National Library of Energy BETA

Sample records for financial office building

  1. Building Technologies Office Overview

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Roland Risser Director, Building Technologies Office Building Technologies Office Energy Efficiency Starts Here. 2 Building Technologies Office Integrated Approach: Improving ...

  2. Office Buildings - Types of Office Buildings

    U.S. Energy Information Administration (EIA) Indexed Site

    administration building Insurance company headquarters building Local insurance agency Social services office Attorney's office Real estate sales office Government office State...

  3. Chief Financial Officer Responsibilities

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2006-11-21

    The Order sets forth requirements for operating the Department of Energy in full compliance with the Chief Financial Officers Act of 1990 and sets standards for sound financial management policies and practices, effective internal controls, accurate and timely financial information, and well-qualified financial managers. Supersedes DOE O 520.1.

  4. Office of Chief Financial Officer

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2001-01-19

    This Order implements the provisions of the Chief Financial Officers Act of 1990 within the Department of Energy. Cancels SEN 34-91. Canceled by DOE O 520.1A.

  5. Building Technologies Office Overview

    SciTech Connect (OSTI)

    2013-04-01

    Building Technologies Office Overview Presentation for the 2013 Building Technologies Office's Program Peer Review

  6. Office of Chief Financial Officer

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    6 DOE/CF-0101 Volume 6 Power Marketing Administrations Southeastern Power Administration Southwestern Power Administration Western Area Power Administration Bonneville Power Administration Department of Energy FY 2015 Congressional Budget Request March 2014 Office of Chief Financial Officer Volume 6 DOE/CF-0101 Volume 6 Power Marketing Administrations Southeastern Power Administration Southwestern Power Administration Western Area Power Administration Bonneville Power Administration Printed with

  7. Office of Chief Financial Officer

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    6 DOE/CF-0112 Volume 6 Power Marketing Administrations Southeastern Power Administration Southwestern Power Administration Western Area Power Administration Bonneville Power Administration Department of Energy FY 2016 Congressional Budget Request February 2015 Office of Chief Financial Officer Volume 6 DOE/CF-0112 Volume 6 Power Marketing Administrations Southeastern Power Administration Southwestern Power Administration Western Area Power Administration Bonneville Power Administration Printed

  8. Office Buildings - Full Report

    U.S. Energy Information Administration (EIA) Indexed Site

    administration building Insurance company headquarters building Local insurance agency Social services office Attorney's office Real estate sales office Government office State...

  9. Office of the Chief Financial Officer .:. Lawrence Berkeley National...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Office of the Chief Financial Officer Office of the Cheif Financial Officer Lawrence Berkeley Naitonal Laboratory Department of Energy Quicklinks: ---...

  10. Office of the Chief Financial Officer

    Broader source: Energy.gov [DOE]

    Welcome to the U.S. Department of Energy, Office of the Chief Financial Officer. The mission of the Office of the Chief Financial Officer is to assure the effective management and financial integrity of Department of Energy programs, activities, and resources by developing and implementing and monitoring Department-wide policies and systems in the areas of budget administration, program analysis and evaluation, finance and accounting, internal controls, corporate financial systems, and strategic planning.

  11. Office Buildings

    U.S. Energy Information Administration (EIA) Indexed Site

    page, please call 202-586-8800. There were enough buildings in the responding sample to report statistics for all of these types except for research and development, which has...

  12. Building Technologies Office Overview

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Roland Risser Director, Building Technologies Office Building Technologies Office Overview Our Homes and Buildings Use 40% of Our Nation's Energy and 75% of Electricity Energy Use Electricity Use Residential Transportation 21 quads 27 quads Commercial 18 quads Industrial 31 quads U.S. Energy Bill for Buildings: $410 billion per year 2 Building Technologies Office (BTO) Ecosystem Emerging Technologies Building Codes Appliance Standards Residential Buildings Integration Commercial Buildings

  13. Office Buildings: Consumption Tables

    U.S. Energy Information Administration (EIA) Indexed Site

    and Type of Office Building Total (trillion Btu) per Building (million Btu) per Square Foot (thousand Btu) Dollars per Million Btu All Office Buildings 1,089 1,475 90.5 16.32...

  14. Office Buildings - Energy Consumption

    U.S. Energy Information Administration (EIA) Indexed Site

    Energy Consumption Office buildings consumed more than 17 percent of the total energy used by the commercial buildings sector (Table 4). At least half of total energy, electricity,...

  15. Office of Chief Financial Officer

    Broader source: Energy.gov (indexed) [DOE]

    Vehicles Manufacturing Loan Program Title 17 Innovative Tech. Loan Guarantee Program Tribal Indian Energy Loan Guarantee Program Office of Indian Energy Policy and Programs Energy ...

  16. Office of Chief Financial Officer

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2001-11-27

    Page Change 1 to DOE O 520.1 modifies the responsibility statement to include NNSA Field CFO positions, modifies Heads of Field Elements responsibilities for consistency with the CFO responsibilities, and makes a minor change to reflect the establishment of the Office of Management, Budget and Evaluation. Cancels SEN 34-9.

  17. Director, Building Technologies Office

    Broader source: Energy.gov [DOE]

    This position is located in the Building Technologies Office (BTO) of the Office of Energy Efficiency and Renewable Energy (EERE). The mission of EERE is to create and sustain American leadership...

  18. February 2016 Office of Chief Financial Officer

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    6 DOE/CF-0124 Volume 6 Power Marketing Administrations Southeastern Power Administration Southwestern Power Administration Western Area Power Administration Bonneville Power Administration Department of Energy FY 2017 Congressional Budget Request February 2016 Office of Chief Financial Officer Volume 6 DOE/CF-0124 Volume 6 Power Marketing Administrations Southeastern Power Administration Southwestern Power Administration Western Area Power Administration Bonneville Power Administration Printed

  19. Office of the Chief Financial Officer Organization Chart | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy About Us » Office of the Chief Financial Officer Organization Chart Office of the Chief Financial Officer Organization Chart OCFOFrontOffice2015.jpg Leadership Organization Contact Us

  20. February 2016 Office of Chief Financial Officer

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    4 DOE/CF-0122 Volume 4 Science Advanced Research Projects Agency-Energy Department of Energy FY 2017 Congressional Budget Request February 2016 Office of Chief Financial Officer Volume 4 DOE/CF-0122 Volume 4 Science Advanced Research Projects Agency-Energy Printed with soy ink on recycled paper Department of Energy FY 2017 Congressional Budget Request Volume 4 Table of Contents Page Appropriation Account Summary

  1. Office of Acquisition and Financial Assessment PIA, Golden Field Office |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Acquisition and Financial Assessment PIA, Golden Field Office Office of Acquisition and Financial Assessment PIA, Golden Field Office Office of Acquisition and Financial Assessment PIA, Golden Field Office Office of Acquisition and Financial Assessment PIA, Golden Field Office (245.98 KB) More Documents & Publications Integrated Safety Management Workshop Registration, PIA, Idaho National Laboratory Occupational Medicine - Assistant PIA, Idaho National Laboratory

  2. Office of the Chief Financial Officer | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Office of the Chief Financial Officer Welcome to the U.S. Department of Energy, Office of the Chief Financial Officer. The mission of the Office of the Chief Financial Officer is to assure the effective management and financial integrity of Department of Energy programs, activities, and resources by developing and implementing and monitoring Department-wide policies and systems in the areas of budget administration, program analysis and evaluation, finance and accounting, internal controls,

  3. Commercial Buildings Energy Consumption Survey - Office Buildings

    Reports and Publications (EIA)

    2010-01-01

    Provides an in-depth look at this building type as reported in the 2003 Commercial Buildings Energy Consumption Survey. Office buildings are the most common type of commercial building and they consumed more than 17% of all energy in the commercial buildings sector in 2003. This special report provides characteristics and energy consumption data by type of office building (e.g. administrative office, government office, medical office) and information on some of the types of equipment found in office buildings: heating and cooling equipment, computers, servers, printers, and photocopiers.

  4. Office of the Chief Financial Officer Annual Report 2009

    SciTech Connect (OSTI)

    Fernandez, Jeffrey

    2009-12-15

    Presented is the 2009 Chief Financial Officer's Annual Report. The data included in this report has been compiled from the Budget Office, the Controller, Procurement and Property Management and the Sponsored Projects Office.

  5. Office of the Chief Financial Officer Strategic Plan2008-2012

    SciTech Connect (OSTI)

    Various

    2007-11-19

    This is an update to the Office of the Chief Financial Officer's (OCFO's) multi-year strategy to continue to build a highly effective, efficient and compliant financial and business approach to support the scientific mission of Lawrence Berkeley National Laboratory (LBNL). The guiding principles of this strategy are to provide the greatest capability for the least cost while continually raising the standards of professional financial management in service to the LBNL science mission.

  6. Annual Report 2008 -- Office of the Chief Financial Officer (OCFO)

    SciTech Connect (OSTI)

    Fernandez, Jeffrey

    2008-12-22

    It is with great pleasure that I present to you the 2008 Chief Financial Officer's Annual Report. The data included in this report has been compiled from the Budget Office, the Controller, Procurement and Property Management and the Sponsored Projects Office. Also included are some financial comparisons with other DOE Laboratories and a glossary of commonly used acronyms.

  7. Joseph Hezir Confirmed as Chief Financial Officer

    Broader source: Energy.gov [DOE]

    Joseph Hezir was confirmed by the Senate on December 4, 2014 as the Department of Energy’s Chief Financial Officer

  8. Advanced Energy Retrofit Guide Office Buildings

    SciTech Connect (OSTI)

    Liu, Guopeng; Liu, Bing; Wang, Weimin; Zhang, Jian; Athalye, Rahul A.; Moser, Dave; Crowe, Eliot; Bengtson, Nick; Effinger, Mark; Webster, Lia; Hatten, Mike

    2011-09-27

    The Advanced Energy Retrofit Guide for Office Buildings is a component of the Department of Energy’s Advanced Energy Retrofit Guides for Existing Buildings series. The aim of the guides is to facilitate a rapid escalation in the number of energy efficiency projects in existing buildings and to enhance the quality and depth of those projects. By presenting general project planning guidance as well as financial payback metrics for the most common energy efficiency measures, these guides provide a practical roadmap to effectively planning and implementing performance improvements for existing buildings.

  9. Building Technologies Office Overview

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Campaign quantifies actual energy savings, market uptake trajectory, and adoption by ... realize energy savings through optimal control of building subsystems. * Reduce cost to ...

  10. Building Technologies Office Overview

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Building Energy Asset Tool Market Stimulation Digital Tools & Solutions Lock-In Savings ... & Standards Tools & Programs Market Transformation No Codes IECC 200912 90% Compliance ...

  11. A Look at Office Buildings - Index

    U.S. Energy Information Administration (EIA) Indexed Site

    law office, or medical office. An office building may also be part of a campus or complex, such as an administrative building on a college campus. (See Description of Building...

  12. Office of Chief Financial Officer DOE/CF-0125

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    DOE/CF-0125 Budget in Brief Department of Energy FY 2017 Congressional Budget Request February 2016 Office of Chief Financial Officer DOE/CF-0125 Budget in Brief Printed with soy ink on recycled paper Department of Energy FY 2017 Congressional Budget Request FY 2017 BUDGET IN BRIEF TABLE OF CONTENTS Overview

  13. Energy use in office buildings

    SciTech Connect (OSTI)

    1980-10-01

    This is the report on Task IB, Familiarization with Additional Data Collection Plans of Annual Survey of BOMA Member and Non-Member Buildings in 20 Cities, of the Energy Use in Office Buildings project. The purpose of the work was to monitor and understand the efforts of the Building Owners and Managers Association International (BOMA) in gathering an energy-use-oriented data base. In order to obtain an improved data base encompassing a broad spectrum of office space and with information suitable for energy analysis in greater detail than is currently available, BOMA undertook a major data-collection effort. Based on a consideration of geographic area, climate, population, and availability of data, BOMA selected twenty cities for data collection. BOMA listed all of the major office space - buildings in excess of 40,000 square feet - in each of the cities. Tax-assessment records, local maps, Chamber of Commerce data, recent industrial-development programs, results of related studies, and local-realtor input were used in an effort to assemble a comprehensive office-building inventory. In order to verify the accuracy and completeness of the building lists, BOMA assembled an Ad-Hoc Review Committee in each city to review the assembled inventory of space. A questionnaire on office-building energy use and building characteristics was developed. In each city BOMA assembled a data collection team operating under the supervision of its regional affiliate to gather the data. For each city a random sample of buildings was selected, and data were gathered. Responses for over 1000 buildings were obtained.

  14. Office of the Chief Financial Officer Annual Report 2010

    SciTech Connect (OSTI)

    Fernandez, Jeffrey

    2010-12-20

    In March, a review team consisting of CFOs from other national laboratories, industry, and members of the University of California Office of the President (UCOP) convened for three days to conduct a comprehensive peer review of the OCFO. This was the first time in almost a decade that the financial operations of the Laboratory had been reviewed. The Committee relayed their observations on our strengths, and their very thoughtful recommendations for improvement, which we are actively pursuing. These improvements, when implemented, will benefit the entire Laboratory for many years to come. The complete report is available on the OCFO website (www.lbl.gov/Workplace/CFO). In August, the senior management team of the OCFO participated in a strategic planning retreat. The purpose of the two and a half day exercise was, of course, to update our strategic plan, but instead of spending days developing a written document, we enlisted the expertise of a seasoned journalist who also happens to be a very talented graphic artist. He listened carefully to our ideas and committed them to a visual roadmap. All members of the OCFO, Business Managers, and the Laboratory Leadership Team reviewed this draft roadmap. By having a completely visual strategic plan that is posted widely throughout the OCFO, all employees can easily see and identify with the goals that we are all working towards. FY2010 was an extraordinary year. The Laboratory welcomed its seventh Director, Dr. Paul Alivisatos, who wasted no time communicating his vision and priorities for Berkeley Lab. They include five very ambitious initiatives: Carbon Cycle 2.0, The Next Generation Light Source, a Safe and Efficient Lab, Building Community, and Space. In response, the Office of the Chief Financial Officer (OCFO) developed twelve specific initiatives that align completely with these five priorities. We will be very focused on these in the coming fiscal year, but for now, let's review what happened in FY2010. FY2010 was a

  15. February 2016 Office of Chief Financial Officer Laboratory Tables

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Laboratory Tables Preliminary Department of Energy FY 2017 Congressional Budget Request DOE/CF-0126 February 2016 Office of Chief Financial Officer Laboratory Tables Preliminary Printed with soy ink on recycled paper The numbers depicted in this document represent the gross level of DOE budget authority for the years displayed. The figures include both the discretionary and mandatory funding in the budget. They do not consider revenues/receipts, use of prior year balances, deferrals,

  16. February 2016 Office of Chief Financial Officer State Tables

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    State Tables Preliminary Department of Energy FY 2017 Congressional Budget Request DOE/CF-0127 February 2016 Office of Chief Financial Officer State Tables Preliminary Printed with soy ink on recycled paper The numbers depicted in this document represent the gross level of DOE budget authority for the years displayed. The figures include both the discretionary and mandatory funding in the budget. They do not consider revenues/receipts, use of prior year balances, deferrals, rescissions, or other

  17. moveLINQ PIA, Office of the Chief Financial Officer | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    moveLINQ PIA, Office of the Chief Financial Officer moveLINQ PIA, Office of the Chief Financial Officer moveLINQ PIA, Office of the Chief Financial Officer moveLINQ PIA, Office of the Chief Financial Officer (1.38 MB) More Documents & Publications Integrated Safety Management Workshop Registration, PIA, Idaho National Laboratory PIA - Bonneville Power Adminstration Ethics Helpline Occupational Medicine - Assistant

  18. Fuel Cell Technologies Office Past Financial Opportunities and...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Fuel Cell Technologies Office Past Financial Opportunities and Selections Past funding opportunities from the U.S. Department of Energy's (DOE's) Fuel Cell Technologies Office are ...

  19. Office Buildings - End-Use Equipment

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    Information Administration, 2003 Commercial Buildings Energy Consumption Survey. More computers, dedicated servers, printers, and photocopiers were used in office buildings than in...

  20. 2013 Building Technologies Office Program Peer Review Report...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    3 Building Technologies Office Program Peer Review Report 2013 Building Technologies Office Program Peer Review Report The 2013 Building Technologies Office Program Peer Review ...

  1. Building Technologies Office Peer Review | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    About Building Technologies Office Peer Review Building Technologies Office Peer Review The Building Technologies Office (BTO) hosts an annual peer review. The event is open to ...

  2. 2014 Building Technologies Office Program Peer Review Report...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building Technologies Office Program Peer Review Report 2014 Building Technologies Office Program Peer Review Report The 2014 Building Technologies Office Program Peer Review ...

  3. 2015 Building Technologies Office Program Peer Review Report...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building Technologies Office Program Peer Review Report 2015 Building Technologies Office Program Peer Review Report The 2015 Building Technologies Office Program Peer Review ...

  4. Building Technologies Office Projects Map | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building Technologies Office Projects Map Building Technologies Office Projects Map Welcome to the Building Technologies Office Projects Map. Here you will find listings for our ...

  5. An Overview of the Building Technologies Office

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Driving Innovation, Speeding Adoption, Scaling Savings An Overview of the Building Technologies Office Roland Risser Director, Building Technologies Office National Energy Consumption Costs U.S. $410 billion to power 2 National Electricity Use Our homes and buildings use 76% of all U.S. electricity 3 The Opportunity: Energy Savings Potential for Buildings and Homes Reduce building energy use by 50% 4 BTO Budget: FY2013 - Proposed FY2016 $0 $50 $100 $150 $200 $250 $300 Residential Buildings

  6. Office of the Assistant General Counsel for Procurement and Financial

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Assistance | Department of Energy Services » Transactions, Technology and Contractor Human Resources » Office of the Assistant General Counsel for Procurement and Financial Assistance Office of the Assistant General Counsel for Procurement and Financial Assistance The Office of the Assistant General Counsel for Procurement and Financial Assistance provides legal support and advice regarding the Department's massive contractual expenditures and financial assistance policy and activities.

  7. Current Fuel Cell Technologies Office Financial Opportunities | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Energy Financial Opportunities » Current Fuel Cell Technologies Office Financial Opportunities Current Fuel Cell Technologies Office Financial Opportunities Current hydrogen-related funding opportunities through the U.S. Department of Energy's (DOE) Fuel Cell Technologies Office (FCTO) are listed below. FCTO offers opportunities for both financial and technical assistance. Although FCTO attempts to maintain current information on these solicitations, the official source for funding

  8. building tech office | netl.doe.gov

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Building Technologies Office The U.S. Department of Energy (DOE) advances building energy performance through the development and promotion of efficient, affordable, and high-impact technologies, systems and practices. The long-term goal of the Building Technologies Office is to reduce energy use by 50%, compared to a 2010 baseline. To secure these savings, research, development, demonstration, and deployment of next-generation building technologies are needed to advance building systems and

  9. Office of the Chief Financial Officer Annual Report 2007

    SciTech Connect (OSTI)

    Fernandez, Jeffrey

    2007-12-18

    2007 was a year of progress and challenges for the Office of the Chief Financial Officer (OCFO). I believe that with the addition of a new Controller, the OCFO senior management team is stronger than ever. With the new Controller on board, the senior management team spent two intensive days updating our strategic plan for the next five years ending in 2012, while making sure that we continue to execute on our existing strategic initiatives. In 2007 the Budget Office, teaming with Human Resources, worked diligently with our colleagues on campus to reengineer the Multi-Location Appointment (MLA) process, making it easier for our Principal Investigators (PIs) to work simultaneously between the Laboratory and UC campuses. The hiring of a point-of-contact in Human Resources to administer the program will also make the process flow smoother. In order to increase our financial flexibility, the OCFO worked with the Department of Energy (DOE) to win approval to reduce the burden rates on research and development (R&D) subcontracts and Intra-University Transfers (IUT). The Budget Office also performed a 'return on investment' (ROI) analysis to secure UCRP funding for a much needed vocational rehabilitation counselor. This new counselor now works with employees who are on medical leave to ensure that they can return to work in a more timely fashion, or if not able to return, usher them through the various options available to them. Under the direction of the new Controller, PriceWaterhouse Coopers (PWC) performed their annual audit of the Laboratory's financial data and reported positive results. In partnership with the Financial Policy and Training Office, the Controller's Office also helped to launch self-assessments of some of our financial processes, including timekeeping and resource adjustments. These self assessments were conducted to promote efficiencies and mitigate risk. In some cases they provided assurance that our practices are sound, and in others highlighted

  10. Fuel Cell Technologies Office Financial Opportunities | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Financial Opportunities Fuel Cell Technologies Office Financial Opportunities The U.S. Department of Energy (DOE) Fuel Cell Technologies Office (FCTO) offers information about current and past financial opportunities, requests for information, and links to related opportunities from other DOE offices and federal organizations. The FCTO mission is to research, develop, and validate hydrogen production, delivery, storage, and fuel cell technologies. In carrying out this mission, FCTO

  11. Building Technologies Office Window and Envelope Technologies...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building Technologies Office Window and Envelope Technologies Emerging Technologies R&D Program Karma Sawyer, Ph.D. karma.sawyer@ee.doe.gov BTO Goal Reduce building energy use by ...

  12. Office of the Assistant General Counsel for Procurement and Financial...

    Broader source: Energy.gov (indexed) [DOE]

    contractual expenditures and financial assistance policy and activities. The office reviews and provides advice and assistance in the development of DOE procurement,...

  13. Building Technologies Office At-A-Glance

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    BUILDING TECHNOLOGIES OFFICE FY 2017 BUDGET AT-A-GLANCE Buildings and homes use more than 73% of the electrical energy consumed in the United States. They also consume 40% of the nation's total energy, with an annual energy bill of $430 billion. These energy bills can be cost effectively reduced by 20%-50% or more through various energy-efficient technologies and techniques. The Building Technologies Office (BTO) will continue to develop and demonstrate advanced building efficiency technologies

  14. Buildings Technology Office Residential Buildings Integration...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... Summaries Building America, ARIES: High Performance Factory Built Housing Presenter: Jordan Dentz, ARIESThe Levy Partnership Project Goal Provide factory homebuilders with high ...

  15. Vehicle Technologies Office: Financial Opportunities | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Financial Opportunities Vehicle Technologies Office: Financial Opportunities The Vehicle Technologies Office (VTO) supports high impact projects that can significantly advance its mission to develop more energy efficient and environmentally friendly highway transportation technologies that enable America to use less petroleum. VTO is strongly committed to partnerships to help ensure the eventual market acceptance of the technologies being developed. New funding opportunities are announced

  16. ISU offering Financial Building Blocks sessions | The Ames Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ISU offering Financial Building Blocks sessions Money is often considered the number one stressor. Your relationships, focus, safety and physical health may be impacted. Reduce the stress in your life by getting your finances under control. Build your financial knowledge and your skills. Iowa State University is offering five sessions geared towards informing employees how to build a sound financial future. The sessions will be presented by Brian Hood, a CFP from the Legacy Financial Group. As a

  17. Building Technologies Office 2014 Highlights | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    2014 Highlights Building Technologies Office 2014 Highlights View a summary of select 2014 accomplishments from DOE's Building Technologies Office. Building Technologies Office 2014 Highlights (2.6 MB) More Documents & Publications Multi-Year Program Plan Building Technologies Office Overview - 2013 Peer Review Building Technologies Office Overview - 2015

  18. Reference Buildings by Building Type: Medium office

    Broader source: Energy.gov [DOE]

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  19. Reference Buildings by Building Type: Small office

    Broader source: Energy.gov [DOE]

    In addition to the ZIP file for each building type, you can directly view the "scorecard" spreadsheet that summarizes the inputs and results for each location. This Microsoft Excel spreadsheet is also included in the ZIP file. For version 1.4, only the IDF file is included.

  20. Building Technologies Office | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building Technologies Office The Future of Air Conditioning for Buildings Report The Future of Air Conditioning for Buildings Report This report characterizes the current landscape and trends in the global air conditioning (A/C) market, including discussion of both direct and indirect climate impacts, and potential global warming impacts from growing global A/C usage. Read more Energy Department Invests $19 Million to Improve Efficiency of Nation's Buildings Energy Department Invests $19 Million

  1. Building Technologies Office Program Peer Review

    Broader source: Energy.gov [DOE]

    The Building Technologies Office (BTO) hosts an annual programmatic peer review. The event is open to the public and will provide the opportunity for stakeholders to learn more about BTO research, development, demonstration and deployment projects.

  2. Building Technologies Office: 179D DOE Calculator

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    179D DOE Calculator EERE Building Technologies Office 179D DOE Calculator Printable Version Bookmark and Share What is the 179D federal tax deduction? Section 179D of the...

  3. Single Audit Act Initiatives by the Office of Risk Management, Office of the Chief Financial Officer Activities

    Broader source: Energy.gov [DOE]

    This Flash forwards a memorandum from the Chief Financial Officer on new initiatives relating to the Single Audit Act and Office of Management and Budget Circular A-1 33. The Office of Risk Management will provide services to assist DOE'S acquisition and financial assistance personnel in the review and use of audits performed under the Act and Circular.

  4. Building Technologies Office Overview - 2013 Peer Review | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building Technologies Office Overview Presentation for the 2013 Building Technologies Office's Program Peer Review btooverviewrisser040213.pdf (2.55 MB) More Documents & ...

  5. Building Technologies Office 2015 Highlights | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    2015 Highlights Building Technologies Office 2015 Highlights View a summary of select 2015 accomplishments from DOE's Building Technologies Office. Building Technologies Office 2015 Highlights (3.51 MB) More Documents & Publications The Future of Air Conditioning for Buildings Report Research & Development Roadmap: Next-Generation Low Global Warming Potential Refrigerants Building Technologies Office Overview - 2016 BTO Peer Review

  6. Fuel Cell Technologies Office Past Financial Opportunities and Selections |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Past Financial Opportunities and Selections Fuel Cell Technologies Office Past Financial Opportunities and Selections Past funding opportunities from the U.S. Department of Energy's (DOE's) Fuel Cell Technologies Office are listed below. Since 2003, DOE has awarded funding to a number of science and research projects to support research, development, and demonstration of hydrogen and fuel cell technologies. Find information about current funding opportunities. The

  7. Special Inquiry on the Office of the Chief Financial Officer...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Information Technology Expenditures OAS-RA-L-12-01 November 2011 Department of Energy ... Chief Information Officer IG Report No. OAS-RA-L-12-01 CUSTOMER RESPONSE FORM The Office ...

  8. Achieving 50% Energy Savings in Office Buildings, Advanced Energy Design Guides: Office Buildings (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2014-09-01

    This fact sheet summarizes recommendations for designing new office buildings that result in 50% less energy use than conventional designs meeting minimum code requirements. The recommendations are drawn from the Advanced Energy Design Guide for Small to Medium Office Buildings, an ASHRAE publication that provides comprehensive recommendations for designing low-energy-use office buildings with gross floor areas up to 100,000 ft2 (see sidebar). Designed as a stand-alone document, this fact sheet provides key principles and a set of prescriptive design recommendations appropriate for smaller office buildings with insufficient budgets to fully implement best practices for integrated design and optimized performance. The recommendations have undergone a thorough analysis and review process through ASHRAE, and have been deemed the best combination of measures to achieve 50% savings in the greatest number of office buildings.

  9. Office of Chief Financial Officer DOE/CF-0113

    Energy Savers [EERE]

    ... FERC also reviews proposals to build liquefied natural gas (LNG) terminals as well as ... and storage projects, authorizing LNG facilities, and, in certain circumstances, ...

  10. 2015 Building Technologies Office Program Peer Review Report | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Energy Building Technologies Office Program Peer Review Report 2015 Building Technologies Office Program Peer Review Report The 2015 Building Technologies Office Program Peer Review Report summarizes the results of the 2015 Building Technologies Office (BTO) Peer Review, which was held in Vienna, Virginia, on April 14-16, 2015. Read the report 2015 BTO Peer Review Report (10.27 MB) More Documents & Publications 2014 Building Technologies Office Program Peer Review Report Market

  11. 2014 Building Technologies Office Program Peer Review Report | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Energy Building Technologies Office Program Peer Review Report 2014 Building Technologies Office Program Peer Review Report The 2014 Building Technologies Office Program Peer Review Report summarizes the results of the 2014 Building Technologies Office (BTO) Peer Review, which was held in Arlington, Virginia, on April 22-24, 2014. Read the report 2014 BTO Peer Review Report (12.66 MB) More Documents & Publications 2015 Building Technologies Office Program Peer Review Report Emerging

  12. Building Technologies Office 2016 Peer Review

    Broader source: Energy.gov [DOE]

    The 2016 Department of Energy (DOE) Building Technologies Office Peer Review will be held April 4-7, 2016 at the Falls Church Marriott Fairview Park, 3111 Fairview Park Drive, Falls Church, VA 22042. Space for the event is limited and registration is required.

  13. Building Technologies Office Peer Review 2015

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy (DOE) Building Technologies Office is hosting its third annual Program Peer Review on April 14-16, 2015 in Vienna, Virginia. The event is open to the public and will provide the opportunity for stakeholders to learn more about BTO research, development, demonstration and deployment projects. Space for the event is limited and registration is required.

  14. Contact the Building Technologies Office | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    About » Contact the Building Technologies Office Contact the Building Technologies Office The Building Technologies Office always welcomes your feedback and suggestions. Contact us via mail, phone or email. Address U.S. Department of Energy Building Technologies Office (BTO) Mail Stop EE-2J 1000 Independence Ave, SW Washington, DC 20585 Email Buildings@ee.doe.gov Phone Number 202.586.9127 Media Inquiries For media inquiries, please email the EERE communications team at EE.Media@ee.doe.gov. Web

  15. Office of the Assistant General Counsel for Procurement and Financial Assistance

    Broader source: Energy.gov [DOE]

    The Office of the Assistant General Counsel for Procurement and Financial Assistance provides legal support and advice regarding the Department's massive contractual expenditures and financial...

  16. Delaware Company Breathes New Life into Old Post Office Building...

    Office of Environmental Management (EM)

    Company Breathes New Life into Old Post Office Building Delaware Company Breathes New Life into Old Post Office Building November 26, 2013 - 12:51pm Addthis Thanks to the Energy ...

  17. 2013 DOE Building Technologies Office Program Review | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    DOE Building Technologies Office Program Review 2013 DOE Building Technologies Office Program Review The 2013 Department of Energy (DOE) Building Technologies Office Program Review was held April 2-4, 2013 in Washington, DC. This inaugural review encompassed active work done by the Building Technologies Office (BTO), with a total of 59 individual activities reviewed. Sixty independent experts assessed the progress and contributions of each project toward BTO's mission and goals, and these

  18. 2013 Building Technologies Office Program Peer Review Report | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Energy 3 Building Technologies Office Program Peer Review Report 2013 Building Technologies Office Program Peer Review Report The 2013 Building Technologies Office Program Peer Review Report summarizes the results of the 2013 Building Technologies Office (BTO) peer review, which was held in Washington, D.C., on April 2-4, 2013. The review was attended by over 300 participants and included presentations on 59 BTO-funded projects: 29 from BTO's Emerging Technologies Program, 20 from the

  19. Buildings Energy Data Book: 3.6 Office Building Markets and Companies

    Buildings Energy Data Book [EERE]

    3 Energy Consumption and Expenditures per Square Foot of Office Floorspace, by Function and Class (1) | | Medical Offices | Financial Offices | Corporate Facilities(2) | Class A | Class B | Class C | | All Buildings | Note(s): Source(s): 2006 2004 Energy Intensity Energy Energy Intensity Energy (thousand Btu/SF) Expenditures ($2010/SF) (thousand Btu/SF) Expenditures ($2010/SF) 90.79 2.56 N.A. 2.36 N.A. 3.12 N.A. 3.32 96.78 2.74 89.38 2.72 81.88 2.44 78.84 2.08 74.87 2.30 N.A. 2.04 1) Categories

  20. Building Technologies Office 2015 Highlights | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building Technologies Office 2015 Highlights Building Technologies Office 2015 Highlights Building Technologies Office 2015 Highlights Table of Contents Feature Story: Major Advances toward Low-GWP Cooling Advancing Technology to Market Making a Difference in the Marketplace Design Solutions for Building Industry Locking in Energy Savings The Future of Buildings Employee Profile: Dr. Jason Hartke Download PDF Version >> bto_highlights_2015_director_letter_011416.png Roland Risser Dear

  1. Office Buildings: Assessing and Reducing Plug and Process Loads in Office Buildings (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-04-01

    Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly large fraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in office spaces are poorly understood.

  2. About the Building Technologies Office | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    About the Building Technologies Office About the Building Technologies Office What We Do We lead a vast network of research and industry partners to continually develop innovative, cost-effective energy saving solutions-better products, better new homes, better ways to improve older homes, and better buildings in which we work, shop, and lead our everyday lives. The Building Technologies Office's Multi-Year Program Plan for Fiscal Years 2016-2020 provides a roadmap of our strategies and goals

  3. Highlighting High Performance Buildings: Department of Environmental Protection-Cambria Office Building, Ebensburg, Pennsylvania

    SciTech Connect (OSTI)

    2001-11-01

    The 36,000-square-foot Cambria Office building used integrated design to minimize energy use, pollution and environmental impact the building will create over its lifetime.

  4. Property:Building/FloorAreaOffices | Open Energy Information

    Open Energy Info (EERE)

    Property Edit with form History Property:BuildingFloorAreaOffices Jump to: navigation, search This is a property of type Number. Floor area for Offices Pages using the property...

  5. Building Technologies Office Overview - 2014 Peer Review | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy 4 Peer Review Building Technologies Office Overview - 2014 Peer Review Presenter: Roland Risser, U.S. Department of Energy Cutting our nation's energy consumption calls for cutting-edge, energy-efficient solutions. That's where the Building Technologies Office comes in. We are researching, developing, and deploying cost-effective solutions to cut building energy use in half by 2030. Our office will examine the feedback from the 2014 Program Peer Review to see what's working for us,

  6. How to Select Lighting Controls for Offices and Public Buildings |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Select Lighting Controls for Offices and Public Buildings How to Select Lighting Controls for Offices and Public Buildings Fact sheet details agency guidelines for selecting lighting controls for offices and public buildings to save operating costs and energy. Download the fact sheet. (91.23 KB) More Documents & Publications Wireless Occupancy Sensors for Lighting Controls: An Applications Guide for Federal Facility Managers Exterior LED Lighting Projects at

  7. Building Technologies Office 2014 Program Peer Review | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy 4 Program Peer Review Building Technologies Office 2014 Program Peer Review The 2014 Department of Energy (DOE) Building Technologies Office Peer Review was held April 22-24, 2014 in Arlington, Virginia. This second annual review encompassed active work done by the Building Technologies Office (BTO). Independent experts assessed the progress and contributions of each project toward BTO's mission and goals, and these assessments will be used to enhance the management of existing

  8. Building Technologies Office Challenges National Labs to Rethink...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... DOE Announces JUMP Initiative Winners, Launches New Crowdsourcing Calls at Bay Area Maker Faire Building Technologies Office Challenges National Labs to Rethink Market ...

  9. Building Technologies Office Overview - 2015 Peer Review | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Building Technologies Office Overview - 2015 Peer Review Presenter: Roland Risser, U.S. ... View the Presentation BTO Overview 2015 - Roland Risser (1.6 MB) More Documents & ...

  10. Behavioral Opportunities for Energy Savings in Office Buildings...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Behavioral Opportunities for Energy Savings in Office Buildings: a London Field Experiment Report details a controlled field experiment to reduce energy use and greenhouse gas ...

  11. Archive Reference Buildings by Building Type: Small office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the reference buildings for new construction commercial buildings, organized by building type and location. A summary of building types and climate zones is...

  12. Building Technologies Office FY 2016 Budget At-A-Glance

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    BUILDING TECHNOLOGIES OFFICE FY 2016 BUDGET AT-A-GLANCE Buildings and homes use more than 73% of the electrical energy consumed in the United States. They also consume 40% of the nation's total energy, with an annual energy bill of $430 billion. These energy bills can be cost effectively reduced by 20%-50% or more through various energy-efficient technologies and techniques. The Building Technologies Office (BTO) will continue to develop and demonstrate advanced building efficiency technologies

  13. DOE Building Technologies Office seeks science and engineering graduate

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    students for pilot program in building to grid integration DOE Building Technologies Office seeks science and engineering graduate students for 2016-2017 pilot program to research building to grid integration Deadline for applying is Nov. 15, 2015, at 11:59 p.m. EST FOR IMMEDIATE RELEASE Nov. 9, 2015 FY16-05 OAK RIDGE, Tenn.-The Department of Energy's Building Technologies Office is seeking graduate students interested in exploring energy systems of buildings and how building assets or

  14. Building Technologies Office | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    will develop innovative techniques for improving home construction and retrofit processes. ... While commercial building owners generally have control over building systems and ...

  15. Archived Reference Building Type: Medium office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed in or after 1980, organized by building type and location. A summary of building types and climate zones is available for reference. Current versions are also available.

  16. Post Office Building, Rancho Mirage, California | Department...

    Energy Savers [EERE]

    Photo of Photovoltaic System at Rancho Mirage Post Office in California The U.S. Postal Service (USPS) has been making an effort to add solar power to its offices as part of the ...

  17. 2013 Building Technologies Office Program Peer Review Report

    SciTech Connect (OSTI)

    none,

    2013-11-01

    The 2013 Building Technologies Office Program Peer Review Report summarizes the results of the 2013 Building Technologies Office (BTO) peer review, which was held in Washington, D.C., on April 2–4, 2013. The review was attended by over 300 participants and included presentations on 59 BTO-funded projects: 29 from BTO’s Emerging Technologies Program, 20 from the Commercial Buildings Integration Program, 6 from the Residential Buildings Integration Program, and 4 from the Building Energy Codes Program. This report summarizes the scores and comments provided by the independent reviewers for each project.

  18. Archived Reference Building Type: Medium office

    Broader source: Energy.gov [DOE]

    Here you will find past versions of the commercial reference building models for existing buildings constructed before 1980, organized by building type and location. A summary ofbuilding types and climate zones is available for reference. Current versions are also available.

  19. Activity Stream - STIL2 Swedish Office Buildings Survey - Datasets...

    Open Energy Info (EERE)

    over 1 year ago Jay Huggins created the dataset STIL2 Swedish Office Buildings Survey over 1 year ago License License Not Specified Author Swedish Energy Agency Contact OpenEI User...

  20. Golden Reading Room: Office of Acquisition Documents, Better Buildings

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Initiative Support Services | Department of Energy Better Buildings Initiative Support Services Golden Reading Room: Office of Acquisition Documents, Better Buildings Initiative Support Services Below are electronic versions of Golden Field Office Reading Room documents that were created after November 1, 1996, per the requirements of the Electronic Freedom of Information Act Amendment of 1996. Most documents are available in Adobe Acrobat Portable Document Format (PDF). DE-SOL-0005538

  1. Building Technologies Office Overview - 2016 BTO Peer Review | Department

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    of Energy 6 BTO Peer Review Building Technologies Office Overview - 2016 BTO Peer Review Presenter: Roland Risser, U.S. Department of Energy This presentation at the 2016 Peer Review provided an overview of the Building Technologies Office. Through robust feedback, the BTO Program Peer Review enhances existing efforts and improves future designs. 2016 BTO Peer Review Presentation-Driving Innovation, Speeding Adoption, Scaling Savings (3.2 MB) More Documents & Publications Goals Framework

  2. Building Technologies Office 2015 Program Peer Review | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy 5 Program Peer Review Building Technologies Office 2015 Program Peer Review The 2015 Department of Energy (DOE) Building Technologies Office (BTO) Peer Review was held April 14-16, 2015 in Vienna, Virginia. This third annual review encompassed many of BTO's active research, development, demonstration and deployment projects. Independent experts assessed the progress and contributions of each project toward BTO's mission and goals, and these assessments will be used to enhance the

  3. Building Technologies Office 2016 Peer Review | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    6 Peer Review Building Technologies Office 2016 Peer Review The 2016 Department of Energy (DOE) Building Technologies Office (BTO) Peer Review was held April 4-7, 2016 in Falls Church, Virginia. This fourth annual review encompassed many of BTO's active research, development, demonstration and deployment projects. Independent experts assessed the progress and contributions of each project toward BTO's mission and goals, and these assessments will be used to enhance the management of existing

  4. Building Technologies Office Challenges National Labs to Rethink Market

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Engagement Strategy | Department of Energy Building Technologies Office Challenges National Labs to Rethink Market Engagement Strategy Building Technologies Office Challenges National Labs to Rethink Market Engagement Strategy December 10, 2015 - 2:21pm Addthis Karma Sawyer, Ph.D. Karma Sawyer, Ph.D. Acting Program Manager of Emerging Technologies What are the key facts? According to the U.S. Patent Office, only about 3,000 out of 1.5 million U.S. patents evaluated have resulted in a product

  5. Better Buildings Webinar Transcription- Financial Vehicles within an Integrated Energy Efficiency Program

    Broader source: Energy.gov [DOE]

    "Financial Vehicles Within an Integrated Energy Efficiency Program," webinar transcript from the U.S. Department of Energy's Better Buildings program.

  6. Office_of_Acquisition_and_Financial_Assessment.pdf

    Energy Savers [EERE]

    Department of Energy OfficeGovernmentEthicsGuidanceEthicsandProcurementIntegrity.pdf OfficeGovernmentEthicsGuidanceEthicsandProcurementIntegrity.pdf (2.33 MB) More Documents & Publications Office of Government Ethics Guidance, Ethics and Procurement Integrity POLICY FLASH 2016-04 Procurement Integrity

  7. Radiological Laboratory, Utility, Office Building LEED Strategy & Achievement

    SciTech Connect (OSTI)

    Seguin, Nicole R.

    2012-07-18

    Missions that the Radiological Laboratory, utility, Office Building (RLUOB) supports are: (1) Nuclear Materials Handling, Processing, and Fabrication; (2) Stockpile Management; (3) Materials and Manufacturing Technologies; (4) Nonproliferation Programs; (5) Waste Management Activities - Environmental Programs; and (6) Materials Disposition. The key capabilities are actinide analytical chemistry and material characterization.

  8. A generalized window energy rating system for typical office buildings

    SciTech Connect (OSTI)

    Tian, Cheng; Chen, Tingyao; Yang, Hongxing; Chung, Tse-ming

    2010-07-15

    Detailed computer simulation programs require lengthy inputs, and cannot directly provide an insight to relationship between the window energy performance and the key window design parameters. Hence, several window energy rating systems (WERS) for residential houses and small buildings have been developed in different countries. Many studies showed that utilization of daylight through elaborate design and operation of windows leads to significant energy savings in both cooling and lighting in office buildings. However, the current WERSs do not consider daylighting effect, while most of daylighting analyses do not take into account the influence of convective and infiltration heat gains. Therefore, a generalized WERS for typical office buildings has been presented, which takes all primary influence factors into account. The model includes embodied and operation energy uses and savings by a window to fully reflect interactions among the influence parameters. Reference locations selected for artificial lighting and glare control in the current common simulation practice may cause uncompromised conflicts, which could result in over- or under-estimated energy performance. Widely used computer programs, DOE2 and ADELINE, for hourly daylighting and cooling simulations have their own weaknesses, which may result in unrealistic or inaccurate results. An approach is also presented for taking the advantages of the both programs and avoiding their weaknesses. The model and approach have been applied to a typical office building of Hong Kong as an example to demonstrate how a WERS in a particular location can be established and how well the model can work. The energy effect of window properties, window-to-wall ratio (WWR), building orientation and lighting control strategies have been analyzed, and can be indicated by the localized WERS. An application example also demonstrates that the algebraic WERS derived from simulation results can be easily used for the optimal design of

  9. DOE standard compliance demonstration program: An office building example

    SciTech Connect (OSTI)

    Bailey, S.A.; Keller, J.M.; Wrench, L.E.; Williams, C.J.

    1993-06-01

    The US Department of Energy (DOE) issued interim new building energy standards (10 CFR 435 1989) to achieve maximum energy efficiency in the designs of new buildings. DOE then entered into a project to demonstrate and assess the impact of these standards on the design community. One area of focus was a test to see how a less conventional design-focused building would meet the standards` requirements -- DOE wanted to demonstrate that compliance with energy standards does not mean compromising the architectural intent of a building. This study, which was initiated at Pacific Northwest Laboratory (PNL), illustrated the process by which compliance with the standards can be proven for a highly {open_quotes}design-oriented{close_quotes} office building. The study also assessed the impact of the whole building simulation compliance alternatives on design. This report documents the compliance requirements, gives a description of the sample building chosen for the study, provides general guidance for the compliance process, documents the method of compliance that was undertaken for the sample building, presents the results of the study, and provides a recommendation on how the compliance requirements could be improved to reflect more realistic use types.

  10. Office of Building Technologies evaluation and planning report

    SciTech Connect (OSTI)

    Pierce, B.

    1994-06-01

    The US Department of Energy (DOE) Office of Building Technologies (OBT) encourages increased efficiency of energy use in the buildings sector through the conduct of a comprehensive research program, the transfer of research results to industry, and the implementation of DOE`s statutory responsibilities in the buildings area. The planning and direction of these activities require the development and maintenance of database and modeling capability, as well as the conduct of analyses. This report summarizes the results of evaluation and planning activities undertaken on behalf of OBT during the past several years. It provides historical data on energy consumption patterns, prices, and building characteristics used in OBT`s planning processes, and summaries of selected recent OBT analysis activities.

  11. Air exchange effectiveness in office buildings: Measurement techniques and results

    SciTech Connect (OSTI)

    Fisk, W.J.; Faulkner, D.

    1992-07-01

    We define two air exchange effectiveness parameters which indicate the extent of short circuiting, mixing, or displacement air flow in an entire building, the air diffusion effectiveness which indicates the air flow pattern locally, and the normalized local age of air. After describing two tracer gas procedures for measuring these parameters, we discuss assumptions inherent in the data analysis that are often violated in large office buildings. To obtain valuable data, careful selection of buildings for measurements and assessments to determine if operating conditions are reasonably consistent with the assumptions are necessary. Multiple factors, in addition to the air flow pattern in the occupied space, can affect measurement results, consequently, the interpretation of measurements is not straightforward. We summarize the results of measurements in several office buildings and in a research laboratory. Almost all measurements indicate that the extent of both short circuiting and displacement flow is small. A moderate amount of short circuiting is evident from a few measurements in rooms with heated supply air. Ages of air and their reciprocals (local ventilation rates) often vary substantially between rooms, probably because of room-to-room variation in the rate of air supply. For future research, we suggest assessments of measurement accuracy, development of measurement approaches that may be practically applied for a broader range of buildings, and a greater focus on pollutant removal efficiencies.

  12. Highlighting High Performance: Department of Environmental Protection; Cambria Office Building, Ebensburg, Pennsylvania

    SciTech Connect (OSTI)

    2001-11-01

    The 36,000-square-foot Cambria Office building used integrated design to minimize energy use, pollution and environmental impact the building will create over its lifetime.

  13. Building-related risk factors and work-related lower respiratory symptoms in 80 office buildings

    SciTech Connect (OSTI)

    Mendell, M.J.; Naco, G.M.; Wilcox, T.G.; Sieber, W.K.

    2002-01-01

    We assessed building-related risk factors for lower respiratory symptoms in office workers. The National Institute for Occupational Safety and Health in 1993 collected data during indoor environmental health investigations of workplaces. We used multivariate logistic regression analyses to assess relationships between lower respiratory symptoms in office workers and risk factors plausibly related to microbiologic contamination. Among 2,435 occupants in 80 office buildings, frequent, work-related multiple lower respiratory symptoms were strongly associated, in multivariate models, with two risk factors for microbiologic contamination: poor pan drainage under cooling coils and debris in outside air intake. Associations tended to be stronger among those with a history of physician-diagnosed asthma. These findings suggest that adverse lower respiratory health effects from indoor work environments, although unusual, may occur in relation to poorly designed or maintained ventilation systems, particularly among previously diagnosed asthmatics. These findings require confirmation in more representative buildings.

  14. Buildings Energy Data Book: 3.6 Office Building Markets and Companies

    Buildings Energy Data Book [EERE]

    5 Top 10 Office Building Owners Globally as of Year End, 2010 (million SF) Owner 1. RREEF Americas 2. Brookfield Properties Corp. 3. The Blackstone Group 4. CB Richard Ellis Investors 5. Hines 6. LaSalleInvestment Management 7. TIAA-CREF 8. Boston Properties 9. Vornado Realty Trust 10. Duke Realty Corp. Total for Top 10: Source(s): National Real Estate Investor, The 2011 Best of The Best Rankings: 2011 Top 25 Office Owners, June 1, 2011.

  15. Buildings Energy Data Book: 3.6 Office Building Markets and Companies

    Buildings Energy Data Book [EERE]

    2009 Energy Consumption per Square Foot of Office Floorspace by Vintage (Thousand Btu/SF) (1) Vintage 2000-2009 81.4 1990-1999 74.1 1980-1989 73.1 1970-1979 102.8 1960-1969 71.4 Pre-1959 75.5 Buildings providing consumption data: 436 Note(s): Source(s): Energy Intensity 1) Commercial office buildings sampled include the following: Class A, B, C. BOMA International, Experience Exchange Report 2010, 2010

  16. Building America Case Study: Quantifying the Financial Benefits...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Quantifying the Financial Benefits of Multifamily Retrofits Chicago, Illinois PROJECT INFORMATION Location: Chicago, IL Partners: Elevate Energy, elevateenergy.org Partnership for ...

  17. Buildings Energy Data Book: 3.6 Office Building Markets and Companies

    Buildings Energy Data Book [EERE]

    1 Energy Benchmarks for Newly Constructed Medium Office Buildings, by Selected City and End-Use (thousand Btu per square foot) Miami 1A Houston 2A Phoenix 2B Atlanta 3A Los Angeles 3B Las Vegas 3B San Francisco 3C Baltimore 4A Albuquerque 4B Seattle 4C Chicago 5A Boulder 5B Minneapolis 6A Helena 6B Duluth 7 Fairbanks 8 Note(s): Source(s): 38.6 0.9 0.8 1.1 Commercial building energy benchmarks are based off of the current stock of commercial buildings and reflect 2004 ASHRAE 90.1 Climate Zones.

  18. Buildings Energy Data Book: 3.6 Office Building Markets and Companies

    Buildings Energy Data Book [EERE]

    9 Energy Benchmarks for Newly Constructed Large Office Buildings, by Selected City and End-Use (thousand Btu per square foot) Miami 1A Houston 2A Phoenix 2B Atlanta 3A Los Angeles 3B Las Vegas 3B San Francisco 3C Baltimore 4A Albuquerque 4B Seattle 4C Chicago 5A Boulder 5B Minneapolis 6A Helena 6B Duluth 7 Fairbanks 8 Note(s): Source(s): 31.7 1.7 0.6 1.3 Commercial building energy benchmarks are based off of the current stock of commercial buildings and reflect 2004 ASHRAE 90.1 Climate Zones.

  19. Webinar: Impacts of Energy Efficiency on the Financial Performance of Commercial Buildings

    Broader source: Energy.gov [DOE]

    The Department of Energy conducted a review of existing market research on the impact of Energy Efficiency and Green Labels on building financial performance. This webinar will review the results...

  20. Pollution prevention opportunity assessment for Building 922 solid office waste

    SciTech Connect (OSTI)

    Phillips, N.M.

    1995-01-01

    Building 922 houses all of SNL/California`s ES and H Departments: Health Protection, Environmental Protection, Safety, and Environmental Operations. It covers approximately 10,000 square feet and houses about 80 people. The office personnel generate nonhazardous solid office wastes in their daily activities. To determine the types and amounts of waste generated, a special PPOA sorting team sorted all of the trash collected from the building for a period of one-week (including paper and aluminum cans in the recycling bins). The team sorted the trash into major categories: paper, plastic, metals, glass, wet garbage, rest room waste, and miscellaneous materials. They then sorted it into subcategories within each major category. Rest room waste was collected but not sorted. The waste in each category was weighed separately. The total amount of trash collected during the week was approximately 168.8 kg (371.4 lbs). The results of this PPOA indicate that SNL/California is minimizing most nonhazardous office waste and reductions planned for the near future will add significantly to the minimization efforts.

  1. March 2014 Office of Chief Financial Officer DOE/CF-0102 Budget...

    Energy Savers [EERE]

    ... FERC also reviews proposals to build liquefied natural gas (LNG) terminals as well as ... and storage projects, authorizing LNG facilities, and, in certain circumstances, ...

  2. Better Buildings Data and Summary Report - 2014 BTO Peer Review...

    Broader source: Energy.gov (indexed) [DOE]

    The purpose of this project is to collect data from organizations awarded financial ... This data is used to populate the Building Technologies Office's (BTO's) Buildings ...

  3. High-Performance Buildings – Value, Messaging, Financial and Policy Mechanisms

    SciTech Connect (OSTI)

    McCabe, Molly

    2011-02-22

    At the request of the Pacific Northwest National Laboratory, an in-depth analysis of the rapidly evolving state of real estate investments, high-performance building technology, and interest in efficiency was conducted by HaydenTanner, LLC, for the U.S. Department of Energy (DOE) Building Technologies Program. The analysis objectives were • to evaluate the link between high-performance buildings and their market value • to identify core messaging to motivate owners, investors, financiers, and others in the real estate sector to appropriately value and deploy high-performance strategies and technologies across new and existing buildings • to summarize financial mechanisms that facilitate increased investment in these buildings. To meet these objectives, work consisted of a literature review of relevant writings, examination of existing and emergent financial and policy mechanisms, interviews with industry stakeholders, and an evaluation of the value implications through financial modeling. This report documents the analysis methodology and findings, conclusion and recommendations. Its intent is to support and inform the DOE Building Technologies Program on policy and program planning for the financing of high-performance new buildings and building retrofit projects.

  4. Energy Savings Modeling of Standard Commercial Building Re-tuning Measures: Large Office Buildings

    SciTech Connect (OSTI)

    Fernandez, Nicholas; Katipamula, Srinivas; Wang, Weimin; Huang, Yunzhi; Liu, Guopeng

    2012-06-01

    Today, many large commercial buildings use sophisticated building automation systems (BASs) to manage a wide range of building equipment. While the capabilities of BASs have increased over time, many buildings still do not fully use the BAS's capabilities and are not properly commissioned, operated or maintained, which leads to inefficient operation, increased energy use, and reduced lifetimes of the equipment. This report investigates the energy savings potential of several common HVAC system retuning measures on a typical large office building prototype model, using the Department of Energy's building energy modeling software, EnergyPlus. The baseline prototype model uses roughly as much energy as an average large office building in existing building stock, but does not utilize any re-tuning measures. Individual re-tuning measures simulated against this baseline include automatic schedule adjustments, damper minimum flow adjustments, thermostat adjustments, as well as dynamic resets (set points that change continuously with building and/or outdoor conditions) to static pressure, supply air temperature, condenser water temperature, chilled and hot water temperature, and chilled and hot water differential pressure set points. Six combinations of these individual measures have been formulated - each designed to conform to limitations to implementation of certain individual measures that might exist in typical buildings. All of these measures and combinations were simulated in 16 cities representative of specific U.S. climate zones. The modeling results suggest that the most effective energy savings measures are those that affect the demand-side of the building (air-systems and schedules). Many of the demand-side individual measures were capable of reducing annual HVAC system energy consumption by over 20% in most cities that were modeled. Supply side measures affecting HVAC plant conditions were only modestly successful (less than 5% annual HVAC energy savings for

  5. Technical Support Document: 50% Energy Savings for Small Office Buildings

    SciTech Connect (OSTI)

    Thornton, Brian A.; Wang, Weimin; Huang, Yunzhi; Lane, Michael D.; Liu, Bing

    2010-04-30

    The Technical Support Document (TSD) for 50% energy savings in small office buildings documents the analysis and results for a recommended package of energy efficiency measures (EEMs) referred to as the advanced EEMs. These are changes to a building design that will reduce energy usage. The package of advanced EEMs achieves a minimum of 50% energy savings and a construction area weighted average energy savings of 56.6% over the ANSI/ASHRAE/IESNA Standard 90.1-2004 for 16 cities which represent the full range of climate zones in the United States. The 50% goal is for site energy usage reduction. The weighted average is based on data on the building area of construction in the various climate locations. Cost-effectiveness of the EEMs is determined showing an average simple payback of 6.7 years for all 16 climate locations. An alternative set of results is provided which includes a variable air volume HVAC system that achieves at least 50% energy savings in 7 of the 16 climate zones with a construction area weighted average savings of 48.5%. Other packages of EEMs may also achieve 50% energy savings; this report does not consider all alternatives but rather presents at least one way to reach the goal. Design teams using this TSD should follow an integrated design approach and utilize additional analysis to evaluate the specific conditions of a project.

  6. Chapter 5: Increasing Efficiency of Building Systems and Technologies | Building Technologies Office Potential Energy Savings Analysis Supplemental Information

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Roadmaps Building Technologies Office Potential Energy Savings Analysis ENERGY U.S. DEPARTMENT OF Quadrennial Technology Review 2015 1 Quadrennial Technology Review 2015 Building Technologies Office Potential Energy Savings Analysis Chapter 5: Supplemental Information Introduction The analysis undertaken to support Chapter 5 compares the potential energy savings from research, development, demonstration, and deployment (RDD&D) targets developed by the Department of Energy Building

  7. Building Technologies Office Program Peer Review April 2015

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... * ISO 50001: Conformant Energy Management Systems * Small Building Energy Management * BEM Library * Financing Turnkey Energy Efficiency Solutions * Better Buildings Challenge ...

  8. DOEs Building Technologies Office Technology-to-Market (T2M...

    Broader source: Energy.gov (indexed) [DOE]

    DOE Building Technologies Office (BTO) Ecosystem Clean Energy Innovation Infrastructure ... What does this model look like in BTO? * INFORM: - Utilize the BTO ecosystem to scope R&D ...

  9. Behavioral Opportunities for Energy Savings in Office Buildings: a London Field Experiment

    Broader source: Energy.gov [DOE]

    Report details a controlled field experiment to reduce energy use and greenhouse gas emissions in five organizations across four office buildings in London, England.

  10. Buildings Energy Data Book: 3.6 Office Building Markets and Companies

    Buildings Energy Data Book [EERE]

    7 Advanced Energy Design Guide for Small Office Buildings (1) Shell Percent Glass (WWR) 20-40% Window U-Factor 0.33-0.56 SHGC 0.31-0.49 Wall R-Value 7.6-15.2 Roof R-Value Attic 30-60 Insulation Above Deck 15-30 Wall Material Mass (HC > 7 Btu/ft^2) Lighting Average Power Density (Watts/SF) 0.9 System and Plant System and Plant Packaged Single-Zone Packaged Single-Zone w/ Economizer Cooling Capacity > 54 kBtu Heating Plant: Gas Furnace 80% Combustion Efficiency Cooling Plant: Air conditioner

  11. Buildings Energy Data Book: 3.6 Office Building Markets and Companies

    Buildings Energy Data Book [EERE]

    2 Energy Expenditures per Square Foot of Office Floorspace by Building Age ($2009) (1) Number of Number of Number of Age (years) 2009 Responses 2006 Responses 2004 Responses 0-9 2.1 451 2.1 483 1.8 564 10-19 1.9 582 2.3 503 2.0 848 20-29 2.1 1,161 2.4 939 2.0 786 30-39 2.4 416 2.7 314 2.3 290 40-49 2.5 150 3.0 68 2.9 57 50+ 2.5 187 2.5 128 2.1 164 All Buildings 2.2 3,494 2.4 2,619 1.8 2,939 Note(s): Source(s): 1) Energy includes electric, gas, fuel oil, purchased steam, purchased chilled water,

  12. Building Technologies Office FY 2017 Budget At-A-Glance | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy About Us » Building Technologies Office FY 2017 Budget At-A-Glance Building Technologies Office FY 2017 Budget At-A-Glance Buildings and homes use more than 73% of the electrical energy consumed in the United States. They also consume 40% of the nation's total energy, with an annual energy bill of $430 billion. These energy bills can be cost effectively reduced by 20%-50% or more through various energy-efficient technologies and techniques. The Building Technologies Office (BTO) will

  13. Energy-Saving Homes, Buildings, & Manufacturing (Fact Sheet), Office of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Efficiency and Renewable Energy, U.S. Department of Energy (DOE) | Department of Energy Energy-Saving Homes, Buildings, & Manufacturing (Fact Sheet), Office of Energy Efficiency and Renewable Energy, U.S. Department of Energy (DOE) Energy-Saving Homes, Buildings, & Manufacturing (Fact Sheet), Office of Energy Efficiency and Renewable Energy, U.S. Department of Energy (DOE) This document highlights DOE's Office of Energy Efficiency and Renewable Energy's advancements in saving

  14. Technical Support Document: 50% Energy Savings Design Technology Packages for Medium Office Buildings

    SciTech Connect (OSTI)

    Thornton, Brian A.; Wang, Weimin; Lane, Michael D.; Rosenberg, Michael I.; Liu, Bing

    2009-09-01

    This Technical Support Document (TSD) describes the process and methodology for development of the Advanced Energy Design Guide for Medium Offices (AEDG-MO or the Guide), a design guidance document which intends to provide recommendations for achieving 50% energy savings in medium office buildings that just meet the requirements of ANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings.

  15. Supervisory Financial Analyst

    Broader source: Energy.gov [DOE]

    (See Frequently Asked Questions for more information). Where would I be working? Western Area Power Administration, Corporate Services Office, Office of the Chief Financial Officer, Financial...

  16. Highlighting High Performance: Department of Environmental Protection; Cambria Office Building, Ebensburg, Pennsylvania

    SciTech Connect (OSTI)

    Not Available

    2001-10-01

    The 36,000-square-foot Cambria Office building in Ebensbug, Pennsylvania houses the Pennsylvania Department of Environmental Protection. Designers of the energy-efficient building used integrated design to minimize energy use and pollution created in the production of the materials they used, and reduced the overall pollution and environmental impact the building will create over its lifetime. The building also employs daylighting and renewable energy technologies.

  17. Office of Building Technology, State and Community Programs Strategic Plan

    SciTech Connect (OSTI)

    None, None

    2009-01-18

    This is the strategic plan for the Building Technology Program in 1998. This describes trends in the BTP program and projects goals for the future.

  18. Preliminary Energy Analysis of the Pennsylvania Department of Environmental Protection's Cambria Office Building Ebensburg, PA

    SciTech Connect (OSTI)

    Deru, M.; Hancock, E.

    2003-01-01

    The Pennsylvania Department of Environmental Protection (DEP) has undertaken a path to build''high performance green'' buildings as part of the objectives of the Governors Green Government Council. The first building, completed in 1998, is used as the DEPs regional headquarters in Harrisburg. The Cambria office, located in Ebensburg, is DEPs second building. Many of the lessons learned from the first building were successfully applied to this building, which was completed in 2000. The objective was to provide a comfortable and productive work environment while minimizing its short- and long-term environmental impacts.

  19. Building Technologies Office FY 2015 Budget At-A-Glance | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy 5 Budget At-A-Glance Building Technologies Office FY 2015 Budget At-A-Glance Buildings use more than 70% of the electrical energy consumed in the United States. Homes and commercial buildings consume 40% of the nation's total energy with an annual energy bill of more than $400 billion. These energy bills can be cost-effectively reduced by 20-50% or more through various energy efficiency technologies and techniques. The Building Technologies Office will continue to develop and

  20. Building Technologies Office: R&D Opportunities to Reduce Energy...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Office: R&D Opportunities to Reduce Energy Consumption in Miscellaneous Electric Loads ... Why Do We Care About MELs? Problem: Fraction of energy consumption due to MELs is rising ...

  1. Reducing Data Center Loads for a Large-Scale, Net Zero Office Building |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy Reducing Data Center Loads for a Large-Scale, Net Zero Office Building Reducing Data Center Loads for a Large-Scale, Net Zero Office Building Document describes the design, implementation strategies, and continuous performance monitoring of the National Renewable Energy Laboratory's Research Support Facility data center. Download the case study. (3.03 MB) More Documents & Publications Top ECMs for Labs and Data Centers Best Practices Guide for Energy-Efficient Data

  2. Attendees: John Cymbalsky, Equipment and Appliance Standards Program Manager, Building Technologies Office,

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Lutron ex-parte meeting at DOE Pekka Hakkarainen 11 February 2015 Page 1 of 4 Lutron Electronics Co., Inc. ex-parte meeting at the U.S. Department of Energy Subject: LED drivers are not external power supplies Meeting date: 11 February 2015 Attendees: John Cymbalsky, Equipment and Appliance Standards Program Manager, Building Technologies Office, DOE Jeremy Dommu, Project Manager, Equipment and Appliance Standards Program, Building Technologies Office, DOE Laura Barhydt, Assistant General

  3. USDOE energy standard compliance test on two-story office building

    SciTech Connect (OSTI)

    Bailey, S.A.

    1993-11-01

    There exists some skepticism in the design community regarding the ability to design an aesthetically pleasing building that meets the interim energy conservation standard for new commercial buildings initiated by the US Department of Energy. In response to this, a study was undertaken to demonstrate that compliance with energy standards does not mean giving up the architectural intent of a building. An unusual and architecturally pleasing building design was chosen for this study. This two-story office building has a large, central atrium, made almost entirely of glass. It is the building`s focal point, lending an inviting atmosphere to the interior spaces but also poses a considerable challenge to the HVAC system to keep the building comfortable. The building was simulated and easily complied with the Standard, based on an annual energy cost comparison. Alterations to the original design affected neither the interior floor plan nor exterior elevations.

  4. DOE Building Technologies Office seeks science and engineering...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Deadline for applying is Nov. 15, 2015, at 11:59 p.m. EST FOR IMMEDIATE RELEASE Nov. 9, ... The deadline for applying is Nov. 15, at 11:59 p.m. EST. The Building-Grid Integration ...

  5. Buildings Energy Data Book: 3.6 Office Building Markets and Companies

    Buildings Energy Data Book [EERE]

    0 Energy Benchmarks for Existing Medium Office Buildings, by Selected City and End-Use (thousand Btu per square foot) IECC Post Pre Post Pre Post Pre Post Pre Miami 1A 1.0 0.0 22.0 19.2 0.4 0.4 1.9 13.0 Houston 2A 4.6 1.8 15.5 14.7 0.5 0.5 1.5 12.8 Phoenix 2B 4.0 0.7 17.5 19.4 0.4 0.4 1.9 15.0 Atlanta 3A 7.8 4.3 10.1 10.4 0.6 0.5 1.4 13.9 Los Angeles 3B 4.1 0.3 8.0 3.5 0.5 0.5 1.4 10.9 Las Vegas 3B 5.6 1.4 13.2 14.6 0.5 0.5 1.8 14.5 San Francisco 3C 5.8 1.7 2.9 1.2 0.6 0.6 1.1 8.9 Baltimore 4A

  6. Buildings Energy Data Book: 3.6 Office Building Markets and Companies

    Buildings Energy Data Book [EERE]

    8 Energy Benchmarks for Existing Large Office Buildings, by Selected City and End-Use (thousand Btu per square foot) IECC Post Pre Post Pre Post Pre Post Pre Miami 1A 0.3 0.8 21.9 24.5 0.3 0.2 3.1 3.5 Houston 2A 4.2 4.4 17.7 20.9 0.3 0.3 2.8 3.3 Phoenix 2B 3.0 3.3 16.2 18.3 0.3 0.3 3.2 3.7 Atlanta 3A 6.9 8.5 14.1 17.5 0.4 0.4 2.6 3.2 Los Angeles 3B 2.8 2.9 11.9 13.0 0.4 0.4 2.5 2.7 Las Vegas 3B 4.6 4.7 10.8 13.0 0.3 0.3 2.7 3.3 San Francisco 3C 5.0 6.4 5.6 6.6 0.4 0.4 1.8 2.1 Baltimore 4A 9.8

  7. Office | Open Energy Information

    Open Energy Info (EERE)

    Office Jump to: navigation, search Building Type Office Definition Buildings used for general office space, professional office, or administrative offices. Medical offices are...

  8. Building Technologies Office FY 2016 Budget At-A-Glance | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy 6 Budget At-A-Glance Building Technologies Office FY 2016 Budget At-A-Glance Buildings and homes use more than 73% of the electrical energy consumed in the United States. They also consume 40% of the nation's total energy, with an annual energy bill of $430 billion. These energy bills can be cost effectively reduced by 20%-50% or more through various energy-efficient technologies and techniques. The Building Technologies Office (BTO) will continue to develop and demonstrate advanced

  9. On Variations of Space-heating Energy Use in Office Buildings

    SciTech Connect (OSTI)

    Lin, Hung-Wen; Hong, Tianzhen

    2013-05-01

    Space heating is the largest energy end use, consuming more than 7 quintillion joules of site energy annually in the U.S. building sector. A few recent studies showed discrepancies in simulated space-heating energy use among different building energy modeling programs, and the simulated results are suspected to be underpredicting reality. While various uncertainties are associated with building simulations, especially when simulations are performed by different modelers using different simulation programs for buildings with different configurations, it is crucial to identify and evaluate key driving factors to space-heating energy use in order to support the design and operation of low-energy buildings. In this study, 10 design and operation parameters for space-heating systems of two prototypical office buildings in each of three U.S. heating climates are identified and evaluated, using building simulations with EnergyPlus, to determine the most influential parameters and their impacts on variations of space-heating energy use. The influence of annual weather change on space-heating energy is also investigated using 30-year actual weather data. The simulated space-heating energy use is further benchmarked against those from similar actual office buildings in two U.S. commercial-building databases to better understand the discrepancies between simulated and actual energy use. In summary, variations of both the simulated and actual space-heating energy use of office buildings in all three heating climates can be very large. However these variations are mostly driven by a few influential parameters related to building design and operation. The findings provide insights for building designers, owners, operators, and energy policy makers to make better decisions on energy-efficiency technologies to reduce space-heating energy use for both new and existing buildings.

  10. Building Technologies Office (BTO) Sensors and Controls Technologies

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Sensors and Controls Technologies Emerging Technologies R&D Program Marina Sofos, Ph.D. marina.sofos@ee.doe.gov 2 BTO Emerging Technologies R&D Goals As a result of ET sponsored research, cost effective technologies will be introduced into the marketplace by 2020 that will be capable of reducing a building's energy use by 25% relative to 2010 cost effective technologies, and 35% by 2030. Technology-specific targets relative to the 2030 primary energy consumption projected by the 2010

  11. Grand Junction Projects Office Remedial Action Project Building 2 public dose evaluation. Final report

    SciTech Connect (OSTI)

    Morris, R.

    1996-05-01

    Building 2 on the U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) site, which is operated by Rust Geotech, is part of the GJPO Remedial Action Program. This report describes measurements and modeling efforts to evaluate the radiation dose to members of the public who might someday occupy or tear down Building 2. The assessment of future doses to those occupying or demolishing Building 2 is based on assumptions about future uses of the building, measured data when available, and predictive modeling when necessary. Future use of the building is likely to be as an office facility. The DOE sponsored program, RESRAD-BUILD, Version. 1.5 was chosen for the modeling tool. Releasing the building for unrestricted use instead of demolishing it now could save a substantial amount of money compared with the baseline cost estimate because the site telecommunications system, housed in Building 2, would not be disabled and replaced. The information developed in this analysis may be used as part of an as low as reasonably achievable (ALARA) cost/benefit determination regarding disposition of Building 2.

  12. A Prospective Study of Ventilation Rates and Illness Absence in California Office Buildings

    SciTech Connect (OSTI)

    Eliseeva, Ekaterina A.; Spears, Michael; Chan, Wanyu R.; Cohn, Sebastian; Sullivan, Douglas P.; Fisk, William J.

    2014-10-07

    Background – This study investigated the associations of ventilation rates (VRs), estimated from indoor CO2 concentrations, in offices with the amount of respiratory infections, illness absences, and building-related health symptoms in occupants. Methods – Office buildings were recruited from three California climate zones. In one or more study spaces within each building, real-time logging sensors measured carbon dioxide, temperature, and relative humidity for one year. Ventilation rates were estimated using daily peak CO2 levels, and also using an alternative metric. Data on occupants and health outcomes were collected through web-based surveys every three months. Multivariate models were used to assess relationships between metrics of ventilation rate or CO2 and occupant outcomes. For all outcomes, negative associations were hypothesized with VR metrics, and positive associations with CO2 metrics. Results – Difficulty recruiting buildings and low survey response limited sample size and study power. In 16 studied spaces within 9 office buildings, VRs were uniformly high over the year, from twice to over nine times the California office VR standard (7 L/s or 15 cfm per person). VR and CO2 metrics had no statistically significant relationships with occupant outcomes, except for a small significantly positive association of the alternative VR metric with respiratory illness-related absence, contrary to hypotheses. Conclusions– The very high time-averaged VRs in the California office buildings studied presumably resulted from “economizer cycles” bringing in large volumes of outdoor air; however, in almost all buildings even the estimated minimum VRs supplied (without the economizer) substantially exceeded the minimum required VR. These high VRs may explain the absence of hypothesized relationships with occupant outcomes. Among uniformly high VRs, little variation in contaminant concentration and occupant effects would be expected. These findings may

  13. MEMORANDUM TO: John Cymbalsky, U.S. Department of Energy, Office of Building

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    MEMORANDUM TO: John Cymbalsky, U.S. Department of Energy, Office of Building Technologies FROM: Ginger Willson, Director, Nebraska Energy Office DATE: December 12, 2011 RE: Meeting regarding DOE Energy Conservations Standards for Battery Chargers Following the Friday, December 2, 2011 meeting, please find below participants and discussion points presented relating to the U.S. Department of Energy (DOE) Energy Conservation Standards for Battery Chargers. The following participated in the meeting:

  14. Energy and Cost Savings of Retro-Commissioning and Retrofit Measures for Large Office Buildings

    SciTech Connect (OSTI)

    Wang, Weimin; Zhang, Jian; Moser, Dave; Liu, Guopeng; Athalye, Rahul A.; Liu, Bing

    2012-08-03

    This paper evaluates the energy and cost savings of seven retro-commissioning measures and 29 retrofit measures applicable to most large office buildings. The baseline model is for a hypothetical building with characteristics of large office buildings constructed before 1980. Each retro-commissioning measure is evaluated against the original baseline in terms of its potential of energy and cost savings while each retrofit measure is evaluated against the commissioned building. All measures are evaluated in five locations (Miami, Las Vegas, Seattle, Chicago and Duluth) to understand the impact of weather conditions on energy and cost savings. The results show that implementation of the seven operation and maintenance measures as part of a retro-commissioning process can yield an average of about 22% of energy use reduction and 14% of energy cost reduction. Widening zone temperature deadband, lowering VAV terminal minimum air flow set points and lighting upgrades are effective retrofit measures to be considered.

  15. Estimating Total Energy Consumption and Emissions of China's Commercial and Office Buildings

    SciTech Connect (OSTI)

    Fridley, David; Fridley, David G.; Zheng, Nina; Zhou, Nan

    2008-03-01

    Buildings represent an increasingly important component of China's total energy consumption mix. However, accurately assessing the total volume of energy consumed in buildings is difficult owing to deficiencies in China's statistical collection system and a lack of national surveys. Official statistics suggest that buildings account for about 19% of China's total energy consumption, while others estimate the proportion at 23%, rising to 30% over the next few years. In addition to operational energy, buildings embody the energy used in the in the mining, extraction, harvesting, processing, manufacturing and transport of building materials as well as the energy used in the construction and decommissioning of buildings. This embodied energy, along with a building's operational energy, constitutes the building's life-cycle energy and emissions footprint. This report first provides a review of international studies on commercial building life-cycle energy use from which data are derived to develop an assessment of Chinese commercial building life-cycle energy use, then examines in detail two cases for the development of office building operational energy consumption to 2020. Finally, the energy and emissions implications of the two cases are presented.

  16. Characterizing Indoor Airflow and Pollutant Transport using Simulation Modeling for Prototypical Buildings. I. Office Buildings

    SciTech Connect (OSTI)

    Sohn, M.D.; Daisey, J.M.; Feustel, H.E.

    1999-06-01

    This paper describes the first efforts at developing a set of prototypical buildings defined to capture the key features affecting airflow and pollutant transport in buildings. These buildings will be used to model airflow and pollutant transport for emergency response scenarios when limited site-specific information is available and immediate decisions must be made, and to better understand key features of buildings controlling occupant exposures to indoor pollutant sources. This paper presents an example of this approach for a prototypical intermediate-sized, open style, commercial building. Interzonal transport due to a short-term source release, e.g., accidental chemical spill, in the bottom and the upper floors is predicted and corresponding HVAC system operation effects and potential responses are considered. Three-hour average exposure estimates are used to compare effects of source location and HVAC operation.

  17. Health-hazard evaluation report HETA 86-434-1833, Federal Office Building, Evansville, Indiana

    SciTech Connect (OSTI)

    Bryant, C.J.

    1987-09-01

    An evaluation was made of potential asbestos exposure in the Federal Office Building located in Evansville, Indiana. Several surface samples revealed chrysotile and amosite fibers which indicated a history of past airborne asbestos at the site. The author concluded that a potential health hazard exists. It is recommended that the material be safely removed by a reliable contractor skilled in asbestos abatement. Interim precautionary measures are suggested to allow for building use until the asbestos is completely removed.

  18. NIOSH (National Institute for Occupational Safety and Health) indoor air quality in office buildings

    SciTech Connect (OSTI)

    Wallingford, K.M.

    1987-01-01

    A total of 356 indoor-air-quality health-hazard evaluations were completed by NIOSH from 1971 through December of 1985. Most of these studies concerned government and private office buildings where there were worker complaints. Worker complaints resulted from contamination from inside the building (19% of the cases), contamination from outside (11 percent), contamination from the building fabric (4%), biological contamination (5%), inadequate ventilation (50%), and unknown causes (11%). Health complaints addressed by investigative efforts included eye irritation, dry throat, headache, fatigue, sinus congestion, skin irritation, shortness of breath, cough, dizziness, and nausea.

  19. Revealing Occupancy Patterns in Office Buildings Through the use of Annual Occupancy Sensor Data

    SciTech Connect (OSTI)

    Carlos Duarte; Kevin Van Den Wymelenberg; Craig Rieger

    2013-06-01

    Energy simulation programs like DOE-2 and EnergyPlus are tools that have been proven to aid with energy calculations to predict energy use in buildings. Some inputs to energy simulation models are relatively easy to find, including building size, orientation, construction materials, and HVAC system size and type. Others vary with time (e.g. weather and occupancy) and some can be a challenge to estimate in order to create an accurate simulation. In this paper, the analysis of occupancy sensor data for a large commercial, multi-tenant office building is presented. It details occupancy diversity factors for private offices and summarizes the same for open offices, hallways, conference rooms, break rooms, and restrooms in order to better inform energy simulation parameters. Long-term data were collected allowing results to be presented to show variations of occupancy diversity factors in private offices for time of day, day of the week, holidays, and month of the year. The diversity factors presented differ as much as 46% from those currently published in ASHRAE 90.1 2004 energy cost method guidelines, a document referenced by energy modelers regarding occupancy diversity factors for simulations. This may result in misleading simulation results and may introduce inefficiencies in the final equipment and systems design.

  20. Revealing Occupancy Patterns in an Office Building through the Use of Occupancy Sensor Data

    SciTech Connect (OSTI)

    Carlos Duarte; Kevin Van Den Wymelenberg; Craig Rieger

    2013-12-01

    Energy simulation programs like DOE-2 and EnergyPlus are tools that have been proven to aid with energy calculations to predict energy use in buildings. Some inputs to energy simulation models are relatively easy to find, including building size, orientation, construction materials, and HVAC system size and type. Others vary with time (e.g. weather and occupancy) and some can be a challenge to estimate in order to create an accurate simulation. In this paper, the analysis of occupancy sensor data for a large commercial, multi-tenant office building is presented. It details occupancy diversity factors for private offices and summarizes the same for open offices, hallways, conference rooms, break rooms, and restrooms in order to better inform energy simulation parameters. Long-term data were collected allowing results to be presented to show variations of occupancy diversity factors in private offices for time of day, day of the week, holidays, and month of the year. The diversity factors presented differ as much as 46% from those currently published in ASHRAE 90.1 2004 energy cost method guidelines, a document referenced by energy modelers regarding occupancy diversity factors for simulations. This may result in misleading simulation results and may introduce inefficiencies in the final equipment and systems design.

  1. Plug-Load Control and Behavioral Change Research in GSA Office Buildings

    SciTech Connect (OSTI)

    Metzger, I.; Cutler, D.; Sheppy, M.

    2012-10-01

    The U.S. General Services Administration (GSA) owns and leases over 354 million square feet (ft2) of space in over 9,600 buildings [1]. GSA is a leader among federal agencies in aggressively pursuing energy efficiency (EE) opportunities for its facilities and installing renewable energy (RE) systems to provide heating, cooling, and power to these facilities. According to several energy assessments of GSA's buildings conducted by the National Renewable Energy Laboratory (NREL), plug-loads account for approximately 21% of the total electricity consumed within a standard GSA Region 3 office building. This study aims to provide insight on how to effectively manage plug-load energy consumption and attain higher energy and cost savings for plug-loads. As GSA improves the efficiency of its building stock, plug-loads will become an even greater portion of its energy footprint.

  2. DOE/ NREL Build One of the World's Most Energy Efficient Office Spaces

    ScienceCinema (OSTI)

    None

    2013-05-29

    Technology ? from sophisticated computer modeling to advanced windows that actually open ? will help the newest building at the U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) be one of the world's most energy efficient offices. Scheduled to open this summer, the 222,000 square-foot RSF will house more than 800 staff and an energy efficient information technology data center. Because 19 percent of the country's energy is used by commercial buildings, DOE plans to make this facility a showcase for energy efficiency. DOE hopes the design of the RSF will be replicated by the building industry and help reduce the nation's energy consumption by changing the way commercial buildings are designed and built.

  3. Energy Savings Modelling of Re-tuning Energy Conservation Measures in Large Office Buildings

    SciTech Connect (OSTI)

    Fernandez, Nicholas; Katipamula, Srinivas; Wang, Weimin; Huang, Yunzhi; Liu, Guopeng

    2014-10-20

    Today, many large commercial buildings use sophisticated building automation systems (BASs) to manage a wide range of building equipment. While the capabilities of BASs have increased over time, many buildings still do not fully use the BASs capabilities and are not properly commissioned, operated or maintained, which leads to inefficient operation, increased energy use, and reduced lifetimes of the equipment. This paper investigates the energy savings potential of several common HVAC system re-tuning measures on a typical large office building, using the Department of Energys building energy modeling software, EnergyPlus. The baseline prototype model uses roughly as much energy as an average large office building in existing building stock, but does not utilize any re-tuning measures. Individual re-tuning measures simulated against this baseline include automatic schedule adjustments, damper minimum flow adjustments, thermostat adjustments, as well as dynamic resets (set points that change continuously with building and/or outdoor conditions) to static pressure, supply-air temperature, condenser water temperature, chilled and hot water temperature, and chilled and hot water differential pressure set points. Six combinations of these individual measures have been formulated each designed to conform to limitations to implementation of certain individual measures that might exist in typical buildings. All the individual measures and combinations were simulated in 16 climate locations representative of specific U.S. climate zones. The modeling results suggest that the most effective energy savings measures are those that affect the demand-side of the building (air-systems and schedules). Many of the demand-side individual measures were capable of reducing annual total HVAC system energy consumption by over 20% in most cities that were modeled. Supply side measures affecting HVAC plant conditions were only modestly successful (less than 5% annual HVAC energy

  4. Cooling season performance of an earth-sheltered office/dormitory building in Oak Ridge, Tennessee

    SciTech Connect (OSTI)

    Christian, J.E.

    1984-07-01

    Detailed hourly measurements taken in and around an underground office-dormitory building for two summers document energy savings; whole building-component interface problems; and specific cooling contributions from earth contact, interior thermal mass, and an economizer. The Joint Institute Dormitory (JID) saves about 30% compared with well-built above-grade buildings in a climate typical of Oak Ridge, Tennessee, and has the potential to save as much as 50%. The detailed measurements, which include extensive thermal comfort data, indicate that at least 90% of the occupants are comfortable all of the time. The thermal performance measurements and analysis determine that the peak cooling requirement of this building is 50% less than that of well-built above-grade structures, permitting a cost savings on installed cooling capacity. The dominant building components contributing to the good thermal performance are the structural thermal mass, the earth-covered roof, and the earth contact provided by the bermed walls and slab floor. The 372-m/sup 2/ (4000 gross ft/sup 2/) building used about $300 (at 5.7 cents/kWh) to cool and ventilate from May through September. Eliminating a number of building design and construction anomalies could improve the whole-building performance and reduce the seasonal cooling cost another $85. Close examination of the thermal performance of this building revealed that a very efficient heat pump and thermally sound envelope do not necessarily produce otpimum performance without careful attention given to component interface details. 8 references, 24 figures, 12 tables.

  5. Final Project Report for DPD, Inc. Office Building in Lansing, Michigan

    SciTech Connect (OSTI)

    Deru, M.; Sherman, M.

    2003-03-01

    The National Renewable Energy Laboratory participated with DPD, Inc., in the thermal analysis of buildings constructed using concrete with recycled materials in the aggregate. This project was part of a Phase II Small Business Innovative Research grant to determine how the thermal properties of concrete can be''tuned'' for use in passive solar buildings. DPD Inc. and Michigan State University developed techniques to alter the thermal properties of concrete by introducing recycled materials into the aggregate. Two office/retail buildings were built in Lansing, Michigan for this research. The objective of NREL's involvement was to evaluate the effects of concrete thermal properties on the building performance through energy simulations and monitoring. This report presents a summary of work accomplished on this project, including a predesign analysis of the concrete properties and building designs as well as energy performance analysis after construction. The test results were used to calibrate computer models that were later used to predict long-term performance of the buildings.

  6. Technical basis for radiological release of Grand Junction Office Building 2. Volume 1, dose assessment

    SciTech Connect (OSTI)

    Morris, R.; Warga, J.; Thorne, D.

    1997-07-01

    Building 2 on the US Department of Energy (DOE) Grand Junction Office (GJO) site is part of the GJO Remedial Action Program (GJORAP). During evaluation of Building 2 for determination of radiological release disposition, some inaccessible surface contamination measurements were detected to be greater than the generic surface contamination guidelines of DOE Order 5400.5 (which are functionally equivalent to US Nuclear Regulatory Commission [NRC] Regulatory Guide 1.86). Although the building is nominal in size, it houses the site telecommunications system, that is critical to continued GJO operations, and demolition is estimated at $1.9 million. Because unrestricted release under generic surface contamination guidelines is cost-prohibitive, supplemental standards consistent with DOE Order 5400.5 are being pursued. This report describes measurements and dose analysis modeling efforts to evaluate the radiation dose to members of the public who might occupy or demolish Building 2, a 2,480 square-foot (ft) building constructed in 1944. The north portion of the building was used as a shower facility for Manhattan Project uranium-processing mill workers and the south portion was a warehouse. Many originally exposed surfaces are no longer accessible for contamination surveys because expensive telecommunications equipment have been installed on the floors and mounted on panels covering the walls. These inaccessible surfaces are contaminated above generic contamination limits.

  7. Design and testing of a control strategy for a large naturallyventilated office building

    SciTech Connect (OSTI)

    Carrilho da Graca, Guilherme; Linden, Paul F.; Haves, Philip

    2004-03-16

    The design for the new Federal Building for San Franciscoincludes an office tower that is to be naturally ventilated. Each flooris designed to be cross-ventilated, through upper windows that arecontrolled by the building management system (BMS). Users have controlover lower windows, which can be as much as 50 percent of the totalopenable area. There are significant differences in the performance andthe control of the windward and leeward sides of the building, andseparate monitoring and control strategies are determined for each side.The performance and control of the building has been designed and testedusing a modified version of EnergyPlus. Results from studies withEnergyPlus and CFD are used in designing the control strategy. EnergyPluswas extended to model a simplified version of the airflow patterndetermined using CFD. Wind-driven cross-ventilation produces a main jetthrough the upper openings of the building, across the ceiling from thewindward to the leeward side. Below this jet, the occupied regions aresubject to a recirculating air flow. Results show that temperatureswithin the building are predicted to be satisfactory, provided a suitablecontrol strategy is implemented uses night cooling in periods of hotweather. The control strategy has 10 window opening modes. EnergyPlus wasextended to simulate the effects of these modes, and to assess theeffects of different forms of user behavior. The results show how userbehavior can significantly influence the buildingperformance.

  8. Targeted Energy Efficiency Expert Evaluation (E4) Report: Iowa City Federal Building and U.S. Post Office, Iowa City, IA

    SciTech Connect (OSTI)

    Goddard, James K.; Fernandez, Nicholas; Underhill, Ronald M.; Gowri, Krishnan

    2013-03-01

    Final report summarizing Targeted E4 measures and energy savings analysis for the Iowa City Federal Building and Post Office.

  9. Letter to Congress RE: Office of Civilian Radioactive Waste Management's Annual Financial Report

    Broader source: Energy.gov [DOE]

    The following document is a letter from the Secretary of Energy to the Honorable Joseph R. Biden regarding the U.S. Department of Energy's Office of Civilian Radioactive Waste Management's Annual...

  10. Final report of the radiological release survey of Building 11 at the Grand Junction Office Facility

    SciTech Connect (OSTI)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 11 and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building.

  11. Final report of the radiological release survey of Building 19 at the Grand Junction Office Facility

    SciTech Connect (OSTI)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 19 and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building.

  12. Final report of the radiological release survey of Building 29 at the Grand Junction Office Facility

    SciTech Connect (OSTI)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailing during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 29 and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building.

  13. Radiant cooling in US office buildings: Towards eliminating the perception of climate-imposed barriers

    SciTech Connect (OSTI)

    Stetiu, C.

    1998-01-01

    Much attention is being given to improving the efficiency of air-conditioning systems through the promotion of more efficient cooling technologies. One such alternative, radiant cooling, is the subject of this thesis. Performance information from Western European buildings equipped with radiant cooling systems indicates that these systems not only reduce the building energy consumption but also provide additional economic and comfort-related benefits. Their potential in other markets such as the US has been largely overlooked due to lack of practical demonstration, and to the absence of simulation tools capable of predicting system performance in different climates. This thesis describes the development of RADCOOL, a simulation tool that models thermal and moisture-related effects in spaces equipped with radiant cooling systems. The thesis then conducts the first in-depth investigation of the climate-related aspects of the performance of radiant cooling systems in office buildings. The results of the investigation show that a building equipped with a radiant cooling system can be operated in any US climate with small risk of condensation. For the office space examined in the thesis, employing a radiant cooling system instead of a traditional all-air system can save on average 30% of the energy consumption and 27% of the peak power demand due to space conditioning. The savings potential is climate-dependent, and is larger in retrofitted buildings than in new construction. This thesis demonstrates the high performance potential of radiant cooling systems across a broad range of US climates. It further discusses the economics governing the US air-conditioning market and identifies the type of policy interventions and other measures that could encourage the adoption of radiant cooling in this market.

  14. Technical Support Document: Strategies for 50% Energy Savings in Large Office Buildings

    SciTech Connect (OSTI)

    Leach, M.; Lobato, C.; Hirsch, A.; Pless, S.; Torcellini, P.

    2010-09-01

    This Technical Support Document (TSD) documents technical analysis that informs design guidance for designing and constructing large office buildings that achieve 50% net site energy savings over baseline buildings defined by minimal compliance with respect to ANSI/ASHRAE/IESNA Standard 90.1-2004. This report also represents a step toward developing a methodology for using energy modeling in the design process to achieve aggressive energy savings targets. This report documents the modeling and analysis methods used to identify design recommendations for six climate zones that capture the range of U.S. climate variability; demonstrates how energy savings change between ASHRAE Standard 90.1-2007 and Standard 90.1-2004 to determine baseline energy use; uses a four-story 'low-rise' prototype to analyze the effect of building aspect ratio on energy use intensity; explores comparisons between baseline and low-energy building energy use for alternate energy metrics (net source energy, energy emissions, and energy cost); and examines the extent to which glass curtain construction limits achieve energy savings by using a 12-story 'high-rise' prototype.

  15. Final report of the radiological release survey of Building 54 at the Grand Junction Office Facility

    SciTech Connect (OSTI)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 54 and the underlying soil were found not to be radiologically contaminated, and can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual release report for each GJO building.

  16. Reducing Plug and Process Loads for a Large Scale, Low Energy Office Building: NREL's Research Support Facility; Preprint

    SciTech Connect (OSTI)

    Lobato, C.; Pless, S.; Sheppy, M.; Torcellini, P.

    2011-02-01

    This paper documents the design and operational plug and process load energy efficiency measures needed to allow a large scale office building to reach ultra high efficiency building goals. The appendices of this document contain a wealth of documentation pertaining to plug and process load design in the RSF, including a list of equipment was selected for use.

  17. Energy Department Announces $9 Million to Improve Energy Efficiency of Hotels, Hospitals, Offices and other Commercial Buildings

    Broader source: Energy.gov [DOE]

    As part of the Obama Administration’s effort to double energy productivity by 2030 and reduce carbon emissions in commercial buildings, the Energy Department today announced $9 million to encourage investments in energy-saving technologies that can be tested and deployed in offices, shops, restaurants, hospitals, hotels and other types of commercial buildings.

  18. Energy Department Invests $6 Million to Increase Energy Efficiency of Schools, Offices, Stores and other U.S. Buildings

    Broader source: Energy.gov [DOE]

    As part of the Administration’s effort to cut energy waste in the nation’s buildings and double energy productivity by 2030, the Energy Department today announced nearly $6 million to accelerate energy efficiency in offices, shops, schools and other buildings that will help businesses and communities save money, create jobs, and reduce pollution.

  19. Potential energy savings with exterior shades in large office buildings and the impact of discomfort glare

    SciTech Connect (OSTI)

    Hoffmann, Sabine; Lee, Eleanor

    2015-04-01

    Exterior shades are highly efficient for reducing solar load in commercial buildings. Their impact on net energy use depends on the annual energy balance of heating, cooling, fan and lighting energy. This paper discusses the overall energy use intensity of various external shading systems for a prototypical large office building split into the different types of energy use and for different orientations and window sizes. Lighting energy was calculated for a constant lighting power as well as for dimmed lighting fixtures (daylighting control). In Section 3, slat angles and solar cut-off angles were varied for fixed exterior slat shading systems. While the most light-blocking shades performed best for the case without daylighting controls, the optimum cut-off angle with daylighting controls was found to be 30 deg for the office building prototype used in Chicago and Houston. For large window-to-wall (WWR) ratios, window related annual energy use could be reduced by at least 70 % without daylighting control and by a minimum of 86 % with daylighting control in average over all orientations. The occurrence of discomfort glare was is considered in Section 4 of the paper, which looks at the performance of commercially available exterior shading systems when an interior shade is used in addition to the exterior shade during hours when occupants would experience discomfort glare. Glare control impacts overall energy use intensity significantly for exterior shades with high transmittance, especially when daylighting controls are used. In these cases, exterior shades are only beneficial for window-to-wall areas ≥ 45% in the hot Houston climate. For smaller windows and in a heating/cooling climate like Chicago, exterior shades can increase energy consumption

  20. Gas-fired chiller-heaters as a central plant alternative for small office buildings

    SciTech Connect (OSTI)

    Thies, R.M.; Bahnfleth, W.

    1998-01-01

    Gas absorption chillers-heaters have been applied successfully in large projects where use of multiple chillers is feasible. Large facilities typically have a substantial base cooling load. If the base load is greater than 30% of the minimum capacity of the smallest chiller, chiller-heaters alone can be used as the building central plant. However, this study shows that a small office building presents part-load design difficulties that tend to favor the use of other technologies. The engineer can overcome these application problems by a variety of means, as has been illustrated. Manufacturers, too, are addressing the problems associated with low-load operation of direct-fired chiller heaters. A new generation of chiller-heaters that can unload down to 10% of design load will soon be available. If these new machines are capital-cost-competitive and perform up to expectations, the routine application of chiller-heaters in small commercial buildings may be just around the corner.

  1. Office of Chief Financial Officer

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    fuel, and waste. The following factors present the strongest impacts to the overall achievement of the program's strategic goal: * Deferral of scheduled scope to stabilize, treat,...

  2. Office of Chief Financial Officer

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    high optical accuracy reflectors, reduce collector structure weight and material, develop lean and rapid methods for manufacturing, assembly and installation, develop highly...

  3. Office of Chief Financial Officer

    Broader source: Energy.gov (indexed) [DOE]

    ... sciences, advanced computing, and the basic sciences underpinning fossil energy, electricity delivery and reliability, nuclear energy, and energy efficiency and renewable energy. ...

  4. Office of Chief Financial Officer

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Transporation

  5. Office of Chief Financial Officer

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    FY 2017 Congressional Budget Justification Volume 3 Table of Contents Page Appropriation Account Summary ............................................................................................................................................ 1 Energy Efficiency and Renewable Energy ................................................................................................................................ 3 Electricity Delivery & Energy Reliability

  6. Office of Chief Financial Officer

    Broader source: Energy.gov (indexed) [DOE]

    3 DOECF-0098 Volume 3 Department of Energy FY 2015 Congressional Budget Request Energy Efficiency and Renewable Energy Electricity Delivery and Energy Reliability Nuclear Energy ...

  7. Office of Chief Financial Officer

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Volume 3 DOECF-0121 Volume 3 Department of Energy FY 2017 Congressional Budget Request Energy Efficiency and Renewable Energy Electricity Delivery and Energy Reliability Nuclear ...

  8. Office of Chief Financial Officer

    Energy Savers [EERE]

    Energy Budget by Appropriation Energy and Water Development, and Related Agencies Energy ... Federal Energy Regulatory Commission 0 0 0 0 0 NA Subtotal, Energy and Water Development ...

  9. Office of Chief Financial Officer

    Energy Savers [EERE]

    ... Energy Budget by Appropriation Energy and Water Development, and Related Agencies Energy ... Federal Energy Regulatory Commission 0 0 0 0 0 NA Subtotal, Energy and Water Development ...

  10. Office of Chief Financial Officer

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... that will consist of a mixture of classroom and project based practical experience. ... In addition, the Federal Energy Regulatory Commission (FERC) has mandated fair pricing for ...

  11. Office of Chief Financial Officer

    Energy Savers [EERE]

    ... undergraduate students to enter STEM careers especially ... and universities can then search for equipment of interest ... fall and spring semester terms, aligning CCI with SULI ...

  12. Office of Chief Financial Officer

    Energy Savers [EERE]

    ... upgrades continue to enter the design stage. * ... for both near and long terms insertion options to ... Team (JTOT) are to search for, identify, ...

  13. Office of Chief Financial Officer

    Energy Savers [EERE]

    ... are established by the terms of the ITER Joint ... spectroscopic experiments enter fabrication, specifically ... Axion Dark Matter Search Generation 2 (ADMX-G2), ...

  14. Office of Chief Financial Officer

    Energy Savers [EERE]

    OMB Requirements OMB Requirements Acquisitions OMB Circular A-109, Acquisition of Major Systems (04-05-76) (Available in hard copy only) OMB M-04-08, Maximizing Use of SmartBuy and Avoiding Duplication of Agency Activities with with the President's 24 E-Gov Initiatives (02-25-2004) (pdf) OMB M-04-16, Software Acquisition (07-01-2004) Budget/Capital Planning OMB Circular A-11 OMB M-05-23, Improving Informational Technology (IT) Project Planning and Execution (8-04-2005) (pdf) Cyber Security &

  15. Office of Chief Financial Officer

    Energy Savers [EERE]

    ... The crosscut seeks to reduce the cost and risk of geothermal development, by targeting R&D ... Additionally, FY 2017 funding will expand temperature-gradient well drilling under the ...

  16. Office of Inspector General audit report on the U.S. Department of Energy`s consolidated financial statements for fiscal year 1998

    SciTech Connect (OSTI)

    1999-02-01

    The Department prepared the Fiscal Year 1998 Accountability Report to combine critical financial and program performance information in a single report. The Department`s consolidated financial statements and the related audit reports are included as major components of the Accountability Report. The Office of Inspector General audited the Department`s consolidated financial statements as of and for the years ended September 30, 1998 and 1997. In the opinion of the Office of Inspector General, except for the environmental liabilities lines items in Fiscal year 1998, these financial statements present fairly, in all material respects, the financial position of the Department as of September 30, 1998 and 1997, and its consolidated net cost, changes in net position, budgetary resources, financing activities, and custodial activities for the years then ended in conformity with Federal accounting standards. In accordance with Government Auditing Standards, the Office of Inspector General issued a separate report on the Department internal controls. This report discusses needed improvements to the environmental liabilities estimating process and the reporting of performance measure information.

  17. Small Buildings = Big Opportunity for Energy Savings (Fact Sheet), Building Technologies Office (BTO), Energy Efficiency & Renewable Energy (EERE)

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Buildings = Big Opportunity for Energy Savings There is nothing small about the impact that small commercial buildings have on energy use in the United States. In fact, the 4.6 million small buildings across the nation consume 44% of the overall energy use in buildings, presenting an enormous opportunity to cut costs, energy use, and greenhouse gas emissions. Despite this potential, small building owners and operators face unique challenges that have historically impeded the adoption of

  18. Energy Savings Potential of Flexible and Adaptive HVAC Distribution Systems for Office Buildings

    SciTech Connect (OSTI)

    Loftness, Vivian; Brahme, Rohini; Mondazzi, Michelle; Vineyard, Edward; MacDonald, Michael

    2002-06-01

    It has been understood by architects and engineers that office buildings with easily re-configurable space and flexible mechanical and electrical systems are able to provide comfort that increases worker productivity while using less energy. Raised floors are an example of how fresh air, thermal conditioning, lighting needs, and network access can be delivered in a flexible manner that is not ''embedded'' within the structure. What are not yet documented is how well these systems perform and how much energy they can save. This area is being investigated in phased projects of the 21st Century Research Program of the Air-conditioning and Refrigeration Technology Institute. For the initial project, research teams at the Center for Building Performance and Diagnostics, Pittsburgh, Pennsylvania, and Oak Ridge National Laboratory, Oak Ridge, Tennessee, documented the diversity, performance, and incidence of flexible and adaptive HVAC systems. Information was gathered worldwide from journal and conference articles, case studies, manufactured products and assemblies, and interviews with design professionals. Their report thoroughly describes the variety of system types along with the various design alternatives observed for plenums, diffusers, individual control, and system integration. Many of the systems are illustrated in the report and the authors provide quantitative and qualitative comparisons. Among conclusions regarding key design issues, and barriers to widespread adoption, the authors state that flexible and adaptive HVAC systems, such as underfloor air, perform as well if not better than ceiling-based systems. Leading engineers have become active proponents after their first experience, which is resulting in these flexible and adaptive HVAC systems approaching 10 percent of the new construction market. To encourage adoption of this technology that improves thermal comfort and indoor air quality, follow-on work is required to further document performance

  19. FY 2014 Continuation of Solicitation for the Office of Science Financial Assistance Program

    SciTech Connect (OSTI)

    Saundry, Peter

    2014-04-01

    On January 28-30, 2014, the National Council for Science and the Environment (NCSE) hosted its 14th National Confrerence and Global Forum on Science, Policy and the Environment: Building Climate Solutions. The conference was held at the Hyatt Regency Crystal City near the Washington, DC National Airport. The conference engaged over 1,100 key individuals from a variety of fields, including natural and social sciences, humanities and engineering and government and policy, as well as business and civil society. They developed actionable partnerships, strategies and tactics that advanced solutions minimizing the impacts of anthropogenic climate change. The conference was organized around the two major areas where climate actions are necessary: [1] The Built Environment; and, [2] Agriculture and Natural Resources. This “multi-sector approach” of the conference enables participants to work across traditional boundaries of discipline, science, policy and application by engaging a diverse team of scientists, public- and private-sector program managers, and policy-makers. The confernce was two and a half days long. During this time, over 200 speakers presented in 8 keynote addresses, 7 plenary roundtable discussions, 30 symposia and 23 workshops. The goal of the workshops was to generate additional action through development of improved strategies, tools, and partnerships. During the workshops, participants developed actionable outcomes, committed to further collaboration and implementation, and outlined follow-up activities for post-conference. A list of recommendations from the workshop follows this summary. NCSE’s annual conference has become a signature event for the organization, recognized for its notable presenters, innovative programming, and outcome-oriented approach. Each year, over 1,100 participants attend the event, representing federal agencies, higher education institutions, state and local governments, non-governmental and civic organizations

  20. Controlling Capital Costs in High Performance Office Buildings: A Review of Best Practices for Overcoming Cost Barriers

    SciTech Connect (OSTI)

    Pless, S.; Torcellini, P.

    2012-05-01

    This paper presents a set of 15 best practices for owners, designers, and construction teams of office buildings to reach high performance goals for energy efficiency, while maintaining a competitive budget. They are based on the recent experiences of the owner and design/build team for the Research Support Facility (RSF) on National Renewable Energy Facility's campus in Golden, CO, which show that achieving this outcome requires each key integrated team member to understand their opportunities to control capital costs.

  1. Controlling Capital Costs in High Performance Office Buildings: A Review of Best Practices for Overcoming Cost Barriers

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Controlling Capital Costs in High Performance Office Buildings: A Review of Best Practices for Overcoming Cost Barriers Preprint Shanti Pless and Paul Torcellini To be presented at the ACEEE Summer Study on Energy Efficiency in Buildings Pacific Grove, California August 12-17, 2012 Conference Paper NREL/CP-5500-55264 May 2012 NOTICE The submitted manuscript has been offered by an employee of the Alliance for Sustainable Energy, LLC (Alliance), a contractor of the US Government under Contract No.

  2. US Department of Energy`s Federal Facility Compliance Act Chief Financial Officer`s Report to Congress for fiscal year 1993

    SciTech Connect (OSTI)

    Not Available

    1993-12-01

    The Federal Facility Compliance Act of 1992 (FFCAct) (Public Law 102-386) was enacted into law on October 6, 1992. In addition to amending the Resource Conservation and Recovery Act (RCRA), the FFCAct requires the US Department of Energy (DOE) to prepare an annual report from the Chief Financial Officer to the Congress on compliance activities undertaken by the DOE with regard to mixed waste streams and provide an accounting of the fines and penalties imposed upon the DOE for violations involving mixed waste. This document has been prepared to report the necessary information. Mixed waste is defined by the FFCAct to include those wastes containing both hazardous waste as defined in the RCRA and source, special nuclear, or byproduct material subject to the Atomic Energy Act of 1954, as amended (42 U.S.C. Section 2001 et seq.). Section 2 of this report briefly summarizes DOE Headquarters` activities conducted during Fiscal Year 1993 (FY 1993) to comply with the requirements of the FFCAct. Section 3 of this report provides an overview of the site-specific RCRA compliance activities, relating to mixed waste streams, conducted in FY 1993 for those sites that currently generated or store mixed waste that are subject to regulation under RCRA. Section 4 provides information on notifications of alleged RCRA violations involving mixed waste imposed upon the DOE during FY 1993 and an accounting of any fines and penalties associated with these violations. Appendix A provides site-specific summaries of RCRA compliance activities, relating to mixed waste streams, conducted in FY 1993 for those sites that currently generate or store mixed waste that are subject to regulation under RCRA.

  3. Federal Financial Report

    Broader source: Energy.gov [DOE]

    Federal Financial Report, as posted on the U.S. Department of Energy's Better Buildings Neighborhood Program website.

  4. Professional","Government ","All Other Office"

    U.S. Energy Information Administration (EIA) Indexed Site

    ,"All Buildings*","Office Buildings" ,,"All Office","Administrative Professional","Government ","All Other Office" "All Buildings",64783,12208,6628,1549,4031 "Building...

  5. Professional","Government ","All Other Office"

    U.S. Energy Information Administration (EIA) Indexed Site

    ,"All Buildings*","Office Buildings" ,,"All Office","Administrative Professional","Government ","All Other Office" "All Buildings",4645,824,442,84,298 "Building Floorspace"...

  6. US Department of Energy Grand Junction Projects Office Remedial Action Project, final report of the decontamination and decommissioning of Building 36 at the Grand Junction Projects Office Facility

    SciTech Connect (OSTI)

    Widdop, M.R.

    1996-08-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, also is the remedial action contractor. Building 36 was found to be radiologically contaminated and was demolished in 1996. The soil beneath the building was remediated in accordance with identified standards and can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.

  7. Financial Opportunities | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Financial Opportunities Financial Opportunities The U.S. Department of Energy's (DOE) Fuel Cell Technologies (FCT) Office offers information about current and past funding ...

  8. Technical basis for radiological release of Grand Junction Office Building 2. Volume 2, dose assessment supporting data

    SciTech Connect (OSTI)

    1997-07-01

    The second volume of the Grand Junction Office Action Program Technical Basis for Radiological Release of Grand Junction Office Building 2 report includes the data quality objectives (DQO), sampling plan, collected data, and analysis used to model future radiation doses to members of the public occupying Building 2 on the U.S. Department of Energy (DOE) Grand Junction Office (GJO) site. This volume was assembled by extracting relevant components of the Grand Junction Projects Office Remedial Action Project Building 2 Public Dose Evaluation (DOE 1996) and inserting recent additional data that was gathered and dose pathway modeling that was performed. The intent of this document is to provide all derived guidance decisions, assumptions, measured data, testing results, and pathway modeling software input and output data that supports the discussion and determinations presented in Volume 1 of this report. For constructive employment of this document, the reader is encouraged to closely follow Volume 1 for proper association with the segment of information being examined.

  9. Contaminants in Buildings and Occupied Spaces as Risk Factors forOccupant Symptoms in U.S. Office Buildings: Findings from the U.S. EPABASE Study

    SciTech Connect (OSTI)

    Mendell, M.J.; Mirer, A.; Lei-Gomez, Q.

    2007-08-01

    Nonspecific building-related symptoms among occupants of modern office buildings worldwide are common and may be associated with important reductions in work performance, but their etiology remains uncertain. Most reported research into environmental risk factors for these symptoms has focused on ventilation system-related factors, dampness, and particle removal through filtration and cleaning, with relatively few studies of other potential sources of indoor contaminants. We analyzed data collected by the U.S. Environmental Protection Agency (EPA) from a representative sample of 100 large U.S. office buildings--the Building Assessment and Survey Evaluation (BASE) study--using multivariate-adjusted logistic regression models with generalized estimating equations. We estimated odds ratios (ORs) and 95% confidence intervals (CIs) for associations between seven building-related symptom outcomes and a diverse set of potential indoor and outdoor sources for indoor pollutants. Although most of the investigated risk factors showed no apparent association with building-related symptoms, some interesting associations resulted. Increased prevalence of symptoms was associated with carpets older than one year (lower respiratory symptoms), non-carpeted floors (upper and lower respiratory symptoms), older furniture (eye and skin symptoms), infrequent vacuuming (upper respiratory, eye, and skin symptoms and headache), and masonry exterior walls (cough, eye symptoms, and fatigue/concentration difficulty). For the many potential risk factors assessed, almost none had been investigated previously, and many associations found here may have been by chance. Additional confirmatory research focused on risk factors initially identified here is needed, using more objective measures of health outcomes and risk factors or exposures.

  10. Energy Efficient Buildings Hub

    Office of Energy Efficiency and Renewable Energy (EERE)

    Energy Efficient Buildings HUB Lunch Presentation for the 2013 Building Technologies Office's Program Peer Review

  11. Energy Efficient Buildings Hub

    SciTech Connect (OSTI)

    2013-04-01

    Energy Efficient Buildings HUB Lunch Presentation for the 2013 Building Technologies Office's Program Peer Review

  12. Building America System Research

    SciTech Connect (OSTI)

    2013-04-01

    Residential Buildings Integration Project for the 2013 Building Technologies Office's Program Peer Review

  13. OFFICE,

    Office of Legacy Management (LM)

    OFFICE, . . . . . ..-..__. _ --.-.__.. .-..I............ !..-... bUmME. wArl&l ' rrsldu*. in the dw6lopmQt pmgrwh : Be ostiamts Uuat not man lf+ .b%'o,Q~~~ds. cik'e%ah of the eevenl reel&~ will be require& In : 'ri~ofthehereiabefor6notedeopreodo~ of puriata~tio.aadap :, Iv ve unbntend you vi11 not obj.& to:tha aoe " ai spoh +ant+lea of the mirloua real&es ,, ', ',"" ': ., .,.. i. : /~. ,".. .I,: /, . . ' .* ,; ., ,' ,:.' . .-;. ,-Y .b4 P-0 : ,.

  14. Building Technologies Office: R&D Opportunities to Reduce Energy Consumption in Miscellaneous Electric Loads (MELs)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Office: R&D Opportunities to Reduce Energy Consumption in Miscellaneous Electric Loads (MELs) Pat Phelan (patrick.phelan@ee.doe.gov) BTO Emerging Technologies June 3, 2016 2 Why Do We Care About MELs? Problem: Fraction of energy consumption due to MELs is rising as other building technologies become more efficient. DOE Quadrennial Technology Review (2015)  60% of remaining energy consumption after 2020 R&D targets are achieved, the majority of which are MELs. FY16 Activities: * Panel

  15. Total heat gain and the split between radiant and convective heat gain from office and laboratory equipment in buildings

    SciTech Connect (OSTI)

    Hosni, M.H.; Jones, B.W.; Sipes, J.M.; Xu, Y.

    1998-10-01

    An accurate determination of the cooling load is important in the proper sizing of air-conditioning equipment. Improvements on the thermal insulation characteristics of building materials and recent advances in building envelope systems have reduced the building cooling load from external sources. However, the number of internal cooling load sources have increased due to the addition of various office and laboratory equipment (e.g., microcomputer, monitor, printer copier, scanner, overhead projector, microwave oven, incubator, etc.). In this article, typical office and laboratory equipment such as desktop computers (with a Pentium and a 486DX2-33 processor), monitors, a copier, a laser printer, and a biological incubator are evaluated to determine the total heat gain and the split between radiant and convective heat gain from these items. In addition, two standard objects with well-defined radiant heat loss characteristics, a heated flat slab, and a heated sphere are used to verify the accuracy of measurement and data reduction procedures. The total heat gain from tested office equipment was significantly less than the name plate ratings even when operated continuously. The actual power consumption ranged from 14% to 36% of the name plate ratings. Thus, care must be taken when using equipment nameplate ratings in estimating total heat gain for air-conditioning equipment sizing.

  16. Buildings

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Historically, only Industrial Facilities (ISO 50003 Industry - light to medium and ... is allowing Commercial Buildings (ISO 50003 - Buildings and Building Complexes) ...

  17. Steam System Balancing and Tuning for Multifamily Residential Buildings, Chicago, Illinois (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Steam System Balancing and Tuning for Multifamily Residential Buildings Chicago, Illinois PROJECT INFORMATION Project Name: Steam System Balancing and Tuning for Multifamily Residential Buildings Location: Chicago, IL Partners: Partnership for Advanced Residential Retrofit www.gastechnology.org Building Component: Steam heating distribution system and controls Application: Retrofit; Multifamily Year Tested: 2011-2012 Applicable Climate Zone(s): Cold humid continental PERFORMANCE DATA Cost of

  18. Vehicle Technologies Office Merit Review 2015: Clean Cities Coordinator Resource Building and National Networking Activities

    Office of Energy Efficiency and Renewable Energy (EERE)

    Presentation given by National Renewable Energy Laboratory at 2015 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about Clean...

  19. Vehicle Technologies Office Merit Review 2016: VTO Vehicle to Building Integration Pathway

    Broader source: Energy.gov [DOE]

    Presentation given by Pacific Northwest National Laboratory (PNNL) at the 2016 DOE Vehicle Technologies Office and Hydrogen and Fuel Cells Program Annual Merit Review and Peer Evaluation Meeting...

  20. Final report of the decontamination and decommissioning of Building 34 at the Grand Junction Projects Office Facility

    SciTech Connect (OSTI)

    Widdop, M.R.

    1996-08-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7 acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the Grand Junction Projects Office Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, was also the remedial action contractor. Building 34 was radiologically contaminated and the building was demolished in 1996. The soil area within the footprint of the building was analyzed and found to be not contaminated. The area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual closeout report for each contaminated GJPO building.

  1. Final report of the decontamination and decommissioning of Building 44 at the Grand Junction Projects Office Facility

    SciTech Connect (OSTI)

    Widdop, M.R.

    1996-07-01

    The U.S. Department of Energy (DOE) Junction Projects Office (GJPO) occupies a 61.7 acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the Grand Junction Projects Office Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, is also the remedial action contractor. Building 44 was radiologically contaminated and the building was demolished in 1994. The soil area within the footprint of the building was not contaminated; it complies with the identified standards and the area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.

  2. MEMORANDUM FOR THE DIRECTOR, OFFICE OF MANAGEMENT, BUDGET AND...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ... matters, we coordinated closely with the Office of Program Liaison and Financial Analysis. ... Financial: Performance: Financial Statement Economy and Efficiency Financial ...

  3. Building Technologies Office Window and Envelope Technologies Emerging Technologies R&D Program

    Broader source: Energy.gov (indexed) [DOE]

    The BPD statistically analyzes the energy performance and physical and operational characteristics of real commercial and residential buildings. The Building Performance Database offers two primary methods to analyze building performance data. These are "Explore", which allows users to browse a single dataset within the BPD, and "Compare", which allowed users to compare multiple datasets within the BPD side-by-side. Explore The Explore tool allows users to browse a single

  4. US Department of Energy Grand Junction Projects Office Remedial Action Project. Final report of the decontamination and decommissioning of Building 52 at the Grand Junction Projects Office Facility

    SciTech Connect (OSTI)

    Krabacher, J.E.

    1996-08-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, also was the remedial action contractor. Building 52 was found to be radiologically contaminated and was demolished in 1994. The soil area within the footprint of the building has been remediated in accordance with the identified standards and the area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.

  5. Seaborg and Kennedy in the AEC Building | U.S. DOE Office of...

    Office of Science (SC) Website

    Enlarge Photo Sample Horizontal Photo Dr. Seaborg and President Kennedy at the Atomic Energy Commission headquarters building, room A-445, in Germantown MD on February 16, 1961. ...

  6. Final report of the radiological release survey of Building 30B at the Grand Junction Office Facility

    SciTech Connect (OSTI)

    Krauland, P.A.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 30B and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building.

  7. Final Environmental Assessment for the construction and operation of an office building at the Stanford Linear Accelerator Center. Part 2

    SciTech Connect (OSTI)

    1995-08-01

    The Department of Energy (DOE) has prepared an Environmental Assessment (EA), DOE/EA-1107, analyzing the environmental effects relating to the construction and operation of an office building at the Stanford Linear Accelerator Center (SLAC). SLAC is a national facility operated by Stanford University, California, under contract with DOE. The center is dedicated to research in elementary particle physics and in those fields that make use of its synchrotron facilities. The objective for the construction and operation of an office building is to provide adequate office space for existing SLAC Waste Management (WM) personnel, so as to centralize WM personnel and to make WM operations more efficient and effective. Based on the analyses in the EA, the DOE has determined that the proposed action does not constitute a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act of 1969 (NEPA). Therefore, the preparation of an Environmental Impact Statement is not required. This report contains the Environmental Assessment, as well as the Finding of No Significant Impact (FONSI).

  8. Vehicle Technologies Office Merit Review 2016: VTO Diagnostic Security Modules for Electric Vehicle to Building Integration

    Broader source: Energy.gov [DOE]

    Presentation given by Idaho National Laboratory (INL) at the 2016 DOE Vehicle Technologies Office and Hydrogen and Fuel Cells Program Annual Merit Review and Peer Evaluation Meeting about Vehicle...

  9. Current Financial Opportunities

    Broader source: Energy.gov [DOE]

    Current hydrogen-related funding opportunities through the U.S. Department of Energy's (DOE) Fuel Cell Technologies Office are listed below. The Fuel Cell Technologies Office offers opportunities for both financial and technical assistance.

  10. Seaborg and Kennedy in the AEC Building | U.S. DOE Office of Science (SC)

    Office of Science (SC) Website

    in the AEC Building Basic Energy Sciences (BES) BES Home About Organization Chart .pdf file (132KB) Staff BES Budget BES Committees of Visitors Directions Jobs Organizational History Germantown Natural History President Kennedy's AEC Briefings Research Facilities Science Highlights Benefits of BES Funding Opportunities Basic Energy Sciences Advisory Committee (BESAC) Community Resources Contact Information Basic Energy Sciences U.S. Department of Energy SC-22/Germantown Building 1000

  11. Final report of the decontamination and decommissioning of Building 39 at the Grand Junction Projects Office Facility

    SciTech Connect (OSTI)

    Widdop, M.R.

    1996-07-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, is also the remedial action contractor. The soil beneath Building 39 was radiologically contaminated and the building was demolished in 1992. The soil area within the footprint of the building has been remediated in accordance with the identified standards and the area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.

  12. Final report of the decontamination and decommissioning of Building 6 at the Grand Junction Projects Office Facility

    SciTech Connect (OSTI)

    Widdop, M.R.

    1996-07-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the domestic uranium procurement program funded by the U.S. Atomic Energy Commission. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, is also the remedial action contractor. Radiological contamination was identified in Building 6, and the building was demolished in 1992. The soil area within the footprint of the building has been remediated in accordance with the identified standards and the area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.

  13. Final report of the decontamination and decommission of Building 31 at the Grand Junction Projects Office Facility

    SciTech Connect (OSTI)

    Krabacher, J.E.

    1996-07-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the domestic uranium procurement program funded by the U.S. Atomic Energy Commission. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, also was the remedial action contractor. Radiological contamination was identified in Building 31 and the building was demolished in 1992. The soil area within the footprint of the building has been remediated in accordance with the identified standards and the area can be released for unlimited exposure and unrestricted use. This area was addressed in the summary final report of the remediation of the exterior areas of the GJPO facility. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.

  14. Final report of the decontamination and decommissioning of Building 18 at the Grand Junction Projects Office Facility

    SciTech Connect (OSTI)

    Widdop, M.R.

    1996-08-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, also is the remedial action contractor. The soil beneath Building 18 was found to be radiologically contaminated; the building was not contaminated. The soil was remediated in accordance with identified standards. Building 18 and the underlying soil can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.

  15. CMTA Office

    High Performance Buildings Database

    Prospect, KY When CMTA outgrew their old office space, the consultant engineering company decided to construct a new building. Not only does the structure provide offices for the firm, it also showcases progressive design elements and allows the firm to test new technologies and demonstrate their effectiveness to clients. The new CMTA office building is located in a live-work development on the outskirts of Louisville, KY. The location was selected to place the office close to where the employees live.

  16. All Office Administrative/ Professional Government All Other

    U.S. Energy Information Administration (EIA) Indexed Site

    Buildings Energy Consumption Survey All Office Administrative Professional Government All Other Office All Buildings... 4,645 824 442 84...

  17. All Office Administrative/ Professional Government All Other

    U.S. Energy Information Administration (EIA) Indexed Site

    Buildings Energy Consumption Survey All Office Administrative Professional Government All Other Office All Buildings... 64,783 12,208...

  18. SEP Success Story: Delaware Company Breathes New Life into Old Post Office Building

    Broader source: Energy.gov [DOE]

    With the help of the Energy Department’s State Energy Program, Brandywine CAD Design, Inc. set out to create a new workspace. The long-term goal: qualify for the U.S. Green Building Council’s Leadership in Energy and Environmental Design (LEED) Platinum rating -- something that they hope to achieve by mid 2014. Learn more.

  19. Consumer decision and behavior research agenda for the Office of Building and Community Systems

    SciTech Connect (OSTI)

    Mohler, B.L.; Scheer, R.M.; Barnes, V.

    1985-12-01

    This report presents a research agenda of Consumer Decision and Behavior Projects related to improving, facilitating and planning Building and Community Systems, (BCS) research and development activities. Information for developing this agenda was gathered through focus group and depth interviews with BCS staff, directors and program managers.

  20. Final report of the decontamination and decommissioning of Building 1 at the Grand Junction Projects Office Facility

    SciTech Connect (OSTI)

    Widdop, M.R.

    1996-08-01

    The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, also is the remedial action contractor. Building 1 was found to be radiologically contaminated and was demolished in 1996. The soil beneath and adjacent to the building was remediated in accordance with identified standards and can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.

  1. Tribal Financial Management Symposium

    Broader source: Energy.gov [DOE]

    The 3rd Annual Tribal Financial Management Symposium is a two-day event will focus on one of the most important aspects of a tribe's financial management. Attendees will learn about the state of the economy, building a financial constitution, both long- and short-term investments, alternative investment options, and much more.

  2. Financial Assistance | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Assistance Financial Assistance Financial Assistance Regulations Governmentwide Uniform Regulations for Financial Assistance (Omnicircular; Issued 12/26/2013) DOE Financial Assistance Regulations (which Implement and Amend the Omnicircular; Issued 12/19/2014) New Restrictions on Lobbying, 10 CFR Part 601 Epidemiology & Other Health Studies, 10 CFR Part 602 Technology Investment Agreements, 10 CFR 603 Office of Science Financial Assistance Program, 10 CFR Part 605 Previous Financial

  3. BLM Nevada State Office | Open Energy Information

    Open Energy Info (EERE)

    Office Jump to: navigation, search Logo: BLM Nevada State Office Name: BLM Nevada State Office Abbreviation: Nevada Address: 1340 Financial Blvd Place: Reno, NV Zip: 89502 Phone...

  4. Buildings Energy Data Book: 9.1 ENERGY STAR

    Buildings Energy Data Book [EERE]

    3 ENERGY STAR Commercial and Institutional Buildings and Industrial Plants (1) Building Type 1999 Office 2000 K-12 School 2001 Retail 2002 Hospital (General and Surgical) 2003 Supermarket/Grocery 2004 Hotel 2005 Bank/Financial Institution 2006 Warehouse (Unrefrigerated) 2007 Courthouse 2008 Medical Office 2009 Residence Hall/Dormitory 2010 Senior Care Facility 2011 Data Center Total (2) Warehouse (Refrigerated) House of Worship Industrial Plants Total Note(s): Source(s): 1) Data as of February

  5. WNR Offices

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Offices, Experimental Areas, Buildings, and Contacts Description Contact Name Bldg/Room Phone Pager/Alt. Phone Group Office Julie Quintana 622/220 667-5377 665-5390 User Office Tanya Herrera 622/212 667-6797 MPF-31 Building Manager Kenny Madrid 31/125 665-0944 664-8327 MPF-17 Building Manager Gene Cartelli 6/133 667-2127 664-4234 MPF-7 Building Manager Bruce Wheeler 622/248 667-6715 664-8336 Property Julie Martinez 24/110 665-2058 664-6775 Waste Manager Lance Kloefkorn 6/236 665-3288 664-5972

  6. Building Envelope Stakeholder Workshop

    Broader source: Energy.gov [DOE]

    Oak Ridge National Laboratory is hosting a building envelope stakeholder workshop on behalf of the DOE Building Technologies Office.

  7. Building

    U.S. Energy Information Administration (EIA) Indexed Site

    DIV. Electricity Consumption and Expenditure Intensities by Census Division, 1999" ,"Electricity Consumption",,,"Electricity Expenditures" ,"per Building (thousand kWh)","per...

  8. The Advantage of Highly Controlled Lighting for Offices and Commercial Buildings

    SciTech Connect (OSTI)

    Rubinstein, Francis; Bolotov, Dmitriy; Levi, Mark; Powell, Kevin; Schwartz, Peter

    2008-08-17

    The paper presents results from pilot studies of new 'workstation-specific' luminaires that are designed to provide highly, efficient, customized lighting for open-office cubicles. Workstation specific luminaires have the following characteristics: (1) they provide separate, dimming control of the cubicle's 'ambient' and 'task' lighting components, (2) occupancy sensors and control photosensors are integrated into the fixture's design and operation, (3) luminaires can be networked using physical cabling, microcontrollers and a PC running control software. The energy savings, demand response capabilities and quality of light from the two WS luminaires were evaluated and compared to the performance of a static, low-ambient lighting system that is uncontrolled. Initial results from weeks of operation provide strong indication that WS luminaires can largely eliminate the unnecessary lighting of unoccupied cubicles while providing IESNA-required light levels when the cubicles are occupied. Because each cubicle's lighting is under occupant sensor control, the WS luminaires can capitalize on the fact cubicles are often unoccupied during normal working hours and reduce their energy use accordingly.

  9. Reducing Data Center Loads for a Large-Scale, Net Zero Office Building (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2011-12-01

    Case study highlighting the design, implementation strategies, and continuous performance monitoring of NREL's Research Support Facility data center. In constructing a new research facility for its campus, the National Renewable Energy Laboratory (NREL) project team identified the opportunity to design a world-class, energy-efficient data center to support its operations. NREL's efforts resulted in a highly efficient data center that demonstrated considerable energy savings in its first 11 months of operations. Using legacy data center performance as a baseline, the new facility cut energy use by nearly 1,450,000 kWh, delivering cost savings of approximately $82,000. The data center's average total load was 165 kW less than the legacy center's average total load, resulting in a 60% reduction in overall power. Finally, the limited use of cooling and fan energy enabled the new data center to achieve a 1.16 average power utilization effectiveness (PUE) rating, compared to the legacy data center's PUE of 2.28. The laboratory had been relying on individual servers with an energy utilization rate of less than 5%. NREL employed building best practices, innovative design techniques and energy-efficient technologies to support its energy goals for the new data center. To counteract the extensive heat generated by data center equipment, the laboratory implemented a cooling system using outdoor air and evaporative cooling to meet most of the center's needs. Inside the data center, NREL replaced much of its legacy equipment with new, energy-efficient technology. By exchanging this infrastructure for virtualized blade servers, NREL reduced its server energy footprint by 96%. Additionally, NREL replaced its 80%-efficient uninterruptible power supply (UPS) with a UPS that is 95% efficient; deployed ultra efficient power distribution units (PDU) to handle higher UPS voltages; and implemented vacancy sensors to drive down lighting loads. Using best practices and energy

  10. Building.

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Plant in ITER refers to plant systems located outside the Tokamak Building. A thick wall ... The cooling water system provides for the rejection of heat from a variety of ITER systems ...