1

HVAC component data modeling using industry foundation classes  

E-Print Network (OSTI)

HVAC Component Data Modeling Using Industry Foundationof a major extension of the HVAC part of the IFC data model.generic approach for handling HVAC components. This includes

Bazjanac, Vladimir; Forester, James; Haves, Philip; Sucic, Darko; Xu, Peng

2002-01-01T23:59:59.000Z

2

MODELING PARTICLE DEPOSITION ON HVAC HEAT EXCHANGERS  

E-Print Network (OSTI)

LBNL-49339 MODELING PARTICLE DEPOSITION ON HVAC HEAT EXCHANGERS J.A. Siegel1,3 * and W.W. Nazaroff2 Department of Energy under contract DE-AC03-76SF00098. #12;MODELING PARTICLE DEPOSITION ON HVAC HEAT, such as discontinuities in the fins, are hypothesized to be responsible for the discrepancy. INDEX TERMS HVAC, Fouling

3

Modeling and Simulation of HVAC Faulty Operations and Performance...  

NLE Websites -- All DOE Office Websites (Extended Search)

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues Title Modeling and Simulation of HVAC Faulty Operations and Performance...

4

Comparison of Building Energy Modeling Programs: HVAC Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Modeling Programs: HVAC Systems Title Comparison of Building Energy Modeling Programs: HVAC Systems Publication Type Report LBNL Report Number LBNL-6432E Year of Publication 2013...

5

Modeling and optimization of building HVAC systems.  

E-Print Network (OSTI)

??This thesis presents the development of hybrid modeling methodologies for HVAC component static/steady-state models and dynamic/transient models, and the development and implementation of a model-based… (more)

Jin, Guang Yu.

2012-01-01T23:59:59.000Z

6

Modeling and simulation of HVAC faults in EnergyPlus  

NLE Websites -- All DOE Office Websites (Extended Search)

simulation of HVAC faults in EnergyPlus Title Modeling and simulation of HVAC faults in EnergyPlus Publication Type Conference Paper Refereed Designation Refereed Year of...

7

BS-8: HVAC Modeling and Simulation  

NLE Websites -- All DOE Office Websites (Extended Search)

BS-8: HVAC Modeling and Simulation BS-8: HVAC Modeling and Simulation Speaker(s): Darko Sucic Date: December 5, 2001 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Satkartar K. Kinney Industry Foundation Classes (IFC), an object data model of buildings, are being developed by the International Alliance for Interoperability (IAI) to support data sharing and exchange in the building and construction industry. The IAI, founded in 1995, has published four releases of IFC so far. Several prototype implementations by leading software companies show that commercial IFC software is beginning to meet end user expectations of interoperability in the industry. BS-8 is an LBNL project that started last summer. It is developing the IFC HVAC extension schemata that will extend the IFC object data model and support the exchange of HVAC information

8

HVAC Modeling for Cost of Ownership Assessment in Biotechnology & Drugs Manufacturing  

E-Print Network (OSTI)

2000 Broomes, Peter. , “HVAC Modeling for Cost of Ownership2000 Broomes, Peter. , “HVAC Results Comparison”, April,HVAC Modeling for Cost of Ownership Assessment in

Broomes, Peter; Dornfeld, David A

2003-01-01T23:59:59.000Z

9

Model Predictive Control of HVAC Systems: Implementation and Testing at the University of California, Merced  

E-Print Network (OSTI)

Model Predictive Control of HVAC Systems:    Implementation and  air  conditioning  (HVAC)  account  for  27%  of  the reduction potential of HVAC systems with  active thermal 

Haves, Phillip

2010-01-01T23:59:59.000Z

10

Modeling and simulation of HVAC Results in EnergyPlus  

NLE Websites -- All DOE Office Websites (Extended Search)

Modeling and simulation of HVAC Results in EnergyPlus Title Modeling and simulation of HVAC Results in EnergyPlus Publication Type Journal Article LBNL Report Number LBNL-5564E...

11

Randomized Model Predictive Control for HVAC Systems  

Science Conference Proceedings (OSTI)

Heating, Ventilation and Air Conditioning (HVAC) systems play a fundamental role in maintaining acceptable thermal comfort and Indoor Air Quality (IAQ) levels, essentials for occupants well-being. Since performing this task implies high energy requirements, ... Keywords: Copulas, Learning, Randomized Model Predictive Control, Smart Buildings, Sustainable Control Systems

Alessandra Parisio, Damiano Varagnolo, Daniel Risberg, Giorgio Pattarello, Marco Molinari, Karl H. Johansson

2013-11-01T23:59:59.000Z

12

HVAC Room Temperature Prediction Control Based on Neural Network Model  

Science Conference Proceedings (OSTI)

HVAC (Heating Ventilating &Air-conditioning) system is a nonlinear complex system with delay. It is very difficult to build a mathematical model of HVAC and implement model-based control. Since a BP (Back Propagation) neural network can fully approximate ... Keywords: BP neural network, predictive control, HVAC, least squares method

Shujiang Li, Shuang Ren, Xiangdong Wang

2013-01-01T23:59:59.000Z

13

Modeling and Identification for HVAC Systems.  

E-Print Network (OSTI)

??Heating, Ventilation and Air Conditioning (HVAC) systems consist of all the equipment that control the conditions and distribution of indoor air. Indoor air must be… (more)

Scotton, Francesco

2012-01-01T23:59:59.000Z

14

Temporal model-based diagnostics generation for HVAC control systems  

Science Conference Proceedings (OSTI)

Optimizing energy usage in buildings requires global models that integrate multiple factors contributing to energy, such as lighting, "Heating, Ventilating, and Air Conditioning" (HVAC), security, etc. Model transformation methods can then use these ...

Marion Behrens; Gregory Provan

2010-06-01T23:59:59.000Z

15

Modeling particle deposition on HVAC heat exchangers  

E-Print Network (OSTI)

DEPOSITION ON HVAC HEAT EXCHANGERS JA Siegel 1,3 * and WWof fin-and-tube heat exchangers by particle deposition leadsparticle deposition on heat exchanger surfaces. We present a

Siegel, J.A.; Nazaroff, W.W.

2002-01-01T23:59:59.000Z

16

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Massieh Najafi1  

E-Print Network (OSTI)

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Massieh Najafi1 , David for determining HVAC diagnostics, methods to detect faults in HVAC systems are still generally undeveloped. Most in a substantial increase in energy use. For example, failure of an HVAC fan may prevent cool air from one

17

MODELING AND SIMULATION OF HVAC FAULTS IN ENERGYPLUS  

E-Print Network (OSTI)

Methodology for Secondary HVAC Systems, Doctoral Thesis,2002, Particulate Fouling of HVAC Heat Exchangers, Doctoraland diagnosis strategy for HVAC systems involving sensor

Basarkar, Mangesh

2013-01-01T23:59:59.000Z

18

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems  

E-Print Network (OSTI)

in Fault Diagnostics for HVAC Systems Massieh Najafi 1 ,tools for determining HVAC diagnostics, methods todetect faults in HVAC systems are still generally

Najafi, Massieh

2010-01-01T23:59:59.000Z

19

Building energy modeling programs comparison Research on HVAC systems  

NLE Websites -- All DOE Office Websites (Extended Search)

energy modeling programs comparison Research on HVAC systems energy modeling programs comparison Research on HVAC systems simulation part Title Building energy modeling programs comparison Research on HVAC systems simulation part Publication Type Journal Year of Publication 2013 Authors Zhou, Xin, Da Yan, Tianzhen Hong, and Dandan Zhu Keywords Building energy modeling programs, comparison tests, HVAC system simulation, theory analysis Abstract Building energy simulation programs are effective tools for the evaluation of building energy saving and optimization of design. The fact that large discrepancies exist in simulated results when different BEMPs are used to model the same building has caused wide concern. Urgent research is needed to identify the main elements that contribute towards the simulation results. This technical report summarizes methodologies, processes, and the main assumptions of three building energy modeling programs (BEMPs) for HVAC calculations: EnergyPlus, DeST, and DOE-2.1E, and test cases are designed to analyze the calculation process in detail. This will help users to get a better understanding of BEMPs and the research methodology of building simulation. This will also help build a foundation for building energy code development and energy labeling programs.

20

BLACK-BOX MODELLING OF HVAC SYSTEM: IMPROVING THE PERFORMANCES OF NEURAL NETWORKS  

E-Print Network (OSTI)

BLACK-BOX MODELLING OF HVAC SYSTEM: IMPROVING THE PERFORMANCES OF NEURAL NETWORKS Eric FOCK Ile de La Réunion - FRANCE ABSTRACT This paper deals with neural networks modelling of HVAC systems of HVAC system can be modelled using manufacturer design data presented as derived performance maps

Paris-Sud XI, Université de

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Tile of the document: HVAC system component-based modeling and implementation  

E-Print Network (OSTI)

1 Abstract Tile of the document: HVAC system component-based modeling and implementation Karam the foundation for modeling components that are used in HVAC systems (heating, ventilation, and air conditioning such functionalities. #12;2 HVAC system component-based modeling and implementation By Karam H. Rajab Scholarly

Austin, Mark

22

A new modelling methodology to control HVAC systems  

Science Conference Proceedings (OSTI)

Thermal comfort plays an important role in any working environment, but it is a very vague term and it is also very difficult to represent it on modern computers. Its proper definition could be a condition of the mind which expresses satisfaction with ... Keywords: Control, Energy, HVAC, Model, Thermal comfort

José A. Orosa

2011-04-01T23:59:59.000Z

23

A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS  

E-Print Network (OSTI)

1 A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS T. I describes a control scheme with fault detection capabilities suitable for application to HVAC systems as a reference of correct operation. Faults that occur in the HVAC system under control cause the PI

24

Analysis and modelling of membrane heat exchanger in HVAC energy recovery systems.  

E-Print Network (OSTI)

??The performance of membrane heat exchangers for HVAC total energy recovery systems was evaluated through experimentation and detailed system modelling. The operating principle of the… (more)

Nasif, Mohammad Shakir

2008-01-01T23:59:59.000Z

25

HVAC | OpenEI  

Open Energy Info (EERE)

HVAC HVAC Dataset Summary Description The following data-set is for a benchmark residential home for all TMY3 locations across all utilities in the US. The data is indexed by utility service provider which is described by its "unique" EIA ID ( Source National Renewable Energy Laboratory Date Released April 05th, 2012 (2 years ago) Date Updated April 06th, 2012 (2 years ago) Keywords AC apartment CFL coffeemaker Computer cooling cost demand Dishwasher Dryer Furnace gas HVAC Incandescent Laptop load Microwave model NREL Residential television tmy3 URDB Data text/csv icon Residential Cost Data for Common Household Items (csv, 14.5 MiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually Time Period License License Open Data Commons Public Domain Dedication and Licence (PDDL)

26

HVAC system modeling and optimization: a data-mining approach.  

E-Print Network (OSTI)

?? Heating, ventilating and air-conditioning (HVAC) system is complex non-linear system with multi-variables simultaneously contributing to the system process. It poses challenges for both system… (more)

Tang, Fan

2010-01-01T23:59:59.000Z

27

Application of computational intelligence in modeling and optimization of HVAC systems.  

E-Print Network (OSTI)

?? HVAC (Heating Ventilating and Air-Conditioning) system is multivariate, nonlinear, and shares time-varying characteristics. It poses challenges for both system modeling and performance optimization. Traditional… (more)

Li, Mingyang

2009-01-01T23:59:59.000Z

28

Co-simulation of innovative integrated HVAC systems in buildings  

E-Print Network (OSTI)

Integrated Simulation for HVAC Per- formance Prediction:air-conditioning equipment models (HVAC BESTEST), volume 1:air-conditioning equipment models (HVAC BESTEST), volume 2:

Trcka, Marija

2010-01-01T23:59:59.000Z

29

Demand Response-Enabled Model Predictive HVAC Load Control in Buildings using Real-Time Electricity Pricing.  

E-Print Network (OSTI)

??A practical cost and energy efficient model predictive control (MPC) strategy is proposed for HVAC load control under dynamic real-time electricity pricing. The MPC strategy… (more)

Avci, Mesut

2013-01-01T23:59:59.000Z

30

A Simple Path Loss Prediction Model for HVAC Systems O. K. Tonguz, D. D. Stancil, A. E. Xhafa, A. G. Cepni, P. V. Nikitin  

E-Print Network (OSTI)

1 A Simple Path Loss Prediction Model for HVAC Systems O. K. Tonguz, D. D. Stancil, A. E. Xhafa, A, and air conditioning (HVAC) cylindrical ducts in 2.4-2.5 GHz frequency band. The model we propose predicts the average power loss between a transmitter-receiver pair in an HVAC duct network. This prediction model

Stancil, Daniel D.

31

Identification of chiller model in HVAC system using fuzzy inference rules with Zadeh's implication operator  

Science Conference Proceedings (OSTI)

In the heating, ventilating, and air-conditioning (HVAC) system, chiller is the central part and one of the primary energy consumers. For the purpose of saving energy, the identification of the chiller model is of great significance. In this paper, based ... Keywords: chiller, fuzzy inference system, implication operator, improved genetic algorithm

Yukui Zhang; Shiji Song; Cheng Wu; Kang Li

2010-09-01T23:59:59.000Z

32

IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, VOL. 51, NO. 5, MAY 2003 945 Propagation Model for the HVAC Duct as a  

E-Print Network (OSTI)

for the HVAC Duct as a Communication Channel Pavel V. Nikitin, Member, IEEE, Daniel D. Stancil, Senior Member (HVAC) ducts in buildings are typically hollow metal pipes which can be used as waveguides to carry such a communication system. This paper presents a propagation model for a straight HVAC duct terminated at both ends

Stancil, Daniel D.

33

A multi-sensor based occupancy estimation model for supporting demand driven HVAC operations  

Science Conference Proceedings (OSTI)

Heating, ventilation, and air conditioning (HVAC) is a major energy consumer in buildings, and implementing demand driven HVAC operations is a way to reduce HVAC related energy consumption. This relies on the availability of occupancy information, which ... Keywords: HVAC, building energy consumption, demand driven, non-intrusive sensor, occupancy estimation

Zheng Yang; Nan Li; Burcin Becerik-Gerber; Michael Orosz

2012-03-01T23:59:59.000Z

34

A Qualitive Modeling Approach for Fault Detection and Diagnosis on HVAC Systems  

E-Print Network (OSTI)

This paper describes the basics and first test results of a model based approach using qualitative modeling to perform Fault Detection and Diagnostics (FDD) on HVAC and R systems. A quantized system describing the qualitative behavior of a dynamical system is established by transforming numerical inputs into qualitative values or states. Then, the qualitative model is used to determine system-states or outputs that may occur in the future. The qualitative model determines the probability that a subsequent condition might occur. The model can then be used for FDD purposes by comparing the expected states of the faultless system with the occurring states of the real process. The paper presents the first results of the model, trained with measurement data of an air handling unit (AHU) heating coil. The authors plan to extend the model to further AHU components and to test them against real data to assess their performance for FDD and their economic viability in terms of engineering efforts and costs by comparing them with a rule-based FDD system. It is then planned to implement and test the models on several large HVAC and R systems operating at two major European airports in the framework of the FP7 European project CASCADE ICT for Energy Efficient Airports.

Muller, T.; Rehault, N.; Rist, T.

2013-01-01T23:59:59.000Z

35

MODELING AND SIMULATION OF HVAC FAULTS IN ENERGYPLUS  

E-Print Network (OSTI)

sensor faults, Energy and Buildings. 42(4). April 2010.faults in buildings. Energy and Buildings. 42(1). Januaryon the DOE-2 model, Energy and Buildings. 21(2). 1994, Pages

Basarkar, Mangesh

2013-01-01T23:59:59.000Z

36

Particulate Fouling of HVAC Heat Exchangers Jeffrey Alexander Siegel  

E-Print Network (OSTI)

Particulate Fouling of HVAC Heat Exchangers by Jeffrey Alexander Siegel B.S. (Swarthmore College.......................................................................................xv CHAPTER 1: PARTICULATE FOULING OF HVAC HEAT EXCHANGERS ....1 1.1 Introduction.......................................................................11 CHAPTER 2: MODELING PARTICLE DEPOSITION ON HVAC HEAT EXCHANGERS

Siegel, Jeffrey

37

Dynamic modeling and global optimal operation of multizone variable air volume HVAC systems.  

E-Print Network (OSTI)

??Energy conservation and indoor environment concerns have motivated extensive research on various aspects of control of Heating, Ventilating and Air-Conditioning (HVAC) and building systems. The… (more)

Zheng, Guo Rong

1997-01-01T23:59:59.000Z

38

Influence Of Three Dynamic Predictive Clothing Insulation Models On Building Energy Use, HVAC Sizing And Thermal Comfort  

E-Print Network (OSTI)

ON BUILDING ENERGY USE, HVAC SIZING AND THERMAL COMFORT aThe results showed that when the HVAC is controlled based onequipment sizing. When the HVAC is controlled based on the

Schiavon, Stefano; Lee, Kwang Ho

2013-01-01T23:59:59.000Z

39

Renovating Residential HVAC Systems HVAC Systems  

E-Print Network (OSTI)

- 1 - LBNL 57406 Renovating Residential HVAC Systems HVAC Systems J.A. McWilliams and I.S. Walker and Air Conditioning), and Stacy Hunt and Ananda Harzell (IBACOS). #12;- 3 - Renovating Residential HVAC Guideline for Residential HVAC Retrofits (http

40

A model-based fault detection and diagnostic methodology for secondary HVAC systems.  

E-Print Network (OSTI)

??In the U.S., buildings consume 39 % of primary energy, of which, 13.5% is attributed to HVAC systems. Faults, arising from sensors, equipment, and control… (more)

Li, Shun

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

A model-based predictive supervisory controller for multi-evaporator HVAC systems  

Science Conference Proceedings (OSTI)

Multi-evaporator vapor compression cooling systems are representative of the complex, distributed nature of modern HVAC systems. Earlier research efforts focused on the development of a decentralized control architecture for individual evaporators that ...

Matthew S. Elliott; Bryan P. Rasmussen

2009-06-01T23:59:59.000Z

42

Model Code for the Control of Residential HVAC Distribution System Leakage and HVAC-Induced Building Leakage  

E-Print Network (OSTI)

Modifications to local and state codes are seen as an appropriate strategy for the prevention of residential air distribution system leakage and its impacts. A model code element has been developed to assist this strategy. Recent field studies of Florida residences by Cummings, Tooley and Moyer have revealed a mean leakage of 11 percent for the air distribution systems of central, fan-force heating and air conditioning systems. Such leakage may cause an estimated 20 percent increase in energy consumption for air conditioning, as well as a 50 percent increase in peak cooling load and an 80 percent increase in peak heating load. In addition, building air leakage may be expected to be several times greater when duct leakage is present or when avenues of air egress from closeable rooms are absent. The model duct construction element presented here contains all of the standards, definitions and code language needed to replace the current duct construction element of the local or state code. The content of this paper was used as a principal source for language adopted for the 1991 Florida Energy Efficiency Code For Building Construction. Addressed are the most appropriate standards required for the closure and sealing of metal duct, rigid fibrous glass duct, and nonmetallic flexible duct. Also addressed are (1) detailed requirements for the sealing of mechanical closets when they function as plenum chambers, (2) detailed requirements for the sealing of enclosed support platforms or air handlers and furnaces when they function as return duct, (3) detailed requirements for the sealing of uninhabitable cavities of the building structure, when they function as duct, and (4) detailed requirements for the egress of air from enclosed rooms which receive supply air. Where necessary, commentary is provided to explain the options available for implementing the model code provision as well as its ramifications. All provisions of this model code are compatible with the requirements, standards and guidelines contained in related documents published by the following organizations: the Southern Building Code Congress International, Inc., the Sheet Metal and Air Conditioning Contractors National Association, the American Society of Heating, Refrigerating and Air conditioning Engineers, Underwriters Laboratories, Inc., the Air Conditioning Contractors Of America, the Thermal Insulation Manufacturers Association, the National Fire Protection Association, and the Gypsum Association.

Wemhoff, P.

1990-01-01T23:59:59.000Z

43

Modeling Building Energy Use and HVAC Efficiency Improvements in Extreme Hot and Humid Regions  

E-Print Network (OSTI)

An energy analysis was performed on the Texas A & M University at Qatar building in Doha, Qatar. The building and its HVAC systems were modeled using EnergyPlus. Building chilled water and electrical data were collected to validate the computer simulation. The simulated monthly electricity consumption was within plus/minus 5 percent of the metered building data. Ninety-five percent of simulated hourly electricity data in a day were within plus/minus 10 percent of metered data. Monthly chilled water demand was within plus/minus 18 percent of measurements, and simulated monthly demand was correlated to metered monthly values with an R-squared correlation coefficient of 0.95. Once the simulation was verified with the metered data, an optimization of the building's HVAC systems was performed. Better utilizing the building's variable speed fans at part loads showed potential annual electricity savings of 16 percent over the base case, with another 22 percent savings in chilled water energy. After converting chilled water savings to equivalent chiller electricity savings, the potential utility cost savings over the base case were found to be $90,000/yr at local utility rates. Reducing outdoor air intake to ASHRAE indoor air quality minimums yielded an additional 17 percent in potential chilled water savings and brought total monetary savings over the base case to $110,000/yr. Using a dedicated outside air system to precisely control individual zone ventilation showed potential for an additional 12 percent chilled water savings and $14,000 in yearly utility savings, while also eliminating cases of under-ventilation. A hypothetical retrofit of fan powered terminal units (FPTU's) resulted in energy savings only at very low minimum flow rates, below ventilation standards. Savings were never more than 20 percent over the no-fan case. Series FPTU's showed no savings at any flow setting and negligible difference was found between ECM and SCR motor control. Finally, the dependence on climate of each improvement was studied. Simulations were run in the relatively milder climates of Houston and Phoenix and compared to those found for Doha. It was found that variable speed fan operation is a more cost effective option for milder climates, while outside air control is more cost effective in extreme hot and humid climates such as Doha. Future study is needed to make the FPTU model valid for different climates and flow ranges.

Bible, Mitchell

2011-08-01T23:59:59.000Z

44

Building Energy Software Tools Directory : HVAC Solution  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Solution Back to Tool Screenshot for HVAC Solution. Screenshot for HVAC Solution. Screenshot for HVAC Solution...

45

Empirical Methodologies for Improving HVAC Efficiency  

NLE Websites -- All DOE Office Websites (Extended Search)

Empirical Methodologies for Improving HVAC Efficiency Empirical Methodologies for Improving HVAC Efficiency Speaker(s): Anil Aswani Date: September 21, 2012 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Michael Wetter This talk describes the use of empirical methodologies that we have developed for the purpose of improving heating, ventilation, and air-conditioning (HVAC) efficiency through better control algorithms and configuration. We show that semiparametric regression can both identify simplified models of thermal HVAC dynamics while also estimating time-varying heating loads using only real-time temperature measurements from thermostats. These models can be used with our learning-based model predictive control (LBMPC) method in order to improve the energy-efficiency of HVAC. Experiments on testbeds with different types of HVAC show the

46

IFC HVAC interface to EnergyPlus - A case of expanded interoperability for energy simulation  

E-Print Network (OSTI)

D. Sucic and P. Xu. 2002. HVAC Component Data Modeling Using2001. BS-8 project: IFC HVAC extension schemata. http://IFC HVAC INTERFACE TO ENERGYPLUS – A CASE OF EXPANDED

Bazjanac, Vladimir; Maile, Tobias

2004-01-01T23:59:59.000Z

47

SIMULATION AND EXPERIMENTAL VALIDATION OF AIRBORNE AND STRUCTURE-BORNE NOISE TRANSMISSION IN HVAC PLENUMS.  

E-Print Network (OSTI)

??This research demonstrates the usage of numerical acoustics to model sound and vibrational energy propagation in HVAC ducts and plenums. Noise and vibration in HVAC… (more)

Ramalingam, Srinivasan

2012-01-01T23:59:59.000Z

48

Field comparison of conventional HVAC systems with a residential gas-engine-driven heat pump  

SciTech Connect

Through its Office of Federal Energy Management Program (FEMP), the US Department of Energy (DOE) provides technical and administrative support to federal agency programs directed at reducing energy consumption and cost in federal buildings and facilities. One such program is the New Technology Demonstration Program (NTDP). In this context, NTDP is a demonstration of a US energy-related technology at a federal site. Through a partnership with a federal site, the utility serving the site, a manufacturer of an energy-related technology, and other organizations associated with these interests, DOE can evaluate new technologies. The partnership of these interests is secured through a Cooperative Research and Development Agreement (CRADA). The Fort Sam Houston (San Antonio, Texas) NTDP is a field evaluation of a 3-ton gas-engine-driven residential heat pump. Details of the technical approach used in the evaluation, including instrumentation and methodology, are presented. Dynamic performance maps, based on field data, are developed for the existing residential furnaces and air conditioners at Fort Sam Houston. These maps are the basis for comparisons between the candidate and current equipment. The approach offers advantages over pre/post-measure evaluations by decoupling the measured equipment performance from the effects of different envelope characteristics, occupant behavior, and weather.

Miller, J.D.

1994-08-01T23:59:59.000Z

49

System dynamics based models for selecting HVAC systems for office buildings: a life cycle assessment from carbon emissions perspective.  

E-Print Network (OSTI)

??This study aims to explore the life cycle environmental impacts of typical heating ventilation and air condition (HVAC) systems including variable air volume (VAV) system,… (more)

Chen, S

2011-01-01T23:59:59.000Z

50

Occupancy Based Demand Response HVAC Control Strategy Varick L. Erickson  

E-Print Network (OSTI)

proposes an HVAC control strategy based on occupancy prediction and real time occupancy monitoring via simulation model. We dis- cuss the building parameters and the HVAC control strate- gies used for the energyOccupancy Based Demand Response HVAC Control Strategy Varick L. Erickson University of California

Cerpa, Alberto E.

51

HVAC Maintenance and Technologies  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC - HVAC - Maintenance and Technologies Federal Utility Partnership Working Group Meeting Providence, Rhode Island April 15, 2010 BY Ramin Faramarzi, P.E. Technology Test Centers (TTC) Design and Engineering Services Southern California Edison (SCE) www.sce.com/rttc 2 Outline * Introduction to SCE's TTC * Overview of energy challenges in California (CA) * Role of HVAC in CA's energy and demand equations * Factors affecting HVAC performance * Focus on SCE's research on maintenance faults * Next generation of HVAC equipment * HVAC technologies on SCE's TTC radar * Black boxes - do they all work? 3 SCE's Technology Test Centers * SCE applied research facilities located in Irwindale, CA comprised of 3 test beds: * Refrigeration * HVAC * Lighting * Coming Soon! - A new ZNE lab 4 Refrigeration Testing

52

HVAC Installed Performance  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Installed Performance HVAC Installed Performance ESI, Tim Hanes Context * The building envelope has historically been the focus in residential homes. * The largest consumer of energy in residential homes is typically the HVAC system. * Testing the performance of the HVAC system has not been pursued to its full potential. Technical Approach * Currently very little performance testing is being done to the HVAC system. * The only way to know if a HVAC system is operating correctly is to measure the Btu/h. * This should be done at the equipment and at the the system. Recommended Guidance * Training of HVAC technicians, installers, and salespeople is a must. * If only the technician is trained than implementing the change will not happen. * Public awareness of proper installation and its

53

Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1  

E-Print Network (OSTI)

Efficiency Choice 6.3 New Home HVAC System Choice 6.4. NewJuly. EPRI. 1990. REEPS 2.0 HVAC Model Logic, prepared by1990. Review of Equipment HVAC Choice Parameters. Cambridge

Johnson, F.X.

2010-01-01T23:59:59.000Z

54

The influence of HVAC systems on secondary organic aerosol formation Michael S. Waring1  

E-Print Network (OSTI)

The influence of HVAC systems on secondary organic aerosol formation Michael S. Waring1 , Jeffrey A, ventilation, and air- conditioning (HVAC) system. This study models the influence of HVAC systems on SOA. The most influential HVAC parameters are the flow rates, particle filtration, and indoor temperature

Siegel, Jeffrey

55

Multiple sensors with single HVAC system control  

E-Print Network (OSTI)

sensor; HVAC; control system; optimization; multi channeloptimization method is designed to be independent of the HVAC

Lin, Craig; Federspiel, Clifford; Auslander, David

2002-01-01T23:59:59.000Z

56

Pedernales Electric Cooperative - HVAC Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pedernales Electric Cooperative - HVAC Rebate Program Pedernales Electric Cooperative - HVAC Rebate Program Pedernales Electric Cooperative - HVAC Rebate Program < Back Eligibility Commercial Residential Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Program Info State Texas Program Type Utility Rebate Program Utility Rebate Program Rebate Amount Central AC with Gas Furnace: $300 - $400/unit Heat Pump: $400 - $500/unit Dual-Fuel Heat Pump: $400 - $500/unit Geothermal Heat Pump: $1,000/unit Water-Source Heat Pump: $1,000/unit Provider Pedernales Electric Cooperative Pedernales Electric Cooperative offers equipment rebates to members who install energy efficient HVAC equipment. Eligible equipment includes:

57

CALIFORNIA ENERGY Large HVAC Building  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Large HVAC Building Survey Information Database of Buildings over 100 Design of Large Commercial HVAC Systems research project, one of six research elements in the Integrated Design of Large Commercial HVAC Systems Integrated Design of Small Commercial HVAC Systems Integrated

58

BFRL: HVAC&R - Publications  

Science Conference Proceedings (OSTI)

HVAC&R Equipment Performance Group. Publications. Repeatability of Energy Consumption Test Results for Compact Refrigerators ...

59

HVAC Maintenance and Technologies | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Maintenance and Technologies HVAC Maintenance and Technologies Presentation covers the HVAC maintenance and technologies, and is given at the Spring 2010 Federal Utility...

60

Wireless Demand Response Controls for HVAC Systems  

E-Print Network (OSTI)

Response Controls for HVAC Systems Clifford Federspiel,tests. Figure 5: Specific HVAC electric power consumptioncontrol, demand response, HVAC, wireless Executive Summary

Federspiel, Clifford

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

MAPPING HVAC SYSTEMS FOR SIMULATION IN ENERGYPLUS  

E-Print Network (OSTI)

LBNL-XXXXX MAPPING HVAC SYSTEMS FOR SIMULATION IN ENERGYPLUSof California. MAPPING HVAC SYSTEMS FOR SIMULATION INpresent a conventional view of HVAC systems to the user, and

Basarkar, Mangesh

2013-01-01T23:59:59.000Z

62

Measuring Advances in HVAC Distribution System Design  

E-Print Network (OSTI)

Gabel and Andresen, HVAC Secondary Toolkil. Atlanta: ASHRAE,P_02 Measuring Advances in HVAC Distribution System Designdesign and operation of the HVAC thermal distribution system

Franconi, E.

2011-01-01T23:59:59.000Z

63

HVAC Installed Performance  

Energy.gov (U.S. Department of Energy (DOE))

This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question HVAC proper installation energy savings: over-promising or under-delivering?"

64

Model Predictive Control for Energy Efficient Buildings  

E-Print Network (OSTI)

P. Haves et al. “Model Predictive Control of HVAC Systems:Bilinear Model Predictive Control of a HVAC System Usingof model predictive control algorithms for HVAC systems.

Ma, Yudong

2012-01-01T23:59:59.000Z

65

Weather-clustering based strategy design for dynamic demand response building HVAC control  

Science Conference Proceedings (OSTI)

Energy consumption and room temperature can be simulated using EnergyPlus model, given the building model, weather information, and HVAC control strategy. For a given weather forecast, however, online simulation-based optimization of the HVAC control ... Keywords: EnergyPlus, building HVAC control strategy, clustering, dynamic demand response

Rui Liao; Geng Li; Shun Miao; Yan Lu; Jianmin Zhu; Ling Shen

2012-11-01T23:59:59.000Z

66

Simulation and Optimization of HVAC Systems  

E-Print Network (OSTI)

We developed a mathematical model of a simple Heating, Ventilation and Air Conditioning (HVAC) system and implemented the model using the VisSim simulation language. We used Fourier methods to approximate (and simplify) temperature and humidity data for the model. We created an objective function to be minimized which recorded the cost of running this HVAC system. We studied different methods for minimizing the cost function, including direct search methods using VisSim and completed preliminary studies of a Dynamic Programming programming approach to simplify the optimization problem. ii Contents 0 Executive Summary 1 1 Introduction 2 2 Evaluation of Simulation Packages 3 3 Simple Room Model for an HVAC System 5 3.1 Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3.2 Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3.3 Splitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3.4 Mixer . . . ....

Ane Coughlin; George D. Ellington; Ellen Phifer; Brian Rieksts

1998-01-01T23:59:59.000Z

67

International Energy Agency Building Energy Simulation Test and Diagnostic Method for Heating, Ventilating, and Air-Conditioning Equipment Models (HVAC BESTEST); Volume 1: Cases E100-E200  

DOE Green Energy (OSTI)

This report describes the Building Energy Simulation Test for Heating, Ventilating, and Air-Conditioning Equipment Models (HVAC BESTEST) project conducted by the Tool Evaluation and Improvement International Energy Agency (IEA) Experts Group. The group was composed of experts from the Solar Heating and Cooling (SHC) Programme, Task 22, Subtask A. The current test cases, E100-E200, represent the beginning of work on mechanical equipment test cases; additional cases that would expand the current test suite have been proposed for future development.

Neymark, J.; Judkoff, R.

2002-01-01T23:59:59.000Z

68

BFRL: HVAC&R - Publications  

Science Conference Proceedings (OSTI)

HVAC&R Equipment Performance Group. Publications. Fundamental Aspects of the Application of Carbon Dioxide in Comfort Cooling. ...

69

VENTILATION (HVAC) FAILURE (BUILDING WIDE)  

E-Print Network (OSTI)

VENTILATION (HVAC) FAILURE (BUILDING WIDE) A failure or shutdown of the ventilation system will be signaled by cessation of the audible background "rumbling" sound of the building's HVAC system. As building durations. NOTE: Due to unpredictable pressure differentials in and around the labs during an HVAC failure

Strynadka, Natalie

70

Luminaire/plenum/HVAC simulator  

SciTech Connect

This paper describes a new apparatus designed to model the physical parameters that affect fluorescent lamp performance under realistic operating conditions. These parameters include fixture type, mounting configuration, HVAC integration, and room air temperature, which directly determine the minimum lamp wall temperature (MLWT) and, therefore, the resulting light output of the lamp/ballast system. This apparatus is used principally to measure MLWT under operating conditions, which enables us to identify the effects the major parameters have on lamp/ballast system performance. Initial parametric results illustrate the use of this apparatus to provide representative MLWTs for a range of application conditions.

Siminovitch, M.J.; Rubinstein, F.M.; Clark, T.A.; Verderber, R.R.

1985-07-01T23:59:59.000Z

71

A Fault Detection and Diagnosis Method for HVAC Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

A Fault Detection and Diagnosis Method for HVAC Systems A Fault Detection and Diagnosis Method for HVAC Systems Speaker(s): Peng Xu Date: December 2, 2002 - 12:00pm Location: Bldg. 90 There is a growing consensus that most buildings do not perform as well as intended and that faults in HVAC systems are widespread in commercial buildings. An automated fault detection and diagnosis tool for HVAC systems is being developed, based on an integrated, life-cycle, approach to commissioning and performance monitoring. The tool uses component-level HVAC equipment models implemented in the SPARK equation-based simulation environment. The models are configured using design information and component manufacturers' data and then fine-tuned to match the actual performance of the equipment by using data measured during functional tests

72

Definition: HVAC | Open Energy Information  

Open Energy Info (EERE)

HVAC HVAC Jump to: navigation, search Dictionary.png HVAC An abbreviation for the heating, ventilation, and air-conditioning system; the system or systems that condition air in a building.[1] View on Wikipedia Wikipedia Definition HVAC is the technology of indoor and vehicular environmental comfort. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. Refrigeration is sometimes added to the field's abbreviation as HVAC&R or HVACR, or ventilating is dropped as in HACR (such as the designation of HACR-rated circuit breakers). HVAC is important in the design of medium to large industrial and office buildings such as skyscrapers and in marine environments such as aquariums, where safe and

73

Building Energy Software Tools Directory: HVAC 1 Toolkit  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC 1 Toolkit HVAC 1 Toolkit HVAC 1 Toolkit logo. The Toolkit for Primary HVAC System Energy Calculations is a collection of thirty-eight separate subroutines and corresponding documentation that describes algorithms for predicting the performance of HVAC components. The Toolkit documentation includes thorough descriptions of the component models and solution algorithms, detailed information on the structure of the individual FORTRAN 77 routines, as well as illustrative examples of system simulations with the Toolkit routines. The Toolkit serves two purposes: modules for large-scale simulation and stand-alone component performance prediction. The Toolkit components can also be used to calculate the energy performance of a component with a dedicated driver program to provide the necessary information flow to the Toolkit routines.

74

CALIFORNIA ENERGY Large HVAC Energy Impact Report  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Large HVAC Energy Impact Report Statewide Energy Impact Report are part of the Integrated Design of Large Commercial HVAC Systems research project. The reports: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

75

International Energy Agency Building Energy Simulation Test and Diagnostic Method for Heating, Ventilating, and Air-Conditioning Equipment Models (HVAC BESTEST): Volume 2: Cases E300-E545.  

DOE Green Energy (OSTI)

This report documents an additional set of mechanical system test cases that are planned for inclusion in ANSI/ASHRAE STANDARD 140. The cases test a program's modeling capabilities on the working-fluid side of the coil, but in an hourly dynamic context over an expanded range of performance conditions. These cases help to scale the significance of disagreements that are less obvious in the steady-state cases. The report is Vol. 2 of HVAC BESTEST Volume 1. Volume 1 was limited to steady-state test cases that could be solved with analytical solutions. Volume 2 includes hourly dynamic effects, and other cases that cannot be solved analytically. NREL conducted this work in collaboration with the Tool Evaluation and Improvement Experts Group under the International Energy Agency (IEA) Solar Heating and Cooling Programme Task 22.

Neymark J.; Judkoff, R.

2004-12-01T23:59:59.000Z

76

Fault Detection and Diagnosis in Building HVAC Systems  

E-Print Network (OSTI)

techniques for model-based FDD methods applied to vapordetection and diagnosis (FDD) has been an active area for6-17]. In building HVAC systems, FDD has received increasing

Najafi, Massieh

2010-01-01T23:59:59.000Z

77

HVAC Sensors, Controls, and Human Feedback Interfaces  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Sensors, HVAC Sensors, Controls, and Human Controls, and Human Feedback Interfaces Feedback Interfaces April 26, 2010 Dr. Amr Gado Emerson Climate Technologies Heating And...

78

Building Technologies Office: Transitioning Traditional HVAC...  

NLE Websites -- All DOE Office Websites (Extended Search)

Traditional HVAC Contractors to Whole House Performance Expert Meeting Building America hosted the "Transitioning Traditional HVAC Contractors to Whole House Performance...

79

Building Technologies Office: Transitioning Traditional HVAC...  

NLE Websites -- All DOE Office Websites (Extended Search)

Transitioning Traditional HVAC Contractors to Whole House Performance Expert Meeting to someone by E-mail Share Building Technologies Office: Transitioning Traditional HVAC...

80

Measuring Outdoor Airflow into HVAC Systems  

E-Print Network (OSTI)

MEASURING OUTDOOR AIRFLOW INTO HVAC SYSTEMS W i l l i a m J.minimum OA flow rate if HVAC system has an economizer

Fisk, William J.; Faulkner, David; Sullivan, Douglas P.

2005-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Building Energy Software Tools Directory: HVAC Solution  

NLE Websites -- All DOE Office Websites (Extended Search)

design and specify HVAC equipment. Pick familiar objects like boilers, pumps, fan coils and air handlers and using drag and drop methods, connect them to form a HVAC...

82

Development of an automated methodology for calibration of simplified air-side HVAC system models and estimation of potential savings from retrofit/commissioning measures  

E-Print Network (OSTI)

This dissertation provides one methodology to determine potential energy savings of buildings with limited information. This methodology is based upon the simplified energy analysis procedure of HVAC systems and the control of the comfort conditions. Numerically, the algorithm is a tailored exhaustive search over all the independent variables that are commonly controlled for a specific type of HVAC system. The potential energy savings methodology has been applied in several buildings that have been retrofitted and/or commissioned previously. Results from the determined savings for the Zachry building at Texas A&M after being commissioned show a close agreement to the calculated potential energy savings (about 85%). Differences are mainly attributed to the use of simplified models. Due to the restriction of limited information about the building characteristics and operational control, the potential energy savings method requires the determination of parameters that characterize its thermal performance. Thus, a calibrated building is needed. A general procedure has been developed to carry out automated calibration of building energy use simulations. The methodology has been tested successfully on building simulations based on the simplified energy analysis procedure. The automated calibration is the minimization of the RMSE of the energy use over daily conditions. The minimization procedure is fulfilled with a non-canonical optimization algorithm, the Simulated Annealing, which mimics the Statistical Thermodynamic performance of the annealing process. That is to say, starting at a specified temperature the algorithm searches variable-space states that are steadier, while heuristically, by the Boltzmann distribution, the local minima is avoided. The process is repeated at a new lower temperature that is determined by a specific schedule until the global minimum is found. This methodology was applied to the most common air-handler units producing excellent results for ideal cases or for samples modified with a 1% white noise.

Baltazar Cervantes, Juan Carlos

2006-12-01T23:59:59.000Z

83

HVAC Improvements for Existing Houses  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Improvements for Existing Houses HVAC Improvements for Existing Houses Speaker(s): Chryséis Bovagnet Date: September 5, 2002 - 12:00pm Location: Bldg. 90 Many older houses in the US are either not well designed from a thermal point of view or have HVAC (Heating Ventilation and Air Conditioning) systems in need of repairs or improvements. The building envelopes tend to have poor insulation and lots of leakage, and the HVAC systems are inefficient. The cooling/heating equipment is often located outside of the conditioned space (e.g. in attics or crawlspaces) with ducts that leak and have poor insulation, which cause energy loss and bad occupant comfort on peak days or in extreme climates. We developed a series of retrofits that will allow us to reduce the energy consumption of residential HVAC

84

Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1  

E-Print Network (OSTI)

LBL-34045 UC-1600 Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting-uses include Heating, Ventilation and Air Conditioning (HVAC). Our analysis uses the modeling framework provided by the HVAC module in the Residential End-Use Energy Planning System (REEPS), which was developed

85

REDESIGN OF HVAC SYSTEM TO IMPROVE ENERGY EFFICIENCY OF EDUCATIONAL BUILDING.  

E-Print Network (OSTI)

??An energy modeling software was used to analyze the current building configuration and simulations were performed in an attempt to redesign the current HVAC system… (more)

Hagene, Brian Matthew

2012-01-01T23:59:59.000Z

86

Strategy Guideline: HVAC Equipment Sizing  

SciTech Connect

The heating, ventilation, and air conditioning (HVAC) system is arguably the most complex system installed in a house and is a substantial component of the total house energy use. A right-sized HVAC system will provide the desired occupant comfort and will run efficiently. This Strategy Guideline discusses the information needed to initially select the equipment for a properly designed HVAC system. Right-sizing of an HVAC system involves the selection of equipment and the design of the air distribution system to meet the accurate predicted heating and cooling loads of the house. Right-sizing the HVAC system begins with an accurate understanding of the heating and cooling loads on a space; however, a full HVAC design involves more than just the load estimate calculation - the load calculation is the first step of the iterative HVAC design procedure. This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

Burdick, A.

2012-02-01T23:59:59.000Z

87

The Optimization of Control Parameters for VAV HVAC System Commissioning  

E-Print Network (OSTI)

One of the technical subjects in commissioning for HVAC system is to enhance control performance and time efficiency, while the tuning of the optimal parameters to control HVAC system takes much time and labor in particular. Therefore, we propose a kind of commissioning technique as follows. We identified the dynamic characteristics of components of an actual VAV HVAC system such as rooms, VAV dampers, two way valves and chilled water coils, and verified the behaviors of the models and choose the optimal control parameters on a personal computer. Then adopting them for the actual system, we verified the control performance. Through the procedure, we showed the possibility of off-site and off-line control parameter tuning to reduce the cost and time at on-site and in on-line using the measured data in a real HVAC system.

Song, S.; Maehara, K.; Sagara, N.

2006-01-01T23:59:59.000Z

88

Porous insulation in HVAC systems  

Science Conference Proceedings (OSTI)

Porous insulation used to line the air stream surfaces of HVAC equipment provides a locus for the accumulation of dirt and debris. Dirt and debris are hydrophilic and the insulation on the air stream surfaces of mechanical cooling systems thus provides a niche for mold growth. The mold growing on porous insulation unlike moldy debris on a hard surface such as sheetmetal cannot be removed by duct cleaning. Actions for proactively preventing biocontamination of HVAC insulation include the following. (1) Porous insulation shall not be used to line the air stream surfaces of HVAC plenums where wetting is likely such as in the vicinity of cooling coils

Philip R. Morey

1995-01-01T23:59:59.000Z

89

Classroom HVAC: Improving ventilation and saving energy -- field study plan  

E-Print Network (OSTI)

in this study. Classroom HVAC: Improving Ventilation andV8doc.sas.com/sashtml. Classroom HVAC: Improving VentilationBerkeley, CA 94720. Classroom HVAC: Improving Ventilation

Apte, Michael G.; Faulkner, David; Hodgson, Alfred T.; Sullivan, Douglas P.

2004-01-01T23:59:59.000Z

90

Inverted Attic Bulkhead for HVAC Ductwork | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Inverted Attic Bulkhead for HVAC Ductwork Inverted Attic Bulkhead for HVAC Ductwork Inverted Attic Bulkhead for HVAC Ductwork, Roseville, California (Fact Sheet), Building America...

91

Fault Detection and Diagnosis in Building HVAC Systems  

E-Print Network (OSTI)

Wright, “Condition monitoring in HVAC subsystems using firstmonitoring packaged HVAC equipment. ASHRAE Transactions”,Detection and Diagnosis of HVAC Systems Using Support Vector

Najafi, Massieh

2010-01-01T23:59:59.000Z

92

Energy-Efficient Building HVAC Control Using Hybrid System LBMPC  

E-Print Network (OSTI)

Improving the energy-efficiency of heating, ventilation, and air-conditioning (HVAC) systems has the potential to realize large economic and societal benefits. This paper concerns the system identification of a hybrid system model of a building-wide HVAC system and its subsequent control using a hybrid system formulation of learning-based model predictive control (LBMPC). Here, the learning refers to model updates to the hybrid system model that incorporate the heating effects due to occupancy, solar effects, outside air temperature (OAT), and equipment, in addition to integrator dynamics inherently present in low-level control. Though we make significant modeling simplifications, our corresponding controller that uses this model is able to experimentally achieve a large reduction in energy usage without any degradations in occupant comfort. It is in this way that we justify the modeling simplifications that we have made. We conclude by presenting results from experiments on our building HVAC testbed, which s...

Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

2012-01-01T23:59:59.000Z

93

Influence Of Three Dynamic Predictive Clothing Insulation Models On Building Energy Use, HVAC Sizing And Thermal Comfort  

E-Print Network (OSTI)

uc/item/3sx6n876 gas fired boiler, variable speed pumps andL/s·m Values Chiller design COP Boiler design efficiency 3.4due to the lowest annual boiler energy. The annual heating

Schiavon, Stefano; Lee, Kwang Ho

2013-01-01T23:59:59.000Z

94

Influence Of Three Dynamic Predictive Clothing Insulation Models On Building Energy Use, HVAC Sizing And Thermal Comfort  

E-Print Network (OSTI)

CLOTHING INSULATION MODELS ON BUILDING ENERGY USE, HVACClothing Insulation Model; Clothing; Building Energy;clothing insulation models on the building simulation is

Schiavon, Stefano; Lee, Kwang Ho

2013-01-01T23:59:59.000Z

95

Building Energy Software Tools Directory : HVAC Residential Load...  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Residential Load Calcs HD for the iPad Back to Tool HVAC Residential Load Calcs HD screenshot HVAC Residential Load Calcs HD screenshot HVAC Residential Load Calcs HD...

96

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Custom, HVAC, and Motor Business Efficiency Incentives Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives Eligibility Commercial Industrial...

97

Influence Of Three Dynamic Predictive Clothing Insulation Models On Building Energy Use, HVAC Sizing And Thermal Comfort  

E-Print Network (OSTI)

Predictive Clothing Insulation Models based on Outdoor AirPREDICTIVE CLOTHING INSULATION MODELS ON BUILDING ENERGYthat the clothing insulation is equal to a constant value of

Schiavon, Stefano; Lee, Kwang Ho

2013-01-01T23:59:59.000Z

98

Building HVAC Requirements Overview Page 4-1 4 Building HVAC Requirements  

E-Print Network (OSTI)

Building HVAC Requirements ­ Overview Page 4-1 4 Building HVAC Requirements 4.1 Overview 4 conditioning (HVAC) systems. The requirements are presented in this chapter so that it may serve as a single. 2008 Residential Compliance Manual August 2009 #12;Page 4-2 Building HVAC Requirements ­ Overview 4

99

Development Practice in HVAC Controls  

NLE Websites -- All DOE Office Websites (Extended Search)

Development Practice in HVAC Controls Development Practice in HVAC Controls Speaker(s): John Zhou Date: April 11, 2011 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Philip Haves The presentation will introduce development tools and design considerations used in HVAC controls development. Controls development use simulation, lab testing and field trial at different phases of the project cycle to improve control performance and to achieve rapid development. Development starts with simulation to originate and define algorithm concept. The concept is then implemented in a prototype controller, and tested in lab environment. The concept is refined and verified by analyzing lab results. In the final phase of development, controllers with refined and verified algorithms are installed in field trial sites to ensure system integration and to confirm

100

Grundfos HVAC OEM Efficient water hydraulics  

E-Print Network (OSTI)

Grundfos HVAC OEM Efficient water hydraulics for Heat Pumps Anders Mønsted GRUNDFOS Holding A/S Group Technical Key Account Manager HVAC OEM Project Management http://net.grundfos.com/doc/webnet/hv acoem/index.htmlOEM online #12;Introduction Grundfos Company Grundfos HVAC OEM Current Circulator Range

Oak Ridge National Laboratory

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Energirigtige pumpekoblinger i HVAC-systemer  

E-Print Network (OSTI)

Energirigtige pumpekoblinger i HVAC-systemer PSO 2003 - FORSKNING & UDVIKLING I EFFEKTIV energieffektive HVAC-aggregater #12;InformationomProjektnr.:335-021 PROCESSEN: Projektet er gennemført af en reguleringsprincipper, mens Exhausto har leveret HVAC-aggregat og knowhow inden for klimasystemer. Grundfos

102

CALIFORNIA ENERGY Small HVAC Database Of Monitored  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Small HVAC Database Of Monitored Information Database of Compiled of the Integrated Design of Small Commercial HVAC Systems research project. The reports are a result of funding: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

103

CALIFORNIA ENERGY Small HVAC System Design Guide  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Small HVAC System Design Guide DESIGNGUIDELINES October 2003 500;#12;Small HVAC System Design Guide Acknowledgements i Acknowledgements The products and outcomes presented; Darren Goody, PECI, Design Guide review. #12;Small HVAC System Design Guide Preface ii Preface The Small

104

SIMULATION OF RESIDENTIAL HVAC SYSTEM PERFORMANCE  

E-Print Network (OSTI)

1 LBNL-47622 SIMULATION OF RESIDENTIAL HVAC SYSTEM PERFORMANCE Walker, I., Siegel, J ..................................................... 9 #12;3 ABSTRACT In many parts of North America residential HVAC systems are installed outside of the simulations is that they are dynamic - which accounts for cyclic losses from the HVAC system and the effect

105

PROJECT REPORT HVAC EQUIPMENT DEMOGRAPHICS AND CAPACITY  

E-Print Network (OSTI)

PROJECT REPORT HVAC EQUIPMENT DEMOGRAPHICS AND CAPACITY ANALYSIS TOOLS APPLICABLE TO MULTI Commercial HVAC Design Process 12 5.0 Conclusion 18 6.0 References 19 TABLE OF CONTENTS SECTIONS #12;MULTI performance by collectively improving the enve- lope, lighting and HVAC systems. The primary goals of the UC

California at Davis, University of

106

CALIFORNIA ENERGY Small HVAC Problems and Potential  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Small HVAC Problems and Potential Savings Reports Summary of Problems of the Integrated Design of Small Commercial HVAC Systems research project. The reports are a result of funding: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

107

Influence Of Three Dynamic Predictive Clothing Insulation Models On Building Energy Use, HVAC Sizing And Thermal Comfort  

E-Print Network (OSTI)

Weather, Clothing and Thermal Adaptation to Indoor Climate,of Determining Acceptable Thermal Conditions, Building andan Adaptive Model of Thermal Comfort and Preference, Final

Schiavon, Stefano; Lee, Kwang Ho

2013-01-01T23:59:59.000Z

108

Optimization models of gas recovery and gas condensate processing  

Science Conference Proceedings (OSTI)

We present a complex of mathematical models that formalize gas recovery and processing. Optimization problems for gas recovery and gas condensate processing are stated and corresponding solution algorithms are suggested. These mathematical models provide ...

M. Kh. Prilutskii; V. E. Kostyukov

2012-05-01T23:59:59.000Z

109

Analysis of Innovative HVAC System Technologies and Their Application for Office Buildings in Hot and Humid Climates  

E-Print Network (OSTI)

ABSTRACT Analysis of Innovative HVAC System Technologies and Their Application for Office Buildings in Hot and Humid Climates. (December 2010) Oleksandr Tanskyi, B.S., National Technical University of Ukraine; M.S., National Technical University of Ukraine Co-Chairs of Advisory Committee: Dr. David E. Claridge Dr. Michael B. Pate The commercial buildings sector in the United States used 18% (17.93 Quads) of the U.S. primary energy in 2006. Office buildings are the largest single energy consumption category in the commercial buildings sector of the United States with annual energy consumption around 1.1 Quads. Traditional approaches used in commercial building designs are not adequate to save energy in both depth and scale. One of the most effective ways to reduce energy consumption is to improve energy performance of HVAC systems. High-performance HVAC systems and components, as well as application of renewable energy sources, were surveyed for buildings in hot and humid climates. An analysis of performance and energy saving potential estimation for selected HVAC systems in hot and humid climates was developed based on energy consumption simulation models in DOE-2.1E. A calibrated energy consumption model of an existing office building located in the hot and humid climate conditions of Texas was developed. Based on this model, the energy saving potential of the building was estimated. In addition, energy consumption simulation models were developed for a new office building, including simulation of energy saving measures that could be achieved with further improvements of HVAC system above the energy conservation codes requirements. The theoretical minimum energy consumption level for the same office building was estimated for the purpose of evaluating the whole building energy efficiency level. The theoretical minimum energy consumption model of the office building was designed to provide the same level of comfort and services to the building occupants as provided in the actual building simulation model. Finally, the energy efficiency of the building that satisfies valid energy conservation codes and the building with an improved HVAC system was estimated based on theoretically minimum energy consumption level. The analysis provided herein can be used for new building practitioners and existing building owners to evaluate energy reduction potential and the performance of innovative technologies such as dedicated outdoor air system, displacement ventilation, improved cooling system efficiency, air source heat pumps and natural gas heat pumps.

Tanskyi, Oleksandr

2010-12-01T23:59:59.000Z

110

Economic Comparison of HVAC and HVDCSolutions for Large Offshore Wind Farms underSpecial Consideration of Reliability.  

E-Print Network (OSTI)

?? An economic comparison of several HVAC-HVDC transmission systems from large offshore windfarms is presented. The power output from the offshore windfarm is modeled by… (more)

Lazaridis, Lazaros

2005-01-01T23:59:59.000Z

111

Modeling of Solar-Powered Single-Effect Absorption Cooling System and Supermarket Refrigeration/HVAC System.  

E-Print Network (OSTI)

?? This thesis consists of two different research problems. In the first one, the aim is to model and simulate a solar-powered, single-effect, absorption refrigeration… (more)

Bahman, Ammar Mohammad Khalil

2011-01-01T23:59:59.000Z

112

Modeling of Solar-Powered Single-Effect Absorption Cooling System and Supermarket Refrigeration/HVAC System.  

E-Print Network (OSTI)

??This thesis consists of two different research problems. In the first one, the aim is to model and simulate a solar-powered, single-effect, absorption refrigeration system… (more)

Bahman, Ammar

2011-01-01T23:59:59.000Z

113

Reliability and Functional Availability of HVAC Systems  

E-Print Network (OSTI)

This paper presents a model to calculate the reliability and availability of heating, ventilation and air conditioning systems. The reliability is expressed in the terms of reliability, maintainability and decision capability. These terms are a function of the mean time between failure, mean time to repair and decision time. The availability is expressed as an operational and functional availability of the systems. These terms are a function of both the technical and human characteristics to maintain the systems in correct operational state. The result is based on a large amount data from operational organisations, the compulsory inspection of ventilation systems and momentary and continuous measurements made in HVAC-systems.

Myrefelt, S.

2004-01-01T23:59:59.000Z

114

Ameren Illinois (Gas) - Business Efficiency Incentives (Illinois...  

Open Energy Info (EERE)

- 6,000 Gas Furnace Replacement: 200 - 800unit Gas Boiler Tune-Up: 100 - 2400 Steam Trap Survey (HVAC): 30trap (<15 psig) Steam Trap Repair Replacement (HVAC): 100...

115

Software tools for HVAC research  

Science Conference Proceedings (OSTI)

Energy saving methods can be employed to reduce energy consumption in buildings, or improve indoor thermal conditions. An example of those methods is the use of permeable coverings, but there are other important parameters like thermal inertia. To understand ... Keywords: Building, Computer, Design, Energy saving, HVAC, Software tools

José A. Orosa; Armando C. Oliveira

2011-10-01T23:59:59.000Z

116

HVAC equipment replacement for best size and efficiency  

DOE Green Energy (OSTI)

The purpose of this project was to explore the potential benefits of HVAC equipment replacement for buildings owned by the City of Phoenix. The specific research objectives were as follows: Establishment an understanding of the magnitude and sources of saving available through equipment replacement; Establish an economic model for understanding equipment replacement and deciding when equipment should be replaced; Establish technical methods for calculating savings from replacement of various types of equipment; Demonstrate the replacement of a major item of HVAC equipment and document the savings through actual experimentation and measurement; and Provide guidance material for other jurisdictions wishing to investigate equipment replacement. 11 figs., 9 tabs.

Teji, D.S.

1988-02-01T23:59:59.000Z

117

STATE OF CALIFORNIA CERTIFICATE OF COMPLIANCE, PRESCRIPTIVE HVAC ALTERATIONS  

E-Print Network (OSTI)

STATE OF CALIFORNIA CERTIFICATE OF COMPLIANCE, PRESCRIPTIVE HVAC ALTERATIONS CEC-MECH-1C-ALT-HVAC (Revised 07/10) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE MECH-1C-ALT-HVAC Prescriptive HVAC Steps" column below. Note: After installation of HVAC units and/or ducts, the Installation

118

HVAC Technician | Princeton Plasma Physics Lab  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Technician HVAC Technician Department: Facilities Supervisor(s): Tom Ward Staff: L&S 07 Requisition Number: 1300884 Under the supervision of the General Lead Technician and Lead HVAC Technician, the incumbent will be responsible for the installation, preventative maintenance, troubleshooting and repair of various HVAC and refrigeration equipment; local HVAC control systems and ancillary support equipment; and will work with other groups within the Division and throughout the Laboratory to ensure long-term, safe and efficient operation of HVAC and refrigeration systems. All tasks must be completed in a timely, cost efficient manner, support on-going sustainability initiatives and energy efficiency programs at the Laboratory. The incumbent is expected to utilize thorough theoretical knowledge and techniques to accomplish

119

Wireless Temperature Sensors for Improved HVAC Control  

NLE Websites -- All DOE Office Websites (Extended Search)

reliable, and affordable and affordable Wireless Temperature Sensors for Improved HVAC Control An assessment of wireless sensor technology Executive Summary This Technology...

120

HVAC Testing, Adjusting, and Balancing Guideline  

Science Conference Proceedings (OSTI)

This report provides practical guidelines that can be used by power plant personnel to diagnose and troubleshoot heating, ventilating, and air conditioning (HVAC) system and component performance problems.

2001-10-24T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Columbia Water & Light- Residential HVAC Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Columbia Water & Light (CWL) provides an HVAC incentive for residential customers that are replacing an older heating and cooling system. Customers should submit the mechanical permit from a...

122

Real natural gas reservoir data Vs. natural gas reservoir models  

Science Conference Proceedings (OSTI)

The gas reservoir per se model is an exceedingly simple model of a natural gas reservoir designed to develop the physical relationship between ultimate recovery and rate(s) of withdrawal for production regulation policy assessment. To be responsive, ...

Ellis A. Monash; John Lohrenz

1979-03-01T23:59:59.000Z

123

Building Energy Software Tools Directory: HVAC Residential Load...  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Residential Load Calcs HD for the iPad Carmel Software logo HVAC Residential Load Calcs HD is a comprehensive HVAC heating and cooling load calculation application for the...

124

Compression effects on pressure loss in flexible HVAC ducts  

E-Print Network (OSTI)

to Determine Flow Resistance of HVAC Air Ducts and Fittings.Pressure Loss in Flexible HVAC Ducts Bass Abushakra, Ph.D.to Determine Flow Resistance of HVAC Air Ducts and Fittings.

Abushakra, Bass; Walker, Iain S.; Sherman, Max H.

2002-01-01T23:59:59.000Z

125

Fouling of HVAC fin and tube heat exchangers  

E-Print Network (OSTI)

air ? air ? part ? part FPI HVAC REFERENCES Anonymous, 1987,LBNL-47668 Fouling of HVAC Fin and Tube Heat ExchangersCIEE SPONSOR. FOULING OF HVAC FIN AND TUBE HEAT EXCHANGERS

Siegel, Jeffrey; Carey, Van P.

2001-01-01T23:59:59.000Z

126

Measuring rates of outdoor airflow into HVAC systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Measuring rates of outdoor airflow into HVAC systems Title Measuring rates of outdoor airflow into HVAC systems Publication Type Journal Article LBNL Report Number LBNL-51583 Year...

127

Report on HVAC Option Selections for a Relocatable Classroom...  

NLE Websites -- All DOE Office Websites (Extended Search)

Report on HVAC Option Selections for a Relocatable Classroom Energy and Indoor Environmental Quality Field Study Title Report on HVAC Option Selections for a Relocatable Classroom...

128

HVAC Water Heater Field Tests Research Project | Department of...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Water Heater Field Tests Research Project HVAC Water Heater Field Tests Research Project The U.S. Department of Energy is currently conducting research into heating,...

129

HVAC system study: a data-driven approach.  

E-Print Network (OSTI)

?? The energy consumed by heating, ventilating, and air conditioning (HVAC) systems has increased in the past two decades. Thus, improving efficiency of HVAC systems… (more)

Xu, Guanglin

2012-01-01T23:59:59.000Z

130

Improving Relocatable Classroom HVAC For Improved IEQ And Energy...  

NLE Websites -- All DOE Office Websites (Extended Search)

Improving Relocatable Classroom HVAC For Improved IEQ And Energy Efficiency Title Improving Relocatable Classroom HVAC For Improved IEQ And Energy Efficiency Publication Type...

131

DOE Convening Report on Certification of Commercial HVAC and...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Convening Report on Certification of Commercial HVAC and CRE Products DOE Convening Report on Certification of Commercial HVAC and CRE Products This document is the convening...

132

Ventilation, temperature, and HVAC characteristics in small and...  

NLE Websites -- All DOE Office Websites (Extended Search)

Ventilation, temperature, and HVAC characteristics in small and medium commercial buildings in California Title Ventilation, temperature, and HVAC characteristics in small and...

133

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives < Back...

134

System-Level Monitoring and Diagnosis of Building HVAC System.  

E-Print Network (OSTI)

??Heating, ventilation, and air conditioning (HVAC) is an indoor environmental technology that is extensively instrumented for large-scale buildings. Among all subsystems of buildings, the HVAC… (more)

Wu, Siyu

2013-01-01T23:59:59.000Z

135

Monitoring-based HVAC Commissioning of an Existing Office Building...  

NLE Websites -- All DOE Office Websites (Extended Search)

Monitoring-based HVAC Commissioning of an Existing Office Building for Energy Efficiency Title Monitoring-based HVAC Commissioning of an Existing Office Building for Energy...

136

Chapter 5: Lighting, HVAC, and Plumbing | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5: Lighting, HVAC, and Plumbing Chapter 5: Lighting, HVAC, and Plumbing Chapter 5 of the LANL Sustainable Design Guide with guidelines for developing sustainable, healthy,...

137

New and Underutilized Technology: HVAC Occupancy Sensors | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Occupancy Sensors New and Underutilized Technology: HVAC Occupancy Sensors October 4, 2013 - 4:20pm Addthis The following information outlines key deployment considerations...

138

Distributed Control of HVAC&R Networks  

E-Print Network (OSTI)

Heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems are a major component of worldwide energy consumption, and frequently consist of complex networks of interconnected components. The ubiquitous nature of these systems suggests that improvements in their energy efficiency characteristics can have significant impact on global energy consumption. The complexity of the systems, however, means that decentralized control schemes will not always suffice to balance competing goals of energy efficiency and occupant comfort and safety. This dissertation proposes control solutions for three facets of this problem. The first is a cascaded control architecture for actuators, such as electronic expansion valves, that provides excellent disturbance rejection and setpoint tracking characteristics, as well as partial nonlinearity compensation without a compensation model. The second solution is a hierarchical control architecture for multiple-evaporator vapor compression systems that uses model predictive control (MPC) at both the supervisory and component levels. The controllers leverage the characteristics of MPC to balance energy efficiency with occupant comfort. Since the local controllers are decentralized, the architecture retains a degree of modularity—changing one component does not require changing all controllers. The final contribution is a new distributed optimization algorithm that is rooted in distributed MPC and is especially motivated by HVAC&R systems. This algorithm allows local level optimizers to iterate to a centralized solution. The optimizers have no knowledge of any plant other than the plant they are associated with, and only need to communicate with their immediate neighbors. The efficacy of the algorithm is displayed with two sets of examples. One example is simulation based, wherein a building is modeled in the EnergyPlus software suite. The other is an experimental example. In this example, the algorithm is applied to a multiple evaporator vapor compression system. In both cases the design method is discussed, and the ability of the algorithm to reduce energy consumption when properly applied is demonstrated.

Elliott, Matthew Stuart

2013-08-01T23:59:59.000Z

139

Commercial Building HVAC: How it Affects People  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Building HVAC: How it Affects People Commercial Building HVAC: How it Affects People Speaker(s): William Fisk Date: November 13, 2000 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: David Faulkner Commercial building heating, ventilating, and air conditioning (HVAC) systems are designed primarily to maintain a reasonable level of thermal comfort while limiting first costs and energy consumption. However, research conducted predominately within the last decade suggests that commercial building HVAC significantly influences human outcomes other than thermal comfort, including the health, satisfaction, and work performance of the building's occupants. This presentation will review the relationships of these outcomes with HVAC system type, filtration system efficiency, indoor air temperature, and outside air ventilation rate.

140

Post-Retrocommissioning HVAC Operations Monitoring Using Enterprise-Wide energy Management System  

E-Print Network (OSTI)

Since 2004, the County of Los Angeles have retrocommissioned over 4 million square feet and additional RCx work is underway. The scope of the HVAC retrocommissioning (RCs) involved systematic investigation of mechanical, electrical and controls components/systems to diagnose and resolve root causes of operational deficiencies. During the implementation phase, new energy efficiency measures were installed, sequence of operations were optimized and functionally tested. System-level benchmark models for HVAC systems were developed based on optimized runs of eQUEST energy models and parametrically integrated into the County owned web-based Enterprise Energy Management Information Systems (EEMIS) with Itron/Silicon Energy EEM Suite backbone for the purpose of monitoring the operations of the HVAC systems. The paper and presentation describes the HVAC RCx process to optimize operations, cost and savings associated with this project and key operational changes to sustain optimized operations without sacrificing tenant comfort.

Amarnani, N.; Roberts, B.; Choy, H.

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Modeling and Measurement Constraints in Fault Diagnostics for...  

NLE Websites -- All DOE Office Websites (Extended Search)

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Title Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Publication Type Journal...

142

Ventilation, temperature, and HVAC characteristics in small and medium  

NLE Websites -- All DOE Office Websites (Extended Search)

Ventilation, temperature, and HVAC characteristics in small and medium Ventilation, temperature, and HVAC characteristics in small and medium commercial buildings in California Title Ventilation, temperature, and HVAC characteristics in small and medium commercial buildings in California Publication Type Journal Article Refereed Designation Refereed Year of Publication 2012 Authors Bennett, Deborah H., William J. Fisk, Michael G. Apte, X. Wu, Amber L. Trout, David Faulkner, and Douglas P. Sullivan Journal Indoor Air Volume 22 Issue 4 Pagination 309-20 Abstract This field study of 37 small and medium commercial buildings throughout California obtained information on ventilation rate, temperature, and heating, ventilating, and air-conditioning (HVAC) system characteristics. The study included seven retail establishments; five restaurants; eight offices; two each of gas stations, hair salons, healthcare facilities, grocery stores, dental offices, and fitness centers; and five other buildings. Fourteen (38%) of the buildings either could not or did not provide outdoor air through the HVAC system. The air exchange rate averaged 1.6 (s.d. = 1.7) exchanges per hour and was similar between buildings with and without outdoor air supplied through the HVAC system, indicating that some buildings have significant leakage or ventilation through open windows and doors. Not all buildings had sufficient air exchange to meet ASHRAE 62.1 Standards, including buildings used for fitness centers, hair salons, offices, and retail establishments. The majority of the time, buildings were within the ASHRAE temperature comfort range. Offices were frequently overcooled in the summer. All of the buildings had filters, but over half the buildings had a filter with a minimum efficiency reporting value rating of 4 or lower, which are not very effective for removing fine particles. PRACTICAL IMPLICATIONS: Most U.S. commercial buildings (96%) are small- to medium-sized, using nearly 18% of the country's energy, and sheltering a large population daily. Little is known about the ventilation systems in these buildings. This study found a wide variety of ventilation conditions, with many buildings failing to meet relevant ventilation standards. Regulators may want to consider implementing more complete building inspections at commissioning and point of sale.

143

Building America Expert Meeting Report: Transitioning Traditional HVAC Contractors to Whole House Performance Contractors  

DOE Green Energy (OSTI)

This report outlines findings resulting from a U.S. Department of Energy Building America expert meeting to determine how HVAC companies can transition from a traditional contractor status to a service provider for whole house energy upgrade contracting. IBACOS has embarked upon a research effort under the Building America Program to understand business impacts and change management strategies for HVAC companies. HVAC companies can implement these strategies in order to quickly transition from a 'traditional' heating and cooling contractor to a service provider for whole house energy upgrade contracting. Due to HVAC service contracts, which allow repeat interaction with homeowners, HVAC companies are ideally positioned in the marketplace to resolve homeowner comfort issues through whole house energy upgrades. There are essentially two primary ways to define the routes of transition for an HVAC contractor taking on whole house performance contracting: (1) Sub-contracting out the shell repair/upgrade work; and (2) Integrating the shell repair/upgrade work into their existing business. IBACOS held an Expert Meeting on the topic of Transitioning Traditional HVAC Contractors to Whole House Performance Contractors on March 29, 2011 in San Francisco, CA. The major objectives of the meeting were to: Review and validate the general business models for traditional HVAC companies and whole house energy upgrade companies Review preliminary findings on the differences between the structure of traditional HVAC Companies and whole house energy upgrade companies Seek industry input on how to structure information so it is relevant and useful for traditional HVAC contractors who are transitioning to becoming whole house energy upgrade contractors Seven industry experts identified by IBACOS participated in the session along with one representative from the National Renewable Energy Laboratory (NREL). The objective of the meeting was to validate the general operational profile of an integrated whole house performance contracting company and identify the most significant challenges facing a traditional HVAC contractor looking to transition to a whole house performance contractor. To facilitate the discussion, IBACOS divided the business operations profile of a typical integrated whole house performance contracting company (one that performs both HVAC and shell repair/upgrade work) into seven Operational Areas with more detailed Business Functions and Work Activities falling under each high-level Operational Area. The expert panel was asked to review the operational profile or 'map' of the Business Functions. The specific Work Activities within the Business Functions identified as potential transition barriers were rated by the group relative to the value in IBACOS creating guidance ensuring a successful transition and the relative difficulty in executing.

Burdick, A.

2011-10-01T23:59:59.000Z

144

Residential HVAC Indoor Air Quality(ASHRAE 62.2)  

E-Print Network (OSTI)

Residential HVAC && Indoor Air Quality(ASHRAE 62.2) Tav Commins #12;Contact Information · Energy construction, Additions /Alterations · Nonresidential and Residential #12;Residential HVAC && Indoor Air Quality(ASHRAE 62.2) ·HVAC EfficiencyHVAC Efficiency ·Quality Installation (HERS Measures) S li b HERS R t

145

Cooling and Dehumidification HVAC Technology for 1990s  

E-Print Network (OSTI)

Desiccant Cooling and Dehumidification HVAC Technology for 1990s HVAC: Heating, Ventilation Research Trusts SERI #12;Challenges Facing HVAC Industry in 1990's * Reduction of CFCs * Indoor air quality to solve the problems of the HVAC industry faced in1990's for space conditioning. SERI #12;l- = m mN a- mg

Oak Ridge National Laboratory

146

2013 Energy Code Changes That Effect the HVAC  

E-Print Network (OSTI)

2013 Energy Code Changes That Effect the HVAC Industry Tav Commins Mechanical Engineer California Energy Commission #12;HVAC Mandatory Measures For All Newly Installed Residential HVAC Systems (New Watt Draw at .58 W/CFM, or (return duct and filter sizing) MERV 6 Filter #12;Residential HVAC Measures

California at Davis, University of

147

CALIFORNIA ENERGY Large HVAC Field and Baseline Data  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Large HVAC Field and Baseline Data Field Data Collection: Site Survey of the Integrated Design of Large Commercial HVAC Systems research project. The reports are a result of funding Design of Large Commercial HVAC Systems Integrated Design of Small Commercial HVAC Systems Integrated

148

Manhole Event Gas Explosion Modeling  

Science Conference Proceedings (OSTI)

This report provides the second update on work reported in the December 2007 report, Manhole Event Risk Management: Mitigation Strategies (1013886), and the March 2008 report, Manhole Event Gas Explosion Modeling: Phase I (1016476). The report summarizes the status of the software development effort and identifies some unexpected phenomena, difficulties, and explosion characteristics. Theories to explain these phenomena are proposed, and code modifications are outlined that achieve reasonable agreement b...

2008-12-22T23:59:59.000Z

149

Manhole Event Gas Explosion Modeling  

Science Conference Proceedings (OSTI)

This report provides an update on work reported in December 2007 in Manhole Event Risk Management: Mitigation Strategies (EPRI report 1013886). It summarizes software development efforts to model gas-related explosion events in manholes and identifies some unexpected phenomena, difficulties, and explosion characteristics revealed during tests at the Lenox facility. The report proposes theories to explain these phenomena and outlines code modifications to achieve reasonable agreement between computed and ...

2008-03-26T23:59:59.000Z

150

Optimization Control Strategies for HVAC Terminal Boxes  

E-Print Network (OSTI)

The HVAC terminal boxes are one of the major building HVAC components. They directly impact the building room comfort conditions and the energy costs. How to operate the box in a highly energy efficient way and maintain the room comfort level is an important topic in today's building energy management and HVAC control field. The authors developed novel optimized control strategies and operation schedules for the terminal boxes for both occupied and non-occupied hours. The optimized control schedules were implemented in a medical complex during the commissioning. This not only improved the building comfort conditions but also reduced the energy costs.

Zhu, Y.; Batten, T.; Noboa, H.; Claridge, D. E.; Turner, W. D.; Liu, M.; Zhou, J.; Cameron, C.; Keeble, D.; Hirchak, R.

2000-01-01T23:59:59.000Z

151

Salsbury and Diamond: Automated Testing of HVAC Systems for Commissioning -1 -Automated Testing of HVAC Systems for Commissioning  

E-Print Network (OSTI)

and Diamond: Automated Testing of HVAC Systems for Commissioning - 1 - Automated Testing of HVAC Systems This paper describes an approach to the automation of the commissioning of HVAC systems. The approach of many HVAC systems is limited more by poor installation, commissioning, and maintenance than by poor

152

Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable-Speed-Drive Chillers  

E-Print Network (OSTI)

resource/24/ ASHRAE handbook – HVAC systems and equipments.Efficient Cleanrooms Efficient HVAC Systems: Variable-Speed-Efficient Cleanrooms Efficient HVAC Water Systems: Variable-

Xu, Tengfang

2005-01-01T23:59:59.000Z

153

Laboratory measurement of secondary pollutant yields from ozone reaction with HVAC filters.  

E-Print Network (OSTI)

from Ozone Reaction with HVAC Filters Hugo Destaillats,from Ozone Reaction with HVAC Filters Hugo Destaillatsfrom Ozone Reaction with HVAC Filters Hugo Destaillats

Destaillats, Hugo

2012-01-01T23:59:59.000Z

154

Case study field evaluation of a systems approach to retrofitting a residential HVAC system  

E-Print Network (OSTI)

Practices for Residential HVAC Systems”. Boston, MA. Jump,techniques for measuring HVAC grille air flows". ASHRAEPractices Guide for Residential HVAC Retrofits. LBNL 53592.

Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

2003-01-01T23:59:59.000Z

155

Home Energy Article: A Systems Approach to Retrofitting Residential HVAC Systems  

E-Print Network (OSTI)

to Retrofitting a Residential HVAC System, Lawrence Berkeleyducts. New downsized ducts and HVAC equipment. The ducts areto Retrofitting Residential HVAC Systems J.A. McWilliams and

McWilliams, Jennifer A.; Walker, Iain S.

2005-01-01T23:59:59.000Z

156

An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings  

E-Print Network (OSTI)

and Judkoff, R. 2002. IEA HVAC BESTEST volume 1, Technicaland Judkoff, R. 2004. IEA HVAC BESTEST volume 2, TechnicalOF INNOVATIVE INTEGRATED HVAC SYSTEMS IN BUILDINGS Marija

Trcka, Marija

2010-01-01T23:59:59.000Z

157

Comparisons of HVAC Simulations between EnergyPlus and DOE-2.2 for Data Centers  

E-Print Network (OSTI)

ABORATORY Comparisons of HVAC Simulations between EnergyPlusemployer. Comparisons of HVAC Simulations between EnergyPlusThis paper compares HVAC simulations between EnergyPlus and

Hong, Tianzhen

2009-01-01T23:59:59.000Z

158

Improving Indoor Environmental Quality And Energy Performance Of Modular Classroom HVAC Systems  

E-Print Network (OSTI)

Schools (CHPS). 2002. "HVAC Best Practices Manual." CHPSOF MODULAR CLASSROOM HVAC SYSTEMS Michael G. APTE Ph.D. MPHRelocatable Classroom HVAC for Improved IEQ and Energy

Apte, Michael G.; Spears, Michael; Lai, Chi-Ming; Shendell, Derek G.

2005-01-01T23:59:59.000Z

159

Investigation of IAQ-Relevant Surface Chemistry and Emissions on HVAC Filter Materials  

E-Print Network (OSTI)

VOCs emitted by reactions of HVAC filters with ozone usingChemistry and Emissions on HVAC Filter Materials HugoChemistry and Emissions on HVAC Filter Materials Authors:

Destaillats, Hugo

2010-01-01T23:59:59.000Z

160

HVAC Equipment Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Equipment Rebate Program HVAC Equipment Rebate Program HVAC Equipment Rebate Program < Back Eligibility Agricultural Commercial Industrial Installer/Contractor Institutional Multi-Family Residential Nonprofit Schools Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Heat Pumps Maximum Rebate Rebates of greater than $5,000 require pre-approval Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Varies depending on technology and efficiency Provider Efficiency Vermont NOTE: Rebate reservations are required for all boiler and furnace projects. Efficiency Vermont offers rebates for commercial installations of high-efficiency HVAC equipment and controls. For businesses and purchases

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

HVAC Energy Recovery Design and Economic Evaluation  

E-Print Network (OSTI)

ENRECO has prepared this paper on HVAC energy recovery to provide the engineer with an overview of the design engineering as well as the economic analysis considerations necessary to evaluate the potential benefits of energy recovery.

Kinnier, R. J.

1979-01-01T23:59:59.000Z

162

Wireless Demand Response Controls for HVAC  

NLE Websites -- All DOE Office Websites (Extended Search)

Wireless Demand Response Controls for HVAC Speaker(s): Clifford Federspiel Date: June 22, 2006 - 12:00pm Location: 90-3148 Seminar HostPoint of Contact: Richard Diamond Peng Xu We...

163

Model Documentation Report: Natural Gas Transmission and ...  

U.S. Energy Information Administration (EIA)

National Energy Modeling System: An Overview 2009,” DOE/EIA-0581(2009), October 2009. 8 Natural gas exports are also accounted for within the model. January 2013

164

Quantitative Methods for Comparing Different HVAC Control Schemes  

E-Print Network (OSTI)

Experimentally comparing the energy usage and comfort characteristics of different controllers in heating, ventilation, and air-conditioning (HVAC) systems is difficult because variations in weather and occupancy conditions preclude the possibility of establishing equivalent experimental conditions across the order of hours, days, and weeks. This paper is concerned with defining quantitative metrics of energy usage and occupant comfort, which can be computed and compared in a rigorous manner that is capable of determining whether differences between controllers are statistically significant in the presence of such environmental fluctuations. Experimental case studies are presented that compare two alternative controllers (a schedule controller and a hybrid system learning-based model predictive controller) to the default controller in a building-wide HVAC system. Lastly, we discuss how our proposed methodology may also be able to quantify the efficiency of other building automation systems.

Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

2012-01-01T23:59:59.000Z

165

Plutonium Finishing Plant (PFP) HVAC System Component Index  

SciTech Connect

This document lists safety class (SC) and safety significant (SS) components for the Heating Ventilation Air Conditioning (HVAC) and specifies the critical characteristics for Commercial Grade Items (CGI), as required by HNF-PRO-268 and HNF-PRO-18 19. These are the minimum specifications that the equipment must meet in order to properly perform its safety function. There may be several manufacturers or models that meet the critical characteristics for any one item. The Plutonium Finishing Plant (PFP) HVAC System includes sub-systems 25A through 25K. Specific system boundaries and justifications are contained in HNF-SD-CP-SDD-005, ''Definition and Means of Maintaining the Ventilation System Confinement Portion of the PFP Safety Envelope.'' The procurement requirements associated with the system necessitates procurement of some system equipment as Commercial Grade Items in accordance with HNF-PRO-268, ''Control of Purchased Items and Services.''

DIAZ, E.N.

2000-03-30T23:59:59.000Z

166

HVAC Fans and Dampers Maintenance Guide  

Science Conference Proceedings (OSTI)

Heating, ventilation, and air conditioning (HVAC) systems serve an important function in nuclear power plants because these systems are responsible for maintaining many environmental conditions throughout the facility. Failure of these components can induce undesirable radiological conditions and stressful working conditions, and can compromise the life of qualified equipment. Some HVAC fan and damper failures are preventable by monitoring operating parameters and performing recommended maintenance activ...

1999-08-26T23:59:59.000Z

167

Mathematical models of natural gas consumption  

E-Print Network (OSTI)

Mathematical models of natural gas consumption Kristian Sabo, Rudolf Scitovski, Ivan of natural gas consumption Kristian Sabo, Rudolf Scitovski, Ivan Vazler , Marijana Zeki-Susac ksabo of natural gas consumption hourly fore- cast on the basis of hourly movement of temperature and natural gas

Scitovski, Rudolf

168

An Evaluation of the HVAC Load Potential for Providing Load Balancing Service  

Science Conference Proceedings (OSTI)

This paper investigates the potential of providing aggregated intra-hour load balancing services using heating, ventilating, and air-conditioning (HVAC) systems. A direct-load control algorithm is presented. A temperature-priority-list method is used to dispatch the HVAC loads optimally to maintain consumer-desired indoor temperatures and load diversity. Realistic intra-hour load balancing signals were used to evaluate the operational characteristics of the HVAC load under different outdoor temperature profiles and different indoor temperature settings. The number of HVAC units needed is also investigated. Modeling results suggest that the number of HVACs needed to provide a {+-}1-MW load balancing service 24 hours a day varies significantly with baseline settings, high and low temperature settings, and the outdoor temperatures. The results demonstrate that the intra-hour load balancing service provided by HVAC loads meet the performance requirements and can become a major source of revenue for load-serving entities where the smart grid infrastructure enables direct load control over the HAVC loads.

Lu, Ning

2012-09-30T23:59:59.000Z

169

Building Technologies Office: HVAC Optimized Heat Exchangers Research  

NLE Websites -- All DOE Office Websites (Extended Search)

Optimized Heat Optimized Heat Exchangers Research Project to someone by E-mail Share Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Facebook Tweet about Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Twitter Bookmark Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Google Bookmark Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Delicious Rank Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Digg Find More places to share Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research Building Envelope Research

170

Measuring advances in HVAC distribution system designs  

Science Conference Proceedings (OSTI)

Substantial commercial building energy savings have been achieved by improving the performance of the HVAC distribution system. The energy savings result from distribution system design improvements, advanced control capabilities, and use of variable-speed motors. Yet, much of the commercial building stock remains equipped with inefficient systems. Contributing to this is the absence of a definition for distribution system efficiency as well as the analysis methods for quantifying performance. This research investigates the application of performance indices to assess design advancements in commercial building thermal distribution systems. The index definitions are based on a first and second law of thermodynamics analysis of the system. The second law or availability analysis enables the determination of the true efficiency of the system. Availability analysis is a convenient way to make system efficiency comparisons since performance is evaluated relative to an ideal process. A TRNSYS simulation model is developed to analyze the performance of two distribution system types, a constant air volume system and a variable air volume system, that serve one floor of a large office building. Performance indices are calculated using the simulation results to compare the performance of the two systems types in several locations. Changes in index values are compared to changes in plant energy, costs, and carbon emissions to explore the ability of the indices to estimate these quantities.

Franconi, Ellen

1998-07-01T23:59:59.000Z

171

Building Technologies Office: HVAC and Water Heater Field Tests Research  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC and Water Heater HVAC and Water Heater Field Tests Research Project to someone by E-mail Share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Facebook Tweet about Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Twitter Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Google Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Delicious Rank Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Digg Find More places to share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research

172

Building Technologies Office: Recovery Act-Funded HVAC Research Projects  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Research Projects to someone by E-mail HVAC Research Projects to someone by E-mail Share Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Facebook Tweet about Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Twitter Bookmark Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Google Bookmark Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Delicious Rank Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Digg Find More places to share Building Technologies Office: Recovery Act-Funded HVAC Research Projects on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research Building Envelope Research Windows, Skylights, & Doors Research Space Heating & Cooling Research

173

Mapping Hvac Systems for Simulation In EnergyPlus  

NLE Websites -- All DOE Office Websites (Extended Search)

Mapping Hvac Systems for Simulation In EnergyPlus Title Mapping Hvac Systems for Simulation In EnergyPlus Publication Type Conference Paper LBNL Report Number LBNL-5565E Year of...

174

Recovery Act-Funded HVAC projects | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC projects Recovery Act-Funded HVAC projects The U.S. Department of Energy was allocated funding from the American Recovery and Reinvestment Act to conduct research into...

175

Issue #3: HVAC Proper Installation Energy Savings: Over-Promising...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3: HVAC Proper Installation Energy Savings: Over-Promising or Under-Delivering? Issue 3: HVAC Proper Installation Energy Savings: Over-Promising or Under-Delivering? What energy...

176

Decentralized nonlinear adaptive control of an HVAC system  

Science Conference Proceedings (OSTI)

This paper presents a new decentralized nonlinear adaptive controller (DNAC) for a heating, ventilating, and air conditioning (HVAC) system capable of maintaining comfortable conditions under varying thermal loads. In this scheme, an HVAC system is considered ...

Zhang Huaguang; Lilong Cai

2002-11-01T23:59:59.000Z

177

Fouling of HVAC fin and tube heat exchangers  

E-Print Network (OSTI)

Methods to Maintain Heat Exchanger Coil Cleanliness, ASHRAEof HVAC Fin and Tube Heat Exchangers Jeffrey Siegel and VanOF HVAC FIN AND TUBE HEAT EXCHANGERS Jeffrey Siegel 1,2 and

Siegel, Jeffrey; Carey, Van P.

2001-01-01T23:59:59.000Z

178

Chapter 5: Lighting, HVAC, and Plumbing  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

: Lighting, : Lighting, HVAC, and Plumbing High-Performance Engineering Design Lighting System Design Mechanical System Design Central Plant Systems Plumbing and Water Use Building Control Systems Electrical Power Systems Metering LANL | Chapter 5 High-Performance Engineering Design Lighting, HVAC, and Plumbing By now, the building envelope serves multiple roles. It protects the occupants from changing weather condi- tions and it plays a key part in meeting the occupants' comfort needs. The heating, ventilating, air-conditioning, and lighting (HVAC&L) systems complement the archi- tectural design, govern the building's operation and maintenance costs, and shape the building's long-term environmental impact. The architectural design maximizes the potential for a high-performance building, but it is the

179

Indoor Air Quality Impacts of Residential HVAC Systems ...  

Science Conference Proceedings (OSTI)

Page 1. NISTIR 5559 Indoor Air Quality Impacts of Residential HVAC Systems Phase 11.AReport: Baseline and Preliminary Simulations ...

1997-09-03T23:59:59.000Z

180

OBSERVE: Occupancy-Based System for Efficient Reduction of HVAC Energy  

E-Print Network (OSTI)

control conditioning strategies. Using strategies based on sensor network occupancy model predictions, weOBSERVE: Occupancy-Based System for Efficient Reduction of HVAC Energy Varick L. Erickson, Miguel Á Descriptors I.6.5 [Simulation and Modeling]: Model Development; J.7 [Computers In Other Systems]: Command

Cerpa, Alberto E.

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Handover Performance of HVAC Duct Based Indoor Wireless Networks  

E-Print Network (OSTI)

Handover Performance of HVAC Duct Based Indoor Wireless Networks A. E. Xhafa, P. Sonthikorn, and O in indoor wireless net- works (IWN) that use heating, ventilation, and air conditioning (HVAC) ducts.e., new call blocking and handover dropping probabilities, of an IWN that uses HVAC ducts are up to 6

Stancil, Daniel D.

182

Monitoring-based HVAC Commissioning of an Existing Office  

E-Print Network (OSTI)

LBNL-5940E Monitoring-based HVAC Commissioning of an Existing Office Building for Energy Efficiency thereof or The Regents of the University of California. #12;1 Monitoring-based HVAC Commissioning@lbl.gov, Tel: 1-510-486-4921 Abstract The performance of Heating, Ventilation and Air Conditioning (HVAC

183

Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings  

E-Print Network (OSTI)

Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings Tom Rogg REU Student to assist HVAC has the potential to significantly reduce life cycle cost and energy consumption and electrical system that will tie thermostats to controlled valves in the actual HVAC system. Based on results

Mountziaris, T. J.

184

Long Range Passive UHF RFID System Using HVAC Ducts  

E-Print Network (OSTI)

INVITED P A P E R Long Range Passive UHF RFID System Using HVAC Ducts To provide a potential communications channel, HVAC ducts can function as electromagnetic waveguides; a 30-m read range has been-conditioning (HVAC) ducts as a potential communication channel between passive ultrahigh-frequency (UHF) radio

Hochberg, Michael

185

Atmospheric Environment 41 (2007) 31513160 Ozone removal by HVAC filters  

E-Print Network (OSTI)

Atmospheric Environment 41 (2007) 3151­3160 Ozone removal by HVAC filters P. Zhao, J.A. Siegel�, R May 2006; accepted 14 June 2006 Abstract Residential and commercial HVAC filters that have been loaded of the relative importance of HVAC filters as a removal mechanism for ozone in residential and commercial

Siegel, Jeffrey

186

An update on acoustics designs for HVAC (Engineering) K. Marriott  

E-Print Network (OSTI)

An update on acoustics designs for HVAC (Engineering) K. Marriott IOA, 29a Ashburton Road, Croydon and Air Conditioning (HVAC) engineer is to engineer ways for keeping these factors under control the HVAC engineer's environmental requirements while minimizing noise generated in the process considering

Paris-Sud XI, Université de

187

Deposition of Biological Aerosols on HVAC Heat Exchangers  

E-Print Network (OSTI)

LBNL-47669 Deposition of Biological Aerosols on HVAC Heat Exchangers Jeffrey Siegel and Iain Walker of Biological Aerosols on HVAC Heat Exchangers Jeffrey A. Siegel Iain S. Walker, Ph.D. ASHRAE Student Member that are found in commercial and residential HVAC systems of 1 - 6 m/s (200 - 1200 ft/min), particle diameters

188

MATERIALS AND INFORMATION FLOWS FOR HVAC DUCTWORK FABRICATION AND SITE  

E-Print Network (OSTI)

MATERIALS AND INFORMATION FLOWS FOR HVAC DUCTWORK FABRICATION AND SITE INSTALLATION Matt Holzemer,1, and air-conditioning (HVAC) systems requires a set of complex activities and handoffs between multiple architecture-, engineering-, and construction practitioners. This paper highlights one part of the HVAC

Tommelein, Iris D.

189

Department of Mechanical Engineering Spring 2012 HVAC Filter Sensor -Global  

E-Print Network (OSTI)

PENNSTATE Department of Mechanical Engineering Spring 2012 HVAC Filter Sensor - Global Overview The purpose of this project is to develop a heating, ventilation, and air conditioning (HVAC) monitoring a residential, forced flow, multi-zone HVAC filter needs to be replaced, and then alerts the users

Demirel, Melik C.

190

SMUD's HVAC Programs Ravi Patel-Program Planning  

E-Print Network (OSTI)

1 SMUD's HVAC Programs 5-7-13 Ravi Patel- Program Planning Bruce Baccei- R&D #12;SMUD's Residential contractors trained and BPI certified ­ Majority were pushing only HVAC; now driving the HPP · Program encourages more HVAC replacements to occur through HPP ­ Move away from stand alone programs ­ Start

California at Davis, University of

191

Continued on next page A letter explaining the 2005 HVAC  

E-Print Network (OSTI)

Continued on next page A letter explaining the 2005 HVAC Change-out to consumers is available this bulletin, or downloaded from the 2005 HVAC Change out Information website at: www.energy.ca.gov/title24 duct sealing requirements for HVAC change-outs in existing homes become effective October 1, 2005

192

Proceedings: Indoor Air 2005 OZONE REMOVAL BY RESIDENTIAL HVAC FILTERS  

E-Print Network (OSTI)

Proceedings: Indoor Air 2005 2366 OZONE REMOVAL BY RESIDENTIAL HVAC FILTERS P Zhao1,2 , JA Siegel1, Austin, Texas 78758, USA ABSTRACT HVAC filters have a significant influence on indoor air quality% for Filter #2 at a face velocity of 0.81 cm/s. The potential for HVAC filters to affect ozone concentrations

Siegel, Jeffrey

193

A PDI for your HVAC System  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8/3/2012 Technical Approach Develop a PDI for HVAC PDI focus is on Inspecting Installation - a $10 Chinese sweatshop t-shirt gets a QA/QC sticker, why not a $10k HVAC system? Develop & require diagnostics that confirm good installations: - Air flow, duct leakage, refrigerant charge, delivered temperatures, system pressures, filter requirements, fan power, noise - On board diagnostics (OBD) for flow, pressures, fan power, charge Make it a warranty requirement, code requirement, permit requirement, etc. Recommended Guidance Develop the PDI checklist and label (include target and system test results) - External Tests: duct leaks - Internal Tests: OBD for system pressures, air flow, charge, fan power - Labels: Certify tight equipment

194

Agegraphic Chaplygin gas model of dark energy  

E-Print Network (OSTI)

We establish a connection between the agegraphic models of dark energy and Chaplygin gas energy density in non-flat universe. We reconstruct the potential of the agegraphic scalar field as well as the dynamics of the scalar field according to the evolution of the agegraphic dark energy. We also extend our study to the interacting agegraphic generalized Chaplygin gas dark energy model.

Ahmad Sheykhi

2010-02-07T23:59:59.000Z

195

Application of Functional Link Neural Network to HVAC Thermal Dynamic System Identification  

E-Print Network (OSTI)

Abstract — Recent efforts to incorporate aspects of artificial intelligence into the design and operation of automatic control systems have focused attention on techniques such as fuzzy logic, artificial neural networks, and expert systems. The use of computers for direct digital control highlights the recent trend toward more effective and efficient heating, ventilating, and airconditioning (HVAC) control methodologies. Researchers in the HVAC field have stressed the importance of self learning in building control systems and have encouraged further studies in the integration of optimal control and other advanced techniques into the formulation of such systems. Artificial neural networks can also be used to emulate the plant dynamics, in order to estimate future plant outputs and obtain plant input/output sensitivity information for on-line neural control adaptation. This paper describes a functional link neural network approach to performing the HVAC thermal dynamic system identification. Methodologies to reduce inputs of the functional link network to reduce the complexity and speed up the training speed will be presented. Analysis and comparison between the functional link network approach and the conventional network approach for the HVAC thermal modeling will also be presented. Index Terms—Functional link, HVAC, intelligent control, neural network, system identification.

Jason Teeter; Mo-yuen Chow; Senior Member

1998-01-01T23:59:59.000Z

196

Questar Gas- Commercial Energy Efficiency Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Questar Gas provides rebates to its business customers for installing energy efficient food service equipment, laundry equipment, HVAC and water heating equipment, and certain weatherization...

197

Occupancy based demand response HVAC control strategy  

Science Conference Proceedings (OSTI)

Heating, cooling and ventilation accounts for 30% energy usage and for 50% of the electricity usage in the United States. Currently, most modern buildings still condition rooms assuming maximum occupancy rather than actual usage. As a result, rooms are ... Keywords: HVAC, demand response, energy savings, occupancy, ventilation

Varick L. Erickson; Alberto E. Cerpa

2010-11-01T23:59:59.000Z

198

Realt-Time Building Occupancy Sensing for Supporting Demand Driven HVAC Operations  

E-Print Network (OSTI)

Accurate knowledge of localised and real-time occupancy numbers can have compelling control applications for Heating, Ventilation and Air-conditioning (HVAC) systems. However, a precise and reliable measurement of occupancy still remains difficult. Existing technologies are plagued with a number of issues ranging from unreliable data, maintaining privacy and sensor drift. More effective control of HVAC systems may be possible using a smart sensing network for occupancy detection. A low-cost and non-intrusive sensor network is deployed in an open-plan office, combining information such as sound level and motion, to estimate occupancy numbers, while an infrared camera is implemented to establish ground truth occupancy levels. Symmetrical uncertainty analysis is used for feature selection, and selected multi-sensory features are fused using a neuralnetwork model, with occupancy estimation accuracy reaching up to 84.59%. The proposed system offers promising opportunities for reliable occupancy sensing, capable of supporting demand driven HVAC operations.

Ekwevugbe, T.; Brown, N.; Pakka, V.

2013-01-01T23:59:59.000Z

199

Energy Renovations: Volume 14: HVAC - A Guide for Contractors to Share with Homeowners  

SciTech Connect

This report was prepared by PNNL for DOE's Building America program and is intended as a guide that energy performance contractors can share with homeowners to describe various energy-efficient options for heating, cooling, and ventilating existing homes. The report provides descriptions of many common and not-so-common HVAC systems, including their advantages and disadvantages, efficiency ranges and characteristics of high-performance models, typical costs, and climate considerations. The report also provides decision trees and tables of useful information for homeowners who are making decisions about adding, replacing, or upgrading existing HVAC equipment in their homes. Information regarding home energy performance assessments (audits) and combustion safety issues when replacing HVAC equipment are also provided.

Gilbride, Theresa L.; Baechler, Michael C.; Hefty, Marye G.; Hand, James R.; Love, Pat M.

2011-08-29T23:59:59.000Z

200

Simple Cosmological Model with Relativistic Gas  

E-Print Network (OSTI)

We construct simple and useful approximation for the relativistic gas of massive particles. The equation of state is given by an elementary function and admits analytic solution of the Friedmann equation, including more complex cases when the relativistic gas of massive particles is considered together with radiation or with dominating cosmological constant. The model of relativistic gas may be interesting for the description of primordial Universe, especially as a candidate for the role of a Dark Matter.

Guilherme de Berredo-Peixoto; Ilya L. Shapiro; Flavia Sobreira

2004-12-11T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Real-Time Measurement of Rates of Outdoor Airflow into HVAC Systems: A Field Study of Three Technologies  

E-Print Network (OSTI)

to determine flow resistance of HVAC ducts and fittings.W. 2003. Outdoor airflow into HVAC systems: an evaluation ofof outdoor airflow into HVAC systems. Lawrence Berkeley

Fisk, William J.; Sullivan, Douglas P.; Faulkner, David

2005-01-01T23:59:59.000Z

202

Modeling well performance in compartmentalized gas reservoirs  

E-Print Network (OSTI)

Predicting the performance of wells in compartmentalized reservoirs can be quite challenging to most conventional reservoir engineering tools. The purpose of this research is to develop a Compartmentalized Gas Depletion Model that applies not only to conventional consolidated reservoirs (with constant formation compressibility) but also to unconsolidated reservoirs (with variable formation compressibility) by including geomechanics, permeability deterioration and compartmentalization to estimate the OGIP and performance characteristics of each compartment in such reservoirs given production data. A geomechanics model was developed using available correlation in the industry to estimate variable pore volume compressibility, reservoir compaction and permeability reduction. The geomechanics calculations were combined with gas material balance equation and pseudo-steady state equation and the model was used to predict well performance. Simulated production data from a conventional gas Simulator was used for consolidated reservoir cases while synthetic data (generated by the model using known parameters) was used for unconsolidated reservoir cases. In both cases, the Compartmentalized Depletion Model was used to analyze data, and estimate the OGIP and Jg of each compartment in a compartmentalized gas reservoir and predict the subsequent reservoir performance. The analysis was done by history-matching gas rate with the model using an optimization technique. The model gave satisfactory results with both consolidated and unconsolidated reservoirs for single and multiple reservoir layers. It was demonstrated that for unconsolidated reservoirs, reduction in permeability and reservoir compaction could be very significant especially for unconsolidated gas reservoirs with large pay thickness and large depletion pressure.

Yusuf, Nurudeen

2007-12-01T23:59:59.000Z

203

Project Title Economic Modeling & Unconventional Gas Resource Appraisal Program Line Tough Gas  

E-Print Network (OSTI)

support to assess the economic viability of new tough gas plays (tight gas, shale gas, CBM). Project are illustrated using the US shale gas plays as case templates. Discounted cash flow models are applied1 Project Title Economic Modeling & Unconventional Gas Resource Appraisal Program Line Tough Gas

Santos, Juan

204

World Energy Projection System Plus Model Documentation: Natural Gas Model  

Reports and Publications (EIA)

This report documents the objectives, analytical approach and development of the World Energy Projection System Plus (WEPS+) Natural Gas Model. It also catalogues and describes critical assumptions, computational methodology, parameter estimation techniques, and model source code.

Brian Murphy

2011-09-29T23:59:59.000Z

205

Gas network model allows full reservoir coupling  

Science Conference Proceedings (OSTI)

The gas-network flow model (Gasnet) developed for and added to an existing Qatar General Petroleum Corp. (OGPC) in-house reservoir simulator, allows improved modeling of the interaction among the reservoir, wells, and pipeline networks. Gasnet is a three-phase model that is modified to handle gas-condensate systems. The numerical solution is based on a control volume scheme that uses the concept of cells and junctions, whereby pressure and phase densities are defined in cells, while phase flows are defined at junction links. The model features common numerical equations for the reservoir, the well, and the pipeline components and an efficient state-variable solution method in which all primary variables including phase flows are solved directly. Both steady-state and transient flow events can be simulated with the same tool. Three test cases show how the model runs. One case simulates flow redistribution in a simple two-branch gas network. The second simulates a horizontal gas well in a waterflooded gas reservoir. The third involves an export gas pipeline coupled to a producing reservoir.

Methnani, M.M. [Qatar General Petroleum Corp., Doha (Qatar)

1998-02-23T23:59:59.000Z

206

HVAC Efficiency Controls Could Mean Significant Savings | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Efficiency Controls Could Mean Significant Savings HVAC Efficiency Controls Could Mean Significant Savings HVAC Efficiency Controls Could Mean Significant Savings April 27, 2012 - 11:58am Addthis HVAC Efficiency Controls Could Mean Significant Savings April Saylor April Saylor Former Digital Outreach Strategist, Office of Public Affairs What does this mean for me? Commercial building owners could save an average 38% on their heating & cooling bills just by installing a few new controls onto their HVAC systems. According to a new report from Pacific Northwest National Lab, commercial building owners could save an average 38 percent on their heating and cooling bills just by installing a few new controls onto their HVAC systems. These findings mean significant potential savings for building owners who use commercial rooftop systems - but there's just one problem: the

207

Applications of HVAC System Utilizing Building Thermal Mass in Japan  

NLE Websites -- All DOE Office Websites (Extended Search)

Applications of HVAC System Utilizing Building Thermal Mass in Japan Applications of HVAC System Utilizing Building Thermal Mass in Japan Speaker(s): Katsuhiro Miura Date: January 27, 2012 - 10:00am Location: 90-3122 Seminar Host/Point of Contact: Michael Wetter Buildings have a large thermal capacity and it affects much on building thermal load for the HVAC system. The thermal mass can be utilized also to control the thermal load by storing thermal energy before HVAC operation. There are two ways to store thermal energy. One is by operating the HVAC system and the other is by natural ventilation, mainly at night. The latter could be combined with daily HVAC operation as a hybrid ventilation. Thermal mass storage is useful to decrease the hourly peak load and the daily thermal load and can be used for both cooling and heating purpose.

208

Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger  

NLE Websites -- All DOE Office Websites (Extended Search)

Radial Air Bearing Radial Air Bearing Heat Exchanger Research Project to someone by E-mail Share Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Facebook Tweet about Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Twitter Bookmark Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Google Bookmark Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Delicious Rank Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Digg Find More places to share Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE

209

HVAC BESTEST: A Procedure for Testing the Ability of Whole-Building Energy Simulation Programs to Model Space Conditioning Equipment: Preprint  

DOE Green Energy (OSTI)

Validation of Building Energy Simulation Programs consists of a combination of empirical validation, analytical verification, and comparative analysis techniques (Judkoff 1988). An analytical verification and comparative diagnostic procedure was developed to test the ability of whole-building simulation programs to model the performance of unitary space-cooling equipment that is typically modeled using manufacturer design data presented as empirically derived performance maps. Field trials of the method were conducted by researchers from nations participating in the International Energy Agency (IEA) Solar Heating and Cooling (SHC) Programme Task 22, using a number of detailed hourly simulation programs from Europe and the United States, including: CA-SIS, CLIM2000, PROMETHEUS, TRNSYS-TUD, and two versions of DOE-2.1E. Analytical solutions were also developed for the test cases.

Neymark, J,; Judkoff, R.; Knabe, G.; Le, H.-T.; Durig, M.; Glass, A.; Zweifel, G.

2001-07-03T23:59:59.000Z

210

BFRL: HVAC&R - Publications  

Science Conference Proceedings (OSTI)

... Air conditioning; Refrigerating system; Evaporator; Finned tube; Modeling; Optimization; R600a; R410A; Propane; R32; R134a; R22; Comparison. ...

211

The Agricultural Sector and Greenhouse Gas Mitigation Model (ASMGHG)  

E-Print Network (OSTI)

The Agricultural Sector and Greenhouse Gas Mitigation Model (ASMGHG) Uwe A. Schneider Bruce A. Mc Sector and Greenhouse Gas Mitigation Model (ASMGHG Taxes and Sequestration Subsidies...............................66 3.8.2.4 Special Greenhouse Gas

McCarl, Bruce A.

212

A systems approach to retrofitting residential HVAC systems  

E-Print Network (OSTI)

HVAC System. LBNL 53444. Wendt, R.L. , Ternes, M.P. , O’realized. Other guides (e.g. , Wendt et al. (1997)) are more

McWilliams, J.A.; Walker, I.S.

2004-01-01T23:59:59.000Z

213

Columbia Water & Light- HVAC and Lighting Efficiency Rebates  

Energy.gov (U.S. Department of Energy (DOE))

Columbia Water & Light (CWL) offers rebates to its commercial and industrial customers for the purchase of high efficiency HVAC installations and efficient lighting. Incentives for certain...

214

Algoritmi per la previsione del carico in applicazioni HVAC.  

E-Print Network (OSTI)

??Il lavoro si pone come obiettivo l’applicazione di metodi e algoritmi per la previsione del carico in sistemi HVAC (Heating, Ventilating and Air Conditioning). La… (more)

Simmini, Francesco

2010-01-01T23:59:59.000Z

215

Fault Detection and Diagnosis in Building HVAC Systems.  

E-Print Network (OSTI)

??Building HVAC systems account for more than 30% of annual energy consumption in United States. However, it has become apparent that only in a small… (more)

Najafi, Massieh

2010-01-01T23:59:59.000Z

216

New developments in noise control for HVAC systems.  

Science Conference Proceedings (OSTI)

The HVAC equipment industry is not known for rapid change. Although control systems have improved rapidly over the past few years

Timothy J. Foulkes

1996-01-01T23:59:59.000Z

217

The impact of filter loading on residential hvac performance.  

E-Print Network (OSTI)

??Buildings are the primary user of energy in the USA. Within homes, the heating, ventilation, and air condition (HVAC) system is the largest energy consumer.… (more)

Kruger, Abraham J.

2013-01-01T23:59:59.000Z

218

System Optimization - The Global Approach to HVAC Control  

E-Print Network (OSTI)

System Optimization is a new approach to HVAC control as implemented by Energy Management Control Systems. System Optimization is defined as electronic building control strategies which treat a building's HVAC components as a complete energy-efficient and coordinated system. Trends in the development of HVAC control strategies are briefly discussed. An example which differentiates between conventional and System Optimization approaches is used to illustrate this new approach. The example discusses aspects of cooling season operation for a typical HVAC system. The paper concludes with four basic principles of System Optimization which are essential for effective control of a building environment.

Thielman, D. E.

1984-01-01T23:59:59.000Z

219

Deposition of biological aerosols on HVAC heat exchangers  

E-Print Network (OSTI)

Methods to Maintain Heat Exchanger Coil Cleanliness. ASHRAEEngineering Foundation on Heat Exchanger Fouling, UnitedAerosols on HVAC Heat Exchangers Jeffrey Siegel and Iain

Siegel, Jeffrey; Walker, Iain

2001-01-01T23:59:59.000Z

220

Deposition of biological aerosols on HVAC heat exchangers  

E-Print Network (OSTI)

Methods to Maintain Heat Exchanger Coil Cleanliness. ASHRAEEngineering Foundation on Heat Exchanger Fouling, Unitedof HVAC Fin and Tube Heat Exchangers, To be published in the

Siegel, Jeffrey; Walker, Iain

2001-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

NREL Delivers In-Home HVAC Efficiency Testing Solutions (Fact...  

NLE Websites -- All DOE Office Websites (Extended Search)

Delivers In-Home HVAC Efficiency Testing Solutions Researchers at the National Renewable Energy Laboratory (NREL) have recently developed two simple in-home efficiency test methods...

222

Performance Evaluation of Dense Gas Dispersion Models  

Science Conference Proceedings (OSTI)

This paper summarizes the results of a study to evaluate the performance of seven dense gas dispersion models using data from three field experiments. Two models (DEGADIS and SLAB) are in the public domain and the other five (AIRTOX, CHARM, FOCUS,...

Jawad S. Touma; William M. Cox; Harold Thistle; James G. Zapert

1995-03-01T23:59:59.000Z

223

Uncertainties in Achieving Energy Savings from HVAC Maintenance Measures in the Field  

E-Print Network (OSTI)

Uncertainties in Achieving Energy Savings from HVAC Maintenance Measures in the Field Kristin Group, Davis, CA, USA 4 Southern California Edison, Irwindale, CA, USA ABSTRACT HVAC maintenance utilities across the nation to include HVAC maintenance measures in energy efficiency programs

California at Davis, University of

224

Analysis of a hybrid UFAD and radiant hydronic slab HVAC system  

E-Print Network (OSTI)

Air- Conditioning Engineers HVAC & R Research, vol. 50, Sep.and radiant hydronic slab HVAC system.   Paul RAFTERY a,* ,of a novel integrated HVAC system. This system combines an

Raftery, Paul; Lee, Kwang Ho; Webster, Thomas; Bauman, Fred

2011-01-01T23:59:59.000Z

225

Report on HVAC option selections for a relocatable classroom energy and indoor environmental quality field study  

E-Print Network (OSTI)

LBNL- 49026 Report on HVAC Option Selections for aTable 3. High performance HVAC system filter selectionDrop ("H 2 O) Appendix A – RC HVAC working drawings. Figure

2001-01-01T23:59:59.000Z

226

Combustion modeling in advanced gas turbine systems  

DOE Green Energy (OSTI)

Goal of DOE`s Advanced Turbine Systems program is to develop and commercialize ultra-high efficiency, environmentally superior, cost competitive gas turbine systems for base-load applications in utility, independent power producer, and industrial markets. Primary objective of the program here is to develop a comprehensive combustion model for advanced gas turbine combustion systems using natural gas (coal gasification or biomass fuels). The efforts included code evaluation (PCGC-3), coherent anti-Stokes Raman spectroscopy, laser Doppler anemometry, and laser-induced fluorescence.

Smoot, L.D.; Hedman, P.O.; Fletcher, T.H.; Brewster, B.S.; Kramer, S.K. [Brigham Young Univ., Provo, UT (United States). Advanced Combustion Engineering Research Center

1995-12-31T23:59:59.000Z

227

Modeling the motion of a hot, turbulent gas  

Science Conference Proceedings (OSTI)

Keywords: animation, convection, gas simulations, gaseous phenomena, physics-based modeling, smoke, steam, turbulent flow

Nick Foster; Dimitris Metaxas

1997-08-01T23:59:59.000Z

228

Computational Study on Thermal Properties of HVAC System with Building Structure Thermal Storage  

E-Print Network (OSTI)

Building structure thermal storage (BSTS) HVAC systems can store heat during nighttime thermal storage operation (nighttime operation hours) by using off-peak electricity and release it in the daytime air-conditioning operation (daytime operation hours) by utilizing a large amount of the thermal capacity of building structures such as beams, columns and floors composed of concrete. These BSTS systems have recently been considered as one method for leveling hourly electricity demands for HVAC on a day-to-day basis. Through a simulation using a model developed with experimental data, this paper describes how various factors for the design and operation of a BSTS quantitatively affect the charge/discharge performances of a HVAC system. As a result, the following was revealed: the thermal performance of the system is strongly influenced by the daily heat storage operation hours, supply air volume and supply air temperature during the nighttime operation hours, stored heat caused the total daytime cooling extraction to decrease by 11% to 58% and the daily total cooling extraction through nighttime to daytime to increase by 4% to 17% compared with the values of non- thermal storage HVAC system.

Sato, Y.; Sagara, N.; Ryu, Y.; Maehara, K.; Nagai, T.

2007-01-01T23:59:59.000Z

229

Gas  

Science Conference Proceedings (OSTI)

... Implements a gas based on the ideal gas law. It should be noted that this model of gases is niave (from many perspectives). ...

230

Lighting/HVAC interactions and their effects on annual and peak HVAC requirements in commercial buildings  

SciTech Connect

Lighting measures is one effective strategy for reducing energy use in commercial buildings. Reductions in lighting energy have secondary effects on cooling/heating energy consumption and peak HVAC requirements; in general, they increase the heating and decrease cooling requirements of a building. Net change in a building`s annual and peak energy requirements, however, is difficult to quantify and depends on building characteristics, operating conditions, climate. This paper characterizes impacts of lighting/HVAC interactions on annual and peak heating/cooling requirements of prototypical US commercial buildings through computer simulations using DOE-2.1E building energy analysis program. Ten building types of two vintages and nine climates are chosen to represent the US commercial building stock. For each combination, a prototypical building is simulated with two lighting power densities, and resultant changes in heating and cooling loads are recorded. Simple concepts of Lighting Coincidence Factors are used to describe the observed interactions between lighting and HVAC requirements. (Coincidence Factor (CF) is ratio of changes in HVAC loads to those in lighting loads, where load is either annual or peak load). The paper presents tables of lighting CF for major building types and climates. These parameters can be used for regional or national cost/benefit analyses of lighting- related policies and utility DSM programs. Using Annual CFs and typical efficiencies for heating and cooling systems, net changes in space conditioning energy use from a lighting measure can be calculated. Similarly, Demand CFs can be used to estimate the changes in HVAC sizing, which can then be converted to changes in capital outlay using standard-design curves; or they can be used to estimate coincident peak reductions for the analysis of the utility`s avoided costs. Results from use of these tables are meaningful only when they involve a significantly large number of buildings.

Sezgen, A.O.; Huang, Y.J.

1994-08-01T23:59:59.000Z

231

The Application of Ultraviolet Germicidal Technology in HVAC Systems  

E-Print Network (OSTI)

One of the most significant issues for today's HVAC (Heating, Ventilation, and Air Conditioning) engineer is Indoor Air Quality (IAQ). Many building owners, operators, and occupants complain of foul odors emanating from HVAC systems. The objectionable odor is the byproduct of the microbial growth (mold and fungus) that accumulates and develops on wet surfaces of HVAC units, causing foul odors to emanate from affected systems and degrading the IAQ and unit performance. This objectionable odor has been appropriately named the "Dirty Sock" syndrome. Less obvious to the building occupants, but of equal importance, are the physical effects the microbial organisms have on HVAC equipment. They restrict the airflow and limit the heat transfer capability, which increases the operating costs of the equipment. Fortunately, IAQ degradation, foul odor, and increased expenses can be eliminated with the installation of the ultraviolet 'C' band (W-C) lamps. The ultraviolet germicidal lamps are designed to kill odor causing mold and fungus that grow in wet evaporator sections of HVAC units. These lamps are installed inside HVAC systems and irradiate areas inhabited by the offending organisms, making it impossible for them to survive. The organisms disappear, the odors disappear, and most importantly, the IAQ complaints disappear. This guide will discuss the microbial growth and IAQ contaminant problems in the HVAC industry, the W-C lamp and other possible solutions, and the benefits of using the HVAC Duty W-C lamp.

Taylor, M. J.

2000-01-01T23:59:59.000Z

232

Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics  

E-Print Network (OSTI)

Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate the economic attractiveness of retrofitting HVAC industrial energy recovery equipment.

Graham, E. L.

1980-01-01T23:59:59.000Z

233

Theoretical Minimum Energy Use of a Building HVAC System  

E-Print Network (OSTI)

This paper investigates the theoretical minimum energy use required by the HVAC system in a particular code compliant office building. This limit might be viewed as the "Carnot Efficiency" for HVAC system. It assumes that all ventilation and air conditioning in the building are provided using the minimum energy value that does not violate physical law.

Tanskyi, O.

2011-01-01T23:59:59.000Z

234

HVAC & Building Management Control System Energy Efficiency Replacements  

SciTech Connect

The project objective was the replacement of an aging, un-repairable HVAC system which has grown inefficient and a huge energy consumer with low energy and efficient HVAC units, and installation of energy efficient building control technologies at City's YMCA Community Center.

Hernandez, Adriana

2012-09-21T23:59:59.000Z

235

Columbia Water and Light - HVAC and Lighting Efficiency Rebates |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Columbia Water and Light - HVAC and Lighting Efficiency Rebates Columbia Water and Light - HVAC and Lighting Efficiency Rebates Columbia Water and Light - HVAC and Lighting Efficiency Rebates < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Lighting: 50% of invoiced cost up to $22,500 Program Info State Missouri Program Type Utility Rebate Program Rebate Amount HVAC Replacements: $570 - $3,770 Lighting: $300/kW reduction or half of project cost Provider Columbia Water and Light Columbia Water and Light (CWL) offers rebates to its commercial and industrial customers for the purchase of high efficiency HVAC installations and efficient lighting. Incentives for certain measures are based upon the

236

Greenhouse Gas Training Program for Inventory and Mitigation Modeling |  

Open Energy Info (EERE)

Greenhouse Gas Training Program for Inventory and Mitigation Modeling Greenhouse Gas Training Program for Inventory and Mitigation Modeling Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Greenhouse Gas Training Program for Inventory and Mitigation Modeling Agency/Company /Organization: Future Perfect Sector: Climate Focus Area: GHG Inventory Development, Greenhouse Gas Topics: GHG inventory, Low emission development planning, -LEDS Resource Type: Case studies/examples, Training materials Website: www.gpstrategiesltd.com/divisions/future-perfect/ Country: South Korea Eastern Asia Language: English References: Greenhouse Gas Training Program for Inventory and Mitigation Modeling[1] Logo: Greenhouse Gas Training Program for Inventory and Mitigation Modeling Jointly sponsored by Greenhouse Gas Inventory & Research (GIR) Center of

237

Natural Gas Supply in Denmark -A Model of Natural Gas Transmission and the  

E-Print Network (OSTI)

Natural Gas Supply in Denmark - A Model of Natural Gas Transmission and the Liberalized Gas Market of the markets of natural gas and electricity and the existence of an abundance of de-centralized combined heat and power generators of which most are natural gas fired, leads to the natural assumption that the future

238

Interdisciplinary Innovation and Vision in the HVAC  

E-Print Network (OSTI)

High energy costs in buildings are forcing the building owners, developers, fund and facility managers to find alternate energy efficiency methods while improving the indoor air quality and thus the comfort level of the room occupants. High potentials for optimizing costs can be found in the HVAC systems when calculated over the total Life-Cycle-Cost (LCC) of a building incorporating planning through to facility management. This requires an accurate plan specifying an efficient technical operating method with optimized energy cost efficiency and comfort for the room occupants. In turn, the plan should be considered in any bidding process. Multisensory equipment is an integral part of the LCC concept and should not be underestimated in its impact on energy efficiency. The possibility of customizing the requirements of the room occupants should be included in each specification of a building/room automation system. The following case study will explain how modern sensory systems can be used for investment and energy savings in various HVAC system.

Hecker, T.

2008-01-01T23:59:59.000Z

239

Simulation of residential HVAC system performance  

SciTech Connect

In many parts of North America residential HVAC systems are installed outside conditioned space. This leads to significant energy losses and poor occupant comfort due to conduction and air leakage losses from the air distribution ducts. In addition, cooling equipment performance is sensitive to air flow and refrigerant charge that have been found to be far from manufacturers specifications in most systems. The simulation techniques discussed in this paper were developed in an effort to provide guidance on the savings potentials and comfort gains that can be achieved by improving ducts (sealing air leaks) and equipment (correct air-flow and refrigerant charge). The simulations include the complex air flow and thermal interactions between duct systems, their surroundings and the conditioned space. They also include cooling equipment response to air flow and refrigerant charge effects. Another key aspect of the simulations is that they are dynamic--which accounts for cyclic losses from the HVAC system and the effect of cycle length on energy and comfort performance.

Walker, I.S.; Siegel, J.A.; Degenetais, G.

2001-05-01T23:59:59.000Z

240

Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable-Speed-Drive Chillers  

E-Print Network (OSTI)

LBNL-58636 Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable Efficient Cleanrooms Efficient HVAC Water Systems: Variable-Speed-Drive Chillers Tengfang Xu Contents HVAC.................................................................................................................................... 6 #12;HVAC Water Systems Variable-Speed-Drive Chillers Summary Cleanroom energy benchmarking data

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Classroom HVAC: Improving ventilation and saving energy -- field study plan  

SciTech Connect

The primary goals of this research effort are to develop, evaluate, and demonstrate a very practical HVAC system for classrooms that consistently provides classrooms (CRs) with the quantity of ventilation in current minimum standards, while saving energy, and reducing HVAC-related noise levels. This research is motivated by the public benefits of energy efficiency, evidence that many CRs are under-ventilated, and public concerns about indoor environmental quality in CRs. This document provides a summary of the detailed plans developed for the field study that will take place in 2005 to evaluate the energy and IAQ performance of a new classroom HVAC technology. The field study will include measurements of HVAC energy use, ventilation rates, and IEQ conditions in 10 classrooms with the new HVAC technology and in six control classrooms with a standard HVAC system. Energy use and many IEQ parameters will be monitored continuously, while other IEQ measurements will be will be performed seasonally. Continuously monitored data will be remotely accessed via a LonWorks network. Instrument calibration plans that vary with the type of instrumentation used are established. Statistical tests will be employed to compare energy use and IEQ conditions with the new and standard HVAC systems. Strengths of this study plan include the collection of real time data for a full school year, the use of high quality instrumentation, the incorporation of many quality control measures, and the extensive collaborations with industry that limit costs to the sponsors.

Apte, Michael G.; Faulkner, David; Hodgson, Alfred T.; Sullivan, Douglas P.

2004-10-14T23:59:59.000Z

242

A Quasi-Dynamic HVAC and Building Simulation Methodology  

E-Print Network (OSTI)

This thesis introduces a quasi-dynamic building simulation methodology which complements existing building simulators by allowing transient models of HVAC (heating, ventilating and air-conditioning) systems to be created in an analogous way to their design and simulated in a computationally efficient manner. The methodology represents a system as interconnected, object-oriented sub-models known as components. Fluids and their local properties are modeled using discrete, incompressible objects known as packets. System wide pressure and flow rates are modeled similar to electrical circuit models. Transferring packets between components emulates fluid flow, while the system wide fluid circuit formed by the components' interconnections determines system wide pressures and flow rates. A tool named PAQS, after the PAacketized Quasi-dynamic Simulation methodology, was built to demonstrate the described methodology. Validation tests of PAQS found that its steady state energy use predictions differed less than 3% from a comparable steady state model. PAQS was also able to correctly model the transient behavior of a dynamic linear analytical system.

Davis, Clinton Paul

2012-05-01T23:59:59.000Z

243

Self-Correcting HVAC Controls Project Final Report  

SciTech Connect

This document represents the final project report for the Self-Correcting Heating, Ventilating and Air-Conditioning (HVAC) Controls Project jointly funded by Bonneville Power Administration (BPA) and the U.S. Department of Energy (DOE) Building Technologies Program (BTP). The project, initiated in October 2008, focused on exploratory initial development of self-correcting controls for selected HVAC components in air handlers. This report, along with the companion report documenting the algorithms developed, Self-Correcting HVAC Controls: Algorithms for Sensors and Dampers in Air-Handling Units (Fernandez et al. 2009), document the work performed and results of this project.

Fernandez, Nicholas; Brambley, Michael R.; Katipamula, Srinivas; Cho, Heejin; Goddard, James K.; Dinh, Liem H.

2010-01-04T23:59:59.000Z

244

COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM  

DOE Green Energy (OSTI)

In this paper, a hotel with hybrid geothermal heat pump system (HyGSHP) in the Pensacola is selected and simulated by the transient simulation software package TRNSYS [1]. To verify the simulation results, the validations are conducted by using the monthly average entering water temperature, monthly facility consumption data, and etc. And three types of HVAC systems are compared based on the same building model and HVAC system capacity. The results are presented to show the advantages and disadvantages of HyGSHP compared with the other two systems in terms of energy consumptions, life cycle cost analysis.

Jiang Zhu; Yong X. Tao

2011-11-01T23:59:59.000Z

245

Unusual HVAC challenges require innovative solutions  

SciTech Connect

There were many reasons behind Motorola`s decision to build the first 225,000 sq ft of a planned one million sq ft manufacturing facility in Chihuahua, Mexico. Among these were the availability of skilled labor in the area, lower construction costs, some export tax advantages, and the close proximity to the US border. The new facility is made up of a variety of functional areas that together create an impressively efficient plant. Phase 1 construction included a large manufacturing floor, shipping and receiving areas, a bulk storage facility, and a large office area with a view of the factory floor. The structure also houses a retail store where Motorola consumer products are sold, a conference and banquet center, a commercial kitchen, and dining facilities for 750. The design cooling load is 750 tons; the heating load is 4.5 million Btuh. The paper discusses the challenging location, the HVAC system, and the future expansion planned.

Jardine, G.M.; Gwin, O.D. [Heery International, Inc., Atlanta, GA (United States)

1998-02-01T23:59:59.000Z

246

SURFACE INDUSTRIAL HVAC SYSTEM DESCRIPTION DOCUMENT  

SciTech Connect

The purpose of this system description document (SDD) is to establish requirements that drive the design of the surface industrial heating, ventilation, and air-conditioning (HVAC) system and its bases to allow the design effort to proceed to license application. This SDD will be revised at strategic points as the design matures. This SDD identifies the requirements and describes the system design, as it currently exists, with emphasis on attributes of the design provided to meet the requirements. This SDD is an engineering tool for design control; accordingly, the primary audience and users are design engineers. This SDD is part of an iterative design process. It leads the design process with regard to the flowdown of upper tier requirements onto the system. Knowledge of these requirements is essential to performing the design process. The SDD follows the design with regard to the description of the system. The description that provided in this SDD reflects the current results of the design process.

M.M. Ansari

2005-04-05T23:59:59.000Z

247

HVAC system analysis: energy audit review  

SciTech Connect

Although most energy audits do not investigate HVAC systems in as much detail as would most design consultants, audit data can be most informative. For certain types of buildings, air-conditioning energy usage can be estimated by its absence from energy bills during winter months, and heating energy usage can be estimated by its absence from energy bills during the summer months. Cooling and heating energy usage can be even more accurately broken down when a fossil fuel is used for heating while electrical energy is used for cooling. It is easy to establish fairly accurate energy consumption estimates for lighting, fan motors, and pumps; this can be done by verifying their loads and multiplying them by known operating hours. The numerous notes contained in some energy audits may also provide ideas for retrofitting energy-consuming areas.

Harmon, K.S.

1983-01-01T23:59:59.000Z

248

Settlement Prediction, Gas Modeling and Slope Stability Analysis  

E-Print Network (OSTI)

Settlement Prediction, Gas Modeling and Slope Stability Analysis in Coll Cardús Landfill Li Yu using mechanical models Simulation of gas generation, transport and extraction in MSW landfill 1 models Simulation of gas generation, transport and extraction in MSW landfill 1) Analytical solution

Politècnica de Catalunya, Universitat

249

Co-simulation for performance prediction of integrated building and HVAC systems - An analysis of solution characteristics using a two-body system  

E-Print Network (OSTI)

of innovative integrated HVAC systems in buildings, infor building envelope and HVAC systems simu- lation - WillIntegrated simulation for HVAC performance prediction: State

Trcka, Marija

2010-01-01T23:59:59.000Z

250

Connexus Energy - Residential Efficient HVAC Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Connexus Energy - Residential Efficient HVAC Rebate Program Connexus Energy - Residential Efficient HVAC Rebate Program Connexus Energy - Residential Efficient HVAC Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Program Info Expiration Date 12/31/2013 State Minnesota Program Type Utility Rebate Program Rebate Amount Air Source Heat Pumps: $480 - $630 Ductless Heat Pump: $150 Geothermal Heat Pump: $200/ton Provider Connexus Energy Connexus Energy offers rebates for residential customers to improve the energy efficiency of homes. Rebates are available for air source heat pumps, ductless heat pumps and ground-source heat pumps. Equipment must meet all efficiency standards listed on the web site, and must be installed by a certified HVAC contractor. Contact Connexus Energy for other program

251

Strategy Guideline: Transitioning HVAC Companies to Whole House Performance Contractors  

Science Conference Proceedings (OSTI)

This report describes the findings from research IBACOS conducted related to heating, ventilation, and air conditioning (HVAC) companies who have made the decision to transition to whole house performance contracting (WHPC).

Burdick, A.

2012-05-01T23:59:59.000Z

252

Direct Digital Control for Building HVAC Systems, 2nd edition  

Science Conference Proceedings (OSTI)

From the Publisher:Direct Digital Control for Building HVAC Systems, Second Edition, is thoroughly updated and expanded to include complete coverage of the architecture of modern digital control systems, distributed intelligence networked systems, communication ...

Michael J. L. Coffin

1998-06-01T23:59:59.000Z

253

Review of Residential Low-Load HVAC Systems  

SciTech Connect

In support of the U.S. Department of Energy’s (DOE’s) Building America Program, Pacific Northwest National Laboratory (PNNL) conducted an investigation to inventory commercially available HVAC technologies that are being installed in low-load homes. The first step in this investigation was to conduct a review of published literature to identify low-load HVAC technologies available in the United States and abroad, and document the findings of existing case studies that have evaluated the performance of the identified technologies. This report presents the findings of the literature review, identifies gaps in the literature or technical understanding that must be addressed before low-load HVAC technologies can be fully evaluated, and introduces PNNL’s planned research and analysis for this project to address identified gaps and potential future work on residential low-load HVAC systems.

Brown, Scott A.; Thornton, Brian; Widder, Sarah H.

2013-09-01T23:59:59.000Z

254

DOE Convening Report on Certification of Commercial HVAC and...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Convening Report on Certification of Commercial HVAC and CRE Products, October 2, 2012 1 U.S. DEPARTMENT OF ENERGY CONVENING REPORT ON THE FEASIBILITY OF A NEGOTIATED RULEMAKING TO...

255

Software-Based Building Airflow Analysis Tool for Enabling HVAC...  

NLE Websites -- All DOE Office Websites (Extended Search)

Software-Based Building Airflow Analysis Tool for Enabling HVAC Energy Use Savings in Commercial Buildings Speaker(s): Don Wroblewski Date: March 8, 2013 - 12:00pm Location:...

256

Columbia Water and Light- Residential HVAC Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Columbia Water and Light (CWL) provides an HVAC incentive for residential customers that are replacing an older heating and cooling system. Customers should submit the mechanical permit from a...

257

Sound quality descriptors for HVAC equipment from ARI Standards  

Science Conference Proceedings (OSTI)

The Air Conditioning and Refrigeration Institute (ARI) has several standards that provide methods to evaluate the sound quality of heating ventilating and air?conditioning (HVAC) equipment. These include Standard 270 Sound rating of outdoor unitary equipment

2003-01-01T23:59:59.000Z

258

Commissioning and Performance Diagnostics for HVAC Control Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Commissioning and Performance Diagnostics for HVAC Control Systems Speaker(s): Ashish Singhal Date: December 20, 2006 - 12:00pm Location: 90-3122 Seminar HostPoint of Contact:...

259

Adaptive Control and Fault Detection of HVAC Equipment in Commercial...  

NLE Websites -- All DOE Office Websites (Extended Search)

Adaptive Control and Fault Detection of HVAC Equipment in Commercial Buildings Speaker(s): John Seem Date: February 27, 2002 - 12:00pm Location: Bldg. 90 Seminar HostPoint of...

260

Optimized HVAC Management Service to Enhance Demand Response  

NLE Websites -- All DOE Office Websites (Extended Search)

Optimized HVAC Management Service to Enhance Demand Response Speaker(s): John Steinberg Date: August 18, 2011 - 12:00pm Location: 90-4133 Seminar HostPoint of Contact: Janie Page...

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Applications of HVAC System Utilizing Building Thermal Mass in...  

NLE Websites -- All DOE Office Websites (Extended Search)

Applications of HVAC System Utilizing Building Thermal Mass in Japan Speaker(s): Katsuhiro Miura Date: January 27, 2012 - 10:00am Location: 90-3122 Seminar HostPoint of Contact:...

262

Neural network based optimal control of HVAC&R systems.  

E-Print Network (OSTI)

??Heating, Ventilation, Air-Conditioning and Refrigeration (HVAC&R) systems have wide applications in providing a desired indoor environment for different types of buildings. It is well acknowledged… (more)

Ning, Min

2008-01-01T23:59:59.000Z

263

LBL-34045 UC-1600 Residential HVAC Data, Assumptions and Methodology  

NLE Websites -- All DOE Office Websites (Extended Search)

5 UC-1600 Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1 Francis X. Johnson, Richard E. Brown, James W. Hanford, Alan H. Sanstad and...

264

Ameren Illinois (Electric)- Custom, HVAC, and Motor Business Efficiency Incentives  

Energy.gov (U.S. Department of Energy (DOE))

Prescriptive rebates are available for many HVAC and motor efficiency improvements. Pre-approval is required for all rebates. The programs are available only to non-residential customers that...

265

Comparisons of HVAC Simulations between EnergyPlus and DOE-2.2 for Data Centers  

SciTech Connect

This paper compares HVAC simulations between EnergyPlus and DOE-2.2 for data centers. The HVAC systems studied in the paper are packaged direct expansion air-cooled single zone systems with and without air economizer. Four climate zones are chosen for the study - San Francisco, Miami, Chicago, and Phoenix. EnergyPlus version 2.1 and DOE-2.2 version 45 are used in the annual energy simulations. The annual cooling electric consumption calculated by EnergyPlus and DOE-2.2 are reasonablely matched within a range of -0.4percent to 8.6percent. The paper also discusses sources of differences beween EnergyPlus and DOE-2.2 runs including cooling coil algorithm, performance curves, and important energy model inputs.

Hong, Tianzhen; Sartor, Dale; Mathew, Paul; Yazdanian, Mehry

2008-08-13T23:59:59.000Z

266

gas | OpenEI  

Open Energy Info (EERE)

gas gas Dataset Summary Description The following data-set is for a benchmark residential home for all TMY3 locations across all utilities in the US. The data is indexed by utility service provider which is described by its "unique" EIA ID ( Source National Renewable Energy Laboratory Date Released April 05th, 2012 (2 years ago) Date Updated April 06th, 2012 (2 years ago) Keywords AC apartment CFL coffeemaker Computer cooling cost demand Dishwasher Dryer Furnace gas HVAC Incandescent Laptop load Microwave model NREL Residential television tmy3 URDB Data text/csv icon Residential Cost Data for Common Household Items (csv, 14.5 MiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually Time Period License License Open Data Commons Public Domain Dedication and Licence (PDDL)

267

General Methodology Combining Engineering Optimization of Primary HVAC & R Plants with Decision Analysis Methods--Part I: Deterministic Analysis  

SciTech Connect

This paper is the first of a two-part sequence that proposes a general methodology for dynamic scheduling and optimal control of complex primary HVAC&R plants, which combines engineering analyses within a practical decision analysis framework by modeling risk attitudes of the operator. The paper was based on work done prior to employment by Battelle.

Jiang, Wei; Reddy, T. A.

2007-01-31T23:59:59.000Z

268

Gas transport model for chemical vapor infiltration  

Science Conference Proceedings (OSTI)

A node-bond percolation model is presented for the gas permeability and pore surface area of the coarse porosity in woven fiber structures during densification by chemical vapor infiltration (CVI). Model parameters include the number of nodes per unit volume and their spatial distribution, and the node and bond radii and their variability. These parameters relate directly to structural features of the weave. Some uncertainty exists in the proper partition of the porosity between ``node`` and ``bond`` and between intra-tow and inter-tow, although the total is constrained by the known fiber loading in the structure. Applied to cloth layup preforms the model gives good agreement with the limited number of available measurements.

Starr, T.L. [School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0245 (United States)

1995-09-01T23:59:59.000Z

269

SPINTHIR: An ignition model for gas turbines  

E-Print Network (OSTI)

(for both laminar and turbulent flames) and some of the findings are reviewed in Ref. [1] and, for sprays in particular, in Ref. [2]. A physics-based model with low computational cost was presented in Ref. [3] that aimed at estimating the growth of a... . is a constant taken equal to 2.0 [9]. Knowledge of ?~ ?C p? enables the calculation of and in turn of . The computation of the laminar flame speed as a function of the local mixture fraction for a gas flame is trivial, while in a spray is more...

Neophytou, A; Mastorakos, E

2012-08-28T23:59:59.000Z

270

Experimental Study of Main Gas Ingestion and Purge Gas Egress Flow in Model Gas Turbine Stages.  

E-Print Network (OSTI)

??Efficient performance of gas turbines depends, among several parameters, on the mainstream gas entry temperature. At the same time, transport of this high temperature gas… (more)

Balasubramanian, Jagdish Harihara

2010-01-01T23:59:59.000Z

271

Atomistic modeling of gas adsorption in nanocarbons  

Science Conference Proceedings (OSTI)

Carbon nanostructures are currently under investigation as possible ideal media for gas storage and mesoporous materials for gas sensors. The recent scientific literature concerning gas adsorption in nanocarbons, however, is affected by a significant ...

G. Zollo, F. Gala

2012-01-01T23:59:59.000Z

272

Multiscale Modelling of Single Crystal Superalloys for Gas Turbine Blades  

E-Print Network (OSTI)

Multiscale Modelling of Single Crystal Superalloys for Gas Turbine Blades PROEFSCHRIFT ter Multiscale Modelling of Single Crystal Superalloys for Gas Turbine Blades / by Tiedo Tinga. ­ Eindhoven accumulation 120 5.5 Application 121 5.6 Summary and conclusions 128 6. Application to gas turbine parts 131 6

273

Multivariable model predictive control for a gas turbine power plant  

Science Conference Proceedings (OSTI)

In this brief, constrained multi variable model predictive control (MPC) strategy is investigated for a GE9001E gas turbine power plant. So the rotor speed and exhaust gas temperature are controlled manipulating the fuel command and compressor inlet ... Keywords: ARX, gas turbine, identification, modeling, multivariable control, power plant, predictive control

Hadi Ghorbani; Ali Ghaffari; Mehdi Rahnama

2008-05-01T23:59:59.000Z

274

Evaluating the income and employment impacts of gas cooling technologies  

SciTech Connect

The purpose of this study is to estimate the potential employment and income benefits of the emerging market for gas cooling products. The emphasis here is on exports because that is the major opportunity for the U.S. heating, ventilating, and air-conditioning (HVAC) industry. But domestic markets are also important and considered here because without a significant domestic market, it is unlikely that the plant investments, jobs, and income associated with gas cooling exports would be retained within the United States. The prospects for significant gas cooling exports appear promising for a variety of reasons. There is an expanding need for cooling in the developing world, natural gas is widely available, electric infrastructures are over-stressed in many areas, and the cost of building new gas infrastructure is modest compared to the cost of new electric infrastructure. Global gas cooling competition is currently limited, with Japanese and U.S. companies, and their foreign business partners, the only product sources. U.S. manufacturers of HVAC products are well positioned to compete globally, and are already one of the faster growing goods-exporting sectors of the U.S. economy. Net HVAC exports grew by over 800 percent from 1987 to 1992 and currently exceed $2.6 billion annually (ARI 1994). Net gas cooling job and income creation are estimated using an economic input-output model to compare a reference case to a gas cooling scenario. The reference case reflects current policies, practices, and trends with respect to conventional electric cooling technologies. The gas cooling scenario examines the impact of accelerated use of natural gas cooling technologies here and abroad.

Hughes, P.J. [Oak Ridge National Lab., TN (United States); Laitner, S.

1995-03-01T23:59:59.000Z

275

Rock-physics Models for Gas-hydrate Systems Associated  

E-Print Network (OSTI)

at Austin, Austin, Texas, U.S.A. ABSTRACT R ock-physics models are presented describing gas-hydrate systems. Knapp, and R. Boswell, eds., Natural gas hydrates--Energy resource potential and associated geologic

Texas at Austin, University of

276

Evaluation of commercially available techniques and development of simplified methods for measuring grille airflows in HVAC systems  

E-Print Network (OSTI)

Walker. 2002. “Residential HVAC and Distribution researchMeasuring Grille Airflows in HVAC Systems I.S. Walker, C.P.Measuring Grille Airflows in HVAC Systems I.S. Walker, C.P.

Walker, Iain S.; Wray, Craig P.; Guillot, Cyril; Masson, S.

2003-01-01T23:59:59.000Z

277

Using measured equipment load profiles to "right-size" HVAC systems and reduce energy use in laboratory buildings (Pt. 2)  

E-Print Network (OSTI)

load profiles to “right-size” HVAC systems and reduce energyGeorgia. ASHRAE [1999]. HVAC Applications Handbook 1999.Inefficiency of a Common Lab HVAC System,” presented at the

Mathew, Paul; Greenberg, Steve; Frenze, David; Morehead, Michael; Sartor, Dale; Starr, William

2008-01-01T23:59:59.000Z

278

Validation of a Building Simulation Tool Using Field Data for Three Identical Configuration Full-Serve Restaurants Using Different HVAC Systems  

E-Print Network (OSTI)

A new building application for a pre-existing HVAC software tool which calculates the benefits of desiccant-assisted HVAC equipment versus the performance of a standard vapor-compression system is used to model the monitored results, see Yborra and Spears (2000), for three full-service restaurants. A standard vapor-compression system, an enthalpy assisted vapor-compression system, and a desiccant-assisted vapor-compression system are compared. The vapor-compression portion of each system is comprised of three rooftop units, specifications for each may be found in Yborra and Spears, "Field- Evaluation of Alternative HVAC Strategies to Meet Ventilation, Comfort, and Humidity Control Criteria at Three Full-Serve Restaurants". The software tool uses DOE 2.1E as a calculation engine which runs in the background. Previously, the software tool could model two different hotel configurations, a quickserve restaurant, a supermarket, a retail store, an ice arena, a school, a movie theater, a nursing home and a hospital. With the larger eating area, the full-serve restaurant had the capacity for sensible or enthalpy heat recovery from the exhausted air in the sit-down area. Quick-Serve Restaurants (QSR's) were precluded from these energy saving devices as the exhausted air was heavily laden with grease. Still, even with the kitchen exhausts facing away from the rooftop unit (RTU) intakes, the enthalpy wheels showed noticeable loading from grease. As the field monitoring was performed near Philadelphia, PA, National Renewable Energy Laboratory (NREL) hour-by-hour bin TMY2 meteorological data was used for Philadelphia to model the annual outdoor conditions experienced by each site. Output was provided in the form of humidity bins, monthly energy usage and cost, as well as total annual gas and electric costs. As the fill-serve restaurants were located on the North-Eastem region of the United States, patron comfort was of greater importance to management than annual energy cost savings. Once the model results were determined to properly reflect those of the case studies, the different building equipment types were "moved" around the United States by choosing different bin weather data sets corresponding to Chicago, IL, Atlanta, GA, and Houston, TX. While the default energy rates available in the program are 4 years old, the economic results provide a sound cost comparison.

Brillhart, P. L.; Worek, W. M.

2000-01-01T23:59:59.000Z

279

Model Documentation Report: International Natural Gas Model 2011  

U.S. Energy Information Administration (EIA)

gas-to-liquid (GTL) plants, ... • Natural gas production for five resource categories, ... while LNG contracts may constrain trade in

280

An evaluation of three commercially available technologies for real-time measurement of rates of outdoor airflow into HVAC systems  

E-Print Network (OSTI)

RATES OF OUTDOOR AIRFLOW INTO HVAC SYSTEMS William J. Fisk,determine flow resistance of hvac ducts and fittings. A S H

Fisk, William J.; Faulkner, David; Sullivan, Douglas P.

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Evaluation of the gas production economics of the gas hydrate cyclic thermal injection model  

SciTech Connect

The objective of the work performed under this directive is to assess whether gas hydrates could potentially be technically and economically recoverable. The technical potential and economics of recovering gas from a representative hydrate reservoir will be established using the cyclic thermal injection model, HYDMOD, appropriately modified for this effort, integrated with economics model for gas production on the North Slope of Alaska, and in the deep offshore Atlantic. The results from this effort are presented in this document. In Section 1, the engineering cost and financial analysis model used in performing the economic analysis of gas production from hydrates -- the Hydrates Gas Economics Model (HGEM) -- is described. Section 2 contains a users guide for HGEM. In Section 3, a preliminary economic assessment of the gas production economics of the gas hydrate cyclic thermal injection model is presented. Section 4 contains a summary critique of existing hydrate gas recovery models. Finally, Section 5 summarizes the model modification made to HYDMOD, the cyclic thermal injection model for hydrate gas recovery, in order to perform this analysis.

Kuuskraa, V.A.; Hammersheimb, E.; Sawyer, W.

1985-05-01T23:59:59.000Z

282

Forecasting Natural Gas Prices Using Time Series Models .  

E-Print Network (OSTI)

??The objective of this thesis is to estimate the natural gas component of the All Urban Consumer Price Index (CP-U) using time series forecasting models.… (more)

Berg, Andrew

2006-01-01T23:59:59.000Z

283

Issue #7: What are the Best HVAC Solutions for Low-Load, High...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7: What are the Best HVAC Solutions for Low-Load, High Performance Homes? Issue 7: What are the Best HVAC Solutions for Low-Load, High Performance Homes? What components and...

284

WEATHER SEQUENCES FOR PREDICTING HVAC SYSTEM BEHAVIOUR IN RESIDENTIAL UNITS LOCATED IN TROPICAL CLIMATES.  

E-Print Network (OSTI)

WEATHER SEQUENCES FOR PREDICTING HVAC SYSTEM BEHAVIOUR IN RESIDENTIAL UNITS LOCATED IN TROPICAL on the energy needs of HVAC system. We'll apply the method on the tropical Reunion Island. The methodological

Paris-Sud XI, Université de

285

Fight Fall Allergies and Save Energy by Checking Your HVAC System...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fight Fall Allergies and Save Energy by Checking Your HVAC System Fight Fall Allergies and Save Energy by Checking Your HVAC System October 15, 2012 - 3:19pm Addthis Change your...

286

Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Critical Question 4: What are the Best Off-the-Shelf HVAC Solutions for Low-Load, High-Performance Homes and Apartments? Critical Question 4: What are the Best Off-the-Shelf HVAC...

287

Commissioning and Performance Diagnostics for HVAC Control Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Commissioning and Performance Diagnostics for HVAC Control Systems Commissioning and Performance Diagnostics for HVAC Control Systems Speaker(s): Ashish Singhal Date: December 20, 2006 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Philip Haves The presentation will focus on practical aspects of commissioning control loops in commercial HVAC systems and evaluating their routine performance. Simple and theoretically sound methods for diagnosing control performance will be presented that detect serious performance issues associated with control loops in modern buildings. The discussion will center on a new control loop commissioning tool that helps field personnel to quickly test, tune and troubleshoot control loops. In addition to the active tests for commissioning control loops, a suite of diagnostic algorithms are used in a

288

Optimized HVAC Management Service to Enhance Demand Response  

NLE Websites -- All DOE Office Websites (Extended Search)

Optimized HVAC Management Service to Enhance Demand Response Optimized HVAC Management Service to Enhance Demand Response Speaker(s): John Steinberg Date: August 18, 2011 - 12:00pm Location: 90-4133 Seminar Host/Point of Contact: Janie Page Many utilities are investing vast sums deploying smart meters to customers, some of whom remain stubbornly opposed to those deployments, in large part because they remain unmoved by the claimed benefits. EcoFactor has developed a thermostat management service that delivers (and quantifies) significant energy savings for consumers and a number of additional benefits to other players in the energy value chain. It does so without relying on consumers to modify behavior, study energy information displays, or even pay attention to their energy use. EcoFactor also significantly boosts DR yield while it increases occupant comfort. It can identify HVAC

289

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives < Back Eligibility Commercial Industrial Multi-Family Residential Nonprofit Savings Category Other Heating & Cooling Commercial Heating & Cooling Cooling Home Weatherization Construction Commercial Weatherization Design & Remodeling Manufacturing Sealing Your Home Ventilation Heat Pumps Heating Appliances & Electronics Commercial Lighting Lighting Water Heating Maximum Rebate $600,000/year/facility. Incentives $1-$200,000: paid at 100% Incentives $200,000-$600,000: paid at 50% Custom: 50% of incremental cost Retro-Commissioning: $200,000/year/facility; $100,000/project Leak Survey: $10,000

290

Active noise control: A tutorial for HVAC designers  

Science Conference Proceedings (OSTI)

This article will identify the capabilities and limitations of ANC in its application to HVAC noise control. ANC can be used in ducted HVAC systems to cancel ductborne, low-frequency fan noise by injecting sound waves of equal amplitude and opposite phase into an air duct, as close as possible to the source of the unwanted noise. Destructive interference of the fan noise and injected noise results in sound cancellation. The noise problems that it solves are typically described as rumble, roar or throb, all of which are difficult to address using traditional noise control methods. This article will also contrast the use of active against passive noise control techniques. The main differences between the two noise control measures are acoustic performance, energy consumption, and design flexibility. The article will first present the fundamentals and basic physics of ANC. The application to real HVAC systems will follow.

Gelin, L.J.

1997-08-01T23:59:59.000Z

291

What are the Best HVAC Solutions for Low-Load, High Performance...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

What are the Best HVAC Solutions for Low Load, High Performance Homes? www.BuildingScience.com buildingscience.com...

292

GASCAP: Wellhead Gas Productive Capacity Model documentation, June 1993  

SciTech Connect

The Wellhead Gas Productive Capacity Model (GASCAP) has been developed by EIA to provide a historical analysis of the monthly productive capacity of natural gas at the wellhead and a projection of monthly capacity for 2 years into the future. The impact of drilling, oil and gas price assumptions, and demand on gas productive capacity are examined. Both gas-well gas and oil-well gas are included. Oil-well gas productive capacity is estimated separately and then combined with the gas-well gas productive capacity. This documentation report provides a general overview of the GASCAP Model, describes the underlying data base, provides technical descriptions of the component models, diagrams the system and subsystem flow, describes the equations, and provides definitions and sources of all variables used in the system. This documentation report is provided to enable users of EIA projections generated by GASCAP to understand the underlying procedures used and to replicate the models and solutions. This report should be of particular interest to those in the Congress, Federal and State agencies, industry, and the academic community, who are concerned with the future availability of natural gas.

Not Available

1993-07-01T23:59:59.000Z

293

RF propagation in an HVAC duct system: impulse response characteristics of the channel  

E-Print Network (OSTI)

RF propagation in an HVAC duct system: impulse response characteristics of the channel Pavel V, the heating, ventilation, and air conditioning (HVAC) duct system in buildings is a complex network of hollow at RF and microwave frequencies of com- mon interest. HVAC ducts can be used as a wireless communication

Stancil, Daniel D.

294

Fouling of HVAC Fin and Tube Heat Exchangers Jeffrey Siegel and Van P. Carey  

E-Print Network (OSTI)

LBNL-47668 Fouling of HVAC Fin and Tube Heat Exchangers Jeffrey Siegel and Van P. Carey CIEE ENDORSEMENT OF OR AGREEMENT WITH THESE FINDINGS, NOR THAT OF ANY CIEE SPONSOR. #12;FOULING OF HVAC in residential, commercial and industrial HVAC applications. Invariably, indoor and outdoor air contaminants foul

295

Department of Energy and Mineral Engineering Spring 2013 Solar Innovations -HVAC and Waste Stream Analysis  

E-Print Network (OSTI)

PENNSTATE Department of Energy and Mineral Engineering Spring 2013 Solar Innovations - HVAC and Waste Stream Analysis Overview There are two problems that were voiced by Solar Innovations, HVAC system design and recycling stream improvement. The HVAC system was not providing even conditioning of office

Demirel, Melik C.

296

Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond  

E-Print Network (OSTI)

Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond Lawrence Berkeley of the commissioning of HVAC systems. The approach is based on software that generates a sequence of test signals for new and retrofit projects. Introduction The performance of many HVAC systems is limited more by poor

Diamond, Richard

297

Multi-carrier Signal Transmission through HVAC Ducts: Experimental Results for Channel Capacity  

E-Print Network (OSTI)

Multi-carrier Signal Transmission through HVAC Ducts: Experimental Results for Channel Capacity, for the first time, experimental results on channel capacity of heating, ventilation, and air-conditioning (HVAC through a building HVAC duct system demonstrate the ability to transmit with a spectral efficiency of 3

Stancil, Daniel D.

298

VOLUME 11, NUMBER 2 HVAC&R RESEARCH APRIL 2005 An Optimization-Based Approach for  

E-Print Network (OSTI)

VOLUME 11, NUMBER 2 HVAC&R RESEARCH APRIL 2005 215 An Optimization-Based Approach for Facility formulation and the correspond- ing solution methodology for HVAC systems. The problem is to minimize the energy and demand costs through control of HVAC units while satisfying human comfort, system dynamics

Luh, Peter

299

Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture  

E-Print Network (OSTI)

Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture Ariton E. Xhafa, Paisarn-- In this paper, we present an innovative solution to the handover problem in multi-story buildings using HVAC of the indoor wireless networks that use the heating, ventilation, and air conditioning (HVAC) ducts

Stancil, Daniel D.

300

Conventional Facilities Chapter 6: HVAC Systems 6-1 NSLS-II Preliminary Design Report  

E-Print Network (OSTI)

Conventional Facilities Chapter 6: HVAC Systems 6-1 NSLS-II Preliminary Design Report 6 MECHANICAL ­ HVAC SYSTEMS 6.1 Design Criteria 6.1.1 Codes and Standards The latest edition of the codes, standards have adequate capacity and head, no chilled water pumps #12;Conventional Facilities Chapter 6: HVAC

Ohta, Shigemi

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Comparison of dust from HVAC filters, indoor surfaces, and indoor air Federico Noris*  

E-Print Network (OSTI)

Comparison of dust from HVAC filters, indoor surfaces, and indoor air Federico Noris* , Kerry A and Environmental Engineering * Corresponding email: Fedenoris@mail.utexas.edu SUMMARY HVAC filters are long heavy metal (Pb, Cd and As) concentrations. HVAC filter microbial concentrations appear to be consistent

Siegel, Jeffrey

302

VOLUME 16, NUMBER 3 HVAC&R RESEARCH MAY 2010 The Effects of Filtration on  

E-Print Network (OSTI)

VOLUME 16, NUMBER 3 HVAC&R RESEARCH MAY 2010 273 The Effects of Filtration on Pressure Drop and Energy Consumption in Residential HVAC Systems (RP-1299) Brent Stephens Atila Novoselac, PhD Jeffrey A of high-efficiency HVAC filters is a common strategy to control exposure to airborne particulate matter

Siegel, Jeffrey

303

Theoretical Estimates of HVAC Duct Channel Capacity for High-Speed Internet Access  

E-Print Network (OSTI)

Theoretical Estimates of HVAC Duct Channel Capacity for High-Speed Internet Access Ariton E. Xhafa-conditioning (HVAC) ducts based on multi-carrier transmission that uses M-QAM mod- ulation and measured channel- flections in HVAC ducts). Our work also shows that data rates in excess of 300 Mbps are possible over

Stancil, Daniel D.

304

Comparison of HVAC filter test methods for particle removal efficiency Brent Stephens1,*  

E-Print Network (OSTI)

Comparison of HVAC filter test methods for particle removal efficiency Brent Stephens1,* , Jeffrey Introduction The use of HVAC filters in buildings is one strategy to reduce occupant exposure to particulate matter. However, HVAC filters are typically tested only in laboratory settings and little is known about

Siegel, Jeffrey

305

Co-simulation for performance prediction of integrated building and HVAC systems -An analysis of solution  

E-Print Network (OSTI)

Co-simulation for performance prediction of integrated building and HVAC systems - An analysis performance simulation of buildings and heating, ventilation and air- conditioning (HVAC) systems can help, heating, ventilation and air-conditioning (HVAC) systems are responsible for 10%-60% of the total building

306

An Experimental Evaluation of HVAC-Grade Carbon-Dioxide Sensors: Part 2, Performance Test Results  

Science Conference Proceedings (OSTI)

This is the second paper in a four-part series reporting on the test and evaluation of typical carbon-dioxide sensors used in building HVAC applications. Fifteen models of NDIR HVAC-grade CO2 sensors were tested and evaluated to determine the accuracy, linearity, repeatability, and hysteresis of each sensor. This paper describes the performance of the sensors and provides a comparison with the manufacturers specifications. The sensors were tested at 40% relative humidity, 73oF (22.8oC) temperature, 14.70 psia (101.35 kPa) pressure, and at five different CO2 concentrations (400 ppm, 750 ppm, 1100 ppm, 1450 ppm, and 1800 ppm). The test results showed a wide variation in sensor performance among the various manufacturers and in some cases a wide variation among sensors of the same model. In all, 45 sensors were evaluated: three from each of the 15 models. Among the 15 models tested, eight models have a single-lamp, single-wavelength configuration, four models have a dual-lamp, single-wavelength configuration, and three models have a single-lamp, dual-wavelength configuration.

Shrestha, Som S [ORNL; Maxwell, Dr. Gregory [Iowa State University

2010-01-01T23:59:59.000Z

307

Model documentation: Natural gas transmission and distribution model of the National Energy Modeling System. Volume 1  

SciTech Connect

The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of integrated Analysis and Forecasting of the Energy information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The methodology employed allows the analysis of impacts of regional capacity constraints in the interstate natural gas pipeline network and the identification of pipeline capacity expansion requirements. There is an explicit representation of core and noncore markets for natural gas transmission and distribution services, and the key components of pipeline tariffs are represented in a pricing algorithm. Natural gas pricing and flow patterns are derived by obtaining a market equilibrium across the three main elements of the natural gas market: the supply element, the demand element, and the transmission and distribution network that links them. The NGTDM consists of four modules: the Annual Flow Module, the Capacity F-expansion Module, the Pipeline Tariff Module, and the Distributor Tariff Module. A model abstract is provided in Appendix A.

NONE

1995-02-17T23:59:59.000Z

308

Predicting particle deposition on HVAC heat exchangers  

E-Print Network (OSTI)

gas-side of finned tube heat- exchangers. Journal of Heatsurface interactions in heat exchanger fouling. Journal ofParticle Deposition on Heat Exchangers Epstein, N. , 1988.

Siegel, J A; Nazaroff, William W

2003-01-01T23:59:59.000Z

309

Variable-speed blower motors gaining ground in residential HVAC market  

SciTech Connect

Variable-speed blowers with electronically commutated permanent-magnet motors are gaining ground in the residential forced-air HVAC market. Variable-speed blower motors offer better comfort, better air mixing, lower noise, and tighter temperature and humidity control, as well as higher efficiency and lower peak demand than the constant-speed blower motors installed in most standard systems. Although these benefits cost considerably more up front, some homeowners think the extra cost is justified. Sales are increasing dramatically, and although variable-speed units made up less than three percent of the market in 1993, industry representatives predict that variable-speed blower motors may become the standard within ten to twenty years. The benefits of variable-speed gas furnaces also open up the potential for collaboration between gas and electric utilities. The best way for an electric utility to encourage customers to consider variable-speed gas furnaces may be through the gas utility, since homeowners look to the gas utility when it`s time to make a decision about a gas furnace purchase. Gas utilities can also benefit from variable speed by providing their customers better comfort, and possibly by reducing the customer`s gas bill (due to zoning or better control).

Gregerson, J.

1994-12-31T23:59:59.000Z

310

Modelling the natural gas consumption in a changing environment  

Science Conference Proceedings (OSTI)

A composite function was used successfully for modelling the Natural Gas (NG) consumption in 16 European energy markets. Background of the model is a logistic function where the upper limit is also a logistic function of time, with secondary parameters ...

F. A. Batzias; N. P. Nikolaou; A. S. Kakos; I. Michailides

2003-09-01T23:59:59.000Z

311

CFD Modelling of Generic Gas Turbine Combustor.  

E-Print Network (OSTI)

??New computational methods are continuously developed in order to solve problems in different engineering fields. One of these fields is gas turbines, where the challenge… (more)

KHODABANDEH, AMIR

2011-01-01T23:59:59.000Z

312

Gas Turbine Plant Modeling for Dynamic Simulation.  

E-Print Network (OSTI)

?? Gas turbines have become effective in industrial applications for electric and thermal energy production partly due to their quick response to load variations. A… (more)

Endale Turie, Samson

2012-01-01T23:59:59.000Z

313

An Experimental Evaluation of HVAC-Grade Carbon-Dioxide Sensors: Part 3, Humidity, Temperature, and Pressure Sensitivity Test Results  

Science Conference Proceedings (OSTI)

This is the third paper in a four-part series reporting on the test and evaluation of typical carbon-dioxide sensors used in building HVAC applications. Fifteen models of NDIR HVAC-grade CO2 sensors were tested and evaluated to determine the humidity, temperature, and pressure sensitivity of the sensors. This paper reports the performance of the sensors at various relative humidity, temperature, and pressure levels common to building HVAC applications and provides a comparison with manufacturer specifications. Among the 15 models tested, eight models have a single-lamp, single-wavelength configuration, four models have a dual-lamp, single-wavelength configuration, and three models have a single-lamp, dual-wavelength configuration. The sensors were tested in a chamber specifically fabricated for this research. A description of the apparatus and the method of test are described in Part 1 (Shrestha and Maxwell 2009). The test result showed a wide variation in humidity, temperature, and pressure sensitivity of CO2 sensors among manufacturers. In some cases, significant variations in sensor performance exist between sensors of the same model. Even the natural variation in relative humidity could significantly vary readings of some CO2 sensor readings. The effects of temperature and pressure variation on NDIR CO2 sensors are unavoidable without an algorithm to compensate for the changes. For the range of temperature and pressure variation in an air-conditioned space, the effect of pressure variation is more significant compared to the effect of temperature variation.

Shrestha, Som S [ORNL; Maxwell, Dr. Gregory [Iowa State University

2010-01-01T23:59:59.000Z

314

Thermovote: participatory sensing for efficient building HVAC conditioning  

Science Conference Proceedings (OSTI)

Thermal comfort has traditionally been measured solely by temperature. While other methods such as Predicted Mean Vote (PMV) are available for measuring thermal comfort, the parameters required for an accurate value are overly complicated to obtain and ... Keywords: HVAC conditioning, PMV, phones, thermal comfort

Varick L. Erickson; Alberto E. Cerpa

2012-11-01T23:59:59.000Z

315

Fuzzy Control of HVAC Systems Optimized by Genetic Algorithms  

Science Conference Proceedings (OSTI)

This paper presents the use of genetic algorithms to develop smartly tuned fuzzy logic controllers dedicated to the control of heating, ventilating and air conditioning systems concerning energy performance and indoor comfort requirements. This problem ... Keywords: HVAC systems, fuzzy logic controllers, genetic tuning, multiple criteria

Rafael Alcalá; Jose M. Benítez; Jorge Casillas; Oscar Cordón; Raúl Pérez

2003-03-01T23:59:59.000Z

316

Solar House Sink Group HVAC System Design Final Report  

E-Print Network (OSTI)

In this project we apply a systems engineering approach to design an intelligent HVAC system. Using sensors and user provided information the systems determines and adjusts the cooling load on the fly to provide the most efficient operation possible, saving energy and money. The system utilizes variable speed drives to provide just enough capacity to keep the indoor

Bob Hayes; Will Seeber; Zhen Zhao; Zhen Kuang; Isr Advisor; Prof Austin; Prof Baras

2011-01-01T23:59:59.000Z

317

HVAC System Design Strategies to Address Indoor Air Quality Standards  

Science Conference Proceedings (OSTI)

This report describes strategies that can be employed in the design and operation of heating, ventilating, and air conditioning (HVAC) systems to address the ASHRAE Standard 62 "Ventilation for Acceptable Indoor Air Quality" requirements. The report examines a wide variety of approaches to meeting the standard and their impact on energy consumption, occupant comfort, and other factors.

1999-12-09T23:59:59.000Z

318

Field Evaluation of Desiccant-Integrated HVAC Systems: A Review of Case Studies in Multiple Commercial/Institutional Building Types  

E-Print Network (OSTI)

An independent field research effort co-funded by the Gas Research Institute and The U.S. Department of Energy (DOE) Oak Ridge National Laboratory is documenting the performance and energy usage characteristics of active desiccant-integrated HVAC systems at a variety of commercial and institutional facilities. The tests comprise the instrumentation and one-year-plus monitoring of two or more nearly identical sites, one serving as the test site and the others as base-case or control sites. While the research program is ongoing, work completed in two market sectors, retail and lodging, indicates that there are significant comfort control, energy usage and equipment efficiency benefits to be derived from integrating desiccant units into HVAC system design to handle latent and sensible loads independently. In some cases, installed first costs associated with including desiccant units may be lower if the HVAC system is optimized to take advantage of reduced conventional cooling equipment requirements and downsized ductwork In most cases, lower energy consumption and/or reduced energy costs may provide reasonable payback of first cost premiums.

Yborra, S. C.

1998-01-01T23:59:59.000Z

319

The National Energy Modeling System: An Overview 1998 - Natural Gas  

Gasoline and Diesel Fuel Update (EIA)

NATURAL GAS TRANSMISSION AND DISTRIBUTION MODULE NATURAL GAS TRANSMISSION AND DISTRIBUTION MODULE blueball.gif (205 bytes) Annual Flow Submodule blueball.gif (205 bytes) Capacity Expansion Submodule blueball.gif (205 bytes) Pipeline Tariff Submodule blueball.gif (205 bytes) Distributor Tariff Submodule The natural gas transmission and distribution module (NGTDM) is the component of NEMS that represents the natural gas market. The NGTDM models the natural gas transmission and distribution network in the lower 48 States, which links suppliers (including importers) and consumers of natural gas. The module determines regional market-clearing prices for natural gas supplies (including border prices) and end-use consumption. The NGTDM has four primary submodules: the annual flow submodule, the capacity expansion submodule, the pipeline tariff submodule, and the

320

Oil and Gas Supply Module (OGSM), 2009, Model Documentation  

Reports and Publications (EIA)

Defines the objectives of the Oil and Gas Supply Model (OGSM), to describe the model's basic approach, and to provide detail on how the model works. This report is intended as a reference document for model analysts, users, and the public.

Dana Van-Wagener

2009-07-07T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Oil and Gas Supply Module (OGSM), 2007, Model Documentation  

Reports and Publications (EIA)

Defines the objectives of the Oil and Gas Supply Model (OGSM), to describe the model's basic approach, and to provide detail on how the model works. This report is intended as a reference document for model analysts, users, and the public.

Information Center

2007-08-14T23:59:59.000Z

322

Oil and Gas Supply Module (OGSM), 2002, Model Documentation  

Reports and Publications (EIA)

Defines the objectives of the Oil and Gas Supply Model (OGSM), to describe the model's basic approach, and to provide detail on how the model works. This report is intended as a reference document for model analysts, users, and the public.

Information Center

2002-03-01T23:59:59.000Z

323

Oil and Gas Supply Module (OGSM), 1998, Model Documentation  

Reports and Publications (EIA)

Defines the objectives of the Oil and Gas Supply Model (OGSM), to describe the model's basic approach, and to provide detail on how the model works. This report is intended as a reference document for model analysts, users, and the public.

Information Center

1998-01-01T23:59:59.000Z

324

Oil and Gas Supply Module (OGSM), 1995, Model Documentation  

Reports and Publications (EIA)

Defines the objectives of the Oil and Gas Supply Model (OGSM), to describe the model's basic approach, and to provide detail on how the model works. This report is intended as a reference document for model analysts, users, and the public.

Information Center

1996-01-01T23:59:59.000Z

325

Oil and Gas Supply Module (OGSM), 2008, Model Documentation  

Reports and Publications (EIA)

Defines the objectives of the Oil and Gas Supply Model (OGSM), to describe the model's basic approach, and to provide detail on how the model works. This report is intended as a reference document for model analysts, users, and the public.

Dana Van-Wagener

2008-10-14T23:59:59.000Z

326

Oil and Gas Supply Module (OGSM), 2006, Model Documentation  

Reports and Publications (EIA)

Defines the objectives of the Oil and Gas Supply Model (OGSM), to describe the model's basic approach, and to provide detail on how the model works. This report is intended as a reference document for model analysts, users, and the public.

Information Center

2006-03-01T23:59:59.000Z

327

Oil and Gas Supply Module (OGSM), 1999, Model Documentation  

Reports and Publications (EIA)

Defines the objectives of the Oil and Gas Supply Model (OGSM), to describe the model's basic approach, and to provide detail on how the model works. This report is intended as a reference document for model analysts, users, and the public.

Information Center

1999-02-01T23:59:59.000Z

328

Oil and Gas Supply Module (OGSM), 1997, Model Documentation  

Reports and Publications (EIA)

Defines the objectives of the Oil and Gas Supply Model (OGSM), to describe the model's basic approach, and to provide detail on how the model works. This report is intended as a reference document for model analysts, users, and the public.

Information Center

1997-01-01T23:59:59.000Z

329

Oil and Gas Supply Module (OGSM), 2000, Model Documentation  

Reports and Publications (EIA)

Defines the objectives of the Oil and Gas Supply Model (OGSM), to describe the model's basic approach, and to provide detail on how the model works. This report is intended as a reference document for model analysts, users, and the public.

Information Center

2000-01-01T23:59:59.000Z

330

Oil and Gas Supply Module (OGSM), 2004, Model Documentation  

Reports and Publications (EIA)

Defines the objectives of the Oil and Gas Supply Model (OGSM), to describe the model's basic approach, and to provide detail on how the model works. This report is intended as a reference document for model analysts, users, and the public.

Information Center

2004-03-01T23:59:59.000Z

331

Oil and Gas Supply Module (OGSM), 2001, Model Documentation  

Reports and Publications (EIA)

Defines the objectives of the Oil and Gas Supply Model (OGSM), to describe the model's basic approach, and to provide detail on how the model works. This report is intended as a reference document for model analysts, users, and the public.

Information Center

2001-01-01T23:59:59.000Z

332

Oil and Gas Supply Module (OGSM), 2005, Model Documentation  

Reports and Publications (EIA)

Defines the objectives of the Oil and Gas Supply Model (OGSM), to describe the model's basic approach, and to provide detail on how the model works. This report is intended as a reference document for model analysts, users, and the public.

Information Center

2005-05-01T23:59:59.000Z

333

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System  

NLE Websites -- All DOE Office Websites (Extended Search)

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage Title Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage Publication Type Conference Proceedings Refereed Designation Refereed LBNL Report Number LBNL-6127E Year of Publication 2013 Authors Mammoli, Andrea, Michael Stadler, Nicholas DeForest, Hans Barsun, Richard Burnett, and Chris Marnay Conference Name 3rd International Conference on Microgeneration and Related Technologies Date Published 04/2013 Conference Location Naples, Italy Keywords absorption cooling, mixed integer programming, optimisation, software-as-a-service, thermal storage Abstract The UNM Mechanical Engineering HVAC system incorporates cooling assisted by a 232 m2 solar thermal array providing heat to a 70 kWthermal absorption chiller. A 30 m3 heat storage tank solar decouples heat production and absorption cooling. Additionally, 350 m3 of chilled water storage shifts the cooling electrical load of this high desert location off-peak. While this system already provides substantial energy and cost savings compared to similar conventional buildings, there are still opportunities for improvement. Absorption cooling (augmented by an electrically powered central cooling loop) suffers from parasitic electric loads from a cooling tower pump, a cooling tower fan, and hot and chilled water circulation pumps. Moreover, depending on seasonal, weather, occupancy, and cost conditions, the cold storage tanks may only need partial charging to meet the next day's net building load, and losses need to be considered. Optimally operating this complex thermal-electrical system poses a challenging mathematical problem. A model of the system was built on LBNL's Distributed Resources Customer Adoption Model (DER-CAM) platform. A direct interface between the building energy control system, and DER-CAM hosted on LBNL's server was developed. This interface delivers daily scheduling based on weather forecasts, tariffs, etc., to the building controller. It is found that energy cost savings can be proportionally substantial (almost 30%) - although in this case the payback period for system implementation is long, due to the very low energy consumption of the building. Also, it is found that accurate weather forecasting is a key ingredient of the optimization, although local biases can be corrected for in the optimization.

334

Lattice gas models derived from effective field theory  

E-Print Network (OSTI)

We start from a low-energy effective field theory for interacting fermions on the lattice and expand in the hopping parameter to derive the nearest-neighbor interactions for a lattice gas model. In this model the renormalization of couplings for different lattice spacings is inherited from the effective field theory, systematic errors can be estimated a priori, and the breakdown of the lattice gas model description at low temperatures can be understood quantitatively. We apply the lattice gas method to neutron matter and compare with results from a recent quantum simulation.

Matthew Hamilton; Iyam Lynch; Dean Lee

2004-12-03T23:59:59.000Z

335

Holographic Dark Energy Model with Modified Variable Chaplygin Gas  

E-Print Network (OSTI)

In this letter we consider a correspondence between holographic dark energy and variable modified Chaplygin gas to obtain a holographic dark energy model of the universe. The corresponding potential of the scalar field has been reconstructed which describes the modified variable Chaplygin gas. The stability of the holographic dark energy in this case is also discussed.

B. C. Paul

2010-06-17T23:59:59.000Z

336

Revisions to the hydrogen gas generation computer model  

DOE Green Energy (OSTI)

Waste Management Technology has requested SRTC to maintain and extend a previously developed computer model, TRUGAS, which calculates hydrogen gas concentrations within the transuranic (TRU) waste drums. TRUGAS was written by Frank G. Smith using the BASIC language and is described in the report A Computer Model of gas Generation and Transport within TRU Waste Drums (DP- 1754). The computer model has been partially validated by yielding results similar to experimental data collected at SRL and LANL over a wide range of conditions. The model was created to provide the capability of predicting conditions that could potentially lead to the formation of flammable gas concentrations within drums, and to assess proposed drum venting methods. The model has served as a tool in determining how gas concentrations are affected by parameters such as filter vent sizes, waste composition, gas generation values, the number and types of enclosures, water instrusion into the drum, and curie loading. The success of the TRUGAS model has prompted an interest in the program`s maintenance and enhancement. Experimental data continues to be collected at various sites on such parameters as permeability values, packaging arrangements, filter designs, and waste contents. Information provided by this data is used to improve the accuracy of the model`s predictions. Also, several modifications to the model have been made to enlarge the scope of problems which can be analyzed. For instance, the model has been used to calculate hydrogen concentrations inside steel cabinets containing retired glove boxes (WSRC-RP-89-762). The revised TRUGAS computer model, H2GAS, is described in this report. This report summarizes all modifications made to the TRUGAS computer model and provides documentation useful for making future updates to H2GAS.

Jerrell, J.W.

1992-08-31T23:59:59.000Z

337

Revisions to the hydrogen gas generation computer model  

DOE Green Energy (OSTI)

Waste Management Technology has requested SRTC to maintain and extend a previously developed computer model, TRUGAS, which calculates hydrogen gas concentrations within the transuranic (TRU) waste drums. TRUGAS was written by Frank G. Smith using the BASIC language and is described in the report A Computer Model of gas Generation and Transport within TRU Waste Drums (DP- 1754). The computer model has been partially validated by yielding results similar to experimental data collected at SRL and LANL over a wide range of conditions. The model was created to provide the capability of predicting conditions that could potentially lead to the formation of flammable gas concentrations within drums, and to assess proposed drum venting methods. The model has served as a tool in determining how gas concentrations are affected by parameters such as filter vent sizes, waste composition, gas generation values, the number and types of enclosures, water instrusion into the drum, and curie loading. The success of the TRUGAS model has prompted an interest in the program's maintenance and enhancement. Experimental data continues to be collected at various sites on such parameters as permeability values, packaging arrangements, filter designs, and waste contents. Information provided by this data is used to improve the accuracy of the model's predictions. Also, several modifications to the model have been made to enlarge the scope of problems which can be analyzed. For instance, the model has been used to calculate hydrogen concentrations inside steel cabinets containing retired glove boxes (WSRC-RP-89-762). The revised TRUGAS computer model, H2GAS, is described in this report. This report summarizes all modifications made to the TRUGAS computer model and provides documentation useful for making future updates to H2GAS.

Jerrell, J.W.

1992-08-31T23:59:59.000Z

338

Empirical Math Model: Ideal Gas Law | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Empirical Math Model: Ideal Gas Law Empirical Math Model: Ideal Gas Law Empirical Math Model: Ideal Gas Law January 29, 2013 - 9:54am Addthis What are the key facts? Empirical models are generally most useful in describing conditions close to the experiments used to develop or calibrate them. Predictive tools are essential to understanding phenomena that can not be described experimentally, like used fuel behavior over thousands of years in a repository. Predictability is measured by understanding errors where they are introduced as well as to what degree they are quantified. To appreciate the distinction between curve fitting and what it means for a tool to be truly predictive it might help to consider how the ideal gas law was developed. In 1663, Robert Boyle performed a series of experiments at room temperature

339

Empirical Math Model: Ideal Gas Law | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Empirical Math Model: Ideal Gas Law Empirical Math Model: Ideal Gas Law Empirical Math Model: Ideal Gas Law January 29, 2013 - 9:54am Addthis What are the key facts? Empirical models are generally most useful in describing conditions close to the experiments used to develop or calibrate them. Predictive tools are essential to understanding phenomena that can not be described experimentally, like used fuel behavior over thousands of years in a repository. Predictability is measured by understanding errors where they are introduced as well as to what degree they are quantified. To appreciate the distinction between curve fitting and what it means for a tool to be truly predictive it might help to consider how the ideal gas law was developed. In 1663, Robert Boyle performed a series of experiments at room temperature

340

Using Coupled Harmonic Oscillators to Model Some Greenhouse Gas Molecules  

Science Conference Proceedings (OSTI)

Common greenhouse gas molecu les SF 6 NO 2 CH 4 and CO 2 are modeled as harmonic oscillators whose potential and kinetic energies are derived. Using the Euler?Lagrange equation

Clark Kendrick C. Go; Joel T. Maquiling

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Using multi-layer models to forecast gas flow rates in tight gas reservoirs  

E-Print Network (OSTI)

The petroleum industry commonly uses single-layer models to characterize and forecast long-term production in tight gas reservoir systems. However, most tight gas reservoirs are layered systems where the permeability and porosity of each layer can vary significantly, often over several orders of magnitude. In addition, the drainage areas of each of the layers can be substantially different. Due to the complexity of such reservoirs, the analysis of pressure and production history using single-layer analyses techniques provide incorrect estimates of permeability, fracture conductivity, drainage area, and fracture half-length. These erroneous values of reservoir properties also provide the reservoir engineer with misleading values of forecasted gas recovery. The main objectives of this research project are: (1) to demonstrate the typical errors that can occur in reservoir properties when single-layer modeling methods are used to history match production data from typical layered tight gas reservoirs, and (2) to use the single-layer match to demonstrate the error that can occur when forecasting long-term gas production for such complex gas reservoirs. A finite-difference reservoir simulator was used to simulate gas production from various layered tight gas reservoirs. These synthetic production data were analyzed using single-layer models to determine reservoir properties. The estimated reservoir properties obtained from the history matches were then used to forecast ten years of cumulative gas production and to find the accuracy of gas reserves estimated for tight gas reservoirs when a single-layer model is used for the analysis. Based on the results obtained in this work, I conclude that the accuracy in reservoir properties and future gas flow rates in layered tight gas reservoirs when analyzed using a single-layer model is a function of the degree of variability in permeability within the layers and the availability of production data to be analyzed. In cases where there is an idea that the reservoir presents a large variability in ��k�, using a multi-layer model to analyze the production data will provide the reservoir engineer with more accurate estimates of long-term production recovery and reservoir properties.

Jerez Vera, Sergio Armando

2006-12-01T23:59:59.000Z

342

This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (http://www.hvac.okstate.edu).  

E-Print Network (OSTI)

at Oklahoma State University (http://www.hvac.okstate.edu). The correct citation for the paper is: Spitler, J.D. 2007. Research Planning for the HVAC&R Industry. HVAC&R Research 13(5):681- 682. #12;VOLUME 13, NUMBER 5 HVAC&R RESEARCH SEPTEMBER 2007 681 EDITORIAL Research Planning for the HVAC&R Industry Jeffrey D

343

Sensitivity analysis of the fission gas behavior model in BISON.  

Science Conference Proceedings (OSTI)

This report summarizes the result of a NEAMS project focused on sensitivity analysis of a new model for the fission gas behavior (release and swelling) in the BISON fuel performance code of Idaho National Laboratory. Using the new model in BISON, the sensitivity of the calculated fission gas release and swelling to the involved parameters and the associated uncertainties is investigated. The study results in a quantitative assessment of the role of intrinsic uncertainties in the analysis of fission gas behavior in nuclear fuel.

Swiler, Laura Painton; Pastore, Giovanni [Idaho National Laboratory, Idaho Fall, ID; Perez, Danielle [Idaho National Laboratory, Idaho Fall, ID; Williamson, Richard [Idaho National Laboratory, Idaho Fall, ID

2013-05-01T23:59:59.000Z

344

Model documentation Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1  

Science Conference Proceedings (OSTI)

The Natural Gas Transmission and Distribution Model (NGTDM) of the National Energy Modeling System is developed and maintained by the Energy Information Administration (EIA), Office of Integrated Analysis and Forecasting. This report documents the archived version of the NGTDM that was used to produce the natural gas forecasts presented in the Annual Energy Outlook 1996, (DOE/EIA-0383(96)). The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic approach, and provides detail on the methodology employed. Previously this report represented Volume I of a two-volume set. Volume II reported on model performance, detailing convergence criteria and properties, results of sensitivity testing, comparison of model outputs with the literature and/or other model results, and major unresolved issues.

NONE

1996-02-26T23:59:59.000Z

345

HVAC Chiller Plant Screening Case Studies  

Science Conference Proceedings (OSTI)

EPRI's ChillerCalc software program is a useful tool for analyzing first-order comparative studies of chiller plant energy use, environmental performance, and economics. Hybrid cooling systems, which combine gas-fired and electric-driven chilling equipment, are emerging as a strategy to reduce central plant-related energy and demand costs. Although originally designed to analyze one-fuel type chillers at a time, ChillerCalc's capabilities were stretched to analyze hybrid systems. This report details the ...

2000-12-14T23:59:59.000Z

346

HVAC Optimized Heat Exchangers Research Project | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Optimized Heat Exchangers Research Optimized Heat Exchangers Research Project HVAC Optimized Heat Exchangers Research Project The U.S. Department of Energy is currently conducting research into heating, ventilation, and air conditioning (HVAC) optimized heat exchangers. The information generated in this study will demonstrate performance improvements that can be achieved through optimization of refrigerant circuitry for non-uniform inlet air distribution. The tubing circuitry on fin-tube heat exchangers used in residential space-conditioning systems is typically designed assuming uniform airflow through the finned passageways. However, the air flow in installed systems is highly non-uniform, resulting in mismatched refrigerant-air heat transfer that reduces the capacity of the heat exchanger and efficiency of

347

HVAC Radial Air Bearing Heat Exchangers Research Project | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radial Air Bearing Heat Exchangers Radial Air Bearing Heat Exchangers Research Project HVAC Radial Air Bearing Heat Exchangers Research Project The U.S. Department of Energy is currently conducting research into heating, ventilation, and air conditioning (HVAC) radial air bearing heat exchangers. Rotary air bearing heat exchanger technology simultaneously solves four long standing problems of conventional "fan-plus-finned-heat-sink" heat exchangers. Project Description This project seeks to design, fabricate, and test successive generations of prototype radial air bearing heat exchanger devices based on lessons learned and further insights into device optimization, computational fluid dynamic studies for parametric optimization and determination of scaling laws, and laboratory measurement of flow field and heat transfer

348

Optimizing HVAC Control to Improve Building Comfort and Energy Performance  

E-Print Network (OSTI)

This paper demonstrates the benefits of optimal control in well-designed and operated buildings using a case study. The case study building was built in 2001. The HVAC and control systems have been installed with state-of-the-art equipment which include a terminal box temperature integrated minimum airflow reset. The building has been used and operated based on the design intents. This paper presents both the existing and the optimal control schedules, which include the VAV box operation schedule, AHUs optimal control, chiller and chilled water pump control, and boiler and hot water pump control. The measured hourly HVAC electricity consumption shows that annual savings of up to 40% can be achieved with an optimal control schedule.

Song, L.; Joo, I.; Dong, D.; Liu, M.; Wang, J.; Hansen, K.; Quiroz, L.; Swiatek, A.

2003-01-01T23:59:59.000Z

349

Dynamic Absorption Model for Off-Gas Separation  

Science Conference Proceedings (OSTI)

Modeling and simulations will aid in the future design of U.S. advanced reprocessing plants for the recovery and recycle of actinides in used nuclear fuel. The specific fuel cycle separation process discussed in this report is the off-gas treatment system. The off-gas separation consists of a series of scrubbers and adsorption beds to capture constituents of interest. Dynamic models are being developed to simulate each unit operation involved so each unit operation can be used as a stand-alone model and in series with multiple others. Currently, a rate based, dynamic absorption model is being developed in gPROMS software. Inputs include liquid and gas stream constituents, column properties, liquid and gas phase reactions, number of stages, and inlet conditions. It simulates multiple component absorption with countercurrent flow and accounts for absorption by mass transfer and chemical reaction. The assumption of each stage being a discrete well-mixed entity was made. Therefore, the model is solved stagewise. The simulation outputs component concentrations in both phases as a function of time from which the rate of absorption is determined. Temperature of both phases is output as a function of time also. The model will be used able to be used as a standalone model in addition to in series with other off-gas separation unit operations. The current model is being generated based on NOx absorption; however, a future goal is to develop a CO2 specific model. The model will have the capability to be modified for additional absorption systems. The off-gas models, both adsorption and absorption, will be made available via the server or web for evaluation by customers.

Veronica J. Rutledge

2011-07-01T23:59:59.000Z

350

Outdoor airflow into HVAC systems: An evaluation of measurement  

NLE Websites -- All DOE Office Websites (Extended Search)

Outdoor airflow into HVAC systems: An evaluation of measurement Outdoor airflow into HVAC systems: An evaluation of measurement technologies Title Outdoor airflow into HVAC systems: An evaluation of measurement technologies Publication Type Report LBNL Report Number LBNL-53834 Year of Publication 2003 Authors Fisk, William J., David Faulkner, Douglas P. Sullivan, and William W. Delp Abstract During the last few years, new technologies have been introduced for measuring the flow rates of outdoor air (OA) into HVAC systems; however, an evaluation of these measurement technologies has not previously been published. This document describes a test system and protocols developed for controlled evaluation of these measurement technologies. The results of tests of three measurement technologies are also summarized. The test system and protocol were judged practical and very useful. The test results indicate that one measurement technology can measure OA flow rates with errors of 20% or less without a field-based calibration, as long as the OA velocities are sufficient to provide an accurately measurable pressure signal. The test results for a second measurement technology are similar; however, a difficult field-based calibration relating the OA flow rate with the pressure signal would be required to reduce errors below approximately 30%. The errors in OA flow rates measured with the third measurement technology, that uses six electronic airspeed sensors downstream of the OA inlet louver, exceeded 100%; however, these errors could be substantially reduced through a difficult field based calibration. The effects of wind on the accuracy of these measurement technologies still needs to be evaluated

351

Indoor Air Quality Primer for HVAC System Design  

Science Conference Proceedings (OSTI)

Heating, ventilating, and air conditioning (HVAC) systems are major energy users in commercial and institutional buildings. Increased ventilation for acceptable indoor air quality (IAQ), besides increasing energy use, may result in unacceptably high indoor humidity, particularly in humid climates and/or applications requiring high ventilation rates. This report analyzes how increased ventilation affects the dehumidification capabilities of air conditioning systems in three applications -- offices, retail...

2002-02-21T23:59:59.000Z

352

Computer program for conducting acoustical analyses of HVAC systems.  

Science Conference Proceedings (OSTI)

An interactive Windows?based computer program has been developed that can be used to conduct complete acoustical analyses of HVAC systems. The program can be used to track sound from a HVACsound source such as a fan to a room. Both sound from a single path between a sound source and room or from multiple paths between a sound source and room can be investigated. The program has a full set of editing features that include change

Douglas D. Reynolds; Scott C. Mitchell

1996-01-01T23:59:59.000Z

353

Gas permeation carbon capture --- Process modeling and optimization  

SciTech Connect

A multi-staged gas permeation carbon capture process model was developed in Aspen Custom Modeler{reg_sign} (ACM) and optimized in the context of the retrofit of a 550 MW subcritical pulverized coal (PC) power plant. The gas permeation stages in the process are described by a custom multi-component, hollowfiber membrane model. Gas transport across the asymmetric membrane was modeled according to the solution-diffusion model for the selective skin layer and the assumption of negligible flux resistance by the porous support. Counter-current, one-dimensional plug flow was assumed with permeate pressure drop in the fiber lumen side due to capillary constrained flow. A modular optimization framework was used to minimize the levelized cost of electricity (LCOE) by optimizing a set of key process variables. The framework allows the external control of multiple simulation modules from different software packages from a common interface.

Morinelly, Juan; Miller, David

2011-01-01T23:59:59.000Z

354

Two Alabama Elementary Schools Get Cool with New HVAC Units | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alabama Elementary Schools Get Cool with New HVAC Units Alabama Elementary Schools Get Cool with New HVAC Units Two Alabama Elementary Schools Get Cool with New HVAC Units October 1, 2010 - 2:05pm Addthis Winston County School District will receive 14 new HVAC units with State Energy Program funding. | File photo Winston County School District will receive 14 new HVAC units with State Energy Program funding. | File photo Lindsay Gsell What are the key facts? Two public elementary schools receive 14 new HVAC units for classrooms. School district estimates nearly 10 percent in electrical savings with new units. Nineteen Alabama public school districts using Recovery Act grants to save energy and money. Addison Elementary School and Double Springs Elementary School in northwestern Alabama were warm. Some classrooms just didn't cool fast enough. The buildings, which were

355

Nuclear liquid-gas phase transition within the lattice gas model  

E-Print Network (OSTI)

We study the nuclear liquid-gas phase transition on the basis of a two-component lattice gas model. A Metropolis type of sampling method is used to generate microscopic states in the canonical ensemble. The effective equation of state and fragment mass distributions are evaluated in a wide range of temperatures and densities. A definition of the phase coexistence region appropriate for mesoscopic systems is proposed. The caloric curve resulting from different types of freeze-out conditions are presented.

J. Borg; I. N. Mishustin; J. P. Bondorf

1998-09-25T23:59:59.000Z

356

HVAC&R Equipment Performance Group  

Science Conference Proceedings (OSTI)

... which is the predominant end-user of energy in buildings. ... and components; development of advanced modeling and optimization tools; research of ...

2012-05-16T23:59:59.000Z

357

ConEd (Gas)- Residential Energy Efficiency Incentives Program  

Energy.gov (U.S. Department of Energy (DOE))

Con Edison is offering the Residential HVAC Gas Rebate Program. Through this program, incentives are offered on energy efficient heating and cooling equipment for residences in the eligible service...

358

Buildings, Energy, Greenhouse Gas, Industrial and Policy Modeling and  

NLE Websites -- All DOE Office Websites (Extended Search)

Buildings, Energy, Greenhouse Gas, Industrial and Policy Modeling and Buildings, Energy, Greenhouse Gas, Industrial and Policy Modeling and Simulation Tools Available from Energy Analysis and Environmental Impacts Department Tools header image January 2014 Tools and models to find the best way to save energy and reduce greenhouse gas emissions in cities and industries, to follow the transport of pollutants through the environment, and to calculate the cost of power interruptions are among those available on a new Lawrence Berkeley National Laboratory (Berkeley Lab) web site. The site brings together models and simulation tools developed by the Energy Analysis and Environmental Impacts (EAEI) Department of the Lab's Environmental Energy Technologies Division. "Our hope is that the site will facilitate greater technical awareness of

359

Joint Modelling of Gas and Electricity spot prices  

E-Print Network (OSTI)

The recent liberalization of the electricity and gas markets has resulted in the growth of energy exchanges and modelling problems. In this paper, we modelize jointly gas and electricity spot prices using a mean-reverting model which fits the correlations structures for the two commodities. The dynamics are based on Ornstein processes with parameterized diffusion coefficients. Moreover, using the empirical distributions of the spot prices, we derive a class of such parameterized diffusions which captures the most salient statistical properties: stationarity, spikes and heavy-tailed distributions. The associated calibration procedure is based on standard and efficient statistical tools. We calibrate the model on French for electricity and on UK market for gas, and then simulate some trajectories which reproduce well the observed prices behavior. Finally, we illustrate the importance of the correlation structure and of the presence of spikes by measuring the risk on a power plant portfolio.

Frikha, Noufel

2009-01-01T23:59:59.000Z

360

Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable-Speed-Drive Chillers  

E-Print Network (OSTI)

the portion of chiller energy usage was significant. It is,Figure 1. Benchmarked HVAC energy usages in a semiconductor2. Benchmarked cleanroom energy usages in a semiconductor

Xu, Tengfang

2005-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

HVAC Right-Sizing Part 1-Calculating Loads | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

-Calculating Loads HVAC Right-Sizing Part 1-Calculating Loads During this webinar, Building America Research Team IBACOS highlighted the key criteria required to create accurate...

362

Energy and Cost Implications of the Florida Energy Star Residential HVAC Rebate Program.  

E-Print Network (OSTI)

??In July 2010, the Florida’s Governors Energy Office released the Florida ENERGY STAR Residential HVAC Rebate Program. The program was funded by a grant from… (more)

Strauss, Kurt

2012-01-01T23:59:59.000Z

363

Design Analysis and Experimental Investigation of the HVAC System in an IC Circuit Plant.  

E-Print Network (OSTI)

??It is the goal of this project to investigate the energy conservation measures which can be adapted in an electronic manufacturing plant HVAC system. Computer… (more)

Chang, I-wei

2005-01-01T23:59:59.000Z

364

Quiet unlined HVAC ductwork: Using active silencing to obtain NC?35 in buildings without fibrous materials  

Science Conference Proceedings (OSTI)

Fan noise in HVAC ducts has traditionally been attenuated with fibrous internal duct liner or with passive silencers constructed with porous fill material. Now

Steve Wise; Lawrence J. Gelin; Kirk G. Burlage; Susan H. Dineen

1995-01-01T23:59:59.000Z

365

HVAC Right-Sizing Part 1: Calculating Loads | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

: Calculating Loads HVAC Right-Sizing Part 1: Calculating Loads This webinar, presented by IBACOS (a Building America Research Team) will highlight the key criteria required to...

366

Numerical Investigation of Flow Induced Noise in a Simplified HVAC Duct with OpenFOAM.  

E-Print Network (OSTI)

?? Due to the growing demand for comfort, the noise generated by HVAC components should be considered by the designers. Flow induced noise is one… (more)

Wang, Cong

2013-01-01T23:59:59.000Z

367

Tecniche di machine learning per la ricerca guasti in impianti HVAC.  

E-Print Network (OSTI)

??Il corretto funzionamento degli impianti di tipo HVAC (Heating Ventilating and Air Conditioning) di taglia medio/grande, risulta cruciale al fine di garantire un adeguato livello… (more)

Corso, Lorenzo

2012-01-01T23:59:59.000Z

368

Analyzing money distributions in `ideal gas' models of markets  

E-Print Network (OSTI)

We analyze an ideal gas like models of a trading market. We propose a new fit for the money distribution in the fixed or uniform saving market. For the marketwith quenched random saving factors for its agents we show that the steady state income ($m$) distribution $P(m)$ in the model has a power law tail with Pareto index $\

Chatterjee, A; Stinchcombe, Robert B; Chatterjee, Arnab; Chakrabarti, Bikas K.; Stinchcombe, Robin B.

2005-01-01T23:59:59.000Z

369

Assessment of organic compound exposures, thermal comfort parameters, and HVAC system-driven air exchange rates in public school portable classrooms in California  

E-Print Network (OSTI)

SPECIFY UNITS) when heat (of HVAC) is turned off?using the heat (from HVAC)? A. B. C. D. January Februaryair conditionmg (from HVAC)? A. B. C. D. January February

Shendell, Derek Garth

2010-01-01T23:59:59.000Z

370

Isospin Lattice-Gas Model and Liquid-Gas Phase Transition in Asymmetric Nuclear Matter  

E-Print Network (OSTI)

An isospin lattice-gas model, which is a spin-1 Ising model, is employed to investigate the liquid-gas phase transition in asymmetric nuclear matter. We consider nuclear matter as a lattice where each lattice site can be either empty or occupied by a proton or a neutron, with a nearest-neighbor interaction among the nucleons. With the Bragg-Williams mean field approximation, we calculate various thermodynamic properties of nuclear matter for different densities and different proton-neutron asymmetry parameter $s$. Our model exhibits liquid-gas phase transition below a critical temperature $T_c$, and predicts a monotonic decreasing of $T_c$ as the magnitude of $s$ is increased. The dependence of the nuclear matter isotherms on the asymmetry parameter $s$ is discussed.

S. Ray; J. Shamanna; T. T. S. Kuo

1996-08-13T23:59:59.000Z

371

Isospin Lattice-Gas Model and Liquid-Gas Phase Transition in Asymmetric Nuclear Matter  

E-Print Network (OSTI)

An isospin lattice-gas model, which is a spin-1 Ising model, is employed to investigate the liquid-gas phase transition in asymmetric nuclear matter. We consider nuclear matter as a lattice where each lattice site can be either empty or occupied by a proton or a neutron, with a nearest-neighbor interaction among the nucleons. With the Bragg-Williams mean field approximation, we calculate various thermodynamic properties of nuclear matter for different densities and different proton-neutron asymmetry parameter s. Our model exhibits liquidgas phase transition below a critical temperature Tc, and predicts a monotonic decreasing of Tc as the magnitude of s is increased. The dependence of the nuclear matter isotherms on the asymmetry parameter s is discussed. Ray, Shamanna and Kuo / Liquid-gas phase transition in Nuclear matter 2 1.

S. Ray; J. Shamanna; T. T. S. Kuo

2008-01-01T23:59:59.000Z

372

Computer modeling of gas flow and gas loading of rock in a bench blasting environment  

SciTech Connect

Numerical modeling can contribute greatly to an understanding of the physics involved in the blasting process. This paper will describe the latest enhancements to the blast modeling code DMC (Distinct Motion Code) (Taylor and Preece, 1989) and will demonstrate the ability of DMC to model gas flow and rock motion in a bench blasting environment. DMC has been used previously to model rock motion associated with blasting in a cratering environment (Preece and Taylor, 1990) and in confined volume blasting associated with in-situ oil shale retorting (Preece, 1990 a b). These applications of DMC treated the explosive loading as force versus time functions on specific spheres which were adjusted to obtain correct face velocities. It was recognized that a great need in explosives modeling was the coupling of an ability to simulate gas flow with the rock motion simulation capability of DMC. This was accomplished by executing a finite difference code that computes gas flow through a porous media (Baer and Gross, 1989) in conjunction with DMC. The marriage of these two capabilities has been documented by Preece and Knudsen, 1991. The capabilities that have been added recently to DMC and which will be documented in this paper include: (1) addition of a new equation of state for the explosive gases; (2) modeling of gas flow and sphere loading in a bench environment. 8 refs., 5 figs.

Preece, D.S.; Baer, M.R. (Sandia National Labs., Albuquerque, NM (United States)); Knudsen, S.D. (RE/SPEC, Inc., Albuquerque, NM (United States))

1991-01-01T23:59:59.000Z

373

A Dark Energy model combining DGP gravity and Chaplygin gas  

E-Print Network (OSTI)

The expansion of the Universe is accelerating, as testified by observations of supernovae of type Ia as a function of redshift. Explanations are of two types: modifications of Einstein gravity or new forms of energy, coined dark energy.The accelerated expansion is explained here by a combination of Dvali-Gabadadze-Porrati (DGP) model gravity and Chaplygin gas dark energy. Both models are characterized by a length scale L which may be the same. The continuity equation for the combined model is derived in flat geometry, and solved by numerical methods. The solution is shown to have the expected properties: at very small scales (aenergy density behaves as pressureless dust, at very large scales (a>>L) as a cosmological constant. The modifications to the DGP model and the Chaplygin gas model occur for values of a L. The results show an increase in the present dark energy density relative to the plain DGP model.

Matts Roos

2007-04-06T23:59:59.000Z

374

Model documentation: Natural Gas Transmission and Distribution Model of the National Energy Modeling System; Volume 1  

SciTech Connect

The Natural Gas Transmission and Distribution Model (NGTDM) is a component of the National Energy Modeling System (NEMS) used to represent the domestic natural gas transmission and distribution system. NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the Energy Information Administration (EIA) and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. This report documents the archived version of NGTDM that was used to produce the natural gas forecasts used in support of the Annual Energy Outlook 1994, DOE/EIA-0383(94). The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic design, provides detail on the methodology employed, and describes the model inputs, outputs, and key assumptions. It is intended to fulfill the legal obligation of the EIA to provide adequate documentation in support of its models (Public Law 94-385, Section 57.b.2). This report represents Volume 1 of a two-volume set. (Volume 2 will report on model performance, detailing convergence criteria and properties, results of sensitivity testing, comparison of model outputs with the literature and/or other model results, and major unresolved issues.) Subsequent chapters of this report provide: (1) an overview of the NGTDM (Chapter 2); (2) a description of the interface between the National Energy Modeling System (NEMS) and the NGTDM (Chapter 3); (3) an overview of the solution methodology of the NGTDM (Chapter 4); (4) the solution methodology for the Annual Flow Module (Chapter 5); (5) the solution methodology for the Distributor Tariff Module (Chapter 6); (6) the solution methodology for the Capacity Expansion Module (Chapter 7); (7) the solution methodology for the Pipeline Tariff Module (Chapter 8); and (8) a description of model assumptions, inputs, and outputs (Chapter 9).

NONE

1994-02-24T23:59:59.000Z

375

An Equilibrium-Based Model of Gas Reaction and Detonation  

Science Conference Proceedings (OSTI)

During gaseous diffusion plant operations, conditions leading to the formation of flammable gas mixtures may occasionally arise. Currently, these could consist of the evaporative coolant CFC-114 and fluorinating agents such as F2 and ClF3. Replacement of CFC-114 with a non-ozone-depleting substitute is planned. Consequently, in the future, the substitute coolant must also be considered as a potential fuel in flammable gas mixtures. Two questions of practical interest arise: (1) can a particular mixture sustain and propagate a flame if ignited, and (2) what is the maximum pressure that can be generated by the burning (and possibly exploding) gas mixture, should it ignite? Experimental data on these systems, particularly for the newer coolant candidates, are limited. To assist in answering these questions, a mathematical model was developed to serve as a tool for predicting the potential detonation pressures and for estimating the composition limits of flammability for these systems based on empirical correlations between gas mixture thermodynamics and flammability for known systems. The present model uses the thermodynamic equilibrium to determine the reaction endpoint of a reactive gas mixture and uses detonation theory to estimate an upper bound to the pressure that could be generated upon ignition. The model described and documented in this report is an extended version of related models developed in 1992 and 1999.

Trowbridge, L.D.

2000-04-01T23:59:59.000Z

376

Beaird Maxim Model TRP-12 | Open Energy Information  

Open Energy Info (EERE)

TRP-12 Jump to: navigation, search Manufacturer Beaird Model Number Maxim Model TRP-12 Distributed Generation Purpose Domestic hot water, Space heat, HVAC reheat Retrieved from...

377

Gas Centrifuge Enrichment Plant Safeguards System Modeling  

SciTech Connect

The U.S. Department of Energy (DOE) is interested in developing tools and methods for potential U.S. use in designing and evaluating safeguards systems used in enrichment facilities. This research focuses on analyzing the effectiveness of the safeguards in protecting against the range of safeguards concerns for enrichment plants, including diversion of attractive material and unauthorized modes of use. We developed an Extend simulation model for a generic medium-sized centrifuge enrichment plant. We modeled the material flow in normal operation, plant operational upset modes, and selected diversion scenarios, for selected safeguards systems. Simulation modeling is used to analyze both authorized and unauthorized use of a plant and the flow of safeguards information. Simulation tracks the movement of materials and isotopes, identifies the signatures of unauthorized use, tracks the flow and compilation of safeguards data, and evaluates the effectiveness of the safeguards system in detecting misuse signatures. The simulation model developed could be of use to the International Atomic Energy Agency IAEA, enabling the IAEA to observe and draw conclusions that uranium enrichment facilities are being used only within authorized limits for peaceful uses of nuclear energy. It will evaluate improved approaches to nonproliferation concerns, facilitating deployment of enhanced and cost-effective safeguards systems for an important part of the nuclear power fuel cycle.

Elayat, H A; O'Connell, W J; Boyer, B D

2006-06-05T23:59:59.000Z

378

Off-gas Adsorption Model and Simulation - OSPREY  

Science Conference Proceedings (OSTI)

The absence of industrial scale nuclear fuel reprocessing in the U.S. has precluded the necessary driver for developing the advanced simulation capability now prevalent in so many other countries. Thus, it is essential to model complex series of unit operations to simulate, understand, and predict inherent transient behavior. A capability of accurately simulating the dynamic behavior of advanced fuel cycle separation processes is expected to provide substantial cost savings and many technical benefits. To support this capability, a modeling effort focused on the off-gas treatment system of a used nuclear fuel recycling facility is in progress. The off-gas separation consists of a series of scrubbers and adsorption beds to capture constituents of interest. Dynamic models are being developed to simulate each unit operation involved so each unit operation can be used as a stand-alone model and in series with multiple others. Currently, an adsorption model has been developed within Multi-physics Object Oriented Simulation Environment (MOOSE) developed at the Idaho National Laboratory (INL). Off-gas Separation and REcoverY (OSPREY) models the adsorption of offgas constituents for dispersed plug flow in a packed bed under non-isothermal and non-isobaric conditions. Inputs to the model include gas composition, sorbent and column properties, equilibrium and kinetic data, and inlet conditions. The simulation outputs component concentrations along the column length as a function of time from which breakthrough data can be obtained. The breakthrough data can be used to determine bed capacity, which in turn can be used to size columns. In addition to concentration data, the model predicts temperature along the column length as a function of time and pressure drop along the column length. A description of the OSPREY model, results from krypton adsorption modeling and plans for modeling the behavior of iodine, xenon, and tritium will be discussed.

Veronica J Rutledge

2013-10-01T23:59:59.000Z

379

Procedures to identify Energy Conservation Opportunities applied to HVAC system: example of VSD of chilled water pumps  

E-Print Network (OSTI)

Procedures to identify Energy Conservation Opportunities applied to HVAC system: example of VSD of HVAC equipment using variable speed drive (VSD) is an Energy Conservation Opportunity (ECO) which can

Paris-Sud XI, Université de

380

Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1  

Science Conference Proceedings (OSTI)

The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic design, provides detail on the methodology employed, and describes the model inputs, outputs, and key assumptions. Subsequent chapters of this report provide: an overview of NGTDM; a description of the interface between the NEMS and NGTDM; an overview of the solution methodology of the NGTDM; the solution methodology for the Annual Flow Module; the solution methodology for the Distributor Tariff Module; the solution methodology for the Capacity Expansion Module; the solution methodology for the Pipeline Tariff Module; and a description of model assumptions, inputs, and outputs.

NONE

1998-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Source attenuating HVAC equipment—Just the facts  

Science Conference Proceedings (OSTI)

Current classroom designs range from NC 63 to NC 25. The ASA/ANSI 12.60 Classroom Standard sets a relatively low background sound requirement for classrooms. Achieving 12.60 levels economically requires the maximum in source sound attenuation. This paper will provide a manufacturer’s perspective on current and low noiseHVAC products and the resulting classroomsound levels. Predictive acoustics software will be used to predict the space sound power level and some indication of equipment cost will be provided in order to assist designers in what is the best approach to low noiseclassroom design.

2004-01-01T23:59:59.000Z

382

Creating a Virtual HVAC Laboratory for Continuing/Distance Education  

E-Print Network (OSTI)

Facilities engineering is one technical field where lab-based continuing education programs can be delivered in a distance learning format. The widespread use of computer controls for optimizing the efficiency of a building's mechanical and electrical systems has made the "distance" element possible. Rather than traveling to individual buildings to make pressure, temperature, and flow measurements in person, facility engineers routinely access performance data over the Internet. This networking capability has been used in an educational setting to deliver interactive technical training to large numbers of undergraduate students and professional facilities engineers. Many students can access real time data from a single piece of HVAC equipment over the Internet.

William J. Hutzel

2001-01-01T23:59:59.000Z

383

Proposal for the Award of a Contract for Maintenance, Operation and Minor Installation Work for CERN Cooling and HVAC Systems  

E-Print Network (OSTI)

Proposal for the Award of a Contract for Maintenance, Operation and Minor Installation Work for CERN Cooling and HVAC Systems

1996-01-01T23:59:59.000Z

384

ZonePAC: Zonal Power Estimation and Control via HVAC Metering and Occupant Feedback  

Science Conference Proceedings (OSTI)

Heating Ventillation and Air Conditioning (HVAC) systems account for nearly 40% of primary energy consumption by commercial buildings. Yet, these systems by and large operate in an open-loop with the building occupants. While the monitoring and feedback ... Keywords: Energy Estimation, HVAC, Thermostat, User Interface, Variable Air Volume

Bharathan Balaji, Hidetoshi Teraoka, Rajesh Gupta, Yuvraj Agarwal

2013-11-01T23:59:59.000Z

385

An "ageing" operator and its use in the highly constrained topological optimization of HVAC system design  

Science Conference Proceedings (OSTI)

The synthesis of novel heating, ventilating, and air-conditioning (HVAC), system configurations is a mixed-integer, non-linear, highly constrained, multi-modal, optimization problem, with many of the constraints being subject to time-varying boundary ... Keywords: HVAC, evolutionary algorithms, system design, topological optimization

Jonathan Wight; Yi Zhang

2005-06-01T23:59:59.000Z

386

Co-design of control algorithm and embedded platform for building HVAC systems  

Science Conference Proceedings (OSTI)

The design of heating, ventilation and air conditioning (HVAC) systems is crucial for reducing energy consumption in buildings. As complex cyber-physical systems, HVAC systems involve three closely-related subsystems -- the control algorithm, the physical ... Keywords: building energy efficiency, co-design, platform-based design

Mehdi Maasoumy, Qi Zhu, Cheng Li, Forrest Meggers, Alberto Sangiovanni-Vincentelli

2013-04-01T23:59:59.000Z

387

Airborne Particulate Matter in HVAC Systems and its Influence on Indoor Air Quality  

E-Print Network (OSTI)

This paper first reviews the mechanisms governing movement of PMs in HVAC systems. Then, the basic equations governing PM deposition in ducts are introduced and investigations on airborne PMs distribution in HVAC systems are reviewed. The influence of PMs on indoor air quality and effectiveness of corresponding controlling measures is discussed extensively in the paper. Finally, recommendations for further research are given.

Fu, Z.; Li, N.; Wang, H.

2006-01-01T23:59:59.000Z

388

Review of Pre- and Post-1980 Buildings in CBECS - HVAC Equipment  

SciTech Connect

PNNL was tasked by DOE to look at HVAC systems and equipment for Benchmark buildings based on 2003 CBECS data. This white paper summarizes the results of PNNL’s analysis of 2003 CBECS data and provides PNNL’s recommendations for HVAC systems and equipment for use in the Benchmark buildings.

Winiarski, David W.; Jiang, Wei; Halverson, Mark A.

2006-12-01T23:59:59.000Z

389

Feasibility of retrofitting centralized HVAC systems for room-level zoning  

Science Conference Proceedings (OSTI)

Heating, ventilation, and cooling (HVAC) accounts for 38% of building energy usage, and over 15% of all US energy usage, making it one of the nation's largest energy consumers. Many attempts have been made to optimize the control of HVAC systems by minimizing ... Keywords: sensing,Building energy,wireless sensor networks

Tamim Sookoor; Brian Holben; Kamin Whitehouse

2012-06-01T23:59:59.000Z

390

Wireless Demand Response Controls for HVAC Systems  

Science Conference Proceedings (OSTI)

The objectives of this scoping study were to develop and test control software and wireless hardware that could enable closed-loop, zone-temperature-based demand response in buildings that have either pneumatic controls or legacy digital controls that cannot be used as part of a demand response automation system. We designed a SOAP client that is compatible with the Demand Response Automation Server (DRAS) being used by the IOUs in California for their CPP program, design the DR control software, investigated the use of cellular routers for connecting to the DRAS, and tested the wireless DR system with an emulator running a calibrated model of a working building. The results show that the wireless DR system can shed approximately 1.5 Watts per design CFM on the design day in a hot, inland climate in California while keeping temperatures within the limits of ASHRAE Standard 55: Thermal Environmental Conditions for Human Occupancy.

Federspiel, Clifford

2009-06-30T23:59:59.000Z

391

Modeling acid-gas generation from boiling chloride brines  

Science Conference Proceedings (OSTI)

This study investigates the generation of HCl and other acid gases from boiling calcium chloride dominated waters at atmospheric pressure, primarily using numerical modeling. The main focus of this investigation relates to the long-term geologic disposal of nuclear waste at Yucca Mountain, Nevada, where pore waters around waste-emplacement tunnels are expected to undergo boiling and evaporative concentration as a result of the heat released by spent nuclear fuel. Processes that are modeled include boiling of highly concentrated solutions, gas transport, and gas condensation accompanied by the dissociation of acid gases, causing low-pH condensate. Simple calculations are first carried out to evaluate condensate pH as a function of HCl gas fugacity and condensed water fraction for a vapor equilibrated with saturated calcium chloride brine at 50-150 C and 1 bar. The distillation of a calcium-chloride-dominated brine is then simulated with a reactive transport model using a brine composition representative of partially evaporated calcium-rich pore waters at Yucca Mountain. Results show a significant increase in boiling temperature from evaporative concentration, as well as low pH in condensates, particularly for dynamic systems where partial condensation takes place, which result in enrichment of HCl in condensates. These results are in qualitative agreement with experimental data from other studies. The combination of reactive transport with multicomponent brine chemistry to study evaporation, boiling, and the potential for acid gas generation at the proposed Yucca Mountain repository is seen as an improvement relative to previously applied simpler batch evaporation models. This approach allows the evaluation of thermal, hydrological, and chemical (THC) processes in a coupled manner, and modeling of settings much more relevant to actual field conditions than the distillation experiment considered. The actual and modeled distillation experiments do not represent expected conditions in an emplacement drift, but nevertheless illustrate the potential for acid-gas generation at moderate temperatures (<150 C).

Zhang, Guoxiang; Spycher, Nicolas; Sonnenthal, Eric; Steefel, Carl

2009-11-16T23:59:59.000Z

392

Modeling the Gas By-products of Metalorganic Chemical Vapor ...  

Science Conference Proceedings (OSTI)

The fiber then proceeds through an inert gas seal, inlet cross, hot-wall reactor, ... The effluent flows through a burn box (heated to greater than 500°C) before ... involve transport-kinetic modeling that describes the fluid flow, heat transfer, and  ...

393

Modeling Swtichgrass Biomass Production and Associated Greenhouse Gas Emissions  

E-Print Network (OSTI)

Modeling Swtichgrass Biomass Production and Associated Greenhouse Gas Emissions Weiyuan Zhu, Johan in the atmosphere have led to renewed interest in energy from plant biomass. Surfing the internet or flipping to a series of concerns, apprehensions and challenges presented by a shift to a heavier reliance on biomass

California at Davis, University of

394

Proceedings of Healthy Buildings 2009 Paper 535 HVAC filters as "passive" samplers: fate analysis of indoor particles  

E-Print Network (OSTI)

Proceedings of Healthy Buildings 2009 Paper 535 HVAC filters as "passive" samplers: fate analysis: fedenoris@mail.utexas.edu SUMMARY To assess the potential use of HVAC filters as passive indoor samplers, exfiltration, and capture in the HVAC filter. The results suggest that large particles are likely to deposit

Siegel, Jeffrey

395

Simulation of Control Options for HVAC Management of a Typical Office Julien CAILLET julien.caillet@mines-paristech.fr  

E-Print Network (OSTI)

Simulation of Control Options for HVAC Management of a Typical Office Building. Julien CAILLET thermal comfort and to reduce energy consumption of buildings. Among defect correction, HVAC control appears as a way of significant improvement. HVAC control is examined by using a dynamic simulation

Paris-Sud XI, Université de

396

7/11/00-draft copy: do not quote 1 of 30 New Technologies for Residential HVAC Ducts  

E-Print Network (OSTI)

7/11/00-draft copy: do not quote 1 of 30 New Technologies for Residential HVAC Ducts Burke Treidler is not evaluated and HVAC contractors overcome duct system shortcomings by installing oversized equipment Technologies for Residential HVAC Ducts fittings with some use of ductboard. Fittings that snap together were

397

IEEE TRANSACTIONS ON COMMUNICATIONS, VOL. 53, NO. 2, FEBRUARY 2005 335 On the Capacity Limits of HVAC Duct Channel for  

E-Print Network (OSTI)

of HVAC Duct Channel for High-Speed Internet Access Ariton E. Xhafa, Member, IEEE, Ozan K. Tonguz, Member and experimental channel-capacity estimates of heating, ventilation, and air condi- tioning (HVAC) ducts based suppressed. Our experimental results also show that even in the case of more complex HVAC duct networks (i

Stancil, Daniel D.

398

1736 IEEE TRANSACTIONS ON COMMUNICATIONS, VOL. 51, NO. 10, OCTOBER 2003 Impulse Response of the HVAC Duct as a  

E-Print Network (OSTI)

of the HVAC Duct as a Communication Channel Pavel V. Nikitin, Member, IEEE, Daniel D. Stancil, Senior Member (HVAC) ducts in buildings behave as multimode waveguides when excited at radio frequencies and thus, can of a usual indoor propagation channel. In this paper, we describe physical mechanisms which affect the HVAC

Hochberg, Michael

399

ETME 422 -REFRIGERATION & HVAC SYSTEMS FALL 2011 LEC -10:00 -10:50am M W F RH 312  

E-Print Network (OSTI)

10/31/2011 ETME 422 - REFRIGERATION & HVAC SYSTEMS FALL 2011 LEC - 10:00 - 10:50am M W F RH 312 Catalog Description ETME 422 PRINCIPLES OF HVAC I F 3 cr. LEC 3 PREREQUISITE: EMEC 320 or EGEN 324. -- Refrigeration and heating, ventilating and air-conditioning (HVAC) for comfort and industrial applications

Dyer, Bill

400

Predicting of fan speed for energy saving in HVAC system based on adaptive network based fuzzy inference system  

Science Conference Proceedings (OSTI)

In this paper, a HVAC (heating, ventilating and air-conditioning) system has two different zones was designed and fan motor speed to minimize energy consumption of the HVAC system was controlled by a conventional (proportional-integral-derivative) PID ... Keywords: ANFIS, Air flow control, Energy saving, Fan motor speed predicting, HVAC system, PID control, Temperature control

Servet Soyguder; Hasan Alli

2009-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

DEMONSTRATION OF A HYBRID INTELLIGENT CONTROL STRATEGY FOR CRITICAL BUILDING HVAC SYSTEMS  

SciTech Connect

Many industrial facilities utilize pressure control gradients to prevent migration of hazardous species from containment areas to occupied zones, often using Proportional-Integral-Derivative (PID) control. Within these facilities, PID control is often inadequate to maintain desired performance due to changing operating conditions. As the goal of the Heating, Ventilation and Air-Conditioning (HVAC) control system is to optimize the pressure gradients and associated flows for the plant, Linear Quadratic Tracking (LQT) provides a time-based approach to guiding plant interactions. However, LQT methods are susceptible to modeling and measurement errors, and therefore a hybrid design using the integration of soft control methods with hard control methods is developed and demonstrated to account for these errors and nonlinearities.

Craig Rieger; D. Subbaram Naidu

2010-06-01T23:59:59.000Z

402

Development of New HVAC Design Tools: Search for the Holy Grail of  

NLE Websites -- All DOE Office Websites (Extended Search)

Development of New HVAC Design Tools: Search for the Holy Grail of Development of New HVAC Design Tools: Search for the Holy Grail of Ventilation Research Speaker(s): Jelena Srebric Date: January 29, 2004 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: William Fisk HVAC systems are very important to our wellbeing, energy, and the environment. Current design tools are typically supported by basic knowledge, and keep us at arm's length from the many practical problems. The design paradigm has been shifted several times in the past from thermal comfort, energy conservation, health concerns, and now probably to security issues. Each of the shift has required better design tools of HVAC systems.A team led by Dr. Jelena Srebric at the Department of Architecture, the Penn State University (PSU) is developing new HVAC design tools to meet

403

Direct Digital Control- A Tool for Energy Management of HVAC Systems  

E-Print Network (OSTI)

Direct digital control (DDC) applied to heating, ventilating, and air-conditioning (HVAC) systems corrects many of the deficiencies of conventional automatic temperature control systems. By applying new control sequences, DDC optimizes HVAC energy use. DDC can reduce HVAC operation and maintenance time and provide the environmental conditions needed to maximize production. DDC technology uses standalone, microprocessor based controllers. Controllers directly sense and process control variables (e.g. temperature, pressure) and provide a control signal to an actuator. Personal computers provide remote or local access to the digital controllers and give HVAC mechanics, energy managers, and facility engineers capabilities that conventional control systems do not offer. This paper discusses the most common deficiencies of conventionally controlled HVAC systems, advantages of DOC systems, and a case study retrofit from pneumatic control to digital control.

Swanson, K.

1993-03-01T23:59:59.000Z

404

Measuring Advances in HVAC Distribution System Design  

SciTech Connect

Substantial commercial building energy savings have been achieved by improving the performance of the HV AC distribution system. The energy savings result from distribution system design improvements, advanced control capabilities, and use of variable-speed motors. Yet, much of the commercial building stock remains equipped with inefficient systems. Contributing to this is the absence of a definition for distribution system efficiency as well as the analysis methods for quantifying performance. This research investigates the application of performance indices to assess design advancements in commercial building thermal distribution systems. The index definitions are based on a first and second law of thermodynamics analysis of the system. The second law or availability analysis enables the determination of the true efficiency of the system. Availability analysis is a convenient way to make system efficiency comparisons since performance is evaluated relative to an ideal process. A TRNSYS simulation model is developed to analyze the performance of two distribution system types, a constant air volume system and a variable air volume system, that serve one floor of a large office building. Performance indices are calculated using the simulation results to compare the performance of the two systems types in several locations. Changes in index values are compared to changes in plant energy, costs, and carbon emissions to explore the ability of the indices to estimate these quantities.

Franconi, E.

1998-05-01T23:59:59.000Z

405

Microeconomics of the ideal gas like market models  

E-Print Network (OSTI)

We develop a framework based on microeconomic theory from which the ideal gas like market models can be addressed. A kinetic exchange model based on that framework is proposed and its distributional features have been studied by considering its moments. Next, we derive the moments of the CC model (Eur. Phys. J. B 17 (2000) 167) as well. Some precise solutions are obtained which conform with the solutions obtained earlier. Finally, an output market is introduced with global price determination in the model with some necessary modifications.

Chakrabarti, Anindya S

2009-01-01T23:59:59.000Z

406

Calculation of gas hydrate dissociation with finite-element model  

SciTech Connect

In situ gas hydrates have been found abundantly in the Arctic regions of the US, Canada, and Russia. Gas recovery from such a hydrate reservoir under permafrost conditions is described in the present paper. The technique is based upon a finite-element transient heat-conduction model that includes the ability to handle phase change. That model is applied to field data available from the North Slope of Alaska for predicting natural-gas production. Parametric studies have also been conducted to explore the effects of hydrate zone thickness, wellbore temperature, wellbore radius, porosity, etc., on the gas production rate. Comparisons of temperature distributions throughout the medium, and the propagation of the moving dissociation front with respect to time predicted by the present scheme and a finite-difference scheme, show good agreement. The data generated in the present study may be useful in deciding on the most optimal technique for gas recovery from hydrates. Additionally, it may provide drilling engineers with valuable information to establish guidelines for safe drilling in the presence of hydrates.

Das, D.K.; Srivastava, V. (Univ. of Alaska, Fairbanks, AK (United States). Mechanical Engineering Dept.)

1993-12-01T23:59:59.000Z

407

Comparing Price Forecast Accuracy of Natural Gas Models and Futures Markets  

E-Print Network (OSTI)

Update on Petroleum, Natural Gas, Heating Oil and Gasoline.of the Market for Natural Gas Futures. Energy Journal 16 (Modeling Forum. 2003. Natural Gas, Fuel Diversity and North

Wong-Parodi, Gabrielle; Dale, Larry; Lekov, Alex

2005-01-01T23:59:59.000Z

408

Numerical Modeling of Fractured Shale-Gas and Tight-Gas Reservoirs Using Unstructured Grids  

E-Print Network (OSTI)

Various models featuring horizontal wells with multiple induced fractures have been proposed to characterize flow behavior over time in tight gas and shale gas systems. Currently, there is little consensus regarding the effects of non-ideal fracture geometries and coupled primary-secondary fracture interactions on reservoir performance in these unconventional gas reservoirs. This thesis provides a grid construction tool to generate high-resolution unstructured meshes using Voronoi grids, which provides the flexibility required to accurately represent complex geologic domains and fractures in three dimensions. Using these Voronoi grids, the interaction between propped hydraulic fractures and secondary "stress-release" fractures were evaluated. Additionally, various primary fracture configurations were examined, where the fractures may be non-planar or non-orthogonal. For this study, a numerical model was developed to assess the potential performance of tight gas and shale gas reservoirs. These simulations utilized up to a half-million grid-blocks and consider a period of up to 3,000 years in some cases. The aim is to provide very high-definition reference numerical solutions that will exhibit virtually all flow regimes we can expect in these unconventional gas reservoirs. The simulation results are analyzed to identify production signatures and flow regimes using diagnostic plots, and these interpretations are confirmed using pressure maps where useful. The coupled primary-secondary fracture systems with the largest fracture surface areas are shown to give the highest production in the traditional "linear flow" regime (which occurs for very high conductivity vertical fracture cases). The non-ideal hydraulic fracture geometries are shown to yield progressively lower production as the angularity of these fractures increases. Hence, to design optimum fracture completions, we should endeavor to keep the fractures as orthogonal to the horizontal well as possible. This work expands the current understanding of flow behavior in fractured tight-gas and shale-gas systems and may be used to optimize fracture and completion design, to validate analytical models and to facilitate more accurate reserves estimation.

Olorode, Olufemi Morounfopefoluwa

2011-12-01T23:59:59.000Z

409

Thermal storage HVAC system retrofit provides economical air conditioning  

Science Conference Proceedings (OSTI)

This article describes an EMS-controlled HVAC system that meets the ventilation and cooling needs of an 18,000-seat indoor ice hockey arena. The Buffalo Memorial Auditorium (affectionately referred to as the Aud) was built in 1937 under the Works Project Administration of the federal government. Its original configuration included a 12,000-seat arena with an ice skating rink. By the late 1980s, the city was unsuccessfully attempting to attract events and tenants to the auditorium, which lacked air conditioning and other modern amenities. Thus, it was decided to renovate the facility to make it marketable. The first phase of the renovation included installing an air-conditioning system in the arena and repairing the existing building systems that were inoperable because of deferred maintenance. After considering the existing conditions (such as size of the space, intermittent usage, construction restrictions, operating budgets and the limited operations staff), the engineering team designed an innovative HVAC system. The system's features include: a carbon dioxide monitoring device that controls the intake of outside air; an ice storage system that provides chilled water and shifts electrical demand to off-peak hours; and a design that uses the building mass as a heat sink. A new energy management system (EMS) determines building cooling needs based on the type of event, ambient conditions and projected audience size. Then, it selects the most economical method to obtain the desired arena temperature.

Smith, S.F. (Wendel Engineers, P.C., Buffalo, NY (United States))

1993-03-01T23:59:59.000Z

410

Avoiding low frequency noise in packaged HVAC equipment  

Science Conference Proceedings (OSTI)

The purpose of this article is to help those involved in the design and commissioning of packaged HVAC systems to understand the root causes of low frequency noise problems and how to avoid many of them at the design stage. In the 1980's, two things happened to dramatically change the types of noise problems encountered in typical new construction. The first was the introduction of new energy regulations that favored variable air volume (VAV) distribution systems over constant volume air distribution systems. A by-product of VAV design is that mid- and high frequency sound pressure levels produced by current air terminal devices and diffusers in many applications are significantly lower than in the past. The second factor was a trend away from the use of built-up central station fan equipment in favor of packaged, floor-by-floor air handlers or rooftop units. As a result, today's HVAC system noise problems are not confined to just the roar and hiss of the past, but now include intense low frequency rumble and time modulation. Indeed, most current noise problems in modern buildings occur in the frequency range well below 250 Hz. A large fraction of these are a result of the dominant sound pressure levels in the 12 to 40 Hz region. These factors, combined with a substantial increase in the level of low frequency sound from the rest of the system, can produce a non-neutral, time modulated, rumbly sounding background noise that many people find objectionable.

Ebbing, C.E. (Carrier Corp., Syracuse, NY (United States). Commercial Unitary Division); Blazier, W.E.Jr. (Warren Blazier Associates, San Francisco, CA (United States))

1993-06-01T23:59:59.000Z

411

Evaluation of the gas production economics of the gas hydrate cyclic thermal injection model. [Cyclic thermal injection  

SciTech Connect

The objective of the work performed under this directive is to assess whether gas hydrates could potentially be technically and economically recoverable. The technical potential and economics of recovering gas from a representative hydrate reservoir will be established using the cyclic thermal injection model, HYDMOD, appropriately modified for this effort, integrated with economics model for gas production on the North Slope of Alaska, and in the deep offshore Atlantic. The results from this effort are presented in this document. In Section 1, the engineering cost and financial analysis model used in performing the economic analysis of gas production from hydrates -- the Hydrates Gas Economics Model (HGEM) -- is described. Section 2 contains a users guide for HGEM. In Section 3, a preliminary economic assessment of the gas production economics of the gas hydrate cyclic thermal injection model is presented. Section 4 contains a summary critique of existing hydrate gas recovery models. Finally, Section 5 summarizes the model modification made to HYDMOD, the cyclic thermal injection model for hydrate gas recovery, in order to perform this analysis.

Kuuskraa, V.A.; Hammersheimb, E.; Sawyer, W.

1985-05-01T23:59:59.000Z

412

Natural gas production from hydrate dissociation: An axisymmetric model  

Science Conference Proceedings (OSTI)

This paper describes an axisymmetric model for natural gas production from the dissociation of methane hydrate in a confined reservoir by a depressurizing well. During the hydrate dissociation, heat and mass transfer in the reservoir are analyzed. The system of governing equations is solved by a finite difference scheme. For different well pressures and reservoir temperatures, distributions of temperature and pressure in the reservoir, as well as the natural gas production from the well are evaluated. The numerical results are compared with those obtained by a linearization method. It is shown that the gas production rate is a sensitive function of well pressure. The simulation results are compared with the linearization approach and the shortcomings of the earlier approach are discussed.

Ahmadi, G. (Clarkson Univ., Pottsdam, NY); Ji, Chuang (Clarkson Univ., Pottsdam, NY); Smith, D.H.

2007-08-01T23:59:59.000Z

413

Holographic Dark Energy Model with Modified Generalized Chaplygin Gas  

E-Print Network (OSTI)

We present a holographic dark energy model of the universe considering modified generalized Chaplygin gas (GCG). The modified GCG behaves as an ordinary barotropic fluid in the early epoch when the universe was tiny but behaves subsequently as a $\\Lambda$CDM model at late epoch. An equivalent model with scalar field is obtained here by constructing the corresponding potential. The holographic dark energy is identified with the modified GCG and we determine the corresponding holographic dark energy field and its potential. The stability of the holographic dark energy in this case is also discussed.

B. C. Paul; P. Thakur; A. Saha

2007-07-31T23:59:59.000Z

414

Implications of a Regime-Switching Model on Natural Gas Storage Valuation and Optimal Operation  

E-Print Network (OSTI)

Implications of a Regime-Switching Model on Natural Gas Storage Valuation and Optimal Operation-switching model for the risk adjusted natural gas spot price and study the implications of the model on the valuation and optimal operation of natural gas storage facilities. We calibrate the model parameters to both

Forsyth, Peter A.

415

Constrained model predictive control implementation for a heavy-duty gas turbine power plant  

Science Conference Proceedings (OSTI)

In this paper, model predictive control (MPC) strategy is implemented to a GE9001E gas turbine power plant. A linear model is developed for the gas turbine using conventional mathematical models and ARX identification procedure. Also a process control ... Keywords: ARX, PID, gas turbine, identification, modeling, multivariable control, power plant, predictive control

Hadi Ghorbani; Ali Ghaffari; Mehdi Rahnama

2008-06-01T23:59:59.000Z

416

Numerical Early Warning Model Research of Landfill Gas Permeation and Diffusion Considering Flow-Temperature Coupling  

Science Conference Proceedings (OSTI)

Based on seepage mechanics in porous medium gas and heat transfer theory, numerical early warning model is established, which is on quantitative description of migration and release of landfill gas and penetration and diffusion of energy, and dynamic ... Keywords: component, landfill gas, flow-temperature coupling, gas pressure and temperature distribution, numerical early warning model

Xue Qiang; Feng Xia-ting; Ma Shi-jin; Zhou Xiao-jun

2009-10-01T23:59:59.000Z

417

Gas-Liquid Coexistence in the Primitive Model for Water  

E-Print Network (OSTI)

We evaluate the location of the gas-liquid coexistence line and of the associated critical point for the primitive model for water (PMW), introduced by Kolafa and Nezbeda [J. Kolafa and I. Nezbeda, Mol. Phys. 61, 161 (1987)]. Besides being a simple model for a molecular network forming liquid, the PMW is representative of patchy proteins and novel colloidal particles interacting with localized directional short-range attractions. We show that the gas-liquid phase separation is metastable, i.e. it takes place in the region of the phase diagram where the crystal phase is thermodynamically favored, as in the case of articles interacting via short-range attractive spherical potentials. Differently from spherical potentials, we do not observe crystallization close to the critical point. The region of gas-liquid instability of this patchy model is significantly reduced as compared to equivalent models of spherically interacting particles, confirming the possibility of observing kinetic arrest in an homogeneous sample driven by bonding as opposed to packing.

F. Romano; P. Tartaglia; F. Sciortino

2007-03-14T23:59:59.000Z

418

Influence of two dynamic predictive clothing insulation models on building energy performance  

E-Print Network (OSTI)

Energy Consumption, Energy and Buildings, Vol. 26, 283-291.Insulation Models on Building Energy Use, HVAC sizing andClothing Model Impact on Building Energy Performance

Lee, Kwang Ho; Schiavon, Stefano

2013-01-01T23:59:59.000Z

419

Liquid-gas phase transition in a two-components isospin lattice gas model for asymmetric nuclear matter  

E-Print Network (OSTI)

A two-components isospin lattice gas model has been employed to study the liquid-gas phase transition for asymmetric nuclear matter. An additional degree of freedom, namely, the asymmetry parameter alpha has been considered carefully for studying the phase transition. We have shown that under the mean field approximation, the liquid-gas phase transition given by this model is of second order. The entropy continues at the phase transition point. The binodal surface is addressed.

Wei Liang Qian; Ru-Keng Su

2002-10-04T23:59:59.000Z

420

Baltimore Gas and Electric Company (Gas) - Residential Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

(Gas) - Residential Energy (Gas) - Residential Energy Efficiency Rebate Program Baltimore Gas and Electric Company (Gas) - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Ventilation Manufacturing Heating & Cooling Commercial Heating & Cooling Heating Program Info State Maryland Program Type Utility Rebate Program Rebate Amount Gas Furnace: $300 or $400 Duct Sealing: $200 Tune-ups: $100 Installation Rebates: Contact BGE The Baltimore Gas and Electric Company (BGE) offers the Smart Energy Savers Program for residential natural gas customers to improve the energy efficiency of eligible homes. Rebates are available for furnaces, HVAC system tune-ups, and insulation measures. All equipment and installation

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

A physics-based emissions model for aircraft gas turbine combustors  

E-Print Network (OSTI)

In this thesis, a physics-based model of an aircraft gas turbine combustor is developed for predicting NO. and CO emissions. The objective of the model is to predict the emissions of current and potential future gas turbine ...

Allaire, Douglas L

2006-01-01T23:59:59.000Z

422

Application of Various HVAC Simulation Programs and Visual Tools to Commissioning  

E-Print Network (OSTI)

Various existing HVAC system simulation programs and visualization tools are considered to be potentially powerful tools for commissioning. Although not originally developed as commissioning tools, these programs facilitate the confirmation/comparison of HVAC system function and performance and enable detailed analysis of parameters influencing HVAC system performance. This paper investigates the functionality and ease of use of several such programs in support of the commissioning process. The investigation and assessment of simulation programs includes: Micro HASP, Micro ACSS, FACES, LCEM, HVACSIM+, TRNSYS, DOE-2, EnergyPlus and DeST and their visual tools.

Zheng, M.; Pan, S.

2007-01-01T23:59:59.000Z

423

The Natural Gas Market Model: Equations and data sources  

SciTech Connect

In 1981, EIA began a major study of the impact of natural gas deregulation. Through 1981, the major product of that study was the August 1981 EIA analysis paper entitled ''Analysis of Economic Effects of Accelerated Deregulation of Natural Gas Prices.'' That paper will be referred to as the ''Deregulation Study'' below. The Natural Gas Market Model (NGMM) was the primary model used to produce the forecasts discussed in the Deregulation Study. A modified version of NGMM has been used in the initial runs of the EIA Extended Short-term Forecasting System (ESFS), which is still under development. The purpose of this paper is to provide a comprehensive description of what NGMM is, and of the inputs used with NGMM for the Deregulation Study. The Deregulation Study, and the many documentation reports it cites, contain much information about the substantive studies which led up to the forecasts; however, it does not provide enough detail on how these studies were brought together to permit either a replication or an in-depth evaluation of the forecasts. EIA standards require that models be documented in enough detail to permit replication. This report attempts to fill that gap in documentation, on the basis of a line-by-line audit of the model code, interviews with the model developers, and a replication of the model in the user-oriented system Troll. The report mentions the mechanics of how the solutions are obtained, but not in complete detail. 2 figs., 6 tabs.

Werbos, P.J.

1981-11-01T23:59:59.000Z

424

HVAC Right-Sizing Part 1: Calculating Loads  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Building America Building America Presented by: Mike Gestwick - National Renewable Energy Laboratory Arlan Burdick, Anthony Grisolia - IBACOS, a Building America Research Team HVAC Right-Sizing Part 1: Calculating Loads Thursday, April 28 11:00 a.m. - 12:00 p.m. Eastern Building Technologies Program Mike Gestwick michael.gestwick@nrel.gov Building America: Introduction April 28, 2011 Introduction to Building America * Reduce energy use in new and existing residential buildings * Promote building science and systems engineering / integration approach * "Do no harm": Ensure safety, health and durability are maintained or improved * Accelerate adoption of high performance technologies www.buildingamerica.gov 15 Industry Research Teams Habitat Cost Effective Energy Retrofit Program

425

Commercial Building HVAC Energy Usage in Semi-Tropical Climates  

E-Print Network (OSTI)

The design of heating and cooling equipment in semi-tropical climates presents some design considerations and limitations not so prevalent in temperate climates. In some cases, the heating season may be non-existent for all practical purposes. Another consideration is the high ventilation loads due to cooling the moist air prevalent in semi-tropical climates. This paper describes a computer program which assesses all the pertinent variables which comprise the annual heating and cooling energy requirements for commercial buildings. It is then suggested that this computer program would be valuable in determining the changes one could expect in annual energy usage by varying certain building design parameters. Secondly, a small office building actually constructed in Central Florida in which the author designed the Heating and Cooling HVAC system is described. Tradeoffs are presented showing the effects of changes in these building design parameters.

Worbs, H. E.

1987-01-01T23:59:59.000Z

426

Revised noise criteria for design and rating of HVAC systems  

Science Conference Proceedings (OSTI)

This paper reviews current methods of rating the noise produced by HVAC systems and explains why these ratings fail to be correlated with subjective opinion in many cases. An entirely new method of assigning noise ratings is proposed which is expected to provide a significantly better correlation between objective measurements and subjective response. The proposed new rating method makes use of a revised set of noise criterion curves (RC curves) which appeared for the first time in Chap. 35 of the 1980 Systems Volume of the ASHRAE Handbook. This paper also discusses the technical considerations leading to the development of the RC curves as a replacement for the NC curves which have been used in the past.

Warren E. Blazier Jr.

1984-01-01T23:59:59.000Z

427

Co-simulation of innovative integrated HVAC systems in buildings  

SciTech Connect

Integrated performance simulation of buildings HVAC systems can help in reducing energy consumption and increasing occupant comfort. However, no single building performance simulation (BPS) tool offers sufficient capabilities and flexibilities to analyze integrated building systems and to enable rapid prototyping of innovative building and system technologies. One way to alleviate this problem is to use co-simulation, as an integrated approach to simulation. This article elaborates on issues important for co-simulation realization and discusses multiple possibilities to justify the particular approach implemented in the here described co-simulation prototype. The prototype is validated with the results obtained from the traditional simulation approach. It is further used in a proof-of-concept case study to demonstrate the applicability of the method and to highlight its benefits. Stability and accuracy of different coupling strategies are analyzed to give a guideline for the required coupling time step.

Trcka, Marija; Hensena, Jan L.M.; Wetter, Michael

2010-06-21T23:59:59.000Z

428

Occupancy sensors for HVAC gaining in hotel industry  

SciTech Connect

The hotel industry is overcoming its skepticism as occupancy sensors with built-in thermistors to control heating, ventilating, and air conditioning (HVAC) units demonstrate their ability to cut energy costs as much as 30%. Despite the successful demonstrations and acceptance by Holiday Inn, some hotel managers of other chains continue to resist. Occupancy sensors have either ultrasonic or infrared signals, but differ from lighting control devices by also having internal thermistors and remote door switches. This allows the rooms to reach comfort levels only when the guest is present since occupants are only minimally affected if temperatures are modified during unoccupied periods. The system works best for roadside-type motels rather than convention hotels, where occupants are in and out of their rooms.

Ladd, C.

1985-12-02T23:59:59.000Z

429

Impacts of a gas cartel on the European gas market – selected results from the supply model EUGAS  

E-Print Network (OSTI)

b, * This article introduces the simulation model EUGAS which allows a quantitative analysis of the long-term natural gas supply of Europe. Based on chosen parameter specifications, the simulation shows that no discernible physical gas scarcity at least for the next 20-30 years will occur in Europe. Significant investments in new production and transport facilities will be necessary during the next decades. Diversification of supplies and political considerations will have a significant impact on the development of new natural gas resources. Possibly, a new built gas cartel similar to the OPEC may modify the gas supply pattern of Europe.

J. Perner A; A. Seeliger

2003-01-01T23:59:59.000Z

430

Modeling and control of hydronic building HVAC systems.  

E-Print Network (OSTI)

??Energy requirements for heating and cooling of residential, commercial and industrial spaces constitute a major fraction of end use energy consumed. Centralized systems such as… (more)

Chandan, Vikas

2010-01-01T23:59:59.000Z

431

Decentralized model predictive control of a multiple evaporator HVAC system.  

E-Print Network (OSTI)

??Vapor compression cooling systems are the primary method used for refrigeration and air conditioning, and as such are a major component of household and commercial… (more)

Elliott, Matthew Stuart

2009-01-01T23:59:59.000Z

432

MODELING AND SIMULATION OF HVAC FAULTS IN ENERGYPLUS  

E-Print Network (OSTI)

of calibration Chiller Fouled condenser Chiller RefrigerantDecreased chiller efficiency and increased condenser outlettemperature Reduced condenser pressure and compressor

Basarkar, Mangesh

2013-01-01T23:59:59.000Z

433

Building energy modeling programs comparison Research on HVAC...  

NLE Websites -- All DOE Office Websites (Extended Search)

Building energy simulation programs are effective tools for the evaluation of building energy saving and optimization of design. The fact that large discrepancies exist in...

434

Integrated observations and modelling of greenhouse gas budgets at the ecosystem  

E-Print Network (OSTI)

Mitigation KvR 055/12 Integrated observations and modelling of greenhouse gas budgets Nol | Christy van Beek #12;Integrated observations and modelling of greenhouse gas budgets and modelling of greenhouse gas budgets at the ecosystem level in The Netherlands) was carried out

Stoffelen, Ad

435

Modeling of solar receiver for cracking of liquid petroleum gas  

SciTech Connect

The paper presents the model of an industrial solar receiver/reactor for thermal cracking of liquid petroleum gas (LPG) at the typical temperature range of 800--850 C. The concentrated solar radiation enters the receiver located on the ground and provided with a compound parabolic concentrator (CPC) at the ceiling. This is achieved with a reflecting solar tower. The radiative model uses the classical concept of equivalent gray plane to represent a panel of 40 cracking tubes placed in parallel of a refractory wall of the receiver. The radiative flux distribution on each wall is calculated and the chemistry in each reactor tube is evaluated until convergence is achieved. The design of an industrial size receiver, its behavior, and performance have been evaluated using this model. The computer program based on this model was run for a variety of flow conditions, feed compositions, and pressures.

Segal, A.; Epstein, M. [Weizmann Inst. of Science, Rehovot (Israel). Solar Research Facilities Unit

1997-02-01T23:59:59.000Z

436

A dark energy model alternative to generalized Chaplygin gas  

E-Print Network (OSTI)

We propose a new fluid model of dark energy for $-1 \\leq \\omega_{\\text{eff}} \\leq 0$ as an alternative to the generalized Chaplygin gas models. The energy density of dark energy fluid is severely suppressed during barotropic matter dominant epochs, and it dominates the universe evolution only for eras of small redshift. From the perspective of fundamental physics, the fluid is a tachyon field with a scalar potential flatter than that of power-law decelerated expansion. Different from the standard $\\Lambda\\text{CDM}$ model, the suggested dark energy model claims that the cosmic acceleration at present epoch can not continue forever but will cease in the near future and a decelerated cosmic expansion will recover afterwards.

Hova, Hoavo

2010-01-01T23:59:59.000Z

437

Natural gas production problems : solutions, methodologies, and modeling.  

Science Conference Proceedings (OSTI)

Natural gas is a clean fuel that will be the most important domestic energy resource for the first half the 21st centtuy. Ensuring a stable supply is essential for our national energy security. The research we have undertaken will maximize the extractable volume of gas while minimizing the environmental impact of surface disturbances associated with drilling and production. This report describes a methodology for comprehensive evaluation and modeling of the total gas system within a basin focusing on problematic horizontal fluid flow variability. This has been accomplished through extensive use of geophysical, core (rock sample) and outcrop data to interpret and predict directional flow and production trends. Side benefits include reduced environmental impact of drilling due to reduced number of required wells for resource extraction. These results have been accomplished through a cooperative and integrated systems approach involving industry, government, academia and a multi-organizational team within Sandia National Laboratories. Industry has provided essential in-kind support to this project in the forms of extensive core data, production data, maps, seismic data, production analyses, engineering studies, plus equipment and staff for obtaining geophysical data. This approach provides innovative ideas and technologies to bring new resources to market and to reduce the overall environmental impact of drilling. More importantly, the products of this research are not be location specific but can be extended to other areas of gas production throughout the Rocky Mountain area. Thus this project is designed to solve problems associated with natural gas production at developing sites, or at old sites under redevelopment.

Rautman, Christopher Arthur; Herrin, James M.; Cooper, Scott Patrick; Basinski, Paul M. (El Paso Production Company, Houston, TX); Olsson, William Arthur; Arnold, Bill Walter; Broadhead, Ronald F. (New Mexico Bureau of Geology and Mineral Resources, Socorro, NM); Knight, Connie D. (Consulting Geologist, Golden, CO); Keefe, Russell G.; McKinney, Curt (Devon Energy Corporation, Oklahoma City, OK); Holm, Gus (Vermejo Park Ranch, Raton, NM); Holland, John F.; Larson, Rich (Vermejo Park Ranch, Raton, NM); Engler, Thomas W. (New Mexico Institute of Mining and Technology, Socorro, NM); Lorenz, John Clay

2004-10-01T23:59:59.000Z

438

Coupled rock motion and gas flow modeling in blasting  

SciTech Connect

The spherical element computer code DMC (Distinct Motion Code) used to model rock motion resulting from blasting has been enhanced to allow routine computer simulations of bench blasting. The enhancements required for bench blast simulation include: (1) modifying the gas flow portion of DMC, (2) adding a new explosive gas equation of state capability, (3) modifying the porosity calculation, and (4) accounting for blastwell spacing parallel to the face. A parametric study performed with DMC shows logical variation of the face velocity as burden, spacing, blastwell diameter and explosive type are varied. These additions represent a significant advance in the capability of DMC which will not only aid in understanding the physics involved in blasting but will also become a blast design tool. 8 refs., 7 figs., 1 tab.

Preece, D.S. (Sandia National Labs., Albuquerque, NM (United States)); Knudsen, S.D. (RE/SPEC, Inc., Albuquerque, NM (United States))

1991-01-01T23:59:59.000Z

439

Fight Fall Allergies and Save Energy by Checking Your HVAC System |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fight Fall Allergies and Save Energy by Checking Your HVAC System Fight Fall Allergies and Save Energy by Checking Your HVAC System Fight Fall Allergies and Save Energy by Checking Your HVAC System October 15, 2012 - 3:19pm Addthis Change your furnace filter to help keep allergies at bay and keep your furnace and air conditioner running efficiently. | Photo courtesy of ©iStockphoto.com/JaniceRichard. Change your furnace filter to help keep allergies at bay and keep your furnace and air conditioner running efficiently. | Photo courtesy of ©iStockphoto.com/JaniceRichard. Elizabeth Spencer Communicator, National Renewable Energy Laboratory What does this mean for me? Change your furnace filters every month or two to keep your HVAC equipment operating efficiently. I have unbelievably horrible fall allergies. I've never figured out what

440

What are the Best HVAC Solutions for Low-Load, High Performance Homes?"  

Energy.gov (U.S. Department of Energy (DOE))

This presentation was given at the Summer 2012 DOE Building America meeting on July 26, 2012, and addressed the question What are the best HVAC solutions for low-load, high performance homes?"

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Control Systems and Applications for HVAC/R, 1st edition  

Science Conference Proceedings (OSTI)

From the Publisher:Unique in combining into one book, the operational and selection characteristics of commonly used control devices with the thermal and response characteristics of HVAC processes. It presents step-by-step techniques for analyzing the ...

Thomas J. Horan

1996-10-01T23:59:59.000Z

442

Development of New HVAC Design Tools: Search for the Holy Grail...  

NLE Websites -- All DOE Office Websites (Extended Search)

Development of New HVAC Design Tools: Search for the Holy Grail of Ventilation Research Speaker(s): Jelena Srebric Date: January 29, 2004 - 12:00pm Location: Bldg. 90 Seminar Host...

443

ASHRAE sound and vibration technical committee position statement on the use of fiberglass in HVAC systems  

Science Conference Proceedings (OSTI)

Fiberglass duct liner continues to be the most cost?effective solutions to noise control in most HVAC air duct systems. There has been a recent increase in the number of institutional

Russell A. Cooper

1995-01-01T23:59:59.000Z

444

DOE Convening Report on Certification of Commercial HVAC and CRE Products  

Energy.gov (U.S. Department of Energy (DOE))

This document is the convening report on the feasibility of a negotiated rulemaking to revise the certification program for commercial HVAC and CRE products published on October 2, 2012.

445

Applying brain emotional learning algorithm for multivariable control of HVAC systems  

Science Conference Proceedings (OSTI)

In this paper, we apply a modified version of Brain Emotional Learning (BEL) controller for Heating, Ventilating and Air Conditioning (HVAC) control system whose multivariable, nonlinear and non-minimum phase nature makes the task difficult. The proposed ...

N. Sheikholeslami; D. Shahmirzadi; E. Semsar; C. Lucas; M. J. Yazdanpanah

2006-01-01T23:59:59.000Z

446

MODELING AND CONTROL OF A O2/CO2 GAS TURBINE CYCLE FOR CO2 CAPTURE  

E-Print Network (OSTI)

MODELING AND CONTROL OF A O2/CO2 GAS TURBINE CYCLE FOR CO2 CAPTURE Lars Imsland Dagfinn Snarheim and control of a semi-closed O2/CO2 gas turbine cycle for CO2 capture. In the first part the process predictive control, Gas turbines, CO2 capture 1. INTRODUCTION Gas turbines are widely used for power

Foss, Bjarne A.

447

A Hierarchical Rule-Based Fault Detection and Diagnostic Method for HVAC Systems  

E-Print Network (OSTI)

A rule-based, system-level fault detection and diagnostic (FDD) method for HVAC systems was developed. It functions as an interface between multiple, equipment-specific FDD tools and a human operator. The method resolves and prioritizes conflicting fault reports from equipment-specific FDD tools, performs FDD at the system level, and presents an integrated view of an HVAC system’s fault status to an operator. A simulation study to test and evaluate the method was conducted.

Jeffrey Schein; Steven T. Bushby

2005-01-01T23:59:59.000Z

448

DOE Convening Report on Certification of Commercial HVAC and CRE Products  

NLE Websites -- All DOE Office Websites (Extended Search)

Convening Report on Certification of Commercial HVAC and CRE Products, October 2, 2012 Convening Report on Certification of Commercial HVAC and CRE Products, October 2, 2012 1 U.S. DEPARTMENT OF ENERGY CONVENING REPORT ON THE FEASIBILITY OF A NEGOTIATED RULEMAKING TO REVISE THE CERTIFICATION PROGRAM FOR COMMERCIAL HEATING, VENTILATING AIR CONDITIONING AND COMMERCIAL REFRIGERATION EQUIPMENT October 2, 2012 Alan W. Strasser, Esq., MA Convener

449

Gas transport model for chemical vapor infiltration. Topical report  

Science Conference Proceedings (OSTI)

A node-bond percolation model is presented for the gas permeability and pore surface area of the coarse porosity in woven fiber structures during densification by chemical vapor infiltration (CVI). Model parameters include the number of nodes per unit volume and their spatial distribution, and the node and bond radii and their variability. These parameters relate directly to structural features of the weave. Some uncertainty exists in the proper partition of the porosity between {open_quotes}node{close_quotes} and{open_quote}bond{close_quotes} and between intra-tow and inter-tow, although the total is constrained by the known fiber loading in the structure. Applied to cloth layup preforms the model gives good agreement with the limited number of available measurements.

Starr, T.L. [Georgia Institute of Technology, Atlanta, GA (United States). School of Materials Science and Engineering

1995-05-01T23:59:59.000Z

450

Arbitrage free cointegrated models in gas and oil future markets  

E-Print Network (OSTI)

In this article we present a continuous time model for natural gas and crude oil future prices. Its main feature is the possibility to link both energies in the long term and in the short term. For each energy, the future returns are represented as the sum of volatility functions driven by motions. Under the risk neutral probability, the motions of both energies are correlated Brownian motions while under the historical probability, they are cointegrated by a Vectorial Error Correction Model. Our approach is equivalent to defining the market price of risk. This model is free of arbitrage: thus, it can be used for risk management as well for option pricing issues. Calibration on European market data and numerical simulations illustrate well its behavior.

Benmenzer, Grégory; Jérusalem, Céline

2007-01-01T23:59:59.000Z

451

Natural gas transmission and distribution model of the National Energy Modeling System  

SciTech Connect

The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of Integrated Analysis and Forecasting of the Energy Information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. From 1982 through 1993, the Intermediate Future Forecasting System (IFFS) was used by the EIA for its analyses, and the Gas Analysis Modeling System (GAMS) was used within IFFS to represent natural gas markets. Prior to 1982, the Midterm Energy Forecasting System (MEFS), also referred to as the Project Independence Evaluation System (PIES), was employed. NEMS was developed to enhance and update EIA`s modeling capability by internally incorporating models of energy markets that had previously been analyzed off-line. In addition, greater structural detail in NEMS permits the analysis of a broader range of energy issues. The time horizon of NEMS is the midterm period (i.e., through 2015). In order to represent the regional differences in energy markets, the component models of NEMS function at regional levels appropriate for the markets represented, with subsequent aggregation/disaggregation to the Census Division level for reporting purposes.

1997-02-01T23:59:59.000Z

452

Gas-Phase Diffusion in Porous Media: Comparison of Models Stephen W. Webb  

Office of Scientific and Technical Information (OSTI)

Gas-Phase Diffusion in Porous Media: Comparison of Models Gas-Phase Diffusion in Porous Media: Comparison of Models Stephen W. Webb Sandia National Laboratories Albuquerque, New Mexico 87 185 ABSTRACT Two models are commonly used to analyze gas- phase diffusion in porous media in the presence of advection, the Advective-Dispersive Model (ADM) and the Dusty-gas Model (DGM). The ADM, which is used in TOUGH2, is based on a simple linear addition of advection calculated by Darcy's law and ordinary diffusion using Fick's law with a porosity- tortuosity-gas saturation multiplier to account for the porous medium. Another approach for gas-phase transport in porous media is the Dusty-Gas Model. This model applies the kinetic theory of gases to the gaseous components and the porous media (or "dust") to combine transport due to diffusion and

453

Application of RBF-type ARX Modeling and Control to Gas Turbine Combined Cycle SCR Systems  

E-Print Network (OSTI)

Application of RBF-type ARX Modeling and Control to Gas Turbine Combined Cycle SCR Systems Y, nonlinear model-based predictive control, energy saving. 1. INTRODUCTION In Japan, GTCC(Gas Turbine Combined gas-firing GTCC power plant is most effective in terms of thermal efficiency and lower CO2 energy

Ozaki, Tohru

454

Observational Constraints of New Variable Modified Chaplygin Gas Model  

E-Print Network (OSTI)

Assuming the flat FRW universe in Einstein's gravity filled with New Variable Modified Chaplygin gas (NVMCG) dark energy and dark matter having negligible pressure. In this research work we analyze the viability on the basis of recent observation. Hubble parameter $H$ is expressed in terms of the observable parameters $H_0$, $\\Omega_m^0$ and the model parameters $A_0$, $B_0$, $C_0$, $m$, $n$, $\\alpha$ and the red shift parameter $z$. Here we find a best fitted parameter range of $A_0$, $B_0$ keeping $0\\leq \\alpha \\leq 1$ and using Stern data set (12 points) by minimizing the $\\chi^2$ test at 66%, 90% and 99% confidence levels. Next we do the joint analysis with BAO and CMB observations. Again evaluating the distance modulus $\\mu(z)$ vs redshift ($z$) curve obtained in the model NVMCG with dark matter with the best fitted value of the parameters and comparing with that derived from the union2 compilation data.

Jhumpa Bhadra; Ujjal Debnath

2012-11-09T23:59:59.000Z

455

Conserved number fluctuations in a hadron resonance gas model  

E-Print Network (OSTI)

Net-baryon, net-charge and net-strangeness number fluctuations in high energy heavy-ion collisions are discussed within the framework of a hadron resonance gas (HRG) model. Ratios of the conserved number susceptibilities calculated in HRG are being compared to the corresponding experimental measurements to extract information about the freeze-out condition and the phase structure of systems with strong interactions. We emphasize the importance of considering the actual experimental acceptances in terms of kinematics (pseudorapidity ($\\eta$) and transverse momentum ($p_{T}$)), the detected charge state, effect of collective motion of particles in the system and the resonance decay contributions before comparisons are made to the theoretical calculations. In this work, based on HRG model, we report that the net-baryon number fluctuations are least affected by experimental acceptances compared to the net-charge and net-strangeness number fluctuations.

P. Garg; D. K. Mishra; P. K. Netrakanti; B. Mohanty; A. K. Mohanty; B. K. Singh; N. Xu

2013-04-26T23:59:59.000Z

456

State-of-the-art sports facility's HVAC  

SciTech Connect

This article describes the HVAC systems design to keep Cleveland's new Gateway sports and entertainment complex comfortable. This magnificent new facility embraces the 42,000-seat Jacobs Field, with its natural grass playing surface, and the 21,000-seat Arena at Gateway (the official name will be announced at its August 1 opening). The Arena is the new home of the Cleveland Cavaliers NBA basketball team and the Lumberjacks IHL ice hockey team. Other events that will be held here include arena football, circuses, ice shows, and concerts. It is anticipated that the Arena will be in use in excess of 200 days a year for these and other functions. The ballpark and the arena are separated by Gateway Plaza, a large illuminated public space that also will be the site of various entertainment events. An air conditioned pedestrian bridge, approximately 0.7 miles in length, connects the Arena with the Regional Transit Authority's downtown rapid transit station. Other enclosed walkways connect the Arena with two parking garages (3,158 vehicles total) and the larger garage with Jacobs Field.

Horton, M.K. (Gateway Sports Complex, Cleveland, OH (United States))

1994-08-01T23:59:59.000Z

457

Compression effects on pressure loss in flexible HVAC ducts  

SciTech Connect

A study was conducted to evaluate the effect of compression on pressure drop in flexible, spiral wire helix core ducts used in residential and light commercial applications. Ducts of 6 inches, 8 inches and 10 inches (150, 200 and 250 mm) nominal diameters were tested under different compression configurations following ASHRAE Standard 120-1999--Methods of Testing to Determine Flow Resistance of HVAC Air Ducts and Fittings. The results showed that the available published references tend to underestimate the effects of compression. The study demonstrated that moderate compression in flexible ducts, typical of that often seen in field installations, could increase the pressure drop by a factor of four, while further compression could increase the pressure drop by factors close to ten. The results proved that the pressure drop correction factor for compressed ducts cannot be independent of the duct size, as suggested by ASHRAE Fundamentals, and therefore a new relationship was developed for better quantification of the pressure drop in flexible ducts. This study also suggests potential improvements to ASHRAE Standard 120-1999 and provides new data for duct design.

Abushakra, Bass; Walker, Iain S.; Sherman, Max H.

2002-07-01T23:59:59.000Z

458

Evaluation of flow capture techniques for measuring HVAC grilleairflows  

SciTech Connect

This paper discusses the accuracy of commercially available flow hoods for residential applications. Results of laboratory and field tests indicate these hoods can be inadequate to measure airflows in residential systems, and there can be large measurement discrepancies between different flow hoods. The errors are due to poor calibrations, sensitivity of the hoods to grille airflow non-uniformities, and flow changes from added flow resistance. It is possible to obtain reasonable results using some flow hoods if the field tests are carefully done, the grilles are appropriate, and grille location does not restrict flow hood placement. We also evaluated several simple flow capture techniques for measuring grille airflows that could be adopted by the HVAC industry and homeowners as simple diagnostics. These simple techniques can be as accurate as commercially available devices. Our test results also show that current calibration procedures for flow hoods do not account for field application problems. As a result, agencies such as ASHRAE or ASTM need to develop a new standard for flow hood calibration, along with a new measurement standard to address field use of flow capture techniques.

Walker, Iain S.; Wray, Craig P.

2002-11-01T23:59:59.000Z

459

A plug and play framework for an HVAC air handling unit and temperature sensor auto recognition technique.  

E-Print Network (OSTI)

??A plug and play framework for an HVAC air handling unit control system is proposed in this study. This is the foundation and the first… (more)

Zhou, Xiaohui

2010-01-01T23:59:59.000Z

460

Tecniche di apprendimento automatico per la rilevazione di malfunzionamenti in sistemi HVAC: il caso di un refrigeratore di liquido centrifugo.  

E-Print Network (OSTI)

??Malfunzionamenti in sistemi di riscaldamento, ventilazione e aria condizionata (HVAC) possono essere rilevati attraverso sitemi di Fault Detection. Spesso le informazioni riguardanti guasti e anomalie… (more)

Corazzol, Chiara

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Framework combining static optimization, dynamic scheduling and decision analysis applicable to complex primary HVAC&R systems.  

E-Print Network (OSTI)

??The primary objective of this work is to propose a general and computationally efficient methodology for dynamic scheduling and optimal control of primary HVAC&R systems… (more)

Jiang, Wei

2006-01-01T23:59:59.000Z

462

RELIABILITY ANALYSIS OF THE ELECTRICAL POWER DISTRIBUTION SYSTEM TO SELECTED PORTIONS OF THE NUCLEAR HVAC SYSTEM  

Science Conference Proceedings (OSTI)

A design requirement probability of 0.01 or less in a 4-hour period ensures that the nuclear heating, ventilation, and air-conditioning (HVAC) system in the primary confinement areas of the Dry Transfer Facilities (DTFs) and Fuel Handling Facility (FHF) is working during a Category 1 drop event involving commercial spent nuclear fuel (CSNF) assemblies (BSC 2004a , Section 5.1.1.48). This corresponds to an hourly HVAC failure rate of 2.5E-3 per hour or less, which is contributed to by two dominant causes: equipment failure and loss of electrical power. Meeting this minimum threshold ensures that a Category 1 initiating event followed by the failure of HVAC is a Category 2 event sequence. The two causes for the loss of electrical power include the loss of offsite power and the loss of onsite power distribution. Thus, in order to meet the threshold requirement aforementioned, the failure rate of mechanical equipment, loss of offsite power, and loss of onsite power distribution must be less than or equal to 2.5E-3 per hour for the nuclear HVAC system in the primary confinement areas of the DTFs and FHF. The loss of offsite power occurs at a frequency of 1.1E-5 per hour (BSC 2004a, Section 5.1.1.48). The purpose of this analysis is to determine the probability of occurrence of the unavailability of the nuclear HVAC system in the primary confinement areas of the DTFs and FHF due to loss of electrical power. In addition, this analysis provides insights on the contribution to the unavailability of the HVAC system due to equipment failure. The scope of this analysis is limited to finding the frequency of loss of electrical power to the nuclear HVAC system in the primary confinement areas of the DTFs and FHF.

N. Ramirez

2004-12-16T23:59:59.000Z

463

Ammonia concentration modeling based on retained gas sampler data  

Science Conference Proceedings (OSTI)

The vertical ammonia concentration distributions determined by the retained gas sampler (RGS) apparatus were modeled for double-shell tanks (DSTs) AW-101, AN-103, AN-104, and AN-105 and single-shell tanks (SSTs) A-101, S-106, and U-103. One the vertical transport of ammonia in the tanks were used for the modeling. Transport in the non-convective settled solids and floating solids layers is assumed to occur primarily via some type of diffusion process, while transport in the convective liquid layers is incorporated into the model via mass transfer coefficients based on empirical correlations. Mass transfer between the top of the waste and the tank headspace and the effects of ventilation of the headspace are also included in the models. The resulting models contain a large number of parameters, but many of them can be determined from known properties of the waste configuration or can be estimated within reasonable bounds from data on the waste samples themselves. The models are used to extract effective diffusion coefficients for transport in the nonconvective layers based on the measured values of ammonia from the RGS apparatus. The modeling indicates that the higher concentrations of ammonia seen in bubbles trapped inside the waste relative to the ammonia concentrations in the tank headspace can be explained by a combination of slow transport of ammonia via diffusion in the nonconvective layers and ventilation of the tank headspace by either passive or active means. Slow transport by diffusion causes a higher concentration of ammonia to build up deep within the waste until the concentration gradients between the interior and top of the waste are sufficient to allow ammonia to escape at the same rate at which it is being generated in the waste.

Terrones, G.; Palmer, B.J.; Cuta, J.M.

1997-09-01T23:59:59.000Z

464

EIA - The National Energy Modeling System: An Overview 2003-Oil and Gas  

Gasoline and Diesel Fuel Update (EIA)

Oil and Gas Supply Module Oil and Gas Supply Module The National Energy Modeling System: An Overview 2003 Oil and Gas Supply Module The oil and gas supply module (OGSM) consists of a series of process submodules that project the availability of: Domestic crude oil production and dry natural gas production from onshore, offshore, and Alaskan reservoirs Imported pipeline–quality gas from Mexico and Canada Imported liquefied natural gas. Figure 12. Oil and Gas Supply Module Regions. Need help, contact the National Energy Information Center at 202-202-586-8800. Figure 13. Oil and Gas Suppply Module Structure. Need help, contact the National Energy Information Center at 202-586-8800. Oil and Gas Supply Module Table. Need help, contact the National Energy Information Center at 202-586-8800.

465

Critical Feynman-Wilson gas: A model for multiparticle physics  

SciTech Connect

We develop a model in which hadron production in the true asymptotic region proceeds via the exchange of a factorizable singularity at J = 1, which implies a sensible meson spectrum. The rise of the hadronic total cross section and the inclusive plateau are ascribed to threshold effects of this mechanism, which is estimated to take effect at Fermilab energies. In the true asymptotic region the total cross section decreases like a small power of the rapidity, while fireball structure appears in the one-particle distribution. Both the exclusive (multiperipheral) and inclusive (Mueller) approaches are exploited. The discussion is in the language of statistical mechanics and our key assumptions are (i) existence of sensible thermodynamic limit, (ii) Koba-Nielsen-Olesen scaling, and (iii) factorization. We show that the nearest-neighbour interaction implied in the Feynman-Wilson ''gas'' by our factorizable singularity is responsible for its critical behaviour at infinite rapidity.

Antoniou, N.G.; Vlassopulos, S.D.P.

1978-12-01T23:59:59.000Z

466

System Modeling of Gas Engine Driven Heat Pump  

SciTech Connect

To improve the system performance of the GHP, modeling and experimental study has been made by using desiccant system in cooling operation (particularly in high humidity operations) and suction line waste heat recovery to augment heating capacity and efficiency. The performance of overall GHP system has been simulated by using ORNL Modulating Heat Pump Design Software, which is used to predict steady-state heating and cooling performance of variable-speed vapor compression air-to-air heat pumps for a wide range of operational variables. The modeling includes: (1) GHP cycle without any performance improvements (suction liquid heat exchange and heat recovery) as a baseline (both in cooling and heating mode), (2) the GHP cycle in cooling mode with desiccant system regenerated by waste heat from engine incorporated, (3) GHP cycle in heating mode with heat recovery (recovered heat from engine). According to the system modeling results, by using desiccant system regenerated by waste heat from engine, the SHR can be lowered to 40%. The waste heat of the gas engine can boost the space heating efficiency by 25% in rated operating conditions.

Mahderekal, Isaac [Oak Ridge National Laboratory (ORNL); Shen, Bo [ORNL; Vineyard, Edward [Oak Ridge National Laboratory (ORNL)

2012-01-01T23:59:59.000Z

467

The National Energy Modeling System: An Overview 2000 - Natural Gas  

Gasoline and Diesel Fuel Update (EIA)

natural gas transmission and distribution module (NGTDM) of NEMS represents the natural gas market and determines regional market-clearing prices for natural gas supplies and for end-use consumption, given the information passed from other NEMS modules. A transmission and distribution network (Figure 15), composed of nodes and arcs, is used to simulate the interregional flow and pricing of gas in the contiguous United States and Canada in both the peak (December through March) and offpeak (April through November) period. This network is a simplified representation of the physical natural gas pipeline system and establishes the possible interregional flows and associated prices as gas moves from supply sources to end users. natural gas transmission and distribution module (NGTDM) of NEMS represents the natural gas market and determines regional market-clearing prices for natural gas supplies and for end-use consumption, given the information passed from other NEMS modules. A transmission and distribution network (Figure 15), composed of nodes and arcs, is used to simulate the interregional flow and pricing of gas in the contiguous United States and Canada in both the peak (December through March) and offpeak (April through November) period. This network is a simplified representation of the physical natural gas pipeline system and establishes the possible interregional flows and associated prices as gas moves from supply sources to end users. Figure 15. Natural Gas Transmission and Distribution Module Network

468

BFRL: HVAC&R - MEMS Refrigerant Expansion Valve  

Science Conference Proceedings (OSTI)

... Replacement Status (in Russian), Journal of ... and Food Technologies, Russia February, 2008. ... on Gasoline, Compressed Natural Gas and Propane. ...

469

Modeling Gas Transport in the Shallow Subsurface During the ZERT CO2 Release Test  

E-Print Network (OSTI)

Research Forum (PERF) Dense Gas Dispersion Modeling Project,Atmospheric dispersion of dense gases, Ann. Rev. Fluidgas (LNG) terminals and transport, and emphasize atmospheric dispersion

Oldenburg, Curtis M.

2009-01-01T23:59:59.000Z

470

Gas generation and bubble formation model for crystalline silicotitanate ion exchange columns  

SciTech Connect

The authors developed a transient model to describe the process of gas generation due to radiolysis and bubble formation in crystalline silicotitanate (CST) ion exchange (IX) columns using the Aspen Custom Modeler (ACM) software package. The model calculates gas concentrations and onset of bubble formation for large CST IX columns. The calculations include cesium loading as a function of time, gas generation as a function of cesium loading, and bubble formation as a function of gas solubility. This report summarizes the model development and predictions.

Hang, T.

2000-07-19T23:59:59.000Z

471

A model for stratified gas-liquid turbulent flow in ducts of arbitrary cross-section  

E-Print Network (OSTI)

93 A model for stratified gas-liquid turbulent flow in ducts of arbitrary cross-section J. M the pressure gradient and the liquid fraction in two-phase gas- liquid fully developed stratified flow.60 Nomenclature. - TWO-PHASE VARIABLES. Definition densities statistical average (gas, liquid) mass average phase

Paris-Sud XI, Université de

472

The Hybrid Solid Oxide Fuel Cell (SOFC) and Gas Turbine (GT) Systems Steady State Modeling  

E-Print Network (OSTI)

The Hybrid Solid Oxide Fuel Cell (SOFC) and Gas Turbine (GT) Systems Steady State Modeling Penyarat plants offer high cycle efficiencies. In this work a hybrid solid oxide fuel cell and gas turbine power, Gas turbine, Hybrid, Solid Oxide Fuel Cell hal-00703135,version1-31May2012 Author manuscript

Paris-Sud XI, Université de

473

A Mixed Complementarity-Based Equilibrium Model of Natural Gas Markets  

Science Conference Proceedings (OSTI)

We present a new multiseasonal, multiyear, natural gas market equilibrium model based on the concept of a competitive equilibrium involving the market participants: producers, storage reservoir operators, peak gas operators, pipeline operators, marketers, ... Keywords: games/group decisions: noncooperative, industries: petroleum/natural gas, marketing: competitive strategy, natural resources: energy, programming: complementarity

Steven A. Gabriel; Supat Kiet; Jifang Zhuang

2005-09-01T23:59:59.000Z

474

Hybrid modeling of industrial energy consumption and greenhouse gas emissions with an application to Canada  

E-Print Network (OSTI)

Hybrid modeling of industrial energy consumption and greenhouse gas emissions with an application explore the implications for Canada's industrial sector of an economy-wide, compulsory greenhouse gas of these strengths is linked to challenges when it comes to forecasting the impact of greenhouse gas policy. We

475

Field validation of the DNDC model for greenhouse gas emissions in East Asian cropping systems  

E-Print Network (OSTI)

Field validation of the DNDC model for greenhouse gas emissions in East Asian cropping systems annual variations of greenhouse gas emissions from cropping systems and effects of land management a powerful tool for estimating greenhouse gas emissions from terrestrial ecosystems. INDEX TERMS: 1610 Global

476

Metro Environmental: The impact of training HVAC technicians using the SightPros-VirTechs system for remote, wireless, Internet video assistance.  

E-Print Network (OSTI)

??This qualitative study explored the overall impact of training HVAC technicians using the SightPros-VirTechs system for remote, wireless, internet video assistance at a small HVAC… (more)

Daily, Ellen Wilmoth Matthews

2008-01-01T23:59:59.000Z

477

Kinetic Model of Gas Bubble Dissolution in Groundwater and Its  

E-Print Network (OSTI)

appear to be more important for the composition of the gas excess than the differences between molecular in both natural and technical gas exchange processes. In chemical engineering systems, the dissolution that the composition of the excess gas does not correspond to atmospheric air (8). Excess air and its fractionation

Aeschbach-Hertig, Werner

478

Grain Boundary Percolation Modeling of Fission Gas Release in Oxide Fuels  

Science Conference Proceedings (OSTI)

We present a new approach to fission gas release modeling in oxide fuels based on grain boundary network percolation. The method accounts for variability in the bubble growth and coalescence rates on individual grain boundaries, and the resulting effect on macroscopic fission gas release. Two-dimensional representa- tions of fuel pellet microstructures are considered, and the resulting gas release rates are compared with traditional two-stage Booth models, which do not account for long-range percolation on grain boundary net- works. The results show that the requirement of percolation of saturated grain boundaries can considerably reduce the total gas release rates, particularly when gas resolution is considered.

Paul C. Millett; Michael R. Tonks; S. B. Biner

2012-05-01T23:59:59.000Z

479

EIA - The National Energy Modeling System: An Overview 2003-Natural Gas  

Gasoline and Diesel Fuel Update (EIA)

Natural Gas Transmission and Distribution Module Natural Gas Transmission and Distribution Module The National Energy Modeling System: An Overview 2003 Natural Gas Transmission and Distribution Module Figure 15. Natural Gas Transmission and Distribution Module Structure. Need help, contact the National Energy Information Center at 202-586-8800. Figure 16. Natural Gas Transmission and distribution Module Network. Need help, contact the National Energy Information Center at 202-586-8800. Natural Gas Transmission and distribution Module Table. Need help, contact the National Energy Information Center at 202-586-8800. The natural gas transmission and distribution module (NGTDM) of NEMS represents the natural gas market and determines regional market–clearing prices for natural gas supplies and for end–use consumption, given the

480

Overview of Avista GHG Modeling NPCC Greenhouse Gas and the Regional Power System Conference  

E-Print Network (OSTI)

6/5/2013 1 Overview of Avista GHG Modeling NPCC Greenhouse Gas and the Regional Power System Natural Gas CO2 Emissions A Bridge to a Low Carbon Future, or the Future? 815 1,190 lbs/MWh Gas CCCT has ~35% of coal emissions on a per-MWh basis Gas CT has ~50% of coal emissions on a per-MWh basis 119 119

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions for  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Critical Question #4: What are the Best Off-the-Shelf HVAC Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions for Low-Load, High-Performance Homes and Apartments? Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions for Low-Load, High-Performance Homes and Apartments? What is currently in the market? What are the limitations of these systems? What are the desired specifications for these systems? What are the realistic space conditioning loads of these high-performance homes and apartments? cq4_forced_air_systems_walker.pdf cq4_simplified_space_cond_prahl.pdf cq4_ground_heat_exchanger_im.pdf More Documents & Publications Track C - Market-Driven Research Solutions Track B - Critical Guidance for Peak Performance Homes Energy Storage & Power Electronics 2008 Peer Review - Power Electronics

482

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

483

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

484

On the capacity limits of hvac duct channel for high-speed internet access  

E-Print Network (OSTI)

Abstract—In this paper, we report theoretical and experimental channel-capacity estimates of heating, ventilation, and air conditioning (HVAC) ducts based on multicarrier transmission that uses-ary quadrature amplitude modulation and measured channel responses at the 2.4-GHz industrial, scientific, and medical band. It is shown theoretically that data rates in excess of 1 Gb/s are possible over distances up to 500 m in straight ducts in which reflections have been suppressed. Our experimental results also show that even in the case of more complex HVAC duct networks (i.e., HVAC duct networks that include bends, tees, etc.) data rates over 2 Gb/s are possible. Our estimations in this case are valid for distances of up to 22 m, which was the maximum distance of our experimental setup. These experimental results, measured with a large-scale testbed set

Ariton E. Xhafa; Ozan K. Tonguz; Ahmet G. Cepni; Student Member; Daniel D. Stancil; Pavel V. Nikitin; Dagfin Brodtkorb

2005-01-01T23:59:59.000Z

485

A practical model to predict gas hydrate formation, dissociation and transportability in oil and gas flowlines.  

E-Print Network (OSTI)

??The oil and gas industry is facing very challenging production issues with offshore explorations in deeper and colder waters. Longer subsea tiebacks will be required… (more)

Zerpa, Luis Eduardo

2013-01-01T23:59:59.000Z

486

High-Speed Internet Access via HVAC Ducts: A New Approach Daniel D. Stancil, Ozan K. Tonguz, Ariton Xhafa, Ahmet Cepni, and Pavel Nikitin  

E-Print Network (OSTI)

High-Speed Internet Access via HVAC Ducts: A New Approach Daniel D. Stancil, Ozan K. Tonguz, Ariton conditioning (HVAC) ducts for indoor wireless transmission systems and networks. Mea- surements and system to 100 Mbps should be possible, when HVAC system is used in con- junction with OFDM technology. Keywords

Stancil, Daniel D.

487

An Application of State-Of-The-Art HVAC and Building Systems  

E-Print Network (OSTI)

This case study describes the successful application of state-of-the-art HVAC and building systems at a large commercial office and industrial facility. The facility's exterior envelope systems, HVAC systems, lighting systems, energy conservation systems, exhaust/heat recovery/make-up air systems, water cooling systems, compressed air systems, electrical distribution systems, water heating systems, and other systems and measures taken are each discussed in detail. The important role that energy engineering played in the overall planning, design, and management of the project is given particular emphasis. Also, the engineering strategies used to integrate energy efficiency, performance optimization, current technology, and cost effectiveness are underscored throughout.

Fiorino, D. P.

1988-09-01T23:59:59.000Z

488

Implications of a Regime-Switching Model on Natural Gas Storage Valuation and Optimal Operation  

E-Print Network (OSTI)

In this paper, we propose a one-factor regime-switching model for the risk adjusted natural gas spot price and study the implications of the model on the valuation and optimal operation of natural gas storage facilities. We calibrate the model parameters to both market futures and options on futures. Calibration results indicate that the regime-switching model is a better fit to market data compared to a one-factor mean-reverting model similar to those used by other authors to value gas storage. We extend a semi-Lagrangian timestepping scheme from Chen and Forsyth (2007) to solve the gas storage pricing problem, essentially a stochastic control problem, and conduct a convergence analysis of the scheme. Numerical results also indicate that the regime-switching model can generate operational strategies for gas storage facilities that reflect the existence of multiple regimes in the market as well as the regime shifts due to various exogenous events.

Zhuliang Chen; Peter A. Forsyth

2007-01-01T23:59:59.000Z

489

An Algorithm for Identification of Reduced-Order Dynamic Models of Gas Turbines  

Science Conference Proceedings (OSTI)

Model based approaches show a lot of advantages for fault detection and condition monitoring. Particularly, it is true in employing reduced order models for real-time parameter identification and output prediction of gas turbines. Many algorithms have ...

Xuewu Dai; Tim Breikin; Hong Wang

2006-08-01T23:59:59.000Z

490

A Coupled CFD-Thermodynamic-Kinetic Model to Simulate a Gas ...  

Science Conference Proceedings (OSTI)

For this purpose, argon gas stirring is commonly used. ... Modeling of Solidification Benchmark of Sn-3% Pb Wt. Alloy under Natural Convection ... CFD Model for Prediction of Liquid Steel Temperature in Ladle during Steel Making and Casting.

491

Implications of a Regime-Switching Model on Natural Gas Storage Valuation and Optimal Operation  

E-Print Network (OSTI)

approximate the seasonality trend in the futures price data. Meanwhile, the table reveals a strong annual-switching model for the risk adjusted natural gas spot price and study the implications of the model) to solve the gas storage pricing problem, essentially a stochastic control problem, and conduct

Forsyth, Peter A.

492

Gas heat pumps are coming: But by a different name  

SciTech Connect

Gas heat pumps are coming, but by a different name. The manufacturers have elected not to call these products {open_quote}heat pumps{close_quotes} because advertising by gas distributors has been so effective at associating the term {open_quote}air-source heat pump{close_quotes} with cold blowing air. Nonetheless, gas-fired air-source heat pumps of the engine-driven and absorption types will be marketed starting in 1994 and in 1997, respectively, according to current plans. This paper identifies the generic participants that have been and will be involved in the gas heat pump deployment effort, and it reviews the underlying forces that caused (or likely will cause) those participants to act as they do. The participants include technology developers; the heating, ventilation, and air-conditioning (HVAC) industry; the utility industry; and state utility regulators. The driving forces include the drifting of unitary HVAC products toward a commodity-like status, the decline of the domestic component of global HVAC markets, the restructuring of the HVAC and gas utility industries, the anticipated restructuring of the electric utility industry, the strengths and weaknesses of gas distributors, and state utility regulation. Also reviewed are technology status, manufacturer commitments, and timetables for introducing products. The road to widespread domestic market acceptance of gas heat pumps will likely be very different from that experienced by electric heat pump manufacturers in the 1950s and 1960s.

Hughes, P.J.

1994-09-01T23:59:59.000Z

493

Mixed Integer Model Predictive Control of Multiple Shale Gas Wells.  

E-Print Network (OSTI)

?? Horizontal wells with multistage hydraulic fracturing are today the most important drilling technology for shale gas extraction. Considered unprofitable before, the production has now… (more)

Nordsveen, Espen T

2012-01-01T23:59:59.000Z

494

Gas turbine combustion modeling for a Parametric Emissions Monitoring System.  

E-Print Network (OSTI)

??Oxides of nitrogen (NOx), carbon monoxide (CO) and other combustion by-products of gas turbines have long been identified as harmful atmospheric pollutants to the environment… (more)

Honegger, Ueli

2007-01-01T23:59:59.000Z

495

Modeling Of Hydraulic Fracture Network Propagation In Shale Gas Reservoirs.  

E-Print Network (OSTI)

??The most effective method for stimulating shale gas reservoirs is massive hydraulic fracture treatments. Recent fracture diagnostic technologies such as microseismic technology have shown that… (more)

Ahn, Chong

2012-01-01T23:59:59.000Z

496

Numerical Modeling of Gas Recovery from Methane Hydrate Reservoirs.  

E-Print Network (OSTI)

??ABSTRACTClass 1 hydrate deposits are characterized by a hydrate bearing layer underlain by a two phase, free-gas and water, zone. A Class 1 hydrate reservoir… (more)

Silpngarmlert, Suntichai

2007-01-01T23:59:59.000Z

497

Modeling Injection and Ignition in Direct Injection Natural Gas Engines.  

E-Print Network (OSTI)

??With increasing concerns about the harmful effects of conventional liquid fossil fuel emissions, natural gas has become a very attractive alternative fuel to power prime… (more)

Cheng, Xu Jr.

2008-01-01T23:59:59.000Z

498

The Polyakov loop and the hadron resonance gas model  

E-Print Network (OSTI)

The Polyakov loop has been used repeatedly as an order parameter in the deconfinement phase transition in QCD. We argue that, in the confined phase, its expectation value can be represented in terms of hadronic states, similarly to the hadron resonance gas model for the pressure. Specifically, L(T) \\approx 1/2\\sum_\\alpha g_\\alpha e^(-\\Delta_\\alpha/T), where g_\\alpha are the degeneracies and \\Delta_\\alpha are the masses of hadrons with exactly one heavy quark (the mass of the heavy quark itself being subtracted). We show that this approximate sum rule gives a fair description of available lattice data with N_f=2+1 at low temperatures by using the spectrum of hadrons containing one charmed quark, and the \\bar{MS}-scheme charmed quark mass. A direct fit to this latter quantity yields a close value, m_c=1280_{-44}^{+29}MeV. The lattice data are well reproduced by a simplified version of this formula, L(T)= N_f(2N_f+3)e^(-\\Delta/T), for T < 200 MeV and Delta=913(2)MeV. We argue that this number should be Delta ...

Megias, E; Salcedo, L L

2012-01-01T23:59:59.000Z

499

Steady-state model for estimating gas production from underground coal gasification  

Science Conference Proceedings (OSTI)

A pseudo-one-dimensional channel model has been developed to estimate gas production from underground coal gasification. The model incorporates a zero-dimensional steady-state cavity growth submodel and models mass transfer from the bulk gas to the coal wall using a correlation for natural convection. Simulations with the model reveal that the gas calorific value is sensitive to coal reactivity and the exposed reactive surface area per unit volume in the channel. A comparison of model results with several small-scale field trials conducted at Centralia in the U.S.A. show that the model can make good predictions of the gas production and composition under a range of different operating conditions, including operation with air and steam/oxygen mixtures. Further work is required to determine whether the model formulation is also suitable for simulating large-scale underground coal gasification field trials.

Greg Perkins; Veena Sahajwalla [University of New South Wales, Sydney, NSW (Australia). School of Materials Science and Engineering

2008-11-15T23:59:59.000Z

500

A Game-Dynamic Model of Gas Transportation Routes and Its Application . . .  

E-Print Network (OSTI)

The purpose of this paper is to study an optimal structure of a system of international gas pipelines competing for a gas market. We develop a game-dynamic model of the operation of several interacting gas pipeline projects with project owners acting as players in the game. The model treats the projects' commercialization times as major players' controls. Current quantities of gas supply are modeled as approximations to Nash equilibrium points in instantaneous "gas supply games", in which each player maximizes his/her current netprofit due to the sales of gas. We use the model to analyze the Turkish gas market, on which gas routes originating from Russia, Turkmenistan and Iran are competing. The analysis is carried out in three steps. At step 1, we model the operation of the pipelines as planned and estimate the associated profits. At step 2, we optimize individual projects, with respect to their profits, assuming that the other pipelines operate as planned. At step 3, we find numerical Nash equilibrium commercialization policies for the entire group of the pipelines. The simulations show the degrees to which the planned regimes are not optimal compared to the Nash equilibrium ones. Another observation is that in equilibrium regimes the pipelines are not always being run at their full capacities, which implies that the proposed pipeline capacities might not be optimal. The simulation results turn out to be moderately sensitive to changes in the discount rate and highly sensitive to changes in the price elasticity of gas demand.

Ger Klaassen; Ivan Matrosov; Alexander Roehrl; Alexander Tarasyev; Arkadii Kryazhimskii