National Library of Energy BETA

Sample records for fr ro om

  1. ARM - Instrument - om

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Instrument : Ozone Monitoring Instrument (OM) <-- Picture of the Ozone Monitoring Instrument (OMI) --> General Overview The Ozone Monitoring Instrument (OMI) distinguishes between ...

  2. ERYLFIUM OM PANY

    Office of Legacy Management (LM)

    ERYLFIUM OM PANY 3714 CI-XIESTER /%"EXUE J &CO-74 -L;s C+SSIFICATION CANCELLED OR April 22, 1947 Dear 3. 3elmore: Xith reference to Contract X- 7401 ens 78, supp1emstit 11 calJi?Jg for 5000 pounds of SP ?eO 1350X, we have shipped 5000 pounds to the A. C. Spark E' lU~ co. in i?int i~i0hige.n. There were two s!lipi%ents made against this order. GE/L Kc. The first shipmast was ;lade on i.i)ril 12, ,A947 via ~rnili7c.y eqress on K,' -23305 copies .;; -"5 and ~$7 of which are enclosed.

  3. Reliability, O&M, Standards Development

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reliability, O&M, Standards Development - Sandia Energy Energy Search Icon Sandia Home ... Twitter Google + Vimeo GovDelivery SlideShare Reliability, O&M, Standards Development ...

  4. OM300 Direction Drilling Module

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    MacGugan, Doug

    2013-08-22

    OM300 – Geothermal Direction Drilling Navigation Tool: Design and produce a prototype directional drilling navigation tool capable of high temperature operation in geothermal drilling Accuracies of 0.1° Inclination and Tool Face, 0.5° Azimuth Environmental Ruggedness typical of existing oil/gas drilling Multiple Selectable Sensor Ranges High accuracy for navigation, low bandwidth High G-range & bandwidth for Stick-Slip and Chirp detection Selectable serial data communications Reduce cost of drilling in high temperature Geothermal reservoirs Innovative aspects of project Honeywell MEMS* Vibrating Beam Accelerometers (VBA) APS Flux-gate Magnetometers Honeywell Silicon-On-Insulator (SOI) High-temperature electronics Rugged High-temperature capable package and assembly process

  5. Spring O&M Users Group Meeting

    Broader source: Energy.gov [DOE]

    The spring 2015 UVIG O&M User Group meeting will feature a plenary session focused on blade inspection best practices.  The UVIG membership will hear presentations from:

  6. Property List for RO Code '37', EDI

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    8/12 Property List for RO Code '37', EDI 1 Total Property Cost BARCODE DESCRIPTION MFR. MODEL_NO SN COST BLDG ROOM 0000001264 15HP AIR COMPRESSOR CHAMPION 15WTS55A WTS-A4358 $12,000.00 OFF ROCKS 0000001262 15HP AIR COMPRESSOR CHAMPION 15WTS55A WTS-A4786 $20,000.00 OFF ROCKS 0000001265 15HP COMPRESSOR CHAMPION 15WTS55A WTS-A-4133 $12,000.00 OFF ROCKS 0000001261 50HP COMPRESSOR (OIL KOBELCO KNWAO/B-H 02H0338 $50,000.00 OFF ROCKS 0199329 ANALYZER POWER QUALI DRANETZ TECH IN 658 NA020C034 $14,445.66

  7. AWEA Wind Project O&M and Safety Seminar

    Broader source: Energy.gov [DOE]

    The AWEA Wind Project O&M and Safety Seminar is where leading owners, operators, turbine manufacturers, material suppliers, wind technicians, managers, supervisors, engineers, and occupational...

  8. Om Sakthi Wind Power Pvt Ltd | Open Energy Information

    Open Energy Info (EERE)

    Sakthi Wind Power Pvt Ltd Jump to: navigation, search Name: Om Sakthi Wind Power Pvt. Ltd. Place: Chennai, Tamil Nadu, India Sector: Wind energy Product: Chennai-based wind project...

  9. AWEA Wind Project O&M and Safety Conference 2016

    Broader source: Energy.gov [DOE]

    The American Wind Energy Association Wind Project O&M and Safety Conference is where leading owners, operators, turbine manufacturers, material suppliers, wind technicians, managers,...

  10. Perlick: ENERGY STAR Referral (HP48RO-S)

    Broader source: Energy.gov [DOE]

    DOE referred Perlick refrigerator HP48RO-S to EPA, brand manager of the ENERGY STAR program, for appropriate action after DOE testing revealed that the model does not meet ENERGY STAR requirements.

  11. ARM - VAP Product - mmcrmode4ro200309091cloth

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ro200309091cloth Documentation Data Management Facility Plots (Quick Looks) Citation DOI: 10.5439/1027356 [ What is this? ] Generate Citation ARM Data Discovery Browse Data Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send VAP Output : MMCRMODE4RO200309091CLOTH ARSCL: derived, MMCR Mode 4 (robust mode) moments Active Dates 2003.09.27 - 2004.08.10

  12. Ingenieurb ro f r Energieanlagen IBE | Open Energy Information

    Open Energy Info (EERE)

    f r Energieanlagen IBE Jump to: navigation, search Name: Ingenieurbro fr Energieanlagen (IBE) Place: Bad Nauheim, Germany Zip: 61231 Sector: Services, Solar, Wind energy...

  13. OM Code Requirements For MOVs -- OMN-1 and Appendix III

    SciTech Connect (OSTI)

    Kevin G. DeWall

    2011-08-01

    The purpose or scope of the ASME OM Code is to establish the requirements for pre-service and in-service testing of nuclear power plant components to assess their operational readiness. For MOVs this includes those that perform a specific function in shutting down a reactor to the safe shutdown condition, maintaining the safe shutdown condition, and mitigating the consequences of an accident. This paper will present a brief history of industry and regulatory activities related to MOVs and the development of Code requirements to address weaknesses in earlier versions of the OM Code. The paper will discuss the MOV requirements contained in the 2009 version of ASME OM Code, specifically Mandatory Appendix III and OMN-1, Revision 1.

  14. AmeriFlux US-Ro1 Rosemount- G21

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Baker, John [USDA-ARS; Griffis, Tim [University of Minnesota; Griffis, Timothy [University of Minnesota

    2016-01-01

    This is the AmeriFlux version of the carbon flux data for the site US-Ro1 Rosemount- G21. Site Description - This tower is located in a farm field farmed in accordance with the dominant farming practice in the region: a corn/soybean rotation with chisel plow tillage in the fall following corn harvest and in the spring following soybeans.

  15. AmeriFlux US-Ro3 Rosemount- G19

    SciTech Connect (OSTI)

    Baker, John; Griffis, Tim

    2016-01-01

    This is the AmeriFlux version of the carbon flux data for the site US-Ro3 Rosemount- G19. Site Description - This tower is located in a farm field farmed in accordance with the cominant farming practice in the region: a corn/soybean rotation with chisel plow tillage in the fall following corn harvest and in the spring following soybeans.

  16. AWEA O&M Recommended Practices Series Part VII: Wind Turbine...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AWEA O&M Recommended Practices Series Part VII: Wind Turbine Gear Lubricant Flushing Procedures AWEA O&M Recommended Practices Series Part VII: Wind Turbine Gear Lubricant Flushing...

  17. ARM - VAP Product - mmcrmode4ro200404141cloth

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    404141cloth Documentation Data Management Facility Plots (Quick Looks) Citation DOI: 10.5439/1027357 [ What is this? ] Generate Citation ARM Data Discovery Browse Data Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send VAP Output : MMCRMODE4RO200404141CLOTH ARSCL: derived, MMCR Mode 4 (robust mode) moments, 20040415 version Active Dates 2004.04.15 - 2007.11.27

  18. ARM - VAP Product - mmcrmode4ro200712011cloth

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    712011cloth Documentation Data Management Facility Plots (Quick Looks) Citation DOI: 10.5439/1027358 [ What is this? ] Generate Citation ARM Data Discovery Browse Data Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send VAP Output : MMCRMODE4RO200712011CLOTH ARSCL: derived, MMCR Mode 4 (robust mode) moments, 20071201 version Active Dates 2008.01.01 - 2011.03.23

  19. New directions and challenges for the O&M committee

    SciTech Connect (OSTI)

    Pelletier, J.P.

    1996-12-01

    In the second half of the decade of the nineties, the imperative of finding new ways to improve efficiency while maintaining safety is taking on a new urgency. The looming deregulation of the electric industry and the expected competition in the power production business fuels this urgency. The recently completed ASME research in the area of Risk-Based Inservice Testing offers the Operations and Maintenance (O&M) Committee an opportunity to meet this challenge. This opportunity, however, offers its own challenges. New ways of thinking about inservice testing and new technical skills will be needed to successfully incorporate this technology into Code documents. It will not be adequate to rely solely on incorporation of risk-based methods into the Code to meet this challenge. A thorough self assessment of what O&M does, how it is done, and the value added will help assure that the directions which are pursued do, indeed, meet the challenge ahead.

  20. Copy of Capitalized Property RO23_120213_1.xlsx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Capitalized Property 1 RO BARCODE DESCRIPTION MANUF. MODEL SN COST BLDG ROOM INVT_DATE 23 C5508 PRECISION ION POLISH GATAN INC 691 UNIT 427 01070301 $50,626.00 28 113 24-Sep-13 23 0000002116 TouchTable System TOUCHTABLE TT45 TT45S000378 $52,986.00 B03 134 19-Sep-13 23 0000002362 SYSTEM PUMP AMETEK Q AMETEK Q5000 CYL1A1308CYLIB1309CM $56,260.00 OFF TEXAS 11-Sep-12 23 0000000577 ANALYSIS SYSTEM BENC PFEIFFER GSD 301 C 44253789 $57,731.50 B25 115 30-Sep-13 23 0000002222 SLAVE NODES PSSC LABS PSSC

  1. Dual-purpose desalting, RO versus MSF an economic comparison

    SciTech Connect (OSTI)

    Brandt, D.C.; Battey, R.F.

    1983-01-01

    Capital and annual operating costs are estimated for producing water using three combinations of seawater reverse osmosis and gas turbines. The costs and operating parameters were developed for Middle East conditions assuming a Red Sea water source. The plants were designed to produce 37,850 m/sup 3//d (10 mgd) of potable water and to export 50,000 kW of power. The reverse osmosis plant utilizes energy recovery and was designed with full pretreatment for a surface water supply. Electricity is provided by either gas turbines, steam turbines, or combined cycle plants. Power and water costs developed for these systems were compared to costs for conventional, dual-purpose MSF/steam turbine plants for the same water and power production. These evaluations considered two levels of fuel costs. The results of this study show the significant effect of fuel costs on process selection and on water and power costs. Capital and operating costs were 20 to 28 percent less and 23 to 33 percent less, respectively, for the RO/gas turbine and RO/combined cycle plants as compared to conventional, dual-purpose MSF steam turbine plants. In addition to economics, the merits of the systems are discussed relative to delivery, ease and flexibility of operation, turndown capability, and so forth.

  2. O&M Best Practices - A Guide to Achieving Operational Efficiency (Release 2.0)

    SciTech Connect (OSTI)

    Sullivan, Gregory P.; Pugh, Ray; Melendez, Aldo P.; Hunt, W. D.

    2004-07-31

    This guide, sponsored by DOE's Federal Energy Management Program, highlights operations and maintenance (O&M) programs targeting energy efficiency that are estimated to save 5% to 20% on energy bills without a significant capital investment. The purpose of this guide is to provide the federal O&M energy manager and practitioner with useful information about O&M management, technologies, energy efficiency and cost-reduction approaches.

  3. OM300 -GeoThermal MWD Navigation Instrument | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    OM300 -GeoThermal MWD Navigation Instrument OM300 -GeoThermal MWD Navigation Instrument Develop a 300°C capable directional drilling navigation tool using Micro Electro-Mechanical Systems (MEMS) accelerometers and flux-gate magnetometers. high_macgugan_om300.pdf (857.64 KB) More Documents & Publications 300ºC DDS + 300ºC MWD Development of a HT Seismic Tool track 3: enhanced geothermal systems (EGS) | geothermal 2015 peer review

  4. FEMP'S O&M Best Practices Guide A Guide to Achieving Operational...

    Office of Scientific and Technical Information (OSTI)

    Efficiency The Federal Energy Management Program's (FEMP's) O&M Best Practices ... under the direction of the Department of Energy's Federal Energy Management Program. ...

  5. O&M Best Practices - A Guide to Achieving Operational Efficiency...

    Office of Scientific and Technical Information (OSTI)

    This guide, sponsored by DOE's Federal Energy Management Program, highlights operations ... about O&M management, technologies, energy efficiency and cost-reduction approaches. ...

  6. Photo of the Week: RoHAWKtics at Oak Ridge National Laboratory | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Energy RoHAWKtics at Oak Ridge National Laboratory Photo of the Week: RoHAWKtics at Oak Ridge National Laboratory April 1, 2013 - 3:40pm Addthis Tennessee Governor Bill Haslam signs the robot of Hardin Valley Academy's FIRST robotics team during the dedication of DOE's Carbon Fiber Technology Facility, located at Oak Ridge National Laboratory. The RoHAWKtics team (named after their school mascot) spent an intense six weeks constructing the robot, using design, engineering, and

  7. CNS-sponsored RoHAWKtics competes at world's largest robotics competition

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    | Y-12 National Security Complex RoHAWKtics ... CNS-sponsored RoHAWKtics competes at world's largest robotics competition Posted: July 7, 2016 - 9:10am The RoHAWKtics robotics team at Hardin Valley Academy, sponsored by Consolidated Nuclear Security, LLC, achieved a top 50 ranking at the FIRST® Robotics Championship in St. Louis. Despite a broken bolt, a flat tire and countless other issues, the robotics team at Hardin Valley Academy, sponsored by Consolidated Nuclear Security, LLC,

  8. PRE-DISCOVERY OBSERVATIONS OF CoRoT-1b AND CoRoT-2b WITH THE BEST SURVEY

    SciTech Connect (OSTI)

    Rauer, H.; Erikson, A.; Kabath, P.; Hedelt, P.; Csizmadia, Sz.; Paris, P. v.; Renner, S.; Titz, R.; Voss, H.; Boer, M.; Tournois, G.; Carone, L.; Eigmueller, P.

    2010-01-15

    The Berlin Exoplanet Search Telescope (BEST) wide-angle telescope installed at the Observatoire de Haute-Provence and operated in remote control from Berlin by the Institut fuer Planetenforschung, DLR, has observed the CoRoT target fields prior to the mission. The resulting archive of stellar photometric light curves is used to search for deep transit events announced during CoRoT's alarm mode to aid in fast photometric confirmation of these events. The 'initial run' field of CoRoT (IRa01) was observed with BEST in 2006 November and December for 12 nights. The first 'long run' field (LRc01) was observed from 2005 June to September for 35 nights. After standard CCD data reduction, aperture photometry has been performed using the ISIS image subtraction method. About 30,000 light curves were obtained in each field. Transits of the first detected planets by the CoRoT mission, CoRoT-1b and CoRoT-2b, were found in archived data of the BEST survey and their light curves are presented here. Such detections provide useful information at the early stage of the organization of follow-up observations of satellite alarm-mode planet candidates. In addition, no period change was found over {approx}4 years between the first BEST observation and last available transit observations.

  9. A Best Practice for Developing Availability Guarantee Language in Photovoltaic (PV) O&M Agreements.

    SciTech Connect (OSTI)

    Klise, Geoffrey Taylor; Balfour, John

    2015-11-01

    This document outlines the foundation for developing language that can be utilized in an Equipment Availability Guarantee, typically included in an O&M services agreement between a PV system or plant owner and an O&M services provider, or operator. Many of the current PV O&M service agreement Availability Guarantees are based on contracts used for traditional power generation, which create challenges for owners and operators due to the variable nature of grid-tied photovoltaic generating technologies. This report documents language used in early PV availability guarantees and presents best practices and equations that can be used to more openly communicate how the reliability of the PV system and plant equipment can be expressed in an availability guarantee. This work will improve the bankability of PV systems by providing greater transparency into the equipment reliability state to all parties involved in an O&M services contract.

  10. Where might I find simplified Data on Capital, O&M, and fuel...

    Open Energy Info (EERE)

    Where might I find simplified Data on Capital, O&M, and fuel costs? Home I teach math to high school seniors. My students are studying energy in all their classes. I have just...

  11. Remediation of Mercury and Industrial Contaminants Applied Field Research Initiative (RoMIC-AFRI)

    Broader source: Energy.gov [DOE]

    Located on the Oak Ridge Reservation (ORR) in Oak Ridge, Tennessee, the RoMIC-AFRI was established to protect water resources by addressing the challenge of preventing contamination. The initiative...

  12. Significant issues and changes for ANSI/ASME OM-1 1981, part 1, ASME OMc code-1994, and ASME OM Code-1995, Appendix I, inservice testing of pressure relief devices in light water reactor power plants

    SciTech Connect (OSTI)

    Seniuk, P.J.

    1996-12-01

    This paper identifies significant changes to the ANSI/ASME OM-1 1981, Part 1, and ASME Omc Code-1994 and ASME OM Code-1995, Appendix I, {open_quotes}Inservice Testing of Pressure Relief Devices in Light-Water Reactor Power Plants{close_quotes}. The paper describes changes to different Code editions and presents insights into the direction of the code committee and selected topics to be considered by the ASME O&M Working Group on pressure relief devices. These topics include scope issues, thermal relief valve issues, as-found and as-left set-pressure determinations, exclusions from testing, and cold setpoint bench testing. The purpose of this paper is to describe some significant issues being addressed by the O&M Working Group on Pressure Relief Devices (OM-1). The writer is currently the chair of OM-1 and the statements expressed herein represents his personal opinion.

  13. O/M RATIO MEASUREMENT IN PURE AND MIXED OXIDE FULES - WHERE ARE WE NOW?

    SciTech Connect (OSTI)

    J. RUBIN; ET AL

    2000-12-01

    The oxygen-to-metal (O/M) ratio is one of the most critical parameters of nuclear fuel fabrication, and its measurement is closely monitored for manufacturing process control and to ensure the service behavior of the final product. Thermogravimetry is the most widely used method, the procedure for which has remained largely unchanged since its development some thirty years ago. It was not clear to us, however, that this method is still the optimum one in light of advances in instrumentation, and in the current regulatory environment, particularly with regard to waste management and disposal. As part of the MOX fuel fabrication program at Los Alamos, we conducted a comprehensive review of methods for O/M measurements in UO{sub 2}, PuO{sub 2} and mixed oxide fuels for thermal reactors. A concerted effort was made to access information not available in the open literature. We identified approximately thirty five experimental methods that (a) have been developed with the intent of measuring O/M, (b) provided O/M indirectly by suitable reduction of the measured data, or (c) could provide O/M data with suitable data reduction or when combined with other methods. We will discuss the relative strengths and weaknesses of these methods in their application to current routine and small-lot production environment.

  14. Changes of O/M, dimension and microstructure of MOX pellet during heat treatment

    SciTech Connect (OSTI)

    Watanabe, M.; Kato, M.; Sunaoshi, T.

    2013-07-01

    The oxidation and reduction behaviors of sintered (Pu{sub 0.3}U{sub 0.7})O{sub 2-x} pellets have been studied at 1873 K under a controlled oxygen partial pressure. From the results of oxygen-to-metal (O/M) ratio changes, dimensional and structural changes, it was concluded that the crack nucleation-propagation and the local density change of pores were caused by the tensile and compressive stresses due to the O/M ratio distribution in the direction of the pellet radius. (authors)

  15. Top Operations and Maintenance (O&M) Efficiency Opportunities at DoD/Army Sites - A Guide for O&M/Energy Managers and Practitioners

    SciTech Connect (OSTI)

    Sullivan, Gregory P.; Dean, Jesse D.; Dixon, Douglas R.

    2007-05-25

    This report, sponsored the Army's Energy Engineering Analysis Program, provides the Operations and Maintenance (O&M) Energy manager and practitioner with useful information about the top O&M opportunities consistently found across the DoD/Army sector. The target is to help the DoD/Army sector develop a well-structured and organized O&M program.

  16. THE FUTURE OF THE SUN: AN EVOLVED SOLAR TWIN REVEALED BY CoRoT

    SciTech Connect (OSTI)

    Do Nascimento, J.-D. Jr.; Da Costa, J. S.; Castro, M.; Takeda, Y.; Melendez, J.

    2013-07-10

    The question of whether the Sun is peculiar within the class of solar-type stars has been the subject of active investigation over the past three decades. Although several solar twins have been found with stellar parameters similar to those of the Sun (albeit in a range of Li abundances and with somewhat different compositions), their rotation periods are unknown, except for 18 Sco, which is younger than the Sun and with a rotation period shorter than solar. It is difficult to obtain rotation periods for stars of solar age from ground-based observations, as a low-activity level implies a shallow rotational modulation of their light curves. CoRoT has provided space-based long time series from which the rotation periods of solar twins as old as the Sun could be estimated. Based on high-signal-to-noise, high-resolution spectroscopic observations gathered at the Subaru Telescope, we show that the star CoRoT ID 102684698 is a somewhat evolved solar twin with a low Li abundance. Its rotation period is 29 {+-} 5 days, compatible with its age (6.7 Gyr) and low lithium content, A{sub Li} {approx}< 0.85 dex. Interestingly, our CoRoT solar twin seems to have enhanced abundances of the refractory elements with respect to the Sun, a typical characteristic of most nearby twins. With a magnitude V {approx_equal} 14.1, ID 102684698 is the first solar twin revealed by CoRoT, the farthest field solar twin so far known, and the only solar twin older than the Sun for which a rotation period has been determined.

  17. STANDING ORDER 1. Standing Order Number: EP-DIV-S0-20222, R.O

    Office of Environmental Management (EM)

    CC;K CLEAR FORM

    STANDING ORDER 1. Standing Order Number: EP-DIV-S0-20222, R.O 2. Standing Order Type: (check one) [8J Division D Facility 3. Applicable Facilities: All EWMO Facilities 4. Standing Order Title: EWMO Legacy TRU Waste Pause 5. Distribution List: (By Functional Title) TA-54 Timely Order Book, Waste Characterization, Reduction, and Repackaging Facility (WCRRF) Timely Order Book, Radioassay and Nondestructive Testing (RANT) Facility Timely Order Book, and Environmental Programs

  18. THE CoRoT DISCOVERY OF A UNIQUE TRIPLE-MODE CEPHEID IN THE GALAXY

    SciTech Connect (OSTI)

    Poretti, E.; Baglin, A.; Weiss, W. W.

    2014-11-10

    The exploitation of the CoRoT treasure of stars observed in the exoplanetary field allowed the detection of a unusual triple-mode Cepheid in the Milky Way, CoRoT 0223989566. The two modes with the largest amplitudes and a period ratio of 0.80 are identified with the first (P {sub 1} = 1.29 days) and second (P {sub 2} = 1.03 days) radial overtones. The third period, which has the smallest amplitude but is able to produce combination terms with the other two, is the longest one (P {sub 3} = 1.89 days). The ratio of 0.68 between the first-overtone period and the third period is the unusual feature. Its identification with the fundamental radial or a nonradial mode is discussed with respect to similar cases in the Magellanic Clouds. In both cases, the period triplet and the respective ratios make the star unique in our Galaxy. The distance derived from the period-luminosity relation and the galactic coordinates put CoRoT 0223989566 in the metal-rich environment of the ''outer arm'' of the Milky Way.

  19. Tools_Equipment under 10K RO 23_120213.xlsx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Other Government Furnished Property (GFP) / Equipment 1 RO BARCODE DESCRIPTION MANUF. MODEL SN COST BLDG ROOM INVT_DATE 23 0000032497 THERMAL LABELING SYS BRADY WORLDWIDE TLS2200 BPTLS901644924 $0.00 28 119 24-Sep-13 23 F13412 PWR SUPPLY & READ BR BROOKS 5878 881OHC025872 $0.00 94 01 24-Sep-13 23 0000032498 THERMAL LABELING SYS BRADY WORLDWIDE TLS2200 BPTLS902745018 $0.00 17 106 24-Sep-13 23 0000106857 RECIRCULATOR POLYSCI POLY SCIENCE N0691883 G52197 $0.00 83 242 4-Oct-13 23 0000021812

  20. Ab initio ro-vibronic spectroscopy of SiCCl (X{sup ~2}Π)

    SciTech Connect (OSTI)

    Brites, Vincent; Mitrushchenkov, Alexander O.; Léonard, Céline; Peterson, Kirk A.

    2014-07-21

    The full dimensional potential energy surfaces of the {sup 2}A{sup ′} and {sup 2}A{sup ′′} electronic components of X{sup ~2}Π SiCCl have been computed using the explicitly correlated coupled cluster method, UCCSD(T)-F12b, combined with a composite approach taking into account basis set incompleteness, core-valence correlation, scalar relativity, and higher order excitations. The spin-orbit and dipole moment surfaces have also been computed ab initio. The ro-vibronic energy levels and absorption spectrum at 5 K have been determined from variational calculations. The influence of each correction on the fundamental frequencies is discussed. An assignment is proposed for bands observed in the LIF experiment of Smith et al. [J. Chem. Phys. 117, 6446 (2002)]. The overall agreement between the experimental and calculated ro-vibronic levels is better than 7 cm{sup −1} which is comparable with the 10–20 cm{sup −1} resolution of the emission spectrum.

  1. A hybrid ED/RO process for TDS reduction of produced waters

    SciTech Connect (OSTI)

    Tsai, S.P.; Datta, R.; Frank, J.R.

    1995-12-31

    Large volumes of produced waters are generated from natural gas production. In the United States the prevailing management practice for produced waters is deep well injection, but this practice is costly. Therefore minimizing the need for deep well injection is desirable. A major treatment issue for produced waters is the reduction of total dissolved solids (TDS), which consist mostly of inorganic salts. A hybrid electrodialysis/reverse-osmosis (ED/RO) treatment process is being developed to concentrate the salts in produced waters and thereby reduce the volume of brine that needs to be managed for disposal. The desalted water can be used beneficially or discharged. In this study, laboratory feasibility experiments were conducted by using produced waters from multiple sites. A novel-membrane configuration approach to prevent fouling and scale formation was developed and demonstrated. Results of laboratory experiments and plans for field demonstration are discussed.

  2. DEPXRTMEKT OF ENV]RO~:MENTAL F'ROTECTION DlVklOh OF

    Office of Legacy Management (LM)

    . * @.+<, .-- v 7, -e -5 u i' ;. - - : ,.:,, 4-.1M-4. a". : ' - l-1 &dp d 3-m 3jPr5Py DEPXRTMEKT OF ENV]RO~:MENTAL F'ROTECTION DlVklOh OF ~NVIR0N~Eh~A.L OUR' tiIn - . BUREAU OF R&DllmcN t=ROTE~lOH ' 1 ,_ jBD 5cOTCH ROAD. ~R~%~obi. fd. 1. 08628 .' - ._ -_ _ . . : S=_srterrjer 27, 1977 - ,. _ :.- ,_..I \ L . x=- a-. JEC): f' eust C--l L-9 ,c:c- -*r 2ze E&f&y _3=iz=Et=g cr;i\' ==Siq ' ---res"LE;, c2iiIps - de- ~-z7~~to3, Bew --d Jersey DE540 3ez' -- . w- Tecsk: i 25,

  3. Code cases for implementing risk-based inservice testing in the ASME OM code

    SciTech Connect (OSTI)

    Rowley, C.W.

    1996-12-01

    Historically inservice testing has been reasonably effective, but quite costly. Recent applications of plant PRAs to the scope of the IST program have demonstrated that of the 30 pumps and 500 valves in the typical plant IST program, less than half of the pumps and ten percent of the valves are risk significant. The way the ASME plans to tackle this overly-conservative scope for IST components is to use the PRA and plant expert panels to create a two tier IST component categorization scheme. The PRA provides the quantitative risk information and the plant expert panel blends the quantitative and deterministic information to place the IST component into one of two categories: More Safety Significant Component (MSSC) or Less Safety Significant Component (LSSC). With all the pumps and valves in the IST program placed in MSSC or LSSC categories, two different testing strategies will be applied. The testing strategies will be unique for the type of component, such as centrifugal pump, positive displacement pump, MOV, AOV, SOV, SRV, PORV, HOV, CV, and MV. A series of OM Code Cases are being developed to capture this process for a plant to use. One Code Case will be for Component Importance Ranking. The remaining Code Cases will develop the MSSC and LSSC testing strategy for type of component. These Code Cases are planned for publication in early 1997. Later, after some industry application of the Code Cases, the alternative Code Case requirements will gravitate to the ASME OM Code as appendices.

  4. ON THE ASYMMETRY OF THE OH RO-VIBRATIONAL LINES IN HD 100546

    SciTech Connect (OSTI)

    Fedele, D.; Bruderer, S.; Van den Ancker, M. E.; Pascucci, I. E-mail: mvandena@eso.org

    2015-02-10

    We present multi-epoch high-spectral resolution observations with VLT/CRIRES of the OH doublet {sup 2}Π{sub 3/2} P4.5 (1+, 1–) (2.934 μm) toward the protoplanetary disk around HD 100546. The OH doublet is detected at all epochs and is spectrally resolved while nearby H{sub 2}O lines remain undetected. The OH line velocity profile is different in the three data sets: in the first epoch (2012 April, P.A. = 26°) the OH lines are symmetric and line broadening is consistent with the gas being in Keplerian rotation around the star. No OH emission is detected within a radius of 8-11 AU from the star: the line emitting region is similar in size and extent to that of the CO ro-vibrational lines. In the other two epochs (2013 March and 2014 April, P.A. = 90° and 10°, respectively) the OH lines appear asymmetric and fainter compared to 2012 April. We investigate the origin of these line asymmetries which were taken by previous authors as evidence for tidal interaction between a (unseen) massive planet and the disk. We show that the observed asymmetries can be fully explained by a misalignment of the slit of the order of 0.''04-0.''20 with respect to the stellar position. The disk is spatially resolved and the slit misalignment is likely caused by the extended dust emission which is brighter than the stellar photosphere at near-infrared wavelengths which is the wavelength used for the pointing. This can cause the photo-center of HD 100546 to be misaligned with the stellar position at near-infrared wavelengths.

  5. A 0.8-2.4 ?m Transmission spectrum of the hot Jupiter CoRoT-1b

    SciTech Connect (OSTI)

    Schlawin, E.; Herter, T.; Zhao, M.; Teske, J. K.

    2014-03-01

    Hot Jupiters with brightness temperatures ?2000 K can have TiO and VO molecules as gaseous species in their atmospheres. The TiO and VO molecules can potentially induce temperature inversions in hot Jupiter atmospheres and also have an observable signature of large optical to infrared transit depth ratios. Previous transmission spectra of very hot Jupiters have shown a lack of TiO and VO, but only in planets that also appear to lack temperature inversions. We measure the transmission spectrum of CoRoT-1b, a hot Jupiter that was predicted to have a temperature inversion potentially due to significant TiO and VO in its atmosphere. We employ the multi-object spectroscopy method using the SpeX and MORIS instruments on the Infrared Telescope Facility (IRTF) and the Gaussian process method to model red noise. By using a simultaneous reference star on the slit for calibration and a wide slit to minimize slit losses, we achieve transit depth precision of 0.03%-0.09%, comparable to the atmospheric scale height but detect no statistically significant molecular features. We combine our IRTF data with optical CoRoT transmission measurements to search for differences in the optical and near-infrared absorption that would arise from TiO/VO. Our IRTF spectrum and the CoRoT photometry disfavor a TiO/VO-rich spectrum for CoRoT-1b, suggesting that the atmosphere has another absorber that could create a temperature inversion or that the blackbody-like emission from the planet is due to a spectroscopically flat cloud, dust, or haze layer that smoothes out molecular features in both CoRoT-1b's emission and transmission spectra. This system represents the faintest planet hosting star (K = 12.2) with a measured planetary transmission spectrum.

  6. Modeling and simulation of offshore wind farm O&M processes

    SciTech Connect (OSTI)

    Joschko, Philip; Widok, Andi H.; Appel, Susanne; Greiner, Saskia; Albers, Henning; Page, Bernd

    2015-04-15

    This paper describes a holistic approach to operation and maintenance (O&M) processes in the domain of offshore wind farm power generation. The acquisition and process visualization is followed by a risk analysis of all relevant processes. Hereafter, a tool was designed, which is able to model the defined processes in a BPMN 2.0 notation, as well as connect and simulate them. Furthermore, the notation was enriched with new elements, representing other relevant factors that were, to date, only displayable with much higher effort. In that regard a variety of more complex situations were integrated, such as for example new process interactions depending on different weather influences, in which case a stochastic weather generator was combined with the business simulation or other wind farm aspects important to the smooth running of the offshore wind farms. In addition, the choices for different methodologies, such as the simulation framework or the business process notation will be presented and elaborated depending on the impact they had on the development of the approach and the software solution. - Highlights: • Analysis of operation and maintenance processes of offshore wind farms • Process modeling with BPMN 2.0 • Domain-specific simulation tool.

  7. The intrinsic and interactive effects of RO 15-4513 and ethanol on locomotor activity, body temperature, and blood glucose concentration

    SciTech Connect (OSTI)

    Wood, A.L.; Healey, P.A.; Menendez, J.A.; Verne, S.L.; Atrens, D.M. )

    1989-01-01

    The ability of the putative ethanol antagonist RO 15-4513 to antagonize ethanol-induced hypoactivity, hypothermia and hyperglycemia was investigated in rats. Although RO 15-4513 produced hypoactivity by itself, it attenuated ethanol-induced hypoactivity. This antagonism suggests that ethanol-induced hypoactivity is mediated by the GABA-benzodiazepine receptor complex which is thought to be the site of action of RO 15-4513. In contrast, although RO 15-4513 produced hypothermia by itself, it had no significant effect on ethanol-induced hypothermia. This suggests that the hypothermic effect of ethanol is not mediated by the GABA-benzodiazepine receptor complex. The fact that RO 15-4513, ethanol and the vehicle all produced hyperglycemia suggests a common stress effect and does not permit any firm conclusions to be drawn as to the interaction between ethanol and RO 15-4513 in modulating glycemic responses. These data indicate that the ethanol antagonism of RO 15-4513 is primarily confined to ethanol's behavioral effects and that ethanol's behavioral and physiological effects are mediated by neurochemically distinct mechanisms.

  8. The new Mercedes-Benz OM 904 LA light heavy-duty diesel engine for class 6 trucks

    SciTech Connect (OSTI)

    Schittler, M.; Bergmann, H.; Flathmann, K.

    1996-09-01

    As part of a comprehensive strategic product initiative the most important commercial vehicle manufacturer--Mercedes-Benz AG--is step by step renewing its entire product range. This primarily refers to the heart of the vehicles--the engine. After the OM 457 LA, which was developed together with DDC for the special American market demands and which is produced and sold in the US by DDC under the label Series 55, has had its premiere in Freightliner`s Century Class, the OM 904 LA will now follow in the light commercial vehicle class. This engine has a completely new concept of a direct-injection, highly sophisticated turbocharged four-cylinder in-line engine with air-to-air intercooler, whose main characteristics can be outlined by the terms multi-valve technology, high-pressure injection via unit pumps and electronic engine control. This small engine has several interesting features, which--up to now--were only known from class 8 engines. In addition to fulfilling increased customer demands with regard to long service life, easy maintenance, reliability and economy, great attention was paid during the design of the engine to not only fulfill the global regulations, but also account for sufficient potential to comply with further aggravations to be expected. The most important design features and the attained engine ratings are indicated and explained in detail.

  9. Correlation testing of the European EMA (Engine Manufacturers Association) round-robin engine (Daimler-Benz OM 366a). Heavy-duty engine testing report. Technical report

    SciTech Connect (OSTI)

    Baines, T.M.

    1987-12-01

    This report examines the results of testing the Daimler-Benz OM 366 A heavy-duty engine at the Environmental Protection Agency Motor Vehicle Emission Laboratory. This heavy-duty engine was tested for the purpose of providing correlation data for the comparison with similar data developed by European Engine Manufacturers (EMA). The European EMA members organized a round robin testing program and decided to test a Daimler-Benz OM 366A engine, and to focus the program on gathering simple cold start/hot start Federal Test Procedure data. The report includes the results of the tests, including engine description, fuels, test procedures and test plans.

  10. Knuteson-RO

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    role of the U.S. Depart- ment of Energy's (DOE) Advanced Vehicle Testing Activity (AVTA) is to bridge the gap between R&D and commercial availability of advanced vehicle technologies. AVTA supports DOE's FreedomCAR and Vehicle Technologies Program in moving these technologies from R&D to market deployment by examining market factors and customer requirements, evaluating performance and durability of alternative fuel and advanced technology vehicles, and assessing the performance of these

  11. IMPROVED VARIABLE STAR SEARCH IN LARGE PHOTOMETRIC DATA SETS: NEW VARIABLES IN CoRoT FIELD LRa02 DETECTED BY BEST II

    SciTech Connect (OSTI)

    Fruth, T.; Cabrera, J.; Csizmadia, Sz.; Eigmueller, P.; Erikson, A.; Kirste, S.; Pasternacki, T.; Rauer, H.; Titz-Weider, R.; Kabath, P.; Chini, R.; Lemke, R.; Murphy, M.

    2012-06-15

    The CoRoT field LRa02 has been observed with the Berlin Exoplanet Search Telescope II (BEST II) during the southern summer 2007/2008. A first analysis of stellar variability led to the publication of 345 newly discovered variable stars. Now, a deeper analysis of this data set was used to optimize the variability search procedure. Several methods and parameters have been tested in order to improve the selection process compared to the widely used J index for variability ranking. This paper describes an empirical approach to treat systematic trends in photometric data based upon the analysis of variance statistics that can significantly decrease the rate of false detections. Finally, the process of reanalysis and method improvement has virtually doubled the number of variable stars compared to the first analysis by Kabath et al. A supplementary catalog of 272 previously unknown periodic variables plus 52 stars with suspected variability is presented. Improved ephemerides are given for 19 known variables in the field. In addition, the BEST II results are compared with CoRoT data and its automatic variability classification.

  12. Communication: Ro-vibrational control of chemical reactivity in H+CH{sub 4}→ H{sub 2}+CH{sub 3} : Full-dimensional quantum dynamics calculations and a sudden model

    SciTech Connect (OSTI)

    Welsch, Ralph Manthe, Uwe

    2014-08-07

    The mode-selective chemistry of the title reaction is studied by full-dimensional quantum dynamics simulation on an accurate ab initio potential energy surface for vanishing total angular momentum. Using a rigorous transition state based approach and multi-configurational time-dependent Hartree wave packet propagation, initial state-selected reaction probabilities for many ro-vibrational states of methane are calculated. The theoretical results are compared with experimental trends seen in reactions of methane. An intuitive interpretation of the ro-vibrational control of the chemical reactivity provided by a sudden model based on the quantum transition state concept is discussed.

  13. Speciated measurements of semivolatile and intermediate volatility organic compounds (S/IVOCs) in a pine forest during BEACHON-RoMBAS 2011

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Chan, A. W. H.; Kreisberg, N. M.; Hohaus, T.; Campuzano-Jost, P.; Zhao, Y.; Day, D. A.; Kaser, L.; Karl, T.; Hansel, A.; Teng, A. P.; et al

    2016-02-02

    Understanding organic composition of gases and particles is essential to identifying sources and atmospheric processing leading to organic aerosols (OA), but atmospheric chemical complexity and the analytical techniques available often limit such analysis. Here we present speciated measurements of semivolatile and intermediate volatility organic compounds (S/IVOCs) using a novel dual-use instrument (SV-TAG-AMS) deployed at Manitou Forest, CO, during the Bio-hydro-atmosphere interactions of Energy, Aerosols, Carbon, H2O, Organics & Nitrogen – Rocky Mountain Biogenic Aerosol Study (BEACHON-RoMBAS) 2011 campaign. This instrument provides on-line speciation of ambient organic compounds with 2 h time resolution. The species in this volatility range are complexmore » in composition, but their chemical identities reveal potential sources. Observed compounds of biogenic origin include sesquiterpenes with molecular formula C15H24 (e.g., β-caryophyllene and longifolene), which were most abundant at night. A variety of other biogenic compounds were observed, including sesquiterpenoids with molecular formula C15H22, abietatriene and other terpenoid compounds. Many of these compounds have been identified in essential oils and branch enclosure studies but were observed in ambient air for the first time in our study. Semivolatile polycyclic aromatic hydrocarbons (PAHs) and alkanes were observed with highest concentrations during the day and the dependence on temperature suggests the role of an evaporative source. Using statistical analysis by positive matrix factorization (PMF), we classify observed S/IVOCs by their likely sources and processes, and characterize them based on chemical composition. The total mass concentration of elutable S/IVOCs was estimated to be on the order of 0.7 µg m–3 and their volatility distributions are estimated for modeling aerosol formation chemistry.« less

  14. Structural health and prognostics management for offshore wind turbines : case studies of rotor fault and blade damage with initial O&M cost modeling.

    SciTech Connect (OSTI)

    Myrent, Noah J.; Kusnick, Joshua F.; Barrett, Natalie C.; Adams, Douglas E.; Griffith, Daniel Todd

    2013-04-01

    Operations and maintenance costs for offshore wind plants are significantly higher than the current costs for land-based (onshore) wind plants. One way to reduce these costs would be to implement a structural health and prognostic management (SHPM) system as part of a condition based maintenance paradigm with smart load management and utilize a state-based cost model to assess the economics associated with use of the SHPM system. To facilitate the development of such a system a multi-scale modeling approach developed in prior work is used to identify how the underlying physics of the system are affected by the presence of damage and faults, and how these changes manifest themselves in the operational response of a full turbine. This methodology was used to investigate two case studies: (1) the effects of rotor imbalance due to pitch error (aerodynamic imbalance) and mass imbalance and (2) disbond of the shear web; both on a 5-MW offshore wind turbine in the present report. Based on simulations of damage in the turbine model, the operational measurements that demonstrated the highest sensitivity to the damage/faults were the blade tip accelerations and local pitching moments for both imbalance and shear web disbond. The initial cost model provided a great deal of insight into the estimated savings in operations and maintenance costs due to the implementation of an effective SHPM system. The integration of the health monitoring information and O&M cost versus damage/fault severity information provides the initial steps to identify processes to reduce operations and maintenance costs for an offshore wind farm while increasing turbine availability, revenue, and overall profit.

  15. OSTIblog Articles in the FR Topic | OSTI, US Dept of Energy Office of

    Office of Scientific and Technical Information (OSTI)

    Scientific and Technical Information FR

  16. Accountable Property RO23_120213.xlsx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... PXI-1042 VOX424AA 16,177.31 B04 210 24-Sep-13 23 0000001354 AUTOSAMPLER SYSTEM ( ESI APEX FAST APEXFST080608 16,285.00 83 242 4-Oct-13 23 0000001639 AUTOSAMPLER SYSTEM P PERKIN ...

  17. Sensitive Property RO 23_120213.xlsx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... PACKARD ENVY PRO B-000 CND2270FXG 781.00 T1 C14 20-Sep-13 23 S11616 VIDEO SET, 1999 NEC NFPA NEC EXPERT SERIES NA 796.00 59 5 4-Oct-13 23 0000040180 COMPUTER, DESKTOP CO ...

  18. Ingenieurb ro Henning Holst | Open Energy Information

    Open Energy Info (EERE)

    search Name: Ingenieurbro Henning Holst Place: Husum, Germany Zip: 25813 Sector: Wind energy Product: Wind energy consultant and project developer. References:...

  19. Microsoft Word - knuteson-ro.doc

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... The number of AERI observations used in the monthly statistics is shown in Figure 4 as a ... The opposite is true for the monthly statistics of the 10 m observed brightness ...

  20. Notice of Final Determination, Federal Register, 71 FR 47791...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Final Determination, Federal Register, 71 FR 47791, August 18, 2006 Notice of Final Determination, Federal Register, 71 FR 47791, August 18, 2006 Document displays the notice of ...

  1. Proposed Rule Correction, Federal Register, 75 FR 66008, October...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Proposed Rule Correction, Federal Register, 75 FR 66008, October 27, 2010 Proposed Rule Correction, Federal Register, 75 FR 66008, October 27, 2010 Document displays a correction ...

  2. CSI 2264: simultaneous optical and infrared light curves of young disk-bearing stars in NGC 2264 with CoRoT and Spitzerevidence for multiple origins of variability

    SciTech Connect (OSTI)

    Cody, Ann Marie; Stauffer, John; Rebull, Luisa M.; Carey, Sean; Baglin, Annie; Micela, Giuseppina; Flaccomio, Ettore; Morales-Caldern, Mara; Aigrain, Suzanne; Bouvier, Jrme; Gutermuth, Robert; Song, Inseok; Turner, Neal; Alencar, Silvia H. P.; Zwintz, Konstanze; Plavchan, Peter; Terebey, Susan; and others

    2014-04-01

    We present the Coordinated Synoptic Investigation of NGC 2264, a continuous 30 day multi-wavelength photometric monitoring campaign on more than 1000 young cluster members using 16 telescopes. The unprecedented combination of multi-wavelength, high-precision, high-cadence, and long-duration data opens a new window into the time domain behavior of young stellar objects. Here we provide an overview of the observations, focusing on results from Spitzer and CoRoT. The highlight of this work is detailed analysis of 162 classical T Tauri stars for which we can probe optical and mid-infrared flux variations to 1% amplitudes and sub-hour timescales. We present a morphological variability census and then use metrics of periodicity, stochasticity, and symmetry to statistically separate the light curves into seven distinct classes, which we suggest represent different physical processes and geometric effects. We provide distributions of the characteristic timescales and amplitudes and assess the fractional representation within each class. The largest category (>20%) are optical 'dippers' with discrete fading events lasting ?1-5 days. The degree of correlation between the optical and infrared light curves is positive but weak; notably, the independently assigned optical and infrared morphology classes tend to be different for the same object. Assessment of flux variation behavior with respect to (circum)stellar properties reveals correlations of variability parameters with H? emission and with effective temperature. Overall, our results point to multiple origins of young star variability, including circumstellar obscuration events, hot spots on the star and/or disk, accretion bursts, and rapid structural changes in the inner disk.

  3. Ks-BAND DETECTION OF THERMAL EMISSION AND COLOR CONSTRAINTS TO CoRoT-1b: A LOW-ALBEDO PLANET WITH INEFFICIENT ATMOSPHERIC ENERGY REDISTRIBUTION AND A TEMPERATURE INVERSION

    SciTech Connect (OSTI)

    Rogers, Justin C.; Apai, Daniel; Lopez-Morales, Mercedes; Sing, David K.; Burrows, Adam

    2009-12-20

    We report the detection in Ks-band of the secondary eclipse of the hot Jupiter CoRoT-1b from time series photometry with the ARC 3.5 m telescope at Apache Point Observatory. The eclipse shows a depth of 0.336 +- 0.042% and is centered at phase 0.5022{sup +0.0023}{sub -0.0027}, consistent with a zero eccentricity orbit (e cos omega = 0.0035{sup +0.0036}{sub -0.0042}). We perform the first optical to near-infrared multi-band photometric analysis of an exoplanet's atmosphere and constrain the reflected and thermal emissions by combining our result with the recent 0.6, 0.71, and 2.09 mum secondary eclipse detections by Snellen et al., Gillon et al., and Alonso et al. Comparing the multi-wavelength detections to state-of-the-art radiative-convective chemical-equilibrium atmosphere models, we find the near-infrared fluxes difficult to reproduce. The closest blackbody-based and physical models provide the following atmosphere parameters: a temperature T = 2460{sup +80}{sub -160} K; a very low Bond albedo A{sub B} = 0.000{sup +0.081}{sub -0.000}; and an energy redistribution parameter P{sub n} = 0.1, indicating a small but nonzero amount of heat transfer from the day to nightside. The best physical model suggests a thermal inversion layer with an extra optical absorber of opacity kappa{sub e} = 0.05 cm{sup 2} g{sup -1}, placed near the 0.1 bar atmospheric pressure level. This inversion layer is located 10 times deeper in the atmosphere than the absorbers used in models to fit mid-infrared Spitzer detections of other irradiated hot Jupiters.

  4. Exploring atmospheres of hot mini-Neptune and extrasolar giant planets orbiting different stars with application to HD 97658b, WASP-12b, CoRoT-2b, XO-1b, and HD 189733b

    SciTech Connect (OSTI)

    Miguel, Y.; Kaltenegger, L.

    2014-01-10

    We calculated an atmospheric grid for hot mini-Neptune and giant exoplanets that links astrophysical observable parametersorbital distance and stellar typewith the chemical atmospheric species expected. The grid can be applied to current and future observations to characterize exoplanet atmospheres and serves as a reference to interpret atmospheric retrieval analysis results. To build the grid, we developed a one-dimensional code for calculating the atmospheric thermal structure and linked it to a photochemical model that includes disequilibrium chemistry (molecular diffusion, vertical mixing, and photochemistry). We compare the thermal profiles and atmospheric composition of planets at different semimajor axes (0.01 AU ? a ? 0.1 AU) orbiting F, G, K, and M stars. Temperature and UV flux affect chemical species in the atmosphere. We explore which effects are due to temperature and which are due to stellar characteristics, showing the species most affected in each case. CH{sub 4} and H{sub 2}O are the most sensitive to UV flux, H displaces H{sub 2} as the most abundant gas in the upper atmosphere for planets receiving a high UV flux. CH{sub 4} is more abundant for cooler planets. We explore vertical mixing, to inform degeneracies on our models and in the resulting spectral observables. For lower pressures, observable species like H{sub 2}O or CO{sub 2} can indicate the efficiency of vertical mixing, with larger mixing ratios for a stronger mixing. By establishing the grid, testing the sensitivity of the results, and comparing our model to published results, our paper provides a tool to estimate what observations could yield. We apply our model to WASP-12b, CoRoT-2b, XO-1b, HD189733b, and HD97658b.

  5. CRAD, NNSA- Facility Representatives (FR)

    Office of Energy Efficiency and Renewable Energy (EERE)

    CRAD for Facility Representatives (FR). Criteria Review and Approach Documents (CRADs) that can be used to conduct a well-organized and thorough assessment of elements of safety and health programs.

  6. Om Power Corporation Ltd | Open Energy Information

    Open Energy Info (EERE)

    Ltd. Place: Palampur, Himachal Pradesh, India Sector: Hydro Product: Palampur-based small hydro project developer. Coordinates: 32.110378, 76.535988 Show Map Loading...

  7. FR Frankensolar GmbH | Open Energy Information

    Open Energy Info (EERE)

    search Name: FR Frankensolar GmbH Place: Nrnberg, Germany Zip: 90431 Product: German PV modules distributor. References: FR Frankensolar GmbH1 This article is a stub....

  8. Notice of Availability, Federal Register, 75 FR 78231, December...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    75 FR 78231, December 15, 2010 Notice of Availability, Federal Register, 75 FR 78231, December 15, 2010 Notice of availability for the Management of Energy and Water Efficiency in...

  9. Final Technical Report: Mercury Release from Organic Matter (OM) and OM-Coated Mineral Surfaces

    SciTech Connect (OSTI)

    Nagy, Kathryn L.

    2015-08-18

    Chemical reactions between mercury, a neurotoxin, and sulfur, an essential nutrient, in the environment control to a large extent the distribution and amount of mercury available for uptake by living organisms. The largest reservoir of sulfur in soils is in living, decaying, and dissolved natural organic matter. The decaying and dissolved organic matter can also coat the surfaces of minerals in the soil. Mercury (as a divalent cation) can bind to the sulfur species in the organic matter as well as to the bare mineral surfaces, but the extent of binding and release of this mercury is not well understood. The goals of the research were to investigate fundamental relationships among mercury, natural organic matter, and selected minerals to better understand specifically the fate and transport of mercury in contaminated soils downstream from the Y-12 plant along East Fork Poplar Creek, Tennessee, and more generally in any contaminated soil. The research focused on (1) experiments to quantify the uptake and release of mercury from two clay minerals in the soil, kaolinite and vermiculite, in the presence and absence of dissolved organic matter; (2) release of mercury from cinnabar under oxic and anoxic conditions; (3) characterization of the forms of mercury in the soil using synchrotron X-ray absorption spectroscopic techniques; and, (4) determination of molecular forms of mercury in the presence of natural organic matter. We also leveraged funding from the National Science Foundation to (5) evaluate published approaches for determining sulfur speciation in natural organic matter by fitting X-ray Absorption Near Edge Structure (XANES) spectra obtained at the sulfur K-edge and apply optimized fitting schemes to new measurements of sulfur speciation in a suite of dissolved organic matter samples from the International Humic Substances Society. Lastly, in collaboration with researchers at the University of Colorado and the U.S. Geological Survey in Boulder, Colorado, (6) we investigated the biogeochemical controls on the release of mercury in simulated flooding experiments using loose soils and intact soil cores from East Fork Poplar Creek.

  10. Final technical report; Mercury Release from Organic matter (OM) and OM-Coated Mineral Surfaces

    SciTech Connect (OSTI)

    Aiken, George

    2014-10-02

    This document is the final technical report for a project designed to address fundamental processes controlling the release of mercury from flood plain soils associated with East Fork Poplar Creek, Tennessee near the U.S. Department of Energy Oak Ridge facility. The report summarizes the activities, findings, presentations, and publications resulting from an award to the U.S. Geological that were part of a larger overall effort including Kathy Nagy (University of Illinois, Chicago, Ill) and Joseph Ryan (University of Colorado, Boulder, CO). The specific charge for the U.S.G.S. portion of the study was to provide analytical support for the larger group effort (Nagy and Ryan), especially with regard to analyses of Hg and dissolved organic matter, and to provide information about the release of mercury from the floodplain soils.

  11. Ro-vibrational Relaxation Dynamics of PbF Molecules

    SciTech Connect (OSTI)

    Neil Shafer-Ray

    2011-04-08

    In 1950 Purcell and Ramsey suggested that the electron might have a CP-violating electric dipole moment (e-EDM) proportional to its spin angular momentum. This possibility initiated an ongoing hunt for the e-EDM that has been spurred on by the recognition of the importance of CP-violation to the formation of a matter-dominated universe[2] as well as a difference in magnitude of the Supersymmetric and Standard Model[4] prediction for its value. The current limit on the e-EDM is 1.6E??27 e·cm as determined in a Ramsey beam resonance study of the Tl atom. The PbF molecule provides a unique opportunity to measure the e-EDM. The molecule??s odd electron, heavy mass, and large internal field combine to give it an intrinsic sensitivity to an e-EDM that is over three orders of magnitude bigger than that of the Tl atom. In addition to this increased intrinsic sensitivity, the ground state of the PbF molecule allows for a "magic" electric field at which the magnetic moment vanishes[7]. All of these advantages create an opportunity to significantly lower the current limit on the e-EDM. These advantages can only be realized if an intense source of ground-state PbF molecules can be created and detected with high efficiency. The scope of this project is to (1) create a rotationally cold molecular beam source of PbF, (2) achieve a continuous ionization scheme for sensitive state selective detection of the PbF molecule.

  12. STATEMENT AND ACKNOWLEDGMENT Expires:e r/o2014

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    collection of information is estimated to average 30 minutes per response, Including the time for reviewing Instructions, searching existing data sources, gathering and...

  13. Regulatory Burden RFI [76 FR 75798] | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    RFI [76 FR 75798] Regulatory Burden RFI [76 FR 75798] The following comments are provided on behalf of Ingersoll Rand [IRCO], Residential Solutions, manufacturer of Trane and American Standard residential air conditioners, heat pumps, furnaces and accessories therefore. --- Ingersoll Rand appreciates the opportunity to comment on the Department of Energy's request for information on "Reducing Regulatory Burden" in the spirit of Executive Order 13563. Reg_Review_RFI_76_FR_75798.pdf

  14. Hanford Site - 100-FR-3 | Department of Energy

    Office of Environmental Management (EM)

    FR-3 Hanford Site - 100-FR-3 July 1, 2014 - 12:00pm Addthis US Department of Energy Groundwater Database Groundwater Master Report InstallationName, State: Hanford Site, WA Responsible DOE Office: Office of Environmental Management Plume Name: 100-FR-3 Remediation Contractor: CHPRC PBS Number: 30 Report Last Updated: July 2014 with CY2013 data Contaminants Halogenated VOCs/SVOCs Present?: Yes VOC Name Concentration (ppb) Regulatory Driver Cleanup Requirement TCS 15 Yes 5 (DWS) Fuel Present? No

  15. Finding of No Significant Impact, Federal Register, 73 FR 2017...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    73 FR 2017, January 11, 2008 Document details the finding of no significant impact of the Energy-Efficient Performance Requirements for New Federal Commercial and Residential...

  16. Notice of Open Meeting, Federal Register, 64 FR 44912, August...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Notice of Open Meeting, Federal Register, 64 FR 44912, August 18, 1999 Document displays the notice of open meeting for Measurement and Verification Guidelines for Federal Energy ...

  17. Gravitomagnetic gyroscope precession in Palatini f(R) gravity

    SciTech Connect (OSTI)

    Ruggiero, Matteo Luca

    2009-04-15

    We study gravitomagnetic effects in the Palatini formalism of f(R) gravity. On using the Kerr-de Sitter metric, which is a solution of f(R) field equations, we calculate the impact of f(R) gravity on the gravitomagnetic precession of an orbiting gyroscope. We show that, even though an f(R) contribution is present in principle, its magnitude is negligibly small and far to be detectable in the present (like GP-B) and foreseeable space missions or observational tests around the Earth.

  18. Notice of Public Meeting, Federal Register, 66 FR 50177, October...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    FR 50177, October 2, 2001 Document displays a notice of public meeting for Federal Purchasing of Energy-Efficient Standby Power Devices, which was published in the Federal...

  19. Notice of Proposed Rulemaking, Federal Register, 72 FR 33696...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    on June 19, 2007. PDF icon 72fr33696.pdf More Documents & Publications Chronological History of Federal Energy-Efficient Product Procurement: Executive, Legislative and...

  20. A polynomial f(R) inflation model

    SciTech Connect (OSTI)

    Huang, Qing-Guo

    2014-02-19

    Motivated by the ultraviolet complete theory of quantum gravity, for example the string theory, we investigate a polynomial f(R) inflation model in detail. We calculate the spectral index and tensor-to-scalar ratio in the f(R) inflation model with the form of f(R)=R+((R{sup 2})/(6M{sup 2}))+((λ{sub n})/(2n))((R{sup n})/((3M{sup 2}){sup n−1})). Compared to Planck 2013, we find that R{sup n} term should be exponentially suppressed, i.e. |λ{sub n}|≲10{sup −2n+2.6}.

  1. Microsoft Word - S08406_MND_OM_Plan.docx

    Office of Legacy Management (LM)

    ... the Owner's intention to enter into this Environmental ... based on a complete search of DOE files, the ... carcinogen is reported in terms of the incremental lifetime ...

  2. OM-300 - MWD Geothermal Navigation Instrument Geothermal Project...

    Open Energy Info (EERE)

    Principal Investigators Bruce Ohme, Principal Engineer, Honeywell International; Bill Goodman, President, Applied Physics Systems (APS) Targets Milestones A Directional and...

  3. Microsoft Word - S08406_MND_OM_Plan.docx

    Office of Legacy Management (LM)

    ... and pursuant to the authority of the Atomic Energy Act of 1954, Section 161 (g) ... of an 80 acre tract as conveyed from Ray C. Dunaway and Thelma Mae Dunaway to Oak ...

  4. Bounce cosmology from F(R) gravity and F(R) bigravity

    SciTech Connect (OSTI)

    Bamba, Kazuharu; Nojiri, Shin'ichi; Makarenko, Andrey N.; Odintsov, Sergei D.; Myagky, Alexandr N. E-mail: andre@tspu.edu.ru E-mail: nojiri@phys.nagoya-u.ac.jp

    2014-01-01

    We reconstruct F(R) gravity models with exponential and power-law forms of the scale factor in which bounce cosmology can be realized. We explore the stability of the reconstructed models with analyzing the perturbations from the background solutions. Furthermore, we study an F(R) gravity model with a sum of exponentials form of the scale factor, where the bounce in the early universe as well as the late-time cosmic acceleration can be realized in a unified manner. As a result, we build a second order polynomial type model in terms of R and show that it could be stable. Moreover, when the scale factor is expressed by an exponential form, we derive F(R) gravity models of a polynomial type in case of the non-zero spatial curvature and that of a generic type in that of the zero spatial curvature. In addition, for an exponential form of the scale factor, an F(R) bigravity model realizing the bouncing behavior is reconstructed. It is found that in both the physical and reference metrics the bouncing phenomenon can occur, although in general the contraction and expansion rates are different each other.

  5. Executive Order 13212: 66 FR 28357 (22 May 2001)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Executive Order 13212: 66 FR 28357 (22 May 2001) Executive Order 13212--Actions To Expedite Energy-Related Projects May 18, 2001 By the authority vested in me as President by the ...

  6. AmeriFlux US-FR3 Freeman Ranch- Woodland

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Heilman, Jim [Texas A& M University

    2016-01-01

    This is the AmeriFlux version of the carbon flux data for the site US-FR3 Freeman Ranch- Woodland. Site Description - Dense canopy of live oak and Ashe juniper

  7. Corrections Notice, Federal Register, 71 FR 10097, February 28, 2006 |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Corrections Notice, Federal Register, 71 FR 10097, February 28, 2006 Corrections Notice, Federal Register, 71 FR 10097, February 28, 2006 Document displays a correction notice pertaining to Energy Conservation Standards for New Federal Commercial and Multi-Family High-Rise Residential Buildings and New Federal Low-Rise Residential Buildings, which was published in the Federal Register on February 28, 2006. Download the corrections notice document. (33.34 KB) More

  8. Isotope shifts in francium isotopes Fr 206 - 213 and Fr 221

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Collister, R.; Gwinner, G.; Tandecki, M.; Behr, J. A.; Pearson, M. R.; Zhang, J.; Orozco, L. A.; Aubin, S.; Gomez, E.; FrPNC Collaboration

    2014-11-07

    We present the isotope shifts of the 7s1/2 to 7p1/2 transition for francium isotopes ²⁰⁶⁻²¹³Fr with reference to ²²¹Fr collected from two experimental periods. The shifts are measured on a sample of atoms prepared within a magneto-optical trap by a fast sweep of radio-frequency sidebands applied to a carrier laser. King plot analysis, which includes literature values for 7s1/2 to 7p3/2 isotope shifts, provides a field shift constant ratio of 1.0520(10) and a difference between the specific mass shift constants of 170(100) GHz amu between the D₁ and D₂ transitions, of sufficient precision to differentiate between ab initio calculations.

  9. Notice of Open Meeting, Federal Register, 64 FR 44912, August 18, 1999 |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Open Meeting, Federal Register, 64 FR 44912, August 18, 1999 Notice of Open Meeting, Federal Register, 64 FR 44912, August 18, 1999 Document displays the notice of open meeting for Measurement and Verification Guidelines for Federal Energy Projects, which was published in the Federal Register on August 18, 1999. Download the notice of open meeting document. (46.25 KB) More Documents & Publications Notice of Availability, Federal Register, 64 FR 3492, January 22, 1999

  10. Microsoft Word - Loan Guarantee NOPR -Final_5-09-07_FR 2 _2_.doc |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Loan Guarantee NOPR -Final_5-09-07_FR 2 _2_.doc Microsoft Word - Loan Guarantee NOPR -Final_5-09-07_FR 2 _2_.doc Microsoft Word - Loan Guarantee NOPR -Final_5-09-07_FR 2 _2_.doc (160.81 KB) More Documents & Publications Notice of Proposed Rulemaking (August 6, 2009) Notice of Proposed Rulemaking (May 16, 2007) Final Rule (December 4, 2009)

  11. DOE Hydrogen Transition Analysis Workshop: Final Agenda

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    T Th hu ur rs sd da ay y ( (R Ro oo om m G GH H- -0 01 19 ... am HyTrans Model - David Greene, ORNL 10:10 am Market ... Marianne Mintz (ANL), and Mark Ruth (NREL) 12:00 pm Lunch ...

  12. Asteroseismic analysis of the CoRoT target HD 49933

    SciTech Connect (OSTI)

    Liu, Zhie; Yang, Wuming; Bi, Shaolan; Tian, Zhijia; Liu, Kang; Ge, Zhishuai; Yu, Jie; He, Xin; Wu, Yaqian; Chintarungruangchai, P.; Li, Tanda; Tan, Xiaoyan

    2014-01-10

    The frequency ratios r {sub 10} and r {sub 01} of HD 49933 exhibit an increase at high frequencies. This behavior also exists in the ratios of other stars, which is considered to result from the low signal-to-noise ratio and the larger linewidth at the high-frequency end and could not be predicted by stellar models in previous work. Our calculations show that the behavior not only can be reproduced by stellar models, but can be predicted by asymptotic formulas of the ratios. The frequency ratios of the Sun, too, can be reproduced well by the asymptotic formulas. The increased behavior derives from the fact that the gradient of mean molecular weight at the bottom of the radiative region hinders the propagation of p-modes, while the hindrance does not exist in the convective core. This behavior should exist in the ratios of stars with a large convective core. The characteristic of the ratios at high frequencies provides a strict constraint on stellar models and aids in determining the size of the convective core and the extent of overshooting. Observational constraints point to a star with M = 1.28 0.01 M {sub ?}, R = 1.458 0.005 R {sub ?}, t = 1.83 0.1 Gyr, r{sub cc} = 0.16 0.02 R {sub ?}, ? = 1.85 0.05, and ?{sub ov} =0.6 0.2 for HD 49933.

  13. STANDING ORDER 1. Standing Order Number: EP-DIV-S0-20222, R.O

    Office of Environmental Management (EM)

    , ;, . USQ Qualified E1 luator (QEV) JLl. p M r .L .. r- c. 'i:> i" L v....ur- 1 rA .?4-- L1 I 2.t::.c'-- 0- 0 Print name Signa Date ERID-257356 Verified...

  14. Tools_Equipment under 10K RO 23_120213.xlsx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... 1,217.85 OFF PITT 11-Oct-13 23 0000106669 DRY KEEPER SANPLA 08 SAMPLA NA NA 1,222.48 ... S17131 WASHER GLASSWARE LABCONCO FLASK SCRUBBER 704226 4,722.85 83 221 24-Sep-13 23 ...

  15. Constraints on a f(R) gravity dark energy model with early scaling evolution

    SciTech Connect (OSTI)

    Park, Chan-Gyung; Hwang, Jai-chan; Noh, Hyerim E-mail: jchan@knu.ac.kr

    2011-09-01

    The modified gravity with f(R) = R{sup 1+?} (? > 0) allows a scaling solution where the energy density of gravity sector follows the energy density of the dominant fluid. We present initial conditions of background and perturbation variables during the scaling evolution regime in the modified gravity. As a possible dark energy model we consider a gravity with a form f(R) = R{sup 1+?}+qR{sup ?n} (?1 < n ? 0) where the second term drives the late-time acceleration. We show that our f(R) gravity parameters are very sensitive to the baryon perturbation growth and baryon density power spectrum, and present observational constraints on the model parameters. We consider full perturbations of f(R) gravity. Our analysis suggests that only the parameter space extremely close to the ?CDM model is allowed with ??<5 10{sup ?6} and n?>?10{sup ?4}.

  16. Cosmological bounces in spatially flat FRW spacetimes in metric f(R) gravity

    SciTech Connect (OSTI)

    Paul, Niladri; Chakrabarty, Saikat Nil; Bhattacharya, Kaushik E-mail: snilch@iitk.ac.in

    2014-10-01

    The present work analyzes the various conditions in which there can be a bouncing universe solution in f(R) gravity. In the article an interesting method, to analyze the bouncing FRW solutions in a spatially flat universe using f(R) gravity models using an effective Einstein frame description of the process, is presented. The analysis shows that a cosmological bounce in the f(R) theory need not be described by an equivalent bounce in the Einstein frame description of the process where actually there may be no bounce at all. Nevertheless the Einstein frame description of the bouncing phenomena turns out to be immensely important as the dynamics of the bounce becomes amenable to logic based on general relativistic intuition. The theory of scalar cosmological perturbations in the bouncing universe models in f(R) theories has also been worked out in the Einstein frame.

  17. Notice of Availability, Federal Register, 75 FR 78231, December 15, 2010 |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy 75 FR 78231, December 15, 2010 Notice of Availability, Federal Register, 75 FR 78231, December 15, 2010 Notice of availability for the Management of Energy and Water Efficiency in Federal Buildings, which was published in the Federal Register on December 15, 2010. Download the notice of availability for the management of energy and water efficiency in federal buildings. (85.16 KB) More Documents & Publications FUPWG Spring 2011 Washington, D.C., Update Federal

  18. Proposed Rule Correction, Federal Register, 75 FR 66008, October 27, 2010 |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Proposed Rule Correction, Federal Register, 75 FR 66008, October 27, 2010 Proposed Rule Correction, Federal Register, 75 FR 66008, October 27, 2010 Document displays a correction to the notice of proposed rulemaking for Fossil Fuel-Generated Energy Consumption Reduction for New Federal Buildings and Major Renovations of Federal Buildings, which was published in the Federal Register on October 15, 2010. Download the correction to the notice of proposed rulemaking. (89.88

  19. Comparison of PWR-IMF and FR fuel cycles

    SciTech Connect (OSTI)

    Darilek, Petr; Zajac, Radoslav; Breza, Juraj |; Necas, Vladimir

    2007-07-01

    The paper gives a comparison of PWR (Russia origin VVER-440) cycle with improved micro-heterogeneous inert matrix fuel assemblies and FR cycle. Micro-heterogeneous combined assembly contains transmutation pins with Pu and MAs from burned uranium reprocessing and standard uranium pins. Cycle analyses were performed by HELIOS spectral code and SCALE code system. Comparison is based on fuel cycle indicators, used in the project RED-IMPACT - part of EU FP6. Advantages of both closed cycles are pointed out. (authors)

  20. Precipitation of sigma and chi phases in ?-ferrite of Type 316FR weld metals

    SciTech Connect (OSTI)

    Chun, Eun Joon; Baba, Hayato; Nishimoto, Kazutoshi; Saida, Kazuyoshi

    2013-12-15

    The decomposition behavior and kinetics of ?-ferrite are examined using aging treatments between 873 and 1073 K for Type 316FR stainless steel weld metals with different solidification modes (316FR AF, 316FR FA). The dominant precipitates are sigma, chi, and secondary austenite nucleated at ?-ferrite/austenite interfaces or in the interior of the ferrite grains. These precipitates consume all the ferrite during isothermal aging in both 316FR AF and FA weld metals. Differences in the precipitation behavior (precipitation initiation time and precipitation speed) between weld metals can be explained by i) the degree of Cr and Mo microsegregation within ?-ferrite or austenite near ferrite and ii) the nucleation sites induced due to the solidification mode (AF or FA), such as the ferrite amount. For both weld materials, a JohnsonMehl-type equation can express the precipitation behavior of the sigma + chi phases and quantitatively predict the behavior at the service-exposure temperatures of a fast breed reactor. - Highlights: Precipitation of ? and ? phase in Type 316FR welds (two solidification modes) Different precipitation behaviors: precipitation initiation time and growth speed Johnson-Mehltype equation is the most applicable to the precipitation behaviors Precipitation behaviors are predicted under service conditions of FBRs.

  1. Further stable neutron star models from f(R) gravity

    SciTech Connect (OSTI)

    Astashenok, Artyom V.; Capozziello, Salvatore; Odintsov, Sergei D. E-mail: capozziello@na.infn.it

    2013-12-01

    Neutron star models in perturbative f(R) gravity are considered with realistic equations of state. In particular, we consider the FPS, SLy and other equations of state and a case of piecewise equation of state for stars with quark cores. The mass-radius relations for f(R) = R+R(e{sup ?R/R{sub 0}}?1) model and for R{sup 2} models with logarithmic and cubic corrections are obtained. In the case of R{sup 2} gravity with cubic corrections, we obtain that at high central densities (? > 10?{sub ns}, where ?{sub ns} = 2.7 10{sup 14} g/cm{sup 3} is the nuclear saturation density), stable star configurations exist. The minimal radius of such stars is close to 9 km with maximal mass ? 1.9M{sub ?} (SLy equation). A similar situation takes place for AP4 and BSK20 EoS. Such an effect can give rise to more compact stars than in General Relativity. If observationally identified, such objects could constitute a formidable signature for modified gravity at astrophysical level. Another interesting result can be achieved in modified gravity with only a cubic correction. For some EoS, the upper limit of neutron star mass increases and therefore these EoS can describe realistic star configurations (although, in General Relativity, these EoS are excluded by observational constraints)

  2. U.S. Geological Survey Open-File Report 99-310

    National Nuclear Security Administration (NNSA)

    r e d fr om Gr a v i t y D a ta , Ne va da Test Si te , N e va da by G.A. Phelps 1 , V.E. ... Figure 1. Map showing simplified geology of the Nevada Test Site region. White, Cenozoic ...

  3. Notice of Proposed Rulemaking, Federal Register, 75 FR 63404, 10 CFR Parts

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    433 and 435, October 15, 2010 | Department of Energy 63404, 10 CFR Parts 433 and 435, October 15, 2010 Notice of Proposed Rulemaking, Federal Register, 75 FR 63404, 10 CFR Parts 433 and 435, October 15, 2010 Document details the notice of proposed rulemaking for Fossil Fuel-Generated Energy Consumption Reduction for New Federal Buildings and Major Renovations of Federal Buildings, which was published in the Federal Register on October 15, 2010. 75_fr_63404.pdf (199.77 KB) More Documents

  4. Interim Final Rule and Request for Comments, Federal Register, 71 FR 70275,

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    10 CFR Part 433, 434, and 435, December 4, 2006 | Department of Energy Interim Final Rule and Request for Comments, Federal Register, 71 FR 70275, 10 CFR Part 433, 434, and 435, December 4, 2006 Interim Final Rule and Request for Comments, Federal Register, 71 FR 70275, 10 CFR Part 433, 434, and 435, December 4, 2006 Document displays the interim final rule and request for comments for Energy Conservation Standards for New Federal Commercial and Multi-Family High-Rise Residential Buildings

  5. AWEA O&M Recommended Practices Series Part VII: Wind Turbine Gear Lubricant Flushing Procedures

    Broader source: Energy.gov [DOE]

    The AWEA Operations and Maintenance Recommended Practice 101 was developed to provide guidance to the wind industry regarding proper methods of wind turbine gearbox flushing and oil conversion...

  6. OM 14-66; Board's Interest Rate Remains 3 Percent for the Fourth...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    However, no case may be in the program for more than 60 days. * The preferred method of conducting settlement conferences is to have the parties or their representatives attend in ...

  7. Effective O&M Policy in Public Buildings (Text Version) | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... states, cities, and counties and tribes to connect with technical and program experts and ... The blog is updated frequently with energy ... But we can't as communities just keep going ...

  8. Duck Valley Reservoirs Fish Stocking and O&M, Annual Progress Report 2007-2008.

    SciTech Connect (OSTI)

    Sellman, Jake; Perugini, Carol

    2009-02-20

    The Duck Valley Reservoirs Fish Stocking and Operations and Maintenance Project (DV Fisheries) is an ongoing resident fish program that serves to partially mitigate the loss of anadromous fish that resulted from downstream construction of the federal hydropower system. The project's goals are to enhance subsistence fishing and educational opportunities for Tribal members of the Shoshone-Paiute Tribes and provide fishing opportunities for non-Tribal members. In addition to stocking rainbow trout (Oncorhynchus mykiss) in Mountain View (MVR), Lake Billy Shaw (LBS), and Sheep Creek Reservoirs (SCR), the program is also designed to: maintain healthy aquatic conditions for fish growth and survival, provide superior facilities with wilderness qualities to attract non-Tribal angler use, and offer clear, consistent communication with the Tribal community about this project as well as outreach and education within the region and the local community. Tasks for this performance period fall into three categories: operations and maintenance, monitoring and evaluation, and public outreach. Operation and maintenance of the three reservoirs include maintaining fences, roads, dams and all reservoir structures, feeder canals, water troughs, stock ponds, educational signs, vehicles, equipment, and restroom facilities. Monitoring and evaluation activities include creel, gillnet, wildlife, and bird surveys, water quality and reservoir structures monitoring, native vegetation planting, photo point documentation, and control of encroaching exotic vegetation. Public outreach activities include providing environmental education to school children, providing fishing reports to local newspapers and vendors, updating the website, hosting community environmental events, and fielding numerous phone calls from anglers. The reservoir monitoring program focuses on water quality and fishery success. Sheep Creek Reservoir and Lake Billy Shaw had less than productive trout growth due to water quality issues including dissolved oxygen and/or turbidity. Regardless, angler fishing experience was the highest at Lake Billy Shaw. Trout in Mountain View Reservoir were in the best condition of the three reservoirs and anglers reported very good fishing there. Water quality (specifically dissolved oxygen and temperature) remain the main limiting factors in the fisheries, particularly in late August to early September.

  9. Webinar: AWEA O&M Committee Webinar: First Quarter Committee Update (2016)

    Broader source: Energy.gov [DOE]

    Join the America Wind Energy Association's (AWEA's) O&M Committee for the first quarterly update of 2016. You will learn about upcoming goals for the next 18 months, committee benchmarks and...

  10. Notice of Proposed Rulemaking, Federal Register, 75 FR 29933, 10 CFR Parts

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    433 and 435, May 28, 2010 | Department of Energy 29933, 10 CFR Parts 433 and 435, May 28, 2010 Notice of Proposed Rulemaking, Federal Register, 75 FR 29933, 10 CFR Parts 433 and 435, May 28, 2010 Document details the notice of proposed rulemaking for Energy Efficiency and Sustainable Design Standards for New Federal Buildings, which was published in the Federal Register on May 28, 2010. Download the notice of proposed rulemaking document. (180.74 KB) More Documents & Publications

  11. Background cosmological dynamics in f(R) gravity and observational constraints

    SciTech Connect (OSTI)

    Ali, Amna; Sami, M.; Sen, Anjan A.; Gannouji, Radouane

    2010-05-15

    In this paper, we carry out a study of viable cosmological models in f(R) gravity at the background level. We use observable parameters like {Omega} and {gamma} to form an autonomous system of equations and show that the models under consideration exhibit two different regimes in their time evolution, namely, a phantom phase followed by a quintessencelike behavior. We employ state finder parameters to emphasize a characteristic discriminative signature of these models.

  12. AmeriFlux US-FR2 Freeman Ranch- Mesquite Juniper

    DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

    Litvak, Marcy [University of New Mexico

    2016-01-01

    This is the AmeriFlux version of the carbon flux data for the site US-FR2 Freeman Ranch- Mesquite Juniper. Site Description - Freeman Ranch is a 4200 ha research area owned by Texas State University. It is located on the easter Edwards Plateau in central Texas and overlies and recharges the Edwards Aquifer. Most of the ranch is occupied by upland habitats.

  13. Distorting general relativity: gravity's rainbow and f(R) theories at work

    SciTech Connect (OSTI)

    Garattini, Remo

    2013-06-01

    We compute the Zero Point Energy in a spherically symmetric background combining the high energy distortion of Gravity's Rainbow with the modification induced by a f(R) theory. Here f(R) is a generic analytic function of the Ricci curvature scalar R in 4D and in 3D. The explicit calculation is performed for a Schwarzschild metric. Due to the spherically symmetric property of the Schwarzschild metric we can compare the effects of the modification induced by a f(R) theory in 4D and in 3D. We find that the final effect of the combined theory is to have finite quantities that shift the Zero Point Energy. In this context we setup a Sturm-Liouville problem with the cosmological constant considered as the associated eigenvalue. The eigenvalue equation is a reformulation of the Wheeler-DeWitt equation which is analyzed by means of a variational approach based on gaussian trial functionals. With the help of a canonical decomposition, we find that the relevant contribution to one loop is given by the graviton quantum fluctuations around the given background. A final discussion on the connection of our result with the observed cosmological constant is also reported.

  14. The New Affordable Zero Homes Project

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    TransfOrmaTiOn frOm TyPiCaL duPLex TO new affOrdabLe ZerO hOmes: sOuTh eLevaTiOn: Typical ... Pv dOubLe sided CeLL: Pv LighT absOrPTiOn: Double Sided Cell. Digital image. LG NeON 2 ...

  15. Generalized uncertainty principle in f(R) gravity for a charged black hole

    SciTech Connect (OSTI)

    Said, Jackson Levi; Adami, Kristian Zarb

    2011-02-15

    Using f(R) gravity in the Palatini formularism, the metric for a charged spherically symmetric black hole is derived, taking the Ricci scalar curvature to be constant. The generalized uncertainty principle is then used to calculate the temperature of the resulting black hole; through this the entropy is found correcting the Bekenstein-Hawking entropy in this case. Using the entropy the tunneling probability and heat capacity are calculated up to the order of the Planck length, which produces an extra factor that becomes important as black holes become small, such as in the case of mini-black holes.

  16. FEMP Training Success Story: O&M Best practices for Small-Scale PV Systems Video Transcript

    Broader source: Energy.gov [DOE]

    The United States Department of Energy’s Federal Energy Management Program partnered with the Department of the Interior’s US Fish & Wildlife Service to produce much needed training that...

  17. Structural And Functional Analysis of the Ligand Specificity of the HtrA2/OmI PDZ Domain

    SciTech Connect (OSTI)

    Zhang, Y.; Appleton, B.A.; Wu, P.; Wiesmann, C.; Sidhu, S.S.

    2009-06-04

    The mitochondrial serine protease HtrA2/Omi helps to maintain mitochondrial function by handling misfolded proteins in the intermembrane space. In addition, HtrA2/Omi has been implicated as a proapoptotic factor upon release into the cytoplasm during the cell death cascade. The protein contains a C-terminal PDZ domain that packs against the protease active site and inhibits proteolytic activity. Engagement of the PDZ domain by peptide ligands has been shown to activate the protease and also has been proposed to mediate substrate recognition. We report a detailed structural and functional analysis of the human HtrA2/Omi PDZ domain using peptide libraries and affinity assays to define specificity, X-ray crystallography to view molecular details of PDZ-ligand interactions, and alanine-scanning mutagenesis to probe the peptide-binding groove. We show that the HtrA2/Omi PDZ domain recognizes both C-terminal and internal stretches of extended, hydrophobic polypeptides. High-affinity ligand recognition requires contacts with up to five hydrophobic side chains by distinct sites on the PDZ domain. However, no particular residue type is absolutely required at any position, and thus, the HtrA2/Omi PDZ domain appears to be a promiscuous module adapted to recognize unstructured, hydrophobic polypeptides. This type of specificity is consistent with the biological role of HtrA2/Omi in mitochondria, which requires the recognition of diverse, exposed stretches of hydrophobic sequences in misfolded proteins. The findings are less consistent with, but do not exclude, a role for the PDZ domain in targeting the protease to specific substrates during apoptosis.

  18. Wind Turbine Condition Monitoring, Reliability Database, and O&M Research Update; NREL (National Renewable Energy Laboratory)

    SciTech Connect (OSTI)

    Sheng, S.

    2015-02-01

    This presentation provides updates on the work conducted for the Gearbox Reliability Collaborative on the gearbox reliability database, condition monitoring and operations and maintenance research.

  19. Field Results from Application of the Outdoor-Air/Economizer Diagnostician for Commissioning and O&M

    SciTech Connect (OSTI)

    Pratt, Robert G.; Katipamula, Srinivas; Brambley, Michael R.; Blanc, Steven L.

    2000-05-31

    This paper presents results of field testing an automated diagnostician for outdoor-air-supply and economizer systems that can be used for commissioning purposes. The fundamental capabilities of the tool are described and key results of its application on six air handlers in a large hotel building are discussed. Ancillary issues pertinent to the development and application of such tools are also presented.

  20. Constraining models of f(R) gravity with Planck and WiggleZ power spectrum data

    SciTech Connect (OSTI)

    Dossett, Jason; Parkinson, David; Hu, Bin E-mail: hu@lorentz.leidenuniv.nl

    2014-03-01

    In order to explain cosmic acceleration without invoking ''dark'' physics, we consider f(R) modified gravity models, which replace the standard Einstein-Hilbert action in General Relativity with a higher derivative theory. We use data from the WiggleZ Dark Energy survey to probe the formation of structure on large scales which can place tight constraints on these models. We combine the large-scale structure data with measurements of the cosmic microwave background from the Planck surveyor. After parameterizing the modification of the action using the Compton wavelength parameter B{sub 0}, we constrain this parameter using ISiTGR, assuming an initial non-informative log prior probability distribution of this cross-over scale. We find that the addition of the WiggleZ power spectrum provides the tightest constraints to date on B{sub 0} by an order of magnitude, giving log{sub 10}(B{sub 0}) < ?4.07 at 95% confidence limit. Finally, we test whether the effect of adding the lensing amplitude A{sub Lens} and the sum of the neutrino mass ?m{sub ?} is able to reconcile current tensions present in these parameters, but find f(R) gravity an inadequate explanation.

  1. Neutron stars in a perturbative f(R) gravity model with strong magnetic fields

    SciTech Connect (OSTI)

    Cheoun, Myung-Ki; Deliduman, Cemsinan; Gngr, Can; Kele?, Vildan; Ryu, C.Y.; Kajino, Toshitaka; Mathews, Grant J. E-mail: cemsinan@msgsu.edu.tr E-mail: kelesvi@itu.edu.tr E-mail: kajino@nao.ac.jp

    2013-10-01

    In Kaluza-Klein electromagnetism it is natural to associate modified gravity with strong electromagnetic fields. Hence, in this paper we investigate the combined effects of a strong magnetic field and perturbative f(R) gravity on the structure of neutron stars. The effect of an interior strong magnetic field of about 10{sup 17?18} G on the equation of state is derived in the context of a quantum hadrodynamics (QHD) equation of state (EoS) including effects of the magnetic pressure and energy along with occupied Landau levels. Adopting a random orientation of interior field domains, we solve the modified spherically symmetric hydrostatic equilibrium equations derived for a gravity model with f(R) = R+?R{sup 2}. Effects of both the finite magnetic field and the modified gravity are detailed for various values of the magnetic field and the perturbation parameter ? along with a discussion of their physical implications. We show that there exists a parameter space of the modified gravity and the magnetic field strength, in which even a soft equation of state can accommodate a large ( > 2 M{sub s}un) maximum neutron star mass.

  2. Photometric properties for selected Algol-type binaries. VI. The newly discovered oEA star FR Orionis

    SciTech Connect (OSTI)

    Yang, Y.-G.; Wei, J.-Y.; Li, H.-L.

    2014-02-01

    New photometry of the neglected eclipsing binary FR Orionis was obtained in 2012 November and December. Using the updated Wilson-Devinney program, the photometric elements were deduced from two-color light curves. The results indicate that this system is a semi-detached binary, with a mass ratio of 0.325(± 0.002) and a fill-out factor of the primary of f{sub p} = 73.5(± 0.2)%. The oscillating light curves imply that FR Ori may be an oscillating EA (oEA)-type star with a rapidly pulsating, mass-accreting primary component. After we removed the theoretical light curves from the observations, Fourier analysis revealed that the more massive component possibly shows a δ Scuti type pulsation with four detected frequencies. The dominant frequency is f {sub 1} = 38.6c day{sup –1} (i.e., P {sub puls} = 37.3 minutes), and the pulsation constant is Q = 0.014 days. Based on all available eclipsing times, the orbital period is undergoing a secular period increase with a rate of dP/dt = +8.85(±0.66) × 10{sup –8} day yr {sup –1}, which may be interpreted by mass transfer from the secondary to the primary. We expect that the more massive component will fill its Roche lobe due to mass transfer of the secondary. Therefore, the oEA star FR Ori may evolve into a contact configuration.

  3. NEW ACCURATE MEASUREMENT OF {sup 36}ArH{sup +} AND {sup 38}ArH{sup +} RO-VIBRATIONAL TRANSITIONS BY HIGH RESOLUTION IR ABSORPTION SPECTROSCOPY

    SciTech Connect (OSTI)

    Cueto, M.; Herrero, V. J.; Tanarro, I.; Doménech, J. L.; Cernicharo, J.; Barlow, M. J.; Swinyard, B. M.

    2014-03-01

    The protonated argon ion, {sup 36}ArH{sup +}, was recently identified in the Crab Nebula from Herschel spectra. Given the atmospheric opacity at the frequency of its J = 1-0 and J = 2-1 rotational transitions (617.5 and 1234.6 GHz, respectively), and the current lack of appropriate space observatories after the recent end of the Herschel mission, future studies on this molecule will rely on mid-infrared observations. We report on accurate wavenumber measurements of {sup 36}ArH{sup +} and {sup 38}ArH{sup +} rotation-vibration transitions in the v = 1-0 band in the range 4.1-3.7 μm (2450-2715 cm{sup –1}). The wavenumbers of the R(0) transitions of the v = 1-0 band are 2612.50135 ± 0.00033 and 2610.70177 ± 0.00042 cm{sup –1} (±3σ) for {sup 36}ArH{sup +} and {sup 38}ArH{sup +}, respectively. The calculated opacity for a gas thermalized at a temperature of 100 K and with a linewidth of 1 km s{sup –1} of the R(0) line is 1.6 × 10{sup –15} × N({sup 36}ArH{sup +}). For column densities of {sup 36}ArH{sup +} larger than 1 × 10{sup 13} cm{sup –2}, significant absorption by the R(0) line can be expected against bright mid-IR sources.

  4. Optical and ultraviolet observations of the narrow-lined type Ia SN 2012fr in NGC 1365

    SciTech Connect (OSTI)

    Zhang, Ju-Jia; Bai, Jin-Ming; Wang, Bo; Liu, Zheng-Wei [Yunnan Observatories (YNAO), Chinese Academy of Sciences, Kunming 650011 (China); Wang, Xiao-Feng; Zhao, Xu-Lin; Chen, Jun-Cheng [Physics Department and Tsinghua Center for Astrophysics (THCA), Tsinghua University, Beijing 100084 (China); Zhang, Tian-Meng, E-mail: jujia@ynao.ac.cn, E-mail: baijinming@ynao.ac.cn, E-mail: wang_xf@mail.tsinghua.edu.cn [National Astronomical Observatories of China (NAOC), Chinese Academy of Sciences, Beijing 100012 (China)

    2014-07-01

    Extensive optical and ultraviolet (UV) observations of the type Ia supernova (SN Ia) 2012fr are presented in this paper. It has a relatively high luminosity, with an absolute B-band peak magnitude of about 19.5 mag and a smaller post-maximum decline rate than normal SNe Ia (e.g., ?m {sub 15}(B) =0.85 0.05 mag). Based on the UV and optical light curves, we derived that a {sup 56}Ni mass of about 0.88 M {sub ?} was synthesized in the explosion. The earlier spectra are characterized by noticeable high-velocity features of Si II ?6355 and Ca II with velocities in the range of ?22, 000-25, 000 km s{sup 1}. At around the maximum light, these spectral features are dominated by the photospheric components which are noticeably narrower than normal SNe Ia. The post-maximum velocity of the photosphere remains almost constant at ?12,000 km s{sup 1} for about one month, reminiscent of the behavior of some luminous SNe Ia like SN 1991T. We propose that SN 2012fr may represent a subset of the SN 1991T-like SNe Ia viewed in a direction with a clumpy or shell-like structure of ejecta, in terms of a significant level of polarization reported in Maund et al. in 2013.

  5. Data validation report for the 100-FR-3 Operable Unit, third round groundwater samples

    SciTech Connect (OSTI)

    Ayres, J.M.

    1994-03-31

    Westinghouse-Hanford has requested that a minimum of 20% of the total number of Sample Delivery Groups be validated for the 100-FR-3 operable Unit Third Round Groundwater sampling investigation. Therefore, the data from the chemical analysis of 51 samples from this sampling event and their related quality assurance samples were reviewed and validated to verify that reported sample results were of sufficient quality to support decisions regarding remedial actions performed at this site. The report is broken down into sections for each chemical analysis and radiochemical analysis type. Each section addresses the data package completeness, holding time adherence, instrument calibration and tuning acceptability, blank results, accuracy, precision, system performance, as well as the compound identification and quantitation. In addition, each section has an overall assessment and summary for the data packages reviewed for the particular chemical/radiochemical analyses. Detailed backup information is provided to the reader by SDG No. and sample number. For each data package, a matrix of chemical analyses per sample number is presented, as well as data qualification summaries.

  6. MODELING THE NONLINEAR CLUSTERING IN MODIFIED GRAVITY MODELS. I. A FITTING FORMULA FOR THE MATTER POWER SPECTRUM OF f(R) GRAVITY

    SciTech Connect (OSTI)

    Zhao, Gong-Bo

    2014-04-01

    Based on a suite of N-body simulations of the Hu-Sawicki model of f(R) gravity with different sets of model and cosmological parameters, we develop a new fitting formula with a numeric code, MGHalofit, to calculate the nonlinear matter power spectrum P(k) for the Hu-Sawicki model. We compare the MGHalofit predictions at various redshifts (z ? 1) to the f(R) simulations and find that the relative error of the MGHalofit fitting formula of P(k) is no larger than 6% at k ? 1 h Mpc{sup 1} and 12% at k in (1, 10] h Mpc{sup 1}, respectively. Based on a sensitivity study of an ongoing and a future spectroscopic survey, we estimate the detectability of a signal of modified gravity described by the Hu-Sawicki model using the power spectrum up to quasi-nonlinear scales.

  7. Structural health and prognostics management for the enhancement of offshore wind turbine operations and maintenance strategies. Structural health and prognostics management for offshore O&M

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Griffith, D. Todd; Yoder, Nathanael C.; Resor, Brian; White, Jonathan; Paquette, Joshua

    2013-09-19

    Offshore wind turbines are an attractive source for clean and renewable energy for reasons including their proximity to population centers and higher capacity factors. One obstacle to the more widespread installation of offshore wind turbines in the USA, however, is that recent projections of offshore operations and maintenance costs vary from two to five times the land-based costs. One way in which these costs could be reduced is through use of a structural health and prognostics management (SHPM) system as part of a condition-based maintenance paradigm with smart loads management. Our paper contributes to the development of such strategies bymoredeveloping an initial roadmap for SHPM, with application to the blades. One of the key elements of the approach is a multiscale simulation approach developed to identify how the underlying physics of the system are affected by the presence of damage and how these changes manifest themselves in the operational response of a full turbine. A case study of a trailing edge disbond is analysed to demonstrate the multiscale sensitivity of damage approach and to show the potential life extension and increased energy capture that can be achieved using simple changes in the overall turbine control and loads management strategy. Finally, the integration of health monitoring information, economic considerations such as repair costs versus state of health, and a smart loads management methodology provides an initial roadmap for reducing operations and maintenance costs for offshore wind farms while increasing turbine availability and overall profit.less

  8. DOE Announces Webinars on the Buildings of the Future Research Project, O&M Best Practices for Small PV Systems, and More

    Office of Energy Efficiency and Renewable Energy (EERE)

    EERE offers webinars to the public on a range of subjects, from adopting the latest energy efficiency and renewable energy technologies, to training for the clean energy workforce. Webinars are free; however, advanced registration is typically required. You can also watch archived webinars and browse previously aired videos, slides, and transcripts.

  9. Agenda for the Hydrogen Delivery and Onboard Storage Analysis Workshop

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    January 25, 2006 U.S. Department of Energy Forrestal Building, Room GJ-015 1000 Independence Avenue, SW Washington, DC 20585 F FI IN NA AL L A AG GE EN ND DA A J Ja an nu ua ar ry y 2 25 5, , W We ed dn ne es sd da ay y ( (R Ro oo om m G GJ J- -0 01 15 5) ) (attendance is limited to members of the FreedomCAR & Fuel Partnership Tech Teams and invited presenters) 8:00 am Registration 8:30 am Welcome and Introductions 8:45 am Agenda and Purpose - Mark Paster, DOE-HFCIT 9:00 am On-Board Storage

  10. News Flash - HPMC Occupational Health Services

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    About HPMC OMS > Event Calendar About HPMC OMS Contact Us Directions Event Calendar Hours of Operation How We Compare Job Seekers Notice of Privacy Practices Patient Rights &...

  11. Operations & Maintenance Best Practices - A Guide to Achieving...

    Office of Scientific and Technical Information (OSTI)

    with useful information about O&M management, technologies, energy and water ... met with O&M and Energy managers via Federal Energy Management Program (FEMP) workshops. ...

  12. Research News TEMPLATE

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Revealing Secrets Locked in the Ice page 3 the ENERGY lab NATIONAL ENERGY TECHNOLOGY LABORATORY From NETL's Office of Research & Development - October 2014, Issue 1 Researchnews Science & Engineering To Power Our Future 2 FE AT U RE ST O RY : R e v e a li n g S e c re ts L o c k e d in th e Ic e pa ge 3 Fr om NE TL 's O ffi ce of Re se ar ch & De ve lo pm en t - O ct ob er 20 14 , Iss ue 1 R e s e a r c h n e w s Sc ien ce & En gi ne er in g To Po we r Ou r Fu tu re Contents

  13. Comments on: New report offers best practice for transparent...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    sandia-national-laboratories-report-offers-best-practice-for-transparent-contract-language-of-pv-om-agreements...

  14. Documentation - Laboratory for Laser Energetics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    (S-OM-P-165) S.O. 1-2.2: Type 2 - Non-Propagating (S-OM-P-166) S.O. 1-2.3: Type 3 - A Splitter (S-OM-P-167) S.O. 1-2.4: Type 4 - Terminating in Laser Bay (S-OM-P-168) S.O. 1-2.5: ...

  15. vacate _ 70 FR 48943

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    VII. Agency Contact FOR FURTHER INFORMATION CONTACT: Cosette Ryan, U.S. Department of Education, Graduate Assistance in Areas of National Need Program, 1990 K Street NW., room...

  16. A=14C (70AJ04)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    70AJ04) (See Energy Level Diagrams for 14C) GENERAL: See Table 14.1 [Table of Energy Levels] (in PDF or PS). See (JA54A, EL56B, VI57, BA58E, OT59, SK59, TA60L, WA60, BA61D, FR61B, TA62F, BL63C, NA63A, SO63, VL63A, LI64I, LO64C, BA65T, KO65F, WA65D, ZA65B, BA66PP, BO66J, GU66D, MI66C, ZA66B, GR67M, HA67G, IN67A, KO67C, KO67S, EI68, FA68C, FR68C, NE68A, RO68C, AR69E, AT69, FR69B, SH69, SO69A, SO69D). 1. 14C(β-)14N Qm = 0.156 Recent values are 5745 ± 50 y (MA61B, HU64B), 5780 ± 65 y (WA61E),

  17. Bromocriptine increased operant responding for high fat food but decreased chow intake in both obesity-prone and resistant rats

    SciTech Connect (OSTI)

    Thanos, P.K.; Wang, G.; Thanos, P.K.; Cho, J. Kim, R.; Michaelides, M.; Primeaux, S.; Bray, G.; Wang, G.-J.; Volkow, N.D.

    2010-10-27

    Dopamine (DA) and DAD{sub 2} receptors (D2R) have been implicated in obesity and are thought to be involved in the rewarding properties of food. Osborne-Mendel (OM) rats are susceptible to diet induced obesity (DIO) while S5B/P (S5B) rats are resistant when given a high-fat diet. Here we hypothesized that the two strains would differ in high-fat food self-administration (FSA) and that the D2R agonist bromocriptine (BC) would differently affect their behavior. Ad-libitum fed OM and S5B/P rats were tested in a FSA operant chamber and were trained to lever press for high-fat food pellets under a fixed-ratio (FR1) and a progressive ratio (PR) schedule. After sixteen days of PR sessions, rats were treated with three different doses of BC (1, 10 and 20 mg/kg). No significant differences were found between the two strains in the number of active lever presses. BC treatment (10 mg/kg and 20 mg/kg) increased the number of active lever presses (10 mg/kg having the strongest effect) whereas it decreased rat chow intake in the home cage with equivalent effects in both strains. These effects were not observed on the day of BC administration but on the day following its administration. Our results suggest that these two strains have similar motivation for procuring high fat food using this paradigm. BC increased operant responding for high-fat pellets but decreased chow intake in both strains, suggesting that D2R stimulation may have enhanced the motivational drive to procure the fatty food while correspondingly decreasing the intake of regular food. These findings suggest that susceptibility to dietary obesity (prior to the onset of obesity) may not affect operant motivation for a palatable high fat food and that differential susceptibility to obesity may be related to differential sensitivity to D2R stimulation.

  18. Sandia National Laboratories' Structural Health Monitoring and...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Prognostics Management System Reduces Offshore Wind O&M Costs Sandia National Laboratories' ... (O&M) costs of offshore wind farms between 2 to 5 times the current average ...

  19. Supervisory Electrical Engineer

    Broader source: Energy.gov [DOE]

    This position is located in an Operations and Maintenance (O&M;) District under one of the three Senior O&M; Managers, Transmission Field Services (TF), Transmission Services. Transmission...

  20. Documentation - Laboratory for Laser Energetics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    IR3 High Bandwidth Pulseshape Measurement Setup and Recovery (S-OM-P-129) Unplanned Power Outage Recovery Procedure (S-OM-P-156) Planned Power Outage Shut Down Procedure ...

  1. Supervisory Electronics Engineer

    Broader source: Energy.gov [DOE]

    This position is located in an Operations and Maintenance (O&M;) District under one of the three Senior O&M; Managers, Transmission Field Services (TF), Transmission Services. Transmission...

  2. DOE Announces Webinars on the Buildings of the Future Research...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    the Buildings of the Future Research Project, O&M Best Practices for Small PV Systems, and More DOE Announces Webinars on the Buildings of the Future Research Project, O&M Best ...

  3. Supervisory Electronic Engineer

    Broader source: Energy.gov [DOE]

    This position is located in an Operations and Maintenance (O&M;) District under one of the three Senior O&M; Managers, Transmission Field Services (TF), Transmission Services (T)....

  4. Small- To Medium-Scale Federal Renewable Energy Projects

    Office of Energy Efficiency and Renewable Energy (EERE)

    Operations and maintenance (O&M) measurement tends to focus on reliability as the sole metric. Every Federal agency wants a reliable facility, but this metric alone is not enough to build a successful O&M program.

  5. Enex O M | Open Energy Information

    Open Energy Info (EERE)

    O M Jump to: navigation, search Name: Enex O&M Place: Alphaville - Barueri, Sao Paulo, Brazil Zip: 06454-040 Sector: Hydro Product: Sao Paulo-based O&M service provider, focus on...

  6. Structural Health and Prognostics Management for Offshore Wind Plants; Final Report of Sandia R&D Activities.

    SciTech Connect (OSTI)

    Griffith, Daniel Todd

    2015-04-01

    This final report is a compilation of resear ch efforts - funded by the US Department of Energy Wind and Water Power Technolog ies Office over a four-year period from FY11 through FY14. The goals of this re search program were to develop and evaluate technical innovati ons with promise for maxi mizing revenues and reducing levelized cost of energy (LCOE) for offs hore wind plants - more specifically the goals of the Structural H ealth and Prognostics Management (SHPM) program were to reduce O&M costs and increase energy capture through use of SHPM-based technologies. A technology roadmap was deve loped at the start of the project to guide the research efforts. This roadmap identified and outlined six major research thrust areas each having five stages of ma turity. Research was conducted in each of these thrust areas, as documented throughout this report, although a major focus was on development of damage detection strategi es for the most frequent blade damage conditions and damage mitigation and life-exte nsion strategies via changes in turbine operations (smart loads management). Th e work summarized in this compilation report is the product of the work of many researchers. A summary of the major findings, status of the SHPM Technology Ro admap and recommendations for future work are also provided.

  7. EXHIBIT G

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... Workers include LANS employees, subcontractors, vendors, external organization ... Security Representative OM-MS Occupational Medicine - Medical Services OPSEC Operations ...

  8. Reverse Osmosis Optimization | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Reverse Osmosis Optimization Reverse Osmosis Optimization Report assesses techniques for optimizing reverse osmosis (RO) systems to increase RO system performance and water efficiency. It provides a general description of RO systems, the influence of RO systems on water use, and key areas where RO systems can be optimized to reduce water and energy consumption. This report is intended to help facility managers at Federal sites understand the basic concepts of the RO process and system

  9. Documentation - Laboratory for Laser Energetics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    3 - Beamlines Operator S. O. 3: Beamlines Shot Operation Procedure Index (S-OM-M-014) S. O. 3-1: Beamlines Pre-Operation Procedure (S-OM-P-130) S. O. 3-2: Beamlines Shot Procedures S. O. 3-2-1: Beamlines Operator Type 2 Non-Propagating Shot Procedure (S-OM-P-131) S. O. 3-2-2: Beamlines Operator Type 3 A-Split Shot Procedure (S-OM-P-132) S. O. 3-2-3: Beamlines Operator Type 4-7 Propagating Shot Procedure (S-OM-P-133) S. O. 3-2-4: IR ALT Type 2, 4-7 Propagating Shot Procedure (S-OM-P-134) S. O.

  10. PROJECT PROFILE: Best Practices for Operation and Maintenance of PV and Storage Systems (SuNLaMP)

    Office of Energy Efficiency and Renewable Energy (EERE)

    This project addresses the needs of the rapidly growing photovoltaic (PV) operations and maintenance (O&M) industry to ensure that solar projects are maintained at a high level of consistency and quality. A working group of financial and legal firms, solar developers, O&M service providers, and utilities will contribute to a PV O&M Best Practice document, sharing field data in a performance database and a failure and reliability database. The group will also create a PV O&M Cost Model to estimate costs of delivering a PV O&M program that considers system characteristics and which conditions determine the optimal cleaning and repair schedules for solar projects. This work will enable financial firms to easily categorize, predict, and support solar projects with lower financing costs, which will increase the effectiveness of O&M and the resulting energy delivery and reduce the cost of maintaining PV systems.

  11. Management Homepage | U.S. DOE Office of Science (SC)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Home Management OM Home About Program Direction and Analysis Human Resources Advisory Office Administration Contact Information Management U.S. Department of Energy SC-48/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 More Information » Print Text Size: A A A FeedbackShare Page The Office of Management (OM) is the primary corporate resource for administrative management programs in the Office of Science. OM has responsibility for the development of SC-wide executive policy,

  12. High-Temperature Downhole MWD Tools for Directional Drilling...

    Open Energy Info (EERE)

    Total Project Cost OM-300 - MWD Geothermal Navigation Instrument Washington Honeywell International Inc. Recovery Act: Enhanced Geothermal Systems Component Research and...

  13. Southern Wind Farms Ltd | Open Energy Information

    Open Energy Info (EERE)

    Services Product: Chennai-based firm involved in manufacturing, installation and marketing of WEGs on turnkey basis. Also offers O&M services. References: Southern Wind Farms...

  14. Yerington Paiute Tribe: Building Organizational Capacity for...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    West. pbs.org Political Relations Development Grants Tribal Council Tribal Chairman Enterprises Water Operator Testing Administration O&M Construction Planning Deputy ...

  15. How to Determine and Verify Operating and Maintenance Savings in Federal Energy Savings Performance Contracts

    Broader source: Energy.gov [DOE]

    Document describes guidance on operations and maintenance (O&M) savings determination and verification within the energy savings performance contracts (ESPCs).

  16. Guide to Operating and Maintaining EnergySmart Schools

    SciTech Connect (OSTI)

    2009-06-01

    This guide is a primary resource for developing and implementing a district- or school- wide operations and maintenance (O&M) program that focuses on energy efficiency.

  17. Documentation - Laboratory for Laser Energetics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    5 - Optomechanical Front Matter - Maintenance Index & Schedules (S-OM-P-030) Subsystem ... HEDVAC Procedures HEDVAC System Maintenance (S-SM-P-331) HEDVAC Pump Maintenance ...

  18. AWEA Wind Project Operations and Maintenance and Safety Seminar

    Broader source: Energy.gov [DOE]

    The AWEA Wind Project O&M and Safety Seminar is designed for owners, operators, turbine manufactures, material suppliers, wind technicians, managers, supervisors, engineers, and occupational...

  19. Building Actionable Climate Action Plans | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Utilities to Deliver Energy Efficiency Programs Effective O&M Policy in Public Buildings Procuring and Implementing Solar Projects on Public Buildings: How to Avoid Common ...

  20. Property:OutageMapURL | Open Energy Information

    Open Energy Info (EERE)

    + Agralite Electric Coop + https:pyxis-oms.comOutageMapAgraliteOutageMap.html + Alfalfa Electric Coop, Inc + https:ebill.alfalfaelectric.comwoViewermapviewer.html?config...

  1. Guide to Operating and Maintaining EnergySmart Schools

    Broader source: Energy.gov [DOE]

    This guide is a primary resource for developing and implementing a district- or school- wide operations and maintenance (O&M) program that focuses on energy efficiency.

  2. Federal Energy Management Program Organization Chart

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Affairs, Technology Deployment Nicolas Baker FEMP Website Joe Konrade Budget Peter Murphy O&M, Energy Security Cyrus Nasseri Interagency Coordination, Data Management Chris Tremper...

  3. NNMI Industry Day: Smart Manufacturing AMO Overview

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Climate Action Plan: Efficiency and Sustainability National Economic Council: ... O&M High Fidelity Modelling X X X Data Architecture & Platform X X X Sensor Development & ...

  4. Step 4: Project Implementation

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... expected * Technology O&M Assumed low, mitigable or allocatable Sources: Adapted from Holland & Hart, RE Project Development & Finance & Infocast, Advanced RE Project Finance & ...

  5. The Western Wind and Solar Integration Study Phase 2: Executive...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... O&M operations and maintenance PPA power purchase agreement PV photovoltaic ReEDS Regional Energy Deployment System SO 2 sulfur dioxide ST steam turbine TEPPC Transmission ...

  6. BPA-2010-01614-FOIA Correspondence

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    with the FOIA. Mr. Chris Nielsen, Contract Administrator, Capitol & O&M Services and Purchasing, has been assigned as the Authorizing Official for your request. Mr. Nielsen...

  7. BPA-2010-01613-FOIA Correspondence

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    with the FOIA. Mr. Chris Nielsen, Contract Administrator, Capitol & O&M Services and Purchasing, has been assigned as the Authorizing Official for your request. Mr. Nielsen...

  8. EA-1697: Finding of No Significant Impact | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    area includes portions of San Joaquin, Contra Costa, Alameda, Calaveras, Tuolumne, Santa Clara, and Merced counties. Proposed O&M activities include, but are not limited to,...

  9. Patriot Solar Group | Open Energy Information

    Open Energy Info (EERE)

    energy industry, Solar power plants construction and commissioning, Operating and maintenance (O&M) - Renewable energy Product: MOUNTING SYSTEMS, EPC, INSTALLATIONS Number of...

  10. Wind Turbine Condition Monitoring, Reliability Database, and...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Wind Turbine Gearbox Reliability Database, Condition Monitoring, and O&M Research Update ... (OEMs), gearbox rebuild shops, wind plant owneroperators, and consulting ...

  11. Operations & Maintenance Best Practices Guide: Release 3.0

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    process begins during the planning stages of a new building ... staff with operating problems in place, incomplete ... improved indoor air quality, and fewer O&M emergency calls. ...

  12. EERE PowerPoint 97-2004 Template: Green Version

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Project Completed - 2 years of operational data for plant output and O&M * Electratherm: air-cooled binary unit using fluid from mining operation - Project Completed - ...

  13. Operations and Maintenance Best Practices--A Guide to Achieving...

    Office of Scientific and Technical Information (OSTI)

    This guide is designed to serve as a source for O&M management and technical staff. It ... OPERATION; EFFICIENCY; MAINTENANCE; MANAGEMENT; RECOMMENDATIONS Word Cloud More Like ...

  14. Operations & Maintenance Best Practices - A Guide to Achieving...

    Office of Scientific and Technical Information (OSTI)

    This guide highlights operations and maintenance programs targeting energy and water ... O&M management, technologies, energy and water efficiency, and cost-reduction approaches. ...

  15. Modeling and Analysis of Wholesale Electricity Market Design...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... NREL National Renewable Energy Laboratory O&M operations and maintenance VG variable generation iv This report is ... through their planning Web site. 2 It included generation and ...

  16. Microsoft Word - Understanding Smart Grid Benefits_final.docx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... O&M processes Improved load forecasting enabling more accurate predictions on ... enable delivery companies to keep their costs of service down, resulting in less need to ...

  17. Challenge # 2 Logistics and Compatibility with Existing Infrastructure...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Transport distance Capital and O&M Speed Fuel consumption Capacity Load factor Product weight Transfer time & costs Product volume Storage & Use Above ground tanks Underground ...

  18. Energy Efficiency Financing Program Implementation Primer

    SciTech Connect (OSTI)

    Financing Solutions Working Group

    2014-01-01

    Provides key considerations for policymakers, energy efficiency program administrators, and program partners om implementing successful energy efficiency financing programs for existing buildings.

  19. Documentation - Laboratory for Laser Energetics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    OMEGA Target Bay 10-Ton Overhead Crane Operating Procedure (S-OM-P-187) Comments Address document comments, questions and corrections to the OMEGA Associate Laser Facility Manager. ...

  20. Sandia Energy - Sandia R&D Funded under New DOE SunShot Program

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    statistical reliability and extending unit lifetime are critically important to a large solar installation's O&M scheme. Failures in other PE applications are primarily due to...

  1. Microsoft Word - 341-03-03_QGESS_RF_Rev2_20130828.docx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    I&C Instrumentation and control ID Induced draft HGCU Hot gas cleanup HRSG Heat recovery steam generator NETL National Energy Technology Laboratory O&M Operation and...

  2. Reduce Operating Costs with an EnergySmart School Project

    Broader source: Energy.gov [DOE]

    EnergySmart Schools fact sheet on how school operations and maintenance (O&M) personnel can play a greater role in managing ever-increasing energy costs.

  3. Microsoft Word - ViArray_Fact_ Sheet_SAND2011-3935P_updated_format...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    decoupling ude: & Control tion itoring Parts & FPG vironment op ility System boratories ha pplications. services" wi me custom ra aging, test, fa om microele Hard S tructured Ap...

  4. BONNEVILLE POWER ADMINISTRATION

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    O&M Costs (Column AZ) Present Value of Periodic Capital Replacement Cost (Column BA) Power System Transmission System Coincident Factor (Column BB) Distribution System...

  5. Pueblo of Laguna Utility Authority

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    PAYMENT ASSISTANCE PROGRAM (TRIBAL FUNDED) * NATIVE COMMUNITY FINANCE THINGS TO KEEP IN MIND * COST OF SERVICE * O&M MANUALS - INFRASTRUCTURE * STRATEGIC PLANNING (HAVE YOUR ...

  6. MDM Tech Day Presentation | Department of Energy

    Energy Savers [EERE]

    MDM Tech Day Presentation MDM Tech Day Presentation More Documents & Publications Slide 1 Microsoft Word - MRContingencyProtocolEMFINAL.docx UPF R&OM Management...

  7. Human Resources Advisory Office | U.S. DOE Office of Science...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Human Resources Advisory Office Management OM Home About Program Direction and Analysis Human Resources Advisory Office Administration Contact Information Management U.S. ...

  8. Finding of No Significant Impact and Final Environmental Assessment...

    Office of Environmental Management (EM)

    ... per square inch gauge SO2 sulfur dioxide SOx sulfur ... (O&M) costs; (4) reducing construction and start-up ... Adequate containment methods shall be employed during ...

  9. Energisa Solu es | Open Energy Information

    Open Energy Info (EERE)

    Gerais, Brazil Sector: Hydro Product: Brazilian based small hydro project developer and O&M service provider. References: Energisa Solues1 This article is a stub. You...

  10. Fluor Corp | Open Energy Information

    Open Energy Info (EERE)

    75039 Product: US provider of engineering, procurement, construction management (EPCM), O&M, and project management. Coordinates: 32.813516, -96.955506 Show Map Loading...

  11. IPE Energy | Open Energy Information

    Open Energy Info (EERE)

    Services Product: Sao Paulo-based hydro turbine and components, builderengineering and O&M services provider company. Focus on small hydro sector. References: IPE Energy1 This...

  12. CLP Envirogas Ltd | Open Energy Information

    Open Energy Info (EERE)

    Envirogas Ltd Place: Bolton, England, United Kingdom Zip: BL1 4AY Product: Development, O&M and management of landfill gas fuelled power generation projects. References: CLP...

  13. GreenBrilliance | Open Energy Information

    Open Energy Info (EERE)

    Services Product: US-based manufacturer of PV modules; also provides installation and O&M services. Coordinates: 37.505366, -81.341159 Show Map Loading map......

  14. B O N N E V I L L E P O W E R A D M I N I S T R A T I O N

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    These may include water savings, or gas savings. Annual Operations and Maintenance (O&M) Cost Change (cost savings is negative) J Estimated (Proposal) year This column is...

  15. IDESA SA | Open Energy Information

    Open Energy Info (EERE)

    Spanish project developer that does its own promotion, engineering, installation and O&M for PV systems. Coordinates: 37.387697, -6.001813 Show Map Loading map......

  16. FF CADDCAP_FR1.book

    National Nuclear Security Administration (NNSA)

    contamination are not cost effective. Second, because of the high remediation costs, closure in place with monitoring and institutional controls is the only likely...

  17. Quantification of Organic Porosity and Water Accessibility in Marcellus Shale Using Neutron Scattering

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Gu, Xin; Mildner, David F. R.; Cole, David R.; Rother, Gernot; Slingerland, Rudy; Brantley, Susan L.

    2016-04-28

    Pores within organic matter (OM) are a significant contributor to the total pore system in gas shales. These pores contribute most of the storage capacity in gas shales. Here we present a novel approach to characterize the OM pore structure (including the porosity, specific surface area, pore size distribution, and water accessibility) in Marcellus shale. By using ultrasmall and small-angle neutron scattering, and by exploiting the contrast matching of the shale matrix with suitable mixtures of deuterated and protonated water, both total and water-accessible porosity were measured on centimeter-sized samples from two boreholes from the nanometer to micrometer scale withmore » good statistical coverage. Samples were also measured after combustion at 450 °C. Analysis of scattering data from these procedures allowed quantification of OM porosity and water accessibility. OM hosts 24–47% of the total porosity for both organic-rich and -poor samples. This porosity occupies as much as 29% of the OM volume. In contrast to the current paradigm in the literature that OM porosity is organophilic and therefore not likely to contain water, our results demonstrate that OM pores with widths >20 nm exhibit the characteristics of water accessibility. In conclusion, our approach reveals the complex structure and wetting behavior of the OM porosity at scales that are hard to interrogate using other techniques.« less

  18. NSRD-06. Computational Capability to Substantiate DOE-HDBK-3010 Data

    SciTech Connect (OSTI)

    Louie, David L.Y.; Brown, Alexander L.

    2015-12-01

    Safety basis analysts throughout the U.S. Department of Energy (DOE) complex rely heavily on the information provided in the DOE Hand book, DOE-HDBK-3010, Airborne Release Fractions/Rates and Resp irable Fractions for Nonreactor Nuclear Facilities , to determine source terms. In calcula ting source terms, analysts tend to use the DOE Handbook's bounding values on airbor ne release fractions (ARFs) and respirable fractions (RFs) for various cat egories of insults (representing potential accident release categories). This is typica lly due to both time constraints and the avoidance of regulatory critique. Unfort unately, these bounding ARFs/RFs represent extremely conservative values. Moreover, th ey were derived from very limited small- scale table-top and bench/labo ratory experiments and/or fr om engineered judgment. Thus the basis for the data may not be re presentative to the actual unique accident conditions and configura tions being evaluated. The goal of this res earch is to develop a more ac curate method to identify bounding values for the DOE Handbook using the st ate-of-art multi-physics-based high performance computer codes. This enable s us to better understand the fundamental physics and phenomena associated with the ty pes of accidents for the data described in it. This research has examined two of the DOE Handbook's liquid fire experiments to substantiate the airborne release frac tion data. We found th at additional physical phenomena (i.e., resuspension) need to be included to derive bounding values. For the specific cases of solid powder under pre ssurized condition and mechanical insult conditions the codes demonstrated that we can simulate the phenomena. This work thus provides a low-cost method to establis h physics-justified sa fety bounds by taking into account specific geometri es and conditions that may not have been previously measured and/or are too costly to do so.

  19. Emergence of Integrated Urology-Radiation Oncology Practices in the State of Texas

    SciTech Connect (OSTI)

    Jhaveri, Pavan M. [Section of Radiation Oncology, Department of Radiology, Baylor College of Medicine, Houston, Texas (United States)] [Section of Radiation Oncology, Department of Radiology, Baylor College of Medicine, Houston, Texas (United States); Sun Zhuyi [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States)] [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Ballas, Leslie [Valley Radiotherapy Associates Medical Group, Manhattan Beach, California (United States)] [Valley Radiotherapy Associates Medical Group, Manhattan Beach, California (United States); Followill, David S. [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas (United States)] [Department of Radiation Physics, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Hoffman, Karen E. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States)] [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Jiang Jing [Division of Quantitative Sciences, University of Texas MD Anderson Cancer Center, Houston, Texas (United States)] [Division of Quantitative Sciences, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Smith, Benjamin D., E-mail: BSmith3@mdanderson.org [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2012-09-01

    Purpose: Integrated urology-radiation oncology (RO) practices have been advocated as a means to improve community-based prostate cancer care by joining urologic and radiation care in a single-practice environment. However, little is known regarding the scope and actual physical integration of such practices. We sought to characterize the emergence of such practices in Texas, their extent of physical integration, and their potential effect on patient travel times for radiation therapy. Methods and Materials: A telephone survey identified integrated urology-RO practices, defined as practices owned by urologists that offer RO services. Geographic information software was used to determine the proximity of integrated urology-RO clinic sites with respect to the state's population. We calculated patient travel time and distance from each integrated urology-RO clinic offering urologic services to the RO treatment facility owned by the integrated practice and to the nearest nonintegrated (independent) RO facility. We compared these times and distances using the Wilcoxon-Mann-Whitney test. Results: Of 229 urology practices identified, 12 (5%) offered integrated RO services, and 182 (28%) of 640 Texas urologists worked in such practices. Approximately 53% of the state population resides within 10 miles of an integrated urology-RO clinic site. Patients with a diagnosis of prostate cancer at an integrated urology-RO clinic site travel a mean of 19.7 miles (26.1 min) from the clinic to reach the RO facility owned by the integrated urology-RO practice vs 5.9 miles (9.2 min) to reach the nearest nonintegrated RO facility (P<.001). Conclusions: Integrated urology-RO practices are common in Texas and are generally clustered in urban areas. In most integrated practices, the urology clinics and the integrated RO facilities are not at the same location, and driving times and distances from the clinic to the integrated RO facility exceed those from the clinic to the nearest

  20. DRAFT HAB Advice: Remedial Investigation/Feasibility Study and...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    HAB Advice: Remedial InvestigationFeasibility Study and Proposed Plan for the 100-FR-1, 100-FR-2, 100-FR-3, 100-IU-2 and 100-IU-6 Operable Units; DOERL Authors; Shelley Cimon,...

  1. Final Report on the Operation and Maintenance Improvement Program for Concentrating Solar Power Plants

    SciTech Connect (OSTI)

    Cohen Gilbert E.; Kearney, David W.; Kolb, Gregory J.

    1999-06-01

    This report describes the results of a six-year, $6.3 million project to reduce operation and maintenance (O&M) costs at power plants employing concentrating solar power (CSP) technology. Sandia National Laboratories teamed with KJC Operating Company to implement the O&M Improvement Program. O&M technologies developed during the course of the program were demonstrated at the 150-MW Kramer Junction solar power park located in Boron, California. Improvements were made in the following areas: (a) efficiency of solar energy collection, (b) O&M information management, (c) reliability of solar field flow loop hardware, (d) plant operating strategy, and (e) cost reduction associated with environmental issues. A 37% reduction in annual O&M costs was achieved. Based on the lessons learned, an optimum solar- field O&M plan for future CSP plants is presented. Parabolic trough solar technology is employed at Kramer Junction. However, many of the O&M improvements described in the report are also applicable to CSP plants based on solar power tower or dish/engine concepts.

  2. Carbon Mineralizability Determines Interactive Effects on Mineralization of Pyrogenic Organic Matter and Soil Organic Carbon

    SciTech Connect (OSTI)

    Whitman, Thea L.; Zhu, Zihua; Lehmann, Johannes C.

    2014-10-31

    Soil organic carbon (SOC) is a critical and active pool in the global C cycle, and the addition of pyrogenic organic matter (PyOM) has been shown to change SOC cycling, increasing or decreasing mineralization rates (often referred to as priming). We adjusted the amount of easily mineralizable C in the soil, through 1-day and 6-month pre-incubations, and in PyOM made from maple wood at 350°C, through extraction. We investigated the impact of these adjustments on C mineralization interactions, excluding pH and nutrient effects and minimizing physical effects. We found short-term increases (+20-30%) in SOC mineralization with PyOM additions in the soil pre-incubated for 6 months. Over the longer term, both the 6-month and 1-day pre-incubated soils experienced net ~10% decreases in SOC mineralization with PyOM additions. This was possibly due to stabilization of SOC on PyOM surfaces, suggested by nanoscale secondary ion mass spectrometry. Additionally, the duration of pre-incubation affected priming interactions, indicating that there may be no optimal pre-incubation time for SOC mineralization studies. We show conclusively that relative mineralizability of SOC in relation to PyOM-24 C is an important determinant of the effect of PyOM additions on SOC mineralization.

  3. Federal Energy Management Program Report Template

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Typical applications of RO technology are seawater desalination, boiler feed water filtering, product rinsing, microelectronics production, laboratory testing, biotechnology, and ...

  4. X-ray emission spectroscopy of bulk liquid water in "no-man's...

    Office of Scientific and Technical Information (OSTI)

    Radiation Research, Helmholtz-Zentrum Berlin fr Materialien und Energie GmbH, Albert-Einstein-Strae 15, 12489 Berlin, Germany, Institut fr Physik und Astronomie,...

  5. DOE Orders Self-Study Program - DOE-STD-1063-2011, Facility Representa...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    key personnel. In the second section, the requirements of the FR program are discussed. The third section covers the three appendices of this standard: FR performance indicators...

  6. EIS-0517: FERC Notice of Intent to Prepare an Environmental Impact...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Statement (FR) EIS-0517: FERC Notice of Intent to Prepare an Environmental Impact Statement (FR) Port Arthur Liquefaction Project and Port Arthur Pipeline Project; Jefferson and ...

  7. Browse by Discipline -- E-print Network Subject Pathways: Computer...

    Office of Scientific and Technical Information (OSTI)

    ... Tibor (Tibor Katrinak) - Department of Algebra, Geometry and Didactics of Mathematics, ... Andreas (Andreas Kirsch) - Institut fr Algebra und Geometrie & Fakultt fr ...

  8. Integrating oil movement and data systems beefs project benefits

    SciTech Connect (OSTI)

    King, M. )

    1993-04-12

    Automatic data reconciliation, yield reconciliation, and refinery information systems are important considerations in automating refinery oil movement and storage (OM and S) systems. A number of practical examples will demonstrate the importance of integrating these information systems as opposed to using a stand alone OM and S system. Also important in implementing an integrated, automated OM and S scheme are the necessary changes in work functions and habits that will accompany the new system. The paper describes data reconciliation; oil loss; maintenance/inspection; taxes/claims; yield reconciliation; cost reduction; integration; make or purchase decision; and organizational impact.

  9. Sandia Energy Solar

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    New report offers best practice for transparent contract language of PV O&M agreements http:energy.sandia.govnew-sandia-national-laboratories-report-offers-best-practice-for-tra...

  10. Articles about Next-Generation Technologies

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    is that most projections put the operation and maintenance (O&M) costs of offshore wind farms between 2 to 5 times the current average costs for land-based wind farms. One way...

  11. Articles about Manufacturing

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    is that most projections put the operation and maintenance (O&M) costs of offshore wind farms between 2 to 5 times the current average costs for land-based wind farms. One way...

  12. Sandia Energy Tara Camacho-Lopez

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ct-language-of-pv-om-agreementsfeed 0 Energy Across America: A Policy Discussion on Microgrid Technology http:energy.sandia.govenergy-across-america-a-policy-discussion-on-mic...

  13. Sandia Energy News & Events

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ct-language-of-pv-om-agreementsfeed 0 Energy Across America: A Policy Discussion on Microgrid Technology http:energy.sandia.govenergy-across-america-a-policy-discussion-on-mic...

  14. Sandia Energy News

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ct-language-of-pv-om-agreementsfeed 0 Energy Across America: A Policy Discussion on Microgrid Technology http:energy.sandia.govenergy-across-america-a-policy-discussion-on-mic...

  15. User:Rentechno | Open Energy Information

    Open Energy Info (EERE)

    the object, calculate the expected power and so on. Operating and maintenance (O&M) - Renewable energy It is no secret that the maintenance of solar power plants, as well as...

  16. Federal Utility Partnership Working Group (FUPWG) Meeting Report...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    When a site uses appropriations for a project, Ms. Shah recommends having an O&M contract, to ensure that the project is producing electricity for the life of the...

  17. FEMP Offers New Training on Photovoltaic Operations and Maintenance Best Practices

    Broader source: Energy.gov [DOE]

    FEMP will present O&M Best Practices for Small Scale PV Systems, a live First Thursday Seminar on December 4, 2014, from 1:30 p.m. to 3 p.m.

  18. Articles about Manufacturing | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    is that most projections put the operation and maintenance (O&M) costs of offshore wind farms between 2 to 5 times the current average costs for land-based wind farms. One way...

  19. FEMP Focus - Spring 2004

    SciTech Connect (OSTI)

    2004-04-29

    Features information about Measurement and Verification (M&V) of Energy Savings, Energy Rate Escalation calculator, Landfill Gas-to-Energy Project, Natural Gas Markets, GSA develops new O&M contract, and more for federal agencies.

  20. Q

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Department of Energy Bo nneville Power Administration P.O. Box 3621 Portland, Oregon 97208-3621 FREE I I )OM OF INFORMATION ACTPRIVACY PROGRAM March 19, 2014 In reply refer to:...

  1. New Course Teaches Best Practices for Water Management for Federal Facilities

    Broader source: Energy.gov [DOE]

    FEMP now offers Best Practices for Comprehensive Water Management for Federal Facilities, a new e-Training core course providing skills to increase efficiency and reduce water use through O&M practices and water-efficient technologies.

  2. CX-014464: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Replacement of Bayou Choctaw Deep Well Anode Ground Bed Sites (BC-OM-1472) CX(s) Applied: B1.3Date: 12/08/2015 Location(s): Multiple LocationsOffices(s): Strategic Petroleum Reserve Field Office

  3. Meeker Coop Light & Power Assn | Open Energy Information

    Open Energy Info (EERE)

    erative-Light-Power-Assoc400233190021573 Outage Hotline: 800.232.6257 Outage Map: pyxis-oms.comOutageMapMeeker References: EIA Form EIA-861 Final Data File for 2010 - File1a1...

  4. Agralite Electric Coop | Open Energy Information

    Open Energy Info (EERE)

    gralite-Electric-Cooperative144866998510 Outage Hotline: 888-884-3887 Outage Map: pyxis-oms.comOutageMapAgrali References: EIA Form EIA-861 Final Data File for 2010 - File1a1...

  5. Coastal Electric Member Corp | Open Energy Information

    Open Energy Info (EERE)

    Website: www.coastalelectriccooperative Outage Hotline: 1-800-421-2343 Outage Map: oms.coastalemc.comOMSWebMapM References: EIA Form EIA-861 Final Data File for 2010 -...

  6. Hancock-Wood Electric Coop Inc | Open Energy Information

    Open Energy Info (EERE)

    www.facebook.comhwe.coop Outage Hotline: 800-445-4840 or 888-417-3010 Outage Map: oms.hwe.coop References: EIA Form EIA-861 Final Data File for 2010 - File1a1 EIA Form...

  7. Tri-County Electric Coop, Inc (Texas) | Open Energy Information

    Open Energy Info (EERE)

    Azle, TX Zip: 76020 Phone Number: 817-444-3201 Outage Hotline: 817-444-3201 Outage Map: oms.tcectexas.com References: EIA Form EIA-861 Final Data File for 2010 - File1a1 EIA...

  8. Batliboi enXco Pvt Ltd | Open Energy Information

    Open Energy Info (EERE)

    search Name: Batliboi enXco Pvt Ltd Place: Chennai, India Zip: 600 014 Sector: Wind energy Product: Chennai-based wind project developer and O&M provider. JV between enXco...

  9. U.S. Energy Information Administration (EIA) - Source

    Gasoline and Diesel Fuel Update (EIA)

    The importance of the factors varies among the technologies. For technologies such as solar and wind generation that have no fuel costs and relatively small variable O&M costs,...

  10. Levelized cost and levelized avoided cost of new generation resources...

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    3 The importance of the factors varies among the technologies. For technologies such as solar and wind generation that have no fuel costs and relatively small variable O&M costs,...

  11. Presentation title: This can be up to 2 lines

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    ... Plant "nth" plant Pyrolysis Gasification Green Diesel Feedstock O&M Capital Drop-in ... in the AEO March 20, 2013 Macro Economy Energy Demand Primary Energy Supply Energy ...

  12. Budgeting for Solar PV Plant Operations & Maintenance: Practices and Pricing.

    SciTech Connect (OSTI)

    Enbar, Nadav; Weng, Dean; Klise, Geoffrey Taylor

    2015-12-01

    With rising grid interconnections of solar photovoltaic (PV) systems, greater attention is being trained on lifecycle performance, reliability, and project economics. Expected to meet production thresholds over a 20-30 year timeframe, PV plants require a steady diet of operations and maintenance (O&M) oversight to meet contractual terms. However, industry best practices are only just beginning to emerge, and O&M budgets—given the arrangement of the solar project value chain—appear to vary widely. Based on insights from in-depth interviews and survey research, this paper presents an overview of the utility-scale PV O&M budgeting process along with guiding rationales, before detailing perspectives on current plant upkeep activities and price points largely in the U.S. It concludes by pondering potential opportunities for improving upon existing O&M budgeting approaches in ways that can benefi t the industry at-large.

  13. Budgeting for Solar PV Plant Operations & Maintenance: Practices and Pricing.

    SciTech Connect (OSTI)

    Enbar, Nadav; Weng, Dean; Klise, Geoffrey Taylor

    2016-01-01

    With rising grid interconnections of solar photovoltaic (PV) systems, greater attention is being trained on lifecycle performance, reliability, and project economics. Expected to meet production thresholds over a 20-30 year timeframe, PV plants require a steady diet of operations and maintenance (O&M) oversight to meet contractual terms. However, industry best practices are only just beginning to emerge, and O&M budgets—given the arrangement of the solar project value chain—appear to vary widely. Based on insights from in-depth interviews and survey research, this paper presents an overview of the utility-scale PV O&M budgeting process along with guiding rationales, before detailing perspectives on current plant upkeep activities and price points largely in the U.S. It concludes by pondering potential opportunities for improving upon existing O&M budgeting approaches in ways that can benefit the industry at-large.

  14. Stretch/Reach Codes | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Transcript PDF icon Presentation More Documents & Publications Green Codes and Programs Low-to-No Cost Strategy for Energy Efficiency in Public Buildings Effective O&M Policy in ...

  15. Guide to Operating and Maintaining EnergySmart Schools

    Broader source: Energy.gov (indexed) [DOE]

    a district- or school-wide operations and maintenance (O&M) program that focuses on energy efficiency. The EnergySmart Schools Solutions companion CD contains additional sup-...

  16. New report offers best practice for transparent contract language...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... Twitter Google + Vimeo Newsletter Signup SlideShare New report offers best practice for transparent contract language of PV O&M agreements HomeNews, News & Events, SolarNew ...

  17. SANDIA REPORT SAND2014-9040 Unlimited Release

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... R&D is needed in the area of real-time-forecasting and improving advanced control systems. ... there remains large uncertainty in array costs covered under the M&D, O&M, and EC modules ...

  18. Documentation - Laboratory for Laser Energetics

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    4 - Laser Drivers Index S.O. 4: Laser Drivers Shot Operation Procedure Index (S-OM-M-015) LDO Shot Preparation Checklists S.O. 4-1: Laser Drivers Operator's Shot Preparation ...

  19. Sandia Corporate Overview - Core group

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Market instability > players come and go DOE goal: Pull-in earlier Current operators care about capital utilization more than "new technology" - Strong need to reduce O&M...

  20. CX-012336: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Replace West Hackberry Ported Coax at Northwest Perimeter (WH-OM-1194) CX(s) Applied: B1.7 Date: 06/09/2014 Location(s): Louisiana Offices(s): Strategic Petroleum Reserve Field Office

  1. Ligand-gated Diffusion Across the Bacterial Outer Membrane

    SciTech Connect (OSTI)

    B Lepore; M Indic; H Pham; E Hearn; D Patel; B van den Berg

    2011-12-31

    Ligand-gated channels, in which a substrate transport pathway is formed as a result of the binding of a small-molecule chemical messenger, constitute a diverse class of membrane proteins with important functions in prokaryotic and eukaryotic organisms. Despite their widespread nature, no ligand-gated channels have yet been found within the outer membrane (OM) of Gram-negative bacteria. Here we show, using in vivo transport assays, intrinsic tryptophan fluorescence and X-ray crystallography, that high-affinity (submicromolar) substrate binding to the OM long-chain fatty acid transporter FadL from Escherichia coli causes conformational changes in the N terminus that open up a channel for substrate diffusion. The OM long-chain fatty acid transporter FadL from E. coli is a unique paradigm for OM diffusion-driven transport, in which ligand gating within a {beta}-barrel membrane protein is a prerequisite for channel formation.

  2. November 16, 2005 Letter from Paul Norman to Customers

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    O&M: The costs of the Federal hydro system compare well in North American hydro benchmarking studies. However, as suggested by customers during the Power Function Review, we...

  3. 2013 Distributed Wind Market Report

    Broader source: Energy.gov (indexed) [DOE]

    ... the costs of the generatoralternator, blades, ... greater than 1 MW. These O&M cost ranges ... no-storage wind-diesel system on St. Paul Island in the 1990s to provide power ...

  4. CX-013489: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Maintenance Clean the Big Hill Raw Water Intake Structure Pump Bay (GH-OM-1167) CX(s) Applied: B1.3Date: 02/23/2015 Location(s): TexasOffices(s): Strategic Petroleum Reserve Field Office

  5. Oman: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    Country Profile Name Oman Population 2,773,479 GDP 78,788,000,000 Energy Consumption 0.71 Quadrillion Btu 2-letter ISO code OM 3-letter ISO code OMN Numeric ISO...

  6. Contact Us | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Contact Us Occupational Medicine: 515-294-2056 G11 Technical Administrative Services Facility (TASF) om@ameslab.gov Tell us how we may improve services to you. We value your opinion

  7. B9 Energy O M Ltd | Open Energy Information

    Open Energy Info (EERE)

    O M Ltd Jump to: navigation, search Name: B9 Energy (O&M) Ltd Place: Larne, United Kingdom Zip: BT40 2SF Sector: Services, Wind energy Product: Operates and maintains wind farms...

  8. FBA Franco Brasileira SA | Open Energy Information

    Open Energy Info (EERE)

    search Name: FBA Franco Brasileira SA Place: Sao Paulo, Brazil Product: Brazil based O&M service provider. References: FBA Franco Brasileira SA1 This article is a stub. You...

  9. Lars Enviro | Open Energy Information

    Open Energy Info (EERE)

    Nagpur, India Zip: 440 010 Sector: Biomass Product: Nagpur-based biomass equipment and O&M provider. Coordinates: 26.93874, 83.20292 Show Map Loading map......

  10. Reverse Osmosis Optimization

    SciTech Connect (OSTI)

    2013-08-01

    This technology evaluation was prepared by Pacific Northwest National Laboratory on behalf of the U.S. Department of Energy’s Federal Energy Management Program (FEMP). The technology evaluation assesses techniques for optimizing reverse osmosis (RO) systems to increase RO system performance and water efficiency. This evaluation provides a general description of RO systems, the influence of RO systems on water use, and key areas where RO systems can be optimized to reduce water and energy consumption. The evaluation is intended to help facility managers at Federal sites understand the basic concepts of the RO process and system optimization options, enabling them to make informed decisions during the system design process for either new projects or recommissioning of existing equipment. This evaluation is focused on commercial-sized RO systems generally treating more than 80 gallons per hour.

  11. Reverse Osmosis Optimization

    SciTech Connect (OSTI)

    McMordie Stoughton, Kate; Duan, Xiaoli; Wendel, Emily M.

    2013-08-26

    This technology evaluation was prepared by Pacific Northwest National Laboratory on behalf of the U.S. Department of Energy’s Federal Energy Management Program (FEMP). ¬The technology evaluation assesses techniques for optimizing reverse osmosis (RO) systems to increase RO system performance and water efficiency. This evaluation provides a general description of RO systems, the influence of RO systems on water use, and key areas where RO systems can be optimized to reduce water and energy consumption. The evaluation is intended to help facility managers at Federal sites understand the basic concepts of the RO process and system optimization options, enabling them to make informed decisions during the system design process for either new projects or recommissioning of existing equipment. This evaluation is focused on commercial-sized RO systems generally treating more than 80 gallons per hour.¬

  12. About | U.S. DOE Office of Science (SC)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    About Management OM Home About Organization Chart .pdf file (40KB) Director Biography Staff Jobs Program Direction and Analysis Human Resources Advisory Office Administration Contact Information Management U.S. Department of Energy SC-48/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 More Information » About Print Text Size: A A A FeedbackShare Page The Office of Management (OM) serves as the primary corporate resource for administrative management in the Office of Science

  13. Highly Selective Adsorption of Ethylene over Ethane in a MOF Featuring the Combination of Open Metal Site and -Complexation

    SciTech Connect (OSTI)

    Zhang, Yiming; LI, Baiyan; Wu, Zili; Ma, Shengqian

    2015-01-01

    The introduction of the combination of open metal site (OMS) and -complexation into MOF has led to very high ethylene/ethane adsorption selectivity at 318K, as illustrated in the context of MIL-101-Cr-SO3Ag. The interactions with ethylene from both OMS and -complexation in MIL-101-Cr-SO3Ag have been investigated by in situ IR spectroscopic studies and computational calculations, which suggest -complexation contributes dominantly to the high ethylene/ethane adsorption selectivity.

  14. Exposure Evaluation Process

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Exposure Evaluation Process for Tank Farm Workers L.B. Sandy Rock, MD, MPH Risk Communication HPMC Occupational Medical Services An increase in the number of tank farm vapor exposures has led to many questions and concerns among workers and management. * During regular clinic hours, HPMC OMS is responsible for the medical evaluation of workers reporting exposure to vapors. * At other times, workers are taken to Kadlec Hospital which has an arrangement with DOE/HPMC OMS to evaluate, treat, refer

  15. MxMn8O16 (M = Ag or K) as promising cathode materials for secondary Mg based batteries: The role of the cation M

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Huang, Jianping; Takeuchi, Esther S.; Altug S. Poyraz; Takeuchi, Kenneth J.; Marschilok, Amy C.

    2016-02-15

    Here, AgxMn8O16 (Ag-OMS-2) and KxMn8O16 (K-OMS-2) were investigated as high voltage cathode materials for Mg based batteries. Both MxMn8O16 materials delivered high initial capacities (>180 mA h g–1), and KxMn8O16 showed high cycle stability with a reversible capacity of >170 mA h g–1 after 20 cycles.

  16. Highly Selective Adsorption of Ethylene over Ethane in a MOF Featuring the Combination of Open Metal Site and -Complexation

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Zhang, Yiming; Li, Baiyan; Wu, Zili; Ma, Shengqian

    2015-01-09

    The introduction of the combination of open metal site (OMS) and -complexation into MOF has led to very high ethylene/ethane adsorption selectivity at 318K, as illustrated in the context of MIL-101-Cr-SO3Ag. The interactions with ethylene from both OMS and -complexation in MIL-101-Cr-SO3Ag have been investigated by in situ IR spectroscopic studies and computational calculations, which suggest -complexation contributes dominantly to the high ethylene/ethane adsorption selectivity.

  17. Greg's Memo

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    http://www.cfo.doe.gov/progliaison/2005fr.pdf

  18. Corrections Notice, Federal Register, 71 FR 10097, February 28...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Document displays a correction notice pertaining to Energy Conservation Standards for New Federal Commercial and Multi-Family High-Rise Residential Buildings and New Federal ...

  19. TO: FILE MEMORANDUM FR0t-k

    Office of Legacy Management (LM)

    ... "Notification of Hazardous Haste Site" forms ,for our.Elmore,,Oh,io and'luckey, Ohio plants. Very truly yours, bc: ,G. S. Blome M. 8. Powers - I .-..I .v......, - ' ..' ...

  20. Microsoft Word - Map and Directions to FrCt.doc

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Frederiksen Court Housing Iowa State University Ames, IA 50011 Ames Laboratory - Public Affairs 111 TASF Iowa State University Ames, IA 50011-3020 Page 1 515.294.9557 1 Enter Ames...

  1. EMRTC Oxidizing Solids Testing FR-10-13.pdf

    Office of Environmental Management (EM)

  2. Notice of Proposed Rulemaking, Federal Register, 75 FR 29933...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    More Documents & Publications EA-1991: Notice of Proposed Rulemaking Green Building Certification Systems Requirement for New Federal Buildings and Major Renovations of Federal ...

  3. Facility Representative Program ID Selects FR of the Year

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... Having basic knowledge and meeting technical competencies related to Nuclear Fundamentals, ... competencies related to specific engineering principles, such as: steam system ...

  4. Notice of Proposed Rulemaking, Federal Register, 75 FR 63404...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    for Fossil Fuel-Generated Energy Consumption Reduction for New Federal Buildings and ... More Documents & Publications Fossil Fuel-Generated Energy Consumption Reduction for New ...

  5. CHPE_ROD_FR_10-01-2014.pdf

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    258 Federal Register / Vol. 79, No. 190 / Wednesday, October 1, 2014 / Notices DEPARTMENT OF ENERGY [OE Docket No. PP-362] Record of Decision for Issuing a Presidential Permit to Champlain Hudson Power Express, Inc., for the Champlain Hudson Power Express Transmission Line Project AGENCY: Office of Electricity Delivery and Energy Reliability, U.S. Department of Energy. ACTION: Record of decision. SUMMARY: The Department of Energy (DOE) announces its decision to issue a Presidential permit to

  6. Zero Liquid Discharge Technology | GE Global Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Reverse Osmosis (RO) Membrane Technology Purifies Water Click to email this to a friend (Opens in new window) Share on Facebook (Opens in new window) Click to share (Opens in new window) Click to share on LinkedIn (Opens in new window) Click to share on Tumblr (Opens in new window) Reverse Osmosis (RO) Membrane Technology Purifies Water GE's Reverse Osmosis (RO) Membrane technology addresses industrial waste water treatment and recycling needs, purifying water for cooling, boilers, and general

  7. An Isotopic Study of the Coso California Geothermal Area | Open...

    Open Energy Info (EERE)

    model previously proposed by Fournier, et e. (1980). Authors R.O. Fournier and J.M. Thompson Conference GRC Annual Meeting; San Diego, California; 19821011 Published Geothermal...

  8. An Evaluation of the Nonlinearity Correction Applied to Atmospheric...

    Office of Scientific and Technical Information (OSTI)

    used in the Atmospheric Radiation Measurement (ARM) Program's AERIs. Authors: Turner, DD ; Revercomb, HE ; Knuteson, RO ; Dedecker, RG ; Feltz, WF Publication Date: ...

  9. Comment permalink | OSTI, US Dept of Energy Office of Scientific...

    Office of Scientific and Technical Information (OSTI)

    Statistical methods for environmental pollution monitoring Gilbert, R.O. (1987) 170 ... Study of using oxygen-enriched combustion air for locomotive diesel engines Poola, R.B.; ...

  10. June 2015 Most Viewed Documents for Environmental Sciences |...

    Office of Scientific and Technical Information (OSTI)

    Statistical methods for environmental pollution monitoring Gilbert, R.O. (1987) 102 ... in vapor compression for refrigeration and air-conditioning in the United States ...

  11. December 2015 Most Viewed Documents for Environmental Sciences...

    Office of Scientific and Technical Information (OSTI)

    methods for environmental pollution monitoring Gilbert, R.O. (1987) 116 Ammonia usage in vapor compression for refrigeration and air-conditioning in the United States ...

  12. September 2015 Most Viewed Documents for Environmental Sciences...

    Office of Scientific and Technical Information (OSTI)

    pollution monitoring Gilbert, R.O. (1987) 126 Building a secondary containment system Broder, M.F. (1994) 121 Study of using oxygen-enriched combustion air for ...

  13. March 2016 Most Viewed Documents for Environmental Sciences ...

    Office of Scientific and Technical Information (OSTI)

    Statistical methods for environmental pollution monitoring Gilbert, R.O. (1987) 170 ... Study of using oxygen-enriched combustion air for locomotive diesel engines Poola, R.B.; ...

  14. MHK Projects/Hope Field Point Project | Open Energy Information

    Open Energy Info (EERE)

    Hope Field Point Project < MHK Projects Jump to: navigation, search << Return to the MHK database homepage Loading map... "minzoom":false,"mappingservice":"googlemaps3","type":"RO...

  15. Geothermometry At Long Valley Caldera Geothermal Area (Mariner...

    Open Energy Info (EERE)

    California R.O. Fournier, Michael L. Sorey, Robert H. Mariner, Alfred H. Truesdell (1979) Chemical and Isotopic Prediction of Aquifer Temperatures in the Geothermal System at Long...

  16. MHK Projects/Santona Wave Energy Park | Open Energy Information

    Open Energy Info (EERE)

    Santona Wave Energy Park < MHK Projects Jump to: navigation, search << Return to the MHK database homepage Loading map... "minzoom":false,"mappingservice":"googlemaps3","type":"RO...

  17. ECIS-UNM: Biomimetic Membranes for Water Purification

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... Reverse osmosis (RO) is currently the best method of desalination (making fresh water from ... A nanoporous biomimetic membrane on a nanostructured support used for water desalination ...

  18. Modeling

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... Limited clean water supplies face further stress due to its required use in a number of industrial processes. Reverse osmosis (RO) is currently the best method of desalination ...

  19. Santa Rosa County, Florida: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    Places in Santa Rosa County, Florida Bagdad, Florida Gulf Breeze, Florida Jay, Florida Milton, Florida Pace, Florida Retrieved from "http:en.openei.orgwindex.php?titleSantaRo...

  20. Cost and Performance Comparison Baseline for Fossil Energy Power...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    steel, single suction 2 1 22 Filtered Water Tank Vertical, cylindrical 1 0 23 Makeup Water Demineralizer Multi-media filter, cartridge filter, RO membrane assembly,...

  1. DISCLAIMER : UNCONTROLLED WHEN PRINTED - PLEASE CHECK THE STATUS...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    IODGCOOTEDHCD Document Security: Internal Use RO: Henderson Mark Read Access LG: EC, GG: IO DDGs (and Senior Advisors), AD: ITER, AD: External Collaborators, AD: IODirector- ...

  2. Outfalls

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    electricity in one 10-megawatt and two 5-megawatt steam turbinesgenerators. Permitted Discharge Cooling towers, boiler blow-down drains, demineralizer backwash, RO reject, ...

  3. Photo of the Week: 2013 | Department of Energy

    Energy Savers [EERE]

    ... The RoHAWKtics team (named after their school mascot) spent ... solar power dish, power plants can burn less fuel. ... of controlling nuclear energy to create useful power. ...

  4. Nanoscale Material Properties | GE Global Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Symposium and Exhibition Focuses on Materials, Surfaces and Interfaces IMG0475 Innovation 247: We're Always Open a57-v-zero-liquid-discharge Reverse Osmosis (RO)...

  5. United States

    Office of Legacy Management (LM)

    ... k?-b-109 155m artillery fired atouic &;ro.jectile (AF(F) ... In the Northern Alabama Coal Gasification Project and ... ,..--. -. ctlomue alnmmia plant . ..-.----...-.-..-.-... ...

  6. June 2016 Most Viewed Documents for Environmental Sciences |...

    Office of Scientific and Technical Information (OSTI)

    Statistical methods for environmental pollution monitoring Gilbert, R.O. (1987) 138 ... in vapor compression for refrigeration and air-conditioning in the United States ...

  7. Chemical and Isotopic Prediction of Aquifer Temperatures in the...

    Open Energy Info (EERE)

    of Aquifer Temperatures in the Geothermal System at Long Valley, California Authors R.O. Fournier, Michael L. Sorey, Robert H. Mariner and Alfred H. Truesdell Published Journal...

  8. No maintenance -- no energy efficiency

    SciTech Connect (OSTI)

    Szydlowski, R.F.; Schliesing, J.S.; Winiarski, D.W.

    1994-12-01

    Field investigations illustrate that it is not realistic to expect new high-tech equipment to function for a full life expectancy at high efficiency without significant operations and maintenance (O&M). A simple walk through inspection of most buildings reveals extensive equipment that is being operated on manual override, is incorrectly adjusted and operating inefficiently, or is simply inoperative. This point is illustrated with two examples at Robins Air Force Base, Georgia. The first describes development of a comprehensive, base-wide, steam trap maintenance program. The second describes a measured evaluation from a typical office building. The objective of both examples was to assess the importance of proper O&M. The proposed ``O&M First`` philosophy will result in more efficient building HVAC operation, provide improved services to the building occupants, and reduce energy consumption and unscheduled equipment repair/replacement. Implementation of a comprehensive O&M program will result in a 15--25% energy savings. The O&M foundation that is established will allow other energy conservation activities such is demand side management or energy management and control systems, to achieve and maintain their expected energy savings.

  9. Machine learning of parameters for accurate semiempirical quantum chemical calculations

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Dral, Pavlo O.; von Lilienfeld, O. Anatole; Thiel, Walter

    2015-04-14

    We investigate possible improvements in the accuracy of semiempirical quantum chemistry (SQC) methods through the use of machine learning (ML) models for the parameters. For a given class of compounds, ML techniques require sufficiently large training sets to develop ML models that can be used for adapting SQC parameters to reflect changes in molecular composition and geometry. The ML-SQC approach allows the automatic tuning of SQC parameters for individual molecules, thereby improving the accuracy without deteriorating transferability to molecules with molecular descriptors very different from those in the training set. The performance of this approach is demonstrated for the semiempiricalmore » OM2 method using a set of 6095 constitutional isomers C7H10O2, for which accurate ab initio atomization enthalpies are available. The ML-OM2 results show improved average accuracy and a much reduced error range compared with those of standard OM2 results, with mean absolute errors in atomization enthalpies dropping from 6.3 to 1.7 kcal/mol. They are also found to be superior to the results from specific OM2 reparameterizations (rOM2) for the same set of isomers. The ML-SQC approach thus holds promise for fast and reasonably accurate high-throughput screening of materials and molecules.« less

  10. Properties measurements of (U{sub 0.7}Pu{sub 0.3})O{sub 2-x} in PO{sub 2}-controlled atmosphere

    SciTech Connect (OSTI)

    Kato, M.; Murakami, T.; Sunaoshi, T.; Nelson, A.T.; McClellan, K.J.

    2013-07-01

    The investigation of physical properties of uranium and plutonium mixed oxide (MOX) fuels is important for the development of fast reactor fuels. It is well known that MOX is a nonstoichiometric oxide, and the physical properties change drastically with the Oxygen-to-Metal (O/M) ratio. A control technique for O/M ratio was established for measurements of high temperature properties of uranium and plutonium mixed oxide fuels. Sintering behavior, thermal expansion and O/M change of (U{sub 0.7}Pu{sub 0.3})O{sub 2.00} and (U{sub 0.7}Pu{sub 0.3})O{sub 1.99} were investigated in PO{sub 2}-controlled atmosphere which was controlled by H{sub 2}/H{sub 2}O gas system. Sintering behavior changed drastically with O/M ratio, and shrinkage of (U{sub 0.7}Pu{sub 0.3})O{sub 2.00} was faster and more advanced at lower temperatures as compared with (U{sub 0.7}Pu{sub 0.3})O{sub 1.99}. Thermal expansion was observed to be slightly increased with decreasing O/M ratio. (authors)

  11. DOE - Fossil Energy:

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    as all procedural orders; i.e., vacations, name changes. Blanket Authorizations with no activity for more than five years vacated by F.R. Notice (70 F.R. 38943), August 22, 2005....

  12. Recent Federal Register Notices | Department of Energy

    Office of Environmental Management (EM)

    ... 80FR52210 08272015 Average Unit Cost of Energy N Notice of forecasting the representative average unit costs of energy 80FR52039 08262015 Commercial Fans and Blowers N Notice ...

  13. http://ecfr.gpoaccess.gov/cgi/t/text/text-idx?c=ecfr&sid=49039f

    National Nuclear Security Administration (NNSA)

    ... Inventory start date means the first day of the inventory ... as amended at 65 FR 8657, Feb. 22, 2000; 72 FR 38792, July 16, ... listed pollutant in 2008, 2013, and 2018, are less than ...

  14. http://ecfr.gpoaccess.gov/cgi/t/text/text-idx?c=ecfr&sid=5b4288

    National Nuclear Security Administration (NNSA)

    ... whichever date occurs first. b Page 10 of 180 ... 19, 2009; 75 FR 6531, Feb. 9, 2010; 75 FR 35592, June 22, 2010 50.15 ... a 2010-2012 (or 2011- 2013) Pb design value that ...

  15. Automation of oil movement systems prevents mistakes, saves money

    SciTech Connect (OSTI)

    King, M. )

    1993-03-22

    Experiences illustrate how oil movement and storage (OM and S) system automation can be justified and its benefits proven. From such examples, refiners can determine sources of project benefits and how project costs can be reduced without causing equivalent reductions in benefits. A number of examples also demonstrate the importance of designing an integrated information system, as opposed to a stand-alone OM and S system. This first of two articles covers project justification opportunities. Part two will discuss automatic data reconciliation, refinery information systems, yield reconciliation, and the decision to design or purchase an automated OM and S system. The paper describes the project benefits and gives examples: blending, planning spot cargos, inventory reduction, demurrage, recycling slop materials, routing errors, premature action, safety, unusual routings, incident analysis, and man-hour scheduling.

  16. Browse by Discipline -- E-print Network Subject Pathways: Biotechnolog...

    Office of Scientific and Technical Information (OSTI)

    ... Ben (Ben Marzeion) - Institut fr Geographie, Universitt Innsbruck Masiello, Carrie (Carrie Masiello) - Department of Earth Science, Rice University Maslowski, Wieslaw ...

  17. Browse by Discipline -- E-print Network Subject Pathways: Computer...

    Office of Scientific and Technical Information (OSTI)

    ... Ulm, Universitt - Fakultt fr Mathematik und Wirtschaftswissenschaften Universidad de la Repblica, Instituto de Matemtica y Estadstica "Prof. Ing. Rafael Laguardia" ...

  18. POLICY FLASH 2015-37- FAC 2005-84

    Broader source: Energy.gov [DOE]

    FAR amendments, Federal Register at 80 FR 53436. FAC 2005-84 issued 1 final rule and technical amendments

  19. Delegation Order No. 0204-59 to the Governor of the State of Wisconsin

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1992-06-03

    Rescinded by: 57 FR 23932, effective June 3, 1992 The statutory bases for this regulation no longer exist.

  20. Delegation Order No. 0204-58 to the Governor of the State of South Carolina

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1992-06-03

    Rescinded by: 57 FR 23932, effective June 3, 1992 The statutory bases for this regulation no longer exist.

  1. Delegation Order No. 0204-56 to the Governor of the State of Maine

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1992-06-03

    Rescinded by: 57 FR 23932, effective June 3, 1992 The statutory bases for this regulation no longer exist.

  2. Delegation Order No. 0204-40 to the Government of the State of Arizona

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1992-06-03

    Rescinded by: 57 FR 23932, effective June 3, 1992 The statutory bases for this regulation no longer exist.

  3. Delegation Order No. 0204-60 to the Governor of the State of Kentucky

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1992-06-03

    Rescinded by: 57 FR 23932, effective June 3, 1992 The statutory bases for this regulation no longer exist.

  4. ENVIROISSUES PAGE

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Local Government Meynard ?1hU1a Pam Laen RoDer Larson Jerry Peltier Jim Curdy Bob Parks ... HBl1ford Pr.j.t Office " .713 Jidwin. uile4 Ff COrulcTtsUS ArlVloo 168 Ro:hland, W ...

  5. FIA-12-0001- In the Matter of Kevin Leary

    Broader source: Energy.gov [DOE]

    OHA issued a decision denying a FOIA appeal filed by Kevin Leary of a final determination issued by the DOE Richland Operations Office (RO). Mr. Leary requested copies of e-mails, the associated metadata, and instant messages for Margot Voogd, Larry Romine and Bryan Foley, from August 1, 2005, through January 31, 2009. RO informed Mr. Leary that no documents existed.

  6. A=20Ne (1987AJ02)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    1986VA18, 1986VA23, 1986WE1C, 1987FA09, 1987KO15, 1987NI04, 1987RI03, 1987RO10). Muon and neutrino capture and reactions: (1983RO1E, 1984EL1D, 1984GR03, 1985MI1D,...

  7. Model Calibration and Forward Uncertainty Quantification for...

    Office of Scientific and Technical Information (OSTI)

    ... ludRoChain Monte Carlo algorithm -H-y-rr,-, I-tff ;n- t-.v-.i. ?v.:; Sandia ... ludRoChain Monte Carlo algorithm -H-y-rr,-, I-tff ;n- t-.v-.i. ?v.:; Sandia ...

  8. Noise Exposure Summary And Comparitive Analyses

    SciTech Connect (OSTI)

    Bumala, Philip A.

    2013-11-18

    This paper summarizes and compares facility Operations and Maintenance (O&M) noise Dosimetry data to industry wide construction data. Dosimetry data has been compiled from a noise exposure assessment at a DOE national research facility Maintenance, Utilities, and Service Department (MUSD). This facility is the Lawrence Livermore National Laboratory (LLNL). The laboratory consists of ten O&M craft and trade shops responsible for a fifty year old infrastructure including over 300 buildings, and a worker population of approximately 7,000. The facility includes an extensive variety of noise generating activities throughout a one square mile site.

  9. On Enhancing Risk Monitors for Advanced Small Modular Reactors

    SciTech Connect (OSTI)

    Coble, Jamie B.; Coles, Garill A.; Meyer, Ryan M.; Ramuhalli, Pradeep

    2013-08-01

    Advanced small modular reactors (AdvSMRs) can contribute to safe, sustainable, and carbon-neutral energy production. However, the economics of AdvSMRs suffer from the loss of economy-of-scale for both construction and operation. The controllable day-to-day costs of AdvSMRs are expected to be dominated by operations and maintenance (O&M) costs. These expenses could potentially be managed through optimized scheduling of O&M activities for components, reactor modules, power blocks, and the full plant. Accurate, real-time risk assessment with integrated health monitoring of key active components can support scheduling of both online and offline inspection and maintenance activities.

  10. Emissions comparison of alternative fuels in an advanced automotive diesel engine. Interim report, October 1997--April 1998

    SciTech Connect (OSTI)

    Sirman, M.B.; Owens, E.C.; Whitney, K.A.

    1998-09-01

    Exhaust emissions mappings were conducted for six alternative diesel fuels in a Daimler-Benz (DB) OM6l1 diesel engine. The OM6l 1 engine is a 2.2L, direct-injection diesel with a Bosch, high-pressure, common-rail, fuel-injection system. The engine design closely matches the specifications of the Partnership for a New Generation Vehicle (PNGV) target compression-ignition engine. Triplicate 13-mode, steady-state test sequences were performed for each fuel, with a 2-D control fuel serving as the baseline. No adjustments were made to the engine to compensate for any performance differences resulting from fuel property variations.

  11. DOE/EA-2008: Colorado River Storage Project Programmatic Operations and Maintenance Project; Coconino, Maricopa, Navajo, and Yavapai Counties (Arizona) and San Juan County (Utah)

    Broader source: Energy.gov [DOE]

    Western Area Power Administration is preparing an EA that assesses the potential environmental impacts of Westerns programmatic operations and management (O&M) process and an integrated vegetation management (IVM) program on the Colorado River Storage Project System. O&M activities would consist of aerial and ground patrols, regular and preventive maintenance, inspections and repairs, and road repair. The IVM program would remove vegetation to protect facilities from fire, control the spread of noxious weeds to protect environmental quality, establish and maintain stable, low-growing plant communities in the ROW, and activities for public and worker safety around transmission lines and other facilities.

  12. Highly Selective Adsorption of Ethylene over Ethane in a MOF Featuring the Combination of Open Metal Site and -Complexation

    SciTech Connect (OSTI)

    Zhang, Yiming; Li, Baiyan; Wu, Zili; Ma, Shengqian

    2015-01-09

    The introduction of the combination of open metal site (OMS) and -complexation into MOF has led to very high ethylene/ethane adsorption selectivity at 318K, as illustrated in the context of MIL-101-Cr-SO3Ag. The interactions with ethylene from both OMS and -complexation in MIL-101-Cr-SO3Ag have been investigated by in situ IR spectroscopic studies and computational calculations, which suggest -complexation contributes dominantly to the high ethylene/ethane adsorption selectivity.

  13. Approaches used for Clearance of Lands from Nuclear Facilities among Several Countries: Evaluation for Regulatory Input

    Office of Environmental Management (EM)

    :14 Report number: 2013:14 ISSN: 2000-0456 Available at www.stralsakerhetsmyndigheten.se Approaches used for Clearance of Lands from Nuclear Facilities among Several Countries Evaluation for Regulatory Input Robert A. Meck Author: SSM perspektiv SSM har nyligen beslutat om föreskrifter om friklassning av material, loka- ler, byggnader och mark vid verksamhet med joniserande strålning (SSMFS 201 1:2). Föreskrifterna innehåller bland annat krav på att tillståndshavare, vid avveckling av

  14. Fossil plant cycling impacts on feedwater heaters

    SciTech Connect (OSTI)

    O`Connor, D.

    1995-12-01

    As the U.S. electric utility industry faces the most challenging period in its history, EPRI research is focused on providing products and services that help utilities meet these challenges. Currently, a dominant issue for fossil plants is the need to reduce operation and maintenance costs in order to maintain their profitability in an increasingly competitive business environment. Cycling operation can significantly effect plant O&M costs and must, therefore be done in the most effective and efficient manner. Ongoing R&D is providing new products and strategies addressing cycling operation that utilities can implement to optimize O&M costs for least-cost power production.

  15. Solar Access Public Capital (SAPC) Working Group: Best Practices in PV Operations and Maintenance; Version 1.0, March 2015; Period of Performance, January 1, 2014 - December 31, 2015

    SciTech Connect (OSTI)

    Keating, T. J.; Walker, A.; Ardani, K.

    2015-03-01

    This PV O&M Best Practices Guide is designed to improve solar asset transparency for investors and rating agencies, provide an industry framework for quality management, and reduce transaction costs in the solar asset securitization process. The PV O&M Best Practices Guide is intended to outline the minimum requirements for third-party ownership providers (“Providers”). Adherence to the guide is voluntary. Providers that adhere to the guide are responsible for selfcertifying that they have fulfilled the guide requirements.

  16. EA-2008: Colorado River Storage Project Programmatic Operations and Maintenance Project; Coconino, Maricopa, Navajo, and Yavapai Counties (Arizona) and San Juan County (Utah)

    Broader source: Energy.gov [DOE]

    Western Area Power Administration is preparing an EA that assesses the potential environmental impacts of Western’s programmatic operations and management (O&M) process and an integrated vegetation management (IVM) program on the Colorado River Storage Project System. O&M activities would consist of aerial and ground patrols, regular and preventive maintenance, inspections and repairs, and road repair. The IVM program would remove vegetation to protect facilities from fire, control the spread of noxious weeds to protect environmental quality, establish and maintain stable, low-growing plant communities in the ROW, and activities for public and worker safety around transmission lines and other facilities.

  17. Precursor Report of Data Needs and Recommended Practices for PV Plant Availability Operations and Maintenance Reporting.

    SciTech Connect (OSTI)

    Hill, Roger R.; Klise, Geoffrey Taylor; Balfour, John R.

    2015-01-01

    Characterizing the factors that affect reliability of a photovoltaic (PV) power plant is an important aspect of optimal asset management. This document describes the many factors that affect operation and maintenance (O&M) of a PV plant, identifies the data necessary to quantify those factors, and describes how data might be used by O&M service providers and others in the PV industry. This document lays out data needs from perspectives of reliability, availability, and key performance indicators and is intended to be a precursor for standardizing terminology and data reporting, which will improve data sharing, analysis, and ultimately PV plant performance.

  18. Establishing an In-House Wind Maintenance Program

    SciTech Connect (OSTI)

    2011-12-01

    Update to the 2008 guidebook titled “Establishing an In-house Wind Maintenance Program”, which was developed to support utilities in developing O&M strategies. This update includes significant contributions from utilities and other stakeholders around the country, representing all perspectives and regardless of whether or not they own wind turbines or projects.

  19. Wind turbine reliability :understanding and minimizing wind turbine operation and maintenance costs.

    SciTech Connect (OSTI)

    Walford, Christopher A. (Global Energy Concepts. Kirkland, WA)

    2006-03-01

    Wind turbine system reliability is a critical factor in the success of a wind energy project. Poor reliability directly affects both the project's revenue stream through increased operation and maintenance (O&M) costs and reduced availability to generate power due to turbine downtime. Indirectly, the acceptance of wind-generated power by the financial and developer communities as a viable enterprise is influenced by the risk associated with the capital equipment reliability; increased risk, or at least the perception of increased risk, is generally accompanied by increased financing fees or interest rates. This paper outlines the issues relevant to wind turbine reliability for wind turbine power generation projects. The first sections describe the current state of the industry, identify the cost elements associated with wind farm O&M and availability and discuss the causes of uncertainty in estimating wind turbine component reliability. The latter sections discuss the means for reducing O&M costs and propose O&M related research and development efforts that could be pursued by the wind energy research community to reduce cost of energy.

  20. Certification for DOE O 542.2A, Unsolicited Proposals

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2006-12-28

    DOE Order 542.2A has been reviewed by my organization and is deemed to be in compliance with related Departmental Directives, Secretarial Delegation, organizational structure, budget guidelines, rules, regulations, standards, OMS guidance, relevant memorandums of understanding and public laws.

  1. Establishing an In-House Wind Maintenance Program

    SciTech Connect (OSTI)

    2011-12-01

    Update to the 2008 guidebook titled Establishing an In-house Wind Maintenance Program, which was developed to support utilities in developing O&M strategies. This update includes significant contributions from utilities and other stakeholders around the country, representing all perspectives and regardless of whether or not they own wind turbines or projects.

  2. New mammography screen/film combinations: Imaging characteristics and radiation dose

    SciTech Connect (OSTI)

    Kimme-Smith, C.; Bassett, L.W.; Gold, R.H.; Zheutlin, J.; Gornbein, J.A. )

    1990-04-01

    Five types of film (Kodak OM, Kodak OM-SO177, Konica CM, Dupont Microvision, and Fuji MiMa) exposed in combination with seven different intensifying screens (Min R, Min R Medium, Siemens Orthox MA, Kyokka HR Mammo Fine, Agfa Gevaert Detail S (old and new), and Konica Monarch) were processed for either 90 sec (at 33.3{degrees}C) or 3 min (at 35.0 degrees C). The films imaged a Computerized Imaging Reference System phantom with additional detail test objects placed on its surface to produce four groups of objects with which to evaluate resolution and contrast. For objects that tested resolution, the Kyokka HR Mammo Fine (Fuji) screen was statistically significantly superior; for objects that tested contrast, the Konica Monarch screen was statistically significantly superior. Extended processing did not affect Dupont and Kodak OM film as much as it affected the other films. It did affect contrast for the other films tested. The mean glandular doses from gridless exposures ranged from 32 to 80 mrad (0.32-0.80 mGy) over all film/screen/processing combinations for a 4.5-cm-thick test object. Several new film/screen combinations can provide images superior to the Kodak Min R/OM combination at a reduced radiation dose. The Kyokka HR Mammo Fine (Fuji) screen was found statistically superior in radiographic resolution of mammographic test objects and the Konica Monarch screen was found to be superior in defining contrast.

  3. NERSC-ScienceHighlightsJune2014.pptx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    a gyrokine0c p lasma s imula0on d one at N ERSC w ith f ast i ons ( top) a nd without ( bo;om), s howing h ow microinstabili0es d riven by large gradients i n t emperature a nd...

  4. ICD Complex Operations and Maintenance Plan

    SciTech Connect (OSTI)

    Gibson, P. L.

    2007-06-25

    This Operations and Maintenance (O&M) Plan describes how the Idaho National Laboratory (INL) conducts operations, winterization, and startup of the Idaho CERCLA Disposal Facility (ICDF) Complex. The ICDF Complex is the centralized INL facility responsible for the receipt, storage, treatment (as necessary), and disposal of INL Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) remediation waste.

  5. OpenEI Community

    Open Energy Info (EERE)

    1 Oct 2015 - 11:17 0 Where might I find simplified Data on Capital, O&M, and fuel costs? 25 Sep 2015 - 14:15 1 How to access older versions of rates? 7 Sep 2015 - 17:22 1 Do...

  6. M S

    Office of Legacy Management (LM)

    at Rew3x3 Brass and Copper co. 0.. i7-Lm .3 6, 194.6. One pure bwylUm L&" billet m m &r&d into a 1 l8' * rod and one pure beryllium ' billet n-as extrLlc-c?c into 1,53om disn. ...

  7. Oak Ridge Site Specific Advisory ...

    Office of Environmental Management (EM)

    * Fax: 865-241-6932 * Internet: www.oakridge.doe.govemssab M Ma an ny y V Vo oi ic ce es s W Wo or rk ki in ng g f fo or r t th he e C Co om mm mu un ni it ty y O O a a ...

  8. Oak Ridge Site Specific Advisory Board Monthly Meeting W W W

    Office of Environmental Management (EM)

    ... * Fax: 865-241-6932 * Internet: www.oakridge.doe.govemssab M Ma an ny y V Vo oi ic ce es s W Wo or rk ki in ng g f fo or r t th he e C Co om mm mu un ni it ty y O O a a ...

  9. CX-100379 Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Automating Solar Power Plants: Creating automated software and hardware tools to lower development, construction and O&M costs at utility-scale projects Award Number: DE-EE0007179 CX(s) Applied: A9, A11, B3.2 Solar Energy Technologies Office Date: 09/16/2015 Location: California Office(s): Golden Field Office

  10. Summation over histories for a particle in spherical orbit around a black hole

    SciTech Connect (OSTI)

    Bernido, C.C.; Aguarte, G.

    1997-08-01

    An exact path integral treatment of a relativistic scalar particle in a spherical orbit around a Reissner-Nordstr{umlt o}m and Schwarzschild black hole is presented. A closed form for the Green function and the energy spectrum are obtained. {copyright} {ital 1997} {ital The American Physical Society}

  11. Effects of Levels of Automation for Advanced Small Modular Reactors: Impacts on Performance, Workload, and Situation Awareness

    SciTech Connect (OSTI)

    Johanna Oxstrand; Katya Le Blanc

    2014-07-01

    The Human-Automation Collaboration (HAC) research effort is a part of the Department of Energy (DOE) sponsored Advanced Small Modular Reactor (AdvSMR) program conducted at Idaho National Laboratory (INL). The DOE AdvSMR program focuses on plant design and management, reduction of capital costs as well as plant operations and maintenance costs (O&M), and factory production costs benefits.

  12. CX-012334: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Install Single Split System Air Conditioning Unit in Bryan Mound Building No. 281 (BM-OM-1229) CX(s) Applied: B1.4 Date: 06/30/2014 Location(s): Texas Offices(s): Strategic Petroleum Reserve Field Office

  13. Operations & Maintenance Best Practices - A Guide to Achieving Operational Efficiency Release 3.0

    SciTech Connect (OSTI)

    2010-08-01

    This Operations and Maintenance (O&M) Best Practices Guide was developed under the direction of the U.S. Department of Energy’s Federal Energy Management Program (FEMP). The mission of FEMP is to facilitate the Federal Government’s implementation of sound, cost effective energy management and investment practices to enhance the nation’s energy security and environmental stewardship.

  14. Colville Resident Trout Hatchery Project Supplement Analysis (DOE/EA-0307-SA-01)

    SciTech Connect (OSTI)

    N /A

    2003-10-02

    The Bonneville Power Administration prepared an Environmental Assessment (DOE/EA-0307) for the Colville Resident Hatchery Project (Project) and published a Finding of No Significant Impact (FONSI) in the Federal Register on September 8, 1986 (Vol. 51, No.173). The Project involved the design, site selection, construction, operation and maintenance of a resident trout hatchery on the Colville Indian Reservation to partially mitigate for anadromours and other fish losses resulting from the construction and operation of the Chief Joseph Dam and Grand Coulee Dam hydroelectric projects. Since the hatchery was constructed, ongoing Operation and Maintenance (O&M) and Monitoring and Evaluation (M&E) activities have been funded by BPA. The O&M and M&E activities examined in the EA were very general in nature due to the fact the project was in the conceptual stage. Since that time the hatchery has refined the need for specific O&M and M&E activities, proposed for fiscal year 2004, (funding for projects runs from October 2003 to September 2004). The purpose of this Supplement Analysis (SA) is to determine if a supplemental EA is needed to analyze the environmental impacts that would result from the specific O&M and M&E activities proposed for fiscal year 2004.

  15. OpenEI Community

    Open Energy Info (EERE)

    1 Oct 2015 - 10:17 1 Where might I find simplified Data on Capital, O&M, and fuel costs? 25 Sep 2015 - 13:15 1 How to access older versions of rates? 7 Sep 2015 - 16:22 1...

  16. Sulfur oxide adsorbents and emissions control

    DOE Patents [OSTI]

    Li, Liyu; King, David L.

    2006-12-26

    High capacity sulfur oxide absorbents utilizing manganese-based octahedral molecular sieve (Mn--OMS) materials are disclosed. An emissions reduction system for a combustion exhaust includes a scrubber 24 containing these high capacity sulfur oxide absorbents located upstream from a NOX filter 26 or particulate trap.

  17. Physician Beliefs and Practices for Adjuvant and Salvage Radiation Therapy After Prostatectomy

    SciTech Connect (OSTI)

    Showalter, Timothy N.; Ohri, Nitin; Teti, Kristopher G.; Foley, Kathleen A.; Keith, Scott W.; Trabulsi, Edouard J.; Lallas, Costas D.; Dicker, Adam P.; Hoffman-Censits, Jean; Pizzi, Laura T.; Gomella, Leonard G.

    2012-02-01

    Purpose: Despite results of randomized trials that support adjuvant radiation therapy (RT) after radical prostatectomy (RP) for prostate cancer with adverse pathologic features (APF), many clinicians favor selective use of salvage RT. This survey was conducted to evaluate the beliefs and practices of radiation oncologists (RO) and urologists (U) regarding RT after RP. Methods and Materials: We designed a Web-based survey of post-RP RT beliefs and policies. Survey invitations were e-mailed to a list of 926 RO and 591 U. APF were defined as extracapsular extension, seminal vesicle invasion, or positive surgical margin. Differences between U and RO in adjuvant RT recommendations were evaluated by comparative statistics. Multivariate analyses were performed to evaluate factors predictive of adjuvant RT recommendation. Results: Analyzable surveys were completed by 218 RO and 92 U (overallresponse rate, 20%). Adjuvant RT was recommended based on APF by 68% of respondents (78% RO, 44% U, p <0.001). U were less likely than RO to agree that adjuvant RT improves survival and/or biochemical control (p < 0.0001). PSA thresholds for salvage RT were higher among U than RO (p < 0.001). Predicted rates of erectile dysfunction due to RT were higher among U than RO (p <0.001). On multivariate analysis, respondent specialty was the only predictor of adjuvant RT recommendations. Conclusions: U are less likely than RO to recommend adjuvant RT. Future research efforts should focus on defining the toxicities of post-RP RT and on identifying the subgroups of patients who will benefit from adjuvant vs. selective salvage RT.

  18. Diversity Based on Race, Ethnicity, and Sex, of the US Radiation Oncology Physician Workforce

    SciTech Connect (OSTI)

    Chapman, Christina H.; Hwang, Wei-Ting; Deville, Curtiland

    2013-03-15

    Purpose: To assess the current diversity of the US radiation oncology (RO) physician workforce by race, ethnicity, and sex. Methods and Materials: Publicly available American Medical Association, American Association of Medical Colleges, and US census registries were used to assess differences by race, ethnicity, and sex for 2010 among RO practicing physicians, academic faculty, residents, and residency applicants. RO resident diversity was compared to medical school graduates and medical oncology (MO) fellows. Significant differences in diversity of RO residents by race, ethnicity, and sex were evaluated between 2003 and 2010 academic years. Results: Females and traditionally underrepresented minorities in medicine (URM), blacks, Hispanics, American Indians, Alaska Natives, Native Hawaiian, and Pacific Islanders are underrepresented as RO residents (33.3% and 6.9%, respectively), faculty (23.8%, 8.1%), and practicing physicians (25.5%, 7.2%) levels compared with the US population (50.8%, 30.0%; P<.01). Although females and URMs remain underrepresented at the resident trainee level compared with their proportions as medical school graduates (48.3%, 15.6%) and MO fellows (45.0%, 10.8%; P<.01), females are significantly increased in proportion as RO residents compared with RO practicing physicians (P<.01), whereas representation of individual URM groups as RO residents is no different than current practicing physicians. There is no trend toward increased diversification for female or URM trainees over 8 years, suggesting underrepresentation is not diminishing. Conclusions: Females and URM are underrepresented in the RO physician workforce. Given existing cancer disparities, further research and efforts are needed to ensure that the field is equipped to meet the needs of an increasingly diverse society.

  19. Mechanisms of olfactory toxicity of the herbicide 2,6-dichlorobenzonitrile: Essential roles of CYP2A5 and target-tissue metabolic activation

    SciTech Connect (OSTI)

    Xie Fang; Zhou Xin; Behr, Melissa; Fang Cheng; Horii, Yuichi; Gu Jun; Kannan, Kurunthachalam; Ding Xinxin

    2010-11-15

    The herbicide 2,6-dichlorobenzonitril (DCBN) is a potent and tissue-specific toxicant to the olfactory mucosa (OM). The toxicity of DCBN is mediated by cytochrome P450 (P450)-catalyzed bioactivation; however, it is not known whether target-tissue metabolic activation is essential for toxicity. CYP2A5, expressed abundantly in both liver and OM, was previously found to be one of the P450 enzymes active in DCBN bioactivation in vitro. The aims of this study were to determine the role of CYP2A5 in DCBN toxicity in vivo, by comparing the extents of DCBN toxicity between Cyp2a5-null and wild-type (WT) mice, and to determine whether hepatic microsomal P450 enzymes (including CYP2A5) are essential for the DCBN toxicity, by comparing the extents of DCBN toxicity between liver-Cpr-null (LCN) mice, which have little P450 activity in hepatocytes, and WT mice. We show that the loss of CYP2A5 expression did not alter systemic clearance of DCBN (at 25 mg/kg); but it did inhibit DCBN-induced non-protein thiol depletion and cytotoxicity in the OM. Thus, CYP2A5 plays an essential role in mediating DCBN toxicity in the OM. In contrast to the results seen in the Cyp2a5-null mice, the rates of systemic DCBN clearance were substantially reduced, while the extents of DCBN-induced nasal toxicity were increased, rather than decreased, in the LCN mice, compared to WT mice. Therefore, hepatic P450 enzymes, although essential for DCBN clearance, are not necessary for DCBN-induced OM toxicity. Our findings form the basis for a mechanism-based approach to assessing the potential risks of DCBN nasal toxicity in humans.

  20. Final Rule, Federal Register, 72 FR 72565, 10 CFR Parts 433,...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Document displays the final rulemaking for Energy Conservation Standards for New Federal Commercial and Multi-Family High-Rise Residential Buildings and New Federal Low-Rise ...

  1. EIS-0517: FERC Notice of Intent to Prepare an Environmental Impact Statement (FR)

    Broader source: Energy.gov [DOE]

    Port Arthur Liquefaction Project and Port Arthur Pipeline Project; Jefferson and Orange Counties, Texas, and Cameron Parish, Louisiana

  2. Notice of Proposed Rulemaking, Federal Register, 72 FR 33696, 10 CFR Part 436, June 19, 2007

    Broader source: Energy.gov [DOE]

    Document displays the notice of proposed rulemaking for Federal Procurement of Energy-Efficient Products, which was published in the Federal Register on June 19, 2007.

  3. Notice of Availability, Federal Register, 64 FR 3492, January 22, 1999

    Broader source: Energy.gov [DOE]

    Document displays a notice of availability pertaining to the Availability of Product Energy Efficiency Recommendations, which was published in the Federal Register on January 22, 1999.

  4. Notice and Request for Comments, Federal Register, 71 FR 7749, February 14, 2006

    Broader source: Energy.gov [DOE]

    Document displays the notice and request for comments for Standard for Premium Energy-Efficient Electric Motors for Federal Acquisition, which was published in the Federal Register on February 14, 2006.

  5. Exploratory Technology Research Program for electrochemical energy storage. Annual report fr 1994

    SciTech Connect (OSTI)

    Kinoshita, K.

    1995-09-01

    The US Department of Energy`s Office of Propulsion Systems provides support for an Electrochemical Energy Storage Program, that includes research and development (R&D) on advanced rechargeable batteries and fuel cells. A major goal of this program is to develop electrochemical power sources suitable for application in electric vehicles (EVs). The program centers on advanced systems that offer the potential for high performance and low life-cycle costs, both of which are necessary to permit significant penetration into commercial markets. The DOE Electrochemical Energy Storage Program is divided into two projects: the Electric Vehicle Advanced Battery Systems (EVABS) Development Program and the Exploratory Technology Research (ETR) Program. The general R&D areas addressed by the program include identification of new electrochemical couples for advanced batteries, determination of technical feasibility of the new couples, improvements in battery components and materials, establishment of engineering principles applicable to electrochemical energy storage and conversion, and the development of air-system (fuel cell, metal/air) technology for transportation applications. Major emphasis is given to applied research which will lead to superior performance and lower life-cycle costs. The ETR Program is divided into three major program elements: Exploratory Research, Applied Science Research, and Air Systems Research. Highlights of each program element are summarized according to the appropriate battery system or electrochemical research area.

  6. Final Rule, Federal Register, 74 FR 10830, 10 CFR Part 436, March...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Product Procurement: Executive, Legislative and Regulatory Requirements, Actions and Mandates Sample Contract Language for Construction Using Energy-Efficient Products

  7. PMC*Fr.. U.S. Dl?PARThIENT OFFNFRGY EERE PROJECT MANAGEMENT CE...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    U.S. Dl?PARThIENT OFFNFRGY EERE PROJECT MANAGEMENT CETER NlPA DFllNATION ... publication and distribution, and classroom training and informational programs), ...

  8. Microsoft Word - FR Notice - DOE CMS RFI 02-03-2016 FINAL

    Office of Environmental Management (EM)

    In order to update the 2010 and 2011 analyses, DOE is seeking information from stakeholders on rare earth elements and other materials used in an array of energy technologies, as ...

  9. Finding of No Significant Impact, Federal Register, 73 FR 2017, January 11, 2008

    Broader source: Energy.gov [DOE]

    Document details the finding of no significant impact of the Energy-Efficient Performance Requirements for New Federal Commercial and Residential Buildings, which was published in the Federal Register on January 11, 2008.

  10. Notice of Public Meeting, Federal Register, 66 FR 50177, October 2, 2001

    Broader source: Energy.gov [DOE]

    Document displays a notice of public meeting for Federal Purchasing of Energy-Efficient Standby Power Devices, which was published in the Federal Register on October 2, 2001.

  11. Notice of Final Determination, Federal Register, 71 FR 47791, August 18, 2006

    Broader source: Energy.gov [DOE]

    Document displays the notice of final determination on Standard for Premium Energy-Efficient Electric Motors for Federal Acquisition, which was published in the Federal Register on August 18, 2006.

  12. MHK Projects/SEAREV Pays de la Loire FR | Open Energy Information

    Open Energy Info (EERE)

    1 Project Details The five year goal of the SEAREV project is to launch a 500 kW prototype in the water off of the Pays de la Loire region. Project Installed Capacity (MW) 1...

  13. 2009 Federal Register, 74 FR 50239; Centralized Library: U.S...

    National Nuclear Security Administration (NNSA)

    ... through the NPS Planning, Environment and Public Comment (PEPC) Web site at http:parkplanning.nps.govcuva, the Park's Web site at http:www.nps.gov cuva, and local newspapers. ...

  14. 2009 Federal Register, 74 FR 66147; Centralized Library: U.S...

    National Nuclear Security Administration (NNSA)

    ... Internet web site as follows: http:www.fws.govmerrittisland subrefugesSJ.html. ... Johns NWR. The refuge's Web site, VerDate Nov<24>2008 17:54 Dec 11, 2009 Jkt 220001 PO ...

  15. Microsoft Word - FR Notice - DOE CMS RFI 02-03-2016 FINAL

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    6450-01-P DEPARTMENT OF ENERGY Request for Information (RFI) for Updated Critical Materials Strategy AGENCY: Office of Energy Policy and Systems Analysis, Department of Energy ACTION: Notice of Request for Information (RFI) SUMMARY: In 2010, the U.S. Department of Energy (DOE) developed and issued a Critical Materials Strategy report addressing the role of rare earth and other materials in energy technologies and processes. An update and additional analyses were completed the following year. In

  16. Final Rule, Federal Register, 74 FR 10830, 10 CFR Part 436, March 13, 2009

    Broader source: Energy.gov [DOE]

    Document details the final rulemaking for the Federal Procurement of Energy-Efficient Products, which was published in the Federal Register on March 13, 2009.

  17. 2008 FERC Published ASCM_FRN_74_FR_47052-01_9-30-09_1741

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    with Bonneville as follows: (1) First, a Base Period ASC that does not reflect the acquisition or loss of ser- vice territory; and (2) Second, a Base Period ASC that incorporates...

  18. ARM TR-008

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Measurement Program September 2004 D.D. Turner, H.E. Revercomb, R.O. Knuteson, R.G. ... and Environmental Research D. D. Turner et al., September 2004, ARM TR-013 ...

  19. VA-s--- ' At&LYTlCAL DATA SHEET

    Office of Legacy Management (LM)

    type respirators and extinguished the fire from oil PH an upwind position. Sample No. ... The smoke No, Ro and fumes resulting from the fire went in the direction of oil PH ' this ...

  20. PLJ3ASE RUSH ANALYTICAL DATA SHEET

    Office of Legacy Management (LM)

    for F U Beta Stamping wrahor8.fm jqtip6 of U heated in 900 P salt No Ro 5 bath. ' :,.a r ' .. ? ' ). ;..- *fhv 11 - n ... .I < Oil 3 PH kmph No. . . , r, . ...

  1. NATIONAL LEAD COMPANY OF OHIO HEALTH AND SAFETY DIVISION - ANALYTICAL...

    Office of Legacy Management (LM)

    AND RADIATION DEPT. ANALYTICAL CHEMISTRY SECT10 AMPLE NOS.: - ROUTE TO1 7 c, U NO:, Oil Bo Cl Beta METHOD OC ANALYSIS: Ro rfae*3 r4tSAAQ. 5 PH DYI Th TSS COVNTINO DATA1 -BKGD ...

  2. SASproperty8_3_09

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    09 Property List for RO Code '13' 1 BARCODE DESCRIPTION MANUF. MODEL COST 0000016386 COMPUTER PERSONAL E4 GATEWAY E4100 P42.4 1,078.38 0000031152 LaCie 2TB Gigabit Et LACIE...

  3. MEMORANDUM TO: FILE

    Office of Legacy Management (LM)

    ... HISTORl' Li.YITELl ST.-ITES .4R.O' 1 I:iSHZ.% TO.- D. C., I985 tion plants. ... and lubri- cants-needed to operate the plants safelv and efficiently with the highly ...

  4. Tomographic

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... which corre- sponds to the first harmonic of the 1, 6 mode poloidal ro- tation ... The appearance of this first harmonic will be explained below by means of a model of SXR ...

  5. June 2014 Most Viewed Documents for Environmental Sciences |...

    Office of Scientific and Technical Information (OSTI)

    Statistical methods for environmental pollution monitoring Gilbert, R.O. (1987) 42 Land ... Study of using oxygen-enriched combustion air for locomotive diesel engines Poola, R.B.; ...

  6. Biodiesel Esla Campos | Open Energy Information

    Open Energy Info (EERE)

    Esla Campos Jump to: navigation, search Name: Biodiesel Esla Campos Place: Spain Product: Company formed to build and own a biodiesel plant at Cabreros del R-o in Spain....

  7. Multi-model mean nitrogen and sulfur deposition from the Atmospheric...

    Office of Scientific and Technical Information (OSTI)

    Authors: Lamarque, J F ; Dentener, F ; McConnell, J ; Ro, C U ; Shaw, M ; Vet, R ; Bergmann, D ; Cameron-Smith, P ; Doherty, R ; Faluvegi, G ; Ghan, S J ; Josse, B ; Lee, T H ; ...

  8. Multi-model mean nitrogen and sulfur deposition from the Atmospheric...

    Office of Scientific and Technical Information (OSTI)

    Authors: Lamarque, J F ; Dentener, F ; McConnell, J ; Ro, C U ; Shaw, M ; Vet, R ; Bergmann, D ; Cameron-Smith, P ; Dalsoren, S ; Doherty, R ; Faluvegi, G ; Ghan, S J ; Josse, B ; ...

  9. CX-012598: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Replace ETP Reverse Osmosis (RO) Cooling Towers (CTWs) and Add a Chemical Addition System CX(s) Applied: B1.5Date: 41827 Location(s): South CarolinaOffices(s): Savannah River Operations Office

  10. Tetrakis-amido high flux membranes

    DOE Patents [OSTI]

    McCray, S.B.

    1989-10-24

    Composite RO membranes of a microporous polymeric support and a polyamide reaction product of a tetrakis-aminomethyl compound and a polyacylhalide are disclosed, said membranes exhibiting high flux and good chlorine resistance.

  11. Tetrakis-amido high flux membranes

    DOE Patents [OSTI]

    McCray, Scott B. (Bend, OR)

    1989-01-01

    Composite RO membranes of a microporous polymeric support and a polyamide reaction product of a tetrakis-aminomethyl compound and a polyacylhalide are disclosed, said membranes exhibiting high flux and good chlorine resistance.

  12. O

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    4 of 23 Ulysses solar wind Coronal Magnetic Field and the Solar Wind Ro Streamer B elt ... he S olar w ind A He 1 00* n alpha n proton A He (%) * What c auses t he v ...

  13. Cost and Performance Comparison Baseline for Fossil Energy Power...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    23 Filtered Water Tank Vertical, cylindrical 1,919,204 liter (507,000 gal) 1 0 24 Makeup Water Demineralizer Multi-media filter, cartridge filter, RO membrane assembly,...

  14. Cost and Performance Baseline for Fossil Energy Plants Volume...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    23 Filtered Water Tank Vertical, cylindrical 1,839,000 liter (486,000 gal) 1 0 24 Makeup Water Demineralizer Multi-media filter, cartridge filter, RO membrane assembly,...

  15. Fernald Environmental Management Project Director's Final Findings...

    Office of Environmental Management (EM)

    ... till, the water table, the upper section oi*the sand and g-ravelaquifer, and the deep ... By: y .& Date q-odi3 ,,;rf,.ea" ,,,... 'i i I Lit: .j ..'c:'; oi(ro,, Director's ...

  16. Microsoft PowerPoint - Overview 5.3.pptx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... Reverse Well - 10 Mgal of Pu-bearing liquid waste discharged directly to GW from 1945-1947 The onl location here P is ro tinel detected in the GW abo e the drinking - The only ...

  17. United States Government Department of Energy Memorandum DATE...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Memorandum DATE: AliNOF: SUBJECT: DEC 2 o 2010 NE-32 Delegation of Acquisition Executive (AE) Authority for the Material Security and Consolidation Project (08-D-702) ro: Richard...

  18. A=8Li (74AJ01)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    cross section, comparable to the geometric value, is understood in terms of the ( + t) cluster nature of 7Li (RO62C). Cross sections for this reaction have recently been...

  19. Microsoft PowerPoint - 13 DOE PM Workshop UPF Presentation revised...

    Broader source: Energy.gov (indexed) [DOE]

    This document has been reviewed by a Y-12 DCUCNI-RO and has been determined to be UNCLASSIFIED and contains no UCNI. This review does not constitute clearance for Public Release. ...

  20. An Evaluation of the Nonlinearity Correction Applied to Atmospheric...

    Office of Scientific and Technical Information (OSTI)

    Authors: Turner, DD ; Revercomb, HE ; Knuteson, RO ; Dedecker, RG ; Feltz, WF Publication Date: 2004-09-01 OSTI Identifier: 1020730 Report Number(s): DOESC-ARMTR-013 PNNL-14922; ...

  1. FY 2011-13 Budget Summary

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    to lock down values of thermal conductivity for WIPP salt for future modeling (from Jordan et al., 2015) 5 Determining thermal conductivity for WIPP Site RoM salt May need ...

  2. DOE/SC-ARM-0606

    Office of Scientific and Technical Information (OSTI)

    ... Tobin,.DC,.H.Revercomb,.RO.Knuteson,.FA.Best,.WL.Smith,.NN.Ciganovich,.RG.Dedecker,.S.Dutc... .Minnis,.P,.L.Nguyen,.W.Smith,.R.Palikonda,.J.Ayers,.D.Doelling,.M.Norde...

  3. Perlick: Order (2011-SE-1401)

    Broader source: Energy.gov [DOE]

    DOE ordered Perlick Corporation to pay a $400 civil penalty after finding Perlick had manufactured and distributed in commerce in the U.S. at least two noncompliant model HP48RO, electric refrigerators.

  4. BPA-2015-01558-FOIA Response

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Unit Transmission Business Line Job: J02902 GS-160 1-13 Manager, District Operations and Maintenance Location Openings The Dalles To: Terrie Jones From: ro..+h4 liofl i 1'S At...

  5. Translation--Final Tank Closure and Waste Management Environmental...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... de Proteccin de Ro P.O. Box 450, Mail Stop H6-60 Richland, WA 99352 TC&WMEIS@saic.com Fax: 509-376-7701 - Telfono: 888-829-6347 Para ver documentos relacionados con el ...

  6. Romania: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    Country Profile Name Romania Population 20,121,641 GDP 191,581,000,000 Energy Consumption 1.68 Quadrillion Btu 2-letter ISO code RO 3-letter ISO code ROU Numeric ISO...

  7. Corn-to-Cellulosic Migration project

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Final report Future work Feed Auger Bone Dry Solid Feed Pretreatment Kettles Solid Feed ... RO Permeate Backset 2 Retentate 37 Scrubber Off Gas 18 Water 38 EtOH Vapor 25 ...

  8. Section 81

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    B.A. Whitney, H.E. Revercomb, R.O. Knuteson, F.A. Best, and W.L. Smith University of ... 1989; Revercomb et al. 1995) and cloud (Smith et al. 1992; Collard et al. 1995) ...

  9. A=16N (1982AJ01)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    82AJ01) (See Energy Level Diagrams for 16N) GENERAL: See also (1977AJ02) and Table 16.4 Table of Energy Levels (in PDF or PS). Model calculations: (1979RO1J, 1980HA35). Reactions...

  10. Scoping Comment Summary 092412.docx

    National Nuclear Security Administration (NNSA)

    Scoping Comment Summary for the Surplus Plutonium Disposition Supplemental Environmental Impact Statement U.S. Department of Energy, National Nuclear Security Administration, and Tennessee Valley Authority Since announcement of the Surplus Plutonium Disposition Supplemental Environmental Impact Statement (SPD Supplemental EIS), DOE has provided three opportunities for the public to provide scoping comments (2007 [72 FR 14543]; 2010 [75 FR 41850]; and 2012 [77 FR 1920]). The public scoping

  11. CRAD, NNSA - Federal Employee Training and Qualification Program...

    Office of Environmental Management (EM)

    & Publications CRAD, NNSA - Facility Representatives (FR) Technical Qualification Program Self-Assessment Report - NNSA Production Office - 2014 CRAD, NNSA - Contractor Training...

  12. 3Q CY2007 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Broader source: Energy.gov [DOE]

    Attached is the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period from July to September 2007. Data for these indicators are gathered by Field...

  13. 10 C.F.R. PART 835-OCCUPATIONAL RADIATION PROTECTION, Subpart...

    Energy Savers [EERE]

    835-OCCUPATIONAL RADIATION PROTECTION Authority: 42 U.S.C. 2201; 7191. Source: 58 FR ... The rules in this part establish radiation protection standards, limits, and program ...

  14. Super Heavy Nuclei

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Institut fr Kernchemie * Target materials * Backing characterization * Production techniques - Molecular Plating * Target characterization * Target performance Fabrica'on a nd c ...

  15. 2Q CY2005 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Office of Energy Efficiency and Renewable Energy (EERE)

    Attached is the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period from April to June 2005. Data for these indicators are gathered by Field elements...

  16. 3Q CY2005 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Broader source: Energy.gov [DOE]

    Attached is the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period from July to September 2005. Data for these indicators are gathered by Field...

  17. 1Q CY2012 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Broader source: Energy.gov [DOE]

    This memorandum summarizes the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period from January through March 2012. Data for these indicators were...

  18. 4Q CY2005 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Office of Energy Efficiency and Renewable Energy (EERE)

    Attached is the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period from October to December 2005. Data for these indicators are gathered by Field...

  19. 4Q CY2010 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Office of Energy Efficiency and Renewable Energy (EERE)

    "This memorandum summarizes the highlights of the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period October through December 2010. Data for these...

  20. 2Q CY2007 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Office of Energy Efficiency and Renewable Energy (EERE)

    Attached is the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period from April to June 2007. Data for these indicators are gathered by field elements...

  1. 1Q CY2007 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Office of Energy Efficiency and Renewable Energy (EERE)

    Attached is the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period from January to March 2007. Data for these indicators are gathered by Field elements...

  2. 3Q CY2010 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Broader source: Energy.gov [DOE]

    This memorandum summarizes the highlights of the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period of July through September 2010. Data for these...

  3. 4Q CY2011 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Broader source: Energy.gov [DOE]

    "This memorandum summarizes the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period from October through December 2011. Data for these indicators were...

  4. 3Q CY2006 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Broader source: Energy.gov [DOE]

    Attached is the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period from July to September 2006. Data for these indicators are gathered by Field...

  5. 4Q CY2006 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Office of Energy Efficiency and Renewable Energy (EERE)

    Attached is the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period from October to December 2006. Data for these indicators are gathered by Field...

  6. 1Q CY2005 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Broader source: Energy.gov [DOE]

    Attached is the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period from January to March 2005. Data for these indicators are gathered by Field elements...

  7. 2Q CY2011 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Office of Energy Efficiency and Renewable Energy (EERE)

    "This memorandum summarizes the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period April through June 20 1 1. Data for these indicators were gathered...

  8. 1Q CY2011 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Broader source: Energy.gov [DOE]

    This memorandum summarizes the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the Period January through March 2011. Data for these indicators were gathered...

  9. 2Q CY2012 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Office of Energy Efficiency and Renewable Energy (EERE)

    "This memorandum summarizes the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period from April through June 2012. Data for these indicators were...

  10. 3Q CY2011 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Broader source: Energy.gov [DOE]

    This memorandum summarizes the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the Period July  through September 2011. Data for these indicators were gathered...

  11. 2Q CY2010 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Office of Energy Efficiency and Renewable Energy (EERE)

    This memorandum summarizes the highlight of, and announces the availablity on-line of, the Facility Representative (FR) Program Performance Indicators are gathered by Field elements quarterly per...

  12. 4Q CY2007 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Office of Energy Efficiency and Renewable Energy (EERE)

    "Attached is the Facility Representative (FR) Program Performance Indicators QuarterlyReport covering the period from October to December 2007. Data for these indicators aregathered by Field...

  13. 2Q CY2006 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Office of Energy Efficiency and Renewable Energy (EERE)

    Attached is the Facility Representative (FR) Program Performance Indicators Quarterly Report covering the period from April to June 2006. Data for these indicators are gathered by Field elements...

  14. Notices

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    C. Conaty, Acting Director, Office of English Language Acquisition, Language Enhancement, and Academic Achievement for Limited English Proficient Students. FR Doc. 2013-21639 ...

  15. EIS-0422: EPA Notice of Availability of the Draft Environmental...

    Broader source: Energy.gov (indexed) [DOE]

    DOEEIS-0422 (July 2010 - 75 FR 38517) More Documents & Publications EIS-0403-S1: EPA Notice of Availability of the Supplement to the Draft Programmatic Environmental...

  16. EIS-0385: Notice of Intent to Prepare an Environmental Impact...

    Broader source: Energy.gov (indexed) [DOE]

    Reserve (DOEEIS-0385) (090105)(70FR52088) More Documents & Publications EIS-0385-S1: Notice of Intent to Prepare a Supplemental Environmental Impact Statement and Conduct...

  17. Pending Applications | Department of Energy

    Office of Environmental Management (EM)

    Regulation Pending Applications Pending Applications Pending Export Authorization Applications: To Mexico: EA-401 Lonestar Power Marketing LLC (FR Notice) Applied 05222014 ...

  18. Spencer Chetnical Ccmpny

    Office of Legacy Management (LM)

    to unrestricted areas. " with: respect to air- borne radioactivity. . . ..i .' .' 2. ... 1960.. .:,: : . . . . .. .-Lc*. .Bxhawt. air fr&,'& ho&in- R&n 16 of. .) -Buildiof,702 ...

  19. Notice of Availability of a Preliminary List of Standby Power...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    and Testing Guidelines, Federal Register, 66 FR 67517, December 31, 2001 Notice of Availability of a Preliminary List of Standby Power Products and Testing Guidelines, Federal ...

  20. Mexico Sectoral Study on Climate and Refrigeration Technology...

    Open Energy Info (EERE)

    Market analysis Website http:www.giz.deen Program Start 2010 Program End 2012 Country Mexico Central America References Deutsche Gesellschaft fr Internationale Zusammenarbeit...

  1. EIS-0238: Withdrawal of Notice of Intent to Prepare an Environmental...

    Broader source: Energy.gov (indexed) [DOE]

    Proposed Minnesota Agri-Power Plant and Associated Facilities On October 7, 1998 (63 FR ... facility, known as the Minnesota Agri- Power Plant (MAPP), and associated transmission ...

  2. EIS-0284: EPA Notice of Availability of the Draft Environmental...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Operation of a 91-Megawatt Electric Power Plant, Elkhart, Logan County, Illinois DOE... Operation of a 91-Megawatt Electric Power Plant, Elkhart, Logan County, Illinois, 69 FR ...

  3. SC e-journals, Medicine

    Office of Scientific and Technical Information (OSTI)

    ... Trends in Microbiology Veterinary Research Communications Virchows Archiv Virology Virtual Journal of Biomedical Optics Virus Genes X-Ray Spectrometry Zeitschrift fr Kardiologie

  4. Workforce Analysis and Staffing | Department of Energy

    Energy Savers [EERE]

    FR Staffing Process See Appendix C in DOE-STD-1063-2011, Facility Representatives ... Nuclear Safety Facility Safety Security Classification Databases Dashboards DOE Technical ...

  5. Notices

    Broader source: Energy.gov (indexed) [DOE]

    May 29, 2013. Michael K. Yudin, Delegated the authority to perform the functions and duties of the Assistant Secretary for Special Education and Rehabilitative Services. FR...

  6. Ukraine-GTZ Climate Oriented Mobility | Open Energy Information

    Open Energy Info (EERE)

    Deutsche Gesellschaft fr Internationale Zusammenarbeit (GIZ) GmbH Partner German Federal Ministry for Economic Cooperation and Development (BMZ) Sector Energy Focus...

  7. p-Type transparent conducting oxides and methods for preparation...

    Office of Scientific and Technical Information (OSTI)

    Inventors: Shahriari, Dean Y. 1 ; Barnabe, Antoine 2 ; Mason, Thomas O. 1 ; Poeppelmeier, Kenneth R. 1 + Show Author Affiliations (Evanston, IL) (Toulouse, FR) Issue Date: ...

  8. Application for Presidential Permit OE Docket No. PP-387 Soule River Hydroelectric Project; Federal Register Notice, Volume 78, No. 154- Aug. 9, 2013: Correction

    Broader source: Energy.gov [DOE]

    The Department of Energy corrects a Notice of Application published in the Federal Register (76 FR 50726) on July 30, 2013,

  9. On Line Journals - Links - Cyclotron Institute

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Letters B Nuclear Instruments and Methods in Physics Research A Nuclear Instruments and Methods in Physics Research B Springer Physics and Astronomy Zeitschrift fr Physik A...

  10. DOE Publishes Notice of Proposed Rulemaking for Commercial Refrigerati...

    Broader source: Energy.gov (indexed) [DOE]

    test procedures for commercial refrigeration equipment. 78 FR 64295 (October 28, 2013). Find more information on the rulemaking, including milestones, statutory authority,...

  11. Mexico-NAMA Programme | Open Energy Information

    Open Energy Info (EERE)

    Mexico-NAMA Programme (Redirected from GIZ-Mexico NAMA Programme) Jump to: navigation, search Name GIZ-Mexico NAMA Programme AgencyCompany Organization Deutsche Gesellschaft fr...

  12. USAJobs Search | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Supervisory Accountant Job Summary: This position is located in the Federal Partner Accounting (FRF) organization of Accounting and Reporting (FR), Finance (F), Bonneville Power...

  13. EIS-0367: Notice of Intent to Prepare an Environmental Impact...

    Broader source: Energy.gov (indexed) [DOE]

    Transmission Policy-Level Environmental Impact Statement, DOEEIS-0367 (December 2003 - 68 FR 71101) More Documents & Publications EIS-0374: Notice of Intent to Prepare an...

  14. EIS-0358: Notice of Intent to Prepare an Environmental Impact...

    Broader source: Energy.gov (indexed) [DOE]

    Wellton-Mohawk Generating Facility, Yuma County, Arizona, EIS-0358 May 19, 2003 (68 FR 27056) More Documents & Publications CX-004898: Categorical Exclusion Determination...

  15. Notice of Intent to Prepare an Environmental Impact Statement...

    Broader source: Energy.gov (indexed) [DOE]

    conversion facilities, at Portsmouth, Ohio, and Paducah, Kentucky. On April 28, 2003 (68 FR 22368), DOE announced its intent to prepare two separate EISs, one for each facility....

  16. COLLOQUIUM: Wendelstein 7-X: Highlights from the First Operational...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    COLLOQUIUM: Wendelstein 7-X: Highlights from the First Operational Phase of the New Optimized Stellarator Dr. Oliver P. Ford Max-Planck Institut fr Plasmaphysik, Greifswald...

  17. EIS-0357: EPA Notice of Availability of the Final Environmental...

    Broader source: Energy.gov (indexed) [DOE]

    Gilberton Coal-to-Clean Fuels and Power Project, DOEEIS-0357 (November 2007) 72 FR 62229 More Documents & Publications EIS-0394: EPA Notice of Availability of the Draft...

  18. Verification of the ideal magnetohydrodynamic response at rational...

    Office of Scientific and Technical Information (OSTI)

    New Jersey 08543, USA Max-Planck-Institut fr Plasmaphysik, Greifswald 17491, Germany Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, USA Publication Date:...

  19. Convention on Supplementary Compensation for Nuclear Damage Contingent...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of the Energy Independence and Security Act of 2007. PDF icon FR CSC NOPR More Documents & Publications Convention on Supplementary Compensation Rulemaking NOPR Fluor NOPR Exelon...

  20. DOE STANDARD - Draft DOE-STD-1063-XXXX, FACILITY REPRESENTATIVES

    Energy Savers [EERE]

    ... HJ5: Perform a keyword search and replace all ... order for individuals to enter an FR training and ... scientific principles and communicate in technical terms. ...

  1. Supervisory Accountant

    Broader source: Energy.gov [DOE]

    This position is located in the General Accounting (FRG) organization of Accounting and Reporting (FR), Finance Office (F), Bonneville Power Administration. Accounting and Reporting provides...

  2. DOE Publishes Petition of CSA Group for Classification as a Nationally...

    Broader source: Energy.gov (indexed) [DOE]

    notice of petition and request for public comments regarding CSA Group for classification as a nationally recognized certification program for small electric motors. 78 FR...

  3. Enterprise Assessments Review of Radioactive Waste Management...

    Broader source: Energy.gov (indexed) [DOE]

    ... FR Facility Representative FUEF Former Uranium Enrichment Facilities FY Fiscal Year GDP ... System NDA Non-Destructive Assay NNSS Nevada National Security Site NRR Noise ...

  4. Taking pictures with protons

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ring accelerator of the GSI Helmholtzzentrum fr Schwerionenforschung GmbH in Germany. ... U.S., German, Russian collaboration conducts first experiments in Germany LOS ALAMOS, ...

  5. Microsoft Word - SWCN.doc

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Permanent address: Lehrstuhl fr Physikalische Chemie II, Universitt Erlangen-Nrnberg, Egerlandstr. 3, D- 91058 Erlangen, Germany Science Highlight - January 2006 ...

  6. Water Resources Council FLOODPLAIN MANAGEMENT GUIDELINES For...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water Resources Council FLOODPLAIN MANAGEMENT GUIDELINES For Implementing E.O. 11988 43 FR 6030 February 10, 1978 (Second Reprinting) i- ' 1': : 8410-01 WATER RESOURCES COUNCIL...

  7. Public Comment re NOI on Convention on Supplementary Compensation...

    Office of Environmental Management (EM)

    Convention on Supplementary Compensation for Nuclear Damage Contingent Cost Allocation -75 FR 43945 PDF icon Public Comment re NOI on Convention on Supplementary Compensation for...

  8. EA-1916: DOE Notice of Availability of a Draft Environmental...

    Broader source: Energy.gov (indexed) [DOE]

    and the Federal Energy Regulatory Commission's (Commission or FERC's) regulations, 18 CFR Part 380 (Order No. 486, 52 FR 47897), the Office of Energy Projects has reviewed Ocean...

  9. EIS-0445: DOE Notice of Availability of the Draft Environmental...

    Broader source: Energy.gov (indexed) [DOE]

    of the Draft Environmental Impact Statement for the Mountaineer Commercial Scale Carbon Capture and Storage Project, Mason County, West Virginia, DOEEIS-0445 (March 2011 - 76 FR...

  10. Department of Energy Information Quality Guidelines | Department...

    Broader source: Energy.gov (indexed) [DOE]

    OMB guidelines, published in the Federal Register on February 22, 2002 (67 FR 8452), direct agencies to issue their own implementing guidelines that include administrative...

  11. Browse by Discipline -- E-print Network Subject Pathways: Power...

    Office of Scientific and Technical Information (OSTI)

    Werner (Werner Aeschbach-Hertig) - Institut fr Umweltphysik, Universitt Heidelberg Afton, Alan D. (Alan D. Afton) - Louisiana Cooperative Fish and Wildlife Research Unit. ...

  12. Browse by Discipline -- E-print Network Subject Pathways: Environmenta...

    Office of Scientific and Technical Information (OSTI)

    Werner (Werner Aeschbach-Hertig) - Institut fr Umweltphysik, Universitt Heidelberg Afton, Alan D. (Alan D. Afton) - Louisiana Cooperative Fish and Wildlife Research Unit. ...

  13. Engstrom, Suyama, Vanni, Mattson, Serres, Cimon, Leckband Page 1 of 3

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    RI/FS and Proposed Plan, 100-F, Draft A, v.1 Engstrom, Suyama, Vanni, Mattson, Serres, Cimon, Leckband Page 1 of 3 Draft Advice re: Remedial Investigation/Feasibility Study and Proposed Plan for Remediation of the 100-FR-1, 100-FR-2, 100-FR-3, 100-IU-2, and 100-IU-6 Operable Units, Draft A Background The Hanford Advisory Board (Board) appreciates the opportunity to provide comments and advice for the Remedial Investigation/Feasibility Study and Proposed Plan for Remediation of the 100-FR-1,

  14. Public Comment re NOI on Convention on Supplementary Compensation for Nuclear Damage

    Broader source: Energy.gov [DOE]

    ENERGYSOLUTIONS' Comment in Response to Notice of Inquiry, Convention on Supplementary Compensation for Nuclear Damage Contingent Cost Allocation -75 FR 43945

  15. Laboratoire de Météorologie Dynamique, Ecole Polytechnique...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Cedex, France * Corresponding author : jean-charles.dupont@lmd.polytechnique.fr 1. Introduction Jean-Charles Dupont *1 , Martial Haeffelin 2 2. Climatologies of AOT, IWV, SW ...

  16. Mr. Pusch is geologist at the Federal Institute for Geosciences...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Federal Institute for Geosciences and Natural Resources (BGR) in Hannover. He studied geology (2004 - 2009) at the Lehrstuhl fr Ingenieurgeologie & Fachgebiet Tektonik und...

  17. EIS-0287: Amended Record of Decision | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Record of Decision: Idaho High-Level Waste and Facilities Disposition Final Environmental Impact Statement EIS-0287 (November 2006) (71 FR 68811) More Documents & Publications...

  18. Revisions to FAR Part 17 Special Contracting Methods and Part...

    Broader source: Energy.gov (indexed) [DOE]

    and Assistance Management SUBJECT: Revisions to FAR Part 17 Special Contracting Methods and Part 35 Research and Development Contracting SUMMARY: The Federal Register (77 FR...

  19. Completed EISs

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Number Title Prog Office Ops Office Federal Register Notices Notice Date Citation Agency Fourmile Hill Geothermal Development Project BPA DOEEIS-0266 661996 BLM 61 FR 28887 NOI ...

  20. EIS-0441: Amended Notice of Availability of a Draft Environmental...

    Broader source: Energy.gov (indexed) [DOE]

    issued on April 27, 2012, (77 FR 25165), changing the state from Colorado to Arizona. EIS-0441-EPAAmendedNOADEIS-2012.pdf More Documents & Publications EIS-0385: EPA...

  1. Microsoft PowerPoint - ANL Process Monitoring NEET Webinar.pptx

    Broader source: Energy.gov (indexed) [DOE]

    Electrochemical Processing of Used Fuel J. L. Willit (willit@anl.gov) Argonne National Laboratory Introduction Principles followed in establishing the used LWR & FR fuel treatment ...

  2. EIS-0385-S1: Notice of Intent to Prepare a Supplemental Environmental...

    Broader source: Energy.gov (indexed) [DOE]

    Impact Statement and Conduct Public Scoping Meetings, and Notice of Floodplain and Wetlands Involvement, 73 FR 11895 (March 2008) More Documents & Publications EIS-0385-S1:...

  3. EIS-0361: Notice of Intent to Prepare an Environmental Impact...

    Broader source: Energy.gov (indexed) [DOE]

    Co-Production Demonstration Project, Rainelle, West Virgina and Notice of FloodplainWetlands Involvement (June 2003) (68 FR 33111) More Documents & Publications EIS-0361: Draft...

  4. EIS-0445: Notice of Intent to Prepare an Environmental Impact...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Intent to Prepare an Environmental Impact Statement and Potential Floodplain and Wetlands Involvement, EIS-0445 (June 2010) (75 FR 32171) More Documents & Publications...

  5. Office of Enterprise Assessments Targeted Review of Radiological...

    Broader source: Energy.gov (indexed) [DOE]

    and Repair Area EA DOE Office of Enterprise Assessments EPD Electronic Pocket Dosimeter ESDH Environment, Safety and Health Division ES&H Environment, Safety and Health FR...

  6. Notices

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Kate Mullan, Acting Director, Information Collection Clearance Division, Privacy, Information and Records Management Services, Office of Management. FR Doc. 2013-19294 Filed ...

  7. Notices

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Dated: May 6, 2014. Tomakie Washington, Acting Director, Information Collection Clearance Division, Privacy, Information and Records Management Services, Office of Management. FR ...

  8. Haiti-Low-Carbon Energy Roadmaps for the Greater Antilles | Open...

    Open Energy Info (EERE)

    Institute Partner Deutsche Gesellschaft fr Internationale Zusammenarbeit (GIZ) GmbH, National Energy Commission Sector Climate, Energy Focus Area Economic Development,...

  9. Dominican Republic-Low-Carbon Energy Roadmaps for the Greater...

    Open Energy Info (EERE)

    Institute Partner Deutsche Gesellschaft fr Internationale Zusammenarbeit (GIZ) GmbH, National Energy Commission Sector Climate, Energy Focus Area Economic Development,...

  10. Jamaica-Low-Carbon Energy Roadmaps for the Greater Antilles ...

    Open Energy Info (EERE)

    Institute Partner Deutsche Gesellschaft fr Internationale Zusammenarbeit (GIZ) GmbH, National Energy Commission Sector Climate, Energy Focus Area Economic Development,...

  11. Browse by Discipline -- E-print Network Subject Pathways: Environmenta...

    Office of Scientific and Technical Information (OSTI)

    X Y Z Weber, Harald (Harald Weber) - Fakultt fr Informatik und Elektrotechnik, Universitt Rostock Wehenkel, Louis (Louis Wehenkel) - Dpartement d'Electricit, Electronique ...

  12. Federal Acquisition Circular 2005-61

    Broader source: Energy.gov [DOE]

    Attached for your information is a list and summary of FAR amendments published in the September 13, 2012 Federal Register at 77 FR 56738.

  13. Federal Acquisition Circular 2005-63

    Broader source: Energy.gov [DOE]

    The Federal Acquisition Regulation (FAR) amendment published in the December 10, 2012 Federal Register at 77 FR 73516 implements FAR Case 2012–030 Iran Threat Reduction.

  14. 2Q CY2008 (PDF), Facility Representative Program Performance Indicators Quarterly Report

    Broader source: Energy.gov [DOE]

    Attached is the Facility Representative (FR) Program Performance Indicators QuarterlyReport covering the period from April to June 2008. Data for these indicators aregathered by Field elements...

  15. EIS-0310: Record of Decision

    Office of Energy Efficiency and Renewable Energy (EERE)

    Programmatic Environmental Impact Statement for Accomplishing Expanded Civilian Nuclear Energy Research and Development and Isotope Production Missions in the United States, EIS-0310 (January 2001) (66 FR 7877)

  16. EIS-0249: Record of Decision (September 1996) | Department of...

    Energy Savers [EERE]

    DOEEIS-0249 (September 1996) 61 FR 48921 More Documents & Publications EIS-0281-SA-01: Supplemental Analysis EA-1954: Draft Environmental Assessment EIS-0281: Draft ...

  17. EIS-0229: Record of Decision (November 2003) | Department of...

    Energy Savers [EERE]

    68 FR 64611 (January 1997) More Documents & Publications EIS-0283: Amended Record of Decision EIS-0229-SA-03: Supplement Analysis EIS-0283: Final Environmental Impact Statement

  18. Federal Acquisition Circular 2005-60

    Broader source: Energy.gov [DOE]

    Attached for your information is a list and summary of FAR amendments published in the July 26, 2012 Federal Register at 77 FR 44045.

  19. Federal Acquisition Circular 2005-59

    Broader source: Energy.gov [DOE]

    Attached for your information is a list of FAR amendments published in the May 10, 2012 Federal Register at 77 FR 27546.

  20. Federal Acquisition Circular 2005-54

    Broader source: Energy.gov [DOE]

    Attached for your information is a list of FAR amendments published in today's Federal Register (76 FR 68027, November 2, 2011).

  1. Federal Acquisition Circular 2005-48

    Broader source: Energy.gov [DOE]

    Federal Acquisition Circular 2005-48 was issued December 30, 2010, 75 FR 82565. It concludes 4 separate rulemakings which are described in the attached summary sheet.

  2. Enterprise Assessments Targeted Review of Work Planning and Control...

    Broader source: Energy.gov (indexed) [DOE]

    Management EPC Engineering, Projects, and Construction ESQ Environmental Safety and Quality FR Facility Representative FWS Field Work Supervisor FY Fiscal Year GHA General...

  3. EIS-0403: EPA Notice of Availability of the Draft Programmatic...

    Broader source: Energy.gov (indexed) [DOE]

    States. Notice of Availability, Draft Environmental Impact Statement: Programmatic-Bureau of Land Management Solar Energy Program, DOEEIS-0403 (December 2010 - 75 FR 78992)...

  4. Browse by Discipline -- E-print Network Subject Pathways: Computer...

    Office of Scientific and Technical Information (OSTI)

    ... (M.J. de la Puente) - Departamento de lgebra, Universidad Complutense de Madrid de la ... Richard (Richard Dipper) - Institut fr Algebra und Zahlentheorie, Universitt Stuttgart ...

  5. EUROS Entwicklungsgesellschaft f r Windkraftanlagen mbH | Open...

    Open Energy Info (EERE)

    fr Windkraftanlagen mbH Place: Berlin, Germany Zip: 13088 Sector: Wind energy Product: Berlin-based wind turbine blade maker with a production base in Poland....

  6. U.S. DEPARTMENT OF ENERGY ENVIRONMENTAL ...

    Office of Environmental Management (EM)

    Jeffrey Dorman Rachel Rosenthal, GC-51 Electricity Delivery and Energy Reliability Hawaii Clean Energy Programmatic EIS NOI (75 FR 77859). Scoping meetings held in Honolulu,...

  7. Webinar: Energy Conservation Standards for Dehumidifiers; Availability of the Preliminary Technical Support Document

    Broader source: Energy.gov [DOE]

    DOE is conducting a public meeting and webinar for the availability of the preliminary technical support document regarding energy conservation standards for residential dehumidifiers. 79 FR 29380 ...

  8. EIS-0425: EPA Notice of Availability of Draft Environmental Impact...

    Broader source: Energy.gov (indexed) [DOE]

    Notice of Availability of Draft Environmental Impact Statement for the Mid-Columbia Coho Restoration Program, DOEEIS-0425 (June 2011 - 76 FR 37111) More Documents & Publications...

  9. Federal Acquisition Circular 2005-47

    Broader source: Energy.gov [DOE]

    Federal Acquisition Circular 2005-47 was issued December 13, 2010, 75 FR 77721. It concludes 7 separate rulemakings which are described in the attached summary sheet.

  10. France: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    Country Profile Name France Population Unavailable GDP Unavailable Energy Consumption 11.29 Quadrillion Btu 2-letter ISO code FR 3-letter ISO code FRA Numeric ISO...

  11. Notice of Reestablishment of the Electricity Advisory Committee

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Office of Policy and International Affairs. FR Doc. ... of duties imposed upon the Department of Energy by law. ... L. 92-463), the General Services Administration Final Rule ...

  12. Federal Acquisition Circular 2005-62

    Broader source: Energy.gov [DOE]

    Attached for your information is a list and summary of FAR amendments published in the November 20, 2012 Federal Register at 77 FR 69714.

  13. Microsoft Word - RPP-PLAN-47325 Rev 0.docx

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Regulations CMS IP Corrective Measures Study Implementation Plan DOE U.S. Department of Energy FR Federal Register HFFACO Hanford Federal Facility Agreement and Consent Order HLW...

  14. Designing a biocidal reverse osmosis membrane coating: Synthesis and biofouling properties

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Hibbs, Michael R.; McGrath, Lucas K.; Kang, Seoktae; Adout, Atar; Altman, Susan J.; Elimelech, Menachem; Cornelius, Chris J.

    2015-12-04

    In this study, a biocidal coating was developed in order to reduce biofouling on a reverse osmosis (RO) membrane using a quaternary ammonium (QA) functionalized polymer. The synthesis of a series of polysulfone (PS) ionomers with QA groups is described, and a method for spraying these QA ionomers as an alcoholic solution, which dried into water insoluble coatings. Contact angle and streaming potential were used to analyze the coating's hydrophilicity and surface charge. Both PS-QA1 and the commercial RO membrane had an apparent contact angle of 68° that increased to 126° for PS-QA12 corresponding to alkyl chain length. A negativelymore » charged particle-probe was used to measure coated and uncoated RO membrane interaction forces. Measured interaction forces correlated strongly with the length of alkyl chains or hydrophobicity of the coated surfaces. Uncoated RO membranes and ones coated with PS-QA were exposed to suspensions of Escherichia coli cells. All four PS-QA coatings showed significant biotoxicity and killed 100% of the E. coli cells, but uncoated RO membranes had metabolically active biofilms. However, coatings tested in a RO crossflow system showed a flux reduction that is attributed to mass transfer resistance due to excessively thick films.« less

  15. Designing a biocidal reverse osmosis membrane coating: Synthesis and biofouling properties

    SciTech Connect (OSTI)

    Hibbs, Michael R.; McGrath, Lucas K.; Kang, Seoktae; Adout, Atar; Altman, Susan J.; Elimelech, Menachem; Cornelius, Chris J.

    2015-12-04

    In this study, a biocidal coating was developed in order to reduce biofouling on a reverse osmosis (RO) membrane using a quaternary ammonium (QA) functionalized polymer. The synthesis of a series of polysulfone (PS) ionomers with QA groups is described, and a method for spraying these QA ionomers as an alcoholic solution, which dried into water insoluble coatings. Contact angle and streaming potential were used to analyze the coating's hydrophilicity and surface charge. Both PS-QA1 and the commercial RO membrane had an apparent contact angle of 68° that increased to 126° for PS-QA12 corresponding to alkyl chain length. A negatively charged particle-probe was used to measure coated and uncoated RO membrane interaction forces. Measured interaction forces correlated strongly with the length of alkyl chains or hydrophobicity of the coated surfaces. Uncoated RO membranes and ones coated with PS-QA were exposed to suspensions of Escherichia coli cells. All four PS-QA coatings showed significant biotoxicity and killed 100% of the E. coli cells, but uncoated RO membranes had metabolically active biofilms. However, coatings tested in a RO crossflow system showed a flux reduction that is attributed to mass transfer resistance due to excessively thick films.

  16. Data Collection for Current U.S. Wind Energy Projects: Component Costs, Financing, Operations, and Maintenance; January 2011 - September 2011

    SciTech Connect (OSTI)

    Martin-Tretton, M.; Reha, M.; Drunsic, M.; Keim, M.

    2012-01-01

    DNV Renewables (USA) Inc. (DNV) used an Operations and Maintenance (O&M) Cost Model to evaluate ten distinct cost scenarios encountered under variations in wind turbine component failure rates. The analysis considers: (1) a Reference Scenario using the default part failure rates within the O&M Cost Model, (2) High Failure Rate Scenarios that increase the failure rates of three major components (blades, gearboxes, and generators) individually, (3) 100% Replacement Scenarios that model full replacement of these components over a 20 year operating life, and (4) Serial Failure Scenarios that model full replacement of blades, gearboxes, and generators in years 4 to 6 of the wind project. DNV selected these scenarios to represent a broad range of possible operational experiences. Also in this report, DNV summarizes the predominant financing arrangements used to develop wind energy projects over the past several years and provides summary data on various financial metrics describing those arrangements.

  17. Increased radiation dose at mammography due to prolonged exposure, delayed processing, and increased film darkening

    SciTech Connect (OSTI)

    Kimme-Smith, C.; Bassett, L.W.; Gold, R.H.; Chow, S. )

    1991-02-01

    Four single-emulsion films introduced over the past 2 years--Du Pont Microvision, Fuji MiMa, Konica CM, and Eastman Kodak OM--were compared with Eastman Kodak OM SO-177 (Min-RE) film to evaluate their varying effects on mean glandular dose of reciprocity law failure due to prolonged exposure, delayed processing, and increased film darkening as a result of increased radiation exposure to improve penetration of glandular tissue. Exposures over 1.3 seconds led to increased radiation doses of 20%-30%. Delays in processing of 6 hours decreased processing speed by 11%-32% for all films except Du Pont Microvision. Optical density increases of 0.40 required 20%-30% more skin exposure for all five films. Optimal viewing densities were also evaluated and found to be different for each of the five films. Mammographers need to be aware of these differences in mammographic films to achieve maximum contrast at mammography.

  18. Realization of optical bistability and multistability in Landau-quantized graphene

    SciTech Connect (OSTI)

    Hamedi, H. R.; Asadpour, S. H.

    2015-05-14

    The solution of input-output curves in an optical ring cavity containing Landau-quantized graphene is theoretically investigated taking the advantage of density-matrix method. It is found that under the action of strong magnetic and infrared laser fields, one can efficiently reduce the threshold of the onset of optical bistability (OB) at resonance condition. At non-resonance condition, we observed that graphene metamaterial can support the possibility to obtain optical multistability (OM), which is more practical in all-optical switching or coding elements. We present an analytical approach to elucidate our simulations. Due to very high infrared optical nonlinearity of graphene stemming from very unique and unusual properties of quantized Landau levels near the Dirac point, such controllability on OB and OM may provide new technological possibilities in solid state quantum information science.

  19. Operations and Maintenance Concept Plan for the Immobilized High Level Waste (IHLW) Interim Storage Facility

    SciTech Connect (OSTI)

    JANIN, L.F.

    2000-08-30

    This O&M Concept looks at the future operations and maintenance of the IHLW/CSB interim storage facility. It defines the overall strategy, objectives, and functional requirements for the portion of the building to be utilized by Project W-464. The concept supports the tasks of safety basis planning, risk mitigation, alternative analysis, decision making, etc. and will be updated as required to support the evolving design.

  20. DE-SOL-0000332 ApplicableDocuments | netl.doe.gov

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Electronic Reading Room Site Support Contractor Solicitation DE-SOL-0000332 - Support Administrative Services (SAS) Applicable Documents Financial Management Division (FMD) Support Service Area U.S. Department of Energy Accounting Handbook Automated Standard Application for Payment (ASAP) U.S. General Services Administration Federal Travel Regulation (FTR) U.S. Department of Energy Policy and Procedures Office Management (OM) Support Service Area NETL Correspondence Guidelines [PDF-1.1MB]