Powered by Deep Web Technologies
Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

Electric lighting constitutes approximately 21-23 % of the electric grid load in the United States. The higher energy and maintenance costs of incandescent lamps, combined with the favorable economics of high-efficiency compact fluorescent lamps (CFLs), are making CFLs the increasingly popular choice for both residential and commercial lighting. Utility incentive and rebate programs to stimulate CFL use and the beginnings of a ban on incandescent lamps are enhancing CFL penetration levels in these enviro...

2009-12-17T23:59:59.000Z

2

Electronic Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This EPRI Technical Update addresses the fastest growing energy efficient light source the electronic compact fluorescent lamp (CFL). Business and technical market factors (Chapter 2) explain the past and future growth of the CFL market while emphasizing future technical improvements along with discussion of the importance of utility involvement in helping their customers make the switch from incandescent lamps to CFLs. The basic CFL technology is covered in Chapter 3 including test results for selected ...

2007-12-18T23:59:59.000Z

3

Magnetic fluorescent lamp  

DOE Patents (OSTI)

The radiant emission of a mercury-argon discharge in a fluorescent lamp assembly is enhanced by providing means for establishing a magnetic field with lines of force along the path of electron flow through the bulb of the lamp assembly, to provide Zeeman splitting of the ultraviolet spectral line. Optimum results are obtained when the magnetic field strength causes a Zeeman splitting of approximately 1.7 times the thermal line width.

Berman, S.M.; Richardson R.W.

1983-12-29T23:59:59.000Z

4

Fluorescent lamp ballast  

SciTech Connect

An electronic ballast is described having at least a first and second terminal for engaging the filaments of at least one fluorescent lamp which requires a breakdown voltage to ignite the lamp and a maintaining voltage for maintaining ionization therewithin, the electronic ballast comprising: a direct current voltage source; a transistor; a transformer having a primary winding separated into a first winding, a second winding, a third winding, and a fourth winding; the first winding connected between the voltage source and the first terminal; the second winding connected between the two terminals; the third winding connected between the second terminal and to both the transistor and to ground; the fourth winding connected between ground and the transistor; the lamp being parallel to the second winding when the lamp filaments engages the ballast terminals.

Ureche, A.

1987-08-25T23:59:59.000Z

5

Fluorescent lamp ballast  

SciTech Connect

This patent describes an electronic ballast unit for a fluorescent lamp comprising: a circuit assembly having a pair of voltage input terminal and a first inductor and a capacitor in series relationship with each other to form a series resonant circuit. The circuit is adapted to be coupled to a fluorescent lamp to provide a starting voltage for the lamp; and a second inductor connected in shunt relationship to the first inductor and connected to the other input terminal. There is a core on which the first inductor and the second inductor are mounted. The core inductively couples the inductors with each other and are shaped to reduce core losses to minimize the increase of temperature of the core; the core is of a generally H-shaped configuration, and means of opposite ends of the H-shaped core to complete the magnetic flux path for each inductor, respectively.

Boyd, G.D.

1987-03-31T23:59:59.000Z

6

Flash Lighting with Fluorescent Lamp.  

E-Print Network (OSTI)

??A flash lighting circuit with the fluorescent lamp is designed to produce lighting flicker by means of controlling the operating frequency and the duty-ratio of… (more)

Hsieh, Horng

2005-01-01T23:59:59.000Z

7

Fluorescent lamp dimming adaptor kit  

SciTech Connect

An add-on fluorescent lamp dimming adaptor is described for connecting to a conventional nondimming ballast in a fluorescent lighting system, the system including a source of ac voltage. The ballast has terminals for connecting to a fluorescent lamp, the adaptor comprising: a switching module adapted to be coupled to the terminals for switching current from the lamp, the switching module being connected in parallel with the lamp to divert current from the lamp when the switching module conducts; and a level control coupled to the switching module, the level control controlling the conductive state of the switching module to vary the current in the lamp according to a dimming control signal supplied to the level control, the level control causing the switching module to switch at a frequency in the range of 300 hertz and higher during times that the lamp current is being varied.

Alley, R.P.

1987-07-21T23:59:59.000Z

8

Energy saving controller for fluorescent lamps.  

E-Print Network (OSTI)

??Although fluorescent lamp is a very efficient lighting device in daily life, still the high harmonic distortion and low power factor cause unnecessary energy consumption.… (more)

Cheong, Zhi Xiong

2010-01-01T23:59:59.000Z

9

Compact Fluorescent Lamps : Technologies : From the Lab to the...  

NLE Websites -- All DOE Office Websites (Extended Search)

process. (Left) Compact Fluorescent Lamp; (Right) Cover of the 'Lighting Retrofit Workbook' (Left) Compact Fluorescent Lamp (CFL) (Right) Retrofitting national parks...

10

Building Technologies Office: Fluorescent and Incandescent Lamps Public  

NLE Websites -- All DOE Office Websites (Extended Search)

Fluorescent and Fluorescent and Incandescent Lamps Public Meeting to someone by E-mail Share Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Facebook Tweet about Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Twitter Bookmark Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Google Bookmark Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Delicious Rank Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on Digg Find More places to share Building Technologies Office: Fluorescent and Incandescent Lamps Public Meeting on AddThis.com... About Standards & Test Procedures Implementation, Certification & Enforcement

11

Long-Term Performance of Screwbase Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

The packaging material for compact fluorescent lamps normally includes some claim regarding expected lamp lifetime. This claimed lifetime is generally not obtained through rigorous testing. This study shows how different operating cycles, components, and lamp and ballast designs affect screwbase compact fluorescent lamp (SCFL) life.

2000-04-11T23:59:59.000Z

12

Energy Performance of Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents the results of tests performed at the Worcester Polytechnic Institute, in contract with the EPRI Power Electronics Applications Center (PEAC), to determine the light output, power consumption, efficiency, and power factor of off-the-shelf electronic and magnetic compact fluorescent lamps.

2003-12-31T23:59:59.000Z

13

Max Tech and Beyond: Fluorescent Lamps  

Science Conference Proceedings (OSTI)

Fluorescent lamps are the most widely used artificial light source today, responsible for approximately 70% of the lumens delivered to our living spaces globally. The technology was originally commercialized in the 1930's, and manufacturers have been steadily improving the efficacy of these lamps over the years through modifications to the phosphors, cathodes, fill-gas, operating frequency, tube diameter and other design attributes. The most efficient commercially available fluorescent lamp is the 25 Watt T5 lamp. This lamp operates at 114-116 lumens per watt while also providing good color rendering and more than 20,000 hours of operating life. Industry experts interviewed indicated that while this lamp is the most efficient in the market today, there is still a further 10 to 14% of potential improvements that may be introduced to the market over the next 2 to 5 years. These improvements include further developments in phosphors, fill-gas, cathode coatings and ultraviolet (UV) reflective glass coatings. The commercialization of these technology improvements will combine to bring about efficacy improvements that will push the technology up to a maximum 125 to 130 lumens per watt. One critical issue raised by researchers that may present a barrier to the realization of these improvements is the fact that technology investment in fluorescent lamps is being reduced in order to prioritize research into light emitting diodes (LEDs) and ceramic metal halide high intensity discharge (HID) lamps. Thus, it is uncertain whether these potential efficacy improvements will be developed, patented and commercialized. The emphasis for premium efficacy will continue to focus on T5 lamps, which are expected to continue to be marketed along with the T8 lamp. Industry experts highlighted the fact that an advantage of the T5 lamp is the fact that it is 40% smaller and yet provides an equivalent lumen output to that of a T8 or T12 lamp. Due to its smaller form factor, the T5 lamp contains less material (i.e., glass, fill gas and phosphor), and has a higher luminance, enabling fixtures to take advantage of the smaller lamp size to improve the optics and provide more efficient overall system illuminance. In addition to offering the market a high-quality efficacious light source, another strong value proposition of fluorescent lighting is its long operating life. In today's market, one manufacturer is offering fluorescent lamps that have a rated life of 79,000 hours - which represents 18 years of service at 12 hours per day, 365 days per year. These lamps, operated using a long-life ballast specified by the manufacturer, take advantage of improvements in cathode coatings, fill gas chemistry and pressure to extend service life by a factor of four over conventional fluorescent lamps. It should be noted that this service life is also longer (approximately twice as long) as today's high-quality LED products. The fluorescent market is currently focused on the T5 and T8 lamp diameters, and it is not expected that other diameters would be introduced. Although T8 is a more optimal diameter from an efficacy perspective, the premium efficiency and optimization effort has been focused on T5 lamps because they are 40% smaller than T8, and are designed to operate at a higher temperature using high-frequency electronic ballasts. The T5 lamp offers savings in terms of materials, packaging and shipping, as well as smaller fixtures with improved optical performance. Manufacturers are actively researching improvements in four critical areas that are expected to yield additional efficacy improvements of approximately 10 to 14 percent over the next five years, ultimately achieving approximately 130 lumens per watt by 2015. The active areas of research where these improvements are anticipated include: (1) Improved phosphors which continue to be developed and patented, enabling higher efficacies as well as better color rendering and lumen maintenance; (2) Enhanced fill gas - adjusting proportions of argon, krypton, neon and xenon to optimize performance, while also m

Scholand, Michael

2012-04-01T23:59:59.000Z

14

Survivability of Electronic Compact Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This EPRI Technical Report addresses the fastest growing energy efficient light source8212the electronic compact fluorescent lamp (CFL). Because some of the failure modes for screw-in CFLs are different than those for plug-in CFLs, a cursory review of the difference between the two types of CFLs is provided in the first part of Chapter 2. A broad definition of shortened-life CFLs is also provided in Chapter 2 with an emphasis on revisiting mortality curves, the 10-minute lamp start, other relevant defini...

2008-03-31T23:59:59.000Z

15

Novel Nanophosphors for High Efficiency Fluorescent Lamps  

SciTech Connect

This is the Final Report of the Novel Nanophosphors for High Efficiency Fluorescent Lamps, Department of Energy (DOE). The overall goal of this three-year program is to develop novel hybrid phosphors by coating commercially available lamp phosphors with highly stable wide band-gap nanocrystalline phosphors (NCP). The prime technical approach is the development of NCP quantum-splitting phosphor (QSP) and ultra-violet (UV) emitting phosphors with quantum efficiencies exceeding that of the conventional phosphors at 185 nm. The novel hybrid phosphors will increase the efficiency of the fluorescent lamps by up to 32%, enabling total energy savings of 0.26 quads, the reduction in the U.S. energy bill by $6.5 billion and the reduction of the annual carbon emission by 4.1 billion kilogram. Our work started by investigating through modeling calculations the requirement for the particle size of the NCP. Our work to develop suitable nanocrystalline phosphors started with the known oxide quantum splitting and UV emitting phosphors. We demonstrated several synthesis techniques for the production of high quality nanocrystalline materials that crystallizes in the desired phase and with the desired particle size. In collaboration with our subcontractor we demonstrated the feasibility for the manufacture of NC phosphors. We also demonstrated novel techniques of coating the NCP on the surface of micron sized phosphors. Our chief achievement pertains to the successful testing of the coated hybrid phosphor systems in linear fluorescent lamps. In linear fluorescent lamp tests, we have demonstrated up to 7% increase in the efficacy of hybrid phosphors over the conventional (uncoated) phosphors. We have also demonstrated the improvement in the lumen maintenance of the coated phosphors. A hybrid phosphor system based on the commercial red emitting phosphor, Y{sub 2}O{sub 3}:Eu{sup 3+} did not show the anticipated improvement in lamp efficacy. We explored the reasons for this observation, which are detailed in this report. Within the program we have carried out fundamental investigations into the physical processes that determine the quantum splitting behavior of the Pr{sup 3+} ion in solids. Specifically, we have investigated the quantum splitting luminescence of this ion in the LaPO{sub 4}, SrAl{sub 12}O{sub 19} and LiLaP{sub 4}O{sub 12} host lattices. In this final report we summarize the technical work completed under the Program, summarize our findings about the performance limits of the various technologies we investigated, and outline promising paths for future work.

Alok Srivatava

2007-03-31T23:59:59.000Z

16

Energy Cost Calculator for Compact Fluorescent Lamps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Compact Fluorescent Lamps Compact Fluorescent Lamps Energy Cost Calculator for Compact Fluorescent Lamps October 8, 2013 - 2:18pm Addthis This tool calculates the payback period for your calc retrofit project. Modify the default values to suit your project requirements. Existing incandescent lamp wattage Watts Incandescent lamp cost dollars Incandescent lamp life 1000 hours calc wattage Watts calc cost dollars calc life (6000 hours for moderate use, 10000 hours for high use) 8000 hours Number of lamps in retrofit project Hours operating per week hours Average cost of electricity 0.06 $/kWh Relamper labor costs $/hr Time taken to retrofit all lamps in this project min Time taken to relamp one lamp min Type of Relamping Practiced: Group Relamping: Calculate Simple Payback Period months

17

The Effects of Table Lamp Shade Shape and Compact Fluorescent...  

NLE Websites -- All DOE Office Websites (Extended Search)

The Effects of Table Lamp Shade Shape and Compact Fluorescent Lamp Burning Position on Visual Comfort Speaker(s): Zaidi Abdullah Date: March 15, 2001 - 12:00pm Location: Bldg. 90...

18

Light Flicker in Compact Fluorescent Lamps Caused by Voltage Fluctuations  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents tests performed at the EPRI Power Electronics Applications Center (PEAC) Power Quality Test Facility to characterize the light output of an incandescent lamp and compact fluorescent lamps during voltage fluctuations.

2003-12-31T23:59:59.000Z

19

Fluorescent lamp unit with magnetic field generating means  

DOE Patents (OSTI)

A fluorescent lamp unit having a magnetic field generating means for improving the performance of the fluorescent lamp is disclosed. In a preferred embodiment the fluorescent lamp comprises four longitudinally extending leg portions disposed in substantially quadrangular columnar array and joined by three generally U-shaped portions disposed in different planes. In another embodiment of the invention the magnetic field generating means comprises a plurality of permanent magnets secured together to form a single columnar structure disposed within a centrally located region defined by the shape of lamp envelope. 4 figs.

Grossman, M.W.; George, W.A.

1989-08-08T23:59:59.000Z

20

Compatibility testing of fluorescent lamp and ballast systems  

SciTech Connect

The rapid growth in the use of electronic ballasts for fluorescent lighting systems, and the corresponding increase in the number of new products and new manufacturers in the market, has raised a number of questions regarding the compatibility of the lamps and ballasts used in fluorescent systems. Because many of the new products start and operate lamps differently than previous products, the relevant American National Standards Institute requirements may no longer be adequate for addressing compatibility concerns. The impacts on system performance of the newer products of a parametric study designed to test key hypotheses regarding the impact of ballast parameters on fluorescent lamp life. In this study, samples of 4-ft T8 fluorescent lamps were operated on duty cycles of 5 min on and 5 min off, using seven different ballast types. The results of the study indicate which parameters seem to have the biggest effect on lamp life, and can be used in establishing new performance standards for fluorescent systems.

Ji, Y.; Davis, R.; O' Rourke, C.; Chui, E.W.M.

1999-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Heat transfer assembly for a fluorescent lamp and fixture  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure. 11 figs.

Siminovitch, M.J.; Rubenstein, F.M.; Whitman, R.E.

1992-12-29T23:59:59.000Z

22

Heat transfer assembly for a fluorescent lamp and fixture  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, a heat transfer structure is disclosed for reducing the minimum lamp wall temperature of a fluorescent light bulb. The heat transfer structure, constructed of thermally conductive material, extends from inside the housing to outside the housing, transferring heat energy generated from a fluorescent light bulb to outside the housing where the heat energy is dissipated to the ambient air outside the housing. Also disclosed is a method for reducing minimum lamp wall temperatures. Further disclosed is an improved lighting fixture including a lamp, a housing and the aforementioned heat transfer structure.

Siminovitch, Michael J. (Richmond, CA); Rubenstein, Francis M. (Berkeley, CA); Whitman, Richard E. (Richmond, CA)

1992-01-01T23:59:59.000Z

23

Fluorescent lamp with static magnetic field generating means  

DOE Patents (OSTI)

A fluorescent lamp wherein magnetic field generating means (e.g., permanent magnets) are utilized to generate a static magnetic field across the respective electrode structures of the lamp such that maximum field strength is located at the electrode's filament. An increase in efficacy during operation has been observed.

Moskowitz, Philip E. (Peabody, MA); Maya, Jakob (Brookline, MA)

1987-01-01T23:59:59.000Z

24

Fluorescent lamp with static magnetic field generating means  

DOE Patents (OSTI)

A fluorescent lamp wherein magnetic field generating means (e.g., permanent magnets) are utilized to generate a static magnetic field across the respective electrode structures of the lamp such that maximum field strength is located at the electrode's filament. An increase in efficacy during operation has been observed. 2 figs.

Moskowitz, P.E.; Maya, J.

1987-09-08T23:59:59.000Z

25

Convection venting lensed reflector-type compact fluorescent lamp system  

DOE Patents (OSTI)

Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures. 12 figs.

Pelton, B.A.; Siminovitch, M.

1997-07-29T23:59:59.000Z

26

Convection venting lensed reflector-type compact fluorescent lamp system  

SciTech Connect

Disclosed herein is a fluorescent lamp housing assembly capable of providing convection cooling to the lamp and the ballast. The lens of the present invention includes two distinct portions, a central portion and an apertured portion. The housing assembly further includes apertures so that air mass is able to freely move up through the assembly and out ventilation apertures.

Pelton, Bruce A. (825 Manor Rd., El Sobrante, CA 94803); Siminovitch, Michael (829 Manor Rd., El Sobrante, CA 94803)

1997-01-01T23:59:59.000Z

27

Covered Product Category: Compact Fluorescent Lamps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Covered Product Category: Compact Fluorescent Lamps Covered Product Category: Compact Fluorescent Lamps Covered Product Category: Compact Fluorescent Lamps October 7, 2013 - 10:48am Addthis ENERGY STAR Qualified Products Federal Energy Management Program (FEMP) provides acquisition guidance across a variety of product categories, including compact fluorescent lamps (CFLs), which are an ENERGY STAR-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR.

28

Information Resources: LED Replacements for Linear Fluorescent Lamps  

NLE Websites -- All DOE Office Websites (Extended Search)

Replacements for Linear Fluorescent Lamps Webcast Replacements for Linear Fluorescent Lamps Webcast In this June 20, 2011 webcast on LED products marketed as replacements for linear fluorescent lamps, Jason Tuenge of the Pacific Northwest National Laboratory (PNNL) discussed current Lighting Facts-listed products as well as products evaluated in the latest CALiPER reports. Eric Richman, also of PNNL, reported on a recently completed GATEWAY demonstration project, in which LED and fluorescent lamps were installed in a variety of recessed troffer luminaires for comparison in an office environment. The presentation concluded with a discussion of specifications listed in a newly updated technology fact sheet. View presentation slides View the text-alternative version View the webcast (WMV 16 MB) Download Windows Media Player

29

Effect of filament power removal on a fluorescent lamp system  

SciTech Connect

Two techniques are used to measure the effects of removing the filament power from a two-lamp, F-40, rapid-start fluorescent lamp system. The changes are measured for a standard CBM core-coil ballast and for a solid-state ballast operating the lamp at high frequency. There is a 4 tp 6% increase in system efficacy when the filament power is removed. Removal of filament power also decreases filament temperature from 1000/sup 0/C to below 700/sup 0/C in lamps operated at 60 Hz, and from above 600/sup 0/C to 300/sup 0/C in lamps operated at high frequency. The study shows that the arc current and anode fall also determine filament temperature.

Verderber, R.R.; Morse, O.; Rubinstein, F.M.

1985-07-01T23:59:59.000Z

30

Electronic Radio-Frequency (Electrodeless) Induction Lamps: A Fluorescent Technology  

Science Conference Proceedings (OSTI)

This EPRI Technical Update addresses an expanding energy efficient light source electronic radio-frequency (electrodeless) induction lamps. Business and technical market factors (Chapter 2) use the past and future growth of the CFL market to illustrate the potential for the induction lighting market while emphasizing future technical improvements. Discussion of the importance of utility involvement in helping their customers consider induction lamps for high-efficiency fluorescent applications with long-...

2007-12-20T23:59:59.000Z

31

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium vapor lamps, ultraviolet and  

E-Print Network (OSTI)

Mercury Lamps Recycling Fluorescent light-tubes, compact fluorescent bulbs, mercury and sodium light tubes are recycled. They are made from aluminum and metal. Aluminum is a silver-white metal and is very light in weight and strong. Because aluminum is ductile, it can be drawn into wires or pressed

Ungerleider, Leslie G.

32

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry  

NLE Websites -- All DOE Office Websites (Extended Search)

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry Speaker(s): Francis Rubinstein Date: February 14, 2008 - 12:00pm Location: 90-3122 Fluorescent lamp ballasts are subject to DOE appliance standards and rulemaking. But currently, only ballasts for older fluorescent lamp types, such as T-12 lamps are subject to minimum efficacy limits. The majority of fluorescent lamps now being shipped (T-8 and T-5 types) type are operated by ballasts that will not be subject to DOE rule until 2011. The metric used by DOE for characterizing the electrical efficiency of the fluorescent lamp-ballast system is called Ballast Efficacy Factor (BEF). Because BEF is not normalized, it is of limited utility for rulemaking and is useless for procurement. But by normalizing BEF to the total lamp power, I have

33

Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry  

DOE Patents (OSTI)

A novel design is described for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment. 9 figs.

Siminovitch, M.

1998-02-10T23:59:59.000Z

34

Compact fluorescent lamp using horizontal and vertical insulating septums and convective venting geometry  

SciTech Connect

A novel design for a compact fluorescent lamp, including a lamp geometry which will increase light output and efficacy of the lamp in a base down operating position by providing horizontal and vertical insulating septums positioned in the ballast compartment of the lamp to provide a cooler coldspot. Selective convective venting provides additional cooling of the ballast compartment.

Siminovitch, Michael (El Sobrante, CA)

1998-01-01T23:59:59.000Z

35

Information on the Fate of Mercury From Fluorescent Lamps Disposed in Landfills  

Science Conference Proceedings (OSTI)

Mercury is contained in energy-efficient fluorescent, mercury-vapor, metal halide, and high-pressure sodium lamps. This report presents information on the potential for air and groundwater contamination when mercury lamps are disposed in municipal landfills.

1995-04-19T23:59:59.000Z

36

Dimming of Compact Fluorescent Lamps Caused By Cold-Air Drafts  

Science Conference Proceedings (OSTI)

This Case Study documents the investigation performed by the New York Port Authority (PA) of the dimming of compact fluorescent lamps (CFLs) in the World Trade Center.

2003-12-31T23:59:59.000Z

37

Power control architectures for cold cathode fluorescent lamp and light emitting diode based light sources.  

E-Print Network (OSTI)

?? In this dissertation, two different energy efficient power supply topologies are introduced for controlling cold cathode fluorescent lamp (CCFL) and high-brightness light emitting diode… (more)

Doshi, Montu V.

2010-01-01T23:59:59.000Z

38

Conservation potential of compact fluorescent lamps in India and Brazil  

SciTech Connect

We evaluate the conservation potential of compact fluorescent lamps (CFLs) for managing the rapidly increasing electrical energy and peak demand in India and Brazil. Using very conservative assumptions, we find that the cost of conserved energy using 16 W CFLs is 4 and 6 times less than the long range marginal cost of electricity for the two countries. The cost of avoided peak installed capacity is 6 and 9.5 times less than the cost of new installed capacity for India and Brazil. The analysis is undertaken from the three separate perspectives of the national economies, the consumers, and the utilities. We find that because residential electricity is subsidized, the consumers have little or no incentive to purchase and install the CFLs, unless they too are subsidized. However, the benefits of CFL installation to the utility are so large that subsidizing them is a paying proposition for the utility are so large that subsidizing them is a paying proposition for the utility in almost all cases. As an illustration of a gradual introduction strategy for CFLs, we calculate a scenario where national savings of the order of US $1.2 million per day for India and US $2.5 million per day for Brazil are reached in 10 years by a small and gradual transfer of subsidy from residential electricity to CFLs. We then explore the barriers to immediate large scale introduction of these lamps in the two countries. Specific technical and marketing problems are identified and discussed, which would require solution before such an introduction can be attempted. Lastly, we discuss the range of policy instruments, in addition to a subsidy scheme, that can be used for promoting the diffusion of these lamps in the domestic and commercial sector. 47 refs., 15 figs., 2 tabs.

Gadgil, A.; Martino Jannuzzi, G. de (Lawrence Berkeley Lab., CA (USA); Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia)

1989-07-01T23:59:59.000Z

39

The effects of supply harmonics on the performance of compact fluorescent lamps  

SciTech Connect

This paper describes a performance evaluation of ten compact fluorescent lighting systems operated with sinusoidal and distorted voltage waveform conditions. The lamps were either provided with an electronic ballast, a magnetic core ballast or a magnetic core ballast with a power factor correction circuit. The test results show that the electrical performance of the compact fluorescent lamps for both sinusoidal and distorted voltage waveform operation is related to the different types of ballast used. The cost of operation of these compact fluorescent lamps was calculated and compared to the cost of a conventional 60 W incandescent lamp.

Arseneau, R.; Ouellette, M.

1993-04-01T23:59:59.000Z

40

Energy-efficient compact screw-in fluorescent lamp. Final report  

SciTech Connect

A compact fluorescent lamp has been designed and constructed which can replace an incandescent lamp. The lamp is slightly larger than a standard lamp (8 3/4 in. x 3 1/4 in.), but is designed to fit a majority of portable lamp applications. This version, with a core-coil ballast, results in a system efficacy of 54 lumens per watt, with a light output of more than 1800 lumens. This compares favorably with a 100-watt incandescent (17.5 lumens per watt and 1750 lumens light output). The color temperature of 3000/sup 0/K is compatible with an incandescent lamp (2800/sup 0/K). The color rendition index (CRI) is 84. With a solid-state ballast, the efficacy and light output could be increased by 20% (65 l/w, 2200 lumens) and could provide a direct replacement for a three-way, 150-watt incandescent lamp (15 l/w, 2200 lumens).

Morton, E.W.

1982-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Performance of electronic ballasts and lighting controllers with 34-W fluorescent lamps: Final report  

SciTech Connect

This study has measured the performance of energy-saving 34-watt F40, T-12, rapid-start, lite white fluorescent lamps being operated by solid-state ballasts and lighting control equipment. The performances of these lamps are compared with those of 40-watt F40, T-12 rapid-start cool white fluorescent lamp systems studied in the prior phase of this project. With the 34-watt F40 lamps and various solid-state ballasts, system efficacy ranged from 67 to 84 lumens per watt and ballast factor from 0.756 to 0.908. Average system efficacy using the 34-watt lamps exceeded that of systems using 40-watt lamps and the same solid-state ballasts by only 1 percent even though the 34-watt lamps is about 6 percent more efficacious than the 40-watt lamp. This apparent discrepancy is due to increased ballast losses when operating the 34-watt lamps. However, the system efficacy of the 34-watt lamps used with a solid-state ballast exceeded that of a 34-watt, two-lamp system using the standard core-coil ballast by as much as 29 percent. A T-8 fluorescent lamp system with a smaller lamp diameter was also included in the study. Operating this lamp with a solid-state ballast produced a high system efficacy of 90 lumens per watt, a 39 percent improvement over the efficacy of a 40-watt F40 system using the standard core-coil ballast. The use of static controllers with 34-watt F40 lamps can result in excessive flickering (46 percent) and the generation of a second harmonic as high as 96 percent of the fundamental frequency. The dynamic controllers, when used to dim the 34-watt lamps generally cannot be dimmed as low as the 40-watt lamp system without flickering. In general, the 34-watt energy-saving lamps are appropriate as a retrofit to reduce illumination levels. However, for new construction, the 40-watt F40 argon filled lamps cost less, perform better, and provide a more reliable system. 5 refs., 27 figs., 9 tabs.

Verderber, R.R.

1988-06-01T23:59:59.000Z

42

Performance of T12 and T8 Fluorescent Lamps and Troffers and LED Linear Replacement Lamps CALiPER Benchmark Report  

Science Conference Proceedings (OSTI)

The Department of Energy (DOE) Commercially Available LED Product Evaluation and Reporting (CALiPER) Program was established in 2006 to investigate the performance of light-emitting diode (LED) based luminaires and replacement lamps. To help users better compare LED products with conventional lighting technologies, CALiPER has also performed benchmark research and testing of traditional (i.e., non-LED) lamps and fixtures. This benchmark report addresses standard 4-foot fluorescent lamps (i.e., T12 and T8) and the 2-foot by 4-foot recessed troffers in which they are commonly used. This report also examines available LED replacements for T12 and T8 fluorescent lamps, and their application in fluorescent troffers. The construction and operation of linear fluorescent lamps and troffers are discussed, as well as fluorescent lamp and fixture performance, based on manufacturer data and CALiPER benchmark testing. In addition, the report describes LED replacements for linear fluorescent lamps, and compares their bare lamp and in situ performance with fluorescent benchmarks on a range of standard lighting measures, including power usage, light output and distribution, efficacy, correlated color temperature, and the color rendering index. Potential performance and application issues indicated by CALiPER testing results are also examined.

Myer, Michael; Paget, Maria L.; Lingard, Robert D.

2009-01-16T23:59:59.000Z

43

A new optimized fluorescent lamp and ballast for low-energy general lighting applications  

SciTech Connect

A new fluorescent lamp and ballast system has been developed which minimizes system input power while maintaining light output close to values provided by conventional lamps and ballasts. The 28-WT-12 lamp designed for the new system utilizes a redesigned electrode structure which allows the lamp to be started in the rapid start manner but operated in an instant start mode to maximize the discharge efficacy (lumens/watt) while reducing lamp cathode power requirements. A matching two-lamp ballast incorporates a solid-state switching device to turn off the cathode heating circuit automatically once the lamps have started. Both lamps and ballasts are physically interchangeable with conventional equipment so that existing luminaires can be converted without luminaire, lampholder, and wiring modifications. This new lamp/ballast system can achieve efficacy values exceeding 80 lm/W--more than 25 percent better than the performance of conventional fluorescent systems of the early 1970's-along with the excellent life and reliability characteristics typical of electromagnetically ballasted systems. Economic analyses indicate that the new system is appropriate for many new commercial general lighting installations, although it is particularly suitable as a retrofit system for installations where power reductions are essential but where conversion costs must be minimized and illumination levels preserved.

Hammer, E.E.; McGowan, T.K.

1983-07-01T23:59:59.000Z

44

Selecting effective fluorescent lamp and ballast for retrofit in the continental United States. Final report  

SciTech Connect

Electrical lighting is a major contributor to daytime peak energy demand, accounting for about 30 percent of total electricity consumption in most Army facilities. Some of this energy may be wasted because many existing lighting systems at Army Installations use outmoded technologies. While recent technology has improved the energy efficiency of all lighting systems, fluorescent lighting-the most widely used interior building lighting-has shown the greatest efficiency gains. Retrofits using high-efficiency fluorescent lamps and ballasts can yield significant operating cost savings. High-efficiency fluorescent lighting systems are widely available, but current information on their performance characteristics is highly technical and not easily accessible to Army facility managers considering retrofit options. This report provides a single, accessible source that summarizes fluorescent lamp and ballast performance characteristics and outlines selection procedures. Fluorescent lamp, Retrofit, Ballast, Lighting. Energy conservation.

Taylor, W.R.

1993-08-01T23:59:59.000Z

45

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

SciTech Connect

Lighting has been one of the fastest growing electric end-uses in China over the last twenty years, with an average annual growth rate of 14%. Fluorescent lighting provides a significant portion of China's lighting need. In 1998, China produced 680 million fluorescent lamps, of which 420 million were linear fluorescent lamps of various diameters (T8 to T12). There are substantial variations both in energy efficiency and lighting performance among locally produced fluorescent lamps. Such variations present a perfect opportunity for policy intervention through efficiency standards to promote the adoption of more efficient fluorescent lamps in China. This paper analyzes China's proposed minimum efficiency standard for fluorescent lamps and presents an assessment of its likely impacts on China's lighting energy consumption and GHG emissions.

Lin, Jiang

2002-04-11T23:59:59.000Z

46

Integrated starting and running amalgam assembly for an electrodeless fluorescent lamp  

DOE Patents (OSTI)

An integrated starting and running amalgam assembly for an electrodeless SEF fluorescent lamp includes a wire mesh amalgam support constructed to jointly optimize positions of a starting amalgam and a running amalgam in the lamp, thereby optimizing mercury vapor pressure in the lamp during both starting and steady-state operation in order to rapidly achieve and maintain high light output. The wire mesh amalgam support is constructed to support the starting amalgam toward one end thereof and the running amalgam toward the other end thereof, and the wire mesh is rolled for friction-fitting within the exhaust tube of the lamp. The positions of the starting and running amalgams on the wire mesh are jointly optimized such that high light output is achieved quickly and maintained, while avoiding any significant reduction in light output between starting and running operation.

Borowiec, Joseph Christopher (Schenectady, NY); Cocoma, John Paul (Clifton Park, NY); Roberts, Victor David (Burnt Hills, NY)

1998-01-01T23:59:59.000Z

47

X-ray Methods in High-Intensity Discharges and Metal-Halide Lamps: X-ray Induced Fluorescence  

SciTech Connect

We describe the use of x-ray induced fluorescence to study metal-halide high-intensity discharge lamps and to measure equilibrium vapor pressures of metal-halide salts. The physical principles of metal-halide lamps, relevant aspects of x-ray-atom interactions, the experimental method using synchrotron radiation, and x-ray induced fluorescence measurements relevant to metal-halide lamps are covered.

Curry, John J.; Lapatovich, Walter P.; Henins, Albert (NIST)

2011-12-09T23:59:59.000Z

48

Potential Environmental Impacts from the Metals in Incandescent, Compact Fluorescent Lamp (CFL), and Light-Emitting Diode (LED)  

E-Print Network (OSTI)

), and Light-Emitting Diode (LED) Bulbs Seong-Rin Lim, Daniel Kang, Oladele A. Ogunseitan,,§ and Julie M sources with compact fluorescent lamp (CFL) and light-emitting diode (LED) bulbs that use about 70% and 85 lighting systems are transitioning from incandes- cent to compact fluorescent lamp (CFL) and light

Short, Daniel

49

Energy Performance and Emissions of Electronic Ballasts Powering 4-Foot Fluorescent Lamps  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents tests performed at the Worcester Polytechnic Institute, in contract with the EPRI Power Electronics Applications Center (PEAC) to determine the average efficacy (lumens per watt), displacement power factor, total power factor, and current harmonic distortion of modern electronic ballasts powering fluorescent lamps.

2003-12-31T23:59:59.000Z

50

A Comparative Verification of Localized Aviation Model Output Statistics Program (LAMP) and Numerical Weather Prediction (NWP) Model Forecasts of Ceiling Height and Visibility  

Science Conference Proceedings (OSTI)

In an effort to support aviation forecasting, the National Weather Service’s Meteorological Development Laboratory (MDL) has recently redeveloped the Localized Aviation Model Output Statistics (MOS) Program (LAMP) system. LAMP is designed to run ...

David E. Rudack; Judy E. Ghirardelli

2010-08-01T23:59:59.000Z

51

Treatability study for removal of leachable mercury in crushed fluorescent lamps  

SciTech Connect

Nonserviceable fluorescent lamps removed from radiological control areas at the Oak Ridge Department of Energy facilities have been crushed and are currently managed as mixed waste (hazardous and radiologically contaminated). We present proposed treatment flowsheets and supporting treatability study data for conditioning this solid waste residue so that it can qualify for disposal in a sanitary landfill. Mercury in spent fluorescent lamps occurs primarily as condensate on high-surface-area phosphor material. It can be solubilized with excess oxidants (e.g., hypochlorite solution) and stabilized by complexation with halide ions. Soluble mercury in dechlorinated saline solution is effectively removed by cementation with zero-valent iron in the form of steel wool. In packed column dynamic flow testing, soluble mercury was reduced to mercury metal and insoluble calomel, loading > 1.2 g of mercury per grain of steel wool before an appreciable breakthrough of soluble mercury in the effluent.

Bostick, W.D.; Beck, D.E.; Bowser, K.T. [and others

1996-02-01T23:59:59.000Z

52

Determination of mercury distribution inside spent compact fluorescent lamps by atomic absorption spectrometry  

Science Conference Proceedings (OSTI)

Highlights: Black-Right-Pointing-Pointer New treatments for CFL are required considering the aim of Directive 202/96/CE. Black-Right-Pointing-Pointer It is shown that most of the mercury introduced into a CFL is in the phosphor powder. Black-Right-Pointing-Pointer Experimental conditions for microwave-assisted sample digestion followed by AAS measurements are described. Black-Right-Pointing-Pointer By washing the glass it is possible to reduce the concentration below legal limits. - Abstract: In this study, spent compact fluorescent lamps were characterized to determine the distribution of mercury. The procedure used in this research allowed mercury to be extracted in the vapor phase, from the phosphor powder, and the glass matrix. Mercury concentration in the three phases was determined by the method known as cold vapor atomic absorption spectrometry. Median values obtained in the study showed that a compact fluorescent lamp contained 24.52 {+-} 0.4 ppb of mercury in the vapor phase, 204.16 {+-} 8.9 ppb of mercury in the phosphor powder, and 18.74 {+-} 0.5 ppb of mercury in the glass matrix. There are differences in mercury concentration between the lamps since the year of manufacture or the hours of operation affect both mercury content and its distribution. The 85.76% of the mercury introduced into a compact fluorescent lamp becomes a component of the phosphor powder, while more than 13.66% is diffused through the glass matrix. By washing and eliminating all phosphor powder attached to the glass surface it is possible to classified the glass as a non-hazardous waste.

Rey-Raap, Natalia [Departamento de Ingenieria Mecanica y Construccion, Universitat Jaume I de Castellon, Av. de Vicent Sos Baynat s/n, 12071 Castellon de la Plana, Espana (Spain); Gallardo, Antonio, E-mail: gallardo@emc.uji.es [Departamento de Ingenieria Mecanica y Construccion, Universitat Jaume I de Castellon, Av. de Vicent Sos Baynat s/n, 12071 Castellon de la Plana, Espana (Spain)

2012-05-15T23:59:59.000Z

53

NIST energy related inventions: Electronic starter device for fluorescent lamps. Interim report, August--October, 1997  

SciTech Connect

From the Scope of Work document which accompanied the original proposal, three silicon devices were anticipated for development, simulation, and quality assurance fabrication. The status of these are in the same format as the Scope of Work...Attachment-A-: Task 1--design and simulation; Task 2--prototype tooling; Task 3--test engineering; Task 4--product tooling; Task 5--package tooling/manufacturing design and assembly. It is felt the program will meet it`s stated goals of producing a low cost, high performance fluorescent lamp starter which will lower the acquisition and operating cost of fluorescent technology...thus saving significant amounts of energy. The likelihood of success is even greater, now that the TN22 component has been qualified. The challenges of creating a custom ASIC, while still significant, are within the skill and expertise level or the assigned engineers.

Johnson, S.A.

1997-12-01T23:59:59.000Z

54

The effects of fixture type and HVAC integration on fluorescent lamp/ballast performance  

SciTech Connect

This paper describes the effects of fixture type and lamp compartment air extract characteristics on lamp/ballast performance. A luminaire/plenum/HVAC simulator was used to measure minimum lamp wall temperature inside four fixture types while varying lamp-compartment extract conditions. Experimental data show that the lumen output of the lamp/ballast system varies by 20% and system efficacy by 10%, depending on the type of fixture and lamp-compartment extract technique employed.

Siminovitch, M.J.; Rubinstein, F.M.; Verderber, R.R.; Clark, T.A.

1986-06-01T23:59:59.000Z

55

Mercury reduction studies to facilitate the thermal decontamination of phosphor powder residues from spent fluorescent lamps  

SciTech Connect

This work investigates the thermal release of mercury from phosphor powder of spent fluorescent lamps. The treatment conditions and the ability of various reducing agents (primarily sodium borohydride) to lower the overall heating temperature required to improve the release of Hg have been evaluated. Hg species in samples were monitored in a thermal desorption atomic absorption spectrometer system, and total mercury was analyzed in a cold vapor atomic absorption spectrometer. Sodium borohydride was the best reducing agent among the ones studied. However, citric acid presented a high capacity to weaken mercury bonds with the matrix. When the sample was crushed with sodium borohydride for 40 min in a mass ratio of 10:1 (sample:reducing agent) and submitted to thermal treatment at 300 deg. C for 2 h, the concentration of mercury in a phosphor powder sample with 103 mg kg{sup -1} of mercury reached 6.6 mg kg{sup -1}.

Alves Durao, Walter [Chemistry Department, Federal University of Minas Gerais (UFMG), Cidade Universitaria 30.123-970 Belo Horizonte, MG (Brazil); Andreva de Castro, Camila [Chemistry Engineering Department, Federal University of Minas Gerais (UFMG) (Brazil); Carvalhinho Windmoeller, Claudia [Chemistry Department, Federal University of Minas Gerais (UFMG), Cidade Universitaria 30.123-970 Belo Horizonte, MG (Brazil)], E-mail: claucw@netuno.lcc.ufmg.br

2008-11-15T23:59:59.000Z

56

Side-by-Side Testing of Commercial Office Lighting Systems: Two-lamp Fluorescent Fixtures  

E-Print Network (OSTI)

Lighting systems in commercial office buildings are primary determinants of building energy use. In warmer climates, lighting energy use has important implications for building cooling loads as well as those directly associated with illumination tasks. To research the comparative performance of conventional and advanced office lighting systems, Florida Solar Energy Center (FSEC) set up the Lighting Flexible Test Facility (LFTF) which allows side-by-side comparison of lighting options in two otherwise identical 2.7 m x 3.7 m (9' x 12') south facing offices. The ceiling of the LFTF contains 0.61 m x 1.2 m (2' x 4') recessed fluorescent fixtures designed to be easily changed. Differing lighting systems were comparatively tested against each other over weeklong periods. Data on power consumption (watts), power quality (power factor), work-plane interior lighting levels (lux), bulb-wall, fixture and plenum temperatures were recorded every 15 minutes on a multi-channel data logger. This data allows realistic analysis of comparative lighting system performance including interactions with daylighting.

Parker, D. S.; Schrum, L.; Sonne, J. K.; Stedman, T. C.

1996-01-01T23:59:59.000Z

57

Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface.

Siminovitch, Michael J. (Richmond, CA)

1992-01-01T23:59:59.000Z

58

Thermal element for maintaining minimum lamp wall temperature in fluorescent fixtures  

DOE Patents (OSTI)

In a lighting fixture including a lamp and a housing, an improvement is disclosed for maintaining a lamp envelope area at a cooler, reduced temperature relative to the enclosed housing ambient. The improvement comprises a thermal element in thermal communication with the housing extending to and springably urging thermal communication with a predetermined area of the lamp envelope surface. 12 figs.

Siminovitch, M.J.

1992-11-10T23:59:59.000Z

59

Performance of electronic ballasts and other new lighting equipment: (Phase 2, The 34-watt F40 rapid start T-12 fluorescent lamp): Final report  

SciTech Connect

This study has measured the performance of energy-saving 34-watt F40, T-12, rapid-start, lite white fluorescent lamps being operated by solid-state ballasts and lighting control equipment. The performances of these lamp systems are compared with those of 40-watt F40, T-12 rapid-start cool white fluorescent lamp systems studied in the prior phase of this project. With the 34-watt F40 lamps and various solid-state ballasts, system efficacy ranged from 67 to 84 lumens per watt and ballast factor from 0.756 to 0.908. Average system efficacy using the 34-watt lamps exceeded that of systems using 40-watt lamps and the same solid-state ballasts by only 1 percent even though the 34-watt lamps is about 6 percent more efficacious than the 40-watt lamp. This apparent discrepancy is due to increased ballast losses when operating the 34-watt lamps. However, the systems efficacy of the 34-watt lamps used with a solid-state ballast exceeded that of a 34-watt, two-lamp system using the standard core-coil ballast by as much as 29 percent. A T-8 fluorescent lamp system with a smaller lamp diameter was also included in the study. Operating this lamp with a solid-state ballast produced a high system efficacy of 90 lumens per watt, a 39 percent improvement over the efficacy of a 40-watt F40 system using the standard core-coil ballast. The use of static controllers with 34-watt F40 lamps can result in excessive flickering (46 percent) and the generation of a second harmonic as high as 96 percent of the fundamental frequency. The dynamic controllers, when used to dim the 34-watt lamps generally cannot be dimmed as low as the 40-watt lamp system without flickering. In general, the 34-watt energy-saving lamps are appropriate as a retrofit to reduce illumination levels. However, for new construction, the 40-watt F40 argon filled lamps cost less, perform better, and provide a more reliable system. 5 refs., 27 figs., 9 tabs.

Verderber, R.R.; Morse, O.

1988-02-01T23:59:59.000Z

60

Ceiling Fan | Open Energy Information  

Open Energy Info (EERE)

Ceiling Fan Jump to: navigation, search TODO: Add description List of Ceiling Fan Incentives Retrieved from "http:en.openei.orgwindex.php?titleCeilingFan&oldid267151"...

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Process for environmentally safe disposal of used fluorescent lamp potted ballast assemblies with component part reclamation and/or recycling  

SciTech Connect

A process is described for the environmentally safe and economical disposal of used fluorescent lamp potted ballast housing assemblies comprising removing from the housing the potted assembly with its embedded electrical component assemblies including a component capacitor containing environmentally hazardous material PCB's; after or before such removing, immersing the potted assembly in a cryogenic bath and freezing the same to reader the potting sufficiently brittle to fragment into small pieces upon being impacted; impacting the potting thoroughly to crush and fragment the same into small pieces and to cleanly remove substantially all traces of the potting from all the electrical components and parts embedded therein and without imparting damage to the components and parts; disconnecting the component containing the environmentally hazardous material; and incinerating only the component containing the environmentally hazardous material, leaving all other components and parts including the housing and potting fragments for salvage, re-use and/or recycling.

Nardella, A.; Norian, B.

1993-07-27T23:59:59.000Z

62

Record of Communication Concerning Ceiling Fan and Ceiling Fan...  

NLE Websites -- All DOE Office Websites (Extended Search)

Record of Communication Concerning Ceiling Fan and Ceiling Fan Light Kit Framework Document-Docket No. EERE-2012-BT-STD-0045 Record of Communication Concerning Ceiling Fan and...

63

DOE/EA-1664: Environmental Assessment for 10 CFR 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps (June 2009)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4 4 Environmental Assessment for 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps June 2009 16-i CHAPTER 16. ENVIRONMENTAL ASSESSMENT TABLE OF CONTENTS 16.1 INTRODUCTION ......................................................................................................... 16-1 16.2 AIR EMISSIONS ANALYSIS...................................................................................... 16-1 16.2.1 Air Emissions Descriptions............................................................................................ 16-1 16.2.2 Air Quality Regulation................................................................................................... 16-3 16.2.3 Global Climate Change..................................................................................................

64

Assessment of Electrical, Efficiency, and Photometric Performance of Advanced Lighting Sources: Dimmable Advanced Lighting Technolog ies -- Electronic (Hot and Cold Cathode) Compact Fluorescent Lamps and Ballasts  

Science Conference Proceedings (OSTI)

This EPRI Technical Update (EPRI report 1018477) is one of four in a series that addresses basic dimming performance of advanced lighting sourceselectronic (hot and cold cathode) compact fluorescent lamps and ballasts Chapter 1 discusses basic lighting control, the importance of considering power quality in lighting control, lighting control methods and parameters, and the advantages and future of lighting control. Chapter 2 addresses in more depth dimming methods used in advanced lighting sources and co...

2008-12-19T23:59:59.000Z

65

Energy Basics: Fluorescent Lighting  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

& Cooling Water Heating Fluorescent Lighting Fluorescent lamps use 25%-35% of the energy used by incandescent lamps to provide the same amount of illumination (efficacy of...

66

Max Tech and Beyond: High-Intensity Discharge Lamps  

Science Conference Proceedings (OSTI)

High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. With the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable operating conditions, and this necessitates additional power beyond that used by the lamp itself. HID lamps offer important advantages compared to other lighting technologies, making them well suited for certain applications. HID lamps can be very efficient, have long operating lives, are relatively temperature-insensitive and produce a large quantity of light from a small package. For these reasons, HID lamps are often used when high levels of illumination are required over large areas and where operating and maintenance costs must be kept to a minimum. Furthermore, if the installation has a significant mounting height, high-power HID lamps can offer superior optical performance luminaires, reducing the number of lamps required to illuminate a given area. The indoor environments best suited to HID lamps are those with high ceilings, such as those commonly found in industrial spaces, warehouses, large retail spaces, sports halls and large public areas. Research into efficacy improvements for HID lighting technologies has generally followed market demand for these lamps, which is in decline for MV and LPS, has reached a plateau for HPS and is growing for MH. Several manufacturers interviewed for this study indicated that although solid-state lighting was now receiving the bulk of their company's R&D investment, there are still strong HID lamp research programs, which concentrate on MH technologies, with some limited amount of investment in HPS for specific niche applications (e.g., agricultural greenhouses). LPS and MV lamps are no longer being researched or improved in terms of efficacy or other performance attributes, although some consider MH HID lamps to be the next-generation MV lamp. Thus, the efficacy values of commercially available MV, LPS and HPS lamps are not expected to increase in the next 5 to 10 years. MH lamps, and more specifically, ceramic MH lamps are continuing to improve in efficacy as well as light quality, manufacturability and lamp life. Within an HID lamp, the light-producing plasma must be heated to sufficiently high temperatures to achieve high efficiencie

Scholand, Michael

2012-04-01T23:59:59.000Z

67

Solid-state lamp with integral occupancy sensor  

E-Print Network (OSTI)

Previous work demonstrated a retrofit proximity detector for fluorescent lamps using the lamp's own stray electric fields. This paper extends the retrofit sensor system to a solid-state (LED) lamp. The design and implementation ...

Cooley, John J.

68

Experimental methodology for determining the system performance of fluorescent lamp, ballast, fixture combinations operating under realistic application conditions  

SciTech Connect

To meet the need for accurate performance data, an experimental method for determining the performance of lamp, ballast, and luminaire combinations operating under a broad range of realistic conditions was developed. The methodology employs a two-part experimental procedure. The first part uses a temperature-controlled luminous flux integrator to characterize the thermal performance of each lamp/ballast combination. This performance characterization is expressed in terms of light output and efficacy as a function of variations in minimum lamp wall temperature (MLWT) and is generated for the range of temperatures typically encountered in interior lighting applications. The second procedure uses a luminaire/plenum simulator to determine the specific MLWT that exists in a particular luminaire application as a function of luminaire type, mounting configuration, plenum integration, and room air temperature. The MLWTs thus measured may be used in conjunction with the lamp/ballast performance data to determine application-specific values of light output and efficacy for a given lamp/ballast/luminaire system.

Siminovitch, M.J.; Rubinstein, F.M.; Verderber, R.R.

1984-11-01T23:59:59.000Z

69

Laboratory Evaluation of LED T8 Replacement Lamp Products  

Science Conference Proceedings (OSTI)

A report on a lab setting analysis involving LED lamps intended to directly replace T8 fluorescent lamps (4') showing light output, power, and economic comparisons with other fluorescent options.

Richman, Eric E.; Kinzey, Bruce R.; Miller, Naomi J.

2011-05-23T23:59:59.000Z

70

Fixture conditions affect lamp performance  

SciTech Connect

This article discusses the major parameters that affect fluorescent lamp performance under fixture conditions. These parameters include fixture type, and HVAC integration, which directly determine the minimum lamp wall temperature (MLWT), and therefore, the resulting light output of the lamp/ballast system. Experimental data is presented showing that the lumen output of the lamp/ballast system can vary by as much as 20% and that the system efficacy can vary by 10% depending upon the type of fixture and HVAC system employed. 4 refs., 5 figs., 1 tab.

Siminovitch, M.J.; Rubinstein, F.M.; Verderber, R.R.

1986-11-01T23:59:59.000Z

71

Energy Basics: Fluorescent Lighting  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Fluorescent Lighting Fluorescent lamps use 25%-35% of the energy used by incandescent lamps to provide the same amount of illumination (efficacy of 30-110 lumens per watt). They...

72

Aperture lamp  

DOE Patents (OSTI)

A discharge lamp includes means for containing a light emitting fill, the fill being capable of absorbing light at one wavelength and re-emitting the light at a different wavelength, the light emitted from the fill having a first spectral power distribution in the absence of reflection of light back into the fill; means for exciting the fill to cause the fill to emit light; and means for reflecting some of the light emitted by the fill back into the fill while allowing some light to exit, the exiting light having a second spectral power distribution with proportionately more light in the visible region as compared to the first spectral power distribution, wherein the light re-emitted by the fill is shifted in wavelength with respect to the absorbed light and the magnitude of the shift is in relation to an effective optical path length. Another discharge lamp includes an envelope; a fill which emits light when excited disposed in the envelope; a source of excitation power coupled to the fill to excite the fill and cause the fill to emit light; and a reflective ceramic structure disposed around the envelope and defining an light emitting opening, wherein the structure comprises a sintered body built up directly on the envelope and made from a combination of alumina and silica.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD)

2003-01-01T23:59:59.000Z

73

Section 5.4.1 Linear Fluorescent Lighting: Greening Federal Facilities...  

NLE Websites -- All DOE Office Websites (Extended Search)

and color temperature. When specifying a lighting sys- tem, be sure that the lamp and ballast are electrically matched and the lamp and fixture optically matched. Fluorescent lamp...

74

Lamp Divisions  

Office of Legacy Management (LM)

--- --- /A;; i :' r%i;in~house ilEc;' i:Z3:~cra:ion Lamp Divisions , _.. (I +i. 0 :,,,rg. . I . . -= i?e p/q! qe)-' &se pw E.rcale?l iev, Je!sey 07m March 20, 1 gs? ::r . J. A. Jones I ti. 5. Muclear Regulatory Commission .> = ..- haterials Licensing Branch -s - ,.I, - - Division of Fuel Cycle and hateri al Safety LY. , $2 - _ . ' -' . 3 _- - Yeshington, C. C. 2@555 - :_ :--, =-- -- .-?J -.: y...., : :- 7 Dear Mr. Jones : y-- --, ? . *I 2=15 2 r; X -P The following is our final report of the decontamination efZor?s takz in our Bui Iding 7 basement and wi 11 also serve to update our report i& November 12, 1980. As stated in NRC' s report of December 22, 1983, two closeout inspect ions were conducted by your King of Prussia off i ce on November 21 and December 2,

75

LED lamp  

SciTech Connect

There is herein described a lamp for providing white light comprising a plurality of light sources positioned on a substrate. Each of said light sources comprises a blue light emitting diode (LED) and a dome that substantially covers said LED. A first portion of said blue light from said LEDs is transmitted through said domes and a second portion of said blue light is converted into a red light by a first phosphor contained in said domes. A cover is disposed over all of said light sources that transmits at least a portion of said red and blue light emitted by said light sources. The cover contains a second phosphor that emits a yellow light in response to said blue light. The red, blue and yellow light combining to form the white light and the white light having a color rendering index (CRI) of at least about 80.

Galvez, Miguel; Grossman, Kenneth; Betts, David

2013-11-12T23:59:59.000Z

76

Portable lamp with dynamically controlled lighting distribution  

DOE Patents (OSTI)

A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) arranged vertically with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum insures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. The lighting system may be designed for the home, hospitality, office or other environments.

Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

2001-01-01T23:59:59.000Z

77

Fluorescent Lighting  

Energy.gov (U.S. Department of Energy (DOE))

Fluorescent lamps use 25%-35% of the energy used by incandescent lamps to provide the same amount of illumination (efficacy of 30-110 lumens per watt). They also last about 10 times longer (7,000-24,000 hours).

78

Ceiling Fan and Ceiling Fan Light Kit use in the U.S. Results of a Survey on Amazon Mechanical Turk  

E-Print Network (OSTI)

Ceiling Fan and Ceiling Fan Light Kit use in the U.S. —Ceiling Fan and Ceiling Fan Light Kit use in the U.S. —fans and ceiling fan light kits in the United States (

Kantner, Colleen L.S.

2013-01-01T23:59:59.000Z

79

Fluorescent fixtures and ballasts  

SciTech Connect

The basic parameters of a fluorescent lighting system that affect the illumination level are discussed. The parameters include the thermal performance of the fixture and the ballast factor, voltage regulation, and thermal regulation of the ballast/lamp system. Fixtures determine the minimum lamp-wall temperature of the lamps and are described as hot or cold. That is, the lamp-wall temperatures can vary from 39 to 61/sup 0/C. In general, cool fixtures tend to provide higher light levels and are more efficacious for a given ballast/lamp system. Solid-state fluorescent ballast/lamp systems have been measured and show a variation in light output from 6170 to 3780 lumens for the two-lamp, F-40, T-12, rapid-start lamps. Lighting designers must obtain this information in order to accurately predict illumination levels in a space.

Verderber, R.R.

1984-05-01T23:59:59.000Z

80

Potential Global Benefits of Improved Ceiling Fan Energy Efficiency  

NLE Websites -- All DOE Office Websites (Extended Search)

Global Benefits of Improved Ceiling Fan Energy Efficiency Title Potential Global Benefits of Improved Ceiling Fan Energy Efficiency Publication Type Report LBNL Report Number...

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Fluorescent Lighting | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fluorescent Lighting Fluorescent Lighting Fluorescent Lighting October 17, 2013 - 5:44pm Addthis Fluorescent Lighting Fluorescent Lighting Fluorescent lamps use 25%-35% of the energy used by incandescent products to provide a similar amount of light. They also last about 10 times longer (7,000-24,000 hours). The two general types of fluorescent lamps are: Compact fluorescent lamps (CFLs) -- commonly found with integral ballasts and screw bases, these are popular lamps often used in household fixtures Fluorescent tube and circline lamps -- typically used for task lighting such as garages and under cabinet fixtures, and for lighting large areas in commercial buildings. CFLs CFLs combine the energy efficiency of fluorescent lighting with the convenience and popularity of incandescent fixtures. CFLs fit most fixtures

82

COST EFFECTIVENESS OF LONG LIFE INCANDESCENT LAMPS AND ENERGY BUTTONS  

E-Print Network (OSTI)

button, a 100 watt (130 volt) lamp, a 100 watt long lifeFluorescent Watt L I ltage (volts) cu ge ic in s) ative ( 1the diode energy button (83 volts) was obtained by dividing

Verderber, Rudy

2013-01-01T23:59:59.000Z

83

Jacketed lamp bulb envelope  

DOE Patents (OSTI)

A jacketed lamp bulb envelope includes a ceramic cup having an open end and a partially closed end, the partially closed end defining an aperture, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material at least partially covering a portion of the bulb not abutting the aperture. The reflective ceramic material may substantially fill an interior volume of the ceramic cup not occupied by the bulb. The ceramic cup may include a structural feature for aiding in alignment of the jacketed lamp bulb envelope in a lamp. The ceramic cup may include an external flange about a periphery thereof. One example of a jacketed lamp bulb envelope includes a ceramic cup having an open end and a closed end, a ceramic washer covering the open end of the ceramic cup, the washer defining an aperture therethrough, a lamp bulb positioned inside the ceramic cup abutting the aperture, and a reflective ceramic material filling an interior volume of the ceramic cup not occupied by the bulb. A method of packing a jacketed lamp bulb envelope of the type comprising a ceramic cup with a lamp bulb disposed therein includes the steps of filling the ceramic cup with a flowable slurry of reflective material, and applying centrifugal force to the cup to pack the reflective material therein.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Gitsevich, Aleksandr (Gaithersburg, MD); Bass, Gary K. (Mt. Airy, MD); Dolan, James T. (Frederick, MD); Kipling, Kent (Gaithersburg, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Leng, Yongzhang (Damascus, MD); Levin, Izrail (Silver Spring, MD); Roy, Robert J. (Frederick, MD); Shanks, Bruce (Gaithersburg, MD); Smith, Malcolm (Alexandria, VA); Trimble, William C. (Columbia, MD); Tsai, Peter (Olney, MD)

2001-01-01T23:59:59.000Z

84

Ceiling Fan and Ceiling Fan Light Kit use in the U.S. Results of a Survey on Amazon Mechanical Turk  

E-Print Network (OSTI)

Intellect, LLC (2011). Ceiling fan consumer survey data fromconsumption from ceiling fans. 5 References Amazon.com. (January/February 2001). Ceiling fans: Fulfilling the energy

Kantner, Colleen L.S.

2013-01-01T23:59:59.000Z

85

Royal Pacific: Order (2013-SE-33004) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

various basic models of medium base compact fluorescent lamps, ceiling fans, ceiling fan light kits, and illuminated exit signs comply with the applicable energy conservation...

86

Ceiling and Visibility Forecasts via Neural Networks  

Science Conference Proceedings (OSTI)

Statistical postprocessing of numerical model output can improve forecast quality, especially when model output is combined with surface observations. In this article, the development of nonlinear postprocessors for the prediction of ceiling and ...

Caren Marzban; Stephen Leyton; Brad Colman

2007-06-01T23:59:59.000Z

87

Solid-State Lighting: LED Replacements for Linear Fluorescent...  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Replacements for Linear Fluorescent Lamps Webcast to someone by E-mail Share Solid-State Lighting: LED Replacements for Linear Fluorescent Lamps Webcast on Facebook Tweet about...

88

CALIFORNIA ENERGY Integrated Ceiling Research Report  

E-Print Network (OSTI)

for advanced ceiling systems that: · Provides excellent lighting and daylighting quality, thermal comfort McConocha of Federated Departments, JimVan Dame of My-Lite Daylighting Systems and Products, Doug Departments, JimVan Dame of My-Lite Daylighting Systems and Products, Doug Gehring of Celotex, Ivan Johnson

89

2X Incandescent Lamp Technology  

Science Conference Proceedings (OSTI)

The incandescent lamp was developed during the 1800s, largely reaching the design of the traditional incandescent lamp as we know it by the late 1800s. This lamp remained largely unchanged for years, providing most commercial and residential lighting demands into the 1950s and residential lighting into the 2000s. As new lighting technologies became available, the low efficacy, measured in lumens per watt, of the traditional incandescent lamp became an issue which many wanted to ...

2012-11-01T23:59:59.000Z

90

Development of a High Efficiency Ceiling Fan  

E-Print Network (OSTI)

The potential of ceiling fans to improve comfort during the cooling season is well documented (Rohles et al.. 1983; Fairey et al.. 1986). There are at least two cases: In the first where air conditioning is unavailable, adding ceiling fans may significantly improve building comfort and health although actually increasing energy use. However, the more common circumstance is where ceiling fans are used with the objective of providing a higher cooling system thermostat set point with acceptable comfort. Fans can also potentially avoid the use of air conditioning during "swing" seasons. Although studies commonly suggest a 2-6OF increase in the thermostat set point, data from 386 surveyed Central Florida households suggests that although fans are used an average of 13.4 hours per day, no statistically valid difference can be observed in thermostat settings between households using fans and those without them (James et al., 1996). Part of this may be due to the lack of sufficiently wide air distribution coverage within rooms (Rohles et al, 1983; Sonne and Parker, 1998). Studies touting potential cooling savings of up to 40% have usually been sponsored by fan manufacturers (eg. A.D. Little, 1981). These often make unrealistic assumptions such as presuming that occupants are within four feet of a fan with only one fan in use and a 6°F elevation of the thermostat setting. An environmental chamber study by Consumer Reports showed that the long-reported de-stratification benefits when heating are largely unsubstantiated (Consumer Reports. 1993). Thus. benefits from ceiling fans are only to reduce cooling needs and this is completely contingent on sufficient changes in interior comfort to warrant raising of the cooling thermostat. Two other factors must be taken into account in assessing the benefits of fans: their actual energy use and the added internal heat gains produced by the fans during operation. The measured electrical demand of ceiling fans varies between 5 and 115 Watts depending on model and speed selection. A power demand of 40 W at medium speed is probably typical (Chandra, 1985). Thus, a fan used for six months of the year would use 175 kwh. With 4.3 ceiling fans in an average Florida home, this amounts to about 800 kwh of fan energy consumption --about 5% of total electricity use. Also, all of the energy use of fans is eventually converted to heat within the home which must eventually be removed by ventilation air or the cooling system.

Parker, D. S.; Callahan, M. P.; Sonne, J. K.; Su, G. H.; Hibbs, B. D.

2000-01-01T23:59:59.000Z

91

DuraLamp USA: Proposed Penalty (2010-CE-0912) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DuraLamp USA: Proposed Penalty (2010-CE-0912) DuraLamp USA: Proposed Penalty (2010-CE-0912) DuraLamp USA: Proposed Penalty (2010-CE-0912) September 9, 2010 DOE alleged in a Notice of Proposed Civil Penalty that DuraLamp USA, Inc. failed to certify a variety of general service fluorescent lamps as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. DuraLamp USA: Proposed Penalty (2010-CE-0912) More Documents & Publications DuraLamp USA: Order (2010-CE-0912)

92

New LED light sources and lamps for general illumination  

E-Print Network (OSTI)

of light source compared to traditional light sources like incandescent bulbs and fluorescent tubes bulb. LEDs emit colored light with a narrow spectral band of 20-30 nm, colors covering the spectralNew LED light sources and lamps for general illumination Carsten Dam-Hansen, Birgitte Thestrup

93

Modeling thermal comfort with radiant floors and ceilings  

E-Print Network (OSTI)

limits for heated ceilings. ASHRAE Transactions 86(2): 141-Radiation and discomfort. ASHRAE Journal Griffiths, I. S.active human sub- jects. ASHRAE Transactions 74: 131 -143.

2009-01-01T23:59:59.000Z

94

Characteristics of Residential Housing Units by Ceiling Fans, 2001  

U.S. Energy Information Administration (EIA)

A reporting of the number of housing units using ceiling fans in U.S. households as reported in the 2001 Residential Energy Consumption Survey

95

Table 1. Household Characteristics by Ceiling Fans, 2001  

U.S. Energy Information Administration (EIA)

A reporting of the number of housing units using ceiling fans in U.S. households as reported in the 2001 Residential Energy Consumption Survey

96

title Potential Global Benefits of Improved Ceiling Fan Energy...  

NLE Websites -- All DOE Office Websites (Extended Search)

Fan Energy Efficiency year month keywords bottom up Ceiling fan Celing Fans efficiency energy efficiency Financial incentives Market Transformation residential Standards and...

97

Inductive tuners for microwave driven discharge lamps  

DOE Patents (OSTI)

An RF powered electrodeless lamp utilizing an inductive tuner in the waveguide which couples the RF power to the lamp cavity, for reducing reflected RF power and causing the lamp to operate efficiently.

Simpson, James E. (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

98

Information Resources: LED Replacement Lamps: Current Performance...  

NLE Websites -- All DOE Office Websites (Extended Search)

incandescent lamps (e.g., A-lamps), and provided an update on ENERGY STAR criteria for LED integral replacement lamps - currently in its second draft. Robert Lingard of Pacific...

99

Energy efficiency lighting on board naval ships: Phase 2 (The T-8 lamp system)  

SciTech Connect

This report describes the development and performance of the T-8 fluorescent lamp-ballast system. Similar to the Phase I effort, the cooperation of the lamp and ballast companies (GTE, North American Philips Lighting, and IOTA Engineering) were required for the successful result. The above companies submitted prototype lamps and ballasts to the Lawrence Berkeley Laboratory Lighting Group to evaluate. The lamp designs were modified as required and the optimum system selected. Two-lamp designs and one ballast were chosen and tested to determine if they met the Navy specifications. The second section describes the lamp-ballast specifications. This section includes the measured thermal performance from an ambient of 10/degree/C to 60/degree/C. 1 ref., 8 figs., 11 tabs.

Verderber, R.R.

1987-01-31T23:59:59.000Z

100

Identification of lamp ballasts containing PCBs. Revised edition. Report no. EPS 2/CC/2  

SciTech Connect

Fluorescent lamp ballast capacitors are among the products that may contain polychlorinated biphenyls (PCBs). Questions about lamp ballasts concern the potential for leakage, the risk of heating and exploding, how to identify a ballast which contains PCBs, and the risk to human health. This study identifies those ballasts containing PCB-filled capacitors; the domestic and foreign manufacturers of PCB-containing ballasts; the total quantity of PCBs used in ballasts; and any potential problems. The study does not identify the risks of human health arising from the use of PCB-ballasts in fluorescent lamps.

1991-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

A projective LED dental lamp design.  

E-Print Network (OSTI)

??Halogen lamps are mostly applied as a light source to the traditional lamp for medical treatment due to its proper color temperature, but it has… (more)

Chung, Yu-Lin

2011-01-01T23:59:59.000Z

102

Costs and benefits of energy efficiency improvements in ceiling fans  

SciTech Connect

Ceiling fans contribute significantly to residential electricity consumption, especially in developing countries with warm climates. The paper provides analysis of costs and benefits of several options to improve the efficiency of ceiling fans to assess the global potential for electricity savings and green house gas (GHG) emission reductions. Ceiling fan efficiency can be cost-effectively improved by at least 50% using commercially available technology. If these efficiency improvements are implemented in all ceiling fans sold by 2020, 70 terawatt hours per year could be saved and 25 million metric tons of carbon dioxide equivalent (CO2-e) emissions per year could be avoided, globally. We assess how policies and programs such as standards, labels, and financial incentives can be used to accelerate the adoption of efficient ceiling fans in order to realize potential savings.

Shah, Nihar; Sathaye, Nakul; Phadke, Amol; Letschert, Virginie [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division] [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

2013-10-15T23:59:59.000Z

103

History and technical evolution of high frequency fluorescent lighting  

SciTech Connect

This work was performed to accelerate development and commercialization of solid-state, high frequency ballasts for fluorescent lighting systems. The history and development of fluorescent lamps, of ballasts for these fixtures, and of related circuits and equipment are reviewed. The higher lamp efficiency of high-frequency (300 to 3000 Hz) fluorescent lamps as compared with 60 Hz lamps, the development of frequency converter circuits for high-frequency lamps, and uses, electrical characteristics, and economics of these lighting systems are discussed. (LCL)

Campbell, J.H.

1977-12-01T23:59:59.000Z

104

Transmission of sound through suspended ceilings from HVAC terminal units  

Science Conference Proceedings (OSTI)

An ASHRAE project to investigate factors determining the sound pressure levels in rooms below ceilings concealing air?terminal units has been completed. Four terminal units installed close to the six ceiling types used were the major noise sources. They were supplemented by two simulators powered by loudspeakers.Sound power was measured for each device in the 156 cubic meter test room in its reverberant condition. The levels in the room were measured for each combination of source and ceiling tile. Sound pressure level was measured as a function of distance from two sources in the room below. The main intent of the project was to validate ARI Standard 885 which provides a calculation method for such situations. Differences among ceiling types were less than expected; leakage around the edges of each panel is a dominant transmission path. Ceiling attenuations at low frequencies were found to depend on the area of the lower face of the units. Sound levels in the room were essentially uniform when the source was above the ceiling. The decay of sound with distance from the sources below the ceiling was found to depend on the inverse of the room reverberation time.

Alf Warnock

1998-01-01T23:59:59.000Z

105

Table lamp with dynamically controlled lighting distribution and uniformly illuminated luminous shade  

DOE Patents (OSTI)

A double lamp table or floor lamp lighting system has a pair of compact fluorescent lamps (CFLs) or other lamps arranged vertically, i.e. one lamp above the other, with a reflective septum in between. By selectively turning on one or both of the CFLs, down lighting, up lighting, or both up and down lighting is produced. The control system can also vary the light intensity from each CFL. The reflective septum ensures that almost all the light produced by each lamp will be directed into the desired light distribution pattern which is selected and easily changed by the user. In a particular configuration, the reflective septum is bowl shaped, with the upper CFL sitting in the bowl, and a luminous shade hanging down from the bowl. The lower CFL provides both task lighting and uniform shade luminance. Planar compact fluorescent lamps, e.g. circular CFLs, particularly oriented horizontally, are preferable. CFLs provide energy efficiency. However, other types of lamps, including incandescent, halogen, and LEDs can also be used in the fixture. The lighting system may be designed for the home, hospitality, office or other environments.

Siminovitch, Michael J. (Pinole, CA); Page, Erik R. (Berkeley, CA)

2002-01-01T23:59:59.000Z

106

List of Ceiling Fan Incentives | Open Energy Information  

Open Energy Info (EERE)

Fan Incentives Fan Incentives Jump to: navigation, search The following contains the list of 99 Ceiling Fan Incentives. CSV (rows 1 - 99) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio (Electric) - Residential Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Residential Building Insulation Ceiling Fan Central Air conditioners Custom/Others pending approval Duct/Air sealing Heat pumps Lighting Motors Programmable Thermostats Windows Yes AEP Ohio (Gas) - Residential Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Residential Building Insulation Ceiling Fan Central Air conditioners Custom/Others pending approval Dehumidifiers Duct/Air sealing Heat pumps Lighting Motors Programmable Thermostats

107

Remote Cloud Ceiling Assessment Using Data-Mining Methods  

Science Conference Proceedings (OSTI)

Data-mining methods are applied to numerical weather prediction (NWP) output and satellite data to develop automated algorithms for the diagnosis of cloud ceiling height in regions where no local observations are available at analysis time. A ...

Richard L. Bankert; Michael Hadjimichael; Arunas P. Kuciauskas; William T. Thompson; Kim Richardson

2004-12-01T23:59:59.000Z

108

Issues, Models and Solutions for Triac Modulated Phase Dimming of LED Lamps  

E-Print Network (OSTI)

/a 30 lumens 0.1 Incandescent Bulb 15 W 225 lumens 15 Fluorescent Tube Lamp 10 W 500 lumens 50 White LED bulbs, and fluorescent lights, produce light that is radiated in all directions, LEDs produce a focused especially on the potential of white LED lights, which are an important and newly emerging lighting

Lehman, Brad

109

Electronic screw-in ballast and improved circline lamp phase I. Final report  

SciTech Connect

A solid state ballast has been designed for the efficient operation of a 10 in circline fluorescent lamp. The circuit can be manufactured using power hybrid technology. Eight discrete component versions of the ballasts have been delivered to LBL for testing. The results show the solid state fluorescent ballast system is more efficient than the core-coil ballasted systems on the market.

Kohler, T.P.

1980-09-01T23:59:59.000Z

110

Fluorescent Lighting Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fluorescent Lighting Basics Fluorescent Lighting Basics Fluorescent Lighting Basics October 17, 2013 - 5:39pm Addthis Light from a fluorescent lamp is first created by an electric current conducted through an inert gas producing ultraviolet light that is invisible to the human eye. The ultraviolet light in turn interacts with special blends of phosphors coating the interior surface of the fluorescent lamp tube that efficiently converts the invisible light into useful white light. Fluorescent lamps require a special power supply called a ballast that is needed to regulate lamp operating current and provide a compatible start-up voltage. Electronic ballasts perform the same function as a magnetic ballast but outperform the outdated magnetic products by operating at a very high frequency that eliminates flicker and noise while

111

Record of Communication Concerning Ceiling Fan and Ceiling Fan Light Kit Framework Document—Docket No. EERE-2012-BT-STD-0045  

Energy.gov (U.S. Department of Energy (DOE))

This memo provides an overview of communications made to DOE staff on the subject of possible changes to standards and test procedures for ceiling fans and ceiling fan light kits.

112

Ceiling Fan and Ceiling Fan Light Kit use in the U.S. Results of a Survey on Amazon Mechanical Turk  

E-Print Network (OSTI)

air conditioning .31   3.7   Impact of ceiling fans on air conditioningowners increased the air conditioning thermostat temperature

Kantner, Colleen L.S.

2013-01-01T23:59:59.000Z

113

Commercial Air Barrier Requirements for Insulated Ceilings - Code Notes |  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Barrier Requirements for Insulated Ceilings - Code Notes Air Barrier Requirements for Insulated Ceilings - Code Notes The 2009 International Energy Conservation Code requires openings in the building envelope to be sealed to prevent air leakage into and out of the space, including an air barrier at insulation installations. Publication Date: Wednesday, June 22, 2011 cn_commercial_air_barrier_requirements_for_insulated_ceilings.pdf Document Details Prepared by: Pacific Northwest National Laboratory for the U.S. Department of Energy Building Energy Codes Program Focus: Compliance Building Type: Commercial Code Referenced: ASHRAE Standard 90.1-2007 2009 IECC Document type: Code Notes Target Audience: Architect/Designer Builder Code Official Contractor Engineer Contacts Web Site Policies U.S. Department of Energy USA.gov Last Updated: Thursday, September 20, 2012 - 17:25

114

Data Mining Numerical Model Output for Single-Station Cloud-Ceiling Forecast Algorithms  

Science Conference Proceedings (OSTI)

Accurate cloud-ceiling-height forecasts derived from numerical weather prediction (NWP) model data are useful for aviation and other interests where low cloud ceilings have an impact on operations. A demonstration of the usefulness of data-mining ...

Richard L. Bankert; Michael Hadjimichael

2007-10-01T23:59:59.000Z

115

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology  

SciTech Connect

The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

Not Available

1993-11-01T23:59:59.000Z

116

Measurement of Absorption in Rooms with Sound Absorbing Ceilings  

Science Conference Proceedings (OSTI)

Serious difficulties have been encountered in attempts to measure the absorption coefficients of sound absorbing ceilings in large offices. An analysis of the sound field is made and it is concluded (1) that the reverberation time formula is usually invalid if the absorption is concentrated on one surface of the room

J. R. Power

1938-01-01T23:59:59.000Z

117

Application guidance for fluorescent lighting projects  

SciTech Connect

This application guides is intended to help activity personnel retrofit fluorescent lighting. With this guide, an energy manager can determine if replacing T-12 lamp and magnetic ballast fixtures is cost effective.

Rocha, M.

1994-06-01T23:59:59.000Z

118

Lamp bulb with integral reflector  

SciTech Connect

An improved electrodeless discharge lamp bulb includes an integral ceramic reflector as a portion of the bulb envelope. The bulb envelope further includes two pieces, a reflector portion or segment is cast quartz ceramic and a light transmissive portion is a clear fused silica. In one embodiment, the cast quartz ceramic segment includes heat sink fins or stubs providing an increased outside surface area to dissipate internal heat. In another embodiment, the quartz ceramic segment includes an outside surface fused to eliminate gas permeation by polishing.

Levin, Izrail (Silver Spring, MD); Shanks, Bruce (Gaithersburg, MD); Sumner, Thomas L. (Wheaton, MD)

2001-01-01T23:59:59.000Z

119

Modification of fluorescent luminaries for energy conservation  

SciTech Connect

Reducing energy consumption in existing buildings by reducing the number of lamps presents technical problems when more than one fluorescent lamp operates from a single ballast. A preliminary investigation was made whereby capacitors were substituted for one fluorescent lamp in a two-lamp luminaire which operated with a single ballast. Under optimum conditions, lighting efficiency (foot-candles per watt) was nearly as high at reduced power input as it was with two lamps operating normally. No failures in lighting equipment or capacitors occurred and no fire hazards, other safety hazards, or other unsatisfactory occurrences were observed. A more thorough investigation involving a number of parameters is needed to ascertain the feasibility of this modification.

Beausoliel, R.W.; Meese, W.J.; Yonemura, G.

1975-01-01T23:59:59.000Z

120

Modification of fluorescent luminaires for energy conservation  

SciTech Connect

Reducing energy consumption in existing buildings by reducing the number of lamps presents technical problems when more than one fluorescent lamp operates from a single ballast. A preliminary investigation was made whereby capacitors were substituted for one fluorescent lamp in a two-lamp luminaire which operated with a single ballast. Under optimum conditions, lighting efficiency (foot-candles per watt) was nearly as high at reduced power input as it was with two lamps operating normally. No failures in lighting equipment or capacitors occurred and no fire hazards, other safety hazards, or other unsatisfactory occurrences were observed. A more thorough investigation involving a number of parameters is needed to ascertain the feasibility of this modification. (auth)

Beausoliel, R.W.; Meese, W.J.; Yonemura, G.

1975-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Discharge lamp with reflective jacket  

DOE Patents (OSTI)

A discharge lamp includes an envelope, a fill which emits light when excited disposed in the envelope, a source of excitation power coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed around the envelope and defining an opening, the reflector being configured to reflect some of the light emitted by the fill back into the fill while allowing some light to exit through the opening. The reflector may be made from a material having a similar thermal index of expansion as compared to the envelope and which is closely spaced to the envelope. The envelope material may be quartz and the reflector material may be either silica or alumina. The reflector may be formed as a jacket having a rigid structure which does not adhere to the envelope. The lamp may further include an optical clement spaced from the envelope and configured to reflect an unwanted component of light which exited the envelope back into the envelope through the opening in the reflector. Light which can be beneficially recaptured includes selected wavelength regions, a selected polarization, and selected angular components.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Kipling, Kent (Gaithersburg, MD)

2001-01-01T23:59:59.000Z

122

DuraLamp USA: Order (2010-CE-0912)  

Energy.gov (U.S. Department of Energy (DOE))

DOE ordered DuraLamp USA, Inc. to pay a $2,500 civil penalty after finding DuraLamp USA had failed to certify that model PAR 30, an incandescent reflector lamp, complies with the applicable energy conservation standards.

123

Solar passive ceiling system. Final report. [Passive solar heating system with venetian blind reflectors and latent heat storage in ceiling  

DOE Green Energy (OSTI)

The construction of a 1200 square foot building, with full basement, built to be used as a branch library in a rural area is described. The primary heating source is a passive solar system consisting of a south facing window system. The system consists of: a set of windows located in the south facing wall only, composed of double glazed units; a set of reflectors mounted in each window which reflects sunlight up to the ceiling (the reflectors are similar to venetian blinds); a storage area in the ceiling which absorbs the heat from the reflected sunlight and stores it in foil salt pouches laid in the ceiling; and an automated curtain which automatically covers and uncovers the south facing window system. The system is totally passive and uses no blowers, pumps or other active types of heat distribution equipment. The building contains a basement which is normally not heated, and the north facing wall is bermed four feet high around the north side.

Schneider, A.R.

1980-01-01T23:59:59.000Z

124

Driver Circuit for White LED Lamps with TRIAC Dimming Control.  

E-Print Network (OSTI)

??An efficient Light Emitting Diode (LED) lamp driver circuit is proposed for retrofitting the conventionally used incandescent lamps with existing TRIAC dimmer. The dimming feature… (more)

Weng, Szu-Jung

2012-01-01T23:59:59.000Z

125

Lamp system for uniform semiconductor wafer heating  

SciTech Connect

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, Luis E. (Livermore, CA); Hackel, Lloyd (Livermore, CA)

2001-01-01T23:59:59.000Z

126

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

in distribution transformers for power factor correction.of the power factors at the distribution transformers, or at

Gadgil, A.J.

2008-01-01T23:59:59.000Z

127

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

representative electricity prices, because the residentialand 11. The range of electricity prices shown in the Figs.between mar- ginal electricity prices and residential tariff

Gadgil, A.J.

2008-01-01T23:59:59.000Z

128

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

and commercial electricity tariffs in each country. Noticemar- ginal electricity prices and residential tariff~. Anelectricity prices, because the residential tariff structure

Gadgil, A.J.

2008-01-01T23:59:59.000Z

129

Zero energy-storage ballast for compact fluorescent lamps  

DOE Patents (OSTI)

A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast. 4 figs.

Schultz, W.N.; Thomas, R.J.

1999-08-31T23:59:59.000Z

130

Recycling of Fluorescent Lamp Glass into Clayey Ceramic  

Science Conference Proceedings (OSTI)

Designing a Collaborative System for Socio-Environmental Management of ... Oils Post-Consumption Residential and Commercial Clay with Two Brazilian.

131

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

1.7% of in- stalled hydroelectric capacity. Op. cit. ref [in Ig86) based on hydroelectric generation, and most of thethe still abundant hydroelectric potential of the country.

Gadgil, A.J.

2008-01-01T23:59:59.000Z

132

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

the functions of generation and distribution are separated,undertake generation, transmission, and distribution (e.g.paid by the distribution utility to the generation utility.

Gadgil, A.J.

2008-01-01T23:59:59.000Z

133

Conservation Potential of Compact Fluorescent Lamps in India and Brazil  

E-Print Network (OSTI)

1988. The private sector in Brazil owned (in 1986) 40% ofElectricity Conservation in Brazil: Potential and Pro-electricity consumption in Brazil's residential sector was

Gadgil, A.J.

2008-01-01T23:59:59.000Z

134

Phosphor blends for high-CRI fluorescent lamps  

DOE Patents (OSTI)

A phosphor blend comprises at least two phosphors each selected from one of the groups of phosphors that absorb UV electromagnetic radiation and emit in a region of visible light. The phosphor blend can be applied to a discharge gas radiation source to produce light sources having high color rendering index. A phosphor blend is advantageously includes the phosphor (Tb,Y,LuLa,Gd).sub.x(Al,Ga).sub.yO.sub.12:Ce.sup.3+, wherein x is in the range from about 2.8 to and including 3 and y is in the range from about 4 to and including 5.

Setlur, Anant Achyut (Niskayuna, NY); Srivastava, Alok Mani (Niskayuna, NY); Comanzo, Holly Ann (Niskayuna, NY); Manivannan, Venkatesan (Clifton Park, NY); Beers, William Winder (Chesterland, OH); Toth, Katalin (Pomaz, HU); Balazs, Laszlo D. (Budapest, HU)

2008-06-24T23:59:59.000Z

135

Characterization of Fluorescent Lamp Glass Waste Powders for ...  

Science Conference Proceedings (OSTI)

The glass waste presents favorable characteristics for incorporation into clayey ceramic ... Codin, Located in Campos (RJ), to Produce Soil-Cement Blocks.

136

Zero energy-storage ballast for compact fluorescent lamps  

DOE Patents (OSTI)

A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast.

Schultz, William Newell (Niskayuna, NY); Thomas, Robert James (Rexford, NY)

1999-01-01T23:59:59.000Z

137

Electronic Fluorescent Lamp Ballasts Used in 4-Foot Fixtures  

Science Conference Proceedings (OSTI)

This power quality (PQ) case study presents tests performed at the EPRI Power Electronics Applications Center (PEAC) Power Quality Test Facility to characterize ballast energy performance, emissions, and immunity from a PQ perspective.

2003-12-31T23:59:59.000Z

138

An integral model for turbulent flame radial lengths under a ceiling.  

E-Print Network (OSTI)

?? An analytical study using an integral model for turbulent flame radial lengths under a ceiling is presented. Dimensionless equations give results in terms of… (more)

Ding, Haiwen

2010-01-01T23:59:59.000Z

139

LED lamp power management system and method  

DOE Patents (OSTI)

An LED lamp power management system and method including an LED lamp having an LED controller 58; a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 reduces power loss in one of the channel switch 62 and the shunt switch 68 when LED lamp electronics power loss (P.sub.loss) exceeds an LED lamp electronics power loss limit (P.sub.lim); and each of the channel switches 62 receives a channel switch control signal 63 from the LED controller 58 and each of the shunt switches 68 receives a shunt switch control signal 69 from the LED controller 58.

Gaines, James; Clauberg, Bernd; Van Erp, Josephus A. M.

2013-03-19T23:59:59.000Z

140

High frequency inductive lamp and power oscillator  

DOE Patents (OSTI)

A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and/or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency. Various control circuits may be employed to match the driving frequency of the oscillator to a plurality of tuning states of the lamp.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD); Dolan, James T. (Frederick, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Leng, Yongzhang (Damascus, MD)

2000-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

How Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? How Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? September 23, 2010 - 7:30am Addthis On Monday, Chris told you about his new ceiling fan and how it's changed the way he cools his home. In warm weather, ceiling fans cool people (not rooms) by producing a wind-chill effect-which is why you should turn off fans when you leave the room. A ceiling fan allows you to raise the thermostat setting about 4°F with no reduction in comfort. Ceiling fans don't just cool in the summer; you can also reverse the direction in the winter to provide an updraft and force warm air down into the room. How has a ceiling fan affected the way you heat and cool your home? Each Thursday, you have the chance to share your thoughts on a question

142

How Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? How Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? September 23, 2010 - 7:30am Addthis On Monday, Chris told you about his new ceiling fan and how it's changed the way he cools his home. In warm weather, ceiling fans cool people (not rooms) by producing a wind-chill effect-which is why you should turn off fans when you leave the room. A ceiling fan allows you to raise the thermostat setting about 4°F with no reduction in comfort. Ceiling fans don't just cool in the summer; you can also reverse the direction in the winter to provide an updraft and force warm air down into the room. How has a ceiling fan affected the way you heat and cool your home? Each Thursday, you have the chance to share your thoughts on a question

143

High frequency inductive lamp and power oscillator  

DOE Patents (OSTI)

A high frequency inductively coupled electrodeless lamp includes an excitation coil with an effective electrical length which is less than one half wavelength of a driving frequency applied thereto, preferably much less. The driving frequency may be greater than 100 MHz and is preferably as high as 915 MHz. Preferably, the excitation coil is configured as a non-helical, semi-cylindrical conductive surface having less than one turn, in the general shape of a wedding ring. At high frequencies, the current in the coil forms two loops which are spaced apart and parallel to each other. Configured appropriately, the coil approximates a Helmholtz configuration. The lamp preferably utilizes an bulb encased in a reflective ceramic cup with a pre-formed aperture defined therethrough. The ceramic cup may include structural features to aid in alignment and I or a flanged face to aid in thermal management. The lamp head is preferably an integrated lamp head comprising a metal matrix composite surrounding an insulating ceramic with the excitation integrally formed on the ceramic. A novel solid-state oscillator preferably provides RF power to the lamp. The oscillator is a single active element device capable of providing over 70 watts of power at over 70% efficiency. Various control circuits may be employed to adjust the driving frequency of the oscillator.

MacLennan, Donald A. (Gaithersburg, MD); Dymond, Jr., Lauren E. (North Potomac, MD); Gitsevich, Aleksandr (Montgomery Village, MD); Grimm, William G. (Silver Spring, MD); Kipling, Kent (Gaithersburg, MD); Kirkpatrick, Douglas A. (Great Falls, VA); Ola, Samuel A. (Silver Spring, MD); Simpson, James E. (Gaithersburg, MD); Trimble, William C. (Columbia, MD); Tsai, Peter (Olney, MD); Turner, Brian P. (Damascus, MD)

2001-01-01T23:59:59.000Z

144

Energy Savings and NOx Emissions Reduction Potential from the 2012 Federal Legislation to Phase Out Incandescent Lamps in Texas  

E-Print Network (OSTI)

This report provides detailed information about the potential savings from the 2012 Federal Legislation to phase out incandescent lamps and the NOx emissions reduction from the replacement of incandescent bulbs with Compact Fluorescent Lamps (CFL). In Texas, this analysis includes the savings estimates from both the annual and Ozone Season Day (OSD) NOx reductions. The NOx emissions reduction in this analysis are calculated using estimated emissions factors for 2007 from the US Environmental Protection Agency (US EPA) eGRID database, which had been specially prepared for this purpose.

Liu, Zi; Baltazar, Juan Carlos; Haberl, Jeff; Soman, Rohit

2010-03-01T23:59:59.000Z

145

An Automated, Observations-Based System for Short-Term Prediction of Ceiling and Visibility  

Science Conference Proceedings (OSTI)

Several methods of generating very short term (0–6 h) probabilistic forecasts of ceiling and visibility are investigated: 1) an observations-based (OBS-based) system in which potential predictors consist of weather observations from a network of ...

Robert L. Vislocky; J. Michael Fritsch

1997-03-01T23:59:59.000Z

146

Aircraft Icing Environment in Low Ceiling Conditions near Washington, D.C.  

Science Conference Proceedings (OSTI)

Radiosonde temperature and humidity data were used to deduce the vertical distribution of clouds and aircraft icing conditions near Washington, D.C. when low ceilings occurred with surface temperatures near freezing. Twenty-three soundings from ...

Nathaniel B. Guttman; Richard K. Jeck

1987-06-01T23:59:59.000Z

147

A Fuzzy Logic–Based Analog Forecasting System for Ceiling and Visibility  

Science Conference Proceedings (OSTI)

WIND-3 is an application for aviation weather forecasting that uses the analog method to produce deterministic predictions of cloud ceiling height and horizontal visibility at airports. For data, it uses historical and current airport ...

Bjarne Hansen

2007-12-01T23:59:59.000Z

148

Cloud Signals from Lidar and Rotating Beam Ceilometer Compared with Pilot Ceiling  

Science Conference Proceedings (OSTI)

Cloud signals from a vertically pointing, range-corrected ruby lidar and a rotating beam ceilometer showed excellent agreement in the height at which peak signal occurred. However, pilot reports of ceiling were at significantly lower altitude ...

W. L. Eberhard

1986-09-01T23:59:59.000Z

149

Short-Term Probabilistic Forecasts of Ceiling and Visibility Utilizing High-Density Surface Weather Observations  

Science Conference Proceedings (OSTI)

An automated statistical system that utilizes regional high-density surface observations to forecast low ceiling and visibility events in the upper Midwest is presented. The system is based solely upon surface observations as predictors, ...

Stephen M. Leyton; J. Michael Fritsch

2003-10-01T23:59:59.000Z

150

Controlling the vapor pressure of a mercury lamp  

DOE Patents (OSTI)

The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled.

Grossman, Mark W. (Belmont, MA); George, William A. (Rockport, MA)

1988-01-01T23:59:59.000Z

151

Controlling the vapor pressure of a mercury lamp  

DOE Patents (OSTI)

The invention described herein discloses a method and apparatus for controlling the Hg vapor pressure within a lamp. This is done by establishing and controlling two temperature zones within the lamp. One zone is colder than the other zone. The first zone is called the cold spot. By controlling the temperature of the cold spot, the Hg vapor pressure within the lamp is controlled. Likewise, by controlling the Hg vapor pressure of the lamp, the intensity and linewidth of the radiation emitted from the lamp is controlled. 2 figs.

Grossman, M.W.; George, W.A.

1988-05-24T23:59:59.000Z

152

LED lamp color control system and method  

DOE Patents (OSTI)

An LED lamp color control system and method including an LED lamp having an LED controller 58; and a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 determines whether the LED source 80 is in a feedback controllable range, stores measured optical flux for the LED source 80 when the LED source 80 is in the feedback controllable range, and bypasses storing the measured optical flux when the LED source 80 is not in the feedback controllable range.

Gaines, James; Clauberg, Bernd; Van Erp, Josephus A.M.

2013-02-05T23:59:59.000Z

153

Lighting Group: Sources and Ballasts: LED Reflector Lamp  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Reflector Lamp LED Reflector Lamp LED Reflector Lamp Objective LED reflector lamp The goal of this project is to develop a revolutionary new reflector lamp which offers many advantages over current incandescent reflector lamps, including: three times greater efficiency ten times the rated life greater optical and performance properties use of light emitting diodes (LEDs) to generate the light. Although LEDs have been commercially available since the late 1960Â’s, recent dramatic improvements in LED technology have led to white light devices with efficiencies that meet or exceed those of a standard incandescent lamp. This project will build upon these improvements to develop a new type of source for focusing light. Contact Information For more information on this project, please contact:

154

Lamp method and apparatus using multiple reflections  

DOE Patents (OSTI)

A method wherein the light in a sulfur or selenium lamp is reflected through the fill a multiplicity of times to convert ultraviolet radiation to visible is disclosed. A light emitting device comprised of an electrodeless envelope which bears a light reflecting covering around a first portion which does not crack due to differential thermal expansion and which has a second portion which comprises a light transmissive aperture. 20 figs.

MacLennan, D.A.; Turner, B.; Kipling, K.

1999-05-11T23:59:59.000Z

155

Lamp method and apparatus using multiple reflections  

DOE Patents (OSTI)

A method wherein the light in a sulfur or selenium lamp is reflected through the fill a multiplicity of times to convert ultraviolet radiation to visible. A light emitting device comprised of an electrodeless envelope which bears a light reflecting covering around a first portion which does not crack due to differential thermal expansion and which has a second portion which comprises a light transmissive aperture.

MacLennan, Donald A. (Butler, PA); Turner, Brian (Damascus, MD); Kipling, Kent (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

156

High output lamp with high brightness  

DOE Patents (OSTI)

An ultra bright, low wattage inductively coupled electrodeless aperture lamp is powered by a solid state RF source in the range of several tens to several hundreds of watts at various frequencies in the range of 400 to 900 MHz. Numerous novel lamp circuits and components are disclosed including a wedding ring shaped coil having one axial and one radial lead, a high accuracy capacitor stack, a high thermal conductivity aperture cup and various other aperture bulb configurations, a coaxial capacitor arrangement, and an integrated coil and capacitor assembly. Numerous novel RF circuits are also disclosed including a high power oscillator circuit with reduced complexity resonant pole configuration, parallel RF power FET transistors with soft gate switching, a continuously variable frequency tuning circuit, a six port directional coupler, an impedance switching RF source, and an RF source with controlled frequency-load characteristics. Numerous novel RF control methods are disclosed including controlled adjustment of the operating frequency to find a resonant frequency and reduce reflected RF power, controlled switching of an impedance switched lamp system, active power control and active gate bias control.

Kirkpatrick, Douglas A. (Great Falls, VA); Bass, Gary K. (Mt. Airy, MD); Copsey, Jesse F. (Germantown, MD); Garber, Jr., William E. (Poolesville, MD); Kwong, Vincent H. (Vancouver, CA); Levin, Izrail (Silver Spring, MD); MacLennan, Donald A. (Gaithersburg, MD); Roy, Robert J. (Frederick, MD); Steiner, Paul E. (Olney, MD); Tsai, Peter (Olney, MD); Turner, Brian P. (Damascus, MD)

2002-01-01T23:59:59.000Z

157

Stress Testing of the Philips 60W Replacement Lamp L Prize Entry  

SciTech Connect

The Pacific Northwest National Laboratory, operated by Battelle for the U.S. Department of Energy, worked with Intertek to develop a procedure for stress testing medium screw-base light sources. This procedure, composed of alternating stress cycles and performance evaluation, was used to qualitatively compare and contrast the durability and reliability of the Philips 60W replacement lamp L Prize entry with market-proven compact fluorescent lamps (CFLs) with comparable light output and functionality. The stress cycles applied simultaneous combinations of electrical, thermal, vibration, and humidity stresses of increasing magnitude. Performance evaluations measured relative illuminance, x chromaticity and y chromaticity shifts after each stress cycle. The Philips L Prize entry lamps appear to be appreciably more durable than the incumbent energy-efficient technology, as represented by the evaluated CFLs, and with respect to the applied stresses. Through the course of testing, all 15 CFL samples permanently ceased to function as a result of the applied stresses, while only 1 Philips L Prize entry lamp exhibited a failure, the nature of which was minor, non-destructive, and a consequence of a known (and resolved) subcontractor issue. Given that current CFL technology appears to be moderately mature and no Philips L Prize entry failures could be produced within the stress envelope causing 100 percent failure of the benchmark CFLs, it seems that, in this particular implementation, light-emitting diode (LED) technology would be much more durable in the field than current CFL technology. However, the Philips L Prize entry lamps used for testing were carefully designed and built for the competition, while the benchmark CFLs were mass produced for retail sale—a distinction that should be taken into consideration. Further reliability testing on final production samples would be necessary to judge the extent to which the results of this analysis apply to production versions of the Philips L Prize entry.

Poplawski, Michael E.; Ledbetter, Marc R.; Smith, Mark

2012-04-24T23:59:59.000Z

158

High intensity discharge lamp self-adjusting ballast system sensitive to the radiant energy or heat of the lamp  

SciTech Connect

This patent describes a self-adjusting ballast system for mercury vapor, high intensity discharge lamps having outputs of 100 watts or greater, comprising: a direct current source; a lamp circuit containing a high intensity discharge lamp; sensing means for sensing the radiant energy output of the lamp; a pulse width modulator which, in response to the output of the sensing means, varies the width of the pulses that power the lamp during warm-up of the lamp; a high frequency oscillator; a DC to AC converter that converts current from the direct source to pulses of alternating current for powering the lamp, the converter comprising: at least one switch for gating current to the lamp; a switch control means, responsive to the high frequency oscillator, for controlling the switch and controlling the frequency of the alternating current pulses that power the lamp; current sensing means for sensing the current being supplied to the lamp; and current control means for limiting the current through the lamp to a predetermined safe level when the current sensed by the current sensing means exceeds a reference value.

Kuhnel, D.S.; Ottenstein, S.A.

1987-07-21T23:59:59.000Z

159

Stay Cool for Less Money with a Ceiling Fan | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Stay Cool for Less Money with a Ceiling Fan Stay Cool for Less Money with a Ceiling Fan Stay Cool for Less Money with a Ceiling Fan May 12, 2009 - 5:00am Addthis Allison Casey Senior Communicator, NREL After a few late snowstorms here in Colorado, I am more than ready to turn off the heat and enjoy some warm spring weather. We haven't had any heat waves here yet, but many of you have already been trying to stay cool; our friends in Washington, D.C. were sweltering (by comparison) in 90+°F weather just a couple short weeks ago! Whether you're still anticipating snow or have broken out the sandals and tank tops, you may be starting to think about keeping your summer cooling costs down. One easy way to keep cool while saving money is using a ceiling fan. Did you know that a ceiling fan could allow you to raise the thermostat

160

Hybrid electronic ballast operating the HPS lamp at constant power  

SciTech Connect

A hybrid solid-state ballast that operates high-pressure sodium (HPS) lamps at main frequency with constant power through rated life is described. The system utilizes two inductors connected in series and a bidirectional semiconductor switch connected in parallel to one of them. A lamp-starting circuit has also been included in the ballast. The static switch, with phase angle control provided by power feedback, actuates on lamp current compensating variations of the main voltage and increases of lamp arc voltage. The system offers the following: (1) increase of lamp life and system lumen maintenance; (2) power factor and total harmonic distortion of line current comparable to conventional lag ballast; and (3) operating cost savings, both in terms of energy cost and lamp replacement cost.

Kaiser, W. [Univ. de Sao Paulo (Brazil)

1998-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Compact microwave lamp having a tuning block and a dielectric located in a lamp cavity  

DOE Patents (OSTI)

A microwave lamp having a compact structure utilizing a coupling slot which has a dielectric member extending therethrough and a tuning block adjoining the coupling slot. A non-conventional waveguide is used which has about the width of a WR-284 waveguide and about the length of a WR-340 waveguide.

Simpson, James E. (Gaithersburg, MD)

2000-01-01T23:59:59.000Z

162

LED LAMP OR BULB WITH REMOTE PHOSPHOR AND DIFFUSER ...  

An LED lamp or bulb is disclosed that comprises a light source, a heat sink structure and an optical cavity. The optical cavity comprises a phosphor ...

163

Development and characterization of a high CRI LED lamp.  

E-Print Network (OSTI)

??The aim of this thesis is to realize a high CRI LED lamp using the color mixing technique. We start from a high efficiency white… (more)

Meneghesso , Matteo

2012-01-01T23:59:59.000Z

164

Stadiums and arenas use efficient, high wattage lamps - Today ...  

U.S. Energy Information Administration (EIA)

Other lighting types, such as light-emitting diode (LED), incandescent, and halogen lamps, are used in applications like signals, signage, ...

165

Integrated-circuit control for two-lamp electronic ballast. Final report  

SciTech Connect

Circuitry is described for a solid-state, high-frequency fluorescent ballast designed to operate two F40 T-12 rapid-start lamps. The circuits are designed to be produced by hybrid integrated circuit (IC) technology. The signal components are produced on a single IC chip; the power transistors are attached to an alumina substrate. The initial IC version reduces the component count by about 50%. The cost of each IC in 500K lots is $0.70, replacing discrete parts costing $2.25. Additional savings of more than $1.00 per unit are realized by the decreased assembly time and improved reliability of the ICs. The system performance (two-lamp F40) was compared to the discrete version of the ballast and to an efficient core-coil ballast and found to be 6% less and 20% more efficient, respectively. The decrease in efficiency relative to the discrete version of the ballast is due to retaining some power to the filaments during operation in order to maintain normal lamp life.

Kohler, T.P.

1982-11-01T23:59:59.000Z

166

Estimation of Channel Impulse Response Using Modified Ceiling Bounce Model in Non-Directed Indoor Optical Wireless Systems  

Science Conference Proceedings (OSTI)

In this paper a modification to the traditional Ceiling bounce model is proposed for use with non-directed indoor optical wireless systems which takes into account the transceiver separation distances as well as their actual positions while computing ... Keywords: Diffuse indoor optical systems, Indoor channel impulse response, Modified Ceiling bounce model

K. Smitha; Arumugam Sivabalan; Joseph John

2008-04-01T23:59:59.000Z

167

An Electrical Cathode Model of a High Pressure Sodium Lamp  

Science Conference Proceedings (OSTI)

An electrical cathode model (ECM) of a high pressure sodium lamp (HPS) based on physical laws has been developed. The proposed ECM calculates the instantaneous voltage drop in a cathode sheath and the temperature distribution inside the cathode using ... Keywords: cathode model, HPS lamp ballast designs

Jose Luis Tapia; Joel O. Pacheco Sotelo; Eduardo Diaz Rodriguez; Yulia Nikolaevna Ledeneva; Rene Arnulfo Garcia Hernandez

2010-09-01T23:59:59.000Z

168

DEFINING THE EFFECTIVENESS OF UV LAMPS  

Office of Scientific and Technical Information (OSTI)

ARTI-21CR/610-40030-01 ARTI-21CR/610-40030-01 DEFINING THE EFFECTIVENESS OF UV LAMPS INSTALLED IN CIRCULATING AIR DUCTWORK Final Report Date Published - November 2002 Douglas VanOsdell and Karin Foarde RTI P.O. Box 12194 Research Triangle Park, NC 27709-2194 Prepared for the AIR-CONDITIONING AND REFRIGERATION TECHNOLOGY INSTITUTE 4100 N. Fairfax Drive, Suite 200, Arlington, Virginia 22203 Distribution A - Approved for public release; further dissemination unlimited. DISCLAIMER This report was prepared as an account of work sponsored by the Air-Conditioning and Refrigeration Technology Institute (ARTI) under its "HVAC&R Research for the 21 st Century" (21-CR) program. Neither ARTI, the financial supporters of the 21-CR program, or any agency

169

Contrast between the vertical and horizontal mercury discharge lamps  

SciTech Connect

This paper discusses the thermal behavior of a high pressure mercury lamp in a horizontal position, compared with that of a vertical lamp. The model adopted is three-dimensional, steady, and powered DC. After the model validation, we analyzed temperature fields and velocities for the case of the lamp in a horizontal position by comparing it with those of a lamp in vertical position. This setting initially fixed the wall temperature equal to 1000 K. However, the morphology of the temperature profile in the case of the horizontal lamp indicates that the temperature of the wall cannot be uniform. Thus, we have, in a second time, performed an energy balance at the wall to calculate its temperature. This aims to understand the influence of convection on the thermal properties of the source.

Ben Hamida, M. B.; Helali, H.; Araoud, Z.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, 5019 route de Kairouan Monastir (Tunisia)

2011-06-15T23:59:59.000Z

170

CFD Simulation and Analysis of the Combined Evaporative Cooling and Radiant Ceiling Air-conditioning System  

E-Print Network (OSTI)

Due to such disadvantages as large air duct and high energy consumption of the current all- outdoor air evaporative cooling systems used in the dry region of Northwest China, as well as the superiority of the ceiling cooling system in improving thermal comfort and saving energy, a combined system is presented in this paper. It combines an evaporative cooling system with ceiling cooling, in which the evaporative cooling system handles the entire latent load and one part of the sensible loads, and the ceiling cooling system deals with the other part of sensible loads in the air-conditioned zone, so that the condensation on radiant panels and the insufficiency of cooling capacity can be avoided. The cooling water at 18? used in the cooling coils of ceiling cooling system can be ground water, tap water or the cooled water from cooling towers in the summer. This new air-conditioning system and existing all- outdoor air evaporative cooling system are applied to a project in the city of Lanzhou. Energy consumption analysis of the building is carried out using the energy consumption code. Velocity and temperature distribution in the air-conditioned zone is computed using CFD. According to the results, the energy consumption and indoor human thermal comfort of both systems are then compared. It is concluded that the new system occupies less building space, reduces energy consumption, improves indoor human thermal comfort and saves initial investment.

Xiang, H.; Yinming, L.; Junmei, W.

2006-01-01T23:59:59.000Z

171

Polaris: getting accurate indoor orientations for mobile devices using ubiquitous visual patterns on ceilings  

Science Conference Proceedings (OSTI)

Ubiquitous computing applications commonly use digital compass sensors to obtain orientation of a device relative to the magnetic north of the earth. However, these compass readings are always prone to significant errors in indoor environments due to ... Keywords: ceiling pictures, digital compass, orientation

Zheng Sun; Aveek Purohit; Shijia Pan; Frank Mokaya; Raja Bose; Pei Zhang

2012-02-01T23:59:59.000Z

172

Numerical studies on the transient behaviour of a fire plume and ceiling jet  

Science Conference Proceedings (OSTI)

Transient behaviour of a thermally induced fire plume and ceiling jet is predicted using the field modelling technique. In the field model, the k-@e model is used to simulate the turbulent air flow. The traditional wall-function approach is applied to ...

W.K Chow

1993-05-01T23:59:59.000Z

173

Energy efficient fluorescent ballasts. Phase I, final report  

SciTech Connect

The development of a high-frequency electronic (Stevens) ballast for fluorescent lamps is described. It is claimed that use of this ballast could reduce use energy consumption by 1.2 to 2.5 percent. The Stevens ballast has a basic efficiency of 29 percent when used with conventional lamps. With the more efficient lamps, the efficiency increases drastically. The conventional ballast and lamp has an efficiacy of approximately 60 to 63 lumens per watt (LPW). With the Stevens ballast the efficiacy raises to between 75 and 80 lumens per watt. When the Stevens ballast is utilized with the newer high efficiency lamps the efficiacy increases to 90 to 95 lumens per watt or a full 51 percent improvement over conventional coil and core ballasts and 25 percent over the best high efficiency premium coil and core ballasts. In addition to its energy savings capabilities, this high frequency fluorescent lamp ballast has the advantages that it is a true retrofit device that is directly interchangeable with the conventional coil core ballast, and it is dimmable over a wide and continuous range. (LCLC)

Stevens Luminoptics Corporation

1978-06-21T23:59:59.000Z

174

Highly Efficient Small Form Factor LED Retrofit Lamp  

SciTech Connect

This report summarizes work to develop a high efficiency LED-based MR16 lamp downlight at OSRAM SYLVANIA under US Department of Energy contract DE-EE0000611. A new multichip LED package, electronic driver, and reflector optic were developed for these lamps. At steady-state, the lamp luminous flux was 409 lumens (lm), luminous efficacy of 87 lumens per watt (LPW), CRI (Ra) of 87, and R9 of 85 at a correlated color temperature (CCT) of 3285K. The LED alone achieved 120 lumens per watt efficacy and 600 lumen flux output at 25 C. The driver had 90% electrical conversion efficiency while maintaining excellent power quality with power factor >0.90 at a power of only 5 watts. Compared to similar existing MR16 lamps using LED sources, these lamps had much higher efficacy and color quality. The objective of this work was to demonstrate a LED-based MR16 retrofit lamp for replacement of 35W halogen MR16 lamps having (1) luminous flux of 500 lumens, (2) luminous efficacy of 100 lumens per watt, (3) beam angle less than 40{sup o} and center beam candlepower of at least 1000 candelas, and (4) excellent color quality.

Steven Allen; Fred Palmer; Ming Li

2011-09-11T23:59:59.000Z

175

Lamp method and apparatus using multiple reflections  

DOE Patents (OSTI)

An electrodeless microwave discharge lamp includes an envelope with a discharge forming fill disposed therein which emits light, the fill being capable of absorbing light at one wavelength and re-emitting the absorbed light at a different wavelength, the light emitted from the fill having a first spectral power distribution in the absence of reflection of light back into the fill, a source of microwave energy coupled to the fill to excite the fill and cause the fill to emit light, and a reflector disposed within the microwave cavity and configured to reflect at least some of the light emitted by the fill back into the fill while allowing some light to exit, the exiting light having a second spectral power distribution with proportionately more light in the visible region as compared to the first spectral power distribution, wherein the light re-emitted by the fill is shifted in wavelength with respect to the absorbed light and the magnitude of the shift is in relation to an effective optical path length.

MacLennan, Donald A. (Gaithersburg, MD); Turner, Brian P. (Damascus, MD)

2001-01-01T23:59:59.000Z

176

Max Tech and Beyond: High-Intensity Discharge Lamps  

E-Print Network (OSTI)

the reason industry started by developing ceramic MH lampsceramic metal halide lamps, which are the focus of industry’industry had invested in the development of very low wattage ceramic

Scholand, Michael

2012-01-01T23:59:59.000Z

177

The LAMP QPF Products. Part I: Model Development  

Science Conference Proceedings (OSTI)

The Local AWIPS (Advanced Weather Interactive Processing System) MOS (model output statistics) Program (LAMP) quantitative precipitation forecast (QPF) system produces 1–22-h forecasts of precipitation over the conterminous United States. The ...

Jerome P. Charba

1998-12-01T23:59:59.000Z

178

One piece microwave container screens for electrodeless lamps  

DOE Patents (OSTI)

A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. Replacing mesh material by solid metal material as part of the screen unit significantly reduces leakage of microwave energy from the lamp. The solid section has multiple compliant fingers defined therein for engaging the periphery of a flange on the waveguide unit so that a hose clamp can easily secure the screen to the assembly. Screen units of this type having different mesh section configurations can be interchanged in the lamp assembly to produce different respective illumination patterns.

Turner, Brian (Myersville, MD); Ury, Michael (Bethesda, MD)

1998-01-01T23:59:59.000Z

179

An ultraviolet barrier-discharge OH molecular lamp  

Science Conference Proceedings (OSTI)

The energy and spectral parameters of a barrier discharge in a mixture of argon with hydroxyl {sup .}OH are studied experimentally. A sealed lamp with the radiation intensity maximum at {lambda} = 309.2 nm, an emitting surface area of {approx}700 cm{sup 2}, and a radiant excitance of 1.5 mW cm{sup -2} has been fabricated. The radiant power of the lamp is 1.1 W. (laser applications and other topics in quantum electronics)

Sosnin, E A; Erofeev, M V; Avdeev, S M; Panchenko, Aleksei N; Panarin, V A; Skakun, V S; Tarasenko, Viktor F; Shitts, D V [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk (Russian Federation)

2006-10-31T23:59:59.000Z

180

New and Underutilized Technology: Efficient High Bay Fluorescent Lighting |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Efficient High Bay Fluorescent Efficient High Bay Fluorescent Lighting New and Underutilized Technology: Efficient High Bay Fluorescent Lighting October 7, 2013 - 8:54am Addthis The following information outlines key deployment considerations for efficient high bay fluorescent lighting within the Federal sector. Benefits Efficient high bay fluorescent lighting can include either T5 or T8 fluorescent lighting systems for high-bay applications currently using metal halide fixtures. Fluorescent fixtures offer better light distribution, better light maintenance over the life of the lamp, improved color quality, and on-off control (re-strike time) with lower energy consumption. Application Efficient high bay fluorescent lighting is applicable for facilities containing high bay areas. Key Factors for Deployment

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Nonhydrostatic, Mesobeta-Scale Model Simulations of Cloud Ceiling and Visibility for an East Coast Winter Precipitation Event  

Science Conference Proceedings (OSTI)

Experiments are described that provide an example of the baseline skill level for the numerical prediction of cloud ceiling and visibility, where application to aviation-system safety and efficiency is emphasized. Model simulations of a light, ...

Mark T. Stoelinga; Thomas T. Warner

1999-04-01T23:59:59.000Z

182

Studies on Temperature Dependence of Rubidium Lamp for Atomic Frequency Standard  

Science Conference Proceedings (OSTI)

Rb lamp is a very critical component of the Rb atomic clock's Physics Package. The Rb lamp's performance is very sensitive to temperature and its stability. In this paper we discuss the behaviors of Rb Lamp with temperature. The Rb lamp exciter power and temperature of Rb bulb are very important parameters in controlling the performance of the Rb Lamp. It is observed that at temperatures beyond 110 deg. C, the lamp mode changes from the ring to red mode resulting in abnormal broadening of emission lines and self reversal. The results of our studies on spectral analysis of Rb lamp under various operating conditions are reported in the paper.

Ghosal, Bikash; Banik, Alak; Vats, Vaibhav; Pal, Sukamal; Bahl, R. K [Space Applications Centre, ISRO, Ahmedabad-380015 (India)

2011-10-20T23:59:59.000Z

183

Very high efficacy electrodeless high intensity discharge lamps  

DOE Patents (OSTI)

An electrodeless arc lamp comprises an outer jacket hermetically sealing and thermally protecting an arc tube inside which has an upwardly convex bottom center section. The absence of chemically reactive electrode material makes it possible to use metal halides other than iodides. The tube contains chlorides, bromides or a mixture thereof of scandium and sodium in a nearly equimolar relationship in addition to mercury and an inert gas. Good color balance can be obtained at reduced reservoir temperature and with less power loss. Reduction in wall temperature makes it possible to attain longer lamp life.

Johnson, P.D.

1985-10-03T23:59:59.000Z

184

Hot Air Stratification of Ceiling Air Supply in a Large Space Building  

E-Print Network (OSTI)

The effects of different states of air supply and airflow patterns on temperature gradient distribution are calculated and analyzed with the help of FFSV3.0 software, using the LB models and LES and RANS methods. An experimental study with upper supply and upper return air flow was performed in normal airflow room. The results were compared with numerical simulation results and were found to agree well. Information on delaminating laws, and measurements of the relationship of delaminating heights and air supply temperature and velocity is also presented. According to the simulation results, a formula that avoids hot air delaminating in ceiling air supply is derived, which can guide engineering design.

Wang, H.; Wang, Z.; Liu, C.

2006-01-01T23:59:59.000Z

185

Flow and heat transfer due to a buoyant ceiling jet turning downward at a corner  

Science Conference Proceedings (OSTI)

An experimental investigation has been carried out on the flow and heat transfer characteristics of a horizontal buoyant ceiling jet that turns downward at a corner to yield a vertical negatively buoyant wall flow. In this study, a two-dimensional jet of heated air is discharged adjacent to the lower surface of an isothermal horizontal plate. An isothermal vertical plate is attached at the other end of the horizontal surface, making a right angle corner. The vertical penetration distance of the resulting downward flow is measured and is related to the inflow conditions, particularly to the temperature and velocity at the jet discharge. This penetration distance is found to increase as the distance between the discharge location and the corner is reduced and also as the relative buoyancy level in the inlet flow is decreased. Velocity and temperature measurements are also carried out over the flow region. These indicate that the ceiling flow separates from the horizontal surface just before reaching the corner and then reattaches itself to the vertical wall at a finite distance vertically below the corner. The local surface heat flux measurements show a minimum in the heat transfer rate before the turn, along with a recovery in the heat transfer rate after the turn and the existence of a small recirculation zone near the corner. The net entrainment into the flow and heat transfer rate to the solid boundaries are also measured and correlated with the jet discharge conditions. 22 refs., 12 figs., 1 tab.

Kapoor, K.; Jaluria, Y. [Rutgers - State Univ. of New Jersey, New Brunswick, NJ (United States)

1996-02-01T23:59:59.000Z

186

Solid-State Lighting: LED Replacement Lamps: Current Performance and the  

NLE Websites -- All DOE Office Websites (Extended Search)

LED Replacement Lamps: Current LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® to someone by E-mail Share Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Facebook Tweet about Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Twitter Bookmark Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Google Bookmark Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Delicious Rank Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on Digg Find More places to share Solid-State Lighting: LED Replacement Lamps: Current Performance and the Latest on ENERGY STAR® on

187

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

E-Print Network (OSTI)

the economics of fuel-based and LED lighting technology fordata logger equipped rechargeable LED lamps, monitoring theadoption of the LED lamps, and a follow-up survey. 1 Figure

Johnstone, Peter

2009-01-01T23:59:59.000Z

188

Sustainable LED Fluorescent Light Replacement Technology  

SciTech Connect

Ilumisys and the National Center for Manufacturing Sciences (NCMS) partnered on a three-year project awarded by the United States (U.S.) Department of Energy (DOE), to quantify the impacts of LED lamps, incandescent lamps and fluorescent benchmark lamps over a product lifecycle – i.e. to develop a sustainable design and manufacturing strategy that addresses product manufacturing, use, recycling and disposal scenarios for LED-based lighting. Based on the knowledge gained from extensive product tear-down studies of fluorescent and screw-in lighting products, lifecycle assessment tools, and accelerated lifecycle testing protocols, an interactive Sustainable LED Design Guide has been developed to aid architectural and lighting designers and engineers in making design decisions that consider three important environmental impacts (greenhouse gas emissions, energy use and mercury emission) across all phases of the life of an LED lighting product. Critical information developed for the lifecycle analysis and product feature comparisons is the useful life of the lighting product as well as its performance. The Design Guide is available at www.ncms.org, and was developed based on operational and durability testing of a variety of lighting products including power consumption, light output, and useful life of a lamp in order to allow a more realistic comparison of lamp designs. This report describes the main project tasks, results and innovative features of the lifecycle assessment (LCA)-based design tools, and the key considerations driving the sustainable design of LED lighting systems. The Design Guide incorporates the following three novel features for efficiently evaluating LED lighting features in value-chains: • Bill-of-Materials (BOM) Builder – Designers may import process data for each component and supply functional data for the product, including power, consumption, lumen output and expected useful life. • Environmental Impact Review – Designs are comparable across lifecycle phases, subsystems, and environmental impact category, and can be normalized to a userdefined functional unit. • Drill-down Review – These provide an indepth look at individual lamp designs with the ability to review across subsystem or lifecycle phase.

None

2011-06-30T23:59:59.000Z

189

Inrush related problems caused by lamps with electronic drivers and their mitigation  

Science Conference Proceedings (OSTI)

New types of appliances sometimes bring unexpected power quality problems. On several locations it was reported that energy-saving lamps cause random false tripping of circuit breakers. In all of these cases these lamps had electronic drivers. An investigation ... Keywords: energy-saving lamp, false tripping, inrush, mitigation, power quality

Vladimir ?uk; Joseph F. G. Cobben; Wil L. Kling

2011-07-01T23:59:59.000Z

190

Visualization of heat transport using dimensionless heatfunction for natural convection and conduction in an enclosure with thick solid ceiling  

Science Conference Proceedings (OSTI)

A conjugate conduction-(natural)convection problem is numerically studied in order to present the application of dimensionless heatfunction for entire computational domain including solid and fluid regions in an enclosure with thick solid ceiling. The ... Keywords: Conjugate heat transfer, Dimensionless heatfunction, Heat transport, Heatline, Natural convection

Moghtada Mobedi; Hakan F. Oztop

2008-11-01T23:59:59.000Z

191

Sulfur Lamps-The Next Generation of Efficient Light?  

NLE Websites -- All DOE Office Websites (Extended Search)

5 5 Sulfur Lamps-The Next Generation of Efficient Light? The figure above is a schematic of the system installed at the National Air and Space Museum and the DOE headquarters in Washington, D.C., Light from the sulfur lamp is focused by a parabolic reflector so that it enters the light pipe within a small angular cone. Light travels down the pipe, reflecting off the prismatic film (A) that lines the outer acrylic tube. The prismatic film reflects the light through total internal reflection (C), an intrinsically efficient process. Some of the light striking the film (at A) is not reflected and "leaks out" of the pipe walls (B), giving the pipe a glowing appearance. A light ray that travels all the way down the pipe will strike the mirror at the end (D) and return back up the pipe.

192

L Prize Competition Winner 60W Incandesent Replacement Lamp Update  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Technology Deployment Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International May 23, 2012 Philips Wins First L Prize 2 * August 3, 2011: Philips announced as winner of 60W replacement bulb category * Product distributed thru commercial and retail channels Image courtesy of Philips -...[O]nce an award is made the authorizing Act directs General Services Administration to develop federal purchasing schedules for solid-state lamps that meet or exceed the specifications laid out in the prize category-so long as it is cost effective. I hope the GSA begins this process soon.‖

193

A light diet for a giant appetite: An assessment of China's proposed fluorescent lamp standard  

E-Print Network (OSTI)

Green Lights Program to promote efficient lighting products through public education, consumer incentives, national product testing, and investments

Lin, Jiang

2002-01-01T23:59:59.000Z

194

The Energy Efficiency of the U.S Fluorescent Lamp Ballast Industry  

NLE Websites -- All DOE Office Websites (Extended Search)

News Latest News Videos Community Relations Past Projects Rebuilding Together Energy Teams Events Past Events For The Media Seminars Past Seminars Speakers Distinguished...

195

Phase II report on energy efficient electronic ballasts for a two-40 watt fluorescent lamp system  

SciTech Connect

The Department of Energy (DOE) has established a project aimed at accelerating the commercialization of electronic ballasts. During the Phase I portion of the project a small quantity of ballasts and other hardware were delivered for independent testing. Results verified the claims for energy savings and other unique and advantageous features of the electronic ballast. Phase II, a large scale field demonstration, is reported. The demonstration is being conducted by LBL and the Pacific Gas and Electric Company in the PG and E headquarters building in downtown San Fracisco. The test demonstration hardware is being procured. Included are two models of energy saving ballasts; two dimmer systems that show the potential for additional power savings; and, two models of Automatic Emergency Light Systems. Installation of ballasts and the beginning of actual test operations were originally scheduled for February 1978. However, slippages in hardware deliveries have caused a three-month delay. Testing at PG and E is now scheduled to begin in June 1978. Even though broad scale results from the Phase II demonstration at PG and E are not yet available, performance and versatility advantages of the electronic ballast have been demonstrated. They offer a clear incentive to the industry for development and production of reliable hardware that will be competitively saleable on a long term cost-of-lighting basis.

1978-07-01T23:59:59.000Z

196

A dimmable (1000:1 range) fluorescent ballast for instrument panel lighting  

SciTech Connect

A 1000:1 wide range continuously dimmable ballast is designed for fluorescent lighting of aircraft instrument panels. High voltage, low energy, 800 Hz starting pulses reliably start the lamps at all light level settings. The starting pulses alone produce the illumination at the minimum light control setting.

Lauritzen, P.O.; Jorgensen, J.A.; Meyer, S.D.; Osborn, J.G.

1983-01-01T23:59:59.000Z

197

Fluorescent refrigeration  

DOE Patents (OSTI)

Fluorescent refrigeration is based on selective radiative pumping, using substantially monochromatic radiation, of quantum excitations which are then endothermically redistributed to higher energies. Ultimately, the populated energy levels radiatively deexcite emitting, on the average, more radiant energy than was initially absorbed. The material utilized to accomplish the cooling must have dimensions such that the exciting radiation is strongly absorbed, but the fluorescence may exit the material through a significantly smaller optical pathlength. Optical fibers and mirrored glasses and crystals provide this requirement. 6 figs.

Epstein, R.I.; Edwards, B.C.; Buchwald, M.I.; Gosnell, T.R.

1995-09-05T23:59:59.000Z

198

Microwave lamp with multi-purpose rotary motor  

DOE Patents (OSTI)

In a microwave powered electrodeless lamp, a single rotary motor is used to (a) rotate the bulb and (b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooler for providing cooling gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement. 8 figs.

Ury, M.G.; Turner, B.; Wooten, R.D.

1999-02-02T23:59:59.000Z

199

Microwave lamp with multi-purpose rotary motor  

DOE Patents (OSTI)

In a microwave powered electrodeless lamp, a single rotary motor is used to a) rotate the bulb and b) provide rotary motion to a blower or pump means for providing cooling fluid to the magnetron and/or to a forced gas cooling for providing cooler gas to the bulb. The blower may consist of only of an impeller without the usual blower housing. The motor, bulb stem and bulb, or motor, bulb stem, bulb and blower may be formed as an integral unit so as to facilitate replacement.

Ury, Michael G. (Bethesda, MD); Turner, Brian (Myersville, MD); Wooten, Robert D. (Rockville, MD)

1999-01-01T23:59:59.000Z

200

Low pressure arc discharge lamp apparatus with magnetic field generating means  

DOE Patents (OSTI)

A low-pressure arc discharge apparatus having a magnetic field generating means for increasing the output of a discharge lamp is disclosed. The magnetic field generating means, which in one embodiment includes a plurality of permanent magnets, is disposed along the lamp for applying a constant transverse magnetic field over at least a portion of the positive discharge column produced in the arc discharge lamp operating at an ambient temperature greater than about 25 C. 3 figs.

Grossman, M.W.; George, W.A.; Maya, J.

1987-10-06T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

E-Print Network (OSTI)

for Small Businesses in Kenya." Lumina Project Technicalfor Night Market Vendors in Kenya who use LED Lamps Petermany people and businesses in Kenya who participated in this

Johnstone, Peter

2009-01-01T23:59:59.000Z

202

Guidance Concerning Enforcement of EISA 2007 Standards Candelabra Base and Intermediate Base Lamps  

Energy.gov (U.S. Department of Energy (DOE))

The Energy Independence and Security Act of 2007 (EISA 2007) imposed energy conservation standards for candelabra and intermediate base lamps, and those provisions became effective with the statute.

203

Demonstration of LED Retrofit Lamps at the Smithsonian American Art Museum, Washington, DC  

Science Conference Proceedings (OSTI)

This report documents observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy GATEWAY Solid-State Lighting (SSL) Technology Demonstration Program at the Smithsonain American Art Museum in Washington, DC. LED Lamp samples were tested in the museum workshop, temporarily installed in a gallery for feedback, and ultimately replaced all traditional incandescent lamps in one gallery of modernist art at the American Art Museum and partially replacing lamps in two galleries at the Musesum's Renwick Gallery. This report describes the selection and testing process, technology challenges, perceptions, economics, energy use, and mixed results of usign LED replacement lamps in art galleries housing national treasures.

Miller, Naomi J.; Rosenfeld, Scott M.

2012-06-22T23:59:59.000Z

204

EA-1911: Energy Conservation Standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps  

Energy.gov (U.S. Department of Energy (DOE))

This EA will evaluate the environmental impacts of a proposal to amend energy conservation standards for Certain Reflector, Elliptical Reflector, and Bulged Reflector Incandescent Lamps.

205

Spatial and Microphysical Characteristics of Low-Ceiling, Temperature-Inverted Clouds in Warm Overrunning and Freezing-Rain Conditions: A Case Study  

Science Conference Proceedings (OSTI)

In-flight microphysical measurements in classical freezing-rain conditions were used to study the vertical and horizontal characteristics of the precipitation and associated low-ceiling, stratiform clouds, which are usually present as overcast in ...

Richard K. Jeck

2011-10-01T23:59:59.000Z

206

High Efficiency LED Lamp for Solid-State Lighting  

SciTech Connect

This report contains a summary of technical achievements during a three-year project to demonstrate high efficiency, solid-state lamps based on gallium nitride/silicon carbide light-emitting diodes. Novel chip designs and fabrication processes are described for a new type of nitride light-emitting diode with the potential for very high efficiency. This work resulted in the demonstration of blue light-emitting diodes in the one watt class that achieved up to 495 mW of light output at 350 mA drive current, corresponding to quantum and wall plug efficiencies of 51% and 45%, respectively. When combined with a phosphor in Cree's 7090 XLamp package, these advanced blue-emitting devices resulted in white light-emitting diodes whose efficacy exceeded 85 lumens per watt. In addition, up to 1040 lumens at greater than 85 lumens per watt was achieved by combining multiple devices to make a compact white lamp module with high optical efficiency.

James Ibbetson

2006-12-31T23:59:59.000Z

207

Lighting the Way with Compact Fluorescent Lighting | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lighting the Way with Compact Fluorescent Lighting Lighting the Way with Compact Fluorescent Lighting Lighting the Way with Compact Fluorescent Lighting April 28, 2009 - 5:00am Addthis John Lippert There is a major push today to get homeowners to adopt compact fluorescent lamp (CFL) light bulbs. They have been on the market for nearly three decades, and many homeowners still do not use them widely. But the tide is definitely turning. Their availability and the percentage of homeowners familiar with the technology and purchasing them for their homes have been steadily rising. The products have improved considerably compared to early products, and their prices have plummeted. The ENERGY STAR® Change a Light, Change the World Campaign has been running now for more than half a dozen years. This campaign is designed to

208

Lighting the Way with Compact Fluorescent Lighting | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lighting the Way with Compact Fluorescent Lighting Lighting the Way with Compact Fluorescent Lighting Lighting the Way with Compact Fluorescent Lighting April 28, 2009 - 5:00am Addthis John Lippert There is a major push today to get homeowners to adopt compact fluorescent lamp (CFL) light bulbs. They have been on the market for nearly three decades, and many homeowners still do not use them widely. But the tide is definitely turning. Their availability and the percentage of homeowners familiar with the technology and purchasing them for their homes have been steadily rising. The products have improved considerably compared to early products, and their prices have plummeted. The ENERGY STAR® Change a Light, Change the World Campaign has been running now for more than half a dozen years. This campaign is designed to

209

Compact Fluorescent Plug-In Ballast-in-a-Socket  

Science Conference Proceedings (OSTI)

The primary goal of this program was to develop a ballast system for plug-in CFLs (compact fluorescent lamps) that will directly replace standard metal shell, medium base incandescent lampholders (such as Levition No. 6098) for use with portable lamp fixtures, such as floor, table and desk lamps. A secondary goal was to identify a plug-in CFL that is optimized for use with this ballast. This Plug-in CFL Ballastin-a-Socket system will allow fixture manufacturers to easily manufacture CFL-based high-efficacy portable fixtures that provide residential and commercial consumers with attractive, cost-effective, and energy-efficient fixtures for use wherever portable incandescent fixtures are used today. The advantages of this proposed system over existing CFL solutions are that the fixtures can only be used with high-efficacy CFLs, and they will be more attractive and will have lower life-cycle costs than screw-in or adapter-based CFL retrofit solutions. These features should greatly increase the penetration of CFL's into the North American market. Our work has shown that using integrated circuits it is quite feasible to produce a lamp-fixture ballast of a size comparable to the current Edison-screw 3-way incandescent fixtures. As for price points for BIAS-based fixtures, end-users polled by the Lighting Research Institute at RPI indicated that they would pay as much as an additional $10 for a lamp containing such a ballast. The ballast has been optimized to run with a 26 W amalgam triple biax lamp in the base-down position, yet can accept non-amalgam versions of the lamp. With a few part alterations, the ballast can be produced to support 32 W lamps as well. The ballast uses GE's existing L-Comp[1] power topology in the circuit so that the integrated circuit design would be a design that could possibly be used by other CFL and EFL products with minor modifications. This gives added value by reducing cost and size of not only the BIAS, but also possibly other integral CFL and future dimmable integral and plug-in versions of the EFL products.

Rebecca Voelker

2001-12-21T23:59:59.000Z

210

Spectral irradiance model for tungsten halogen lamps in 340-850 nm wavelength range  

Science Conference Proceedings (OSTI)

We have developed a physical model for the spectral irradiance of 1 kW tungsten halogen incandescent lamps for the wavelength range 340-850 nm. The model consists of the Planck's radiation law, published values for the emissivity of tungsten, and a residual spectral correction function taking into account unknown factors of the lamp. The correction function was determined by measuring the spectra of a 1000 W, quartz-halogen, tungsten coiled filament (FEL) lamp at different temperatures. The new model was tested with lamps of types FEL and 1000 W, 120 V quartz halogen (DXW). Comparisons with measurements of two national standards laboratories indicate that the model can account for the spectral irradiance values of lamps with an agreement better than 1% throughout the spectral region studied. We further demonstrate that the spectral irradiance of a lamp can be predicted with an expanded uncertainty of 2.6% if the color temperature and illuminance values for the lamp are known with expanded uncertainties of 20 K and 2%, respectively. In addition, it is suggested that the spectral irradiance may be derived from resistance measurements of the filament with lamp on and off.

Ojanen, Maija; Kaerhae, Petri; Ikonen, Erkki

2010-02-10T23:59:59.000Z

211

On-site demonstration procedure for solid-state fluorescent ballast  

SciTech Connect

The report was presented to plant engineers and managers who were involved in an on-site demonstration of EETech solid-state ballasts for two 40-watt T12 fluorescent lamps. The report includes a brief review of the operating principles of solid-state fluorescent ballasts and the status of development achieved during the LBL program. The remainder of the test describes the techniques of managing and instrumenting a test area for assessing the performance of solid-state fluorescent ballasts at an occupied site.

Verderber, R.; Morse, O.

1980-09-01T23:59:59.000Z

212

Research on Active Power Factor Correction of the Electronic Ballast for High-Pressure Sodium Lamps Based on L6563  

Science Conference Proceedings (OSTI)

In the recent years, there has been a growing interest in the design of high-pressure sodium lamp electronic ballast. Two measures are proposed to improve the power factor of high-pressure sodium lamp electronic ballasts from the definition of harmonic ... Keywords: high-pressure sodium lamps, electronic ballast, active power factor correction, L6563

Sun Jing

2010-06-01T23:59:59.000Z

213

Lamp system with conditioned water coolant and diffuse reflector of polytetrafluorethylene(PTFE)  

SciTech Connect

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, Luis E. (Livermore, CA); Hackel, Lloyd (Livermore, CA)

1999-01-01T23:59:59.000Z

214

Lamp system with conditioned water coolant and diffuse reflector of polytetrafluorethylene(PTFE)  

SciTech Connect

A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO{sub 2}) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.

Zapata, L.E.; Hackel, L.

1999-10-26T23:59:59.000Z

215

Miniature UV lamp excited by subnanosecond voltage pulses  

SciTech Connect

Energy, time, and spectral characteristics of emission of the second positive system of N{sub 2} molecules in gaseous nitrogen, Ar - N{sub 2} mixture, and air are investigated. An FPG-10 generator with voltage pulse FWHM of 200 and 400 ps and matched-load amplitudes of 14 and 6 kV, respectively, is used to excite gases. It is shown that excitation can be performed in two regimes using this generator. In the first regime a diffuse discharge is formed at atmospheric pressure, which opens ways to design miniature nanosecond UV lamps. A diffuse discharge is formed due to the generation of runaway electrons, with the aid of electrodes having a small radius of curvature and voltage pulses with a sharp leading edge. In the second regime an elevated average radiation power is obtained under excitation by a barrier discharge. However, the operating pressure is lower in this case, and the sizes of the emitting region and the UV pulse width significantly increase. (laser applications and other topics in quantum electronics)

Erofeev, M V; Baksht, E Kh; Tarasenko, Viktor F; Shut'ko, Yu V [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk (Russian Federation)

2010-08-27T23:59:59.000Z

216

On the Brightness of the Thomson Lamp: A Prolegomenon to Quantum Recursion Theory  

Science Conference Proceedings (OSTI)

Some physical aspects related to the limit operations of the Thomson lamp are discussed. Regardless of the formally unbounded and even infinite number of "steps" involved, the physical limit has an operational meaning in agreement with the Abel sums ...

Karl Svozil

2009-09-01T23:59:59.000Z

217

Demonstration of LED Retrofit Lamps at the Jordan Schnitzer Museum of Art  

SciTech Connect

The Jordan Schnitzer Museum of Art in Eugene, Oregon, houses a remarkable permanent collection of Asian art and antiquities, modern art, and sculpture, and also hosts traveling exhibitions. In the winter and spring of 2011, a series of digital photographs by artist Chris Jordan, titled "Running the Numbers," was exhibited in the Coeta and Donald Barker Special Exhibitions Gallery. These works graphically illustrate waste (energy, money, health, consumer objects, etc.) in contemporary culture. The Bonneville Power Administration and the Eugene Water and Electricity Board provided a set of Cree 12W light-emitting diode (LED) PAR38 replacement lamps (Cree LRP38) for the museum to test for accent lighting in lieu of their standard Sylvania 90W PAR38 130V Narrow Flood lamps (which draw 78.9W at 120V). At the same time, the museum tested LED replacement lamps from three other manufacturers, and chose the Cree lamp as the most versatile and most appropriate color product for this exhibit. The lamps were installed for the opening of the show in January 2011. This report describes the process for the demonstration, the energy and economic results, and results of a survey of the museum staff and gallery visitors on four similar clusters of art lighted separately by four PAR38 lamps.

Miller, Naomi J.

2011-09-01T23:59:59.000Z

218

A spreadsheet for analyzing the in situ performance of fluorescent luminaires  

SciTech Connect

A spreadsheet program for determining system efficacy, power input and light output of common 4 ft fluorescent lighting systems under realistic operating conditions is described. The program uses accepted IES engineering principles to precisely account for ballast factor, existing thermal conditions and maintenance practices. The spreadsheet, which includes a data base of lamp and ballast performance data, can be used to calculate the cost-effectiveness of many common lighting retrofits.

Rubinstein, F.; Zhang, Chin

1991-08-01T23:59:59.000Z

219

Skill of a Ceiling and Visibility Local Ensemble Prediction System (LEPS) according to Fog-Type Prediction at Paris-Charles de Gaulle Airport  

Science Conference Proceedings (OSTI)

A specific event, called a low-visibility procedure (LVP), has been defined when visibility is under 600 m and/or the ceiling is under 60 m at Paris-Charles de Gaulle Airport, Paris, France, to ensure air traffic safety and to reduce the economic ...

Stevie Roquelaure; Robert Tardif; Samuel Remy; Thierry Bergot

2009-12-01T23:59:59.000Z

220

Assessment of Electrical, Efficiency, and Photometric Performance of Advanced Lighting Technologies: Dimmable Advanced Lighting Tech nologies -- Electronic Fluorescent, High-Intensity Discharge, and Light-Emitting Diode  

Science Conference Proceedings (OSTI)

This EPRI Technical Report is a compilation of four technical updates that address the basic dimming performance of advanced lighting sources: EPRI report 1018476 for linear fluorescent ballasts, 1018477 for hot and cold cathode compact fluorescent lamps, 1018479 for electronic high-intensity discharge (HID) ballasts, and 1018480 for light-emitting diode (LED) lighting. Chapter 1 provides a discussion of basic lighting control, the importance of considering power quality in lighting control, lighting con...

2008-12-22T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Testing of energy conservation of electronic ballasts for fluorescent lighting. Review of recent results and recommendations for design goals  

SciTech Connect

The performance of two 40-watt T-12 fluorescent lamps driven by both standard core-coil, and electronic ballasts has been measured over a range of temperatures and input voltages that simulate conditions they would experience in typical building installations. When using new energy-efficient lamps and electronic ballasts, an efficiency of 90 lumens/watt has been achieved, which represents an efficiency improvement of over 37% relative to standard lamps and core-coil ballasts. From these results, several design targets are suggested for ballast developers. Additional features of the electronic ballasts, (low noise, no flicker, and light level control), have potential to increase the use of efficient light sources (gas discharge types) as well as permit less costly luminaire construction. The dimming feature should also conserve energy whenever applied.

Verderber, R.R.; Cooper, D.; Ross, D.K.

1978-10-01T23:59:59.000Z

222

Determination of the cathode and anode voltage drops in high power low-pressure amalgam lamps  

Science Conference Proceedings (OSTI)

For the first time, cathode and anode drops of powerful low-pressure amalgam lamps were measured. The lamp discharge current is 3.2 A, discharge current frequency is 43 kHz, linear electric power is 2.4 W/cm. The method of determination of a cathode drop is based on the change of a lamp operating voltage at variation of the electrode filament current at constant discharge current. The total (cathode plus anode) drop of voltage was measured by other, independent ways. The maximum cathode fall is 10.8 V; the anode fall corresponding to the maximal cathode fall is 2.4 V. It is shown that in powerful low pressure amalgam lamps the anode fall makes a considerable contribution (in certain cases, the basic one) to heating of electrodes. Therefore, the anode fall cannot be neglected, at design an electrode and ballast of amalgam lamps with operating discharge current frequency of tens of kHz.

Vasilyak, L. M., E-mail: vasilyak@ihed.ras.ru [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation); Vasiliev, A. I., E-mail: vasiliev@npo.lit.ru; Kostyuchenko, S. V.; Sokolov, D. V.; Startsev, A. Yu. [Joint Stock Company NPO LIT (Russian Federation); Kudryavtsev, N. N. [Moscow Institute of Physics and Technology (State University) (Russian Federation)

2011-12-15T23:59:59.000Z

223

Energy-Efficient, High-Color-Rendering LED Lamps Using Oxyfluoride and Fluoride Phosphors  

Science Conference Proceedings (OSTI)

LED lamps using phosphor downconversion can be designed to replace incandescent or halogen sources with a 'warm-white' correlated color temperature (CCT) of 2700-3200 K and a color rendering index (CRI) greater than 90. However, these lamps have efficacies of {approx}70% of standard 'cool-white' LED packages (CCT = 4500-6000 K; CRI = 75-80). In this report, we describe structural and luminescence properties of fluoride and oxyfluoride phosphors, specifically a (Sr,Ca){sub 3}(Al,Si)O{sub 4}(F,O):Ce{sup 3+} yellow-green phosphor and a K{sub 2}TiF{sub 6}:Mn{sup 4+} red phosphor, that can reduce this gap and therefore meet the spectral and efficiency requirements for high-efficacy LED lighting. LED lamps with a warm-white color temperature (3088 K), high CRI (90), and an efficacy of {approx}82 lm/W are demonstrated using these phosphors. This efficacy is {approx}85% of comparable cool-white lamps using typical Y{sub 3}Al{sub 5}O{sub 12}:Ce{sup 3+}-based phosphors, significantly reducing the efficacy gap between warm-white and cool-white LED lamps that use phosphor downconversion.

Setlur, A.; Radkov, E; Henderson, C; Her, J; Srivastava, A; Karkada, N; Kishore, M; Kumar, N; Aesram, D; et al.

2010-01-01T23:59:59.000Z

224

L-Prize Competition Winner 60W Incandescent Replacement Lamp Update  

NLE Websites -- All DOE Office Websites (Extended Search)

Interagency Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International March 15, 2012 Cost of electricity 1 cent per kilowatt-hour The Washington Post, March 8, 2012 Page One 2 Cost of electricity 11 cents per kilowatt-hour The Washington Post, March 9, 2012 Page Two 3 What Is the L Prize? * Technology competition to spur innovation and exceptional performance * Created by Energy Independence and Security Act (EISA 2007) Sec. 655 * Two key lamp replacements: 60W Incandescent and PAR 38 Halogen * Future focus: 21 st Century Lamp * Cash prizes, federal purchasing, utility programs 4 Philips Wins First L Prize * August 3, 2011: Philips

225

L-Prize Competition Winner 60W Incandescent Replacement Lamp Update  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interagency Technology Deployment Working Group L Prize ® Competition Winner 60W Incandescent Replacement Lamp Update James E. Rannels, Senior Advisor L Prize Competition D&R International March 15, 2012 Cost of electricity 1 cent per kilowatt-hour The Washington Post, March 8, 2012 Page One 2 Cost of electricity 11 cents per kilowatt-hour The Washington Post, March 9, 2012 Page Two 3 What Is the L Prize? * Technology competition to spur innovation and exceptional performance * Created by Energy Independence and Security Act (EISA 2007) Sec. 655 * Two key lamp replacements: 60W Incandescent and PAR 38 Halogen * Future focus: 21 st Century Lamp * Cash prizes, federal purchasing, utility programs 4 Philips Wins First L Prize * August 3, 2011: Philips

226

Magical Mystery Devices or Not: How do LED Lamps and Luminaires Really Measure-Up?  

SciTech Connect

Solid-state lighting products for general lighting applications are now gaining a market presence, and more and more people are asking, “Which of these are ‘good’ products? Do they perform as claimed? How do they compare? Light Emitting Diodes (LEDs) differ from other light sources enough to require new procedures for measuring their performance and comparing to other lighting options, so both manufacturers and buyers are facing a learning curve. The energy-efficiency community has traditionally compared light sources based on system efficacy: rated lamp lumens divided by power into the system. This doesn’t work for LEDs because there are no standard LED “lamp” packages and no lamp ratings, and because LED performance depends heavily on thermal, electrical, and optical design of complete lighting unit or ‘luminaire’. Luminaire efficacy is the preferred metric for LEDs because it measures the net light output from the luminaire divided by power into the system.

Paget, Maria L.; McCullough, Jeffrey J.; Steward, Heidi E.

2008-08-15T23:59:59.000Z

227

Spectral distribution of dimmed HID lamps in a plant growth facility  

SciTech Connect

A commercial dimming ballast system for high intensity discharge (HID) lamps has been tested for use in plant growth chambers. The dimming ballast system can be controlled either manually at the dimming panel or by a d.c. voltage from a programmer or computer. Using the dimming system, photosynthetically active radiation can be continuously varied from about 200 to about 2000 ..mu..E m/sup -2/s/sup -1/. This paper shows the effects of dimming on the spectral intensity (400 to 750 nm) of three types of HID lamps measured individually and in combination to achieve a better spectral mix. The lamps used in this study were 400 w metal halide, mercury vapor and high pressure sodium.

Bingham, G.E.; Coyne, P.I.

1979-05-01T23:59:59.000Z

228

Nature of the effect of the ballast volumes of flash lamps on their emission  

SciTech Connect

The cause of the decrease in laser efficiency during pumping by flash lamps with increased ballast volumes is the unproductive loss of radiation, originating from the ballast volumes, and the associated change in the radiation brightness distribution along the length of the lamp. The increase radiation brightness at the electrodes of the light source is not the result of constriction of the discharge or the luminescence of the electrode plasma erosion, but is due to the slowing down of the plasma flows by the surface of the electrodes and to the slowing down of the ionized gas moving from the ballast volumes when it meets the denser plasma of the discharge zone. The profile of the current lines at the electrodes is established and the frequency of the axial oscillations of the plasma in the lamp is determined.

Basov, Yu.G.; Makarov, V.N.; Narkhova, G.I.

1975-11-01T23:59:59.000Z

229

Fluorescent Optical Position Sensor  

Sandia National Laboratories has created a method and apparatus for measuring the position of an object.  It relies on the attenuation of fluorescence light carried inside a fluorescent optical fiber to determine the position of an object. 

230

High frequency transformerless electronics ballast using double inductor-capacitor resonant power conversion for gas discharge lamps  

SciTech Connect

A novel high frequency LCLC double resonant electronic ballast has been developed for gas discharge lamp applications. The ballast consists of a half-bridge inverter which switches at zero voltage crossing and an LCLC resonant circuit which converts a low ac voltage to a high ac voltage. The LCLC resonant circuit has two LC stages. The first LC stage produces a high voltage before the lamp is ignited. The second LC stage limits lamp current with the circuit inductance after the lamp is ignited. In another embodiment a filament power supply is provided for soft start up and for dimming the lamp. The filament power supply is a secondary of the second resonant inductor. 27 figs.

Lai, J.S.

1995-06-20T23:59:59.000Z

231

15 KJ FLASH LAMP, POWER CONDITIONING UNIT DESIGNED FOR SAFTY, RELIABILITY & MANUFACTURABILITY*  

SciTech Connect

A 15kJoule, Flash Lamp Power Conditioning Unit has been successfully designed, developed, and deployed in the National Ignition Facility (NIF) Preamplifier Modules (PAM). The primary design philosophy of this power conditioning unit (PCU) is safety, reliability, and manufacturability. Cost reduction over commercially equivalent systems was also achieved through an easily manufactured packaging design optimized to meet NIF requirements. While still maintaining low cost, the PCU design includes a robust control system, fault diagnostic system, and safety features. The pulsed power design includes 6 PFN modules, each including a dual series injection trigger transformer, that drive a total of 12 flash lamp loads. The lamps are individually triggered via a 20kV pulse produced by a 1kV, MCT switched capacitive discharge unit on the primary side of the trigger transformer. The remote control interface includes an embedded controller that captures flash lamp current wave forms and fault status for each shot. The embedded controller provides the flexibility of remotely adjusting both the main drive voltage from 1.6 to 2.5 kV and the trigger voltage from 0 to 20 kV.

James, G; Merritt, B; Dreifuerst, G; Strickland, S

2007-08-07T23:59:59.000Z

232

A Local AFOS MOS Program (LAMP) and its Application to Wind Prediction  

Science Conference Proceedings (OSTI)

The Techniques Development Laboratory has a project called the local AFOS MOS Program (LAMP). Its purpose is the development of a system which can produce at any hour of the day in a Weather Service Forecast Office (WSFO) environment Model Output ...

Harry R. Glahn; David A. Unger

1986-07-01T23:59:59.000Z

233

Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference  

DOE Patents (OSTI)

An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp.

Simpson, James E. (Gaithersburg, MD)

1999-01-01T23:59:59.000Z

234

RF driven sulfur lamp having driving electrodes which face each other  

DOE Patents (OSTI)

A high intensity discharge lamp without mercury is disclosed radiating a selected spectrum of which can be almost entirely in the visible range from an envelope that contains a sulfur containing substance. The lamp utilizes a signal source that generates an excitation signal that is externally coupled to the exterior surface of the envelope to excite the enclosed sulfur containing substance. Various embodiments of the lamp use electrodes adjacent the envelope to couple the excitation signal thereto with the face of the electrodes shaped to complement the shape of the exterior surface of the envelope. Two shapes discussed are spherical and cylindrical. To minimize filamentary discharges each envelope may include an elongated stem affixed to the exterior thereof whereby a rotational subsystem spins the envelope. In yet another embodiment the envelope has a Dewar configuration with two electrodes, one positioned near the external curved side surface of the body, and a second to the inner surface of the hole through the envelope. Further, the envelope may contain a backfill of a selected inert gas to assist in the excitation of lamp with that backfill at a pressure of less than 1 atmosphere, wherein the backfill pressure is directly related to the increase or decrease of peak output and inversely related to the increase and decrease of the emitted spectrum from the envelope. The emitting fill can be less than 6 mg/cc, or at least 2 mg/cc of the envelope of a sulfur containing substance. 17 figs.

Gabor, G.; Orr, T.R.; Greene, C.M.; Crawford, D.G.; Berman, S.M.

1999-06-22T23:59:59.000Z

235

Method and apparatus for powering an electrodeless lamp with reduced radio frequency interference  

DOE Patents (OSTI)

An electrodeless lamp waveguide structure includes tuned absorbers for spurious RF signals. A lamp waveguide with an integral frequency selective attenuation includes resonant absorbers positioned within the waveguide to absorb spurious out-of-band RF energy. The absorbers have a negligible effect on energy at the selected frequency used to excite plasma in the lamp. In a first embodiment, one or more thin slabs of lossy magnetic material are affixed to the sidewalls of the waveguide at approximately one quarter wavelength of the spurious signal from an end wall of the waveguide. The positioning of the lossy material optimizes absorption of power from the spurious signal. In a second embodiment, one or more thin slabs of lossy magnetic material are used in conjunction with band rejection waveguide filter elements. In a third embodiment, one or more microstrip filter elements are tuned to the frequency of the spurious signal and positioned within the waveguide to couple and absorb the spurious signal's energy. All three embodiments absorb negligible energy at the selected frequency and so do not significantly diminish the energy efficiency of the lamp. 18 figs.

Simpson, J.E.

1999-06-08T23:59:59.000Z

236

The Fuzzy Design of the Intelligent System for the Energy-Saving Lamps  

Science Conference Proceedings (OSTI)

In the paper, a intelligent system was proposed. It consists of variable converter and intelligent controller. Variable reactor which concludes variable reactance converter and power converter has wide applications in the soft starting, speed controlling ... Keywords: fuzzy control, variable reactor, intelligent control, power converter, Energy-Saving Lamps

Youxin Yuan; Kaihua Cui; Yiping Xiao; Tieliang Xu

2008-12-01T23:59:59.000Z

237

High frequency electronic ballast for HID lamps. Technical progress report, October 1, 1993--December 31, 1994  

SciTech Connect

Electronic Ballast Systems Corp. has been working on the development of highly efficient (94%) electronic ballast for HID lamps (35W,...,400W) providing energy savings of up to thirty five percent (35%) as compared to the only available alternative, the standard core and coil HID ballasts currently on the market.

1995-03-01T23:59:59.000Z

238

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

General Service Fluorescent Lamps General Service Fluorescent Lamps Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of general service fluorescent lamps (GSFLs) since 1994. GSFLs are fluorescent tubes with pins at one or both ends for installation. These lamps are generally installed in ceilings. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates DOE published a notice of public meeting and availability of preliminary technical support document regarding energy conservation standards for GSFLs. 78 FR 13563 (February 28, 2013). DOE later published a notice of correction. 78 FR 14467 (March 6, 2013). For more information, please see the rulemaking webpage.

239

Experimental and theoretical investigations on the warm-up of a high-pressure mercury discharge lamp  

SciTech Connect

Modern high-pressure discharge lamps are forced to provide instant light and hot relight capabilities - if possible at lower power units. A detailed understanding of the warm-up of high-pressure discharge lamps is therefore required. Complex fluid model codes were developed for the past years including more and more processes like two-dimensional treatment of convection trying to provide a more comprehensive and consistent description of high-pressure discharge lamps. However, there is a lack of experimental data to examine the performance of these models. This work provides a very complete set of geometrical, electrical, spectroscopic, and thermographic data according to the warm-up of a high-pressure mercury discharge lamp that is compared to the results of a state of the art fluid code. Quantitative agreement is achieved for single parameters like wall temperatures. But the paper also reveals the need for further investigations and improvements of the code.

Zalach, J.; Franke, St.; Schoepp, H. [Leibniz Institute for Plasma Science and Technology, Felix-Hausdorff-Str. 2, D-17489 Greifswald (Germany); Araoud, Z.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, rte de Kairouan, 5019 Monastir (Tunisia); Zissis, G. [Laboratoire Plasma et Conversion d'Energie, 118 rte Narbonne, Bat3R2, 31062 Toulouse (France)

2011-03-15T23:59:59.000Z

240

House Fly Ceiling  

NLE Websites -- All DOE Office Websites (Extended Search)

NA Date: NA Question: We are a public library and have had a question regarding house flies. The question is "How high in the atmosphere can a house fly, fly? Replies:...

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Highly thermostable fluorescent proteins  

DOE Patents (OSTI)

Thermostable fluorescent proteins (TSFPs), methods for generating these and other stability-enhanced proteins, polynucleotides encoding such proteins, and assays and method for using the TSFPs and TSFP-encoding nucleic acid molecules are provided. The TSFPs of the invention show extremely enhanced levels of stability and thermotolerance. In one case, for example, a TSFP of the invention is so stable it can be heated to 99.degree. C. for short periods of time without denaturing, and retains 85% of its fluorescence when heated to 80.degree. C. for several minutes. The invention also provides a method for generating stability-enhanced variants of a protein, including but not limited to fluorescent proteins.

Bradbury, Andrew M. (Santa Fe, NM); Waldo, Geoffrey S. (Santa Fe, NM); Kiss, Csaba (Los Alamos, NM)

2011-03-22T23:59:59.000Z

242

A New Rb Lamp Exciter Circuit for Rb atomic clocks and Studies on Transition from Ring to Red mode  

E-Print Network (OSTI)

In this paper we describe the development of novel RF exciter circuit for electrode less Rb lamp. The lamp exciter circuit is a RF oscillator with a a new configuration operating at 60 to 65 MHz frequency with 3 to 4 watt power. The Rb lamp is used in exciting the ground state hyperfine transitions in Rb atom in a glass cell placed inside a tuned microwave cavity, As the frequency of these hyperfine transitions is very stable it is used in the development of Rb atomic clock by phase locking the oven controlled crystal oscillator (OCXO) to this atomic transition frequency. The details of the Rb lamp exciter are presented in the paper.The Lamp is ideally operated in ring mode as in this mode the linewidth is narrow and there is no self reversal. However, high temperature and RF excitation power may drive the Rb lamp to red mode which gives rise to line broadening and self reversal. It is the experience that mode change from ring to red deteriorates the atomic signal strength and S/N. In this paper the reasons of mode change are also discussed.

Savita Singh; Bikash Ghosal; G M Saxena

2010-11-10T23:59:59.000Z

243

Fiber bundle fluorescence endomicroscopy  

E-Print Network (OSTI)

An improved design for fiber bundle fluorescence endomicroscopy is demonstrated. Scanned illumination and detection using coherent fiber bundles with 30,000 elements with 3 ?m resolution enables high speed imaging with ...

Tsai, Tsung-Han

244

Fluorescent filtered electrophosphorescence  

DOE Patents (OSTI)

The present invention relates to organic light emitting devices (OLEDs), and more specifically to OLEDS that emit light using a combination of fluorescent emitters and phosphorescent emitters for the efficient utilization of all of the electrically generated excitons.

Forrest, Stephen (Ann Arbor, MI); Sun, Yiru (Princeton, NJ); Giebink, Noel (Ann Arbor, MI); Thompson, Mark E. (Anaheim Hills, CA)

2010-08-03T23:59:59.000Z

245

Fluorescent filtered electrophosphorescence  

DOE Patents (OSTI)

The present invention relates to organic light emitting devices (OLEDs), and more specifically to OLEDS that emit light using a combination of fluorescent emitters and phosphorescent emitters for the efficient utilization of all of the electrically generated excitons.

Forrest, Stephen R. (Princeton, NJ); Sun, Yiru (Princeton, NJ); Giebink, Noel (Princeton, NJ); Thompson, Mark E. (Anaheim Hills, CA)

2009-01-06T23:59:59.000Z

246

Compact Fluorescent Lighting in America: Lessons Learned on the Way to Market  

SciTech Connect

This report describes the history of compact fluorescent lamps (CFLs) in America. CFLs were introduced in the 1970s; however, it has taken more than 20 years for them to gain widespread recognition in the U.S. residential lighting market. This report reviews the development of CFLs, efforts to increase market acceptance of them, and barriers to that acceptance. Lessons to be learned from this study of CFLs are identified in hopes of assisting future market introduction efforts for other promising energy-efficient technologies. This report was prepared by the Pacific Northwest National Laboratory for the U.S. Department of Energy’s Office of Building Technologies, Emerging Technologies Program.

Sandahl, Linda J.; Gilbride, Theresa L.; Ledbetter, Marc R.; Steward, Heidi E.; Calwell, Chris

2006-05-22T23:59:59.000Z

247

Recombinant fluorescent protein microsphere calibration standard  

SciTech Connect

A method for making recombinant fluorescent protein standard particles for calibration of fluorescence instruments.

Nolan, John P. (Santa Fe, NM); Nolan, Rhiannon L. (Santa Fe, NM); Ruscetti, Teresa (Los Alamos, NM); Lehnert, Bruce E. (Los Alamos, NM)

2001-01-01T23:59:59.000Z

248

The Jamming point street-lamp in the world of granular media  

E-Print Network (OSTI)

The Jamming of soft spheres at zero temperature, the J-point, has been extensively studied both numerically and theoretically and can now be considered as a safe location in the space of models, where a street lamp has been lit up. However, a recent work by Ikeda et al, 2013 reveals that, in the Temperature/Packing fraction parameter space, experiments on colloids are actually rather far away from the scaling regime illuminated by this lamp. Is it that the J-point has little to say about real system? What about granular media? Such a-thermal, frictional, systems are a-priori even further away from the idealized case of thermal soft spheres. In the past ten years, we have systematically investigated horizontally shaken grains in the vicinity of the Jamming transition. We discuss the above issue in the light of very recent experimental results. First, we demonstrate that the contact network exhibits a remarkable dynamics, with strong heterogeneities, which are maximum at a packing fraction phi star, distinct and smaller than the packing fraction phi dagger, where the average number of contact per particle starts to increase. The two cross-overs converge at point J in the zero mechanical excitation limit. Second, a careful analysis of the dynamics on time scales ranging from a minute fraction of the vibration cycle to several thousands of cycles allows us to map the behaviors of this shaken granular system onto those observed for thermal soft spheres and demonstrate that some light of the J-point street-lamp indeed reaches the granular universe.

Corentin Coulais; Robert P. Behringer; Olivier Dauchot

2013-05-03T23:59:59.000Z

249

A high-efficiency indirect lighting system utilizing the solar 1000 sulfur lamp  

SciTech Connect

High-lumen light sources represent unique challenges and opportunities for the design of practical and efficient interior lighting systems. High-output sources require a means of large-scale distribution and avoidance of high-luminance glare while providing efficient delivery. An indirect lighting system has been developed for use with a 1,000 Watt sulfur lamp that efficiently utilizes the high-output source to provide quality interior lighting. This paper briefly describes the design and initial testing of this new system.

Siminovitch, M.; Gould, C.; Page, E.

1997-06-01T23:59:59.000Z

250

Super-radiance in the sodium resonance lines from sodium iodide arc lamps  

Science Conference Proceedings (OSTI)

Super-radiance observed within the centers of the sodium resonance D lines emitted by arc lamps containing sodium iodide as additive in a high-pressure mercury plasma environment was studied by high-resolution emission spectroscopy. The spectral radiance of these self-reversed lines including super-radiance was simulated by considering a local enhancement of the source function due to the presence of an additional source of radiation near the arc wall. Causes of this hitherto unrecognized source of radiation are given.

Karabourniotis, D. [Department of Physics, Institute of Plasma Physics, University of Crete, 71003 Heraklion (Greece); Drakakis, E. [Department of Electrical Engineering, Technological Educational Institute, Heraklion (Greece)

2010-08-09T23:59:59.000Z

251

Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg.sup.196 enrichment  

DOE Patents (OSTI)

The present invention is directed to a method of eliminating the cold spot zones presently used on Hg.sup.196 isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

Grossman, Mark W. (Belmont, MA)

1993-01-01T23:59:59.000Z

252

Method of controlling the mercury vapor pressure in a photo-chemical lamp or vapor filter used for Hg[sup 196] enrichment  

DOE Patents (OSTI)

The present invention is directed to a method of eliminating the cold spot zones presently used on Hg[sup 196] isotope separation lamps and filters by the use of a mercury amalgams, preferably mercury - indium amalgams. The use of an amalgam affords optimization of the mercury density in the lamp and filter of a mercury enrichment reactor, particularly multilamp enrichment reactors. Moreover, the use of an amalgam in such lamps and/or filters affords the ability to control the spectral line width of radiation emitted from lamps, a requirement for mercury enrichment.

Grossman, M.W.

1993-02-16T23:59:59.000Z

253

Section 5.4.3 Compact Fluorescent Lighting: Greening Federal...  

NLE Websites -- All DOE Office Websites (Extended Search)

2.7 m), wall-wash- ers, and decorative pendants. Retrofit lamps that contain the lamp, ballast, and screw base all in one unit are widely available. As a rule, however, these units...

254

ON-SITE DEMONSTRATION PROCEDURE FOR SOLID-STATE FLUORESCENT BALLAST  

E-Print Network (OSTI)

state ballast supplies electrical power to the lamp at acan transform the input electrical power to the lamp morethe measurement of electrical power, voltage, and current if

Verderber, Rudy

2013-01-01T23:59:59.000Z

255

Microsoft Word - FOR WEB REMOVE EDIT - Royal Pacific 33004 based on Act One 49001 NPCP  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

(ceiling fans, ceiling fan light kits, medium base compact fluorescent lamps, illuminated exit signs) ) ) ) ) ) ) ) ) Case Number: 2013-SE-33004 NOTICE OF PROPOSED CIVIL PENALTY Date issued: July 5, 2013 Number of alleged violations: 2,555 (7 basic models; 365 days) Maximum possible assessment: $511,000 Proposed civil penalty: $51,100 The U.S. Department of Energy ("DOE") Office of the General Counsel, Office of Enforcement, alleges that Royal Pacific, Ltd. ("Royal Pacific") has violated certain provisions of the Energy Policy and Conservation Act, 42 U.S.C. § 6291 et seq. ("the Act"), and 10 C.F.R. § 429.12. Specifically, DOE alleges: 1. Royal Pacific has manufactured 1 a variety of medium base compact fluorescent lamps

256

Integrated fluorescence analysis system  

DOE Patents (OSTI)

An integrated fluorescence analysis system enables a component part of a sample to be virtually sorted within a sample volume after a spectrum of the component part has been identified from a fluorescence spectrum of the entire sample in a flow cytometer. Birefringent optics enables the entire spectrum to be resolved into a set of numbers representing the intensity of spectral components of the spectrum. One or more spectral components are selected to program a scanning laser microscope, preferably a confocal microscope, whereby the spectrum from individual pixels or voxels in the sample can be compared. Individual pixels or voxels containing the selected spectral components are identified and an image may be formed to show the morphology of the sample with respect to only those components having the selected spectral components. There is no need for any physical sorting of the sample components to obtain the morphological information.

Buican, Tudor N. (Los Alamos, NM); Yoshida, Thomas M. (Los Alamos, NM)

1992-01-01T23:59:59.000Z

257

THERMAL ANNEALING OF ZNO FILMS USING HIGH-DENSITY PLASMA ARC LAMPS  

Science Conference Proceedings (OSTI)

Nanostructured materials are rarely synthesized with appropriate phase and/or morphology. In this study, critical additional of as-synthesized nanostructured materials, such as annealing and/or activation of dopants, are addressed using infrared plasma arc lamps (PAL) over areas as large as 1,000 cm2. The broad spectral range of the PAL and the spectral variation of light absorption in nanostructured materials make the selection of processing parameters extremely difficult, posing a major technological barrier. In this study, the measurement of the surface temperature using various techniques for ZnO films on crystalline silicon wafers is discussed. An energy transport model for the simulation of rapid thermal processing using PAL is presented. The experimental and computational results show that the surface temperature cannot be measured directly and that computer simulation results are an effective tool for obtaining accurate data on processing temperatures.

Sabau, Adrian S [ORNL; Dinwiddie, Ralph Barton [ORNL; Xu, Jun [ORNL; Angelini, Joseph Attilio [ORNL; Harper, David C [ORNL

2011-01-01T23:59:59.000Z

258

Archaeological data visualization in VR: analysis of lamp finds at the great temple of petra, a case study  

Science Conference Proceedings (OSTI)

We present the results of an evaluation of the ARCHAVE system, an immersive virtual reality environment for archaeological research. ARCHAVE is implemented in a Cave. The evaluation studied researchers analyzing lamp and coin finds throughout the excavation ... Keywords: archaeological data analysis, immersive virtual reality interfaces, scientific visualization

Daniel Acevedo; Eileen Vote; David H. Laidlaw; Martha S. Joukowsky

2001-10-01T23:59:59.000Z

259

Appliance Standard Program - The FY 2003 Priority -Setting Summary...  

NLE Websites -- All DOE Office Websites (Extended Search)

Fluorescent Lamp Ballasts Electric Motors, 1-200HP Fluorescent Lamps Commercial Oil- and Gas-Fired Packaged Boilers Mobile Home Furnaces High-Intensity Discharge Lamps...

260

Fluorescence analyzer for lignin  

SciTech Connect

A method and apparatus for measuring lignin concentration in a sample of wood pulp or black liquor comprises a light emitting arrangement for emitting an excitation light through optical fiber bundles into a probe which has an undiluted sensing end facing the sample. The excitation light causes the lignin concentration to produce fluorescent emission light which is then conveyed through the probe to analyzing equipment which measures the intensity of the emission light. Measures a This invention was made with Government support under Contract Number DOE: DE-FC05-90CE40905 awarded by the Department of Energy (DOE). The Government has certain rights in this invention.

Berthold, John W. (Salem, OH); Malito, Michael L. (Hubbard, OH); Jeffers, Larry (Alliance, OH)

1993-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Fluorescent temperature sensor  

Science Conference Proceedings (OSTI)

The present invention is a fluorescent temperature sensor or optical thermometer. The sensor includes a solution of 1,3-bis(1-pyrenyl)propane within a 1-butyl-1-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide ionic liquid solvent. The 1,3-bis(1-pyrenyl)propane remains unassociated when in the ground state while in solution. When subjected to UV light, an excited state is produced that exists in equilibrium with an excimer. The position of the equilibrium between the two excited states is temperature dependent.

Baker, Gary A [Los Alamos, NM; Baker, Sheila N [Los Alamos, NM; McCleskey, T Mark [Los Alamos, NM

2009-03-03T23:59:59.000Z

262

Application of a three-dimensional model for a study of the energy transfer of a high-pressure mercury horizontal lamp  

Science Conference Proceedings (OSTI)

This paper is devoted to study the dynamics of a discharge lamp with high intensity in a horizontal position. As an example of application, we chose the high-pressure mercury lamp. For this, we realized a three-dimensional model, a stable and powered DC. After the validation of this model, we used it to reproduce the influence of some parameters that have appeared on major transport phenomena of mass and energy in studying the lamp operating in a horizontal position. Indeed, the mass of mercury and the electric current are modified and the effect of convective transport is studied.

Ben Hamida, M. B.; Charrada, K. [Unite d'Etude des Milieux Ionises et Reactifs, IPEIM, 5019 route de Kairouan Monastir (Tunisia)

2012-06-15T23:59:59.000Z

263

Evaluating the Impact of the  

E-Print Network (OSTI)

simulated using linear fluorescent lamps with correlated color temperatures of 5000K. Yet, the variability among linear fluorescent lamp systems, which include the lamp, ballast and reflector, is great Linear Fluorescent Lamps Fluorescent lamps are produced in many different forms. Linear fluorescent lamps

Zanibbi, Richard

264

Method and apparatus for mounting a dichroic mirror in a microwave powered lamp assembly using deformable tabs  

DOE Patents (OSTI)

A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet. 7 figs.

Ury, M.; Sowers, F.; Harper, C.; Love, W.

1998-11-24T23:59:59.000Z

265

Method and apparatus for mounting a dichroic mirror in a microwave powered lamp assembly using deformable tabs  

DOE Patents (OSTI)

A microwave powered electrodeless lamp includes an improved screen unit having mesh and solid sections with an internal reflector secured at the juncture of the two sections to reflect light into a light-transmitting chamber defined in the lamp microwave cavity by the reflector and the mesh section. A discharge envelope of a bulb is disposed in the light-transmitting chamber. Light emitted from the envelope is prevented by the reflector from entering the cavity portion bounded by the solid section of the screen. The reflector is mounted in the cavity by tabs formed in the screen unit and bendable into the cavity to define support planes abutting respective surfaces of the reflector. The mesh section and tabs are preferably formed by etching a thin metal sheet.

Ury, Michael (Bethesda, MD); Sowers, Frank (Frederick, MD); Harper, Curt (Wheaton, MD); Love, Wayne (Olney, MD)

1998-01-01T23:59:59.000Z

266

Mechanical design of PlayLamp : a minimally intrusive device for recording the behavior of children at-risk of developmental disorders  

E-Print Network (OSTI)

This thesis paper documents the design process, decisions, and outcomes of the design of the physical form factor of PlayLamp, a device for video and audio recording the development of children at-risk of having developmental ...

Steger, Stephen Andrew

2008-01-01T23:59:59.000Z

267

Nuclear Resonance Fluorescence for Materials Assay  

E-Print Network (OSTI)

clandestine material with nuclear resonance fluorescence”.E. Norman, UC Berkeley Dept. of Nuclear Engineering, privatepp. 349. G. Warren et al. “Nuclear Resonance Fluorescence of

Quiter, Brian

2010-01-01T23:59:59.000Z

268

Observed Minimum Illuminance Threshold for Night Market Vendors in Kenya who use LED Lamps  

Science Conference Proceedings (OSTI)

Creation of light for work, socializing, and general illumination is a fundamental application of technology around the world. For those who lack access to electricity, an emerging and diverse range of LED based lighting products hold promise for replacing and/or augmenting their current fuel-based lighting sources that are costly and dirty. Along with analysis of environmental factors, economic models for total cost-ofownership of LED lighting products are an important tool for studying the impacts of these products as they emerge in markets of developing countries. One important metric in those models is the minimum illuminance demanded by end-users for a given task before recharging the lamp or replacing batteries. It impacts the lighting service cost per unit time if charging is done with purchased electricity, batteries, or charging services. The concept is illustrated in figure 1: LED lighting products are generally brightest immediately after the battery is charged or replaced and the illuminance degrades as the battery is discharged. When a minimum threshold level of illuminance is reached, the operational time for the battery charge cycle is over. The cost to recharge depends on the method utilized; these include charging at a shop at a fixed price per charge, charging on personal grid connections, using solar chargers, and purchasing dry cell batteries. This Research Note reports on the observed"charge-triggering" illuminance level threshold for night market vendors who use LED lighting products to provide general and task oriented illumination. All the study participants charged with AC power, either at a fixed-price charge shop or with electricity at their home.

Johnstone, Peter; Jacobson, Arne; Mills, Evan; Radecsky, Kristen

2009-03-21T23:59:59.000Z

269

GLASS AND GLASS-DERIVATIVE SEALS FOR USE IN ENERGY-EFFICIENT FUEL CELLS AND LAMPS  

DOE Green Energy (OSTI)

As the project approaches the end of the first year, the materials screening components of the work are ahead of schedule, while all other tasks are on schedule. For solid oxide fuel cells (SOFC), a series of 16 sealing glasses have been prepared and characterized. Traditional melting was used to prepare all of the glasses, and the sol-gel approach has been used to prepare some of the glasses as well as other compositions that might be viable because of the low processing temperatures afforded by the sol-gel method. The glass characterization included measurements of the viscosity and thermal expansion of the glasses, as well as the thermal expansion of the partly crystalline glass ceramics. In addition, the wetting and sintering behavior of all glasses has been measured, as well as the crystallization behavior. The time and temperature at which crystalline phases form from the glasses has been determined for all of the glasses. Each glass ceramic contains at least two crystalline phases, and most of the crystalline phases have been positively identified. Room temperature leak testing has been completed for all sealants, and experiments are in progress to determine the DC electrochemical degradation and degradation in wet hydrogen. The second component of the work, focused on seals for higher-temperature discharge lighting, has focused on determining the phase relations in the yttria--alumina--silica system at various silica levels. Again, traditional melting and sol-gel synthesis have been employed, and the sol-gel method was successful for preparing new phases that were discovered during the work. High temperature diffraction and annealing studies have clarified the phase relations for the samples studies, although additional work remains. Four new phases have been identified and synthesized in pure form, from which full structure solutions were obtained as well as the anisotropic thermal expansion for each phase. Functional testing of lamps are on on-going and will be analyzed during year 2 of the contract.

Scott Misture; Arun Varshneya; Matthew Hall; Sylvia DeCarr; Steve Bancheri

2004-08-15T23:59:59.000Z

270

A Review of the Reflector Compact Fluorescent Lights Technology Procurement Program: Conclusions and Results  

SciTech Connect

This report describes a project sponsored by the U.S. Department of Energy (DOE) and implemented by the Pacific Northwest National Laboratory (PNNL), from 2000 to 2007 to improve the performance of reflector type (R-lamp) compact fluorescent lamps (CFLs) and increase their availability throughout the United States by means of a technology development and procurement strategy. In 2000, at the request of the U.S. Department of Energy’s Emerging Technologies Program and its predecessors, the Pacific Northwest National Laboratory undertook a technology procurement seeking R-CFLs that were specifically designed for use in ICAT recessed can fixtures and that met other minimum performance criteria including minimum light output and size restrictions (to ensure they fit in standard residential recessed cans). The technology procurement included two phases. In Phase I, requests for proposals (RFPs) were issued in October 2002 and five manufacturers responded with 12 lamp models. Eight of these models met the minimum requirements and passed the 6-hour short-term test in a simulated ICAT environment. These eight models were subjected to long-term tests of 6,000 or more hours in a simulated ICAT environment. Three of these models passed the short- and long-term tests and were promoted through the program website (www.pnl.gov/rlamps), press releases, and fliers. To increase the number of qualifying models, a second RFP was issued in June 2005. In April 2007, DOE announced that 16 reflector CFL (R-CFL) models by four manufacturers had met all the minimum requirements of Phase 2 of the R-CFL Technology Innovation Competition. PNNL developed both the criteria and the test apparatus design for Elevated Temperature Life Testing (ETLT), which has been included by DOE in its draft ENERGY STAR specifications for the reflector category of CFLs. PNNL promoted the winning lamps through a program website, press releases, and fliers as well as through program partners. PNNL also helped engage distributors including Costco, the Home Depot, Bonneville Power Administration, and utility organizations.

Sandahl, Linda J.; Gilbride, Theresa L.; Ledbetter, Marc R.; McCullough, Jeffrey J.

2008-05-19T23:59:59.000Z

271

L&E - high efficiency lighting for parking structure | The Better Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

structure structure Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Adopt high-efficiency lighting for your parking structure Parking structures and garages are typically lighted by older HID lighting technology without any energy-saving controls. The latest high-efficiency alternatives with energy-saving controls-including light-emitting diode (LED), induction, and fluorescent technology options-can save building owners over 40% on their parking lot lighting bills while delivering additional benefits such as better-lighted spaces. The Lighting & Electrical team developed a performance specification that

272

Nuclear Resonance Fluorescence for Nuclear Materials Assay  

E-Print Network (OSTI)

Potential of Nuclear Resonance Fluorescence . . . . . . . .2.9.1 Nuclear ThomsonSections . . . . . . . . . . . . . . . Nuclear Resonance

Quiter, Brian Joseph

2010-01-01T23:59:59.000Z

273

Glass and glass-derivative seals for use in energy-efficient fuel cells and lamps  

DOE Green Energy (OSTI)

For solid oxide fuel cells (SOFC), a series of 18 sealing glasses have been prepared and characterized. From the whole design space, several glasses were ''downselected'' and studied in detail to describe their behaviors in simulated fuel cell environments. One of the glasses was found to outperform all others, including the well-known G18 sealant developed at Pacific Northwest National Laboratory. The new glass composition showed lower bulk electrical conductivity, excellent sealing and wetting behavior when sealing under applied load, and qualitatively superior performance when exposed to wet hydrogen for 800 hours. Traditional melting was used to prepare all of the glasses that were studied in detail. The sol-gel approach was used to synthesize several compositions, but it was found that the glasses crystallized very rapidly during heating, precluding sealing. The glass characterization included measurements of the viscosity and thermal expansion of the glasses, as well as the thermal expansion of the partly crystalline glass ceramics. In addition, the wetting and sintering behavior of all glasses has been measured, as well as the crystallization behavior. The time and temperature at which crystalline phases form from the glasses has been determined for all of the glasses. Each glass ceramic contains at least two crystalline phases, and most of the crystalline phases have been positively identified. The body of fundamental data provides a platform for future developments for high temperature sealants, and the newly-developed glass compositions appear promising for large-scale testing. The second component of the work, focused on seals for higher-temperature discharge lighting, has focused on determining the phase relations in the yttria-alumina-silica system at various silica levels. Functional testing of one of the candidate sealants demonstrated that it performs well in current HID lighting applications. Further testing is required to evaluate its performance in next-generation lamps that operate at higher temperatures, but the baseline phase equilibria and crystallization behavior has been established for additional development. Again, traditional melting and sol-gel synthesis have been employed, and the sol-gel method was successful for preparing new phases that were discovered during the work. Four new phases have been identified and synthesized in pure form, from which full structure solutions were obtained as well as the anisotropic thermal expansion for each phase.

Scott Misture; Arun Varshineya; Matthew Hall; Sylvia DeCarr; Steve Bancheri

2005-07-28T23:59:59.000Z

274

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

certain lighting system components, but with only minor exceptions (torchieres, ceiling fan light kits, exit signs, traffic signals, and metal halide lamp fixtures), has not...

275

L&E: Participate in a field test for high-efficiency troffer lighting. |  

NLE Websites -- All DOE Office Websites (Extended Search)

Lighting & Electrical » Participate Lighting & Electrical » Participate in a field test for high efficiency troffer lighting Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Participate in a field test for high-efficiency troffer lighting 50% of all commercial fluorescent lighting fixtures are recessed troffers in 1'x4', 2'x2' and 2'x4' configurations, in operation for more than 10 hours a day on average and collectively consuming more than 87 TWh of electricity annually. The Lighting & Electrical team supported the market introduction of high-efficiency troffers by developing a specification that allows for

276

PHASE I FINAL REPORT SUBCONTRACT NO. 2019702 "ENERGY EFFICIENT FLUORESCENT BALLASTS"  

E-Print Network (OSTI)

Stabilize ballast at 235 volts input AC for 60 seconds withI Sec. (Lamp) E Cathode Ckt Volt: Yel Dum. Load Full. L.O.Factor Same lamps used = Watts/Volt-Amps, Approx. accuracy +

Authors, Various

2011-01-01T23:59:59.000Z

277

Replacing Fluorescent Lightbulbs | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Replacing Fluorescent Lightbulbs Replacing Fluorescent Lightbulbs Replacing Fluorescent Lightbulbs July 29, 2012 - 6:37pm Addthis Although fluorescent lightbulbs are generally energy efficient, you can replace them with new, even more efficient bulbs that use better electrodes and coatings than older ones. | Photo courtesy of ©iStockphoto.com/JoLin. Although fluorescent lightbulbs are generally energy efficient, you can replace them with new, even more efficient bulbs that use better electrodes and coatings than older ones. | Photo courtesy of ©iStockphoto.com/JoLin. What does this mean for me? Today's fluorescent light fixtures and bulbs are far more efficient than older ones. You can replace fluorescent bulbs and ballasts with more efficient ones to save money and energy. All fluorescent bulbs contain a very small amount of mercury:

278

Measuring the Natural Fluorescence of Phytoplankton Cultures  

Science Conference Proceedings (OSTI)

A laboratory instrument, the Natural Fluorescence Chemostat, was developed to measure the natural fluorescence of phytoplankton cultures. With this instrument, the physical and chemical environment of a culture can be manipulated with respect to ...

S. R. Laney; R. M. Letelier; R. A. Desiderio; M. R. Abbott; D. A. Kiefer; C. R. Booth

2001-11-01T23:59:59.000Z

279

Quantum Dot Fluorescence Lifetime Engineering with DNA ...  

Science Conference Proceedings (OSTI)

Quantum Dot Fluorescence Lifetime Engineering with DNA Origami ... such as metal nanoparticles and semiconductor quantum dots – is challenging ...

280

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 2, Fluorescent lamp ballasts, television sets, room air conditioners, and kitchen ranges and ovens  

SciTech Connect

This document is divided into ``volumes`` B through E, dealing with individual classes of consumer products. Chapters in each present engineering analysis, base case forecasts, projected national impacts of standards, life-cycle costs and payback periods, impacts on manufacturers, impacts of standards on electric utilities, and environmental effects. Supporting appendices are included.

Not Available

1993-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Exploration of illumination concepts for underground coal mines. Appendix E. Electronic ballast for the Lucalox high pressure sodium lamp. Final report  

SciTech Connect

The report documents the results of an investigation to develop solid-state ballasts for Lucalox high-pressure sodium lamps. The ballasts were to be used in the modified and new portable and machine-mounted lighting systems designed by the Crouse-Hinds Co., per tasks I through IV of Contract No. H022065.

1976-07-20T23:59:59.000Z

282

Three-dimensional fluorescence lifetime tomography  

Science Conference Proceedings (OSTI)

Near-infrared fluorescence tomography using molecularly targeted lifetime-sensitive, fluorescent contrast agents have applications for early-stage cancer diagnostics. Yet, although the measurement of fluorescent lifetime imaging microscopy (FLIM) is extensively used in microscopy and spectroscopy applications, demonstration of fluorescence lifetime tomography for medical imaging is limited to two-dimensional studies. Herein, the feasibility of three-dimensional fluorescence-lifetime tomography on clinically relevant phantom volumes is established, using (i) a gain-modulated intensified charge coupled device (CCD) and modulated laser diode imaging system, (ii) two fluorescent contrast agents, e.g., Indocyanine green and 3-3'-Diethylthiatricarbocyanine iodide differing in their fluorescence lifetime by 0.62 ns, and (iii) a two stage approximate extended Kalman filter reconstruction algorithm. Fluorescence measurements of phase and amplitude were acquired on the phantom surface under different target to background fluorescence absorption (70:1, 100:1) and fluorescence lifetime (1:1, 2.1:1) contrasts at target depths of 1.4-2 cm. The Bayesian tomography algorithm was employed to obtain three-dimensional images of lifetime and absorption owing to the fluorophores.

Godavarty, Anuradha; Sevick-Muraca, Eva M.; Eppstein, Margaret J. [327 Votey Building, Department of Computer Science, University of Vermont, Burlington, Vermont 05405 (United States); 1011 Richardson Building, Photon Migration Laboratories, Texas A and M University, College Station, Texas 77843 (United States); 327 Votey Building, Department of Computer Science, University of Vermont, Burlington, Vermont 05405 (United States)

2005-04-01T23:59:59.000Z

283

SDG&E (Electric) - Multi-Family Residential Efficiency Program | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Multi-Family Residential Efficiency Program Multi-Family Residential Efficiency Program SDG&E (Electric) - Multi-Family Residential Efficiency Program < Back Eligibility Multi-Family Residential Savings Category Home Weatherization Commercial Weatherization Heating & Cooling Cooling Commercial Heating & Cooling Appliances & Electronics Heat Pumps Commercial Lighting Lighting Water Heating Program Info State California Program Type Utility Rebate Program Rebate Amount Clothes Washers: $75-$150 Room Air Conditioner: $50 Central Heat Pumps: $100 Insulation: $0.15/sq. ft. CFLs: $4-$10 Ceiling Fans with CFLs: $20 Interior Hardwired Fluorescent Fixtures: $32-$45 Exterior Hardwired Fluorescent Fixtures: $30 T12 De-lamping: $6/lamp Water Heaters: $30 Occupancy Sensors: $10 LED Exit Signs: $35 Photocells: $10/unit

284

Bremsstrahlung-induced K fluorescence  

SciTech Connect

Bremsstrahlung radiation can be used to excite nearly monoenergetic x rays in secondary targets, which are then used to study the energy response of radiation detectors if the intensity and purity are known. A method is suggested for calculating the spectral intensity of the secondary target radiation, including K-fluorescent x rays, and the bremsstrahlung and characteristic line radiation scattered from the target. Coherent and incoherent scatter are included in the calculation. To test the theory, bremsstrahlung radiation from an x-ray unit operating in the 100- to 300-kV potential range was used to excite K-fluorescent radiation in secondary targets that range in atomic number from 29 to 90. The primary and secondary spectra were measured with NaI, silicon, and germanium detectors. The measured primary spectral intensities were used as input to the secondary spectral intensity calculation. Calculated secondary spectra were within 20 percent agreement with measurement. Optimization of the secondary target intensity and purity is discussed as a function of target thickness, potential, and selective filtration.

Storm, E.

1976-09-01T23:59:59.000Z

285

Sandia National Laboratories Fluorescent Optical Position Sensor  

As shown in the figure, a small excitation source, such as a laser or LED, excites a localized area of fluorescence at an unknown position along the

286

Portable spotter for fluorescent contaminants on surfaces  

DOE Patents (OSTI)

A portable fluorescence-based spotter for polynuclear aromatic hydrocarbon contamination on personnel and work area surfaces under ambient lighting conditions is provided. This instrument employs beam modulation and phase sensitive detection for discriminating between fluorescence from organic materials from reflected background light and inorganic fluorescent material. The device uses excitation and emission filters to provide differentiation between classes of aromatic organic compounds. Certain inorganic fluorescent materials, including heavy metal compounds, may also be distinguished from the organic compounds, despite both having similar optical properties.

Schuresko, Daniel D. (Oak Ridge, TN)

1980-01-01T23:59:59.000Z

287

Demonstration of LED Retrofit Lamps at an Exhibit of 19th Century Photography at the Getty Museum  

SciTech Connect

This document is a report of observations and results obtained from a lighting demonstration project conducted under the U.S. Department of Energy (DOE) GATEWAY Demonstration Program. The program supports demonstrations of high-performance solid-state lighting (SSL) products in order to develop empirical data and experience with in-the-field applications of this advanced lighting technology. The DOE GATEWAY Demonstration Program focuses on providing a source of independent, third-party data for use in decision-making by lighting users and professionals; this data should be considered in combination with other information relevant to the particular site and application under examination. Each GATEWAY Demonstration compares SSL products against the incumbent technologies used in that location. Depending on available information and circumstances, the SSL product may also be compared to alternate lighting technologies. Though products demonstrated in the GATEWAY program may have been prescreened for performance, DOE does not endorse any commercial product or in any way guarantee that users will achieve the same results through use of these products. This report reviews the installation and use of LED PAR38 lamps to light a collection of toned albument photographic prints at the J. Paul Getty Museum in Malibu, California. Research results provided by the Getty Conservation Institute are incorporated and discussed.

Miller, Naomi J.; Druzik, Jim

2012-03-02T23:59:59.000Z

288

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

have been required to comply with the Department of Energy (DOE) energy conservation standards for fluorescent lamp ballasts since 1990. Fluorescent lamp ballasts control electric...

289

EA-1881: Energy Conservation Program: Energy Conservation Standards...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts EA-1881: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp...

290

Federal Energy Management Program: Federal Energy Efficiency...  

NLE Websites -- All DOE Office Websites (Extended Search)

Fluorescent Tube Lamps FEMP temporarily suspended its energy efficiency requirements for fluorescent tube lamps as it evaluates the market impact of the pending 2012 minimum...

291

DOE CALiPER Program, Report 20.1 Subjective Evaluation of Beam Quality, Shadow Quality, and Color Quality for LED PAR38 Lamps  

Science Conference Proceedings (OSTI)

This report focuses on human-evaluated characteristics, including beam quality, shadow quality, and color quality. Using a questionnaire that included rank ordering, opinions on 27 of the Report 20 PAR38 lamps were gathered during a demonstration event for members of the local Illuminating Engineering Society (IES) chapter. This was not a rigorous scientific experiment, and the data should not be extrapolated beyond the scope of the demonstration. The results suggest that many of the LED products compared favorably to halogen PAR38 benchmarks in all attributes considered. LED lamps using a single-emitter design were generally preferred for their beam quality and shadow quality, and the IES members ranking of color quality did not always match the rank according to the color rendering index (CRI).

Royer, Michael P.; Poplawski, Michael E.; Miller, Naomi J.

2013-10-01T23:59:59.000Z

292

Atomic gas temperature in a nonequilibrium high-intensity discharge lamp determined from the red wing of the resonance mercury line 254 nm  

Science Conference Proceedings (OSTI)

For developing low-wattage high intensity discharge (HID) lamps, a better understanding of the relatively unexplored nonequilibrium phenomena is essential. This needs interpretation of diagnostic results by methods free from equilibrium assumptions. In this paper, the atomic temperature is determined from the simulation of a quasistatic broadened resonance line by distinguishing between atomic temperature and excitation temperature in the equation of radiative transfer. The proposed method is applied to the red wing of the resonance mercury line 254 nm emitted from a HID lamp working on ac. The experimental results show severe deviation from local thermodynamic equilibrium. More than one thousand degrees difference was obtained between atomic and electron temperatures at the maximum current phase.

Drakakis, E. [Technological Educational Institute, Department of Electrical Engineering, 71004 Heraklion (Greece); Karabourniotis, D. [Institute of Plasma Physics, Department of Physics, University of Crete, 71003 Heraklion (Greece)

2012-09-01T23:59:59.000Z

293

PEVELOPMENT OF FLUORESCENCE LIFETIME DIAGNOSTIC  

Office of Scientific and Technical Information (OSTI)

4 4 PEVELOPMENT OF FLUORESCENCE LIFETIME DIAGNOSTIC w I Project Accomplishments Summary (Attachment I) CRADA NO. TSB-1449-97 Date: U 1 8 1 9 8 Revision: 1 A . Parties The project is a relationship between the Lawrence Livennore National Laboratoq (LLNL) and Optiphase, Inc. University of California Lawrence Livermore National Laboratory 7000 East Avenue, L-399 Livermore, CA 94550 Optiphase, h c 7652 Haskell Ave. Van Nuys, CA 91406 Technical Contact - D r . Pepe Davis (8 18)782-0997ext 1 12 B . Background Fiber-optic-based sensors are excellent candidates for detecting the presence and monitoring the levels of degradation products in stockpiled weapons. Specifically, fl uorescence-based sensors are extremely sensitive, can have high specificity for compounds of interest, and are "e~ectrically

294

Applications of Nuclear Resonance Fluorescence  

Science Conference Proceedings (OSTI)

Nuclear Resonance Fluorescence (NRF) has the potential of addressing a wide variety of applications, which require isotopic and/or elemental information about a sample. We have investigated a variety of non-proliferation applications that may be addressed by NRF. From these applications, we have selected two, measuring uranium enrichment in UF6 cylinders and material verification in dismantlement, to investigate in more detail. Analytical models have been developed to evaluate these applications, and test measurements have been conducted to validate those models. We found that it is unlikely with current technology to address the requirements for UF6 cylinder enrichment measurements. In contrast, NRF is a very promising approach for material verification for dismantlement.

Warren, Glen A.; Detwiler, Rebecca S.; Peplowski, Patrick N.

2010-11-11T23:59:59.000Z

295

Fiber optical assembly for fluorescence spectrometry  

DOE Patents (OSTI)

A system for analyzing a sample for the presence of an analyte in a sample. The system includes a sample holder for containing the sample; an excitation source, such as a laser, and at least one linear array radially disposed about the sample holder. Radiation from the excitation source is directed to the sample, and the radiation induces fluorescent light in the sample. Each linear array includes a plurality of fused silica optical fibers that receive the fluorescent light and transmits a fluorescent light signal from the first end to an optical end port of the linear array. An end port assembly having a photo-detector is optically coupled to the optical end port. The photo-detector detects the fluorescent light signal and converts the fluorescent light signal into an electrical signal.

Carpenter, II, Robert W. (Pagosa Springs, CO); Rubenstein, Richard (Staten Island, NY); Piltch, Martin (Los Alamos, NM); Gray, Perry (Los Alamos, NM)

2010-12-07T23:59:59.000Z

296

Evaluation of plant seedling water stress using dynamic fluorescence index with blue LED-based fluorescence imaging  

Science Conference Proceedings (OSTI)

A dynamic fluorescence image index system capable of non-destructive assessment of water stress in cabbage seedlings was developed. The quenching curves of chlorophyll fluorescence characteristic to the plant's water stress status under reduced excitation ... Keywords: Chlorophyll fluorescence, Fluorescence image, Fluorescence index, Water stress

Shih-Chieh Hsiao; Suming Chen; I-Chang Yang; Chia-Tseng Chen; Chao-Yin Tsai; Yung-Kun Chuang; Feng-Jehng Wang; Yu-Liang Chen; Tzong-Shyan Lin; Y. Martin Lo

2010-07-01T23:59:59.000Z

297

Building America Efficient Solutions for Existing Homes Case Study: Habitat for Humanity of Palm Beach County, Lake Worth, Florida  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Project Description Project Description Habitat for Humanity of Palm Beach County, working with Building America researchers from Pacific Northwest National Laboratory and the Florida Solar Energy Center, upgraded this previously unoccupied 1996 home in Lake Worth, Florida to achieve an estimated 39% improvement in energy efficiency. The 1,573-ft 2 slab-on-grade, single- family home received extensive energy upgrades during its conversion to affordable and efficient housing for low-income families. By replacing the home's water heater, using compact fluorescent lamps (CFLs), reducing air infiltration, adding more ceiling insulation, and installing a central air conditioner, the home's annual energy bills are

298

Royal Pacific: Proposed Penalty (2013-SE-33004) | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Proposed Penalty (2013-SE-33004) Proposed Penalty (2013-SE-33004) Royal Pacific: Proposed Penalty (2013-SE-33004) July 5, 2013 DOE alleged in a Notice of Proposed Civil Penalty that Royal Pacific, Ltd. failed to certify ceiling fans, ceiling fan light kits, medium base compact fluorescent lamps, and illuminated exit signs as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. Royal Pacific: Proposed Penalty (2013-SE-33004) More Documents & Publications

299

All General Counsel Reports | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

July 8, 2013 July 8, 2013 Class Patent Waiver W(C)2012-007 This is a request by SOLID-STATE LIGHTING ROUND 4 for a DOE Class patent waiver of domestic and foreign patent rights under agreement DE-FOA-0000792. July 8, 2013 Hicon: Proposed Penalty (2013-SE-1426) DOE alleged in a Notice of Proposed Civil Penalty that Ningbo Hicon International Industry Company, Ltd. manufactured and distributed noncompliant freezer basic model BD-200 in the U.S. July 5, 2013 Royal Pacific: Proposed Penalty (2013-SE-33004) DOE alleged in a Notice of Proposed Civil Penalty that Royal Pacific, Ltd. failed to certify ceiling fans, ceiling fan light kits, medium base compact fluorescent lamps, and illuminated exit signs as compliant with the applicable energy conservation standards. July 1, 2013

300

All General Counsel Reports | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

July 30, 2013 July 30, 2013 Royal Pacific: Order (2013-SE-33004) DOE ordered Royal Pacific, Ltd. to pay a $8,000 civil penalty after finding Royal Pacific had failed to certify that various basic models of medium base compact fluorescent lamps, ceiling fans, ceiling fan light kits, and illuminated exit signs comply with the applicable energy conservation standards. July 29, 2013 DOE Retrospective Review Plan and Burden Reduction Report July 29, 2013 July 24, 2013 Dialight: Proposed Penalty (2013-CE-4902) DOE alleged in a Notice of Proposed Civil Penalty that Dialight Corporation failed to certify a variety of traffic signal modules and pedestrian modules as compliant with the applicable energy conservation standards. July 23, 2013 Trastar: Proposed Penalty (2013-CE-49003)

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Using Nuclear Resonance Fluorescence for Nondestructive Isotopic Analysis  

E-Print Network (OSTI)

7, (1959) pp. 54. [12] B.J. Quiter, ``Nuclear ResonanceFluorescence for Nuclear Materials Assay,'' University ofclandestine material with nuclear resonance fluorescence,"

Ludewigt, Bernhard A.

2010-01-01T23:59:59.000Z

302

Mercury-free fluorescent lighting  

Science Conference Proceedings (OSTI)

A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct measurement of the radiance (power per unit area per unit solid angle) at 147 nm using a calibrated VUV photodiode, and a calculation of the relative angular distribution of the resonance radiation to determine the radiant emittance. In both techniques a simulation of the transport of resonance radiation is key to determining the radiant emittance.

Doughty, D.A. [General Electric Corporate Research and Development, Schenectady, NY (United States)

1996-05-01T23:59:59.000Z

303

Reflector-coupled fluorescent solar collector  

SciTech Connect

The present invention provides a system for the collection of electromagnetic radiation and the transmission of that radiation to a point of use. In its simplest sense, an apparatus for the collection and transmission of electromagnetic radiation comprises a cylindrical fluorescent fiber, at least one end of which is optically coupled to an optical wave guide, and means for reflecting solar radiation impinging over a relatively wide area onto said cylindrical fluorescent fiber. Preferably, a compound parabolic mirror is employed for reflecting incident solar radiation onto the optical fluorescent fiber.

Younghouse, L.B.

1984-01-17T23:59:59.000Z

304

Phosphors for LED lamps  

DOE Patents (OSTI)

A phosphor, a phosphor blend including the phosphor, a phosphor prepared by a process, and a lighting apparatus including the phosphor blend are disclosed. The phosphor has the formula (Ca.sub.1-p-qCe.sub.pK.sub.q).sub.xSc.sub.y(Si.sub.1-rGa.sub.r).sub.zO.su- b.12+.delta. or derived from a process followed using disclosed amounts of reactants. In the formula, (0

Murphy, James Edward; Manepalli, Satya Kishore; Kumar, Prasanth Nammalwar

2013-08-13T23:59:59.000Z

305

Green fluorescent protein as a mechanical sensor  

E-Print Network (OSTI)

Inquiry into intracellular and cytoskeletal mechanics requires an intracellular mechanical sensor to verify models of sub-cellular structure dynamics. To this end, the green fluorescent protein (GFP) is considered as a ...

Muso, Taro M. (Taro Michael)

2007-01-01T23:59:59.000Z

306

Nuclear Resonance Fluorescence for Nuclear Materials Assay.  

E-Print Network (OSTI)

??This dissertation examines the measurement of nuclear resonance fluorescence gamma-rays as a technique to non-destructively determine isotopic compositions of target materials that are of interest… (more)

Quiter, Brian Joseph

2010-01-01T23:59:59.000Z

307

LASER INDUCED FLUORESCENCE OF TRAPPED MOLECULAR IONS  

E-Print Network (OSTI)

System Laser Power Measurement Wavelength Calibration SystemLaser Power Measurement Wavelength Calibration PAGE Fluorescence Detection Systemmeasurement system. The actual time for initiation of the detection gate with respect to the laser

Grieman, Frederick Joseph.

2010-01-01T23:59:59.000Z

308

Multiplexed fluorescence detector system for capillary electrophoresis  

DOE Patents (OSTI)

A fluorescence detection system for capillary electrophoresis is provided wherein the detection system can simultaneously excite fluorescence and substantially simultaneously monitor separations in multiple capillaries. This multiplexing approach involves laser irradiation of a sample in a plurality of capillaries through optical fibers that are coupled individually with the capillaries. The array is imaged orthogonally through a microscope onto a charge-coupled device camera for signal analysis. 14 figs.

Yeung, E.S.; Taylor, J.A.

1996-03-12T23:59:59.000Z

309

Laser excited confocal microscope fluorescence scanner and method  

DOE Patents (OSTI)

A fluorescent scanner for scanning the fluorescence from a fluorescence labeled separated sample on a sample carrier including a confocal microscope for illuminating a predetermined volume of the sample carrier and/or receiving and processing fluorescence emissions from said volume to provide a display of the separated sample.

Mathies, Richard A. (Contra Costa, CA); Peck, Konan (Contra Costa, CA)

1992-01-01T23:59:59.000Z

310

Ultratrace analysis of transuranic actinides by laser-induced fluorescence  

DOE Patents (OSTI)

Ultratrace quantities of transuranic actinides are detected indirectly by their effect on the fluorescent emissions of a preselected fluorescent species. Transuranic actinides in a sample are coprecipitated with a host lattice material containing at least one preselected fluorescent species. The actinide either quenches or enhances the laser-induced fluorescence of the preselected fluorescent species. The degree of enhancement or quenching is quantitatively related to the concentration of actinide in the sample.

Miller, Steven M. (Chelmsford, MA)

1988-01-01T23:59:59.000Z

311

EA-1881: Finding of No Significant Impact  

Energy.gov (U.S. Department of Energy (DOE))

Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts (October 2011)

312

EA-1881: Final Environmental Assessment  

Energy.gov (U.S. Department of Energy (DOE))

Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts (October 2011)

313

Time dependence of liquid-helium fluorescence  

SciTech Connect

The time dependence of extreme ultraviolet (EUV) fluorescence following an ionizing radiation event in liquid helium is observed and studied in the temperature range from 250 mK to 1.8 K. The fluorescence exhibits significant structure including a short ({approx}10 ns) strong initial pulse followed by single photons whose emission rate decays exponentially with a 1.6-{mu}s time constant. At an even longer time scale, the emission rate varies as '1/time' (inversely proportional to the time after the initial pulse). The intensity of the '1/time' component from {beta} particles is significantly weaker than those from {alpha} particles or neutron capture on {sup 3}He. It is also found that for {alpha} particles, the intensity of this component depends on the temperature of the superfluid helium. Proposed models describing the observed fluorescence are discussed.

McKinsey, D.N.; Brome, C.R.; Dzhosyuk, S.N.; Mattoni, C.E.H.; Yang, L.; Doyle, J.M. [Department of Physics, Harvard University, Cambridge, Massachusetts 02138 (United States); Golub, R.; Habicht, K.; Korobkina, E. [Hahn-Meitner Institut, Berlin-Wannsee (Germany); Huffman, P.R.; Thompson, A.K. [National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Lamoreaux, S.K. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States)

2003-06-01T23:59:59.000Z

314

Design, Syntheses and Applications of Fluorescent Dyes  

E-Print Network (OSTI)

New methodologies for the efficient syntheses of 4,4-difluoro-4-bora-3a,4adiaza- s-indacenes (BODIPYs) and rosamines were developed. A serendipitous discovery led to a new reaction which afforded BODIPYs in high yields. Systematic studies of the kinetics and mechanisms of the new reaction were performed. A series of BODIPYs were successfully prepared using the new approach. A simple and efficient synthesis of rosamines with cyclic-amine substituents was devised. These new rosamines showed interesting anti-tumor activities. Several types of novel fluorescent compounds were prepared. Highly fluorescent GFP-chromophore analogs were designed and synthesized. The correlation between the optical properties and the structures was investigated. New pyronin dyes with mesoheteroatom substituents were efficiently prepared. The fluorescence properties of these compounds were highly dependent on the nature of the meso-substituents. A set of BODIPY dyes that fluoresce brightly above 600 nm were made. They were then used as acceptors to prepare water-soluble through-bond energy transfer cassettes. All the cassettes had complete energy transfer and high quantum yields in MeOH. A few also had good fluorescence properties in aqueous media and even on proteins. The through-bond energy transfer cassettes were used to monitor protein-protein interactions. In order to test our hypothesis, an artificial protein interaction system was built by utilizing the biotin/(strept)avidin interactions. Thus Atto425-BSA-biotin, streptavidin-cassette1 and avidin-cassette2 were prepared. The interactions between Atto425-BSA-biotin and cassette labeled (strept)avidin were successfully detected in vitro and in living cells by fluorescence techniques.

Wu, Liangxing

2009-08-01T23:59:59.000Z

315

Ultrabright fluorescent OLEDS using triplet sinks  

DOE Patents (OSTI)

A first device is provided. The first device further comprises an organic light emitting device. The organic light emitting device further comprises an anode, a cathode, and an emissive layer disposed between the anode and the cathode. The emissive layer further comprises an organic host compound, an organic emitting compound capable of fluorescent emission at room temperature, and an organic dopant compound. The triplet energy of the dopant compound is lower than the triplet energy of the host compound. The dopant compound does not strongly absorb the fluorescent emission of the emitting compound.

Zhang, Yifan; Forrest, Stephen R; Thompson, Mark

2013-06-04T23:59:59.000Z

316

DNA sequencing using fluorescence background electroblotting membrane  

DOE Patents (OSTI)

A method for the multiplex sequencing on DNA is disclosed which comprises the electroblotting or specific base terminated DNA fragments, which have been resolved by gel electrophoresis, onto the surface of a neutral non-aromatic polymeric microporous membrane exhibiting low background fluorescence which has been surface modified to contain amino groups. Polypropylene membranes are preferably and the introduction of amino groups is accomplished by subjecting the membrane to radio or microwave frequency plasma discharge in the presence of an aminating agent, preferably ammonia. The membrane, containing physically adsorbed DNA fragments on its surface after the electroblotting, is then treated with crosslinking means such as UV radiation or a glutaraldehyde spray to chemically bind the DNA fragments to the membrane through said smino groups contained on the surface thereof. The DNA fragments chemically bound to the membrane are subjected to hybridization probing with a tagged probe specific to the sequence of the DNA fragments. The tagging may be by either fluorophores or radioisotopes. The tagged probes hybridized to said target DNA fragments are detected and read by laser induced fluorescence detection or autoradiograms. The use of aminated low fluorescent background membranes allows the use of fluorescent detection and reading even when the available amount of DNA to be sequenced is small. The DNA bound to the membrances may be reprobed numerous times.

Caldwell, Karin D. (Salt Lake City, UT); Chu, Tun-Jen (Salt Lake City, UT); Pitt, William G. (Orem, UT)

1992-01-01T23:59:59.000Z

317

DNA sequencing using fluorescence background electroblotting membrane  

DOE Patents (OSTI)

A method for the multiplex sequencing on DNA is disclosed which comprises the electroblotting or specific base terminated DNA fragments, which have been resolved by gel electrophoresis, onto the surface of a neutral non-aromatic polymeric microporous membrane exhibiting low background fluorescence which has been surface modified to contain amino groups. Polypropylene membranes are preferably and the introduction of amino groups is accomplished by subjecting the membrane to radio or microwave frequency plasma discharge in the presence of an aminating agent, preferably ammonia. The membrane, containing physically adsorbed DNA fragments on its surface after the electroblotting, is then treated with crosslinking means such as UV radiation or a glutaraldehyde spray to chemically bind the DNA fragments to the membrane through amino groups contained on the surface. The DNA fragments chemically bound to the membrane are subjected to hybridization probing with a tagged probe specific to the sequence of the DNA fragments. The tagging may be by either fluorophores or radioisotopes. The tagged probes hybridized to the target DNA fragments are detected and read by laser induced fluorescence detection or autoradiograms. The use of aminated low fluorescent background membranes allows the use of fluorescent detection and reading even when the available amount of DNA to be sequenced is small. The DNA bound to the membranes may be reprobed numerous times. No Drawings

Caldwell, K.D.; Chu, T.J.; Pitt, W.G.

1992-05-12T23:59:59.000Z

318

Fluorescent compounds for plastic scintillation applications  

SciTech Connect

Several 2-(2{prime}-hydroxyphenyl)benzothiazole, -benzoxazole, and -benzimidazole derivatives have been prepared. Transmittance, fluorescence, light yield, and decay time characteristics of these compounds have been studied in a polystyrene matrix and evaluated for use in plastic scintillation detectors. Radiation damage studies utilizing a {sup 60}C source have also been performed.

Pla-Dalmau, A.; Bross, A.D.

1994-04-01T23:59:59.000Z

319

Fluorescent Nanoparticles for Radiation DetectionFluorescent Nanoparticles for Radiation Detection  

Researchers at ORNL invented a promising material for more efficient nanoscalescintillators, or radiation detectors. The new material, which can detect most kindsof radiation, consists of fluorescent nanoparticles embedded in a transparent matrix.The ...

320

Advanced Light Sources  

Science Conference Proceedings (OSTI)

In the generation of artificial light using electric lamps, photometric and color performance have been paramount in lamp design, manufacturing, measurement, lighting design, and visual perception. Many designers and researchers have strived to understand how light and color are generated, related, and to improve them. This has stemmed from the development of incandescent lamps, halogen lamps, linear fluorescent lamps, high-intensity discharge (HID) lamps, and compact fluorescent lamps (CFLs) among other...

2008-03-31T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Decontamination Strategy for Large Area and/or Equipment Contaminated with Chemical and Biological Agents using a High Energy Arc Lamp (HEAL)  

Science Conference Proceedings (OSTI)

A strategy for the decontamination of large areas and or equipment contaminated with Biological Warfare Agents (BWAs) and Chemical Warfare Agents (CWAs) was demonstrated using a High Energy Arc Lamp (HEAL) photolysis system. This strategy offers an alternative that is potentially quicker, less hazardous, generates far less waste, and is easier to deploy than those currently fielded by the Department of Defense (DoD). For example, for large frame aircraft the United States Air Force still relies on the combination of weathering (stand alone in environment), air washing (fly aircraft) and finally washing the aircraft with Hot Soapy Water (HSW) in an attempt to remove any remaining contamination. This method is laborious, time consuming (upwards of 12+ hours not including decontamination site preparation), and requires large amounts of water (e.g., 1,600+ gallons for a single large frame aircraft), and generates large amounts of hazardous waste requiring disposal. The efficacy of the HEAL system was demonstrated using diisopropyl methyl phosphonate (DIMP) a G series CWA simulant, and Bacillus globigii (BG) a simulant of Bacillus anthracis. Experiments were designed to simulate the energy flux of a field deployable lamp system that could stand-off 17 meters from a 12m2 target area and uniformly expose a surface at 1360 W/m2. The HEAL system in the absence of a catalyst reduced the amount of B. globigii by five orders of magnitude at a starting concentration of 1.63 x 107 spores. In the case of CWA simulants, the HEAL system in the presence of the catalyst TiO2 effectively degraded DIMP sprayed onto a 100mm diameter Petri dish in 5 minutes.

Schoske, Richard [ORNL; Kennedy, Patrick [ORNL; Duty, Chad E [ORNL; Smith, Rob R [ORNL; Huxford, Theodore J [ORNL; Bonavita, Angelo M [ORNL; Engleman, Greg [ORNL; Vass, Arpad Alexander [ORNL; Griest, Wayne H [ORNL; Ilgner, Ralph H [ORNL; Brown, Gilbert M [ORNL

2009-04-01T23:59:59.000Z

322

Comparison of Segmentation Algorithms For Fluorescence Microscopy Images of Cells  

E-Print Network (OSTI)

Comparison of Segmentation Algorithms For Fluorescence Microscopy Images of Cells Alden A. Dima,1 Mary C. Brady,1 Hai C. Tang,1 Anne L. Plant2 * Abstract The analysis of fluorescence microscopy fluorescence microscopy; k-means cluster; image segmentation; cell edge; bivariate simi- larity index NUMEROUS

Bernal, Javier

323

Product Standards for Fluorescent Lighting (Japan) | Open Energy  

Open Energy Info (EERE)

Product Standards for Fluorescent Lighting (Japan) Product Standards for Fluorescent Lighting (Japan) Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Product Standards for Fluorescent Lighting (Japan) Focus Area: Appliances & Equipment Topics: Policy Impacts Website: www.eccj.or.jp/top_runner/pdf/tr_fluorescent_lights_jul.2009.pdf Equivalent URI: cleanenergysolutions.org/content/product-standards-fluorescent-lightin Language: English Policies: "Deployment Programs,Regulations" is not in the list of possible values (Deployment Programs, Financial Incentives, Regulations) for this property. DeploymentPrograms: Industry Codes & Standards Regulations: Appliance & Equipment Standards and Required Labeling This Energy Conservation Center Japan (ECCJ) document was created as a

324

Browse wiki | Open Energy Information  

Open Energy Info (EERE)

of energy-saving Compact Fluorescent Light Bulbs + , solar-powered lights + , LED bulbs + , auto lamps and other speciality lamps. + , Nanhai + , Guangdong Province + ,...

325

SSL Roadmap  

NLE Websites -- All DOE Office Websites (Extended Search)

new jobs. For the most part, LEDs will displace point sources such as incandescent lamps (light- bulbs), while OLEDs will displace area sources such as fluorescent lamps. OLEDs...

326

Federal Energy Management Program: Federal Procurement of Energy...  

NLE Websites -- All DOE Office Websites (Extended Search)

industrial luminaires and many types of exterior lighting. ENERGY STAR covers light bulbs, including compact fluorescent lamps and LED lamps, and light fixtures, including a...

327

Catalog of DC Appliances and Power Systems  

E-Print Network (OSTI)

AC LEDs, particularly for lower luminosity bulbs. Efficacy (bulb or tube, a compact fluorescent lamp typically includes an integral ballast, as do HID lamps, and an LED

Garbesi, Karina

2012-01-01T23:59:59.000Z

328

U.S. Energy Information Administration (EIA) - Sector  

Annual Energy Outlook 2012 (EIA)

incandescent bulbs. High-performance incandescent, compact fluorescent, and light-emitting diode (LED) lamps continue to replace low-efficacy incandescent lamps. In 2035,...

329

Solid state laser media driven by remote nuclear powered fluorescence  

DOE Patents (OSTI)

An apparatus is provided for driving a solid state laser by a nuclear powered fluorescence source which is located remote from the fluorescence source. A nuclear reaction produced in a reaction chamber generates fluorescence or photons. The photons are collected from the chamber into a waveguide, such as a fiber optic waveguide. The waveguide transports the photons to the remote laser for exciting the laser.

Prelas, M.A.

1991-01-16T23:59:59.000Z

330

Solid state laser media driven by remote nuclear powered fluorescence  

DOE Patents (OSTI)

An apparatus is provided for driving a solid state laser by a nuclear powered fluorescence source which is located remote from the fluorescence source. A nuclear reaction produced in a reaction chamber generates fluorescence or photons. The photons are collected from the chamber into a waveguide, such as a fiber optic waveguide. The waveguide transports the photons to the remote laser for exciting the laser.

Prelas, Mark A. (Columbia, MO)

1992-01-01T23:59:59.000Z

331

Optical Nanofibers for Manipulating and Probing Single-Atom Fluorescence  

E-Print Network (OSTI)

We demonstrate how optical nanofibers can be used to manipulate and probe single-atom fluorescence. We show that fluorescence photons from a very small number of atoms, average atom number of less than 0.1, around the nanofiber can readily be observed through single-mode optical fiber under resonant laser irradiation. We show also that optical nanofibers enable us to probe the van der Waals interaction between atoms and surface with high precision by observing the fluorescence excitation spectrum.

K. P. Nayak; P. N. Melentiev; M. Morinaga; Fam Le Kien; V. I. Balykin; K. Hakuta

2006-10-17T23:59:59.000Z

332

Laser induced fluorescence of trapped molecular ions  

SciTech Connect

Laser induced fluoresence (LIF) spectra (laser excitation spectra) are conceptually among the most simple spectra to obtain. One need only confine a gaseous sample in a suitable container, direct a laser along one axis of the container, and monitor the sample's fluorescence at a right angle to the laser beam. As the laser wavelength is changed, the changes in fluorescence intensity map the absorption spectrum of the sample. (More precisely, only absorption to states which have a significant radiative decay component are monitored.) For ion spectroscopy, one could benefit in many ways by such an experiment. Most optical ion spectra have been observed by emission techniques, and, aside from the problems of spectral analysis, discharge emission methods often produce the spectra of many species, some of which may be unknown or uncertain. Implicit in the description of LIF given above is certainty as to the chemical identity of the carrier of the spectrum. This article describes a method by which the simplifying aspects of LIF can be extended to molecular ions (albeit with a considerable increase in experimental complexity over that necessary for stable neutral molecules).

Winn, J.S.

1980-10-01T23:59:59.000Z

333

Improved Performance of a Fluorescent Blue Organic Light Emitting ...  

Science Conference Proceedings (OSTI)

Presentation Title, Improved Performance of a Fluorescent Blue Organic Light Emitting Diode with Hole Blocking Materials as Dopants for Transport Layers.

334

Time-resolved fluorescence decay measurements for flowing particles  

DOE Patents (OSTI)

Time-resolved fluorescence decay measurements are disclosed for flowing particles. An apparatus and method for the measurement and analysis of fluorescence for individual cells and particles in flow are described, wherein the rapid measurement capabilities of flow cytometry and the robust measurement and analysis procedures of time-domain fluorescence lifetime spectroscopy are combined. A pulse-modulated CW laser is employed for excitation of the particles. The characteristics and the repetition rate of the excitation pulses can be readily adjusted to accommodate for fluorescence decays having a wide range of lifetimes. 12 figs.

Deka, C.; Steinkamp, J.A.

1999-06-01T23:59:59.000Z

335

ComEd - Business Instant Lighting Discounts Program (Illinois...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

lamps include screw-in CFLs, reduced wattage T8 and T5 linear fluorescents, screw-in LED lamps and LED trim kits and reduced wattage ceramic metal halide lamps. All incentives...

336

Electronic high frequency fluorescent ballasts (past, present and future)  

SciTech Connect

Based upon the years of development and manufacture as well as a documented three and one-half year life test the reliability of the electronic high frequency ballast concept has been established. There are several characteristics that can be used to assess a ballast's performance with respect to cost effectiveness, lamp life and power quality. The higher cost of the electronic ballast is due to the demand exceeding the supply. With more competition in an expanding market the price of ballasts will be significantly reduced. 4 refs.

Verderber, R.R.

1990-03-01T23:59:59.000Z

337

Dynamic fluorescence imaging with molecular agents for cancer detection  

E-Print Network (OSTI)

Non-invasive dynamic optical imaging of small animals requires the development of a novel fluorescence imaging modality. Herein, fluorescence imaging is demonstrated with sub-second camera integration times using agents specifically targeted to disease markers, enabling rapid detection of cancerous regions. The continuous-wave fluorescence imaging acquires data with an intensified or an electronmultiplying charge-coupled device. The work presented in this dissertation (i) assessed dose-dependent uptake using dynamic fluorescence imaging and pharmacokinetic (PK) models, (ii) evaluated disease marker availability in two different xenograft tumors, (iii) compared the impact of autofluorescence in fluorescence imaging of near-infrared (NIR) vs. red light excitable fluorescent contrast agents, (iv) demonstrated dual-wavelength fluorescence imaging of angiogenic vessels and lymphatics associated with a xenograft tumor model, and (v) examined dynamic multi-wavelength, whole-body fluorescence imaging with two different fluorescent contrast agents. PK analysis showed that the uptake of Cy5.5-c(KRGDf) in xenograft tumor regions linearly increased with doses of Cy5.5-c(KRGDf) up to 1.5 nmol/mouse. Above 1.5 nmol/mouse, the uptake did not increase with doses, suggesting receptor saturation. Target to background ratio (TBR) and PK analysis for two different tumor cell lines showed that while Kaposi’s sarcoma (KS1767) exhibited early and rapid uptake of Cy5.5-c(KRGDf), human melanoma tumors (M21) had non-significant TBR differences and early uptake rates similar to the contralateral normal tissue regions. The differences may be due to different compartment location of the target. A comparison of fluorescence imaging with NIR vs. red light excitable fluorescent dyes demonstrates that NIR dyes are associated with less background signal, enabling rapid tumor detection. In contrast, animals injected with red light excitable fluorescent dyes showed high autofluorescence. Dual-wavelength fluorescence images were acquired using a targeted 111In- DTPA-K(IRDye800)-c(KRGDf) to selectively detect tumor angiogenesis and an untargeted Cy5.5 to image lymphatics. After acquiring the experimental data, fluorescence image-guided surgery was performed. Dynamic, multi-wavelength fluorescence imaging was accomplished using a liquid crystal tunable filter (LCTF). Excitation light was used for reflectance images with a LCTF transmitting a shorter wavelength than the peak in the excitation light spectrum. Therefore, images can be dynamically acquired alternating frame by frame between emission and excitation light, which should enable image-guided surgery.

Kwon, Sun Kuk

2006-12-01T23:59:59.000Z

338

Method and apparatus for dimming fluorescent lights  

SciTech Connect

This patent describes a dimmer for fluorescent lights that utilizes the standard ballast associated with the lights, comprising: means for controlling the transmission of the normal line A.C. voltage sine wave to the ballast. This is done so that the A.C. voltage is connected to the ballast for only a selectable period of time during each half cycle of the sine wave and is blocked during the remaining period of each half cycle thereby controlling the power supplied to the discharge portion of the lights to control brightness; and means for applying a high frequency voltage signal to the ballast during at least a portion of the time period when the A.C. signal to the ballast is blocked thereby supplying additional power to the filaments of lights.

Clark, R.

1987-03-17T23:59:59.000Z

339

A transportable fluorescence imagining system for detecting fecal contaminants  

Science Conference Proceedings (OSTI)

Feces are the primary source of many pathogenic organisms that can potentially contaminate agricultural commodities. Feces generally contain chlorophyll a and related compounds due to ingestion of plant materials. Fluorescent responses of these compounds ... Keywords: Fecal contamination, Fluorescence, Food safety, Multispectral imaging

Alan M. Lefcourt; Moon S. Kim; Yud-Ren Chen

2005-07-01T23:59:59.000Z

340

Quantum Optics: Colloidal Fluorescent Semiconductor Nanocrystals (Quantum Dots)  

E-Print Network (OSTI)

U ncorrected Proof Chapter 3 Quantum Optics: Colloidal Fluorescent Semiconductor Nanocrystals (Quantum Dots) in Single-Molecule Detection and Imaging Laurent A. Bentolila, Xavier Michalet, and Shimon quantum dots (QDs), have emerged as new powerful fluorescent probes for in vitro and in vivo biological

Michalet, Xavier

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Assessment of Electrical, Efficiency, and Photometric Performance of Advanced Lighting Sources: Dimmable Advanced Lighting Technolog ies -- Electronic Light-Emitting Diode (LED) Fixtures, Lamps, and Drivers  

Science Conference Proceedings (OSTI)

This EPRI Technical Update addresses the dimming performance of light-emitting diode (LED) lighting. Chapter 1 provides a discussion of basic lighting control, the importance of considering power quality in lighting control, lighting control methods and parameters, and the advantages and future of lighting control. Chapter 2 addresses in more depth the dimming methods used in advanced lighting sources and controls for incandescent, fluorescent, high-intensity discharge (HID) and LED sources. Chapter 3 ad...

2008-12-19T23:59:59.000Z

342

X-Ray Fluorescence (XRF) | Open Energy Information  

Open Energy Info (EERE)

X-Ray Fluorescence (XRF) X-Ray Fluorescence (XRF) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: X-Ray Fluorescence (XRF) Details Activities (0) Areas (0) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Lab Analysis Techniques Exploration Sub Group: Rock Lab Analysis Parent Exploration Technique: Rock Lab Analysis Information Provided by Technique Lithology: Bulk and trace element analysis of rocks, minerals, and sediments. Stratigraphic/Structural: Hydrological: Thermal: Dictionary.png X-Ray Fluorescence (XRF): X-Ray Fluorescence is a lab-based technique used for bulk chemical analysis of rock, mineral, sediment, and fluid samples. The technique depends on the fundamental principles of x-ray interactions with solid materials, similar

343

X-RAY FLUORESCENCE MICROPROBE (XFM) TECHNIQUES AND CAPABILITIES  

NLE Websites -- All DOE Office Websites (Extended Search)

RAY FLUORESCENCE MICROPROBE (XFM) RAY FLUORESCENCE MICROPROBE (XFM) TECHNIQUES AND CAPABILITIES APPLICATIONS WORLD-LEADING MICROFOCUSED EXAFS SPECTROSCOPY * XFM is an optimized three-pole wiggler beamline for the characterization of materials in an "as-is" state that are chemically heterogeneous at the micrometer scale via synchrotron induced X-ray fluorescence. * XFM includes instrumentation for microbeam X-ray fluorescence (µXRF), diffraction (µXRD) and fluorescence computed microtomography (FCMT) . However, it is optimized to provide users state-of-the-art microfocused Extended X-ray Absorption Fine Structure (µEXAFS) spectroscopy between 4 to 20 keV. * XFM will trade-off beam size and flux for sample configuration flexibility. This includes more readily achievable stability

344

SIMULTANEOUS MEASUREMENT OF CIRCULAR DICHROISM AND FLUORESCENCE POLARIZATION ANISOTROPY.  

Science Conference Proceedings (OSTI)

Circular dichroism and fluorescence polarization anisotropy are important tools for characterizing biomolecular systems. Both are used extensively in kinetic experiments involving stopped- or continuous flow systems as well as titrations and steady-state spectroscopy. This paper presents the theory for determining circular dichroism and fluorescence polarization anisotropy simultaneously, thus insuring the two parameters are recorded under exactly the same conditions and at exactly the same time in kinetic experiments. The approach to measuring circular dichroism is that used in almost all conventional dichrographs. Two arrangements for measuring fluorescence polarization anisotropy are described. One uses a single fluorescence detector and signal processing with a lock-in amplifier that is similar to the measurement of circular dichroism. The second approach uses classic ''T'' format detection optics, and thus can be used with conventional photon-counting detection electronics. Simple extensions permit the simultaneous measurement of the absorption and excitation intensity corrected fluorescence intensity.

SUTHERLAND,J.C.

2002-01-19T23:59:59.000Z

345

Covered Product Category: Fluorescent Luminaires | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fluorescent Luminaires Fluorescent Luminaires Covered Product Category: Fluorescent Luminaires October 7, 2013 - 10:52am Addthis Did You Know? Lighting Can Help You Accomplish Other Facility Upgrades and Efficiency Improvements Facilities with significant potential savings in lighting may be able to bundle lighting upgrades with heating, ventilation, air conditioning, and other energy conservation measures into a Utility Energy Service Contract (UESC) or Energy Savings Performance Contract (ESPC). Because of the substantial cost and energy savings potential, replacing lighting can be a key component in financing facility retrofits. The funding portion of the FEMP website offers more information on these and other funding opportunities. FEMP provides acquisition guidance and Federal efficiency requirements

346

Lamps in the Leaping Over  

E-Print Network (OSTI)

‘dusgser gyi nya mo ‘khor lo bskor ba’i rgyud chen po: /rang byung lhun grub ‘bras bu n/ /gdod naslhun grub rang ‘char bas/ /’byung ba lnga la rag ma pas/ /sku gsung thugs la rten mi ‘cha’/ /gsalbyed rig pa’i sgron ma yi s/ /gter khyim phung po gsal byed... / /longs sku dang nisprul pa’i sku/ /chu shel sgron ma’i dpes mtshon kyang/da lta rang la ‘byung ma srid/ /khyung sgoma chag ‘phur mi nus/.14 See TTT 54, p. 504, eigthth chapter of the Byang chub kyi sems rin chen ‘khor lo: /sems nyid rigpa’i sgron ma yis...

Scheidegger, Daniel

2005-01-01T23:59:59.000Z

347

" A Heterodyne Laser-induced Fluorescence Technique to Determine  

NLE Websites -- All DOE Office Websites (Extended Search)

A Heterodyne Laser-induced Fluorescence Technique to Determine A Heterodyne Laser-induced Fluorescence Technique to Determine Simultaneously the Bulk and Time Varying Molecule Velocity Distribution." Inventors Ahmed Diallo, Stephane Mazouffre.The method's primary goal is to determine simultaneously the bulk a The method's primary goal is to determine simultaneously the bulk and the time verying part of the molecule velocity distribution using a heterodyne laser induced fluorescence technique. Used in biology, chemistry and plasma physics laser-induced fluorescence is a well known technique to resolve the bulk velocity distribution of probed molecules and atoms in a medium. The novel approach is aimed at determining not only the bulk distribution, but also the time-varying velocity distribution. The two parts of the velocity distribution are key in the characterization of a

348

Altitude dependence of fluorescence light emission by extensive air showers  

E-Print Network (OSTI)

Fluorescence light is induced by extensive air showers while developing in the Earth's atmosphere. The number of emitted fluorescence photons depends on the conditions of the air and on the energy deposited by the shower particles at every stage of the development. In a previous model calculation, the pressure and temperature dependences of the fluorescence yield have been studied on the basis of kinetic gas theory, assuming temperature-independent molecular collision cross-sections. In this work we investigate the importance of temperature-dependent collision cross-sections and of water vapour quenching on the expected fluorescence yield. The calculations will be applied to simulated air showers while using actual atmospheric profiles to estimate the influence on the reconstructed energy of extensive air showers.

B. Keilhauer; J. Bluemer; R. Engel; H. O. Klages

2008-01-28T23:59:59.000Z

349

Calibration of fluorescence resonance energy transfer in microscopy  

DOE Patents (OSTI)

Imaging hardware, software, calibrants, and methods are provided to visualize and quantitate the amount of Fluorescence Resonance Energy Transfer (FRET) occurring between donor and acceptor molecules in epifluorescence microscopy. The MicroFRET system compensates for overlap among donor, acceptor, and FRET spectra using well characterized fluorescent beads as standards in conjunction with radiometrically calibrated image processing techniques. The MicroFRET system also provides precisely machined epifluorescence cubes to maintain proper image registration as the sample is illuminated at the donor and acceptor excitation wavelengths. Algorithms are described that pseudocolor the image to display pixels exhibiting radiometrically-corrected fluorescence emission from the donor (blue), the acceptor (green) and FRET (red). The method is demonstrated on samples exhibiting FRET between genetically engineered derivatives of the Green Fluorescent Protein (GFP) bound to the surface of Ni chelating beads by histidine-tags.

Youvan, Douglas C. (San Jose, CA); Silva, Christopher M. (Sunnyvale, CA); Bylina, Edward J. (San Jose, CA); Coleman, William J. (Moutain View, CA); Dilworth, Michael R. (Santa Cruz, CA); Yang, Mary M. (San Jose, CA)

2002-09-24T23:59:59.000Z

350

Exploring the mechanome with optical tweezers and single molecule fluorescence  

E-Print Network (OSTI)

The combination of optical tweezers and single molecule fluorescence into an instrument capable of making combined, coincident measurements adds an observable dimension that allows for the examination of the localized ...

Brau, Ricardo R. (Ricardo Rafael), 1979-

2008-01-01T23:59:59.000Z

351

Fluorescence Enhancement of White-Light Cadmium Selenide Nanocrystals.  

E-Print Network (OSTI)

??Advances are being made in lighting technology, as incandescent and fluorescent light bulbs become less efficient compared to solid-state lighting devices, especially light-emitting diodes (LEDs).… (more)

Rosson, Teresa Ellen

2011-01-01T23:59:59.000Z

352

THE HISTORY AND TECHNICAL EVOLUTION OF HIGH FREQUENCY FLUORESCENT LIGHTING  

E-Print Network (OSTI)

Dec. 1953. "Hi-Volt-Cycle Lighting ~ Launched i n a Hi-Wide2, F e b r u a r y , 19 53. "Lighting Your Plant with Highg h Frequency Fluorescent Lighting John H. Campbell December

Campbell, John H.

2011-01-01T23:59:59.000Z

353

A review of indocyanine green fluorescent imaging in surgery  

Science Conference Proceedings (OSTI)

The purpose of this paper is to give an overview of the recent surgical intraoperational applications of indocyanine green fluorescence imaging methods, the basics of the technology, and instrumentation used. Well over 200 papers describing this technique ...

Jarmo T. Alander, Ilkka Kaartinen, Aki Laakso, Tommi Pätilä, Thomas Spillmann, Valery V. Tuchin, Maarit Venermo, Petri Välisuo

2012-01-01T23:59:59.000Z

354

Lighting the Way with Compact Fluorescent Lighting | Department...  

NLE Websites -- All DOE Office Websites (Extended Search)

and compact fluorescent lights. And I've already purchased a few of the new light emitting diode (LED) solid-state lighting lights-but that's the topic of a future blog. Stay...

355

Assessment of Nuclear Resonance Fluorescence for Spent Nuclear Fuel Assay  

E-Print Network (OSTI)

Fluorescence for Spent Nuclear Fuel Assay Brian J. Quiter ?of Pu isotopes in spent nuclear fuel (SNF). Given the lowU and 239 Pu in spent nuclear fuel using NRF. II. PERFORMING

Quiter, Brian

2012-01-01T23:59:59.000Z

356

Large core polymer optical backplanes for fluorescence detection  

E-Print Network (OSTI)

Fluorescence based sensors are used for determining environmental parameters such as dissolved oxygen or pH in biological systems without disturbing a biological system's equilibrium. Recently, there has been a drive to ...

Lee, Kevin Shao-Kwan

2006-01-01T23:59:59.000Z

357

Federal Energy Management Program: Energy Cost Calculator for Compact  

NLE Websites -- All DOE Office Websites (Extended Search)

Compact Fluorescent Lamps to someone by E-mail Compact Fluorescent Lamps to someone by E-mail Share Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Facebook Tweet about Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Twitter Bookmark Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Google Bookmark Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Delicious Rank Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on Digg Find More places to share Federal Energy Management Program: Energy Cost Calculator for Compact Fluorescent Lamps on AddThis.com... Energy-Efficient Products Federal Requirements Covered Product Categories

358

Energy Efficiency Standards and Labels in North America: Opportunities for Harmonization  

E-Print Network (OSTI)

L mc ,S m L ve ** ,S m Dishwashers L mc ,L ve ,S m L mc ,LClothes washers Clothes washers and dryers DishwashersDishwashers Fluorescent lamp ballasts Fluorescent lamp

Wiel, Stephen

2008-01-01T23:59:59.000Z

359

Baltimore Gas & Electric Company (Electric) - Commercial Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lamps: 25 - 30 Lighting Occupancy Sensors: 25-75unit T8T5 Fluorescent Lamp-Ballast: 15-65fixture Fluorescent High-Bay Fixtures: 40 - 85fixture Hard-Wired CFL:...

360

Demonstration of Recessed Downlight Technologies: Power and Illumination Assessment  

SciTech Connect

Solid state lighting (SSL), specifically light-emitting diodes (LED), has been advancing at a rapid pace, and there are presently multiple products available that serve as direct replacements for traditional luminaires. In this demonstration, conventional recessed lights in a conference room were used to compare conventional incandescent A-lamps, incandescent reflector R-lamps, dimming compact fluorescent lamps (CFL), to an LED replacement product. The primary focus during the study was on light delivered to the task plane as provided by the power required by the lighting system. Vertical illuminance, dimming range, and color shift are also important indicators of lighting quality and are discussed in the report. The results clearly showed that LEDs, with dimming-capable drivers, are much more efficient than incandescent and CFLs. Further, LEDs provide much smoother and consistent dimming than dimmable CFLs. On the potential negative side, it is important that the dimming switch be identified as compatible with the LED driver. A wide variety of dimmer switches are capable of dimming LEDs down to 15% of full light output, while select others can be capable of dimming LEDs down to 5%. In addition, LEDs can be intensive light sources, which can result in uncomfortable glare in some applications and to some occupants. Higher ceiling (9-foot or greater) or non-specular reflectors can act to alleviate the potential for glare.

Parker, Steven A.; Beeson, Tracy A.

2009-11-20T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

NIST Highlight about spectrally tunable lighting facility  

Science Conference Proceedings (OSTI)

... white light produced by fluorescent lamps? Which spectral combination gives the best color quality and energy efficiency? ...

2012-10-02T23:59:59.000Z

362

Characteristics and Applications of Copper Stamp Sand  

Science Conference Proceedings (OSTI)

The chemical, physical properties and antimicrobial activity of stamp sand were investigated, ... Characterization of Fluorescent Lamp Glass Waste Powders for ...

363

New and Underutilized Technology: Interior LED/Solid State Lighting |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interior LED/Solid State Lighting Interior LED/Solid State Lighting New and Underutilized Technology: Interior LED/Solid State Lighting October 4, 2013 - 4:53pm Addthis The following information outlines key deployment considerations for interior LED/solid state lighting within the Federal sector. Benefits Interior LED retrofits are currently viable for down lights, track lighting, sconces, and both line and low voltage task lighting. Replacements for incandescent A-lamps have also been improving rapidly. Replacements for fluorescent tube lighting may be viable for high-cost maintenance areas. Application Interior LED/solid state lighting is a rapidly improving technology currently most applicable for down lights, track lights, task lighting, accenting, high ceiling, and high cost maintenance areas.

364

Cyanine-based probe\\tag-peptide pair fluorescence protein imaging and fluorescence protein imaging methods  

DOE Patents (OSTI)

A molecular probe comprises two arsenic atoms and at least one cyanine based moiety. A method of producing a molecular probe includes providing a molecule having a first formula, treating the molecule with HgOAc, and subsequently transmetallizing with AsCl.sub.3. The As is liganded to ethanedithiol to produce a probe having a second formula. A method of labeling a peptide includes providing a peptide comprising a tag sequence and contacting the peptide with a biarsenical molecular probe. A complex is formed comprising the tag sequence and the molecular probe. A method of studying a peptide includes providing a mixture containing a peptide comprising a peptide tag sequence, adding a biarsenical probe to the mixture, and monitoring the fluorescence of the mixture.

Mayer-Cumblidge, M. Uljana; Cao, Haishi

2013-01-15T23:59:59.000Z

365

Interference in the resonance fluorescence of two incoherently coupled transitions  

E-Print Network (OSTI)

The fluorescence light emitted by a 4-level system in $J=1/2$ to $J=1/2$ configuration driven by a monochromatic laser field and in an external magnetic field is studied. We show that the spectrum of resonance fluorescence emitted on the $\\pi$ transitions shows a signature of spontaneously generated interference effects. The degree of interference in the fluorescence spectrum can be controlled by means of the external magnetic field, provided that the Land\\'e g-factors of the excited and the ground state doublet are different. For a suitably chosen magnetic field strength, the relative weight of the Rayleigh line can be completely suppressed, even for low intensities of the coherent driving field. The incoherent fluorescence spectrum emitted on the $\\pi$ transitions exhibits a very narrow peak whose width and weight depends on the magnetic field strength. We demonstrate that the spectrum of resonance fluorescence emitted on the $\\sigma$ transitions show an indirect signature of interference. A measurement of the relative peak heights in the spectrum from the $\\sigma$ transitions allows to determine the branching ratio of the spontaneous decay of each excited state into the $\\sigma$ channel.

Martin Kiffner; Joerg Evers; Christoph H. Keitel

2006-03-09T23:59:59.000Z

366

Nuclear Resonance Fluorescence for Safeguards Applications  

SciTech Connect

In nuclear resonance fluorescence (NRF) measurements, resonances are excited by an external photon beam leading to the emission of {gamma} rays with specific energies that are characteristic of the emitting isotope. The promise of NRF as a non-destructive analysis technique (NDA) in safeguards applications lies in its potential to directly quantify a specific isotope in an assay target without the need for unfolding the combined responses of several fissile isotopes as often required by other NDA methods. The use of NRF for detection of sensitive nuclear materials and other contraband has been researched in the past. In the safeguards applications considered here one has to go beyond mere detection and precisely quantify the isotopic content, a challenge that is discussed throughout this report. Basic NRF measurement methods, instrumentation, and the analytical calculation of NRF signal strengths are described in Section 2. Well understood modeling and simulation tools are needed for assessing the potential of NRF for safeguards and for designing measurement systems. All our simulations were performed with the radiation transport code MCNPX, a code that is widely used in the safeguards community. Our initial studies showed that MCNPX grossly underestimated the elastically scattered background at backwards angles due to an incorrect treatment of Rayleigh scattering. While new, corrected calculations based on ENDF form factors showed much better agreement with experimental data for the elastic scattering of photons on an uranium target, the elastic backscatter is still not rigorously treated. Photonuclear scattering processes (nuclear Thomson, Delbruck and Giant Dipole Resonance scattering), which are expected to play an important role at higher energies, are not yet included. These missing elastic scattering contributions were studied and their importance evaluated evaluated against data found in the literature as discussed in Section 3. A transmission experiment was performed in September 2009 to test and demonstrate the applicability of the method to the quantitative measurement of an isotope of interest embedded in a thick target. The experiment, data analysis, and results are described in Section 4. The broad goal of our NRF studies is to assess the potential of the technique in safeguards applications. Three examples are analyzed in Section 5: the isotopic assay of spent nuclear fuel (SNF), the measurement of {sup 235}U enrichment in UF{sub 6} cylinders, and the determination of {sup 239}Pu in mixed oxide (MOX) fuel. The study of NRF for the assay of SNF assemblies was supported by the Next Generation Safeguards Initiative (NGSI) of the U.S. Department of Energy as part of a large multi-lab/university effort to quantify the plutonium (Pu) mass in spent nuclear fuel assemblies and to detect the diversion of pins with non-destructive assay (NDA) methods. NRF is one of 14 NDA techniques being researched. The methodology for performing and analyzing quantitative NRF measurements was developed for determining Pu mass in SNF and is extensively discussed in this report. The same methodology was applied to the assessment of NRF for the measurement of {sup 235}U enrichment and the determination of {sup 239}Pu in MOX fuel. The analysis centers on determining suitable NRF measurement methods, measurement capabilities that could be realized with currently available instrumentation, and photon source and detector requirements for achieving useful NDA capabilities.

Ludewigt, Bernhard A; Quiter, Brian J; Ambers, Scott D

2011-02-04T23:59:59.000Z

367

EA-1664: Final Environmental Assessment | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

64: Final Environmental Assessment 64: Final Environmental Assessment EA-1664: Final Environmental Assessment 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps The U.S. Department of Energy has determined that the adoption of energy conservation standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps as described in the final rule titled the "energy Conservation Program: Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector lamps," would not be a major federal action significantly affecting the quality of the human environment. Environmental Assessment for 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps,

368

A Bright Idea: New Efficiency Standards for Incandescent and Fluorescent  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

A Bright Idea: New Efficiency Standards for Incandescent and A Bright Idea: New Efficiency Standards for Incandescent and Fluorescent Lights A Bright Idea: New Efficiency Standards for Incandescent and Fluorescent Lights July 21, 2009 - 5:18pm Addthis John Lippert Pretty soon, lighting is going to get a lot more efficient. New standards for incandescent reflector bulbs, general purpose fluorescent bulbs, and regular incandescent bulbs are going into effect beginning in approximately three years. You may be curious about how these standards will affect the most popular types of incandescent bulbs we've all used for so long: the common non-reflector 40-watt, 60-watt, 75-watt, and 100-watt bulbs. The Energy Independence and Security Act of 2007 (also known as EISA) requires that these incandescent bulbs use 30% less energy than today's

369

Laser-induced differential normalized fluorescence method for cancer diagnosis  

SciTech Connect

An apparatus and method for cancer diagnosis are disclosed. The diagnostic method includes the steps of irradiating a tissue sample with monochromatic excitation light, producing a laser-induced fluorescence spectrum from emission radiation generated by interaction of the excitation light with the tissue sample, and dividing the intensity at each wavelength of the laser-induced fluorescence spectrum by the integrated area under the laser-induced fluorescence spectrum to produce a normalized spectrum. A mathematical difference between the normalized spectrum and an average value of a reference set of normalized spectra which correspond to normal tissues is calculated, which provides for amplifying small changes in weak signals from malignant tissues for improved analysis. The calculated differential normalized spectrum is correlated to a specific condition of a tissue sample.

Vo-Dinh, Tuan (Knoxville, TN); Panjehpour, Masoud (Knoxville, TN); Overholt, Bergein F. (Knoxville, TN)

1996-01-01T23:59:59.000Z

370

BIOCOMPATIBLE FLUORESCENT MICROSPHERES: SAFE PARTICLES FOR MATERIAL PENETRATION STUDIES  

SciTech Connect

Biocompatible polymers with hydrolyzable chemical bonds have been used to produce safe, non-toxic fluorescent microspheres for material penetration studies. The selection of polymeric materials depends on both biocompatibility and processability, with tailored fluorescent properties depending on specific applications. Microspheres are composed of USFDA-approved biodegradable polymers and non-toxic fluorophores and are therefore suitable for tests where human exposure is possible. Micropheres were produced which contain unique fluorophores to enable discrimination from background aerosol particles. Characteristics that affect dispersion and adhesion can be modified depending on use. Several different microsphere preparation methods are possible, including the use of a vibrating orifice aerosol generator (VOAG), a Sono-Tek atomizer, an emulsion technique, and inkjet printhead. Applications for the fluorescent microspheres include challenges for biodefense system testing, calibrants for biofluorescence sensors, and particles for air dispersion model validation studies.

Farquar, G; Leif, R

2009-07-15T23:59:59.000Z

371

Fluorescent single walled nanotube/silica composite materials  

DOE Patents (OSTI)

Fluorescent composites of surfactant-wrapped single-walled carbon nanotubes (SWNTs) were prepared by exposing suspensions of surfactant-wrapped carbon nanotubes to tetramethylorthosilicate (TMOS) vapor. Sodium deoxycholate (DOC) and sodium dodecylsulphate (SDS) were the surfactants. No loss in emission intensity was observed when the suspension of DOC-wrapped SWNTs were exposed to the TMOS vapors, but about a 50% decrease in the emission signal was observed from the SDS-wrapped SWNTs nanotubes. The decrease in emission was minimal by buffering the SDS/SWNT suspension prior to forming the composite. Fluorescent xerogels were prepared by adding glycerol to the SWNT suspensions prior to TMOS vapor exposure, followed by drying the gels. Fluorescent aerogels were prepared by replacing water in the gels with methanol and then exposing them to supercritical fluid drying conditions. The aerogels can be used for gas sensing.

Dattelbaum, Andrew M.; Gupta, Gautam; Duque, Juan G.; Doorn, Stephen K.; Hamilton, Christopher E.; DeFriend Obrey, Kimberly A.

2013-03-12T23:59:59.000Z

372

Time-resolved Hyperspectral Fluorescence Spectroscopy using Frequency Modulated Excitation  

SciTech Connect

An intensity-modulated excitation light source is used together with a micro channel plate intensified CCD (ICCD) detector gated at a slightly different frequency to generate a beat frequency from a fluorescent sample. The addition of a spectrograph produces a hyperspectral time-resolved data product where the resulting beat frequency is detected with a low frame rate camera. Measuring the beat frequency of the spectrum as a function of time allows separation of the excited fluorescence from ambient constant light sources. The excitation and detector repetition rates are varied over a range of discrete frequencies, and the phase shift of the beat wave maps out the emission decay rate(s).

,; Neill, M

2012-07-01T23:59:59.000Z

373

A versatile detector for total fluorescence and electron yield experiments  

Science Conference Proceedings (OSTI)

The combination of a non-coated silicon photodiode with electron repelling meshes makes a versatile detector for total fluorescence yield and electron yield techniques highly suitable for x-ray absorption spectroscopy. In particular, a copper mesh with a bias voltage allows to suppress or transmit the electron yield signal. The performance of this detection scheme has been characterized by near edge x-ray absorption fine structure studies of thermal oxidized silicon and sapphire. The results show that the new detector probes both electron yield and for a bias voltage exceeding the maximum photon energy the total fluorescence yield.

Thielemann, N. [Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, Albert-Einstein-Str. 15, 12489 Berlin (Germany); Institut fuer Physik, Humboldt-Universitaet zu Berlin, Newtonstrasse 15, 12489 Berlin (Germany); Hoffmann, P. [Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, Albert-Einstein-Str. 15, 12489 Berlin (Germany); Foehlisch, A. [Institute for Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, Albert-Einstein-Str. 15, 12489 Berlin (Germany); Institut fuer Physik und Astronomie, Universitaet Potsdam, Karl-Liebknecht-Strasse 24-25, 14476 Potsdam (Germany)

2012-09-15T23:59:59.000Z

374

Digital optical phase conjugation of fluorescence in turbid tissue  

SciTech Connect

We demonstrate a method for phase conjugating fluorescence. Our method, called reference free digital optical phase conjugation, can conjugate extremely weak, incoherent optical signals. It was used to phase conjugate fluorescent light originating from a bead covered with 0.5 mm of light-scattering tissue. The phase conjugated beam refocuses onto the bead and causes a local increase of over two orders of magnitude in the light intensity. Potential applications are in imaging, optical trapping, and targeted photochemical activation inside turbid tissue.

Vellekoop, Ivo M.; Cui Meng; Yang Changhuei [Department of Electrical Engineering, California Institute of Technology, Pasadena, California (United States)

2012-08-20T23:59:59.000Z

375

Fluorescence Axial Localization with Nanometer Accuracy and Precision  

SciTech Connect

We describe a new technique, standing wave axial nanometry (SWAN), to image the axial location of a single nanoscale fluorescent object with sub-nanometer accuracy and 3.7 nm precision. A standing wave, generated by positioning an atomic force microscope tip over a focused laser beam, is used to excite fluorescence; axial position is determined from the phase of the emission intensity. We use SWAN to measure the orientation of single DNA molecules of different lengths, grafted on surfaces with different functionalities.

Li, Hui; Yen, Chi-Fu; Sivasankar, Sanjeevi

2012-06-15T23:59:59.000Z

376

Combination of fluorescence imaging and local spectrophotometry in fluorescence diagnostics of early cancer of larynx and bronchi  

SciTech Connect

The results of comparative studies of autofluorescence and 5-ALA-induced fluorescence of protoporphyrin IX, used in the diagnostics of early cancer of larynx and bronchi, are presented. The autofluorescence and 5-ALA-induced fluorescence images of larynx and bronchial tissues are analysed during the endoscopic study. The method of local spectrophotometry is used to verify findings obtained from fluorescence images. It is shown that such a combined approach can be efficiently used to improve the diagnostics of precancer and early cancer, to detect a primary multiple tumours, as well as for the diagnostics of a residual tumour or an early recurrence after the endoscopic, surgery or X-ray treatment. The developed approach allows one to minimise the number of false-positive results and to reduce the number of biopsies, which are commonly used in the white-light bronchoscopy search for occult cancerous loci. (laser biology and medicine)

Sokolov, Vladimir V; Filonenko, E V; Telegina, L V [P.A. Hertsen Moscow Research Oncological Institute, Moscow (Russian Federation); Boulgakova, N N; Smirnov, V V [A.M. Prokhorov General Physics Institute, Russian Academy of Sciences, Moscow (Russian Federation)

2002-11-30T23:59:59.000Z

377

Automated hybridization/imaging device for fluorescent multiplex DNA sequencing  

DOE Patents (OSTI)

A method is disclosed for automated multiplex sequencing of DNA with an integrated automated imaging hybridization chamber system. This system comprises an hybridization chamber device for mounting a membrane containing size-fractionated multiplex sequencing reaction products, apparatus for fluid delivery to the chamber device, imaging apparatus for light delivery to the membrane and image recording of fluorescence emanating from the membrane while in the chamber device, and programmable controller apparatus for controlling operation of the system. The multiplex reaction products are hybridized with a probe, the enzyme (such as alkaline phosphatase) is bound to a binding moiety on the probe, and a fluorogenic substrate (such as a benzothiazole derivative) is introduced into the chamber device by the fluid delivery apparatus. The enzyme converts the fluorogenic substrate into a fluorescent product which, when illuminated in the chamber device with a beam of light from the imaging apparatus, excites fluorescence of the fluorescent product to produce a pattern of hybridization. The pattern of hybridization is imaged by a CCD camera component of the imaging apparatus to obtain a series of digital signals. These signals are converted by the controller apparatus into a string of nucleotides corresponding to the nucleotide sequence an automated sequence reader. The method and apparatus are also applicable to other membrane-based applications such as colony and plaque hybridization and Southern, Northern, and Western blots. 9 figs.

Weiss, R.B.; Kimball, A.W.; Gesteland, R.F.; Ferguson, F.M.; Dunn, D.M.; Di Sera, L.J.; Cherry, J.L.

1995-11-28T23:59:59.000Z

378

Automated hybridization/imaging device for fluorescent multiplex DNA sequencing  

DOE Patents (OSTI)

A method is disclosed for automated multiplex sequencing of DNA with an integrated automated imaging hybridization chamber system. This system comprises an hybridization chamber device for mounting a membrane containing size-fractionated multiplex sequencing reaction products, apparatus for fluid delivery to the chamber device, imaging apparatus for light delivery to the membrane and image recording of fluorescence emanating from the membrane while in the chamber device, and programmable controller apparatus for controlling operation of the system. The multiplex reaction products are hybridized with a probe, then an enzyme (such as alkaline phosphatase) is bound to a binding moiety on the probe, and a fluorogenic substrate (such as a benzothiazole derivative) is introduced into the chamber device by the fluid delivery apparatus. The enzyme converts the fluorogenic substrate into a fluorescent product which, when illuminated in the chamber device with a beam of light from the imaging apparatus, excites fluorescence of the fluorescent product to produce a pattern of hybridization. The pattern of hybridization is imaged by a CCD camera component of the imaging apparatus to obtain a series of digital signals. These signals are converted by the controller apparatus into a string of nucleotides corresponding to the nucleotide sequence an automated sequence reader. The method and apparatus are also applicable to other membrane-based applications such as colony and plaque hybridization and Southern, Northern, and Western blots.

Weiss, Robert B. (Salt Lake City, UT); Kimball, Alvin W. (Salt Lake City, UT); Gesteland, Raymond F. (Salt Lake City, UT); Ferguson, F. Mark (Salt Lake City, UT); Dunn, Diane M. (West Valley City, UT); Di Sera, Leonard J. (Salt Lake City, UT); Cherry, Joshua L. (Salt Lake City, UT)

1995-01-01T23:59:59.000Z

379

Restoration of X-ray fluorescence images of hidden paintings  

Science Conference Proceedings (OSTI)

This paper describes our methods for repairing and restoring images of hidden paintings (paintings that have been painted over and are now covered by a new surface painting) that have been obtained via noninvasive X-ray fluorescence imaging of their ... Keywords: Art restoration, Artifact correction, Image restoration, Underdetermined source separation

Anila Anitha; Andrei Brasoveanu; Marco Duarte; Shannon Hughes; Ingrid Daubechies; Joris Dik; Koen Janssens; Matthias Alfeld

2013-03-01T23:59:59.000Z

380

Distinguishability of Biological Material Using Ultraviolet Multi-Spectral Fluorescence  

SciTech Connect

Recent interest in the detection and analysis of biological samples by spectroscopic methods has led to questions concerning the degree of distinguishability and biological variability of the ultraviolet (W) fluorescent spectra from such complex samples. We show that the degree of distinguishability of such spectra is readily determined numerically.

Gray, P.C.; Heinen, R.J.; Rigdon, L.D.; Rosenthal, S.E.; Shokair, I.R.; Siragusa, G.R.; Tisone, G.C.; Wagner, J.S.

1998-10-14T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Fluorescence photon migration by the boundary element method  

Science Conference Proceedings (OSTI)

The use of the boundary element method (BEM) is explored as an alternative to the finite element method (FEM) solution methodology for the elliptic equations used to model the generation and transport of fluorescent light in highly scattering media, without the need for an internal volume mesh. The method is appropriate for domains where it is reasonable to assume the fluorescent properties are regionally homogeneous, such as when using highly specific molecularly targeted fluorescent contrast agents in biological tissues. In comparison to analytical results on a homogeneous sphere, BEM predictions of complex emission fluence are shown to be more accurate and stable than those of the FEM. Emission fluence predictions made with the BEM using a 708-node mesh, with roughly double the inter-node spacing of boundary nodes as in a 6956-node FEM mesh, match experimental frequency-domain fluorescence emission measurements acquired on a 1087 cm{sup 3} breast-mimicking phantom at least as well as those of the FEM, but require only 1/8 to 1/2 the computation time.

Fedele, Francesco [Department of Civil and Environmental Engineering, University of Vermont, Burlington, VT 05405 (United States); Eppstein, Margaret J. [Department of Computer Science, University of Vermont, Burlington, VT 05405 (United States)]. E-mail: maggie.eppstein@uvm.edu; Laible, Jeffrey P. [Department of Civil and Environmental Engineering, University of Vermont, Burlington, VT 05405 (United States); Godavarty, Anuradha [Photon Migration Laboratories, Department of Chemistry, Texas A and M University, College Station, TX 77842-3012 (United States); Sevick-Muraca, Eva M. [Photon Migration Laboratories, Department of Chemistry, Texas A and M University, College Station, TX 77842-3012 (United States)

2005-11-20T23:59:59.000Z

382

Examining 239Pu and 240Pu Nuclear Resonance Fluorescence Measurements on Spent Fuel for Nuclear Safeguards  

E-Print Network (OSTI)

resonance fluorescence in 240 Pu,” Submitted to Phys. Rev.near 2 MeV in 235 U and 239 Pu,” Phys. Rev. C 041601(R) (Examining Pu and Pu Nuclear Resonance Fluorescence

Quiter, Brian

2013-01-01T23:59:59.000Z

383

Have You Switched to Compact Fluorescent Lights? Why or Why Not...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Switched to Compact Fluorescent Lights? Why or Why Not? Have You Switched to Compact Fluorescent Lights? Why or Why Not? May 1, 2009 - 1:52pm Addthis On Tuesday, John wrote about...

384

DNA complexes with dyes designed for energy transfer as fluorescent markers  

DOE Patents (OSTI)

Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated. 4 figs.

Glazer, A.N.; Benson, S.C.

1997-07-08T23:59:59.000Z

385

DNA complexes with dyes designed for energy transfer as fluorescent markers  

DOE Patents (OSTI)

Heteromultimeric fluorophores are provided for binding to DNA, which allow for the detection of DNA in electrical separations and preparation of probes having high-fluorescent efficiencies and large Stokes shifts. In addition, by appropriate choice of fluorescent molecules, one can use a single narrow wavelength band excitation light source, while obtaining fluorescent emissions having sufficient separation to be readily discriminated. 4 figs.

Glazer, A.M.; Benson, S.C.

1998-06-16T23:59:59.000Z

386

Arnold Schwarzenegger LIGHTING RESEARCH PROGRAM  

E-Print Network (OSTI)

fluorescent task lamp. The prototype used commercially available materials: 1watt light emitting diodes to the mounting board. Development of LightEmitting Diode Task Lamp using Advanced Technologies: Prototype 2 lightemitting diode task lamp. The problem of developing an energy efficient light emitting diode task lamp

387

Biological detection and tagging using tailorable, reactive, highly fluorescent chemosensors.  

Science Conference Proceedings (OSTI)

This program was focused on the development of a fluorogenic chemosensor family that could tuned for reaction with electrophilic (e.g. chemical species, toxins) and nucleophilic (e.g. proteins and other biological molecules) species. Our chemosensor approach utilized the fluorescent properties of well-known berberine-type alkaloids. In situ chemosensor reaction with a target species transformed two out-of-plane, weakly conjugated, short-wavelength chromophores into one rigid, planar, conjugated, chromophore with strong long wavelength fluorescence (530-560 nm,) and large Stokes shift (100-180 nm). The chemosensor was activated with an isourea group which allowed for reaction with carboxylic acid moieties found in amino acids.

Shepodd, Timothy J.; Zifer, Thomas; McElhanon, James Ross; Rahn, Larry A.

2006-11-01T23:59:59.000Z

388

COMBINED FLUORESCENT AND GOLD PROBES FOR MICROSCOPIC AND MORPHOLOGICAL INVESTIGATIONS.  

SciTech Connect

Nanogold{reg_sign}, a gold cluster with a core of gold atoms 1.4 nm in diameter, has proven to be a superior probe label for electron microscopy (EM), giving both higher labeling density and improved access to previously hindered or restricted antigens. It may be visualized by autometallography (AMG) for use in light microscopy (LM): silver-and gold-amplified Nanogold detection has proven to be one of the most sensitive methods available for the detection of low copy number targets such as viral DNA in cells and tissue specimens. AMG enhancement has also made Nanogold an effective detection label in blots and gels. The following protocols will be described: Labeling of nuclear components in cells. Protocol for in situ hybridization and detection with fluorescein-Nanogold--or Cy3{trademark}-Nanogold-labeled streptavidin. Nanogold is an inert molecule, and generally does not interact with biological molecules unless a specific chemical reactivity is introduced into the molecule. Conjugates are prepared using site-specific chemical conjugation through reactive chemical functionalities introduced during Nanogold preparation, which allows the gold label to be attached to a specific site on the conjugate biomolecule. For example, a maleimido-Nanogold derivative, which is specific for thiol binding, is frequently attached to the hinge region of an antibody at a unique thiol site generated by selective reduction of a hinge disulfide. This site is remote from the antigen combining region, and the Nanogold, therefore, does not compromise target binding. Nanogold may also be prepared with specific reactivity towards amines or other unique chemical groups. This mode of attachment enables the preparation of probes labeled with both Nanogold and fluorescent labels. Different chemical reactivities are used to attach the Nanogold and the fluorescent groups to different sites in the conjugate biomolecule, as shown in Figure 7.1. In this manner, the two labels are spaced sufficiently far apart that fluorescent resonance energy transfer does not quench the fluorescent signal, and the probes may be used to label specimens for fluorescent and EM observation in a single staining procedure. This reduces the complexity of the staining procedure, allowing less specimen perturbation, and also enables a higher degree of correlation between the fluorescence and EM localization of the target, thus increasing the usefulness of the complementary data sets. Since gold and fluorescent-labeled probes are often used at different concentrations under different conditions, optimum procedures for the use of fluorescent and gold probes may entail some degree of compromise between the most appropriate conditions for the two types of probes. However, the chemical stability of the Nanogold label means that it is generally stable to a wide range of use conditions, and the following protocols have been found to be effective for labeling specimens with combined fluorescein and Nanogold-labeled antibody Fab' probes and with combined Cy3 and Nanogold-labeled streptavidin.

POWELL,R.D.HAINFELD,J.F.

2002-04-17T23:59:59.000Z

389

Studying DNA translocation in nanocapillaries using single molecule fluorescence  

E-Print Network (OSTI)

We demonstrate simultaneous measurements of DNA translocation into glass nanopores using ionic current detection and fluorescent imaging. We verify the correspondence between the passage of a single DNA molecule through the nanopore and the accompanying characteristic ionic current blockage. By tracking the motion of individual DNA molecules in the nanocapillary perpendicular to the optical axis and using a model, we can extract an effective mobility constant for DNA in our geometry under high electric fields.

Thacker, Vivek V; Hernández-Ainsa, Silvia; Bell, Nicholas A W; Keyser, Ulrich F; 10.1063/1.4768929

2013-01-01T23:59:59.000Z

390

Glovebox characterization and barrier integrity testing using fluorescent powder  

SciTech Connect

This paper presents a method for characterizing the spread of contamination and testing the barrier integrity of a new glovebox during material transfer operations and glove change-outs using fluorescent powder. Argonne National Laboratory-West has performed this test on several new gloveboxes prior to putting them into service. The test is performed after the glovebox has been leak tested and all systems have been verified to be operational. The purpose of the test is to show that bag-in/bag-out operations and glove change-outs can be accomplished without spreading the actual contaminated material to non-contaminated areas. The characterization test also provides information as to where contamination might be expected to build-up during actual operations. The fluorescent powder is used because it is easily detectable using an ultra-violet light and disperses in a similar fashion to radioactive material. The characterization and barrier integrity test of a glovebox using fluorescent powder provides a visual method of determining areas of potential contamination accumulation and helps evaluate the ability to perform clean transfer operations and glove change-outs.

Wahlquist, D.R. [Argonne National Lab., Idaho Falls, ID (United States). Technology Development Div.

1996-07-01T23:59:59.000Z

391

Impurity studies in fusion devices using laser-fluorescence spectroscopy  

DOE Green Energy (OSTI)

Resonance fluorescence excitation of neutral atoms using tunable radiation from dye lasers offers a number of unique advantages for impurity studies in fusion devices. Using this technique, it is possible to perform local time-resolved measurements of the densities and velocity distributions of metallic impurities in fusion devices without disturbing the plasma. Velocities are measured by monitoring the fluorescence intensity while tuning narrow bandwidth laser radiation through the Doppler-broadened absorption spectrum of the transition. The knowledge of the velocity distribution of neutral impurities is particularly useful for the determination of impurity introduction mechanisms. The laser fluorescence technique will be described in terms of its application to metallic impurities in fusion devices and related laboratory experiments. Particular attention will be given to recent results from the ISX-B tokamak using pulsed dye lasers where detection sensitivities for neutral Fe of 10/sup 6/ atoms/cm/sup 3/ with a velocity resolution of 600 m/s (0.1 eV) have been achieved.

Husinsky, W.R.

1981-04-01T23:59:59.000Z

392

Remediation plan for fluorescent light fixtures containing polychlorinated biphenyls (PCBs)  

SciTech Connect

This report describes the remedial action to achieve compliance with 29 CFR 1910 Occupational Safety and Health Administration (OSHA) requirements of fluorescent light fixtures containing PCBs at K-25 site. This remedial action is called the Remediation Plan for Fluorescent Light Fixtures Containing PCBs at the K-25 Site (The Plan). The Plan specifically discusses (1) conditions of non-compliance, (2) alternative solutions, (3) recommended solution, (4) remediation plan costs, (5) corrective action, (6) disposal of PCB waste, (7) training, and (8) plan conclusions. The results from inspections by Energy Systems personnel in 2 buildings at K-25 site and statistical extension of this data to 91 selected buildings at the K-25 site indicates that there are approximately 28,000 fluorescent light fixtures containing 47,036 ballasts. Approximately 38,531 contain PCBs and 2,799 of the 38,531 ballasts are leaking PCBs. Review of reportable occurrences at K-25 for the 12 month period of September 1990 through August 1991 shows that Energy Systems personnel reported 69 ballasts leaking PCBs. Each leaking ballast is in non-compliance with 29 CFR 1910 - Table Z-1-A. The age of the K-25 facilities indicate a continued and potential increase in ballasts leaking PCBs. This report considers 4 alternative solutions for dealing with the ballasts leaking PCBs. The advantages and disadvantages of each alternative solution are discussed and ranked using cost of remediation, reduction of health risks, and compliance with OSHA as criteria.

1992-04-30T23:59:59.000Z

393

A scale model study of displacement ventilation with chilled ceilings  

E-Print Network (OSTI)

Displacement ventilation is a form of air-conditioning which provides good air quality and some energy savings. The air quality is better than for a conventional mixed ventilation system. The maximum amount of cooling that ...

Holden, Katherine J. A. (Katherine Joan Adrienne)

1995-01-01T23:59:59.000Z

394

Redesign of ceiling fan - adapted to the Scandinavian market.  

E-Print Network (OSTI)

?? The master degree thesis project, at Halmstad University, was made in cooperation with Hunter Fan, one of the leading fan companies on the American… (more)

Eliasson, Anna

2007-01-01T23:59:59.000Z

395

Undergraduate Handbook 1UNDERGRADUATE HANDBOOK 2013  

E-Print Network (OSTI)

. 1.12. The high-pressure arc lamp studied with x-ray-induced fluorescence consists of a ceramic. The gas under arc- discharge is contained in jackets of ceramic alumina and pyrex, amounting to many. 1.13. X-ray-induced fluorescence spectrum of a 150 W ceramic metal-halide lamp with the lamp off

Waikato, University of

396

U.S. Environmental Protection Agency | December 1, 2010 What to Do if a Compact Fluorescent Light (CFL) Bulb or  

E-Print Network (OSTI)

Fluorescent Light (CFL) Bulb or Fluorescent Tube Light Bulb Breaks in Your Home1 Fluorescent light bulbs contain a small amount of mercury sealed within the glass tubing. When a fluorescent bulb breaks in your home, some of this mercury is released as mercury vapor. The broken bulb can continue to release

McConnell, Terry

397

EA-1664: Finding of No Significant Impact | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4: Finding of No Significant Impact 4: Finding of No Significant Impact EA-1664: Finding of No Significant Impact Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent Lamps The U.S. Department of Energy has determined that the adoption of energy conservation standards for General Service Fluorescent Lamps and Incandescent Reflector Lamps as described in the final rule titled the "energy Conservation Program: Energy Conservation Standards for General Service Fluorescent Lamps and Incandescent Reflector lamps," would not be a major federal action significantly affecting the quality of the human environment. Finding of No Significant Impact for 10 CFR Part 430 Energy Conservation Standards: Energy Conservation Standards for Fluorescent and Incandescent

398

Assaying protein import into mitochondria using fluorescence spectroscopy  

E-Print Network (OSTI)

Most proteins residing in the mitochondrial matrix are synthesized in the cytosol and post-translationally imported into the mitochondrial matrix. The matrix-targeted preproteins traverse the outer mitochondrial membrane (OM) via the Translocase of the Outer Membrane (TOM) complex, and the inner mitochondrial membrane (IM) via the Translocase of the Inner Membrane 23 (TIM23) complex. A novel system was set up to examine the import of matrix-targeted preproteins into mitochondria using fluorescence spectroscopy. The fluorescent probe 6-(7-nitrobenz-2-oxa-1,3-diazol-4- yl)aminohexanoic acid (NBD) was site-specifically incorporated into different positions along the model matrix protein Su9-DHFR. The fluorescent-labeled polypeptides were either fully imported into isolated mitochondria or were arrested along the translocation pathway by the binding of methotrexate (MTX) to the DHFR moiety, creating NBDSu9- DHFRÂ?MTX import intermediates. The NBD-Su9-DHFR polypeptides were able to be fully imported into the mitochondrial matrix in the absence of MTX, and were inaccessible to externally-added iodide ion quenchers. Treatment of the mitochondria with the pore-forming antibiotic alamethicin allowed the iodide ion quenchers access to the matrix through pores in the inner membrane (IM). After Alamethicin treatment the fully-imported NBD-Su9-DHFR polypeptides were accessible to the externally-added iodide ions. The extent of collisional quenching of the NBD fluorophores by the iodide ions was measured as the Stern-Volmer quenching constant, Ksv. Ksv values were obtained for the NBD-Su9-DHFR polypeptides in the presence of MTX (import intermediates) or in the absence of MTX (fully-imported). The Ksv values for NBD-Su9- DHFR import intermediates were similar, despite the location of the NBD probe along the translocation pathway. These Ksv values were similar to those obtained for the fullyimported NBD-Su9-DHFR polypeptides (-MTX). The locations of the varying probe positions along the import pathway were addressed using chemical crosslinking of Su9- DHFR Cys mutants. The use of fluorescence spectroscopy, in association with chemical crosslinking, to analyze the mitochondrial protein import pathways will prove a useful tool to probe the environment of the nascent chain as it is crossing the import pathway (the TOM, TIM23 complexes).

Cargill, Holly Beth

2003-05-01T23:59:59.000Z

399

The Usefulness of Bi-Level Switching; Original Technical Note: November 1998. Revised August, 1999  

SciTech Connect

California's Title 24 Energy Efficiency Building Standard requires multiple lighting level control in all individual offices. Usually, this requirement is fulfilled using bi-level switching. With bi-level switching, each office occupant is provided with two wall switches near the doorway to control their lights. In a typical installation, one switch would control 1/3 of the fluorescent lamps in the ceiling lighting system, while the other switch would control the remaining 2/3 of the lamps. This allows four possible light levels: OFF, 1/3, 2/3 and FULL lighting. Because it has been required by building code since 1983, bi-level switching is common in California office buildings. However, there is no published evidence showing that occupants sometimes use just one switch rather than just switching on both switches when entering the room. Consequently, some have questioned whether bi-level switching is a necessary or desirable requirement for typical office buildings. In fact, the draft national standard, ASHRAE Standard 90.1-1989K apparently does not require bi-level switching at all.

Building Technologies Department

1998-11-01T23:59:59.000Z

400

Fluorescence emission induced by extensive air showers in dependence on atmospheric conditions  

E-Print Network (OSTI)

Charged particles of extensive air showers (EAS), mainly electrons and positrons, initiate the emission of fluorescence light in the Earth's atmosphere. This light provides a calorimetric measurement of the energy of cosmic rays. For reconstructing the primary energy from an observed light track of an EAS, the fluorescence yield in air has to be known in dependence on atmospheric conditions, like air temperature, pressure, and humidity. Several experiments on fluorescence emission have published various sets of data covering different parts of the dependence of the fluorescence yield on atmospheric conditions. Using a compilation of published measurements, a calculation of the fluorescence yield in dependence on altitude is presented. The fluorescence calculation is applied to simulated air showers and different atmospheric profiles to estimate the influence of the atmospheric conditions on the reconstructed shower parameters.

Keilhauer, Bianca

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

DNA fragment sizing and sorting by laser-induced fluorescence  

DOE Patents (OSTI)

A method is provided for obtaining DNA fingerprints using high speed detection systems, such as flow cytometry to determine unique characteristics of DNA pieces from a selected sample. In one characterization the DNA piece is fragmented at preselected sites to produce a plurality of DNA fragments. The DNA piece or the resulting DNA fragments are treated with a dye effective to stain stoichiometrically the DNA fragments. The fluorescence from the dye in the stained fragments is then examined to generate an output functionally related to the number of nucleotides in each one of the DNA fragments. In one embodiment, the intensity of the fluorescence emissions from each fragment is directly proportional to the fragment length. Additional dyes can be bound to the DNA piece and DNA fragments to provide information additional to length information. Oligonucleotide specific dyes and/or hybridization probes can be bound to the DNA fragments to provide information on oligonucleotide distribution or probe hybridization to DNA fragments of different sizes.

Jett, J.H.; Hammond, M.L.; Keller, R.A.; Marrone, B.L.; Martin, J.C.

1992-12-31T23:59:59.000Z

402

Electrokinetic Delivery of Single Fluorescent Biomolecules in Fluidic Nanochannels  

Science Conference Proceedings (OSTI)

We describe the fabrication of sub-100-nanometer-sized channels in a fused silica lab-on-a-chip device and experiments that demonstrate detection of single fluorescently labeled proteins in buffer solution within the device with high signal and low background. The fluorescent biomolecules are transported along the length of the nanochannels by electrophoresis and/or electro-osmosis until they pass into a two-focus laser irradiation zone. Pulse-interleaved excitation and time-resolved single-photon detection with maximum-likelihood analysis enables the location of the biomolecule to be determined. Diffusional transport of the molecules is found to be slowed within the nanochannel, and this facilitates fluidic trapping and/or prolonged measurements on individual biomolecules. Our goal is to actively control the fluidic transport to achieve rapid delivery of each new biomolecule to the sensing zone, following the completion of measurements, or the photobleaching of the prior molecule. We have used computer simulations that include photophysical effects such as triplet crossing and photobleaching of the labels to design control algorithms, which are being implemented in a custom field-programmable-gate-array circuit for the active fluidic control.

Davis, Lloyd M [University of Tennessee Space Institute; Canfield, Brian K [University of Tennessee Space Institute; Li, Xiaoxuan [University of Tennessee Space Institute; Hofmeister, William [University of Tennessee Space Institute; Shen, Guoqing [University of Tennessee Space Institute; Lescano, Isaac [University of Tennessee Space Institute; Bomar, Bruce W [University of Tennessee Space Institute; Wikswo, John P [Vanderbilt University; Markov, Dmitry P [Vanderbilt University; Samson, Philip C [Vanderbilt University; Daniel, Claus [ORNL; Sikorski, Zbigniew [University of Tennessee Space Institute; Robinson, William N [University of Tennessee Space Institute

2008-01-01T23:59:59.000Z

403

Cerenkov emission induced by external beam radiation stimulates molecular fluorescence  

SciTech Connect

Purpose: Cerenkov emission is induced when a charged particle moves faster than the speed of light in a given medium. Both x-ray photons and electrons produce optical Cerenkov photons in everyday radiation therapy of tissue; yet, this phenomenon has never been fully documented. This study quantifies the emissions and also demonstrates that the Cerenkov emission can excite a fluorophore, protoporphyrin IX (PpIX), embedded in biological phantoms. Methods: In this study, Cerenkov emission induced by radiation from a clinical linear accelerator is investigated. Biological mimicking phantoms were irradiated with x-ray photons, with energies of 6 or 18 MV, or electrons at energies 6, 9, 12, 15, or 18 MeV. The Cerenkov emission and the induced molecular fluorescence were detected by a camera or a spectrometer equipped with a fiber optic cable. Results: It is shown that both x-ray photons and electrons, at MeV energies, produce optical Cerenkov photons in tissue mimicking media. Furthermore, we demonstrate that the Cerenkov emission can excite a fluorophore, protoporphyrin IX (PpIX), embedded in biological phantoms. Conclusions: The results here indicate that molecular fluorescence monitoring during external beam radiotherapy is possible.

Axelsson, Johan; Davis, Scott C.; Gladstone, David J.; Pogue, Brian W. [Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire 03755 (United States); Norris Cotton Cancer Center, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire 03766 (United States); Thayer School of Engineering and Department of Physics and Astronomy, Dartmouth College, Hanover, New Hampshire 03755 (United States)

2011-07-15T23:59:59.000Z

404

Building Technologies Program - 1995 Annual Report  

E-Print Network (OSTI)

CFL fixture achieves the highest fixture efficiency byCFL, and a 22-watt Circline™ fluorescent lamp, with fixture efficienciesCFL rather than the typical A-Lamp have the possibility of significantly in- creasing fixture efficiency

Selkowitz, S.E.

2010-01-01T23:59:59.000Z

405

DOE Solar Decathlon: 2009 Building Industry Workshops  

NLE Websites -- All DOE Office Websites (Extended Search)

workshop addresses an array of energy-efficient lighting options, focusing on light-emitting diode (LED) lamps and compact fluorescent lamps. (PDF 3.7 MB) LEED for Homes: Green...

406

New Lighting Technologies  

Science Conference Proceedings (OSTI)

This Electric Power Research Institute (EPRI) technical update continues the technical assessment of advanced lighting technologies in the following product areas—linear LED T8 fluorescent replacements, Edison-based dimmable LED lamps, commercial replacement side-lit LED fixtures, Edison-based reduced-consumption halogen lamps designed to replace 100W incandescent lamps, high bay induction LED lamps, and architectural LED lamps. Many of the products in this year’s report are designed as ...

2012-10-08T23:59:59.000Z

407

Flicker Performance of Modern Lighting Technologies including Impacts of Dimmers  

Science Conference Proceedings (OSTI)

The existing industry standards on flicker measurement and assessment are based on the response of general purpose incandescent lamps. However, worldwide these lamps are being replaced with more energy efficient lamps including Compact Fluorescent Lamps (CFLs) and Light emitting Diode (LED) lamps. In order to keep the flicker standards relevant, the industry standard bodies on the subject are in need of the evidence that compares the flicker performance of new lighting ...

2012-12-12T23:59:59.000Z

408

Optical Imaging of Bacterial Infection in Living Mice Using a Fluorescent Near-Infrared Molecular Probe  

E-Print Network (OSTI)

Academy of Sciences, Beijing 100080, China, NIST Center for Theoretical and Computational Nanosciences substrates,9 and antibiotic drugs.10 Recently, we discovered that fluorescent molecular probes containing syn

Smith, Bradley D.

409

Transmission Nuclear Resonance Fluorescence Measurements of 238U in Thick Targets  

E-Print Network (OSTI)

G. Rusev, and A.P. Tonchev, Transmission-based detection ofas it traverses the transmission detection sheet. The secondTransmission Nuclear Resonance Fluorescence Measurements of

Quiter, Brian J.

2011-01-01T23:59:59.000Z

410

Anatomy-Based Algorithms for Detecting Oral Cancer Using Reflectance and Fluorescence Spectroscopy  

E-Print Network (OSTI)

OBJECTIVES: We used reflectance and fluorescence spectroscopy to noninvasively and quantitatively distinguish benign from dysplastic/malignant oral lesions. We designed diagnostic algorithms to account for differences in ...

McGee, Sasha

411

Fluorescence-based detection methodologies for nitric oxide using transition metal scaffolds  

E-Print Network (OSTI)

Chapter 1. Fluorescence-Based Detection Methodologies for Nitric Oxide: A Review. Chapter 2. Cobalt Chemistry with Mixed Aminotroponimine Salicylaldimine Ligands: Synthesis, Characterization, and Nitric Oxide Reactivity. ...

Hilderbrand, Scott A. (Scott Alan), 1976-

2004-01-01T23:59:59.000Z

412

Examining 239Pu and 240Pu Nuclear Resonance Fluorescence Measurements on Spent Fuel for Nuclear Safeguards  

E-Print Network (OSTI)

S.D. Ambers, “Assesment of Nuclear Resonance Fluorescencefor Spent Nuclear Fuel Assay,” Inst. of Nucl. Mat. Man. ,clandestine material with nuclear resonance fluorescence,”

Quiter, Brian

2013-01-01T23:59:59.000Z

413

Nuclear Resonance Fluorescence to Measure Plutonium Mass in Spent Nuclear Fuel  

E-Print Network (OSTI)

and Nuclear Recoil . . . . . . . . . . . . . . . . . . . . .2 Quantitative Measurements using NRF 2.1 Nuclear ResonanceFuture Work A Transmission Nuclear Resonance Fluorescence

Ludewigt, Bernhard A

2011-01-01T23:59:59.000Z

414

High power light emitting diode based setup for photobleaching fluorescent impurities  

E-Print Network (OSTI)

High power light emitting diode based setup for photobleaching fluorescent impurities Tobias K be photobleached before final sample preparation. The instrument consists of high power light emitting diodes

Kaufman, Laura

415

Shelf life of five meat products displayed under light emitting diode or fluorescent lighting.  

E-Print Network (OSTI)

??Light emitting diode (LED) and fluorescent (FLS) lighting effects on enhanced pork loin chops, beef longissimus dorsi and semimembranosus steaks, ground beef, and ground turkey… (more)

Steele, Kyle Stover

2011-01-01T23:59:59.000Z

416

Fluorescence spectrum analysis using Fourier series modeling for Fluorescein solution in Ethanol  

E-Print Network (OSTI)

We have measured the fluorescence spectrum for fluorescein solution in ethanol with concentration 1 {\\times} 10-3 mol/liter at different temperatures from room temperature to freezing point of solvent, (T = 153, 183, 223, 253, and 303 K) using liquid nitrogen. Table curve 2D version 5.01 program has been used to determine the fitting curve and fitting equation for each fluorescence spectrum. Fourier series (3 {\\times} 2) was the most suitable fitting equation for all spectra. Theoretical fluorescence spectrum of fluorescein in ethanol at T = 183K was calculated and compared with experimental fluorescence spectrum at the same temperature. There is a good similarity between them.

Hadi, Mahasin F

2011-01-01T23:59:59.000Z

417

Excitation-emission spectra and fluorescence quantum yields for fresh and aged biogenic secondary organic aerosols  

SciTech Connect

Certain biogenic secondary organic aerosols (SOA) become absorbent and fluorescent when exposed to reduced nitrogen compounds such as ammonia, amines and their salts. Fluorescent SOA may potentially be mistaken for biological particles by detection methods relying on fluorescence. This work quantifies the spectral distribution and effective quantum yields of fluorescence of SOA generated from two monoterpenes, limonene and a-pinene, and two different oxidants, ozone (O3) and hydroxyl radical (OH). The SOA was generated in a smog chamber, collected on substrates, and aged by exposure to ~100 ppb ammonia vapor in air saturated with water vapor. Absorption and excitation-emission matrix (EEM) spectra of aqueous extracts of aged and control SOA samples were measured, and the effective absorption coefficients and fluorescence quantum yields (~0.005 for 349 nm excitation) were determined from the data. The strongest fluorescence for the limonene-derived SOA was observed for excitation = 420+- 50 nm and emission = 475 +- 38 nm. The window of the strongest fluorescence shifted to excitation = 320 +- 25 nm and emission = 425 +- 38 nm for the a-pinene-derived SOA. Both regions overlap with the excitation-emission matrix (EEM) spectra of some of the fluorophores found in primary biological aerosols. Our study suggests that, despite the low quantum yield, the aged SOA particles should have sufficient fluorescence intensities to interfere with the fluorescence detection of common bioaerosols.

Lee, Hyun Ji; Laskin, Alexander; Laskin, Julia; Nizkorodov, Sergey A.

2013-05-10T23:59:59.000Z

418

Diagnosing breast cancer using diffuse reflectance spectroscopy and intrinsic fluorescence spectroscopy  

E-Print Network (OSTI)

Using diffuse reflectance spectroscopy and intrinsic fluorescence spectroscopy, we have developed an algorithm that successfully classifies normal breast tissue, fibrocystic change, fibroadenoma, and infiltrating ductal ...

Fitzmaurice, Maryann

419

Free Volume Related Fluorescence Properties of Electron Irradiated Chalcone Doped PMMA Films  

Science Conference Proceedings (OSTI)

Effect of electron irradiation on free volume related fluorescence properties of chalcone doped Poly(methyl methacrylate)(PMMA) composite films have been studied using Positron Annihilation and Fluorescence spectroscopic techniques. In this polymer composite, enhancement of fluorescence at lower doses and reduction at higher doses has been observed under electron irradiation. From Positron annihilation studies suggests that at lower doses of irradiation induced crosslinking which affect the free volume properties and inturn hinders the chalcone molecular rotation. At higher doses chain scission process affect matrix relaxation. Under the restricted condition the chromophore molecules likely to emit enhanced fluorescence and its mobility is directly related to the free volume around it.

Ravindrachary, Ismayil V.; Bhajantri, R. F.; Harisha, A. [Department of Physics, Mangalore University, Mangalagangotri - 574 199 (India); Praveena, S. D. [Department of Physics, K.V.G College of Engineering, Kurunjibhag, Sullia, Karnataka - 574 327 (India)

2011-07-15T23:59:59.000Z

420

Capillary electrophoresis-fluorescence line narrowing system (CE-FLNS) for on-line structural characterization  

DOE Patents (OSTI)

Capillary electrophoresis (CE) is interfaced with low temperature fluorescence line-narrowing (FLN) spectroscopy for on-line structural characterization of separated molecular analytes.

Jankowiak, Ryszard J. (Ames, IA); Small, Gerald J. (Ames, IA); Shields, Peter A. (Reading, MA)

1999-04-27T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Advanced Lighting Technologies:Energy Efficiency and Power Quality of Lighting Sources  

Science Conference Proceedings (OSTI)

his EPRI technical update is the third in a series of technical assessments of advanced lighting technologies. A total of seven lighting products were assessed in 2013: low cost screw based light-emitting diode (LED) lamps, retrofit LED ceiling fixtures, suspended LED fixtures, LED-based 2x4 troffers, LED high bay fixtures, innovative LED screw based lamps, and LED hospitality lighting. Prior to beginning an in-depth assessment, the EPRI Lighting Group evaluated each of the tested technologies to ...

2013-12-12T23:59:59.000Z

422

Measurement and model assessment of fluorescence lifetime sensing in multiply scattering media  

E-Print Network (OSTI)

The generation and propagation of fluorescence light within biological tissue offers the potential for biomedical diagnostics and analyte sensing. Arising from an exogenous fluorescent dye injected as a contrast agent or immobilized in a polymer implant, the fluorescent decay kinetics can be sensitive to the tissue??s biochemical environment, providing quantitative in vivo information of the confined tissue site. The impact of light propagation and decay kinetics upon the measured signals is important for consideration, simply because tissue scatters light, giving rise to nanosecond photon time-of-flights that are comparable to fluorescence relaxation kinetics. The goal of this study is to develop a time-dependent model describing (i) the generation of fluorescence from dyes exhibiting multi-exponential or more complex kinetics and (ii) its propagation in scattering media. In the preliminary study, fluorescence lifetime spectroscopy is investigated in tissue-like scattering solution. Two fluorescent dyes, 3,3-diethylthiatricarbocyanine iodide (DTTCI) and Indocynanine Green (ICG), which exhibit distinctly different lifetimes and each exhibits single-exponential decay kinetics, were employed. Measurements of phase-modulation as a function of modulation frequency were made at varying concentration ratios of the two dyes to experimentally simulate fluorescence multi-exponential decay kinetics in non-scattering and scattering solutions. The results suggest that frequency-domain measurements of fluorescent decay kinetics along with models of light propagation may be enhanced by scatter in order to probe kinetics more sensitively than in non-scattering solutions. The next study involved fluorescence lifetime sensing in scattering and non-scattering solutions with a pH sensitive dye, Carboxy Seminaphthofluorescein-1 (C-SNAFL-1), which is known to exhibit multi-exponential decay kinetics. The results demonstrate accurate pH sensing in scattering solution via fluorescence kinetics using a simplified propagation model incorporating an average lifetime. Finally, fluorescence lifetime sensing in immobilized systems were investigated. C-SNAFL-1 was immobilized in poly(ethylene glycol) (PEG) microparticles that were immersed in buffered polystyrene solutions. The results demonstrate the ability to perform pH sensing with fluorescence lifetime without the confounding effect of fluorophore loading or the use of 'reference' measurement within multiply scattering systems. In addition, the stability of the immobilized fluorescence sensor and the reliability of fluorescence lifetime measurement verify the prospect of this technology for implantable purposes.

Kuwana, Eddy

2003-05-01T23:59:59.000Z

423

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 3, Water heaters, pool heaters, direct heating equipment, and mobile home furnaces  

SciTech Connect

This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.

Not Available

1993-11-01T23:59:59.000Z

424

Rapid determination of uranium by x-ray fluorescence  

SciTech Connect

This report describes a method for rapidly determining the amount of uranium using x-ray fluorescence. We add an aliquot of sample solution plus the internal standard element, yttrium, to a 10-ml volumetric flask. We transfer this solution to an x-ray cell and read the L..cap alpha..1 line of uranium and the K..cap alpha..1 line of yttrium. We then compare the ratio of uranium to yttrium for the sample with the ratios obtained from standards. This rapid, highly accurate procedure has a relative standard deviation of 0.69% for samples containing 1 to 5 mg U/ml. 2 refs., 2 figs., 2 tabs.

Martell, C.J.; Hansel, J.M.

1987-05-01T23:59:59.000Z

425

Counting constituents in molecular complexes by fluorescence photon antibunching  

SciTech Connect

Modern single molecule fluorescence microscopy offers new, highly quantitative ways of studying the systems biology of cells while keeping the cells healthy and alive in their natural environment. In this context, a quantum optical technique, photon antibunching, has found a small niche in the continuously growing applications of single molecule techniques to small molecular complexes. Here, we review some of the most recent applications of photon antibunching in biophotonics, and we provide a guide for how to conduct photon antibunching experiments at the single molecule level by applying techniques borrowed from time-correlated single photon counting. We provide a number of new examples for applications of photon antibunching to the study of multichromophoric molecules and small molecular complexes.

Fore, S; Laurence, T; Hollars, C; Huser, T

2007-04-17T23:59:59.000Z

426

Fluorescent Functionalized Mesoporous Silica for Radioactive Material Extraction  

Science Conference Proceedings (OSTI)

Mesoporous silica with covalently bound salicylic acid molecules incorporated in the structure was synthesized with a one-pot, co-condensation reaction at room temperature. The as-synthesized material has a large surface area, uniform particle size, and an ordered pore structure as determined by characterization with transmission electron microscopy, thermal gravimetric analysis, and infrared spectra, etc. Using the strong fluorescence and metal coordination capability of salicylic acid, functionalized mesoporous silica (FMS) was developed to track and extract radionuclide contaminants, such as uranyl [U(VI)] ions encountered in subsurface environments. Adsorption measurements showed a strong affinity of the FMS toward U(VI) with a Kd value of 105 mL/g, which is four orders of magnitude higher than the adsorption of U(VI) onto most of the sediments in natural environments. The new materials have a potential for synergistic environmental monitoring and remediation of the radionuclide U(VI) from contaminated subsurface environments.

Li, Juan; Zhu, Kake; Shang, Jianying; Wang, Donghai; Nie, Zimin; Guo, Ruisong; Liu, Chongxuan; Wang, Zheming; Li, Xiaolin; Liu, Jun

2012-08-01T23:59:59.000Z

427

Fluorescence and Hybrid Detection Aperture of the Pierre Auger Observatory  

E-Print Network (OSTI)

The aperture of the Fluorescence Detector (FD) of the Pierre Auger Observatory is evaluated from simulated events using different detector configurations: mono, stereo, 3-FD and 4-FD. The trigger efficiency has been modeled using shower profiles with ground impacts in the field of view of a single telescope and studying the trigger response (at the different levels) by that telescope and by its neighbours. In addition, analysis cuts imposed by event reconstruction have been applied. The hybrid aperture is then derived for the Auger final extension. Taking into account the actual Surface Detector (SD) array configuration and its trigger response, the aperture is also calculated for a typical configuration of the present phase.

J. A. Bellido; D. D'Urso; H. Geenen; F. Guarino; L. Perrone; S. Petrera; L. Prado Jr.; F. Salamida

2005-07-05T23:59:59.000Z

428

Directed evolution methods for improving polypeptide folding and solubility and superfolder fluorescent proteins generated thereby  

DOE Patents (OSTI)

The current invention provides methods of improving folding of polypeptides using a poorly folding domain as a component of a fusion protein comprising the poorly folding domain and a polypeptide of interest to be improved. The invention also provides novel green fluorescent proteins (GFPs) and red fluorescent proteins that have enhanced folding properties.

Waldo, Geoffrey S. (Santa Fe, NM)

2007-09-18T23:59:59.000Z

429

Studies of the laser-induced fluorescence of explosives and explosive compositions.  

SciTech Connect

Continuing use of explosives by terrorists throughout the world has led to great interest in explosives detection technology, especially in technologies that have potential for standoff detection. This LDRD was undertaken in order to investigate the possible detection of explosive particulates at safe standoff distances in an attempt to identify vehicles that might contain large vehicle bombs (LVBs). The explosives investigated have included the common homogeneous or molecular explosives, 2,4,6-trinitrotoluene (TNT), pentaerythritol tetranitrate (PETN), cyclonite or hexogen (RDX), octogen (HMX), and the heterogeneous explosive, ammonium nitrate/fuel oil (ANFO), and its components. We have investigated standard excited/dispersed fluorescence, laser-excited prompt and delayed dispersed fluorescence using excitation wavelengths of 266 and 355 nm, the effects of polarization of the laser excitation light, and fluorescence imaging microscopy using 365- and 470-nm excitation. The four nitro-based, homogeneous explosives (TNT, PETN, RDX, and HMX) exhibit virtually no native fluorescence, but do exhibit quenching effects of varying magnitude when adsorbed on fluorescing surfaces. Ammonium nitrate and fuel oil mixtures fluoresce primarily due to the fuel oil, and, in some cases, due to the presence of hydrophobic coatings on ammonium nitrate prill or impurities in the ammonium nitrate itself. Pure ammonium nitrate shows no detectable fluorescence. These results are of scientific interest, but they provide little hope for the use of UV-excited fluorescence as a technique to perform safe standoff detection of adsorbed explosive particulates under real-world conditions with a useful degree of reliability.

Hargis, Philip Joseph, Jr. (,; .); Thorne, Lawrence R.; Phifer, Carol Celeste; Parmeter, John Ethan; Schmitt, Randal L.

2006-10-01T23:59:59.000Z

430

Nucleic acid encoding a self-assembling split-fluorescent protein system  

DOE Patents (OSTI)

The invention provides a protein labeling and detection system based on self-complementing fragments of fluorescent and chromophoric proteins. The system of the invention is exemplified with various combinations of self-complementing fragments derived from Aequorea victoria Green Fluorescent Protein (GFP), which are used to detect and quantify protein solubility in multiple assay formats, both in vitro and in vivo.

Waldo, Geoffrey S. (Santa Fe, NM); Cabantous, Stephanie (Los Alamos, NM)

2011-06-07T23:59:59.000Z

431

EA-1881: Energy Conservation Program: Energy Conservation Standards for  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

81: Energy Conservation Program: Energy Conservation Standards 81: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts EA-1881: Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts Summary This EA evaluates the environmental impacts of a proposal to amend energy conservation standards for various consumer products and certain commercial and industrial equipment, including fluorescent lamp ballasts. Public Comment Opportunities No public comment opportunities available at this time. Documents Available for Download October 20, 2011 EA-1881: Finding of No Significant Impact Energy Conservation Program: Energy Conservation Standards for Fluorescent Lamp Ballasts (October 2011) October 5, 2011 EA-1881: Final Environmental Assessment Energy Conservation Program: Energy Conservation Standards for Fluorescent

432

Hand-held X-Ray Fluorescence (XRF) | Open Energy Information  

Open Energy Info (EERE)

Hand-held X-Ray Fluorescence (XRF) Hand-held X-Ray Fluorescence (XRF) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Hand-held X-Ray Fluorescence (XRF) Details Activities (0) Areas (0) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Field Techniques Exploration Sub Group: Data Collection and Mapping Parent Exploration Technique: Data Collection and Mapping Information Provided by Technique Lithology: Bulk and trace element analysis of rocks, minerals, and sediments. Stratigraphic/Structural: Hydrological: Thermal: Dictionary.png Hand-held X-Ray Fluorescence (XRF): Hand-held X-Ray Fluorescence is a portable analytical technique derived from the instrumentation used in traditional lab-based XRF analysis. The technique is used for bulk chemical analysis of rock, mineral, and sediment

433

DOE Withdraws the Energy Star Label from 34 Compact Fluorescent Light Bulbs  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

the Energy Star Label from 34 Compact Fluorescent the Energy Star Label from 34 Compact Fluorescent Light Bulbs DOE Withdraws the Energy Star Label from 34 Compact Fluorescent Light Bulbs January 26, 2010 - 11:41am Addthis Washington, DC - On January 25th, the General Counsel notified 25 manufacturers that the Department of Energy has withdrawn their right to use the Energy Star label on 34 different models of compact fluorescent light bulbs (CFLs). The Department took this action after its off-the-shelf testing revealed that the affected models do not last as long in regular use as Energy Star certification would require. As a result, these manufacturers have been informed that they can no longer ship or sell any of the 34 models of CFLs bearing the Energy Star label on the bulb or its packaging. All compact fluorescent light bulbs use about 75 percent less energy and

434

Cyanine-based probe\\tag-peptide pair for fluorescence protein imaging and fluorescence protein imaging methods  

DOE Patents (OSTI)

A molecular probe comprises two arsenic atoms and at least one cyanine based moiety. A method of producing a molecular probe includes providing a molecule having a first formula, treating the molecule with HgOAc, and subsequently transmetallizing with AsCl.sub.3. The As is liganded to ethanedithiol to produce a probe having a second formula. A method of labeling a peptide includes providing a peptide comprising a tag sequence and contacting the peptide with a biarsenical molecular probe. A complex is formed comprising the tag sequence and the molecular probe. A method of studying a peptide includes providing a mixture containing a peptide comprising a peptide tag sequence, adding a biarsenical probe to the mixture, and monitoring the fluorescence of the mixture.

Mayer-Cumblidge, M. Uljana (Richland, WA); Cao, Haishi (Richland, WA)

2010-08-17T23:59:59.000Z

435

In Situ Measurement of Tropospheric OH Radicals by Laser-Induced Fluorescence—A Description of the KFA Instrument  

Science Conference Proceedings (OSTI)

An instrument for the measurement of tropospheric OH radical concentrations by laser-induced fluorescence spectroscopy has been developed. Ambient air is expanded through a nozzle into a low-pressure fluorescence cell and is irradiated by a ...

F. Holland; M. Hessling; A. Hofzumahaus

1995-10-01T23:59:59.000Z

436

Magnetic fluorescent ballasts: Market data, market imperfections, and policy success  

SciTech Connect

Many economists have strongly questioned engineering-economic studies aimed at demonstrating anomalously slow diffusion of energy-efficient technology and the benefits of regulations to promote such technology. One argument against such studies is that standard techniques of engineering-economics are either inappropriate for or are routinely misapplied in assessing the performance of the market for energy efficiency. This paper presents engineering-economic evidence on the diffusion of energy efficiency improvements that takes account of such critiques. The authors examine the engineering and economic characteristics of standard and energy-efficient magnetic ballasts for fluorescent lighting. Efficient magnetic ballasts represented an excellent investment for 99% of the commercial building floor stock, and a moderately good investment for 0.7% of the commercial floor stock. Still, these ballasts were only being adopted in the 1980s at a rate commensurate with the enactment of appliance efficiency standards in various states. In this case, there is solid empirical evidence for skepticism about the effectiveness of the market mechanism in promoting cost-effective energy efficiency improvements as well as evidence of the benefits of regulation to counteract this shortcoming.

Koomey, J.G.; Sanstad, A.H.; Shown, L.J.

1995-12-01T23:59:59.000Z

437

Nuclear Resonance Fluorescence for Material Verification in Dismantlement  

Science Conference Proceedings (OSTI)

Nuclear resonance fluorescence (NRF) is a well-established physical process that provides an isotope-specific signature that can be exploited for isotopic detection and characterization of samples. Pacific Northwest National Laboratory has been investigating possible applications of NRF for national security. Of the investigated applications, the verification of material in the dismantlement process is the most promising. Through a combination of benchmarking measurements and radiation transport modeling, we have shown that NRF techniques with existing bremsstrahlung photon sources and a modest detection system can be used to detect highly enriched uranium in the quantities and time limits relevant to the dismantlement process. Issues such as orientation, placement and material geometry do not significantly impact the sensitivity of the technique. We have also investigated how shielding of the uranium would be observed through non-NRF processes to enable the accurate assay of the material. This paper will discuss our findings on how NRF and photon-interrogation techniques may be applied to the material verification in the dismantlement process.

Warren, Glen A.; Detwiler, Rebecca S.

2011-10-01T23:59:59.000Z

438

Diagnostic Implications of the Reactivity of Fluorescence Tracers  

SciTech Connect

Measurements of fuel concentration distributions with planar laser induced fluorescence of tracer molecules that are added to a base fuel are commonly used in combustion research and development. It usually is assumed that the tracer concentration follows the parent fuel concentration if physical properties such as those determining evaporation are matched. As an example to address this general issue a computational study of combustion of biacetyl/iso-octane mixtures was performed to investigate how well the concentration of biacetyl represents the concentration of iso-octane. For premixed mixture conditions with flame propagation the spatial concentration profiles of the two species in the flame front are separated by 110 {micro}m at 1 bar and by 11 {micro}m at 10 bar. For practical applications this spatial separation is insignificantly small. However, for conditions that mimic ignition and combustion in diesel and HCCI-like operation the differences in tracer and fuel concentration can be significant, exceeding hundreds of percent. At low initial temperature biacetyl was found to be more stable whereas at higher temperature (>1000K) iso-octane is more stable. Similar findings were obtained for a multi-component fuel comprised of iso-octane, n-heptane, methylcyclohexane, and toluene. It may be assumed that similar differences can exist for other tracer/fuel combinations. Caution has therefore to be applied when interpreting PLIF measurements in homogeneous reaction conditions such as in HCCI engine studies.

Sick, V; Westbrook, C

2008-07-14T23:59:59.000Z

439

Scanning Lidar Based Atmospheric Monitoring for Fluorescent Detectors of Cosmic Showers  

E-Print Network (OSTI)

Measurements of the cosmic-ray air-shower fluorescence at extreme energies require precise knowledge of atmospheric conditions. The absolute calibration of the cosmic-ray energy depends on the absorption of fluorescence light between its origin and point of its detection. To reconstruct basic atmospheric parameters we review a novel analysis method based on two- and multi-angle measurements performed by the scanning backscatter lidar system. Applied inversion methods, optical depth, absorption and backscatter coefficient, as well as other parameters that enter the lidar equation are discussed in connection to the attenuation of the light traveling from shower to fluorescence detector.

A. Filipcic; M. Horvat; D. Veberic; D. Zavrtanik; M. Zavrtanik

2002-02-06T23:59:59.000Z

440

Environmental impacts of lighting technologies - Life cycle assessment and sensitivity analysis  

SciTech Connect

With two regulations, 244/2009 and 245/2009, the European Commission recently put into practice the EuP Directive in the area of lighting devices, aiming to improve energy efficiency in the domestic lighting sector. This article presents a comprehensive life cycle assessment comparison of four different lighting technologies: the tungsten lamp, the halogen lamp, the conventional fluorescent lamp and the compact fluorescent lamp. Taking advantage of the most up-to-date life cycle inventory database available (ecoinvent data version 2.01), all life cycle phases were assessed and the sensitivity of the results for varying assumptions analysed: different qualities of compact fluorescent lamps (production phase), different electricity mixes (use phase), and end-of-life scenarios for WEEE recycling versus municipal solid waste incineration (disposal phase). A functional unit of 'one hour of lighting' was defined and the environmental burdens for the whole life cycle for all four lamp types were calculated, showing a clearly lower impact for the two gas-discharge lamps, i.e. the fluorescent and the compact fluorescent lamp. Differences in the product quality of the compact fluorescent lamps reveal to have only a very small effect on the overall environmental performance of this lamp type; a decline of the actual life time of this lamp type doesn't result in a change of the rank order of the results of the here examined four lamp types. It was also shown that the environmental break-even point of the gas-discharge lamps is reached long before the end of their expected life-span. All in all, it can be concluded that a change from today's tungsten lamp technology to a low-energy-consuming technology such as the compact fluorescent lamp results in a substantial environmental benefit.

Welz, Tobias; Hischier, Roland, E-mail: Roland.Hischier@empa.ch; Hilty, Lorenz M.

2011-04-15T23:59:59.000Z

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Nuclear Resonance Fluorescence at MIT | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

Resonance Fluorescence at MIT Resonance Fluorescence at MIT Nuclear Physics (NP) NP Home About Research Facilities Science Highlights Benefits of NP Spinoff Applications Spinoff Archives SBIR/STTR Applications of Nuclear Science and Technology Funding Opportunities Nuclear Science Advisory Committee (NSAC) News & Resources Contact Information Nuclear Physics U.S. Department of Energy SC-26/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301) 903-3613 F: (301) 903-3833 E: sc.np@science.doe.gov More Information » Spinoff Archives Nuclear Resonance Fluorescence at MIT Print Text Size: A A A RSS Feeds FeedbackShare Page Application/instrumentation: Material Identification and Object Imaging Using Nuclear Resonance Fluorescence Developed at: Massachusetts Institute of Technology

442

Inhibitory study of protein arginine methyltransferase 1 using a fluorescent approach  

SciTech Connect

Protein arginine methyltransferases (PRMTs) play important roles in both normal physiology and human diseases. Deregulation of PRMT activity has been linked to several pathological states such as cancer and cardiovascular disorders. Herein, we report our work of designing and using new fluorescent reporters to perform single-step analysis of substrate binding and methylation by PRMT1. Both fluorescence intensity and anisotropy of the two reporters, R4-FL and H4-FL, were shown to effectively manifest enzyme-substrate interactions, highlighting their application in investigating PRMT inhibitors. In particular, the methylation process of R4-FL can be directly studied using fluorescence intensity readout. By combining the fluorescent measurement with radioactive analysis, we determined that AMI-1 inhibits PRMT1 activity through the mechanism of blocking peptide substrate binding.

Feng You; Xie Nan; Wu Jiang; Yang Chao [Department of Chemistry, Georgia State University, P.O. Box 4098, Atlanta, Georgia 30302 (United States); Zheng, Yujun George [Department of Chemistry, Georgia State University, P.O. Box 4098, Atlanta, Georgia 30302 (United States)], E-mail: yzheng@gsu.edu

2009-02-06T23:59:59.000Z

443

High-throughput screening assay of hepatitis C virus helicase inhibitors using fluorescence-quenching phenomenon  

Science Conference Proceedings (OSTI)

We have developed a novel high-throughput screening assay of hepatitis C virus (HCV) nonstructural protein 3 (NS3) helicase inhibitors using the fluorescence-quenching phenomenon via photoinduced electron transfer between fluorescent dyes and guanine bases. We prepared double-stranded DNA (dsDNA) with a 5'-fluorescent-dye (BODIPY FL)-labeled strand hybridized with a complementary strand, the 3'-end of which has guanine bases. When dsDNA is unwound by helicase, the dye emits fluorescence owing to its release from the guanine bases. Our results demonstrate that this assay is suitable for quantitative assay of HCV NS3 helicase activity and useful for high-throughput screening for inhibitors. Furthermore, we applied this assay to the screening for NS3 helicase inhibitors from cell extracts of microorganisms, and found several cell extracts containing potential inhibitors.

Tani, Hidenori [Department of Life Science and Medical Bio-Science, Waseda University, 2-2 Wakamatsu-cho, Shinjuku-ku, Tokyo 162-8480 (Japan); Institute for Biological Resources and Functions, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566 (Japan); Akimitsu, Nobuyoshi [Radioisotope Center, University of Tokyo, 2-11-16 Yayoi, Bunkyo-ku, Tokyo 113-0032 (Japan); Fujita, Osamu; Matsuda, Yasuyoshi [Institute for Biological Resources and Functions, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566 (Japan); Department of Life Science and Medical Bio-Science, Waseda University, 2-2 Wakamatsu-cho, Shinjuku-ku, Tokyo 162-8480 (Japan); Miyata, Ryo [Institute for Biological Resources and Functions, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566 (Japan); Tsuneda, Satoshi [Department of Life Science and Medical Bio-Science, Waseda University, 2-2 Wakamatsu-cho, Shinjuku-ku, Tokyo 162-8480 (Japan); Igarashi, Masayuki [Microbial Chemistry Research Center, 3-14-23 Kamiosaki, Shinagawa-ku, Tokyo 141-0021 (Japan); Sekiguchi, Yuji [Institute for Biological Resources and Functions, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566 (Japan); Noda, Naohiro [Institute for Biological Resources and Functions, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566 (Japan); Department of Life Science and Medical Bio-Science, Waseda University, 2-2 Wakamatsu-cho, Shinjuku-ku, Tokyo 162-8480 (Japan)], E-mail: noda-naohiro@aist.go.jp

2009-02-20T23:59:59.000Z

444

Mechanism of the efficient quenching of tryptophan fluorescence in human gamma crystallin  

E-Print Network (OSTI)

Quenching of the fluorescence of buried tryptophans (Trps) is an important reporter of protein conformation. Human [gamma]D-crystallin (H[gamma]D-Crys) and human [gamma]S-crystallin (H[gamma]S-Crys) are both very stable ...

Chen, Jiejin, Ph. D. Massachusetts Institute of Technology

2008-01-01T23:59:59.000Z

445

Turn-on fluorescent probes for detecting nitric oxide in biology  

E-Print Network (OSTI)

Chapter 1. Investigating the Biological Roles of Nitric Oxide and Other Reactive Nitrogen Species Using Fluorescent Probes: This chapter presents an overview of recent progress in the field of reactive nitrogen species ...

McQuade, Lindsey Elizabeth, 1981-

2010-01-01T23:59:59.000Z

446

Metal-based turn-on fluorescent probes for nitric oxide sensing  

E-Print Network (OSTI)

Chapter 1. Metal-Based Turn-On Fluorescent Probes for Sensing Nitric Oxide. Nitric oxide, a reactive free radical, regulates a variety of biological processes. The absence of tools to detect NO directly, rapidly, specifically ...

Lim, Mi Hee

2006-01-01T23:59:59.000Z

447

Antibody-Antigen assay design for combined optical tweezers and fluorescence  

E-Print Network (OSTI)

The recent development in combined optical trapping and fluorescence technology promises to enable unbindinig force studies of receptor-ligand interactions, whose specificity play a crucial role in the function of many ...

Ta, Jenny, 1982-

2004-01-01T23:59:59.000Z

448

Computational image analysis of subcellular dynamics in time-lapse fluorescence microscopy  

E-Print Network (OSTI)

The use of image segmentation and motion tracking algorithms was adapted for analyzing time-lapse data of cells with fluorescently labeled protein. Performance metrics were devised and algorithm parameters were matched to ...

Huang, Austin V., 1980-

2005-01-01T23:59:59.000Z

449

An improved understanding of fluorescent Zn(II) sensors and their uses in biological settings  

E-Print Network (OSTI)

Chapter 1. An Introduction to Fluorescent Zn(II) Sensors and Their Applications in Biological Systems This chapter opens with an overview of the numerous roles of zinc in biology, with an emphasis on labile Zn(II), that ...

Wong, Brian Alexander

2009-01-01T23:59:59.000Z

450

Non-invasive detection of oral cancer using reflectance and fluorescence spectroscopy  

E-Print Network (OSTI)

In vivo reflectance and fluorescence spectra were collected from patients with oral lesions, as well as healthy volunteers, in order to evaluate the potential of spectroscopy to serve as a non-invasive tool for the detection ...

McGee, Sasha Alanda

2008-01-01T23:59:59.000Z

451

Nuclear Resonance Fluorescence to Measure Plutonium Mass in Spent Nuclear Fuel  

E-Print Network (OSTI)

and S.J. Thompson,“Determining Plutonium in Spent Fuel withTobin, “Determination of Plutonium Content in Spent FuelFluorescence to Measure Plutonium Mass in Spent Nuclear Fuel

Ludewigt, Bernhard A

2011-01-01T23:59:59.000Z

452

Time resolved fluorescence of CdSe nanocrystals using single molecule spectroscopy  

E-Print Network (OSTI)

A wide variety of spectroscopic studies of CdSe nanocrystals (NCs) are presented in this thesis, all studying some aspect of the temporal evolution of NC fluorescence tinder different conditions. In particular the methods ...

Fisher, Brent R

2005-01-01T23:59:59.000Z

453

Examining 239Pu and 240Pu Nuclear Resonance Fluorescence Measurements on Spent Fuel for Nuclear Safeguards  

E-Print Network (OSTI)

Fluorescence for Spent Nuclear Fuel Assay,” Inst. of Nucl.239 Pu content in spent nuclear fuel [4, 5]. Development ofin the context of spent nuclear fuel, summarizes the results

Quiter, Brian

2013-01-01T23:59:59.000Z

454

LED-Induced Fluorescence System for Tea Classification and Quality Assessment  

E-Print Network (OSTI)

A fluorescence system is developed by using several light emitting diodes (LEDs) with different wavelengths as excitation light sources. The fluorescence detection head consists of multi LED light sources and a multimode fiber for fluorescence collection, where the LEDs and the corresponding filters can be easily chosen to get appropriate excitation wavelengths for different applications. By analyzing fluorescence spectra with the principal component analysis method, the system is utilized in the classification of four types of green tea beverages and two types of black tea beverages. Qualities of the Xihu Longjing tea leaves of different grades, as well as the corresponding liquid tea samples, are studied to further investigate the ability and application of the system in the evaluation of classification/quality of tea and other foods.

Dong, Yongjiang; Mei, Liang; Feng, Chao; Yan, Chunsheng; He, Sailing

2013-01-01T23:59:59.000Z

455

Assessment of Nuclear Resonance Fluorescence for Spent Nuclear Fuel Assay  

SciTech Connect

In nuclear resonance fluorescence (NRF) measurements, resonances are excited by an external photon beam leading to the emission of gamma rays with specific energies that are characteristic of the emitting isotope. NRF promises the unique capability of directly quantifying a specific isotope without the need for unfolding the combined responses of several fissile isotopes as is required in other measurement techniques. We have analyzed the potential of NRF as a non-destructive analysis technique for quantitative measurements of Pu isotopes in spent nuclear fuel (SNF). Given the low concentrations of 239Pu in SNF and its small integrated NRF cross sections, the main challenge in achieving precise and accurate measurements lies in accruing sufficient counting statistics in a reasonable measurement time. Using analytical modeling, and simulations with the radiation transport code MCNPX that has been experimentally tested recently, the backscatter and transmission methods were quantitatively studied for differing photon sources and radiation detector types. Resonant photon count rates and measurement times were estimated for a range of photon source and detection parameters, which were used to determine photon source and gamma-ray detector requirements. The results indicate that systems based on a bremsstrahlung source and present detector technology are not practical for high-precision measurements of 239Pu in SNF. Measurements that achieve the desired uncertainties within hour-long measurements will either require stronger resonances, which may be expressed by other Pu isotopes, or require quasi-monoenergetic photon sources with intensities that are approximately two orders of magnitude higher than those currently being designed or proposed.This work is part of a larger effort sponsored by the Next Generation Safeguards Initiative to develop an integrated instrument, comprised of individual NDA techniques with complementary features, that is fully capable of determining Pu mass in spent fuel assemblies.

Quiter, Brian; Ludewigt, Bernhard; Ambers, Scott

2011-06-30T23:59:59.000Z

456

On-line measurement of lignin in wood pulp by color shift of fluorescence  

DOE Patents (OSTI)

Lignin concentrations from wood pulp samples are measured by applying an excitation light at a selected wavelength to the samples in order to cause the lignin to emit fluorescence. A spectral distribution of the fluorescence emission is then determined. The lignin concentration is then calculated based on the spectral distribution signal. The spectral distribution is quantified by either a wavelength centroid method or a band ratio method. 6 figs.

Jeffers, L.A.; Malito, M.L.

1996-01-23T23:59:59.000Z

457

On-line measurement of lignin in wood pulp by color shift of fluorescence  

DOE Patents (OSTI)

Lignin concentrations from wood pulp samples are measured by applying an excitation light at a selected wavelength to the samples in order to cause the lignin to emit fluorescence. A spectral distribution of the fluorescence emission is then determined. The lignin concentration is then calculated based on the spectral distribution signal. The spectral distribution is quantified by either a wavelength centroid method or a band ratio method.

Jeffers, Larry A. (Washington Township, Stark County, OH); Malito, Michael L. (Liberty Township, Trumbull County, OH)

1996-01-01T23:59:59.000Z

458

Flow method and apparatus for screening chemicals using micro x-ray fluorescence  

DOE Patents (OSTI)

Method and apparatus for screening chemicals using micro x-ray fluorescence. A method for screening a mixture of potential pharmaceutical chemicals for binding to at least one target binder involves flow separating a solution of chemicals and target binders into separated components, exposing them to an x-ray excitation beam, detecting x-ray fluorescence signals from the components, and determining from the signals whether or not a binding event between a chemical and target binder has occurred.

Warner, Benjamin P. (Los Alamos, NM); Havrilla, George J. (Los Alamos, NM); Miller, Thomasin C. (Bartlesville, OK); Lewis, Cris (Los Alamos, NM); Mahan, Cynthia A. (Los Alamos, NM); Wells, Cyndi A. (Los Alamos, NM)

2011-04-26T23:59:59.000Z

459

OTD Technical Activities Report, 2007-2009  

Science Conference Proceedings (OSTI)

... electricity consumption in the US is used for lighting, and white LED lamps are expected to attain at least twice the energy efficiency of fluorescent ...

2010-10-05T23:59:59.000Z

460

Zaidi Abdullah  

NLE Websites -- All DOE Office Websites (Extended Search)

Contacts Media Contacts Portrait Not Available Zaidi Abdullah Science University of Malaysia This Speaker's Seminars The Effects of Table Lamp Shade Shape and Compact Fluorescent...

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Greening Project Status Report: DOE Headquarters  

NLE Websites -- All DOE Office Websites (Extended Search)

* Replaced 114 fluorescent fixtures with ten 250-watt mercury vapor lamps on two garage entrance ramps * Installed direct digital controls for the reheat system to achieve...

462

NOTICE TO APPLICANTS FOR SOLID STATE LIGHTING, IES ...  

Science Conference Proceedings (OSTI)

... _____ 22/P13b* IES LM-66:2000 Single-Ended Compact Fluorescent Lamps - Intensity Measurements ... NVLAP ENERGY EFFICIENT LIGHTING ...

2013-03-28T23:59:59.000Z

463

IMPROVING ENERGY EFFICIENCY AND REDUCING COSTS IN THE DRINKING WATER SUPPLY INDUSTRY: An ENERGY STAR Resource Guide for Energy and Plant Managers  

E-Print Network (OSTI)

Guide described below. ? FEMP Designated Product: Industriallumen.html. ? FEMP Designated Product: Compact Fluorescentfluor_lamp.html. ? FEMP Designated Product: Fluorescent

Brown, Moya Melody, Camilla Dunham Whitehead, Rich

2011-01-01T23:59:59.000Z

464

(12) United States Patent  

Science Conference Proceedings (OSTI)

... located on the opposite side of the stage to remove 40 debris. ... research fluorescence microscope equipped with a lOx objective, a mercury arc lamp ...

2010-07-27T23:59:59.000Z

465

Microsoft Word - 000700S.doc  

NLE Websites -- All DOE Office Websites (Extended Search)

constituents such as mercury lithiumleadnickel cadmium, certain pesticides, as well as mercury-containing thermostats and fluorescent lamps and tubes. 6. Construction rubbish...

466

Understanding Drooping Light Emitting Diodes CEEM | U.S. DOE...  

Office of Science (SC) Website

Impact Understanding "droop" may result in cheaper, more efficient LEDs; LEDs are more energy efficient, smaller, and longer-lived than incandescent lamps or fluorescent...

467

DOE Solar Decathlon: News Blog » Tennessee  

NLE Websites -- All DOE Office Websites (Extended Search)

home's energy efficiency. Compact fluorescent lamps (CFLs) provide the same amount of light as incandescent bulbs but use about 75% less energy. CFLs fit into common household...

468

Accelerated UV-Aging of EVA-based PV Encapsulants and ...  

Science Conference Proceedings (OSTI)

... Bulb filters** Quartz (inner) Borosilicate (outer) ... Test for >26 weeks (4,368 h) continuous light ... Xenon arc, fluorescent UV lamps (UVA, UVB), and ...

2013-11-15T23:59:59.000Z

469

DOE Solar Decathlon: News Blog  

NLE Websites -- All DOE Office Websites (Extended Search)

home's energy efficiency. Compact fluorescent lamps (CFLs) provide the same amount of light as incandescent bulbs but use about 75% less energy. CFLs fit into common household...

470

DOE Solar Decathlon: News Blog » Blog Archive » Technology...  

NLE Websites -- All DOE Office Websites (Extended Search)

home's energy efficiency. Compact fluorescent lamps (CFLs) provide the same amount of light as incandescent bulbs but use about 75% less energy. CFLs fit into common household...

471

Solid-State Lighting Issue 28: Selected Business and Technology...  

NLE Websites -- All DOE Office Websites (Extended Search)

be arranged in modules designed to replace cold cathode fluorescent lamps (CCFL), surface light emitting devices such as electro-luminescent panels, and bulbs for car headlights....

472

Federal Energy Management Program: Federal Energy Efficiency...  

NLE Websites -- All DOE Office Websites (Extended Search)

Guidance and Requirements for Fluorescent Tube Lamps to someone by E-mail Share Federal Energy Management Program: Federal Energy Efficiency Acquisition Guidance and Requirements...

473

BTATEMENT OF CONBZDRUATIOHN REQUEST BY GENERAL ELECTRIC COMPANY...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

was awarded this cooperative agreement in response to a proposal for an affordable compact fluorescent lamp (CFL). The initial phase of this work is being performed under DOE...

474

Neptun Light: Proposed Penalty (2013-CE-3504) | Department of...  

NLE Websites -- All DOE Office Websites (Extended Search)

Civil Penalty that Neptun Light, Inc. failed to certify a variety of medium base compact fluorescent lamps as compliant with the applicable energy conservation standards. DOE...

475

PNNL: Research  

NLE Websites -- All DOE Office Websites (Extended Search)

Light Race to Save Energy, the Environment View full sized image Today's light-emitting diode light bulbs have a slight environmental edge over compact fluorescent lamps....

476

Collaborative Initiatives for Sustainable Products ...  

Science Conference Proceedings (OSTI)

... (EPA) 2. LCA for Sustainable Light Emitting Diode Fluorescent Lamps (DOE) 3. Sustainable Product Initiative (EPA) ? Cradle-to-Gate Tools ...

2009-10-23T23:59:59.000Z

477

U.S. Energy Information Administration (EIA) - Source  

Gasoline and Diesel Fuel Update (EIA)

of incandescent bulbs with more efficient compact fluorescent lighting and light-emitting diode (LED) lamps. Among electric end-use services in the residential sector,...

478

Effect of mechanical vibrations on light emitting diode luminaires.  

E-Print Network (OSTI)

??In this work, a LED and two types of Compact fluorescent lamps were investigated for the intensity variation due to mechanical vibrations in the range… (more)

Paladugu, Jayalakshmi

2009-01-01T23:59:59.000Z

479

Report to Congress on Appliance Energy Efficiency Rulemakings  

NLE Websites -- All DOE Office Websites (Extended Search)

discussed above). The seven products that have two backlogged standards cycles are direct heating equipment, pool heaters, mobile home furnaces, fluorescent lamps, incandescent...

480

Reformulation of a Roofing Tiles Body  

Science Conference Proceedings (OSTI)

The results showed that both sand and illitic clay contribute to reduce the water absorption of ... Characterization of Fluorescent Lamp Glass Waste Powders for ...

Note: This page contains sample records for the topic "fluorescent lamps ceiling" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Appliances and Commercial Equipment Standards  

NLE Websites -- All DOE Office Websites (Extended Search)

General Service Fluorescent and Incandescent Reflector Lamps Energy Conservation Standard Sign up for e-mail updates on regulations for this and other products The Department of...

482

CSA Group  

Science Conference Proceedings (OSTI)

... 1.2: 2001 Self-Ballasted Lamps for General Lighting Services - Performance Requirements. ... [22/S06] ANSI C82.2:2002 Ballast for Fluorescent ...

2013-07-19T23:59:59.000Z

483

GE Nela Park, Product Testing  

Science Conference Proceedings (OSTI)

... 1.2: 2001 Self-Ballasted Lamps for General Lighting Services - Performance Requirements. ... [22/S06] ANSI C82.2:2002 Ballast for Fluorescent ...

2013-07-19T23:59:59.000Z

484

Independent Testing Laboratories, Inc.  

Science Conference Proceedings (OSTI)

... 1.2: 2001 Self-Ballasted Lamps for General Lighting Services - Performance Requirements. ... [22/S06] ANSI C82.2:2002 Ballast for Fluorescent ...

2013-07-19T23:59:59.000Z

485

Quenching-independent measurement of species concentrations in flames by laser-induced fluorescence  

DOE Green Energy (OSTI)

This report describes work accomplished in the last two years on measurement of species concentrations in flames via laser-induced fluorescence. During this period, we have published absolute number densities of atomic hydrogen in subatmospheric, premixed C{sub 2}H{sub 4}/O{sub 2}/Ar flames at equivalence ratios of 1.0 and 1.7 via two-photon excited fluorescence. This work has led to the development of a new single-laser, two-step fluorescence method for the detection of atomic hydrogen in flames. Using photoionization controlled-loss spectroscopy (PICLS), we have verified the T{sup {minus}1/2} dependence of quenching on temperature for atomic hydrogen, in agreement with kinetic theory. Previous work on pyrometry using laser-saturated fluorescence (LSF) and the anomalous fluorescence from pyrene has evolved into publication of a major review paper on temperature measurements by light-scattering methods. Finally, we have demonstrated the feasibility of quantitative LSF measurements of NO concentration by obtaining relative saturation curves and NO fluorescence profiles. 25 refs.

Salmon, J.T.; Carter, C.D.; Laurendeau, N.M.

1990-09-01T23:59:59.000Z

486

Feasibility of x ray fluorescence for spent fuel safeguards  

Science Conference Proceedings (OSTI)

Quantifying the Pu content in spent nuclear fuel is necessary for many reasons, in particular to verify that diversion or other illicit activities have not occurred. Therefore, safeguarding the world's nuclear fuel is paramount to responsible nuclear regulation and public acceptance, but achieving this goal presents many difficulties from both a technical and economic perspective. The Next Generation Safeguards Initiative (NGSI) of NA-24 is funding a large collaborative effort between multiple laboratories and universities to improve spent nuclear fuel safeguards methods and equipment. This effort involves the current work of modeling several different nondestructive assay (NDA) techniques. Several are being researched, because no single NDA technique, in isolation, has the potential to properly characterize fuel assemblies and offer a robust safeguards measure. The insights gained from this research, will be used to down-select from the original set a few of the most promising techniques that complement each other. The goal is to integrate the selected instruments to create an accurate measurement system for fuel verification that is also robust enough to detect diversions. These instruments will be fabricated and tested under realistic conditions. This work examines one of the NDA techniques; the feasibility of using x ray emission peaks from Pu and U to gather information about their relative quantities in the spent fuel. X Ray Fluorescence (XRF), is unique compared to the investigated techniques in that it is the only one able to give the elemental ratio of Pu to U, allowing the possibility of a Pu gram quantity for the assembly to be calculated. XRF also presents many challenges, mainly its low penetration, since the low energy x rays of interest are effectively shielded by the first few millimeters of a fuel pin. This paper will explore the results of Monte Carlo N-Particle eXtended (MCNPX) transport code calculations of spent fuel x ray peaks. The MCNPX simulations will be benchmarked against measurements taken at Oak Ridge. Analysis of the feasibility of XRFs role in spent nuclear fuel safeguards efforts, particularly in the context of the overall NGSI effort will be discussed.

Freeman, Corey Ross [Los Alamos National Laboratory; Mozin, Vladimir [Los Alamos National Laboratory; Tobin, Stephen J [Los Alamos National Laboratory; Fensin, Michael L [Los Alamos National Laboratory; White, Julia M [Los Alamos National Laboratory; Croft, Stephen [Los Alamos National Laboratory; Stafford, Alissa [TAMU; Charlton, William [TAMU

2010-01-01T23:59:59.000Z

487

Daylighting: Measuring the Performance of Light Shelves and Occupant-Controlled Blinds on a Dimmed Lighting Systems  

E-Print Network (OSTI)

The design of a day lighted space is both an art and a science. The biggest challenge facing the lighting designer is to admit only as much light as necessary and distribute it evenly throughout the space without introducing glare or heat. In warm climates such as Florida, it has become common practice in windowed spaces to specify blinds and glazing with high shading coefficients to control glare and minimize heat gain. However, this practice reduces the effectiveness of lighting systems that dim automatically. Improved systems are needed to capture natural daylight and distribute it uniformly throughout a space while controlling heat gain and glare. One such system is the light shelf. Light shelves shade the space from direct sunlight and reflect this sunlight onto the ceiling for a deeper and more uniform distribution. While this is not a new idea, little unbiased empirical data has been collected, outside the laboratory, that compares the performance (energy savings, uniformity, and level) of an automatic daylighting system. This study measures the effectiveness of light shelves and manually controlled horizontal blinds in an automatic daylighting system. Power consumption and interior work-plane lighting levels were compared in four essentially identical private offices. Two offices were configured with an interior light shelf, one with a white diffuse top surface and the other with a specular surface. The third office had no window treatment and the fourth office had horizontal blinds, which were manually adjusted by the user. All offices had two lamp fluorescent luminaires with dimming ballasts (min. 20%) controlled by a ceiling m