:59.000Z

    In accordance with federal legislation, the U.S. Department of Energy (DOE) has conducted a project to demonstrate use of its Energy Conservation Voluntary Performance Standards for Commercial and Multi-Family High-Rise Residential Buildings; Mandatory for New Federal Buildings; Interim Rule (referred to in this report as DOE-1993). A key requisite of the legislation requires DOE to develop commercial building energy standards that are cost effective. During the demonstration project, DOE specifically addressed this issue by assessing the impacts of the standards on (1) construction costs, (2) builders (and especially small builders) of multi-family, high-rise buildings, and (3) the ability of low-to moderate-income persons to purchase or rent units in such buildings. This document reports on this project.

  12. Implementing Performance-Based Sustainability Requirements for the Low Carbon Fuel Standard – Key Design Elements and Policy Considerations

    E-Print Network [OSTI]

    Yeh, Sonia; Sumner, Daniel A.; Kaffka, Stephen R.; Ogden, J; Jenkins, Bryan M.

    2009-01-01T23:59:59.000Z

    2008a. Draft Sustainability Framework for AB118 Projects.a performance-based sustainability framework that setsstandard. The sustainability framework should adopt a

  13. Implementing Performance-Based Sustainability Requirements for the Low Carbon Fuel Standard – Key Design Elements and Policy Considerations

    E-Print Network [OSTI]

    Yeh, Sonia; Sumner, Daniel A.; Kaffka, Stephen R.; Ogden, J; Jenkins, Bryan M.

    2009-01-01T23:59:59.000Z

    potential social and environmental damage and unintendedof Potential Economic Damages. Environmental Science &and environmental performance, and minimize the risk of damages

  14. Renewable Power Options for Electrical Generation on Kaua'i: Economics and Performance Modeling

    SciTech Connect (OSTI)

    Burman, K.; Keller, J.; Kroposki, B.; Lilienthal, P.; Slaughter, R.; Glassmire, J.

    2011-11-01T23:59:59.000Z

    The Hawaii Clean Energy Initiative (HCEI) is working with a team led by the U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to assess the economic and technical feasibility of increasing the contribution of renewable energy in Hawaii. This part of the HCEI project focuses on working with Kaua'i Island Utility Cooperative (KIUC) to understand how to integrate higher levels of renewable energy into the electric power system of the island of Kaua'i. NREL partnered with KIUC to perform an economic and technical analysis and discussed how to model PV inverters in the electrical grid.

  15. HYDROGEN GENERATION FROM SLUDGE SAMPLE BOTTLES CAUSED BY RADIOLYSIS AND CHEMISTRY WITH CONCETNRATION DETERMINATION IN A STANDARD WASTE BOX (SWB) OR DRUM FOR TRANSPORT

    SciTech Connect (OSTI)

    RILEY DL; BRIDGES AE; EDWARDS WS

    2010-03-30T23:59:59.000Z

    A volume of 600 mL of sludge, in 4.1 L sample bottles (Appendix 7.6), will be placed in either a Super Pig (Ref. 1) or Piglet (Ref. 2, 3) based on shielding requirements (Ref. 4). Two Super Pigs will be placed in a Standard Waste Box (SWB, Ref. 5), as their weight exceeds the capacity of a drum; two Piglets will be placed in a 55-gallon drum (shown in Appendix 7.2). The generation of hydrogen gas through oxidation/corrosion of uranium metal by its reaction with water will be determined and combined with the hydrogen produced by radiolysis. The hydrogen concentration in the 55-gallon drum and SWB will be calculated to show that the lower flammability limit of 5% hydrogen is not reached. The inner layers (i.e., sample bottle, bag and shielded pig) in the SWB and drum will be evaluated to assure no pressurization occurs as the hydrogen vents from the inner containers (e.g., shielded pigs, etc.). The reaction of uranium metal with anoxic liquid water is highly exothermic; the heat of reaction will be combined with the source term decay heat, calculated from Radcalc, to show that the drum and SWB package heat load limits are satisfied. This analysis does five things: (1) Estimates the H{sub 2} generation from the reaction of uranium metal with water; (2) Estimates the H{sub 2} generation from radiolysis (using Radcalc 4.1); (3) Combines both H{sub 2} generation amounts, from Items 1 and 2, and determines the percent concentration of H{sub 2} in the interior of an SWB with two Super Pigs, and the interior of a 55-gallon drum with two Piglets; (4) From the combined gas generation rate, shows that the pressure at internal layers is minimal; and (5) Calculates the maximum thermal load of the package, both from radioactive decay of the source and daughter products as calculated/reported by Radcalc 4.1, and from the exothermic reaction of uranium metal with water.

  16. Particulate Matter Standards (Ohio)

    Broader source: Energy.gov [DOE]

    This chapter of the law establishes that the Ohio Environmental Protection Agency sets the standards for particulate emissions from a variety of sources, including facilities that generate power. ...

  17. NEW SOURCE PERFORMANCE STANDARDS -NOVEMBER15,1982 ------m m m u m ~ U U -k d -

    E-Print Network [OSTI]

    (D) 1. Fossil-Fuel Fired Steam 2. Fossil-Fuel Fired Steam Generators (Da) 3. Incinerators (municipal Smelters (Q) Affected facility a. Fluid catalytic cracking unit catalyst torsneratorsregenerators c. Fuel gas combustion device ( § GO.100) d. Claus sulfur recovery plants (> 20 LTD/day) Storage capacity

  18. High Temperature Leakage Performance of a Hybrid Brush Seal Compared to a Standard Brush Seal and a Labyrinth Seal

    E-Print Network [OSTI]

    Ashton, Zachary

    2010-01-14T23:59:59.000Z

    design that adds to the bristle brush matrix a number of cantilever pads that rest on the rotor surface. Upon shaft rotation the pads lift due to the generation of a hydrodynamic gas film while the brushes effectively seal an upstream pressure. Hence...

  19. Covanta Begins Operating Nation's First Energy-from-Waste Unit under the EPA's New Source Performance Standards

    E-Print Network [OSTI]

    Columbia University

    Sampson, Director of Lee County's Solid Waste Division. Working with Lee County, Covanta oversaw. Mr. Orlando said Covanta was proud to be part of Lee County's comprehensive solid waste management generation projects. Covanta's energy-from-waste facilities convert municipal solid waste into renewable

  20. Generation IV benchmarking of TRISO fuel performance models under accident conditions. Modeling input data

    SciTech Connect (OSTI)

    Blaise Collin

    2014-09-01T23:59:59.000Z

    This document presents the benchmark plan for the calculation of particle fuel performance on safety testing experiments that are representative of operational accidental transients. The benchmark is dedicated to the modeling of fission product release under accident conditions by fuel performance codes from around the world, and the subsequent comparison to post-irradiation experiment (PIE) data from the modeled heating tests. The accident condition benchmark is divided into three parts: the modeling of a simplified benchmark problem to assess potential numerical calculation issues at low fission product release; the modeling of the AGR-1 and HFR-EU1bis safety testing experiments; and, the comparison of the AGR-1 and HFR-EU1bis modeling results with PIE data. The simplified benchmark case, thereafter named NCC (Numerical Calculation Case), is derived from ''Case 5'' of the International Atomic Energy Agency (IAEA) Coordinated Research Program (CRP) on coated particle fuel technology [IAEA 2012]. It is included so participants can evaluate their codes at low fission product release. ''Case 5'' of the IAEA CRP-6 showed large code-to-code discrepancies in the release of fission products, which were attributed to ''effects of the numerical calculation method rather than the physical model''[IAEA 2012]. The NCC is therefore intended to check if these numerical effects subsist. The first two steps imply the involvement of the benchmark participants with a modeling effort following the guidelines and recommendations provided by this document. The third step involves the collection of the modeling results by Idaho National Laboratory (INL) and the comparison of these results with the available PIE data. The objective of this document is to provide all necessary input data to model the benchmark cases, and to give some methodology guidelines and recommendations in order to make all results suitable for comparison with each other. The participants should read this document thoroughly to make sure all the data needed for their calculations is provided in the document. Missing data will be added to a revision of the document if necessary.

  1. Development and Performance Evaluation of High Temperature Concrete for Thermal Energy Storage for Solar Power Generation

    SciTech Connect (OSTI)

    R. Panneer Selvam, Micah Hale and Matt strasser

    2013-03-31T23:59:59.000Z

    Thermal energy can be stored by the mechanism of sensible or latent heat or heat from chemical reactions. Sensible heat is the means of storing energy by increasing the temperature of the solid or liquid. Since the concrete as media cost per kWhthermal is $1, this seems to be a very economical material to be used as a TES. This research is focused on extending the concrete TES system for higher temperatures (500 �ºC to 600 �ºC) and increasing the heat transfer performance using novel construction techniques. To store heat at high temperature special concretes are developed and tested for its performance. The storage capacity costs of the developed concrete is in the range of $0.91-$3.02/kWhthermal Two different storage methods are investigated. In the first one heat is transported using molten slat through a stainless steel tube and heat is transported into concrete block through diffusion. The cost of the system is higher than the targeted DOE goal of $15/kWhthermal The increase in cost of the system is due to stainless steel tube to transfer the heat from molten salt to the concrete blocks.The other method is a one-tank thermocline system in which both the hot and cold fluid occupy the same tank resulting in reduced storage tank volume. In this model, heated molten salt enters the top of the tank which contains a packed bed of quartzite rock and silica sand as the thermal energy storage (TES) medium. The single-tank storage system uses about half the salt that is required by the two-tank system for a required storage capacity. This amounts to a significant reduction in the cost of the storage system. The single tank alternative has also been proven to be cheaper than the option which uses large concrete modules with embedded heat exchangers. Using computer models optimum dimensions are determined to have an round trip efficiency of 84%. Additionally, the cost of the structured concrete thermocline configuration provides the TES capacity cost of $33.80$/kWhthermal compared with $30.04/kWhthermal for a packed-bed thermocline (PBTC) configuration and $46.11/kWhthermal for a two-tank liquid configuration.

  2. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Miscellaneous -- Volume 3, Revision 4

    SciTech Connect (OSTI)

    Petrie, L.M.; Jordon, W.C. [Oak Ridge National Lab., TN (United States); Edwards, A.L. [Oak Ridge National Lab., TN (United States)]|[Lawrence Livermore National Lab., CA (United States)] [and others

    1995-04-01T23:59:59.000Z

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice; (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System developments has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. This manual is divided into three volumes: Volume 1--for the control module documentation, Volume 2--for the functional module documentation, and Volume 3--for the data libraries and subroutine libraries.

  3. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Control modules -- Volume 1, Revision 4

    SciTech Connect (OSTI)

    Landers, N.F.; Petrie, L.M.; Knight, J.R. [Oak Ridge National Lab., TN (United States)] [and others

    1995-04-01T23:59:59.000Z

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. This manual is divided into three volumes: Volume 1--for the control module documentation, Volume 2--for the functional module documentation, and Volume 3 for the documentation of the data libraries and subroutine libraries.

  4. Coal-fired high performance power generating system. Quarterly progress report, October 1, 1994--December 31, 1994

    SciTech Connect (OSTI)

    NONE

    1995-08-01T23:59:59.000Z

    This report covers work carried out under Task 3, Preliminary R and D, under contract DE-AC22-92PC91155, {open_quotes}Engineering Development of a Coal-Fired High Performance Power Generation System{close_quotes} between DOE Pittsburgh Energy Technology Center and United Technologies Research Center. The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of (1) > 47% thermal efficiency; (2) NO{sub x}, SO{sub x} and particulates {<=}25% NSPS; (3) cost {>=}65% of heat input; (4) all solid wastes benign. In our design consideration, we have tried to render all waste streams benign and if possible convert them to a commercial product. It appears that vitrified slag has commercial values. If the flyash is reinjected through the furnace, along with the dry bottom ash, then the amount of the less valuable solid waste stream (ash) can be minimized. A limitation on this procedure arises if it results in the buildup of toxic metal concentrations in either the slag, the flyash or other APCD components. We have assembled analytical tools to describe the progress of specific toxic metals in our system. The outline of the analytical procedure is presented in the first section of this report. The strengths and corrosion resistance of five candidate refractories have been studied in this quarter. Some of the results are presented and compared for selected preparation conditions (mixing, drying time and drying temperatures). A 100 hour pilot-scale stagging combustor test of the prototype radiant panel is being planned. Several potential refractory brick materials are under review and five will be selected for the first 100 hour test. The design of the prototype panel is presented along with some of the test requirements.

  5. Got Standards? "Got Standards?"

    E-Print Network [OSTI]

    Vardeman, Stephen B.

    certifications available. Some of these certifications include ISO 9002 1994, ISO 9003 1994 and ISO 9001 in order to bring harmony to global standards for international trade. Enter ISO 9000. The Basics In order to fully understand the concept of ISO 9000, it is very important to have a good idea of what a standard is

  6. RADIOLOGICAL HEALTH AND RELATED STANDARDS FOR NUCLEAR POWER PLANTS. VOLUME 2 OF HEALTH AND SAFETY IMPACTS OF NUCLEAR, GEOTHERMAL, AND FOSSIL-FUEL ELECTRIC GENERATION IN CALIFORNIA

    E-Print Network [OSTI]

    Nero, A.V.

    2010-01-01T23:59:59.000Z

    IMPACTS OF NUCLEAR, GEOTHERMAL, AND FOSSIL-FUEL ELECTRIC GENERATION IN CALIFORNIA Energy and Environment

  7. Steam generation in line-focus solar collectors: a comparative assessment of thermal performance, operating stability, and cost issues

    SciTech Connect (OSTI)

    Murphy, L.M.; May, E.K.

    1982-04-01T23:59:59.000Z

    The engineering and system benefits of using direct steam (in situ) generation in line-focus collectors are assessed. The major emphasis of the analysis is a detailed thermal performance comparison of in situ systems (which utilize unfired boilers). The analysis model developed for this study is discussed in detail. An analysis of potential flow stability problems is also provided along with a cursory cost analysis and an assessment of freeze protection, safety, and control issues. Results indicated a significant thermal performance advantage over the more conventional oil and flash systems and the flow stability does not appear to be a significant problem. In particular, at steam temperatures of 220/sup 0/C (430/sup 0/F) under the chosen set of assumptions, annual delivered energy predictions indicate that the in situ system can deliver 15% more energy than an oil system and 12% more energy than a flash system, with all of the systems using the same collector field. Further, the in situ system may result in a 10% capital cost reduction. Other advantages include improvement in simpler control when compared with flash systems, and fluid handling and safety enhancement when compared with oil systems.

  8. VALIDATION OF ANSI N42.34 AMERICAN NATIONAL STANDARD PERFORMANCE CRITERIA FOR HAND-HELD INSTRUMENTS FOR THE DETECTION AND IDENTIFICATION OF RADIONUCLIDES

    SciTech Connect (OSTI)

    Lorier, T.

    2014-09-03T23:59:59.000Z

    SRNL’s validation of ANSI N42.34-D6 for the Domestic Nuclear Detection Office (DNDO) was performed utilizing one hand-held instrument (or RID) – the FLIR identiFINDER 2. Each section of the standard was evaluated via a walk-through or test. NOTE: In Table 1, W = walk-through and T = test, as directed by the Domestic Nuclear Detection Office (DNDO). For a walk-through, the experiment was either setup or reviewed for setup; for a test, the N42.34-D6 procedures were followed with some exceptions and comments noted. SRNL is not fully able to evaluate a RID against Sections 7 (Environmental), 8 (Electromagnetic), and 9 (Mechanical) of N42.34, so those portions of this validation were done in collaboration with Qualtest, Inc. in Orlando, Florida. The walk-throughs and tests of Sections 7, 8, and 9 were performed in Qualtest, Inc. facilities with SRNL providing radiological sources as necessary. Where applicable, assessment results and findings of the walk-throughs and tests were recorded on datasheets and a validation summary is provided. A general comment pertained to test requirements found in another standard and referenced in N42.34-D6. For example, step 1 of the test method in section 8.1.2 states “RF test set up information can be found in IEC 61000-4-3.” It is recommended that any information from other standards necessary for conducting the tests within N42.34 should be posted in N42.34 for simplicity and to prevent the user from having to peruse other documents. Another general comment, as noted by Qualtest, is that a tolerance reference is not listed for each test in sections 7-9. Overall, the N42.34-D6 was proven to be practicable, but areas for improvement and recommendations were identified for consideration prior to final ballot submittal.

  9. Performance study of a soft X-ray harmonic generation FEL seeded with an EUV laser pulse

    E-Print Network [OSTI]

    Gullans, M.; Wurtele, J.S.; Penn, G.; Zholents, A.A.

    2007-01-01T23:59:59.000Z

    X-ray Harmonic Generation FEL Seeded with an EUV Laser PulseX-ray harmonic generation FEL seeded with an EUV laser pulseof a free electron laser (FEL) using a low-power extreme

  10. Low-Cost Superconducting Wire for Wind Generators: High Performance, Low Cost Superconducting Wires and Coils for High Power Wind Generators

    SciTech Connect (OSTI)

    None

    2012-01-01T23:59:59.000Z

    REACT Project: The University of Houston will develop a low-cost, high-current superconducting wire that could be used in high-power wind generators. Superconducting wire currently transports 600 times more electric current than a similarly sized copper wire, but is significantly more expensive. The University of Houston’s innovation is based on engineering nanoscale defects in the superconducting film. This could quadruple the current relative to today’s superconducting wires, supporting the same amount of current using 25% of the material. This would make wind generators lighter, more powerful and more efficient. The design could result in a several-fold reduction in wire costs and enable their commercial viability of high-power wind generators for use in offshore applications.

  11. Improving Vortex Generators to Enhance the Performance of Air-Cooled Condensers in a Geothermal Power Plant

    SciTech Connect (OSTI)

    Manohar S. Sohal

    2005-09-01T23:59:59.000Z

    This report summarizes work at the Idaho National Laboratory to develop strategies to enhance air-side heat transfer in geothermal air-cooled condensers such that it should not significantly increase pressure drop and parasitic fan pumping power. The work was sponsored by the U.S. Department of Energy, NEDO (New Energy and Industrial Technology Development Organization) of Japan, Yokohama National University, and the Indian Institute of Technology, Kanpur, India. A combined experimental and numerical investigation was performed to investigate heat transfer enhancement techniques that may be applicable to largescale air-cooled condensers such as those used in geothermal power applications. A transient heat transfer visualization and measurement technique was employed in order to obtain detailed distributions of local heat transfer coefficients on model fin surfaces. Pressure drop measurements were obtained for a variety of tube and winglet configurations using a single-channel flow apparatus that included four tube rows in a staggered array. Heat transfer and pressure drop measurements were also acquired in a separate multiple-tube row apparatus in the Single Blow Test Facility. In addition, a numerical modeling technique was developed to predict local and average heat transfer for these low-Reynolds number flows, with and without winglets. Representative experimental and numerical results were obtained that reveal quantitative details of local finsurface heat transfer in the vicinity of a circular tube with a single delta winglet pair downstream of the cylinder. Heat transfer and pressure-drop results were obtained for flow Reynolds numbers based on channel height and mean flow velocity ranging from 700 to 6500. The winglets were of triangular (delta) shape with a 1:2 or 1:3 height/length aspect ratio and a height equal to 90% of the channel height. Overall mean fin-surface heat transfer results indicate a significant level of heat transfer enhancement (in terms of Colburn j-factor) associated with deployment of the winglets with circular as well as oval tubes. In general, toe-in (common flow up) type winglets appear to have better performance than the toe-out (common flow down) type winglets. Comparisons of heat transfer and pressure drop results for the elliptical tube versus a circular tube with and without winglets are provided. During the course of their independent research, all of the researchers have established that about 10 to 30% enhancement in Colburn j-factor is expected. However, actual increase in heat transfer rate from a heat exchanger employing finned tubes with winglets may be smaller, perhaps on the order of 2 to 5%. It is also concluded that for any specific application, more full-size experimentation is needed to optimize the winglet design for a specific heat exchanger application. If in place of a circular tube, an oval tube can be economically used in a bundle, it is expected that the pressure drop across the tube bundle with the application of vortex generators (winglets) will be similar to that in a conventional circular tube bundle. It is hoped that the results of this research will demonstrate the benefits of applying vortex generators (winglets) on the fins to improve the heat transfer from the air-side of the tube bundle.

  12. RADIOLOGICAL HEALTH AND RELATED STANDARDS FOR NUCLEAR POWER PLANTS. VOLUME 2 OF HEALTH AND SAFETY IMPACTS OF NUCLEAR, GEOTHERMAL, AND FOSSIL-FUEL ELECTRIC GENERATION IN CALIFORNIA

    E-Print Network [OSTI]

    Nero, A.V.

    2010-01-01T23:59:59.000Z

    in U. S. Conunercial Nuclear Power Plants", Report WASH-Related Standards for Nuclear Power Plants," by A.V. NeroResponse Planning for Nuclear Power Plants in California,"

  13. RADIOLOGICAL HEALTH AND RELATED STANDARDS FOR NUCLEAR POWER PLANTS. VOLUME 2 OF HEALTH AND SAFETY IMPACTS OF NUCLEAR, GEOTHERMAL, AND FOSSIL-FUEL ELECTRIC GENERATION IN CALIFORNIA

    E-Print Network [OSTI]

    Nero, A.V.

    2010-01-01T23:59:59.000Z

    Report LBL-5287. "Power Plant Reliability-Availability andConunercial Nuclear Power Plants", Report WASH-1400 (NUREG-Standards for Nuclear Power Plants," by A.V. Nero and Y.C.

  14. Domestic olivine vs magnesite as a thermal-energy-storage material: performance comparisons for electrically heated room-size units in accordance with ASHRAE Standard 94. 2

    SciTech Connect (OSTI)

    Laster, W.R.; Schoenhals, R.J.; Gay, B.M.; Palmour, H. III

    1982-01-01T23:59:59.000Z

    Electrically heated thermal-energy-storage (TES) heaters employing high-heat-capacity ceramic refractories for sensible heat storage have been in use in Europe for several years. With these heaters, low cost off-peak electrical energy is stored by heating a storage core composed of ceramic material to approximately 800/sup 0/C. During the peak period, no electrical energy is used as the building heating needs are supplied by extracting the stored heat from the core by forced air circulation. Recently significant interest in the use of off-peak TES units in the US has occured, leading to the search for a domestic supply of high heat capacity ceramic refractory material. North Carolina's extensive but under-utilized supply of refractory grade olivine has been proposed as a source of storage material for these units. In this paper, the suitability of North Carolina olivine for heat-storage applications is assessed by comparing its thermal performance with that of European materials. Using the method of ASHRAE Standard 94.2, the thermal performance of two small room-sized commercially available TES units was determined experimentally with two different storage materials, North Carolina olivine and German magnesite. Comparisons between the two materials are made and conclusions are drawn.

  15. Technical support documentation for the Automated Residential Energy Standard (ARES) data base in support of proposed interim energy conservation voluntary performance standards for new non-federal residential buildings: Volume 4

    SciTech Connect (OSTI)

    NONE

    1989-09-01T23:59:59.000Z

    This report focuses on those areas where substantial improvements have been made in simulation techniques or analysis of results concerning the Automated Residential Energy Standard (ARES).

  16. Published in proceedings of the 1996 EUROSIM Int'l Conf., June 10--12, 1996, Delft, The Netherlands, pp. 421--428. Automatic Code Generation for High Performance Computing in

    E-Print Network [OSTI]

    van Engelen, Robert A.

    , The Netherlands, pp. 421--428. Automatic Code Generation for High Performance Computing in Environmental Modeling Robert van Engelen a#+ , Lex Wolters a+# , and Gerard Cats b# a High Performance Computing Division, Dept: cats@knmi.nl In this paper we will discuss automatic code generation for high performance computer

  17. Interconnection Standards

    Broader source: Energy.gov [DOE]

    New York first adopted uniform interconnection standards in 1999 (see history below). The Standard Interconnection Requirements (SIR) have subsequently been amended several times since, most...

  18. Interconnection Standards

    Broader source: Energy.gov [DOE]

    The Pennsylvania Public Utilities Commission was required to adopt interconnection standards and net-metering rules by the Alternative Energy Portfolio Standards Act of 2004.The PUC subsequently...

  19. Interconnection Standards

    Broader source: Energy.gov [DOE]

    Tier 1 systems must include an inverter certified to meet the Underwriters Laboratories (UL) 1741 standard

  20. Estimate of Cost-Effective Potential for Minimum Efficiency Performance Standards in 13 Major World Economies Energy Savings, Environmental and Financial Impacts

    E-Print Network [OSTI]

    Letschert, Virginie E.

    2013-01-01T23:59:59.000Z

    Retail Data Brazil – International Energy Initiative Life-business as usual Brazil Bottom-Up Energy Analysis Systemfor setting energy efficiency standards in Brazil:The case

  1. Environmental Restoration Program pollution prevention performance measures for FY 1993 and 1994 remedial investigations: Generator training manual

    SciTech Connect (OSTI)

    Not Available

    1993-03-01T23:59:59.000Z

    This computer-based program is designed to help waste generators in the Environmental Restoration (ER) Program prevent pollution at the DOE Oak Ridge Field Office (DOE-OR) facilities in Oak Ridge, Paducah, and Portsmouth. The Numerical Scoring System (NSS) is an interactive system designed to maintain data on ER Program pollution prevention efforts and to measure the success of these efforts through the ER Program life cycle.

  2. Interconnection Standards

    Broader source: Energy.gov [DOE]

    West Virginia's interconnection standards include two levels of review. The qualifications and application fees for each level are as follows:...

  3. Customer-Focused Innovation in High Tech Industries Benchmark best practices and performances for next-generation success

    E-Print Network [OSTI]

    Narasayya, Vivek

    . · Engaged people/human capital acquisition, development, and retention: Secure a competitive performance: Develop and manage supply chains and partnerships that provide flexibility, response time, and delivery manufacturing principles, it all begins with clearly identifying and attempting to satisfy customer demand

  4. Energy Standards for State Buildings

    Broader source: Energy.gov [DOE]

    The State is still required by statute to adopt planning and construction standards for state buildings that conserve energy and optimize the energy performance of new buildings. The standards mu...

  5. Wind Turbinie Generator System Power Performance Test Report for the Mariah Windspire 1-kW Wind Turbine

    SciTech Connect (OSTI)

    Huskey, A.; Bowen, A.; Jager, D.

    2009-12-01T23:59:59.000Z

    This report summarizes the results of a power performance test that NREL conducted on the Mariah Windspire 1-kW wind turbine. During this test, two configurations were tested on the same turbine. In the first configuration, the turbine inverter was optimized for power production. In the second configuration, the turbine inverter was set for normal power production. In both configurations, the inverter experienced failures and the tests were not finished.

  6. Interconnection Standards

    Broader source: Energy.gov [DOE]

    The New Hampshire Public Utilities Commission’s (PUC) rules for net metering, which distinguish between small customer-generators (up to 100 kilowatts) and large customer-generators (greater than...

  7. Interconnection Standards

    Broader source: Energy.gov [DOE]

    The interconnection standards approved by the PUC also updated Nevada's net-metering policy, originally enacted in 1997. Previously, Nevada Revised Statute 704.774 addressed basic interconnection...

  8. Interconnection Standards

    Broader source: Energy.gov [DOE]

    New Jersey's interconnection standards apply statewide to all electric distribution utilities, but not to the small number of municipal utilities and electric cooperatives in the state. The rules,...

  9. Interconnection Standards

    Broader source: Energy.gov [DOE]

    Virginia has two interconnection standards: one for net-metered systems and one for systems that are not net-metered.

  10. Interconnection Standards

    Broader source: Energy.gov [DOE]

    In December 2005, the Colorado Public Utilities Commission (PUC) adopted standards for net metering and interconnection, as required by Amendment 37, a renewable-energy ballot initiative approved...

  11. Dynamic Analysis of Hybrid Energy Systems under Flexible Operation and Variable Renewable Generation -- Part I: Dynamic Performance Analysis and Part II: Dynamic Cost

    SciTech Connect (OSTI)

    Humberto E. Garcia; Amit Mohanty; Wen-Chiao Lin; Robert S. Cherry

    2013-04-01T23:59:59.000Z

    Dynamic analysis of hybrid energy systems (HES) under flexible operation and variable renewable generation is considered in order to better understand various challenges and opportunities associated with the high system variability arising from the integration of renewable energy into the power grid. Unique consequences are addressed by devising advanced HES solutions in which multiple forms of energy commodities, such as electricity and chemical products, may be exchanged. Dynamic models of various unit operations are developed and integrated within two different HES options. One HES option, termed traditional, produces electricity only and consists of a primary heat generator (PHG) (e.g., a small modular reactor), a steam turbine generator, a wind farm, and a battery storage. The other HES option, termed advanced, includes not only the components present in the traditional option but also a chemical plant complex to repurpose excess energy for non-electricity services, such as for the production of chemical goods (e.g., transportation fuel). In either case, a given HES is connected to the power grid at a point of common coupling and requested to deliver a certain electricity generation profile as dictated by a regional power grid operator based on a predicted demand curve. Dynamic analysis of these highly-coupled HES are performed to identify their key dynamical properties and limitations and to prescribe solutions for best managing and mitigating the high variability introduced from incorporating renewable energy into the energy mix. A comparative dynamic cost analysis is also conducted to determine best HES options. The cost function includes a set of metrics for computing fixed costs, such as fixed operations and maintenance (O&M) and overnight capital costs, and also variable operational costs, such as cost of variability, variable O&M cost, and cost of environmental impact, together with revenues. Assuming different options for implementing PHG (e.g., natural gas, coal, nuclear), preliminary results identify the level of renewable penetration at which a given advanced HES option (e.g., a nuclear hybrid) becomes increasingly more economical than a traditional electricity-only generation solution. Conditions are also revealed under which carbon resources may be better utilized as carbon sources for chemical production rather than as combustion material for electricity generation.

  12. SCALE: A modular code system for performing Standardized Computer Analyses for Licensing Evaluation. Volume 2, Part 3: Functional modules F16--F17; Revision 5

    SciTech Connect (OSTI)

    NONE

    1997-03-01T23:59:59.000Z

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automated the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.3 of the system.

  13. Interconnection Standards

    Broader source: Energy.gov [DOE]

    The Iowa Utilities Board (IUB) adopted rules for utilities in May 2010 for the interconnection of distributed generation facilities in Iowa.

  14. Interconnection Standards

    Broader source: Energy.gov [DOE]

    In November 2005, the Indiana Utility Regulatory Commission (IURC) approved rules governing the interconnection of distributed generation (DG). Indiana's interconnection rules require the state's...

  15. Interconnection Standards

    Broader source: Energy.gov [DOE]

    In July 2006 the District of Columbia Public Service Commission (PSC) initiated a formal inquiry into the development of uniform interconnection procedures for on-site distributed generation...

  16. Physical Surveys of Over 300 Buildings in Hot and Humid Climates Indicate Material/Design Performance Flaws Exist in Comparison to Expected Results Using Nationally Accepted Standards

    E-Print Network [OSTI]

    Othmer, A. E.

    2000-01-01T23:59:59.000Z

    and tape recorder ready, every lighting fixture wattage, thermostat location, return air duct system, window size, with type and orientation, along with every millimeter of missing caulking and door sealant are recorded for evaluation. Using standard... conservation methods that employ their rebate program materials1 devices and private vendors. Our program has the ability to suggest different conservation measures, that can be categorized as no or low cost to the end user. END RESULTS (ACTUAL SAVINGS...

  17. Dynamic Simulation Studies of the Frequency Response of the Three U.S. Interconnections with Increased Wind Generation

    E-Print Network [OSTI]

    Mackin, Peter

    2011-01-01T23:59:59.000Z

    on work performed by the WECC Wind Generator Modeling GroupModeling Approach in the WECC. ” IEEE Transactions on PowerNational Laboratory. 11. WECC. 2008. WECC Standard BAL-002-

  18. Interconnection Standards

    Broader source: Energy.gov [DOE]

    The PUC standards generally apply to investor-owned utilities (IOUs) with 40,000 or more customers and all electric cooperatives. Municipal utilities with 5,000 customers or more are required to ...

  19. Interconnection Standards

    Broader source: Energy.gov [DOE]

    NOTE: In Feb 2014, the PUC proposed changes to the State’s Alternative Energy Portfolio Standard, Interconnection, and Net-metering rules. The documents associated with the case can be accessed at...

  20. american national standards: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Health Services 12;12;Environmental Public Health Performance Standards (Version 2.0) Updated May 2014 12;Environmental Public Health Performance Standards 255 Status of...

  1. Deployment of a Suite of High-Performance Computational Tools for Multi-scale Multi-physics Simulation of Generation IV Reactors

    SciTech Connect (OSTI)

    Podowski, Michael Z

    2013-01-03T23:59:59.000Z

    The overall objective of this project has been to deploy advanced simulation capabilities for next generation reactor systems utilizing newly available, high-performance computing facilities. The approach includes the following major components: The development of new simulation capabilities using state-of-the-art computer codes of different scales: molecular dynamics (MD) level, DNS (FronTier and PHASTA) and CFD (NPHASE-CMFD); The development of advanced numerical solvers for large-size computational problems; The deployment of a multiple-code computational platform for multiscale simulations of gas/liquid two-phase flow during reactor transients and accidents; and Application of the new computational methodology to study the progression of loss-of-flow accident in sodium fast reactor (SFR).

  2. Performances of a large mass ZnMoO4 scintillating bolometer for a next generation neutrinoless double beta decay experiment

    E-Print Network [OSTI]

    J. W. Beeman; F. Bellini; C. Brofferio; L. Cardani; N. Casali; O. Cremonesi; I. Dafinei; S. Di Domizio; F. Ferroni; E. Gorello; E. N. Galashov; L. Gironi; S. S. Nagorny; F. Orio; M. Pavan; L. Pattavina; G. Pessina; G. Piperno; S. Pirro; E. Previtali; C. Rusconi; V. N. Shlegel; C. Tomei; M. Vignati

    2012-07-02T23:59:59.000Z

    We present the performances of a 330 g zinc molybdate (ZnMoO4) crystal working as scintillating bolometer as a possible candidate for a next generation experiment to search for neutrinoless double beta decay of 100Mo. The energy resolution, evaluated at the 2615 keV gamma-line of 208Tl, is 6.3 keV FWHM. The internal radioactive contaminations of the ZnMoO4 were evaluated as <6 microBq/kg (228Th) and 27\\pm6 microBq/kg (226Ra). We also present the results of the alpha vs beta/gamma discrimination, obtained through the scintillation light as well as through the study of the shape of the thermal signal alone.

  3. Final report for %22High performance computing for advanced national electric power grid modeling and integration of solar generation resources%22, LDRD Project No. 149016.

    SciTech Connect (OSTI)

    Reno, Matthew J.; Riehm, Andrew Charles; Hoekstra, Robert John; Munoz-Ramirez, Karina; Stamp, Jason Edwin; Phillips, Laurence R.; Adams, Brian M.; Russo, Thomas V.; Oldfield, Ron A.; McLendon, William Clarence, III; Nelson, Jeffrey Scott; Hansen, Clifford W.; Richardson, Bryan T.; Stein, Joshua S.; Schoenwald, David Alan; Wolfenbarger, Paul R.

    2011-02-01T23:59:59.000Z

    Design and operation of the electric power grid (EPG) relies heavily on computational models. High-fidelity, full-order models are used to study transient phenomena on only a small part of the network. Reduced-order dynamic and power flow models are used when analysis involving thousands of nodes are required due to the computational demands when simulating large numbers of nodes. The level of complexity of the future EPG will dramatically increase due to large-scale deployment of variable renewable generation, active load and distributed generation resources, adaptive protection and control systems, and price-responsive demand. High-fidelity modeling of this future grid will require significant advances in coupled, multi-scale tools and their use on high performance computing (HPC) platforms. This LDRD report demonstrates SNL's capability to apply HPC resources to these 3 tasks: (1) High-fidelity, large-scale modeling of power system dynamics; (2) Statistical assessment of grid security via Monte-Carlo simulations of cyber attacks; and (3) Development of models to predict variability of solar resources at locations where little or no ground-based measurements are available.

  4. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Functional modules F9--F16 -- Volume 2, Part 2, Revision 4

    SciTech Connect (OSTI)

    West, J.T.; Hoffman, T.J.; Emmett, M.B.; Childs, K.W.; Petrie, L.M.; Landers, N.F.; Bryan, C.B.; Giles, G.E. [Oak Ridge National Lab., TN (United States)

    1995-04-01T23:59:59.000Z

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. The manual is divided into three volumes: Volume 1--for the control module documentation, Volume 2--for functional module documentation; and Volume 3--for documentation of the data libraries and subroutine libraries. This volume discusses the following functional modules: MORSE-SGC; HEATING 7.2; KENO V.a; JUNEBUG-II; HEATPLOT-S; REGPLOT 6; PLORIGEN; and OCULAR.

  5. SCALE: A modular code system for performing standardized computer analyses for licensing evaluation. Functional modules F1--F8 -- Volume 2, Part 1, Revision 4

    SciTech Connect (OSTI)

    Greene, N.M.; Petrie, L.M.; Westfall, R.M.; Bucholz, J.A.; Hermann, O.W.; Fraley, S.K. [Oak Ridge National Lab., TN (United States)

    1995-04-01T23:59:59.000Z

    SCALE--a modular code system for Standardized Computer Analyses Licensing Evaluation--has been developed by Oak Ridge National Laboratory at the request of the US Nuclear Regulatory Commission. The SCALE system utilizes well-established computer codes and methods within standard analysis sequences that (1) allow an input format designed for the occasional user and/or novice, (2) automate the data processing and coupling between modules, and (3) provide accurate and reliable results. System development has been directed at problem-dependent cross-section processing and analysis of criticality safety, shielding, heat transfer, and depletion/decay problems. Since the initial release of SCALE in 1980, the code system has been heavily used for evaluation of nuclear fuel facility and package designs. This revision documents Version 4.2 of the system. The manual is divided into three volumes: Volume 1--for the control module documentation; Volume 2--for functional module documentation; and Volume 3--for documentation of the data libraries and subroutine libraries.

  6. Exploiting Third Generation Quarks for New Physics Discoveries at the Energy Frontier

    SciTech Connect (OSTI)

    Ivanov, Andrew G. [KSU] (ORCID:0000000292705643)

    2013-10-15T23:59:59.000Z

    The K-State group's effort is top quark physics and searches for beyond-standard-model physics in t{anti #22;}t final states. The KSU team performed the most precise measurement of the t#22;{anti t} cross section in the lepton + jets channel, and for the first time excluded the fourth generation of the standard model in the perturbative regime.

  7. Interconnection Standards

    Broader source: Energy.gov [DOE]

    Fees for interconnection requests increase with each Level. A Level 1 request must submit $50 fee; a Level 2 request must submit a fee of $50 plus $1/kW of generator capacity; a Level 3 request m...

  8. Interconnection Standards

    Broader source: Energy.gov [DOE]

    In February 2011, the DPU opened up a docket to examine net metering and interconnection of distributed generation. While the intent is to make changes to net metering, issues relating to interco...

  9. Interconnection Standards

    Broader source: Energy.gov [DOE]

    Utah requires the state's only investor-owned utility, Rocky Mountain Power (RMP), and most electric cooperatives* to offer net metering to customers who generate electricity using solar energy,...

  10. Interconnection Standards

    Broader source: Energy.gov [DOE]

    New Hampshire requires all utilities selling electricity in the state to offer net metering to customers who own or operate systems up to one megawatt (1 MW) in capacity that generate electricity...

  11. Interconnection Standards

    Broader source: Energy.gov [DOE]

    The Texas Public Utility Regulatory Act (PURA) of 1999 included a provision that "a customer is entitled to have access to on-site distributed generation". As a result, the Public Utility...

  12. Interconnection Standards

    Broader source: Energy.gov [DOE]

    Different rules govern the interconnection of distributed generation facilities in Iowa, depending on whether or not the interconnection is with a utility whose rates are regulated by the Iowa...

  13. Suggested performance specifications of standard modular controls for the automation of small hydro electric facilities. [Plant capacities from 50 kW to 15 MW

    SciTech Connect (OSTI)

    Beckwith, R.W.

    1980-06-01T23:59:59.000Z

    These specifications are made available by the Department of Energy for the voluntary use by any person, corporation or governmental body in the writing of purchase specifications for the automatic control of small hydro generating stations, i.e., hydro plants ranging in size from 50 kW to 15 MW. It is believed that the use of these specifications will permit competition among capable vendors and, at the same time, assure proper and reliable operation of both the automation hardware and software purchased. The specifications are detailed to a degree which should assure the interchangeability of hardware and software from various suppliers. This also increases the likelihood that spare parts and service will be available for many years. The specifications are written in modules, each of which can be included or excluded for ease of editing to match a particular application. Brief but detailed instructions are included for such editing. An extensive appendix gives the alternatives which were considered and reasons for the various choices specified.

  14. Development of a high-performance coal-fired power generating system with pyrolysis gas and char-fired high temperature furnace (HITAF). Volume 1, Final report

    SciTech Connect (OSTI)

    NONE

    1996-02-01T23:59:59.000Z

    A major objective of the coal-fired high performance power systems (HIPPS) program is to achieve significant increases in the thermodynamic efficiency of coal use for electric power generation. Through increased efficiency, all airborne emissions can be decreased, including emissions of carbon dioxide. High Performance power systems as defined for this program are coal-fired, high efficiency systems where the combustion products from coal do not contact the gas turbine. Typically, this type of a system will involve some indirect heating of gas turbine inlet air and then topping combustion with a cleaner fuel. The topping combustion fuel can be natural gas or another relatively clean fuel. Fuel gas derived from coal is an acceptable fuel for the topping combustion. The ultimate goal for HIPPS is to, have a system that has 95 percent of its heat input from coal. Interim systems that have at least 65 percent heat input from coal are acceptable, but these systems are required to have a clear development path to a system that is 95 percent coal-fired. A three phase program has been planned for the development of HIPPS. Phase 1, reported herein, includes the development of a conceptual design for a commercial plant. Technical and economic feasibility have been analysed for this plant. Preliminary R&D on some aspects of the system were also done in Phase 1, and a Research, Development and Test plan was developed for Phase 2. Work in Phase 2 include s the testing and analysis that is required to develop the technology base for a prototype plant. This work includes pilot plant testing at a scale of around 50 MMBtu/hr heat input. The culmination of the Phase 2 effort will be a site-specific design and test plan for a prototype plant. Phase 3 is the construction and testing of this plant.

  15. Device Performance

    SciTech Connect (OSTI)

    Not Available

    2006-06-01T23:59:59.000Z

    In the Device Performance group, within the National Center for Photovoltaic's Measurements and Characterization Division, we measure the performance of PV cells and modules with respect to standard reporting conditions--defined as a reference temperature (25 C), total irradiance (1000 Wm-2), and spectral irradiance distribution (IEC standard 60904-3). Typically, these are ''global'' reference conditions, but we can measure with respect to any reference set. To determine device performance, we conduct two general categories of measurements: spectral responsivity (SR) and current versus voltage (I-V). We usually perform these measurements using standard procedures, but we develop new procedures when required by new technologies. We also serve as an independent facility for verifying device performance for the entire PV community. We help the PV community solve its special measurement problems, giving advice on solar simulation, instrumentation for I-V measurements, reference cells, measurement procedures, and anomalous results. And we collaborate with researchers to analyze devices and materials.

  16. 1michigan state university brand STandardS BRAND STANDARDS

    E-Print Network [OSTI]

    1michigan state university brand STandardS BRAND STANDARDS VERSION 4, APRIL 30, 2012 #12;2michigan state university brand STandardS TABLE OF CONTENTS 3 brand baSicS 5 The Michigan STaTe UniverSiTy brandUrTher gUidance #12;3michigan state university brand STandardS 1. BrANd BASICS 1a whaT iS a brand? We build

  17. APPLIANCE STANDARDS

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of ScienceandMesa del(ANL-IN-03-032)8Li (59AJ76) (See theDoctoral20ALSNewstt^APPLIANCE STANDARDS How they

  18. Standard-E hydrogen monitoring system shop acceptance test procedure

    SciTech Connect (OSTI)

    Schneider, T.C.

    1997-10-02T23:59:59.000Z

    The purpose of this report is to document that the Standard-E Hydrogen Monitoring Systems (SHMS-E), fabricated by Mid-Columbia Engineering (MCE) for installation on the Waste Tank Farms in the Hanford 200 Areas, are constructed as intended by the design. The ATP performance will verify proper system fabrication.

  19. Commercial Building Codes and Standards

    Broader source: Energy.gov [DOE]

    Once an energy-efficient technology or practice is widely available in the market, it can become the baseline of performance through building energy codes and equipment standards. The Building...

  20. Options for Generating Steam Efficiently

    E-Print Network [OSTI]

    Ganapathy, V.

    This paper describes how plant engineers can efficiently generate steam when there are steam generators and Heat Recovery Steam Generators in their plant. The process consists of understanding the performance characteristics of the various equipment...

  1. Content Literacy Tied to the New Standards

    E-Print Network [OSTI]

    Stuart, Steven J.

    Content Literacy Tied to the New Standards Tom Peters, Ed.D. SC Coalition for Mathematics & Science as they relate to the Common Core State Standards for Mathematics and the Next Generation Science Standards*. #12 in extended discussion about those ideas. Framework for K-12 Science pg 76 #12;So What Does this mean in K-12

  2. UNIVERSITY STANDARDS AND REGULATIONS

    E-Print Network [OSTI]

    Royer, Dana

    2014­2015 UNIVERSITY STANDARDS AND REGULATIONS #12;Wesleyan University does not discriminate STANDARDS OF CONDUCT

  3. UNIVERSITY STANDARDS AND REGULATIONS

    E-Print Network [OSTI]

    Royer, Dana

    2013­2014 UNIVERSITY STANDARDS AND REGULATIONS #12;Wesleyan University does not discriminate STANDARDS OF CONDUCT

  4. 2011 DoD High Performance Computing Modernization Program Users Group Conference A Web-based High-Throughput Tool for Next-Generation Sequence Annotation

    E-Print Network [OSTI]

    320 2011 DoD High Performance Computing Modernization Program Users Group Conference A Web deployed on the Mana Linux cluster at the Maui High Performance Computing Center. The two components

  5. December 2006 Standards Forum and Standards Actions

    Energy Savers [EERE]

    -9 Cancellations in Progress - 0 Inside This Issue Visit the Technical Standards Program Web Site at http:tis.eh.doe.govtechstds December 2006 The Standards Forum and Standards...

  6. The Standard Cosmological Model and CMB Anisotropies

    E-Print Network [OSTI]

    James G. Bartlett

    1999-03-17T23:59:59.000Z

    This is a course on cosmic microwave background (CMB) anisotropies in the standard cosmological model, designed for beginning graduate students and advanced undergraduates. ``Standard cosmological model'' in this context means a Universe dominated by some form of cold dark matter (CDM) with adiabatic perturbations generated at some initial epoch, e.g., Inflation, and left to evolve under gravity alone (which distinguishes it from defect models). The course is primarily theoretical and concerned with the physics of CMB anisotropies in this context and their relation to structure formation. Brief presentations of the uniform Big Bang model and of the observed large--scale structure of the Universe are given. The bulk of the course then focuses on the evolution of small perturbations to the uniform model and on the generation of temperature anisotropies in the CMB. The theoretical development is performed in the (pseudo--)Newtonian gauge because it aids intuitive understanding by providing a quick reference to classical (Newtonian) concepts. The fundamental goal of the course is not to arrive at a highly exact nor exhaustive calculation of the anisotropies, but rather to a good understanding of the basic physics that goes into such calculations.

  7. Standard 90. 1's ENVSTD: Both a compliance program and an envelope design tool

    SciTech Connect (OSTI)

    Crawley, D.B.; Boulin, J.J.

    1989-12-01T23:59:59.000Z

    Since 1982, ASHRAE and the US Department of Energy have worked together to update ANSI/ASHRAE/IES Standard 90A-1980, Energy Conservation in Building Design.'' The new standard, ASHRAE/IES Standard 90.1-1989, Energy-Efficient Design of New Buildings Except Low-Rise Residential Buildings,'' is substantially changed in form and concept from Standard 90A-1980, especially in how it deals with exterior envelopes. In the new standard, designers can use either of two methods -- prescriptive or system performance -- to comply with building envelope requirements. Under the prescriptive method, requirements are listed in tabular form and designers must demonstrate compliance with each individual requirement. In the system performance method, designers generate the requirements for their specific building using a set of equations. The equations establish limits on permissible heating and cooling coil loads based on the local climate and the internal loads in the exterior zones of the building. A personal computer program, ENVSTD (ENVelope STanDard), has been written to simplify compliance with the system performance path of the standard. The program can also be used to evaluate the impact of varying envelope characteristics on building heating and cooling coil loads in specific locations. This paper provides examples of the impacts that the standard's envelope requirements have on envelope design. Use of the ENVSTD program as a design tool to determine the heating and cooling load impacts of various envelope strategies is also demonstrated. 7 refs., 12 figs.

  8. Hardness Standardization Our objective is to standardize and improve hardness measurement

    E-Print Network [OSTI]

    by Standard Development Organizations (SDOs) such as ASTM International and the International Organization and Measures (BIPM) during the development of international test method standards, by those performing hardnessHardness Standardization METALS Our objective is to standardize and improve hardness measurement

  9. Why Do States Adopt Renewable Portfolio Standards?: An Empirical Investigation

    E-Print Network [OSTI]

    Lyon, Thomas P.

    131 Why Do States Adopt Renewable Portfolio Standards?: An Empirical Investigation Thomas P. Lyon* and Haitao Yin** Renewable portfolio standards (RPSs) for electricity generation are politically popularU.S.stategovernments of Renewable Portfolio Standards (RPSs) as a policy tool for promoting renewable electricity generation. An RPS

  10. National Green Building Standard Analysis

    SciTech Connect (OSTI)

    NAHB Research Center, Upper Marlboro, Maryland

    2012-07-01T23:59:59.000Z

    DOE's Building America Program is a research and development program to improve the energy performance of new and existing homes. The ultimate goal of the Building America Program is to achieve examples of cost-effective, energy efficient solutions for all U.S. climate zones. Periodic maintenance of an ANSI standard by review of the entire document and action to revise or reaffirm it on a schedule not to exceed five years is required by ANSI. In compliance, a consensus group has once again been formed and the National Green Building Standard is currently being reviewed to comply with the periodic maintenance requirement of an ANSI standard.

  11. GAP analysis towards a design qualification standard development for grid-connected photovoltaic inverters.

    SciTech Connect (OSTI)

    Tamizhmani, Govindasamy (Arizona State University, Tempe, AZ); Granata, Jennifer E.; Maracas, George (Arizona State University, Tempe, AZ); Ayyanar, Raja (Arizona State University, Tempe, AZ); Marinella, Matthew; Venkataramanan, Sai Balasubramanian Alampoondi (Arizona State University, Tempe, AZ)

    2011-06-01T23:59:59.000Z

    A dedicated design qualification standard for PV inverters does not exist. Development of a well-accepted design qualification standard, specifically for PV inverters will significantly improve the reliability and performance of inverters. The existing standards for PV inverters such as ANSI/UL 1741 and IEC 62109-1 primarily focus on safety of PV inverters. The IEC 62093 discusses inverter qualification but it includes all the BOS components. There are other general standards for distributed generators including the IEEE 1547 series of standards which cover major concerns like utility integration but they are not dedicated to PV inverters and are not written from a design qualification point of view. In this paper some of the potential requirements for a design qualification standard for PV inverters are addressed. The missing links in existing PV inverter related standards are identified and with the IEC 62093 as a guideline, the possible inclusions in the framework for a dedicated design qualification standard of PV inverter are discussed. Some of the key missing links are related to electric stress tests. Hence, a method to adapt the existing surge withstand test standards for use in design qualification standard of PV inverter is presented.

  12. Seminar on building codes and standards

    SciTech Connect (OSTI)

    Not Available

    1980-01-01T23:59:59.000Z

    A seminar was conducted for state building code officials and state energy officials to discuss the following: status of the states regulatory activities for energy conservation standards for buildings; the development, administration, and enforcement processes for energy conservation standards affecting new construction; lighting and thermal standards for existing buildings; status of the development and implementation of the Title III Program, Building Energy Performance Standards (BEPS); and current status of the State Energy Conservation Program. The welcoming address was given by John Wenning and the keynote address was delivered by John Millhone. Four papers presented were: Building Energy Performance Standards Development, James Binkley; Lighting Standards in Existing Buildings, Dorothy Cronheim; Implementation of BEPS, Archie Twitchell; Sanctions for Building Energy Performance Standards, Sue Sicherman.

  13. Renewable Energy Standard (Nova Scotia, Canada)

    Broader source: Energy.gov [DOE]

    On February 1, 2007, Nova Scotia's new Renewable Energy Standards took effect. By 2013, Nova Scotia will generate at least 18.5% of the Province's electricity through renewable energy -- wind,...

  14. AISI/DOE Technology Roadmap Program: Characterization of Fatigue and Crash Performance of New Generation High Strength Steels for Automotive Applications

    SciTech Connect (OSTI)

    Brenda Yan; Dennis Urban

    2003-04-21T23:59:59.000Z

    A 2-year project (2001-2002) to generate fatigue and high strain data for a new generation of high strength steels (HSS) has been completed in December 2002. The project tested eleven steel grades, including Dual Phase (DP) steels, Transformation-Induced Plasticity (TRIP) steels, Bake Hardenable (BH) steels, and conventional High Strength Low Alloy (HSLA) steels. All of these steels are of great interest in automotive industry due to the potential benefit in weight reduction, improved fuel economy, enhanced crash energy management and total system cost savings. Fatigue behavior includes strain controlled fatigue data notch sensitivity for high strength steels. High strain rate behavior includes stress-strain data for strain rates from 0.001/s to 1000/s, which are considered the important strain rate ranges for crash event. The steels were tested in two phases, seven were tested in Phase 1 and the remaining steels were tested in Phase. In a addition to the fatigue data and high st rain rate data generated for the steels studied in the project, analyses of the testing results revealed that Advanced High Strength Steels (AHSS) exhibit significantly higher fatigue strength and crash energy absorption capability than conventional HSS. TRIP steels exhibit exceptionally better fatigue strength than steels of similar tensile strength but different microstructure, for conditions both with or without notches present

  15. Issues in Purchasing and Maintaining Intrinsic Standards

    SciTech Connect (OSTI)

    PETTIT,RICHARD B.; JAEGER,KLAUS; EHRLICH,CHARLES D.

    2000-09-12T23:59:59.000Z

    Intrinsic standards are widely used in the metrology community because they realize the best level uncertainty for many metrology parameters. For some intrinsic standards, recommended practices have been developed to assist metrologists in the selection of equipment and the development of appropriate procedures in order to realize the intrinsic standard. As with the addition of any new standard, the metrology laboratory should consider the pros and cons relative to their needs before purchasing the standard so that the laboratory obtains the maximum benefit from setting up and maintaining these standards. While the specific issues that need to be addressed depend upon the specific intrinsic standard and the level of realization, general issues that should be considered include ensuring that the intrinsic standard is compatible with the laboratory environment, that the standard is compatible with the current and future workload, and whether additional support standards will be required in order to properly maintain the intrinsic standard. When intrinsic standards are used to realize the best level of uncertainty for a specific metrology parameter, they usually require critical and important maintenance activities. These activities can including training of staff in the system operation, as well as safety procedures; performing periodic characterization measurements to ensure proper system operation; carrying out periodic intercomparisons with similar intrinsic standards so that proper operation is demonstrated; and maintaining control or trend charts of system performance. This paper has summarized many of these important issues and therefore should be beneficial to any laboratory that is considering the purchase of an intrinsic standard.

  16. Microfabricated ion frequency standard

    SciTech Connect (OSTI)

    Schwindt, Peter (Albuquerque, NM); Biedermann, Grant (Albuquerque, NM); Blain, Matthew G. (Albuquerque, NM); Stick, Daniel L. (Albuquerque, NM); Serkland, Darwin K. (Albuquerque, NM); Olsson, III, Roy H. (Albuquerque, NM)

    2010-12-28T23:59:59.000Z

    A microfabricated ion frequency standard (i.e. an ion clock) is disclosed with a permanently-sealed vacuum package containing a source of ytterbium (Yb) ions and an octupole ion trap. The source of Yb ions is a micro-hotplate which generates Yb atoms which are then ionized by a ultraviolet light-emitting diode or a field-emission electron source. The octupole ion trap, which confines the Yb ions, is formed from suspended electrodes on a number of stacked-up substrates. A microwave source excites a ground-state transition frequency of the Yb ions, with a frequency-doubled vertical-external-cavity laser (VECSEL) then exciting the Yb ions up to an excited state to produce fluorescent light which is used to tune the microwave source to the ground-state transition frequency, with the microwave source providing a precise frequency output for the ion clock.

  17. Non standard neutrino interactions

    E-Print Network [OSTI]

    Miranda, O G

    2015-01-01T23:59:59.000Z

    Neutrino oscillations have become well-known phenomenon; the measurements of neutrino mixing angles and mass squared differences are continuously improving. Future oscillation experiments will eventually determine the remaining unknown neutrino parameters, namely, the mass ordering, normal or inverted, and the CP-violating phase. On the other hand, the absolute mass scale of neutrinos could be probed by cosmological observations, single beta decay as well as by neutrinoless double beta decay experiments. Furthermore, the last one may shed light on the nature of neutrinos, Dirac or Majorana, by measuring the effective Majorana mass of neutrinos. However, the neutrino mass generation mechanism remains unknown. A well-motivated phenomenological approach to search for new physics, in the neutrino sector, is that of non-standard interactions. In this short review, the current constraints in this picture, as well as the perspectives from future experiments, are discussed.

  18. Distributional and Efficiency Impacts of Clean and Renewable Energy Standards

    E-Print Network [OSTI]

    supply and demand, including renewable energy resources and generating technologies, while representingDistributional and Efficiency Impacts of Clean and Renewable Energy Standards for Electricity on recycled paper #12;Distributional and Efficiency Impacts of Clean and Renewable Energy Standards

  19. Effect of building airtightness and fan size on the performance of mechanical ventilation systems in new U.S. houses: a critique of ASHRAE standard 62.2-2003

    E-Print Network [OSTI]

    Roberson, J.

    2004-01-01T23:59:59.000Z

    Install Residential Ventilation Systems. The Healthy HouseMechanical Ventilation Systems. Canadian StandardsCode: Whole House Ventilation Systems Research Report. 39

  20. Steam generator tube rupture study

    E-Print Network [OSTI]

    Free, Scott Thomas

    1986-01-01T23:59:59.000Z

    This report describes our investigation of steam generator behavior during a postulated tube rupture accident. Our study was performed using the steam generator, thermal-hydraulic analysis code THERMIT-UTSG. The purpose ...

  1. Communication Standards and Recommendations

    E-Print Network [OSTI]

    Communication Standards and Recommendations Introduction & Purpose 3 Standards & Recommendations Communication 4 Training 10 Evaluation 11 PMO Workgroup Participation 12 Staffing 12 Communications-related Tracking Grantee Portal Standards and Recommendations 13

  2. August 2007 Standards Actions

    Broader source: Energy.gov (indexed) [DOE]

    August 2007 1.5 DOE Technical Standards Published No entries were received in August 2007 2.0 Non-Government Standards Actions 2.1 American National Standards Institute (ANSI)...

  3. July 2007 Standards Actions

    Broader source: Energy.gov (indexed) [DOE]

    in June 2007 1.5 DOE Technical Standards Published No entries were received in June 2007 2.0 Non-Government Standards Actions 2.1 American National Standards Institute (ANSI)...

  4. October 2006 Standards Actions

    Broader source: Energy.gov (indexed) [DOE]

    Project No. SAFT-0109 Continued on next page Standards Actions Page 2 October 2006 2.0 NON-GOVERNMENT STANDARDS ACTIONS 2.1 American National Standards Institute American...

  5. July 2006 Standards Actions

    Broader source: Energy.gov (indexed) [DOE]

    were received in June 2006. Continued on next page Standards Actions Page 2 July 2005 2.0 Non-Government Standards Actions 2.1 American National Standards Institute (ANSI)...

  6. Energy Efficiency Product Standards

    Broader source: Energy.gov [DOE]

    '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of...

  7. Renewable Portfolio Standard

    Broader source: Energy.gov [DOE]

    In 2007, Minnesota legislation modified the state's existing non-mandated renewable energy objective, creating a mandatory renewable portfolio standard (RPS) called the Renewable Energy Standard ...

  8. November 2006 Standards Actions

    Broader source: Energy.gov (indexed) [DOE]

    Standards Actions 2 American National Standards Institute (ANSI) 2 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society...

  9. October 2007 Standards Actions

    Broader source: Energy.gov (indexed) [DOE]

    Standards Actions 1 American National Standards Institute (ANSI) 1 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society...

  10. May 2008 Standards Actions

    Broader source: Energy.gov (indexed) [DOE]

    Standards Actions 2 American National Standards Institute (ANSI) 2 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society...

  11. May 2006 Standards Actions

    Broader source: Energy.gov (indexed) [DOE]

    Standards Actions 1 American National Standards Institute (ANSI) 1 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society...

  12. February 2001 Standards Actions

    Broader source: Energy.gov (indexed) [DOE]

    Technical Standards Program Document Status Visit the Technical Standards Program Web Site: http:tis.eh.doe.govtechstds Activity Summary In Conversion - 4 In Preparation...

  13. ASME PTC 46 -- Acceptance test code for overall plant performance

    SciTech Connect (OSTI)

    Friedman, J.R. [Siemens-Westinghouse Power Corp., Orlando, FL (United States); Yost, J.G. [Sargent and Lundy, Chicago, IL (United States)

    1999-11-01T23:59:59.000Z

    ASME published PTC 46 in 1996 after five years of development. PTC 46 is the first industry standard providing explicit procedures for conducting acceptance tests to determine the overall thermal performance and output of power generating units. It is applicable to any heat cycle power generating unit. This survey paper provides an overview of PTC 46 and discusses how PTC 46 can be used for acceptance testing of new combined cycle and fossil steam power generating units. Several technical papers have been previously presented that provide more detailed information and discussion on the use of PTC 46 in acceptance testing.

  14. Technical Standards Program

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2011-02-23T23:59:59.000Z

    The Order promotes DOE's use of Voluntary Consensus Standards (VCS) as the primary method for application of technical standards and establishes and manages the DOE Technical Standards Program (TSP) including technical standards development, information, activities, issues, and interactions. Admin Chg 1 dated 3-12-13.

  15. Technical Standards Program

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1999-11-19T23:59:59.000Z

    The Technical Standards Program (TSP) promotes the use of voluntary consensus standards by the Department of Energy (DOE), provides DOE with the means to develop needed technical standards, and manages overall technical standards information, activities, issues, and interactions. Cancels DOE O 1300.2A. Canceled by DOE O 252.1A

  16. Standard 90, the planning

    SciTech Connect (OSTI)

    Not Available

    1985-10-01T23:59:59.000Z

    In order to understand the current proposed ANS/ASHRAE/IES Standard 90.1 Energy Efficient Design of New Non-Residential Buildings and New High-Rise, Residential Buildings, this article offers background on the initial Standard, the organization of the Standard committee, and the objectives established for the proposed Standard 90.1.

  17. Generating Squeezed States of Nanomechanical Resonator

    E-Print Network [OSTI]

    Wen Yi Huo; Gui Lu Long

    2007-06-15T23:59:59.000Z

    We propose a scheme for generating squeezed states in solid state circuits consisting of a nanomechanical resonator (NMR), a superconducting Cooper-pair box (CPB) and a superconducting transmission line resonator (STLR). The nonlinear interaction between the NMR and the STLR can be implemented by setting the external biased flux of the CPB at certain values. The interaction Hamiltonian between the NMR and the STLR is derived by performing Fr$\\rm\\ddot o$hlich transformation on the total Hamiltonian of the combined system. Just by adiabatically keeping the CPB at the ground state, we get the standard parametric down-conversion Hamiltonian. The CPB plays the role of ``nonlinear media", and the squeezed states of the NMR can be easily generated in a manner similar to the three-wave mixing in quantum optics. This is the three-wave mixing in a solid-state circuit.

  18. Performance Metrics for Commercial Buildings

    SciTech Connect (OSTI)

    Fowler, Kimberly M.; Wang, Na; Romero, Rachel L.; Deru, Michael P.

    2010-09-30T23:59:59.000Z

    Commercial building owners and operators have requested a standard set of key performance metrics to provide a systematic way to evaluate the performance of their buildings. The performance metrics included in this document provide standard metrics for the energy, water, operations and maintenance, indoor environmental quality, purchasing, waste and recycling and transportation impact of their building. The metrics can be used for comparative performance analysis between existing buildings and industry standards to clarify the impact of sustainably designed and operated buildings.

  19. Impacts of China's Current Appliance Standards and Labeling Program to 2020

    E-Print Network [OSTI]

    Fridley, David; Aden, Nathaniel; Zhou, Nan; Lin, Jiang

    2007-01-01T23:59:59.000Z

    coal-fired electricity generation in China, appliance standards and labeling programs also help to mitigate air-pollution

  20. Technical Standards,DOE Standards and Corresponding Directives...

    Broader source: Energy.gov (indexed) [DOE]

    February 2, 2002 DOE Standards and Corresponding Directives Crosswalk DOE Standards and Corresponding Directives Crosswalk table Technical Standards,DOE Standards and Corresponding...

  1. Development of a high-performance coal-fired power generating system with pyrolysis gas and char-fired high-temperature furnace (HITAF): Volume 3. Final report

    SciTech Connect (OSTI)

    NONE

    1996-05-01T23:59:59.000Z

    Testing of an atmospheric circulating bed pyrolyzer was done at Southern Illinois University. A variety of experiments have been conducted in a laboratory scale pyrolyzer with coal input flow rates from 2 to 6 lb/h. three feed coal particle sizes, corresponding to a nominal -40 mesh, -30 mesh and -18 mesh were used. The limestone used in the tests was a Genstar limestone. Parameters investigated in the tests include the influence of superficial velocity, temperature and coal-air mass ratios. Char particle size distributions under various test conditions have been measured and the char composition determined. Fuel gas composition, yields and heating values have been investigated. Char morphology has been studied using scanning electron microscopy. Char reactivity for selected samples has been measures, and the influence of feed coal size, bed temperature and superficial velocity has been determined. Material balance calculations have been performed and found to be in very good agreement. Energy audit calculations for the process have been made to investigate the flow of energy and to estimate the losses during the process. Full details of the data, results obtained and conclusions drawn are presented.

  2. Construction of Blaze at the University of Illinois at Chicago: A Shared, High-Performance, Visual Computer for Next-Generation Cyberinfrastructure-Accelerated Scientific, Engineering, Medical and Public Policy Research

    SciTech Connect (OSTI)

    Brown, Maxine D. [Acting Director, EVL; Leigh, Jason [PI

    2014-02-17T23:59:59.000Z

    The Blaze high-performance visual computing system serves the high-performance computing research and education needs of University of Illinois at Chicago (UIC). Blaze consists of a state-of-the-art, networked, computer cluster and ultra-high-resolution visualization system called CAVE2(TM) that is currently not available anywhere in Illinois. This system is connected via a high-speed 100-Gigabit network to the State of Illinois' I-WIRE optical network, as well as to national and international high speed networks, such as the Internet2, and the Global Lambda Integrated Facility. This enables Blaze to serve as an on-ramp to national cyberinfrastructure, such as the National Science Foundation’s Blue Waters petascale computer at the National Center for Supercomputing Applications at the University of Illinois at Chicago and the Department of Energy’s Argonne Leadership Computing Facility (ALCF) at Argonne National Laboratory. DOE award # DE-SC005067, leveraged with NSF award #CNS-0959053 for “Development of the Next-Generation CAVE Virtual Environment (NG-CAVE),” enabled us to create a first-of-its-kind high-performance visual computing system. The UIC Electronic Visualization Laboratory (EVL) worked with two U.S. companies to advance their commercial products and maintain U.S. leadership in the global information technology economy. New applications are being enabled with the CAVE2/Blaze visual computing system that is advancing scientific research and education in the U.S. and globally, and help train the next-generation workforce.

  3. Peer Review of NRC Standardized Plant Analysis Risk Models

    SciTech Connect (OSTI)

    Anthony Koonce; James Knudsen; Robert Buell

    2011-03-01T23:59:59.000Z

    The Nuclear Regulatory Commission (NRC) Standardized Plant Analysis Risk (SPAR) Models underwent a Peer Review using ASME PRA standard (Addendum C) as endorsed by NRC in Regulatory Guide (RG) 1.200. The review was performed by a mix of industry probabilistic risk analysis (PRA) experts and NRC PRA experts. Representative SPAR models, one PWR and one BWR, were reviewed against Capability Category I of the ASME PRA standard. Capability Category I was selected as the basis for review due to the specific uses/applications of the SPAR models. The BWR SPAR model was reviewed against 331 ASME PRA Standard Supporting Requirements; however, based on the Capability Category I level of review and the absence of internal flooding and containment performance (LERF) logic only 216 requirements were determined to be applicable. Based on the review, the BWR SPAR model met 139 of the 216 supporting requirements. The review also generated 200 findings or suggestions. Of these 200 findings and suggestions 142 were findings and 58 were suggestions. The PWR SPAR model was also evaluated against the same 331 ASME PRA Standard Supporting Requirements. Of these requirements only 215 were deemed appropriate for the review (for the same reason as noted for the BWR). The PWR review determined that 125 of the 215 supporting requirements met Capability Category I or greater. The review identified 101 findings or suggestions (76 findings and 25 suggestions). These findings or suggestions were developed to identify areas where SPAR models could be enhanced. A process to prioritize and incorporate the findings/suggestions supporting requirements into the SPAR models is being developed. The prioritization process focuses on those findings that will enhance the accuracy, completeness and usability of the SPAR models.

  4. Evaluation of waveform digitizer systems and components in accordance with IEEE waveform digitizer standards

    SciTech Connect (OSTI)

    Green, P.J.

    1989-01-01T23:59:59.000Z

    Our division is charged with instrumentation development in support of underground testing. We find it necessary to be able to evaluate the performance of waveform digitizing systems with sampling rates from a few kilohertz to more than a gigahertz. We have been developing an integrated system which can provide quantitative results on the performance of systems and subsystems. Here we describe a system which is controlled by a Microvax II with instrumentation control through the IEEE-488 buss. The evaluation procedures are aimed at being consistent with a new Trial Waveform Digitizer Standard generated by the Waveform Measurements and Analysis committee appointed by the Instrumentation and Measurement Society of IEEE. This standard has been recently accepted by the IEEE and will be published in the next few months. Attention is given to the accurate measurement of effective-bit performance and differential nonlinearity of waveform digitizers. 3 refs., 14 figs.

  5. April 2007 Standards Actions

    Broader source: Energy.gov (indexed) [DOE]

    and Injury Surveillance Program Guidelines, 03222007; DOE-STD-1190-2007, OCSH-0005 2.0 Non-Government Standards Actions 2.1 American National Standards Institute (ANSI)...

  6. Puerto Rico- Interconnection Standards

    Broader source: Energy.gov [DOE]

    In 2007, the Autoridad de Energía Electrica de Puerto Rico (PREPA*) adopted interconnection standards based on the standard contained in the federal Energy Policy Act of 2005. PREPA promulgated...

  7. Developments to Supplant CAMAC with Industry Standard Technology at NSTX

    SciTech Connect (OSTI)

    Sichta, P.; Dong, J.; Marsala, R.; Oliaro, G.; Wertenbaker, J.

    2003-07-31T23:59:59.000Z

    NSTX, like other research programs, is facing an inevitable crisis due to end-of-life issues for its 20-year-old CAMAC instrumentation. In many cases replacement components are not available, effectively rendering a CAMAC module unusable after a failure. The proliferation of high-performance, reliable, low-cost commodity computing hardware and software based on industry standard technology can provide the basis for a new generation of instrumentation. At NSTX, there have been several advances towards developing a PCI-based model for data acquisition and control systems. New hardware developments include a High Performance Signal Conditioning board and an FPGA-based Multifunction Timing System. Extensible software interfaces have been developed to integrate these boards into the NSTX computing environment. This paper will illustrate these developments and how they could be used to benefit collaborative fusion research.

  8. Low Carbon Fuel Standards

    E-Print Network [OSTI]

    Sperling, Dan; Yeh, Sonia

    2009-01-01T23:59:59.000Z

    flexible-fuel cars, launched the Advanced Battery Consortium and the Partnership for a New Generation

  9. Meeting Residential Ventilation Standards

    E-Print Network [OSTI]

    ventilation standards, including American Society of Heating, Refrigerating, and Air-conditioning EngineersLBNL 4591E Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems (ASHRAE) Standard 62.2, specify continuous operation of a defined mechanical ventilation system to provide

  10. Graph Generator Survey

    SciTech Connect (OSTI)

    Lothian, Josh [ORNL; Powers, Sarah S [ORNL; Sullivan, Blair D [ORNL; Baker, Matthew B [ORNL; Schrock, Jonathan [ORNL; Poole, Stephen W [ORNL

    2013-12-01T23:59:59.000Z

    The benchmarking effort within the Extreme Scale Systems Center at Oak Ridge National Laboratory seeks to provide High Performance Computing benchmarks and test suites of interest to the DoD sponsor. The work described in this report is a part of the effort focusing on graph generation. A previously developed benchmark, SystemBurn, allowed the emulation of dierent application behavior profiles within a single framework. To complement this effort, similar capabilities are desired for graph-centric problems. This report examines existing synthetic graph generator implementations in preparation for further study on the properties of their generated synthetic graphs.

  11. Local control of reactive power by distributed photovoltaic generators

    SciTech Connect (OSTI)

    Chertkov, Michael [Los Alamos National Laboratory; Turitsyn, Konstantin [Los Alamos National Laboratory; Sulc, Petr [Los Alamos National Laboratory; Backhaus, Scott [Los Alamos National Laboratory

    2010-01-01T23:59:59.000Z

    High penetration levels of distributed photovoltaic (PV) generation on an electrical distribution circuit may severely degrade power quality due to voltage sags and swells caused by rapidly varying PV generation during cloud transients coupled with the slow response of existing utility compensation and regulation equipment. Although not permitted under current standards for interconnection of distributed generation, fast-reacting, VAR-capable PV inverters may provide the necessary reactive power injection or consumption to maintain voltage regulation under difficult transient conditions. As side benefit, the control of reactive power injection at each PV inverter provides an opportunity and a new tool for distribution utilities to optimize the performance of distribution circuits, e.g. by minimizing thermal losses. We suggest a local control scheme that dispatches reactive power from each PV inverter based on local instantaneous measurements of the real and reactive components of the consumed power and the real power generated by the PVs. Using one adjustable parameter per circuit, we balance the requirements on power quality and desire to minimize thermal losses. Numerical analysis of two exemplary systems, with comparable total PV generation albeit a different spatial distribution, show how to adjust the optimization parameter depending on the goal. Overall, this local scheme shows excellent performance; it's capable of guaranteeing acceptable power quality and achieving significant saving in thermal losses in various situations even when the renewable generation in excess of the circuit own load, i.e. feeding power back to the higher-level system.

  12. Laboratory Performance Testing of Residential Window Air Conditioners

    SciTech Connect (OSTI)

    Winkler, J.; Booten, C.; Christensen, D.; Tomerlin, J.

    2013-03-01T23:59:59.000Z

    Window air conditioners are the dominant cooling product for residences, in terms of annual unit sales. They are inexpensive, portable and can be installed by the owner. For this reason, they are an attractive solution for supplemental cooling, for retrofitting air conditioning into a home which lacks ductwork, and for renters. Window air conditioners for sale in the United States are required to meet very modest minimum efficiency standards. Four window air conditioners' performance were tested in the Advanced HVAC Systems Laboratory on NREL's campus in Golden, CO. In order to separate and study the refrigerant system's performance, the unit's internal leakage pathways, the unit's fanforced ventilation, and the leakage around the unit resulting from installation in a window, a series of tests were devised that focused on each aspect of the unit's performance. These tests were designed to develop a detailed performance map to determine whole-house performance in different climates. Even though the test regimen deviated thoroughly from the industry-standard ratings test, the results permit simple calculation of an estimated rating for both capacity and efficiency that would result from a standard ratings test. Using this calculation method, it was found that the three new air conditioners' measured performance was consistent with their ratings. This method also permits calculation of equivalent SEER for the test articles. Performance datasets were developed across a broad range of indoor and outdoor operating conditions, and used them to generate performance maps.

  13. Thermoelectric Generator Performance for Passenger Vehicles

    Broader source: Energy.gov (indexed) [DOE]

    modeling and architecture evaluation * Phase 2: Subsystem design, build and bench test * Phase 3: System integration. Planar configuration TEG with primary HEX and secondary...

  14. High Performance, Low Cost Hydrogen Generation from

    E-Print Network [OSTI]

    Alternate deposition techniques and engineered nanostructures Supplier qualification, near term cost Qualification · Task 7.0: H2A Model Cost Analysis ­ Input design parameters ­ Assess impact of changes #12% 5 Bipolar Plate Manufacturing Development 06/30/13 0% 6 Bipolar Plate Manufacturing Qualification 09

  15. DEMONSTRATION OF THE DOE INTERIM ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL RESIDENTIAL BUILDINGS: EXECUTIVE SUMMARY

    SciTech Connect (OSTI)

    Lee, A. D.; Baechler, M / C.; Di Massa, F. V.; Lucas, R. G.; Shankle, D. L.

    1992-01-01T23:59:59.000Z

    In accordance with federal legislation, the U.S. Department of Energy (DOE) bas conducted a project to demonstrate use of its Interim Energy Conservation Standards for New Federal Residential Buildings. The demonstration is the second step in a three-step process: development of interim standards, demonstration of the interim standards, and development of final standards. Pacific Northwest Laboratory (PNL) collected information from the demonstration project and prepared this report under a contract with DOE. The purpose of the standards is to improve the energy efficiency of federal housing and increase the use of nondepletable energy sources. In accordance with the legislation, the standards were to be performance-based rather than prescribing specific energy conservation measures. The standards use a computer software program called COSTSAFR which individualizes the standards based on climate, housing type, and fuel costs. The standards generate minimum energy-efficiency requirements by applying the life-cycle cost methodology developed for federal projects, For the demonstration, the DOE chose live federal agency housing projects: four military housing projects and one project for the Department of Health and Human Services. DOE and PNL worked with agency housing procurement officials and designers/architects to hypothetically apply the interim standards to each housing project. PNL conducted extensive interviews with the federal agencies and design contractors to determine what impacts the standards would have on the existing agency procurement process as well as on designers. Overall, PNL found that the interim standards met the basic intent of the law. Specific actions were identified, however, that DOE could take to improve the standards and encourage the agencies to implement them. Agency personnel and designers expressed similar concerns about the standards: the minimum efficiency levels established by the standards were lower than expected and the standards did not provide an easy way to incorporate new energy-efficient and renewable resource tec.:hnolog:ies like solar heating systems. Agency personnel said the standards would fit into current procurement procedures with no big changes or cost increases, Many said the standards would decrease the time and effort they now spend to establish energy-efficiency requirements and to confirm that proposed designs comply with those requirements. Agency personnel praised the software and documentation for being easy to use and providing energy-efficiency requirements in energy dollars. Housing designers agreed that the DOE standards were easy to use to determine that their designs meet energy-efficiency goals. Many felt the information provided by the standards could be useful in the design process. Based on the demonstration, PNL recommends establishing task forces that will actively involve agency personnel and others in future revisions and development of the final standards. PNL also recommends that DOE and federal agencies investigate the use of market fuel and energy prices in the standards, rather than the prices paid by the agencies, to better reflect actual costs. A number of recommendations are made for improving communications between DOE and the users of the standards and for enhancing tools to implement the standards. Several recommendations are made for increasing the number of renewable resources that are included in the standards. Finally, PNL recommends ongoing monitoring activities to continue to identify ways in which the standards can be improved.

  16. Thermoelectric Generators 1. Thermoelectric generator

    E-Print Network [OSTI]

    Lee, Ho Sung

    1 Thermoelectric Generators HoSung Lee 1. Thermoelectric generator 1.1 Basic Equations In 1821 effects are called the thermoelectric effects. The mechanisms of thermoelectricity were not understood. Cold Hot I - -- - - - - -- Figure 1 Electron concentration in a thermoelectric material. #12;2 A large

  17. CONVERSION OF DOE TECHNICAL STANDARDS TO NON-GOVERNMENT STANDARDS

    Broader source: Energy.gov [DOE]

    PurposeThis procedure provides guidance on the conversion of DOE Technical Standards to Voluntary Consensus Standards (VCSs), also referred to as non-Government standards

  18. National Incident Management System (NIMS) Standards Review Panel Workshop Summary Report

    SciTech Connect (OSTI)

    Stenner, Robert D.; Kirk, Jennifer L.; Stanton, James R.; Shebell, Peter; Schwartz, Deborah S.; Judd, Kathleen S.; Gelston, Gariann M.

    2006-02-07T23:59:59.000Z

    The importance and need for full compliant implementation of NIMS nationwide was clearly demonstrated during the Hurricane Katrina event, which was clearly expressed in Secretary Chertoff's October 4, 2005 letter addressed to the State's governors. It states, ''Hurricane Katrina was a stark reminder of how critical it is for our nation to approach incident management in a coordinated, consistent, and efficient manner. We must be able to come together, at all levels of government, to prevent, prepare for, respond to, and recover from any emergency or disaster. Our operations must be seamless and based on common incident management doctrine, because the challenges we face as a nation are far greater than capabilities of any one jurisdiction.'' The NIMS is a system/architecture for organizing response on a ''national'' level. It incorporations ICS as a main component of that structure (i.e., it institutionalizes ICS in NIMS). In a paper published on the NIMS Website, the following statements were made: ''NIMS represents a core set of doctrine, principles, terminology, and organizational processes to enable effective, efficient and collaborative incident management at all levels. To provide the framework for interoperability and compatibility, the NIMS is based on a balance between flexibility and standardization.'' Thus the NIC is challenged with the need to adopt quality SDO generated standards to support NIMS compliance, but in doing so maintain the flexibility necessary so that response operations can be tailored for the specific jurisdictional and geographical needs across the nation. In support of this large and complex challenge facing the NIC, the Pacific Northwest National Laboratory (PNNL) was asked to provide technical support to the NIC, through their DHS Science and Technology ? Standards Portfolio Contract, to help identify, review, and develop key standards for NIMS compliance. Upon examining the challenge, the following general process appears to be a reasonable approach for identifying and establishing existing standards that would be applicable to NIMS compliance. The suggested generalized steps to establishing existing SDO generated standards for NIMS compliance are: (1) establish search criteria from the NIMS and its support documents, (2) search SDO databases to identify key existing nationally and/or internationally recognized standards that have potential application to NIMS compliance needs, (3) review the identified standards against the specific component needs of the NIMS, (4) identify the pertinent aspects/components of those identified standards that clearly address specific NIMS compliance needs, (5) establish a process to adopt the pertinent standards, which includes the generation of formalized FEMA Guidance that identifies the specific NIMS component compliance needs addressed in the respective standard, (6) develop performance criteria for which to measure compliance with the identified NIMS components addressed by the respective adopted standard, and (7) adopt the standard, publish the guidance and performance criteria, and incorporate it into routine FEMA/NIC NIMS management operations. This review process will also help identify real gaps in standards for which new NIMS specific standards should be developed. To jump start this process and hopefully identify some key ''low hanging fruit'' standards the NIC could use to begin such a process, a panel of first-responder experts (familiar with the current standards of common use in the first-responder community) from various response disciplines was formed and a workshop held. The workshop included a pre-workshop information gathering process. This report discusses the workshop and its findings in detail.

  19. Local Control of Reactive Power by Distributed Photovoltaic Generators

    E-Print Network [OSTI]

    Turitsyn, Konstantin S; Backhaus, Scott; Chertkov, Misha

    2010-01-01T23:59:59.000Z

    High penetration levels of distributed photovoltaic (PV) generation on an electrical distribution circuit may severely degrade power quality due to voltage sags and swells caused by rapidly varying PV generation during cloud transients coupled with the slow response of existing utility compensation and regulation equipment. Although not permitted under current standards for interconnection of distributed generation, fast-reacting, VAR-capable PV inverters may provide the necessary reactive power injection or consumption to maintain voltage regulation under difficult transient conditions. As side benefit, the control of reactive power injection at each PV inverter provides an opportunity and a new tool for distribution utilities to optimize the performance of distribution circuits, e.g. by minimizing thermal losses. We suggest a local control scheme that dispatches reactive power from each PV inverter based on local instantaneous measurements of the real and reactive components of the consumed power and the re...

  20. Options for Control of Reactive Power by Distributed Photovoltaic Generators

    E-Print Network [OSTI]

    Sulc, Petr; Backhaus, Scott; Chertkov, Michael

    2010-01-01T23:59:59.000Z

    High penetration levels of distributed photovoltaic(PV) generation on an electrical distribution circuit present several challenges and opportunities for distribution utilities. Rapidly varying irradiance conditions may cause voltage sags and swells that cannot be compensated by slowly responding utility equipment resulting in a degradation of power quality. Although not permitted under current standards for interconnection of distributed generation, fast-reacting, VAR-capable PV inverters may provide the necessary reactive power injection or consumption to maintain voltage regulation under difficult transient conditions. As side benefit, the control of reactive power injection at each PV inverter provides an opportunity and a new tool for distribution utilities to optimize the performance of distribution circuits, e.g. by minimizing thermal losses. We discuss and compare via simulation various design options for control systems to manage the reactive power generated by these inverters. An important design de...

  1. ORISE: Standards development

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of industry standards that provide guidance and support to decontamination and decommissioning projects across the United States. Because of our extensive experience...

  2. The Standard Model

    ScienceCinema (OSTI)

    Lincoln, Don

    2014-08-12T23:59:59.000Z

    Fermilab scientist Don Lincoln describes the Standard Model of particle physics, covering both the particles that make up the subatomic realm and the forces that govern them.

  3. Renewable Energy Standard

    Broader source: Energy.gov [DOE]

    Rhode Island's Renewable Energy Standard (RES), established in June 2004, requires the state's retail electricity providers -- including non-regulated power producers and distribution companies --...

  4. Energy Conservation Standards Activities

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Report to Congress August 2014 United States Department of Energy Washington, DC 20585 Energy Conservation Standards Activities Report to Congress | Page i Message from the...

  5. Standard Subject Classification System

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1979-08-14T23:59:59.000Z

    The order establishes the DOE Standard Subject Classification System for classifying documents and records by subject, including correspondence, directives, and forms.Cancels DOE O 0000.1.

  6. Groundwater Quality Standards (Nebraska)

    Broader source: Energy.gov [DOE]

    These regulations, promulgated by the Department of Environmental Quality, contain groundwater quality standards and classifications, regulations for point sources, and provisions for remedial action.

  7. February 2008 Standards Actions

    Broader source: Energy.gov (indexed) [DOE]

    2 American National Standards Institute (ANSI) 2 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society (ANS) 2 National Fire Protection...

  8. November 2007 Standards Actions

    Broader source: Energy.gov (indexed) [DOE]

    1 American National Standards Institute (ANSI) 1 American Society of Mechanical Engineers (ASME) 2 ASTM International 2 American Nuclear Society (ANS) 2 National Fire Protection...

  9. National Certification Standard

    Broader source: Energy.gov (indexed) [DOE]

    Certification Standard for the Geothermal Heat Pump Industry Principal Investigator John Kelly Geothermal Heat Pump Consortium GSHP Demonstration Projects May 18, 2010 This...

  10. Columbia- Renewables Portfolio Standard

    Broader source: Energy.gov [DOE]

    In November 2004, voters in Columbia, Missouri approved a proposal to adopt a local renewables portfolio standard (RPS).* The initiative requires the city's municipal utility, Columbia Water and...

  11. Standards Actions, October 2000

    Broader source: Energy.gov (indexed) [DOE]

    61326-1-am2-2000, Electrical equipment for measure- ment, control and laboratory use - EMC requirements - Part 1: General requirements. American National Standards Projects...

  12. Gas Generation from Actinide Oxide Materials

    SciTech Connect (OSTI)

    George Bailey; Elizabeth Bluhm; John Lyman; Richard Mason; Mark Paffett; Gary Polansky; G. D. Roberson; Martin Sherman; Kirk Veirs; Laura Worl

    2000-12-01T23:59:59.000Z

    This document captures relevant work performed in support of stabilization, packaging, and long term storage of plutonium metals and oxides. It concentrates on the issue of gas generation with specific emphasis on gas pressure and composition. Even more specifically, it summarizes the basis for asserting that materials loaded into a 3013 container according to the requirements of the 3013 Standard (DOE-STD-3013-2000) cannot exceed the container design pressure within the time frames or environmental conditions of either storage or transportation. Presently, materials stabilized and packaged according to the 3013 Standard are to be transported in certified packages (the certification process for the 9975 and the SAFKEG has yet to be completed) that do not rely on the containment capabilities of the 3013 container. Even though no reliance is placed on that container, this document shows that it is highly likely that the containment function will be maintained not only in storage but also during transportation, including hypothetical accident conditions. Further, this document, by summarizing materials-related data on gas generation, can point those involved in preparing Safety Analysis Reports for Packages (SARPs) to additional information needed to assess the ability of the primary containment vessel to contain the contents and any reaction products that might reasonably be produced by the contents.

  13. Rhode Island Stormwater Design and Installation Standards Manual (Rhode Island)

    Broader source: Energy.gov [DOE]

    Rhode Island's stormwater design and installation standards manual has been developed to describe mandatory and suggested stormwater design and performance criteria for applicants to the Department...

  14. DEMONSTRATION OF THE DOE INTERIM ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL RESIDENTIAL BUILDINGS

    SciTech Connect (OSTI)

    Lee, A. D.; Baechler, H. C.; Di Massa, F. V.; Lucas, R. G.; Shankle, D. L.

    1992-01-01T23:59:59.000Z

    In accordance with federal legislation, the U.S. Department of Energy (DOE) has sponsored a study to demonstrate use of its Interim Energy Conservation Standards for New Federal Residential Buildings. The demonstration study was conducted by DOE and the Pacific Northwest Laboratory (PNL). The demonstration is the second step in a three-step process: I) development of interim standards, 2) demonstration of the interim standards, and 3) development of final standards. The standards are mandatory for federal agency housing procurements. Nevertheless, PNL found at the start of the demonstration that agency use of the interim standards had been minimal. The purpose of the standards is to improve the energy efficiency of federal housing and increase the use of nondepletable energy sources. In accordance with the legislation, the standards were to be performance-based rather than prescribing specific energy conservation measures. To fulfill this aspect of the legislation, the standards use a computer software program called COSTSAFR which generates a point system that individualizes the standards to specific projects based on climate, housing type, and fuel costs. The standards generate minimum energy-efficiency requirements by applying the life-cycle cost methodology developed for federal projects. For the demonstration, PNL and DOE chose five federal agency housing projects which had been built in diverse geographic and climate regions. Participating agencies were the Air Force, the Army (which provided two case studies), the Navy, and the Department of Health and Human Services. PNL worked with agency housing procurement officials and designers/architects to hypothetically apply the interim standards to the procurement and design of each housing project. The demonstration started at the point in the project where agencies would establish their energyefficiency requirements for the project and followed the procurement process through the designers' use of the point system to develop a design which would comply with the standards. PNL conducted extensive interviews with the federal agencies and design contractors to determine what impacts the standards would have on the existing agency procurement process as well as on designers. Overall, PNL found that the interim standards met the basic intent of the law. Specific actions were identified, however, that DOE could take to improve the standards and encourage the agencies to implement them. Agency personnel found the minimum efficiency levels established by the standards to be lower than expected, and lower than their existing requirements. Generally, this was because the standards factor in fuel costs, as well as energy savings due to various conservation measures such as insulation, when they determine the minimum efficiency levels required. The demonstration showed that federal agencies often pay low prices for heating fuel and electricity; these lower costs "tipped the scales," allowing designers to meet the efficiency target with designs that were relatively inefficient. It appeared, however, that the low prices paid by agencies directly to suppliers did not capture the agencies' full costs of providing energy, such as the costs of distribution and storage. Agency personnel expressed some concern about the standards' ability to incorporate new energy-efficient technologies and renewable resource technologies like solar heating systems. An alternative compliance procedure was developed to incorporate new technologies; however, demonstration participants said the procedure was not well documented and was difficult and time consuming to use. Despite these concerns, most agency personnel thought that the standards would fit into current procurement procedures with no big changes or cost increases. Many said use of the standards would decrease the time and effort they now spend to establish energy-efficiency requirements and to confirm that proposed designs comply. Personnel praised the software and documentation for being easy to use and providing energ

  15. Performance indicators for first quarter CY 1994

    SciTech Connect (OSTI)

    Not Available

    1994-11-01T23:59:59.000Z

    The Department of Energy (DOE) has established a Department-Wide Performance Indicator (PI) Program for trending and analysis of operational data as directed by DOE Order 5480.26. The PI Program was established to provide a means for monitoring the environment safety, and health (ES&H) performance of the DOE at the Secretary and other management levels. This is the thirteenth in a series of quarterly reports generated for the Department of Energy Idaho Operations Office (DOE-ID) by EG&G Idaho, Inc., to meet the requirements of the PI Program as directed by the DOE Standard (DOE-STD-1048-92). The report format and content adhere to the guidelines established In DOE Order 5480.26, Trending and Analysis of Operations Information Using Performance Indicators, and DOE-STD-1048-92, DOE Peformance Indicators Guidance Document.

  16. MODEL CONSERVATION STANDARD INTRODUCTION

    E-Print Network [OSTI]

    programs, the standard for all new commercial buildings, the standard for utility commercial conservation RESIDENTIAL AND COMMERCIAL BUILDINGS The region should acquire all electric energy conservation measure savings from new residential and new commercial buildings that have a benefit-to-cost ratio greater than

  17. Dynamic Simulation Studies of the Frequency Response of the Three U.S. Interconnections with Increased Wind Generation

    E-Print Network [OSTI]

    Mackin, Peter

    2011-01-01T23:59:59.000Z

    2009. “North America Dynamic Wind Generator Modeling Update,work performed by the WECC Wind Generator Modeling Group andIEEE Dynamic Performance of Wind Power Generation Working

  18. Stochastic Generator of Chemical Structure. 3. Reaction Network Generation

    SciTech Connect (OSTI)

    FAULON,JEAN-LOUP; SAULT,ALLEN G.

    2000-07-15T23:59:59.000Z

    A new method to generate chemical reaction network is proposed. The particularity of the method is that network generation and mechanism reduction are performed simultaneously using sampling techniques. Our method is tested for hydrocarbon thermal cracking. Results and theoretical arguments demonstrate that our method scales in polynomial time while other deterministic network generator scale in exponential time. This finding offers the possibility to investigate complex reacting systems such as those studied in petroleum refining and combustion.

  19. Cognitive Functionality in Next Generation Wireless Networks: Standardization Efforts

    E-Print Network [OSTI]

    Shihada, Basem

    is with Western Telecom Consultants, Inc., 1168 Fletcher Drive, Eire, Colorado 80561, email: jhoffmeyer@ieee.org. H. Stephen Berger is with TEM Consulting, LP, 140 River Road, Georgetown, Texas 78628, email Company, projects like DARPA's XG, EU's E2R and Dutch AAF, and research groups in numerous universities

  20. A Standard Soot Generator for Diesel Particulate Filter Testing |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny: The Future of BadTHEEnergyReliability2015GrossA4,DepartmentDepartment of

  1. DOE Coordination Meeting CODES & STANDARDS

    E-Print Network [OSTI]

    of the International Standards Organization's standards for hydrogen refueling and storage, by 2006; · Complete. Provide technical resources to harmonize the development of international standards among IEC, ISO negotiations with critical Standard Development Organizations and develop draft generic licensing agreement

  2. DOE technical standards list. Department of Energy standards index

    SciTech Connect (OSTI)

    NONE

    1995-08-01T23:59:59.000Z

    This document was prepared for use by personnel involved in the selection and use of DOE technical standards and other Government and non-Government standards. This TSL provides listing of current DOE technical standards, non-Government standards that have been adopted by DOE, other Government documents in which DOE has a recorded interest, and canceled DOE technical standards. Information on new DOE technical standards projects, technical standards released for coordination, recently published DOE technical standards, and activities of non-Government standards bodies that may be of interest to DOE is published monthly in Standards Actions.

  3. Sonication standard laboratory module

    DOE Patents [OSTI]

    Beugelsdijk, Tony (Los Alamos, NM); Hollen, Robert M. (Los Alamos, NM); Erkkila, Tracy H. (Los Alamos, NM); Bronisz, Lawrence E. (Los Alamos, NM); Roybal, Jeffrey E. (Santa Fe, NM); Clark, Michael Leon (Menan, ID)

    1999-01-01T23:59:59.000Z

    A standard laboratory module for automatically producing a solution of cominants from a soil sample. A sonication tip agitates a solution containing the soil sample in a beaker while a stepper motor rotates the sample. An aspirator tube, connected to a vacuum, draws the upper layer of solution from the beaker through a filter and into another beaker. This beaker can thereafter be removed for analysis of the solution. The standard laboratory module encloses an embedded controller providing process control, status feedback information and maintenance procedures for the equipment and operations within the standard laboratory module.

  4. Second generation PFB for advanced power generation

    SciTech Connect (OSTI)

    Robertson, A.; Van Hook, J.

    1995-11-01T23:59:59.000Z

    Research is being conducted under a United States Department of Energy (USDOE) contract to develop a new type of coal-fueled plant for electric power generation. This new type of plant-called an advanced or second-generation pressurized fluidized bed combustion (APFBC) plant-offers the promise of 45-percent efficiency (HHV), with emissions and a cost of electricity that are significantly lower than conventional pulverized-coal-fired plants with scrubbers. This paper summarizes the pilot plant R&D work being conducted to develop this new type of plant. Although pilot plant testing is still underway, preliminary estimates indicate the commercial plant Will perform better than originally envisioned. Efficiencies greater than 46 percent are now being predicted.

  5. Vortex generation in protoplanetary disks with an embedded giant planet

    E-Print Network [OSTI]

    M. de Val-Borro; P. Artymowicz; G. D'Angelo; A. Peplinski

    2007-06-21T23:59:59.000Z

    Vortices in protoplanetary disks can capture solid particles and form planetary cores within shorter timescales than those involved in the standard core-accretion model. We investigate vortex generation in thin unmagnetized protoplanetary disks with an embedded giant planet with planet to star mass ratio $10^{-4}$ and $10^{-3}$. Two-dimensional hydrodynamical simulations of a protoplanetary disk with a planet are performed using two different numerical methods. The results of the non-linear simulations are compared with a time-resolved modal analysis of the azimuthally averaged surface density profiles using linear perturbation theory. Finite-difference methods implemented in polar coordinates generate vortices moving along the gap created by Neptune-mass to Jupiter-mass planets. The modal analysis shows that unstable modes are generated with growth rate of order $0.3 \\Omega_K$ for azimuthal numbers m=4,5,6, where $\\Omega_K$ is the local Keplerian frequency. Shock-capturing Cartesian-grid codes do not generate very much vorticity around a giant planet in a standard protoplanetary disk. Modal calculations confirm that the obtained radial profiles of density are less susceptible to the growth of linear modes on timescales of several hundreds of orbital periods. Navier-Stokes viscosity of the order $\

  6. DOE technical standards list: Department of Energy standards index

    SciTech Connect (OSTI)

    NONE

    1999-05-01T23:59:59.000Z

    This Department of Energy (DOE) technical standards list (TSL) has been prepared by the Office of Nuclear Safety Policy and Standards (EH-31) on the basis of currently available technical information. Periodic updates of this TSL will be issued as additional information is received on standardization documents being issued, adopted, or canceled by DOE. This document was prepared for use by personnel involved in the selection and use of DOE technical standards and other Government and non-Government standards. This TSL provides listings of current DOE technical standards, non-Government standards that have been adopted by DOE, other standards-related documents in which DOE has a recorded interest, and canceled DOE technical standards. Information on new DOE technical standards projects, technical standards released for coordination, recently published DOE technical standards, and activities of non-Government standards bodies that may be of interest to DOE is published monthly in Standards Actions.

  7. Parametrization-independent elliptic surface grid generation

    E-Print Network [OSTI]

    Rasmussen, Britt Bille

    2009-01-01T23:59:59.000Z

    The generation of computational grids on surfaces of three-dimensional configurations is an important component of many areas of computational research, both as a boundary grid for volume grid generation or to perform ...

  8. Renewable Energy Standard

    Broader source: Energy.gov [DOE]

    With the passage of [http://www.secstate.wa.gov/elections/initiatives/text/I937.pdf Initiative 937] in 2006, Washington became the second state after Colorado to pass a renewable energy standard by...

  9. Roundness calibration standard

    DOE Patents [OSTI]

    Burrus, Brice M. (6620 Wachese La., Knoxville, TN 37912)

    1984-01-01T23:59:59.000Z

    A roundness calibration standard is provided with a first arc constituting the major portion of a circle and a second arc lying between the remainder of the circle and the chord extending between the ends of said first arc.

  10. Energy Efficiency Resource Standard

    Broader source: Energy.gov [DOE]

    In 2008, New Mexico enacted H.B. 305, the Efficient Use of Energy Act, which created an Energy Efficiency Resource Standard (EERS) for New Mexico’s electric utilities, and a requirement that all ...

  11. Standards Actions, July 2001

    Broader source: Energy.gov (indexed) [DOE]

    - Standard method for testing the long-term alpha irradiation stability of so- lidified high-level radioactive waste forms - Septem- ber 8, 2001. * ISODIS 14830-1, Condition...

  12. August 2001 Standards Actions

    Broader source: Energy.gov (indexed) [DOE]

    - May 10, 2001. ANSIASTM D6239-01, Test Method for Uranium in Drinking Water by High-Resolution Alpha-Liquid- Scintillation Spectrometry (new standard) - May 22, 2001....

  13. Building Energy Standards

    Broader source: Energy.gov [DOE]

    The 2015 Vermont Commercial Building Energy Standards (CBES) took effect on March 1, 2015. The code is based on the 2015 IECC, with amendments to incorporate ASHRAE 90.1-2013. The new guidelines ...

  14. Technical Standards Program

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2011-02-23T23:59:59.000Z

    The order establishes the DOE Technical Standards Program. Cancels DOE O 252.1 and DOE G 252.1-1. Admin Chg 1, dated 3-12-13 cancels DOE O 252.1A.

  15. Drinking Water Standards

    E-Print Network [OSTI]

    Dozier, Monty; McFarland, Mark L.

    2006-04-26T23:59:59.000Z

    This publication explains the federal safety standards for drinking water provided by public water supply systems. It discusses the legal requirements for public water supplies, the maximum level allowed for contaminants in the water...

  16. Standards Actions, May 2001

    Broader source: Energy.gov (indexed) [DOE]

    Standards are proposed for reaffirmation: * DOE-HDBK-1081-94, Primer on Spontaneous Heating and Pyrophoricity, Decem- ber 1994. * DOE-STD-1027-92, including Change Notice 1,...

  17. Renewables Portfolio Standard

    Broader source: Energy.gov [DOE]

    In January 2005, the District of Columbia Council enacted a renewable portfolio standard (RPS) that applies to all retail electricity sales in the District. In October 2008 the RPS was amended by...

  18. FREIGHT CONTAINER LIFTING STANDARD

    SciTech Connect (OSTI)

    POWERS DJ; SCOTT MA; MACKEY TC

    2010-01-13T23:59:59.000Z

    This standard details the correct methods of lifting and handling Series 1 freight containers following ISO-3874 and ISO-1496. The changes within RPP-40736 will allow better reading comprehension, as well as correcting editorial errors.

  19. February 2002 Standards Actions

    Broader source: Energy.gov (indexed) [DOE]

    Protection of Electronic Com- puterData Processing Equipment (revision of ANSINFPA 75-1999) - February 26, 2002. NFPA 80, Standard for Fire Doors and Fire Windows (revision of...

  20. Standardization of Firearms

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2000-03-02T23:59:59.000Z

    Establishes Department of Energy (DOE) requirements for the standardization of firearms and limitations of firearms inventories maintained in support of safeguards and security activities. Does not cancel other directives.

  1. Reliability Standards Owner

    Broader source: Energy.gov [DOE]

    This position is located in the Internal Operations and Asset Management group of Planning and Asset Management (TP). A successful candidate in this position will serve as the Reliability Standards...

  2. Low Carbon Fuel Standards

    E-Print Network [OSTI]

    Sperling, Dan; Yeh, Sonia

    2009-01-01T23:59:59.000Z

    S O N I A YE H Low Carbon Fuel Standards The most direct andalternative transportation fuels is to spur innovation withstandard for upstream fuel producers. hen it comes to energy

  3. Energy Efficiency Standard

    Broader source: Energy.gov [DOE]

    In 2008, Iowa enacted S.B. 2386, which requires the Iowa Utilities Board (IUB) to create energy savings standards (electricity and natural gas) for all rate-regulated utilities. The IUB ordered...

  4. EPCglobal : a universal standard

    E-Print Network [OSTI]

    Aguirre, Juan Ignacio

    2007-01-01T23:59:59.000Z

    This thesis evaluates the likelihood of EPCglobal becoming the universal RFID standard by presenting a framework of ten factors used to analyze and determine if EPCglobal is moving in the right direction. The ten factors ...

  5. Standards Actions, April 2000

    Broader source: Energy.gov (indexed) [DOE]

    Technical Standard on this matter no longer exists. Occupational Safety and Health Handbook, Project Number HFAC-0011; Terry Krietz, EH-51; 301-903-6456, Fax 301-903-2239,...

  6. Power Performance Test Report for the SWIFT Wind Turbine

    SciTech Connect (OSTI)

    Mendoza, I.; Hur, J.

    2012-12-01T23:59:59.000Z

    This report summarizes the results of a power performance test that NREL conducted on the SWIFT wind turbine. This test was conducted in accordance with the International Electrotechnical Commission's (IEC) standard, Wind Turbine Generator Systems Part 12: Power Performance Measurements of Electricity Producing Wind Turbines, IEC 61400-12-1 Ed.1.0, 2005-12. However, because the SWIFT is a small turbine as defined by IEC, NREL also followed Annex H that applies to small wind turbines. In these summary results, wind speed is normalized to sea-level air density.

  7. SAE Standards Support

    SciTech Connect (OSTI)

    Gowri, Krishnan

    2012-11-01T23:59:59.000Z

    This report summarizes PNNL activities in FY 2012 in support of the following two vehicle communication standards activities: • Technical support to SAE, ANSI and NIST technical working groups. PNNL actively contributed to the use case development, harmonization, and evaluation of the SAE standards activities for vehicle to grid communication • Tested and validated a set of potential technologies for meeting SAE communication requirements and provided recommendations for technology choices.

  8. Surface Water Quality Standards

    E-Print Network [OSTI]

    Wythe, Kathy

    2007-01-01T23:59:59.000Z

    recreational uses. ?The Commission will seek substantial additional public comment on any proposed changes to the standards before adopting them into the state admin- istrative code,? Davenport said. ?Because of the com- plexity and regulatory importance... Conservation Board?s state watershed coordinator, said the standards for contact recreation, with only a few exceptions, are uniformly applied regardless of water body type or the actual level of recreation use. ?Because a minimum of 10 water samples over a...

  9. Chaotic generation of pseudo-random numbers

    E-Print Network [OSTI]

    Dornbusch, Andrew Wesley

    1999-01-01T23:59:59.000Z

    Generation of repeatable pseudo-random sequences with chaotic analog electronics is not feasible using standard circuit topologies. Component variation caused by imperfect fabrication causes the same divergence of output sequences as does varying...

  10. Performance Metrics Research Project - Final Report

    SciTech Connect (OSTI)

    Deru, M.; Torcellini, P.

    2005-10-01T23:59:59.000Z

    NREL began work for DOE on this project to standardize the measurement and characterization of building energy performance. NREL's primary research objectives were to determine which performance metrics have greatest value for determining energy performance and to develop standard definitions and methods of measuring and reporting that performance.

  11. Renewable Power Options for Electricity Generation on Kaua'i...

    Office of Environmental Management (EM)

    Renewable Power Options for Electricity Generation on Kaua'i: Economics and Performance Modeling Renewable Power Options for Electricity Generation on Kaua'i: Economics and...

  12. Feasibility Study of Economics and Performance of Solar Photovoltaics at the Standard Chlorine of Delaware Superfund Site in Delaware City, Delaware. A Study Prepared in Partnership with the Environmental Protection Agency for the RE-Powering America's Land Initiative: Siting Renewable Energy on Potentially Contaminated Land and Mine Sites

    SciTech Connect (OSTI)

    Salasovich, J.; Geiger, J.; Mosey, G.; Healey, V.

    2013-06-01T23:59:59.000Z

    The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the Standard Chlorine of Delaware site in Delaware City, Delaware, for a feasibility study of renewable energy production. The National Renewable Energy Laboratory (NREL) provided technical assistance for this project. The purpose of this report is to assess the site for a possible photovoltaic (PV) system installation and estimate the cost, performance, and site impacts of different PV options. In addition, the report recommends financing options that could assist in the implementation of a PV system at the site.

  13. Seminar on Software Engineering Software Standards

    E-Print Network [OSTI]

    Feitelson, Dror

    is that there are so many of them" #12;Types of Standards Coding standards APIs and protocols Process standards Quality standards #12;Types of Standards Coding standards APIs and protocols Process standards Quality standards of Standards Coding standards APIs and protocols Process standards Quality standards STL and Java libraries

  14. Technical Standards, Style Guide- August 1, 2000

    Broader source: Energy.gov [DOE]

    Style Guide for the Preparation of DOE Technical Standards (Standards, Handbooks, and Technical Standards Lists)

  15. Global Potential of Energy Efficiency Standards and Labeling Programs

    SciTech Connect (OSTI)

    McNeil, Michael A; McNeil, Michael A.; Letschert, Virginie; de la Rue du Can, Stephane

    2008-06-15T23:59:59.000Z

    This report estimates the global potential reductions in greenhouse gas emissions by 2030 for energy efficiency improvements associated with equipment (appliances, lighting, and HVAC) in buildings by means of energy efficiency standards and labels (EES&L). A consensus has emerged among the world's scientists and many corporate and political leaders regarding the need to address the threat of climate change through emissions mitigation and adaptation. A further consensus has emerged that a central component of these strategies must be focused around energy, which is the primary generator of greenhouse gas emissions. Two important questions result from this consensus: 'what kinds of policies encourage the appropriate transformation to energy efficiency' and 'how much impact can these policies have'? This report aims to contribute to the dialogue surrounding these issues by considering the potential impacts of a single policy type, applied on a global scale. The policy addressed in this report is Energy Efficient Standards and Labeling (EES&L) for energy-consuming equipment, which has now been implemented in over 60 countries. Mandatory energy performance standards are important because they contribute positively to a nation's economy and provide relative certainty about the outcome (both timing and magnitudes). Labels also contribute positively to a nation's economy and importantly increase the awareness of the energy-consuming public. Other policies not analyzed here (utility incentives, tax credits) are complimentary to standards and labels and also contribute in significant ways to reducing greenhouse gas emissions. We believe the analysis reported here to be the first systematic attempt to evaluate the potential of savings from EES&L for all countries and for such a large set of products. The goal of the analysis is to provide an assessment that is sufficiently well-quantified and accurate to allow comparison and integration with other strategies under consideration.

  16. Tracking Grantee Portal Standards and Recommendations Standards and Recommendations Table

    E-Print Network [OSTI]

    Tracking Grantee Portal Standards and Recommendations April 2009 Standards and Recommendations Table Tracking Network Standards Provide both public and secure grantee portals. Provide a link on a grantee's portal. Organize contents of pages to facilitate the identification of detailed information

  17. Renewable Portfolio Standard

    E-Print Network [OSTI]

    Hydroelectric Project as its original baseline eligible renewable energy resource project, and MID also hydroelectric unit, the Stone Drop Electric Generation Station (the Stone Drop Station). The Stone Drop

  18. Energy Efficiency Resource Standard

    Broader source: Energy.gov [DOE]

    In 2007, the Minnesota legislature passed the Next Generation Energy Act (NGEA), which requires both electric and natural gas investor-owned utilities to reduce energy sales, and spend a minimum ...

  19. Energy Efficiency Resource Standard

    Broader source: Energy.gov [DOE]

    In 2007, the Minnesota legislature passed the Next Generation Energy Act (NGEA), which requires both electric and natural gas investor-owned utilities to reduce energy sales by 1.5% of average...

  20. Department of Energy Standards Index

    SciTech Connect (OSTI)

    NONE

    1995-08-01T23:59:59.000Z

    This TSL, intended for use in selecting and using DOE technical standards and other Government and non-Government standards, provides listing of current and inactive DOE technical standards, non-Government standards adopted by DOE, other Government documents in which DOE has a recorded interest, and cancelled DOE technical standards.

  1. DOE technical standards list: Department of Energy standards index

    SciTech Connect (OSTI)

    NONE

    1997-06-01T23:59:59.000Z

    This technical standards list (TSL) was prepared for use by personnel involved in the selection and use of US DOE technical standards and other government and non-government standards. This TSL provides listings of current DOE technical standards, non-government standards that have been adopted by DOE, other government documents in which DOE has a recorded interest, and cancelled DOE technical standards. Standards are indexed by type in the appendices to this document. Definitions of and general guidance for the use of standards are also provided.

  2. High-quality polarization entanglement state preparation and manipulation in standard telecommunication channels

    E-Print Network [OSTI]

    F. Kaiser; A. Issautier; L. A. Ngah; O. Danila; H. Herrmann; W. Sohler; A. Martin; S. Tanzilli

    2012-07-16T23:59:59.000Z

    We report a novel and simple approach for generating near-perfect quality polarization entanglement in a fully guided-wave fashion. Both deterministic pair separation into two adjacent telecommunication channels and the paired photons' temporal walk-off compensation are achieved using standard fiber components. Two-photon interference experiments are performed, both for quantitatively demonstrating the relevance of our approach, and for manipulating the produced state between bosonic and fermionic symmetries. The compactness, versatility, and reliability of this configuration makes it a potential candidate for quantum communication applications.

  3. Beyond standard model calculations with Sherpa

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Höche, Stefan; Kuttimalai, Silvan; Schumann, Steffen; Siegert, Frank

    2015-03-01T23:59:59.000Z

    We present a fully automated framework as part of the Sherpa event generator for the computation of tree-level cross sections in beyond Standard Model scenarios, making use of model information given in the Universal FeynRules Output format. Elementary vertices are implemented into C++ code automatically and provided to the matrix-element generator Comix at runtime. Widths and branching ratios for unstable particles are computed from the same building blocks. The corresponding decays are simulated with spin correlations. Parton showers, QED radiation and hadronization are added by Sherpa, providing a full simulation of arbitrary BSM processes at the hadron level.

  4. Beyond Standard Model calculations with Sherpa

    E-Print Network [OSTI]

    Stefan Höche; Silvan Kuttimalai; Steffen Schumann; Frank Siegert

    2014-12-19T23:59:59.000Z

    We present a fully automated framework as part of the Sherpa event generator for the computation of tree-level cross sections in beyond Standard Model scenarios, making use of model information given in the Universal FeynRules Output format. Elementary vertices are implemented into C++ code automatically and provided to the matrix-element generator Comix at runtime. Widths and branching ratios for unstable particles are computed from the same building blocks. The corresponding decays are simulated with spin correlations. Parton showers, QED radiation and hadronization are added by Sherpa, providing a full simulation of arbitrary BSM processes at the hadron level.

  5. 3-D seismic surveys generate 5-D data volume. In order to estimate the horizons for interpretation and further processing, the traveltime picking needs to be performed on n-D subsets of this 5-D data volume (n5). Horizon

    E-Print Network [OSTI]

    Nicoli, Monica

    Abstract 3-D seismic surveys generate 5-D data volume. In order to estimate the horizons for interpretation and further processing, the traveltime picking needs to be performed on n-D subsets of this 5-D to support the interpreters in the estimation of the events by preserving their depth continuity. The HP

  6. High efficiency radioisotope thermophotovoltaic prototype generator

    SciTech Connect (OSTI)

    Avery, J.E.; Samaras, J.E.; Fraas, L.M.; Ewell, R. [JX Crystals, Inc., Issaquah, WA (United States)

    1995-10-01T23:59:59.000Z

    A radioisotope thermophotovoltaic generator space power system (RTPV) is lightweight, low-cost alternative to the present radioisotope thermoelectric generator system (RTG). The fabrication of such an RTPV generator has recently become feasible as the result of the invention of the GaSb infrared sensitive photovoltaic cell. Herein, the authors present the results of a parametric study of emitters and optical filters in conjuction with existing data on gallium antimonide cells. They compare a polished tungsten emitter with an Erbia selective emitter for use in combination with a simple dielectric filter and a gallium antimonide cell array. They find that the polished tungsten emitter is by itself a very selective emitter with low emissivity beyond 4 microns. Given a gallium antimonide cell and a tungsten emitter, a simple dielectric filter can be designed to transmit radiant energy below 1.7 microns and to reflect radiant energy between 1.7 and 4 microns back to the emitter. Because of the low long wavelength emissivity associated with the polished tungsten emitter, this simple dielectric filter then yields very respectable system performance. Also as a result of the longer wavelength fall-off in the tungsten emissivity curve, the radiation energy peak for a polished tungsten emitter operating at 1300 K shifts to shorter wavelengths relative to the blackbody spectrum so that the radiated energy peak falls right at the gallium antimonide cell bandedge. The result is that the response of the gallium antimonide cell is well matched to a polished tungsten emitter. The authors propose, therefore, to fabricate an operating prototype of a near term radioisotope thermophotovoltaic generator design consisting of a polished tungsten emitter, standard gallium antimonide cells, and a near-term dielectric filter.

  7. Maintaining Standards: Differences between the Standard Deviation and Standard Error, and

    E-Print Network [OSTI]

    California at Santa Cruz, University of

    Maintaining Standards: Differences between the Standard Deviation and Standard Error, and When to Use Each David L Streiner, PhD1 Many people confuse the standard deviation (SD) and the standard error of the mean (SE) and are unsure which, if either, to use in presenting data in graphical or tabular form

  8. Standard Nine: Financial Resources

    E-Print Network [OSTI]

    Snider, Barry B.

    105 Standard Nine: Financial Resources Overview The 1996 NEASC team report was critical of Brandeis's financial management, and focused on the need to increase financial resources, improve faculty and staff displays the University resource profile for FY1995 compared to the FY2005 profile. During this decade

  9. Derived Concentration Technical Standard

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2011-05-05T23:59:59.000Z

    This standard supports the implementation of Department of Energy (DOE) Order 458.1, Radiation Protection of the Public and the Environment. It also establishes the numerical values of DCSs in a manner reflecting the current state of knowledge and practice in radiation protection

  10. FACILITIES INSTRUCTIONS, STANDARDS, & TECHNIQUES

    E-Print Network [OSTI]

    Laughlin, Robert B.

    to the repair of hydraulic turbine runners and large pump impellers. Reclamation operates and maintains a wideFACILITIES INSTRUCTIONS, STANDARDS, & TECHNIQUES VOLUME 2-5 TURBINE REPAIR Internet Version variety of reaction and impulse turbines as well as axial flow, mixed flow, radial flow pumps and pump

  11. A Distributed Generation Control Architecture for Islanded AC Microgrids

    E-Print Network [OSTI]

    Dominguez-Garcia, Alejandro

    1 A Distributed Generation Control Architecture for Islanded AC Microgrids Stanton T. Cady, Student architecture for generation control in islanded microgrids, and illustrate the performance Member, IEEE Abstract In this paper, we propose a distributed architecture for generation control

  12. DOE standard: Radiological control

    SciTech Connect (OSTI)

    Not Available

    1999-07-01T23:59:59.000Z

    The Department of Energy (DOE) has developed this Standard to assist line managers in meeting their responsibilities for implementing occupational radiological control programs. DOE has established regulatory requirements for occupational radiation protection in Title 10 of the Code of Federal Regulations, Part 835 (10 CFR 835), ``Occupational Radiation Protection``. Failure to comply with these requirements may lead to appropriate enforcement actions as authorized under the Price Anderson Act Amendments (PAAA). While this Standard does not establish requirements, it does restate, paraphrase, or cite many (but not all) of the requirements of 10 CFR 835 and related documents (e.g., occupational safety and health, hazardous materials transportation, and environmental protection standards). Because of the wide range of activities undertaken by DOE and the varying requirements affecting these activities, DOE does not believe that it would be practical or useful to identify and reproduce the entire range of health and safety requirements in this Standard and therefore has not done so. In all cases, DOE cautions the user to review any underlying regulatory and contractual requirements and the primary guidance documents in their original context to ensure that the site program is adequate to ensure continuing compliance with the applicable requirements. To assist its operating entities in achieving and maintaining compliance with the requirements of 10 CFR 835, DOE has established its primary regulatory guidance in the DOE G 441.1 series of Guides. This Standard supplements the DOE G 441.1 series of Guides and serves as a secondary source of guidance for achieving compliance with 10 CFR 835.

  13. Energy Efficiency Standards for Appliances

    Broader source: Energy.gov [DOE]

    '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of...

  14. Appliance and Equipment Efficiency Standards

    Broader source: Energy.gov [DOE]

    '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of...

  15. Active Technical Standards Managers List

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    TECHNICAL STANDARDS PROGRAM ASSIGNMENT TELEPHONEFAXEMAIL NAME DOE FACILITYADDRESS LOC CODE AU-30 Jeff D. Feit DOE Technical Standards Program, Manager U.S. Department of Energy...

  16. Water Quality Standards Implementation (Oklahoma)

    Broader source: Energy.gov [DOE]

    The Oklahoma Department of Environmental Quality regulates Oklahoma's Water Quality Standards. The law states the requirements and standards for point source discharges. It also establishes...

  17. Labor Standards for Construction

    Energy Savers [EERE]

    emphasis on high performance sustainable buildings including planning and targets for zero net energy buildings. The new Order requires that 95 percent of all new contract...

  18. STANDARD USER AGREEMENT

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    addressed in Article IX. USER may be permitted by the Contractor to furnish equipment, tooling, test apparatus, or materials necessary to assist in the performance of its...

  19. Codes and Standards

    Broader source: Energy.gov [DOE]

    A primary objective of DOE's technology validation efforts is developing testing, monitoring, and analysis protocols for validating the performance, reliability, and safety of solar photovoltaic ...

  20. Generation Planning (pbl/generation)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField8,Dist.Newof EnergyFundingGene ControlsCounselGeneral User Generation

  1. UCIT Data Network Standards Campus Wireless Network Standard

    E-Print Network [OSTI]

    Habib, Ayman

    UCIT Data Network Standards Campus Wireless Network Standard Classification IT Infrastructure Table.1. Standardization of the U of C's 802.11 wireless networks and frequency bands is required to insure availability of the wireless network to the campus community. Standards of use will improve the wireless service and help

  2. Performance indicators for 4th quarter CY 1993

    SciTech Connect (OSTI)

    Not Available

    1994-11-01T23:59:59.000Z

    The Department of Energy (DOE) has established a Department-wide Performance Indicator (PI) Program for trending and analysis of operational data as directed by DOE Order 5480.26. The PI Program was established to provide a means for monitoring the environment, safety, and health (ES&H) performance of the DOE at the Secretary and other management levels. This is the twelfth in a series of quarterly reports generated for the Department of Energy Idaho Operations Office (DOE-ID) by EG&G Idaho, Inc., to meet the requirements of the PI Program as directed by the DOE Standard (DOE-STD-1048-92). The report format and content adhere to the guidelines established in DOE Order 5480.26, Trending and Analysis of Operations Information Using Performance Indicators, and DOE-STD-1048-92, DOE Performance Indicators Guidance Document.

  3. Performance indicators for 2nd quarter CY 1994

    SciTech Connect (OSTI)

    Not Available

    1994-11-01T23:59:59.000Z

    The Department of Energy (DOE) has established a Department-wide Performance Indicator (PI) Program for trending and analysis of operational data as directed by DOE Order 5480.26. The PI Program was established to provide a means for monitoring the environment, safety, and health (ES&H) performance of the DOE at the Secretary and other management levels. This is the fourteenth in a series of quarterly reports generated for the Department of Energy Idaho Operations Office (DOE-ID) by EG&G Idaho, Inc., to meet the requirements of the PI Program as directed by the DOE Standard (DOE-STD-1048-92). The report format and content adhere to the guidelines established in DOE Order 5480.26, Trending and Analysis of Operations Information Using Performance Indicators, and DOE-STD-1048-92, DOE Performance Indicators Guidance Document.

  4. Standardized radiological dose evaluations

    SciTech Connect (OSTI)

    Peterson, V.L.; Stahlnecker, E.

    1996-05-01T23:59:59.000Z

    Following the end of the Cold War, the mission of Rocky Flats Environmental Technology Site changed from production of nuclear weapons to cleanup. Authorization baseis documents for the facilities, primarily the Final Safety Analysis Reports, are being replaced with new ones in which accident scenarios are sorted into coarse bins of consequence and frequency, similar to the approach of DOE-STD-3011-94. Because this binning does not require high precision, a standardized approach for radiological dose evaluations is taken for all the facilities at the site. This is done through a standard calculation ``template`` for use by all safety analysts preparing the new documents. This report describes this template and its use.

  5. Standard costs for labor

    E-Print Network [OSTI]

    Khan, Mohammed Nurul Absar

    1960-01-01T23:59:59.000Z

    STANDARD COSTS FOR LABOR A Thesis By MD. NURUL ABSAR KHAN Submitted to the Graduate School of the Agricultural and Mechanical College of Texms in partial fulfillment of the requirements for the degree of MASTER OF BUSINESS ADMINISTRATION... January 1960 Ma/or Sub)acts Accounting STANOAHD COSTS FOR LABOR ND, NURUL ABSAR KHAN Approved as t style and content bys Chairman of Committee Head of Hepartment January 1960 The author acknowledges his indebtedness to Mr. T. M. Leland, Mr. T. D...

  6. Standard interface file handbook

    SciTech Connect (OSTI)

    Shapiro, A.; Huria, H.C. (Cincinnati Univ., OH (United States))

    1992-10-01T23:59:59.000Z

    This handbook documents many of the standard interface file formats that have been adopted by the US Department of Energy to facilitate communications between and portability of, various large reactor physics and radiation transport software packages. The emphasis is on those files needed for use of the VENTURE/PC diffusion-depletion code system. File structures, contents and some practical advice on use of the various files are provided.

  7. Does Geometric Coupling Generates Resonances?

    E-Print Network [OSTI]

    I. C. Jardim; G. Alencar; R. R. Landim; R. N. Costa Filho

    2015-05-08T23:59:59.000Z

    Geometrical coupling in a co-dimensional one Randall-Sundrum scenario (RS) is used to study resonances of $p-$form fields. The resonances are calculated using the transfer matrix method. The model studied consider the standard RS with delta-like branes, and branes generated by kinks and domain-wall as well. The parameters are changed to control the thickness of the smooth brane. With this a very interesting pattern is found for the resonances. The geometrical coupling does not generate resonances for the reduced $p-$form in all cases considered.

  8. A new standard for core training in radiation safety

    SciTech Connect (OSTI)

    Trinoskey, P.A.

    1997-02-01T23:59:59.000Z

    A new American National Standard for radiation worker training was recently developed. The standard emphasizes performance-based training and establishing a training program rather than simply prescribing objectives. The standard also addresses basic criteria, including instructor qualifications. The standard is based on input from a wide array of regulatory agencies, universities, national laboratories, and nuclear power entities. This paper presents an overview of the new standard and the philosophy behind it. The target audience includes radiation workers, management and supervisory personnel, contractors, students, emergency personnel, and visitors.

  9. TOWARDS INTERNATIONAL STANDARDS FOR LANGUAGE

    E-Print Network [OSTI]

    Boyer, Edmond

    ) developed by the International Standards Organization TC32 SC4, which is to serve as a basis for harmonizingChapter # TOWARDS INTERNATIONAL STANDARDS FOR LANGUAGE RESOURCES Nancy Ide and Laurent Romary-284" #12;2 Chapter # Language Engineering Standards (EAGLES) and the International Standard for Language

  10. Fourth Generation Parity

    SciTech Connect (OSTI)

    Lee, Hye-Sung [William and Mary College, BNL, JLAB; Soni, Amarjit [William and Mary College

    2013-01-01T23:59:59.000Z

    We present a very simple 4th-generation (4G) model with an Abelian gauge interaction under which only the 4G fermions have nonzero charge. The U(1) gauge symmetry can have a Z_2 residual discrete symmetry (4G-parity), which can stabilize the lightest 4G particle (L4P). When the 4G neutrino is the L4P, it would be a neutral and stable particle and the other 4G fermions would decay into the L4P leaving the trace of missing energy plus the standard model fermions. Because of the new symmetry, the 4G particle creation and decay modes are different from those of the sequential 4G model, and the 4G particles can be appreciably lighter than typical experimental bounds.

  11. Thick Buildings [Standards

    E-Print Network [OSTI]

    Coffin, Christie Johnson

    1995-01-01T23:59:59.000Z

    on Occupant Behavior in Buildings, New Directions forSacramento, is a thin building that surrounds an atrium. (Performance of a Green Building," Urban UndQune 1992): 23-

  12. Understanding Building Energy Codes and Standards

    SciTech Connect (OSTI)

    Bartlett, Rosemarie; Halverson, Mark A.; Shankle, Diana L.

    2003-03-01T23:59:59.000Z

    Energy codes and standards play a vital role by setting minimum requirements for energy-efficient design and construction. They outline uniform requirements for new buildings as well as additions and renovations. The Difference Between Energy Codes, Energy Standards and the Model Energy Code Energy codes--specify how buildings must be constructed or perform, and are written in mandatory, enforceable language. States or local governments adopt and enforce energy codes for their jurisdictions. Energy standards--describe how buildings should be constructed to save energy cost-effectively. They are published by national organizations such as the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). They are not mandatory, but serve as national recommendations, with some variation for regional climate. States and local governments frequently use energy standards as the technical basis for developing their energy codes. Some energy standards are written in mandatory, enforceable language, making it easy for jurisdictions to incorporate the provisions of the energy standards directly into their laws or regulations.

  13. Theoretical standards in x-ray spectroscopies

    SciTech Connect (OSTI)

    Not Available

    1992-01-01T23:59:59.000Z

    We propose to extend our state-of-the-art, ab initio XAFS (X-ray absorption fine structure) codes, FEFF. Our current work has been highly successful in achieving accurate, user-friendly XAFS standards, exceeding the performance of both tabulated standards and other codes by a considerable margin. We now propose to add the capability to treat more complex materials. This includes multiple-scattering, polarization dependence, an approximate treatment of XANES (x-ray absorption near edge structure), and other improvements. We also plan to adapt FEFF to other spectroscopies, e.g. photoelectron diffraction (PD) and diffraction anomalous fine structure (DAFS).

  14. Beyond the Standard Model

    SciTech Connect (OSTI)

    Lykken, Joseph D.; /Fermilab

    2010-05-01T23:59:59.000Z

    'BSM physics' is a phrase used in several ways. It can refer to physical phenomena established experimentally but not accommodated by the Standard Model, in particular dark matter and neutrino oscillations (technically also anything that has to do with gravity, since gravity is not part of the Standard Model). 'Beyond the Standard Model' can also refer to possible deeper explanations of phenomena that are accommodated by the Standard Model but only with ad hoc parameterizations, such as Yukawa couplings and the strong CP angle. More generally, BSM can be taken to refer to any possible extension of the Standard Model, whether or not the extension solves any particular set of puzzles left unresolved in the SM. In this general sense one sees reference to the BSM 'theory space' of all possible SM extensions, this being a parameter space of coupling constants for new interactions, new charges or other quantum numbers, and parameters describing possible new degrees of freedom or new symmetries. Despite decades of model-building it seems unlikely that we have mapped out most of, or even the most interesting parts of, this theory space. Indeed we do not even know what is the dimensionality of this parameter space, or what fraction of it is already ruled out by experiment. Since Nature is only implementing at most one point in this BSM theory space (at least in our neighborhood of space and time), it might seem an impossible task to map back from a finite number of experimental discoveries and measurements to a unique BSM explanation. Fortunately for theorists the inevitable limitations of experiments themselves, in terms of resolutions, rates, and energy scales, means that in practice there are only a finite number of BSM model 'equivalence classes' competing at any given time to explain any given set of results. BSM phenomenology is a two-way street: not only do experimental results test or constrain BSM models, they also suggest - to those who get close enough to listen - new directions for BSM model building. Contrary to popular shorthand jargon, supersymmetry (SUSY) is not a BSM model: it is a symmetry principle characterizing a BSM framework with an infinite number of models. Indeed we do not even know the full dimensionality of the SUSY parameter space, since this presumably includes as-yet-unexplored SUSY-breaking mechanisms and combinations of SUSY with other BSM principles. The SUSY framework plays an important role in BSM physics partly because it includes examples of models that are 'complete' in the same sense as the Standard Model, i.e. in principle the model predicts consequences for any observable, from cosmology to b physics to precision electroweak data to LHC collisions. Complete models, in addition to being more explanatory and making connections between diverse phenomena, are also much more experimentally constrained than strawman scenarios that focus more narrowly. One sometimes hears: 'Anything that is discovered at the LHC will be called supersymmetry.' There is truth behind this joke in the sense that the SUSY framework incorporates a vast number of possible signatures accessible to TeV colliders. This is not to say that the SUSY framework is not testable, but we are warned that one should pay attention to other promising frameworks, and should be prepared to make experimental distinctions between them. Since there is no formal classification of BSM frameworks I have invented my own. At the highest level there are six parent frameworks: (1) Terascale supersymmetry; (2) PNGB Higgs; (3) New strong dynamics; (4) Warped extra dimensions; (5) Flat extra dimensions; and (6) Hidden valleys. Here is the briefest possible survey of each framework, with the basic idea, the generic new phenomena, and the energy regime over which the framework purports to make comprehensive predictions.

  15. Performance Based Trending of Waste Disposition

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    standard of performance, and recommends a simple system used to provide a monthly "feedback" mechanism for data quality, which can affect multiple facets of operations. What can...

  16. High Performance Green Schools Planning Grants

    Broader source: Energy.gov [DOE]

    The Governor's Green Government Council of Pennsylvania provides an incentive for new schools to be built according to green building standards. High Performance Green Schools Planning Grants are...

  17. Sandia National Laboratories: information exchange on performance...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    exchange on performance indicators Sandia Contributes to International Electrotechnical Commission IEC 61400-26 Availability Standard On June 12, 2014, in Analysis, Distribution...

  18. Standards | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently AskedEnergyIssues DOE's NuclearSpurring Solar Installations inforStandards

  19. Mechanical Systems Qualification Standard

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport(FactDepartment3311, 3312), October 20122Technologies61-2008 June 2008 DOE STANDARD

  20. HPXML: A Standardized Home Performance Data Sharing System -...

    Energy Savers [EERE]

    & Publications Better Buildings Network View | April 2015 Building Energy Data Exchange Specification Scoping Report Analysis: Targeting Zero Net Energy - 2014 BTO Peer Review...

  1. The Value of the National Performance Standards to

    E-Print Network [OSTI]

    SLE Consulting FBI Investigation Infectious disease investigation ­ Possible scenario ­ Privatized e. PoolsPools ­ Privatized Rabies Consulting SLE Consulting FBI Investigation Infectious disease

  2. Performance of standard rate trickling filters at various depths

    E-Print Network [OSTI]

    Peralta-Rojas, Andres

    1955-01-01T23:59:59.000Z

    o ~ ~ ~ ~ o ~ e ~ ~ ~ ~ ~ ~ ~ e ~ ~ e e o 1 R8++&o ~ ~ ~ ~ ~ ~ e ~ o e ~ ~ ~ e o ~ ~ e e ~ ~ e e e e e e 8 Ills IAXQOC Xolo e o o e e ~ ~ e e e e ~ e o e e e ~ ~ o ~ e 5 HiStm'I. Cal and, Lite~eule GQ&%PJee o ~ ~ ooo ~ e e ~ ~ ~ ee ~ ?& EXPCPi...~o& ~oOgmwg Vol, Wxmo, Si ( ll) Sor x'ale i 0 i Hi snQ ?41 lex'y Pi Si Ai i FiwLge ~iaahis Rocik Piltox's~tt8$ova3. of organ '. exxaFlG of I 01Ui4e Ox'genie Ratter" ~ Seea~xL~4 MC=xctrial '~ asteax Vol, 25, xxo, "Ii 1955? (18) . e ~ause'axe P...

  3. HPXML: A Standardized Home Performance Data Sharing System - Building

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO2: FinalOffers3.pdf0-45.pdf0 BudgetGoals andSenatethe__ PERFORMANCEUSA H2USAHIADeborah

  4. EGov PMA Scorecard Cost, Schedule & Performance Standard.tif

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed off Energy.gov. Are you0andEnergyGlobalEnergy 2014:5 Budget in Brief EERE's FiscalEERE:EGS

  5. U.S. Installation, Operation, and Performance Standards for Microturbine

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn'tOriginEducationVideoStrategic|IndustrialCenterMarchC.DepartmentTexas to CallDepartmentHDV

  6. Standard-E hydrogen monitoring system field acceptance testprocedure

    SciTech Connect (OSTI)

    Schneider, T.C.

    1997-02-01T23:59:59.000Z

    The purpose of this document is to demonstrate that the Standard-E Hydrogen Monitoring Systems (SHMS-E) installed on the Waste Tank Farms in the Hanford 200 Areas are constructed as intended by the design.

  7. New Generation of Digital Microfluidic Devices

    E-Print Network [OSTI]

    Abedian, Behrouz

    This paper reports on the design, fabrication, and performance of micro-sized fluidic devices that use electrowetting to control and transport liquids. Using standard microfabrication techniques, new pumping systems are ...

  8. RVS Bielefeld White Paper 1 Standards for Standards

    E-Print Network [OSTI]

    Ladkin, Peter B.

    in their work and business. Comment on Principle 1: Currently, IEC 61508 in its IEC version is prohibitively of the European and ISO/IEC standards are covered by this; however, if one wants the English originals, this does and includes all IEC standards. However, a certain amount of time and effort is required to use a standard

  9. STANDARD OPERATING PROCEDURES Sampler Maintenance by Site Operators

    E-Print Network [OSTI]

    Fischer, Emily V.

    IMPROVE STANDARD OPERATING PROCEDURES SOP 201 Sampler Maintenance by Site Operators Date Last.0 PURPOSE AND APPLICABILITY This standard operating procedure (SOP) describes the procedures and schedules. The procedural steps for weekly maintenance and repairs performed by the site operator are included in TI 201A

  10. Proposed Energy Provisions of the California Green Building Standards Code

    E-Print Network [OSTI]

    Proposed Energy Provisions of the California Green Building Standards Code Part 11 of the California Building Code (also known as CalGreen) Patrick Saxton, P.E. patrick.saxton@energy.ca.gov 916-651-0489 High Performance Buildings and Standards Development Office California Energy Commission September 20

  11. Standard Energy Efficiency Data (SEED) Platform Homepage Screenshot

    Broader source: Energy.gov [DOE]

    The Standard Energy Efficiency Data (SEED) Platform™ is an open source software application that helps organizations easily manage data on the energy performance of large groups of buildings. This is a screenshot of the application homepage.

  12. Dynamic Simulation Studies of the Frequency Response of the Three U.S. Interconnections with Increased Wind Generation

    E-Print Network [OSTI]

    Mackin, Peter

    2011-01-01T23:59:59.000Z

    Performance of Wind Power Generation Working Group. ” IECwith Increased Wind Generation 9. Siemens Power Technologiesit Relates to Wind-Powered Generation. LBNL-XXXX. Berkeley:

  13. Understanding and Managing Generation Y

    E-Print Network [OSTI]

    Wallace, Kevin

    2007-12-14T23:59:59.000Z

    There are four generations in the workplace today; they consist of the Silent Generation, Baby Boom Generation, Generation X, and Generation Y. Generation Y, being the newest generation, is the least understood generation although marketers...

  14. Field Theory and Standard Model

    E-Print Network [OSTI]

    W. Buchmüller; C. Lüdeling

    2006-09-18T23:59:59.000Z

    This is a short introduction to the Standard Model and the underlying concepts of quantum field theory.

  15. TECHNICAL STANDARDS PROGRAM TOPICAL COMMITTEES

    Broader source: Energy.gov [DOE]

    PurposeThis procedure describes how topical committees are organized and recognized under the Technical Standards Program. 

  16. Performance Demonstration Program Management Plan

    SciTech Connect (OSTI)

    Carlsbad Field Office

    2005-07-01T23:59:59.000Z

    To demonstrate compliance with the Waste Isolation Pilot Plant (WIPP) waste characterization program, each testing and analytical facility performing waste characterization activities participates in the Performance Demonstration Program (PDP). The PDP serves as a quality control check against expected results and provides information about the quality of data generated in the characterization of waste destined for WIPP. Single blind audit samples are prepared and distributed by an independent organization to each of the facilities participating in the PDP. There are three elements within the PDP: analysis of simulated headspace gases, analysis of solids for Resource Conservation and Recovery Act (RCRA) constituents, and analysis for transuranic (TRU) radionuclides using nondestructive assay (NDA) techniques. Because the analysis for TRU radionuclides using NDA techniques involves both the counting of drums and standard waste boxes, four PDP plans are required to describe the activities of the three PDP elements. In accordance with these PDP plans, the reviewing and approving authority for PDP results and for the overall program is the CBFO PDP Appointee. The CBFO PDP Appointee is responsible for ensuring the implementation of each of these plans by concurring with the designation of the Program Coordinator and by providing technical oversight and coordination for the program. The Program Coordinator will designate the PDP Manager, who will coordinate the three elements of the PDP. The purpose of this management plan is to identify how the requirements applicable to the PDP are implemented during the management and coordination of PDP activities. The other participants in the program (organizations that perform site implementation and activities under CBFO contracts or interoffice work orders) are not covered under this management plan. Those activities are governed by the organization’s quality assurance (QA) program and procedures or as otherwise directed by CBFO.

  17. The Question The Standard Construction

    E-Print Network [OSTI]

    Raghavan, Dilip

    The Question The Standard Construction The ZFC construction Bibliography Solution to a Problem Construction The ZFC construction Bibliography Outline 1 The Question 2 The Standard Construction 3 The ZFC construction Dilip Raghavan Solution to a Problem of Van Douwen #12;The Question The Standard Construction

  18. 2008 BUILDING ENERGY EFFICIENCY STANDARDS

    E-Print Network [OSTI]

    2008 BUILDING ENERGY EFFICIENCY STANDARDS C A L I F O R N I A E N E RGY CO M M I S S I O N Buildings and Appliances Office #12;Acknowledgments The Building Energy Efficiency Standards (Standards and consultants. Valerie Hall, Deputy Director of the Energy Efficiency and Renewable Division provided policy

  19. Automated saturated standard cell intercomparison

    SciTech Connect (OSTI)

    Bell, B.E.; Deitesfeld, C.A. (ed.) ed.

    1987-10-05T23:59:59.000Z

    A cost effective, highly efficient, and automatic method of intercomparing standard cells has been sought after and implemented, utilizing computer control and a commercially available scanner. This system reduces intercomparison time from 4 hours to 30 minutes using the standard National Bureau of Standard (NBS) 4 x 4 design. 7 figs., 1 tab.

  20. Energy Codes and Standards: Facilities

    SciTech Connect (OSTI)

    Bartlett, Rosemarie; Halverson, Mark A.; Shankle, Diana L.

    2007-01-01T23:59:59.000Z

    Energy codes and standards play a vital role in the marketplace by setting minimum requirements for energy-efficient design and construction. They outline uniform requirements for new buildings as well as additions and renovations. This article covers basic knowledge of codes and standards; development processes of each; adoption, implementation, and enforcement of energy codes and standards; and voluntary energy efficiency programs.

  1. TOWARDS INTERNATIONAL STANDARDS FOR LANGUAGE

    E-Print Network [OSTI]

    Ide, Nancy

    ) developed by the International Standards Organization TC32 SC4, which is to serve as a basis for harmonizing. It is in this context that a committee of the International Standards Organization (ISO), TC 37/SC 4Chapter # TOWARDS INTERNATIONAL STANDARDS FOR LANGUAGE RESOURCES Nancy Ide and Laurent Romary

  2. Search for the Standard Model Higgs Boson in the Lepton + Missing Transverse Energy + Jets Final State in ATLAS

    E-Print Network [OSTI]

    Mark S. Neubauer; for the ATLAS Collaboration

    2011-10-11T23:59:59.000Z

    A search for the Standard Model Higgs boson has been performed in the H \\rightarrow WW \\rightarrow l{\

  3. Performance evaluation of bound diamond ring tools

    SciTech Connect (OSTI)

    Piscotty, M.A.; Taylor, J.S.; Blaedel, K.L.

    1995-07-14T23:59:59.000Z

    LLNL is collaborating with the Center for Optics Manufacturing (COM) and the American Precision Optics Manufacturers Association (APOMA) to optimize bound diamond ring tools for the spherical generation of high quality optical surfaces. An important element of this work is establishing an experimentally-verified link between tooling properties and workpiece quality indicators such as roughness, subsurface damage and removal rate. In this paper, we report on a standardized methodology for assessing ring tool performance and its preliminary application to a set of commercially-available wheels. Our goals are to (1) assist optics manufacturers (users of the ring tools) in evaluating tools and in assessing their applicability for a given operation, and (2) provide performance feedback to wheel manufacturers to help optimize tooling for the optics industry. Our paper includes measurements of wheel performance for three 2-4 micron diamond bronze-bond wheels that were supplied by different manufacturers to nominally- identical specifications. Preliminary data suggests that the difference in performance levels among the wheels were small.

  4. HOGEN{trademark} proton exchange membrane hydrogen generators: Commercialization of PEM electrolyzers

    SciTech Connect (OSTI)

    Smith, W.F.; Molter, T.M. [Proton Energy Systems, Inc., Rocky Hill, CT (United States)

    1997-12-31T23:59:59.000Z

    PROTON Energy Systems` new HOGEN series hydrogen generators are Proton Exchange Membrane (PEM) based water electrolyzers designed to generate 300 to 1000 Standard Cubic Feet Per Hour (SCFH) of high purity hydrogen at pressures up to 400 psi without the use of mechanical compressors. This paper will describe technology evolution leading to the HOGEN, identify system design performance parameters and describe the physical packaging and interfaces of HOGEN systems. PEM electrolyzers have served US and UK Navy and NASA needs for many years in a variety of diverse programs including oxygen generators for life support applications. In the late 1970`s these systems were advocated for bulk hydrogen generation through a series of DOE sponsored program activities. During the military buildup of the 1980`s commercial deployment of PEM hydrogen generators was de-emphasized as priority was given to new Navy and NASA PEM electrolysis systems. PROTON Energy Systems was founded in 1996 with the primary corporate mission of commercializing PEM hydrogen generators. These systems are specifically designed and priced to meet the needs of commercial markets and produced through manufacturing processes tailored to these applications. The HOGEN series generators are the first step along the path to full commercial deployment of PEM electrolyzer products for both industrial and consumer uses. The 300/1000 series are sized to meet the needs of the industrial gases market today and provide a design base that can transition to serve the needs of a decentralized hydrogen infrastructure tomorrow.

  5. Searches for Fourth Generation Fermions

    E-Print Network [OSTI]

    A. Ivanov for CDF; D0 Collaborations

    2011-09-07T23:59:59.000Z

    We present the results from searches for fourth generation fermions performed using data samples collected by the CDF II and D0 Detectors at the Fermilab Tevatron ppbar collider. Many of these results represent the most stringent 95% C.L. limits on masses of new fermions to-date.

  6. Performance Monitoring

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Optimization Performance Monitoring Performance Monitoring A redirector page has been set up without anywhere to redirect to. Last edited: 2014-08-25 14:37:27...

  7. ARM Standards Policy Committee Report

    SciTech Connect (OSTI)

    Cialella, A; Jensen, M; Koontz, A; McFarlane, S; McCoy, R; Monroe, J; Palanisamy, G; Perez, R; Sivaraman, C

    2012-09-19T23:59:59.000Z

    Data and metadata standards promote the consistent recording of information and are necessary to ensure the stability and high quality of Atmospheric Radiation Measurement (ARM) Climate Research Facility data products for scientific users. Standards also enable automated routines to be developed to examine data, which leads to more efficient operations and assessment of data quality. Although ARM Infrastructure agrees on the utility of data and metadata standards, there is significant confusion over the existing standards and the process for allowing the release of new data products with exceptions to the standards. The ARM Standards Policy Committee was initiated in March 2012 to develop a set of policies and best practices for ARM data and metadata standards.

  8. Standards Panel: 1. Stephen Diamond, General Manager, Industry Standards Office and Global Standards Officer, EMC

    E-Print Network [OSTI]

    Standards Officer, EMC Corporation, Office of the CTO Steve Diamond has 30 years of management, marketing was President of the IEEE Computer Society. Steve is General Manager of the Industry Standards Office at EMC Corporation, and Global Standards Officer in the Office of the CTO. Before EMC, he was responsible for cloud

  9. The Lepton Sector of a Fourth Generation

    E-Print Network [OSTI]

    Gustavo Burdman; Leandro Da Rold; Ricardo D. Matheus

    2010-05-10T23:59:59.000Z

    In extensions of the standard model with a heavy fourth generation one important question is what makes the fourth-generation lepton sector, particularly the neutrinos, so different from the lighter three generations. We study this question in the context of models of electroweak symmetry breaking in warped extra dimensions, where the flavor hierarchy is generated by the localization of the zero-mode fermions in the extra dimension. In this setup the Higgs sector is localized near the infrared brane, whereas the Majorana mass term is localized at the ultraviolet brane. As a result, light neutrinos are almost entirely Majorana particles, whereas the fourth generation neutrino is mostly a Dirac fermion. We show that it is possible to obtain heavy fourth-generation leptons in regions of parameter space where the light neutrino masses and mixings are compatible with observation. We study the impact of these bounds, as well as the ones from lepton flavor violation, on the phenomenology of these models.

  10. USE OF VOLUNTARY CONSENSUS STANDARDS AND INTERACTION WITH STANDARDS...

    Energy Savers [EERE]

    DEVELOPMENT ORGANIZATIONS Purpose This procedure identifies the process by which DOE adopts Voluntary Consensus Standards (VCSs) and provides guidance for the interaction...

  11. The standards forum: Volume 6, Number 3 -- December 1998

    SciTech Connect (OSTI)

    NONE

    1998-12-01T23:59:59.000Z

    This issue contains the following articles: NIST--A call for a national standards strategy; Fourth integrated safety management lessons learned workshop; TSP [Technical Standards Program] publications support moves to headquarters; Comments on the role of the federal government in environmental technology development; Technical standards manager spotlight; Topical committee developments: Quality assurance topical committee plays an active role in the TSP, New DOE accreditation committee targets issues and resolutions at first annual meeting, DOE fire safety committee meeting in New Orleans, Third annual DOE metrology committee meeting coming in March 1999, The biota dose assessment committee providing a major forum and technical resource for DOE, and A performance-based management handbook in the works; DOE technical standards projects initiated; Recently published DOE documents; Non-government standards: American National Standards Institute and American Society for Testing and Materials; Most DOE comments on ISO 17025 upheld by ANSI review committee; and ISO 9000 compliance--Changes in the future.

  12. Hedging Quantity Risks with Standard Power Options in a Competitive Wholesale Electricity Market

    E-Print Network [OSTI]

    Oren, Shmuel S.

    Hedging Quantity Risks with Standard Power Options in a Competitive Wholesale Electricity Market the generation, transmission, and distribution and introduced competition in generation, wholesale procure- ment in the wholesale market by numerous market participants such as generators, load- serving entities (LSEs

  13. Waste generator services implementation plan

    SciTech Connect (OSTI)

    Mousseau, J.; Magleby, M.; Litus, M.

    1998-04-01T23:59:59.000Z

    Recurring waste management noncompliance problems have spurred a fundamental site-wide process revision to characterize and disposition wastes at the Idaho National Engineering and Environmental Laboratory. The reengineered method, termed Waste Generator Services, will streamline the waste acceptance process and provide waste generators comprehensive waste management services through a single, accountable organization to manage and disposition wastes in a timely, cost-effective, and compliant manner. This report outlines the strategy for implementing Waste Generator Services across the INEEL. It documents the culmination of efforts worked by the LMITCO Environmental Management Compliance Reengineering project team since October 1997. These efforts have included defining problems associated with the INEEL waste management process; identifying commercial best management practices; completing a review of DOE Complex-wide waste management training requirements; and involving others through an Integrated Process Team approach to provide recommendations on process flow, funding/charging mechanisms, and WGS organization. The report defines the work that will be performed by Waste Generator Services, the organization and resources, the waste acceptance process flow, the funding approach, methods for measuring performance, and the implementation schedule and approach. Field deployment will occur first at the Idaho Chemical Processing Plant in June 1998. Beginning in Fiscal Year 1999, Waste Generator Services will be deployed at the other major INEEL facilities in a phased approach, with implementation completed by March 1999.

  14. Generation gaps in engineering?

    E-Print Network [OSTI]

    Kim, David J. (David Jinwoo)

    2008-01-01T23:59:59.000Z

    There is much enthusiastic debate on the topic of generation gaps in the workplace today; what the generational differences are, how to address the apparent challenges, and if the generations themselves are even real. ...

  15. web identity standards introduction .............................................................................................................87

    E-Print Network [OSTI]

    Mullins, Dyche

    web identity standards sectionten 86 contents introduction............................................................................................................... 89-90 tagline and the web .................................................................................................91 tagline and the web: improper use

  16. Emission Standards for Contaminants (Iowa)

    Broader source: Energy.gov [DOE]

    These regulations list emissions standards for various contaminants, and contain special requirements for anaerobic lagoons. These regulations also describe alternative emissions limits, which may...

  17. Surface Water Quality Standards (Nebraska)

    Broader source: Energy.gov [DOE]

    These regulations, promulgated by the Department of Environmental Quality, contain surface water quality standards, stream classifications, discussion of lakes and impounded basins, and water...

  18. The Standards Forum, June 2001

    Broader source: Energy.gov (indexed) [DOE]

    technical standards then be- ing developed and used by DOE often lacked a consis- tent, high quality technical and administrative basis and were often marginally needed. Initiation...

  19. Effluent and Pretreatment Standards (Iowa)

    Broader source: Energy.gov [DOE]

    These regulations describe prohibited discharges into surface water and groundwater systems and set effluent standards for secondary treatment facilities. Effluent limitations and pretreatment...

  20. The Standards Forum, December 1999

    Broader source: Energy.gov (indexed) [DOE]

    Guide for Specifying and Selecting Power, Control and Special Purpose Cable for Petroleum and Chemical Plants (new standard) - October 26, 1999. ANSINFPA 11A-1998,...

  1. Ambient Air Quality Standards (Iowa)

    Broader source: Energy.gov [DOE]

    These regulations set statewide ambient air quality standards for various contaminants. The state code follows the regulations set forth in the National Primary and Secondary Ambient Air Quality...

  2. International Quality Assurance Standards (Presentation)

    SciTech Connect (OSTI)

    Kurtz, S.; Hacke, P.; Wohlgemuth, J.; Kempe, M.; Yamamichi, M.

    2011-02-01T23:59:59.000Z

    Tests to make quantitative predictions about photovoltaic (PV) modules are needed. This presentation proposes the creation of international quality assurance standards for PV modules.

  3. Standard and non standard ideas for the Higgs boson sector

    E-Print Network [OSTI]

    Abbondandolo, Alberto

    Standard and non standard ideas for the Higgs boson sector Riccardo Barbieri Johns Hopkins Workshop as the Higgs boson is in their low-energy spectrum We only know of approximate symmetries that can explain synoptic table Supersymmetric The SM Higgs boson TC-like Minimally extended Higgsless "Composite" 5

  4. Dubuque generation station, Dubuque, Iowa

    SciTech Connect (OSTI)

    Peltier, R.

    2008-10-15T23:59:59.000Z

    Alliant Energy's Dubuque generation station is a fine example of why small does not mean insignificant in the power generation industry. This winner of the EUCG best performer award in the small plant category shows that its operating excellence towers over that of many larger and much newer coal-fired power plants. The plant has three operating units with boilers originally designed for Illinois basin coal but now Powder River Basin coal makes up 75% of the coal consumed. The boilers can also burn natural gas. 4 photos.

  5. Development of a high-performance coal-fired power generating system with pyrolysis gas and char-fired high temperature furnace (HITAF). Quarterly progress report No. 7, July--September 1993

    SciTech Connect (OSTI)

    Not Available

    1993-11-01T23:59:59.000Z

    A concept for an advanced coal-fired combined-cycle power generating system is currently being developed. The first phase of this three-phase program consists of conducting the necessary research and development to define the system, evaluating the economic and technical feasibility of the concept, and preparing an R&D plan to develop the concept further. Foster Wheeler Development Corporation (FWDC) is leading a team of companies involved in this effort. The power generating system being developed in this project will be an improvement over current coal-fired systems. Goals have been specified that relate to the efficiency, emissions, costs, and general operation of the system. The system proposed to meet these goals is a combined-cycle system where air for a gas turbine is indirectly heated to approximately 1800{degrees}F in furnaces fired with coal-derived fuels and then directly heated in a natural-gas-fired combustor to about 2400{degrees}F. The system is based on a pyrolyzing process that converts the coal into a low-Btu fuel gas and char. The fuel gas is relatively clean, and it is fired to heat tube surfaces that are susceptible to corrosion and problems from ash deposition. In particular, the high-temperature air heater tubes, which will need to be a ceramic material, will be located in a separate furnace or region of a furnace that is exposed to combustion products from the low-Btu fuel gas only. A simplified process flow diagram is shown in Figure 1.

  6. Small Generator Aggregation (Maine)

    Broader source: Energy.gov [DOE]

    This section establishes requirements for electricity providers to purchase electricity from small generators, with the goal of ensuring that small electricity generators (those with a nameplate...

  7. Project Profile: Development and Performance Evaluation of High...

    Energy Savers [EERE]

    Development and Performance Evaluation of High Temperature Concrete for Thermal Energy Storage for Solar Power Generation Project Profile: Development and Performance Evaluation of...

  8. The Chemistry of Flammable Gas Generation

    SciTech Connect (OSTI)

    ZACH, J.J.

    2000-10-30T23:59:59.000Z

    The document collects information from field instrumentation, laboratory tests, and analytical models to provide a single source of information on the chemistry of flammable gas generation at the Hanford Site. It considers the 3 mechanisms of formation: radiolysis, chemical reactions, and thermal generation. An assessment of the current models for gas generation is then performed. The results are that the various phenomena are reasonably understood and modeled compared to field data.

  9. Options for Control of Reactive Power by Distributed Photovoltaic Generators

    E-Print Network [OSTI]

    Petr Sulc; Konstantin Turitsyn; Scott Backhaus; Michael Chertkov

    2010-08-04T23:59:59.000Z

    High penetration levels of distributed photovoltaic(PV) generation on an electrical distribution circuit present several challenges and opportunities for distribution utilities. Rapidly varying irradiance conditions may cause voltage sags and swells that cannot be compensated by slowly responding utility equipment resulting in a degradation of power quality. Although not permitted under current standards for interconnection of distributed generation, fast-reacting, VAR-capable PV inverters may provide the necessary reactive power injection or consumption to maintain voltage regulation under difficult transient conditions. As side benefit, the control of reactive power injection at each PV inverter provides an opportunity and a new tool for distribution utilities to optimize the performance of distribution circuits, e.g. by minimizing thermal losses. We discuss and compare via simulation various design options for control systems to manage the reactive power generated by these inverters. An important design decision that weighs on the speed and quality of communication required is whether the control should be centralized or distributed (i.e. local). In general, we find that local control schemes are capable for maintaining voltage within acceptable bounds. We consider the benefits of choosing different local variables on which to control and how the control system can be continuously tuned between robust voltage control, suitable for daytime operation when circuit conditions can change rapidly, and loss minimization better suited for nighttime operation.

  10. Performative architecture

    E-Print Network [OSTI]

    Araya, Sergio (Sergio Alejandro)

    2011-01-01T23:59:59.000Z

    The following thesis explores two central hypotheses. On the one hand it introduces the idea of performative architecture (performance in design), and has done so with the desire to contribute directly to the expansion of ...

  11. LATTICE POINT GENERATING FUNCTIONS AND SYMMETRIC CONES

    E-Print Network [OSTI]

    Savage, Carla D.

    LATTICE POINT GENERATING FUNCTIONS AND SYMMETRIC CONES MATTHIAS BECK, THOMAS BLIEM, BENJAMIN BRAUN Sn . Specifically, [3] discusses various approaches to compute, for a fixed set of parame- ters a1, a representation of Sn, a = (a1, . . . , an), and ( , ) is the standard inner product on Rn . This viewpoint

  12. EPA's Radiation Protection Standards Protecting the Environment from

    E-Print Network [OSTI]

    (transuranic wastes). The standards apply to the management, storage and disposal of spent nuclear fuel, conversion, fabrication, use and processing of uranium fuel for generating electrical power. · Spent Nuclear Fuel, High Level, and Transuranic Wastes: EPA's Management and Storage of Spent Fuel, High Level

  13. Comparing the Costs of Intermittent and Dispatchable Electricity Generating Technologies

    E-Print Network [OSTI]

    Joskow, Paul L.

    Economic evaluations of alternative electric generating technologies typically rely on comparisons between their expected life-cycle production costs per unit of electricity supplied. The standard life-cycle cost metric ...

  14. Feasibility Study of Economics and Performance of Geothermal Power Generation at the Lakeview Uranium Mill Site in Lakeview, Oregon. A Study Prepared in Partnership with the Environmental Protection Agency for the RE-Powering America's Land Initiative: Siting Renewable Energy on Potentially Contaminated Land and Mine Sites

    SciTech Connect (OSTI)

    Hillesheim, M.; Mosey, G.

    2013-11-01T23:59:59.000Z

    The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the Lakeview Uranium Mill site in Lakeview, Oregon, for a feasibility study of renewable energy production. The EPA contracted with the National Renewable Energy Laboratory (NREL) to provide technical assistance for the project. The purpose of this report is to describe an assessment of the site for possible development of a geothermal power generation facility and to estimate the cost, performance, and site impacts for the facility. In addition, the report recommends development pathways that could assist in the implementation of a geothermal power system at the site.

  15. Portland State University Identity Standards

    E-Print Network [OSTI]

    Bertini, Robert L.

    Portland State University Identity Standards #12;3 Introduction 4 Key Messages 5 Identity Basics 8 for applying a consistent look, feel, voice, and tone for all Portland State University communications. Graphic identity standards enhance communication with our constituents. They distinguish Portland State from other

  16. A better renewable portfolio standard

    SciTech Connect (OSTI)

    Casten, Sean

    2009-06-15T23:59:59.000Z

    It's time to throw out our RPS, throw out our Energy Efficiency Resource Standard, throw out all our definitions of eligible technologies, and replace them all with a single, clear incentive paid to any power plant that reduces our demand for fossil resources, pro rata with the fossil energy reduction: a Fossil Energy Reduction Standard. (author)

  17. STANDARD OPERATING PROCEDURES Site Selection

    E-Print Network [OSTI]

    Fischer, Emily V.

    IMPROVE STANDARD OPERATING PROCEDURES SOP 126 Site Selection Date Last Modified Modified by: 09 References none #12;SOP 126: Site Selection 3 1.0 PURPOSE AND APPLICABILITY This standard operating procedure field conditions, and for ease of operation and maintenance. IMPROVE aerosol samplers are generally

  18. Standards for Power Electronic Components

    E-Print Network [OSTI]

    Standards for Power Electronic Components and Systems EPE 14 ECCE Europe Dr Peter R. Wilson #12;Session Outline · "Standards for Power Electronic Components and Systems" ­ Peter Wilson, IEEE PELS Electronics ­ where next? · Wide Band Gap Devices ­ SiC, GaN etc... · Transformers (ETTT) · Power Modules

  19. Generation to Generation: The Heart of Family Medicine

    E-Print Network [OSTI]

    Winter, Robin O

    2012-01-01T23:59:59.000Z

    Ageism in the Workplace. Generations Spring, 5. Westman,of caring for multiple generations simultaneously. StronglyGeneration to Generation: The Heart of Family Medicine

  20. Performance of the Southern California Edison Company Stirling dish

    SciTech Connect (OSTI)

    Lopez, C.W. [Southern California Edison Co., Rosemead, CA (United States); Stone, K.W. [Mako Enterprises, Huntington Beach, CA (United States)

    1993-10-01T23:59:59.000Z

    McDonnell Douglas Astronautics Company (MDAC) and United Stirling AB of Sweden (USAB) formed a joint venture in 1982 to develop and produce a Stirling dish solar generating system. In this report, the six year development and testing program continued by the Southern California Edison Company (SCE) is described. Each Stirling dish module consists of a sun tracking dish concentrator developed by the MDAC and a Stirling engine driven power conversion unit (PCU) developed by USAB. The Stirling dish system demonstrated twice the peak and daily solar-to-electric conversion efficiency of any other system then under development. This system continues to set the performance standard for solar to electric systems being developed in the early 1990`s. Test data are presented and used to estimate the performance of a commercial system.

  1. Gamma ray generator

    DOE Patents [OSTI]

    Firestone, Richard B; Reijonen, Jani

    2014-05-27T23:59:59.000Z

    An embodiment of a gamma ray generator includes a neutron generator and a moderator. The moderator is coupled to the neutron generator. The moderator includes a neutron capture material. In operation, the neutron generator produces neutrons and the neutron capture material captures at least some of the neutrons to produces gamma rays. An application of the gamma ray generator is as a source of gamma rays for calibration of gamma ray detectors.

  2. DOE standard: Integration of environment, safety, and health into facility disposition activities. Volume 1: Technical standard

    SciTech Connect (OSTI)

    NONE

    1998-05-01T23:59:59.000Z

    This Department of Energy (DOE) technical standard (referred to as the Standard) provides guidance for integrating and enhancing worker, public, and environmental protection during facility disposition activities. It provides environment, safety, and health (ES and H) guidance to supplement the project management requirements and associated guidelines contained within DOE O 430.1A, Life-Cycle Asset Management (LCAM), and amplified within the corresponding implementation guides. In addition, the Standard is designed to support an Integrated Safety Management System (ISMS), consistent with the guiding principles and core functions contained in DOE P 450.4, Safety Management System Policy, and discussed in DOE G 450.4-1, Integrated Safety Management System Guide. The ISMS guiding principles represent the fundamental policies that guide the safe accomplishment of work and include: (1) line management responsibility for safety; (2) clear roles and responsibilities; (3) competence commensurate with responsibilities; (4) balanced priorities; (5) identification of safety standards and requirements; (6) hazard controls tailored to work being performed; and (7) operations authorization. This Standard specifically addresses the implementation of the above ISMS principles four through seven, as applied to facility disposition activities.

  3. Appliance Standards and Rulemaking Federal Advisory Committee...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Issuance Appliance Standards and Rulemaking Federal Advisory Committee (ASRAC) - Central Air Conditioner Regional Standards Enforcement Working Group; Notice of Open...

  4. Standard Review Plan Update and Development Program

    SciTech Connect (OSTI)

    Not Available

    1992-05-01T23:59:59.000Z

    This implementing procedures document (IPD) was prepared for use in implementing tasks under the standard review plan update and development program (SRP-UDP). The IPD provides comprehensive guidance and detailed procedures for SRP-UDP tasks. The IPD is mandatory for contractors performing work for the SRP-UDP. It is guidance for the staff. At the completion of the SRP-UDP, the IPD will be revised (to remove the UDP aspects) and will replace NRR Office Letter No. 800 as long-term maintenance procedures.

  5. Performance Characterization

    Broader source: Energy.gov [DOE]

    Performance characterization efforts within the SunShot Systems Integration activities focus on collaborations with U.S. solar companies to:

  6. Developing Human Performance Measures

    SciTech Connect (OSTI)

    Jeffrey Joe; Bruce Hallbert; Larry Blackwood; Donald Dudehoeffer; Kent Hansen

    2006-05-01T23:59:59.000Z

    Through the reactor oversight process (ROP), the U.S. Nuclear Regulatory Commission (NRC) monitors the performance of utilities licensed to operate nuclear power plants. The process is designed to assure public health and safety by providing reasonable assurance that licensees are meeting the cornerstones of safety and designated crosscutting elements. The reactor inspection program, together with performance indicators (PIs), and enforcement activities form the basis for the NRC’s risk-informed, performance based regulatory framework. While human performance is a key component in the safe operation of nuclear power plants and is a designated cross-cutting element of the ROP, there is currently no direct inspection or performance indicator for assessing human performance. Rather, when human performance is identified as a substantive cross cutting element in any 1 of 3 categories (resources, organizational or personnel), it is then evaluated for common themes to determine if follow-up actions are warranted. However, variability in human performance occurs from day to day, across activities that vary in complexity, and workgroups, contributing to the uncertainty in the outcomes of performance. While some variability in human performance may be random, much of the variability may be attributed to factors that are not currently assessed. There is a need to identify and assess aspects of human performance that relate to plant safety and to develop measures that can be used to successfully assure licensee performance and indicate when additional investigation may be required. This paper presents research that establishes a technical basis for developing human performance measures. In particular, we discuss: 1) how historical data already gives some indication of connection between human performance and overall plant performance, 2) how industry led efforts to measure and model human performance and organizational factors could serve as a data source and basis for a framework, 3) how our use of modeling and simulation techniques could be used to develop and validate measures of human performance, and 4) what the possible outcomes are from this research as the modeling and simulation efforts generate results.

  7. CANDU human performance analysis

    SciTech Connect (OSTI)

    Walker, I.

    1987-01-01T23:59:59.000Z

    An evaluation of human performance is presented in this paper in the context of the operational safety management system. To focus on problems, an experience review program has been developed to establish trends, demonstrate the degree of compliance with standards, and determine the causes of poor performance. The primary method by which the experience review takes place is significant event reporting (SER). A significant event is an incident that causes an undesirable effect on safety, product quality, environmental protection, or product cost. In spite of advanced technology and the degree of automation of the Canada deuterium uranium (CANDU) design, mistakes and malfunctions to occur. Considerable effort has been made to prevent or reduce the incidence of error. The Institute of Nuclear Power Operations developed a system to analyze human error, called the Human Performance Evaluation System (HPES). To encourage an open exchange of information, the system is anonymous and nonpunitive. All data gathered during HPES evaluations are kept confidential.

  8. Lorentz conserving noncommutative standard model

    SciTech Connect (OSTI)

    Ettefaghi, M. M.; Haghighat, M. [Department of Physics, Isfahan University of Technology, Isfahan (Iran, Islamic Republic of)

    2007-06-15T23:59:59.000Z

    We consider Lorentz-conserving noncommutative field theory to construct the Lorentz-conserving noncommutative standard model based on the gauge group SU(3)xSU(2)xU(1). We obtain the enveloping algebra-valued of Higgs field up to the second order of the noncommutativity parameter {theta}{sub {mu}}{sub {nu}}. We derive the action at the leading order and find new vertices which are absent in the ordinary standard model as well as the minimal noncommutative standard model. We briefly study the phenomenological aspects of the model.

  9. Status of ASCE Standard on Design and Construction of Frost Protected Shallow Foundations1

    E-Print Network [OSTI]

    Horvath, John S.

    by a standard test provides no inherent, fundamental insight into creep behavior of the geofoam. As discussed subsequently, geofoam creep is a very important consideration. Other relevant aspects of a standard test, the more-or-less standard test used worldwide to determine compressive strength is performed

  10. September 2013 Most Viewed Documents for Power Generation And...

    Office of Scientific and Technical Information (OSTI)

    Gas Turbine Exhaust Diffuser Norris, Thomas R. (2009) 23 > Dynamic performance and control of a static var generator using cascade multilevel inverters Peng, Fang Zheng...

  11. Development of a 100-Watt High Temperature Thermoelectric Generator

    Broader source: Energy.gov (indexed) [DOE]

    performance TEG thermal and electrical interfaces modified to withstand high temperature environment Development of a 100 watt High Temperature TE Generator DEER 2008 11 Prototype...

  12. High Performance Fortran: An overview

    SciTech Connect (OSTI)

    Zosel, M.E.

    1992-12-23T23:59:59.000Z

    The purpose of this paper is to give an overview of the work of the High Performance Fortran Forum (HPFF). This group of industry, academic, and user representatives has been meeting to define a set of extensions for Fortran dedicated to the special problems posed by a very high performance computers, especially the new generation of parallel computers. The paper describes the HPFF effort and its goals and gives a brief description of the functionality of High Performance Fortran (HPF).

  13. Cylindrical neutron generator

    DOE Patents [OSTI]

    Leung, Ka-Ngo (Hercules, CA)

    2008-04-22T23:59:59.000Z

    A cylindrical neutron generator is formed with a coaxial RF-driven plasma ion source and target. A deuterium (or deuterium and tritium) plasma is produced by RF excitation in a cylindrical plasma ion generator using an RF antenna. A cylindrical neutron generating target is coaxial with the ion generator, separated by plasma and extraction electrodes which contain many slots. The plasma generator emanates ions radially over 360.degree. and the cylindrical target is thus irradiated by ions over its entire circumference. The plasma generator and target may be as long as desired. The plasma generator may be in the center and the neutron target on the outside, or the plasma generator may be on the outside and the target on the inside. In a nested configuration, several concentric targets and plasma generating regions are nested to increase the neutron flux.

  14. Cylindrical neutron generator

    DOE Patents [OSTI]

    Leung, Ka-Ngo (Hercules, CA)

    2009-12-29T23:59:59.000Z

    A cylindrical neutron generator is formed with a coaxial RF-driven plasma ion source and target. A deuterium (or deuterium and tritium) plasma is produced by RF excitation in a cylindrical plasma ion generator using an RF antenna. A cylindrical neutron generating target is coaxial with the ion generator, separated by plasma and extraction electrodes which contain many slots. The plasma generator emanates ions radially over 360.degree. and the cylindrical target is thus irradiated by ions over its entire circumference. The plasma generator and target may be as long as desired. The plasma generator may be in the center and the neutron target on the outside, or the plasma generator may be on the outside and the target on the inside. In a nested configuration, several concentric targets and plasma generating regions are nested to increase the neutron flux.

  15. Cylindrical neutron generator

    DOE Patents [OSTI]

    Leung, Ka-Ngo

    2005-06-14T23:59:59.000Z

    A cylindrical neutron generator is formed with a coaxial RF-driven plasma ion source and target. A deuterium (or deuterium and tritium) plasma is produced by RF excitation in a cylindrical plasma ion generator using an RF antenna. A cylindrical neutron generating target is coaxial with the ion generator, separated by plasma and extraction electrodes which contain many slots. The plasma generator emanates ions radially over 360.degree. and the cylindrical target is thus irradiated by ions over its entire circumference. The plasma generator and target may be as long as desired. The plasma generator may be in the center and the neutron target on the outside, or the plasma generator may be on the outside and the target on the inside. In a nested configuration, several concentric targets and plasma generating regions are nested to increase the neutron flux.

  16. Horizontal Steam Generator Thermal-Hydraulics at Various Steady-State Power Levels

    SciTech Connect (OSTI)

    Stevanovic, Vladimir D. [University of Belgrade, Kraljice Marije 16, 11000 Belgrade, Serbia and Montenegro (Yugoslavia); Stosic, Zoran V.; Kiera, Michael; Stoll, Uwe [Framatome ANP GmbH, P.O. Box 3220, 91050 Erlangen (Germany)

    2002-07-01T23:59:59.000Z

    Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with {sup c}losure laws{sup .} Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been extended in order to take into account the 3D flow of liquid and gas phase. The methodology is validated by comparing numerical and experimental results of real steam generator operational conditions at various power levels of the WWER Novovoronezh, Unit 5. One-dimensional model of the horizontal steam generator has been built with the RELAP 5 standard code on the basis of the multidimensional two-phase flow structure obtained with the 3D ANA code. RELAP 5 and 3D ANA code results are compared, showing acceptable agreement. (authors)

  17. Minimum Stream Flow Standards (Connecticut)

    Broader source: Energy.gov [DOE]

    These regulations apply to all dams and structures which impound or divert waters on rivers or their tributaries, with some exceptions. The regulations set standards for minimum flow (listed in the...

  18. Minimum Gas Service Standards (Ohio)

    Broader source: Energy.gov [DOE]

    Natural gas companies in Ohio are required to follow the Minimum Gas Service Standards, which are set and enforced by the Public Utilities Commission of Ohio. These rules are found in chapter 4901...

  19. Information Security Office Logging Standard

    E-Print Network [OSTI]

    Alpay, S. Pamir

    All Approvals Review Date Reviewed By Name/Title Action (Reviewed or Approved) 6/01/2013 CISO Jason Pufahl, CISO Approved 6/01/2013 RMAC Risk Management Advisory Council Reviewed #12;Logging Standard 2 | P

  20. Dam Safety Standards (New Jersey)

    Broader source: Energy.gov [DOE]

    These rules set forth procedures for application to construct, repair or modify a dam and set standards for design and maintenance of dams. These rules also establish a dam inspection procedure....

  1. International Standards in Forensic DNA

    E-Print Network [OSTI]

    acceptable or desirable · something set up and established by authority as a rule for the measure of quantity Laboratory Accreditation QAS Documentary Standards & SWGDAM Guidelines Validated Methods (using physical

  2. Mass Properties Testing and Evaluation for the Multi-Mission Radioisotope Thermoelectric Generator

    SciTech Connect (OSTI)

    Felicione, Frank S.

    2009-12-01T23:59:59.000Z

    Mass properties (MP) measurements were performed for the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG), serial number (S/N) 0X730401, the power system designated for the Mars Science Laboratory (MSL) mission. Measurements were made using new mounting fixtures at the mass properties testing station in the Idaho National Laboratory (INL) Space and Security Power Systems Facility (SSPSF). The objective of making mass properties measurements was to determine the generator’s flight configured mass and center of mass or center of gravity (CG). Using an extremely accurate platform scale, the mass of the as-tested generator was determined to be 100.117 ± 0.007 lb. Weight accuracy was determined by checking the platform scale with calibrated weights immediately prior to weighing the MMRTG.a CG measurement accuracy was assessed by surrogate testing using an inert mass standard for which the CG could be readily determined analytically. Repeated testing using the mass standard enabled the basic measurement precision of the system to be quantified in terms of a physical confidence interval about the measured CG position. However, repetitious testing with the MMRTG itself was not performed in deference to the gamma and neutron radiation dose to operators and the damage potential to the flight unit from extra handling operations. Since the mass standard had been specially designed to have a total weight and CG location that closely matched the MMRTG, the uncertainties determined from its testing were assigned to the MMRTG as well. On this basis, and at the 99% confidence level, a statistical analysis found the direct, as-measured MMRTG-MSL CG to be located at 10.816 ± 0.0011 in. measured perpendicular from the plane of the lower surface of the generator’s mounting lugs (Z direction), and offset from the generator’s long axis centerline in the X and Y directions by 0.0968 ± 0.0040 in. and 0.0276 ± 0.0026 in., respectively. These uncertainties are based simply on the statistical treatment of results from repetitive testing performed with the mass standard and included position variations that may have occurred during several mounting/dismounting operations of both the mass standard and mounting fixtures. Because of the limited data available, the computed uncertainty intervals reported are likely, although not assuredly, wider than the intervals that would have been found had more extensive data been available. However, these uncertainties do not account for other contributors to measurement uncertainty that might be applicable. These include potential weighing errors, possible tilt of the as-mounted test article, or translation of the measurement results from the MP instrument coordinates to those of the test article. Furthermore, when testing heat producing test articles such as the MMRTG, measurement degradation can occur from thermal expansion/contraction of the mounting fixtures as they heat up or cool and cause a subtle repositioning of the test article. Analyses for such impacts were made and additional uncertainty allowances were conservatively assigned to account for these. A full, detailed description is provided in this report.

  3. Laboratory Performance Evaluation Report of SEL 421 Phasor Measurement Unit

    SciTech Connect (OSTI)

    Huang, Zhenyu; faris, Anthony J.; Martin, Kenneth E.; Hauer, John F.; Bonebrake, Christopher A.; Shaw, James M.

    2007-12-01T23:59:59.000Z

    PNNL and BPA have been in close collaboration on laboratory performance evaluation of phasor measurement units for over ten years. A series of evaluation tests are designed to confirm accuracy and determine measurement performance under a variety of conditions that may be encountered in actual use. Ultimately the testing conducted should provide parameters that can be used to adjust all measurements to a standardized basis. These tests are performed with a standard relay test set using recorded files of precisely generated test signals. The test set provides test signals at a level and in a format suitable for input to a PMU that accurately reproduces the signals in both signal amplitude and timing. Test set outputs are checked to confirm the accuracy of the output signal. The recorded signals include both current and voltage waveforms and a digital timing track used to relate the PMU measured value with the test signal. Test signals include steady-state waveforms to test amplitude, phase, and frequency accuracy, modulated signals to determine measurement and rejection bands, and step tests to determine timing and response accuracy. Additional tests are included as necessary to fully describe the PMU operation. Testing is done with a BPA phasor data concentrator (PDC) which provides communication support and monitors data input for dropouts and data errors.

  4. Performance Engineering: Understanding and Improving the Performance of Large-Scale Codes

    E-Print Network [OSTI]

    2008-01-01T23:59:59.000Z

    An API for Runtime Code Patching,” Journal of Highof the Conference on Code Generation and Optimization,Performance of Large-Scale Codes David H. Bailey 1 , Robert

  5. ELEMENT POINT RANGES AND BENCHMARK PERFORMANCE STANDARDS TABLE THIS SHEET MUST BE USED IN CONJUNCTION WITH THE PERFORMANCE PLAN. THE BENCHMARK PERFORMANCE STANDARDS ARE USED TO EVALUATE AND

    E-Print Network [OSTI]

    technical knowledge/skill; Work did not meet minimum specifications; Routine problems were not resolved satisfactorily; Written and oral communication poor and not understandable; Exhibited uncooperative

  6. GridWise Standards Mapping Overview

    SciTech Connect (OSTI)

    Bosquet, Mia L.

    2004-04-01T23:59:59.000Z

    ''GridWise'' is a concept of how advanced communications, information and controls technology can transform the nation's energy system--across the spectrum of large scale, central generation to common consumer appliances and equipment--into a collaborative network, rich in the exchange of decision making information and an abundance of market-based opportunities (Widergren and Bosquet 2003) accompanying the electric transmission and distribution system fully into the information and telecommunication age. This report summarizes a broad review of standards efforts which are related to GridWise--those which could ultimately contribute significantly to advancements toward the GridWise vision, or those which represent today's current technological basis upon which this vision must build.

  7. Necessary and Sufficient Process leading to Work Smart Standards. Final report

    SciTech Connect (OSTI)

    NONE

    1996-11-01T23:59:59.000Z

    The Necessary and Sufficient Process leading to Work Smart Standards is a Department of Energy initiative to assure adequate protection for workers, the public, and the environment. The Work Smart Standards initiative directs the Laboratory to develop a set of ES and H standards based on the work performed at the Laboratory and the hazards associated with the work. Berkeley Lab`s set of Work Smart Standards includes required Federal, State and local laws and, additionally, national and international standards which represent the highest operating standards of industrial and commercial institutions.

  8. New wave generation

    E-Print Network [OSTI]

    Mercier, Matthieu J.

    We present the results of a combined experimental and numerical study of the generation of internal waves using the novel internal wave generator design of Gostiaux et al. (Exp. Fluids, vol. 42, 2007, pp. 123–130). This ...

  9. Hydrogen Generation From Electrolysis

    SciTech Connect (OSTI)

    Steven Cohen; Stephen Porter; Oscar Chow; David Henderson

    2009-03-06T23:59:59.000Z

    Small-scale (100-500 kg H2/day) electrolysis is an important step in increasing the use of hydrogen as fuel. Until there is a large population of hydrogen fueled vehicles, the smaller production systems will be the most cost-effective. Performing conceptual designs and analyses in this size range enables identification of issues and/or opportunities for improvement in approach on the path to 1500 kg H2/day and larger systems. The objectives of this program are to establish the possible pathways to cost effective larger Proton Exchange Membrane (PEM) water electrolysis systems and to identify areas where future research and development efforts have the opportunity for the greatest impact in terms of capital cost reduction and efficiency improvements. System design and analysis was conducted to determine the overall electrolysis system component architecture and develop a life cycle cost estimate. A design trade study identified subsystem components and configurations based on the trade-offs between system efficiency, cost and lifetime. Laboratory testing of components was conducted to optimize performance and decrease cost, and this data was used as input to modeling of system performance and cost. PEM electrolysis has historically been burdened by high capital costs and lower efficiency than required for large-scale hydrogen production. This was known going into the program and solutions to these issues were the focus of the work. The program provided insights to significant cost reduction and efficiency improvement opportunities for PEM electrolysis. The work performed revealed many improvement ideas that when utilized together can make significant progress towards the technical and cost targets of the DOE program. The cell stack capital cost requires reduction to approximately 25% of today’s technology. The pathway to achieve this is through part count reduction, use of thinner membranes, and catalyst loading reduction. Large-scale power supplies are available today that perform in a range of efficiencies, >95%, that are suitable for the overall operational goals. The balance of plant scales well both operationally and in terms of cost becoming a smaller portion of the overall cost equation as the systems get larger. Capital cost reduction of the cell stack power supplies is achievable by modifying the system configuration to have the cell stacks in electrical series driving up the DC bus voltage, thereby allowing the use of large-scale DC power supply technologies. The single power supply approach reduces cost. Elements of the cell stack cost reduction and efficiency improvement work performed in the early stage of the program is being continued in subsequent DOE sponsored programs and through internal investment by Proton. The results of the trade study of the 100 kg H2/day system have established a conceptual platform for design and development of a next generation electrolyzer for Proton. The advancements started by this program have the possibility of being realized in systems for the developing fueling markets in 2010 period.

  10. Energy Management Programs- Monitoring Performance

    E-Print Network [OSTI]

    Pauls, S. P.; Shamy, M. D.

    ENERGY MANAGEMENT PROGRAMS - MONITORING PERFORMANCE Stanley P. Pauls Mustafa D. Shamy Merck & Co., Inc. Rahway, N. J. ABSTRACT of the historical energy consumption records. Energy use standards have been established to Steam Model monitor... energy conservation performance in bulk pharmaceutical plants. The model considers The basic steam model for most industrial process, comfort heating, and fixed loads. operations is made up of the following components: As the oil crisis developed...

  11. Energy savings estimates and cost benefit calculations for high performance relocatable classrooms

    SciTech Connect (OSTI)

    Rainer, Leo I.; Hoeschele, Marc A.; Apte, Michael G.; Shendell, Derek G.; Fisk, Wlliam J.

    2003-12-01T23:59:59.000Z

    This report addresses the results of detailed monitoring completed under Program Element 6 of Lawrence Berkeley National Laboratory's High Performance Commercial Building Systems (HPCBS) PIER program. The purpose of the Energy Simulations and Projected State-Wide Energy Savings project is to develop reasonable energy performance and cost models for high performance relocatable classrooms (RCs) across California climates. A key objective of the energy monitoring was to validate DOE2 simulations for comparison to initial DOE2 performance projections. The validated DOE2 model was then used to develop statewide savings projections by modeling base case and high performance RC operation in the 16 California climate zones. The primary objective of this phase of work was to utilize detailed field monitoring data to modify DOE2 inputs and generate performance projections based on a validated simulation model. Additional objectives include the following: (1) Obtain comparative performance data on base case and high performance HVAC systems to determine how they are operated, how they perform, and how the occupants respond to the advanced systems. This was accomplished by installing both HVAC systems side-by-side (i.e., one per module of a standard two module, 24 ft by 40 ft RC) on the study RCs and switching HVAC operating modes on a weekly basis. (2) Develop projected statewide energy and demand impacts based on the validated DOE2 model. (3) Develop cost effectiveness projections for the high performance HVAC system in the 16 California climate zones.

  12. Standards and the design of the Advanced Photon Source control system

    SciTech Connect (OSTI)

    McDowell, W.P.; Knott, M.J.; Lenkszus, F.R.; Kraimer, M.R.; Daly, R.T.; Arnold, N.D.; Anderson, M.D.; Anderson, J.B.; Zieman, R.C.; Cha, Ben-Chin K.; Vong, F.C.; Nawrocki, G.J.; Gunderson, G.R.; Karonis, N.T.; Winans, J.R.

    1991-12-01T23:59:59.000Z

    The Advanced Photon Source (APS), now under construction at Argonne National Laboratory is a 7 GeV positron storage ring dedicated to research facilities using synchrotron radiation. This ring, along with its injection accelerators is to be controlled and monitored with a single, flexible, and expandable control system. In the conceptual stage the control system design group faced the challenges that face all control system designers: to force the machine designers to quantify and codify the system requirements, to protect the investment in hardware and software from rapid obsolescence, and to find methods of quickly incorporating new generations of equipment and replace of obsolete equipment without disrupting the exiting system. To solve these and related problems, the APS control system group made an early resolution to use standards in the design of the system. This paper will cover the present status of the APS control system as well as discuss the design decisions which led us to use industrial standards and collaborations with other laboratories whenever possible to develop a control system. It will explain the APS control system and illustrate how the use of standards has allowed APS to design a control system whose implementation addresses these issues. The system will use high performance graphic workstations using an X-Windows Graphical User Interface at the operator interface level. It connects to VME-based microprocessors at the field level using TCP/IP protocols over high performance networks. This strategy assures the flexibility and expansibility of the control system. A defined interface between the system components will allow the system to evolve with the direct addition of future, improved equipment and new capabilities.

  13. Volume 118 (2013) http://dx.doi.org/10.6028/jres.118.014 Journal of Research of the National Institute of Standards and Technology

    E-Print Network [OSTI]

    2013-01-01T23:59:59.000Z

    Engineers (ANSI/IEEE) and International Electrotechnical Commission (IEC) standards. Table 1 lists the relevant ANSI/IEEE and IEC standards which have been published or are currently under development of published ANSI/IEEE and IEC standards ANSI/IEEE standards IEC standards ANSI/IEEE N42.32 Performance

  14. Nuclear Data Verification and Standardization

    SciTech Connect (OSTI)

    Karam, Lisa R.; Arif, Muhammad; Thompson, Alan K.

    2011-10-01T23:59:59.000Z

    The objective of this interagency program is to provide accurate neutron interaction verification and standardization data for the U.S. Department of Energy Division of Nuclear Physics programs which include astrophysics, radioactive beam studies, and heavy-ion reactions. The measurements made in this program are also useful to other programs that indirectly use the unique properties of the neutron for diagnostic and analytical purposes. These include homeland security, personnel health and safety, nuclear waste disposal, treaty verification, national defense, and nuclear based energy production. The work includes the verification of reference standard cross sections and related neutron data employing the unique facilities and capabilities at NIST and other laboratories as required; leadership and participation in international intercomparisons and collaborations; and the preservation of standard reference deposits. An essential element of the program is critical evaluation of neutron interaction data standards including international coordinations. Data testing of critical data for important applications is included. The program is jointly supported by the Department of Energy and the National Institute of Standards and Technology.

  15. Measurement uncertainties for vacuum standards at Korea Research Institute of Standards and Science

    SciTech Connect (OSTI)

    Hong, S. S.; Shin, Y. H.; Chung, K. H. [Vacuum Center, Korea Research Institute of Standards and Science, Daejeon 305-600 (Korea, Republic of)

    2006-09-15T23:59:59.000Z

    The Korea Research Institute of Standards and Science has three major vacuum systems: an ultrasonic interferometer manometer (UIM) (Sec. II, Figs. 1 and 2) for low vacuum, a static expansion system (SES) (Sec. III, Figs. 3 and 4) for medium vacuum, and an orifice-type dynamic expansion system (DES) (Sec. IV, Figs. 5 and 6) for high and ultrahigh vacuum. For each system explicit measurement model equations with multiple variables are, respectively, given. According to ISO standards, all these system variable errors were used to calculate the expanded uncertainty (U). For each system the expanded uncertainties (k=1, confidence level=95%) and relative expanded uncertainty (expanded uncertainty/generated pressure) are summarized in Table IV and are estimated to be as follows. For UIM, at 2.5-300 Pa generated pressure, the expanded uncertainty is <4.17x10{sup -2} Pa and the relative expanded uncertainty is <1.18x10{sup -2}; at 1-100 kPa generated pressure, the expanded uncertainty is <7.87 Pa and the relative expanded uncertainty is <7.84x10{sup -5}. For SES, at 3-100 Pa generated pressure, the expanded uncertainty is <1.77x10{sup -1} Pa and the relative expanded uncertainty is <1.81x10{sup -3}. For DES, at 4.6x10{sup -3}-1.3x10{sup -2} Pa generated pressure, the expanded uncertainty is <1.04x10{sup -4} Pa and the relative expanded uncertainty is <8.37x10{sup -3}; at 3.0x10{sup -6}-9.0x10{sup -4} Pa generated pressure, the expanded uncertainty is <8.21x10{sup -6} Pa and the relative expanded uncertainty is <1.37x10{sup -2}. Within uncertainty limits our bilateral and key comparisons [CCM.P-K4 (10 Pa-1 kPa)] are extensive and in good agreement with those of other nations (Fig. 8 and Table V)

  16. MODEL-DRIVEN ENGINEERING FOR IMPLEMENTING THE ISO 19100 SERIES OF INTERNATIONAL STANDARDS

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    MODEL-DRIVEN ENGINEERING FOR IMPLEMENTING THE ISO 19100 SERIES OF INTERNATIONAL STANDARDS CYRIL of the ISO 19100 series of standards with use of Model-Driven Engineering (MDE) techniques. We expose how MDE to use ISO 19109, 19110 and 19117 models in order to generate a rich client application. Our work takes

  17. Defining a Standard Metric for Electricity Savings

    E-Print Network [OSTI]

    Koomey, Jonathan

    2009-01-01T23:59:59.000Z

    capacity for U.S. coal fired power generation is remarkablyfired capacity, net generation and coal consumed taken fromof their electricity generation comes from coal. LIMITATIONS

  18. Liquid soap film generates electricity

    E-Print Network [OSTI]

    Ahmad Amjadi; Sadegh Feiz; Reza Montazeri Namin

    2014-04-24T23:59:59.000Z

    We have observed that a rotating liquid soap film generates electricity when placed between two non-contact electrodes with a sufficiently large potential difference. In our experiments suspended liquid film (water + soap film) is formed on the surface of a circular frame, which is forced to rotate in the $x-y$ horizontal plane by a motor. This system is located at the center of two capacitor-like vertical plates to apply an external electric voltage difference in the $x-$direction. The produced electric current is collected from the liquid film using two conducting electrodes that are separated in the $y-$direction. We previously reported that a liquid film in an external electric field rotates when an electric current passes through it, naming it the liquid film motor (LFM). In this paper we report a novel technique, in which a similar device can be used as an electric generator, converting the rotating mechanical energy to electrical energy. The liquid film electric generator (LFEG) is in stark contrast to the LFM, both of which could be designed similarly in very small scales like micro scales with different applications. Although the device is comparable to commercial electric motors or electric generators, there is a significant difference in their working principles. Usually in an electric motor or generator the magnetic field causes the driving force, while in a LFM or LFEG the Coulomb force is the driving force. This fact is also interesting from the Bio-science point of view and brings a similarity to bio motors. Here we have investigated the electrical characteristics of such a generator for the first time experimentally and modelled the phenomenon with electroconvection governing equations. A numerical simulation is performed using the local approximation for the charge-potential relation and results are in qualitative agreement with experiments.

  19. High Performance Fortran Language Specification

    E-Print Network [OSTI]

    Shewchuk, Jonathan

    Version 1.1 #12; The High Performance Fortran Forum (HPFF), with participation from over 40 organ will become widely available, HPFF is not sanctioned or supported by any official standards organization. The HPFF had a second series of meetings from April 1994 to October 1994 to consider requests

  20. Performance indicators for 1st quarter CY 1993

    SciTech Connect (OSTI)

    Not Available

    1993-08-01T23:59:59.000Z

    The Department of Energy (DOE) has established a Department-wide Performance Indicator (PI) Program for trending and analysis of operational data as directed by DOE Order 5480.26. The PI Program was established to provide a means for monitoring the environment, safety, and health (ES&H) performance of the DOE at the Secretary and other management levels. This is the ninth in a series of quarterly reports generated for the Department of Energy Field Office, Idaho (DOE-ID) by EG&G Idaho, Inc. to meet the requirements of the PI Program as directed by the DOE Standard. DOE-STD-1048-92 identifies four general areas of PIs. They are: Personnel Safety, Operational Incidents, Environment and Management. These four areas have been subdivided into 26 performance indicators. Approximately 115 performance indicator control and distribution charts comprise the body of this report A brief summary of PIs contained in each of these general areas is provided in the following pages. The four EG&G facilities whose performance is charted herein are as follows: (1) The Advanced Test Reactor (ATR); (2) The Radioactive Waste Management Complex (RWMC); (3) The Waste Experimental Reduction Facility (WERF) and (4) The Test Reactor Area (TRA) Hot Cells.

  1. Motor/generator

    DOE Patents [OSTI]

    Hickam, Christopher Dale (Glasford, IL)

    2008-05-13T23:59:59.000Z

    A motor/generator is provided for connecting between a transmission input shaft and an output shaft of a prime mover. The motor/generator may include a motor/generator housing, a stator mounted to the motor/generator housing, a rotor mounted at least partially within the motor/generator housing and rotatable about a rotor rotation axis, and a transmission-shaft coupler drivingly coupled to the rotor. The transmission-shaft coupler may include a clamp, which may include a base attached to the rotor and a plurality of adjustable jaws.

  2. DTU Synthetic Promoter Library Standard

    E-Print Network [OSTI]

    Fortuna, Patrick

    2010-12-04T23:59:59.000Z

    The purpose of this RFC is to outline a method for generating a BioBrick compatible Synthetic Promoter Library (SPL) within bacteria in order to fine-tune the expression of BioBrick parts and devices.

  3. Performance comparison of alternative fuzzy control modalities

    E-Print Network [OSTI]

    House, Corey Dean

    1998-01-01T23:59:59.000Z

    Through the medium of computer simulation, this thesis documents thorough performance caparisons of several different fuzzy control schemes, using a standard problem in the literature, the inverted pendulum. In order to have a firm basis...

  4. Critical Performance and Durability Parameters of an Integrated...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and Durability Parameters of an Integrated Aftertreatment System used to Meet Tier II Emission Standards Critical Performance and Durability Parameters of an Integrated...

  5. The Adequacy of DOE Natural Phenomena Hazards Performance Goals...

    Office of Environmental Management (EM)

    Assess whether the DOE NPH performance goal concept as used in the Documented Safety Analysis process is adequate or needs additional guidance Background * ANS Standard...

  6. Comparative evaluation of cooling tower drift eliminator performance

    E-Print Network [OSTI]

    Chan, Joseph Kwok-Kwong

    The performance of standard industrial evaporative cooling tower drift eliminators is analyzed using experiments and numerical simulations. The experiments measure the

  7. Creating a Cognitive Agent in a Virtual World: Planning, Navigation, and Natural Language Generation

    E-Print Network [OSTI]

    Hewlett, William

    2013-01-01T23:59:59.000Z

    Generation . . . . . . . . . . . . . . . . . . . . .Language Generation . . . . . . . . . . . . . . . . .Language Generation . . . . . . . . . . . . . . . . . . . .

  8. Neutrino-Argon Interaction with GENIE Event Generator

    SciTech Connect (OSTI)

    Chesneanu, Daniela [Faculty of Physics, University of Bucharest, Bucharest (Romania); National Institute for Nuclear Physics and Engineering 'Horia Hulubei' Bucharest-Magurele (Romania)

    2010-11-24T23:59:59.000Z

    Neutrinos are very special particles, have only weak interactions, except gravity, and are produced in very different processes in Nuclear and Particle Physics. Neutrinos are, also, messengers from astrophysical objects, as well as relics from Early Universe. Therefore, its can give us information on processes happening in the Universe, during its evolution, which cannot be studied otherwise. The underground instrumentation including a variety of large and very large detectors, thanks to technical breakthroughs, have achieved new fundamental results like the solution of the solar neutrino puzzle and the evidence for Physics beyond the Standard Model of elementary interactions in the neutrino sector with non-vanishing neutrino masses and lepton flavour violation.Two of the LAGUNA(Large Apparatus studying Grand Unification and Neutrino Astrophysics) detectors, namely: GLACIER (Giant Liquid Argon Charge Imaging ExpeRiment) and LENA (Low Energy Neutrino Astrophysics) could be emplaced in 'Unirea' salt mine from Slanic-Prahova, Romania. A detailed analysis of the conditions and advantages is necessary. A few results have been presented previously. In the present work, we propose to generate events and compute the cross sections for interactions between neutrino and Argon-40, to estimate possible detection performances and event types. For doing this, we use the code GENIE(G lowbar enerates E lowbar vents for N lowbar eutrino I lowbar nteraction E lowbar xperiments). GENIE Code is an Object-Oriented Neutrino MC Generator supported and developed by an international collaboration of neutrino interaction experts.

  9. A Nonempirical Test on the Weight of Pseudorandom Number Generators

    E-Print Network [OSTI]

    Matsumoto, Makoto

    A Nonempirical Test on the Weight of Pseudorandom Number Generators Makoto Matsumoto1 and Takuji introduce a theoretical test, named weight discrepancy test, on pseu- dorandom number generators. This test selected. This test can be performed for most generators based on a linear recursion over the two

  10. TOWARDS REAL-TIME GENERATION SCHEDULING IN MICROGRIDS WITH

    E-Print Network [OSTI]

    Zhang, Junshan

    TOWARDS REAL-TIME GENERATION SCHEDULING IN MICROGRIDS WITH PERFORMANCE GUARANTEE LIAN LU, JINLONG TU, CHI-KIN CHAU, MINGHUA CHEN, ZHAO XU AND XIAOJUN LIN INTRODUCTION Microgrid is an emerging- generation improves generation efficiency by 2-3x. A key problem in microgrid operations is how to schedule

  11. NREL Enables Efficient Data Exchange for Home Performance Companies (Fact Sheet), NREL Highlights in Research & Development

    SciTech Connect (OSTI)

    Merket, N.

    2014-01-01T23:59:59.000Z

    NREL supports standard data transfer protocol to streamline communication of home performance tracking systems and upgrade analysis software.

  12. RENEWABLES PORTFOLIO STANDARD 2006 PROCUREMENT VERIFICATION

    E-Print Network [OSTI]

    .............................................................................................. 10 Flexible Compliance .................................................................................................... 14 Sources of Generation Data

  13. RENEWABLES PORTFOLIO STANDARD 2006 PROCUREMENT VERIFICATION

    E-Print Network [OSTI]

    ................................................................................................ 5 Flexible Compliance .................................................................................................... 10 Sources of Generation Data .....................................................................................

  14. An overview of software safety standards

    SciTech Connect (OSTI)

    Lawrence, J.D.

    1995-10-01T23:59:59.000Z

    The writing of standards for software safety is an increasingly important activity. This essay briefly describes the two primary standards-writing organizations, IEEE and IEC, and provides a discussion of some of the more interesting software safety standards.

  15. Information Technology: American National Standard for Information

    E-Print Network [OSTI]

    Information Technology: American National Standard for Information Systems-- Data Format-271 Information Technology: American National Standard for Information Systems-- Data Format for the Interchange Sponsored by Information Access Division Information Technology Laboratory National Institute of Standards

  16. Version Auteur Monitoring the International Standardization Process

    E-Print Network [OSTI]

    Boyer, Edmond

    organizations are in charge of global security management. To address this issue, ISO (International Standards Organization), the main international organization for technical standardization, has launched a set of studiesVersion Auteur Monitoring the International Standardization Process Theoretical Choices

  17. Standard review plan for dry cask storage systems. Final report

    SciTech Connect (OSTI)

    NONE

    1997-01-01T23:59:59.000Z

    The Standard Review Plan (SRP) For Dry Cask Storage Systems provides guidance to the Nuclear Regulatory Commission staff in the Spent Fuel Project Office for performing safety reviews of dry cask storage systems. The SRP is intended to ensure the quality and uniformity of the staff reviews, present a basis for the review scope, and clarification of the regulatory requirements. Part 72, Subpart B generally specifies the information needed in a license application for the independent storage of spent nuclear fuel and high level radioactive waste. Regulatory Guide 3.61 {open_quotes}Standard Format and Content for a Topical Safety Analysis Report for a Spent Fuel Dry Storage Cask{close_quotes} contains an outline of the specific information required by the staff. The SRP is divided into 14 sections which reflect the standard application format. Regulatory requirements, staff positions, industry codes and standards, acceptance criteria, and other information are discussed.

  18. Standard Two: Planning and Evaluation

    E-Print Network [OSTI]

    Snider, Barry B.

    13 Standard Two: Planning and Evaluation Overview Brandeis University's goals are to sustain committed to reflection, analysis, and evaluation, Brandeis has engaged over the past decade and a half Thier's 1992 Reestablishing Academic and Economic Equilibrium, and President Reinharz's 1996 Brandeis

  19. Residential ventilation standards scoping study

    SciTech Connect (OSTI)

    McKone, Thomas E.; Sherman, Max H.

    2003-10-01T23:59:59.000Z

    The goals of this scoping study are to identify research needed to develop improved ventilation standards for California's Title 24 Building Energy Efficiency Standards. The 2008 Title 24 Standards are the primary target for the outcome of this research, but this scoping study is not limited to that timeframe. We prepared this scoping study to provide the California Energy Commission with broad and flexible options for developing a research plan to advance the standards. This document presents the findings of a scoping study commissioned by the Public Interest Energy Research (PIER) program of the California Energy Commission to determine what research is necessary to develop new residential ventilation requirements for California. This study is one of three companion efforts needed to complete the job of determining the ventilation needs of California residences, determining the bases for setting residential ventilation requirements, and determining appropriate ventilation technologies to meet these needs and requirements in an energy efficient manner. Rather than providing research results, this scoping study identifies important research questions along with the level of effort necessary to address these questions and the costs, risks, and benefits of pursuing alternative research questions. In approaching these questions and corresponding levels of effort, feasibility and timing were important considerations. The Commission has specified Summer 2005 as the latest date for completing this research in time to update the 2008 version of California's Energy Code (Title 24).

  20. Standards for language encoding: ISO

    E-Print Network [OSTI]

    Erjavec, Toma?

    Standards for language encoding: ISO Tomaz Erjavec Dept. of Knowledge Technologies Jozef Stefan Institute ESSLLI 2011 #12;Overview of the lecture 1. How ISO works 2. ISO TC 37 3. Dates, times & languages 4. ISO Annotation Frameworks #12;http://www.iso.org/ The world's largest developer and publisher

  1. Tools for event generator tuning and validation

    E-Print Network [OSTI]

    Andy Buckley

    2008-09-26T23:59:59.000Z

    I describe the current status of MCnet tools for validating the performance of event generator simulations against data, and for tuning their phenomenological free parameters. For validation, the Rivet toolkit is now a mature and complete system, with a large library of prominent benchmark analyses. For tuning, the Professor system has recently completed its first tunes of Pythia 6, with substantial improvements on the existing default tune and potential to greatly aid the setup of new generators for LHC studies.

  2. National Certification Standard for Ground Source Heat Pump Personnel

    SciTech Connect (OSTI)

    Kelly, John [Geothermal Heat Pump Consortium] [Geothermal Heat Pump Consortium

    2013-07-31T23:59:59.000Z

    The National Certification Standard for the Geothermal Heat Pump Industry adds to the understanding of the barriers to rapid growth of the geothermal heat pump (GHP) industry by bringing together for the first time an analysis of the roles and responsibilities of each of the individual job tasks involved in the design and installation of GHP systems. The standard addresses applicable qualifications for all primary personnel involved in the design, installation, commissioning, operation and maintenance of GHP systems, including their knowledge, skills and abilities. The resulting standard serves as a foundation for subsequent development of curriculum, training and certification programs, which are not included in the scope of this project, but are briefly addressed in the standard to describe ways in which the standard developed in this project may form a foundation to support further progress in accomplishing those other efforts. Follow-on efforts may use the standard developed in this project to improve the technical effectiveness and economic feasibility of curriculum development and training programs for GHP industry personnel, by providing a more complete and objective assessment of the individual job tasks necessary for successful implementation of GHP systems. When incorporated into future certification programs for GHP personnel, the standard will facilitate increased consumer confidence in GHP technology, reduce the potential for improperly installed GHP systems, and assure GHP system quality and performance, all of which benefit the public through improved energy efficiency and mitigated environmental impacts of the heating and cooling of homes and businesses.

  3. Standard test methods for Rockwell hardness of metallic materials

    E-Print Network [OSTI]

    American Society for Testing and Materials. Philadelphia

    2008-01-01T23:59:59.000Z

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines\tAnnex A1 Rockwell Hardness Standardizing Machines\tAnnex A2 Standardization of Rockwell Indenters\tAnnex A3 Standardization of Rockwell Hardness Test Blocks\tAnnex A4 Guidelines for Determining the Minimum Thickness of a Test Piece\tAnnex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces\tAnnex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength\tAppendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty\tAppendi...

  4. The ALEPH Search for the Standard Model Higgs Boson

    E-Print Network [OSTI]

    J. A. Kennedy

    2001-11-01T23:59:59.000Z

    A search has been performed for the Standard Model Higgs boson in the data collected with the ALEPH detector in 2000. An excess of 3 sigma above the background expectation is found. The observed excess is consistent with the production of the Higgs boson with a mass close to 114 GeV/c2.

  5. NEXT GENERATION TURBINE PROGRAM

    SciTech Connect (OSTI)

    William H. Day

    2002-05-03T23:59:59.000Z

    The Next Generation Turbine (NGT) Program's technological development focused on a study of the feasibility of turbine systems greater than 30 MW that offer improvement over the 1999 state-of-the-art systems. This program targeted goals of 50 percent turndown ratios, 15 percent reduction in generation cost/kW hour, improved service life, reduced emissions, 400 starts/year with 10 minutes to full load, and multiple fuel usage. Improvement in reliability, availability, and maintainability (RAM), while reducing operations, maintenance, and capital costs by 15 percent, was pursued. This program builds on the extensive low emissions stationary gas turbine work being carried out by Pratt & Whitney (P&W) for P&W Power Systems (PWPS), which is a company under the auspices of the United Technologies Corporation (UTC). This study was part of the overall Department of Energy (DOE) NGT Program that extends out to the year 2008. A follow-on plan for further full-scale component hardware testing is conceptualized for years 2002 through 2008 to insure a smooth and efficient transition to the marketplace for advanced turbine design and cycle technology. This program teamed the National Energy Technology Laboratory (NETL), P&W, United Technologies Research Center (UTRC), kraftWork Systems Inc., a subcontractor on-site at UTRC, and Multiphase Power and Processing Technologies (MPPT), an off-site subcontractor. Under the auspices of the NGT Program, a series of analyses were performed to identify the NGT engine system's ability to serve multiple uses. The majority were in conjunction with a coal-fired plant, or used coal as the system fuel. Identified also was the ability of the NGT system to serve as the basis of an advanced performance cycle: the humid air turbine (HAT) cycle. The HAT cycle is also used with coal gasification in an integrated cycle HAT (IGHAT). The NGT systems identified were: (1) Feedwater heating retrofit to an existing coal-fired steam plant, which could supply both heat and peaking power (Block 2 engine); (2) Repowering of an older coal-fired plant (Block 2 engine); (3) Gas-fired HAT cycle (Block 1 and 2 engines); (4) Integrated gasification HAT (Block 1 and 2 engines). Also under Phase I of the NGT Program, a conceptual design of the combustion system has been completed. An integrated approach to cycle optimization for improved combustor turndown capability has been employed. The configuration selected has the potential for achieving single digit NO{sub x}/CO emissions between 40 percent and 100 percent load conditions. A technology maturation plan for the combustion system has been proposed. Also, as a result of Phase I, ceramic vane technology will be incorporated into NGT designs and will require less cooling flow than conventional metallic vanes, thereby improving engine efficiency. A common 50 Hz and 60 Hz power turbine was selected due to the cost savings from eliminating a gearbox. A list of ceramic vane technologies has been identified for which the funding comes from DOE, NASA, the U.S. Air Force, and P&W.

  6. Elemental Analyses of Hanford Surface Neutron Moisture Measurement Calibration Standard Samples

    SciTech Connect (OSTI)

    Watson, W.T., Westinghouse Hanford

    1996-07-31T23:59:59.000Z

    Elemental analyses have been performed on twenty samples taken from the moisture standards prepared to use in performing experimental calibrations of the surface neutron moisture measurement system. These standards consisted of mixtures of sand, hydrated alumina, and boron carbide. Elemental analyses were performed primarily to discover the quantities of any strong thermal neutron absorbers that may have been present in the mixture in unknown trace quantities.

  7. Method of grid generation

    DOE Patents [OSTI]

    Barnette, Daniel W. (Veguita, NM)

    2002-01-01T23:59:59.000Z

    The present invention provides a method of grid generation that uses the geometry of the problem space and the governing relations to generate a grid. The method can generate a grid with minimized discretization errors, and with minimal user interaction. The method of the present invention comprises assigning grid cell locations so that, when the governing relations are discretized using the grid, at least some of the discretization errors are substantially zero. Conventional grid generation is driven by the problem space geometry; grid generation according to the present invention is driven by problem space geometry and by governing relations. The present invention accordingly can provide two significant benefits: more efficient and accurate modeling since discretization errors are minimized, and reduced cost grid generation since less human interaction is required.

  8. Steam generator support system

    DOE Patents [OSTI]

    Moldenhauer, J.E.

    1987-08-25T23:59:59.000Z

    A support system for connection to an outer surface of a J-shaped steam generator for use with a nuclear reactor or other liquid metal cooled power source is disclosed. The J-shaped steam generator is mounted with the bent portion at the bottom. An arrangement of elongated rod members provides both horizontal and vertical support for the steam generator. The rod members are interconnected to the steam generator assembly and a support structure in a manner which provides for thermal distortion of the steam generator without the transfer of bending moments to the support structure and in a like manner substantially minimizes forces being transferred between the support structure and the steam generator as a result of seismic disturbances. 4 figs.

  9. Steam generator support system

    DOE Patents [OSTI]

    Moldenhauer, James E. (Simi Valley, CA)

    1987-01-01T23:59:59.000Z

    A support system for connection to an outer surface of a J-shaped steam generator for use with a nuclear reactor or other liquid metal cooled power source. The J-shaped steam generator is mounted with the bent portion at the bottom. An arrangement of elongated rod members provides both horizontal and vertical support for the steam generator. The rod members are interconnected to the steam generator assembly and a support structure in a manner which provides for thermal distortion of the steam generator without the transfer of bending moments to the support structure and in a like manner substantially minimizes forces being transferred between the support structure and the steam generator as a result of seismic disturbances.

  10. Estimating Wet Bulb Globe Temperature Using Standard Meteorological Measurements

    SciTech Connect (OSTI)

    Hunter, C.H.

    1999-11-18T23:59:59.000Z

    The heat stress management program at the Department of Energy''s Savannah River Site (SRS) requires implementation of protective controls on outdoor work based on observed values of wet bulb globe temperature (WBGT). To ensure continued compliance with heat stress program requirements, a computer algorithm was developed which calculates an estimate of WBGT using standard meteorological measurements. In addition, scripts were developed to generate a calculation every 15 minutes and post the results to an Intranet web site.

  11. Enforcement Policy Statement: Regional Standards Enforcement...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    42 U.S.C. 6291-6309, which set forth amended energy conservation standards for central air conditioners and heat pumps, including regional standards in certain States....

  12. Appliance and Equipment Energy Efficiency Standards

    Broader source: Energy.gov [DOE]

    '' Note: The federal government has imposed and updated appliance efficiency standards through several legislative acts,* and now has standards in place or under development for 30 classes of...

  13. Alternative Energy Portfolio Standard | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Portfolio Standard Provider Pennsylvania Public Utility Commission Pennsylvania's Alternative Energy Portfolio Standard (AEPS), created by S.B. 1030 on November 30, 2004,...

  14. Quality Assurance Functional Area Qualification Standard - DOE...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    50-2013, Quality Assurance Functional Area Qualification Standard by Administrator The Quality Assurance (QA) Functional Area Qualification Standard (FAQS) establishes common...

  15. Ambient Air Quality Standards (New Jersey)

    Broader source: Energy.gov [DOE]

    This article lists specific standards for ambient air quality standards for particulate matter, sulfur dioxide, carbon monoxide, ozone, lead and nitrogen dioxide.

  16. Technical Standards, Program Project Justification Statement...

    Energy Savers [EERE]

    Standards, Program Project Justification Statement - August 29, 2012 August 29, 2012 DOE Technical Standards Program Project Justification Statement As part of the new...

  17. Social Responsibility Standards: A Quick Glimpse Although efforts to establish measurements, standards and certifications related to

    E-Print Network [OSTI]

    Aalberts, Daniel P.

    : ISO Standard 24000--Social Responsibility: The International Organization current apply FSC standards for forest management. International Organic for Standardization is developing an international standard of voluntary guidelines for social

  18. Optimal_Performance_of_Hybrid_Generation_2011-05-24

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... 26 Exhibit 10 Real-Time Locational Marginal Price (PJM 912009 - 972009) ... 27 Exhibit 11 Wind Power (PJM...

  19. Improving Dynamic Load and Generator Response Performance Tools

    E-Print Network [OSTI]

    Lesieutre, Bernard C.

    2005-01-01T23:59:59.000Z

    in dynamic simulations of power systems. Using the PCMDynamic Simulations: The Probabilistic Collocation Method,” IEEE Transactions on Power Systems,Dynamic Simulations with Improved Representation of Loads and their Connection to a Power System,”

  20. High Performance, Low Cost Hydrogen Generation from Renewable Energy

    Broader source: Energy.gov [DOE]

    2011 DOE Hydrogen and Fuel Cells Program, and Vehicle Technologies Program Annual Merit Review and Peer Evaluation