Powered by Deep Web Technologies
Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Strengthening Building Retrofit Markets  

SciTech Connect (OSTI)

The Business Energy Financing (BEF) program offered commercial businesses in Michigan affordable financing options and other incentives designed to support energy efficiency improvements. We worked through partnerships with Michigan utilities, lenders, building contractors, trade associations, and other community organizations to offer competitive interest rates and flexible financing terms to support energy efficiency projects that otherwise would not have happened. The BEF program targeted the retail food market, including restaurants, grocery stores, convenience stores, and wholesale food vendors, with the goal of achieving energy efficiency retrofits for 2 percent of the target market. We offered low interest rates, flexible payments, easy applications and approval processes, and access to other incentives and rebates. Through these efforts, we sought to help customers strive for energy savings retrofits that would save 20 percent or more on their energy use. This program helped Michigan businesses reduce costs by financing energy efficient lighting, heating and cooling systems, insulation, refrigeration, equipment upgrades, and more. Businesses completed the upgrades with the help of our authorized contractors, and, through our lending partners, we provided affordable financing options.

Templeton, Mary [Michigan Saves; Jackson, Robert [Michigan Energy Office

2014-04-15T23:59:59.000Z

2

Building America Webinar: Retrofitting Central Space Conditioning...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Control strategies to improve hydronic space heating performance Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings - Control...

3

Building America Webinar: Retrofitting Central Space Conditioning...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Introduction Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings - Introduction This presentation serves as the introduction to...

4

Building Retrofits for Increased Protection Against Airborne  

E-Print Network [OSTI]

Building Retrofits for Increased Protection Against Airborne Chemical and Biological Releases of Standards and Technology William A. Jeffrey, Director Building Retrofits for Increased Protection Against Dols Heather Davis Priya Lavappa Amy Rushing Building and Fire Research Laboratory Prepared for: U

5

Retrofit Ventilation Strategies in Multifamily Buildings Webinar...  

Energy Savers [EERE]

Retrofit of Mass Masonry Wall Assemblies Building America Technlogy Solutions for New and Existing Homes: Interior Foundation Insulation Upgrade - Madison Residence (Fact Sheet)...

6

Building America Expert Meeting: Interior Insulation Retrofit...  

Broader source: Energy.gov (indexed) [DOE]

Building Science Corporation team held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011, at the Westford Regency Hotel in...

7

A Methodology for Identifying Retrofit Energy Savings in Commercial Buildings  

E-Print Network [OSTI]

Measured energy savings resulting from energy conservation retrofits in commercial buildings can be used to verify the success of the retrofits, determine the payment schedule for the retrofits, and guide the selection of future retrofits...

Kissock, K.; Reddy, A.; Claridge, D.

8

Monitoring conservative retrofits in single family buildings  

SciTech Connect (OSTI)

This study has provided detailed before-and-after information on the ambient and comfort conditions in nine single family buildings, and on the energy consumption of those buildings, for one or more energy conservation retrofits. The data were recorded in such a manner that as well as being able to determine the savings from the retrofits and the influence these retrofits have on the comfort conditions of the residence, the effects of the retrofits on time-of-day usage are also determinable. The following are included in appendices: a table of participant's names, site addresses and retrofit; significant dates and appropriate comments; a day of data and an annotated data set; pre-retrofit and post-retrofit audit data sheets; and usage history.

Richardson, C.S.

1992-12-06T23:59:59.000Z

9

BetterBuildings Financing Energy Efficiency Retrofits in the...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

BetterBuildings Financing Energy Efficiency Retrofits in the Commercial Sector - Part 1 BetterBuildings Financing Energy Efficiency Retrofits in the Commercial Sector - Part 1...

10

Residential Building Audits and Retrofits | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Residential Building Audits and Retrofits Residential Building Audits and Retrofits Blue version of the EERE PowerPoint template, for use with PowerPoint 2007. Transcript...

11

Making your Building Smarter : The Retrofit Challenge  

E-Print Network [OSTI]

Wireless Temp Sensors IBM Dublin Research Labs : Smart Buildings Living Lab Environment Background ? 2012 IBM Corporation IBM Dublin Research Labs Our Smart Building Retrofit Challenges Retrofit Challenges Summary 1. Smart Building Design 2... Comfortable environment ?Reduce Energy/Water usage environment ?Keep within Budget ?Biggest Challenge ?? Constantly competing (& changing) objectives within the design and build cycles What to include ? What is critical? Where to Invest ? 5 ? 2012...

Brady, N.

2012-01-01T23:59:59.000Z

12

Building America Expert Meeting Report: Interior Insulation Retrofit...  

Broader source: Energy.gov (indexed) [DOE]

Interior Insulation Retrofit of Mass Masonry Wall Assembliesessment of risk factors for premature building deterioration due to interior insulation retrofits, and methods to reduce...

13

Energy Efficient Retrofits and Green Building Practices  

E-Print Network [OSTI]

. Moreover, the increase in demand is also causing rise in pollution levels. Therefore, the subject of energy efficient retrofits and green building practices is becoming increasingly important. Based on the latest walkthrough energy audit it is proven...

Rahman, M.

2010-01-01T23:59:59.000Z

14

Building Energy Model Development for Retrofit Homes  

SciTech Connect (OSTI)

Based on previous research conducted by Pacific Northwest National Laboratory and Florida Solar Energy Center providing technical assistance to implement 22 deep energy retrofits across the nation, 6 homes were selected in Florida and Texas for detailed post-retrofit energy modeling to assess realized energy savings (Chandra et al, 2012). However, assessing realized savings can be difficult for some homes where pre-retrofit occupancy and energy performance are unknown. Initially, savings had been estimated using a HERS Index comparison for these homes. However, this does not account for confounding factors such as occupancy and weather. This research addresses a method to more reliably assess energy savings achieved in deep energy retrofits for which pre-retrofit utility bills or occupancy information in not available. A metered home, Riverdale, was selected as a test case for development of a modeling procedure to account occupancy and weather factors, potentially creating more accurate estimates of energy savings. This “true up” procedure was developed using Energy Gauge USA software and post-retrofit homeowner information and utility bills. The 12 step process adjusts the post-retrofit modeling results to correlate with post-retrofit utility bills and known occupancy information. The “trued” post retrofit model is then used to estimate pre-retrofit energy consumption by changing the building efficiency characteristics to reflect the pre-retrofit condition, but keeping all weather and occupancy-related factors the same. This creates a pre-retrofit model that is more comparable to the post-retrofit energy use profile and can improve energy savings estimates. For this test case, a home for which pre- and post- retrofit utility bills were available was selected for comparison and assessment of the accuracy of the “true up” procedure. Based on the current method, this procedure is quite time intensive. However, streamlined processing spreadsheets or incorporation into existing software tools would improve the efficiency of the process. Retrofit activity appears to be gaining market share, and this would be a potentially valuable capability with relevance to marketing, program management, and retrofit success metrics.

Chasar, David; McIlvaine, Janet; Blanchard, Jeremy; Widder, Sarah H.; Baechler, Michael C.

2012-09-30T23:59:59.000Z

15

Phillip Burton Federal Building EMCS Retrofit Analysis  

E-Print Network [OSTI]

and Renewable Energy, Office of Building Technology and Community Systems, and the Federal Energy ManagementPhillip Burton Federal Building EMCS Retrofit Analysis Interim Report March 1999 Rick Diamond, Tim This report presents the interim results of analyses carried out in the Phillip Burton Federal Building in San

Diamond, Richard

16

Advanced Energy Retrofit Guide Retail Buildings  

SciTech Connect (OSTI)

The Advanced Energy Retrofit Guide for Retail Buildings is a component of the Department of Energy’s Advanced Energy Retrofit Guides for Existing Buildings series. The aim of the guides is to facilitate a rapid escalation in the number of energy efficiency projects in existing buildings and to enhance the quality and depth of those projects. By presenting general project planning guidance as well as financial payback metrics for the most common energy efficiency measures, these guides provide a practical roadmap to effectively planning and implementing performance improvements for existing buildings.

Liu, Guopeng; Liu, Bing; Zhang, Jian; Wang, Weimin; Athalye, Rahul A.; Moser, Dave; Crowe, Eliot; Bengtson, Nick; Effinger, Mark; Webster, Lia; Hatten, Mike

2011-09-19T23:59:59.000Z

17

Advanced Energy Retrofit Guide Office Buildings  

SciTech Connect (OSTI)

The Advanced Energy Retrofit Guide for Office Buildings is a component of the Department of Energy’s Advanced Energy Retrofit Guides for Existing Buildings series. The aim of the guides is to facilitate a rapid escalation in the number of energy efficiency projects in existing buildings and to enhance the quality and depth of those projects. By presenting general project planning guidance as well as financial payback metrics for the most common energy efficiency measures, these guides provide a practical roadmap to effectively planning and implementing performance improvements for existing buildings.

Liu, Guopeng; Liu, Bing; Wang, Weimin; Zhang, Jian; Athalye, Rahul A.; Moser, Dave; Crowe, Eliot; Bengtson, Nick; Effinger, Mark; Webster, Lia; Hatten, Mike

2011-09-27T23:59:59.000Z

18

"We retrofitted mechanical systems in 8 buildings!"  

E-Print Network [OSTI]

"We retrofitted mechanical systems in 8 buildings!" LOW INTEREST RATE LOANS AVAILABLE NOW! County of Contra Costa California Energy Commission Apply Today! See Case Study on Back of Flyer "Our low interest and cooling systems in eight buildings. The energy efficient measures include replacing pneumatic controls

19

Evaluation of Crawlspace Retrofits in Multifamily Buildings  

SciTech Connect (OSTI)

In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community unvented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre- and post-retrofit evaluation, testing, and data monitoring. The existing condition was a vented crawlspace with an uninsulated floor between the crawlspace and the dwelling units above. The crawlspace was therefore a critically weak link in the building enclosure and was ripe for improvement. Saving energy was the primary interest and goal, but the greatest challenge in this unvented crawlspace retrofit project was working through a crawlspace bulk water intrusion problem caused by inadequate site drainage, window well drainage, foundation wall drainage, and a rising water table during rainy periods. While the unvented crawlspace retrofit was effective in reducing heat loss, and the majority of the bulk water drainage problems had been resolved, the important finding was that some of the wood joists embedded in masonry pockets behind the brick veneer were showing signs of moisture damage.

Rudd, A.

2014-09-01T23:59:59.000Z

20

Measuring retrofit savings in commercial buildings with pre-retrofit utility billing data and post-retrofit sub-metered data  

E-Print Network [OSTI]

Methodologies to measure energy and dollar savings resulting from energy conserving retrofits in commercial buildings when both pre-retrofit and post-retrofit monitored data are available at an hourly or daily level have already been developed...

Liu, Yue

1993-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Ready to Retrofit: The Process of Project Team Selection, Building  

E-Print Network [OSTI]

, and Financing Commercial Building Energy Retrofit Projects Mark D. Sanders, Kristen Parrish, Paul Mathew for the Commercial Buildings Partnership (CBP) program, sponsored by the U.S. Department of Energy's Building a process for three key activities for the building owner in preparing to retrofit existing commercial

22

Monitoring conservative retrofits in single family buildings. Final technical report  

SciTech Connect (OSTI)

This study has provided detailed before-and-after information on the ambient and comfort conditions in nine single family buildings, and on the energy consumption of those buildings, for one or more energy conservation retrofits. The data were recorded in such a manner that as well as being able to determine the savings from the retrofits and the influence these retrofits have on the comfort conditions of the residence, the effects of the retrofits on time-of-day usage are also determinable. The following are included in appendices: a table of participant`s names, site addresses and retrofit; significant dates and appropriate comments; a day of data and an annotated data set; pre-retrofit and post-retrofit audit data sheets; and usage history.

Richardson, C.S.

1992-12-06T23:59:59.000Z

23

A Methodology to Measure Retrofit Energy Savings in Commercial Buildings  

E-Print Network [OSTI]

. This dissertation develops a methodology to measure retrofit energy savings and the uncertainty of the savings in commercial buildings. The functional forms of empirical models of cooling and heating energy use in commercial buildings are derived from an engineering...

Kissock, John Kelly

2008-01-16T23:59:59.000Z

24

DOE Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings  

Broader source: Energy.gov [DOE]

The Building America Program is hosting a no-cost, webinar-based training on Retrofitting Central Space Conditioning Strategies for Multifamily Buildings. The webinar will focus on improving the...

25

The retrofitting of existing buildings for seismic criteria  

E-Print Network [OSTI]

This thesis describes the process for retrofitting a building for seismic criteria. It explains the need for a new, performance-based design code to provide a range of acceptable building behavior. It then outlines the ...

Besing, Christa, 1978-

2004-01-01T23:59:59.000Z

26

Text-Alternative Version of Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings  

Broader source: Energy.gov [DOE]

A text-alternative version of the Building America webinar, Retrofitting Central Space Conditioning Strategies for Multifamily Buildings held on July 16, 2014.

27

Retrofit of a Multifamily Mass Masonry Building in New England  

SciTech Connect (OSTI)

Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goals but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.

Ueno, K.; Kerrigan, P.; Wytrykowska, H.; Van Straaten, R.

2013-08-01T23:59:59.000Z

28

City of Los Angeles- Green Building Retrofit Requirement  

Broader source: Energy.gov [DOE]

In April 2009, Los Angeles enacted [clkrep.lacity.org/onlinedocs/2006/06-1963_ord_180633.pdf Ordinance 180636], known as the Green Building Retrofit Ordinance. This ordinance was later amended by...

29

Commercial Building Funding Opportunity Webinar  

Broader source: Energy.gov [DOE]

This webinar provide an overview of the Commercial Building Technology Demonstrations Funding Opportunity Announcement DE-FOA-0001084.

30

A Retrofit Tool for Improving Energy Efficiency of Commercial Buildings  

SciTech Connect (OSTI)

Existing buildings will dominate energy use in commercial buildings in the United States for three decades or longer and even in China for the about two decades. Retrofitting these buildings to improve energy efficiency and reduce energy use is thus critical to achieving the target of reducing energy use in the buildings sector. However there are few evaluation tools that can quickly identify and evaluate energy savings and cost effectiveness of energy conservation measures (ECMs) for retrofits, especially for buildings in China. This paper discusses methods used to develop such a tool and demonstrates an application of the tool for a retrofit analysis. The tool builds on a building performance database with pre-calculated energy consumption of ECMs for selected commercial prototype buildings using the EnergyPlus program. The tool allows users to evaluate individual ECMs or a package of ECMs. It covers building envelope, lighting and daylighting, HVAC, plug loads, service hot water, and renewable energy. The prototype building can be customized to represent an actual building with some limitations. Energy consumption from utility bills can be entered into the tool to compare and calibrate the energy use of the prototype building. The tool currently can evaluate energy savings and payback of ECMs for shopping malls in China. We have used the tool to assess energy and cost savings for retrofit of the prototype shopping mall in Shanghai. Future work on the tool will simplify its use and expand it to cover other commercial building types and other countries.

Levine, Mark; Feng, Wei; Ke, Jing; Hong, Tianzhen; Zhou, Nan

2013-06-06T23:59:59.000Z

31

Research on Commercial Patterns of China Existing Building Energy Retrofit Based on Energy Management Contract  

E-Print Network [OSTI]

Existing building energy retrofit is one of the keys of building energy efficiency in China. According to experience in developed countries, implementation of energy management contract (EMC) is crucial to promote existing building energy retrofit...

Han, Z.; Liu, C.; Sun, J.

2006-01-01T23:59:59.000Z

32

Hungary-Employment Impacts of a Large-Scale Deep Building Retrofit...  

Open Energy Info (EERE)

Deep Building Retrofit Programme AgencyCompany Organization European Climate Foundation Sector Energy Focus Area Energy Efficiency, Buildings, - Building Energy Efficiency...

33

An actuarial approach to retrofit savings in buildings  

SciTech Connect (OSTI)

An actuarial method has been developed for determining energy savings from retrofits from energy use data for a number of buildings. This method should be contrasted with the traditional method of using pre- and post-retrofit data on the same building. This method supports the U.S. Department of Energy Building Performance Database of real building performance data and related tools that enable engineering and financial practitioners to evaluate retrofits. The actuarial approach derives, from the database, probability density functions (PDFs) for energy savings from retrofits by creating peer groups for the user’s pre post buildings. From the energy use distribution of the two groups, the savings PDF is derived. This provides the basis for engineering analysis as well as financial risk analysis leading to investment decisions. Several technical issues are addressed: The savings PDF is obtained from the pre- and post-PDF through a convolution. Smoothing using kernel density estimation is applied to make the PDF more realistic. The low data density problem can be mitigated through a neighborhood methodology. Correlations between pre and post buildings are addressed to improve the savings PDF. Sample size effects are addressed through the Kolmogorov--Smirnov tests and quantile-quantile plots.

Subbarao, Krishnappa; Etingov, Pavel V.; Reddy, T. A.

2014-01-01T23:59:59.000Z

34

Retrofit Ventilation Strategies in Multifamily Buildings Webinar |  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartment of Energy fromComments onReplyofRetiring Procurement OfficialRetrofit

35

Retrofitting Existing Buildings for Demand Response & Energy Efficiency  

E-Print Network [OSTI]

partnership) · Plug loads, data centers ­ remainder (solution: WTR, WBM) Source: US Energy Information, higher "critical peak" energy charges will be assessed for usage between noon and 6pm. - CustomersRetrofitting Existing Buildings for Demand Response & Energy Efficiency www

California at Los Angeles, University of

36

Building America Webinar: Who's Successfully Doing Deep Energy Retrofits?  

Broader source: Energy.gov [DOE]

The webinar on June 25, 2014, focused on specific Building America projects that highlighted real-world examples of deep energy retrofits (DER) that are meeting with technical and market success. Presenters focused on technical strategies, modeled and actual performance results, and project costs.

37

Building America Webinar: Who's Successfully Doing Deep Energy Retrofits?  

Broader source: Energy.gov [DOE]

The webinar will focus on specific Building America projects and case studies that highlight real-world examples of deep energy retrofits that are meeting with technical and market success. Presenters will focus on technical strategies, modeled and actual performance results, and project costs.

38

Need for Systematic Retrofit Analysis in Multifamily Buildings  

SciTech Connect (OSTI)

Multifamily housing offers high potential for energy savings through retrofits. A comprehensive energy audit with systematic evaluation of alternative energy measures is one of the key steps to realizing the full energy savings potential. However, this potential often remains unrealized when the selection of measures is (1) based on a one-size-fits-all approach originating from accustomed practices, (2) intended merely to meet code-compliance requirements, and/or (3) influenced by owner renter split incentive. In such cases, the benefits of comprehensive energy auditing are disregarded in view of the apparent difficulty in diagnosing multifamily buildings, evaluating alternative measures, and installing customized sets of measures. This paper highlights some of the barriers encountered in a multifamily housing retrofit project in Georgia and demonstrates the merits of systematic retrofit analysis by identifying opportunities for higher energy savings and improved comfort and indoor air quality that were missed in this project. The study uses a whole-building energy analysis conducted for a 10-unit, low-rise, multifamily building of a 110-unit apartment complex. The analysis projected a 24% energy savings from the measures installed in the building with a payback period of 10 years. Further analysis with a systematic evaluation of alternative measures showed that without compromising on the objectives of durability, livability, and appearance of the building, energy savings of up to 34% were achievable with a payback period of 7 years. The paper concludes by outlining recommendations that may benefit future retrofit projects by improving the audit process, streamlining tasks, and achieving higher energy savings.

Malhotra, Mini [ORNL; Im, Piljae [ORNL

2014-01-01T23:59:59.000Z

39

How Do We Retrofit the Tough Buildings  

Broader source: Energy.gov [DOE]

This presentation was delivered at the U.S. Department of Energy Building America Technical Update meeting on April 29-30, 2013, in Denver, Colorado.

40

Building America Webinar: Retrofitting Central Space Conditioning...  

Broader source: Energy.gov (indexed) [DOE]

buildings in Cambridge, MA. Presenters showed results from an analysis of three boiler control strategies, more aggressive outdoor rest curves, nighttime setback of supply...

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Analysis of institutional mechanisms affecting residential and commercial buildings retrofit  

SciTech Connect (OSTI)

Barriers to energy conservation in the residential and commercial sectors influence (1) the willingness of building occupants to modify their energy usage habits, and (2) the willingness of building owners/occupants to upgrade the thermal characteristics of the structures within which they live or work and the appliances which they use. The barriers that influence the willingness of building owners/occupants to modify the thermal efficiency characteristics of building structures and heating/cooling systems are discussed. This focus is further narrowed to include only those barriers that impede modifications to existing buildings, i.e., energy conservation retrofit activity. Eight barriers selected for their suitability for Federal action in the residential and commercial sectors and examined are: fuel pricing policies that in the short term do not provide enough incentive to invest in energy conservation; high finance cost; inability to evaluate contractor performance; inability to evaluate retrofit products; lack of well-integrated or one-stop marketing systems (referred to as lack of delivery systems); lack of precise or customized information; lack of sociological/psychological incentives; and use of the first-cost decision criterion (expanded to include short-term payback criterion for the commercial sector). The impacts of these barriers on energy conservation are separately assessed for the residential and commercial sectors.

Not Available

1980-09-01T23:59:59.000Z

42

Determination of Retrofit Savings Using a Calibrated Building Energy Simulation Model  

E-Print Network [OSTI]

This paper presents the development of a methodology to determine retrofit energy savings in buildings when few measured preretrofit data are available. Calibration of the DOE-2 building energy analysis computer program for a 250,000 ft2 building...

Reddy, S. N.; Hunn, B. D.; Hood, D. B.

1994-01-01T23:59:59.000Z

43

Building America Webinar: Retrofitting Central Space Conditioning  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 < prev next >researchNewBuildings Webinar

44

Building America Webinar: Retrofitting Central Space Conditioning  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 < prev next >researchNewBuildings

45

Building America Webinar: Retrofitting Central Space Conditioning  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 < prev next >researchNewBuildingsStrategies for

46

Sustainable Building Design Revolving Loan Fund  

Broader source: Energy.gov [DOE]

The Sustainable Building Design Revolving Loan Fund (RLF) is funded by the American Recovery and Reinvestment Act of 2009 (ARRA). The Arkansas Energy Office granted the Arkansas Building Authority ...

47

Analysis Methodology for Large Organizations' Investments in Energy Retrofit of Buildings  

E-Print Network [OSTI]

This paper presents a formal methodology that supports large organizations' investments in energy retrofit of buildings. The methodology is a scalable modeling approach based on normative models and Bayesian calibration. Normative models are a light...

Heo, Y.; Augenbroe, G.

2011-01-01T23:59:59.000Z

48

Assessing methods for predicting retrofit energy savings in buildings : case study of a Norwegian school  

E-Print Network [OSTI]

This work investigates methods for predicting retrofit energy savings in existing Norwegian buildings. A case study is performed on a 30 year old primary school in Trondheim, Norway. The energy consumption in the school ...

Ricker, Elizabeth, S.M. (Elizabeth Ann). Massachusetts Institute of Technology

2008-01-01T23:59:59.000Z

49

Building America Webinar: Standardized Retrofit Packages — What Works to Meet Consistent Levels of Performance?  

Broader source: Energy.gov [DOE]

This webinar will focus on specific Building America projects that have examined methods to consistently meet high levels of energy performance in existing homes, with a focus on retrofit packages that can be replicated across many homes.

50

Modelling Urban scale Retrofit, Pathways to 2050 Low Carbon Residential Building Stock   

E-Print Network [OSTI]

A bottom up engineering modelling approach has been used to investigate the pathways to 2050 low carbon residential building stock. The impact of housing retrofit, renewable technologies, occupant behaviour, and grid decarbonisation is measured at a...

Lannon, Simon; Georgakaki, Aliki; Macdonald, Stuart

51

State Energy Program (SEP) Strengthening Building Retrofit Markets and Stimulating Energy Efficiency Action  

Broader source: Energy.gov [DOE]

National Energy Technology Laboratory (NETL) presentation on State Energy Program (SEP) Strengthening Building Retrofit Markets and Stimulating Energy Efficiency Action DE-FOA-0000251, Stimulating Energy Efficiency Action from State Public Utility Commissions DE-FOA-0000266

52

Decision process for the retrofit of municipal buildings with solar energy systems: a technical guide  

SciTech Connect (OSTI)

As a background for solar applications, the following topics are covered: solar systems and components for retrofit installations; cost, performance, and quality considerations; and financing alternatives for local government. The retrofit decision process is discussed as follows: pre-screening of buildings, building data requirements, the energy conservation audit, solar system sizing and economics, comparison of alternatives, and implementation. Sample studies are presented for the West Valley Animal Shelter and the Hollywood Police Station. (MHR)

None

1980-11-01T23:59:59.000Z

53

Now Accepting Applications: BUILD Funding Opportunity | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

November 14, 2014 5:00PM EST to December 19, 2014 5:00PM EST Through its annual Buildings University Innovators and Leaders Development (BUILD) funding opportunity, the Energy...

54

Data and Analytics to Inform Energy Retrofit of High Performance Buildings  

SciTech Connect (OSTI)

Buildings consume more than one-third of the world?s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energy audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis ? energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high performance building in California to analyze its energy use and identify retrofit opportunities, including: (1) analyzing patterns of major energy end-use categories at various time scales, (2) benchmarking the whole building total energy use as well as major end-uses against its peers, (3) benchmarking the power usage effectiveness for the data center, which is the largest electricity consumer in this building, and (4) diagnosing HVAC equipment using detailed time-series operating data. Finally, a few energy efficiency measures were identified for retrofit, and their energy savings were estimated to be 20percent of the whole-building electricity consumption. Based on the analyses, the building manager took a few steps to improve the operation of fans, chillers, and data centers, which will lead to actual energy savings. This study demonstrated that there are energy retrofit opportunities for high performance buildings and detailed measured building performance data and analytics can help identify and estimate energy savings and to inform the decision making during the retrofit process. Challenges of data collection and analytics were also discussed to shape best practice of retrofitting high performance buildings.

Hong , Tianzhen; Yang, Le; Hill, David; Feng , Wei

2014-01-25T23:59:59.000Z

55

Nevada: Vegas Retrofits through Building America Enhance Home Performance  

Office of Energy Efficiency and Renewable Energy (EERE)

The EERE report Retrofitting Vegas: Implementing Energy Efficiency in Two Las Vegas Test Home notes that during the housing crisis, more than 11% of the existing housing stock in Las Vegas is in foreclosure (more than 8,100 homes). There is strong potential for achieving significant energy savings through retrofit activities in this region.

56

Funding Opportunity Webinar- Buildings University Innovators and Leaders Development (BUILD)  

Broader source: Energy.gov [DOE]

This webinar provides an overview of the “Buildings University Innovators and Leaders Development (BUILDFunding Opportunity Announcement, DE-FOA-0001167. The webinar was originally presented on November 19, 2014.

57

Simulated Energy Savings Comparison Between Two Continuous Commissioning® Methods Applied to a Retrofitted Office Building  

E-Print Network [OSTI]

The 8 th International Conference for Enhanced Building Operations (ICEBO 2008) October 20-22, 2008, Berlin, Germany Simulated Energy Savings Comparison Between Two Continuous Commissioning ? Methods Applied to a Retrofitted Office Building... and the cold and hot 1 ESL-IC-08-10-30 Proceedings of the Eighth International Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 The 8 th International Conference for Enhanced Building Operations (ICEBO 2008) October 20...

Texas A& M Campus Building CC® Team

58

Building Requirements for State-Funded Buildings  

Broader source: Energy.gov [DOE]

New Hampshire enacted legislation (SB 409) in July 2010 stipulating that "major" construction and maintenance projects that receive state funding must meet a high-performance energy and design...

59

Retrofit of Existing Residential Building: a Case Study  

E-Print Network [OSTI]

was reasonable, the construction quality was not good. The air leak from the circumference of window was serious and some inner surface of external walls formed condensation of moisture. Before retrofit, the annual heating energy consumption was 9.28?108kJ.... The annual coal consumption for heating was 31.68 tons standard coal. After retrofit, the annual heat consumption was 6.73?108kJ. The annual coal consumption for heating was 22.97 tons standard coal. With the 2.55?108kJ reduction of the annual heating...

Zhao, L.; Xu, W.; Li, L.; Gao, G.

2006-01-01T23:59:59.000Z

60

Strategy Guideline: Energy Retrofits for Low-Rise Multifamily Buildings in Cold Climates  

SciTech Connect (OSTI)

This Strategy Guideline explains the benefits of evaluating and identifying energy efficiency retrofit measures that could be made during renovation and maintenance of multifamily buildings. It focuses on low-rise multifamily structures (three or fewer stories) in a cold climate. These benefits lie primarily in reduced energy use, lower operating and maintenance costs, improved durability of the structure, and increased occupant comfort. This guideline focuses on retrofit measures for roof repair or replacement, exterior wall repair or gut rehab, and eating system maintenance. All buildings are assumed to have a flat ceiling and a trussed roof, wood- or steel-framed exterior walls, and one or more single or staged boilers. Estimated energy savings realized from the retrofits will vary, depending on the size and condition of the building, the extent of efficiency improvements, the efficiency of the heating equipment, the cost and type of fuel, and the climate location.

Frozyna, K.; Badger, L.

2013-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

A Retrofit Tool for Improving Energy Efficiency of Commercial Buildings  

E-Print Network [OSTI]

For Energy Efficiency of Public Building -- GB 50189.communication on building energy efficiency policy in China.Improving energy efficiency in existing buildings. ASHRAE

Levine, Mark

2014-01-01T23:59:59.000Z

62

Business Case for Energy Efficient Building Retrofit and Renovation...  

Energy Savers [EERE]

More Documents & Publications Energy Efficiency Trends in Residential and Commercial Buildings - August 2010 Marketing and Market Transformation Building America...

63

RETROFIT: A SOFTWARE TO SOLVE OPTIMIZATION AND IDENTIFICATION PROBLEMS APPLIED TO BUILDING ENERGY  

E-Print Network [OSTI]

under forecast weather or use conditions. Demand response strategies in smart grids consist in adjusting- els. ReTrofiT is first of all a simulation tool for evaluating building thermal behaviour can be obtained if the internal parameters of the model are calibrated using on-site measurements

Boyer, Edmond

64

Byggmeister Test Home: Cold Climate Multifamily Masonry Building Condition Assessment and Retrofit Analysis  

SciTech Connect (OSTI)

This report describes a retrofit project undertaken by Building Science Corporation and partner Byggmeister on a multifamily brick row house located in Jamaica Plain, MA. This project studied the row house to determine the right combination of energy efficiency measures that are feasible, affordable, and suitable for this type of construction and acceptable to homeowners.

Wytrykowska, H.; Ueno, K.; Van Straaten, R.

2012-09-01T23:59:59.000Z

65

Building America Case Study: Performance of a Hot-Dry Climate Whole House Retrofit, Stockton, California (Fact Sheet)  

SciTech Connect (OSTI)

The Stockton house retrofit is a two-story tudor style single family deep retrofit in the hot-dry climate of Stockton, CA. The home is representative of a deep retrofit option of the scaled home energy upgrade packages offered to targeted neighborhoods under the pilot Large-Scale Retrofit Program (LSRP) administered by the Alliance for Residential Building Innovation (ARBI). Deep retrofit packages expand on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Site energy savings with the deep retrofit were 23% compared to the pre-retrofit case, and 15% higher than the savings estimated for the standard retrofit package. Energy savings were largely a result of the water heater upgrade, and a combination of the envelope sealing, insulation and HVAC upgrade. The HVAC system was of higher efficiency than the building code standard. Overall the financed retrofit would have been more cost effective had a less expensive HVAC system been selected and barriers to wall insulation remedied. The homeowner experienced improved comfort throughout the monitored period and was satisfied with the resulting utility bill savings.

ARBI

2014-09-01T23:59:59.000Z

66

Simulation of the Post-Retrofit Thermal Energy Use for the Perry-Castaneda Library Building with the Use of Simplified System Models  

E-Print Network [OSTI]

. One method of determining the energy savings resulting from energy conserving retrofits relies on the use of a model for the daily whole building consumption, Epre, in the pre-retrofit configuration. Epre is typically a function of primary influencing...

Katipamula, S.; Claridge, D. E.

1991-01-01T23:59:59.000Z

67

Opportunities and Challenges in Whole-Building Retrofits  

E-Print Network [OSTI]

, life-cycle analysis of buildings, brownfield redevelopment, and preservation. Then, existing writing

Hoffman, Andrew J.

68

A systematic approach to energy efficiency retrofit solutions for exsisting office buildings  

E-Print Network [OSTI]

Institute of Energy Efficient and Sustainable Design and Building Prof. Dr.-Ing. Werner Lang Yunming Shao Prof. Dr.-Ing. Werner Lang Technical University of Munich, Germany 11/11/2014 A systematic approach to energy efficiency retrofit solutions... for existing office buildings ESL-IC-14-09-33 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 Institute of Energy Efficient and Sustainable Design and Building Prof. Dr.-Ing. Werner Lang...

Shao,Y.

2014-01-01T23:59:59.000Z

69

Retrofitting of Conditioning Systems for Existing Small Commercial Buildings - Analysis and Design of Liquid Desiccant - Vapor Compression Hybrid  

E-Print Network [OSTI]

and limitations of retrofit technology for these characteristic structures have been the focus of the experience gained through the design and installation of a system adapted to a building constructed in the early 1960's. The existing split package air...

Arnas, O. A.; McQueen, T. M.

1984-01-01T23:59:59.000Z

70

Webinar: Learn about the BUILD funding opportunity | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

19, 2014 | 3pm to 4pm EST The Energy Department announces the 1 million Buildings University Innovators and Leaders Development (BUILD) Funding Opportunity Announcement...

71

Instrumenting Buildings to Determine Retrofit Savings: Murphy's Law Revisited  

E-Print Network [OSTI]

the whole building electric load, building thermal loads and selected submetered loads. The emphasis of the lessons learned is on the instrumentation used and installation problems encountered during this project. INTRODUCTION During the past three and one..." should be able to avoid them. However, even experienced installers of building energy metering systems seem to struggle with some of these "obvious" problems and if a solution is developed, often there is no written record left for future reference...

Boecker, C. L.; Bohmer, C.; O'Neal, D. L.; Bryant, J.

72

Building America Best Practices Series, Vol. 10 - Retrofit Techniques...  

Broader source: Energy.gov (indexed) [DOE]

air leaks in homes, while ensuring healthy levels of ventilation and avoiding indoor air pollution. baairsealingreport.pdf More Documents & Publications Building America...

73

Building energy retrofitting: from energy audit to renovation proposals.  

E-Print Network [OSTI]

?? Abstract The built environment is responsible for 40% of the global energy demand (1). To reduce building energy consumption, regulations are enhancing the appeal… (more)

Clément, Paul Francois

2012-01-01T23:59:59.000Z

74

The Great Building Energy Predictor Shootout II: Measuring Retrofit Energy Savings  

E-Print Network [OSTI]

the MCC savings. Energy Systems Laboratory Texas A&M University Texas Engineering Experiment Station College Station, TX 77843-3581 ASHRAE Predictor Shootout H, p 4 BUS Savings Comparisons . ? In the BUS building, the savings were calculated using... Energy Systems Laboratory Texas A & M University Texas Engineering Experiment Station College Station, TX 77843-3581 ASHRAE Predictor Shootout II, p 6 Table 1: The Completed Entries received for the Predictor Shootout II: Measuring Retrofit Energy Savings...

Thamilseran, S.; Haberl, J. S.

1995-01-01T23:59:59.000Z

75

Residential Retrofit Program Design Guide  

Broader source: Energy.gov [DOE]

This Residential Retrofit Program Design Guide focuses on the key elements and design characteristics of building and maintaining a successful residential retrofit program.

76

Instrumenting Buildings to Determine Retrofit Savings: Murphy's Law Strikes Again  

E-Print Network [OSTI]

&M University. Metering typically includes monitoring for the whole-building electric load, chilled and hot water thermal loads and selected submetered electrical loads. The emphasis of the lessons learned was on the instrumentation used and installation...

O'Neal, D. L.; Bryant, J.; Carlson, K.

1998-01-01T23:59:59.000Z

77

New Jersey SmartStart Buildings- New Construction and Retrofits  

Broader source: Energy.gov [DOE]

New Jersey SmartStart Buildings is a program sponsored by the New Jersey Board of Public Utilities in partnership with New Jersey’s gas and electric utilities. The program has three main project...

78

An Overview of the Building Energy Retrofit Research Program  

E-Print Network [OSTI]

This research update presents the status of a U.S. Department of Energy program that addresses the technical, financial, and behavioral barriers to improving the energy efficiency of existing buildings. The program is implemented with expertise from...

Mixon, W. R.

1988-01-01T23:59:59.000Z

79

Seismic retrofit of precast panel buildings in Eastern Europe  

E-Print Network [OSTI]

Many countries in Eastern Europe, particularly ones from the former Soviet Bloc, are facing a potential crisis regarding their deteriorating precast panel apartment buildings. These complexes were built using industrial ...

Tzonev, Tzonu

2013-01-01T23:59:59.000Z

80

Standard Measurement and Verification Plan for Lighting Retrofit Projects for Buildings and Building Sites  

SciTech Connect (OSTI)

This document provides a framework for standard measurement and verification (M&V) of lighting retrofit and replacement projects. It was developed to provide site owners, contractors, and other involved organizations with the essential elements of a robust M&V plan for lighting projects. It includes details on all aspects of effectively measuring light levels of existing and post-retrofit projects, conducting power measurement, and developing cost-effectiveness analysis. This framework M&V plan also enables consistent comparison among similar lighting projects, and may be used to develop M&V plans for non--lighting-technology retrofits and new installations.

Richman, Eric E.

2012-10-31T23:59:59.000Z

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

The Value of the EWIT Computer Program in Identifying Economically Viable Retrofit Options for Existing Commercial Buildings  

E-Print Network [OSTI]

EWIT's potential as a tool for evaluating retrofit options for existing commercial buildings. To achieve this goal two case buildings in the Denver area were analyzed by means of the EWIT program. The first building is a one story structure of 10...

Andrews, W. M.

1984-01-01T23:59:59.000Z

82

Retrofit Incentives for Multifamily Buildings | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in3.pdfEnergyDepartmentEnergyHydrokineticClothes7, 2014 -ReportingFundsWeatherization

83

Business Case for Energy Efficient Building Retrofit and Renovation |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top FiveDepartment of Energy BuildingsBuried and

84

Building America Webinar: Retrofit Ventilation Strategies in Multifamily  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 < prev next >researchNewBuildings Webinar |

85

Building America Webinar: Who's Successfully Doing Deep Energy Retrofits?  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 < prev next >researchNewBuildingsStrategies|of

86

Business Case for Energy Efficient Building Retrofit and Renovation  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 < prevBuilding theINNOVATIONof Energy

87

Impact evaluation of the energy retrofits installed in the Margolis high-rise apartment building, Chelsea housing authority  

SciTech Connect (OSTI)

As part of a joint demonstration effort involving HUD, DOE, a local public housing authority and Boston Edison, an evaluation of energy and demand saving retrofits was conducted for a tall, residential, low-income building located in Boston. The thirteen story building underwent window, lighting, and heating system control renovations in December, 1992. The success of these retrofits was determined using monthly and hourly whole-building consumption data along with a calibrated DOE-2.1D energy simulation model. According to the model developed, post-retrofit conditions showed reductions in annual energy consumption of 325 MWh and in peak demand of 100 kW. These savings resulted in an annual energy cost savings of $28,000. Over 90% of energy and cost savings were attributed to the window retrofit. Interaction of the reduction in lighting capacity with the building`s electric resistance heating system reduced the potential for energy and demand savings associated with the lighting retrofit. Results from the hourly simulation model also indicate that night setbacks controlled by the energy management system were not implemented. An additional 32 MWh in energy savings could be obtained by bringing this system on-line, however peak demand would be increased by 40 kW as the morning demand for space heat is increased, with a net loss in cost savings of $2,500.

Abraham, M.M.; McLain, H.A.; MacDonald, J.M.

1995-03-01T23:59:59.000Z

88

Funding Opportunity Webinar, Buildings University Innovators and Leaders Development-- BUILD (Text Version)  

Broader source: Energy.gov [DOE]

Below is the text version of the Funding Opportunity Webinar, Buildings University Innovators and Leaders Development -- BUILD, presented in November 2014.

89

SciTech Connect: Sunnyvale Marine Climate Deep Retrofit  

Office of Scientific and Technical Information (OSTI)

AND UTILIZATION RESIDENTIAL; RESIDENTIAL BUILDINGS; ARBI; BUILDING AMERICA; MARINE CLIMATE; RETROFIT; PASSIVE HOUSE; HVAC; MONITORING; INDOOR AIR QUALITY; DEEP RETROFIT; Buildings...

90

A Bin Method for Calculating Energy Conservation Retrofit Savings in Commercial Buildings  

E-Print Network [OSTI]

The calculation of measured energy savings from energy conservation retrofits is an important step in the verification of the success of a retrofit (Claridge et al. 1992). Several methods for calculating the savings from energy conservation...

Thamilseran, S.; Haberl, J. S.

1994-01-01T23:59:59.000Z

91

New test procedure evaluates quality and accuracy of energy analysis tools for the residential building retrofit market.  

E-Print Network [OSTI]

New test procedure evaluates quality and accuracy of energy analysis tools for the residential that calculate optimal packages of efficiency measures. To improve the accuracy of energy analysis building retrofit market. Reducing the energy use of existing homes in the United States offers significant

92

Evaluation of energy savings related to building envelope retrofit techniques and ventilation strategies for low energy cooling in  

E-Print Network [OSTI]

Evaluation of energy savings related to building envelope retrofit techniques and ventilation strategies for low energy cooling in offices and commercial sector Laurent Grignon-Massé, Dominique Marchio-use Efficiency Research Group Abstract The energy savings achievable in the end-use space cooling depend

Paris-Sud XI, Université de

93

Review of Prior Commercial Building Energy Efficiency Retrofit Evaluation: A Report to Snohomish Public Utilities District  

SciTech Connect (OSTI)

Snohomish County Public Utilities District (the District or Snohomish PUD) provides electricity to about 325,000 customers in Snohomish County, Washington. The District has an incentive programs to encourage commercial customers to improve energy efficiency: the District partially reimburses the cost of approved retrofits if they provide a level of energy performance improvement that is specified by contract. In 2013 the District contracted with Lawrence Berkeley National Laboratory to provide a third-party review of the Monitoring and Verification (M&V) practices the District uses to evaluate whether companies are meeting their contractual obligations. This work helps LBNL understand the challenges faced by real-world practitioners of M&V of energy savings, and builds on a body of related work such as Price et al. (2013). The District selected a typical project for which they had already performed an evaluation. The present report includes the District's original evaluation as well as LBNL's review of their approach. The review is based on the document itself; on investigation of the load data and outdoor air temperature data from the building evaluated in the document; and on phone discussions with Bill Harris of the Snohomish County Public Utilities District. We will call the building studied in the document the subject building, the original Snohomish PUD report will be referred to as the Evaluation, and this discussion by LBNL is called the Review.

Price, Phillip

2014-12-22T23:59:59.000Z

94

Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring  

SciTech Connect (OSTI)

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of the heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.

Dentz, J.; Henderson, H.; Varshney, K.

2014-09-01T23:59:59.000Z

95

Building America Best Practices Series, Volume 10: Retrofit Techniques and Technologies: Air Sealing  

SciTech Connect (OSTI)

This report was prepared by PNNL for the U.S. Department of Energy Building America Program. The report provides information to home owners who want to make their existing homes more energy efficient by sealing leaks in the building envelope (ceiling, walls, and floors) that let in drafts and let conditioned air escape. The report provides descriptions of 19 key areas of the home where air sealing can improve home performance and energy efficiency. The report includes suggestions on how to find a qualified weatherization or home performance contractor, what to expect in a home energy audit, opportune times for performing air sealing, and what safety and health concerns to be aware of. The report describes some basic building science concepts and topics related to air sealing including ventilation, diagnostic tools, and code requirements. The report will be available for free download from the DOE Building America website. It is a suitable consumer education tool for home performance and weatherization contractors to share with customers to describe the process and value of home energy retrofits.

Baechler, Michael C.; Gilbride, Theresa L.; Hefty, Marye G.; Cole, Pamala C.; Williamson, Jennifer L.; Love, Pat M.

2010-04-12T23:59:59.000Z

96

Funding Opportunity Webinar - Building America | Department of...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

to 4:00PM EST Register for the webinar The Building Technologies Office (BTO)'s Residential Buildings Integration Program has announced the availability of up to 4 million in...

97

SciTech Connect: Analysis of Pre-Retrofit Building and Utility...  

Office of Scientific and Technical Information (OSTI)

and Utility Data IBACOS analyzed pre-retrofit daily utility data to sort homes by energy consumption, allowing for better targeting of homes for physical audits. Following...

98

Retrofitting Vegas: Implementing Energy Efficiency in Two Las Vegas Test Homes  

SciTech Connect (OSTI)

In 2009, the state of Nevada received nearly forty million dollars in Neighborhood Stabilization Funds from the Department of Housing and Urban Development. The purpose of this funding was to stabilize communities that have suffered from foreclosures and abandonment. In an effort to provide guidance to local officials and maximize how effectively this NSP funding is utilized in retrofitting homes, CARB provided design specifications, energy modeling, and technical support for the Building America Retrofit Alliance (BARA) team and its local partners - Better Building Performance, Nevada Energy Star Partners Green Alliance, and Home Free Nevada - for two retrofit test homes. One home was to demonstrate a modest retrofit and the other a deep energy retrofit. Through this project, CARB has provided two robust solution packages for retrofitting homes built in this region between the 1980s and early 1990s without substantially inconveniencing the occupants. The two test homes, the Carmen and Sierra Hills, demonstrate how cost-effectively energy efficient upgrades can be implemented in the hot, dry climate of the Southwest. In addition, the homes were used as an educational experience for home performance professionals, building trades, remodelers, and the general public. In-field trainings on air-sealing, HVAC upgrades, and insulating were provided to local contractors during the retrofit and BARA documented these retrofits through a series of video presentations, beginning with a site survey and concluding with the finished remodel and test out.

Puttagunta, S.

2013-04-01T23:59:59.000Z

99

Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings  

Broader source: Energy.gov [DOE]

The webinar focused on improving the performance of central space conditioning systems in multifamily buildings, including hydronic heating strategies and the evaluation of thermostatically controlled radiator valves (TRVs).

100

Building Retrofits: Energy Conservation and Employee Retention Considerations in Medium-Size Commercial Buildings  

E-Print Network [OSTI]

of Environmental Economics and Management, Lighting Design and Application, Academy of Management Executive, Artificial Intelligence Review, Indoor Built Environment, Journal of Corporate Real Estate, Science, Indoor Air, and Healthy Buildings, Journal of Real..., Science, Indoor Air, Healthy Buildings, Journal of Real Estate Research, Journal of Property Investment and Finance, Journal of Sustainable Real Estate. Reputable Organizations Rocky Mountain Institute, Environmental Protection Agency (EPA), Energy...

Freeman, Janice

2013-04-29T23:59:59.000Z

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

The USDOE Forrestal Building Lighting Retrofit: Preliminary Analysis of Electricity Savings  

E-Print Network [OSTI]

In September of 1993 a 36,832 fixture lighting retrofit was completed at the United States Department of Energy Forrestal complex in Washington, D.C. This retrofit represents DOE's largest project to date that utilizes a Shared Energy Savings (SES...

Haberl, J. S.; Bou-Saada, T. E.; Vajda, E. J.; Shincovich, M.; D'Angelo III, L.; Harris, L.

1994-01-01T23:59:59.000Z

102

Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings  

Broader source: Energy.gov [DOE]

This webinar will focus on improving the performance of central space conditioning systems in multifamily buildings. Presenters will discuss hydronic heating strategies and the evaluation of thermostatically controlled radiator valves (TRVs).

103

Cost Savings and Energy Reduction: Bi-Level Lighting Retrofits in Multifamily Buildings  

E-Print Network [OSTI]

Community Environmental Center implements Bi- Level Lighting fixtures as a component of cost-effective multifamily retrofits. These systems achieve substantial energy savings by automatically reducing lighting levels when common areas are unoccupied...

Ackley, J.

2010-01-01T23:59:59.000Z

104

Building America Webinar: Low-E Storms: The Next Big Thing in Window Retrofits  

Broader source: Energy.gov [DOE]

Until recently, energy-efficient window retrofit options have largely been limited to repair or replacement; leaving the homeowner to decide between affordability and deeper energy savings.  A new...

105

Apply: Funding Opportunity- Buildings University Innovators and Leaders Development (BUILD)  

Broader source: Energy.gov [DOE]

Full Application Deadline – February 11, 2015 This FOA makes available competitive, 2-year cooperative agreements for U.S.-based university teams to research and develop innovative building energy efficient technologies, manufacturing (for projects developing hardware), and commercialization.

106

Bay Ridge Gardens - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit: Annapolis, Maryland. Building America Case Study: Whole-House Solutions for Existing Homes (Fact Sheet)  

SciTech Connect (OSTI)

Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place DER at the Bay Ridge multifamily (MF) development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a "base scope" retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a "DER scope" which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. The base scope was applied to the entire apartment complex, except for one 12-unit building which underwent the DER scope. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

Not Available

2013-10-01T23:59:59.000Z

107

USER SATISFACTION WITH INNOVATIVE COOLING RETROFITS IN SACRAMENTO PUBLIC HOUSING  

E-Print Network [OSTI]

and a housing authority have been retrofitting their buildings with evaporative coolers, ground-source heatpumps

Diamond, Richard

108

Data and Analytics to Inform Energy Retrofit of High Performance Buildings  

E-Print Network [OSTI]

commissioning new and existing commercial buildings: Lessonsfrom 224 buildings. ProceedingsNational Conference on Building Commissioning. [5]. CABA.

Hong Ph.D., Tianzhen

2014-01-01T23:59:59.000Z

109

Simulation of the Post-Retrofit Thermal Energy Use for the University Teaching Center (UTC) Building with the Use of Simplified System Models  

E-Print Network [OSTI]

ESL-TR-91/12-03 ENERGY SYSTEMS LABORATORY TECHNICAL REPORT REPRINTED WITH PERMISSION Simulation of the Post-Retrofit Thermal Energy Use for the University Teaching Center (UTC) Building with the Use of Simplified System Models Srinivas Katipamula, P.... Texas 77843 (409) 845-6402. or (409) 845-3251 INTRODUCTION Several state owned buildings with dual-duct constant volume (DDCV) systems have been retrofitted with energy efficient variable air volume systems (VAV) as part of the Texas LoanSTAR Program...

Katipamula, S.; Claridge, D. E.

1991-01-01T23:59:59.000Z

110

Wyandotte Neighborhood Stabilization Program: Retrofit of Two Homes  

SciTech Connect (OSTI)

The Wyandotte NSP2 project aims to build 20 new houses and retrofit 20 existing houses in Wyandotte, MI. This report will detail the retrofit of 2 existing houses in the program. Wyandotte is part of a Michigan State Housing Development Authority-led consortium that is funded by HUD under the NSP2 program. The City of Wyandotte has also been awarded DOE EE&CBG funds that are being used to develop a district GSHP system to service the project. This draft report examines the energy efficiency recommendations for retrofit construction at these homes. The report will be of interest to anyone planning an affordable, high performance retrofit of an existing home in a Cold Climate zone. Information from this report will also be useful to retrofit or weatherization program staff as some of the proposed retrofit solutions will apply to a wide range of projects. Preliminary results from the first complete house suggest that the technology package employed (which includes spray foam insulation and insulating sheathing) does meet the specific whole house water, air, and thermal control requirements, as well as, the project's affordability goals. Monitoring of the GSHP system has been recommended and analysis of this information is not yet available.

Lukachko, A.; Grin, A.; Bergey, D.

2013-04-01T23:59:59.000Z

111

Evaluation of Retrofit Delivery Packages  

SciTech Connect (OSTI)

Residential energy retrofit activities are a critical component of efforts to increase energy efficiency in the U.S. building stock; however, retrofits account for a small percentage of aggregate energy savings at relatively high per unit costs. This report by Building America research team, Alliance for Residential Building Innovation (ARBI), describes barriers to widespread retrofits and evaluates opportunities to improve delivery of home retrofit measures by identifying economies of scale in marketing, energy assessments, and bulk purchasing through pilot programs in portions of Sonoma, Los Angeles, and San Joaquin Counties, CA. These targeted communities show potential and have revealed key strategies for program design, as outlined in the report.

Berman, M.; Smith, P.; Porse, E.

2013-07-01T23:59:59.000Z

112

Multifamily Ventilation Retrofit Strategies  

SciTech Connect (OSTI)

In multifamily buildings, central ventilation systems often have poor performance, overventilating some portions of the building (causing excess energy use), while simultaneously underventilating other portions (causing diminished indoor air quality). BSC and Innova Services Corporation performed a series of field tests at a mid-rise test building undergoing a major energy audit and retrofit, which included ventilation system upgrades.

Ueno, K.; Lstiburek, J.; Bergey, D.

2012-12-01T23:59:59.000Z

113

Text-Alternative Version of Building America Webinar: Low-e Storms: The Next "Big Thing" in Window Retrofits  

Broader source: Energy.gov [DOE]

Low-e Storms:  The Next “Big Thing” in Window RetrofitsOfficial Webinar Transcript (September 9, 2014)

114

Scenario analysis of retrofit strategies for reducing energy consumption in Norwegian office buildings  

E-Print Network [OSTI]

Model buildings were created for simulation to describe typical office buildings from different construction periods. A simulation program was written to predict the annual energy consumption of the buildings in their ...

Engblom, Lisa A. (Lisa Allison)

2006-01-01T23:59:59.000Z

115

New Funding Alternatives, Sources and Strategies To Create High-Performing, Energy Efficient Buildings  

E-Print Network [OSTI]

MM ? 10 year contract term ? $5 per square foot of hard cost invested for improvements ? $1 per square foot in energy savings created on average Distributed Energy Generation Systems (DEGS) ? Characteristics ? Small scale power generation... Lease Purchase Agreements ? Enables you to acquire essential-use assets, including energy efficiency retrofits and upgrades. ? A tax-exempt municipal lease, the government entity MAY have a ?non appropriation of funds? clause in the agreement...

Flores, M.

2012-01-01T23:59:59.000Z

116

HOLDSWORTH RETROFIT AND RENOVATION  

E-Print Network [OSTI]

IPCC report, the buildings sector has more potential to contribute to climate change mitigation thanHOLDSWORTH RETROFIT AND RENOVATION GREEN BUILDING COMMITTEE ENVIRONMENTAL PERFORMANCE ADVISORY Holdsworth Hall Shower and Bicycle Commuting 20 Behavioral Change /Green Office Program 22 ENERGY CONSUMPTION

Schweik, Charles M.

117

The design and retrofit of buildings for resistance to blast-induced progressive collapse  

E-Print Network [OSTI]

In recent years, concern has risen drastically regarding the suitability of structural design for blast resistance. Historic events have proven that buildings that are designed in compliance with conventional building codes ...

Abbott Galvão Sobreira Lopes, Isabel

2009-01-01T23:59:59.000Z

118

Building America Whole-House Solutions for Existing Homes: Group Home Energy Efficiency Retrofit for 30% Energy Savings (Fact Sheet)  

Broader source: Energy.gov [DOE]

This project studies the specification, implementation, and energy savings from an energy efficiency retrofit in a group home, with an energy savings goal of 30%.

119

Funding Opportunity Webinar – Building America Industry Partnerships for High Performance Housing Innovations  

Broader source: Energy.gov [DOE]

This webinar provides an overview of the “Building America Industry Partnerships for High Performance Housing Innovations” Funding Opportunity Announcement, DE-FOA-0001117.

120

Funding Opportunity Webinar – Building America Industry Partnerships for High Performance Housing Innovations (Text Version)  

Broader source: Energy.gov [DOE]

Below is the text version of the Funding Opportunity Webinar, Building America Industry Partnerships for High Performance Housing Innovations, presented in November 2014.

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Funding Opportunity Announcement State Energy Program (SEP) Strengthening Building Retrofit Markets and Stimulating Energy Efficiency Action  

Broader source: Energy.gov [DOE]

The Department of Energy (DOE) National Energy Technology Laboratory (NETL), on behalf of the Office of Energy Efficiency and Renewable Energys (EEREs) State Energy Program (SEP), is seeking applications to advance policies, programs, and market strategies that accelerate job creation and reduce energy bills while achieving energy and climate security for the nation.

122

Bright prospects for lighting retrofits  

SciTech Connect (OSTI)

Great potential for energy savings can be found in the alleys, hallways and stairwells of multifamily buildings, but this potential is not always easy to realize. This article discusses the solution to common problems, retrofitting mistakes, retrofitting for savings, replacements for incandescent bulbs, better exit lights. 1 fig., 1 tab.

Hasterok, L. [Wisconsin Energy Conservation Corp., Madison, WI (United States)

1995-09-01T23:59:59.000Z

123

Study of Multifamily Energy Retrofit Using Flexible Multizone Building Simulation Model  

Broader source: Energy.gov [DOE]

This presentation was delivered at the U.S. Department of Energy Building America Technical Update meeting on April 29-30, 2013, in Denver, Colorado.

124

Strategy Guideline: Mitigation of Retrofit Risk Factors  

SciTech Connect (OSTI)

The Alliance for Residential Building Innovation (ARBI) is currently developing strategies designed to promote and achieve increased energy savings and promote upgrades in the residential retrofit sector. These strategies are targeted to retrofit program managers, retrofit contractors, policy makers, academic researchers, and non-governmental organizations. This report focuses on four key areas to promote home energy upgrades: fostering accurate energy savings projections; understanding consumer perceptions for energy savings; measuring energy savings, and ensuring quality control for retrofit installations.

Berman, M.; Smith, P.; Porse, E.

2012-12-01T23:59:59.000Z

125

Financing Energy Efficiency Retrofits in the Commercial Sector Webinar  

Broader source: Energy.gov [DOE]

Financing Energy Efficiency Retrofits in the Commercial Sector Webinar, from the U.S. Department of Energy's Better Buildings program.

126

Funding Opportunity Webinar- Advancing Solutions To Improve the Energy Efficiency of US Commercial Buildings  

Broader source: Energy.gov [DOE]

This webinar provides an overview of the DOE Funding Opportunity Announcement DE-FOA-0001168, "Advancing Solutions to Improve the Energy Efficiency of U.S. Commercial Buildings," which seeks to fund the scale-up of promising solutions to the market barriers that hinder the growth of energy efficiency in the commercial building sector.

127

Assessment of Solar Energy Conversion Technologies-Application of Thermoelectric Devices in Retrofit an Office Building  

E-Print Network [OSTI]

Thermo electric (TE) devices offer an opportunity to introduce renewable energy into existing and new buildings. TE devices harvest energy from the temperature differential between the hot and cold side of a semiconductor material. In this study...

Azarbayjani, M.; Anderson, J.

128

Retrofit Options for Increasing Energy Efficiency in Office Buildings- Methodology Review  

E-Print Network [OSTI]

Portuguese Buildings represent 35% of primary energy consumption in 2006, with non-residential sector representing almost half of this number globally and around 65% in Lisbon city. Expected to grow 5% yearly in this period, non...

Pereira, N. C.

129

Improvements to building energy usage modeling during early design stages and retrofits  

E-Print Network [OSTI]

A variety of improvements to the MIT Design Advisor, a whole-building energy usage modeling tool intended for use during early design stages, are investigated. These include changes to the thermal mass temperature distribution ...

Mandelbaum, Andrew (Andrew Joseph)

2014-01-01T23:59:59.000Z

130

Building America Webinar: Low-E Storms: The Next Big Thing in Window Retrofits  

Broader source: Energy.gov [DOE]

This Building America webinar presented a new and improved low-e storm window that boasts a combination of curb appeal and energy efficiency, all for a fraction of the cost of window replacement, on Sept. 9, 2014.

131

Energy Engineering Analysis Program (EEAP), Fort Bliss headquarters building, lighting retrofit, Fort Bliss, El Paso, Texas  

SciTech Connect (OSTI)

The purpose of this study is to analyze the use of high efficiency fluorescent lighting with energy efficient lamps and electronic ballast for the Headquarters Building (Bldg. number 2) at Fort Bliss.

NONE

1993-02-01T23:59:59.000Z

132

Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring  

SciTech Connect (OSTI)

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. of Cambridge, Massachusetts, to implement and study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating control systems in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded.

Dentz, J.; Henderson, H.; Varshney, K.

2013-10-01T23:59:59.000Z

133

The cost-effectiveness of retrofitting sanitary fixtures in restrooms of a university building  

E-Print Network [OSTI]

Architecture building A at Texas A&M University. The researcher directly measured the actual water-volume per flush of as-is, tune-up, low-consumption manual, and low-consumption automatic water closets and urinals. The data collected by these observations...

Hwang, Byoung Hoon

2004-09-30T23:59:59.000Z

134

Bridging the Gap Between Commissioning Measures and Large Scale Retrofits in Existing Buildings  

E-Print Network [OSTI]

to the systems installed in the building to reach the same goal. The purpose of the investigations presented here is to find energy-saving measures which economically fall between the retro-commissioning measures which typically have very short paybacks...

Bynum, J.; Jones, A.; Claridge, D.E.

2011-01-01T23:59:59.000Z

135

Bridging the Gap Between Commissioning Measures and Large Scale Retrofits in Existing Buildings  

E-Print Network [OSTI]

installed in the building to reach the same goal. The purpose of the investigations presented here is to find energy-saving measures which economically fall between the retro-commissioning measures which typically have very short paybacks and the large scale...

Bynum, J.; Jones, A.; Claridge, D. E.

136

Retrofit California Overview and Final Reports  

SciTech Connect (OSTI)

Energy efficiency retrofits (also called upgrades) are widely recognized as a critical component to achieving energy savings in the building sector to help lower greenhouse gas (GHG) emissions. To date, however, upgrades have accounted for only a small percentage of aggregate energy savings in building stock, both in California and nationally. Although the measures and technologies to retrofit a building to become energy efficient are readily deployed, establishing this model as a standard practice remains elusive. Retrofit California sought to develop and test new program models to increase participation in the energy upgrade market in California. The Program encompassed 24 pilot projects, conducted between 2010 and mid-2013 and funded through a $30 million American Recovery and Reinvestment Act (ARRA) grant from the U.S. Department of Energy’s (DOE) Better Buildings Neighborhood Program (BBNP). The broad scope of the Program can be seen in the involvement of the following regionally based Grant Partners: Los Angeles County (as prime grantee); Association of Bay Area Governments (ABAG), consisting of: o StopWaste.org for Alameda County o Regional Climate Protection Authority (RCPA) for Sonoma County o SF Environment for the City and County of San Francisco o City of San Jose; California Center for Sustainable Energy (CCSE) for the San Diego region; Sacramento Municipal Utilities District (SMUD). Within these jurisdictions, nine different types of pilots were tested with the common goal of identifying, informing, and educating the people most likely to undertake energy upgrades (both homeowners and contractors), and to provide them with incentives and resources to facilitate the process. Despite its limited duration, Retrofit California undoubtedly succeeded in increasing awareness and education among home and property owners, as well as contractors, realtors, and community leaders. However, program results indicate that a longer timeframe will be needed to transform the market and establish energy retrofits as the new paradigm. Innovations such as Flex Path, which came about because of barriers encountered during the Program, have already shown promise and are enabling increased participation. Together, the pilots represent an unprecedented effort to identify and address market barriers to energy efficiency upgrades and to provide lessons learned to shape future program planning and implementation. The statistics reflects the scope of the marketing and outreach campaigns, which tested a variety of approaches to increase understanding of the benefits of energy upgrades to drive participation in the Program. More traditional methods such as TV and radio advertisements were complimented by innovative community based social marketing campaigns that sought to leverage the trusted status of neighborhood organizations and leaders in order to motivate their constituents to undertake retrofits. The remainder of this report provides an overview of Retrofit California including brief summaries of the pilots’ main components and highlights, followed by the major findings or takeaway lessons from the approaches that were tested. Eleven of the pilots will be continued, with modifications, under the ratepayer-funded Regional Energy Networks. Involvement in the RENS by many of the Retrofit California partners will ensure that early lessons learned are carried forward to guide future programs for energy upgrades in California.

Choy, Howard; Rosales, Ana

2014-03-01T23:59:59.000Z

137

Rehabilitating missing energy use and weather data when determining retrofit energy savings in commercial buildings  

E-Print Network [OSTI]

/Exponential Model. . . . . . . . . . . . . . . 18 2. 2. 2 Method Used to Fill Gaps in the Test Meteorological Year 2 Dataset. 19 2. 2. 2. 1 A Description of TMY Dataset and TMY2s Dataset. . . . . . . . . . . . . 19 2. 2. 2. 2 Data-Fifiing Methods. 19 2. 2. 3... . . . xvn NOMENCLATURE. CHAPTER . XX1 I INTRODUCTION. 1. 1 Motivation. 1. 2 Objective and Purpose . . . 1 . . . 3 II LITERATURE REVIEW . 2. 1 Approaches for Modeling Weather Data and Building Energy Data Sequences. 4 2. 1. 1 Calibrated...

Chen, Hui

1999-01-01T23:59:59.000Z

138

Hydronic Heating Retrofits for Low-Rise Multifamily Buildings - Phase 1: Boiler Control Replacement and Monitoring  

SciTech Connect (OSTI)

The ARIES Collaborative, a Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, MA to implement and study improvements to the heating system in one of the non-profit's housing developments. The heating control systems in the 42-unit Columbia CAST housing development were upgraded in an effort projected to reduce heating costs by 15 to 25 percent.

Dentz, J.; Henderson, H.

2012-04-01T23:59:59.000Z

139

Energy Efficiency in Commercial Buildings: Experiences and Results from the German funding Program SolarBau  

E-Print Network [OSTI]

University Karlsruhe (TH) - Department of Architecture Building Physics and Technical Building Services Energy Efficiency inCommercial Buildings Experiences and Results from theGerman funding Program SolarBau S. Herkel, G. L?hnert, K. Voss, A... comfort range? Energy use oflean officebuildings University Karlsruhe (TH) - Department of Architecture Building Physics and Technical Building Services Targets ofSolarBau End- bzw. Prim?renergie in kWh/m?a 050100150200250300 Beleuchtung Klimatisierung L...

Herkel, S.; Lohnert, G.; Voss, K.; Wagner, A.

2004-01-01T23:59:59.000Z

140

Deep Residential Retrofits in East Tennessee  

SciTech Connect (OSTI)

Executive Summary Oak Ridge National Laboratory (ORNL) is furthering residential energy retrofit research in the mixed-humid climate of East Tennessee by selecting 10 homes and guiding the homeowners in the energy retrofit process. The homeowners pay for the retrofits, and ORNL advises which retrofits to complete and collects post-retrofit data. This effort is in accordance with the Department of Energy s Building America program research goal of demonstrating market-ready energy retrofit packages that reduce home energy use by 30 50%. Through this research, ORNL researchers hope to understand why homeowners decide to partake in energy retrofits, the payback of home energy retrofits, and which retrofit packages most economically reduce energy use. Homeowner interviews help the researchers understand the homeowners experience. Information gathered during the interviews will aid in extending market penetration of home energy retrofits by helping researchers and the retrofit industry understand what drives homeowners in making positive decisions regarding these retrofits. This report summarizes the selection process, the pre-retrofit condition, the recommended retrofits, the actual cost of the retrofits (when available), and an estimated energy savings of the retrofit package using EnergyGauge . Of the 10 households selected to participate in the study, only five completed the recommended retrofits, three completed at least one but no more than three of the recommended retrofits, and two households did not complete any of the recommended retrofits. In the case of the two homes that did none of the recommended work, the pre-retrofit condition of the homes and the recommended retrofits are reported. The five homes that completed the recommended retrofits are monitored for energy consumption of the whole house, appliances, space conditioning equipment, water heater, and most of the other circuits with miscellaneous electric loads (MELs) and lighting. Thermal comfort is also monitored, with temperature and humidity measured in all conditioned zones, attics, crawlspaces, and unconditioned basements. In some homes, heat flux transducers are installed on the basement walls to help determine the insulating qualities of the technologies and practices. EnergyGauge is used to estimate the pre-retrofit and post-retrofit home energy rating system (HERS) index and reduction in energy consumption and energy bill. In a follow-up report, data from the installed sensors will be presented and analyzed as well as a comparison of the post-retrofit energy consumption of the home to the EnergyGauge model of the post-retrofit home. Table ES1 shows the retrofits that were completed at the eight households where some or all of the recommended retrofits were completed. Home aliases are used to keep the homeowners anonymous. Some key findings of this study thus far are listed as follows. Some homeowners (50%) are not willing to spend the money to reach 30 50% energy savings. Quality of retrofit work is significantly variable among contractors which impact the potential energy savings of the retrofit. Challenges exist in defining house volume and floor area. Of the five homes that completed all the recommended retrofits, energy bill savings was not the main driver for energy retrofits. In no case were the retrofits cost neutral given a 15 year loan at 7% interest for the retrofit costs.

Boudreaux, Philip R [ORNL; Hendrick, Timothy P [ORNL; Christian, Jeffrey E [ORNL; Jackson, Roderick K [ORNL

2012-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Apply: Funding Opportunity- Advancing Solutions to Improve Energy Efficiency of Commercial Buildings  

Broader source: Energy.gov [DOE]

Closed Application Deadline: January 20, 2015 The Building Technologies Office (BTO) Commercial Buildings Integration Program has announced the availability of nearly $9 million for Funding Opportunity Announcement (FOA) DE-FOA-0001168, “Advancing Solutions to Improve the Energy Efficiency of U.S. Commercial Buildings

142

Apply: Funding Opportunity- Building America Industry Partnerships for High Performance Housing Innovation  

Broader source: Energy.gov [DOE]

Application Deadline: February 4, 2015 The Building Technologies Office (BTO)’s Residential Buildings Integration Program has announced the availability of up to $4 million in 2015 for the Building America Industry Partnerships for High Performance Housing Innovation Funding Opportunity Announcement (FOA) DE-FOA-0001117.

143

Better Buildings Webinar: Making Utility Energy Efficiency Funds...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

of Energy's Better Buildings will host a webinar on innovative collaborations with utilities to bring big energy savings to their building portfolios and help reduce utility...

144

Building America Efficient Solutions for Existing Homes Case Study: Retrofit of 1915 Home, Dayton, Washington  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd: ScopeDepartment1,EnergyDescription Building

145

Evaluation of Two CEDA Weatherization Pilot Implementations of an Exterior Insulation and Over-Clad Retrofit Strategy for Residential Masonry Buildings in Chicago  

SciTech Connect (OSTI)

This project examines the implementation of an exterior insulation and over-clad strategy for brick masonry buildings in Chicago. The strategy was implemented at a free-standing two story two-family dwelling and a larger free-standing multifamily building. The test homes selected for this research represent predominant housing types for the Chicago area. High heating energy use typical in these buildings threaten housing affordability. Uninsulated mass masonry wall assemblies also have a strongly detrimental impact on comfort. Significant changes to the performance of masonry wall assemblies is generally beyond the reach of typical weatherization (Wx) program resources. The Community and Economic Development Association of Cook County, Inc. (CEDA) has secured a Sustainable Energy Resources for Consumers (SERC) innovation grant sponsored by the United States Department of Energy (DOE). This grant provides CEDA the opportunity to pursue a pilot implementation of innovative approaches to retrofit in masonry wall enclosures. The exterior insulation and over-clad strategy implemented through this project was designed to allow implementation by contractors active in CEDA weatherization programs and using materials and methods familiar to these contractors. The retrofit measures are evaluated in terms of feasibility, cost and performance. Through observations of the strategies implemented, the research described in this report identifies measures critical to performance as well as conditions for wider adoption. The research also identifies common factors that must be considered in determining whether the exterior insulation and over-clad strategy is appropriate for the building.

Neuhauser, K.

2013-08-01T23:59:59.000Z

146

Building America Whole-House Solutions for Existing Homes: Evaluation...  

Energy Savers [EERE]

Ordinance. Evaluation of a Multifamily Retrofit in Climate Zone 5 - Boulder, Colorado More Documents & Publications Building America Expert Meeting: Retrofit...

147

Results from Development of Model Specifications for Multifamily Energy Retrofits  

SciTech Connect (OSTI)

Specifications, modeled after CSI MasterFormat, provide the trade contractors and builders with requirements and recommendations on specific building materials, components and industry practices that comply with the expectations and intent of the requirements within the various funding programs associated with a project. The goal is to create a greater level of consistency in execution of energy efficiency retrofits measures across the multiple regions a developer may work. IBACOS and Mercy Housing developed sample model specifications based on a common building construction type that Mercy Housing encounters.

Brozyna, K.

2012-08-01T23:59:59.000Z

148

Sunnyvale Marine Climate Deep Retrofit  

SciTech Connect (OSTI)

The Alliance for Residential Building Innovation (ARBI) and Allen Gilliland of One Sky Homes collaborated on a marine climate retrofit project designed to meet both Passive House (PH) and Building America (BA) program standards. The scope included sealing, installing wall, roof and floor insulation (previously lacking), replacing windows, upgrading the heating and cooling system, and installing.

German, A.; Siddiqui, A.; Dakin, B.

2014-11-01T23:59:59.000Z

149

Measuring energy-saving retrofits: Experiences from the Texas LoanSTAR program  

SciTech Connect (OSTI)

In 1988 the Governor`s Energy Management Center of Texas received approval from the US Department of Energy to establish a $98.6 million state-wide retrofit demonstration revolving loan program to fund energy-conserving retrofits in state, public school, and local government buildings. As part of this program, a first-of-its-kind, statewide Monitoring and Analysis Program (MAP) was established to verify energy and dollar savings of the retrofits, reduce energy costs by identifying operational and maintenance improvements, improve retrofit selection in future rounds of the LoanSTAR program, and initiate a data base of energy use in institutional and commercial buildings located in Texas. This report discusses the LoanSTAR MAP with an emphasis on the process of acquiring and analyzing data to measure savings from energy conservation retrofits when budgets are a constraint. This report includes a discussion of the program structure, basic measurement techniques, data archiving and handling, data reporting and analysis, and includes selected examples from LoanSTAR agencies. A summary of the program results for the first two years of monitoring is also included.

Haberl, J.S.; Reddy, T.A.; Claridge, D.E.; Turner, W.D.; O`Neal, D.L.; Heffington, W.M. [Texas A and M Univ., College Station, TX (United States). Energy Systems Lab.] [Texas A and M Univ., College Station, TX (United States). Energy Systems Lab.

1996-02-01T23:59:59.000Z

150

Building Technologies Program - Funding Profile by Subprogram | Department  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 < prev nextInvestigationofBuilding Technologiesof

151

International Energy Agency Implementing Agreements and Annexes: A Guide for Building Technologies Program Managers  

E-Print Network [OSTI]

Measures for Government Building Retrofits" Develop “Best Practice Guidelines Measures for Government Building Retrofits" Develop “Best Practice Guidelines Measures for Government Building Retrofits" Develop “Best Practice Guidelines 

Evans, Meredydd

2008-01-01T23:59:59.000Z

152

Application and Mode Establishment of Asset-backed Securitization in Existing Large-scale Public Building Retrofit Financing in China  

E-Print Network [OSTI]

Statistical data for 2005 show that electrical consumption of large-scale public buildings occupying 5 percent of total residential construction area equals 50 percent of the total residential electrical consumption in Beijing. It is necessary...

Sun, J.; Wu, Y.; Dai, Z.; Hao, Y.

2006-01-01T23:59:59.000Z

153

Phase A: Initial Development of an Advanced Diagnostic Procedure for Air-Side Retrofits in Commercial Buildings  

E-Print Network [OSTI]

of Buildings Energy Research at the United States Department of Energy (DOE) through the Existing Buildings Efficiency Research Program at Oak Ridge National Laboratory (ORNL). Neither the ESL, TEES, DOE, or ORNL, or any of their employees, makes any warranty.... Reference herein to any specific commercial product, process, or service by tradename, trademark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement, recommendation, or favoring by the ESL, TEES, DOE, ORNL, or any agency...

Reddy, T. A.; Kissock, J. K.; Katipamula, S.; Claridge, D. E.

1994-01-01T23:59:59.000Z

154

Applications of sustainable technology to retrofits in urban areas  

E-Print Network [OSTI]

Energy Losses from old buildings comprise a significant percentage of the total residential energy consumption in the United States. Retrofitting buildings for conservation can greatly decrease the present energy demand ...

Taylor, Paki (Paki A.), 1974-

2001-01-01T23:59:59.000Z

155

Deep Energy Retrofits: A Southwestern Case Study  

E-Print Network [OSTI]

to a carbon-neutral environment, but we can remodel our way there. Over the course of seven years, green-buildingDeep Energy Retrofits: A Southwestern Case Study Heading Toward Net Zero Thursday, December 2, 2010 ASU Project Manager, Energize Phoenix Greg L. Brown Principal, Ecosense, LLC We cannot build our way

Zhang, Junshan

156

Building America Whole-House Solutions for Existing Homes: National...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet) Building America Whole-House Solutions for Existing Homes: National Grid Deep Energy Retrofit...

157

Building America Technology Solutions for New and Existing Homes...  

Energy Savers [EERE]

Stand-off Furring in Deep Energy Retrofits Building America Technology Solutions for New and Existing Homes: Stand-off Furring in Deep Energy Retrofits This research project,...

158

Technical Assistance Project (TAP) Revolving Loan Funds: Basics...  

Broader source: Energy.gov (indexed) [DOE]

(cont.) Eligible Retrofit Projects (cont.) Building Shell Improvements (insulation, window film) Water Conservation Projects Systems Commissioning Three types of...

159

A Path to Successful Energy Retrofits: Early Collaboration through Integrated  

E-Print Network [OSTI]

and designers. It outlines the value of forming an integrated project delivery team and developing a complete process for designing an energy retrofit for a building. Instead, it focuses on the early design retrofits require integrated project delivery teams, this guide presents an integrated design process

160

Deep Energy Retrofits - Eleven California Case Studies  

E-Print Network [OSTI]

retrofit thermal leakage in guestroom ceiling…………………………….171retrofit thermal leakage in guestroom ceiling Figure 107 -

Less, Brennan

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

New Hampshire Better Buildings - Final Interim Report  

SciTech Connect (OSTI)

With $10 million in funding from the U.S. Department of Energy's (DOE) Better Buildings Neighborhood Program, the NH Better Buildings program was established as an initiative that initially empowered the three “Beacon Communities” of Berlin, Nashua and Plymouth to achieve transformative energy savings and reductions in fossil fuel use and greenhouse gases through deep energy retrofits and complementary sustainable energy solutions. The program also enabled those Communities to provide leadership to other communities around the state as “beacons” of energy efficiency. The goal of the program was to reduce energy use by a minimum of 15% through energy efficiency upgrades in residential and commercial buildings in the communities. The program expanded statewide in April 2012 by issuing a competitive solicitation for additional commercial projects non-profit, and municipal energy efficiency projects from any community in the state, and a partnership with the state’s utility-run, ratepayer-funded residential Home Performance with ENERGY STAR® (HPwES) program. The NH Better Buildings program was administered by the New Hampshire Office of Energy and Planning (OEP) and managed by the NH Community Development Finance Authority (CDFA). The program started in July 2010 and the last projects funded with American Reinvestment and Recovery Act (ARRA) funds were completed in August 2013. The program will continue after the American Recovery and Reinvestment Act program period as a Revolving Loan Fund, enabling low-interest financing for deep energy retrofits into the future.

Cramton, Karen [NH Office of Energy and Planning] [NH Office of Energy and Planning; Peters, Katherine

2014-02-20T23:59:59.000Z

162

New Hampshire Better Buildings - Final Report  

SciTech Connect (OSTI)

With $10 million in funding from the U.S. Department of Energy's (DOE) Better Buildings Neighborhood Program, the NH Better Buildings program was established as an initiative that initially empowered the three “Beacon Communities” of Berlin, Nashua and Plymouth to achieve transformative energy savings and reductions in fossil fuel use and greenhouse gases through deep energy retrofits and complementary sustainable energy solutions. The program also enabled those Communities to provide leadership to other communities around the state as “beacons” of energy efficiency. The goal of the program was to reduce energy use by a minimum of 15% through energy efficiency upgrades in residential and commercial buildings in the communities. The program expanded statewide in April 2012 by issuing a competitive solicitation for additional commercial projects non-profit, and municipal energy efficiency projects from any community in the state, and a partnership with the state’s utility-run, ratepayer-funded residential Home Performance with ENERGY STAR® (HPwES) program. The NH Better Buildings program was administered by the New Hampshire Office of Energy and Planning (OEP) and managed by the NH Community Development Finance Authority (CDFA). The program started in July 2010 and the last projects funded with American Reinvestment and Recovery Act (ARRA) funds were completed in August 2013. The program will continue after the American Recovery and Reinvestment Act program period as a Revolving Loan Fund, enabling low-interest financing for deep energy retrofits into the future.

Cramton, Karen [NH Office of Energy and Planning; Peters, Katherine

2014-11-01T23:59:59.000Z

163

Building America Webinar: High Performance Space Conditioning...  

Energy Savers [EERE]

Strategies for Affordable Housing Building America Webinar: High Performance Space Conditioning Systems, Part II - Air Distribution Retrofit Strategies for Affordable...

164

Colorado State Capitol Building Geothermal Program  

Broader source: Energy.gov [DOE]

Retrofit a large scale ground source heat pump system into a historic building located in a built up urban area.

165

Advanced Rooftop Control (ARC) Retrofit: Field-Test Results  

SciTech Connect (OSTI)

The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.

Wang, Weimin; Katipamula, Srinivas; Ngo, Hung; Underhill, Ronald M.; Taasevigen, Danny J.; Lutes, Robert G.

2013-07-31T23:59:59.000Z

166

Method for Determining Optimal Residential Energy Efficiency Retrofit Packages  

SciTech Connect (OSTI)

Businesses, government agencies, consumers, policy makers, and utilities currently have limited access to occupant-, building-, and location-specific recommendations for optimal energy retrofit packages, as defined by estimated costs and energy savings. This report describes an analysis method for determining optimal residential energy efficiency retrofit packages and, as an illustrative example, applies the analysis method to a 1960s-era home in eight U.S. cities covering a range of International Energy Conservation Code (IECC) climate regions. The method uses an optimization scheme that considers average energy use (determined from building energy simulations) and equivalent annual cost to recommend optimal retrofit packages specific to the building, occupants, and location. Energy savings and incremental costs are calculated relative to a minimum upgrade reference scenario, which accounts for efficiency upgrades that would occur in the absence of a retrofit because of equipment wear-out and replacement with current minimum standards.

Polly, B.; Gestwick, M.; Bianchi, M.; Anderson, R.; Horowitz, S.; Christensen, C.; Judkoff, R.

2011-04-01T23:59:59.000Z

167

Residential Retrofit Program Design Guide Overview Transcript...  

Broader source: Energy.gov (indexed) [DOE]

Residential Retrofit Program Design Guide Overview Transcript.doc Residential Retrofit Program Design Guide Overview Transcript.doc Residential Retrofit Program Design Guide...

168

Measured energy savings and economics of retrofitting existing single- family homes: An update of the BECA-B database  

SciTech Connect (OSTI)

These appendices are the companion volume to report number LBL--28147 Vol.1, with the same title. The summary data tables include physical characteristics, energy consumption, savings, and the retrofit measures installed and their costs for each retrofit project. Each existing single family residential building'' retrofit project in the BECA-B database is described. 99 refs. (BM)

Cohen, S.D.; Goldman, C.A.; Harris, J.P.

1991-02-01T23:59:59.000Z

169

Expert Meeting Report: Interior Insulation Retrofit of Mass Masonry Wall Assemblies  

SciTech Connect (OSTI)

The Building Science Consortium held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011 at the Westford Regency Hotel in Westford, MA. This report outlines the extensive information that was presented on assessment of risk factors for premature building deterioration due to interior insulation retrofits, and methods to reduce such risks.

Ueno, K.; Van Straaten, R.

2012-02-01T23:59:59.000Z

170

Retrofit Air Preheat Economics  

E-Print Network [OSTI]

Retrofit air preheat systems are the most reliable and efficient means to effect significant energy conservation for large existing industrial furnaces. Units can be quickly installed without a lengthy shutdown, and the furnace efficiency can...

Goolsbee, J. A.

1981-01-01T23:59:59.000Z

171

ADA Retrofit and Construction  

E-Print Network [OSTI]

ADA Retrofit and Construction Management Richfield, MN Breckenridge, MN #12;Introduction & Outline Design vs. Construction § Case Studies § City of Richfield's Transition Plan #12;How Detailed Should, MN #12;Case Study Breckenridge, MN #12;§ Construction Plans § Intersection Details for "tough

Minnesota, University of

172

Assessment of Building Energy-Saving Policies and Programs in China During the 11th Five Year Plan  

E-Print Network [OSTI]

building retrofits and heat supply system reform, followedof carrying out the heat supply system reform task. Buildingbuilding retrofits and heat supply system reform, followed

Zhou, Nan

2011-01-01T23:59:59.000Z

173

National Grid Deep Energy Retrofit Pilot  

SciTech Connect (OSTI)

Through discussion of five case studies (test homes), this project evaluates strategies to elevate the performance of existing homes to a level commensurate with best-in-class implementation of high-performance new construction homes. The test homes featured in this research activity participated in Deep Energy Retrofit (DER) Pilot Program sponsored by the electric and gas utility National Grid in Massachusetts and Rhode Island. Building enclosure retrofit strategies are evaluated for impact on durability and indoor air quality in addition to energy performance. Evaluation of strategies is structured around the critical control functions of water, airflow, vapor flow, and thermal control. The aim of the research project is to develop guidance that could serve as a foundation for wider adoption of high performance, 'deep' retrofit work. The project will identify risk factors endemic to advanced retrofit in the context of the general building type, configuration and vintage encountered in the National Grid DER Pilot. Results for the test homes are based on observation and performance testing of recently completed projects. Additional observation would be needed to fully gauge long-term energy performance, durability, and occupant comfort.

Neuhauser, K.

2012-03-01T23:59:59.000Z

174

Protocol for Maximizing Energy Savings and Indoor Environmental Quality Improvements when Retrofitting Apartments  

SciTech Connect (OSTI)

The current focus on building energy retrofit provides an opportunity to simultaneously improve indoor environmental quality (IEQ). Toward this end, we developed a protocol for selecting packages of retrofits that both save energy and improve IEQ in apartments. The protocol specifies the methodology for selecting retrofits from a candidate list while addressing expected energy savings, IEQ impacts, and costs in an integrated manner. Interviews, inspections and measurements are specified to collect the needed input information. The protocol was applied to 17 apartments in three buildings in two different climates within California. Diagnostic measurements and surveys conducted before and after retrofit implementation indicate enhanced apartment performance.

Noris, Federico; Delp, William W.; Vermeer, Kimberly; Adamkiewicz, Gary; Singer, Brett C.; Fisk, William J.

2012-06-18T23:59:59.000Z

175

Rule to Support Increased Energy Measurement and Efficient Building...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

for new and retrofitted federal buildings that are certified by private sector green building certification systems. The use of green building rating systems advances...

176

Energy Innovation Hub Report Shows Philadelphia-area Building...  

Energy Savers [EERE]

Hub Report Shows Philadelphia-area Building Retrofits Could Support 23,500 Jobs Energy Innovation Hub Report Shows Philadelphia-area Building Retrofits Could Support 23,500...

177

Passive retrofits for Navy housing  

SciTech Connect (OSTI)

A project to assess and initiate passive solar energy retrofits to US Navy family housing is described. The current data base for Navy housing (ECOP), and its enhancement for passive solar purposes options proposed for Navy housing are explained. The analysis goals and methods to evaluate the retrofits are discussed. An educational package to explain the retrofits is described.

Hibbert, R.; Miles, C.; Jones, R.; Peck, C.; Anderson, J.; Jacobson, V.; Dale, A.M.

1985-01-01T23:59:59.000Z

178

High-Efficiency Retrofit Lessons for Retail from a SuperTarget: Preprint  

SciTech Connect (OSTI)

The National Renewable Energy Laboratory partnered with Target under the Commercial Building Program to design and implement a retrofit of a SuperTarget in Thornton, CO. The result was a retrofit design that predicted 37% energy savings over ASHRAE Standard 90.1-2004, and 29% compared to existing (pre-retrofit) store consumption. The largest savings came from energy efficient lighting, energy efficient cooling systems, improved refrigeration, and better control of plug loads.

Langner, R.; Deru, M.; Hirsch, A.; Williams, S.

2013-02-01T23:59:59.000Z

179

Chamberlain Heights Redevelopment: A Large Scale, Cold Climate Study of Affordable Housing Retrofits  

SciTech Connect (OSTI)

The City of Meriden Housing Authority (MHA) collaborated with affordable housing developer Jonathon Rose Companies (JRC) to complete a gut renovation of 124 residential units in the Chamberlain Heights retrofit project. The affordable housing community is made up of 36 buildings in duplex and quad configurations located on 22 acres within two miles of downtown Meriden, CT. The final post-retrofit analysis showed 40-45% source energy savings over the existing pre-retrofit conditions.

Donnelly, K.; Mahle, M.

2012-03-01T23:59:59.000Z

180

Assessment of Building Energy-Saving Policies and Programs in China During the 11th Five Year Plan  

E-Print Network [OSTI]

retrofit in northern area district heating Special fund forbuildings that have district heating system (Wu, 2009). The

Zhou, Nan

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Assessment of Building Energy-Saving Policies and Programs in China During the 11th Five Year Plan  

E-Print Network [OSTI]

retrofit in northern area district heating Special fund forbuildings that have district heating system (Wu, 2009). The

Zhou, Nan

2010-01-01T23:59:59.000Z

182

Cascade Apartments: Deep Energy Multifamily Retrofit  

SciTech Connect (OSTI)

In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington (marine climate.)This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary BA research questions : 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio (SIR) of the retrofit package after considering utility window incentives and KCHA capitol improvement funding.

Gordon, A.; Mattheis, L.; Kunkle, R.; Howard, L.; Lubliner, M.

2014-02-01T23:59:59.000Z

183

Overview of PIER-Funded Existing Building Commissioning and Diagnostics Research  

E-Print Network [OSTI]

), Pacific Gas and Electric ? Whole Building Diagnostician (WBD) outdoor air economizer module and whole building energy module, Pacific Northwest National Laboratory ? Performance And Continuous Recommissioning Analysis Tool (PACRAT), Facility...

Jenkins, N.; Brook, M.

2003-01-01T23:59:59.000Z

184

Better Buildings Webinar: Making Utility Energy Efficiency Funds Work for You  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy's Better Buildings will host a webinar on innovative collaborations with utilities to bring big energy savings to their building portfolios and help reduce utility peak electricity demand.

185

Greenbuilt Retrofit Test House Final Report  

SciTech Connect (OSTI)

The Greenbuilt house, is an all-electric, 1980's era home in the eastern Sacramento suburb of Fair Oaks that was retrofit by Greenbuilt Construction as part of Sacramento Municipal Utility District's (SMUD) Energy Efficient Remodel Demonstration (EERD) Program. The project was a joint effort between the design-build team at Greenbuilt Construction, led by Jim Bayless, SMUD and their project manager Mike Keesee, and the National Renewable Energy Laboratory (NREL). The goal of the Energy Efficient Remodel Demonstration program is to work with local builders to renovate homes with cost-effective energy efficient retrofit measures. The homes remodeled under the EERD program are intended to showcase energy efficient retrofit options for homeowners and other builders. The Greenbuilt house is one of five EERD projects that NREL has supported. NREL's main role in these projects is to provide energy analysis and to monitor the home's performance after the retrofit to verify that the energy consumption is in line with the modeling predictions. NREL also performed detailed monitoring on the more innovative equipment included in these remodels, such as an add-on heat pump water heater.

Sparn, B.; Hudon, K.; Earle, L.; Booten, C.; Tabares-Velasco, P. C.; Barker, G.; Hancock, C. E.

2014-06-01T23:59:59.000Z

186

Expert Meeting Report: Retrofit Implementation - A Neighborhood at a Time  

SciTech Connect (OSTI)

This report provides information about a Building America expert meeting hosted by research team Consortium for Advanced Residential Buildings on October 25, 2011, in New York City. The meeting discussed several community residential retrofit projects underway across the United States, and included representatives from utilities, energy program implementation firms, affordable housing agencies, and the financing industry.

Griffiths, D.

2012-04-01T23:59:59.000Z

187

Short-Term Test Results: Transitional Housing Energy Efficiency Retrofit in the Hot-Humid Climate  

SciTech Connect (OSTI)

This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

Sutherland, K.; Martin, E.

2013-02-01T23:59:59.000Z

188

Seismic retrofit of concrete-encased riveted stiffened seat angle connections  

E-Print Network [OSTI]

Seismic retrofit of concrete-encased riveted stiffened seat angle connections Michel Bruneau Ottawa: Seismic retrofit, semi-rigid connections, concrete-encased, stiffened seat, ductile steel fuse, riveted frequently found in buildings constructed in the seismic zones of Eastern North America prior

Bruneau, Michel

189

Instructions for "The Great Energy Predictor Shootout II: Measuring Retrofit Energy Savings"  

E-Print Network [OSTI]

and compare how those models can be used to calculate energy conservation retrofit savings. ASHRAE's TC 1.5 and TC 4.7 have authorized a "Building Energy Predictor Shootout II: Measuring Retrofit Energy Savings" which is the focus of this competition....

Haberl, J. S.; Kreider, J. F.

1994-01-01T23:59:59.000Z

190

Evaluation of a Multifamily Retrofit in Climate Zone 5, Boulder, Colorado (Fact Sheet)  

SciTech Connect (OSTI)

In 2009, a 37-unit apartment complex located in Boulder, Colorado, underwent an energy retrofit to comply with Boulder SmartRegs Ordinance, a mandate that requires all rental properties to meet certain energy efficiency standards by 2018. The Consortium of Advanced Residential Buildings (CARB), a U.S. Department of Energy Building America team, worked with city planners and building owners to evaluate this program and recently completed a case study evaluating the effectiveness of a collection of retrofit measures.

Not Available

2013-11-01T23:59:59.000Z

191

Performance of a Hot-Dry Climate Whole-House Retrofit  

SciTech Connect (OSTI)

The Stockton house retrofit is a two-story tudor style single family deep retrofit in the hot-dry climate of Stockton, CA. The home is representative of a deep retrofit option of the scaled home energy upgrade packages offered to targeted neighborhoods under the pilot Large-Scale Retrofit Program (LSRP) administered by the Alliance for Residential Building Innovation (ARBI). Deep retrofit packages expand on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Site energy savings with the deep retrofit were 23% compared to the pre-retrofit case, and 15% higher than the savings estimated for the standard retrofit package. Energy savings were largely a result of the water heater upgrade, and a combination of the envelope sealing, insulation and HVAC upgrade. The HVAC system was of higher efficiency than the building code standard. Overall the financed retrofit would have been more cost effective had a less expensive HVAC system been selected and barriers to wall insulation remedied. The homeowner experienced improved comfort throughout the monitored period and was satisfied with the resulting utility bill savings.

Weitzel, E.; German, A.; Porse, E.

2014-06-01T23:59:59.000Z

192

Compressed Air System Analysis and Retrofit for Energy Savings  

E-Print Network [OSTI]

several actions including piping retrofits, equipment upgrades, pressure control changes, and compressor retrofits....

Harding, C.; Nutter, D.

2014-01-01T23:59:59.000Z

193

Grupe Homes Enters the Whole-House Retrofit Market  

SciTech Connect (OSTI)

This article for HomeEnergy Magazine, a trade magazine on energy efficient home construction, retrofitting, remodeling, and research, describes retrofit projects by Grupe Homes of Sacramento, California, a production builder who has worked with DOE's Building America program on energy-efficient home demonstration projects. In this project, The article is a case study of Grupe's decision to enter the energy efficient remodeling market when new home sales lagged due to the economic slowdown starting in late 2007. The article also describes an energy-efficient retrofit of of a 22-year-old, 3-bedroom home in California’s Central Valley done in 2009 by Grupe. The home is Grupe's first retrofit and was done according to the criteria of Home Performance with ENERGY STAR, a national program from the EPA and DOE that promotes a comprehensive, whole-house approach to making energy-efficiency improvements. Grupe's staff were trained through the California Building Performance Contractors Association and passed the Building Performance Institute test to learn how to conduct extensive energy audits of existing houses as well to perform the energy efficient retrofits. In the retrofit home, they did extensive air sealing, replaced and added insulation, and replaced inefficient HVAC equipment and leaky can lights. They cut air leakage from 2478 to 1115 cfm 50, a 55% reduction. A Building America case study on this project was distributed at the EEBA (Energy and Environmental Building Alliance) Annual Conference in Denver, Colorado, Sept 28-30, 2009. The Home Energy article was published in the March/April 2010 issue.

Hefty, Marye G.; Gilbride, Theresa L.

2010-03-01T23:59:59.000Z

194

PSNH- Small Business Retrofit Program  

Broader source: Energy.gov [DOE]

Public Service of New Hampshire (PSNH), an electric utility, offers financial incentives and technical advice to small business customers seeking to improve energy efficiency through retrofits....

195

Quality Assurance for Residential Retrofit Programs | Department...  

Broader source: Energy.gov (indexed) [DOE]

Quality Assurance for Residential Retrofit Programs Quality Assurance for Residential Retrofit Programs Blue version of the EERE PowerPoint template, for use with PowerPoint 2007....

196

Pilot Residential Deep Energy Retrofits and the PNNL Lab Homes  

SciTech Connect (OSTI)

This report summarizes research investigating the technical and economic feasibility of several pilot deep energy retrofits, or retrofits that save 30% to 50% or more on a whole-house basis while increasing comfort, durability, combustion safety, and indoor air quality. The work is being conducted for the U.S. Department of Energy Building Technologies Program as part of the Building America Program. As part of the overall program, Pacific Northwest National Laboratory (PNNL) researchers are collecting and analyzing a comprehensive dataset that describes pre- and post-retrofit energy consumption, retrofit measure cost, health and comfort impacts, and other pertinent information for each home participating in the study. The research and data collection protocol includes recruitment of candidate residences, a thorough test-in audit, home energy modeling, and generation of retrofit measure recommendations, implementation of the measures, test-out, and continued evaluation. On some homes, more detailed data will be collected to disaggregate energy-consumption information. This multi-year effort began in October 2010. To date, the PNNL team has performed test-in audits on 51 homes in the marine, cold, and hot-humid climate zones, and completed 3 retrofits in Texas, 10 in Florida, and 2 in the Pacific Northwest. Two of the retrofits are anticipated to save 50% or more in energy bills and the others - savings are in the 30% to 40% range. Fourteen other retrofits are under way in the three climate zones. Metering equipment has been installed in seven of these retrofits - three in Texas, three in Florida, and one in the Pacific Northwest. This report is an interim update, providing information on the research protocol and status of the PNNL deep energy retrofit project as of December, 2011. The report also presents key findings and lessons learned, based on the body of work to date. In addition, the report summarizes the status of the PNNL Lab Homes that are new manufactured homes procured with minimal energy-efficiency specifications typical of existing homes in the region, and sited on the PNNL campus. The Lab Homes serve as a flexible test facility (the first of its kind in the Pacific Northwest) to rapidly evaluate energy-efficient and grid-smart technologies that are applicable to residential construction.

Widder, Sarah H.; Chandra, Subrato; Parker, Graham B.; Sande, Susan; Blanchard, Jeremy; Stroer, Dennis; McIlvaine, Janet; Chasar, David; Beal, David; Sutherland, Karen

2012-01-01T23:59:59.000Z

197

Measuring Energy-Saving Retrofits: Experiences from the LoanSTAR Program  

E-Print Network [OSTI]

school, and local government buildings. As part of this program, a first-of-its-kind, statewide Monitoring and Analysis Program (MAP) was established to verify energy and dollar savings of the retrofits, reduce energy costs by identifying operational...

Claridge, D. E.; Heffington, W. M.; O'Neal, D. L.; Turner, W. D.; Haberl, J. S.; Reddy, T. A.

2005-09-27T23:59:59.000Z

198

Retrofit of the Local 150 of International Union of Operating Engineers  

Broader source: Energy.gov [DOE]

Project objectives: Demonstrate the reduced first cost impact of smart geothermal design and technology. Demonstrate smart geothermal innovations in system efficiency, especially in the building-earth interaction. Demonstrate an economical and repeatable approach to district, hybrid retrofit GHP systems.

199

Seismic fragility and retrofitting for a reinforced concrete flat-slab structure  

E-Print Network [OSTI]

The effectiveness of seismic retrofitting applied to enhance seismic performance was assessed for a five-story reinforced concrete (RC) flat-slab building structure in the central United States. In addition to this, an assessment of seismic...

Bai, Jong-Wha

2004-09-30T23:59:59.000Z

200

JOURNAL OF STRUCTURAL ENGINEERING / SEPTEMBER 2000 / 1017 SEISMIC RETROFITTING OF LOW-RISE MASONRY AND CONCRETE  

E-Print Network [OSTI]

the architectural aesthetics of the building. Hence, an alternative method of retrofitting is worth considering Hall, Dept. of Civ., Struct., and Envir. Engrg., State Univ. of New York, Buffalo, NY 14260. E

Bruneau, Michel

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

EnergyFit Nevada (formerly known as the Nevada Retrofit Initiative) final report and technical evaluation  

SciTech Connect (OSTI)

The EnergyFit Nevada (EFN) Better Buildings Neighborhood Program (BBNP, and referred to in this document as the EFN program) currently encourages Nevada residents to make whole-house energy-efficient improvements by providing rebates, financing, and access to a network of qualified home improvement contractors. The BBNP funding, consisting of 34 Energy Efficiency Conservation Block Grants (EECBG) and seven State Energy Program (SEP) grants, was awarded for a three-year period to the State of Nevada in 2010 and used for initial program design and implementation. By the end of first quarter in 2014, the program had achieved upgrades in 553 homes, with an average energy reduction of 32% per home. Other achievements included: ? Completed 893 residential energy audits and installed upgrades in 0.05% of all Nevada single-family homes1 ? Achieved an overall conversation rate of 38.1%2 ? 7,089,089 kWh of modeled energy savings3 ? Total annual homeowner energy savings of approximately $525,7523 ? Efficiency upgrades completed on 1,100,484 square feet of homes3 ? $139,992 granted in loans to homeowners for energy-efficiency upgrades ? 29,285 hours of labor and $3,864,272 worth of work conducted by Nevada auditors and contractors4 ? 40 contractors trained in Nevada ? 37 contractors with Building Performance Institute (BPI) certification in Nevada ? 19 contractors actively participating in the EFN program in Nevada 1 Calculated using 2012 U.S. Census data reporting 1,182,870 homes in Nevada. 2 Conversion rate through March 31, 2014, for all Nevada Retrofit Initiative (NRI)-funded projects, calculated using the EFN tracking database. 3 OptiMiser energy modeling, based on current utility rates. 4 This is the sum of $3,596,561 in retrofit invoice value and $247,711 in audit invoice value.

Carvill, Anna; Bushman, Kate; Ellsworth, Amy

2014-06-17T23:59:59.000Z

202

Short-Term Test Results: Multifamily Home Energy Efficiency Retrofit  

SciTech Connect (OSTI)

Multifamily deep energy retrofits (DERs) represent great potential for energy savings, while also providing valuable insights on research-generated efficiency measures, cost-effectiveness metrics, and risk factor strategies for the multifamily housing industry. The Bay Ridge project is comprised of a base scope retrofit with a goal of achieving 30% savings (relative to pre-retrofit), and a DER scope with a goal of 50% savings (relative to pre-retrofit). The base scope has been applied to the entire complex, except for one 12-unit building which underwent the DER scope. Findings from the implementation, commissioning, and short-term testing at Bay Ridge include air infiltration reductions of greater than 60% in the DER building; a hybrid heat pump system with a Savings to Investment Ratio (SIR) > 1 (relative to a high efficiency furnace) which also provides the resident with added incentive for energy savings; and duct leakage reductions of > 60% using an aerosolized duct sealing approach. Despite being a moderate rehab instead of a gut rehab, the Bay Ridge DER is currently projected to achieve energy savings ? 50% compared to pre-retrofit, and the short-term testing supports this estimate.

Lyons, J.

2013-01-01T23:59:59.000Z

203

Apply: Building Energy Efficiency Frontiers and Innovation Technologies (BENEFIT)- 2015 Funding Opportunity Announcement  

Broader source: Energy.gov [DOE]

Deadline for Concept Papers: November 10, 2014, 5:00 PM ET This Building Energy Efficiency Frontiers and Innovations Technologies (BENEFIT) 2015 FOA contributes to advancement in two core technological areas: non-vapor compression HVAC technologies and advanced vapor compression HVAC technologies.

204

Federally Funded Programs Related to Building Energy Use: Overlaps, Challenges, and Opportunities for Collaboration  

SciTech Connect (OSTI)

As energy efficiency in buildings continues to move from discreet technology development to an integrated systems approach, the need to understand and integrate complementary goals and targets becomes more pronounced. Whether within Department of Energy’s (DOE) Building Technologies Program (BTP), across the Office of Energy Efficiency and Renewable Energy (EERE), or throughout DOE and the Federal government, mutual gains and collaboration synergies exist that are not easily achieved because of organizational and time constraints. There also cases where federal agencies may be addressing similar issues, but with different (and sometimes conflicting) outcomes in mind. This report conducts a comprehensive inventory across all EERE and other relevant Federal agencies of potential activities with synergistic benefits. A taxonomy of activities with potential interdependencies is presented. The report identifies a number of federal program objectives, products, and plans related to building energy efficiency and characterizes the current structure and interactions related to these plans and programs. Areas where overlap occurs are identified as are the challenges of addressing issues related to overlapping goals and programs. Based on the input gathered from various sources, including 20 separate interviews with federal agency staff and contractor staff supporting buildings programs, this study identifies a number of synergistic opportunities and makes recommends a number of areas where further collaboration could be beneficial.

Cort, Katherine A.; Butner, Ryan S.; Hostick, Donna J.

2010-10-01T23:59:59.000Z

205

Energy and Indoor Environmental Quality Retrofits in Low-Income  

E-Print Network [OSTI]

Buildings are responsible for about 40 percent of the total U.S. energy demand and carbon dioxide environmental measurements and collect energy consumption data. Based on analyses of the data collected fromEnergy and Indoor Environmental Quality Retrofits in Low-Income Apartments ENVIRONMENTAL ENERGY

206

Process Energy Retrofits  

E-Print Network [OSTI]

shows up in a discharge of added heat to ambient and is spotted more quickly. (Not Replace) I~ - ......... c.... Doml..... By IneremanUl Coata Area Fortunately, there are snort CIrcUits past some of the other activation energy barriers...optimum Is the low point on the curve. The discontinuity or activation energy Is due to the coats.of weatherproofing, etc. Note that for this exlsti" Process Energy Retrofits Dan Steinmeyer Monsanto Co St. Louis, Mo U N C E R E T N...

Steinmeyer, D.

207

Post-Retrofit Residential Assessments  

SciTech Connect (OSTI)

This study examined a range of factors influencing energy consumption in households that had participated in residential energy-efficiency upgrades. The study was funded by a grant from the U.S. Department of Energy’s Pacific Northwest National Laboratory and was conducted by faculty and staff of Portland State University Center for Urban Studies and Department of Economics. This work was made possible through the assistance and support of the Energy Trust of Oregon (ETO), whose residential energy-efficiency programs provided the population from which the sample cases were drawn. All households in the study had participated in the ETO Home Performance with Energy Star (HPwES) program. A number of these had concurrently pursued measures through other ETO programs. Post-retrofit energy outcomes are rarely investigated on a house-by-house basis. Rather, aggregate changes are ordinarily the focus of program impact evaluations, with deviation from aggregate expectations chalked up to measurement error, the vagaries of weather and idiosyncrasies of occupants. However, understanding how homes perform post-retrofit on an individual basis can give important insights to increase energy savings at the participant and the programmatic level. Taking a more disaggregated approach, this study analyzed energy consumption data from before and after the retrofit activity and made comparisons with engineering estimates for the upgrades, to identify households that performed differently from what may have been expected based on the estimates. A statistical analysis using hierarchal linear models, which accounted for weather variations, was performed looking separately at gas and electrical use during the periods before and after upgrades took place. A more straightforward comparison of billing data for 12-month periods before and after the intervention was also performed, yielding the majority of the cases examined. The later approach allowed total energy use and costs to be assessed but did not account for weather variation. From this statistical analysis, 18 study participants were selected and interviewed. The participants completed an in-home interview covering a range of topics, including changes in occupancy and additional changes to the homes that may have affected energy use. The goal of the interviews was to identify factors that may have contributed to unusual energy performance. These factors were identified by their frequency of occurrence in outperforming or underperforming homes, or simply by identifying factors that had the largest impact on overall savings. The motivations and levels of satisfaction with the outcomes of the upgrades were covered in detail, as well as extensive discussions of behaviors pertaining to thermal control, lighting, water, and appliance use. Most of cases studied achieved substantial energy savings, although it was more common for the projected savings to be greater than the demonstrated savings. Two factors that played a very large role in savings variation were 1) changes in occupancy and 2) fenestration improvements outside of the incentive programs. Motivation for pursuing the upgrades (e.g., environmental sustainability vs. comfort or cost savings) did not seem to play any role in achieving savings. Participants generally were more concerned with maintaining aesthetics through lighting than comfort through heating or cooling. They also seemed more likely to turn the lights off when leaving a room than to turn the heat off when leaving the home.

Lancaster, Ross; lutzenhiser, Loren; Moezzi, Mithra; Widder, Sarah H.; Chandra, Subrato; Baechler, Michael C.

2012-04-30T23:59:59.000Z

208

Residential Retrofit Design Guide Overview | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Residential Retrofit Design Guide Overview Residential Retrofit Design Guide Overview Residential Retrofit Design Guide Overview Webinar. Res Retro Design Guide Webinar 5-3-11...

209

Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study  

SciTech Connect (OSTI)

Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programs are discussed in detail.

Dentz, J.; Podorson, D.; Varshney, K.

2014-05-01T23:59:59.000Z

210

Cook County- LEED Requirements for County Buildings  

Broader source: Energy.gov [DOE]

In 2002, Cook County enacted an ordinance requiring all new county buildings and all retrofitted county buildings to be built to LEED standards. Specifically, all newly constructed buildings and...

211

Air Distribution Retrofit Strategies for Affordable Housing  

SciTech Connect (OSTI)

In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

Dentz, J.; Conlin, F.; Holloway, P.; Podorson, D.; Varshney, K.

2014-03-01T23:59:59.000Z

212

Advancing Residential Retrofits in Atlanta  

SciTech Connect (OSTI)

This report will summarize the home energy improvements performed in the Atlanta, GA area. In total, nine homes were retrofitted with eight of the homes having predicted source energy savings of approximately 30% or greater based on simulated energy consumption.

Jackson, Roderick K [ORNL; Kim, Eyu-Jin [Southface Energy Institute; Roberts, Sydney [Southface Energy Institute; Stephenson, Robert [Southface Energy Institute

2012-07-01T23:59:59.000Z

213

Group Home Energy Efficiency Retrofit for 30% Energy Savings: Washington, D.C. (Fact Sheet)  

SciTech Connect (OSTI)

Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes - such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost-effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the study's results will be used to identify cost effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

Not Available

2013-11-01T23:59:59.000Z

214

Retrofitting the Southeast: The Cool Energy House  

SciTech Connect (OSTI)

The Consortium for Advanced Residential Buildings has provided the technical engineering and building science support for a highly visible demonstration home in connection with the National Association of Home Builders' International Builders Show. The two previous projects, the Las Vegas net-zero ReVISION House and the 2011 VISION and ReVISION Houses in Orlando, met goals for energy efficiency, cost effectiveness, and information dissemination through multiple web-based venues. This project, which was unveiled at the 2012 International Builders Show in Orlando on February 9, is the deep energy retrofit Cool Energy House (CEH). The CEH began as a mid-1990s two-story traditional specification house of about 4,000 ft2 in the upscale Orlando suburb of Windermere.

Zoeller, W.; Shapiro, C.; Vijayakumar, G.; Puttagunta, S.

2013-02-01T23:59:59.000Z

215

Case study field evaluation of a systems approach to retrofitting a residential HVAC system  

SciTech Connect (OSTI)

This case study focusing on a residence in northern California was undertaken as a demonstration of the potential of a systems approach to HVAC retrofits. The systems approach means that other retrofits that can affect the HVAC system are also considered. For example, added building envelope insulation reduces building loads so that smaller capacity HVAC system can be used. Secondly, we wanted to examine the practical issues and interactions with contractors and code officials required to accomplish the systems approach because it represents a departure from current practice. We identified problems in the processes of communication and installation of the retrofit that led to compromises in the final energy efficiency of the HVAC system. These issues must be overcome in order for HVAC retrofits to deliver the increased performance that they promise. The experience gained in this case study was used to optimize best practices guidelines for contractors (Walker 2003) that include building diagnostics and checklists as tools to assist in ensuring the energy efficiency of ''house as a system'' HVAC retrofits. The best practices guidelines proved to be an excellent tool for evaluating the eight existing homes in this study, and we received positive feedback from many potential users who reviewed and used them. In addition, we were able to substantially improve the energy efficiency of the retrofitted case study house by adding envelope insulation, a more efficient furnace and air conditioner, an economizer and by reducing duct leakage.

Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

2003-09-01T23:59:59.000Z

216

Charlotte Green Supply Chain: Residential Retrofitting | Department...  

Broader source: Energy.gov (indexed) [DOE]

Charlotte Green Supply Chain: Residential Retrofitting Charlotte Green Supply Chain: Residential Retrofitting July 30, 2010 - 10:50am Addthis Joshua DeLung What does this mean for...

217

Newporter Apartments: Deep Energy Retrofit Short-Term Results  

SciTech Connect (OSTI)

This project demonstrates a path to meet the goal of the Building America program to reduce home energy use by 30% in multi-family buildings. The project demonstrates cost effective energy savings targets as well as improved comfort and indoor environmental quality (IEQ) associated with deep energy retrofits by a large public housing authority as part of a larger rehabilitation effort. The project focuses on a typical 1960's vintage low-rise multi-family apartment community (120 units in three buildings).

Gordon, A.; Howard, L.; Kunkle, R.; Lubliner, M.; Auer, D.; Clegg, Z.

2012-12-01T23:59:59.000Z

218

Seismic retrofitting of deficient Canadian buildings  

E-Print Network [OSTI]

Many developed countries such as Canada and the United States are facing a significant infrastructure crisis. Most of their facilities have been built with little consideration of seismic design and durability issues. As ...

Gemme, Marie-Claude

2009-01-01T23:59:59.000Z

219

Mixed-Mode Ventilation and Building Retrofits  

E-Print Network [OSTI]

CBEEDAC). University College Dublin. 1997. Solar Energy inintervention. University College Dublin. 1997. Solar Energy

Brager, Gail; Ackerly, Katie

2010-01-01T23:59:59.000Z

220

Building America Expert Meeting: Retrofit Implementation - A...  

Energy Savers [EERE]

projects underway across the United States, and included representatives from utilities, energy program implementation firms, affordable housing agencies, and the financing...

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Building America Webinar: Retrofitting Central Space Conditioning...  

Energy Savers [EERE]

increased main line air venting, replacing radiator vents, improving circulation pump efficiency, and upgrading boiler control systems. BAwebinarruchludwig716-14.pdf More...

222

Retrofit Existing Buildings | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartment of Energy fromComments onReplyofRetiring Procurement Official

223

Building America Retrofit Participation Requirements and Release |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 < prev next > Sun Mon Tue Wed ThuChallenge

224

Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance, K-12 Schools (Book)  

SciTech Connect (OSTI)

The U.S. Department of Energy developed the K-12 Advanced Energy Retrofit Guide to provide specific methodologies, information, and guidance to help energy managers and other stakeholders plan and execute energy efficiency improvements. We emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluation of the most promising retrofit measure for each building type. K-12 schools were selected as one of the highest priority building sectors, because schools affect the lives of most Americans. They also represent approximately 8% of the energy use and 10% of the floor area in commercial buildings.

Not Available

2013-02-01T23:59:59.000Z

225

Bay Ridge Gardens - Mixed-Humid Affordable Multifamily Housing Deep Energy Retrofit  

SciTech Connect (OSTI)

Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place DER at the Bay Ridge multifamily (MF) development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a 'base scope' retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a 'DER scope' which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. The base scope was applied to the entire apartment complex, except for one 12-unit building which underwent the DER scope. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

Lyons, J.; Moore, M.; Thompson, M.

2013-08-01T23:59:59.000Z

226

Cascade Apartments - Deep Energy Multifamily Retrofit , Kent, Washington (Fact Sheet)  

SciTech Connect (OSTI)

In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington (marine climate.)This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary BA research questions : 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio (SIR) of the retrofit package after considering utility window incentives and KCHA capitol improvement funding.

Not Available

2014-02-01T23:59:59.000Z

227

Passive solar retrofit: an investment for the future  

SciTech Connect (OSTI)

America has a large inventory of older buildings which are directly contributing to the energy crunch. These liabilities could be converted to assets with the proper application of conservation and solar techniques. Through the use of one typical example, the economic and social benefits of such a conversion are discussed. A somewhat unusual method of financing is described, and a set of economic criteria often overlooked in the evaluation of a solar retrofit potential is addressed.

Balcomb, S.A.

1980-01-01T23:59:59.000Z

228

Light-RITE California The Lighting Retrofit Information, Training and Education program  

E-Print Network [OSTI]

to implementing best practices in California's public buildings Professor Michael Siminovitch (co-author with UC, CSC, CCC, CIEE, DGS) UC Davis Rosenfeld Chair in Energy Efficiency The Consortium of Public Building makers on the implementation of best practices for lighting retrofits. We need to quickly develop

California at Davis, University of

229

Building America Webinar: Who's Successfully Doing Deep Energy...  

Broader source: Energy.gov (indexed) [DOE]

are receiving phased energy-saving retrofits in Florida. View the presentation. Alea German, Alliance for Residential Building Innovation, described results from three case...

230

Building America Whole-House Solutions for Existing Homes: Evaluation...  

Broader source: Energy.gov (indexed) [DOE]

residential retrofits to those recommended as cost-optimal by Building Energy Optimization (BEopt) modeling software. bacasestudyillinoishomeperf.pdf More Documents &...

231

Use of advanced composite materials for innovative building design solutions/  

E-Print Network [OSTI]

Advanced composite materials become popular in construction industry for the innovative building design solutions including strengthening and retrofitting of existing structures. The interface between different materials ...

Lau, Tak-bun, Denvid

2009-01-01T23:59:59.000Z

232

Building America Whole-House Solutions for Existing Homes: Applying...  

Energy Savers [EERE]

to Florida Local Government Retrofit Programs - Central Florida (Fact Sheet) Building America Whole-House Solutions for Existing Homes: Applying Best Practices to Florida...

233

Building America Whole-House Solutions for Existing Homes: Applying...  

Broader source: Energy.gov (indexed) [DOE]

Existing Homes: Pilot Demonstration of Phased Retrofits in Florida Homes - Central and South Florida (Fact Sheet) Building America Efficient Solutions for Existing Homes: Case...

234

Building America Expert Meeting Final Report: Multifamily Hydronic...  

Broader source: Energy.gov (indexed) [DOE]

Meeting Final Report: Multifamily Hydronic and Steam Heating Controls and Distribution Retrofits Building America Expert Meeting Final Report: Multifamily Hydronic and Steam...

235

LED Lighting Retrofit  

E-Print Network [OSTI]

? Municipal Street Lighting Consortium ? American Public Power Association (APPA) ? Demonstration in Energy Efficiency Development (DEED) ? Source of funding and database of completed LED roadway projects 6 Rules of the Road ESL-KT-11-11-57 CATEE 2011..., 2011 ? 9 Solar-Assisted LED Case Study LaQuinta Hotel, Cedar Park, Texas ? Utilizes 18 - ActiveLED Solar-Assisted Parking Lot Lights ? Utilizes ?power management? to extend battery life while handling light output ? Reduces load which reduces PV...

Shaw-Meadow, N.

2011-01-01T23:59:59.000Z

236

Assessment of Building Energy-Saving Policies and Programs in China During the 11th Five Year Plan  

E-Print Network [OSTI]

building retrofits and heat supply system reform, followedretrofit particularly heat supply system reform lags theof carrying out the heat supply system reform task. Building

Zhou, Nan

2010-01-01T23:59:59.000Z

237

National Residential Efficiency Measures Database Aimed at Reducing Risk for Residential Retrofit Industry (Fact Sheet)  

SciTech Connect (OSTI)

This technical highlight describes NREL research to develop a publicly available database of energy retrofit measures containing performance characteristics and cost estimates for nearly 3,000 measures. Researchers at the U.S. Department of Energy (DOE) National Renewable Energy Laboratory (NREL) have developed the National Residential Efficiency Measures Database, a public database that characterizes the performance and costs of common residential energy efficiency measures. The data are available for use in software programs that evaluate cost-effective retrofit measures to improve the energy efficiency of residential buildings. The database provides a single, consistent source of current data for DOE and private-sector energy audit and simulation software tools and the retrofit industry. The database will reduce risk for residential retrofit industry stakeholders by providing a central, publicly vetted source of up-to-date information.

Not Available

2012-01-01T23:59:59.000Z

238

National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet)  

SciTech Connect (OSTI)

Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a DER pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. 37 of these projects were comprehensive retrofits while 5 were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. The 42 DER projects represent 60 units of housing. The comprehensive projects all implemented a consistent "package" of measures in terms of the performance targeted for major building components. Projects exhibited some variations in the approach to implementing the retrofit package. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects. Post-retrofit energy use was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Homeowner surveys were returned by 12 of the pilot participants. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

Not Available

2014-03-01T23:59:59.000Z

239

Performance Results for Massachusetts and Rhode Island Deep Energy Retrofit Pilot Community  

SciTech Connect (OSTI)

Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a DER pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. 37 of these projects were comprehensive retrofits while 5 were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. The 42 DER projects represent 60 units of housing. The comprehensive projects all implemented a consistent 'package' of measures in terms of the performance targeted for major building components. Projects exhibited some variations in the approach to implementing the retrofit package. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects. Post-retrofit energy use was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Homeowner surveys were returned by 12 of the pilot participants. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

Gates, C.; Neuhauser, K.

2014-03-01T23:59:59.000Z

240

Hybrid Model of Existing Buildings for Transient Thermal Performance Estimation  

E-Print Network [OSTI]

Building level energy models are important to provide accurate prediction of energy consumption for building performance diagnosis and energy efficiency assessment of retrofitting alternatives for building performance upgrading. Simplified...

Xu, X.; Wang, S.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Retrofit Savings for Brazos County  

E-Print Network [OSTI]

This report presents the energy and dollar savings for the period May 2000 - April 2001 for 10 of the Brazos County facilities that have been retrofit. The electricity use saved was 555,170 kWh and the demand was 1062 kW, which is equivalent to a...

Baltazar-Cervantes, J. C.; Shao, X.; Claridge, D. E.

2001-01-01T23:59:59.000Z

242

Funding Opportunity Webinar - Advancing Solutions To Improve...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Funding Opportunity Webinar - Advancing Solutions To Improve the Energy Efficiency of US Commercial Buildings Funding Opportunity Webinar - Advancing Solutions To Improve the...

243

City of Columbus- Green Columbus Fund  

Broader source: Energy.gov [DOE]

The Green Columbus Fund incentivizes sustainable development and redevelopment in Columbus, Ohio. The Fund reimburses private and non-profit developers the application fee for the Green Building...

244

High Performance Window Retrofit  

SciTech Connect (OSTI)

The US Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) and Traco partnered to develop high-performance windows for commercial building that are cost-effective. The main performance requirement for these windows was that they needed to have an R-value of at least 5 ft2 F h/Btu. This project seeks to quantify the potential energy savings from installing these windows in commercial buildings that are at least 20 years old. To this end, we are conducting evaluations at a two-story test facility that is representative of a commercial building from the 1980s, and are gathering measurements on the performance of its windows before and after double-pane, clear-glazed units are upgraded with R5 windows. Additionally, we will use these data to calibrate EnergyPlus models that we will allow us to extrapolate results to other climates. Findings from this project will provide empirical data on the benefits from high-performance windows, which will help promote their adoption in new and existing commercial buildings. This report describes the experimental setup, and includes some of the field and simulation results.

Shrestha, Som S [ORNL; Hun, Diana E [ORNL; Desjarlais, Andre Omer [ORNL

2013-12-01T23:59:59.000Z

245

Solicitation and Selection of Partner Projects, Technical Team Leads, and Measurement and Validation Contractors for the American Recovery and Reinvestment Act (ARRA) Funded Commercial Building Partnerships (CBP-2)  

SciTech Connect (OSTI)

In March 2010, Pacific Northwest National Laboratory (PNNL) joined two other labs receiving ARRA funding, Lawrence Berkeley National Laboratory (LBNL) and the National Renewable National Laboratory (NREL), to began weekly conference calls with the goal of coordinating a joint lab solicitation to support the ARRA-funded CBP project. Two solicitations were identified for: 1) new CBP Partners; 2) technical contractors to provide technical assistance and measurement and verification (M&V) contractors. The M&V contractors support the work by providing model reviews and conducting monitoring studies to verify building performance. This report documents the process used by the labs for the solicitations, and describes the process and outcomes for PNNL, selection of candidate Partners, technical teams, and M&V contractors.

Nesse, Ronald J.; Baechler, Michael C.; Iverson, Megan M.

2010-09-30T23:59:59.000Z

246

Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance; Grocery Stores (Revised) (Book)  

SciTech Connect (OSTI)

The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders successfully plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited in these guides. Instead, we emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluations of the most promising retrofit measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. Grocery stores were selected as one of the highest priority sectors, because they represent one of the most energy-intensive market segments.

Hendron, B.

2013-07-01T23:59:59.000Z

247

Retrofit for a college campus  

SciTech Connect (OSTI)

The Florissant Valley Campus of the St. Louis, MO Community College was constructed during the late 1960s and early 1970s. The main campus consists of 11 classroom, laboratory, and instructional buildings comprising 411,000 ft{sup 2} (38 183 m{sup 2}). The Florissant Valley campus wanted to provide the maintenance staff with a state-of-the-art DDC building automation system which would eliminate manual control of HVAC systems and reduce maintenance. Several of the classrooms and laboratories have had changes in their occupancy and use from the original design intent, and, the campus has consistently been adding additional internal load to many of the spaces in the form of new computers, printers, and other electronic equipment. The original campus HVAC systems were not designed to meet the indoor air quality (IAQ) standards of today. The college specifically requested that the design team prepare the project within DOE guidelines so that ICP grant funds could be used. The college also wanted to have the design team prepare the project in a manner to be bid by Energy Savings Contractors (ESCO) using a Guaranteed Energy Service Contract to assure the college could pay back their investment in the time stated.

Cox, R.L. [Avanti Consulting Engineering, St. Louis, MO (United States)

1996-11-01T23:59:59.000Z

248

Building America Webinar: High Performance Building Enclosures: Part I, Existing Homes  

Broader source: Energy.gov [DOE]

This webinar, presented on May 21, 2014, focused on specific Building America projects that have implemented technical solutions to retrofit building enclosures to reduce energy use and improve durability.

249

Occupant-in-Place Energy Efficiency Retrofit in a Group Home for 30% Energy Savings in Climate Zone 4  

SciTech Connect (OSTI)

Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes - such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost-effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the study's results will be used to identify cost effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

Moore, M.

2013-08-01T23:59:59.000Z

250

Funding and Federal Staffing Requirements Funding Summary (Energy Supply)  

E-Print Network [OSTI]

Funding and Federal Staffing Requirements Funding Summary (Energy Supply) (dollars in thousands) FY Buildings Zero Energy Building Design . . . . . 1,367 8,000 4,000 -4,000 -50.0% Total, Zero-Energy Buildings-Temperature Superconducting R&D . . . . . . . . . . . . . . . . . . . . . . 31,991 47,838 47,838 0 0.0% Energy Supply Energy

251

Retrofit for Plastic Resin Driers  

E-Print Network [OSTI]

RETROFIT FOR PLASTIC RESIN DRIERS BABU JOSEPH PH.D. Supervising Engineer Southern California Edison Company, Irwindale, California GEORGE THURO Thuro, & Associates, Costa Mesa, California Plastic resins used in injection molding have... installation of dew point meters and a programmable controller to tailor the regeneration cycle to the required dew point temperature. Background It was estimated that there are about 450 plastic processors in the Southern California Edison service...

Joseph, B.; Thuro, G.

252

Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits  

SciTech Connect (OSTI)

Exterior insulation and finish systems (EIFS) are proprietary synthetic formulations that are applied to the exterior walls of buildings to serve as insulation and exterior cladding. The insulation thickness can vary from less than one inch to a foot or more. In this project the applicability of EIFS for residential deep energy retrofits was investigated through modeling and a case study home. The home was retrofitted using a site-applied four-inch-thick EIFS. Site-specific details were developed as required for the residential retrofit application. Site work and the costs of the EIFS system were documented. The demonstration home was modeled using Building Energy Optimization energy and cost analysis software to explore cost effectiveness of various EIFS insulation thicknesses in two climate locations.

Dentz, J.; Podorson, D.

2014-01-01T23:59:59.000Z

253

Short-term measurements for the determination of envelope retrofit performance  

SciTech Connect (OSTI)

Short-term monitoring for estimating thermal parameters of a building, along with an analytical technique to (1) determine the long-term performance and (2) calculate the parameters from a building description, has many valuable applications, which include energy ratings, diagnostics, and retrofit analysis. In this paper we address issues relating to reducing uncertainties in estimating thermal parameters with emphasis on retrofit applications. In general, it is necessary to impose a known heat flow with a suitable profile to reliably estimate the parameters. This is demonstrated with test cell measurements taken before and after changes were made to the test cell. The eventual goal of this project is to develop a practical methodology to determine long-term retrofit performance from short-term tests.

Subbarao, K.; Mort, D.; Burch, J.

1985-06-01T23:59:59.000Z

254

SCR & DPF RETROFITS FOR MOBILE DIESEL ENGINES  

Broader source: Energy.gov (indexed) [DOE]

SCR & DPF RETROFITS FOR MOBILE DIESEL ENGINES Thierry Leprince & Phil Roberts Extengine Transport Systems, LLC 1370 South Acacia Avenue Fullerton, CA - 92831 www.extengine.com...

255

NIPSCO- Existing Facility Retrofit Rebate Program  

Broader source: Energy.gov [DOE]

Northern Indiana Public Service Corporation (NIPSCO) offers incentives to commercial, industrial, nonprofit, government, and institutional customers for replacing or retrofitting equipment or...

256

Homeowner Best Practices Guide for Residential Retrofits  

E-Print Network [OSTI]

retrofitting your homes heating, cooling and ventilationranch style homes getting insufficient heating or cooling.bridge. Adequately heating all of your home is equally

Walker, Iain S.

2011-01-01T23:59:59.000Z

257

OTEC- Commercial Lighting Retrofit Rebate Program  

Broader source: Energy.gov [DOE]

The Oregon Trail Electric Consumers Cooperative (OTEC) offers a commercial lighting retrofit program that provides rebates for commercial businesses that change existing lighting to more energy...

258

Advanced Energy Retrofit Guide (AERG): Practical Ways to Improve Energy Performance; Healthcare Facilities (Book)  

SciTech Connect (OSTI)

The Advanced Energy Retrofit Guide for Healthcare Facilities is part of a series of retrofit guides commissioned by the U.S. Department of Energy. By presenting general project planning guidance as well as detailed descriptions and financial payback metrics for the most important and relevant energy efficiency measures (EEMs), the guides provide a practical roadmap for effectively planning and implementing performance improvements in existing buildings. The Advanced Energy Retrofit Guides (AERGs) are intended to address key segments of the U.S. commercial building stock: retail stores, office buildings, K-12 schools, grocery stores, and healthcare facilities. The guides' general project planning considerations are applicable nationwide; the energy and cost savings estimates for recommended EEMs were developed based on energy simulations and cost estimates for an example hospital tailored to five distinct climate regions. These results can be extrapolated to other U.S. climate zones. Analysis is presented for individual EEMs, and for packages of recommended EEMs for two project types: existing building commissioning projects that apply low-cost and no-cost measures, and whole-building retrofits involving more capital-intensive measures.

Hendron, R.; Leach, M.; Bonnema, E.; Shekhar, D.; Pless, S.

2013-09-01T23:59:59.000Z

259

Emission Control Systems and Components for Retrofit and First...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Systems and Components for Retrofit and First-Fit Applications Emission Control Systems and Components for Retrofit and First-Fit Applications 2004 Diesel Engine Emissions...

260

Retrofit Diesel Emissions Control System Providing 50% NOxControl...  

Broader source: Energy.gov (indexed) [DOE]

Retrofit Diesel Emissions Control System Providing 50% NOxControl Retrofit Diesel Emissions Control System Providing 50% NOxControl 2005 Diesel Engine Emissions Reduction (DEER)...

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active Diesel Particulate Filters Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active Diesel Particulate...

262

Advanced Critical Advanced Energy Retrofit Education and Training...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Critical Advanced Energy Retrofit Education and Training and Credentialing - 2014 BTO Peer Review Advanced Critical Advanced Energy Retrofit Education and Training and...

263

A Methodology to Identify Monthly Energy Use Models from Utility Bill Data for Seasonally Scheduled Buildings: Application to K-12 Schools  

E-Print Network [OSTI]

The measured energy savings from retrofits in buildings is often determined as the difference between the energy consumption predicted by a baseline model and the measured energy consumption during the post retrofit period. Most baseline models...

Wang, W.; Claridge, D. E.; Reddy, T. A.

1998-01-01T23:59:59.000Z

264

Energy Impacts of Energy and Indoor Environmental Quality Retrofits of Apartments in California  

SciTech Connect (OSTI)

Monthly gas and electricity use data from a set of 13 study apartments and 20 control apartments from three apartment buildings (B1 B3) in California were analyzed. The study apartments were retrofit with simultaneous energy savings and indoor environmental quality (IEQ) improvements as the goal. The control apartments were not retrofit. Pre-retrofit modeling indicated annual energy savings of 21percent, 17percent, and 27percent for the study apartments in B1-B3, respectively. Based on a comparison of changes in energy use of study apartments to energy use changes of control apartments, total measured savings of gas energy plus site electrical energy were 28percent in B1, 5percent in B2, and 3percent in B3. Given the small number of study apartments and the substantial changes in energy use within control apartments, the project yielded no conclusive evidence of energy savings. Apartment energy use increased with number of occupants and with floor area; however, the association with occupancy was most evident. Climate differences did not appear to be the major driver for the variability in energy use among apartments. Changes in occupant behaviors affecting energy use may have overwhelmed and obscured the energy savings in this small number of buildings. Much larger prior studies employing similar retrofits indicate that the retrofits usually do save energy.

Fisk, William J.; Norris, Federico; Singer, Brett C.

2013-11-01T23:59:59.000Z

265

BENEFIT Funding Opportunity- Webinar 1  

Broader source: Energy.gov [DOE]

This is webinar 1 for the Building Energy Efficiency Frontiers and Innovation Technologies (BENEFIT) - 2015 Funding Opportunity Announcement (FOA) Number: DE-FOA-0001166.

266

BENEFIT Funding Opportunity- Webinar 2  

Broader source: Energy.gov [DOE]

This is webinar 2 for the Building Energy Efficiency Frontiers and Innovation Technologies (BENEFIT) - 2015 Funding Opportunity Announcement (FOA) Number: DE-FOA-0001166.

267

Building Media, Inc. (Du Pont) (Building America Retrofit Alliance) | Open  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating SolarElectricEnergyCTBarre BiomassTHISBrickyardRepower Jump

268

Retrofit Energy Savings Estimation Model Reference Manual  

E-Print Network [OSTI]

Retrofit Energy Savings Estimation Model Reference Manual #12;#12;Retrofit Energy Savings commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does from the Department of Energy. Any conclusions or opinions expressed in this manual represent solely

269

Green Energy Standards for Public Buildings  

Broader source: Energy.gov [DOE]

In March 2012, West Virginia enacted the Green Buildings Act, which applies to all new construction of public buildings, buildings receiving state grant funds, and buildings receiving state...

270

Expert Meeting Report: Transforming Existing Buildings through New Media--An Idea Exchange  

SciTech Connect (OSTI)

This report describes results of a Building America expert meeting on September 13, 2011, in Las Vegas, Nevada, hosted by the Building America Retrofit Alliance (BARA). This meeting provided a forum for presentations and discussions on the use of new media to work with remodelers and retrofit projects to improve energy efficiency and deliver research results from the Building America program to remodelers.

Hunt, S.

2012-05-01T23:59:59.000Z

271

ORNL Building Technologies Research & Integration Center (BTRIC) New Laboratory Facilities per  

E-Print Network [OSTI]

-level energy efficiency in residential and commercial buildings, new or retrofit. In addition, thanks (partnering with builders on new construction and retrofits) is not feasible for commercial buildings in the space utilization in commercial buildings, which limits the R&D value that can be gained from holding

Oak Ridge National Laboratory

272

Self-Funded Public Facilities Energy Retrofit Programs | Department of  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartment of Energy U.S. DepartmentCommitment for a LoanMarch 14,EnergyTreatment

273

Boston solar retrofits: studies of solar access and economics  

SciTech Connect (OSTI)

Studies of solar access and solar retrofit economics are described for residential applications in the City of Boston. The study of solar access was based upon a random sample of 94 buildings; the sample was stratified to ensure a broad geographic representation from the city's various sections. Using available data on the heights and orientations of the sampled structures and surrounding buildings, each building's hourly access to sunlight was computed separately for the roof and south facing walls. These data were then aggregated by broad structural classifications in order to provide general measures of solar access. The second study was a comparative analysis of the economics of several solar heating and hot water systems. An active hot water system, installed using pre-assembled, commercially purchased equipment, was selected as a reference technology. A variety of measures of economic performance were computed for this system, with and without existing tax credits and under various financing arrangements. Next, a number of alternative approaches for solar space and water heating were identified from interviews with individuals and groups involved in solar retrofit projects in the Boston area. The objective was to identify approaches that many of those interviewed believe to be low-cost means of applying solar energy in residential settings. The approaches selected include thermal window covers, wall collectors, bread box water heaters, and sun spaces. Preliminary estimates of the performance of several representative designs were developed and the economics of these designs evaluated.

Shapiro, M.

1980-11-01T23:59:59.000Z

274

Proven Performance of Seven Cold Climate Deep Retrofit Homes  

SciTech Connect (OSTI)

Seven test homes located in Massachusetts are examined within this report. The retrofit strategies of each home are presented along with a comparison of the pre- and post-retrofit airtightness achieved by the group. Pre- and post-retrofit utility bills were collected; energy models were used to estimate pre-retrofit energy use when bills were unavailable.

Osser, R.; Neuhauser, K.; Ueno, K.

2012-06-01T23:59:59.000Z

275

Improving Building Energy System Performance by Continuous Commissioning  

E-Print Network [OSTI]

data. The first buildings to undergo a continuous commissioning process were in the Texas LoanSTAR program [Liu, et al, 1994, Claridge, et al, 1994]. These buildings had been retrofitted with various energy efficiency improvements, and measured hourly...

Turner, W. D.; Liu, M.; Claridge, D. E.; Haberl, J. S.

1996-01-01T23:59:59.000Z

276

Retrofit Audits and Cost Estimates: A Look at Quality and Consistency  

SciTech Connect (OSTI)

Retrofit NYC Block by Block is an outreach program targeting owners of one- to four-family homes, the most common building type in New York City, with more than 600,000 structures citywide. Administered by the Pratt Center for Community Development and implemented by four nonprofit, community based organizations, Block by Block connects residents, businesses, and religious and civic organizations in predominantly low- and moderate-income neighborhoods with one or more of a half-dozen public and private financial incentive programs that facilitate energy-efficiency retrofits. This research project sought to evaluate the approach, effectiveness, and the energy use reductions accomplished by the Retrofit NYC: Block by Block program.

Eisenberg, L.; Shapiro, C.; Fleischer, W.

2012-10-01T23:59:59.000Z

277

Building on Efficiency | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

easy-to-use tools to size and finance rooftop solar panels; and download virtual energy audit software that can cut costs for building owners and help get retrofits started...

278

Retrofitting CO{sub 2} capture  

SciTech Connect (OSTI)

Retrofitting existing fossil-fueled plants with the first available carbon dioxide capture technologies could play an important role in paving the way for development of lower-cost, reliable carbon capture and storage systems. EPRI research is helping utilities better understand the engineering challenges and economic consequences. Studies are being conducted on retrofitting five different plants with advanced amine PCC technologies. Other studies include: process optimization studies; valuing operating flexibility; CO{sub 2} capture for CTCC plants; and assessing the impact of climate policy on retrofitting investment.

Weisel, J.

2009-07-01T23:59:59.000Z

279

Energy Efficiency Building Code for Commercial Buildings in Sri Lanka  

SciTech Connect (OSTI)

1.1.1 To encourage energy efficient design or retrofit of commercial buildings so that they may be constructed, operated, and maintained in a manner that reduces the use of energy without constraining the building function, the comfort, health, or the productivity of the occupants and with appropriate regard for economic considerations. 1.1.2 To provide criterion and minimum standards for energy efficiency in the design or retrofit of commercial buildings and provide methods for determining compliance with them. 1.1.3 To encourage energy efficient designs that exceed these criterion and minimum standards.

Busch, John; Greenberg, Steve; Rubinstein, Francis; Denver, Andrea; Rawner, Esther; Franconi, Ellen; Huang, Joe; Neils, Danielle

2000-09-30T23:59:59.000Z

280

Retrofitting the Streetlights in Boise, Idaho  

ScienceCinema (OSTI)

Boise, Idaho is using an energy efficiency grant to retrofit hundreds of streetlights throughout the downtown area with energy-efficient LED bulbs, which will save money and improve safety and local quality of life.

Young, Clay; Oliver, LeAnn; Bieter, David; Johnson, Michael; Oldemeyer, Neal

2013-05-29T23:59:59.000Z

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Retrofitting the Streetlights in Boise, Idaho  

Broader source: Energy.gov [DOE]

Boise, Idaho is using an energy efficiency grant to retrofit hundreds of streetlights throughout the downtown area with energy-efficient LED bulbs, which will save money and improve safety and...

282

Application of Pinch Technology in Refinery Retrofits  

E-Print Network [OSTI]

APPLICATION OF PINCH TECHNOLOGY IN REFINERY RETROFITS W. R. L. Thomas, J. H. Siegell, T. Sideropoulos, J. L. Robertson, S. A. Papoulias Exxon Research and Engineering Company Florham Park, New Jersey ABSTRACT This paper reviews... the application of pinch technology in the identification of the most attractive retrofit prospects in typical refineries. In the first part of the paper, methodology is described to identify attractive inter-unit heat integration opportunities as well...

Thomas, W. R.; Siegell, J. H.; Sideropoulos, T.; Robertson, J. L.; Papoulias, S. A.

283

Cold Climate Foundation Retrofit Energy Savings: The Simulated Energy and Experimental Hygrothermal Performance of Cold Climate Foundation Wall Insulation Retrofit Measures -- Phase I, Energy Simulation  

SciTech Connect (OSTI)

A split simulation whole building energy/3-dimensional earth contact model (termed the BUFETS/EnergyPlus Model or BEM) capable of modeling the full range of foundation systems found in the target retrofit housing stock has been extensively tested. These foundation systems that include abovegrade foundation walls, diabatic floors or slabs as well as lookout or walkout walls, currently cannot be modeled within BEopt.

Goldberg, L. F.; Steigauf, B.

2013-04-01T23:59:59.000Z

284

Evaluation of passive solar retrofit options  

SciTech Connect (OSTI)

An evaluation framework has been developed which allows for the assessment of the role of passive solar retrofit in the nationwide reduction of conventional fuel use. Three types of analysis are proposed within this framework: the physical/technical capability of the present housing stock to incorporate passive solar retrofit; the economic feasibility of the application of retrofit designs; and the actual market potential or acceptance of these alternative retrofit options. Each type of analysis has specific data requirements and a series of evaluation procedures to help establish estimates of the potential for passive solar retrofit in the present housing stock. The data requirements with their respective sources and evaluation procedures for the first two types of analysis-physical/technical setting and economic feasibility, are examined. A distinction is drawn between community specific case studies and more generalized national assessments. Information derived from these three types of analysis, whether case specific or national in scope, can then be used in an evaluation of potential economic impacts. The establishment of regional economic benefits and costs werve as a measure of the merit or attractiveness of the implementation of a passive solar retrofit program.

Ben-David, S.; Kirchemen, C.; Martin, S.; Noll, S.; Roach, F.

1980-01-01T23:59:59.000Z

285

Concrete Masonry Wall Retrofit Systems for Blast Protection  

E-Print Network [OSTI]

. The experimental program used to evaluate the alternative retrofit systems was divided into three phases. In Phase one, resistance functions for seven different retrofit systems were developed in 24 subscale static experiments. In Phase two, the structural response...

Johnson, Carol Faye

2013-12-11T23:59:59.000Z

286

Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics  

E-Print Network [OSTI]

Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate...

Graham, E. L.

1980-01-01T23:59:59.000Z

287

DOE Webinar ? Residential Geothermal Heat Pump Retrofits (Presentation)  

Broader source: Energy.gov [DOE]

DOE webinar, Residential Geothermal Heat Pump Retrofits presented at the DOE EERE Webinar Series on Dec. 14, 2010.

288

NREL Job Task Analysis: Retrofit Installer Technician (Revised)  

SciTech Connect (OSTI)

A summary of job task analyses for the position of retrofit installer technician when conducting weatherization work on a residence.

Kurnik, C.; Woodley, C.

2012-04-01T23:59:59.000Z

289

Starting a local conservation and passive solar retrofit program: an energy planning sourcebook  

SciTech Connect (OSTI)

A city planner or a neighborhood activist may wish to initiate a local conservation and passive solar retrofit program but may not have previous experience in doing so. This sourcebook is designed to assist interested individuals with their energy planning efforts, from determining retrofit potential, to financing and implementing the program. An approach or methodology is provided which can be applied to determine retrofit potential in single-family residences, mobile homes, multifamily residences, and nonresidential buildings. Case studies in Albuquerque, New Mexico, are given as examples. Guidelines are provided for evaluating the economic benefits of a retrofit program through benefit-cost analysis and economic base studies at the city and neighborhood levels. Also included are approaches to community outreach, detailing how to get started, how to gain local support, and examples of successful programs throughout the US. The need for financing, the development of a local strategy, public and private financing techniques, and community energy service organizations are examined. In addition to the Albuquerque case studies, a brief technology characterization, heat-loss calculations, economic tools, and a list of resources are appended.

Barber, V; Mathews, R

1982-02-01T23:59:59.000Z

290

Microcomputer Energy Analysis Studies of Selected Building Types in a Hot, Humid Climatic Zone  

E-Print Network [OSTI]

The DOE-2 building energy analysis computer program has been used in both the design and analysis of new or retrofitted buildings. The combination of ease of use, economy, and the capability of producing a comprehensive thermal analysis has made...

McQueen, T. M.; Leaver, J. F.

1986-01-01T23:59:59.000Z

291

Daylight Analysis with Microcomputers for School Buildings in a Hot, Humid Climate  

E-Print Network [OSTI]

Daylighting and other passive energy technologies are critical issues that should be considered in the early stages of building planning and architectural design. Both new design and retrofit of existing buildings benefit greatly by use...

Leaver, J.; McQueen, T.

1987-01-01T23:59:59.000Z

292

Bridgeview Park facility solar retrofit  

SciTech Connect (OSTI)

The weatherization and insulation of a presently unheated frame park building and the installation of a Trombe wall on the south side of the structure for passive solar heating are planned. The major objectives of the project are to increase the exposure of local residents and visitors to passive solar technology and to demonstrate the applicability of passive solar technology to residential, commercial and recreational buildings. Some changes in the original plans are discussed. Five blueprints illustrate the planned improvements. (LEW)

Not Available

1981-01-01T23:59:59.000Z

293

Interactions between Energy Efficiency Programs funded under the Recovery Act and Utility Customer-Funded Energy Efficiency Programs  

E-Print Network [OSTI]

of transforming energy efficiency markets into more self-3. SEP funding for building energy efficiency by marketfor buildings energy efficiency by market sector Less

Goldman, Charles A.

2011-01-01T23:59:59.000Z

294

Development and Application of a Procedure to Estimate Overall Building and Ventilation Parameters from Monitored Commercial Building Energy Use  

E-Print Network [OSTI]

for CV system, VAV system and building load. 59 5.3 Monthly EDE for CV system, VAV system and building load 61 5.4 Monthly MEIc and MEIh for CV system, VAV system and building load.... 61 XU FIGURE Page 5.5 Multistep regression results with monitored... for for the BUS building pre and post retrofit 71 5.9 Monthly MEIc and MEIh for the BUS building pre and post retrofit 71 . 5.10 Monthly outdoor dry-bulb temperature and relative humidity conditions under which the HVAC systems were analyzed for the CSB building...

Deng, Song

295

Actual and Estimated Energy Savings Comparison for Deep Energy Retrofits in the Pacific Northwest  

SciTech Connect (OSTI)

Seven homes from the Pacific Northwest were selected to evaluate the differences between estimated and actual energy savings achieved from deep energy retrofits. The energy savings resulting from these retrofits were estimated, using energy modeling software, to save at least 30% on a whole-house basis. The modeled pre-retrofit energy use was trued against monthly utility bills. After the retrofits were completed, each of the homes was extensively monitored, with the exception of one home which was monitored pre-retrofit. This work is being conducted by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy Building Technologies Program as part of the Building America Program. This work found many discrepancies between actual and estimated energy savings and identified the potential causes for the discrepancies. The differences between actual energy use and modeled energy use also suggest improvements to improve model accuracy. The difference between monthly whole-house actual and estimated energy savings ranged from 75% more energy saved than predicted by the model to 16% less energy saved for all the monitored homes. Similarly, the annual energy savings difference was between 36% and -14%, which was estimated based on existing monitored savings because an entire year of data is not available. Thus, on average, for all six monitored homes the actual energy use is consistently less than estimates, indicating home owners are saving more energy than estimated. The average estimated savings for the eight month monitoring period is 43%, compared to an estimated savings average of 31%. Though this average difference is only 12%, the range of inaccuracies found for specific end-uses is far greater and are the values used to directly estimate energy savings from specific retrofits. Specifically, the monthly post-retrofit energy use differences for specific end-uses (i.e., heating, cooling, hot water, appliances, etc.) ranged from 131% under-predicted to 77% over-predicted by the model with respect to monitored energy use. Many of the discrepancies were associated with occupant behavior which influences energy use, dramatically in some cases, actual versus modeled weather differences, modeling input limitations, and complex homes that are difficult to model. The discrepancy between actual and estimated energy use indicates a need for better modeling tools and assumptions. Despite the best efforts of researchers, the estimated energy savings are too inaccurate to determine reliable paybacks for retrofit projects. While the monitored data allows researchers to understand why these differences exist, it is not cost effective to monitor each home with the level of detail presented here. Therefore an appropriate balance between modeling and monitoring must be determined for more widespread application in retrofit programs and the home performance industry. Recommendations to address these deficiencies include: (1) improved tuning process for pre-retrofit energy use, which currently utilized broad-based monthly utility bills; (2) developing simple occupant-based energy models that better address the many different occupant types and their impact on energy use; (3) incorporating actual weather inputs to increase accuracy of the tuning process, which uses utility bills from specific time period; and (4) developing simple, cost-effective monitoring solutions for improved model tuning.

Blanchard, Jeremy; Widder, Sarah H.; Giever, Elisabeth L.; Baechler, Michael C.

2012-10-01T23:59:59.000Z

296

Building America Expert Meeting: Multifamily Hydronic and Steam...  

Broader source: Energy.gov (indexed) [DOE]

was cost-effective controls and distribution retrofit options for hot water and steam space heating systems in multi-family buildings with the goals of reducing energy waste and...

297

Building America Efficient Solutions for Existing Homes: Case...  

Energy Savers [EERE]

Texas PNNL, FSEC, and CalcsPlus provided technical assistance to Build San Antonio Green on three deep energy retrofits. For this gut rehab they replaced the old roof with a...

298

Design and thermal modeling of a residential building  

E-Print Network [OSTI]

Recent trends of green energy upgrade in commercial buildings show promise for application to residential houses as well, where there are potential energy-saving benefits of retrofitting the residential heating system from ...

Yeh, Alice Su-Chin

2009-01-01T23:59:59.000Z

299

Cost-Effectiveness of Home Energy Retrofits in Pre-Code Vintage Homes in the United States  

SciTech Connect (OSTI)

This analytical study examines the opportunities for cost-effective energy efficiency and renewable energy retrofits in residential archetypes constructed prior to 1980 (Pre-Code) in fourteen U.S. cities. These fourteen cities are representative of each of the International Energy Conservation Code (IECC) climate zones in the contiguous U.S. The analysis is conducted using an in-house version of EnergyGauge USA v.2.8.05 named CostOpt that has been programmed to perform iterative, incremental economic optimization on a large list of residential energy efficiency and renewable energy retrofit measures. The principle objectives of the study are as follows: to determine the opportunities for cost effective source energy reductions in this large cohort of existing residential building stock as a function of local climate and energy costs; and to examine how retrofit financing alternatives impact the source energy reductions that are cost effectively achievable.

Fairey, P.; Parker, D.

2012-11-01T23:59:59.000Z

300

ARRA Proposed Award: Retrofit Bay Area  

E-Print Network [OSTI]

ARRA Proposed Award: Retrofit Bay Area Counties of Alameda, Contra Costa, Marin, San Francisco per year Prime contractor: Association of Bay Area Governments (ABAG) Sub contractors: Alameda County Waste Management Authority (StopWaste.org) County of Contra Costa County of Marin City

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Retrofiting survivability of military vehicles  

SciTech Connect (OSTI)

In Iraq the terrain was such that vehicles could be distributed horizontally, which reduced the effectiveness of mines. In the mountainous terrain of Pakistan and Afghanistan vehicles are forced to use the few, passable roads, which are dirt and easily seeded with plentiful, cheap, intelligent mines. It is desirable to reduce the losses to such mines, preferably by retrofit means that do not greatly increase weight or cost or reduce maneuverability. V-bottom vehicles - A known approach to reducing vulnerability is the Buffalo, a large vehicle developed by South Africa to address mine warfare. It has large tires, high axles, and a reinforced, v-shaped bottom that deflects the blast from explosions below. It is developed and tested in combat, but is expensive and has reduced off-road mobility. The domestic MRAP has similar cost and mobility issue. The addition of v-shaped blast deflectors to vehicles such as Humvees could act much as the deflector on a Buffalo, but a Humvee is closer to the ground, so the explosive's expansion would be reduced. The deflector would also reduce a Humvee's clearance for rough terrain, and a deflector of adequate thickness to address the blast by itself could further increase cost and reduce mobility. Reactive armor is developed and has proven effective against shaped and explosive charges from side or top attack. It detects their approach, detonates, and defeats them by interfering with jet formation. If the threat was a shaped charge from below, they would be a logical choice. But the bulk of the damage to Humvees appears to be from the blast from high explosive mines for which the colliding shock from reactive armor could increase that from the explosive. Porous materials such as sand can strongly attenuate the kinetic energy and pressure of a strong shock. Figure 1 shows the kinetic energy (KE), momentum (Mu), velocity (u), and mass (M) of a spherically expanding shock as functions of radius for a material with a porosity of 0.5. Over the range from 0.5 to 4.5 cm the shock KE is attenuated by a factor of {approx}70, while its momentum is changed little. The shock and particle velocity falls by a factor of 200 while the mass increases by a factor of 730. In the limit of very porous media u {approx} 1/M, so KE {approx} 1/M, which falls by a factor of {approx}600, while momentum Mu does not change at all. Figure 2 shows the KE, Mu, u, and M for a material with a porosity of 1.05, for which the KE changes little. In the limit of media of very low porosity, u {approx} 1/{radical}M, so KE is constant while Mu {approx} {radical}M, which increases by a factor of 15. Thus, if the goal is to reduce the peak pressure from strong explosions below, very porous materials, which strongly reduce pressure but do not increase momentum, are preferred to non-porous materials, which amplify momentum but do not decrease pressure. These predictions are in qualitative accord with the results of experiments at Los Alamos in which projectiles from high velocity, large caliber cannons were stopped by one to two sandbags. The studies were performed primarily to determine the effectiveness of sand in stopping fragments of various sizes, but could be extended to study sand's effectiveness in attenuating blast pressure. It would also be useful to test the above predictions on the effectiveness of media with higher porosity. Water barriers have been discussed but not deployed in previous retrofit survivability studies for overseas embassies. They would detect the flash from the mine detonation below, trigger a thin layer of explosive above a layer of water, and drive water droplets into the approaching blast wave. The blast loses energy in evaporating the droplets and loses momentum in slowing them. Under favorable conditions that could attenuate the pressure in the blast enough to prevent the penetration or disruption of the vehicle. However, such barriers would depend on prompt and reliable detonation detection and water droplet dispersal, which have not been tested. There is a large literature on the theoretical effec

Canavan, Gregory H [Los Alamos National Laboratory

2009-01-01T23:59:59.000Z

302

Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance, K-12 Schools (Book)  

SciTech Connect (OSTI)

The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited. Instead, we emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluations of the most promising retrofit energy efficiency measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. K-12 schools were selected as one of the highest priority building sectors, because schools affect the lives of most Americans. They also represent approximately 8% of the energy use and 10% of the floor area in commercial buildings nationwide. U.S. K-12 school districts spend more than $8 billion each year on energy - more than they spend on computers and textbooks combined. Most occupy older buildings that often have poor operational performance - more than 30% of schools were built before 1960. The average age of a school is about 42 years - which is nearly the expected serviceable lifespan of the building. K-12 schools offer unique opportunities for deep, cost-effective energy efficiency improvements, and this guide provides convenient and practical guidance for exploiting these opportunities in the context of public, private, and parochial schools.

Not Available

2013-12-01T23:59:59.000Z

303

CX-001553: Categorical Exclusion Determination | Department of...  

Broader source: Energy.gov (indexed) [DOE]

Grant Fund (EECBG). Residential Energy Efficiency Improvements, Commercial Building Retrofit Program, Energy Efficiency Lighting Replacement - Multiple Facilities, Old City Hall...

304

Byggmeister Test Home: Analysis and Initial Results of Cold Climate Wood-Framed Home Retrofit  

SciTech Connect (OSTI)

BSC seeks to further the energy efficiency market for New England area retrofit projects by supporting projects that are based on solid building science fundamentals and verified implementation. With the high exposure of energy efficiency and retrofit terminology being used in the general media at this time, it is important to have evidence that measures being proposed will in fact benefit the homeowner through a combination of energy savings, improved durability, and occupant comfort. There are several basic areas of research to which the technical report for these test homes can be expected to contribute. These include the combination of measures that is feasible, affordable and acceptable to homeowners as well as expectations versus results. Two Byggmeister multi-family test homes in Massachusetts are examined with the goal of providing case studies that could be applied to other similar New England homes.

Gates, C.

2013-01-01T23:59:59.000Z

305

Predicted Versus Actual Savings for a Low-Rise Multifamily Retrofit in Boulder, Colorado  

SciTech Connect (OSTI)

To determine the most cost-effective methods of improving buildings, accurate analysis and prediction of the energy use of existing buildings is essential. However, multiple studies confirm that analysis methods tend to over-predict energy use in poorly insulated, leaky homes and thus, the savings associated with improving those homes. In NREL's report titled 'Assessing and Improving the Accuracy of Energy Analysis of Residential Buildings,' researchers propose a method for improving the accuracy of residential energy analysis methods. A key step in this process involves the comparisons of predicted versus metered energy use and savings. In support of this research need, CARB evaluated the retrofit of a multifamily building in Boulder, CO. The updated property is a 37 unit, 2 story apartment complex built in 1950, which underwent renovations in early 2009 to bring it into compliance with Boulder, CO's SmartRegs ordinance. Goals of the study were to: 1) evaluate predicted versus actual savings due to the improvements, 2) identify areas where the modeling assumptions may need to be changed, and 3) determine common changes made by renters that would negatively impact energy savings. In this study, CARB seeks to improve the accuracy of modeling software while assessing retrofit measures to specifically determine which are most effective for large multifamily complexes in the cold climate region. Other issues that were investigated include the effects of improving building efficiency on tenant comfort, the impact on tenant turnover rates, and the potential market barriers for this type of community scale project.

Arena, L.; Williamson, J.

2013-11-01T23:59:59.000Z

306

Extremely Low-Energy Design for Army Buildings: Tactical Equipment Maintenance Facility; Preprint  

SciTech Connect (OSTI)

This paper describes the integrated energy optimization process for buildings and building clusters and demonstrates this process for new construction projects and building retrofits. An explanation is given of how mission critical building loads affect possible site and source energy use reduction in Army buildings.

Langner, R.; Deru, M.; Zhivov, A.; Liesen, R.; Herron, D.

2012-03-01T23:59:59.000Z

307

Retrofit Analysis of HVAC Systems Using Artificial Neural Networks.  

E-Print Network [OSTI]

??This thesis aims to explore the benefits of retrofits applied to the compressor and burner in the AC and furnace respectively and how best to… (more)

Anand, Anish

2014-01-01T23:59:59.000Z

308

Residential photovoltaic worth : an assessment of retrofit vs. new construction  

E-Print Network [OSTI]

This paper characterizes the basic differences between photovoltaic retrofit and new construction applications. It quantifies the tradeoffs forced by rooftop area constraints, special array mounting costs, maintenance ...

Dinwoodie, Thomas L.

1982-01-01T23:59:59.000Z

309

Retrofit Diesel Emissions Control System Providing 50% NOxControl  

Broader source: Energy.gov (indexed) [DOE]

LNT regeneration Minimal LNT volume Easy Retrofit Application: No modification to engine No engine control required Bolt-on design replaces existing muffler time Target: EPA...

310

Comparison of Home Retrofit Programs in Wisconsin  

SciTech Connect (OSTI)

To explore ways to reduce customer barriers and increase home retrofit completions, several different existing home retrofit models have been implemented in the state of Wisconsin. This study compared these programs' performance in terms of savings per home and program cost per home to assess the relative cost-effectiveness of each program design. However, given the many variations in these different programs, it is difficult to establish a fair comparison based on only a small number of metrics. Therefore, the overall purpose of the study is to document these programs' performance in a case study approach to look at general patterns of these metrics and other variables within the context of each program. This information can be used by energy efficiency program administrators and implementers to inform home retrofit program design. Six different program designs offered in Wisconsin for single-family energy efficiency improvements were included in the study. For each program, the research team provided information about the programs' approach and goals, characteristics, achievements and performance. The program models were then compared with performance results -- program cost and energy savings -- to help understand the overall strengths and weaknesses or challenges of each model.

Cunningham, K.; Hannigan, E.

2013-03-01T23:59:59.000Z

311

Funding Opportunity Webinar- University R&D Teams  

Broader source: Energy.gov [DOE]

The Building Technologies Office (BTO)’s Emerging Technologies Program has announced the availability of up to $1 million for the Buildings University Innovators and Leaders Development (BUILD) Funding Opportunity Announcement (FOA) DE-FOA-0001167.

312

Analysis of Pre-Retrofit Building and Utility Data  

Office of Scientific and Technical Information (OSTI)

at www.osti.govbridge Available for a processing fee to U.S. Department of Energy and its contractors, in paper, from: U.S. Department of Energy Office of Scientific...

313

Residential Building Audits and Retrofits (Text Version) | Department...  

Broader source: Energy.gov (indexed) [DOE]

that sort. And during that part, I discovered there were 1200 parts per million of carbon monoxide being produced by this furnace. Some sort of problem there, and incomplete flame...

314

An Overview of the Building Energy Retrofit Research Program  

E-Print Network [OSTI]

Ridge National Labora- tory (ORNL) and multi-family (MF) research led by Lawrence Berkeley Laboratory. Other participants include Princeton University, the Solar Energy Research Institute, the Alliance to Save Energy (ASE), and Pacific Northwest.... The ORNL experiments on radiant barriers were conducted in three unoccupied houses. One was used as the control house with no barrier, while the other two houses were used to test two different methods for installing radiant barriers. In one house...

Mixon, W. R.

1987-01-01T23:59:59.000Z

315

Chapter 8, Whole-Building Retrofit with Billing Analysis Evaluation...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

activity. For example, if 5% of a population would have installed an energy-efficient furnace without rebate assistance, then the same percentage of both the treatment and...

316

Business Case for Energy Efficient Building Retrofit and Renovation  

Energy Savers [EERE]

& Analytics Burleigh Morton Director, Partnerships & Alliances John Gudgel Director, Green Content & Research Communications Michele A. Russo, LEED AP Business Case for Energy...

317

Building America Best Practices Series, Vol. 10 - Retrofit Techniques &  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top Five EEREDepartmentFebruary 4,Brent Nelson About2014 HouseTechnologies: Air

318

Building America Expert Meeting: Interior Insulation Retrofit of Mass  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top Five EEREDepartmentFebruary 4,Brent NelsonEvaluationHomesField Performance

319

Building America Expert Meeting: Retrofit Implementation - A Neighborhood  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top Five EEREDepartmentFebruary 4,Brent NelsonEvaluationHomesFieldManagementininat

320

Building Retrofit and DSM Study in Jiangsu | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartmentAUDIT REPORTOpenWendeGuo FengBoulder, CO) JumpNRELEnergyGHGs

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Building Retrofit and DSM Study in Jiangsu | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating SolarElectricEnergyCTBarre BiomassTHISBrickyardRepower Jump

322

Energy Innovation Hub Report Shows Philadelphia-area Building Retrofits  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPC ENABLE:2009 DOEDeploymentHenry C. FoleyEnergy FromCould Support

323

Building America Technology Solutions for New and Existing Homes: Retrofit  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists' ResearchTheMarketing,Energy andNewsBuildingandCeiling Interior Duct System,Integrated

324

Building America Webinar: A National Summary of Deep Energy Retrofits |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 < prev next >research teamhave found

325

Building America Webinar: Deep Energy Retrofit Case Studies: Lessons  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 < prev next >research teamhaveDepartment

326

Building America Webinar: Results from Phased Deep Retrofits in Florida |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 < prev next >researchNew

327

BetterBuildings Financing Energy Efficiency Retrofits in the Commercial  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd: ScopeDepartment1, 2011 DRAFT ADVANCEDOutreach ThroughiT

328

Development and application of a procedure to estimate overall building and ventilation parameters from monitored commercial building energy use  

E-Print Network [OSTI]

systems were analyzed for the BUS building. . . . . . . . . . 69 5. 7 Monthly average of energy use for the BUS building pre and post retrofit. . . . 69 5. 8 Monthly EDE for for the BUS building pre and post retrofit. . . . 71 5. 9 Monthly MEIc and MEIh... of energy use for the CSB pre and post continuous commissioning. . 74 5. 12 Monthly EDE for for the CSB building pre and post continuous commissioning. . 77 5. 13 Monthly MEIc and MEIh for the CSB pre and post continuous commissioning. . 77 LIST...

Deng, Song Jiu

1997-01-01T23:59:59.000Z

329

The Future of Technical Assistance, Funding and Finding Alternatives  

E-Print Network [OSTI]

? Tools ? Local and individual technical support ? Budget analysis for operations and maintenance ? Cost analysis and management ? Financial alternatives ? Grant writing ? Construction and retrofit alternatives ? Back office Putting an energy...The Future of Technical Assistance, Funding and Financing Alternatives Rich Oliver, McKinstry More ?no cost or at risk? assistance in Texas than ever before ? Mentoring by Private Sector ? Education and outreach services ? Documents...

Oliver, R.

2011-01-01T23:59:59.000Z

330

PROGRESS IN ENERGY EFFICIENT BUILDINGS  

SciTech Connect (OSTI)

Recent accomplishments in buildings energy research by the diverse groups in the Energy Efficient Buildings Program at Lawrence Berkeley Laboratory (LBL) are summarized. We review technological progress in the areas of ventilation and indoor air quality, buildings energy performance, computer modeling, windows, and artificial lighting. The need for actual consumption data to track accurately the improving energy efficiency of buildings is being addressed by the Buildings Energy Data (BED) Group at LBL. We summarize results to date from our Building Energy Use Compilation and Analysis (BECA) studies, which include time trends in the energy consumption of new commercial and new residential buildings, the measured savings being attained by both commercial and residential retrofits, and the cost-effectiveness of buildings energy conservation measures. We also examine recent comparisons of predicted vs. actual energy usage/savings, and present the case for building energy use labels.

Wall, L.W.; Rosenfeld, A.H.

1982-12-01T23:59:59.000Z

331

2013 Reinvention Fund Request for Proposals 1 2013 Reinvention Fund: Request for Proposals  

E-Print Network [OSTI]

2013 Reinvention Fund Request for Proposals 1 2013 Reinvention Fund: Request for Proposals Building a Living Laboratory for Sustainability at Penn State Reinvention Fund Projects Pre-Proposals Due: October 21, 2013 Full Proposals Due: December 20, 2013 Student Sustainability Innovation Projects Pre

Maranas, Costas

332

Measure Guideline: Hybrid Foundation Insulation Retrofits  

SciTech Connect (OSTI)

This measure guideline provides recommendations for designs and variations for retrofit hybrid assemblies in improving interior foundation insulation and water management of basements. Variations include closed cell spray foam (ccSPF) with membrane waterproofing or air gap membrane drainage layers, rigid board foam insulation at flat walls (cast concrete or CMU block), a 'partial drainage' detail making use of the bulk water drainage that occurs through the field of a rubble stone wall, and non-drained spray foam assemblies (including slab insulation).

Ueno, K.; Lstiburek, J.

2012-05-01T23:59:59.000Z

333

Trial Demonstration of Area Lighting Retrofit  

Broader source: Energy.gov [DOE]

LED Area Lighting Retrofit: Yuma Border Patrol Along the Yuma Sector Border Patrol Area in Yuma, Arizona, the GATEWAY program conducted a trial demonstration in which the incumbent quartz metal halide area lighting was replaced with LED at three pole locations. The LED system was found to equal or better the incumbent system in terms of both illuminance and uniformity, and an advanced optical system and lower pole height improved the illuminance uniformity, reduced stray light, and increased projected energy and maintenance cost savings. This high luminous flux and high temperature application is not unique and similar applications can benefit from the findings of this installation.

334

Cost-effective Lighting Retrofits: Lessons Learned  

E-Print Network [OSTI]

maintained 44 61 96 37 58 % 34 57 % Mean maintained % = 59% The small office room depicted below aluminum full reflector was installed with the same contained one 2'x 4' lay-in deep cell parabolic T-8 lamps. Results are presented in the graph louver... accurate wattage values in calculating predicted savings from a lighting retrofit. Published ANSI values are not an accurate approximation of real world fixture wattage. Field testing within a 2' x 4' lay-in deep cell parabolic louver fixture produced...

Fisher, M. D.

1994-01-01T23:59:59.000Z

335

Retrofitting Doors on Open Refrigerated Cases  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l LPROJECTS IN RENEWABLEOperated in Steady-StateRetrofitting Doors on Open

336

Proposition 39 Implementation Program Funding Allocation for Energy Projects Majority of  

E-Print Network [OSTI]

will help ensure greater long-term energy savings and additional job creation, the Program: · Allows smallProposition 39 Implementation Program ­ Funding Allocation for Energy Projects Majority) $15,000 for LEAs with 100 or less ADA, plus FRPM To support deeper energy retrofit projects which

337

Designing Effective Incentives to Drive Residential Retrofit Program Participation (Text Version)  

Broader source: Energy.gov [DOE]

Transcript of the webinar, "Designing Effective Incentives to Drive Residential Retrofit Program Participation."

338

Practical Alternative Financing Strategies for Building Commissioning  

E-Print Network [OSTI]

Practical Alternative Financing Strategies for Building Commissioning Arun Jhaveri, Regional Manager Federal Energy Management Program U. S. Dept. of Energy/Western Regional Office Seattle, Washington ABSTRACT Owning and operating a... or retro-commissioning of existing buildings/facilities that are going through major retrofit/renovation. In a recent study of some 60 commercial buildings, the Portland Energy Conservation, Inc.(PECI) found the following alarming conditions - i) more...

Zhaveri, A.

2005-01-01T23:59:59.000Z

339

The Business and Technical Case for Continuous Commissioning for Enhanced Building Operations  

E-Print Network [OSTI]

problems, improve comfort, optimize energy use, and identify retrofits in existing commercial and institutional buildings, and central plant facilities. It is also known as retro-commissioning. A summary of the Energy Systems Laboratory (ESL) experience...

Verdict, M.

2006-01-01T23:59:59.000Z

340

Analysis of the Potential Energy Savings for 14 Office Buildings with VAV Systems  

E-Print Network [OSTI]

At the beginning of an existing building commissioning (EBCx)/energy retrofit project, some form of screening is usually applied to determine whether there is sufficient potential for savings to justify a formal EBCx assessment/energy audit...

Claridge, D. E.; Liu, J.; Baltazar, J. C.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Better Buildings Alliance, Advanced Rooftop Unit Campaign: Rooftop Unit Measurement and Verification (Fact Sheet)  

SciTech Connect (OSTI)

This document provides facility managers and building owners an introduction to measurement and verification (M&V) methods to estimate energy and cost savings of rooftop units replacement or retrofit projects to estimate paybacks or to justify future projects.

Not Available

2014-09-01T23:59:59.000Z

342

Requested Funding Categories  

E-Print Network [OSTI]

Requested Funding Categories: Department's Funding Priority Request (in the event partial funding is granted): Committee recommends the following funding: Wages for adjunct or part- time faculty or admin Factors: Has unit received previous internship grant funding? _______ ifso

Martinez, Tony R.

343

Construction and startup experience for Milliken FGD Retrofit Project  

SciTech Connect (OSTI)

Under Round 4 of the U.S. Department of Energy`s Clean Coal Technology program, New York State Electric & Gas Corp. (NYSEG), in partnership with Saarbereg-Stebbins Engineering and Manufacturing Company, has retrofitted a formic acid enhanced forced oxidation wet limestone scrubber on Units 1 & 2 at the Milliken Steam Electric Station. Units 1 & 2 are 1950`s vintage Combustion Engineering tangentially fired pulverized coal units which are rated at nominal 150 MW each and operate in balanced draft mode. The FGD system for Unit 2 was placed into operation in January 1995 and the Unit 1 system in June, 1995. The project incorporates several unique aspects including low pH operation, a ceramic tile-lined cocurrent/countercurrent, split module absorber, a wet stack supported on the roof of the FGD building, and closed loop, zero liquid discharge operation producing commercial grade gypsum, and calcium chloride brine. The project objectives include 98% SO{sub 2} removal efficiency while burning high sulfur coal, the production of marketable byproducts to minimize solid waste disposal, zero wastewater discharge and space-saving design. The paper provides a brief overview of the project design, discusses construction and startup issues and presents early operating results. Process capital cost and economics of this design, procure and construct approach are reviewed relative to competing technologies.

Harvilla, J.; Mahlmeister, M. [New York State Electric and Gas Corp., Binghamton, NY (United States); Buchanan, T.; Jackson, C. [Parsons Power Group, Inc., Reading, PA (United States); Watts, J. [USDOE, Pittsburgh Energy Technology Center, PA (United States)

1996-12-01T23:59:59.000Z

344

Energy Implications of Retrofitting Retail Sector Rooftop Units with Stepped-Speed and Variable-Speed Functionality  

SciTech Connect (OSTI)

Commercial retailers understand that retrofitting constant-speed RTU fan motors with stepped- or variable-speed alternatives could save significant energy in most U.S. climate zones. However, they lack supporting data, both real-world and simulation based, on the cost effectiveness and climate zone-specific energy savings associated with this measure. Thus, building managers and engineers have been unable to present a compelling business case for fan motor upgrades to upper management. This study uses whole-building energy simulation to estimate the energy impact of this type of measure so retailers can determine its economic feasibility.

Studer, D.; Romero, R.; Herrmann, L.; Benne, K.

2012-04-01T23:59:59.000Z

345

Roof and Attic Design Guidelines for new and retrofit Construction of Homes in Hot and Coild Climates  

SciTech Connect (OSTI)

Some guidelines for improving the energy efficiency of roofs and attics are presented and are based on the research of the DOE Building Technology. The results of combined analytical and experimental studies were used to benchmark computer tools, which in turn, were used to simulate homes in hot and cold climates. Adding floor and roof insulation, above deck ventilation, radiant barriers, cool color shingle, metal or tile roofs, sealing the attic floor, sealing the duct system and sealing the attic were simulated to compute the cost of energy savings. Results are prioritized to help building owners make an informed economic decision when contemplating roof and attic retrofits. Sealing the attic floor is a top retrofit option. The sealed attic approach and a new prototype roof assembly an insulated and ventilated roof are good options for retrofit work but have paybacks ranging from 15 to 25 years. A new sealed attic concept was simulated and computations show its simple payback is about 10 to 12 years in hot and cold climates; its first cost is significantly reduced from that of a spray foam approach. For new construction the best option is to keep the ducts out of the attic, make sure the attic floor is sealed and add at least code level of insulation to the ceiling.

Desjarlais, Andre Omer [ORNL] [ORNL; LaFrance, Marc [International Energy Agency] [International Energy Agency

2013-01-01T23:59:59.000Z

346

Building commissioning: The key to quality assurance  

SciTech Connect (OSTI)

This Guide is written to aid building owners and retrofit project managers currently participating in the Rebuild America program. The Guide provides information on implementing building commissioning projects that will optimize the results of existing building equipment improvements and retrofits projects. It should be used in coordination with Rebuild America`s Community Partnership Handbook. The Handbook describes, in detail, eight important steps necessary for planning and carrying out a community-wide energy-efficiency program. In step number 7 of the Handbook, commissioning is shown to be an integral aspect of implementing a building retrofit. The commissioning process ensures that a facility is safe, efficient, comfortable, and conducive to the presumed activities for which it was constructed. Rebuild America strongly encourages its partners to incorporate commissioning into their retrofit projects. By verifying the correct installation, functioning, operation, and maintenance of equipment, the commissioning process ensures that efficiency measures will continue to deliver benefits over the long term. Although commissioning can take place after the equipment has been installed, it is more effective when it takes place over the entire equipment installation process.

NONE

1998-05-01T23:59:59.000Z

347

Efficiency Vermont's Enhanced Building Operations Programs  

E-Print Network [OSTI]

assistance, economic analysis, and financial incentives to help Vermont households and businesses reduce their energy costs 4 Efficiency Vermont?s Commercial & Industrial Programs New Construction Program ? Prescriptive - Rebates ? Core Performance... ? Custom Market Opportunity Program ? Prescriptive - Rebates ? Custom Retrofit Program ? Custom* * includes improving building operations programs More Information at www.efficiencyvermont.com 5 Efficiency Vermont?s Operational Improvement...

Laflamme, S.

2011-01-01T23:59:59.000Z

348

Alternative Refrigerants for Building Air Conditioning  

E-Print Network [OSTI]

The majority of building air conditioning has traditionally been achieved with vapor compression technology using CFC-I I or HCFC-22 as refrigerant fluids. CFC-11 is being successfully replaced by HCFC-123 (retrofit or new equipment) or by HFC- 134a...

Bivens, D. B.

1996-01-01T23:59:59.000Z

349

BENEFIT 2015 Funding Opportunity Announcement Webinar 1 (Text Version)  

Broader source: Energy.gov [DOE]

Below is the text version of the webinar, BENEFIT 2015 Funding Opportunity Announcement, presented in October 2014 by Antonio Bouza, technology manager, and Pat Phelan, program manager, Building...

350

Funding for Small Business Innovation Research in Energy Efficiency...  

Broader source: Energy.gov (indexed) [DOE]

advanced manufacturing, energy-efficient buildings, biomass, hydrogen and fuel cells, solar energy, and wind and water power technologies. The Energy Department will fund...

351

New York City- Green Building Requirements for Municipal Buildings  

Broader source: Energy.gov [DOE]

In 2005 New York City passed a law (Local Law No. 86) making a variety of green building and energy efficiency requirements for municipal buildings and other projects funded with money from the...

352

High Performance Commercial Building Systems William L. Carroll  

E-Print Network [OSTI]

Efficiency and Renewable Energy, Building Technologies Program of the U.S. Department of Energy underHigh Performance Commercial Building Systems William L. Carroll Ernest Orlando Lawrence Berkeley.2 ­ Retrofit Tools Task 2 HPBCS E2P2.2T3 LBNL - 57775 California Energy Commission Public Interest Energy

353

Modeling Building Thermal Response to HVAC Zoning Virginia Smith  

E-Print Network [OSTI]

Modeling Building Thermal Response to HVAC Zoning Virginia Smith Department of Computer Science HVAC systems account for 38% of building energy usage. Studies have indicated at least 5-15% waste due to unoccu- pied spaces being conditioned. Our goal is to minimize this waste by retrofitting HVAC systems

Whitehouse, Kamin

354

DOE Webinar - Residential Geothermal Heat Pump Retrofits (Presentation)  

SciTech Connect (OSTI)

This presentation was given December 14, 2010, as part of DOE's Webinar series. The presentation discusses geothermal heat pump retrofits, technology options, and an overview of geothermal energy and geothermal heat pumps.

Anderson, E. R.

2010-12-14T23:59:59.000Z

355

EECBG Success Story: Lighting Retrofits Saving Energy, Helping...  

Broader source: Energy.gov (indexed) [DOE]

Pa. thousands in energy costs. | File photo It's easy to measure the effects of a lighting retrofit project in a city like Altoona, Pennsylvania, where 169 new LED units are...

356

IRS Parking Facility Lighting Retrofit Reduces Annual Energy...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

in Kansas City, Missouri. The retrofit resulted in annual energy savings of 2 million kWh, annual cost savings of over 122,000, and a simple payback of 2.5 years....

357

Puget Sound Energy- Commercial Retrofit Energy Efficiency Grant Program  

Broader source: Energy.gov [DOE]

PSE can provide a custom retrofit grant for any energy-efficiency project that meets specified cost-effectiveness criteria and other PSE program requirements. To be eligible, customers must...

358

Street and Parking Facility Lighting Retrofit Financial Analysis Tool Webinar  

Broader source: Energy.gov [DOE]

DOE will present a live webinar titled "Using the Street and Parking Facility Lighting Retrofit Financial Analysis Tool" on Thursday, August 22, from 1:00 p.m. to 2:00 p.m. Eastern Daylight Time....

359

Tillamook County PUD- Dairy Lighting Retrofit Rebate Program  

Broader source: Energy.gov [DOE]

Tillamook PUD offers the Dairy Lighting Retrofit Program for its agricultural members to save energy on lighting in eligible barns/facilities. Tillamook PUD completes a lighting audit of the...

360

Demonstration Assessment of Light-Emitting Diode (LED) Retrofit Lamps at the Lobby of the Bonneville Power Administration, Portland, OR  

SciTech Connect (OSTI)

This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in the lobby of the Bonneville Power Administration (BPA) headquarters building in Portland, Oregon. The project involved a simple retrofit of 32 track lights used to illuminate historical black-and-white photos and printed color posters from the 1930s and 1940s. BPA is a federal power marketing agency in the Northwestern United States, and selected this prominent location to demonstrate energy efficient light-emitting diode (LED) retrofit options that not only can reduce the electric bill for their customers but also provide attractive alternatives to conventional products, in this case accent lighting for BPA's historical artwork.

Miller, Naomi

2011-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Better Buildings Neighborhood Program Peer Exchange Call on Financing and Revenue: Bond Funding Call Slides and Discussion Summary, March 28, 2013  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd: ScopeDepartment1, 2011 Better Buildings0,28, 2013 Better

362

Intercity Passenger Rail Federal Funding presented by  

E-Print Network [OSTI]

Intercity Passenger Rail ­ Federal Funding Process presented by: Minnesota Department, equipment and connections ·! Long term: build efficient HSR network ­! Connecting major population centers ·! Lead state on Milwaukee to Twin Cities segment ·! 2008 state bonding to match federal funds

Minnesota, University of

363

Retrofitting Doors on Open Refrigerated Cases | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartment of Energy fromComments onReplyofRetiring Procurement OfficialRetrofitRetrofitting

364

Case Study of Continuous Commissioning in an Office Building  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Building Commissioning for Energy Efficiency and Comfort, Vol.VI-9-3 Case Study of Continuous Commissioning? in an Office Building Xiufeng Pang Bin Zheng Mingsheng Liu Graduate Student Graduate...&M University examined system operations in a number of newly retrofitted buildings and found that optimizing the system can double energy savings and improve building comfort [Liu et al.]. In 1996, the CC? process was first developed. While most...

Pang, X.; Zheng, B.; Liu, M.

2006-01-01T23:59:59.000Z

365

Wynkoop Building Performance Measurement: Water  

SciTech Connect (OSTI)

This report is a summary of the water analysis performance for the Denver, Colorado Wynkoop Building. The Wynkoop Building (Figure 1) was built in 2006 as the Environmental Protection Agency (EPA) Region 8 Headquarters intended to house over 900 occupants in the 301,292 gross square feet (248,849 rentable square feet). The building was built on a brownfield in the Lower Downtown Historic District as part of an urban redevelopment effort. The building was designed and constructed through a public-private partnership with the sustainable design elements developed jointly by General Services Administration (GSA) and EPA. That partnership is still active with all parties still engaged to optimize building operations and use the building as a Learning Laboratory. The building design achieved U.S. Green Building Council Leadership in Energy and Environmental Design for New Construction (LEED-NC) Gold Certification in 2008 (Figure 2) and a 2008 EPA Energy Star Rating of 96 with design highlights that include: (1) Water use was designed to use 40% less than a typical design baseline. The design included low flow fixtures, waterless urinals and dual flush toilets; (2) Native and adaptive vegetation were selected to minimize the need for irrigation water for landscaping; and (3) Energy use intensity was modeled at 66.1 kBtus/gross square foot, which is 39% better than ASHRAE 90.1 1999. The Wynkoop Building water use (10 gallons/square foot) was measured at lower than industry average (15 gallons/square foot) and GSA goals (13 gallons/square foot), however, it was higher than building management expected it would be. The type of occupants and number of occupants can have a significant impact on fixture water use. The occupancy per floor varied significantly over the study time period, which added uncertainty to the data analysis. Investigation of the fixture use on the 2nd, 5th, and 7th floors identified potential for water use reduction if the flush direction of the dual-flush toilet handles was reversed. The building management retrofitted the building's toilets with handles that operated on reduced flush when pushed down (0.8 gallons) and full flush when pulled up (1.1 gallons). The water pressure on the 5th floor (< 30 psi) is less than half the pressure on the 7th floor (>80 psi). The measured water savings post-retrofit was lower on the 5th floor than the 7th floor. The differences in water pressure may have had an impact on the quantity of water used per floor. The second floor water use was examined prior to and following the toilet fixture retrofit. This floor is where conference rooms for non-building occupants are available for use, thus occupancy is highly variable. The 3-day average volume per flush event was higher post-retrofit (0.79 gallons per event), in contrast to pre-retrofit (0.57 gallons per event). There were 40% more flush events post retrofit, which impacted the findings. Water use in the third floor fitness center was also measured for a limited number of days. Because of water line accessibility, only water use on the men's side of the fitness center was measured and from that the total fitness center water use was estimated. Using the limited data collected, the fitness center shower water use is approximately 2% of the whole building water use. Overall water use in the Wynkoop Building is below the industry baseline and GSA expectations. The dual flush fixture replacement appears to have resulted in additional water savings that are expected to show a savings in the total annual water use.

Fowler, Kimberly M.; Kora, Angela R.

2012-08-26T23:59:59.000Z

366

Review of Existing Energy Retrofit Tools  

E-Print Network [OSTI]

Commercial End-Use Survey (CEUS) database and other sources. The data fields include the building's energy usage,

Lee, Sang Hoon

2014-01-01T23:59:59.000Z

367

Energy Efficiency and Conservation Block Grant Program  

Broader source: Energy.gov (indexed) [DOE]

funds as the matching share and application fee for the New Jersey Local Government Energy Audit Program; 2) conduct building retrofit activities in the Municipal Building (1970s)...

368

Balancing Hydronic Systems in Multifamily Buildings  

SciTech Connect (OSTI)

In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution and controls. The effects of imbalance include tenant discomfort, higher energy use intensity and inefficient building operation. This paper explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The research was conducted by The Partnership for Advanced Residential Retrofit (PARR) in conjunction with Elevate Energy. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61 degrees F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1 degrees F to 15.5 degrees F.

Ruch, R.; Ludwig, P.; Maurer, T.

2014-07-01T23:59:59.000Z

369

2014 Building America House Simulation Protocols  

SciTech Connect (OSTI)

As BA has grown to include a large and diverse cross-section of the home building and retrofit industries, it has become more important to develop accurate, consistent analysis techniques to measure progress towards the program's goals. The House Simulation Protocol (HSP) document provides guidance to program partners and managers so they can compare energy savings for new construction and retrofit projects. The HSP provides the program with analysis methods that are proven to be effective and reliable in investigating the energy use of advanced energy systems and of entire houses.

Wilson, E.; Engebrecht-Metzger, C.; Horowitz, S.; Hendron, R.

2014-03-01T23:59:59.000Z

370

Building America Expert Meeting Report: Hydronic Heating in Multifamily Buildings  

SciTech Connect (OSTI)

The topic of this expert meeting was cost-effective controls and distribution retrofit options for hot water and steam space heating systems in multi-family buildings with the goals of reducing energy waste and improving occupant comfort. The U.S. Department of Energy's Building America program develops technologies with the goal of reducing energy use by 30% to 50% in residential buildings. Toward this goal, the program sponsors 'Expert Meetings' focused on specific building technology topics. The meetings are intended to sharpen Building America research priorities, create a forum for sharing information among industry leaders and build partnerships with professionals and others that can help support the program's research needs and objectives. The topic of this expert meeting was cost-effective controls and distribution retrofit options for hot water and steam space heating systems in multifamily buildings with the goals of reducing energy waste and improving occupant comfort. The objectives of the meeting were to: (1) Share knowledge and experience on new and existing solutions: what works, what doesn't and why, and what's new; (2) Understand the market barriers to currently offered solutions: what disconnects exist in the market and what is needed to overcome or bridge these gaps; and (3) Identify research needs.

Dentz, J.

2011-10-01T23:59:59.000Z

371

Impact of Nighttime Shut Down on the Prediction Accuracy of Monthly Regression Models for Energy Consumption in Commercial Buildings  

E-Print Network [OSTI]

Regression models of measured energy use in buildings are widely used as baseline models to determine retrofit savings from measured energy consumption. It is less expensive to determine savings from monthly utility bills when they are available...

Wang, J.; Claridge, D. E.

1998-01-01T23:59:59.000Z

372

Conservation Trust Funds  

E-Print Network [OSTI]

than $50,000, such as Suriname's Forest People's Fund, "levels. 94 For example, the Suriname trust fund operates at

Guerin-McManus, Marianne

2001-01-01T23:59:59.000Z

373

Housing Archetype Analysis for Home Energy-Efficient Retrofit in the Great Lakes Region  

SciTech Connect (OSTI)

This project report details activities and results of the 'Market Characterization' project undertaken by the Cost Effective Energy Retrofit (CEER) team targeted toward the DOE goal of achieving 30%-50% reduction in existing building energy use. CEER consists of members from the Dow Chemical Company, Michigan State University, Ferris State University and Habitat for Humanity Kent County. The purpose of this market characterization project was to identify housing archetypes which are dominant within Great Lakes region and therefore offer significant potential for energy-efficient retrofit research and implementation due to the substantial number of homes possessing similar characteristics. Understanding the characteristics of housing groups referred to as 'archetypes' by vintage, style, and construction characteristics can allow research teams to focus their retrofit research and develop prescriptive solutions for those structure types which are prevalent and offer high potential uptake within a region or market. Key research activities included; literature review, statistical analysis of national and regional data of the American Housing Survey (AHS) collected by the U.S. Census Bureau, analysis of Michigan specific data, development of a housing taxonomy of architectural styles, case studies of two local markets (i.e., Ann Arbor and Grand Rapids in Michigan) and development of a suggested framework (or process) for characterizing local markets. In order to gain a high level perspective, national and regional data from the U.S. Census Bureau was analyzed using cross tabulations, multiple regression models, and logistic regression to characterize the housing stock and determine dominant house types using 21 variables.

Kim, S. K.; Mrozowski, T.; Harrell-Seyburn, A.; Ehrlich, N.; Hembroff, L.; Bieburn, B.; Mazor, M.; McIntyre, A.; Mutton, C.; Parsons, G.; Syal, M. G.; Wilkinson, R.

2014-09-01T23:59:59.000Z

374

Calibration of Building Energy Models: Supercomputing, Big-Data and Machine-Learning  

E-Print Network [OSTI]

Modeling (BEM) is an approach to model the energy usage in buildings for design and retrofit purposesCalibration of Building Energy Models: Supercomputing, Big-Data and Machine-Learning Jibonananda Sanyal, Joshua New, Richard Edwards Energy and Environmental Sciences Directorate Building Energy

Wang, Xiaorui "Ray"

375

Future Funding: Effective Models for Leveraging Public Funds...  

Broader source: Energy.gov (indexed) [DOE]

to Design and Market Energy Efficiency Programs to Specific Neighborhoods Developing an Evaluation Measurement, and Verification Plan: Residential Retrofits A Primer on EM&V,...

376

Auto-DR and Pre-cooling of Buildings at Tri-City Corporate Center  

E-Print Network [OSTI]

funded Demand Response Research Center, a building energyto maximize demand response savings for these buildings. Theapply the demand response strategies in the building on the

Yin, Rongxin

2010-01-01T23:59:59.000Z

377

Acceleration Fund  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth (AOD)ProductssondeadjustsondeadjustAbout the Building Technologies Office AboutAccelerateAccelerating

378

Review of Existing Energy Retrofit Tools  

E-Print Network [OSTI]

with Title 24 - Uses SketchUp for geometry creation -plug-in for Trimble SketchUp is used for the building

Lee, Sang Hoon

2014-01-01T23:59:59.000Z

379

Small Market Advanced Retrofit Transformation Program (SMART...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

and government administrators of energy efficiency programs for small- and medium-sized buildings (SMBs). SMART Scale is looking to achieve an average of 20% energy savings per...

380

Demonstrating and Deploying Integrated Retrofit Technologies...  

Broader source: Energy.gov (indexed) [DOE]

and solutions that can achieve 50% energy reduction in small- and medium-sized commercial buildings (SMSCBs). The Penn State Consortium collaborates with other research...

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Addendum to the Building America House Simulation Protocols  

SciTech Connect (OSTI)

As Building America (BA) has grown to include a large and diverse cross-section of the home building and retrofit industries, it has become more important to develop accurate, consistent analysis techniques to measure progress towards the program's goals. The House Simulation Protocols (HSP) provides guidance to program partners and managers so that energy savings for new construction and retrofit projects can be compared alongside each other. The HSP provides the program with analysis methods that are proven to be effective and reliable in investigating the energy use of advanced energy systems and of entire houses.

Engebrecht-Metzger, C.; Wilson, E.; Horowitz, S.

2012-12-01T23:59:59.000Z

382

Effects of Catalysts on Emissions from Heavy-Duty Diesel Retrofits...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Catalysts on Emissions from Heavy-Duty Diesel Retrofits for PM and NOX Control Effects of Catalysts on Emissions from Heavy-Duty Diesel Retrofits for PM and NOX Control The more...

383

Retrofit and Testing of a Pre-Turbo, Diesel Oxidation Catalyst...  

Broader source: Energy.gov (indexed) [DOE]

Retrofit and Testing of a Pre-Turbo, Diesel Oxidation Catalyst on a Tier 0, SD60M Freight Locomotive Achieving Over 50% PM Reduction Retrofit and Testing of a Pre-Turbo, Diesel...

384

ADEC II Universal SCR Retrofit System for On-road and Off-road...  

Broader source: Energy.gov (indexed) [DOE]

ADEC II Universal SCR Retrofit System for On-road and Off-road Diesel Engines ADEC II Universal SCR Retrofit System for On-road and Off-road Diesel Engines Presentation given at...

385

Notice of Intent: Buildings University Innovators and Leaders...  

Broader source: Energy.gov (indexed) [DOE]

behalf of the Building Technologies Office, a Notice of Intent DE-FOA-0001191 concerning Funding Opportunity Announcement (FOA) DE-FOA-0001167 "Buildings University Innovators and...

386

Housing Stock Characterization Study: An Innovative Approach to Measuring Retrofit Impact  

SciTech Connect (OSTI)

A residential energy efficiency retrofit loan program depends on a self-sustaining finance option and optimized retrofit measures that recoup their unsubsidized costs through energy bill savings alone within the useful life of the retrofit. A first step in evaluating retrofit options is to measure and verify their energy savings. This report evaluates Orlando Utilities Commission (OUC) residential energy-efficiency demand side management (DSM) programs to assess their relative energy and economic performance.

Jones, P.; Taylor, N.; Kipp, J.

2012-09-01T23:59:59.000Z

387

Sustainable Energy Resources for Consumers Webinar on Residential Geothermal Heat Pump Retrofit Transcript  

Broader source: Energy.gov [DOE]

Transcript for a U.S. Department of Energy Webinar on Dec. 14, 2010, about residential geothermal heat pump retrofits

388

Building America Case Study: Balancing Hydronic Systems in Multifamily Buildings, Chicago, Illinois (Fact Sheet)  

SciTech Connect (OSTI)

In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution and controls. The effects of imbalance include tenant discomfort, higher energy use intensity and inefficient building operation. This paper explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The research was conducted by The Partnership for Advanced Residential Retrofit (PARR) in conjunction with Elevate Energy. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61 degrees F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1 degrees F to 15.5 degrees F.

Not Available

2014-09-01T23:59:59.000Z

389

Joseph Vance Building, The  

High Performance Buildings Database

Seattle, WA In 2006, the Rose Smart Growth Investment Fund acquired the historic Joseph Vance Building with the purpose of transforming it into "the leading green and historic class B" building in the marketplace. The terra cotta Vance Building was constructed in 1929 and has 14 floors - 13 floors of offices over ground-floor retail with a basement for mechanical equipment and storage. In 2009 the U.S. Green Building Council (USGBC) awarded the Vance Building LEED for Existing Buildings (EB) Gold certification.

390

Measure Guideline: Three High Performance Mineral Fiber Insulation Board Retrofit Solutions  

SciTech Connect (OSTI)

This Measure Guideline describes a high performance enclosure retrofit package that uses mineral fiber insulation board. The Measure Guideline describes retrofit assembly and details for wood frame roof and walls and for cast concrete foundations. This Measure Guideline is intended to serve contractors and designers seeking guidance for non-foam exterior insulation retrofit.

Neuhauser, K.

2015-01-01T23:59:59.000Z

391

Modular industrial solar retrofit project (MISR)  

SciTech Connect (OSTI)

The intent of this paper is to describe a major Department of Energy (DOE) thrust to bring line-focus solar thermal technology to commercial readiness. This effort is referred to as the MISR Project. The project is based upon the premise that thermal energy is the basic solar thermal system output and that low-temperature, fossil fuel applications are technically the first that should be retrofitted. Experience has shown that modularity in system design and construction offers potential for reducing engineering design costs, reduces manufacturing costs, reduces installation time and expense, and improves system operational reliability. The modular design effort will be sponsored by Sandia National Laboratories with industry doing the final designs. The operational credibility of the systems will be established by allowing selected industrial thermal energy users to purchase MISR systems from suppliers and operate them for two years. Industries will be solicited by DOE/Albuquerque Operations Office to conduct these experiments on a cost sharing basis. The MISR system allowed in the experiments will have been previously qualified for the application. The project is divided into three development phases which represent three design and experiment cycles. The first cycle will use commercially available trough-type solar collectors and will incorporate 5 to 10 experiments of up to 5000 m/sup 2/ of collectors each. The project effort began in March 1980, and the first cycle is to be completed in 1985. Subsequent cycles will begin at 3-year intervals. The project is success oriented, and if the first cycle reaches commercial readiness, the project will be terminated. If not, a second, and possibly a third, development cycle will be conducted.

Alvis, R.L.

1980-01-01T23:59:59.000Z

392

Pilot Demonstration of Phased Retrofits in Florida Homes (Fact Sheet)  

SciTech Connect (OSTI)

The Florida Solar Energy Center (FSEC) and Florida Power and Light are pursuing a collaborative energy research/utility partnership to retrofit a large number of homes using a phased approach. The project is creating detailed data on the energy and economic performance of two levels of home retrofit - simple and deep. Acting as a pilot, this project is expected to provide the information necessary to significantly reduce energy use through much larger community-scale projects in collaboration with utilities, program administrators and other market leader stakeholders.

Not Available

2014-08-01T23:59:59.000Z

393

Flexible Capital Fund (Vermont)  

Broader source: Energy.gov [DOE]

The Vermont Sustainable Jobs Fund's Flexible Capital Fund (the “Flex Fund”) is designed for companies in Vermont's rural areas that are smaller and work on a less-than global scale, offering a...

394

Measured Cooling Performance and Potential for Buried Duct Condensation in a 1991 Central Florida Retrofit Home  

SciTech Connect (OSTI)

FSEC conducted energy performance monitoring of two existing residences in Central Florida that were undergoing various retrofits. These homes were occupied by FSEC researchers and were fully instrumented to provide detailed energy, temperature, and humidity measurements. The data provided feedback about the performance of two levels of retrofit in two types of homes in a hot-humid climate. This report covers a moderate-level retrofit and includes two years of pre-retrofit data to characterize the impact of improvements. The other home is a 'deep energy retrofit' (detailed in a separate report) that has performed at near zero energy with a photovoltaic (PV) system and extensive envelope improvements.

Chasar, D.; Withers, C.

2013-02-01T23:59:59.000Z

395

Hygric Redistribution in Insulated Assemblies: Retrofitting Residential Envelopes Without Creating Moisture Issues  

SciTech Connect (OSTI)

The Building America program has recognized that most of the current housing stock is in need of energy related retrofits. One of the best ways of reducing the space conditioning energy consumption is to improve the thermal performance of the enclosure by adding exterior board foam insulation. This report quantifies the amount of water that can become trapped in the drainage cavity of typical wall systems, and measures the effect of water trapped in the drainage cavity on the moisture content of the sheathing. This study also attempts to explain the discrepancy between hygrothermal simulations and field performance of low permeance, low R-value exterior insulation (e.g. 3/4-in. foil faced polyisocyanurate) in cold climates.

Smegal, J.; Lstiburek, J.

2013-01-01T23:59:59.000Z

396

Exploring Cost-Effective, High Performance Residential Retrofits for Affordable Housing in the Hot Humid Climate  

SciTech Connect (OSTI)

In 2009, a Department of Energy Building America team led by the Florida Solar Energy Center began working with partners to find cost-effective paths for improving the energy performance of existing homes in the hot humid climate. A test-in energy audit and energy use modeling of the partner's proposed renovation package was performed for 41 affordable and middle income foreclosed homes in Florida and Alabama. HERS1 Indices ranged from 92 to 184 with modeled energy savings ranging from 3% to 50% (average of 26%). Analyses and recommendations were discussed with partners to encourage more efficient retrofits, highlight health and safety issues, and gather feedback on incremental cost of high performance measures. Ten completed renovations have modeled energy savings ranging from 9% to 48% (average 31%.) This paper presents the project's process including our findings thus far and highlights of the first home to meet the target HERS Index of 70.

McIlvaine, Janet; Sutherland, Karen; Schleith, Kevin; Chandra, Subrato

2010-08-27T23:59:59.000Z

397

SPRAY FOAM IN ACCESSIBLE SPACES:BEST PRACTICES AND CASE STUDIES FOR RETROFIT IN MIXED-HUMID CLIMATE  

SciTech Connect (OSTI)

Heating and cooling the house is one of the homeowners major expenses. Reducing these costs, saving energy, and creating a healthier, more comfortable indoor environment are good reasons to consider improving the building thermal envelope. Improvements usually consider increasing the amount of insulation, reducing the infiltration of outside air, and controlling moisture in existing buildings. This report describes the use of spray foam materials to insulate, seal, and control moisture. This discussion is limited to treating areas that are accessible. What is accessible, however, can vary depending on the type of renovation. If the building has been gutted or exterior surfaces removed, there are more options. This report will look at areas to consider for spray foam application and discuss the types of spray foams available and their uses. A number of case studies are presented to show the effectiveness of this retrofit in existing houses based on performance data.

Christian, Jeffrey E [ORNL; Gant, Kathy [Oak Ridge National Laboratory (ORNL)

2013-12-01T23:59:59.000Z

398

2008 ACEEE Summer Study on Energy Efficiency in Buildings August 1722, 2008 Asilomar Conference Center Pacific Grove, California  

E-Print Network [OSTI]

2008 ACEEE Summer Study on Energy Efficiency in Buildings August 17­22, 2008 · Asilomar Conference Center · Pacific Grove, California 1 Targeting Energy Efficiency in Commercial Buildings Using Advanced energy use, prioritizes buildings for specific energy-efficiency retrofits, and tracks weather

Kissock, Kelly

399

Florida Growth Fund (Florida)  

Broader source: Energy.gov [DOE]

The Florida Growth Fund can provide investments in technology and growth-related companies through co-investments with other institutional investors. The Fund awards preference to companies...

400

Better Buildings Neighborhood Program: BetterBuildings Lowell Final Report  

SciTech Connect (OSTI)

The City of Lowell set four goals at the beginning of the Better Buildings Neighborhood Program: 1. Improve the Downtown Historic Park District’s Carbon Footprint 2. Develop a sustainable and replicable model for energy efficiency in historic buildings 3. Create and retain jobs 4. Promote multi?stakeholder partnerships The City of Lowell, MA was awarded $5 million in May 2010 to conduct energy efficiency retrofits within the downtown National Historical Park (NHP). The City’s target was to complete retrofits in 200,000 square feet of commercial space and create 280 jobs, while adhering to the strict historical preservation regulations that govern the NHP. The development of a model for energy efficiency in historic buildings was successfully accomplished. BetterBuildings Lowell’s success in energy efficiency in historic buildings was due to the simplicity of the program. We relied strongly on the replacement of antiquated HVAC systems and air sealing and a handful of talented energy auditors and contractors. BetterBuildings Lowell was unique for the Better Buildings Neighborhood Program because it was the only program that focused solely on commercial properties. BetterBuildings Lowell did target multi?family properties, which were reported as commercial, but the majority of the building types and uses were commercial. Property types targeted were restaurants, office buildings, museums, sections of larger buildings, mixed use buildings, and multifamily buildings. This unique fabric of building type and use allows for a deeper understanding to how different properties use energy. Because of the National Historical Park designation of downtown Lowell, being able to implement energy efficiency projects within a highly regulated historical district also provided valuable research and precedent proving energy efficiency projects can be successfully completed in historical districts and historical buildings. Our program was very successful in working with the local Historic Board, which has jurisdiction in the NHP. The Historic Board was cooperative with any exterior renovations as long as they were not changing the existing aesthetics of the property. If we were replacing a rooftop condenser it needed to be placed where the existing rooftop condenser was located. Receiving proper approval from the Historic Board for any external energy conservation measures was known by all the participating contractors. One area of the retrofits that was contentious regarded venting of the new HVAC equipment. Installing external stacks was not allowed so the contractors had to negotiate with the Historic Board regarding the proper way to vent the equipment that met the needs mechanically and aesthetically. Overall BetterBuildings Lowell was successful at implementing energy and cost saving measures into 31 commercial properties located within the NHP. The 31 retrofits had 1,554,768 square feet of commercial and multifamily housing and a total predicted energy savings exceeding 22,869 a year. Overall the City of Lowell achieved its target goals and is satisfied with the accomplishments of the BetterBuildings program. The City will continue to pursue energy efficient programs and projects.

Heslin, Thomas

2014-01-31T23:59:59.000Z

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Seismic Retrofitting of RC Frames with RC Infilling  

E-Print Network [OSTI]

Seismic Retrofitting of RC Frames with RC Infilling SERIES Workshop: "Role of research infrastructures in seismic rehabilitation" 8 - 9 February 2012, Istanbul, Turkey C. Z. Chrysostomou, N. Kyriakides, P. Kotronis, P. Roussis, M. Poljansek, F. Taucer RC Infilling of Existing RC Structures for Seismic

402

Apply: Funding Opportunity - Building America Industry Partnerships...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

in 2012. Space heating and cooling account for the largest portion of home energy consumption, more than water heating, refrigeration, and lighting combined. Between 2007...

403

BUILDING ECONOMIC DEVELOPMENT FUNDING IN ACTION  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth (AOD)ProductssondeadjustsondeadjustAboutScience Program CumulusAMarch-6,-2015BSCmemo.pdf BSCmemo.pdfR I S

404

External Research Funding Agreements  

E-Print Network [OSTI]

1 External Research Funding Agreements University Policy No: RH8200 Classification: Research and university employees under Research Funding Agreements. DEFINITIONS 2.00 Research Funding Agreement means funding provided through an agreement with the university to be used for research purposes, whether

Victoria, University of

405

STEEL PLATE SHEAR WALL BUILDINGS: DESIGN REQUIREMENTS AND RESEARCH  

E-Print Network [OSTI]

STEEL PLATE SHEAR WALL BUILDINGS: DESIGN REQUIREMENTS AND RESEARCH Michel Bruneau, P.E. 1 Dr. Bruneau is conducting research on the seismic evaluation and retrofit of existing steel bridges, steel of this research, and has co- authored the book "Ductile Design of Steel Structures" published in 1997 by Mc

Bruneau, Michel

406

DOE to Fund up to $454 Million for Retrofit Ramp-Ups in Energy Efficiency |  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomentheATLANTA, GA - U.S. Department ofThe U.S.D.C.Energy TheDepartment of

407

Economic Energy Savings Potential in Federal Buildings  

SciTech Connect (OSTI)

The primary objective of this study was to estimate the current life-cycle cost-effective (i.e., economic) energy savings potential in Federal buildings and the corresponding capital investment required to achieve these savings, with Federal financing. Estimates were developed for major categories of energy efficiency measures such as building envelope, heating system, cooling system, and lighting. The analysis was based on conditions (building stock and characteristics, retrofit technologies, interest rates, energy prices, etc.) existing in the late 1990s. The potential impact of changes to any of these factors in the future was not considered.

Brown, Daryl R.; Dirks, James A.; Hunt, Diane M.

2000-09-04T23:59:59.000Z

408

The System Approach to Thermal Performance - Control of Condensation and Mold in Buildings  

E-Print Network [OSTI]

sealing which controls the leakage of air and moisture vapor into the building envelope. New soft foam insulation is now being used in retrofit and new buildings to solve mold and moisture condensation problems. At the same time downsizing of HVAC...

Nicklas, R.

2002-01-01T23:59:59.000Z

409

Autonomous Correction of Sensor Data Applied to Building Technologies Using Filtering Methods  

E-Print Network [OSTI]

and commercial buildings consume 41% of primary energy (72% electricity) used in the U.S. · Retrofitting inefficient buildings with new and innovative technologies that help to curb energy consumption will reduce filters. · Specifically, temperature, humidity, energy usage, pressure, and airflow sensor data is used

Wang, Xiaorui "Ray"

410

Analysis of the Chinese Market for Building Energy Efficiency  

SciTech Connect (OSTI)

China will account for about half of the new construction globally in the coming decade. Its floorspace doubled from 1996 to 2011, and Chinese rural buildings alone have as much floorspace as all of U.S. residential buildings. Building energy consumption has also grown, increasing by over 40% since 1990. To curb building energy demand, the Chinese government has launched a series of policies and programs. Combined, this growth in buildings and renovations, along with the policies to promote green buildings, are creating a large market for energy efficiency products and services. This report assesses the impact of China’s policies on building energy efficiency and on the market for energy efficiency in the future. The first chapter of this report introduces the trends in China, drawing on both historical analysis, and detailed modeling of the drivers behind changes in floorspace and building energy demand such as economic and population growth, urbanization, policy. The analysis describes the trends by region, building type and energy service. The second chapter discusses China’s policies to promote green buildings. China began developing building energy codes in the 1980s. Over time, the central government has increased the stringency of the code requirements and the extent of enforcement. The codes are mandatory in all new buildings and major renovations in China’s cities, and they have been a driving force behind the expansion of China’s markets for insulation, efficient windows, and other green building materials. China also has several other important policies to encourage efficient buildings, including the Three-Star Rating System (somewhat akin to LEED), financial incentives tied to efficiency, appliance standards, a phasing out of incandescent bulbs and promotion of efficient lighting, and several policies to encourage retrofits in existing buildings. In the third chapter, we take “deep dives” into the trends affecting key building components. This chapter examines insulation in walls and roofs; efficient windows and doors; heating, air conditioning and controls; and lighting. These markets have seen significant growth because of the strength of the construction sector but also the specific policies that require and promote efficient building components. At the same time, as requirements have become more stringent, there has been fierce competition, and quality has at time suffered, which in turn has created additional challenges. Next we examine existing buildings in chapter four. China has many Soviet-style, inefficient buildings built before stringent requirements for efficiency were more widely enforced. As a result, there are several specific market opportunities related to retrofits. These fall into two or three categories. First, China now has a code for retrofitting residential buildings in the north. Local governments have targets of the number of buildings they must retrofit each year, and they help finance the changes. The requirements focus on insulation, windows, and heat distribution. Second, the Chinese government recently decided to increase the scale of its retrofits of government and state-owned buildings. It hopes to achieve large scale changes through energy service contracts, which creates an opportunity for energy service companies. Third, there is also a small but growing trend to apply energy service contracts to large commercial and residential buildings. This report assesses the impacts of China’s policies on building energy efficiency. By examining the existing literature and interviewing stakeholders from the public, academic, and private sectors, the report seeks to offer an in-depth insights of the opportunities and barriers for major market segments related to building energy efficiency. The report also discusses trends in building energy use, policies promoting building energy efficiency, and energy performance contracting for public building retrofits.

Yu, Sha; Evans, Meredydd; Shi, Qing

2014-03-20T23:59:59.000Z

411

Building Technologies Program - 1995 Annual Report  

E-Print Network [OSTI]

Design Tool for Small Commercial Buildings A DOE-funded industry/laboratory collaboration between the Passive Solardesign guidance for the optimal utiliza- tion of passive solar technologies in small commercial buildings.

Selkowitz, S.E.

2010-01-01T23:59:59.000Z

412

Simulation- Assisted Audit of an Air Conditioned Office Building  

E-Print Network [OSTI]

Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 performances of the installation. Finally, some significant retrofit opportunities are proposed. BUILDING DESCRIPTION Building design The considered building is an existing... Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 In nominal heating conditions (outdoor : -10?C/RH 90%; indoor : 20?C/RH50%), with ?t = 30 K, this gives a sensible power demand of: g1843g4662g3046,g3041g3042g3040 =g343623...

Bertagnolio, S.; Lebrun, J.; Hannay, J.; Silva, C. A.

413

Conceptual design of a coal-fired MHD retrofit plant. Topical report, Seed Regeneration System Study 2  

SciTech Connect (OSTI)

Westinghouse Advanced Energy Systems (WAES), through Contract No. DE-AC22-87PC79668 funded by US DOE/PETC, is conducting a conceptual design study to evaluate a coal-fired magnetohydrodynamic (MHD) retrofit of a utility plant of sufficient size to demonstrate the technical and future economic viability of an MHD system operating within an electric utility environment. The objective of this topical report is to document continuing seed regeneration system application studies and the definition of will system integration requirements for the Scholz MHD retrofit plant design. MHD power plants require the addition of a seeding material in the form of potassium to enhance the ionization of the high temperature combustion gas in the MHD channel. This process has an added environmental advantage compared to other types of coal-fired power plants in that the potassium combines with the naturally occurring sulfur in the coal to form a potassium sulfate flyash (K{sub 2}SO{sub 4}) which can be removed from the process by appropriate particulate control equipment. Up to 100% of the Sulfur in the coal can be removed by this process thereby providing environmentally clean power plant operation that is better than required by present and anticipated future New Source Performance Standards (NSPS).

Not Available

1992-11-01T23:59:59.000Z

414

Decision analysis for seismic retrofit of structures  

E-Print Network [OSTI]

of earthquakes as deterministic statements that will not occur for a long time rather than as probabilistic statements about the events (May 2004). Due to the aforementioned concerns regarding the decreased likelihood of building damage from seismic activity...-05, American Society of Civil Engineers, Reston, VA. Bai, J.-W., Hueste, M. B., and Gardoni, P. (2007). ?A probabilistic framework for the assessment of structural losses due to seismic events.? J. Struct. Engrg., submitted for review. Bracci, J. M...

Williams, Ryan J.

2009-05-15T23:59:59.000Z

415

An Assessment of Envelope Measures in Mild Climate Deep Energy Retrofits  

SciTech Connect (OSTI)

Energy end-uses and interior comfort conditions have been monitored in 11 Deep Energy Retrofits (DERs) in a mild marine climate. Two broad categories of DER envelope were identified: first, bringing homes up to current code levels of insulation and airtightness, and second, enhanced retrofits that go beyond these code requirements. The efficacy of envelope measures in DERs was difficult to determine, due to the intermingled effects of enclosure improvements, HVAC system upgrades and changes in interior comfort conditions. While energy reductions in these project homes could not be assigned to specific improvements, the combined effects of changes in enclosure, HVAC system and comfort led to average heating energy reductions of 76percent (12,937 kWh) in the five DERs with pre-retrofit data, or 80percent (5.9 kWh/ft2) when normalized by floor area. Overall, net-site energy reductions averaged 58percent (15,966 kWh; n=5), and DERs with code-style envelopes achieved average net-site energy reductions of 65percent (18,923 kWh; n=4). In some homes, the heating energy reductions were actually larger than the whole house reductions that were achieved, which suggests that substantial additional energy uses were added to the home during the retrofit that offset some heating savings. Heating system operation and energy use was shown to vary inconsistently with outdoor conditions, suggesting that most DERs were not thermostatically controlled and that occupants were engaged in managing the indoor environmental conditions. Indoor temperatures maintained in these DERs were highly variable, and no project home consistently provided conditions within the ASHRAE Standard 55-2010 heating season comfort zone. Thermal comfort and heating system operation had a large impact on performance and were found to depend upon the occupant activities, so DERs should be designed with the occupants needs and patterns of consumption in mind. Beyond-code building envelopes were not found to be strictly necessary for the achievement of deep energy savings in existing uninsulated homes in mild marine climates, provided that other energy end-uses were comprehensively reduced. We recommend that mild climate DERs pursue envelopes in compliance with the 2012 International Energy Conservation Code (IECC) and pair these with high efficiency, off-the-shelf HVAC equipment. Enhanced building envelopes should be considered in cases where very low heating energy use (<1,000 kWh/year or <0.5 kWh/ft2-year) and enhanced thermal comfort (ASHRAE 55-2010) are required, as well as in those situations where substantial energy uses are added to the home, such as decorative lighting, cooling or smart home A/V and communication equipment.

Walker, Iain; Less, Brennan

2014-06-01T23:59:59.000Z

416

--No Title--  

Broader source: Energy.gov (indexed) [DOE]

funds include lighting and controls, EMS upgrades, building envelop improvements, and pipe insulation. EECBG-EERERW Energy Efficiency and Renewable Energy Retrofits for Knox...

417

University Buildings Landmark Buildings  

E-Print Network [OSTI]

KEY University Buildings Landmark Buildings The Lanyon Building Roads Footpath Cafe Grass Queen's University Belfast Campus Map The Lanyon Building The Students' Union The David Keir Building School Offices and Sonic Arts Q Nursing and Midwifery R Pharmacy S Planning, Architecture and Civil Engineering T Politics

Paxton, Anthony T.

418

University Buildings Landmark Buildings  

E-Print Network [OSTI]

KEY University Buildings Landmark Buildings The Lanyon Building Roads Footpath Cafe University Accommodation Queen's University Belfast Campus Map The Lanyon Building The Students' Union The David Keir Building School Offices A Biological Sciences B Chemistry and Chemical Engineering C Education D

Müller, Jens-Dominik

419

University Buildings Landmark Buildings  

E-Print Network [OSTI]

KEY University Buildings Landmark Buildings The Lanyon Building Roads Footpath Cafe University Engineering N Medicine, Dentistry and Biomedical Sciences P Music and Sonic Arts Q Nursing and Midwifery R and Student Affairs 3 Administration Building 32 Ashby Building 27 Belfast City Hospital 28 Bernard Crossland

Paxton, Anthony T.

420

Buildings Events | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

December 2014 < prev next > Sun Mon Tue Wed Thu Fri Sat 30 1 2 3 4 5 6 BENEFIT Funding Opportunity - Webinar 2 3:00PM to 4:00PM EST Buildings of the Future Research Project Launch...

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Building Energy Audit Report for Pearl Harbor, HI  

SciTech Connect (OSTI)

A building energy audit was performed by a team of engineers from Pacific Northwest National Laboratory (PNNL) under contract to the Department of Energy/Federal Energy Management Program (FEMP). The effort used the Facility Energy Decision System (FEDS) model to determine how energy is consumed at selected Pearl Harbor buildings, identify cost-effective energy retrofit measures, and calculate the potential energy and cost savings. This report documents the findings of that assessment.

Brown, Daryl R.; Chvala, William D.; De La Rosa, Marcus I.; Dixon, Douglas R.

2010-09-30T23:59:59.000Z

422

Next Step Toward Widespread Residential Deep Energy Retrofits  

SciTech Connect (OSTI)

The complexity of deep energy retrofits warrants additional training to successfully manage multiple improvements that will change whole house air, heat, and moisture flow dynamics. The home performance contracting industry has responded to these challenges by aggregating skilled labor for assessment of and implementation under one umbrella. Two emerging business models are profiled that seek to resolve many of the challenges, weaknesses, opportunities, and threats described for the conventional business models.

McIlvaine, J.; Saunders, S.; Bordelon, E.; Baden, S.; Elam, L.; Martin, E.

2013-07-01T23:59:59.000Z

423

Commissioning of the Fresno, California, Retrofit Unoccupied Test House  

SciTech Connect (OSTI)

Commissioning of instrumentation and limited short-term testing have been completed on a retrofit unoccupied test house in Fresno, California. This house is intended to be used as a laboratory in which several different methods of space conditioning distribution will be evaluated. This report provides background on the project, including specifications of the house and models used in its development, along with models to be evaluated through its operation.

Stecher, D.; Imm, C.

2013-06-01T23:59:59.000Z

424

Continuous Commissioning: A Valuable Partner to Retrofit Projects  

E-Print Network [OSTI]

-hand corner. Prior to commissioning, any changes in the duct static pressure or discharge air temperature setpoints did not affect the VFD speed. The operation of five AHUs was analyzed using the data collected through the EMCS. Table 2 presents summarized... variable frequency drives on constant speed motors and installing/modifying the DDC control system to control and optimize operation and to improve the system efficiency. In most cases, the retrofit projects realize their projected energy savings...

Turner, W. D.; Banks, K.; Athar, A.; Yazdani, B.; Zhu, Y.; Culp, C.

2001-01-01T23:59:59.000Z

425

Energy Efficient Crawlspace Foundation Retrofit: Mixed Humid Climate  

SciTech Connect (OSTI)

Residential quality management systems have most often been designed for new home construction. To address quality in existing homes in the form of Scopes of Work (SOW), the NAHB Research Center began with a new construction scope of work and applied it to an existing home project. This document is intended to outline the steps of translating a new home construction SOW to SOW for retrofit.

Del Bianco, M.; Wiehagen, J.; Wood, A.

2013-01-01T23:59:59.000Z

426

Retrofit Program Lead-by-Example Resources | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartment of Energy fromComments onReplyofRetiring Procurement OfficialRetrofit Program

427

POSTGRADUATE Upper Level, Otto Beit Building  

E-Print Network [OSTI]

FUNDING YOUR POSTGRADUATE STUDIES AT UCT Upper Level, Otto Beit Building University Avenue North, the Postgraduate Funding Office and Postgraduate Centre were established at the University of Cape Town to provide apply for funding from both the University and from as many other sources of support as possible

Jarrett, Thomas H.

428

Enterprise Fund (Kentucky)  

Broader source: Energy.gov [DOE]

The Kentucky Enterprise Fund (KEF) is a state-sponsored, venture capital-like fund that invests in Kentucky-based seed and early stage technology companies. KEF supports the development of...

429

Calculating Energy and Demand Retrofit Savings for Stroman High School: Interim Report  

E-Print Network [OSTI]

As part of the LoanSTAR program, Stroman High School in Victoria Texas underwent two retrofits: a) an absorption chiller was changed to an electric vapor compression chiller, and b) an EMCS system was installed after about 5 months in the post retrofit... the pre-retrofit climate conditions. Both approaches are applied to the LoanSTAR site Stroman High School (SHS) in Victoria, Texas, in which (1) pre-retrofit data were not available , and (2) an absorption chiller was replaced by a vapor compression...

Liu, Y.; Reddy, T. A.; Katipamula, S.; Claridge, D. E.

1992-01-01T23:59:59.000Z

430

Text-Alternative Version: Using the Street and Parking Facility Lighting Retrofit Financial Analysis Tool  

Broader source: Energy.gov [DOE]

Below is the text-alternative version of the "Using the Street and Parking Facility Lighting Retrofit Financial Analysis Tool" webcast, held August 22, 2013.

431

Case study field evaluation of a systems approach to retrofitting a residential HVAC system  

E-Print Network [OSTI]

Practices for Residential HVAC Systems”. Boston, MA. Jump,techniques for measuring HVAC grille air flows". ASHRAEPractices Guide for Residential HVAC Retrofits. LBNL 53592.

Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

2003-01-01T23:59:59.000Z

432

Text-Alternative Version: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool Webcast  

Broader source: Energy.gov [DOE]

Below is the text-alternative version of the "Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool" webcast, held April 3, 2012.

433

ADEC II Universal SCR Retrofit System for On-road and Off-road...  

Broader source: Energy.gov (indexed) [DOE]

ADEC II Universal SCR Retrofit System for On-road and Off-road Diesel Engines Richard Carlson Extengine Transport Systems, LLC Fullerton, California 2006 DEER Conference Poster...

434

Deep Energy Retrofit Performance Metric Comparison: Eight California Case Studies  

SciTech Connect (OSTI)

In this paper we will present the results of monitored annual energy use data from eight residential Deep Energy Retrofit (DER) case studies using a variety of performance metrics. For each home, the details of the retrofits were analyzed, diagnostic tests to characterize the home were performed and the homes were monitored for total and individual end-use energy consumption for approximately one year. Annual performance in site and source energy, as well as carbon dioxide equivalent (CO{sub 2}e) emissions were determined on a per house, per person and per square foot basis to examine the sensitivity to these different metrics. All eight DERs showed consistent success in achieving substantial site energy and CO{sub 2}e reductions, but some projects achieved very little, if any source energy reduction. This problem emerged in those homes that switched from natural gas to electricity for heating and hot water, resulting in energy consumption dominated by electricity use. This demonstrates the crucial importance of selecting an appropriate metric to be used in guiding retrofit decisions. Also, due to the dynamic nature of DERs, with changes in occupancy, size, layout, and comfort, several performance metrics might be necessary to understand a project’s success.

Walker, Iain; Fisher, Jeremy; Less, Brennan

2014-06-01T23:59:59.000Z

435

Field Assessment of Energy Audit Tools for Retrofit Programs  

SciTech Connect (OSTI)

This project focused on the use of home energy ratings as a tool to promote energy retrofits in existing homes. A home energy rating provides a quantitative appraisal of a home's asset performance, usually compared to a benchmark such as the average energy use of similar homes in the same region. Home rating systems can help motivate homeowners in several ways. Ratings can clearly communicate a home's achievable energy efficiency potential, provide a quantitative assessment of energy savings after retrofits are completed, and show homeowners how they rate compared to their neighbors, thus creating an incentive to conform to a social standard. An important consideration is how rating tools for the retrofit market will integrate with existing home energy service programs. For residential programs that target energy savings only, home visits should be focused on key efficiency measures for that home. In order to gain wide adoption, a rating tool must be easily integrated into the field process, demonstrate consistency and reasonable accuracy to earn the trust of home energy technicians, and have a low monetary cost and time hurdle for homeowners. Along with the Home Energy Score, this project also evaluated the energy modeling performance of SIMPLE and REM/Rate.

Edwards, J.; Bohac, D.; Nelson, C.; Smith, I.

2013-07-01T23:59:59.000Z

436

BENEFIT 2015 Funding Opportunity Announcement Webinar 2 (Text Version)  

Broader source: Energy.gov [DOE]

Below is the text version of the webinar, BENEFIT 2015 Funding Opportunity Announcement 2, presented in October 2014 by Antonio Bouza and Jim Payne of the Building Technologies Office.

437

Renewing University Base Funding  

E-Print Network [OSTI]

Renewing University Base Funding The Priority Issues 29 February 2012 e conor funding to universities as an immediate goal. It has already put in place increases worth 3.5%. 2 undergraduate or postgraduate, be funded at the same rate. #12;3 Charles Darwin University Flinders University

438

Scholarship Fund (National Forestry  

E-Print Network [OSTI]

Forestry Scholarship Fund (National Forestry Master's Program (NFMP) The Forestry Scholarship Fund! 2014 Scholarship Offers A degree in forestry is a way of life. Trees, people, habitats, management that you will experience when you chose forestry as a career. #12;TRUSTEE FOR FORESTRY SCHOLARSHIP FUND ABN

Botea, Adi

439

An Experimental and Analytical Evaluation of Wall And Window Retrofit Configurations: Supporting the Residential Retrofit Best Practices Guide  

SciTech Connect (OSTI)

A Retrofit Best Practices Guide was developed to encourage homeowners to consider energy conservation issues whenever they modify their siding or windows. In support of this guide, an experimental program was implemented to measure the performance of a number of possible wall siding and window retrofit configurations. Both thermal and air-leakage measurements were made for a 2.4 x 2.4 m (8 x 8 ft) wall section with and without a 0.9 x 1.2 m (3 x 4 ft) window. The windows tested were previously well-characterized at a dedicated window test facility. A computer model was also used to provide information for the Best Practices Guide. The experimental data for walls and windows were used in conjunction with this model to estimate the total annual energy savings for several typical houses in a number of different locations.

Stovall, Therese K [ORNL; Petrie, Thomas [ORNL; Kosny, Jan [ORNL; Childs, Phillip W [ORNL; Atchley, Jerald Allen [ORNL; Hulvey, Kimberly D [ORNL

2007-11-01T23:59:59.000Z

440

City of Indianapolis Better Buildings Program  

SciTech Connect (OSTI)

In June 2010, the City of Indianapolis’ Office of Sustainability was awarded $10 million in grant funds through the U.S. Department of Energy’s Better Buildings Neighborhood Program (CFDA 81.128) funded by the 2009 American Recovery and Reinvestment Act. The purpose of the grant funds was to achieve energy savings in residential and commercial buildings through energy efficiency upgrades such as air sealing and insulation.

Trovillion, Kristen

2014-11-04T23:59:59.000Z

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Conceptual design of a coal-fired MHD retrofit. Final technical report  

SciTech Connect (OSTI)

Coal-fired magnetohydrodynamics (MHD) technology is ready for its next level of development - an integrated demonstration at a commercial scale. The development and testing of MHD has shown its potential to be the most efficient, least costly, and cleanest way to burn coal. Test results have verified a greater than 99% removal of sulphur with a potential for greater than 60% efficiency. This development and testing, primarily funded by the U.S. Department of Energy (DOE), has progressed through the completion of its proof-of-concept (POC) phase at the 50 MWt Component Development and Integration Facility (CDIF) and 28 MWt Coal Fired Flow Facility (CFFF), thereby, providing the basis for demonstration and further commercial development and application of the technology. The conceptual design of a retrofit coal-fired MHD generating plant was originally completed by the MHD Development Corporation (MDC) under this Contract, DE-AC22-87PC79669. Thereafter, this concept was updated and changed to a stand-alone MHD demonstration facility and submitted by MDC to DOE in response to the fifth round of solicitations for Clean Coal Technology. Although not selected, that activity represents the major interest in commercialization by the developing industry and the type of demonstration that would be eventually necessary. This report updates the original executive summary of the conceptual design by incorporating the results of the POC program as well as MDC`s proposed Billings MHD Demonstration Project (BMDP) and outlines the steps necessary for commercialization.

NONE

1994-06-01T23:59:59.000Z

442

Building 32 35 Building 36  

E-Print Network [OSTI]

Building 10 Building 13 Building 7 LinHall Drive Lot R10 Lot R12 Lot 207 Lot 209 LotR9 Lot 205 Lot 203 LotBuilding30 Richland Avenue 39 44 Building 32 35 Building 36 34 Building 18 Building 19 11 12 45 29 15 Building 5 8 9 17 Building 16 6 Building 31 Building 2 Ridges Auditorium Building 24 Building 4

Botte, Gerardine G.

443

Ventilation and Infiltration in High-Rise Apartment Buildings Richard C. Diamond, Helmut E. Feustel and Darryl J. Dickerhoff  

E-Print Network [OSTI]

-rise apartment buildings. 1.0. Introduction & Literature Review Quantifying the impact of infiltration on energy annual energy consumption per floor in a 12-story apartment building in Pittsburgh, Pennsylvania, these findings have more general implications for energy retrofits and health and comfort of occupants in high

Diamond, Richard

444

Sonoma House: Monitoring of the First U.S. Passive House Retrofit  

SciTech Connect (OSTI)

The Sonoma Deep Retrofit is a single-story deep retrofit project in the marine climate of Sonoma, California. The design was guided by Passive House principles which promote the use of very high levels of wall, ceiling, and floor insulation along with tight envelope construction to maintain a comfortable indoor environment with little or no need for conventional heating or cooling.

German, A.; Weitzel, B.; Backman, C.; Hoeschele, M.; Dakin, B.

2012-12-01T23:59:59.000Z

445

Using Auxiliary Gas Power for CCS Energy Needs in Retrofitted Coal Power Plants  

E-Print Network [OSTI]

1 Using Auxiliary Gas Power for CCS Energy Needs in Retrofitted Coal Power Plants by Sarah Bashadi and Policy Program #12;2 #12;3 Using Auxiliary Gas Power for CCS Energy Needs in Retrofitted Coal Power, a significant amount of excess power was produced using both gas turbine configurations. This excess power could

446

Air Leakage of US Homes: Regression Analysis and Improvements from Retrofit  

E-Print Network [OSTI]

Air Leakage of US Homes: Regression Analysis and Improvements from Retrofit Wanyu R. Chan, Jeffrey,000 single-family detached homes have sufficient information for the analysis of air leakage in relation variability in normalized leakage. ResDB also contains the before and after retrofit air leakage measurements

447

An Evaluation of Energy-Saving Retrofits from the Texas LoanSTAR Program  

E-Print Network [OSTI]

This report discusses the LoanSTAR retrofit savings through December 1993 with an emphasis on the Constant Volume to Variable Air Volume air-handler retrofits. The report also summarizes several key findings about the LoanSTAR program which has 70...

Haberl, J. S.; Claridge, D. E.; Heneghan, T.; Sieggreen, R.; Sims, J.

1996-01-01T23:59:59.000Z

448

Presented at the U.S. Green Buildings Council Third Annual Conference, San Diego, CA, November 17-19, 1996. The research reported here was funded, in part, by the California Institute for Energy Efficiency (CIEE), a research  

E-Print Network [OSTI]

Pollution Prevention Division. Interoperable, Life-cycle Tools for Assuring Building Performance to the structure of the building industry, the numerous people and companies involved in the process, the current design and construction are completed. We suggest that new interoperable software tools could greatly

449

Appendices of an appraisal for the use of geothermal energy in state-owned buildings in Colorado. Section A. Alamosa  

SciTech Connect (OSTI)

Two state-owned building complexes have been evaluated within the city of Alamosa: Adams State College and the State Highway Department Buildings. The resource assessment in dicates that 150/sup 0/F may be available at flow rates of 1000 gpm per well, depths of 4000 feet, and possibly under Artesian pressure. Two building retrofit engineering options are evaluated for Adams State College, both of which assume only partial replacement (approximately 50%) of the existing natural-gas-fired steam-boiler system. The two retrofit options for goethermal heating include (1) a high performance central heat pump for boosting the circulating heat water to 200/sup 0/F for space heating and (2) a central heat exchanger for delivery of heating water at 145/sup 0/F. The first option provides for continued usage of the existing hot water heating units in the campus buildings, with the exception of retrofit of the steam units in College Center. The second option provides for the addition of terminal hot water heating units in all of the buildings in order to adapt to 145/sup 0/F heating water. Retrofit engineering for the State Highway Department Buildings provides for the use of a central heat exchanger and the distribution of 140/sup 0/F heating water to all building areas that are presently heated.

Meyer, R.T.; Coe, B.A.; Dick, J.D.

1981-01-01T23:59:59.000Z

450

Whole-Building and Community Integration Group The Whole-Building and Community Integration Group (WBCI) supports the U.S. Department of Energy's (DOE's) goals  

E-Print Network [OSTI]

of Energy, designed to accelerate the development and adoption of advanced building energy technologies Retrofits with Energy Savings greater than 30% By partnering with utilities and local contractors, ORNL practitioners in their application. Staff accomplishments include development of the first-ever energy model

Oak Ridge National Laboratory

451

Glove port retrofit assembly and method of replacing components  

DOE Patents [OSTI]

What is disclosed is a system for retrofitting a sealed enclosure for performing work therein having an outer enclosure assembly configured to be clamped to the outer annular face of a port ring and form a sealed engagement with the outer annular surface of the port ring, a change assembly having an inner ring and an access element wherein the inner ring has a first annular cylinder body that is sized to be slidably received by the port ring and the access element is configured to be sealably and slidably positioned within the first annular cylinder body of the inner ring.

Giesen, Isaac M; Cournoyer, Michael E; Rael, David G

2014-11-18T23:59:59.000Z

452

MHD (magnetohydrodynamics) retrofit of a coal-fired generating plant  

SciTech Connect (OSTI)

This report presents the following appendices on the design of a coal-fired MHD retrofit: AVCO part load study; AVCO full load calculations; MSE mass balance calculations; Corette/MHD combined plant overall efficiency estimate; Corette boiler efficiency estimate; dynamic modeling and control simulation; combustor and nozzle scaling approach; field inductance and energy calculations; diagnostic instrumentation listing; equipment list; cost estimate factors; equipment and vendor costs data; CFFF test information; HRSR-ESP seed/ash calculations; and K{sub 2}/S molar ratio.

Not Available

1989-01-01T23:59:59.000Z

453

Retrofit Analysis of Older, Single Family Housing in San Antonio  

E-Print Network [OSTI]

Retrofit Analysis of Older, Single Family Housing in San Antonio Hazem Rashed-Ali, PhD, University of Texas at San Antonio CATEE 2013 Clean Air Through Energy Efficiency Conference December 16-18, 2013 San Antonio, TX 12/17/2013 ESL-KT-13...-12-05 CATEE 2013: Clean Air Through Energy Efficiency Conference, San Antonio, Texas Dec. 16-18 Background • Approximately one third of all residential housing units in US (about 40 million) were built before 1960 ( American Housing Survey, 2008), • City...

Rashed-Ali, H.

2013-01-01T23:59:59.000Z

454

Retrofit Energy Savings Estimation Model | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating Solar PowerstoriesNrelPartnerType Jump to:CoStrategies (EC-LEDS) | OpentopicsRetrofit

455

Retrofit Ramp-Up Selected Projects* | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAXBalancedDepartmentRestrictions on Federal Employees AcceptanceRetrofit Ramp-Up

456

NREL Job Task Analysis: Retrofit Installer Technician (Revised)  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Careerlumens_placard-green.eps MoreWSRC-STI-2007-00250ThisMarsh More DocumentsNOWEGISfromRetrofit

457

Oklahoma Opportunity Fund (Oklahoma)  

Broader source: Energy.gov [DOE]

The Oklahoma Opportunity Fund was established to promote economic development and related infrastructure development. Eligible applicants are for-profit entities; non-profit entities; and state and...

458

Energy Efficiency Fund  

Broader source: Energy.gov [DOE]

Connecticut's original electric-industry restructuring legislation (Public Act 98-28), enacted in April 1998, created separate funds to support energy efficiency and renewable energy.* The...

459

RM12-2703 Advanced Rooftop Unit Control Retrofit Kit Field Demonstration: Hawaii and Guam Energy Improvement Technology Demonstration Project  

SciTech Connect (OSTI)

As part of its overall strategy to meet its energy goals, the Naval Facilities Engineering Command (NAVFAC) partnered with U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to rapidly demonstrate and deploy cost-effective renewable energy and energy efficiency technologies. This was one of several demonstrations of new and underutilized commercial energy efficiency technologies. The consistent year-round demand for air conditioning and dehumidification in Hawaii provides an advantageous demonstration location for advanced rooftop control (ARC) retrofit kits to packaged rooftop units (RTUs). This report summarizes the field demonstration of ARCs installed on nine RTUs serving a 70,000-ft2 exchange store (large retail) and two RTUs, each serving small office buildings located on Joint Base Pearl Harbor-Hickam (JBPHH).

Doebber, I.; Dean, J.; Dominick, J.; Holland, G.

2014-03-01T23:59:59.000Z

460

Forward Funding Why is Forward Funding useful for project  

E-Print Network [OSTI]

and administrative risks to the University. Forward funding chartstrings ordinarily will be created when: · allForward Funding - 1 - Why is Forward Funding useful for project management? Forward funding. For continuing year budget segments, forward funding helps ensure (i) the timely management of payroll or other

Mather, Patrick T.

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

AVAILABLE NOW! Biomass Funding  

E-Print Network [OSTI]

AVAILABLE NOW! Biomass Funding Guide 2010 The Forestry Commission and the Humber Rural Partnership (co-ordinated by East Riding of Yorkshire Council) have jointly produced a biomass funding guide fuel prices continue to rise, and the emerging biomass sector is well-placed to make a significant

462

A Practical Guide for Commissioning Existing Buildings  

SciTech Connect (OSTI)

Although this guide focuses on the retrocommissioning process and its advantages, all three types of commissioning--retrocommissioning, commissioning, and recommissioning--play an equally important role in ensuring that buildings perform efficiently and provide comfortable, safe, and productive work environments for owners and occupants. For new construction and retrofit projects, commissioning should be incorporated early, during design, and last throughout the length of the project. For buildings that were never commissioned, the retrocommissioning process can yield a wealth of cost-saving opportunities while enhancing a building's environment. Finally, once a building is commissioned or retrocommissioned, incorporating recommissioning into the organization's O and M program (by periodically reapplying the original diagnostic testing and checklist procedures) helps ensure that cost savings and other benefits gained from the original process persist over time.

Haasl, T.; Sharp, T.

1999-04-01T23:59:59.000Z

463

Improving Building Energy Simulation Programs Through Diagnostic Testing (Fact Sheet)  

SciTech Connect (OSTI)

New test procedure evaluates quality and accuracy of energy analysis tools for the residential building retrofit market. Reducing the energy use of existing homes in the United States offers significant energy-saving opportunities, which can be identified through building simulation software tools that calculate optimal packages of efficiency measures. To improve the accuracy of energy analysis for residential buildings, the National Renewable Energy Laboratory's (NREL) Buildings Research team developed the Building Energy Simulation Test for Existing Homes (BESTEST-EX), a method for diagnosing and correcting errors in building energy audit software and calibration procedures. BESTEST-EX consists of building physics and utility bill calibration test cases, which software developers can use to compare their tools simulation findings to reference results generated with state-of-the-art simulation tools. Overall, the BESTEST-EX methodology: (1) Tests software predictions of retrofit energy savings in existing homes; (2) Ensures building physics calculations and utility bill calibration procedures perform to a minimum standard; and (3) Quantifies impacts of uncertainties in input audit data and occupant behavior. BESTEST-EX is helping software developers identify and correct bugs in their software, as well as develop and test utility bill calibration procedures.

Not Available

2012-02-01T23:59:59.000Z

464

Intelligent Controls for Net-Zero Energy Buildings  

SciTech Connect (OSTI)

The goal of this project is to develop and demonstrate enabling technologies that can empower homeowners to convert their homes into net-zero energy buildings in a cost-effective manner. The project objectives and expected outcomes are as follows: • To develop rapid and scalable building information collection and modeling technologies that can obtain and process “as-built” building information in an automated or semiautomated manner. • To identify low-cost measurements and develop low-cost virtual sensors that can monitor building operations in a plug-n-play and low-cost manner. • To integrate and demonstrate low-cost building information modeling (BIM) technologies. • To develop decision support tools which can empower building owners to perform energy auditing and retrofit analysis. • To develop and demonstrate low-cost automated diagnostics and optimal control technologies which can improve building energy efficiency in a continual manner.

Li, Haorong; Cho, Yong; Peng, Dongming

2011-10-30T23:59:59.000Z

465

Test Methods and Protocols for Environmental and Safety Hazards Associated with Home Energy Retrofits  

SciTech Connect (OSTI)

A number of health hazards and hazards to the durability of homes may be associated with energy retrofitting and home renovation projects. Among the hazards associated with energy retrofit work, exposure to radon is thought to cause more than 15,000 deaths per year in the U.S., while carbon monoxide poisoning results in about 20,000 injuries and 450 deaths per year. Testing procedures have been developed for identifying and quantifying hazards during retrofitting. These procedures commonly include a battery of tests to screen combustion appliances for safe operation, including worst case depressurization measurement, backdrafting (spillage) under depressurized or normal conditions, and carbon monoxide production.

Cautley, D.; Viner, J.; Lord, M.; Pearce, M.

2012-12-01T23:59:59.000Z

466

Cedarville School District Retrofit of Heating and Cooling Systems with Geothermal Heat Pumpsand Ground Source Water Loops  

Broader source: Energy.gov [DOE]

Project objectives: Improve the indoor air quality and lower the cost of cooling and heating the buildings that make up the campus of Cedarville High School and Middle School.; Provide jobs; and reduce requirements of funds for the capital budget of the School District; and thus give relief to taxpayers in this rural region during a period of economic recession.

467

Small Enterprise Growth Fund (Maine)  

Broader source: Energy.gov [DOE]

The Small Enterprise Growth Fund is a professionally-managed venture capital fund that invests in Maine companies which demonstrate high potential for growth and public benefit. The fund has...

468

Building Energy Audit Report, for Hickam AFB, HI  

SciTech Connect (OSTI)

A building energy assessment was performed by a team of engineers from Pacific Northwest National Laboratory (PNNL) under contract to the Department of Energy/Federal Energy Management program (FEMP). The effort used the Facility Energy Decision System (FEDS) model to determine how energy is consumed at Hickam AFB, identify the most cost-effective energy retrofit measures, and calculate the potential energy and cost savings. This documents reports the results of that assessment.

Chvala, William D.; De La Rosa, Marcus I.; Brown, Daryl R.; Dixon, Douglas R.

2010-09-30T23:59:59.000Z

469

Sustainable Energy Fund (Metropolitan Edison)  

Broader source: Energy.gov [DOE]

FirstEnergy (formerly GPU) established the Metropolitan Edison Company Sustainable Energy Fund and the Penelec Sustainable Energy Fund in 2000. The Community Foundation for the Alleghenies in...

470

Building Stones  

E-Print Network [OSTI]

3). Photographs by the author. Building Stones, Harrell, UEEOxford Short Citation: Harrell, 2012, Building Stones. UEE.Harrell, James A. , 2012, Building Stones. In Willeke

2012-01-01T23:59:59.000Z

471

Texas Capital Fund (Texas)  

Broader source: Energy.gov [DOE]

The Texas Capital Fund is designed to promote growth in rural non-entitlement areas, generally defined as cities with less than 50,000 residents or counties with less than 200,000 residents....

472

Sustainable Energy Trust Fund  

Broader source: Energy.gov [DOE]

The District of Columbia's Retail Electric Competition and Consumer Protection Act of 1999 required the DC Public Service Commission (PSC) to establish a public benefits fund to provide energy...

473

Renewable Development Fund (RDF)  

Broader source: Energy.gov [DOE]

Xcel Energy's Renewable Development Fund (RDF) was created in 1999 pursuant to the 1994 Radioactive Waste Management Facility Authorization Law (Minn. Stat. § 116C.779). Originally, Xcel Energy was...

474

Community Development Fund (Illinois)  

Broader source: Energy.gov [DOE]

The Community Development Fund is a partnership between the Illinois Department of Commerce and Economic Opportunity (DCEO) and financial institutions. Up to $5 million in micro loans is available...

475

Green Energy Fund  

Broader source: Energy.gov [DOE]

'''''Note: The Green Energy Fund regulations are currently under revision to improve program function and meet the requirements of the Delaware Energy Act. The Delaware Division of Energy and...

476

Rural Innovation Fund (Kentucky)  

Broader source: Energy.gov [DOE]

This fund provides capital to early-stage technology companies located in rural areas of Kentucky. Companies may apply for a $30,000 grant or an investment up to $100,000.

477

Green Buildings  

SciTech Connect (OSTI)

This award was split into five tasks, HVAC replacement, lighting retrofitting, daylight harvesting, data center virtualization, and traffic signal retrofitting. The first three tasks were combined into an Energy Performance Contract on seven City facilities. This allowed for the total cost of the project to be offset by guaranteed savings over a 14 year period. The other two projects where done by separate vendors and successfully completed. The combination of these five tasks will result in a significant reduction in our energy consumption city wide, and will also translate to savings for the taxpayer on utility costs. There were also additional financial savings to the taxpayer not related to energy reduction that added value to these projects which will be discussed below.

Ruppert, Benjamin; Elliot, Phillip

2012-08-15T23:59:59.000Z

478

Distribution and Room Air Mixing Risks to Retrofitted Homes  

SciTech Connect (OSTI)

?Energy efficiency upgrades reduce heating and cooling loads on a house. With enough load reduction and if the HVAC system warrants replacement, the HVAC system is often upgraded with a more efficient, lower capacity system that meets the loads of the upgraded house. For a single-story house with ceiling supply air diffusers, ducts are often removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling.

Burdick, A.

2014-12-01T23:59:59.000Z

479

Indoor Air Quality and Ventilation in Residential Deep Energy Retrofits  

SciTech Connect (OSTI)

Because airtightening is a significant part of Deep Energy Retrofits (DERs), concerns about ventilation and Indoor Air Quality (IAQ) have emerged. To investigate this, ventilation and IAQ were assessed in 17 non-smoking California Deep Energy Retrofit homes. Inspections and surveys were used to assess household activities and ventilation systems. Pollutant sampling performed in 12 homes included six-day passive samples of nitrogen dioxide (NO2), formaldehyde and air exchange rate (AER); time-resolved data loggers were used to measure particle counts. Half of the homes provided continuous mechanical ventilation. Despite these homes being twice as airtight (3.0 and 7.6 ACH50, respectively), their median AER was indistinguishable from naturally vented homes (0.36 versus 0.37 hr--1). Numerous problems were found with ventilation systems; however, pollutant levels did not reach levels of concern in most homes. Ambient NO2 standards were exceeded in some gas cooking homes that used legacy ranges with standing pilots, and in Passive House-style homes without range hoods exhausted to outside. Cooking exhaust systems were installed and used inconsistently. The majority of homes reported using low-emitting materials, and formaldehyde levels were approximately half those in conventional new CA homes (19.7 versus 36 ?g/m3), with emissions rates nearly 40percent less (12.3 versus 20.6 ?g/m2/hr.). Presence of air filtration systems led to lower indoor particle number concentrations (PN>0.5: 8.80E+06 PN/m3 versus 2.99E+06; PN>2.5: 5.46E+0.5 PN/m3 versus 2.59E+05). The results indicate that DERs can provide adequate ventilation and IAQ, and that DERs should prioritize source control, particle filtration and well-designed local exhaust systems, while still providing adequate continuous ventilation.

Less, Brennan; Walker, Iain

2014-06-01T23:59:59.000Z

480

Effects of Catalysts on Emissions from Heavy-Duty Diesel Retrofits...  

Broader source: Energy.gov (indexed) [DOE]

9 Directions in Engine-Efficiency and Emissions Research (DEER) Conference Dearborn, Michigan, August 3-6, 2009 Effects of Catalysts on Emissions from Heavy-Duty Diesel Retrofits...

Note: This page contains sample records for the topic "fund building retrofit" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Trial Demonstration of Area Lighting Retrofit: Yuma Border Patrol, Yuma Arizona  

SciTech Connect (OSTI)

The Yuma Sector Border Patrol Area is a high flux lighting application in a high temperature environment, presenting a formidable challenge for light-emitting diodes (LEDs). This retrofit is an Energy Savings Performance Contract ENABLE project under the U.S. Department of Energy (DOE) Federal Energy Management Program. If high flux LED technology performs well in a region with high ambient temperature and solar radiation, it can perform well in most outdoor environments. The design process for the Yuma retrofit has already provided valuable knowledge to CBP and DOE. The LED lighting system selected for the retrofit is expected to reduce energy consumption 69% compared to the incumbent quartz metal halide (QMH) lighting system. If the LED lighting system is installed, GATEWAY will continue to document and disseminate information regarding the installation and long-term performance so that others may also gain valuable knowledge from the Yuma Sector Border Patrol Area lighting retrofit.

Wilkerson, Andrea M.; McCullough, Jeffrey J.

2014-12-30T23:59:59.000Z

482

Pre-Retrofit Lighting Study at the University of Texas at Arlington, Texas  

E-Print Network [OSTI]

Audit Report for the site, completed in 1991, recommended a lighting retrofit that included delamping, relamping with high efficiency lamps, the installation of high efficiency electronic ballasts, and the installation of specular reflectors. However...

Houcek, J. K.; Claridge, D. E.; Haberl, J. S.

1993-01-01T23:59:59.000Z

483

Philadelphia Gas Works- Commercial and Industrial EnergySense Retrofit Program (Pennsylvania)  

Broader source: Energy.gov [DOE]

Philadelphia Gas Works' (PGW) Commercial and Industrial Retrofit Incentive Program is part of EnergySense, PGW’s portfolio of energy efficiency programs designed to help customers save energy and...

484

Using the Street and Parking Facility Lighting Retrofit Financial Analysis Tool  

Broader source: Energy.gov [DOE]

This August 22, 2013 webinar provided a guided walk-through of the Street and Parking Facility Lighting Retrofit Financial Analysis Tool. Developed by a partnership of the DOE Municipal Solid-State...

485

Webcast: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool  

Broader source: Energy.gov [DOE]

This April 3, 2012 webcast presented information about the Retrofit Financial Analysis Tool developed by DOE"s Municipal Solid-State Street Lighting Consortium. Doug Elliott of Pacific Northwest...

486

Retrofit and Testing of a Pre-Turbo, Diesel Oxidation Catalyst...  

Broader source: Energy.gov (indexed) [DOE]

Retrofit and Testing of a Pre-Turbo, Diesel Oxidation Catalyst on a Tier 0, SD60M Freight Locomotive Achieving Over 50% PM Reduction Don Newburry Research & Development Manager...

487

Seismic Assessment and Retrofit of Existing Multi-Column Bent Bridges  

E-Print Network [OSTI]

Seismic Assessment and Retrofit of Existing Multi-Column Bent Bridges By Cole C. Mc ................................................................................................................................... 6 Seismic Activity in Western Washington State Approach ­ Bridge Modeling .............................................11 Seismic Excitations

488

State-of-the-Art Thermal Energy Storage Retrofit at a Large Manufacturing Facility  

E-Print Network [OSTI]

This paper will describe the existing conditions, strategic planning, feasibility study, economic analysis, design, specification, construction, and project management for the 2.9 megawatt “full shift” chilled water thermal energy storage retrofit...

Fiorino, D.

489

Standard Measurement & Verification Plan for Lighting Equipment Retrofit or Replacement Projects  

SciTech Connect (OSTI)

This document provides a framework for a standard Measurement and Verification (M&V) plan for lighting projects. It was developed to support cost-effective retrofits (partial and complete replacements) of lighting systems and is intended to provide a foundation for an M&V plan for a lighting retrofit utilizing a "best practice" approach, and to provide guidance to site owners, contractors, and other involved organizations on what is essential for a robust M&V plan for lighting projects. This document provides examples of appropriate elements of an M&V plan, including the calculation of expected energy savings. The standard M&V plan, as provided, also allows for consistent comparison with other similar lighting projects. Although intended for lighting retrofit applications, M&V plans developed per this framework document may also be used for other non-lighting technology retrofits and new installations.

Richman, Eric E.

2009-11-04T23:59:59.000Z

490

Effects of moisture on debonding in FRP-retrofitted concrete systems  

E-Print Network [OSTI]

FRP (fiber reinforced polymer) retrofit systems for reinforced concrete (RC) structures have been widely used in the past 10 years, and numerous studies on its short-term debonding behavior have been conducted extensively. ...

Tuakta, Chakrapan, 1980-

2011-01-01T23:59:59.000Z

491

Using auxiliary gas power for CCS energy needs in retrofitted coal power plants  

E-Print Network [OSTI]

Post-combustion capture retrofits are expected to a near-term option for mitigating CO 2 emissions from existing coal-fired power plants. Much of the literature proposes using power from the existing coal plant and thermal ...

Bashadi, Sarah (Sarah Omer)

2010-01-01T23:59:59.000Z

492

Joint China-United States Report for Year 1 Insulation Materials and Systems Project Area Clean Energy Research Center Building Energy Efficiency (CERC-BEE)  

SciTech Connect (OSTI)

In November of 2009, the presidents of China and the U.S. announced the establishment of the Clean Energy Research Center (CERC). This broad research effort is co-funded by both countries and involves a large number of research centers and universities in both countries. One part of this program is focused on improving the energy efficiency of buildings. One portion of the CERC-BEE was focused on building insulation systems. The research objective of this effort was to Identify and investigate candidate high performance fire resistant building insulation technologies that meet the goal of building code compliance for exterior wall applications in green buildings in multiple climate zones. A Joint Work Plan was established between researchers at the China Academy of Building Research and Oak Ridge National Laboratory. Efforts in the first year under this plan focused on information gathering. The objective of this research program is to reduce building energy use in China via improved building insulation technology. In cold regions in China, residents often use inefficient heating systems to provide a minimal comfort level within inefficient buildings. In warmer regions, air conditioning has not been commonly used. As living standards rise, energy consumption in these regions will increase dramatically unless significant improvements are made in building energy performance. Previous efforts that defined the current state of the built environment in China and in the U.S. will be used in this research. In countries around the world, building improvements have typically followed the implementation of more stringent building codes. There have been several changes in building codes in both the U.S. and China within the last few years. New U.S. building codes have increased the amount of wall insulation required in new buildings. New government statements from multiple agencies in China have recently changed the requirements for buildings in terms of energy efficiency and fire safety. A related issue is the degree to which new standards are adopted and enforced. In the U.S., standards are developed using a consensus process, and local government agencies are free to implement these standards or to ignore them. For example, some U.S. states are still using 2003 versions of the building efficiency standards. There is also a great variation in the degree to which the locally adopted standards are enforced in different U.S. cities and states. With a more central process in China, these issues are different, but possible impacts of variable enforcement efficacy may also exist. Therefore, current building codes in China will be compared to the current state of building fire-safety and energy-efficiency codes in the U.S. and areas for possible improvements in both countries will be explored. In particular, the focus of the applications in China will be on green buildings. The terminology of 'green buildings' has different meanings to different audiences. The U.S. research is interested in both new, green buildings, and on retrofitting existing inefficient buildings. An initial effort will be made to clarify the scope of the pertinent wall insulation systems for these applications.

Stovall, Therese K [ORNL; Biswas, Kaushik [ORNL; Song, Bo [China Academy of Building Research; Zhang, Sisi [China Academy of Building Research

2012-08-01T23:59:59.000Z

493

Multifamily Retrofit Project Manager Job/Task Analysis and Report: September 2013  

SciTech Connect (OSTI)

The development of job/task analyses (JTAs) is one of three components of the Guidelines for Home Energy Professionals project and will allow industry to develop training resources, quality assurance protocols, accredited training programs, and professional certifications. The Multifamily Retrofit Project Manager JTA identifies and catalogs all of the tasks performed by multifamily retrofit project managers, as well as the knowledge, skills, and abilities (KSAs) needed to perform the identified tasks.

Owens, C. M.

2013-09-01T23:59:59.000Z

494

Retrofitting the domestic built environment: investigating household perspectives towards energy efficiency technologies and behaviour  

E-Print Network [OSTI]

]. Retrofitting homes is a complex task con- flated by multiple factors, ranging from pure economics to subjective psychology [Dixon & Eames, 2013; Institution of Mechanical Engineers, 2009; Kelly, 2009; Lior, 2010; Stafford et al., 2012]. Such complexity invites... cultural heritage research, and geo-technical soil surveying. Therefore, in order to delimit a more focused scope 3 1. Introduction of research, this thesis specifically investigated improving the uptake of energy ef- ficiency retrofits in the domestic...

Pelenur, Marcos

2014-03-04T23:59:59.000Z

495

Calculating Energy and Demand Retrofit Savings for Victoria High School: Interim Report  

E-Print Network [OSTI]

ESL-TR-92/12-03 Calculating Energy and Demand Retrofit Savings For Victoria High School Yue Liu, T. Agami Reddy, S. Katipamula and David E. Claridge. Interim Report Energy Systems Laboratory Texas A&M University College Station, TX 77843 December... 1992 Calculating Energy and Demand Retrofit Savings For Victoria High School Yue Liu, T. Agami Reddy, S. Katipamula and David E. Claridge. Interim Report Energy Systems Laboratory Texas A&M University College Station, TX 77843 December 1992 Abstract...

Liu, Y.; Reddy, T. A.; Katipamula, S.; Claridge, D. E.

1992-01-01T23:59:59.000Z

496

Building Technologies Program - 1995 Annual Report  

E-Print Network [OSTI]

Integrated Design," Pro- ceedings of 15th Passive Solardesign guidance for the optimal utiliza- tion of passive solarDesign Tool for Small Commercial Buildings A DOE-funded industry/laboratory collaboration between the Passive Solar

Selkowitz, S.E.

2010-01-01T23:59:59.000Z

497

Updating Texas Energy Cost Containment Audit Reports  

E-Print Network [OSTI]

In 1984 and 1986, 35.3 million square feet of state owned buildings were audited to identify cost saving retrofit projects. Originally intended for direct legislative funding or bond sales, funding became available in 1989 through oil overcharge...

Burke, T. E.; Heffington, W. M.

1989-01-01T23:59:59.000Z

498

Energy Retrofit Field Study and Best Practices in a Hot-Humid Climate  

SciTech Connect (OSTI)

Energy efficiency improvement as a component of comprehensive renovation was investigated under U.S. Department of Energy (DOE) funding of the Building America Partnership for Improved Residential Construction (BA-PIRC). Researchers at the Florida Solar Energy Center (FSEC) worked with affordable housing partners renovating foreclosed homes built from the 1950's through the 2000's in the hot-humid climate (within the Southern census region), primarily in Florida. Researchers targeted a 30% improvement in whole-house energy efficiency along with the health and safety, durability, and comfort guidelines outlined in DOE's Builders Challenge Program (Version 1) Quality Criteria.

McIvaine, J.; Sutherland, K.; Martin, E.

2013-03-01T23:59:59.000Z

499

Funding Formulas and Arrangements under IEA Implementing Agreements  

SciTech Connect (OSTI)

The Pacific Northwest National Laboratory has researched how participating countries divide funding obligations under International Energy Agency (IEA) Implementing Agreements (IAs). This is part of a broader assessment evaluating the buildings-area IAs. This particular part of the analysis looked at 12 IAs funded by the U.S. Department of Energy. By selecting a range of agreements, we hoped to understand the types of arrangements and the range of funding formulas. PNNL asked the U.S. Executive Committee (ExCo) members how the total contribution for their IA and its Annexes were determined, and how the total was then divided between participating countries.

Delgado, Alison; Evans, Meredydd

2008-12-30T23:59:59.000Z

500

Autotune E+ Building Energy Models  

SciTech Connect (OSTI)

This paper introduces a novel Autotune methodology under development for calibrating building energy models (BEM). It is aimed at developing an automated BEM tuning methodology that enables models to reproduce measured data such as utility bills, sub-meter, and/or sensor data accurately and robustly by selecting best-match E+ input parameters in a systematic, automated, and repeatable fashion. The approach is applicable to a building retrofit scenario and aims to quantify the trade-offs between tuning accuracy and the minimal amount of ground truth data required to calibrate the model. Autotune will use a suite of machine-learning algorithms developed and run on supercomputers to generate calibration functions. Specifically, the project will begin with a de-tuned model and then perform Monte Carlo simulations on the model by perturbing the uncertain parameters within permitted ranges. Machine learning algorithms will then extract minimal perturbation combinations that result in modeled results that most closely track sensor data. A large database of parametric EnergyPlus (E+) simulations has been made publicly available. Autotune is currently being applied to a heavily instrumented residential building as well as three light commercial buildings in which a de-tuned model is autotuned using faux sensor data from the corresponding target E+ model.

New, Joshua Ryan [ORNL; Sanyal, Jibonananda [ORNL; Bhandari, Mahabir S [ORNL; Shrestha, Som S [ORNL

2012-01-01T23:59:59.000Z