Powered by Deep Web Technologies
Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Natural Gas Pipe Line Companies (Connecticut) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pipe Line Companies (Connecticut) Pipe Line Companies (Connecticut) Natural Gas Pipe Line Companies (Connecticut) < Back Eligibility Agricultural Commercial Construction Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Program Info State Connecticut Program Type Siting and Permitting Provider Public Utilities Regulatory Authority These regulations list standards and considerations for the design, construction, compression, metering, operation, and maintenance of natural gas pipelines, along with procedures for records, complaints, and service

2

ACOUSTIC DETECTING AND LOCATING GAS PIPE LINE INFRINGEMENT  

Science Conference Proceedings (OSTI)

The extensive network of high-pressure natural gas transmission pipelines covering the United States provides an important infrastructure for our energy independence. Early detection of pipeline leaks and infringements by construction equipment, resulting in corrosion fractures, presents an important aspect of our national security policy. The National Energy Technology Laboratory Strategic Center for Natural Gas (SCVG) is and has been funding research on various applicable techniques. The WVU research team has focused on monitoring pipeline background acoustic signals generated and transmitted by gas flowing through the gas inside the pipeline. In case of a pipeline infringement, any mechanical impact on the pipe wall, or escape of high-pressure gas, generates acoustic signals traveling both up and down stream through the gas. Sudden changes in flow noise are detectable with a Portable Acoustic Monitoring Package (PAMP), developed under this contract. It incorporates a pressure compensating microphone and a signal- recording device. Direct access to the gas inside the line is obtained by mounting such a PAMP, with a 1/2 inch NPT connection, to a pipeline pressure port found near most shut-off valves. An FFT of the recorded signal subtracted by that of the background noise recorded one-second earlier appears to sufficiently isolate the infringement signal to allow source interpretation. Using cell phones for data downloading might allow a network of such 1000-psi rated PAMP's to acoustically monitor a pipeline system and be trained by neural network software to positively identify and locate any pipeline infringement.

John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Patrick Browning

2004-12-01T23:59:59.000Z

3

ACOUSTIC DETECTING AND LOCATING GAS PIPE LINE INFRINGEMENT  

Science Conference Proceedings (OSTI)

The extensive network of high-pressure natural gas transmission pipelines covering the United States provides an important infrastructure for our energy independence. Early detection of pipeline leaks and infringements by construction equipment, resulting in corrosion fractures, presents an important aspect of our national security policy. The National Energy Technology Laboratory Strategic Center for Natural Gas (SCVG) is and has been funding research on various applicable techniques. The WVU research team has focused on monitoring pipeline background acoustic signals generated and transmitted by gas flowing through the gas inside the pipeline. In case of a pipeline infringement, any mechanical impact on the pipe wall, or escape of high-pressure gas, generates acoustic signals traveling both up and down stream through the gas. Sudden changes in flow noise are detectable with a Portable Acoustic Monitoring Package (PAMP), developed under this contract. It incorporates a pressure compensating microphone and a signal- recording device. Direct access to the gas inside the line is obtained by mounting such a PAMP, with a 1/2 inch NPT connection, to a pipeline pressure port found near most shut-off valves. An FFT of the recorded signal subtracted by that of the background noise recorded one-second earlier appears to sufficiently isolate the infringement signal to allow source interpretation. Using cell phones for data downloading might allow a network of such 1000-psi rated PAMP's to acoustically monitor a pipeline system and be trained by neural network software to positively identify and locate any pipeline infringement.

John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Patrick Browning

2004-10-31T23:59:59.000Z

4

SULFUR REMOVAL FROM PIPE LINE NATURAL GAS FUEL: APPLICATION TO FUEL CELL POWER GENERATION SYSTEMS  

DOE Green Energy (OSTI)

Pipeline natural gas is being considered as the fuel of choice for utilization in fuel cell-based distributed generation systems because of its abundant supply and the existing supply infrastructure (1). For effective utilization in fuel cells, pipeline gas requires efficient removal of sulfur impurities (naturally occurring sulfur compounds or sulfur bearing odorants) to prevent the electrical performance degradation of the fuel cell system. Sulfur odorants such as thiols and sulfides are added to pipeline natural gas and to LPG to ensure safe handling during transportation and utilization. The odorants allow the detection of minute gas line leaks, thereby minimizing the potential for explosions or fires.

King, David L.; Birnbaum, Jerome C.; Singh, Prabhakar

2003-11-21T23:59:59.000Z

5

Steel Plate Processing for Line Pipes in Oil and Gas Transport  

Science Conference Proceedings (OSTI)

This has further helped in reducing the specific steel consumption in oil and gas transportation. The current focus on less wall thickness at increased strength ...

6

Internal cathodic protection of cement-lined steel pipes  

SciTech Connect

Internally coated, cement-lined, carbon steel pipes have been used extensively for ballast- and service-water systems offshore. Mechanical cracking of the lining, undercutting, and erosion have resulted in corrosion and system leaks. Cathodic protection is one alternative that has been evaluated as a solution. Cathodic protection normally gives limited protection when applied internally to a pipeline system. Tests have been performed to evaluate this hypothesis and the possibility of improved current distribution due to the cement lining. This paper presents the test results as well as a solution to the problem. Internally coated, cement-lined steel pipes are used for ballast-water, service-water, and fire-water systems in the offshore oil and gas production industry.

Jensen, F.O. (Sharpnord Corrosion, P.O. Box 46, 3971 Langesund (NO)); Tems, R.D. (Mobil Exploration Norway, Inc., P.O. Box 510, 4001 Stavanger (NO))

1988-07-01T23:59:59.000Z

7

Mexico/Central America; Trans-Mexico gas line studied  

Science Conference Proceedings (OSTI)

This paper reports that current and future pipe line activity in Mexico and Central America is at a low level, with Pemex constructing a small amount of gas transmission and liquids lines. However, plans for a trans-Mexico gas transmission line for imports and exports advance.

Not Available

1991-11-01T23:59:59.000Z

8

NREL: News Feature - Recycled Natural Gas Pipes Shore Up Green Building  

NLE Websites -- All DOE Office Websites (Extended Search)

Recycled Natural Gas Pipes Shore Up Green Building Recycled Natural Gas Pipes Shore Up Green Building July 17, 2009 Photo of a line of four large metal tubes coming out of the ground in a construction site with blue sky, hills and buildings in the background. Early photos show the first few reclaimed gas pipes being erected at the RSF construction site. Using these recycled pipes will be help the building attain LEED platinum status. Credit: Carl Cox Building a support structure of something, tried, true and tested like "off the shelf" steel is standard practice in building construction. NREL's effort to create the most energy efficient and "green" office building is putting a twist on an old standard. The columns that will carry the weight of floors and walls in the new Research Support Facilities (RSF) are

9

Heating and cooling the Raft River geothermal transite pipe line  

SciTech Connect

A preliminary transient heat transfer analysis to aid in defining operating limits for the 4000-foot-long transite pipe line at the Raft River geothermal test site was completed. The heat transfer problem was to determine the time required to cool down the line from a 285/sup 0/F operating temperature to 50/sup 0/F and the time to heat up the line from 50/sup 0/F to 285/sup 0/F such that the temperature differential across the pipe wall will not exceed 25/sup 0/F. The pipe and the surrounding soil was modeled with a two-dimensional heat transfer computer code assuming constant convective heat transfer at the soil-atmosphere interface. The results are sensitive to the soil thermal conductivity used in the calculation and imply that measurement of soil thermal conductivity used in the calculation and imply that measurement of soil thermal properties should be made in order to refine the calculations. Also, the effect of variable convective heat transfer at the soil surface should be investigated. However, the results reported here indicate the order of magnitude to be expected for cool-down and heat-up times when operating the transite pipe at the stated condition.

Shaffer, C.J.

1977-06-01T23:59:59.000Z

10

Cryogenic & Gas System Piping Pressure Tests (A Collection of PT Permits)  

Science Conference Proceedings (OSTI)

This engineering note is a collection of pipe pressure testing documents for various sections of piping for the D-Zero cryogenic and gas systems. High pressure piping must conform with FESHM chapter 5031.1. Piping lines with ratings greater than 150 psig have a pressure test done before the line is put into service. These tests require the use of pressure testing permits. It is my intent that all pressure piping over which my group has responsibility conforms to the chapter. This includes the liquid argon and liquid helium and liquid nitrogen cryogenic systems. It also includes the high pressure air system, and the high pressure gas piping of the WAMUS and MDT gas systems. This is not an all inclusive compilation of test documentation. Some piping tests have their own engineering note. Other piping section test permits are included in separate safety review documents. So if it isn't here, that doesn't mean that it wasn't tested. D-Zero has a back up air supply system to add reliability to air compressor systems. The system includes high pressure piping which requires a review per FESHM 5031.1. The core system consists of a pressurized tube trailer, supply piping into the building and a pressure reducing regulator tied into the air compressor system discharge piping. Air flows from the trailer if the air compressor discharge pressure drops below the regulator setting. The tube trailer is periodically pumped back up to approximately 2000 psig. A high pressure compressor housed in one of the exterior buildings is used for that purpose. The system was previously documented, tested and reviewed for Run I, except for the recent addition of piping to and from the high pressure compressor. The following documents are provided for review of the system: (1) Instrument air flow schematic, drg. 3740.000-ME-273995 rev. H; (2) Component list for air system; (3) Pressure testing permit for high pressure piping; (4) Documentation from Run I contained in D-Zero Engineering note 3740.214-EN-268, John Urbin 11120/90; (5) Pressure test procedure; (6) Schematic for pressure test; and (7) List of component pressure ratings. The goal of this independent review is to: (1) Reviewer makes recommendation to the Division/Section Safety Officer to approve the testing permit; and (2) Reviewer is satisfied the FESHM 5031 is met, and recommends to the division head that approval to operate be granted.

Rucinski, Russell A.; /Fermilab

2002-08-22T23:59:59.000Z

11

Characterization of Pipes, Drain Lines, and Ducts using the Pipe Explorer System  

Office of Scientific and Technical Information (OSTI)

MC/30172-97/C0803 MC/30172-97/C0803 Title: Characterization of Pipes, Drain Lines, and Ducts Using the Pipe Explorer System TM Authors: C.D. Cremer D.T. Kendrick E. Cramer Contractor: Science and Engineering Associates, Inc. 6100 Uptown Blvd, NE Albuquerque, NM 87100 Contract Number: DE-AC21-93MC30172 Conference: Industry Partnerships to Deploy Environmental Technology Conference Location: Morgantown, West Virginia Conference Dates: October 22-24, 1996 Conference Sponsor: Morgantown Energy Technology Center Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any

12

The Effect of Low Plasticity Burnishing on X65 Line Pipe Girth Welds ...  

Science Conference Proceedings (OSTI)

Presentation Title, The Effect of Low Plasticity Burnishing on X65 Line Pipe Girth Welds and Heat Affected Zones. Author(s), Peter Moore, Jeremy Scheel, Doug ...

13

Gas release driven dynamics in research reactors piping  

SciTech Connect

Analysis of the physical and chemical processes of radiolysis gas production, air absorption, diffusion controlled gas release and transport in the coolant cleaning system of the research reactor FRM II, which is now being in routine power operation in Munich, Germany, lead to the following conclusions: 1) The steady state pressure distribution in the siphon pipe allows that the horizontal part of the siphon pipe is filled with air. The air is isolated by about 1 m water column from the main pipe of the coolant cleaning system (CCS). This is a stable steady state. It has two positive impacts on the normal operation of the CCS: (a) there is effectively no bypass flow; (b) The air can not be transported through the pipe and therefore no deterioration of the pump performance is expected from the function of the siphon pipe. 2) Radiolysis gas production for coolant, that initially does not contain dissolved air, does not lead to any problem for the system. The gases are dissolved in the coolant at 2.2 bar and are not released for pressures reduction to about 1 bar, which is the minimum pressure in the CCS. 3) Assuming hypothetically a radiolysis gas production for coolant, which initially does contain dissolved air close to its saturation, leads to gas slug formation and its transport up to the pump. This could reduce the pump head and could lead to distortion of the normal operation. Systematic measurement of the hydrogen in the primary system at 100% power indicated, that this state is not realized in the system. The observed H{sub 2} concentration was between 0.016 e-6 and 0.380 e-6 which is of no concern at all. (authors)

Kolev, Nikolay Ivanov; Roloff-Bock, Iris; Schlicht, Gerhard [Framatome ANP, P.O. Box 3220, D-91058, Erlangen (Germany)

2006-07-01T23:59:59.000Z

14

Random Analysis on Line-Heat Source Temperature Field of Ground Source Heat Pumps Buried Pipes  

Science Conference Proceedings (OSTI)

In this paper the random properties of ground-source heat pump (GSHP) system.GSHP buried pipe to Kelvin one-dimensional line source of heat transfer model are discussed. The model randomness is analyzed, and the GSHP buried pipe to random excess temperature ... Keywords: GSHP, Buriedpipe, Line-heat source, Temperature field, Correlation

Changsheng Guan; Zhuodong Liu; Kai Xia; Xuyi Chen

2009-05-01T23:59:59.000Z

15

Marine surveys aid gas line  

Science Conference Proceedings (OSTI)

Detailed marine surveys helped B.C. Hydro, a Canadian gas distribution utility, select the submarine route portion of the proposed Vancouver Island gas pipeline system. In 1984, after a series of government hearings, B.C. Hydro's route selection was adopted by the British Columbia Provincial Government. Vancouver Island is the last major population center in Western Canada not supplied with natural gas. In fact, studies of a gas pipeline to the island have been carried out periodically over the past 30 years. But until recently, all schemes have appeared unattractive because of a combination of technical, economic, and political factors. The proposed Vancouver Island project which is awaiting funding, consists of a dual 52.7-km marine transmission pipeline link from the mainland to the island. Diameter of this portion of line will be either 12 of 16-in. Also, part of the proposed system will be an 18.5-km line on the mainland, a 280-km transmission pipeline on the island, compression facilities, and distribution systems in the major population centers. Diameters for the land portions will vary between 6 and 24 in. For several months in late 1983 and early 1984, the project was the subject of public hearings held by the British Columbia Utilities Commission. This process was complicated when two companies applied to construct and operate the marine pipeline link to the island using completely different routes and techniques. In July 1984, the commission recommended to the Provincial Government that B.C. Hydro's proposal for the marine pipeline be accepted. It further recommended that an Energy Project Certificate for construction of the pipeline link to the island be awarded to B.C. Hydro. The recommendation was accepted by the Provincial Government and the project now awaits a funding agreement between the Federal and Provincial Governments.

Park, C.A.; Baines, F.A. Koenig, H.L.

1986-05-05T23:59:59.000Z

16

A Gas-Fired Heat Pipe Zone Heater  

E-Print Network (OSTI)

A gas-fired vented zone heater has recently been developed by the Altar Corporation for Colorado State University (CSU) under a Gas Research Institute (GRI) contract. The unit war developed for auxiliary heating applications in passive solar buildings. An early prototype was tested at Altas and operated as expected. The final model was shipped to CSU in December 1983 for testing in the REPEAT Facility at CSU. A heat pipe extends through the wall to the outside of the building. It has a modest water charge which can freeze repeatedly with no damage, since the heat pips is only partially filled. Firing efficiency at 4,000 Btu/b (1.17 kW thermal) is approximately 80%. The unit features a 3 foot by 3 foot radiator mounted inside the room to be heated, and is thermostatically controlled. Ignition is accomplished with an electronic sparker (pilot). The radiator typically operates at 150-180°F (65-82°C), and has been operated at between 2,000 and 5,000 Btu/h (0.6-1.47 kW). Results of testing the vented heat pipe zone heater at CSU arm presented. Also, a method for determining the optimal combination of zone heater, passive solar heating and energy conservation measures has been developed. Nomographs have been developed that may be used by a building designer to determine the optimal combination of zone heater size, passive solar system size, and energy conservation measures for given types of passive solar heating systems in selected locations. A representative nomograph is presented along with a design example.

Winn, C. B.; Burns, P.; Guire, J.

1984-01-01T23:59:59.000Z

17

On-line ultrasonic gas entrainment monitor  

DOE Patents (OSTI)

Apparatus employing ultrasonic energy for detecting and measuring the quantity of gas bubbles present in liquids being transported through pipes. An ultrasonic transducer is positioned along the longitudinal axis of a fluid duct, oriented to transmit acoustic energy radially of the duct around the circumference of the enclosure walls. The back-reflected energy is received centrally of the duct and interpreted as a measure of gas entrainment. One specific embodiment employs a conical reflector to direct the transmitted acoustic energy radially of the duct and redirect the reflected energy back to the transducer for reception. A modified embodiment employs a cylindrical ultrasonic transducer for this purpose.

Day, Clifford K. (Richland, WA); Pedersen, Herbert N. (Richland, WA)

1978-01-01T23:59:59.000Z

18

Natural Gas Weekly Update, Printer-Friendly Version  

Annual Energy Outlook 2012 (EIA)

load in the region, various natural gas transportation providers such as Iroquois Gas Transmission Company, Tennessee Gas Pipeline, and Transcontinental Gas Pipe Line...

19

Design and fabrication of polymer-concrete-lined pipe for testing in geothermal-energy processes. Final report  

DOE Green Energy (OSTI)

A specific polymer-concrete formulation was applied as a steel pipe liner in response to a need for durable, economical materials for use in contact with high temperature geothermal brine. Processes are described for centrifugally applying the liner to straight pipe, for casting the liner in pipe fittings, and for closure of field joints. Physical properties of the liner materials were measured. Compressive strengths of up to 165.8 MPa (24,045 psi) and splitting tensile strengths of 23.5 MPa (3408 psi) were measured at ambient temperature. Compressive strengths of 24 MPa (3490 psi) and splitting tensile strengths of 2.5 MPa (366 psi) were measured at about 150/sup 0/C (302/sup 0/F). A full-scale production plant is described which would be capable of producing about 950 m (3120 ft) of lined 305-mm-diam (12 in.) pipe per day. Capital cost of the plant is estimated to be about $8.6 million with a calculated return on investment of 15.4%. Cost of piping a geothermal plant with PC and PC-lined steel pipe is calculated to be $1.21 million, which compares favorably with a similar plant piped with alloy steel piping at a cost of $1.33 million. Life-cycle cost analysis indicates that the cost of PC-lined steel pipe would be 82% of that of carbon steel pipe over a 20-year plant operating life.

Kaeding, A.O.

1981-12-01T23:59:59.000Z

20

Thermal Analysis of the Divertor Primary Heat Transfer System Piping During the Gas Baking Process  

SciTech Connect

A preliminary analysis has been performed examining the temperature distribution in the Divertor Primary Heat Transfer System (PHTS) piping and the divertor itself during the gas baking process. During gas baking, it is required that the divertor reach a temperature of 350 C. Thermal losses in the piping and from the divertor itself require that the gas supply temperature be maintained above that temperature in order to ensure that all of the divertor components reach the required temperature. The analysis described in this report was conducted in order to estimate the required supply temperature from the gas heater.

Yoder Jr, Graydon L [ORNL; Harvey, Karen [ORNL; Ferrada, Juan J [ORNL

2011-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Inductive gas line for pulsed lasers  

DOE Patents (OSTI)

A gas laser having a metal inlet gas feed line assembly shaped as a coil, to function as an electrical inductance and therefore high impedance to pulses of electric current applied to electrodes at opposite ends of a discharge tube of a laser, for example. This eliminates a discharge path for the laser through the inlet gas feed line. A ferrite core extends through the coil to increase the inductance of the coil and provide better electric isolation. By elimination of any discharge breakdown through the gas supply, efficiency is increased and a significantly longer operating lifetime of the laser is provided.

Benett, W.J.; Alger, T.W.

1982-09-29T23:59:59.000Z

22

Thailand's gas line underway: coating a major achievement  

SciTech Connect

Using primarily local personnel and materials, Bredero Price International's Thai pipe-coating plant has prepared some 374 miles of 34 and 28-in. pipe for service in the Gulf of Thailand gas-pipeline project. The enamel-coating shop cleaned, primed and coated all the pipe with coal-tar enamel, glass-fiber mat, felt, and a kraft-paper outer wrap; the cement-coating facility then added a concrete-weight coating to the portion of the pipe earmarked for offshore duty. Scheduled for a 1981 completion, the pipeline will initially carry 250 million CF/day to power-generating plants in Bangpakong and South Bangkok; the volume transported will eventually reach 500 million CF/day when addition offshore production is tied in to the line and an offshore compressor station added.

Hale, D.

1980-12-01T23:59:59.000Z

23

METHOD AND APPARATUS FOR THE DETECTION OF LEAKS IN PIPE LINES  

DOE Patents (OSTI)

A method is described for detecting leaks in pipe lines carrying fluid. The steps include the following: injecting a radioactive solution into a fluid flowing in the line; flushing the line clear of the radioactive solution; introducing a detector-recorder unit, comprising a radioactivity radiation detector and a recorder which records the detector signal over a time period at a substantially constant speed, into the line in association with a go-devil capable of propelling the detector-recorder unit through the line in the direction of the fluid flow at a substantia1ly constant velocity; placing a series of sources of radioactivity at predetermined distances along the downstream part of the line to make a characteristic signal on the recorder record at intervals corresponding to the location of said sources; recovering the detector-recorder unit at a downstream point along the line; transcribing the recorder record of any radioactivity detected during the travel of the detector- recorder unit in terms of distance along the line. (AEC)

Jefferson, S.; Cameron, J.F.

1961-11-28T23:59:59.000Z

24

Nuclear Maintenance Applications Center: Detection of Gas Voids in Pipe Using Guided Wave Ultrasonics  

Science Conference Proceedings (OSTI)

Nuclear power plant systems continue to be challenged by gas accumulation in both safety-related and safety-significant piping systems. In January 2008, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter 2008-01, "Managing Gas Accumulation in Emergency Core Cooling, Decay Heat Removal, and Containment Spray Systems." The Generic Letter requests that each licensee evaluate its emergency core cooling system, decay heat removal system, and containment spray system licensing basis, design, te...

2011-03-18T23:59:59.000Z

25

Ozark 260-mile gas line system completed  

Science Conference Proceedings (OSTI)

Gathering gas in the Arkoma basin of Oklahoma and Arkansas for transport to market, the 260-mile Ozark gas line system runs from southwest of McAlester, Okla., to Natural Gas Pipeline Co. of America's station at Searcy, Ark. The recently completed mainline has an initial capacity of 170 million CF/day with a maximum operating pressure of 1200 psig and a delivery pressure of 700 psig at the NGPL station. The 20-in. pipeline is API 5LX-Grade X60, 0.281-in. wall thickness for Class 1 areas, 0.344 for Class 2 areas, 0.406 for Class 3 areas, and API 5LX-Grade X52, 0.500-in. wall thickness for river crossings.

Dixon, R.R.

1982-05-01T23:59:59.000Z

26

Tempest gas turbine extends EGT product line  

SciTech Connect

With the introduction of the 7.8 MW (mechanical output) Tempest gas turbine, ECT has extended the company`s line of its small industrial turbines. The new Tempest machine, featuring a 7.5 MW electric output and a 33% thermal efficiency, ranks above the company`s single-shaft Typhoon gas turbine, rated 3.2 and 4.9 MW, and the 6.3 MW Tornado gas turbine. All three machines are well-suited for use in combined heat and power (CHP) plants, as demonstrated by the fact that close to 50% of the 150 Typhoon units sold are for CHP applications. This experience has induced EGT, of Lincoln, England, to announce the introduction of the new gas turbine prior to completion of the testing program. The present single-shaft machine is expected to be used mainly for industrial trial cogeneration. This market segment, covering the needs of paper mills, hospitals, chemical plants, ceramic industry, etc., is a typical local market. Cogeneration plants are engineered according to local needs and have to be assisted by local organizations. For this reason, to efficiently cover the world market, EGT has selected a number of associates that will receive from Lincoln completely engineered machine packages and will engineer the cogeneration system according to custom requirements. These partners will also assist the customer and dispose locally of the spares required for maintenance operations.

Chellini, R.

1995-07-01T23:59:59.000Z

27

Development of a cavitating descaling technique for on-line geothermal pipe and component cleaning and scale removal. Final report  

DOE Green Energy (OSTI)

The use of cavitation for cleaning and removing geothermal scale from pipes and system components is discussed. A study of the technical feasibility of using cavitation to remove scale is described including the preliminary fold test, the GLEF in-plant field demonstration, a production line cleaning trial, and recommendations. (MHR)

Howard, S.C.; Bohli, W.H.

1980-01-01T23:59:59.000Z

28

Vehicle tail pipe emissions. A comparison of natural gas and petrol injection  

SciTech Connect

Tests were undertaken with a Renault Express 1.4 litre converted to natural gas operation. The effect of cold starts at cold temperatures and vehicle weight on tail pipe emissions were investigated with petrol and natural gas operation over the FTP75 and the 91/441/EEC drive cycles. The results show that the emissions with natural gas are unaffected by cold temperature, unlike petrol emissions which are several times higher at -15{degree}-C than at 25{degree}-C. A crude simulation, accounting for the actual temperature, shows that the conversion of a significant quantity of light duty vehicles to natural gas operation could reduce the emissions of CO and HC by more than 90% in Switzerland. 15 refs., 17 figs., 8 tabs.

Bates, G.J.; Germano, S.

1994-10-01T23:59:59.000Z

29

Safety Bulletin 2006-02, Natural Gas Line Breaks  

NLE Websites -- All DOE Office Websites (Extended Search)

Natural Gas Line Breaks PURPOSE This Bulletin provides information on a safety concern that may impact operations at Department of Energy (DOE) facilities. Specifically, the...

30

Project Title Economic Modeling & Unconventional Gas Resource Appraisal Program Line Tough Gas  

E-Print Network (OSTI)

support to assess the economic viability of new tough gas plays (tight gas, shale gas, CBM). Project are illustrated using the US shale gas plays as case templates. Discounted cash flow models are applied1 Project Title Economic Modeling & Unconventional Gas Resource Appraisal Program Line Tough Gas

Santos, Juan

31

Heat-pipe gas-combustion system endurance test for Stirling engine. Final report, May 1990-September 1990  

SciTech Connect

Stirling Thermal Motors, Inc., (STM) has been developing a general purpose Heat Pipe Gas Combustion System (HPGC) suitable for use with the STM4-120 Stirling engine. The HPGC consists of a parallel plate recuperative preheater, a finned heat pipe evaporator and a film cooled gas combustor. A principal component of the HPGC is the heat pipe evaporator which collects and distributes the liquid sodium over the heat transfer surfaces. The liquid sodium evaporates and flows to the condensers where it delivers its latent heat. The report presents test results of endurance tests run on a Gas-Fired Stirling Engine (GFSE). Tests on a dynamometer test stand yielded 67 hours of engine operation at power levels over 10 kW (13.5 hp) with 26 hours at power levels above 15 kW (20 hp). Total testing of the engine, including both motoring tests and engine operation, yielded 245 hours of engine run time.

Mahrle, P.

1990-12-01T23:59:59.000Z

32

RF transmission line and drill/pipe string switching technology for down-hole telemetry  

DOE Patents (OSTI)

A modulated reflectance well telemetry apparatus having an electrically conductive pipe extending from above a surface to a point below the surface inside a casing. An electrical conductor is located at a position a distance from the electrically conductive pipe and extending from above the surface to a point below the surface. Modulated reflectance apparatus is located below the surface for modulating well data into a RF carrier transmitted from the surface and reflecting the modulated carrier back to the surface. A RF transceiver is located at the surface and is connected between the electrically conductive pipe and the electrical conductor for transmitting a RF signal that is confined between the electrically conductive well pipe and the electrical conductor to the modulated reflectance apparatus, and for receiving reflected data on the well from the modulated reflectance apparatus.

Clark, David D. (Santa Fe, NM); Coates, Don M. (Santa Fe, NM)

2007-08-14T23:59:59.000Z

33

On-line gas chromatographic analysis of airborne particles  

Science Conference Proceedings (OSTI)

A method and apparatus for the in-situ, chemical analysis of an aerosol. The method may include the steps of: collecting an aerosol; thermally desorbing the aerosol into a carrier gas to provide desorbed aerosol material; transporting the desorbed aerosol material onto the head of a gas chromatography column; analyzing the aerosol material using a gas chromatograph, and quantizing the aerosol material as it evolves from the gas chromatography column. The apparatus includes a collection and thermal desorption cell, a gas chromatograph including a gas chromatography column, heated transport lines coupling the cell and the column; and a quantization detector for aerosol material evolving from the gas chromatography column.

Hering, Susanne V. (Berkeley, CA); Goldstein, Allen H. (Orinda, CA)

2012-01-03T23:59:59.000Z

34

CRAD, Nuclear Facility Construction - Piping and Pipe Supports Inspection -  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Construction - Piping and Pipe Supports Construction - Piping and Pipe Supports Inspection - March 29, 2012 CRAD, Nuclear Facility Construction - Piping and Pipe Supports Inspection - March 29, 2012 March 29, 2012 Nuclear Facility Construction - Piping and Pipe Supports Inspection Criteria, Approach and Lines of Inquiry (HSS CRAD 45-52, Rev. 0) For the purpose of this criteria review and approach, this Criteria Review and Approach Document (CRAD) includes piping and pipe supports and attachments of the pipe supports to structures (concrete, structural steel, or embed plates). Pipe supports include rigid restraints, welded attachments to piping, struts, snubbers, spring cans, and constant supports. Inspection of pipe whip restraints are also included in this CRAD. Selection of nuclear facility piping systems for inspection should be

35

Regulations for Electric Transmission and Fuel Gas Transmission Lines Ten  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electric Transmission and Fuel Gas Transmission Electric Transmission and Fuel Gas Transmission Lines Ten or More Miles Long (New York) Regulations for Electric Transmission and Fuel Gas Transmission Lines Ten or More Miles Long (New York) < Back Eligibility Commercial Fuel Distributor Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Tribal Government Utility Savings Category Buying & Making Electricity Water Home Weatherization Solar Wind Program Info State New York Program Type Siting and Permitting Provider New York State Public Service Commission Any person who wishes to construct an electric or gas transmission line that is more than ten miles long must file documents describing the construction plans and potential land use and environmental impacts of the proposed transmission line. The regulations describe application and review

36

Gas insulated transmission line having tapered particle trapping ring  

DOE Patents (OSTI)

A gas-insulated transmission line includes an outer sheath, an inner conductor, insulating supports and an insulating gas. A particle-trapping ring is secured to each insulating support, and it is comprised of a central portion and two tapered end portions. The ends of the particle trapping ring have a smaller diameter than the central portion of the ring, so as to enable the use of the particle trapping ring in a curved transmission line.

Cookson, Alan H. (Pittsburgh, PA)

1982-01-01T23:59:59.000Z

37

Corrugated outer sheath gas-insulated transmission line  

DOE Patents (OSTI)

A gas-insulated transmission line includes two transmission line sections each of which are formed of a corrugated outer housing enclosing an inner high-voltage conductor disposed therein, with insulating support means supporting the inner conductor within the outer housing and an insulating gas providing electrical insulation therebetween. The outer housings in each section have smooth end sections at the longitudinal ends thereof which are joined together by joining means which provide for a sealing fixed joint.

Kemeny, George A. (Pittsburgh, PA); Cookson, Alan H. (Churchill Boro, PA)

1981-01-01T23:59:59.000Z

38

Use of Composite Pipe Materials in the Transportation of Natural Gas (INEEL/EXT-02-00992)  

NLE Websites -- All DOE Office Websites (Extended Search)

992 992 Use of Composite Pipe Materials in the Transportation of Natural Gas Patrick Laney July 2002 Idaho National Engineering and Environmental Laboratory Bechtel BWXT Idaho, LLC INEEL/EXT-02-00992 Use of Composite Pipe Materials in the Transportation of Natural Gas Sponsored by Natural Gas Pipeline Infrastructure Reliability Program National Energy Technology Laboratory INEEL Field Work Proposal # 4340-70 Prepared by: Patrick Laney Idaho National Engineering and Environmental Laboratory Idaho Falls, Idaho With Contributions From: Ian Kopp Kenway Corporation Augusta, Maine July 2002 Idaho National Engineering and Environmental Laboratory Fossil Energy Technologies Department Idaho Falls, Idaho 83415 Prepared for the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy

39

Flexible ocean upwelling pipe  

DOE Patents (OSTI)

In an ocean thermal energy conversion facility, a cold water riser pipe is releasably supported at its upper end by the hull of the floating facility. The pipe is substantially vertical and has its lower end far below the hull above the ocean floor. The pipe is defined essentially entirely of a material which has a modulus of elasticity substantially less than that of steel, e.g., high density polyethylene, so that the pipe is flexible and compliant to rather than resistant to applied bending moments. The position of the lower end of the pipe relative to the hull is stabilized by a weight suspended below the lower end of the pipe on a flexible line. The pipe, apart from the weight, is positively buoyant. If support of the upper end of the pipe is released, the pipe sinks to the ocean floor, but is not damaged as the length of the line between the pipe and the weight is sufficient to allow the buoyant pipe to come to a stop within the line length after the weight contacts the ocean floor, and thereafter to float submerged above the ocean floor while moored to the ocean floor by the weight. The upper end of the pipe, while supported by the hull, communicates to a sump in the hull in which the water level is maintained below the ambient water level. The sump volume is sufficient to keep the pipe full during heaving of the hull, thereby preventing collapse of the pipe.

Person, Abraham (Los Alamitos, CA)

1980-01-01T23:59:59.000Z

40

Main line natural gas sales to industrial users: 1978  

Science Conference Proceedings (OSTI)

Main line natural gas sales (in million cubic feet) by interstate natural gas companies to industrial users are itemized for 1974 to 1978. Information includes company name, customer name, customer's Standard Industrial Classification (SIC), the type of sale (where available and applicable), the delivery point, and the state involved in transactions. Tabulations summarize sales by SIC, by state and SIC, and by natural gas companies and SIC. Also summarized in the tables are sales by state and type (offpeak, interruptible, and not specified) for 1978. A brief narrative highlights recent trends and makes comparisons between the two most recent years. 5 tables.

Not Available

1980-01-08T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Main line natural gas sales to industrial users, 1980  

Science Conference Proceedings (OSTI)

Main line natural gas sales (in million cubic feet) by interstate natural gas companies to industrial users and other public authorities are itemized for each year from 1976 through 1980. Information includes company name, customer name, customer's Standard Industrial Classification (SIC), the type of sale (where available and applicable), the delivery point, and the state involved in transactions. Tabulations summarize sales by SIC, by State and SIC, and by Natural Gas Companies and SIC. Also summarized in the tables and sales by State and type (offpeak interruptible, and not specified) for 1980 A brief narrative highlights recent trends and makes comparisons between the two most recent years. 5 tables.

Dillard, F.B.

1981-12-01T23:59:59.000Z

42

Main-line natural gas sales to industrial users 1979  

Science Conference Proceedings (OSTI)

Main line natural gas sales by interstate natural gas companies to industrial users are itemized for 1975 to 1979. Information includes company name, customer name, customer's standard industrial classification (SIC), the type of sale (where available), the delivery point, and the state involved in transactions. Tabulations summarize sales by SIC, by state and SIC, and by natural gas companies and SIC. Also summarized are sales by state and type (offpeak, interruptible, and not specified) for the year 1979. An accompanying narrative highlights recent trends and makes comparisons between the two most recent years. 5 tables.

Not Available

1981-02-01T23:59:59.000Z

43

High voltage gas insulated transmission line with continuous particle trapping  

DOE Patents (OSTI)

This invention provides a novel high voltage gas insulated transmission line utilizing insulating supports spaced at intervals with snap-in means for supporting a continuous trapping apparatus and said trapping apparatus having perforations and cutouts to facilitate trapping of contaminating particles and system flexibility.

Cookson, Alan H. (Pittsburgh, PA); Dale, Steinar J. (Monroeville, PA)

1983-01-01T23:59:59.000Z

44

Heat pipe methanator  

DOE Patents (OSTI)

A heat pipe methanator for converting coal gas to methane. Gravity return heat pipes are employed to remove the heat of reaction from the methanation promoting catalyst, transmitting a portion of this heat to an incoming gas pre-heat section and delivering the remainder to a steam generating heat exchanger.

Ranken, William A. (Los Alamos, NM); Kemme, Joseph E. (Los Alamos, NM)

1976-07-27T23:59:59.000Z

45

The Velocity Field of Quasar Broad Emission Line Gas  

E-Print Network (OSTI)

In this Letter, the broad emission line (BEL) profiles of superluminal quasars with apparent jet velocities, $\\beta_{a}>10$, (ultraluminal QSOs, or ULQSOs hereafter) are studied as a diagnostic of the velocity field of the BEL emitting gas in quasars. The ULQSOs are useful because they satisfy a very strict kinematical constraint, their parsec scale jets must be propagating within $12^{\\circ}$ of the line of sight. We know the orientation of these objects with great certainty. The large BEL FWHM, $\\sim 3,000 \\mathrm{km/s} - 6,000 \\mathrm{km/s}$, in ULQSOs tend to indicate that the BEL gas has a larger component of axial velocity (either random or in a wind) along the jet direction than previously thought.

Brian Punsly

2007-01-25T23:59:59.000Z

46

Gas insulated transmission line with insulators having field controlling recesses  

DOE Patents (OSTI)

A gas insulated transmission line having a novel insulator for supporting an inner conductor concentrically within an outer sheath. The insulator has a recess contiguous with the periphery of one of the outer and inner conductors. The recess is disposed to a depth equal to an optimum gap for the dielectric insulating fluid used for the high voltage insulation or alternately disposed to a large depth so as to reduce the field at the critical conductor/insulator interface.

Cookson, Alan H. (Pittsburgh, PA); Pederson, Bjorn O. (Chelmsford, MA)

1984-01-01T23:59:59.000Z

47

Gas insulated transmission line having low inductance intercalated sheath  

DOE Patents (OSTI)

A gas insulated transmission line including an outer sheath, an inner conductor disposed within the outer sheath, and an insulating gas between the inner conductor and the outer sheath. The outer sheath comprises an insulating tube having first and second ends, and having interior and exterior surfaces. A first electrically conducting foil is secured to the interior surface of the insulating tube, is spirally wound from one tube end to the second tube end, and has a plurality of overlapping turns. A second electrically conducting foil is secured to the exterior surface of the insulating tube, and is spirally wound in the opposite direction from the first electrically conducting foil. By winding the foils in opposite directions, the inductances within the intercalated sheath will cancel each other out.

Cookson, Alan H. (Southboro, MA)

1978-01-01T23:59:59.000Z

48

Differential-drive in-pipe robot for moving inside urban gas pipelines  

Science Conference Proceedings (OSTI)

Pipelines for the urban gas-supply system require a robot possessing outstanding mobility and advanced control algorithms, since they are configured with various pipeline elements, such as straight pipelines, elbows, and branches. We present a comprehensive ...

Se-gon Roh; Hyouk Ryeol Choi

2005-02-01T23:59:59.000Z

49

Oil and Gas Flow Data from the Top Hat and from the Choke Line...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Flow Data from the Top Hat and from the Choke Line - XLS Oil and Gas Flow Data from the Top Hat and from the Choke Line - XLS Updated through 12:00 AM on July 10, 2010...

50

New Northeast natural gas pipeline capacity comes on-line - Today ...  

U.S. Energy Information Administration (EIA)

Solar › Energy in Brief ... Ohio to York County, Pennsylvania. 300 Line Expansion Project, operated by Tennessee Gas Pipeline Company, began service on Nov 1, 2011.

51

Variable conductance heat pipe enhancement  

SciTech Connect

This patent describes a heat pipe. It comprises a tubular hollow heat pipe having an evaporator end and an opposite condenser end, the heat pipe having a cross-sectional area and having a condenser length extending from the condenser end the condenser length including an active length where evaporated fluid condenses; an evaporatable and condensable fluid in the heat pipe for evaporating when receiving heat near the evaporation end and for condensing when giving up heat in the active length; a noncondensable gas near the condenser end and in the condenser length of the heat pipe; a restriction member fixed in the heat pipe near the condenser end, the restriction member extending only along a portion of the condenser length and being spaced away from the evaporation end of the heat pipe, the restriction member having a varied cross-sectional area along the length of the restriction member which is less than the cross-sectional area of the heat pipe for confining the gas and a portion of the fluid in the active condenser length, to an area around the restriction member and in the heat pipe; and a fixed ligament connected between the restriction member and the heat pipe for fixing the restriction member in the heat pipe, the ligament being fixed between the condenser end of the heat pipe end and an end of the restriction member which is closest to the condenser end.

Kneidel, K.E.

1991-09-03T23:59:59.000Z

52

On-Line Dissolved Gas Analysis in High-Pressure Fluid-Filled Cables  

Science Conference Proceedings (OSTI)

Highly reliable underground transmission lines are essential to deliver power consistently. Reliability may be affected as underground laminar dielectric cable circuits age and their condition degenerates. High-pressure fluid-filled (HPFF) pipe-type cable systems have been the preferred high-voltage transmission cable type in North America from the earliest transmission cable installations in the 1930s through the late 1990s and still account for the largest percentage (80%) of installed length. Although...

2009-11-17T23:59:59.000Z

53

New techniques and products solve industry problems. [New technology available for the natural gas pipeline industry  

SciTech Connect

Recently introduced technology advances in data handling, manipulation and delivery; new gas and storage marketing products; a nonintrusive pipe-crack arrester; and responsive pipe-coating mill construction show promise for cutting industry costs by increasing efficiency in pipe line construction, repair, rehabilitation, and operations. The products, services and methods described in this new technology survey include: a PC-compatible dataserver that requires no user programming; flexible, responsive gas transportation scheme; evaluation of possible further uses on brittle transmission lines for fiberglass-reinforced resin composite; new multilayer epoxy PE coating mill in Corinth, Greece, near areas where large pipe line construction and rehabilitation projects are contemplated.

Bullion, L.

1993-09-01T23:59:59.000Z

54

Pipe support  

DOE Patents (OSTI)

A pipe support for high temperature, thin-walled piping runs such as those used in nuclear systems. A section of the pipe to be supported is encircled by a tubular inner member comprised of two walls with an annular space therebetween. Compacted load-bearing thermal insulation is encapsulated within the annular space, and the inner member is clamped to the pipe by a constant clamping force split-ring clamp. The clamp may be connected to pipe hangers which provide desired support for the pipe.

Pollono, Louis P. (Hempfield Township, Hempfield County, PA)

1979-01-01T23:59:59.000Z

55

Technical Letter Report Assessment of Ultrasonic Phased Array Inspection Method for Welds in Cast Austenitic Stainless Steel Pressurizer Surge Line Piping JCN N6398, Task 1B  

SciTech Connect

Research is being conducted for the U.S. Nuclear Regulatory Commission (NRC) at the Pacific Northwest National Laboratory (PNNL) to assess the effectiveness and reliability of advanced nondestructive examination (NDE) methods for the inspection of light water reactor components. The scope of this research encompasses primary system pressure boundary materials including cast austenitic stainless steels (CASS); dissimilar metal welds; piping with corrosion-resistant cladding; weld overlays, inlays and onlays; and far-side examinations of austenitic piping welds. A primary objective of this work is to evaluate various NDE methods to assess their ability to detect, localize, and size cracks in coarse-grained steel components. In this effort, PNNL supports cooperation with Commissariat à l’Energie Atomique (CEA) to assess reliable inspection of CASS materials. The NRC Project Manager has established a cooperative effort with the Institut de Radioprotection et de Surete Nucleaire (IRSN). CEA, under funding from IRSN, are supporting collaborative efforts with the NRC and PNNL. Regarding its work on the NDE of materials, CEA is providing its modeling software (CIVA) in exchange for PNNL offering expertise and data related to phased-array detection and sizing, acoustic attenuation, and back scattering on CASS materials. This collaboration benefits the NRC because CEA performs research and development on CASS for Électricité de France (EdF). This technical letter report provides a summary of a technical evaluation aimed at assessing the capabilities of phased-array (PA) ultrasonic testing (UT) methods as applied to the inspection of welds in CASS pressurizer (PZR) surge line nuclear reactor piping. A set of thermal fatigue cracks (TFCs) was implanted into three CASS PZR surge-line specimens (pipe-to-elbow welds) that were fabricated using vintage CASS materials formed in the 1970s, and flaw responses from these cracks were used to evaluate detection and sizing performance of the PA-UT methods applied. This effort was comprised of multiple elements that included use of microstructural knowledge (dimensional analysis, grain orientation, and grain type) as well as sound field modeling to more effectively modify inspection parameters and enhance the inspection outcomes. Advanced probe design and sound field simulations were employed to enhance detection and characterization of circumferentially oriented flaws, and an assessment of lateral (circumferential) flaw localization capability and performance was also conducted. An evaluation of flaw detection, length sizing, depth sizing, and signal-to-noise ratio was performed for all flaws in the subject specimens, as a function of various inspection parameters, and finally, measurements were made to quantify and assess the baseline CASS material noise and its potential impact on flaw detection.

Diaz, Aaron A.; Cinson, Anthony D.; Crawford, Susan L.; Mathews, Royce; Moran, Traci L.; Anderson, Michael T.

2009-07-28T23:59:59.000Z

56

B Plant process piping replacement feasibility study  

SciTech Connect

Reports on the feasibility of replacing existing embedded process piping with new more corrosion resistant piping between cells and between cells and a hot pipe trench of a Hanford Site style canyon facility. Provides concepts for replacement piping installation, and use of robotics to replace the use of the canyon crane as the primary means of performing/supporting facility modifications (eg, cell lining, pipe replacement, equipment reinstallation) and operational maintenenace.

Howden, G.F.

1996-02-07T23:59:59.000Z

57

The Failure of Brass Gas Line Fittings - Programmaster.org  

Science Conference Proceedings (OSTI)

About this Abstract. Meeting, Materials Science & Technology 2013. Symposium, Failure Analysis and Prevention. Presentation Title, The Failure of Brass Gas ...

58

Pipelines to Power Lines: Gas Transportation for Electricity Generation  

Science Conference Proceedings (OSTI)

Gas-fired power generation represents a major growth market for the natural gas industry; but the large, high pressure, highly variable loads required for individual power generators can be difficult to serve. This report, cosponsored by the Gas Research Institute and EPRI, is a design stage assessment of the engineering and costs of the pipelines needed to handle these types of loads.

1995-03-10T23:59:59.000Z

59

Natural Gas Weekly Update, Printer-Friendly Version  

Gasoline and Diesel Fuel Update (EIA)

transportation costs between regions. The spot price at the New York Transcontinental Gas Pipe Line Zone 6 increased 13 cents per MMBtu to 7.13. At the NYMEX, the price of the...

60

Ceramic heat pipes for high temperature heat removal  

SciTech Connect

Difficulties in finding metal or protected metal components that exhibit both strength and corrosion resistance at high temperature have severely restricted the application of effective heat recovery techniques to process heat furnaces. A potential method of overcoming this restriction is to use heat pipes fabricated from ceramic materials to construct counterflow recuperators. A development program has been initiated to demonstrate the technical and eventually the economical feasibility of ceramic heat pipes and ceramic heat pipe recuperators. The prime candidate for heat pipe construction is SiC. Closed-end tubes of this material have been prepared by chemical vapor deposition (CVD). These tubes were lined internally with tungsten by a subsequent CVD operation, partially filled with sodium, and sealed by brazing a tungsten lined SiC plug into the open-end with a palladium--cobalt alloy. Heat pipes constructed in this manner have been successfully operated in vacuum at temperatures of 1225/sup 0/K and in air at a temperature of 1125/sup 0/K. The heat source used initially for the air testing was an induction heated metallic sleeve in thermal contact with the test unit. Subsequent testing has shown that a silicon carbide heat pipe can be successfully operated with natural gas burners providing the input heat. Methods of fabricating and testing these devices are described.

Keddy, E.S.; Ranken, W.A.

1978-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Mutual Design Considerations for Overhead AC Transmission Lines and Gas Transmission Pipelines, Volume 1: Engineering Analysis  

Science Conference Proceedings (OSTI)

This reference book presents data on an investigation into the mutual effects of electric power transmission lines and natural gas transmission pipelines sharing rights-of-way. Information is useful to both power and pipeline industry users.

1978-09-01T23:59:59.000Z

62

Regulations for Gas Transmission Lines Less than Ten Miles Long (New York)  

Energy.gov (U.S. Department of Energy (DOE))

Any person who wishes to construct a gas transmission line that is less than ten miles long must file documents describing the construction plans and potential land use and environmental impacts of...

63

Guidelines for Fuel Gas Line Cleaning Using Compressed Air or Nitrogen  

Science Conference Proceedings (OSTI)

This document lays a foundation for helping the industry to better understand common practices, design basis, and issues to consider for performing fuel gas line cleaning using compressed air or nitrogen pneumatic blow processes.

2011-12-14T23:59:59.000Z

64

SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS  

Science Conference Proceedings (OSTI)

Utilities in the U.S. operate over 75,000 km (47,000 miles) of old cast-iron pipes for gas distribution. Bell-and-spigot joints that connect pipe sections together tend to leak as these pipes age. Current repair practices are costly and highly disruptive. The objective of this program is to design, test and commercialize a robotic system capable of sealing multiple castiron bell and spigot joints from a single pipe entry point. The proposed system will perform repairs with the pipe in service by traveling through the pipe, cleaning each joint surface, and installing a stainless-steel sleeve lined with an epoxy-impregnated felt across the joint. This approach will save considerable time and labor, minimize excavation, avoid traffic disruption, and eliminate any requirement to interrupt service to customers (which would result in enormous expense to utilities). Technical challenges include: (1) repair sleeves must compensate for diametric variation and eccentricity of old cast-iron pipes; (2) the assembly must travel long distances through pipes containing debris; (3) the pipe wall must be effectively cleaned in the immediate area of the joint to assure good bonding of the sleeve; and (4) an innovative bolt-on entry fitting is required to conduct safe repair operations on live mains.

Kiran M. Kothari; Gerard T. Pittard

2005-07-01T23:59:59.000Z

65

Power Line Fault Current Coupling to Nearby Natural Gas Pipelines, Volumes 1-3  

Science Conference Proceedings (OSTI)

The Electromagnetic and Conductive Coupling Analysis of Powerlines and Pipelines (ECCAPP) computer program provides an easy-to-use method for analyzing the effects of transmission lines on gas pipelines. The program models conductive and inductive interference, enabling electrical and gas engineers to identify these effects and design mitigation systems when necessary.

1987-11-24T23:59:59.000Z

66

Promethus Hot Leg Piping Concept  

SciTech Connect

The Naval Reactors Prime Contractor Team (NRPCT) recommended the development of a gas cooled reactor directly coupled to a Brayton energy conversion system as the Space Nuclear Power Plant (SNPP) for NASA's Project Prometheus. The section of piping between the reactor outlet and turbine inlet, designated as the hot leg piping, required unique design features to allow the use of a nickel superalloy rather than a refractory metal as the pressure boundary. The NRPCT evaluated a variety of hot leg piping concepts for performance relative to SNPP system parameters, manufacturability, material considerations, and comparison to past high temperature gas reactor (HTGR) practice. Manufacturability challenges and the impact of pressure drop and turbine entrance temperature reduction on cycle efficiency were discriminators between the piping concepts. This paper summarizes the NRPCT hot leg piping evaluation, presents the concept recommended, and summarizes developmental issues for the recommended concept.

AM Girbik; PA Dilorenzo

2006-01-24T23:59:59.000Z

67

Canada's first subsea gas line conquers rocky approaches  

SciTech Connect

This paper reports on the installation of a gas pipeline system connecting Vancouver Island to the British Columbia mainland. The design challenges of this project have consisted of deep water (maximum 1,360 ft; 415 m) steep and rocky shores, and an irregular seabed topography. In addition, the project location is far from an established offshore construction market, necessitating long- distance mobilization of specialized equipment.

Yamauchi, H.M. (Westcoast Energy Inc., Vancouver (CA)); Timmermans, W.J. (Intec Engineering, Inc., Houston, TX (US))

1991-03-06T23:59:59.000Z

68

The Wardle Instability in Interstellar Shocks; 2, Gas Temperature and Line Emission  

E-Print Network (OSTI)

We have modeled the gas temperature structure in unstable C-type shocks and obtained predictions for the resultant CO and H2 rotational line emissions, using numerical simulations of the Wardle instability that were carried out by Stone (1997) and that have been described in a companion paper. We obtained results for the gas temperature distribution in -- and H2 and CO line emission from -- shocks of neutral Alfvenic Mach number 10 and velocity 20 or 40 km/sec in which the Wardle instability has saturated. Although the Wardle instability profoundly affects the density structure behind C-type shocks, most of the shock-excited molecular line emission is generated upstream of the region where the strongest effects of the instability are felt. Thus the Wardle instability has a relatively small effect upon the overall gas temperature distribution in -- and the emission line spectrum from -- C-type shocks, at least for the cases that we have considered.

Neufeld, D A; Neufeld, David A.; Stone, James M.

1997-01-01T23:59:59.000Z

69

In-Situ Measurements of Low Enrichment Uranium Holdup Process Gas Piping at K-25 - Paper for Waste Management Symposia 2010 East Tennessee Technology Park Oak Ridge, Tennessee  

SciTech Connect

This document is the final version of a paper submitted to the Waste Management Symposia, Phoenix, 2010, abstract BJC/OR-3280. The primary document from which this paper was condensed is In-Situ Measurement of Low Enrichment Uranium Holdup in Process Gas Piping at K-25 Using NaI/HMS4 Gamma Detection Systems, BJC/OR-3355. This work explores the sufficiency and limitations of the Holdup Measurement System 4 (HJVIS4) software algorithms applied to measurements of low enriched uranium holdup in gaseous diffusion process gas piping. HMS4 has been used extensively during the decommissioning and demolition project of the K-25 building for U-235 holdup quantification. The HMS4 software is an integral part of one of the primary nondestructive assay (NDA) systems which was successfully tested and qualified for holdup deposit quantification in the process gas piping of the K-25 building. The initial qualification focused on the measurement of highly enriched UO{sub 2}F{sub 2} deposits. The purpose of this work was to determine if that qualification could be extended to include the quantification of holdup in UO{sub 2}F{sub 2} deposits of lower enrichment. Sample field data are presented to provide evidence in support of the theoretical foundation. The HMS4 algorithms were investigated in detail and found to sufficiently compensate for UO{sub 2}F{sub 2} source self-attenuation effects, over the range of expected enrichment (4-40%), in the North and East Wings of the K-25 building. The limitations of the HMS4 algorithms were explored for a described set of conditions with respect to area source measurements of low enriched UO{sub 2}F{sub 2} deposits when used in conjunction with a 1 inch by 1/2 inch sodium iodide (NaI) scintillation detector. The theoretical limitations of HMS4, based on the expected conditions in the process gas system of the K-25 building, are related back to the required data quality objectives (DQO) for the NBA measurement system established for the K-25 demolition project. The combined review of the HMS software algorithms and supporting field measurements lead to the conclusion that the majority of process gas pipe measurements are adequately corrected for source self-attenuation using HMS4. While there will be instances where the UO{sub 2}F{sub 2} holdup mass presents an infinitely thick deposit to the NaI-HMS4 system these situations are expected to be infrequent. This work confirms that the HMS4 system can quantify UO{sub 2}F{sub 2} holdup, in its current configuration (deposition, enrichment, and geometry), below the DQO levels for the K-25 building decommissioning and demolition project. For an area measurement of process gas pipe in the K-25 building, if an infinitely thick UO{sub 2}F{sub 2} deposit is identified in the range of enrichment of {approx}4-40%, the holdup quantity exceeds the corresponding DQO established for the K-25 building demolition project.

Rasmussen B.

2010-01-01T23:59:59.000Z

70

Pipe connector  

DOE Patents (OSTI)

A safety test facility for testing sodium-cooled nuclear reactor components includes a reactor vessel and a heat exchanger submerged in sodium in the tank. The reactor vessel and heat exchanger are connected by an expansion/deflection pipe coupling comprising a pair of coaxially and slidably engaged tubular elements having radially enlarged opposed end portions of which at least a part is of spherical contour adapted to engage conical sockets in the ends of pipes leading out of the reactor vessel and in to the heat exchanger. A spring surrounding the pipe coupling urges the end portions apart and into engagement with the spherical sockets. Since the pipe coupling is submerged in liquid a limited amount of leakage of sodium from the pipe can be tolerated.

Sullivan, Thomas E. (Evergreen Park, IL); Pardini, John A. (Brookfield, IL)

1978-01-01T23:59:59.000Z

71

The Effect of the Environment on the Corrosion Products and Corrosion Rates on Gas Transmission Pipelines.  

E-Print Network (OSTI)

??This thesis reports a series of investigations examining external corrosion processes along gas transmission pipelines. TransCanada PipeLines Ltd. (TCPL) has developed six proposed corrosion scenarios… (more)

Sherar, Brent

2011-01-01T23:59:59.000Z

72

Gas distributor for fluidized bed coal gasifier  

DOE Patents (OSTI)

A gas distributor for distributing high temperature reaction gases to a fluidized bed of coal particles in a coal gasification process. The distributor includes a pipe with a refractory reinforced lining and a plurality of openings in the lining through which gas is fed into the bed. These feed openings have an expanding tapered shape in the downstream or exhaust direction which aids in reducing the velocity of the gas jets as they enter the bed.

Worley, Arthur C. (Mt. Tabor, NJ); Zboray, James A. (Irvine, CA)

1980-01-01T23:59:59.000Z

73

Particle trap with dielectric barrier for use in gas insulated transmission lines  

DOE Patents (OSTI)

A gas-insulated transmission line includes an outer sheath, an inner conductor within the outer sheath, insulating supports supporting the inner conductor within the outer sheath, and an insulating gas electrically insulating the inner conductor from the outer sheath. An apertured particle trapping electrode is disposed within the outer sheath, and the electrode has a pair of dielectric members secured at each longitudinal end thereof, with the dielectric members extending outwardly from the apertured electrode. 7 figs.

Dale, S.J.

1982-06-15T23:59:59.000Z

74

Particle trap with dielectric barrier for use in gas insulated transmission lines  

DOE Patents (OSTI)

A gas-insulated transmission line includes an outer sheath, an inner conductor within the outer sheath, insulating supports supporting the inner conductor within the outer sheath, and an insulating gas electrically insulating the inner conductor from the outer sheath. An apertured particle trapping electrode is disposed within the outer sheath, and the electrode has a pair of dielectric members secured at each longitudinal end thereof, with the dielectric members extending outwardly from the apertured electrode.

Dale, Steinar J. (Monroeville, PA)

1982-01-01T23:59:59.000Z

75

Renewable portfolio standards, Greenhouse gas reduction, and Long-Line transmission investments in the WECC  

Science Conference Proceedings (OSTI)

New, long-distance transmission lines to remote areas with concentrations of high-quality renewable resources can help western states meet the challenges of increasing renewable energy procurement and reducing greenhouse gas emissions more cost-effectively than reliance on local resources alone. The approach applied here to the Western Electricity Coordinating Council is useful for an initial determination of the net benefits of long-line transmission between regions with heterogeneous resource quality. (author)

Olson, Arne; Orans, Ren; Allen, Doug; Moore, Jack; Woo, C.K.

2009-11-15T23:59:59.000Z

76

On-line fast response device and method for measuring dissolved gas in a fluid  

DOE Patents (OSTI)

A method and device for the measurement of dissolved gas within a fluid. The fluid, substantially a liquid, is pumped into a pipe. The flow of the fluid is temporally restricted, creating one or more low pressure regions. A measurement indicative of trapped air is taken before and after the restriction. The amount of dissolved air is calculated from the difference between the first and second measurements. Preferably measurements indicative of trapped air is obtained from one or more pressure transducers, capacitance transducers, or combinations thereof. In the alternative, other methods such as those utilizing x-rays or gamma rays may also be used to detect trapped air. Preferably, the fluid is a hydraulic fluid, whereby dissolved air in the fluid is detected.

Tutu, Narinder Kumar (Manorville, NY)

2011-01-11T23:59:59.000Z

77

M-25, BUTT WELDS IN PROCESS PIPING  

SciTech Connect

Metal-arc and inert-gas shielded tungsten-arc processes were compared for circumferential butt welding of austenitic stainless steel process pipe. Inert-gas tungsten-arc welding was superior to other techniques. (C.J.G.)

Litman, A.P.

1958-07-10T23:59:59.000Z

78

Broadening of the spectral lines of a buffer gas and target substance in laser ablation  

SciTech Connect

The broadening of discrete spectral lines from the plasma produced in the laser ablation of metal targets in a broad pressure range (10{sup 2} - 10{sup 7} Pa) of the ambient gas (Ar, He, H{sub 2}) was studied experimentally. The behaviour of spectral line broadening for the buffer gases was found to be significantly different from that for the atoms and ions of the target material. In comparison with target atoms, the atoms of buffer gases radiate from denser plasma layers, and their spectral line profiles are complex in shape. (interaction of laser radiation with matter. laser plasma)

Kask, Nikolai E; Michurin, Sergei V [D.V. Skobel'tsyn Institute of Nuclear Physics, M.V. Lomonosov Moscow State University, Moscow (Russian Federation)

2012-11-30T23:59:59.000Z

79

Absorption and emission line studies of gas in the Milky Way halo  

E-Print Network (OSTI)

We perform a systematic study of physical properties and distribution of neutral and ionised gas in the halo of the Milky Way (MW). Beside the large neutral intermediate- and high-velocity cloud (IVC, HVC) complexes there exists a population of partly ionised gaseous structures with low-column densities that have a substantial area filling factor. The origin and nature of these structures are still under debate. We analyse the physical parameters of the MW halo gas and the relation to quasar (QSO) metal-absorption line systems at low and high redshifts. For this purpose we combine new HI 21-cm data from the EBHIS and GASS surveys with optical quasar absorption line data to study the filling factor and distribution of these gaseous clouds in the halo at HI densities below 10^19 1/cm^2. This study is important to understand the evolution of the MW in particular and the gas accretion mechanisms of galaxies in general.

Bekhti, N Ben; Winkel, B; Kerp, J; Kalberla, P; Klein, U; Murphy, M T

2010-01-01T23:59:59.000Z

80

The Bose Gas and Asymmetric Simple Exclusion Process on the Half-Line  

E-Print Network (OSTI)

In this paper we find explicit formulas for: (1) Green's function for a system of one-dimensional bosons interacting via a delta-function potential with particles confined to the positive half-line; and (2) the transition probability for the one-dimensional asymmetric simple exclusion process (ASEP) with particles confined to the nonnegative integers. These are both for systems with a finite number of particles. The formulas are analogous to ones obtained earlier for the Bose gas and ASEP on the line and integers, respectively. We use coordinate Bethe Ansatz appropriately modified to account for confinement of the particles to the half-line. As in the earlier work, the proof for the ASEP is less straightforward than for the Bose gas.

Tracy, Craig A

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Vertically aligned gas-insulated transmission line having particle traps at the inner conductor  

DOE Patents (OSTI)

Gas insulated electrical apparatus having first and second conductors separated by an insulating support within an insulating gas environment, and particle traps disposed along the surface of the high potential conductor for trapping and inactivating foreign particles which may be present within the insulating gas medium. Several embodiments of the invention were developed which are particularly suited for vertically aligned gas insulated transmission lines. The particle traps are grooves or cavities formed into the walls of the tubular inner conductor, without extending into the hollow portion of the conductor. In other embodiments, the traps are appendages or insert flanges extending from the inner conductor, with the insulator supports contacting the appendages instead of the inner conductor.

Dale, Steinar J. (Monroeville, PA)

1984-01-01T23:59:59.000Z

82

The Nature of Interstellar Gas toward the Pleiades Revealed in Absorption Lines  

E-Print Network (OSTI)

We present high-resolution, high signal to noise absorption-line observations of CN, Ca II, Ca I, CH^+, and CH along twenty lines of sight toward members of the Pleiades. The acquired data enable the most detailed study to date of the interaction between cluster stars and the surrounding interstellar gas. Total equivalent widths are consistent with previous investigations except where weaker features are detected owing to our greater sensitivity. Mean b-values for the molecular species indicate that toward most of the Pleiades CH is associated with the production of CH^+ rather than CN. An analysis of radial velocities reveals a kinematic distinction between ionized atomic gas and molecular and neutral gas. Molecular components are found with velocities in the local standard of rest of either ~ +7 km s^-1 or ~ +9.5 km s^-1, with the higher-velocity components associated with the strongest absorption. Atomic gas traced by Ca II shows a strong central component at v_LSR ~ +7 km s^-1 exhibiting velocity gradients indicative of cloud-cluster interactions. Gas density estimates derived from measured CH/CH^+ column density ratios show good agreement with those inferred from H_2 rotational populations, yielding typical values of n ~ 50 cm^-3. Our models do not include the important time-dependent effects on CH^+ formation which may ultimately be needed to extract physical conditions in these clouds.

A. M. Ritchey; M. Martinez; K. Pan; S. R. Federman; D. L. Lambert

2006-06-27T23:59:59.000Z

83

Hybrid particle traps and conditioning procedure for gas insulated transmission lines  

DOE Patents (OSTI)

A gas insulated transmission line includes an outer sheath, an inner condor within the outer sheath, insulating supports supporting the inner conductor within the outer sheath, and an insulating gas electrically insulating the inner conductor from the outer sheath. An apertured particle trapping ring is disposed within the outer sheath, and the trapping ring has a pair of dielectric members secured at each longitudinal end thereof, with the dielectric members extending outwardly from the trapping ring along an arc. A support sheet having an adhesive coating thereon is secured to the trapping ring and disposed on the outer sheath within the low field region formed between the trapping ring and the outer sheath. A conditioning method used to condition the transmission line prior to activation in service comprises applying an AC voltage to the inner conductor in a plurality of voltage-time steps, with the voltage-time steps increasing in voltage magnitude while decreasing in time duration.

Dale, Steinar J. (Monroeville, PA); Cookson, Alan H. (Churchill, PA)

1982-01-01T23:59:59.000Z

84

Heat pipe turbine vane cooling  

SciTech Connect

The applicability of using heat pipe principles to cool gas turbine vanes is addressed in this beginning program. This innovative concept involves fitting out the vane interior as a heat pipe and extending the vane into an adjacent heat sink, thus transferring the vane incident heat transfer through the heat pipe to heat sink. This design provides an extremely high heat transfer rate and a uniform temperature along the vane due to the internal change of phase of the heat pipe working fluid. Furthermore, this technology can also eliminate hot spots at the vane leading and trailing edges and increase the vane life by preventing thermal fatigue cracking. There is also the possibility of requiring no bleed air from the compressor, and therefore eliminating engine performance losses resulting from the diversion of compressor discharge air. Significant improvement in gas turbine performance can be achieved by using heat pipe technology in place of conventional air cooled vanes. A detailed numerical analysis of a heat pipe vane will be made and an experimental model will be designed in the first year of this new program.

Langston, L.; Faghri, A. [Connecticut Univ., Storrs, CT (United States). Dept. of Mechanical Engineering

1995-12-31T23:59:59.000Z

85

Fundamental heat transfer experiments of heat pipes for turbine cooling  

SciTech Connect

Fundamental heat transfer experiments were carried out for three kinds of heat pipes that may be applied to turbine cooling in future aero-engines. In the turbine cooling system with a heat pipe, heat transfer rate and start-up time of the heat pipe are the most important performance criteria to evaluate and compare with conventional cooling methods. Three heat pipes are considered, called heat pipe A, B, and C, respectively. All heat pipes have a stainless steel shell and nickel sintered powder metal wick. Sodium (Na) was the working fluid for heat pipes A and B; heat pipe C used eutectic sodium-potassium (NaK). Heat pipes B and C included noncondensible gas for rapid start-up. There were fins on the cooling section of heat pipes. In the experiments, an infrared image furnace supplied heat to the heat pipe simulating turbine blade surface conditions. In the results, heat pipe B demonstrated the highest heat flux of 17 to 20 W/cm{sup 2}. The start-up time was about 6 minutes for heat pipe B and about 6 minutes for heat pipe A. Thus, adding noncondensible gas effectively reduced start-up time. Although NaK is a liquid phase at room temperature, the start-up time of heat pipe C (about 7 to 8 minutes) was not shorter than the heat pipe B. The effect of a gravitational force on heat pipe performance was also estimated by inclining the heat pipe at an angle of 90 deg. There was no significant gravitational dependence on heat transport for heat pipes including noncondensible gas.

Yamawaki, S. [Ishikawajima-Harima Heavy Industries Co., Ltd., Tokyo (Japan); Yoshida, T.; Taki, M.; Mimura, F. [National Aerospace Lab., Tokyo (Japan)

1998-07-01T23:59:59.000Z

86

Heat Pipes: An Industrial Application  

E-Print Network (OSTI)

This paper reviews the basics of heat pipe exchangers. Included are how they are constructed, how they operate, where they have application, and various aspects of evaluating a potential application. After discussing the technical aspects of heat pipe exchangers, an industrial case history is presented. The case history involves a retrofit project which added heat pipes to five natural draft process heaters with a combined heat duty of 150 M Btu/hr. A heat recovery of 15 M Btu/hr has resulted from the flue gas/combustion air interchange. The paper will include design considerations, and operating and maintenance history since early 1980. A second application for heat pipes with a 12 M Btu/hr duty installed in 1983 will also be discussed.

Murray, F.

1984-01-01T23:59:59.000Z

87

Pipeline and Gas Journal`s 1998 annual pipeline directory and equipment guide  

Science Conference Proceedings (OSTI)

The tables provide information on line pipe sizes, walls, grades, and manufacturing processes. Data are presented by manufacturer within each country. Also tabulated are engineering and construction service companies, crude oil pipeline companies, products pipeline companies, natural gas pipeline companies, gas distribution companies, and municipal gas systems in the US. There is also a Canadian and an international directory.

NONE

1998-09-01T23:59:59.000Z

88

The Nature of Interstellar Gas toward the Pleiades Revealed in Absorption Lines  

E-Print Network (OSTI)

We present high-resolution, high signal to noise absorption-line observations of CN, Ca II, Ca I, CH^+, and CH along twenty lines of sight toward members of the Pleiades. The acquired data enable the most detailed study to date of the interaction between cluster stars and the surrounding interstellar gas. Total equivalent widths are consistent with previous investigations except where weaker features are detected owing to our greater sensitivity. Mean b-values for the molecular species indicate that toward most of the Pleiades CH is associated with the production of CH^+ rather than CN. An analysis of radial velocities reveals a kinematic distinction between ionized atomic gas and molecular and neutral gas. Molecular components are found with velocities in the local standard of rest of either ~ +7 km s^-1 or ~ +9.5 km s^-1, with the higher-velocity components associated with the strongest absorption. Atomic gas traced by Ca II shows a strong central component at v_LSR ~ +7 km s^-1 exhibiting velocity gradient...

Ritchey, A M; Pan, K; Federman, S R; Lambert, D L

2006-01-01T23:59:59.000Z

89

The Wardle Instability in Interstellar Shocks: II. Gas Temperature and Line Emission  

E-Print Network (OSTI)

We have modeled the gas temperature structure in unstable C-type shocks and obtained predictions for the resultant CO and H2 rotational line emissions, using numerical simulations of the Wardle instability that were carried out by Stone (1997) and that have been described in a companion paper. Our model for the thermal balance of the gas includes ion-neutral frictional heating; compressional heating; radiative cooling due to rotational and rovibrational transitions of the molecules CO, H2O and H2; and gas-grain collisional cooling. We obtained results for the gas temperature distribution in – and H2 and CO line emission from – shocks of neutral Alfvenic Mach number 10 and velocity 20 or 40 km s ?1 in which the Wardle instability has saturated. Both two- and three-dimensional simulations were carried out for shocks in which the preshock magnetic field is perpendicular to the shock propagation direction; and a 2-D simulation was carried out for the case in which the magnetic field is obliquely oriented with respect to the shock propagation direction. Although the Wardle

David A. Neufeld; James M. Stone

1997-01-01T23:59:59.000Z

90

SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS  

Science Conference Proceedings (OSTI)

Utilities in the U.S. operate over 75,000 km (47,000 miles) of old cast-iron pipes for gas distribution. The bell-and-spigot joints that connect pipe sections together tend to leak as these pipes age. Current repair practices are costly and highly disruptive. The objective of this program is to design, test and commercialize a robotic system capable of sealing multiple castiron bell and spigot joints from a single pipe entry point. The proposed system will perform repairs while the pipe remains in service by traveling through the pipe, cleaning each joint surface, and installing a stainless-steel sleeve lined with an epoxy-impregnated felt across the joint. This approach will save considerable time and labor, avoid traffic disruption, and eliminate any requirement to interrupt service to customers (which would result in enormous expense to utilities). Technical challenges include: (1) repair sleeves must compensate for diametric variation and eccentricity of cast-iron pipes; (2) the assembly must travel long distances through pipes containing debris; (3) the pipe wall must be effectively cleaned in the immediate area of the joint to assure good bonding of the sleeve; and (4) an innovative bolt-on entry fitting is required to conduct repair operations on live mains. The development effort is divided into eleven tasks. Task 1 (Program Management) and Task 2 (Establishment of Detailed Design Specifications) were completed in prior quarters while Task 3 (Design and Fabricate Ratcheting Stainless-Steel Repair Sleeves) has progressed to installing prototype sleeves in cast iron test pipe segments. Efforts in this quarter continued to focus on Tasks 4-8, with significant progress made in each. Task 4 (Design, Fabricate and Test Patch Setting Robotic Train) progressed to the design of the control electronics and pneumatic system to inflate the bladder robotic patch setting module. Task 5 (Design & Fabricate Pipe-Wall Cleaning Robot Train with Pan/Zoom/Tilt Camera) continued with additional in-pipe testing required to optimize the design of the robot elements and surface control electronics and software. Task 6 (Design & Build Surface Control and Monitoring System) has been completed with the control and computer display functions being operated through LabView. Task 7 (Design & Fabricate Large Diameter Live Access System) progressed to completing the detailed design of the entry fitting for 12-inch diameter cast iron pipe. The fitting is now being manufactured. The 12-inch ball valve for allowing no-blow access was also procured. Task 8 (System Integration and Laboratory Validation) continued with the development of the robot module inter-connects and of a master LabView-based system display and control software.

Kiran M Kothari; Gerard T. Pittard

2004-07-01T23:59:59.000Z

91

SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS  

SciTech Connect

Utilities in the U.S. operate over 75,000 km (47,000 miles) of old cast-iron pipes for gas distribution. The bell-and-spigot joints that connect pipe sections together tend to leak as these pipes age. Current repair practices are costly and highly disruptive. The objective of this program is to design, test and commercialize a robotic system capable of sealing multiple cast iron bell and spigot joints from a single pipe entry point. The proposed system will perform repairs while the pipe remains in service by traveling through the pipe, cleaning each joint surface, and installing a stainless-steel sleeve lined with an epoxy-impregnated felt across the joint. This approach will save considerable time and labor, avoid traffic disruption, and eliminate any requirement to interrupt service to customers (which would result in enormous expense to utilities). Technical challenges include: (1) repair sleeves must compensate for diametric variation and eccentricity of cast-iron pipes; (2) the assembly must travel long distances through pipes containing debris; (3) the pipe wall must be effectively cleaned in the immediate area of the joint to assure good bonding of the sleeve; and (4) an innovative bolt-on entry fitting is required to conduct repair operations on live mains. The development effort is divided into eleven tasks. Task 1--Program Management and Task 2--were completed in prior quarters while Task 3--Design and Fabricate Ratcheting Stainless-Steel Repair Sleeves has progressed to installing prototype sleeves in cast iron test pipe segments. Efforts in this quarter continued to focus on Tasks 4--8, with significant progress made in each. Task 4 (Design, Fabricate and Test Patch Setting Robotic Train) progressed to the design of the control electronics and pneumatic system to inflate the bladder robotic patch setting module. Task 5 (Design & Fabricate Pipe-Wall Cleaning Robot Train with Pan/Zoom/Tilt Camera) continued with additional in-pipe testing required to optimize the design of the robot elements and surface control electronics and software. Task 6 (Design & Build Surface Control and Monitoring System) has been completed with the control and computer display functions being operated through LabView. Task 7 (Design & Fabricate Large Diameter Live Access System) progressed to the design, fabrication and testing of a entry fitting in a 4-inch prototype and is now being used to complete drawings for use in 12-inch diameter pipe. Task 8--System Integration and Laboratory Validation continued developing the robot module inter-connects and development of a master LabView-based system display and control software.

Kiran M. Kothari, Gerard T. Pittard

2004-01-01T23:59:59.000Z

92

SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS  

Science Conference Proceedings (OSTI)

Utilities in the U.S. operate over 75,000 km (47,000 miles) of old cast-iron pipes for gas distribution. The bell-and-spigot joints that connect pipe sections together tend to leak as these pipes age. Current repair practices are costly and highly disruptive. The objective of this program is to design, test and commercialize a robotic system capable of sealing multiple cast-iron bell and spigot joints from a single pipe entry point. The proposed system will perform repairs while the pipe remains in service by traveling through the pipe, cleaning each joint surface, and installing a stainless-steel sleeve lined with an epoxy-impregnated felt across the joint. This approach will save considerable time and labor, avoid traffic disruption, and eliminate any requirement to interrupt service to customers (which would result in enormous expense to utilities). Technical challenges include: (1) repair sleeves must compensate for diametric variation and eccentricity of cast-iron pipes; (2) the assembly must travel long distances through pipes containing debris; (3) the pipe wall must be effectively cleaned in the immediate area of the joint to assure good bonding of the sleeve; and (4) an innovative bolt-on entry fitting is required to conduct repair operations on live mains. The development effort is divided into eleven tasks. Task 1--Program Management and Task 2--were completed in prior quarters while Task 3--Design and Fabricate Ratcheting Stainless-Steel Repair Sleeves has progressed to installing prototype sleeves in cast iron test pipe segments. Efforts in this quarter continued to focus on Tasks 4--8, with significant progress made in each. Task 4 (Design, Fabricate and Test Patch Setting Robotic Train) progressed to the design of the control electronics and pneumatic system to inflate the bladder robotic patch setting module. Task 5 (Design & Fabricate Pipe-Wall Cleaning Robot Train with Pan/Zoom/Tilt Camera) continued with additional in-pipe testing required to optimize the design of the robot elements and surface control electronics and software. Task 6 (Design & Build Surface Control and Monitoring System) has been completed with the control and computer display functions being operated through LabView. Task 7 (Design & Fabricate Large Diameter Live Access System) progressed to completing the detailed design of the entry fitting for 12-inch diameter cast iron pipe. The fitting is now being placed into manufacture. Task 8--System Integration and Laboratory Validation continued developing the robot module inter-connects and development of a master LabView-based system display and control software.

Kiran M. Kothari; Gerard T. Pittard

2004-04-01T23:59:59.000Z

93

Life Assessment Methods for Power Plant Piping and Tubing  

Science Conference Proceedings (OSTI)

...life prediction High-temperature crack growth methods ):36, Ref 35Similar to gas turbine blades, piping and tubing in steamlines, heaters,

94

Ten Years of Compressed Natural Gas (CNG) Operations at SunLine Transit Agency: April 2003--December 2004  

Science Conference Proceedings (OSTI)

This report focuses on the lesson learned at the SunLine Transit Agency after it converted in 1994 its entire operating transit bus fleet to compressed natural gas (CNG).

Chandler, K.

2006-01-01T23:59:59.000Z

95

Vapor spill pipe monitor  

DOE Patents (OSTI)

The invention is a method and apparatus for continually monitoring the composition of liquefied natural gas flowing from a spill pipe during a spill test by continually removing a sample of the LNG by means of a probe, gasifying the LNG in the probe, and sending the vaporized LNG to a remote ir gas detector for analysis. The probe comprises three spaced concentric tubes surrounded by a water jacket which communicates with a flow channel defined between the inner and middle, and middle and outer tubes. The inner tube is connected to a pump for providing suction, and the probe is positioned in the LNG flow below the spill pipe with the tip oriented partly downward so that LNG is continuously drawn into the inner tube through a small orifice. The probe is made of a high thermal conductivity metal. Hot water is flowed through the water jacket and through the flow channel between the three tubes to provide the necessary heat transfer to flash vaporize the LNG passing through the inner channel of the probe. The gasified LNG is transported through a connected hose or tubing extending from the probe to a remote ir sensor which measures the gas composition.

Bianchini, G.M.; McRae, T.G.

1983-06-23T23:59:59.000Z

96

Particle trap to sheath contact for a gas-insulated transmission line having a corrugated outer conductor  

DOE Patents (OSTI)

A particle trap to outer elongated conductor or sheath contact for gas-insulated transmission lines. The particle trap to outer sheath contact of the invention is applicable to gas-insulated transmission lines having either corrugated or non-corrugated outer sheaths. The contact of the invention includes an electrical contact disposed on a lever arm which in turn is rotatably disposed on the particle trap and biased in a direction to maintain contact between the electrical contact and the outer sheath.

Fischer, William H. (Pittsburgh, PA); Cookson, Alan H. (Pittsburgh, PA); Yoon, Kue H. (Pittsburgh, PA)

1984-04-10T23:59:59.000Z

97

Semi-flexible gas-insulated transmission line using electric field stress shields  

DOE Patents (OSTI)

A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by use of main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. The flexing elements and the stress shields may also be utilized in connection with a plug and socket arrangement for providing electrical connection between main conductor sections. 10 figs.

Cookson, A.H.; Dale, S.J.; Bolin, P.C.

1982-12-28T23:59:59.000Z

98

Semi-flexible gas-insulated transmission line using sandwiched discs for intermittent flexing joints  

DOE Patents (OSTI)

A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by the use of main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. The flexing elements are formed by sandwiching together, by fusing, a pair of thin hollow discs which are fixedly secured to both the main conductor sections and the conductor hub section. 4 figs.

Kommineni, P.R.

1983-02-15T23:59:59.000Z

99

Semi-flexible gas-insulated transmission line using sandwiched discs for intermittent flexing joints  

DOE Patents (OSTI)

A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by the use of main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. The flexing elements are formed by sandwiching together, by fusing, a pair of thin hollow discs which are fixedly secured to both the main conductor sections and the conductor hub section.

Kommineni, Prasad R. (Westboro, MA)

1983-02-15T23:59:59.000Z

100

Semi-flexible gas-insulated transmission line using electric field stress shields  

DOE Patents (OSTI)

A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by use of main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. The flexing elements and the stress shields may also be utilized in connection with a plug and socket arrangement for providing electrical connection between main conductor sections.

Cookson, Alan H. (Churchill Borough, PA); Dale, Steinar J. (Monroeville, PA); Bolin, Philip C. (Wilkins Township, Allegheny County, PA)

1982-12-28T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Commercial potential of natural gas storage in lined rock caverns (LRC)  

SciTech Connect

The geologic conditions in many regions of the United States will not permit the development of economical high-deliverability gas storage in salt caverns. These regions include the entire Eastern Seaboard; several northern states, notably Minnesota and Wisconsin; many of the Rocky Mountain States; and most of the Pacific Northwest. In late 1997, the United States Department of Energy (USDOE) Federal Energy Technology Center engaged Sofregaz US to investigate the commercialization potential of natural gas storage in Lined Rock Caverns (LRC). Sofregaz US teamed with Gaz de France and Sydkraft, who had formed a consortium, called LRC, to perform the study for the USDOE. Underground storage of natural gas is generally achieved in depleted oil and gas fields, aquifers, and solution-mined salt caverns. These storage technologies require specific geologic conditions. Unlined rock caverns have been used for decades to store hydrocarbons - mostly liquids such as crude oil, butane, and propane. The maximum operating pressure in unlined rock caverns is limited, since the host rock is never entirely impervious. The LRC technology allows a significant increase in the maximum operating pressure over the unlined storage cavern concept, since the gas in storage is completely contained with an impervious liner. The LRC technology has been under development in Sweden by Sydkraft since 1987. The development process has included extensive technical studies, laboratory testing, field tests, and most recently includes a storage facility being constructed in southern Sweden (Skallen). The LRC development effort has shown that the concept is technically and economically viable. The Skallen storage facility will have a rock cover of 115 meters (375 feet), a storage volume of 40,000 cubic meters (250,000 petroleum barrels), and a maximum operating pressure of 20 MPa (2,900 psi). There is a potential for commercialization of the LRC technology in the United States. Two regions were studied in some detail - the Northeast and the Southeast. The investment cost for an LRC facility in the Northeast is approximately $182 million and $343 million for a 2.6-billion cubic foot (bcf) working gas facility and a 5.2-bcf working gas storage facility, respectively. The relatively high investment cost is a strong function of the cost of labor in the Northeast. The labor union-related rules and requirements in the Northeast result in much higher underground construction costs than might result in Sweden, for example. The LRC technology gas storage service is compared to other alternative technologies. The LRC technology gas storage service was found to be competitive with other alternative technologies for a variety of market scenarios.

1999-11-01T23:59:59.000Z

102

Flexible gas insulated transmission line having regions of reduced electric field  

DOE Patents (OSTI)

A gas insulated transmission line having radially flexible field control means for reducing the electric field along the periphery of the inner conductor at predetermined locations wherein the support insulators are located. The radially flexible field control means of the invention includes several structural variations of the inner conductor, wherein careful controlling of the length to depth of surface depressions produces regions of reduced electric field. Several embodiments of the invention dispose a flexible connector at the predetermined location along the inner conductor where the surface depressions that control the reduced electric field are located.

Cookson, Alan H. (Pittsburgh, PA); Fischer, William H. (Wilkins Township, Allegheny County, PA); Yoon, Kue H. (Pittsburgh, PA); Meyer, Jeffry R. (Penn Hills Township, Allegheny County, PA)

1983-01-01T23:59:59.000Z

103

Development and Manufacture of Cost-Effective Composite Drill Pipe  

SciTech Connect

Advanced Composite Products and Technology, Inc. (ACPT) has developed composite drill pipe (CDP) that matches the structural and strength properties of steel drill pipe, but weighs less than 50 percent of its steel counterpart. Funding for the multiyear research and development of CDP was provided by the U.S. Department of Energy Office of Fossil Energy through the Natural Gas and Oil Projects Management Division at the National Energy Technology Laboratory (NETL). Composite materials made of carbon fibers and epoxy resin offer mechanical properties comparable to steel at less than half the weight. Composite drill pipe consists of a composite material tube with standard drill pipe steel box and pin connections. Unlike metal drill pipe, composite drill pipe can be easily designed, ordered, and produced to meet specific requirements for specific applications. Because it uses standard joint connectors, CDP can be used in lieu of any part of or for the entire steel drill pipe section. For low curvature extended reach, deep directional drilling, or ultra deep onshore or offshore drilling, the increased strength to weight ratio of CDP will increase the limits in all three drilling applications. Deceased weight will reduce hauling costs and increase the amount of drill pipe allowed on offshore platforms. In extreme extended reach areas and high-angle directional drilling, drilling limits are associated with both high angle (fatigue) and frictional effects resulting from the combination of high angle curvature and/or total weight. The radius of curvature for a hole as small as 40 feet (12.2 meters) or a build rate of 140 degrees per 100 feet is within the fatigue limits of specially designed CDP. Other properties that can be incorporated into the design and manufacture of composite drill pipe and make it attractive for specific applications are corrosion resistance, non-magnetic intervals, and abrasion resistance coatings. Since CDP has little or no electromagnetic force fields up to 74 kilohertz (KHz), a removable section of copper wire can be placed inside the composite pipe to short the tool joints electrically allowing electromagnetic signals inside the collar to induce and measure the same within the rock formation. By embedding a pair of wires in the composite section and using standard drill pipe box and pin ends equipped with a specially developed direct contact joint electrical interface, power can be supplied to measurement-while-drilling (MWD) and logging-while-drilling (LWD) bottom hole assemblies. Instantaneous high-speed data communications between near drill bit and the surface are obtainable utilizing this 'smart' drilling technology. The composite drill pipe developed by ACPT has been field tested successfully in several wells nationally and internationally. These tests were primarily for short radius and ultra short radius directional drilling. The CDP in most cases performed flawlessly with little or no appreciable wear. ACPT is currently marketing a complete line of composite drill collars, subs, isolators, casing, and drill pipe to meet the drilling industry's needs and tailored to replace metal for specific application requirements.

James C. Leslie

2008-12-31T23:59:59.000Z

104

Gas Generation Testing of Neptunium Oxide Generated Using the HB-Line Phase IIFlowsheet  

DOE Green Energy (OSTI)

The hydrogen (H{sub 2}) gas generation rate for neptunium dioxide (NpO{sub 2}) samples produced on a laboratory scale using the HB-Line Phase II flowsheet has been measured following exposure to 75% relative humidity (RH). As expected, the observed H{sub 2} generation rates for these samples increase with increasing moisture content. A maximum H{sub 2} generation rate of 1.8 x 10{sup -6} moles per day per kilogram (mol {center_dot} day{sup -1} kg{sup -1}) was observed for NpO{sub 2} samples with approximately one and one-half times (1 1/2 X) the expected specific surface area (SSA) for the HB-Line Phase II product. The SSA of NpO{sub 2} samples calcined at 650 C is similar to plutonium dioxide (PuO{sub 2}) calcined at 950 C according to the Department of Energy (DOE) standard for packaging and storage of PuO{sub 2}. This low SSA of the HB-Line Phase II product limits moisture uptake to less than 0.2 weight percent (wt %) even with extended exposure to 75% RH.

Duffey, J

2003-08-29T23:59:59.000Z

105

Analysis of fission gas release kinetics by on-line mass spectrometry  

SciTech Connect

The release of fission gas (Xe and Kr) and helium out of nuclear fuel materials in normal operation of a nuclear power reactor can constitute a strong limitation of the fuel lifetime. Moreover, radioactive isotopes of Xe and Kr contribute significantly to the global radiological source term released in the primary coolant circuit in case of accidental situations accompanied by fuel rod loss of integrity. As a consequence, fission gas release investigation is of prime importance for the nuclear fuel cycle economy, and is the driven force of numerous R and D programs. In this domain, for solving current fuel behavior understanding issues, preparing the development of new fuels (e.g. for Gen IV power systems) and for improving the modeling prediction capability, there is a marked need for innovations in the instrumentation field, mainly for: . Quantification of very low fission gas concentrations, released from fuel sample and routed in sweeping lines. Monitoring of quick gas release variations by quantification of elementary release during a short period of time. Detection of a large range of atomic masses (e.g. H{sub 2}, HT, He, CO, CO{sub 2}, Ne, Ar, Kr, Xe), together with a performing separation of isotopes for Xe and Kr elements. Coupling measurement of stable and radioactive gas isotopes, by using in parallel mass spectrometry and gamma spectrometry techniques. To fulfill these challenging needs, a common strategy for analysis equipment implementation has been set up thanks to a recently launched collaboration between the CEA and the Univ. of Provence, with the technological support of the Liverpool Univ.. It aims at developing a chronological series of mass spectrometer devices based upon mass filter and 2D/3D ion traps with Fourier transform operating mode and having increasing levels of performances to match the previous challenges for out-of pile and in-pile experiments. The final objective is to install a high performance online mass spectrometer coupled to a gamma spectrometer in the fission product laboratory of the future Jules Horowitz Material Test Reactor. An intermediate step will consist of testing first equipment on an existing experimental facility in the LECA-STAR Hot Cell Laboratory of the CEA Cadarache. This paper presents the scientific and operational stakes linked to fission gas issues, resumes the current state of art for analyzing them in nuclear facilities, then presents the skills gathered through this collaboration to overcome technological bottlenecks. Finally it describes the implementation strategy in nuclear research facilities of the CEA Cadarache. (authors)

Zerega, Y.; Reynard-Carette, C. [Univ. of Provence, Laboratoire Chimie Provence, UMR 6264, Avenue escadrille Normandie - Niemen, F-13397 Marseille (France); Parrat, D. [CEA, Nuclear Energy Div. DEN, CEA Cadarache, F-13108 Saint-Paul-lez-Durance (France); Carette, M. [Univ. of Provence, Laboratoire Chimie Provence, UMR 6264, Avenue escadrille Normandie - Niemen, F-13397 Marseille (France); Brkic, B. [Univ. of Liverpool, Dept. of Electrical Engineering and Electronics, Liverpool L69 3BX (United Kingdom); Lyoussi, A.; Bignan, G. [CEA, Nuclear Energy Div. DEN, CEA Cadarache, F-13108 Saint-Paul-lez-Durance (France); Janulyte, A.; Andre, J. [Univ. of Provence, Laboratoire Chimie Provence, UMR 6264, Avenue escadrille Normandie - Niemen, F-13397 Marseille (France); Pontillon, Y.; Ducros, G. [CEA, Nuclear Energy Div. DEN, CEA Cadarache, F-13108 Saint-Paul-lez-Durance (France); Taylor, S. [Univ. of Liverpool, Dept. of Electrical Engineering and Electronics, Liverpool L69 3BX (United Kingdom)

2011-07-01T23:59:59.000Z

106

High temperature heat pipe experiments in low earth orbit  

SciTech Connect

Although high temperature, liquid metal heat pipe radiators have become a standard component on most high power space power system designs, there is no experimental data on the operation of these heat pipes in a zero gravity or micro-gravity environment. Experiments to benchmark the transient and steady state performance of prototypical heat pipe space radiator elements are in preparation for testing in low earth orbit. It is anticipated that these heat pipes will be tested aborad the Space Shuttle in 1995. Three heat pipes will be tested in a cargo bay Get Away Special (GAS) canister. The heat pipes are SST/potassium, each with a different wick structure; homogeneous, arterial, and annular gap, the heat pipes have been designed, fabricated, and ground tested. In this paper, the heat pipe designs are specified, and transient and steady-state ground test data are presented.

Woloshun, K.; Merrigan, M.A.; Sena, J.T. (Los Alamos National Lab., NM (United States)); Critchley, E. (Phillips Lab., Kirtland AFB, NM (United States))

1993-01-01T23:59:59.000Z

107

Application of Heat Pipes to the ATSF Spacecraft  

SciTech Connect

The Applications Technology Satellite (ATS) heat pipe program is an extensive effort requiring the fabrication and testing of more than 300 flight qualified heat pipes. The spacecraft itself contains 55 heat pipes in three configurations and 13 sizes. The design selected for ATS was an axially groved 6061 aluminum-ammonia heat pipe. Several developmental programs and extensive testing, including individual heat pipes, heat pipes bonded into honeycomb panels, and a large number of life tests, were included within the overall effort. Results are presented for the thermal modeling of the heat pipes with the spacecraft. Results of thermal-vacuum testing of a thermal structural model and sounding rocket testing of the ATS axially grooved pipe are also discussed. Several problems including hydrogen gas generation, were encountered during the course of the program. The steps taken to solve these problems may be applicable to future programs.

Berger, M.E.; Kelly, W.H.

1973-01-01T23:59:59.000Z

108

High temperature heat pipe experiments in low earth orbit  

SciTech Connect

Although high temperature, liquid metal heat pipe radiators have become a standard component on most high power space power system designs, there is no experimental data on the operation of these heat pipes in a zero gravity or micro-gravity environment. Experiments to benchmark the transient and steady state performance of prototypical heat pipe space radiator elements are in preparation for testing in low earth orbit. It is anticipated that these heat pipes will be tested aborad the Space Shuttle in 1995. Three heat pipes will be tested in a cargo bay Get Away Special (GAS) canister. The heat pipes are SST/potassium, each with a different wick structure; homogeneous, arterial, and annular gap, the heat pipes have been designed, fabricated, and ground tested. In this paper, the heat pipe designs are specified, and transient and steady-state ground test data are presented.

Woloshun, K.; Merrigan, M.A.; Sena, J.T. [Los Alamos National Lab., NM (United States); Critchley, E. [Phillips Lab., Kirtland AFB, NM (United States)

1993-02-01T23:59:59.000Z

109

Novel heat pipe combination  

SciTech Connect

The basic heat pipe principle is employed in a heat pipe combination wherein two heat pipes are combined in opposing relationship to form an integral unit; such that the temperature, heat flow, thermal characteristics, and temperature-related parameters of a monitored environment or object exposed to one end of the heat pipe combination can be measured and controlled by controlling the heat flow of the opposite end of the heat pipe combination.

Arcella, F.G.

1978-01-10T23:59:59.000Z

110

Analysis of the potential for automating EIA-0129 main line natural gas sales to industrial users  

Science Conference Proceedings (OSTI)

This report presents the results of a review of the publication, Main Line Natural Gas Sales to Industrial Users, to examine alternative approaches to data handling. Preparation of the publication is divided into three phases: collection, processing, and production. Much of the information presented in the report is generated by manually searching the reporting schedule and performing arithmetic calculations to determine sales totals and price averages. Simple alphabetic searches and computational algorithms could be implemented to greatly simplify the production of this report. In particular, the most quantitative phase of developing the report, that of processing the data, has aspects which present possibilities for automation. Potential options include total automation, in which all calculations, checking and table construction are performed by the system; partial automation, in which calculations are processed by the system but preparation of tables is performed by hand; and retention of the current manual system.

Not Available

1982-05-10T23:59:59.000Z

111

Conductor load bearing roller for a gas-insulated transmission line having a corrugated outer conductor  

DOE Patents (OSTI)

A gas-insulated transmission line includes a corrugated outer conductor, an inner conductor disposed within and insulated from the outer conductor by means of support insulators and an insulating gas, and a transport device for supporting and permitting movement of the inner conductor/insulating support assembly axially along the corrugated outer conductor without radial displacement. The transport device includes two movable contacts, such as skids or rollers, supported on a common pivot lever, the pivot lever being rotatably disposed about a pivot lever axis, which pivot lever axis is in turn disposed on the periphery of a support insulator or particle trap if one is used. The movable contacts are separated axially a distance equal to the axial distance between the peaks and valleys of the corrugations of the outer conductor and separated radially a distance equal to the radial distance between the peaks and valleys of the corrugations of the outer conductor. The transport device has the pivot lever axis disposed perpendicular to the direction of travel of the inner conductor/insulating support assembly.

Fischer, William H. (Pittsburgh, PA); Yoon, Kue H. (Pittsburgh, PA)

1984-04-10T23:59:59.000Z

112

Switchable heat pipe assembly  

SciTech Connect

The heat pipe assembly is formed into an H-shape or a Y-shape. The H-shaped configuration comprises two heat pipes, each having condenser and evaporator sections with wicking therein coupled by a tube with wick at their evaporator sections. The Y-shaped configuration utilizes a common evaporator section in place of the two evaporator sections of the H-shaped configuration. In both configurations, the connection between the vapor spaces of the two heat pipes equalizes vapor pressure within the heat pipes. Although both heat pipes have wicks, they have sufficient fluid only to saturate a single pipe. If heat is applied to the condenser section of one of the pipes, this heat pipe becomes inoperative since all the fluid is transferred to the second pipe which can operate with a lower thermal load.

Sun, T.H.; Basiulis, A.

1977-02-15T23:59:59.000Z

113

Insulated pipe clamp design  

SciTech Connect

Thin wall large diameter piping for breeder reactor plants can be subjected to significant thermal shocks during reactor scrams and other upset events. On the Fast Flux Test Facility, the addition of thick clamps directly on the piping was undesired because the differential metal temperatures between the pipe wall and the clamp could have significantly reduced the pipe thermal fatigue life cycle capabilities. Accordingly, an insulated pipe clamp design concept was developed. The design considerations and methods along with the development tests are presented. Special considerations to guard against adverse cracking of the insulation material, to maintain the clamp-pipe stiffness desired during a seismic event, to minimize clamp restraint on the pipe during normal pipe heatup, and to resist clamp rotation or spinning on the pipe are emphasized.

Anderson, M.J.; Hyde, L.L.; Wagner, S.E.; Severud, L.K.

1980-01-01T23:59:59.000Z

114

Parametric performance analysis of steam-injected gas turbine with a thermionic-energy-converter-lined combustor  

SciTech Connect

The performance of steam-injected gas turbines having combustors lined with thermionic energy converters (STIG/TEC systems) was analyzed and compared with that of two baseline systems a steam-injected gas turbine (without a TEC-lined combustor) and a conventional combined gas turbine/steam turbine cycle. Common gas turbine parameters were assumed for all of the systems. Two configurations of the STIG/TEC system were investigated. In both cases, steam produced in an exhaust-heat-recovery boiler cools the TEC collectors. It is then injected into the gas combustion stream and expanded through the gas turbine. The STIG/TEC system combines the advantage of gas turbine steam injection with the conversion of high-temperature combustion heat by TEC's. The addition of TEC's to the baseline steam-injected gas turbine improves both its efficiency and specific power. Depending on system configuration and design parameters, the STIG/TEC system can also achieve higher efficiency and specific power than the baseline combined cycle.

Choo, Y.K.; Burns, R.K.

1982-02-01T23:59:59.000Z

115

Heat pipe fabrication  

SciTech Connect

A heat pipe is disclosed which is fabricated with an artery arranged so that the warp and weave of the wire mesh are at about a 45/sup 0/ angle with respect to the axis of the heat pipe.

Leinoff, S.; Edelstein, F.; Combs, W.

1977-01-18T23:59:59.000Z

116

Common Types of Pipe  

Science Conference Proceedings (OSTI)

...Reseamed and drifted pipe is similar to casing, but is manufactured and inspected in a manner that assures the well driller that the pipe string will have a predetermined minimum diameter sufficient to permit unrestricted passage of pumps or

117

Power Line Fault Current Coupling to Nearby Natural Gas Pipelines, Volume 3: Analysis of Pipeline Coating Impedance  

Science Conference Proceedings (OSTI)

As regulatory agencies encourage construction of transmission lines and gas pipelines along shared utility corridors, the likelihood of voltage and current coupling increases. Development of equations that determine the electrical characteristics of pipeline coatings will help utility engineers to accurately predict induced voltages and currents.

1988-08-01T23:59:59.000Z

118

NMR line shapes of a gas of nuclear spin-1/2 molecules in fluctuating nano-containers  

E-Print Network (OSTI)

Reported in this paper is the impact of the fluctuations of the geometry of the nano-meter gas containers in the medium on the NMR line shape of the gas inside of the nano-containers. We calculate exactly the NMR line shape of the gas of spin-1/2 carrying molecules for two typical dynamics of the nano-container volume and the orientation with respect to the external magnetic field: (i) for a Gaussian stochastic dynamics, and (ii) for the regular harmonic vibrations. For the Gaussian ensemble of static disordered containers having an infinite correlation time, $\\tau_{\\sf c} \\to \\infty $, the overall line shape is shown to obey a logarithmic low frequency asymptotics, $ I(\\omega) = {const} \\times \\ln (\\frac{1}{\\omega})$, at $\\omega \\to 0$, and exponentially decaying asymptotics in a high frequency domain. For the Gaussian ensemble of the rapidly fluctuating containers of a finite $\\tau_{\\sf c}$, the overall line shape has a bell-shaped profile with $\\sim \\omega^{-4}$ far wing behaviour. In addition, we calculate exactly a satellite structure of the NMR line shape when the nano-bubbles in a liquid are affected by the harmonic deformations due to the acoustic waves.

E. B. Fel'dman; M. G. Rudavets

2004-09-13T23:59:59.000Z

119

MOLECULAR AND ATOMIC LINE SURVEYS OF GALAXIES. I. THE DENSE, STAR-FORMING GAS PHASE AS A BEACON  

Science Conference Proceedings (OSTI)

We predict the space density of molecular gas reservoirs in the universe and place a lower limit on the number counts of carbon monoxide (CO), hydrogen cyanide (HCN) molecular, and [C II] atomic emission lines in blind redshift surveys in the submillimeter-centimeter spectral regime. Our model uses (1) recently available HCN spectral line energy distributions (SLEDs) of local luminous infrared galaxies (LIRGs, L{sub IR} > 10{sup 11} L{sub Sun }), (2) a value for {epsilon}{sub *} = SFR/M{sub dense}(H{sub 2}) provided by new developments in the study of star formation feedback on the interstellar medium, and (3) a model for the evolution of the infrared luminosity density. Minimal 'emergent' CO SLEDs from the dense gas reservoirs expected in all star-forming systems in the universe are then computed from the HCN SLEDs since warm, HCN-bright gas will necessarily be CO-bright, with the dense star-forming gas phase setting an obvious minimum to the total molecular gas mass of any star-forming galaxy. We include [C II] as the most important of the far-infrared cooling lines. Optimal blind surveys with the Atacama Large Millimeter Array (ALMA) could potentially detect very distant (z {approx} 10-12) [C II] emitters in the {>=}ULIRG galaxy class at a rate of {approx}0.1-1 hr{sup -1} (although this prediction is strongly dependent on the star formation and enrichment history at this early epoch), whereas the (high-frequency) Square Kilometer Array will be capable of blindly detecting z > 3 low-J CO emitters at a rate of {approx}40-70 hr{sup -1}. The [C II] line holds special promise for detecting metal-poor systems with extensive reservoirs of CO-dark molecular gas where detection rates with ALMA can reach up to 2-7 hr{sup -1} in Bands 4-6.

Geach, James E. [Department of Physics, McGill University, 3600 rue University, Montreal, Quebec H3A 2T8 (Canada); Papadopoulos, Padelis P., E-mail: jimgeach@physics.mcgill.ca, E-mail: padelis@mpifr-bonn.mpg.de [Max Planck Institute for Radioastronomy, Auf dem Huegel 69, D-53121 Bonn (Germany)

2012-10-01T23:59:59.000Z

120

Reliability Estimation for Double Containment Piping  

Science Conference Proceedings (OSTI)

Double walled or double containment piping is considered for use in the ITER international project and other next-generation fusion device designs to provide an extra barrier for tritium gas and other radioactive materials. The extra barrier improves confinement of these materials and enhances safety of the facility. This paper describes some of the design challenges in designing double containment piping systems. There is also a brief review of a few operating experiences of double walled piping used with hazardous chemicals in different industries. This paper recommends approaches for the reliability analyst to use to quantify leakage from a double containment piping system in conceptual and more advanced designs. The paper also cites quantitative data that can be used to support such reliability analyses.

L. Cadwallader; T. Pinna

2012-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

New Northeast natural gas pipeline capacity comes on-line - Today ...  

U.S. Energy Information Administration (EIA)

natural gas; prices; states; production; crude oil; consumption; international; coal; generation; renewable; ... of capacity from Clarington, Ohio to York County ...

122

Dual manifold heat pipe evaporator  

DOE Patents (OSTI)

An improved evaporator section is described for a dual manifold heat pipe. Both the upper and lower manifolds can have surfaces exposed to the heat source which evaporate the working fluid. The tubes in the tube bank between the manifolds have openings in their lower extensions into the lower manifold to provide for the transport of evaporated working fluid from the lower manifold into the tubes and from there on into the upper manifold and on to the condenser portion of the heat pipe. A wick structure lining the inner walls of the evaporator tubes extends into both the upper and lower manifolds. At least some of the tubes also have overflow tubes contained within them to carry condensed working fluid from the upper manifold to pass to the lower without spilling down the inside walls of the tubes. 1 figure.

Adkins, D.R.; Rawlinson, K.S.

1994-01-04T23:59:59.000Z

123

Dual manifold heat pipe evaporator  

DOE Patents (OSTI)

An improved evaporator section for a dual manifold heat pipe. Both the upper and lower manifolds can have surfaces exposed to the heat source which evaporate the working fluid. The tubes in the tube bank between the manifolds have openings in their lower extensions into the lower manifold to provide for the transport of evaporated working fluid from the lower manifold into the tubes and from there on into the upper manifold and on to the condenser portion of the heat pipe. A wick structure lining the inner walls of the evaporator tubes extends into both the upper and lower manifolds. At least some of the tubes also have overflow tubes contained within them to carry condensed working fluid from the upper manifold to pass to the lower without spilling down the inside walls of the tubes.

Adkins, Douglas R. (Albuquerque, NM); Rawlinson, K. Scott (Albuquerque, NM)

1994-01-01T23:59:59.000Z

124

Semi-flexible gas-insulated transmission line using protection tube in conductor plug-in joint  

DOE Patents (OSTI)

A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. A plug and socket arrangement is utilized for joining adjacent sections of the inner conductor, and a protection tube is utilized inside the hollow plug to maintain proper alignment of the joint when the transmission line is bent. 3 figs.

Kommineni, P.R.

1983-01-25T23:59:59.000Z

125

Semi-flexible gas-insulated transmission line using protection tube in conductor plug-in joint  

DOE Patents (OSTI)

A gas-insulated transmission line includes an outer sheath, an inner conductor, an insulating gas electrically insulating the inner conductor from the outer sheath, and insulating supports insulatably supporting the inner conductor within the outer sheath. The inner conductor is provided with flexibility by main conductor sections which are joined together through a conductor hub section and flexible flexing elements. Stress shields are provided to control the electric field at the locations of the conductor hub sections where the insulating supports are contacting the inner conductor. A plug and socket arrangement is utilized for joining adjacent sections of the inner conductor, and a protection tube is utilized inside the hollow plug to maintain proper alignment of the joint when the transmission line is bent.

Kommineni, Prasad R. (Westboro, MA)

1983-01-25T23:59:59.000Z

126

Particle trap to sheath non-binding contact for a gas-insulated transmission line having a corrugated outer conductor  

DOE Patents (OSTI)

A non-binding particle trap to outer sheath contact for use in gas insulated transmission lines having a corrugated outer conductor. The non-binding feature of the contact according to the teachings of the invention is accomplished by having a lever arm rotatably attached to a particle trap by a pivot support axis disposed parallel to the direction of travel of the inner conductor/insulator/particle trap assembly.

Fischer, William H. (Pittsburgh, PA)

1984-04-24T23:59:59.000Z

127

Abrasion resistant heat pipe  

DOE Patents (OSTI)

A specially constructed heat pipe is described for use in fluidized bed combustors. Two distinct coatings are spray coated onto a heat pipe casing constructed of low thermal expansion metal, each coating serving a different purpose. The first coating forms aluminum oxide to prevent hydrogen permeation into the heat pipe casing, and the second coating contains stabilized zirconium oxide to provide abrasion resistance while not substantially affecting the heat transfer characteristics of the system.

Ernst, D.M.

1984-10-23T23:59:59.000Z

128

Abrasion resistant heat pipe  

DOE Patents (OSTI)

A specially constructed heat pipe for use in fluidized bed combustors. Two distinct coatings are spray coated onto a heat pipe casing constructed of low thermal expansion metal, each coating serving a different purpose. The first coating forms aluminum oxide to prevent hydrogen permeation into the heat pipe casing, and the second coating contains stabilized zirconium oxide to provide abrasion resistance while not substantially affecting the heat transfer characteristics of the system.

Ernst, Donald M. (Leola, PA)

1984-10-23T23:59:59.000Z

129

Oil and Gas Flow Data from the Top Hat and from the Choke Line...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Water Reactor Sustainability Program: Milestone Report on Materials and Machining of Specimens for the ATR-2 Experiment Natural Gas Imports and Exports - Second Quarter Report 2013...

130

Internal pipe attachment mechanism  

DOE Patents (OSTI)

An attachment mechanism is described for repairing or extending fluid carrying pipes, casings, conduits, etc. utilizing one-way motion of spring tempered fingers to provide a mechanical connection between the attachment mechanism and the pipe. The spring tempered fingers flex to permit insertion into a pipe to a desired insertion depth. The mechanical connection is accomplished by reversing the insertion motion and the mechanical leverage in the fingers forces them outwardly against the inner wall of the pipe. A seal is generated by crushing a sealing assembly by the action of setting the mechanical connection. 6 figures.

Bast, R.M.; Chesnut, D.A.; Henning, C.D.; Lennon, J.P.; Pastrnak, J.W.; Smith, J.A.

1994-12-13T23:59:59.000Z

131

Simple Models of Metal-Line Absorption and Emission from Cool Gas Outflows  

E-Print Network (OSTI)

Because the FeII lines are connected by optically-thin transitions to fine-structure levels, their profiles more closely reproduce the intrinsic opacity of the wind. Together these results naturally explain the absorption and emission-line characteristics observed for star-forming galaxies at zabsorption-line profiles, the surface brightness profiles offer a unique means of assessing the morphology and size of galactic-scale winds. Furthermore, the kinematics and line-ratios offer powerful diagnostics of outflows, motivating deep, spatially-extended spectroscopic observations.

Prochaska, J Xavier; Rubin, Kate

2011-01-01T23:59:59.000Z

132

Interfacial Mixing in Viscous Pipe Flows Interim report to Imperial Oil  

E-Print Network (OSTI)

. Introduction The cost of energy to pump oil through a pipe line is greatly reduced if the ow is not turbulent in this area, in part, because oil companies have only recently considered pumping oil through pipesInterfacial Mixing in Viscous Pipe Flows Interim report to Imperial Oil D. Van Vliet and B. R

Sutherland, Bruce

133

Hot Leg Piping Materials Issues  

SciTech Connect

With Naval Reactors (NR) approval of the Naval Reactors Prime Contractor Team (NRPCT) recommendation to develop a gas cooled reactor directly coupled to a Brayton power conversion system as the space nuclear power plant (SNPP) for Project Prometheus (References a and b) the reactor outlet piping was recognized to require a design that utilizes internal insulation (Reference c). The initial pipe design suggested ceramic fiber blanket as the insulation material based on requirements associated with service temperature capability within the expected range, very low thermal conductivity, and low density. Nevertheless, it was not considered to be well suited for internal insulation use because its very high surface area and proclivity for holding adsorbed gases, especially water, would make outgassing a source of contaminant gases in the He-Xe working fluid. Additionally, ceramic fiber blanket insulating materials become very friable after relatively short service periods at working temperatures and small pieces of fiber could be dislodged and contaminate the system. Consequently, alternative insulation materials were sought that would have comparable thermal properties and density but superior structural integrity and greatly reduced outgassing. This letter provides technical information regarding insulation and materials issues for the Hot Leg Piping preconceptual design developed for the Project Prometheus space nuclear power plant (SNPP).

V. Munne

2006-07-19T23:59:59.000Z

134

Heat pipe technology issues  

SciTech Connect

Critical high temperature, high power applications in space nuclear power designs are near the current state of the art of heat pipe technology in terms of power density, operating temperature, and lifetime. Recent heat pipe development work at Los Alamos National Laboratory has involved performance testing of typical space reactor heat pipe designs to power levels in excess of 19 kW/cm/sup 2/ axially and 300 W/cm/sup 2/ radially at temperatures in the 1400 to 1500 K range. Operation at conditions in the 10 kW/cm/sup 2/ range has been sustained for periods of up to 1000 hours without evidence of performance degradation. The effective length for heat transport in these heat pipes was from 1.0 to 1.5 M. Materials used were molybdenum alloys with lithium employed as the heat pipe operating fluid. Shorter, somewhat lower power, molybdenum heat pipes have been life tested at Los Alamos for periods of greater than 25,000 hours at 1700 K with lithium and 20,000 hours at 1500/sup 0/K with sodium. These life test demonstrations and the attendant performance limit investigations provide an experimental basis for heat pipe application in space reactor design and represent the current state-of-the-art of high temperature heat pipe technology.

Merrigan, M.A.

1984-04-01T23:59:59.000Z

135

Heat pipe heat amplifier  

SciTech Connect

In a heat pipe combination consisting of a common condenser section with evaporator sections at either end, two working fluids of different vapor pressures are employed to effectively form two heat pipe sections within the same cavity to support an amplifier mode of operation.

Arcella, F.G.

1978-08-15T23:59:59.000Z

136

Heat pipe system  

SciTech Connect

A heat pipe diode device for transferring heat from a heat source component to a heat sink wall is described. It contains a heat pipe body member attached to the best source; the heat source having a wall forming at least a portion of the normal evaporator section of the heat pipe diode; a working fluid within the body member; a cover for the heat pipe diode forming at least a portion of the heat sink wall; the cover forming the normal condenser for the heat pipe diode; a wick connected between the condenser and the evaporator of the heat pipe diode; means for retaining the wick adjacent the heat pipe wall; a wick support plate adjacent to the cover; the wick being attached to the support plate; means for holding the wick in contact with the cover; and means, responsive to excessive temperatures at the heat sink wall, for moving the support plate and a portion of the wick away from the cover to thereby substantially reduce heat flow in the reverse direction through said heat pipe diode device.

Kroebig, H.L.; Riha, F.J. III

1974-12-03T23:59:59.000Z

137

Unstable heat pipes  

DOE Green Energy (OSTI)

Heat pipes are an important feature of models of vapor-dominated geothermal reservoirs. Numerical experiments reveal that a vapor-dominated heat pipe is unstable if pressure is controlled at shallow levels. This instability is discussed in physical terms, and some implications for geothermal reservoirs are considered. 9 refs., 10 figs.

McGuinness, M.J.; Pruess, K.

1987-10-01T23:59:59.000Z

138

Heat pipe development status  

SciTech Connect

Test heat pipes have been operated in the 1400 K to 1700 K range for periods in excess of 20,000 hours with the objective of understanding and controlling corrosion and failure mechanisms. The results of a post test analysis of one of these heat pipes that was operated for 25,216 hours at 1700 K are reviewed and the implications for heat pipe lifetime discussed. An in-process report of an investigation of transient heat pipe behavior is presented. This investigation is being conducted as a result of restart problems encountered during life test of a 2 m. radiation cooled heat pipe. The results of a series of shut-down tests from power and temperature are given and probable causes of the restart problem discussed.

Merrigan, M.A.

1984-01-01T23:59:59.000Z

139

Extendable pipe crawler  

DOE Patents (OSTI)

A pipe crawler is described having a front leg assembly and a back leg assembly connected together by two air cylinders, each leg assembly having four extendable legs and a pair of actuators for sliding the extendable legs radially outward to increase the range of the legs when the pipe crawler enters a section of a pipe having a larger diameter. The crawler crawls by inchworm'-like motion, the front leg assembly and back leg assembly alternately engaging and disengaging the wall of the pipe to hold the pipe crawler as the air cylinders alternately advance the front leg assembly and bring up the rear leg assembly. The pair of actuators of each leg assembly are parallel, adjacent and opposing acting so that each slides two adjacent extendable legs radially outward. 5 figures.

Hapstack, M.

1991-05-28T23:59:59.000Z

140

Extendable pipe crawler  

DOE Patents (OSTI)

A pipe crawler having a front leg assembly and a back leg assembly connected together by two air cylinders, each leg assembly having four extendable legs and a pair of actuators for sliding the extendable legs radically outward to increase the range of the legs when the pipe crawler enters a section of pipe having a larger diameter. The crawler crawls by inchworm''-like motion, the front leg assembly and back leg assembly alternately engaging and disengaging the wall of the pipe to hold the pipe crawler as the air cylinders alternately advance the front leg assembly and bring up the rear leg assembly. The pair of actuators of each leg assembly are parallel, adjacent and opposing acting so that each slides two adjacent extendable legs radially outward. 5 figs.

Hapstack, M.

1990-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Analysis and Optimization of the Power Cycle Based on the Cold Energy of Liquefied Natural Gas  

Science Conference Proceedings (OSTI)

Liquid natural gas (LNG) delivered by sea-ships contains considerable cryogenic energy which can be used for power generation before its evaporation and introduction into the system of pipe line. Electric power generation utilizing LNG cold energy is ... Keywords: liquefied natural gast, cold energy recovery, pinch analysis, exergy, optimization

Lu Yuanwei; Yang Hongchang; Ma Chongfang

2011-01-01T23:59:59.000Z

142

No loss single line fueling station for liquid natural gas vehicles  

Science Conference Proceedings (OSTI)

A no loss fueling station is described for delivery of liquid natural gas (LNG) to a fuel tank of a use device such as a motor vehicle, comprising: (a) a pressure building tank holding a quantity of LNG and a natural gas head; (b) first means for selectively building the pressure and temperature in the pressure building tank; (c) second means for selectively reducing the pressure and temperature in the pressure building tank; (d) means for controlling the first and second means to maintain a desired pressure and temperature in the pressure building tank without venting natural gas to the atmosphere; and (e) means for delivering LNG from the pressure building tank to the use device.

Cieslukowski, R.E.

1993-08-03T23:59:59.000Z

143

Piping stress handbook. Second edition  

Science Conference Proceedings (OSTI)

This abridged volume contains the following: Coefficients of thermal expansion. Allowable stress range for ANSI/ASME Power Piping Code B31.1. Stress intensification and flexibility factors. Pressure and stress ratios. Design criteria for allowable loads, moment, and stresses. Properties of pipe. Weight and dimensions of pipe and components. Pipe support selection and design. Fundamentals of expansion joints. Index.

Helguero, V.

1986-01-01T23:59:59.000Z

144

Flexible ultrasonic pipe inspection apparatus  

DOE Patents (OSTI)

Pipe crawlers, pipe inspection {open_quotes}rabbits{close_quotes} and similar vehicles are widely used for inspecting the interior surfaces of piping systems, storage tanks and process vessels for damaged or flawed structural features. This paper describes the design of a flexible, modular ultrasonic pipe inspection apparatus.

Jenkins, C.F.; Howard, B.D.

1994-01-01T23:59:59.000Z

145

Neutron imaging of alkali metal heat pipes  

Science Conference Proceedings (OSTI)

High-temperature heat pipes are two-phase, capillary driven heat transfer devices capable of passively providing high thermal fluxes. Such a device using a liquid-metal coolant can be used as a solution for successful thermal management on hypersonic flight vehicles. Imaging of the liquid-metal coolant inside will provide valuable information in characterizing the detailed heat and mass transport. Neutron imaging possesses an inherent advantage from the fact that neutrons penetrate the heat pipe metal walls with very little attenuation, but are significantly attenuated by the liquid metal contained inside. Using the BT-2 beam line at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland, preliminary efforts have been conducted on a nickel-sodium heat pipe. The contrast between the attenuated beam and the background is calculated to be approximately 3%. This low contrast requires sacrifice in spatial or temporal resolution so efforts have since been concentrated on lithium (Li) which has a substantially larger neutron attenuation cross section. Using the CG-1D beam line at the High Flux Isotope Reactor (HFIR) of Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee, the first neutron images of high-temperature molybdenum (Mo)-Li heat pipes have been achieved. The relatively high neutron cross section of Li allows for the visualization of the Li working fluid inside the heat pipes. The evaporator region of a gravity assisted cylindrical heat pipe prototype 25 cm long was imaged from start-up to steady state operation up to approximately 900 C. In each corner of the square bore inside, the capillary action raises the Li meniscus above the bulk Li pool in the evaporator region. As the operational temperature changes, the meniscus shapes and the bulk meniscus height also changes. Furthermore, a three-dimensional tomographic image is also reconstructed from the total of 128 projection images taken 1.4o apart in which the Li had already cooled and solidified.

Kihm, Ken [University of Tennessee, Knoxville (UTK); Kirchoff, Eric [University of Tennessee, Knoxville (UTK); Golden, Matt [University of Tennessee, Knoxville (UTK); Rosenfeld, J. [Thermacore Inc.; Rawal, S. [Lockheed Martin Space Systems Company; Pratt, D. [United States Air Force Research Laboratory, Wright-Patterson Air Force Base; Bilheux, Hassina Z [ORNL; Walker, Lakeisha MH [ORNL; Voisin, Sophie [ORNL; Hussey, Dan [NIST Center for Neutron Research (NCRN), Gaithersburg, MD

2013-01-01T23:59:59.000Z

146

Service Water Piping Guideline  

Science Conference Proceedings (OSTI)

In the years 1988 and 1989, EPRI organized the Service Water Working Group (SWWG) to identify and help resolve the many issues surrounding service water (SW) systems in nuclear power plants. One issue identified by the SWWG was corrosion in service water piping systems. Interest in this issue resulted in the development of several technical reports: Guidelines for the Repair/Replacement Welding of Nuclear Service Water Systems, TR-100386; Guide for the Examination of Service Water System Piping, TR-10206...

2005-09-30T23:59:59.000Z

147

Freezable heat pipe  

SciTech Connect

A heat pipe whose fluid can be repeatedly frozen and thawed without damage to the casing. An additional part is added to a conventional heat pipe. This addition is a simple porous structure, such as a cylinder, self-supporting and free standing, which is dimensioned with its diameter not spanning the inside transverse dimension of the casing, and with its length surpassing the depth of maximum liquid.

Ernst, Donald M. (Leola, PA); Sanzi, James L. (Lancaster, PA)

1981-02-03T23:59:59.000Z

148

SEALING LARGE-DIAMETER CAST-IRON PIPE JOINTS UNDER LIVE CONDITIONS  

Science Conference Proceedings (OSTI)

Utilities in the U.S. operate over 75,000 km (47,000 miles) of old cast-iron pipes for gas distribution. The bell-and-spigot joints that connect pipe sections together tend to leak as these pipes age. Current repair practices are costly and highly disruptive. The objective of this program is to design, test and commercialize a robotic system capable of sealing multiple castiron bell and spigot joints from a single pipe entry point. The proposed system will perform repairs while the pipe remains in service by traveling through the pipe, cleaning each joint surface, and installing a stainless-steel sleeve lined with an epoxy-impregnated felt across the joint. This approach will save considerable time and labor, avoid traffic disruption, and eliminate any requirement to interrupt service to customers (which would result in enormous expense to utilities). Technical challenges include: (1) repair sleeves must compensate for diametric variation and eccentricity of cast-iron pipes; (2) the assembly must travel long distances through pipes containing debris; (3) the pipe wall must be effectively cleaned in the immediate area of the joint to assure good bonding of the sleeve; and (4) an innovative bolt-on entry fitting is required to conduct repair operations on live mains. The development effort is divided into eleven tasks. Task 1 (Program Management) and Task 2 (Establishment of Detailed Design Specifications) were completed in prior quarters while Task 3 (Design and Fabricate Ratcheting Stainless-Steel Repair Sleeves) has progressed to installing prototype sleeves in cast iron test pipe segments. Efforts in this quarter continued to focus on Tasks 4-8, with significant progress made in each as well as field testing of the 4-inch gas pipe repair robot in cast iron pipe at Public Service Electric & Gas. The field tests were conducted August 23-26, 2004 in Oradell, New Jersey. The field tests identified several design issues which need to be implemented in both the small- and large-diameter cast iron repair robots to assure their commercial success. Task 4 (Design, Fabricate and Test Patch Setting Robotic Train) progressed to the design of the control electronics and pneumatic system to inflate the bladder robotic patch setting module in the last quarter 5. In this quarter, work has been concentrated on increasing the nitrogen bladder reservoir volume to allow at least two complete patch inflation/patch setting cycles in the event the sleeve does not set all ratchets in the same row on the first attempt. This problem was observed on a few of the repair sleeves that were recently installed during field tests with the small-diameter robotic system. For Task 5 (Design & Fabricate Pipe-Wall Cleaning Robot Train with Pan/Zoom/Tilt Camera) it was observed that it will be necessary to add a stiff brush to push debris away from the immediate vicinity of the bell and spigot joints in mains having low gas velocities. Otherwise, material removed by the cleaning flails (which were found to be very effective in cleaning bell and spigot joints) simply falls to the low side of the pipe and accumulates in a pile. This accumulation can prevent the sleeve from achieving a leak free repair. Similarly, it is also necessary to design a small magnet to capture existing service tap coupons and allow their removal from the inside of the pipe. These coupons were found to cause difficulty in launching and retrieving the small pipe repair robot; one coupon lodged beneath the end of the guide shoe. These new features require redesign of the pipe wall cleaning train and modification to the patch setting train. Task 6 (Design & Build Surface Control and Monitoring System) was previously completed with the control and computer display functions being operated through LabView. However, this must now be re-visited to add control routines for the coupon catcher to be added. This will most likely include a lift-off/place-on magnet translation function. Task 7 (Design & Fabricate Large Diameter Live Access System) progressed to completing the detailed design of th

Kiran M. Kothari; Gerard T. Pittard

2004-11-01T23:59:59.000Z

149

On-line gas chromatographic studies of rutherfordium (Element 104), hahnium (Element 105), and homologs  

Science Conference Proceedings (OSTI)

Gas-phase isothermal chromatogaphy is a method by which volatile compounds of different chemical elements can be separated according to their volatilities. The technique, coupled with theoretical modeling of the processes occurring in the chromatogaphy column, provides accurate determination of thermodynamic properties (e.g., adsorption enthalpies) for compounds of elements, such as the transactinides, which can only be produced on an atom-at-a-time basis. In addition, the chemical selectivity of the isothermal chromatogaphy technique provides the decontamination from interfering activities necessary for the determination of the nuclear decay properties of isotopes of the transactinide elements. Volatility measurements were performed on chloride species of Rf and its group 4 homologs, Zr and Hf, as well as Ha and its group 5 homologs, Nb and Ta. Adsorption enthalpies were calculated for all species using a Monte Carlo code simulation based on a microscopic model for gas thermochromatography in open columns with laminar flow of the carrier gas. Preliminary results are presented for Zr- and Nb-bromides.

Kadkhodayan, B.

1993-05-01T23:59:59.000Z

150

PC-based fluid and heat transfer analyzer for two-phase flow in pipes.  

E-Print Network (OSTI)

??Modeling the simultaneous flow of gas and liquid or two-phase gas-liquid flow in pipes is a key aspect in petroleum production. These models can enhance… (more)

Afonja, Gbolahan.

2006-01-01T23:59:59.000Z

151

Electrical transmission line diametrical retainer  

DOE Patents (OSTI)

The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within down hole components. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to with stand the tension and compression of drill pipe during routine drilling cycles.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David (Lehi, UT); Dahlgren, Scott (Provo, UT); Sneddon, Cameron (Provo, UT); Briscoe, Michael (Lehi, UT); Fox, Joe (Spanish Fork, UT)

2004-12-14T23:59:59.000Z

152

Heat Pipe Integrated Microsystems  

SciTech Connect

The trend in commercial electronics packaging to deliver ever smaller component packaging has enabled the development of new highly integrated modules meeting the demands of the next generation nano satellites. At under ten kilograms, these nano satellites will require both a greater density electronics and a melding of satellite structure and function. Better techniques must be developed to remove the subsequent heat generated by the active components required to-meet future computing requirements. Integration of commercially available electronics must be achieved without the increased costs normally associated with current generation multi chip modules. In this paper we present a method of component integration that uses silicon heat pipe technology and advanced flexible laminate circuit board technology to achieve thermal control and satellite structure. The' electronics/heat pipe stack then becomes an integral component of the spacecraft structure. Thermal management on satellites has always been a problem. The shrinking size of electronics and voltage requirements and the accompanying reduction in power dissipation has helped the situation somewhat. Nevertheless, the demands for increased onboard processing power have resulted in an ever increasing power density within the satellite body. With the introduction of nano satellites, small satellites under ten kilograms and under 1000 cubic inches, the area available on which to place hot components for proper heat dissipation has dwindled dramatically. The resulting satellite has become nearly a solid mass of electronics with nowhere to dissipate heat to space. The silicon heat pipe is attached to an aluminum frame using a thermally conductive epoxy or solder preform. The frame serves three purposes. First, the aluminum frame provides a heat conduction path from the edge of the heat pipe to radiators on the surface of the satellite. Secondly, it serves as an attachment point for extended structures attached to the satellite such as solar panels, radiators, antenna and.telescopes (for communications or sensors). Finally, the packages make thermal contact to the surface of the silicon heat pipe through soft thermal pads. Electronic components can be placed on both sides of the flexible circuit interconnect. Silicon heat pipes have a number of advantages over heat pipe constructed from other materials. Silicon heat pipes offer the ability to put the heat pipe structure beneath the active components of a processed silicon wafer. This would be one way of efficiently cooling the heat generated by wafer scale integrated systems. Using this technique, all the functions of a satellite could be reduced to a few silicon wafers. The integration of the heat pipe and the electronics would further reduce the size and weight of the satellite.

Gass, K.; Robertson, P.J.; Shul, R.; Tigges, C.

1999-03-30T23:59:59.000Z

153

Development of an Acoustic Sensor On-Line Gas Temperature Measurement in Gasifiers  

Science Conference Proceedings (OSTI)

This project was awarded under U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) Program Solicitation DE-PS26-02NT41422 and specifically addresses Technical Topical Area 2 - Gasification Technologies. The project team includes Enertechnix, Inc. as the main contractor and ConocoPhillips Company as a technical partner, who also provides access to the SG Solutions Gasification Facility (formerly Wabash River Energy Limited), host for the field-testing portion of the research. The objective of this project was to adapt acoustic pyrometer technology to make it suitable for measuring gas temperature inside a coal gasifier, to develop a prototype sensor based on this technology, and to demonstrate its performance through testing on a commercial gasifier. The project was organized in three phases, each of approximately one year duration. The first phase consisted of researching a variety of sound generation and coupling approaches suitable for use with a high pressure process, evaluation of the impact of gas composition variability on the acoustic temperature measurement approach, evaluation of the impact of suspended particles and gas properties on sound attenuation, evaluation of slagging issues and development of concepts to deal with this issue, development and testing of key prototype components to allow selection of the best approaches, and development of a conceptual design for a field prototype sensor that could be tested on an operating gasifier. The second phase consisted of designing and fabricating a series of prototype sensors, testing them in the laboratory, and developing a conceptual design for a field prototype sensor. The third phase consisted of designing and fabricating the field prototype, and testing it in the lab and in a commercial gasifier to demonstrate the ability to obtain accurate measurements of gas temperature in an operating gasifier. Following the completion of the initial 3 year project, several continuations were awarded by the Department of Energy to allow Enertechnix to conduct extended testing of the sensor at the Wabash River facility. In February, 2008 the sensor was installed on the gasifier in preparation for a long-term test. During the initial testing of the sensor a stainless steel tube on the sensor failed and allowed syngas to escape. The syngas self-ignited and the ensuing small fire damaged some of the components on the sensor. There was no damage to the gasifier or other equipment and no injuries resulted from this incident. Two meetings were held to identify the root causes of the incident-one at Wabash River and one at Enertechnix. A list of recommended improvements that would have addressed the causes of the incident was created and presented to the Department of Energy on May 2, 2008. However, the DOE decided not to pursue these improvements and terminated the project. This report describes all of the activities conducted during the project and reports the findings of each activity in detail. The investigation of potential sound generation and coupling methods led to the selection of a reflected shock method which has been developed into a functioning prototype device. The principles of operation of this device and its performance characteristics are described in the report. Modeling of the attenuation of sound by suspended particles and by interaction of the sound pulses with the high temperature syngas inside the gasifier was conducted and the predictions of those models were used to determine the required sound pulse intensity to allow the sound pulses to be detected after passage through the gasifier environment. These modeling results are presented in this report. A study of the likely spatial and temporal variability of gas composition inside the gasifier was performed and the results of that study was used to predict the impact of that variability on the accuracy of the acoustic temperature method. These results are reported here. A design for a port rodding mechanism was developed to deal with potential slagging issues and was incorporated i

Peter Ariessohn

2008-06-30T23:59:59.000Z

154

Development Of An Acoustice Sensor For On-Line Gas Temperature Measurement In Gasifiers  

Science Conference Proceedings (OSTI)

This project was awarded under U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) Program Solicitation DE-PS26-02NT41422 and specifically addresses Technical Topical Area 2 - Gasification Technologies. The project team includes Enertechnix, Inc. as the main contractor and ConocoPhillips Company as a technical partner, who also provides access to the SG Solutions Gasification Facility (formerly Wabash River Energy Limited), host for the field-testing portion of the research. The objective of this project was to adapt acoustic pyrometer technology to make it suitable for measuring gas temperature inside a coal gasifier, to develop a prototype sensor based on this technology, and to demonstrate its performance through testing on a commercial gasifier. The project was organized in three phases, each of approximately one year duration. The first phase consisted of researching a variety of sound generation and coupling approaches suitable for use with a high pressure process, evaluation of the impact of gas composition variability on the acoustic temperature measurement approach, evaluation of the impact of suspended particles and gas properties on sound attenuation, evaluation of slagging issues and development of concepts to deal with this issue, development and testing of key prototype components to allow selection of the best approaches, and development of a conceptual design for a field prototype sensor that could be tested on an operating gasifier. The second phase consisted of designing and fabricating a series of prototype sensors, testing them in the laboratory, and developing a conceptual design for a field prototype sensor. The third phase consisted of designing and fabricating the field prototype, and testing it in the lab and in a commercial gasifier to demonstrate the ability to obtain accurate measurements of gas temperature in an operating gasifier. This report describes all of the activities conducted during the project and reports the findings of each activity in detail. The investigation of potential sound generation and coupling methods led to the selection of a reflected shock method which has been developed into a functioning prototype device. The principles of operation of this device and its performance characteristics are described in the report. Modeling of the attenuation of sound by suspended particles and by interaction of the sound pulses with the high temperature syngas inside the gasifier was conducted and the predictions of those models were used to determine the required sound pulse intensity to allow the sound pulses to be detected after passage through the gasifier environment. These modeling results are presented in this report. A study of the likely spatial and temporal variability of gas composition inside the gasifier was performed and the results of that study was used to predict the impact of that variability on the accuracy of the acoustic temperature method. These results are reported here. A design for a port rodding mechanism was developed to deal with potential slagging issues and was incorporated into the prototype sensor. This port rodding mechanism operated flawlessly during the field testing, but because these tests were performed in a region of the gasifier that experiences little slagging, the effectiveness of the rodding mechanism in dealing with highly slagging conditions was not fully demonstrated. This report describes the design and operation of the automated Gasifier Acoustic Pyrometer (autoGAP) which was tested at the Wabash River facility. The results of the tests are reported and analyzed in detail. All of the objectives of the project have been achieved. A field prototype acoustic pyrometer sensor has been successfully tested at the Wabash River gasifier plant. Acoustic signals were propagated through the gases inside the gasifier and were detected by the receiver unit, the times of flight of these sound pulses were measured and these propagation times were converted into temperatures which agreed very well with thermocouple measurements m

Peter Ariessohn; Hans Hornung

2006-10-01T23:59:59.000Z

155

Absorption-Line Spectroscopy of Planetary Nebulae with FUSE: Probing the Molecular, Atomic, and Ionized Gas  

E-Print Network (OSTI)

The central stars of planetary nebulae (PNe) are natural targets for FUSE due to their UV brightness. The FUSE spectra of many PNe show absorption features due to circumstellar material in species ranging from H_2 and neutrals in the photodissociation region (PDR) to ions resident in the H II region. We report results from a program designed to search for nebular components in the H_2 Lyman and Werner resonance lines that are responsible for the fluorescent excitation of H_2 in strong FUV radiation fields. Our failure to detect H_2 in absorption in several PNe with strong near-infrared H_2 emission indicates that the molecular material has an asymmetrical or clumpy distribution. We also detect enrichments in the s-process product Ge, find that Fe is not depleted into dust along at least one line of sight through a PN, and show that starlight fluorescence can affect the populations of the excited fine-structure levels of O I.

Dinerstein, H L; Bowers, C W; Dinerstein, Harriet L.; Bowers, Charles W.

2004-01-01T23:59:59.000Z

156

Absorption-Line Spectroscopy of Planetary Nebulae with FUSE: Probing the Molecular, Atomic, and Ionized Gas  

E-Print Network (OSTI)

The central stars of planetary nebulae (PNe) are natural targets for FUSE due to their UV brightness. The FUSE spectra of many PNe show absorption features due to circumstellar material in species ranging from H_2 and neutrals in the photodissociation region (PDR) to ions resident in the H II region. We report results from a program designed to search for nebular components in the H_2 Lyman and Werner resonance lines that are responsible for the fluorescent excitation of H_2 in strong FUV radiation fields. Our failure to detect H_2 in absorption in several PNe with strong near-infrared H_2 emission indicates that the molecular material has an asymmetrical or clumpy distribution. We also detect enrichments in the s-process product Ge, find that Fe is not depleted into dust along at least one line of sight through a PN, and show that starlight fluorescence can affect the populations of the excited fine-structure levels of O I.

Harriet L. Dinerstein; N. C. Sterling; Charles W. Bowers

2004-10-25T23:59:59.000Z

157

Gas-recovery system  

DOE Patents (OSTI)

Nuclear explosions have been proposed as a means for recovering gas from underground gas-bearing rock formations. In present practice, the nuclear device is positioned at the end of a long pipe which is subsequently filled with grout or concrete. After the device is exploded, the grout is drilled through to provide a flow path for the released gas to the ground surface. As settled grout is brittle, often the compressive shock of the explosion fractures the grout and deforms the pipe so that it may not be removed nor reused. In addition, the pipe is sometimes pinched off completely and the gas flow is totally obstructed. (2 claims)

Heckman, R.A.

1971-12-14T23:59:59.000Z

158

Heat pipe technology for coal-fired power systems  

SciTech Connect

This report summarizes the results of heat pipe R and D activities at Argonne National Laboratory (ANL) during the 1977 to 1984 time period. The heat pipe development efforts were associated with a variety of DOE supported projects involving coal-fired prime movers for stationary power generation. The role of heat pipes for these power systems is in their potential application as thermal transport systems for integrating fluidized bed combustors (FBC) with prime movers ranging from Stirling engines in total energy systems (approx.10 MWe) to closed-cycle gas turbines in central power plants (approx.1000 MWe). The results of initial investigations at ANL demonstrated that high-temperature sodium heat pipes provided the best heat exchanger technology for integrating Stirling engines with coal-fired FBC systems. A major accomplishment included the development and validation of a computer code (ANL/HTP) which calculates heat pipe operating limits and other significant characteristics necessary for power plant design. A number of developmental and prototype heat pipes were designed and fabricated through a subcontract effort with Thermacore, Inc., and delivered to ANL for performance testing. Preliminary test results from ANL's Heat Pipe Test Facility, using induction heating and a gas-water calorimeter to establish energy balances, are given in the report. Test data obtained to date are consistent with ANL/HTP code predictions. 47 refs., 53 figs., 22 tabs.

Uherka, K.L.; Holtz, R.E.; McLennan, G.A.; Koehl, E.R.

1985-04-01T23:59:59.000Z

159

Fast reactor power plant design having heat pipe heat exchanger  

DOE Patents (OSTI)

The invention relates to a pool-type fission reactor power plant design having a reactor vessel containing a primary coolant (such as liquid sodium), and a steam expansion device powered by a pressurized water/steam coolant system. Heat pipe means are disposed between the primary and water coolants to complete the heat transfer therebetween. The heat pipes are vertically oriented, penetrating the reactor deck and being directly submerged in the primary coolant. A U-tube or line passes through each heat pipe, extended over most of the length of the heat pipe and having its walls spaced from but closely proximate to and generally facing the surrounding walls of the heat pipe. The water/steam coolant loop includes each U-tube and the steam expansion device. A heat transfer medium (such as mercury) fills each of the heat pipes. The thermal energy from the primary coolant is transferred to the water coolant by isothermal evaporation-condensation of the heat transfer medium between the heat pipe and U-tube walls, the heat transfer medium moving within the heat pipe primarily transversely between these walls.

Huebotter, P.R.; McLennan, G.A.

1984-08-30T23:59:59.000Z

160

Fast reactor power plant design having heat pipe heat exchanger  

DOE Patents (OSTI)

The invention relates to a pool-type fission reactor power plant design having a reactor vessel containing a primary coolant (such as liquid sodium), and a steam expansion device powered by a pressurized water/steam coolant system. Heat pipe means are disposed between the primary and water coolants to complete the heat transfer therebetween. The heat pipes are vertically oriented, penetrating the reactor deck and being directly submerged in the primary coolant. A U-tube or line passes through each heat pipe, extended over most of the length of the heat pipe and having its walls spaced from but closely proximate to and generally facing the surrounding walls of the heat pipe. The water/steam coolant loop includes each U-tube and the steam expansion device. A heat transfer medium (such as mercury) fills each of the heat pipes. The thermal energy from the primary coolant is transferred to the water coolant by isothermal evaporation-condensation of the heat transfer medium between the heat pipe and U-tube walls, the heat transfer medium moving within the heat pipe primarily transversely between these walls.

Huebotter, Paul R. (Western Springs, IL); McLennan, George A. (Downers Grove, IL)

1985-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

3 , LNG (Liquefied Natural Gas) -165oC  

E-Print Network (OSTI)

C / . Natural Gas Hydrate (NGH) Liquefied Natural Gas (LNG) Modes of Transport and Storage , , . . . , . , LNG (Liquefied Natural Gas) -165oC , . (Piped Natural Gas, PNG) , , . PNG, LNG ( 2-3 ), . (Natural Gas Hydrate, NGH) / . -20o

Hong, Deog Ki

162

Apparatus for moving a pipe inspection probe through piping  

DOE Patents (OSTI)

A method and apparatus are disclosed for controllably moving devices for cleaning or inspection through piping systems, including piping systems with numerous piping bends therein, by using hydrostatic pressure of a working fluid introduced into the piping system. The apparatus comprises a reservoir or other source for supplying the working fluid to the piping system, a launch tube for admitting the device into the launcher and a reversible, positive displacement pump for controlling the direction and flow rate of the working fluid. The device introduced into the piping system moves with the flow of the working fluid through the piping system. The launcher attaches to the valved ends of a piping system so that fluids in the piping system can recirculate in a closed loop. The method comprises attaching the launcher to the piping system, supplying the launcher with working fluid, admitting the device into the launcher, pumping the working fluid in the direction and at the rate desired so that the device moves through the piping system for pipe cleaning or inspection, removing the device from the launcher, and collecting the working fluid contained in the launcher. 8 figs.

Zollinger, W.T.; Appel, D.K.; Lewis, G.W.

1995-07-18T23:59:59.000Z

163

Heat pipes and use of heat pipes in furnace exhaust  

DOE Patents (OSTI)

An array of a plurality of heat pipe are mounted in spaced relationship to one another with the hot end of the heat pipes in a heated environment, e.g. the exhaust flue of a furnace, and the cold end outside the furnace. Heat conversion equipment is connected to the cold end of the heat pipes.

Polcyn, Adam D. (Pittsburgh, PA)

2010-12-28T23:59:59.000Z

164

Non-binding conductor load bearing roller for a gas-insulated transmission line having a corrugated outer conductor  

DOE Patents (OSTI)

A gas-insulated transmission line includes a corrugated outer conductor, an inner conductor disposed within and insulated from the outer conductor by means of support insulators and an insulating gas, and a non-binding transport device for supporting and permitting movement of the inner conductor/insulating support assembly axially along the corrugated outer conductor without radial displacement and for moving without binding along corrugations of any slope less than vertical. The transport device includes two movable contacts, such as skids or rollers, supported on a common pivot lever, the pivot lever being rotatably disposed about a pivot lever axis, which pivot lever axis is in turn disposed on the periphery of a support insulator or particle trap if one is used. The movable contacts are separated axially a distance equal to the axial distance between the peaks and valleys of the corrugations of the outer conductor and separated radially a distance equal to the radial distance between the peaks and valleys of the corrugations of the outer conductor. The transport device has the pivot lever axis disposed parallel to the motion of travel of the inner conductor/insulating support assembly.

Fischer, William H. (Pittsburgh, PA)

1984-01-01T23:59:59.000Z

165

Heat pipe array heat exchanger  

DOE Patents (OSTI)

A heat pipe arrangement for exchanging heat between two different temperature fluids. The heat pipe arrangement is in a ounterflow relationship to increase the efficiency of the coupling of the heat from a heat source to a heat sink.

Reimann, Robert C. (Lafayette, NY)

1987-08-25T23:59:59.000Z

166

Piping inspection instrument carriage  

DOE Patents (OSTI)

This invention, an instrument carriage for inspection of piping, comprises front and rear leg assemblies for engaging the interior of the piping and supporting and centering the carriage therein, an instrumentation arm carried by a shaft system running from front to rear leg assemblies. The shaft system has a screw shaft for moving the arm axially and a spline gear for moving the arm azimuthally. The arm has a pair of air cylinders that raise and lower a plate in the radial direction. On the plate are probes including, an eddy current probe and an ultrasonic testing probe. The ultrasonic testing probe is capable of spinning 360[degrees] about its axis.

Hapstack, M.; Talarek, T.R.; Zollinger, W.T.; Heckendorn, F.M. II; Park, L.R.

1991-01-01T23:59:59.000Z

167

Piping inspection instrument carriage  

DOE Patents (OSTI)

This invention, an instrument carriage for inspection of piping, comprises front and rear leg assemblies for engaging the interior of the piping and supporting and centering the carriage therein, an instrumentation arm carried by a shaft system running from front to rear leg assemblies. The shaft system has a screw shaft for moving the arm axially and a spline gear for moving the arm azimuthally. The arm has a pair of air cylinders that raise and lower a plate in the radial direction. On the plate are probes including, an eddy current probe and an ultrasonic testing probe. The ultrasonic testing probe is capable of spinning 360{degrees} about its axis.

Hapstack, M.; Talarek, T.R.; Zollinger, W.T.; Heckendorn, F.M. II; Park, L.R.

1991-12-31T23:59:59.000Z

168

Gas  

Science Conference Proceedings (OSTI)

... Implements a gas based on the ideal gas law. It should be noted that this model of gases is niave (from many perspectives). ...

169

Gas compressor with side branch absorber for pulsation control  

SciTech Connect

A method and system for reducing pulsation in lateral piping associated with a gas compressor system. A tunable side branch absorber (TSBA) is installed on the lateral piping. A pulsation sensor is placed in the lateral piping, to measure pulsation within the piping. The sensor output signals are delivered to a controller, which controls actuators that change the acoustic dimensions of the SBA.

Harris, Ralph E. (San Antonio, TX); Scrivner, Christine M. (San Antonio, TX); Broerman, III, Eugene L. (San Antonio, TX)

2011-05-24T23:59:59.000Z

170

Thailand gas project now operational  

SciTech Connect

Now operational, Phase 1 of Thailand's first major natural gas system comprises one of the world's longest (264 miles) offshore gas lines. Built for the Petroleum Authority of Thailand (PTT), this system delivers gas from the Erawan field in the Gulf of Thailand to two electrical power plants near Bangkok, operated by the Electricity Generating Authority of Thailand (EGAT). The project required laying about 360 miles of pipeline, 34-in., 0.625 in.-thick API-5LX-60 pipe offshore and 28-in., 0.406 in.-thick API-5LX-60 onshore. The offshore pipe received a coal-tar coating, a 3.5-5.0 in. concrete coating, and zinc sacrificial-anode bracelets. The onshore line was coated with the same coal-tar enamel and, where necessary, with concrete up to 4.5 in. thick. Because EGAT's two power plants are the system's only customers, no more pipeline will be constructed until deliveries, currently averaging about 100 million CF/day, reach the 250 million CF/day level. The project's second phase will include additional pipelines as well as an onshore distribution network to industrial customers.

Horner, C.

1982-08-01T23:59:59.000Z

171

SEISMIC DESIGN EVALUATION GUIDELINES FOR BURIED PIPING FOR THE DOE HLW FACILITIES'  

Office of Scientific and Technical Information (OSTI)

6 1 6 1 7 1 1 SEISMIC DESIGN EVALUATION GUIDELINES FOR BURIED PIPING FOR THE DOE HLW FACILITIES' Chi-Wen Lin Consultant, Martinez, CA George Antaki Westinghouse Savannah River Co., Aiken, SC Kamal Bandyopadhyay Brookhaven National Lab., Upton, NY ABSTRACT This paper presents the seismic design and evaluation guidelines for underground piping for the Department of Energy (DOE) High-Level-Waste (HLW) Facilities. The underground piping includes both single and double containment steel pipes and concrete pipes with steel lining, with particular emphasis on the double containment piping. The design and evaluation guidelines presented in this paper follow the generally accepted beam-on-elastic- foundation analysis principle and the inertial response calculation method, respectively, for piping directly

172

Waste heat recovery system having thermal sleeve support for heat pipe  

SciTech Connect

A system for recovering waste heat from a stream of heated gas is disclosed. The system includes a convection heat transfer chamber, a boiler tank, and a plurality of heat pipes thermally interconnecting the convection heat transfer chamber with the boiler tank. Each of the heat pipes includes an evaporator section which is disposed in heat transfer relation with a stream of heated gas flowing through the convection heat transfer chamber, and a condenser section disposed in heat transfer relation with a volume of water contained within the boiler tank. The boiler tank is provided with a header plate having an array of heat pipe openings through which the heat pipes project. A heat pipe support sleeve is received in each heat pipe opening in sealed engagement with the header plate, with the heat pipes projecting through the support sleeves and thermally interconnecting the convection heat transfer chamber with the boiler tank. An intermediate portion of each heat pipe is received in sealed engagement with its associated support sleeve. In a preferred embodiment, heat transfer through the support sleeve is minimized in an arrangement in which each heat pipe opening is reduced by a stepped bore with the support sleeve connected in threaded, sealed engagement with the stepped bore. Futhermore, in this arrangement, the support sleeve has swaged end portions which project beyond the header plate and engage the heat pipe on opposite sides at points which are remote with respect to the support sleeve/header plate interface. One of the swages end portions is sealed against the heat pipe in a fluid-tight union within the boiler tank. The support sleeve is radially spaced with respect to the heat pipe, and is also radially spaced with respect to the heat pipe opening whereby heat transfer through the walls of the heat pipe to the support sleeve and to the header plate is minimized by concentric annular air gaps.

McCurley, J.

1984-01-24T23:59:59.000Z

173

Waste heat recovery system having thermal sleeve support for heat pipe  

SciTech Connect

A system for recovering waste heat from a stream of heated gas is disclosed. The system includes a convection heat transfer chamber, a boiler tank, and a plurality of heat pipes thermally interconnecting the convection heat transfer chamber with the boiler tank. Each of the heat pipes includes an evaporator section which is disposed in heat transfer relation with a stream of heated gas flowing through the convection heat transfer chamber, and a condenser section disposed in heat transfer relation with a volume of water contained within the boiler tank. The boiler tank is provided with a header plate having an array of heat pipe openings through which the heat pipes project. A heat pipe support sleeve is received in each heat pipe opening in sealed engagement with the header plate, with the heat pipes projecting through the support sleeves and thermally interconnecting the convection heat transfer chamber with the boiler tank. An intermediate portion of each heat pipe is received in sealed engagement with its associated support sleeve. In a preferred embodiment, heat transfer through the support sleeve is minimized in an arrangement in which each heat pipe opening is reduced by a stepped bore with the support sleeve connected in threaded, sealed engagement with the stepped bore. Furthermore, in this arrangement, the support sleeve has swaged end portions which project beyond the header plate and engage the heat pipe on opposite sides at points which are remote with respect to the support sleeve/header plate interface. One of the swaged end portions is sealed against the heat pipe in a fluid-tight union within the boiler tank. The support sleeve is radially spaced with respect to the heat pipe, and is also radially spaced with respect to the heat pipe opening whereby heat transfer through the walls of the heat pipe to the support sleeve and to the header plate is minimized by concentric annular air gaps.

McCurley, J.

1984-04-10T23:59:59.000Z

174

Waste heat recovery system having thermal sleeve support for heat pipe  

SciTech Connect

A system for recovering waste heat from a stream of heated gas is disclosed. The system includes a convection heat transfer chamber, a boiler tank, and a plurality of heat pipes thermally interconnecting the convection heat transfer chamber with the boiler tank. Each of the heat pipes includes an evaporator section which is disposed in heat transfer relation with a stream of heated gas flowing through the convection heat transfer chamber, and a condenser section disposed in heat transfer relation with a volume of water contained within the boiler tank. The boiler tank is provided with a header plate having an array of heat pipe openings through which the heat pipes project. A heat pipe support sleeve is received in each heat pipe opening in sealed engagement with the header plate, with the heat pipes projecting through the support sleeves and thermally interconnecting the convection heat transfer chamber with the boiler tank. An intermediate portion of each heat pipe is received in sealed engagement with its associated support sleeve. In a preferred embodiment, heat transfer through the support sleeve is minimized in an arrangement in which each heat pipe opening is reduced by a stepped bore with the support sleeve connected in threaded, sealed engagement with the stepped bore. Furthermore, in this arrangement, the support sleeve has swaged end portions which project beyond the header plate and engage the heat pipe on opposite sides at points which are remote with respect to the support sleeve/header plate interface. One of the swaged end portions is sealed against the heat pipe in a fluid-tight union within the boiler tank. The support sleeve is radially spaced with respect to the heat pipe and is also radially spaced with respect to the heat pipe opening whereby heat transfer through the walls of the heat pipe to the support sleeve and to the header plate is minimized by concentric annular air gaps.

McCurley, J.

1984-12-04T23:59:59.000Z

175

Heat pipe applications workshop report  

SciTech Connect

The proceedings of the Heat Pipe Applications Workshop, held at the Los Alamos Scientific Laboratory October 20-21, 1977, are reported. This workshop, which brought together representatives of the Department of Energy and of a dozen industrial organizations actively engaged in the development and marketing of heat pipe equipment, was convened for the purpose of defining ways of accelerating the development and application of heat pipe technology. Recommendations from the three study groups formed by the participants are presented. These deal with such subjects as: (1) the problem encountered in obtaining support for the development of broadly applicable technologies, (2) the need for applications studies, (3) the establishment of a heat pipe technology center of excellence, (4) the role the Department of Energy might take with regard to heat pipe development and application, and (5) coordination of heat pipe industry efforts to raise the general level of understanding and acceptance of heat pipe solutions to heat control and transfer problems.

Ranken, W.A.

1978-04-01T23:59:59.000Z

176

Fracture Optimization eXpert (FOX) -How Computational Intelligence Helps the Bottom-Line in Gas Storage; A Case Study  

E-Print Network (OSTI)

. The understanding of this value concept is to a natural gas storage pool: the top gas capacity, the first to expand a market for natural gas ing side, though, the storage pool cap/del working unit is storage case is established. The actual incremental increases in expansion. value of the natural gas storage

Mohaghegh, Shahab

177

Drill pipe protector development  

DOE Green Energy (OSTI)

The Geothermal Drilling Organization (GDO), formed in the early 1980s by the geothermal industry and the U.S. Department of Energy (DOE) Geothermal Division, sponsors specific development projects to advance the technologies used in geothermal exploration, drilling, and production phases. Individual GDO member companies can choose to participate in specific projects that are most beneficial to their industry segment. Sandia National Laboratories is the technical interface and contracting office for the DOE in these projects. Typical projects sponsored in the past have included a high temperature borehole televiewer, drill bits, muds/polymers, rotary head seals, and this project for drill pipe protectors. This report documents the development work of Regal International for high temperature geothermal pipe protectors.

Thomerson, C.; Kenne, R. [Regal International Corp., Corsicanna, TX (United States); Wemple, R.P. [Sandia National Lab., Albuquerque, NM (United States)] [ed.] [and others

1996-03-01T23:59:59.000Z

178

Integrity assurance of natural gas transmission pipelines  

Science Conference Proceedings (OSTI)

Natural gas transmission pipelines have proven to be a safe and efficient means for transporting the trillions of cubic feet of natural gas used annually in the United States. Since the peak of construction of these pipelines occurred between 1950 and the mid-1960s, their average age is now over thirty years. However, replacement of these pipelines because of age would be prohibitively expensive and unnecessary. Preventive maintenance and rehabilitation programs put into practice by the pipeline industry provides the key to ensuring the continued integrity of the transmission pipeline system. This article reviews the preventive maintenance practices commonly used by the gas industry. These practices include right-of-way patrols, corrosion control procedures, in-line inspection with intelligent or smart pigs that inspect the pipe while traveling through the inside of the pipe, direct access inspection of the pipe from bellhole excavations, and hydrostatic retesting of pipelines. When pipelines are properly maintained, these practices can ensure the integrity and long-term serviceability of transmission pipelines well into the 21st Century. 11 refs., 5 figs., 1 tab.

Posakony, G.J. (J-TECH Consulting, Richland, WA (United States))

1993-05-01T23:59:59.000Z

179

Pipe-to-pipe impact analysis - Nuclear Engineering Multimedia  

NLE Websites -- All DOE Office Websites (Extended Search)

Pipe-to-pipe impact analysis Pipe-to-pipe impact analysis Director's Welcome Organization Achievements Highlights Fact Sheets, Brochures & Other Documents Multimedia Library About Nuclear Energy Nuclear Reactors Designed by Argonne Argonne's Nuclear Science and Technology Legacy Opportunities within NE Division Visit Argonne Work with Argonne Contact us For Employees Site Map Help Join us on Facebook Follow us on Twitter NE on Flickr Celebrating the 70th Anniversary of Chicago Pile 1 (CP-1) Argonne OutLoud on Nuclear Energy Argonne Energy Showcase 2012 Engineering Analysis Multimedia Bookmark and Share EA Multimedia, a collection of videos and audios featuring activities related to the Engineering Analysis Department Pipe-to-pipe impact analysis Quicktime video Quicktime Format - High Bandwidth | Size: 12 MB | Bit Rate:

180

Waste heat recovery system having thermal sleeve support for heat pipe  

SciTech Connect

A system for recovering waste heat from a stream of heated gas is disclosed. The system includes a convection heat transfer chamber, a boiler tank, and a plurality of heat pipes thermally interconnecting the convection heat transfer chamber with the boiler tank. Each of the heat pipes includes an evaporator section which is disposed in heat transfer relation with a stream of heated gas flowing through the convection heat transfer chamber, and a condenser section disposed in heat transfer relation with a volume of water contained within the boiler tank. The boiler tank is provided with a header plate having an array of heat pipe openings through which the heat pipes project. A heat support sleeve is received in each heat pipe opening in sealed engagement with the header plate, with the heat pipes projecting through the support sleeves and thermally interconnecting the convection heat transfer chamber with the boiler tank. An intermediate portion of each heat pipe is received in sealed engagement with its associated support sleeve. In a preferred embodiment, heat transfer through the support sleeve is minimized in an arrangement in which each heat pipe opening is reduced by a stepped bore with the support sleeve connected in threaded, sealed engagement with the stepped bore. Furthermore, in this arrangement, the support sleeve has swaged end portions which project beyond the header plate and engage the heat pipe on opposite sides at points which are remote with respect to the support sleeve/header plate interface. One of the swaged end portions is sealed against the heat pipe in a fluid-tight union within the boiler tank. The support sleeve is radially spaced with respect to the heat pipe, and is also radially spaced with respect to the heat pipe opening whereby heat transfer through the walls of the heat pipe to the support sleeve and to the header plate is minimized by concentric annular air gaps.

McCurley, J.

1984-12-18T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Pipe Insulation Economies  

E-Print Network (OSTI)

Pipe Insulation Economies is a computer program written in IBM basic to simplify the economic insulation thickness for an insulated pipe. Many articles have been written on this subject, from simple nomographs to a small book written in 1976 by the Federal Energy Administration, called "Economic Thickness for Industrial Insulation (ETI)." This paper is meant to fall somewhere between these extremes without sacrificing the accuracy necessary for economic considerations. Within this text, insulation is dealt with not as a material but as a method to slow heat transfer. To simplify the various mechanisms by which heat is transferred, the variable "thermal conductivity" is used. This is modeled for average insulation temperature. Another variable which has caused problems in the past is the ambient air film coefficient, or surface resistance. This program deals with this coefficient by making an initial assumption, then using an iterative process to refine the actual values before making the economic calculations. The program will use the input data to determine first of all the heat loss in BTU per hr/ft. of pipe. Using this result the lowest annual cost, therefore the most economical insulation thickness, is determined.

Schilling, R. E.

1986-06-01T23:59:59.000Z

182

CORE LEVITATION IN THE EGCR IN CASE OF MAIN COOLANT PIPE FAILURE  

SciTech Connect

Results of an analysis to determine the extent of displacement of the EGCR core due to blowdown in case of several postulated hot main gas coolant pipe failures are summarized. Results show that the core will be damaged for ary hot pipe double-ended failure. Excepting the improbable case of no coolant flow existing prior to the break, the core will be damaged for any hot pipe fracture exposing a total flow area to the atmosphere equal to that of one pipe. Smaller breaks will probably be safe in this respect. (auth)

Fontana, M.H.

1959-08-04T23:59:59.000Z

183

Project W-320, 241-C-106 sluicing: Piping calculations. Volume 4  

SciTech Connect

This supporting document has been prepared to make the FDNW calculations for Project W-320 readily retrievable. The objective of this calculation is to perform the structural analysis of the Pipe Supports designed for Slurry and Supernate transfer pipe lines in order to meet the requirements of applicable ASME codes. The pipe support design loads are obtained from the piping stress calculations W320-27-I-4 and W320-27-I-5. These loads are the total summation of the gravity, pressure, thermal and seismic loads. Since standard typical designs are used for each type of pipe support such as Y-Stop, Guide and Anchors, each type of support is evaluated for the maximum loads to which this type of supports are subjected. These loads are obtained from the AutoPipe analysis and used to check the structural adequacy of these supports.

Bailey, J.W.

1998-07-24T23:59:59.000Z

184

Seismic design evaluation guidelines for buried piping for the DOE HLW Facilities  

SciTech Connect

This paper presents the seismic design and evaluation guidelines for underground piping for the Department of Energy (DOE) High-Level-Waste (HLW) Facilities. The underground piping includes both single and double containment steel pipes and concrete pipes with steel lining, with particular emphasis on the double containment piping. The design and evaluation guidelines presented in this paper follow the generally accepted beam-on-elastic-foundation analysis principle and the inertial response calculation method, respectively, for piping directly in contact with the soil or contained in a jacket. A standard analysis procedure is described along with the discussion of factors deemed to be significant for the design of the underground piping. The following key considerations are addressed: the design feature and safety requirements for the inner (core) pipe and the outer pipe; the effect of soil strain and wave passage; assimilation of the necessary seismic and soil data; inertial response calculation for the inner pipe; determination of support anchor movement loads; combination of design loads; and code comparison. Specifications and justifications of the key parameters used, stress components to be calculated and the allowable stress and strain limits for code evaluation are presented.

Lin, Chi-Wen [Consultant, Martinez, CA (United States); Antaki, G. [Westinghouse Savannah River Co., Aiken, SC (United States); Bandyopadhyay, K. [Brookhaven National Lab., Upton, NY (United States); Bush, S.H. [Review & Synthesis Association, Richland, WA (United States); Costantino, C. [City Univ. of New York, New York, NY (United States); Kennedy, R. [RPK Structural Mechanics, Yorba Linda, CA (United States). Consultant

1995-05-01T23:59:59.000Z

185

Automated welding of nuclear piping systems  

SciTech Connect

Automated welding, or more broadly, automatic and mechanized welding processes, has found a role in nuclear power plant fabrication. This role has expanded from a rare or isolated application to relatively frequent usage in the last five years. More importantly, it is envisioned that use of automated welding will be increasing at an accelerated rate as broader exposure to this technology is achieved. Among the various pipe welding processes, the only one which has been developed for mechanized and automated nuclear piping welding is the gas tungsten arc welding (GTAW) process. This development has occurred in the past 10 to 15 years through the steady improvement and commmercialization of orbiting welding heads. Improvements in GTAW power supplies, control systems, etc., have aided this commercialization but the main element and pacing item has been the welding head itself. In order to review the status of mechanized and automated nuclear pipe welding, the topics of basic process equipment, joint design, fit-up requirements, welding parameters, and producibility will be addressed. In addition, anticipated future developments in automated systems will be discussed.

Hood, D.W.

1979-01-01T23:59:59.000Z

186

Deployment, release and recovery of ocean riser pipes  

DOE Patents (OSTI)

An ocean thermal energy conversion facility includes a long pipe assembly which is supported at its upper end by the hull of the floating facility. Cold water flows to the facility from deep in the ocean. The pipe assembly comprises an elongate pipe construction and a weight connected to the lower end of the construction by a line of selected length. A floatation collar is connected to the construction at its upper end to cause the construction to have positive buoyancy and a center of buoyancy closer to the upper end of the construction than its center of mass. The weight renders the entire pipe assembly negatively buoyant. In the event that support of the pipe assembly should be lost, as by release of the assembly from the facility hull in an emergency, the assembly sinks to the ocean floor where it is moored by the weight. The pipe construction floats submerged above the ocean floor in a substantially vertical attitude which facilitates recovery of the assembly.

Person, Abraham (Los Alamitos, CA); Wetmore, Sherman B. (Westminster, CA); McNary, James F. (Santa Ana, CA)

1980-11-18T23:59:59.000Z

187

Entirely passive heat pipe apparatus capable of operating against gravity  

DOE Patents (OSTI)

The disclosure is directed to an entirely passive heat pipe apparatus capable of operating against gravity for vertical distances in the order of 3 to 7 meters and more. A return conduit into which an inert gas is introduced is used to lower the specific density of the working fluid so that it may be returned a greater vertical distance from condenser to evaporator.

Koenig, Daniel R. (Santa Fe, NM)

1982-01-01T23:59:59.000Z

188

Selenide isotope generator for the Galileo Mission. Axially-grooved heat pipe: accelerated life test results  

SciTech Connect

The results through SIG/Galileo contract close-out of accelerated life testing performed from June 1978 to June 1979 on axially-grooved, copper/water heat pipes are presented. The primary objective of the test was to determine the expected lifetime of axially-grooved copper/water heat pipes. The heat pipe failure rate, due to either a leak or a build-up of non-condensible gas, was determined. The secondary objective of the test was to determine the effects of time and temperature on the thermal performance parameters relevant to long-term (> 50,000 h) operation on a space power generator. The results showed that the gas generation rate appears to be constant with time after an initial sharp rise although there are indications that it drops to approximately zero beyond approx. 2000 h. During the life test, the following pipe-hours were accumulated: 159,000 at 125/sup 0/C, 54,000 at 165/sup 0/C, 48,000 at 185/sup 0/C, and 8500 at 225/sup 0/C. Heated hours per pipe ranged from 1000 to 7500 with an average of 4720. Applying calculated acceleration factors yields the equivalent of 930,000 pipe-h at 125/sup 0/C. Including the accelerated hours on vendor tested pipes raises this number to 1,430,000 pipe-hours at 125/sup 0/C. It was concluded that, for a heat pipe temperature of 125/sup 0/C and a mission time of 50,000 h, the demonstrated heat pipe reliability is between 80% (based on 159,000 actual pipe-h at 125/sup 0/C) and 98% (based on 1,430,000 accelerated pipe-h at 125/sup 0/C). Measurements indicate some degradation of heat transfer with time, but no detectable degradation of heat transport. (LCL)

1979-08-01T23:59:59.000Z

189

Evaluation of Trenchless Installation Technology for Radioactive Wastewater Piping Applications  

SciTech Connect

The U.S. Department of Energy (DOE) Office of Environmental Management (EM) cleanup mission at Oak Ridge National Laboratory (ORNL) includes dispositioning facilities, contaminated legacy materials/waste, and contamination sources and remediation of soil under facilities, groundwater, and surface water to support final Records of Decision (RODs). The Integrated Facilities Disposition Project (IFDP) is a roughly $15B project for completion of the EM mission at Oak Ridge, with a project duration of up to 35 years. The IFDP Mission Need Statement - Critical Decision-0 (CD-0) - was approved by DOE in July 2007, and the IFDP Alternative Selection and Cost Range - Critical Decision-1 (CD-1) - was approved in November 2008. The IFDP scope includes reconfiguration of waste collection and treatment systems as needed to complete the IFDP remediation and decontamination and decommissioning (D&D) missions in a safe and cost-effective manner while maintaining compliance with all governing regulations and bodies and preserving the support of continuing operations at ORNL. A step in the CD-1 approval process included an external technical review (ETR) of technical approaches proposed in the CD-1 document related to the facility reconfiguration for the ORNL radioactive waste and liquid low-level waste management systems. The ETR team recommended that the IFDP team consider the use of trenchless technologies for installing pipelines underground in and around contaminated sites as part of the alternatives evaluations required in support of the CD-2 process. The team specifically recommended evaluating trenchless technologies for installing new pipes in existing underground pipelines as an alternative to conventional open trench installation methods. Potential benefits could include reduction in project costs, less costly underground piping, fewer disruptions of ongoing and surface activities, and lower risk for workers. While trenchless technologies have been used extensively in the sanitary sewer and natural gas pipeline industries, they have been used far less in contaminated environments. Although trenchless technologies have been used at ORNL in limited applications to install new potable water and gas lines, the technologies have not been used in radioactive applications. This study evaluates the technical risks, benefits, and economics for installing gravity drained and pressurized piping using trenchless technologies compared to conventional installation methods for radioactive applications under ORNL geological conditions. A range of trenchless installation technologies was reviewed for this report for general applicability for replacing existing contaminated piping and/or installing new pipelines in potentially contaminated areas. Installation methods that were determined to have potential for use in typical ORNL contaminated environments were then evaluated in more detail for three specific ORNL applications. Each feasible alternative was evaluated against the baseline conventional open trench installation method using weighted criteria in the areas of environment, safety, and health (ES&H); project cost and schedule; and technical operability. The formulation of alternatives for evaluation, the development of selection criteria, and the scoring of alternatives were performed by ORNL staff with input from vendors and consultants. A description of the evaluation methodology and the evaluation results are documented in the following sections of this report.

Robinson, Sharon M [ORNL; Jubin, Robert Thomas [ORNL; Patton, Bradley D [ORNL; Sullivan, Nicholas M [ORNL; Bugbee, Kathy P [ORNL

2009-09-01T23:59:59.000Z

190

Nondestructive Evaluation Instrument Surveillance Test on 26-Inch Pipe  

Science Conference Proceedings (OSTI)

Tests simulating an operating-reactor environment provided valuable information on crack initiation and growth as well as on continuous on-line monitoring. This pioneering research has resulted in an industry standard that will reduce the costs and complexity of piping inspection and repair.

1984-01-01T23:59:59.000Z

191

Power Line-Induced AC Potential on Natural Gas Pipelines for Complex Rights-of-Way Configurations, Volume 1: Engineering Analysis  

Science Conference Proceedings (OSTI)

This report addresses complex common corridor coupling problems for overhead electric power transmission lines and buried natural gas pipelines. Volume 1 describes the development of analytic methods for solving such problems and presents field data used in verification efforts. Volume 2 is a handbook for graphic analysis designed for use by field personnel or others without access to a computer. Volume 3 is a user's guide for the PIPELINE computer code.

1983-05-01T23:59:59.000Z

192

Use of a Heated Transfer Line-Membrane Interface Probe to Characterize Polycyclic Aromatic Hydrocarbons at a Manufactured Gas Plant Site  

Science Conference Proceedings (OSTI)

This report describes bench-scale and field pilot tests of a system integrating a heated transfer line (HTL) and a membrane interface probe (MIP) with commercially available analytical instruments and software. Driven into the subsurface by a cone penetrometer, the HTL-MIP thermally extracts organic compounds from saturated and unsaturated soils at former manufactured gas plant (MGP) sites. The integrated system detects compounds using a screening photo-ionization detector (PID) and analyzes them in situ...

2008-04-30T23:59:59.000Z

193

Aerogel Impregnated Polyurethane Piping and Duct Insulation ...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Polyurethane Piping and Duct Insulation Aerogel Impregnated Polyurethane Piping and Duct Insulation Emerging Technologies Project for the 2013 Building Technologies Office's...

194

Pipe crawler with stabilizing midsection  

DOE Patents (OSTI)

A pipe crawler is described having a midsection that provides the stability and flexibility to allow the pipe crawler to negotiate curved and uneven segments of piping while traveling through piping systems. The pipe crawler comprises a front leg assembly, a rear leg assembly, a midsection with a gimbal at each end for connecting the midsection to the front and rear leg assemblies in a flexible manner, and an air cylinder for changing the distance between the front and rear leg assemblies. The pipe crawler moves in ''inch worm'' fashion with the front and rear leg assemblies alternating between an extended and a retracted position as the air cylinder moves the retracted leg assembly forward. The midsection has a plurality of legs extending radially for holding the midsection within a maximum displacement from the piping axis so that the gimbals are not pivoted to extreme angles where they might lock up or seize. When the midsection is displaced sufficiently, its legs with wheels on each end engage the interior surface of the piping and prevent further displacement. Using two gimbals divides the angle between the planes defined by the front and rear leg assemblies which also helps to prevent excessive gimbal pivoting. 5 figures.

Zollinger, W.T.; Treanor, R.C.

1994-12-27T23:59:59.000Z

195

Geothermal district piping - A primer  

DOE Green Energy (OSTI)

Transmission and distribution piping constitutes approximately 40 -60% of the capital costs of typical geothermal district heating systems. Selections of economical piping suitable for the fluid chemistry is critical. Presently, most piping (56%) in geothermal systems is of asbestos cement construction. Some fiberglass (19%) and steel (19%) is also in use. Identification of an economical material to replace asbestos cement is important to future project development. By providing information on relative costs, purchase considerations, existing material performance and new products, this report seeks to provide a background of information to the potential pipe purchaser. A brief discussion of the use of uninsulated piping in geothermal district heating systems is also provided. 5 refs., 19 figs., 1 tab.

Rafferty, K.

1989-11-01T23:59:59.000Z

196

Solar heat pipe feedback turbogenerator  

SciTech Connect

The conversion of radiant heat to electricity by a heat pipe-turbogenerator combination is described. The heat pipe-tubogenerator assembly is suitably externally insulated, as by a vacuum shield, to prevent heat losses and heat is recovered from the condenser portion of the heat pipe and returned to the evaporator portions. An application of the generic invention is discussed which it is employed on wall or roof portions of a building and serves as at least a partial supporting structure for these. In another application the solar heat pipe feedback turbogenerator may be incorporated in or used with reflective means, such as reflective sheet material of large area positioned to direct solar radiation onto the evaporator section of the heat pipe. The reflective means may be changed in position to follow the sun to produce maximum power during operation.

Decker, B.J.

1978-10-24T23:59:59.000Z

197

Functional capability of piping systems  

SciTech Connect

General Design Criterion I of Appendix A to Part 50 of Title 10 of the Code of Federal Regulations requires, in part, that structures, systems, and components important to safety be designed to withstand the effects of earthquakes without a loss of capability to perform their safety function. ne function of a piping system is to convey fluids from one location to another. The functional capability of a piping system might be lost if, for example, the cross-sectional flow area of the pipe were deformed to such an extent that the required flow through the pipe would be restricted. The objective of this report is to examine the present rules in the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section III, and potential changes to these rules, to determine if they are adequate for ensuring the functional capability of safety-related piping systems in nuclear power plants.

Terao, D.; Rodabaugh, E.C.

1992-11-01T23:59:59.000Z

198

Pressure vessel and piping codes  

SciTech Connect

Section III of the ASME Boiler and Pressure Vessel Code contains simplified design formulas for placing bounds on the plastic deformations in nuclear power plant piping systems. For Class 1 piping a simple equation is given in terms of primary load stress indices (B/sub 1/ and B/sub 2/) and nominal pressure and bending stresses. The B/sub 1/ and B/sub 2/ stress indices reflect the capacities of various piping products to carry load without gross plastic deformation. In this paper, the significance of the indices, nominal stresses, and limits given in the Code for Class 1 piping and corresponding requirements for Class 2 and Class 3 piping are discussed. Motivation behind recent (1978-1981) changes in the indices and in the associated stress limits is presented.

Moore, S.E.; Rodabaugh, E.C.

1982-11-01T23:59:59.000Z

199

Instantaneous gas water heater  

SciTech Connect

Hot water supply temperature is set by a temperature setting device in response to an instantaneous flow rate signal from a water flow rate sensor arranged in a water supply pipe and a feeding water temperature signal from a feeding water temperature sensor which are compared with a predetermined hot water supply temperature and calculated in a control unit. A proportional valve and other devices in a gas supply pipe are controlled in response to the result of the comparison and calculation to define a required volume of gas for ignition and heating. At the same time, a fan damper is controlled by a damper control device so as to adjust the volume of combustion air. A signal representing discharging hot water temperature from a discharging hot water temperature sensor arranged in a hot water feeding pipe is fed back to the control unit and calculated therein, and a valve in the hot water supply pipe is adjusted in response to the result of calculation to attain the desired hot water supply temperature. In order to prevent freezing in the system in winter season, a signal from a thermostat in the water feeding pipe is transmitted to a heater arranged in an air supply chamber so as to heat a heat exchanger pipe and, at the same time, heaters arranged in the water feeding pipe and the hot water supply pipe are also controlled to prevent freezing.

Tsutsui, O.; Kuwahara, H.; Murakami, Sh.; Yasunaga, Sh.

1985-02-26T23:59:59.000Z

200

Heat pipe technology quarterly literature review. Volume 1, Number 3  

SciTech Connect

A bibliography containing 110 citations is presented. The citations are arranged in five sections on general information on heat pipes, heat pipe applications, heat pipe theory, heat pipe design, development, and fabrication, and heat pipe testing and operation.

Srinivasan, R.; Gonzales, R.W. (eds.)

1983-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Micro-Columnated Loop Heat Pipe: The Future of Electronic Substrates  

E-Print Network (OSTI)

Loop Heat Pipes . . . . . . . . . . . . . . . . . . . .Heat Pipes . . . . . . . . . . . . . . . . . . . . . . . .of operation of a heat pipe [13]. . . . . . . . . . . . . .

Dhillon, Navdeep Singh

2012-01-01T23:59:59.000Z

202

Clean Lines: Strategies for Reducing Your Environmental ...  

Science Conference Proceedings (OSTI)

... Flow restrictors to prevent the flow in a water-supply pipe from exceeding a ... On manual lines, racks can be hung on bars over process baths to allow ...

2013-08-16T23:59:59.000Z

203

Electrical Transmission Line Diametrical Retention Mechanism  

DOE Patents (OSTI)

The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within downhole components. The invention allows a transmission line to be attached to the internal diameter of drilling components that have a substantially uniform drilling diameter. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to withstand the tension and compression of drill pipe during routine drilling cycles.

Hall, David R. (Provo, UT); Hall, Jr., H. Tracy (Provo, UT); Pixton, David (Lehi, UT); Dahlgren, Scott (Provo, UT); Sneddon, Cameron (Provo, UT); Briscoe, Michael (Lehi, UT); Fox, Joe (Spanish Fork, UT)

2006-01-03T23:59:59.000Z

204

Heat pipe transient response approximation.  

SciTech Connect

A simple and concise routine that approximates the response of an alkali metal heat pipe to changes in evaporator heat transfer rate is described. This analytically based routine is compared with data from a cylindrical heat pipe with a crescent-annular wick that undergoes gradual (quasi-steady) transitions through the viscous and condenser boundary heat transfer limits. The sonic heat transfer limit can also be incorporated into this routine for heat pipes with more closely coupled condensers. The advantages and obvious limitations of this approach are discussed. For reference, a source code listing for the approximation appears at the end of this paper.

Reid, R. S. (Robert Stowers)

2001-01-01T23:59:59.000Z

205

Light pipe - design for efficiency  

Science Conference Proceedings (OSTI)

The high cost and availability of materials which are clear enough to transmit light without absorption has limited the idea of piping large-scale quantities of light. The light pipe uses the principle of Total Internal Reflection, with the light guided by very accurate prisms. The transmission of light directed into the end of a Light Pipe at an angle of less than 27.6 degrees is theoretically 100% efficient. The author describes its uses and advantages for lighting offices, cold storage areas, difficult access and hazardous areas, and for solar lighting. Future directions will be to improve the economics and accuracy of the technology. 4 references, 2 figures.

Hockey, S.N.

1985-08-01T23:59:59.000Z

206

Leachate storage transport tanker loadout piping  

Science Conference Proceedings (OSTI)

This report shows the modifications to the W-025 Trench No. 31 leachate loadout discharge piping, and also the steps involved in installing the discharge piping, including dimensions and welding information. The installation of the discharge pipe should be done in accordance to current pipe installation standards. Trench No. 31 is a radioactive mixed waste land disposal facility.

Whitlock, R.W.

1994-11-18T23:59:59.000Z

207

Heat-pipe development for high-temperature recuperator application  

SciTech Connect

Heat pipes have been developed for operation in oxidizing atmospheres at temperatures above 1100/sup 0/K. The heat pipes comprise a metallic liner and wick structure with a protective outer shell of an oxidation resistant material. The working fluids used in the heat pipes are alkali metals. A number of configurations have been evaluated, ranging from pipes using a metallic inner liner of a chemically vapor deposited (CVD) refractory metal applied to ceramic tubing, to one utilizing ferrous materials with an outer layer of a developed oxide. A promising intermediate configuration consisting of free-standing refractory tubing covered with a layered structure of fine grain, equi-axed CVD silicon carbide has also been evaluated. The test heat pipe was fabricated using low-carbon, arc-cast molybdenum tubing and a wick composed of 150 mesh molybdenum screen. Hafnium gettering was used with sodium working fluid. Assembly of the pipe was by electron beam welding. Following closure and capping of the fill tube the assembly was operated in a vacuum for several hours prior to the chemical vapor deposition of the exterior ceramic coating. After coating, the pipe was operated in air and in combustion gases for performance evaluation. The use of iron-chromium-aluminum alloys as container materials for operating in high temperature oxidizing and sulfiding gas streams has been investigated. Alloys of this type develop heavy, protective oxide surface layers when exposed to high temperature oxidizing atmospheres, and are commonly used in electrical heating elements because of their exceptional oxidation resistance.

Merrigan, M.; Dunwoody, W.; Lundberg, L.

1981-01-01T23:59:59.000Z

208

Thermal laminarization of a stratified pipe flow  

SciTech Connect

The present work constitutes a new program that grew out of a scoping assessment by ANL to determine the propensity for pipe stratification to occur in the reactor outlet nozzles and hot-leg piping of a generic LMFBR during events producing reverse pipe flow. This paper focuses on the role that thermal buoyancy plays relative to being able to laminarize a turbulent stratified shear zone in a horizontal pipe. The preceeding can influence the behavior of a pipe stratified-backflow-recirculation zone (cold plenum water down into the hot pipe flow) which developes as the result of a temperature difference between the pipe flow and the plenum.

Oras, J.J.; Kasza, K.E.

1984-01-01T23:59:59.000Z

209

Training reduces stuck pipe costs and incidents  

SciTech Connect

Properly administered initial and refresher stuck pipe training courses have dramatically reduced the cost and number of stuck pipe incidents for many companies worldwide. These training programs have improved operator and contractor crew awareness of stuck pipe risks and fostered a team commitment in averting such incidents. The success is evident in the achievements of the companies sponsoring such training. Preventing and minimizing stuck pipe is the most significant benefit of stuck pipe training, but crews also benefit from becoming more knowledgeable about the drilling program and equipment operation. The paper discusses stuck pipe costs, stuck pipe training, prevention of stuck pipes, well bore stability, geopressured formation, reactive formation, reactive formations, unconsolidated formations, mobile formations, fractured and faulted formations, differential sticking, 8 other causes of stuck pipe, and freeing stuck pipe.

Watson, B. (Global Marine Drilling Co., Houston, TX (United States)); Smith, R. (Randy Smith Drilling School, Lafayette, LA (United States))

1994-09-19T23:59:59.000Z

210

Nitrogen heat pipe for cryocooler thermal shunt  

SciTech Connect

A nitrogen heat pipe was designed, built and tested for the purpose of providing a thermal shunt between the two stages of a Gifford-McMahan (GM) cryocooler during cooldown. The nitrogen heat pipe has an operating temperature range between 63 and 123 K. While the heat pipe is in the temperature range during the system cooldown, it acts as a thermal shunt between the first and second stage of the cryocooler. The heat pipe increases the heat transfer to the first stage of the cryocooler, thereby reducing the cooldown time of the system. When the heat pipe temperature drops below the triple point, the nitrogen working fluid freezes, effectively stopping the heat pipe operation. A small heat leak between cryocooler stages remains because of axial conduction along the heat pipe wall. As long as the heat pipe remains below 63 K, the heat pipe remains inactive. Heat pipe performance limits were measured and the optimum fluid charge was determined.

Prenger, F.C.; Hill, D.D.; Daney, D.E.; Daugherty, M.A. [Los Alamos National Lab., NM (United States); Green, G.F.; Roth, E.W. [Naval Surface Warfare Center, Annapolis, MD (United States)

1995-09-01T23:59:59.000Z

211

Compilation of EPRI High Energy Piping Guidelines  

Science Conference Proceedings (OSTI)

Condition assessment programs for highenergy piping systems are often a major aspect of a fossil utilitys inspection and maintenance program. In the past 30 years, many major failures of fossil highenergy piping have been associated with flowaccelerated corrosion of feedwater piping, creep failures of longitudinal seamwelded hot reheat and main steam piping, and corrosion fatigue failures of cold reheat steam piping. In addition to these welldocumented failures, most utilities experience failures of supp...

2008-03-31T23:59:59.000Z

212

Corrugated pipe adhesive applicator apparatus  

DOE Patents (OSTI)

Apparatus for coating selected portions of the troughs of a corrugated pipe with an adhesive includes a support disposed within the pipe with a reservoir containing the adhesive disposed on the support. A pump, including a spout, is utilized for supplying the adhesive from the reservoir to a trough of the pipe. A rotatable applicator is supported on the support and contacts the trough of the pipe. The applicator itself is sized so as to fit within the trough, and contacts the adhesive in the trough and spreads the adhesive in the trough upon rotation. A trough shield, supported by the support and disposed in the path of rotation of the applicator, is utilized to prevent the applicator from contacting selected portions of the trough. A locator head is also disposed on the support and provides a way for aligning the spout, the applicator, and the trough shield with the trough. 4 figs.

Shirey, R.A.

1983-06-14T23:59:59.000Z

213

Corrugated pipe adhesive applicator apparatus  

DOE Patents (OSTI)

Apparatus for coating selected portions of the troughs of a corrugated pipe within an adhesive includes a support disposed within the pipe with a reservoir containing the adhesive disposed on the support. A pump, including a spout, is utilized for supplying the adhesive from the reservoir to a trough of the pipe. A rotatable applicator is supported on the support and contacts the trough of the pipe. The applicator itself is sized so as to fit within the trough, and contacts the adhesive in the trough and spreads the adhesive in the trough upon rotation. A trough shield, supported by the support and disposed in the path of rotation of the applicator, is utilized to prevent the applicator from contacting selected portions of the trough. A locator head is also disposed on the support and provides a way for aligning the spout, the applicator, and the trough shield with the trough.

Shirey, Ray A. (North Grafton, MA)

1983-06-14T23:59:59.000Z

214

Embedded Pipe Dose Calculation Method  

Science Conference Proceedings (OSTI)

Nuclear plants contain thousands of feet of process piping embedded in walls, ceilings, and floors, many of which have radioactive contamination on internal surfaces. Decommissioning of these plants requires determining the level and character of contamination and removing the activity to levels commensurate with requirements for disposal or release. This report investigates and evaluates some measurement techniques for determining activities on internal surfaces of embedded piping through a series of co...

2000-11-22T23:59:59.000Z

215

Pipe weld crown removal device  

DOE Patents (OSTI)

This invention is comprised of a device that provides for grinding down the crown of a pipe weld joining aligned pipe sections so that the weld is substantially flush with the pipe sections joined by the weld. The device includes a cage assembly comprising a pair of spaced cage rings adapted to be mounted for rotation on the respective pipe sections on opposite sides of the weld, a plurality of grinding wheels, supported by the cage assembly for grinding down the crown of the weld, and a plurality of support shafts, each extending longitudinally along the joined pipe sections, parallel thereto, for individually mounting respective grinding wheels. Each end of the support shafts is mounted for rotation in a bearing assembly housed within a radially directed opening in a corresponding one of the cage rings so as to provide radial movement of the associated shaft, and thus of the associated grinding wheel, towards and away from the weld. A first drive sprocket provides rotation of the cage assembly around the pipe sections while a second drive unit, driven by a common motor, provides rotation of the grinding wheels.

Sword, C.K.; Sette, P.J.

1991-12-31T23:59:59.000Z

216

Piping inspection round robin  

Science Conference Proceedings (OSTI)

The piping inspection round robin was conducted in 1981 at the Pacific Northwest National Laboratory (PNNL) to quantify the capability of ultrasonics for inservice inspection and to address some aspects of reliability for this type of nondestructive evaluation (NDE). The round robin measured the crack detection capabilities of seven field inspection teams who employed procedures that met or exceeded the 1977 edition through the 1978 addenda of the American Society of Mechanical Engineers (ASME) Section 11 Code requirements. Three different types of materials were employed in the study (cast stainless steel, clad ferritic, and wrought stainless steel), and two different types of flaws were implanted into the specimens (intergranular stress corrosion cracks (IGSCCs) and thermal fatigue cracks (TFCs)). When considering near-side inspection, far-side inspection, and false call rate, the overall performance was found to be best in clad ferritic, less effective in wrought stainless steel and the worst in cast stainless steel. Depth sizing performance showed little correlation with the true crack depths.

Heasler, P.G.; Doctor, S.R. [Pacific Northwest National Lab., Richland, WA (United States)

1996-04-01T23:59:59.000Z

217

Fiber-Optic Long-Line Position Sensor - Energy Innovation Portal  

Description Large-scale rotary drilling for oil and gas, minerals, and water wells have a need for measuring the depth of drill bits and pipe segments.

218

Methods for Cleaning and Evaluating Pipe-Type Cable Pipes for Retrofit with Extruded Dielectric Cable Systems  

Science Conference Proceedings (OSTI)

This report summarizes studies of pipe cleaning, "pigging," inspecting, and testing pipe-type cable pipes for re-conditioning as conduits compatible with extruded dielectric cables.

2001-12-12T23:59:59.000Z

219

CODIFICATION OF FIBER REINFORCED COMPOSITE PIPING  

DOE Green Energy (OSTI)

The goal of the overall project is to successfully adapt spoolable FRP currently used in the oil industry for use in hydrogen pipelines. The use of FRP materials for hydrogen service will rely on the demonstrated compatibility of these materials for pipeline service environments and operating conditions. The ability of the polymer piping to withstand degradation while in service, and development of the tools and data required for life management are imperative for successful implementation of these materials for hydrogen pipeline. The information and data provided in this report provides the technical basis for the codification for fiber reinforced piping (FRP) for hydrogen service. The DOE has invested in the evaluation of FRP for the delivery for gaseous hydrogen to support the development of a hydrogen infrastructure. The codification plan calls for detailed investigation of the following areas: System design and applicable codes and standards; Service degradation of FRP; Flaw tolerance and flaw detection; Integrity management plan; Leak detection and operational controls evaluation; Repair evaluation. The FRP codification process started with commercially available products that had extensive use in the oil and gas industry. These products have been evaluated to assure that sufficient structural integrity is available for a gaseous hydrogen environment.

Rawls, G.

2012-10-10T23:59:59.000Z

220

Design and economics of a lignite-to-SNG (substitute natural gas) facility using Lurgi gasifiers with in-line conversion of by-product liquids to methane. Topical report (Final), December 1985-November 1986  

SciTech Connect

A first-pass conceptual design and screening cost estimate was prepared for a hypothetical plant to convert lignite to methane using Lurgi dry-bottom gasifiers and employing a black box reactor to convert by-product liquids in the gas phase to methane. Results were compared to those from conventional and modified Lurgi-plant designs. The in-line conversion plant can potentially reduce the cost of gas from a Lurgi plant by about 20%. Due to reduced capital investment, over $200 million could be invested in the reactor before the cost of gas from the in-line conversion plant is as high as that of a Lurgi plant.

Smelser, S.C.

1986-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Heat pipe device and heat pipe fabricating process  

Science Conference Proceedings (OSTI)

An energy saving liquid to liquid heat exchanger for a dishwasher or like device discharging hot waste water comprising a hot water tank for holding the waste water from the dishwasher and having inlet and outlet pipes, a cold water tank for holding the fresh water going to a water heater and having inlet and outlet pipes, the cold water tank disposed on top of the hot water tank, a bundle of heat pipes containing low boiling refrigerant disposed inside of the two tanks so as to extract heat from the hot water tank and give it up to the cold water tank, whereby the temperature of the fresh water leaving the heat exchanger is higher than its entering temperature.

Busch, C.H.

1982-08-10T23:59:59.000Z

222

Magnetic refrigeration apparatus with heat pipes  

DOE Patents (OSTI)

A magnetic refrigerator operating in the 4 to 20 K range utilizes heat pipes to transfer heat to and from the magnetic material at the appropriate points during the material's movement. In one embodiment circular disks of magnetic material can be interleaved with the ends of the heat pipes. In another embodiment a mass of magnetic material reciprocatingly moves between the end of the heat pipe or pipes that transmits heat from the object of cooling to the magnetic material and the end of the heat pipe or pipes that transmits heat from the magnetic material to a heat sink.

Barclay, J.A.; Prenger, F.C. Jr.

1985-10-25T23:59:59.000Z

223

Magnetic refrigeration apparatus with heat pipes  

DOE Patents (OSTI)

A magnetic refrigerator operating in the 4 to 20 K range utilizes heat pipes to transfer heat to and from the magnetic material at the appropriate points during the material's movement. In one embodiment circular disks of magnetic material can be interleaved with the ends of the heat pipes. In another embodiment a mass of magnetic material reciprocatingly moves between the end of the heat pipe of pipes that transmits heat from the object of cooling to the magnetic material and the end of the heat pipe or pipes that transmits heat from the magnetic material to a heat sink.

Barclay, John A. (Los Alamos, NM); Prenger, Jr., F. Coyne (Madison, WI)

1987-01-01T23:59:59.000Z

224

A Novel MagPipe Pipeline transportation system using linear motor drives  

Science Conference Proceedings (OSTI)

A novel capsule pipeline transportation system using linear motor drives, called Magplane MagPipe, is under development with the intention to replace trucks and railways for hauling materials from the mine to the rail head, power plant, or processing plant with reduced operating cost and energy consumption. The initial demonstration of a MagPipe line in Inner Mongolia will be a 500-m-long double-pipe coal transport system with the design transportation capacity of 3 Mega-Mg per year. The pipeline consists of 6-m-long plastic pipe modules with an I-beam suspension system inside the pipe to carry sets of five coupled capsules. The pipe will also contain noncontinuous motor winding modules spaced at 50-m intervals. A set of Halbach-arrayed permanent magnets on the bottom of the capsules interact with the linear motor windings to provide propulsion. The motor is driven by variable frequency drives outside the pipe to control the speed. This paper briefly describes the overall MagPipe pipeline transportation system, including the preliminary conclusions of the linear synchronous motor analysis.

Fang, J.R.; Montgomery, D.B.; Roderick, L. [Magplane Technology Inc., Littleton, MA (United States)

2009-11-15T23:59:59.000Z

225

NETL: News Release - New Carbon Drill Pipe Signals Technical Achievement  

NLE Websites -- All DOE Office Websites (Extended Search)

May 17, 2004 May 17, 2004 New Carbon Drill Pipe Signals Technical Achievement Technology May Benefit American Energy Production WASHINGTON, DC -- The Department of Energy (DOE) announced today the development of a new "composite" drill pipe that is lighter, stronger and more flexible than steel, which could significantly alter the ability to drain substantially more oil and gas from rock than traditional vertical wells. MORE INFO Read about January, 2003 field test Read about October, 2003 field test - "This is another example of the technology breakthroughs in the arena of domestic energy production being carried out by our Office of Fossil Energy," said Secretary of Energy Spencer Abraham. "To reach and recover untapped domestic oil and gas reserves, we must have the ability to

226

Adaptive noise cancellation schemes for magnetic flux leakage signals obtained from gas pipeline inspection  

Science Conference Proceedings (OSTI)

Nondestructive evaluation of the gas pipeline system is most commonly performed using magnetic flux leakage (MFL) techniques. A major segment of this network employs seamless pipes. The data obtained From MFL inspection of seamless pipes is contaminated ...

M. Afzal; R. Polikar; L. Udpa; S. Udpa

2001-05-01T23:59:59.000Z

227

A probe for in situ, remote, detection of defects in buried plastic natural gas pipelines  

Science Conference Proceedings (OSTI)

Several techniques are available to determine the integrity of in situ metal pipeline but very little is available in the literature to determine the integrity of plastic pipelines. Since the decade of the 1970s much of the newly installed gas distribution and transmission lines in the United States are fabricated from polyethylene or other plastic. A probe has been developed to determine the in situ integrity of plastic natural gas pipelines that can be installed on a traversing mechanism (pig) to detect abnormalities in the walls of the plastic natural gas pipeline from the interior. This probe has its own internal power source and can be deployed into existing natural gas supply lines. Utilizing the capacitance parameter, the probe inspects the pipe for flaws and records the data internally which can be retrieved later for analysis.

Mathur, M.P.; Spenik, J.L.; Condon, C.M.; Monazam, E.R.; Fincham, W.L.

2007-12-18T23:59:59.000Z

228

Pipe crawler with extendable legs  

DOE Patents (OSTI)

This invention is comprised of a pipe crawler for moving through a pipe in inchworm fashion having front and rear leg assemblies separated by air cylinders to increase and decrease the spacing. between assemblies. Each leg of the four legs of an assembly is moved between a wall-engaging, extended position and a retracted position by a separate air cylinder. The air cylinders of the leg assemblies are preferably arranged in pairs of oppositely directed cylinders with no pair laying in the same axial plane as another pair. Therefore, the cylinders can be as long as a leg assembly is wide and the crawler can crawl through sections of pipes where the diameter is twice that of other sections. The crawler carries a valving system, a manifold to distribute air supplied by a single umbilical air hose to the various air cylinders in a sequence controlled electrically by a controller. The crawler also utilizes a rolling mechanism, casters in this case, to reduce friction between the crawler and pipe wall thereby further extending the range of the pipe crawler.

Zollinger, W.T.

1991-04-02T23:59:59.000Z

229

Survey of Electric and Gas Rights-of-Way Practitioners: Current Practices and Views of Future Transmission Line Siting Issues  

Science Conference Proceedings (OSTI)

The adequacy of the nation's power grid is a topic of great concern, particularly the extent of new construction and upgrades required over the next decade to meet increasing energy demand. This report compiles the survey responses of energy company professionals associated with the task of developing rights-of-way. Respondents provided information on current industry practices, as well as the social and regulatory environment in which they operate to secure rights-of-way for new transmission lines and u...

2003-12-04T23:59:59.000Z

230

Finite element analysis of contact stress in a full-metallic pipe joint for hydrogen pipelines  

Science Conference Proceedings (OSTI)

Hydrogen gas has been widely recognized as an environmentally clean and renewable energy fuel, and it provides a way to reduce greenhouse gas and air pollution emission. A great deal of effort has been made to develop new techniques in the field of hydrogen ... Keywords: contact stress analyses, finite element model (FEM), hydrogen pipelines, metallic gasket, pipe joint

Nan Bu; Naohiro Ueno; Osamu Fukuda

2010-02-01T23:59:59.000Z

231

REMORA 3: The first instrumented fuel experiment with on-line gas composition measurement by acoustic sensor  

SciTech Connect

With the aim to improve the knowledge of nuclear fuel behaviour, the development of advanced instrumentation used during in-pile experiments in Material Testing Reactor (MTR) is necessary. To obtain data on high Burn-Up MOX fuel performance under transient operating conditions, especially in order to differentiate between the kinetics of fission gas and helium releases and to acquire data on the degradation of the fuel conductivity, a highly instrumented in-pile experiment called REMORA 3 has been conducted by CEA and IES (Southern Electronic Inst. - CNRS - Montpellier 2 Univ.). A rodlet extracted from a fuel rod base irradiated for five cycles in a French EDF commercial PWR has been re-instrumented with a fuel centerline thermocouple, a pressure transducer and an advanced acoustic sensor. This latter, patented by CEA and IES, is 1 used in addition to pressure measurement to determine the composition of the gases located in the free volume and the molar fractions of fission gas and helium. This instrumented fuel rodlet has been re-irradiated in a specific rig, GRIFFONOS, located in the periphery of the OSIRIS experimental reactor core at CEA Saclay. First of all, an important design stage and test phases have been performed before the irradiation in order to optimize the response and the accuracy of the sensors: - To control the influence of the temperature on the acoustic sensor behaviour, a thermal mock-up has been built. - To determine the temperature of the gas located in the acoustic cavity as a function of the coolant temperature, and the average temperature of the gases located in the rodlet free volume as a function of the linear heat rate, thermal calculations have been achieved. The former temperature is necessary to calculate the molar fractions of the gases and the latter is used to calculate the total amount of released gas from the internal rod pressure measurements. - At the end of the instrumented rod manufacturing, specific internal free volume and pressure measurements have been carried out. Preliminary calculations of the REMORA 3 experiments have been performed from these measurements, with the aim to determine free volume evolution as a function of linear heat rate history. - A tracer gas has been added to the filling gas in order to optimize the accuracy of the helium balance at the time of the post irradiation examination. The two phases of the REMORA 3 irradiation have been achieved at the end of 2010 in the OSIRIS reactor. Slight acoustic signal degradation, observed during the test under high neutron and gamma flux, has led to an efficiency optimization of the signal processing. The instrumentation ran smoothly and allowed to reach all the experimental objectives. After non destructive examination performed in the Osiris reactor pool, typically gamma spectrometry and neutron radiography, the instrumented rod and the device have been disassembled. Then the instrumented rod has been transported to the LECA facility in Cadarache Centre for post irradiation examination. The internal pressure and volume of the rodlet as well as precise gas composition measurements will be known after puncturing step performed in a hot cell of this facility. That will allow us to qualify the in-pile measurements and to finalize the data which will be used for the validation of the fuel behaviour computer codes. (authors)

Lambert, T.; Muller, E.; Federici, E. [CEA - Nuclear Energy Div., DEN - Fuel Research Dept. - Cadarache, F-13108 Saint-Paul-Lez-Durance (France); Rosenkrantz, E.; Ferrandis, J. Y. [CNRS - Univ. Montpellier 2, Southern Electronic Inst., UMR 5214, F-34095 Montpellier (France); Tiratay, X.; Silva, V. [CEA, Nuclear Energy Div., DEN, Nuclear Reactors and Facilities Dept., F-91191 Gif Sur Yvette (France); Machard, D. [EDF, SEPTEN, F-69628 Villeurbanne (France); Trillon, G. [AREVA-NP, F-69456 Lyon (France)

2011-07-01T23:59:59.000Z

232

Probability of Failure for Low Alloy Cr-Mo Seam Welded Piping in Fossil Power Plants  

Science Conference Proceedings (OSTI)

Managing longitudinal seam welded piping in fossil fueled power plants is an expensive challenge necessitated by the failures of a few hot reheat and main steam lines. The traditional approach involves inspections during outages that require scaffold erection, insulation removal, surface preparation, and nondestructive evaluation NDE inspection. This report strives to provide utilities with another tool to manage high energy piping systems. It investigates normal distribution of material properties, alon...

2010-12-23T23:59:59.000Z

233

Pipe Rupture Frequencies for Internal Flooding Probabilistic Risk Assessments: Revision 3  

Science Conference Proceedings (OSTI)

This report updates a 2010 EPRI report (1021086) on piping system failure rates for use in probabilistic risk assessments (PRAs) involving internal plant flooding and high-energy line breaks (HELBs) and represents the third revision to this pipe failure rate handbook. These failure rate estimates are intended to satisfy requirements of the American Society of Mechanical Engineers (ASME) and American Nuclear Society (ANS) PRA Standard RA-Sa-2009. The estimates also support an EPRI PRA Scope and ...

2013-04-26T23:59:59.000Z

234

Heat pipe thermal control of irradiation capsules  

SciTech Connect

From 1st international heat pipe conference; Stuttgart, F.R. Germany (15 Oct 1973). The use of heat pipes to control the temperature of irradiation capsules containing fast breeder reactor structural materials is discussed. (TFD)

Deverall, J.E.

1974-04-30T23:59:59.000Z

235

Flat heat pipe design, construction, and analysis  

SciTech Connect

This paper details the design, construction and partial analysis of a low temperature flat heat pipe in order to determine the feasibility of implementing flat heat pipes into thermophotovoltaic (TPV) energy conversion systems.

Voegler, G.; Boughey, B.; Cerza, M.; Lindler, K.W.

1999-08-02T23:59:59.000Z

236

PICEP: Pipe Crack Evaluation Program  

Science Conference Proceedings (OSTI)

We describe a computer program that calculates the crack-opening area, the critical (stable) crack length and the two-phase flow rate through cracks in ductile stainless steel pipes and steam generator tubes. The program is useful in performing leak-before-break calculations in order to demonstrate detectable leak rates prior to a through-wall flaw reaching critical size. Necessary input to the code includes a definition of material properties, loads, thermal-hydraulic conditions, pipe geometry, and crack orientation. User information is provided in the report.

Norris, D.; Okamoto, A.; Chexal, B.; Griesbach, T.

1984-08-01T23:59:59.000Z

237

Exhaust gas reactor  

SciTech Connect

A reactor for the oxidation of unburned and partially burned components in the exhaust gas from an internal combustion engine comprising a chamber which is substantially circular in cross sections perpendicular to its axis, one or more inlet pipes which pass a mixture of exhaust gas and air substantially tangentially into the chamber near to one end thereof, and an outlet pipe near to the other end of the chamber and which is so arranged that exhaust gas leaves the chamber substantially tangentially. The tangential inlet and tangential outlet of gases minimizes energy losses in the gas passing through the reactor. The ratio of the cross-sectional areas of the inlet pipe(s) to reactor chamber is preferably from 1:9 to 25:36, and similar ranges of crosssectional area ratios are preferred for the outlet pipe and chamber. The ratio of the length of the reaction chamber to diameter is preferably from 1:1 to 4:1. The chamber may be cylindrical or divergent from inlet end to outlet end and may be thermally insulated.

Camarsa, M.; Cocchiara, F.; Garcea, G.P.

1981-11-24T23:59:59.000Z

238

Geographic Resource Map of Frozen Pipe Probabilities  

Energy.gov (U.S. Department of Energy (DOE))

Presentation slide details a resource map showing the probability of frozen pipes in the geographic United States.

239

Guide for Piping Stress Analysis and Assessment  

Science Conference Proceedings (OSTI)

This report gives recommendations for piping analysis methods and integration with inspection and operating data to give estimates of risk and remaining life. The scope of the document is as follows: Objectives of piping assessment Selected literature review of assessment practices for piping and other relevant components Failure modes Inspection and operating data Piping analysis: methods and data Risk assessment Integration of analysis, inspection, and operating data for assessments and recommendations...

2010-12-23T23:59:59.000Z

240

Reduce Pumping Costs through Optimum Pipe Sizing  

SciTech Connect

BestPractices Program tip sheet discussing pumping system efficiency by reducing pumping costs through optimum pipe sizing.

2005-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

The Spin-Resolved Atomic Velocity Distribution and 21-cm Line Profile of Dark-Age Gas  

E-Print Network (OSTI)

The 21-cm hyperfine line of atomic hydrogen (HI) is a promising probe of the cosmic dark ages. In past treatments of 21-cm radiation it was assumed the hyperfine level populations of HI could be characterized by a velocity-independent ``spin temperature'' T_s determined by a competition between 21-cm radiative transitions, spin-changing collisions, and (at lower redshifts) Lyman-alpha scattering. However we show here that, if the collisional time is comparable to the radiative time, the spin temperature will depend on atomic velocity, T_s=T_s(v), and one must replace the usual hyperfine level rate equations with a Boltzmann equation describing the spin and velocity dependence of the HI distribution function. We construct here the Boltzmann equation relevant to the cosmic dark ages and solve it using a basis-function method. Accounting for the actual spin-resolved atomic velocity distribution results in up to a 2 per cent suppression of the 21-cm emissivity, and a redshift and angular-projection dependent suppression or enhancement of the linear power spectrum of 21-cm fluctuations of up to 5 per cent. The effect on the 21-cm line profile is more dramatic -- its full-width at half maximum (FWHM) can be enhanced by up to 60 per cent relative to the velocity-independent calculation. We discuss the implications for 21-cm tomography of the dark ages.

Christopher M. Hirata; Kris Sigurdson

2006-05-02T23:59:59.000Z

242

Determination of petroleum pipe scale solubility in simulated lung fluid  

E-Print Network (OSTI)

Naturally occurring radioactive material (NORM) exists in connate waters and, under the right conditions during oil drilling, can plate out on the interior surfaces of oil and gas industry equipment. Once deposited, this material is commonly referred to as ??scale.?? This thesis is concerned with the presence of 226Ra in scale deposited on the inner surfaces of oil drilling pipes and the internal dose consequences of inhalation of that scale once released. In the process of normal operation, barium sulfate scale with a radium component adheres to the inside of downhole tubulars in oil fields. When crude flow is diminished below acceptable operational requirements, the pipe is sent to a descaling operation to be cleaned, most likely by a method known as rattling. The rattling process generates dust. This research investigated the chemical composition of that aerosol and measured the solubility of pipe scale from three oilfield formations. Using standard in-vitro dissolution experimental equipment and methods, pipe scale is introduced into simulated lung fluid over a two-week period. These samples are analyzed using quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS), known for very low detection limits. Analysis reveals virtually no 226Ra present in the lung fluid exposed to pipe scale. Sample measurements were compared against background measurements using Student??s t test, which revealed that nearly all the samples were statistically insignificant in comparison to the lung fluid blanks. This statistical test proves within a 95% confidence interval that there is no 226Ra present in the lung fluid samples. These results indicate that inhaled NORM pipe scale should be classified as Class S and serve to further confirm the extreme insolubility of petroleum pipe scale. For dose calculations, the S classification means that the lung is the main organ of concern. Radium-226 from petroleum pipe scale does not solubilize in the interstitial lung fluid, and does not, therefore, enter the bloodstream via respiratory pathways. Since there is no removal by dissolution, the 500 day biological half-life implied by the S classification is based solely on the mechanical transport of 226Ra out of the lungs by phagocytosis or the mucociliary escalator.

Cezeaux, Jason Roderick

2004-08-01T23:59:59.000Z

243

Virtual Measurement in Pipes, Part 1: Flowing Bottom Hole Pressure Under Multi-Phase Flow and Inclined Wellbore Conditions  

E-Print Network (OSTI)

the utmost importance in maximizing the reservoir energy in naturally flowing and artificial lift wells as the number of variables increases. Many parameters could be involved in these types of problems, such as gas information such as oil, gas and water flow rates, temperature, oil and gas gravity, pipe length, surface

Mohaghegh, Shahab

244

Heat pipe dynamics. Final report, April 30, 1981. [Uses of heat pipe, especially in solar collector  

DOE Green Energy (OSTI)

A heat-pipe flat plate solar collector is constructed like a typical flat plate collector with the exception that individual heat pipes are attached to the collector surface to transfer collected heat via a phase change from collector surface into an attached jacket containing a phase change material. The efficiency of such a collector was measured roughly. Also briefly described are: a heat-pipe heat exchanger, heat-pipe heat exchanger freeze proofing, heat-pipe attic ventilation, transfer of light bulb heat via a heat pipe to heat water, heat recovery via heat pipe, cooling of oil in engines and transmissions via heat pipe, a tracking reflector, automatic sun tracker, single-stroke vacuum pump for heat-pipe manufacture, and heat pipe heat transfer from rock bed. (LEW)

Norman, R.M. Sr.

1981-01-01T23:59:59.000Z

245

Structural Assessment of Small Bore Feeder Piping  

E-Print Network (OSTI)

Frasheri MIE491 - Capstone Team 9 March 2012 Client: W. Reinhardt Industry Partner: Candu Energy Inc. Supervisor: A. N. Sinclair CASE ONE CANDU REACTORS HAVE 380+ SMALL BORE FEEDER PIPES. THE PIPES PIPES AND VALIDATE COMPUTATIONAL METHODS COMPARED TO FULL SCALE TESTS TO FAILURE. THE CLIENT CANDU

246

A DOZEN NEW GALAXIES CAUGHT IN THE ACT: GAS STRIPPING AND EXTENDED EMISSION LINE REGIONS IN THE COMA CLUSTER  

Science Conference Proceedings (OSTI)

We present images of extended H{alpha} clouds associated with 14 member galaxies in the Coma cluster obtained from deep narrowband imaging observations with the Suprime-Cam at the Subaru Telescope. The parent galaxies of the extended H{alpha} clouds are distributed farther than 0.2 Mpc from the peak of the X-ray emission of the cluster. Most of the galaxies are bluer than g - r {approx} 0.5 and they account for 57% of the blue (g - r < 0.5) bright (r < 17.8 mag) galaxies in the central region of the Coma cluster. They reside near the red- and blueshifted edges of the radial velocity distribution of Coma cluster member galaxies. Our findings suggest that most of the parent galaxies were recently captured by the Coma cluster potential and are now infalling toward the cluster center with their disk gas being stripped off and producing the observed H{alpha} clouds.

Yagi, Masafumi; Komiyama, Yutaka; Kashikawa, Nobunari [Optical and Infrared Astronomy Division, National Astronomical Observatory of Japan, 2-21-1, Osawa, Mitaka, Tokyo 181-8588 (Japan); Yoshida, Michitoshi [Hiroshima Astrophysical Science Center, Hiroshima University, 1-3-1, Kagamiyama, Higashi-Hiroshima, Hiroshima 739-8526 (Japan); Furusawa, Hisanori [Astronomy Data Center, National Astronomical Observatory of Japan, 2-21-1, Osawa, Mitaka, Tokyo 181-8588 (Japan); Okamura, Sadanori [Department of Astronomy, School of Science, University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Graham, Alister W. [Centre for Astrophysics and Supercomputing, Swinburne University of Technology, Hawthorn, Victoria 3122 (Australia); Miller, Neal A. [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Carter, David [Astronomical Research Institute, Liverpool John Moores University, Twelve Quays House, Egerton Warf, Birkenhead CH41 1LD (United Kingdom); Mobasher, Bahram [Department of Physics and Astronomy, University of California, Riverside, CA 92521 (United States); Jogee, Shardha, E-mail: YAGI.Masafumi@nao.ac.j [Department of Astronomy, University of Texas at Austin, 1 University Station C1400, Austin, TX 78712 (United States)

2010-12-15T23:59:59.000Z

247

Determination of filter-cake thicknesses from on-line flow measurements and gas/particle transport modeling  

SciTech Connect

The use of cylindrical candle filters to remove fine ({approx}0.005 mm) particles from hot ({approx}500- 900{degrees}C) gas streams currently is being developed for applications in advanced pressurized fluidized bed combustion (PFBC) and integrated gasification combined cycle (IGCC) technologies. Successfully deployed with hot-gas filtration, PFBC and IGCC technologies will allow the conversion of coal to electrical energy by direct passage of the filtered gases into non-ruggedized turbines and thus provide substantially greater conversion efficiencies with reduced environmental impacts. In the usual approach, one or more clusters of candle filters are suspended from a tubesheet in a pressurized (P {approx_lt}1 MPa) vessel into which hot gases and suspended particles enter, the gases pass through the walls of the cylindrical filters, and the filtered particles form a cake on the outside of each filter. The cake is then removed periodically by a backpulse of compressed air from inside the filter, which passes through the filter wall and filter cake. In various development or demonstration systems the thickness of the filter cake has proved to be an important, but unknown, process parameter. This paper describes a physical model for cake and pressure buildups between cleaning backpulses, and for longer term buildups of the ``baseline`` pressure drop, as caused by incomplete filter cleaning and/or re-entrainment. When combined with operating data and laboratory measurements of the cake porosity, the model may be used to calculate the (average) filter permeability, the filter-cake thickness and permeability, and the fraction of filter-cake left on the filter by the cleaning backpulse or re-entrained after the backpulse. When used for a variety of operating conditions (e.g., different coals, sorbents, temperatures, etc.), the model eventually may provide useful information on how the filter-cake properties depend on the various operating parameters.

Smith, D.H.; Powell, V. [USDOE Morgantown Energy Technology Center, WV (United States); Ibrahim, E. [Oak Ridge Inst. for Science and Education, TN (United States); Ferer, M. [West Virginia Univ., Morgantown, WV (United States). Dept. of Physics; Ahmadi, G. [National Research Council, Washington, DC (United States)

1996-12-31T23:59:59.000Z

248

Analysis of Cracked Pipe Weldments  

Science Conference Proceedings (OSTI)

EPRI estimation formulas for predicting loads necessary for crack initiation and instability can facilitate leak-before-break analysis of cracked nuclear piping. Finite-element calculations carried out in this study verified the accuracy of these formulas for analyzing through-the-wall cracks in bimetallic weldments.

1987-02-01T23:59:59.000Z

249

On0Line Fuel Failure Monitor for Fuel Testing and Monitoring of Gas Cooled Very High Temperature Reactor  

Science Conference Proceedings (OSTI)

IVery High Temperature Reactors (VHTR) utilize the TRISO microsphere as the fundamental fuel unit in the core. The TRISO microsphere (~ 1- mm diameter) is composed of a UO2 kernel surrounded by a porous pyrolytic graphite buffer, an inner pyrolytic graphite layer, a silicon carbide (SiC) coating, and an outer pyrolytic graphite layer. The U-235 enrichment of the fuel is expected to range from 4% – 10% (higher enrichments are also being considered). The layer/coating system that surrounds the UO2 kernel acts as the containment and main barrier against the environmental release of radioactivity. To understand better the behavior of this fuel under in-core conditions (e.g., high temperature, intense fast neutron flux, etc.), the US Department of Energy (DOE) is launching a fuel testing program that will take place at the Advanced Test Reactor (ATR) located at Idaho National Laboratory (INL). During this project North Carolina State University (NCSU) researchers will collaborate with INL staff for establishing an optimized system for fuel monitoring for the ATR tests. In addition, it is expected that the developed system and methods will be of general use for fuel failure monitoring in gas cooled VHTRs.

Ayman I. Hawari; Mohamed A. Bourham

2010-04-22T23:59:59.000Z

250

Evaluation of cracking in the 241-AZ tank farm ventilation line at the Hanford Site  

Science Conference Proceedings (OSTI)

In the period from April to October of 1988, a series of welding operations on the outside of the AZ Tank Farm ventilation line piping at the Hanford Site produced unexpected and repeated cracking of the austenitic stainless steel base metal and of a seam weld in the pipe. The ventilation line is fabricated from type 304L stainless steel pipe of 24 inch diameter and 0.25 inch wall thickness. The pipe was wrapped in polyethylene bubble wrap and buried approximately 12 feet below grade. Except for the time period between 1980 and 1987, impressed current cathodic protection has been applied to the pipe since its installation in 1974. The paper describes the history of the cracking of the pipe, the probable cracking mechanisms, and the recommended future action for repair/replacement of the pipe.

ANANTATMULA, R.P.

1999-10-20T23:59:59.000Z

251

Fast okay urged for Alaska line prebuild funding  

Science Conference Proceedings (OSTI)

Foothills Pipelines (Yukon) Ltd. has asked the Canada National Energy Board (NEB) to approve its financing plans for the prebuilt sections of the Alaska Highway gas pipeline along with a number of other conditions, which include approval of additional gas exports for its affiliate company, Pan-Alberta Gas Ltd.; accelerated depreciation rates for prebuilt facilities in Alberta and British Columbia; a minimum 17.5% flat rate of return on equity; and diversion of gas exports approved for two other companies to the prebuilt facilities when completed. NEB's decision is expected March 11, 1980. Trans Mountain Pipe Line Co. Ltd. has informed NEB that it will proceed with its application to build a pipeline from Low Point, Wash., to Edmonton, Alberta, to transport Alaska crude oil, and also to build a tanker port in Washington State. Gas deliveries from Alberta to eastern Canada and the US have returned to normal seasonal volume following the explosion February 26, 1980 in Trans-Canada Pipeline Ltd.'s 85,000 hp compressor station. Repair costs, cause of the explosion, and modifications of the safety procedures remain to be determined.

Not Available

1980-03-10T23:59:59.000Z

252

Potential of the heat pipe in coal gasification processes  

SciTech Connect

The declining production of natural gas in the United States has provided great impetus to the development of economcal methods of producing methane from coal. Coal gasification systems share in common a need for highly efficient heat transfer and energy recovery methods in order to maximize the coal-methane conversion efficiency. Characteristics of heat pipe heat transfer units that offer potential for increasing conversion efficiency and/or reducing production costs include: (1) complete physical separation of process streams, (2) capability of handling more than two process streams in a single unit, (3) heat removal at near-constant temperature, (4) high heat recovery efficiency, (5) low operating cost-with no requirement for auxiliary power, and (6) relative ease of cleaning. Design concepts incorporating heat pipes into indirect coal gasification units, methanators, and energy recovery units are presented and technological impediments that must be surmounted in the successful development of these units are discussed.

Ranken, W.A.

1976-01-01T23:59:59.000Z

253

Benchmark Gamma Spectroscopy Measurements of Uranium Hexafluoride in Aluminmum Pipe with a Sodium Iodide Detector  

SciTech Connect

The expected increased demand in fuel for nuclear power plants, combined with the fact that a significant portion of the current supply from the blend down of weapons-source material will soon be coming to an end, has led to the need for new sources of enriched uranium for nuclear fuel. As a result, a number of countries have announced plans, or are currently building, gaseous centrifuge enrichment plants (GCEPs) to supply this material. GCEPs have the potential to produce uranium at enrichments above the level necessary for nuclear fuel purposes-enrichments that make the uranium potentially usable for nuclear weapons. As a result, there is a critical need to monitor these facilities to ensure that nuclear material is not inappropriately enriched or diverted for unintended use. Significant advances have been made in instrument capability since the current International Atomic Energy Agency (IAEA) monitoring methods were developed. In numerous cases, advances have been made in other fields that have the potential, with modest development, to be applied in safeguards applications at enrichment facilities. A particular example of one of these advances is the flow and enrichment monitor (FEMO). (See Gunning, J. E. et al., 'FEMO: A Flow and Enrichment Monitor for Verifying Compliance with International Safeguards Requirements at a Gas Centrifuge Enrichment Facility,' Proceedings of the 8th International Conference on Facility Operations - Safeguards Interface. Portland, Oregon, March 30-April 4th, 2008.) The FEMO is a conceptual instrument capable of continuously measuring, unattended, the enrichment and mass flow of {sup 235}U in pipes at a GCEP, and consequently increase the probability that the potential production of HEU and/or diversion of fissile material will be detected. The FEMO requires no piping penetrations and can be installed on pipes containing the flow of uranium hexafluoride (UF{sub 6}) at a GCEP. This FEMO consists of separate parts, a flow monitor (FM) and an enrichment monitor (EM). Development of the FM is primarily the responsibility of Oak Ridge National Laboratory, and development of the EM is primarily the responsibility of Los Alamos National Laboratory. The FM will measure {sup 235}U mass flow rate by combining information from measuring the UF{sub 6} volumetric flow rate and the {sup 235}U density. The UF{sub 6} flow rate will be measured using characteristics of the process pumps used in product and tail UF{sub 6} header process lines of many GCEPs, and the {sup 235}U density will be measured using commercially available sodium iodide (NaI) gamma ray scintillation detectors. This report describes the calibration of the portion of the FM that measures the {sup 235}U density. Research has been performed to define a methodology and collect data necessary to perform this calibration without the need for plant declarations. The {sup 235}U density detector is a commercially available system (GammaRad made by Amptek, www.amptek.com) that contains the NaI crystal, photomultiplier tube, signal conditioning electronics, and a multichannel analyzer (MCA). Measurements were made with the detector system installed near four {sup 235}U sources. Two of the sources were made of solid uranium, and the other two were in the form of UF{sub 6} gas in aluminum piping. One of the UF{sub 6} gas sources was located at ORNL and the other at LANL. The ORNL source consisted of two pipe sections (schedule 40 aluminum pipe of 4-inch and 8-inch outside diameter) with 5.36% {sup 235}U enrichment, and the LANL source was a 4-inch schedule 40 aluminum pipe with 3.3% {sup 235}U enrichment. The configurations of the detector on these test sources, as well as on long straight pipe configurations expected to exist at GCEPs, were modeled using the computer code MCNP. The results of the MCNP calculations were used to define geometric correction factors between the test source and the GCEP application. Using these geometric correction factors, the experimental 186 keV counts in the test geometry were extrapolated to the expected GCEP ge

March-Leuba, Jose A [ORNL; Uckan, Taner [ORNL; Gunning, John E [ORNL; Brukiewa, Patrick D [ORNL; Upadhyaya, Belle R [ORNL; Revis, Stephen M [ORNL

2010-01-01T23:59:59.000Z

254

NON-DESTRUCTIVE TESTING METHODS FOR GEOTHERMAL PIPING.  

DOE Green Energy (OSTI)

Non-destructive testing is a key component of optimized plant inspection and maintenance programs. Risk based inspection, condition based maintenance and reliability centered maintenance systems all require detection, location and sizing of defects or flaws by non-destructive methods. Internal damage of geothermal piping by corrosion and erosion-corrosion is an ongoing problem requiring inspection and subsequent maintenance decisions to ensure safe and reliable performance. Conventional manual ultrasonic testing to determine remaining wall thickness has major limitations, particularly when damage is of a random and localized nature. Therefore, it is necessary to explore alternative non-destructive methods that offer potential benefits in terms of accurate quantification of size, shape and location of damage, probability of detection, ability to use on-line over long ranges, and economics. A review of non-destructive methods and their applicability to geothermal piping was performed. Based on this, ongoing research will concentrate on long range guided wave and dynamic methods.

BERNDT,M.L.

2001-03-23T23:59:59.000Z

255

Gas Utilities (New York)  

Energy.gov (U.S. Department of Energy (DOE))

This chapter regulates natural gas utilities in the State of New York, and describes standards and procedures for gas meters and accessories, gas quality, line and main extensions, transmission and...

256

Heat-Pipe Development for Advanced Energy Transport Concepts Final Report Covering the Period January 1999 through September 2001  

SciTech Connect

This report summarizes work in the Heat-pipe Technology Development for the Advanced Energy Transport Concepts program for the period January 1999 through September 2001. A gas-loaded molybdenum-sodium heat pipe was built to demonstrate the active pressure-control principle applied to a refractory metal heat pipe. Other work during the period included the development of processing procedures for and fabrication and testing of three types of sodium heat pipes using Haynes 230, MA 754, and MA 956 wall materials to assess the compatibility of these materials with sodium. Also during this period, tests were executed to measure the response of a sodium heat pipe to the penetration of water.

R.S.Reid; J.F.Sena; A.L.Martinez

2002-10-01T23:59:59.000Z

257

Heat-Pipe Wick Characterization  

SciTech Connect

The development of liquid metal heat-pipes for use in solar powered Stirling engines has led to an in-depth analysis of heat-pipe wick properties. To model the flow of liquid sodium through the wick its two-phase permeability measurement is of interest. The permeability will be measured by constructing a test cell made up of a wick sample sintered to a manifold. Measuring the volumetric flow rate through the wick will allow for a determination of the wick's permeability as a function of pressure. Currently, simple estimates of permeability as a function of vapor fraction of a porous media are being used as a model to calculate the two-phase permeability. The above mentioned experiment will be used to test the existing formulas validity. The plan is to make use of a known procedure for testing permeability and apply those techniques to a felt-metal wick. The results will be used to verify and/or modify the two-phase permeability estimates. With the increasing desire to replace directly illuminated engines with the much more efficient heat-pipe apparatus it is inherently clear that the usefulness of known wick properties will make wick permeability design a simpler process.

JONES II,JERRY LEE

2000-08-15T23:59:59.000Z

258

Heat-Pipe Wick Characterization  

DOE Green Energy (OSTI)

The development of liquid metal heat-pipes for use in solar powered Stirling engines has led to an in-depth analysis of heat-pipe wick properties. To model the flow of liquid sodium through the wick its two-phase permeability measurement is of interest. The permeability will be measured by constructing a test cell made up of a wick sample sintered to a manifold. Measuring the volumetric flow rate through the wick will allow for a determination of the wick's permeability as a function of pressure. Currently, simple estimates of permeability as a function of vapor fraction of a porous media are being used as a model to calculate the two-phase permeability. The above mentioned experiment will be used to test the existing formulas validity. The plan is to make use of a known procedure for testing permeability and apply those techniques to a felt-metal wick. The results will be used to verify and/or modify the two-phase permeability estimates. With the increasing desire to replace directly illuminated engines with the much more efficient heat-pipe apparatus it is inherently clear that the usefulness of known wick properties will make wick permeability design a simpler process.

JONES II,JERRY LEE

2000-08-15T23:59:59.000Z

259

Middle East future line plans muddled following Gulf War  

Science Conference Proceedings (OSTI)

This paper reports that the recent Gulf War has left the middle East in an awkward situation on current and future pipe line projects. Much of Kuwait's production capacity was destroyed and its ability to regain its previous position as an oil producer in the Middle East in the near term is questionable. Iraq's production remains severely curtailed by international agreement. Saudi Arabia and the other Middle Eastern states continue to produce at the higher than normal levels instigated in the early days of the crisis. The continuing efforts to bring the Kuwait oilfields under control, coupled with ongoing excessive production by some Middle eastern countries and the world response to Sadam Hussein's questionable intentions leave the Middle East pipe line construction picture muddled. The war forestalled pipe line projects in Kuwait and Iraq and many of the planned projects now are questionable. In other areas of the Middle East, the war may have firmed tentative plans for pipe line construction.

Not Available

1991-11-01T23:59:59.000Z

260

Line Pipe Needs, Performance and Mill Steel Processing to Meet ...  

Science Conference Proceedings (OSTI)

... to Meet Demands for Offshore Deepwater Developments in the Gulf-of-Mexico ... for drilling risers, tension leg platform tendons, production gathering systems ...

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Product Classification  

Science Conference Proceedings (OSTI)

Table 1 Major types and uses of pipe...or residential water steam, oil, or gas transmission; distribution or service lines; structural uses Special Conduit, piling, pipe for nipples, and other Line Oil- or gas-transmission pipe, water-main pipe Oil country tubular goods Drill pipe, casing, tubing Water well Drive pipe, driven-well pipe,...

262

Off gas film cooler cleaner  

DOE Patents (OSTI)

An apparatus is described for cleaning depositions of particulate matter from the inside of tubular piping while the piping is in use. The apparatus is remotely controlled in order to operate in hazardous environments. A housing containing brush and shaft assemblies is mounted on top of the tubular piping. Pneumatic cylinders provide linear motion. A roller nut bearing provides rotary motion. The combined motion causes the brush assembly to rotate as it travels along the tube dislodging particulate matter. The main application for this invention is to clean the off gas cooler of a radioactive waste vitrification unit.

Dhingra, H.S.; Koch, W.C.; Burns, D.C.

1995-12-31T23:59:59.000Z

263

Heat pipe theory and practice: a sourcebook  

SciTech Connect

An introduction to heat pipe operating principles, types, and applications followed by a comprehensive treatment of heat pipe theory, design, and manufacture are presented. The organization of heat pipe theory provides parallel treatment of the fundamental laws of thermodynamics, heat transfer, fluid mechanics, and materials science during heat pipe analysis. For the problem-solving convenience of practicing engineers, design procedures are developed summarizing theoretical information. Methods of summarizing voluminous research information are presented in detail. Current practices in the manufacture of heat pipes are described. Current and potential applications of the heat pipe to energy systems discussed are: heat exchangers, heat recovery for HVAC systems, residential buildings, industrial processes, gasification plants, and thermal storage subsystems.

Chi, S.W.

1976-01-01T23:59:59.000Z

264

Piping inspection carriage having axially displaceable sensor  

DOE Patents (OSTI)

A pipe inspection instrument carriage is described for use with a pipe crawler for performing internal inspections of piping surfaces. The carriage has a front leg assembly, a rear leg assembly and a central support connecting the two assemblies and for mounting an instrument arm having inspection instruments. The instrument arm has a Y-arm mounted distally thereon for axially aligning the inspection instrumentation and a mounting block, a linear actuator and axial movement arm for extending the inspection instruments radially outward to operably position the inspection instruments on the piping interior. Also, the carriage has a rotation motor and gear assembly for rotating the central support and the front leg assembly with respect to the rear leg assembly so that the inspection instruments azimuthally scan the piping interior. The instrument carriage allows performance of all piping inspection operations with a minimum of moving parts, thus decreasing the likelihood of performance failure. 4 figures.

Zollinger, W.T.; Treanor, R.C.

1994-12-06T23:59:59.000Z

265

Buried Pipe Guided Wave Examination Reference Document  

Science Conference Proceedings (OSTI)

As the nuclear power fleet has aged, the industry has increased its focus on the integrity of buried piping assets. This is due to recent leaks resulting in unscheduled repair outages and release of tritium into the ground water. The Electric Power Research Institute (EPRI) has responded to the emergent issue by developing a buried pipe program, which many plants have implemented or are implementing, as well as projects to assess and develop inspection and repair technologies. There are many buried pipes...

2009-10-29T23:59:59.000Z

266

Downhole pipe selection for acoustic telemetry  

DOE Patents (OSTI)

A system is described for transmitting signals along a downhole string including a plurality of serially connected tubular pipes such as drill or production pipes, a transmitter for transmitting a signal along the string and a receiver for receiving the signal placed along the string at a location spaced from said transmitting means, wherein the pipes between the transmitter and the receiver are ordered according to length of tube to minimize loss of signal from said transmitter to said receiver. 7 figs.

Drumheller, D.S.

1995-12-19T23:59:59.000Z

267

Downhole pipe selection for acoustic telemetry  

DOE Patents (OSTI)

A system for transmitting signals along a downhole string including a plurality of serially connected tubular pipes such as drill or production pipes, a transmitter for transmitting a signal along the string and a receiver for receiving the signal placed along the string at a location spaced from said transmitting means, wherein the pipes between the transmitter and the receiver are ordered according to length of tube to minimize loss of signal from said transmitter to said receiver.

Drumheller, Douglas S. (Cedar Crest, NM)

1995-01-01T23:59:59.000Z

268

Development of a cryogenic heat pipe  

SciTech Connect

Heat pipe operating characteristics can be used to advantage in cryogenic systems. Diode operation of the heat pipe, the ability to conduct heat in one direction only, is useful in protecting the heat load if the heat sink temperature rises above the load temperature. Because of this, the heat pipe can be made to act as a thermal switch. A screened-wick, inverted-artery, cryogenic heat pipe was designed, fabricated, and tested. The tests were first conducted with hydrogen and then with oxygen as the working fluid. Heat pipe performance limits were measured as a function of operating temperature, and startup from both the supercritical and the frozen state was demonstrated. The heat pipe was designed to operate as a thermal diode, and transient tests were used to determine the turndown ratio. The heat pipe test results were correlated with the Los Alamos heat pipe computer code and good agreement was obtained between the predicted and measured performance. The heat pipe was developed for spacecraft sensor cooling applications. Test results show significant performance advantages over solid conductors.

Prenger, F.C.; Stewart, W.F.; Runyan, J.E.

1993-08-01T23:59:59.000Z

269

Building Energy Software Tools Directory: Pipe Designer  

NLE Websites -- All DOE Office Websites (Extended Search)

leg in the system. You can also analyze hybrid systems consisting of new and existing piping and reverse-return layouts The familiar, intuitive Windows user interface will...

270

NETL: News Release - Intelligent Pipe Technology Communicates...  

NLE Websites -- All DOE Office Websites (Extended Search)

May 4, 2005 Intelligent Pipe Technology Communicates Faster than Internet Technology on Verge of Commercialization Provides Fast, Reliable Communication During Downhole Drilling...

271

Building Energy Software Tools Directory: Pipe Designer  

NLE Websites -- All DOE Office Websites (Extended Search)

and closed systems using virtually any fluid with known viscosity and specific gravity. Enter coil flow rates and pressure drops along with pipe lengths -- the program will...

272

Dismantling techniques for reactor steel piping  

SciTech Connect

Two cutting techniques have been developed for dismantling the pipes connected to the Japan Power Demonstration Reactor (JPDR) pressure vessel. They are the rotary disk knife cutting system for dismantling relatively large pipes, such as the primary cooling system, and the shaped explosive cutting systems for cutting relatively small pipes in air or water. Basic cutting tests were performed to determine the optimum characteristics of the cutting systems and to conduct a safety evaluation by studying the effects of blasting on surrounding areas. Mock-up tests confirmed the applicability of the newly developed dismantling systems for JPDR dismantlement by successfully cutting test pipes with these systems.

Yanagihara, S.; Hiraga, F.; Nakamura, H. (Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan))

1989-08-01T23:59:59.000Z

273

Aircraft Thermal Management Using Loop Heat Pipes.  

E-Print Network (OSTI)

??The objective of this thesis was to determine the feasibility of using loop heat pipes to dissipate waste heat from power electronics to the skin… (more)

Fleming, Andrew J.

2009-01-01T23:59:59.000Z

274

Experimental Investigation of Bendable Heat Pipes.  

E-Print Network (OSTI)

??Heat pipes are highly conductive heat transfer devices. They use the latent heat of the working fluid for efficient heat transfer over a very small… (more)

ODHEKAR, DHANANJAY

2005-01-01T23:59:59.000Z

275

Entirely passive heat-pipe apparatus capable of operating against gravity  

DOE Patents (OSTI)

The disclosure is directed to an entirely passive heat pipe apparatus capable of operating against gravity for vertical distances in the order of 3 to 7 and more. A return conduit into which an inert gas is introduced is used to lower the specific density of the working fluid so that it may be returned a greater vertical distance from condenser to evaporator.

Koenig, D.R.

1981-02-11T23:59:59.000Z

276

Flow of fracturing foams in vertical, horizontal and inclined pipes  

E-Print Network (OSTI)

Foams are complex mixtures of a gas and a liquid, with the latter being the continuous phase. The rheological properties of foams are strongly influenced by parameters like temperature, absolute pressure, foam quality, texture, foam-channel wall effects, liquid phase properties, and type and concentration of surfactant. The high solids carrying capacity, the minimum amount of fluid placed in the formation, and the excellent fluid recovery after treatment are some of the advantages that foam fluids present when used during fracturing operations. This thesis is a study of foam flow in pipes, the pressure calculations, the study of rheological properties and their evaluation. The objectives of this research are to: 1. Compare various rheological models representing foams. 2. Develop an algorithm that finds the rheological parameters for the different models at different pressures in the pipe. 3. Provide an engineer with a method that predicts pressure at one end, if pressure at the other end is known, given the rheological parameters of the fluid, the diameter of the pipe and the inlet stream properties. 4. Provide a spreadsheet program for different fluid models that calculates pressures in an inclined, vertical or horizontal pipe. 5. Validate the programs. General curve fitting techniques are used to fit different models: namely, power law, Bingham plastic and Herschel Bulkley models to shear stress vs. shear rate data. The trend of the power law and Bingham plastic rheological parameters with respect to quality is observed. A method to estimate the rheological parameters at different pressures along the pipe using regression methods is developed. Spreadsheet programs for power law Bingham plastic and volume equalized power law model have been developed, which calculate pressures in inclined, horizontal and vertical pipes. The methods for the power law and Bingham plastic fluids are iterative methods. The volume equalized power law program adopts the volume equalized principle, which uses mechanical energy balance with frictional losses calculated from a rheological model. The mechanical energy balance is integrated to obtain a non-linear equation containing the unknown pressure.

Krindinti, Kshipraprasad H

2002-01-01T23:59:59.000Z

277

Apparatus for screwing pipes together  

Science Conference Proceedings (OSTI)

A power tongs for threadedly connecting together pipes which are to constitute casings for boreholes has a platform for a reciprocable slide which supports a power-driven threading clamp and a counter device. The clamp and the counter device are connected to each other by several level compensating hydraulic cylinders each of which is movable horizontally within limits relative to the slide against the opposition of resilient support elements. The upper end portions of the cylinders are connected to a holding plate for the clamp.

Reinholdt, B.; Bock, H. -Ch.

1985-01-08T23:59:59.000Z

278

Capacity Testing of Cured-in-Place Pipe  

Science Conference Proceedings (OSTI)

This report describes results of capacity testing of cured-in-place pipe (CIPP). Degradation of buried piping is a major issue facing nuclear power plant owners, and many plants will require repair or replacement of existing carbon steel piping components. Relining corroded steel pipe with cured-in-place pipe is an attractive and cost-effective alternative to replacing in-ground pipe.

2009-12-10T23:59:59.000Z

279

Mexssub responds to shallow pipe corrosion  

Science Conference Proceedings (OSTI)

Mexssub recently came to the aid of the Mexican state-owned oil company Pemex to repair corrosion problems on a 36-inch sour gas pipeline located in the Atasta-Ciudad Pemex corridor. Mexssub began development of a sleeve system in 1982 in an effort to develop solutions for risers located in the Campeche Bay area. High operating temperatures of these risers was causing failures of the protective coating and accelerated corrosion to the riser at the splash zone. The sleeve system and flexible habitat developed by Mexssub during this research program allowed the repair of these risers in situ and without suspending production. The sleeve system developed by Mexssub is a welded oversize sleeve with a specially formulated epoxy resin injected into the annular space. The epoxy resin completely integrates the sleeve and the pipe, providing structural reinforcement. This technology was demonstrated to Pemex at the Mexssub testing facility in Lerma, Mexico in 1986. In 1987 the Mexssub Sleeve System was approved by the Mexican Petroleum Institute and actual field repairs were initiated. To date, Mexssub has made in excess of 72 repairs in situ without suspending production on risers up to 36-inch diameter. Additionally, the sleeve system has been installed on 50 new risers prior to their installation in the field.

Cajiga, A.; Perez, V.

1996-04-01T23:59:59.000Z

280

Analysis of Pipe Supports with a Trunnion Welded to the Main Piping Run  

Science Conference Proceedings (OSTI)

One configuration of pipe support that is gaining popularity, particularly on main steam and hot reheat high-energy piping, is the trunnion. In a trunnion support system, load is transferred from the main pipe to a hanger system through trunnions welded to the main pipe run. Welded trunnions are used in a variety of support configurations, and, in several cases, the support frame around the trunnion would have to be dismantled to permit inspection of the pipe-to-trunnion weld. In other ...

2013-10-22T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Heat transfer. [heat transfer roller employing a heat pipe  

SciTech Connect

A heat transfer roller embodying a heat pipe is disclosed. The heat pipe is mounted on a shaft, and the shaft is adapted for rotation on its axis.

Sarcia, D.S.

1978-05-23T23:59:59.000Z

282

Statistical estimation of water distribution system pipe break risk.  

E-Print Network (OSTI)

??The deterioration of pipes in urban water distribution systems is of concern to water utilities throughout the world. This deterioration generally leads to pipe breaks… (more)

Yamijala, Shridhar

2009-01-01T23:59:59.000Z

283

Heat pipe with embedded wick structure  

SciTech Connect

A heat pipe has an embedded wick structure that maximizes capillary pumping capability. Heat from attached devices such as integrated circuits evaporates working fluid in the heat pipe. The vapor cools and condenses on a heat dissipation surface. The condensate collects in the wick structure, where capillary pumping returns the fluid to high heat areas.

Adkins, Douglas Ray (Albuquerque, NM); Shen, David S. (Albuquerque, NM); Tuck, Melanie R. (Albuquerque, NM); Palmer, David W. (Albuquerque, NM); Grafe, V. Gerald (Corrales, NM)

1999-01-01T23:59:59.000Z

284

Heat pipe with embedded wick structure  

DOE Patents (OSTI)

A heat pipe has an embedded wick structure that maximizes capillary pumping capability. Heat from attached devices such as integrated circuits evaporates working fluid in the heat pipe. The vapor cools and condenses on a heat dissipation surface. The condensate collects in the wick structure, where capillary pumping returns the fluid to high heat areas. 7 figs.

Adkins, D.R.; Shen, D.S.; Tuck, M.R.; Palmer, D.W.; Grafe, V.G.

1998-06-23T23:59:59.000Z

285

Heat pipe with embedded wick structure  

SciTech Connect

A heat pipe has an embedded wick structure that maximizes capillary pumping capability. Heat from attached devices such as integrated circuits evaporates working fluid in the heat pipe. The vapor cools and condenses on a heat dissipation surface. The condensate collects in the wick structure, where capillary pumping returns the fluid to high heat areas.

Adkins, Douglas Ray (Albuquerque, NM); Shen, David S. (Albuquerque, NM); Tuck, Melanie R. (Albuquerque, NM); Palmer, David W. (Albuquerque, NM); Grafe, V. Gerald (Corrales, NM)

1998-01-01T23:59:59.000Z

286

Geothermal drill pipe corrosion test plan  

DOE Green Energy (OSTI)

Plans are presented for conducting a field test of drill pipe corrosion, comparing air and nitrogen as drilling fluids. This test will provide data for evaluating the potential of reducing geothermal well drilling costs by extending drill pipe life and reducing corrosion control costs. The 10-day test will take place during fall 1980 at the Baca Location in Sandoval County, New Mexico.

Caskey, B.C.; Copass, K.S.

1980-12-01T23:59:59.000Z

287

Hydrogen Piping Experience in Chevron Refining  

NLE Websites -- All DOE Office Websites (Extended Search)

Piping Piping Experience in Chevron Refining Ned Niccolls Materials Engineer Chevron Energy Technology Company Hydrogen Pipeline Working Group Workshop August 30-31, 2005 Outline 2 Overall perspectives from long term use of hydrogen piping in refining. Piping specifications and practices. The (few) problem areas. Related industry work: American Petroleum Institute corrosion and materials work on high temperature hydrogen attack. Overall Perspectives 3 Few problems with hydrogen piping operating at ambient to at least 800F and pressures up to at least 3000psia as long as we stay within well- defined limits H2S contamination presents many more problems, beyond the scope of this talk We will note a couple of specific vulnerabilities Refining tracks materials performance in

288

Heat pipe nuclear reactor for space power  

SciTech Connect

A heat-pipe cooled nuclear reactor has been designed to provide 3.2 MW(t) to an out-of-core thermionic conversion system. The reactor is a fast reactor designed to operate at a nominal heat pipe temperature of 1675/sup 0/K. Each reactor fuel element consists of a hexagonal molybdenum block which is bonded along its axis to one end of a molybdenum, lithium vapor, heat pipe. The block is perforated with an array of longitudinal holes which are loaded with UO/sub 2/ pellets. The heat pipe transfers heat directly to a string of six thermionic converters which are bonded along the other end of the heat pipe. An assembly of 90 such fuel elements forms a hexagonal core. The core is surrounded by a thermal radiation shield, a thin thermal neutron absorber and a BeO reflector containing boron loaded control drums.

Koenig, D.R.

1976-01-01T23:59:59.000Z

289

Rotating heat pipe for air-conditioning  

SciTech Connect

A unique rotary hermetic heat pipe is disclosed for transferring heat from an external source to an external heat sink. The heat pipe has a tapered condensing surface which is curved preferably to provide uniform pumping acceleration, the heat pipe being rotated at a velocity such that the component of centrifugal acceleration in an axial direction parallel to the tapered surface is greater than lG and so that the condensing surface is kept relatively free of liquid at any attitude. The heat pipe may be incorporated in an air conditioning apparatus so that it projects through a small wall opening. In the preferred air conditioning apparatus, a hollow hermetic air impeller is provided which contains a liquefied gaseous refrigerant, such as freon, and means are provided for compressing the refrigerant in the evaporator region of the heat pipe.

Gray, V.H.

1976-12-28T23:59:59.000Z

290

Glass heat pipe evacuated tube solar collector  

DOE Patents (OSTI)

A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.

McConnell, Robert D. (Lakewood, CO); Vansant, James H. (Tracy, CA)

1984-01-01T23:59:59.000Z

291

Solar Heat-Pipe Receiver Wick Modeling  

DOE Green Energy (OSTI)

Stirling-cycle engines have been identified as a promising technology for the conversion of concentrated solar energy into usable electrical power. In previous experimented work, we have demonstrated that a heat pipe receiver can significantly improve system performance-over a directly-illuminated heater head. The design and operating conditions of a heat pipe receiver differ significantly from typical laboratory heat pipes. New wick structures have been developed to exploit the characteristics of the solar generation system. Typically, these wick structures allow vapor generation within the wick. Conventional heat pipe models do not handle this enhancement yet it can more than double the performance of the wick. In this study, I develop a steady-state model of a boiling-enhanced wick for a solar heat pipe receiver. The model is used for design-point calculations and is written in FORTRAN90. Some limited comparisons have been made with actual test data.

Andraka, C.E.

1998-12-21T23:59:59.000Z

292

Valve for gas centrifuges  

DOE Patents (OSTI)

The invention is pneumatically operated valve assembly for simulatenously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two on the lines so closed. The value assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.

Hahs, C.A.; Rurbage, C.H.

1982-03-17T23:59:59.000Z

293

Four-port gas separation membrane module assembly  

DOE Patents (OSTI)

A gas-separation membrane assembly, and a gas-separation process using the assembly. The assembly incorporates multiple gas-separation membranes in an array within a single vessel or housing, and is equipped with two permeate ports, enabling permeate gas to be withdrawn from both ends of the membrane module permeate pipes.

Wynn, Nicholas P. (Redwood City, CA); Fulton, Donald A. (Fairfield, CA); Lokhandwala, Kaaeid A. (Fremont, CA); Kaschemekat, Jurgen (Campbell, CA)

2010-07-20T23:59:59.000Z

294

Heat pipe reactors for space power applications  

SciTech Connect

A family of heat pipe reactors design concepts has been developed to provide heat to a variety of electrical conversion systems. Three power plants are described that span the power range 1-500 kW(e) and operate in the temperature range 1200 to 1700/sup 0/K. The reactors are fast, compact, heat-pipe cooled, high-temperature nuclear reactors fueled with fully enriched refractory fuels, UC-ZrC or UO/sub 2/. Each fuel element is cooled by an axially located molybdenum heat pipe containing either sodium or lithium vapor.

Koenig, D.R.; Ranken, W.A.; Salmi, E.W.

1977-01-01T23:59:59.000Z

295

Heat pipe testing program test plan  

SciTech Connect

A test plan is given which describes the tests to be conducted on several typical solar receiver heat pipes. The hardware to be used, test fixtures and rationale of the test program are discussed. The program objective is to perform life testing under simulated receiver conditions, and to conduct performance tests with selected heat pipes to further map their performance, particularly with regard to their transient behavior. Performance requirements are defined. Test fixtures designed for the program are described in detail, and their capabilities for simulating the receiver conditions and their limitations are discussed. The heat pipe design is given. (LEW)

Bienert, W.B.

1980-03-14T23:59:59.000Z

296

Natural gas imports and exports. Second quarter report 1995  

SciTech Connect

This quarter`s feature report focuses on natural gas exports to Mexico. OFP invites ideas from the public on future topics dealing with North American natural gas import/export trade. Such suggestions should be left on OFP`s electronic bulletin board. Natural Gas exports to Mexico continued to grow and reached an historic high for the month of June (7.8 Bcf). Two new long-term contracts were activated; Pennsylvania Gas & Water Company began importing 14.7 MMcf per day from TransCanada PipeLines Ltd., and Renaissance Energy (U.S.) Inc. began importing 2.8 MMcf per day from Renaissance Energy Ltd. for resale to Delmarva Power & Light Company. Algerian LNG imports remained stagnant with only one tanker being imported by Pan National Gas Sales, Inc. (Pan National). During the first six months of 1995, data indicates gas imports increased by about 10 percent over the 1994 level (1,418 vs. 1,285 Bcf), with Canadian imports increasing by 14 percent and Algerian imports decreasing by 81 percent. During the same time period, exports increased by 18 percent (83 vs. 70.1 Bcf).

NONE

1995-12-31T23:59:59.000Z

297

New and Underutilized Technology: Wrap Around Heat Pipes  

Energy.gov (U.S. Department of Energy (DOE))

The following information outlines key deployment considerations for wrap around heat pipes within the Federal sector.

298

Dry Pipe Sprinkler Piping Replacement Project (4588), 4/30/2012  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pipe System Sprinkler Piping Replacement Projects (4588) Pipe System Sprinkler Piping Replacement Projects (4588) Program or Field Office: Y-12 Site Office Location(s) (City/County/State): Oak Ridge, Anderson County, Tennessee Proposed Action Description: Submit by E-mail The proposed action is to replace sections of dry pipe system sprinkler piping which include heads, hangers, fittings, and valves. Categorical Exclusion(s) Applied: 81.3- Routine maintenance For the complete DOE National Environmental Policy Act regulations regarding categorical exclusions, including the full text of each categorical exclusion, see Subpart D of I 0 CFR Part I 021. Regulatory Requirements in 10 CFR 1021.410(b): (See full text in regulation) [{Jrhe proposal fits within a class of actions that is listed in Appendix A orB to 10 CFR Part 1021, Subpart D.

299

Corrosion of Buried Steel Pipes Used With Transmission Pipe-Type Cable Systems  

Science Conference Proceedings (OSTI)

Although pipe-type underground transmission cables were designed with a life expectancy of 40 years, many of these cables have reached this threshold and are still performing satisfactorily. The buried steel pipes that surround the cables are protected by coatings and cathodic-protection systems. These protective systems need to be routinely inspected and maintained in order to extend their own life expectancy and thereby protect the cables within the steel pipes. This report provides research results an...

2010-12-23T23:59:59.000Z

300

Analytical and experimental studies of heat pipe radiation cooling of hypersonic propulsion systems  

SciTech Connect

Preliminary, research-oriented, analytical and experimental studies were completed to assess the feasibility of using high-temperature heat pipes to cool hypersonic engine components. This new approach involves using heat pipes to transport heat away from the combustor, nozzle, or inlet regions, and to reject it to the environment by thermal radiation from an external heat pipe nacelle. For propulsion systems using heat pipe radiation cooling (HPRC), it is possible to continue to use hydrocarbon fuels into the Mach 4 to Mach 6 speed range, thereby enhancing the economic attractiveness of commercial or military hypersonic flight. In the second-phase feasibility program recently completed, we found that heat loads produced by considering both convection and radiation heat transfer from the combustion gas can be handled with HPRC design modifications. The application of thermal insulation to ramburner and nozzle walls was also found to reduce the heat load by about one-half and to reduce peak HPRC system temperatures to below 2700{degrees}F. In addition, the operation of HPRC at cruise conditions of around Mach 4.5 and at an altitude of 90, 000 ft lowers peak hot section temperatures to around 2800{degrees}F. An HPRC heat pipe was successfully fabricated and tested at Mach 5 conditions of heat flux, heat load, and temperature. 24 refs.

Martin, R.A.; Merrigan, M.A.; Elder, M.G.; Sena, J.T.; Keddy, E.S. (Los Alamos National Lab., NM (United States)); Silverstein, C.C. (CCS Associates, Bethel Park, PA (United States))

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Analytical and experimental studies of heat pipe radiation cooling of hypersonic propulsion systems  

SciTech Connect

Preliminary, research-oriented, analytical and experimental studies were completed to assess the feasibility of using high-temperature heat pipes to cool hypersonic engine components. This new approach involves using heat pipes to transport heat away from the combustor, nozzle, or inlet regions, and to reject it to the environment by thermal radiation from an external heat pipe nacelle. For propulsion systems using heat pipe radiation cooling (HPRC), it is possible to continue to use hydrocarbon fuels into the Mach 4 to Mach 6 speed range, thereby enhancing the economic attractiveness of commercial or military hypersonic flight. In the second-phase feasibility program recently completed, we found that heat loads produced by considering both convection and radiation heat transfer from the combustion gas can be handled with HPRC design modifications. The application of thermal insulation to ramburner and nozzle walls was also found to reduce the heat load by about one-half and to reduce peak HPRC system temperatures to below 2700{degrees}F. In addition, the operation of HPRC at cruise conditions of around Mach 4.5 and at an altitude of 90, 000 ft lowers peak hot section temperatures to around 2800{degrees}F. An HPRC heat pipe was successfully fabricated and tested at Mach 5 conditions of heat flux, heat load, and temperature. 24 refs.

Martin, R.A.; Merrigan, M.A.; Elder, M.G.; Sena, J.T.; Keddy, E.S. [Los Alamos National Lab., NM (United States); Silverstein, C.C. [CCS Associates, Bethel Park, PA (United States)

1992-06-01T23:59:59.000Z

302

Fossil Plant High Energy Piping Damage: Theory and Practice  

Science Conference Proceedings (OSTI)

Condition assessment programs for high-energy piping systems are often a major aspect of a fossil utility's inspection and maintenance program. In the past 30 years, a number of major failures of fossil high-energy piping have been associated with flow-accelerated corrosion of feedwater piping, creep failures of longitudinal seam-welded hot reheat and main steam piping, and corrosion fatigue failures of cold reheat steam piping. In addition to these well-documented failures, most utilities experience fai...

2007-11-29T23:59:59.000Z

303

Fossil Plant High-Energy Piping Damage: Theory and Practice  

Science Conference Proceedings (OSTI)

Condition assessment programs for high-energy piping systems are often a major aspect of a fossil utility's inspection and maintenance program. In the past 30 years, a number of major failures of fossil high-energy piping have been associated with flow-accelerated corrosion of feedwater piping, creep failures of longitudinal seam-welded hot reheat and main steam piping, and corrosion fatigue failures of cold reheat steam piping. In addition to these well-documented failures, most utilities experience fai...

2007-06-26T23:59:59.000Z

304

Dehumidifying Heat Pipes | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Dehumidifying Heat Pipes Dehumidifying Heat Pipes Dehumidifying Heat Pipes June 24, 2012 - 4:32pm Addthis In order to make a room comfortable in hot, humid climates, an air conditioner must lower the indoor humidity level as well as the air temperature. If an air conditioner fails to lower the humidity adequately, the air will be cool, but will feel uncomfortably damp. Inappropriately sized air conditioners are prone to this problem; large units quickly cool the air, but cycle off before they can properly dehumidify it. In extremely humid climates, even correctly sized air conditioning equipment could fail to maintain a home at a comfortable humidity level. One technology that addresses this problem is the dehumidifying heat pipe, a device that enables an air conditioner to dehumidify better and still

305

Heat pipe effect in porous medium  

SciTech Connect

In this thesis a parametric study of the thermal and hydrologic characteristics of the fractured porous tuffs at Yucca Mountain, Nevada was conducted. The effects of different fracture and matrix properties including permeability, thermal conductivity, specific heat, porosity, and tortuosity on heat pipe performance in the vicinity of the waste package were observed. Computer simulations were carried out using TOUGH code on a Cray YMP-2 supercomputer. None of the fracture parameters affected the heat pipe performance except the mobility of the liquid in the fracture. Matrix permeability and thermal conductivity were found to have significant effect on the heat pipe performance. The effect of mass injection was studied for liquid water and air injected at the fracture boundary. A high rate of mass injection was required to produce any effect on the heat pipe. The fracture-matrix equilibrium is influenced by the matrix permeability and the matrix thermal conductivity.

Joseph, M.

1992-12-01T23:59:59.000Z

306

Heat pipe dehumidification for supermarket energy savings  

E-Print Network (OSTI)

This thesis examines the possibility of using a heat pipe installed in the air conditioning unit of a supermarket to increase the level of dehumidification of the inside air. This dehumidification is expected to reduce the ...

Oliver, Eric M. (Eric Michael)

1994-01-01T23:59:59.000Z

307

Aerogel Impregnated Polyurethane Piping and Duct Insulation  

NLE Websites -- All DOE Office Websites (Extended Search)

Aerogel Impregnated Polyurethane Piping and Duct Insulation David M. Hess InnoSense LLC david.hess@innosense.us, 310-530-2011 April 4, 2013 2 | Building Technologies Office...

308

The Use of Weld Overlays to Extend the Life of Seam Welded High Energy Piping in Fossil Power Plants: Common PQR and Thinner Piping Evaluation  

Science Conference Proceedings (OSTI)

Replacement of longitudinally welded reheat and main steam lines is very expensive and can result in extended outages. Inspection and re-inspection of such systems every few years is also expensive and time consuming. An alternative to continued inspection or system replacement is weld overlay. Weld overlay of longitudinal seamed clamshell elbows was investigated in "The Use of Weld Overlays to Extend the Useful Life of Seam Welded High Energy Piping in Fossil Power Plants" (EPRI Report No. 1001270, Febr...

2002-02-28T23:59:59.000Z

309

Aerogel Impregnated Polyurethane Piping and Duct Insulation  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Aerogel Impregnated Polyurethane Aerogel Impregnated Polyurethane Piping and Duct Insulation David M. Hess InnoSense LLC david.hess@innosense.us, 310-530-2011 April 4, 2013 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: Develop an efficient insulation system that will adhere to housing duct work and pipe structures while conforming to complex geometries. New insulations must increase the R-value of existing materials and be easy to apply or retrofit to existing structures.

310

Dynamic simulation recalls condensate piping event  

Science Conference Proceedings (OSTI)

This article describes how experience gained from simulating and reconstructing a condensate piping event will be used by Consolidated Edison to analyze control system problems. A cooperative effort by Con Edison and the Chemical Engineering Department at Polytechnic University used modular modeling system to investigate the probable cause of a Con Edison condensate piping event. Con Edison commissioned the work to serve as a case study for the more general problem of control systems analysis using dynamic simulation and MMS.

Farrell, R.J.; Reneberg, K.O. (Polytechnic Univ., Brooklyn, NY (United States)); Moy, H.C. (Consolidated Edison Co., New York, NY (United States))

1994-05-01T23:59:59.000Z

311

Seismic analysis of piping with nonlinear supports  

Science Conference Proceedings (OSTI)

The modeling and results of nonlinear time-history seismic analyses for three sizes of pipelines restrained by mechanical snubbes are presented. Numerous parametric analyses were conducted to obtain sensitivity information which identifies relative importance of the model and analysis ingredients. Special considerations for modeling the pipe clamps and the mechanical snubbers based on experimental characterization data are discussed. Comparisions are also given of seismic responses, loads and pipe stresses predicted by standard response spectra methods and the nonlinear time-history methods.

Barta, D.A.; Huang, S.N.; Severud, L.K.

1980-01-01T23:59:59.000Z

312

DEVELOPMENT OF TECHNOLOGY TO REMOTELY NAVIGATE VERTICAL PIPE ARRAYS  

Science Conference Proceedings (OSTI)

Situations exist around the Savannah River Site (SRS) and the Department of Energy (DOE) complex where it is advantageous to remotely navigate vertical pipe arrays. Specific examples are waste tanks in the SRS Tank Farms, which contain horizontal cooling coils at the tank bottom, vertical cooling coils throughout and a limited number of access points or ''risers''. These factors limit accessibility to many parts of these tanks by conventional means. Pipe Traveler technology has been developed to address these issues. The Pipe Traveler addresses these issues by using the vertical cooling coils as its medium of travel. The unit operates by grabbing a pipe using dual grippers located on either side of the equipment. Once securely attached to the pipe a drive wheel is extended to come in contact with the pipe. Rotation of the drive wheel causes the unit to rotate around the pipe. This action is continued until the second set of grippers is aligned with the next pipe. Extension pistons are actuated to extend the second set of grippers in contact with a second pipe. The second set of grippers is then actuated to grasp the pipe. The first set of grippers releases the original pipe and the process is repeated until the unit reaches its desired location. Once at the tool deployment location the desired tool may be used. The current design has proven the concept of pipe-to-pipe navigation. Testing of the Pipe Traveler has proven its ability to transfer itself from one pipe to another.

Krementz, D.; Immel, D.; Vrettos, N.; Nance, T.; Marzolf, A.

2011-07-01T23:59:59.000Z

313

Conceptual design of a heat pipe radiator  

SciTech Connect

A conceptual design of a waste heat radiator has been developed for a thermoelectric space nuclear power system. The basic shape of the heat pipe radiator was a frustum of a right circular cone. The design included stringer heat pipes to carry reject heat from the thermoelectric modules to the radiator skin that was composed of small-diameter, thin-walled cross heat pipes. The stringer heat pipes were armored to resist puncture by a meteoroid. The cross heat pipes were designed to provide the necessary unpunctured radiating area at the mission end with a minimum initial system mass. Several design cases were developed in which the individual stringer survival probabilities were varied and the radiator system mass was calculated. Results are presented for system mass as a function of individual stringer survival probability for six candidate container materials, three candidate heat pipe fluids, two radiator operating temperatures, two meteoroid shield types, and two radiating surface cases. Results are also presented for radiator reject heat as a function of system mass, area, and length for three system sizes.

Bennett, G.A.

1977-09-01T23:59:59.000Z

314

Primary Piping Static Test Design Request  

SciTech Connect

It is requested that a design be initiated for the primary piping static test. This test is necessary to provide information as to the reliability of the pipe subjected to reactor operating conditions. The test conditions are as follows: temperature - 2000 F (isothermal), pressure effective - 42 psi, and test time - 10,000 hours. It will be necessary to test two sizes of pipe as shown on the preliminary piping layout (2.250-inch O.D. x .095-inch wall and 3 1/2 SCH. 10 pipe). The test specimens shall be jacketed in an inconel containment vessel. The test rig should be similar to the design of the 4-inch pressure vessels (T-1030244). In addition an outer containment vessel constructed of stainless steel must be provided around the clam shell heaters and the inconel containment vessel. This is to provide an inert atmosphere for the inconel vessel. Provisions should be made in the design for a 1/4-inch clad thermocouple. It is planned to use the pipe test as a vehicle for studying experimental Tc's (Cb-Mo and W-W.26% Re).

O' Brien, R.W.

1961-11-30T23:59:59.000Z

315

Natural Gas Weekly Update  

Annual Energy Outlook 2012 (EIA)

damage was not immediately clear, and the pipeline did not indicate how long the three lines will be out of service. Texas Gas Transmission Company has begun unscheduled...

316

Regulations for Electric Transmission and Fuel Gas Transmission...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electric Transmission and Fuel Gas Transmission Lines Ten or More Miles Long (New York) Regulations for Electric Transmission and Fuel Gas Transmission Lines Ten or More Miles Long...

317

A Temperature-Profile Method for Estimating Flow Processes in Geologic Heat Pipes  

E-Print Network (OSTI)

change and capillarity—the heat pipe effect, Int. J. Heatgeothermal reservoirs as heat pipes in fractured porousProcesses in Geologic Heat Pipes Jens T. Birkholzer Ernest

Birkholzer, Jens T.

2004-01-01T23:59:59.000Z

318

Building Energy Software Tools Directory: Pipe-Flo  

NLE Websites -- All DOE Office Websites (Extended Search)

Pipe-Flo Pipe-Flo Pipe-flo logo Flow analysis software used to design, optimize, troubleshoot and simulate the operation of piping systems of any size or configuration. PIPE-FLO provides a total picture of the piping system including the flow and pressures in pipelines, along with the interaction of pumps, control valves, and flow meters. PIPE-FLO products are used worldwide in a variety of applications throughout many industries including HVAC, fire sprinkler, wastewater collection and treatment, mining, ultra-pure water, chemical processing, power generation, pulp & paper and general industrial. Screen Shots Keywords piping analysis, pump selection, piping design, hydraulic analysis, pump sizing, pressure drop calculator, hydraulic modeling, steam distribution,

319

Apparatus and method for detecting leaks in piping  

DOE Patents (OSTI)

A method and device are disclosed for detecting the location of leaks along a wall or piping system, preferably in double-walled piping. The apparatus comprises a sniffer probe, a rigid cord such as a length of tube attached to the probe on one end and extending out of the piping with the other end, a source of pressurized air and a source of helium. The method comprises guiding the sniffer probe into the inner pipe to its distal end, purging the inner pipe with pressurized air, filling the annulus defined between the inner and outer pipe with helium, and then detecting the presence of helium within the inner pipe with the probe as is pulled back through the inner pipe. The length of the tube at the point where a leak is detected determines the location of the leak in the pipe. 2 figures.

Trapp, D.J.

1994-12-27T23:59:59.000Z

320

Mutual Design Considerations for Overhead AC Transmission Lines and Gas Transmission Pipelines: Volume 1: Engineering Analysis; Volu me 2: Prediction and Mitigation Procedures  

Science Conference Proceedings (OSTI)

This joint-effort project between Pipeline Research Committee of the A.G.A. and EPRI was initiated to develop analytical techniques for determining the induced potential on pipelines that parallel electric transmission lines. Its purpose was to develop analytical methods for prediction and mitigation of voltages induced on pipelines by nearby ac transmission lines. Required analytical techniques were developed and supported by field test results. New mitigation methods were developed and old ones evaluat...

1978-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Natural gas pipeline capacity additions in 2011 - Today in ...  

U.S. Energy Information Administration (EIA)

The U.S. Energy Information Administration estimates that U.S. natural gas pipeline companies added about 2,400 miles of new pipe to the grid as part ...

322

Model relaxations for the fuel cost minimization of steady-state gas pipeline networks  

Science Conference Proceedings (OSTI)

Natural gas, driven by pressure, is transported through pipeline network systems. As the gas flows through the network, energy and pressure are lost due to both friction between the gas and the pipes' inner wall, and heat transfer between the gas and ... Keywords: Compressor stations, Lower bounds, Natural gas, Nonconvex objective, Pipelines, Steady state, Transmission networks

Suming Wu; R. Z. Ríos-Mercado; E. A. Boyd; L. R. Scott

2000-01-01T23:59:59.000Z

323

Modeling of pulsating heat pipes.  

SciTech Connect

This report summarizes the results of a computer model that describes the behavior of pulsating heat pipes (PHP). The purpose of the project was to develop a highly efficient (as compared to the heat transfer capability of solid copper) thermal groundplane (TGP) using silicon carbide (SiC) as the substrate material and water as the working fluid. The objective of this project is to develop a multi-physics model for this complex phenomenon to assist with an understanding of how PHPs operate and to be able to understand how various parameters (geometry, fill ratio, materials, working fluid, etc.) affect its performance. The physical processes describing a PHP are highly coupled. Understanding its operation is further complicated by the non-equilibrium nature of the interplay between evaporation/condensation, bubble growth and collapse or coalescence, and the coupled response of the multiphase fluid dynamics among the different channels. A comprehensive theory of operation and design tools for PHPs is still an unrealized task. In the following we first analyze, in some detail, a simple model that has been proposed to describe PHP behavior. Although it includes fundamental features of a PHP, it also makes some assumptions to keep the model tractable. In an effort to improve on current modeling practice, we constructed a model for a PHP using some unique features available in FLOW-3D, version 9.2-3 (Flow Science, 2007). We believe that this flow modeling software retains more of the salient features of a PHP and thus, provides a closer representation of its behavior.

Givler, Richard C.; Martinez, Mario J.

2009-08-01T23:59:59.000Z

324

State-of-the-art report on piping fracture mechanics  

Science Conference Proceedings (OSTI)

This report is an in-depth summary of the state-of-the-art in nuclear piping fracture mechanics. It represents the culmination of 20 years of work done primarily in the US, but also attempts to include important aspects from other international efforts. Although the focus of this work was for the nuclear industry, the technology is also applicable in many cases to fossil plants, petrochemical/refinery plants, and the oil and gas industry. In compiling this detailed summary report, all of the equations and details of the analysis procedure or experimental results are not necessarily included. Rather, the report describes the important aspects and limitations, tells the reader where he can go for further information, and more importantly, describes the accuracy of the models. Nevertheless, the report still contains over 150 equations and over 400 references. The main sections of this report describe: (1) the evolution of piping fracture mechanics history relative to the developments of the nuclear industry, (2) technical developments in stress analyses, material property aspects, and fracture mechanics analyses, (3) unresolved issues and technically evolving areas, and (4) a summary of conclusions of major developments to date.

Wilkowski, G.M.; Olson, R.J.; Scott, P.M. [Battelle, Columbus, OH (United States)

1998-01-01T23:59:59.000Z

325

Heat pipes for use in a magnetic field  

DOE Patents (OSTI)

A heat pipe configuration is described for use in a magnetic field environment of a fusion reactor. Heat pipes for operation in a magnetic field when liquid metal working fluids are used are optimized by flattening of the heat pipes having an unobstructed annulus which significantly reduces the adverse side region effect of the prior known cylindrically configured heat pipes. The flattened heat pipes operating in a magnetic field can remove 2 to 3 times the heat as a cylindrical heat pipe of the same cross sectional area.

Werner, R.W.; Hoffman, M.A.

1981-04-29T23:59:59.000Z

326

Heat pipes for use in a magnetic field  

DOE Patents (OSTI)

A heat pipe configuration for use in a magnetic field environment of a fusion reactor is disclosed. Heat pipes for operation in a magnetic field when liquid metal working fluids are used are optimized by flattening of the heat pipes having an unobstructed annulus which significantly reduces the adverse side region effect of the prior known cylindrically configured heat pipes. The flattened heat pipes operating in a magnetic field can remove 2--3 times the heat as a cylindrical heat pipe of the same cross sectional area. 4 figs.

Werner, R.W.; Hoffman, M.A.

1983-07-19T23:59:59.000Z

327

Heat pipes for use in a magnetic field  

DOE Patents (OSTI)

A heat pipe configuration for use in a magnetic field environment of a fusion reactor. Heat pipes for operation in a magnetic field when liquid metal working fluids are used are optimized by flattening of the heat pipes having an unobstructed annulus which significantly reduces the adverse side region effect of the prior known cylindrically configured heat pipes. The flattened heat pipes operating in a magnetic field can remove 2--3 times the heat as a cylindrical heat pipe of the same cross sectional area.

Werner, Richard W. (San Ramon, CA); Hoffman, Myron A. (Davis, CA)

1983-01-01T23:59:59.000Z

328

Automated on-line determination of PPB levels of sodium and potassium in low-Btu coal gas and fluidized bed combustor exhaust by atomic emission spectrometry  

SciTech Connect

The Morgantown Energy Technology Center (METC), US Department of Energy, is involved in the development of processes and equipment for production of low-Btu gas from coal and for fluidized bed combustion of coal. The ultimate objective is large scale production of electricity using high temperature gas turbines. Such turbines, however, are susceptible to accelerated corrosion and self-destruction when relatively low concentrations of sodium and potassium are present in the driving gas streams. Knowledge and control of the concentrations of those elements, at part per billion levels, are critical to the success of both the gas cleanup procedures that are being investigated and the overall energy conversion processes. This presentation describes instrumentation and procedures developed at the Ames Laboratory for application to the problems outlined above and results that have been obtained so far at METC. The first Ames instruments, which feature an automated, dual channel flame atomic emission spectrometer, perform the sodium and potassium determinations simultaneously, repetitively, and automatically every two to three minutes by atomizing and exciting a fraction of the subject gas sample stream in either an oxyhydrogen flame or a nitrous oxide-acetylene flame. The analytical results are printed and can be transmitted simultaneously to a process control center.

Haas, W.J. Jr.; Eckels, D.E.; Kniseley, R.N.; Fassel, V.A.

1981-01-01T23:59:59.000Z

329

EIA - Natural Gas Pipeline Network - Natural Gas Pipeline Development &  

U.S. Energy Information Administration (EIA) Indexed Site

Pipelinesk > Development & Expansion Pipelinesk > Development & Expansion About U.S. Natural Gas Pipelines - Transporting Natural Gas based on data through 2007/2008 with selected updates Natural Gas Pipeline Development and Expansion Timing | Determining Market Interest | Expansion Options | Obtaining Approval | Prefiling Process | Approval | Construction | Commissioning Timing and Steps for a New Project An interstate natural gas pipeline construction or expansion project takes an average of about three years from the time it is first announced until the new pipe is placed in service. The project can take longer if it encounters major environmental obstacles or public opposition. A pipeline development or expansion project involves several steps: Determining demand/market interest

330

Design and demonstration of heat pipe cooling for NASP and evaluation of heating methods at high heating rates  

SciTech Connect

An evaluation of two heating methods for demonstration of NASP leading edge heat pipe technology was conducted. The heating methods were and rf induction heated plasma jet and direct rf induction. Tests were conducted to determine coupling from the argon plasma jet on a surface physically similar to a heat pipe. A molybdenum tipped calorimeter was fabricated and installed in an rf induction heated plasma jet for the test. The calorimetric measurements indicated a maximum power coupling of approximately 500 W/cm{sup 2} with the rf plasma jet. The effect of change in gas composition on the heating rate was investigated using helium. An alternative to the plasma heating of a heat pipe tip, an rf concentrator was evaluated for coupling to the hemispherical tip of a heat pipe. A refractory metal heat pipe was designed, fabricated, and tested for the evaluation. The heat pipe was designed for operation at 1400 to 1900 K with power input to 1000 W/cm{sup 2} over a hemispherical nose tip. Power input of 800 W/cm{sup 2} was demonstrated using the rf concentrator. 2 refs., 13 figs.

Merrigan, M.A.; Sena, J.T.

1989-01-01T23:59:59.000Z

331

The IRAM-30m line survey of the Horsehead PDR: III. High abundance of complex (iso-)nitrile molecules in UV-illuminated gas  

E-Print Network (OSTI)

Complex (iso-)nitrile molecules, such as CH3CN and HC3N, are relatively easily detected in our Galaxy and in other galaxies. We constrain their chemistry through observations of two positions in the Horsehead edge: the photo-dissociation region (PDR) and the dense, cold, and UV-shielded core just behind it. We systematically searched for lines of CH3CN, HC3N, C3N, and some of their isomers in our sensitive unbiased line survey at 3, 2, and 1mm. We derived column densities and abundances through Bayesian analysis using a large velocity gradient radiative transfer model. We report the first clear detection of CH3NC at millimeter wavelength. We detected 17 lines of CH3CN at the PDR and 6 at the dense core position, and we resolved its hyperfine structure for 3 lines. We detected 4 lines of HC3N, and C3N is clearly detected at the PDR position. We computed new electron collisional rate coefficients for CH3CN, and we found that including electron excitation reduces the derived column density by 40% at the PDR posi...

Gratier, P; Guzmán, V; Gerin, M; Goicoechea, J R; Roueff, E; Faure, A

2013-01-01T23:59:59.000Z

332

Help Line  

NLE Websites -- All DOE Office Websites (Extended Search)

Help Line Help Line Ombuds Help Line Committed to the fair and equitable treatment of all employees, contractors, and persons doing business with the Laboratory. Contact Ombuds Office (505)665-2837 Email Help Line (505) 667-9370 Fax (505) 667-3119 Map & Hours Help Line: (505) 667-9370 As an option to visiting the Ombuds office, we provide service through a telephone Help Line and email. The telephone Help Line is useful for individuals who have concerns and want advice or referral while preserving confidentiality and anonymity. Callers may remain anonymous and the Help Line does not have caller ID or other methods of identifying callers. The Help Line maintains the same level of confidentiality and neutrality as the other Ombuds services. The Ombuds Help Line is not for reporting emergencies or officially

333

Deep water pipe, pump, and mooring study: Ocean Thermal Energy Conversion program. Final report  

DOE Green Energy (OSTI)

The ocean engineering issues affecting the design, construction, deployment, and operation of Ocean Thermal Energy Conversion (OTEC) power plants are of key importance. This study addressed the problems associated with the conceptual design of the deep-water pipe, cold-water-pumping, and platform mooring arrangements. These subsystems fall into a natural grouping since the parameters affecting their design are closely related to each other and to the ocean environment. Analysis and evaluations are provided with a view toward judging the impact of the various subsystems on the overall plant concept and to provide an estimate of material and construction cost. Parametric data is provided that describes mooring line configurations, mooring line loads, cold water pipe configurations, and cold water pumping schemes. Selected parameters, issues, and evaluation criteria are used to judge the merits of candidate concepts over a range of OTEC plant size from 100 MWe to 1000 MWe net output power.

Little, T.E.; Marks, J.D.; Wellman, K.H.

1976-06-01T23:59:59.000Z

334

Corrugated Pipe as a Beam Dechirper  

SciTech Connect

We have studied the use of a metallic pipe with small corrugations for the purpose of passively dechirping, through its wakefield, a short, intense electron bunch. The corrugated pipe is attractive for this purpose because its wake: (i) has near maximal possible amplitude for a given aperture and (ii) has a relatively large oscillation wave length, even when the aperture is small. We showed how the corrugated structure can satisfy dechirping requirements encountered in the NGLS project at LBNL. We found that a linear chirp of -40 MeV/mm can be induced by an NGLS-like beam, by having it pass through a corrugated, metallic pipe of radius 3 mm, length 8.2 m, and corrugation parameters full depth 450 {mu}m and period 1000 {mu}m. This structure is about 15 times as effective in the role of dechirper as an S-band accelerator structure used passively.

Bane, K.L.F.; Stupakov, G.; /SLAC

2012-04-20T23:59:59.000Z

335

Industrial Waste Heat Recovery Using Heat Pipes  

E-Print Network (OSTI)

For almost a decade now, heat pipes with secondary finned surfaces have been utilized in counter flow heat exchangers to recover sensible energy from industrial exhaust gases. Over 3,000 such heat exchangers are now in service, recovering an estimated energy equivalent of nearly 1.1 million barrels of oil annually. Energy recovered by these units has been used to either preheat process supply air or to heat plant comfort make-up air. Heat pipe heat exchangers have been applied to an ever-expanding variety of industrial processes. One notable application in recent years has been for combustion airs preheat of fired heaters in petroleum refineries and petrochemical plants. Another recent development has been a waste heat recovery boiler using heat pipes. This device has a number of advantageous features. Field operational experience of several units in service has been excellent.

Ruch, M. A.

1981-01-01T23:59:59.000Z

336

New advances in mitigating environmental impact of pipe-type cables  

Science Conference Proceedings (OSTI)

Through a comprehensive and aggressive research program Consolidated Edison Company of New York, Inc. (Con Edison) has designed, developed, and installed several new products to address the environmental impact of dielectric fluid from pipe-type cable systems. These include: On Line Leak Detection, Leak Location, Retractable Flow Direction Indicator, Full Stop Joints, and Transition Joints. This paper describes the application of the aforementioned products on the Con Edison underground transmission system.

Ghafurian, R.; Dominguez, J.; Santini, A.; Sobel, C. [Consolidated Edison Co. of New York, Inc., New York, NY (United States)] [Consolidated Edison Co. of New York, Inc., New York, NY (United States)

1999-04-01T23:59:59.000Z

337

Savings Project: Insulate Hot Water Pipes for Energy Savings...  

NLE Websites -- All DOE Office Websites (Extended Search)

the insulation done during new construction of a home, during other work on your water heater or pipes, or insulating the pipes yourself, is well worth the effort. In special...

338

Savings Project: Insulate Hot Water Pipes for Energy Savings | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Insulate Hot Water Pipes for Energy Savings Insulate Hot Water Pipes for Energy Savings Savings Project: Insulate Hot Water Pipes for Energy Savings Addthis Project Level Medium Energy Savings $8-$12 annually Time to Complete 3 hours for a small house Overall Cost $10-$15 Insulating water pipes can save you water, energy, and money. | Photo courtesy of iStockphoto.com/nsj-images Insulating water pipes can save you water, energy, and money. | Photo courtesy of iStockphoto.com/nsj-images Insulating your hot water pipes reduces heat loss and can raise water temperature 2°F-4°F hotter than uninsulated pipes can deliver, allowing for a lower water temperature setting. You also won't have to wait as long for hot water when you turn on a faucet or showerhead, which helps conserve water. Paying for someone to insulate your pipes-as a project on its own-may

339

Smoothing of pipe system completion processes in a shipyard environment/  

E-Print Network (OSTI)

Due to a number of different production issues, the manufacture of template pipes is often delayed. These delays hold up pipe system completion on board the ships in production and can delay payments from the Ministry of ...

Zojwalla, Shaheen J. (Shaheen Joyab), 1977-

2004-01-01T23:59:59.000Z

340

Development and Testing of Insulated Drill Pipe  

DOE Green Energy (OSTI)

This project has comprised design, analysis, laboratory testing, and field testing of insulated drill pipe (IDP). This paper will briefly describe the earlier work, but will focus on results from the recently-completed field test in a geothermal well. Field test results are consistent with earlier analyses and laboratory tests, all of which support the conclusion that insulated drill pipe can have a very significant effect on circulating fluid temperatures. This will enable the use of downhole motors and steering tools in hot wells, and will reduce corrosion, deterioration of drilling fluids, and heat-induced failures in other downhole components.

Champness, T.; Finger, J.; Jacobson, R.

1999-07-07T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Heat pipe technology. Quarterly update, March 31, 1976  

SciTech Connect

Heat Pipe Technology is a continuing bibliographic summary of research on heat pipes. The first volume was published in the spring of 1971 and is cumulative through March of that year. The 1971, 1972, 1973 and 1974 Annual Supplements have been published and distributed. This update to Heat Pipe Technology cites the additional references identified during January, February and March of 1976. It is intended to provide ''current awareness'' to heat pipe researchers.

1976-01-01T23:59:59.000Z

342

Fire Testing of High-Density Polyethylene Pipe  

Science Conference Proceedings (OSTI)

The results in this report are intended to demonstrate a method that can be used to protect high-density polyethylene (HDPE) piping located aboveground from postulated fire events. This includes protecting both pipe and pipe fittings (for example, elbows, tees, and valves) from the fire environmentincluding the heat transmitted from pipe supportsand preventing the fire environment from passing through building wall or floor penetrations. The report is intended to be complementary to other ongoing Electr...

2011-08-23T23:59:59.000Z

343

Molecular Gas in Early-type Galaxies  

E-Print Network (OSTI)

toward the center (first seen in the molecular gas in A+The EVLA . . . . . . . . . . . . . . . . 3.3 Molecular LineProfile . . . . . . . . . . . . . . 3.4 Molecular Gas

Alatalo, Katherine Anne

2012-01-01T23:59:59.000Z

344

Impacts of Soil and Pipe Thermal Conductivity on Performance of Horizontal Pipe in a Ground-source Heat Pump  

E-Print Network (OSTI)

In this paper the composition and thermal property of soil are discussed. The main factors that impact the soil thermal conductivity and several commonly-used pipe materials are studied. A model of heat exchanger with horizontal pipes of ground-source heat pump is developed. The impact of soil thermal conductivity and pipe thermal conductivity on the soil temperature field around the buried pipe, and the thermal performance of the heat exchanger are simulated. The simulation results show that with the increase of soil thermal conductivity, heat transfer quantity obviously increases, and the temperature of soil around pipe decrease under winter conditions. The temperature field varies relatively faster with thermal conductivity in the site nearer to the buried pipe. With the increase of pipe thermal conductivity, heat transfer quantity and the mean temperature of the buried pipe's outside surface all increase.

Song, Y.; Yao, Y.; Na, W.

2006-01-01T23:59:59.000Z

345

Gary Phetteplace August 1995 Optimal Design of Piping Systems  

E-Print Network (OSTI)

Gary Phetteplace August 1995 Optimal Design of Piping Systems for District Heating CRRELREPORT95 First, a method for determining the optimal size for a single pipe segment in a district heating system be feasible for designing the piping networks for district heating systems of moderate size, and its major

346

STATEMENT OF CONSIDERATIONS REQUEST BY NEW YORK STATE ELECTRIC & GAS CORPORATION  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NEW YORK STATE ELECTRIC & GAS CORPORATION NEW YORK STATE ELECTRIC & GAS CORPORATION (NYSEG) FOR AN ADVANCE WAIVER OF DOMESTIC AND FOREIGN INVENTION RIGHTS UNDER COOPERATIVE AGREEMENT NO. DE-FC22-92PC-92642, W(A)-93-016, CH-0773 NYSEG was awarded this cooperative agreement under the fourth round of the Innovative Clean Coal Technology Program pursuant to P.L. 101-512 to demonstrate a combination of cost effective emission reduction and efficiency improvement technolo- gies including: Saarberg-Holter Umwelltechnik's (S-H-U) advanced SO2 scrubber technology which uses formic acid enhancement and cocurrent/countercurrent open spray tower absorber design; Stebbins Engineering's tile-lined split module absorber construction; NOxOUT injection and air combustion modeling technology and implementation for NOx control; and heat pipe air heater technology to increase energy

347

In-Line Fluid Analysis Technology - Available Technologies ...  

Computers & Electronics; Manufacturing & Warehousing; Oil & Gas; Brochure(s) In-Line Fluid Analysis Brochure (pdf) Enabled by the Office ...

348

Valve for gas centrifuges  

DOE Patents (OSTI)

The invention is a pneumatically operated valve assembly for simultaneously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two of the lines so closed. The valve assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.

Hahs, Charles A. (Oak Ridge, TN); Burbage, Charles H. (Oak Ridge, TN)

1984-01-01T23:59:59.000Z

349

Air entrainment in transient flows in closed water pipes: a two-layer approach  

E-Print Network (OSTI)

In this paper, we first construct a model for transient free surface flows that takes into account the air entrainment by a sytem of 4 partial differential equations. We derive it by taking averaged values of gas and fluid velocities on the cross surface flow in the Euler equations (incompressible for the fluid and compressible for the gas). Then, we propose a mathematical kinetic interpretation of this system to finally construct a well-balanced kinetic scheme having the properties of conserving the still water steady state and possesing an energy. Finally, numerical tests on closed uniforms water pipes are performed and discussed.

Bourdarias, Christian; Gerbi, Stéphane

2009-01-01T23:59:59.000Z

350

Atomic gas temperature in a nonequilibrium high-intensity discharge lamp determined from the red wing of the resonance mercury line 254 nm  

Science Conference Proceedings (OSTI)

For developing low-wattage high intensity discharge (HID) lamps, a better understanding of the relatively unexplored nonequilibrium phenomena is essential. This needs interpretation of diagnostic results by methods free from equilibrium assumptions. In this paper, the atomic temperature is determined from the simulation of a quasistatic broadened resonance line by distinguishing between atomic temperature and excitation temperature in the equation of radiative transfer. The proposed method is applied to the red wing of the resonance mercury line 254 nm emitted from a HID lamp working on ac. The experimental results show severe deviation from local thermodynamic equilibrium. More than one thousand degrees difference was obtained between atomic and electron temperatures at the maximum current phase.

Drakakis, E. [Technological Educational Institute, Department of Electrical Engineering, 71004 Heraklion (Greece); Karabourniotis, D. [Institute of Plasma Physics, Department of Physics, University of Crete, 71003 Heraklion (Greece)

2012-09-01T23:59:59.000Z

351

Measurement of polyethylene pipe parameters during an ocean deployment. Final report  

DOE Green Energy (OSTI)

Data were acquired on the behavior of the polyethylene upwelling pipe for the GRI/DOE Marine Biomass Biological Test Farm during several phases of pipe assembly and ocean towing and deployment. The pipe is nominally 28 in O.D., 1400 feet long with wall thicknesses of 0.9 and 1.75 inches. The entire effort was conducted over a period of six weeks and was implemented on a strictly non-interference basis with the main Biomass Program. Three types of data were acquired during shore and ocean based operations conducted in the southern California area during the period from 15 September-27 September 1978. Axial strain data were obtained from two rows of 15 transducers each, separated circumferentially by 90/sup 0/ and distributed along the entire length of the pipe. Photographic data were also acquired from helicopter, boat and shore stationed cameras. The third type of data acquired were lowering line tension measurements made during the second successful deployment operation.

Hoppmann, R. F.; Ritchie, P. L.

1978-11-15T23:59:59.000Z

352

Testing of a sodium heat pipe  

SciTech Connect

The operation of a heat pipe with both thermal radiation and convection heat rejection has been experimentally examined. The thermal radiation heat rejection conditions are similar to those which would be experienced in a space environment. The experimental results show good agreement with the analytical model. 3 refs., 2 figs.

Holtz, R.E.

1991-01-01T23:59:59.000Z

353

Silicon heat pipes for cooling electronics  

SciTech Connect

The increasing power density of integrated circuits (ICs) is creating the need for improvements in systems for transferring heat away from the chip. In earlier investigations, diamond films were used to conduct heat from ICs and spread the energy across a heat sink. The authors` investigation has indicated that a 635 {mu}m (25 mil) thick silicon substrate with embedded heat pipes could perform this task better than a diamond film. From their study, it appears that the development of a heat-pipe heat-spreading system is both technically and commercially feasible. The major challenge for this heat-spreading system is to develop an effective wick structure to transport liquid to the heated area beneath the chip. This paper discusses the crucial design parameters for this heat-pipe system, such as the required wick properties, the material compatibility issues, and the thermal characteristics of the system. The paper also provides results from some recent experimental activities at Sandia to develop these heat-pipe heat spreader systems.

Adkins, D.R.; Shen, D.S.; Palmer, D.W.; Tuck, M.R.

1994-12-31T23:59:59.000Z

354

ASBESTOS PIPE-INSULATION REMOVAL ROBOT SYSTEM  

SciTech Connect

This final topical report details the development, experimentation and field-testing activities for a robotic asbestos pipe-insulation removal robot system developed for use within the DOE's weapon complex as part of their ER and WM program, as well as in industrial abatement. The engineering development, regulatory compliance, cost-benefit and field-trial experiences gathered through this program are summarized.

Unknown

2000-09-15T23:59:59.000Z

355

Buried Pipe Condition Assessment with Instrumented Vehicles  

Science Conference Proceedings (OSTI)

This report describes the evaluation of two technologies for the examination of buried piping in nuclear power plants. As part of this program, the electromagnetic and ultrasonic instrumented vehicles made by Hydroscope and Ucisco were used to examine two buried pipelines at the Palo Verde Nuclear Station.

2003-11-25T23:59:59.000Z

356

Passive ice freezing-releasing heat pipe  

DOE Patents (OSTI)

A heat pipe device has been developed which permits completely passive ice formation and periodic release of ice without requiring the ambient temperature to rise above the melting point of water. This passive design enables the maximum amount of cooling capacity to be stored in the tank.

Gorski, Anthony J. (Lemont, IL); Schertz, William W. (Batavia, IL)

1982-01-01T23:59:59.000Z

357

Heat pipe technology development for high temperature space radiator applications  

SciTech Connect

Technology requirements for heat pipe radiators, potentially among the lightest weight systems for space power applications, include flexible elements, and improved specific radiator performance(kg/kW). For these applications a flexible heat pipe capable of continuous operation through an angle of 180/sup 0/ has been demonstrated. The effect of bend angle on the heat pipe temperature distribution is reviewed. An analysis of lightweight membrane heat pipe radiators that use surface tension forces for fluid containment has been conducted. The design analysis of these lightweight heat pipes is described and a potential application in heat rejection systems for space nuclear power plants outlined.

Merrigan, M.A.; Keddy, E.S.; Sena, J.T.; Elder, M.G.

1984-01-01T23:59:59.000Z

358

Fossil Plant High-Energy Piping Damage: Theory and Practice  

Science Conference Proceedings (OSTI)

Condition assessment programs for high-energy piping systems are often a major aspect of a fossil utilitys inspection and maintenance program. In the past 30 years, a number of major failures of fossil high-energy piping have been associated with flow-accelerated corrosion (FAC) of feedwater piping, creep failures of longitudinal seam-welded hot reheat and main steam piping, and corrosion fatigue/thermal failures of cold reheat steam piping. In addition to these well-documented failures, most utilities e...

2008-03-27T23:59:59.000Z

359

AWSWAH - the heat pipe solar water heater  

Science Conference Proceedings (OSTI)

An all weather heat pipe solar water heater (AWSWAH) comprising a collector of 4 m/sup 2/ (43 ft/sup 2/) and a low profile water tank of 160 liters (42 gal.) was developed. A single heat pipe consisting of 30 risers and two manifolds in the evaporator and a spiral condenser was incorporated into the AWSWAH. Condensate metering was done by synthetic fiber wicks. The AWSWAH was tested alongside two conventional solar water heaters of identical dimensions, an open loop system and a closed loop system. It was found that the AWSWAH was an average of 50% more effective than the open system in the temperature range 30-90 /sup 0/C (86-194 /sup 0/F). The closed loop system was the least efficient of the three systems.

Akyurt, M.

1986-01-01T23:59:59.000Z

360

Stainless steel submerged arc weld fusion line toughness  

SciTech Connect

This effort evaluated the fracture toughness of austenitic steel submerged-arc weld (SAW) fusion lines. The incentive was to explain why cracks grow into the fusion line in many pipe tests conducted with cracks initially centered in SAWS. The concern was that the fusion line may have a lower toughness than the SAW. It was found that the fusion line, Ji. was greater than the SAW toughness but much less than the base metal. Of greater importance may be that the crack growth resistance (JD-R) of the fusion line appeared to reach a steady-state value, while the SAW had a continually increasing JD-R curve. This explains why the cracks eventually turn to the fusion line in the pipe experiments. A method of incorporating these results would be to use the weld metal J-R curve up to the fusion-line steady-state J value. These results may be more important to LBB analyses than the ASME flaw evaluation procedures, since there is more crack growth with through-wall cracks in LBB analyses than for surface cracks in pipe flaw evaluations.

Rosenfield, A.R.; Held, P.R.; Wilkowski, G.M. [Battelle, Columbus, OH (United States)

1995-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Safety implications associated with in-plant pressurized gas storage and distribution systems in nuclear power plants  

SciTech Connect

Storage and handling of compressed gases at nuclear power plants were studied to identify any potential safety hazards. Gases investigated were air, acetylene, carbon dioxide, chlorine, Halon, hydrogen, nitrogen, oxygen, propane, and sulfur hexaflouride. Physical properties of the gases were reviewed as were applicable industrial codes and standards. Incidents involving pressurized gases in general industry and in the nuclear industry were studied. In this report general hazards such as missiles from ruptures, rocketing of cylinders, pipe whipping, asphyxiation, and toxicity are discussed. Even though some serious injuries and deaths over the years have occurred in industries handling and using pressurized gases, the industrial codes, standards, practices, and procedures are very comprehensive. The most important safety consideration in handling gases is the serious enforcement of these well-known and established methods. Recommendations are made concerning compressed gas cylinder missiles, hydrogen line ruptures or leaks, and identification of lines and equipment.

Guymon, R.H.; Casto, W.R.; Compere, E.L.

1985-05-01T23:59:59.000Z

362

Electrically heated liquid tank employing heat pipe heat transfer means  

SciTech Connect

The heating apparatus for applying heat to the interior of a chamber includes a modular, removable, electrical, heat-producing unit and a heat pipe mountable in a wall of the chamber with one end of the pipe arranged to receive heat from the electrical heat producing unit exterior of the housing and with another end of the pipe constructed and arranged to apply heat to the medium within the chamber. The heat pipe has high conductivity with a low temperature differential between the ends thereof and the heat producing unit includes an electric coil positioned about and removably secured to the one end of the heat pipe. The electric coil is embedded in a high thermal conducitivity, low electrical conductivity filler material which is surrounded by a low thermal conductivity insulating jacket and which is received around a metal core member which is removably secured to the one end of the heat pipe.

Shutt, J.R.

1978-12-26T23:59:59.000Z

363

Review of liquid metal heat pipe work at Los Alamos  

SciTech Connect

A survey of space-power related liquid metal heat pipe work at Los Alamos National Laboratory is presented. Heat pipe development at Los Alamos has been on-going since 1963. Heat pipes were initially developed for thermionic nuclear-electrical power production in space. Since then Los Alamos has developed liquid metal heat pipes for numerous applications related to high temperature systems in both the space and terrestrial environments. Some of these applications include thermionic electrical generators, thermoelectric energy conversion (both in-core and direct radiation), thermal energy storage, hypersonic vehicle leading edge cooling, and heat pipe vapor laser cells. Some of the work performed at Los Alamos has been documented in internal reports that are often little-known. A representative description and summary of progress in space-related liquid metal heat pipe technology is provided followed by a reference section citing sources where these works may be found. 53 refs.

Reid, R.S.; Merrigan, M.A.; Sena, J.T.

1990-01-01T23:59:59.000Z

364

Pipe overpack container for transuranic waste storage and shipment  

Science Conference Proceedings (OSTI)

A Pipe Overpack Container is described for transuranic waste storage and shipment. The system consists of a vented pipe component which is positioned in a vented, insulated 55 gallon steel drum. Both the vented pipe component and the insulated drum are capable of being secured to prevent the contents from leaving the vessel. The vented pipe component is constructed of 1/4 inch stainless steel to provide radiation shielding, thus allowing shipment having high Americium-241 content. Several Pipe Overpack Containers are then positioned in a type B, Nuclear Regulatory Commission (NRC) approved, container. In the current embodiment, a TRUPACT-II container was employed and a maximum of fourteen Pipe Overpack Containers were placed in the TRUPACT-II. The combination received NRC approval for the shipment and storage of transuranic waste.

Geinitz, R.R.; Thorp, D.T.; Rivera, M.A.

1999-12-07T23:59:59.000Z

365

Pipe overpack container for trasuranic waste storage and shipment  

DOE Patents (OSTI)

A Pipe Overpack Container for transuranic waste storage and shipment. The system consists of a vented pipe component which is positioned in a vented, insulated 55 gallon steel drum. Both the vented pipe component and the insulated drum are capable of being secured to prevent the contents from leaving the vessel. The vented pipe component is constructed of 1/4 inch stainless steel to provide radiation shielding. Thus, allowing shipment having high Americium-241 content. Several Pipe Overpack Containers are then positioned in a type B, Nuclear Regulatory Commission (NRC) approved, container. In the current embodiment, a TRUPACT-II container was employed and a maximum of fourteen Pipe Overpack Containers were placed in the TRUPACT-II. The combination received NRC approval for the shipment and storage of transuranic waste.

Geinitz, Richard R. (Arvada, CO); Thorp, Donald T. (Broomfield, CO); Rivera, Michael A. (Boulder, CO)

1999-01-01T23:59:59.000Z

366

Heat Pipe Technology for Energy Conservation in the Process Industry  

E-Print Network (OSTI)

Many applications for heat pipe technology have emerged in the relatively short time this technology has been known. Heat pipes incorporated in heat exchangers have been used in tens of thousands of successful heat recovery systems. These systems range from residential and commercial air-to-air heat exchangers to giant air preheaters for the process and utility industries. The heat pipe offers a unique, efficient heat transfer device that can recover valuable thermal energy resulting in reduced equipment and operating costs. Q-dot is the world leader in heat pipe technology and we have applied our expertise in engineering heat recovery products for the process industry. This paper discusses two such products, the heat pipe air preheater and waste heat recovery boiler. These heat pipe products have been used in many successful installations all over the world and some important, distinctive features of these systems will be presented.

Price, B. L. Jr.

1985-05-01T23:59:59.000Z

367

Acoustic cross-correlation flowmeter for solid-gas flow  

DOE Patents (OSTI)

Apparatus for measuring particle velocity in a solid-gas flow within a pipe includes: first and second transmitting transducers for transmitting first and second ultrasonic signals into the pipe at first and second locations, respectively, along the pipe; an acoustic decoupler, positioned between said first and second transmitting transducers, for acoustically isolating said first and second signals from one another; first and second detecting transducers for detecting said first and second signals and for generating first and second detected signals; and means for cross-correlating said first and second output signals.

Sheen, S.H.; Raptis, A.C.

1984-05-14T23:59:59.000Z

368

Integrated manufacturing system of high-pressure FRP pipes  

Science Conference Proceedings (OSTI)

In order to realise industrialised manufacturing of epoxy FRP pipes, the manufacturing system which can accomplish winding, internal heating curing and extraction processes by only one machine tool was developed. The winding motion control is undertaken ... Keywords: FEM, FRP pipes, blowing control, cooling control, curing control, embedded controllers, fibreglass reinforced plastics, finite element method, high-pressure pipes, integrated manufacturing, internal heating curing, motion control, simulation, thermochemical modelling, winding

Bo You; Jiazhong Xu; Xiongjian Wang

2007-11-01T23:59:59.000Z

369

Balance of Plant Corrosion -- The Buried Pipe Reference Guide  

Science Conference Proceedings (OSTI)

In 2007, EPRI conducted two workshops in which the integrity of buried pipes was identified as a significant issue for nuclear power plants. One result of the workshops was that EPRI was asked to sponsor development of a recommendations document to help plant engineers prevent and mitigate degradation and leaks in buried pipes. EPRI report 1016456, Recommendations for an Effective Program to Control the Degradation of Buried and Underground Piping and Tanks, was prepared to address that need. In 2010, EP...

2010-12-20T23:59:59.000Z

370

Remediation of Embedded Piping: Trojan Nuclear Plant Decommissioning Experience  

Science Conference Proceedings (OSTI)

Characterization, decontamination, survey, and/or removal of contaminated embedded piping can have a substantial financial impact on decommissioning projects, depending on the project approach. This report presents a discussion of the Trojan Embedded Pipe Remediation Project (EPRP) activities, including categorization and characterization of affected piping, modeling for the proposed contamination acceptance criteria, and evaluations of various decontamination and survey techniques. The report also descr...

2000-10-19T23:59:59.000Z

371

Fuel injection staged sectoral combustor for burning low-BTU fuel gas  

SciTech Connect

A high-temperature combustor for burning low-BTU coal gas in a gas turbine is described. The combustor comprises a plurality of individual combustor chambers. Each combustor chamber has a main burning zone and a pilot burning zone. A pipe for the low-BTU coal gas is connected to the upstream end of the pilot burning zone; this pipe surrounds a liquid fuel source and is in turn surrounded by an air supply pipe; swirling means are provided between the liquid fuel source and the coal gas pipe and between the gas pipe and the air pipe. Additional preheated air is provided by counter-current coolant air in passages formed by a double wall arrangement of the walls of the main burning zone communicating with passages of a double wall arrangement of the pilot burning zone; this preheated air is turned at the upstream end of the pilot burning zone through swirlers to mix with the original gas and air input (and the liquid fuel input when used) to provide more efficient combustion. One or more fuel injection stages (second stages) are provided for direct input of coal gas into the main burning zone. The countercurrent air coolant passages are connected to swirlers surrounding the input from each second stage to provide additional oxidant.

Vogt, Robert L. (Schenectady, NY)

1981-01-01T23:59:59.000Z

372

Fuel injection staged sectoral combustor for burning low-BTU fuel gas  

SciTech Connect

A high-temperature combustor for burning low-BTU coal gas in a gas turbine is described. The combustor comprises a plurality of individual combustor chambers. Each combustor chamber has a main burning zone and a pilot burning zone. A pipe for the low-BTU coal gas is connected to the upstream end of the pilot burning zone: this pipe surrounds a liquid fuel source and is in turn surrounded by an air supply pipe: swirling means are provided between the liquid fuel source and the coal gas pipe and between the gas pipe and the air pipe. Additional preheated air is provided by counter-current coolant air in passages formed by a double wall arrangement of the walls of the main burning zone communicating with passages of a double wall arrangement of the pilot burning zone: this preheated air is turned at the upstream end of the pilot burning zone through swirlers to mix with the original gas and air input (and the liquid fuel input when used) to provide more efficient combustion. One or more fuel injection stages (second stages) are provided for direct input of coal gas into the main burning zone. The countercurrent air coolant passages are connected to swirlers surrounding the input from each second stage to provide additional oxidant.

Vogt, Robert L. (Schenectady, NY)

1985-02-12T23:59:59.000Z

373

Post-trenching plow cuts ditch under offshore line  

Science Conference Proceedings (OSTI)

In a 15-day operation, a 68-ton, 60-ft-long underwater post-trenching plow successfully cut an approximately 4-ft-deep protective trench under the 23-mile-long, 24-in.-diameter gas-transmission pipeline connecting Esso Australia's Snapper A platform to shore in Australia's Bass Strait. Scale-model tests had provided towing-force data and proved the feasibility of split, butterfly-type shares that wrap around the pipe. A yoke on the pull-cable attachment, which places the pulling points on the shares rather than on the plow body, permitted the use of a much lighter body, thus saving about 30 tons of steel. Underwater television cameras monitored the plow's instrumentation panel, which received data on horizontal and vertical loads, the position of the shares, cutting depth and forward speed, and pull-cable horizontal and vertical departure angles from the plow. The soils encountered along the line included high-water-content quicksand, firm sand, cemented sandstone, and hard limestone.

Brown, R.J.

1980-06-01T23:59:59.000Z

374

Sodium and lithium corrosion in molybdenum heat pipes  

SciTech Connect

Sodium and lithium corrosin in molybdenum heat pipes has been shown to be impurity dependent rather than solubility dependent. Impurities represent the major contributors to corrosion in the heat pipes tested. Our experiments have shown no evidence of direct solution of molybdenum by either sodium or lithium. Analysis has suggested that a critical concentration of impurities is required to initiate corrosion. Thus it appears that corrosion in Mo/Na and Mo/Li heat pipes can be controlled if impurity concentration can be limited by removal of impurities from the working fluid and heat pipe components prior to operation or by internal gettering during operation.

Lundberg, L.B.; Merrigan, M.A.

1984-01-01T23:59:59.000Z

375

Influence of Feeding Flow and Shrinkage Pipe Formation on ...  

Science Conference Proceedings (OSTI)

Presentation Title, Influence of Feeding Flow and Shrinkage Pipe Formation on ... CFD–Based Modelling on Interfacial Heat Transfer for Water Quenching.

376

Polyethylene Pipe Failure in the Arctic - Programmaster.org  

Science Conference Proceedings (OSTI)

In the current study, a new high density polyethylene (HDPE) pipe in the Arctic region of ... Heat Tint Effects on General Corrosion Resistance of Stainless Steels .

377

Nondestructive Evaluation: Ultrasonic Examination Techniques for High Density Polyethylene Pipes  

Science Conference Proceedings (OSTI)

High density polyethylene (HDPE) pipe has been used as a replacement material for buried carbon steel pipe in non-safety-related systems. Using the current butt fusion procedure that uses heat and pressure to melt and join two sections of plastic pipe, concerns have been raised that would indicate that the presence of decreased bond strength when the welding parameters for fusion set forth by the plastic pipe industry were not followed. Currently two utilities, Ameren UE at Callaway and Duke-Energy at Ca...

2011-11-15T23:59:59.000Z

378

ID Cladding of Pipe Using Resistance Seam Processing  

Science Conference Proceedings (OSTI)

Recently, Edison Welding Institute as developed a new technology for cladding of such pipe. This technology incorporates a resistance seam welding approach,

379

International Piping Integrity Research Group (IPIRG) Program. Final report  

SciTech Connect

This is the final report of the International Piping Integrity Research Group (IPIRG) Program. The IPIRG Program was an international group program managed by the U.S. Nuclear Regulatory Commission and funded by a consortium of organizations from nine nations: Canada, France, Italy, Japan, Sweden, Switzerland, Taiwan, the United Kingdom, and the United States. The program objective was to develop data needed to verify engineering methods for assessing the integrity of circumferentially-cracked nuclear power plant piping. The primary focus was an experimental task that investigated the behavior of circumferentially flawed piping systems subjected to high-rate loadings typical of seismic events. To accomplish these objectives a pipe system fabricated as an expansion loop with over 30 meters of 16-inch diameter pipe and five long radius elbows was constructed. Five dynamic, cyclic, flawed piping experiments were conducted using this facility. This report: (1) provides background information on leak-before-break and flaw evaluation procedures for piping, (2) summarizes technical results of the program, (3) gives a relatively detailed assessment of the results from the pipe fracture experiments and complementary analyses, and (4) summarizes advances in the state-of-the-art of pipe fracture technology resulting from the IPIRG program.

Wilkowski, G.; Schmidt, R.; Scott, P. [and others

1997-06-01T23:59:59.000Z

380

Magnetohydrodynamic power generation, electromagnetic pumps, heat pipes, and thermionic convertors  

DOE Green Energy (OSTI)

The basic principles of operation, components, and design of MHD generators, electromagnetic pumps, heat pipes and thermionic converters are described. 66 references. (WHK)

Pierson, E.S.; Bonyhady, K.A.; Dunn, P.F.; Nathenson, R.D.; Uherka, K.L.

1984-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Toward Active Monitoring of Piping Using Ultrasonic Guided Waves  

Science Conference Proceedings (OSTI)

Piping in nuclear power plants is exposed to severe environmental conditions so that it is very susceptible to failure caused by the growth of defects. Thus

Joon?Soo Park; Young H. Kim; Sung?Jin Song; Jae?Hee Kim; Heung?Seop Eom; Kwang?Hee Im

2004-01-01T23:59:59.000Z

382

NETL: News Release - Pipe Locating Sensor Could Help Prevent...  

NLE Websites -- All DOE Office Websites (Extended Search)

Ceramic, Plastic and Metallic Objects DES PLAINS, IL - Successful early tests of a pipeline sensor that locates plastic, ceramic and metallic underground pipes could help reduce...

383

FEM Analysis of Pipe Reduction Forming Process for Increasing of ...  

Science Conference Proceedings (OSTI)

As a method of reducing a pipe to obtain a desired diameter, Kiuchi et al. propose a planetary ... Alloy Parts Heat Treatment Temperature Monitoring System.

384

Experimental and computational studies of loop heat pipes.  

E-Print Network (OSTI)

??Computational and experimental investigations of fluid flow and heat transfer aspects of loop heat pipes (LHPs) are presented in this thesis. The overall goal is… (more)

Atabaki, Nima.

2006-01-01T23:59:59.000Z

385

Fabrication, Filling, Sealing and Testing of Micro Heat Pipes.  

E-Print Network (OSTI)

??Micro heat pipes are small and passive heat transfer devices. Research is going on in its applications ranging from using them in high powered electronic… (more)

NADGAUDA, OMKAR

2006-01-01T23:59:59.000Z

386

Investigation of Unusual “Sharkskin” Corrosion in Drawn Copper Pipes  

Science Conference Proceedings (OSTI)

Alloy Parts Heat Treatment Temperature Monitoring System · Analysis of ... FEM Analysis of Pipe Reduction Forming Process for Increasing of Wall Thickness.

387

Natural Gas Weekly Update  

Gasoline and Diesel Fuel Update (EIA)

(MAOP). To address this issue, the NTSB asked PG&E to conduct an intensive records search to identify all the gas transmission lines that had not previously undergone a testing...

388

A DATA FUSION SYSTEM FOR THE NONDESTRUCTIVE EVALUATION OF NON-PIGGABLE PIPES  

SciTech Connect

The objectives of this research project are: (1) To design sensor data fusion algorithms that can synergistically combine defect related information from heterogeneous sensors used in gas pipeline inspection for reliably and accurately predicting the condition of the pipe-wall. (2) To develop efficient data management techniques for signals obtained during multisensor interrogation of a gas pipeline. During this reporting period, Rowan University fabricated test specimens with simulated defects for nondestructive evaluation (NDE); designed and developed two versions of a test platform for performing multi-sensor interrogation of test specimens under loaded conditions simulating pressurized gas pipelines; and performed acoustic emission (AE) NDE on the test specimens. The data resulting from this work will be employed for designing multi-sensor data fusion algorithms during the next reporting period.

Dr. Shreekanth Mandayam; Dr. Robi Polikar; Dr. John C. Chen

2003-06-01T23:59:59.000Z

389

A DATA FUSION SYSTEM FOR THE NONDESTRUCTIVE EVALUATION OF NON-PIGGABLE PIPES  

Science Conference Proceedings (OSTI)

The objectives of this research project are: (1) To design sensor data fusion algorithms that can synergistically combine defect related information from heterogeneous sensors used in gas pipeline inspection for reliably and accurately predicting the condition of the pipe-wall. (2) To develop efficient data management techniques for signals obtained during multisensor interrogation of a gas pipeline. During this reporting period, Rowan University designed, developed and exercised multisensor data fusion algorithms for identifying defect related information present in magnetic flux leakage, ultrasonic testing, thermal imaging and acoustic emission nondestructive evaluation signatures of a test-specimen suite representative of benign and anomalous indications in gas transmission pipelines. Specifically, the algorithms presented in the earlier reports were augmented to predict information related to defect depth (severity).

Shreekanth Mandayam; Robi Polikar; John C. Chen

2005-02-01T23:59:59.000Z

390

A Data Fusion System for the Nondestructive Evaluation of Non-Piggable Pipes  

Science Conference Proceedings (OSTI)

The objectives of this research project are: (1) To design sensor data fusion algorithms that can synergistically combine defect related information from heterogeneous sensors used in gas pipeline inspection for reliably and accurately predicting the condition of the pipe-wall; and (2) To develop efficient data management techniques for signals obtained during multisensor interrogation of a gas pipeline. This final report summarizes all research activities conducted by Rowan University during the project period. This includes the design and development of experimental validation test platforms, the design and development of data fusion algorithms for defect identification and sizing, and finally, the design and development of advanced visualization algorithms for the effective management of data resulting from multi-sensor interrogation of gas transmission pipelines.

Shreekanth Mandayam; Robi Polikar; John C. Chen

2006-02-01T23:59:59.000Z

391

Heat pipe with improved wick structures  

DOE Patents (OSTI)

An improved planar heat pipe wick structure having projections formed by micromachining processes. The projections form arrays of interlocking, semi-closed structures with multiple flow paths on the substrate. The projections also include overhanging caps at their tops to increase the capillary pumping action of the wick structure. The capped projections can be formed in stacked layers. Another layer of smaller, more closely spaced projections without caps can also be formed on the substrate in between the capped projections. Inexpensive materials such as Kovar can be used as substrates, and the projections can be formed by electrodepositing nickel through photoresist masks.

Benson, David A. (Albuquerque, NM); Robino, Charles V. (Albuquerque, NM); Palmer, David W. (Albuquerque, NM); Kravitz, Stanley H. (Placitas, NM)

2000-01-01T23:59:59.000Z

392

Performance correlations for high temperature potassium heat pipes  

SciTech Connect

Potassium heat pipes designed for operation at a nominal temperature of 775K have been developed for use in a heat pipe cooled reactor design. The heat pipes operate in a gravity assist mode with a maximum required power throughput of approximately 16 kW per heat pipe. Based on a series of sub-scale experiments with 2.12 and 3.2 cm diameter heat pipes the prototypic heat pipe diameter was set at 5.7 cm with a simple knurled wall wick used in the interests of mechanical simplicity. The performance levels required for this design had been demonstrated in prior work with gutter assisted wicks and emphasis in the present work was on the attainment of similar performance with a simplified wick structure. The wick structure used in the experiment consisted of a pattern of knurled grooves in the internal wall of the heat pipe. The knurl depth required for the planned heat pipe performance was determined by scaling of wick characteristic data from the sub-scale tests. These tests indicated that the maximum performance limits of the test heat pipes did not follow normal entrainment limit predictions for textured wall gravity assist heat pipes. Test data was therefore scaled to the prototype design based on the assumption that the performance was controlled by an entrainment parameter based on the liquid flow depth in the groove structure. This correlation provided a reasonable fit to the sub-scale test data and was used in scale up of the design from the 8.0 cm/sup 2/ cross section of the largest sub-scale heat pipe to the 25.5 cm/sup 2/ cross section prototype. Correlation of the model predictions with test data from the prototype is discussed.

Merrigan, M.A.; Keddy, E.S.; Sena, J.T.

1987-01-01T23:59:59.000Z

393

Development and Application of Insulated Drill Pipe for High Temperature, High Pressure Drilling  

Science Conference Proceedings (OSTI)

This project aimed to extend the insulated drill pipe (IDP) technology already demonstrated for geothermal drilling to HTHP drilling in deep gas reservoirs where temperatures are high enough to pose a threat to downhole equipment such as motors and electronics. The major components of the project were: a preliminary design; a market survey to assess industry needs and performance criteria; mechanical testing to verify strength and durability of IDP; and development of an inspection plan that would quantify the ability of various inspection techniques to detect flaws in assembled IDP. This report is a detailed description of those activities.

Tom Champness; Tony Worthen; John Finger

2008-12-31T23:59:59.000Z

394

Kentucky Transmission Line Siting Methodology  

Science Conference Proceedings (OSTI)

EPRI, in conjunction with Georgia Transmission Corporation (GTC) and Photo Science, Inc. (PSI), developed a standardized methodology for siting overhead electric transmission lines. EPRI report 1013080, EPRI-GTC Overhead Electric Transmission Line Siting Methodology, published February 2006, provides additional information. This methodology has been applied in Georgia and currently is being applied to projects in Kentucky by East Kentucky Power Cooperative and E.ON U.S. on behalf of Louisville Gas and El...

2007-12-18T23:59:59.000Z

395

The Use of Weld Overlays to Extend the Useful Life of Seam Welded High Energy Piping in Fossil Power Plants  

Science Conference Proceedings (OSTI)

Replacement of longitudinally welded reheat and main steam lines is very expensive and can result in extended outages. Inspection and re-inspection of such systems every few years is also expensive and time-consuming. An alternative to continued inspection or system replacement is weld overlay. This report provides the basis for weld overlay of one component, clamshell elbows. Weld overlay of other piping system components will build upon the technology developed in this program.

2001-02-28T23:59:59.000Z

396

SewerSnort: A drifting sensor for in situ Wastewater Collection System gas monitoring  

Science Conference Proceedings (OSTI)

Biochemical reactions that occur in sewer pipes produce a considerable amount of hydrogen sulfide gas (H"2S corrosive and poisonous), methane gas (CH"4 explosive and a major climate change contributor), carbon dioxide (CO"2 a major climate change contributor), ... Keywords: Biochemical process, Electrochemical gas sensor, Mobile sensing, Received signal strength indicator based localization, Wastewater Collection System

Jung Soo Lim, Jihyoung Kim, Jonathan Friedman, Uichin Lee, Luiz Vieira, Diego Rosso, Mario Gerla, Mani B. Srivastava

2013-06-01T23:59:59.000Z

397

Low Cost High Performance Generator Technology Program. Volume 5. Heat pipe topical, appendices  

SciTech Connect

Work performed by Dynatherm Corporation for Teledyne Isotopes during a program entitled ''Heat Pipe Fabrication, Associated Technical Support and Reporting'' is reported. The program was initiated on November 29, 1972; the main objectives were accomplished with the delivery of the heat pipes for the HPG. Life testing of selected heat pipe specimens is continuing to and beyond the present date. The program consisted of the following tasks: Heat Pipe Development of Process Definition; Prototype Heat Pipes for Fin Segment Test; HPG Heat Pipe Fabrication and Testing; Controlled Heat Pipe Life Test; and Heat Pipe Film Coefficient Determination. (TFD)

1975-07-01T23:59:59.000Z

398

Low Cost High Performance Generator Technology Program. Volume 5. Heat pipe topical, appendices  

DOE Green Energy (OSTI)

Work performed by Dynatherm Corporation for Teledyne Isotopes during a program entitled ''Heat Pipe Fabrication, Associated Technical Support and Reporting'' is reported. The program was initiated on November 29, 1972; the main objectives were accomplished with the delivery of the heat pipes for the HPG. Life testing of selected heat pipe specimens is continuing to and beyond the present date. The program consisted of the following tasks: Heat Pipe Development of Process Definition; Prototype Heat Pipes for Fin Segment Test; HPG Heat Pipe Fabrication and Testing; Controlled Heat Pipe Life Test; and Heat Pipe Film Coefficient Determination. (TFD)

Not Available

1975-07-01T23:59:59.000Z

399

The Advantages of HDPE Piping & Vaults in the  

E-Print Network (OSTI)

First in the world to produce 1600mm PE pipes Production of district heating pipes starts 1984 & telecom · Waste water treatment · House drainage · Under ground ventilation · Renovation · District heating & cooling · Special constructions · Marine intakes and outfalls · Welding, extrusion and blown

400

Integrated heat pipe-thermal storage system performance evaluation  

SciTech Connect

Performance verification tests of an integrated heat pipe-thermal energy storage system have been conducted. This system is being developed as a part of an Organic Rankine Cycle-Solar Dynamic Power System (ORC-SDPS) receiver for future space stations. The integrated system consists of potassium heat pipe elements that incorporate thermal energy storage (TES) canisters within the vapor space along with an organic fluid (toluene) heater tube used as the condenser region of the heat pipe. During the insolation period of the earth orbit, solar energy is delivered to the surface of the heat pipe elements of the ORC-SDPS receiver and is internally transferred by the potassium vapor for use and storage. Part of the thermal energy is delivered to the heater tube and the balance is stored in the TES units. During the eclipse period of the orbit, the stored energy in the TES units is transferred by the potassium vapor to the toluene heater tube. A developmental heat pipe element was fabricated that employs axial arteries and a distribution wick connecting the wicked TES units and the heater to the solar insolation surface of the heat pipe. Tests were conducted to verify the heat pipe operation and to evaluate the heat pipe/TES units/heater tube operation by interfacing the heater unit to a heat exchanger.

Keddy, E.; Sena, J.T.; Merrigan, M.

1987-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Liquid metal heat pipe behavior under transient cooling and heating  

SciTech Connect

This paper describes the results of an experimental investigation of the transient behavior of a liquid metal heat pipe. A 0.457 m long, screen-wick, sodium heat pipe with 0.0127 m outer diameter was tested in sodium loop facility. The heat pipe reversed under a pulse heat load applied at the condenser. The time at which the heat pipe reversed was dependent of the heat pipe properties, the sodium loop flow rate and heating conditions at the condenser. The start-up and the operational shut-down by forced cooling of the condenser were also studied. During the start-up process, at least part of the heat pipe was active. The active region extended gradually down to the end of the condenser until all working fluid in the heat pipe was molten. With forced cooling at the condenser, the heat pipe approached its heat transport limit before section of the condenser became frozen. The measured heat transport limit was in agreement with the theoretical value. 5 refs.

Nguyen, H.X.; Hahn, T.O.; Hahn, O.J.; Chow, L.C.; Tagavi, K.A.; Morgan, M.J. (Kentucky, University, Lexington (United States) USAF, Wright Laboratory, Wright-Patterson AFB, OH (United States))

1992-01-01T23:59:59.000Z

402

October 15, 2001 PRE-INSULATED UNDERGROUND PIPE FOR STEAM  

E-Print Network (OSTI)

SERVICE PART 1 ­ GENERAL 1.01 SUMMARY Underground steam and condensate distribution systems includingOctober 15, 2001 02558-1 PRE-INSULATED UNDERGROUND PIPE FOR STEAM AND CONDENSATE SERVICE CONSTRUCTION STANDARD SPECIFICATION SECTION 02558 PRE-INSULATED UNDERGROUND PIPE FOR STEAM AND CONDENSATE

403

Pulsed gas laser  

DOE Patents (OSTI)

A pulsed gas laser is constituted by Blumlein circuits wherein space metal plates function both as capacitors and transmission lines coupling high frequency oscillations to a gas filled laser tube. The tube itself is formed by spaced metal side walls which function as connections to the electrodes to provide for a high frequency, high voltage discharge in the tube to cause the gas to lase. Also shown is a spark gap switch having structural features permitting a long life.

Anderson, Louis W. (Madison, WI); Fitzsimmons, William A. (Madison, WI)

1978-01-01T23:59:59.000Z

404

LNG delivery system for gas powered vehicles  

Science Conference Proceedings (OSTI)

This patent describes a natural gas delivery system. It comprises a first vehicle mounted tank for storing liquid natural gas and natural gas vapor; a second vehicle mounted tank for storing liquid natural gas and natural gas vapor; a use line connected to the first and second tanks for receiving natural gas from the first and second tanks and delivering natural gas vapor to the use device on the vehicle and means for pressurizing the natural gas in the use line; means for selecting one of the first or second tanks to deliver natural gas to the use line; and means for overriding the selecting means to deliver natural gas vapor to the use line from either of the tanks in response to detecting a pressure rise therein which exceeds a preselected maximum.

Nesser, T.A.; Hedegard, K.W.

1992-07-07T23:59:59.000Z

405

Natural gas pipeline technology overview.  

Science Conference Proceedings (OSTI)

The United States relies on natural gas for one-quarter of its energy needs. In 2001 alone, the nation consumed 21.5 trillion cubic feet of natural gas. A large portion of natural gas pipeline capacity within the United States is directed from major production areas in Texas and Louisiana, Wyoming, and other states to markets in the western, eastern, and midwestern regions of the country. In the past 10 years, increasing levels of gas from Canada have also been brought into these markets (EIA 2007). The United States has several major natural gas production basins and an extensive natural gas pipeline network, with almost 95% of U.S. natural gas imports coming from Canada. At present, the gas pipeline infrastructure is more developed between Canada and the United States than between Mexico and the United States. Gas flows from Canada to the United States through several major pipelines feeding U.S. markets in the Midwest, Northeast, Pacific Northwest, and California. Some key examples are the Alliance Pipeline, the Northern Border Pipeline, the Maritimes & Northeast Pipeline, the TransCanada Pipeline System, and Westcoast Energy pipelines. Major connections join Texas and northeastern Mexico, with additional connections to Arizona and between California and Baja California, Mexico (INGAA 2007). Of the natural gas consumed in the United States, 85% is produced domestically. Figure 1.1-1 shows the complex North American natural gas network. The pipeline transmission system--the 'interstate highway' for natural gas--consists of 180,000 miles of high-strength steel pipe varying in diameter, normally between 30 and 36 inches in diameter. The primary function of the transmission pipeline company is to move huge amounts of natural gas thousands of miles from producing regions to local natural gas utility delivery points. These delivery points, called 'city gate stations', are usually owned by distribution companies, although some are owned by transmission companies. Compressor stations at required distances boost the pressure that is lost through friction as the gas moves through the steel pipes (EPA 2000). The natural gas system is generally described in terms of production, processing and purification, transmission and storage, and distribution (NaturalGas.org 2004b). Figure 1.1-2 shows a schematic of the system through transmission. This report focuses on the transmission pipeline, compressor stations, and city gates.

Folga, S. M.; Decision and Information Sciences

2007-11-01T23:59:59.000Z

406

Surveillance Guide - OPS 9.18 Equipment and Piping Labeling  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EQUIPMENT AND PIPING LABELING EQUIPMENT AND PIPING LABELING 1.0 Objective The objective of this surveillance is to verify that facility equipment and piping are labeled in a manner such that facility personnel are able to positively identify equipment they operate. This surveillance provides a basis for evaluating the effectiveness of the contractor's program for labeling equipment and piping and for establishing compliance with DOE requirements. 2.0 References 2.1 DOE 5480.19, Conduct of Operations Requirements for DOE Facilities 2.2 DOE-STD-1044-93, Guide to Good Practices for Equipment and Piping Labeling 3.0 Requirements Implemented This surveillance is conducted to implement requirements of the Functions, Requirements and Authorities Manual, Section 20,

407

CRAD, Equipment and Piping Labeling Assessment Plan | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Equipment and Piping Labeling Assessment Plan Equipment and Piping Labeling Assessment Plan CRAD, Equipment and Piping Labeling Assessment Plan Performance Objective: To verify that facility equipment and piping are labeled in a manner such that facility personnel are able to positively identify equipment they operate. To ensure that an effective labeling program is in effect to reduce operator and maintenance errors from incorrect identification of equipment, to increase training effectiveness by tracing the actual facility system as opposed to tracing its schematic, and to reduce personnel exposure to radiation and hazardous materials. This assessment provides a basis for evaluating the effectiveness of the contractor's program for labeling equipment and piping and for establishing compliance with DOE requirements.

408

Analysis of the transient compressible vapor flow in heat pipe  

SciTech Connect

The transient compressible one-dimensional vapor flow dynamics in a heat pipe is modeled. The numerical results are obtained by using the implicit non-iterative Beam-Warming finite difference method. The model is tested for simulated heat pipe vapor flow and actual vapor flow in cylindrical heat pipes. A good comparison of the present transient results for the simulated heat pipe vapor flow with the previous results of a two-dimensional numerical model is achieved and the steady state results are in agreement with the existing experimental data. The transient behavior of the vapor flow under subsonic, sonic, and supersonic speeds and high mass flow rates are successfully predicted. The one-dimensional model also describes the vapor flow dynamics in cylindrical heat pipes at high temperatures.

Jang, J.H.; Faghri, A. [Wright State Univ., Dayton, OH (United States); Chang, W.S. [Wright Research and Development Center, Wright-Patterson, OH (United States)

1989-07-01T23:59:59.000Z

409

Long titanium heat pipes for high-temperature space radiators  

SciTech Connect

Titanium heat pipes are being developed to provide light weight, reliable heat rejection devices as an alternate radiator design for the Space Reactor Power System (SP-100). The radiator design includes 360 heat pipes, each of which is 5.2 m long and dissipates 3 kW of power at 775 K. The radiator heat pipes use potassium as the working fluid, have two screen arteries for fluid return, a roughened surface distributive wicking system, and a D-shaped cross-section container configuration. A prototype titanium heat pipe, 5.5-m long, has been fabricated and tested in space-simulating conditions. Results from startup and isothermal operation tests are presented. These results are also compared to theoretical performance predictions that were used to design the heat pipe initially.

Girrens, S.P.; Ernst, D.M.

1982-01-01T23:59:59.000Z

410

Heat pipe cooling for scramjet engines. Final report  

Science Conference Proceedings (OSTI)

Liquid metal heat pipe cooling systems have been investigated for the combustor liner and engine inlet leading edges of scramjet engines for a missile application. The combustor liner is cooled by a lithium-TZM molybdenum annular heat pipe, which incorporates a separate lithium reservoir. Heat is initially absorbed by the sensible thermal capacity of the heat pipe and liner, and subsequently by the vaporization and discharge of lithium to the atmosphere. The combustor liner temperature is maintained at 3400 F or less during steady-state cruise. The engine inlet leading edge is fabricated as a sodium-superalloy heat pipe. Cooling is accomplished by radiation of heat from the aft surface of the leading edge to the atmosphere. The leading edge temperature is limited to 1700 F or less. It is concluded that heat pipe cooling is a viable method for limiting scramjet combustor liner and engine inlet temperatures to levels at which structural integrity is greatly enhanced.

Silverstein, C.C.

1986-12-01T23:59:59.000Z

411

Glass-heat-pipe evacuated-tube solar collector  

DOE Patents (OSTI)

A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.

McConnell, R.D.; VanSant, J.H.

1981-08-06T23:59:59.000Z

412

Review of the Savannah River Site, Salt Waste Processing Facility, Construction Quality of Piping and Pipe Supports, September 2012  

NLE Websites -- All DOE Office Websites (Extended Search)

Savannah River Site, Salt Waste Processing Savannah River Site, Salt Waste Processing Facility, Construction Quality of Piping & Pipe Supports September 2012 Office of Safety and Emergency Management Evaluations Office of Enforcement and Oversight Office of Health, Safety and Security U.S. Department of Energy Table of Contents 1.0 Purpose................................................................................................................................................. 1 2.0 Scope.................................................................................................................................................... 1 3.0 Background .......................................................................................................................................... 1

413

Review of the Savannah River Site, Salt Waste Processing Facility, Construction Quality of Piping and Pipe Supports, September 2012  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savannah River Site, Salt Waste Processing Savannah River Site, Salt Waste Processing Facility, Construction Quality of Piping & Pipe Supports September 2012 Office of Safety and Emergency Management Evaluations Office of Enforcement and Oversight Office of Health, Safety and Security U.S. Department of Energy Table of Contents 1.0 Purpose................................................................................................................................................. 1 2.0 Scope.................................................................................................................................................... 1 3.0 Background .......................................................................................................................................... 1

414

High potential recovery -- Gas repressurization  

SciTech Connect

The objective of this project was to demonstrate that small independent oil producers can use existing gas injection technologies, scaled to their operations, to repressurize petroleum reservoirs and increase their economic oil production. This report gives background information for gas repressurization technologies, the results of workshops held to inform small independent producers about gas repressurization, and the results of four gas repressurization field demonstration projects. Much of the material in this report is based on annual reports (BDM-Oklahoma 1995, BDM-Oklahoma 1996, BDM-Oklahoma 1997), a report describing the results of the workshops (Olsen 1995), and the four final reports for the field demonstration projects which are reproduced in the Appendix. This project was designed to demonstrate that repressurization of reservoirs with gas (natural gas, enriched gas, nitrogen, flue gas, or air) can be used by small independent operators in selected reservoirs to increase production and/or decrease premature abandonment of the resource. The project excluded carbon dioxide because of other DOE-sponsored projects that address carbon dioxide processes directly. Two of the demonstration projects, one using flue gas and the other involving natural gas from a deeper coal zone, were both technical and economic successes. The two major lessons learned from the projects are the importance of (1) adequate infrastructure (piping, wells, compressors, etc.) and (2) adequate planning including testing compatibility between injected gases and fluids, and reservoir gases, fluids, and rocks.

Madden, M.P.

1998-05-01T23:59:59.000Z

415

Unusual plant features gas turbines  

SciTech Connect

Gas turbines were chosen by Phillips Petroleum Co. to operate the first gas-injection plant in the world to use gas-type turbines to drive reciprocating compressors. The plant is located in Lake Maracaibo, Venezuela. Gas turbines were chosen because of their inherent reliability as prime movers and for their lack of vibration. Reciprocating compressors were decided upon because of their great flexibility. Now, for the first time, the advantages of both gas turbines and reciprocating compressors are coupled on a very large scale. In this installation, the turbines will operate at about 5,000 rpm, while the compressors will run at only 270 rpm. Speed will be reduced through the giant gear boxes. The compressor platform rests on seventy- eight 36-in. piles in 100 ft of water. Piles were driven 180 ft below water level. To dehydrate the gas, Phillips will install a triethylene glycol unit. Two nearby flow stations will gather associated gas produced at the field and will pipe the gas underwater to the gas injection platform. Lamar Field is in the S. central area of Lake Maracaibo. To date, it has produced a 150 million bbl in 10 yr. Studies have indicated that a combination of waterflooding and repressuring by gas injection could double final recovery. Waterflooding began in 1963.

Franco, A.

1967-08-01T23:59:59.000Z

416

Characterization of an enriched uranyl fluoride deposit in a valve and pipe intersection using time-of-flight transmission measurements with {sup 252}Cf  

Science Conference Proceedings (OSTI)

A method was developed and successfully applied to characterize large uranyl fluoride (UO{sub 2}F{sub 2}) deposits at the former Oak Ridge Gaseous Diffusion Plant. These deposits were formed by a wet air in-leakage into the UF{sub 6} process gas lines over a period of years. The resulting UO{sub 2}F{sub 2} is hygroscopic, readily absorbing moisture from the air to form hydrates as UO{sub 2}F{sub 2}-nH{sub 2}O. The ratio of hydrogen to uranium can vary from 0--16, and has significant nuclear criticality safety impacts for large deposits. In order to properly formulate the required course of action, a non-intrusive characterization of the distribution of the fissile material within the pipe, its total mass, and amount of hydration was necessary. The Nuclear Weapons Identification System (NWIS) previously developed at the Oak Ridge Y-12 Plant for identification of uranium weapons components in storage containers was used to successfully characterize these deposits.

Wyatt, M.S. [Univ. of Tennessee, Knoxville, TN (United States). Dept. of Nuclear Engineering; Uckan, T.; Mihalczo, J.T.; Valentine, T.E. [Oak Ridge National Lab., TN (United States); Hannon, T.F. [East Tennessee Technology Park, Oak Ridge, TN (United States)

1998-06-01T23:59:59.000Z

417

Design and technology of heat pipes for cooling and heat exchange  

SciTech Connect

This new book presents a comprehensive account of heat pipe design, technology, and operation. It is based on insights and techniques developed by the author during more than twenty years of investigating high-performance heat pipe systems. The book provides information on a unique device with the capability to transport heat isothermally at high rates with no external power input. Emphasis is on high-performance liquid metal heat pipes, although nonliquid metal heat pipes are treated, as well. The first three chapters deal with the nonmathematical background for understanding heat pipe operation and heat transport capability. Remaining chapters detail heat pipe characteristics and design methods. Of special interest are simplified equations for obtaining heat pipe heat transport limits, heat pipe heat exchangers, heat pipe transient behavior, and inverted (nonwetting) heat pipes. Operational boundaries on heat pipe temperature and heat transport rate are described, and step-by-step procedures are given for involved calculations.

Silverstein, C.C.

1992-01-01T23:59:59.000Z

418

Beam-line cryopump  

DOE Green Energy (OSTI)

A cryopumping module using metallic surfaces at liquid helium temperature for condensation of hydrogen and deuterium gas has been constructed. This pump, a prototype of four units which will provide pumping for the Livermore 200 kV test stand, will be used to verify the concept and establish engineering parameters. Upon completion of engineering tests and evaluation the pump will be installed in an operating beam line. The design point pumping capacity is 80,000 liters per second for hydrogen and deuterium at 10$sup -4$ torr based on sticking coefficients of 0.15 and 0.25, respectively. Both the liquid helium temperature pumping surface and the liquid nitrogen temperature radiation shields are constructed of quilted double wall cylindrical shells. The pumping shell dimensions are 1.5 meters dia. x 0.6 meters long. Cryogen circulation is convection current driven in both cases. Liquid helium is supplied from an overhead Dewar through bayonet coupling. In the 200 kV beam line, pumping modules will be supplied via transfer lines from a central Dewar. Voltage standoff will be accomplished in the transfer lines. (auth)

Duffy, T.J.; Oddon, L.D.

1975-11-12T23:59:59.000Z

419

BEAM LINE  

NLE Websites -- All DOE Office Websites (Extended Search)

BEAM LINE BEAM LINE 45 W ILHELM ROENTGEN'S INITIAL DISCOVERY of X-radiation in 1895 led immediately to practical applications in medicine. Over the next few decades X rays proved to be an invaluable tool for the investigation of the micro-world of the atom and the development of the quantum theory of matter. Almost a century later, telescopes designed to detect X-radiation are indispensable for understanding the structure and evolution of the macro-world of stars, galaxies, and the Universe as a whole. The X-Ray Universe by WALLACE H. TUCKER X-ray images of the Universe are strikingly different from the usual visible-light images. 46 SUMMER 1995 did not think: I investigated." Undeterred by NASA's rejection of a proposal to search for cosmic X-radiation, Giacconi persuaded the

420

Corrosion cracking of gas-carrying pipelines  

Science Conference Proceedings (OSTI)

Samples of soil and other materials adhering to the outer and inner surfaces of pipeline coatings, and pieces of rupture pipe were studied to investigate causes of gas-carrying pipeline failures in Pakistan. Chemical analysis of the ruptured pipe shows the pipeline steel had no material flaw. X-ray diffraction studies of the soil reveal that it contains clay and nonclay minerals normally found. The material adhering to the coating facing the pipeline surface contains carbonates and bicarbonates of sodium, namely, nahcolite and trona. This study shows that nahcolite and trona, as products of cathodic protection that were then synthesized in the vicinity of the pipeline surface, could have attacked the pipe surface over the years and caused corrosion.

Hussain, K.; Shaukat, A.; Hassan, F.

1989-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Algeria: Ten Years of Independence  

E-Print Network (OSTI)

coastline of Algeria as refineries, pipe- lines and portsa large ethelene plant. Refineries which liquify gas and oil

Gallagher, Nancy

1972-01-01T23:59:59.000Z

422

SLURRY PIPE FLOW MEASUREMENTS USING TOMOGRAPHIC ULTRASONIC ...  

material in the pipeline may not be homogeneous, it will be difficult to obtain a representative sample for off-line measurements.

423

Persistence of a pinch in a pipe  

E-Print Network (OSTI)

The response of low-dimensional solid objects combines geometry and physics in unusual ways, exemplified in structures of great utility such as a thin-walled tube that is ubiquitous in nature and technology. Here we provide a particularly surprising consequence of this confluence of geometry and physics in tubular structures: the anomalously large persistence of a localized pinch in an elastic pipe whose effect decays very slowly as an oscillatory exponential with a persistence length that diverges as the thickness of the tube vanishes, which we confirm experimentally. The result is more a consequence of geometry than material properties, and is thus equally applicable to carbon nanotubes as it is to oil pipelines.

L. Mahadevan; A. Vaziri; Moumita Das

2006-07-13T23:59:59.000Z

424

Challenges with jointed-pipe underbalanced operations  

Science Conference Proceedings (OSTI)

Successful underbalanced operations demand a systematic approach with integration of engineering, operations, production, reservoir, and geology. There are significant advantages to underbalanced drilling (UD). Formation damage can be minimized if proper circulating fluids and operating parameters are chosen; there is an opportunity for reservoir evaluation and characterization while drilling; lost circulation and differential sticking can be avoided, combined with improvements in drilling rate of penetration (ROP); and it also provides an alternative method of well control. This paper discusses engineering challenges and considerations for underbalanced operations using multiphase flow as well as advances made during UD with rotary jointed pipe. Excluding air, mist, and foam, underbalanced techniques with multiphase fluids are reviewed. Much of the discussion and concepts also apply to coiled-tubing underbalanced operations.

Saponja, J.

1998-06-01T23:59:59.000Z

425

Transient performance investigation of a space power system heat pipe  

SciTech Connect

Start-up, shut-down, and peak power tests have been conducted with a molybdenum-lithium heat pipe at temperatures to 1500 K. The heat pipe was radiation coupled to a water cooled calorimeter for the tests with rf induction heating used for the input to the evaporator region. Maximum power throughput in the tests was 36.8 kw corresponding to a power density of 23 kw/cm/sup 2/ for the 1.4 cm diameter vapor space of the annular wick heat pipe. The corresponding evaporator flux density was approximately 150 w/cm/sup 2/ over an evaporator length of 40 cm at peak power. Condenser length for the tests was approximately 3.0 m. A variable geometry radiation shield was used to vary the load on the heat pipe during the tests. Results of the tests showed that liquid depletion in the evaporator region of the heat pipe could occur in shut-down and prevent restart of the heat pipe. Changes in surface emissivity of the heat pipe condenser surface were shown to affect the shut-down and re-start limits. 12 figs.

Merrigan, M.A.; Keddy, E.S.; Sena, J.T.

1986-01-01T23:59:59.000Z

426

Development and Manufacture of Cost Effective Composite Drill Pipe  

SciTech Connect

This technical report presents the engineering research, process development and data accomplishments that have transpired to date in support of the development of Cost Effective Composite Drill Pipe (CDP). The report presents progress made from October 1, 2004 through September 30, 2005 and contains the following discussions: (1) Qualification Testing; (2) Prototype Development and Testing of ''Smart Design'' Configuration; (3) Field Test Demonstration; and (4) Commercial order for SR-CDP from Torch International. The objective of this contract is to develop and demonstrate ''cost effective'' Composite Drill Pipe. It is projected that this drill pipe will weigh less than half of its steel counter part. The resultant weight reduction will provide enabling technology that will increase the lateral distance that can be reached from an offshore drilling platform and the depth of water in which drilling and production operations can be carried out. Further, composite drill pipe has the capability to carry real time signal and power transmission within the pipe walls. CDP can also accommodate much shorter drilling radius than is possible with metal drill pipe. As secondary benefits, the lighter weight drill pipe can increase the storage capability of floating off shore drilling platforms and provide substantial operational cost savings.

James C. Leslie; James C. Leslie II; Lee Truong; James T. Heard; Steve Loya

2006-02-20T23:59:59.000Z

427

The Economics of Steam Vs. Electric Pipe Heating  

E-Print Network (OSTI)

To properly design a pipe heating system, the basic principles of heat transfer from an insulated pipe must be understood. The three methods of heat flow are conduction, convection (both forced and natural) and radiation. The total heat loss from a pipe must be determined first, since this is the heat which must be replaced to maintain a pipe at a given temperature. A steam heating system requires an analysis of the heat loss from the pipe as well as an analysis of the capacity of the heating system. The economics of steam heat include the accessories as well as the inefficiencies of steam heat. The design of an electric heating system normally involves far fewer components and engineering complexities than does a comparable steam system. The basic system is comprised of the heater, controls and connection accessories. Today there are several economic trade-offs to be made in selecting a pipe heating system. These involve engineering and design costs, maintenance costs, installation costs and energy costs. The economic trade-offs to be made in selecting a pipe heating system do not universally favor one system over another for all cases.

Schilling, R. E.

1985-05-01T23:59:59.000Z

428

Development of the utilization of combustible gas produced in existing sanitary landfills: effects of corrosion at the Mountain View, CA Landfill Gas-Recovery Plant  

DOE Green Energy (OSTI)

Corrosion of equipment has occurred at the Mountain View, California Landfill Gas Recovery Plant. Corrosion is most severe on compressor valve seats and cages, tubes in the first and second stages of the interstage gas cooler, and first and second stage piping and liquid separators. Corrosion occurs because the raw landfill gas contains water, carbon dioxide, and oxygen. Some corrosion may also result from trace concentrations of organic acids present in the landfill gas. Corrosion of the third stage compressor, cooler, and piping does not occur because the gas is dehydrated immediately prior to the third stage. Controlling corrosion is necessary to maintain the mechanical integrity of the plant and to keep the cost of the gas competitive with natural gas. Attempts to reduce corrosion rates by injecting a chemical inhibitor have proved only partially successful. Recommendations for dealing with corrosion include earlier dehydration of the gas, selection of special alloys in critical locations, chemical inhibition, and regular plant inspections.

Not Available

1982-10-01T23:59:59.000Z

429

Capacitance Probe for Detection of Anomalies in Nonmetallic Plastic Pipe  

NLE Websites -- All DOE Office Websites (Extended Search)

Capacitance Probe for Detection of Anomalies in Capacitance Probe for Detection of Anomalies in Nonmetallic Plastic Pipe Opportunity The Department of Energy's National Energy Technology Laboratory (NETL) is seeking collaborative research and licensing partners interested in implementing United States Patent Number 7,839,282 entitled "Capacitance Probe for Detection of Anomalies in Nonmetallic Plastic Pipe." Disclosed in this patent is an analysis of materials using a capacitive sensor to detect anomalies in nonmetallic plastic pipe through comparison of measured capacitances. The capacitive sensor is used in conjunction with a capacitance measurement device, a location device, and a processor to generate a capacitance versus location output for the detection and localization of anomalies

430

Vibration test plan for a space station heat pipe subassembly  

SciTech Connect

This test plan describes the Sundstrand portion of task two of Los Alamos National Laboratory (LANL) contract 9-x6H-8102L-1. Sundstrand Energy Systems was awarded a contract to investigate the performance capabilities of a potassium liquid metal heat pipe as applied to the Organic Rankine Cycle (ORC) solar dynamic power system for the Space Station. The test objective is to expose the heat pipe subassembly to the random vibration environment which simulates the space shuttle launch condition. The results of the test will then be used to modify as required future designs of the heat pipe.

Parekh, M.B. [Sundstrand Energy Systems, Rockford, IL (United States)

1987-09-29T23:59:59.000Z

431

Pantex erects nearly 400 piping metal supports | National Nuclear Security  

NLE Websites -- All DOE Office Websites (Extended Search)

erects nearly 400 piping metal supports | National Nuclear Security erects nearly 400 piping metal supports | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Pantex erects nearly 400 piping metal supports Pantex erects nearly 400 piping metal supports Posted By Office of Public Affairs Workers at the Pantex Plant are in the process of erecting nearly 400 metal

432

Pantex erects nearly 400 piping metal supports | National Nuclear Security  

National Nuclear Security Administration (NNSA)

erects nearly 400 piping metal supports | National Nuclear Security erects nearly 400 piping metal supports | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Pantex erects nearly 400 piping metal supports Pantex erects nearly 400 piping metal supports Posted By Office of Public Affairs Workers at the Pantex Plant are in the process of erecting nearly 400 metal

433

Sizing Relationships for Pipe Wall Preheater-710 Reactor Experiment  

SciTech Connect

Relationships presented as curves are given that permit selection of preheater pipe diameters and lengths consistent with objective pressure drops, wall temperatures, and heat addition. The data are for 710 reactor experiment coolant and operating conditions.

Moon, C.W.

1965-01-29T23:59:59.000Z

434

High temperature heat pipes for waste heat recovery  

SciTech Connect

Operation of heat pipes in air at temperatures above 1200/sup 0/K has been accomplished using SiC as a shell material and a chemical vapor deposit (CVD) tungsten inner liner for protection of the ceramic from the sodium working fluid. The CVD tungsten has been used as a distribution wick for the gravity assisted heat pipe through the development of a columnar tungsten surface structure, achieved by control of the metal vapor deposition rate. Wick performance has been demonstrated in tests at approximately 2 kW throughput with a 19-mm-i.d. SiC heat pipe. Operation of ceramic heat pipes in repeated start cycle tests has demonstrated their ability to withstand temperature rise rates of greater than 1.2 K/s.

Merrigan, M.A.; Keddy, E.S.

1980-01-01T23:59:59.000Z

435

Information and self-selection in the PIPE market  

E-Print Network (OSTI)

PIPEs (Private Investments in Public Equity) are unique in that they are negotiated privately between sophisticated investors and the public firm. As a result, the issue price deviates from the firm's stock price, often ...

Koshal, Amit

2007-01-01T23:59:59.000Z

436

Evaluation of Stress Corrosion Cracking Susceptibility of Drill Pipe ...  

Science Conference Proceedings (OSTI)

G-105 and S-135 grades of drill pipe steels have been used to study the effect of temperature and solution chemistry on the stress corrosion cracking behavior of ...

437

Selection of minimum earthquake intensity in calculating pipe failure probabilities  

SciTech Connect

In a piping reliability analysis, it is sometimes necessary to specify a minimum ground motion intensity, usually the peak acceleration, below which the ground motions are not considered as earthquakes and, hence, are neglected. The calculated probability of failure of a piping system is dependent on this selected minimum earthquake intensity chosen for the analysis. A study was conducted to determine the effects of the minimum earthquake intensity on the probability of pipe failure. The results indicated that the probability of failure of the piping system is not very sensitive to the variations of the selected minimum peak ground acceleration. However, it does have significant effects on various scenarios that make up the system failure.

Lo, T.Y.

1985-01-01T23:59:59.000Z

438

Evaluation of Pipe-Type Cable Joint Restraint Systems  

Science Conference Proceedings (OSTI)

Joints in underground transmission pipe-type cables must be designed to accommodate the thermomechanical forces created as a cable heats and cools in operation. This report details an investigation of several joint restraining designs and recommends one design.

1990-04-06T23:59:59.000Z

439

Tornadogenesis with and without a Dynamic Pipe Effect  

Science Conference Proceedings (OSTI)

A dynamic pipe effect (DPE) has been used previously to explain the descent from aloft of tornadic vortex signatures (TVSs), and presumably embryonic tornadoes, prior to the near-ground spinup of the tornado. But for many tornadoes the TVS ...

R. Jeffrey Trapp; Robert Davies-Jones

1997-01-01T23:59:59.000Z

440

Have You Looked at Your Pipes Lately? | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Web sites. Addthis Related Articles Turn Down the Temp, But Don't Let Your Pipes Freeze Rooftop solar water heaters need regular maintenance to operate at peak efficiency. |...

Note: This page contains sample records for the topic "gas pipe line" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Steam bubble collapse, water hammer and piping network response  

E-Print Network (OSTI)

Work on steam bubble collapse, water hammer and piping network response was carried out in two closely related but distinct sections. Volume I of ,,is report details the experiments and analyses carried out in conjunction ...

Gruel, R.

442

Composite drill pipe and method for forming same  

DOE Patents (OSTI)

A lightweight and durable drill pipe string capable of short radius drilling formed using a composite pipe segment formed to include tapered wall thickness ends that are each defined by opposed frustoconical surfaces conformed for self-aligning receipt and intimate bonding contact within an annular space between corresponding surfaces of a coaxially nested set of metal end pieces and a set of nonconductive sleeves. The distal peripheries of the nested end pieces and sleeves are then welded to each other and the sandwiched and bonded portions are radially pinned. The composite segment may include imbedded conductive leads and the axial end portions of the end pieces are shaped to form a threaded joint with the next pipe assembly that includes contact rings in the opposed surfaces of the pipe joint for contact together.

Leslie, James C; Leslie, II, James C; Heard, James; Truong, Liem V; Josephson, Marvin

2012-10-16T23:59:59.000Z

443

NETL: News Release - Carbon Fiber Drill Pipe Demonstrates Resiliency...  

NLE Websites -- All DOE Office Websites (Extended Search)

lightweight drill pipe, made of space-age carbon fiber composites rather than traditional steel, is a step closer to becoming a major government-industry R&D success story. The...

444

Flow modification in McGill Heat Pipes.  

E-Print Network (OSTI)

??A heat pipe is a heat transfer device of very high thermal conductance that features two-phase flow. Research at McGill University has led to the… (more)

Lee, JuHee, 1973-

2005-01-01T23:59:59.000Z

445

Seismic Capacity of Threaded, Brazed, and Grooved Pipe Joints  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

SEISMIC CAPACITY OF THREADED, BRAZED AND GROOVED PIPE JOINTS Brent Gutierrez, PhD, PE George Antaki, PE, F.ASME DOE NPH Conference October 25-26, 2011 Motivation * Understand the...

446

Solid0Core Heat-Pipe Nuclear Batterly Type Reactor  

DOE Green Energy (OSTI)

This project was devoted to a preliminary assessment of the feasibility of designing an Encapsulated Nuclear Heat Source (ENHS) reactor to have a solid core from which heat is removed by liquid-metal heat pipes (HP).

Ehud Greenspan

2008-09-30T23:59:59.000Z

447

Membrane heat pipe development for space radiator applications  

SciTech Connect

A self-deploying membrane heat pipe (SMHP) is being designed and fabricated to operate in an in-cabin experiment aboard a STS flight. The heat pipe comprises a mylar membrane with a woven fabric arterial wick and R-11 as the working fluid. Preliminary results indicate that this SMHP design will successfully expand and retract in response to an applied heat load; the retraction force is provided by a constant force spring.

Woloshun, K.; Merrigan, M.

1986-01-01T23:59:59.000Z

448

Commercial high efficiency dehumidification systems using heat pipes  

SciTech Connect

An improved heat pipe design using separately connected two-section one-way flow heat pipes with internal microgrooves instead of wicks is described. This design is now commercially available for use to increase the dehumidification capacity of air conditioning systems. The design also includes a method of introducing fresh air into buildings while recovering heat and controlling the humidity of the incoming air. Included are applications and case studies, load calculations and technical data, and installation, operation, and maintenance information.

1993-09-01T23:59:59.000Z

449

Performance characteristics of gravity-assisted, potassium heat pipes  

SciTech Connect

Experiments with potassium-stainless steel gravity-assisted heat pipes were performed. Performance limitations due to entrainment or flooding of the liquid return flow are compared with analytical model predictions. The effect of heated pool height was investigated and problems with surface wetting are discussed. A comparison between entrainment limits for smooth-walled and textured-walled heat pipes was made and a minimum internal surface texturing depth is suggested.

Prenger, F.C.; Keddy, E.S.; Sena, J.T.

1985-01-01T23:59:59.000Z

450

Heat pipe thermal control of slender optics probes  

SciTech Connect

The thermal design for a stereographic viewing system is presented. The design incorporates an annular heat pipe and thermal isolation techniques. Test results are compared with design predictions for a prototype configuration. Test data obtained during heat pipe startup showing temperature gradients along the evaporator wall are presented. Correlations relating maximum wall temperature differences to a liquid Reynolds number were obtained at low power levels. These results are compared with Nusselt's Falling Film theory.

Prenger, F.C.

1979-01-01T23:59:59.000Z

451

DEVELOPMENT OF A PIPE CUT AND SEAL DIE  

SciTech Connect

A die was developed which will cut and seal the severed ends of 1 1/2 in. schedule 80, 347H stainless steel pipe. Some development work was done on dies for use on 1 1/2 in. outside diameter x 0.065 wall tube. Very limited work was done on dies for use on 2 1/2 in. schedule l60 pipe. (auth)

Wade, E.E.

1961-09-11T23:59:59.000Z

452

Heat pipe radiation cooling evaluation: Task 2 concept studies report  

SciTech Connect

This report presents the result of Task 2, Concept Studies for Heat Pipe Radiation Cooling (HPRC), which was performed for Los Alamos National Laboratory under Contract 9-XT1-U9567. Studies under a prior contract defined a reference HPRC conceptual design for hypersonic aircraft engines operating at Mach 5 and an altitude of 80,000 ft. Task 2 involves the further investigation of heat pipe radiation cooling (HPRC) systems for additional design and operating conditions.

Silverstein, C.C.

1991-10-01T23:59:59.000Z

453