Powered by Deep Web Technologies
Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

MODELING PARTICLE DEPOSITION ON HVAC HEAT EXCHANGERS  

E-Print Network (OSTI)

LBNL-49339 MODELING PARTICLE DEPOSITION ON HVAC HEAT EXCHANGERS J.A. Siegel1,3 * and W.W. Nazaroff2 Department of Energy under contract DE-AC03-76SF00098. #12;MODELING PARTICLE DEPOSITION ON HVAC HEAT, such as discontinuities in the fins, are hypothesized to be responsible for the discrepancy. INDEX TERMS HVAC, Fouling

2

Adaptive HVAC zone modeling for sustainable buildings  

Science Journals Connector (OSTI)

Control of energy flows within a building is critical to achieving optimal performance of heating, ventilation and air-conditioning (HVAC) systems. To design optimal HVAC control strategies, a dynamic model of the HVAC system – particularly the building zones that it services – is essential. As analysis of building energy consumption is facilitated by the accurate prediction of indoor environmental conditions, techniques that dynamically model HVAC zones are crucial, and as such, is an active area of research. This paper focuses on real-time HVAC zone model fitting and prediction techniques based on physical principles, as well as the use of genetic algorithms for optimization. The proposed approach is validated by comparing real-time HVAC zone model fitting and prediction against the corresponding experimental measurements. In addition, comparison with prediction results using an algorithm based on feedback-delayed Kalman filters has demonstrated the superiority of the proposed approach in terms of prediction accuracy.

Glenn Platt; Jiaming Li; Ronxin Li; Geoff Poulton; Geoff James; Josh Wall

2010-01-01T23:59:59.000Z

3

Modeling and optimization of building HVAC systems.  

E-Print Network (OSTI)

??This thesis presents the development of hybrid modeling methodologies for HVAC component static/steady-state models and dynamic/transient models, and the development and implementation of a model-based… (more)

Jin, Guang Yu.

2012-01-01T23:59:59.000Z

4

BS-8: HVAC Modeling and Simulation  

NLE Websites -- All DOE Office Websites (Extended Search)

BS-8: HVAC Modeling and Simulation BS-8: HVAC Modeling and Simulation Speaker(s): Darko Sucic Date: December 5, 2001 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Satkartar K. Kinney Industry Foundation Classes (IFC), an object data model of buildings, are being developed by the International Alliance for Interoperability (IAI) to support data sharing and exchange in the building and construction industry. The IAI, founded in 1995, has published four releases of IFC so far. Several prototype implementations by leading software companies show that commercial IFC software is beginning to meet end user expectations of interoperability in the industry. BS-8 is an LBNL project that started last summer. It is developing the IFC HVAC extension schemata that will extend the IFC object data model and support the exchange of HVAC information

5

Review of modeling methods for HVAC systems  

Science Journals Connector (OSTI)

Abstract This work presents the literature review of the methods used to model the heating, ventilation, and air conditioning (HVAC) systems. The model development is necessary for the study of the energy consumption of HVAC systems. Models are also required to simulate the different supervisory and local loop control strategies to improve the energy consumption efficiency. HVAC systems have complex structures consisting of heat and mass transfer equipment such as chiller, boiler, heating/cooling coils, and supply air ducts. HVAC systems also consist of several sensors and controllers for regulating the controllable variables such as zone temperature, supply air temperature, supply air fan speed, duct static pressure, and chilled water temperature at their set-points. To predict the energy consumption by the HVAC systems accurately, one needs to model the individual components either from the measured data or based on the knowledge of the underlying physical phenomenon. This results in three broad classes of the models known as data driven, physics based, and grey box models. In this paper, major data driven, physics based, and grey box modeling techniques reported in the recent literature are reviewed.

Abdul Afram; Farrokh Janabi-Sharifi

2014-01-01T23:59:59.000Z

6

Modeling and simulation of HVAC Results in EnergyPlus  

E-Print Network (OSTI)

LBNL-5564E Modeling and simulation of HVAC Results in EnergyPlus Mangesh Basarkar, Xiufeng Pang;MODELING AND SIMULATION OF HVAC FAULTS IN ENERGYPLUS Mangesh Basarkar, Xiufeng Pang, Liping Wang, Philip not capture the significant impact of installation, operational and degradation HVAC system faults on actual

7

Modeling Building Thermal Response to HVAC Zoning Virginia Smith  

E-Print Network (OSTI)

Modeling Building Thermal Response to HVAC Zoning Virginia Smith Department of Computer Science HVAC systems account for 38% of building energy usage. Studies have indicated at least 5-15% waste due to unoccu- pied spaces being conditioned. Our goal is to minimize this waste by retrofitting HVAC systems

Whitehouse, Kamin

8

Electric, Gas, and Electric/Gas Energy Options for Cold-Air HVAC Systems  

E-Print Network (OSTI)

An important aspect of the design of cost-effective HVAC systems today is (a) sensitivity to the cost impact of the interplay of utility demand charges, time-of-day rates, gas rates, and gas/electric utility incentive programs vis-à-vis HVAC system...

Meckler, G.

1989-01-01T23:59:59.000Z

9

Modeling and Identification for HVAC Systems.  

E-Print Network (OSTI)

?? Heating, Ventilation and Air Conditioning (HVAC) systems consist of all the equipment that control the conditions and distribution of indoor air. Indoor air must… (more)

Scotton, Francesco

2012-01-01T23:59:59.000Z

10

Thermal model of solar absorption HVAC systems  

SciTech Connect

This paper presents a thermal model that describes the performance of solar absorption HVAC systems. The model considers the collector array, the building cooling and heating loads, the absorption chiller and the high temperature storage. Heat losses from the storage tank and piping are included in the model. All of the results presented in the paper are for an array of flat plate solar collectors with black chrome (selective surface) absorber plates. The collector efficiency equation is used to calculate the useful heat output from the array. The storage is modeled as a non-stratified tank with polyurethane foam insulation. The system is assumed to operate continuously providing air conditioning during the cooling season, space heating during the winter and hot water throughout the year. The amount of heat required to drive the chiller is determined from the coefficient of performance of the absorption cycle. Results are presented for a typical COP of 0.7. The cooling capacity of the chiller is a function of storage (generator) temperature. The nominal value is 190 F (88 C) and the range of values considered is 180 F (82 C) to 210 F (99 C). Typical building cooling and heating loads are determined as a function of ambient conditions. Performance results are presented for Sacramento, CA and Washington, D.C. The model described in the paper makes use of National Solar Radiation Data Base (NSRDB) data and results are presented for these two locations. The uncertainties in the NSRDB are estimated to be in a range of 6% to 9%. This is a significant improvement over previously available data. The model makes it possible to predict the performance of solar HVAC systems and calculate quantities such as solar fraction, storage temperature, heat losses and parasitic power for every hour of the period for which data are available.

Bergquam, J.B.; Brezner, J.M. [California State Univ., Sacramento, CA (United States). Dept. of Mechanical Engineering; [Bergquam Energy Systems, Sacramento, CA (United States)

1995-11-01T23:59:59.000Z

11

Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1  

E-Print Network (OSTI)

Imports/Exports Gas Availability Change efficiency choice equation Add technologiestoHVAC model Adjust cost-efficiency parameter Develop HVAC Conversion

Johnson, F.X.

2010-01-01T23:59:59.000Z

12

Building energy modeling programs comparison Research on HVAC systems  

NLE Websites -- All DOE Office Websites (Extended Search)

energy modeling programs comparison Research on HVAC systems energy modeling programs comparison Research on HVAC systems simulation part Title Building energy modeling programs comparison Research on HVAC systems simulation part Publication Type Journal Year of Publication 2013 Authors Zhou, Xin, Da Yan, Tianzhen Hong, and Dandan Zhu Keywords Building energy modeling programs, comparison tests, HVAC system simulation, theory analysis Abstract Building energy simulation programs are effective tools for the evaluation of building energy saving and optimization of design. The fact that large discrepancies exist in simulated results when different BEMPs are used to model the same building has caused wide concern. Urgent research is needed to identify the main elements that contribute towards the simulation results. This technical report summarizes methodologies, processes, and the main assumptions of three building energy modeling programs (BEMPs) for HVAC calculations: EnergyPlus, DeST, and DOE-2.1E, and test cases are designed to analyze the calculation process in detail. This will help users to get a better understanding of BEMPs and the research methodology of building simulation. This will also help build a foundation for building energy code development and energy labeling programs.

13

BLACK-BOX MODELLING OF HVAC SYSTEM: IMPROVING THE PERFORMANCES OF NEURAL NETWORKS  

E-Print Network (OSTI)

BLACK-BOX MODELLING OF HVAC SYSTEM: IMPROVING THE PERFORMANCES OF NEURAL NETWORKS Eric FOCK Ile de La Réunion - FRANCE ABSTRACT This paper deals with neural networks modelling of HVAC systems of HVAC system can be modelled using manufacturer design data presented as derived performance maps

Boyer, Edmond

14

Tile of the document: HVAC system component-based modeling and implementation  

E-Print Network (OSTI)

1 Abstract Tile of the document: HVAC system component-based modeling and implementation Karam the foundation for modeling components that are used in HVAC systems (heating, ventilation, and air conditioning such functionalities. #12;2 HVAC system component-based modeling and implementation By Karam H. Rajab Scholarly

Austin, Mark

15

A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2  

E-Print Network (OSTI)

A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2 3 4 Peng Xu, Philip Haves HVAC system (air handling units and air distribution systems). The models are used to predict of automatic documentation methods in the library. INTRODUCTION The increasing complexity of building HVAC

16

Randomized Model Predictive Control for HVAC Systems Alessandra Parisio, Damiano Varagnolo, Daniel Risberg,  

E-Print Network (OSTI)

Randomized Model Predictive Control for HVAC Systems Alessandra Parisio, Damiano Varagnolo, Daniel Conditioning (HVAC) sys- tems play a fundamental role in maintaining acceptable ther- mal comfort and Indoor. A possible solu- tion is to develop effective control strategies for HVAC sys- tems, but this is complicated

Johansson, Karl Henrik

17

Modeling Building Thermal Response to HVAC Virginia Smith, Tamim Sookoor, and Kamin Whitehouse  

E-Print Network (OSTI)

Modeling Building Thermal Response to HVAC Zoning Virginia Smith, Tamim Sookoor, and Kamin,sookoor,whitehouse}@virginia.edu Abstract. HVAC systems account for 38% of building energy usage. Studies have indicated at least 5 HVAC systems to enable room-level zoning where each room is conditioned in- dividually based on its

Whitehouse, Kamin

18

A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS  

E-Print Network (OSTI)

1 A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS T. I describes a control scheme with fault detection capabilities suitable for application to HVAC systems as a reference of correct operation. Faults that occur in the HVAC system under control cause the PI

19

Modeling and optimization of HVAC energy consumption  

Science Journals Connector (OSTI)

A data-driven approach for minimization of the energy to air condition a typical office-type facility is presented. Eight data-mining algorithms are applied to model the nonlinear relationship among energy consumption, control settings (supply air temperature and supply air static pressure), and a set of uncontrollable parameters. The multiple-linear perceptron (MLP) ensemble outperforms other models tested in this research, and therefore it is selected to model a chiller, a pump, a fan, and a reheat device. These four models are integrated into an energy optimization model with two decision variables, the setpoint of the supply air temperature and the static pressure in the air handling unit. The model is solved with a particle swarm optimization algorithm. The optimization results have demonstrated the total energy consumed by the heating, ventilation, and air-conditioning system is reduced by over 7%.

Andrew Kusiak; Mingyang Li; Fan Tang

2010-01-01T23:59:59.000Z

20

Modeling particle deposition on HVAC heat exchangers  

SciTech Connect

Fouling of fin-and-tube heat exchangers by particle deposition leads to diminished effectiveness in supplying ventilation and air conditioning. This paper explores mechanisms that cause particle deposition on heat exchanger surfaces. We present a model that accounts for impaction, diffusion, gravitational settling, and turbulence. Simulation results suggest that some submicron particles deposit in the heat exchanger core, but do not cause significant performance impacts. Particles between 1 and 10 {micro}m deposit with probabilities ranging from 1-20% with fin edge impaction representing the dominant mechanism. Particles larger than 10 {micro}m deposit by impaction on refrigerant tubes, gravitational settling on fin corrugations, and mechanisms associated with turbulent airflow. The model results agree reasonably well with experimental data, but the deposition of larger particles at high velocities is underpredicted. Geometric factors, such as discontinuities in the fins, are hypothesized to be responsible for the discrepancy.

Siegel, J.A.; Nazaroff, W.W.

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

HVAC filter bypass modelling and experimental validation Jeffrey A. Siegel1,*  

E-Print Network (OSTI)

standards that address HVAC filtration efficacy including ASHRAE Standard 52.2 (ASHRAE, 2007) and EN 779HVAC filter bypass modelling and experimental validation Jeffrey A. Siegel1,* , David B. Chojnowski of filter bypass, an ASHRAE Standard 52.2-2007 compliant apparatus was modified to accept filters

Siegel, Jeffrey

22

HVAC Component Data Modeling Using Industry Foundation Classes Vladimir Bazjanac, Lawrence Berkeley National Laboratory, U.S.A.  

E-Print Network (OSTI)

1 HVAC Component Data Modeling Using Industry Foundation Classes Vladimir Bazjanac, Lawrence. This paper describes a number of aspects of a major extension of the HVAC part of the IFC data model. First is the introduction of a more generic approach for handling HVAC components. This includes type information, which

23

HVAC | OpenEI  

Open Energy Info (EERE)

HVAC HVAC Dataset Summary Description The following data-set is for a benchmark residential home for all TMY3 locations across all utilities in the US. The data is indexed by utility service provider which is described by its "unique" EIA ID ( Source National Renewable Energy Laboratory Date Released April 05th, 2012 (2 years ago) Date Updated April 06th, 2012 (2 years ago) Keywords AC apartment CFL coffeemaker Computer cooling cost demand Dishwasher Dryer Furnace gas HVAC Incandescent Laptop load Microwave model NREL Residential television tmy3 URDB Data text/csv icon Residential Cost Data for Common Household Items (csv, 14.5 MiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually Time Period License License Open Data Commons Public Domain Dedication and Licence (PDDL)

24

Comparison of Building Energy Modeling Programs: HVAC Systems  

E-Print Network (OSTI)

or FAU with no control), supply water temperature, pressureunder the same control The supply air temperature and supplyHVAC control strategies of supply air temperature, supply

Zhou, Xin

2014-01-01T23:59:59.000Z

25

Total and Peak Energy Consumption Minimization of Building HVAC Systems Using Model Predictive Control  

E-Print Network (OSTI)

inputs. The idea of modeling building thermal behavior usingThe detail of building thermal modeling is pre- sented in [Modeling and optimal control algorithm design for hvac systems in energy efficient buildings,’’

Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2012-01-01T23:59:59.000Z

26

Minimization of energy consumption in HVAC systems with data-driven models and an interior-point method  

E-Print Network (OSTI)

Minimization of energy consumption in HVAC systems with data-driven models and an interior online 13 June 2014 Keywords: HVAC Interior-point method Internal heat gain Multilayer perceptron-driven approach is applied to minimize energy consumption of a heating, ventilating, and air conditioning (HVAC

Kusiak, Andrew

27

A Qualitive Modeling Approach for Fault Detection and Diagnosis on HVAC Systems  

E-Print Network (OSTI)

This paper describes the basics and first test results of a model based approach using qualitative modeling to perform Fault Detection and Diagnostics (FDD) on HVAC and R systems. A quantized system describing the qualitative behavior of a...

Muller, T.; Rehault, N.; Rist, T.

2013-01-01T23:59:59.000Z

28

Thermal Modeling for a HVAC Controlled Real-life Yong Fu1, Mo Sha1, Chengjie Wu1, Andrew Kutta1, Anna Leavey2, Chenyang Lu1,  

E-Print Network (OSTI)

Thermal Modeling for a HVAC Controlled Real-life Auditorium Yong Fu1, Mo Sha1, Chengjie Wu1, Andrew consumption in build- ings is heating, ventilation, and air conditioning (HVAC). For an HVAC system to provide, especially in large open spaces. To optimize HVAC control, it is important to establish accurate dynamic

Lu, Chenyang

29

A new modelling methodology to control HVAC systems  

Science Journals Connector (OSTI)

Thermal comfort plays an important role in any working environment, but it is a very vague term and it is also very difficult to represent it on modern computers. Its proper definition could be a condition of the mind which expresses satisfaction with the thermal environment and, therefore, it depends on the individual’s physiology and psychology. Several researchers have investigated the relationships between room conditions and thermal comfort. Generally speaking, statistical approaches had been used whereas fuzzy and neural approaches have been recently proposed. In this work it is proposed a new thermal comfort model based on the P.O. Fanger PMV index according to the Institute of the University of Kansas and it has been adapted to a specific indoor ambience with a thermal comfort logger. The results showed that this methodology puts forward an adequate accuracy and suggests temperatures according to the present HVAC standards and those adaptive models show adequate values for thermal neutralities even though they are not suitable for energy saving due to its static value on a daily basis.

José A. Orosa

2011-01-01T23:59:59.000Z

30

Demand Response-Enabled Model Predictive HVAC Load Control in Buildings using Real-Time Electricity Pricing.  

E-Print Network (OSTI)

??A practical cost and energy efficient model predictive control (MPC) strategy is proposed for HVAC load control under dynamic real-time electricity pricing. The MPC strategy… (more)

Avci, Mesut

2013-01-01T23:59:59.000Z

31

A Simple Path Loss Prediction Model for HVAC Systems O. K. Tonguz, D. D. Stancil, A. E. Xhafa, A. G. Cepni, P. V. Nikitin  

E-Print Network (OSTI)

1 A Simple Path Loss Prediction Model for HVAC Systems O. K. Tonguz, D. D. Stancil, A. E. Xhafa, A, and air conditioning (HVAC) cylindrical ducts in 2.4-2.5 GHz frequency band. The model we propose predicts the average power loss between a transmitter-receiver pair in an HVAC duct network. This prediction model

Stancil, Daniel D.

32

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Massieh Najafi1  

E-Print Network (OSTI)

of the building's air conditioning units from reaching occupied spaces, so this unit's energy is simply wastedModeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Massieh Najafi1 , David, Lawrence Berkeley National Laboratory, mdsohn@lbl.gov ABSTRACT Many studies have shown that energy savings

33

IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, VOL. 51, NO. 5, MAY 2003 945 Propagation Model for the HVAC Duct as a  

E-Print Network (OSTI)

for the HVAC Duct as a Communication Channel Pavel V. Nikitin, Member, IEEE, Daniel D. Stancil, Senior Member (HVAC) ducts in buildings are typically hollow metal pipes which can be used as waveguides to carry such a communication system. This paper presents a propagation model for a straight HVAC duct terminated at both ends

Stancil, Daniel D.

34

Energy saving by integrated control of natural ventilation and HVAC systems using model guide for comparison  

Science Journals Connector (OSTI)

Abstract Integrated control by controlling both natural ventilation and HVAC systems based on human thermal comfort requirement can result in significant energy savings. The concept of this paper differs from conventional methods of energy saving in HVAC systems by integrating the control of both these HVAC systems and the available natural ventilation that is based on the temperature difference between the indoor and the outdoor air. This difference affects the rate of change of indoor air enthalpy or indoor air potential energy storage. However, this is not efficient enough as there are other factors affecting the rate of change of indoor air enthalpy that should be considered to achieve maximum energy saving. One way of improvement can be through the use of model guide for comparison (MGFC) that uses physical-empirical hybrid modelling to predict the rate of change of indoor air potential energy storage considering building fabric and its fixture. Three methods (normal, conventional and proposed) are tested on an identical residential building model using predicted mean vote (PMV) sensor as a criterion test for thermal comfort standard. The results indicate that the proposed method achieved significant energy savings compared with the other methods while still achieving thermal comfort.

Raad Z. Homod; Khairul Salleh Mohamed Sahari; Haider A.F. Almurib

2014-01-01T23:59:59.000Z

35

Comparison of Building Energy Modeling Programs: HVAC Systems  

E-Print Network (OSTI)

Comparison of Building Energy Modeling Programs: BuildingComparison of Building Energy Modeling Programs: HVACassumptions of three building energy modeling programs (

Zhou, Xin

2014-01-01T23:59:59.000Z

36

Better Buildings Neighborhood Program Business Models Guide:...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Guide: HVAC Contractor Business Model Better Buildings Neighborhood Program Business Models Guide: HVAC Contractor Business Model HVAC contractor business model...

37

Renovating Residential HVAC Systems HVAC Systems  

E-Print Network (OSTI)

- 1 - LBNL 57406 Renovating Residential HVAC Systems HVAC Systems J.A. McWilliams and I.S. Walker and Air Conditioning), and Stacy Hunt and Ananda Harzell (IBACOS). #12;- 3 - Renovating Residential HVAC Guideline for Residential HVAC Retrofits (http

38

Improving the Efficiency of Light-Duty Vehicle HVAC Systems using...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Light-Duty Vehicle HVAC Systems using Zonal Thermoelectric Devices and Comfort Modeling Improving the Efficiency of Light-Duty Vehicle HVAC Systems using Zonal Thermoelectric...

39

SIMULATION AND EXPERIMENTAL VALIDATION OF AIRBORNE AND STRUCTURE-BORNE NOISE TRANSMISSION IN HVAC PLENUMS.  

E-Print Network (OSTI)

??This research demonstrates the usage of numerical acoustics to model sound and vibrational energy propagation in HVAC ducts and plenums. Noise and vibration in HVAC… (more)

Ramalingam, Srinivasan

2012-01-01T23:59:59.000Z

40

Empirical Methodologies for Improving HVAC Efficiency  

NLE Websites -- All DOE Office Websites (Extended Search)

Empirical Methodologies for Improving HVAC Efficiency Empirical Methodologies for Improving HVAC Efficiency Speaker(s): Anil Aswani Date: September 21, 2012 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Michael Wetter This talk describes the use of empirical methodologies that we have developed for the purpose of improving heating, ventilation, and air-conditioning (HVAC) efficiency through better control algorithms and configuration. We show that semiparametric regression can both identify simplified models of thermal HVAC dynamics while also estimating time-varying heating loads using only real-time temperature measurements from thermostats. These models can be used with our learning-based model predictive control (LBMPC) method in order to improve the energy-efficiency of HVAC. Experiments on testbeds with different types of HVAC show the

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage  

E-Print Network (OSTI)

Optimised Scheduling of a Solar-Assisted HVAC System withA. Mammoli. Modeling of a solar-assisted HVAC system withOPTIMISED SCHEDULING OF A SOLAR-ASSISTED HVAC SYSTEM WITH

Mammoli, Andrea

2014-01-01T23:59:59.000Z

42

HVAC Market Study:  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Market Study: Understanding how energy efficient products get to market Fall 2014 through Winter 2015 Research Manager: Carrie Cobb, clcobb@bpa.gov, 503-230-4985 HVAC systems...

43

Improving the Efficiency of Light-Duty Vehicle HVAC Systems using Zonal Thermoelectric Devices and Comfort Modeling  

Energy.gov (U.S. Department of Energy (DOE))

Summarizes results from a study to identify and demonstrate technical and commercial approaches necessary to accelerate the deployment of zonal TE HVAC systems in light-duty vehicles

44

System dynamics based models for selecting HVAC systems for office buildings: a life cycle assessment from carbon emissions perspective.  

E-Print Network (OSTI)

??This study aims to explore the life cycle environmental impacts of typical heating ventilation and air condition (HVAC) systems including variable air volume (VAV) system,… (more)

Chen, S

2011-01-01T23:59:59.000Z

45

HVAC Maintenance and Technologies  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC - HVAC - Maintenance and Technologies Federal Utility Partnership Working Group Meeting Providence, Rhode Island April 15, 2010 BY Ramin Faramarzi, P.E. Technology Test Centers (TTC) Design and Engineering Services Southern California Edison (SCE) www.sce.com/rttc 2 Outline * Introduction to SCE's TTC * Overview of energy challenges in California (CA) * Role of HVAC in CA's energy and demand equations * Factors affecting HVAC performance * Focus on SCE's research on maintenance faults * Next generation of HVAC equipment * HVAC technologies on SCE's TTC radar * Black boxes - do they all work? 3 SCE's Technology Test Centers * SCE applied research facilities located in Irwindale, CA comprised of 3 test beds: * Refrigeration * HVAC * Lighting * Coming Soon! - A new ZNE lab 4 Refrigeration Testing

46

HVAC Installed Performance  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Installed Performance HVAC Installed Performance ESI, Tim Hanes Context * The building envelope has historically been the focus in residential homes. * The largest consumer of energy in residential homes is typically the HVAC system. * Testing the performance of the HVAC system has not been pursued to its full potential. Technical Approach * Currently very little performance testing is being done to the HVAC system. * The only way to know if a HVAC system is operating correctly is to measure the Btu/h. * This should be done at the equipment and at the the system. Recommended Guidance * Training of HVAC technicians, installers, and salespeople is a must. * If only the technician is trained than implementing the change will not happen. * Public awareness of proper installation and its

47

HVAC Maintenance and Technologies  

Energy.gov (U.S. Department of Energy (DOE))

Presentation covers the HVAC maintenance and technologies, and is given at the Spring 2010 Federal Utility Partnership Working Group (FUPWG) meeting in Providence, Rhode Island.

48

Pedernales Electric Cooperative - HVAC Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pedernales Electric Cooperative - HVAC Rebate Program Pedernales Electric Cooperative - HVAC Rebate Program Pedernales Electric Cooperative - HVAC Rebate Program < Back Eligibility Commercial Residential Commercial Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Program Info State Texas Program Type Utility Rebate Program Utility Rebate Program Rebate Amount Central AC with Gas Furnace: $300 - $400/unit Heat Pump: $400 - $500/unit Dual-Fuel Heat Pump: $400 - $500/unit Geothermal Heat Pump: $1,000/unit Water-Source Heat Pump: $1,000/unit Provider Pedernales Electric Cooperative Pedernales Electric Cooperative offers equipment rebates to members who install energy efficient HVAC equipment. Eligible equipment includes:

49

Ozone removal by HVAC filters  

Science Journals Connector (OSTI)

Residential and commercial HVAC filters that have been loaded with particles during operation in the field can remove ozone from intake or recirculated air. However, knowledge of the relative importance of HVAC filters as a removal mechanism for ozone in residential and commercial buildings is incomplete. We measured the ozone removal efficiencies of clean (unused) fiberglass, clean synthetic filters, and field-loaded residential and commercial filters in a controlled laboratory setting. For most filters, the ozone removal efficiency declined rapidly but converged to a non-zero (steady-state) value. This steady-state ozone removal efficiency varied from 0% to 9% for clean filters. The mean steady-state ozone removal efficiencies for loaded residential and commercial filters were 10% and 41%, respectively. Repeated exposure of filters to ozone following a 24-h period of no exposure led to a regeneration of ozone removal efficiency. Based on a theoretical scaling analysis of mechanisms that are involved in the ozone removal process, we speculate that the steady-state ozone removal efficiency is limited by reactant diffusion out of particles, and that regeneration is due to internal diffusion of reactive species to sites available to ozone for reaction. Finally, by applying our results to a screening model for typical residential and commercial buildings, HVAC filters were estimated to contribute 22% and 95%, respectively, of total ozone removal in HVAC systems.

P. Zhao; J.A. Siegel; R.L. Corsi

2007-01-01T23:59:59.000Z

50

CALIFORNIA ENERGY Large HVAC Building  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Large HVAC Building Survey Information Database of Buildings over 100 Design of Large Commercial HVAC Systems research project, one of six research elements in the Integrated Design of Large Commercial HVAC Systems Integrated Design of Small Commercial HVAC Systems Integrated

51

Model Predictive Control of HVAC Systems: Implementation and Testing at the University of California, Merced  

E-Print Network (OSTI)

13]  Wetter,  M..  2009.   “Modelica?based  Modeling  and 14]  Wetter,  M..  2009.   “Modelica?based  Modeling  and modeling  language  Modelica.   Steady  state  models  of 

Haves, Phillip

2010-01-01T23:59:59.000Z

52

HVAC Installed Performance  

Energy.gov (U.S. Department of Energy (DOE))

This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question HVAC proper installation energy savings: over-promising or under-delivering?"

53

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues  

E-Print Network (OSTI)

challenges of modeling building maintenance issues usinguse, Building simulation, EnergyPlus, Fault modeling, HVACbuildings in various climates, and developing modeling

Wang, Liping

2014-01-01T23:59:59.000Z

54

Improving efficiency of a vehicle HVAC system with comfort modeling, zonal design, and thermoelectric devices  

Energy.gov (U.S. Department of Energy (DOE))

Discusses progress on thermal comfort modeling and detailed design, fabrication, and component/system-level testing of TE architecture

55

2014-12-22 Issuance: Alternative Efficiency Determination Methods, Basic Model Definition, and Compliance for Commercial HVAC, Refrigeration, and Water Heating Equipment; Final Rule  

Energy.gov (U.S. Department of Energy (DOE))

This document is a pre-publication Federal Register final rule regarding alternative efficiency determination methods, basic model definition, and compliance for commercial HVAC, refrigeration, and water heating equipment , as issued by the Deputy Assistant Secretary for Energy Efficiency on December 22, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

56

A Fault Detection and Diagnosis Method for HVAC Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

A Fault Detection and Diagnosis Method for HVAC Systems A Fault Detection and Diagnosis Method for HVAC Systems Speaker(s): Peng Xu Date: December 2, 2002 - 12:00pm Location: Bldg. 90 There is a growing consensus that most buildings do not perform as well as intended and that faults in HVAC systems are widespread in commercial buildings. An automated fault detection and diagnosis tool for HVAC systems is being developed, based on an integrated, life-cycle, approach to commissioning and performance monitoring. The tool uses component-level HVAC equipment models implemented in the SPARK equation-based simulation environment. The models are configured using design information and component manufacturers' data and then fine-tuned to match the actual performance of the equipment by using data measured during functional tests

57

Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues  

E-Print Network (OSTI)

offset Control sensors such as supply air temperature (SAT)a designed supply air temperature to control is 13?C, theSupply air temperature sensor (SAT) offset Impacts Simulated Scenarios Direct modeling, adjust SAT setpoint controls,

Wang, Liping

2014-01-01T23:59:59.000Z

58

Building Energy Software Tools Directory: HVAC 1 Toolkit  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC 1 Toolkit HVAC 1 Toolkit HVAC 1 Toolkit logo. The Toolkit for Primary HVAC System Energy Calculations is a collection of thirty-eight separate subroutines and corresponding documentation that describes algorithms for predicting the performance of HVAC components. The Toolkit documentation includes thorough descriptions of the component models and solution algorithms, detailed information on the structure of the individual FORTRAN 77 routines, as well as illustrative examples of system simulations with the Toolkit routines. The Toolkit serves two purposes: modules for large-scale simulation and stand-alone component performance prediction. The Toolkit components can also be used to calculate the energy performance of a component with a dedicated driver program to provide the necessary information flow to the Toolkit routines.

59

Definition: HVAC | Open Energy Information  

Open Energy Info (EERE)

HVAC HVAC Jump to: navigation, search Dictionary.png HVAC An abbreviation for the heating, ventilation, and air-conditioning system; the system or systems that condition air in a building.[1] View on Wikipedia Wikipedia Definition HVAC is the technology of indoor and vehicular environmental comfort. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. Refrigeration is sometimes added to the field's abbreviation as HVAC&R or HVACR, or ventilating is dropped as in HACR (such as the designation of HACR-rated circuit breakers). HVAC is important in the design of medium to large industrial and office buildings such as skyscrapers and in marine environments such as aquariums, where safe and

60

Chaplygin electron gas model  

E-Print Network (OSTI)

We provide a new electromagnetic mass model admitting Chaplygin gas equation of state. We investigate three specializations, the first characterized by a vanishing effective pressure, the second provided with a constant effective density and the third is described by a constant effective pressure. For these specializations two particular cases are discussed. In addition, for specialization I, case I we found isotropic coordinate as well as Kretschmann scalar, and for specialization III, case II two special scenarios have been studied.

I. Radinschi; F. Rahaman; M. Kalam; K. Chakraborty

2008-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

The Impact of Uncertain Physical Parameters on HVAC Demand Response  

SciTech Connect

HVAC units are currently one of the major resources providing demand response (DR) in residential buildings. Models of HVAC with DR function can improve understanding of its impact on power system operations and facilitate the deployment of DR technologies. This paper investigates the importance of various physical parameters and their distributions to the HVAC response to DR signals, which is a key step to the construction of HVAC models for a population of units with insufficient data. These parameters include the size of floors, insulation efficiency, the amount of solid mass in the house, and efficiency of the HVAC units. These parameters are usually assumed to follow Gaussian or Uniform distributions. We study the effect of uncertainty in the chosen parameter distributions on the aggregate HVAC response to DR signals, during transient phase and in steady state. We use a quasi-Monte Carlo sampling method with linear regression and Prony analysis to evaluate sensitivity of DR output to the uncertainty in the distribution parameters. The significance ranking on the uncertainty sources is given for future guidance in the modeling of HVAC demand response.

Sun, Yannan; Elizondo, Marcelo A.; Lu, Shuai; Fuller, Jason C.

2014-03-01T23:59:59.000Z

62

CALIFORNIA ENERGY Large HVAC Energy Impact Report  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Large HVAC Energy Impact Report Statewide Energy Impact Report are part of the Integrated Design of Large Commercial HVAC Systems research project. The reports: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

63

A Quasi-Dynamic HVAC and Building Simulation Methodology  

E-Print Network (OSTI)

This thesis introduces a quasi-dynamic building simulation methodology which complements existing building simulators by allowing transient models of HVAC (heating, ventilating and air-conditioning) systems to be created in an analogous way...

Davis, Clinton Paul

2012-07-16T23:59:59.000Z

64

Gas Kick Mechanistic Model  

E-Print Network (OSTI)

Gas kicks occur during drilling when the formation pressure is greater than the wellbore pressure causing influx of gas into the wellbore. Uncontrolled gas kicks could result in blowout of the rig causing major financial loss and possible injury...

Zubairy, Raheel

2014-04-18T23:59:59.000Z

65

Advanced HVAC Systems | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

HVAC Systems Advanced HVAC Systems Lead Performer: Oak Ridge National Laboratory - Oak Ridge, TN Partners: -- Indian Institute of Technology Bombay - Maharashtra, India -- Malviya...

66

Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting with EPRI-REEPS 2.1  

E-Print Network (OSTI)

LBL-34045 UC-1600 Residential HVAC Data, Assumptions and Methodology for End-Use Forecasting-uses include Heating, Ventilation and Air Conditioning (HVAC). Our analysis uses the modeling framework provided by the HVAC module in the Residential End-Use Energy Planning System (REEPS), which was developed

67

HVAC: Maintaining HVAC equipment with air intake filters  

Science Journals Connector (OSTI)

Airborne debris, such as domestic waste, leaves, pollen, insects and even plastic carrier bags is the leading cause of fouling and clogging of cooling towers, heat exchangers, air cooled chillers and other HVAC systems. Richard Betts, managing director of UK-based RAB Specialist Engineers, provides Filtration+Separation with some practical advice on how to maintain HVAC equipment.

Richard Betts

2013-01-01T23:59:59.000Z

68

REDESIGN OF HVAC SYSTEM TO IMPROVE ENERGY EFFICIENCY OF EDUCATIONAL BUILDING.  

E-Print Network (OSTI)

??An energy modeling software was used to analyze the current building configuration and simulations were performed in an attempt to redesign the current HVAC system… (more)

Hagene, Brian Matthew

2012-01-01T23:59:59.000Z

69

HVAC Improvements for Existing Houses  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Improvements for Existing Houses HVAC Improvements for Existing Houses Speaker(s): Chryséis Bovagnet Date: September 5, 2002 - 12:00pm Location: Bldg. 90 Many older houses in the US are either not well designed from a thermal point of view or have HVAC (Heating Ventilation and Air Conditioning) systems in need of repairs or improvements. The building envelopes tend to have poor insulation and lots of leakage, and the HVAC systems are inefficient. The cooling/heating equipment is often located outside of the conditioned space (e.g. in attics or crawlspaces) with ducts that leak and have poor insulation, which cause energy loss and bad occupant comfort on peak days or in extreme climates. We developed a series of retrofits that will allow us to reduce the energy consumption of residential HVAC

70

HVAC's Variable Refrigerant Flow (VRF) Technology  

E-Print Network (OSTI)

1 Comfort by Design Steve Jones Commercial Sales Manager for Mitsubishi Southwest Business Unit HVAC?s Variable Refrigerant Flow (VRF) Technology HVAC Industry Overview HVAC Market Dollar Volume $18 Billion Source:;NABH Research....2M Systems Ductless is a small percent of the U.S. HVAC market but current building and energy usage trends indicate a large growth opportunity Determining the Proper Application Worldwide Usage-Opportunity Window Unitary Chillers...

Jones, S.

2012-01-01T23:59:59.000Z

71

Strategy Guideline: HVAC Equipment Sizing  

SciTech Connect

The heating, ventilation, and air conditioning (HVAC) system is arguably the most complex system installed in a house and is a substantial component of the total house energy use. A right-sized HVAC system will provide the desired occupant comfort and will run efficiently. This Strategy Guideline discusses the information needed to initially select the equipment for a properly designed HVAC system. Right-sizing of an HVAC system involves the selection of equipment and the design of the air distribution system to meet the accurate predicted heating and cooling loads of the house. Right-sizing the HVAC system begins with an accurate understanding of the heating and cooling loads on a space; however, a full HVAC design involves more than just the load estimate calculation - the load calculation is the first step of the iterative HVAC design procedure. This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

Burdick, A.

2012-02-01T23:59:59.000Z

72

HVAC efficiency: Can filter selection reduce HVAC energy costs?  

Science Journals Connector (OSTI)

In a society becoming more aware of the effects of energy consumption, Zoe Grainge takes a look at whether filter efficiency can go some way to ease the energy burden of HVAC systems.

Zoe Grainge

2007-01-01T23:59:59.000Z

73

Holographic Chaplygin gas model  

E-Print Network (OSTI)

In this paper we consider a correspondence between the holographic dark energy density and Chaplygin gas energy density in FRW universe. Then we reconstruct the potential and the dynamics of the scalar field which describe the Chaplygin cosmology.

M R Setare

2007-04-27T23:59:59.000Z

74

Energy-Efficient Building HVAC Control Using Hybrid System LBMPC  

E-Print Network (OSTI)

Improving the energy-efficiency of heating, ventilation, and air-conditioning (HVAC) systems has the potential to realize large economic and societal benefits. This paper concerns the system identification of a hybrid system model of a building-wide HVAC system and its subsequent control using a hybrid system formulation of learning-based model predictive control (LBMPC). Here, the learning refers to model updates to the hybrid system model that incorporate the heating effects due to occupancy, solar effects, outside air temperature (OAT), and equipment, in addition to integrator dynamics inherently present in low-level control. Though we make significant modeling simplifications, our corresponding controller that uses this model is able to experimentally achieve a large reduction in energy usage without any degradations in occupant comfort. It is in this way that we justify the modeling simplifications that we have made. We conclude by presenting results from experiments on our building HVAC testbed, which s...

Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

2012-01-01T23:59:59.000Z

75

Bianchi Models with Chaplygin Gas  

E-Print Network (OSTI)

Einstein Gravitational Field Equations (EFE) of Chaplygin gas dominated Bianchi-type models are obtained by using metric approximation. The solutions of equations for a special case, namely Bianchi I model which is a generalization of isotropic Friedmann-Robertson-Walker (FRW) cosmology, are obtained. The early and late behaviours of some kinematic parameters in model are presented in graphically.

Gülçin; Uluyazi; Özgür Sevinc

2012-09-13T23:59:59.000Z

76

SIMULATION OF RESIDENTIAL HVAC SYSTEM PERFORMANCE  

E-Print Network (OSTI)

1 LBNL-47622 SIMULATION OF RESIDENTIAL HVAC SYSTEM PERFORMANCE Walker, I., Siegel, J ..................................................... 9 #12;3 ABSTRACT In many parts of North America residential HVAC systems are installed outside of the simulations is that they are dynamic - which accounts for cyclic losses from the HVAC system and the effect

77

Energirigtige pumpekoblinger i HVAC-systemer  

E-Print Network (OSTI)

Energirigtige pumpekoblinger i HVAC-systemer PSO 2003 - FORSKNING & UDVIKLING I EFFEKTIV energieffektive HVAC-aggregater #12;InformationomProjektnr.:335-021 PROCESSEN: Projektet er gennemført af en reguleringsprincipper, mens Exhausto har leveret HVAC-aggregat og knowhow inden for klimasystemer. Grundfos

78

PROJECT REPORT HVAC EQUIPMENT DEMOGRAPHICS AND CAPACITY  

E-Print Network (OSTI)

PROJECT REPORT HVAC EQUIPMENT DEMOGRAPHICS AND CAPACITY ANALYSIS TOOLS APPLICABLE TO MULTI Commercial HVAC Design Process 12 5.0 Conclusion 18 6.0 References 19 TABLE OF CONTENTS SECTIONS #12;MULTI performance by collectively improving the enve- lope, lighting and HVAC systems. The primary goals of the UC

California at Davis, University of

79

CALIFORNIA ENERGY Small HVAC Database Of Monitored  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Small HVAC Database Of Monitored Information Database of Compiled of the Integrated Design of Small Commercial HVAC Systems research project. The reports are a result of funding: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

80

CALIFORNIA ENERGY Small HVAC Problems and Potential  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Small HVAC Problems and Potential Savings Reports Summary of Problems of the Integrated Design of Small Commercial HVAC Systems research project. The reports are a result of funding: Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

CALIFORNIA ENERGY Small HVAC System Design Guide  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Small HVAC System Design Guide DESIGNGUIDELINES October 2003 500;#12;Small HVAC System Design Guide Acknowledgements i Acknowledgements The products and outcomes presented; Darren Goody, PECI, Design Guide review. #12;Small HVAC System Design Guide Preface ii Preface The Small

82

Development Practice in HVAC Controls  

NLE Websites -- All DOE Office Websites (Extended Search)

Development Practice in HVAC Controls Development Practice in HVAC Controls Speaker(s): John Zhou Date: April 11, 2011 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Philip Haves The presentation will introduce development tools and design considerations used in HVAC controls development. Controls development use simulation, lab testing and field trial at different phases of the project cycle to improve control performance and to achieve rapid development. Development starts with simulation to originate and define algorithm concept. The concept is then implemented in a prototype controller, and tested in lab environment. The concept is refined and verified by analyzing lab results. In the final phase of development, controllers with refined and verified algorithms are installed in field trial sites to ensure system integration and to confirm

83

Influence Of Three Dynamic Predictive Clothing Insulation Models On Building Energy Use, HVAC Sizing And Thermal Comfort  

E-Print Network (OSTI)

Predictive Clothing Insulation Models based on Outdoor AirPREDICTIVE CLOTHING INSULATION MODELS ON BUILDING ENERGYthat the clothing insulation is equal to a constant value of

Schiavon, Stefano; Lee, Kwang Ho

2013-01-01T23:59:59.000Z

84

An experimental system for advanced heating, ventilating and air conditioning (HVAC) control  

Science Journals Connector (OSTI)

While having the potential to significantly improve heating, ventilating and air conditioning (HVAC) system performance, advanced (e.g., optimal, robust and various forms of adaptive) controllers have yet to be incorporated into commercial systems. Controllers consisting of distributed proportional-integral (PI) control loops continue to dominate commercial HVAC systems. Investigation into advanced HVAC controllers has largely been limited to proposals and simulations, with few controllers being tested on physical systems. While simulation can be insightful, the only true means for verifying the performance provided by HVAC controllers is by actually using them to control an HVAC system. The construction and modeling of an experimental system for testing advanced HVAC controllers, is the focus of this article. A simple HVAC system, intended for controlling the temperature and flow rate of the discharge air, was built using standard components. While only a portion of an overall HVAC system, it is representative of a typical hot water to air heating system. In this article, a single integrated environment is created that is used for data acquisition, controller design, simulation, and closed loop controller implementation and testing. This environment provides the power and flexibility needed for rapid prototyping of various controllers and control design methodologies.

Michael Anderson; Michael Buehner; Peter Young; Douglas Hittle; Charles Anderson; Jilin Tu; David Hodgson

2007-01-01T23:59:59.000Z

85

NREL: Transportation Research - Data, Models, and Tools  

NLE Websites -- All DOE Office Websites (Extended Search)

fuel providers, and other transportation decision-makers reduce petroleum use. CoolSim HVAC Model Heating, ventilating, and air conditioning (HVAC) model that solves energy,...

86

Software tools for HVAC research  

Science Journals Connector (OSTI)

Energy saving methods can be employed to reduce energy consumption in buildings, or improve indoor thermal conditions. An example of those methods is the use of permeable coverings, but there are other important parameters like thermal inertia. To understand ... Keywords: Building, Computer, Design, Energy saving, HVAC, Software tools

José A. Orosa; Armando C. Oliveira

2011-10-01T23:59:59.000Z

87

2014-09-18 Issuance: Energy Conservation Standard for Alternative Efficiency Determination Methods, Basic Model Definition, and Compliance for Commercial HVAC, Refrigeration, and Water Heating Equipment; Supplemental Notice of Proposed Rulemaking  

Energy.gov (U.S. Department of Energy (DOE))

This document is a pre-publication Federal Register supplemental notice of proposed rulemaking regarding energy conservation standards for alternative efficiency determination methods, basic model definition, and compliance for commercial HVAC, Refrigeration, and Water Heating Equipment, as issued by the Deputy Assistant Secretary for Energy Efficiency on September 18, 2014. Though it is not intended or expected, should any discrepancy occur between the document posted here and the document published in the Federal Register, the Federal Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document.

88

STATE OF CALIFORNIA CERTIFICATE OF COMPLIANCE, PRESCRIPTIVE HVAC ALTERATIONS  

E-Print Network (OSTI)

STATE OF CALIFORNIA CERTIFICATE OF COMPLIANCE, PRESCRIPTIVE HVAC ALTERATIONS CEC-MECH-1C-ALT-HVAC (Revised 07/10) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE MECH-1C-ALT-HVAC Prescriptive HVAC Steps" column below. Note: After installation of HVAC units and/or ducts, the Installation

89

Modeling of Solar-Powered Single-Effect Absorption Cooling System and Supermarket Refrigeration/HVAC System.  

E-Print Network (OSTI)

??This thesis consists of two different research problems. In the first one, the aim is to model and simulate a solar-powered, single-effect, absorption refrigeration system… (more)

Bahman, Ammar

2011-01-01T23:59:59.000Z

90

Modeling of Solar-Powered Single-Effect Absorption Cooling System and Supermarket Refrigeration/HVAC System.  

E-Print Network (OSTI)

?? This thesis consists of two different research problems. In the first one, the aim is to model and simulate a solar-powered, single-effect, absorption refrigeration… (more)

Bahman, Ammar Mohammad Khalil

2011-01-01T23:59:59.000Z

91

HVAC system optimization with CO2 concentration control using genetic algorithms  

Science Journals Connector (OSTI)

This study describes the use of genetic algorithms (GAs) for operating standard HVAC systems (HVAC—heating, ventilation and air conditioning) in order to optimize performance, primarily with regard to power saving. Genetic algorithms were introduced as an instrument for solving optimization problems. Analytic optimization procedures are widely used in other fields of engineering, but they are difficult to operate within HVAC systems, because the range of the research is usually too broad, the problems are not linear but rather discontinuous, and they mostly have complex limitations. This is why for this type of system genetic algorithms are used, since they have the qualities of robustness and efficiency that are crucial for finding the optimal solution. A simulation is conducted in order to demonstrate how much power can be saved by using the suggested method of CO2 concentration control in a standard HVAC system. In addition to Matlab Simulink, the suggested method is verified with Energy software.

Velimir Congradac; Filip Kulic

2009-01-01T23:59:59.000Z

92

HVAC Technician | Princeton Plasma Physics Lab  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Technician HVAC Technician Department: Facilities Supervisor(s): Tom Ward Staff: L&S 07 Requisition Number: 1300884 Under the supervision of the General Lead Technician and Lead HVAC Technician, the incumbent will be responsible for the installation, preventative maintenance, troubleshooting and repair of various HVAC and refrigeration equipment; local HVAC control systems and ancillary support equipment; and will work with other groups within the Division and throughout the Laboratory to ensure long-term, safe and efficient operation of HVAC and refrigeration systems. All tasks must be completed in a timely, cost efficient manner, support on-going sustainability initiatives and energy efficiency programs at the Laboratory. The incumbent is expected to utilize thorough theoretical knowledge and techniques to accomplish

93

HVAC Commissioning - A Status Report in Taiwan  

E-Print Network (OSTI)

HVAC HVAC CommisioningCommisioning ?? A Status Report in TaiwanA Status Report in Taiwan Dr. K.H. YangDr. K.H. Yang Fellow ASHRAEFellow ASHRAEProfessor, National Sun Professor, National Sun Yat... ,decided to conduct an overall renovation program for the HVAC systems of existing governmental buildings where it is mandatory to adapt BEMS and conducting system commissioning .?This program not only constructs an important step in responding...

Yang, K. H.

2006-01-01T23:59:59.000Z

94

Mathematical models of natural gas consumption  

E-Print Network (OSTI)

Mathematical models of natural gas consumption Kristian Sabo, Rudolf Scitovski, Ivan of natural gas consumption Kristian Sabo, Rudolf Scitovski, Ivan Vazler , Marijana Zeki-Susac ksabo of natural gas consumption hourly fore- cast on the basis of hourly movement of temperature and natural gas

Scitovski, Rudolf

95

Measuring Advances in HVAC Distribution System Design  

E-Print Network (OSTI)

Advances in HV AC Distribution System Design Ellen FranconiAdvances in HVAC Distribution System Design Ellen Franconisavings result from distribution system design improvements,

Franconi, E.

2011-01-01T23:59:59.000Z

96

HVAC, Water Heating, and Appliances | Department of Energy  

Energy Savers (EERE)

HVAC, Water Heating, and Appliances HVAC, Water Heating, and Appliances How a Small Business is Transforming the Cold Climate Heating Market How a Small Business is Transforming...

97

Energy Department Releases Roadmaps on HVAC Technologies, Water...  

Energy Savers (EERE)

Energy Department Releases Roadmaps on HVAC Technologies, Water Heating, Appliances, and Low-GWP Refrigerants Energy Department Releases Roadmaps on HVAC Technologies, Water...

98

NETL Sorbents Licensed to Help Lower Power Draw of HVAC  

NLE Websites -- All DOE Office Websites (Extended Search)

the energy efficiency of commercial HVAC (heating, ventilation, and air conditioning) systems. HVAC is one of the largest draws of electric power in the United States. In many...

99

DOE Convening Report on Certification of Commercial HVAC and...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Convening Report on Certification of Commercial HVAC and CRE Products DOE Convening Report on Certification of Commercial HVAC and CRE Products This document is the convening...

100

Project examples Install new HVAC, electrical, fire protection,  

E-Print Network (OSTI)

Project examples Install new HVAC, electrical, fire protection, and plumbing systems in Mechanical. · Totransformthisspaceandincreaseaccessibility, anelevatorisrequired.Currently,Blakelydoesnot haveone. Replace HVAC and electrical system

Blanchette, Robert A.

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Solid State Vehicular Generators and HVAC Development | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Solid State Vehicular Generators and HVAC Development Solid State Vehicular Generators and HVAC Development 2009 DOE Hydrogen Program and Vehicle Technologies Program Annual Merit...

102

Chapter 5: Lighting, HVAC, and Plumbing | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5: Lighting, HVAC, and Plumbing Chapter 5: Lighting, HVAC, and Plumbing Chapter 5 of the LANL Sustainable Design Guide with guidelines for developing sustainable, healthy,...

103

System-Level Monitoring and Diagnosis of Building HVAC System.  

E-Print Network (OSTI)

??Heating, ventilation, and air conditioning (HVAC) is an indoor environmental technology that is extensively instrumented for large-scale buildings. Among all subsystems of buildings, the HVAC… (more)

Wu, Siyu

2013-01-01T23:59:59.000Z

104

Integration of HVAC System Design with Simplified Duct Distribution...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Integration of HVAC System Design with Simplified Duct Distribution - Building America Top Innovation Integration of HVAC System Design with Simplified Duct Distribution - Building...

105

Utveckling av provmetodik för HVAC på lastbil; Development of test methodology for climatic testing of truck HVAC on trucks.  

E-Print Network (OSTI)

?? I detta examensarbetet undersöks hur provningen av HVAC på lastbilar skall utföras i klimatvindtunneln CD7 som Scania färdigställer till år 2013. HVAC omfattar kupéuppvärmning,… (more)

Jonsson, Björn-Emil

2011-01-01T23:59:59.000Z

106

Optimization Control Strategies for HVAC Terminal Boxes  

E-Print Network (OSTI)

The HVAC terminal boxes are one of the major building HVAC components. They directly impact the building room comfort conditions and the energy costs. How to operate the box in a highly energy efficient way and maintain the room comfort level...

Zhu, Y.; Batten, T.; Noboa, H.; Claridge, D. E.; Turner, W. D.; Liu, M.; Zhou, J.; Cameron, C.; Keeble, D.; Hirchak, R.

2000-01-01T23:59:59.000Z

107

Ventilation, temperature, and HVAC characteristics in small and medium  

NLE Websites -- All DOE Office Websites (Extended Search)

Ventilation, temperature, and HVAC characteristics in small and medium Ventilation, temperature, and HVAC characteristics in small and medium commercial buildings in California Title Ventilation, temperature, and HVAC characteristics in small and medium commercial buildings in California Publication Type Journal Article Refereed Designation Refereed Year of Publication 2012 Authors Bennett, Deborah H., William J. Fisk, Michael G. Apte, X. Wu, Amber L. Trout, David Faulkner, and Douglas P. Sullivan Journal Indoor Air Volume 22 Issue 4 Pagination 309-20 Abstract This field study of 37 small and medium commercial buildings throughout California obtained information on ventilation rate, temperature, and heating, ventilating, and air-conditioning (HVAC) system characteristics. The study included seven retail establishments; five restaurants; eight offices; two each of gas stations, hair salons, healthcare facilities, grocery stores, dental offices, and fitness centers; and five other buildings. Fourteen (38%) of the buildings either could not or did not provide outdoor air through the HVAC system. The air exchange rate averaged 1.6 (s.d. = 1.7) exchanges per hour and was similar between buildings with and without outdoor air supplied through the HVAC system, indicating that some buildings have significant leakage or ventilation through open windows and doors. Not all buildings had sufficient air exchange to meet ASHRAE 62.1 Standards, including buildings used for fitness centers, hair salons, offices, and retail establishments. The majority of the time, buildings were within the ASHRAE temperature comfort range. Offices were frequently overcooled in the summer. All of the buildings had filters, but over half the buildings had a filter with a minimum efficiency reporting value rating of 4 or lower, which are not very effective for removing fine particles. PRACTICAL IMPLICATIONS: Most U.S. commercial buildings (96%) are small- to medium-sized, using nearly 18% of the country's energy, and sheltering a large population daily. Little is known about the ventilation systems in these buildings. This study found a wide variety of ventilation conditions, with many buildings failing to meet relevant ventilation standards. Regulators may want to consider implementing more complete building inspections at commissioning and point of sale.

108

Commercial Building HVAC: How it Affects People  

NLE Websites -- All DOE Office Websites (Extended Search)

Commercial Building HVAC: How it Affects People Commercial Building HVAC: How it Affects People Speaker(s): William Fisk Date: November 13, 2000 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: David Faulkner Commercial building heating, ventilating, and air conditioning (HVAC) systems are designed primarily to maintain a reasonable level of thermal comfort while limiting first costs and energy consumption. However, research conducted predominately within the last decade suggests that commercial building HVAC significantly influences human outcomes other than thermal comfort, including the health, satisfaction, and work performance of the building's occupants. This presentation will review the relationships of these outcomes with HVAC system type, filtration system efficiency, indoor air temperature, and outside air ventilation rate.

109

2013 Energy Code Changes That Effect the HVAC  

E-Print Network (OSTI)

2013 Energy Code Changes That Effect the HVAC Industry Tav Commins Mechanical Engineer California Energy Commission #12;HVAC Mandatory Measures For All Newly Installed Residential HVAC Systems (New Watt Draw at .58 W/CFM, or (return duct and filter sizing) MERV 6 Filter #12;Residential HVAC Measures

California at Davis, University of

110

CALIFORNIA ENERGY Large HVAC Field and Baseline Data  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION Large HVAC Field and Baseline Data Field Data Collection: Site Survey of the Integrated Design of Large Commercial HVAC Systems research project. The reports are a result of funding Design of Large Commercial HVAC Systems Integrated Design of Small Commercial HVAC Systems Integrated

111

Cooling and Dehumidification HVAC Technology for 1990s  

E-Print Network (OSTI)

Desiccant Cooling and Dehumidification HVAC Technology for 1990s HVAC: Heating, Ventilation Research Trusts SERI #12;Challenges Facing HVAC Industry in 1990's * Reduction of CFCs * Indoor air quality to solve the problems of the HVAC industry faced in1990's for space conditioning. SERI #12;l- = m mN a- mg

Oak Ridge National Laboratory

112

Residential HVAC Indoor Air Quality(ASHRAE 62.2)  

E-Print Network (OSTI)

Residential HVAC && Indoor Air Quality(ASHRAE 62.2) Tav Commins #12;Contact Information · Energy construction, Additions /Alterations · Nonresidential and Residential #12;Residential HVAC && Indoor Air Quality(ASHRAE 62.2) ·HVAC EfficiencyHVAC Efficiency ·Quality Installation (HERS Measures) S li b HERS R t

113

Gas Distribution Modeling using Sparse Gaussian Process Mixture Models  

E-Print Network (OSTI)

Gas Distribution Modeling using Sparse Gaussian Process Mixture Models Cyrill Stachniss1 Christian-- In this paper, we consider the problem of learning a two dimensional spatial model of a gas distribution with a mobile robot. Building maps that can be used to accurately predict the gas concentration at query

Stachniss, Cyrill

114

Salsbury and Diamond: Automated Testing of HVAC Systems for Commissioning -1 -Automated Testing of HVAC Systems for Commissioning  

E-Print Network (OSTI)

and Diamond: Automated Testing of HVAC Systems for Commissioning - 1 - Automated Testing of HVAC Systems This paper describes an approach to the automation of the commissioning of HVAC systems. The approach of many HVAC systems is limited more by poor installation, commissioning, and maintenance than by poor

115

Investigation of IAQ-Relevant Surface Chemistry and Emissions on HVAC Filter Materials  

E-Print Network (OSTI)

VOCs emitted by reactions of HVAC filters with ozone usingand Emissions on HVAC Filter Materials Hugo Destaillats andChemistry and Emissions on HVAC Filter Materials Authors:

Destaillats, Hugo

2010-01-01T23:59:59.000Z

116

Bus HVAC energy consumption test method based on HVAC unit behavior  

Science Journals Connector (OSTI)

This paper presents a test method for determination of energy consumption of bus HVAC unit. The energy consumption corresponds to a bus engine fuel consumption increase during the HVAC unit operation period. The HVAC unit energy consumption is determined from the unit input power, which is measured under several levels of bus engine speeds and at different levels of testing heat load in the laboratory environment. Since the bus engine fuel consumption is incrementally induced by powering an HVAC unit, the results are subsequently recalculated to the unit fuel consumption under the defined road cycles in terms of standardized diesel engine. The method is likewise applicable either for classic or electric HVAC units with a main consumer (compressor or high voltage alternator) mechanically driven directly from the bus engine and also for electric HVAC units supplied from an alternative electric energy source in case of hybrid or fully electric buses.

M. Hegar; M. Kolda; M. Kopecka; V. Rajtmajer; A. Ryska

2013-01-01T23:59:59.000Z

117

Gas Model of Gravitons with Light Speed  

E-Print Network (OSTI)

We first review some aspects of gravitational wave and the thermodynamic expression of Einstein field equations, these achieved conclusions allow people to think of Einstein's gravitational wave as a kind of sound wave in ordinary gas which propagates as an adiabatic compression wave. In the following, using the properties of photon gas in "white wall box", we find an analogous relationship between ordinary gas and photon gas through sound velocity formula. At last, by taking the ordinary gas as an intermediary, we find that gravitational wave is analogous to photon gas, or equally, gravitons are analogous to photons although they are different in some ways such as spins and coupling strengths, and these different properties don't affect their propagation speeds. Utilizing this analogous relationship, we achieve the gas model of gravitons and this model naturally gives out the light speed of gravitons

Ming Chen; Yong-Chang Huang

2014-06-17T23:59:59.000Z

118

Agegraphic Chaplygin gas model of dark energy  

E-Print Network (OSTI)

We establish a connection between the agegraphic models of dark energy and Chaplygin gas energy density in non-flat universe. We reconstruct the potential of the agegraphic scalar field as well as the dynamics of the scalar field according to the evolution of the agegraphic dark energy. We also extend our study to the interacting agegraphic generalized Chaplygin gas dark energy model.

Ahmad Sheykhi

2010-02-07T23:59:59.000Z

119

Utveckling av provmetodik för HVAC på lastbil; Development of test methodology for truck HVAC.  

E-Print Network (OSTI)

?? The issue about how Scania shall perform HVAC tests in the climatic wind tunnel CD7, which Scania is about to complete by year 2013,… (more)

Tedenäs, Jimmy

2011-01-01T23:59:59.000Z

120

Free-cooling: A total HVAC design concept  

SciTech Connect

This paper discusses a total ''free cooling'' HVAC design concept in which mechanical refrigeration is practically obviated via the refined application of existing technological strategies and a new diffuser terminal. The principles being applied are as follows; Thermal Swing: This is the active contribution of programmed heat storage to overall HVAC system performance. Reverse Diffuser: This is a new air terminal design that facilitates manifesting the thermal storage gains. Developing the thermal storage equation system into a generalized simulation model, optimizing the thermal storage and operating strategies with a computer program and developing related algorithms are subsequently illustrated. Luminair Aspiration: This feature provides for exhausting all luminair heat totally out of the building envelope, via an exhaust duct system and insulated boots. Two/Three-Stage Evaporative Cooling: This concept comprises a system of air conditioning that entails a combination of closed and open loop evaporative cooling with standby refrigeration only.

Janeke, C.E.

1982-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Quantitative Methods for Comparing Different HVAC Control Schemes  

E-Print Network (OSTI)

Experimentally comparing the energy usage and comfort characteristics of different controllers in heating, ventilation, and air-conditioning (HVAC) systems is difficult because variations in weather and occupancy conditions preclude the possibility of establishing equivalent experimental conditions across the order of hours, days, and weeks. This paper is concerned with defining quantitative metrics of energy usage and occupant comfort, which can be computed and compared in a rigorous manner that is capable of determining whether differences between controllers are statistically significant in the presence of such environmental fluctuations. Experimental case studies are presented that compare two alternative controllers (a schedule controller and a hybrid system learning-based model predictive controller) to the default controller in a building-wide HVAC system. Lastly, we discuss how our proposed methodology may also be able to quantify the efficiency of other building automation systems.

Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

2012-01-01T23:59:59.000Z

122

Plutonium Finishing Plant (PFP) HVAC System Component Index  

SciTech Connect

This document lists safety class (SC) and safety significant (SS) components for the Heating Ventilation Air Conditioning (HVAC) and specifies the critical characteristics for Commercial Grade Items (CGI), as required by HNF-PRO-268 and HNF-PRO-18 19. These are the minimum specifications that the equipment must meet in order to properly perform its safety function. There may be several manufacturers or models that meet the critical characteristics for any one item. The Plutonium Finishing Plant (PFP) HVAC System includes sub-systems 25A through 25K. Specific system boundaries and justifications are contained in HNF-SD-CP-SDD-005, ''Definition and Means of Maintaining the Ventilation System Confinement Portion of the PFP Safety Envelope.'' The procurement requirements associated with the system necessitates procurement of some system equipment as Commercial Grade Items in accordance with HNF-PRO-268, ''Control of Purchased Items and Services.''

DIAZ, E.N.

2000-03-30T23:59:59.000Z

123

HVAC Equipment Rebate Program | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Equipment Rebate Program HVAC Equipment Rebate Program HVAC Equipment Rebate Program < Back Eligibility Agricultural Commercial Industrial Installer/Contractor Institutional Multi-Family Residential Nonprofit Schools Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Heat Pumps Maximum Rebate Rebates of greater than $5,000 require pre-approval Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Varies depending on technology and efficiency Provider Efficiency Vermont NOTE: Rebate reservations are required for all boiler and furnace projects. Efficiency Vermont offers rebates for commercial installations of high-efficiency HVAC equipment and controls. For businesses and purchases

124

Recovery Act-Funded HVAC projects  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy was allocated funding from the American Recovery and Reinvestment Act to conduct research into heating, ventilation, and air conditioning (HVAC) technologies and...

125

Interdisciplinary Innovation and Vision in the HVAC  

E-Print Network (OSTI)

potentials for optimizing costs can be found in the HVAC systems when calculated over the total Life-Cycle-Cost (LCC) of a building incorporating planning through to facility management. This requires an accurate plan specifying an efficient technical...

Hecker, T.

2008-01-01T23:59:59.000Z

126

HVAC Energy Recovery Design and Economic Evaluation  

E-Print Network (OSTI)

ENRECO has prepared this paper on HVAC energy recovery to provide the engineer with an overview of the design engineering as well as the economic analysis considerations necessary to evaluate the potential benefits of energy recovery....

Kinnier, R. J.

1979-01-01T23:59:59.000Z

127

A PDI for your HVAC System  

Energy.gov (U.S. Department of Energy (DOE))

This presentation was given at the Summer 2012 DOE Building America meeting on July 25, 2012, and addressed the question "HVAC proper installation energy savings: over-promising or under-deliverying?"

128

Non-Vapor Compression HVAC Technologies Report  

Energy.gov (U.S. Department of Energy (DOE))

While vapor-compression technologies have served heating, ventilation, and air-conditioning (HVAC) needs very effectively, and have been the dominant HVAC technology for close to 100 years, the conventional refrigerants used in vapor-compression equipment contribute to global climate change when released to the atmosphere. The Building Technologies Office is evaluating low-global warming potential (GWP) alternatives to vapor-compression technologies.

129

Simple Cosmological Model with Relativistic Gas  

E-Print Network (OSTI)

We construct simple and useful approximation for the relativistic gas of massive particles. The equation of state is given by an elementary function and admits analytic solution of the Friedmann equation, including more complex cases when the relativistic gas of massive particles is considered together with radiation or with dominating cosmological constant. The model of relativistic gas may be interesting for the description of primordial Universe, especially as a candidate for the role of a Dark Matter.

Guilherme de Berredo-Peixoto; Ilya L. Shapiro; Flavia Sobreira

2005-06-16T23:59:59.000Z

130

Building Technologies Office: HVAC Optimized Heat Exchangers Research  

NLE Websites -- All DOE Office Websites (Extended Search)

Optimized Heat Optimized Heat Exchangers Research Project to someone by E-mail Share Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Facebook Tweet about Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Twitter Bookmark Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Google Bookmark Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Delicious Rank Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on Digg Find More places to share Building Technologies Office: HVAC Optimized Heat Exchangers Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research Building Envelope Research

131

Exploring the Lattice Gas Model for isoscaling  

E-Print Network (OSTI)

Isotopic spin dependent lattice gas model is used to examine if it produces the isoscaling behaviour seen in intermediate energy heavy ion collisions. Qualitative features are reproduced but quantitative agreement with experiments is lacking.

C. B. Das; S. Das Gupta

2008-06-27T23:59:59.000Z

132

Validation of a Building Simulation Tool Using Field Data for Three Identical Configuration Full-Serve Restaurants Using Different HVAC Systems  

E-Print Network (OSTI)

A new building application for a pre-existing HVAC software tool which calculates the benefits of desiccant-assisted HVAC equipment versus the performance of a standard vapor-compression system is used to model the monitored results, see Yborra...

Brillhart, P. L.; Worek, W. M.

2000-01-01T23:59:59.000Z

133

Multi-objective optimization of HVAC system with an evolutionary computation algorithm  

Science Journals Connector (OSTI)

A data-mining approach for the optimization of a HVAC (heating, ventilation, and air conditioning) system is presented. A predictive model of the HVAC system is derived by data-mining algorithms, using a dataset collected from an experiment conducted at a research facility. To minimize the energy while maintaining the corresponding IAQ (indoor air quality) within a user-defined range, a multi-objective optimization model is developed. The solutions of this model are set points of the control system derived with an evolutionary computation algorithm. The controllable input variables — supply air temperature and supply air duct static pressure set points — are generated to reduce the energy use. The results produced by the evolutionary computation algorithm show that the control strategy saves energy by optimizing operations of an HVAC system.

Andrew Kusiak; Fan Tang; Guanglin Xu

2011-01-01T23:59:59.000Z

134

Building Technologies Office: Recovery Act-Funded HVAC Research Projects  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC Research Projects to someone by E-mail HVAC Research Projects to someone by E-mail Share Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Facebook Tweet about Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Twitter Bookmark Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Google Bookmark Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Delicious Rank Building Technologies Office: Recovery Act-Funded HVAC Research Projects on Digg Find More places to share Building Technologies Office: Recovery Act-Funded HVAC Research Projects on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research Building Envelope Research Windows, Skylights, & Doors Research Space Heating & Cooling Research

135

Building Technologies Office: HVAC and Water Heater Field Tests Research  

NLE Websites -- All DOE Office Websites (Extended Search)

HVAC and Water Heater HVAC and Water Heater Field Tests Research Project to someone by E-mail Share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Facebook Tweet about Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Twitter Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Google Bookmark Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Delicious Rank Building Technologies Office: HVAC and Water Heater Field Tests Research Project on Digg Find More places to share Building Technologies Office: HVAC and Water Heater Field Tests Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research

136

Theoretical Minimum Energy Use of a Building HVAC System  

E-Print Network (OSTI)

This paper investigates the theoretical minimum energy use required by the HVAC system in a particular code compliant office building. This limit might be viewed as the "Carnot Efficiency" for HVAC system. It assumes that all ventilation and air...

Tanskyi, O.

2011-01-01T23:59:59.000Z

137

EECBG Success Story: HVAC Upgrade Saving Money, Protecting History...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Upgrade Saving Money, Protecting History EECBG Success Story: HVAC Upgrade Saving Money, Protecting History November 2, 2010 - 5:37pm Addthis A new heating and cooling system...

138

System Optimization - The Global Approach to HVAC Control  

E-Print Network (OSTI)

System Optimization is a new approach to HVAC control as implemented by Energy Management Control Systems. System Optimization is defined as electronic building control strategies which treat a building's HVAC components as a complete energy...

Thielman, D. E.

1984-01-01T23:59:59.000Z

139

Practical Approach in Design of HVAC Systems Utilizing Geothermal Energy  

Science Journals Connector (OSTI)

Geothermal is the Earth’s thermal energy. In recent years geothermal energy has been utilized for generation of electricity, heating and air conditioning (HVAC). Geothermal HVAC systems are cost effective, energy

M. Fathizadeh; D. Seims

2014-01-01T23:59:59.000Z

140

Implementation and main results Ecient Management of HVAC Systems  

E-Print Network (OSTI)

water to remove heat from the air in the building. In HVAC system equipped with chillers, the electrical #12;Motivation Implementation and main results HVAC Systems Multiple-chiller systems Heating, Ventilation and Air-Conditioning System Heating, Ventilation and Air Conditioning Systems (HVAC) represents

Schenato, Luca

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Atmospheric Environment 41 (2007) 31513160 Ozone removal by HVAC filters  

E-Print Network (OSTI)

Atmospheric Environment 41 (2007) 3151­3160 Ozone removal by HVAC filters P. Zhao, J.A. Siegel�, R May 2006; accepted 14 June 2006 Abstract Residential and commercial HVAC filters that have been loaded of the relative importance of HVAC filters as a removal mechanism for ozone in residential and commercial

Siegel, Jeffrey

142

MATERIALS AND INFORMATION FLOWS FOR HVAC DUCTWORK FABRICATION AND SITE  

E-Print Network (OSTI)

MATERIALS AND INFORMATION FLOWS FOR HVAC DUCTWORK FABRICATION AND SITE INSTALLATION Matt Holzemer,1, and air-conditioning (HVAC) systems requires a set of complex activities and handoffs between multiple architecture-, engineering-, and construction practitioners. This paper highlights one part of the HVAC

Tommelein, Iris D.

143

ThermoSense: Occupancy Thermal Based Sensing for HVAC Control  

E-Print Network (OSTI)

ThermoSense: Occupancy Thermal Based Sensing for HVAC Control Alex Beltran Elect. Eng. & Comp Occupancy Sensing, Thermal Sensing, HVAC Control 1. INTRODUCTION From 1980 to 2010, energy in the United, November 13-14 2013, Rome, Italy. Copyright 2013 ACM 978-1-4503-2431-1/13/11 ...$15.00. (HVAC) consumed 42

Cerpa, Alberto E.

144

Department of Mechanical Engineering Spring 2012 HVAC Filter Sensor -Global  

E-Print Network (OSTI)

PENNSTATE Department of Mechanical Engineering Spring 2012 HVAC Filter Sensor - Global Overview The purpose of this project is to develop a heating, ventilation, and air conditioning (HVAC) monitoring a residential, forced flow, multi-zone HVAC filter needs to be replaced, and then alerts the users

Demirel, Melik C.

145

SMUD's HVAC Programs Ravi Patel-Program Planning  

E-Print Network (OSTI)

1 SMUD's HVAC Programs 5-7-13 Ravi Patel- Program Planning Bruce Baccei- R&D #12;SMUD's Residential contractors trained and BPI certified ­ Majority were pushing only HVAC; now driving the HPP · Program encourages more HVAC replacements to occur through HPP ­ Move away from stand alone programs ­ Start

California at Davis, University of

146

Lessons Learned During HVAC Installation Dept. of Computer Science  

E-Print Network (OSTI)

Lessons Learned During HVAC Installation Ian Watson AI-CBR Dept. of Computer Science University of HVAC equipment. It has been developed as an adjunct to an existing system that uses case-based reasoning to reuse previous HVAC installation specifications and designs. The system described lets

Watson, Ian

147

An update on acoustics designs for HVAC (Engineering) K. Marriott  

E-Print Network (OSTI)

An update on acoustics designs for HVAC (Engineering) K. Marriott IOA, 29a Ashburton Road, Croydon and Air Conditioning (HVAC) engineer is to engineer ways for keeping these factors under control the HVAC engineer's environmental requirements while minimizing noise generated in the process considering

Paris-Sud XI, Université de

148

Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings  

E-Print Network (OSTI)

Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings Tom Rogg REU Student to assist HVAC has the potential to significantly reduce life cycle cost and energy consumption and electrical system that will tie thermostats to controlled valves in the actual HVAC system. Based on results

Mountziaris, T. J.

149

Monitoring-based HVAC Commissioning of an Existing Office  

E-Print Network (OSTI)

LBNL-5940E Monitoring-based HVAC Commissioning of an Existing Office Building for Energy Efficiency thereof or The Regents of the University of California. #12;1 Monitoring-based HVAC Commissioning@lbl.gov, Tel: 1-510-486-4921 Abstract The performance of Heating, Ventilation and Air Conditioning (HVAC

150

Handover Performance of HVAC Duct Based Indoor Wireless Networks  

E-Print Network (OSTI)

Handover Performance of HVAC Duct Based Indoor Wireless Networks A. E. Xhafa, P. Sonthikorn, and O in indoor wireless net- works (IWN) that use heating, ventilation, and air conditioning (HVAC) ducts.e., new call blocking and handover dropping probabilities, of an IWN that uses HVAC ducts are up to 6

Stancil, Daniel D.

151

Implementation of a Scenario-based MPC for HVAC Systems  

E-Print Network (OSTI)

Implementation of a Scenario-based MPC for HVAC Systems: an Experimental Case Study Alessandra, Ventilation and Air Conditioning (HVAC) systems play a fundamental role in maintaining acceptable thermal energy savings potential. Developing effective MPC-based control strategies for HVAC systems

Johansson, Karl Henrik

152

Continued on next page A letter explaining the 2005 HVAC  

E-Print Network (OSTI)

Continued on next page A letter explaining the 2005 HVAC Change-out to consumers is available this bulletin, or downloaded from the 2005 HVAC Change out Information website at: www.energy.ca.gov/title24 duct sealing requirements for HVAC change-outs in existing homes become effective October 1, 2005

153

Deposition of Biological Aerosols on HVAC Heat Exchangers  

E-Print Network (OSTI)

LBNL-47669 Deposition of Biological Aerosols on HVAC Heat Exchangers Jeffrey Siegel and Iain Walker of Biological Aerosols on HVAC Heat Exchangers Jeffrey A. Siegel Iain S. Walker, Ph.D. ASHRAE Student Member that are found in commercial and residential HVAC systems of 1 - 6 m/s (200 - 1200 ft/min), particle diameters

154

Tematiche di ricerca Controllo di sistemi HVAC&R  

E-Print Network (OSTI)

Tematiche di ricerca Controllo di sistemi HVAC&R Controllo di processo per l'industria dei;Tematiche di ricerca Controllo di sistemi HVAC&R Controllo di processo per l'industria dei semiconduttori controllo di sistemi HVAC&R 2 Controllo di processo per l'industria dei semiconduttori 3 Problemi di

Schenato, Luca

155

Long Range Passive UHF RFID System Using HVAC Ducts  

E-Print Network (OSTI)

INVITED P A P E R Long Range Passive UHF RFID System Using HVAC Ducts To provide a potential communications channel, HVAC ducts can function as electromagnetic waveguides; a 30-m read range has been-conditioning (HVAC) ducts as a potential communication channel between passive ultrahigh-frequency (UHF) radio

Hochberg, Michael

156

Chapter 5: Lighting, HVAC, and Plumbing  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

: Lighting, : Lighting, HVAC, and Plumbing High-Performance Engineering Design Lighting System Design Mechanical System Design Central Plant Systems Plumbing and Water Use Building Control Systems Electrical Power Systems Metering LANL | Chapter 5 High-Performance Engineering Design Lighting, HVAC, and Plumbing By now, the building envelope serves multiple roles. It protects the occupants from changing weather condi- tions and it plays a key part in meeting the occupants' comfort needs. The heating, ventilating, air-conditioning, and lighting (HVAC&L) systems complement the archi- tectural design, govern the building's operation and maintenance costs, and shape the building's long-term environmental impact. The architectural design maximizes the potential for a high-performance building, but it is the

157

A PDI for your HVAC System  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8/3/2012 Technical Approach Develop a PDI for HVAC PDI focus is on Inspecting Installation - a $10 Chinese sweatshop t-shirt gets a QA/QC sticker, why not a $10k HVAC system? Develop & require diagnostics that confirm good installations: - Air flow, duct leakage, refrigerant charge, delivered temperatures, system pressures, filter requirements, fan power, noise - On board diagnostics (OBD) for flow, pressures, fan power, charge Make it a warranty requirement, code requirement, permit requirement, etc. Recommended Guidance Develop the PDI checklist and label (include target and system test results) - External Tests: duct leaks - Internal Tests: OBD for system pressures, air flow, charge, fan power - Labels: Certify tight equipment

158

Isoscaling in the Lattice Gas Model  

E-Print Network (OSTI)

The isoscaling behavior is investigated using the isotopic/isobaric yields from the equilibrated thermal source which is prepared by the lattice gas model for lighter systems with A = 36. The isoscaling parameters $\\alpha$ and -$\\beta$ are observed to drop with temperature. The difference of neutron and proton chemical potential shows a turning point around 5 MeV where the liquid gas phase transition occurs in the model. The relative free neutron or proton density shows a nearly linear relation with the N/Z (neutron to proton ratio) of system and the isospin fractionation is observed.

Y. G. Ma; K. Wang; Y. B. Wei; G. L. Ma; X. Z. Cai; J. G. Chen; D. Q. Fang; W. Guo; W. Q. Shen; W. D. Tian; C. Zhong

2004-02-28T23:59:59.000Z

159

Natural Gas Supply in Denmark -A Model of Natural Gas Transmission and the  

E-Print Network (OSTI)

and power generators of which most are natural gas fired, leads to the natural assumption that the future the consumption of natural gas for heat and power generation is emphasized. General results and threeNatural Gas Supply in Denmark - A Model of Natural Gas Transmission and the Liberalized Gas Market

160

Research & Development Roadmap: Emerging HVAC Technologies  

Energy.gov (U.S. Department of Energy (DOE))

The Research and Development (R&D) Roadmap for Emerging Heating, Ventilation, and Air-Conditioning (HVAC) Technologies provides recommendations to the Building Technologies Office (BTO) on R&D activities to pursue that will aid in achieving BTO’s energy savings goals.

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Greenhouse Gas Training Program for Inventory and Mitigation Modeling |  

Open Energy Info (EERE)

Greenhouse Gas Training Program for Inventory and Mitigation Modeling Greenhouse Gas Training Program for Inventory and Mitigation Modeling Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Greenhouse Gas Training Program for Inventory and Mitigation Modeling Agency/Company /Organization: Future Perfect Sector: Climate Focus Area: GHG Inventory Development, Greenhouse Gas Topics: GHG inventory, Low emission development planning, -LEDS Resource Type: Case studies/examples, Training materials Website: www.gpstrategiesltd.com/divisions/future-perfect/ Country: South Korea Eastern Asia Language: English References: Greenhouse Gas Training Program for Inventory and Mitigation Modeling[1] Logo: Greenhouse Gas Training Program for Inventory and Mitigation Modeling Jointly sponsored by Greenhouse Gas Inventory & Research (GIR) Center of

162

Scaling in the Lattice Gas Model  

E-Print Network (OSTI)

A good quality scaling of the cluster size distributions is obtained for the Lattice Gas Model using the Fisher's ansatz for the scaling function. This scaling identifies a pseudo-critical line in the phase diagram of the model that spans the whole (subcritical to supercritical) density range. The independent cluster hypothesis of the Fisher approach is shown to describe correctly the thermodynamics of the lattice only far away from the critical point.

F. Gulminelli; Ph. Chomaz; M. Bruno; M. D'Agostino

2002-01-18T23:59:59.000Z

163

University of North Carolina at Charlotte Design and Construction Manual Section 2, Division 23 HVAC  

E-Print Network (OSTI)

­ HVAC SECTION 2 DIVISION 23 HVAC #12;University of North Carolina at Charlotte Design and Construction Manual Section 2, Division 23 ­ HVAC DIVISION 23 - HVAC Note: This is a guide for Designers only 23 0510 - MECHANICAL GENERAL - HVAC PART 1 - GENERAL 1.1 MECHANICAL DESIGNER: A. Design

Xie,Jiang (Linda)

164

Modelling and simulation of gas turbines  

Science Journals Connector (OSTI)

Today, gas turbines (GTs) are one of the major parts of modern industry. They have played a key role in aeronautical industry, power generation, and main mechanical drivers for large pumps and compressors. Modelling and simulation of GTs has always been a powerful tool for performance optimisation of this kind of equipment. Remarkable research activities have been carried out in this field and a variety of analytical and experimental models have been built so far to get in-depth understanding of the non-linear behaviour and complex dynamics of these systems. However, the need to develop accurate and reliable models of gas turbines for different objectives and applications has been a strong motivation for researchers to continue to work in this area. This paper focuses on major research activities which have been carried out so far in the field of modelling and simulation of gas turbines. It covers main white-box and black-box models and their applications in control systems. This study can be a good reference for current and prospective researchers who are working or planning to work in this fascinating area of research.

Hamid Asgari; XiaoQi Chen; Raazesh Sainudiin

2013-01-01T23:59:59.000Z

165

Lattice Boltzmann models for nonequilibrium gas flows  

Science Journals Connector (OSTI)

Due to its computational efficiency, the kinetic-based lattice Boltzmann method has recently been used to model nonequilibrium gas dynamics. With appropriate boundary conditions, lattice Boltzmann models have been able to capture both velocity slip and temperature jump at a solid surface. To enable these models to simulate flows in the transition regime, both high-order and modified lattice Boltzmann models have been proposed. In this paper, we demonstrate the advantages of the standard lattice Bhatnagar-Gross-Krook model in predicting high-order rarefaction phenomenon. In addition, we show that current high-order lattice Boltzmann models are not yet able to capture the nonlinear constitutive relation for the stress in the Knudsen layer, despite the improved predictions of the wall slip-velocity, especially for Poiseuille flow. By considering how the wall affects the gas mean free path, we present a simplified high-order lattice Boltzmann model that can predict flow in the transition regime and is also able to capture the essential characteristics of the Knudsen layer.

Gui-Hua Tang; Yong-Hao Zhang; David R. Emerson

2008-04-21T23:59:59.000Z

166

Laboratory measurement of secondary pollutant yields from ozone reaction with HVAC filters.  

E-Print Network (OSTI)

Ozone Reaction with HVAC Filters Hugo Destaillats, WenhaoOzone Reaction with HVAC Filters Hugo Destaillats 1,3,* ,Ozone Reaction with HVAC Filters Hugo Destaillats 1,3,* ,

Destaillats, Hugo

2012-01-01T23:59:59.000Z

167

Nuclear response beyond the Fermi gas model  

E-Print Network (OSTI)

The Fermi gas model, while providing a reasonable qualitative description of the continuum nuclear response, does not include the effects of dynamical nucleon-nucleon correlations in the initial and final states, that have long been recognized to play a critical role in specific kinematical regions. We review a many-body approach in which these effects are consistently taken into account and discuss the results of a calculation of the quasielastic neutrino-oxygen cross section as an illustrative example.

Omar Benhar

2003-07-14T23:59:59.000Z

168

HVAC Efficiency Controls Could Mean Significant Savings | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC Efficiency Controls Could Mean Significant Savings HVAC Efficiency Controls Could Mean Significant Savings HVAC Efficiency Controls Could Mean Significant Savings April 27, 2012 - 11:58am Addthis HVAC Efficiency Controls Could Mean Significant Savings April Saylor April Saylor Former Digital Outreach Strategist, Office of Public Affairs What does this mean for me? Commercial building owners could save an average 38% on their heating & cooling bills just by installing a few new controls onto their HVAC systems. According to a new report from Pacific Northwest National Lab, commercial building owners could save an average 38 percent on their heating and cooling bills just by installing a few new controls onto their HVAC systems. These findings mean significant potential savings for building owners who use commercial rooftop systems - but there's just one problem: the

169

Applications of HVAC System Utilizing Building Thermal Mass in Japan  

NLE Websites -- All DOE Office Websites (Extended Search)

Applications of HVAC System Utilizing Building Thermal Mass in Japan Applications of HVAC System Utilizing Building Thermal Mass in Japan Speaker(s): Katsuhiro Miura Date: January 27, 2012 - 10:00am Location: 90-3122 Seminar Host/Point of Contact: Michael Wetter Buildings have a large thermal capacity and it affects much on building thermal load for the HVAC system. The thermal mass can be utilized also to control the thermal load by storing thermal energy before HVAC operation. There are two ways to store thermal energy. One is by operating the HVAC system and the other is by natural ventilation, mainly at night. The latter could be combined with daily HVAC operation as a hybrid ventilation. Thermal mass storage is useful to decrease the hourly peak load and the daily thermal load and can be used for both cooling and heating purpose.

170

Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger  

NLE Websites -- All DOE Office Websites (Extended Search)

Radial Air Bearing Radial Air Bearing Heat Exchanger Research Project to someone by E-mail Share Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Facebook Tweet about Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Twitter Bookmark Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Google Bookmark Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Delicious Rank Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on Digg Find More places to share Building Technologies Office: HVAC Radial Air Bearing Heat Exchanger Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE

171

Estimates of HVAC filtration efficiency for fine and ultrafine particles of outdoor origin  

Science Journals Connector (OSTI)

Abstract This work uses 194 outdoor particle size distributions (PSDs) from the literature to estimate single-pass heating, ventilating, and air-conditioning (HVAC) filter removal efficiencies for PM2.5 and ultrafine particles (UFPs: HVAC filters identified in the literature. Filters included those with a minimum efficiency reporting value (MERV) of 5, 6, 7, 8, 10, 12, 14, and 16, as well as HEPA filters. We demonstrate that although the MERV metric defined in ASHRAE Standard 52.2 does not explicitly account for UFP or PM2.5 removal efficiency, estimates of filtration efficiency for both size fractions increased with increasing MERV. Our results also indicate that outdoor PSD characteristics and assumptions for particle density and typical size-resolved infiltration factors (in the absence of HVAC filtration) do not drastically impact estimates of HVAC filter removal efficiencies for PM2.5. The impact of these factors is greater for UFPs; however, they are also somewhat predictable. Despite these findings, our results also suggest that MERV alone cannot always be used to predict UFP or PM2.5 removal efficiency given the various size-resolved removal efficiencies of different makes and models, particularly for MERV 7 and MERV 12 filters. This information improves knowledge of how the MERV designation relates to PM2.5 and UFP removal efficiency for indoor particles of outdoor origin. Results can be used to simplify indoor air quality modeling efforts and inform standards and guidelines.

Parham Azimi; Dan Zhao; Brent Stephens

2014-01-01T23:59:59.000Z

172

gas | OpenEI  

Open Energy Info (EERE)

gas gas Dataset Summary Description The following data-set is for a benchmark residential home for all TMY3 locations across all utilities in the US. The data is indexed by utility service provider which is described by its "unique" EIA ID ( Source National Renewable Energy Laboratory Date Released April 05th, 2012 (2 years ago) Date Updated April 06th, 2012 (2 years ago) Keywords AC apartment CFL coffeemaker Computer cooling cost demand Dishwasher Dryer Furnace gas HVAC Incandescent Laptop load Microwave model NREL Residential television tmy3 URDB Data text/csv icon Residential Cost Data for Common Household Items (csv, 14.5 MiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Annually Time Period License License Open Data Commons Public Domain Dedication and Licence (PDDL)

173

SPINTHIR: An ignition model for gas turbines  

E-Print Network (OSTI)

MCS 7 Chia Laguna, Cagliari, Sardinia, Italy, September 11-15, 2011 A PRACTICAL MODEL FOR THE HIGH-ALTITUDE RELIGHT OF A GAS TURBINE COMBUSTOR A. Neophytou*,1, E. Mastorakos*, E.S. Richardson**, S. Stow*** and M. Zedda*** em257@eng... :1916-1927, 2010. [7] Naegeli, D. W. and Dodge, L. G. Combust. Sci. Technol., 80:165-184, 1991. [8] Stow, S. and Zedda, M. and Triantaffylidis, A. and Garmory, A. and Mastorakos, E. and Mosbach, T. Conditional Moment Closure LES modelling of an aero-engine...

Neophytou, A; Mastorakos, E

2012-08-28T23:59:59.000Z

174

Pitfalls in Building and HVAC Systems  

E-Print Network (OSTI)

the summer savings. ? Consider all forms of savings, not just en ergy. Opportunities are often missed be cause only energy savings are consideted. For example, the installation of extetior wall insulation or aluminum thermopane win dows result in a...PITFALLS IN BUILDING AND HVAC SYSTEMS B. N. Gidwani, P.E. Roy F. Weston, Inc. West Chester, Pennsylvania ABSTRACT The purpose of an energy audit is to identify and analyze areas of energy consumption and to pro pose methods of conservation...

Gidwani, B. N.

175

Fabrication of A Quantum Well Based System for Truck HVAC  

Energy.gov (U.S. Department of Energy (DOE))

Discusses performance differences between conventional modules and quantum well modules and details a conventional HZ-14 device, using bulk bismuth-telluride advantageous for truck HVAC applications.

176

Fault Detection and Diagnosis in Building HVAC Systems.  

E-Print Network (OSTI)

??Building HVAC systems account for more than 30% of annual energy consumption in United States. However, it has become apparent that only in a small… (more)

Najafi, Massieh

2010-01-01T23:59:59.000Z

177

The impact of filter loading on residential hvac performance.  

E-Print Network (OSTI)

??Buildings are the primary user of energy in the USA. Within homes, the heating, ventilation, and air condition (HVAC) system is the largest energy consumer.… (more)

Kruger, Abraham J.

2013-01-01T23:59:59.000Z

178

Markov Models for GP and Variablelength GAs with Homologous Crossover  

E-Print Network (OSTI)

Markov Models for GP and Variable­length GAs with Homologous Crossover Riccardo Poli School Abstract In this paper we present a Markov model for GP and variable­length GAs with homolo­ gous crossover from the parents. We obtain this result by using the core of Vose's model for GAs in conjunction

Fernandez, Thomas

179

A Scenario-based Predictive Control Approach to Building HVAC Management Systems  

E-Print Network (OSTI)

A Scenario-based Predictive Control Approach to Building HVAC Management Systems Alessandra Parisio and Air Conditioning (HVAC) systems while minimizing the overall energy use. The strategy uses

Johansson, Karl Henrik

180

Characterization of HVAC operation uncertainty in EnergyPlus AHU modules.  

E-Print Network (OSTI)

??This study addresses 5 uncertainties that exist in the operation of HVAC systems, which will presumably affect the actual energy consumption of the HVAC system… (more)

Sui, Di

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Temperature determination from the lattice gas model  

E-Print Network (OSTI)

Determination of temperature from experimental data has become important in searches for critical phenomena in heavy ion collisions. Widely used methods are ratios of isotopes (which rely on chemical and thermal equilibrium), population ratios of excited states etc. Using the lattice gas model we propose a new observable: $n_{ch}/Z$ where $n_{ch}$ is the charge multiplicity and $Z$ is the charge of the fragmenting system. We show that the reduced multiplicity is a good measure of the average temperature of the fragmenting system.

S. Das Gupta; J. Pan; M. B. Tsang

1996-09-30T23:59:59.000Z

182

HVAC filtration for controlling infectious airborne disease transmission in indoor environments: Predicting risk reductions and operational costs  

Science Journals Connector (OSTI)

Abstract This work describes and applies a methodology for estimating the impact of recirculating heating, ventilating, and air-conditioning (HVAC) particle filters on the control of size-resolved infectious aerosols in indoor environments using a modified version of the Wells-Riley model for predicting risks of infectious disease transmission. Estimates of risk reductions and associated operational costs of both HVAC filtration and equivalent outdoor air ventilation are modeled and compared using a case study of airborne transmission of influenza in a hypothetical office space. Overall, recirculating HVAC filtration was predicted to achieve risk reductions at lower costs of operation than equivalent levels of outdoor air ventilation, particularly for MERV 13–16 filters. Medium efficiency filtration products (MERV 7–11) are also inexpensive to operate but appear less effective in reducing infectious disease risks.

Parham Azimi; Brent Stephens

2013-01-01T23:59:59.000Z

183

Spherically symmetric inhomogeneous model with Chaplygin gas  

E-Print Network (OSTI)

We investigate the late time acceleration with a Chaplygin type of gas in spherically symmetric inhomogeneous model. At the early phase we get Einstien-deSitter type of solution generalised to inhomogeneous spacetime. But at late stage of the evolution our solutions admit the accelerating nature of the universe. For a large scale factor our model behaves like a ?CDM model. We calculate the deceleration parameter for this anisotropic model, which, unlike its homogeneous counterpart, shows that the flip is not syn- chronous occurring early at the outer shells. This is in line with other physical processes in any inhomogeneous models. Depending upon initial conditions our solution also gives bouncing universe. In the absence of inhomogeneity our solution reduces to wellknown solutions in homogeneous case. We have also calculated the effective deceleration parameter in terms of Hubble parameter. The whole situation is later discussed with the help of wellknown Raychaudhury equation and the results are compared with the previous case. This work is an extension of our recent communication where an attempt was made to see if the presence of extra dimensions and/or inhomogeneity can trigger an inflation in a matter dominated Lemaitre Tolman Bondi model.

D. Panigrahi; S. Chatterjee

2011-08-11T23:59:59.000Z

184

Energy efficient HVAC system features thermal storage and heat recovery  

SciTech Connect

This article describes a HVAC system designed to efficiently condition a medical center. The topics of the article include energy efficient design of the HVAC system, incentive rebate program by the local utility, indoor air quality, innovative design features, operations and maintenance, payback and life cycle cost analysis results, and energy consumption.

Bard, E.M. (Bard, Rao + Athanas Consulting Engineering Inc., Boston, MA (United States))

1994-03-01T23:59:59.000Z

185

Occupancy Based Demand Response HVAC Control Strategy Varick L. Erickson  

E-Print Network (OSTI)

Occupancy Based Demand Response HVAC Control Strategy Varick L. Erickson University of California an efficient demand response HVAC control strategy, actual room usage must be considered. Temperature and CO2 are used for simulations but not for predictive demand response strategies. In this paper, we develop

Cerpa, Alberto E.

186

HVAC & Building Management Control System Energy Efficiency Replacements  

SciTech Connect

The project objective was the replacement of an aging, un-repairable HVAC system which has grown inefficient and a huge energy consumer with low energy and efficient HVAC units, and installation of energy efficient building control technologies at City's YMCA Community Center.

Hernandez, Adriana

2012-09-21T23:59:59.000Z

187

Better Buildings Neighborhood Program Business Models Guide: Contractor/Retailer Business Models  

Energy.gov (U.S. Department of Energy (DOE))

Business models information focused on remodelers, HVAC (heating, ventilation, and air conditioning) contractors, home performance contractors, or retailers.

188

Columbia Water and Light - HVAC and Lighting Efficiency Rebates |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Columbia Water and Light - HVAC and Lighting Efficiency Rebates Columbia Water and Light - HVAC and Lighting Efficiency Rebates Columbia Water and Light - HVAC and Lighting Efficiency Rebates < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Lighting: 50% of invoiced cost up to $22,500 Program Info State Missouri Program Type Utility Rebate Program Rebate Amount HVAC Replacements: $570 - $3,770 Lighting: $300/kW reduction or half of project cost Provider Columbia Water and Light Columbia Water and Light (CWL) offers rebates to its commercial and industrial customers for the purchase of high efficiency HVAC installations and efficient lighting. Incentives for certain measures are based upon the

189

Best practices guide for residential HVAC Retrofits  

SciTech Connect

This best practices guide for residential HVAC system retrofits is aimed at contractors who want guidance on delivering energy efficient, cost effective and innovative products. It has been developed around the idea of having packages of changes to the building HVAC system and building envelope that are climate and house construction dependent. These packages include materials, procedures and equipment and are designed to remove some of the guesswork from a builder, contractor, installer or homeowner decisions about how best to carry out HVAC changes. The packages are not meant to be taken as rigid requirements--instead they are systems engineered guidelines that form the basis for energy efficient retrofits. Similar approaches have been taken previously for new construction to develop extremely energy efficient homes that are comfortable safe and durable, and often cost less than standard construction. This is best epitomized by the Building America program whose partners have built thousands of residences throughout the U.S. using these principles. The differences between retrofitting and new construction tend to limit the changes one can make to a building, so these packages rely on relatively simple and non-intrusive technologies and techniques. The retrofits also focus on changes to a building that will give many years of service to the occupants. Another key aspect of these best practices is that we need to know how a house is working so that we know what parts have the potential for improvement. To do this we have put together a set of diagnostic tools that combine physical measurements and checklists/questionnaires. The measured test results, observations and homeowner answers to questions are used to direct us towards the best retrofits applicable to each individual house. The retrofits will depend on the current condition of the building envelope and HVAC system, the local climate, the construction methods used for the house, and the presence of various energy saving systems (e.g., a Heat Recovery Ventilator) and/or materials. This is just like a doctor referring a patient for blood tests or x-rays before actually performing surgery. This way the doctor can be sure that he does the right thing. To take this analogy further--we can borrow from the medical profession and say that the first thought when retrofitting a house is to do no harm, i.e., do not make changes that could make the house worse to live in.

Walker, Iain S.

2003-08-11T23:59:59.000Z

190

VARIABLE SPEED INTEGRATED INTELLIGENT HVAC BLOWER  

SciTech Connect

This comprehensive topical report discusses the key findings in the development of an advanced blower for HVAC applications. The benefits of rearward inclined blades over that of traditional forward inclined blades is well documented, and several prototype wheels are demonstrated in various housings. A comparison of retrofitted blowers to that of three typical units from the industry is presented. The design and modification of the blower housing is addressed and the impact of size limitations on static efficiency is discussed. The roadmap to rearward-inclined wheel technology insertion is presented and typical static efficiency gains are documented.

Herman Wiegman; Charlie Stephens; Xiaoyue Liu; Ralph Carl; Sunny Zhuang; Paul Szczesny; Kamron Wright

2003-09-23T23:59:59.000Z

191

OBSERVE: Occupancy-Based System for Efficient Reduction of HVAC Energy  

E-Print Network (OSTI)

OBSERVE: Occupancy-Based System for Efficient Reduction of HVAC Energy Varick L. Erickson, Miguel Á & control General Terms Algorithms, Machine Learning, Measurement Keywords Occupancy, HVAC, Ventilation for heating, ventilation, and air-conditioning (HVAC) systems[2]. Studies suggest that 15% to 25% of HVAC

Carreira-Perpiñán, Miguel Á.

192

Duty-Cycling Buildings Aggressively: The Next Frontier in HVAC Control  

E-Print Network (OSTI)

Duty-Cycling Buildings Aggressively: The Next Frontier in HVAC Control Yuvraj Agarwal, Bharathan the dominant energy consumer is the HVAC system. Despite this fact, in most buildings the HVAC system is run sensing to guide the operation of a building HVAC system. We show how we can enable aggressive duty

Simunic, Tajana

193

Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable-Speed-Drive Chillers  

E-Print Network (OSTI)

LBNL-58636 Best Practices for Energy Efficient Cleanrooms Efficient HVAC Systems: Variable Efficient Cleanrooms Efficient HVAC Water Systems: Variable-Speed-Drive Chillers Tengfang Xu Contents HVAC.................................................................................................................................... 6 #12;HVAC Water Systems Variable-Speed-Drive Chillers Summary Cleanroom energy benchmarking data

194

Evaluation of HVAC filters as a sampling mechanism for indoor microbial communities  

E-Print Network (OSTI)

Evaluation of HVAC filters as a sampling mechanism for indoor microbial communities Federico Noris Fungi Microbial community HVAC filter Settled dust Air a b s t r a c t HVAC filters are in place of bacterial and fungal concentrations and communities in HVAC filter dust and other sampling locations

Siegel, Jeffrey

195

Loop Gas Model for Open Strings  

E-Print Network (OSTI)

The open string with one-dimensional target space is formulated in terms of an SOS, or loop gas, model on a random surface. We solve an integral equation for the loop amplitude with Dirichlet and Neumann boundary conditions imposed on different pieces of its boundary. The result is used to calculate the mean values of order and disorder operators, to construct the string propagator and find its spectrum of excitations. The latter is not sensible neither to the string tension $\\L$ nor to the mass $\\mu$ of the ``quarks'' at the ends of the string. As in the case of closed strings, the SOS formulation allows to construct a Feynman diagram technique for the string interaction amplitudes.

V. Kazakov; I. Kostov

1992-05-18T23:59:59.000Z

196

COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM  

SciTech Connect

In this paper, a hotel with hybrid geothermal heat pump system (HyGSHP) in the Pensacola is selected and simulated by the transient simulation software package TRNSYS [1]. To verify the simulation results, the validations are conducted by using the monthly average entering water temperature, monthly facility consumption data, and etc. And three types of HVAC systems are compared based on the same building model and HVAC system capacity. The results are presented to show the advantages and disadvantages of HyGSHP compared with the other two systems in terms of energy consumptions, life cycle cost analysis.

Jiang Zhu; Yong X. Tao

2011-11-01T23:59:59.000Z

197

Warming impact on energy use of HVAC system in buildings of different thermal qualities and in different climates  

Science Journals Connector (OSTI)

Abstract In order to combat climate change, energy use in the building must be further reduced. Heating ventilation and air conditioning (HVAC) systems in residential buildings account for considerable fraction of global energy consumption. The potential contribution the domestic sector can make in reducing energy consumption is recognized worldwide. The driving energy of \\{HVACs\\} depends on the thermal quality of the building envelope (TQBE) and outside temperature. Definitely, building regulations are changing with the time toward reduce the thermal loads of buildings. However, most of the existing residential buildings were built to lower TQBE. For instant, 72% of residential dwellings in the 15-EU were built before 1972. To investigate the impact of warming on driving energy of \\{HVACs\\} of a residential building a computer model was developed. Three climate categories/cities were considered, i.e. Stockholm (cold), Istanbul (mild), and Doha (hot). In each city, two buildings were modeled: one was assumed to be built according to the current local buildings regulations (standard TQBE), while the anther was built to lower TQBE. The simulations were run for present and future (in 2050) outdoor designing conditions. The calculations show that the impact of the warming on annual driving energy of \\{HVACs\\} (reduction or increase) depends very much on the climate category and on the TQBE. Based on the climate and TQBE, the change in annual \\{HVACs\\} energy varies from ?7.4% (in cold climate) to 12.7% (in hot climate). In mild climate, it was shown that the warming does not have significant impact on annual \\{HVACs\\} energy. Improving the TQBE can mitigate the impact of the warming.

Mohamad Kharseh; Lobna Altorkmany; Mohammed Al-Khawaj; Ferri Hassani

2014-01-01T23:59:59.000Z

198

Critical-like behavior in a lattice gas model  

E-Print Network (OSTI)

ALADIN multifragmentation data show features characteristic of a critical behavior, which are very well reproduced by a bond percolation model. This suggests, in the context of the lattice gas model, that fragments are formed at nearly normal nuclear densities and temperatures corresponding to the Kertesz line. Calculations performed with a lattice gas model have shown that similarly good reproduction of the data can also be achieved at lower densities, particularly in the liquid-gas coexistence region.

A. Wieloch; J. Brzychczyk; J. Lukasik; P. Pawlowski; T. Pietrzak; W. Trautmann

2010-03-14T23:59:59.000Z

199

LDV HVAC Model Development and Validation  

Energy.gov (U.S. Department of Energy (DOE))

2011 DOE Hydrogen and Fuel Cells Program, and Vehicle Technologies Program Annual Merit Review and Peer Evaluation

200

HOMOGENEOUS MODELS IN GENERAL RELATIVITY AND GAS DYNAMICS  

E-Print Network (OSTI)

HOMOGENEOUS MODELS IN GENERAL RELATIVITY AND GAS DYNAMICS O. I. BOGOYAVLENSKII AND S. P. NOVIKOV analytically) in general relativity and gas dynamics. The investigation of these models is carried out begins with a short survey of results on non-trivial models (that is, those that are not integrable

Novikov, Sergei Petrovich

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Rock-physics Models for Gas-hydrate Systems Associated  

E-Print Network (OSTI)

Rock-physics Models for Gas-hydrate Systems Associated with Unconsolidated Marine Sediments Diana associated with unconsolidated marine sediments. The goals are to predict gas-hydrate concentration from intercalated with unconsolidated sediments. We show that the geometrical details of how gas hy- drates

Texas at Austin, University of

202

Index to Evaluate Energy Efficiency of the Building HVAC System  

E-Print Network (OSTI)

1An Index to Evaluate Energy Efficiency of the Entire Building HVAC System Presented by Dr. Claridge Date: 09/15/2014 ESL-IC-14-09-15 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14..., Beijing, China, September 14-17, 2014 3• Why we need the Energy/Load Ratio 1. Building 2. HVAC Systems 3. Common Index • Building sector consumes 40% of total energy usage in US (Residential buildings – 22%, Commercial building – 19%) • HVAC systems...

Wang, L.; Wang, L.; Claridge,D.

2014-01-01T23:59:59.000Z

203

Heat recovery and the economizer for HVAC systems  

SciTech Connect

This articles examines why a combined heat reclaim/economizer system with priority to heat reclaim operation is most likely to result in the least annual total HVAC energy. PC-based, hour-by-hour simulation programs evaluate annual HVAC energy requirements when using combined operation of heat reclaim and economizer cycle, while giving priority to operation of either one. These simulation programs also enable the design engineer to select the most viable heat reclaim and/or economizer system for any given type of HVAC system serving the building internal load level, building geographical location and other building/system variables.

Anantapantula, V.S. (Emerson Electric Co., St. Louis, MO (United States). Alco Controls Div.); Sauer, H.J. Jr. (Univ. of Missouri, Rolla, MO (United States))

1994-11-01T23:59:59.000Z

204

Comparisons of HVAC Simulations between EnergyPlus and DOE-2.2 for Data Centers  

SciTech Connect

This paper compares HVAC simulations between EnergyPlus and DOE-2.2 for data centers. The HVAC systems studied in the paper are packaged direct expansion air-cooled single zone systems with and without air economizer. Four climate zones are chosen for the study - San Francisco, Miami, Chicago, and Phoenix. EnergyPlus version 2.1 and DOE-2.2 version 45 are used in the annual energy simulations. The annual cooling electric consumption calculated by EnergyPlus and DOE-2.2 are reasonablely matched within a range of -0.4percent to 8.6percent. The paper also discusses sources of differences beween EnergyPlus and DOE-2.2 runs including cooling coil algorithm, performance curves, and important energy model inputs.

Hong, Tianzhen; Sartor, Dale; Mathew, Paul; Yazdanian, Mehry

2008-08-13T23:59:59.000Z

205

Modeling of Fission Gas Release in UO2  

SciTech Connect

A two-stage gas release model was examined to determine if it could provide a physically realistic and accurate model for fission gas release under Prometheus conditions. The single-stage Booth model [1], which is often used to calculate fission gas release, is considered to be oversimplified and not representative of the mechanisms that occur during fission gas release. Two-stage gas release models require saturation at the grain boundaries before gas is release, leading to a time delay in release of gases generated in the fuel. Two versions of a two-stage model developed by Forsberg and Massih [2] were implemented using Mathcad [3]. The original Forsbers and Massih model [2] and a modified version of the Forsberg and Massih model that is used in a commercially available fuel performance code (FRAPCON-3) [4] were examined. After an examination of these models, it is apparent that without further development and validation neither of these models should be used to calculate fission gas release under Prometheus-type conditions. There is too much uncertainty in the input parameters used in the models. In addition. the data used to tune the modified Forsberg and Massih model (FRAPCON-3) was collected under commercial reactor conditions, which will have higher fission rates relative to Prometheus conditions [4].

MH Krohn

2006-01-23T23:59:59.000Z

206

Unusual HVAC challenges require innovative solutions  

SciTech Connect

There were many reasons behind Motorola`s decision to build the first 225,000 sq ft of a planned one million sq ft manufacturing facility in Chihuahua, Mexico. Among these were the availability of skilled labor in the area, lower construction costs, some export tax advantages, and the close proximity to the US border. The new facility is made up of a variety of functional areas that together create an impressively efficient plant. Phase 1 construction included a large manufacturing floor, shipping and receiving areas, a bulk storage facility, and a large office area with a view of the factory floor. The structure also houses a retail store where Motorola consumer products are sold, a conference and banquet center, a commercial kitchen, and dining facilities for 750. The design cooling load is 750 tons; the heating load is 4.5 million Btuh. The paper discusses the challenging location, the HVAC system, and the future expansion planned.

Jardine, G.M.; Gwin, O.D. [Heery International, Inc., Atlanta, GA (United States)

1998-02-01T23:59:59.000Z

207

Connexus Energy - Residential Efficient HVAC Rebate Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Connexus Energy - Residential Efficient HVAC Rebate Program Connexus Energy - Residential Efficient HVAC Rebate Program Connexus Energy - Residential Efficient HVAC Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Heat Pumps Program Info Expiration Date 12/31/2013 State Minnesota Program Type Utility Rebate Program Rebate Amount Air Source Heat Pumps: $480 - $630 Ductless Heat Pump: $150 Geothermal Heat Pump: $200/ton Provider Connexus Energy Connexus Energy offers rebates for residential customers to improve the energy efficiency of homes. Rebates are available for air source heat pumps, ductless heat pumps and ground-source heat pumps. Equipment must meet all efficiency standards listed on the web site, and must be installed by a certified HVAC contractor. Contact Connexus Energy for other program

208

A Web Based CBR System for HVAC Sales Support  

Science Journals Connector (OSTI)

This paper describes the implementation of a CBR system to support HVAC sales staff operating in remote locations. The ... the world wide web and uses the new standard of XML as a communications protocol between....

Dan Gardingen; Ian Watson

1999-01-01T23:59:59.000Z

209

HVAC Cabinet Air Leakage Test Method- Building America Top Innovation  

Energy.gov (U.S. Department of Energy (DOE))

This 2014 Top Innovation describes Building America research that resulted in the development of an ASHRAE standard and standardized testing method for testing the air leakage of HVAC air handlers and furnace cabinets.

210

Review of Residential Low-Load HVAC Systems  

SciTech Connect

In support of the U.S. Department of Energy’s (DOE’s) Building America Program, Pacific Northwest National Laboratory (PNNL) conducted an investigation to inventory commercially available HVAC technologies that are being installed in low-load homes. The first step in this investigation was to conduct a review of published literature to identify low-load HVAC technologies available in the United States and abroad, and document the findings of existing case studies that have evaluated the performance of the identified technologies. This report presents the findings of the literature review, identifies gaps in the literature or technical understanding that must be addressed before low-load HVAC technologies can be fully evaluated, and introduces PNNL’s planned research and analysis for this project to address identified gaps and potential future work on residential low-load HVAC systems.

Brown, Scott A.; Thornton, Brian; Widder, Sarah H.

2013-09-01T23:59:59.000Z

211

Building HVAC Control System Interaction Issues: Two Case Studies  

E-Print Network (OSTI)

Direct Digital Control (DDC) allows HVAC equipment to be controlled at an upper level (supervisory control) through commands from a central system, or at a lower-level (local-loop control) by local controllers. The various levels of equipment...

Chen, Q.; Deng, S.; Toole, C.; Xu, C.

2007-01-01T23:59:59.000Z

212

Columbia Water and Light- Residential HVAC Rebate Program  

Energy.gov (U.S. Department of Energy (DOE))

Columbia Water and Light (CWL) provides an HVAC incentive for residential customers that are replacing an older heating and cooling system. Customers should submit the mechanical permit from a...

213

Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics  

E-Print Network (OSTI)

Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate...

Graham, E. L.

1980-01-01T23:59:59.000Z

214

EECBG Success Story: HVAC Upgrade Saving Money, Protecting History  

Energy.gov (U.S. Department of Energy (DOE))

With financial support from a $250,000 PA Conservation Works! grant – funded through the federal Energy Efficiency and Conservation Block Grant program and the Recovery Act – CCHS purchased a new Desert-Aire HVAC system. Learn more.

215

Deposition of biological aerosols on HVAC heat exchangers  

SciTech Connect

Many biologically active materials are transported as bioaerosols 1-10 {micro}m in diameter. These particles can deposit on cooling and heating coils and lead to serious indoor air quality problems. This paper investigates several of the mechanisms that lead to aerosol deposition on fin and tube heat exchangers. A model has been developed that incorporates the effects of several deposition mechanisms, including impaction, Brownian and turbulent diffusion, turbophoresis, thermophoresis, diffusiophoresis, and gravitational settling. The model is applied to a typical range of air velocities that are found in commercial and residential HVAC systems 1 - 6 m/s (200 - 1200 ft/min), particle diameters from 1 - 8 {micro}m, and fin spacings from 3.2 - 7.9 fins/cm (8 - 16 fins/inch or FPI). The results from the model are compared to results from an experimental apparatus that directly measures deposition on a 4.7 fins/cm (12 FPI) coil. The model agrees reasonably well with this measured data and suggests that cooling coils are an important sink for biological aerosols and consequently a potential source of indoor air quality problems.

Siegel, Jeffrey; Walker, Ian

2001-09-01T23:59:59.000Z

216

Comfort by Design: An Introduction to HVAC's Variable Refrigerant Flow (VRF) Technology  

E-Print Network (OSTI)

Comfort by Design An Introduction to HVAC’s Variable Refrigerant Flow (VRF) Technology Keith Reihl kreihl@hvac.mea.com ESL-KT-14-11-13 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 HVAC Market Overview 0% 27% 9% 5% 4... Through Efficiency Conference, Dallas, Texas Nov. 18-20 How LOUD is a traditional HVAC unit? 33 dB(A) Library 50 dB(A) Refrigerator 60 dB(A) Conversation 78 dB(A) Vacuum 25 dB(A) Recording Studio 65-75 dB(A) Residential 3-ton HVAC Unit How Q IET are VRF...

Reihl,K.

2014-01-01T23:59:59.000Z

217

The National Energy Modeling System: An Overview 1998 - Natural Gas  

Gasoline and Diesel Fuel Update (EIA)

NATURAL GAS TRANSMISSION AND DISTRIBUTION MODULE NATURAL GAS TRANSMISSION AND DISTRIBUTION MODULE blueball.gif (205 bytes) Annual Flow Submodule blueball.gif (205 bytes) Capacity Expansion Submodule blueball.gif (205 bytes) Pipeline Tariff Submodule blueball.gif (205 bytes) Distributor Tariff Submodule The natural gas transmission and distribution module (NGTDM) is the component of NEMS that represents the natural gas market. The NGTDM models the natural gas transmission and distribution network in the lower 48 States, which links suppliers (including importers) and consumers of natural gas. The module determines regional market-clearing prices for natural gas supplies (including border prices) and end-use consumption. The NGTDM has four primary submodules: the annual flow submodule, the capacity expansion submodule, the pipeline tariff submodule, and the

218

Interacting holographic generalized Chaplygin gas model  

E-Print Network (OSTI)

In this paper we consider a correspondence between the holographic dark energy density and interacting generalized Chaplygin gas energy density in FRW universe. Then we reconstruct the potential of the scalar field which describe the generalized Chaplygin cosmology.

M. R. Setare

2007-08-01T23:59:59.000Z

219

Endogenous production capacity investment in natural gas market equilibrium models  

Science Journals Connector (OSTI)

Abstract The large-scale natural gas equilibrium model applied in Egging, 2013 combines long-term market equilibria and investments in infrastructure while accounting for market power by certain suppliers. Such models are widely used to simulate market outcomes given different scenarios of demand and supply development, environmental regulations and investment options in natural gas and other resource markets. However, no model has so far combined the logarithmic production cost function commonly used in natural gas models with endogenous investment decisions in production capacity. Given the importance of capacity constraints in the determination of the natural gas supply, this is a serious shortcoming of the current literature. This short note provides a proof that combining endogenous investment decisions and a logarithmic cost function yields a convex minimization problem, paving the way for an important extension of current state-of-the-art equilibrium models.

Daniel Huppmann

2013-01-01T23:59:59.000Z

220

Section 38 - HVAC (Heating, Ventilation, Air Conditioning)  

Science Journals Connector (OSTI)

The term HVAC is an acronym for Heating, Ventilation (and) Air Conditioning, the industry term for any of various efforts to control conditions in a building or other enclosed area to improve comfort and efficiency. A closely related section is Refrigeration, which follows this one. Some contemporary HVAC techniques have ancient roots. Early forms of central heating and solar home heating were in use in Rome in the first century A.D. The earliest use of glass in windows (as opposed to a covering of wood, cloth, or hide, or simply an opening) is also attributed to the Romans at this same time. The first known use of solar-oriented building design in North America dates back to about the year 1050; i.e., the cliff dwellings built by the Anasazi (Ancient Pueblo) people of the Colorado Plateau area. Geothermal district heating was employed as early as the 1300s, in the Auvergne region of southern France. The foundation for modern central heating was established in the 1700s, first in England and then in France. The 1800s saw significant advances in the use of water heaters, especially the first automatic storage water heater (Edwin Ruud, 1889) and the first commercial solar water heater (Clarence Kemp, 1891). In comparison with heating, cooling technology was late in developing. The first successful method of producing ice occurred in 1851, and it was not until 1902 that Willis Haviland Carrier designed the first industrial air-conditioning system. His Carrier Air Conditioning Corporation would go on to develop air-conditioning systems for stores and theaters (1924) and for residential buildings (1928). Carrier remains the global leader in air conditioner production. The first air-conditioned automobile was produced by Packard in 1939. Recent entries in this section emphasize the use of alternative energy sources in heating and cooling, such as solar, photovoltaic, geothermal, and fuel cells. These advances include the ground-source heat pump, the Trombe wall, the heat pipe, and the PV/thermal hybrid system.

Cutler J. Cleveland; Christopher Morris

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Report on HVAC option selections for a relocatable classroom energy and indoor environmental quality field study  

SciTech Connect

It is commonly assumed that efforts to simultaneously develop energy efficient building technologies and to improve indoor environmental quality (IEQ) are unfeasible. The primary reason for this is that IEQ improvements often require additional ventilation that is costly from an energy standpoint. It is currently thought that health and productivity in work and learning environments requires adequate, if not superior, IEQ. Despite common assumptions, opportunities do exist to design building systems that provide improvements in both energy efficiency and IEQ. This report outlines the selection of a heating, ventilation, and air conditioning (HVAC) system to be used in demonstrating such an opportunity in a field study using relocatable school classrooms. Standard classrooms use a common wall mounted heat pump HVAC system. After reviewing alternative systems, a wall-mounting indirect/direct evaporative cooling system with an integral hydronic gas heating is selected. The anticipated advantages of this system include continuous ventilation of 100 percent outside air at or above minimum standards, projected cooling energy reductions of about 70 percent, inexpensive gas heating, improved airborne particle filtration, and reduced peak load electricity use. Potential disadvantages include restricted climate regions and possible increases in indoor relative humidity levels under some conditions.

Apte, Michael G.; Delp, Woody W.; Diamond, Richard C.; Hodgson, Alfred T.; Kumar, Satish; Rainer, Leo I.; Shendell, Derek G.; Sullivan, Doug P.; Fisk, William J.

2001-10-11T23:59:59.000Z

222

Empirical Math Model: Ideal Gas Law | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Empirical Math Model: Ideal Gas Law Empirical Math Model: Ideal Gas Law Empirical Math Model: Ideal Gas Law January 29, 2013 - 9:54am Addthis What are the key facts? Empirical models are generally most useful in describing conditions close to the experiments used to develop or calibrate them. Predictive tools are essential to understanding phenomena that can not be described experimentally, like used fuel behavior over thousands of years in a repository. Predictability is measured by understanding errors where they are introduced as well as to what degree they are quantified. To appreciate the distinction between curve fitting and what it means for a tool to be truly predictive it might help to consider how the ideal gas law was developed. In 1663, Robert Boyle performed a series of experiments at room temperature

223

Empirical Math Model: Ideal Gas Law | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Empirical Math Model: Ideal Gas Law Empirical Math Model: Ideal Gas Law Empirical Math Model: Ideal Gas Law January 29, 2013 - 9:54am Addthis What are the key facts? Empirical models are generally most useful in describing conditions close to the experiments used to develop or calibrate them. Predictive tools are essential to understanding phenomena that can not be described experimentally, like used fuel behavior over thousands of years in a repository. Predictability is measured by understanding errors where they are introduced as well as to what degree they are quantified. To appreciate the distinction between curve fitting and what it means for a tool to be truly predictive it might help to consider how the ideal gas law was developed. In 1663, Robert Boyle performed a series of experiments at room temperature

224

A Lattice Boltzmann model for diffusion of binary gas mixtures  

E-Print Network (OSTI)

used. This is fundamentally unsuitable for extension to multi-component systems containing gases of differing molecular masses that are modelled with the ideal gas equation of state. Also, existing methods for implementing boundary conditions...

Bennett, Sam

2010-10-12T23:59:59.000Z

225

Multiscale, Multiphysics Network Modeling of Shale Matrix Gas Flows  

Science Journals Connector (OSTI)

We present a pore network model to determine the permeability of shale gas matrix. Contrary to the conventional reservoirs, ... morphology of the pores, the permeability in shale depends on pressure as well. In a...

Ayaz Mehmani; Maša Prodanovi?; Farzam Javadpour

2013-09-01T23:59:59.000Z

226

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review ...  

Energy Savers (EERE)

HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review HVAC, Water Heater and Appliance R&D - 2014 BTO Peer Review Presenter: Tony Bouza, U.S. Department of Energy This...

227

Airborne Particulate Matter in HVAC Systems and its Influence on Indoor Air Quality  

E-Print Network (OSTI)

This paper first reviews the mechanisms governing movement of PMs in HVAC systems. Then, the basic equations governing PM deposition in ducts are introduced and investigations on airborne PMs distribution in HVAC systems are reviewed. The influence...

Fu, Z.; Li, N.; Wang, H.

2006-01-01T23:59:59.000Z

228

Building America Whole-House Solutions for New Homes: HVAC Design...  

Energy Savers (EERE)

HVAC Design Strategy for a Hot-Humid Production Builder Building America Whole-House Solutions for New Homes: HVAC Design Strategy for a Hot-Humid Production Builder In this...

229

CoolCab Thermal Load Reduction Project: CoolCalc HVAC Tool Development...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Thermal Load Reduction Project: CoolCalc HVAC Tool Development CoolCab Thermal Load Reduction Project: CoolCalc HVAC Tool Development 2010 DOE Vehicle Technologies and Hydrogen...

230

Direct Digital Control- A Tool for Energy Management of HVAC Systems  

E-Print Network (OSTI)

Direct digital control (DDC) applied to heating, ventilating, and air-conditioning (HVAC) systems corrects many of the deficiencies of conventional automatic temperature control systems. By applying new control sequences, DDC optimizes HVAC energy...

Swanson, K.

231

TITLE: HVAC TESTING & BALANCING FOR MAJOR AND MINOR PROJECTS OBJECTIVE AND  

E-Print Network (OSTI)

TITLE: HVAC TESTING & BALANCING FOR MAJOR AND MINOR PROJECTS OBJECTIVE AND PURPOSE: To provide an independent test & balance for the adjustment of all HVAC systems in all major projects and minor projects

Fernandez, Eduardo

232

Uncertainties in Achieving Energy Savings from HVAC Maintenance Measures in the Field  

E-Print Network (OSTI)

Uncertainties in Achieving Energy Savings from HVAC Maintenance Measures in the Field Kristin utilities across the nation to include HVAC maintenance measures in energy efficiency programs Maintenance measures have a significant potential for energy savings in residential and commercial unitary

California at Davis, University of

233

Thermodynamical Consistency of Excluded Volume Hadron Gas Models  

E-Print Network (OSTI)

The new excluded volume hadron gas model by Singh et al. [1-7] is critically discussed. We demonstrate that in this model the results obtained from relations between thermodynamical quantities disagree with the corresponding results obtained by statistical ensemble averaging. Thus, the model does not satisfy the requirements of thermodynamical consistency.

M. I. Gorenstein

2012-05-08T23:59:59.000Z

234

Modeling gas flow through microchannels and nanopores Subrata Roya)  

E-Print Network (OSTI)

Modeling gas flow through microchannels and nanopores Subrata Roya) and Reni Raju Computational. A two-dimensional finite-element based microscale flow model is developed to efficiently predict is modeled using either the continuum or the molecular approach.1­4 The con- tinuum approach solves

Roy, Subrata

235

Chapter 19: HVAC Controls (DDC/EMS/BAS) Evaluation Protocol  

SciTech Connect

The HVAC Controls Evaluation Protocol is designed to address evaluation issues for direct digital controls/energy management systems/building automation systems (DDC/EMS/BAS) that are installed to control heating, ventilation, and air-conditioning (HVAC) equipment in commercial and institutional buildings. (This chapter refers to the DDC/EMS/BAS measure as HVAC controls.) This protocol may also be applicable to industrial facilities such as clean rooms and labs, which have either significant HVAC equipment or spaces requiring special environmental conditions. This protocol addresses only HVAC-related equipment and the energy savings estimation methods associated with installing such control systems as an energy efficiency measure. The affected equipment includes: Air-side equipment (air handlers, direct expansion systems, furnaces, other heating- and cooling-related devices, terminal air distribution equipment, and fans); Central plant equipment (chillers, cooling towers, boilers, and pumps). These controls may also operate or affect other end uses, such as lighting, domestic hot water, irrigation systems, and life safety systems such as fire alarms and other security systems. Considerable nonenergy benefits, such as maintenance scheduling, system component troubleshooting, equipment failure alarms, and increased equipment lifetime, may also be associated with these systems. When connected to building utility meters, these systems can also be valuable demand-limiting control tools. However, this protocol does not evaluate any of these additional capabilities and benefits.

Romberger, J.

2014-11-01T23:59:59.000Z

236

Issue #3: HVAC Proper Installation Energy Savings: Over-Promising or Under-Delivering?  

Office of Energy Efficiency and Renewable Energy (EERE)

What energy savings are realistically achievable by following quality installation standards for installation, operation, and maintenance of residential HVAC?

237

No more gas from Egypt? Modeling offshore discoveries and import uncertainty of natural gas in Israel  

Science Journals Connector (OSTI)

Abstract Israel depends on natural gas imports from Egypt for about 40% of its domestic needs, with the remaining met from domestic production. Gas supplies from Egypt have been erratic since their initiation: disruptions have increased after the 2011 revolution in Egypt and have been further ignited by public discontent. Despite these developments, Israeli policy makers have viewed the Egyptian gas deal as a positive factor in preserving peace with Egypt and have had no better alternatives than relying upon it. This has changed, however, after recent discoveries of three major offshore fields that are expected to satisfy domestic demand for an indefinite period and to provide gas for exports. We use an extended global CGE modeling framework that incorporates multiple households and factor ownership to investigate the effects of reduced gas imports from Egypt and the evolvement of domestic gas production as an alternative. In case of reduced gas imports from Egypt, the Israeli economy would slightly retract mainly due to lower production in energy intensive sectors. Poor households would be the most negatively affected, due to the strongest relative decline in income and the strongest increase of their consumer price index. In the case of increasing domestic gas production, Israeli GDP and domestic absorption would rise by about 0.2% and 0.4%, respectively. Poor households would be more positively affected than rich ones due to their composition of factor income and their higher expenditure shares for energy intensive commodities.

Khalid Siddig; Harald Grethe

2014-01-01T23:59:59.000Z

238

Sentinel: Occupancy Based HVAC Actuation using Existing WiFi Infrastructure within Commercial Buildings  

E-Print Network (OSTI)

Sentinel: Occupancy Based HVAC Actuation using Existing WiFi Infrastructure within Commercial.agarwal@cs.cmu.edu ABSTRACT Commercial buildings contribute to 19% of the primary energy consumption in the US, with HVAC systems accounting for 39.6% of this usage. To reduce HVAC energy use, prior studies have pro- posed using

Gupta, Rajesh

239

Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond  

E-Print Network (OSTI)

Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond Lawrence Berkeley of the commissioning of HVAC systems. The approach is based on software that generates a sequence of test signals for new and retrofit projects. Introduction The performance of many HVAC systems is limited more by poor

Diamond, Richard

240

Co-simulation for performance prediction of integrated building and HVAC systems -An analysis of solution  

E-Print Network (OSTI)

Co-simulation for performance prediction of integrated building and HVAC systems - An analysis performance simulation of buildings and heating, ventilation and air- conditioning (HVAC) systems can help, heating, ventilation and air-conditioning (HVAC) systems are responsible for 10%-60% of the total building

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Theoretical Estimates of HVAC Duct Channel Capacity for High-Speed Internet Access  

E-Print Network (OSTI)

Theoretical Estimates of HVAC Duct Channel Capacity for High-Speed Internet Access Ariton E. Xhafa-conditioning (HVAC) ducts based on multi-carrier transmission that uses M-QAM mod- ulation and measured channel- flections in HVAC ducts). Our work also shows that data rates in excess of 300 Mbps are possible over

Stancil, Daniel D.

242

Multi-carrier Signal Transmission through HVAC Ducts: Experimental Results for Channel Capacity  

E-Print Network (OSTI)

Multi-carrier Signal Transmission through HVAC Ducts: Experimental Results for Channel Capacity, for the first time, experimental results on channel capacity of heating, ventilation, and air-conditioning (HVAC through a building HVAC duct system demonstrate the ability to transmit with a spectral efficiency of 3

Stancil, Daniel D.

243

Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture  

E-Print Network (OSTI)

Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture Ariton E. Xhafa, Paisarn-- In this paper, we present an innovative solution to the handover problem in multi-story buildings using HVAC of the indoor wireless networks that use the heating, ventilation, and air conditioning (HVAC) ducts

Stancil, Daniel D.

244

Comparison of HVAC filter test methods for particle removal efficiency Brent Stephens1,*  

E-Print Network (OSTI)

Comparison of HVAC filter test methods for particle removal efficiency Brent Stephens1,* , Jeffrey Introduction The use of HVAC filters in buildings is one strategy to reduce occupant exposure to particulate matter. However, HVAC filters are typically tested only in laboratory settings and little is known about

Siegel, Jeffrey

245

Conventional Facilities Chapter 6: HVAC Systems 6-1 NSLS-II Preliminary Design Report  

E-Print Network (OSTI)

Conventional Facilities Chapter 6: HVAC Systems 6-1 NSLS-II Preliminary Design Report 6 MECHANICAL ­ HVAC SYSTEMS 6.1 Design Criteria 6.1.1 Codes and Standards The latest edition of the codes, standards have adequate capacity and head, no chilled water pumps #12;Conventional Facilities Chapter 6: HVAC

Ohta, Shigemi

246

RF propagation in an HVAC duct system: impulse response characteristics of the channel  

E-Print Network (OSTI)

RF propagation in an HVAC duct system: impulse response characteristics of the channel Pavel V, the heating, ventilation, and air conditioning (HVAC) duct system in buildings is a complex network of hollow at RF and microwave frequencies of com- mon interest. HVAC ducts can be used as a wireless communication

Stancil, Daniel D.

247

VOLUME 16, NUMBER 3 HVAC&R RESEARCH MAY 2010 The Effects of Filtration on  

E-Print Network (OSTI)

VOLUME 16, NUMBER 3 HVAC&R RESEARCH MAY 2010 273 The Effects of Filtration on Pressure Drop and Energy Consumption in Residential HVAC Systems (RP-1299) Brent Stephens Atila Novoselac, PhD Jeffrey A of high-efficiency HVAC filters is a common strategy to control exposure to airborne particulate matter

Siegel, Jeffrey

248

EVALUATION OF EMERGING DIAGNOSTIC TOOLS FOR COMMERCIAL HVAC SYSTEMS Hannah Friedman Mary Ann Piette  

E-Print Network (OSTI)

EVALUATION OF EMERGING DIAGNOSTIC TOOLS FOR COMMERCIAL HVAC SYSTEMS Hannah Friedman Mary Ann Piette for commercial HVAC systems. We present a brief description of the diagnostic tools, and then focus on evaluating, ventilating, and air-conditioning (HVAC) systems (Gregerson, 1997, Claridge et al., 2000). If these energy

249

Fuzzy Rule Reduction and Tuning of Fuzzy Logic Controllers for a HVAC System  

E-Print Network (OSTI)

Fuzzy Rule Reduction and Tuning of Fuzzy Logic Controllers for a HVAC System R. Alcal´a, J. Alcal, Ventilating and Air Conditioning (HVAC) Systems are equip- ments usually implemented for maintaining satisfactory comfort conditions in build- ings. The design of Fuzzy Logic Controllers (FLCs) for HVAC Systems

Granada, Universidad de

250

RoomZoner: Occupancy-based Room-Level Zoning of a Centralized HVAC System  

E-Print Network (OSTI)

RoomZoner: Occupancy-based Room-Level Zoning of a Centralized HVAC System Tamim Sookoor & Kamin. In this paper we present a CPS that enables a centralized Heating, Ventila- tion, and Air Conditioning (HVAC application due to residential HVAC systems ac- counting for over 15% of all U.S. energy usage, making it one

Whitehouse, Kamin

251

Comparison of dust from HVAC filters, indoor surfaces, and indoor air Federico Noris*  

E-Print Network (OSTI)

Comparison of dust from HVAC filters, indoor surfaces, and indoor air Federico Noris* , Kerry A and Environmental Engineering * Corresponding email: Fedenoris@mail.utexas.edu SUMMARY HVAC filters are long heavy metal (Pb, Cd and As) concentrations. HVAC filter microbial concentrations appear to be consistent

Siegel, Jeffrey

252

Occupancy Modeling and Prediction for Building Energy Management VARICK L. ERICKSON, University of California, Merced  

E-Print Network (OSTI)

(ASHRAE) comfort standards. Categories and Subject Descriptors: I.6.5 [Simulation and Modeling]: Model Additional Key Words and Phrases: Occupancy, HVAC, ventilation, energy savings, demand response, machine-conditioning (HVAC) systems [EIA 2010]. Studies suggest that 15% to 25% of HVAC energy can be saved by setting

Carreira-Perpiñán, Miguel Á.

253

Occupancy Modeling and Prediction for Building Energy Varick L. Erickson, University of California, Merced  

E-Print Network (OSTI)

) comfort standards. Categories and Subject Descriptors: I.6.5 [Simulation and Modeling]: Model Development, Measurement Additional Key Words and Phrases: Occupancy, HVAC, Ventilation, Energy savings, Demand Response-conditioning (HVAC) systems [EIA 2010]. Studies suggest that 15% to 25% of HVAC energy can be saved by setting

Cerpa, Alberto E.

254

Commissioning and Performance Diagnostics for HVAC Control Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Commissioning and Performance Diagnostics for HVAC Control Systems Commissioning and Performance Diagnostics for HVAC Control Systems Speaker(s): Ashish Singhal Date: December 20, 2006 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Philip Haves The presentation will focus on practical aspects of commissioning control loops in commercial HVAC systems and evaluating their routine performance. Simple and theoretically sound methods for diagnosing control performance will be presented that detect serious performance issues associated with control loops in modern buildings. The discussion will center on a new control loop commissioning tool that helps field personnel to quickly test, tune and troubleshoot control loops. In addition to the active tests for commissioning control loops, a suite of diagnostic algorithms are used in a

255

Optimized HVAC Management Service to Enhance Demand Response  

NLE Websites -- All DOE Office Websites (Extended Search)

Optimized HVAC Management Service to Enhance Demand Response Optimized HVAC Management Service to Enhance Demand Response Speaker(s): John Steinberg Date: August 18, 2011 - 12:00pm Location: 90-4133 Seminar Host/Point of Contact: Janie Page Many utilities are investing vast sums deploying smart meters to customers, some of whom remain stubbornly opposed to those deployments, in large part because they remain unmoved by the claimed benefits. EcoFactor has developed a thermostat management service that delivers (and quantifies) significant energy savings for consumers and a number of additional benefits to other players in the energy value chain. It does so without relying on consumers to modify behavior, study energy information displays, or even pay attention to their energy use. EcoFactor also significantly boosts DR yield while it increases occupant comfort. It can identify HVAC

256

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives Ameren Illinois (Electric) - Custom, HVAC, and Motor Business Efficiency Incentives < Back Eligibility Commercial Industrial Multi-Family Residential Nonprofit Savings Category Other Heating & Cooling Commercial Heating & Cooling Cooling Home Weatherization Construction Commercial Weatherization Design & Remodeling Manufacturing Sealing Your Home Ventilation Heat Pumps Heating Appliances & Electronics Commercial Lighting Lighting Water Heating Maximum Rebate $600,000/year/facility. Incentives $1-$200,000: paid at 100% Incentives $200,000-$600,000: paid at 50% Custom: 50% of incremental cost Retro-Commissioning: $200,000/year/facility; $100,000/project Leak Survey: $10,000

257

Evaluating fugacity models for trace components in landfill gas  

Science Journals Connector (OSTI)

A fugacity approach was evaluated to reconcile loadings of vinyl chloride (chloroethene), benzene, 1,3-butadiene and trichloroethylene in waste with concentrations observed in landfill gas monitoring studies. An evaluative environment derived from fictitious but realistic properties such as volume, composition, and temperature, constructed with data from the Brogborough landfill (UK) test cells was used to test a fugacity approach to generating the source term for use in landfill gas risk assessment models (e.g. GasSim). SOILVE, a dynamic Level II model adapted here for landfills, showed greatest utility for benzene and 1,3-butadiene, modelled under anaerobic conditions over a 10 year simulation. Modelled concentrations of these components (95?300 ?g m?3; 43 ?g m?3) fell within measured ranges observed in gas from landfills (24?300–180?000 ?g m?3; 20–70 ?g m?3). This study highlights the need (i) for representative and time-referenced biotransformation data; (ii) to evaluate the partitioning characteristics of organic matter within waste systems and (iii) for a better understanding of the role that gas extraction rate (flux) plays in producing trace component concentrations in landfill gas.

Sophie Shafi; Andrew Sweetman; Rupert L. Hough; Richard Smith; Alan Rosevear; Simon J.T. Pollard

2006-01-01T23:59:59.000Z

258

Estimating Predictive Variance for Statistical Gas Distribution Modelling  

SciTech Connect

Recent publications in statistical gas distribution modelling have proposed algorithms that model mean and variance of a distribution. This paper argues that estimating the predictive concentration variance entails not only a gradual improvement but is rather a significant step to advance the field. This is, first, since the models much better fit the particular structure of gas distributions, which exhibit strong fluctuations with considerable spatial variations as a result of the intermittent character of gas dispersal. Second, because estimating the predictive variance allows to evaluate the model quality in terms of the data likelihood. This offers a solution to the problem of ground truth evaluation, which has always been a critical issue for gas distribution modelling. It also enables solid comparisons of different modelling approaches, and provides the means to learn meta parameters of the model, to determine when the model should be updated or re-initialised, or to suggest new measurement locations based on the current model. We also point out directions of related ongoing or potential future research work.

Lilienthal, Achim J.; Asadi, Sahar; Reggente, Matteo [AASS Research Center, Oerebro University (Sweden)

2009-05-23T23:59:59.000Z

259

Generalized Chaplygin gas model: Cosmological consequences and statefinder diagnosis  

E-Print Network (OSTI)

The generalized Chaplygin gas (GCG) model in spatially flat universe is investigated. The cosmological consequences led by GCG model including the evolution of EoS parameter, deceleration parameter and dimensionless Hubble parameter are calculated. We show that the GCG model behaves as a general quintessence model. The GCG model can also represent the pressureless CDM model at the early time and cosmological constant model at the late time. The dependency of transition from decelerated expansion to accelerated expansion on the parameters of model is investigated. The statefinder parameters $r$ and $s$ in this model are derived and the evolutionary trajectories in $s-r$ plane are plotted. Finally, based on current observational data, we plot the evolutionary trajectories in $s-r$ and $q-r$ planes for best fit values of the parameters of GCG model. It has been shown that although, there are similarities between GCG model and other forms of chaplygin gas in statefinder plane, but the distance of this model from the $\\Lambda$CDM fixed point in $s-r$ diagram is shorter compare with standard chaplygin gas model.

M. Malekjani; A. Khodam-Mohammadi; N. Nazari-Pooya

2011-03-09T23:59:59.000Z

260

Radon entry rate analyses using in situ tracer gas method application  

Science Journals Connector (OSTI)

......indoor environment, standard methods of radon diagnosis...ventilation (specific modes of HVAC systems operation...for new houses given in standards. Table-5. Results...efforts to comply with the standard requirements on new buildings...services in buildings like HVAC systems, water and gas......

A. Fro?ka; K. Jílek

2014-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Buildings, Energy, Greenhouse Gas, Industrial and Policy Modeling and  

NLE Websites -- All DOE Office Websites (Extended Search)

Buildings, Energy, Greenhouse Gas, Industrial and Policy Modeling and Buildings, Energy, Greenhouse Gas, Industrial and Policy Modeling and Simulation Tools Available from Energy Analysis and Environmental Impacts Department Tools header image January 2014 Tools and models to find the best way to save energy and reduce greenhouse gas emissions in cities and industries, to follow the transport of pollutants through the environment, and to calculate the cost of power interruptions are among those available on a new Lawrence Berkeley National Laboratory (Berkeley Lab) web site. The site brings together models and simulation tools developed by the Energy Analysis and Environmental Impacts (EAEI) Department of the Lab's Environmental Energy Technologies Division. "Our hope is that the site will facilitate greater technical awareness of

262

Introducing Chaos in Economic Gas-like Models  

E-Print Network (OSTI)

This paper considers ideal gas-like models of trading markets, where each agent is identified as a gas molecule that interacts with others trading in elastic or money-conservative collisions. Traditionally, these models introduce different rules of random selection and exchange between pair agents. Unlike these traditional models, this work introduces a chaotic procedure able of breaking the pairing symmetry of agents (i,j)->(j,i). Its results show that, the asymptotic money distributions of a market under chaotic evolution can exhibit a transition from Gibbs to Pareto distributions, as the pairing symmetry is progressively broken.

C. Pellicer-Lostao; R. Lopez-Ruiz

2009-04-02T23:59:59.000Z

263

Model methodology and data description of the Production of Onshore Lower 48 Oil and Gas model  

SciTech Connect

This report documents the methodology and data used in the Production of Onshore Lower 48 Oil and Gas (PROLOG) model. The model forecasts annual oil and natural gas production on a regional basis. Natural gas is modeled by gas category, generally conforming to categories defined by the Natural Gas Policy Act (NGPA) of 1978, as well as a category representing gas priced by way of a spot market (referred to as ''spot'' gas). A linear program is used to select developmental drilling activities for conventional oil and gas and exploratory drilling activities for deep gas on the basis of their economic merit, subject to constraints on available rotary rigs and constraints based on historical drilling patterns. Using exogenously specified price paths for oil and gas, net present values are computed for fixed amounts of drilling activity for oil and gas development and deep gas exploration in each of six onshore regions. Through maximizing total net present value, the linear program provides forecasts of drilling activities, reserve additions, and production. Oil and shallow gas exploratory drilling activities are forecast on the basis of econometrically derived equations, which are dependent on specified price paths for the two fuels. 10 refs., 3 figs., 10 tabs.

Not Available

1988-09-01T23:59:59.000Z

264

Quantum thermodynamic fluctuations of a chaotic Fermi-gas model  

E-Print Network (OSTI)

We investigate the thermodynamics of a Fermi gas whose single-particle energy levels are given by the complex zeros of the Riemann zeta function. This is a model for a gas, and in particular for an atomic nucleus, with an underlying fully chaotic classical dynamics. The probability distributions of the quantum fluctuations of the grand potential and entropy of the gas are computed as a function of temperature and compared, with good agreement, with general predictions obtained from random matrix theory and periodic orbit theory (based on prime numbers). In each case the universal and non--universal regimes are identified.

P. Leboeuf; A. G. Monastra

2003-02-28T23:59:59.000Z

265

COMPUTATIONAL MODELING OF MUONS PASSING THROUGH GAS PRESSURED RF CAVITIES  

E-Print Network (OSTI)

of muons passing through matter. PHYSICAL MODEL We start our study with a classical scattering of muonsCOMPUTATIONAL MODELING OF MUONS PASSING THROUGH GAS PRESSURED RF CAVITIES A. Samolov, A. Godunov, and to validate a technical design of these new accelerating facilities, accu- rate and comprehensive simulations

Godunov, Alexander L.

266

Dense gas dispersion modeling for aqueous releases  

E-Print Network (OSTI)

, the HGSYSTEM contains HEGADAS. Both AEROPLUME AND HEGADAS will be interfaced with the proposed thermodynamic model. Appendix C shows the code written in FORTRAN of the subroutines that are interfaced with HGSYSTEM modules. Also the two HGSYSTEM modules..., the HGSYSTEM contains HEGADAS. Both AEROPLUME AND HEGADAS will be interfaced with the proposed thermodynamic model. Appendix C shows the code written in FORTRAN of the subroutines that are interfaced with HGSYSTEM modules. Also the two HGSYSTEM modules...

Lara, Armando

2012-06-07T23:59:59.000Z

267

Renormalization group maps for Ising models in lattice gas variables  

E-Print Network (OSTI)

Real space renormalization group maps, e.g., the majority rule transformation, map Ising type models to Ising type models on a coarser lattice. We show that each coefficient of the renormalized Hamiltonian in the lattice gas variables depends on only a finite number of values of the renormalized Hamiltonian. We introduce a method which computes the values of the renormalized Hamiltonian with high accuracy and so computes the coefficients in the lattice gas variables with high accuracy. For the critical nearest neighbor Ising model on the square lattice with the majority rule transformation, we compute over 1,000 different coefficients in the lattice gas variable representation of the renormalized Hamiltonian and study the decay of these coefficients. We find that they decay exponentially in some sense but with a slow decay rate. We also show that the coefficients in the spin variables are sensitive to the truncation method used to compute them.

Tom Kennedy

2009-05-15T23:59:59.000Z

268

An Equilibrium-Based Model of Gas Reaction and Detonation  

SciTech Connect

During gaseous diffusion plant operations, conditions leading to the formation of flammable gas mixtures may occasionally arise. Currently, these could consist of the evaporative coolant CFC-114 and fluorinating agents such as F2 and ClF3. Replacement of CFC-114 with a non-ozone-depleting substitute is planned. Consequently, in the future, the substitute coolant must also be considered as a potential fuel in flammable gas mixtures. Two questions of practical interest arise: (1) can a particular mixture sustain and propagate a flame if ignited, and (2) what is the maximum pressure that can be generated by the burning (and possibly exploding) gas mixture, should it ignite? Experimental data on these systems, particularly for the newer coolant candidates, are limited. To assist in answering these questions, a mathematical model was developed to serve as a tool for predicting the potential detonation pressures and for estimating the composition limits of flammability for these systems based on empirical correlations between gas mixture thermodynamics and flammability for known systems. The present model uses the thermodynamic equilibrium to determine the reaction endpoint of a reactive gas mixture and uses detonation theory to estimate an upper bound to the pressure that could be generated upon ignition. The model described and documented in this report is an extended version of related models developed in 1992 and 1999.

Trowbridge, L.D.

2000-04-01T23:59:59.000Z

269

Energy efficient control of HVAC systems with ice cold thermal energy storage  

Science Journals Connector (OSTI)

Abstract In heating, ventilation and air conditioning (HVAC) systems of medium/high cooling capacity, energy demands can be matched with the help of thermal energy storage (TES) systems. If properly designed, TES systems can reduce energy costs and consumption, equipment size and pollutant emissions. In order to design efficient control strategies for TES systems, we present a model-based approach with the aim of increasing the performance of HVAC systems with ice cold thermal energy storage (CTES). A simulation environment based on Matlab/Simulink® is developed, where thermal behaviour of the plant is analysed by a lumped formulation of the conservation equations. In particular, the ice CTES is modelled as a hybrid system, where the water phase transitions (solid–melting–liquid and liquid–freezing–solid) are described by combining continuous and discrete dynamics, thus considering both latent and sensible heat. Standard control strategies are compared with a non-linear model predictive control (NLMPC) approach. In the simulation examples model predictive control proves to be the best control solution for the efficient management of ice CTES systems.

Alessandro Beghi; Luca Cecchinato; Mirco Rampazzo; Francesco Simmini

2014-01-01T23:59:59.000Z

270

Use of EMCS Recorded Data to Identify Potential Savings Due to Improved HVAC Operations & Maintenance (O&M)  

E-Print Network (OSTI)

Use of EMCS Recorded Data to Identify Potential Savings Due to Improved HVAC Operations & Maintenance(O&M) Mingsheng Liu, Yeqiao Zhu, and David Claridge Energy Systems Laboratory Texas A&M University ABSTRACT In most chiller and boiler central... and cooling energy consumption using an appropriate model [Liu 1995, Liu and Claridge 19951 with the bin weather data for each building. Step 5: Calculate the campus consumption as the sum of consumption of all buildings. Step 6: Compare the simulated...

Liu, M.; Zhu, Y.; Claridge, D. E.

1996-01-01T23:59:59.000Z

271

Optimizing HVAC Control to Improve Building Comfort and Energy Performance  

E-Print Network (OSTI)

This paper demonstrates the benefits of optimal control in well-designed and operated buildings using a case study. The case study building was built in 2001. The HVAC and control systems have been installed with state-of-the-art equipment which...

Song, L.; Joo, I.; Dong, D.; Liu, M.; Wang, J.; Hansen, K.; Quiroz, L.; Swiatek, A.

2003-01-01T23:59:59.000Z

272

Air filtration: Choosing the right filter class for HVAC systems  

Science Journals Connector (OSTI)

As anyone who works with air filtration knows, getting the best from a system is about more than choosing efficient media and correct installation. Thomas Carlson of Vokes Air explains the importance of using and selecting the right filter class for a typical HVAC system.

Thomas Carlson

2008-01-01T23:59:59.000Z

273

Performance Validation and Energy Analysis of HVAC Systems using Simulation  

E-Print Network (OSTI)

that energy savings of between 15% and 40% could be made in commercial buildings by closer monitoring and supervision of energy-usage and related data. An earlier study by Kao and Pierce (1983) showed that sensor1 Performance Validation and Energy Analysis of HVAC Systems using Simulation Tim Salsbury and Rick

Diamond, Richard

274

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System  

NLE Websites -- All DOE Office Websites (Extended Search)

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage Title Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage Publication Type Conference Proceedings Refereed Designation Refereed LBNL Report Number LBNL-6127E Year of Publication 2013 Authors Mammoli, Andrea, Michael Stadler, Nicholas DeForest, Hans Barsun, Richard Burnett, and Chris Marnay Conference Name 3rd International Conference on Microgeneration and Related Technologies Date Published 04/2013 Conference Location Naples, Italy Keywords absorption cooling, mixed integer programming, optimisation, software-as-a-service, thermal storage Abstract The UNM Mechanical Engineering HVAC system incorporates cooling assisted by a 232 m2 solar thermal array providing heat to a 70 kWthermal absorption chiller. A 30 m3 heat storage tank solar decouples heat production and absorption cooling. Additionally, 350 m3 of chilled water storage shifts the cooling electrical load of this high desert location off-peak. While this system already provides substantial energy and cost savings compared to similar conventional buildings, there are still opportunities for improvement. Absorption cooling (augmented by an electrically powered central cooling loop) suffers from parasitic electric loads from a cooling tower pump, a cooling tower fan, and hot and chilled water circulation pumps. Moreover, depending on seasonal, weather, occupancy, and cost conditions, the cold storage tanks may only need partial charging to meet the next day's net building load, and losses need to be considered. Optimally operating this complex thermal-electrical system poses a challenging mathematical problem. A model of the system was built on LBNL's Distributed Resources Customer Adoption Model (DER-CAM) platform. A direct interface between the building energy control system, and DER-CAM hosted on LBNL's server was developed. This interface delivers daily scheduling based on weather forecasts, tariffs, etc., to the building controller. It is found that energy cost savings can be proportionally substantial (almost 30%) - although in this case the payback period for system implementation is long, due to the very low energy consumption of the building. Also, it is found that accurate weather forecasting is a key ingredient of the optimization, although local biases can be corrected for in the optimization.

275

Modeling well performance in compartmentalized gas reservoirs  

E-Print Network (OSTI)

index in estimating reservoir performance. • The optimization routine is done with VBA using Excel solver. Model Assumptions • The reservoir is in stabilized flow under pseudo-steady state conditions at constant pressure with no aquifer influx... is matched with a type curve to predict field performance. Fetkovich Decline Type Curves 11 is based on analytical solutions to flow equations for production at constant BHP and include both transient and boundary dominated flow periods. These log...

Yusuf, Nurudeen

2008-10-10T23:59:59.000Z

276

Modeling well performance in compartmentalized gas reservoirs  

E-Print Network (OSTI)

index in estimating reservoir performance. ? The optimization routine is done with VBA using Excel solver. Model Assumptions ? The reservoir is in stabilized flow under pseudo-steady state conditions at constant pressure with no aquifer influx... is matched with a type curve to predict field performance. Fetkovich Decline Type Curves 11 is based on analytical solutions to flow equations for production at constant BHP and include both transient and boundary dominated flow periods. These log...

Yusuf, Nurudeen

2009-05-15T23:59:59.000Z

277

Survival of bioaerosols in HVAC system photocatalytic filters  

Science Journals Connector (OSTI)

Abstract The survival of an experimental bioaerosol in photocatalytic and non-photocatalytic filters was investigated under UV-A or UV-C radiation exposure. To ensure the generation of reproducible bioaerosols in real operating conditions of Heating, Ventilation and Air Conditioning (HVAC) systems and their homogeneous coating on filters, a reactor with an optimal geometry was developed. The bacterial aerosol was generated from standardised bacterial suspensions and the Gram-negative bacterial model Escherichia coli was used as the experimental organism. The bioaerosol was characterised in terms of particle size distribution, reproducibility and stability over time. The coating of aerosolised cells on the filters was then studied. The total number of aerosolised E. coli cells was different from the amount of cultivable bacterial cells extracted from filters, probably resulting from the stress of the aerosolisation process. Damages to the outer membrane of E. coli cells were clearly observed through SEM and epifluorescent microscopy analysis. The influence of important physical parameters in the reactor-aerosolisation duration, frontal velocity and relative humidity- on the amount of aerosolised cells coated on filters were also investigated. Finally, the effects of UV-A or UV-C radiation were assessed on aerosolised microorganisms coated on HEPA photocatalytic filters and on photocatalytic or non-photocatalytic filters containing activated charcoal. The HEPA photocatalytic filters demonstrated a better disinfection efficiency with full damages of the aerosolised bacterial cells, probably resulting from an optimal contact between TiO2 coating and the microorganisms. In contrast, the use of filters with activated charcoal resulted in the apparition of an inactivation threshold that could be attributed to the penetration of aerosolised cells within the activated charcoal layer and the absence of contact with the photocatalyst. However, UV-C photocatalysis was able to inactivate faster and, at the same time, mineralise biological pollutants than UV-A.

S. Pigeot-Remy; J.C. Lazzaroni; F. Simonet; P. Petinga; C. Vallet; P. Petit; P.J. Vialle; C. Guillard

2014-01-01T23:59:59.000Z

278

Structure and anomalous solubility for hard spheres in an associating lattice gas model  

E-Print Network (OSTI)

Structure and anomalous solubility for hard spheres in an associating lattice gas model Marcia M spheres in an associating lattice gas model Marcia M. Szortyka,1,a) Mauricio Girardi,2,b) Vera B-sphere gas in a solvent modeled as an associating lattice gas. The solution phase diagram for solute at 5

Barbosa, Marcia C. B.

279

Modeling acid-gas generation from boiling chloride brines  

SciTech Connect

This study investigates the generation of HCl and other acid gases from boiling calcium chloride dominated waters at atmospheric pressure, primarily using numerical modeling. The main focus of this investigation relates to the long-term geologic disposal of nuclear waste at Yucca Mountain, Nevada, where pore waters around waste-emplacement tunnels are expected to undergo boiling and evaporative concentration as a result of the heat released by spent nuclear fuel. Processes that are modeled include boiling of highly concentrated solutions, gas transport, and gas condensation accompanied by the dissociation of acid gases, causing low-pH condensate. Simple calculations are first carried out to evaluate condensate pH as a function of HCl gas fugacity and condensed water fraction for a vapor equilibrated with saturated calcium chloride brine at 50-150 C and 1 bar. The distillation of a calcium-chloride-dominated brine is then simulated with a reactive transport model using a brine composition representative of partially evaporated calcium-rich pore waters at Yucca Mountain. Results show a significant increase in boiling temperature from evaporative concentration, as well as low pH in condensates, particularly for dynamic systems where partial condensation takes place, which result in enrichment of HCl in condensates. These results are in qualitative agreement with experimental data from other studies. The combination of reactive transport with multicomponent brine chemistry to study evaporation, boiling, and the potential for acid gas generation at the proposed Yucca Mountain repository is seen as an improvement relative to previously applied simpler batch evaporation models. This approach allows the evaluation of thermal, hydrological, and chemical (THC) processes in a coupled manner, and modeling of settings much more relevant to actual field conditions than the distillation experiment considered. The actual and modeled distillation experiments do not represent expected conditions in an emplacement drift, but nevertheless illustrate the potential for acid-gas generation at moderate temperatures (<150 C).

Zhang, Guoxiang; Spycher, Nicolas; Sonnenthal, Eric; Steefel, Carl

2009-11-16T23:59:59.000Z

280

Simulation of single acting natural gas Reciprocating Expansion Engine based on ideal gas model  

Science Journals Connector (OSTI)

Abstract The potential energy of high pressure gas destroyed in natural gas pressure reduction stations during pressure reduction when it passes through throttling valves. One way to recover this energy is to use a Reciprocating Expansion Engine coupled with a generator. The expansion engine is able to produce electricity as pressure decreases by recovering the potential energy. Although the expansion engine has been utilized in pressure reduction points for some time but it has not been analyzed for performance enhancement yet. In this work an advanced numerical simulation has been presented for the thermodynamic modeling of Natural Gas Single Acting Reciprocating Expansion Engine under various working conditions for high pressure ranges. The simulation has been carried out to understand the effects of various parameters and to improve performance of the engine. A range of geometric parameters such as suction diameter, piston diameter, crank radius, connecting rod length, speed were covered in this research. Because of the physical and numerical difficulties of the problem, the natural gas is assumed as an ideal gas.

Mahmood Farzaneh Gord; Mohsen Jannatabadi

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

MODELLING OF GAS PLOWS IN THE GOAF OF RETREATING FACES  

E-Print Network (OSTI)

(Lorraine Basin Collieries, 1990) and the Back Retum System used in Great Britain (British Coal, 1993 of the inaccessibility of this area. Thus, the modelling of gas flows (air, methane and nitrogen) is an investigation method which is fairly well adapted to the Situation. This approach is made possible by the development

Paris-Sud XI, Université de

282

FRW Cosmological model with Modified Chaplygin Gas and Dynamical System  

E-Print Network (OSTI)

The Friedmann-Robertson-Walker(FRW) model with dynamical Dark Energy(DE) in the form of modified Chaplygin gas(MCG) has been investigated. The evolution equations are reduced to an autonomous system on the two dimensional phase plane and it can be interpreted as the motion of the particle in an one dimensional potential.

Nairwita Mazumder; Ritabrata Biswas; Subenoy Chakraborty

2011-06-23T23:59:59.000Z

283

Stabilizing Hadron Resonance Gas Models against Future Discoveries  

E-Print Network (OSTI)

We examine the stability of hadron resonance gas models by extending them to take care of undiscovered resonances through the Hagedorn formula. We find that the influence of unknown resonances on thermodynamics is large but bounded. Hadron resonance gases are internally consistent up to a temperature higher than the cross over temperature in QCD; but by examining quark number susceptibilities we find that their region of applicability seems to end even below the QCD cross over. We model the decays of resonances and investigate the ratios of particle yields in heavy-ion collisions. We find that observables such as hydrodynamics and hadron yield ratios change little upon extending the model. As a result, heavy-ion collisions at RHIC and LHC are insensitive to a possible exponential rise in the hadronic density of states, thus increasing the stability of the predictions of hadron resonance gas models.

S. Chatterjee; R. M. Godbole; Sourendu Gupta

2009-06-14T23:59:59.000Z

284

Natural Gas Transmission and Distribution Model of the National Energy Modeling System. Volume 1  

SciTech Connect

The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. The NGTDM is the model within the NEMS that represents the transmission, distribution, and pricing of natural gas. The model also includes representations of the end-use demand for natural gas, the production of domestic natural gas, and the availability of natural gas traded on the international market based on information received from other NEMS models. The NGTDM determines the flow of natural gas in an aggregate, domestic pipeline network, connecting domestic and foreign supply regions with 12 demand regions. The purpose of this report is to provide a reference document for model analysts, users, and the public that defines the objectives of the model, describes its basic design, provides detail on the methodology employed, and describes the model inputs, outputs, and key assumptions. Subsequent chapters of this report provide: an overview of NGTDM; a description of the interface between the NEMS and NGTDM; an overview of the solution methodology of the NGTDM; the solution methodology for the Annual Flow Module; the solution methodology for the Distributor Tariff Module; the solution methodology for the Capacity Expansion Module; the solution methodology for the Pipeline Tariff Module; and a description of model assumptions, inputs, and outputs.

NONE

1998-01-01T23:59:59.000Z

285

Density Evolution in the New Modified Chaplygin Gas Model  

E-Print Network (OSTI)

In this paper, we have considered new modified Chaplygin gas (NMCG) model which interpolates between radiation at early stage and $\\Lambda$CDM at late stage. This model is regarded as a unification of dark energy and dark matter (with general form of matter). We have derived the density parameters from the equation of motion for the interaction between dark energy and dark matter. Also we have studied the evolution of the various components of density parameters.

Surajit Chattopadhyay; Ujjal Debnath

2008-05-01T23:59:59.000Z

286

Radiant heating and cooling, displacement ventilation with heat recovery and storm water cooling: An environmentally responsible HVAC system  

SciTech Connect

This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.

Carpenter, S.C.; Kokko, J.P. [Enermodal Engineering Ltd., Kitchener, Ontario (Canada)

1998-12-31T23:59:59.000Z

287

Baltimore Gas and Electric Company (Gas) - Residential Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

(Gas) - Residential Energy (Gas) - Residential Energy Efficiency Rebate Program Baltimore Gas and Electric Company (Gas) - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Home Weatherization Commercial Weatherization Sealing Your Home Ventilation Manufacturing Heating & Cooling Commercial Heating & Cooling Heating Program Info State Maryland Program Type Utility Rebate Program Rebate Amount Gas Furnace: $300 or $400 Duct Sealing: $200 Tune-ups: $100 Installation Rebates: Contact BGE The Baltimore Gas and Electric Company (BGE) offers the Smart Energy Savers Program for residential natural gas customers to improve the energy efficiency of eligible homes. Rebates are available for furnaces, HVAC system tune-ups, and insulation measures. All equipment and installation

288

Assessment of organic compound exposures, thermal comfort parameters, and HVAC system-driven air exchange rates in public school portable classrooms in California  

E-Print Network (OSTI)

no no, y e s - only HVAC filters: sizes, when changed 68%n=2) (n=19) 100% no 95% no Current HVAC air filter was notoriginal When HVAC air filter was last changed (reported as

Shendell, Derek Garth

2010-01-01T23:59:59.000Z

289

Two Alabama Elementary Schools Get Cool with New HVAC Units | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Alabama Elementary Schools Get Cool with New HVAC Units Alabama Elementary Schools Get Cool with New HVAC Units Two Alabama Elementary Schools Get Cool with New HVAC Units October 1, 2010 - 2:05pm Addthis Winston County School District will receive 14 new HVAC units with State Energy Program funding. | File photo Winston County School District will receive 14 new HVAC units with State Energy Program funding. | File photo Lindsay Gsell What are the key facts? Two public elementary schools receive 14 new HVAC units for classrooms. School district estimates nearly 10 percent in electrical savings with new units. Nineteen Alabama public school districts using Recovery Act grants to save energy and money. Addison Elementary School and Double Springs Elementary School in northwestern Alabama were warm. Some classrooms just didn't cool fast enough. The buildings, which were

290

Combining HVAC energy conservation measures to achieve energy savings over standard requirements  

Science Journals Connector (OSTI)

Abstract This paper presents the energy savings over the minimum American Society of Heating Refrigeration and Air-Conditioning Engineers (ASHRAE) Standard 90.1-2010 requirements due to the combination of two or three HVAC energy conservation measures using EnergyPlus simulation software. Prototype commercial building models, which satisfy the requirements of ASHRAE Standard 90.1-2010 were used as base-cases. Five prototype commercial buildings, eight HVAC systems, and eight climate zones were considered. Four cases were studied for the combination: energy recovery ventilation (ERV) and demand control ventilation (DCV); ERV and Multiple-zone variable air volume (VAV) System Ventilation Optimization (VentOpt); ERV, DCV and VentOpt; and Single Zone VAV controls, and kitchen transfer air. Of the four cases studied, the integration of ERV and DCV, which was applied to primary school and standalone retail prototype buildings, provided a maximum savings of 1.93% and 8.10% respectively compared to the base-cases.

Teshome Edae Jiru

2014-01-01T23:59:59.000Z

291

Neuro-optimal operation of a variable air volume HVAC&R system  

Science Journals Connector (OSTI)

Low operational efficiency especially under partial load conditions and poor control are some reasons for high energy consumption of heating, ventilation, air conditioning and refrigeration (HVAC&R) systems. To improve energy efficiency, HVAC&R systems should be efficiently operated to maintain a desired indoor environment under dynamic ambient and indoor conditions. This study proposes a neural network based optimal supervisory operation strategy to find the optimal set points for chilled water supply temperature, discharge air temperature and VAV system fan static pressure such that the indoor environment is maintained with the least chiller and fan energy consumption. To achieve this objective, a dynamic system model is developed first to simulate the system behavior under different control schemes and operating conditions. A multi-layer feed forward neural network is constructed and trained in unsupervised mode to minimize the cost function which is comprised of overall energy cost and penalty cost when one or more constraints are violated. After training, the network is implemented as a supervisory controller to compute the optimal settings for the system. Simulation results show that compared to the conventional night reset operation scheme, the optimal operation scheme saves around 10% energy under full load condition and 19% energy under partial load conditions.

Min Ning; M. Zaheeruddin

2010-01-01T23:59:59.000Z

292

Numerical Early Warning Model Research of Landfill Gas Permeation and Diffusion Considering Flow-Temperature Coupling  

Science Journals Connector (OSTI)

Based on seepage mechanics in porous medium gas and heat transfer theory, numerical early warning model is established, which is on quantitative description of migration and release of landfill gas and penetration and diffusion of energy, and dynamic ... Keywords: component, landfill gas, flow-temperature coupling, gas pressure and temperature distribution, numerical early warning model

Xue Qiang; Feng Xia-ting; Ma Shi-jin; Zhou Xiao-jun

2009-10-01T23:59:59.000Z

293

Mathematical model and simulation of gas ow through a porous medium in high breaking capacity  

E-Print Network (OSTI)

Mathematical model and simulation of gas #29;ow through a porous medium in high breaking capacity, France. Abstract. A one-dimensional model is introduced to describe the gas #29;ow and the heat transfer model coupled with a porous medium model taking into account the mechanical interaction gas-silica sand

Sart, Remi

294

Model equations in rarefied gas dynamics: Viscous-slip and thermal-slip coefficients  

E-Print Network (OSTI)

Model equations in rarefied gas dynamics: Viscous-slip and thermal-slip coefficients C. E. Siewert-slip and the thermal-slip coefficients in rarefied gas dynamics. More specifically, the BGK model, the S model In reviewing numerous papers devoted to model equa- tions in rarefied gas dynamics, we have found no definitive

Siewert, Charles E.

295

HVAC Radial Air Bearing Heat Exchangers Research Project | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radial Air Bearing Heat Exchangers Radial Air Bearing Heat Exchangers Research Project HVAC Radial Air Bearing Heat Exchangers Research Project The U.S. Department of Energy is currently conducting research into heating, ventilation, and air conditioning (HVAC) radial air bearing heat exchangers. Rotary air bearing heat exchanger technology simultaneously solves four long standing problems of conventional "fan-plus-finned-heat-sink" heat exchangers. Project Description This project seeks to design, fabricate, and test successive generations of prototype radial air bearing heat exchanger devices based on lessons learned and further insights into device optimization, computational fluid dynamic studies for parametric optimization and determination of scaling laws, and laboratory measurement of flow field and heat transfer

296

HVAC Optimized Heat Exchangers Research Project | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Optimized Heat Exchangers Research Optimized Heat Exchangers Research Project HVAC Optimized Heat Exchangers Research Project The U.S. Department of Energy is currently conducting research into heating, ventilation, and air conditioning (HVAC) optimized heat exchangers. The information generated in this study will demonstrate performance improvements that can be achieved through optimization of refrigerant circuitry for non-uniform inlet air distribution. The tubing circuitry on fin-tube heat exchangers used in residential space-conditioning systems is typically designed assuming uniform airflow through the finned passageways. However, the air flow in installed systems is highly non-uniform, resulting in mismatched refrigerant-air heat transfer that reduces the capacity of the heat exchanger and efficiency of

297

An Application of State-Of-The-Art HVAC and Building Systems  

E-Print Network (OSTI)

AN APPLICATION OF STATE-OF-THE-ART HVAC AND BUILDING SYSTEMS DONALD P. FIORINO, M.S., P.E. Energy Conservation Manager Texas Instruments, Inc. Defense Systems and Electronics Group Dallas, Texas ABSTRACT This case study describes... the successful application of state-of-the-art HVAC and building systems at a large commercial office and industrial facility. The facility's exterior envelope systems, HVAC systems, lighting systems, energy conservation systems, exhaust/heat recovery...

Fiorino, D. P.

298

Total Quality Commissioning for HVAC Systems to Assure High Performance Throughout the Whole Life Cycle  

E-Print Network (OSTI)

TOTAL QUALITY COMMISSIONING FOR HVAC SYSTEMS TO ASSURE HIGH PERFORMANCE THROUGHOUT THE WHOLE LIFE CYCLE By: Grahame E. Maisey, P.E., and Beverly Milestone, LEED AP Building Services Consultants INTRODUCTION Current HVAC systems... are not coming close to approaching life cycle performance expectations for energy, operation and maintenance, occupant comfort and productivity and longevity. HVAC systems in buildings claiming to be sustainable, with integrated, energy conscious design...

Maisey, G.; Milestone, B.

2005-01-01T23:59:59.000Z

299

Gas-Liquid Coexistence in the Primitive Model for Water  

E-Print Network (OSTI)

We evaluate the location of the gas-liquid coexistence line and of the associated critical point for the primitive model for water (PMW), introduced by Kolafa and Nezbeda [J. Kolafa and I. Nezbeda, Mol. Phys. 61, 161 (1987)]. Besides being a simple model for a molecular network forming liquid, the PMW is representative of patchy proteins and novel colloidal particles interacting with localized directional short-range attractions. We show that the gas-liquid phase separation is metastable, i.e. it takes place in the region of the phase diagram where the crystal phase is thermodynamically favored, as in the case of articles interacting via short-range attractive spherical potentials. Differently from spherical potentials, we do not observe crystallization close to the critical point. The region of gas-liquid instability of this patchy model is significantly reduced as compared to equivalent models of spherically interacting particles, confirming the possibility of observing kinetic arrest in an homogeneous sample driven by bonding as opposed to packing.

F. Romano; P. Tartaglia; F. Sciortino

2007-05-08T23:59:59.000Z

300

Outdoor airflow into HVAC systems: An evaluation of measurement  

NLE Websites -- All DOE Office Websites (Extended Search)

Outdoor airflow into HVAC systems: An evaluation of measurement Outdoor airflow into HVAC systems: An evaluation of measurement technologies Title Outdoor airflow into HVAC systems: An evaluation of measurement technologies Publication Type Report LBNL Report Number LBNL-53834 Year of Publication 2003 Authors Fisk, William J., David Faulkner, Douglas P. Sullivan, and William W. Delp Abstract During the last few years, new technologies have been introduced for measuring the flow rates of outdoor air (OA) into HVAC systems; however, an evaluation of these measurement technologies has not previously been published. This document describes a test system and protocols developed for controlled evaluation of these measurement technologies. The results of tests of three measurement technologies are also summarized. The test system and protocol were judged practical and very useful. The test results indicate that one measurement technology can measure OA flow rates with errors of 20% or less without a field-based calibration, as long as the OA velocities are sufficient to provide an accurately measurable pressure signal. The test results for a second measurement technology are similar; however, a difficult field-based calibration relating the OA flow rate with the pressure signal would be required to reduce errors below approximately 30%. The errors in OA flow rates measured with the third measurement technology, that uses six electronic airspeed sensors downstream of the OA inlet louver, exceeded 100%; however, these errors could be substantially reduced through a difficult field based calibration. The effects of wind on the accuracy of these measurement technologies still needs to be evaluated

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Measuring rates of outdoor airflow into HVAC systems  

SciTech Connect

During the last few years, new technologies have been introduced for measuring the flow rates of outside air into HVAC systems. This document describes one particular technology for measuring these airflows, a system and a related protocol developed to evaluate this and similar measurement technologies under conditions without wind, and the results of our evaluations. We conclude that the measurement technology evaluated can provide a reasonably accurate measurement of OA flow rate over a broad range of flow, without significantly increasing airflow resistance.

Fisk, William J.; Faulkner, David; Sullivan, Douglas P.; Delp, Woody

2002-10-01T23:59:59.000Z

302

Modeling of flowing gas diode pumped alkali lasers: dependence of the operation on the gas velocity and on the nature of the buffer gas  

Science Journals Connector (OSTI)

A simple, semi-analytical model of flowing gas diode pumped alkali lasers (DPALs) is presented. The model takes into account the rise of temperature in the lasing medium with...

Barmashenko, B D; Rosenwaks, S

2012-01-01T23:59:59.000Z

303

DOE Zero Energy Ready Home Low Load High Efficiency HVAC Webinar (Text Version)  

Energy.gov (U.S. Department of Energy (DOE))

Below is the text version of the DOE Zero Energy Ready Home webinar, Low Load High Efficiency HVAC, presented in May 2014.

304

Characterization of the HVAC performance with defroster grillers and instrument panel registers  

Science Journals Connector (OSTI)

Improving HVAC performance is of paramount importance to sustain ... was between 15 to 25 degrees with a standard distance ratio of one. During the cooling...

M. F. Kader; Y. M. Youn; Y. D. Jun…

2009-06-01T23:59:59.000Z

305

E-Print Network 3.0 - air conditioning hvac Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

systems play an important role in providing comfort in residential, commercial... of Heating, Refrigerating, and Air-Conditioning Engineers. Batterman S. and Burge H. 1995. "HVAC...

306

Numerical Investigation of Flow Induced Noise in a Simplified HVAC Duct with OpenFOAM.  

E-Print Network (OSTI)

?? Due to the growing demand for comfort, the noise generated by HVAC components should be considered by the designers. Flow induced noise is one… (more)

Wang, Cong

2013-01-01T23:59:59.000Z

307

Energy Consumption Analyses of Frequently-used HVAC System Types in High Performance Office Buildings.  

E-Print Network (OSTI)

??The high energy consumption of heating, ventilation and air-conditioning (HVAC) systems in commercial buildings is a hot topic. Office buildings, a typical building set of… (more)

Yan, Liusheng

2014-01-01T23:59:59.000Z

308

Development of a High-Efficiency Zonal Thermoelectric HVAC System for Automotive Applications  

Energy.gov (U.S. Department of Energy (DOE))

Identify a technical and business approach to accelerate the deployment of light-duty automotive TE HVAC technology, maintain occupant comfort, and improve energy efficiency.

309

Investigation of IAQ-Relevant Surface Chemistry and Emissions on HVAC Filter Materials  

SciTech Connect

Chemical reactions involving ozone of outdoor origin and indoor materials are known to be significant sources of formaldehyde and other irritant gas-phase oxidation products in the indoor environment. HVAC filters are exposed to particularly high ozone concentrations--close to outdoor levels. In this study, we investigated chemical processes taking place on the surface of filters that included fiberglass, polyester, cotton/polyester blend and synthetic (e.g., polyolefin) filter media. Ozone reactions were studied on unused filter media, and on filters that were deployed for 3 months in two different locations: at the Lawrence Berkeley National Laboratory and at the Port of Oakland. Specimens from each filter were exposed to ozone under controlled conditions in a laboratory flow tube at a constant flow of dry or humidified air (50percent relative humidity). Ozone was generated with a UV source upstream of the flow tube, and monitored using a photometric detector. Ozone breakthrough curves were recorded for each sample exposed to ~;;150 ppbv O3 for periods of ~;;1000 min, from which we estimated their uptake rate. Most experiments were performed at 1.3 L/min (corresponding to a face velocity of 0.013 m/s), except for a few tests performed at a higher airflow rate, to obtain a face velocity of 0.093 m/s, slightly closer to HVAC operation conditions. Formaldehyde and acetaldehyde, two oxidation byproducts, were collected downstream of the filter and quantified. Emissions of these volatile aldehydes were consistently higher under humidified air than under dry conditions, at which levels were near the limit of detection. Our results confirm that there are significant reactions of ozone as air containing ozone flows through HVAC filters, particularly when the filters are loaded with particles and the air is humidified. The amount of ozone reacted was not clearly related to the types of filter media, e.g., fiberglass versus synthetic. Specific fiberglass filters that were coated with an impaction oil showed significantly higher formaldehyde emissions than most other samples. Those emissions were magnified in the presence of particles (i.e., in used filters), and were observed even in the absence of ozone, which suggests that hydrolysis of filter binder or tackifier additives may be the reason for those high emissions. Mass balance calculations indicate that the emission rates of formaldehyde and acetaldehyde from the filters are generally not large enough to substantially increase indoor formaldehyde or acetaldehyde concentrations.

Destaillats, Hugo; Fisk, William J.

2010-02-01T23:59:59.000Z

310

Using Coupled Harmonic Oscillators to Model Some Greenhouse Gas Molecules  

SciTech Connect

Common greenhouse gas molecules SF{sub 6}, NO{sub 2}, CH{sub 4}, and CO{sub 2} are modeled as harmonic oscillators whose potential and kinetic energies are derived. Using the Euler-Lagrange equation, their equations of motion are derived and their phase portraits are plotted. The authors use these data to attempt to explain the lifespan of these gases in the atmosphere.

Go, Clark Kendrick C.; Maquiling, Joel T. [Department of Physics, Ateneo de Manila University, Katipunan Avenue, Quezon City (Philippines)

2010-07-28T23:59:59.000Z

311

A lattice gas model of avalanches in a granular pile  

E-Print Network (OSTI)

A granular media lattice gas (GMLG) model is used to study avalanches in a two-dimensional granular pile. We demonstrate the efficiency of the algorithm by showing that several features of the non-critical behaviour of real sandpile surfaces, such as the bounded outflow statistics or the finite-size effect of the time evolution of the pile mass, can be reproduced by this simulation approach.

Antal Karolyi; Janos Kertesz

1997-10-31T23:59:59.000Z

312

Modelica-based Modeling and Simulation to Support Research and Development in Building Energy and Control Systems  

E-Print Network (OSTI)

applied earlier for building energy modeling applicationstowards building HVAC system modeling and simulation. Forof equation-based modeling for building systems. We believe

Wetter, Michael

2010-01-01T23:59:59.000Z

313

Modeled natural and excess radiocarbon: Sensitivities to the gas exchange formulation and ocean  

E-Print Network (OSTI)

Modeled natural and excess radiocarbon: Sensitivities to the gas exchange formulation and ocean. Stocker (2008), Modeled natural and excess radiocarbon: Sensitivities to the gas exchange formulation descriptions of the air-sea gas exchange the models produce similar column inventories for excess 14 C among

Fischlin, Andreas

314

Modeling bronchial circulation with application to soluble gas exchange: description and sensitivity analysis  

E-Print Network (OSTI)

Modeling bronchial circulation with application to soluble gas exchange: description into an existing model that describes the simul- taneous exchange of heat, water, and a soluble gas in the airways and represents an avenue to understanding the ex- change process. The soluble gas used in the model simulations

George, Steven C.

315

The McCormack model for gas mixtures: Plane Couette flow R. D. M. Garcia  

E-Print Network (OSTI)

The McCormack model for gas mixtures: Plane Couette flow R. D. M. Garcia HSH Scientific Computing flow for a binary gas mixture described by the McCormack kinetic model. The solution yields, defined for binary gas mixtures in terms of the McCormack model, for semi-infinite media14 Kramers

Siewert, Charles E.

316

A Network Model for The Genesis and Migration of Gas Phase  

E-Print Network (OSTI)

1 A Network Model for The Genesis and Migration of Gas Phase Koukung Alex Chang and W. Brent, of a compositional fluid consisting of water with a dissolved hydrocarbon gas. The model captures both single phase 99% of the (effectively) stored CO2 resides in the liquid phase. Key Words: network model, gas

New York at Stoney Brook, State University of

317

Modeling gas phase nitric oxide release in lung epithelial cells Jingjing Jiang a  

E-Print Network (OSTI)

Modeling gas phase nitric oxide release in lung epithelial cells Jingjing Jiang a , Steven C- dated our model with experimental results of gas phase NO release and intracellular L enzyme on NO production. Our model predicts intracellular L-arginine and gas phase NO release over a wide

George, Steven C.

318

Markov Chain Models for GP and Variable-length GAs with Homologous Crossover  

E-Print Network (OSTI)

Markov Chain Models for GP and Variable-length GAs with Homologous Crossover Riccardo Poli School mcphee@mrs.umn.edu Abstract In this paper we present a Markov chain model for GP and variable-length GAs of the genetic material taken from the parents. We obtain this result by using the core of Vose's model for GAs

Poli, Riccardo

319

Modeling the Motion of a Hot, Turbulent Gas Nick Foster and Dimitris Metaxas  

E-Print Network (OSTI)

Modeling the Motion of a Hot, Turbulent Gas Nick Foster and Dimitris Metaxas Center for Human model gas motion due to fans and heat convection. The method combines specialized forms of the equations: Animation, Convection, Gaseous Phenomena, Gas Simulations, Physics-Based Modeling, Steam, Smoke, Turbulent

Frey, Pascal

320

Cerebral autoregulation and gas exchange studied using a human cardiopulmonary model  

E-Print Network (OSTI)

Cerebral autoregulation and gas exchange studied using a human cardiopulmonary model K. Lu,1 J. W autoregulation, brain gas ex- change, and their interaction by means of a mathematical model. We have previously of intracranial dynamics. However, their models did not include gas transport in brain tissue and thus can

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Modeling of Gas Extraction from Closed Coal Mines C. Lagny & Z. Pokryszka  

E-Print Network (OSTI)

Modeling of Gas Extraction from Closed Coal Mines C. Lagny & Z. Pokryszka Direction des risques du gas flow rate. Validations were made for several years. This model is able to evaluate firedamp of indus- trial gas drainage from the surface. In this aim, a specific mathematical model has been

Paris-Sud XI, Université de

322

Title of Dissertation: MODELING LASER PULSE EVOLUTION IN IONIZING GAS AND PLASMA WITH  

E-Print Network (OSTI)

ABSTRACT Title of Dissertation: MODELING LASER PULSE EVOLUTION IN IONIZING GAS AND PLASMA to model propagation in tenuous gas and plasma and we provide relevant information about the validation energy distribution. #12;MODELING LASER PULSE EVOLUTION IN IONIZING GAS AND PLASMA WITH APPILCATION

Anlage, Steven

323

Parameter identification in large-scale models for oil and gas production  

E-Print Network (OSTI)

Parameter identification in large-scale models for oil and gas production Jorn F.M. Van Doren: Models used for model-based (long-term) operations as monitoring, control and optimization of oil and gas information to the identification problem. These options are illustrated with examples taken from oil and gas

Van den Hof, Paul

324

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage  

E-Print Network (OSTI)

solar energy available would result in overcharging of the hot storage.of a solar-assisted HVAC system with thermal storage. Energystorage and solar- assisted HVAC for the purpose of optimizing its energy

Mammoli, Andrea

2014-01-01T23:59:59.000Z

325

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage  

E-Print Network (OSTI)

of a solar-thermal- assisted hvac system. Energy andsolar thermal collectors using flat reflective surfaces. Solar Energy,of a solar-assisted HVAC system with thermal storage. Energy

Mammoli, Andrea

2014-01-01T23:59:59.000Z

326

Procedures to identify Energy Conservation Opportunities applied to HVAC system: example of VSD of chilled water pumps  

E-Print Network (OSTI)

Procedures to identify Energy Conservation Opportunities applied to HVAC system: example of VSD of HVAC equipment using variable speed drive (VSD) is an Energy Conservation Opportunity (ECO) which can

Paris-Sud XI, Université de

327

Proceedings of Healthy Buildings 2009 Paper 535 HVAC filters as "passive" samplers: fate analysis of indoor particles  

E-Print Network (OSTI)

Proceedings of Healthy Buildings 2009 Paper 535 HVAC filters as "passive" samplers: fate analysis the effectiveness of using HVAC filters as an indoor sampling technique. #12;Proceedings of Healthy Buildings 2009

Siegel, Jeffrey

328

The nonequilibrium Ehrenfest gas: a chaotic model with flat obstacles?  

E-Print Network (OSTI)

It is known that the non-equilibrium version of the Lorentz gas (a billiard with dispersing obstacles, electric field and Gaussian thermostat) is hyperbolic if the field is small. Differently the hyperbolicity of the non-equilibrium Ehrenfest gas constitutes an open problem, since its obstacles are rhombi and the techniques so far developed rely on the dispersing nature of the obstacles. We have developed analytical and numerical investigations which support the idea that this model of transport of matter has both chaotic (positive Lyapunov exponent) and non-chaotic steady states with a quite peculiar sensitive dependence on the field and on the geometry, not observed before. The associated transport behaviour is correspondingly highly irregular, with features whose understanding is of both theoretical and technological interest.

Carlo Bianca; Lamberto Rondoni

2008-11-25T23:59:59.000Z

329

Proposal for the Award of a Contract for Maintenance, Operation and Minor Installation Work for CERN Cooling and HVAC Systems  

E-Print Network (OSTI)

Proposal for the Award of a Contract for Maintenance, Operation and Minor Installation Work for CERN Cooling and HVAC Systems

1996-01-01T23:59:59.000Z

330

Economic Nonlinear Model Predictive Control for the Optimization of Gas Pipeline Networks  

E-Print Network (OSTI)

Economic Nonlinear Model Predictive Control for the Optimization of Gas Pipeline Networks EWO University Oct 12, 2011 Ajit Gopalakrishnan (CMU) Economic NMPC for gas pipeline optimization Oct 12, 2011 1 Gopalakrishnan (CMU) Economic NMPC for gas pipeline optimization Oct 12, 2011 4 / 24 #12;Natural Gas Industry

Grossmann, Ignacio E.

331

U.S. GEOLOGICAL SURVEY ASSESSMENT MODEL FOR UNDISCOVERED CONVENTIONAL OIL, GAS, AND NGL  

E-Print Network (OSTI)

AM-i Chapter AM U.S. GEOLOGICAL SURVEY ASSESSMENT MODEL FOR UNDISCOVERED CONVENTIONAL OIL, GAS Survey (USGS) periodically conducts assessments of the oil, gas, and natural-gas liquids (NGL) resources by the USGS in1998 for undiscovered oil, gas, and NGL resources that reside in conventional accumulations

Laughlin, Robert B.

332

Model 923-B Mouse Gas Anesthesia Head Holder Adaptor Adjustment Features  

E-Print Network (OSTI)

Model 923-B Mouse Gas Anesthesia Head Holder Adaptor Adjustment Features Dorsal/Ventral dial.352.3139 Toll Free: 1.877.352.3275 ^^ci&ion Q)e&i^n^^^r ^esea/H^/i Model 923-B Mouse Gas Anesthesia Head Holder 923B-1/07 #12;MODEL 923-B MOUSE GAS ANESTHESIA HEAD HOLDER The KOPF Mouse Gas Anesthesia Head Holder

Kleinfeld, David

333

1736 IEEE TRANSACTIONS ON COMMUNICATIONS, VOL. 51, NO. 10, OCTOBER 2003 Impulse Response of the HVAC Duct as a  

E-Print Network (OSTI)

of the HVAC Duct as a Communication Channel Pavel V. Nikitin, Member, IEEE, Daniel D. Stancil, Senior Member (HVAC) ducts in buildings behave as multimode waveguides when excited at radio frequencies and thus, can of a usual indoor propagation channel. In this paper, we describe physical mechanisms which affect the HVAC

Hochberg, Michael

334

7/11/00-draft copy: do not quote 1 of 30 New Technologies for Residential HVAC Ducts  

E-Print Network (OSTI)

7/11/00-draft copy: do not quote 1 of 30 New Technologies for Residential HVAC Ducts Burke Treidler is not evaluated and HVAC contractors overcome duct system shortcomings by installing oversized equipment Technologies for Residential HVAC Ducts fittings with some use of ductboard. Fittings that snap together were

335

Feasibility of Retrofitting Centralized HVAC Systems for Room-Level Zoning Tamim Sookoor, Brian Holben, Kamin Whitehouse  

E-Print Network (OSTI)

Feasibility of Retrofitting Centralized HVAC Systems for Room-Level Zoning Tamim Sookoor, Brian {sookoor,bnh4k,whitehouse}@cs.virginia.edu Abstract--Heating, ventilation, and cooling (HVAC) accounts's largest energy consumers. Many attempts have been made to optimize the control of HVAC systems

Whitehouse, Kamin

336

IEEE TRANSACTIONS ON COMMUNICATIONS, VOL. 53, NO. 2, FEBRUARY 2005 335 On the Capacity Limits of HVAC Duct Channel for  

E-Print Network (OSTI)

of HVAC Duct Channel for High-Speed Internet Access Ariton E. Xhafa, Member, IEEE, Ozan K. Tonguz, Member and experimental channel-capacity estimates of heating, ventilation, and air condi- tioning (HVAC) ducts based suppressed. Our experimental results also show that even in the case of more complex HVAC duct networks (i

Stancil, Daniel D.

337

Co-design of control algorithm and embedded platform for building HVAC systems  

Science Journals Connector (OSTI)

The design of heating, ventilation and air conditioning (HVAC) systems is crucial for reducing energy consumption in buildings. As complex cyber-physical systems, HVAC systems involve three closely-related subsystems -- the control algorithm, the physical ... Keywords: building energy efficiency, co-design, platform-based design

Mehdi Maasoumy; Qi Zhu; Cheng Li; Forrest Meggers; Alberto Sangiovanni-Vincentelli

2013-04-01T23:59:59.000Z

338

Fouling of HVAC Fin and Tube Heat Exchangers Jeffrey Siegel and Van P. Carey  

E-Print Network (OSTI)

Fouling of heat exchangers used in heating, ventilating, and air conditioning (HVAC) systems is important contributor to overall energy use and peak electric demand. Furthermore, the location of heat exchangers in HVAC systems means that if bioaerosols containing bacteria, fungi, and viruses deposit on heat

339

Application of Multizone HVAC Control Using Wireless Sensor Networks and Actuating Vent Registers  

E-Print Network (OSTI)

Most residential heating, ventilating, and air conditioning (HVAC) systems are designed to treat the home as a single zone. Single zone control consists of one thermostat, in a central area of the house that controls the HVAC operation. In a single...

Watts, W.; Koplow, M.; Redfern, A.; Wright, P.

2007-01-01T23:59:59.000Z

340

Energy Savings with Energy-Efficient HVAC Systems in Commercial Buildings of Hong Kong  

E-Print Network (OSTI)

of the electricity in Hong Kong is consumed by commercial buildings, and heating, ventilation and air-conditioning (HVAC) is the largest end-user in such buildings, improving the efficiency of HVAC systems in commercial buildings, is the key measure to take in Hong...

Yang, J.; Chan, K.; Wu, X.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Reliability and Functional Availability of HVAC Systems  

E-Print Network (OSTI)

This paper presents a model to calculate the reliability and availability of heating, ventilation and air conditioning systems. The reliability is expressed in the terms of reliability, maintainability and decision capability. These terms are a...

Myrefelt, S.

2004-01-01T23:59:59.000Z

342

Arbitrage free cointegrated models in gas and oil future markets  

E-Print Network (OSTI)

In this article we present a continuous time model for natural gas and crude oil future prices. Its main feature is the possibility to link both energies in the long term and in the short term. For each energy, the future returns are represented as the sum of volatility functions driven by motions. Under the risk neutral probability, the motions of both energies are correlated Brownian motions while under the historical probability, they are cointegrated by a Vectorial Error Correction Model. Our approach is equivalent to defining the market price of risk. This model is free of arbitrage: thus, it can be used for risk management as well for option pricing issues. Calibration on European market data and numerical simulations illustrate well its behavior.

Benmenzer, Grégory; Jérusalem, Céline

2007-01-01T23:59:59.000Z

343

Reconstruction of f-essence and fermionic Chaplygin gas models of dark energy  

E-Print Network (OSTI)

Recently, it was proposed a new fermionic model of dark energy, the so-called f-essence. In this work, we explicitly reconstruct the different f-essence models. In particular, these models include the fermionic Chaplygin gas and the fermionic generalized Chaplygin gas models of dark energy. We also derive the equation of state parameter of the selected f-essence models.

P. Tsyba; K. Yerzhanov; K. Esmakhanova; I. Kulnazarov; G. Nugmanova; R. Myrzakulov

2011-03-30T23:59:59.000Z

344

Reactive Transport Modeling of Acid Gas Generation and Condensation  

SciTech Connect

Pulvirenti et al. (2004) recently conducted a laboratory evaporation/condensation experiment on a synthetic solution of primarily calcium chloride. This solution represents one potential type of evaporated pore water at Yucca Mountain, Nevada, a site proposed for geologic storage of high-level nuclear waste. These authors reported that boiling this solution to near dryness (a concentration factor >75,000 relative to actual pore waters) leads to the generation of acid condensate (pH 4.5) presumably due to volatilization of HCl (and minor HF and/or HNO{sub 3}). To investigate the various processes taking place, including boiling, gas transport, and condensation, their experiment was simulated by modifying an existing multicomponent and multiphase reactive transport code (TOUGHREACT). This code was extended with a Pitzer ion-interaction model to deal with high ionic strength. The model of the experiment was set-up to capture the observed increase in boiling temperature (143 C at {approx}1 bar) resulting from high concentrations of dissolved salts (up to 8 m CaCl{sub 2}). The computed HCI fugacity ({approx} 10{sup -4} bars) generated by boiling under these conditions is not sufficient to lower the pH of the condensate (cooled to 80 and 25 C) down to observed values unless the H{sub 2}O mass fraction in gas is reduced below {approx}10%. This is because the condensate becomes progressively diluted by H{sub 2}O gas condensation. However, when the system is modeled to remove water vapor, the computed pH of instantaneous condensates decreases to {approx}1.7, consistent with the experiment (Figure 1). The results also show that the HCl fugacity increases, and calcite, gypsum, sylvite, halite, MgCl{sub 2}4H{sub 2}O and CaCl{sub 2} precipitate sequentially with increasing concentration factors.

G. Zhahg; N. Spycher; E. Sonnenthal; C. Steefel

2005-01-25T23:59:59.000Z

345

Mathematical model of gas plasma applied to chronic wounds  

SciTech Connect

Chronic wounds are a major burden for worldwide health care systems, and patients suffer pain and discomfort from this type of wound. Recently gas plasmas have been shown to safely speed chronic wounds healing. In this paper, we develop a deterministic mathematical model formulated by eight-species reaction-diffusion equations, and use it to analyze the plasma treatment process. The model follows spatial and temporal concentration within the wound of oxygen, chemoattractants, capillary sprouts, blood vessels, fibroblasts, extracellular matrix material, nitric oxide (NO), and inflammatory cell. Two effects of plasma, increasing NO concentration and reducing bacteria load, are considered in this model. The plasma treatment decreases the complete healing time from 25 days (normal wound healing) to 17 days, and the contributions of increasing NO concentration and reducing bacteria load are about 1/4 and 3/4, respectively. Increasing plasma treatment frequency from twice to three times per day accelerates healing process. Finally, the response of chronic wounds of different etiologies to treatment with gas plasmas is analyzed.

Wang, J. G.; Liu, X. Y.; Liu, D. W.; Lu, X. P. [State Key Lab of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, WuHan, HuBei 430074 (China)] [State Key Lab of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, WuHan, HuBei 430074 (China); Zhang, Y. T. [Shandong Provincial Key Lab of UHV Technology and Gas Discharge Physics, School of Electrical Engineering, Shandong University, Jinan, Shandong Province 250061 (China)] [Shandong Provincial Key Lab of UHV Technology and Gas Discharge Physics, School of Electrical Engineering, Shandong University, Jinan, Shandong Province 250061 (China)

2013-11-15T23:59:59.000Z

346

Development of New HVAC Design Tools: Search for the Holy Grail of  

NLE Websites -- All DOE Office Websites (Extended Search)

Development of New HVAC Design Tools: Search for the Holy Grail of Development of New HVAC Design Tools: Search for the Holy Grail of Ventilation Research Speaker(s): Jelena Srebric Date: January 29, 2004 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: William Fisk HVAC systems are very important to our wellbeing, energy, and the environment. Current design tools are typically supported by basic knowledge, and keep us at arm's length from the many practical problems. The design paradigm has been shifted several times in the past from thermal comfort, energy conservation, health concerns, and now probably to security issues. Each of the shift has required better design tools of HVAC systems.A team led by Dr. Jelena Srebric at the Department of Architecture, the Penn State University (PSU) is developing new HVAC design tools to meet

347

Gas-Phase Diffusion in Porous Media: Comparison of Models Stephen W. Webb  

Office of Scientific and Technical Information (OSTI)

Gas-Phase Diffusion in Porous Media: Comparison of Models Gas-Phase Diffusion in Porous Media: Comparison of Models Stephen W. Webb Sandia National Laboratories Albuquerque, New Mexico 87 185 ABSTRACT Two models are commonly used to analyze gas- phase diffusion in porous media in the presence of advection, the Advective-Dispersive Model (ADM) and the Dusty-gas Model (DGM). The ADM, which is used in TOUGH2, is based on a simple linear addition of advection calculated by Darcy's law and ordinary diffusion using Fick's law with a porosity- tortuosity-gas saturation multiplier to account for the porous medium. Another approach for gas-phase transport in porous media is the Dusty-Gas Model. This model applies the kinetic theory of gases to the gaseous components and the porous media (or "dust") to combine transport due to diffusion and

348

A Heating Model for the Millennium Gas Run  

E-Print Network (OSTI)

The comparison between observations of galaxy clusters thermo-dynamical properties and theoretical predictions suggests that non-gravitational heating needs to be added into the models. We implement an internally self-consistent heating scheme into GADGET-2 for the third (and fourth) run of the Millennium gas project (Pearce et al. in preparation), a set of four hydrodynamical cosmological simulations with N=2(5x10^8) particles and with the same volume (L=500 h-1 Mpc) and structures as the the N-body Millennium Simulation (Springel et al. 2005). Our aim is to reproduce the observed thermo-dynamical properties of galaxy clusters.

L. Gazzola; F. R. Pearce

2006-11-22T23:59:59.000Z

349

Generalized Cosmic Chaplygin Gas Model with or without Interaction  

E-Print Network (OSTI)

Recently developed Generalized Cosmic Chaplygin gas (GCCG) is studied as an unified model of dark matter and dark energy. To explain the recent accelerating phase, the Universe is assumed to have a mixture of radiation and GCCG. The mixture is considered for without or with interaction. Solutions are obtained for various choices of the parameters and trajectories in the plane of the statefinder parameters and presented graphically. For particular choice of interaction parameter, we have shown the role of statefinder parameters in various cases for the evolution of the Universe.

Writambhara Chakraborty; Ujjal Debnath; Subenoy Chakraborty

2007-11-01T23:59:59.000Z

350

Modeling of multiphase behavior for gas flooding simulation.  

E-Print Network (OSTI)

??Miscible gas flooding is a common method for enhanced oil recovery. Reliable design of miscible gas flooding requires compositional reservoir simulation that can accurately predict… (more)

Okuno, Ryosuke, 1974-

2011-01-01T23:59:59.000Z

351

Analysis of models for induced gas flow in the unsaturated zone Kehua You,1  

E-Print Network (OSTI)

Analysis of models for induced gas flow in the unsaturated zone Kehua You,1 Hongbin Zhan,1 term are frequently employed in modeling the induced gas flow in an unsaturated zone underlying a leaky 2011. [1] Accurate description of induced gas flow in an unsaturated zone is indispensable

Zhan, Hongbin

352

Source attenuating HVAC equipment—Just the facts  

Science Journals Connector (OSTI)

Current classroom designs range from NC 63 to NC 25. The ASA/ANSI 12.60 Classroom Standard sets a relatively low background sound requirement for classrooms. Achieving 12.60 levels economically requires the maximum in source sound attenuation. This paper will provide a manufacturer’s perspective on current and low noiseHVAC products and the resulting classroomsound levels. Predictive acoustics software will be used to predict the space sound power level and some indication of equipment cost will be provided in order to assist designers in what is the best approach to low noiseclassroom design.

2004-01-01T23:59:59.000Z

353

Decomposition of formaldehyde by EPD photocatalyst filters in HVAC  

Science Journals Connector (OSTI)

This study used electrophoretic deposition (EPD) to apply titanium oxide (TiO2) coating on stainless steel filters and investigated the effectiveness of photocatalytic oxidation of formaldehyde by TiO2 under various conditions of heating ventilation air conditioning (HVAC). The results showed photocatalytic efficiency could reach 35.59% at 21 °C and 36.39% at 26 °C with 7 photocatalyst filters and 5 UVC lamps, the overall efficiency of formaldehyde removal of 52.37% at 21 °C, and 56.8% at 26 °C. By all experimental data can be found that the temperature for the photocatalytic performance is not obvious in the range of this study.

Chien-Chih Chen; Ching-Song Jwo; Tun-Ping Teng

2011-01-01T23:59:59.000Z

354

Natural gas transmission and distribution model of the National Energy Modeling System  

SciTech Connect

The Natural Gas Transmission and Distribution Model (NGTDM) is the component of the National Energy Modeling System (NEMS) that is used to represent the domestic natural gas transmission and distribution system. NEMS was developed in the Office of Integrated Analysis and Forecasting of the Energy Information Administration (EIA). NEMS is the third in a series of computer-based, midterm energy modeling systems used since 1974 by the EIA and its predecessor, the Federal Energy Administration, to analyze domestic energy-economy markets and develop projections. From 1982 through 1993, the Intermediate Future Forecasting System (IFFS) was used by the EIA for its analyses, and the Gas Analysis Modeling System (GAMS) was used within IFFS to represent natural gas markets. Prior to 1982, the Midterm Energy Forecasting System (MEFS), also referred to as the Project Independence Evaluation System (PIES), was employed. NEMS was developed to enhance and update EIA`s modeling capability by internally incorporating models of energy markets that had previously been analyzed off-line. In addition, greater structural detail in NEMS permits the analysis of a broader range of energy issues. The time horizon of NEMS is the midterm period (i.e., through 2015). In order to represent the regional differences in energy markets, the component models of NEMS function at regional levels appropriate for the markets represented, with subsequent aggregation/disaggregation to the Census Division level for reporting purposes.

NONE

1997-02-01T23:59:59.000Z

355

PV modules, with a life measured in decades, will typically be in place longer than the outdoor unit of a HVAC system.  

E-Print Network (OSTI)

unit of a HVAC system. When the performance of an HVAC system deteriorates, it is usually inspected remain installed on the roof even after the system is no longer being used. Although HVAC units have only jumpers and screws effectively bond all parts of the listed device together. HVAC components are typically

Johnson, Eric E.

356

Investigations of swirl flames in a gas turbine model combustor  

SciTech Connect

The thermochemical states of three swirling CH{sub 4}/air diffusion flames, stabilized in a gas turbine model combustor, were investigated using laser Raman scattering. The flames were operated at different thermal powers and air/fuel ratios and exhibited different flame behavior with respect to flame instabilities. They had previously been characterized with respect to their flame structures, velocity fields, and mean values of temperature, major species concentrations, and mixture fraction. The single-pulse multispecies measurements presented in this article revealed very rapid mixing of fuel and air, accompanied by strong effects of turbulence-chemistry interactions in the form of local flame extinction and ignition delay. Flame stabilization is accomplished mainly by hot and relatively fuel-rich combustion products, which are transported back to the flame root within an inner recirculation zone. The flames are not attached to the fuel nozzle, and are stabilized approximately 10 mm above the fuel nozzle, where fuel and air are partially premixed before ignition. The mixing and reaction progress in this area are discussed in detail. The flames are short (<50 mm), especially that exhibiting thermoacoustic oscillations, and reach a thermochemical state close to adiabatic equilibrium at the flame tip. The main goals of this article are to outline results that yield deeper insight into the combustion of gas turbine flames and to establish an experimental database for the validation of numerical models.

Meier, W.; Duan, X.R.; Weigand, P. [Institut fuer Verbrennungstechnik, Deutsches Zentrum fuer Luft- und Raumfahrt (DLR), Pfaffenwaldring 38, D-70569 Stuttgart (Germany)

2006-01-01T23:59:59.000Z

357

Modeling and Analysis of Natural Gas and Gasoline In A High Compressio...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

and Analysis of Natural Gas and Gasoline In A High Compression Ratio High Efficiency ICRE Modeling and Analysis of Natural Gas and Gasoline In A High Compression Ratio High...

358

First cosmological constraints on the Superfluid Chaplygin gas model  

E-Print Network (OSTI)

In this work we set observational constraints of the Superfluid Chaplygin gas model, which gives a unified description of the dark sector of the Universe as a Bose-Einstein condensate (BEC) that behaves as dark energy (DE) while it is in the ground state and as dark matter (DM) when it is in the excited state. We first show and perform the various steps leading to a form of the equations suitable for the observational tests to be carried out. Then, by using a Markov Chain Monte Carlo (MCMC) code, we constrain the model with a sample of cosmology-independent long gamma-ray bursts (LGRBs) calibrated using their Type I Fundamental Plane, as well as the Union2.1 set and observational Hubble parameter data. In this analysis, using our cosmological constraints, we sketch the effective equation of state parameter and deceleration parameter, and we also obtain the redshift of the transition from deceleration to acceleration: $z_t$.

Lazkoz, Ruth; Salzano, Vincenzo

2012-01-01T23:59:59.000Z

359

First cosmological constraints on the Superfluid Chaplygin gas model  

E-Print Network (OSTI)

In this work we set observational constraints of the Superfluid Chaplygin gas model, which gives a unified description of the dark sector of the Universe as a Bose-Einstein condensate (BEC) that behaves as dark energy (DE) while it is in the ground state and as dark matter (DM) when it is in the excited state. We first show and perform the various steps leading to a form of the equations suitable for the observational tests to be carried out. Then, by using a Markov Chain Monte Carlo (MCMC) code, we constrain the model with a sample of cosmology-independent long gamma-ray bursts (LGRBs) calibrated using their Type I Fundamental Plane, as well as the Union2.1 set and observational Hubble parameter data. In this analysis, using our cosmological constraints, we sketch the effective equation of state parameter and deceleration parameter, and we also obtain the redshift of the transition from deceleration to acceleration: $z_t$.

Ruth Lazkoz; Ariadna Montiel; Vincenzo Salzano

2012-11-15T23:59:59.000Z

360

Observational Constraints of New Variable Modified Chaplygin Gas Model  

E-Print Network (OSTI)

Assuming the flat FRW universe in Einstein's gravity filled with New Variable Modified Chaplygin gas (NVMCG) dark energy and dark matter having negligible pressure. In this research work we analyze the viability on the basis of recent observation. Hubble parameter $H$ is expressed in terms of the observable parameters $H_0$, $\\Omega_m^0$ and the model parameters $A_0$, $B_0$, $C_0$, $m$, $n$, $\\alpha$ and the red shift parameter $z$. Here we find a best fitted parameter range of $A_0$, $B_0$ keeping $0\\leq \\alpha \\leq 1$ and using Stern data set (12 points) by minimizing the $\\chi^2$ test at 66%, 90% and 99% confidence levels. Next we do the joint analysis with BAO and CMB observations. Again evaluating the distance modulus $\\mu(z)$ vs redshift ($z$) curve obtained in the model NVMCG with dark matter with the best fitted value of the parameters and comparing with that derived from the union2 compilation data.

Jhumpa Bhadra; Ujjal Debnath

2012-11-09T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Bayesian Hierarchical Models for aerospace gas turbine engine prognostics  

Science Journals Connector (OSTI)

Abstract Improved prognostics is an emerging requirement for modern health monitoring that aims to increase the fidelity of failure-time predictions by the appropriate use of sensory and reliability information. In the aerospace industry, it is a key technology to maximise aircraft availability, offering a route to increase time in-service and to reduce operational disruption through improved asset management. An aircraft engine is a complex system comprising multiple subsystems that have dependent interactions so it is difficult to construct a model of its degradation dynamics based on physical principles. This complexity suggests that a statistically robust methodology for handling large quantities of real-time data would be more appropriate. In this work, therefore, a Bayesian approach is taken to exploit fleet-wide data from multiple assets to perform probabilistic estimation of remaining useful life for civil aerospace gas turbine engines. The paper establishes a Bayesian Hierarchical Model to perform inference and inform a probabilistic model of remaining useful life. Its performance is compared with that of an existing Bayesian non-Hierarchical Model and is found to be superior in typical (heterogeneous) scenarios. The techniques use Bayesian methods to combine two sources of information: historical in-service data across the engine fleet and once per-flight transmitted performance measurement from the engine(s) under prognosis. The proposed technique provides predictive results within well defined uncertainty bounds and demonstrates several advantages of the hierarchical variant’s ability to integrate multiple unit data to address realistic prognostic challenges. This is illustrated by an example from a civil aerospace gas turbine fleet data.

Martha A. Zaidan; Robert F. Harrison; Andrew R. Mills; Peter J. Fleming

2015-01-01T23:59:59.000Z

362

Fouling of HVAC fin and tube heat exchangers  

SciTech Connect

Fin and tube heat exchangers are used widely in residential, commercial and industrial HVAC applications. Invariably, indoor and outdoor air contaminants foul these heat exchangers. This fouling can cause decreased capacity and efficiency of the HVAC equipment as well as indoor air quality problems related to microbiological growth. This paper describes laboratory studies to investigate the mechanisms that cause fouling. The laboratory experiments involve subjecting a 4.7 fins/cm (12 fins/inch) fin and tube heat exchanger to an air stream that contains monodisperse particles. Air velocities ranging from 1.5-5.2 m/s (295 ft/min-1024 ft/min) and particle sizes from 1--8.6 {micro}m are used. The measured fraction of particles that deposit as well as information about the location of the deposited material indicate that particles greater than about 1 {micro}m contribute to fouling. These experimental results are used to validate a scaling analysis that describes the relative importance of several deposition mechanisms including impaction, Brownian diffusion, turbophoresis, thermophoresis, diffusiophoresis, and gravitational settling. The analysis is extended to apply to different fin spacings and particle sizes typical of those found in indoor air.

Siegel, Jeffrey; Carey, Van P.

2001-07-01T23:59:59.000Z

363

Sound quality descriptors for HVAC equipment from ARI Standards  

Science Journals Connector (OSTI)

The Air Conditioning and Refrigeration Institute (ARI) has several standards that provide methods to evaluate the sound quality of heating ventilating and air?conditioning (HVAC) equipment. These include Standard 270 Sound rating of outdoor unitary equipment Standard 350 Sound rating of non?ducted indoor air?conditioning equipment and Standard 1140P Procedures for evaluating sound quality of HVAC equipment. The preferred method in these standards is best described in Standard 1140P which uses one?third octave band sound power levels that are weighted to adjust for the sensitivity to frequency distribution and presence of tones and are then converted to a single number sound quality indicator. The tone adjustment is based on the projection of a given one?third octave band level relative to the average of the adjacent one?third octave bands. An alternate use of Zwicker method B to determine loudness and loudness level is also provided in ARI Standard 1140P. These standards provide a convenient method by which complex sounds for similar products may be compared.

2003-01-01T23:59:59.000Z

364

EIA - The National Energy Modeling System: An Overview 2003-Oil and Gas  

Gasoline and Diesel Fuel Update (EIA)

Oil and Gas Supply Module Oil and Gas Supply Module The National Energy Modeling System: An Overview 2003 Oil and Gas Supply Module The oil and gas supply module (OGSM) consists of a series of process submodules that project the availability of: Domestic crude oil production and dry natural gas production from onshore, offshore, and Alaskan reservoirs Imported pipeline–quality gas from Mexico and Canada Imported liquefied natural gas. Figure 12. Oil and Gas Supply Module Regions. Need help, contact the National Energy Information Center at 202-202-586-8800. Figure 13. Oil and Gas Suppply Module Structure. Need help, contact the National Energy Information Center at 202-586-8800. Oil and Gas Supply Module Table. Need help, contact the National Energy Information Center at 202-586-8800.

365

The modelling of biochemical-thermal coupling effect on gas generation and transport in MSW landfill  

Science Journals Connector (OSTI)

The landfill gas generation was investigated based on the theories of the thermodynamics, microbial dynamics and chemical dynamics. The coupling model was developed for describing the gas transport and heat release. And the relationship between the gas generation rate and the temperature was proposed. The parameters in the gas generation model were obtained by bioreactor test in order to evaluate the volume of gas production of the Erfeishan landfill in China. The simulation results shown that the operating life of the landfill will be overestimated if the model does not consider the thermal effect during degradation of the solid substrate.

Liu Lei; Liang Bing; Xue Qiang; Zhao Ying; Yang Chun

2011-01-01T23:59:59.000Z

366

Highly covariant quantum lattice gas model of the Dirac equation  

E-Print Network (OSTI)

We revisit the quantum lattice gas model of a spinor quantum field theory-the smallest scale particle dynamics is partitioned into unitary collide and stream operations. The construction is covariant (on all scales down to a small length {\\ell} and small time {\\tau} = c {\\ell}) with respect to Lorentz transformations. The mass m and momentum p of the modeled Dirac particle depend on {\\ell} according to newfound relations m = mo cos (2{\\pi}{\\ell}/{\\lambda}) and p = (h/2{\\pi}{\\ell}) sin(2{\\pi}{\\ell}/{\\lambda}), respectively, where {\\lambda} is the Compton wavelength of the modeled particle. These relations represent departures from a relativistically invariant mass and the de Broglie relation-when taken as quantifying numerical errors the model is physically accurate when {\\ell} {\\ll} {\\lambda}. Calculating the vacuum energy in the special case of a massless spinor field, we find that it vanishes (or can have a small positive value) for a sufficiently large wave number cutoff. This is a marked departure from the usual behavior of such a massless field.

Jeffrey Yepez

2011-06-03T23:59:59.000Z

367

Building HVAC Requirements Overview Page 4-1 4 Building HVAC Requirements  

E-Print Network (OSTI)

heating, radiant floor systems, evaporative cooling, gas cooling, ground-source heat pumps, and wood space requirements for additions to existing dwellings and for alterations to existing heating and cooling systems packages. Package C permits electric resistance space heating, but requires significantly greater

368

Modeling of gas-solid flow in a CFB riser based on computational particle fluid dynamics  

Science Journals Connector (OSTI)

A three-dimensional model for gas-solid flow in a circulating fluidized bed (CFB) riser was developed based on computational particle ... experimental data validated the CPFD model for the CFB riser. The model pr...

Yinghui Zhang; Xingying Lan; Jinsen Gao

2012-12-01T23:59:59.000Z

369

Optimization Models for Optimal Investment, Drilling, and Water Management in Shale Gas Supply Chains  

Science Journals Connector (OSTI)

Abstract This paper provides an overview of recent optimization models for shale gas production. We first describe a new mixed-integer optimization model for the design of shale gas infrastructures. It is aimed at optimizing the number of wells to drill, size and location of new gas processing plants, section and length of pipelines for gathering raw gas, delivering dry gas and natural gas liquids, power of gas compressors, and planning of freshwater consumption for well drilling and fracturing. We also describe a detailed operational mixed-integer linear model to optimize life cycle water use for well pads. The objective of the model is to determine the fracturing schedule that minimizes costs for freshwater consumption, transportation, treatment, storage, and disposal.

Ignacio E. Grossmann; Diego C. Cafaro; Linlin Yang

2014-01-01T23:59:59.000Z

370

The Polyakov loop and the hadron resonance gas model  

E-Print Network (OSTI)

The Polyakov loop has been used repeatedly as an order parameter in the deconfinement phase transition in QCD. We argue that, in the confined phase, its expectation value can be represented in terms of hadronic states, similarly to the hadron resonance gas model for the pressure. Specifically, L(T) \\approx 1/2\\sum_\\alpha g_\\alpha \\,e^(-\\Delta_\\alpha/T), where g_\\alpha are the degeneracies and \\Delta_\\alpha are the masses of hadrons with exactly one heavy quark (the mass of the heavy quark itself being subtracted). We show that this approximate sum rule gives a fair description of available lattice data with N_f=2+1 for temperatures in the range 150MeVmodels. For temperatures below 150MeV different lattice results disagree. One set of data can be described if exotic hadrons are present in the QCD spectrum while other sets do not require such states.

E. Megias; E. Ruiz Arriola; L. L. Salcedo

2012-04-11T23:59:59.000Z

371

The National Energy Modeling System: An Overview 2000 - Natural Gas  

Gasoline and Diesel Fuel Update (EIA)

natural gas transmission and distribution module (NGTDM) of NEMS represents the natural gas market and determines regional market-clearing prices for natural gas supplies and for end-use consumption, given the information passed from other NEMS modules. A transmission and distribution network (Figure 15), composed of nodes and arcs, is used to simulate the interregional flow and pricing of gas in the contiguous United States and Canada in both the peak (December through March) and offpeak (April through November) period. This network is a simplified representation of the physical natural gas pipeline system and establishes the possible interregional flows and associated prices as gas moves from supply sources to end users. natural gas transmission and distribution module (NGTDM) of NEMS represents the natural gas market and determines regional market-clearing prices for natural gas supplies and for end-use consumption, given the information passed from other NEMS modules. A transmission and distribution network (Figure 15), composed of nodes and arcs, is used to simulate the interregional flow and pricing of gas in the contiguous United States and Canada in both the peak (December through March) and offpeak (April through November) period. This network is a simplified representation of the physical natural gas pipeline system and establishes the possible interregional flows and associated prices as gas moves from supply sources to end users. Figure 15. Natural Gas Transmission and Distribution Module Network

372

Statistical Modeling of Corrosion Failures in Natural Gas Transmission Pipelines  

E-Print Network (OSTI)

Natural gas pipelines are a critical component of the U.S. energy infrastructure. The safety of these pipelines plays a key role for the gas industry. Therefore, the understanding of failure characteristics and their consequences are very important...

Cobanoglu, Mustafa Murat

2014-03-28T23:59:59.000Z

373

System Modeling of Gas Engine Driven Heat Pump  

SciTech Connect

To improve the system performance of the GHP, modeling and experimental study has been made by using desiccant system in cooling operation (particularly in high humidity operations) and suction line waste heat recovery to augment heating capacity and efficiency. The performance of overall GHP system has been simulated by using ORNL Modulating Heat Pump Design Software, which is used to predict steady-state heating and cooling performance of variable-speed vapor compression air-to-air heat pumps for a wide range of operational variables. The modeling includes: (1) GHP cycle without any performance improvements (suction liquid heat exchange and heat recovery) as a baseline (both in cooling and heating mode), (2) the GHP cycle in cooling mode with desiccant system regenerated by waste heat from engine incorporated, (3) GHP cycle in heating mode with heat recovery (recovered heat from engine). According to the system modeling results, by using desiccant system regenerated by waste heat from engine, the SHR can be lowered to 40%. The waste heat of the gas engine can boost the space heating efficiency by 25% in rated operating conditions.

Mahderekal, Isaac [Oak Ridge National Laboratory (ORNL)] [Oak Ridge National Laboratory (ORNL); Shen, Bo [ORNL] [ORNL; Vineyard, Edward [Oak Ridge National Laboratory (ORNL)] [Oak Ridge National Laboratory (ORNL)

2012-01-01T23:59:59.000Z

374

Modeling of residual service life of gas turbine rotors for minimizing replacement costs  

Science Journals Connector (OSTI)

One of the most catastrophic failures observed in gas turbine powered electrical powerplants is the fracture of the turbine rotor. A simplified model consisting of 3 macro-elements is suggested to model the dynamical behavior of the shaft with a propagating ... Keywords: crack propagation, gas-turbine, modeling, power-plant, replacement costs

Eusebia Zouridaki; Vasilios Spitas; Christos Spitas

2007-01-01T23:59:59.000Z

375

Optimal Location of Compressed Natural Gas (CNG) Refueling Station Using the Arc Demand Coverage Model  

Science Journals Connector (OSTI)

In this paper a model that locates Compressed Natural Gas (CNG) refueling stations to cover the full volume of vehicle flows is developed and applied. The model inputs consist of a road network include nodes and arcs, the volume of vehicle flows between ... Keywords: Compressed Natural Gas, Arc Demand Coverage Model, Optimal Location, Network

Abtin Boostani; Reza Ghodsi; Ali Kamali Miab

2010-05-01T23:59:59.000Z

376

A multiple temperature kinetic model and its application to micro-scale gas flow simulations  

E-Print Network (OSTI)

A multiple temperature kinetic model and its application to micro-scale gas flow simulations model, micro-scale flows. 1. Introduction Gas flows can be classified according to the flow regimes_pku@yahoo.com.cn Abstract This paper presents a numerical approach to solve the multiple temperature kinetic model (MTKM

Xu, Kun

377

Cosmological implications of interacting polytropic gas dark energy model in non-flat universe  

E-Print Network (OSTI)

The polytropic gas model is investigated as an interacting dark energy scenario. The cosmological implications of the model including the evolution of EoS parameter $w_{\\Lambda}$, energy density $\\Omega_{\\Lambda}$ and deceleration parameter $q$ are investigated. We show that, depending on the parameter of model, the interacting polytropic gas can behave as a quintessence or phantom dark energy. In this model, the phantom divide is crossed from below to up. The evolution of $q$ in the context of polytropic gas dark energy model represents the decelerated phase at the early time and accelerated phase later. The singularity of this model is also discussed. Eventually, we establish the correspondence between interacting polytropic gas model with tachyon, K-essence and dilaton scalar fields. The potential and the dynamics of these scalar field models are reconstructed according to the evolution of interacting polytropic gas.

M. Malekjani; A. Khodam-Mohammadi; M. Taji

2010-12-13T23:59:59.000Z

378

Dissolved Gas in the Snake and Columbia Rivers Modeled by CRiSP  

E-Print Network (OSTI)

Dissolved Gas in the Snake and Columbia Rivers 1969-1984 Modeled by CRiSP Pamela Shaw Columbia Basin Research School of Fisheries, UW #12;Introduction These dissolved gas profiles for 1969-1984 were created using CRiSP and historic spill and flow data. In CRiSP the gas going into the tailwater

Washington at Seattle, University of

379

Modeling the Relative GHG Emissions of Conventional and Shale Gas Production  

Science Journals Connector (OSTI)

Modeling the Relative GHG Emissions of Conventional and Shale Gas Production ... Recent reports show growing reserves of unconventional gas are available and that there is an appetite from policy makers, industry, and others to better understand the GHG impact of exploiting reserves such as shale gas. ... The results show which parameters have most influence on GHG emissions intensity and which are relatively unimportant. ...

Trevor Stephenson; Jose Eduardo Valle; Xavier Riera-Palou

2011-11-15T23:59:59.000Z

380

American Institute of Aeronautics and Astronautics Modeling the motion of pyrolysis gas through charring  

E-Print Network (OSTI)

1 American Institute of Aeronautics and Astronautics Modeling the motion of pyrolysis gas through problem with gas motion through the porous media employing finite element based Galerkin and Discontinuous t = time Subscripts c = char g = pyrolysis gas r = resin I. Introduction pace vehicles enter earth's (or

Roy, Subrata

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

A one-dimensional model of vertical gas plume migration through a heterogeneous porous medium  

E-Print Network (OSTI)

A one-dimensional model of vertical gas plume migration through a heterogeneous porous medium and consequent global warming. Ideally, the injected greenhouse gas stays in the injection zone for a geologic or inadvertently created conduits in the cap rock may result in a gas leakage from primary storage. Even

Patzek, Tadeusz W.

382

Mathematical modeling of heterogeneous detonation in gas suspensions of aluminum and coal-dust particles  

SciTech Connect

Results of investigations performed by the authors in the field of theoretical and numerical modeling of heterogeneous detonation of reacting gas suspensions since 2005 are systematized.

Fedorov, A.V.; Fomin, V.M.; Khmel, T.A. [Russian Academy of Sciences, Novosibirsk (Russian Federation)

2009-07-15T23:59:59.000Z

383

Modelling and Numerical Simulation of Gas Migration in a Nuclear Waste Repository  

E-Print Network (OSTI)

We present a compositional compressible two-phase, liquid and gas, flow model for numerical simulations of hydrogen migration in deep geological radioactive waste repository. This model includes capillary effects and the gas diffusivity. The choice of the main variables in this model, Total or Dissolved Hydrogen Mass Concentration and Liquid Pressure, leads to a unique and consistent formulation of the gas phase appearance and disappearance. After introducing this model, we show computational evidences of its adequacy to simulate gas phase appearance and disappearance in different situations typical of underground radioactive waste repository.

Bourgeat, Alain; Smai, Farid

2010-01-01T23:59:59.000Z

384

Basic Reaction Model of Automobile Exhaust Gas Treatment over Pt?Rh Catalyst  

Science Journals Connector (OSTI)

Basic Reaction Model of Automobile Exhaust Gas Treatment over Pt?Rh Catalyst ... The reactor is heated by a three-section electric furnace. ...

Motoaki Kawase; Hiroyasu Fujitsuka; Hitoshi Nakanishi; Tatsuya Yoshikawa; Kouichi Miura

2010-09-02T23:59:59.000Z

385

EIA - The National Energy Modeling System: An Overview 2003-Natural Gas  

Gasoline and Diesel Fuel Update (EIA)

Natural Gas Transmission and Distribution Module Natural Gas Transmission and Distribution Module The National Energy Modeling System: An Overview 2003 Natural Gas Transmission and Distribution Module Figure 15. Natural Gas Transmission and Distribution Module Structure. Need help, contact the National Energy Information Center at 202-586-8800. Figure 16. Natural Gas Transmission and distribution Module Network. Need help, contact the National Energy Information Center at 202-586-8800. Natural Gas Transmission and distribution Module Table. Need help, contact the National Energy Information Center at 202-586-8800. The natural gas transmission and distribution module (NGTDM) of NEMS represents the natural gas market and determines regional market–clearing prices for natural gas supplies and for end–use consumption, given the

386

Using multi-layer models to forecast gas flow rates in tight gas reservoirs  

E-Print Network (OSTI)

.2 Typical Tight Gas Sand Log Interval (Cotton Valley Formation)........................... 3 2.1 Type of Decline Curves by Arps........................................................................... 11 2.2 Fetkovich Type Curves... ......................................................................................... 14 2.3 Fetkovich Type Curves for Gas Wells .................................................................. 15 3.1 Plan View of Hydraulic Fracture and Grid System...............................................30 3.2 History Match...

Jerez Vera, Sergio Armando

2007-04-25T23:59:59.000Z

387

HVAC Right-Sizing Part 1: Calculating Loads  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Building America Building America Presented by: Mike Gestwick - National Renewable Energy Laboratory Arlan Burdick, Anthony Grisolia - IBACOS, a Building America Research Team HVAC Right-Sizing Part 1: Calculating Loads Thursday, April 28 11:00 a.m. - 12:00 p.m. Eastern Building Technologies Program Mike Gestwick michael.gestwick@nrel.gov Building America: Introduction April 28, 2011 Introduction to Building America * Reduce energy use in new and existing residential buildings * Promote building science and systems engineering / integration approach * "Do no harm": Ensure safety, health and durability are maintained or improved * Accelerate adoption of high performance technologies www.buildingamerica.gov 15 Industry Research Teams Habitat Cost Effective Energy Retrofit Program

388

Fight Fall Allergies and Save Energy by Checking Your HVAC System |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fight Fall Allergies and Save Energy by Checking Your HVAC System Fight Fall Allergies and Save Energy by Checking Your HVAC System Fight Fall Allergies and Save Energy by Checking Your HVAC System October 15, 2012 - 3:19pm Addthis Change your furnace filter to help keep allergies at bay and keep your furnace and air conditioner running efficiently. | Photo courtesy of ©iStockphoto.com/JaniceRichard. Change your furnace filter to help keep allergies at bay and keep your furnace and air conditioner running efficiently. | Photo courtesy of ©iStockphoto.com/JaniceRichard. Elizabeth Spencer Communicator, National Renewable Energy Laboratory What does this mean for me? Change your furnace filters every month or two to keep your HVAC equipment operating efficiently. I have unbelievably horrible fall allergies. I've never figured out what

389

What are the Best HVAC Solutions for Low-Load, High Performance Homes?"  

Energy.gov (U.S. Department of Energy (DOE))

This presentation was given at the Summer 2012 DOE Building America meeting on July 26, 2012, and addressed the question What are the best HVAC solutions for low-load, high performance homes?"

390

Building America Webinar: HVAC Right-Sizing Part 1—Calculating Loads  

Energy.gov (U.S. Department of Energy (DOE))

During this webinar, Building America Research Team IBACOS highlighted the key criteria required to create accurate heating and cooling load calculations. Current industry rules of thumb, perceptions and barriers to right-sizing HVAC were also discussed.

391

CO 2 - Based Demand-Controlled Ventilation Control Strategies for Multi-Zone HVAC Systems  

E-Print Network (OSTI)

CO 2-based demand-controlled ventilation DCV strategy offers a great opportunity to reduce energy consumption in HVAC systems while providing the required ventilation. However, implementing CO 2-based DCV under ASHRAE 62.1.2004 through 2010...

Nassif, N.

2011-01-01T23:59:59.000Z

392

Analysis of the HVAC System at the Willow Branch Intermediate School  

E-Print Network (OSTI)

This report presents an analysis of the HVAC system at the Willow Branch Intermediate School for the MEEN 685 class project. The school is located at College Station, Texas. A portion of the school belonged to Oakwood Intermediate School which...

Wei, G.

1997-01-01T23:59:59.000Z

393

Application of Various HVAC Simulation Programs and Visual Tools to Commissioning  

E-Print Network (OSTI)

Various existing HVAC system simulation programs and visualization tools are considered to be potentially powerful tools for commissioning. Although not originally developed as commissioning tools, these programs facilitate the confirmation...

Zheng, M.; Pan, S.

2007-01-01T23:59:59.000Z

394

Computational Study on Thermal Properties of HVAC System with Building Structure Thermal Storage  

E-Print Network (OSTI)

Building structure thermal storage (BSTS) HVAC systems can store heat during nighttime thermal storage operation (nighttime operation hours) by using off-peak electricity and release it in the daytime air-conditioning operation (daytime operation...

Sato, Y.; Sagara, N.; Ryu, Y.; Maehara, K.; Nagai, T.

2007-01-01T23:59:59.000Z

395

DOE Convening Report on Certification of Commercial HVAC and CRE Products  

Energy.gov (U.S. Department of Energy (DOE))

This document is the convening report on the feasibility of a negotiated rulemaking to revise the certification program for commercial HVAC and CRE products published on October 2, 2012.

396

Energy Savings Potential and RD&D Opportunities for Commercial Building HVAC  

Energy.gov (U.S. Department of Energy (DOE))

This Building Technologies Office report assesses heating, ventilation, and air-conditioning (HVAC) technologies for U.S. commercial buildings to identify and provide analysis on 17 priority technology options in various stages of development.

397

Requirements for Commissioning HVAC Systems Using BEMS and Commissioning the BEMS Itself Based on Questionnaire Surveys  

E-Print Network (OSTI)

In this paper the present status and requirements for commissioning of HVAC Systems using Building Energy Management Systems (BEMS) and commissioning the BEMS itself are investigated and summarized. The information presented is based on the results...

Yoshida, H.; Vaezi-Nejad, H.; Choiniere, D.; Wang, F.

2004-01-01T23:59:59.000Z

398

Development of HVAC System Performance Criteria Using Factorial Design and DOE-2 Simulation  

E-Print Network (OSTI)

A new approach is described for the development of Heating, Ventilating, and Air-conditioning (HVAC) System Performance Criteria for the Texas Building Energy Design Standard. This approach integrates a design of experimental methodology and DOE-2...

Hou, D.; Jones, J. W.; Hunn, B. D.; Banks, J. A.

1996-01-01T23:59:59.000Z

399

Energy Savings Potential and RD&D Opportunities for Residential Building HVAC Systems  

Energy.gov (U.S. Department of Energy (DOE))

This report assesses 135 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. residential buildings to identify and provide analysis on 19 priority technology options in various stages of development.

400

Building America Whole-House Solutions for Existing Homes: Inverted Attic Bulkhead for HVAC Ductwork  

Energy.gov (U.S. Department of Energy (DOE))

This occupied test home received a modified truss system to accommodate ductwork within an inverted insulated bulkhead along the attic floor, which saves energy by placing heating, ventilating, and air-conditioning (HVAC) ductwork within the home's thermal boundary.

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

DOE Convening Report on Certification of Commercial HVAC and CRE Products  

NLE Websites -- All DOE Office Websites (Extended Search)

Convening Report on Certification of Commercial HVAC and CRE Products, October 2, 2012 Convening Report on Certification of Commercial HVAC and CRE Products, October 2, 2012 1 U.S. DEPARTMENT OF ENERGY CONVENING REPORT ON THE FEASIBILITY OF A NEGOTIATED RULEMAKING TO REVISE THE CERTIFICATION PROGRAM FOR COMMERCIAL HEATING, VENTILATING AIR CONDITIONING AND COMMERCIAL REFRIGERATION EQUIPMENT October 2, 2012 Alan W. Strasser, Esq., MA Convener

402

A Unified and Integrated Energy Management System for HVAC Spaces and Power House  

E-Print Network (OSTI)

A UNIFIED AND INTEGRATED ENERGY MANAGEMENT SYSTEM FOR HVAC SPACES AND POWER HOUSE A.Kaya The University of Akron Mechanical Engineering Akron,OH 44325 ABSTRACT This paper describes a totally integrated energy management system throughout... the plant and facilities. The equipment involves: the power flant (boilers, cogeneration turbines, chillers); HVAC 0 buildings; air handling and other distribution systems. The energy management system has the architecture for data transmission...

Kaya, A.; Debban, G. D.

403

A Simple Physical Model for the Gas Distribution in Galaxy Clusters  

E-Print Network (OSTI)

The dominant baryonic component of galaxy clusters is hot gas whose distribution is commonly probed through X-ray emission arising from thermal bremsstrahlung. The density profile thus obtained has been traditionally modeled with a beta-profile, a simple function with only three parameters. However, this model is known to be insufficient for characterizing the range of cluster gas distributions, and attempts to rectify this shortcoming typically introduce additional parameters to increase the fitting flexibility. We use cosmological and physical considerations to obtain a family of profiles for the gas with fewer parameters than the beta-model but which better accounts for observed gas profiles over wide radial intervals.

Patej, Anna

2014-01-01T23:59:59.000Z

404

An Efficient Multiperiod MINLP Model for Optimal Planning of Offshore Oil and Gas Field Infrastructure  

Science Journals Connector (OSTI)

An Efficient Multiperiod MINLP Model for Optimal Planning of Offshore Oil and Gas Field Infrastructure ... Offshore oil and gas field development represents a very complex problem and involves multibillion dollar investments and profits (Babusiaux et al.(1)). ... This paper focuses on a nonconvex MINLP model for the strategic/tactical planning of the offshore oil and gas fields, which includes sufficient details to make it useful for realistic oilfield development projects, as well as for extensions to include fiscal and uncertainty considerations. ...

Vijay Gupta; Ignacio E. Grossmann

2012-04-07T23:59:59.000Z

405

Predicting the energy use and operation cost of HVAC air filters  

Science Journals Connector (OSTI)

A model has been developed to predict the energy efficiency and annual operation cost for filters installed in an HVAC air handling system using filter data from standard ASHRAE 52.2-2007 filter tests. Thirty filters from six manufacturers were investigated to determine the most energy efficient and cost effective filtration solutions for an airport installation in Vancouver, Canada. A comparison of the output of the proposed model with the ‘kep’ and Wattage methods was performed to highlight the possible differences in filter choice that would be made using alternative approaches. The outcomes have been shown to differ due to data not incorporated in the older models such as filtration efficiency and particulate concentration. The sensitivity of filter cost to model parameters was also studied. It was found that the concentration of particles in the air stream and the cost of electricity had the largest effect on annual cost of operation. Increasing the concentration of particles in the air stream increases the cost of operating the filter and causes the installation of a prefilter upstream of the primary filter to be more economically attractive. Increasing electricity cost also increases the operation cost but has the reverse effect on attractiveness of prefilter installations.

James F. Montgomery; Sheldon I. Green; Steven N. Rogak; Karen Bartlett

2012-01-01T23:59:59.000Z

406

Mixed Integer Model Predictive Control of Multiple Shale Gas Wells.  

E-Print Network (OSTI)

?? Horizontal wells with multistage hydraulic fracturing are today the most important drilling technology for shale gas extraction. Considered unprofitable before, the production has now… (more)

Nordsveen, Espen T

2012-01-01T23:59:59.000Z

407

Gas Network Optimization: A comparison of Piecewise Linear Models  

E-Print Network (OSTI)

Oct 4, 2014 ... ... and advanced MILP formulations for the gas network optimization in dynamic or in steady-state conditions. ... Search, Browse the Repository.

CARLOS M. CORREA-POSADA

2014-10-04T23:59:59.000Z

408

High Detail Stationary Optimization Models for Gas Networks  

E-Print Network (OSTI)

Oct 15, 2014 ... Abstract: Due to strict regulatory rules in combination with complex nonlinear physics, major gas network operators in Germany and Europe ...

Martin Schmidt

2014-10-15T23:59:59.000Z

409

Design, modelling and control of a gas turbine air compressor .  

E-Print Network (OSTI)

??The production of compressed air constitutes a considerable portion of industrial electrical consumption. An alternative to electrically driven air compression systems is a gas turbine… (more)

WIESE, ASHLEY PETER

2014-01-01T23:59:59.000Z

410

Case study field evaluation of a systems approach to retrofitting a residential HVAC system  

SciTech Connect

This case study focusing on a residence in northern California was undertaken as a demonstration of the potential of a systems approach to HVAC retrofits. The systems approach means that other retrofits that can affect the HVAC system are also considered. For example, added building envelope insulation reduces building loads so that smaller capacity HVAC system can be used. Secondly, we wanted to examine the practical issues and interactions with contractors and code officials required to accomplish the systems approach because it represents a departure from current practice. We identified problems in the processes of communication and installation of the retrofit that led to compromises in the final energy efficiency of the HVAC system. These issues must be overcome in order for HVAC retrofits to deliver the increased performance that they promise. The experience gained in this case study was used to optimize best practices guidelines for contractors (Walker 2003) that include building diagnostics and checklists as tools to assist in ensuring the energy efficiency of ''house as a system'' HVAC retrofits. The best practices guidelines proved to be an excellent tool for evaluating the eight existing homes in this study, and we received positive feedback from many potential users who reviewed and used them. In addition, we were able to substantially improve the energy efficiency of the retrofitted case study house by adding envelope insulation, a more efficient furnace and air conditioner, an economizer and by reducing duct leakage.

Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

2003-09-01T23:59:59.000Z

411

A Planar Anode -Supported Solid Oxide Fuel Cell Model with Internal Reforming of Natural Gas  

E-Print Network (OSTI)

1 A Planar Anode - Supported Solid Oxide Fuel Cell Model with Internal Reforming of Natural Gas of natural gas has been developed. The model simultaneously solves mass, energy transport equations emission level, and multiple fuel utilization. SOFC can operate with various kinds of fuels such as natural

Boyer, Edmond

412

A Three-Dimensional Computational Model of PEM Fuel Cell with Serpentine Gas Channels  

E-Print Network (OSTI)

A Three-Dimensional Computational Model of PEM Fuel Cell with Serpentine Gas Channels by Phong) fuel cell with serpentine gas flow channels is presented in this thesis. This comprehensive model accounts for important transport phenomena in a fuel cell such as heat transfer, mass transfer, electrode

Victoria, University of

413

Modeling, Optimization, and Experimentation with a Two Stage Mixed Gas Cascaded Joule Thomson Cryoprobe  

E-Print Network (OSTI)

Modeling, Optimization, and Experimentation with a Two Stage Mixed Gas Cascaded Joule Thomson-stage Mixed Gas Joule Thomson (MGJT) cycle is capable of providing compact cooling for cryoprobes". A computational model of a commercially available two stage MGJT cryoprobe donated by American Medical Systems

Wisconsin at Madison, University of

414

Validation of a Model of a Resonant Optothermoacoustic Trace Gas Sensor  

E-Print Network (OSTI)

Validation of a Model of a Resonant Optothermoacoustic Trace Gas Sensor N. Petra1, J. Zweck1, S. E, Rice University, Houston, TX 77005, USA E-mail: zweck@umbc.edu Abstract: A model for a resonant. At low concentrations, the molecular dynamics of the trace gas do not influence the signal. © 2010

Minkoff, Susan E.

415

Model-Based Hierarchical Optimal Control Design for HVAC Systems  

E-Print Network (OSTI)

sun on the external sides of the walls in deriving the differential equations of the temperature distribution

Maasoumy, Mehdi; Pinto, Alessandro; Sangiovanni-Vincentelli, Alberto

2014-01-01T23:59:59.000Z

416

Decentralized model predictive control of a multiple evaporator HVAC system  

E-Print Network (OSTI)

Vapor compression cooling systems are the primary method used for refrigeration and air conditioning, and as such are a major component of household and commercial building energy consumption. Application of advanced control techniques...

Elliott, Matthew Stuart

2009-05-15T23:59:59.000Z

417

Comparison of Building Energy Modeling Programs: HVAC Systems  

E-Print Network (OSTI)

Four Pipe Fan Coil; Four Pipe Induction Unit; Heating andTwo Pipe Fan Coil; Two Pipe Induction Unit; Unit Heater;units (AHUs) – four CAV systems, four VAV systems, and one fan coil

Zhou, Xin

2014-01-01T23:59:59.000Z

418

MODELING AND SIMULATION OF HVAC FAULTS IN ENERGYPLUS  

E-Print Network (OSTI)

coefficient as well as increased pressure drop across coil Unintended heating depending on which position the valve

Basarkar, Mangesh

2013-01-01T23:59:59.000Z

419

Estimation of Landfill Gas Generation Rate and Gas Permeability Field of Refuse Using Inverse Modeling  

Science Journals Connector (OSTI)

Landfill methane must be captured to reduce emissions of greenhouse gases; moreover it can be used as an alternative energy source. However, despite the widespread use of landfill gas (LFG) collection systems for...

Yoojin Jung; Paul Imhoff; Stefan Finsterle

2011-10-01T23:59:59.000Z

420

Mathematical Model for Heavy Oil–Water–Gas Stratified Flow in Horizontal Pipes  

Science Journals Connector (OSTI)

A one-dimensional, isothermal, transient model for the stratified flow of heavy oil, water and gas, in horizontal pipelines, is presented. The two-fluid mathematical model consists of mass, momentum and energy...

C. Centeno-Reyes; O. Cazarez-Candia

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Oil and Natural Gas Subsector Cybersecurity Capability Maturity Model (February 2014)  

Energy.gov (U.S. Department of Energy (DOE))

The Oil and Natural Gas Subsector Cybersecurity Capability Maturity Model (ONG-C2M2) is a derivative of the Electricity Subsector Cybersecurity Capability Maturity Model (ES-C2M2) Version 1.1.

422

Liquefied Natural Gas (LNG) Vapor Dispersion Modeling with Computational Fluid Dynamics Codes  

E-Print Network (OSTI)

Federal regulation 49 CFR 193 and standard NFPA 59A require the use of validated consequence models to determine the vapor cloud dispersion exclusion zones for accidental liquefied natural gas (LNG) releases. For modeling purposes, the physical...

Qi, Ruifeng

2012-10-19T23:59:59.000Z

423

Application of the Stretched Exponential Production Decline Model to Forecast Production in Shale Gas Reservoirs  

E-Print Network (OSTI)

Production forecasting in shale (ultra-low permeability) gas reservoirs is of great interest due to the advent of multi-stage fracturing and horizontal drilling. The well renowned production forecasting model, Arps? Hyperbolic Decline Model...

Statton, James Cody

2012-07-16T23:59:59.000Z

424

Interacting entropy-corrected agegraphic Chaplygin gas model of dark energy  

E-Print Network (OSTI)

In this work, we consider the interacting agegraphic dark energy models with entropy correction terms due to loop quantum gravity. We study the correspondence between the Chaplygin gas energy density with the interacting entropy-corrected agegraphic dark energy models in non-flat FRW universe. We reconstruct the potentials and the dynamics of the interacting entropy-corrected agegraphic scalar field models. This model is also extended to the interacting entropy-corrected agegraphic generalized Chaplygin gas dark energy.

M. Malekjani; A. Khodam-Mohammadi

2010-04-07T23:59:59.000Z

425

Kinetic Model of Gas Bubble Dissolution in Groundwater and Its  

E-Print Network (OSTI)

that rely on the actual dissolved gas content of gases such as oxygen or nitrogen. To describe the bubble of this excess gas is controlled by the solubility and the molecular diffusivity of the gases considered to water in the pore space. In the case of noble gases in a through-flow system, solubility differences

Aeschbach-Hertig, Werner

426

Macroscopic transport models for rarefied gas flows: a brief review  

Science Journals Connector (OSTI)

......which has a non-negative production. For space reasons...considered to describe the gas on the macroscopic level...description of rarefied gas flows with Knudsen numbers...fraction of the numerical cost of microscopic solvers...available only for monatomic gases. Since most gases of......

Henning Struchtrup; Peyman Taheri

2011-10-01T23:59:59.000Z

427

Interacting generalized Chaplygin gas model in non-flat universe  

E-Print Network (OSTI)

We employ the generalized Chaplygin gas of interacting dark energy to obtain the equation of state for the generalized Chaplygin gas energy density in non-flat universe. By choosing a negative value for $B$ we see that $w_{\\rm \\Lambda}^{eff}< -1$, that corresponds to a universe dominated by phantom dark energy.

M R Setare

2007-11-04T23:59:59.000Z

428

Estimating Policy-Driven Greenhouse Gas Emissions Trajectories in California: The California Greenhouse Gas Inventory Spreadsheet (GHGIS) Model  

NLE Websites -- All DOE Office Websites (Extended Search)

Estimating Policy-Driven Greenhouse Estimating Policy-Driven Greenhouse Gas Emissions Trajectories in California: The California Greenhouse Gas Inventory Spreadsheet (GHGIS) Model Jeffery B. Greenblatt Energy Analysis and Environmental Impacts Department Environmental Energy Technologies Division Lawrence Berkeley National Laboratory Berkeley, CA 94720 November 2013 This work was supported by the Research Division, California Air Resources Board under ARB Agreement No. 12-329. LBNL-6451E DISCLAIMER This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor The Regents of the University of California, nor any of

429

Software-as-a-Service Optimised Scheduling of a Solar-Assisted HVAC System with Thermal Storage  

E-Print Network (OSTI)

1980, but its thermal solar and storage systems received achiller. A 30 m heat storage tank solar decouples heatfacility with thermal storage and solar- assisted HVAC for

Mammoli, Andrea

2014-01-01T23:59:59.000Z

430

A plug and play framework for an HVAC air handling unit and temperature sensor auto recognition technique.  

E-Print Network (OSTI)

??A plug and play framework for an HVAC air handling unit control system is proposed in this study. This is the foundation and the first… (more)

Zhou, Xiaohui

2010-01-01T23:59:59.000Z

431

Optimized Fan Control In Variable Air Volume HVAC Systems Using Static Pressure Resets: Strategy Selection and Savings Analysis.  

E-Print Network (OSTI)

??The potential of static pressure reset (SPR) control to save fan energy in variable air volume HVAC systems has been well documented. Current research has… (more)

Kimla, John

2010-01-01T23:59:59.000Z

432

MODEL FOR DETERMINING THE EFFECTIVE THERMAL CONDUCTIVITY OF PARTICLE BEDS WITH HIGH SOLID-TO-GAS THERMAL  

E-Print Network (OSTI)

MODEL FOR DETERMINING THE EFFECTIVE THERMAL CONDUCTIVITY OF PARTICLE BEDS WITH HIGH SOLID-TO-GAS- to-gas conductivity ratio (such as Be and He). The model has the capability of accounting with high solid-to-gas thermal conductivity ratios. This paper summarizes this modeling effort. Model

Abdou, Mohamed

433

A gas kick model for the personal computer  

E-Print Network (OSTI)

penetration on the flow 21 rate from a gas zone 22 Fig. 8 - Increase in the gas inflow rate as a kick progzesses 24 Fig. 9 - Slug approximation of gas mud mixing Fig. 10 - Pressures at the top of the drill string during 26 Stage 1 27 Fig. 11.... Drilling balanced or slightly underbalanced increases the penetration rate of the drill bit. With these conditions there is little room for fluctuations in the pressure however, and a slight change in circulating hydraulics may be enough to bring on a...

Miller, Clayton Lowell

2012-06-07T23:59:59.000Z

434

Simulator for unconventional gas resources multi-dimensional model SUGAR-MD. Volume I. Reservoir model analysis and validation  

SciTech Connect

The Department of Energy, Morgantown Energy Technology Center, has been supporting the development of flow models for Devonian shale gas reservoirs. The broad objectives of this modeling program are: (1) To develop and validate a mathematical model which describes gas flow through Devonian shales. (2) To determine the sensitive parameters that affect deliverability and recovery of gas from Devonian shales. (3) To recommend laboratory and field measurements for determination of those parameters critical to the productivity and timely recovery of gas from the Devonian shales. (4) To analyze pressure and rate transient data from observation and production gas wells to determine reservoir parameters and well performance. (5) To study and determine the overall performance of Devonian shale reservoirs in terms of well stimulation, well spacing, and resource recovery as a function of gross reservoir properties such as anisotropy, porosity and thickness variations, and boundary effects. The flow equations that are the mathematical basis of the two-dimensional model are presented. It is assumed that gas transport to producing wells in Devonian shale reservoirs occurs through a natural fracture system into which matrix blocks of contrasting physical properties deliver contained gas. That is, the matrix acts as a uniformly distributed gas source in a fracture medium. Gas desorption from pore walls is treated as a uniformly distributed source within the matrix blocks. 24 references.

Not Available

1982-01-01T23:59:59.000Z

435

Derivation of a Langmuir type of model to describe the intrinsic growth rate of gas hydrates during crystallization from gas mixtures  

E-Print Network (OSTI)

Derivation of a Langmuir type of model to describe the intrinsic growth rate of gas hydrates during crystallization from gas mixtures Jean-Michel Herri* and Matthias Kwaterski Ecole Nationale Supérieure des Mines de Saint-Etienne, 158 Cours Fauriel, 42023 Saint- Etienne, France Abstract Gas Hydrates

Paris-Sud XI, Université de

436

Modelling Gas And Dust Release From Comet Hale–Bopp  

Science Journals Connector (OSTI)

Numerical simulations of the evolving activity of comet Hale-Bopp are presented, assuming a porous, ... km in radius, made of dust and gas-laden amorphous ice. The main effects included ... crystallization of amo...

D. Prialnik

437

Gas Network Optimization: A comparison of Piecewise Linear Models  

E-Print Network (OSTI)

aXM, Compañía de Expertos en Mercados, Colombian Power System Operator, Medellín, ...... rate of heat transfer per unit time and unit mass of the gas [W/kg].

2014-06-22T23:59:59.000Z

438

New model adds precision to gas-lift design  

SciTech Connect

Conoco Inc.'s new analytical technique for lift-gas allocation identifies, in one-pass, injection rates and the achievable mandrel location for injection. Current gas-lift allocation techniques do not determine production rates for discrete mandrel locations. Allocation rates for particular wells are made on the basis of a fixed differential pressure. When actual mandrel locations are superimposed on these solutions, gas often must be reallocated. The advantages of the new technique include: determining the transfer capability of the gas-lift valve in each mandrel; finding valve pressure drop as a function of injection gas rate; obtaining a more realistic response curve. Another potential benefit is that the response curve can be adjusted to reflect the water cut and/or multizone completion effects at different injection depths. Because the node is at the mandrel, the inflow performance relationship (IPR) at that depth can easily be adjusted to include such effects. The paper describes gas-lift applications; response curves; injection depth; field-wide curves; the mandrel curve; and valve design.

Kendrick, R.A. (Hampton Resources Inc., Houston, TX (United States)); Woodyard, A.H.; Hall, J.W. (Conoco Inc., Houston, TX (United States))

1993-05-03T23:59:59.000Z

439

Investigations of swirl flames in a gas turbine model combustor  

SciTech Connect

A gas turbine model combustor for swirling CH{sub 4}/air diffusion flames at atmospheric pressure with good optical access for detailed laser measurements is discussed. Three flames with thermal powers between 7.6 and 34.9 kW and overall equivalence ratios between 0.55 and 0.75 were investigated. These behave differently with respect to combustion instabilities: Flame A burned stably, flame B exhibited pronounced thermoacoustic oscillations, and flame C, operated near the lean extinction limit, was subject to sudden liftoff with partial extinction and reanchoring. One aim of the studies was a detailed experimental characterization of flame behavior to better understand the underlying physical and chemical processes leading to instabilities. The second goal of the work was the establishment of a comprehensive database that can be used for validation and improvement of numerical combustion models. The flow field was measured by laser Doppler velocimetry, the flame structures were visualized by planar laser-induced fluorescence (PLIF) of OH and CH radicals, and the major species concentrations, temperature, and mixture fraction were determined by laser Raman scattering. The flow fields of the three flames were quite similar, with high velocities in the region of the injected gases, a pronounced inner recirculation zone, and an outer recirculation zone with low velocities. The flames were not attached to the fuel nozzle and thus were partially premixed before ignition. The near field of the flames was characterized by fast mixing and considerable finite-rate chemistry effects. CH PLIF images revealed that the reaction zones were thin (=<0.5 mm) and strongly corrugated and that the flame zones were short (h=<50 mm). Despite the similar flow fields of the three flames, the oscillating flame B was flatter and opened more widely than the others. In the current article, the flow field, structures, and mean and rms values of the temperature, mixture fraction, and species concentrations are discussed. Turbulence intensities, mixing, heat release, and reaction progress are addressed. In a second article, the turbulence-chemistry interactions in the three flames are treated.

Weigand, P.; Meier, W.; Duan, X.R.; Stricker, W.; Aigner, M. [Institut fuer Verbrennungstechnik, Deutsches Zentrum fuer Luft- und Raumfahrt (DLR), Pfaffenwaldring 38, D-70569 Stuttgart (Germany)

2006-01-01T23:59:59.000Z

440

The production characteristics of a solution gas-drive reservoir as measured on a centrifugal model  

E-Print Network (OSTI)

of Texas in partial fulfillment oi' the requirements for the degree of MASTER OF SCIENCE August, 1955 Major Subject: Petroleum Engineering THE PRODUCTION CHARACTERISTICS OF A SOLUTION GAS-DRIVE RESERVOIR AS MEASURED ON A CENTRIFUGAL MODEL A Thesis... gas drive reservoir per- formancee at high pressures. The construe tj onal and operational details for the model are given, The results of forty model flow tests are given in which magnitudes of the we11 densi4y, production rate, fluid viscosity...

Goodwin, Robert Jennings

2012-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Models, Simulators, and Data-driven Resources for Oil and Natural Gas Research  

DOE Data Explorer (OSTI)

NETL provides a number of analytical tools to assist in conducting oil and natural gas research. Software, developed under various DOE/NETL projects, includes numerical simulators, analytical models, databases, and documentation.[copied from http://www.netl.doe.gov/technologies/oil-gas/Software/Software_main.html] Links lead users to methane hydrates models, preedictive models, simulators, databases, and other software tools or resources.

442

A simple model of gas flow in a porous powder compact  

SciTech Connect

This report describes a simple model for ideal gas flow from a vessel through a bed of porous material into another vessel. It assumes constant temperature and uniform porosity. Transport is treated as a combination of viscous and molecular flow, with no inertial contribution (low Reynolds number). This model can be used to fit data to obtain permeability values, determine flow rates, understand the relative contributions of viscous and molecular flow, and verify volume calibrations. It draws upon the Dusty Gas Model and other detailed studies of gas flow through porous media.

Shugard, Andrew D.; Robinson, David B.

2014-04-01T23:59:59.000Z

443

Evaluation of flow capture techniques for measuring HVAC grilleairflows  

SciTech Connect

This paper discusses the accuracy of commercially available flow hoods for residential applications. Results of laboratory and field tests indicate these hoods can be inadequate to measure airflows in residential systems, and there can be large measurement discrepancies between different flow hoods. The errors are due to poor calibrations, sensitivity of the hoods to grille airflow non-uniformities, and flow changes from added flow resistance. It is possible to obtain reasonable results using some flow hoods if the field tests are carefully done, the grilles are appropriate, and grille location does not restrict flow hood placement. We also evaluated several simple flow capture techniques for measuring grille airflows that could be adopted by the HVAC industry and homeowners as simple diagnostics. These simple techniques can be as accurate as commercially available devices. Our test results also show that current calibration procedures for flow hoods do not account for field application problems. As a result, agencies such as ASHRAE or ASTM need to develop a new standard for flow hood calibration, along with a new measurement standard to address field use of flow capture techniques.

Walker, Iain S.; Wray, Craig P.

2002-11-01T23:59:59.000Z

444

Outdoor airflow into HVAC systems: An evaluation of measurement technologies  

SciTech Connect

During the last few years, new technologies have been introduced for measuring the flow rates of outdoor air (OA) into HVAC systems; however, an evaluation of these measurement technologies has not previously been published. This document describes a test system and protocols developed for controlled evaluation of these measurement technologies. The results of tests of three measurement technologies are also summarized. The test system and protocol were judged practical and very useful. The test results indicate that one measurement technology can measure OA flow rates with errors of 20% or less without a field-based calibration, as long as the OA velocities are sufficient to provide an accurately measurable pressure signal. The test results for a second measurement technology are similar; however, a difficult field-based calibration relating the OA flow rate with the pressure signal would be required to reduce errors below approximately 30%. The errors in OA flow rates measured with the third measurement technology, that uses six electronic airspeed sensors downstream of the OA inlet louver, exceeded 100%; however, these errors could be substantially reduced through a difficult field based calibration. The effects of wind on the accuracy of these measurement technologies still needs to be evaluated.

Fisk, William J.; Faulkner, David; Sullivan, Douglas P.; Delp, Woody

2003-09-01T23:59:59.000Z

445

Compression effects on pressure loss in flexible HVAC ducts  

SciTech Connect

A study was conducted to evaluate the effect of compression on pressure drop in flexible, spiral wire helix core ducts used in residential and light commercial applications. Ducts of 6 inches, 8 inches and 10 inches (150, 200 and 250 mm) nominal diameters were tested under different compression configurations following ASHRAE Standard 120-1999--Methods of Testing to Determine Flow Resistance of HVAC Air Ducts and Fittings. The results showed that the available published references tend to underestimate the effects of compression. The study demonstrated that moderate compression in flexible ducts, typical of that often seen in field installations, could increase the pressure drop by a factor of four, while further compression could increase the pressure drop by factors close to ten. The results proved that the pressure drop correction factor for compressed ducts cannot be independent of the duct size, as suggested by ASHRAE Fundamentals, and therefore a new relationship was developed for better quantification of the pressure drop in flexible ducts. This study also suggests potential improvements to ASHRAE Standard 120-1999 and provides new data for duct design.

Abushakra, Bass; Walker, Iain S.; Sherman, Max H.

2002-07-01T23:59:59.000Z

446

Uncertainty and sensitivity analysis of fission gas behavior in engineering-scale fuel modeling  

SciTech Connect

The role of uncertainties in fission gas behavior calculations as part of engineering-scale nuclear fuel modeling is investigated using the BISON fuel performance code and a recently implemented physics-based model for the coupled fission gas release and swelling. Through the integration of BISON with the DAKOTA software, a sensitivity analysis of the results to selected model parameters is carried out based on UO2 single-pellet simulations covering different power regimes. The parameters are varied within ranges representative of the relative uncertainties and consistent with the information from the open literature. The study leads to an initial quantitative assessment of the uncertainty in fission gas behavior modeling with the parameter characterization presently available. Also, the relative importance of the single parameters is evaluated. Moreover, a sensitivity analysis is carried out based on simulations of a fuel rod irradiation experiment, pointing out a significant impact of the considered uncertainties on the calculated fission gas release and cladding diametral strain. The results of the study indicate that the commonly accepted deviation between calculated and measured fission gas release by a factor of 2 approximately corresponds to the inherent modeling uncertainty at high fission gas release. Nevertheless, higher deviations may be expected for values around 10% and lower. Implications are discussed in terms of directions of research for the improved modeling of fission gas behavior for engineering purposes.

G. Pastore; L.P. Swiler; J.D. Hales; S.R. Novascone; D.M. Perez; B.W. Spencer; L. Luzzi; P. Van Uffelen; R.L. Williamson

2014-10-01T23:59:59.000Z

447

Modeling impacts of carbon sequestration on net greenhouse gas emissions from agricultural soils in China  

E-Print Network (OSTI)

Modeling impacts of carbon sequestration on net greenhouse gas emissions from agricultural soils impacts of carbon sequestration on net greenhouse gas emissions from agricultural soils in China, Global Biogeochem. Cycles, 23, GB1007, doi:10.1029/2008GB003180. 1. Introduction [2] Carbon (C) sequestration has

448

Modeling of Multilayer Composite Fabrics for Gas Turbine Engine Containment Systems  

E-Print Network (OSTI)

Modeling of Multilayer Composite Fabrics for Gas Turbine Engine Containment Systems J. Sharda1 ; C of multilayer composite fabrics used in a gas turbine engine containment system is developed. Specifically: Tensile strength; Stress analysis; Stress strain relations; Fabrics; Composite materials; Finite element

Mobasher, Barzin

449

Interacting polytropic gas model of phantom dark energy in non-flat universe  

E-Print Network (OSTI)

By introducing the polytropic gas model of interacting dark energy, we obtain the equation of state for the polytropic gas energy density in a non-flat universe. We show that for even polytropic index by choosing $K>Ba^{\\frac{3}{n}}$, one can obtain $\\omega^{\\rm eff}_{\\Lambda}<-1$, which corresponds to a universe dominated by phantom dark energy.

K. Karami; S. Ghaffari; J. Fehri

2009-11-25T23:59:59.000Z

450

Computer Modeling VRF Heat Pumps in Commercial Buildings using EnergyPlus  

SciTech Connect

Variable Refrigerant Flow (VRF) heat pumps are increasingly used in commercial buildings in the United States. Monitored energy use of field installations have shown, in some cases, savings exceeding 30% compared to conventional heating, ventilating, and air-conditioning (HVAC) systems. A simulation study was conducted to identify the installation or operational characteristics that lead to energy savings for VRF systems. The study used the Department of Energy EnergyPlus? building simulation software and four reference building models. Computer simulations were performed in eight U.S. climate zones. The baseline reference HVAC system incorporated packaged single-zone direct-expansion cooling with gas heating (PSZ-AC) or variable-air-volume systems (VAV with reheat). An alternate baseline HVAC system using a heat pump (PSZ-HP) was included for some buildings to directly compare gas and electric heating results. These baseline systems were compared to a VRF heat pump model to identify differences in energy use. VRF systems combine multiple indoor units with one or more outdoor unit(s). These systems move refrigerant between the outdoor and indoor units which eliminates the need for duct work in most cases. Since many applications install duct work in unconditioned spaces, this leads to installation differences between VRF systems and conventional HVAC systems. To characterize installation differences, a duct heat gain model was included to identify the energy impacts of installing ducts in unconditioned spaces. The configuration of variable refrigerant flow heat pumps will ultimately eliminate or significantly reduce energy use due to duct heat transfer. Fan energy is also studied to identify savings associated with non-ducted VRF terminal units. VRF systems incorporate a variable-speed compressor which may lead to operational differences compared to single-speed compression systems. To characterize operational differences, the computer model performance curves used to simulate cooling operation are also evaluated. The information in this paper is intended to provide a relative difference in system energy use and compare various installation practices that can impact performance. Comparative results of VRF versus conventional HVAC systems include energy use differences due to duct location, differences in fan energy when ducts are eliminated, and differences associated with electric versus fossil fuel type heating systems.

Raustad, Richard

2013-06-01T23:59:59.000Z

451

Computational Science Technical Note CSTN-147 Visual Simulation of a Multi-Species Coloured Lattice Gas Model  

E-Print Network (OSTI)

Lattice Gas Model T. S. Lyes and M. G. B. Johnson and K. A. Hawick 2012 Understanding complex fluid flow describe how a coloured lattice gas model was developed and run on a graphical processing unit using NVIDIA Gas Model}, booktitle = {Proc. Int. Conf. on Scientific Computing (CSC'12)}, year = {2012}, pages

Hawick, Ken

452

Solution of lattice gas models in the generalized ensemble on the Bethe lattice Emilia La Nave,1,2  

E-Print Network (OSTI)

Solution of lattice gas models in the generalized ensemble on the Bethe lattice Emilia La Nave,1 for a lattice gas Potts model defined in the generalized ensemble which was previously studied in elucidating, such as geometric aspects via percolation. In this paper, we consider a lattice gas Potts model stud- ied previously

Sciortino, Francesco

453

Evaluation of HVAC filters as a sampling mechanism for indoor microbial communities  

Science Journals Connector (OSTI)

HVAC filters are in place for extended periods of time and can serve as integrated air samplers. This paper presents a comparison of bacterial and fungal concentrations and communities in HVAC filter dust and other sampling locations in occupied residences and in the unoccupied \\{UTest\\} House. A DNA-based, culture-independent approach was utilized to characterize the microbial communities. Microbial concentrations and communities in HVAC filter dust samples were not statistically different from those in high surface dust samples in occupied homes. Despite the general similarity in the communities, Proteobacteria were present in greater proportion in HVAC filter dust samples than in surface dust samples suggesting the air origin of this phylum. Gram-positive bacteria were present in greater proportion in occupied residences than in an unoccupied test house, confirming the potential association of this group with occupants. HVAC filter microbial communities were not different from those present in a composited month-long indoor air sample providing preliminary evidence that filters could be a viable option for long-term investigation of airborne biological contaminants.

Federico Noris; Jeffrey A. Siegel; Kerry A. Kinney

2011-01-01T23:59:59.000Z

454

Interacting entropy-corrected holographic Chaplygin gas model  

E-Print Network (OSTI)

Holographic dark energy (HDE), presents a dynamical view of dark energy which is consistent with the observational data and has a solid theoretical background. Its definition follows from the entropy-area relation $S(A)$, where $S$ and $A$ are entropy and area respectively. In the framework of loop quantum gravity, a modified definition of HDE called "entropy-corrected holographic dark energy" (ECHDE) has been proposed recently to explain dark energy with the help of quantum corrections to the entropy-area relation. Using this new definition, we establish a correspondence between modified variable Chaplygin gas, new modified Chaplygin gas and the viscous generalized Chaplygin gas with the entropy corrected holographic dark energy and reconstruct the corresponding scalar potentials which describe the dynamics of the scalar field.

M. Umar Farooq; Muneer A. Rashid; Mubasher Jamil

2010-03-17T23:59:59.000Z

455

CFD modeling of a gas turbine combustor from compressor exit to turbine inlet  

SciTech Connect

Gas turbine combustor CFD modeling has become an important combustor design tool in the past few years, but CFD models are generally limited to the flow field inside the combustor liner at the diffuser/combustor annulus region. Although strongly coupled in reality, the two regions have rarely been coupled in CFD modeling. A CFD calculation for a full model combustor from compressor diffuser exit to turbine inlet is described. The coupled model accomplishes the following two main objectives: (1) implicit description of flow splits and flow conditions for openings into the combustor liner, and (2) prediction of liner wall temperatures. Conjugate heat transfer with nonluminous gas radiation (appropriate for lean, low emission combustors) is utilized to predict wall temperatures compared to the conventional approach of predicting only near wall gas temperatures. Remaining difficult issues such as generating the grid, modeling swirler vane passages, and modeling effusion cooling are also discussed.

Crocker, D.S.; Nickolaus, D.; Smith, C.E. [CFD Research Corp., Huntsville, AL (United States)

1999-01-01T23:59:59.000Z

456

High-Speed Internet Access via HVAC Ducts: A New Approach Daniel D. Stancil, Ozan K. Tonguz, Ariton Xhafa, Ahmet Cepni, and Pavel Nikitin  

E-Print Network (OSTI)

High-Speed Internet Access via HVAC Ducts: A New Approach Daniel D. Stancil, Ozan K. Tonguz, Ariton conditioning (HVAC) ducts for indoor wireless transmission systems and networks. Mea- surements and system to 100 Mbps should be possible, when HVAC system is used in con- junction with OFDM technology. Keywords

Stancil, Daniel D.

457

This paper has been downloaded from the Building and Environmental Thermal Systems Research Group at Oklahoma State University (www.hvac.okstate.edu)  

E-Print Network (OSTI)

at Oklahoma State University (www.hvac.okstate.edu) The correct citation for the paper is: Rees, S.J., J cooling loads is of critical concern to designers of HVAC systems. The work reported here has been carried of the HVAC industry worldwide would be improved if common methods of performing key design calculations were

Ghajar, Afshin J.

458

Cooperative Control of Air Flow for HVAC Systems Shuai Liu1,2, Yushen Long1, Lihua Xie1 and Alexandre M. Bayen3  

E-Print Network (OSTI)

Cooperative Control of Air Flow for HVAC Systems Shuai Liu1,2, Yushen Long1, Lihua Xie1 for building heating, ven- tilation and air-conditioning (HVAC) systems. The strategy consists in two level and the HVAC system parameters. I. INTRODUCTION In recent years, energy saving and environment protection have

459

Logue and Singer, HVAC&R, 20(2): 264-275, 2014. Energy Impacts of Effective Residential Range Hood Use, LBNL-6683E Page 1  

E-Print Network (OSTI)

Logue and Singer, HVAC&R, 20(2): 264-275, 2014. Energy Impacts of Effective Residential Range Hood and Singer, HVAC&R, 20(2): 264-275, 2014. Energy Impacts of Effective Residential Range Hood Use, LBNL-6683E Laboratory is an equal opportunity employer. #12;Logue and Singer, HVAC&R, 20(2): 264-275, 2014. Energy

460

An integrated performance model for high temperature gas cooled reactor coated particle fuel  

E-Print Network (OSTI)

The performance of coated fuel particles is essential for the development and deployment of High Temperature Gas Reactor (HTGR) systems for future power generation. Fuel performance modeling is indispensable for understanding ...

Wang, Jing, 1976-

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

A three–dimensional lattice–gas model for amphiphilic fluid dynamics  

Science Journals Connector (OSTI)

...it is implemented using high-performance computing and visualization techniques...mesoscale modelling|high-performance computing|lattice gas|amphiphilic...is imple- mented using high-performance computing and visualization techniques...

2000-01-01T23:59:59.000Z

462

Modeling Population Exposures to Pollutants Emitted from Natural Gas Cooking Burners  

E-Print Network (OSTI)

, CA 94720 2 Stanford University Palo Alto, CA June 2011, Berkeley, CA 94720 2 Stanford University, Palo Alto, CA * Corresponding email: ablobscheid@lbl.gov SUMMARYiPage | i Modeling Population Exposures to Pollutants Emitted from Natural Gas Cooking

463

Modeling and Measuring Greenhouse Gas Reduction from Low Carbon Airport Access Modes  

E-Print Network (OSTI)

domestic  greenhouse gas (GHG) emissions in 2003.  Within proportion of aviation system GHG emissions; due to their for aviation  system GHG reduction.  Discrete choice models 

Smirti, Megan

2008-01-01T23:59:59.000Z

464

Modeling the final phase of landfill gas generation from long-term observations  

Science Journals Connector (OSTI)

For waste management, methane emissions from landfills and their effect on climate change are of serious concern. Current models for biogas generation that focus on the economic use of the landfill gas are usuall...

Johannes Tintner; Manfred Kühleitner; Erwin Binner; Norbert Brunner…

2012-06-01T23:59:59.000Z

465

Modified landfill gas generation rate model of first-order kinetics and two-stage reaction  

Science Journals Connector (OSTI)

This investigation was carried out to establish a new domestic landfill gas (LFG) generation rate model that takes...L 0), the reaction rate constant in the first stage (K 1), and ...

Jiajun Chen; Hao Wang…

2009-09-01T23:59:59.000Z

466

Modeling and simulation of landfill gas production from pretreated MSW landfill simulator  

Science Journals Connector (OSTI)

The cumulative landfill gas (LFG) production and its rate ... simulated for pretreated municipal solid waste (MSW) landfill using four models namely first order exponential ... . Considering the behavior of the p...

Rasool Bux Mahar; Abdul Razaque Sahito…

2014-04-01T23:59:59.000Z

467

Statefinder diagnostic and $w-w^{\\prime}$ analysis for interacting polytropic gas dark energy model  

E-Print Network (OSTI)

The interacting polytropic gas dark energy model is investigated from the viewpoint of statefinder diagnostic tool and $w-w^{\\prime}$ analysis. The dependency of the statefinder parameters on the parameter of the model as well as the interaction parameter between dark matter and dark energy is calculated. We show that different values of the parameters of model and different values of interaction parameter result different evolutionary trajectories in $s-r$ and $w-w^{\\prime}$ planes. The polytropic gas model of dark energy mimics the standard $\\Lambda$CDM model at the early time.

M. Malekjani; A. Khodam-Mohammadi

2012-01-03T23:59:59.000Z

468

Graduate Opportunities in Atmospheric Modeling to Understand Greenhouse Gas Emissions  

E-Print Network (OSTI)

and energy infrastructure. The graduate projects, fully funded by the National Oceanic and Atmospheric greenhouse gas emissions. Samples of guiding questions as part of the projects include: � What can explain; (3) demonstrated computer skills (e.g., Linux, R, Matlab, Fortran, GIS); (4) excellent oral

Lin, John Chun-Han

469

Polyakov loop, Hadron Resonance Gas Model and Thermodynamics of QCD  

E-Print Network (OSTI)

We summarize recent results on the hadron resonance gas description of QCD. In particular, we apply this approach to describe the equation of state and the vacuum expectation value of the Polyakov loop in several representations. Ambiguities related to exactly which states should be included are discussed.

E. Megias; E. Ruiz Arriola; L. L. Salcedo

2013-10-11T23:59:59.000Z

470

A placement model for matrix acidizing of vertically extensive, multilayer gas reservoirs  

E-Print Network (OSTI)

A PLACEMENT MODEL FOR MATRIX ACIDIZING OF VERTICALLY EXTENSIVE, MULTILAYER GAS RESERVOIRS A Thesis by MANABU NOZAKI Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements... for the degree of MASTER OF SCIENCE August 2008 Major Subject: Petroleum Engineering A PLACEMENT MODEL FOR MATRIX ACIDIZING OF VERTICALLY EXTENSIVE, MULTILAYER GAS RESERVOIRS A Thesis by MANABU NOZAKI Submitted to the Office...

Nozaki, Manabu

2008-10-10T23:59:59.000Z

471

Caloric Curves for small systems in the Nuclear Lattice Gas Model  

E-Print Network (OSTI)

For pedagogical reasons we compute the caloric curve for 11 particles in a $3^3$ lattice. Monte-Carlo simulation can be avoided and exact results are obtained. There is no back-bending in the caloric curve and negative specific heat does not appear. We point out that the introduction of kinetic energy in the nuclear Lattice Gas Model modifies the results of the standard Lattice Gas Model in a profound way.

C. B. Das; S. Das Gupta

2000-09-27T23:59:59.000Z

472

Applied modelling for bio and lean gas fired micro gas turbines  

Science Journals Connector (OSTI)

This contribution presents the outcome of applied Computational Fluid Dynamics for analysis of combustion technologies to find an efficient firing mode for use of bio and low calorific gaseous fuels in micro gas turbine combustors. The combustion technologies considered are based on the new concepts of Flameless Oxidation and Continued Staged Air. To optimise these concepts to burn low calorific gaseous fuels manifold numerical simulations were carried out using the CFD code FLUENT. The results achieved showed the influence of the fuel compositions on the flow behaviour inside the combustion chamber, reaction zone, flame structure and pollutant emissions.

A. Al-Halbouni; A. Giese; M. Flamme; K. Goerner

2006-01-01T23:59:59.000Z

473

Development of a Model Specification for Performance Monitoring Systems for Commercial Buildings  

E-Print Network (OSTI)

OA Damper Fraction 7. Whole Bldg Electric EUI; Whole bldgHVAC electric only EUI; Whole BldgNatural Gas EUI , Whole Bldg Water EUI vs. Avg. Daily OA

2008-01-01T23:59:59.000Z

474

Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions for  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Critical Question #4: What are the Best Off-the-Shelf HVAC Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions for Low-Load, High-Performance Homes and Apartments? Critical Question #4: What are the Best Off-the-Shelf HVAC Solutions for Low-Load, High-Performance Homes and Apartments? What is currently in the market? What are the limitations of these systems? What are the desired specifications for these systems? What are the realistic space conditioning loads of these high-performance homes and apartments? cq4_forced_air_systems_walker.pdf cq4_simplified_space_cond_prahl.pdf cq4_ground_heat_exchanger_im.pdf More Documents & Publications Track C - Market-Driven Research Solutions Track B - Critical Guidance for Peak Performance Homes Energy Storage & Power Electronics 2008 Peer Review - Power Electronics

475

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

476

HVAC vs. Space Heaters: Which is More Efficient? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? HVAC vs. Space Heaters: Which is More Efficient? January 10, 2011 - 4:27pm Addthis Andrea Spikes Communicator at DOE's National Renewable Energy Laboratory I live in Colorado, and when it's cold it is very, very cold. Since I hate paying high heating bills, I typically have my thermostat set to a chilly 62°F. My husband and I have gotten used to this, and really like being able to use a warm comforter while the air stays cooler. There are some nights, however, that even this setting seems too high and the heater is running a lot more than I'd like it to. When it's below 0° overnight, or even sometimes during the day, we occasionally break out our oil-filled space heater when we're only using one room. That has me

477

Analytical model of the temperature dependent properties of microresonators immersed in a gas  

SciTech Connect

A comprehensive theoretical model of microresonators immersed in a viscous gas of varying temperature is presented and verified by experiments. Analytical expressions for both the temperature dependent resonant frequency and quality factor of the first flexural eigenmode were derived extending Sader's theory of viscous damping to small temperature variations. The model provides useful implications for the thermal stabilization of microresonators immersed in a gas as well as for the reduction in the influence of the temperature dependent gas properties on the resonant frequency. Finally, an analytical expression is deduced for the mass detection capability of a microresonator that undergoes temperature variations.

Ilin, E. A.; Kehrbusch, J.; Radzio, B.; Oesterschulze, E. [Physics and Technology of Nanostructures, Nano-Bio-Center, University of Kaiserslautern, Erwin-Schroedinger Strasse 46, 67663 Kaiserslautern (Germany)

2011-02-01T23:59:59.000Z

478

Special Section --Marine Controlled-Source Electromagnetic Methods A Bayesian model for gas saturation estimation  

E-Print Network (OSTI)

Special Section -- Marine Controlled-Source Electromagnetic Methods A Bayesian model for gas Vasco1 , Yoram Rubin2 , and Zhangshuan Hou2 ABSTRACT We develop a Bayesian model to jointly invert reservoir model. We consid- er the porosity and fluid saturation of each layer in the reservoir, the bulk

Chen, Jinsong

479

Selecting Building Predictive Control Based on Model Uncertainty  

E-Print Network (OSTI)

S. Pr´?vara et al. “Building Modeling as a Crucial Part forThe details of building thermal modeling and estimation ofModeling and Optimal Control Algorithm Design for HVAC Systems in Energy Efficient Buildings”.

Maasoumy, Mehdi

2014-01-01T23:59:59.000Z

480

Modeling the Belgian gas consumption W. Favoreel, P. Lemmerling, J. Suykens, B. De Moor, \\Lambda M. Crepel, P. Briol y  

E-Print Network (OSTI)

Modeling the Belgian gas consumption W. Favoreel, P. Lemmerling, J. Suykens, B. De Moor, \\Lambda M in particular to normalize the gas consumption with respect to temperature. Key Words: modeling, time series rate of the market and the normalization of the gas consumption with respect to temperature changes

Note: This page contains sample records for the topic "gas hvac modeling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Description of noble gas di usion in a polymer matrix by a hopping model Alexander K. Hartmann, Dieter W. Heermann  

E-Print Network (OSTI)

Description of noble gas di usion in a polymer matrix by a hopping model Alexander K. Hartmann 19 69120 Heidelberg, Germany (December 1, 1998) We present a new heuristic model which describes the dif- fusion of noble gas atoms inside a polymer matrix. The mo- tion of the gas atoms consists

Heermann, Dieter W.

482

Study on optimization model of energy collection efficiency and its power generation benefit evaluation of landfill gas  

Science Journals Connector (OSTI)

An optimization model for joint biogas energy collection efficiency that targets the prediction model for landfill gas output dynamics and the optimization model for gas well output has been established. The model was used to comprehensively analyze and evaluate the collection efficiency of a landfill gas well together with the long-term monitoring the gas output of the gas well within Chenjiachong Landfill. The collection efficiency increased by more than 50% than the original collection of landfill biogas and the power generation efficiency increased more than two times after the reservoir area of the landfill was optimized and regulated.

Xue Qiang

2013-01-01T23:59:59.000Z

483

Dark Energy - Dark Matter Unification: Generalized Chaplygin Gas Model  

E-Print Network (OSTI)

We review the main features of the generalized Chaplygin gas (GCG) proposal for unification of dark energy and dark matter and discuss how it admits an unique decomposition into dark energy and dark matter components once phantom-like dark energy is excluded. In the context of this approach we consider structure formation and show that unphysical oscillations or blow-up in the matter power spectrum are not present. Moreover, we demonstrate that the dominance of dark energy occurs about the time when energy density fluctuations start evolving away from the linear regime.

Orfeu Bertolami

2005-04-14T23:59:59.000Z

484

Artificial neural network models for predicting condition of offshore oil and gas pipelines  

Science Journals Connector (OSTI)

Abstract Pipelines daily transport and distribute huge amounts of oil and gas across the world. They are considered the safest method of transporting oil and gas because of their limited number of failures. However, pipelines are subject to deterioration and degradation. It is therefore important that pipelines be effectively monitored to optimize their operation and to reduce their failures to an acceptable safety limit. Numerous models have been developed recently to predict pipeline conditions. Nevertheless, most of these models have used corrosion features alone to assess the condition of pipelines. Hence, this paper presents the development of models that evaluate and predict the condition of offshore oil and gas pipelines based on several factors besides corrosion. The models were developed using artificial neural network (ANN) technique based on historical inspection data collected from three existing offshore oil and gas pipelines in Qatar. The models were able to successfully predict pipeline conditions with an average percent validity above 97% when applied to the validation data set. The models are expected to help pipeline operators to assess and predict the condition of existing oil and gas pipelines and hence prioritize the planning of their inspection and rehabilitation.

Mohammed S. El-Abbasy; Ahmed Senouci; Tarek Zayed; Farid Mirahadi; Laya Parvizsedghy

2014-01-01T23:59:59.000Z

485

A New Variable Modified Chaplygin Gas Model Interacting with Scalar Field  

E-Print Network (OSTI)

In this letter we present a new form of the well known Chaplygin gas model by introducing inhomogeneity in the EOS. This model explains $\\omega=-1$ crossing. Also we have given a graphical representation of the model using $\\{r,s\\}$ parameters. We have also considered an interaction of this model with the scalar field by introducing a phenomenological coupling function and have shown that the potential decays with time.

Writambhara Chakraborty; Ujjal Debnath

2010-06-11T23:59:59.000Z

486

Model Code for the Control of Residential HVAC Distribution System Leakage and HVAC-Induced Building Leakage  

E-Print Network (OSTI)

, Underwriters Laboratories, Inc., the Air Conditioning Contractors Of America, the Thermal Insulation Manufacturers Association, the National Fire Protection Association, and the Gypsum Association....

Wemhoff, P.

1990-01-01T23:59:59.000Z

487

MELTING OF GLASS BATCH: MODEL FOR MULTIPLE OVERLAPPING GAS-EVOLVING REACTIONS  

SciTech Connect

In this study, we present a model for the kinetics of multiple overlapping reactions. Mathematical representation of the kinetics of gas-evolving reactions is crucial for the modeling of the feed-to-glass conversion in a waste-glass melter. The model simulates multiple gas-evolving reactions that occur during heating of a high-alumina high-level waste melter feed. To obtain satisfactory kinetic parameters, we employed Kissinger's method combined with least-squares analysis. The power-law kinetics with variable reaction order sufficed for obtaining excellent agreement with measured thermogravimetric analysis data.

Pokorny, Richard; Pierce, David A.; Hrma, Pavel R.

2012-08-10T23:59:59.000Z

488

Hot-gas cleanup system model development. Volume I. Final report  

SciTech Connect

This two-volume report summarizes the state of the art in performance modeling of advanced high-temperature, high-pressure (HTHP) gas cleanup devices. Volume I contains the culmination of the research effort carried over the past 12 months and is a summary of research achievements. Volume II is the user's manual for the computer programs developed under the present research project. In this volume, Section 2 presents background information on pressurized, fluidized-bed combustion concepts, a description of the role of the advanced gas cleanup systems, and a list of advanced gas cleanup systems that are currently in development under DOE sponsorship. Section 3 describes the methodology for the software architecture that forms the basis of the well-disciplined and structured computer programs developed under the present project. Section 4 reviews the fundamental theories that are important in analyzing the cleanup performance of HTHP gas filters. Section 5 discusses the effect of alkali agents in HTHP gas cleanup. Section 6 evaluates the advanced HTHP gas cleanup models based on their mathematical integrity, availability of supporting data, and the likelihood of commercialization. As a result of the evaluation procedure detailed in Section 6, five performance models were chosen to be incorporated into the overall system simulation code, ASPEN. These five models (the electrocyclone, ceramic bag filter, moving granular bed filter, electrostatic granular bed filter, and electrostatic precipitator) are described in Section 7. The method of cost projection for these five models is discussed in Section 8. The supporting data and validation of the computer codes are presented in Section 9, and finally the conclusions and recommendations for the HTHP gas cleanup system model development are given in Section 10. 72 references, 19 figures, 25 tables.

Ushimaru, K.; Bennett, A.; Bekowies, P.J.

1982-11-01T23:59:59.000Z

489

An artificial intelligence approach to model-based gas lift troubleshooting  

E-Print Network (OSTI)

. Gas lift injection pressure is too high, I have not seen this pressure in the system before. . . . . something is wrong! Gas lift injection pressure is greater than the value given by the computerized gas lift design model C 3 O O 0 0 O... porous medium is proportional to the pressure or hydraulic gradient and to the cross-sectional area normal to the direction of flow and inversely proportional to the viscosity of the fluid. CO C 3 FLUID THROUGH POROUS MEDIUM 0 0 r)( r Fig. 2. 3...

Ortiz-Volcan, Jose Luis

1990-01-01T23:59:59.000Z

490

ARTICLE IN PRESS Modeling hydrogen sulfide emissions across the gas liquid interface  

E-Print Network (OSTI)

production methods in the US have led to the emergence of large- scale commeARTICLE IN PRESS Modeling hydrogen sulfide emissions across the gas­ liquid interface-film theory Hydrogen sulfide Process-based model Lagoon flux Mass transfer a b s t r a c t Hydrogen sulfide (H

Aneja, Viney P.

491

Joint Modelling of Gas and Electricity spot prices N. Frikha1 , V. Lemaire2  

E-Print Network (OSTI)

Joint Modelling of Gas and Electricity spot prices N. Frikha1 , V. Lemaire2 October 13, 2010 for developing a risk management framework as well as pricing of options. Many derivatives on both electricity and electricity prices is a relevant issue. Numerous diffusion-type and econometric models have been proposed

Boyer, Edmond

492

Joint Modelling of Gas and Electricity spot prices N. Frikha1 , V. Lemaire2  

E-Print Network (OSTI)

Joint Modelling of Gas and Electricity spot prices N. Frikha1 , V. Lemaire2 October 9, 2009 for developing a risk management framework as well as pricing of options. Many derivatives on both electricity and electricity prices is a relevant issue. Numerous diffusion-type and econometric models have been proposed

493

A single model of traversable wormholes supported by generalized phantom energy or Chaplygin gas  

E-Print Network (OSTI)

This paper discusses a new variable equation of state parameter leading to exact solutions of the Einstein field equations describing traversable wormholes. In addition to generalizing the notion of phantom energy, the equation of state generates a mathematical model that combines the generalized phantom energy and the generalized Chaplygin gas models.

Peter K. F. Kuhfittig

2009-04-22T23:59:59.000Z

494

Wireless channel characterization and modeling in oil and gas refinery plants  

E-Print Network (OSTI)

Wireless channel characterization and modeling in oil and gas refinery plants Stefano Savazzi1 modeling approach is validated by experimental measurements in two oil refinery sites using industry standard ISA SP100.11a compliant commercial devices operating at 2.4GHz. I. INTRODUCTION The adoption

Savazzi, Stefano

495

Oil and Gas CDT Development of a SUNTANS Baroclinic Model for 3D Oil  

E-Print Network (OSTI)

Oil and Gas CDT Development of a SUNTANS Baroclinic Model for 3D Oil Pollution Tracking Heriot) Key Words Oil Spill, HF Radar, Trajectory Forecasting, Hydrodynamic Modelling, Oil Chemistry Overview In an oil spill emergency, an operational system must forecast ocean and weather conditions in addition

Henderson, Gideon

496

Pre-Commercial Demonstration of Cost-Effective Advanced HVAC Controls- 2014 BTO Peer Review  

Energy.gov (U.S. Department of Energy (DOE))

Presenter: Hayden Reeve, United Technologies Research Center Optimal control coordination of heating, ventilation, and air conditioning (HVAC) equipment can reduce energy by more than 20% over current building automation systems (BASs) but is not widely deployed due to challenges with complexity, scalability, and deployment.

497

2014-04-28 Issuance: Certification of Commercial HVAC, Water Heating, and Refrigeration Equipment; Final Rule  

Energy.gov (U.S. Department of Energy (DOE))

This document is a pre-publication Federal Register final rule regarding the certification of commercial heating, ventilation, and air-conditioning (HVAC), water heating (WH), and refrigeration (CRE) equipment, as issued by the Deputy Assistant Secretary for Energy Efficiency on April 28, 2014.

498

IFC HVAC interface to EnergyPlus - A case of expanded interoperability for energy simulation  

SciTech Connect

Tedious manual input of data that define a building, its systems and its expected pattern of use and operating schedules for building energy performance simulation has in the past diverted time and resources from productive simulation runs. In addition to its previously released IFCtoIDF utility that semiautomates the import of building geometry, the new IFC HVAC interface to EnergyPlus (released at the end of 2003) makes it possible to import and export most of the data that define HVAC equipment and systems in a building directly from and to other IFC compatible software tools. This reduces the manual input of other data needed for successful simulation with EnergyPlus to a minimum. The main purpose of this new interface is to enable import of HVAC equipment and systems definitions, generated by other IFC compatible software tools (such as HVAC systems design tools) and data bases, into EnergyPlus, and to write such definitions contained in EnergyPlus input files to the original IFC files from which building geometry was extracted for the particular EnergyPlus input. In addition, this interface sets an example for developers of other software tools how to import and/or export data other than building geometry from and/or into EnergyPlus. This paper describes the necessary simplifications and shortcuts incorporated in this interface, its operating environment, interface architecture, and the basic conditions and methodology for its use with EnergyPlus.

Bazjanac, Vladimir; Maile, Tobias

2004-03-29T23:59:59.000Z

499

Building America Expert Meeting: Transitioning Traditional HVAC Contractors to Whole House Performance Contractors  

Energy.gov (U.S. Department of Energy (DOE))

This report outlines findings resulting from a U.S. Department of Energy Building America expert meeting held on March 29, 2011 by IBACOS to determine how HVAC companies can transition from a traditional contractor status to a service provider for whole house energy upgrade contracting.

500

Particle loading rates for HVAC filters, heat exchangers, and ducts Nomenclature  

E-Print Network (OSTI)

Particle loading rates for HVAC filters, heat exchangers, and ducts Nomenclature Afl surface area of floor (m2 ) bf fraction of bypass flow around the filter (dimensionless) Cout outdoor concentration on the filter per volume of air (mg/lm m3 ) Mf,tot total mass deposited on the filter per month of operation (g

Siegel, Jeffrey